WorldWideScience

Sample records for detect multi-vessel coronary

  1. Higher incidence of death in multi-vessel coronary artery disease patients associated with polymorphisms in chromosome 9p21

    Directory of Open Access Journals (Sweden)

    Gioli-Pereira Luciana

    2012-08-01

    scenarios. In patients with established CAD, we observed an association between the rs2383206 and higher incidence of overall mortality and death from cardiac causes in patients with multi-vessel CAD.

  2. Comparing treatment outcomes of fractional flow reserve-guided and angiography-guided percutaneous coronary intervention in patients with multi-vessel coronary artery diseases: a systematic review and meta-analysis.

    Science.gov (United States)

    Xiu, Jiancheng; Chen, Gangbin; Zheng, Hua; Wang, Yuegang; Chen, Haibin; Liu, Xuewei; Wu, Juefei; Bin, Jianping

    2016-02-01

    Fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) is used to assess the need for angioplasty in vessels with intermediate blockages. The treatment outcomes of FFR-guided vs. conventional angiography-guided PCI were evaluated in patients with multi-vessel coronary artery disease (CAD). Prospective and retrospective studies comparing FFR-guided vs. angiography-guided PCI in patients with multi-vessel CAD were identified from medical databases by two independent reviewers using the terms "percutaneous coronary intervention, fractional flow reserve, angiography, coronary heart disease, major adverse cardiac events (MACE) and myocardial infarction". The primary outcome was the number of stents placed, and the secondary outcomes were procedure time, mortality, myocardial infarction (MI) and MACE rates. Seven studies (three retrospective and four prospective), which included 49,517 patients, were included in this review. A total of 4,755 patients underwent FFR, while 44,697 received angiography-guided PCI. The mean patient age ranged from 58 to 71.7 years. The average number of stents used in FFR patients ranged from 0.3-1.9, and in angiography-guided PCI patients ranged from 0.7-2.7. Analysis indicated there was a greater number of stents placed in the angiography-guided group compared with the FFR group (pooled difference in means: -0.64, 95% confidence interval [CI]: -0.81 to -0.47, P < 0.001). There were no differences in the secondary outcomes between the two groups. Both procedures produce similar clinical outcomes, but the fewer number of stents used with FFR may have clinical as was as cost implications.

  3. Complete versus culprit-only revascularisation in ST elevation myocardial infarction with multi-vessel disease

    DEFF Research Database (Denmark)

    Bravo, Claudio A.; Hirji, Sameer A.; Bhatt, Deepak L.

    2017-01-01

    Background: Multi-vessel coronary disease in people with ST elevation myocardial infarction (STEMI) is common and is associated with worse prognosis after STEMI. Based on limited evidence, international guidelines recommend intervention on only the culprit vessel during STEMI. This, in turn, leaves...

  4. Resting 123I-BMIPP scintigraphy for detection of organic coronary stenosis and therapeutic outcome in patients with chest pain

    International Nuclear Information System (INIS)

    Yamabe, Hiroshi; Fujiwara, Sei; Rin, Kouten; Ando, Makoto; Yokoyama, Mitsuhiro; Sakamoto, Takaaki; Ishida, Toshiharu; Itagane, Hiroshi; Mori, Takao

    2000-01-01

    Resting 123 I-BMIPP scintigraphy can detect coronary artery disease based on persistent abnormality of myocardial fatty acid metabolism after transient ischemia. The present study aimed to determine the value of resting 123 I-BMIPP scintigraphy in diagnosing coronary artery disease and predicting the therapeutic outcome in patients with chest pain symptom. Five hospitals participated in this study, and scintigraphic and angiographic studies were performed in 104 patients without myocardial infarction. Twenty of them had non-coronary artery disease (chest pain syndrome), 26 had stable effort angina, 35 had unstable angina with organic coronary lesions, and 23 had vasospastic angina without significant organic stenosis. Overall sensitivity for diagnosing angina pectoris (stable, unstable and vasospastic) was 45%, and overall specificity for excluding non-coronary artery disease was 80%. The incidence of positive 123 I-BMIPP was 54% among patients with organic coronary stenosis (50% in stable angina and 61% in unstable angina with organic stenosis), but it was low (22%) in vasospastic angina without organic stenosis. Patients with advanced coronary stenosis and multi-vessel disease were found to have a higher incidence of positive 123 I-BMIPP. A positive 123 I-BMIPP result was correlated with a higher rate of subsequent intervention therapy (catheter intervention or CABG) than a negative result (48% versus 27%, p=0.03 at one month; and 63% versus 35%, p=0.008 at one year). Resting 123 I-BMIPP scintigraphy was valuable in detecting advanced coronary lesions in angina patients associated with a high incidence of subsequent intervention therapy. (author)

  5. Detection of coronary calcification in ultrafast CT compared to coronary angiography

    International Nuclear Information System (INIS)

    Koesling, S.; Hoffmann, U.; Rother, T.; Lieberenz, S.; Heywang-Koebrunner, S.H.; Schulz, H.G.

    1994-01-01

    The angiographical findings of 24 patients with coronary artery disease were compared with qualitative and quantitative detection of coronary calcification by ultrafast CT. Doubts concerning the capabilities of the ultrafast CT for a screening of coronary artery disease arise when the results of one third false positive and fase negative findings are considered. Variations in the quantification of coronary calcification were too great to allow a realistic assessment of the degree of stenosis of the coronary arteries. (orig.) [de

  6. [Development of an automated processing method to detect coronary motion for coronary magnetic resonance angiography].

    Science.gov (United States)

    Asou, Hiroya; Imada, N; Sato, T

    2010-06-20

    On coronary MR angiography (CMRA), cardiac motions worsen the image quality. To improve the image quality, detection of cardiac especially for individual coronary motion is very important. Usually, scan delay and duration were determined manually by the operator. We developed a new evaluation method to calculate static time of individual coronary artery. At first, coronary cine MRI was taken at the level of about 3 cm below the aortic valve (80 images/R-R). Chronological change of the signals were evaluated with Fourier transformation of each pixel of the images were done. Noise reduction with subtraction process and extraction process were done. To extract higher motion such as coronary arteries, morphological filter process and labeling process were added. Using these imaging processes, individual coronary motion was extracted and individual coronary static time was calculated automatically. We compared the images with ordinary manual method and new automated method in 10 healthy volunteers. Coronary static times were calculated with our method. Calculated coronary static time was shorter than that of ordinary manual method. And scan time became about 10% longer than that of ordinary method. Image qualities were improved in our method. Our automated detection method for coronary static time with chronological Fourier transformation has a potential to improve the image quality of CMRA and easy processing.

  7. Edge detection versus densitometry for assessing coronary stenting quantitatively

    NARCIS (Netherlands)

    B.H. Strauss (Bradley); Y. Juilliere; B.J.W.M. Rensing (Benno); J.H.C. Reiber (Johan); P.W.J.C. Serruys (Patrick)

    1991-01-01

    textabstractThe optimal method used to analyze quantitatively the immediate angiographic results of coronary stenting in the coronary arteries has not been studied. Accordingly, minimal luminal cross-sectional area was determined by 2 methods, edge detection and densitometry, in 19 patients who

  8. Left coronary arterial blood flow: Noninvasive detection by Doppler US

    International Nuclear Information System (INIS)

    Gramiak, R.; Holen, J.; Moss, A.J.; Gutierrez, O.H.; Picone, A.L.; Roe, S.A.

    1986-01-01

    Continuous wave (CW) and pulsed Doppler ultrasound studies with spectral analysis were used to detect the left coronary arterial blood flow in patients who were undergoing routine echocardiography. The pulmonary artery is a stable ultrasonic landmark from which detection of the blood flow can be effected. The left coronary artery can be distinguished by its blood flow toward the cardiac apex and by specific, functional flow features. Flow patterns vary among the left main, circumflex, and anterior descending arteries; patterns also vary with respiration cycles. In the present study, coronary arterial blood flow was detected in 58 of 70 patients (83%). Findings were validated by selectively injecting an agitated saline contrast medium into the left coronary artery and, in another study, by comparing human Doppler phasic flow waveforms with electromagnetic flowmeter recordings obtained in dogs

  9. Prognosis of non-significant coronary atherosclerotic disease detected by coronary artery tomography

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Marcio Vinicius Lins; Siqueira, Bruna Pinto; Guimaraes, Carolina Camargos Braichi; Cruz, David Filipe Silva; Guimaraes, Leiziane Assuncao Alves; Lima, Maicom Marcio Perigolo, E-mail: marciovlbarros@gmail.com [Faculdade de Saude e Ecologia Humana, Vespasiano, MG (Brazil); Nunes, Maria do Carmo Pereira [Universidade de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Medicina; Siqueira, Maria Helena Albernaz [Hospital Materdei, Belo Horizonte, MG (Brazil)

    2015-07-15

    Introduction: Although studies have shown high diagnostic accuracy of coronary tomography (CT) in detecting coronary artery disease (CAD), data on the prognostic value of this method in patients with no significant coronary obstruction are limited. Objective: To evaluate the value of CT in predicting adverse events in patients with suspected CAD and no significant coronary obstruction. Methods: We prospectively evaluated 440 patients between January 2008 and July 2013 by MDCT, diagnosed with no significant obstruction or no atherosclerotic coronary obstruction with an average follow-up of 33 months. The outcomes evaluated were: cardiac death, myocardial infarction, unstable angina associated with hospitalization or coronary artery bypass grafting. Results: Of the 440 patients studied, 295 (67%) were men with mean age 55.9 ± 12.0 years. Non-significant obstruction was found in 152 (35%) of the patients and there were 49 (11%) outcomes. In the multivariate analysis using the Cox regression model, the predictors of clinical outcomes were non-significant obstruction on CT (hazard ratio 3.51; 95% CI 1.73 - 7.8; p <0.01), age and hypertension. Non-significant obstruction on CT was associated with adverse clinical outcomes and survival analysis showed a significant difference (log-rank 24.6; p <0.01) in predicting these outcomes. Conclusion: The detection of non-significant atherosclerotic obstruction by CT was associated with the presence of adverse events in patients with suspected CAD, which may prove useful in the risk stratification of these patients. (author)

  10. Detecting asymptomatic coronary artery disease using routine ...

    African Journals Online (AJOL)

    ECG-monitored exercise testing has been proposed as a relatively inexpensive and effective means of screening for asymptomatic coronary artery disease in patients presenting for peripheral vascular surgery. Despite the fact that exercise thallium scintigraphy is also dependent on the patient's ability to exercise, using this ...

  11. [Comparison of 64 MDCT coronary CTA and coronary angiography in the detection of coronary artery stenosis in low risk patients with stable angina and acute coronary syndrome].

    Science.gov (United States)

    Cazalas, G; Sarran, A; Amabile, N; Chaumoitre, K; Marciano-Chagnaud, S; Jacquier, A; Paganelli, F; Panuel, M

    2009-09-01

    To determine the accuracy of 64 MDCT coronary CTA (CCTA) compared to coronary angiography in low risk patients with stable angina and acute coronary syndrome and determine the number of significant coronary artery stenoses ( 50%) in these patients. Materials and methods. Fifty-five patients underwent CCTA using a 32 MDCT unit with z flying focus allowing the acquisition of 64 slices of 0.6 mm thickness as well as coronary angiography (gold standard). Nine patients were excluded due to prior coronary artery bypass surgery (n=4), insufficient breath hold (n=3), calcium scoring>1000 (n=1) and delay between both examinations over 4 months (n=1). Forty-six patients: 27 males and 19 females were included. CCTA results were compared to coronary angiography per segment and artery with threshold detection of stenoses 50%. The degree of correlation between both examinations was performed using a regression analysis with a Pearson correlation coefficient<0.05 considered significant. The overall accuracy of CCTA was 90%; limitations related to the presence of calcifications, motion artifacts or insufficient vessel opacification. The correlation for all analyzed segments was 96.4%. Thirty-eight of 50 significant stenoses seen on coronary angiography were correctly detected on CCTA. Sensitivity, specificity, PPVC and NPV for detection of stenoses 50% were 76%, 98.3%, 80.3% and 97.7% respectively. Evaluation per segment had a NPV of 96.8% (interventricular and diagonal segments) to 100% (main trunk). Our results for specificity and NPV are similar to reports from the literature. This suggests that CCTA in this clinical setting may replace coronary angiography.

  12. Robust simultaneous detection of coronary borders in complex images

    International Nuclear Information System (INIS)

    Sonka, M.; Winniford, M.D.; Collins, S.M.

    1995-01-01

    Visual estimation of coronary obstruction severity from angiograms suffers from poor inter- and intraobserver reproducibility and is often inaccurate. In spite of the widely recognized limitations of visual analysis, automated methods have not found widespread clinical use, in part because they too frequently fail to accurately identify vessel borders. The authors have developed a robust method for simultaneous detection of left and right coronary borders that is suitable for analysis of complex images with poor contrast, nearby or overlapping structures, or branching vessels. The reliability of the simultaneous border detection method and that of their previously reported conventional border detection method were tested in 130 complex images, selected because conventional automated border detection might be expected to fail. Conventional analysis failed to yield acceptable borders in 65/130 or 50% of images. Simultaneous border detection was much more robust (p < .001) and failed in only 15/130 or 12% of complex images. Simultaneous border detection identified stenosis diameters that correlated significantly better with observer-derived stenosis diameters than did diameters obtained with conventional border detection (p < 0.001). Simultaneous detection of left and right coronary borders is highly robust and has substantial promise for enhancing the utility of quantitative coronary angiography in the clinical setting

  13. Detection of coronary calcium with electron beam tomography in coronary artery disease

    International Nuclear Information System (INIS)

    Haberl, R.; Knez, A.; Becker, A.; Becker, C.; Bruening, R.; Reiser, M.; Maass, A.; Steinbeck, G.

    1998-01-01

    Purpose: Coronary calcium is a powerful indicator of arteriosclerosis and can be detected very precisely with electron beam tomography. The method can be applied in patients with known coronary artery disease or in asymptomatic patients at risk of arteriosclerotic disease. Results: At the University of Munich we performed an EBT scan of the heart in 1100 patients within the last year. In 567 patients coronary angiography was performed also (±3 days). Confirming previous reports in the literature, we found a correlation of the calcium score with the age and gender of the patients. Severe coronary artery disease (stenoses ≥ 75%) was associated with significantly more calcium than less severe CAD. The calcium score did not discriminate between one-, two- and three-vessel disease. The site of calcification does not correlate with the localization of stenoses. Thirty-three percent of the patients with significant coronary artery disease showed a normal age-adjusted calcium score; a total of 8.1% of patients with severe stenoses did not reveal any coronary calcification (score =0). With asymptomatic patients there are only a few studies available. Soft plaques cannot be detected with EBT, but in most patients soft plaques occur together with hard plaques. Our results show that spiral CT of the newest generation may also be used for calcium screening. There was an excellent correlation of the calcium scores of EBT and spiral CT at all levels of calcification. Discussion: Coronary calcium is a sensitive marker of coronary artery disease. In the clinical setting EBT is indicated in patients with known coronary artery disease (to evaluate prognosis), in patients who are unable to perform a stress test, and in patients with atypical chest pain. However, lack of calcification may be associated with severe stenoses in a minority of patients. The clinical value in asymptomatic patients needs to be defined: Randomized studies are necessary. We see a possible indication in

  14. Detecting Periprocedural Myocardial Infarction in Contemporary Percutaneous Coronary Intervention Trials

    NARCIS (Netherlands)

    Spitzer, Ernest; de Vries, Ton; Cavalcante, Rafael; Tuinman, Marieke; Rademaker-Havinga, Tessa; Alkema, Maaike; Morel, Marie-Angele; Soliman, Osama I.; Onuma, Yoshinobu; van Es, Gerrit-Anne; Tijssen, Jan G. P.; McFadden, Eugene; Serruys, Patrick W.

    2017-01-01

    This study sought to investigate the differences in detecting (e.g., triggering) periprocedural myocardial infarction (PMI) among 3 current definitions. PMI is a frequent component of primary endpoints in coronary device trials. Identification of all potential suspected events is critical for

  15. [Usefullness of transesophageal echocardiography in early detection of coronary spasm].

    Science.gov (United States)

    Sagara, M; Haraguchi, M; Hamu, Y; Isowaki, S; Yoshimura, N

    1996-04-01

    Intraoperative transesophageal echocardiography (TEE) was performed on a 62-year-old man who underwent abdominal aortic replacement for abdominal aortic aneurysm under general anesthesia combined with epidural anesthesia. Coronary artery spasm occurred after unexpected massive hemorrhage, and TEE showed hypokinesis in the posterior-inferior left ventricular wall. The changes in TEE preceded the ST elevation in the ECG. Bolus infusion of isosorbide dinitrate and continuous infusion of nitroglycerin alleviated these changes. TEE enabled us to detect and evaluate coronary spasm before the appearance of ST changes in ECG.

  16. Sensor to detect endothelialization on an active coronary stent

    Directory of Open Access Journals (Sweden)

    Coffey Arthur C

    2010-11-01

    Full Text Available Abstract Background A serious complication with drug-eluting coronary stents is late thrombosis, caused by exposed stent struts not covered by endothelial cells in the healing process. Real-time detection of this healing process could guide physicians for more individualized anti-platelet therapy. Here we present work towards developing a sensor to detect this healing process. Sensors on several stent struts could give information about the heterogeneity of healing across the stent. Methods A piezoelectric microcantilever was insulated with parylene and demonstrated as an endothelialization detector for incorporation within an active coronary stent. After initial characterization, endothelial cells were plated onto the cantilever surface. After they attached to the surface, they caused an increase in mass, and thus a decrease in the resonant frequencies of the cantilever. This shift was then detected electrically with an LCR meter. The self-sensing, self-actuating cantilever does not require an external, optical detection system, thus allowing for implanted applications. Results A cell density of 1300 cells/mm2 on the cantilever surface is detected. Conclusions We have developed a self-actuating, self-sensing device for detecting the presence of endothelial cells on a surface. The device is biocompatible and functions reliably in ionic liquids, making it appropriate for implantable applications. This sensor can be placed along the struts of a coronary stent to detect when the struts have been covered with a layer of endothelial cells and are no longer available surfaces for clot formation. Anti-platelet therapy can be adjusted in real-time with respect to a patient's level of healing and hemorrhaging risks.

  17. Low QRS Voltage on Presenting Electrocardiogram Predicts Multi-vessel Disease in Anterior ST-segment Elevation Myocardial Infarction.

    Science.gov (United States)

    Kobayashi, Akihiro; Misumida, Naoki; Aoi, Shunsuke; Kanei, Yumiko

    Low QRS voltage was reported to predict adverse outcomes in acute myocardial infarction in the pre-thrombolytic era. However, the association between low voltage and angiographic findings has not been fully addressed. We performed a retrospective analysis of patients with anterior ST-segment elevation myocardial infarction (STEMI). Low QRS voltage was defined as either peak to peak QRS complex voltage voltage. Patients with low voltage had a higher rate of multi-vessel disease (MVD) (76% vs. 52%, p=0.01). Patients with low voltage were more likely to undergo coronary artery bypass grafting (CABG) during admission (11% vs. 2%, p=0.028). Low voltage was an independent predictor for MVD (OR 2.50; 95% CI 1.12 to 6.03; p=0.032). Low QRS voltage was associated with MVD and in-hospital CABG in anterior STEMI. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Detection of coronary artery calcification by ultrafast CT and correlation with angiography

    International Nuclear Information System (INIS)

    Zhang Shaoxiong; Dai Ruping; Lu Bin

    1997-01-01

    To investigate the relationship between coronary calcification and significant coronary stenosis ninety patients including 81 men and 9 women were studied asithage ranging from 27∼72 years (mean, 58 years). All patients had both ultrafast CT (UFCT) examination and coronary angiography within one month. Single slice mode with ECG gating and thickness of 3 mm were used in UFCT scan. Selected coronary angiography was performed by the Judkins technique. Among 160 vessels in which coronary calcifications were identified, 74% had significant coronary stenosis (>50% stenosis), and 77% of 154 vessels with significant coronary stenosis had calcification demonstrable by UFCT. In the younger age group the sensitivity of calcification for evaluating stenosis of coronary artery was lower and the specificity was generally higher than those in the elderly group. UFCT is a promising procedure for detecting coronary arterial disease, since this examination has high sensitivity and specificity, easy to conduct, noninvasive, and widely applicable for screening a large population

  19. Usefulness of detecting atherosclerosis by computed tomography. A relation to coronary artery stenosis

    International Nuclear Information System (INIS)

    Takasu, Junichiro; Yamamoto, Rie; Yokoyama, Kenichi

    1999-01-01

    Reports evaluating coronary artery calcification detection by nonenhanced computed tomography (CT) have verified the usefulness for diagnosis of coronary artery disease. In the condition of a mobile CT scanning at a public health examination, however, determination of coronary calcification remains unclear. We investigated, under this scanning condition, a relation between the characteristic of coronary artery calcification determined by conventional CT and coronary disease on arteriogram. The quantification of aortic wall thickening by enhanced CT was examined on the usefulness of detecting coronary artery disease. The CT density score and the characteristics of aortic atherosclerosis for 159 male patients 30 year-old or more (average age 60.7 years) were examined the relation to coronary artery stenoses. The CT density score was the strongest independent variable for determining the existence of coronary disease. The CT density cutoff score for detection of coronary disease was 50 equal to 50 HU the maximal CT density in the coronary arteries. The maximal aortic wall thickness was the strongest significant variable independent of the noted coronary risk factors for the severity of coronary stenosis on arteriogram. (author)

  20. Three-dimensional coronary MR angiography with continuous administration of Gd-DTPA. Delineation and detection of coronary artery stenosis

    International Nuclear Information System (INIS)

    Yokoyama, Kenichi

    1999-01-01

    Three-dimensional coronary MR angiography (3D coronary MRA) with Gd-DTPA administration was performed in 19 patients to evaluate the vascular delineation and diagnostic capability for stenotic lesions. A 3D fast low-angle shot (FLASH) with a navigator echo respiratory gating technique was used with a superconducting 1.5 tesla MR system (Vision, Siemens Medical Systems, Erlangen, Germany). Administration of the conventional T 1 contrast agent with extra-cellular distribution produced a significant increase in the SNR and CNR of the proximal coronary arterial images. Visual score of both the source images and the multiplanar reconstruction (MPR) images assessed by three radiologists was superior to those on control images (without contrast enhancement). The MRA findings of stenotic lesions of the coronary artery were compared with the results of the conventional coronary angiographic study. Overall sensitivity and specificity for the detection of stenosis were almost the same as those of control images. In conclusion, 3D coronary MRA with Gd-DTPA administration improved coronary artery delineation. However, further technical improvements are required to enhance the value of the technique in detecting stenoses. (author)

  1. Value of magnetic resonance imaging for the noninvasive detection of stenosis in coronary artery bypass grafts and recipient coronary arteries

    NARCIS (Netherlands)

    Langerak, Susan E.; Vliegen, Hubert W.; Jukema, J. Wouter; Kunz, Patrik; Zwinderman, Aeilko H.; Lamb, Hildo J.; van der Wall, Ernst E.; de Roos, Albert

    2003-01-01

    BACKGROUND: Magnetic resonance imaging (MRI) is a potential noninvasive diagnostic tool to detect coronary artery bypass graft stenosis, but its value in clinical practice remains to be established. We investigated the value of MRI in detecting stenotic grafts, including recipient vessels. METHODS

  2. Congenital Left Circumflex Coronary Artery Atresia Detected by 64-Slice Computed Tomography: A Case Report

    Directory of Open Access Journals (Sweden)

    Chen-Yuan Liu

    2007-06-01

    Full Text Available A variety of coronary artery disorders, including intramyocardial coronary segments and coronary artery anomalies, can result in sudden cardiac death, especially in young adults. The detection of structural coronary artery abnormalities is important in the management of patients at risk of sudden cardiac death. Coronary artery anomalies occur in about 1% of the population. Congenital absence of left circumflex coronary artery (LCX is a very rare vascular anomaly, and few cases have been reported in the literature, with a frequency of only 0.003% in all patients who underwent coronary angiography. Although coronary catheterization is the gold standard for the evaluation of coronary arterial patency disease, noninvasive computed tomography (CT is considered the diagnostic method of choice for the detection and evaluation of coronary artery anomaly. Herein, we report the case of a 17-year-old girl who presented with exertional dyspnea and chest pain and who was studied at our emergency department with the final diagnosis of LCX atresia detected by 64-slice CT. She may be the first case of congenital LCX atresia proved by multislice CT.

  3. Detecting culprit vessel of coronary artery disease with SPECT 99Tcm-MIBI myocardial imaging

    International Nuclear Information System (INIS)

    Luan Zhaosheng; Zhou Wen; Peng Yong; Su Yuwen; Tian Jianhe; Gai lue; Sun Zhijun

    2002-01-01

    Objective: To assess the value of detecting culprit vessel of coronary artery disease (CAD) with SPECT 99 Tc m -MIBI myocardial imaging. Methods: Forty-six patients with CAD were studied. Every patients had multiple-vessel lesion showed by coronary arteriography and was treated by revascularization as percutaneous transluminal angioplasty (PTCA), coronary artery bypass graft (CABG) or laser holing. Exercise (EX), rest (RE) and intravenous infusion of nitroglycerine (NTG) SPECT 99 Tc m -MIBI myocardial imagings were performed before revascularization. Exercise and rest images revealed the myocardial ischemia. NTG images revealed myocardial viability. Culprit vessels were detected according to the defects showed by above mentioned images. The veracity of detected culprit vessels was tested with the outcome of the reperfusion therapy. Results: In this group, the coronary arteriography revealed 107 lesioned coronary arteries. Myocardial imaging detected 46 culprit vessels including 23 left anterior descending (LAD), 19 left circumflex coronary artery (LCX) and 4 right coronary artery (RCA). All 46 culprit vessels underwent revascularization and had nice outcome. The veracity of 99 Tc m -MIBI myocardial imaging detected culprit vessels was high according to patients' outcome. Conclusion: Exercise, rest and NTG 99 Tc m -MIBI myocardial imaging is a great method for detecting culprit vessels in multivessel coronary disease

  4. Cardiac troponin T predicts occult coronary artery stenosis in patients with chronic kidney disease at the start of renal replacement therapy.

    Science.gov (United States)

    Hayashi, Terumasa; Obi, Yoshitsugu; Kimura, Tomonori; Iio, Ken-Ichiro; Sumitsuji, Satoru; Takeda, Yoshihiro; Nagai, Yoshiyuki; Imai, Enyu

    2008-09-01

    The high prevalence of asymptomatic coronary artery stenosis (CAS) in chronic kidney disease (CKD) has emerged as an important predictor of outcome. However, diagnostic tools that can identify asymptomatic CAS have not yet been established. We investigated whether asymptomatic patients at the initiation of renal replacement therapy (RRT) could be screened using cardiac troponin T (cTnT) and atherosclerotic surrogate markers such as ankle-brachial blood pressure index (ABPI) and intima-media thickness (IMT). Among 142 patients who were about to start RRT, 60 who were asymptomatic underwent coronary evaluation by multi-slice computed tomography (MSCT) and/or coronary angiography (CAG). CAG diagnosed 35 patients (43.8%) as CAS positive and 27 of them had multi-vessel disease. Factors associated with CAS were smoking, elevated cTnT, low ABPI and high IMT. Moreover, the severity of CAS was associated with smoking, cTnT and ABPI. Stepwise logistic regression analyses revealed that cTnT was a powerful predictor of asymptomatic multi-vessel CAS. Receiver operating characteristic analysis documented the usefulness of cTnT as a screening tool with a cut-off point 0.05 ng/ml. The optimal screening tool for multi-vessel CAS was cTnT (sensitivity, 92.6%; 95% CI, 82.7-99.9; specificity, 63.6%; 95% CI, 47.2-80.0). We concluded that cTnT should be measured as part of a strategy for detecting asymptomatic CAS, especially multi-vessel disease in patients with CKD at the start of RRT.

  5. Thallium 201 Exercise Scintigraphy for Detection of Multivessel Coronary Artery Disease After Transmural Myocardial Infarction

    Science.gov (United States)

    Ahmadpour, Hedayatolah; Siegel, Michael E.; Colletti, Patrick; Haywood, L. Julian

    1984-01-01

    Fifty patients with prior transmural myocardial infarction were studied with cardiac catheterization, coronary angiography, and thallium 201 exercise perfusion scintigraphy. Obstructive coronary disease involved two or three vessels in 37 patients. The sensitivity of a positive electrocardiographic test during exercise for detecting multivessel coronary disease was only 40 percent (15/37), and the sensitivity of a reversible defect on 201Tl perfusion scintigraphy was 48 percent (18/37). The combination of exercise testing and 201Tl scintigraphy detected multivessel coronary disease in 75 percent (28/37) (P < .05). New perfusion defects occurred in 61 percent (13/21) of patients with inferior myocardial infarction and multivessel coronary disease whereas it occurred in only 35 percent (5/14) of patients with prior anterior infarction and multivessel coronary disease (P < .05). 201Tl exercise perfusion scintigraphy appears to be more sensitive for detecting significant multivessel coronary disease in the presence of previous inferior infarction compared with previous anterior infarction. Combined graded exercise testing and 201Tl perfusion scintigraphy can reliably detect the presence of significant multivessel coronary disease after transmural myocardial infarction. ImagesFigure 3 PMID:6512876

  6. Myocardial scintigraphy using a fatty acid analogue detects coronary artery disease in hemodialysis patients.

    Science.gov (United States)

    Nishimura, Masato; Hashimoto, Tetsuya; Kobayashi, Hiroyuki; Fukuda, Toyofumi; Okino, Koji; Yamamoto, Noriyuki; Fujita, Hiroshi; Inoue Tsunehiko Nishimura, Naoto; Ono, Toshihiko

    2004-08-01

    Coronary artery disease contributes significantly to mortality in end-stage renal disease (ESRD) patients. Single-photon emission computed tomography (SPECT) using an iodinated fatty acid analogue, iodine-123-methyl iodophenylpentadecanoic acid (123I-BMIPP), can assess fatty acid metabolism in the myocardium. We investigated the ability of 123I-BMIPP SPECT to detect coronary artery disease in hemodialysis patients compared with 201thallium chloride (201Tl) SPECT. We prospectively studied 130 ESRD patients undergoing hemodialysis for a mean of 88.6 months (male/female, 77/53; mean age, 63.8 years). Dual SPECT using 123I-BMIPP and 201Tl was performed, followed by coronary angiography. SPECT findings were graded in 17 segments on a five-point scale (0, normal uptake; 4, none) and assessed as a summed score. By coronary angiography, 71.5% of patients (93/130) had significant coronary stenosis (> or =75%), and five patients showed coronary spasm without coronary stenosis. When a BMIPP summed score of 6 or more was defined as abnormal, sensitivity, specificity, and accuracy for detecting coronary artery disease by BMIPP SPECT were 98.0%, 65.6%, and 90.0%, respectively; in contrast, these parameters for detecting coronary artery disease by Tl SPECT were 84.7%, 46.9%, and 75.0%, respectively, when a Tl summed score of 1 or more was defined as abnormal. In receiver operating characteristic analysis, the area under the curve was 0.895 in BMIPP and 0.727 in Tl SPECT, respectively. Resting BMIPP SPECT is superior to Tl SPECT for detecting coronary lesions, and provides safe screening for coronary artery disease among maintenance hemodialysis patients.

  7. Toward the automatic detection of coronary artery calcification in non-contrast computed tomography data.

    Science.gov (United States)

    Brunner, Gerd; Chittajallu, Deepak R; Kurkure, Uday; Kakadiaris, Ioannis A

    2010-10-01

    Measurements related to coronary artery calcification (CAC) offer significant predictive value for coronary artery disease (CAD). In current medical practice CAC scoring is a labor-intensive task. The objective of this paper is the development and evaluation of a family of coronary artery region (CAR) models applied to the detection of CACs in coronary artery zones and sections. Thirty patients underwent non-contrast electron-beam computed tomography scanning. Coronary artery trajectory points as presented in the University of Houston heart-centered coordinate system were utilized to construct the CAR models which automatically detect coronary artery zones and sections. On a per-patient and per-zone basis the proposed CAR models detected CACs with a sensitivity, specificity and accuracy of 85.56 (± 15.80)%, 93.54 (± 1.98)%, and 85.27 (± 14.67)%, respectively while the corresponding values in the zones and segments based case were 77.94 (± 7.78)%, 96.57 (± 4.90)%, and 73.58 (± 8.96)%, respectively. The results of this study suggest that the family of CAR models provide an effective method to detect different regions of the coronaries. Further, the CAR classifiers are able to detect CACs with a mean sensitivity and specificity of 86.33 and 93.78%, respectively.

  8. Stress cine MRI for detection of coronary artery disease

    International Nuclear Information System (INIS)

    Sommer, T.; Hofer, U.; Schild, H.

    2002-01-01

    Stress testing is the cornerstone in the diagnosis of patients with suspected coronary artery disease (CAD). Stress echocardiography has become a well-established modality for the detection of ischemia-induced wall motion abnormalities. However, display and reliable interpretation of stress echocardiography studies are user-dependent, the test reproducibility is low, and 10 to 15% of patients yield suboptimal or non-diagnostic images. Due to its high spatial and contrast resolution, MRI is known to permit an accurate determination of left ventricular function and wall thickness at rest. Early stress MRI studies provided promising results with respect to the detection of CAD. However, the clinical impact was limited due to long imaging time and problematic patient monitoring in the MRI environment. Recent technical improvements - namely ultrafast MR image acquisition - led to a significant reduction of imaging time and improved patient safety. Stress can be induced by physical exercise or pharmacologically by administration of a beta 1 -agonist (dobutamine) or vasodilatator (dipyridamole and adenosine). The best developed and most promising stress MRI technique is a high-dose dobutamine/atropine stress protocol (10, 20, 30, 40 μg/kg/min; optionally 0.25-mg fractions of atropine up to maximal dose 1 mg). Severe complications (myocardial infarction, ventricular fibrillation and sustained tachycardia, cardiogenic shock) may be expected in 0.25% of patients. Currently, data of three high-dose dobutamine stress MRI studies are available, revealing a good sensitivity (83 - 87%) and specificity (83 - 86%) in the assessment of CAD. The direct comparison between echocardiography and MRI for the detection of stress-induced wall motion abnormalities yielded better results for dobutamine-MRI in terms of sensitivity (86.2% vs. 74.3%; p [de

  9. Videodensitometric quantitative angiography after coronary balloon angioplasty, compared to edge-detection quantitative angiography and intracoronary ultrasound imaging

    NARCIS (Netherlands)

    Peters, R. J.; Kok, W. E.; Pasterkamp, G.; von Birgelen, C.; Prins, M. [=Martin H.; Serruys, P. W.

    2000-01-01

    AIMS: To assess the value of videodensitometric quantification of the coronary lumen after angioplasty by comparison to two other techniques of coronary artery lumen quantification. METHODS AND RESULTS: Videodensitometric quantitative angiography, edge detection quantitative angiography and 30 MHz

  10. Exercise, stress or what. The non-invasive detection of latent coronary artery disease

    International Nuclear Information System (INIS)

    Coltart, J.; Robinson, P.S.

    1978-01-01

    This communication discusses the methods of detecting latent coronary artery disease in an entirely asymptomatic individual with no previous symptoms or signs suggestive of coronary artery disease. Isotope techniques are being increasingly employed in the detection and assessment of coronary artery disease in that they may enable the confirmation of the presence of ischaemia, the extent and location of the underlying coronary artery disease and the effect of ischaemia on overall and regional left ventricular function. Three groups of techniques are commonly employed: 1. assessment of myocardial perfusion; 2. labelling of acute myocardial infarction; 3. overall and regional left ventricular function studies. Isotopes of potassium were initially studied, and, despite technical problems with imaging, 43 K has proved a useful agent in that over a range of coronary flow rates from normal to severely reduced flow, myocardial uptake parallels myocardial blood flow. Myocardial perfusion imaging should enhance the sensitivity and specificity of exercise testing in the symptomatic population and should also be helpful in the asymptomatic population although data on such populations are as yet extremely limited. Acute infarct labelling has little relevance to the very early detection of coronary artery disease. Assessment of overall and regional left ventricular function using gated blood pool scanning at rest and possibly also during exercise has potentially very wide applications in ischaemic heart disease and in combination with myocardial perfusion scanning in the assessment of symptomatic ischaemic heart disease and the detection of ischaemia and coronary artery disease in the asymptomatic population. (Auth.)

  11. The value and limitation thallium scintigraphy in the detection of coronary artery disease

    International Nuclear Information System (INIS)

    Khan, A.; Rehman, A.; Amin, W.; Khan, Z.A.; Ahmed, S.A.

    1986-01-01

    In this study we randomly selected 45 patients whose coronary angiograms were abnormal i.e. showing triple, double and single vessel disease out of a pool of 80 patients who had undergone stress thallium imaging and coronary angiography during the one year. Majority of these patients were males, their ages ranged between 34-54 years. Resting ECG's were normal in 25 patients, 15 patients had suffered inferior myocardial infraction and 5 had sustained anterior myocardial infraction in the past. Coronary angiography revealed triple vessel disease in 20 patients, double vessel disease in 15, and single vessel coronary artery disease in 10. We analysed their coronary angiograms and compared them with the scintigraphic finding. It is concluded that although thallium scanning has high sensitivity for detection of coronary artery disease in general, it has only moderate sensitivity for detection of stenosis in individual coronary arteries. In this study thallium scan identified 75% of RCA lesions, 66% of LAD lesions and 38% of circumflex lesions. The sensitivity is much higher in single vessel coronary artery disease. (author)

  12. Coronary artery calcification detected by a mobile helical CT unit in a mass screening. The frequency and relationship to coronary risk factors and coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Itani, Yasutaka; Watanabe, Shigeru; Masuda, Yoshiaki [Chiba Univ. (Japan). School of Medicine; Hanamura, Kazuhisa; Asakura, Kazuhiro; Sone, Shusuke; Sunami, Yuko; Shimura, Akimitsu; Miyamoto, Tadaaki

    2001-06-01

    A strong relationship is known to exist between coronary artery disease (CAD) and coronary artery calcification (CAC) detected by CT. In this study, we investigated the frequency of CAC and the relationship between coronary risk factors, CAD and CAC in a mass screening using a mobile helical CT unit. The total number of participants was 10008 people undergoing a medical examination for lung cancer and tuberculosis using a mobile helical CT unit. We measured the CT density of the coronary artery to detect CAC. The CT density threshold for determining CAC was above +110HU. The frequency of CAC was 16.0% in the overall patient population and significantly higher in males than in females (20.6% vs 10.7%). Frequency increased with age in both genders. Hypertension and diabetes mellitus were significantly related to CAC. Smoking showed a correlation with CAC only in males. A significant relationship was observed between CAD and CAC in males. In particular, the relationship between them was strongest in males under 60 years of age. Furthermore, the odds ratio of CAC in predicting CAD increased with increasing risk factors in both genders. (author)

  13. Diagnostic advantages of the association of electrocardiograms and thallium 201 exercise scintigraphy in detecting coronary disease

    International Nuclear Information System (INIS)

    Tubau, J.F.; Chaitman, B.R.; Dupras, G.; Waters, D.D.; Bourassa, M.G.

    1979-01-01

    Thallium 201 exercise scintigraphy combined with 14-lead exercise electrocardiography detects coronary artery disease in 95-96 percent of the patients, whether men or women. When both tests were positive, 93 percent of the men and 100 percent of the women had coronary artery disease. In women, thallium 201 seems to do better than 14-lead exercise electrocardiogram, detecting the presence of coronary artery disease in 72 percent and its absence in 83 percent of the cases. In approximately 50 percent of the cases, the results of thallium 201 and multiple-lead exercise testing were discordant; in these cases, an accurate clinical history is helpful. (author) [fr

  14. Detection of coronary artery disease by exercise radionuclide ventriculography, (1)

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Saito, Muneyasu; Uehara, Toshiisa; Kozuka, Takahiro

    1982-01-01

    In order to assess the detection of coronary artery disease (CAD) and LV functional reserve, exercise radionuclide ventriculography (ERV) were performed in 80 patients who underwent selective cardiac catneterization for evaluation of chest pain syndrome. 70 patients had CAD (30 patients with angina pectoris and 40 patients with myocardial infarction) and 10 did not. In this study, to obtain accurate data by ERV, its practical consideration were metioned. Radionuclide cardioangiography with sup(99m)Tc-invivo RBC labelling were performed using an Anger camera attached with high-sense collimator and on-line minicomputer system. For data aquisition, multi-gated method were used, especially during exercise, list mode collection was suitable for ERV because of variable R-R intervals. Patient stability was performed with an adjustable shoulder support and hand grip, ECG monitoring system by carbon electrolode was used to obtain during exercise. Exercise protocal was graded bicycle ergometer in supine position. As the results, in the patients of CAD, changes of LVEF from rest to exercise were under 5%, while in normal patients, LVEF increased over 5% in all patients. In 30 patients with angina pectoris, the ERV was abnormal in 25 for a sensitivity of 83.3% and specificity of 100%. The ERV were thought to be superior than stress ECG for the detection of CAD. In conclusion, with increasing clinical application, the use of ERV is rapidly becoming wider-spread but the excellent results were thought to depend upon the careful attention to equipment and exercise procedure. (author)

  15. Exercise radionuclide ventriculography to detect restenosis following coronary angioplasty

    International Nuclear Information System (INIS)

    De Puey, E.G.; Leatherman, L.L.; Dear, W.E.; Leachman, R.D.; Massin, E.K.; Mathur, V.S.; Burdine, J.A.

    1984-01-01

    Forty one patients (pts) underwent semiupright exercise gated radionuclide ventriculography (EGRNV) before, within 3 d after single vessel transluminal coronary angioplasty (TCA), and 4 to 12 mos later, at which time follow-up cardiac catheterization was also performed. Prior to TCA 76% of pts had abnormal EGRNV, as defined by a failure to increase ejection fraction (EF) by 5 points or the development of a new regional wall motion abnormality. Stenosis was reduced from 90 +- 7% to 18 +- 17%. Early after TCA, exercise duration and maximum double product increased (p's 20% but <50%; Group III (n=8): ≥ 50%] Pts with abnormal EGRNV early after TCA were demonstrated to have a greater percent increase in stenosis at late follow-up than pts with normal EGRNV (41 +- 30% vs 19 +- 25%, p<.001). Early after TCA EGRNV was abnormal in 5% of Group I pts vs 75% in Group III (p<.01), and EF increased to a greater degree during exercise in Group I pts (+11.3 +- 7.5 vs +3.5 +- 6.5 points, p<.01). At 4-12 mos EGRNV was abnormal in 27% of Group I vs 88% of Group III (p<.01), and during exercise EF increased in Group I pts (+11.8 +- 7.8 points) but decreased in Group III (-1.9 +- 8.7 points) (p<.0005). The accuracy of abnormal EGRNV in predicting ≥ 50% restenosis was 73% early post-TCA and 77% at 4-12 mos. The authors conclude that EGRNV is a valuable test to verify the success of TCA and to detect subsequent restenosis

  16. Three dimensional quantitative coronary angiography can detect reliably ischemic coronary lesions based on fractional flow reserve.

    Science.gov (United States)

    Chung, Woo-Young; Choi, Byoung-Joo; Lim, Seong-Hoon; Matsuo, Yoshiki; Lennon, Ryan J; Gulati, Rajiv; Sandhu, Gurpreet S; Holmes, David R; Rihal, Charanjit S; Lerman, Amir

    2015-06-01

    Conventional coronary angiography (CAG) has limitations in evaluating lesions producing ischemia. Three dimensional quantitative coronary angiography (3D-QCA) shows reconstructed images of CAG using computer based algorithm, the Cardio-op B system (Paieon Medical, Rosh Ha'ayin, Israel). The aim of this study was to evaluate whether 3D-QCA can reliably predict ischemia assessed by myocardial fractional flow reserve (FFR) < 0.80. 3D-QCA images were reconstructed from CAG which also were evaluated with FFR to assess ischemia. Minimal luminal diameter (MLD), percent diameter stenosis (%DS), minimal luminal area (MLA), and percent area stenosis (%AS) were obtained. The results of 3D-QCA and FFR were compared. A total of 266 patients was enrolled for the present study. FFR for all lesions ranged from 0.57 to 1.00 (0.85 ± 0.09). Measurement of MLD, %DS, MLA, and %AS all were significantly correlated with FFR (r = 0.569, 0609, 0.569, 0.670, respectively, all P < 0.001). In lesions with MLA < 4.0 mm(2), %AS of more than 65.5% had a 80% sensitivity and a 83% specificity to predict FFR < 0.80 (area under curve, AUC was 0.878). 3D-QCA can reliably predict coronary lesions producing ischemia and may be used to guide therapeutic approach for coronary artery disease.

  17. 16S rRNA-based detection of oral pathogens in coronary atherosclerotic plaque

    Directory of Open Access Journals (Sweden)

    Mahendra Jaideep

    2010-01-01

    Full Text Available Background: Atherosclerosis develops as a response of the vessel wall to injury. Chronic bacterial infections have been associated with an increased risk for atherosclerosis and coronary artery disease. The ability of oral pathogens to colonize in coronary atheromatous plaque is well known. Aim: The aim of this study was to detect the presence of Treponema denticola, Porphyromonas gingivalis and Campylobacter rectus in the subgingival and atherosclerotic plaques of patients with coronary artery disease. Materials and Methods: Fifty-one patients in the age group of 40-80 years with coronary artery disease were selected for the study. DNA was extracted from the plaque samples. The specific primers for T. denticola, C. rectus and P. gingivalis were used to amplify a part of the 16S rRNA gene by polymerase chain reaction. Statistical Analysis Used: Chi-square analysis, correlation coefficient and prevalence percentage of the microorganisms were carried out for the analysis. Results: Of the 51 patients, T. denticola, C. rectus and P. gingivalis were detected in 49.01%, 21.51% and 45.10% of the atherosclerotic plaque samples. Conclusions: Our study revealed the presence of bacterial DNA of the oral pathogenic microorganisms in coronary atherosclerotic plaques. The presence of the bacterial DNA in the coronary atherosclerotic plaques in significant proportion may suggest the possible relationship between periodontal bacterial infection and genesis of coronary atherosclerosis.

  18. Sensitivity of thallium scintigraphy in the detection of individual coronary artery disease

    International Nuclear Information System (INIS)

    Khan, A.; Rehman, A.; Wiqar, M.A.; Khan, Z.A.; Ahmad, S.A.

    1988-01-01

    In this study we randomly selected 45 patients whose coronary angiograms were abnormals i.e. showing triple, double and single vessel disease. Out of 80 patients who had undergone stress thallium imaging and coronary angiography during the one year. Majority of these patients were males and their ages ranged between 34-54 years. Fifteen patients had suffered inferior myocardial infraction and 5 had sustained anterior myocardial infraction in the fast. We analysed their coronary angiograms and compared them with the scintigraphic findings. It is concluded that although thallium scanning has high sensitivity for detection of coronary artery disease in general, it has only moderate sensitivity for detection of stenosis in individual coronary arteries. In this study thallium scan identified 75% of RCA lesions, 66% of LAD lesions and 38% circumflex lesions. Thallium scan sometimes fails to identify the less serve lesions in presence of more severe coronary lesions in the some patients. The sensitivity is much higher in single vessel coronary artery disease. (author)

  19. Significance of coronary artery calcification detected incidentally with chest CT

    International Nuclear Information System (INIS)

    Moore, E.H.; Greenberg, R.; Miller, S.W.; Shepard, J.O.; Bourgouin, P.M.; McLoud, T.C.

    1987-01-01

    Coronary artery calcifications are well seen on CT scans because of high contrast resolution. Individual vessels were scored 0-3+ based on degree of calcification in over 40 patients who also underwent cardiac catheterization. Though relatively insensitive, the presence of dense calcifications had a specificity of roughly 60% to 70% for the presence of severe stenosis. In addition, 30 patients with calcification on CT scans and 30 age-matched controls, all of whom underwent thoracotomy, were compared with respect to prior cardiac history, estimated anesthetic risk, and postoperative cardiac complications. Patients with calcifications were more likely to have evidence of coronary disease and/or encounter postoperative cardiac complications

  20. Myocardial perfusion SPECT in diabetic patients for detection of coronary artery disease

    International Nuclear Information System (INIS)

    Saeed, M.A.; Fatima, S.; Fatmi, S.; Kureshi, S.

    2003-01-01

    The aim of this study was to evaluate the efficacy of myocardial SPECT perfusion scan in the diagnosis of coronary artery disease in diabetic patients. A total number of thirty diabetic patients (21 males, 9 females) were included in the study. All the patients had strong risk-factors for coronary artery disease (strong family history, chronic smokers, hyperlipidemia, history of chest pain). All patients underwent coronary angiography and stress/rest myocardial perfusion SPECT scans with Tc-99m MIBI (two days protocol). Twenty two patients had significant coronary artery stenosis and 8 had normal coronary arteries. Myocardial perfusion scintigraphy (MPS) was positive in 19 subjects out of the 22 patients with significant stenosis (Sensitivity 86.4%) and negative (false negative) in only three. Out of 8 patients with normal angiography 7 had normal MPS (Specificity 87.5%) whereas only one patient revealed abnormality in the myocardial perfusion study. When compared with coronary angiography the positive predictive value and negative predictive value for Tc-99m MIBI myocardial perfusion scan was 86.4% and 87.5% respectively. In conclusion, Tc-99m MIBI myocardial perfusion scintigraphy is a useful screening modality for the detection of coronary artery disease in diabetic patients. (author)

  1. Target vessel detection by epicardial ultrasound in off-pump coronary bypass surgery.

    Science.gov (United States)

    Hayakawa, Masato; Asai, Tohru; Kinoshita, Takeshi; Suzuki, Tomoaki; Shiraishi, Shoichiro

    2013-01-01

    The detection of embedded coronary arteries is difficult especially in off-pump coronary bypass surgery. From June 2010, we introduced high-frequency epicardial ultrasound (ECUS) to assess and evaluate embedded arteries during off-pump coronary bypass surgery. Between June 2010 and June 2011, a total of 89 consecutive patients underwent isolated coronary bypass surgery at our institution. The patients consisted of 72 men and 17 women with a mean age of 67.9 years. We routinely use the VeriQC system (MediStim, Oslo, Norway) to detect the target vessels in the operation. The patients were assigned to one of two groups, depending on whether ECUS was used in the operation (n = 10, ECUS group) or not (n = 79, non-ECUS group). We analyzed the impact of introducing the ECUS in terms of operative outcome. All patients underwent revascularization using the off-pump technique without emergent conversion to cardiopulmonary bypass during surgery. The total number of distal anastomoses was 299, and 12 target vessels could not be identified either visually or on palpation. Thus, the frequency of the embedded coronary arteries was 4.01% (12/299 cases). The preoperative profiles of the two groups were not significantly different. Operation time was significantly longer in the ECUS group (P = 0.02). There were no significant differences in postoperative outcome between the two groups. In the present study, in which the target coronary arteries could not be detected either visually or on palpation in 12 (4.01%) of 299 cases, the use of high-frequency ECUS allowed all patients to undergo off-pump coronary bypass surgery without conversion to cardiopulmonary bypass during the operation. High-frequency ECUS is therefore useful in off-pump coronary bypass surgery.

  2. Regadenoson in the detection of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Christiane Buhr

    2008-04-01

    Full Text Available Christiane Buhr1, Mario Gössl2, Raimund Erbel1, Holger Eggebrecht11Department of Cardiology, West-German Heart Center Essen, University of Duisburg-Essen, Essen, Germany; 2Cardiovascular Diseases, Mayo Clinic College of Medicine, Rochester, MN 55905, USAAbstract: Myocardial perfusion studies use either physical exercise or pharmacologic vasodilator stress to induce maximum myocardial hyperemia. Adenosine and dipyridamole are the most commonly used agents to induce coronary arterial vasodilation for myocardial perfusion imaging. Both cause frequent undesirable side-effects. Because of its ultrashort half-life, adenosine must be administered by constant intravenous infusion during the examination. A key feature of an ideal A2A agonist for myocardial perfusion imaging studies would be an optimal level and duration of hyperemic response. Drugs with a longer half-time and more selective A2A adenosine receptor agonism, such as regadenoson, should theoretically result in a similar degree of coronary vasodilation with fewer or less severe side-effects than non-selective, ultrashort-lasting adenosine receptor stimulation. The available preclinical and clinical data suggest that regadenoson is a highly subtype-selective, potent, low-affinity A2A adenosine receptor agonist that holds promise for future use as a coronary vasodilator in myocardial perfusion imaging studies. Infusion of regadenoson achieves maximum coronary hyperemia that is equivalent to adenosine. After a single bolus infusion over 10 s, hyperemia is maintained significantly longer (approximately 2–5 min than with adenosine, which should facilitate radionuclide distribution for myocardial perfusion imaging studies. In comparison with the clinically competitive A2A adenosine receptor agonist binodenoson, regadenoson has a several-fold shorter duration of action, although the magnitude of hyperemic response is comparable between the two. The more rapid termination of action of regadenoson

  3. The Olson method for detection of acute myocardial ischemia in patients with coronary occlusion.

    Science.gov (United States)

    Lindow, Thomas; Olson, Charles W; Swenne, Cees A; Man, Sumche; Pahlm, Olle

    An automated ECG-based method may provide diagnostic support in the management of patients with acute coronary syndrome. The Olson method has previously proved to accurately identify the culprit artery in patients with acute coronary occlusion. The Olson method was applied to 360 patients without acute myocardial ischemia and 52 patients with acute coronary occlusion. This study establishes the normal variation of the Olson wall scores in patients without acute myocardial ischemia, which provides the basis for implementation of the Olson method for triage of patients with acute coronary syndrome. All patients with acute occlusion had Olson wall scores above the upper limit of normal. The Olson method can be used for ischemia detection with very high sensitivity. Future studies are needed to explore specificity in patients with non-ischemic ST elevation. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Isoproterenol stress thallium scintigraphy for detecting coronary artery disease

    International Nuclear Information System (INIS)

    Watanabe, Shigeyuki; Ajisaka, Ryuichi; Masuoka, Takeshi; Iida, Kaname; Sugishita, Yasuro; Ito, Iwao; Takeda, Tohru; Toyama, Hinako; Akisada, Masayoshi

    1989-01-01

    The present study was undertaken to assess the diagnostic value of isoproterenol (ISP) thallium scintigraphy. The findings were compared with those of ISP-ECG and exercise thallium scintigraphy. The study population consisted of 24 patients who had a history of chest pain without previous myocardial infarction. ISP was given at increasing doses of 0.02, 0.04, 0.08 μg/mg/min at 3-minutes intervals, and was terminated for any of the following reasons: angina, significant arrhythmia, significant ST segment depression, or target heart rate. Thallium scintigrams were obtained immediately after terminating ISP infusion, and after a 3-hour delay, redistribution scans were obtained. Scintigrams were considered positive when a reversible defect was present. After stress tests, coronary angiography was performed. According to the presence or absence of significant coronary artery stenosis, the patients were divided into coronary artery disease (CAD) group (n=12) and so-called normal coronary (NC) group (n=12). Among 12 patients in the CAD group, ISP induced anginal pain in six (50%), and ISP-ECT and ISP thallium scintigraphy were positive in 10 (83%) and in 11 (92%), compared with four(33%), four(33%) and two (17%) in the NC group. These data indicate that ISP-ECG had a sensitivity of 83%, a specificity of 67%, and a diagnostic accuracy of 75%; and the corresponding figures for ISP thallium scintigraphy were 92%, 83%, and 88%. Among nine patients who underwent both ISP thallium scintgraphy and exercise thallium scintigraphy, all patients, except for one false negative case on ISP thallium scintigraphy, were correctly diagnosed. No serious complications occurred in association with the ISP infusion test. ISP thallium scintigraphy was considered to be a safe, sensitive, and specific method for diagnosing CAD when exercise tests were intolerable. (N.K.)

  5. T1-weighted MRI for the detection of coronary artery plaque haemorrhage

    International Nuclear Information System (INIS)

    Oei, May Lin; Ozgun, Murat; Seifarth, Harald; Bunck, Alexander; Fischbach, Roman; Heindel, Walter; Maintz, David; Orwat, Stefan; Botnar, Rene

    2010-01-01

    Hyperintense areas in atherosclerotic plaques on pre-contrast T1-weighted MRI have been shown to correlate with intraplaque haemorrhage. We evaluated the presence of T1 hyperintensity in coronary artery plaques in coronary artery disease (CAD) patients and correlated results with multi-detector computed tomography (MDCT) findings. Fifteen patients with CAD were included. Plaques detected by MDCT were categorised based on their Hounsfield number. T1-weighted inversion recovery (IR) MRI prepared coronary MRI for the detection of plaque and steady-state free-precession coronary MR-angiography for anatomical correlation was performed. After registration of MDCT and MRI, regions of interest were defined on MDCT-visible plaques and in corresponding vessel segments acquired with MRI. MDCT density and MR signal measurement were performed in each plaque. Forty-three plaques were identified with MDCT. With IR-MRI 5/43 (12%) plaques were hyperintense, 2 of which were non-calcified and 3 mixed. Average signal-to-noise and contrast-to-noise ratios of hyperintense plaques were 15.7 and 9.1, compared with 5.6 and 1.2 for hypointense plaques. Hyperintense plaques exhibited a significantly lower CT density than hypointense plaques (63.6 vs. 140.8). There was no correlation of plaque signal intensity with degree of stenosis. T1-weighted IR-MRI may be useful for non-invasive detection and characterisation of intraplaque haemorrhage in coronary artery plaques. (orig.)

  6. Multislice CT coronary angiography: evaluation of an automatic vessel detection tool

    International Nuclear Information System (INIS)

    Dewey, M.; Schnapauff, D.; Lembcke, A.; Hamm, B.; Rogalla, P.; Laule, M.; Borges, A.C.; Rutsch, W.

    2004-01-01

    Purpose: To investigate the potential of a new detection tool for multisliceCT (MSCT) coronary angiography with automatic display of curved multiplanar reformations and orthogonal cross-sections. Materials and Methods: Thirty-five patients were consecutively enrolled in a prospective intention-to-diagnose study and examined using a MSCT scanner with 16 x 0.5 mm detector collimation and 400 ms gantry rotation time (Aquilion, Toshiba). A multisegment algorithm using up to four segments was applied for ECG-gated reconstruction. Automatic and manual detection of coronary arteries was conducted using the coronary artery CT protocol of a workstation (Vitrea 2, Version 3.3, Vital Images) to detect significant stenoses (≥50%) in all segments of ≥1.5 mm in diameter. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of conventional coronary angiography. Results: The overall sensitivity, specificity, nondiagnostic rate, and accuracy of the automatic and manual approach were 90 vs. 94%, 89 vs. 84%, 6 vs. 6%, and 89 vs. 88%, respectively (p=n.s.). The vessel length detected with the automatic and manual approach were highly correlated for the left main/left anterior descending (143±30 vs. 146±24 mm, r=0.923, p [de

  7. Noninvasive detection of coronary thrombi with 111In platelets: concise communication

    International Nuclear Information System (INIS)

    Bergmann, S.R.; Lerch, R.A.; Mathias, C.J.; Sobel, B.E.; Welch, M.J.

    1983-01-01

    The need for rapid, definitive identification of coronary thrombosis has been intensified by the advent of thrombolytic therapy and by interest in the role of thrombosis in the etiology of coronary artery disease. To determine whether platelet thrombi can be detected noninvasively with 111 In platelets, a method was developed in which /sup 99m/Tc-tagged red blood cells were used to correct for activity within the blood attributable to platelets circulating but not associated with thrombus. In 18 dogs coronary thrombi were induced closed-chest with a copper coil introduced into the coronary artery. 111 In platelets and /sup 99m/Tc RBCs were administered either before or 1 hr after induction of thrombus, and serial scintigrams obtained. Coronary thrombus was identified readily in the processed scintigrams. In six dogs, thrombolysis was achieved with intracoronary streptokinase. In each case serial scintigraphy demonstrated resolution of the clot. The dual radiotracer technique should permit serial noninvasive delineation of the temporal relationship between platelet deposition and coronary heart disease in patients, and should facilitate the evaluation of interventions designed to prevent platelet aggregation or to lyse existing thrombi

  8. Thallium-201 myocardial imaging in the detection of coronary artery disease

    International Nuclear Information System (INIS)

    McKillop, J.H.; Murray, R.G.; Turner, J.G.; Gray, H.W.; Bessent, R.G.; Lorimer, A.R.; Greig, W.R.

    1978-01-01

    Thallium-201 myocardial imaging can detect abnormalities of myocardial perfusion. Visual interpretation of the images is complicated by some inhomogeneity of tracer uptake normally present. Using a quantitative approach we have established the regional variation of Thallium-201 uptake present in 23 normal controls and applied the same technique to 49 patients who had undergone selective coronary arteriography with left ventriculography because of chest pain. Half of the patients with significant coronary artery disease had abnormal rest Thallium-201 images, usually corresponding to areas of abnormal wall motion at ventriculography. Stress Thallium-201 images were abnormal in over 90% of patients with coronary artery disease. The stress image abnormalities and the arteriographic lesions correlated well in most patients with single and double vessel disease but in triple vessel disease the correspondence between the two studies was poor. Two of a group of patients with normal coronary arteriograms had abnormal Thallium-201 images due to other myocardial pathology. Our technique was highly sensitive in the non-invasive detection of significant coronary artery disease in a group of patients with chest pain. A small number of positive studies were also encountered due to other myocardial disorders. (author)

  9. Characteristics of coronary artery disease in symptomatic type 2 diabetic patients: evaluation with CT angiography

    Directory of Open Access Journals (Sweden)

    Zhu Zhi-yu

    2010-11-01

    Full Text Available Abstract Background Coronary artery disease (CAD is a common and severe complication of type 2 diabetes mellitus (DM. The aim of this study is to identify the features of CAD in diabetic patients using coronary CT angiography (CTA. Methods From 1 July 2009 to 20 March 2010, 113 consecutive patients (70 men, 43 women; mean age, 68 ± 10 years with type 2 DM were found to have coronary plaques on coronary CTA. Their CTA data were reviewed, and extent, distribution and types of plaques and luminal narrowing were evaluated and compared between different sexes. Results In total, 287 coronary vessels (2.5 ± 1.1 per patient and 470 segments (4.2 ± 2.8 per patient were found to have plaques, respectively. Multi-vessel disease was more common than single vessel disease (p p p p p = 0.855. Extent of CAD, types of plaques and luminal narrowing were not significantly different between male and female diabetic patients. Conclusions Coronary CTA depicted a high plaque burden in patients with type 2 DM. Plaques, which were mainly calcified, were more frequently detected in the proximal segment of the LAD artery, and increased attention should be paid to the significant prevalence of obstructive stenosis. In addition, DM reduced the sex differential in CT findings of CAD.

  10. Peripheral arterial tonometry cannot detect patients at low risk of coronary artery disease

    NARCIS (Netherlands)

    M.M. van den Heuvel (Mieke); O. Sorop (Oana); P. Musters (Paul); R.T. van Domburg (Ron); T.W. Galema (Tjebbe); D.J.G.M. Duncker (Dirk); W.J. van der Giessen (Wim); K. Nieman (Koen)

    2015-01-01

    textabstractBackground Endothelial dysfunction precedes coronary artery disease (CAD) and can be measured by peripheral arterial tonometry (PAT). We examined the applicability of PAT to detect a low risk of CAD in a chest pain clinic. Methods In 93 patients, PAT was performed resulting in reactive

  11. Comparison of multi-slice CT (MSCT) and TI-201 myocardial SPECT in detection of coronary artery disease: relation to coronary arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Pai, M. S.; Kim, Y. K.; Shim, S. S. [College of Medicine, Univ. of Ewha Womens, Seoul (Korea, Republic of)

    2003-07-01

    To evaluate the diagnostic potentials of MSCT and TI-201 SPECT in the assessment of coronary artery disease. Twenty-four patients (15 men, 9 women, 42-79 years) with clinically suspected coronary artery disease were studied by TI-201 myocardial SPECT and MSCT. MSCT data were obtained with 12 x 0.75 mm, 420ms rotation, multi-slice CT scanner (SOMATOM Sensation, Siemens) using non-ionic contrast, 80ml, 4ml/sec. Multiplanar reconstruction techniques were used for evaluation of coronary arteries. TI-201 myocardial SPECT were performed at stress with adenosine and at rest. Data from MSCT and TI-201 SPECT were compared territory by territory (divided into two segments; LAD and RCA/LCx) and related to coronary arteriography, in which more than 60% stenoses are regarded as significant. MSCT and TI-201 SPECT showed agreement in 37 out of 48 segments (77.1%). Out of 11 disagreed segments (22.9), TI-201 SPECT was superior in 6 segments and MSCT was superior in 5 segments. Sensitivities and specificities of MSCT and TI-201 SPECT by coronary arteriography are 81.8%, 69.2% and 86.3%, 76.9%, respectively. Agreed 4 segments between MSCT and TI-201 SPECT exhibited results that differ from the results of coronary arteriography. Myocardial bridge in two cases were detected as significant stenoses by MSCT but showed normal perfusion in TI-201 SPECT. Agreement between MSCT and TI-201 SPECT in the assessment of coronary artery disease was good but TI-201 SPECT has higher sensitivity and specificity for the detection of jeopardized myocardium than MSCT. MSCT and TI-201 SPECT provide complementary information in the assessment of coronary artery disease and could help reduce probable mistake in the interpretation of hemo dynamically insignificant lesion in coronary arteriography.

  12. A systematic review on diagnostic accuracy of CT-based detection of significant coronary artery disease

    International Nuclear Information System (INIS)

    Janne d'Othee, Bertrand; Siebert, Uwe; Cury, Ricardo; Jadvar, Hossein; Dunn, Edward J.; Hoffmann, Udo

    2008-01-01

    Objectives: Systematic review of diagnostic accuracy of contrast enhanced coronary computed tomography (CE-CCT). Background: Noninvasive detection of coronary artery stenosis (CAS) by CE-CCT as an alternative to catheter-based coronary angiography (CCA) may improve patient management. Methods: Forty-one articles published between 1997 and 2006 were included that evaluated native coronary arteries for significant stenosis and used CE-CCT as diagnostic test and CCA as reference standard. Study group characteristics, study methodology and diagnostic outcomes were extracted. Pooled summary sensitivity and specificity of CE-CCT were calculated using a random effects model (1) for all coronary segments, (2) assessable segments, and (3) per patient. Results: The 41 studies totaled 2515 patients (75% males; mean age: 59 years, CAS prevalence: 59%). Analysis of all coronary segments yielded a sensitivity of 95% (80%, 89%, 86%, 98% for electron beam CT, 4/8-slice, 16-slice and 64-slice MDCT, respectively) for a specificity of 85% (77%, 84%, 95%, 91%). Analysis limited to segments deemed assessable by CT showed sensitivity of 96% (86%, 85%, 98%, 97%) for a specificity of 95% (90%, 96%, 96%, 96%). Per patient, sensitivity was 99% (90%, 97%, 99%, 98%) and specificity was 76% (59%, 81%, 83%, 92%). Heterogeneity was quantitatively important but not explainable by patient group characteristics or study methodology. Conclusions: Current diagnostic accuracy of CE-CCT is high. Advances in CT technology have resulted in increases in diagnostic accuracy and proportion of assessable coronary segments. However, per patient, accuracy may be lower and CT may have more limited clinical utility in populations at high risk for CAD

  13. Arm exercise-thallium imaging testing for the detection of coronary artery disease

    International Nuclear Information System (INIS)

    Balady, G.J.; Weiner, D.A.; Rothendler, J.A.; Ryan, T.J.

    1987-01-01

    Patients with lower limb impairment are often unable to undergo a standard bicycle or treadmill test for the evaluation of coronary artery disease. To establish an alternative method of testing, 50 subjects (aged 56 +/- 10 years) performed arm ergometry testing in conjunction with myocardial thallium scintigraphy. All underwent coronary angiography; significant coronary artery disease (greater than or equal to 70% stenosis) in at least one vessel was present in 41 (82%) of the 50 patients. Thallium scintigraphy was found to have an 83% sensitivity and 78% specificity for detecting coronary disease, compared with a sensitivity and specificity of 54% (p less than 0.01) and 67% (p = NS), respectively, for exercise electrocardiography. In the subgroup of 23 patients who had no prior myocardial infarction or left bundle branch block and were not taking digitalis, thallium scintigraphy had a sensitivity of 80% versus 50% for exercise electrocardiography. Scintigraphy yielded a sensitivity of 84, 74 and 90% for one, two and three vessel disease, respectively. Noninvasive arm ergometry exercise-thallium imaging testing appears to be reliable and useful and should be considered in the evaluation of coronary artery disease in patients with lower limb impairment

  14. Cardiointegram: detection of coronary artery disease in males with chest pain and a normal resting electrocardiogram

    International Nuclear Information System (INIS)

    Teichholz, L.E.; Steinmetz, M.Y.; Escher, D.; Herman, M.V.; Naimi, S.; Mahony, D.V.; Ellestad, M.H.

    1986-01-01

    The cardiointegram is a non-invasive technique for the analysis of the electrical signals of the heart obtained by a transformation of the voltage vs. time format by a series of integrations. This multicenter study compares the results of the cardiointegram with coronary arteriography in 140 male patients with chest pain and a normal resting electrocardiogram. The cardiointegram was determined on two resting complexes of Leads I, II, V4, V5 and V6 and called abnormal if greater than or equal to four of ten complexes were abnormal, i.e., fell outside of a previously determined template of normality. The sensitivity was 73% and specificity was 78% for the diagnosis of occlusive coronary artery disease. When greater than or equal to five of ten abnormal complexes were used as the cut-off for an abnormal test and ''equivocal'' results (four of ten abnormal, n = 18) were excluded from analysis there was a sensitivity of 69% and specificity of 88%. Thirty-seven of 38 patients (97%) with an abnormal cardiointegram and a positive exercise stress test had coronary artery disease. Thus, the cardiointegram appears to be a useful non-invasive test for the detection of coronary artery disease in males with chest pain and a normal resting electrocardiogram in whom the diagnosis of coronary artery disease is being considered

  15. Noninvasive assessment of coronary stenoses by myocardial imaging during pharmacologic coronary vasodilation. VI. Detection of coronary artery disease in human beings with intravenous N-13 ammonia and positron computed tomography

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Wisenberg, G.; Phelps, M.E.; Gould, K.L.; Henze, E.; Hoffman, E.J.; Gomes, A.; Kuhl, D.E.

    1982-01-01

    The possibility of detecting mild coronary stenoses with positron computed tomography and nitrogen (N-13) ammonia administered during pharmacologic coronary vasodilation was previously demonstrated in chronically instrumented dogs. The feasibility of using this technique in human beings and its sensitivity in determining the degree and extent of coronary artery disease were examined in 13 young normal healthy volunteers and 32 patients with angiographically documented coronary artery disease. N-13 ammonia was administered intravenously and its distribution in the left ventricular myocardium recorded at rest and during dipyridamole-induced coronary hyperemia. In the 13 volunteers, N-13 activity was homogeneous at rest and during hyperemia, whereas 31 of the 32 patients had regional defects on the hyperemic images not present during rest. All six patients with double, all 10 with triple and 15 of 16 patients with single vessel disease (97 percent) were correctly identified with the technique. Two vessel involvement was correctly identified in five of the six patients with double vessel disease and three vessel disease in six of 10 patients. Of all 58 coronary stenoses, 52 (90 percent) were correctly identified. In a subgroup of 11 patients, the technique was compared with exercise thallium-201 planar images, which were abnormal in 10 (91 percent) whereas N-13 images were abnormal in all 11. Of the 19 stenosed coronary arteries in this subgroup, 11 (58 percent) were correctly identified with thallium-201 and 17 (89 percent) with tomography (p less than 0.01). It is concluded that cross-sectional imaging of the myocardial distribution of N-13 ammonia administered during pharmacologic coronary vasodilation is a highly sensitive and accurate means for noninvasive detection of coronary stenoses in human beings and for estimating the extent of coronary artery disease

  16. Clinical and angiographic profile of patients with markedly elevated coronary calcium scores (≥1000) detected by electron beam computed tomography

    International Nuclear Information System (INIS)

    Almeda, Francis Q.; Shah, Rima; Senter, Shaun; Kason, Thomas T.; Haynie, Justin; Calvin, James E.; Kavinsky, Clifford J.; Snell, R. Jeffrey; Schaer, Gary L.; McLaughlin, Vallerie V.

    2004-01-01

    Objective: The objective of this study was to determine the clinical and angiographic profile of patients with extremely high coronary artery calcium scores (CACS; ≥1000) by electron beam computed tomography (EBCT). Methods: All patients at Rush University Medical Center who had a calcium score ≥1000 and a coronary angiogram performed from 1997 to 2002 were identified using a prospectively collected database. The baseline demographics, symptom status, and degree of coronary stenosis by angiography and subsequent rate of coronary intervention were compared with that of patients with calcium scores <1000. Results: The clinical and angiographic profile of patients with severe coronary calcification, detected by EBCT, revealed that patients with scores ≥1000 had a significantly higher prevalence of coronary stenosis ≥50% compared with patients with scores <1000 (97% vs. 57%, P<.001). The group with CACS ≥1000 was more likely to be male (90% vs. 75%, P=.027) and was older (64±8 vs. 59±10, P=.001) compared with the group with less severe calcification. Although there was a significantly higher rate of luminal stenosis detected by coronary angiography in the cohort with CACS ≥1000, there was no difference in subsequent percutaneous coronary intervention (PCI) and utilization of intracoronary stents between the two groups. Conclusions: A markedly elevated coronary calcium score (≥1000) is correlated with increasing age and is associated with an increased likelihood of coronary stenosis ≥50%. However, the decision to perform coronary angiography in patients with severe coronary calcification should not be based solely on these findings, but should remain primarily dependent on the degree of ischemia detected by clinical and functional assessment

  17. Automatic detection of coronary arterial branches from X-ray angiograms

    International Nuclear Information System (INIS)

    Lu, Shan; Eiho, Shigeru

    1992-01-01

    This paper describes a method to trace the coronary arterial boundaries automatically from x-ray angiograms. We developed an automatic procedure to detect the edges of an artery with its branches. The edge point is evaluated by a function based on smoothing differential operator on a searching line which is obtained by using the continuous properties of the arterial edges. Thus the boundary points along the artery are detected automatically. If there exists a branch on the boundary, it can be detected automatically. This information about the branch is stored on the stack of the search information and will be used to detect the branch artery. In our edge detection process, the required user interaction is only the manual definition of a starting point for the search, the direction of the search and the range for search. We tested this method on some images generated by a computer with different stenoses and on a coronary angiogram. These results show that this method is useful for analyzing coronary angiograms. (author)

  18. The clinical value of adenosine triphosphate stress myocardial perfusion tomography for detecting coronary artery disease

    International Nuclear Information System (INIS)

    Yao Zhiming; He Qing; Qu Wanying; Yu Xue; Han Lijun; Yu Zhiguo; Li Wei; Zeng Xuezhai; Zhu Ming; Zhao Hongshan

    2002-01-01

    Objective: To study the clinical value of adenosine triphosphate stress myocardial perfusion tomography imaging (ATP-MPI) in detection of coronary artery disease (CAD). Methods: There were 278 patients underwent ATP-MPI, 51 patients of them also underwent coronary angiography (CAG). Seventy-three patients underwent stress-rest myocardial perfusion tomography imaging with multi-stage submaximal exercise test (ST-MPI) and CAG serving as control group. Results: 1) Side effects: there were 11 different symptoms and atrioventricular conduction block (10 patients), sinoatrial conduction block (2 patients) occurred during ATP stress. Allopathy or interruption of ATP stress did not happen. 2) The sensitivity and specificity of ATP-MPI in detection of CAD were 97.1% and 82.4%, respectively, and those in detection of ≥50% narrowing coronary artery were 91.0% and 94.7%, respectively. 3) In patients without myocardial infarction, the sensitivity and specificity of ATP-MPI in detection of myocardial ischemia were comparable to those of ST-MPI. Conclusion: ATP-MPI is an accurate, safe modality and is comparable to ST-MPI in the detection of CAD

  19. Detection and severity of coronary disease: comparison between Framingham and calcium scores using multi-slice tomography

    International Nuclear Information System (INIS)

    Rodriguez Gomez, Maria Liliana; Montenegro, Edison; Ruiz, Angela Maria; Ardila, Jaime

    2011-01-01

    Introduction: multiple studies have shown that the coronary calcium index is an independent, more accurate predictor of future coronary events in relation to traditional risk factors. However, these studies have not been conducted in populations of developing countries like Colombia. Objective: to compare the strength of association between the Framingham index and the coronary calcium score in detecting the presence and severity of coronary disease as defined by 64-channel multi-slice angio-CT in order to provide additional information for decision-making in our asymptomatic coronary population. Methodology: we reviewed the written reports of coronary angiography scans performed in past 3 years. Based on this information, bivariate (calculation of Spearman rho correlation coefficients) and multivariate (logistic regression) analyses were performed. Results: the coronary calcium score showed a higher correlation with the presence and severity of coronary disease, Spearman Rho coefficient, compared with the Framingham index, Spearman's Rho coefficient of 0.30 (p<0.001). The moderate Framingham index (10-19%) shows no strength of association with significant and non-significant coronary artery disease, OR = 2, 51 CI 95% (0.7-8.9) and OR = 2.3 CI 95% (0.86-6.15), respectively. Patients with calcium values = 100 showed significant strength of association, OR = 182, 95% (17.4 -190.2), with significant coronary disease compared with high Framingham index values (=20%), OR = 18.6, CI 95% (1.75-198). Conclusions: the coronary calcium score has a higher correlation with the presence and severity of coronary disease when compared with the Framingham index. There is a low correlation between the index and Framingham coronary calcium.

  20. Multidetector CT of the coronary imaging: assessment of image quality and accuracy in detecting stenoses

    International Nuclear Information System (INIS)

    Huang Meiping; Liu Qishun; Liu Hui; Liang Changhong; Zhang Shaobin

    2006-01-01

    Objective: To evaluate the image quality of 64-multi detector computed tomography (MDCT) and the clinical accuracy in detecting coronary artery lesions. Methods: One hundred and five patients were studied by MDCT. The results were compared with invasive coronary angiography (ICA). Patients were excluded for atrial fibrillation, but not for high heart rate, coronary calcification, or obesity. MDCT was analyzed with regard to image quality and presence of coronary artery lesions. Results: The data evaluation of the image quality was based on a total of 1365 segments (13 coronary segments for each patient), of which 1144 segments were considered to have diagnostic image quality, but 221 segments (16.2%) could not be sufficiently evaluated because of severe calcifications (153 segments) and motion artifacts (68 segments). The median calcium score [Agatston score equivalent (ASE)] was 154 (range 0--1983). 87 of the 105 patients had an ASE of less than 1,000 [median 105 (range 0-994)], and 18 patients had an ASE greater than 1000 [median 1477 (range 1115-1983)]. For detecting lesions with 50% or greater narrowing (without any exclusion criteria), the overall sensitivity, specificity, positive predictive value, and negative predictive value were 85.7%, 97.9%, 93.0%, and 95.5%, respectively. When limiting the number of patients to those with a calcium score of less than 1000 ASE, the threshold- corrected sensitivity for lesions with 50% or greater narrowing was 96.0%; specificity, 98.9%; positive predictive value, 95.3%; and negative predictive value, 99.0%. Conclusion: Our results indicate high quantitative and qualitative diagnostic accuracy of 64-slice MSCT in comparison to QCA in a broad spectrum of patients. (authors)

  1. Noninvasive detection of coronary artery bypass graft patency by intravenous electron beam computed tomographic angiography.

    Science.gov (United States)

    Yamakami, Shoji; Toyama, Junji; Okamoto, Mitsuhiro; Matsushita, Toyoaki; Murakami, Yoshimasa; Ogata, Masaki; Ito, Shigenori; Fukutomi, Tatsuya; Okayama, Naotsuka; Itoh, Makoto

    2003-11-01

    This study evaluates the usefullness of intravenous electron beam computed tomographic angiography (EBA) for the detection of coronary artery bypass graft patency in 43 patients (33 men and 10 women, mean age, 65 years) who had coronary artery bypass graft surgery. EBA was performed a few days before selective bypass graft angiography (SGA). Forty axial cross-sections of angiographic images of the heart were acquired consecutively by an electrocardiographic trigger signal at 40% of the RR interval, which corresponds to the end-systolic phase. EBA data were reconstructed as a three-dimensional shaded surface display of the heart and bypass grafts. Detectability of the patency of bypass gratis was evaluated, taking selective angiographic images of the bypass grafts as a gold standard. One hundred and nine grafts (96%) out of 114 grafts were subjected to evaluation: 37 grafts were left internal mammary artery grafts (LIMA), 7 were right internal mammary artery grafts (RIMA), 6 were gastroepiploic artery grafts (GEA), 7 were free gastroepiploic artery grafts with venous drainage (free-GEA), 7 were radial artery grafts (RAG), and 45 were saphenous vein gratis (SVG). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBA were 98%, 100%, 100%, 91%, and 98%, respectively. EBA sampled at the end-systolic period was determined to be useful for the detection of coronary artery bypass graft patency and occlusion.

  2. Accuracy of detecting stenotic changes on coronary cineangiograms using computer image processing

    International Nuclear Information System (INIS)

    Sugahara, Tetsuo; Kimura, Koji; Maeda, Hirofumi.

    1990-01-01

    To accurately interprets stenotic changes on coronary cineangiograms, an automatic method of detecting stenotic lesion using computer image processing was developed. First, tracing of artery was performed. The vessel edges were then determined by unilateral Gaussian fitting. The stenotic change was detected on the basis of the reference diameter estimated by Hough transformation. This method was evaluated in 132 segments of 27 arteries in 18 patients. Three observers carried out visual interpretation and computer-aided interpretation. The rate of detection by visual interpretation was 6.1, 28.8 and 20.5%, and by computer-aided interpretation, 39.4, 39.4 and 45.5%. With computer-aided interpretation, the agreement between any two observers on lesions and non-lesions was 40.2% and 59.8%, respectively. Therefore, visual interpretation tended to underestimate the stenotic changes on coronary cineangiograms. We think that computer-aided interpretation increase the reliability of diagnosis on coronary cineangiograms. (author)

  3. Myocardial perfusion imaging for the detection of coronary heart disease

    International Nuclear Information System (INIS)

    Strauss, H.W.; Cook, D.J.; Bailey, I.; Rouleau, J.; Pitt, B.

    1976-01-01

    A method of myocardial perfusion imaging using 201 Tl is described. Thallium is able to substitute for potassium in biological systems including transport by the sodium--potassium ATP-ase system. The high extraction efficiency of the heart for 201 Tl offers a method whereby a tracer may be administered intravenously and is concentrated to a significant degree by the heart. However, only about 3 to 4 percent of the dose administered lodges in the myocardium. Experiments with dogs indicated that the regional distribution of Tl in the heart reflects the regional distribution of blood flow. The goal is to develop a procedure that can detect those patients with significant disease prior to the onset of a catastrophic event and studies are being undertaken to improve the sensitivity of the method for the detection of smaller lesions in the myocardium

  4. Early detection of lung cancer using ultra-low-dose computed tomography in coronary CT angiography scans among patients with suspected coronary heart disease.

    Science.gov (United States)

    Zanon, Matheus; Pacini, Gabriel Sartori; de Souza, Vinicius Valério Silveiro; Marchiori, Edson; Meirelles, Gustavo Souza Portes; Szarf, Gilberto; Torres, Felipe Soares; Hochhegger, Bruno

    2017-12-01

    To assess whether an additional chest ultra-low-dose CT scan to the coronary CT angiography protocol can be used for lung cancer screening among patients with suspected coronary artery disease. 175 patients underwent coronary CT angiography for assessment of coronary artery disease, additionally undergoing ultra-low-dose CT screening to early diagnosis of lung cancer in the same scanner (80kVp and 15mAs). Patients presenting pulmonary nodules were followed-up for two years, repeating low-dose CTs in intervals of 3, 6, or 12 months based on nodule size and growth rate in accordance with National Comprehensive Cancer Network guidelines. Ultra-low-dose CT identified 71 patients with solitary pulmonary nodules (41%), with a mean diameter of 5.50±4.00mm. Twenty-eight were >6mm, and in 79% (n=22) of these cases they were false positive findings, further confirmed by follow-up (n=20), resection (n=1), or biopsy (n=1). Lung cancer was detected in six patients due to CT screening (diagnostic yield: 3%). Among these, four cases could not be detected in the cardiac field of view. Most patients were in early stages of the disease. Two patients diagnosed at advanced stages died due to cancer complications. The addition of the ultra-low-dose CT scan represented a radiation dose increment of 1.22±0.53% (effective dose, 0.11±0.03mSv). Lung cancer might be detected using additional ultra-low-dose protocols in coronary CT angiography scans among patients with suspected coronary artery disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography.

    Science.gov (United States)

    Kirişli, H A; Schaap, M; Metz, C T; Dharampal, A S; Meijboom, W B; Papadopoulou, S L; Dedic, A; Nieman, K; de Graaf, M A; Meijs, M F L; Cramer, M J; Broersen, A; Cetin, S; Eslami, A; Flórez-Valencia, L; Lor, K L; Matuszewski, B; Melki, I; Mohr, B; Oksüz, I; Shahzad, R; Wang, C; Kitslaar, P H; Unal, G; Katouzian, A; Örkisz, M; Chen, C M; Precioso, F; Najman, L; Masood, S; Ünay, D; van Vliet, L; Moreno, R; Goldenberg, R; Vuçini, E; Krestin, G P; Niessen, W J; van Walsum, T

    2013-12-01

    Though conventional coronary angiography (CCA) has been the standard of reference for diagnosing coronary artery disease in the past decades, computed tomography angiography (CTA) has rapidly emerged, and is nowadays widely used in clinical practice. Here, we introduce a standardized evaluation framework to reliably evaluate and compare the performance of the algorithms devised to detect and quantify the coronary artery stenoses, and to segment the coronary artery lumen in CTA data. The objective of this evaluation framework is to demonstrate the feasibility of dedicated algorithms to: (1) (semi-)automatically detect and quantify stenosis on CTA, in comparison with quantitative coronary angiography (QCA) and CTA consensus reading, and (2) (semi-)automatically segment the coronary lumen on CTA, in comparison with expert's manual annotation. A database consisting of 48 multicenter multivendor cardiac CTA datasets with corresponding reference standards are described and made available. The algorithms from 11 research groups were quantitatively evaluated and compared. The results show that (1) some of the current stenosis detection/quantification algorithms may be used for triage or as a second-reader in clinical practice, and that (2) automatic lumen segmentation is possible with a precision similar to that obtained by experts. The framework is open for new submissions through the website, at http://coronary.bigr.nl/stenoses/. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Sensibility and specificity of the stress echocardiography with Dobutamine for the detection of coronary disease

    International Nuclear Information System (INIS)

    Senior, Juan Manuel; Escobar, Carlos Ignacio; Jaramillo, Mario and others

    2001-01-01

    Dobutamine stress echocardiography has become a useful method for detecting coronary artery disease in the high prevalence population. The reported sensitivity varies between 76-90% and the specificity between 60-95%. 60-95% there have been few reports regarding sensitivity and specificity among our population. The aim of this study was to evaluate the sensitivity of dopamine stress echocardiography in a population with a high probability of coronary disease. This was a randomized retrospective-prospective study. Between February 1 of 1998 and February 1 of 1999. 409 patients underwent dopamine stress echocardiography and were analyzed according to established protocol. The Dobutamine stress echocardiography as well as the angiography was checked in a blind form by one of the participating researchers trained in those procedures. The diagnostic concordance was found to be greater than 90%. Significant coronary disease was considered to be present in those cases in which there was severe stenosis greater than 50% in a major epicardial artery or greater than 40 % in the left main artery. Coronary arteriography was performed within three months of Dobutamine stress echocardiography imaging. A sixteen-segment model was used as the index for the evaluation of systolic wall thickening and the results were classified as follows: normal (l), ischemia (ll), fixed abnormality (lll) and mixed (lV). 409 patients with an average age of 62.8 +/- 12) were included in the study at random. Six patients with mediocre technical examinations were excluded. 47 % were male. 29% had a history of myocardial infarction, 35 % had a history of arterial hypertension and 10% had diabetes mellitus. The average ejection fraction was 54 +/- 13%. The examination was prescribed in order to detect the presence of ischemia in 95.8% of the cases and as part of preoperative evaluation in 4.2 %. There were adverse effects in 40% of the cases; 15% of these were systemic and 25 % cardiac. The test was

  7. Learning-based automatic detection of severe coronary stenoses in CT angiographies

    Science.gov (United States)

    Melki, Imen; Cardon, Cyril; Gogin, Nicolas; Talbot, Hugues; Najman, Laurent

    2014-03-01

    3D cardiac computed tomography angiography (CCTA) is becoming a standard routine for non-invasive heart diseases diagnosis. Thanks to its high negative predictive value, CCTA is increasingly used to decide whether or not the patient should be considered for invasive angiography. However, an accurate assessment of cardiac lesions using this modality is still a time consuming task and needs a high degree of clinical expertise. Thus, providing automatic tool to assist clinicians during the diagnosis task is highly desirable. In this work, we propose a fully automatic approach for accurate severe cardiac stenoses detection. Our algorithm uses the Random Forest classi cation to detect stenotic areas. First, the classi er is trained on 18 CT cardiac exams with CTA reference standard. Then, then classi cation result is used to detect severe stenoses (with a narrowing degree higher than 50%) in a 30 cardiac CT exam database. Features that best captures the di erent stenoses con guration are extracted along the vessel centerlines at di erent scales. To ensure the accuracy against the vessel direction and scale changes, we extract features inside cylindrical patterns with variable directions and radii. Thus, we make sure that the ROIs contains only the vessel walls. The algorithm is evaluated using the Rotterdam Coronary Artery Stenoses Detection and Quantication Evaluation Framework. The evaluation is performed using reference standard quanti cations obtained from quantitative coronary angiography (QCA) and consensus reading of CTA. The obtained results show that we can reliably detect severe stenosis with a sensitivity of 64%.

  8. Noninvasive detection of coronary abnormalities in pediatric patients with Kawassaki disease using multi-slice spiral CT

    International Nuclear Information System (INIS)

    Hou Yang; Guo Wenli; Yue Yong; Chen Liying; Guo Qiyong; Yu Xianyi; Wang Hong

    2006-01-01

    Objective: To evaluate the feasibility and value of detecting coronary artery lesions in Kawasaki disease using multi-slice computed tomography (MSCT). Methods: Thirty-four pediatric patients underwent 16-slice or 64-slice CT coronary, angiography. 18 patients were also examined with 2 dimension echocardiography (2DE). In all cases, visibility of coronary artery segment was recorded. The diameter of the LCA, RCA were measured in MSCTA and compared with 2DE. Correlation coefficient of dimension and coincidence rate of two methods were calculated. Results: Coronary artery lesions were found in 14 patients (22 branches) of the 34 cases with KD on MSCT. Six cases were dialated, 3 cases were dialated with aneurysms, 2 cases had aneurysms without dialation. Coronary artery stenosis in 1 eases, calcification in 2 cases. Three cases had multiple aneurysms with the presence of alternate stenosis that made the artery a bead-like appearance. CC of LM and RCA were 0.85, 0.91, respectively (P>0.05). Three coronary artery aneurysm in the distal RCA was missed by 2DE. MSCT could not detect slight or moderate mitral regurgitation in 2 patients and artery wall thickening in 5 patients. Conclusion: MSCT would be an effective complementary or alternative method for CDEC to evaluate coronary artery lesions non-invasively in pediatric patients with Kawasaki disease. (authors)

  9. Problems of detection method of coronary arterial stenosis on cineangiograms by computer image processing

    International Nuclear Information System (INIS)

    Sugahara, Tetsuo; Yanagihara, Yoshio; Sugimoto, Naozou; Uyama, Chikao; Maeda, Hirofumi.

    1988-01-01

    For the evaluation of the coronary arterial stenosis (CAS), the detection method of CAS were estimated on the coronary cineangiograms by computer image processing. For correlation of the accuracy of measurement of diameter on the image of resolution of 30 and 4 μm/pixel were measured the diameter on the vessel model images using sum of first and second differential method. The accuracy of measurement on resolution image of 30 and 4 μm/pixel on 3 mm diameter is 4.7 % and 2.3 %, respectively. Threshold method was used for the detection of the arterial wall on the subtraction images. For the detection of CAS, measurement method of the branch segment and determination method of the radius and normal vessel diameter were evaluated. A matter of special importance is determination method of the normal diameter. In view of the fact that this is a matter of great importance, it caused error to the measurement of prerent stenosis and stenotic length. This resulted that the detection of CAS was important not only the accuracy of measurement of the vessel diameter but also determination method of the normal diameter. (author)

  10. Detection of coronary artery disease - comparison of exercise stress radionuclide angiocardiography and thallium stress perfusion scanning

    International Nuclear Information System (INIS)

    Jengo, J.A.; Freeman, R.; Brizendine, M.; Mena, I.; St. Mary Medical Center, Long Beach, Calif.)

    1980-01-01

    Exercise thallium scanning and stress radionuclide angiography were compared in 16 normal subjects and 42 patients with more than 75% coronary arterial obstruction in studies using upright exercise on a bicycle ergometer. Studies at rest were subsequently obtained. Exercise thallium scans in the control group were normal in 15 and showed a defect in 1. Ejection fraction increased in all 16. During exercise, regional wall motion increased uniformly. In the group with coronary artery disease, thallium scanning revealed a new defect in the distribution of the involved arteries in 24 patients. In 15 who had a defect at rest, no new defect developed, but in 9 of the 15 new segmental wall motion defects were evident on radionuclide angiography. With exercise, ejection fraction decreased slightly. Regional wall motion abnormalities developed in the areas corresponding to thallium defects in all. Thallium scanning had a 93% and radionuclide angiography a 98% sensitivity value in detecting coronary artery disease. The respective specificity values were 94 and 100%. In patients with prior myocardial infarction who manifested new exercise abnormalities, 50% showed new thallium defects and 81% new wall motion defects

  11. Scintigraphic detection of coronary artery thrombi in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Fox, K.A.; Bergmann, S.R.; Mathias, C.J.; Powers, W.J.; Siegel, B.A.; Welch, M.J.; Sobel, B.E.

    1984-01-01

    To determine whether coronary thrombi can be detected scintigraphically after acute myocardial infarction, 24 patients were studied with a new method employing indium-111-labeled platelets and technetium-99m-labeled red blood cells. Nine patients with suspected infarction were evaluated initially within 9 hours of the onset of symptoms and again 18 to 24 hours after onset. Foci of net indium accumulation were detected after image processing that incorporated subtraction of blood pool activity. Carotid and pulmonary artery reference regions, in which blood pool activity is high and active platelet deposition unlikely, were used to correct digitized cardiac scintigrams for indium-111 platelet activity in the blood pool. In patients with infarction, distinct foci of net indium accumulation were present in regions corresponding to the coronary artery supplying ischemic zones. This occurred in seven of eight patients at the time of the earliest evaluation after the onset of symptoms) and in eight of nine patients at the time of subsequent imaging (23.6 +/- 1.9 hours after onset). Only 1 of 15 control patients exhibited a cardiac focus of net indium accumulation. The percent of indium excess (100 [total indium-111 activity-blood pool indium-111 activity]/blood pool indium-111 activity) within the cardiac region measured (+/- SD) 16.8 +/- 11.6% in all patients with myocardial infarction (19.1 +/- 11.2% in those with visually identified foci) compared with 0.4 +/- 4.3% in control patients. This method permits early detection and sequential assessment of coronary artery thrombi

  12. Non-invasive detection of coronary endothelial response to sequential handgrip exercise in coronary artery disease patients and healthy adults.

    Directory of Open Access Journals (Sweden)

    Allison G Hays

    Full Text Available OBJECTIVES: Our objective is to test the hypothesis that coronary endothelial function (CorEndoFx does not change with repeated isometric handgrip (IHG stress in CAD patients or healthy subjects. BACKGROUND: Coronary responses to endothelial-dependent stressors are important measures of vascular risk that can change in response to environmental stimuli or pharmacologic interventions. The evaluation of the effect of an acute intervention on endothelial response is only valid if the measurement does not change significantly in the short term under normal conditions. Using 3.0 Tesla (T MRI, we non-invasively compared two coronary artery endothelial function measurements separated by a ten minute interval in healthy subjects and patients with coronary artery disease (CAD. METHODS: Twenty healthy adult subjects and 12 CAD patients were studied on a commercial 3.0 T whole-body MR imaging system. Coronary cross-sectional area (CSA, peak diastolic coronary flow velocity (PDFV and blood-flow were quantified before and during continuous IHG stress, an endothelial-dependent stressor. The IHG exercise with imaging was repeated after a 10 minute recovery period. RESULTS: In healthy adults, coronary artery CSA changes and blood-flow increases did not differ between the first and second stresses (mean % change ±SEM, first vs. second stress CSA: 14.8%±3.3% vs. 17.8%±3.6%, p = 0.24; PDFV: 27.5%±4.9% vs. 24.2%±4.5%, p = 0.54; blood-flow: 44.3%±8.3 vs. 44.8%±8.1, p = 0.84. The coronary vasoreactive responses in the CAD patients also did not differ between the first and second stresses (mean % change ±SEM, first stress vs. second stress: CSA: -6.4%±2.0% vs. -5.0%±2.4%, p = 0.22; PDFV: -4.0%±4.6% vs. -4.2%±5.3%, p = 0.83; blood-flow: -9.7%±5.1% vs. -8.7%±6.3%, p = 0.38. CONCLUSION: MRI measures of CorEndoFx are unchanged during repeated isometric handgrip exercise tests in CAD patients and healthy adults. These findings

  13. Detection of Human Cytomegalovirus and Epstein-Barr Virus in Coronary Atherosclerotic Tissue

    Science.gov (United States)

    Imbronito, Ana Vitória; Marcelino, Silvia Linardi; Grande, Sabrina Rosa; Nunes, Fabio Daumas; Romito, Giuseppe Alexandre

    2010-01-01

    Previous studies indicated that patients with atherosclerosis are predominantly infected by human cytomegalovirus (HCMV), but rarely infected by type 1 Epstein-Barr virus (EBV-1). In this study, atheromas of 30 patients who underwent aortocoronary bypass surgery with coronary endartherectomy were tested for the presence of these two viruses. HCMV occurred in 93.3% of the samples and EBV-1 was present in 50% of them. Concurrent presence of both pathogens was detected in 43.3% of the samples. PMID:24031529

  14. MRI: A method to detect minor brain damage following coronary bypass surgery

    Energy Technology Data Exchange (ETDEWEB)

    Vik, A.; Brubakk, A.O. (Trondheim Univ. (Norway). Dept. of Biomedical Engineering); Rinck, P.A. (Trondheim Univ. (Norway). MR Center); Sande, E.; Levang, O.W. (Trondheim Univ. Hospital (Norway). Dept. of Surgery); Sellevold, O. (Trondheim Univ. Hospital (Norway). Dept. of Anaesthesiology)

    1991-10-01

    In order to assess the occurrence of minor focal brain lesions after coronary bypass surgery, magnetic resonance imaging (MRI) was used. Nine male patients (age 42-63) with angina pectoris were investigated at 0.5 Tesla. The investigation was performed one to seven weeks prior to the operation and one month after the operation. Before surgery, the images demonstrated more than five high intensity spots in the white matter of the brain in all but two patients. No additional spots were found after operation. This pilot study indicates that it might be difficult to use MRI to detect minor parenchymal lesions after cardiopulmonary bypass surgery. (orig.).

  15. Noninvasive detection of coronary vasospastic angina using a double-acquisition coronary CT angiography protocol in the presence and absence of an intravenous nitrate: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun-Ju; Kim, Dong Won; Yoon, Seong Kuk; Lee, Ki-Nam [Dong-A University, Department of Radiology, College of Medicine, Busan (Korea, Republic of); Kim, Moo Hyun; Jin, Cai De [Dong-A University, Department of Cardiology, College of Medicine, Busan (Korea, Republic of); Dong-A University Hospital, Global Clinical Trial Center, Busan (Korea, Republic of); Seo, Jeongmin; Park, Tae-Ho [Dong-A University, Department of Cardiology, College of Medicine, Busan (Korea, Republic of); Choi, Sang Il [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si (Korea, Republic of); Yoon, Yeonyee Elizabeth [Seoul National University Bundang Hospital, Department of Cardiology, Seongnam-si (Korea, Republic of)

    2017-03-15

    To evaluate the feasibility of a double-acquisition coronary CT angiography (CCTA) protocol in the presence and absence of an intravenous (IV) vasodilator infusion for detecting vasospastic angina. Twenty patients with a high clinical probability of vasospastic angina were enrolled. All subjects underwent baseline CCTA without a vasodilator in the early morning followed by a catheterized coronary angiography with ergonovine provocation test. Within 3 days, all subjects underwent repeat CCTA during a continuous IV infusion of nitrate. Vasospastic angina as detected by CCTA was defined as significant stenosis (≥50 %) with negative remodelling without definite plaques or diffuse small diameter (<2 mm) of a major coronary artery with a beaded appearance on baseline CT that completely dilated on IV nitrate CT. The CCTA results were compared to the catheterized ergonovine provocation test as the reference standard. Among 20 patients, the catheterized ergonovine provocation test detected vasospasm in 15 patients. The sensitivity, specificity, positive predictive value and negative predictive value of CCTA in a per-patient-based analysis were 73, 100, 100 and 56 %, respectively. Double-acquisition CCTA in the presence and absence of IV infusion of nitrate allows noninvasive detection of vasospastic angina with moderate sensitivity and high specificity. (orig.)

  16. Comparison of traditional cardiovascular risk models and coronary atherosclerotic plaque as detected by computed tomography for prediction of acute coronary syndrome in patients with acute chest pain.

    Science.gov (United States)

    Ferencik, Maros; Schlett, Christopher L; Bamberg, Fabian; Truong, Quynh A; Nichols, John H; Pena, Antonio J; Shapiro, Michael D; Rogers, Ian S; Seneviratne, Sujith; Parry, Blair Alden; Cury, Ricardo C; Brady, Thomas J; Brown, David F; Nagurney, John T; Hoffmann, Udo

    2012-08-01

    The objective was to determine the association of four clinical risk scores and coronary plaque burden as detected by computed tomography (CT) with the outcome of acute coronary syndrome (ACS) in patients with acute chest pain. The hypothesis was that the combination of risk scores and plaque burden improved the discriminatory capacity for the diagnosis of ACS. The study was a subanalysis of the Rule Out Myocardial Infarction Using Computer-Assisted Tomography (ROMICAT) trial-a prospective observational cohort study. The authors enrolled patients presenting to the emergency department (ED) with a chief complaint of acute chest pain, inconclusive initial evaluation (negative biomarkers, nondiagnostic electrocardiogram [ECG]), and no history of coronary artery disease (CAD). Patients underwent contrast-enhanced 64-multidetector-row cardiac CT and received standard clinical care (serial ECG, cardiac biomarkers, and subsequent diagnostic testing, such as exercise treadmill testing, nuclear stress perfusion imaging, and/or invasive coronary angiography), as deemed clinically appropriate. The clinical providers were blinded to CT results. The chest pain score was calculated and the results were dichotomized to ≥10 (high-risk) and modeling was performed to examine the association of risk scores and coronary plaque burden to the outcome of ACS. Unadjusted models were individually fitted for the coronary plaque burden and for Goldman, Sanchis, TIMI, and chest pain scores. In adjusted analyses, the authors tested whether the association between risk scores and ACS persisted after controlling for the coronary plaque burden. The prognostic discriminatory capacity of the risk scores and plaque burden for ACS was assessed using c-statistics. The differences in area under the receiver-operating characteristic curve (AUC) and c-statistics were tested by performing the -2 log likelihood ratio test of nested models. A p value capacity for the diagnosis of ACS. Plaque burden was

  17. Relationship between the arterial calcification detected in mammography and coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Topal, Ugur [Department of Radiology, Uludag University, Medical School, Goeruekle Campus, 16059 Bursa (Turkey)], E-mail: utopal@uludag.edu.tr; Kaderli, Aysel [Department of Cardiology, Uludag University, Medical School, Goeruekle Campus, 16059 Bursa (Turkey); Topal, Naile Bolca [Department of Radiology, Uludag University, Medical School, Goeruekle Campus, 16059 Bursa (Turkey); Ozdemir, Buelent; Yesilbursa, Dilek; Cordan, Jale [Department of Cardiology, Uludag University, Medical School, Goeruekle Campus, 16059 Bursa (Turkey); Ediz, Buelent [Department of Statistics, Uludag University, Medical School, Goeruekle Campus, 16059 Bursa (Turkey); Aydinlar, Ali [Department of Cardiology, Uludag University, Medical School, Goeruekle Campus, 16059 Bursa (Turkey)

    2007-09-15

    Objective: Arterial calcification is frequently encountered in mammography. The frequency of breast arterial calcification (BAC) increases with increasing age. Studies have shown that BAC is seen more frequently among the people who are under the risk of coronary artery diseases (CAD) such as diabetes and hypertension. The objective of this study is to investigate the relationship between the arterial calcification detected in mammography and the CAD. Material and methods: Screening mammography was performed in 123 women above the age of 40 years who had been examined with coronary angiography for the evaluation of CAD. The presence of BAC, number of affected vessels, and the distribution of calcification in the vessel wall were evaluated in the mammography. Subjects were questioned in terms of the cardiovasculary risk factors. The severity of CAD was evaluated according to the Gensini scoring. In addition, the number of blood vessels with stenosis of more than 50% was used as the vascular score. The correlation between Gensini and the vascular scores, and BAC was statistically evaluated using Mann-Whitney U and Kruskal-Wallis tests. Results: Eighty (65%) of 123 patients had CAD. BAC was detected in the mammography of 49 (39.8%) subjects. The ages and duration of menopause of the cases with BAC were significantly higher than those without BAC (p < 0.001). There was an almost significant correlation between the BAC and Gensini scores (p = 0.059). There was a significant increase in the frequency of BAC among subjects with more than two vessels with stenosis (p = 0.033). Conclusion: Frequency of BAC increases with increasing age. BAC is also frequently seen in subjects having severe coronary artery disease. Although increasing age may be a factor increasing the frequency of BAC, BAC may also be an indicator of CAD. Therefore, the mentioning of arterial calcification in mammography reports may be important in warning the clinician in terms of CAD.

  18. Accuracy of multidetector row computed tomography for the detection of transplant vasculopathy: comparison with invasive coronary angiography and intravascular ultrasound

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Carrascosa, J.; Perrone, S.; Deviggiano, A.; Lopez, E.M.; Lev, G.; Garcia, M.J.

    2009-01-01

    Objective: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for detection of luminal stenosis and cardiac allograft vasculopathy in comparison with coronary angiography (CA) and intravascular ultrasound (IVUS) respectively. Material and methods: Nineteen cardiac transplant patients scheduled for follow-up CA were included. MDCT coronary angiography was performed using a 16-row CT scanner within 7-14 days after CA and IVUS. Studies were analyzed by independent readers; two observers evaluated the CT datasets for the presence of coronary artery stenosis > 50% and allograft vasculopathy. Results: The sensitivity for detecting > 50% luminal stenosis was 80-88% and specificity, 98-99% and for detection of cardiac allograft vasculopathy, the sensitivity was 91-96% and specificity, 88-91%. Conclusion: In this preliminary series, our results indicate that MDCT coronary angiography was capable of detecting both significant coronary stenosis as well as diffuse intimal proliferation. This non-invasive procedure could be an alternative to CA and IVUS in the surveillance of heart transplant patients. (authors) [es

  19. Magnetic resonance pharmacological stress for detecting coronary disease. Comparison with echocardiography

    International Nuclear Information System (INIS)

    Baer, F.M.; Crnac, J.; Jochims, M.; Schneider, C.; Erdmann, E.; Schmidt, M.; Theissen, P.; Schicha, H.

    2000-01-01

    Stress testing is the cornerstone in the diagnosis of patients with suspected coronary artery disease (CAD). Although exercise ECG remains the primary approach for the detection of ischemia in patients with chest pain syndromes, its sensitivity and specificity is limited and exercise ECG does not provide detailed information about the localisation and extent of CAD. Stress echocardiography has been used for the detection of ischemia for more than a decade and has become an increasingly popular noninvasive method for the detection of CAD. In experienced hands wall motion analysis based on stress echocardiography has proved to be as sensitive and specific for the detection of myocardial ischemia as scintigraphic techniques. Recent technical improvements, namely the availability of ultrafast imaging sequences with a significant reduction of imaging time have initiated several studies which examined the combination of pharmacological stress and magnetic resonance imaging (MRI) for the detection of suspected CAD. The most well developed stress-MRI technique is wall motion imaging during dobutamine stress. This technique is analogous to stress echocardiography, but MRI has the inherent advantages of better resolution, higher reproducibility and true long and short axis imaging with contiguous parallel slices. However, the clinical impact of MRI for the diagnosis of CAD is still low. Further technical developments including real time imaging and a reliable automated quantitative analysis of left ventricular function are required before stress-MRI becomes a serious challenge to stressechocardiography in the clinical arena. Currently, only a few MRI facilities and physicians are dedicated to pharmacological stress testing with MRI and the future clinical impact of this promising technique will depend on its potential to provide information beyond myocardial function including perfusion, metabolism and coronary anatomy in form of a ''one-stop''-shop for the cardiac patient

  20. One-hour protocol stress myocardial scintigraphy. Prospective study of diagnostic accuracy for the detection of coronary artery stenosis

    International Nuclear Information System (INIS)

    Matsuda, Junko; Miyamoto, Nobuhide; Onitsuka, Hisamitsu; Ikushima, Ippei; Unoki, Toshihide; Takenaga, Makoto; Koiwaya, Yasushi; Eto, Tanenao

    1999-01-01

    A one-hour protocol for stress myocardial scintigraphy using technetium-99m-tetrofosmin (Tc-tetrofosmin) was compared with coronary arteriography for the detection of coronary artery stenosis in 90 consecutive patients without prior myocardial infarction, revascularization procedure or vasospastic angina. Tc-tetrofosmin stress myocardial scintigraphy acquired a rest image 20 min after intravenous administration of Tc-tetrofosmin (185 MBq, 1/5 vial) using a three-head gamma camera collecting 20-sec views over 360 deg. The stress test using bicycle ergometer was performed and administration of Tc-tetrofosmin (740 MBq, 4/5 vial) was repeated at the peak stress point. The stress image was acquired 15 min after the second injection with 5-sec views over 360 deg. Coronary arteriography revealed the presence of significant coronary artery stenosis (>75%) in 56 vessels of 45 patients, including 35 patients with single-vessel disease, 5 with two-vessel disease, 2 with three-vessel disease, and 3 with left main trunk disease. The overall sensitivity and specificity for the detection of coronary artery disease by visual analysis were 91.1% and 77.8%, respectively, and by quantitative analyses (using bull's-eye method) were 95.6% and 91.1%, respectively. The individual stenotic vessel sensitivities in the right coronary artery, left anterior descending artery, and left circumflex artery were 84.6%, 90.9%, and 78.6%, respectively. The specificities were 97.3%, 95.9%, and 100.0%, respectively. These results suggest that stress myocardial scintigraphy using the present new protocol is a promising approach for the detection of coronary artery stenosis. (author)

  1. Adaptive Ridge Point Refinement for Seeds Detection in X-Ray Coronary Angiogram

    Directory of Open Access Journals (Sweden)

    Ruoxiu Xiao

    2015-01-01

    Full Text Available Seed point is prerequired condition for tracking based method for extracting centerline or vascular structures from the angiogram. In this paper, a novel seed point detection method for coronary artery segmentation is proposed. Vessels on the image are first enhanced according to the distribution of Hessian eigenvalue in multiscale space; consequently, centerlines of tubular vessels are also enhanced. Ridge point is extracted as candidate seed point, which is then refined according to its mathematical definition. The theoretical feasibility of this method is also proven. Finally, all the detected ridge points are checked using a self-adaptive threshold to improve the robustness of results. Clinical angiograms are used to evaluate the performance of the proposed algorithm, and the results show that the proposed algorithm can detect a large set of true seed points located on most branches of vessels. Compared with traditional seed point detection algorithms, the proposed method can detect a larger number of seed points with higher precision. Considering that the proposed method can achieve accurate seed detection without any human interaction, it can be utilized for several clinical applications, such as vessel segmentation, centerline extraction, and topological identification.

  2. Prevalence of Coronary Artery Intramyocardial Course in a Large Population of Clinical Patients Detected by Multislice Computed Tomography Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    De Rosa, R.; Sacco, M.; Tedeschi, C.; Pepe, R.; Capogrosso, P.; Montemarano, E.; Rotondo, A.; Runza, G.; Midiri, M.; Cademartiri, F. (UO di Radiologia, Ospedale San Gennaro, Napoli (Italy))

    2008-10-15

    Background: Intramyocardial course, an inborn coronary anomaly, is defined as a segment of a major epicardial coronary artery that runs intramurally through the myocardium; in particular, we distinguish myocardial bridging, in which the vessel returns to an epicardial position after the muscle bridge, and intramyocardial course, which is described as a vessel running and ending in the myocardium. Purpose: To evaluate the prevalence of myocardial bridging and intramyocardial course of coronary arteries as defined by multidetector computed tomography (MDCT) angiography. Material and Methods: The study population consisted of 242 consecutive patients (211 men, 31 women; mean age 59+-6 years) with atypical chest pain admitted to our hospital between December 2004 and September 2006. All MDCT examinations were performed using a 16-detector-row scanner (Aquilion 16 CFX; Toshiba Medical System, Tokyo, Japan). Patients with heart rate above 65 bpm received 50 mg atenolol orally for 3 days prior to the MDCT scan, or they increased their usual therapy with beta-blockers, in order to obtain a prescan heart rate <60 bpm. Curved multiplanar and 3D volume reconstructions were performed to explore coronary anatomy. Results: In 235 patients, the CT scan was successful and images were appropriate for evaluation. The prevalence of myocardial bridging and intramyocardial course of coronary arteries was 18.7% (47 cases) in our patient population. In 30 segments (63.8%), the vessels ran and ended in the myocardium. In the remaining 17 segments (36.2%), the vessels returned to an epicardial position after the muscle bridge. We found no difference in the prevalence of this inborn coronary anomaly when comparing different clinical characteristics of the study population (sex, age, body-mass index [BMI], etc.). The mean length of the subepicardial artery was 7 mm (range 5-12 mm), and the mean depth in the diastolic phase was 1.9 mm (range 1.2-2.3 mm). There was no significant difference of

  3. Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT

    NARCIS (Netherlands)

    van Ooijen, P.M.A.; Dorgelo, J.; Zijlstra, F.; Oudkerk, M.

    2004-01-01

    Early identification and evaluation of relatively frequent anomalous coronary anatomy is quite relevant because of the occurrence of sudden cardiac death or related symptoms of myocardial ischemia. Selective coronary angiography (CAG) is invasive, expensive and cannot always provide the required

  4. A microcosting study of diagnostic tests for the detection of coronary artery disease in the Netherlands

    International Nuclear Information System (INIS)

    Tan, S.S.; Oppe, M.; Zoet-Nugteren, S.K.; Niezen, R.A.; Kofflard, M.J.M.; Ten Cate, F.J.; Roijen, L. Hakkaart-van

    2009-01-01

    Objective: The primary aim of the present study was to calculate the actual costs of four diagnostic tests for the detection of coronary artery disease in the Netherlands using a microcosting methodology. As a secondary objective, the cost effectiveness of eight diagnostic strategies was examined, using microcosting and reimbursement fees subsequently as the cost estimate. Design: A multicenter, retrospective cost analysis from a hospital perspective. Setting: The study was conducted in three general hospitals in the Netherlands for 2006. Interventions: Exercise electrocardiography (exECG), stress echocardiography (sECHO), single-photon emission computed tomography (SPECT) and coronary angiography (CA). Results: The actual costs of exECG, sECHO, SPECT and CA were Euro 33, 216, 614 and 1300 respectively. For all diagnostic tests, labour and indirect cost components (overheads and capital) together accounted for over 75% of the total costs. Consumables played a relatively important role in SPECT (14%). Hotel and nutrition were only applicable to SPECT and CA. Diagnostic services were solely performed for CA, but their costs were negligible (2%). Using microcosting estimates, exECG-sECHO-SPECT-CA was the most and CA the least cost effective strategy ( Euro 397 and 1302 per accurately diagnosed patient). Using reimbursement fees, exECG-sECHO-CA was most and SPECT-CA least cost effective ( Euro 147 and 567 per accurately diagnosed patient). Conclusions: The use of microcosting estimates instead of reimbursement fees led to different conclusions regarding the relative cost effectiveness of alternative strategies.

  5. Value of dipyridamole stress 201Tl myocardial SPECT in detecting dysfunction of coronary microcirculation

    International Nuclear Information System (INIS)

    Lou Ying; Jiang Jinqi; Xie Wenhui; Yuan Fang; Wang Tong; Yang Yiqing

    2012-01-01

    Objective: To evaluate the value of dipyridamole stress 201 Tl myocardial SPECT in detecting dysfunction of coronary microcirculation. Methods: Forty-eight patients diagnosed with cardiac syndrome X underwent dipyridamole stress 201 Tl myocardial SPECT. Dipyridamole (0.56 mg/kg) was intravenously injected over 4 min followed by 201 Tl (111 MBq) injection at 2 min after dipyridamole administration. Image was acquired at 10 min and 240 min post-injection and co-analyzed by over two experienced doctors in nuclear medicine after three-dimensional reconstruction. The patients with 'reverse redistribution' underwent repeated dipyridamole stress 201 Tl SPECT after medical therapy for 2 weeks. The clinical symptoms and results of the treadmill exercise test pre-and post-therapy were compared. Results: Forty two patients (42/48, 87.50%) showed segmental defects: 'reverse redistribution' on delayed (240 min) 201 Tl images. After medical treatment, 36 cases of the 42 'reverse redistribution' patients had improvement in both clinical symptoms and treadmill exercise test. Post-treatment 201 Tl imaging showed improvement in 45/49 (91.84%) defect segments. Six of the 42 patients had no improvement in clinical symptoms and/or treadmill exercise test. Post-treatment 201 Tl imaging showed no improvement in all the 7 defect segments on the first scan. Conclusion: Dipyridamole stress 201 Tl myocardial SPECT may be valuable in evaluation of impaired coronary microcirculation associated with cardiac syndrome X. (authors)

  6. Congenital Absence of Left Circumflex Artery Detected by Computed Tomography Coronary Angiography: A Case Report

    Directory of Open Access Journals (Sweden)

    Keerati Hongsakul

    2012-01-01

    Full Text Available The congenital absence of the left circumflex artery (LCx is a very rare congenital anomaly of coronary arteries, but it is benign. Currently, the best modality for the diagnosis of coronary anomalies is computed tomography coronary angiography (CTCA. We report a case of congenitally absent LCx with an atypical chest pain.

  7. Comparison of electrocardiography and thallium-201 myocardial scintigraphy for the detection of ergonovine-induced coronary artery spasm: angiographic correlation

    International Nuclear Information System (INIS)

    Shanes, J.G.; Pavel, D.; Blend, M.

    1987-01-01

    This study was performed to determine the sensitivity of thallium imaging vs ECG monitoring for detecting coronary artery spasm noninvasively following intravenous ergonovine administration as compared to simultaneous coronary angiography. Thirty-two patients with insignificant coronary artery disease and chest pain underwent 12-lead ECG monitoring, thallium imaging, and coronary arteriography following the administration of 0.05, 0.1, 0.2, and 0.3 mg of ergonovine given 5 minutes apart or until chest pain occurred. One minute following the last dose of ergonovine, 2.5 mCi of thallium-201 was injected intravenously, and a final ECG was recorded and repeat coronary arteriography performed. Within 10 minutes following the injection of thallium, imaging was performed in the 40-degree and 70-degree left anterior oblique and anterior projections. The ECG, thallium study, and coronary arteriogram were read blindly and results were compared. The ECG, angiogram, and thallium study were read as positive if the following occurred, respectively: greater than or equal to 1 mm ST segment elevation, depression, or T wave reversal; greater than 50% vessel narrowing,; and reversible perfusion defect. Five patients were excluded from analysis because of either catheter-induced spasm, suboptimal thallium studies, or protocol violations. Of the 27 patients included for analysis, six had chest pain, five had a positive angiogram, five had a positive thallium study, and one had a positive ECG. The sensitivity of thallium vs ECG monitoring was 80% vs 25%, and the accuracy was 92% vs 80%. We conclude that thallium imaging greatly increases the noninvasive detection of ergonovine-induced coronary spasm as compared with the ECG with no loss of accuracy

  8. Comparison of stress-rest and rest-stress one day myocardial perfusion scintigraphies in detecting coronary artery diseases

    International Nuclear Information System (INIS)

    Bom, Hee Seung; Min, Jung Jun; Song, Ho Cheon; Kim, Ji Yeul

    1997-01-01

    It has been shown that both rest and stress myocardial perfusion imaging with technetium agents can be performed on the same day using two different doses injected within few hours. The purpose of this study was to compare the two protocols (stress-rest and rest-stress) in detecting coronary artery diseases. One hundred and sixty patients (101 males, 59 females, mean age 57±9 years) and 120 patients (79 males, 41 females, mean age 59±10 years) underwent stress-rest myocardial perfusion SPECT and rest-stress myocardial perfusion SPECT, respectively. All of them underwent both myocardial perfusion SPECT and coronary angiography within 1 month. A coronary stenosis was considered significant when it compromised the luminal diameter by ≥50%. The chi square test was used to compare differences in sensitivity, specificity and accuracy between the two groups. The overall sensitivity, specificity and accuracy of stress-rest protocol were 99%, 35% and 68%, respectively. Those of rest-stress protocol were 96%, 47% and 78%, respectively. There was no difference between the two protocols in identifying individual diseased coronary artery branches. Therefore, one day stress-rest and rest-stress myocardial SPECT using 99m Tc agents were comparable and were very sensitive tests in detecting coronary artery diseases

  9. Optical Coherence Tomography Analysis of Attenuated Plaques Detected by Intravascular Ultrasound in Patients with Acute Coronary Syndromes

    Directory of Open Access Journals (Sweden)

    Takashi Kubo

    2011-01-01

    Full Text Available Background. Recent intravascular ultrasound (IVUS studies have demonstrated that hypoechoic plaque with deep ultrasound attenuation despite absence of bright calcium is common in acute coronary syndrome. Such “attenuated plaque” may be an IVUS characteristic of unstable lesion. Methods. We used optical coherence tomography (OCT in 104 patients with unstable angina to compare lesion characteristics between IVUS-detected attenuated plaque and nonattenuated plaque. Results. IVUS-detected attenuated plaque was observed in 41 (39% patients. OCT-detected lipidic plaque (88% versus 49%, <0.001, thin-cap fibroatheroma (48% versus 16%, <0.001, plaque rupture (44% versus 11%, <0.001, and intracoronary thrombus (54% versus 17%, <0.001 were more often seen in IVUS-detected attenuated plaques compared with nonattenuated plaques. Conclusions. IVUS-detected attenuated plaque has many characteristics of unstable coronary lesion. The presence of attended plaque might be an important marker of lesion instability.

  10. Can Stress Echocardiography Compete with Perfusion Scintigraphy in the Detection of Coronary Artery Disease and Cardiac Risk Assessment?

    NARCIS (Netherlands)

    M.L. Geleijnse (Marcel); A. Elhendy (Abdou)

    2000-01-01

    textabstractAims: The aim of this review was to define the place of stress echocardiography in the context of perfusion scintigraphy for the detection of coronary artery disease (CAD) and the assessment of cardiac risk. Stress echocardiography has the benefits of widespread availability, relatively

  11. Characteristic detected on computed tomography angiography predict coronary artery plaque progression in non-culprit lesions

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Ya Hang; Zhou, Jia Zhou; Zhou, Ying; Yang, Xiaobo; Yang, Jun Jie; Chen, Yun Dai [Dept. of Cardiology, Chinese PLA General Hospital, Beijing (China)

    2017-06-15

    This study sought to determine whether variables detected on coronary computed tomography angiography (CCTA) would predict plaque progression in non-culprit lesions (NCL). In this single-center trial, we analyzed 103 consecutive patients who were undergoing CCTA and percutaneous coronary intervention (PCI) for culprit lesions. Follow-up CCTA was scheduled 12 months after the PCI, and all patients were followed for 3 years after their second CCTA examination. High-risk plaque features and epicardial adipose tissue (EAT) volume were assessed by CCTA. Each NCL stenosis grade was compared visually between two CCTA scans to detect plaque progression, and patients were stratified into two groups based on this. Logistic regression analysis was used to evaluate the factors that were independently associated with plaque progression in NCLs. Time-to-event curves were compared using the log-rank statistic. Overall, 34 of 103 patients exhibited NCL plaque progression (33%). Logistic regression analyses showed that the NCL progression was associated with a history of ST-elevated myocardial infarction (odds ratio [OR] = 5.855, 95% confidence interval [CI] = 1.391–24.635, p = 0.016), follow-up low-density lipoprotein cholesterol level (OR = 6.832, 95% CI = 2.103–22.200, p = 0.001), baseline low-attenuation plaque (OR = 7.311, 95% CI = 1.242–43.028, p = 0.028) and EAT (OR = 1.015, 95% CI = 1.000–1.029, p = 0.044). Following the second CCTA examination, major adverse cardiac events (MACEs) were observed in 12 patients, and NCL plaque progression was significantly associated with future MACEs (log rank p = 0.006). Noninvasive assessment of NCLs by CCTA has potential prognostic value.

  12. Sensitivity and accuracy of thallium-201 myocardial scintigraphy in the detection of coronary artery and myocardial disease

    International Nuclear Information System (INIS)

    Loesse, B.; Kroenert, H.; Rafflenbeul, D.; Feinendegen, L.E.; Loogen, F.; Duesseldorf Univ.

    1979-01-01

    169 patients (154 men, 15 women, mean age 49.5 years, range 27 to 64 years) were studied by means of 201-Thallium myocardial scintigraphy (201-Tl) and coronary angiography. According to the coronarangiogram, 130 patients had coronary artery disease (CAD): 53 a 1-vessel CAD, 29 a 2-vessel CAD, 48 a 3-vessel CAD. 39 patients had normal or less than 50% stenosed coronary arteries, but only 13 of these patients had also a normal ventriculogram, whereas 26 had an abnormal ventriculogram with local hypo-, a- or dyskinesia, diffuse hypokinesia, dilatation, or marked hypertrophy. The ramus interventicularis anterior (RIVA) was involved (stenosis of more than 50%) in 117 cases, the ramus circumflexus (R. circ.) in 70 cases, and the right coronary artery (RCA) in 67 cases. 201-Tl was abnormal in 98% of all 130 patients with CAD, in 100% of 93 patients with prior infarction, and in 95% of 37 patients without prior infarction. The sensitivity of the rest and/or exercise ECG in the same patients was only 79%, 88% and 57%, respectively. 201-Tl was abnormal in all 26 patients with a pathologic ventriculogram in spite of normal coronary arteries. 201-Tl and ECG were normal in only 9 of the 13 patients (=69%) with normal coronary arteries and normal ventriculogram. Myocardial biopsy, however, performed in 2 of the other 4 patients disclosed in part severe degenerative changes which can possibly explain the abnormal findings of 201-Tl and ECG. Significantly, i.e. more than 50% stenosed RIVA was correctly detected by 201-Tl in 98%, R. circ. in 71%, and RCA in 91% of the cases. The specificity of 201-Tl was limited by the great number of patients with a pathologic ventriculogram combined with normal coronary arteries. (orig.) [de

  13. Accuracy of automated software-guided detection of significant coronary artery stenosis by CT angiography: comparison with invasive catheterisation

    International Nuclear Information System (INIS)

    Anders, Katharina; Uder, Michael; Achenbach, Stephan; Petit, Isabel; Daniel, Werner G.; Pflederer, Tobias

    2013-01-01

    True automated detection of coronary artery stenoses might be useful whenever expert evaluation is not available, or as a ''second reader'' to enhance diagnostic confidence. We evaluated the accuracy of a PC-based stenosis detection tool alone and combined with expert interpretation. One hundred coronary CT angiography datasets were evaluated with the automated software alone, by manual interpretation (axial images, multiplanar reformations and maximum intensity projections in free double-oblique planes), and by expert interpretation aware of the automated findings. Stenoses ≥ 50 % were noted per-vessel and per-patient, and compared with invasive angiography. Automated post-processing was successful in 90 % of patients (88 % of vessels). When excluding uninterpretable datasets, per-patient sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 89 %, 79 %, 74 % and 92 % (per-vessel: 82 %, 85 %, 48 % and 96 %). All 100 datasets were evaluable by expert interpretation. Per-patient sensitivity, specificity, PPV and NPV were 95 %, 95 %, 93 % and 97 % (per-vessel: 89 %,98 %, 88 % and 98 %). Knowing the results of automated interpretation did not improve the performance of expert readers. Automated off-line post-processing of coronary CT angiography shows adequate sensitivity, but relatively low specificity in coronary stenosis detection. It does not increase accuracy of expert interpretation. Failure of post-processing in 10 % of all patients necessitates additional manual image work-up. (orig.)

  14. Incremental value of contrast myocardial perfusion to detect intermediate versus severe coronary artery stenosis during stress-echocardiography

    Directory of Open Access Journals (Sweden)

    Ugo Fabrizio

    2010-05-01

    Full Text Available Abstract Background We aimed to compare the incremental value of contrast myocardial perfusion imaging (MPI for the detection of intermediate versus severe coronary artery stenosis during dipyridamole-atropine echocardiography (DASE. Wall motion (WM assessment during stress-echocardiography demonstrates suboptimal sensitivity to detect coronary artery disease (CAD, particularly in patients with isolated intermediate (50%-70% coronary stenosis. Methods We performed DASE with MPI in 150 patients with a suspected chest pain syndrome who were given clinical indication to coronary angiography. Results and discussion When CAD was defined as the presence of a ≥50% stenosis, the addition of MPI increased sensitivity (+30% and decreased specificity (-14%, with a final increase in total diagnostic accuracy (+16%, p Conclusions The addition of MPI on top of WM analysis during DASE increases the diagnostic sensitivity to detect obstructive CAD, whatever its definition (≥50% or > 70% stenosis, but it is mainly driven by the sensitivity increase in the intermediate group (50%-70% stenosis. The total diagnostic accuracy increased only when defining CAD as ≥50% stenosis, since in patients with severe stenosis (> 70% the decrease in specificity is not counterbalanced by the minor sensitivity increase.

  15. Effect of CT digital image compression on detection of coronary artery calcification

    International Nuclear Information System (INIS)

    Zheng, L.M.; Sone, S.; Itani, Y.; Wang, Q.; Hanamura, K.; Asakura, K.; Li, F.; Yang, Z.G.; Wang, J.C.; Funasaka, T.

    2000-01-01

    Purpose: To test the effect of digital compression of CT images on the detection of small linear or spotted high attenuation lesions such as coronary artery calcification (CAC). Material and methods: Fifty cases with and 50 without CAC were randomly selected from a population that had undergone spiral CT of the thorax for screening lung cancer. CT image data were compressed using JPEG (Joint Photographic Experts Group) or wavelet algorithms at ratios of 10:1, 20:1 or 40:1. Five radiologists reviewed the uncompressed and compressed images on a cathode-ray-tube. Observer performance was evaluated with receiver operating characteristic analysis. Results: CT images compressed at a ratio as high as 20:1 were acceptable for primary diagnosis of CAC. There was no significant difference in the detection accuracy for CAC between JPEG and wavelet algorithms at the compression ratios up to 20:1. CT images were more vulnerable to image blurring on the wavelet compression at relatively lower ratios, and 'blocking' artifacts occurred on the JPEG compression at relatively higher ratios. Conclusion: JPEG and wavelet algorithms allow compression of CT images without compromising their diagnostic value at ratios up to 20:1 in detecting small linear or spotted high attenuation lesions such as CAC, and there was no difference between the two algorithms in diagnostic accuracy

  16. Adenosine stress cardiovascular magnetic resonance with variable-density spiral pulse sequences accurately detects coronary artery disease: initial clinical evaluation.

    Science.gov (United States)

    Salerno, Michael; Taylor, Angela; Yang, Yang; Kuruvilla, Sujith; Ragosta, Michael; Meyer, Craig H; Kramer, Christopher M

    2014-07-01

    Adenosine stress cardiovascular magnetic resonance perfusion imaging can be limited by motion-induced dark-rim artifacts, which may be mistaken for true perfusion abnormalities. A high-resolution variable-density spiral pulse sequence with a novel density compensation strategy has been shown to reduce dark-rim artifacts in first-pass perfusion imaging. We aimed to assess the clinical performance of adenosine stress cardiovascular magnetic resonance using this new perfusion sequence to detect obstructive coronary artery disease. Cardiovascular magnetic resonance perfusion imaging was performed during adenosine stress (140 μg/kg per minute) and at rest on a Siemens 1.5-T Avanto scanner in 41 subjects with chest pain scheduled for coronary angiography. Perfusion images were acquired during injection of 0.1 mmol/kg Gadolinium-diethylenetriaminepentacetate at 3 short-axis locations using a saturation recovery interleaved variable-density spiral pulse sequence. Significant stenosis was defined as >50% by quantitative coronary angiography. Two blinded reviewers evaluated the perfusion images for the presence of adenosine-induced perfusion abnormalities and assessed image quality using a 5-point scale (1 [poor] to 5 [excellent]). The prevalence of obstructive coronary artery disease by quantitative coronary angiography was 68%. The average sensitivity, specificity, and accuracy were 89%, 85%, and 88%, respectively, with a positive predictive value and negative predictive value of 93% and 79%, respectively. The average image quality score was 4.4±0.7, with only 1 study with more than mild dark-rim artifacts. There was good inter-reader reliability with a κ statistic of 0.67. Spiral adenosine stress cardiovascular magnetic resonance results in high diagnostic accuracy for the detection of obstructive coronary artery disease with excellent image quality and minimal dark-rim artifacts. © 2014 American Heart Association, Inc.

  17. Diagnostic value of stress-rest myocardial perfusion imaging in detection of coronary disease in elderly patients

    International Nuclear Information System (INIS)

    Han Pingping; Tian Yueqin; Fang Wei; Shen Rui; Yang Minfu; Wei Hongxing; Guo Xinhua; He Zuoxiang

    2009-01-01

    Objective: Coronary artery disease is one of the most common causes of death in elderly people. Yet, definite diagnosis is a dilemma due to the variety of symptoms and signs. The aim of this study was to evaluate the diagnostic value of nuclear stress-rest myocardial perfusion imaging(MPI) in detection of coronary disease in the elderly. Methods: Two hundred and five elderly subjects (≥60 years old, average of 67 ± 5) who were suspected to have coronary disease, underwent both stress-rest myocardial perfusion imaging (185 with exercise stress and 20 with adenosine stress) and coronary angiography (CAG). All had no pereutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG). Coronary angiography was used as a 'golden standard' to evaluate the sensitivity, specificity and accuracy of the stress-rest myocardial perfusion imaging. χ 2 -test was used in data analysis with SPSS 15.0. Results: Among 205 patients. there were 57 patients with an abnormal CAG result and 148 patients with a normal result. Of the 57 patients, there were 30 one-, 19 two-, and 8 three-vessel stenosis. Fifteen were mild-, 17 were moderate-, 17 were severe stenosis, and 8 were totally occluded.About 63% (36/57) had positive stress-rest MPI. Of the 148 subjects who had a normal CAG, 135 had negative MPL. The sensitivity.specificity and accuracy of stress MPI were 63% (36/57), 91% (135/148) and 83% (171/205) in patient level.respectively. The di-agnostic sensitivities of stress-rest MPI for detection of one-, two-, and three-vessel stenosis were 57%(17/30), 58% (11/19) and 8/8, respectively. All 185 patients who underwent exemise stress MPI were divided into 2 groups according to whether the patients reached the target heart rate or not at the peak of the test. And 53 patients (29%) were group 1 (reached the target heart rate)and 132 patients (71%) were group 2 (did not reach the target heart rate). The sensitivity of group 1 wag higher than that of group 2, but with no

  18. Association of apolipoprotein b/apolipoprotein A1 ratio and coronary artery stenosis and plaques detected by multi-detector computed tomography in healthy population.

    Science.gov (United States)

    Jung, Chang Hee; Hwang, Jenie Yoonoo; Shin, Mi Seon; Yu, Ji Hee; Kim, Eun Hee; Bae, Sung Jin; Yang, Dong Hyun; Kang, Joon-Won; Park, Joong-Yeol; Kim, Hong-Kyu; Lee, Woo Je

    2013-05-01

    Despite the noninvasiveness and accuracy of multidetector computed tomography (MDCT), its use as a routine screening tool for occult coronary atherosclerosis is unclear. We investigated whether the ratio of apolipoprotein B (apoB) to apolipoprotein A1 (apoA1), an indicator of the balance between atherogenic and atheroprotective cholesterol transport could predict occult coronary atherosclerosis detected by MDCT. We collected the data of 1,401 subjects (877 men and 524 women) who participated in a routine health screening examination of Asan Medical Center. Significant coronary artery stenosis defined as > 50% stenosis was detected in 114 subjects (8.1%). An increase in apoB/A1 quartiles was associated with increased percentages of subjects with significant coronary stenosis and noncalcified plaques (NCAP). After adjustment for confounding variables, each 0.1 increase in serum apoB/A1 was significantly associated with increased odds ratios (ORs) for coronary stenosis and NCAP of 1.23 and 1.18, respectively. The optimal apoB/A1 ratio cut off value for MDCT detection of significant coronary stenosis was 0.58, which had a sensitivity of 70.2% and a specificity of 48.2% (area under the curve, 0.61; 95% CI, 0.58-0.63, P < 0.001). Our results indicate that apoB/A1 ratio is a good indicator of occult coronary atherosclerosis detected by coronary MDCT.

  19. Non-invasive detection of aortic and coronary atherosclerosis in homozygous familial hypercholesterolemia by 64 slice multi-detector row computed tomography angiography

    Science.gov (United States)

    Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row ...

  20. Additional diagnostic value of systolic dysfunction induced by dipyridamole stress cardiac magnetic resonance used in detecting coronary artery disease.

    Science.gov (United States)

    Husser, Oliver; Bodí, Vicente; Sanchís, Juan; Mainar, Luis; Núñez, Julio; López-Lereu, María P; Monmeneu, José V; Ruiz, Vicente; Rumiz, Eva; Moratal, David; Chorro, Francisco J; Llácer, Angel

    2009-04-01

    Dipyridamole stress perfusion cardiovascular magnetic resonance (CMR) is used to detect coronary artery disease (CAD). However, few data are available on the diagnostic value of the systolic dysfunction induced by dipyridamole. This study investigated whether the induction of systolic dysfunction supplements the diagnostic information provided by perfusion imaging in the detection of CAD. Overall, 166 patients underwent dipyridamole CMR and quantitative coronary angiography, with CAD being defined as a stenosis > or =70%. Systolic dysfunction at rest, systolic dysfunction with dipyridamole, induced systolic dysfunction, and stress first-pass perfussion deficit (PD) and delayed enhancement were quantified. In the multivariate analysis, PD (hazard ratio [HR]=1.6; 95% confidence interval [CI], 1.33-1.91;Pstatistic for predicting CAD (0.81 vs. 0.87; P=.02). Combining induced systolic dysfunction with perfusion imaging increases the diagnostic accuracy of detecting CAD and enables patients with severe ischemia and a high probability of CAD to be identified.

  1. Comparison of exercise radionuclide angiography with thallium SPECT imaging for detection of significant narrowing of the left circumflex coronary artery

    International Nuclear Information System (INIS)

    Dilsizian, V.; Perrone-Filardi, P.; Cannon, R.O. III; Freedman, N.M.; Bacharach, S.L.; Bonow, R.O.

    1991-01-01

    Although quantitation of exercise thallium tomograms has enhanced the noninvasive diagnosis and localization of coronary artery disease, the detection of stenosis of the left circumflex coronary artery remains suboptimal. Because posterolateral regional wall motion during exercise is well assessed by radionuclide angiography, this study determined whether regional dysfunction of the posterolateral wall during exercise radionuclide angiography is more sensitive in identifying left circumflex disease than thallium perfusion abnormalities assessed by single-photon emission computed tomography (SPECT). One hundred ten consecutive patients with CAD were studied, of whom 70 had a significant stenosis of the left circumflex coronary artery or a major obtuse marginal branch. Both regional function and segmental thallium activity of the posterolateral wall were assessed using visual and quantitative analysis. Left ventricular regional function was assessed objectively by dividing the left ventricular region of interest into 20 sectors; the 8 sectors corresponding to the posterolateral free wall were used to assess function in the left circumflex artery distribution. Similarly, using circumferential profile analysis of short-axis thallium tomograms, left ventricular myocardial activity was subdivided into 64 sectors; the 16 sectors corresponding to the posterolateral region were used to assess thallium perfusion abnormalities in the left circumflex artery territory. Qualitative posterolateral wall motion analysis detected 76% of patients with left circumflex coronary artery stenosis, with a specificity of 83%, compared with only 44% by qualitative thallium tomography (p less than 0.001) and a specificity of 92%

  2. Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT

    International Nuclear Information System (INIS)

    Ooijen, Peter M.A. van; Dorgelo, Joost; Oudkerk, Matthijs; Zijlstra, Felix

    2004-01-01

    Early identification and evaluation of relatively frequent anomalous coronary anatomy is quite relevant because of the occurrence of sudden cardiac death or related symptoms of myocardial ischemia. Selective coronary angiography (CAG) is invasive, expensive and cannot always provide the required information adequately. Recently, non-invasive imaging techniques such as magnetic resonance imaging and multidetector-row computed tomography (MDCT) have been shown to provide a good anatomical view of the coronary artery tree. This study aims to demonstrate the value of 16-MDCT for evaluation of anomalous coronary anatomy. In 13 patients scanned using 16-MDCT, six different coronary anomalies were diagnosed [two absent left main, one single vessel left coronary artery (LCA), three LCA originating from the right (two with interarterial course), six right coronary artery originating from the left, one double left anterior descending (LAD)]. Mean diagnostic quality, recorded by two observers using a 5-point scale (1= non-diagnostic to 5= excellent diagnostic quality), resulted in a mean score of 3.73 (SD 1.19) without any non-diagnostic result. MDCT offers an accurate diagnostic modality to visualize the origin and course of anomalous coronary arteries by a three-dimensional display of anatomy. Shortcomings in CAG can be overcome by the use of contrast-enhanced MDCT. (orig.)

  3. Importance of adequate exercise in the detection of coronary heart disease by radionuclide ventriculography

    International Nuclear Information System (INIS)

    Brady, T.J.; Thrall, J.H.; Lo, K.; Pitt, B.

    1980-01-01

    Rest and exercise radionuclide ventriculograms were obtained on 77 symptomatic patients without prior documented coronary artery disease (CAD). Coronary artery disease was present by angiograms in 48. Radionuclide ventriculography (RNV) was abnormal in 41 patients (overall sensitivity 85%). In 29 patients with normal coronary arteries, RNV was normal in 24 (specificity 83%). To determine if the exercise level affects sensitivity, the studies were graded for adequacy of exercise. It was considered adequate if patients developed (a) chest pain, or (b) ST segment depression of at least 1 mm, or (c) if they achieved a pressure rate product greater than 250. Among the 48 patients with coronary artery disease, 35 achieved adequate exercise. Thirty-three had an abnormal RNV (sensitivity 94%). In 13 patients who failed to achieve adequate exercise, RNV was abnormal in eight (sensitivity of only 62%). Some patients with coronary artery disease may have a normal ventricular response at inadequate levels of stress

  4. Detection of coronary artery disease with exercise 99Tcm-MIBI SPECT in patients with atrial fibrillation

    International Nuclear Information System (INIS)

    Yang Minfu; Guo Xinhua; He Zuoxiang; Tou Kefei; Yang Yuejin

    2007-01-01

    Objective: To investigate the ability of exercise myocardial perfusion imaging (MPI) for detecting coronary artery disease (CAD) in patients with atrial fibrillation (AF). Methods: Fifty-eight consecutive patients with AF during symptom-limited exercise 99 Tc m -methoxyisobutylisonitrile (MIBI) SPECT imaging were retrospectively analyzed. All patients underwent coronary angiography within an interval of 90 d. Results: The overall diagnostic sensitivity, specificity and accuracy of exercise 99 Tc m -MIBI SPECT were 60% (9/15), 88% (38/43) and 81% (47/58), respectively. Among patients without valvular disease, the diagnostic sensitivity and specificity were 60% (9/15) and 96% (22/23). The diagnostic accuracy was 80% (16/20) in patients with valvular heart disease. Conclusion: In patients with AF during exercise test, exercise MPI has a moderate sensitivity and an excellent specificity in detection of CAD to those without valvular disease, and has a high diagnostic accuracy in patients with valvular heart disease. (authors)

  5. Magnetic resonance pharmacological stress for detecting coronary disease. Comparison with echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Baer, F.M.; Crnac, J.; Jochims, M.; Schneider, C.; Erdmann, E. [Clinic III of Internal Medicine, Univ. of Cologne (Germany); Schmidt, M.; Theissen, P.; Schicha, H. [Clinic und Ambulant Clinic of Nuclear Medicine, Univ. of Cologne (Germany)

    2000-06-01

    Stress testing is the cornerstone in the diagnosis of patients with suspected coronary artery disease (CAD). Although exercise ECG remains the primary approach for the detection of ischemia in patients with chest pain syndromes, its sensitivity and specificity is limited and exercise ECG does not provide detailed information about the localisation and extent of CAD. Stress echocardiography has been used for the detection of ischemia for more than a decade and has become an increasingly popular noninvasive method for the detection of CAD. In experienced hands wall motion analysis based on stress echocardiography has proved to be as sensitive and specific for the detection of myocardial ischemia as scintigraphic techniques. Recent technical improvements, namely the availability of ultrafast imaging sequences with a significant reduction of imaging time have initiated several studies which examined the combination of pharmacological stress and magnetic resonance imaging (MRI) for the detection of suspected CAD. The most well developed stress-MRI technique is wall motion imaging during dobutamine stress. This technique is analogous to stress echocardiography, but MRI has the inherent advantages of better resolution, higher reproducibility and true long and short axis imaging with contiguous parallel slices. However, the clinical impact of MRI for the diagnosis of CAD is still low. Further technical developments including real time imaging and a reliable automated quantitative analysis of left ventricular function are required before stress-MRI becomes a serious challenge to stressechocardiography in the clinical arena. Currently, only a few MRI facilities and physicians are dedicated to pharmacological stress testing with MRI and the future clinical impact of this promising technique will depend on its potential to provide information beyond myocardial function including perfusion, metabolism and coronary anatomy in form of a ''one-stop''-shop for

  6. Mammographic detection of breast arterial calcification as an independent predictor of coronary atherosclerotic disease in a single ethnic cohort of African American women

    NARCIS (Netherlands)

    Newallo, Domnique; Meinel, Felix G.; Schoepf, U. Joseph; Baumann, Stefan; De Cecco, Carlo N.; Leddy, Rebecca J.; Vliegenthart, Rozemarijn; Moellmann, Helge; Hamm, Christian W.; Morris, Pamela B.; Renker, Matthias

    Objective: Accumulating data on predominantly Caucasian women suggests an association between breast arterial calcification (BAC) and coronary artery disease (CAD). We sought to comprehensively examine the correlation between mammographic BAC and CAD endpoints detected by cardiac computed tomography

  7. Detection of angina-related coronary artery in patients with unstable angina pectoris by using 123I-BMIPP myocardial scintigraphy

    International Nuclear Information System (INIS)

    Oka, Toshiaki; Inoue, Seiji; Asano, Ryuta; Handa, Atsushi; Iguchi, Nobuo; Sumiyoshi, Tetsuya; Hosoda, Saichi; Kobayashi, Hideki; Kusakabe, Kiyoko.

    1996-01-01

    To evaluate the diagnostic accuracy of detection of angina-related coronary arteries in patients with unstable angina pectoris. Twenty patients with unstable angina pectoris underwent 123 I-BMIPP scintigraphy at rest. A mean duration from last anginal attack to 123 I-BMIPP scintigraphy was 4.8±3.2 days. Seventeen of 20 angina-related coronary territories were detected by reduced 123 -BMIPP uptake. The sensitivity and specificity for detection of angina-related coronary arteries were 85% and 95%, respectively. The decrease in myocardial uptake of 123 I-BMIPP agreed with the decrease in regional wall motion by using ultrasonic echocardiography. 123 I-BMIPP scintigraphy may be useful for detection of angina-related coronary artery in a routine clinical examination in patients with unstable angina pectoris. (author)

  8. Stress thallium-201 myocardial scintigraphy for the detection of individual coronary arterial lesions in patients with and without previous myocardial infarction

    International Nuclear Information System (INIS)

    Rigo, P.; Bailey, I.K.; Griffith, L.S.; Pitt, B.; Wagner, H.N. Jr.; Becker, L.C.

    1981-01-01

    The value of stress thallium-201 scintigraphy for detecting individual coronary arterial stenoses was analyzed in 141 patients with angiographically proved coronary artery disease, 101 with and 40 without a previous myocardial infarction. In patients without infarction, the sensitivity for detecting greater than 50 percent narrowing in the left anterior descending, the right and the left circumflex coronary artery was 66, 53 and 24 percent, respectively. In those with a previous infarction, the sensitivity for demonstrating disease in the artery corresponding to the site of infarction was 100 percent for the left anterior descending, 79 percent for the right and 63 percent for the left circumflex coronary artery. In patients with a prior anterior infarction, concomitant right or left circumflex coronary arterial lesions were detected in only 1 of 12 cases, whereas in those with previous inferior or inferolateral infarction, the sensitivity for left anterior descending coronary artery disease was 69 percent. Because of the reasonably high sensitivity for detecting left anterior descending arterial disease, irrespective of the presence and location of previous infarction, myocardial scintigraphy was useful in identifying multivessel disease in patients with a previous inferior infarction. However, because of its relative insensitivity for right or left circumflex coronary artery disease, scintigraphy proved to be a poor predictor of multivessel disease in patients with a prior anterior infarction and in patients without previous myocardial infarction

  9. Framework for detection and localization of coronary non-calcified plaques in cardiac CTA using mean radial profiles.

    Science.gov (United States)

    Jawaid, Muhammad Moazzam; Riaz, Atif; Rajani, Ronak; Reyes-Aldasoro, Constantino Carlos; Slabaugh, Greg

    2017-10-01

    The high mortality rate associated with coronary heart disease (CHD) has driven intensive research in cardiac imaging and image analysis. The advent of computed tomography angiography (CTA) has turned non-invasive diagnosis of cardiovascular anomalies into reality as calcified coronary plaques can be easily identified due to their high intensity values. However, the detection of non-calcified plaques in CTA is still a challenging problem because of lower intensity values, which are often similar to the nearby blood and muscle tissues. In this work, we propose the use of mean radial profiles for the detection of non-calcified plaques in CTA imagery. Accordingly, we computed radial profiles by averaging the image intensity in concentric rings around the vessel centreline in a first stage. In the subsequent stage, an SVM classifier is applied to identify the abnormal coronary segments. For occluded segments, we further propose a derivative-based method to localize the position and length of the plaque inside the segment. A total of 32 CTA volumes were analysed and a detection accuracy of 88.4% with respect to the manual expert was achieved. The plaque localization accuracy was computed using the Dice similarity coefficient and a mean of 83.2% was achieved. The consistent performance for multi-vendor, multi-institution data demonstrates the reproducibility of our method across different CTA datasets with a good agreement with manual expert annotations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. The relationship between coronary artery calcification detected by non-gated multi-detector CT in patients with suspected ischemic heart disease and myocardial ischemia detected by thallium exercise stress testing

    International Nuclear Information System (INIS)

    Nishida, Chikako; Okajima, Kaoru; Yamamoto, Takashi; Hattori, Ryuichi; Kudo, Takashi; Nishimura, Yasumasa

    2005-01-01

    The objective of this study was to examine whether we could predict myocardial ischemia when coronary artery calcification is detected by non-gated multidetector CT in patients with suspected ischemic heart disease. Eighty-three patients suspected of having ischemic heart disease (55 men, 28 women; age range 36-83 years; mean age 68 years) underwent multidetector CT and Tl-201 single photon emission computed tomography. Prediction of myocardial ischemia by coronary arterial calcification detected on CT was evaluated by comparing the coronary artery territories that showed calcification with the area of myocardial ischemia determined by SPECT. The sensitivity, specificity, positive predictive value, and negative predictive value of multidetector CT for predicting myocardial ischemia were calculated. Coronary angiography was also examined and compared with multidetector CT. Risk factors, including hypertension, smoking, hyperlipidemia, diabetes, and family history, were compared for evidence of coronary artery calcification detected by multidetector CT and myocardial ischemia detected by thallium nuclear scans. For analysis by patients, the sensitivity, specificity, positive predictive value, and negative predictive value of coronary artery calcification for myocardial ischemia detection were 65, 63, 56, and 71%, respectively. Similarly, for analysis by coronary arterial territories, those values were 56, 77, 41 and 86%, respectively. Coronary stenosis on CAG was also related to the ischemia determined by SPECT and calcification on multidetector CT. Ischemia was better influenced by risk factors than was coronary arterial calcification. For analysis by coronary arterial territories, the specificity and negative predictive value of coronary arterial calcification seen by multidetector CT are relatively high. (author)

  11. Invasive or non-invasive imaging for detecting high-risk coronary lesions?

    NARCIS (Netherlands)

    K. Patel (Kush); J. Tarkin (Jason); P.W.J.C. Serruys (Patrick); E. Tenekecioglu (Erhan); N. Foin (Nicolas); Y. Zhang (Yaojun); T. Crake (Tom); J. Moon (James); A. Mathur (Anthony); C.V. Bourantas (Christos)

    2017-01-01

    markdownabstract_Introduction:_ Advances in our understanding about atherosclerotic evolution have enabled us to identify specific plaque characteristics that are associated with coronary plaque vulnerability and cardiovascular events. With constant improvements in signal and image processing an

  12. Early detection of restenosis after successful percutaneous transluminal coronary angioplasty by exercise-redistribution Thallium scintigraphy

    NARCIS (Netherlands)

    W. Wijns (William); P.W.J.C. Serruys (Patrick); J.H.C. Reiber (Johan); P.J. de Feyter (Pim); M.J.B.M. van den Brand (Marcel); M.L. Simoons (Maarten); P.G. Hugenholtz (Paul)

    1985-01-01

    textabstractThe value of exercise testing and thallium scintigraphy in predicting recurrence of angina pectoris and restenosis after a primary successful transluminal coronary angioplasty (PTCA) was prospectively evaluated. In 89 patients, a symptom-limited exercise electrocardiogram (ECG) and

  13. Chronic myocardial infarction detection and characterization during coronary artery calcium scoring acquisitions.

    LENUS (Irish Health Repository)

    Rodríguez-Granillo, Gastón A

    2012-01-05

    Hypoenhanced regions on multidetector CT (MDCT) coronary angiography correlate with myocardial hyperperfusion. In addition to a limited capillary density, chronic myocardial infarction (MI) commonly contains a considerable amount of adipose tissue.

  14. Noninvasive detection and assessment of coronary artery disease by dipyridamloe thallium-201 imaging

    International Nuclear Information System (INIS)

    Jiang Maosong

    1988-01-01

    Dipyridamole (DP) thallium-201 perfusion scintigraphy was performed in 73 patients. IV DP (0.56 mg/kg) infused over 4 min. resulted in an increases in mean HR from 74 +- 12 bpm to a peak of 86 +- 12 bpm (p 201 Tl scintigraphy appears highly sensitive for the diagnosis of coronary artery highly sensitive for the diagnosis of coronary artery disease and provides a useful alternative test for patients who are unable to perform maximal exercise

  15. Detection and quantification of coronary calcium from dual energy chest x-rays: Phantom feasibility study.

    Science.gov (United States)

    Zhou, Bo; Wen, Di; Nye, Katelyn; Gilkeson, Robert C; Eck, Brendan; Jordan, David; Wilson, David L

    2017-10-01

    We have demonstrated the ability to identify coronary calcium, a reliable biomarker of coronary artery disease, using nongated, 2-shot, dual energy (DE) chest x-ray imaging. Here we will use digital simulations, backed up by measurements, to characterize DE calcium signals and the role of potential confounds such as beam hardening, x-ray scatter, cardiac motion, and pulmonary artery pulsation. For the DE calcium signal, we will consider quantification, as compared to CT calcium score, and visualization. We created stylized and anatomical digital 3D phantoms including heart, lung, coronary calcium, spine, ribs, pulmonary artery, and adipose. We simulated high and low kVp x-ray acquisitions with x-ray spectra, energy dependent attenuation, scatter, ideal detector, and automatic exposure control (AEC). Phantoms allowed us to vary adipose thickness, cardiac motion, etc. We used specialized dual energy coronary calcium (DECC) processing that includes corrections for scatter and beam hardening. Beam hardening over a wide range of adipose thickness (0-30 cm) reduced the change in intensity of a coronary artery calcification (ΔI CAC ) by calcium signal (ΔI CAC ) in DECC images ±9%. If a simulated pulmonary artery fills with blood between exposures, it can give rise to a residual signal in DECC images, explaining pulmonary artery visibility in some clinical images. Residual misregistration can be mostly compensated by integrating signals in an enlarged region encompassing registration artifacts. DECC calcium score compared favorably to CT mass and volume scores over a number of phantom perturbations. Simulations indicate that proper DECC processing can faithfully recover coronary calcium signals. Beam hardening, errors in scatter estimation, cardiac motion, calcium residual misregistration etc., are all manageable. Simulations are valuable as we continue to optimize DE coronary calcium image processing and quantitative analysis. © 2017 American Association of Physicists

  16. Comparison of multislice computed tomography with intravascular ultrasound for detection and characterization of coronary artery plaques: A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Springer, Ivonne [Department of Radiology, Charite, Medical School, Humboldt-Universitaet zu Berlin (Germany); Dewey, Marc [Department of Radiology, Charite, Medical School, Humboldt-Universitaet zu Berlin (Germany)], E-mail: marc.dewey@charite.de

    2009-08-15

    Purpose: Multislice computed tomography (MSCT) is a novel non-invasive test for detection and analysis of coronary artery plaques. A systematic review was conducted of the literature to compare MSCT with IVUS as the reference standard for assessing coronary artery plaques. Materials and methods: We performed a literature search in the online database MEDLINE, which was accessed at (http://www.pubmed.gov) on 9th April 2008. Results: The search identified 14 studies with 340 patients (mean age 59 {+-} 5 years). The systematic review revealed a sensitivity of MSCT on the lesion level (n = 1779 coronary plaques) on the order of 90% (range from 87 to 92%) in comparison to IVUS. Per-segment analysis (n = 356) yielded a lower sensitivity of 81-86%. In the per-vessel analysis (n = 90), MSCT had a better sensitivity and specificity for the RCA (83-89% and 92-100%) and the LAD (83-87% and 93%) than for the LCX (71-85% and 77-89%), and on the vessel level and the cross-section analysis MSCT was more sensitive for calcified plaques than for non-calcified plaque. It is noteworthy that most studies provide only incomplete data on technical and methodological parameters such as radiation exposure and patient characteristics. Conclusion: MSCT is an accurate and reliable test for detection of coronary artery plaques in comparison to IVUS with limitations in regards to the LCX and non-calcified plaques. Studies published thus far are limited by the sample sizes and methodological quality issues.

  17. Contrast-enhanced magnetic resonance imaging for the detection of ruptured coronary plaques in patients with acute myocardial infarction.

    Directory of Open Access Journals (Sweden)

    Christian H P Jansen

    Full Text Available X-ray coronary angiography (XCA is the current gold standard for the assessment of lumen encroaching coronary stenosis but XCA does not allow for early detection of rupture-prone vulnerable plaques, which are thought to be the precursor lesions of most acute myocardial infarctions (AMI and sudden death. The aim of this study was to investigate the potential of delayed contrast-enhanced magnetic resonance coronary vessel wall imaging (CE-MRCVI for the detection of culprit lesions in the coronary arteries.16 patients (13 male, age 61.9±8.6 years presenting with sub-acute MI underwent CE-MRCVI within 24-72h prior to invasive XCA. CE-MRCVI was performed using a T1-weighted 3D gradient echo inversion recovery sequence (3D IR TFE 40±4 minutes following the administration of 0.2 mmol/kg gadolinium-diethylenetriamine-pentaacetic acid (DTPA on a 3T MRI scanner equipped with a 32-channel cardiac coil.14 patients were found to have culprit lesions (7x LAD, 1xLCX, 6xRCA as identified by XCA. Quantitative CE-MRCVI correctly identified the culprit lesion location with a sensitivity of 79% and excluded culprit lesion formation with a specificity of 99%. The contrast to noise ratio (CNR of culprit lesions (9.7±4.1 significantly exceeded CNR values of segments without culprit lesions (2.9±1.9, p<0.001.CE-MRCVI allows the selective visualization of culprit lesions in patients immediately after myocardial infarction (MI. The pronounced contrast uptake in ruptured plaques may represent a surrogate biomarker of plaque activity and/or vulnerability.

  18. Feasibility of spectral shaping for detection and quantification of coronary calcifications in ultra-low dose CT

    Energy Technology Data Exchange (ETDEWEB)

    Vonder, Marleen; Pelgrim, Gert Jan; Vliegenthart, Rozemarijn [University of Groningen, University Medical Center Groningen, Department of Radiology, Groningen (Netherlands); University of Groningen, University Medical Center Groningen, Center for Medical Imaging North-East Netherlands (CMI-NEN), Groningen (Netherlands); Huijsse, Sevrin E.M.; Greuter, Marcel J.W. [University of Groningen, University Medical Center Groningen, Department of Radiology, Groningen (Netherlands); Meyer, Mathias; Henzler, Thomas [Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim, University Medical Center Mannheim, Heidelberg (Germany); Flohr, Thomas G. [Siemens Healthcare GmbH, Computed Tomography, Forchheim (Germany); Oudkerk, Matthijs [University of Groningen, University Medical Center Groningen, Center for Medical Imaging North-East Netherlands (CMI-NEN), Groningen (Netherlands)

    2017-05-15

    To evaluate detectability and quantification of coronary calcifications for CT with a tin filter for spectral shaping. Phantom inserts with 100 small and 9 large calcifications, and a moving artificial artery with 3 calcifications (speed 0-30 mm/s) were placed in a thorax phantom simulating different patient sizes. The phantom was scanned in high-pitch spiral mode at 100 kVp with tin filter (Sn100 kVp), and at a reference of 120 kVp, with electrocardiographic (ECG) gating. Detectability and quantification of calcifications were analyzed for standard (130 HU) and adapted thresholds. Sn100 kVp yielded lower detectability of calcifications (9 % versus 12 %, p = 0.027) and lower Agatston scores (p < 0.008), irrespective of calcification, patient size and speed. Volume scores of the moving calcifications for Sn100 kVp at speed 10-30 mm/s were lower (p < 0.001), while mass scores were similar (p = 0.131). For Sn100 kVp with adapted threshold of 117 HU, detectability (p = 1.000) and Agatston score (p > 0.206) were similar to 120 kVp. Spectral shaping resulted in median dose reduction of 62.3 % (range 59.0-73.4 %). Coronary calcium scanning with spectral shaping yields lower detectability of calcifications and lower Agatston scores compared to 120 kVp scanning, for which a HU threshold correction should be developed. (orig.)

  19. Clinical evaluation of 99Tcm-MIBI myocardial perfusion imaging for the detection of coronary artery disease in patients with metabolic syndrome

    International Nuclear Information System (INIS)

    Tian Yueqin; Wei Hongxing; Guo Xinhua; Guo Feng; He Zuoxiang

    2008-01-01

    Objective: Metabolic syndrome is a combination of medical disorders that consist of a collection of independent factors at risk of developing coronary artery disease. The purpose of this study was to evaluate the value of 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion imaging for the diagnosis of coronary artery disease in patients with metabolic syndrome. Methods: A total of 251 patients [mean age (59 ± 10) years, 179 men, 72 women] were included in this study. All patients underwent exercise and rest 99 Tc m -MIBI myocardial perfusion imaging and coronary angiography. Results: Of the 163 patients with significant coronary artery stenosis, 116 showed abnormal 99 Tc m -MIBI myocardial perfusion imaging; and among the 88 patients with normal coronary angiography, 82 showed normal myocardial perfusion imaging. The sensitivity, specificity and accuracy of 99 Tc m -MIBI myocardial perfusion imaging for coronary artery disease detection were 71% (116/163), 93% (82/88) and 79% (198/251), respectively. The positive and negative predictive values were 95% (116/122) and 64% (82/129), respectively. Conclusion: 99 Tc m -MIBI myocardial perfusion imaging has important clinical value for detecting coronary artery disease in patients with metabolic syndrome. (authors)

  20. Noninvasive detection of regional myocardial ischemia using rubidium-81 and scintillation camera. Comparison with stress electrocardiography in patients with arteriographically documented coronary stenosis

    International Nuclear Information System (INIS)

    Berman, D.S.; Salel, A.F.; DeNardo, G.L.; Mason, D.T.

    1975-01-01

    The sensitivity of rest and stress myocardial perfusion studies using scintillation camera imaging of intravenously administered rubidium-81 ( 81 Rb) in the detection of myocardial ischemia was compared to that of stress electrocardiography by relating results in 40 patients to the degree of stenosis delineated by coronary arteriography. Of 33 patients with greater than 75 percent stenosis of at least one of the three major coronary vessels (significant stenosis), rest and stress 81 Rb imaging detected ventricular ischemia in 29 (88 percent), whereas simultaneous stress electrocardiography was positive (1 mm or greater horizontal ST-segment depression) in only 19 (58 percent) of the same patients. Five of the 29 patients who developed stress-induced scintigraphic evidence of ischemia did not develop angina or a positive electrocardiogram with stress. In 31 of the 33 patients with significant coronary stenosis, either the stress scintigram or the stress electrocardiogram was positive. In seven patients with less than 50 percent narrowing of a major coronary vessel on coronary arteriography, the stress scintigrams were negative, whereas the stress electrocardiograms were positive in the two of these patients with the syndrome of angina with normal coronary arteriograms. It is concluded that high resolution images of the myocardium can be obtained with 81 Rb using the scintillation camera with special shielding, and that rest and stress 81 Rb scintigraphy appears to provide greater sensitivity and specificity when compared to stress electrocardiography in the noninvasive identification of significant coronary stenosis

  1. Reproducibility of coronary calcification detection with electron-beam computed tomography

    International Nuclear Information System (INIS)

    Hernigou, A.; Challande, P.; Boudeville, J.C.; Sene, V.; Grataloup, C.; Plainfosse, M.

    1996-01-01

    If coronary calcification scores obtained with electron-beam computed tomography (EBT) were proved to be correlated to coronary atherosclerosis, the reproducibility of the technique had to be assessed before being useed for patient follow-up. A total of 150 patients, selected as a result of a cholesterol screening programme, were studied by EBT. Twelve contiguous 3-mm-thick transverse slices beginning on the proximal coronary arteries were obtained through the base of the heart. The amount of calcium was evaluated as the calcified area weighted by a coefficient depending on the density peak level. The value was expressed as a logarithmic scale. Intra-observer, inter-observer and inter-examination reproducibilities were calculated. They were 1.9, 1.3 and 7.2%, respectively. These results were good enough to allow the use of EBT for longitudinal studies. The influence of acquisition and calculation conditions on score computation were also analysed. (orig.)

  2. Estimation of myocardial flow reserve utilizing an ultrafast cardiac SPECT: Comparison with coronary angiography, fractional flow reserve, and the SYNTAX score.

    Science.gov (United States)

    Miyagawa, Masao; Nishiyama, Yoshiko; Uetani, Teruyoshi; Ogimoto, Akiyoshi; Ikeda, Shuntaro; Ishimura, Hayato; Watanabe, Emiri; Tashiro, Rami; Tanabe, Yuki; Kido, Teruhito; Kurata, Akira; Mochizuki, Teruhito

    2017-10-01

    Quantitative assessment of myocardial flow reserve (MFR) by single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is challenging but may facilitate evaluation of multi-vessel coronary artery disease (CAD). We enrolled 153 patients with suspected or known CAD, referred for pharmacological stress MPI. They underwent a 99m Tc-perfusion stress/rest SPECT with an ultrafast cadmium-zinc-telluride (CZT) camera. Dynamic data were acquired and time-activity curves fitted to a 1-tissue compartment analysis with input function. K1 was assigned for stress and rest data. The MFR index (MFRi) was calculated as K1 stress/K1 at-rest. The findings were validated by invasive coronary angiography in 69 consecutive patients. The global MFRi was 1.46 (1.16-1.76), 1.33 (1.12-1.54), and 1.18 (1.01-1.35), for 1-vessel disease (VD), 2-VD, and 3-VD, respectively. In the 3-VD, global MFRi was lower than that in 0-VD (1.63 [1.22-2.04], Pfraction (OR: 61.6 [57.5-66.0]), and global MFRi (OR: 119.6 [111.5-127.7], P=0.002). A cut-off value of 1.3 yielded 93.3% sensitivity and 75.9% specificity for diagnosing 3-VD. Fractional flow reserve positively correlated with regional MFRi (r=0.62, P=0.008), and the SYNTAX score correlated negatively with global MFRi (r=0.567, P=0.0003). We developed and validated a clinically available method for MFR quantification by dynamic 99m Tc-perfusion SPECT utilizing a CZT camera, which improves the detectability of multi-vessel CAD. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Coronary ostial involvement in acute aortic dissection: detection with 64-slice cardiac CT.

    LENUS (Irish Health Repository)

    Ryan, E Ronan

    2012-02-01

    A 41-year-old man collapsed after lifting weights at a gym. Following admission to the emergency department, a 64-slice cardiac computed tomography (CT) revealed a Stanford Type A aortic dissection arising from a previous coarctation repair. Multiphasic reconstructions demonstrated an unstable, highly mobile aortic dissection flap that extended proximally to involve the right coronary artery ostium. Our case is an example of the application of electrocardiogram-gated cardiac CT in directly visualizing involvement of the coronary ostia in acute aortic dissection, which may influence surgical management.

  4. Relationship between the total length of the stents and patients' quality of life after percutaneous coronary intervention.

    Science.gov (United States)

    Liu, Wei; Yang, Xuming; Dong, Pingshuan; Li, Zhijuan

    2015-01-01

    The aim of this study was to examine the relationship between the total length of the stents and the postoperative life quality of patients with multi-vessel coronary artery disease who undergo percutaneous coronary intervention (PCI). Using the short-form health survey (SF-36) items, we analyzed the data on the postoperative life quality of 166 patients with multi-vessel coronary artery disease who underwent percutaneous transluminal coronary intervention in the Department of Cardiology of the First Affiliated Hospital of Henan University of Science and Technology from September 2011 to September 2013. Follow-up was performed 6 months later. All of the dimensionalities, except general health and mental health, showed significantly higher scores after PCI. No significant relationships were observed between the total length of the stents and the postoperative life quality of patients with multi-vessel coronary artery disease who underwent PCI. PCI can effectively improve the postoperative life quality of patients; however, there was no significant relationship between the total length of the stents and postoperative life quality of patients.

  5. Multislice computed tomography: angiographic emulation versus standard assessment for detection of coronary stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Schnapauff, Dirk; Hamm, Bernd; Dewey, Marc [Humboldt-Universitaet zu Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin, Chariteplatz 1, P.O. Box 10098, Berlin (Germany); Duebel, Hans-Peter; Baumann, Gert [Charite - Universitaetsmedizin Berlin, Department of Cardiology, Berlin (Germany); Scholze, Juergen [Charite - Universitaetsmedizin Berlin, Charite Outpatient Centre, Berlin (Germany)

    2007-07-15

    The present study investigated angiographic emulation of multislice computed tomography (MSCT) (catheter-like visualization) as an alternative approach of analyzing and visualizing findings in comparison with standard assessment. Thirty patients (120 coronary arteries) were randomly selected from 90 prospectively investigated patients with suspected coronary artery disease who underwent MSCT (16-slice scanner, 0.5 mm collimation, 400 ms rotation time) prior to conventional coronary angiography for comparison of both approaches. Sensitivity and specificity of angiographic emulation [81% (26/32) and 93% (82/88)] were not significantly different from those of standard assessment [88% (28/32) and 99% (87/88)], while the per-case analysis time was significantly shorter for angiographic emulation than for standard assessment (3.4 {+-} 1.5 vs 7.0 {+-} 2.5 min, P < 0.001). Both interventional and referring cardiologists preferred angiographic emulation over standard curved multiplanar reformations of MSCT coronary angiography for illustration, mainly because of improved overall lucidity and depiction of sidebranches (P < 0.001). In conclusion, angiographic emulation of MSCT reduces analysis time, yields a diagnostic accuracy comparable to that of standard assessment, and is preferred by cardiologists for visualization of results. (orig.)

  6. Detection of coronary artery calcification with non triggered computed tomography of the chest

    Energy Technology Data Exchange (ETDEWEB)

    Pelandré, Gustavo Lemos; Sanches, Nathália Martins Pereira, E-mail: gustavo.pelandre@ufsc.br [Universidade Federal de Santa Catarina (UFSC), Florianópolis, SC (Brazil); Nacif, Marcelo Souto [Universidade Federal Fluminense (UFF), Niterói, RJ (Brazil); Marchiori, Edson [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil)

    2018-01-15

    Objective: To evaluate the accuracy of visual analysis and of the coronary artery calcium (CAC) score in non triggered computed tomography (CT), in comparison with that of the CAC score in electrocardiogram-triggered CT, in identifying coronary calcification. Materials and methods: A total of 174 patients for whom CT was indicated for CAC scoring underwent non triggered and triggered CT in a 64-channel multislice scanner, in a single session without a change in position. The images were interpreted by a radiologist with seven years of experience in thoracic and cardiovascular radiology. The measurement of coronary calcium was carried out by three methods: CAC score with dedicated software in non triggered CT, CAC score with dedicated software in triggered CT, and visual analysis without dedicated software in non triggered CT. Results: In non triggered CT, the CAC score presented an accuracy of 95.98% (95% CI: 91.93 - 98.04). The visual analysis showed an accuracy of 97.13% (95% CI: 93.45 - 98.77). Conclusion: Non triggered CT showed excellent accuracy in the identification and exclusion of coronary calcification, either the CAC score was determined with dedicated software or through visual analysis. (author)

  7. Noninvasive detection of coronary artery disease by dipyridamole-loading 201thallium myocardial scintigraphy

    International Nuclear Information System (INIS)

    Hamashige, Naohisa; Doi, Yoshinori; Yonezawa, Yoshihiro; Odawara, Hiroaki; Ozawa, Toshio; Akagi, Naoki; Yoshida, Shoji; Maeda, Tomoho

    1986-01-01

    Fifty patients with suspected coronary artery disease (CAD) were given i.v. infusion of 0.568 mg/kg of dipyridamole (DP) for 4 min in the supine position, and were loaded by stepping. Myocardial DP scanning (DP scintigraphy) was then performed with i.v. injection of 3 mCi of Tl-201 chloride. Findings were compared with those of coronary angiography and treadmill ECG. DP scintigraphy had higher sensitivity (90 %) and specificity (95 %) than treadmill ECG (76 % and 67 %) in diagnosing a ≥ 75 % coronary stenosis. Twenty nine patients had significant CAD: Reversible defects were associated with chest pain in 79 %, and with ST depression in 76 %. Not only relative differences in blood flow between the normal and diseased sites but also ischemia was suggested to be responsible for these defects. Increased rate pressure product by DP scintigraphy was slight (34 %) compared with that by treadmill ECG (105 %), suggesting a strong involvement of redistribution of coronary blood flow in the occurrence of ischemia. Increased myocardial oxygen consumption due to stepping was considered as the cause of ischemia as well, because the incidence of chest pain and ST depression was higher than previously reported. Chest pain and ST depression improved by i.v. injection of aminophylline. (Namekawa, K.)

  8. Comparative study of adenosine and exercise 201Tl myocardial perfusion tomographic imaging for detection of coronary heart disease

    International Nuclear Information System (INIS)

    Wang Xiong

    1997-01-01

    To compare diagnostic accuracy of adenosine and exercise 201 Tl myocardial perfusion tomographic imaging for detection of coronary heart disease (CHD) in patients with a normal rest ECG and no history of myocardial infarction, 81 patients with CHD and 10 normal control subjects underwent adenosine myocardial perfusion imaging, exercise nuclide myocardial perfusion imaging was performed in 117 patients with CHD and 16 normal control subjects, two groups also had coronary arteriography. Both exercise and adenosine testing parameters were analysed. It is shown: 1) The sensitivity and specificity for detection of CHD were 79% vs 80% for adenosine group and 81% vs 81% for exercise myocardial perfusion imaging group respectively. There was no significant difference in comparison with two matched groups (χ 2 = 1.13, χ 2 = 0.18, χ 2 = 0.12, P>0.05). 2) Side effects induced by adenosine accounted for 89% of patients, all symptoms were mild and disappeared quickly after the termination of the study except in 2 cases withdrawal of infusion needed because of severe angina pectoris. Adenosine myocardial perfusion imaging is a safe and sensitive method for detection of CHD. The diagnostic value of adenosine test is similar to that of exercise myocardial perfusion imaging and particularly useful in evaluating patients unable to perform exercise test or achieve adequate level of exercise

  9. Stress perfusion magnetic resonance imaging to detect coronary artery lesions in children.

    Science.gov (United States)

    Vijarnsorn, Chodchanok; Noga, Michelle; Schantz, Daryl; Pepelassis, Dion; Tham, Edythe B

    2017-05-01

    Stress perfusion cardiovascular magnetic resonance (CMR) is used widely in adult ischemic heart disease, but data in children is limited. We sought to evaluate feasibility, accuracy and prognostic value of stress CMR in children with suspected coronary artery disease (CAD). Stress CMR was reviewed from two pediatric centers over 5 years using a standard pharmacologic protocol. Wall motion abnormalities, perfusion deficits and late enhancement were correlated with coronary angiogram (CAG) when available, and clinical status at 1 year follow-up for major adverse cardiovascular events (MACE; coronary revascularization, non-fatal myocardial infarction and death due to CAD) was recorded. Sixty-four stress perfusion CMR studies in 48 children (10.9 ± 4.8 years) using adenosine; 59 (92%) and dipyridamole; 5 (8%), were reviewed. Indications were Kawasaki disease (39%), post arterial switch operation (12.5%), post heart transplantation (12.5%), post anomalous coronary artery repair (11%), chest pain (11%), suspected myocarditis or CAD (3%), post coronary revascularization (3%), and others (8%). Twenty-six studies were performed under sedation. Of all studies performed, 66% showed no evidence of ischemia or infarction, 28% had perfusion deficits and 6% had late gadolinium enhancement (LGE) without perfusion deficit. Compared to CAG, the positive predictive value (PPV) of stress CMR was 80% with negative predictive value (NPV) of 88%. At 1 year clinical follow-up, the PPV and NPV of stress CMR to predict MACE were 78 and 98%. Stress-perfusion CMR, in combination with LGE and wall motion-analysis is a feasible and an accurate method of diagnosing CAD in children. In difficult cases, it also helps guide clinical intervention by complementing conventional CAG with functional information.

  10. Coronary triglyceride deposition in contemporary advanced diabetics.

    Science.gov (United States)

    Ikeda, Yoshihiko; Zaima, Nobuhiro; Hirano, Ken-ichi; Mano, Masayuki; Kobayashi, Kunihisa; Yamada, Sohsuke; Yamaguchi, Satoshi; Suzuki, Akira; Kanzaki, Hideaki; Hamasaki, Toshimitsu; Kotani, Jun-ichi; Kato, Seiya; Nagasaka, Hironori; Setou, Mitsutoshi; Ishibashi-Ueda, Hatsue

    2014-07-01

    It is of importance to clarify pathophysiology of diabetic heart diseases such as heart failure and coronary artery disease. We reported a novel clinical phenotype called triglyceride deposit cardiomyovasculopathy (TGCV), showing aberrant TG accumulation in both coronary arteries and myocardium, in a cardiac transplant recipient. Here, we examined autopsied diabetics for TG deposition in cardiovasculature. Consecutive series of hearts from advanced diabetes mellitus (DM) subjects (DM group: DMG, n = 20) and those from age- and sex-matched non-diabetic controls (non DM group: NDMG, n = 20) were examined. The diagnostic criteria of 'advanced DM' was made based on 2014 Clinical Practice Recommendations proposed by the American Diabetes Association. The mean duration of DM was 15.8 years. All DMG suffered from heart diseases including coronary artery diseases and 14 subjects had multi-vessel disease. Tissue TG contents were measured biochemically. Coronary arterial TG contents was significantly higher in DMG compared with NDMG. Spatial distribution of TG in transverse sections of coronary arteries showed TG deposition mainly in smooth muscle cells by Imaging Mass Spectrometry. Abundant TG deposition in coronary artery might be associated with advanced DM. © 2014 Japanese Society of Pathology and Wiley Publishing Asia Pty Ltd.

  11. Reality of obesity paradox: Results of percutaneous coronary intervention in Middle Eastern patients.

    Science.gov (United States)

    Jarrah, Mohamad; Hammoudeh, Ayman J; Khader, Yousef; Tabbalat, Ramzi; Al-Mousa, Eyas; Okkeh, Osama; Alhaddad, Imad A; Tawalbeh, Loai Issa; Hweidi, Issa M

    2018-04-01

    Objective The aim of this study was to assess the baseline clinical characteristics, coronary angiographic features, and adverse cardiovascular events during hospitalization and at 1 year of follow-up in obese patients compared with overweight and normal/underweight patients. Methods A prospective, multicenter study of consecutive patients undergoing percutaneous coronary intervention was performed. Results Of 2425 enrolled patients, 699 (28.8%) were obese, 1178 (48.6%) were overweight, and 548 (22.6%) were normal/underweight. Obese patients were more likely to be female and to have a higher prevalence of diabetes, hypertension, hypercholesterolemia, or previous percutaneous coronary intervention. Acute coronary syndrome was the indication for percutaneous coronary intervention in 77.0% of obese, 76.4% of overweight, and 77.4% of normal/underweight patients. No significant differences in the prevalence of multi-vessel coronary artery disease or multi-vessel percutaneous coronary intervention were found among the three groups. Additionally, no significant differences were found in stent thrombosis, readmission bleeding rates, or cardiac mortality among the three groups during hospitalization, at 1 month, and at 1 year. Conclusion The major adverse cardiovascular event rate was the same among the three groups throughout the study period. Accordingly, body mass index is considered a weak risk factor for cardiovascular comorbidities in Arab Jordanian patients.

  12. Patient-related factors influencing detectability of coronary arteries in 320-row CT angiography in infants with complex congenital heart disease.

    Science.gov (United States)

    Yamasaki, Yuzo; Kawanami, Satoshi; Kamitani, Takeshi; Sagiyama, Koji; Shin, Seitaro; Hino, Takuya; Nagata, Hazumu; Yabuuchi, Hidetake; Nagao, Michinobu; Honda, Hiroshi

    2018-05-05

    To investigate the performance of second-generation 320-row computed tomographic (CT) angiography (CTA) in detecting coronary arteries and identify factors influencing visibility of the coronary arteries in infants with complex congenital heart disease (CHD). Data of 60 infants (aged 0-2 years, median 2 months) with complex CHD who underwent examination using 320-row CTA with low-dose prospective electrocardiogram-triggered volume target scanning were reviewed. The coronary arteries of each infant were assessed using a 0-4-point scoring system based on the number of coronary segments with a visible course. Clinical parameters, the CT value in the ascending aorta, image noise, and the radiation dose were subjected to univariate and multivariate analyses. The mean coronary score for all examinations was 2.6 ± 1.5 points. The mean attenuation in the ascending aorta was 306.7 ± 66.2 HU and the mean standard deviation was 21.7 ± 4.4. The mean effective radiation dose was 1.27 ± 0.39 mSv. Multivariate regression analysis showed significant correlations between coronary score and body weight (p < 0.05) and between coronary score and the CT value in the ascending aorta (p < 0.02). Second-generation 320-row CTA with prospective electrocardiogram-triggered volume target scanning and hybrid iterative reconstruction allows good visibility of the coronary arteries in infants with complex CHD. Body weight and the CT value in the ascending aorta are important factors influencing the visibility of the coronary arteries in infants.

  13. Comparison of 64-slice computed tomography angiography and coronary angiography for the detection and assessment of coronary artery disease in patients with angina: A systematic review

    International Nuclear Information System (INIS)

    Powell, H.; Cosson, P.

    2013-01-01

    Background: Coronary artery disease (CAD) is the leading cause of death in Western countries. It presents itself in various ways, the commonest being angina. According to the Royal College of Radiologist referral guidelines, Coronary Angiography (CA) is currently the gold standard for diagnosis and evaluation of CAD. However, due to the invasive nature and expense of CA there is a perceived need for a primary non-invasive imaging modality to supersede it. Computed tomography angiography (CTA), utilising 64-slice technology, may be a less invasive alternative to CA. Aim: To consider the research evidence for the current gold standard diagnostic test for CAD. Specifically, which is more sensitive and specific for detecting CAD in patients with angina; 64-slice CTA or CA? Inclusion Criteria: Prospective, non-randomised control trials and diagnostic accuracy studies comparing 64-slice CTA and CA were included. Participants were adults with angina with suspected or known CAD. Method: An electronic search of the databases; AMED, CINAHL, Cochrane Library, EMBASE, MEDLINE and Science Direct, was conducted between January 2004 and April 2012. Secondary hand-searching of grey literature was undertaken. Two reviewers independently determined studies for inclusion, assessed quality, using SIGN50, and extracted data. Diagnostic value of 64-slice CTA and CA was compared and analysed at patient and segment level. Results: Ten studies were included in the critical review enrolling 1188 patients. At patient level sensitivity for 64-slice CTA ranged from 88% to 100%, specificity 64–92%, PPV 86–97% and NPV 76.9–100%. At segment level sensitivity for 64-slice CTA ranged from 73% to 100%, specificity 83–98%, PPV 47–90% and NPV 89–100% Conclusion: At both patient and segment level, 64-slice CTA is a highly sensitive and specific non-invasive alternative to CA for diagnosis of significant stenosis in patients with angina. For standalone diagnosis of CAD current research would

  14. Evaluation of thallium-201 scanning for detection of latent coronary artery disease

    Science.gov (United States)

    Johnson, P. C.; Leblanc, A.; Deboer, L.; Jhingran, S.

    1978-01-01

    The use of thallium imaging as a noninvasive method to accurately screen shuttle passengers for latent coronary artery disease was investigated. All radionuclide procedures were performed using an Anger type camera with a high resolution collimator. A minimum of 200,000 counts were collected for each image using a 20% window centered on the 69-83 keV X-rays. For the images obtained following injection with the patient at rest, the testing was begun 10 minutes after injection. Injections of TT during exercise were made at a point near the termination of the treadmill procedure as determined by either the appearance of ST segment changes on the electrocardiogram consistant with subendocardial ischemia, the appearance of angina-like chest pain in the patient or fatigue in the patient which required cessation of the test. The severity of heart disease was based on the medical history, physical exam, exercise electrocardiograms, chest X-rays and the coronary arteriogram.

  15. Comparison of electron beam computed tomography and exercise electrocardiography in detecting coronary artery disease in the elderly

    International Nuclear Information System (INIS)

    Inoue, Shinji; Mitsunami, Kenichi; Kinoshita, Masahiko

    1998-01-01

    Although exercise electrocardiography (ECG) is a useful noninvasive screening test for coronary artery disease (CAD), one prerequisite for ECG screening is that patient be able to exercise enough to evoke myocardial ischemia. Thus, exercise ECG may not be suitable for, some elderly people with CAD who cannot exercise enough. We compared electron beam Computed Tomography (EBCT) with exercise ECG for detecting CAD in 196 patients (mean age, 58.4±12.5 (standard deviation)) who had undergone coronary angiography. Using the angiographic findings as the ''gold standard'', we found that the sensitivity, specificity, positive predictive value, and negative predictive value were 88%, 77%, 89%, and 77%, respectively, for EBCT, and 66%, 72%, 83%, and 52%, respectively, for exercise ECG. Although the results were similar when the subjects were divided into different age groups, the negative predictive value for exercise ECG, among older patients was very low. These findings suggest that EBCT is superior to exercise ECG in detecting CAD in the elderly. (author)

  16. Early detection of premature subclinical coronary atherosclerosis in systemic lupus erythematosus patients

    Directory of Open Access Journals (Sweden)

    Khaled Mohamed Said Othman

    2013-12-01

    Conclusion: Pre-menopausal SLE female patients free from clinical atherosclerotic vascular disease have an increased number of atherosclerotic plaques and CCS, which correlate positively with SLEDAI disease activity score, serum CRP, anticardiolipin antibodies, sICAM-1, E-Selectin, LDL level, total cholesterol level, and cumulative prednisone dose. In addition, we conclude that MDCT is a non-invasive, sensitive, reproducible, and reliable tool for accurate measurement of coronary calcification.

  17. Computerized detection of noncalcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Jun, E-mail: jvwei@umich.edu; Zhou, Chuan; Chan, Heang-Ping; Chughtai, Aamer; Agarwal, Prachi; Kuriakose, Jean; Hadjiiski, Lubomir; Patel, Smita; Kazerooni, Ella [Department of Radiology, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2014-08-15

    Purpose: The buildup of noncalcified plaques (NCPs) that are vulnerable to rupture in coronary arteries is a risk for myocardial infarction. Interpretation of coronary CT angiography (cCTA) to search for NCP is a challenging task for radiologists due to the low CT number of NCP, the large number of coronary arteries, and multiple phase CT acquisition. The authors conducted a preliminary study to develop machine learning method for automated detection of NCPs in cCTA. Methods: With IRB approval, a data set of 83 ECG-gated contrast enhanced cCTA scans with 120 NCPs was collected retrospectively from patient files. A multiscale coronary artery response and rolling balloon region growing (MSCAR-RBG) method was applied to each cCTA volume to extract the coronary arterial trees. Each extracted vessel was reformatted to a straightened volume composed of cCTA slices perpendicular to the vessel centerline. A topological soft-gradient (TSG) detection method was developed to prescreen for NCP candidates by analyzing the 2D topological features of the radial gradient field surface along the vessel wall. The NCP candidates were then characterized by a luminal analysis that used 3D geometric features to quantify the shape information and gray-level features to evaluate the density of the NCP candidates. With machine learning techniques, useful features were identified and combined into an NCP score to differentiate true NCPs from false positives (FPs). To evaluate the effectiveness of the image analysis methods, the authors performed tenfold cross-validation with the available data set. Receiver operating characteristic (ROC) analysis was used to assess the classification performance of individual features and the NCP score. The overall detection performance was estimated by free response ROC (FROC) analysis. Results: With our TSG prescreening method, a prescreening sensitivity of 92.5% (111/120) was achieved with a total of 1181 FPs (14.2 FPs/scan). On average, six features

  18. Computerized detection of noncalcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis

    International Nuclear Information System (INIS)

    Wei, Jun; Zhou, Chuan; Chan, Heang-Ping; Chughtai, Aamer; Agarwal, Prachi; Kuriakose, Jean; Hadjiiski, Lubomir; Patel, Smita; Kazerooni, Ella

    2014-01-01

    Purpose: The buildup of noncalcified plaques (NCPs) that are vulnerable to rupture in coronary arteries is a risk for myocardial infarction. Interpretation of coronary CT angiography (cCTA) to search for NCP is a challenging task for radiologists due to the low CT number of NCP, the large number of coronary arteries, and multiple phase CT acquisition. The authors conducted a preliminary study to develop machine learning method for automated detection of NCPs in cCTA. Methods: With IRB approval, a data set of 83 ECG-gated contrast enhanced cCTA scans with 120 NCPs was collected retrospectively from patient files. A multiscale coronary artery response and rolling balloon region growing (MSCAR-RBG) method was applied to each cCTA volume to extract the coronary arterial trees. Each extracted vessel was reformatted to a straightened volume composed of cCTA slices perpendicular to the vessel centerline. A topological soft-gradient (TSG) detection method was developed to prescreen for NCP candidates by analyzing the 2D topological features of the radial gradient field surface along the vessel wall. The NCP candidates were then characterized by a luminal analysis that used 3D geometric features to quantify the shape information and gray-level features to evaluate the density of the NCP candidates. With machine learning techniques, useful features were identified and combined into an NCP score to differentiate true NCPs from false positives (FPs). To evaluate the effectiveness of the image analysis methods, the authors performed tenfold cross-validation with the available data set. Receiver operating characteristic (ROC) analysis was used to assess the classification performance of individual features and the NCP score. The overall detection performance was estimated by free response ROC (FROC) analysis. Results: With our TSG prescreening method, a prescreening sensitivity of 92.5% (111/120) was achieved with a total of 1181 FPs (14.2 FPs/scan). On average, six features

  19. Outcomes of non-invasive diagnostic modalities for the detection of coronary artery disease: network meta-analysis of diagnostic randomised controlled trials.

    Science.gov (United States)

    Siontis, George Cm; Mavridis, Dimitris; Greenwood, John P; Coles, Bernadette; Nikolakopoulou, Adriani; Jüni, Peter; Salanti, Georgia; Windecker, Stephan

    2018-02-21

    To evaluate differences in downstream testing, coronary revascularisation, and clinical outcomes following non-invasive diagnostic modalities used to detect coronary artery disease. Systematic review and network meta-analysis. Medline, Medline in process, Embase, Cochrane Library for clinical trials, PubMed, Web of Science, SCOPUS, WHO International Clinical Trials Registry Platform, and Clinicaltrials.gov. Diagnostic randomised controlled trials comparing non-invasive diagnostic modalities in patients presenting with symptoms suggestive of low risk acute coronary syndrome or stable coronary artery disease. A random effects network meta-analysis synthesised available evidence from trials evaluating the effect of non-invasive diagnostic modalities on downstream testing and patient oriented outcomes in patients with suspected coronary artery disease. Modalities included exercise electrocardiograms, stress echocardiography, single photon emission computed tomography-myocardial perfusion imaging, real time myocardial contrast echocardiography, coronary computed tomographic angiography, and cardiovascular magnetic resonance. Unpublished outcome data were obtained from 11 trials. 18 trials of patients with low risk acute coronary syndrome (n=11 329) and 12 trials of those with suspected stable coronary artery disease (n=22 062) were included. Among patients with low risk acute coronary syndrome, stress echocardiography, cardiovascular magnetic resonance, and exercise electrocardiograms resulted in fewer invasive referrals for coronary angiography than coronary computed tomographic angiography (odds ratio 0.28 (95% confidence interval 0.14 to 0.57), 0.32 (0.15 to 0.71), and 0.53 (0.28 to 1.00), respectively). There was no effect on the subsequent risk of myocardial infarction, but estimates were imprecise. Heterogeneity and inconsistency were low. In patients with suspected stable coronary artery disease, an initial diagnostic strategy of stress echocardiography or

  20. Outcomes of non-invasive diagnostic modalities for the detection of coronary artery disease: network meta-analysis of diagnostic randomised controlled trials

    Science.gov (United States)

    Siontis, George CM; Mavridis, Dimitris; Greenwood, John P; Coles, Bernadette; Nikolakopoulou, Adriani; Jüni, Peter; Salanti, Georgia

    2018-01-01

    Abstract Objective To evaluate differences in downstream testing, coronary revascularisation, and clinical outcomes following non-invasive diagnostic modalities used to detect coronary artery disease. Design Systematic review and network meta-analysis. Data sources Medline, Medline in process, Embase, Cochrane Library for clinical trials, PubMed, Web of Science, SCOPUS, WHO International Clinical Trials Registry Platform, and Clinicaltrials.gov. Eligibility criteria for selecting studies Diagnostic randomised controlled trials comparing non-invasive diagnostic modalities in patients presenting with symptoms suggestive of low risk acute coronary syndrome or stable coronary artery disease. Data synthesis A random effects network meta-analysis synthesised available evidence from trials evaluating the effect of non-invasive diagnostic modalities on downstream testing and patient oriented outcomes in patients with suspected coronary artery disease. Modalities included exercise electrocardiograms, stress echocardiography, single photon emission computed tomography-myocardial perfusion imaging, real time myocardial contrast echocardiography, coronary computed tomographic angiography, and cardiovascular magnetic resonance. Unpublished outcome data were obtained from 11 trials. Results 18 trials of patients with low risk acute coronary syndrome (n=11 329) and 12 trials of those with suspected stable coronary artery disease (n=22 062) were included. Among patients with low risk acute coronary syndrome, stress echocardiography, cardiovascular magnetic resonance, and exercise electrocardiograms resulted in fewer invasive referrals for coronary angiography than coronary computed tomographic angiography (odds ratio 0.28 (95% confidence interval 0.14 to 0.57), 0.32 (0.15 to 0.71), and 0.53 (0.28 to 1.00), respectively). There was no effect on the subsequent risk of myocardial infarction, but estimates were imprecise. Heterogeneity and inconsistency were low. In patients with

  1. Detection of Altered Risk Factors in Hospitalized Patients with Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Avany Fernandes Pereira

    2002-09-01

    Full Text Available OBJECTIVE: To assess biochemical, anthropometric, and dietary variables considered risk factors for coronary artery disease. METHODS: Using anthropometrics, dietary allowance, and blood biochemistry, we assessed 84 patients [54 males (mean age of 55± 8 years and 30 females (mean age of 57±7 years], who had severe ( > or = 70% coronary artery obstruction and nonsevere forms of coronary artery disease determined by cardiac catheterization. The severe form of the disease prevailed in 70% of the males and 64% of the females, and a high frequency of familial antecedents (92% ' 88% and history of acute myocardial infarction (80% ' 70% were observed. Smoking predominated among males (65% and diabetes mellitus among females (43%. RESULTS: Males and females had body mass index and body fat above the normal values. Females with nonsevere lesions had HDL > 35 mg/dL, and this constituted a discriminating intergroup indicator. Regardless of the severity of the disease, hyperglycemia and hypertriglyceridemia were found among females, and cholesterolemia > 200 mg/dL in both sexes, but only males had LDL fraction > 160 mg/dL and homocysteine > 11.7 mmol/L. The male dietary allowance was inadequate in nutrients for homocysteine metabolism and in nutrients with an antioxidant action, such as the vitamins B6, C, and folate. Individuals of both sexes had a higher lipid and cholesterol intake and an inadequate consumption of fiber. The diet was classified as high-protein, high-fat, and low-carbohydrate. CONCLUSION: The alterations found had no association with the severity of lesions, indicating the need for more effective nutritional intervention.

  2. Iterative image reconstruction algorithms in coronary CT angiography improve the detection of lipid-core plaque - a comparison with histology

    International Nuclear Information System (INIS)

    Puchner, Stefan B.; Ferencik, Maros; Maurovich-Horvat, Pal; Nakano, Masataka; Otsuka, Fumiyuki; Virmani, Renu; Kauczor, Hans-Ulrich; Hoffmann, Udo; Schlett, Christopher L.

    2015-01-01

    To evaluate whether iterative reconstruction algorithms improve the diagnostic accuracy of coronary CT angiography (CCTA) for detection of lipid-core plaque (LCP) compared to histology. CCTA and histological data were acquired from three ex vivo hearts. CCTA images were reconstructed using filtered back projection (FBP), adaptive-statistical (ASIR) and model-based (MBIR) iterative algorithms. Vessel cross-sections were co-registered between FBP/ASIR/MBIR and histology. Plaque area 2 : 5.78 ± 2.29 vs. 3.39 ± 1.68 FBP; 5.92 ± 1.87 vs. 3.43 ± 1.62 ASIR; 6.40 ± 1.55 vs. 3.49 ± 1.50 MBIR; all p < 0.0001). AUC for detecting LCP was 0.803/0.850/0.903 for FBP/ASIR/MBIR and was significantly higher for MBIR compared to FBP (p = 0.01). MBIR increased sensitivity for detection of LCP by CCTA. Plaque area <60 HU in CCTA was associated with LCP in histology regardless of the reconstruction algorithm. However, MBIR demonstrated higher accuracy for detecting LCP, which may improve vulnerable plaque detection by CCTA. (orig.)

  3. Alpha adrenergic receptors in dog coronary arteries as detected with autoradiography

    International Nuclear Information System (INIS)

    Muntz, K.; Calianos, T.; Buja, L.M.

    1986-01-01

    The authors used previously established methods to determine the presence of alpha adrenergic receptors in different sizes of dog coronary arteries using autoradiography of 3 H-prazosin (PRAZ) and 125 I-BE 2254 (HEAT) to label alpha 1 adrenergic receptors and 3 H-rauwolscine (RAUW) to label alpha 2 adrenergic receptors. Frozen sections of the left main coronary artery (LMA), the left anterior descending artery (LAD) and myocardium were incubated in 3 concentrations of PRAZ (0.1, 0.5 and 1.0 nM) (n=5 dogs), 3 concentrations of RAUW (1, 3 and 5 nM) (n=5) and one concentration of HEAT (50 pM) (n=3). All incubations were done in the absence of (total binding) or presence of (nonspecific binding) 10 -5 M phentolamine or yohimbine. The sections were processed for autoradiography and silver grains quantitated using an image analyzer. Analysis of variance determined that there was a significant difference between total and nonspecific binding in the LMA incubated with PRAZ (p 1 receptors decreases as vessel size decreases, while the number of alpha 2 receptors increases as vessel size decreases

  4. Comparison of CTAC and prone imaging for the detection of coronary artery disease using CZT SPECT.

    Science.gov (United States)

    Ito, Shimpei; Endo, Akihiro; Okada, Taiji; Nakamura, Taku; Sugamori, Takashi; Takahashi, Nobuyuki; Yoshitomi, Hiroyuki; Tanabe, Kazuaki

    2017-10-01

    Cadmium-zinc-telluride (CZT) cameras have improved the evaluation of patients with chest pain. However, inferior/inferolateral attenuation artifacts similar to those seen with conventional Anger cameras persist. We added prone acquisitions and CT attenuation correction (CTAC) to the standard supine image acquisition and analyzed the resulting examinations. Seventy-two patients referred for invasive coronary angiography (CAG), and who also underwent rest/stress myocardial perfusion imaging (MPI) on a CZT camera in the supine and prone positions plus CTAC imaging, to examine known or suspected CAD between April 2013 and March 2014 were included. A sixteen-slice CT scan acquired on a SPECT/CT scanner between rest and stress imaging provided data for iterative reconstruction. Sensitivity, specificity, accuracy, and positive and negative likelihood ratios (LRs) were calculated to compare MPI with CAG on a per-patient basis. Per-patient sensitivity, specificity, and accuracy of supine images to predict coronary abnormalities on CAG were 35% [95% confidence interval (CI) 19-52], 86% (95% CI 80-92), and 74% (95% CI 66-82); those of prone imaging were 65% (95% CI 45-81), 82% (95% CI 76-87), and 78% (95% CI 68-85); and those of CTAC were 59% (95% CI 41-71), 93% (95% CI 87-97), and 85% (95% CI 76-91), respectively. Prone acquisition and CTAC images improve the ability to assess the inferior/inferolateral area.

  5. Comparison of single-dose and double-dose thallium-201 myocardial perfusion scintigraphy for the detection of coronary artery disease and prior myocardial infarction

    International Nuclear Information System (INIS)

    Blood, D.K.; McCarthy, D.M.; Sciacca, R.R.; Cannon, P.J.

    1978-01-01

    Thallium-201 myocardial perfusion scintigraphy was performed after exercise, 4 hours after exercise (redistribution) and after a separate rest injection in 87 patients undergoing coronary arteriography. Significant coronary lesions were present in 62 of the patients. Interpretation of the rest and redistribution scintiscans was the same in 69 patients, 45 of whom had coronary artery disease (CAD). In 16 of the 17 patients with CAD and differing interpretations, defects were present on redistribution scintiscans but not on rest scintiscans; 11 of these patients had evidence of prior transmural myocardial infarction and the other five had an occluded coronary artery supplying the region of the defect. Redistribution scintiscans were more sensitive than rest scintiscans for the detection of prior myocardial infarction (93% vs 54%; P < 0.01). The increased sensitivity was confined to the detection of prior inferior myocardial infarctions. In 36 of 38 patients with persistent perfusion defects on 4-hour redistribution scintiscans, either a prior infarction or an occluded coronary vessel was present. These data demonstrate that redistribution thallium-201 scintiscans may be substituted for conventional rest scintiscans, resulting in reduced cost and radiation exposure to the patients

  6. Sudden cardiac death and coronary disease in the young

    DEFF Research Database (Denmark)

    Zachariasardóttir, Sára; Risgaard, Bjarke; Ågesen, Frederik Nybye

    2017-01-01

    BACKGROUND: Sudden cardiac death caused by coronary artery disease (CAD-SCD) is the most frequent cause of SCD in persons ..., CAD-SCD victims aged 36-49years had more severe atherosclerosis in all coronary arteries, more multi-vessel disease (29% vs. 15%, p=0.049) and less commonly (38% vs. 54%, p=0.039) acute coronary occlusion than victims ... to death. CONCLUSION: This nationwide study found several differences in the pathologic lesions of the heart in victims aged 18-35 and 36-49years, which might be associated with different disease progression leading to death in these age groups. We also report a high frequency of cardiac symptoms prior...

  7. Serial thallium-201 imaging after dipyridamole for coronary disease detection: quantitative analysis using myocardial clearance

    International Nuclear Information System (INIS)

    Okada, R.D.; Dai, Y.H.; Boucher, C.A.; Pohost, G.M.

    1984-01-01

    After dipyridamole, canine studies have demonstrated a slower rate of myocardial thallium-201 clearance from zones distal to a coronary artery stenosis compared to normal zones. To determine if criteria based on canine myocardial thallium-201 clearance rates could be applied clinically, 40 patients with and 26 patients without coronary artery disease (CAD) had serial thallium-201 images obtained for 2 to 5 hours after dipyridamole. Regions of interest were manually placed over six left ventricular segments in two projections for each of three imaging times. The myocardial thallium-201 clearance rate was calculated for each of the six segments and, using the clearance rate criterion found in canine studies, was considered abnormal if less than 6.5%/hr. Using this criterion alone, 22 of 26 patients (85%) without CAD had normal and 30 of 40 patients (75%) with CAD had abnormal myocardial thallium-201 clearance rates. A quantitative analysis of regional inhomogeneity in tracer distribution (normal was greater than or equal to 25% difference between segments) was negative in 24 of 26 patients (92%) without CAD and positive in 20 of 40 patients (50%) with CAD. When both clearance rate and regional inhomogeneity were considered, 21 of 26 patients (81%) without CAD had negative and 36 of 40 patients (90%) with CAD had positive results. Thus, post-dipyridamole myocardial clearance rate criteria derived from canine studies can be applied to clinical thallium imaging. Quantitative analysis of serial thallium-201 images after dipyridamole is optimized by using myocardial thallium-201 clearance rates. Such an approach is independent of regional inhomogeneities in tracer distribution

  8. Comparison of exercise electrocardiography and stress perfusion CMR for the detection of coronary artery disease in women

    Directory of Open Access Journals (Sweden)

    Greulich Simon

    2012-06-01

    Full Text Available Abstract Background Exercise electrocardiography (ECG is frequently used in the work-up of patients with suspected coronary artery disease (CAD, however the accuracy is reduced in women. Cardiovascular magnetic resonance (CMR stress testing can accurately diagnose CAD in women. To date, a direct comparison of CMR to ECG has not been performed. Methods and results We prospectively enrolled 88 consecutive women with chest pain or other symptoms suggestive of CAD. Patients underwent a comprehensive clinical evaluation, exercise ECG, a CMR stress test including perfusion and infarct imaging, and x-ray coronary angiography (CA within 24 hours. CAD was defined as stenosis ≥70% on quantitative analysis of CA. Exercise ECG, CMR and CA was completed in 68 females (age 66.4 ± 8.8 years, number of CAD risk factors 3.5 ± 1.4. The prevalence of CAD on CA was 29%. The Duke treadmill score (DTS in the entire group was −3.0 ± 5.4 and was similar in those with and without CAD (−4.5 ± 5.8 and −2.4 ± 5.1; P = 0.12. Sensitivity, specificity and accuracy for CAD diagnosis was higher for CMR compared with exercise ECG (sensitivities 85% and 50%, P = 0.02, specificities 94% and 73%, P = 0.01, and accuracies 91% and 66%, P = 0.0007, respectively. Even after applying the DTS the accuracy of CMR was higher compared to exercise ECG (area under ROC curve 0.94 ± 0.03 vs 0.56 ± 0.07; P = 0.0001. Conclusions In women with intermediate-to-high risk for CAD who are able to exercise and have interpretable resting ECG, CMR stress perfusion imaging has higher accuracy for the detection of relevant obstruction of the epicardial coronaries when directly compared to exercise ECG.

  9. Iterative image reconstruction algorithms in coronary CT angiography improve the detection of lipid-core plaque - a comparison with histology

    Energy Technology Data Exchange (ETDEWEB)

    Puchner, Stefan B. [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); Medical University of Vienna, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Ferencik, Maros [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); Harvard Medical School, Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Maurovich-Horvat, Pal [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); Semmelweis University, MTA-SE Lenduelet Cardiovascular Imaging Research Group, Heart and Vascular Center, Budapest (Hungary); Nakano, Masataka; Otsuka, Fumiyuki; Virmani, Renu [CV Path Institute Inc., Gaithersburg, MD (United States); Kauczor, Hans-Ulrich [University Hospital Heidelberg, Ruprecht-Karls-University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Hoffmann, Udo [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); Schlett, Christopher L. [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); University Hospital Heidelberg, Ruprecht-Karls-University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany)

    2015-01-15

    To evaluate whether iterative reconstruction algorithms improve the diagnostic accuracy of coronary CT angiography (CCTA) for detection of lipid-core plaque (LCP) compared to histology. CCTA and histological data were acquired from three ex vivo hearts. CCTA images were reconstructed using filtered back projection (FBP), adaptive-statistical (ASIR) and model-based (MBIR) iterative algorithms. Vessel cross-sections were co-registered between FBP/ASIR/MBIR and histology. Plaque area <60 HU was semiautomatically quantified in CCTA. LCP was defined by histology as fibroatheroma with a large lipid/necrotic core. Area under the curve (AUC) was derived from logistic regression analysis as a measure of diagnostic accuracy. Overall, 173 CCTA triplets (FBP/ASIR/MBIR) were co-registered with histology. LCP was present in 26 cross-sections. Average measured plaque area <60 HU was significantly larger in LCP compared to non-LCP cross-sections (mm{sup 2}: 5.78 ± 2.29 vs. 3.39 ± 1.68 FBP; 5.92 ± 1.87 vs. 3.43 ± 1.62 ASIR; 6.40 ± 1.55 vs. 3.49 ± 1.50 MBIR; all p < 0.0001). AUC for detecting LCP was 0.803/0.850/0.903 for FBP/ASIR/MBIR and was significantly higher for MBIR compared to FBP (p = 0.01). MBIR increased sensitivity for detection of LCP by CCTA. Plaque area <60 HU in CCTA was associated with LCP in histology regardless of the reconstruction algorithm. However, MBIR demonstrated higher accuracy for detecting LCP, which may improve vulnerable plaque detection by CCTA. (orig.)

  10. Incremental Diagnostic Performance of Combined Parameters in the Detection of Severe Coronary Artery Disease Using Exercise Gated Myocardial Perfusion Imaging.

    Directory of Open Access Journals (Sweden)

    Chia-Ju Liu

    Full Text Available Myocardial perfusion imaging (MPI using gated single-photon emission tomography (gSPECT may underestimate the severity of coronary artery disease (CAD. This study aimed to evaluate the significance of combined parameters derived from gSPECT, as well as treadmill stress test parameters, in the detection of severe CAD.A total of 211 consecutive patients referred for exercise MPI between June 2011 and June 2013 (who received invasive coronary angiography within six months after MPI were retrospectively reviewed. Exercise MPI was performed with Bruce protocol and 201Tl injected at peak exercise. Gated SPECT was performed using a cadmium-zinc-telluride camera and processed by QPS/QGS software. Perfusion defect abnormalities such as sum stress score (SSS; sum difference score, algorithm-derived total perfusion deficits, transient ischemic dilatation ratios of end-diastolic volumes and end-systolic volumes, post-stress changes in ejection fraction, and lung/heart ratio (LHR were calculated. Treadmill parameters, including ST depression (STD at the 1st and 3rd minutes of recovery stage (1'STD and 3'STD, maximal STD corrected by heart rate increment (ST/HR, heart rate decline in 1st and 3rd minutes of recovery stage, recovery heart rate ratio (HR ratio, systolic and mean blood pressure ratios (SBP ratio and MAP ratio during recovery phase were recorded. Diagnostic performances of these parameters were analyzed with receiver operating characteristic (ROC analysis and logistic regression for detection of left main (≥ 50% or 3-vessel disease (all ≥ 70% luminal stenosis on invasive angiography.Among various MPI and treadmill parameters used for detection of severe CAD, SSS and ST/HR had the highest AUC (0.78, 0.73, p = NS and best cut-off values (SSS > 6, ST/HR > 17.39 10-2mV/bpm, respectively. By univariate logistic regression, all parameters except 1'HRR, 3'HRR, SBP and MAP ratios increased the odds ratio of severe CAD. Only increased L/H ratio, 3'STD

  11. Association between smoking habits and severity of coronary stenosis as assessed by coronary computed tomography angiography.

    Science.gov (United States)

    Yano, Masaya; Miura, Shin-Ichiro; Shiga, Yuhei; Miyase, Yuiko; Suematsu, Yasunori; Norimatsu, Kenji; Nakamura, Ayumi; Adachi, Sen; Nishikawa, Hiroaki; Saku, Keijiro

    2016-07-01

    Smoking promotes arteriosclerosis and is one of the most important coronary risk factors. However, few studies have investigated the association between smoking habits and the severity of coronary stenosis as assessed by coronary computed tomography angiography (CTA). We enrolled 416 patients [165/251 = smoker (past and current)/non-smoker)]. They had all undergone CTA and either were clinically suspected of having coronary artery disease (CAD) or had at least one cardiovascular risk factor. We divided the patients into smoking and non-smoking groups, and evaluated the presence of CAD, the number of significantly stenosed coronary vessels (VD), and the Gensini score as assessed by CTA in the two groups. The incidence of CAD, VD, the Gensini score, and coronary calcification score in the smoking group were all significantly greater than those in the non-smoking group (CAD, p = 0.009; VD, p = 0.003; Gensini score, p = 0.007; coronary calcification score, p = 0.01). Pack-year was significantly associated with VD and the Gensini score, and was strongly associated with multi-vessel disease (2- and 3-VD) (p < 0.05), whereas the duration of cessation in past smokers was not associated with VD or the Gensini score. Pack-year, but not the duration of cessation, may be the most important factor that was associated with the severity of coronary stenosis in terms of VD and the Gensini score.

  12. Non-invasive assessment of coronary calcification

    International Nuclear Information System (INIS)

    Vliegenthart, Rozemarijn; Oei, Hok-Hay S.; Hofman, Albert; Oudkerk, Matthijs; Witteman, Jackqueline C. M.

    2004-01-01

    Electron-beam tomography (EBT) and multi-detector computed tomography (MDCT) enable the noninvasive assessment of coronary calcification. The amount of coronary calcification, as detected by EBT, has a close relation with the amount of coronary atherosclerosis, which is the substrate for the occurrence of myocardial infarction and sudden cardiac death. Calcification of the coronary arteries can be seen as a cumulative measure of life-time exposure to cardiovascular risk factors. Several studies have shown that the amount of coronary calcification is associated with the risk of coronary heart disease. Therefore, coronary calcification is a promising method for non-invasive detection of asymptomatic subjects at high risk of developing coronary heart disease. Whether measurement of coronary calcification also increases the predictive power of coronary events based on cardiovascular risk factors is topic of current research

  13. Quantitative analysis of arterial flow properties for detection of non-calcified plaques in ECG-gated coronary CT angiography

    Science.gov (United States)

    Wei, Jun; Zhou, Chuan; Chan, Heang-Ping; Chughtai, Aamer; Agarwal, Prachi; Kuriakose, Jean; Hadjiiski, Lubomir; Patel, Smita; Kazerooni, Ella

    2015-03-01

    We are developing a computer-aided detection system to assist radiologists in detection of non-calcified plaques (NCPs) in coronary CT angiograms (cCTA). In this study, we performed quantitative analysis of arterial flow properties in each vessel branch and extracted flow information to differentiate the presence and absence of stenosis in a vessel segment. Under rest conditions, blood flow in a single vessel branch was assumed to follow Poiseuille's law. For a uniform pressure distribution, two quantitative flow features, the normalized arterial compliance per unit length (Cu) and the normalized volumetric flow (Q) along the vessel centerline, were calculated based on the parabolic Poiseuille solution. The flow features were evaluated for a two-class classification task to differentiate NCP candidates obtained by prescreening as true NCPs and false positives (FPs) in cCTA. For evaluation, a data set of 83 cCTA scans was retrospectively collected from 83 patient files with IRB approval. A total of 118 NCPs were identified by experienced cardiothoracic radiologists. The correlation between the two flow features was 0.32. The discriminatory ability of the flow features evaluated as the area under the ROC curve (AUC) was 0.65 for Cu and 0.63 for Q in comparison with AUCs of 0.56-0.69 from our previous luminal features. With stepwise LDA feature selection, volumetric flow (Q) was selected in addition to three other luminal features. With FROC analysis, the test results indicated a reduction of the FP rates to 3.14, 1.98, and 1.32 FPs/scan at sensitivities of 90%, 80%, and 70%, respectively. The study indicated that quantitative blood flow analysis has the potential to provide useful features for the detection of NCPs in cCTA.

  14. Clinical value of 201Tl lung/heart ratio during exercise in hypertensive patients with coronary artery disease

    International Nuclear Information System (INIS)

    Ouyang Wei; He Guorong; Liu Jinhua; Huang Yuying

    2002-01-01

    Objective: The purpose of the study was to evaluate the relationship between 201 Tl lung/heart ratio during exercise and left ventricular diastolic function and its diagnostic value on severity of coronary artery disease. Methods: One hundred and two patients with documented coronary artery disease were divided into three groups, including no hypertension, hypertension without or with left ventricular hypertrophy groups. Exercise/delay 201 Tl myocardial perfusion tomography was performed on all patients included. Lung/heart ratio was defined on the anterior planar image obtained during exercise tomography. Results: The lung/heart ratios during exercise in no hypertension (0.43 +- 0.09, P 0.05). The lung/heart ratios of multi-vessel disease subgroup in no hypertension (0.46 +- 0.10 vs 0.40 +- 0.09, P 0.05). When lung/heart ratio was≥0.45, the sensitivities for predicting the presence of multi-vessel disease were 82%, 90%, 40% and specificities were 75%, 75%, 45%, respectively, in no hypertension, hypertension without and with hypertrophy groups. In no hypertension (r=0.402, P 0.05). In no hypertension (r=-0.413, P<0.01), hypertension without (r=-0.662, P<0.01) and with hypertrophy groups (r=-0.408, P<0.05), lung/heart ratios all showed a significant reverse correlation with correspondent E/A ratios. Conclusions: The exercise lung/heart ratios has a better diagnostic value for multi-vessel disease and left ventricular diastolic function abnormalities of coronary artery disease with or without hypertension, but not for multi-vessel disease in hypertension patients complicated with myocardial hypertrophy

  15. Role of stress myocardial perfusion SPECT scan in detection and management of coronary artery disease: Nairobi experience

    International Nuclear Information System (INIS)

    Makhdomi, K.B.; Warshow, M.M.; Patel, P.K.J.; Shah, D.; Githegi, D.R.M.

    2002-01-01

    Aim: Stress myocardial perfusion scans have acquired a significant role in the detection and management of Coronary Artery Disease. However, this mode of investigation has only recently been available in Nairobi, and this is the first such study from East Africa. We undertook a comparison of our results with that in the literature, to see whether they conformed to it. Materials and Methods: We performed a review of our initial 82 evaluable studies. The scans were performed with 99mTc-Tetrofosmin, using the single day stress-rest protocol with SPECT acquisitions. We carried out a correlation of our scan findings with angiographic data (where available), and clinical follow-up. The clinical end points where furnished by the referring physicians. We focused on myocardial infarction, need for re-vascularisation, and death. The mean clinical follow-up was 21.8 months (range of 12 months to 39 months). Results: Eighty (98%) of the studies revealed concordance with angiographic findings and/or were predictive of clinical outcome. Two studies were discordant, and will be discussed. The results are comparable with those in the literature. Conclusion: It is concluded that stress myocardial perfusion studies, done at our Centre, had a good predictive value, with regards to the presence and severity of disease, and correlated with the clinical outcome data

  16. Coronary angioplasty with second generation Monorail catheters.

    Science.gov (United States)

    Pande, A K; Meier, B; Urban, P; Villavicencio, R; de la Serna, F; Moles, V

    1991-07-01

    The Monorail system (Schneider) consists of a balloon catheter in which the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the length of the guiding catheter. It offers distinct advantages over conventional systems of coronary angioplasty. It facilitates contrast injections and permits rapid balloon exchanges. This system was used for coronary angioplasty in 273 unselected consecutive patients (age 59 +/- 10, mean 35 to 73 years). There were 216 patients (84%) undergoing single-vessel and 57 patients (16%) with multi-vessel coronary angioplasty. A total of 335 coronary stenoses were dilated, which included 35 total occlusions. The size of balloon used ranged from 2.0 to 4.25 mm (3.0 +/- 0.5 mm) and the severity of stenosis was 85 +/- 11%. Technical success was defined as a residual stenosis of less than 50% as determined angiographically. Clinical success was defined as technical success, and absence of a major inhospital complication defined as absence of myocardial infarction, lack of need for coronary arterial bypass surgery, and survival. The Monorail system was technically successful in 294/300 stenotic lesions (98%). It was clinically successful for 281 lesions (94%). Of the 35 total occlusions, technical success was obtained in 25 (71%). The residual stenosis of successful cases was 26 +/- 21%. The Monorail system was also successful in 5 patients with stenosis of more than 90% in whom conventional systems failed. The complications included acute occlusion causing acute myocardial infarction in 13 cases (5%), emergency coronary arterial bypass surgery in 1 patient (0.4%), and death in 4 patients (1.5%).(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Comparison of Diagnostic Accuracy for Detecting coronary Artery Disease of Dipyridamole 99mTc-MIBI Myocardial SPECT and It's Defect Map between Men and Women

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Oh, Byung Hee; Chung, June Key; Lee, Myoung Mook; Park, Young Bae; Lee, Myung Chul; Seo, Jung Don; Lee, Young Woo; Koh, Chang Soon

    1993-01-01

    To evaluate the usefulness and differences in diagnosing coronary artery disease (CAD) between men and women of intravenous dipyridamole 99m Tc-MIBI myocardial SPECT, we obtained 99m Tc-MIBI myocardial SPECT and compared with the findings of coronary angiographies. Ninety eight male and 37 female patients who underwent dipyridamole 99m Tc- MIBI myocardial imaging within one month of cardiac catheterization were studied. Scans were considered abnormal if perfusion defect was detected and the defect size was more than 12% for left anterior descending artery (LAD) and circumflex(LCX) and 8% for right coronary artery (RCA) territories. Lesions ≥ 50% luminal diameter narrowing were considered significant CAD. Overall sensitivity for detection of CAD was 94.3% in men and 96.4% in women; specificity was 70% in men and 52.6% in women (P=not significant, ns). Vessel-matched sensitivity was 75.3% in men and 72.7% in women (P=ns); specificity was 84.6% in men and 67.9% in women (P 99m Tc-MIBI myocardial SPECT is a safe, noninvasive test for evaluation of CAD. There was no gender difference to detect CAD, but more false-positive rate in women especially in the territory of LAD.

  18. Comparison of Quantitative Wall Motion Analysis and Strain For Detection Of Coronary Stenosis With Three-Dimensional Dobutamine Stress Echocardiography

    Science.gov (United States)

    Parker, Katherine M.; Clark, Alexander P.; Goodman, Norman C.; Glover, David K.; Holmes, Jeffrey W.

    2015-01-01

    Background Quantitative analysis of wall motion from three-dimensional (3D) dobutamine stress echocardiography (DSE) could provide additional diagnostic information not available from qualitative analysis. In this study we compare the effectiveness of 3D fractional shortening (3DFS), a measure of wall motion computed from 3D echocardiography (3DE), to strain and strain rate measured with sonomicrometry for detecting critical stenoses during DSE. Methods Eleven open-chest dogs underwent DSE both with and without a critical stenosis. 3DFS was measured from 3DE images acquired at peak stress. 3DFS was normalized by subtracting average 3DFS during control peak stress (Δ3DFS). Strains in the perfusion defect (PD) were measured from sonomicrometry, and PD size and location were measured with microspheres. Results A Δ3DFS abnormality indicated the presence of a critical stenosis with high sensitivity and specificity (88% and 100%, respectively), and Δ3DFS abnormality size correlated with PD size (R2=0.54). The sensitivity and specificity for Δ3DFS was similar to that for area strain (88%, 100%) and circumferential strain and strain rate (88%, 92% and 88%, 86%, respectively), while longitudinal strain and strain rate were less specific. Δ3DFS correlated significantly with both coronary flow reserve (R2=0.71) and PD size (R2=0.97), while area strain correlated with PD size only (R2=0.67), and other measures were not significantly correlated with flow reserve or PD size. Conclusion Quantitative wall motion analysis using Δ3DFS is effective for detecting critical stenoses during DSE, performing similarly to 3D strain, and provides potentially useful information on the size and location of a perfusion defect. PMID:24815588

  19. The use of simple indicators for detecting potential coronary heart disease susceptibility in the air traffic controller population.

    Science.gov (United States)

    1972-05-01

    An analysis was made of an eight-year interval change in several indicators of coronary heart disease (CHD) susceptibility as measured on 475 male air traffic control (ATC) personnel. The initial measurements were obtained from these personnel as ATC...

  20. The use of simple indicators for detecting potential coronary heart disease susceptibility in the third-class airman population.

    Science.gov (United States)

    1972-07-01

    An analysis was made of an eight-year interval change in several Framingham Heart Study (FHS) indicators of coronary heart disease (CHD) susceptibility as measured on 475 male air traffic control (ATC) personnel. The initial measurements were obtaine...

  1. Prevalence, Impact, and Predictive Value of Detecting Subclinical Coronary and Carotid Atherosclerosis in Asymptomatic Adults

    DEFF Research Database (Denmark)

    Baber, Usman; Mehran, Roxana; Sartori, Samantha

    2015-01-01

    BACKGROUND: Although recent studies suggest that measuring coronary artery calcification (CAC) may be superior to indirect atherosclerotic markers in predicting cardiac risk, there are limited data evaluating imaging-based biomarkers that directly quantify atherosclerosis in different vascular beds...

  2. Influence of a small field-of-view size on the detection of coronary artery calcifications with MSCT: in vitro and in vivo study

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Muehlenbruch, Georg; Das, Marco; Pohl, Saskia; Guenther, Rolf W.; Wildberger, Joachim E.; Koos, Ralf; Stanzel, Sven

    2006-01-01

    The purpose of this study is to asses the impact of small field-of-view (FOV) sizes on the detection of coronary artery calcifications using multislice-spiral computed tomography (MSCT). First, a static chest phantom containing calcium inserts was scanned 10 times using a standardized scan protocol. Secondly, 50 patients (28 male, 63.6±10.6 years) underwent cardiac MSCT using the same protocol. Images were reconstructed with three different FOV sizes (180 x 180, 220 x 220, 380 x 380 mm 2 ). Coronary calcium scoring and risk stratification were performed for each image series. In the phantom study, the Agatston score calculated with a FOV size of 180 x 180 mm 2 was 657.80±20.05. At a FOV of 220 x 220 mm 2 and 380 x 380 mm 2 , the corresponding values were 657.04±21.36 and 655.04±20.74, respectively. The corresponding values in the patient study were 541.65±869.87, 541.91±872.57 and 536.61±867.81. No statistically significant differences in the calcium score were found comparing different FOV sizes. Significantly more lesions (p=0.00149) were detected in the patient study. Comparing the different FOV sizes of 180 x 180 mm 2 and 220 x 220 mm 2 (380 x 380 mm 2 ), four (six) patients had to be assigned to different risk groups. The use of small FOV sizes resulted in an improved detection of coronary calcifications influencing the risk stratification for further cardiac events in MSCT coronary calcium scoring. (orig.)

  3. Coronary artery anatomy and variants

    Energy Technology Data Exchange (ETDEWEB)

    Malago, Roberto; Pezzato, Andrea; Barbiani, Camilla; Alfonsi, Ugolino; Nicoli, Lisa; Caliari, Giuliana; Pozzi Mucelli, Roberto [Policlinico G.B. Rossi, University of Verona, Department of Radiology, Verona (Italy)

    2011-12-15

    Variants and congenital anomalies of the coronary arteries are usually asymptomatic, but may present with severe chest pain or cardiac arrest. The introduction of multidetector CT coronary angiography (MDCT-CA) allows the detection of significant coronary artery stenosis. Improved performance with isotropic spatial resolution and higher temporal resolution provides a valid alternative to conventional coronary angiography (CCA) in many patients. MDCT-CA is now considered the ideal tool for three-dimensional visualization of the complex and tortuous anatomy of the coronary arteries. With multiplanar and volume-rendered reconstructions, MDCT-CA may even outperform CCA in determining the relative position of vessels, thus providing a better view of the coronary vascular anatomy. The purpose of this review is to describe the normal anatomy of the coronary arteries and their main variants based on MDCT-CA with appropriate reconstructions. (orig.)

  4. Coronary MR angiography: current status

    International Nuclear Information System (INIS)

    Danias, P.G.; Manning, W.J.

    2000-01-01

    Since first described in the early 1990s, coronary magnetic resonance angiography (MRA) has evolved as a promising noninvasive modality for imaging of the coronary arteries and evaluation of coronary artery disease. Despite technical limitations, coronary MRA has established value for imaging of anomalous coronary arteries and assessment of bypass graft patency. Current research focuses on the development of optimal respiratory compensation strategies, improved spatial and temporal resolution and faster acquisition of image data. The accurate detection of stenoses and assessment of the severity of coronary atherosclerosis is presently being evaluated with large multi-center studies. With further technique enhancements and more clinical experience, coronary MRA is likely to become the dominant noninvasive modality in clinical cardiology. (orig.) [de

  5. Multicolor fluorescence technique to detect apoptotic cells in advanced coronary atherosclerotic plaques

    Directory of Open Access Journals (Sweden)

    C Soldani

    2009-06-01

    Full Text Available Apoptosis occurring in atherosclerotic lesions has been suggested to be involved in the evolution and the structural stability of the plaques. It is still a matter of debate whether apoptosis mainly involves vascular smooth muscle cells (vSMCs in the fibrous tissue or inflammatory (namely foam cells, thus preferentially affecting the cell-poor lipid core of the atherosclerotic plaques. The aim of the present investigation was to detect the presence of apoptotic cells and to estimate their percentage in a series of atherosclerotic plaques obtained either by autopsy or during surgical atherectomy. Apoptotic cells were identified on paraffinembedded sections on the basis of cell nuclear morphology after DNA staining and/or by cytochemical reactions (TUNEL assay, immunodetection of the proteolytic poly (ADP-ribose polymerase-1 [PARP-1] fragment; biochemical procedures (identifying DNA fragmentation or PARP-1 proteolysis were also used. Indirect immunofluorescence techniques were performed to label specific antigens for either vSMCs or macrophages (i.e., the cells which are most likely prone to apoptosis in atherosclerotic lesions: the proper selection of fluorochrome labeling allowed the simultaneous detection of the cell phenotype and the apoptotic characteristics, by multicolor fluorescence techniques. Apoptotic cells proved to be less than 5% of the whole cell population, in atherosclerotic plaque sections: this is, in fact, a too low cell fraction to be detected by widely used biochemical methods, such as agarose gel electrophoresis of low-molecular-weight DNA or Western-blot analysis of PARP-1 degradation. Most apoptotic cells were of macrophage origin, and clustered in the tunica media, near or within the lipid-rich core; only a few TUNEL-positive cells were labeled for antigens specific for vSMCs. These results confirm that, among the cell populations in atherosclerotic plaques, macrophage foam-cells are preferentially involved in apoptosis

  6. Stability of multilead ST-segment "fingerprints" over time after percutaneous transluminal coronary angioplasty and its usefulness in detecting reocclusion.

    Science.gov (United States)

    Krucoff, M W; Parente, A R; Bottner, R K; Renzi, R H; Stark, K S; Shugoll, R A; Ahmed, S W; DeMichele, J; Stroming, S L; Green, C E

    1988-06-01

    Multilead ST-segment recordings taken during percutaneous transluminal coronary angioplasty (PTCA) could function as an individualized noninvasive template or "fingerprint," useful in evaluating transient ischemic episodes after leaving the catheterization laboratory. To evaluate the reproducibility of such ST-segment patterns over time, these changes were analyzed in patients grouped according to the time between occlusion and reocclusion. For the patients in group 1, the study required comparing their "fingerprints" in repeat balloon inflation during PTCA (reocclusion in less than 1 hour), for those in group 2, comparing ST "fingerprints" during PTCA with ST changes during spontaneous early myocardial infarction (reocclusion in 24 hours) and in group 3, comparing ST "fingerprints" with ST changes during repeat PTCA for restenosis greater than 1 month after the initial PTCA. The ST "fingerprints" among the 20 patients in group 1 were identical in 14 cases (70%) and clearly related in another 4 (20%). Of the 23 patients in group 2, 12 (52%) had the same and 8 (35%) had related patterns. Of 19 patients in group 3, 8 (42% had the same pattern and 8 (42%) had related patterns. Thus, ST fingerprints were the same or clearly related with reocclusion in the same patient from less than 1 hour to greater than 1 month after initial occlusion in 87% of patients overall, in 90% in less than 1 hour, in 87% in less than 24 hours and in 84% greater than 1 month later. Multilead pattern ST-segment "fingerprints" may serve as a noninvasive marker for detecting site-specific reocclusion.

  7. [Qualitative and quantitative diagnostic performance of 320-slice computed tomography for detecting coronary artery disease with respect to atherosclerotic plaque characteristics].

    Science.gov (United States)

    Li, Suhua; Liu, Jinlai; Peng, Long; Dong, Ruimin; Wu, Huilan; Wang, Chenlin; Ni, Qiongqiong; Luo, Yanting; Zhu, Jieming; Chen, Lin

    2014-10-28

    To investigate qualitatively and quantitatively the diagnostic performance of 320-slice CT for detection of coronary artery disease with respect to different atherosclerotic plaque characteristics. A retrospective search was performed for inpatients underwent both coronary CT and further coronary angiography (CAG) from December 1, 2008 to December 31, 2012. The diagnostic performance of 320-slice CTA for detecting significant stenosis ( ≥ 50% diameter) with respect to atherosclerotic plaque characteristics were analyzed by calculating sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, kappa index (κ), and area under the receiver operating characteristic curve (AUC). Chi-square test was used to evaluate whether there were significant differences of the true-case frequency (true positive + true negative) and false-case frequency (false positive + false negative) among groups. Bland-Altman analysis was used to determine limits of agreement between CTA and CAG. A total of 454 patients and 6 779 segments were analyzed. Diagnostic accuracy was higher in non-calcified segments; whereas they decreased in the presence of both mild-moderately and heavily calcified plaques. Excellent agreement (κ = 0.810) between CT and CAG was observed for non-calcified segments, while good agreement was observed for both mild-moderately (κ = 0.701) and heavily calcified segments (κ = 0.750). Both mild-moderate (P = 0.000) and heavy (P = 0.000) calcification decreased the true-case frequency and increased the false-case frequency when compared to non-calcification. There were no significant underestimation or overestimation for non-calcified (P = 0.087) and mild-moderately calcified (P = 0.704) segments, while there was significant overestimation for heavily calcified segments (P = 0.001). Great qualitative and quantitative diagnostic performances of 320-slice CT were observed in non-calcified coronary segments. However, qualitative

  8. Detection of a coronary artery vessel wall: performance of 0.3 mm fine-cell detector computed tomography-a phantom study

    International Nuclear Information System (INIS)

    Yamada, Minoru; Jinzaki, Masahiro; Tanami, Yutaka; Matsumoto, Kazuhiro; Ueno, Akihisa; Kuribayashi, Sachio; Nukui, Masatake; Imai, Yasuhiro; Ishihara, Yotaro; Nishide, Akihiko; Sasaki, Kosuke

    2011-01-01

    The purpose of this study was to evaluate whether experimental fine-cell detector computed tomography with a 0.3125 mm cell (0.3 mm cell CT) can improve the detection of coronary vessel walls compared with conventional 64-slice computed tomography with a 0.625 mm cell (0.6 mm cell CT). A coronary vessel wall phantom was scanned using 0.6 mm cell CT and 0.3 mm cell CT. The data for 0.3 mm cell CT were obtained using four protocols: a radiation dose equal, double, triple or quadruple that were used in the 0.6 mm cell CT protocol. The detectable size of the vessel wall was assessed based on the first and second derivative functions, and the minimum measurable values were compared using a paired t-test. As a result, the minimum detectable wall thickness of 0.6 mm cell CT (1.5 mm) was significantly larger than that of 0.3 mm cell CT performed using the triple- and quadruple-dose protocols (0.9 mm) and the double-dose protocol (1.1 mm). The difference in the minimum detectable vessel wall thickness measured using 0.6 mm cell CT (1.5 ± 0.1 mm) and 0.3 mm cell CT (0.9 ± 0.1 mm, 1.1 ± 0.2 mm) was significant (p < 0.01). We concluded that 0.3 mm cell CT improved the detection of coronary vessel walls when a more than double-dose protocol was used compared with 0.6 mm cell CT.

  9. Detection of von Willebrand factor and tissue factor in platelets-fibrin rich coronary thrombi in acute myocardial infarction.

    Science.gov (United States)

    Yamashita, Atsushi; Sumi, Takahiro; Goto, Shinya; Hoshiba, Yasunari; Nishihira, Kensaku; Kawamoto, Riichirou; Hatakeyama, Kinta; Date, Haruhiko; Imamura, Takuroh; Ogawa, Hisao; Asada, Yujiro

    2006-01-01

    The rapid closure of coronary arteries due to occlusive thrombi is the major cause of acute myocardial infarction. However, the mechanisms of coronary thrombus formation have not been elucidated. We immunohistochemically assessed the localizations and their changes over time of glycoprotein IIb/IIIa, fibrin, von Willebrand factor (vWF), and tissue factor (TF), after the onset of chest pain (platelets, fibrin, vWF, and TF from the early phase of onset, and glycoprotein IIb/IIIa and fibrin were closely associated with vWF and TF, respectively. vWF and/or TF may contribute to occlusive thrombus formation and be novel therapeutic candidates for treating patients with coronary thrombosis.

  10. Multiple giant coronary aneurysms arising from coronary istula to the pulmonary artery revealed in aorta CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun Ju; Lee, Ki Nam [Dept. of Radiology, Dong A University Hospital, Dong-A University College of Medicine, Busan (Korea, Republic of); Lee, Jong Min [Dept. of Radiology, Kyungpook National University Hospital, Kyungpook National University College of Medicine, Daegu (Korea, Republic of)

    2015-12-15

    Coronary fistula is a rare coronary abnormality through which blood drains into the cardiac chamber, great vessel or other vessels. In addition, giant aneurysm arising from coronary fistula is rare pathologic manifestation. Herein, we presented a rare case of multiple giant coronary artery aneurysms arising from coronary to pulmonary artery fistula in a 79-year-old woman presenting with sudden loss of consciousness. The aneurysms were detected using thoracic computed tomography angiography and consequently confirmed by invasive coronary angiography.

  11. Diagnostic value of transmural perfusion ratio derived from dynamic CT-based myocardial perfusion imaging for the detection of haemodynamically relevant coronary artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Coenen, Adriaan; Lubbers, Marisa M.; Dedic, Admir; Chelu, Raluca G.; Geuns, Robert-Jan M. van; Nieman, Koen [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus University Medical Center, Department of Cardiology, Rotterdam (Netherlands); Kurata, Akira; Kono, Atsushi; Dijkshoorn, Marcel L. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Rossi, Alexia [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Barts Health NHS Trust, NIHR Cardiovascular Biomedical Research Unit at Barts, William Harvey Research Institute, Barts and The London School of Medicine and Dentistry, Queen Mary University of London and Department of Cardiology, London (United Kingdom)

    2017-06-15

    To investigate the additional value of transmural perfusion ratio (TPR) in dynamic CT myocardial perfusion imaging for detection of haemodynamically significant coronary artery disease compared with fractional flow reserve (FFR). Subjects with suspected or known coronary artery disease were prospectively included and underwent a CT-MPI examination. From the CT-MPI time-point data absolute myocardial blood flow (MBF) values were temporally resolved using a hybrid deconvolution model. An absolute MBF value was measured in the suspected perfusion defect. TPR was defined as the ratio between the subendocardial and subepicardial MBF. TPR and MBF results were compared with invasive FFR using a threshold of 0.80. Forty-three patients and 94 territories were analysed. The area under the receiver operator curve was larger for MBF (0.78) compared with TPR (0.65, P = 0.026). No significant differences were found in diagnostic classification between MBF and TPR with a territory-based accuracy of 77 % (67-86 %) for MBF compared with 70 % (60-81 %) for TPR. Combined MBF and TPR classification did not improve the diagnostic classification. Dynamic CT-MPI-based transmural perfusion ratio predicts haemodynamically significant coronary artery disease. However, diagnostic performance of dynamic CT-MPI-derived TPR is inferior to quantified MBF and has limited incremental value. (orig.)

  12. 99Tcm-MIBI single photon emission tomography (SPET) for detecting myocardial ischaemia and necrosis in patients with significant coronary artery disease

    International Nuclear Information System (INIS)

    Sciammarella, M.G.; Fragasso, G.; Gerundini, P.; Maffioli, L.; Cappelletti, A.; Margonato, A.; Savi, A.; Chierchia, S.

    1992-01-01

    The ability of 99 Tc m -methoxyisobutylisonitrile (MIBI) single photon emission tomography (SPET) to detect myocardial ischaemia and necrosis was assessed in 56 patients with clinically recognised ischaemic heart disease (IHD). All underwent coronary angiography (CA) and left ventriculography (LV). SPET images were obtained at rest and at peak exercise 90 min after injection of 99 Tc m -MIBI. The presence of persistent (P) or reversible (R) perfusion defects (PD) was then correlated to the resting and exercise ECG and to the results of CA and LV. Of the 56 patients, 34 had reversible underperfusion (RPD), 46 persistent underperfusion (PPD) and 31 had both. The occurrence of RPD correlated well with the occurrence of exercise-induced ST segment depression and/or angina (27 patients of 34 patients, 79%) and with the presence of significant coronary artery disease (CAD) (33 of 44, 73%). In 45 of 46 patients (98%) PPD corresponded to akinetic or severely hypokinetic segments (LV) usually explored by ECG leads exhibiting diagnostic Q waves (42 of 46 patients, 91%). The scan was normal both at rest and after stress in four of 11 patients with no CAD, and in two of 45 patients with CAD. Finally, an abnormal resting scan was seen in seven of 11 patients with normal coronary arteries, of whom six had regional wall motion abnormalities. In conclusion, MIBI SPET is a highly reliable technique for assessing the presence and location of myocardial ischaemia and necrosis. (Author)

  13. [sup 99]Tc[sup m]-MIBI single photon emission tomography (SPET) for detecting myocardial ischaemia and necrosis in patients with significant coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Sciammarella, M.G.; Fragasso, G.; Gerundini, P.; Maffioli, L.; Cappelletti, A.; Margonato, A.; Savi, A.; Chierchia, S. (Istituto Scientifico H San Raffaele, Milan (Italy). Dept. of Nuclear Medicine)

    1992-12-01

    The ability of [sup 99]Tc[sup m]-methoxyisobutylisonitrile (MIBI) single photon emission tomography (SPET) to detect myocardial ischaemia and necrosis was assessed in 56 patients with clinically recognised ischaemic heart disease (IHD). All underwent coronary angiography (CA) and left ventriculography (LV). SPET images were obtained at rest and at peak exercise 90 min after injection of [sup 99]Tc[sup m]-MIBI. The presence of persistent (P) or reversible (R) perfusion defects (PD) was then correlated to the resting and exercise ECG and to the results of CA and LV. Of the 56 patients, 34 had reversible underperfusion (RPD), 46 persistent underperfusion (PPD) and 31 had both. The occurrence of RPD correlated well with the occurrence of exercise-induced ST segment depression and/or angina (27 patients of 34 patients, 79%) and with the presence of significant coronary artery disease (CAD) (33 of 44, 73%). In 45 of 46 patients (98%) PPD corresponded to akinetic or severely hypokinetic segments (LV) usually explored by ECG leads exhibiting diagnostic Q waves (42 of 46 patients, 91%). The scan was normal both at rest and after stress in four of 11 patients with no CAD, and in two of 45 patients with CAD. Finally, an abnormal resting scan was seen in seven of 11 patients with normal coronary arteries, of whom six had regional wall motion abnormalities. In conclusion, MIBI SPET is a highly reliable technique for assessing the presence and location of myocardial ischaemia and necrosis. (Author).

  14. Chronotropic response to vasodilator-stress in patients submitted to myocardial perfusion imaging: impact on the accuracy in detecting coronary stenosis

    International Nuclear Information System (INIS)

    Gimelli, Alessia; Coceani, Michele; Quaranta, Angela; Emdin, Michele; Liga, Riccardo; Marzullo, Paolo

    2015-01-01

    A lower heart rate response (HRR) during vasodilator MPI has been shown to have a relevant adverse prognostic impact. We sought to evaluate the interaction among individual HRR to vasodilator stress and myocardial perfusion imaging (MPI) accuracy in patients with suspected ischemic heart disease (IHD). One hundred and sixty-five consecutive patients were submitted to vasodilator-stress MPI on a cardiac camera equipped with cadmium-zinc-thelluride detectors and coronary angiography. A coronary stenosis >70 % was considered significant. In every patient, the summed difference score (SDS) was computed from MPI images. Patients were categorized according to the tertiles of the distribution of individual HRR during dipyridamole: ''Group 1'' (HRR < 8 bpm; lowest tertile); ''Group 2'' (8 ≤ HRR ≤ 12 bpm; middle tertile); ''Group 3'' (HRR >12 bpm; highest tertile). Significant coronary artery disease (CAD) was present in 102 (62 %) patients. In the overall population, MPI showed a significant accuracy (AUC: 0.81, 95 % CI 0.74-0.86; p < 0.001) in unmasking the presence of significant coronary stenosis. Interestingly, in patients with a blunted HRR during dipyridamole (''Group 1'') MPI showed a significantly lower sensitivity (68 %) in detecting CAD than in those with a higher HRR (''Group 3'') (91 %, p = 0.007), despite a preserved specificity (76 % vs 77 %, P=NS). Similarly, the correlation among CAD extent and post-stress LV functional stunning was limited to ''Group 3'' patients, while it disappeared in those with blunted HRR. In patients with suspected IHD, MPI sensitivity is strongly influenced by the magnitude of patient heart rate increase to the pharmacologic stressor, suggesting an interaction among blunted HRR and lower accuracy in unmasking CAD. (orig.)

  15. Chronotropic response to vasodilator-stress in patients submitted to myocardial perfusion imaging: impact on the accuracy in detecting coronary stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Gimelli, Alessia; Coceani, Michele; Quaranta, Angela; Emdin, Michele [Fondazione Toscana Gabriele Monasterio, Pisa (Italy); Liga, Riccardo [University Hospital of Pisa, Cardio-Thoracic and Vascular Department, Pisa (Italy); Marzullo, Paolo [Fondazione Toscana Gabriele Monasterio, Pisa (Italy); CNR, Institute of Clinical Physiology, Pisa (Italy)

    2015-11-15

    A lower heart rate response (HRR) during vasodilator MPI has been shown to have a relevant adverse prognostic impact. We sought to evaluate the interaction among individual HRR to vasodilator stress and myocardial perfusion imaging (MPI) accuracy in patients with suspected ischemic heart disease (IHD). One hundred and sixty-five consecutive patients were submitted to vasodilator-stress MPI on a cardiac camera equipped with cadmium-zinc-thelluride detectors and coronary angiography. A coronary stenosis >70 % was considered significant. In every patient, the summed difference score (SDS) was computed from MPI images. Patients were categorized according to the tertiles of the distribution of individual HRR during dipyridamole: ''Group 1'' (HRR < 8 bpm; lowest tertile); ''Group 2'' (8 ≤ HRR ≤ 12 bpm; middle tertile); ''Group 3'' (HRR >12 bpm; highest tertile). Significant coronary artery disease (CAD) was present in 102 (62 %) patients. In the overall population, MPI showed a significant accuracy (AUC: 0.81, 95 % CI 0.74-0.86; p < 0.001) in unmasking the presence of significant coronary stenosis. Interestingly, in patients with a blunted HRR during dipyridamole (''Group 1'') MPI showed a significantly lower sensitivity (68 %) in detecting CAD than in those with a higher HRR (''Group 3'') (91 %, p = 0.007), despite a preserved specificity (76 % vs 77 %, P=NS). Similarly, the correlation among CAD extent and post-stress LV functional stunning was limited to ''Group 3'' patients, while it disappeared in those with blunted HRR. In patients with suspected IHD, MPI sensitivity is strongly influenced by the magnitude of patient heart rate increase to the pharmacologic stressor, suggesting an interaction among blunted HRR and lower accuracy in unmasking CAD. (orig.)

  16. ST Elevation Infarction after Heart Transplantation Induced by Coronary Spasms and Mural Thrombus Detected by Optical Coherence Tomography

    DEFF Research Database (Denmark)

    Clemmensen, Tor Skibsted; Holm, Niels Ramsing; Eiskjær, Hans

    2016-01-01

    The case illustrates the possible link between coronary spasms, intraluminal thrombus formation, and widespread organized and layered thrombi in HTx patients. Furthermore, the case underlines the clinical value of OCT as a novel method for high-resolution vessel imaging in heart-transplanted (HTx...

  17. The Significance of Carotid Artery Plaques in the Detection of Coronary Artery Disease in Asymptomatic Type 2 Diabetic Patients

    Czech Academy of Sciences Publication Activity Database

    Charvát, J.; Michalová, K.; Chlumský, J.; Horáčková, M.; Valenta, Zdeněk; Žďárská, D.

    2006-01-01

    Roč. 34, č. 1 (2006), s. 13-20 ISSN 0300-0605 Institutional research plan: CEZ:AV0Z10300504 Keywords : coronary heart disease * type 2 diabetes mellitus * stress myocardial SPECT * selective coronarography Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.665, year: 2006

  18. New modalities of ultrasound-based intima-media thickness, arterial stiffness and non-coronary vascular calcifications detection to assess cardiovascular risk.

    Science.gov (United States)

    Flore, R; Ponziani, F R; Tinelli, G; Arena, V; Fonnesu, C; Nesci, A; Santoro, L; Tondi, P; Santoliquido, A

    2015-04-01

    Carotid intima-media thickness (c-IMT), arterial stiffness (AS) and vascular calcification (VC) are now considered important new markers of atherosclerosis and have been associated with increased prevalence of cardiovascular events. An accurate, reproducible and easy detection of these parameters could increase the prognostic value of the traditional cardiovascular risk factors in many subjects at low and intermediate risk. Today, c-IMT and AS can be measured by ultrasound, while cardiac computed tomography is the gold standard to quantify coronary VC, although concern about the reproducibility of the former and the safety of the latter have been raised. Nevertheless, a safe and reliable method to quantify non-coronary (i.e., peripheral) VC has not been detected yet. To review the most innovative and accurate ultrasound-based modalities of c-IMT and AS detection and to describe a novel UltraSound-Based Carotid, Aortic and Lower limbs Calcification Score (USB-CALCs, simply named CALC), allowing to quantify peripheral calcifications. Finally, to propose a system for cardiovascular risk reclassification derived from the global evaluation of "Quality Intima-Media Thickness", "Quality Arterial Stiffness", and "CALC score" in addition to the Framingham score.

  19. Detection of diminished response to cold pressor test in smokers: assessment using phase-contrast cine magnetic resonance imaging of the coronary sinus.

    Science.gov (United States)

    Kato, Shingo; Kitagawa, Kakuya; Yoon, Yeonyee E; Nakajima, Hiroshi; Nagata, Motonori; Takase, Shinichi; Nakamori, Shiro; Ito, Masaaki; Sakuma, Hajime

    2014-04-01

    The purposes of this study were to evaluate the reproducibility for measuring the cold pressor test (CPT)-induced myocardial blood flow (MBF) alteration using phase-contrast (PC) cine MRI, and to determine if this approach could detect altered MBF response to CPT in smokers. After obtaining informed consent, ten healthy male non-smokers (mean age: 28±5 years) and ten age-matched male smokers (smoking duration ≥5 years, mean age: 28±3 years) were examined in this institutional review board approved study. Breath-hold PC cine MR images of the coronary sinus were obtained with a 3T MR imager with 32 channel coils at rest and during a CPT performed after immersing one foot in ice water. MBF was calculated as coronary sinus flow divided by the left ventricular (LV) mass which was given as a total LV myocardial volume measured on cine MRI multiplied by the specific gravity (1.05 g/mL). In non-smokers, MBF was 0.86±0.25 mL/min/g at rest, with a significant increase to 1.20±0.36 mL/min/g seen during CPT (percentage change of MBF (∆MBF (%)); 39.2%±14.4%, psmokers and non-smokers for resting MBF (0.85±0.32 mL/min/g, p=0.91). However, ∆MBF (%) in smokers was significantly reduced (-4.0±32.2% vs. 39.2±14.4%, p=0.011). PC cine MRI can be used to reproducibly quantify MBF response to CPT and to detect impaired flow response in smokers. This MR approach may be useful for monitoring the sequential change of coronary blood flow in various potentially pathologic conditions and for investigating its relationship with cardiovascular risk. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. A comparative study between TL-201 SPECT myocardial perfusion scintigraphy and dobutamine stress echocardiography in the detection of coronary artery disease at the Philippine Heart Center

    International Nuclear Information System (INIS)

    Ogbac, R.V.; Martinez, A.O.; Obaldo, J.M.; Monzon, O.P.; Torres, J.F.; Rondilla, L.W.S.; Yap, J.S.; Flores, V.B.; Santos, R.J.; Jara, R.D.

    1996-01-01

    Although thallium-201 SPECT myocardial perfusion scintigraphy (MPS) has shown considerable accuracy for the detection of coronary artery disease (CAD), dobutamine stress echocardiography (DSE), a relatively new method for the detection of CAD had been recently utilized at the Philippine Heart Center. To assess its diagnostic worth versus that of thallium-201 spect myocardial scintigraphy (MPS), we studied 18 patients who underwent both procedures. Coronary angiography (CA) was used as the gold standard. MPS was performed with maximal treadmill exercise or with dipyridamole (0.568 mg/kg over 4 minutes) and Tl-201 was injected at peak stress. DSE was performed by infusing dobutamine at an increment of 5 μg/kg/min up to a maximum of 40. Atropine (0.01%) was added when 85% of maximum predicted heart rate is not achieved. Significant stenosis (>70%) was found in 16 out of 18 patients by CA. The sensitivity for the presence of CAD was 88% (14/16) and 69% (11/16) for MPS and DSE respectively. Specificity was 100% (2/2) for both. PPV was 100% for both while NPV was 50% and 29% for MPS and DSE respectively. Diagnostic accuracies were 89% and 72% for MPS and DSE respectively (P>0.05). Sensitivity for detecting left anterior descending artery (LAD) lesion was 71% 64% for MPS and DSE respectively; specificity was 75% and 100% respectively. For the left circumplex artery (LCX) lesion, both MPS and DSE had a sensitivity of 62% and specificity of 60%. Likewise for the right coronary artery (RCA) lesion, both had a sensitivity of 66% and specificity of 50%. Diagnostic accuracies were equal for both tests at 72% for LAD; 61% for LCX; and 61% for RCA. Kappa tests for association shows ρ values of >0.05 for overall and individual CAD detection suggesting no significant difference between MPS and DSE. Although there is a trend showing better detection of CAD with MPS, this particular study shows that both tests are comparable with regards to detection of the presence of CAD and of

  1. Comparison of adenosine and treadmill exercise thallium-201 stress tests for the detection of coronary artery disease

    International Nuclear Information System (INIS)

    Abe, Shinya; Takeishi, Yasuchika; Chiba, Junya; Ikeda, Kozue; Tomoike, Hitonobu

    1993-01-01

    To determine the clinical usefulness of adenosine Tl-201 imaging for the evaluation of coronary artery disease, 22 patients with suspected coronary artery disease who underwent adenosine and exercise Tl-201 single photon emission computed tomography (SPECT) were studied. The peak levels of heart rate (83 vs 123 bpm, p<0.001), systolic blood pressure (124 vs 164 mmHg, p<0.001), diastolic blood pressure (70 vs 86 mmHg, p<0.01) and rate pressure products (10220 vs 20410 bpm x mmHg, p<0.001) were markedly smaller during adenosine infusion than during exercise. Segmental agreements between adenosine and exercise tests were 90% (218 of 242 segments) regarding the presence of perfusion defects and 89% (215 of 242 segments) regarding the presence of redistribution. Regional Tl-201 uptake (r=0.85, p<0.001) and the extent (r=0.75, p<0.001) and intensity (r=0.83, p<0.001) of Tl-201 defects during adenosine testing were closely correlated with those of exercise testing. Adenosine and exercise tests showed similar sensitivities for the identification of individual coronary stenosis (85% vs 78%). However, in patients who were unable to perform adequate exercise (maximal heart rate<120 bpm), the sensitivity of adenosine imaging tended to be higher than that of exercise imaging (92% vs 69%, p=0.07). Adenosine Tl-201 imaging is an alternative to the exercise test for assessing the severity and loci of coronary artery disease, especially in patients who are unable to perform adequate physical exercise. (author)

  2. Use of multivariate analysis to improve the accuracy of radionuclide angiography with stress in detecting coronary artery disease in men

    International Nuclear Information System (INIS)

    Greenberg, P.S.; Bible, M.; Ellestad, M.H.; Berge, R.; Johnson, K.; Hayes, M.

    1983-01-01

    A multivariate analysis (MVA) system was derived retrospectively from a population of 76 males with coronary artery disease and 18 control subjects. Posterior probabilities were then derived from such a system prospectively in a new male population of 11 subjects with normal coronary arteries and hemodynamics and 63 patients with coronary artery disease. The sensitivity was 84% compared to that for change in ejection fraction (delta EF) greater than or equal to 5 criterion of 71% (p less than 0.01), the specificity was 91% compared to 73% for the delta EF greater than or equal to 5 criterion (p greater than 0.05), and the correct classification rate was 85% compared to 72% for the delta EF greater than or equal to 5 criterion (p less than 0.01). The significant variables were: change in EF with exercise, percent maximal heart rate, change in end-diastolic volume (delta EDV) with exercise, change in R wave, and exercise duration. Application of the multivariate approach to radionuclide imaging with stress, including both exercise and nuclear parameters, significantly improved the diagnostic accuracy of the test and allowed for a probability statement concerning the likelihood of disease

  3. Value of heart-lung ratio of 99Tcm N-NOET in detection of coronary artery disease

    International Nuclear Information System (INIS)

    Zhang Wanchun; Li Sijin; Liu Jianzhong; Hu Guang; Wang Jin; Lv Jiyuan

    2005-01-01

    To investigate the relationship between the heart-lung ratio (HLR) assessed with exercise 99 Tc m N-NOET myocardial perfusion imaging and coronary artery disease (CAD), 10 normal volunteers (7 male and 3 female, aged 40.0 ± 5.8 years), and 40 suspected CAD patients (21 male and 19 female, aged 55.2 ± 8.5 years) underwent exercise (30 min)-delayed (2 and 4 h postinjection) 99 Tc m -NOET gated myocardial perfusion imaging, and the HLR at different time was calculated. 13 patients among them took the coronary angiography in two months. According to the exercise heart-lung ratio (EXHLR), 50 subjects were divided into two groups. G1(n=36, EXHLR≥2) included 10 normal volunteers, 5 patients with normal coronary arteries, and the rest 21 patients had no relevant symptom and cardiac event in the follow-up period of 4 to 12 months. The image was normal in all of the subjects in G1. In G2 (n=14, EXHLR 99 Tc m N-NOET may be useful as a diagnostic index in CAD because it is more sensitive than myocardial perfusion imaging. (authors)

  4. Diagnostic accuracy of magnetic resonance angiography for detection of coronary artery disease: a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Di Leo, Giovanni [IRCCS Policlinico San Donato, Radiology Unit, San Donato Milanese (Italy); Fisci, Erica [Universita degli Studi di Genova, Scuola di Specializzazione in Radiodiagnostica, Genova (Italy); Secchi, Francesco [IRCCS Policlinico San Donato, Radiology Unit, San Donato Milanese (Italy); Universita degli Studi di Milano, PhD Course in Integrative Biomedical Research, Milan (Italy); Ali, Marco [Universita degli Studi di Milano, PhD Course in Integrative Biomedical Research, Milan (Italy); Ambrogi, Federico [Universita degli Studi di Milano, Department of Clinical Sciences and Community Health, Milan (Italy); Sconfienza, Luca Maria; Sardanelli, Francesco [IRCCS Policlinico San Donato, Radiology Unit, San Donato Milanese (Italy); Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, San Donato Milanese (Italy)

    2016-10-15

    To review the diagnostic performance of MR coronary angiography (MRCA) for coronary artery disease (CAD). Two independent reviewers searched on MEDLINE/EMBASE with the following inclusion criteria: 01/01/2000-03/23/2015 publication date; per-patient sensitivity/specificity for >50 % stenosis confirmed by conventional coronary angiography with raw data provided or retrievable; sample size >10. Quality was appraised using QUADAS2. Nine hundred eighteen studies were retrieved, 24 of them, including 1,638 patients, were selected. Using a bivariate model, the pooled sensitivity was 89 % (95 % confidence interval 86-92 %), the pooled specificity 72 % (63-79 %). Meta-regression did not show a significant impact on sensitivity/specificity for both year of publication and disease prevalence (p ≥ 0.114). Sensitivity of contrast-enhanced examinations (95 %, 90-97 %) was higher (p = 0.005) than that of unenhanced examinations (87 %, 83-90 %). Specificity of whole-heart acquisition mode (78 %, 72-84 %) was higher (p = 0.006) than that of targeted mode (57 %, 45-69 %). Specificity at 3 T (83 %, 69-92 %) was higher (p = 0.067) than that at 1.5 T (68 %, 60-76 %). Risk of bias and concerns regarding applicability were low. Sensitivity and specificity of MRCA for CAD were 89 % and 72 %, respectively. A specificity higher than 80 % may be obtained at 3 T. Whole-heart contrast-enhanced protocols should be preferred for a higher diagnostic performance. (orig.)

  5. Diagnostic accuracy of magnetic resonance angiography for detection of coronary artery disease: a systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Di Leo, Giovanni; Fisci, Erica; Secchi, Francesco; Ali, Marco; Ambrogi, Federico; Sconfienza, Luca Maria; Sardanelli, Francesco

    2016-01-01

    To review the diagnostic performance of MR coronary angiography (MRCA) for coronary artery disease (CAD). Two independent reviewers searched on MEDLINE/EMBASE with the following inclusion criteria: 01/01/2000-03/23/2015 publication date; per-patient sensitivity/specificity for >50 % stenosis confirmed by conventional coronary angiography with raw data provided or retrievable; sample size >10. Quality was appraised using QUADAS2. Nine hundred eighteen studies were retrieved, 24 of them, including 1,638 patients, were selected. Using a bivariate model, the pooled sensitivity was 89 % (95 % confidence interval 86-92 %), the pooled specificity 72 % (63-79 %). Meta-regression did not show a significant impact on sensitivity/specificity for both year of publication and disease prevalence (p ≥ 0.114). Sensitivity of contrast-enhanced examinations (95 %, 90-97 %) was higher (p = 0.005) than that of unenhanced examinations (87 %, 83-90 %). Specificity of whole-heart acquisition mode (78 %, 72-84 %) was higher (p = 0.006) than that of targeted mode (57 %, 45-69 %). Specificity at 3 T (83 %, 69-92 %) was higher (p = 0.067) than that at 1.5 T (68 %, 60-76 %). Risk of bias and concerns regarding applicability were low. Sensitivity and specificity of MRCA for CAD were 89 % and 72 %, respectively. A specificity higher than 80 % may be obtained at 3 T. Whole-heart contrast-enhanced protocols should be preferred for a higher diagnostic performance. (orig.)

  6. Coronary artery with aberrant origin malignant right

    International Nuclear Information System (INIS)

    Ozcan, E.; Bozlar, U.; Demirkol, S.; Saglam, M.

    2012-01-01

    Full text: Introduction: Congenital anomalies of the coronary arteries is a major cause of sudden death, especially in young patients. Objectives and tasks: In this study we aim to present a young patient with chest pain who had malignant right coronary artery (RCA) with aberrant origin. Materials and methods: 24-year-old man who applied cardiology clinic for chest pain and palpitations especially after exercise, was referred to our clinic for coronary computed tomography (CT) angiography to evaluate coronary artery anomalies. Results: In CT angiography; we detected aberrant RCA with origin of tubularly part of ascendant aorta with a malignant course between aorta and pulmonary artery. Left main coronary artery, left anterior descending and circumflex artery had normal origin and course. Conclusion: Coronary artery with malignant course may cause sudden death especially after exercise. Coronary CT angiography has an important role in diagnosis of congenital coronary artery anomalies, with high resolution multiplanner reformatted images

  7. Diagnostic power of longitudinal strain at rest for the detection of obstructive coronary artery disease in patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Zuo, Houjuan; Yan, Jiangtao; Zeng, Hesong; Li, Wenyu; Li, Pengcheng; Liu, Zhengxiang; Cui, Guanglin; Lv, Jiagao; Wang, Daowen; Wang, Hong

    2015-01-01

    Global longitudinal strain (GLS) measured by 2-D speckle-tracking echocardiography (2-D STE) at rest has been recognized as a sensitive parameter in the detection of significant coronary artery disease (CAD). However, the diagnostic power of 2-D STE in the detection of significant CAD in patients with diabetes mellitus is unknown. Two-dimensional STE features were studied in total of 143 consecutive patients who underwent echocardiography and coronary angiography. Left ventricular global and segmental peak systolic longitudinal strains (PSLSs) were quantified by speckle-tracking imaging. In the presence of obstructive CAD (defined as stenosis ≥75%), global PSLS was significantly lower in patients with diabetes mellitus than in patients without (16.65 ± 2.29% vs. 17.32 ± 2.27%, p diabetes mellitus (cutoff value: -18.35%, sensitivity: 78.8%, specificity: 77.5%). However, global PSLS could detect obstructive CAD in diabetic patients at a lower cutoff value with inadequate sensitivity and specificity (cutoff value: -17.15%; sensitivity: 61.1%, specificity: 52.9%). In addition, the results for segmental PSLS were similar to those for global PSLS. In conclusion, global and segmental PSLSs at rest were significantly lower in patients with both obstructive CAD and diabetes mellitus than in patients with obstructive CAD only; thus, PSLSs at rest might not be a useful parameter in the detection of obstructive CAD in patients with diabetes mellitus. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. Altered coronary endothelial function in young smokers detected by magnetic resonance assessment of myocardial blood flow during the cold pressor test.

    Science.gov (United States)

    Ichikawa, Yasutaka; Kitagawa, Kakuya; Kato, Shingo; Dohi, Kaoru; Hirano, Tadanori; Ito, Masaaki; Sakuma, Hajime

    2014-06-01

    Endothelial dysfunction is a key element in early atherogenesis. The purposes of this study were to evaluate the feasibility of magnetic resonance (MR) assessment of altered myocardial blood flow (MBF) in response to the cold pressor test (CPT) and to determine if coronary endothelial dysfunction in young smokers can be detected with this noninvasive approach. Fourteen healthy non-smokers (31 ± 6 years) and 12 smokers (34 ± 8 years) were studied. Breath-hold phase-contrast cine MR imaging (PC-MRI) of the coronary sinus (CS) were obtained at rest and during the CPT. MBF was measured as CS flow divided by left ventricle mass and the rate pressure product. In non-smokers, MBF was 0.88 ± 0.19 ml/min/g at rest and significantly increased to 1.13 ± 0.26 ml/min/g during the CPT (P = 0.0001). In smokers, MBF was 0.94 ± 0.26 ml/min/g at rest and 0.96 ± 0.30 ml/min/g during the CPT (P = 0.73). ΔMBF (MBF during the CPT-MBF at rest) was significantly reduced in smokers compared with non-smokers (0.02 ± 0.20 vs. 0.26 ± 0.18 ml/min/g, P = 0.005). The intra-class correlation coefficient between measurements by two observers was 0.90 for ΔMBF. A significant reduction in MBF response to CPT was demonstrated in young smokers with PC-MRI at 1.5 T. This noninvasive method has great potential for assessment of coronary endothelial function.

  9. 99Tcm-MIBI single photon emission tomography (SPET) for detecting myocardial ischaemia and necrosis in patients with significant coronary artery disease.

    Science.gov (United States)

    Sciammarella, M G; Fragasso, G; Gerundini, P; Maffioli, L; Cappelletti, A; Margonato, A; Savi, A; Chierchia, S

    1992-12-01

    The ability of 99Tcm-methoxyisobutylisonitrile (MIBI) single photon emission tomography (SPET) to detect myocardial ischaemia and necrosis was assessed in 56 patients (45 male, 11 female, aged 55 +/- 5 years), with clinically recognized ischaemic heart disease (IHD). All underwent coronary angiography (CA) and left ventriculography (LV). SPET images were obtained at rest and at peak exercise (Modified Bruce) 90 min after injection of 99Tcm-MIBI (650-850 MBq). Data were acquired in 30 min over 180 degrees (from 45 degrees RAO to 45 degrees LPO) with no correction for attenuation, using a 64 x 64 matrix. The presence of persistent (P) or reversible (R) perfusion defects (PD) was then correlated to the resting and exercise ECG and to the results of CA and LV. Of the 56 patients, 34 had reversible underperfusion (RPD), 46 persistent underperfusion (PPD) and 31 had both. The occurrence of RPD correlated well with the occurrence of exercise-induced ST segment depression and/or angina (27 patients of 34 patients, 79%) and with the presence of significant coronary artery disease (CAD) (33 of 44, 73%). In 45 of 46 patients (98%) PPD corresponded to akinetic or severely hypokinetic segments (LV) usually explored by ECG leads exhibiting diagnostic Q waves (42 of 46 patients, 91%). The scan was normal both at rest and after stress in four of 11 patients with no CAD, and in two of 45 patients with CAD. Finally, an abnormal resting scan was seen in seven of 11 patients with normal coronary arteries, of whom six had regional wall motion abnormalities.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. [Coronary angioplasty with the Monorail system via 6 French diagnostic catheters].

    Science.gov (United States)

    Villavicencio, R; González, H; López, J; Zavala, E; Ban Hayashi, E B; Gaspar, J; Gil, M; Martínez Ríos, M A

    1994-01-01

    We studied the use of "Monorail" system with Express (Scimed) balloon catheters for coronary angioplasty through 6 French (F) "high-flow" diagnostic catheters (Novoste, USCI). Prospectively, from July 1992 to January 1993, angioplasty of 31 lesions in 24 patients was attempted (1.3 lesions/procedure). Twenty procedures were of a single lesion and four were multi-vessel angioplasty. Fourteen lesions were in the left anterior descending or in its branches, 10 in the left circumflex or in its branches, 6 in the right coronary artery, and one in the distal anastomosis of an internal mammary artery graft. Thirteen lesions (42%) were type A, 17 (55%) type B and one (3%) type C. Balloon sizes varied between 2.0 and 3.5 mm. Twenty-nine lesions could be successfully dilated (93.5%); two cases were unsuccessful due to an acute occlusion in one and residual stenosis of more than 50% in the other. For only one case, another balloon catheter different from the "Monorail" system was necessary to complete a multi-vessel angioplasty. Coronary visualization and manipulation of the balloon through the tip of the diagnostic catheter were satisfactory in all cases, except with the 3.5 mm balloon catheter. Coronary angioplasty with "Monorail" system balloon catheters through 6 F "high-flow" diagnostic catheters is feasible and provides a high success rate in simple and moderately complex selected lesions, including multivessel angioplasty with advantages of smaller artery punction and the feasibility of performing coronary angioplasty with the same catheter used for diagnostic angiography.

  11. Feasibility of an automatic computer-assisted algorithm for the detection of significant coronary artery disease in patients presenting with acute chest pain

    International Nuclear Information System (INIS)

    Kang, Ki-Woon; Chang, Hyuk-Jae; Shim, Hackjoon; Kim, Young-Jin; Choi, Byoung-Wook; Yang, Woo-In; Shim, Jee-Young; Ha, Jongwon; Chung, Namsik

    2012-01-01

    Automatic computer-assisted detection (auto-CAD) of significant coronary artery disease (CAD) in coronary computed tomography angiography (cCTA) has been shown to have relatively high accuracy. However, to date, scarce data are available regarding the performance of auto-CAD in the setting of acute chest pain. This study sought to demonstrate the feasibility of an auto-CAD algorithm for cCTA in patients presenting with acute chest pain. We retrospectively investigated 398 consecutive patients (229 male, mean age 50 ± 21 years) who had acute chest pain and underwent cCTA between Apr 2007 and Jan 2011 in the emergency department (ED). All cCTA data were analyzed using an auto-CAD algorithm for the detection of >50% CAD on cCTA. The accuracy of auto-CAD was compared with the formal radiology report. In 380 of 398 patients (18 were excluded due to failure of data processing), per-patient analysis of auto-CAD revealed the following: sensitivity 94%, specificity 63%, positive predictive value (PPV) 76%, and negative predictive value (NPV) 89%. After the exclusion of 37 cases that were interpreted as invalid by the auto-CAD algorithm, the NPV was further increased up to 97%, considering the false-negative cases in the formal radiology report, and was confirmed by subsequent invasive angiogram during the index visit. We successfully demonstrated the high accuracy of an auto-CAD algorithm, compared with the formal radiology report, for the detection of >50% CAD on cCTA in the setting of acute chest pain. The auto-CAD algorithm can be used to facilitate the decision-making process in the ED.

  12. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    International Nuclear Information System (INIS)

    Hacker, M.; Hack, N.; Tiling, R.; Jakobs, T.; Nikolaou, K.; Becker, C.; Ziegler, F. von; Knez, A.; Koenig, A.; Klauss, V.

    2007-01-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 ± 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  13. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, M.; Hack, N.; Tiling, R. [Klinikum Grosshadern (Germany). Dept. of Nuclear Medicine; Jakobs, T.; Nikolaou, K.; Becker, C. [Klinikum Grosshadern (Germany). Dept. of Clinical Radiology; Ziegler, F. von; Knez, A. [Klinikum Grosshadern (Germany). Dept. of Cardiology; Koenig, A.; Klauss, V. [Medizinische Poliklinik-Innenstadt, Univ. of Munich (Germany). Dept. of Cardiology

    2007-07-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting ''obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 {+-} 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  14. Immuno-Spin Trapping-Based Detection of Oxidative Modifications in Cardiomyocytes and Coronary Endothelium in the Progression of Heart Failure in Tgαq*44 Mice

    Directory of Open Access Journals (Sweden)

    Bartosz Proniewski

    2018-05-01

    Full Text Available Recent studies suggest both beneficial and detrimental role of increased reactive oxygen species and oxidative stress in heart failure (HF. However, it is not clear at which stage oxidative stress and oxidative modifications occur in the endothelium in relation to cardiomyocytes in non-ischemic HF. Furthermore, most methods used to date to study oxidative stress are either non-specific or require tissue homogenization. In this study, we used immuno-spin trapping (IST technique with fluorescent microscopy-based detection of DMPO nitrone adducts to localize and quantify oxidative modifications of the hearts from Tgαq*44 mice; a murine model of HF driven by cardiomyocyte-specific overexpression of Gαq* protein. Tgαq*44 mice and age-matched FVB controls at early, transition, and late stages of HF progression were injected with DMPO in vivo and analyzed ex vivo for DMPO nitrone adducts signals. Progressive oxidative modifications in cardiomyocytes, as evidenced by the elevation of DMPO nitrone adducts, were detected in hearts from 10- to 16-month-old, but not in 8-month-old Tgαq*44 mice, as compared with age-matched FVB mice. The DMPO nitrone adducts were detected in left and right ventricle, septum, and papillary muscle. Surprisingly, significant elevation of DMPO nitrone adducts was also present in the coronary endothelium both in large arteries and in microcirculation simultaneously, as in cardiomyocytes, starting from 10-month-old Tgαq*44 mice. On the other hand, superoxide production in heart homogenates was elevated already in 6-month-old Tgαq*44 mice and progressively increased to high levels in 14-month-old Tgαq*44 mice, while the enzymatic activity of catalase, glutathione reductase, and glutathione peroxidase was all elevated as early as in 4-month-old Tgαq*44 mice and stayed at a similar level in 14-month-old Tgαq*44. In summary, this study demonstrates that IST represents a unique method that allows to quantify oxidative

  15. Prognostic importance of silent myocardial ischemia detected by intravenous dipyridamole thallium myocardial imaging in asymptomatic patients with coronary artery disease

    International Nuclear Information System (INIS)

    Younis, L.T.; Byers, S.; Shaw, L.; Barth, G.; Goodgold, H.; Chaitman, B.R.

    1989-01-01

    One hundred seven asymptomatic patients who underwent intravenous dipyridamole thallium imaging were evaluated to determine prognostic indicators of subsequent cardiac events over an average follow-up period of 14 +/- 10 months. Univariate analysis of 18 clinical, scintigraphic and angiographic variables revealed that a reversible thallium defect, a combined fixed and reversible thallium defect, number of segmental thallium defects and extent of coronary artery disease were significant predictors of subsequent cardiac events. Of the 13 patients who died or had a nonfatal infarction, 12 had a reversible thallium defect. Stepwise logistic regression analysis selected a reversible thallium defect as the only significant predictor of cardiac events. When death or myocardial infarction was the outcome variable, a combined fixed and reversible thallium defect was the only predictor of outcome. In patients without previous myocardial infarction, the cardiac event rate was significantly greater in those with an abnormal versus normal thallium scan (55% versus 12%, p less than 0.001). Thus, intravenous dipyridamole thallium scintigraphy is a useful noninvasive test to risk stratify asymptomatic patients with coronary artery disease. A reversible thallium defect most likely indicates silent myocardial ischemia in a sizable fraction of patients in this clinical subset and is associated with an unfavorable prognosis

  16. Serial thallium-201 myocardial imaging after dipyridamole infusion: diagnostic utility in detecting coronary stenoses and relationship to regional wall motion

    International Nuclear Information System (INIS)

    Leppo, J.; Boucher, C.A.; Okada, R.D.; Newell, J.B.; Strauss, H.W.; Pohost, G.M.

    1982-01-01

    After a 4-minute i.v. dipyridamole infusion, 0.14 mg/kg/min, serial thallium-201 scans were obtained in 60 patients undergoing cardia catheterization. Forty patients had significant (greater than or equal to50% stenosis) coronary artery disease (CAD), and 20 patients had normal coronary arteries or trivial lesions. The images were graded qualitatively for thallium activity by three observers. Sensitivity was 93% (37 of 40) and specificity was 80% (16 of 20). The sensitivity and specificity of the thallium-201 study were not affected by the extent of CAD, the presence of Q waves, or propranolol therapy. Twenty-seven of 37 patients who had initial defects (73%) had complete thallium redistribution of one or more defects. Patient-by-patient anlaysis using a regression model of all patients showed that the fate of a segmental thallium defect predicted abnormal wall motion by angiography better than ECG Q waves. The presence of propranolol therapy or collaterals did not significantly affect the thallium redistribution results. It is concluded that qualitative interpretation by multiple observers of thallium images after dipyridamole infusion is a highly sensitive and specific test for CAD. After dipyridamole, as with exercise stress, the extent of thallium redistribution is related to the degree of myocardial wall motion abnormality

  17. Meta-analysis: diagnostic accuracy of coronary CT angiography with prospective ECG gating based on step-and-shoot, Flash and volume modes for detection of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Linfeng; Zhou, Tao; Zhang, Ruijie; Peng, Zhaohui; Ding, Juan; Wang, Sen; Li, Min; Sun, Gang [Jinan Military General Hospital, Department of Medical Imaging, Jinan, Shandong Province (China); Xu, Lin [Jinan Military General Hospital, Department of Medical Cardiology, Jinan, Shandong Province (China)

    2014-10-15

    To investigate the diagnostic performance of coronary computed tomographic angiography (CCTA) with prospective electrocardiograph (ECG) gating based on step-and-shoot (SAS), Flash and volume imaging modes. We searched the electronic databases PubMed for all published studies regarding CCTA. We used an exact binomial rendition of the bivariate mixed-effects regression model developed for synthesis of diagnostic data. A total of 21,852 segments, 4,851 vessels and 1,375 patients were identified using database searches. Patient-level pooled sensitivity was 0.99 (95 % confidence interval [CI], 0.98-1.00); specificity was 0.88 (CI, 0.85-0.91). The results showed that the sensitivity and specificity for detection of significant stenosis did not differ in the three protocols (P = 0.24). No heterogeneity was found at the patient level for sensitivity (Q = 26.23; P = 0.12; I {sup 2} = 27.56 % [CI, 0.00-67.02 %]) and specificity (Q = 19.54; P = 0.42; I {sup 2} = 2.78 % [CI, 0.00-66.26 %]). CCTA with prospective ECG gating has similar high diagnostic value to rule out CAD in all three presented modes. (orig.)

  18. Management of coronary artery disease

    Science.gov (United States)

    Safri, Z.

    2018-03-01

    Coronary Artery Disease (CAD) is associated with significant morbidity and mortality, therefore it’s important to early and accurate detection and appropriate management. Diagnosis of CAD include clinical examination, noninvasive techniques such as biochemical testing, a resting ECG, possibly ambulatory ECG monitoring, resting echocardiography, chest X-ray in selected patients; and catheterization. Managements of CAD patients include lifestyle modification, control of CAD risk factors, pharmacologic therapy, and patient education. Revascularization consists of percutaneous coronary angioplasty and coronary artery bypass grafting. Cardiac rehabilitation should be considered in all patients with CAD. This comprehensive review highlights strategies of management in patients with CAD.

  19. Improved Accuracy of Myocardial Perfusion SPECT for the Detection of Coronary Artery Disease by Utilizing a Support Vector Machines Algorithm

    Science.gov (United States)

    Arsanjani, Reza; Xu, Yuan; Dey, Damini; Fish, Matthews; Dorbala, Sharmila; Hayes, Sean; Berman, Daniel; Germano, Guido; Slomka, Piotr

    2012-01-01

    We aimed to improve the diagnostic accuracy of automatic myocardial perfusion SPECT (MPS) interpretation analysis for prediction of coronary artery disease (CAD) by integrating several quantitative perfusion and functional variables for non-corrected (NC) data by support vector machines (SVM), a computer method for machine learning. Methods 957 rest/stress 99mtechnetium gated MPS NC studies from 623 consecutive patients with correlating invasive coronary angiography and 334 with low likelihood of CAD (LLK < 5% ) were assessed. Patients with stenosis ≥ 50% in left main or ≥ 70% in all other vessels were considered abnormal. Total perfusion deficit (TPD) was computed automatically. In addition, ischemic changes (ISCH) and ejection fraction changes (EFC) between stress and rest were derived by quantitative software. The SVM was trained using a group of 125 pts (25 LLK, 25 0-, 25 1-, 25 2- and 25 3-vessel CAD) using above quantitative variables and second order polynomial fitting. The remaining patients (N = 832) were categorized based on probability estimates, with CAD defined as (probability estimate ≥ 0.50). The diagnostic accuracy of SVM was also compared to visual segmental scoring by two experienced readers. Results Sensitivity of SVM (84%) was significantly better than ISCH (75%, p < 0.05) and EFC (31%, p < 0.05). Specificity of SVM (88%) was significantly better than that of TPD (78%, p < 0.05) and EFC (77%, p < 0.05). Diagnostic accuracy of SVM (86%) was significantly better than TPD (81%), ISCH (81%), or EFC (46%) (p < 0.05 for all). The Receiver-operator-characteristic area-under-the-curve (ROC-AUC) for SVM (0.92) was significantly better than TPD (0.90), ISCH (0.87), and EFC (0.60) (p < 0.001 for all). Diagnostic accuracy of SVM was comparable to the overall accuracy of both visual readers (85% vs. 84%, p < 0.05). ROC-AUC for SVM (0.92) was significantly better than that of both visual readers (0.87 and 0.88, p < 0.03). Conclusion Computational

  20. Association between gender, process of care measures, and outcomes in ACS in India: results from the detection and management of coronary heart disease (DEMAT registry.

    Directory of Open Access Journals (Sweden)

    Neha J Pagidipati

    Full Text Available Studies from high-income countries have shown that women receive less aggressive diagnostics and treatment than men in acute coronary syndromes (ACS, though their short-term mortality does not appear to differ from men. Data on gender differences in ACS presentation, management, and outcomes are sparse in India.The Detection and Management of Coronary Heart Disease (DEMAT Registry collected data from 1,565 suspected ACS patients (334 women; 1,231 men from ten tertiary care centers throughout India between 2007-2008. We evaluated gender differences in presentation, in-hospital and discharge management, and 30-day death and major adverse cardiovascular event (MACE; death, re-hospitalization, and cardiac arrest rates. Women were less likely to present with STEMI than men (38% vs. 55%, p<0.001. Overall inpatient diagnostics and treatment patterns were similar between men and women after adjustment for potential confounders. Optimal discharge management with aspirin, clopidogrel, beta-blockers, and statin therapy was lower for women than men, (58% vs. 65%, p = 0.03, but these differences were attenuated after adjustment (OR = 0.86 (0.62, 1.19. Neither the outcome of 30-day mortality (OR = 1.40 (0.62, 3.16 nor MACE (OR = 1.00 (0.67, 1.48 differed significantly between men and women after adjustment.ACS in-hospital management, discharge management, and 30-day outcomes did not significantly differ between genders in the DEMAT registry, though consistently higher treatment rates and lower event rates in men compared to women were seen. These findings underscore the importance of further investigation of gender differences in cardiovascular care in India.

  1. Myocardial perfusion magnetic resonance imaging using sliding-window conjugate-gradient highly constrained back-projection reconstruction for detection of coronary artery disease.

    Science.gov (United States)

    Ma, Heng; Yang, Jun; Liu, Jing; Ge, Lan; An, Jing; Tang, Qing; Li, Han; Zhang, Yu; Chen, David; Wang, Yong; Liu, Jiabin; Liang, Zhigang; Lin, Kai; Jin, Lixin; Bi, Xiaoming; Li, Kuncheng; Li, Debiao

    2012-04-15

    Myocardial perfusion magnetic resonance imaging (MRI) with sliding-window conjugate-gradient highly constrained back-projection reconstruction (SW-CG-HYPR) allows whole left ventricular coverage, improved temporal and spatial resolution and signal/noise ratio, and reduced cardiac motion-related image artifacts. The accuracy of this technique for detecting coronary artery disease (CAD) has not been determined in a large number of patients. We prospectively evaluated the diagnostic performance of myocardial perfusion MRI with SW-CG-HYPR in patients with suspected CAD. A total of 50 consecutive patients who were scheduled for coronary angiography with suspected CAD underwent myocardial perfusion MRI with SW-CG-HYPR at 3.0 T. The perfusion defects were interpreted qualitatively by 2 blinded observers and were correlated with x-ray angiographic stenoses ≥50%. The prevalence of CAD was 56%. In the per-patient analysis, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of SW-CG-HYPR was 96% (95% confidence interval 82% to 100%), 82% (95% confidence interval 60% to 95%), 87% (95% confidence interval 70% to 96%), 95% (95% confidence interval 74% to100%), and 90% (95% confidence interval 82% to 98%), respectively. In the per-vessel analysis, the corresponding values were 98% (95% confidence interval 91% to 100%), 89% (95% confidence interval 80% to 94%), 86% (95% confidence interval 76% to 93%), 99% (95% confidence interval 93% to 100%), and 93% (95% confidence interval 89% to 97%), respectively. In conclusion, myocardial perfusion MRI using SW-CG-HYPR allows whole left ventricular coverage and high resolution and has high diagnostic accuracy in patients with suspected CAD. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Comparison of the TIMI and the GRACE risk scores with the extent of coronary artery disease in patients with non-ST-elevation acute coronary syndrome

    International Nuclear Information System (INIS)

    Mahmood, M.; Achakzai, A.S.; Akhtar, P.; Zaman, K.S.

    2013-01-01

    Objective: To compare the accuracy of the Global Registry of Acute Coronary Events risk score and the Thrombolysis In Myocardial Infarction risk score in predicting the extent of coronary artery disease in patients with non-ST segment elevation acute coronary syndrome. Methods: The cross-sectional study comprising 406 consecutive patients was conducted at the National Institute of Cardiovascular Diseases, Karachi, from August 2010 to March 2011. For all patients, the GRACE and TIMI RS's relevant scores on the two indices were calculated on admission using specified variables. The patients underwent coronary angiography to determine the extent of the disease. A significant level was defined as >70% stenosis in any major epicardial artery or >50% stenosis in the left main coronary artery. SPSS 19 was used for statistical analysis. Results: Both the indices showed good predictive value in identifying the extent of the disease. A Thrombolysis In Myocardial Infarction score >4 and Global Registry of Acute Coronary Events score >133 was significantly associated with 3vessel disease and left main disease, while for the former score <4 and latter score <133 was associated with normal or non-obstructive coronary disease (p<0.01). On comparison of the two risk scores, the discriminatory accuracy of the latter was significantly superior to the former in predicting 2vessel, 3vessel and left main diseases (p<0.05). Conclusion: Although both the indices were helpful in predicting the extent of the disease, the Global Registry showed better performance and was more strongly associated with multi-vessel and left main coronary artery disease. (author)

  3. Multislice CT imaging of anomalous coronary arteries

    International Nuclear Information System (INIS)

    Shi Heshui; Aschoff, Andrik J.; Brambs, Hans-Juergen; Hoffmann, Martin H.K.

    2004-01-01

    The purpose of the present study was to evaluate the role of 16 multislice computed tomography (MSCT) to identify the origin of anomalous coronary arteries and to confirm their anatomic course in relation to the great vessels. Accuracy of coronary artery disease (CAD) detection was a secondary aim and was tested with conventional angiograms (CA) serving as standard of reference. Two hundred and forty-two consecutive patients referred for noninvasive coronary CT imaging were reviewed for the study. Sixteen patients (6.6%) with anomalous coronary arteries were detected and included as the study group. MSCT and CA images were analyzed in a blinded fashion for accuracy of anomalous artery origin and path detection. Results were compared in a secondary consensus evaluation. Accuracy ratios to detect CAD with MSCT in all vessels were calculated. Coronary anomalies for all 16 patients were correctly displayed on MSCT. CA alone achieved correct identification of the abnormality in only 53% (P=0.016). Sensitivity and specificity of MSCT to detect significantly stenosed vessels was 90 and 92%. 16-MSCT is accurate to delineate abnormally branching coronary arteries and allows sufficiently accurate detection of obstructive coronary artery disease in distal branches. It should therefore be considered as a prime non-invasive imaging tool for suspected coronary anomalies. (orig.)

  4. Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease

    Science.gov (United States)

    Schlegel, Todd T.; Kulecz, Walter B.; DePalma, Jude L.; Feiveson, Alan H.; Wilson, John S.; Rahman, M. Atiar; Bungo, Michael W.

    2004-01-01

    Several studies have shown that diminution of the high-frequency (HF; 150-250 Hz) components present within the central portion of the QRS complex of an electrocardiogram (ECG) is a more sensitive indicator for the presence of myocardial ischemia than are changes in the ST segments of the conventional low-frequency ECG. However, until now, no device has been capable of displaying, in real time on a beat-to-beat basis, changes in these HF QRS ECG components in a continuously monitored patient. Although several software programs have been designed to acquire the HF components over the entire QRS interval, such programs have involved laborious off-line calculations and postprocessing, limiting their clinical utility. We describe a personal computer-based ECG software program developed recently at the National Aeronautics and Space Administration (NASA) that acquires, analyzes, and displays HF QRS components in each of the 12 conventional ECG leads in real time. The system also updates these signals and their related derived parameters in real time on a beat-to-beat basis for any chosen monitoring period and simultaneously displays the diagnostic information from the conventional (low-frequency) 12-lead ECG. The real-time NASA HF QRS ECG software is being evaluated currently in multiple clinical settings in North America. We describe its potential usefulness in the diagnosis of myocardial ischemia and coronary artery disease.

  5. Performance of highly sensitive cardiac troponin T assay to detect ischaemia at PET-CT in low-risk patients with acute coronary syndrome: a prospective observational study.

    Science.gov (United States)

    Morawiec, Beata; Fournier, Stephane; Tapponnier, Maxime; Prior, John O; Monney, Pierre; Dunet, Vincent; Lauriers, Nathalie; Recordon, Frederique; Trana, Catalina; Iglesias, Juan-Fernando; Kawecki, Damian; Boulat, Olivier; Bardy, Daniel; Lamsidri, Sabine; Eeckhout, Eric; Hugli, Olivier; Muller, Olivier

    2017-07-10

    Highly sensitive troponin T (hs-TnT) assay has improved clinical decision-making for patients admitted with chest pain. However, this assay's performance in detecting myocardial ischaemia in a lowrisk population has been poorly documented. To assess hs-TnT assay's performance to detect myocardial ischaemia at positron emission tomography/CT (PET-CT) in low-risk patients admitted with chest pain. Patients admitted for chest pain with a nonconclusive ECG and negative standard cardiac troponin T results at admission and after 6 hours were prospectively enrolled. Their hs-TnT samples were at T0, T2 and T6. Physicians were blinded to hs-TnT results. All patients underwent a PET-CT at rest and during adenosine-induced stress. All patients with a positive PET-CT result underwent a coronary angiography. Forty-eight patients were included. Six had ischaemia at PET-CT. All of them had ≥1 significant stenosis at coronary angiography. Areas under the curve (95% CI) for predicting significant ischaemia at PET-CT using hs-TnT were 0.764 (0.515 to 1.000) at T0, 0.812(0.616 to 1.000) at T2 and 0.813(0.638 to 0.989) at T6. The receiver operating characteristicbased optimal cut-off value for hs-TnT at T0, T2 and T6 needed to exclude significant ischaemia at PET-CT was <4 ng/L. Using this value, sensitivity, specificity, positive and negative predictive values of hs-TnT to predict significant ischaemia were 83%/38%/16%/94% at T0, 100%/40%/19%/100% at T2 and 100%/43%/20%/100% at T6, respectively. Our findings suggest that in low-risk patients, using the hs-TnT assay with a cut-off value of 4 ng/L demonstrates excellent negative predictive value to exclude myocardial ischaemia detection at PET-CT, at the expense of weak specificity and positive predictive value. ClinicalTrials.gov Identifier: NCT01374607. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly

  6. Contemporary sex differences among patients with acute coronary syndrome treated by emergency percutaneous coronary intervention.

    Science.gov (United States)

    Wada, Hideki; Ogita, Manabu; Miyauchi, Katsumi; Tsuboi, Shuta; Konishi, Hirokazu; Shitara, Jun; Kunimoto, Mitsuhiro; Sonoda, Taketo; Iso, Takashi; Ebina, Hideki; Aoki, Eriko; Kitamura, Kenichi; Tamura, Hiroshi; Suwa, Satoru; Daida, Hiroyuki

    2017-10-01

    Acute coronary syndrome (ACS) is an important cause of mortality and morbidity in the general population. Recent advances in percutaneous coronary intervention (PCI) and optimal medical treatment have helped to improve the prognosis of patients with ACS. The previous reports indicated that women with ACS have a higher risk of adverse outcomes. However, sex differences in clinical outcomes with contemporary coronary revascularization and medical therapy for ACS have not been elucidated. We analyzed data from 676 consecutive patients with ACS (female, n = 166; male, n = 510) who were treated by emergency PCI between 2011 and 2014 at Juntendo Shizuoka Hospital. The patients were grouped according to sex. We defined major adverse cardiovascular events as a composite of all-cause death and ACS recurrence at 1 year and compared rates of major adverse cardiac events (MACE) between the groups. Women were older (75.4 ± 11.0 vs. 66.2 ± 12.2 years) and had a higher rate of multi-vessel disease, chronic kidney disease, and Killip IV at presentation. The cumulative rate of MACE at 1 year was significantly higher among women than men (17.5 vs. 10.2 %, p = 0.02, log-rank test). However, the association between women and a higher risk of MACE was attenuated after adjusting for age (HR 1.25, 95 % CI 0.77-2.00, p = 0.36) and other variables (HR 0.93, 95 % CI 0.36-2.44, p = 0.88). Adjustment for age and other risk factors attenuated sex differences in mid-term clinical outcomes among patients with ACS after emergency PCI.

  7. Utility of the History and Physical Examination in the Detection of Acute Coronary Syndromes in Emergency Department Patients

    Directory of Open Access Journals (Sweden)

    Zachary DW Dezman

    2017-05-01

    Full Text Available Chest pain accounts for approximately 6% of all emergency department (ED visits and is the most common reason for emergency hospital admission. One of the most serious diagnoses emergency physicians must consider is acute coronary syndrome (ACS. This is both common and serious, as ischemic heart disease remains the single biggest cause of death in the western world. The history and physical examination are cornerstones of our diagnostic approach in this patient group. Their importance is emphasized in guidelines, but there is little evidence to support their supposed association. The purpose of this article was to summarize the findings of recent investigations regarding the ability of various components of the history and physical examination to identify which patients presenting to the ED with chest pain require further investigation for possible ACS. Previous studies have consistently identified a number of factors that increase the probability of ACS. These include radiation of the pain, aggravation of the pain by exertion, vomiting, and diaphoresis. Traditional cardiac risk factors identified by the Framingham Heart Study are of limited diagnostic utility in the ED. Clinician gestalt has very low predictive ability, even in patients with a non-diagnostic electrocardiogram (ECG, and gestalt does not seem to be enhanced appreciably by clinical experience. The history and physical alone are unable to reduce a patient’s risk of ACS to a generally acceptable level (<1%. Ultimately, our review of the evidence clearly demonstrates that “atypical” symptoms cannot rule out ACS, while “typical” symptoms cannot rule it in. Therefore, if a patient has symptoms that are compatible with ACS and an alternative cause cannot be identified, clinicians must strongly consider the need for further investigation with ECG and troponin measurement.

  8. Improvement of myocardial perfusion detected by 201Tl scintigraphy on cardiac rehabilitation for patients with coronary artery disease

    International Nuclear Information System (INIS)

    Li, Linxue; Nohara, Ryuji; Makita, Shigeru

    1996-01-01

    The effect of cardiac rehabilitation (mean 70±48 months) on myocardial perfusion was assessed using thallium-201 ( 201 Tl) exercise study in 63 patients with coronary artery disease (CAD). Subjects were those in a rehabilitation group (Rh=42) participating in supervised sports training two to three times per week and the control group (Ct=21) not taking active daily exercise. The interval between two 201 Tl SPECT studies was 19±16 months. After physical training, total duration of the exercise test increased from 443±112 to 536±121 seconds (+19%) in the Rh group, and from 484±129 to 432±115 seconds in the Ct group (-10.7%) (p 2 to 269.8±58 x 10 2 in the Rh group and decreased from 218.7±40 x 10 2 to 216.6±76 x 10 2 (p 201 Tl myocardial perfusion defect on exercise improved more in 54.8% (stress 59.5%, rest 35.7%) in the Rh group than in the Ct group (9.5%, p 201 Tl perfusion defect decreased from 68 (23.1%) to 49 regions (16.7%) of 294 total myocardial regions in the Rh group on exercise. However. it increased from 39 (26.5%) to 44 (29.9%) regions of 147 regions in the Ct group (p<0.01). Thus, cardiac rehabilitation increases exercise tolerance with improvement of myocardial perfusion. suggesting that cardiac rehabilitation is an advisable and effective treatment for patients with ischemic heart disease. (author)

  9. Depression following acute coronary syndrome

    DEFF Research Database (Denmark)

    Joergensen, Terese Sara Hoej; Maartensson, Solvej; Ibfelt, Else Helene

    2016-01-01

    PURPOSE: Depression is common following acute coronary syndrome, and thus, it is important to provide knowledge to improve prevention and detection of depression in this patient group. The objectives of this study were to examine: (1) whether indicators of stressors and coping resources were risk...... factors for developing depression early and later after an acute coronary syndrome and (2) whether prior depression modified these associations. METHODS: The study was a register-based cohort study, which includes 87,118 patients with a first time diagnosis of acute coronary syndrome during the period...... 2001-2009 in Denmark. Cox regression models were used to analyse hazard ratios (HRs) for depression. RESULTS: 1.5 and 9.5 % develop early (≤30 days) and later (31 days-2 years) depression after the acute coronary syndrome. Among all patients with depression, 69.2 % had first onset depression, while 30...

  10. Quantitation of myocardial blood flow and myocardial flow reserve with {sup 99m}Tc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Bailing [University of Missouri-Columbia, Nuclear Science and Engineering Institute, Columbia, MO (United States); Chen, Fu-Chung; Chen, Chien-Cheng [Show Chwan Memorial Hospital, Section of Cardiology, Department of Internal Medicine, Changhua (China); Wu, Tao-Cheng [Taipei Veterans General Hospital, Section of Cardiology, Department of Internal Medicine, Taipei (China); Huang, Wen-Sheng [Changhua Christian Hospital, Department of Medical Research and Department of Nuclear Medicine, Changhua (China); Hou, Po-Nien [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Lukong Town, Changhua Shien (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Lukong Town, Changhua Shien (China); Central Taiwan University of Science and Technology, Department of Medical Imaging and Radiological Science, Taichung (China); China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China)

    2014-12-15

    Conventional dual-head single photon emission computed tomography (SPECT)/CT systems capable of fast dynamic SPECT (DySPECT) imaging have a potential for flow quantitation. This study introduced a new method to quantify myocardial blood flow (MBF) and myocardial flow reserve (MFR) with DySPECT scan and evaluated the diagnostic performance of detecting coronary artery disease (CAD) compared with perfusion using invasive coronary angiography (CAG) as the reference standard. This study included 21 patients with suspected or known CAD who had received DySPECT, ECG-gated SPECT (GSPECT), and CAG (13 with ≥50 % stenosis in any vessel; non-CAD group: 8 with patent arteries or <50 % stenosis). DySPECT and GSPECT scans were performed on a widely used dual-head SPECT/CT scanner. The DySPECT imaging protocol utilized 12-min multiple back-and-forth gantry rotations during injections of {sup 99m}Tc-sestamibi (MIBI) tracer at rest or dipyridamole-stress stages. DySPECT images were reconstructed with full physical corrections and converted to the physical unit of becquerels per milliliter. Stress MBF (SMBF), rest MBF (RMBF), and MFR were quantified by a one-tissue compartment flow model using time-activity curves derived from DySPECT images. Perfusion images were processed for GSPECT scan and interpreted to obtain summed stress score (SSS) and summed difference score (SDS). Receiver-operating characteristic (ROC) analyses were conducted to evaluate the diagnostic performance of flow and perfusion. Using the criteria of ≥50 % stenosis as positive CAD, areas under the ROC curve (AUCs) of flow assessment were overall significantly greater than those of perfusion. For patient-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.91 ± 0.07, 0.86 ± 0.09, 0.64 ± 0.12, and 0.59 ± 0.13. For vessel-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.81 ± 0.05, 0.76 ± 0.06, 0.62 ± 0.07, and 0.56 ± 0.08, respectively. The preliminary data suggest that MBF quantitation with a

  11. Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease

    International Nuclear Information System (INIS)

    Hsu, Bailing; Chen, Fu-Chung; Chen, Chien-Cheng; Wu, Tao-Cheng; Huang, Wen-Sheng; Hou, Po-Nien; Hung, Guang-Uei

    2014-01-01

    Conventional dual-head single photon emission computed tomography (SPECT)/CT systems capable of fast dynamic SPECT (DySPECT) imaging have a potential for flow quantitation. This study introduced a new method to quantify myocardial blood flow (MBF) and myocardial flow reserve (MFR) with DySPECT scan and evaluated the diagnostic performance of detecting coronary artery disease (CAD) compared with perfusion using invasive coronary angiography (CAG) as the reference standard. This study included 21 patients with suspected or known CAD who had received DySPECT, ECG-gated SPECT (GSPECT), and CAG (13 with ≥50 % stenosis in any vessel; non-CAD group: 8 with patent arteries or 99m Tc-sestamibi (MIBI) tracer at rest or dipyridamole-stress stages. DySPECT images were reconstructed with full physical corrections and converted to the physical unit of becquerels per milliliter. Stress MBF (SMBF), rest MBF (RMBF), and MFR were quantified by a one-tissue compartment flow model using time-activity curves derived from DySPECT images. Perfusion images were processed for GSPECT scan and interpreted to obtain summed stress score (SSS) and summed difference score (SDS). Receiver-operating characteristic (ROC) analyses were conducted to evaluate the diagnostic performance of flow and perfusion. Using the criteria of ≥50 % stenosis as positive CAD, areas under the ROC curve (AUCs) of flow assessment were overall significantly greater than those of perfusion. For patient-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.91 ± 0.07, 0.86 ± 0.09, 0.64 ± 0.12, and 0.59 ± 0.13. For vessel-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.81 ± 0.05, 0.76 ± 0.06, 0.62 ± 0.07, and 0.56 ± 0.08, respectively. The preliminary data suggest that MBF quantitation with a conventional SPECT/CT system and the flow quantitation method is a clinically effective approach to enhance CAD detection. (orig.)

  12. Coronary anomalies: what the radiologist should know*

    Science.gov (United States)

    Neves, Priscilla Ornellas; Andrade, Joalbo; Monção, Henry

    2015-01-01

    Coronary anomalies comprise a diverse group of malformations, some of them asymptomatic with a benign course, and the others related to symptoms as chest pain and sudden death. Such anomalies may be classified as follows: 1) anomalies of origination and course; 2) anomalies of intrinsic coronary arterial anatomy; 3) anomalies of coronary termination. The origin and the proximal course of anomalous coronary arteries are the main prognostic factors, and interarterial course or a coronary artery is considered to be malignant due its association with increased risk of sudden death. Coronary computed tomography angiography has become the reference method for such an assessment as it detects not only anomalies in origination of these arteries, but also its course in relation to other mediastinal structures, which plays a relevant role in the definition of the therapeutic management. Finally, it is essential for radiologists to recognize and characterize such anomalies. PMID:26379322

  13. Mortality after percutaneous coronary revascularization: Prior cardiovascular risk factor control and improved outcomes in patients with diabetes mellitus.

    Science.gov (United States)

    Noman, Awsan; Balasubramaniam, Karthik; Alhous, M Hafez A; Lee, Kelvin; Jesudason, Peter; Rashid, Muhammad; Mamas, Mamas A; Zaman, Azfar G

    2017-06-01

    To assess the mortality in patients with diabetes mellitus (DM) following percutaneous coronary intervention (PCI) according to their insulin requirement and PCI setting (elective, urgent, and emergency). DM is a major risk factor to develop coronary artery disease (CAD). It is unclear if meticulous glycemic control and aggressive risk factor management in patients with DM has improved outcomes following PCI. Retrospective analysis of prospectively collected data on 9,224 patients treated with PCI at a regional tertiary center between 2008 and 2011. About 7,652 patients were nondiabetics (non-DM), 1,116 had non-insulin treated diabetes mellitus (NITDM) and 456 had ITDM. Multi-vessel coronary artery disease, renal impairment and non-coronary vascular disease were more prevalent in DM patients. Overall 30-day mortality rate was 2.4%. In a logistic regression model, the adjusted odds ratios (95% confidence intervals [CI]) for 30-day mortality were 1.28 (0.81-2.03, P = 0.34) in NITDM and 2.82 (1.61-4.94, P diabetes, this study reveals higher mortality only in insulin-treated diabetic patients following PCI for stable coronary artery disease and acute coronary syndrome. Importantly, diabetic patients with good risk factor control and managed on diet or oral hypoglycemics have similar outcomes to the non-diabetic population. © 2016 The Authors Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc. © 2016 The Authors Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.

  14. Assessment of various systolic phase indexes for the detection of coronary artery disease by multi-gated blood pool imaging at rest

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru; Kanao, Keisuke

    1982-01-01

    After Tc-99m was labeled with red blood cells in vivo, multi-gated blood pool imaging (MGBPI) was obtained at anterior and 40-degree left anterior oblique (LAO) position at rest. In addition to left ventricular (LV) ejection fraction (EF) and wall motion (WM) abnormality, first-third EF, mean normalized systolic ejection rate, SdV/dt/EDV (LV peak ejection rate normalized by end-diastolic volume) and SdV/dt/V (peak ejection rate normalized by LV volume at the peak ejection) were calculated. Patients were divided into 3 groups; Normal (n = 14), coronary artery disease (CAD) with normal EF (> = 55%) and normal WM (Group I, n = 16), and CAD with abnormal EF and/or WM abnormality (Group II, n = 31). In all subjects of Normal and 13 patients of Group I, graded supine exercise stress MGBPI was performed at LAO position by using bicycle ergometer. All systolic phase indexes were correlated well with EF (r > = 0.77, p - 1 , p - 1 as a criteria of CAD, sensitivity of this index was 91% (100% in Group II and 75% in Group I). This sensitivity in Group I was identical with that of exercise stress MGBPI. Specificity of SdV/dt/V (86%) was a little inferior to that of exercise stress MGBPI (93%), but it was not statistically significant. In conclusion, SdV/dt/V is a useful systolic phase index to detect CAD. (J.P.N.)

  15. Comparison of dobutamine-stress magnetic resonance imaging and dipyridamole-Tl-201-SPECT as alternative strategies for the detection of coronary artery disease in patients not suitable for stress-echocardiography

    International Nuclear Information System (INIS)

    Schmidt, M.; Theissen, P.; Voth, E.; Schicha, H.; Jochims, M.; Baer, F.M.; Crnac, J.; Schneider, C.A.; Erdmann, E.

    2001-01-01

    Aim: During the past decade stress-echocardiography has gained increasing popularity for detection of myocardial ischemia in patients with coronary artery disease. However, about 10% to 15% of the patients submitted for stress-echocardiography do not have an adequate acoustic window. The purpose of this study was to compare high-dose dobutamine-stress magnetic resonance imaging (dobutamine-MRI) with dipyridamole-Tl-201-SPECT (dipyridamole-SPECT) as alternative strategies for detection of myocardial ischemia in patients with inadequate image quality by stress-echocardiography. Patients and Methods: Of 296 patients which were consecutively submitted to stress-echo-cardiography 45 patients (15%) had two or more segments that could not be evaluated according to the 16-segment-model of the American Society of Echocardiography. They underwent dobutamine-MRI and dipyridamole-SPECT studies, which were evaluated using a 28-segment modell. Myocardial segments were attributed to perfusion territories of the coronary arteries. The results of ischemia detection were compared to the results of coronary angiography (stenosis ≥50%). Results: In comparison to coronary angiography dobutamine-MRI yielded a sensitivity of 87%, a specificity of 86%, a positive predictive value of 93%, a negative predictive value of 75% and a diagnostic accuracy of 86%. For dipyridamole-SPECT results were 90%, 86%, 93%, 80% and 89%, respectively. These values were not significantly different. Conclusions: In patients not suitable for stress-echocardiography, both dobutamine-MRI and dipyridamole-SPECT are reliable strategies for detection of myocardial ischemia. Selection is dependent on the patient criteria, technical considerations, local logistics and experience of the observer. (orig.) [de

  16. The ability of NT-proBNP to detect chronic heart failure and predict all-cause mortality is higher in elderly Chinese coronary artery disease patients with chronic kidney disease

    OpenAIRE

    Fu, Shihui; Yi,Shuangyan; Liu,Yuan; Zhu,Bing; Wang,Liang; Tiehui Xiao,; Bai,Yongyi; Ye,Ping; Luo,Leiming

    2013-01-01

    Shihui Fu, Leiming Luo, Ping Ye, Shuangyan Yi, Yuan Liu, Bing Zhu, Liang Wang, Tiehui Xiao, Yongyi Bai Department of Geriatric Cardiology, Chinese PLA General Hospital, Beijing, People's Republic of China Objective: To analyze the relationship between N-terminal pro-brain natriuretic peptide (NT-proBNP) and renal function, and compare the ability and cut-off thresholds of NT-proBNP to detect chronic heart failure (CHF) and predict mortality in elderly Chinese coronary artery disease ...

  17. Association between diabetes and different components of coronary atherosclerotic plaque burden as measured by coronary multidetector computed tomography.

    Science.gov (United States)

    Yun, Chun-Ho; Schlett, Christopher L; Rogers, Ian S; Truong, Quynh A; Toepker, Michael; Donnelly, Patrick; Brady, Thomas J; Hoffmann, Udo; Bamberg, Fabian

    2009-08-01

    The aim of the study was to assess differences in the presence, extent, and composition of coronary atherosclerotic plaque burden as detected by coronary multidetector computed tomography (MDCT) between patients with and without diabetes mellitus. We compared coronary atherosclerotic plaques (any plaque, calcified [CAP], non-calcified [NCAP, and mixed plaque [MCAP

  18. Dobutamine stress tetrofosmin SPECT. Evaluation of short rest-stress protocol and head to head comparison with MIBI in detection of coronary artery disease

    International Nuclear Information System (INIS)

    Turgut, B.; Unlu, M.; Cengel, A.

    2005-01-01

    The purpose of the present study was to evaluate the feasibility and diagnostic accuracy of same day short rest-dobutamine stress Tetrofosmin (TF) SPECT imaging protocol and to compare TF SPECT results with methoxyisobutyl isonitrile (MIBI) SPECT in the same subjects who were unable to perform treadmill exercise or were unsuitable for pharmacological vasodilator stress. The study group consisted of 19 patients (2 female and 17 male, with a mean age of 53.8±7.9 yrs) in whom coronary artery disease (CAD) had been proven or excluded at coronary angiography (CA). MIBI SPECT imaging was performed first. TF SPECT images were obtained one week after MIBI imaging. Immediately after the rest SPECT imaging in both of the MIBI and TF studies, patients underwent dobutamine stress tests. Rest-stress radiotracer doses and dobutamine doses were the same for both TF and MIBI studies. While 60 min waiting periods were applied for MIBI study, only 30 min waiting periods were applied for TF study after the rest and stress injections. Images were evaluated by visual and quantitative analysis. Dobutamine stress parameters were similar for both studies. Although in TF study, the time between radiopharmaceutical injection and imaging was shorter than in MIBI study, there was no significant difference between heart-to-liver (H/Li) and heart-to-lung (H/Lu) ratios. According to CA results, diagnostic accuracy was similar for TF and MIBI. While sensitivity, specificity and accuracy for TF study were calculated as 82%, 84% and 82%, respectively, the corresponding values for MIBI were 82%, 88% and 84%, respectively. This clinical study has shown comparable diagnostic performance for the detection of CAD between MIBI and TF. Good correlation was found between segmental analysis for both studies. MIBI and TF showed similar perfusion defects and good segmental correlation during dobutamine stress with the same quality images. Both radiopharmaceuticals may be acceptable with this imaging protocol

  19. Detection of Obstructive Coronary Artery Disease Using Peak Systolic Global Longitudinal Strain Derived by Two-Dimensional Speckle-Tracking: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Liou, Kevin; Negishi, Kazuaki; Ho, Suyen; Russell, Elizabeth A; Cranney, Greg; Ooi, Sze-Yuan

    2016-08-01

    Global longitudinal strain (GLS) is well validated and has important applications in contemporary clinical practice. The aim of this analysis was to evaluate the accuracy of resting peak GLS in the diagnosis of obstructive coronary artery disease (CAD). A systematic literature search was performed through July 2015 using four databases. Data were extracted independently by two authors and correlated before analyses. Using a random-effect model, the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and summary area under the curve for GLS were estimated with their respective 95% CIs. Screening of 1,669 articles yielded 10 studies with 1,385 patients appropriate for inclusion in the analysis. The mean age and left ventricular ejection fraction were 59.9 years and 61.1%. On the whole, 54.9% and 20.9% of the patients had hypertension and diabetes, respectively. Overall, abnormal GLS detected moderate to severe CAD with a pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of 74.4%, 72.1%, 2.9, and 0.35 respectively. The area under the curve and diagnostic odds ratio were 0.81 and 8.5. The mean values of GLS for those with and without CAD were -16.5% (95% CI, -15.8% to -17.3%) and -19.7% (95% CI, -18.8% to -20.7%), respectively. Subgroup analyses for patients with severe CAD and normal left ventricular ejection fractions yielded similar results. Current evidence supports the use of GLS in the detection of moderate to severe obstructive CAD in symptomatic patients. GLS may complement existing diagnostic algorithms and act as an early adjunctive marker of cardiac ischemia. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  20. Effect of eicosapentaenoic acid/docosahexaenoic acid on coronary high-intensity plaques detected with non-contrast T1-weighted imaging (the AQUAMARINE EPA/DHA study): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Nakao, Kazuhiro; Noguchi, Teruo; Asaumi, Yasuhide; Morita, Yoshiaki; Kanaya, Tomoaki; Fujino, Masashi; Hosoda, Hayato; Yoneda, Shuichi; Kawakami, Shoji; Nagai, Toshiyuki; Nishihira, Kensaku; Nakashima, Takahiro; Kumasaka, Reon; Arakawa, Tetsuo; Otsuka, Fumiyuki; Nakanishi, Michio; Kataoka, Yu; Tahara, Yoshio; Goto, Yoichi; Yamamoto, Haruko; Hamasaki, Toshimitsu; Yasuda, Satoshi

    2018-01-08

    Despite the success of HMG-CoA reductase inhibitor (statin) therapy in reducing atherosclerotic cardiovascular events, a residual risk for cardiovascular events in patients with coronary artery disease (CAD) remains. Long-chain n-3 polyunsaturated fatty acids (LC n-3 PUFAs), especially eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA), are promising anti-atherosclerosis agents that might reduce the residual CAD risk. Non-contrast T1-weighted imaging (T1WI) with cardiac magnetic resonance (CMR) less invasively identifies high-risk coronary plaques as high-intensity signals. These high-intensity plaques (HIPs) are quantitatively assessed using the plaque-to-myocardium signal intensity ratio (PMR). Our goal is to assess the effect of EPA/DHA on coronary HIPs detected with T1WI in patients with CAD on statin treatment. This prospective, controlled, randomized, open-label study examines the effect of 12 months of EPA/DHA therapy and statin treatment on PMR of HIPs detected with CMR and computed tomography angiography (CTA) in patients with CAD. The primary endpoint is the change in PMR after EPA/DHA treatment. Secondary endpoints include changes in Hounsfield units, plaque volume, vessel area, and plaque area measured using CTA. Subjects are randomly assigned to either of three groups: the 2 g/day EPA/DHA group, the 4 g/day EPA/DHA group, or the no-treatment group. This trial will help assess whether EPA/DHA has an anti-atherosclerotic effect using PMR of HIPs detected by CMR. The trial outcomes will provide novel insights into the effect of EPA/DHA on high-risk coronary plaques and may provide new strategies for lowering the residual risk in patients with CAD on statin therapy. The University Hospital Medical Information Network (UMIN) Clinical Trials Registry, ID: UMIN000015316 . Registered on 2 October 2014.

  1. Anterior ischemic optic neuropathy after conventional coronary artery bypass graft surgery.

    Science.gov (United States)

    Dorecka, Mariola; Miniewicz-Kurkowska, Joanna; Romaniuk, Dorota; Gajdzik-Gajdecka, Urszula; Wójcik-Niklewska, Bogumiła

    2011-06-01

    Perioperative optic neuropathy is a disease which can lead to serious, irreversible damage of vision. This complication could be the result of non-ocular surgery, for example, cardiac or spinal procedures. We present a case of anterior ischemic neuropathy (AION) which occurred following a conventional coronary artery bypass graft procedure. A 57-year-old man, 4 days after Conventional Coronary Artery Bypass Graft surgery as result of multi-vessel stabile coronary artery disease and history of anterolateral wall myocardial infarction, was admitted to the Eye Clinic due to significant loss of vision in his right eye. The patient had hypertension and was a heavy smoker. On admission, the slit lamp examination revealed a relative afferent pupillary defect in the right eye. The fundus examination showed optic disc edema with the presence of flame hemorrhages. Best corrected visual acuity (BCVA) was 0.02. The results of eye examination and fluorescein angiography confirmed the diagnosis of AION. Anti-aggregation and antithrombotic treatment was continued with steroids and vasodilators. After 7 days of this treatment we noticed the improvement of BCVA to 0.2. At 6-month follow-up, the vision was stable, and fundus examination revealed optic disc atrophy. After cardiac surgical operations, such as coronary artery bypass graft procedures, anterior ischemic optic neuropathy may occur. In those cases, close cooperation between the various specialists is necessary.

  2. Description of a Heart Team approach to coronary revascularization and its beneficial long-term effect on clinical events after PCI.

    Science.gov (United States)

    Bonzel, Tassilo; Schächinger, Volker; Dörge, Hilmar

    2016-05-01

    We present a first description of a Heart Team (HT)-guided approach to coronary revascularization and its long-term effect on clinical events after percutaneous coronary intervention (PCI). The HT approach is a structured process to decide for coronary bypass grafting (CABG), PCI or conservative therapy in ad hoc situations as well as in HT conferences. As a hypothesis, during the long-term course after a PCI performed according to HT rules, a low number of late revascularizations, especially CABGs, are expected (F-PCI study). In this monocentric study, the HT approach to an all-comer population was first analyzed and described in general with the help of a database. Next the use of a HT approach was described for a more homogeneous subgroup with newly detected CAD (1.CAD). Those patients in whom the HT decision was PCI (which was a 1.PCI) were then studied with the help of questionnaires for clinical events during a very long-term follow-up. Events were CABG, PCI, diagnostic catheterization (DCath) and death. A significant number of patients were presented to HT conferences: 22 % out of all 11,174 catheterizations, 24 % out of all 7867 CAD cases and 35 % out of 3408 1.CAD cases. Most of these patients had multi-vessel disease (MVD). Conference decisions were isolated CABG in 46-66 %, PCI in 10-14 %, valvular surgery in 9-16 %, HTx in 10-21 % (Endstage heart failure candidates for surgery) and conservative therapy (Medical or no therapy, additional diagnostic procedures or no adherence to recommended therapy) in 2-3 %. However, most PCIs, ad hoc and elective, were performed under Heart Team rules, but without conference. During follow-up of 1.PCI patients (Kaplan-Meier analysis), CABG occurred in only 15 % of patients, PCI in 37 % and DCath in 65 %; mortality of any course was 51 %. Mortalities were similar in one-vessel disease and in a population of the same year, matched for age and sex (p PCI patients with MVD (p PCI) rates after a 1.PCI, without

  3. Comparison of Myocardial Perfusion Scintigraphy and Coronary Angiography Results

    Directory of Open Access Journals (Sweden)

    Umut Elboga

    2017-05-01

    Full Text Available Aim: Coronary artery disease (CAD is one of the most frequent causes of mortality and morbidity worldwide. Coronary angiography is the gold standard for the anatomical diagnosis of coronary artery stenosis. Myocardial Perfusion Scintigraphy (MPS is a non-invasive imaging modality used for the diagnosis of CAD. In this study, we aimed to compare the findings of MPS and coronary angiogram. Material and Method: Eighty-one patients (37 males, 44 females; mean age 55 ± 10.95 years with angina and detected perfusion defects on MPS were included in this study. All of the patients underwent coronary angiogram. A narrowing %u2265 50% was considered pathological on the coronary angiography. Results: Findings of the coronary angiogram and MPS were compared and found consistent in 51 (63% patients. A coronary narrowing < 50% was detected by coronary angiogram in 4 (5% of the remaining patients. Coronary angiogram was found to be normal in the remaining 26 patients (32% and these patients were evaluated as cardiac syndrome X (CSX known as microvascular angina (MA. Discussion: The findings showed that MPS is superior to coronary angiogram in the early diagnosis of myocardial perfusion disorders at the microvascular level. Therefore, we concluded that MPS should be the primary diagnostic tool to begin treatment before an anatomically large narrowing occurs in the coronaries.

  4. Detection of infarct size safety threshold for left ventricular ejection fraction impairment in acute myocardial infarction successfully treated with primary percutaneous coronary intervention.

    Science.gov (United States)

    Sciagrà, Roberto; Cipollini, Fabrizio; Berti, Valentina; Migliorini, Angela; Antoniucci, David; Pupi, Alberto

    2013-04-01

    In acute myocardial infarction (AMI) treated by primary percutaneous coronary intervention (PCI), there is a direct relationship between myocardial damage and consequent left ventricular (LV) functional impairment. It is however unclear whether there is a safety threshold below which infarct size does not significantly affect LV ejection fraction (EF). The aim of this study was to evaluate the relationship between infarct size and LVEF in AMI patients treated by successful PCI using a specific statistical approach to identify a possible safety threshold. Among patients with recent AMI submitted to perfusion gated single photon emission computed tomography (SPECT) to define the infarct size, the data of 427 subjects with sizable infarct size were considered. The relationship between infarct size and LVEF was analysed using a simple segmented regression (SSR) model and an iterative algorithm based on robust least squares (RLS) for parameter estimation. The RLS algorithm detected two break points in the SSR model, set at infarct size values of 11.0 and 51.5 %. Because the slope coefficients of the two extreme segments of the regression line were not significant, by constraining such segments to zero slope in the SSR model, the lower break point was identified at infarct size = 8 % and the upper one at 45 %. Using a rigorous statistical approach, it is possible to demonstrate that below a threshold of 8 % the infarct size apparently does not affect the LVEF and therefore a safety threshold could be set at this value. Furthermore, the same analysis suggests that the relationship between infarct size and LVEF impairment is lost for an infarct size > 45 %.

  5. Non-obstructive coronary artery disease assessed by coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Nielsen, L.; Bøtker, H. E.; Sorensen, H.

    2015-01-01

    Introduction: Coronary CT angiography (CTA) detects non-obstructive coronary artery disease (CAD) that may not be recognized by functional testing, but the prognostic impact is not well understood. This study aimed to compare the risk of myocardial infarction (MI) and all-cause mortality...... in patients without or with non-obstructive and obstructive CAD assessed by coronary CTA. Methods: Consecutive patients without known coronary artery disease (CAD) and with chest pain who underwent coronary CTA (>64-detector row) between January 2007 and December 2012 in the 10 centers participating...... in the Western Denmark Cardiac Computed Tomography Registry were included. The endpoints were 3-year MI or all-cause mortality. The coronary CTA result was defined as normal (0% luminal stenosis), non-obstructive CAD (1%-49% luminal stenosis) or obstructive CAD (>50% luminal stenosis; 1-vessel, 2-vessel, or 3...

  6. Evaluation of coronary artery disease by helical CT using retrospective ECG-gating

    International Nuclear Information System (INIS)

    Kawawa, Yoko

    2001-01-01

    The purpose of this study is to evaluate the usefulness of helical CT using retrospective ECG-gating for visualization of the coronary artery and detection of coronary artery disease. We performed a coronary artery phantom study and established this new application, with 1-mm collimation, 1-mm table increment, and 0.1-mm reconstruction (0.8 sec/rotation). Helical CT of 31 patients with 39 coronary artery diseases (34 coronary artery stenoses, 1 vasospastic angina, 1 coronary artery dissection, 1 coronary artery ectasia and 2 coronary artery aneurysms) was performed in a single breath hold and ECG-gating without and with intravenous injection of nonionic iodine contrast material. We selected the images which were not affected by cardiac motion from the reconstruction images, in order to visualize the coronary artery for detection of coronary artery disease. The coronary artery was well visualized in 32 out of 39 vessels (82%). A good visualization of the coronary artery was correlated with the heart rate. Further, in this well visualized group, coronary artery diseases were detected in 24 out of 31 cases (77%). One case of vasospastic angina was not included. It was difficult to detect coronary artery disease in cases of heavily calcified vessels or in the left circumflex artery. Helical CT using this retrospective ECG-gating is a useful noninvasive examination for evaluation of coronary artery disease. (author)

  7. Clinical application of combined detection of serum hs-CRP, GMP-140 and cTnI in patients with coronary heart diseases

    International Nuclear Information System (INIS)

    Qin Jibao; Wu Zhaozeng

    2010-01-01

    Objective: To explore the clinical significance of changes of serum hs-CRP, GMP-140 and cTnI levels in patients with coronary heart diseases. Methods: Serum GMP-140 (with RIA), cTnI (with ELISA) and hs-CRP (with immuno turbidity method) levels were determined in 91 patients with coronary heart diseases (42 SAP, 34UAP, 15AMI) and 35 controls. Results: Serum hs-CRP, GMP-140, cTnI levels in patients with coronary heart diseases were significantly higher than those in controls (P <0.01). Among the patients with of coronary heart diseases, the magnitude of changes of the levels of serum hs-CRP, GMP-140 and cTnI levels in AMI and UAP groups were significantly larger than those in SAP group (P < 0.05). Serum hs-CRP levels were positively correlated with serum GMP-140 and cTnI levels (r = 0.6214, 0.6023, P < 0.01). Conclusion: Serum hs-CRP, GMP140 and cTnI levels were closely related to the diseases process of coronary heart diseases and were of great clinical importance for assessment of the disease and outcome prediction. (authors)

  8. Head-to-head comparison of dipyridamole, dobutamine and pacing stress echocardiography for the detection of myocardial ischemia in an animal model of coronary artery stenosis

    Directory of Open Access Journals (Sweden)

    A. Schmidt

    2001-07-01

    Full Text Available To compare the sensitivity of dipyridamole, dobutamine and pacing stress echocardiography for the detection of myocardial ischemia we produced a physiologically significant stenosis in the left circumflex artery of 14 open-chest dogs (range: 50 to 89% reduction in luminal diameter. In each study, dobutamine (5 to 40 µg kg-1 min-1 in 3-min stages and pacing (20 bpm increments, each 2 min, up to 260 bpm were performed randomly, and then followed by dipyridamole (up to 0.84 mg/kg over 10 min. The positivity of stress echocardiography tests was quantitatively determined by a significant (P<0.05 reduction of or failure to increase absolute and percent systolic wall thickening in the stenotic artery supplied wall, as compared to the opposite wall (areas related to the left anterior descending artery. Systolic and diastolic frozen images were analyzed off-line by two blinded observers in the control and stress conditions. The results showed that 1 the sensitivity of dobutamine, dipyridamole and pacing stress tests was 57, 57 and 36%, respectively; 2 in animals with positive tests, the mean percent change of wall thickening in left ventricular ischemic segments was larger in the pacing (-19 ± 11% and dipyridamole (-18 ± 16% tests as compared to dobutamine (-9 ± 6% (P = 0.05, but a similar mean reduction of wall thickening was observed when this variable was normalized to a control left ventricular segment (area related to the left anterior descending artery (pacing: -16 ± 7%; dipyridamole: -25 ± 16%; dobutamine: -26 ± 10%; not significant, and 3 a significant correlation was observed between magnitude of coronary stenosis and left ventricular segmental dysfunction induced by ischemia in dogs submitted to positive stress tests. We conclude that the dobutamine and dipyridamole stress tests showed identical sensitivities for the detection of myocardial ischemia in this one-vessel disease animal model with a wide range of left circumflex artery

  9. The usefulness of contrast material injection at the dorsal vein of the hand in 64-detecter row helical CT coronary angiography

    International Nuclear Information System (INIS)

    Kawano, Youji; Yakabe, Kazuaki; Urata, Jungo; Eto, Miyuki; Yamaguchi, Hiroichiro

    2011-01-01

    In 315 cases of multi detector row CT (MDCT) coronary angiography contrast material were injected at the dorsal vein of the hand. Early 168 cases were used 80 ml of 370 mgI/ml contrast material and later 147 cases were used 350-480 mgI/kg contrast material. In all cases contrast material was injected by 4 ml/sec with post injection of 30-40 ml physiologic saline. The attenuation of RCA No.3 and other coronary arteries or coronary artery bypass graft (CABG) graft was measured. In later cases the usefulness of above 300 HU was 95.2%. In all cases the usefulness was 92.6%. (author)

  10. Assessment of myocardial collateral circulation by intracoronary injection of radioactive microspheres and selective coronary angiography

    International Nuclear Information System (INIS)

    Uhde, W.

    1986-01-01

    In 46 patients selective coronary angiography was performed followed by selective coronary perfusion scintigraphy and a comparative assessment was made of the contralateral coronary collateral circulation. Intracoronary injection of radioactively marked imcrospheres resulted in the detection of microcirculatory processes and made it possible to evaluate the relative efficiency of coronary collaterals. This in turn meant a low-risk supplement and extension of the findings of coronary angiography. This holds particularly true for the area of the left ventricular myocardium. (author)

  11. Integral diagnosis of coronary atherosclerosis by coronary multidetector computed tomography and by invasive coronary angiography

    International Nuclear Information System (INIS)

    Llerena Rojas, Luis Roberto; Llerena Rojas, Lorenzo D; Mendoza Rodriguez, Vladimir

    2013-01-01

    Coronary angiography by multidetector computed tomography (CMDCT) visualizes the wall and lumen of coronary arteries. Invasive coronary angiography (INVCA) only visualizes the arterial lumen but with better resolution

  12. The pacing stress test: thallium-201 myocardial imaging after atrial pacing. Diagnostic value in detecting coronary artery disease compared with exercise testing

    International Nuclear Information System (INIS)

    Heller, G.V.; Aroesty, J.M.; Parker, J.A.; McKay, R.G.; Silverman, K.J.; Als, A.V.; Come, P.C.; Kolodny, G.M.; Grossman, W.

    1984-01-01

    Many patients suspected of having coronary artery disease are unable to undergo adequate exercise testing. An alternate stress, pacing tachycardia, has been shown to produce electrocardiographic changes that are as sensitive and specific as those observed during exercise testing. To compare thallium-201 imaging after atrial pacing stress with thallium imaging after exercise stress, 22 patients undergoing cardiac catheterization were studied with both standard exercise thallium imaging and pacing thallium imaging. Positive ischemic electrocardiographic changes (greater than 1 mm ST segment depression) were noted in 11 of 16 patients with coronary artery disease during exercise, and in 15 of the 16 patients during atrial pacing. One of six patients with normal or trivial coronary artery disease had a positive electrocardiogram with each test. Exercise thallium imaging was positive in 13 of 16 patients with coronary artery disease compared with 15 of 16 patients during atrial pacing. Three of six patients without coronary artery disease had a positive scan with exercise testing, and two of these same patients developed a positive scan with atrial pacing. Of those patients with coronary artery disease and an abnormal scan, 85% showed redistribution with exercise testing compared with 87% during atrial pacing. Segment by segment comparison of thallium imaging after either atrial pacing or exercise showed that there was a good correlation of the location and severity of the thallium defects (r . 0.83, p . 0.0001, Spearman rank correlation). It is concluded that the location and presence of both fixed and transient thallium defects after atrial pacing are closely correlated with the findings after exercise testing

  13. Detection of coronary artery disease using 12-lead electrocardiogram and simultaneous dual myocardial imaging with iodine-123-β-methyl iodophenyl-pentadecanoic acid (BMIPP) and thallium-201 in patients with unstable angina

    International Nuclear Information System (INIS)

    Saitoh, Makoto; Hasegawa, Koh; Hasegawa, Kazuo; Kondoh, Teruo; Yanagawa, Tetsuo.

    1995-01-01

    We investigated the usefulness of 12-lead electrocardiogram and simultaneous single-photon emission computed tomography (SPECT) with 123 I-β-methyl iodophenyl-pentadecanoic acid (BMIPP) and thallium-201 ( 201 Tl) for detecting coronary artery disease (CAD) in 54 consecutive patients with unstable angina. Discordant BMIPP uptake was defined as less 123 I-BMIPP uptake than 201 Tl uptake in 123 I-BMIPP/ 201 Tl dual SPECT. In the detection of CAD, ischemic electrocardiographic change during anginal attack had high sensitivity and low specificity, while discordant BMIPP finding had low sensitivity and high specificity. In patients showing ST depression during anginal attack, discordant BMIPP uptake showed high sensitivity and high specificity for detecting CAD. In conclusion, both 12-lead electrocardiogram during anginal attack and discordant BMIPP uptake are useful in detecting CAD in patients with unstable angina. (author)

  14. Evaluation of the restenosis of coronary artery after percutaneous transluminal coronary angioplasty by three-dimensional coronary magnetic resonance angiography

    International Nuclear Information System (INIS)

    Arisaka, Hiraku

    2000-01-01

    Coronary magnetic resonance angiography (MRA) has been recently brought into clinical use, however, there has not been reports on the comparison with MRA and conventional contrast coronary angiography (CAG) in the detection of the localization and characteristics of coronary restenosis after percutaneous transluminal coronary angioplasty (PTCA). To assess the restenosis of coronary artery after PTCA, this study compared three-dimensional (3D) coronary MRA and CAG. One hundred three patients (76 males and 27 females, average age of 64.6±9.3 years old) were performed coronary MRA at 3-6 months after PTCA. The right coronary artery (RCA) group consist of 21 patients, the left anterior descending branch (LAD) 63 patients and the left circumflex branch (LCX) 19 patients. Coronary MRA was performed with the patients in supine position on a 1.5 T whole body scanner (MAGNETOM VISION, Siemens AG, Germany) using body array coil. The imaging technique used a 3-D gradient echo sequence with respiratory gating and fat suppression. The slice thickness was 2 mm, slab thickness 32 mm, a field of view of 300 mm and a matrix of 128 x 256. Other parameters were an echo time of 2.7 ms and a repetition time of 600 to 1100 msec. The measurement time of 1 imaging slab took 15 to 20 minutes depending on the patient's heart rate. The coronary arteries were reconstructed from the 3-D data set using a multiplanar reconstruction (MPR) technique. According to previous coronary MRA studies, a significant stenosis with a luminal reduction of ≥50% was assumed if a marked signal reduction or signal loss of a vessel segment was visible. In CAG, 57 of 103 patients showed restenosis. In coronary MRA, 37 of 103 patients demonstrated restenosis. The sensitivity, specificity, positive and negative predictive values were 64.9%, 100%, 100% and 69.6%, respectively. Predictive accuracy was 79.6%. Three-dimensional coronary MRA is useful in a noninvasive diagnostic method to evaluate the coronary

  15. Single coronary artery from right aortic sinus in a very elderly patient

    Directory of Open Access Journals (Sweden)

    Prashanth Panduranga

    2016-10-01

    Full Text Available In the absence of other associated cardiac anomalies, single coronary artery (SCA per se is a rare anomaly detected during coronary angiography or autopsy. Various types of SCA detected during coronary angiography have already been described. We herein report a type of SCA originating from the right sinus of Valsalva, with the right circumflex, left circumflex, and left anterior descending coronary arteries arising from the proximal part of the SCA in a 76-year-old female patient. She developed ventricular fibrillation during coronary angiography, which calls for caution while performing a coronary angiogram in such patients.

  16. Noninvasive Coronary Angiography with 64-Channel Multidetector Computed Tomography in Patients with Acute Coronary Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Ulimoen, G. R.; Gjoennaess, E.; Atar, D.; Dahl, T.; Stranden, E.; Sandbaek, G. (Dept. of Radiology, Dept. of Vascular Diagnosis and Research, and Division of Cardiology, Aker Univ. Hospital, Oslo (Norway))

    2008-12-15

    Background: Advances in computer tomography (CT) imaging technology in recent years have facilitated the possibility of noninvasive coronary angiography. Purpose: To compare the diagnostic accuracy of 64-channel multidetector computed tomography (MDCT) with conventional invasive coronary angiography (ICA) for the detection of significant coronary stenosis in patients with acute coronary syndrome (ACS). Material and Methods: MDCT was performed in 60 patients classified with non-ST-elevation infarction (NSTEMI) or unstable angina and scheduled for ICA within 3 days. The diagnostic accuracy of MDCT was evaluated using quantitative coronary angiography (QCA) as the gold standard. Results: 48 out of 60 patients had interpretable scans by both MDCT and ICA. On a segment-based analysis, 488 out of 665 segments with a diameter of =1.5 mm, as defined by QCA, were interpretable by MDCT. Sensitivity was 78%, specificity 87%, positive predictive value 47%, and negative predictive value 97% in detecting and excluding significant coronary stenosis, as defined with MDCT. On a per patient-based analysis, sensitivity was 89%, specificity 50%, positive predictive value 84%, and negative predictive value 60%. Conclusion: Limited diagnostic accuracy restricts the usefulness of coronary MDCT in patient groups with a high pretest probability of disease, such as in acute coronary syndrome.

  17. Noninvasive Coronary Angiography with 64-Channel Multidetector Computed Tomography in Patients with Acute Coronary Syndrome

    International Nuclear Information System (INIS)

    Ulimoen, G. R.; Gjoennaess, E.; Atar, D.; Dahl, T.; Stranden, E.; Sandbaek, G.

    2008-01-01

    Background: Advances in computer tomography (CT) imaging technology in recent years have facilitated the possibility of noninvasive coronary angiography. Purpose: To compare the diagnostic accuracy of 64-channel multidetector computed tomography (MDCT) with conventional invasive coronary angiography (ICA) for the detection of significant coronary stenosis in patients with acute coronary syndrome (ACS). Material and Methods: MDCT was performed in 60 patients classified with non-ST-elevation infarction (NSTEMI) or unstable angina and scheduled for ICA within 3 days. The diagnostic accuracy of MDCT was evaluated using quantitative coronary angiography (QCA) as the gold standard. Results: 48 out of 60 patients had interpretable scans by both MDCT and ICA. On a segment-based analysis, 488 out of 665 segments with a diameter of =1.5 mm, as defined by QCA, were interpretable by MDCT. Sensitivity was 78%, specificity 87%, positive predictive value 47%, and negative predictive value 97% in detecting and excluding significant coronary stenosis, as defined with MDCT. On a per patient-based analysis, sensitivity was 89%, specificity 50%, positive predictive value 84%, and negative predictive value 60%. Conclusion: Limited diagnostic accuracy restricts the usefulness of coronary MDCT in patient groups with a high pretest probability of disease, such as in acute coronary syndrome

  18. Coronary heart disease

    Science.gov (United States)

    Heart disease, Coronary heart disease, Coronary artery disease; Arteriosclerotic heart disease; CHD; CAD ... buildup of plaque in the arteries to your heart. This may also be called hardening of the ...

  19. Myocardial perfusion studies in coronary diseases

    International Nuclear Information System (INIS)

    Mut, Fernando

    1994-01-01

    For detecting in precocious form a coronary disease is necessary to apply a diagnostic techniques. The main considerations to be indicated in the present work are: physiological considerations, myocardial perfusion studies with radiotracers such as Talio 201, 99mTc, MIBI, 99mTc-Teboroxima, 99mTc-Fosfinas, instrumentation for obtain good images,proceedings protocols, studies interpretation, standards, SPECT, anomalies standards, coronary diseases

  20. Detection of patent ductus arteriosus with intraoperative transesophageal echocardiography in a patient undergoing closure of coronary artery to pulmonary artery fistula.

    Science.gov (United States)

    Miyata, Yuka; Hayashi, Yukio

    2017-01-01

    Coronary artery to pulmonary artery fistula is an unusual vascular anomaly, and the shunt ratio of this fistula is usually small. We report anesthetic management of a 55-year-old female with annuloaortic ectasia, aortic valve regurgitation, and coronary artery to pulmonary artery fistula undergoing radical repair. We calculated the left-to-right shunt ratio after placement of a pulmonary artery catheter and found that the ratio was unexpectedly high. Thus, we explored the presence of another shunt by intraoperative transesophageal echocardiography and found patent ductus arteriosus undiagnosed before operation. A combination of a pulmonary artery catheter and transesophageal echocardiography is useful to explore the presence of another shunt, such as patent ductus arteriosus during anesthesia.

  1. Noninvasive detection of coronary artery wall thickening with age in healthy subjects using high resolution MRI with beat-to-beat respiratory motion correction.

    Science.gov (United States)

    Scott, Andrew D; Keegan, Jennifer; Mohiaddin, Raad H; Firmin, David N

    2011-10-01

    To demonstrate coronary artery wall thickening with age in a small healthy cohort using a highly efficient, reliable, and reproducible high-resolution MR technique. A 3D cross-sectional MR vessel wall images (0.7 × 0.7 × 3 mm resolution) with retrospective beat-to-beat respiratory motion correction (B2B-RMC) were obtained in the proximal right coronary artery of 21 healthy subjects (age, 22-62 years) with no known cardiovascular disease. Lumen and outer wall (lumen + vessel wall) areas were measured in one central slice from each subject and average wall thickness and wall area/outer wall area ratio (W/OW) calculated. Imaging was successful in 18 (86%) subjects with average respiratory efficiency 99.3 ± 1.7%. Coronary vessel wall thickness and W/OW significantly correlate with subject age, increasing by 0.088 mm and 0.031 per decade respectively (R = 0.53, P = 0.024 and R = 0.48, P = 0.046). No relationship was found between lumen area and vessel wall thickness (P = NS), but outer wall area increased significantly with vessel wall thickness at 19 mm(2) per mm (P = 0.046). This is consistent with outward vessel wall remodeling. Despite the small size of our healthy cohort, using high-resolution MR imaging and B2B-RMC, we have demonstrated increasing coronary vessel wall thickness and W/OW with age. The results obtained are consistent with outward vessel wall remodeling. Copyright © 2011 Wiley-Liss, Inc.

  2. Prognostic implications of nonobstructive coronary plaques in patients with non-ST-segment elevation myocardial infarction: a multidetector computed tomography study

    DEFF Research Database (Denmark)

    Kristensen, Thomas S; Kofoed, Klaus F; Kühl, Jørgen T

    2011-01-01

    We sought to determine whether the amount of noncalcified plaque (NCP) in nonobstructive coronary lesions as detected by multidetector computed tomography (MDCT) was a predictor of future coronary events.......We sought to determine whether the amount of noncalcified plaque (NCP) in nonobstructive coronary lesions as detected by multidetector computed tomography (MDCT) was a predictor of future coronary events....

  3. Breath-hold two-dimensional MR angiography of coronary arteries. Comparison with conventional coronary angiography in ten cases

    International Nuclear Information System (INIS)

    Li Liwei; Zhang Wanshi; Liu Chaozhong; Lu Xiaoyan; Xu Jiaxing

    1997-01-01

    Purpose: To assess the diagnostic value of two-dimensional coronary magnetic resonance (MR) angiography in patients evaluated for ischemic heart disease. Materials and methods: Ten patients who underwent selective cardiac catheterization with coronary MR angiography were evaluated with two-dimensional coronary MR angiography. Coronary MR angiography was performed with breath-hold fat-suppressed ECG-gated Turbo-FLASH with K-space segmentation using a 1.5 T imager. Results: The left main coronary artery, proximal left anterior descending artery, circumflex artery and right coronary artery were demonstrated in all cases. Continuous segments (mean) of left anterior descending, circumflex and right coronary arteries visualized on MRA were 6.72 +- 3.16 cm, 3.67 +- 4.81 cm and 7.93 +- 3.12 cm respectively. The overall sensitivity for detection of hemodynamically significant coronary artery lesion (≥50%) was 62.5% respectively. Conclusion: Breath-hold two-dimensional coronary MR angiography was useful in showing relatively long segments of the main coronary arteries and also has potential in depicting hemodynamically significant coronary artery lesions

  4. Diagnostic value for coronary artery disease of ST depression and chest pain during dipyridamole loading

    International Nuclear Information System (INIS)

    Yonezawa, Yoshihiro; Doi, Yoshinori; Aono, Tadashi; Odawara, Hiroaki; Chikamori, Taishiro; Yamada, Mitsutoshi; Takata, Jun; Ozawa, Toshio; Hamashige, Naohisa.

    1991-01-01

    The diagnostic significance of both ST depression and chest pain during dipyridamole loading was assessed in 437 patients with coronary artery disease (CRD) who have received dipyridamole-loading thallium-201 myocardial scintigraphy and coronary arteriography. ST depression and chest pain were induced in 35% and 42%, respectively. ST depression occurred in 23% for one vessel disease, 55% for two-vessel disease, 67% for three-vessel disease, and 11% for non-significant disease. In the absence of myocardial infarction, it occurred in as many as 78% for two-vessel disease and 94% for three-vessel disease. ST depression had a sensitivity of 51% and a specificity of 89%. Chest pain had a lower specificity (77%), whereas the sensitivity remained the same (51%). In 42 (31%) of 134 patients with ST depression, coronary revascularization was necessary in the early stage. With a median follow up of 29 months, 3 patients (2%) died of cardiac events, and 12 (9%) had nonfatal cardiac complications. There was a significant correlation between reversible defects (RD) on myocardial scintigrams and ST depression; RD were seen in 81% of ST depression cases, and ST depression occurred in 51% of 210 RD cases. The more diseased vessels, the more frequently ST depression occurred in accordance with RD on myocardial scintigrams. Both ST depression and chest pain during dipyridamole loading tended to be associated with myocardial ischemia, suggesting the diagnostic value in CRD patients with limited exercise loading. RD on myocardial scintigrams was considered attributable to coronary steal phenomenon for multi-vessel disease and to the difference in the relative increase of the coronary flow for single vessel disease. (N.K.)

  5. The degree of coronary atherosclerosis as a marker of insulin resistance in non-diabetics

    Directory of Open Access Journals (Sweden)

    Parapid Biljana

    2010-01-01

    Full Text Available Introduction. The metabolic syndrome and its influence on coronary artery disease development and progression remains in focus of international research debates, while insulin resistance, which represents its core, is the key component of hypertension, dyslipidaemias, glucose intolerance and obesity. Objective. The aim of this study was to establish relationship between basal glucose and insulin levels, insulin sensitivity and lipid panel and the degree of coronary atherosclerosis in nondiabetic patients. Methods. The coronary angiograms were evaluated for the presence of significant stenosis, insulin sensitivity was assessed using the intravenous glucose tolerance test with a minimal model according to Bergman, while baseline glucose (G0, insulin (I0 and lipid panel measurements (TC, HDL, LDL, TG were taken after a 12-hour fasting. Results. The protocol encompassed 40 patients (19 men and 21 women treated at the Institute for Cardiovascular Diseases of the Clinical Centre of Serbia, Belgrade. All were non-diabetics who were divided into 3 groups based on their angios: Group A (6 patients, 15%, with no significant stenosis, Group B (18 patients, 45%, with a single-vessel disease and Group C (16 patients, 40%, with multi-vessel disease. Presence of lower insulin sensitivity, higher I0 and TC in the group of patients with a more severe degree of coronary atherosclerosis (insulin sensitivity: F=4.279, p=0.023, A vs. C p=0.012, B vs. C p=0.038; I0: F=3.461 p=0.042, A vs. B p=0.045, A vs. C p=0.013; TC: F=2.572, p=0.09, while no significant difference was found for G0, LDL, HDL and TG. Conclusion. Baseline insulinaemia, more precisely, fasting hyperinsulinaemia could be a good predictor of significant coronary atherosclerosis in non-diabetic patients, which enables a more elegant cardiometabolic risk assessment in the setting of everyday clinical practice.

  6. Three-Dimensional Respiratory-Gated Coronary Mr Angiography with Reference to X-Ray Coronary Angiography

    International Nuclear Information System (INIS)

    Ikonen, A. E. J.; Manninen, H. I.; Vainio, P.; Vanninen, R. L.; Matsi, P. J.; Soimakallio, S.; Hirvonen, T.P.J.; Hartikainen, J.E.K.

    2003-01-01

    Purpose: To assess the clinical value of three-dimensional coronary MR angiography (CMRA) in the detection of significant coronary artery stenosis using conventional X-ray angiography as the standard reference. Material and Methods: Sixty-nine patients underwent X-ray coronary angiography and CMRA because of suspected or previously diagnosed coronary artery disease. MRI was performed with a 1.5-T whole body imaging system using ECG-triggered 3D gradient echo sequence with retrospective navigator echo respiratory gating and fat suppression. Results: A total of 276 coronary artery segments were analyzed. The X-ray coronary angiography was normal in 22 patients. Significant proximal stenoses (exceeding 50%) or occlusions were present in 102 coronary artery segments. In all, 120 stenoses or occlusions were identified in CMRA. Sixteen percent of the coronary artery segments had to be excluded because of poor image quality. The overall sensitivity and specificity for MRA for identification of significant stenosis were 75% and 62%, respectively. CMRA correctly detected 89% of patients with at least one vessel disease, but 6 patients with coronary artery disease would have been missed. Conclusions: Because of the high data exclusion and false-negative case rate, CMRA with retrospective navigator echo triggering is at present not suitable as a clinical screening method in coronary artery disease

  7. Transesophageal echocardiography in the assessment of coronary arteries

    International Nuclear Information System (INIS)

    Adamek-Kosmider, A.; Kasprzak, J.; Kosmider, M.; Krzeminska-Pakula, M.

    1993-01-01

    The study was undertaken to assess the usefulness of TEE for evaluation of morphology and flow in coronary arteries. TEE (2D, spectral and color Doppler imaging) and coronary angiography were performed in 75 patients - 41 with valvular heart disease and 34 with ischemic heart disease. Proximal coronary artery stenosis was detected by coronarography in 11 pts (9-left main coronary artery, 2-right coronary artery). TEE visualization of proximal coronary arteries was possible in all pts. Echocardiographic features of artery stenosis were: the narrowing of the vessel in 2D image (9 pts), high flow velocity spectral Doppler (4 pts, mean 135 cm/s vs 55 cm/s in normal arteries) and mosaic, turbulent flow in color Doppler (10 pts). Sensitivity and specificity of TEE for coronary artery stenosis detection was respectively 81%/98% for 2D imaging and 90%/100% for color Doppler. TEE is a new, noninvasive and safe method for the evaluation of proximal coronary arteries. Detection of LMCA stenosis prior to atheterization may enhance the safety of coronary angiography. (author)

  8. CORONARY ARTERY FISTULA: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    MZ Chowdhury

    2007-01-01

    Full Text Available The prevalence of congenital abnormalities of coronary artery is about 2% of general population. Of these abnormalities 5% were related to coronary artery fistulae (CAF. We report a case of 66 year old diabetic woman who presented with retrosternal chest pain. Her chest pain was associated with exercise and progressively deteriorated over the last 6 months. Electrocardiography showed right bundle branch block and Echo Color Doppler revealed hypo kinetic lateral wall. Coronary angiogram detected nothing abnormal except an aberrant tortuous branch of left circumflex. CT scan revealed a calcified sac medial to the descended thoracic aorta. A contrast enhancement was also done. All these imaging impressions were suggestive of coronary-to-pulmonary fistula. Ibrahim Med. Coll. J. 2007; 1(1: 32-33

  9. Detection of restenosis after successful coronary angioplasty: Improved clinical decision making with use of a logistic model combining procedural and follow-up variables

    International Nuclear Information System (INIS)

    Renkin, J.; Melin, J.; Robert, A.; Richelle, F.; Bachy, J.L.; Col, J.; Detry, J.M.; Wijns, W.

    1990-01-01

    A prospective study of 111 patients who underwent repeat coronary angiography and exercise thallium-201 scintigraphy 6 +/- 2 months after complete revascularization by percutaneous transluminal coronary angioplasty was performed to assess whether clinical, procedure-related and postangioplasty exercise variables yield independent information for the prediction of angiographic restenosis after angioplasty. Complete revascularization was defined as successful angioplasty of one or more vessels that resulted in no residual coronary lesion with greater than 50% diameter stenosis. Restenosis was defined as a residual stenosis at the time of repeat angiography of greater than 50% of luminal diameter. Restenosis occurred in 40% of the patients. The 111 patients were randomly subdivided into a learning group (n = 84) and a testing group (n = 27). A logistic discriminant analysis was performed in the learning group and the logistic model was used to estimate a logistic probability of restenosis. This probability of restenosis was validated in the testing group. In the learning group of 84 patients univariate analysis of 39 factors revealed 8 factors related to restenosis: recurrence of angina (p less than 0.0001), postangioplasty abnormal finding on exercise thallium-201 scintigram (p less than 0.0001), exercise thallium-201 scintigram score (p less than 0.0001), difference between exercise and rest ST segment depression (p less than 0.001), postangioplasty exercise ST segment depression (p less than 0.001), absolute postangioplasty stenosis diameter (p less than 0.003), postangioplasty exercise work load (p less than 0.03) and postangioplasty exercise heart rate (p less than 0.05)

  10. Diagnostic Accuracy of Coronary CT Angiography for the Evaluation of Bioresorbable Vascular Scaffolds

    DEFF Research Database (Denmark)

    Collet, Carlos; Chevalier, Bernard; Cequier, Angel

    2018-01-01

    : 44 to 90) and a specificity of 82% (95% CI: 75 to 87). The diagnostic accuracy of coronary CTA was similar to coronary angiography in its ability to identify patients with a significant lesion based on the IVUS criteria (p = 0.75). CONCLUSIONS: Coronary CTA has good diagnostic accuracy to detect in-scaffold...... luminal obstruction and to assess luminal dimensions after BVS implantation. Coronary angiography and coronary CTA yielded similar diagnostic accuracy to identify the presence and severity of obstructive disease. Coronary CTA might become the method of choice for the evaluation of patients treated......OBJECTIVES: To assess the diagnostic accuracy of coronary computed tomography angiography (CTA) for bioresorbable vascular scaffold (BVS) evaluation. BACKGROUND: Coronary CTA has emerged as a noninvasive method to evaluate patients with suspected or established coronary artery disease...

  11. Anomalous origin of the left coronary artery from the pulmonary artery in children: diagnostic use of multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Quanli; Yao, Qiong; Hu, Xihong [Children' s Hospital of Fudan University, Department of Radiology, Shanghai (China)

    2016-09-15

    Anomalous origin of the left coronary artery from the pulmonary artery is a rare congenital anomaly. It is important to demonstrate the anomalous origin of the left coronary artery and its course before surgery. To explore the clinical diagnostic use of multidetector CT coronary angiography in detecting anomalous origin of the left coronary artery from the pulmonary artery in children. Nine children (2 boys, 7 girls) ages 2 months to 9 years with surgically confirmed anomalous origin of the left coronary artery from the pulmonary artery were studied. Clinical data, transthoracic echocardiography and CT coronary angiography images were retrospectively analyzed. Transthoracic echocardiography correctly diagnosed anomalous origin of the left coronary artery from the pulmonary artery in 7 of 9 patients (95% CI: 40-97%). CT coronary angiography revealed the anomalous origin of the left coronary artery in all children (95% CI: 66-100%). In a 4-year-old girl and a 9-year-old girl, CT coronary angiography showed dilation of the right coronary artery and collateral circulation between the right and the left coronary arteries. CT coronary angiography is a useful method to show the anomalous origin of the coronary artery in children with anomalous origin of the left coronary artery from the pulmonary artery, especially for patients in whom origin of the left coronary artery cannot be detected by transthoracic echocardiography. (orig.)

  12. Anomalous origin of the left coronary artery from the pulmonary artery in children: diagnostic use of multidetector computed tomography

    International Nuclear Information System (INIS)

    Shen, Quanli; Yao, Qiong; Hu, Xihong

    2016-01-01

    Anomalous origin of the left coronary artery from the pulmonary artery is a rare congenital anomaly. It is important to demonstrate the anomalous origin of the left coronary artery and its course before surgery. To explore the clinical diagnostic use of multidetector CT coronary angiography in detecting anomalous origin of the left coronary artery from the pulmonary artery in children. Nine children (2 boys, 7 girls) ages 2 months to 9 years with surgically confirmed anomalous origin of the left coronary artery from the pulmonary artery were studied. Clinical data, transthoracic echocardiography and CT coronary angiography images were retrospectively analyzed. Transthoracic echocardiography correctly diagnosed anomalous origin of the left coronary artery from the pulmonary artery in 7 of 9 patients (95% CI: 40-97%). CT coronary angiography revealed the anomalous origin of the left coronary artery in all children (95% CI: 66-100%). In a 4-year-old girl and a 9-year-old girl, CT coronary angiography showed dilation of the right coronary artery and collateral circulation between the right and the left coronary arteries. CT coronary angiography is a useful method to show the anomalous origin of the coronary artery in children with anomalous origin of the left coronary artery from the pulmonary artery, especially for patients in whom origin of the left coronary artery cannot be detected by transthoracic echocardiography. (orig.)

  13. Coronary anomalies in Pakistani children with tetralogy of fallot

    International Nuclear Information System (INIS)

    Hussain, I.; Patel, N.

    2010-01-01

    To determine coronary artery anomalies in tetralogy of Fallot in Pakistani children as seen on angiography. Study Design: Case series. Place and Duration of Study: The National Institute of Cardiovascular Diseases, Karachi, Pakistan from July 2006 to July 2007. Methodology: Children under 15 years of age with echocardiographic diagnosis of tetralogy of Fallot were included in the study. All patients had pre-operative cardiac catheterization and angiography. Coronary arteries were studied with a nonselective aortic root angiogram in standard cranially tilted left anterior oblique view. The frequency of a normal and an anomalous coronary was determined. Results: Of the 83 patients, 78% were male and had a mean age of 8.9 years. Their mean weight was 14.3 kilograms. Seventy six (91.6%) had a normal coronary anatomy while 7 (8.4%) patients had anomalous coronary arteries. Among the patients with coronary anomalies, the commonest was a single origin coronary artery in 04 (57.14%) cases. Three (42.86%) had an anomalous origin of left anterior descending artery from the right coronary artery. Conclusion: Coronary artery anomalies were detected in 8.4% of the cases with tetralogy of Fallot. Single origin coronary artery anomaly was the commonest anomaly. (author)

  14. An unreported type of coronary artery naomaly in congenitally corrected transposition of great arteries

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Min Kyu; Jeong, Yeon Joo; Lee, Gee Won; Lee, Nam Kyung; Choi, Jung Hyun; Lee, Ji Won [Medical Research Institute, Pusan National University Hospital, Busan (Korea, Republic of)

    2016-07-15

    Coronary artery variations are associated anomalies in 45% of congenitally corrected transposition of the great arteries (ccTGA) cases, and it is important to detect any coronary artery anomalies before cardiac surgery. We report a case of a 51-year-old woman with ccTGA and an unreported type of coronary artery anomaly.

  15. Use of postmortem coronary computed tomography angiography with water-insoluble contrast medium to detect stenosis of the left anterior descending artery in a case of sudden death.

    Science.gov (United States)

    Takahashi, Yoichiro; Sano, Rie; Takahashi, Keiko; Kominato, Yoshihiko; Takei, Hiroyuki; Kobayashi, Susumu; Shimada, Takehiro; Tokue, Hiroyuki; Awata, Sachiko; Hirasawa, Satoshi

    2016-03-01

    A 40-year-old man was found dead on a sidewalk in an expressway parking area one hour after he had entered the area on a motorcycle. A medicolegal autopsy was performed to reveal the cause of this sudden and unexpected death. Postmortem coronary CT angiography after introduction of 5% gelatin-barium emulsion as a radiopaque contrast medium into the heart demonstrated a significant arterial luminal filling defect in the left anterior descending (LAD) coronary artery. Macroscopic and microscopic examinations revealed that a thrombus had become deposited on ruptured plaque within the LAD artery, and that a small amount of the contrast medium was present between the thrombus and the vessel endothelium. These histological findings were consistent with incomplete occlusion of the LAD artery in the 3D reconstructed image. The cause of death in this case was definitively determined to be ischemic heart disease. Postmortem angiography played a role in screening of a vascular lesion that was subsequently verified by histology to have been responsible for sudden and unexpected death. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Prevalence of first-pass myocardial perfusion defects detected by contrast-enhanced dual-source CT in patients with non-ST segment elevation acute coronary syndromes

    Energy Technology Data Exchange (ETDEWEB)

    Schepis, Tiziano; Achenbach, Stephan; Marwan, Mohamed; Muschiol, Gerd; Ropers, Dieter; Daniel, Werner G.; Pflederer, Tobias [University of Erlangen, Department of Internal Medicine 2 (Cardiology), Erlangen (Germany)

    2010-07-15

    To investigate the prevalence and diagnostic value of first-pass myocardial perfusion defects (PD) visualised by contrast-enhanced multidetector computed tomography (MDCT) in patients admitted for a first acute coronary syndrome (ACS). Thirty-eight patients with non-ST segment elevation myocardial infarction (NSTEMI) or unstable angina (UA) and scheduled for percutaneous coronary intervention underwent dual-source CT immediately before catheterisation. CT images were analysed for the presence of any PD by using a 17-segment model. Results were compared with peak cardiac troponin-I (cTnI) and angiography findings. PD were seen in 21 of the 24 patients with NSTEMI (median peak cTnI level 7.07 ng/mL; range 0.72-37.07 ng/mL) and in 2 of 14 patients with UA. PD corresponded with the territory of the infarct-related artery in 20 out of 22 patients. In a patient-based analysis, sensitivity, specificity, negative and positive predictive values of any PD for predicting NSTEMI were 88%, 86%, 80% and 91%. Per culprit artery, the respective values were 86%, 75%, 80% and 83%. In patients with non-ST segment elevation ACS, first-pass myocardial PD in contrast-enhanced MDCT correlate closely with the presence of myocardial necrosis, as determined by increases in cTnI levels. (orig.)

  17. Circumflex coronary artery with aberrant origin and atherosclerosis

    International Nuclear Information System (INIS)

    Ozcan, E.; Bozlar, U.; Celik, T.; Tasar, M.

    2012-01-01

    Full text: Introduction: Circumflex (Cx) coronary artery congenital anomaly is reported to be less than 1% incidence. Coronary arteries with aberrant origin are more likely to have atherosclerosis according to some published literatures. Objectives and tasks: In this study we aim to present computed tomography (CT) angiography findings of a patient, who has Cx artery with aberrant origin and atherosclerotic. Materials and methods: 57-year-old woman without any symptoms who has risk factors to atherosclerosis was referred to our clinic for coronary CT angiography. Results: In CT angiography; we detected Cx coronary artery with aberrant origin (right sinus of valsalva) and retroaortic course. Also we saw intimal irregularities and calcified plaque causing severe narrowing in the proximal segment of artery. Right coronary and left anterior descendant arteries had mild atherosclerosis. Conclusion: Coroner CT angiography, which allows multiplanar imaging with high resolution, is an effective diagnostic tool for coronary artery disease, like not only congenital anomalies but also acquired atherosclerotic disease

  18. MRI in coronary artery disease

    International Nuclear Information System (INIS)

    Barkhausen, Joerg; Hunold, Peter; Waltering, Kai-Uwe

    2004-01-01

    Diagnosis of coronary artery disease (CAD) is a major challenge for medical imaging, because CAD is the leading cause of death in developed nations. Several non-invasive tests are used in clinical routine for the detection of CAD. However, due to limited sensitivity and specificity, the reliable diagnosis as well as the exclusion of CAD can only be established by catheter angiography. In patients with known CAD, therapeutic decisions require accurate information on myocardial function, ischemia and viability. Recently, magnetic resonance (MR) imaging has emerged as a non-invasive cardiac imaging technique that provides information on cardiac morphology, cardiac function, myocardial viability, and coronary morphology. This review discusses technical aspects and the clinical impact of different MR techniques. (orig.)

  19. Prevalence of Congenital Coronary Artery Anomalies and Variants in 2697 Consecutive Patients Using 64-Detector Row Coronary CTAngiography

    International Nuclear Information System (INIS)

    Shabestari, Abbas Arjmand; Akhlaghpoor, Shahram; Tayebivaljozi, Reza; Fattahi Masrour, Farzaneh

    2012-01-01

    Coronary artery anomalies are not common, but could be very serious. This study determines the frequency of coronary anomalies and normal variants by multi-detector-row computed tomography (MDCT). The results of cardiac MDCT study in 2697 consecutive patients were analyzed retrospectively. Acquisition was performed by a 64-detector row CT machine. Imaging results were assessed by experienced radiologists. Myocardial bridging was by far the most frequent coronary variant (n = 576, 21.3%). Eighty-three subjects (3.1%) showed other coronary anomalies and variants. Anomalies of origination and course of the left main coronary artery (LMCA) were detected in 1.09% of the subjects. The frequency of these anomalies in the right coronary artery (RCA), left circumflex artery (LCx), left anterior descending artery (LAD), posterior descending artery (PDA) and obtuse marginal (OM) artery were 1.24%, 0.33%, 0.1%, 0.07% and 0.03%, respectively. The single coronary pattern was seen in 0.18% and coronary fistulas in 0.07%. Based on the fact that coronary CT-angiography using MDCT can display different coronary anomalies, this study shows similar results to other reports on the subject. Future advances in the performance of CT machines will further improve the quality of CT-based cardiac imaging

  20. Cirsoid Aneurysm of Coronary Arteries Associated with Arterioventricular Fistula Evaluated by 64-Multidetector CT Coronary Angiography: Depiction of a Case

    International Nuclear Information System (INIS)

    Marrone, Gianluca; Mamone, Giuseppe; Milazzo, Mariapina; Caruso, Settimo; Baravoglia, Cesar Hernandez; Vitulo, Patrizio; Gridelli, Bruno; Luca, Angelo

    2009-01-01

    A female patient with severe pulmonary hypertension was admitted for lung transplant evaluation. As an incidental finding, the chest CT showed diffuse and dilated coronaries, not detected at previous echocardiography. A coronary CT angiography was then performed using a 64-multidetector computed tomography (MDCT) scanner to better evaluate the coronary tree. The images obtained after postprocessing demonstrated tremendously aneurysmatic and tortuous coronary arteries and the presence of a septal branch deepening into the myocardium and penetrating the right ventricle cavity, forming an abnormal arterioventricular fistula. A causal relation between the aneurysms and the fistula is suspected.

  1. Improved evaluation of the coronary collateral circulation measuring the regional blood flow with 133Xe

    International Nuclear Information System (INIS)

    Franz, N.; Strangfeld, D.; Romaniuk, P.; Heublein, B.

    1988-01-01

    In 40 patients with angina pectoris catheter diagnostic measurements of the myocardial flow were carried out after intracoronary application of 133 Xe at rest and after oral application of Curantyl in order to obtain a better evaluation of coronary collaterals. The results show relations between angiographically detected coronary collaterals and the reduced coronary reserve. A quantitative measurement of collaterals from the angiogram facilitates a more precise evaluation of the relation between coronary sclerosis and myocardial flow. (author)

  2. Coronary artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Koischwitz, D.; Harder, T.; Schuppan, U.; Thurn, P.

    1982-04-01

    Seven saccular coronary artery aneurysms have been demonstrated in the course of 1452 selective coronary artery angiograms. In six patients they were arterio-sclerotic; in one patient the aneurysm must have been congenital or of mycotic-embolic origin. The differential diagnosis between true aneurysms and other causes of vascular dilatation is discussed. Coronary artery aneurysms have a poor prognosis because of the possibility of rupture with resultant cardiac tamponade, or the development of thrombo-embolic myocardial infarction. These aneurysms can only be diagnosed by means of coronary angiography and require appropriate treatment.

  3. Indications for coronary angiography

    International Nuclear Information System (INIS)

    Kaltenbach, M.; Vallbracht, C.

    1985-01-01

    Today selective coronary angiography, introduced by Sones in 1957, is used as clinical routine for diagnosing morphological changes in the coronary arteries. Hitherto, more recent techniques such as digital subtraction angiography cannot provide comparable information. Strict criteria for its indication depending on possible therapeutic consequences, have to be applied, although the risk is low with a letality of 0.01 to 0.05 percent. Radionuclear investigations can be used as additional tool in selected cases. The careful indication for coronary angiography usually implies the possible need for coronary bypass graft surgery of balloon angioplasty. (orig./MG) [de

  4. Evaluation of combined near-IR spectroscopic (NIRS)-IVUS imaging as a means to detect lipid-rich plaque burden in human coronary autopsy specimens

    Science.gov (United States)

    Su, Jimmy L.; Grainger, Stephanie J.; Greiner, Cherry A.; Hendricks, Michael J.; Goode, Meghan M.; Saybolt, Matthew D.; Wilensky, Robert L.; Madden, Sean P.; Muller, James E.

    2016-02-01

    Intracoronary near-infrared spectroscopy (NIRS) can identify lipid in the coronary arteries, but lacks depth resolution. A novel catheter is currently in clinical use that combines NIRS with intravascular ultrasound (IVUS), which provides depth-resolved structural information via the IVUS modality. A measure designated as lipid-rich plaque burden (LRPB) has been proposed as a means to interpret the combined acoustic and optical information of NIRS-IVUS. LRPB is defined as the area created by the intersection of the NIRS lipid-rich arc with the corresponding IVUS-measured plaque burden. We determined the correlation in human coronary autopsy specimens between LRPB, a measure of lipid presence and extent available via intravascular imaging in patients, and the area of lipid-rich plaque as determined by the gold-standard of histology. Fifteen artery segments from 8 human autopsy hearts were imaged with the NIRS-IVUS system (TVC Imaging System, Infraredx Inc., Burlington, MA). Arteries were imaged in a specialty fixture that assured accurate co-registration between imaging and histology. The arteries were then fixed and divided into 2 mm blocks for histological staining. Pathological contouring of lipid-rich areas was performed on the stained thin sections for 54 lipid-rich blocks. Computation of LRPB was performed on transverse NIRS-IVUS frames corresponding to the histologic sections. The quantified LRPB was frequently higher than the lipid-rich plaque area determined by histology, because the region denoted by the EEL and lumen within the NIRS lipid-rich arc is not entirely comprised of lipid. Overall, a moderate to strong correlation (R = 0.73) was found between LRPB determined by NIRS-IVUS imaging and the lipid-rich plaque area determined by histology. LRPB, which can be measured in patients with NIRS-IVUS imaging, corresponds to the amount of lipid-rich plaque in a coronary artery. LRPB should be evaluated in prospective clinical trials for its ability to

  5. THE PLURAL LESION CORONARY AND CYTOKINES DISBALANCE IN PATIENTS WITH CORONARY ATHEROSCLEROSIS

    Directory of Open Access Journals (Sweden)

    Martynov AV

    2012-12-01

    Full Text Available The aim of the study was to examine the levels of the main pro-inflammatory and anti-inflammatory cytokines in patients with ischemic heart disease, and the study of the possible impact of persistent herpes virus infection plural lesion coronary arteries. A total of 57 patients (mean age 49,3 ± 3,7 years IHD s hemodynamically significant stenoses of the coronary vessels. Conducted virological examination, including the definition of hypertension HSV1, HSV2, HHV6, SMV, VZV and VEB immunofluorescent and cytokines ІL-1β, ІL-6 ІL-8, TNF by ELISA in serum. Found increased levels of proinflammatory cytokines ІL-1β, ІL-6 and FNPα of IHD patients who had hemodynamically significant stenoses of coronary vessels. ІL-6 level in patients with 2 or more significant coronary artery lesions exceeded the rate of patients with a damaged coronary artery in 1.67 TNFα, ІL-8 - 1.37 ІL-1β and 1.28 times respectively. In patients with plural coronary vascular damage was the most common combination of CMV, VEB and HHV6. Since CMV was detected in more than 60% of patients with injuries of two spacecraft and nearly 76% from three spacecraft, VEB was detected in 72% and 88%, respectively.

  6. Clinical perspective of coronary computed tomographic angiography in diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Chang, Hyuk-Jae; Chung, Namsik

    2011-01-01

    Since a 4-detector row coronary computed tomographic angiography (CCTA) was launched in 1998, CCTA has experienced rapid improvement of imaging qualities with the ongoing evolution of computed tomography (CT) technology. The diagnostic accuracy of CCTA to detect coronary artery stenosis is well established, whereas improvements are still needed to reduce the overestimation of coronary artery disease (CAD) and assess plaque composition. CCTA has been used to evaluate CAD in various clinical settings. For example, CCTA could be an efficient initial triage tool at emergency departments for patients with acute chest pain with low-to-intermediate risk because of its high negative predictive value. In patients with suspected CAD, CCTA could be a cost-effective alternative to myocardial perfusion imaging and exercise electrocardiogram for the initial coronary evaluation of patients with intermediate pre-test likelihood suspected CAD. However, in asymptomatic populations, there is a lack of studies that show an improved prognostic power of CCTA over other modalities. Therefore, the clinical use of CCTA to detect CAD for purposes of risk stratification in asymptomatic individuals should be discouraged. As CT technology evolves, CCTA will provide better quality coronary imaging and non-coronary information with lower radiation exposure. Future studies should cover these ongoing technical improvements and evaluate the prognostic power of CCTA in various clinical settings of CAD in large, well-designed, randomized trials. (author)

  7. Risk stratification in stable coronary artery disease is possible at cardiac troponin levels below conventional detection and is improved by use of N-terminal pro-B-type natriuretic peptide

    DEFF Research Database (Denmark)

    Lyngbæk, Stig; Winkel, Per; Gøtze, Jens P

    2014-01-01

    AIMS: Low prevalence of detectable cardiac troponin in healthy people and low-risk patients previously curtailed its use. With a new high-sensitive cardiac troponin assay (hs-cTnT), concentrations below conventional detection may have prognostic value, notably in combination with N-terminal pro......-B-type natriuretic peptide (NT-pro-BNP). METHODS AND RESULTS: Biomarker concentrations were determined from serum obtained at enrolment in the CLARICOR trial involving 4197 patients with stable coronary artery disease (CAD) followed for 2.6 years. Serum hs-cTnT was detectable (above 3 ng/l) in 78% and above...... the conventional 99th percentile (13.5 ng/l) in 23%. Across all levels of hs-cTnT there was a graded increase in the risk of cardiovascular death after adjustment for known prognostic indicators: hazard ratio (HR) per unit increase in the natural logarithm of the hs-cTnT level, 1.49; 95% confidence interval (CI...

  8. Coronary CT angiography in clinical triage of patients at high risk of coronary artery disease

    DEFF Research Database (Denmark)

    Kühl, J Tobias; Hove, Jens D; Kristensen, Thomas S

    2017-01-01

    OBJECTIVES: To test if cardiac computed tomography angiography (CCTA) can be used in the triage of patients at high risk of coronary artery disease. DESIGN: The diagnostic value of 64-detector CCTA was evaluated in 400 patients presenting with non-ST segment elevation myocardial infarction using...... invasive coronary angiography (ICA) as the reference method. The relation between the severity of disease by CCTA and a combined endpoint of death, re-hospitalization due to new myocardial infarction, or symptom-driven coronary revascularization was assessed. RESULTS: CCTA detects significant (>50...... in patients with high likelihood of coronary artery disease and could, in theory, be used to triage high risk patients. As many obstacles remain, including logistical and safety issues, our study does not support the use of CCTA as an additional diagnostic test before ICA in an all-comer NSTEMI population....

  9. Large coronary intramural hematomas

    DEFF Research Database (Denmark)

    Antonsen, Lisbeth; Thayssen, Per; Jensen, Lisette Okkels

    2015-01-01

    Isolated spontaneous coronary intramural hematoma is a unique subset of spontaneous coronary artery dissection that is characterized by a hemorrhage limited to the medial-adventitial layers, causing subsequent hematoma formation without visible intimal flaps. It is an infrequent and serious...... diagnostics and treatment strategy. Coronary intramural hematomas can also occur iatrogenically, as a complication to percutaneous coronary intervention (PCI). Coronary angiography (CAG) has limited diagnostic value in the absence of intimal dissections, and lesions are often angiographically ambiguous....... Intravascular ultrasound (IVUS) is an important diagnostic tool in establishing the correct diagnosis, as it provides a complete vessel wall assessment, and enables morphometric information regarding the magnitude and severity of the underlying hematoma. Due to the rarity of this clinical scenario...

  10. The ability of NT-proBNP to detect chronic heart failure and predict all-cause mortality is higher in elderly Chinese coronary artery disease patients with chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Fu S

    2013-04-01

    Full Text Available Shihui Fu, Leiming Luo, Ping Ye, Shuangyan Yi, Yuan Liu, Bing Zhu, Liang Wang, Tiehui Xiao, Yongyi Bai Department of Geriatric Cardiology, Chinese PLA General Hospital, Beijing, People's Republic of China Objective: To analyze the relationship between N-terminal pro-brain natriuretic peptide (NT-proBNP and renal function, and compare the ability and cut-off thresholds of NT-proBNP to detect chronic heart failure (CHF and predict mortality in elderly Chinese coronary artery disease (CAD patients with and without chronic kidney disease (CKD. Methods: The study included 999 CAD patients older than 60 years. The endpoint was all-cause mortality over a mean follow-up period of 417 days. Results: The median age was 86 years (range: 60–104 years, and the median NT-proBNP level was 409.8 pg/mL. CKD was present in 358 patients. Three hundred and six patients were positive for CHF. One hundred and ten CKD patients and 105 non-CKD patients died. Not only CKD, but also estimated glomerular filtration rate independently affected NT-proBNP. NT-proBNP detected CHF with a cut-off value of 298.4 pg/mL in non-CKD patients and a cut-off value of 435.7 pg/mL in CKD patients. NT-proBNP predicted death with a cut-off value of 369.5 pg/mL in non-CKD patients and a cut-off value of 2584.1 pg/mL in CKD patients. The NT-proBNP level was significantly related to the prevalence of CHF and all-cause mortality in CAD patients with and without CKD; this effect persisted after adjustment. The crude and multiple adjusted hazard ratios of NT-proBNP to detect CHF and predict mortality were significantly higher in patients with CKD compared with the remainder of the population. The addition of NT-proBNP to the three-variable and six-variable models generated a significant increase in the C-statistic. Conclusion: Amongst elderly Chinese CAD patients, there was an independently inverse association between NT-proBNP and renal function. With the higher cutoff points, NT

  11. Haptoglobin phenotypes as a risk factor for coronary artery disease ...

    African Journals Online (AJOL)

    Gehan Hamdy

    2014-04-22

    Apr 22, 2014 ... Recognition of diabetic individuals at greatest risk of developing coronary ..... Early detection of the disease and timely interventions can reduce the morbidity ..... additional risk factor of retinopathy in type 2 diabetes mellitus.

  12. Evaluation of hemodynamic significance of coronary fistulae. Diagnostic integration between coronary angiography and stress/rest myocardial scintigraphy

    International Nuclear Information System (INIS)

    Rubini, G.; Sebastiani, M.

    2000-01-01

    It is here reported on the importance of the integration of data obtained from digital coronary angiography and stress/rest 99m Tc sestamibi myocardial perfusion single photon emission tomography in evaluationing the hemodynamic significance of coronary arteriovenous fistulae. Coronary fistulae were detected with coronary angiography in 9 patients. All patients underwent clinical examination, trans thoracic echocardiography, stress electrocardiogram and stress/rest 99m Tc sestamibi myocardial perfusion single photon emission tomography. Stress/rest 99m Tc sestamibi myocardial perfusion single photon tomography and stress electrocardiogram showed stress-induced myocardial ischemia in 2 patients. The first patient with familial predisposition and risk factors for ischemic heart disease presented a mesocardic heart murmur on clinical examination. At stress ECG (125 Watt, 153 b/m max frequency 93%, arterial pressure 230 mmHg, max frequency pressure product 35200) ischemic alterations were recorded at the first minute of the second stage of the Bruce protocol. Coronary angiography detected a circumflex artery fistula in the coronary sinus. Stress/rest 99m Tc sestamibi myocardial perfusion single photon emission tomography for the evaluation of stress/rest perfusion detected a reversible perfusion defect of the proximal portion of the posterolateral and lateral walls, thus confirming the hemodynamic importance of the flow through the fistula during stress cycloergometric testing. In the second patient familial predisposition to ischemic heart disease and previous inferior wall myocardial infarction and non-significant stress ECG, coronary angiography identified a seclusive stenosis of the right coronary artery and anomaly between the anterior interventricular artery and the left pulmonary artery. The presence of the contrast medium in the left pulmonary artery identified a flow from the left ventricle to the left pulmonary artery. Good angiographic results were obtained

  13. Head-to-head comparison of peak supine bicycle exercise echocardiography and treadmill exercise echocardiography at peak and at post-exercise for the detection of coronary artery disease.

    Science.gov (United States)

    Peteiro, Jesús; Bouzas-Mosquera, Alberto; Estevez, Rodrigo; Pazos, Pablo; Piñeiro, Miriam; Castro-Beiras, Alfonso

    2012-03-01

    Supine bicycle exercise (SBE) echocardiography and treadmill exercise (TME) echocardiography have been used for evaluation of coronary artery disease (CAD). Although peak imaging acquisition has been considered unfeasible with TME, higher sensitivity for the detection of CAD has been recently found with this method compared with post-TME echocardiography. However, peak TME echocardiography has not been previously compared with the more standardized peak SBE echocardiography. The aim of this study was to compare peak TME echocardiography, peak SBE echocardiography, and post-TME echocardiography for the detection of CAD. A series of 116 patients (mean age, 61 ± 10 years) referred for evaluation of CAD underwent SBE (starting at 25 W, with 25-W increments every 2-3 min) and TME with peak and postexercise imaging acquisition, in a random sequence. Digitized images at baseline, at peak TME, after TME, and at peak SBE were interpreted in a random and blinded fashion. All patients underwent coronary angiography. Maximal heart rate was higher during TME, whereas systolic blood pressure was higher during SBE, resulting in similar rate-pressure products. On quantitative angiography, 75 patients had coronary stenosis (≥50%). In these patients, wall motion score indexes at maximal exercise were higher at peak TME (median, 1.45; interquartile range [IQR], 1.13-1.75) than at peak SBE (median, 1.25; IQR, 1.0-1.56) or after TME (median, 1.13; IQR, 1.0-1.38) (P = .002 between peak TME and peak SBE imaging, P peak TME (median, 5; IQR, 2-12) compared with peak SBE (median, 3; IQR, 0-8) or after TME (median, 2; IQR, 0-4) (P peak TME and peak SBE imaging, P peak TME, peak SBE, and post-TME echocardiography for CAD was 84%, 75%, and 60% (P = .001 between post-TME and peak TME echocardiography, P = .055 between post-TME and peak SBE echocardiography), with specificity of 63%, 80%, and 78%, respectively (P = NS) and accuracy of 77%, 77%, and 66%, respectively (P = NS). Peak TME

  14. Intraoperative echocardiographic imaging of coronary arteries and graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass.

    Science.gov (United States)

    Suematsu, Y; Takamoto, S; Ohtsuka, T

    2001-12-01

    No accepted approach exists for the intraoperative evaluation of the quality of coronary arteries and the technical adequacy of graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass. We assessed the accuracy of high-frequency epicardial echocardiography and power Doppler imaging in evaluating coronary arteries during coronary artery bypass grafting without cardiopulmonary bypass. To validate measurements of coronary arteries and graft anastomoses by high-frequency epicardial echocardiography and power Doppler imaging, we compared luminal diameters determined by these methods with diameters determined histologically in a study of off-pump coronary artery bypass grafting in 20 dogs. Technical errors were deliberately created in 10 grafts (stenosis group). The results of these animal validation studies showed that the maximum luminal diameters of coronary arteries and graft anastomoses measured by high-frequency epicardial echocardiography (HEE) and power Doppler imaging (PDI) correlated well with the histologic measurements: HEE = 1.027 x Histologic measurements + 0.005 (P anastomoses were examined intraoperatively by high-frequency epicardial echocardiography and power Doppler imaging, and luminal diameters determined by power Doppler imaging were compared with those determined by postoperative coronary angiography. The results demonstrated that graft anastomosis by power Doppler imaging correlated well with the angiographic measurements: PDI = 1.018 x Angiographic measurements - 0.106 (P anastomoses and can detect technical errors and inadequacies during coronary artery bypass grafting without cardiopulmonary bypass.

  15. Evaluation of myocardial bridging by coronary computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Marcio Vinicius Lins; Rabelo, Daniel Rocha; Siqueira, Maria Helena Albernaz, E-mail: marciovlbarros@uol.com.br [Hospital Mater Dei, Belo Horizonte, MG (Brazil); Garretto, Luiza Samarane; Paula, Marcela Mascarenhas De; Carvalho, Marina Oliveira; Alves, Marina Rangel Moreira Barros [Faculdade de Saude e Ecologia Humana (FASEH), Vespasiano, MG (Brazil)

    2013-01-15

    The myocardial bridge (MB) is defined as a segment of an epicardial coronary artery that has an intramural course in the myocardium. Although MB is clinically silent in most cases, has been associated with myocardial ischemia, arrhythmias and sudden death. Coronary conventional angiography is the gold standard for detection of MB, but is invasive and cannot be sufficiently sensitive compared to autopsy studies. Recently, multislice computed tomography of coronary arteries (MCTCA) has allowed the detection of coronary artery course, including PM. Objectives: to evaluate MB prevalence in patients with suspected coronary artery disease undergoing MCTCA and to evaluate the predictive value of this method at medium term. Methods: during the period 2008 to 2011, 498 consecutive patients were examined by TMC for the diagnosis of coronary artery disease, being conducted to evaluate the presence of BM and followed for a mean follow-up of 23 months for the occurrence of cardiovascular hard events (death, hospitalization or revascularization). Results: patients mean age was 55.3 ± 14.2, being male 71.1%. Among the patients, 7.6% (38 patients) showed MB. Main findings included angina pectoris in 40% and a positive stress test in 34%. 34.2% had atherosclerotic disease, and one patient had significant coronary stenosis. During follow-up, no patients showed adverse events. Conclusion: MCTCA is a noninvasive technique with high accuracy in anatomical evaluation of the coronary arteries and may be particularly useful to assess the incidence, location and morphology of myocardial bridging in vivo. (author)

  16. [Endarterectomy of the coronary arteries].

    Science.gov (United States)

    Fischer, V; Simkovic, I; Holoman, M; Verchvodko, P; Janotík, P; Galbánek, J; Hulman, M; Kostelnicák, J; Jurco, R; Slezák, J

    1992-02-01

    The authors analyze 50 patients with endarterectomy of the coronary arteries during the periods of 1972-1974 and 1988-1990. The results of endarterectomy of the right and left coronary artery provide evidence of its justification in indicated cases whereby contrary to some departments the results of endarterectomy of the left coronary artery are comparable with endarterectomy of the right coronary artery.

  17. Topographic association of angioscopic yellow plaques with coronary atherosclerotic plaque: assessment with quantitative colorimetry in human coronary artery autopsy specimens.

    Science.gov (United States)

    Ishibashi, Fumiyuki; Lisauskas, Jennifer B; Kawamura, Akio; Waxman, Sergio

    2008-01-01

    Yellow plaques seen during coronary angioscopy are thought to be the surrogates for superficial intimal lipids in coronary plaque. Given diffuse and heterogeneous nature of atherosclerosis, yellow plaques in coronaries may be seen as several yellow spots on diffuse coronary plaque. We examined the topographic association of yellow plaques with coronary plaque. In 40 non-severely stenotic ex-vivo coronary segments (average length: 52.2 +/- 3.1 mm), yellow plaques were examined by angioscopy with quantitative colorimetry. The segments were cut perpendicular to the long axis of the vessel at 2 mm intervals, and 1045 slides with 5 microm thick tissue for whole segments were prepared. To construct the plaque surface, each tissue slice was considered to be representative of the adjacent 2 mm. The circumference of the lumen and the lumen border of plaque were measured in each slide, and the plaque surface region was constructed. Coronary plaque was in 37 (93%) of 40 segments, and consisted of a single mass [39.9 +/- 3.9 (0-100) mm, 311.3 +/- 47.4 (0.0-1336.2) mm2]. In 30 (75%) segments, multiple (2-9) yellow plaques were detected on a mass of coronary plaque. The number of yellow plaques correlated positively with coronary plaque surface area (r = 0.77, P colorimetry, some of them are associated with lipid cores underneath thin fibrous caps, may be used to assess the extent of coronary plaque. Further research using angioscopy could be of value to study the association of high-risk coronaries with acute coronary syndromes.

  18. What do Polish interventional cardiologists know about indications and qualification for recanalisation of chronic total coronary artery occlusions?

    Science.gov (United States)

    Bryniarski, Krzysztof L; Zabojszcz, Michał; Dębski, Grzegorz; Marchewka, Jakub; Legutko, Jacek; Jankowski, Piotr; Siudak, Zbigniew; Żmudka, Krzysztof; Dudek, Dariusz; Bryniarski, Leszek

    2015-01-01

    Chronic total occlusions (CTO) are diagnosed in about 20% of patients with significant coronary artery disease. A disproportion between the high prevalence of CTOs and low rate of invasive treatment still exists. Technical difficulties, clinical uncertainties whether patients benefit from recanalisation, and a lack of knowledge of CTO may be responsible for this fact. To assess the knowledge of coronary arteries CTO among Polish interventional cardiologists. A self-designed questionnaire was used during two major Polish invasive cardiology workshops held in 2014. The study included 113 physicians, mostly cardiologists certified as independent operators. Average self-declared efficacy of CTO recanalisation was 63.5%. Most of the respondents agreed that the operator involved in the CTO recanalisation program should perform at least 30-50 procedures per year. Only 67% stated that before CTO revascularisation the evaluation of myocardial viability should be performed with dobutamine stress echocardiography as a preferred test. One third of the physicians agreed that CTO percutaneous coronary intervention (PCI) should not be performed directly after diagnostic angiography, and 51.5% believed that in patients with multi-vessel coronary artery disease PCI of CTO should be performed first. Multi-slice spiral computed tomography during the qualification and planning of the CTO revascularisation, in the opinion of 91% of the responders, should not be used before each procedure but could be useful in selected cases. Polish interventional cardiologists remains in compliance with current opinions about recanalisation of chronic coronary artery occlusions and the consensus of the EuroCTO Club, but there is still an unceasing need for further education and promotion of knowledge about CTOs.

  19. Improvement of myocardial perfusion reserve detected by cardiovascular magnetic resonance after direct endomyocardial implantation of autologous bone marrow cells in patients with severe coronary artery disease

    Directory of Open Access Journals (Sweden)

    Lau Chu-Pak

    2010-01-01

    Full Text Available Abstract Background Recent studies suggested that bone marrow (BM cell implantation in patients with severe chronic coronary artery disease (CAD resulted in modest improvement in symptoms and cardiac function. This study sought to investigate the functional changes that occur within the chronic human ischaemic myocardium after direct endomyocardial BM cells implantation by cardiovascular magnetic resonance (CMR. Methods and Results We compared the interval changes of left ventricular ejection fraction (LVEF, myocardial perfusion reserve and the extent of myocardial scar by using late gadolinium enhancement CMR in 12 patients with severe CAD. CMR was performed at baseline and at 6 months after catheter-based direct endomyocardial autologous BM cell (n = 12 injection to viable ischaemic myocardium as guided by electromechanical mapping. In patients randomized to receive BM cell injection, there was significant decrease in percentage area of peri-infarct regions (-23.6%, P = 0.04 and increase in global LVEF (+9.0%, P = 0.02, the percentage of regional wall thickening (+13.1%, P= 0.04 and MPR (+0.25%, P = 0.03 over the target area at 6-months compared with baseline. Conclusions Direct endomyocardial implantation of autologous BM cells significantly improved global LVEF, regional wall thickening and myocardial perfusion reserve, and reduced percentage area of peri-infarct regions in patients with severe CAD.

  20. Importance of the 31-p-nmr-spectroscopy for prediction and early detection of coronary heart disease in patients with diabetes mellitus type I

    International Nuclear Information System (INIS)

    Steinboeck, P.

    2001-06-01

    Microvascular abnormalities and dysfunction via thickening of the basement membrane are known to occur in diabetic patients. Myocardial high energy phosphates have been shown to be reduced by ischemia and alterations of the cardiac metabolism are the primary consequence of myocardial ischemia. The present study involved 30 male patients with diabetes mellitus type I and 36 healthy male volunteers as age-matched controls. Phosphorus-31-P-nuclear-magnetic-resonance-spectroscopic-imaging of the heart was performed in all subjects using a 1.5 Tesla whole-body-magnetic-resonance-scanner. The ratios of phosphocreatinine (PCr) to adenosine-triphosphate (ATP) were calculated. Moreover, echocardiographic evaluation and stress tests were performed in all individuals. The myocardium of patients with diabetes mellitus type I showed significantly decreased ratios of PCr/ATP compared with healthy controls. This study demonstrates for the first time a decreased ratio of PCr/ATP in the myocardium of patients with diabetes mellitus type I without a known history of coronary heart disease. (author)

  1. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  2. Automatic coronary calcium scoring using noncontrast and contrast CT images

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Guanyu, E-mail: yang.list@seu.edu.cn; Chen, Yang; Shu, Huazhong [Laboratory of Image Science and Technology, School of Computer Science and Engineering, Southeast University, No. 2, Si Pai Lou, Nanjing 210096 (China); Centre de Recherche en Information Biomédicale Sino-Français (LIA CRIBs), Nanjing 210096 (China); Key Laboratory of Computer Network and Information Integration, Southeast University, Ministry of Education, Nanjing 210096 (China); Ning, Xiufang; Sun, Qiaoyu [Laboratory of Image Science and Technology, School of Computer Science and Engineering, Southeast University, No. 2, Si Pai Lou, Nanjing 210096 (China); Key Laboratory of Computer Network and Information Integration, Southeast University, Ministry of Education, Nanjing 210096 (China); Coatrieux, Jean-Louis [INSERM-U1099, Rennes F-35000 (France); Labotatoire Traitement du Signal et de l’Image (LTSI), Université de Rennes 1, Campus de Beaulieu, Bat. 22, Rennes 35042 Cedex (France); Centre de Recherche en Information Biomédicale Sino-Français (LIA CRIBs), Nanjing 210096 (China)

    2016-05-15

    Purpose: Calcium scoring is widely used to assess the risk of coronary heart disease (CHD). Accurate coronary artery calcification detection in noncontrast CT image is a prerequisite step for coronary calcium scoring. Currently, calcified lesions in the coronary arteries are manually identified by radiologists in clinical practice. Thus, in this paper, a fully automatic calcium scoring method was developed to alleviate the work load of the radiologists or cardiologists. Methods: The challenge of automatic coronary calcification detection is to discriminate the calcification in the coronary arteries from the calcification in the other tissues. Since the anatomy of coronary arteries is difficult to be observed in the noncontrast CT images, the contrast CT image of the same patient is used to extract the regions of the aorta, heart, and coronary arteries. Then, a patient-specific region-of-interest (ROI) is generated in the noncontrast CT image according to the segmentation results in the contrast CT image. This patient-specific ROI focuses on the regions in the neighborhood of coronary arteries for calcification detection, which can eliminate the calcifications in the surrounding tissues. A support vector machine classifier is applied finally to refine the results by removing possible image noise. Furthermore, the calcified lesions in the noncontrast images belonging to the different main coronary arteries are identified automatically using the labeling results of the extracted coronary arteries. Results: Forty datasets from four different CT machine vendors were used to evaluate their algorithm, which were provided by the MICCAI 2014 Coronary Calcium Scoring (orCaScore) Challenge. The sensitivity and positive predictive value for the volume of detected calcifications are 0.989 and 0.948. Only one patient out of 40 patients had been assigned to the wrong risk category defined according to Agatston scores (0, 1–100, 101–300, >300) by comparing with the ground

  3. Selective coronary scintigraphy

    International Nuclear Information System (INIS)

    Gambini, D.-J.

    1975-01-01

    Isotopic techniques occupy a leading place amongst examinations practicable on coronary patients because of their reliability and the safety and simplicity of their use. The present work reviews the possible applications of selective coronary scintigraphy in pathology. After a brief discussion on scintigraphy, isotopic techniques for myocardium research, coronarography and other methods to study local myocardium perfusion the theoretical bases for the use of the exploration are studied, the techniques and methods employed are reported and the results discussed. Coronary scintigraphy consists of selective injection in the two coronary arteries previously catheterized during a coronarography, of two different populations of microspheres labelled with two physically short-lived indicators: 15μ 99m Tc-labelled serumalbumin microspheres, 10 to 15μ In-labelled siderophiline microspheres. Various studies have shown the complete harmlessness of the exploration when certain precautions are taken regarding the size and number of the spheres. The microspheres disperse into the downstream arterial territory proportionally to the number of capillaries present in the different parts of the irrigated region, and are temporarily stopped in the precapillaries. The preparation of the different images needed to interpret the Face and OAG examination for the left coronary, then for the right coronary, is carried out at the end of the coronarography and lasts about 45 minutes. It is also possible by selective injection in the aorta-coronary bridges to judge their functional condition by observation of the regions they irrigate. 56 patients of the Necker hospital cardiological clinic have been examined [fr

  4. Congenital coronary artery fistula

    International Nuclear Information System (INIS)

    Oh, Yeon Hee; Kim, Hong; Zeon, Seoc Kil; Suh, Soo Jhi

    1986-01-01

    Congenital coronary artery fistula (CCAF) is communication of a coronary artery or its main branch with one of the atria or ventricles, the coronary sinus, the superior vena cava, or the pulmonary artery. In Korean peoples, only 4 cases of the CCAF were reported as rare as worldwide and authors want to report another case of CCAF, confirmed by operation. 10-year-old girl shows a fistula between sinus node artery of the right coronary artery and right atrium on root aortogram with left-to-right shunt and Qp/Qs=1.58, in which simple ligation of the sinus node artery from right coronary artery was performed. All of the 5 Korean CCAF (4 were previously reported and 1 of authors) were originated from right coronary artery, and of which 4 were opening into right ventricle and 1 of authors were into right atrium. Associated cardiac anomaly was noted in only 1 case as single coronary artery. Ages were from 9 months of age to 10 years old and no adult left case were found. 3 were female and 2 were male patients.

  5. Effect of Heart Rate and Coronary Calcification on the Diagnostic Accuracy of the Dual-Source CT Coronary Angiography in Patients with Suspected Coronary Artery Disease

    International Nuclear Information System (INIS)

    Meng, Lingdong; Cui, Lianqun; Cheng, Yuntao; Wu, Xiaoyan; Tang, Yuansheng; Wang, Yong; Xu, Fayun

    2009-01-01

    To evaluate the diagnostic accuracy of a dual-source computed tomography (DSCT) coronary angiography, with a particular focus on the effect of heart rate and calcifications. One hundred and nine patients with suspected coronary disease were divided into 2 groups according to a mean heart rate ( 400). Next, the effect of heart rate and calcification on the accuracy of coronary artery stenosis detection was analyzed by using an invasive coronary angiography as a reference standard. Coronary segments of less than 1.5 mm in diameter in an American Heart Association (AHA) 15-segment model were independently assessed. The mean heart rate during the scan was 71.8 bpm, whereas the mean Agatston score was 226.5. Of the 1,588 segments examined, 1,533 (97%) were assessable. A total of 17 patients had calcium scores above 400 Agatston U, whereas 50 had heart rates ≥ 70 bpm. Overall the sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) for significant stenoses were: 95%, 91%, 65%, and 99% (by segment), respectively and 97%, 90%, 81%, and 91% (by artery), respectively (n = 475). Heart rate showed no significant impact on lesion detection; however, vessel calcification did show a significant impact on accuracy of assessment for coronary segments. The specificity, PPV and accuracy were 96%, 80%, and 96% (by segment), respectively for an Agatston score less than 100% and 99%, 96% and 98% (by artery). For an Agatston score of greater to or equal to 400 the specificity, PPV and accuracy were reduced to 79%, 55%, and 83% (by segment), respectively and to 79%, 69%, and 85% (by artery), respectively. The DSCT provides a high rate of accuracy for the detection of significant coronary artery disease, even in patients with high heart rates and evidence of coronary calcification. However, patients with severe coronary calcification (> 400 U) remain a challenge to diagnose

  6. Incremental value of regional wall motion analysis immediately after exercise for the detection of single-vessel coronary artery disease. Study by separate acquisition, dual-isotope ECG-gated single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Yoda, Shunichi; Sato, Yuichi; Matsumoto, Naoya; Tani, Shigemasa; Takayama, Tadateru; Uchiyama, Takahisa; Saito, Satoshi

    2005-01-01

    Although the detection of wall motion abnormalities gives incremental value to myocardial perfusion single-photon emission computed tomography (SPECT) in the diagnosis of extensive coronary artery disease (CAD) and high-grade single-vessel CAD, whether or not it is useful in the diagnosis of mild, single-vessel CAD has not been studied previously. Separate acquisition, dual isotope electrocardiogram (ECG)-gated SPECT was performed in 97 patients with a low likelihood of CAD (Group 1) and 46 patients with single-vessel CAD (Group 2). Mild CAD was defined by stenosis of 50-75% (Group 2a, n=22) and moderate to severe CAD was defined by stenosis ≥76% (Group 2b, n=24). Myocardial perfusion and wall motion were graded by a 5 point-scale, 20-segment model. The sensitivity of myocardial perfusion alone was 50% for Group 2a, 83% for Group 2b and 67% for Group 2 as a whole. The overall specificity was 90%. When the wall motion analysis was combined, the sensitivity was increased to 82% in Group 2a and 92% in Group 2b. The ability to detect a wall motion abnormality immediately after exercise gives incremental diagnostic value to myocardial perfusion SPECT in the identification of mild, single-vessel CAD. (author)

  7. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  8. Comparative effectiveness of coronary artery bypass grafting (CABG) surgery and percutaneous coronary intervention (PCI) in elderly patients with diabetes.

    Science.gov (United States)

    Shah, Ruchit; Yang, Yi; Bentley, John P; Banahan, Benjamin F

    2016-11-01

    To compare the relative effectiveness of coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI) among elderly patients with diabetes regarding acute myocardial infarction (AMI), stroke, repeat revascularization, and all-cause mortality. A retrospective cohort study was conducted using the 2006-2008 5% national sample of Medicare claims data. Elderly (≥65 years) beneficiaries with at least two claims of diabetes separated by ≥30 days and who had at least one inpatient claim for multi-vessel CABG or PCI between 1 July 2006 and 30 June 2008 were identified. The date of beneficiary's first CABG or PCI was defined as the index date. All patients were followed from the index date to 31 December 2008 for outcomes. CABG and PCI patients were 1:1 matched on propensity scores and index dates. Cox proportional hazards models were used to compare postoperative outcomes between patients undergoing CABG versus PCI. The matched sample consisted of 4430 patients (2215 in each group). The Cox proportional hazards models showed that, compared to patients undergoing PCI, CABG was associated with a lower risk of postoperative AMI (hazard ratio [HR]: 0.494; 95% CI: 0.396-0.616; p < .0001), repeat revascularization (HR: 0.194; 95% CI: 0.149-0.252; p < .0001), the composite outcome (HR: 0.523; 95% CI: 0.460-0.595; p < .0001), and all-cause mortality (HR: 0.775; 95% CI: 0.658-0.914; p = .0024); postoperative risk of stroke was not significantly different between the two groups (HR: 0.965; 95% CI: 0.812-1.148; p = .691). CABG appears to be the preferred revascularization strategy for elderly patients with diabetes and coronary heart disease. However, this result should be interpreted considering study limitations, for example, several patient clinical variables and physician-related factors which may affect procedure outcomes are not available in the data. Clinical decisions should be individualized considering all patient- and physician

  9. Visualization of the coronary arteries. 6

    International Nuclear Information System (INIS)

    Koch, M.; Von Schulthess, G.K.

    1991-01-01

    Since MRI is very sensitive to motion, flow and perfusion, in addition to its ability to depict detailed morphology, it has many excellent advantages as a tool for studying vascular structures. These include its noninvasive nature, excellent and to a large degree user adjustable contrast between flowing blood and cardiovascular structures, and the ability to produce direct images in any plane. The coronary arteries can be identified in their proximal parts when imaging is done using sections perpendicular to the aortic root, more distally located portions are detected inconsistently and should not be confounded with cardiac veins. With gradient-echo imaging and MR angiograpic (MRA) methods the coronaries can be visualized well, because their is a positive, rather than a negative vascular contrast as found in spin-echo (SE) images. With regard to coronary artery imaging, to date MRA does not challenge the primary role of conventional coronary angiography. Conventional angiograms have superior spatial resolution and are less sensitive to degradation by flow disturbances. Current MRA is a purely experimental procedure and MRI of the coronary vessels is a research endeavour. (author). 32 refs.; 7 figs

  10. Computed tomography with multidetectors in the diagnosis of coronary stenosis

    International Nuclear Information System (INIS)

    Lombo, Bernardo; Carvajal, Codos A; Tafur, Monica; Gomez, Rafael

    2007-01-01

    Coronary angiography that uses multislice spiral computed tomography is a noninvasive technique for the detection of coronary stenosis that has had significant improvements in recent years. The introduction of 16 and 64 row scanners, the development of synchronized scanning electrocardiogram and better reconstruction techniques permit higher spatial and temporal resolution that allows better identification of coronary plaques and significant obstructive coronary lesions. In the next years Multislice spiral computed tomography will continue maturing and it will become a useful non invasive diagnostic imaging tool for the diagnosis of coronary disease and will be integrated to the cardiologic management protocols. Our next review will be focused on the basic and technical aspects of the scanner, diagnostic performance and clinical applications of this new technology

  11. Ability of combined Near-Infrared Spectroscopy-Intravascular Ultrasound (NIRS-IVUS) imaging to detect lipid core plaques and estimate cap thickness in human autopsy coronary arteries

    Science.gov (United States)

    Grainger, S. J.; Su, J. L.; Greiner, C. A.; Saybolt, M. D.; Wilensky, R. L.; Raichlen, J. S.; Madden, S. P.; Muller, J. E.

    2016-03-01

    The ability to determine plaque cap thickness during catheterization is thought to be of clinical importance for plaque vulnerability assessment. While methods to compositionally assess cap integrity are in development, a method utilizing currently available tools to measure cap thickness is highly desirable. NIRS-IVUS is a commercially available dual imaging method in current clinical use that may provide cap thickness information to the skilled reader; however, this is as yet unproven. Ten autopsy hearts (n=15 arterial segments) were scanned with the multimodality NIRS-IVUS catheter (TVC Imaging System, Infraredx, Inc.) to identify lipid core plaques (LCPs). Skilled readers made predictions of cap thickness over regions of chemogram LCP, using NIRS-IVUS. Artery segments were perfusion fixed and cut into 2 mm serial blocks. Thin sections stained with Movat's pentachrome were analyzed for cap thickness at LCP regions. Block level predictions were compared to histology, as classified by a blinded pathologist. Within 15 arterial segments, 117 chemogram blocks were found by NIRS to contain LCP. Utilizing NIRSIVUS, chemogram blocks were divided into 4 categories: thin capped fibroatheromas (TCFA), thick capped fibroatheromas (ThCFA), pathological intimal thickening (PIT)/lipid pool (no defined cap), and calcified/unable to determine cap thickness. Sensitivities/specificities for thin cap fibroatheromas, thick cap fibroatheromas, and PIT/lipid pools were 0.54/0.99, 0.68/0.88, and 0.80/0.97, respectively. The overall accuracy rate was 70.1% (including 22 blocks unable to predict, p = 0.075). In the absence of calcium, NIRS-IVUS imaging provided predictions of cap thickness over LCP with moderate accuracy. The ability of this multimodality imaging method to identify vulnerable coronary plaques requires further assessment in both larger autopsy studies, and clinical studies in patients undergoing NIRS-IVUS imaging.

  12. Incremental value of B-type natriuretic peptide for detection and risk reclassification of obstructive coronary artery disease on computed tomography angiography.

    Science.gov (United States)

    Kawabe, Masayuki; Sato, Akira; Hoshi, Tomoya; Endo, Masae; Yoshida, Ikuo; Aonuma, Kazutaka

    2017-04-01

    B-type natriuretic peptide (BNP) is well known to increase as a result of left ventricular systolic dysfunction and is a useful diagnostic marker for heart failure. The purpose of this study was to assess the incremental value of BNP for predicting obstructive coronary artery disease (CAD) on computed tomography angiography (CTA) in patients with suspected CAD. This was an observational analysis of patients with stable CAD undergoing CTA in our institution between April 2008 and June 2014. Consecutive 947 patients with suspected CAD who underwent 64-slice CTA were enrolled. Obstructive CAD was defined as more than 50% luminal narrowing. We divided the patients into 2 groups according to median BNP value (20.3pg/ml). Duke clinical score for obstructive CAD was calculated for each patient. Obstructive CAD was found in 273 (28.0%) patients. Median follow-up period was 37 months (interquartile range 21-55 months). Kaplan-Meier curves showed that BNP above median was significantly associated with major adverse cardiac events (p=0.001). In multivariable logistic analysis, patients with BNP above median were associated with the presence of obstructive CAD, as compared with BNP below median [odds ratio, 2.55; 95% confidence interval (CI), 1.79-3.63; pvalue of the Duke clinical score and BNP, the predictive value of the Duke clinical score [area under the curve (AUC), 0.714] could be increased by BNP (AUC 0.745 for the combined model; prisk score. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  13. Coronary plaque morphology on multi-modality imagining and periprocedural myocardial infarction after percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Akira Sato

    2016-06-01

    Full Text Available Percutaneous coronary intervention (PCI may be complicated by periprocedural myocardial infarction (PMI as manifested by elevated cardiac biomarkers such as creatine kinase (CK-MB or troponin T. The occurrence of PMI has been shown to be associated with worse short- and long-term clinical outcome. However, recent studies suggest that PMI defined by biomarker levels alone is a marker of atherosclerosis burden and procedural complexity but in most cases does not have independent prognostic significance. Diagnostic multi-modality imaging such as intravascular ultrasound, optical coherence tomography, coronary angioscopy, near-infrared spectroscopy, multidetector computed tomography, and magnetic resonance imaging can be used to closely investigate the atherosclerotic lesion in order to detect morphological markers of unstable and vulnerable plaques in the patients undergoing PCI. With the improvement of technical aspects of multimodality coronary imaging, clinical practice and research are increasingly shifting toward defining the clinical implication of plaque morphology and patients outcomes. There were numerous published data regarding the relationship between pre-PCI lesion subsets on multi-modality imaging and post-PCI biomarker levels. In this review, we discuss the relationship between coronary plaque morphology estimated by invasive or noninvasive coronary imaging and the occurrence of PMI. Furthermore, this review underlies that the value of the multimodality coronary imaging approach will become the gold standard for invasive or noninvasive prediction of PMI in clinical practice.

  14. Acute Coronary Syndrome

    Science.gov (United States)

    ... heart cells are dying. An electrocardiogram (ECG or EKG) can diagnose an acute coronary syndrome by measuring ... Privacy Policy Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  15. Coronary artery fistula

    Science.gov (United States)

    ... PA: Elsevier Saunders; 2015:chap 84. Friedman AH, Silverman NH. Congenital anomalies of the coronary arteries. In: ... provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, Isla Ogilvie, PhD, and the ...

  16. Coronary Artery Disease

    DEFF Research Database (Denmark)

    Christiansen, Morten Krogh

    2017-01-01

    A family history of coronary artery disease (CAD) is an important risk factor for adverse coronary events, in particular if the disease has an early onset. The risk of CAD is influenced by genetic and environmental factors with a greater genetic contribution earlier in life. Through recent years......), and to characterize and quantify subclinical atherosclerosis in their relatives. Furthermore, the aim was to explore the impact of common genetic risk variants on the age of onset, familial clustering and disease severity. In study I, 143 patients with early- onset CAD were recruited from the Western Denmark Heart...... Registry and risk factor control was evaluated. The study revealed that risk factors are common in early-onset CAD and that a large room for risk factor improvement remains. In study II, we used coronary computed tomography angiography to compare the coronary plaque burden and characteristics between 88...

  17. Auxetic coronary stent endoprosthesis

    DEFF Research Database (Denmark)

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar

    2014-01-01

    BACKGROUND: Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit...... a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable...... for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. METHODS: The auxetic design...

  18. Acute coronary syndrome

    Science.gov (United States)

    ... Have plenty of fruits, veggies, whole grains, and lean meats. Try to limit foods high in cholesterol ... et al. 2014 AHA/ACC guideline for the management of patients with non-ST-elevation acute coronary ...

  19. Coronary hemodynamics in vasospastic angina

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Kubota, Shinobu; Serizawa, Takashi; Nakase, Emiko; Kawai, Ichiro; Saito, Takayuki

    1991-01-01

    To evaluate the coronary circulation and myocardial perfusion dynamics, we performed left coronary digital subtraction angiography (DSA) in 35 patients with vasospastic angina. The left coronary circulation time (CCT) measured from the proximal left coronary artery to the coronary sinus was 5.77±0.86 sec, and the left epicardial conducting artery transmission time (CAT) measured from the proximal left coronary artery to the apical area was 2.65±0.82 sec in normal controls. The CCT and CAT were significantly prolonged in patients with vasospastic angina, indicating that the coronary peripheral vascular resistance is probably greater after the cessation of nitrates and Ca ++ -antagonists. After the intracoronary injection of ergonovine malate, the CCT was slightly shortened, but the apical T 1/2 was significantly prolonged in patients with vasospastic angina. This suggested that coronary vasospasm is present not only in the epicardial arteries but also in coronary arteries with peripheral resistance. These phenomena were not observed in normal controls. We performed left coronary DSA after conventional left coronary cineangiography. When the CCT exceeded 6.7 sec, we considered that the coronary circulation was significantly impaired. We concluded that the coronary DSA is very useful for evaluating abnormal coronary circulation in patients with vasospastic angina during myocardial perfusion. (author)

  20. Gender differences in risk profile and outcome of Middle Eastern patients undergoing percutaneous coronary intervention.

    Science.gov (United States)

    Jarrah, Mohamad I; Hammoudeh, Ayman J; Al-Natour, Dalal B; Khader, Yousef S; Tabbalat, Ramzi A; Alhaddad, Imad A; Kullab, Susan M

    2017-02-01

    To determine the gender differences in cardiovascular risk profile and outcomes among patients undergoing percutaneous coronary intervention (PCI). Methods: In a prospective multicenter study of consecutive Middle Eastern patients managed with PCI from January 2013 to February 2014 in 12 tertiary care centers in Amman and Irbid, Jordan. Clinical and coronary angiographic features, and major cardiovascular events were assessed for both genders from hospital stay to 1 year. Results: Women comprised 20.6% of 2426 enrolled patients, were older (mean age 62.9 years versus 57.2 years), had higher prevalence of hypertension (81% versus 57%), diabetes (66% versus 44%), dyslipidemia (58% versus 46%), and obesity (44% versus 25%) compared with men, p less than 0.001. The PCI for ST-segment elevation myocardial infarction was indicated for fewer women than men (23% versus 33%; p=0.001). Prevalence of single or multi-vessel coronary artery disease was similar in women and men. More women than men had major bleeding during hospitalization (2.2% versus 0.6%; p=0.003) and at one year (2.5% versus 0.9%; p=0.007). There were no significant differences between women and men in mortality (3.1% versus 1.7%) or stent thrombosis (2.1% versus 1.8%) at 1 year. Conclusion: Middle Eastern women undergoing PCI had worse baseline risk profile compared with men.Except for major bleeding, no gender differences in the incidence of major adverse cardiovascular events were demonstrated.

  1. Multislice computed tomographic coronary angiography: experience in a UK centre

    International Nuclear Information System (INIS)

    Morgan-Hughes, G.J.; Marshall, A.J.; Roobottom, C.A.

    2003-01-01

    AIM: To evaluate the technique of coronary angiography with retrospectively electrocardiogram (ECG)-gated four-slice helical computed tomography (CT). MATERIALS AND METHODS: Within 1 month of undergoing routine day-case diagnostic coronary angiography, 30 consecutive patients also underwent retrospectively ECG-gated multislice CT coronary angiography. This enabled direct comparison of seven segments of proximal and mid-coronary artery for each patient by two blinded assessors. Each segment of coronary artery from the multislice CT image was evaluated initially for 'assessability' and those segments deemed assessable were subsequently investigated for the presence or absence of a significantly (n=70%) stenotic lesion. RESULTS: Overall 68% of proximal and mid-coronary artery segments were assessable. The sensitivity and specificity of four-slice CT coronary angiography in assessable segments for detecting the presence or absence (n=70%) of stenoses were 72 and 86%, respectively. These results correspond to a positive predictive value of 53% and a 93% negative predictive value. If the 32% of non-assessable segments are added into the calculation then the sensitivity and specificity fall to 49 and 66%, respectively. CONCLUSION: Although multislice CT coronary angiography is a promising technique, the overall assessability and diagnostic accuracy of four-slice CT acquisition is not sufficient to justify routine clinical use. Further, evaluation should investigate the benefit of the reduction in temporal and spatial resolution offered by 16 and 32 slice acquisition

  2. Coronary tortuosity: a long and winding road.

    NARCIS (Netherlands)

    Zegers, E.S.; Meursing, B.T.J.; Oude Ophuis, A.J.M.

    2007-01-01

    Coronary tortuosity is a phenomenon often encountered by cardiologists performing coronary angiography. The aetiology and clinical importance of coronary tortuosity are still unclear. Coronary tortuosity without fixed atherosclerotic stenosis in patients with angina pectoris and an abnormal exercise

  3. Coronary Artery Anomalies in Animals

    Directory of Open Access Journals (Sweden)

    Brian A. Scansen

    2017-04-01

    Full Text Available Coronary artery anomalies represent a disease spectrum from incidental to life-threatening. Anomalies of coronary artery origin and course are well-recognized in human medicine, but have received limited attention in veterinary medicine. Coronary artery anomalies are best described in the dog, hamster, and cow though reports also exist in the horse and pig. The most well-known anomaly in veterinary medicine is anomalous coronary artery origin with a prepulmonary course in dogs, which limits treatment of pulmonary valve stenosis. A categorization scheme for coronary artery anomalies in animals is suggested, dividing these anomalies into those of major or minor clinical significance. A review of coronary artery development, anatomy, and reported anomalies in domesticated species is provided and four novel canine examples of anomalous coronary artery origin are described: an English bulldog with single left coronary ostium and a retroaortic right coronary artery; an English bulldog with single right coronary ostium and transseptal left coronary artery; an English bulldog with single right coronary ostium and absent left coronary artery with a prepulmonary paraconal interventricular branch and an interarterial circumflex branch; and a mixed-breed dog with tetralogy of Fallot and anomalous origin of all coronary branches from the brachiocephalic trunk. Coronary arterial fistulae are also described including a coronary cameral fistula in a llama cria and an English bulldog with coronary artery aneurysm and anomalous shunting vessels from the right coronary artery to the pulmonary trunk. These examples are provided with the intent to raise awareness and improve understanding of such defects.

  4. Calcified Plaque of Coronary Artery: Factors Influencing Overestimation of Coronary Artery Stenosis on Coronary CT Angiography

    International Nuclear Information System (INIS)

    Kim, Mok Hee; Kim, Yun Hyeon; Choi, Song; Seon, Hyun Ju; Jeong, Gwang Woo; Park, Jin Gyoon; Kang, Heoung Keun; Ko, Joon Seok

    2010-01-01

    To assess the influence of calcified plaque characteristics on the overestimation of coronary arterial stenosis on a coronary CT angiography (CCTA). The study included 271 coronary arteries with calcified plaques identified by CCTA, and based on 928 coronary arteries from 232 patients who underwent both CCTA and invasive coronary angiography (ICA). Individual coronary arteries were classified into two groups by agreement based on the degree of stenosis from each CCTA and ICA: 1) group A includes patients with concordant CCTA and ICA results and, 2) group B includes patients with an overestimation of CCTA compared to ICA. Parameters including total calcium score, calcium score of an individual coronary artery, calcium burden number of an individual coronary artery, and the density of each calcified plaque (calcium score / number of calcium burden) for each individual coronary artery were compared between the two groups. Of the 271 coronary arteries, 164 (60.5%) were overestimated on CCTA. The left anterior descending artery (LAD) had a significantly low rate of overestimation (47.1%) compared to the other coronary arteries (p=0.001). No significant differences for total calcium score, calcium score of individual coronary artery, and the density of each calcified plaque from individual coronary arteries between two groups was observed. However, a decreasing tendency for the rate of overestimation on CCTA was observed with an increase in calcium burden of individual coronary arteries (p<0.05). The evaluation of coronary arteries suggests that the degree of coronary arterial stenosis had a tendency to be overestimated by calcified plaques on CCTA. However, the rate of overestimation for the degree of coronary arterial stenosis by calcified plaques was not significantly influenced by total calcium score, calcium score of individual coronary artery, and density of each calcified plaque

  5. Absence of Bacteria on Coronary Angioplasty Balloons from Unselected Patients

    DEFF Research Database (Denmark)

    Hansen, Gorm Mørk; Nilsson, Martin; Nielsen, Claus Henrik

    2015-01-01

    Periodontitis is a chronic, bacterially-induced inflammatory disease of the tooth-supporting tissues, which may result in transient bacteremia and a systemic inflammatory response. Periodontitis is associated with coronary artery disease independently of established cardiovascular risk factors...... and purification steps, and demonstration of sensitivity levels of 25-125 colony forming units (CFU), we did not detect bacterial DNA from any of the coronary angioplasty balloons. A subsequent questionnaire indicated that the prevalence of periodontitis in the study cohort was at least 39.5%. Although coronary...

  6. Exertional headache and coronary ischemia despite normal electrocardiographic stress testing.

    Science.gov (United States)

    Cutrer, F Michael; Huerter, Karina

    2006-01-01

    Exertional headaches may under certain conditions reflect coronary ischemia. We report the case of a patient seen in a neurology referral practice whose exertional headaches, even in the face of two normal electrocardiographic stress tests and in the absence of underlying chest pain were the sole symptoms of coronary ischemia as detected by Tc-99m Sestamibi testing SPECT stress testing. Stent placement resulted in complete resolution of headaches. Exertional headache in the absence of chest pain may reflect underlying symptomatic coronary artery disease (CAD) even when conventional electrocardiographic stress testing does not indicate ischemia.

  7. Advanced 2-dimensional quantitative coronary angiographic analysis for prediction of fractional flow reserve in intermediate coronary stenoses.

    Science.gov (United States)

    Opolski, Maksymilian P; Pregowski, Jerzy; Kruk, Mariusz; Kepka, Cezary; Staruch, Adam D; Witkowski, Adam

    2014-07-01

    The widespread clinical application of coronary computed tomography angiography (CCTA) has resulted in increased referral patterns of patients with intermediate coronary stenoses to invasive coronary angiography. We evaluated the application of advanced quantitative coronary angiography (A-QCA) for predicting fractional flow reserve (FFR) in intermediate coronary lesions detected on CCTA. Fifty-six patients with 66 single intermediate coronary lesions (≥ 50% to 80% stenosis) on CCTA prospectively underwent coronary angiography and FFR. A-QCA including calculation of the Poiseuille-based index defined as the ratio of lesion length to the fourth power of the minimal lumen diameter (MLD) was performed. Significant stenosis was defined as FFR ≤ 0.80. The mean FFR was 0.86 ± 0.09, and 18 lesions (27%) were functionally significant. FFR correlated with lesion length (R=-0.303, P=0.013), MLD (R=0.527, P44%, and >69%, respectively (maximum negative predictive value of 94% for MLA, maximum positive predictive value of 58% for diameter stenosis). The Poiseuille-based index was the most accurate (C statistic 0.86, sensitivity 100%, specificity 71%, positive predictive value 56%, and negative predictive value 100%) predictor of FFR ≤ 0.80, but showed the lowest interobserver agreement (intraclass correlation coefficient 0.37). A-QCA might be used to rule out significant ischemia in intermediate stenoses detected by CCTA. The diagnostic application of the Poiseuille-based angiographic index is precluded by its high interobserver variability.

  8. 64 multislice computed tomography imaging of coronary artery origin anomalies in adults

    International Nuclear Information System (INIS)

    Dai Qinyi; Lv Biao; Zhang Zhaoqi

    2006-01-01

    Objective: To assess the value of 64 multislice computed tomography (64 MSCT) in the evaluation of coronary artery origin anomalies in adults. Methods: Nine hundred and seventy eight Chinese adult patients undergone coronary artery CT angiography (CTA) between March and July 2005 at Anzhen hospital were reviewed for this study. Results: In consecutive 978 patients, 64 MSCT identified (3.07%) with an anomalous origin of the coronary artery, in 30 patients including anomalous origin of the right coronary artery (RCA) in 9 patients, the left coronary artery (LCA)in 7 patients, both RCA and LCA in 2 patients, the absence of the left circumflex artery (LCX) in 1 patient and anomalous origin of the branch of coronary artery in 11 patients. Conclusion: Noninvasive 64 multislice computed tomography can detect the anomalous origin of the coronary artery with high resolution. (authors)

  9. Distal coronary hemoperfusion during percutaneous transluminal coronary angioplasty

    NARCIS (Netherlands)

    Muinck, Ebo Derk de

    1994-01-01

    In this thesis several aspects of passive and active coronary perfusion during coronary angioplasty are investigated. The autoperfusion balloon catheters that were evaluated are the Stack® and the RX-60® catheters (Advanced Cardiovascular Systems, inc., Santa Clara, California, U.S.A). The coronary

  10. Nuclear cardiology and coronary surgery

    DEFF Research Database (Denmark)

    Eckardt, R.; Andersen, L.I.; Hesse, B.

    2008-01-01

    Rising age, repeated percutaneous coronary revascularizations, and co-morbidity such as overweight, diabetes, and hypertension, characterize a change over the last 20-30 years in coronary patients referred to coronary artery bypass grafting (CABG). This patient group represents a great part of to...

  11. Coronary CT angiography using prospective ECG triggering. High diagnostic accuracy with low radiation dose

    International Nuclear Information System (INIS)

    Arnoldi, E.; Ramos-Duran, L.; Abro, J.A.; Costello, P.; Zwerner, P.L.; Schoepf, U.J.; Nikolaou, K.; Reiser, M.F.

    2010-01-01

    The purpose of this study was to evaluate the diagnostic performance of coronary CT angiography (coronary CTA) using prospective ECG triggering (PT) for the detection of significant coronary artery stenosis compared to invasive coronary angiography (ICA). A total of 20 patients underwent coronary CTA with PT using a 128-slice CT scanner (Definition trademark AS+, Siemens) and ICA. All coronary CTA studies were evaluated for significant coronary artery stenoses (≥50% luminal narrowing) by 2 observers in consensus using the AHA-15-segment model. Findings in CTA were compared to those in ICA. Coronary CTA using PT had 88% sensitivity in comparison to 100% with ICA, 95% to 88% specificity, 80% to 92% positive predictive value and 97% to 100% negative predictive value for diagnosing significant coronary artery stenosis on per segment per patient analysis, respectively. Mean effective radiation dose-equivalent of CTA was 2.6±1 mSv. Coronary CTA using PT enables non-invasive diagnosis of significant coronary artery stenosis with high diagnostic accuracy in comparison to ICA and is associated with comparably low radiation exposure. (orig.) [de

  12. 64-slice spiral CT coronary angiography with prospective electrocardiogram-gating: an initial study

    International Nuclear Information System (INIS)

    Yuan Xuchun; Wang Xianzhu; Liao Wenling; Chen Qin; Deng Huiyi

    2008-01-01

    Objective: To evaluate the feasibility of prospective electrocardiogram (ECG)-gating computed tomography coronary angiography (CTCA). Methods: Sixty patients with suspected or known coronary artery disease underwent 64-slice CTCA using prospective ECG-gating. Multi-planar reconstruction ( MPR), curved-planar reconstruction (CPR), maximum intensity projection (MIP) and volume rendering (VR) were used to demonstrate the coronary arteries. The image quality and radiation dose was evaluated. Results: The mean effective radiation dose was (2.7±0.2) mSv. 93.3% (720/772) segments of all coronary arteries were of diagnostic image quality, 44.2% (341/772)was classified as excellent and 49.1% (379/772)was good. Non-diagnostic coronary segments were found in 6.7% (52/772) of all coronary arteries. There were 5(8.3%) cases with severe coronary stenosis(>75%) or occlusion, 17 (28.4%) cases with moderate stenosis (50%-75%), 18 (30.0%) cases with mild stenosis (<50% )or irregular lumen, 20(33.3%) cases with normal coronary, artery. Conclusion: With a low radiation dose, prospective electrocardiogram (ECG)-gated coronary 64-MSCT angiography has a good potential for the detection of coronary stenosis, especially for excluding coronary artery disease. (authors)

  13. Angiographic signs of acute thrombosis of the coronary artery in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Zingerman, L.S.; Belozerov, G.E.; Topchiyan, G.S.; Zvereva, T.V.

    1988-01-01

    The results of a retrospective analysis of coronoragrams of 57 patients with myocardial infarction in whom intracoronary throbolytic therapy in the first 24 h of the desease resulted in the recanalization of the occluded infarction-related coronary artery indicating the presence of an obturating thrombus in its lumen are presented. The authors described signs detected during prior coronarography (before radioendovascular recanalization) in patients with acute coronary occlision due to thrombosis of the coronary artery. The most characteristic ones were a ''severed branch'' symptom in the early arterial phase (86%), the stump of the occluded coronary artery in the form of an ''increased contrast bar'' in the late arterial phase (78.9%), the symptom of ''retention'' of a contrast substance in the stump of the coronary artery in the parenchymatous and venous phases of coronography (64%), low detectability of collateral inflows in the distal bed of the acutely occluded coronary artery

  14. Anomalous origin of right coronary artery from left coronary sinus.

    Science.gov (United States)

    Hamzeh, Gadah; Crespo, Alex; Estarán, Rafael; Rodríguez, Miguel A; Voces, Roberto; Aramendi, José I

    2008-08-01

    Anomalous aortic origin of the coronary arteries is uncommon but clinically significant. Manifestations vary from asymptomatic patients to those who present with angina pectoris, myocardial infarction, heart failure, syncope, arrhythmias, and sudden death. We describe 4 patients, aged 34 to 59 years, who were diagnosed with right coronary artery arising from the left sinus of Valsalva, confirmed by coronary angiography, which was surgically repaired. Three patients presented dyspnea and angina, and one with acute myocardial infarction. At operation, the right coronary artery was dissected at the take-off from the intramural course, and reimplanted into the right sinus of Valsalva. There was no mortality. One patient had associated coronary artery disease that required stent placement postoperatively. This reimplantation technique provides a good physiological and anatomical repair, eliminates a slit-like ostium, avoids compression of the coronary artery between the aorta and the pulmonary artery, and gives superior results to coronary artery bypass grafting or the unroofing technique.

  15. Quantitative thallium-201 single-photon emission computed tomography during maximal pharmacologic coronary vasodilation with adenosine for assessing coronary artery disease

    International Nuclear Information System (INIS)

    Nishimura, S.; Mahmarian, J.J.; Boyce, T.M.; Verani, M.S.

    1991-01-01

    The diagnostic value of maximal pharmacologic coronary vasodilation with intravenously administered adenosine in conjunction with thallium-201 single-photon emission computed tomography (SPECT) for detection of coronary artery disease was investigated in 101 consecutive patients who had concomitant coronary arteriography. Tomographic images were assessed visually and from computer-quantified polar maps of the thallium-201 distribution. Significant coronary artery disease, defined as greater than 50% luminal diameter stenosis, was present in 70 patients. The sensitivity for detecting patients with coronary artery disease using quantitative analysis was 87% in the total group, 82% in patients without myocardial infarction and 96% in those with prior myocardial infarction; the specificity was 90%. The sensitivity for diagnosing coronary artery disease in patients without infarction with single-, double-and triple-vessel disease was 76%, 86% and 90%, respectively. All individual stenoses were identified in 68% of patients with double-vessel disease and in 65% of those with triple-vessel disease. The extent of the perfusion defects, as quantified by polar maps, was directly related to the extent of coronary artery disease. In conclusion, quantitative thallium-201 SPECT during adenosine infusion has high sensitivity and specificity for diagnosing the presence of coronary artery disease, localizing the anatomic site of coronary stenosis and identifying the majority of affected vascular regions in patients with multivessel involvement

  16. Coexistence of Single Coronary Artery Anomaly and Aortic Arch Anomaly

    Directory of Open Access Journals (Sweden)

    Yilmaz Omur Otlu

    2014-03-01

    Full Text Available A 74-year-old male patient was admitted to our hospital for evaluation of recent onset atypical chest pain. His medical history included hypertension, dislipidemia and smoking. Physical examination was unremarkable. The resting electrocardiogram was demonstrated biphasic T waves on lateral derivations. Transthoracic echocardiography showed normal left and right ventricular dimensions and functions. Coronary angiography was planned for the patient. First, right transradial approach tried; but guidewire could not be advanced to ascendig aorta. Coronary angiography was performed through the right femoral artery. Multiple attempts to cannulate the left coronary ostium were unsuccessful. The right coronary artery cannulated from its normal ostium in the right sinus of Valsalva. After a very short common main stem, the artery divided into a right coronary artery, and separate left anterior descending artery and circumflex artery (Figure A. The coronary arteries were normal without any significant stenosis and any extrinsic compression. An aortic root injection confirmed the absence of left coronary ostium. Also, a retroesophageal right subclavian artery originating from the left aortic arch (arteria lusoria was detected as the last branch of aortic arch on contrast enhanced computerized tomography (Figure B-C. The patient discharged with medical teraphy.

  17. Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); M-C. Morice (Marie-Claude); A.P. Kappetein (Arie Pieter); A. Colombo (Antonio); D.R. Holmes Jr (David); M.J. Mack (Michael); E. Stahle (Elisabeth); T.E. Feldman (Ted); M.J.B.M. van den Brand (Marcel); E.J. Bass (Eric); N. van Dyck (Nic); K. Leadly (Katrin); K.D. Dawkins (Keith); F.W. Mohr (Friedrich)

    2009-01-01

    textabstractBACKGROUND Percutaneous coronary intervention (PCI) involving drug-eluting stents is increasingly used to treat complex coronary artery disease, although coronary-artery bypass grafting (CABG) has been the treatment of choice historically. Our trial compared PCI and CABG for treating

  18. Radiation exposure to patient's skin during percutaneous coronary intervention for various lesions, including chronic total occlusion

    International Nuclear Information System (INIS)

    Suzuki, Shigeru; Furui, Shigeru; Kohtake, Hiroshi; Yokoyama, Naoyuki; Kozuma, Ken; Yamamoto, Yoshito; Isshiki, Takaaki

    2006-01-01

    Radiation skin injuries have been reported as a result of various procedures, so in the present study the patients' entrance skin dose (ESD) during percutaneous coronary intervention (PCI) was evaluated. ESDs were assessed during 97 procedures (13 for chronic total occlusion (CTO), 14 for multivessel stenoses, 22 for single-vessel multiple stenoses, and 48 for single stenosis). The patients wore jackets that had 48 or 52 radiosensitive indicators placed on the back during the PCI procedures, with 8 other indicators placed on both upper arms. After the procedure, the color of the indicators was analyzed with a color measuring instrument, and the patients' ESDs were calculated from the color difference of the indicators. The average maximum ESDs of the patients were 4.5±2.8 Gy (median: 4.6 Gy) for CTO, 2.3±0.7 Gy (median: 2.4 Gy) for multi-vessel stenoses, 1.8±1.0 Gy (median: 1.5 Gy) for single-vessel multiple stenoses, and 1.4±0.9 Gy (median: 1.2 Gy) for single stenosis. Skin injury can occur during PCI, especially for CTO, so it is important to estimate each patient's ESD and attempt to reduce it. (author)

  19. The importance of left ventricular function for long-term outcome after primary percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Tio René A

    2008-02-01

    Full Text Available Abstract Background In the present study we sought to determine the long-term prognostic value of left ventricular ejection fraction (LVEF, assessed by planar radionuclide ventriculography (PRV, after ST-elevation myocardial infarction (STEMI treated with primary percutaneous coronary intervention (PPCI. Methods In total 925 patients underwent PRV for LVEF assessment after PPCI for myocardial infarction before discharge from the hospital. PRV was performed with a standard dose of 500 Mbq of 99mTc-pertechnetate. Average follow-up time was 2.5 years. Results Mean (± SD age was 60 ± 12 years. Mean (± SD LVEF was 45.7 ± 12.2 %. 1 year survival was 97.3 % and 3 year survival was 94.2 %. Killip class, multi vessel-disease, previous cardiovascular events, peak creatin kinase and its MB fraction, age and LVEF proved to be univariate predictors of mortality. When entered in a forward conditional Cox regression model age and LVEF were independent predictors of 1 and 3 year mortality. Conclusion LVEF assessed by PRV is a powerful independent predictor of long term mortality after PPCI for STEMI.

  20. Missing left main ostio-proximal coronary artery disease during angiography using tiger catheter

    Directory of Open Access Journals (Sweden)

    Biswajit Majumder

    2016-01-01

    Full Text Available Coronary angiography by right radial artery route using Optitorque Tiger catheter is on the rise given the low rate of local complications and feasibility to perform it as a day-care procedure. We report here a case of coronary angiography performed using Optitorque Tiger catheter (5-French which resulted in a diagnostic error, missing the ostio-proximal left main coronary artery disease which was later detected using EBU 3.5 guide catheter (7-French while performing angioplasty.

  1. Coronary Arteries Segmentation Based on the 3D Discrete Wavelet Transform and 3D Neutrosophic Transform

    OpenAIRE

    Shuo-Tsung Chen; Tzung-Dau Wang; Wen-Jeng Lee; Tsai-Wei Huang; Pei-Kai Hung; Cheng-Yu Wei; Chung-Ming Chen; Woon-Man Kung

    2015-01-01

    Purpose. Most applications in the field of medical image processing require precise estimation. To improve the accuracy of segmentation, this study aimed to propose a novel segmentation method for coronary arteries to allow for the automatic and accurate detection of coronary pathologies. Methods. The proposed segmentation method included 2 parts. First, 3D region growing was applied to give the initial segmentation of coronary arteries. Next, the location of vessel information, HHH subband c...

  2. [Pregnancy and coronary artery dissection].

    Science.gov (United States)

    Martínez-Quintana, Efrén; Rodríguez-González, Fayna

    2015-01-01

    Acute myocardial infarction during pregnancy is associated with high maternal and fetal mortality. Coronary atherosclerosis is the most common cause due to an increase in the age of the patients and the association with cardiovascular risk factors such as smoking, hypertension, diabetes mellitus, preeclampsia, and the existence of family history of coronary disease. However, thrombosis, coronary dissection or coronary vasospasms are other causes that may justify it. We report the case of a 33 weeks pregnant first-time mother, without cardiovascular risk factors, who presented an acute coronary event in the context of atherosclerotic disease and coronary dissection after percutaneous coronary intervention. Copyright © 2014 Sociedad Española de Arteriosclerosis. Published by Elsevier España. All rights reserved.

  3. Diagnosis and prognosis of elderly patients with coronary artery disease. Assessment with dipyridamole thallium imaging

    International Nuclear Information System (INIS)

    Yamasaki, Fumiyasu; Takata, Jun; Seo, Hiromi; Chikamori, Taishiro; Yamada, Mitsutoshi; Yabe, Toshikazu; Doi, Yoshinori

    1995-01-01

    The diagnostic and prognostic value of dipyridamole perfusion scintigraphy was assessed in 147 patients with coronary artery disease aged 65 years and older. All patients underwent coronary angiography. Dipyridamole perfusion scintigraphy was performed safely in all patients. Multiple regression analysis showed that fixed defect and reversible defect were powerful detectors of coronary lesions, all patients with fixed disease and 94% of patients with only reversible defects had significant coronary lesion. Diffuse slow washout and ST depression were statistically significant for detection multivessel coronary lesions in patients with fixed disease, the sensitivity and specificity of diffuse slow washout and/or ST depression for detecting multivessel coronary lesions were 85% and 74%, respectively. Cox survival analysis identified diffuse slow washout as the best predictor of future cardiac events among the scintigraphic variables. Univariate analysis showed the best predictors were age (≥70), diffuse slow washout, and severe coronary lesions. Multivariate analysis showed diffuse slow washout and severe coronary lesions were the best predictors. Dividing the patients by age (≥70) showed that age and diffuse slow washout were good predictors. Scintigraphic and angiographic parameters found diffuse slow washout was the only good predictor. Dipyridamole perfusion scintigraphy is useful for the noninvasive detection of significant coronary artery disease in the elderly, and for predicting future cardiac events with similar predictability to angiographic findings. (S.Y.)

  4. Transesophageal echocardiography in the assessment of coronary arteries; Echokardiografia przezprzelykowa w ocenie proksymalnych odcinkow naczyn wiencowych

    Energy Technology Data Exchange (ETDEWEB)

    Adamek-Kosmider, A.; Kasprzak, J.; Kosmider, M.; Krzeminska-Pakula, M. [Akademia Medyczna, Lodz (Poland)

    1993-12-31

    The study was undertaken to assess the usefulness of TEE for evaluation of morphology and flow in coronary arteries. TEE (2D, spectral and color Doppler imaging) and coronary angiography were performed in 75 patients - 41 with valvular heart disease and 34 with ischemic heart disease. Proximal coronary artery stenosis was detected by coronarography in 11 pts (9-left main coronary artery, 2-right coronary artery). TEE visualization of proximal coronary arteries was possible in all pts. Echocardiographic features of artery stenosis were: the narrowing of the vessel in 2D image (9 pts), high flow velocity spectral Doppler (4 pts, mean 135 cm/s vs 55 cm/s in normal arteries) and mosaic, turbulent flow in color Doppler (10 pts). Sensitivity and specificity of TEE for coronary artery stenosis detection was respectively 81%/98% for 2D imaging and 90%/100% for color Doppler. TEE is a new, noninvasive and safe method for the evaluation of proximal coronary arteries. Detection of LMCA stenosis prior to atheterization may enhance the safety of coronary angiography. (author) 21 refs, 8 figs

  5. Facilitating coronary artery evaluation in MDCT using a 3D automatic vessel segmentation tool

    International Nuclear Information System (INIS)

    Fawad Khan, M.; Gurung, Jessen; Maataoui, Adel; Brehmer, Boris; Herzog, Christopher; Vogl, Thomas J.; Wesarg, Stefan; Dogan, Selami; Ackermann, Hanns; Assmus, Birgit

    2006-01-01

    The purpose of this study was to investigate a 3D coronary artery segmentation algorithm using 16-row MDCT data sets. Fifty patients underwent cardiac CT (Sensation 16, Siemens) and coronary angiography. Automatic and manual detection of coronary artery stenosis was performed. A 3D coronary artery segmentation algorithm (Fraunhofer Institute for Computer Graphics, Darmstadt) was used for automatic evaluation. All significant stenoses (>50%) in vessels >1.5 mm in diameter were protocoled. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of coronary angiography. Sensitivity and specificity were determined for automatic and manual detection as well as was the time for both CT-based evaluation methods. The overall sensitivity and specificity of the automatic and manual approach were 93.1 vs. 95.83% and 86.1 vs. 81.9%. The time required for automatic evaluation was significantly shorter than with the manual approach, i.e., 246.04±43.17 s for the automatic approach and 526.88±45.71 s for the manual approach (P<0.0001). In 94% of the coronary artery branches, automatic detection required less time than the manual approach. Automatic coronary vessel evaluation is feasible. It reduces the time required for cardiac CT evaluation with similar sensitivity and specificity as well as facilitates the evaluation of MDCT coronary angiography in a standardized fashion. (orig.)

  6. Visualization of coronary arteries in patients after childhood Kawasaki syndrome: value of multidetector CT and MR imaging in comparison to conventional coronary catheterization

    International Nuclear Information System (INIS)

    Arnold, Raoul; Ley, Sebastian; Ley-Zaporozhan, Julia; Kauczor, Hans-Ulrich; Eichhorn, Joachim; Ulmer, Herbert; Schenk, Jens-Peter

    2007-01-01

    After childhood Kawasaki syndrome (KS) the coronary arteries undergo a lifelong dynamic pathological change, and follow-up coronary artery imaging is essential. At present, conventional coronary catheterization (CCC) and angiography is still regarded as the gold standard. Less-invasive methods such as multidetector CT angiography (MDCT-A) and MRI have been used sporadically. To compare the diagnostic quality of MDCT-A and MRI with that of CCC for coronary imaging in a group of patients with coronary artery pathology after childhood KS. A total of 16 patients (aged 5-27 years) underwent CCC and 16-row MDCT-A and 14 patients MRI (1.5 T). There was 100% agreement between MDCT-A and CCC in the detection of coronary aneurysms and stenoses. MDCT-A was superior for the visualization of calcified lesions. MRI and CCC showed 93% agreement for the detection of aneurysms. Visualization of coronary artery stenoses was difficult using MRI - one stenosis was missed. MDCT-A has excellent correlation with CCC regarding all changes affecting the coronary arteries in the follow-up of childhood KS. In comparison to MDCT-A and CCC, MRI is less precise in the detection of stenotic lesions. Due to its high image quality and ease of performance MDCT-A should be the primary diagnostic modality in patients following childhood KS. (orig.)

  7. Importance of a Patient Dosimetry and Clinical Follow-up Program in the Detection of Radiodermatitis After Long Percutaneous Coronary Interventions

    Energy Technology Data Exchange (ETDEWEB)

    Vano, Eliseo, E-mail: eliseov@med.ucm.es [Instituto de Investigacion Sanitaria Hospital Clinico San Carlos and Complutense University, Medical Physics Service and Radiology Department (Spain); Escaned, Javier [Hospital Clinico San Carlos, Cardiovascular Institute (Spain); Vano-Galvan, Sergio [Hospital Ramon y Cajal, Dermatology Service (Spain); Fernandez, Jose M. [Instituto de Investigacion Sanitaria Hospital Clinico San Carlos and Complutense University, Medical Physics Service and Radiology Department (Spain); Galvan, Carmen, E-mail: cgalvan@med.ucm.es [Instituto de Investigacion Sanitaria Hospital Clinico San Carlos and Complutense University, Radiotherapy Service and Radiology Department (Spain)

    2013-04-15

    Complex percutaneous interventions often require high radiation doses likely to produce skin radiation injuries. We assessed the methodology used to select patients with potential skin injuries in cardiac procedures and in need of clinical follow-up. We evaluated peak skin dose and clinical follow-up in a case of radiodermatitis produced during a total occlusion recanalization. This prospective study followed CIRSE and ACC/AHA/SCAI recommendations for patient radiation dose management in interventional procedures carried out in a university hospital with a workload of 4200 interventional cardiac procedures per year. Patient dose reports were automatically transferred to a central database. Patients exceeding trigger levels for air kerma area product (500 Gy cm{sup 2}) and cumulative skin dose (5 Gy) were counseled and underwent follow-up for early detection of skin injuries, with dermatologic support. The Ethical Committee and the Quality Assurance and Radiation Safety Committee approved the program. During 2010, a total of 13 patients (3.0/1,000 that year) received dose values exceeding trigger levels in the cardiovascular institute. Only one patient, who had undergone two consecutive procedures resulting in 970 Gy cm{sup 2} and 13.0 Gy as cumulative skin dose, showed signs of serious radiodermatitis that resolved in 3.7 months. The remaining patients did not manifest skin lesions during follow-up, and whenever patient examination was not feasible as part of the follow-up, neither patients nor families reported any skin injuries. Peak skin dose calculation and close clinical follow-up were feasible and appropriate, with a moderate additional workload for the staff and satisfaction for the patient.

  8. Importance of a Patient Dosimetry and Clinical Follow-up Program in the Detection of Radiodermatitis After Long Percutaneous Coronary Interventions

    International Nuclear Information System (INIS)

    Vano, Eliseo; Escaned, Javier; Vano-Galvan, Sergio; Fernandez, Jose M.; Galvan, Carmen

    2013-01-01

    Complex percutaneous interventions often require high radiation doses likely to produce skin radiation injuries. We assessed the methodology used to select patients with potential skin injuries in cardiac procedures and in need of clinical follow-up. We evaluated peak skin dose and clinical follow-up in a case of radiodermatitis produced during a total occlusion recanalization. This prospective study followed CIRSE and ACC/AHA/SCAI recommendations for patient radiation dose management in interventional procedures carried out in a university hospital with a workload of 4200 interventional cardiac procedures per year. Patient dose reports were automatically transferred to a central database. Patients exceeding trigger levels for air kerma area product (500 Gy cm 2 ) and cumulative skin dose (5 Gy) were counseled and underwent follow-up for early detection of skin injuries, with dermatologic support. The Ethical Committee and the Quality Assurance and Radiation Safety Committee approved the program. During 2010, a total of 13 patients (3.0/1,000 that year) received dose values exceeding trigger levels in the cardiovascular institute. Only one patient, who had undergone two consecutive procedures resulting in 970 Gy cm 2 and 13.0 Gy as cumulative skin dose, showed signs of serious radiodermatitis that resolved in 3.7 months. The remaining patients did not manifest skin lesions during follow-up, and whenever patient examination was not feasible as part of the follow-up, neither patients nor families reported any skin injuries. Peak skin dose calculation and close clinical follow-up were feasible and appropriate, with a moderate additional workload for the staff and satisfaction for the patient.

  9. CT coronary angiography vs. invasive coronary angiography in CHD

    Directory of Open Access Journals (Sweden)

    Anja Hagen

    2012-04-01

    Full Text Available Scientific background: Various diagnostic tests including conventional invasive coronary angiography and non-invasive computed tomography (CT coronary angiography are used in the diagnosis of coronary heart disease (CHD. Research questions: The present report aims to evaluate the clinical efficacy, diagnostic accuracy, prognostic value cost-effectiveness as well as the ethical, social and legal implications of CT coronary angiography versus invasive coronary angiography in the diagnosis of CHD. Methods: A systematic literature search was conducted in electronic data bases (MEDLINE, EMBASE etc. in October 2010 and was completed with a manual search. The literature search was restricted to articles published from 2006 in German or English. Two independent reviewers were involved in the selection of the relevant publications. The medical evaluation was based on systematic reviews of diagnostic studies with invasive coronary angiography as the reference standard and on diagnostic studies with intracoronary pressure measurement as the reference standard. Study results were combined in a meta-analysis with 95 % confidence intervals (CI. Additionally, data on radiation doses from current non-systematic reviews were taken into account. A health economic evaluation was performed by modelling from the social perspective with clinical assumptions derived from the meta-analysis and economic assumptions derived from contemporary German sources. Data on special indications (bypass or in-stent-restenosis were not included in the evaluation. Only data obtained using CT scanners with at least 64 slices were considered. Results: No studies were found regarding the clinical efficacy or prognostic value of CT coronary angiography versus conventional invasive coronary angiography in the diagnosis of CHD. Overall, 15 systematic reviews with data from 44 diagnostic studies using invasive coronary angiography as the reference standard (identification of obstructive

  10. Coexistent coronary artery disease or myocardial bridging in patients with hypertrophic cardiomyopathy using coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Hwan; Chun, Eun Ju; Kim, Yeo Koon; Yoo, Jin Young; Choi, Sang Il; Choi, Dong Ju [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2015-07-15

    To evaluate the prevalence of coexistent coronary artery disease (CAD) or myocardial bridging (MB) in patients with hypertrophic cardiomyopathy (HCM) using coronary CT angiography (CCTA) and assess the role of CCTA. The prevalence of obstructive CAD (> 50% luminal reduction) and MB (partial and full encasement) were assessed in 150 patients with HCM diagnosed by clinical findings, electrocardiography, and echocardiography of 19588 consecutive patients who underwent CCTA for suspected CAD. The overall feasibility of coronary artery visualization was 98.9% with CCTA. In patients with HCM, the prevalence of obstructive CAD and MB (14.7% partial and 28.0% full encasement) were 23.3% and 42.7%, respectively. Age, hypertension, family history of premature CAD, Framingham risk score and severe chest pain were associated with CAD, whereas male gender and septal type were associated with MB (all p < 0.05). In comparison to invasive coronary angiography (n = 37), the diagnostic accuracy of CCTA for the detection of CAD and full encasement MB was 89.2% and 86.5%, respectively. One-quarter of patients with HCM had coexistent obstructive CAD or full encasement MB. CCTA can be a feasible and accurate noninvasive imaging modality for the detection of CAD and MB in patients with HCM.

  11. Computerized analysis of coronary artery disease: Performance evaluation of segmentation and tracking of coronary arteries in CT angiograms

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Chuan, E-mail: chuan@umich.edu; Chan, Heang-Ping; Chughtai, Aamer; Kuriakose, Jean; Agarwal, Prachi; Kazerooni, Ella A.; Hadjiiski, Lubomir M.; Patel, Smita; Wei, Jun [Department of Radiology, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2014-08-15

    Purpose: The authors are developing a computer-aided detection system to assist radiologists in analysis of coronary artery disease in coronary CT angiograms (cCTA). This study evaluated the accuracy of the authors’ coronary artery segmentation and tracking method which are the essential steps to define the search space for the detection of atherosclerotic plaques. Methods: The heart region in cCTA is segmented and the vascular structures are enhanced using the authors’ multiscale coronary artery response (MSCAR) method that performed 3D multiscale filtering and analysis of the eigenvalues of Hessian matrices. Starting from seed points at the origins of the left and right coronary arteries, a 3D rolling balloon region growing (RBG) method that adapts to the local vessel size segmented and tracked each of the coronary arteries and identifies the branches along the tracked vessels. The branches are queued and subsequently tracked until the queue is exhausted. With Institutional Review Board approval, 62 cCTA were collected retrospectively from the authors’ patient files. Three experienced cardiothoracic radiologists manually tracked and marked center points of the coronary arteries as reference standard following the 17-segment model that includes clinically significant coronary arteries. Two radiologists visually examined the computer-segmented vessels and marked the mistakenly tracked veins and noisy structures as false positives (FPs). For the 62 cases, the radiologists marked a total of 10191 center points on 865 visible coronary artery segments. Results: The computer-segmented vessels overlapped with 83.6% (8520/10191) of the center points. Relative to the 865 radiologist-marked segments, the sensitivity reached 91.9% (795/865) if a true positive is defined as a computer-segmented vessel that overlapped with at least 10% of the reference center points marked on the segment. When the overlap threshold is increased to 50% and 100%, the sensitivities were 86

  12. Coronary artery bypass grafts: assessment of graft patency and native coronary artery lesions using 16-slice MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Stauder, Norbert I.; Drosch, Tanja; Claussen, Claus D.; Kopp, Andreas F. [Eberhard-Karls-University, Department of Diagnostic Radiology, Tuebingen (Germany); Kuettner, Axel [Friedrich-Alexander-University, Department of Diagnostic Radiology, Erlangen (Germany); Schroeder, Stephen; Beck, Torsten [Eberhard-Karls-University, Department of Internal Medicine, Division Cardiology, Tuebingen (Germany); Stauder, Heidrun [Eberhard-Karls-University, Department of Thoracic and Cardiovascular Surgery, Tuebingen (Germany); Blumenstock, Gunnar [Eberhard-Karls-University, Department of Medical Information Processing, Tuebingen (Germany)

    2006-11-15

    The objective of this study was to evaluate the accuracy of electrocardiography (ECG)-gated 16-slice multidetector-row computed tomography (MDCT) in detection of stenosis of bypass grafts and native coronary arteries in patients who have undergone coronary artery bypass grafting (CABG). ECG-gated contrast-enhanced MDCT using 12 x 0.75-mm collimation was performed in 20 patients with recurrent angina 4.75 years after undergoing CABG. A total of 50 grafts, 16 arterial and 34 venous, were examined. All graft and coronary segments were evaluated for stenosis in comparison with conventional coronary angiography (CCA). Among the 80 arterial graft segments, 62 could be assessed (77.5%). Sensitivity, specificity, and positive and negative predictive values for stenosis were 96.2%, 97.2%, 96.2%, and 97.2%, respectively. In a total of 180 venous graft segments, 167 could be assessed. Sensitivity, specificity, and positive and negative predictive values for stenosis were 98.5%, 93.9%, 91.8%, and 98.9%, respectively. MDCT could assess 179 of 260 native coronary artery segments (68.8%).Sensitivity, specificity, and positive and negative predictive values for stenosis were 92.1%, 76.9%, 87.5%, and 84.7%, respectively. Sixteen-slice MDCT provides excellent image quality and diagnostic accuracy in detection of graft and coronary artery lesions in patients with suspected graft dysfunction. (orig.)

  13. Coronary CT Angiography in the Quantitative Assessment of Coronary Plaques

    Directory of Open Access Journals (Sweden)

    Zhonghua Sun

    2014-01-01

    Full Text Available Coronary computed tomography angiography (CCTA has been recently evaluated for its ability to assess coronary plaque characteristics, including plaque composition. Identification of the relationship between plaque composition by CCTA and patient clinical presentations may provide insight into the pathophysiology of coronary artery plaque, thus assisting identification of vulnerable plaques which are associated with the development of acute coronary syndrome. CCTA-generated 3D visualizations allow evaluation of both coronary lesions and lumen changes, which are considered to enhance the diagnostic performance of CCTA. The purpose of this review is to discuss the recent developments that have occurred in the field of CCTA with regard to its diagnostic accuracy in the quantitative assessment of coronary plaques, with a focus on the characterization of plaque components and identification of vulnerable plaques.

  14. Coronary artery visibility in free-breathing young children on non-gated chest CT: impact of temporal resolution

    Energy Technology Data Exchange (ETDEWEB)

    Bridoux, Alexandre; Hutt, Antoine; Faivre, Jean-Baptiste; Pagniez, Julien; Remy, Jacques; Remy-Jardin, Martine [CHRU et Universite de Lille, Department of Thoracic Imaging, Hospital Calmette (EA 2694), 59037 Lille Cedex (France); Flohr, Thomas [Siemens Healthcare, Department of Research and Development in CT, Forchheim (Germany); Duhamel, Alain [Universite de Lille, Department of Biostatistics, Lille (France)

    2015-11-15

    Dual-source CT allows scanning of the chest with high pitch and high temporal resolution, which can improve the detection of proximal coronary arteries in infants and young children when scanned without general anesthesia, sedation or beta-blockade. To compare coronary artery visibility between higher and standard temporal resolution. We analyzed CT images in 93 children who underwent a standard chest CT angiographic examination with reconstruction of images with a temporal resolution of 75 ms (group 1) and 140 ms (group 2). The percentage of detected coronary segments was higher in group 1 than in group 2 when considering all segments (group 1: 27%; group 2: 24%; P = 0.0004) and proximal segments (group 1: 37%; group 2: 32%; P = 0.0006). In both groups, the highest rates of detection were observed for the left main coronary artery (S1) (group 1: 65%; group 2: 58%) and proximal left anterior descending coronary artery (S2) (group 1: 43%; group 2: 42%). Higher rates of detection were seen in group 1 for the left main coronary artery (P = 0.03), proximal right coronary artery (P = 0.01), proximal segments of the left coronary artery (P = 0.02) and proximal segments of the left and right coronary arteries (P = 0.0006). Higher temporal resolution improved the visibility of proximal coronary arteries in pediatric chest CT. (orig.)

  15. Influence of acquired obesity on coronary vessel wall late gadolinium enhancement in discordant monozygote twins

    Energy Technology Data Exchange (ETDEWEB)

    Makowski, Marcus R. [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Wellcome Trust and EPSRC Medical Engineering Centre, London (United Kingdom); King' s College London, BHF Centre of Excellence, London (United Kingdom); King' s College London, NIHR Biomedical Research Centre, London (United Kingdom); Charite-Universitaetsmedizin, Department of Radiology, Berlin (Germany); Jansen, Christian H.P. [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Ebersberger, Ullrich; Spector, Tim D. [Heart Center Munich-Bogenhausen, Department of Cardiology and Intensive Care Medicine, Munich (Germany); Schaeffter, Tobias; Razavi, Reza [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Wellcome Trust and EPSRC Medical Engineering Centre, London (United Kingdom); King' s College London, BHF Centre of Excellence, London (United Kingdom); King' s College London, NIHR Biomedical Research Centre, London (United Kingdom); Mangino, Massimo [King' s College London, Department of Twin Research and Genetic Epidemiology, London (United Kingdom); National Institute for Health Research (NIHR) Biomedical Research Centre at Guy' s and St. Thomas' Foundation Trust, London (United Kingdom); Botnar, Rene M. [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Wellcome Trust and EPSRC Medical Engineering Centre, London (United Kingdom); King' s College London, BHF Centre of Excellence, London (United Kingdom); King' s College London, NIHR Biomedical Research Centre, London (United Kingdom); Greil, Gerald F. [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Wellcome Trust and EPSRC Medical Engineering Centre, London (United Kingdom); King' s College London, BHF Centre of Excellence, London (United Kingdom); King' s College London, NIHR Biomedical Research Centre, London (United Kingdom)

    2017-11-15

    The aim of this study was to investigate the impact of BMI on late gadolinium enhancement (LGE) of the coronary artery wall in identical monozygous twins discordant for BMI. Coronary LGE represents a useful parameter for the detection and quantification of atherosclerotic coronary vessel wall disease. Thirteen monozygote female twin pairs (n = 26) with significantly different BMIs (>1.6 kg/m2) were recruited out of >10,000 twin pairs (TwinsUK Registry). A coronary 3D-T2prep-TFE MR angiogram and 3D-IR-TFE vessel wall scan were performed prior to and following the administration of 0.2 mmol/kg of Gd-DTPA on a 1.5 T MR scanner. The number of enhancing coronary segments and contrast to noise ratios (CNRs) of the coronary wall were quantified. An increase in BMI was associated with an increased number of enhancing coronary segments (5.3 ± 1.5 vs. 3.5 ± 1.6, p < 0.0001) and increased coronary wall enhancement (6.1 ± 1.1 vs. 4.8 ± 0.9, p = 0.0027) compared to matched twins with lower BMI. This study in monozygous twins indicates that acquired factors predisposing to obesity, including lifestyle and environmental factors, result in increased LGE of the coronary arteries, potentially reflecting an increase in coronary atherosclerosis in this female study population. (orig.)

  16. Influence of acquired obesity on coronary vessel wall late gadolinium enhancement in discordant monozygote twins

    International Nuclear Information System (INIS)

    Makowski, Marcus R.; Jansen, Christian H.P.; Ebersberger, Ullrich; Spector, Tim D.; Schaeffter, Tobias; Razavi, Reza; Mangino, Massimo; Botnar, Rene M.; Greil, Gerald F.

    2017-01-01

    The aim of this study was to investigate the impact of BMI on late gadolinium enhancement (LGE) of the coronary artery wall in identical monozygous twins discordant for BMI. Coronary LGE represents a useful parameter for the detection and quantification of atherosclerotic coronary vessel wall disease. Thirteen monozygote female twin pairs (n = 26) with significantly different BMIs (>1.6 kg/m2) were recruited out of >10,000 twin pairs (TwinsUK Registry). A coronary 3D-T2prep-TFE MR angiogram and 3D-IR-TFE vessel wall scan were performed prior to and following the administration of 0.2 mmol/kg of Gd-DTPA on a 1.5 T MR scanner. The number of enhancing coronary segments and contrast to noise ratios (CNRs) of the coronary wall were quantified. An increase in BMI was associated with an increased number of enhancing coronary segments (5.3 ± 1.5 vs. 3.5 ± 1.6, p < 0.0001) and increased coronary wall enhancement (6.1 ± 1.1 vs. 4.8 ± 0.9, p = 0.0027) compared to matched twins with lower BMI. This study in monozygous twins indicates that acquired factors predisposing to obesity, including lifestyle and environmental factors, result in increased LGE of the coronary arteries, potentially reflecting an increase in coronary atherosclerosis in this female study population. (orig.)

  17. Myocardial imaging by direct injection of thallium-201 into coronary artery

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Inagaki, Suetsugu; Kubota, Yasushi

    1988-01-01

    Myocardial perfusion images were evaluated by direct injection of Thallium (Tl)-201 into coronary artery. Approximately 0.5 - 1 mCi of Tl-201 were instilled into the right coronary artery and/or the left coronary artery after coronary arteriography. Three images were obtained in the anterior, left anterior oblique and left lateral projections. Myocardial perfusion images of single photon emission computed tomography were also acquired in some patients. An image of supreme quality could be obtained in spite of small dose of Tl-201 since there was a lack of interference from background activity. Myocardial perfusion images corresponded to areas which were supplied by left or right coronary artery respectively. And the regional myocardial blood flow distribution of a coronary artery bypass graft could be revealed by instilling Tl-201 into the graft. Further, contribution of collateral channels to myocardial perfusion was showed. Not only left ventricle but also right ventricle was clearly visualized by injection of Tl-201 into right coronary artery. But in a case with arrhythmogenic right ventricular dysplasia, there was an area of decreased tracer uptake in the apex of the right ventricle which was identified as the site of dysplasia by electrophysiologic study. We conclude that direct injection of Tl-201 into coronary artery is an useful method to clarify the correlation between coronary anatomical findings and coronary perfusion and contribution of collaterals to myocardial perfusion, and also to detect the right ventricular myopathic site. (author)

  18. New noninvasive diagnosis of myocardial ischemia of the left circumflex coronary artery using coronary flow reserve measurement by transthoracic Doppler echocardiography. Comparison with thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujimoto, Kohei; Watanabe, Hiroyuki; Hozumi, Takeshi; Otsuka, Ryo; Hirata, Kumiko; Yamagishi, Hiroyuki; Yoshiyama, Minoru; Yoshikawa, Junichi

    2004-01-01

    The usefulness of coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography to detect myocardial ischemia was compared with exercise thallium-201 single photon emission computed tomography (SPECT). Transthoracic Doppler echocardiography was performed in 110 patients with suspected coronary artery disease. Color Doppler signals of the left circumflex coronary artery flow in the apical four-chamber view were identified, and the velocities at rest and during hyperemia recorded for calculation of coronary flow reserve by the pulsed Doppler method. All patients underwent SPECT within 1 week of the transthoracic Doppler echocardiographic study. Coronary flow reserve in the left circumflex coronary artery was measured in 79 (72%) of 110 patients. SPECT revealed reversible perfusion defect in the left circumflex coronary artery territories in 12 of 69 patients excluding those with multivessel disease. Coronary flow reserve <2.0 had a sensitivity of 92% and specificity of 96% for reversible perfusion defect detected by SPECT. Noninvasive coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography can estimate myocardial ischemia in the left ventricular lateral regions. (author)

  19. Intravenous coronary angiography by electron beam computed tomography : a clinical evaluation

    NARCIS (Netherlands)

    Rensing, B J; Bongaerts, A; van Geuns, R J; van Ooijen, P; Oudkerk, M; de Feyter, P J

    1998-01-01

    BACKGROUND: -Noninvasive detection of coronary stenoses with electron beam CT (EBCT) after intravenous injection of contrast medium has recently emerged. We sought to determine the diagnostic accuracy of EBCT angiography in the clinical setting using conventional coronary angiography as the "gold

  20. MR coronary angiography with breath-hold targeted volumes : Preliminary clinical results

    NARCIS (Netherlands)

    van Geuns, R J; Wielopolski, P A; de Bruin, Hein G.; Rensing, B J; Hulshoff, Marc; van Ooijen, P M; de Feyter, P J; Oudkerk, M

    2000-01-01

    PURPOSE: To assess the clinical value of a magnetic resonance (MR) coronary angiography strategy involving a small targeted volume to image one coronary segment in a single breath hold for the detection of greater than 50% stenosis. MATERIALS AND METHODS: Thirty-eight patients referred for elective

  1. MR coronary angiography with breath-hold targeted volumes: preliminary clinical results

    NARCIS (Netherlands)

    R.J.M. van Geuns (Robert Jan); P.A. Wielopolski (Piotr); H.G. de Bruin (Hein); B.J.W.M. Rensing (Benno); M. Hulshoff (Maarten); P.M.A. van Ooijen (Peter); P.J. de Feyter (Pim); M. Oudkerk (Matthijs)

    2000-01-01

    textabstractPURPOSE: To assess the clinical value of a magnetic resonance (MR) coronary angiography strategy involving a small targeted volume to image one coronary segment in a single breath hold for the detection of greater than 50% stenosis. MATERIALS AND METHODS:

  2. Acute heart failure with and without acute coronary syndrome: clinical correlates and prognostic impact (From the HEARTS registry).

    Science.gov (United States)

    AlFaleh, Hussam; Elasfar, Abdelfatah A; Ullah, Anhar; AlHabib, Khalid F; Hersi, Ahmad; Mimish, Layth; Almasood, Ali; Al Ghamdi, Saleh; Ghabashi, Abdullah; Malik, Asif; Hussein, Gamal A; Al-Murayeh, Mushabab; Abuosa, Ahmed; Al Habeeb, Waleed; Kashour, Tarek S

    2016-05-20

    Little is know about the outcomes of acute heart failure (AHF) with acute coronary syndrome (ACS-AHF), compared to those without ACS (NACS-AHF). We conducted a prospective registry of AHF patients involving 18 hospitals in Saudi Arabia between October 2009 and December 2010. In this sub-study, we compared the clinical correlates, management and hospital course, as well as short, and long-term outcomes between AHF patients with and without ACS. Of the 2609 AHF patients enrolled, 27.8 % presented with ACS. Compared to NACS-AHF patients, ACS-AHF patients were more likely to be old males (Mean age = 62.7 vs. 60.8 years, p = 0.003, and 73.8 % vs. 62.7 %, p coronary angiography and had higher prevalence of multi-vessel coronary artery disease (p < 0.001 for all comparisons). The unadjusted hospital and one-month mortality were higher in ACS-AHF patients (OR = 1.6 (1.2-2.2), p = 0.003 and 1.4 (1.0-1.9), p = 0.026 respectively). A significant interaction existed between the level of left ventricular ejection fraction and ACS-AHF status. After adjustment, ACS-AHF status was only significantly associated with hospital mortality (OR = 1.6 (1.1-2.4), p = 0.019). The three-years survival following hospital discharge was not different between the two groups. AHF patients presenting with ACS had worse hospital prognosis, and an equivalent long-term survival compared to AHF patients without ACS. These findings underscore the importance of timely recognition and management of AHF patients with concomitant ACS given their distinct presentation and underlying pathophysiology compared to other AHF patients.

  3. Selective intra-coronary injection of sup(99m)Tc-labelled microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Degeorges, M; Roucayrol, J C; Comet, M; Sol, C; Devaux, J Y; Delebarre, P; d' Izarn, J J [Hopital Cochin, 75 - Paris (France)

    1977-02-01

    A technique of myocardial perfusion imaging and a clinical experience with this technique in 83 patients with coronary artery disease are described. sup(99m)Tc-labelled microspheres were injected directly into one or both major coronary arteries, at the time of coronary arteriography. Microspheres with a mean diameter of 15..mu.. were used. Myocardial infarcts resulting from small vessel occlusions were detected by this technique. The results were compared to those obtained with coronary arteriography and with scintigraphy using /sup 201/Tl or /sup 131/Cs administered intravenously. Certain conclusions regarding coronary arterial injection can be drawn from this comparison. The possibility of irregularities of microsphere distribution after intra-coronary injection must be considered.

  4. Continuous ECG Monitoring in Patients With Acute Coronary Syndrome or Heart Failure: EASI Versus Gold Standard.

    Science.gov (United States)

    Lancia, Loreto; Toccaceli, Andrea; Petrucci, Cristina; Romano, Silvio; Penco, Maria

    2018-05-01

    The purpose of the study was to compare the EASI system with the standard 12-lead surface electrocardiogram (ECG) for the accuracy in detecting the main electrocardiographic parameters (J point, PR, QT, and QRS) commonly monitored in patients with acute coronary syndromes or heart failure. In this observational comparative study, 253 patients who were consecutively admitted to the coronary care unit with acute coronary syndrome or heart failure were evaluated. In all patients, two complete 12-lead ECGs were acquired simultaneously. A total of 6,072 electrocardiographic leads were compared (3,036 standard and 3,036 EASI). No significant differences were found between the investigate parameters of the two measurement methods, either in patients with acute coronary syndrome or in those with heart failure. This study confirmed the accuracy of the EASI system in monitoring the main ECG parameters in patients admitted to the coronary care unit with acute coronary syndrome or heart failure.

  5. Diagnostic Value of Transthoracic Echocardiography in Patients With Anomalous Origin of the Left Coronary Artery From the Pulmonary Artery

    Science.gov (United States)

    Li, Rong-Juan; Sun, Zhonghua; Yang, Jiao; Yang, Ya; Li, Yi-Jia; Leng, Zhao-Ting; Liu, Guo-Wen; Pu, Li-Hong

    2016-01-01

    Abstract Anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA) is a rare congenital coronary abnormality associated with early infant mortality and sudden death in adults. Transthoracic echocardiography (TTE) plays an important role in early detection and diagnosis of ALCAPA as a noninvasive modality. However, its diagnostic value is not well studied. The purpose of this study is to determine the performance of TTE in the diagnostic assessment of ALCAPA as compared with coronary CT and invasive coronary angiography. A total of 22 patients (13 women and 9 men, mean age, 12.9 ± 19.5 years) with ALCAPA who underwent echocardiographic examination for clinical diagnosis were retrospectively reviewed and analyzed. Transthoracic echocardiographic features of ALCAPA were analyzed and its diagnostic value was compared with invasive coronary angiography and coronary CT angiography (CTA) with surgical findings serving as the gold standard. Surgery was performed in all of the patients to establish the dual coronary artery system. Five underwent the Takeuchi procedure and 17 had re-implantation of the anomalous left coronary artery. Of 20 patients, echocardiographic diagnoses were in good agreement with findings at surgery, resulting in the diagnostic accuracy of 90.9%. Two cases were misdiagnosed—one as the right coronary artery to pulmonary artery fistula and the other as rheumatic heart disease. The echocardiographic features of these patients with ALCAPA included: abnormal left coronary ostium arising from the pulmonary trunk with retrograde coronary artery flow in 20 patients; enlargement of the right coronary artery in 17 patients; abundant intercoronary septal collaterals in 17 patients; and moderate and significant mitral regurgitation in 14 patients. The diagnostic accuracy of invasive coronary angiography (in 17 patients) and coronary CTA (in 9 patients) was 100%. This study shows that TTE is an accurate, noninvasive imaging modality

  6. Plain computed tomography for assessment of early coronary microcirculatory damage after revascularization therapy in acute myocardial infarction

    International Nuclear Information System (INIS)

    Kato, Masaya; Dote, Keigo; Sasaki, Shota

    2006-01-01

    Coronary microcirculatory damage is an important factor for the prognosis for acute myocardial infarction (MI) after revascularization. The myocardial enhancement area with contrast media infused during coronary revascularization therapy, detected by computed tomography (CT) just after revascularization, has been reported to correspond to the area of hemorrhagic infarction. The relationship between myocardial contrast enhancement and coronary microcirculatory damage was investigated in the present study. Thirteen patients with acute anterior MI underwent successful coronary revascularization within 6 h of symptom onset were enrolled. The coronary flow velocity pattern was measured using a Doppler guidewire and chest CT assessments were performed immediately after coronary revascularization. The ratio of mean CT number of the highest-enhanced myocardial area and the lumen of the left ventricle was defined as a relative CT number. The relative CT number significantly correlated with coronary diastolic deceleration time (r=-0.78, p<0.002) and coronary diastolic deceleration rate (r=0.74, p<0.04). It also correlated with peak myocardial enzyme release in plasma. Myocardial contrast enhancement detected using plain CT just after coronary reperfusion therapy implies coronary microcirculatory damage in acute MI. The relative CT number is useful in evaluating the impaired coronary microcirculatory state. (author)

  7. Percutaneous transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Przybojewski, J.Z.; Weich, H.F.H.

    1984-01-01

    The purpose of this article is to review PTCA, percutaneous transluminal coronary angioplasty, which can be considered to be a truly revolutionary and fairly simple invasive form of intervention to atherosclerotic obstruction. The 'epidemic' of IHD, ischaemic heart disease, in the Republic of South Africa calls for the employment of this technique, which has already been carried out in a few teaching hospitals in this country. Very recently, modified balloon dilatation catheters have been used percutaneously in the non-operative transluminal correction of congenital coarctation of the aorta in infants and children, congenital pulmonary value stenosis, and hypoplasia and stenosis of the pulmonary arteries. It has also been employed for PTCA and for the simultaneous occlusion of coronary-bronchial artery anastomosis using a detachable balloon. The isotopes thallium 201 and technetium 99 were also used in scintiscanning

  8. Coronary spasm: 201Tl scintiscanning following pharmacological provocation

    International Nuclear Information System (INIS)

    Montz, R.; Mathey, D.; Bleifeld, W.; Hamburg Univ.

    1981-01-01

    According to the authors' experience so far, 201 Tl myocardial scintiscanning is a sufficiently sensitive non-invasive method for detection of coronary vasospasm provoked by ergotamine administration. Mild incomplete and asymptotic forms of coronary vasospasm were detected by scintiscanning. Indications for myocardial scintiscanning of ergotamine-provoked vasospasm are: Cases of angina pectoris at rest in which electrocardiograms during spasm are not available; elleviated symptoms after nitroglycerine administration; exercise electrocardiograms without any sign of ischaemia; negative results of exercise 201 Tl myocardial scintiscanning. (orig.) [de

  9. Meniscotibial (coronary) ligament tears

    International Nuclear Information System (INIS)

    El-Khoury, G.Y.; Usta, H.Y.; Berger, R.A.

    1984-01-01

    Preservation of the meniscus whenever possible is essential in maintaining knee stability and preventing premature osteoarthritis. Peripheral meniscal tears are the most amenable to surgical repair. This study evaluates the peripheral attachments of the medial meniscus and focuses on a specific tear limited to the meniscotibial ligament (coronary ligament). The diagnosis is made arthrographically when the medial meniscus floats above the tibial plateau without separating completely from the capsule. The lateral meniscus is rarely involved in this type of injury. (orig.)

  10. Serum protein profiles predict coronary artery disease in symptomatic patients referred for coronary angiography

    Directory of Open Access Journals (Sweden)

    LaFramboise William A

    2012-12-01

    Full Text Available Abstract Background More than a million diagnostic cardiac catheterizations are performed annually in the US for evaluation of coronary artery anatomy and the presence of atherosclerosis. Nearly half of these patients have no significant coronary lesions or do not require mechanical or surgical revascularization. Consequently, the ability to rule out clinically significant coronary artery disease (CAD using low cost, low risk tests of serum biomarkers in even a small percentage of patients with normal coronary arteries could be highly beneficial. Methods Serum from 359 symptomatic subjects referred for catheterization was interrogated for proteins involved in atherogenesis, atherosclerosis, and plaque vulnerability. Coronary angiography classified 150 patients without flow-limiting CAD who did not require percutaneous intervention (PCI while 209 required coronary revascularization (stents, angioplasty, or coronary artery bypass graft surgery. Continuous variables were compared across the two patient groups for each analyte including calculation of false discovery rate (FDR ≤ 1% and Q value (P value for statistical significance adjusted to ≤ 0.01. Results Significant differences were detected in circulating proteins from patients requiring revascularization including increased apolipoprotein B100 (APO-B100, C-reactive protein (CRP, fibrinogen, vascular cell adhesion molecule 1 (VCAM-1, myeloperoxidase (MPO, resistin, osteopontin, interleukin (IL-1β, IL-6, IL-10 and N-terminal fragment protein precursor brain natriuretic peptide (NT-pBNP and decreased apolipoprotein A1 (APO-A1. Biomarker classification signatures comprising up to 5 analytes were identified using a tunable scoring function trained against 239 samples and validated with 120 additional samples. A total of 14 overlapping signatures classified patients without significant coronary disease (38% to 59% specificity while maintaining 95% sensitivity for patients requiring

  11. Detecting asymptomatic coronary artery disease using routine ...

    African Journals Online (AJOL)

    1990-09-01

    Sep 1, 1990 ... using an adaptable Wiirburg arm ergometer according to the protocol suggested ... axis, horizontal long axis and short axis of the heart were obtained. On these ... reach 85% of their MPHR with a normal stress test. Another 4.

  12. Visualization of atherosclerosis as detected by coronary artery calcium and carotid intima-media thickness reveals significant atherosclerosis in a cross-sectional study of psoriasis patients in a tertiary care center.

    Science.gov (United States)

    Santilli, S; Kast, D R; Grozdev, I; Cao, L; Feig, R L; Golden, J B; Debanne, S M; Gilkeson, R C; Orringer, C E; McCormick, T S; Ward, N L; Cooper, K D; Korman, N J

    2016-07-22

    Psoriasis is a chronic inflammatory disease of the skin and joints that may also have systemic inflammatory effects, including the development of cardiovascular disease (CVD). Multiple epidemiologic studies have demonstrated increased rates of CVD in psoriasis patients, although a causal link has not been established. A growing body of evidence suggests that sub-clinical systemic inflammation may develop in psoriasis patients, even from a young age. We aimed to evaluate the prevalence of atherosclerosis and identify specific clinical risk factors associated with early vascular inflammation. We conducted a cross-sectional study of a tertiary care cohort of psoriasis patients using coronary artery calcium (CAC) score and carotid intima-media thickness (CIMT) to detect atherosclerosis, along with high sensitivity C-reactive protein (hsCRP) to measure inflammation. Psoriasis patients and controls were recruited from our tertiary care dermatology clinic. Presence of atherosclerosis was defined using validated numeric values within CAC and CIMT imaging. Descriptive data comparing groups was analyzed using Welch's t test and Pearson Chi square tests. Logistic regression was used to analyze clinical factors associated with atherosclerosis, and linear regression to evaluate the relationship between psoriasis and hsCRP. 296 patients were enrolled, with 283 (207 psoriatic and 76 controls) having all data for the hsCRP and atherosclerosis analysis. Atherosclerosis was found in 67.6 % of psoriasis subjects versus 52.6 % of controls; Psoriasis patients were found to have a 2.67-fold higher odds of having atherosclerosis compared to controls [95 % CI (1.2, 5.92); p = 0.016], after adjusting for age, gender, race, BMI, smoking, HDL and hsCRP. In addition, a non-significant trend was found between HsCRP and psoriasis severity, as measured by PASI, PGA, or BSA, again after adjusting for confounders. A tertiary care cohort of psoriasis patients have a high prevalence of early

  13. Prevalence of asymptomatic coronary disease in fibrosing idiopathic interstitial pneumonias

    International Nuclear Information System (INIS)

    Cassagnes, Lucie; Gaillard, Vianney; Monge, Emmanuel; Faivre, Jean-Baptiste; Delhaye, Cédric; Molinari, Francesco; Petyt, Grégory; Hossein-Foucher, Claude; Wallaert, Benoit; Duhamel, Alain; Remy, Jacques; Remy-Jardin, Martine

    2015-01-01

    Background: Because of growing body of interest on the association between fibrosing idiopathic interstitial pneumonias (f-IIP) and ischaemic heart disease, we initiated this prospective study to evaluate the prevalence of asymptomatic coronary artery disease (CAD) in patients with f-IIP. Methods: Forty-two patients with f-IIP underwent noninvasive screening for CAD that included (a) a chest CT examination enabling calculation of the coronary artery calcium (CAC) score, then depiction of coronary artery stenosis; and (b) stress myocardial perfusion scintigraphy (MPS). Patients with significant coronary abnormalities, defined by a CAC score >400 or coronary artery stenosis >50% at CT and/or perfusion defect >5% at MPS, were referred to the cardiologist. Coronary angiography was indicated in presence of a perfusion defect >10% at MPS or significant left main or proximal left anterior descending stenosis whatever MPS findings. Results: Combining CT and MPS, significant abnormalities were detected in 32/42 patients (76%). The cardiologist: (a) did not consider further investigation in 21 patients (CT abnormalities but no ischaemia at MPS: 12/21; false-positive findings at MPS: 3/21; poor respiratory condition: 6/21); (b) proceeded to coronary angiography in 11 patients which confirmed significant stenoses in 5 patients (5/42; 12%). In the worst-case-scenario (i.e., inclusion of 6 patients with significant coronary artery abnormalities who were not investigated due to poor respiratory condition), the prevalence of CAD reached 26% (11/42). Conclusion: In the studied population of patients with f-IIP, asymptomatic CAD ranged between 12% and 26%

  14. Fate of coronary ostial anastomoses after the modified Bentall procedure.

    Science.gov (United States)

    Milano, Aldo D; Pratali, Stefano; Mecozzi, Gianclaudio; Boraschi, Piero; Braccini, Giovanni; Magagnini, Enrico; Bortolotti, Uberto

    2003-06-01

    Introduction of the modified Bentall procedure with the button technique has reduced but not eliminated anastomotic complications in patients receiving a composite aortic conduit. Particularly the true incidence of coronary ostial complications such as stenosis, kinking or pseudoaneurysm formation needs to be assessed. We reviewed 71 patients receiving a composite aortic conduit from November 1993 to November 1999 for chronic aneurysms (n = 51) or aortic dissection (n = 20), 12 of whom had Marfan syndrome. Patients were divided into two groups according to variations in the surgical technique. In group 1 (30 patients; 42%) the classic modified Bentall operation with the button technique was employed whereas in group 2 (41 patients; 58%) some technical modifications were added mainly consisting of a reinforcement suture joining the cut edge of the aortic wall and the prosthetic sewing ring and suture of the coronary buttons with an "endo-button" technique. To detect potential procedure-related complications particularly at the coronary ostia anastomoses follow-up included transthoracic two-dimensional echocardiography every 6 months and computerized tomographic angiography at 12 months or whenever indicated; in 20 patients a magnetic resonance imaging angiography and standard aortography with selective coronary angiography were also added. At a mean follow-up of 49 +/- 19 months anastomotic complications occurred in 4 patients (6%): in 2 a pseudoaneurysm developed at the distal aortic suture line and in 1 a pseudoaneurysm developed at the right coronary ostium after repair of acute aortic dissection; in 1 Marfan patient an aneurysm of the left coronary ostium developed. Such complications were unrelated to the two surgical techniques used in this series for reimplantaion of the coronary ostia. The modified Bentall operation is associated with an extremely low incidence of anastomotic complications particularly at the coronary ostia. More extensive use of new imaging

  15. Prevalence of asymptomatic coronary disease in fibrosing idiopathic interstitial pneumonias

    Energy Technology Data Exchange (ETDEWEB)

    Cassagnes, Lucie; Gaillard, Vianney [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Monge, Emmanuel [Department of Pulmonology, Center of Competence for Rare Pulmonary Diseases, Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Faivre, Jean-Baptiste [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Delhaye, Cédric [Department of Cardiology, Cardiology Hospital, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Molinari, Francesco [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Petyt, Grégory; Hossein-Foucher, Claude [Department of Nuclear Medicine, Hospital Salengro, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Wallaert, Benoit [Department of Pulmonology, Center of Competence for Rare Pulmonary Diseases, Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Duhamel, Alain [Department of Medical Statistics (EA 2694), Univ Lille Nord de France, F-59000 Lille (France); Remy, Jacques [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France); Remy-Jardin, Martine, E-mail: martine.remy@chru-lille.fr [Department of Thoracic Imaging (EA 2694), Hospital Calmette, CHRU and Univ Lille 2 Nord de France, F-59000 Lille (France)

    2015-01-15

    Background: Because of growing body of interest on the association between fibrosing idiopathic interstitial pneumonias (f-IIP) and ischaemic heart disease, we initiated this prospective study to evaluate the prevalence of asymptomatic coronary artery disease (CAD) in patients with f-IIP. Methods: Forty-two patients with f-IIP underwent noninvasive screening for CAD that included (a) a chest CT examination enabling calculation of the coronary artery calcium (CAC) score, then depiction of coronary artery stenosis; and (b) stress myocardial perfusion scintigraphy (MPS). Patients with significant coronary abnormalities, defined by a CAC score >400 or coronary artery stenosis >50% at CT and/or perfusion defect >5% at MPS, were referred to the cardiologist. Coronary angiography was indicated in presence of a perfusion defect >10% at MPS or significant left main or proximal left anterior descending stenosis whatever MPS findings. Results: Combining CT and MPS, significant abnormalities were detected in 32/42 patients (76%). The cardiologist: (a) did not consider further investigation in 21 patients (CT abnormalities but no ischaemia at MPS: 12/21; false-positive findings at MPS: 3/21; poor respiratory condition: 6/21); (b) proceeded to coronary angiography in 11 patients which confirmed significant stenoses in 5 patients (5/42; 12%). In the worst-case-scenario (i.e., inclusion of 6 patients with significant coronary artery abnormalities who were not investigated due to poor respiratory condition), the prevalence of CAD reached 26% (11/42). Conclusion: In the studied population of patients with f-IIP, asymptomatic CAD ranged between 12% and 26%.

  16. Stable coronary syndromes: pathophysiology, diagnostic advances and therapeutic need

    Science.gov (United States)

    Corcoran, David

    2018-01-01

    The diagnostic management of patients with angina pectoris typically centres on the detection of obstructive epicardial CAD, which aligns with evidence-based treatment options that include medical therapy and myocardial revascularisation. This clinical paradigm fails to account for the considerable proportion (approximately one-third) of patients with angina in whom obstructive CAD is excluded. This common scenario presents a diagnostic conundrum whereby angina occurs but there is no obstructive CAD (ischaemia and no obstructive coronary artery disease—INOCA). We review new insights into the pathophysiology of angina whereby myocardial ischaemia results from a deficient supply of oxygenated blood to the myocardium, due to various combinations of focal or diffuse epicardial disease (macrovascular), microvascular dysfunction or both. Macrovascular disease may be due to the presence of obstructive CAD secondary to atherosclerosis, or may be dynamic due to a functional disorder (eg, coronary artery spasm, myocardial bridging). Pathophysiology of coronary microvascular disease may involve anatomical abnormalities resulting in increased coronary resistance, or functional abnormalities resulting in abnormal vasomotor tone. We consider novel clinical diagnostic techniques enabling new insights into the causes of angina and appraise the need for improved therapeutic options for patients with INOCA. We conclude that the taxonomy of stable CAD could improve to better reflect the heterogeneous pathophysiology of the coronary circulation. We propose the term ‘stable coronary syndromes’ (SCS), which aligns with the well-established terminology for ‘acute coronary syndromes’. SCS subtends a clinically relevant classification that more fully encompasses the different diseases of the epicardial and microvascular coronary circulation. PMID:29030424

  17. Anomalous origin of coronary artery: the role of multislice CT Angiography: a case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    Rabelo, Daniel Rocha; Barros, Marcio Vinicius Lins; Nunes, Maria do Carmo Pereira; Siqueira, Maria Helena Albernaz, E-mail: marciovlbarros@uol.com.br [Hospital Mater Dei, Belo Horizonte, MG (Brazil)

    2012-07-15

    Anomalous origin of coronary arteries is a relatively rare entity and can present different clinical forms. Recently, CT angiography of the coronary arteries have demonstrated an important role in the diagnosis and management of these anomalies. We present the case of a young female without significant comorbidities who presented with cardiopulmonary arrest, being revived by a team of customer service mobile emergency. After completion of multislice CT angiography of the coronary arteries was observed anomalous origin of left main coronary artery in the right coronary artery, no signs of extrinsic compression. Patient received a defibrillator and had an uneventful follow-up performed. Multislice CT angiography is minimally invasive diagnostic methods to detect the origin and trajectory of the coronary arteries, allowing an alternative to cardiac catheterization for evaluation of patients with anomalous origin of coronary arteries. (author)

  18. Diagnostic Value of Electrocardiographic T Wave Inversion in Lead aVL in Diagnosing Coronary Artery Disease in Patients with Chronic Stable Angina

    Directory of Open Access Journals (Sweden)

    Hatem L. Farhan

    2010-04-01

    Full Text Available Objectives: The clinical value of T wave inversion in lead aVL in diagnosing coronary artery disease (CAD remains unclear. This study aims to investigate the correlation between aVL T wave inversion and CAD in patients with chronic stable angina.Methods: Electrocardiograms (ECGs of 257 consecutive patients undergoing coronary angiography were analyzed. All patients had chronic stable angina. All patients with secondary T wave inversion had been excluded (66 patients. The remaining 191 patients constituted the study population. Detailed ECG interpretation and coronary angiographic findings were conducted by experienced cardiologists.Results: T wave inversion in aVL was identified in 89 ECGs (46.8% with definite ischemic Q-ST-T changes in different leads in 97 ECGs (50.8%. Stand alone aVL T wave inversion was found in 27 ECGs (14.1% while ischemic changes in other leads with normal aVL were identified in 36 ECGs (18.8%. The incidence of CAD was 86.3%. Single, two- and multi-vessel CAD were found in 38.8%, 28.5% and 32.7% of cases respectively. The prevalence of left main, left anterior descending, left circumflex and right coronary arteries were 4.7%, 61.2%, 29.3% and 44.5%, respectively. T wave inversion in aVL was found to be the only ECG variable significantly predicting mid segment left anterior descending artery (LAD lesions (Odds Ratio 2.93, 95% Confidence Interval 1.59-5.37, p=0.001.Conclusion: This study provides new information relating to T wave inversion in lead aVL to mid segment LAD lesions. Implication of this simple finding may help in bedside diagnosis of CAD typically mid LAD lesions. However, further studies are needed to corroborate this finding.

  19. Coffee consumption and coronary calcification - The Rotterdam Coronary Calcification Study

    NARCIS (Netherlands)

    van Woudenbergh, Geertruida J.; Vliegenthart, Rozemarijn; van Rooij, Frank J. A.; Hofman, Albert; Oudkerk, Matthijs; Witteman, Jacqueline C. M.; Geleijnse, Johanna M.

    Background-The role of coffee in the cardiovascular system is not yet clear. We examined the relation of coffee intake with coronary calcification in a population-based cohort. Methods and Results-The study involved 1570 older men and women without coronary heart disease who participated in the

  20. Coffee consumption and coronary calcification: The Rotterdam coronary calcification study

    NARCIS (Netherlands)

    G.J. van Woudenbergh (Geertruida); R. Vliegenthart (Rozemarijn); F.J.A. van Rooij (Frank); A. Hofman (Albert); M. Oudkerk (Matthijs); J.C.M. Witteman (Jacqueline); J.M. Geleijnse (Marianne)

    2008-01-01

    textabstractBACKGROUND - The role of coffee in the cardiovascular system is not yet clear. We examined the relation of coffee intake with coronary calcification in a population-based cohort. METHODS AND RESULTS - The study involved 1570 older men and women without coronary heart disease who

  1. Coffee Consumption and Coronary Calcification: The Rotterdam Coronary Calcification Study

    NARCIS (Netherlands)

    Woudenbergh, van G.J.; Vliegenthart, R.; Rooij, van F.J.A.; Hofman, A.; Oudkerk, M.; Witteman, J.C.M.; Geleijnse, J.M.

    2008-01-01

    Background¿ The role of coffee in the cardiovascular system is not yet clear. We examined the relation of coffee intake with coronary calcification in a population-based cohort. Methods and Results¿ The study involved 1570 older men and women without coronary heart disease who participated in the

  2. Arterial bending angle and wall morphology correlate with slow coronary flow: Determination with multidetector CT coronary angiography

    International Nuclear Information System (INIS)

    Kantarci, Mecit; Guendogdu, Fuat; Doganay, Selim; Duran, Cihan; Kalkan, M. Emin; Sagsoz, M. Erdem; Kucuk, Osman; Karakaya, Afak; Kucuk, Ahmet; Akguen, Metin

    2011-01-01

    Background and purpose: The purpose of this study was to assess angulations and vessel wall morphology that could lead to bending head loss in the RCA and LMCA arteries of patients with slow coronary flow (SCF) evaluated by MDCT coronary angiography. Methods: The study involved 51 patients (45 males, mean age: 59.6 years) who were diagnosed with SCF by coronary angiography. Diagnosis of SCF was based on thrombolysis in myocardial infarction (TIMI) frame count. Fifty-one patients with absence of slow flow were selected as the control group. The angulations of the main coronary arteries with the aorta were measured from the axial images obtained through MDCT coronary angiography, and the findings were recorded. In addition, the coronary artery walls of these patients were evaluated. For statistical analysis, SPSS for Windows 10.0 (SPSS Inc., Chicago, IL) was used. For comparisons of the angles, either independent samples t test or the Mann-Whitney U test was used where appropriate. Results: The results of the study indicated that 38 patients had SCF in the LAD. Comparisons of patients with SCF with the controls revealed that in the patients with SCF, the mean angle of the LMCA with the aorta (40.9 ± 20.5 o ) was statistically significantly smaller than the mean angle of the LMCA with the aorta in the control cases (71.8 ± 11 o ). In 12 patients, slow flow was detected in the RCA. Those with slow flow in the RCA had significantly smaller angles (mean: 33.2 ± 20.4 o ) than the other cases (mean: 78.9 ± 10.7 o ). Conclusion: A small angle of origin of the main coronary arteries from the aorta, measured on MDCT examinations is correlated with slow blood flow in those vessels, as calculated by the TIMI frame count in catheter coronary angiography.

  3. Congenital coronary artery anomalies: diagnosis with 64 slice multidetector row computed tomography coronary angiography: A single Centre Study

    International Nuclear Information System (INIS)

    Srnivasan, K.G.; Gaikward, A.; Kannan, B.R.J.; Ritesh, K.; Ushanandini, K.P.

    2008-01-01

    Full text: Retrospective review of the congenital coronary artery (CA) anomalies detected by a 64-slice multidetector row computed tomographic (MDCT) angiography. The type of the anomaly, imaging characteristics, clinical relevance and the superiority of the MDCT over conventional coronary angiography are discussed. Multidetector row computed tomographic coronary angiography was carried out by the usual technique with 70 cc of non-ionic contrast agent and retrospective electrocardiogram gating. The volume data obtained were reconstructed in axial plane, along with volume-rendered three-dimensional reconstruction and virtual angioscopy in selected patients. The images were analysed by a radiologist, experienced in cardiac CT, and an experienced cardiologist. A retrospective review of the records was carried out, and subjects with congenital coronary anomalies were included in the study. Between 15 November 2005 and 27 February 2007, 1495 MDCT coronary angiograms were carried out. Eleven of them were found to have coronary anomalies. Five had absent left main CA. Two had interarterial course of the left main CA artery passing in between the right ventricular outflow tract and the root of aorta. In one patient, there was aberrant origin of right CA from the left aortic sinus with subsequent interarterial course and another one had aberrant origin of circumflex artery from the right aortic sinus. One patient each of congenitally absent circumflex artery and atresia of the right CA were found. Sixty-four slice MDCT coronary angiography provided accurate depiction of anomalous vessel origin and course along with the complex anatomical relation with the adjacent structures. CTcan be considered as a first-line imaging method for delineating coronary arterial anomalies.

  4. Prospective Coronary Heart Disease Screening in Asymptomatic Hodgkin Lymphoma Patients Using Coronary Computed Tomography Angiography: Results and Risk Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Girinsky, Theodore, E-mail: girinsky.theodore@orange.fr [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); M’Kacher, Radhia [Laboratory of Radiobiology and Oncology, Institut de Radiobiologie Cellulaire et Moleculaire/Direction des Sciences Vivantes/Commissariat Energie Atomique, Fontenay aux Roses (France); Lessard, Nathalie [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Koscielny, Serge [Biostatistics and Epidemiology Unit, Institut Gustave Roussy, Villejuif (France); Elfassy, Eric; Raoux, François [Department of Radiology, Marie Lannelongue, Chatenay-Malabry (France); Carde, Patrice [Department of Hematology, Institut Gustave Roussy, Villejuif (France); Santos, Marcos Dos [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Margainaud, Jean-Pierre [Department of Head and Neck Surgery, Institut Gustave Roussy, Villejuif (France); Sabatier, Laure [Laboratory of Radiobiology and Oncology, Institut de Radiobiologie Cellulaire et Moleculaire/Direction des Sciences Vivantes/Commissariat Energie Atomique, Fontenay aux Roses (France); Ghalibafian, Mithra [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Paul, Jean-François [Department of Radiology, Marie Lannelongue, Chatenay-Malabry (France)

    2014-05-01

    Purpose: To prospectively investigate the coronary artery status using coronary CT angiography (CCTA) in patients with Hodgkin lymphoma treated with combined modalities and mediastinal irradiation. Methods and Materials: All consecutive asymptomatic patients with Hodgkin lymphoma entered the study during follow-up, from August 2007 to May 2012. Coronary CT angiography was performed, and risk factors were recorded along with leukocyte telomere length (LTL) measurements. Results: One hundred seventy-nine patients entered the 5-year study. The median follow-up was 11.6 years (range, 2.1-40.2 years), and the median interval between treatment and the CCTA was 9.5 years (range, 0.5-40 years). Coronary artery abnormalities were demonstrated in 46 patients (26%). Coronary CT angiography abnormalities were detected in nearly 15% of the patients within the first 5 years after treatment. A significant increase (34%) occurred 10 years after treatment (P=.05). Stenoses were mostly nonostial. Severe stenoses were observed in 12 (6.7%) of the patients, entailing surgery with either angioplasty with stent placement or bypass grafting in 10 of them (5.5%). A multivariate analysis demonstrated that age at treatment, hypertension, and hypercholesterolemia, as well as radiation dose to the coronary artery origins, were prognostic factors. In the group of patients with LTL measurements, hypertension and LTL were the only independent risk factors. Conclusions: The findings suggest that CCTA can identify asymptomatic individuals at risk of acute coronary artery disease who might require either preventive or curative measures. Conventional risk factors and the radiation dose to coronary artery origins were independent prognostic factors. The prognostic value of LTL needs further investigation.

  5. Arterial bending angle and wall morphology correlate with slow coronary flow: Determination with multidetector CT coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kantarci, Mecit, E-mail: akkanrad@hotmail.com [Department of Radiology, Medical Faculty, Atatuerk University, Erzurum (Turkey); Guendogdu, Fuat [Department of Cardiology, Medical Faculty, Atatuerk University, Erzurum (Turkey); Doganay, Selim [Department of Radiology, Medical Faculty, Erciyes University, Kayseri (Turkey); Duran, Cihan [Department of Radiology, Bilim University, Florence Nightingale Hospital, Istanbul (Turkey); Kalkan, M. Emin [Department of Cardiology, Medical Faculty, Atatuerk University, Erzurum (Turkey); Sagsoz, M. Erdem [Department of Radiology, Medical Faculty, Atatuerk University, Erzurum (Turkey); Kucuk, Osman [Department of Electronic Engineering, Engineering Faculty, Atatuerk University, Erzurum (Turkey); Karakaya, Afak [Department of Radiology, Medical Faculty, Atatuerk University, Erzurum (Turkey); Kucuk, Ahmet [Department of Mathematics, Science Faculty, Atatuerk University, Erzurum (Turkey); Akguen, Metin [Department of Chest, Medical Faculty, Atatuerk University, Erzurum (Turkey)

    2011-01-15

    Background and purpose: The purpose of this study was to assess angulations and vessel wall morphology that could lead to bending head loss in the RCA and LMCA arteries of patients with slow coronary flow (SCF) evaluated by MDCT coronary angiography. Methods: The study involved 51 patients (45 males, mean age: 59.6 years) who were diagnosed with SCF by coronary angiography. Diagnosis of SCF was based on thrombolysis in myocardial infarction (TIMI) frame count. Fifty-one patients with absence of slow flow were selected as the control group. The angulations of the main coronary arteries with the aorta were measured from the axial images obtained through MDCT coronary angiography, and the findings were recorded. In addition, the coronary artery walls of these patients were evaluated. For statistical analysis, SPSS for Windows 10.0 (SPSS Inc., Chicago, IL) was used. For comparisons of the angles, either independent samples t test or the Mann-Whitney U test was used where appropriate. Results: The results of the study indicated that 38 patients had SCF in the LAD. Comparisons of patients with SCF with the controls revealed that in the patients with SCF, the mean angle of the LMCA with the aorta (40.9 {+-} 20.5{sup o}) was statistically significantly smaller than the mean angle of the LMCA with the aorta in the control cases (71.8 {+-} 11{sup o}). In 12 patients, slow flow was detected in the RCA. Those with slow flow in the RCA had significantly smaller angles (mean: 33.2 {+-} 20.4{sup o}) than the other cases (mean: 78.9 {+-} 10.7{sup o}). Conclusion: A small angle of origin of the main coronary arteries from the aorta, measured on MDCT examinations is correlated with slow blood flow in those vessels, as calculated by the TIMI frame count in catheter coronary angiography.

  6. Estimation of coronary flow reserve by sestamibi imaging in patients with mild hypertension and normal coronary arteries

    International Nuclear Information System (INIS)

    Storto, G.; Gallicchio, R.; Maddalena, F.; Pellegrino, T.; Petretta, M.; Fiumara, G.; Cuocolo, A.

    2015-01-01

    Patients with hypertension may exhibit abnormal vasodilator capacity during pharmacological vasodilatation. We assessed coronary flow reserve (CFR) by sestamibi imaging in hypertensive patients with normal coronary vessels. Twenty-five patients with untreated mild essential hypertension and normal coronary vessels and 10 control subjects underwent dipyridamole-rest Tc-99m sestamibi imaging. Myocardial blood flow (MBF) was estimated by measuring first transit counts in pulmonary artery and myocardial counts from tomograhic images. CFR was expressed as the ratio of stress to rest MBF. Coronary vascular resistances (CVR) were computed as the ratio between mean arterial pressure and MBF. Estimated MBF at rest was not different in patients and controls (1.11±0.59 vs. 1.14±0.28 counts/pixel/s; P=0.87). Conversely, stress MBF was lower in patients than in controls (1.55±0.47 vs. 2.68±0.53 counts/pixel/s; P<0.001). Thus, CFR was reduced in patients compared to controls (1.61±0.58 vs. 2.43±0.62; P<0.001). Rest and stress CVR values were higher in patients (P<0.001), while stress-induced changes in CVR were not different (P=0.08) between patients (-51%) and controls (-62%). In the overall study population, a significant relation between CFR and stress-induced changes in CVR was observed (r=-0.86; P<0.001). Sestamibi imaging may detect impaired coronary vascular function in response to dipyridamole in patients with untreated mild essential hypertension and normal coronary arteries. A mild increase in arterial blood pressure does not affect baseline MBF, but impairs coronary reserve due to the amplified resting coronary resistances.

  7. [Developments in percutaneous coronary intervention and coronary stents].

    Science.gov (United States)

    Simsek, C; Daemen, J; Zijlstra, F

    2014-01-01

    In The Netherlands, more than 30.000 patients undergo a percutaneous coronary intervention every year, during which a coronary stent implantation will be performed in 90% of the cases. It is estimated that more than 5 million coronary stent implantations will be performed worldwide this year. While these numbers are impressive, however, coronary stents still have as a limitation the possibility of stent thrombosis. This has been and is an important stimulus for the development of both coronary stents, from a bare metal stent via a drug eluting stent to the present-day development of bio-absorbable stents, and anti-platelet drugs,from acenocoumarol to thieropyridines. The possibility of shortening the period of use of this powerful medication by developing new kinds of non-thrombogenic stents would, for example, make it possible to achieve significant reductions in subsequent bleeding during (dental) procedures.

  8. Exeqüibilidade, segurança e acurácia do ecocardiograma sob estresse com dobutamina/ atropina para detecção de doença arterial coronariana em candidatos a transplante renal Feasibility, safety and accuracy of dobutamine/atropine stress echocardiography for the detection of coronary artery disease in renal transplant candidates

    Directory of Open Access Journals (Sweden)

    Pedro Antonio Muniz Ferreira

    2007-01-01

    Full Text Available OBJETIVO: Avaliar a exeqüibilidade, a segurança e a acurácia diagnóstica do ecocardiograma sob estresse (EEDA com dobutamina/atropina em candidatos a transplante renal. MÉTODOS: Pacientes candidatos a transplante renal com e sem nefropatia diabética realizaram EEDA e cineangiocoronariografia. Consideraram-se dois pontos de corte para doença arterial coronariana (DAC: > 50% e > 70% de obstrução de uma artéria epicárdica. RESULTADOS: Cento e quarenta e oito pacientes realizaram o EEDA e a angiografia coronariana. A média de idade foi de 52±9 anos, 69% eram do sexo masculino, 27% tinham nefropatia diabética, e 73%, HVE; 63% estavam assintomáticos, 36% e 22% apresentaram obstruções coronarianas > 50% e > 70%, respectivamente. A exeqüibilidade foi de 91% e houve 2,7% de complicações maiores. Obtiveram-se as seguintes médias de sensibilidade, especificidade e acurácia, considerando obstrução coronariana > 50%: 53% (IC:45-61, 87% (IC:81-93, e 75% (IC:63-83, respectivamente. Para obstrução >70%, 71% (IC:64-92, 85% (IC:79-91 e 81% (IC:75-87. A sensibilidade para diagnosticar doença uniarterial foi 41% (IC:19-63 e doença multiarterial, 78% (IC:64-92. CONCLUSÃO: O EEDA foi exeqüível e seguro; entretanto, foi ineficiente para rastreamento de DAC, considerando obstruções > 50%, mas pode ser útil para detecção de DAC em pacientes com obstruções > 70% e doença multiarterial.OBJECTIVE: To evaluate the feasibility, safety and accuracy of dobutamine/atropine stress echocardiography (DASE for the detection of coronary artery desease (CAD in renal transplant candidates. METHODS: Patients candidates to renal transplant were submitted consecutively to DASE and coronary angiography. The adopted angiographic criteria for CAD were an obstructive lesion of > 50% and > 70%. RESULTS: 148 patients underwent the DASE and the coronary angiography. Mean age was 52 ± 9 years, 69% of the patients were males; 27% had diabetic nephropathy

  9. Estrogen-induced improvement in coronary flow responses during atrial pacing in relation to endothelin-1 levels in postmenopausal women without coronary disease

    Directory of Open Access Journals (Sweden)

    Ioannis Kallikazaros

    2008-06-01

    Full Text Available Ioannis Kallikazaros, Costas Tsioufis, Panagiotis Zambaras, Ioannis Skiadas, Marina Toutouza, Dimitrios Tousoulis, Christodoulos Stefanadis, Pavlos ToutouzasCardiology Department and University Cardiology Clinic, Hippokration Hospital of Athens, GreeceBackground: The cardioprotective role of hormonal replacement therapy remains in doubt, but interest is increasing in the vascular effects of estrogens especially in coronary circulation.Methods: Coronary blood flow (CBF was measured in 24 postmenopausal women (age 55 ± 3 years, whose coronary arteries appeared angiographically normal, during incremental atrial pacing (AP before and 20 minutes after intracoronary administration of either 75 ng/mL 17-β estradiol (treated group, n = 18 or 0.9% saline (controls, n = 6.Results: Before estrogen, no differences in the coronary vasomotor responses at AP between the two groups (p = NS could be detected. After estrogen, in the treated group, at the peak of the second AP, the coronary artery diameter decreased by 0.17 mm (p < 0.005 while the CBF increased by 61 mL/min (p < 0.05. These changes differed significantly from thoseobserved at the peak of first AP (p < 0.001 for both cases. In contrast, in the control group no such changes were observed. The endothelin-1 (ET-1 levels in the coronary sinus were significantly reduced after estrogen infusion, which was negatively correlated with the degree of coronary artery constriction (r = −0.40, p = 0.03 and positively correlated with the increase in CBF (r = 0.54, p = 0.01.Conclusions: In postmenopausal women without coronary artery disease, the intracoronary estrogen infusion mediates a greater increase in CBF and is positively correlated with the reduction of the coronary sinus ET-1 levels at the peak of AP.Keywords: estrogens, coronary blood flow, endothelin-1, coronary interventions

  10. Fully integrated high-speed intravascular optical coherence tomography/near-infrared fluorescence structural/molecular imaging in vivo using a clinically available near-infrared fluorescence-emitting indocyanine green to detect inflamed lipid-rich atheromata in coronary-sized vessels.

    Science.gov (United States)

    Lee, Sunki; Lee, Min Woo; Cho, Han Saem; Song, Joon Woo; Nam, Hyeong Soo; Oh, Dong Joo; Park, Kyeongsoon; Oh, Wang-Yuhl; Yoo, Hongki; Kim, Jin Won

    2014-08-01

    Lipid-rich inflamed coronary plaques are prone to rupture. The purpose of this study was to assess lipid-rich inflamed plaques in vivo using fully integrated high-speed optical coherence tomography (OCT)/near-infrared fluorescence (NIRF) molecular imaging with a Food and Drug Administration-approved indocyanine green (ICG). An integrated high-speed intravascular OCT/NIRF imaging catheter and a dual-modal OCT/NIRF system were constructed based on a clinical OCT platform. For imaging lipid-rich inflamed plaques, the Food and Drug Administration-approved NIRF-emitting ICG (2.25 mg/kg) or saline was injected intravenously into rabbit models with experimental atheromata induced by balloon injury and 12- to 14-week high-cholesterol diets. Twenty minutes after injection, in vivo OCT/NIRF imaging of the infrarenal aorta and iliac arteries was acquired only under contrast flushing through catheter (pullback speed up to ≤20 mm/s). NIRF signals were strongly detected in the OCT-visualized atheromata of the ICG-injected rabbits. The in vivo NIRF target-to-background ratio was significantly larger in the ICG-injected rabbits than in the saline-injected controls (Pfluorescence reflectance imaging, which correlated well with the in vivo target-to-background ratios (Pfluorescence microscopy, and histopathology also corroborated the in vivo imaging findings. Integrated OCT/NIRF structural/molecular imaging with a Food and Drug Administration -approved ICG accurately identified lipid-rich inflamed atheromata in coronary-sized vessels. This highly translatable dual-modal imaging approach could enhance our capabilities to detect high-risk coronary plaques. © 2014 American Heart Association, Inc.

  11. Congenital anomalies of the coronary arteries: imaging with contrast-enhanced, multidetector computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, Rainer; Froehner, Steffen; Wagner, Matthias; Brunner, Horst; Cherevatyy, Oleg; Christopoulos, Georgios [Herz- und Gefaessklinik GmbH, Department of Radiology, Bad Neustadt an der Saale (Germany); Brunn, Juergen; Gietzen, Frank; Kerber, Sebastian [Herz- und Gefaessklinik GmbH, Department of Cardiology, Bad Neustadt an der Saale (Germany); Fellner, Franz [Oberoesterreichische Landesnervenklinik, Department of Radiology, Linz (Austria)

    2005-06-01

    The objective of this study is to evaluate multidetector CT (MDCT) in detecting and characterizing anomalous coronary arteries. Forty-four patients with anomalies of the coronaries were selected from a total of 1758 individuals examined with ECG-gated 4- and 16-row MDCT including thin MIP, MPR and VRT post-processing. Twenty-eight patients showed origin and course anomalies of the central coronary segments, and in this subgroup 13 were judged as ''malignant'' because of interarterial courses between the aortic root and the pulmonary trunk, either of the right coronary artery (n=11) or the left coronary artery (n=2). Twelve non-hemodynamic anomalies were found, affecting the coronary origins only (n=10) or the peripheral vessels courses (n=2). Four arteriovenous fistulas were present, all of them with complex arterial feeders. Regardless of vessel anatomy, coronary opacification was always possible by means of the systemic contrast agent, and the aberrant coronary arteries were visualized synoptically in direct relation to the great mediastinal vessels. In contrast to MDCT, selective cannulation and final diagnosis was possible in only 11 of the 20 catheter angiograms performed (accuracy of 55.0%). In conclusion, its non-invasiveness and precise visualization makes MDCT the standard of reference for evaluating anomalous coronary arteries. (orig.)

  12. Coronary Arteries Segmentation Based on the 3D Discrete Wavelet Transform and 3D Neutrosophic Transform

    Directory of Open Access Journals (Sweden)

    Shuo-Tsung Chen

    2015-01-01

    Full Text Available Purpose. Most applications in the field of medical image processing require precise estimation. To improve the accuracy of segmentation, this study aimed to propose a novel segmentation method for coronary arteries to allow for the automatic and accurate detection of coronary pathologies. Methods. The proposed segmentation method included 2 parts. First, 3D region growing was applied to give the initial segmentation of coronary arteries. Next, the location of vessel information, HHH subband coefficients of the 3D DWT, was detected by the proposed vessel-texture discrimination algorithm. Based on the initial segmentation, 3D DWT integrated with the 3D neutrosophic transformation could accurately detect the coronary arteries. Results. Each subbranch of the segmented coronary arteries was segmented correctly by the proposed method. The obtained results are compared with those ground truth values obtained from the commercial software from GE Healthcare and the level-set method proposed by Yang et al., 2007. Results indicate that the proposed method is better in terms of efficiency analyzed. Conclusion. Based on the initial segmentation of coronary arteries obtained from 3D region growing, one-level 3D DWT and 3D neutrosophic transformation can be applied to detect coronary pathologies accurately.

  13. Coronary arteries segmentation based on the 3D discrete wavelet transform and 3D neutrosophic transform.

    Science.gov (United States)

    Chen, Shuo-Tsung; Wang, Tzung-Dau; Lee, Wen-Jeng; Huang, Tsai-Wei; Hung, Pei-Kai; Wei, Cheng-Yu; Chen, Chung-Ming; Kung, Woon-Man

    2015-01-01

    Most applications in the field of medical image processing require precise estimation. To improve the accuracy of segmentation, this study aimed to propose a novel segmentation method for coronary arteries to allow for the automatic and accurate detection of coronary pathologies. The proposed segmentation method included 2 parts. First, 3D region growing was applied to give the initial segmentation of coronary arteries. Next, the location of vessel information, HHH subband coefficients of the 3D DWT, was detected by the proposed vessel-texture discrimination algorithm. Based on the initial segmentation, 3D DWT integrated with the 3D neutrosophic transformation could accurately detect the coronary arteries. Each subbranch of the segmented coronary arteries was segmented correctly by the proposed method. The obtained results are compared with those ground truth values obtained from the commercial software from GE Healthcare and the level-set method proposed by Yang et al., 2007. Results indicate that the proposed method is better in terms of efficiency analyzed. Based on the initial segmentation of coronary arteries obtained from 3D region growing, one-level 3D DWT and 3D neutrosophic transformation can be applied to detect coronary pathologies accurately.

  14. Reduced glomerular filtration rate as a predictor of coronary artery ...

    African Journals Online (AJOL)

    Tarek A. Ghonemy

    2016-07-09

    Jul 9, 2016 ... Internal Medicine Department, Nephrology Unit, Zagazig University ... glomerular filtration rate (eGFR) and risk of coronary artery disease ... ing of eGFR may have a pivotal role in early detection and management of CAD in those types of ..... position statement from kidney disease improving global out-.

  15. CURRENT APPROACHES TO EVALUATION OF THE MULTIVESSEL CORONARY ATHEROSCLEROSIS IN PATIENTS WITH CHRONIC ISCHEMIC HEART DISEASE

    Directory of Open Access Journals (Sweden)

    D. N. Perutsky

    2011-01-01

    Full Text Available Aim. To determine the validity of stress echocardiography by fractional reserve blood flow (FFR as the reference method in detection of coronary arteries requiring revascularization, as well as to optimize the determination of the functional significance of coronary artery lesions in patients with multivessel coronary atherosclerosis. Material and methods. Patients (n=36 with stable angina class 2-3 with multivessel coronary atherosclerosis were included into the study. Stress echocardiography with dobutamine or exercise test (treadmill was performed in all patients. Selective coronary angiography with subsequent evaluation of FFR was carried out in patients with a positive result of stress echocardiography. Totally 108 arteries (87 with stenosing atherosclerosis were assessed.  Results. According to coronary angiography bi-vessel and three-vessel damages were revealed in 21 (58% and 15 (42% patients, respectively. Method of stress echocardiography as compared with FFR shown sensitivity — 58%, specificity — 95%, positive predictive value — 87%, positive predictive value of a negative result — 17%. Method of coronary angiography (as a method to detect significant stenosis by visual assessment of coronary artery as compared with FFR demonstrated sensitivity 100%, specificity — 30%, positive predictive value — 42%. Conclusion. Stress echocardiography for noninvasive patient examination improves the accuracy of determination for the need and extent of revascularization.

  16. Myocardial bridging: evaluation with multislice computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Barros, M.V.L. de; Rabelo, D.R.; Nunes, M.C.P.; Siqueira, M.H.A. [Mater Dei Hospital, Belo Horizonte, MG (Brazil)

    2012-04-15

    Myocardial bridging (MB) is defined as a segment of a major epicardial coronary artery that proceeds intramurally through the myocardium beneath the muscle bridge. Although MB is clinically silent in most cases, it has been associated with myocardial ischemia, myocardial infarction, arrhythmia, and sudden death. Conventional coronary angiography (CCA) is the gold standard for detection, but it is invasive and may not be sensitive enough to detect a thin bridge. Recently, multislice computed tomography coronary angiography (MCTCA) have made possible the clear detection of the entire running courses of coronary arteries and the MB itself. Objective: To evaluate the prevalence MB in patients suspect to coronary artery disease submitted to MCTCA and assessing the predictive value of this method in the midterm. Methods: 498 consecutive patients were examined by MCTCA for the diagnosis of coronary artery disease and followed for a mean follow-up of 17 months for the occurrence of cardiovascular events (death, hospitalization and / or revascularization myocardial). Results: The mean age of patients was 58.4 ± 12.5 years old, 74.3% male. Among the patients, 6,02% (30 patients) showed MB. The major indications were angina pectoris in 45,8% and positive stress testing in 33,3%. 62,5% showed absent atherosclerotic disease and only 1 patient showed moderade descending anterior stenosis. During the follow-up none patient showed hard events. Conclusion: Patients with MB could present with angina pectoris and positive stress testing and showed midterm excellent prognosis. MCTCA is an alternative noninvasive imaging tool that allows for easy and accurate evaluation of MB.

  17. A rare anomaly: Double right coronary artery

    Directory of Open Access Journals (Sweden)

    Dursun Çayan Akkoyun

    2013-01-01

    Full Text Available Coronary artery anomalies are rare anomalies. Theseare usually asymptomatic and are discovered incidentally.Double right coronary artery (RCA is a rare coronaryartery anomaly. Although there is controversy aboutidentification and classification of double RCA, it is oftena benign condition, but it can be complicated by atherosclerosisand can lead to serious conditions such asmyocardial infarction (MI and may be accompanied byother anomalies. In our case, double RCA were detectedin coronary angiography for acute anterior MI, and in thenext session successful percutaneous coronary interventionwas performed.Key words: Coronary anomaly, coronary angiography,coronary stenosis

  18. Current status of hybrid coronary revascularization.

    Science.gov (United States)

    Jaik, Nikhil P; Umakanthan, Ramanan; Leacche, Marzia; Solenkova, Natalia; Balaguer, Jorge M; Hoff, Steven J; Ball, Stephen K; Zhao, David X; Byrne, John G

    2011-10-01

    Hybrid coronary revascularization combines coronary artery bypass surgery with percutaneous coronary intervention techniques to treat coronary artery disease. The potential benefits of such a technique are to offer the patients the best available treatments for coronary artery disease while minimizing the risks of the surgery. Hybrid coronary revascularization has resulted in the establishment of new 'hybrid operating suites', which incorporate and integrate the capabilities of a cardiac surgery operating room with that of an interventional cardiology laboratory. Hybrid coronary revascularization has greatly augmented teamwork and cooperation between both fields and has demonstrated encouraging as well as good initial outcomes.

  19. Genetic analysis of Porphyromonas gingivalis (fimA), Aggregatibacter actinomycetemcomitans, and red complex in coronary plaque.

    Science.gov (United States)

    Mahendra, Jaideep; Mahendra, Little; Felix, John; Romanos, Georgios E

    2014-08-01

    The objective of the present study was to detect the presence of Porphyromonas gingivalis (fimA), Aggregatibacter actinomycetemcomitans, and red complex in the coronary plaque of patients with coronary artery disease. The study population consisted of 51 patients with chronic periodontitis undergoing coronary artery bypass grafting. DNA was extracted from subgingival and coronary atherosclerotic plaque samples. Polymerase chain reaction was used to amplify the part of 16S rRNA gene to detect the presence of Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis (fimA), Porphyromonas gingivalis, Tannerella forsythia, and Treponema denticola. Aggregatibacter actinomycetemcomitans, Tannerella forsythia, Porphyromonas gingivalis, Porphyromonas gingivalis (fimA), and Treponema denticola were detected in 0%, 31.4%, 45.1%, 39.2%, and 51% of the atherosclerotic plaque samples, respectively. In both subgingival and coronary atherosclerotic plaque samples, Tannerella forsythia was detected in 19.6%, Porphyromonas gingivalis in 39.2%, Porphyromonas gingivalis (fimA) in 33.3%, and Treponema denticola in 35.3% of the samples. The study confirmed the detection of red complex bacteria in coronary plaque samples. However Aggregatibacter actinomycetemcomitans could not be detected in these samples. © 2013 Wiley Publishing Asia Pty Ltd.

  20. Comparative study of coronary plaque and stenosis: CT versus MR angiography

    International Nuclear Information System (INIS)

    Liu Xin; Zhao Xihai; Cheng Liuquan; Zhao Shaohong; Cai Zulong; Cai Youquan; Yang Li

    2006-01-01

    Objective: To investigate the effect of coronary plaque composition on the extent of stenosis and compare the accuracies of coronary CTA and MRA in detecting significant stenosis (≥50%) caused by different composition plaques. Methods: Thirty patients with coronary heart disease were examined with coronary CTA, MRA and conventional coronary, angiography (CAG) within two weeks. CTA and MRA were performed with a 16-slice CT scanner and hreathhold 3D FIESTA sequence respectively. The coronary plaques were grouped as non-calcified and calcified plaque on CTA images. The accuracies and agreement of CTA and MRA in detecting significant stenosis were evaluated by two experienced radiologists independently using CAG as reference. Results: Fifty-three plaques were detected on CTA. Twenty-eight were non-calcified and the other 25 were calcified. Twenty-one of 28 non-calcified plaques caused significant stenosis on CAG. The sensitivity and specificity of CTA and MRA in detecting significant stenosis were 85.7%, 85.7% and 47.6%, 71.4%, respectively, CTA showed good agreement with CAG (K=0.65). Six of 25 calcified plaques caused significant stenosis on CAG. The sensitivity and specificity of CTA and MRA in detecting significant stenosis were 83.3%, 31.6% and 83.3%, 73.7%, respectively, MRA showed moderate agreement with CAG (K=0.46). Conclusion: CTA was accurate for detecting non-calcified plaque and stenosis, while MRA had advantage to evaluate lumen with severe calcified plaque. (authors)

  1. [Expression of proBNP and NT-proBNP in Sudden Death of Coronary Heart Disease].

    Science.gov (United States)

    Zeng, Q; Sun, R F; Li, Z; Zhai, L Q; Liu, M Z; Guo, X J; Gao, C R

    2017-10-01

    To study the expression change of pro-brain natriuretic peptide (proBNP) and N-terminal pro-brain natriuretic peptide (NT-proBNP) in sudden death of coronary atherosclerotic heart disease, and to explore its application in forensic diagnosis. Myocardial and blood samples were collected from normal control group, sudden death of coronary atherosclerotic heart disease group and single coronary stenosis group (20 cases in each group). The expression of proBNP in myocardial samples were detected by immunohistochemical staining and Western blotting, and that of BNP mRNA were detected by reverse transcription PCR (RT-PCR). The content of NT-proBNP in plasma were detected by ELISA. Immunohistochemical staining showed positive expression of proBNP in both sudden death of coronary atherosclerotic heart disease group and single coronary stenosis group. There was no positive expression in normal control group. For sudden death of coronary atherosclerotic heart disease group and single coronary stenosis group, the relative expression of proBNP protein and BNP mRNA in myocardial tissue and the NT-proBNP content in plasma were higher than that of normal control group ( P heart disease group was higher than that of single coronary stenosis group ( P heart disease and determine whether the sudden death due to coronary atherosclerotic heart disease. Copyright© by the Editorial Department of Journal of Forensic Medicine

  2. Sensitivity and specificity of thallium-201 perfusion scintigrams under exercise in the diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Verani, M.S.; Marcus, M.L.; Razzak, M.A.; Ehrhardt, J.C.

    1978-01-01

    The specificity and sensitivity of thallium-201 myocardial perfusion imaging (MPI), under exercise, in patients with suspected coronary-obstructive disease was compared with graded exercise ECG tests (GTX) in patients with angiographically normal (N = 34) and obstructed (N = 48) coronary arteries. Of the 34 patients with normal coronaries, only one had a perfusion defect on the MPI (specificity 97%). Of the 48 patients with coronary obstructive disease (>50% obstruction of at least one coronary vessel), MPI was positive in 38 (sensitivity 79%). In contrast, the GTX had a specificity of 62% and sensitivity of 88% if nondiagnostic GTX tests are excluded. When the MPI and the GTX were used in combination, however, the sensitivity of detecting patients with coronary obstructive disease was increased to 94% (p < 0.01). The MPI was particularly useful in the evaluation of the 26 patients with nondiagnostic GTX. In this group, 24 of the 26 patients were correctly identified by the MPI with respect to the presence or absence of coronary-obstructive disease. In the 14 patients with a history of classical angina but with normal coronaries, the MPI was negative in 13 and positive in one, thus suggesting that in the majority of these patients transient transmural myocardial ischemia probably does not occur during exercise. The presence or absence of angiographically demonstrable coronary collateral vessels did not seem to influence the exercise MPI in patients with coronary-obstructive disease. Thus, although the MPI does not correctly identify all patients with either coronary-obstructive disease or normal coronary arteries, it is helpful in patients who have a nondiagnostic GTX. Furthermore, when used in combination with the GTX, the MPI significantly increases the likelihood that significant coronary-obstructive disease is present when both tests are positive, and that coronary disease is absent when both tests are negative

  3. Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique

    International Nuclear Information System (INIS)

    Tsai, I.C.; Lee, Tain; Chen, Min-Chi; Fu, Yun-Ching; Jan, Sheng-Lin; Wang, Chung-Chi; Chang, Yen

    2007-01-01

    Multidetector CT (MDCT) seems to be a promising tool for detection of neonatal coronary arteries, but whether the ECG-gated or non-ECG-gated technique should be used has not been established. To compare the detection rate and image quality of neonatal coronary arteries on MDCT using ECG-gated and non-ECG-gated techniques. Twelve neonates with complex congenital heart disease were included. The CT scan was acquired using an ECG-gated technique, and the most quiescent phase of the RR interval was selected to represent the ECG-gated images. The raw data were then reconstructed without the ECG signal to obtain non-ECG-gated images. The detection rate and image quality of nine coronary artery segments in the two sets of images were then compared. A two-tailed paired t test was used with P values <0.05 considered as statistically significant. In all coronary segments the ECG-gated technique had a better detection rate and produced images of better quality. The difference between the two techniques ranged from 25% in the left main coronary artery to 100% in the distal right coronary artery. For neonates referred for MDCT, if evaluation of coronary artery anatomy is important for the clinical management or surgical planning, the ECG-gated technique should be used because it can reliably detect the coronary arteries. (orig.)

  4. Diagnosing coronary artery disease after a positive coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Nissen, L; Winther, S; Westra, J

    2018-01-01

    Aims: Perfusion scans after coronary computed tomography angiography (CCTA) in patients with suspected coronary artery disease (CAD) may reduce unnecessary invasive coronary angiographies (ICAs). However, the diagnostic accuracy of perfusion scans after primary CCTA is unknown. The aim...

  5. Vessel dilatation in coronary angiograms

    International Nuclear Information System (INIS)

    Hinterauer, L.; Goebel, N.

    1983-01-01

    Amongst 166 patients with aneurysms, ectasia or megaloarteries shown on coronary angiograms, 86.1% had dilated vessels as part of generalised coronary sclerosis (usually in patients with three-vessel disease). In 9%, dilatation was of iatrogenic origin and in 4.8% it was idiopathic. One patient had Marfan's syndrome. Amongst 9 000 patients, there were eight with megalo-arteries without stenosis; six of these had atypical angina and three suffered an infarct. Patients with definite dilatation of the coronary artery and stagnation of contrast flow required treatment. (orig.) [de

  6. Vessel dilatation in coronary angiograms

    Energy Technology Data Exchange (ETDEWEB)

    Hinterauer, L.; Goebel, N.

    1983-11-01

    Amongst 166 patients with aneurysms, ectasia or megaloarteries shown on coronary angiograms, 86.1% had dilated vessels as part of generalised coronary sclerosis (usually in patients with three-vessel disease). In 9%, dilatation was of iatrogenic origin and in 4.8% it was idiopathic. One patient had Marfan's syndrome. Amongst 9 000 patients, there were eight with megalo-arteries without stenosis; six of these had atypical angina and three suffered an infarct. Patients with definite dilatation of the coronary artery and stagnation of contrast flow required treatment.

  7. PLACENTAL GROWTH FACTOR AND CORONARY NEOANGIOGENESIS IN CORONARY HEART DISEASE

    Directory of Open Access Journals (Sweden)

    M. V. Tulikov

    2013-01-01

    Full Text Available Neoangiogenesis in coronary heart disease is a protective reaction aimed to improve ischemic myocardial perfusion, by increasing the number and size of arterial collaterals. Placental growth factor (PlGF is one of the key peptides regulating angiogenic processes in atherosclerosis. In particular, a number of investigators have shown that injection of recombinant PlGF into the system or regional blood flow can stimulate neoangiogenesis. On the other hand, there is evidence confirming the involvement of PlGF in the progression of atherosclerosis and in the development of acute coronary syndrome. In this connection, the problem of investigating the efficiency and safety of possible use of PlGF preparations, as well as its place in the diagnosis of coronary heart disease and acute coronary syndrome remains urgent

  8. Thallium-201 scintigraphy in diagnosis of coronary stenosis

    International Nuclear Information System (INIS)

    Corne, R.A.; Gotsman, M.S.; Weiss, A.; Enlander, D.; Samuels, L.D.; Salomon, J.A.; Warshaw, B.; Atlan, H.

    1979-01-01

    The sensitivity of rest and exercise thallium-201 scintigraphy for the detection of significant coronary artery disease and myocardial ischaemia was compared with rest and exercise electrocardiography in 46 patients with chest pain. Of 26 patients with greater that 70 per cent coronary stenosis, 16 had abnormal rest thallium-201 scintigrams and 13 had Q waves. Myocardial perfusion defects in the resting scintigram correlated very well with evidence of previous myocardial infarction (16 of 17 patients, 94%) significant Q waves were present in 13 of these 17 patients (76%). After exercise, abnormal thallium-201 scintigrams consistent with ischaemia were found in 21 patients (81%). Abnormal exercise electrocardiograms were present in 15 patients (58%). The combination of abnormal exercise thallium-201 scintigrams or exercise electrocardiograms (23/26, 88%) exceeded abnormal exercise electrocardiograms alone (15/26, 58%). The two procedures were thus complementary. Abnormal rest or exercise thallium-201 scintigrams were obtained in 25/26 patients (96%) compared with abnormal rest or exercise electrocardiograms in 21/26 patients (84%). Twenty patients with less than 50 per cent coronary stenosis had normal rest thallium-201 scintigrams and no Q waves. Two had abnormal exercise thallium-201 scintigrams and 7 had abnormal exercise electrocardiograms. Thus,exercise thallium scintigraphy has higher sensitivity than exercise electrocardiography in detecting exercise induced ischaemia and is more specific. Scintigraphy appears to have a higher sensitivity than electrocardiography in detecting coronary artery disease. (author)

  9. Spontaneous Coronary Dissection: “Live Flash” Optical Coherence Tomography Guided Angioplasty

    Science.gov (United States)

    Bento, Angela Pimenta; Fernandes, Renato Gil dos Santos Pinto; Neves, David Cintra Henriques Silva; Patrício, Lino Manuel Ribeiro; de Aguiar, José Eduardo Chambel

    2016-01-01

    Optical Coherence tomography (OCT) is a light-based imaging modality which shows tremendous potential in the setting of coronary imaging. Spontaneous coronary artery dissection (SCAD) is an infrequent cause of acute coronary syndrome (ACS). The diagnosis of SCAD is made mainly with invasive coronary angiography, although adjunctive imaging modalities such as computed tomography angiography, IVUS, and OCT may increase the diagnostic yield. The authors describe a clinical case of a young woman admitted with the diagnosis of ACS. The ACS was caused by SCAD detected in the coronary angiography and the angioplasty was guided by OCT. OCT use in the setting of SCAD has been already described and the true innovation in this case was this unique use of OCT. The guidance of angioplasty with live and short images was very useful as it allowed clearly identifying the position of the guidewires at any given moment without the use of prohibitive amounts of contrast. PMID:26989520

  10. The usefulness of planar thallium myocardial perfusion imaging in the diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Johannesen, K.A.; Andersen, K.; Foelling, M.; Vik-Mo, H.

    1991-01-01

    Stress thallium scintigraphy was performed in 60 patients with chest pain of uncertain origin. Myocardial ischemia was identified in 91% og the 47 patients who had angiographically significant coronary artery stenosis. Sensitivity of thallium scintigraphy was highest in patients with stenosis in the left descending coronary artery (LAD); 91% of the patients had abnormal thallium as compared with 67% of the patients with normal LAD, but significant stenosis in the circumflex artery and/or the right coronary artery. Perfusion defects in the circumflex or right coronary artery regions were detected in only 50% of the patients with multiple vessel disease. The authors conclude that stress thallium scintigraphy is a useful diagnostic procedure in patients with chest pain of uncertain origin and identifies the patients to be selected for coronary artery angiography. 15 refs., 2 figs., 2 tabs

  11. Coronary angiography using synchrotron radiation

    International Nuclear Information System (INIS)

    Akatsuka, Takao; Hiranaka, Yukio; Takeda, Tohru; Hyodo, Kazuyuki.

    1990-01-01

    Invasive coronary angiography is the imaging technique of choice for diagnosis of ischemic heart disease. Recently, the application of synchrotron radiation in coronary angiography has been investigated in the world, with the aim of developing the noninvasive technique for visualizing the heart. In this article, backgrounds and present situation of coronary angiography using synchrotron radiation are reviewed. Firstly, visual imaging techniques of the cardiovascular system are discussed in terms of angiography and digital subtraction angiography (DSA). Conventional temporal, energy, and hybrid subtraction modes used in DSA are referred to. Secondly, the application of synchrotron radiation is presented, focusing on the property of synchrotron radiation and K-edge subtraction angiography. Two kinds of synchrotron radiation beam methods are outlined. Interpretation of image data and various subtraction procedures remain unestablished. There is much to be done before coronary angiography using synchrotron radiation comes into a clinical practice. (N.K.)

  12. Coronary Computed Tomography Angiography (CTA)

    Science.gov (United States)

    ... coronary arteries, may also be administered as a tablet or spray underneath your tongue. While lying on ... the scanner at one time such as with MRI. If an intravenous contrast material is used, you ...

  13. Pronounced Coronary Arteriosclerosis in Cirrhosis

    DEFF Research Database (Denmark)

    Danielsen, Karen V; Wiese, Signe; Hove, Jens

    2018-01-01

    factors including smoking, type 2 diabetes, hypertension, gender, or hypercholesterolemia. Coronary artery calcium-score was associated with diastolic dysfunction, lateral e´ (p = 0.025), but not with other markers of cardiac dysfunction. During a median follow-up of 25 months 12 patients (21%) died......BACKGROUND: The relation between excessive alcohol consumption and coronary arteriosclerosis has remained controversial. The etiology of cirrhosis has been considered a substantial risk factor for development of arteriosclerotic lesions. The coronary artery calcium-score derived from coronary CT...... and women: 136 vs. 0 HU; p alcohol-related cirrhosis was significantly higher than in nonalcohol-related cirrhosis (362 vs. 46 HU, p 

  14. Assessment of coronary artery aneurysms in paediatric patients with Kawasaki disease by multidetector row CT angiography: feasibility and comparison with 2D echocardiography

    International Nuclear Information System (INIS)

    Chu, W.C.W.; Lam, W.W.M.; Mok, G.C.F.; Yam, M.; Sung, R.Y.T.

    2006-01-01

    Transthoracic ECHO is the locally accepted method for coronary surveillance of patients with Kawasaki disease but it may have limited visualization in the older child. To assess the feasibility of multidetector CT (MDCT) angiography in the follow-up of coronary artery aneurysms in children with previous Kawasaki disease. Six children (5 boys, 1 girl; mean age 11.5 years) with known Kawasaki disease and coronary artery involvement underwent CT coronary angiography using 16-detector MDCT. The visualized lengths and diameter of all coronary segments were measured. The number, size and location of coronary artery aneurysms were recorded and compared with recent ECHO. Twelve coronary artery aneurysms (seven saccular, five fusiform) were identified by MDCT angiography. One saccular aneurysm at the junction of the distal right coronary artery and posterior descending artery was not detected by ECHO while the remaining six in proximal segments were detected by both modalities. Two of five fusiform aneurysms were not detected by ECHO due to their small sizes. Excellent agreement was found between CT and ECHO for maximal diameter and length of the visualized aneurysms. MDCT angiography accurately defines coronary artery aneurysms. It is more sensitive for detecting aneurysms at distal coronary segments and fusiform aneurysms of small size

  15. Physiologic assessment of coronary artery fistula

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, N.C.; Beauvais, J. (Creighton Univ., Omaha, NE (USA))

    1991-01-01

    Coronary artery fistula is an uncommon clinical entity. The most common coronary artery fistula is from the right coronary artery to the right side of the heart, and it is less frequent to the pulmonary artery. The effect of a coronary artery fistula may be physiologically significant because of the steal phenomenon resulting in coronary ischemia. Based on published reports, it is recommended that patients with congenital coronary artery fistulas be considered candidates for elective surgical correction to prevent complications including development of congestive heart failure, angina, subacute bacterial endocarditis, myocardial infarction, and coronary aneurysm formation with rupture or embolization. A patient is presented in whom treadmill-exercise thallium imaging was effective in determining the degree of coronary steal from a coronary artery fistula, leading to successful corrective surgery.

  16. Physiologic assessment of coronary artery fistula

    International Nuclear Information System (INIS)

    Gupta, N.C.; Beauvais, J.

    1991-01-01

    Coronary artery fistula is an uncommon clinical entity. The most common coronary artery fistula is from the right coronary artery to the right side of the heart, and it is less frequent to the pulmonary artery. The effect of a coronary artery fistula may be physiologically significant because of the steal phenomenon resulting in coronary ischemia. Based on published reports, it is recommended that patients with congenital coronary artery fistulas be considered candidates for elective surgical correction to prevent complications including development of congestive heart failure, angina, subacute bacterial endocarditis, myocardial infarction, and coronary aneurysm formation with rupture or embolization. A patient is presented in whom treadmill-exercise thallium imaging was effective in determining the degree of coronary steal from a coronary artery fistula, leading to successful corrective surgery

  17. Is there an indication for computed tomography and magnetic resonance imaging in the evaluation of coronary artery bypass grafts?

    NARCIS (Netherlands)

    Dikkers, R.; van der Zaag-Loonen HJ, [No Value; Willems, T.P.; Post, W.J.; Oudkerk, M.

    2009-01-01

    This meta-analysis evaluates the diagnostic accuracy of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) for bypass graft occlusion and stenosis detection compared with coronary angiography in post-coronary artery bypass graft patients. The indication for noninvasive

  18. Abnormalities of the Coronary Arteries in Children: Looking beyond the Origins.

    Science.gov (United States)

    Saling, Lauren J; Raptis, Demetrios A; Parekh, Keyur; Rockefeller, Toby A; Sheybani, Elizabeth F; Bhalla, Sanjeev

    2017-10-01

    Coronary arterial abnormalities are uncommon findings in children that have profound clinical implications. Although anomalies of the coronary origins are well described, there are many other disease processes that affect the coronary arteries. Immune system-mediated diseases (eg, Kawasaki disease, polyarteritis nodosa, and other vasculiditides) can result in coronary arterial aneurysms, strictures, and abnormal tapering of the vessels. Because findings at imaging are an important component of diagnosis in these diseases, the radiologist's understanding of them is essential. Congenital anomalies may present at varying ages, and findings in hemodynamically significant anomalies, such as fistulas, are key for both diagnosis and preoperative planning. Pediatric heart surgery can result in wide-ranging postoperative imaging appearances of the coronary arteries and also predisposes patients to a multitude of complications affecting the heart and coronary arteries. In addition, although rare, accidental trauma can lead to injury of the coronary arteries, and awareness and detection of these conditions are important for diagnosis in the acute setting. Patients with coronary arterial conditions at presentation may range from being asymptomatic to having findings of myocardial infarction. Recognition of the imaging findings is essential to direct appropriate treatment. © RSNA, 2017.

  19. HELICOBACTER PYLORI-ASSOCIATED INFLAMMATION IN PATIENTS WITH ACUTE CORONARY SYNDROME

    Directory of Open Access Journals (Sweden)

    O. N. Pavlov

    2014-07-01

    Full Text Available The aim – assessment of the prevalence of seropositivity to Helicobacter pylori infection and laboratory comparative study of the peripheralblood in patients depending on the course of coronary heart disease (CHD.Materials and methods. Observation of 100 patients with coronary artery disease and 40 control patients is presented. Investigation indicatorsof clinical blood tests, biochemical blood analysis and determination of immunoglobulin antibody titer against Helicobacter pylori.Results. In patients with coronary artery disease signs of systemic inflammation associated with the development of acute coronary syndrome are marked with increased antibody titers to infection Helicobacter pylori.Conclusion. A history of coronary artery disease in patients with Helicobacter pylori-associated gastroduodenal pathology should be considered as a factor that increases the likelihood of unstable coronary desease course. Detected in patients with coronary artery disease signs of systemic inflammation with an increase in titer of antibodies to Helicobacter pylori infection associated with development of acute coronary syndrome.

  20. Correlation between coronary computed tomographic angiography and fractional flow reserve

    DEFF Research Database (Denmark)

    Kristensen, Thomas Skaarup; Engstrøm, Thomas; Kelbæk, Henning

    2010-01-01

    Coronary CT angiography (CCTA) has become an important modality to evaluate the presence of coronary artery disease. Coronary artery stenosis of intermediate severity remains a therapeutic dilemma. Measurement of fractional flow reserve (FFR) during coronary angiography is the most established...

  1. The minimum coronary artery diameter in which coronary spasm can be identified by synchrotron radiation coronary angiography

    International Nuclear Information System (INIS)

    Matsushita, Shonosuke; Hyodo, Kazuyuki; Imazuru, Tomohiro; Tokunaga, Chiho; Sato, Fujio; Enomoto, Yoshiharu; Hiramatsu, Yuji; Sakakibara, Yuzuru

    2008-01-01

    Background: Coronary vasospasm is defined as a temporary, intense narrowing of the coronary conduit artery. It brings about ischemic chest pain and becomes one of the causes of myocardial infarction. Coronary spasms are divided into two categories. One is the coronary spasm of the conduit artery and the other is the coronary microvascular spasm. Although coronary spasms are diagnosed with the images of coronary angiography, microvascular spasms cannot be diagnosed because of the limitations of conventional angiographic systems. However, synchrotron radiation coronary angiography (SRCA) can identify coronary arteries down to 100 μm in diameter in the beating heart and 50 μm in arrested heart. Aim: The purpose of this study was to confirm whether microvascular spasms could be identified or not using SRCA, and then down that size identification was possible. Methods: The Langendorff perfusion system with isolated rat hearts was employed. Krebs-Henseleit solution (KH solution) was used as a perfusate. 10 mM of 4-aminopyridine (4-AP: a voltage-gated potassium channel blocker; spasm inducer) was added to the KH solution and maintained for 5 min. SRCA was performed at pre-, during and 10 min after cessation of the KH solution with 4-AP. Coronary spasms were defined as a temporal 75% reduction of coronary arterial diameter. Results and conclusion: Multiple sizes of coronary arteries showed coronary spasms. The minimum stenosed coronary artery size was 100 μm. Since coronary microvascular spasms are seen in the arterioles (50-400 μm), coronary microvascular spasms may be diagnosed with the use of synchrotron radiation coronary angiography

  2. Coronary calcium score as gatekeeper for 64-slice computed tomography coronary angiography in patients with chest pain: per-segment and per-patient analysis

    International Nuclear Information System (INIS)

    Palumbo, Anselmo Alessandro; Cademartiri, Filippo; Maffei, Erica; Martini, Chiara; Tarantini, Giuseppe; Di Tanna, Gian Luca; Berti, Elena; Grilli, Roberto; Casolo, Giancarlo; Brambilla, Valerio; Cerrato, Marcella; Rotondo, Antonio; Weustink, Annick C.; Mollet, Nico R.A.

    2009-01-01

    We sought to investigate the performance of 64-slice CT in symptomatic patients with different coronary calcium scores. Two hundred patients undergoing 64-slice CT coronary angiography for suspected coronary artery disease were enrolled into five groups based on Agatston calcium score using the Mayo Clinic risk stratification: group 1: score 0, group 2: score 1-10, group 3: score 11-100, group 4: score 101-400, and group 5: score > 401. Diagnostic accuracy for the detection of significant (≥50% lumen reduction) coronary artery stenosis was assessed on a per-segment and per-patient base using quantitative coronary angiography as the gold standard. For groups 1 through 5, sensitivity was 97, 96, 91, 90, 92%, and specificity was 99, 98, 96, 88, 90%, respectively, on a per-segment basis. On a per-patient basis, the best diagnostic performance was obtained in group 1 (sensitivity 100% and specificity 100%) and group 5 (sensitivity 95% and specificity 100%). Progressively higher coronary calcium levels affect diagnostic accuracy of CT coronary angiography, decreasing sensitivity and specificity on a per-segment base. On a per-patient base, the best results in terms of diagnostic accuracy were obtained in the populations with very low and very high cardiovascular risk. (orig.)

  3. Noninvasive Coronary Angiography using 64-Detector-Row Computed Tomography in Patients with a Low to Moderate Pretest Probability of Significant Coronary Artery Disease

    Energy Technology Data Exchange (ETDEWEB)

    Schlosser, T.; Mohrs, O.K.; Magedanz, A.; Nowak, B.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A. [Dept. of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen (Germany)

    2007-04-15

    Purpose: To evaluate the value of 64-detector-row computed tomography for ruling out high-grade coronary stenoses in patients with a low to moderate pretest probability of significant coronary artery disease. Material and Methods: The study included 61 patients with a suspicion of coronary artery disease on the basis of atypical angina or ambiguous findings in noninvasive stress testing and a class II indication for invasive coronary angiography (ICA). All patients were examined by 64-detector-row computed tomography angiography (CTA) and ICA. On a coronary segmental level, the presence of significant (>50% diameter) stenoses was examined. Results: In a total of 915 segments, CTA detected 62 significant stenoses. Thirty-four significant stenoses were confirmed by ICA, whereas 28 stenoses could not be confirmed by ICA. Twenty-two of them showed wall irregularities on ICA, and six were angiographically normal. Accordingly, on a coronary segmental basis, 28 false-positive and 0 false-negative findings resulted in a sensitivity of 100%, a specificity of 96.8%, a positive predictive value of 54.8%, and a negative predictive value of 100%. The diagnostic accuracy was 96.9%. Conclusion: Sixty-four-detector-row computed tomography reliably detects significant coronary stenoses in patients with suspected coronary artery disease and appears to be helpful in the selection of patients who need to undergo ICA. Calcified and non-calcified plaques are detected. Grading of stenoses in areas with calcification is difficult. Frequently, stenosis severity is overestimated by 64-detector-row computed tomography.

  4. Noninvasive Coronary Angiography using 64-Detector-Row Computed Tomography in Patients with a Low to Moderate Pretest Probability of Significant Coronary Artery Disease

    International Nuclear Information System (INIS)

    Schlosser, T.; Mohrs, O.K.; Magedanz, A.; Nowak, B.; Voigtlaender, T.; Barkhausen, J.; Schmermund, A.

    2007-01-01

    Purpose: To evaluate the value of 64-detector-row computed tomography for ruling out high-grade coronary stenoses in patients with a low to moderate pretest probability of significant coronary artery disease. Material and Methods: The study included 61 patients with a suspicion of coronary artery disease on the basis of atypical angina or ambiguous findings in noninvasive stress testing and a class II indication for invasive coronary angiography (ICA). All patients were examined by 64-detector-row computed tomography angiography (CTA) and ICA. On a coronary segmental level, the presence of significant (>50% diameter) stenoses was examined. Results: In a total of 915 segments, CTA detected 62 significant stenoses. Thirty-four significant stenoses were confirmed by ICA, whereas 28 stenoses could not be confirmed by ICA. Twenty-two of them showed wall irregularities on ICA, and six were angiographically normal. Accordingly, on a coronary segmental basis, 28 false-positive and 0 false-negative findings resulted in a sensitivity of 100%, a specificity of 96.8%, a positive predictive value of 54.8%, and a negative predictive value of 100%. The diagnostic accuracy was 96.9%. Conclusion: Sixty-four-detector-row computed tomography reliably detects significant coronary stenoses in patients with suspected coronary artery disease and appears to be helpful in the selection of patients who need to undergo ICA. Calcified and non-calcified plaques are detected. Grading of stenoses in areas with calcification is difficult. Frequently, stenosis severity is overestimated by 64-detector-row computed tomography

  5. Myocardial scintigraphy with 201thallium for the diagnosis of coronary heart disease and heart muscle disease

    International Nuclear Information System (INIS)

    Keller, E.

    1986-01-01

    This work gives an overview of the presently used methods of diagnostic and therapy of coronary heart disease. With the use of 105 patients the viability of scintigraphical and radiological studies were compared to each other. The thallium scintigraphy thereby achieves excellent results with a sensitivity of 95% of coronary heart disease (with a pre-determined exclusion of myocardial diseases). In three cases small vessel disease was detected which could not be detected by a coronary angiogram. The correct localization of coronary stenosis with thallium scintigraphy was attained in the area of LAD at 77% and in the avea of RCA at 74% fairly reliable, whereas the determination of circumflex artery (sensitivity 29%) was rather poor. Also, the excact determination of the extent of coronary sclerosis shows that with multiple vessel diseases the sensitivity clearly decreases (1-vessel 78%, 2-vessel 38%, 3-vessel 13%), whereby the various coronary stenoses probably appear differently in scintigraphs. A better study method for the exact determination of the extent of myocardial ischemia is offered by the single photon emission computer tomography (SPECT) with the use of a rotating gamma camera. In view of the differential diagnostic for coronary diseases myocardial scintigraphy still plays a major role in myocardial diseases. In my own research pathological storage patterns could be shown in 14 such cases. (orig./MG) [de

  6. In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT

    International Nuclear Information System (INIS)

    Steen, Henning; Andre, Florian; Korosoglou, Grigorios; Mueller, Dirk; Hosch, Waldemar; Kauczor, Hans-Ulrich; Giannitsis, Evangelos; Katus, Hugo A.

    2011-01-01

    Objective: We sought to investigate stent lumen visibility of 56 coronary stents with the newest 256-multi-slice-CT (256-MDCT) technology for different reconstruction algorithms in an in vitro model. Background: Early identification of in-stent restenosis (ISR) is important to avoid recurrent ischemia and prevent acute myocardial infarction (AMI). Since angiography has the disadvantage of high costs and its invasiveness, MDCT could be a convenient and safe non-invasive alternative for detection of ISR. Material and methods: Percentages of in-stent lumen diameter and in-stent signal attenuation (measured as contrast-to-noise ratio (CNR)) of 56 coronary stents (group A ≤2.5 mm; group B = 2.75-3.0 mm; group C = 3.5-4.0 mm) were evaluated in a coronary vessel in vitro phantom (iodine-filled plastic tubes) employing four different reconstruction algorithms (XCD, CC, CD, XCB) on a novel 256-MDCT (Philips-iCT, collimation = 128 mm x 0.625 mm; rotation time = 270 ms; tube current = 800 mA s with 120 kV). Analysis was conducted with the semi-automatical full-width-at-half-maximum (FWHM) method. P-values 60% for group C stents was significantly larger and CNR was significantly lower (both p 3.0 mm when analysed with cardio-dedicated sharp kernels, although clinical studies corroborating this claim should be performed. However, stents ≤3.0 mm reconstructed by soft kernels revealed insufficient in-stent lumen visualisation and should not be used in clinical practice. Further improvements in spatial and temporal image resolution as well as reductions of radiation exposure and image noise have to be accomplished for the ambitious goal of characterising both CT coronary artery anatomy and in-stent lumen.

  7. Coronary artery anomalies in Turner Syndrome.

    Science.gov (United States)

    Viuff, Mette H; Trolle, Christian; Wen, Jan; Jensen, Jesper M; Nørgaard, Bjarne L; Gutmark, Ephraim J; Gutmark-Little, Iris; Mortensen, Kristian H; Gravholt, Claus Højbjerg; Andersen, Niels H

    Congenital heart disease, primarily involving the left-sided structures, is often seen in patients with Turner Syndrome. Moreover, a few case reports have indicated that coronary anomalies may be more prevalent in Turner Syndrome than in the normal population. We therefore set out to systematically investigate coronary arterial anatomy by computed tomographic coronary angiography (coronary CTA) in Turner Syndrome patients. Fifty consecutive women with Turner Syndrome (mean age 47 years [17-71]) underwent coronary CTA. Patients were compared with 25 gender-matched controls. Coronary anomaly was more frequent in patients with Turner Syndrome than in healthy controls [20% vs. 4% (p = 0.043)]. Nine out of ten abnormal cases had an anomalous left coronary artery anatomy (absent left main trunk, n = 7; circumflex artery originating from the right aortic sinus, n = 2). One case had a tubular origin of the right coronary artery above the aortic sinus. There was no correlation between the presence of coronary arterial anomalies and karyotype, bicuspid aortic valve, or other congenital heart defects. Coronary anomalies are highly prevalent in Turner Syndrome. The left coronary artery is predominantly affected, with an absent left main coronary artery being the most common anomaly. No hemodynamically relevant coronary anomalies were found. Copyright © 2016 Society of Cardiovascular Computed Tomography. All rights reserved.

  8. Computed Tomographic Perfusion Improves Diagnostic Power of Coronary Computed Tomographic Angiography in Women

    DEFF Research Database (Denmark)

    Penagaluri, Ashritha; Higgins, Angela Y.; Vavere, Andrea L

    2016-01-01

    laboratories. Prevalence of flow-limiting CAD defined by invasive coronary angiography equal to 50% or greater with an associated single-photon emission computed tomography myocardial perfusion imaging defect was 45% (114/252) and 23% (30/129) in males and females, respectively. Patient-based diagnostic......Background-Coronary computed tomographic angiography (CTA) and myocardial perfusion imaging (CTP) is a validated approach for detection and exclusion of flow-limiting coronary artery disease (CAD), but little data are available on gender-specific performance of these modalities. In this study, we...... aimed to evaluate the diagnostic accuracy of combined coronary CTA and CTP in detecting flow-limiting CAD in women compared with men.  Methods and Results-Three hundred and eighty-one patients who underwent both CTA-CTP and single-photon emission computed tomography myocardial perfusion imaging...

  9. Transthoracic Doppler echocardiography – noninvasive diagnostic window for coronary flow reserve assessment

    Directory of Open Access Journals (Sweden)

    Dimitrow Paweł

    2003-04-01

    Full Text Available Abstract This review focuses on transthoracic Doppler echocardiography as noninvasive method used to assess coronary flow reserve (CFR in a wide spectrum of clinical settings. Transthoracic Doppler echocardiography is rapidly gaining appreciation as popular tool to measure CFR both in stenosed and normal epicardial coronary arteries (predominantly in left anterior descending coronary artery. Post-stenotic CFR measurement is helpful in: functional assessment of moderate stenosis, detection of significant or critical stenosis, monitoring of restenosis after revascularization. In the absence of stenosis in the epicardial coronary artery, decreased CFR enable to detect impaired microvascular vasodilatation in: reperfused myocardial infarct, arterial hypertension with or without left ventricular hypertrophy, diabetes mellitus, hypercholesterolemia, syndrome X, hypertrophic cardiomyopathy. In these diseases, noninvasive transthoracic Doppler echocardiography allows for serial CFR evaluations to explore the effect of various pharmacological therapies.

  10. The value of applying nitroglycerin in 3D coronary MR angiography with real-time navigation technique

    International Nuclear Information System (INIS)

    Hackenbroch, M.; Meyer, C.; Schmiedel, A.; Hofer, U.; Flacke, S.; Kovacs, A.; Schild, H.; Sommer, T.; Tiemann, K.; Skowasch, D.

    2004-01-01

    Purpose: Nitroglycerin administration results in dilation of epicardial coronary vessels and in an increase in coronary blood flow, and has been suggested to improve MR coronary angiography. This study evaluates systematically whether administration of nitroglycerin improves the visualization of coronary arteries and, as a result, the detection of coronary artery stenosis during free breathing 3D coronary MR angiography. Materials and Methods: Coronary MR angiography was performed in 44 patients with suspected coronary artery disease at a 1.5 Tesla System (Intera, Philips Medical Systems) (a) with and (b) without continuous administration of intravenous nitroglycerin at a dose rate of 2.5 mg/h, using an ECG gated gradient echo sequence with real-time navigator correction (turbo field echo, in-plane resolution 0.70 x 0.79 mm 2 , acquisition window 80 ms). Equivalent segments of the coronary arteries in the sequences with and without nitroglycerin were evaluated for visualized vessel length and diameter, qualitative assessment of visualization using a four point grading scale and detection of stenoses >50%. Catheter coronary angiography was used as a gold-standard. Results: No significant differences were found between scans with and without nitroglycerin as to average length of the contiguously visualized vessel length (p>0.05) and diameter (p>0.05). There was also no significant difference in the coronary MR angiography with and without nitroglycerin in the average qualitative assessment score of the visualization of LM, proximal LAD, proximal CX, and proximal and distal RCA (2.1±0.8 and 2.2±0.7; p> 0.05). Sensitivity (77% [17/22] vs. 82% [18/22] p>0.05) and specificity (72% [13/18] vs. 72% [13/18] p>0.05) for the detection of coronary artery stenosis also did not differ significantly between scans with and without intravenous administration of nitroglycerin. Conclusion: Administration of nitroglycerin does not improve visualization of the coronary arteries and

  11. Early results of coronary artery bypass grafting with coronary endarterectomy for severe coronary artery disease

    Directory of Open Access Journals (Sweden)

    Toischer Karl

    2009-09-01

    Full Text Available Abstract Background Despite the existence of controversial debates on the efficiency of coronary endarterectomy (CE, it is still used as an adjunct to coronary artery bypass grafting (CABG. This is particularly true in patients with endstage coronary artery disease. Given the improvements in cardiac surgery and postoperative care, as well as the rising number of elderly patient with numerous co-morbidities, re-evaluating the pros and cons of this technique is needed. Methods Patient demographic information, operative details and outcome data of 104 patients with diffuse calcified coronary artery disease were retrospectively analyzed with respect to functional capacity (NYHA, angina pectoris (CCS and mortality. Actuarial survival was reported using a Kaplan-Meyer analysis. Results Between August 2001 and March 2005, 104 patients underwent coronary artery bypass grafting (CABG with adjunctive coronary endarterectomy (CE in the Department of Thoracic-, Cardiac- and Vascular Surgery, University of Goettingen. Four patients were lost during follow-up. Data were gained from 88 male and 12 female patients; mean age was 65.5 ± 9 years. A total of 396 vessels were bypassed (4 ± 0.9 vessels per patient. In 98% left internal thoracic artery (LITA was used as arterial bypass graft and a total of 114 vessels were endarterectomized. CE was performed on right coronary artery (RCA (n = 55, on left anterior descending artery (LAD (n = 52 and circumflex artery (RCX (n = 7. Ninety-five patients suffered from 3-vessel-disease, 3 from 2-vessel- and 2 from 1-vessel-disease. Closed technique was used in 18%, open technique in 79% and in 3% a combination of both. The most frequent endarterectomized localization was right coronary artery (RCA = 55%. Despite the severity of endstage atherosclerosis, hospital mortality was only 5% (n = 5. During follow-up (24.5 ± 13.4 months, which is 96% complete (4 patients were lost caused by unknown address 8 patients died (cardiac

  12. Coronary artery analysis: Computer-assisted selection of best-quality segments in multiple-phase coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Chuan, E-mail: chuan@umich.edu; Chan, Heang-Ping; Hadjiyski, Lubomir M.; Chughtai, Aamer; Wei, Jun; Kazerooni, Ella A. [Department of Radiology, The University of Michigan, Ann Arbor, Michigan 48109-0904 (United States)

    2016-10-15

    Purpose: The authors are developing an automated method to identify the best-quality coronary arterial segment from multiple-phase coronary CT angiography (cCTA) acquisitions, which may be used by either interpreting physicians or computer-aided detection systems to optimally and efficiently utilize the diagnostic information available in multiple-phase cCTA for the detection of coronary artery disease. Methods: After initialization with a manually identified seed point, each coronary artery tree is automatically extracted from multiple cCTA phases using our multiscale coronary artery response enhancement and 3D rolling balloon region growing vessel segmentation and tracking method. The coronary artery trees from multiple phases are then aligned by a global registration using an affine transformation with quadratic terms and nonlinear simplex optimization, followed by a local registration using a cubic B-spline method with fast localized optimization. The corresponding coronary arteries among the available phases are identified using a recursive coronary segment matching method. Each of the identified vessel segments is transformed by the curved planar reformation (CPR) method. Four features are extracted from each corresponding segment as quality indicators in the original computed tomography volume and the straightened CPR volume, and each quality indicator is used as a voting classifier for the arterial segment. A weighted voting ensemble (WVE) classifier is designed to combine the votes of the four voting classifiers for each corresponding segment. The segment with the highest WVE vote is then selected as the best-quality segment. In this study, the training and test sets consisted of 6 and 20 cCTA cases, respectively, each with 6 phases, containing a total of 156 cCTA volumes and 312 coronary artery trees. An observer preference study was also conducted with one expert cardiothoracic radiologist and four nonradiologist readers to visually rank vessel segment

  13. Coronary artery analysis: Computer-assisted selection of best-quality segments in multiple-phase coronary CT angiography

    International Nuclear Information System (INIS)

    Zhou, Chuan; Chan, Heang-Ping; Hadjiyski, Lubomir M.; Chughtai, Aamer; Wei, Jun; Kazerooni, Ella A.

    2016-01-01

    Purpose: The authors are developing an automated method to identify the best-quality coronary arterial segment from multiple-phase coronary CT angiography (cCTA) acquisitions, which may be used by either interpreting physicians or computer-aided detection systems to optimally and efficiently utilize the diagnostic information available in multiple-phase cCTA for the detection of coronary artery disease. Methods: After initialization with a manually identified seed point, each coronary artery tree is automatically extracted from multiple cCTA phases using our multiscale coronary artery response enhancement and 3D rolling balloon region growing vessel segmentation and tracking method. The coronary artery trees from multiple phases are then aligned by a global registration using an affine transformation with quadratic terms and nonlinear simplex optimization, followed by a local registration using a cubic B-spline method with fast localized optimization. The corresponding coronary arteries among the available phases are identified using a recursive coronary segment matching method. Each of the identified vessel segments is transformed by the curved planar reformation (CPR) method. Four features are extracted from each corresponding segment as quality indicators in the original computed tomography volume and the straightened CPR volume, and each quality indicator is used as a voting classifier for the arterial segment. A weighted voting ensemble (WVE) classifier is designed to combine the votes of the four voting classifiers for each corresponding segment. The segment with the highest WVE vote is then selected as the best-quality segment. In this study, the training and test sets consisted of 6 and 20 cCTA cases, respectively, each with 6 phases, containing a total of 156 cCTA volumes and 312 coronary artery trees. An observer preference study was also conducted with one expert cardiothoracic radiologist and four nonradiologist readers to visually rank vessel segment

  14. Coronary ostium occlusion by coronary cusp displacement in Williams syndrome.

    Science.gov (United States)

    Shiohama, Tadashi; Fujii, Katsunori; Ebata, Ryota; Funabashi, Nobusada; Matsumiya, Goro; Saito, Yuko Kazato; Takechi, Fumie; Yonemori, Yoko; Nakatani, Yukio; Shimojo, Naoki

    2016-06-01

    Williams syndrome is a contiguous gene deletion syndrome resulting from a heterozygous deletion on chromosome 7q11.23, and is characterized by distinctive facial features and supravalvular aortic stenosis (SVAS). This syndrome rarely presents unpredictable cardiac death, and yet, as illustrated in the present case, it is still not possible to predict it, even on close monitoring. We herein describe the case of a 6-year-old Japanese girl with Williams syndrome, who had sudden cardiac collapse due to cardiac infarction after pharyngitis. Cardiac failure followed a critical course that did not respond to catecholamine support or heart rest with extracardiac mechanical support. Although marked coronary stenosis was not present, the left coronary cusp abnormally adhered to the aortic wall, which may synergistically cause coronary ostium occlusion with SVAS. Altered hemodynamic state, even that caused by the common cold, may lead to critical myocardial events in Williams syndrome with SVAS. © 2015 Japan Pediatric Society.

  15. NEUROTICISM PROFILE IN CORONARY HEART DISEASE

    OpenAIRE

    Bhargava, S. C.; Sharma, S. N.; Agarwal, B. V.

    1980-01-01

    SUMMARY Thirty seven cases of coronary heart disease and 30 normal healthy controls were administered Hindi version of MHQ. The coronary heart disease patients scored significantly higher on total neuroticism, free-floating anxiety and somatic anxiety subscales of MHQ.

  16. Non invasive cardiac vein mapping: Role of multislice CT coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Malago, Roberto, E-mail: robertomalag@yahoo.it [Radiology Department, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy); Pezzato, Andrea; Barbiani, Camilla; Sala, Giuseppe; Zamboni, Giulia A. [Radiology Department, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy); Tavella, Domenico [Cardiology Service, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy); Mucelli, Roberto Pozzi [Radiology Department, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy)

    2012-11-15

    Purpose: Coronary venous anatomy is of primary importance when implanting a cardiac resynchronization therapy device, besides, the coronary sinus can be differently enlarged depending on chronic heart failure. The aim of this study is to evaluate the usefulness of Coronary CTA in describing the coronary venous tree and in particular the coronary sinus and detecting main venous system variants. Materials and methods: 301 consecutive patients (196 Male-Sign , mean age 63.74 years) studied for coronary artery disease with 64 slice Coronary CTA were retrospectively examined. The acquisition protocol was the standard acquisition one used for coronary artery evaluation but the cardiac venous system were visualized. The cardiac venous system was depicted using 3D, MPR, cMPR and MIP post-processing reconstructions on an off-line workstation. For each patient image quality, presence and caliber of the coronary sinus (CS), great cardiac vein (GCV), middle vein (MV), anterior interventricular vein (AIV), lateral cardiac vein (LCV), posterior cardiac vein (PCV), small cardiac vein (SCV) and presence of variant of the normal anatomy were examined and recorded. Results: CS, GCV, MV and AIV were visualized in 100% of the cases. The LCV was visualized in 255/301 (84%) patients, the PCV in 248/301 (83%) patients and the SCV in 69/301 (23%) patients. Mean diameter of the CS was 8.7 mm in 276/301 (91.7%) patients without chronic heart failure and 9.93 mm in 25/301 (8.3%) patients with chronic heart failure. Conclusions: Coronary CTA allows non invasive mapping of the cardiac venous system and may represent a useful presurgical tool for biventricular pacemaker devices implantation.

  17. Coronary spasm induced by dipyridamole

    International Nuclear Information System (INIS)

    Wartski, M.; Caussin, C.; Lancelin, B.

    2001-01-01

    A 59 years old man was admitted at hospital for recurrent instable angina 1 month after coronary artery bypass surgery. Coronary artery disease started with a transmural antero-septo-apical myocardial infarction without thrombolysis and a percutaneous angioplasty with endo-prothesis on proximal left anterior descendant artery (LAD) is performed Because of recurrent rest angina and subacute stent thrombosis, a coronary artery bypass surgery (CABG) is performed with anastomosis of the left internal thoracic artery on LAD. The patient is admitted for recurrent rest angina one month after CABG. On ECG performed during chest pain, a ST-T segment elevation occurred on inferior leads. Coronary angiography showed no significant stenosis on endo-prothesis and no bypass graft dysfunction. Dipyridamole scintigraphy was realized. 2 minutes after the beginning of Dipyridamole infusion, a ST-T elevation occurred on inferior leads and two marked antero-septal and inferior defects were noticed on myocardial scintigraphy. Images at rest showed a clear improvement in the anterior wall and the inferior wall became normally perfused Patient was treated with anti-spastic drugs and a new coronarography with methyl-ergotamine test was performed inducing chest pain, ST-T elevation on inferior leads and tri-truncular coronary spasm. Patient's treatment was then modified with introduction of Nifedipine. The patient did not experienced new recurrent chest pain and remained totally asymptomatic few months later. (authors)

  18. Myocardial perfusion studies in coronary diseases; Estudios de Perfusion Miocardica en la Enfermedad Coronaria

    Energy Technology Data Exchange (ETDEWEB)

    Mut, Fernando [Universidad de la Republica, Montevideo (Uruguay)

    1994-12-31

    For detecting in precocious form a coronary disease is necessary to apply a diagnostic techniques. The main considerations to be indicated in the present work are: physiological considerations, myocardial perfusion studies with radiotracers such as Talio 201, 99mTc, MIBI, 99mTc-Teboroxima, 99mTc-Fosfinas, instrumentation for obtain good images,proceedings protocols, studies interpretation, standards, SPECT, anomalies standards, coronary diseases.

  19. Advantages in diagnosis of coronary artery disease by a combination of nuclear medicine methods

    International Nuclear Information System (INIS)

    Schmidt, H.A.E.; Birk, W.; Michele, E.

    1983-01-01

    Investigations on 106 patients with coronary artery disease were performed to improve the diagnosis of myocardial ischemia by combining myocardial scintigraphy and gated blood pool studies. The results show that it is possible to enhance the detection of coronary artery and to classify haemodynamic efficiency. In addition we found that in investigations performed on patients with arrhytmia and under stress conditions the 'hybrid-technique' is superior to the framemode acquisition method. (orig.) [de

  20. High coronary calcium score and post-procedural CK-MB are noninvasive predictors of coronary stent restenosis

    Directory of Open Access Journals (Sweden)

    Lee JB

    2017-02-01

    Full Text Available Jae-Beom Lee,1 Yun-Seok Choi,2 Woo-Baek Chung,2 Ami Kwon,2 Chul-Soo Park,2 Man-Young Lee2 1Anyang Sam Hospital, 2Division of Cardiology, Department of Internal Medicine, Youido St Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea Purpose: High coronary calcium score (CCS and post-procedural cardiac enzyme may be related with poor outcomes in patients with coronary stent implantation. Methods: A total of 1,072 patients (63.2% male, mean age: 61.7±10.3 years who underwent coronary multi-detect computed tomography at index procedure and follow-up coronary angiography (CAG after drug-eluting stent (DES were divided into two groups: those with and without target lesion revascularization (TLR; >50% reduction in luminal stent diameter or angina symptoms on follow-up CAG. The CCSs for predicting stent revascularization were elucidated. Results: There were no significant differences between the two groups with regard to risk factors. The initial CCS was significantly higher in the TLR group (1,102.4±743.7 vs 345.8±51.05, P=0.04. After adjustment of significant factors for TLR, only CCS and post-procedural creatine kinase MB form (CK-MB elevation were significant predictors of coronary artery TLR. Receiver operation curve revealed that >800 in CCS had 69% in sensitivity and 88% in specificity about predicting the TLR. Conclusion: High CCS with post-procedural CK-MB might be the useful predictors for TLR after DES implantation. Keywords: coronary restenosis, drug-eluting stents, calcium, creatine kinase

  1. Visibility of the origin and proximal course of coronary arteries on non-ECG-gated heart CT in patients with congenital heart disease

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Park, In-Sook; Ko, Jae Kon; Kim, Young Hwee; Seo, Dong-Man; Yun, Tae-Jin; Park, Jeong-Jun

    2005-01-01

    There is little information on the ability of non-ECG-gated cardiac CT to demonstrate the coronary arteries of children. To evaluate the visibility of the origin and proximal course of coronary arteries on non-ECG-gated cardiac CT, in which the coronary artery was not of primary diagnostic concern, in children with congenital heart disease. From December 2002 to March 2004, 126 cardiac CT examinations from 104 children (median age 11 months; age range 1 day to 15 years) were evaluated. All patients had ventriculo-arterial concordance and no malformations of the great arteries; those with coronary artery anomalies were excluded. Contrast-enhanced 16-slice spiral CT was performed without ECG-gating and multiplanar images for coronary arteries were obtained. The visibility of coronary artery origins was graded on a three-point scale, while nine segments of the arteries were graded on a four-point scale. CT images in which it was possible to trace the coronary arteries were considered diagnostic. The visibility of each whole coronary artery and the origins and proximal four segments of coronary arteries were calculated. The visibility of coronary arteries was also correlated with patient age. The percentage of CT images of diagnostic quality was 49.3% for the whole coronary artery and 81.7% for the origins and proximal four segments. There was a significant positive correlation between the visibility of coronary arteries and age. Non-ECG-gated cardiac CT, in which the coronary artery is not of primary diagnostic concern, is frequently able to visualize the origin and proximal course of coronary arteries and may be helpful in detecting coronary artery anomalies in children with congenital heart disease. (orig.)

  2. HUMAN CORONARY ARTERIES- A STUDY BASED ON GROSS ANATOMY AND CORONARY CAST

    Directory of Open Access Journals (Sweden)

    Vijayamma K. N

    2018-01-01

    Full Text Available BACKGROUND Present study is an attempt to throw light upon the coronary arterial pattern, variations in arterial distribution and extent of intercoronary anastomosis and arterial preponderance in different age groups. MATERIALS AND METHODS Total of 115 hearts were made use for this study. Ninety hearts were dissected for the gross anatomical study of coronary arteries and 25 hearts including three fetal hearts were used for the coronary cast study. The right and left coronary arteries were traced from aortic sinus along the atrioventricular groove to the area of its termination. The atrial ventricular and septal branches were traced and looked for anastomosis. Coronary casts were prepared by injecting coloured liquid latex through the coronary ostia and the branching pattern and anastomosis were studied. The coronary arterial pattern, extent of distribution of its branches, arterial preponderance and variations were observed. RESULTS It was found that 73 % cases of SA nodal branch arise from right coronary artery and 27 % from circumflex branch of left coronary artery. SA node has dual blood supply from both coronary arteries in 4% cases. Right coronary preponderance was observed in 83% of cases and left coronary preponderance in 11 % cases, and balanced supply in 6% cases. Coronary cast was helpful to understand the branching pattern of vessels, and the anastomosis of small capillaries. It was also seen that all 11 % of left preponderance were seen in male hearts and all of the 31 female hearts dissected were right preponderant. CONCLUSION Coronary arteries are called end arteries functionally. Right coronary artery originates from anterior aortic sinus in all cases except one which takes origin from posterior left aortic sinus along with left coronary artery. Right coronary preponderance is observed in 83% cases. Left coronary artery branching pattern shows variability. Left coronary preponderance was observed in 11% and all cases are male

  3. Progress in genetics of coronary artery disease

    African Journals Online (AJOL)

    Radwa Gamal

    To the Editor. Coronary Heart Disease (CHD) is the leading cause of mortality and morbidity worldwide [1] and it is a result of coronary artery disease (CAD). Coronary artery disease refers to the build-up of atherosclerotic plaque in the blood vessels that supply oxygen and nutrients to the heart. Progressive infiltration of the ...

  4. Coronary CT in Acute Cardiac Care

    NARCIS (Netherlands)

    A. Dedic (Admir)

    2016-01-01

    markdownabstractCoronary CT angiography is a well-established diagnostic modality for stable angina pectoris. It provides an angiographic, non-invasive alternative for the diagnosis of coronary artery disease, exceeding in the ability to exclude important coronary artery disease. Having the ability

  5. Italian Chapter of the International Society of Cardiovascular Ultrasound expert consensus document on coronary computed tomography angiography: overview and new insights.

    Science.gov (United States)

    Sozzi, Fabiola B; Maiello, Maria; Pelliccia, Francesco; Parato, Vito Maurizio; Canetta, Ciro; Savino, Ketty; Lombardi, Federico; Palmiero, Pasquale

    2016-09-01

    Coronary computed tomography angiography is a noninvasive heart imaging test currently undergoing rapid development and advancement. The high resolution of the three-dimensional pictures of the moving heart and great vessels is performed during a coronary computed tomography to identify coronary artery disease and classify patient risk for atherosclerotic cardiovascular disease. The technique provides useful information about the coronary tree and atherosclerotic plaques beyond simple luminal narrowing and plaque type defined by calcium content. This application will improve image-guided prevention, medical therapy, and coronary interventions. The ability to interpret coronary computed tomography images is of utmost importance as we develop personalized medical care to enable therapeutic interventions stratified on the bases of plaque characteristics. This overview provides available data and expert's recommendations in the utilization of coronary computed tomography findings. We focus on the use of coronary computed tomography to detect coronary artery disease and stratify patients at risk, illustrating the implications of this test on patient management. We describe its diagnostic power in identifying patients at higher risk to develop acute coronary syndrome and its prognostic significance. Finally, we highlight the features of the vulnerable plaques imaged by coronary computed tomography angiography. © 2016, Wiley Periodicals, Inc.

  6. Diagnostic accuracy of prospective ECG gated coronary computed tomography on a 256 slices scanner: Daily practice experience

    Directory of Open Access Journals (Sweden)

    Ahmed M. Fareed

    2014-03-01

    Conclusions: In a highly prevalence diseased population, prospective ECG-gated CTCA using 256-slice scanner is highly accurate for detection and quantification of the degree of coronary luminal stenosis in comparison to ICA.

  7. Coronary Artery Bypass in Octogenarians

    Directory of Open Access Journals (Sweden)

    Chen-Yen Chien

    2012-09-01

    Full Text Available Prevalence of coronary artery disease (CAD has increased with the expansion of life span among the elderly population in the world. Hence, the issue of the coronary artery bypass in octogenarians has attracted more attention. Recent literature about the topic revealed nearly the same excellent results as those in the younger population under the newly developed operative techniques and improving concept in perioperative management and postoperative care. In this article, we review the current status of the procedure that was thought to be dangerous in the earlier era, including its risk factors, result, and benefit.

  8. Homocysteine and coronary heart disease

    DEFF Research Database (Denmark)

    Clarke, Robert; Bennett, Derrick A; Parish, Sarah

    2012-01-01

    Moderately elevated blood levels of homocysteine are weakly correlated with coronary heart disease (CHD) risk, but causality remains uncertain. When folate levels are low, the TT genotype of the common C677T polymorphism (rs1801133) of the methylene tetrahydrofolate reductase gene (MTHFR) appreci......Moderately elevated blood levels of homocysteine are weakly correlated with coronary heart disease (CHD) risk, but causality remains uncertain. When folate levels are low, the TT genotype of the common C677T polymorphism (rs1801133) of the methylene tetrahydrofolate reductase gene (MTHFR...

  9. Myocardial ischemia in severe aortic regurgitation despite angiographically normal coronary arteries

    International Nuclear Information System (INIS)

    Aksoy, S.; Cam, N.; Guney, M.R.; Gurkan, U.; Oz, D.; Poyraz, E.; Eksik, A.; Agirbasli, M.

    2012-01-01

    Patients with severe aortic regurgitation frequently present with angina pectoris. The exact pathophysiology for angina in aortic regurgitation is not clear. Left ventricular hypertrophy and myocardial blood supply-demand mismatch have been the suggested mechanisms to explain ischemia. However, no conclusive clinical study exists to define the incidence of ischemia in patients with severe aortic regurgitation and normal coronary arteries. We, therefore, investigated the frequency of myocardial ischemia in relation to left ventricular hypertrophy or dilatation in patients with severe aortic regurgitation and normal coronary arteries. We reviewed the medical records of all patients (n=311) with aortic valve replacement due to aortic regurgitation between 2007 and 2010. We selected subjects with normal coronary arteries (n=182) for the study purpose, and we identified 35 patients who underwent myocardial perfusion scintigraphy prior to the coronary angiography (19 female and 16 male subjects; age 45.0±8.9 years). Left ventricular hypertrophy and dilatation were detected in 9 (26%) and 5 (14%) patients, respectively. Myocardial perfusion scintigraphy showed evidence of ischemia in 10 (29%) patients with normal coronary arteries. The presence of ischemia did not relate to the presence of left ventricular hypertrophy and/or dilatation. As a potential mechanism, aortic regurgitation causes backflow of blood from the aorta into the left ventricle, hence disturbs coronary flow dynamics. In conclusion, myocardial ischemia is common (nearly one-third) among patients with severe aortic regurgitation even in the absence of coronary obstruction, left ventricular hypertrophy and/or dilatation. (author)

  10. Assessment of coronary arteries in infants by 64-detector-row multislice spiral computed tomography

    International Nuclear Information System (INIS)

    Tahara, Masahiro; Waki, Chiaki; Komatsu, Hiroaki; Hayashi, Tomohiro; Sato, Tomoyasu

    2008-01-01

    Heart rate is one of the most important factors for optimal visualization of cardiac CT. We investigated the relation between heart rate and visibility of the coronary arteries with 64-detector row multislice spiral computed tomography (MSCT). Three simulated coronary artery stenosis models (3, 4, and 5 mm) were attached to a moving heart phantom and scanned using 64-detector row MSCT. The heart rate of the phantom was varied between 60 and 150 beats per minutes (bpm). The visibility of simulated coronary arteries was assessed in comparison between cardiac half reconstruction (CHR) and multi-sector reconstruction (MSR). Then contrast-enhanced 64-detector row MSCT was performed in 16 patients under 3 years of age with congenital heart disease and Kawasaki disease without heart rate control. The visibility of coronary artery segments was graded on a three-point scale. The simulated coronary artery patency was detected in the moving phantom at maximum heart rate (150 bpm) with MSR. Minimum lumen diameter was 0.75 mm. Electrocardiogram (ECG)-gated cardiac CT was performed in 9 patients, and non-ECG-gated cardiac CT was performed in 7 patients. The origin and proximal course of coronary arteries in all 9 patients with ECG-gated acquisition were visually evaluated. 64-detector row MSCT with ECG-gated acquisition is able to visualize the origin and proximal course of coronary arteries in infants under 3 years of age. (author)

  11. Feasibility and diagnostic power of transthoracic coronary Doppler for coronary flow velocity reserve in patients referred for myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Nylander Eva

    2008-03-01

    Full Text Available Abstract Background Myocardial perfusion imaging (MPI, using single photon emission computed tomography (SPECT is a validated method for detecting coronary artery disease. Transthoracic Doppler echocardiography (TTDE of flow at rest and during adenosine provocation has previously been evaluated in selected patient groups. We therefore wanted to compare the diagnostic ability of TTDE in the left anterior descending coronary artery (LAD to that of MPI in an unselected population of patients with chest pain referred for MPI. Our hypothesis was that TTDE with high accuracy would identify healthy individuals and exclude them from the need for further studies, enabling invasive investigations to be reserved for patients with a high probability of disease. Methods Sixty-nine patients, 44 men and 25 women, age 61 ± 10 years (range 35–82, with a clinical suspicion of stress induced myocardial ischemia, were investigated. TTDE was performed at rest and during adenosine stress for myocardial scintigraphy. Results We found that coronary flow velocity reserve (CFVR determined from diastolic measurements separated normal from abnormal MPI findings with statistical significance. TTDE identified coronary artery disease, defined from MPI, as reversible ischemia and/or permanent defect, with a sensitivity of 60% and a specificity of 79%. The positive predictive value was 43% and the negative predictive value was 88%. There was an overlap between groups which could be due to abnormal endothelial function in patients with normal myocardial perfusion having either hypertension or diabetes. Conclusion TTDE is an attractive non-invasive method to evaluate chest pain without the use of isotopes, but the diagnostic power is strongly dependent on the population investigated. Even in our heterogeneous clinical cardiac population, we found that CFVR>2 in the LAD excluded significant coronary artery disease detected by MPI.

  12. Coronary microvasculopathy in heart transplantation: Consequences and therapeutic implications.

    Science.gov (United States)

    Vecchiati, Alessandra; Tellatin, Sara; Angelini, Annalisa; Iliceto, Sabino; Tona, Francesco

    2014-06-24

    Despite the progress made in the prevention and treatment of rejection of the transplanted heart, cardiac allograft vasculopathy (CAV) remains the main cause of death in late survival transplanted patients. CAV consists of a progressive diffuse intimal hyperplasia and the proliferation of vascular smooth muscle cells, ending in wall thickening of epicardial vessels, intramyocardial arteries (50-20 μm), arterioles (20-10 μm), and capillaries (system. The non-immunological factors are older donor age, ischemia-reperfusion time, hyperlipidemia and CMV infections. Diagnostic techniques that are able to assess microvascular function are lacking. Intravascular ultrasound and fractional flow reserve, when performed during coronary angiography, are able to detect epicardial coronary artery disease but are not sensitive enough to assess microvascular changes. Some authors have proposed an index of microcirculatory resistance during maximal hyperemia, which is calculated by dividing pressure by flow (distal pressure multiplied by the hyperemic mean transit time). Non-invasive methods to assess coronary physiology are stress echocardiography, coronary flow reserve by transthoracic Doppler echocardiography, single photon emission computed tomography, and perfusion cardiac magnetic resonance. In this review, we intend to analyze the mechanisms, consequences and therapeutic implications of microvascular dysfunction, including an extended citation of relevant literature data.

  13. A comparison of hybrid coronary revascularization and off-pump coronary revascularization.

    Science.gov (United States)

    Umakanthan, Ramanan; Leacche, Marzia; Gallion, Anna H; Byrne, John G

    2013-04-01

    Minimally invasive approaches to treat vascular disease have been accruing significant popularity over the last several decades. Due to progressive advances in technology, a variety of techniques are being now utilized in the field of cardiovascular surgery. The objectives of minimally invasive techniques are to curtail operative trauma and minimize perioperative morbidity without decreasing the quality of the treatment. The standard surgical approach for the treatment of coronary artery disease has traditionally been coronary artery bypass grafting surgery via median sternotomy. Off-pump coronary artery bypass grafting surgery offers a less invasive alternative and enables coronary revascularization to be performed without cardiopulmonary bypass. Hybrid coronary revascularization offers an even less invasive option in which minimally invasive direct coronary artery bypass can be combined with percutaneous coronary intervention. In this article, the authors review a recent publication comparing hybrid coronary revascularization and off-pump coronary artery bypass grafting surgery.

  14. Combined anatomical and functional imaging using coronary CT angiography and myocardial perfusion SPECT in symptomatic adults with abnormal origin of a coronary artery.

    Science.gov (United States)

    Uebleis, C; Groebner, M; von Ziegler, F; Becker, A; Rischpler, C; Tegtmeyer, R; Becker, C; Lehner, S; Haug, A R; Cumming, P; Bartenstein, P; Franz, W M; Hacker, M

    2012-10-01

    There has been a lack of standardized workup guidelines for patients with congenital abnormal origin of a coronary artery from the opposite sinus (ACAOS). We aimed to evaluate the use of cardiac hybrid imaging using multi-detector row CT (MDCT) for coronary CT angiography (Coronary CTA) and stress-rest myocardial perfusion SPECT (MPS) for comprehensive diagnosis of symptomatic adult patients with ACAOS. Seventeen symptomatic patients (12 men; 54 ± 13 years) presenting with ACAOS underwent coronary CTA and MPS. Imaging data were analyzed by conventional means, and with additional use of 3D image fusion to allocate stress induced perfusion defects (PD) to their supplying coronary arteries. An anomalous RCA arose from the left anterior sinus in eight patients, an abnormal origin from the right sinus was detected in nine patients (5 left coronary arteries, LCA and 4 LCx). Five of the 17 patients (29%) demonstrated a reversible PD in MPS. There was no correlation between the anatomical variants of ACAOS and the presence of myocardial ischemia. Image fusion enabled the allocation of reversible PD to the anomalous vessel in three patients (two cases in the RCA and the other in the LCA territory); PD in two patients were allocated to the territory of artery giving rise to the anomalies, rather than the anomalies themselves. In a small cohort of adult symptomatic patients with ACAOS anomaly there was no relation found between the specific anatomical variant and the appearance of stress induced myocardial ischemia using cardiac hybrid imaging.

  15. Coronary Heart Disease and Exercises

    Directory of Open Access Journals (Sweden)

    Tolga SAKA

    2016-06-01

    Full Text Available Coronary heart disease is a chronic process, of which the progression can rapidly change the functional capacity of patients. In CAD patients, the quality of life can be improved with an appropriate exercise prescription. This article explains how a safe exercise program for CAD patients can be prescribed.

  16. Diagnostic accuracy of dual-source CT coronary angiography in a population unselected for degree of coronary artery calcification and without heart rate modification

    International Nuclear Information System (INIS)

    Lin, C.-J.; Hsu, J.-C.; Lai, Y.-J.; Wang, K.-L.; Lee, J.-Y.; Li, A.-H.; Chu, S.-H.

    2010-01-01

    Aim: To assess the ability of coronary angiography performed using dual-source computed tomography (DSCT) to evaluate coronary artery disease (CAD) in a population with unselected heart rates and extensive coronary calcification. Materials and methods: Forty-four patients at intermediate to high risk for CAD underwent both DSCT coronary angiography and invasive coronary angiography (ICA) within 30 days. No beta blockers were administered prior to imaging. Image quality and quantitatively stenosis of all coronary segments with a diameter ≥1.5 mm were accessed. Patients were stratified according to mean heart rate (<70 versus ≥70 bpm) and heart rate variability (<10 versus ≥10 bpm). DSCT detection of coronary stenosis by segment, vessel, and patient characteristics were compared to the reference standard of ICA. Results: Diagnostic accuracy for all patients was high regarding sensitivity (97%), positive predictive value (PPV, 84.2%), and negative predictive value (NPV, 83.3%) but low regarding specificity (45.5%) with a moderate interobserver agreement (Kappa = 0.50). The accuracy for vessel-based diagnosis was high regarding sensitivity (96.6%), specificity (80.8%), PPV (80.3%), and NPV (96.7%). The segment-based diagnostic results revealed a moderate interobserver agreement for image quality and sensitivity, specificity, PPV and NPV for all segments of 66.9, 97.8, 90.8, and 89.9%, respectively. Conclusion: DSCT coronary angiography has high diagnostic accuracy in assessing CAD among patients at intermediate to high risk without using heart rate-modulating premedication. DSCT is not superior to ICA for diagnosis of calcified segments.

  17. Assessment of coronary artery disease by post-mortem cardiac MR

    International Nuclear Information System (INIS)

    Ruder, Thomas D.; Bauer-Kreutz, Regula; Ampanozi, Garyfalia; Rosskopf, Andrea B.; Pilgrim, Thomas M.; Weber, Oliver M.; Thali, Michael J.; Hatch, Gary M.

    2012-01-01

    Objectives: Minimally invasive or virtual autopsies are being advocated as alternative to traditional autopsy, but have limited abilities to detect coronary artery disease. It was the objective of this study to assess if the occurrence of chemical shift artifacts (CSA) along the coronary arteries on non-contrast, post-mortem cardiac MR may be used to investigate coronary artery disease. Methods: We retrospectively compared autopsy and CT findings of 30 cases with significant (≥75%), insignificant (<75%), or absent coronary artery stenosis to post-mortem cardiac MR findings. The chi-square test was used to investigate if the occurrence of CSA depends on the presence or absence of stenosis. Sensitivity, specificity and predictive values were calculated for each finding. Results: CSA indicates the absence of (significant) stenosis (p < 0.001). The occurrence of paired dark bands in lieu of CSA on post-mortem cardiac MR suggests (significant) coronary arteries stenosis (p < 0.001). Both findings have a high specificity but low sensitivity. Conclusions: CSA is a marker of vessel patency. The presence of paired dark bands indicates stenosis. These criteria improve the ability of minimally invasive or virtual autopsy to detect coronary artery disease related deaths

  18. Novel Approaches for the Use of Cardiac/Coronary Computed Tomography Angiography

    Directory of Open Access Journals (Sweden)

    Hadi Mirhedayati Roudsari, MD

    2016-12-01

    Full Text Available Recent developments in the novel imaging technology of cardiac computed tomography (CT not only permit detailed assessment of cardiac anatomy but also provide insight into cardiovascular physiology. Foremost, coronary CT angiography (CCTA enables direct noninvasive examination of both coronary artery stenoses and atherosclerotic plaque characteristics. Calculation of computational fluid dynamics by cardiac CT allows the noninvasive estimation of fractional flow reserve, which increases the diagnostic accuracy for detection of hemodynamically significant coronary artery disease. In addition, a combination of myocardial CT perfusion and CCTA can provide simultaneous anatomical and functional assessment of coronary artery disease. Finally, detailed anatomical evaluation of atrial, ventricular, and valvular anatomy provides diagnostic information and guidance for procedural planning, such as for transcatheter aortic valve replacement. The clinical applications of cardiac CT will be extended with the development of these novel modalities.

  19. Macroscopic description of the coronary arteries in Swiss albino mice (Mus musculus

    Directory of Open Access Journals (Sweden)

    A. Yoldas

    2010-05-01

    Full Text Available A total of 25 (13 male, 12 female adult, healthy Swiss albino mice were used to investigate the origin, course and anastomoses of coronary arteries. Coloured latex was injected into the aortic arch to enable these arteries to be clearly discerned. A. coronaria sinistra was larger than A. coronaria dextra. It was divided into a Ramus interventricularis paraconalis and a Ramus circumflexus sinister. However, in 2 specimens, the septal ramus, was observed to stem directly from the left coronary artery, and only 1 ventricular branch arose from the left circumflex. The collateral branches of the paraconal interventricular ramus had a larger diameter and more extensive distribution was observed in these specimens. The A. coronaria dextra was divided into a Ramus septalis and Ramus circumflexus dexter. The Ramus interventricularis subsinuosis was not detected in this study. The ventricular branches of the left coronary artery run intramyocardially whereas the branches of the right coronary artery course subendocardially.

  20. Plaque disruption by coronary computed tomographic angiography in stable patients vs. acute coronary syndrome: a feasibility study.

    Science.gov (United States)

    Bilolikar, Abhay N; Goldstein, James A; Madder, Ryan D; Chinnaiyan, Kavitha M

    2016-03-01

    This study was designed to determine whether coronary CT angiography (CTA) can detect features of plaque disruption in clinically stable patients and to compare lesion prevalence and features between stable patients and those with acute coronary syndrome (ACS). We retrospectively identified patients undergoing CTA, followed by invasive coronary angiography (ICA) within 60 days. Quantitative 3-vessel CTA lesion analysis was performed on all plaques ≥25% stenosis to assess total plaque volume, low attenuation plaque (LAP, disruption, including ulceration and intra-plaque dye penetration (IDP). ICA was employed as a reference standard for disruption. A total of 145 (94 ACS and 51 stable) patients were identified. By CTA, plaque disruption was evident in 77.7% of ACS cases. Although more common among those with ACS, CTA also detected plaque disruption in 37.3% of clinically stable patients (P disruption as determined by CTA. Though the prevalence of plaque disruption is less than patients with ACS, these findings support the concept that some clinically stable patients may harbour 'silent' disrupted plaques. These findings may have implications for detection of 'at risk' plaques and patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  1. Coronary Anomaly and Coronary Artery Fistula as Cause of Angina Pectoris with Literature Review

    Directory of Open Access Journals (Sweden)

    Jayanth Koneru

    2011-01-01

    Full Text Available Coronary artery fistulas are rare anomalies of the coronary arteries that may sometimes cause symptoms by shunting blood flow away from the myocardial capillary network. We report the case of a 46-year old lady which shows the right coronary cusp giving rise to left main coronary artery called anomalous origin of a coronary artery (AOCA, and also a fistula between the left coronary artery and pulmonary artery. We describe our diagnostic approach and review the literature on the epidemiology, pathophysiology, the diagnostic modalities, and treatment options.

  2. Influence of psychological and coronary parameters on coronary patient rehospitalization

    Directory of Open Access Journals (Sweden)

    Nikolić Gordana

    2010-01-01

    Full Text Available Introduction. Psychological reactions are often comorbid with coronary risk factors and could be important for a six-month outcome. Objective. Determination of anxiety level, depression and aggression, persistence of risk health behaviour, stress life events, and coronary risk factors after coronary event and a predictive value of those parameters for six-month rehospitalization. Methods. In the group with Angina Pectoris (E1=30 and the group with Acute Myocardial Infarction (E2=33, there were applied, at baseline and after 6 months, the following: Semistructured Clinical Interview based on ICD-10, for depressive episode and anxiety disorder, Hamilton Anxiety Scale (HAMA, Hamilton Depression Scale (HAMD, KON-6 sigma Scale for aggression, Holms-Rahe Scale (H-R for stress events and Questionnaire for risk behaviour: alcohol consumption, smoking, lack of physical activity. Group differences were assessed by t-test and chi-square test, p<0.05, regression analysis for assessing initial variables, a predictive value for six month rehospitalization. Results. After acute coronary event, the anxiety and depression levels were mild and aggression was low in E1 and mild in E2. Stress event score was significantly higher in E2 (H-R=115.18 than in E1 (H-R=72.20, p<0.05. After 6 months, the results were the same except for a significantly lower stress event score in E1 (H-R=49.48, and in E2 (H-R=91.65, but still significantly higher than in E1. Coronary parameters were reduced, smokers' rate was increased in E1. Alcohol consumption, hypercholesterolaemia and hereditary tendency were predictive for six- month rehospitalization. Conclusion. After acute cardiac event, hospitalized coronary patients had a mild anxiety, depression and aggression level as well as after six months. The infarct patients had experienced more stress life events in the previous year than the angina patients. Risk health behaviour did not change in the following six months, with the

  3. Non-invasive prediction of hemodynamically significant coronary artery stenoses by contrast density difference in coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Hell, Michaela M., E-mail: michaela.hell@uk-erlangen.de [Department of Cardiology, University of Erlangen (Germany); Dey, Damini [Department of Biomedical Sciences, Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Taper Building, Room A238, 8700 Beverly Boulevard, Los Angeles, CA 90048 (United States); Marwan, Mohamed; Achenbach, Stephan; Schmid, Jasmin; Schuhbaeck, Annika [Department of Cardiology, University of Erlangen (Germany)

    2015-08-15

    Highlights: • Overestimation of coronary lesions by coronary computed tomography angiography and subsequent unnecessary invasive coronary angiography and revascularization is a concern. • Differences in plaque characteristics and contrast density difference between hemodynamically significant and non-significant stenoses, as defined by invasive fractional flow reserve, were assessed. • At a threshold of ≥24%, contrast density difference predicted hemodynamically significant lesions with a specificity of 75%, sensitivity of 33%, PPV of 35% and NPV of 73%. • The determination of contrast density difference required less time than transluminal attenuation gradient measurement. - Abstract: Objectives: Coronary computed tomography angiography (CTA) allows the detection of obstructive coronary artery disease. However, its ability to predict the hemodynamic significance of stenoses is limited. We assessed differences in plaque characteristics and contrast density difference between hemodynamically significant and non-significant stenoses, as defined by invasive fractional flow reserve (FFR). Methods: Lesion characteristics of 59 consecutive patients (72 lesions) in whom invasive FFR was performed in at least one coronary artery with moderate to high-grade stenoses in coronary CTA were evaluated by two experienced readers. Coronary CTA data sets were acquired on a second-generation dual-source CT scanner using retrospectively ECG-gated spiral acquisition or prospectively ECG-triggered axial acquisition mode. Plaque volume and composition (non-calcified, calcified), remodeling index as well as contrast density difference (defined as the percentage decline in luminal CT attenuation/cross-sectional area over the lesion) were assessed using a semi-automatic software tool (Autoplaq). Additionally, the transluminal attenuation gradient (defined as the linear regression coefficient between intraluminal CT attenuation and length from the ostium) was determined

  4. Diagnostic value of multislice computed tomography angiography in coronary artery disease: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Jiang Wen

    2006-01-01

    Purpose: To perform a meta-analysis of the diagnostic value of multislice CT (MSCT) angiography in the detection of coronary artery disease (CAD) when compared to conventional coronary angiography. Materials and methods: A search of PubMed and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing MSCT angiography with conventional coronary angiography in the detection of CAD were included. Diagnostic value of MSCT angiography compared to coronary angiography was compared and analyzed at segment-, vessel- and patient-based assessment. Results: 47 studies (67 comparisons) met the criteria and were included in our study. Pooled overall sensitivity, specificity and 95% confidence interval for MSCT angiography in the detection of CAD were 83% (79%, 89%), 93% (91%, 96%) at segment-based analysis; 90% (87%, 94%), 87% (80%, 93%) at vessel-based analysis; and 91% (88%, 95%), 86% (81%, 92%) at patient-based analysis, respectively. Diagnostic accuracy of MSCT angiography in evaluating assessable segments was significantly improved with 64-slice scanners when compared to that with 4- and 16-slice scanners (p < 0.05). Conclusion: Our meta-analysis showed that MSCT angiography has potential diagnostic accuracy in the detection of CAD. Diagnostic performance of MSCT angiography has been significantly improved with the latest 64-slice CT, with resultant high qualitative and quantitative diagnostic accuracy. 16-slice CT was limited in spatial resolution which makes it difficult to perform quantitative assessment of coronary artery stenoses

  5. High-resolution imaging of coronary calcifications by intense low-energy fluoroscopic X-ray obtained from synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Ohtsuka, S.; Sugishita, Y.; Takeda, T.; Itai, Y.; Tada, J.; Hyodo, K.; Ando, M. [Inst. of Clinical Medicine, Univ. of Tsukuba, Ibaraki (Japan). Dept. of Cardiology

    2000-07-01

    In order to obtain an intense monochromatic low-energy X-ray from synchrotron radiation (SR) and apply it to detect coronary calcifications, the SR beam was reflected with a silicon crystal to be expanded (150 mm in height and 80 mm in width) and to be monochromatized at an energy level of 37 keV. The X-ray was intermittently irradiated to obtain dynamic imaging of 30 images/s. Images were recorded by a digital fluorography system. The low-energy X-ray from SR sharply visualized calcification of coronary arteries, while conventional X-ray could not visualize coronary calcification. The intense monochromatic low-energy X-ray from SR is sensitive, has high-resolution for imaging coronary calcification and may serve as a screening method for coronary artery disease.

  6. Use of corrosion casting techniques to evaluate coronary collateral vessels and anastomoses in hearts of canine cadavers.

    Science.gov (United States)

    Noestelthaller, Arne; Probst, Alexander; Koenig, Horst E

    2005-10-01

    To study and investigate branching patterns of the canine coronary arteries and collateral circulation by use of corrosion casting techniques. 31 hearts obtained from cadavers of clinically normal dogs of various ages and breeds and of either sex. 3-dimensional reproduction of coronary arteries was achieved by postmortem injection and perfusion with casting materials into the aortic sinus via the ascending aorta. Perfused hearts were macerated and carefully irrigated; the air-dried specimens were examined macroscopically and with a magnifying headset. Collateral arteries and inter- and intra-arterial anastomoses were successfully detected in 8 corrosion cast specimens. In total, 9 coronary collateral arteries and 3 interarterial anastomoses were found. Our finding of coronary collateral arteries in canine hearts is in agreement with recent findings in coronary flow study. On the basis of our results, vasodilation treatment to improve collateral vessel remodeling in dogs with myocardial dysfunction may be warranted.

  7. Diagnostic accuracy of 64 multislice CT angiography in the assessment of coronary in-stent restenosis: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Almutairi, Abdulrahman Marzouq D.

    2010-01-01

    Purpose: The aim of this study was to perform a meta-analysis of the diagnostic accuracy of 64-slice CT angiography for the detection of coronary in-stent restenosis in patients treated with coronary stents when compared to conventional coronary angiography. Materials and methods: A search of PUBMED/MEDLINE, ProQuest and Cochrane library databases for English literature was performed. Only studies comparing 64-slice CT angiography with conventional coronary angiography for the detection of coronary in-stent restenosis (more than 50% stenosis) were included for analysis. Sensitivity and specificity estimates pooled across studies were tested using a fixed effects model. Results: Fourteen studies met selection criteria for inclusion in the analysis. The mean value of assessable stents was 89%. Prevalence of in-stent restenosis following coronary stenting was 20% among these studies. Pooled estimates of the sensitivity and specificity of overall 64-slice CT angiography for the detection of coronary in-stent restenosis was 90% (95% CI: 86%