WorldWideScience

Sample records for detailed 2-d imaging

  1. Imaging the Alpine Fault: preliminary results from a detailed 3D-VSP experiment at the DFDP-2 drill site in Whataroa, New Zealand

    Science.gov (United States)

    Lay, Vera; Bodenburg, Sascha; Buske, Stefan; Townend, John; Kellett, Richard; Savage, Martha; Schmitt, Douglas; Constantinou, Alexis; Eccles, Jennifer; Lawton, Donald; Hall, Kevin; Bertram, Malcolm; Gorman, Andrew

    2017-04-01

    The plate-bounding Alpine Fault in New Zealand is an 850 km long transpressive continental fault zone that is late in its earthquake cycle. The Deep Fault Drilling Project (DFDP) aims to deliver insight into the geological structure of this fault zone and its evolution by drilling and sampling the Alpine Fault at depth. Previously analysed 2D reflection seismic data image the main Alpine Fault reflector at a depth of 1.5-2.2 km with a dip of approximately 48° to the southeast below the DFDP-2 borehole. Additionally, there are indications of a more complex 3D fault structure with several fault branches which have not yet been clearly imaged in detail. For that reason we acquired a 3D-VSP seismic data set at the DFDP-2 drill site in January 2016. A zero-offset VSP and a walk-away VSP survey were conducted using a Vibroseis source. Within the borehole, a permanently installed "Distributed Acoustic Fibre Optic Cable" (down to 893 m) and a 3C Sercel slimwave tool (down to 400 m) were used to record the seismic wavefield. In addition, an array of 160 three-component receivers with a spacing of 10 m perpendicular and 20 m parallel to the main strike of the Alpine Fault was set up and moved successively along the valley to record reflections from the main Alpine Fault zone over a broad depth range and to derive a detailed 3D tomographic velocity model in the hanging wall. We will show a detailed 3D velocity model derived from first-arrival traveltime tomography. Subsets of the whole data set were analysed separately to estimate the corresponding ray coverage and the reliability of the observed features in the obtained velocity model. By testing various inversion parameters and starting models, we derived a detailed near-surface velocity model that reveals the significance of the old glacial valley structures. Hence, this new 3D model improves the velocity model derived previously from a 2D seismic profile line in that area. Furthermore, processing of the dense 3C data

  2. Filters in 2D and 3D Cardiac SPECT Image Processing

    Directory of Open Access Journals (Sweden)

    Maria Lyra

    2014-01-01

    Full Text Available Nuclear cardiac imaging is a noninvasive, sensitive method providing information on cardiac structure and physiology. Single photon emission tomography (SPECT evaluates myocardial perfusion, viability, and function and is widely used in clinical routine. The quality of the tomographic image is a key for accurate diagnosis. Image filtering, a mathematical processing, compensates for loss of detail in an image while reducing image noise, and it can improve the image resolution and limit the degradation of the image. SPECT images are then reconstructed, either by filter back projection (FBP analytical technique or iteratively, by algebraic methods. The aim of this study is to review filters in cardiac 2D, 3D, and 4D SPECT applications and how these affect the image quality mirroring the diagnostic accuracy of SPECT images. Several filters, including the Hanning, Butterworth, and Parzen filters, were evaluated in combination with the two reconstruction methods as well as with a specified MatLab program. Results showed that for both 3D and 4D cardiac SPECT the Butterworth filter, for different critical frequencies and orders, produced the best results. Between the two reconstruction methods, the iterative one might be more appropriate for cardiac SPECT, since it improves lesion detectability due to the significant improvement of image contrast.

  3. 2-D Imaging of Electron Temperature in Tokamak Plasmas

    International Nuclear Information System (INIS)

    Munsat, T.; Mazzucato, E.; Park, H.; Domier, C.W.; Johnson, M.; Luhmann, N.C. Jr.; Wang, J.; Xia, Z.; Classen, I.G.J.; Donne, A.J.H.; Pol, M.J. van de

    2004-01-01

    By taking advantage of recent developments in millimeter wave imaging technology, an Electron Cyclotron Emission Imaging (ECEI) instrument, capable of simultaneously measuring 128 channels of localized electron temperature over a 2-D map in the poloidal plane, has been developed for the TEXTOR tokamak. Data from the new instrument, detailing the MHD activity associated with a sawtooth crash, is presented

  4. Contributions in compression of 3D medical images and 2D images; Contributions en compression d'images medicales 3D et d'images naturelles 2D

    Energy Technology Data Exchange (ETDEWEB)

    Gaudeau, Y

    2006-12-15

    The huge amounts of volumetric data generated by current medical imaging techniques in the context of an increasing demand for long term archiving solutions, as well as the rapid development of distant radiology make the use of compression inevitable. Indeed, if the medical community has sided until now with compression without losses, most of applications suffer from compression ratios which are too low with this kind of compression. In this context, compression with acceptable losses could be the most appropriate answer. So, we propose a new loss coding scheme based on 3D (3 dimensional) Wavelet Transform and Dead Zone Lattice Vector Quantization 3D (DZLVQ) for medical images. Our algorithm has been evaluated on several computerized tomography (CT) and magnetic resonance image volumes. The main contribution of this work is the design of a multidimensional dead zone which enables to take into account correlations between neighbouring elementary volumes. At high compression ratios, we show that it can out-perform visually and numerically the best existing methods. These promising results are confirmed on head CT by two medical patricians. The second contribution of this document assesses the effect with-loss image compression on CAD (Computer-Aided Decision) detection performance of solid lung nodules. This work on 120 significant lungs images shows that detection did not suffer until 48:1 compression and still was robust at 96:1. The last contribution consists in the complexity reduction of our compression scheme. The first allocation dedicated to 2D DZLVQ uses an exponential of the rate-distortion (R-D) functions. The second allocation for 2D and 3D medical images is based on block statistical model to estimate the R-D curves. These R-D models are based on the joint distribution of wavelet vectors using a multidimensional mixture of generalized Gaussian (MMGG) densities. (author)

  5. Contributions in compression of 3D medical images and 2D images; Contributions en compression d'images medicales 3D et d'images naturelles 2D

    Energy Technology Data Exchange (ETDEWEB)

    Gaudeau, Y

    2006-12-15

    The huge amounts of volumetric data generated by current medical imaging techniques in the context of an increasing demand for long term archiving solutions, as well as the rapid development of distant radiology make the use of compression inevitable. Indeed, if the medical community has sided until now with compression without losses, most of applications suffer from compression ratios which are too low with this kind of compression. In this context, compression with acceptable losses could be the most appropriate answer. So, we propose a new loss coding scheme based on 3D (3 dimensional) Wavelet Transform and Dead Zone Lattice Vector Quantization 3D (DZLVQ) for medical images. Our algorithm has been evaluated on several computerized tomography (CT) and magnetic resonance image volumes. The main contribution of this work is the design of a multidimensional dead zone which enables to take into account correlations between neighbouring elementary volumes. At high compression ratios, we show that it can out-perform visually and numerically the best existing methods. These promising results are confirmed on head CT by two medical patricians. The second contribution of this document assesses the effect with-loss image compression on CAD (Computer-Aided Decision) detection performance of solid lung nodules. This work on 120 significant lungs images shows that detection did not suffer until 48:1 compression and still was robust at 96:1. The last contribution consists in the complexity reduction of our compression scheme. The first allocation dedicated to 2D DZLVQ uses an exponential of the rate-distortion (R-D) functions. The second allocation for 2D and 3D medical images is based on block statistical model to estimate the R-D curves. These R-D models are based on the joint distribution of wavelet vectors using a multidimensional mixture of generalized Gaussian (MMGG) densities. (author)

  6. Image-based RSA: Roentgen stereophotogrammetric analysis based on 2D-3D image registration.

    Science.gov (United States)

    de Bruin, P W; Kaptein, B L; Stoel, B C; Reiber, J H C; Rozing, P M; Valstar, E R

    2008-01-01

    Image-based Roentgen stereophotogrammetric analysis (IBRSA) integrates 2D-3D image registration and conventional RSA. Instead of radiopaque RSA bone markers, IBRSA uses 3D CT data, from which digitally reconstructed radiographs (DRRs) are generated. Using 2D-3D image registration, the 3D pose of the CT is iteratively adjusted such that the generated DRRs resemble the 2D RSA images as closely as possible, according to an image matching metric. Effectively, by registering all 2D follow-up moments to the same 3D CT, the CT volume functions as common ground. In two experiments, using RSA and using a micromanipulator as gold standard, IBRSA has been validated on cadaveric and sawbone scapula radiographs, and good matching results have been achieved. The accuracy was: |mu |RSA but higher than in vivo standard RSA. Because IBRSA does not require radiopaque markers, it adds functionality to the RSA method by opening new directions and possibilities for research, such as dynamic analyses using fluoroscopy on subjects without markers and computer navigation applications.

  7. 2D-3D image registration in diagnostic and interventional X-Ray imaging

    NARCIS (Netherlands)

    Bom, I.M.J. van der

    2010-01-01

    Clinical procedures that are conventionally guided by 2D x-ray imaging, may benefit from the additional spatial information provided by 3D image data. For instance, guidance of minimally invasive procedures with CT or MRI data provides 3D spatial information and visualization of structures that are

  8. HDR IMAGING FOR FEATURE DETECTION ON DETAILED ARCHITECTURAL SCENES

    Directory of Open Access Journals (Sweden)

    G. Kontogianni

    2015-02-01

    Full Text Available 3D reconstruction relies on accurate detection, extraction, description and matching of image features. This is even truer for complex architectural scenes that pose needs for 3D models of high quality, without any loss of detail in geometry or color. Illumination conditions influence the radiometric quality of images, as standard sensors cannot depict properly a wide range of intensities in the same scene. Indeed, overexposed or underexposed pixels cause irreplaceable information loss and degrade digital representation. Images taken under extreme lighting environments may be thus prohibitive for feature detection/extraction and consequently for matching and 3D reconstruction. High Dynamic Range (HDR images could be helpful for these operators because they broaden the limits of illumination range that Standard or Low Dynamic Range (SDR/LDR images can capture and increase in this way the amount of details contained in the image. Experimental results of this study prove this assumption as they examine state of the art feature detectors applied both on standard dynamic range and HDR images.

  9. Contributions in compression of 3D medical images and 2D images

    International Nuclear Information System (INIS)

    Gaudeau, Y.

    2006-12-01

    The huge amounts of volumetric data generated by current medical imaging techniques in the context of an increasing demand for long term archiving solutions, as well as the rapid development of distant radiology make the use of compression inevitable. Indeed, if the medical community has sided until now with compression without losses, most of applications suffer from compression ratios which are too low with this kind of compression. In this context, compression with acceptable losses could be the most appropriate answer. So, we propose a new loss coding scheme based on 3D (3 dimensional) Wavelet Transform and Dead Zone Lattice Vector Quantization 3D (DZLVQ) for medical images. Our algorithm has been evaluated on several computerized tomography (CT) and magnetic resonance image volumes. The main contribution of this work is the design of a multidimensional dead zone which enables to take into account correlations between neighbouring elementary volumes. At high compression ratios, we show that it can out-perform visually and numerically the best existing methods. These promising results are confirmed on head CT by two medical patricians. The second contribution of this document assesses the effect with-loss image compression on CAD (Computer-Aided Decision) detection performance of solid lung nodules. This work on 120 significant lungs images shows that detection did not suffer until 48:1 compression and still was robust at 96:1. The last contribution consists in the complexity reduction of our compression scheme. The first allocation dedicated to 2D DZLVQ uses an exponential of the rate-distortion (R-D) functions. The second allocation for 2D and 3D medical images is based on block statistical model to estimate the R-D curves. These R-D models are based on the joint distribution of wavelet vectors using a multidimensional mixture of generalized Gaussian (MMGG) densities. (author)

  10. Automatic Contour Extraction from 2D Image

    Directory of Open Access Journals (Sweden)

    Panagiotis GIOANNIS

    2011-03-01

    Full Text Available Aim: To develop a method for automatic contour extraction from a 2D image. Material and Method: The method is divided in two basic parts where the user initially chooses the starting point and the threshold. Finally the method is applied to computed tomography of bone images. Results: An interesting method is developed which can lead to a successful boundary extraction of 2D images. Specifically data extracted from a computed tomography images can be used for 2D bone reconstruction. Conclusions: We believe that such an algorithm or part of it can be applied on several other applications for shape feature extraction in medical image analysis and generally at computer graphics.

  11. Coupled Dictionary Learning for the Detail-Enhanced Synthesis of 3-D Facial Expressions.

    Science.gov (United States)

    Liang, Haoran; Liang, Ronghua; Song, Mingli; He, Xiaofei

    2016-04-01

    The desire to reconstruct 3-D face models with expressions from 2-D face images fosters increasing interest in addressing the problem of face modeling. This task is important and challenging in the field of computer animation. Facial contours and wrinkles are essential to generate a face with a certain expression; however, these details are generally ignored or are not seriously considered in previous studies on face model reconstruction. Thus, we employ coupled radius basis function networks to derive an intermediate 3-D face model from a single 2-D face image. To optimize the 3-D face model further through landmarks, a coupled dictionary that is related to 3-D face models and their corresponding 3-D landmarks is learned from the given training set through local coordinate coding. Another coupled dictionary is then constructed to bridge the 2-D and 3-D landmarks for the transfer of vertices on the face model. As a result, the final 3-D face can be generated with the appropriate expression. In the testing phase, the 2-D input faces are converted into 3-D models that display different expressions. Experimental results indicate that the proposed approach to facial expression synthesis can obtain model details more effectively than previous methods can.

  12. 3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy to the 2D cross-sectional images

    International Nuclear Information System (INIS)

    Rodt, T.; Ratiu, P.; Kacher, D.F.; Anderson, M.; Jolesz, F.A.; Kikinis, R.; Becker, H.; Bartling, S.

    2002-01-01

    The 3D imaging of the middle ear facilitates better understanding of the patient's anatomy. Cross-sectional slices, however, often allow a more accurate evaluation of anatomical structures, as some detail may be lost through post-processing. In order to demonstrate the advantages of combining both approaches, we performed computed tomography (CT) imaging in two normal and 15 different pathological cases, and the 3D models were correlated to the cross-sectional CT slices. Reconstructed CT datasets were acquired by multi-slice CT. Post-processing was performed using the in-house software ''3D Slicer'', applying thresholding and manual segmentation. 3D models of the individual anatomical structures were generated and displayed in different colours. The display of relevant anatomical and pathological structures was evaluated in the greyscale 2D slices, 3D images, and the 2D slices showing the segmented 2D anatomy in different colours for each structure. Correlating 2D slices to the 3D models and virtual endoscopy helps to combine the advantages of each method. As generating 3D models can be extremely time-consuming, this approach can be a clinically applicable way of gaining a 3D understanding of the patient's anatomy by using models as a reference. Furthermore, it can help radiologists and otolaryngologists evaluating the 2D slices by adding the correct 3D information that would otherwise have to be mentally integrated. The method can be applied to radiological diagnosis, surgical planning, and especially, to teaching. (orig.)

  13. Performance evaluation of 2D image registration algorithms with the numeric image registration and comparison platform

    International Nuclear Information System (INIS)

    Gerganov, G.; Kuvandjiev, V.; Dimitrova, I.; Mitev, K.; Kawrakow, I.

    2012-01-01

    The objective of this work is to present the capabilities of the NUMERICS web platform for evaluation of the performance of image registration algorithms. The NUMERICS platform is a web accessible tool which provides access to dedicated numerical algorithms for registration and comparison of medical images (http://numerics.phys.uni-sofia.bg). The platform allows comparison of noisy medical images by means of different types of image comparison algorithms, which are based on statistical tests for outliers. The platform also allows 2D image registration with different techniques like Elastic Thin-Plate Spline registration, registration based on rigid transformations, affine transformations, as well as non-rigid image registration based on Mobius transformations. In this work we demonstrate how the platform can be used as a tool for evaluation of the quality of the image registration process. We demonstrate performance evaluation of a deformable image registration technique based on Mobius transformations. The transformations are applied with appropriate cost functions like: Mutual information, Correlation coefficient, Sum of Squared Differences. The accent is on the results provided by the platform to the user and their interpretation in the context of the performance evaluation of 2D image registration. The NUMERICS image registration and image comparison platform provides detailed statistical information about submitted image registration jobs and can be used to perform quantitative evaluation of the performance of different image registration techniques. (authors)

  14. 2D sparse array transducer optimization for 3D ultrasound imaging

    International Nuclear Information System (INIS)

    Choi, Jae Hoon; Park, Kwan Kyu

    2014-01-01

    A 3D ultrasound image is desired in many medical examinations. However, the implementation of a 2D array, which is needed for a 3D image, is challenging with respect to fabrication, interconnection and cabling. A 2D sparse array, which needs fewer elements than a dense array, is a realistic way to achieve 3D images. Because the number of ways the elements can be placed in an array is extremely large, a method for optimizing the array configuration is needed. Previous research placed the target point far from the transducer array, making it impossible to optimize the array in the operating range. In our study, we focused on optimizing a 2D sparse array transducer for 3D imaging by using a simulated annealing method. We compared the far-field optimization method with the near-field optimization method by analyzing a point-spread function (PSF). The resolution of the optimized sparse array is comparable to that of the dense array.

  15. WE-AB-BRA-07: Quantitative Evaluation of 2D-2D and 2D-3D Image Guided Radiation Therapy for Clinical Trial Credentialing, NRG Oncology/RTOG

    Energy Technology Data Exchange (ETDEWEB)

    Giaddui, T; Yu, J; Xiao, Y [Thomas Jefferson University, Philadelphia, PA (United States); Jacobs, P [MIM Software, Inc, Cleavland, Ohio (United States); Manfredi, D; Linnemann, N [IROC Philadelphia, RTQA Center, Philadelphia, PA (United States)

    2015-06-15

    Purpose: 2D-2D kV image guided radiation therapy (IGRT) credentialing evaluation for clinical trial qualification was historically qualitative through submitting screen captures of the fusion process. However, as quantitative DICOM 2D-2D and 2D-3D image registration tools are implemented in clinical practice for better precision, especially in centers that treat patients with protons, better IGRT credentialing techniques are needed. The aim of this work is to establish methodologies for quantitatively reviewing IGRT submissions based on DICOM 2D-2D and 2D-3D image registration and to test the methodologies in reviewing 2D-2D and 2D-3D IGRT submissions for RTOG/NRG Oncology clinical trials qualifications. Methods: DICOM 2D-2D and 2D-3D automated and manual image registration have been tested using the Harmony tool in MIM software. 2D kV orthogonal portal images are fused with the reference digital reconstructed radiographs (DRR) in the 2D-2D registration while the 2D portal images are fused with DICOM planning CT image in the 2D-3D registration. The Harmony tool allows alignment of the two images used in the registration process and also calculates the required shifts. Shifts calculated using MIM are compared with those submitted by institutions for IGRT credentialing. Reported shifts are considered to be acceptable if differences are less than 3mm. Results: Several tests have been performed on the 2D-2D and 2D-3D registration. The results indicated good agreement between submitted and calculated shifts. A workflow for reviewing these IGRT submissions has been developed and will eventually be used to review IGRT submissions. Conclusion: The IROC Philadelphia RTQA center has developed and tested a new workflow for reviewing DICOM 2D-2D and 2D-3D IGRT credentialing submissions made by different cancer clinical centers, especially proton centers. NRG Center for Innovation in Radiation Oncology (CIRO) and IROC RTQA center continue their collaborative efforts to enhance

  16. WE-AB-BRA-07: Quantitative Evaluation of 2D-2D and 2D-3D Image Guided Radiation Therapy for Clinical Trial Credentialing, NRG Oncology/RTOG

    International Nuclear Information System (INIS)

    Giaddui, T; Yu, J; Xiao, Y; Jacobs, P; Manfredi, D; Linnemann, N

    2015-01-01

    Purpose: 2D-2D kV image guided radiation therapy (IGRT) credentialing evaluation for clinical trial qualification was historically qualitative through submitting screen captures of the fusion process. However, as quantitative DICOM 2D-2D and 2D-3D image registration tools are implemented in clinical practice for better precision, especially in centers that treat patients with protons, better IGRT credentialing techniques are needed. The aim of this work is to establish methodologies for quantitatively reviewing IGRT submissions based on DICOM 2D-2D and 2D-3D image registration and to test the methodologies in reviewing 2D-2D and 2D-3D IGRT submissions for RTOG/NRG Oncology clinical trials qualifications. Methods: DICOM 2D-2D and 2D-3D automated and manual image registration have been tested using the Harmony tool in MIM software. 2D kV orthogonal portal images are fused with the reference digital reconstructed radiographs (DRR) in the 2D-2D registration while the 2D portal images are fused with DICOM planning CT image in the 2D-3D registration. The Harmony tool allows alignment of the two images used in the registration process and also calculates the required shifts. Shifts calculated using MIM are compared with those submitted by institutions for IGRT credentialing. Reported shifts are considered to be acceptable if differences are less than 3mm. Results: Several tests have been performed on the 2D-2D and 2D-3D registration. The results indicated good agreement between submitted and calculated shifts. A workflow for reviewing these IGRT submissions has been developed and will eventually be used to review IGRT submissions. Conclusion: The IROC Philadelphia RTQA center has developed and tested a new workflow for reviewing DICOM 2D-2D and 2D-3D IGRT credentialing submissions made by different cancer clinical centers, especially proton centers. NRG Center for Innovation in Radiation Oncology (CIRO) and IROC RTQA center continue their collaborative efforts to enhance

  17. Methodological development of topographic correction in 2D/3D ToF-SIMS images using AFM images

    Science.gov (United States)

    Jung, Seokwon; Lee, Nodo; Choi, Myungshin; Lee, Jungmin; Cho, Eunkyunng; Joo, Minho

    2018-02-01

    Time-of-flight secondary-ion mass spectrometry (ToF-SIMS) is an emerging technique that provides chemical information directly from the surface of electronic materials, e.g. OLED and solar cell. It is very versatile and highly sensitive mass spectrometric technique that provides surface molecular information with their lateral distribution as a two-dimensional (2D) molecular image. Extending the usefulness of ToF-SIMS, a 3D molecular image can be generated by acquiring multiple 2D images in a stack. These imaging techniques by ToF-SIMS provide an insight into understanding the complex structures of unknown composition in electronic material. However, one drawback in ToF-SIMS is not able to represent topographical information in 2D and 3D mapping images. To overcome this technical limitation, topographic information by ex-situ technique such as atomic force microscopy (AFM) has been combined with chemical information from SIMS that provides both chemical and physical information in one image. The key to combine two different images obtained from ToF-SIMS and AFM techniques is to develop the image processing algorithm, which performs resize and alignment by comparing the specific pixel information of each image. In this work, we present methodological development of the semiautomatic alignment and the 3D structure interpolation system for the combination of 2D/3D images obtained by ToF-SIMS and AFM measurements, which allows providing useful analytical information in a single representation.

  18. Reproducing 2D breast mammography images with 3D printed phantoms

    Science.gov (United States)

    Clark, Matthew; Ghammraoui, Bahaa; Badal, Andreu

    2016-03-01

    Mammography is currently the standard imaging modality used to screen women for breast abnormalities and, as a result, it is a tool of great importance for the early detection of breast cancer. Physical phantoms are commonly used as surrogates of breast tissue to evaluate some aspects of the performance of mammography systems. However, most phantoms do not reproduce the anatomic heterogeneity of real breasts. New fabrication technologies, such as 3D printing, have created the opportunity to build more complex, anatomically realistic breast phantoms that could potentially assist in the evaluation of mammography systems. The primary objective of this work is to present a simple, easily reproducible methodology to design and print 3D objects that replicate the attenuation profile observed in real 2D mammograms. The secondary objective is to evaluate the capabilities and limitations of the competing 3D printing technologies, and characterize the x-ray properties of the different materials they use. Printable phantoms can be created using the open-source code introduced in this work, which processes a raw mammography image to estimate the amount of x-ray attenuation at each pixel, and outputs a triangle mesh object that encodes the observed attenuation map. The conversion from the observed pixel gray value to a column of printed material with equivalent attenuation requires certain assumptions and knowledge of multiple imaging system parameters, such as x-ray energy spectrum, source-to-object distance, compressed breast thickness, and average breast material attenuation. A detailed description of the new software, a characterization of the printed materials using x-ray spectroscopy, and an evaluation of the realism of the sample printed phantoms are presented.

  19. 3D dynamic pituitary MR imaging with CAIPIRINHA: Initial experience and comparison with 2D dynamic MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fushimi, Yasutaka, E-mail: yfushimi@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Okada, Tomohisa; Kanagaki, Mitsunori; Yamamoto, Akira; Kanda, Yumiko; Sakamoto, Ryo [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Hojo, Masato; Takahashi, Jun C.; Miyamoto, Susumu [Department of Neurosurgery, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan); Togashi, Kaori [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto 606-8507 (Japan)

    2014-10-15

    Objectives: To evaluate the validity of 3D dynamic pituitary MR imaging with controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA), with special emphasis on demarcation of pituitary posterior lobe and stalk. Methods: Participants comprised 32 patients who underwent dynamic pituitary MR imaging due to pituitary or parasellar lesions. 3D dynamic MR with CAIPIRINHA was performed at 3 T with 20-s-interval, precontrast, 1st to 5th dynamic images. Normalized values and enhanced ratios (dynamic postcontrast image values divided by precontrast ones) were compared between 3D and 2D dynamic MR imaging for patients with visual identification of posterior lobe and stalk. Results: In 3D, stalk was identified in 29 patients and unidentified in 3, and posterior lobe was identified in 28 and unidentified in 4. In 2D, stalk was identified in 26 patients and unidentified in 6 patients, and posterior lobe was identified in 15 and unidentified in 17. Normalized values of pituitary posterior lobe and stalk were higher in 3D than 2D (P < 0.001). No significant difference in enhancement ratio was seen between 3D and 2D. Conclusions: 3D dynamic pituitary MR provided better identification and higher normalized values of pituitary posterior lobe and stalk than 2D.

  20. 2D-Driven 3D Object Detection in RGB-D Images

    KAUST Repository

    Lahoud, Jean

    2017-12-25

    In this paper, we present a technique that places 3D bounding boxes around objects in an RGB-D scene. Our approach makes best use of the 2D information to quickly reduce the search space in 3D, benefiting from state-of-the-art 2D object detection techniques. We then use the 3D information to orient, place, and score bounding boxes around objects. We independently estimate the orientation for every object, using previous techniques that utilize normal information. Object locations and sizes in 3D are learned using a multilayer perceptron (MLP). In the final step, we refine our detections based on object class relations within a scene. When compared to state-of-the-art detection methods that operate almost entirely in the sparse 3D domain, extensive experiments on the well-known SUN RGB-D dataset [29] show that our proposed method is much faster (4.1s per image) in detecting 3D objects in RGB-D images and performs better (3 mAP higher) than the state-of-the-art method that is 4.7 times slower and comparably to the method that is two orders of magnitude slower. This work hints at the idea that 2D-driven object detection in 3D should be further explored, especially in cases where the 3D input is sparse.

  1. 3D-2D Deformable Image Registration Using Feature-Based Nonuniform Meshes.

    Science.gov (United States)

    Zhong, Zichun; Guo, Xiaohu; Cai, Yiqi; Yang, Yin; Wang, Jing; Jia, Xun; Mao, Weihua

    2016-01-01

    By using prior information of planning CT images and feature-based nonuniform meshes, this paper demonstrates that volumetric images can be efficiently registered with a very small portion of 2D projection images of a Cone-Beam Computed Tomography (CBCT) scan. After a density field is computed based on the extracted feature edges from planning CT images, nonuniform tetrahedral meshes will be automatically generated to better characterize the image features according to the density field; that is, finer meshes are generated for features. The displacement vector fields (DVFs) are specified at the mesh vertices to drive the deformation of original CT images. Digitally reconstructed radiographs (DRRs) of the deformed anatomy are generated and compared with corresponding 2D projections. DVFs are optimized to minimize the objective function including differences between DRRs and projections and the regularity. To further accelerate the above 3D-2D registration, a procedure to obtain good initial deformations by deforming the volume surface to match 2D body boundary on projections has been developed. This complete method is evaluated quantitatively by using several digital phantoms and data from head and neck cancer patients. The feature-based nonuniform meshing method leads to better results than either uniform orthogonal grid or uniform tetrahedral meshes.

  2. 3D-2D Deformable Image Registration Using Feature-Based Nonuniform Meshes

    Directory of Open Access Journals (Sweden)

    Zichun Zhong

    2016-01-01

    Full Text Available By using prior information of planning CT images and feature-based nonuniform meshes, this paper demonstrates that volumetric images can be efficiently registered with a very small portion of 2D projection images of a Cone-Beam Computed Tomography (CBCT scan. After a density field is computed based on the extracted feature edges from planning CT images, nonuniform tetrahedral meshes will be automatically generated to better characterize the image features according to the density field; that is, finer meshes are generated for features. The displacement vector fields (DVFs are specified at the mesh vertices to drive the deformation of original CT images. Digitally reconstructed radiographs (DRRs of the deformed anatomy are generated and compared with corresponding 2D projections. DVFs are optimized to minimize the objective function including differences between DRRs and projections and the regularity. To further accelerate the above 3D-2D registration, a procedure to obtain good initial deformations by deforming the volume surface to match 2D body boundary on projections has been developed. This complete method is evaluated quantitatively by using several digital phantoms and data from head and neck cancer patients. The feature-based nonuniform meshing method leads to better results than either uniform orthogonal grid or uniform tetrahedral meshes.

  3. Computer assisted determination of acetabular cup orientation using 2D-3D image registration

    International Nuclear Information System (INIS)

    Zheng, Guoyan; Zhang, Xuan

    2010-01-01

    2D-3D image-based registration methods have been developed to measure acetabular cup orientation after total hip arthroplasty (THA). These methods require registration of both the prosthesis and the CT images to 2D radiographs and compute implant position with respect to a reference. The application of these methods is limited in clinical practice due to two limitations: (1) the requirement of a computer-aided design (CAD) model of the prosthesis, which may be unavailable due to the proprietary concerns of the manufacturer, and (2) the requirement of either multiple radiographs or radiograph-specific calibration, usually unavailable for retrospective studies. In this paper, we propose a new method to address these limitations. A new formulation for determination of post-operative cup orientation, which couples a radiographic measurement with 2D-3D image matching, was developed. In our formulation, the radiographic measurement can be obtained with known methods so that the challenge lies in the 2D-3D image matching. To solve this problem, a hybrid 2D-3D registration scheme combining a landmark-to-ray 2D-3D alignment with a robust intensity-based 2D-3D registration was used. The hybrid 2D-3D registration scheme allows computing both the post-operative cup orientation with respect to an anatomical reference and the pelvic tilt and rotation with respect to the X-ray imaging table/plate. The method was validated using 2D adult cadaver hips. Using the hybrid 2D-3D registration scheme, our method showed a mean accuracy of 1.0 ± 0.7 (range from 0.1 to 2.0 ) for inclination and 1.7 ± 1.2 (range from 0.0 to 3.9 ) for anteversion, taking the measurements from post-operative CT images as ground truths. Our new solution formulation and the hybrid 2D-3D registration scheme facilitate estimation of post-operative cup orientation and measurement of pelvic tilt and rotation. (orig.)

  4. Using Integrated 2D and 3D Resistivity Imaging Methods for Illustrating the Mud-Fluid Conduits of the Wushanting Mud Volcanoes in Southwestern Taiwan

    Directory of Open Access Journals (Sweden)

    Ping-Yu Chang

    2011-01-01

    Full Text Available We conducted 2D and 3D looped resistivity surveys in the Wushanting Natural Landscape Preservation Area (WNLPA in order to understand the relationships of the mud-fluid conduits in the mud volcano system. 2D resistivity surveys were conducted along seven networked lines. Two separate C-shape looped electrode arrays surrounding the volcano craters were used in the study. First, the two 3D looped measurements were inverted separately. Yet the inverted 3D images of the mud-volcano system were inconsistent with the landscape features suggesting that artifacts perhaps appeared in the images. The 3D looped data were then combined with the 2D data for creating a global resistivity model of WNLPA. The resulting 3D image is consistent with the observed landscape features. With the resistivity model of WNLPA, we further tried to estimate the distribution of water content. The results suggest that the 3D resistivity image has the potential to resolve the dual porosity structures in the mudstone area. Last, we used a simplified WNLPA model for forward simulation in order to verify the field measurement results. We have concluded that the artifacts in the 3D looped images are in fact shadow effects from conductive objects out of the electrode loops, and that inverted images of combined 2D and 3D data provide detailed regional conductive structures in the WNLPA site.

  5. Efficient Sample Delay Calculation for 2-D and 3-D Ultrasound Imaging.

    Science.gov (United States)

    Ibrahim, Aya; Hager, Pascal A; Bartolini, Andrea; Angiolini, Federico; Arditi, Marcel; Thiran, Jean-Philippe; Benini, Luca; De Micheli, Giovanni

    2017-08-01

    Ultrasound imaging is a reference medical diagnostic technique, thanks to its blend of versatility, effectiveness, and moderate cost. The core computation of all ultrasound imaging methods is based on simple formulae, except for those required to calculate acoustic propagation delays with high precision and throughput. Unfortunately, advanced three-dimensional (3-D) systems require the calculation or storage of billions of such delay values per frame, which is a challenge. In 2-D systems, this requirement can be four orders of magnitude lower, but efficient computation is still crucial in view of low-power implementations that can be battery-operated, enabling usage in numerous additional scenarios. In this paper, we explore two smart designs of the delay generation function. To quantify their hardware cost, we implement them on FPGA and study their footprint and performance. We evaluate how these architectures scale to different ultrasound applications, from a low-power 2-D system to a next-generation 3-D machine. When using numerical approximations, we demonstrate the ability to generate delay values with sufficient throughput to support 10 000-channel 3-D imaging at up to 30 fps while using 63% of a Virtex 7 FPGA, requiring 24 MB of external memory accessed at about 32 GB/s bandwidth. Alternatively, with similar FPGA occupation, we show an exact calculation method that reaches 24 fps on 1225-channel 3-D imaging and does not require external memory at all. Both designs can be scaled to use a negligible amount of resources for 2-D imaging in low-power applications and for ultrafast 2-D imaging at hundreds of frames per second.

  6. 2-d spectroscopic imaging of brain tumours

    International Nuclear Information System (INIS)

    Ferris, N.J.; Brotchie, P.R.

    2002-01-01

    Full text: This poster illustrates the use of two-dimensional spectroscopic imaging (2-D SI) in the characterisation of brain tumours, and the monitoring of subsequent treatment. After conventional contrast-enhanced MR imaging of patients with known or suspected brain tumours, 2-D SI is performed at a single axial level. The level is chosen to include the maximum volume of abnormal enhancement, or, in non-enhancing lesions. The most extensive T2 signal abnormality. Two different MR systems have been used (Marconi Edge and GE Signa LX); at each site, a PRESS localisation sequence is employed with TE 128-144 ms. Automated software is used to generate spectral arrays, metabolite maps, and metabolite ratio maps from the spectroscopic data. Colour overlays of the maps onto anatomical images are produced using manufacturer software or the Medex imaging data analysis package. High grade gliomas showed choline levels higher than those in apparently normal brain, with decreases in NAA and creatine. Some lesions showed spectral abnormality extending into otherwise normal appearing brain. This was also seen in a case of CNS lymphoma. Lowgrade lesions showed choline levels similar to normal brain, but with decreased NAA. Only a small number of metastases have been studied, but to date no metastasis has shown spectral abnormality beyond the margins suggested by conventional imaging. Follow-up studies generally show spectral heterogeneity. Regions with choline levels higher than those in normal-appearing brain are considered to represent recurrent high-grade tumour. Some regions show choline to be the dominant metabolite, but its level is not greater than that seen in normal brain. These regions are considered suspicious for residual / recurrent tumour when the choline / creatine ratio exceeds 2 (lower ratios may represent treatment effect). 2-D SI improves the initial assessment of brain tumours, and has potential for influencing the radiotherapy treatment strategy. 2-D SI also

  7. Advanced 3-D Ultrasound Imaging: 3-D Synthetic Aperture Imaging using Fully Addressed and Row-Column Addressed 2-D Transducer Arrays

    DEFF Research Database (Denmark)

    Bouzari, Hamed

    the important diagnostic information in a noninvasive manner. Diagnostic and therapeutic decisions often require accurate estimates of e.g., organ, cyst, or tumor volumes. 3-D ultrasound imaging can provide these measurements without relying on the geometrical assumptions and operator-dependent skills involved...... is one of the factors for the widespread use of ultrasound imaging. The high price tag on the high quality 3-D scanners is limiting their market share. Row-column addressing of 2-D transducer arrays is a low cost alternative to fully addressed 2-D arrays, for 3-D ultrasound imaging. Using row....... Based on a set of acoustical measurements the center frequency, bandwidth, surface pressure, sensitivity, and acoustical cross-talks were evaluated and discussed. The imaging quality assessments were carried out based on Field II simulations as well as phantom measurements. Moreover, an analysis...

  8. 3-D Imaging using Row--Column-Addressed 2-D Arrays with a Diverging Lens

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Engholm, Mathias; Stuart, Matthias Bo

    2016-01-01

    It has been shown that row–column-addressed (RCA) 2-D arrays can be an inexpensive alternative to fully addressed 2-D arrays. Generally imaging with an RCA 2-D array is limited to its forward-looking volume region. Constructing a double-curved RCA 2-D array or applying a diverging lens over......, is designed for imaging down to 14 cm at a volume rate of 88 Hz. The curvilinear imaging performance of a λ/2-pitch 3 MHz 62+62 RCA 2-D array is investigated as a function of depth, using a diverging lens with f-number of -1. The results of this study demonstrate that the proposed beamforming approach...

  9. Progressive attenuation fields: Fast 2D-3D image registration without precomputation

    International Nuclear Information System (INIS)

    Rohlfing, Torsten; Russakoff, Daniel B.; Denzler, Joachim; Mori, Kensaku; Maurer, Calvin R. Jr.

    2005-01-01

    Computation of digitally reconstructed radiograph (DRR) images is the rate-limiting step in most current intensity-based algorithms for the registration of three-dimensional (3D) images to two-dimensional (2D) projection images. This paper introduces and evaluates the progressive attenuation field (PAF), which is a new method to speed up DRR computation. A PAF is closely related to an attenuation field (AF). A major difference is that a PAF is constructed on the fly as the registration proceeds; it does not require any precomputation time, nor does it make any prior assumptions of the patient pose or limit the permissible range of patient motion. A PAF effectively acts as a cache memory for projection values once they are computed, rather than as a lookup table for precomputed projections like standard AFs. We use a cylindrical attenuation field parametrization, which is better suited for many medical applications of 2D-3D registration than the usual two-plane parametrization. The computed attenuation values are stored in a hash table for time-efficient storage and access. Using clinical gold-standard spine image data sets from five patients, we demonstrate consistent speedups of intensity-based 2D-3D image registration using PAF DRRs by a factor of 10 over conventional ray casting DRRs with no decrease of registration accuracy or robustness

  10. 3D FaceCam: a fast and accurate 3D facial imaging device for biometrics applications

    Science.gov (United States)

    Geng, Jason; Zhuang, Ping; May, Patrick; Yi, Steven; Tunnell, David

    2004-08-01

    Human faces are fundamentally three-dimensional (3D) objects, and each face has its unique 3D geometric profile. The 3D geometric features of a human face can be used, together with its 2D texture, for rapid and accurate face recognition purposes. Due to the lack of low-cost and robust 3D sensors and effective 3D facial recognition (FR) algorithms, almost all existing FR systems use 2D face images. Genex has developed 3D solutions that overcome the inherent problems in 2D while also addressing limitations in other 3D alternatives. One important aspect of our solution is a unique 3D camera (the 3D FaceCam) that combines multiple imaging sensors within a single compact device to provide instantaneous, ear-to-ear coverage of a human face. This 3D camera uses three high-resolution CCD sensors and a color encoded pattern projection system. The RGB color information from each pixel is used to compute the range data and generate an accurate 3D surface map. The imaging system uses no moving parts and combines multiple 3D views to provide detailed and complete 3D coverage of the entire face. Images are captured within a fraction of a second and full-frame 3D data is produced within a few seconds. This described method provides much better data coverage and accuracy in feature areas with sharp features or details (such as the nose and eyes). Using this 3D data, we have been able to demonstrate that a 3D approach can significantly improve the performance of facial recognition. We have conducted tests in which we have varied the lighting conditions and angle of image acquisition in the "field." These tests have shown that the matching results are significantly improved when enrolling a 3D image rather than a single 2D image. With its 3D solutions, Genex is working toward unlocking the promise of powerful 3D FR and transferring FR from a lab technology into a real-world biometric solution.

  11. Acquiring a 2D rolled equivalent fingerprint image from a non-contact 3D finger scan

    Science.gov (United States)

    Fatehpuria, Abhishika; Lau, Daniel L.; Hassebrook, Laurence G.

    2006-04-01

    The use of fingerprints as a biometric is both the oldest mode of computer aided personal identification and the most relied-upon technology in use today. But current fingerprint scanning systems have some challenging and peculiar difficulties. Often skin conditions and imperfect acquisition circumstances cause the captured fingerprint image to be far from ideal. Also some of the acquisition techniques can be slow and cumbersome to use and may not provide the complete information required for reliable feature extraction and fingerprint matching. Most of the difficulties arise due to the contact of the fingerprint surface with the sensor platen. To attain a fast-capture, non-contact, fingerprint scanning technology, we are developing a scanning system that employs structured light illumination as a means for acquiring a 3-D scan of the finger with sufficiently high resolution to record ridge-level details. In this paper, we describe the postprocessing steps used for converting the acquired 3-D scan of the subject's finger into a 2-D rolled equivalent image.

  12. Clinical applications of 2D and 3D CT imaging of the airways - a review

    International Nuclear Information System (INIS)

    Salvolini, Luca; Bichi Secchi, Elisabetta; Costarelli, Leonardo; De Nicola, Maurizio

    2000-01-01

    Hardware and software evolution has broadened the possibilities of 2D and 3D reformatting of spiral CT and MR data set. In the study of the thorax, intrinsic benefits of volumetric CT scanning and better quality of reconstructed images offer us the possibility to apply additional rendering techniques to everyday clinical practice. Considering the large number and redundancy of possible post-processing imaging techniques that we can apply to raw CT sections data, it is necessary to precisely set a well-defined number of clinical applications of each of them, by careful evaluation of their benefits and possible pitfalls in each clinical setting. In diagnostic evaluation of pathological processes affecting the airways, a huge number of thin sections is necessary for detailed appraisal and has to be evaluated, and information must then be transferred to referring clinicians. By additional rendering it is possible to make image evaluation and data transfer easier, faster, and more effective. In the study of central airways, additional rendering can be of interest for precise evaluation of the length, morphology, and degree of stenoses. It may help in depicting exactly the locoregional extent of central tumours by better display of relations with bronchovascular interfaces and can increase CT/bronchoscopy sinergy. It may allow closer radiotherapy planning and better depiction of air collections, and, finally, it could ease panoramic evaluation of the results of dynamic or functional studies, that are made possible by increased speed of spiral scanning. When applied to the evaluation of peripheral airways, as a completion to conventional HRCT scans, High-Resolution Volumetric CT, by projection slabs applied to target areas of interest, can better depict the profusion and extension of affected bronchial segments in bronchiectasis, influence the choice of different approaches for tissue sampling by better evaluation of the relations of lung nodules with the airways, or help

  13. Clinical applications of 2D and 3D CT imaging of the airways - a review

    Energy Technology Data Exchange (ETDEWEB)

    Salvolini, Luca E-mail: u.salvolini@popcsi.unian.it; Bichi Secchi, Elisabetta; Costarelli, Leonardo; De Nicola, Maurizio

    2000-04-01

    Hardware and software evolution has broadened the possibilities of 2D and 3D reformatting of spiral CT and MR data set. In the study of the thorax, intrinsic benefits of volumetric CT scanning and better quality of reconstructed images offer us the possibility to apply additional rendering techniques to everyday clinical practice. Considering the large number and redundancy of possible post-processing imaging techniques that we can apply to raw CT sections data, it is necessary to precisely set a well-defined number of clinical applications of each of them, by careful evaluation of their benefits and possible pitfalls in each clinical setting. In diagnostic evaluation of pathological processes affecting the airways, a huge number of thin sections is necessary for detailed appraisal and has to be evaluated, and information must then be transferred to referring clinicians. By additional rendering it is possible to make image evaluation and data transfer easier, faster, and more effective. In the study of central airways, additional rendering can be of interest for precise evaluation of the length, morphology, and degree of stenoses. It may help in depicting exactly the locoregional extent of central tumours by better display of relations with bronchovascular interfaces and can increase CT/bronchoscopy sinergy. It may allow closer radiotherapy planning and better depiction of air collections, and, finally, it could ease panoramic evaluation of the results of dynamic or functional studies, that are made possible by increased speed of spiral scanning. When applied to the evaluation of peripheral airways, as a completion to conventional HRCT scans, High-Resolution Volumetric CT, by projection slabs applied to target areas of interest, can better depict the profusion and extension of affected bronchial segments in bronchiectasis, influence the choice of different approaches for tissue sampling by better evaluation of the relations of lung nodules with the airways, or help

  14. Detail Enhancement for Infrared Images Based on Propagated Image Filter

    Directory of Open Access Journals (Sweden)

    Yishu Peng

    2016-01-01

    Full Text Available For displaying high-dynamic-range images acquired by thermal camera systems, 14-bit raw infrared data should map into 8-bit gray values. This paper presents a new method for detail enhancement of infrared images to display the image with a relatively satisfied contrast and brightness, rich detail information, and no artifacts caused by the image processing. We first adopt a propagated image filter to smooth the input image and separate the image into the base layer and the detail layer. Then, we refine the base layer by using modified histogram projection for compressing. Meanwhile, the adaptive weights derived from the layer decomposition processing are used as the strict gain control for the detail layer. The final display result is obtained by recombining the two modified layers. Experimental results on both cooled and uncooled infrared data verify that the proposed method outperforms the method based on log-power histogram modification and bilateral filter-based detail enhancement in both detail enhancement and visual effect.

  15. Imaging system for creating 3D block-face cryo-images of whole mice

    Science.gov (United States)

    Roy, Debashish; Breen, Michael; Salvado, Olivier; Heinzel, Meredith; McKinley, Eliot; Wilson, David

    2006-03-01

    We developed a cryomicrotome/imaging system that provides high resolution, high sensitivity block-face images of whole mice or excised organs, and applied it to a variety of biological applications. With this cryo-imaging system, we sectioned cryo-preserved tissues at 2-40 μm thickness and acquired high resolution brightfield and fluorescence images with microscopic in-plane resolution (as good as 1.2 μm). Brightfield images of normal and pathological anatomy show exquisite detail, especially in the abdominal cavity. Multi-planar reformatting and 3D renderings allow one to interrogate 3D structures. In this report, we present brightfield images of mouse anatomy, as well as 3D renderings of organs. For BPK mice model of polycystic kidney disease, we compared brightfield cryo-images and kidney volumes to MRI. The color images provided greater contrast and resolution of cysts as compared to in vivo MRI. We note that color cryo-images are closer to what a researcher sees in dissection, making it easier for them to interpret image data. The combination of field of view, depth of field, ultra high resolution and color/fluorescence contrast enables cryo-image volumes to provide details that cannot be found through in vivo imaging or other ex vivo optical imaging approaches. We believe that this novel imaging system will have applications that include identification of mouse phenotypes, characterization of diseases like blood vessel disease, kidney disease, and cancer, assessment of drug and gene therapy delivery and efficacy and validation of other imaging modalities.

  16. 2D vs. 3D imaging in laparoscopic surgery-results of a prospective randomized trial.

    Science.gov (United States)

    Buia, Alexander; Stockhausen, Florian; Filmann, Natalie; Hanisch, Ernst

    2017-12-01

    3D imaging is an upcoming technology in laparoscopic surgery, and recent studies have shown that the modern 3D technique is superior in an experimental setting. However, the first randomized controlled clinical trial in this context dates back to 1998 and showed no significant difference between 2D and 3D visualization using the first 3D generation technique, which is now more than 15 years old. Positive results measured in an experimental setting considering 3D imaging on surgical performance led us to initiate a randomized controlled pragmatic clinical trial to validate our findings in daily clinical routine. Standard laparoscopic operations (cholecystectomy, appendectomy) were preoperatively randomized to a 2D or 3D imaging system. We used a surgical comfort scale (Likert scale) and the Raw NASA Workload TLX for the subjective assessment of 2D and 3D imaging; the duration of surgery was also measured. The results of 3D imaging were statistically significant better than 2D imaging concerning the parameters "own felt safety" and "task efficiency"; the difficulty level of the procedures in the 2D and 3D groups did not differ. Overall, the Raw NASA Workload TLX showed no significance between the groups. 3D imaging could be a possible advantage in laparoscopic surgery. The results of our clinical trial show increased personal felt safety and efficiency of the surgeon using a 3D imaging system. Overall of the procedures, the findings assessed using Likert scales in terms of own felt safety and task efficiency were statistically significant for 3D imaging. The individually perceived workload assessed with the Raw NASA TLX shows no difference. Although these findings are subjective impressions of the performing surgeons without a clear benefit for 3D technology in clinical outcome, we think that these results show the capability that 3D laparoscopy can have a positive impact while performing laparoscopic procedures.

  17. Wide area 2D/3D imaging development, analysis and applications

    CERN Document Server

    Langmann, Benjamin

    2014-01-01

    Imaging technology is an important research area and it is widely utilized in a growing number of disciplines ranging from gaming, robotics and automation to medicine. In the last decade 3D imaging became popular mainly driven by the introduction of novel 3D cameras and measuring devices. These cameras are usually limited to indoor scenes with relatively low distances. Benjamin Langmann introduces medium and long-range 2D/3D cameras to overcome these limitations. He reports measurement results for these devices and studies their characteristic behavior. In order to facilitate the application o

  18. 3D T2-weighted imaging to shorten multiparametric prostate MRI protocols.

    Science.gov (United States)

    Polanec, Stephan H; Lazar, Mathias; Wengert, Georg J; Bickel, Hubert; Spick, Claudio; Susani, Martin; Shariat, Shahrokh; Clauser, Paola; Baltzer, Pascal A T

    2018-04-01

    To determine whether 3D acquisitions provide equivalent image quality, lesion delineation quality and PI-RADS v2 performance compared to 2D acquisitions in T2-weighted imaging of the prostate at 3 T. This IRB-approved, prospective study included 150 consecutive patients (mean age 63.7 years, 35-84 years; mean PSA 7.2 ng/ml, 0.4-31.1 ng/ml). Two uroradiologists (R1, R2) independently rated image quality and lesion delineation quality using a five-point ordinal scale and assigned a PI-RADS score for 2D and 3D T2-weighted image data sets. Data were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/area under the curve (AUC) analysis. Image quality was similarly good to excellent for 2D T2w (mean score R1, 4.3 ± 0.81; R2, 4.7 ± 0.83) and 3D T2w (mean score R1, 4.3 ± 0.82; R2, 4.7 ± 0.69), p = 0.269. Lesion delineation was rated good to excellent for 2D (mean score R1, 4.16 ± 0.81; R2, 4.19 ± 0.92) and 3D T2w (R1, 4.19 ± 0.94; R2, 4.27 ± 0.94) without significant differences (p = 0.785). ROC analysis showed an equivalent performance for 2D (AUC 0.580-0.623) and 3D (AUC 0.576-0.629) T2w (p > 0.05, respectively). Three-dimensional acquisitions demonstrated equivalent image and lesion delineation quality, and PI-RADS v2 performance, compared to 2D in T2-weighted imaging of the prostate. Three-dimensional T2-weighted imaging could be used to considerably shorten prostate MRI protocols in clinical practice. • 3D shows equivalent image quality and lesion delineation compared to 2D T2w. • 3D T2w and 2D T2w image acquisition demonstrated comparable diagnostic performance. • Using a single 3D T2w acquisition may shorten the protocol by 40%. • Combined with short DCE, multiparametric protocols of 10 min are feasible.

  19. Image recovery from defocused 2D fluorescent images in multimodal digital holographic microscopy.

    Science.gov (United States)

    Quan, Xiangyu; Matoba, Osamu; Awatsuji, Yasuhiro

    2017-05-01

    A technique of three-dimensional (3D) intensity retrieval from defocused, two-dimensional (2D) fluorescent images in the multimodal digital holographic microscopy (DHM) is proposed. In the multimodal DHM, 3D phase and 2D fluorescence distributions are obtained simultaneously by an integrated system of an off-axis DHM and a conventional epifluorescence microscopy, respectively. This gives us more information of the target; however, defocused fluorescent images are observed due to the short depth of field. In this Letter, we propose a method to recover the defocused images based on the phase compensation and backpropagation from the defocused plane to the focused plane using the distance information that is obtained from a 3D phase distribution. By applying Zernike polynomial phase correction, we brought back the fluorescence intensity to the focused imaging planes. The experimental demonstration using fluorescent beads is presented, and the expected applications are suggested.

  20. Evaluation of a breast software model for 2D and 3D X-ray imaging studies of the breast.

    Science.gov (United States)

    Baneva, Yanka; Bliznakova, Kristina; Cockmartin, Lesley; Marinov, Stoyko; Buliev, Ivan; Mettivier, Giovanni; Bosmans, Hilde; Russo, Paolo; Marshall, Nicholas; Bliznakov, Zhivko

    2017-09-01

    In X-ray imaging, test objects reproducing breast anatomy characteristics are realized to optimize issues such as image processing or reconstruction, lesion detection performance, image quality and radiation induced detriment. Recently, a physical phantom with a structured background has been introduced for both 2D mammography and breast tomosynthesis. A software version of this phantom and a few related versions are now available and a comparison between these 3D software phantoms and the physical phantom will be presented. The software breast phantom simulates a semi-cylindrical container filled with spherical beads of different diameters. Four computational breast phantoms were generated with a dedicated software application and for two of these, physical phantoms are also available and they are used for the side by side comparison. Planar projections in mammography and tomosynthesis were simulated under identical incident air kerma conditions. Tomosynthesis slices were reconstructed with an in-house developed reconstruction software. In addition to a visual comparison, parameters like fractal dimension, power law exponent β and second order statistics (skewness, kurtosis) of planar projections and tomosynthesis reconstructed images were compared. Visually, an excellent agreement between simulated and real planar and tomosynthesis images is observed. The comparison shows also an overall very good agreement between parameters evaluated from simulated and experimental images. The computational breast phantoms showed a close match with their physical versions. The detailed mathematical analysis of the images confirms the agreement between real and simulated 2D mammography and tomosynthesis images. The software phantom is ready for optimization purpose and extrapolation of the phantom to other breast imaging techniques. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. A fast, accurate, and automatic 2D-3D image registration for image-guided cranial radiosurgery

    International Nuclear Information System (INIS)

    Fu Dongshan; Kuduvalli, Gopinath

    2008-01-01

    The authors developed a fast and accurate two-dimensional (2D)-three-dimensional (3D) image registration method to perform precise initial patient setup and frequent detection and correction for patient movement during image-guided cranial radiosurgery treatment. In this method, an approximate geometric relationship is first established to decompose a 3D rigid transformation in the 3D patient coordinate into in-plane transformations and out-of-plane rotations in two orthogonal 2D projections. Digitally reconstructed radiographs are generated offline from a preoperative computed tomography volume prior to treatment and used as the reference for patient position. A multiphase framework is designed to register the digitally reconstructed radiographs with the x-ray images periodically acquired during patient setup and treatment. The registration in each projection is performed independently; the results in the two projections are then combined and converted to a 3D rigid transformation by 2D-3D geometric backprojection. The in-plane transformation and the out-of-plane rotation are estimated using different search methods, including multiresolution matching, steepest descent minimization, and one-dimensional search. Two similarity measures, optimized pattern intensity and sum of squared difference, are applied at different registration phases to optimize accuracy and computation speed. Various experiments on an anthropomorphic head-and-neck phantom showed that, using fiducial registration as a gold standard, the registration errors were 0.33±0.16 mm (s.d.) in overall translation and 0.29 deg. ±0.11 deg. (s.d.) in overall rotation. The total targeting errors were 0.34±0.16 mm (s.d.), 0.40±0.2 mm (s.d.), and 0.51±0.26 mm (s.d.) for the targets at the distances of 2, 6, and 10 cm from the rotation center, respectively. The computation time was less than 3 s on a computer with an Intel Pentium 3.0 GHz dual processor

  2. 2D VS 3D imaging of brain tumours with 18F-Fluoromisonidazole (FMISO) and positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Pathmaraj, K.; Scott, A.M.; Egan, G.F.; Hannah, A.; Tauro, A.; Tochon-Danguy, A.; Sachinidis, J.; Berlangieri, S.U.; Fabinyi, G.; McKay, W.J.; Cher, L.

    1998-01-01

    Full text: 18 F-FMISO accumulates in hypoxic cells and can be used in the PET imaging of brain tumours containing viable but hypoxic cells. The limited activity (typically 130 MBq) of injected 18 F-FMISO yield poor statistics, requiring prolonged imaging in the conventional 2D mode of PET scanning. 3D (septa retracted) imaging allows for more counts to be collected over a shorter time period making it a more practical alternative. This study investigates the contrast resolution that can be obtained from 3D PET scans compared to the corresponding 2D scan. A patient recently diagnosed with brain tumour was injected with 18 -FMISO 2 hours prior to scanning and imaged supine on a 951/31R PET scanner with the head secured firmly in a head holder. The imaging protocol consisted of a 3 min emission rectilinear scan to position the brain in the FOV, a 10 min post-emission transmission scan, a 20 min 2D emission scan and a 5X10 min frames 3D emission scan. Both the 2D and 3D scans were reconstructed with filtered backprojection algorithm. The first 10 min frame of the 3D acquisition was reconstructed. The total true counts were 3 million and 6.06 million in the 2D image and 3D images respectively. The random events were 0.24 million and 0.96 million in the 2D and 3D images respectively. The Noise Equivalent Counts (NEC) were 2.2 million and 2.02 million for the 2D and 3D images respectively indicating that the 2D and 3D scans (in spite of the nominal true events being vastly different in the 2 scans) had similar Signal to Noise Ratio (SNR). Circular ROI's were defined in the tumour and the contralateral cortex in comparable transaxial slices of the 2D and 3D images. Contrast resolution of the tumour to the background was calculated as 1.4 and 1.38 in the 2D and 3D images respectively. Thus comparable contrast resolution is obtained in the brain with both 3D and 2D images, making 3D imaging a viable alternative to 2D imaging and greatly reducing imaging time. Optimum time

  3. Comparison of modern 3D and 2D MR imaging sequences of the wrist at 3 Tesla

    International Nuclear Information System (INIS)

    Rehnitz, C.; Klaan, B.; Amarteifio, E.; Kauczor, H.U.; Weber, M.A.; Stillfried, F. von; Burkholder, I.

    2016-01-01

    To compare the image quality of modern 3 D and 2 D sequences for dedicated wrist imaging at 3 Tesla (T) MRI. At 3 T MRI, 18 patients (mean age: 36.2 years) with wrist pain and 16 healthy volunteers (mean age: 26.4 years) were examined using 2 D proton density-weighted fat-saturated (PDfs), isotropic 3 D TrueFISP, 3 D MEDIC, and 3 D PDfs SPACE sequences. Image quality was rated on a five-point scale (0 - 4) including overall image quality (OIQ), visibility of important structures (cartilage, ligaments, TFCC) and degree of artifacts. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) of cartilage/bone/muscle/fluid as well as the mean overall SNR/CNR were calculated using region-of-interest analysis. ANOVA, paired t-, and Wilcoxon-signed-rank tests were applied. The image quality of all tested sequences was superior to 3 D PDfs SPACE (p < 0.01). 3 D TrueFISP had the highest combined cartilage score (mean: 3.4) and performed better in cartilage comparisons against 3 D PDfs SPACE in both groups and 2 D PDfs in volunteers (p < 0.05). 3 D MEDIC performed better in 7 of 8 comparisons (p < 0.05) regarding ligaments and TFCC. 2 D PDfs provided constantly high scores. The mean overall SNR/CNR for 2 D PDfs, 3 D PDfs SPACE, 3 D TrueFISP, and 3 D MEDIC were 68/65, 32/27, 45/47, and 57/45, respectively. 2 D PDfs performed best in most SNR/CNR comparisons (p < 0.05) and 3 D MEDIC performed best within the 3 D sequences (p < 0.05). Except 3 D PDfs SPACE, all tested 3 D and 2 D sequences provided high image quality. 3 D TrueFISP was best for cartilage imaging, 3 D MEDIC for ligaments and TFCC and 2 D PDfs for general wrist imaging.

  4. A novel image fusion algorithm based on 2D scale-mixing complex wavelet transform and Bayesian MAP estimation for multimodal medical images

    Directory of Open Access Journals (Sweden)

    Abdallah Bengueddoudj

    2017-05-01

    Full Text Available In this paper, we propose a new image fusion algorithm based on two-dimensional Scale-Mixing Complex Wavelet Transform (2D-SMCWT. The fusion of the detail 2D-SMCWT coefficients is performed via a Bayesian Maximum a Posteriori (MAP approach by considering a trivariate statistical model for the local neighboring of 2D-SMCWT coefficients. For the approximation coefficients, a new fusion rule based on the Principal Component Analysis (PCA is applied. We conduct several experiments using three different groups of multimodal medical images to evaluate the performance of the proposed method. The obtained results prove the superiority of the proposed method over the state of the art fusion methods in terms of visual quality and several commonly used metrics. Robustness of the proposed method is further tested against different types of noise. The plots of fusion metrics establish the accuracy of the proposed fusion method.

  5. Volumetric Synthetic Aperture Imaging with a Piezoelectric 2-D Row-Column Probe

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Engholm, Mathias; Christiansen, Thomas Lehrmann

    2016-01-01

    The synthetic aperture (SA) technique can be used for achieving real-time volumetric ultrasound imaging using 2-D row-column addressed transducers. This paper investigates SA volumetric imaging performance of an in-house prototyped 3 MHz λ/2-pitch 62+62 element piezoelectric 2-D row-column addres......The synthetic aperture (SA) technique can be used for achieving real-time volumetric ultrasound imaging using 2-D row-column addressed transducers. This paper investigates SA volumetric imaging performance of an in-house prototyped 3 MHz λ/2-pitch 62+62 element piezoelectric 2-D row...

  6. Simultaneous 3D–2D image registration and C-arm calibration: Application to endovascular image-guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Mitrović, Uroš [Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, Ljubljana 1000, Slovenia and Cosylab, Control System Laboratory, Teslova ulica 30, Ljubljana 1000 (Slovenia); Pernuš, Franjo [Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, Ljubljana 1000 (Slovenia); Likar, Boštjan; Špiclin, Žiga, E-mail: ziga.spiclin@fe.uni-lj.si [Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, Ljubljana 1000, Slovenia and Sensum, Computer Vision Systems, Tehnološki Park 21, Ljubljana 1000 (Slovenia)

    2015-11-15

    Purpose: Three-dimensional to two-dimensional (3D–2D) image registration is a key to fusion and simultaneous visualization of valuable information contained in 3D pre-interventional and 2D intra-interventional images with the final goal of image guidance of a procedure. In this paper, the authors focus on 3D–2D image registration within the context of intracranial endovascular image-guided interventions (EIGIs), where the 3D and 2D images are generally acquired with the same C-arm system. The accuracy and robustness of any 3D–2D registration method, to be used in a clinical setting, is influenced by (1) the method itself, (2) uncertainty of initial pose of the 3D image from which registration starts, (3) uncertainty of C-arm’s geometry and pose, and (4) the number of 2D intra-interventional images used for registration, which is generally one and at most two. The study of these influences requires rigorous and objective validation of any 3D–2D registration method against a highly accurate reference or “gold standard” registration, performed on clinical image datasets acquired in the context of the intervention. Methods: The registration process is split into two sequential, i.e., initial and final, registration stages. The initial stage is either machine-based or template matching. The latter aims to reduce possibly large in-plane translation errors by matching a projection of the 3D vessel model and 2D image. In the final registration stage, four state-of-the-art intrinsic image-based 3D–2D registration methods, which involve simultaneous refinement of rigid-body and C-arm parameters, are evaluated. For objective validation, the authors acquired an image database of 15 patients undergoing cerebral EIGI, for which accurate gold standard registrations were established by fiducial marker coregistration. Results: Based on target registration error, the obtained success rates of 3D to a single 2D image registration after initial machine-based and

  7. Extracting 3D parametric curves from 2D images of helical objects.

    OpenAIRE

    Willcocks, Chris; Jackson, Philip T.G.; Nelson, Carl J.; Obara, Boguslaw

    2016-01-01

    Helical objects occur in medicine, biology, cosmetics, nanotechnology, and engineering. Extracting a 3D parametric curve from a 2D image of a helical object has many practical applications, in particular being able to extract metrics such as tortuosity, frequency, and pitch. We present a method that is able to straighten the image object and derive a robust 3D helical curve from peaks in the object boundary. The algorithm has a small number of stable parameters that require little tuning, and...

  8. Estimating 3D Object Parameters from 2D Grey-Level Images

    NARCIS (Netherlands)

    Houkes, Z.

    2000-01-01

    This thesis describes a general framework for parameter estimation, which is suitable for computer vision applications. The approach described combines 3D modelling, animation and estimation tools to determine parameters of objects in a scene from 2D grey-level images. The animation tool predicts

  9. A multi-frequency electrical impedance tomography system for real-time 2D and 3D imaging

    Science.gov (United States)

    Yang, Yunjie; Jia, Jiabin

    2017-08-01

    This paper presents the design and evaluation of a configurable, fast multi-frequency Electrical Impedance Tomography (mfEIT) system for real-time 2D and 3D imaging, particularly for biomedical imaging. The system integrates 32 electrode interfaces and the current frequency ranges from 10 kHz to 1 MHz. The system incorporates the following novel features. First, a fully adjustable multi-frequency current source with current monitoring function is designed. Second, a flexible switching scheme is developed for arbitrary sensing configuration and a semi-parallel data acquisition architecture is implemented for high-frame-rate data acquisition. Furthermore, multi-frequency digital quadrature demodulation is accomplished in a high-capacity Field Programmable Gate Array. At last, a 3D imaging software, visual tomography, is developed for real-time 2D and 3D image reconstruction, data analysis, and visualization. The mfEIT system is systematically tested and evaluated from the aspects of signal to noise ratio (SNR), frame rate, and 2D and 3D multi-frequency phantom imaging. The highest SNR is 82.82 dB on a 16-electrode sensor. The frame rate is up to 546 fps at serial mode and 1014 fps at semi-parallel mode. The evaluation results indicate that the presented mfEIT system is a powerful tool for real-time 2D and 3D imaging.

  10. Complex adaptation-based LDR image rendering for 3D image reconstruction

    Science.gov (United States)

    Lee, Sung-Hak; Kwon, Hyuk-Ju; Sohng, Kyu-Ik

    2014-07-01

    A low-dynamic tone-compression technique is developed for realistic image rendering that can make three-dimensional (3D) images similar to realistic scenes by overcoming brightness dimming in the 3D display mode. The 3D surround provides varying conditions for image quality, illuminant adaptation, contrast, gamma, color, sharpness, and so on. In general, gain/offset adjustment, gamma compensation, and histogram equalization have performed well in contrast compression; however, as a result of signal saturation and clipping effects, image details are removed and information is lost on bright and dark areas. Thus, an enhanced image mapping technique is proposed based on space-varying image compression. The performance of contrast compression is enhanced with complex adaptation in a 3D viewing surround combining global and local adaptation. Evaluating local image rendering in view of tone and color expression, noise reduction, and edge compensation confirms that the proposed 3D image-mapping model can compensate for the loss of image quality in the 3D mode.

  11. 2D imaging and 3D sensing data acquisition and mutual registration for painting conservation

    Science.gov (United States)

    Fontana, Raffaella; Gambino, Maria Chiara; Greco, Marinella; Marras, Luciano; Pampaloni, Enrico M.; Pelagotti, Anna; Pezzati, Luca; Poggi, Pasquale

    2005-01-01

    We describe the application of 2D and 3D data acquisition and mutual registration to the conservation of paintings. RGB color image acquisition, IR and UV fluorescence imaging, together with the more recent hyperspectral imaging (32 bands) are among the most useful techniques in this field. They generally are meant to provide information on the painting materials, on the employed techniques and on the object state of conservation. However, only when the various images are perfectly registered on each other and on the 3D model, no ambiguity is possible and safe conclusions may be drawn. We present the integration of 2D and 3D measurements carried out on two different paintings: "Madonna of the Yarnwinder" by Leonardo da Vinci, and "Portrait of Lionello d'Este", by Pisanello, both painted in the XV century.

  12. Improved Focusing Method for 3-D Imaging using Row–Column-Addressed 2-D Arrays

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Engholm, Mathias; Stuart, Matthias Bo

    2017-01-01

    A row–column-addressed (RCA) 2-D array can be interpreted as two orthogonal 1-D arrays. By transmitting with row elements and receiving the echoes through column elements or vice versa, a rectilinear volume in front of the array can be beamformed. Since the transmit and receive 1-D arrays are ort...... measurements with a PZT λ/2-pitch 3 MHz 62+62 RCA 2-D transducer probe. A synthetic aperture imaging sequence with single element transmissions at a time, is designed for imaging down to 14 cm at a volume rate of 44 Hz....

  13. Optimization of PET image quality by means of 3D data acquisition and iterative image reconstruction

    International Nuclear Information System (INIS)

    Doll, J.; Zaers, J.; Trojan, H.; Bellemann, M.E.; Adam, L.E.; Haberkorn, U.; Brix, G.

    1998-01-01

    The experiments were performed at the latest-generation whole-body PET system ECAT EXACT HR + . For 2D data acquisition, a collimator of thin tungsten septa was positioned in the field-of-view. Prior to image reconstruction, the measured 3D data were sorted into 2D sinograms by using the Fourier rebinning (FORE) algorithm developed by M. Defrise. The standard filtered backprojection (FBP) method and an optimized ML/EM algorithm with overrelaxation for accelerated convergence were employed for image reconstruction. The spatial resolution of both methods as well as the convergence and noise properties of the ML/EM algorithm were studied in phantom measurements. Furthermore, patient data were acquired in the 2D mode as well as in the 3D mode and reconstructed with both techniques. At the same spatial resolution, the ML/EM-reconstructed images showed fewer and less prominent artefacts than the FBP-reconstructed images. The resulting improved detail conspicuously was achieved for the data acquired in the 2D mode as well as in the 3D mode. The best image quality was obtained by iterative 2D reconstruction of 3D data sets which were previously rebinned into 2D sinograms with help of the FORE algorithm. The phantom measurements revealed that 50 iteration steps with the otpimized ML/EM algorithm were sufficient to keep the relative quantitation error below 5%. (orig./MG) [de

  14. 3D-2D registration in endovascular image-guided surgery: evaluation of state-of-the-art methods on cerebral angiograms.

    Science.gov (United States)

    Mitrović, Uroš; Likar, Boštjan; Pernuš, Franjo; Špiclin, Žiga

    2018-02-01

    Image guidance for minimally invasive surgery is based on spatial co-registration and fusion of 3D pre-interventional images and treatment plans with the 2D live intra-interventional images. The spatial co-registration or 3D-2D registration is the key enabling technology; however, the performance of state-of-the-art automated methods is rather unclear as they have not been assessed under the same test conditions. Herein we perform a quantitative and comparative evaluation of ten state-of-the-art methods for 3D-2D registration on a public dataset of clinical angiograms. Image database consisted of 3D and 2D angiograms of 25 patients undergoing treatment for cerebral aneurysms or arteriovenous malformations. On each of the datasets, highly accurate "gold-standard" registrations of 3D and 2D images were established based on patient-attached fiducial markers. The database was used to rigorously evaluate ten state-of-the-art 3D-2D registration methods, namely two intensity-, two gradient-, three feature-based and three hybrid methods, both for registration of 3D pre-interventional image to monoplane or biplane 2D images. Intensity-based methods were most accurate in all tests (0.3 mm). One of the hybrid methods was most robust with 98.75% of successful registrations (SR) and capture range of 18 mm for registrations of 3D to biplane 2D angiograms. In general, registration accuracy was similar whether registration of 3D image was performed onto mono- or biplanar 2D images; however, the SR was substantially lower in case of 3D to monoplane 2D registration. Two feature-based and two hybrid methods had clinically feasible execution times in the order of a second. Performance of methods seems to fall below expectations in terms of robustness in case of registration of 3D to monoplane 2D images, while translation into clinical image guidance systems seems readily feasible for methods that perform registration of the 3D pre-interventional image onto biplanar intra

  15. SU-D-BRA-03: Analysis of Systematic Errors with 2D/3D Image Registration for Target Localization and Treatment Delivery in Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Xu, H; Chetty, I; Wen, N

    2016-01-01

    Purpose: Determine systematic deviations between 2D/3D and 3D/3D image registrations with six degrees of freedom (6DOF) for various imaging modalities and registration algorithms on the Varian Edge Linac. Methods: The 6DOF systematic errors were assessed by comparing automated 2D/3D (kV/MV vs. CT) with 3D/3D (CBCT vs. CT) image registrations from different imaging pairs, CT slice thicknesses, couch angles, similarity measures, etc., using a Rando head and a pelvic phantom. The 2D/3D image registration accuracy was evaluated at different treatment sites (intra-cranial and extra-cranial) by statistically analyzing 2D/3D pre-treatment verification against 3D/3D localization of 192 Stereotactic Radiosurgery/Stereotactic Body Radiation Therapy treatment fractions for 88 patients. Results: The systematic errors of 2D/3D image registration using kV-kV, MV-kV and MV-MV image pairs using 0.8 mm slice thickness CT images were within 0.3 mm and 0.3° for translations and rotations with a 95% confidence interval (CI). No significant difference between 2D/3D and 3D/3D image registrations (P>0.05) was observed for target localization at various CT slice thicknesses ranging from 0.8 to 3 mm. Couch angles (30, 45, 60 degree) did not impact the accuracy of 2D/3D image registration. Using pattern intensity with content image filtering was recommended for 2D/3D image registration to achieve the best accuracy. For the patient study, translational error was within 2 mm and rotational error was within 0.6 degrees in terms of 95% CI for 2D/3D image registration. For intra-cranial sites, means and std. deviations of translational errors were −0.2±0.7, 0.04±0.5, 0.1±0.4 mm for LNG, LAT, VRT directions, respectively. For extra-cranial sites, means and std. deviations of translational errors were - 0.04±1, 0.2±1, 0.1±1 mm for LNG, LAT, VRT directions, respectively. 2D/3D image registration uncertainties for intra-cranial and extra-cranial sites were comparable. Conclusion: The Varian

  16. SU-D-BRA-03: Analysis of Systematic Errors with 2D/3D Image Registration for Target Localization and Treatment Delivery in Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Xu, H [Wayne State University, Detroit, MI (United States); Chetty, I; Wen, N [Henry Ford Health System, Detroit, MI (United States)

    2016-06-15

    Purpose: Determine systematic deviations between 2D/3D and 3D/3D image registrations with six degrees of freedom (6DOF) for various imaging modalities and registration algorithms on the Varian Edge Linac. Methods: The 6DOF systematic errors were assessed by comparing automated 2D/3D (kV/MV vs. CT) with 3D/3D (CBCT vs. CT) image registrations from different imaging pairs, CT slice thicknesses, couch angles, similarity measures, etc., using a Rando head and a pelvic phantom. The 2D/3D image registration accuracy was evaluated at different treatment sites (intra-cranial and extra-cranial) by statistically analyzing 2D/3D pre-treatment verification against 3D/3D localization of 192 Stereotactic Radiosurgery/Stereotactic Body Radiation Therapy treatment fractions for 88 patients. Results: The systematic errors of 2D/3D image registration using kV-kV, MV-kV and MV-MV image pairs using 0.8 mm slice thickness CT images were within 0.3 mm and 0.3° for translations and rotations with a 95% confidence interval (CI). No significant difference between 2D/3D and 3D/3D image registrations (P>0.05) was observed for target localization at various CT slice thicknesses ranging from 0.8 to 3 mm. Couch angles (30, 45, 60 degree) did not impact the accuracy of 2D/3D image registration. Using pattern intensity with content image filtering was recommended for 2D/3D image registration to achieve the best accuracy. For the patient study, translational error was within 2 mm and rotational error was within 0.6 degrees in terms of 95% CI for 2D/3D image registration. For intra-cranial sites, means and std. deviations of translational errors were −0.2±0.7, 0.04±0.5, 0.1±0.4 mm for LNG, LAT, VRT directions, respectively. For extra-cranial sites, means and std. deviations of translational errors were - 0.04±1, 0.2±1, 0.1±1 mm for LNG, LAT, VRT directions, respectively. 2D/3D image registration uncertainties for intra-cranial and extra-cranial sites were comparable. Conclusion: The Varian

  17. Extracting 3D Parametric Curves from 2D Images of Helical Objects.

    Science.gov (United States)

    Willcocks, Chris G; Jackson, Philip T G; Nelson, Carl J; Obara, Boguslaw

    2017-09-01

    Helical objects occur in medicine, biology, cosmetics, nanotechnology, and engineering. Extracting a 3D parametric curve from a 2D image of a helical object has many practical applications, in particular being able to extract metrics such as tortuosity, frequency, and pitch. We present a method that is able to straighten the image object and derive a robust 3D helical curve from peaks in the object boundary. The algorithm has a small number of stable parameters that require little tuning, and the curve is validated against both synthetic and real-world data. The results show that the extracted 3D curve comes within close Hausdorff distance to the ground truth, and has near identical tortuosity for helical objects with a circular profile. Parameter insensitivity and robustness against high levels of image noise are demonstrated thoroughly and quantitatively.

  18. Measurable realistic image-based 3D mapping

    Science.gov (United States)

    Liu, W.; Wang, J.; Wang, J. J.; Ding, W.; Almagbile, A.

    2011-12-01

    Maps with 3D visual models are becoming a remarkable feature of 3D map services. High-resolution image data is obtained for the construction of 3D visualized models.The3D map not only provides the capabilities of 3D measurements and knowledge mining, but also provides the virtual experienceof places of interest, such as demonstrated in the Google Earth. Applications of 3D maps are expanding into the areas of architecture, property management, and urban environment monitoring. However, the reconstruction of high quality 3D models is time consuming, and requires robust hardware and powerful software to handle the enormous amount of data. This is especially for automatic implementation of 3D models and the representation of complicated surfacesthat still need improvements with in the visualisation techniques. The shortcoming of 3D model-based maps is the limitation of detailed coverage since a user can only view and measure objects that are already modelled in the virtual environment. This paper proposes and demonstrates a 3D map concept that is realistic and image-based, that enables geometric measurements and geo-location services. Additionally, image-based 3D maps provide more detailed information of the real world than 3D model-based maps. The image-based 3D maps use geo-referenced stereo images or panoramic images. The geometric relationships between objects in the images can be resolved from the geometric model of stereo images. The panoramic function makes 3D maps more interactive with users but also creates an interesting immersive circumstance. Actually, unmeasurable image-based 3D maps already exist, such as Google street view, but only provide virtual experiences in terms of photos. The topographic and terrain attributes, such as shapes and heights though are omitted. This paper also discusses the potential for using a low cost land Mobile Mapping System (MMS) to implement realistic image 3D mapping, and evaluates the positioning accuracy that a measureable

  19. FluoRender: An application of 2D image space methods for 3D and 4D confocal microscopy data visualization in neurobiology research

    KAUST Repository

    Wan, Yong; Otsuna, Hideo; Chien, Chi-Bin; Hansen, Charles

    2012-01-01

    2D image space methods are processing methods applied after the volumetric data are projected and rendered into the 2D image space, such as 2D filtering, tone mapping and compositing. In the application domain of volume visualization, most 2D image space methods can be carried out more efficiently than their 3D counterparts. Most importantly, 2D image space methods can be used to enhance volume visualization quality when applied together with volume rendering methods. In this paper, we present and discuss the applications of a series of 2D image space methods as enhancements to confocal microscopy visualizations, including 2D tone mapping, 2D compositing, and 2D color mapping. These methods are easily integrated with our existing confocal visualization tool, FluoRender, and the outcome is a full-featured visualization system that meets neurobiologists' demands for qualitative analysis of confocal microscopy data. © 2012 IEEE.

  20. FluoRender: An application of 2D image space methods for 3D and 4D confocal microscopy data visualization in neurobiology research

    KAUST Repository

    Wan, Yong

    2012-02-01

    2D image space methods are processing methods applied after the volumetric data are projected and rendered into the 2D image space, such as 2D filtering, tone mapping and compositing. In the application domain of volume visualization, most 2D image space methods can be carried out more efficiently than their 3D counterparts. Most importantly, 2D image space methods can be used to enhance volume visualization quality when applied together with volume rendering methods. In this paper, we present and discuss the applications of a series of 2D image space methods as enhancements to confocal microscopy visualizations, including 2D tone mapping, 2D compositing, and 2D color mapping. These methods are easily integrated with our existing confocal visualization tool, FluoRender, and the outcome is a full-featured visualization system that meets neurobiologists\\' demands for qualitative analysis of confocal microscopy data. © 2012 IEEE.

  1. Clinical evaluation of 2D versus 3D whole-body PET image quality using a dedicated BGO PET scanner

    International Nuclear Information System (INIS)

    Visvikis, D.; Griffiths, D.; Costa, D.C.; Bomanji, J.; Ell, P.J.

    2005-01-01

    Three-dimensional positron emission tomography (3D PET) results in higher system sensitivity, with an associated increase in the detection of scatter and random coincidences. The objective of this work was to compare, from a clinical perspective, 3D and two-dimensional (2D) acquisitions in terms of whole-body (WB) PET image quality with a dedicated BGO PET system. 2D and 3D WB emission acquisitions were carried out in 70 patients. Variable acquisition parameters in terms of time of emission acquisition per axial field of view (aFOV) and slice overlap between sequential aFOVs were used during the 3D acquisitions. 3D and 2D images were reconstructed using FORE+WLS and OSEM respectively. Scatter correction was performed by convolution subtraction and a model-based scatter correction in 2D and 3D respectively. All WB images were attenuation corrected using segmented transmission scans. Images were blindly assessed by three observers for the presence of artefacts, confidence in lesion detection and overall image quality using a scoring system. Statistically significant differences between 2D and 3D image quality were only obtained for 3D emission acquisitions of 3 min. No statistically significant differences were observed for image artefacts or lesion detectability scores. Image quality correlated significantly with patient weight for both modes of operation. Finally, no differences were seen in image artefact scores for the different axial slice overlaps considered, suggesting the use of five slice overlaps in 3D WB acquisitions. 3D WB imaging using a dedicated BGO-based PET scanner offers similar image quality to that obtained in 2D considering similar overall times of acquisitions. (orig.)

  2. Registration of 2D C-Arm and 3D CT Images for a C-Arm Image-Assisted Navigation System for Spinal Surgery

    Directory of Open Access Journals (Sweden)

    Chih-Ju Chang

    2015-01-01

    Full Text Available C-Arm image-assisted surgical navigation system has been broadly applied to spinal surgery. However, accurate path planning on the C-Arm AP-view image is difficult. This research studies 2D-3D image registration methods to obtain the optimum transformation matrix between C-Arm and CT image frames. Through the transformation matrix, the surgical path planned on preoperative CT images can be transformed and displayed on the C-Arm images for surgical guidance. The positions of surgical instruments will also be displayed on both CT and C-Arm in the real time. Five similarity measure methods of 2D-3D image registration including Normalized Cross-Correlation, Gradient Correlation, Pattern Intensity, Gradient Difference Correlation, and Mutual Information combined with three optimization methods including Powell’s method, Downhill simplex algorithm, and genetic algorithm are applied to evaluate their performance in converge range, efficiency, and accuracy. Experimental results show that the combination of Normalized Cross-Correlation measure method with Downhill simplex algorithm obtains maximum correlation and similarity in C-Arm and Digital Reconstructed Radiograph (DRR images. Spine saw bones are used in the experiment to evaluate 2D-3D image registration accuracy. The average error in displacement is 0.22 mm. The success rate is approximately 90% and average registration time takes 16 seconds.

  3. Curvilinear 3-D Imaging Using Row--Column-Addressed 2-D Arrays with a Diverging Lens: Feasibility Study

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Engholm, Mathias; Beers, Christopher

    2017-01-01

    imaging. Extended FOV and low channel count of double-curved RCA 2-D arrays make 3-D imaging possible with equipment in the price range of conventional 2-D imaging. This study proposes a delay-and-sum beamformation scheme specific to double-curved RCA 2-D arrays and validates its focusing ability based...... of this study demonstrate that the proposed beamforming approach is accurate for achieving correct time-of-flight calculations, and hence avoids geometrical distortions....

  4. Spatio-Temporal Super-Resolution Reconstruction of Remote-Sensing Images Based on Adaptive Multi-Scale Detail Enhancement.

    Science.gov (United States)

    Zhu, Hong; Tang, Xinming; Xie, Junfeng; Song, Weidong; Mo, Fan; Gao, Xiaoming

    2018-02-07

    There are many problems in existing reconstruction-based super-resolution algorithms, such as the lack of texture-feature representation and of high-frequency details. Multi-scale detail enhancement can produce more texture information and high-frequency information. Therefore, super-resolution reconstruction of remote-sensing images based on adaptive multi-scale detail enhancement (AMDE-SR) is proposed in this paper. First, the information entropy of each remote-sensing image is calculated, and the image with the maximum entropy value is regarded as the reference image. Subsequently, spatio-temporal remote-sensing images are processed using phase normalization, which is to reduce the time phase difference of image data and enhance the complementarity of information. The multi-scale image information is then decomposed using the L ₀ gradient minimization model, and the non-redundant information is processed by difference calculation and expanding non-redundant layers and the redundant layer by the iterative back-projection (IBP) technique. The different-scale non-redundant information is adaptive-weighted and fused using cross-entropy. Finally, a nonlinear texture-detail-enhancement function is built to improve the scope of small details, and the peak signal-to-noise ratio (PSNR) is used as an iterative constraint. Ultimately, high-resolution remote-sensing images with abundant texture information are obtained by iterative optimization. Real results show an average gain in entropy of up to 0.42 dB for an up-scaling of 2 and a significant promotion gain in enhancement measure evaluation for an up-scaling of 2. The experimental results show that the performance of the AMED-SR method is better than existing super-resolution reconstruction methods in terms of visual and accuracy improvements.

  5. Spatio-Temporal Super-Resolution Reconstruction of Remote-Sensing Images Based on Adaptive Multi-Scale Detail Enhancement

    Science.gov (United States)

    Zhu, Hong; Tang, Xinming; Xie, Junfeng; Song, Weidong; Mo, Fan; Gao, Xiaoming

    2018-01-01

    There are many problems in existing reconstruction-based super-resolution algorithms, such as the lack of texture-feature representation and of high-frequency details. Multi-scale detail enhancement can produce more texture information and high-frequency information. Therefore, super-resolution reconstruction of remote-sensing images based on adaptive multi-scale detail enhancement (AMDE-SR) is proposed in this paper. First, the information entropy of each remote-sensing image is calculated, and the image with the maximum entropy value is regarded as the reference image. Subsequently, spatio-temporal remote-sensing images are processed using phase normalization, which is to reduce the time phase difference of image data and enhance the complementarity of information. The multi-scale image information is then decomposed using the L0 gradient minimization model, and the non-redundant information is processed by difference calculation and expanding non-redundant layers and the redundant layer by the iterative back-projection (IBP) technique. The different-scale non-redundant information is adaptive-weighted and fused using cross-entropy. Finally, a nonlinear texture-detail-enhancement function is built to improve the scope of small details, and the peak signal-to-noise ratio (PSNR) is used as an iterative constraint. Ultimately, high-resolution remote-sensing images with abundant texture information are obtained by iterative optimization. Real results show an average gain in entropy of up to 0.42 dB for an up-scaling of 2 and a significant promotion gain in enhancement measure evaluation for an up-scaling of 2. The experimental results show that the performance of the AMED-SR method is better than existing super-resolution reconstruction methods in terms of visual and accuracy improvements. PMID:29414893

  6. Factors influencing detail detectability in radiologic imaging

    International Nuclear Information System (INIS)

    Gurvich, A.M.

    1985-01-01

    The detectability of various details is estimated quantitatively from the essential technical parameters of the imaging system and additional influencing factors including viewing of the image. The analysis implies the formation of the input radiation distribution (contrast formation, influence of kVp). Noise, image contrast (gamma), modulation transfer function and contrast threshold of the observer are of different influence on details of different size. Thus further optimization of imaging systems and their adaption to specific imaging tasks are facilitated

  7. Real-time 3D imaging methods using 2D phased arrays based on synthetic focusing techniques.

    Science.gov (United States)

    Kim, Jung-Jun; Song, Tai-Kyong

    2008-07-01

    A fast 3D ultrasound imaging technique using a 2D phased array transducer based on the synthetic focusing method for nondestructive testing or medical imaging is proposed. In the proposed method, each column of a 2D array is fired successively to produce transverse fan beams focused at a fixed depth along a given longitudinal direction and the resulting pulse echoes are received at all elements of a 2D array used. After firing all column arrays, a frame of high-resolution image along a given longitudinal direction is obtained with dynamic focusing employed in the longitudinal direction on receive and in the transverse direction on both transmit and receive. The volume rate of the proposed method can be increased much higher than that of the conventional 2D array imaging by employing an efficient sparse array technique. A simple modification to the proposed method can further increase the volume scan rate significantly. The proposed methods are verified through computer simulations.

  8. Head pose estimation from a 2D face image using 3D face morphing with depth parameters.

    Science.gov (United States)

    Kong, Seong G; Mbouna, Ralph Oyini

    2015-06-01

    This paper presents estimation of head pose angles from a single 2D face image using a 3D face model morphed from a reference face model. A reference model refers to a 3D face of a person of the same ethnicity and gender as the query subject. The proposed scheme minimizes the disparity between the two sets of prominent facial features on the query face image and the corresponding points on the 3D face model to estimate the head pose angles. The 3D face model used is morphed from a reference model to be more specific to the query face in terms of the depth error at the feature points. The morphing process produces a 3D face model more specific to the query image when multiple 2D face images of the query subject are available for training. The proposed morphing process is computationally efficient since the depth of a 3D face model is adjusted by a scalar depth parameter at feature points. Optimal depth parameters are found by minimizing the disparity between the 2D features of the query face image and the corresponding features on the morphed 3D model projected onto 2D space. The proposed head pose estimation technique was evaluated on two benchmarking databases: 1) the USF Human-ID database for depth estimation and 2) the Pointing'04 database for head pose estimation. Experiment results demonstrate that head pose estimation errors in nodding and shaking angles are as low as 7.93° and 4.65° on average for a single 2D input face image.

  9. MLESAC Based Localization of Needle Insertion Using 2D Ultrasound Images

    Science.gov (United States)

    Xu, Fei; Gao, Dedong; Wang, Shan; Zhanwen, A.

    2018-04-01

    In the 2D ultrasound image of ultrasound-guided percutaneous needle insertions, it is difficult to determine the positions of needle axis and tip because of the existence of artifacts and other noises. In this work the speckle is regarded as the noise of an ultrasound image, and a novel algorithm is presented to detect the needle in a 2D ultrasound image. Firstly, the wavelet soft thresholding technique based on BayesShrink rule is used to denoise the speckle of ultrasound image. Secondly, we add Otsu’s thresholding method and morphologic operations to pre-process the ultrasound image. Finally, the localization of the needle is identified and positioned in the 2D ultrasound image based on the maximum likelihood estimation sample consensus (MLESAC) algorithm. The experimental results show that it is valid for estimating the position of needle axis and tip in the ultrasound images with the proposed algorithm. The research work is hopeful to be used in the path planning and robot-assisted needle insertion procedures.

  10. Security of Color Image Data Designed by Public-Key Cryptosystem Associated with 2D-DWT

    Science.gov (United States)

    Mishra, D. C.; Sharma, R. K.; Kumar, Manish; Kumar, Kuldeep

    2014-08-01

    In present times the security of image data is a major issue. So, we have proposed a novel technique for security of color image data by public-key cryptosystem or asymmetric cryptosystem. In this technique, we have developed security of color image data using RSA (Rivest-Shamir-Adleman) cryptosystem with two-dimensional discrete wavelet transform (2D-DWT). Earlier proposed schemes for security of color images designed on the basis of keys, but this approach provides security of color images with the help of keys and correct arrangement of RSA parameters. If the attacker knows about exact keys, but has no information of exact arrangement of RSA parameters, then the original information cannot be recovered from the encrypted data. Computer simulation based on standard example is critically examining the behavior of the proposed technique. Security analysis and a detailed comparison between earlier developed schemes for security of color images and proposed technique are also mentioned for the robustness of the cryptosystem.

  11. A new automated assessment method for contrast-detail images by applying support vector machine and its robustness to nonlinear image processing.

    Science.gov (United States)

    Takei, Takaaki; Ikeda, Mitsuru; Imai, Kuniharu; Yamauchi-Kawaura, Chiyo; Kato, Katsuhiko; Isoda, Haruo

    2013-09-01

    The automated contrast-detail (C-D) analysis methods developed so-far cannot be expected to work well on images processed with nonlinear methods, such as noise reduction methods. Therefore, we have devised a new automated C-D analysis method by applying support vector machine (SVM), and tested for its robustness to nonlinear image processing. We acquired the CDRAD (a commercially available C-D test object) images at a tube voltage of 120 kV and a milliampere-second product (mAs) of 0.5-5.0. A partial diffusion equation based technique was used as noise reduction method. Three radiologists and three university students participated in the observer performance study. The training data for our SVM method was the classification data scored by the one radiologist for the CDRAD images acquired at 1.6 and 3.2 mAs and their noise-reduced images. We also compared the performance of our SVM method with the CDRAD Analyser algorithm. The mean C-D diagrams (that is a plot of the mean of the smallest visible hole diameter vs. hole depth) obtained from our devised SVM method agreed well with the ones averaged across the six human observers for both original and noise-reduced CDRAD images, whereas the mean C-D diagrams from the CDRAD Analyser algorithm disagreed with the ones from the human observers for both original and noise-reduced CDRAD images. In conclusion, our proposed SVM method for C-D analysis will work well for the images processed with the non-linear noise reduction method as well as for the original radiographic images.

  12. Toward 2D and 3D imaging of magnetic nanoparticles using EPR measurements.

    Science.gov (United States)

    Coene, A; Crevecoeur, G; Leliaert, J; Dupré, L

    2015-09-01

    Magnetic nanoparticles (MNPs) are an important asset in many biomedical applications. An effective working of these applications requires an accurate knowledge of the spatial MNP distribution. A promising, noninvasive, and sensitive technique to visualize MNP distributions in vivo is electron paramagnetic resonance (EPR). Currently only 1D MNP distributions can be reconstructed. In this paper, the authors propose extending 1D EPR toward 2D and 3D using computer simulations to allow accurate imaging of MNP distributions. To find the MNP distribution belonging to EPR measurements, an inverse problem needs to be solved. The solution of this inverse problem highly depends on the stability of the inverse problem. The authors adapt 1D EPR imaging to realize the imaging of multidimensional MNP distributions. Furthermore, the authors introduce partial volume excitation in which only parts of the volume are imaged to increase stability of the inverse solution and to speed up the measurements. The authors simulate EPR measurements of different 2D and 3D MNP distributions and solve the inverse problem. The stability is evaluated by calculating the condition measure and by comparing the actual MNP distribution to the reconstructed MNP distribution. Based on these simulations, the authors define requirements for the EPR system to cope with the added dimensions. Moreover, the authors investigate how EPR measurements should be conducted to improve the stability of the associated inverse problem and to increase reconstruction quality. The approach used in 1D EPR can only be employed for the reconstruction of small volumes in 2D and 3D EPRs due to numerical instability of the inverse solution. The authors performed EPR measurements of increasing cylindrical volumes and evaluated the condition measure. This showed that a reduction of the inherent symmetry in the EPR methodology is necessary. By reducing the symmetry of the EPR setup, quantitative images of larger volumes can be

  13. Toward 2D and 3D imaging of magnetic nanoparticles using EPR measurements

    International Nuclear Information System (INIS)

    Coene, A.; Crevecoeur, G.; Dupré, L.; Leliaert, J.

    2015-01-01

    Purpose: Magnetic nanoparticles (MNPs) are an important asset in many biomedical applications. An effective working of these applications requires an accurate knowledge of the spatial MNP distribution. A promising, noninvasive, and sensitive technique to visualize MNP distributions in vivo is electron paramagnetic resonance (EPR). Currently only 1D MNP distributions can be reconstructed. In this paper, the authors propose extending 1D EPR toward 2D and 3D using computer simulations to allow accurate imaging of MNP distributions. Methods: To find the MNP distribution belonging to EPR measurements, an inverse problem needs to be solved. The solution of this inverse problem highly depends on the stability of the inverse problem. The authors adapt 1D EPR imaging to realize the imaging of multidimensional MNP distributions. Furthermore, the authors introduce partial volume excitation in which only parts of the volume are imaged to increase stability of the inverse solution and to speed up the measurements. The authors simulate EPR measurements of different 2D and 3D MNP distributions and solve the inverse problem. The stability is evaluated by calculating the condition measure and by comparing the actual MNP distribution to the reconstructed MNP distribution. Based on these simulations, the authors define requirements for the EPR system to cope with the added dimensions. Moreover, the authors investigate how EPR measurements should be conducted to improve the stability of the associated inverse problem and to increase reconstruction quality. Results: The approach used in 1D EPR can only be employed for the reconstruction of small volumes in 2D and 3D EPRs due to numerical instability of the inverse solution. The authors performed EPR measurements of increasing cylindrical volumes and evaluated the condition measure. This showed that a reduction of the inherent symmetry in the EPR methodology is necessary. By reducing the symmetry of the EPR setup, quantitative images of

  14. Efficient 2-D DCT Computation from an Image Representation Point of View

    OpenAIRE

    Papakostas, G.A.; Koulouriotis, D.E.; Karakasis, E.G.

    2009-01-01

    A novel methodology that ensures the computation of 2-D DCT coefficients in gray-scale images as well as in binary ones, with high computation rates, was presented in the previous sections. Through a new image representation scheme, called ISR (Image Slice Representation) the 2-D DCT coefficients can be computed in significantly reduced time, with the same accuracy.

  15. Color image enhancement of medical images using alpha-rooting and zonal alpha-rooting methods on 2D QDFT

    Science.gov (United States)

    Grigoryan, Artyom M.; John, Aparna; Agaian, Sos S.

    2017-03-01

    2-D quaternion discrete Fourier transform (2-D QDFT) is the Fourier transform applied to color images when the color images are considered in the quaternion space. The quaternion numbers are four dimensional hyper-complex numbers. Quaternion representation of color image allows us to see the color of the image as a single unit. In quaternion approach of color image enhancement, each color is seen as a vector. This permits us to see the merging effect of the color due to the combination of the primary colors. The color images are used to be processed by applying the respective algorithm onto each channels separately, and then, composing the color image from the processed channels. In this article, the alpha-rooting and zonal alpha-rooting methods are used with the 2-D QDFT. In the alpha-rooting method, the alpha-root of the transformed frequency values of the 2-D QDFT are determined before taking the inverse transform. In the zonal alpha-rooting method, the frequency spectrum of the 2-D QDFT is divided by different zones and the alpha-rooting is applied with different alpha values for different zones. The optimization of the choice of alpha values is done with the genetic algorithm. The visual perception of 3-D medical images is increased by changing the reference gray line.

  16. 124I-Epidepride: A PET radiotracer for extended imaging of dopamine D2/D3 receptors

    International Nuclear Information System (INIS)

    Pandey, Suresh; Venugopal, Archana; Kant, Ritu; Coleman, Robert; Mukherjee, Jogeshwar

    2014-01-01

    Objectives: A new radiotracer, 124 I-epidepride, has been developed for the imaging of dopamine D2/3 receptors (D2/3Rs). 124 I-Epidepride (half-life of 124 I = 4.2 days) allows imaging over extended periods compared to 18 F-fallypride (half-life of 18 F = 0.076 days) and may maximize visualization of D2/3Rs in the brain and pancreas (allowing clearance from adjacent organs). D2/3Rs are also present in pancreatic islets where they co-localize with insulin to produce granules and may serve as a surrogate marker for imaging diabetes. Methods: 124 I-Epidepride was synthesized using N-[[(2S)-1-ethylpyrrolidin-2-yl]methyl]-5-tributyltin-2, 3-dimethoxybenzamide and 124 I-iodide under no carrier added condition. Rats were used for in vitro and in vivo imaging. Brain slices were incubated with 124 I-epidepride (0.75 μCi/cc) and nonspecific binding measured with 10 μM haloperidol. Autoradiograms were analyzed by OptiQuant. 124 I-Epidepride (0.2 to 0.3 mCi, iv) was administered to rats and brain uptake at 3 hours, 24 hours, and 48 hours post injection was evaluated. Results: 124 I-Epidepride was obtained with 50% radiochemical yield and high radiochemical purity (> 95%). 124 I-Epidepride localized in the striatum with a striatum to cerebellum ratio of 10. Binding was displaced by dopamine and haloperidol. Brain slices demonstrated localization of 124 I-epidepride up until 48 hours in the striatum. However, the extent of binding was reduced significantly. Conclusions: 124 I-Epidepride is a new radiotracer suitable for extended imaging of dopamine D2/3 receptors and may have applications in imaging of receptors in the brain and monitoring pancreatic islet cell grafting

  17. High-performance GPU-based rendering for real-time, rigid 2D/3D-image registration and motion prediction in radiation oncology.

    Science.gov (United States)

    Spoerk, Jakob; Gendrin, Christelle; Weber, Christoph; Figl, Michael; Pawiro, Supriyanto Ardjo; Furtado, Hugo; Fabri, Daniella; Bloch, Christoph; Bergmann, Helmar; Gröller, Eduard; Birkfellner, Wolfgang

    2012-02-01

    A common problem in image-guided radiation therapy (IGRT) of lung cancer as well as other malignant diseases is the compensation of periodic and aperiodic motion during dose delivery. Modern systems for image-guided radiation oncology allow for the acquisition of cone-beam computed tomography data in the treatment room as well as the acquisition of planar radiographs during the treatment. A mid-term research goal is the compensation of tumor target volume motion by 2D/3D Registration. In 2D/3D registration, spatial information on organ location is derived by an iterative comparison of perspective volume renderings, so-called digitally rendered radiographs (DRR) from computed tomography volume data, and planar reference x-rays. Currently, this rendering process is very time consuming, and real-time registration, which should at least provide data on organ position in less than a second, has not come into existence. We present two GPU-based rendering algorithms which generate a DRR of 512×512 pixels size from a CT dataset of 53 MB size at a pace of almost 100 Hz. This rendering rate is feasible by applying a number of algorithmic simplifications which range from alternative volume-driven rendering approaches - namely so-called wobbled splatting - to sub-sampling of the DRR-image by means of specialized raycasting techniques. Furthermore, general purpose graphics processing unit (GPGPU) programming paradigms were consequently utilized. Rendering quality and performance as well as the influence on the quality and performance of the overall registration process were measured and analyzed in detail. The results show that both methods are competitive and pave the way for fast motion compensation by rigid and possibly even non-rigid 2D/3D registration and, beyond that, adaptive filtering of motion models in IGRT. Copyright © 2011. Published by Elsevier GmbH.

  18. High-performance GPU-based rendering for real-time, rigid 2D/3D-image registration and motion prediction in radiation oncology

    Energy Technology Data Exchange (ETDEWEB)

    Spoerk, Jakob; Gendrin, Christelle; Weber, Christoph [Medical University of Vienna (Austria). Center of Medical Physics and Biomedical Engineering] [and others

    2012-07-01

    A common problem in image-guided radiation therapy (IGRT) of lung cancer as well as other malignant diseases is the compensation of periodic and aperiodic motion during dose delivery. Modern systems for image-guided radiation oncology allow for the acquisition of cone-beam computed tomography data in the treatment room as well as the acquisition of planar radiographs during the treatment. A mid-term research goal is the compensation of tumor target volume motion by 2D/3D Registration. In 2D/3D registration, spatial information on organ location is derived by an iterative comparison of perspective volume renderings, so-called digitally rendered radiographs (DRR) from computed tomography volume data, and planar reference X-rays. Currently, this rendering process is very time consuming, and real-time registration, which should at least provide data on organ position in less than a second, has not come into existence. We present two GPU-based rendering algorithms which generate a DRR of 512 x 512 pixels size from a CT dataset of 53 MB size at a pace of almost 100 Hz. This rendering rate is feasible by applying a number of algorithmic simplifications which range from alternative volume-driven rendering approaches - namely so-called wobbled splatting - to sub-sampling of the DRR-image by means of specialized raycasting techniques. Furthermore, general purpose graphics processing unit (GPGPU) programming paradigms were consequently utilized. Rendering quality and performance as well as the influence on the quality and performance of the overall registration process were measured and analyzed in detail. The results show that both methods are competitive and pave the way for fast motion compensation by rigid and possibly even non-rigid 2D/3D registration and, beyond that, adaptive filtering of motion models in IGRT. (orig.)

  19. Sampling Number Effects in 2D and Range Imaging of Range-gated Acquisition

    International Nuclear Information System (INIS)

    Kwon, Seong-Ouk; Park, Seung-Kyu; Baik, Sung-Hoon; Cho, Jai-Wan; Jeong, Kyung-Min

    2015-01-01

    In this paper, we analyzed the number effects of sampling images for making a 2D image and a range image from acquired RGI images. We analyzed the number effects of RGI images for making a 2D image and a range image using a RGI vision system. As the results, 2D image quality was not much depended on the number of sampling images but on how much well extract efficient RGI images. But, the number of RGI images was important for making a range image because range image quality was proportional to the number of RGI images. Image acquiring in a monitoring area of nuclear industry is an important function for safety inspection and preparing appropriate control plans. To overcome the non-visualization problem caused by airborne obstacle particles, vision systems should have extra-functions, such as active illumination lightening through disturbance airborne particles. One of these powerful active vision systems is a range-gated imaging system. The vision system based on the range-gated imaging system can acquire image data from raining or smoking environments. Range-gated imaging (RGI) is a direct active visualization technique using a highly sensitive image sensor and a high intensity illuminant. Currently, the range-gated imaging technique providing 2D and 3D images is one of emerging active vision technologies. The range-gated imaging system gets vision information by summing time sliced vision images. In the RGI system, a high intensity illuminant illuminates for ultra-short time and a highly sensitive image sensor is gated by ultra-short exposure time to only get the illumination light. Here, the illuminant illuminates objects by flashing strong light through airborne disturbance particles. Thus, in contrast to passive conventional vision systems, the RGI active vision technology robust for low-visibility environments

  20. Sampling Number Effects in 2D and Range Imaging of Range-gated Acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Seong-Ouk; Park, Seung-Kyu; Baik, Sung-Hoon; Cho, Jai-Wan; Jeong, Kyung-Min [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In this paper, we analyzed the number effects of sampling images for making a 2D image and a range image from acquired RGI images. We analyzed the number effects of RGI images for making a 2D image and a range image using a RGI vision system. As the results, 2D image quality was not much depended on the number of sampling images but on how much well extract efficient RGI images. But, the number of RGI images was important for making a range image because range image quality was proportional to the number of RGI images. Image acquiring in a monitoring area of nuclear industry is an important function for safety inspection and preparing appropriate control plans. To overcome the non-visualization problem caused by airborne obstacle particles, vision systems should have extra-functions, such as active illumination lightening through disturbance airborne particles. One of these powerful active vision systems is a range-gated imaging system. The vision system based on the range-gated imaging system can acquire image data from raining or smoking environments. Range-gated imaging (RGI) is a direct active visualization technique using a highly sensitive image sensor and a high intensity illuminant. Currently, the range-gated imaging technique providing 2D and 3D images is one of emerging active vision technologies. The range-gated imaging system gets vision information by summing time sliced vision images. In the RGI system, a high intensity illuminant illuminates for ultra-short time and a highly sensitive image sensor is gated by ultra-short exposure time to only get the illumination light. Here, the illuminant illuminates objects by flashing strong light through airborne disturbance particles. Thus, in contrast to passive conventional vision systems, the RGI active vision technology robust for low-visibility environments.

  1. A new automated assessment method for contrast–detail images by applying support vector machine and its robustness to nonlinear image processing

    International Nuclear Information System (INIS)

    Takei, Takaaki; Ikeda, Mitsuru; Imai, Kumiharu; Yamauchi-Kawaura, Chiyo; Kato, Katsuhiko; Isoda, Haruo

    2013-01-01

    The automated contrast–detail (C–D) analysis methods developed so-far cannot be expected to work well on images processed with nonlinear methods, such as noise reduction methods. Therefore, we have devised a new automated C–D analysis method by applying support vector machine (SVM), and tested for its robustness to nonlinear image processing. We acquired the CDRAD (a commercially available C–D test object) images at a tube voltage of 120 kV and a milliampere-second product (mAs) of 0.5–5.0. A partial diffusion equation based technique was used as noise reduction method. Three radiologists and three university students participated in the observer performance study. The training data for our SVM method was the classification data scored by the one radiologist for the CDRAD images acquired at 1.6 and 3.2 mAs and their noise-reduced images. We also compared the performance of our SVM method with the CDRAD Analyser algorithm. The mean C–D diagrams (that is a plot of the mean of the smallest visible hole diameter vs. hole depth) obtained from our devised SVM method agreed well with the ones averaged across the six human observers for both original and noise-reduced CDRAD images, whereas the mean C–D diagrams from the CDRAD Analyser algorithm disagreed with the ones from the human observers for both original and noise-reduced CDRAD images. In conclusion, our proposed SVM method for C–D analysis will work well for the images processed with the non-linear noise reduction method as well as for the original radiographic images.

  2. Algebraic 2D PET image reconstruction using depth-of-interaction information

    International Nuclear Information System (INIS)

    Yamaya, Taiga; Obi, Takashi; Yamaguchi, Masahiro; Kita, Kouichi

    2001-01-01

    Recently a high-performance PET scanner, which measures depth-of-interaction (DOI) information, is being developed for molecular imaging. DOI measurement of multi-layered thin crystals can improve spatial resolution and scanner sensitivity simultaneously. In this paper, we apply an algebraic image reconstruction method to 2-dimensional (2D) DOI-PET scanners using accurate system modeling, in order to evaluate the effects of using DOI information on PET image quality. Algebraic image reconstruction methods have been successfully used to improve PET image quality, compared with the conventional filtered backprojection method. The proposed method is applied to simulated data for a small 2D DOI-PET scanner. The results show that accurate system modeling improves spatial resolution without noise emphasis, and that DOI information improves uniformity of spatial resolution. (author)

  3. Development and Performance Evaluation of Image-Based Robotic Waxing System for Detailing Automobiles.

    Science.gov (United States)

    Lin, Chi-Ying; Hsu, Bing-Cheng

    2018-05-14

    Waxing is an important aspect of automobile detailing, aimed at protecting the finish of the car and preventing rust. At present, this delicate work is conducted manually due to the need for iterative adjustments to achieve acceptable quality. This paper presents a robotic waxing system in which surface images are used to evaluate the quality of the finish. An RGB-D camera is used to build a point cloud that details the sheet metal components to enable path planning for a robot manipulator. The robot is equipped with a multi-axis force sensor to measure and control the forces involved in the application and buffing of wax. Images of sheet metal components that were waxed by experienced car detailers were analyzed using image processing algorithms. A Gaussian distribution function and its parameterized values were obtained from the images for use as a performance criterion in evaluating the quality of surfaces prepared by the robotic waxing system. Waxing force and dwell time were optimized using a mathematical model based on the image-based criterion used to measure waxing performance. Experimental results demonstrate the feasibility of the proposed robotic waxing system and image-based performance evaluation scheme.

  4. Image denoising by sparse 3-D transform-domain collaborative filtering.

    Science.gov (United States)

    Dabov, Kostadin; Foi, Alessandro; Katkovnik, Vladimir; Egiazarian, Karen

    2007-08-01

    We propose a novel image denoising strategy based on an enhanced sparse representation in transform domain. The enhancement of the sparsity is achieved by grouping similar 2-D image fragments (e.g., blocks) into 3-D data arrays which we call "groups." Collaborative filtering is a special procedure developed to deal with these 3-D groups. We realize it using the three successive steps: 3-D transformation of a group, shrinkage of the transform spectrum, and inverse 3-D transformation. The result is a 3-D estimate that consists of the jointly filtered grouped image blocks. By attenuating the noise, the collaborative filtering reveals even the finest details shared by grouped blocks and, at the same time, it preserves the essential unique features of each individual block. The filtered blocks are then returned to their original positions. Because these blocks are overlapping, for each pixel, we obtain many different estimates which need to be combined. Aggregation is a particular averaging procedure which is exploited to take advantage of this redundancy. A significant improvement is obtained by a specially developed collaborative Wiener filtering. An algorithm based on this novel denoising strategy and its efficient implementation are presented in full detail; an extension to color-image denoising is also developed. The experimental results demonstrate that this computationally scalable algorithm achieves state-of-the-art denoising performance in terms of both peak signal-to-noise ratio and subjective visual quality.

  5. AN IMAGE-BASED TECHNIQUE FOR 3D BUILDING RECONSTRUCTION USING MULTI-VIEW UAV IMAGES

    Directory of Open Access Journals (Sweden)

    F. Alidoost

    2015-12-01

    Full Text Available Nowadays, with the development of the urban areas, the automatic reconstruction of the buildings, as an important objects of the city complex structures, became a challenging topic in computer vision and photogrammetric researches. In this paper, the capability of multi-view Unmanned Aerial Vehicles (UAVs images is examined to provide a 3D model of complex building façades using an efficient image-based modelling workflow. The main steps of this work include: pose estimation, point cloud generation, and 3D modelling. After improving the initial values of interior and exterior parameters at first step, an efficient image matching technique such as Semi Global Matching (SGM is applied on UAV images and a dense point cloud is generated. Then, a mesh model of points is calculated using Delaunay 2.5D triangulation and refined to obtain an accurate model of building. Finally, a texture is assigned to mesh in order to create a realistic 3D model. The resulting model has provided enough details of building based on visual assessment.

  6. 2D Tsallis Entropy for Image Segmentation Based on Modified Chaotic Bat Algorithm

    Directory of Open Access Journals (Sweden)

    Zhiwei Ye

    2018-03-01

    Full Text Available Image segmentation is a significant step in image analysis and computer vision. Many entropy based approaches have been presented in this topic; among them, Tsallis entropy is one of the best performing methods. However, 1D Tsallis entropy does not consider make use of the spatial correlation information within the neighborhood results might be ruined by noise. Therefore, 2D Tsallis entropy is proposed to solve the problem, and results are compared with 1D Fisher, 1D maximum entropy, 1D cross entropy, 1D Tsallis entropy, fuzzy entropy, 2D Fisher, 2D maximum entropy and 2D cross entropy. On the other hand, due to the existence of huge computational costs, meta-heuristics algorithms like genetic algorithm (GA, particle swarm optimization (PSO, ant colony optimization algorithm (ACO and differential evolution algorithm (DE are used to accelerate the 2D Tsallis entropy thresholding method. In this paper, considering 2D Tsallis entropy as a constrained optimization problem, the optimal thresholds are acquired by maximizing the objective function using a modified chaotic Bat algorithm (MCBA. The proposed algorithm has been tested on some actual and infrared images. The results are compared with that of PSO, GA, ACO and DE and demonstrate that the proposed method outperforms other approaches involved in the paper, which is a feasible and effective option for image segmentation.

  7. How does c-view image quality compare with conventional 2D FFDM?

    Science.gov (United States)

    Nelson, Jeffrey S; Wells, Jered R; Baker, Jay A; Samei, Ehsan

    2016-05-01

    The FDA approved the use of digital breast tomosynthesis (DBT) in 2011 as an adjunct to 2D full field digital mammography (FFDM) with the constraint that all DBT acquisitions must be paired with a 2D image to assure adequate interpretative information is provided. Recently manufacturers have developed methods to provide a synthesized 2D image generated from the DBT data with the hope of sparing patients the radiation exposure from the FFDM acquisition. While this much needed alternative effectively reduces the total radiation burden, differences in image quality must also be considered. The goal of this study was to compare the intrinsic image quality of synthesized 2D c-view and 2D FFDM images in terms of resolution, contrast, and noise. Two phantoms were utilized in this study: the American College of Radiology mammography accreditation phantom (ACR phantom) and a novel 3D printed anthropomorphic breast phantom. Both phantoms were imaged using a Hologic Selenia Dimensions 3D system. Analysis of the ACR phantom includes both visual inspection and objective automated analysis using in-house software. Analysis of the 3D anthropomorphic phantom includes visual assessment of resolution and Fourier analysis of the noise. Using ACR-defined scoring criteria for the ACR phantom, the FFDM images scored statistically higher than c-view according to both the average observer and automated scores. In addition, between 50% and 70% of c-view images failed to meet the nominal minimum ACR accreditation requirements-primarily due to fiber breaks. Software analysis demonstrated that c-view provided enhanced visualization of medium and large microcalcification objects; however, the benefits diminished for smaller high contrast objects and all low contrast objects. Visual analysis of the anthropomorphic phantom showed a measureable loss of resolution in the c-view image (11 lp/mm FFDM, 5 lp/mm c-view) and loss in detection of small microcalcification objects. Spectral analysis of the

  8. How does C-VIEW image quality compare with conventional 2D FFDM?

    International Nuclear Information System (INIS)

    Nelson, Jeffrey S.; Wells, Jered R.; Baker, Jay A.; Samei, Ehsan

    2016-01-01

    Purpose: The FDA approved the use of digital breast tomosynthesis (DBT) in 2011 as an adjunct to 2D full field digital mammography (FFDM) with the constraint that all DBT acquisitions must be paired with a 2D image to assure adequate interpretative information is provided. Recently manufacturers have developed methods to provide a synthesized 2D image generated from the DBT data with the hope of sparing patients the radiation exposure from the FFDM acquisition. While this much needed alternative effectively reduces the total radiation burden, differences in image quality must also be considered. The goal of this study was to compare the intrinsic image quality of synthesized 2D C-VIEW and 2D FFDM images in terms of resolution, contrast, and noise. Methods: Two phantoms were utilized in this study: the American College of Radiology mammography accreditation phantom (ACR phantom) and a novel 3D printed anthropomorphic breast phantom. Both phantoms were imaged using a Hologic Selenia Dimensions 3D system. Analysis of the ACR phantom includes both visual inspection and objective automated analysis using in-house software. Analysis of the 3D anthropomorphic phantom includes visual assessment of resolution and Fourier analysis of the noise. Results: Using ACR-defined scoring criteria for the ACR phantom, the FFDM images scored statistically higher than C-VIEW according to both the average observer and automated scores. In addition, between 50% and 70% of C-VIEW images failed to meet the nominal minimum ACR accreditation requirements—primarily due to fiber breaks. Software analysis demonstrated that C-VIEW provided enhanced visualization of medium and large microcalcification objects; however, the benefits diminished for smaller high contrast objects and all low contrast objects. Visual analysis of the anthropomorphic phantom showed a measureable loss of resolution in the C-VIEW image (11 lp/mm FFDM, 5 lp/mm C-VIEW) and loss in detection of small microcalcification

  9. How does C-VIEW image quality compare with conventional 2D FFDM?

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Jeffrey S., E-mail: nelson.jeffrey@duke.edu; Wells, Jered R. [Department of Radiology, Clinical Imaging Physics Group, Duke University Medical Center, Durham, North Carolina 27705 (United States); Baker, Jay A. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Samei, Ehsan [Department of Radiology, Clinical Imaging Physics Group, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Departments of Biomedical Engineering and Electrical and Computer Engineering, Pratt School of Engineering, Duke University, Durham, North Carolina 27705 (United States)

    2016-05-15

    Purpose: The FDA approved the use of digital breast tomosynthesis (DBT) in 2011 as an adjunct to 2D full field digital mammography (FFDM) with the constraint that all DBT acquisitions must be paired with a 2D image to assure adequate interpretative information is provided. Recently manufacturers have developed methods to provide a synthesized 2D image generated from the DBT data with the hope of sparing patients the radiation exposure from the FFDM acquisition. While this much needed alternative effectively reduces the total radiation burden, differences in image quality must also be considered. The goal of this study was to compare the intrinsic image quality of synthesized 2D C-VIEW and 2D FFDM images in terms of resolution, contrast, and noise. Methods: Two phantoms were utilized in this study: the American College of Radiology mammography accreditation phantom (ACR phantom) and a novel 3D printed anthropomorphic breast phantom. Both phantoms were imaged using a Hologic Selenia Dimensions 3D system. Analysis of the ACR phantom includes both visual inspection and objective automated analysis using in-house software. Analysis of the 3D anthropomorphic phantom includes visual assessment of resolution and Fourier analysis of the noise. Results: Using ACR-defined scoring criteria for the ACR phantom, the FFDM images scored statistically higher than C-VIEW according to both the average observer and automated scores. In addition, between 50% and 70% of C-VIEW images failed to meet the nominal minimum ACR accreditation requirements—primarily due to fiber breaks. Software analysis demonstrated that C-VIEW provided enhanced visualization of medium and large microcalcification objects; however, the benefits diminished for smaller high contrast objects and all low contrast objects. Visual analysis of the anthropomorphic phantom showed a measureable loss of resolution in the C-VIEW image (11 lp/mm FFDM, 5 lp/mm C-VIEW) and loss in detection of small microcalcification

  10. Position tracking of moving liver lesion based on real-time registration between 2D ultrasound and 3D preoperative images

    International Nuclear Information System (INIS)

    Weon, Chijun; Hyun Nam, Woo; Lee, Duhgoon; Ra, Jong Beom; Lee, Jae Young

    2015-01-01

    Purpose: Registration between 2D ultrasound (US) and 3D preoperative magnetic resonance (MR) (or computed tomography, CT) images has been studied recently for US-guided intervention. However, the existing techniques have some limits, either in the registration speed or the performance. The purpose of this work is to develop a real-time and fully automatic registration system between two intermodal images of the liver, and subsequently an indirect lesion positioning/tracking algorithm based on the registration result, for image-guided interventions. Methods: The proposed position tracking system consists of three stages. In the preoperative stage, the authors acquire several 3D preoperative MR (or CT) images at different respiratory phases. Based on the transformations obtained from nonrigid registration of the acquired 3D images, they then generate a 4D preoperative image along the respiratory phase. In the intraoperative preparatory stage, they properly attach a 3D US transducer to the patient’s body and fix its pose using a holding mechanism. They then acquire a couple of respiratory-controlled 3D US images. Via the rigid registration of these US images to the 3D preoperative images in the 4D image, the pose information of the fixed-pose 3D US transducer is determined with respect to the preoperative image coordinates. As feature(s) to use for the rigid registration, they may choose either internal liver vessels or the inferior vena cava. Since the latter is especially useful in patients with a diffuse liver disease, the authors newly propose using it. In the intraoperative real-time stage, they acquire 2D US images in real-time from the fixed-pose transducer. For each US image, they select candidates for its corresponding 2D preoperative slice from the 4D preoperative MR (or CT) image, based on the predetermined pose information of the transducer. The correct corresponding image is then found among those candidates via real-time 2D registration based on a

  11. High-resolution mapping of 1D and 2D dose distributions using X-band electron paramagnetic resonance imaging

    International Nuclear Information System (INIS)

    Kolbun, N.; Lund, E.; Adolfsson, E.; Gustafsson, H.

    2014-01-01

    Electron paramagnetic resonance imaging (EPRI) was performed to visualise 2D dose distributions of homogeneously irradiated potassium dithionate tablets and to demonstrate determination of 1D dose profiles along the height of the tablets. Mathematical correction was applied for each relative dose profile in order to take into account the inhomogeneous response of the resonator using X-band EPRI. The dose profiles are presented with the spatial resolution of 0.6 mm from the acquired 2D images; this value is limited by pixel size, and 1D dose profiles from 1D imaging with spatial resolution of 0.3 mm limited by the intrinsic line-width of potassium dithionate. In this paper, dose profiles from 2D reconstructed electron paramagnetic resonance (EPR) images using the Xepr software package by Bruker are focussed. The conclusion is that using potassium dithionate, the resolution 0.3 mm is sufficient for mapping steep dose gradients if the dosemeters are covering only ±2 mm around the centre of the resonator. (authors)

  12. Real-time registration of 3D to 2D ultrasound images for image-guided prostate biopsy.

    Science.gov (United States)

    Gillies, Derek J; Gardi, Lori; De Silva, Tharindu; Zhao, Shuang-Ren; Fenster, Aaron

    2017-09-01

    During image-guided prostate biopsy, needles are targeted at tissues that are suspicious of cancer to obtain specimen for histological examination. Unfortunately, patient motion causes targeting errors when using an MR-transrectal ultrasound (TRUS) fusion approach to augment the conventional biopsy procedure. This study aims to develop an automatic motion correction algorithm approaching the frame rate of an ultrasound system to be used in fusion-based prostate biopsy systems. Two modes of operation have been investigated for the clinical implementation of the algorithm: motion compensation using a single user initiated correction performed prior to biopsy, and real-time continuous motion compensation performed automatically as a background process. Retrospective 2D and 3D TRUS patient images acquired prior to biopsy gun firing were registered using an intensity-based algorithm utilizing normalized cross-correlation and Powell's method for optimization. 2D and 3D images were downsampled and cropped to estimate the optimal amount of image information that would perform registrations quickly and accurately. The optimal search order during optimization was also analyzed to avoid local optima in the search space. Error in the algorithm was computed using target registration errors (TREs) from manually identified homologous fiducials in a clinical patient dataset. The algorithm was evaluated for real-time performance using the two different modes of clinical implementations by way of user initiated and continuous motion compensation methods on a tissue mimicking prostate phantom. After implementation in a TRUS-guided system with an image downsampling factor of 4, the proposed approach resulted in a mean ± std TRE and computation time of 1.6 ± 0.6 mm and 57 ± 20 ms respectively. The user initiated mode performed registrations with in-plane, out-of-plane, and roll motions computation times of 108 ± 38 ms, 60 ± 23 ms, and 89 ± 27 ms, respectively, and corresponding

  13. Topology-Preserving Rigid Transformation of 2D Digital Images.

    Science.gov (United States)

    Ngo, Phuc; Passat, Nicolas; Kenmochi, Yukiko; Talbot, Hugues

    2014-02-01

    We provide conditions under which 2D digital images preserve their topological properties under rigid transformations. We consider the two most common digital topology models, namely dual adjacency and well-composedness. This paper leads to the proposal of optimal preprocessing strategies that ensure the topological invariance of images under arbitrary rigid transformations. These results and methods are proved to be valid for various kinds of images (binary, gray-level, label), thus providing generic and efficient tools, which can be used in particular in the context of image registration and warping.

  14. Comparison of 3D cube FLAIR with 2D FLAIR for multiple sclerosis imaging at 3 tesla

    Energy Technology Data Exchange (ETDEWEB)

    Patzig, M.; Brueckmann, H.; Fesl, G. [Muenchen Univ. (Germany). Dept. of Neuroradiology; Burke, M. [GE Healthcare, Solingen (Germany)

    2014-05-15

    Purpose: Three-dimensional (3 D) MRI sequences allow improved spatial resolution with good signal and contrast properties as well as multiplanar reconstruction. We sought to compare Cube, a 3 D FLAIR sequence, to a standard 2 D FLAIR sequence in multiple sclerosis (MS) imaging. Materials and Methods: Examinations were performed in the clinical routine on a 3.0 Tesla scanner. 12 patients with definite MS were included. Lesions with MS-typical properties on the images of Cube FLAIR and 2 D FLAIR sequences were counted and allocated to different brain regions. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated. Results: With 384 the overall number of lesions found with Cube FLAIR was significantly higher than with 2 D FLAIR (N = 221). The difference was mostly accounted for by supratentorial lesions (N = 372 vs. N = 216) while the infratentorial lesion counts were low in both sequences. SNRs and CNRs were significantly higher in CUBE FLAIR with the exception of the CNR of lesion to gray matter, which was not significantly different. Conclusion: Cube FLAIR showed a higher sensitivity for MS lesions compared to a 2 D FLAIR sequence. 3 D FLAIR might replace 2 D FLAIR sequences in MS imaging in the future. (orig.)

  15. 3D composite image, 3D MRI, 3D SPECT, hydrocephalus

    International Nuclear Information System (INIS)

    Mito, T.; Shibata, I.; Sugo, N.; Takano, M.; Takahashi, H.

    2002-01-01

    2 by the use of a program prepared by combining the advantage of a surface rendering method with that of a volume rendering method by means of the general-purpose visualization software AVS-MV (Application Visualization System Medical Viewer). The AVS-MV permits production of semitransparent images as well, so that metabolic and physiological functions in internal tissues with the same threshold value can be seen through external tissues. The voxel and threshold distribution curve was plotted and analyzed by this software. The distribution of voxel in normal individuals shows such a bimodal curve that RI count presents a trough at a threshold value of 40% and a crest at 70%. In hydrocephalus, on the other hand, the 40% region showed an increase and 70% region showed a decrease . After shunt operation for hydrocephalus, with improvement in symptoms, the 40% region decreased and 70% region increased, so that a normal pattern was approached. This composite 3D MRI and SPECT imaging technique made it possible not only to establish an intracranial position in SPECT, but also to assess the profile of cerebral circulation around the cerebral venuicles. Analysis of these 3D composite images permits quantitative expression of brain volume in SPECT and extensive elucidation of the cerebral circulation profile in morphological detail. This analysis is, therefore, considered to contribute largely to the development of functional images

  16. Advanced 3-D Ultrasound Imaging

    DEFF Research Database (Denmark)

    Rasmussen, Morten Fischer

    The main purpose of the PhD project was to develop methods that increase the 3-D ultrasound imaging quality available for the medical personnel in the clinic. Acquiring a 3-D volume gives the medical doctor the freedom to investigate the measured anatomy in any slice desirable after the scan has...... been completed. This allows for precise measurements of organs dimensions and makes the scan more operator independent. Real-time 3-D ultrasound imaging is still not as widespread in use in the clinics as 2-D imaging. A limiting factor has traditionally been the low image quality achievable using...... a channel limited 2-D transducer array and the conventional 3-D beamforming technique, Parallel Beamforming. The first part of the scientific contributions demonstrate that 3-D synthetic aperture imaging achieves a better image quality than the Parallel Beamforming technique. Data were obtained using both...

  17. Challenges in the development of dopamine D2- and D3-selective radiotracers for PET imaging studies.

    Science.gov (United States)

    Mach, Robert H; Luedtke, Robert R

    2018-03-01

    The dopamine D2-like receptors (ie, D2/3 receptors) have been the most extensively studied CNS receptor with Positron Emission Tomography (PET). The 3 different radiotracers that have been used in these studies are [ 11 C]raclopride, [ 18 F]fallypride, and [ 11 C]PHNO. Because these radiotracers have a high affinity for both dopamine D2 and D3 receptors, the density of dopamine receptors in the CNS is reported as the D2/3 binding potential, which reflects a measure of the density of both receptor subtypes. Although the development of D2- and D3-selective PET radiotracers has been an active area of research for many years, this by and large presents an unmet need in the area of translational PET imaging studies. This article discusses some of the challenges that have inhibited progress in this area of research and the current status of the development of subtype selective radiotracers for imaging D3 and D2 dopamine receptors with PET. Copyright © 2017 John Wiley & Sons, Ltd.

  18. 2D and 3D imaging resolution trade-offs in quantifying pore throats for prediction of permeability

    Energy Technology Data Exchange (ETDEWEB)

    Beckingham, Lauren E.; Peters, Catherine A.; Um, Wooyong; Jones, Keith W.; Lindquist, W.Brent

    2013-09-03

    Although the impact of subsurface geochemical reactions on porosity is relatively well understood, changes in permeability remain difficult to estimate. In this work, pore-network modeling was used to predict permeability based on pore- and pore-throat size distributions determined from analysis of 2D scanning electron microscopy (SEM) images of thin sections and 3D X-ray computed microtomography (CMT) data. The analyzed specimens were a Viking sandstone sample from the Alberta sedimentary basin and an experimental column of reacted Hanford sediments. For the column, a decrease in permeability due to mineral precipitation was estimated, but the permeability estimates were dependent on imaging technique and resolution. X-ray CT imaging has the advantage of reconstructing a 3D pore network while 2D SEM imaging can easily analyze sub-grain and intragranular variations in mineralogy. Pore network models informed by analyses of 2D and 3D images at comparable resolutions produced permeability esti- mates with relatively good agreement. Large discrepancies in predicted permeabilities resulted from small variations in image resolution. Images with resolutions 0.4 to 4 lm predicted permeabilities differ- ing by orders of magnitude. While lower-resolution scans can analyze larger specimens, small pore throats may be missed due to resolution limitations, which in turn overestimates permeability in a pore-network model in which pore-to-pore conductances are statistically assigned. Conversely, high-res- olution scans are capable of capturing small pore throats, but if they are not actually flow-conducting predicted permeabilities will be below expected values. In addition, permeability is underestimated due to misinterpreting surface-roughness features as small pore throats. Comparison of permeability pre- dictions with expected and measured permeability values showed that the largest discrepancies resulted from the highest resolution images and the best predictions of

  19. Real-time 2-D Phased Array Vector Flow Imaging

    DEFF Research Database (Denmark)

    Holbek, Simon; Hansen, Kristoffer Lindskov; Fogh, Nikolaj

    2018-01-01

    Echocardiography examination of the blood flow is currently either restricted to 1-D techniques in real-time or experimental off-line 2-D methods. This paper presents an implementation of transverse oscillation for real-time 2-D vector flow imaging (VFI) on a commercial BK Ultrasound scanner....... A large field-of-view (FOV) sequence for studying flow dynamics at 11 frames per second (fps) and a sequence for studying peak systolic velocities (PSV) with a narrow FOV at 36 fps were validated. The VFI sequences were validated in a flow-rig with continuous laminar parabolic flow and in a pulsating flow...

  20. 3D Fast Spin Echo T2-weighted Contrast for Imaging the Female Cervix

    Science.gov (United States)

    Vargas Sanchez, Andrea Fernanda

    Magnetic Resonance Imaging (MRI) with T2-weighted contrast is the preferred modality for treatment planning and monitoring of cervical cancer. Current clinical protocols image the volume of interest multiple times with two dimensional (2D) T2-weighted MRI techniques. It is of interest to replace these multiple 2D acquisitions with a single three dimensional (3D) MRI acquisition to save time. However, at present the image contrast of standard 3D MRI does not distinguish cervical healthy tissue from cancerous tissue. The purpose of this thesis is to better understand the underlying factors that govern the contrast of 3D MRI and exploit this understanding via sequence modifications to improve the contrast. Numerical simulations are developed to predict observed contrast alterations and to propose an improvement. Improvements of image contrast are shown in simulation and with healthy volunteers. Reported results are only preliminary but a promising start to establish definitively 3D MRI for cervical cancer applications.

  1. GPU accelerated generation of digitally reconstructed radiographs for 2-D/3-D image registration.

    Science.gov (United States)

    Dorgham, Osama M; Laycock, Stephen D; Fisher, Mark H

    2012-09-01

    Recent advances in programming languages for graphics processing units (GPUs) provide developers with a convenient way of implementing applications which can be executed on the CPU and GPU interchangeably. GPUs are becoming relatively cheap, powerful, and widely available hardware components, which can be used to perform intensive calculations. The last decade of hardware performance developments shows that GPU-based computation is progressing significantly faster than CPU-based computation, particularly if one considers the execution of highly parallelisable algorithms. Future predictions illustrate that this trend is likely to continue. In this paper, we introduce a way of accelerating 2-D/3-D image registration by developing a hybrid system which executes on the CPU and utilizes the GPU for parallelizing the generation of digitally reconstructed radiographs (DRRs). Based on the advancements of the GPU over the CPU, it is timely to exploit the benefits of many-core GPU technology by developing algorithms for DRR generation. Although some previous work has investigated the rendering of DRRs using the GPU, this paper investigates approximations which reduce the computational overhead while still maintaining a quality consistent with that needed for 2-D/3-D registration with sufficient accuracy to be clinically acceptable in certain applications of radiation oncology. Furthermore, by comparing implementations of 2-D/3-D registration on the CPU and GPU, we investigate current performance and propose an optimal framework for PC implementations addressing the rigid registration problem. Using this framework, we are able to render DRR images from a 256×256×133 CT volume in ~24 ms using an NVidia GeForce 8800 GTX and in ~2 ms using NVidia GeForce GTX 580. In addition to applications requiring fast automatic patient setup, these levels of performance suggest image-guided radiation therapy at video frame rates is technically feasible using relatively low cost PC

  2. 2D array design based on Fermat spiral for ultrasound imaging.

    Science.gov (United States)

    Martínez-Graullera, Oscar; Martín, Carlos J; Godoy, Gregorio; Ullate, Luis G

    2010-02-01

    The main challenge faced by 3D ultrasonic imaging with 2D array transducers is the large number of elements required to achieve an acceptable level of quality in the images. Therefore, the optimisation of the array layout, in order to reduce the number of active elements in the aperture, has been a research topic in the last years. Nowadays, array technology has made viable the production of 2D arrays with larger flexibility on elements size, shape and position, allowing to study other configurations different to the classical matrix organisation, such as circular, archimedes spiral or polygonal layout between others. In this work, the problem of designing an imaging system array with large apertures and a very limited number of active elements (N(e)=128 and N(e)=256) using the Fermat spiral layout has been studied. As summary, a general discussion about the most interesting cases is presented.

  3. Automatic Depth Extraction from 2D Images Using a Cluster-Based Learning Framework.

    Science.gov (United States)

    Herrera, Jose L; Del-Blanco, Carlos R; Garcia, Narciso

    2018-07-01

    There has been a significant increase in the availability of 3D players and displays in the last years. Nonetheless, the amount of 3D content has not experimented an increment of such magnitude. To alleviate this problem, many algorithms for converting images and videos from 2D to 3D have been proposed. Here, we present an automatic learning-based 2D-3D image conversion approach, based on the key hypothesis that color images with similar structure likely present a similar depth structure. The presented algorithm estimates the depth of a color query image using the prior knowledge provided by a repository of color + depth images. The algorithm clusters this database attending to their structural similarity, and then creates a representative of each color-depth image cluster that will be used as prior depth map. The selection of the appropriate prior depth map corresponding to one given color query image is accomplished by comparing the structural similarity in the color domain between the query image and the database. The comparison is based on a K-Nearest Neighbor framework that uses a learning procedure to build an adaptive combination of image feature descriptors. The best correspondences determine the cluster, and in turn the associated prior depth map. Finally, this prior estimation is enhanced through a segmentation-guided filtering that obtains the final depth map estimation. This approach has been tested using two publicly available databases, and compared with several state-of-the-art algorithms in order to prove its efficiency.

  4. 2D-3D radiograph to cone-beam computed tomography (CBCT) registration for C-arm image-guided robotic surgery.

    Science.gov (United States)

    Liu, Wen Pei; Otake, Yoshito; Azizian, Mahdi; Wagner, Oliver J; Sorger, Jonathan M; Armand, Mehran; Taylor, Russell H

    2015-08-01

    C-arm radiographs are commonly used for intraoperative image guidance in surgical interventions. Fluoroscopy is a cost-effective real-time modality, although image quality can vary greatly depending on the target anatomy. Cone-beam computed tomography (CBCT) scans are sometimes available, so 2D-3D registration is needed for intra-procedural guidance. C-arm radiographs were registered to CBCT scans and used for 3D localization of peritumor fiducials during a minimally invasive thoracic intervention with a da Vinci Si robot. Intensity-based 2D-3D registration of intraoperative radiographs to CBCT was performed. The feasible range of X-ray projections achievable by a C-arm positioned around a da Vinci Si surgical robot, configured for robotic wedge resection, was determined using phantom models. Experiments were conducted on synthetic phantoms and animals imaged with an OEC 9600 and a Siemens Artis zeego, representing the spectrum of different C-arm systems currently available for clinical use. The image guidance workflow was feasible using either an optically tracked OEC 9600 or a Siemens Artis zeego C-arm, resulting in an angular difference of Δθ:∼ 30°. The two C-arm systems provided TRE mean ≤ 2.5 mm and TRE mean ≤ 2.0 mm, respectively (i.e., comparable to standard clinical intraoperative navigation systems). C-arm 3D localization from dual 2D-3D registered radiographs was feasible and applicable for intraoperative image guidance during da Vinci robotic thoracic interventions using the proposed workflow. Tissue deformation and in vivo experiments are required before clinical evaluation of this system.

  5. A software tool for automatic classification and segmentation of 2D/3D medical images

    International Nuclear Information System (INIS)

    Strzelecki, Michal; Szczypinski, Piotr; Materka, Andrzej; Klepaczko, Artur

    2013-01-01

    Modern medical diagnosis utilizes techniques of visualization of human internal organs (CT, MRI) or of its metabolism (PET). However, evaluation of acquired images made by human experts is usually subjective and qualitative only. Quantitative analysis of MR data, including tissue classification and segmentation, is necessary to perform e.g. attenuation compensation, motion detection, and correction of partial volume effect in PET images, acquired with PET/MR scanners. This article presents briefly a MaZda software package, which supports 2D and 3D medical image analysis aiming at quantification of image texture. MaZda implements procedures for evaluation, selection and extraction of highly discriminative texture attributes combined with various classification, visualization and segmentation tools. Examples of MaZda application in medical studies are also provided

  6. A software tool for automatic classification and segmentation of 2D/3D medical images

    Energy Technology Data Exchange (ETDEWEB)

    Strzelecki, Michal, E-mail: michal.strzelecki@p.lodz.pl [Institute of Electronics, Technical University of Lodz, Wolczanska 211/215, 90-924 Lodz (Poland); Szczypinski, Piotr; Materka, Andrzej; Klepaczko, Artur [Institute of Electronics, Technical University of Lodz, Wolczanska 211/215, 90-924 Lodz (Poland)

    2013-02-21

    Modern medical diagnosis utilizes techniques of visualization of human internal organs (CT, MRI) or of its metabolism (PET). However, evaluation of acquired images made by human experts is usually subjective and qualitative only. Quantitative analysis of MR data, including tissue classification and segmentation, is necessary to perform e.g. attenuation compensation, motion detection, and correction of partial volume effect in PET images, acquired with PET/MR scanners. This article presents briefly a MaZda software package, which supports 2D and 3D medical image analysis aiming at quantification of image texture. MaZda implements procedures for evaluation, selection and extraction of highly discriminative texture attributes combined with various classification, visualization and segmentation tools. Examples of MaZda application in medical studies are also provided.

  7. Symmetries of the 2D magnetic particle imaging system matrix

    International Nuclear Information System (INIS)

    Weber, A; Knopp, T

    2015-01-01

    In magnetic particle imaging (MPI), the relation between the particle distribution and the measurement signal can be described by a linear system of equations. For 1D imaging, it can be shown that the system matrix can be expressed as a product of a convolution matrix and a Chebyshev transformation matrix. For multidimensional imaging, the structure of the MPI system matrix is not yet fully explored as the sampling trajectory complicates the physical model. It has been experimentally found that the MPI system matrix rows have symmetries and look similar to the tensor products of Chebyshev polynomials. In this work we will mathematically prove that the 2D MPI system matrix has symmetries that can be used for matrix compression. (paper)

  8. Feasibility study on 3D image reconstruction from 2D orthogonal cine-MRI for MRI-guided radiotherapy.

    Science.gov (United States)

    Paganelli, Chiara; Lee, Danny; Kipritidis, John; Whelan, Brendan; Greer, Peter B; Baroni, Guido; Riboldi, Marco; Keall, Paul

    2018-02-11

    In-room MRI is a promising image guidance strategy in external beam radiotherapy to acquire volumetric information for moving targets. However, limitations in spatio-temporal resolution led several authors to use 2D orthogonal images for guidance. The aim of this work is to present a method to concurrently compensate for non-rigid tumour motion and provide an approach for 3D reconstruction from 2D orthogonal cine-MRI slices for MRI-guided treatments. Free-breathing sagittal/coronal interleaved 2D cine-MRI were acquired in addition to a pre-treatment 3D volume in two patients. We performed deformable image registration (DIR) between cine-MRI slices and corresponding slices in the pre-treatment 3D volume. Based on an extrapolation of the interleaved 2D motion fields, the 3D motion field was estimated and used to warp the pre-treatment volume. Due to the lack of a ground truth for patients, the method was validated on a digital 4D lung phantom. On the phantom, the 3D reconstruction method was able to compensate for tumour motion and compared favourably to the results of previously adopted strategies. The difference in the 3D motion fields between the phantom and the extrapolated motion was 0.4 ± 0.3 mm for tumour and 0.8 ± 1.5 mm for whole anatomy, demonstrating feasibility of performing a 3D volumetric reconstruction directly from 2D orthogonal cine-MRI slices. Application of the method to patient data confirmed the feasibility of utilizing this method in real world scenarios. Preliminary results on phantom and patient cases confirm the feasibility of the proposed approach in an MRI-guided scenario, especially for non-rigid tumour motion compensation. © 2018 The Royal Australian and New Zealand College of Radiologists.

  9. From 2D PET to 3D PET. Issues of data representation and image reconstruction

    International Nuclear Information System (INIS)

    Gundlich, B.; Musmann, P.; Weber, S.; Nix, O.; Semmler, W.

    2006-01-01

    Positron emission tomography (PET), intrinsically a 3D imaging technique, was for a long time exclusively operated in 2D mode, using septa to shield the detectors from photons emitted obliquely to the detector planes. However, the use of septa results in a considerable loss of sensitivity. From the late 1980s, significant efforts have been made to develop a methodology for the acquisition and reconstruction of 3D PET data. This paper focuses on the differences between data acquisition in 2D and 3D mode, especially in terms of data set sizes and representation. Although the real time data acquisition aspect in 3D has been mostly solved in modern PET scanner systems, there still remain questions on how to represent and how to make best use of the information contained in the acquired data sets. Data representation methods, such as list-mode and matrix-based methods, possibly with additional compression, will be discussed. Moving from 2D to 3D PET has major implications on the way these data are reconstructed to images. Two fundamentally different approaches exist, the analytical one and the iterative one. Both, at different expenses, can be extended to directly handle 3D data sets. Either way the computational burden increases heavily compared to 2D reconstruction. One possibility to benefit from the increased sensitivity in 3D PET while sticking to high-performance 2D reconstruction algorithms is to rebin 3D into 2D data sets. The value of data rebinning will be explored. An ever increasing computing power and the concept of distributed or parallel computing have made direct 3D reconstruction feasible. Following a short review of reconstruction methods and their extensions to 3D, we focus on numerical aspects that improve reconstruction performance, which is especially important in solving large equation systems in 3D iterative reconstruction. Finally exemplary results are shown to review the properties of the discussed algorithms. (orig.)

  10. Quantitative comparison of 2D and 3D late gadolinium enhancement MR imaging in patients with Fabry disease and hypertrophic cardiomyopathy.

    Science.gov (United States)

    Morsbach, F; Gordic, S; Gruner, C; Niemann, M; Goetti, R; Gotschy, A; Kozerke, S; Alkadhi, H; Manka, R

    2016-08-15

    This study aims to determine whether the quantification of myocardial fibrosis in patients with Fabry disease (FD) and hypertrophic cardiomyopathy (HCM) using a late gadolinium enhancement (LGE) singlebreath-hold three-dimensional (3D) inversion recovery magnetic resonance (MR) imaging sequence is comparable with a clinically established two-dimensional (2D) multi-breath-hold sequence. In this retrospective, IRB-approved study, 40 consecutive patients (18 male; mean age 50±17years) with Fabry disease (n=18) and HCM (n=22) underwent MR imaging at 1.5T. Spatial resolution was the same for 3D and 2D images (field-of-view, 350×350mm(2); in-plane-resolution, 1.2×1.2mm(2); section-thickness, 8mm). Datasets were analyzed for subjective image quality; myocardial and fibrotic mass, and total fibrotic tissue percentage were quantified. There was no significant difference in subjective image quality between 3D and 2D acquisitions (P=0.1 and P=0.3) for either disease. In patients with Fabry disease there were no significant differences between 3D and 2D acquisitions for myocardial mass (P=0.55), fibrous tissue mass (P=0.89), and total fibrous percentage (P=0.67), with good agreement between acquisitions according to Bland-Altman analyses. In patients with HCM there were also no significant differences between acquisitions for myocardial mass (P=0.48), fibrous tissue mass (P=0.56), and total fibrous percentage (P=0.67), with good agreement according to Bland-Altman analyses. Acquisition time was significantly shorter for 3D (25±5s) as compared to the 2D sequence (349±62s, P<0.001). In patients with Fabry disease and HCM, 3D LGE imaging provides equivalent diagnostic information in regard to quantification of myocardial fibrosis as compared with a standard 2D sequence, but at superior acquisition speed. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Multifractal analysis of 2D gray soil images

    Science.gov (United States)

    González-Torres, Ivan; Losada, Juan Carlos; Heck, Richard; Tarquis, Ana M.

    2015-04-01

    Soil structure, understood as the spatial arrangement of soil pores, is one of the key factors in soil modelling processes. Geometric properties of individual and interpretation of the morphological parameters of pores can be estimated from thin sections or 3D Computed Tomography images (Tarquis et al., 2003), but there is no satisfactory method to binarized these images and quantify the complexity of their spatial arrangement (Tarquis et al., 2008, Tarquis et al., 2009; Baveye et al., 2010). The objective of this work was to apply a multifractal technique, their singularities (α) and f(α) spectra, to quantify it without applying any threshold (Gónzalez-Torres, 2014). Intact soil samples were collected from four horizons of an Argisol, formed on the Tertiary Barreiras group of formations in Pernambuco state, Brazil (Itapirema Experimental Station). The natural vegetation of the region is tropical, coastal rainforest. From each horizon, showing different porosities and spatial arrangements, three adjacent samples were taken having a set of twelve samples. The intact soil samples were imaged using an EVS (now GE Medical. London, Canada) MS-8 MicroCT scanner with 45 μm pixel-1 resolution (256x256 pixels). Though some samples required paring to fit the 64 mm diameter imaging tubes, field orientation was maintained. References Baveye, P.C., M. Laba, W. Otten, L. Bouckaert, P. Dello, R.R. Goswami, D. Grinev, A. Houston, Yaoping Hu, Jianli Liu, S. Mooney, R. Pajor, S. Sleutel, A. Tarquis, Wei Wang, Qiao Wei, Mehmet Sezgin. Observer-dependent variability of the thresholding step in the quantitative analysis of soil images and X-ray microtomography data. Geoderma, 157, 51-63, 2010. González-Torres, Iván. Theory and application of multifractal analysis methods in images for the study of soil structure. Master thesis, UPM, 2014. Tarquis, A.M., R.J. Heck, J.B. Grau; J. Fabregat, M.E. Sanchez and J.M. Antón. Influence of Thresholding in Mass and Entropy Dimension of 3-D

  12. Image Quality Assessment of 2D versus 3D T2WI and Evaluation of Ultra-high b-Value (b=2,000 mm/s2) DWI for Response Assessment in Rectal Cancer.

    Science.gov (United States)

    Hausmann, Daniel; Liu, Jing; Budjan, Johannes; Reichert, Miriam; Ong, Melissa; Meyer, Mathias; Smakic, Arman; Grimm, Robert; Strecker, Ralph; Schoenberg, Stefan O; Wang, Xiaoying; Attenberger, Ulrike I

    2018-02-01

    The purpose of this IRB-approved, retrospective study was to compare image quality between 2D and high-resolution 3D, T2-weighted (T2WI) magnetic resonance imaging (MRI) sequences and to investigate the additional value of ultra-high b-value diffusion-weighted imaging (DWI; b=2,000 mm/s 2 ) for both rectal cancer staging and evaluating treatment response. From 12 February to 24 August 2016, 26 consecutive patients (22 males, four females; mean age: 61.9±14.0 years) with histologically-proven rectal cancer. In total 31 examinations [12 prior to and 19 after chemoradiation (CRT)] were included. The patients underwent pelvic MRI on a 3.0-T scanner (Magnetom Skyra, Erlangen, Germany). Three radiologists (3, 4, and 5 years of experience in MRI, respectively) independently assessed all images and rated the image quality of DWI (b=800 mm/s 2 ), apparent diffusion coefficient map, DWI (b=2,000 mm/s 2 ), 3D sagittal T2WI, 3D axial T2WI, 2D sagittal T2WI, and 2D axial T2WI of each patient, respectively. In addition, signal intensity ratios (SIR) were calculated between rectal cancer and obturator internus muscle (background) in all patients after CRT on DWI (b=2,000 mm/s 2 ) and correlated with histopathological regression grade (RG). Tumor delineation was significantly better by 2D T2WI than 3D T2WI both before and after CRT (before CRT: Z=-3.2, p=0.02; after CRT: Z=-4.408, p3D sagittal: 4.00±0.48; 2D sagittal: 4.03±0.34, p=0.713; 3D axial: 3.85±0.61, 2D axial: 3.78±0.64, p=0.537). Independent t-test showed significantly higher SIR between those with RG 1 or 2 (moderate response: mean score=2.02) and those with RG 3+4 (good response: mean score=0.8) (t=3.044, p=0.011). In those with RG 4 (complete response), SIR of b2000 was 0.946 compared to a 1.41 average of the whole cohort. In two patients, tumor was invisible on b2000 following CRT (RG 3 and 4, respectively). Interobserver agreement was mostly good (κ≥0.6) regarding image quality assessment, except for poor

  13. Calibration model of a dual gain flat panel detector for 2D and 3D x-ray imaging

    International Nuclear Information System (INIS)

    Schmidgunst, C.; Ritter, D.; Lang, E.

    2007-01-01

    The continuing research and further development in flat panel detector technology have led to its integration into more and more medical x-ray systems for two-dimensional (2D) and three-dimensional (3D) imaging, such as fixed or mobile C arms. Besides the obvious advantages of flat panel detectors, like the slim design and the resulting optimum accessibility to the patient, their success is primarily a product of the image quality that can be achieved. The benefits in the physical and performance-related features as opposed to conventional image intensifier systems (e.g., distortion-free reproduction of imaging information or almost linear signal response over a large dynamic range) can be fully exploited, however, only if the raw detector images are correctly calibrated and postprocessed. Previous procedures for processing raw data contain idealizations that, in the real world, lead to artifacts or losses in image quality. Thus, for example, temperature dependencies or changes in beam geometry, as can occur with mobile C arm systems, have not been taken into account up to this time. Additionally, adverse characteristics such as image lag or aging effects have to be compensated to attain the best possible image quality. In this article a procedure is presented that takes into account the important dependencies of the individual pixel sensitivity of flat panel detectors used in 2D or 3D imaging and simultaneously minimizes the work required for an extensive recalibration. It is suitable for conventional detectors with only one gain mode as well as for the detectors specially developed for 3D imaging with dual gain read-out technology

  14. Visual grading of 2D and 3D functional MRI compared with image-based descriptive measures

    Energy Technology Data Exchange (ETDEWEB)

    Ragnehed, Mattias [Linkoeping University, Division of Radiological Sciences, Radiology, IMH, Linkoeping (Sweden); Linkoeping University, Center for Medical Image Science and Visualization, CMIV, Linkoeping (Sweden); Linkoeping University, Department of Medical and Health Sciences, Division of Radiological Sciences/Radiology, Faculty of Health Sciences, Linkoeping (Sweden); Leinhard, Olof Dahlqvist; Pihlsgaard, Johan; Lundberg, Peter [Linkoeping University, Center for Medical Image Science and Visualization, CMIV, Linkoeping (Sweden); Linkoeping University, Division of Radiological Sciences, Radiation Physics, IMH, Linkoeping (Sweden); Wirell, Staffan [Linkoeping University, Division of Radiological Sciences, Radiology, IMH, Linkoeping (Sweden); Linkoeping University Hospital, Department of Radiology, Linkoeping (Sweden); Soekjer, Hannibal; Faegerstam, Patrik [Linkoeping University Hospital, Department of Radiology, Linkoeping (Sweden); Jiang, Bo [Linkoeping University, Center for Medical Image Science and Visualization, CMIV, Linkoeping (Sweden); Smedby, Oerjan; Engstroem, Maria [Linkoeping University, Division of Radiological Sciences, Radiology, IMH, Linkoeping (Sweden); Linkoeping University, Center for Medical Image Science and Visualization, CMIV, Linkoeping (Sweden)

    2010-03-15

    A prerequisite for successful clinical use of functional magnetic resonance imaging (fMRI) is the selection of an appropriate imaging sequence. The aim of this study was to compare 2D and 3D fMRI sequences using different image quality assessment methods. Descriptive image measures, such as activation volume and temporal signal-to-noise ratio (TSNR), were compared with results from visual grading characteristics (VGC) analysis of the fMRI results. Significant differences in activation volume and TSNR were not directly reflected by differences in VGC scores. The results suggest that better performance on descriptive image measures is not always an indicator of improved diagnostic quality of the fMRI results. In addition to descriptive image measures, it is important to include measures of diagnostic quality when comparing different fMRI data acquisition methods. (orig.)

  15. Injectable Colloidal Gold for Use in Intrafractional 2D Image-Guided Radiation Therapy

    DEFF Research Database (Denmark)

    Jølck, Rasmus Irming; Rydhog, Jonas S.; Christensen, Anders Nymark

    2015-01-01

    radio-opacity, which allows for marker-based image guidance in 2D and 3D X-ray imaging during radiation therapy. This is achieved by surface-engineering gold nanoparticles to be highly compatible with a carbohydrate-based gelation matrix. The new fiducial marker is investigated in mice where...

  16. High-resolution T2-weighted MR imaging of the inner ear using a long echo-train-length 3D fast spin-echo sequence

    International Nuclear Information System (INIS)

    Naganawa, S.; Yamakawa, K.; Fukatsu, H.; Ishigaki, T.; Nakashima, T.; Sugimoto, H.; Aoki, I.; Miyazaki, M.; Takai, H.

    1996-01-01

    The purpose of this study was to assess the value of a long echo-train-length 3D fast spin-echo (3D-FSE) sequence in visualizing the inner ear structures. Ten normal ears and 50 patient ears were imaged on a 1.5T MR unit using a head coil. Axial high-resolution T2-weighted images of the inner ear and the internal auditory canal (IAC) were obtained in 15 min. In normal ears the reliability of the visualization for the inner ear structures was evaluated on original images and the targeted maximum intensity projection (MIP) images of the labyrinth. In ten normal ears, 3D surface display (3D) images were also created and compared with MIP images. On the original images the cochlear aqueduct, the vessels in the vicinity of the IAC, and more than three branches of the cranial nerves were visualized in the IAC in all the ears. The visibility of the endolympathic duct was 80%. On the MIP images the visibility of the three semicircular canals, anterior and posterior ampulla, and of more than two turns of the cochlea was 100%. The MIP images and 3D images were almost comparable. The visibility of the endolymphatic duct was 80% in normal ears and 0% in the affected ears of the patients with Meniere's disease (p<0.001). In one patient ear a small intracanalicular tumor was depicted clearly. In conclusion, the long echo train length T2-weighted 3D-FSE sequence enables the detailed visualization of the tiny structures of the inner ear and the IAC within a clinically acceptable scan time. Furthermore, obtaining a high contrast between the soft/bony tissue and the cerebrospinal/endolymph/perilymph fluid would be of significant value in the diagnosis of the pathologic conditions around the labyrinth and the IAC. (orig.)

  17. Assessment of array scintillation detector for follicle thyroid 2-d image acquisition using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Silva, Carlos Borges da; Braz, Delson

    2008-01-01

    Full text: This work presents an innovative study to find out the adequate scintillation inorganic detector array to be used coupled to a specific light photo sensor, a charge coupled device (CCD), through a fiber optic plate. The goal is to choose the type of detector that fits a 2-dimensional imaging acquisition of a cell thyroid tissue application with high resolution and detection efficiency in order to map a follicle image using gamma radiation emission. A point or volumetric source-detector simulation by using a MCNP4B general code, considering different source energies, detector materials and geometry including pixel sizes and reflector types was performed. In this study, simulations were performed for 7 x 7, 31 x 31 and 127 x 127 arrays using CsI(Tl), BGO, CdWO 4 , LSO, GOS and GSO scintillation detectors with pixel dimensions ranging from 1 x 1 cm 2 to 10 x 10 μm 2 and radiation thickness ranging from 1 mm to 10 mm. The effect of all these parameters was investigated to find the best source-detector system that results in an image with the best contrast details. The results showed that it is possible to design a specific imaging system that allows searching for in-vitro studies, specifically in radiobiology applied to endocrine physiology. A 2D image of two thyroid follicles simulated by using MCNP4B code is shown

  18. 2-D response mapping of multi-linear silicon drift detectors

    International Nuclear Information System (INIS)

    Castoldi, A.; Guazzoni, C.; Hartmann, R.; Mezza, D.; Strueder, L.; Tassan Garofolo, F.

    2010-01-01

    Multi-linear silicon drift detectors (MLSDDs) are good candidates to fulfill simultaneous requirements for 2-D position-sensing and spectroscopy applications. The optimization of their design and performance as 2-D imagers requires a detailed study of timing properties of the charge cloud in the MLSDD architecture. In particular it is important to experimentally determine the dependence of the measured amplitude and time-of-arrival on the photon position of interaction so as to derive the 2D detector response. In this paper we will present a detailed experimental characterization aimed at measuring the detector amplitude response and its timing response. The dependence of charge cloud drift time on precise position of interaction has been measured as a function of detector biasing conditions.

  19. 3-D Imaging using Row–Column-Addressed 2-D Arrays with a Diverging Lens: Phantom Study

    DEFF Research Database (Denmark)

    Bouzari, Hamed; Engholm, Mathias; Beers, Christopher

    2017-01-01

    A double-curved diverging lens over a flat row– column-addressed (RCA) 2-D array can extend its inherent rectilinear 3-D imaging field-of-view (FOV) to a curvilinear volume region, which is necessary for applications such as abdominal and cardiac imaging. A concave lens with radius of 12.7 mm...... was manufactured using RTV664 silicone. The diverging properties of the lens were evaluated based on measurements on several phantoms. The measured 6 dB FOV in contact with a material similar to human soft tissue was less than 15% different from the theoretical predictions, i.e., a curvilinear FOV of 32...

  20. Least Square NUFFT Methods Applied to 2D and 3D Radially Encoded MR Image Reconstruction

    Science.gov (United States)

    Song, Jiayu; Liu, Qing H.; Gewalt, Sally L.; Cofer, Gary; Johnson, G. Allan

    2009-01-01

    Radially encoded MR imaging (MRI) has gained increasing attention in applications such as hyperpolarized gas imaging, contrast-enhanced MR angiography, and dynamic imaging, due to its motion insensitivity and improved artifact properties. However, since the technique collects k-space samples nonuniformly, multidimensional (especially 3D) radially sampled MRI image reconstruction is challenging. The balance between reconstruction accuracy and speed becomes critical when a large data set is processed. Kaiser-Bessel gridding reconstruction has been widely used for non-Cartesian reconstruction. The objective of this work is to provide an alternative reconstruction option in high dimensions with on-the-fly kernels calculation. The work develops general multi-dimensional least square nonuniform fast Fourier transform (LS-NUFFT) algorithms and incorporates them into a k-space simulation and image reconstruction framework. The method is then applied to reconstruct the radially encoded k-space, although the method addresses general nonuniformity and is applicable to any non-Cartesian patterns. Performance assessments are made by comparing the LS-NUFFT based method with the conventional Kaiser-Bessel gridding method for 2D and 3D radially encoded computer simulated phantoms and physically scanned phantoms. The results show that the LS-NUFFT reconstruction method has better accuracy-speed efficiency than the Kaiser-Bessel gridding method when the kernel weights are calculated on the fly. The accuracy of the LS-NUFFT method depends on the choice of scaling factor, and it is found that for a particular conventional kernel function, using its corresponding deapodization function as scaling factor and utilizing it into the LS-NUFFT framework has the potential to improve accuracy. When a cosine scaling factor is used, in particular, the LS-NUFFT method is faster than Kaiser-Bessel gridding method because of a quasi closed-form solution. The method is successfully applied to 2D and

  1. 3-D portal image analysis in clinical practice: an evaluation of 2-D and 3-D analysis techniques as applied to 30 prostate cancer patients

    International Nuclear Information System (INIS)

    Remeijer, Peter; Geerlof, Erik; Ploeger, Lennert; Gilhuijs, Kenneth; Herk, Marcel van; Lebesque, Joos V.

    2000-01-01

    Purpose: To investigate the clinical importance and feasibility of a 3-D portal image analysis method in comparison with a standard 2-D portal image analysis method for pelvic irradiation techniques. Methods and Materials: In this study, images of 30 patients who were treated for prostate cancer were used. A total of 837 imaged fields were analyzed by a single technologist, using automatic 2-D and 3-D techniques independently. Standard deviations (SDs) of the random, systematic, and overall variations, and the overall mean were calculated for the resulting data sets (2-D and 3-D), in the three principal directions (left-right [L-R], cranial-caudal [C-C], anterior-posterior [A-P]). The 3-D analysis included rotations as well. For the translational differences between the three data sets, the overall SD and overall mean were computed. The influence of out-of-plane rotations on the 2-D registration accuracy was determined by analyzing the difference between the 2-D and 3-D translation data as function of rotations. To assess the reliability of the 2-D and 3-D methods, the number of times the automatic match was manually adjusted was counted. Finally, an estimate of the workload was made. Results: The SDs of the random and systematic components of the rotations around the three orthogonal axes were 1.1 (L-R), 0.6 (C-C), 0.5 (A-P) and 0.9 (L-R), 0.6 (C-C), 0.8 (A-P) degrees, respectively. The overall mean rotation around the L-R axis was 0.7 deg., which deviated significantly from zero. Translational setup errors were comparable for 2-D and 3-D analysis (ranging from 1.4 to 2.2 mm SD and from 1.5 to 2.5 mm SD, respectively). The variation of the difference between the 2-D and 3-D translation data increased from 1.1 mm (SD) for zero rotations to 2.7 mm (SD) for out-of-plane rotations of 3 deg., due to a reduced 2-D registration accuracy for large rotations. The number of times the analysis was not considered acceptable and was manually adjusted was 44% for the 2-D

  2. Derivation of Strike and Dip in Sedimentary Terrain Using 3D Image Interpretation Based on Airborne LiDAR Data

    Directory of Open Access Journals (Sweden)

    Chih-Hsiang Yeh

    2014-01-01

    Full Text Available Traditional geological mapping may be hindered by rough terrain and dense vegetation resulting in obscured geological details. The advent of airborne Light Detection and Ranging (LiDAR provides a very precise three-dimensional (3D digital terrain model (DTM. However, its full potential in complementing traditional geological mapping remains to be explored using 3D rendering techniques. This study uses two types of 3D images which differ in imaging principles to further explore the finer details of sedimentary terrain. Our purposes are to demonstrate detailed geological mapping with 3D rendering techniques, to generate LiDAR-derived 3D strata boundaries that are advantageous in generating 2D geological maps and cross sections, and to develop a new practice in deriving the strike and dip of bedding with LiDAR data using an example from the north bank of the Keelung River in northern Taiwan. We propose a geological mapping practice that improves efficiency and meets a high-precision mapping standard with up to 2 m resolution using airborne LiDAR data. Through field verification and assessment, LiDAR data manipulation with relevant 3D visualization is shown to be an effective approach in improving the details of existing geological maps, specifically in sedimentary terrain.

  3. High-resolution high-sensitivity elemental imaging by secondary ion mass spectrometry: from traditional 2D and 3D imaging to correlative microscopy

    International Nuclear Information System (INIS)

    Wirtz, T; Philipp, P; Audinot, J-N; Dowsett, D; Eswara, S

    2015-01-01

    Secondary ion mass spectrometry (SIMS) constitutes an extremely sensitive technique for imaging surfaces in 2D and 3D. Apart from its excellent sensitivity and high lateral resolution (50 nm on state-of-the-art SIMS instruments), advantages of SIMS include high dynamic range and the ability to differentiate between isotopes. This paper first reviews the underlying principles of SIMS as well as the performance and applications of 2D and 3D SIMS elemental imaging. The prospects for further improving the capabilities of SIMS imaging are discussed. The lateral resolution in SIMS imaging when using the microprobe mode is limited by (i) the ion probe size, which is dependent on the brightness of the primary ion source, the quality of the optics of the primary ion column and the electric fields in the near sample region used to extract secondary ions; (ii) the sensitivity of the analysis as a reasonable secondary ion signal, which must be detected from very tiny voxel sizes and thus from a very limited number of sputtered atoms; and (iii) the physical dimensions of the collision cascade determining the origin of the sputtered ions with respect to the impact site of the incident primary ion probe. One interesting prospect is the use of SIMS-based correlative microscopy. In this approach SIMS is combined with various high-resolution microscopy techniques, so that elemental/chemical information at the highest sensitivity can be obtained with SIMS, while excellent spatial resolution is provided by overlaying the SIMS images with high-resolution images obtained by these microscopy techniques. Examples of this approach are given by presenting in situ combinations of SIMS with transmission electron microscopy (TEM), helium ion microscopy (HIM) and scanning probe microscopy (SPM). (paper)

  4. Reconstructing 3D profiles of flux distribution in array of unshunted Josephson junctions from 2D scanning SQUID microscope images

    International Nuclear Information System (INIS)

    Nascimento, F.M.; Sergeenkov, S.; Araujo-Moreira, F.M.

    2012-01-01

    By using a specially designed algorithm (based on utilizing the so-called Hierarchical Data Format), we report on successful reconstruction of 3D profiles of local flux distribution within artificially prepared arrays of unshunted Nb-AlO x -Nb Josephson junctions from 2D surface images obtained via the scanning SQUID microscope. The analysis of the obtained results suggest that for large sweep areas, the local flux distribution significantly deviates from the conventional picture and exhibits a more complicated avalanche-type behavior with a prominent dendritic structure. -- Highlights: ► The penetration of external magnetic field into an array of Nb-AlO x -Nb Josephson junctions is studied. ► Using Scanning SQUID Microscope, 2D images of local flux distribution within array are obtained. ► Using specially designed pattern recognition algorithm, 3D flux profiles are reconstructed from 2D images.

  5. GREIT: a unified approach to 2D linear EIT reconstruction of lung images.

    Science.gov (United States)

    Adler, Andy; Arnold, John H; Bayford, Richard; Borsic, Andrea; Brown, Brian; Dixon, Paul; Faes, Theo J C; Frerichs, Inéz; Gagnon, Hervé; Gärber, Yvo; Grychtol, Bartłomiej; Hahn, Günter; Lionheart, William R B; Malik, Anjum; Patterson, Robert P; Stocks, Janet; Tizzard, Andrew; Weiler, Norbert; Wolf, Gerhard K

    2009-06-01

    Electrical impedance tomography (EIT) is an attractive method for clinically monitoring patients during mechanical ventilation, because it can provide a non-invasive continuous image of pulmonary impedance which indicates the distribution of ventilation. However, most clinical and physiological research in lung EIT is done using older and proprietary algorithms; this is an obstacle to interpretation of EIT images because the reconstructed images are not well characterized. To address this issue, we develop a consensus linear reconstruction algorithm for lung EIT, called GREIT (Graz consensus Reconstruction algorithm for EIT). This paper describes the unified approach to linear image reconstruction developed for GREIT. The framework for the linear reconstruction algorithm consists of (1) detailed finite element models of a representative adult and neonatal thorax, (2) consensus on the performance figures of merit for EIT image reconstruction and (3) a systematic approach to optimize a linear reconstruction matrix to desired performance measures. Consensus figures of merit, in order of importance, are (a) uniform amplitude response, (b) small and uniform position error, (c) small ringing artefacts, (d) uniform resolution, (e) limited shape deformation and (f) high resolution. Such figures of merit must be attained while maintaining small noise amplification and small sensitivity to electrode and boundary movement. This approach represents the consensus of a large and representative group of experts in EIT algorithm design and clinical applications for pulmonary monitoring. All software and data to implement and test the algorithm have been made available under an open source license which allows free research and commercial use.

  6. GREIT: a unified approach to 2D linear EIT reconstruction of lung images

    International Nuclear Information System (INIS)

    Adler, Andy; Arnold, John H; Bayford, Richard; Tizzard, Andrew; Borsic, Andrea; Brown, Brian; Dixon, Paul; Faes, Theo J C; Frerichs, Inéz; Weiler, Norbert; Gagnon, Hervé; Gärber, Yvo; Grychtol, Bartłomiej; Hahn, Günter; Lionheart, William R B; Malik, Anjum; Patterson, Robert P; Stocks, Janet; Wolf, Gerhard K

    2009-01-01

    Electrical impedance tomography (EIT) is an attractive method for clinically monitoring patients during mechanical ventilation, because it can provide a non-invasive continuous image of pulmonary impedance which indicates the distribution of ventilation. However, most clinical and physiological research in lung EIT is done using older and proprietary algorithms; this is an obstacle to interpretation of EIT images because the reconstructed images are not well characterized. To address this issue, we develop a consensus linear reconstruction algorithm for lung EIT, called GREIT (Graz consensus Reconstruction algorithm for EIT). This paper describes the unified approach to linear image reconstruction developed for GREIT. The framework for the linear reconstruction algorithm consists of (1) detailed finite element models of a representative adult and neonatal thorax, (2) consensus on the performance figures of merit for EIT image reconstruction and (3) a systematic approach to optimize a linear reconstruction matrix to desired performance measures. Consensus figures of merit, in order of importance, are (a) uniform amplitude response, (b) small and uniform position error, (c) small ringing artefacts, (d) uniform resolution, (e) limited shape deformation and (f) high resolution. Such figures of merit must be attained while maintaining small noise amplification and small sensitivity to electrode and boundary movement. This approach represents the consensus of a large and representative group of experts in EIT algorithm design and clinical applications for pulmonary monitoring. All software and data to implement and test the algorithm have been made available under an open source license which allows free research and commercial use

  7. Real-time 2D/3D registration using kV-MV image pairs for tumor motion tracking in image guided radiotherapy.

    Science.gov (United States)

    Furtado, Hugo; Steiner, Elisabeth; Stock, Markus; Georg, Dietmar; Birkfellner, Wolfgang

    2013-10-01

    Intra-fractional respiratory motion during radiotherapy leads to a larger planning target volume (PTV). Real-time tumor motion tracking by two-dimensional (2D)/3D registration using on-board kilo-voltage (kV) imaging can allow for a reduction of the PTV though motion along the imaging beam axis cannot be resolved using only one projection image. We present a retrospective patient study investigating the impact of paired portal mega-voltage (MV) and kV images on registration accuracy. Material and methods. We used data from 10 patients suffering from non-small cell lung cancer (NSCLC) undergoing stereotactic body radiation therapy (SBRT) lung treatment. For each patient we acquired a planning computed tomography (CT) and sequences of kV and MV images during treatment. We compared the accuracy of motion tracking in six degrees-of-freedom (DOF) using the anterior-posterior (AP) kV sequence or the sequence of kV-MV image pairs. Results. Motion along cranial-caudal direction could accurately be extracted when using only the kV sequence but in AP direction we obtained large errors. When using kV-MV pairs, the average error was reduced from 2.9 mm to 1.5 mm and the motion along AP was successfully extracted. Mean registration time was 188 ms. Conclusion. Our evaluation shows that using kV-MV image pairs leads to improved motion extraction in six DOF and is suitable for real-time tumor motion tracking with a conventional LINAC.

  8. 3D/2D model-to-image registration by imitation learning for cardiac procedures.

    Science.gov (United States)

    Toth, Daniel; Miao, Shun; Kurzendorfer, Tanja; Rinaldi, Christopher A; Liao, Rui; Mansi, Tommaso; Rhode, Kawal; Mountney, Peter

    2018-05-12

    In cardiac interventions, such as cardiac resynchronization therapy (CRT), image guidance can be enhanced by involving preoperative models. Multimodality 3D/2D registration for image guidance, however, remains a significant research challenge for fundamentally different image data, i.e., MR to X-ray. Registration methods must account for differences in intensity, contrast levels, resolution, dimensionality, field of view. Furthermore, same anatomical structures may not be visible in both modalities. Current approaches have focused on developing modality-specific solutions for individual clinical use cases, by introducing constraints, or identifying cross-modality information manually. Machine learning approaches have the potential to create more general registration platforms. However, training image to image methods would require large multimodal datasets and ground truth for each target application. This paper proposes a model-to-image registration approach instead, because it is common in image-guided interventions to create anatomical models for diagnosis, planning or guidance prior to procedures. An imitation learning-based method, trained on 702 datasets, is used to register preoperative models to intraoperative X-ray images. Accuracy is demonstrated on cardiac models and artificial X-rays generated from CTs. The registration error was [Formula: see text] on 1000 test cases, superior to that of manual ([Formula: see text]) and gradient-based ([Formula: see text]) registration. High robustness is shown in 19 clinical CRT cases. Besides the proposed methods feasibility in a clinical environment, evaluation has shown good accuracy and high robustness indicating that it could be applied in image-guided interventions.

  9. Registration of dynamic dopamine D2receptor images using principal component analysis

    International Nuclear Information System (INIS)

    Acton, P.D.; Ell, P.J.; Pilowsky, L.S.; Brammer, M.J.; Suckling, J.

    1997-01-01

    This paper describes a novel technique for registering a dynamic sequence of single-photon emission tomography (SPET) dopamine D 2 receptor images, using principal component analysis (PCA). Conventional methods for registering images, such as count difference and correlation coefficient algorithms, fail to take into account the dynamic nature of the data, resulting in large systematic errors when registering time-varying images. However, by using principal component analysis to extract the temporal structure of the image sequence, misregistration can be quantified by examining the distribution of eigenvalues. The registration procedures were tested using a computer-generated dynamic phantom derived from a high-resolution magnetic resonance image of a realistic brain phantom. Each method was also applied to clinical SPET images of dopamine D 2 receptors, using the ligands iodine-123 iodobenzamide and iodine-123 epidepride, to investigate the influence of misregistration on kinetic modelling parameters and the binding potential. The PCA technique gave highly significant (P 123 I-epidepride scans. The PCA method produced data of much greater quality for subsequent kinetic modelling, with an improvement of nearly 50% in the χ 2 of the fit to the compartmental model, and provided superior quality registration of particularly difficult dynamic sequences. (orig.)

  10. ON SOFT D2-ALGEBRA AND SOFT D2-IDEALS

    OpenAIRE

    S. Subramanian; S. Seethalaksmi

    2018-01-01

    In this paper, we have studied some characterization of soft D2-algebra, kernel, intersection, image, quotient D2-algebra’s and relations ship between D2-algebra and D2-ideals with suitable examples.

  11. Template Assembly for Detailed Urban Reconstruction

    KAUST Repository

    Nan, Liangliang

    2015-05-04

    We propose a new framework to reconstruct building details by automatically assembling 3D templates on coarse textured building models. In a preprocessing step, we generate an initial coarse model to approximate a point cloud computed using Structure from Motion and Multi View Stereo, and we model a set of 3D templates of facade details. Next, we optimize the initial coarse model to enforce consistency between geometry and appearance (texture images). Then, building details are reconstructed by assembling templates on the textured faces of the coarse model. The 3D templates are automatically chosen and located by our optimization-based template assembly algorithm that balances image matching and structural regularity. In the results, we demonstrate how our framework can enrich the details of coarse models using various data sets.

  12. 2-deoxy-2[F-18]fluoro-D-mannose positron emission tomography imaging in atherosclerosis

    NARCIS (Netherlands)

    Tahara, Nobuhiro; Mukherjee, Jogeshwar; de Haas, Hans J; Petrov, Artiom D; Tawakol, Ahmed; Haider, Nezam; Tahara, Atsuko; Constantinescu, Cristian C; Zhou, Jun; Boersma, Hendrikus H; Imaizumi, Tsutomu; Nakano, Masataka; Finn, Aloke; Fayad, Zahi; Virmani, Renu; Fuster, Valentin; Bosca, Lisardo; Narula, Jagat

    Progressive inflammation in atherosclerotic plaques is associated with increasing risk of plaque rupture. Molecular imaging of activated macrophages with 2-deoxy-2[F-18]fluoro-D-glucose ([F-18]FDG) has been proposed for identification of patients at higher risk for acute vascular events. Because

  13. SU-E-J-13: Six Degree of Freedom Image Fusion Accuracy for Cranial Target Localization On the Varian Edge Stereotactic Radiosurgery System: Comparison Between 2D/3D and KV CBCT Image Registration

    Energy Technology Data Exchange (ETDEWEB)

    Xu, H [Wayne State University, Detroit, MI (United States); Song, K; Chetty, I; Kim, J [Henry Ford Health System, Detroit, MI (United States); Wen, N [Henry Ford Health System, West Bloomfield, MI (United States)

    2015-06-15

    Purpose: To determine the 6 degree of freedom systematic deviations between 2D/3D and CBCT image registration with various imaging setups and fusion algorithms on the Varian Edge Linac. Methods: An anthropomorphic head phantom with radio opaque targets embedded was scanned with CT slice thicknesses of 0.8, 1, 2, and 3mm. The 6 DOF systematic errors were assessed by comparing 2D/3D (kV/MV with CT) with 3D/3D (CBCT with CT) image registrations with different offset positions, similarity measures, image filters, and CBCT slice thicknesses (1 and 2 mm). The 2D/3D registration accuracy of 51 fractions for 26 cranial SRS patients was also evaluated by analyzing 2D/3D pre-treatment verification taken after 3D/3D image registrations. Results: The systematic deviations of 2D/3D image registration using kV- kV, MV-kV and MV-MV image pairs were within ±0.3mm and ±0.3° for translations and rotations with 95% confidence interval (CI) for a reference CT with 0.8 mm slice thickness. No significant difference (P>0.05) on target localization was observed between 0.8mm, 1mm, and 2mm CT slice thicknesses with CBCT slice thicknesses of 1mm and 2mm. With 3mm CT slice thickness, both 2D/3D and 3D/3D registrations performed less accurately in longitudinal direction than thinner CT slice thickness (0.60±0.12mm and 0.63±0.07mm off, respectively). Using content filter and using similarity measure of pattern intensity instead of mutual information, improved the 2D/3D registration accuracy significantly (P=0.02 and P=0.01, respectively). For the patient study, means and standard deviations of residual errors were 0.09±0.32mm, −0.22±0.51mm and −0.07±0.32mm in VRT, LNG and LAT directions, respectively, and 0.12°±0.46°, −0.12°±0.39° and 0.06°±0.28° in RTN, PITCH, and ROLL directions, respectively. 95% CI of translational and rotational deviations were comparable to those in phantom study. Conclusion: 2D/3D image registration provided on the Varian Edge radiosurgery, 6 DOF

  14. SU-E-J-13: Six Degree of Freedom Image Fusion Accuracy for Cranial Target Localization On the Varian Edge Stereotactic Radiosurgery System: Comparison Between 2D/3D and KV CBCT Image Registration

    International Nuclear Information System (INIS)

    Xu, H; Song, K; Chetty, I; Kim, J; Wen, N

    2015-01-01

    Purpose: To determine the 6 degree of freedom systematic deviations between 2D/3D and CBCT image registration with various imaging setups and fusion algorithms on the Varian Edge Linac. Methods: An anthropomorphic head phantom with radio opaque targets embedded was scanned with CT slice thicknesses of 0.8, 1, 2, and 3mm. The 6 DOF systematic errors were assessed by comparing 2D/3D (kV/MV with CT) with 3D/3D (CBCT with CT) image registrations with different offset positions, similarity measures, image filters, and CBCT slice thicknesses (1 and 2 mm). The 2D/3D registration accuracy of 51 fractions for 26 cranial SRS patients was also evaluated by analyzing 2D/3D pre-treatment verification taken after 3D/3D image registrations. Results: The systematic deviations of 2D/3D image registration using kV- kV, MV-kV and MV-MV image pairs were within ±0.3mm and ±0.3° for translations and rotations with 95% confidence interval (CI) for a reference CT with 0.8 mm slice thickness. No significant difference (P>0.05) on target localization was observed between 0.8mm, 1mm, and 2mm CT slice thicknesses with CBCT slice thicknesses of 1mm and 2mm. With 3mm CT slice thickness, both 2D/3D and 3D/3D registrations performed less accurately in longitudinal direction than thinner CT slice thickness (0.60±0.12mm and 0.63±0.07mm off, respectively). Using content filter and using similarity measure of pattern intensity instead of mutual information, improved the 2D/3D registration accuracy significantly (P=0.02 and P=0.01, respectively). For the patient study, means and standard deviations of residual errors were 0.09±0.32mm, −0.22±0.51mm and −0.07±0.32mm in VRT, LNG and LAT directions, respectively, and 0.12°±0.46°, −0.12°±0.39° and 0.06°±0.28° in RTN, PITCH, and ROLL directions, respectively. 95% CI of translational and rotational deviations were comparable to those in phantom study. Conclusion: 2D/3D image registration provided on the Varian Edge radiosurgery, 6 DOF

  15. 3D ultrasound imaging for prosthesis fabrication and diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, A.K.; Bow, W.J.; Strong, D.S. [and others

    1995-06-01

    The fabrication of a prosthetic socket for a below-the-knee amputee requires knowledge of the underlying bone structure in order to provide pressure relief for sensitive areas and support for load bearing areas. The goal is to enable the residual limb to bear pressure with greater ease and utility. Conventional methods of prosthesis fabrication are based on limited knowledge about the patient`s underlying bone structure. A 3D ultrasound imaging system was developed at Sandia National Laboratories. The imaging system provides information about the location of the bones in the residual limb along with the shape of the skin surface. Computer assisted design (CAD) software can use this data to design prosthetic sockets for amputees. Ultrasound was selected as the imaging modality. A computer model was developed to analyze the effect of the various scanning parameters and to assist in the design of the overall system. The 3D ultrasound imaging system combines off-the-shelf technology for image capturing, custom hardware, and control and image processing software to generate two types of image data -- volumetric and planar. Both volumetric and planar images reveal definition of skin and bone geometry with planar images providing details on muscle fascial planes, muscle/fat interfaces, and blood vessel definition. The 3D ultrasound imaging system was tested on 9 unilateral below-the- knee amputees. Image data was acquired from both the sound limb and the residual limb. The imaging system was operated in both volumetric and planar formats. An x-ray CT (Computed Tomography) scan was performed on each amputee for comparison. Results of the test indicate beneficial use of ultrasound to generate databases for fabrication of prostheses at a lower cost and with better initial fit as compared to manually fabricated prostheses.

  16. 4D reconstruction of the past: the image retrieval and 3D model construction pipeline

    Science.gov (United States)

    Hadjiprocopis, Andreas; Ioannides, Marinos; Wenzel, Konrad; Rothermel, Mathias; Johnsons, Paul S.; Fritsch, Dieter; Doulamis, Anastasios; Protopapadakis, Eftychios; Kyriakaki, Georgia; Makantasis, Kostas; Weinlinger, Guenther; Klein, Michael; Fellner, Dieter; Stork, Andre; Santos, Pedro

    2014-08-01

    One of the main characteristics of the Internet era we are living in, is the free and online availability of a huge amount of data. This data is of varied reliability and accuracy and exists in various forms and formats. Often, it is cross-referenced and linked to other data, forming a nexus of text, images, animation and audio enabled by hypertext and, recently, by the Web3.0 standard. Our main goal is to enable historians, architects, archaeolo- gists, urban planners and affiliated professionals to reconstruct views of historical monuments from thousands of images floating around the web. This paper aims to provide an update of our progress in designing and imple- menting a pipeline for searching, filtering and retrieving photographs from Open Access Image Repositories and social media sites and using these images to build accurate 3D models of archaeological monuments as well as enriching multimedia of cultural / archaeological interest with metadata and harvesting the end products to EU- ROPEANA. We provide details of how our implemented software searches and retrieves images of archaeological sites from Flickr and Picasa repositories as well as strategies on how to filter the results, on two levels; a) based on their built-in metadata including geo-location information and b) based on image processing and clustering techniques. We also describe our implementation of a Structure from Motion pipeline designed for producing 3D models using the large collection of 2D input images (>1000) retrieved from Internet Repositories.

  17. 2D Geoelectric Imaging of the Uneme-Nekhua Fracture Zone

    Directory of Open Access Journals (Sweden)

    Muslim B. Aminu

    2014-01-01

    Full Text Available We have employed 2D geoelectric imaging to reveal the geometry and nature of a fracture zone in Uneme-Nekhua, southwestern Nigeria. The fracture zone is discernable from an outcropping rock scarp and appears to define the course of a seasonal stream. Data were acquired using the dipole-dipole survey array configuration with electrode separation of 6 m and a maximum dipole length of 60 m. Three traverses with lengths varying between 72 m and 120 m were laid orthogonal to the course of the seasonal stream. 2D geoelectric images of the subsurface along the profiles imaged a north-south trending fracture zone. This fracture zone appears to consist of two vertical fractures with more intense definition downstream. The eastern fracture is buried by recent sediment, while the western fracture appears to have experienced more recent tectonic activity as it appears to penetrate through the near surface. Perhaps at some point, deformation ceased on the eastern fracture and further strain was transferred to the western fracture. The fracture zone generally defines the course of the north-south seasonal stream with the exception of the downstream end where the fracture appears to have died out entirely. Two associated basement trenches lying parallel to and east of the fracture zone are also imaged.

  18. The Accuracy of 3D Optical Reconstruction and Additive Manufacturing Processes in Reproducing Detailed Subject-Specific Anatomy

    Directory of Open Access Journals (Sweden)

    Paolo Ferraiuoli

    2017-10-01

    Full Text Available 3D reconstruction and 3D printing of subject-specific anatomy is a promising technology for supporting clinicians in the visualisation of disease progression and planning for surgical intervention. In this context, the 3D model is typically obtained from segmentation of magnetic resonance imaging (MRI, computed tomography (CT or echocardiography images. Although these modalities allow imaging of the tissues in vivo, assessment of quality of the reconstruction is limited by the lack of a reference geometry as the subject-specific anatomy is unknown prior to image acquisition. In this work, an optical method based on 3D digital image correlation (3D-DIC techniques is used to reconstruct the shape of the surface of an ex vivo porcine heart. This technique requires two digital charge-coupled device (CCD cameras to provide full-field shape measurements and to generate a standard tessellation language (STL file of the sample surface. The aim of this work was to quantify the error of 3D-DIC shape measurements using the additive manufacturing process. The limitations of 3D printed object resolution, the discrepancy in reconstruction of the surface of cardiac soft tissue and a 3D printed model of the same surface were evaluated. The results obtained demonstrated the ability of the 3D-DIC technique to reconstruct localised and detailed features on the cardiac surface with sub-millimeter accuracy.

  19. An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imaging.

    Science.gov (United States)

    Wygant, Ira O; Jamal, Nafis S; Lee, Hyunjoo J; Nikoozadeh, Amin; Oralkan, Omer; Karaman, Mustafa; Khuri-Yakub, Butrus T

    2009-10-01

    State-of-the-art 3-D medical ultrasound imaging requires transmitting and receiving ultrasound using a 2-D array of ultrasound transducers with hundreds or thousands of elements. A tight combination of the transducer array with integrated circuitry eliminates bulky cables connecting the elements of the transducer array to a separate system of electronics. Furthermore, preamplifiers located close to the array can lead to improved receive sensitivity. A combined IC and transducer array can lead to a portable, high-performance, and inexpensive 3-D ultrasound imaging system. This paper presents an IC flip-chip bonded to a 16 x 16-element capacitive micromachined ultrasonic transducer (CMUT) array for 3-D ultrasound imaging. The IC includes a transmit beamformer that generates 25-V unipolar pulses with programmable focusing delays to 224 of the 256 transducer elements. One-shot circuits allow adjustment of the pulse widths for different ultrasound transducer center frequencies. For receiving reflected ultrasound signals, the IC uses the 32-elements along the array diagonals. The IC provides each receiving element with a low-noise 25-MHz-bandwidth transimpedance amplifier. Using a field-programmable gate array (FPGA) clocked at 100 MHz to operate the IC, the IC generated properly timed transmit pulses with 5-ns accuracy. With the IC flip-chip bonded to a CMUT array, we show that the IC can produce steered and focused ultrasound beams. We present 2-D and 3-D images of a wire phantom and 2-D orthogonal cross-sectional images (Bscans) of a latex heart phantom.

  20. 3D confocal imaging in CUBIC-cleared mouse heart

    Energy Technology Data Exchange (ETDEWEB)

    Nehrhoff, I.; Bocancea, D.; Vaquero, J.; Vaquero, J.J.; Lorrio, M.T.; Ripoll, J.; Desco, M.; Gomez-Gaviro, M.V.

    2016-07-01

    Acquiring high resolution 3D images of the heart enables the ability to study heart diseases more in detail. Here, the CUBIC (clear, unobstructed brain imaging cocktails and computational analysis) clearing protocol was adapted for thick mouse heart sections to increase the penetration depth of the confocal microscope lasers into the tissue. The adapted CUBIC clearing of the heart lets the antibody penetrate deeper into the tissue by a factor of five. The here shown protocol enables deep 3D highresolution image acquisition in the heart. This allows a much more accurate assessment of the cellular and structural changes that underlie heart diseases. (Author)

  1. 3D confocal imaging in CUBIC-cleared mouse heart

    International Nuclear Information System (INIS)

    Nehrhoff, I.; Bocancea, D.; Vaquero, J.; Vaquero, J.J.; Lorrio, M.T.; Ripoll, J.; Desco, M.; Gomez-Gaviro, M.V.

    2016-01-01

    Acquiring high resolution 3D images of the heart enables the ability to study heart diseases more in detail. Here, the CUBIC (clear, unobstructed brain imaging cocktails and computational analysis) clearing protocol was adapted for thick mouse heart sections to increase the penetration depth of the confocal microscope lasers into the tissue. The adapted CUBIC clearing of the heart lets the antibody penetrate deeper into the tissue by a factor of five. The here shown protocol enables deep 3D highresolution image acquisition in the heart. This allows a much more accurate assessment of the cellular and structural changes that underlie heart diseases. (Author)

  2. Synchronized 2D/3D optical mapping for interactive exploration and real-time visualization of multi-function neurological images.

    Science.gov (United States)

    Zhang, Qi; Alexander, Murray; Ryner, Lawrence

    2013-01-01

    Efficient software with the ability to display multiple neurological image datasets simultaneously with full real-time interactivity is critical for brain disease diagnosis and image-guided planning. In this paper, we describe the creation and function of a new comprehensive software platform that integrates novel algorithms and functions for multiple medical image visualization, processing, and manipulation. We implement an opacity-adjustment algorithm to build 2D lookup tables for multiple slice image display and fusion, which achieves a better visual result than those of using VTK-based methods. We also develop a new real-time 2D and 3D data synchronization scheme for multi-function MR volume and slice image optical mapping and rendering simultaneously through using the same adjustment operation. All these methodologies are integrated into our software framework to provide users with an efficient tool for flexibly, intuitively, and rapidly exploring and analyzing the functional and anatomical MR neurological data. Finally, we validate our new techniques and software platform with visual analysis and task-specific user studies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Performance evaluation of 2D and 3D deep learning approaches for automatic segmentation of multiple organs on CT images

    Science.gov (United States)

    Zhou, Xiangrong; Yamada, Kazuma; Kojima, Takuya; Takayama, Ryosuke; Wang, Song; Zhou, Xinxin; Hara, Takeshi; Fujita, Hiroshi

    2018-02-01

    The purpose of this study is to evaluate and compare the performance of modern deep learning techniques for automatically recognizing and segmenting multiple organ regions on 3D CT images. CT image segmentation is one of the important task in medical image analysis and is still very challenging. Deep learning approaches have demonstrated the capability of scene recognition and semantic segmentation on nature images and have been used to address segmentation problems of medical images. Although several works showed promising results of CT image segmentation by using deep learning approaches, there is no comprehensive evaluation of segmentation performance of the deep learning on segmenting multiple organs on different portions of CT scans. In this paper, we evaluated and compared the segmentation performance of two different deep learning approaches that used 2D- and 3D deep convolutional neural networks (CNN) without- and with a pre-processing step. A conventional approach that presents the state-of-the-art performance of CT image segmentation without deep learning was also used for comparison. A dataset that includes 240 CT images scanned on different portions of human bodies was used for performance evaluation. The maximum number of 17 types of organ regions in each CT scan were segmented automatically and compared to the human annotations by using ratio of intersection over union (IU) as the criterion. The experimental results demonstrated the IUs of the segmentation results had a mean value of 79% and 67% by averaging 17 types of organs that segmented by a 3D- and 2D deep CNN, respectively. All the results of the deep learning approaches showed a better accuracy and robustness than the conventional segmentation method that used probabilistic atlas and graph-cut methods. The effectiveness and the usefulness of deep learning approaches were demonstrated for solving multiple organs segmentation problem on 3D CT images.

  4. Research on the Hotel Image Based on the Detail Service

    Science.gov (United States)

    Li, Ban; Shenghua, Zheng; He, Yi

    Detail service management, initially developed as marketing programs to enhance customer loyalty, has now become an important part of customer relation strategy. This paper analyzes the critical factors of detail service and its influence on the hotel image. We establish the theoretical model of influencing factors on hotel image and propose corresponding hypotheses. We use applying statistical method to test and verify the above-mentioned hypotheses. This paper provides a foundation for further study of detail service design and planning issues.

  5. Simulation Study of Real Time 3-D Synthetic Aperture Sequential Beamforming for Ultrasound Imaging

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Rasmussen, Morten Fischer; Stuart, Matthias Bo

    2014-01-01

    in the main system. The real-time imaging capability is achieved using a synthetic aperture beamforming technique, utilizing the transmit events to generate a set of virtual elements that in combination can generate an image. The two core capabilities in combination is named Synthetic Aperture Sequential......This paper presents a new beamforming method for real-time three-dimensional (3-D) ultrasound imaging using a 2-D matrix transducer. To obtain images with sufficient resolution and contrast, several thousand elements are needed. The proposed method reduces the required channel count from...... Beamforming (SASB). Simulations are performed to evaluate the image quality of the presented method in comparison to Parallel beamforming utilizing 16 receive beamformers. As indicators for image quality the detail resolution and Cystic resolution are determined for a set of scatterers at a depth of 90mm...

  6. 3D vector flow imaging

    DEFF Research Database (Denmark)

    Pihl, Michael Johannes

    The main purpose of this PhD project is to develop an ultrasonic method for 3D vector flow imaging. The motivation is to advance the field of velocity estimation in ultrasound, which plays an important role in the clinic. The velocity of blood has components in all three spatial dimensions, yet...... are (vx, vy, vz) = (-0.03, 95, 1.0) ± (9, 6, 1) cm/s compared with the expected (0, 96, 0) cm/s. Afterwards, 3D vector flow images from a cross-sectional plane of the vessel are presented. The out of plane velocities exhibit the expected 2D circular-symmetric parabolic shape. The experimental results...... verify that the 3D TO method estimates the complete 3D velocity vectors, and that the method is suitable for 3D vector flow imaging....

  7. Author Details

    African Journals Online (AJOL)

    Radwan M.D, Mona Ahmed. Vol 12, No 1 (2000) - Articles RELAPSING REMITTING MULTIPLE SCLEROSIS: CT AND MRI IMAGING VS CLINICAL FINDINGIN THE DIAGNOSIS AND DETERMINATION OF DISEASE ACTIVITY. Details. ISSN: 1110-5607. AJOL African Journals Online. HOW TO USE AJOL... for Researchers ...

  8. Effects of x-ray and CT image enhancements on the robustness and accuracy of a rigid 3D/2D image registration

    International Nuclear Information System (INIS)

    Kim, Jinkoo; Yin Fangfang; Zhao Yang; Kim, Jae Ho

    2005-01-01

    A rigid body three-dimensional/two-dimensional (3D/2D) registration method has been implemented using mutual information, gradient ascent, and 3D texturemap-based digitally reconstructed radiographs. Nine combinations of commonly used x-ray and computed tomography (CT) image enhancement methods, including window leveling, histogram equalization, and adaptive histogram equalization, were examined to assess their effects on accuracy and robustness of the registration method. From a set of experiments using an anthropomorphic chest phantom, we were able to draw several conclusions. First, the CT and x-ray preprocessing combination with the widest attraction range was the one that linearly stretched the histograms onto the entire display range on both CT and x-ray images. The average attraction ranges of this combination were 71.3 mm and 61.3 deg in the translation and rotation dimensions, respectively, and the average errors were 0.12 deg and 0.47 mm. Second, the combination of the CT image with tissue and bone information and the x-ray images with adaptive histogram equalization also showed subvoxel accuracy, especially the best in the translation dimensions. However, its attraction ranges were the smallest among the examined combinations (on average 36 mm and 19 deg). Last the bone-only information on the CT image did not show convergency property to the correct registration

  9. D3D augmented reality imaging system: proof of concept in mammography

    Directory of Open Access Journals (Sweden)

    Douglas DB

    2016-08-01

    Full Text Available David B Douglas,1 Emanuel F Petricoin,2 Lance Liotta,2 Eugene Wilson3 1Department of Radiology, Stanford University, Palo Alto, CA, 2Center for Applied Proteomics and Molecular Medicine, George Mason University, Manassas, VA, 3Department of Radiology, Fort Benning, Columbus, GA, USA Purpose: The purpose of this article is to present images from simulated breast microcalcifications and assess the pattern of the microcalcifications with a technical development called “depth 3-dimensional (D3D augmented reality”. Materials and methods: A computer, head display unit, joystick, D3D augmented reality software, and an in-house script of simulated data of breast microcalcifications in a ductal distribution were used. No patient data was used and no statistical analysis was performed. Results: The D3D augmented reality system demonstrated stereoscopic depth perception by presenting a unique image to each eye, focal point convergence, head position tracking, 3D cursor, and joystick fly-through. Conclusion: The D3D augmented reality imaging system offers image viewing with depth perception and focal point convergence. The D3D augmented reality system should be tested to determine its utility in clinical practice. Keywords: augmented reality, 3D medical imaging, radiology, depth perception

  10. Measurement of left atrial volume by 2D and 3D non-contrast computed tomography compared with cardiac magnetic resonance imaging

    DEFF Research Database (Denmark)

    Fredgart, Maise Høigaard; Carter-Storch, Rasmus; Møller, Jacob Eifer

    2018-01-01

    Background: Cardiac magnetic resonance imaging (MRI) is considered the gold standard for assessment of left atrial (LA) volume. We assessed the feasibility of evaluating LA volume using 3D non-contrast computed tomography (NCCT). Furthermore, since manual tracing of LA volume is time consuming, we...... evaluated the accuracy of the LA area using 2D NCCT imaging for LA volume assessment. Methods: MRI and NCCT imaging were performed in 69 patients before and one year after aortic valve replacement. In 3D MRI and 3D NCCT, each slice was manually traced, excluding the pulmonary veins and atrial appendage...

  11. Effects of intra-operative fluoroscopic 3D-imaging on peri-operative imaging strategy in calcaneal fracture surgery.

    Science.gov (United States)

    Beerekamp, M S H; Backes, M; Schep, N W L; Ubbink, D T; Luitse, J S; Schepers, T; Goslings, J C

    2017-12-01

    Previous studies demonstrated that intra-operative fluoroscopic 3D-imaging (3D-imaging) in calcaneal fracture surgery is promising to prevent revision surgery and save costs. However, these studies limited their focus to corrections performed after 3D-imaging, thereby neglecting corrections after intra-operative fluoroscopic 2D-imaging (2D-imaging). The aim of this study was to assess the effects of additional 3D-imaging on intra-operative corrections, peri-operative imaging used, and patient-relevant outcomes compared to 2D-imaging alone. In this before-after study, data of adult patients who underwent open reduction and internal fixation (ORIF) of a calcaneal fracture between 2000 and 2014 in our level-I Trauma center were collected. 3D-imaging (BV Pulsera with 3D-RX, Philips Healthcare, Best, The Netherlands) was available as of 2007 at the surgeons' discretion. Patient and fracture characteristics, peri-operative imaging, intra-operative corrections and patient-relevant outcomes were collected from the hospital databases. Patients in whom additional 3D-imaging was applied were compared to those undergoing 2D-imaging alone. A total of 231 patients were included of whom 107 (46%) were operated with the use of 3D-imaging. No significant differences were found in baseline characteristics. The median duration of surgery was significantly longer when using 3D-imaging (2:08 vs. 1:54 h; p = 0.002). Corrections after additional 3D-imaging were performed in 53% of the patients. However, significantly fewer corrections were made after 2D-imaging when 3D-imaging was available (Risk difference (RD) -15%; 95% Confidence interval (CI) -29 to -2). Peri-operative imaging, besides intra-operative 3D-imaging, and patient-relevant outcomes were similar between groups. Intra-operative 3D-imaging provides additional information resulting in additional corrections. Moreover, 3D-imaging probably changed the surgeons' attitude to rely more on 3D-imaging, hence a 15%-decrease of

  12. 2D Doppler backscattering using synthetic aperture microwave imaging of MAST edge plasmas

    Science.gov (United States)

    Thomas, D. A.; Brunner, K. J.; Freethy, S. J.; Huang, B. K.; Shevchenko, V. F.; Vann, R. G. L.

    2016-02-01

    Doppler backscattering (DBS) is already established as a powerful diagnostic; its extension to 2D enables imaging of turbulence characteristics from an extended region of the cut-off surface. The Synthetic Aperture Microwave Imaging (SAMI) diagnostic has conducted proof-of-principle 2D DBS experiments of MAST edge plasma. SAMI actively probes the plasma edge using a wide (±40° vertical and horizontal) and tuneable (10-34.5 GHz) beam. The Doppler backscattered signal is digitised in vector form using an array of eight Vivaldi PCB antennas. This allows the receiving array to be focused in any direction within the field of view simultaneously to an angular range of 6-24° FWHM at 10-34.5 GHz. This capability is unique to SAMI and is a novel way of conducting DBS experiments. In this paper the feasibility of conducting 2D DBS experiments is explored. Initial observations of phenomena previously measured by conventional DBS experiments are presented; such as momentum injection from neutral beams and an abrupt change in power and turbulence velocity coinciding with the onset of H-mode. In addition, being able to carry out 2D DBS imaging allows a measurement of magnetic pitch angle to be made; preliminary results are presented. Capabilities gained through steering a beam using a phased array and the limitations of this technique are discussed.

  13. Nonlaser-based 3D surface imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Shin-yee; Johnson, R.K.; Sherwood, R.J. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    3D surface imaging refers to methods that generate a 3D surface representation of objects of a scene under viewing. Laser-based 3D surface imaging systems are commonly used in manufacturing, robotics and biomedical research. Although laser-based systems provide satisfactory solutions for most applications, there are situations where non laser-based approaches are preferred. The issues that make alternative methods sometimes more attractive are: (1) real-time data capturing, (2) eye-safety, (3) portability, and (4) work distance. The focus of this presentation is on generating a 3D surface from multiple 2D projected images using CCD cameras, without a laser light source. Two methods are presented: stereo vision and depth-from-focus. Their applications are described.

  14. Application of a logistic function to the analysis of contrast-detail curves

    International Nuclear Information System (INIS)

    Mumma, C.G.; Prince, J.R.

    1987-01-01

    A general logistic function has been applied to the regression analysis of radioscintigraphic contrast-detail (CD) curves obtained in the authors' laboratory and to previously published results in assorted imaging modalities. Regression analysis is based on the logistic function: d/sub min/ = d/sub min//sup sat/(1 - EXP - (K + CX)), where d/sub min/ is the minimum perceptible detail diameter at a primary contrast X, and d/sub min//sup sat/ is the saturation value of d/sub min/. K and C are regression parameters. Logistic regression in assorted imaging modalities yielded r 2 values ranging from 0.95 to 0.99. A figure of merit (FOM), the area under the CD curve (AUC), is obtained by integrating the logistic function over mathematically and clinically acceptable limits. For count densities of 200 countscm 2 and 1,000 countscm 2 , the AUC differed approximately by a factor of 2. Thus, the AUC may be a sensitive FOM

  15. A quantitative damage imaging technique based on enhanced CCRTM for composite plates using 2D scan

    Science.gov (United States)

    He, Jiaze; Yuan, Fuh-Gwo

    2016-10-01

    A two-dimensional (2D) non-contact areal scan system was developed to image and quantify impact damage in a composite plate using an enhanced zero-lag cross-correlation reverse-time migration (E-CCRTM) technique. The system comprises a single piezoelectric wafer mounted on the composite plate and a laser Doppler vibrometer (LDV) for scanning a region in the vicinity of the PZT to capture the scattered wavefield. The proposed damage imaging technique takes into account the amplitude, phase, geometric spreading, and all of the frequency content of the Lamb waves propagating in the plate; thus, a reflectivity coefficients of the delamination is calculated and potentially related to damage severity. Comparisons are made in terms of damage imaging quality between 2D areal scans and 1D line scans as well as between the proposed and existing imaging conditions. The experimental results show that the 2D E-CCRTM performs robustly when imaging and quantifying impact damage in large-scale composites using a single PZT actuator with a nearby areal scan using LDV.

  16. Geological Structures Mapping of Bukit Bunuh using 2-D Resistivity Imaging Method

    Science.gov (United States)

    Nur Amalina, M. K. A.; Nordiana, M. M.; Rahman, Nazrin; Saidin, Mokhtar; Masnan, S. S. K.

    2018-04-01

    The geological area of Bukit Bunuh is very complex due to the meteorite impact that has occurred millions years ago at Lenggong, Perak. The lithology of the study area consists of alluvium, tephra dust, and granitic rock. The geological contact, fault and fracture zone were found at the study area may indicate the geological process that undergoes at a place locally or regionally. These important features have led to the further research on 2-D resistivity imaging method (2-D RIM) to study the geological features. This method can provide the subsurface image that will delineate the geological structures. The surveys include three separate lines of different length which depend on the accessibility. The surveys were done by using Pole-Dipole array and 10 m of electrodes spacing. The objectives of this research are to determine the subsurface geological contact and to determine the existence of fault/fracture zones at the contact zone. The results from 2-D inversion profiles have successfully signified the types of geological structural such as fault, contact, and fractures. Hence, the results from 2-D RIM were used to draw the geological lineaments of Bukit Bunuh. The discontinuity of the lineaments may indicate the structures present.

  17. Surface topography characterization using 3D stereoscopic reconstruction of SEM images

    Science.gov (United States)

    Vedantha Krishna, Amogh; Flys, Olena; Reddy, Vijeth V.; Rosén, B. G.

    2018-06-01

    A major drawback of the optical microscope is its limitation to resolve finer details. Many microscopes have been developed to overcome the limitations set by the diffraction of visible light. The scanning electron microscope (SEM) is one such alternative: it uses electrons for imaging, which have much smaller wavelength than photons. As a result high magnification with superior image resolution can be achieved. However, SEM generates 2D images which provide limited data for surface measurements and analysis. Often many research areas require the knowledge of 3D structures as they contribute to a comprehensive understanding of microstructure by allowing effective measurements and qualitative visualization of the samples under study. For this reason, stereo photogrammetry technique is employed to convert SEM images into 3D measurable data. This paper aims to utilize a stereoscopic reconstruction technique as a reliable method for characterization of surface topography. Reconstructed results from SEM images are compared with coherence scanning interferometer (CSI) results obtained by measuring a roughness reference standard sample. This paper presents a method to select the most robust/consistent surface texture parameters that are insensitive to the uncertainties involved in the reconstruction technique itself. Results from the two-stereoscopic reconstruction algorithms are also documented in this paper.

  18. Imaging the motion of electrons in 2D semiconductor heterostructures

    Science.gov (United States)

    Dani, Keshav

    Technological progress since the late 20th century has centered on semiconductor devices, such as transistors, diodes, and solar cells. At the heart of these devices, is the internal motion of electrons through semiconductor materials due to applied electric fields or by the excitation of photocarriers. Imaging the motion of these electrons would provide unprecedented insight into this important phenomenon, but requires high spatial and temporal resolution. Current studies of electron dynamics in semiconductors are generally limited by the spatial resolution of optical probes, or by the temporal resolution of electronic probes. In this talk, we combine femtosecond pump-probe techniques with spectroscopic photoemission electron microscopy to image the motion of photoexcited electrons from high-energy to low-energy states in a 2D InSe/GaAs heterostructure exhibiting a type-II band alignment. At the instant of photoexcitation, energy-resolved photoelectron images reveal a highly non-equilibrium distribution of photocarriers in space and energy. Thereafter, in response to the out-of-equilibrium photocarriers, we observe the spatial redistribution of charges, thus forming internal electric fields, bending the semiconductor bands, and finally impeding further charge transfer. By assembling images taken at different time-delays, we make a movie lasting a few tens of picoseconds of the electron transfer process in the photoexcited type-II heterostructure - a fundamental phenomenon in semiconductor devices like solar cells. Quantitative analysis and theoretical modeling of spatial variations in the video provide insight into future solar cells, electron dynamics in 2D materials, and other semiconductor devices.

  19. Registration of dynamic dopamine D{sub 2}receptor images using principal component analysis

    Energy Technology Data Exchange (ETDEWEB)

    Acton, P.D.; Ell, P.J. [Institute of Nuclear Medicine, University College London Medical School, London (United Kingdom); Pilowsky, L.S.; Brammer, M.J. [Institute of Psychiatry, De Crespigny Park, London (United Kingdom); Suckling, J. [Clinical Age Research Unit, Kings College School of Medicine and Dentistry, London (United Kingdom)

    1997-11-01

    This paper describes a novel technique for registering a dynamic sequence of single-photon emission tomography (SPET) dopamine D{sub 2}receptor images, using principal component analysis (PCA). Conventional methods for registering images, such as count difference and correlation coefficient algorithms, fail to take into account the dynamic nature of the data, resulting in large systematic errors when registering time-varying images. However, by using principal component analysis to extract the temporal structure of the image sequence, misregistration can be quantified by examining the distribution of eigenvalues. The registration procedures were tested using a computer-generated dynamic phantom derived from a high-resolution magnetic resonance image of a realistic brain phantom. Each method was also applied to clinical SPET images of dopamine D {sub 2}receptors, using the ligands iodine-123 iodobenzamide and iodine-123 epidepride, to investigate the influence of misregistration on kinetic modelling parameters and the binding potential. The PCA technique gave highly significant (P <0.001) improvements in image registration, leading to alignment errors in x and y of about 25% of the alternative methods, with reductions in autocorrelations over time. It could also be applied to align image sequences which the other methods failed completely to register, particularly {sup 123}I-epidepride scans. The PCA method produced data of much greater quality for subsequent kinetic modelling, with an improvement of nearly 50% in the {chi}{sup 2}of the fit to the compartmental model, and provided superior quality registration of particularly difficult dynamic sequences. (orig.) With 4 figs., 2 tabs., 26 refs.

  20. A Method for Interactive 3D Reconstruction of Piecewise Planar Objects from Single Images

    OpenAIRE

    Sturm , Peter; Maybank , Steve

    1999-01-01

    International audience; We present an approach for 3D reconstruction of objects from a single image. Obviously, constraints on the 3D structure are needed to perform this task. Our approach is based on user-provided coplanarity, perpendicularity and parallelism constraints. These are used to calibrate the image and perform 3D reconstruction. The method is described in detail and results are provided.

  1. Comparison of post-contrast 3D-T1-MPRAGE, 3D-T1-SPACE and 3D-T2-FLAIR MR images in evaluation of meningeal abnormalities at 3-T MRI.

    Science.gov (United States)

    Jeevanandham, Balaji; Kalyanpur, Tejas; Gupta, Prashant; Cherian, Mathew

    2017-06-01

    This study was to assess the usefulness of newer three-dimensional (3D)-T 1 sampling perfection with application optimized contrast using different flip-angle evolutions (SPACE) and 3D-T 2 fluid-attenuated inversion recovery (FLAIR) sequences in evaluation of meningeal abnormalities. 78 patients who presented with high suspicion of meningeal abnormalities were evaluated using post-contrast 3D-T 2 -FLAIR, 3D-T 1 magnetization-prepared rapid gradient-echo (MPRAGE) and 3D-T 1 -SPACE sequences. The images were evaluated independently by two radiologists for cortical gyral, sulcal space, basal cisterns and dural enhancement. The diagnoses were confirmed by further investigations including histopathology. Post-contrast 3D-T 1 -SPACE and 3D-T 2 -FLAIR images yielded significantly more information than MPRAGE images (p evaluation of meningeal abnormalities and when used in combination have the maximum sensitivity for leptomeningeal abnormalities. The negative-predictive value is nearly 100%, where no leptomeningeal abnormality was detected on these sequences. Advances in knowledge: Post-contrast 3D-T 1 -SPACE and 3D-T 2 -FLAIR images are more useful than 3D-T 1 -MPRAGE images in evaluation of meningeal abnormalities.

  2. Patient-specific estimation of detailed cochlear shape from clinical CT images

    DEFF Research Database (Denmark)

    Kjer, H Martin; Fagertun, Jens; Wimmer, Wilhelm

    2018-01-01

    of the detailed patient-specific cochlear shape from CT images. From a collection of temporal bone [Formula: see text]CT images, we build a cochlear statistical deformation model (SDM), which is a description of how a human cochlea deforms to represent the observed anatomical variability. The model is used...... for regularization of a non-rigid image registration procedure between a patient CT scan and a [Formula: see text]CT image, allowing us to estimate the detailed patient-specific cochlear shape. We test the accuracy and precision of the predicted cochlear shape using both [Formula: see text]CT and CT images...

  3. Time-resolved diffusion tomographic 2D and 3D imaging in highly scattering turbid media

    Science.gov (United States)

    Alfano, Robert R. (Inventor); Cai, Wei (Inventor); Gayen, Swapan K. (Inventor)

    2000-01-01

    A method for imaging objects in highly scattering turbid media. According to one embodiment of the invention, the method involves using a plurality of intersecting source/detectors sets and time-resolving equipment to generate a plurality of time-resolved intensity curves for the diffusive component of light emergent from the medium. For each of the curves, the intensities at a plurality of times are then inputted into the following inverse reconstruction algorithm to form an image of the medium: wherein W is a matrix relating output at source and detector positions r.sub.s and r.sub.d, at time t, to position r, .LAMBDA. is a regularization matrix, chosen for convenience to be diagonal, but selected in a way related to the ratio of the noise, to fluctuations in the absorption (or diffusion) X.sub.j that we are trying to determine: .LAMBDA..sub.ij =.lambda..sub.j .delta..sub.ij with .lambda..sub.j =/ Y is the data collected at the detectors, and X.sup.k is the kth iterate toward the desired absorption information. An algorithm, which combines a two dimensional (2D) matrix inversion with a one-dimensional (1D) Fourier transform inversion is used to obtain images of three dimensional hidden objects in turbid scattering media.

  4. Multi-stage 3D-2D registration for correction of anatomical deformation in image-guided spine surgery

    Science.gov (United States)

    Ketcha, M. D.; De Silva, T.; Uneri, A.; Jacobson, M. W.; Goerres, J.; Kleinszig, G.; Vogt, S.; Wolinsky, J.-P.; Siewerdsen, J. H.

    2017-06-01

    A multi-stage image-based 3D-2D registration method is presented that maps annotations in a 3D image (e.g. point labels annotating individual vertebrae in preoperative CT) to an intraoperative radiograph in which the patient has undergone non-rigid anatomical deformation due to changes in patient positioning or due to the intervention itself. The proposed method (termed msLevelCheck) extends a previous rigid registration solution (LevelCheck) to provide an accurate mapping of vertebral labels in the presence of spinal deformation. The method employs a multi-stage series of rigid 3D-2D registrations performed on sets of automatically determined and increasingly localized sub-images, with the final stage achieving a rigid mapping for each label to yield a locally rigid yet globally deformable solution. The method was evaluated first in a phantom study in which a CT image of the spine was acquired followed by a series of 7 mobile radiographs with increasing degree of deformation applied. Second, the method was validated using a clinical data set of patients exhibiting strong spinal deformation during thoracolumbar spine surgery. Registration accuracy was assessed using projection distance error (PDE) and failure rate (PDE  >  20 mm—i.e. label registered outside vertebra). The msLevelCheck method was able to register all vertebrae accurately for all cases of deformation in the phantom study, improving the maximum PDE of the rigid method from 22.4 mm to 3.9 mm. The clinical study demonstrated the feasibility of the approach in real patient data by accurately registering all vertebral labels in each case, eliminating all instances of failure encountered in the conventional rigid method. The multi-stage approach demonstrated accurate mapping of vertebral labels in the presence of strong spinal deformation. The msLevelCheck method maintains other advantageous aspects of the original LevelCheck method (e.g. compatibility with standard clinical workflow, large

  5. Mvox: Interactive 2-4D medical image and graphics visualization software

    DEFF Research Database (Denmark)

    Bro-Nielsen, Morten

    1996-01-01

    Mvox is a new tool for visualization, segmentation and manipulation of a wide range of 2-4D grey level and colour images, and 3D surface graphics, which has been developed at the Department of Mathematical Modelling, Technical University of Denmark. The principal idea behind the software has been...... to provide a flexible tool that is able to handle all the kinds of data that are typically used in a research environment for medical imaging and visualization. At the same time the software should be easy to use and have a consistent interface providing locally only the functions relevant to the context....... This has been achieved by using Unix standards such as X/Motif/OpenGL and conforming to modern standards of interactive windowed programs...

  6. Coupling 2D/3D registration method and statistical model to perform 3D reconstruction from partial x-rays images data.

    Science.gov (United States)

    Cresson, T; Chav, R; Branchaud, D; Humbert, L; Godbout, B; Aubert, B; Skalli, W; De Guise, J A

    2009-01-01

    3D reconstructions of the spine from a frontal and sagittal radiographs is extremely challenging. The overlying features of soft tissues and air cavities interfere with image processing. It is also difficult to obtain information that is accurate enough to reconstruct complete 3D models. To overcome these problems, the proposed method efficiently combines the partial information contained in two images from a patient with a statistical 3D spine model generated from a database of scoliotic patients. The algorithm operates through two simultaneous iterating processes. The first one generates a personalized vertebra model using a 2D/3D registration process with bone boundaries extracted from radiographs, while the other one infers the position and the shape of other vertebrae from the current estimation of the registration process using a statistical 3D model. Experimental evaluations have shown good performances of the proposed approach in terms of accuracy and robustness when compared to CT-scan.

  7. Preliminary examples of 3D vector flow imaging

    DEFF Research Database (Denmark)

    Pihl, Michael Johannes; Stuart, Matthias Bo; Tomov, Borislav Gueorguiev

    2013-01-01

    This paper presents 3D vector flow images obtained using the 3D Transverse Oscillation (TO) method. The method employs a 2D transducer and estimates the three velocity components simultaneously, which is important for visualizing complex flow patterns. Data are acquired using the experimental ult...... as opposed to magnetic resonance imaging (MRI). The results demonstrate that the 3D TO method is capable of performing 3D vector flow imaging.......This paper presents 3D vector flow images obtained using the 3D Transverse Oscillation (TO) method. The method employs a 2D transducer and estimates the three velocity components simultaneously, which is important for visualizing complex flow patterns. Data are acquired using the experimental...... ultrasound scanner SARUS on a flow rig system with steady flow. The vessel of the flow-rig is centered at a depth of 30 mm, and the flow has an expected 2D circular-symmetric parabolic prole with a peak velocity of 1 m/s. Ten frames of 3D vector flow images are acquired in a cross-sectional plane orthogonal...

  8. 3D-printing of undisturbed soil imaged by X-ray

    Science.gov (United States)

    Bacher, Matthias; Koestel, John; Schwen, Andreas

    2014-05-01

    The unique pore structures in Soils are altered easily by water flow. Each sample has a different morphology and the results of repetitions vary as well. Soil macropores in 3D-printed durable material avoid erosion and have a known morphology. Therefore potential and limitations of reproducing an undisturbed soil sample by 3D-printing was evaluated. We scanned an undisturbed soil column of Ultuna clay soil with a diameter of 7 cm by micro X-ray computer tomography at a resolution of 51 micron. A subsample cube of 2.03 cm length with connected macropores was cut out from this 3D-image and printed in five different materials by a 3D-printing service provider. The materials were ABS, Alumide, High Detail Resin, Polyamide and Prime Grey. The five print-outs of the subsample were tested on their hydraulic conductivity by using the falling head method. The hydrophobicity was tested by an adapted sessile drop method. To determine the morphology of the print-outs and compare it to the real soil also the print-outs were scanned by X-ray. The images were analysed with the open source program ImageJ. The five 3D-image print-outs copied from the subsample of the soil column were compared by means of their macropore network connectivity, porosity, surface volume, tortuosity and skeleton. The comparison of pore morphology between the real soil and the print-outs showed that Polyamide reproduced the soil macropore structure best while Alumide print-out was the least detailed. Only the largest macropore was represented in all five print-outs. Printing residual material or printing aid material remained in and clogged the pores of all print-out materials apart from Prime Grey. Therefore infiltration was blocked in these print-outs and the materials are not suitable even though the 3D-printed pore shapes were well reproduced. All of the investigated materials were insoluble. The sessile drop method showed angles between 53 and 85 degrees. Prime Grey had the fastest flow rate; the

  9. Utility of 3D Reconstruction of 2D Liver Computed Tomography/Magnetic Resonance Images as a Surgical Planning Tool for Residents in Liver Resection Surgery.

    Science.gov (United States)

    Yeo, Caitlin T; MacDonald, Andrew; Ungi, Tamas; Lasso, Andras; Jalink, Diederick; Zevin, Boris; Fichtinger, Gabor; Nanji, Sulaiman

    A fundamental aspect of surgical planning in liver resections is the identification of key vessel tributaries to preserve healthy liver tissue while fully resecting the tumor(s). Current surgical planning relies primarily on the surgeon's ability to mentally reconstruct 2D computed tomography/magnetic resonance (CT/MR) images into 3D and plan resection margins. This creates significant cognitive load, especially for trainees, as it relies on image interpretation, anatomical and surgical knowledge, experience, and spatial sense. The purpose of this study is to determine if 3D reconstruction of preoperative CT/MR images will assist resident-level trainees in making appropriate operative plans for liver resection surgery. Ten preoperative patient CT/MR images were selected. Images were case-matched, 5 to 2D planning and 5 to 3D planning. Images from the 3D group were segmented to create interactive digital models that the resident can manipulate to view the tumor(s) in relation to landmark hepatic structures. Residents were asked to evaluate the images and devise a surgical resection plan for each image. The resident alternated between 2D and 3D planning, in a randomly generated order. The primary outcome was the accuracy of resident's plan compared to expert opinion. Time to devise each surgical plan was the secondary outcome. Residents completed a prestudy and poststudy questionnaire regarding their experience with liver surgery and the 3D planning software. Senior level surgical residents from the Queen's University General Surgery residency program were recruited to participate. A total of 14 residents participated in the study. The median correct response rate was 2 of 5 (40%; range: 0-4) for the 2D group, and 3 of 5 (60%; range: 1-5) for the 3D group (p surgery planning increases accuracy of resident surgical planning and decreases amount of time required. 3D reconstruction would be a useful model for improving trainee understanding of liver anatomy and surgical

  10. Quantitative imaging of D-2-hydroxyglutarate (D2HG in selected histological tissue areas by a novel bioluminescence technique

    Directory of Open Access Journals (Sweden)

    Nadine Fabienne Voelxen

    2016-03-01

    Full Text Available AbstractPatients with malignant gliomas have a poor prognosis with average survival of less than one year. Whereas in other tumor entities the characteristics of tumor metabolism are successfully used for therapeutic approaches, such developments are very rare in brain tumors, notably in gliomas. One metabolic feature characteristic of gliomas, in particular diffuse astrocytomas and oligodendroglial tumors, is the variable content of D-2-hydroxyglutarate (D2HG, a metabolite, which was discovered first in this tumor entity. D2HG is generated in large amounts due to various gain-of–function mutations in the isocitrate dehydrogenases IDH-1 and IDH-2. Meanwhile, D2HG has been detected in several other tumor entities including intrahepatic bile-duct cancer, chondrosarcoma, acute myeloid leukemia, and angioimmunoblastic T-cell lymphoma. D2HG is barely detectable in healthy tissue (< 0.1 mM, but its concentration increases up to 35 mM in malignant tumor tissues. Consequently, the oncometabolite D2HG has gained increasing interest in the field of tumor metabolism. To facilitate its quantitative measurement without loss of spatial resolution at a microscopical level, we have developed a novel bioluminescence assay for determining D2HG in sections of snap-frozen tissue. The assay was verified independently by photometric tests and liquid chromatography / mass spectrometry (LC/MS. The novel technique allows the microscopically resolved determination of D2HG in a concentration range of 0 – 10 µmol/g tissue (wet weight. In combination with the already established bioluminescence imaging techniques for ATP, glucose, pyruvate, and lactate, the novel D2HG assay enables a comparative characterization of the metabolic profile of individual tumors in a further dimension.

  11. High-resolution 3D X-ray imaging of intracranial nitinol stents

    International Nuclear Information System (INIS)

    Snoeren, Rudolph M.; With, Peter H.N. de; Soederman, Michael; Kroon, Johannes N.; Roijers, Ruben B.; Babic, Drazenko

    2012-01-01

    To assess an optimized 3D imaging protocol for intracranial nitinol stents in 3D C-arm flat detector imaging. For this purpose, an image quality simulation and an in vitro study was carried out. Nitinol stents of various brands were placed inside an anthropomorphic head phantom, using iodine contrast. Experiments with objects were preceded by image quality and dose simulations. We varied X-ray imaging parameters in a commercially interventional X-ray system to set 3D image quality in the contrast-noise-sharpness space. Beam quality was varied to evaluate contrast of the stents while keeping absorbed dose below recommended values. Two detector formats were used, paired with an appropriate pixel size and X-ray focus size. Zoomed reconstructions were carried out and snapshot images acquired. High contrast spatial resolution was assessed with a CT phantom. We found an optimal protocol for imaging intracranial nitinol stents. Contrast resolution was optimized for nickel-titanium-containing stents. A high spatial resolution larger than 2.1 lp/mm allows struts to be visualized. We obtained images of stents of various brands and a representative set of images is shown. Independent of the make, struts can be imaged with virtually continuous strokes. Measured absorbed doses are shown to be lower than 50 mGy Computed Tomography Dose Index (CTDI). By balancing the modulation transfer of the imaging components and tuning the high-contrast imaging capabilities, we have shown that thin nitinol stent wires can be reconstructed with high contrast-to-noise ratio and good detail, while keeping radiation doses within recommended values. Experimental results compare well with imaging simulations. (orig.)

  12. Studying Axon-Astrocyte Functional Interactions by 3D Two-Photon Ca2+ Imaging: A Practical Guide to Experiments and "Big Data" Analysis.

    Science.gov (United States)

    Savtchouk, Iaroslav; Carriero, Giovanni; Volterra, Andrea

    2018-01-01

    Recent advances in fast volumetric imaging have enabled rapid generation of large amounts of multi-dimensional functional data. While many computer frameworks exist for data storage and analysis of the multi-gigabyte Ca 2+ imaging experiments in neurons, they are less useful for analyzing Ca 2+ dynamics in astrocytes, where transients do not follow a predictable spatio-temporal distribution pattern. In this manuscript, we provide a detailed protocol and commentary for recording and analyzing three-dimensional (3D) Ca 2+ transients through time in GCaMP6f-expressing astrocytes of adult brain slices in response to axonal stimulation, using our recently developed tools to perform interactive exploration, filtering, and time-correlation analysis of the transients. In addition to the protocol, we release our in-house software tools and discuss parameters pertinent to conducting axonal stimulation/response experiments across various brain regions and conditions. Our software tools are available from the Volterra Lab webpage at https://wwwfbm.unil.ch/dnf/group/glia-an-active-synaptic-partner/member/volterra-andrea-volterra in the form of software plugins for Image J (NIH)-a de facto standard in scientific image analysis. Three programs are available: MultiROI_TZ_profiler for interactive graphing of several movable ROIs simultaneously, Gaussian_Filter5D for Gaussian filtering in several dimensions, and Correlation_Calculator for computing various cross-correlation parameters on voxel collections through time.

  13. Quantitative Comparison of 2D and 3D MRI Techniques for the Evaluation of Chondromalacia Patellae in 3.0T MR Imaging of the Knee

    Directory of Open Access Journals (Sweden)

    Ali Özgen

    2016-09-01

    Full Text Available INTRODUCTION: Chondromalacia patellae is a very common disorder of patellar cartilage. Magnetic resonance imaging (MRI is a powerful non-invasive tool to investigate patellar cartilage lesions. Although many MRI sequences have been used in MR imaging of the patellar cartilage and the optimal pulse sequence is controversial, fat-saturated proton density images have been considered very valuable to evaluate patellar cartilage. The purpose of this study is to quantitatively compare the diagnostic performance of various widely used 2D and 3D MRI techniques for the evaluation of chondromalacia patellae in 3.0T MR imaging of the knee using T2 mapping images as the reference standard. METHODS: Sevety-five knee MRI exams of 69 adult consecutive were included in the study. Fat-saturated T2-weighted (FST2, fat-saturated proton density (FSPD, water-only T2-weighted DIXON (T2mD, T2-weighted 3 dimensional steady state (3DT2FFE, merged multi-echo steady state (3DmFFE, and water selective T1-weighted fat-supressed (WATSc images were acquired. Quantitative comparison of grade 1 and grade 5 lesions were made using contrast-to-noise (CNR ratios. Grade 2-4 lesions were scored qualitatively and scorings of the lesions were compared statistically. Analysis of variance and Tukey’s tests were used to compare CNR data. Two sample z-test was used to compare the ratio of MR exams positive for grade 1 lesions noted on T2-mapping and other conventional sequences. Paired samples t-test was used to compare two different pulse sequences. RESULTS: In detecting grade 1 lesions, FSPD, FST2 and T2mD images were superior in comparison to other sequences. FSPD and FST2 images were statistically superior in detecting grade 2-4 lesions. Although all grade 5 lesions were noted in every single sequence, FST2 images have the highest mean CNR followed by 3DT2FFE images. DISCUSSION AND CONCLUSION: FST2 sequence is equal or superior in detecting every grade of patellar chondromalacia in

  14. 2D-Driven 3D Object Detection in RGB-D Images

    KAUST Repository

    Lahoud, Jean; Ghanem, Bernard

    2017-01-01

    In this paper, we present a technique that places 3D bounding boxes around objects in an RGB-D scene. Our approach makes best use of the 2D information to quickly reduce the search space in 3D, benefiting from state-of-the-art 2D object detection

  15. A novel approach for a 2D/3D image registration routine for medical tool navigation in minimally invasive vascular interventions

    Energy Technology Data Exchange (ETDEWEB)

    Schwerter, Michael [Forschungszentrum Juelich (Germany). Inst. of Neuroscience and Medicine (INM-4) - Medical Imaging Physics; Lietzmann, Florian; Schad, Lothar R. [Heidelberg Univ., Medical Faculty Mannheim (Germany). Computer Assisted Clinical Medicine

    2016-11-01

    Minimally invasive interventions are frequently aided by 2D projective image guidance. To facilitate the navigation of medical tools within the patient, information from preoperative 3D images can supplement interventional data. This work describes a novel approach to perform a 3D CT data registration to a single interventional native fluoroscopic frame. The goal of this procedure is to recover and visualize a current 2D interventional tool position in its corresponding 3D dataset. A dedicated routine was developed and tested on a phantom. The 3D position of a guidewire inserted into the phantom could successfully be reconstructed for varying 2D image acquisition geometries. The scope of the routine includes projecting the CT data into the plane of the fluoroscopy. A subsequent registration of the real and virtual projections is performed with an accuracy within the range of 1.16 ± 0.17 mm for fixed landmarks. The interventional tool is extracted from the fluoroscopy and matched to the corresponding part of the projected and transformed arterial vasculature. A root mean square error of up to 0.56 mm for matched point pairs is reached. The desired 3D view is provided by backprojecting the matched guidewire through the CT array. Due to its potential to reduce patient dose and treatment times, the proposed routine has the capability of reducing patient stress at lower overall treatment costs.

  16. Image analysis and 2D/3D modeling of the MOX fuel microstructure

    International Nuclear Information System (INIS)

    Oudinet, Ghislain

    2003-01-01

    The microstructure of the MOX fuel, made with UO_2 and PuO_2, determines his 'in pile' behavior. The french companies CEA and COGEMA are highly interested in its description by image analysis, which is the object of the present work. The segmentation algorithms described here use pictures issued from a microprobe and a SEM, to analyse the plutonium and porosity distribution in the fuel pellets. They are innovating, automated and robust enough to be used with a small data set. They have been successfully tested on different fuels, before and after irradiation. Three-dimensional informations have been computed with a genetic algorithm. The obtained 3D object size distributions allowed the modeling of many different industrial and research fuels. 3D reconstruction is accurate and stable, and provides a basis for different studies among which the study of the MOX fuel 'in pile' behavior. (author)

  17. D Model of AL Zubarah Fortress in Qatar - Terrestrial Laser Scanning VS. Dense Image Matching

    Science.gov (United States)

    Kersten, T.; Mechelke, K.; Maziull, L.

    2015-02-01

    In September 2011 the fortress Al Zubarah, built in 1938 as a typical Arabic fortress and restored in 1987 as a museum, was recorded by the HafenCity University Hamburg using terrestrial laser scanning with the IMAGER 5006h and digital photogrammetry for the Qatar Museum Authority within the framework of the Qatar Islamic Archaeology and Heritage Project. One goal of the object recording was to provide detailed 2D/3D documentation of the fortress. This was used to complete specific detailed restoration work in the recent years. From the registered laser scanning point clouds several cuttings and 2D plans were generated as well as a 3D surface model by triangle meshing. Additionally, point clouds and surface models were automatically generated from digital imagery from a Nikon D70 using the open-source software Bundler/PMVS2, free software VisualSFM, Autodesk Web Service 123D Catch beta, and low-cost software Agisoft PhotoScan. These outputs were compared with the results from terrestrial laser scanning. The point clouds and surface models derived from imagery could not achieve the same quality of geometrical accuracy as laser scanning (i.e. 1-2 cm).

  18. Template Assembly for Detailed Urban Reconstruction

    KAUST Repository

    Nan, Liangliang; Wonka, Peter; Ghanem, Bernard; Jiang, Caigui

    2015-01-01

    Structure from Motion and Multi View Stereo, and we model a set of 3D templates of facade details. Next, we optimize the initial coarse model to enforce consistency between geometry and appearance (texture images). Then, building details are reconstructed

  19. Non-destructive assay employing 2D and 3D digital radiographic imaging acquired with thermal neutrons and reactor-produced radioisotopes

    International Nuclear Information System (INIS)

    Silvani, Maria Ines; Almeida, Gevaldo Lisboa de; Lopes, Ricardo T.

    2011-01-01

    The inner structure of some objects can only be visualized by using suitable techniques, when safety reasons or expensive costs preclude the application of invasive procedures. The kind of agent rendering an object partially transparent, unveiling thus its features, depends upon the object size and composition. As a rough rule of thumb, light materials are transparent to gamma and X-rays while the heavy ones are transparent to neutrons. When, after traversing an object, they hit a proper 2-D detector, a radiograph is produced representing a convoluted cross section, called projection, of that object. Taking a large number of such projections for different object attitudes, it is possible to obtain a 3-D tomography of the object as a map of attenuation coefficients. This procedure however, besides a time-consuming task, requires specially tailored equipment and software, not always available or affordable. Yet, in some circumstances it is feasible to replace the 3-D tomography by a stereoscopy, allowing one to visualize the spatial configuration of the object under analysis. In this work, 2-D and 3-D radiographic images have been acquired using thermal neutrons and reactor-produced radioisotopes and proper imaging plates as detectors. The stereographic vision has been achieved by taking two radiographs of the same object at different angles, from the detector point of view. After a treatment to render them red-white and green-white they were properly merged to yield a single image capable to be watched with red-green glasses. All the image treatment and rendering has been performed with the software ImageJ. (author)

  20. Least-square NUFFT methods applied to 2-D and 3-D radially encoded MR image reconstruction.

    Science.gov (United States)

    Song, Jiayu; Liu, Yanhui; Gewalt, Sally L; Cofer, Gary; Johnson, G Allan; Liu, Qing Huo

    2009-04-01

    Radially encoded MRI has gained increasing attention due to its motion insensitivity and reduced artifacts. However, because its samples are collected nonuniformly in the k-space, multidimensional (especially 3-D) radially sampled MRI image reconstruction is challenging. The objective of this paper is to develop a reconstruction technique in high dimensions with on-the-fly kernel calculation. It implements general multidimensional nonuniform fast Fourier transform (NUFFT) algorithms and incorporates them into a k-space image reconstruction framework. The method is then applied to reconstruct from the radially encoded k-space data, although the method is applicable to any non-Cartesian patterns. Performance comparisons are made against the conventional Kaiser-Bessel (KB) gridding method for 2-D and 3-D radially encoded computer-simulated phantoms and physically scanned phantoms. The results show that the NUFFT reconstruction method has better accuracy-efficiency tradeoff than the KB gridding method when the kernel weights are calculated on the fly. It is found that for a particular conventional kernel function, using its corresponding deapodization function as a scaling factor in the NUFFT framework has the potential to improve accuracy. In particular, when a cosine scaling factor is used, the NUFFT method is faster than KB gridding method since a closed-form solution is available and is less computationally expensive than the KB kernel (KB griding requires computation of Bessel functions). The NUFFT method has been successfully applied to 2-D and 3-D in vivo studies on small animals.

  1. 3-D image reconstruction in radiology

    International Nuclear Information System (INIS)

    Grangeat, P.

    1999-01-01

    In this course, we present highlights on fully 3-D image reconstruction algorithms used in 3-D X-ray Computed Tomography (3-D-CT) and 3-D Rotational Radiography (3-D-RR). We first consider the case of spiral CT with a one-row detector. Starting from the 2-D fan-beam inversion formula for a circular trajectory, we introduce spiral CT 3-D image reconstruction algorithm using axial interpolation for each transverse slice. In order to improve the X-ray detection efficiency and to speed the acquisition process, the future is to use multi-row detectors associated with small angle cone-beam geometry. The generalization of the 2-D fan-beam image reconstruction algorithm to cone beam defined direct inversion formula referred as Feldkamp's algorithm for a circular trajectory and Wang's algorithm for a spiral trajectory. However, large area detectors does exist such as Radiological Image Intensifiers or in a near future solid state detectors. To get a larger zoom effect, it defines a cone-beam geometry associated with a large aperture angle. For this case, we introduce indirect image reconstruction algorithm by plane re-binning in the Radon domain. We will present some results from a prototype MORPHOMETER device using the RADON reconstruction software. Lastly, we consider the special case of 3-D Rotational Digital Subtraction Angiography with a restricted number of views. We introduce constraint optimization algorithm using quadratic, entropic or half-quadratic constraints. Generalized ART (Algebraic Reconstruction Technique) iterative reconstruction algorithm can be derived from the Bregman algorithm. We present reconstructed vascular trees from a prototype MORPHOMETER device. (author)

  2. Multivariate cluster analysis of dynamic iodine-123 iodobenzamide SPET dopamine D2receptor images in schizophrenia

    International Nuclear Information System (INIS)

    Acton, P.D.; Pilowsky, L.S.; Costa, D.C.; Ell, P.J.

    1997-01-01

    This paper describes the application of a multivariate statistical technique to investigate striatal dopamine D 2 receptor concentrations measured by iodine-123 iodobenzamide ( 123 I-IBZM) single-photon emission tomography (SPET). This technique enables the automatic segmentation of dynamic nuclear medicine images based on the underlying time-activity curves present in the data. Once the time-activity curves have been extracted, each pixel can be mapped back on to the underlying distribution, considerably reducing image noise. Cluster analysis has been verified using computer simulations and phantom studies. The technique has been applied to SPET images of dopamine D 2 receptors in a total of 20 healthy and 20 schizophrenic volunteers (22 male, 18 female), using the ligand 123 I-IBZM. Following automatic image segmentation, the concentration of striatal dopamine D 2 receptors shows a significant left-sided asymmetry in male schizophrenics compared with male controls. The mean left-minus-right laterality index for controls is -1.52 (95% CI -3.72-0.66) and for patients 4.04 (95% CI 1.07-7.01). Analysis of variance shows a case-by-sex-by-side interaction, with F=10.01, P=0.005. We can now demonstrate that the previously observed male sex-specific D 2 receptor asymmetry in schizophrenia, which had failed to attain statistical significance, is valid. Cluster analysis of dynamic nuclear medicine studies provides a powerful tool for automatic segmentation and noise reduction of the images, removing much of the subjectivity inherent in region-of-interest analysis. The observed striatal D 2 asymmetry could reflect long hypothesized disruptions in dopamine-rich cortico-striatal-limbic circuits in schizophrenic males. (orig.). With 4 figs., 2 tabs

  3. Validity of computational hemodynamics in human arteries based on 3D time-of-flight MR angiography and 2D electrocardiogram gated phase contrast images

    Science.gov (United States)

    Yu, Huidan (Whitney); Chen, Xi; Chen, Rou; Wang, Zhiqiang; Lin, Chen; Kralik, Stephen; Zhao, Ye

    2015-11-01

    In this work, we demonstrate the validity of 4-D patient-specific computational hemodynamics (PSCH) based on 3-D time-of-flight (TOF) MR angiography (MRA) and 2-D electrocardiogram (ECG) gated phase contrast (PC) images. The mesoscale lattice Boltzmann method (LBM) is employed to segment morphological arterial geometry from TOF MRA, to extract velocity profiles from ECG PC images, and to simulate fluid dynamics on a unified GPU accelerated computational platform. Two healthy volunteers are recruited to participate in the study. For each volunteer, a 3-D high resolution TOF MRA image and 10 2-D ECG gated PC images are acquired to provide the morphological geometry and the time-varying flow velocity profiles for necessary inputs of the PSCH. Validation results will be presented through comparisons of LBM vs. 4D Flow Software for flow rates and LBM simulation vs. MRA measurement for blood flow velocity maps. Indiana University Health (IUH) Values Fund.

  4. 3D printing from diagnostic images: a radiologist's primer with an emphasis on musculoskeletal imaging-putting the 3D printing of pathology into the hands of every physician.

    Science.gov (United States)

    Friedman, Tamir; Michalski, Mark; Goodman, T Rob; Brown, J Elliott

    2016-03-01

    Three-dimensional (3D) printing has recently erupted into the medical arena due to decreased costs and increased availability of printers and software tools. Due to lack of detailed information in the medical literature on the methods for 3D printing, we have reviewed the medical and engineering literature on the various methods for 3D printing and compiled them into a practical "how to" format, thereby enabling the novice to start 3D printing with very limited funds. We describe (1) background knowledge, (2) imaging parameters, (3) software, (4) hardware, (5) post-processing, and (6) financial aspects required to cost-effectively reproduce a patient's disease ex vivo so that the patient, engineer and surgeon may hold the anatomy and associated pathology in their hands.

  5. MT2D Inversion to Image the Gorda Plate Subduction Zone

    Science.gov (United States)

    Lubis, Y. K.; Niasari, S. W.; Hartantyo, E.

    2018-04-01

    The magnetotelluric method is applicable for studying complicated geological structures because the subsurface electrical properties are strongly influenced by the electric and magnetic fields. This research located in the Gorda subduction zone beneath the North American continental plate. Magnetotelluric 2D inversion was used to image the variation of subsurface resistivity although the phase tensor analysis shows that the majority of dimensionality data is 3D. 19 MT sites were acquired from EarthScope/USArray Project. Wepresent the image of MT 2D inversion to exhibit conductivity distribution from the middle crust to uppermost asthenosphere at a depth of 120 kilometers. Based on the inversion, the overall data misfit value is 3.89. The Gorda plate subduction appears as a high resistive zone beneath the California. Local conductive features are found in the middle crust downward Klamath Mountain, Bonneville Lake, and below the eastern of Utah. Furthermore, mid-crustal is characterized by moderately resistive. Below the extensional Basin and Range province was related to highly resistive. The middle crust to the uppermost asthenosphere becomes moderately resistive. We conclude that the electrical parameters and the dimensionality of datain the shallow depth(about 22.319 km) beneath the North American platein accordance with surface geological features.

  6. An alternative approach to contrast-detail testing of X-ray image intensifier systems

    International Nuclear Information System (INIS)

    Kotre, C.J.; Marshall, N.W.; Faulkner, K.

    1992-01-01

    The difficulties of making the results of threshold contrast-detail diameter tests on X-ray image intensifier systems consistent with published performance standards are discussed. The current approach to contrast-detail testing is described and an alternative method intended to give greater consistency for all image intensifier input field diameters proposed. The current and alternative test conditions are compared on two image intensifier systems. The results obtained show that the contrast-detail curves for image intensifier systems with a wide range of input field diameters can be effectively normalized to be directly comparable to a common reference standard by applying the proposed alternative test conditions. The implications of this result on the interpretation of the contrast-detail test are discussed. (author)

  7. Initial clinical experiences with dopamine D2 receptor imaging by means of 2'-iodospiperone and single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Yonekura, Yoshiharu; Saji, Hideo; Iwasaki, Yasushi

    1995-01-01

    Dopamine D 2 receptor imaging was performed with 123 I labeled 2'-iodospiperone (2'-ISP) and single-photon emission computed tomography (SPECT) in 9 patients: 4 with idiopathic Parkinson's disease, 2 with parkinsonism, 1 with Wilson's disease and 2 with pituitary tumor, and the results were compared with the data for 9 normal subjects. Following an intravenous injection of 123 I-2'-ISP, early (within 30 min) and late (between 2 and 4 hr) SPECT images were obtained by means of a multi-detector SPECT scanner or a rotating gamma camera. In normal subjects, early SPECT images demonstrated uniform distribution of radioactivity in the cerebral gray matter and cerebellum reflecting regional cerebral blood flow, whereas late SPECT images showed high radioactivity only in the basal ganglia. All the patients with Parkinson's disease also demonstrated symmetrical basal ganglia uptake in the late SPECT images, but it was diminished in parkinsonism and Wilson's disease. One patient with a growth hormone-producing pituitary tumor had a positive uptake in the tumor. These preliminary clinical data demonstrated that 2'-ISP can be used for SPECT imaging of D 2 dopamine receptors and may be of clinical value for the diagnosis and planning of the treatment of neurological diseases. (author)

  8. Groundwater exploration using 2D Resistivity Imaging in Pagoh, Johor, Malaysia

    Science.gov (United States)

    Kadri, Muhammad; Nawawi, M. N. M.

    2010-12-01

    Groundwater is a very important component of water resources in nature. Since the demand of groundwater increases with population growth, it is necessary to explore groundwater more intensively. In Malaysia only less than 2% of the present water used is developed from groundwater. In order to determine the existence of usable groundwater for irrigation and drinking purposes in Pagoh, 2D resistivity imaging technique was utilized. The 2-D resistivity imaging technique utilized the Wenner—Schlumberger electrode array configuration because this array is moderately sensitive to both horizontal and vertical structures. Three lines were surveyed for groundwater delineation purpose The length for each survey lines are 400 meters. At Pagoh, the survey site shows the existence of groundwater. It is indicated by the resistivity values about 10-100 ohm-m. The maximum depth of investigation survey is 77 meters. In general the results show that the subsurface is made up of alluvium and clay and the high resistivity values of more than 1000 ohm-m near the surface is due laterite and the end of the depth can be interpreted as mixture of weathered material or bedrock.

  9. T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance–Guided Radiotherapy Treatment Planning

    Science.gov (United States)

    Freedman, Joshua N.; Collins, David J.; Bainbridge, Hannah; Rank, Christopher M.; Nill, Simeon; Kachelrieß, Marc; Oelfke, Uwe; Leach, Martin O.; Wetscherek, Andreas

    2017-01-01

    Objectives The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D (4D-T1w) MRI, to support treatment planning in MR-guided radiotherapy. Materials and Methods Ten patients with primary non–small cell lung cancer were scanned at 1.5 T axially with a volumetric T2-weighted turbo spin echo sequence gated to exhalation and a volumetric T1-weighted stack-of-stars spoiled gradient echo sequence with golden angle spacing acquired in free breathing. From the latter, 20 respiratory phases were reconstructed using the recently developed 4D joint MoCo-HDTV algorithm based on the self-gating signal obtained from the k-space center. Motion vector fields describing the respiratory cycle were obtained by deformable image registration between the respiratory phases and projected onto the T2-weighted image volume. The resulting 4D-T2w volumes were verified against the 4D-T1w volumes: an edge-detection method was used to measure the diaphragm positions; the locations of anatomical landmarks delineated by a radiation oncologist were compared and normalized mutual information was calculated to evaluate volumetric image similarity. Results High-resolution 4D-T2w MRI was obtained. Respiratory motion was preserved on calculated 4D-T2w MRI, with median diaphragm positions being consistent with less than 6.6 mm (2 voxels) for all patients and less than 3.3 mm (1 voxel) for 9 of 10 patients. Geometrical positions were coherent between 4D-T1w and 4D-T2w MRI as Euclidean distances between all corresponding anatomical landmarks agreed to within 7.6 mm (Euclidean distance of 2 voxels) and were below 3.8 mm (Euclidean distance of 1 voxel) for 355 of 470 pairs of anatomical landmarks. Volumetric image similarity was commensurate between 4D-T1w and 4D-T2w MRI, as mean percentage differences in normalized mutual information (calculated over all

  10. T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance-Guided Radiotherapy Treatment Planning.

    Science.gov (United States)

    Freedman, Joshua N; Collins, David J; Bainbridge, Hannah; Rank, Christopher M; Nill, Simeon; Kachelrieß, Marc; Oelfke, Uwe; Leach, Martin O; Wetscherek, Andreas

    2017-10-01

    The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D (4D-T1w) MRI, to support treatment planning in MR-guided radiotherapy. Ten patients with primary non-small cell lung cancer were scanned at 1.5 T axially with a volumetric T2-weighted turbo spin echo sequence gated to exhalation and a volumetric T1-weighted stack-of-stars spoiled gradient echo sequence with golden angle spacing acquired in free breathing. From the latter, 20 respiratory phases were reconstructed using the recently developed 4D joint MoCo-HDTV algorithm based on the self-gating signal obtained from the k-space center. Motion vector fields describing the respiratory cycle were obtained by deformable image registration between the respiratory phases and projected onto the T2-weighted image volume. The resulting 4D-T2w volumes were verified against the 4D-T1w volumes: an edge-detection method was used to measure the diaphragm positions; the locations of anatomical landmarks delineated by a radiation oncologist were compared and normalized mutual information was calculated to evaluate volumetric image similarity. High-resolution 4D-T2w MRI was obtained. Respiratory motion was preserved on calculated 4D-T2w MRI, with median diaphragm positions being consistent with less than 6.6 mm (2 voxels) for all patients and less than 3.3 mm (1 voxel) for 9 of 10 patients. Geometrical positions were coherent between 4D-T1w and 4D-T2w MRI as Euclidean distances between all corresponding anatomical landmarks agreed to within 7.6 mm (Euclidean distance of 2 voxels) and were below 3.8 mm (Euclidean distance of 1 voxel) for 355 of 470 pairs of anatomical landmarks. Volumetric image similarity was commensurate between 4D-T1w and 4D-T2w MRI, as mean percentage differences in normalized mutual information (calculated over all respiratory phases and patients), between

  11. Label-free and highly sensitive optical imaging of detailed microcirculation within meninges and cortex in mice with the cranium left intact

    Science.gov (United States)

    Jia, Yali; An, Lin; Wang, Ruikang K.

    2010-05-01

    We demonstrate for the first time that the detailed blood flow distribution within intracranial dura mater and cortex can be visualized by an ultrahigh sensitive optical microangiography (UHS-OMAG). The study uses an UHS-OMAG system operating at 1310 nm with an imaging speed at 150 frames per second that requires ~10 s to complete one 3-D scan of ~2.5×2.5 mm2. The system is sensitive to blood flow with a velocity ranging from ~4 μm/s to ~23 mm/s. We show superior performance of UHS-OMAG in providing functional images of capillary level microcirculation within meninges in mice with the cranium left intact, the results of which correlate well with the standard dural histopathology.

  12. Parametric modelling and segmentation of vertebral bodies in 3D CT and MR spine images

    International Nuclear Information System (INIS)

    Štern, Darko; Likar, Boštjan; Pernuš, Franjo; Vrtovec, Tomaž

    2011-01-01

    Accurate and objective evaluation of vertebral deformations is of significant importance in clinical diagnostics and therapy of pathological conditions affecting the spine. Although modern clinical practice is focused on three-dimensional (3D) computed tomography (CT) and magnetic resonance (MR) imaging techniques, the established methods for evaluation of vertebral deformations are limited to measuring deformations in two-dimensional (2D) x-ray images. In this paper, we propose a method for quantitative description of vertebral body deformations by efficient modelling and segmentation of vertebral bodies in 3D. The deformations are evaluated from the parameters of a 3D superquadric model, which is initialized as an elliptical cylinder and then gradually deformed by introducing transformations that yield a more detailed representation of the vertebral body shape. After modelling the vertebral body shape with 25 clinically meaningful parameters and the vertebral body pose with six rigid body parameters, the 3D model is aligned to the observed vertebral body in the 3D image. The performance of the method was evaluated on 75 vertebrae from CT and 75 vertebrae from T 2 -weighted MR spine images, extracted from the thoracolumbar part of normal and pathological spines. The results show that the proposed method can be used for 3D segmentation of vertebral bodies in CT and MR images, as the proposed 3D model is able to describe both normal and pathological vertebral body deformations. The method may therefore be used for initialization of whole vertebra segmentation or for quantitative measurement of vertebral body deformations.

  13. 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Gabbour, Maya [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Schnell, Susanne [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Jarvis, Kelly [Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Robinson, Joshua D. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Pediatrics, Division of Pediatric Cardiology, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Pediatrics, Chicago, IL (United States); Markl, Michael [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Rigsby, Cynthia K. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States)

    2015-06-15

    Doppler echocardiography (echo) is the reference standard for blood flow velocity analysis, and two-dimensional (2-D) phase-contrast magnetic resonance imaging (MRI) is considered the reference standard for quantitative blood flow assessment. However, both clinical standard-of-care techniques are limited by 2-D acquisitions and single-direction velocity encoding and may make them inadequate to assess the complex three-dimensional hemodynamics seen in congenital heart disease. Four-dimensional flow MRI (4-D flow) enables qualitative and quantitative analysis of complex blood flow in the heart and great arteries. The objectives of this study are to compare 4-D flow with 2-D phase-contrast MRI for quantification of aortic and pulmonary flow and to evaluate the advantage of 4-D flow-based volumetric flow analysis compared to 2-D phase-contrast MRI and echo for peak velocity assessment in children and young adults. Two-dimensional phase-contrast MRI of the aortic root, main pulmonary artery (MPA), and right and left pulmonary arteries (RPA, LPA) and 4-D flow with volumetric coverage of the aorta and pulmonary arteries were performed in 50 patients (mean age: 13.1 ± 6.4 years). Four-dimensional flow analyses included calculation of net flow and regurgitant fraction with 4-D flow analysis planes similarly positioned to 2-D planes. In addition, 4-D flow volumetric assessment of aortic root/ascending aorta and MPA peak velocities was performed and compared to 2-D phase-contrast MRI and echo. Excellent correlation and agreement were found between 2-D phase-contrast MRI and 4-D flow for net flow (r = 0.97, P < 0.001) and excellent correlation with good agreement was found for regurgitant fraction (r = 0.88, P < 0.001) in all vessels. Two-dimensional phase-contrast MRI significantly underestimated aortic (P = 0.032) and MPA (P < 0.001) peak velocities compared to echo, while volumetric 4-D flow analysis resulted in higher (aortic: P = 0.001) or similar (MPA: P = 0.98) peak

  14. Measurement of blood flow in the left ventricle and aorta using clinical 2D cine phase-contrast magnetic resonance imaging

    International Nuclear Information System (INIS)

    Nakamura, Masanori; Wada, Shigeo; Yokosawa, Suguru; Yamaguchi, Takami; Isoda, Haruo; Takeda, Hiroyasu

    2007-01-01

    A recent development in phase-contrast magnetic resonance imaging (cine PC-MRI) allows the detailed measurement of the blood flow in humans. The objectives of this study are twofold: to discuss the utility of clinical two-dimensional (2D) cine PC-MRI as a practical tool for analyzing hemodynamics in the aorta and left ventricle; to provide flow information at those places as references for computational fluid dynamics studies. Using 2D cine PC-MRI, we mapped velocity profiles at various cross sections of the aorta and left ventricle. The results illustrated the main flow events in the left ventricle during the cardiac cycle, such as ventricular ejection and suction, while the secondary flows were less clear. The velocity profile at the entrance of the ascending aorta appeared to be slightly skewed posteriorly in early systole, but the flow in the central zone of the section was rapid. The estimated stroke volume, peak Reynolds numbers, and Womersley numbers were within the normal physiological range. A sequence of secondary flow images from the plane of the aortic valve to the descending aorta revealed the evolution of a helical flow within the aorta. Flows entering the aortic branches were captured well. Those results demonstrate that clinical 2D cine PC-MRI is a practical adjunct for analyzing blood flow in vivo and would be useful as references to check validity of flow dynamics obtained by computer simulations. (author)

  15. A cone-beam CT based technique to augment the 3D virtual skull model with a detailed dental surface.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mommaerts, M.Y.; Abeloos, J.V.S.; Clercq, C. De; Lamoral, P.; Neyt, N.; Casselman, J.W.; Schutyser, F.A.C.

    2009-01-01

    Cone-beam computed tomography (CBCT) is used for maxillofacial imaging. 3D virtual planning of orthognathic and facial orthomorphic surgery requires detailed visualisation of the interocclusal relationship. This study aimed to introduce and evaluate the use of a double CBCT scan procedure with a

  16. Ultralow-dose CT of the craniofacial bone for navigated surgery using adaptive statistical iterative reconstruction and model-based iterative reconstruction: 2D and 3D image quality.

    Science.gov (United States)

    Widmann, Gerlig; Schullian, Peter; Gassner, Eva-Maria; Hoermann, Romed; Bale, Reto; Puelacher, Wolfgang

    2015-03-01

    OBJECTIVE. The purpose of this article is to evaluate 2D and 3D image quality of high-resolution ultralow-dose CT images of the craniofacial bone for navigated surgery using adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) in comparison with standard filtered backprojection (FBP). MATERIALS AND METHODS. A formalin-fixed human cadaver head was scanned using a clinical reference protocol at a CT dose index volume of 30.48 mGy and a series of five ultralow-dose protocols at 3.48, 2.19, 0.82, 0.44, and 0.22 mGy using FBP and ASIR at 50% (ASIR-50), ASIR at 100% (ASIR-100), and MBIR. Blinded 2D axial and 3D volume-rendered images were compared with each other by three readers using top-down scoring. Scores were analyzed per protocol or dose and reconstruction. All images were compared with the FBP reference at 30.48 mGy. A nonparametric Mann-Whitney U test was used. Statistical significance was set at p ASIR-100 at 3.48 mGy, ASIR-100 at 2.19 mGy, and MBIR at 0.82 mGy. MBIR at 2.19 and 3.48 mGy scored statistically significantly better than the FBP reference (p = 0.032 and 0.001, respectively). For 3D images, the FBP reference at 30.48 mGy did not statistically significantly differ from all reconstructions at 3.48 mGy; FBP and ASIR-100 at 2.19 mGy; FBP, ASIR-100, and MBIR at 0.82 mGy; MBIR at 0.44 mGy; and MBIR at 0.22 mGy. CONCLUSION. MBIR (2D and 3D) and ASIR-100 (2D) may significantly improve subjective image quality of ultralow-dose images and may allow more than 90% dose reductions.

  17. SPECT imaging of D2 dopamine receptors and endogenous dopamine release in mice

    International Nuclear Information System (INIS)

    Jongen, Cynthia; Bruin, Kora de; Booij, Jan; Beekman, Freek

    2008-01-01

    The dopamine D 2 receptor (D2R) is important in the mediation of addiction. [ 123 I]iodobenzamide (IBZM), a SPECT ligand for the D2R, has been used for in vivo studies of D2R availability in humans, monkeys, and rats. Although mouse models are important in the study of addiction, [ 123 I]IBZM has not been used in mice SPECT studies. This study evaluates the use of [ 123 I]IBZM for measuring D2R availability in mice. Pharmacokinetics of [ 123 I]IBZM in mice were studied with pinhole SPECT imaging after intravenous (i.v.) injection of [ 123 I]IBZM (20, 40, and 70 MBq). In addition, the ability to measure the release of endogenous dopamine after amphetamine administration with [ 123 I]IBZM SPECT was investigated. Thirdly, i.v. administration, the standard route of administration, and intraperitoneal (i.p.) administration of [ 123 I]IBZM were compared. Specific binding of [ 123 I]IBZM within the mouse striatum could be clearly visualized with SPECT. Peak specific striatal binding ratios were reached around 90 min post-injection. After amphetamine administration, the specific binding ratios of [ 123 I]IBZM decreased significantly (-27.2%; n=6; p=0.046). Intravenous administration of [ 123 I]IBZM led to significantly higher specific binding than i.p. administration of the same dose. However, we found that i.v. administration of a dose of 70 MBq [ 123 I]IBZM might result in acute ethanol intoxication because ethanol is used as a preparative aid for the routine production of [ 123 I]IBZM. Imaging of D2R availability and endogenous dopamine release in mice is feasible using [ 123 I]IBZM single pinhole SPECT. Using commercially produced [ 123 I]IBZM, a dose of 40 MBq injected i.v. can be recommended. (orig.)

  18. Three dimensional and high resolution magnetic resonance imaging of the inner ear. Normal ears and anomaly scanned with 3D-CISS sequence

    International Nuclear Information System (INIS)

    Edamatsu, Hideo; Uechi, Yoko; Honjyo, Shiro; Yamashita, Koichi; Tonami, Hisao.

    1997-01-01

    The MRI system used in this study was a new scanning sequence, 3D-CISS (Three dimensional-constructive interference in steady state) with 1.5 Tesla. Ten normal ears and one ear with Mondini type anomaly were scanned and reconstructed. In imagings of normal inner ears, the cochlea has three spiral layers; basal, middle and apical turns. Each turn was separated into three parts; the scala vestibuli, osseous spiral lamina and scala tympani. Three semicircular ducts, utricle and saccule were also reconstructed in one frame. In the inner ear of Mondini anomaly, 3D MRI showed cochlear aplasia, hypoplasia of semicircular ducts and widely dilated vestibule. The imaging was identical with findings of ''common cavity''. The anomaly was easily recognized in 3D MRI more than in 2D imagings. The detailed and cubic imagings of the Mondini anomaly in 3D MRI could not be observed with conventional 2D MRI. 3D MRI is not invasive method and can scan a target very quickly. (author)

  19. A two-step Hilbert transform method for 2D image reconstruction

    International Nuclear Information System (INIS)

    Noo, Frederic; Clackdoyle, Rolf; Pack, Jed D

    2004-01-01

    The paper describes a new accurate two-dimensional (2D) image reconstruction method consisting of two steps. In the first step, the backprojected image is formed after taking the derivative of the parallel projection data. In the second step, a Hilbert filtering is applied along certain lines in the differentiated backprojection (DBP) image. Formulae for performing the DBP step in fan-beam geometry are also presented. The advantage of this two-step Hilbert transform approach is that in certain situations, regions of interest (ROIs) can be reconstructed from truncated projection data. Simulation results are presented that illustrate very similar reconstructed image quality using the new method compared to standard filtered backprojection, and that show the capability to correctly handle truncated projections. In particular, a simulation is presented of a wide patient whose projections are truncated laterally yet for which highly accurate ROI reconstruction is obtained

  20. 3D and 4D magnetic susceptibility tomography based on complex MR images

    Science.gov (United States)

    Chen, Zikuan; Calhoun, Vince D

    2014-11-11

    Magnetic susceptibility is the physical property for T2*-weighted magnetic resonance imaging (T2*MRI). The invention relates to methods for reconstructing an internal distribution (3D map) of magnetic susceptibility values, .chi. (x,y,z), of an object, from 3D T2*MRI phase images, by using Computed Inverse Magnetic Resonance Imaging (CIMRI) tomography. The CIMRI technique solves the inverse problem of the 3D convolution by executing a 3D Total Variation (TV) regularized iterative convolution scheme, using a split Bregman iteration algorithm. The reconstruction of .chi. (x,y,z) can be designed for low-pass, band-pass, and high-pass features by using a convolution kernel that is modified from the standard dipole kernel. Multiple reconstructions can be implemented in parallel, and averaging the reconstructions can suppress noise. 4D dynamic magnetic susceptibility tomography can be implemented by reconstructing a 3D susceptibility volume from a 3D phase volume by performing 3D CIMRI magnetic susceptibility tomography at each snapshot time.

  1. Radioiodination of central nerves system dopamine D2 receptor imaging agent. IBZM preparation and preclinical study

    International Nuclear Information System (INIS)

    Lin Yansong; Lin Xiangtong; Hu Mingyang; Pan Shangren; Wang Bocheng

    1996-01-01

    To study preparation of central nerves system dopamine D2 imaging agent 131 I-IBZM and its preclinical investigation, peracetic acid was used as the oxidant for preparing radioiodinated 125 I-IBZM and 131 I-IBZM, D2 binding properties of IBZM were examined by in vitro binding saturation analysis, rat whole body and regional brain biodistribution, rat brain autoradiography and rabbit SPECT static imaging, etc. The results are: 1. The radiolabelling yields of 125 I-IBZM and 131 I-IBZM were 84.18% +- 3.06% and 78.50% +- 3.47%. The radiochemical purity were over 95% after being isolated by HPLC; and were over 90% after being isolated by organic extraction. 2. Scatchard plot of D2 receptor saturation binding analysis showed: K d = 0.53 +- 0.06 nmol/L, B max = 466.45 +- 45.88 fmol/mg protein. 3. The rat brain autoradiography and analysis showed that there was high 125 I-IBZM uptake in striatal area 2 hr after injection, the striatal/cerebellum ratio was 6.22 +- 0.48; the high 125 -IBZM uptake can be blocked by haloperidol--a special dopamine D2 receptor antagonist. 4. 131 I-IBZM rat biodistribution and rabbit SPECT planar imaging showed good initial brain uptake and retention, the initial uptake of rat brain was 1.893 +- 0.147% ID/g at 2 min and 1.044 +- 0.135% ID/g at 60 min. The results showed that the radioiodinated IBZM had high affinity, saturation and specificity to rat's and rabbit's central nerves system dopamine D2 receptors

  2. An enhanced CCRTM (E-CCRTM) damage imaging technique using a 2D areal scan for composite plates

    Science.gov (United States)

    He, Jiaze; Yuan, Fuh-Gwo

    2016-04-01

    A two-dimensional (2-D) non-contact areal scan system was developed to image and quantify impact damage in a composite plate using an enhanced zero-lag cross-correlation reverse-time migration (E-CCRTM) technique. The system comprises a single piezoelectric actuator mounted on the composite plate and a laser Doppler vibrometer (LDV) for scanning a region to capture the scattered wavefield in the vicinity of the PZT. The proposed damage imaging technique takes into account the amplitude, phase, geometric spreading, and all of the frequency content of the Lamb waves propagating in the plate; thus, the reflectivity coefficients of the delamination can be calculated and potentially related to damage severity. Comparisons are made in terms of damage imaging quality between 2-D areal scans and linear scans as well as between the proposed and existing imaging conditions. The experimental results show that the 2-D E-CCRTM performs robustly when imaging and quantifying impact damage in large-scale composites using a single PZT actuator with a nearby areal scan using LDV.

  3. 4D rotational x-ray imaging of wrist joint dynamic motion

    International Nuclear Information System (INIS)

    Carelsen, Bart; Bakker, Niels H.; Strackee, Simon D.; Boon, Sjirk N.; Maas, Mario; Sabczynski, Joerg; Grimbergen, Cornelis A.; Streekstra, Geert J.

    2005-01-01

    Current methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray modalities and sophisticated 2D to 3D matching for the complex wrist joint. We present a method for the acquisition of dynamic 3D images of a moving joint. In our method a 3D-rotational x-ray (3D-RX) system is used to image a cyclically moving joint. The cyclic motion is synchronized to the x-ray acquisition to yield multiple sets of projection images, which are reconstructed to a series of time resolved 3D images, i.e., four-dimensional rotational x ray (4D-RX). To investigate the obtained image quality parameters the full width at half maximum (FWHM) of the point spread function (PSF) via the edge spread function and the contrast to noise ratio between air and phantom were determined on reconstructions of a bullet and rod phantom, using 4D-RX as well as stationary 3D-RX images. The CNR in volume reconstructions based on 251 projection images in the static situation and on 41 and 34 projection images of a moving phantom were 6.9, 3.0, and 2.9, respectively. The average FWHM of the PSF of these same images was, respectively, 1.1, 1.7, and 2.2 mm orthogonal to the motion and parallel to direction of motion 0.6, 0.7, and 1.0 mm. The main deterioration of 4D-RX images compared to 3D-RX images is due to the low number of projection images used and not to the motion of the object. Using 41 projection images seems the best setting for the current system. Experiments on a postmortem wrist show the feasibility of the method for imaging 3D dynamic joint motion. We expect that 4D-RX will pave the way to improved assessment of joint disorders by detection of 3D dynamic motion patterns in joints

  4. MR imaging of cranial nerve lesions using six different high-resolution T1- and T2(*)-weighted 3D and 2D sequences

    Energy Technology Data Exchange (ETDEWEB)

    Seitz, J.; Held, P.; Strotzer, M.; Voelk, M.; Nitz, W.R.; Dorenbeck, U.; Feuerbach, S. [Univ. Hospital of Regensburg (Germany). Dept. of Diagnostic Radiology; Stamato, S. [Univ. of California, San Diego, CA (United States). Dept. of Radiology

    2002-07-01

    Purpose: To find a suitable high-resolution MR protocol for the visualization of lesions of all 12 cranial nerves. Material and Methods: Thirty-eight pathologically changed cranial nerves (17 patients) were studied with MR imaging at 1.5T using 3D T2*-weighted CISS, T1-weighted 3D MP-RAGE (without and with i.v. contrast medium), T2-weighted 3D TSE, T2-weighted 2D TSE and T1-weighted fat saturation 2D TSE sequences. Visibility of the 38 lesions of the 12 cranial nerves in each sequence was evaluated by consensus of two radiologists using an evaluation scale from 1 (excellently visible) to 4 (not visible). Results: The 3D CISS sequence provided the best resolution of the cranial nerves and their lesions when surrounded by CSF. In nerves which were not surrounded by CSF, the 2D T1-weighted contrast-enhanced fat suppression technique was the best sequence. Conclusions: A combination of 3D CISS, the 2D T1-weighted fat suppressed sequence and a 3D contrast-enhanced MP-RAGE proved to be the most useful sequence to visualize all lesions of the cranial nerves. For the determination of enhancement, an additional 3D MP-RAGE sequence without contrast medium is required. This sequence is also very sensitive for the detection of hemorrhage.

  5. MR imaging of cranial nerve lesions using six different high-resolution T1- and T2(*)-weighted 3D and 2D sequences

    International Nuclear Information System (INIS)

    Seitz, J.; Held, P.; Strotzer, M.; Voelk, M.; Nitz, W.R.; Dorenbeck, U.; Feuerbach, S.; Stamato, S.

    2002-01-01

    Purpose: To find a suitable high-resolution MR protocol for the visualization of lesions of all 12 cranial nerves. Material and Methods: Thirty-eight pathologically changed cranial nerves (17 patients) were studied with MR imaging at 1.5T using 3D T2*-weighted CISS, T1-weighted 3D MP-RAGE (without and with i.v. contrast medium), T2-weighted 3D TSE, T2-weighted 2D TSE and T1-weighted fat saturation 2D TSE sequences. Visibility of the 38 lesions of the 12 cranial nerves in each sequence was evaluated by consensus of two radiologists using an evaluation scale from 1 (excellently visible) to 4 (not visible). Results: The 3D CISS sequence provided the best resolution of the cranial nerves and their lesions when surrounded by CSF. In nerves which were not surrounded by CSF, the 2D T1-weighted contrast-enhanced fat suppression technique was the best sequence. Conclusions: A combination of 3D CISS, the 2D T1-weighted fat suppressed sequence and a 3D contrast-enhanced MP-RAGE proved to be the most useful sequence to visualize all lesions of the cranial nerves. For the determination of enhancement, an additional 3D MP-RAGE sequence without contrast medium is required. This sequence is also very sensitive for the detection of hemorrhage

  6. Diagnosis of spinal dural arteriovenous fistula using 3D T2-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kralik, Stephen F.; Murph, Daniel; Mehta, Peter; O' Neill, Darren P. [Indiana University School of Medicine, Department of Radiology and Imaging Sciences, Indianapolis, IN (United States)

    2017-10-15

    To evaluate spinal MRIs without and with 3D T2W imaging among patients without and with spinal dural arteriovenous fistula (SDAVF) confirmed by spinal digital subtraction angiography (DSA). A retrospective case-control study was performed among patients without and with SDAVF who had both spinal MRIs and gold standard spinal DSA. Two neuroradiologists independently reviewed spinal MRIs that were performed with either sagittal T2W turbo spin echo (2D group) or sagittal 3D T2W sampling perfection with application-optimized contrasts using different flip-angle evolutions (SPACE) (3D group) and documented the presence or absence of SDAVF. Using spinal DSA diagnosis as a gold standard, the sensitivity, specificity, and interobserver agreement for the 2D-group and 3D-group MRI diagnosis were calculated. The 2D group consisted of 21 patients and the 3D group consisted of 16 patients. For both radiologists, the 2D group demonstrated a sensitivity of 100% and specificity of 100%. Interobserver agreement in the 2D group was perfect (k = 1.0). For both radiologists, the 3D group demonstrated sensitivity of 100.0% and specificity of 92.3%. Interobserver agreement in the 3D group was perfect (k = 1.0). While flow voids were considered more conspicuous, spinal cord signal abnormality was considered less conspicuous with 3D T2W SPACE compared with conventional 2D STIR sequence. 3D T2W SPACE should be used in conjunction with 2D T2W sequences to more accurately detect abnormal cord signal and determine when perimedullary flow voids are pathologically abnormal for the radiologic diagnosis of SDAVF. (orig.)

  7. Simulation-Based Evaluation of Light Posts and Street Signs as 3-D Geolocation Targets in SAR Images

    Science.gov (United States)

    Auer, S.; Balss, U.

    2017-05-01

    The assignment of phase center positions (in 2D or 3D) derived from SAR data to physical object is challenging for many man-made structures such as buildings or bridges. In contrast, light poles and traffic signs are promising targets for tasks based on 3-D geolocation as they often show a prominent and spatially isolated appearance. For a detailed understanding of the nature of both targets, this paper presents results of a dedicated simulation case study, which is based on ray tracing methods (simulator RaySAR). For the first time, the appearance of the targets is analyzed in 2D (image plane) and 3D space (world coordinates of scene model) and reflecting surfaces are identified for related dominant image pixels. The case studies confirms the crucial impact of spatial resolution in the context of light poles and traffic signs and the appropriateness of light poles as target for 3-D geolocation in case of horizontal ground surfaces beneath.

  8. SIMULATION-BASED EVALUATION OF LIGHT POSTS AND STREET SIGNS AS 3-D GEOLOCATION TARGETS IN SAR IMAGES

    Directory of Open Access Journals (Sweden)

    S. Auer

    2017-05-01

    Full Text Available The assignment of phase center positions (in 2D or 3D derived from SAR data to physical object is challenging for many man-made structures such as buildings or bridges. In contrast, light poles and traffic signs are promising targets for tasks based on 3-D geolocation as they often show a prominent and spatially isolated appearance. For a detailed understanding of the nature of both targets, this paper presents results of a dedicated simulation case study, which is based on ray tracing methods (simulator RaySAR. For the first time, the appearance of the targets is analyzed in 2D (image plane and 3D space (world coordinates of scene model and reflecting surfaces are identified for related dominant image pixels. The case studies confirms the crucial impact of spatial resolution in the context of light poles and traffic signs and the appropriateness of light poles as target for 3-D geolocation in case of horizontal ground surfaces beneath.

  9. Simplifying the exploration of volumetric images: development of a 3D user interface for the radiologist's workplace.

    Science.gov (United States)

    Teistler, M; Breiman, R S; Lison, T; Bott, O J; Pretschner, D P; Aziz, A; Nowinski, W L

    2008-10-01

    Volumetric imaging (computed tomography and magnetic resonance imaging) provides increased diagnostic detail but is associated with the problem of navigation through large amounts of data. In an attempt to overcome this problem, a novel 3D navigation tool has been designed and developed that is based on an alternative input device. A 3D mouse allows for simultaneous definition of position and orientation of orthogonal or oblique multiplanar reformatted images or slabs, which are presented within a virtual 3D scene together with the volume-rendered data set and additionally as 2D images. Slabs are visualized with maximum intensity projection, average intensity projection, or standard volume rendering technique. A prototype has been implemented based on PC technology that has been tested by several radiologists. It has shown to be easily understandable and usable after a very short learning phase. Our solution may help to fully exploit the diagnostic potential of volumetric imaging by allowing for a more efficient reading process compared to currently deployed solutions based on conventional mouse and keyboard.

  10. EIT Imaging of admittivities with a D-bar method and spatial prior: experimental results for absolute and difference imaging.

    Science.gov (United States)

    Hamilton, S J

    2017-05-22

    Electrical impedance tomography (EIT) is an emerging imaging modality that uses harmless electrical measurements taken on electrodes at a body's surface to recover information about the internal electrical conductivity and or permittivity. The image reconstruction task of EIT is a highly nonlinear inverse problem that is sensitive to noise and modeling errors making the image reconstruction task challenging. D-bar methods solve the nonlinear problem directly, bypassing the need for detailed and time-intensive forward models, to provide absolute (static) as well as time-difference EIT images. Coupling the D-bar methodology with the inclusion of high confidence a priori data results in a noise-robust regularized image reconstruction method. In this work, the a priori D-bar method for complex admittivities is demonstrated effective on experimental tank data for absolute imaging for the first time. Additionally, the method is adjusted for, and tested on, time-difference imaging scenarios. The ability of the method to be used for conductivity, permittivity, absolute as well as time-difference imaging provides the user with great flexibility without a high computational cost.

  11. Automated curved planar reformation of 3D spine images

    International Nuclear Information System (INIS)

    Vrtovec, Tomaz; Likar, Bostjan; Pernus, Franjo

    2005-01-01

    Traditional techniques for visualizing anatomical structures are based on planar cross-sections from volume images, such as images obtained by computed tomography (CT) or magnetic resonance imaging (MRI). However, planar cross-sections taken in the coordinate system of the 3D image often do not provide sufficient or qualitative enough diagnostic information, because planar cross-sections cannot follow curved anatomical structures (e.g. arteries, colon, spine, etc). Therefore, not all of the important details can be shown simultaneously in any planar cross-section. To overcome this problem, reformatted images in the coordinate system of the inspected structure must be created. This operation is usually referred to as curved planar reformation (CPR). In this paper we propose an automated method for CPR of 3D spine images, which is based on the image transformation from the standard image-based to a novel spine-based coordinate system. The axes of the proposed spine-based coordinate system are determined on the curve that represents the vertebral column, and the rotation of the vertebrae around the spine curve, both of which are described by polynomial models. The optimal polynomial parameters are obtained in an image analysis based optimization framework. The proposed method was qualitatively and quantitatively evaluated on five CT spine images. The method performed well on both normal and pathological cases and was consistent with manually obtained ground truth data. The proposed spine-based CPR benefits from reduced structural complexity in favour of improved feature perception of the spine. The reformatted images are diagnostically valuable and enable easier navigation, manipulation and orientation in 3D space. Moreover, reformatted images may prove useful for segmentation and other image analysis tasks

  12. Combining different modalities for 3D imaging of biological objects

    International Nuclear Information System (INIS)

    Tsyganov, Eh.; Antich, P.; Kulkarni, P.; Mason, R.; Parkey, R.; Seliuonine, S.; Shay, J.; Soesbe, T.; Zhezher, V.; Zinchenko, A.

    2005-01-01

    A resolution enhanced NaI(Tl)-scintillator micro-SPECT device using pinhole collimator geometry has been built and tested with small animals. This device was constructed based on a depth-of-interaction measurement using a thick scintillator crystal and a position sensitive PMT to measure depth-dependent scintillator light profiles. Such a measurement eliminates the parallax error that degrades the high spatial resolution required for small animal imaging. This novel technique for 3D gamma-ray detection was incorporated into the micro-SPECT device and tested with a 57 Co source and 98m Tc-MDP injected in mice body. To further enhance the investigating power of the tomographic imaging different imaging modalities can be combined. In particular, as proposed and shown, the optical imaging permits a 3D reconstruction of the animal's skin surface thus improving visualization and making possible depth-dependent corrections, necessary for bioluminescence 3D reconstruction in biological objects. This structural information can provide even more detail if the x-ray tomography is used as presented in the paper

  13. Detail-enhanced multimodality medical image fusion based on gradient minimization smoothing filter and shearing filter.

    Science.gov (United States)

    Liu, Xingbin; Mei, Wenbo; Du, Huiqian

    2018-02-13

    In this paper, a detail-enhanced multimodality medical image fusion algorithm is proposed by using proposed multi-scale joint decomposition framework (MJDF) and shearing filter (SF). The MJDF constructed with gradient minimization smoothing filter (GMSF) and Gaussian low-pass filter (GLF) is used to decompose source images into low-pass layers, edge layers, and detail layers at multiple scales. In order to highlight the detail information in the fused image, the edge layer and the detail layer in each scale are weighted combined into a detail-enhanced layer. As directional filter is effective in capturing salient information, so SF is applied to the detail-enhanced layer to extract geometrical features and obtain directional coefficients. Visual saliency map-based fusion rule is designed for fusing low-pass layers, and the sum of standard deviation is used as activity level measurement for directional coefficients fusion. The final fusion result is obtained by synthesizing the fused low-pass layers and directional coefficients. Experimental results show that the proposed method with shift-invariance, directional selectivity, and detail-enhanced property is efficient in preserving and enhancing detail information of multimodality medical images. Graphical abstract The detailed implementation of the proposed medical image fusion algorithm.

  14. Forensic age estimation based on magnetic resonance imaging of third molars: converting 2D staging into 3D staging.

    Science.gov (United States)

    De Tobel, Jannick; Hillewig, Elke; Verstraete, Koenraad

    2017-03-01

    Established methods to stage development of third molars for forensic age estimation are based on the evaluation of radiographs, which show a 2D projection. It has not been investigated whether these methods require any adjustments in order to apply them to stage third molars on magnetic resonance imaging (MRI), which shows 3D information. To prospectively study root stage assessment of third molars in age estimation using 3 Tesla MRI and to compare this with panoramic radiographs, in order to provide considerations for converting 2D staging into 3D staging and to determine the decisive root. All third molars were evaluated in 52 healthy participants aged 14-26 years using MRI in three planes. Three staging methods were investigated by two observers. In sixteen of the participants, MRI findings were compared with findings on panoramic radiographs. Decisive roots were palatal in upper third molars and distal in lower third molars. Fifty-seven per cent of upper third molars were not assessable on the radiograph, while 96.9% were on MRI. Upper third molars were more difficult to evaluate on radiographs than on MRI (p third molars were equally assessable on both imaging techniques (93.8% MRI, 98.4% radiograph), with no difference in level of difficulty (p = .375). Inter- and intra-observer agreement for evaluation was higher in MRI than in radiographs. In both imaging techniques lower third molars showed greater inter- and intra-observer agreement compared to upper third molars. MR images in the sagittal plane proved to be essential for staging. In age estimation, 3T MRI of third molars could be valuable. Some considerations are, however, necessary to transfer known staging methods to this 3D technique.

  15. Initial clinical experiences with dopamine D{sub 2} receptor imaging by means of 2`-iodospiperone and single-photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yonekura, Yoshiharu [Fukui Medical Schoool, Matsuoka (Japan). Biomedical Imaging Research Center; Saji, Hideo; Iwasaki, Yasushi [and others

    1995-08-01

    Dopamine D{sub 2} receptor imaging was performed with {sup 123}I labeled 2`-iodospiperone (2`-ISP) and single-photon emission computed tomography (SPECT) in 9 patients: 4 with idiopathic Parkinson`s disease, 2 with parkinsonism, 1 with Wilson`s disease and 2 with pituitary tumor, and the results were compared with the data for 9 normal subjects. Following an intravenous injection of {sup 123}I-2`-ISP, early (within 30 min) and late (between 2 and 4 hr) SPECT images were obtained by means of a multi-detector SPECT scanner or a rotating gamma camera. In normal subjects, early SPECT images demonstrated uniform distribution of radioactivity in the cerebral gray matter and cerebellum reflecting regional cerebral blood flow, whereas late SPECT images showed high radioactivity only in the basal ganglia. All the patients with Parkinson`s disease also demonstrated symmetrical basal ganglia uptake in the late SPECT images, but it was diminished in parkinsonism and Wilson`s disease. One patient with a growth hormone-producing pituitary tumor had a positive uptake in the tumor. These preliminary clinical data demonstrated that 2`-ISP can be used for SPECT imaging of D{sub 2} dopamine receptors and may be of clinical value for the diagnosis and planning of the treatment of neurological diseases. (author).

  16. Estimation of water flow velocity in small plants using cold neutron imaging with D 2O tracer

    Science.gov (United States)

    Matsushima, U.; Herppich, W. B.; Kardjilov, N.; Graf, W.; Hilger, A.; Manke, I.

    2009-06-01

    Water flow imaging may help to better understand various problems related to water stress of plants. It may help to fully understand the water relations of plants. The objective of this research was to estimate the velocity of water flow in plant samples. Cut roses ( Rosa hybrida, var. 'Milva') were used as samples. Cold neutron radiography (CNR) was conducted at CONRAD, Helmholtz Center Berlin for Materials and Energy, Berlin, Germany. D 2O and H 2O were interchangeably injected into the water feeding system of the sample. After the uptake of D 2O, the neutron transmission increased due to the smaller attenuation coefficient of D 2O compared to H 2O. Replacement of D 2O in the rose peduncle was clearly observed. Three different optical flow algorithms, Block Matching, Horn-Schunck and Lucas-Kanade, were used to calculate the vector of D 2O tracer flow. The quality of sequential images providing sufficient spatial and temporal resolution allowed to estimate flow vector.

  17. MR imaging findings of diffuse axonal injury: comparison of T2-weighted gradient images and T1- and T2-weighted spin-echo images

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seo Young; Lee, Ghi Jai; Kim, Jeong Seok; Shim, Jae Chan; Kim, Ho Kyun [Inje Univ. College of Medicine, Seoul (Korea, Republic of)

    1998-10-01

    To compare T2-weighted images with spin-echo T1- and turbo spin-echo (TSE) T2-weighted images in patients with diffuse axonal injury(DAI). Using a 1.0T MR unit, SE T1-, TSE T2-, and and FLASH T2-weighted images were obtained from 69 patients with a history of head trauma. In 18MR images of 17 patients with imaging findings of DAI, T2-weighted images were retrospectively compared with SE T1- and TSE T2-weighted images. The interval between trauma and MR scan varied from 5 days to 24(mean, 11) months. Focusing on the number of lesions, and their location and signal intensity, as weel as associated findings, three images were simultaueously evaluated. In 18 MR images of 17 patients with MR imaging findings of DAI, 21 lesions were detected on T1-weighted images, 28 on TSE T2-weighted images, and 70 on T2-weighted images;the last of these revealed all lesions detected on the other two. Most lesions were hypointense on T1-weighted images(17/21), hyperintense on TSE T2-weighted (21/28), and hypointense on T2-weighted (63/70). Common locations for DAI were the frontal lobe (n=3D35) and corpus callosum (n=3D22). Associated brain injuries were cortical contusion (n=3D5), brainstem injury (n=3D3), deep gray matter injury (n=3D2), and subdural hematoma(n=3D1). In patients with DAI. T2-weighted images can detect more lesions and associated petechial hemorrhage than can TSE T2-weighted images. This modality is thus useful for the evaluation of patients with head trauma.=20.

  18. Rainbow Particle Imaging Velocimetry for Dense 3D Fluid Velocity Imaging

    KAUST Repository

    Xiong, Jinhui

    2017-04-11

    Despite significant recent progress, dense, time-resolved imaging of complex, non-stationary 3D flow velocities remains an elusive goal. In this work we tackle this problem by extending an established 2D method, Particle Imaging Velocimetry, to three dimensions by encoding depth into color. The encoding is achieved by illuminating the flow volume with a continuum of light planes (a “rainbow”), such that each depth corresponds to a specific wavelength of light. A diffractive component in the camera optics ensures that all planes are in focus simultaneously. For reconstruction, we derive an image formation model for recovering stationary 3D particle positions. 3D velocity estimation is achieved with a variant of 3D optical flow that accounts for both physical constraints as well as the rainbow image formation model. We evaluate our method with both simulations and an experimental prototype setup.

  19. A scintillating GEM detector for 2D dose imaging in hadron therapy

    NARCIS (Netherlands)

    Seravalli, E.

    2008-01-01

    The main aim of radiotherapy techniques is to deliver the dose to the target volume while sparing as much as possible the healthy tissue. Dose verifications prior the treatment of the patient are mandatory in order to guarantee high accuracy to the treatment. We have developed a 2D dose imaging

  20. SU-E-J-157: Improving the Quality of T2-Weighted 4D Magnetic Resonance Imaging for Clinical Evaluation

    International Nuclear Information System (INIS)

    Du, D; Mutic, S; Hu, Y; Caruthers, S; Glide-Hurst, C; Low, D

    2014-01-01

    Purpose: To develop an imaging technique that enables us to acquire T2- weighted 4D Magnetic Resonance Imaging (4DMRI) with sufficient spatial coverage, temporal resolution and spatial resolution for clinical evaluation. Methods: T2-weighed 4DMRI images were acquired from a healthy volunteer using a respiratory amplitude triggered T2-weighted Turbo Spin Echo sequence. 10 respiratory states were used to equally sample the respiratory range based on amplitude (0%, 20%i, 40%i, 60%i, 80%i, 100%, 80%e, 60%e, 40%e and 20%e). To avoid frequent scanning halts, a methodology was devised that split 10 respiratory states into two packages in an interleaved manner and packages were acquired separately. Sixty 3mm sagittal slices at 1.5mm in-plane spatial resolution were acquired to offer good spatial coverage and reasonable spatial resolution. The in-plane field of view was 375mm × 260mm with nominal scan time of 3 minutes 42 seconds. Acquired 2D images at the same respiratory state were combined to form the 3D image set corresponding to that respiratory state and reconstructed in the coronal view to evaluate whether all slices were at the same respiratory state. 3D image sets of 10 respiratory states represented a complete 4D MRI image set. Results: T2-weighted 4DMRI image were acquired in 10 minutes which was within clinical acceptable range. Qualitatively, the acquired MRI images had good image quality for delineation purposes. There were no abrupt position changes in reconstructed coronal images which confirmed that all sagittal slices were in the same respiratory state. Conclusion: We demonstrated it was feasible to acquire T2-weighted 4DMRI image set within a practical amount of time (10 minutes) that had good temporal resolution (10 respiratory states), spatial resolution (1.5mm × 1.5mm × 3.0mm) and spatial coverage (60 slices) for future clinical evaluation

  1. WE-AB-BRA-01: 3D-2D Image Registration for Target Localization in Spine Surgery: Comparison of Similarity Metrics Against Robustness to Content Mismatch

    International Nuclear Information System (INIS)

    De Silva, T; Ketcha, M; Siewerdsen, J H; Uneri, A; Reaungamornrat, S; Vogt, S; Kleinszig, G; Lo, S F; Wolinsky, J P; Gokaslan, Z L; Aygun, N

    2015-01-01

    Purpose: In image-guided spine surgery, mapping 3D preoperative images to 2D intraoperative images via 3D-2D registration can provide valuable assistance in target localization. However, the presence of surgical instrumentation, hardware implants, and soft-tissue resection/displacement causes mismatches in image content, confounding existing registration methods. Manual/semi-automatic methods to mask such extraneous content is time consuming, user-dependent, error prone, and disruptive to clinical workflow. We developed and evaluated 2 novel similarity metrics within a robust registration framework to overcome such challenges in target localization. Methods: An IRB-approved retrospective study in 19 spine surgery patients included 19 preoperative 3D CT images and 50 intraoperative mobile radiographs in cervical, thoracic, and lumbar spine regions. A neuroradiologist provided truth definition of vertebral positions in CT and radiography. 3D-2D registration was performed using the CMA-ES optimizer with 4 gradient-based image similarity metrics: (1) gradient information (GI); (2) gradient correlation (GC); (3) a novel variant referred to as gradient orientation (GO); and (4) a second variant referred to as truncated gradient correlation (TGC). Registration accuracy was evaluated in terms of the projection distance error (PDE) of the vertebral levels. Results: Conventional similarity metrics were susceptible to gross registration error and failure modes associated with the presence of surgical instrumentation: for GI, the median PDE and interquartile range was 33.0±43.6 mm; similarly for GC, PDE = 23.0±92.6 mm respectively. The robust metrics GO and TGC, on the other hand, demonstrated major improvement in PDE (7.6 ±9.4 mm and 8.1± 18.1 mm, respectively) and elimination of gross failure modes. Conclusion: The proposed GO and TGC similarity measures improve registration accuracy and robustness to gross failure in the presence of strong image content mismatch. Such

  2. WE-AB-BRA-01: 3D-2D Image Registration for Target Localization in Spine Surgery: Comparison of Similarity Metrics Against Robustness to Content Mismatch

    Energy Technology Data Exchange (ETDEWEB)

    De Silva, T; Ketcha, M; Siewerdsen, J H [Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD (United States); Uneri, A; Reaungamornrat, S [Department of Computer Science, Johns Hopkins University, Baltimore, MD (United States); Vogt, S; Kleinszig, G [Siemens Healthcare XP Division, Erlangen, DE (Germany); Lo, S F; Wolinsky, J P; Gokaslan, Z L [Department of Neurosurgery, The Johns Hopkins Hospital, Baltimore, MD (United States); Aygun, N [Department of Raiology and Radiological Sciences, The Johns Hopkins Hospital, Baltimore, MD (United States)

    2015-06-15

    Purpose: In image-guided spine surgery, mapping 3D preoperative images to 2D intraoperative images via 3D-2D registration can provide valuable assistance in target localization. However, the presence of surgical instrumentation, hardware implants, and soft-tissue resection/displacement causes mismatches in image content, confounding existing registration methods. Manual/semi-automatic methods to mask such extraneous content is time consuming, user-dependent, error prone, and disruptive to clinical workflow. We developed and evaluated 2 novel similarity metrics within a robust registration framework to overcome such challenges in target localization. Methods: An IRB-approved retrospective study in 19 spine surgery patients included 19 preoperative 3D CT images and 50 intraoperative mobile radiographs in cervical, thoracic, and lumbar spine regions. A neuroradiologist provided truth definition of vertebral positions in CT and radiography. 3D-2D registration was performed using the CMA-ES optimizer with 4 gradient-based image similarity metrics: (1) gradient information (GI); (2) gradient correlation (GC); (3) a novel variant referred to as gradient orientation (GO); and (4) a second variant referred to as truncated gradient correlation (TGC). Registration accuracy was evaluated in terms of the projection distance error (PDE) of the vertebral levels. Results: Conventional similarity metrics were susceptible to gross registration error and failure modes associated with the presence of surgical instrumentation: for GI, the median PDE and interquartile range was 33.0±43.6 mm; similarly for GC, PDE = 23.0±92.6 mm respectively. The robust metrics GO and TGC, on the other hand, demonstrated major improvement in PDE (7.6 ±9.4 mm and 8.1± 18.1 mm, respectively) and elimination of gross failure modes. Conclusion: The proposed GO and TGC similarity measures improve registration accuracy and robustness to gross failure in the presence of strong image content mismatch. Such

  3. Predicting Electron Population Characteristics in 2-D Using Multispectral Ground-Based Imaging

    Science.gov (United States)

    Grubbs, Guy; Michell, Robert; Samara, Marilia; Hampton, Donald; Jahn, Jorg-Micha

    2018-01-01

    Ground-based imaging and in situ sounding rocket data are compared to electron transport modeling for an active inverted-V type auroral event. The Ground-to-Rocket Electrodynamics-Electrons Correlative Experiment (GREECE) mission successfully launched from Poker Flat, Alaska, on 3 March 2014 at 11:09:50 UT and reached an apogee of approximately 335 km over the aurora. Multiple ground-based electron-multiplying charge-coupled device (EMCCD) imagers were positioned at Venetie, Alaska, and aimed toward magnetic zenith. The imagers observed the intensity of different auroral emission lines (427.8, 557.7, and 844.6 nm) at the magnetic foot point of the rocket payload. Emission line intensity data are correlated with electron characteristics measured by the GREECE onboard electron spectrometer. A modified version of the GLobal airglOW (GLOW) model is used to estimate precipitating electron characteristics based on optical emissions. GLOW predicted the electron population characteristics with 20% error given the observed spectral intensities within 10° of magnetic zenith. Predictions are within 30% of the actual values within 20° of magnetic zenith for inverted-V-type aurora. Therefore, it is argued that this technique can be used, at least in certain types of aurora, such as the inverted-V type presented here, to derive 2-D maps of electron characteristics. These can then be used to further derive 2-D maps of ionospheric parameters as a function of time, based solely on multispectral optical imaging data.

  4. 3D-LSI technology for image sensor

    International Nuclear Information System (INIS)

    Motoyoshi, Makoto; Koyanagi, Mitsumasa

    2009-01-01

    Recently, the development of three-dimensional large-scale integration (3D-LSI) technologies has accelerated and has advanced from the research level or the limited production level to the investigation level, which might lead to mass production. By separating 3D-LSI technology into elementary technologies such as (1) through silicon via (TSV) formation, (2) bump formation, (3) wafer thinning, (4) chip/wafer alignment, and (5) chip/wafer stacking and reconstructing the entire process and structure, many methods to realize 3D-LSI devices can be developed. However, by considering a specific application, the supply chain of base wafers, and the purpose of 3D integration, a few suitable combinations can be identified. In this paper, we focus on the application of 3D-LSI technologies to image sensors. We describe the process and structure of the chip size package (CSP), developed on the basis of current and advanced 3D-LSI technologies, to be used in CMOS image sensors. Using the current LSI technologies, CSPs for 1.3 M, 2 M, and 5 M pixel CMOS image sensors were successfully fabricated without any performance degradation. 3D-LSI devices can be potentially employed in high-performance focal-plane-array image sensors. We propose a high-speed image sensor with an optical fill factor of 100% to be developed using next-generation 3D-LSI technology and fabricated using micro(μ)-bumps and micro(μ)-TSVs.

  5. A detailed study of FDIRC prototype with waveform digitizing electronics in cosmic ray telescope using 3D tracks

    Science.gov (United States)

    Nishimura, K.; Dey, B.; Aston, D.; Leith, D. W. G. S.; Ratcliff, B.; Roberts, D.; Ruckman, L.; Shtol, D.; Varner, G. S.; Va'vra, J.

    2013-02-01

    We present a detailed study of a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC) with waveform digitizing electronics. In this study, the FDIRC prototype has been instrumented with seven Hamamatsu H-8500 MaPMTs. Waveforms from 384 pixels are digitized with waveform sampling electronics based on the BLAB2 ASIC, operating at a sampling speed of ∼2.5 GSa/s. The FDIRC prototype was tested in a large cosmic ray telescope (CRT) providing 3D muon tracks with ∼1.5 mrad angular resolution and muon energy of Emuon> 1.6 GeV. In this study we provide a detailed analysis of the tails in the Cherenkov angle distribution as a function of various variables, compare experimental results with simulation, and identify the major contributions to the tails. We demonstrate that to see the full impact of these tails on the Cherenkov angle resolution, it is crucial to use 3D tracks, and have a full understanding of the role of reconstruction ambiguities. These issues could not be fully explored in previous FDIRC studies where the beam was perpendicular to the quartz radiator bars. This work is relevant for the final FDIRC prototype of the PID detector at SuperB, which will be tested this year in the CRT setup.

  6. A Detailed Study of FDIRC Prototype with Waveform Digitizing Electronics in Cosmic Ray Telescope Using 3D Tracks

    International Nuclear Information System (INIS)

    Nishimura, K.; Dey, B.; Aston, D.; Leith, D.W.G.S.; Ratcliff, B.; Roberts, D.; Ruckman, L.; Shtol, D.; Varner, G.S.; Va'vra, J.

    2012-01-01

    We present a detailed study of a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC) with waveform digitizing electronics. In this test study, the FDIRC prototype has been instrumented with seven Hamamatsu H-8500 MaPMTs. Waveforms from ∼450 pixels are digitized with waveform sampling electronics based on the BLAB2 ASIC, operating at a sampling speed of ∼2.5 GSa/s. The FDIRC prototype was tested in a large cosmic ray telescope (CRT) providing 3D muon tracks with ∼1.5 mrad angular resolution and muon energy of E muon > 1.6 GeV. In this study we provide a detailed analysis of the tails in the Cherenkov angle distribution as a function of various variables, compare experimental results with simulation, and identify the major contributions to the tails. We demonstrate that to see the full impact of these tails on the Cherenkov angle resolution, it is crucial to use 3D tracks, and have a full understanding of the role of ambiguities. These issues could not be fully explored in previous FDIRC studies where the beam was perpendicular to the quartz radiator bars. This work is relevant for the final FDIRC prototype of the PID detector at SuperB, which will be tested this year in the CRT setup.

  7. Imaging the internal structure of fluid upflow zones with detailed digital Parasound echosounder surveys

    Science.gov (United States)

    Spiess, V.; Zuehlsdorff, L.; von Lom-Keil, H.; Schwenk, T.

    2001-12-01

    Sites of venting fluids both with continuous and episodic supply often reveal complex surface and internal structures, which are difficult to image and cause problems to transfer results from local sampling towards a structural reconstruction and a quantification of (average) flux rates. Detailed acoustic and seismic surveys would be required to retrieve this information, but also an appropriate environment, where fluid migration can be properly imaged from contrasts to unaffected areas. Hemipelagic sediments are most suitable, since typically reflectors are coherent and of low lateral amplitude variation and structures are continuous over distances much longer than the scale of fluid migration features. During RV Meteor Cruise M473 and RV Sonne Cruise SO 149 detailed studies were carried out in the vicinity of potential fluid upflow zones in the Lower Congo Basin at 5oS in 3000 m water depth and at the Northern Cascadia Margin in 1000 m water depth. Unexpected sampling of massive gas hydrates from the sea floor as well as of carbonate concretions, shell fragments and different liveforms indicated active fluid venting in a typically hemipelagic realm. The acoustic signature of such zones includes columnar blanking, pockmark depressions at the sea floor, association with small offset faults (ParaDigMA System for further processing and display, to image the spatial structure of the upflow zones. Due to the high data density amplitudes and other acoustic properties could be investigated in a 3D volume and time slices as well as reflector surfaces were analyzed. Pronounced lateral variations of reflection amplitudes within a complex pattern indicate potential pathways for fluid/gas migration and occurrences of near-surface gas hydrate deposits, which may be used to trace detailed surface evidence from side scan sonar imaging down to depth and support dedicated sampling.

  8. 3D-2D image registration for target localization in spine surgery: investigation of similarity metrics providing robustness to content mismatch

    Science.gov (United States)

    De Silva, T.; Uneri, A.; Ketcha, M. D.; Reaungamornrat, S.; Kleinszig, G.; Vogt, S.; Aygun, N.; Lo, S.-F.; Wolinsky, J.-P.; Siewerdsen, J. H.

    2016-04-01

    In image-guided spine surgery, robust three-dimensional to two-dimensional (3D-2D) registration of preoperative computed tomography (CT) and intraoperative radiographs can be challenged by the image content mismatch associated with the presence of surgical instrumentation and implants as well as soft-tissue resection or deformation. This work investigates image similarity metrics in 3D-2D registration offering improved robustness against mismatch, thereby improving performance and reducing or eliminating the need for manual masking. The performance of four gradient-based image similarity metrics (gradient information (GI), gradient correlation (GC), gradient information with linear scaling (GS), and gradient orientation (GO)) with a multi-start optimization strategy was evaluated in an institutional review board-approved retrospective clinical study using 51 preoperative CT images and 115 intraoperative mobile radiographs. Registrations were tested with and without polygonal masks as a function of the number of multistarts employed during optimization. Registration accuracy was evaluated in terms of the projection distance error (PDE) and assessment of failure modes (PDE  >  30 mm) that could impede reliable vertebral level localization. With manual polygonal masking and 200 multistarts, the GC and GO metrics exhibited robust performance with 0% gross failures and median PDE  interquartile range (IQR)) and a median runtime of 84 s (plus upwards of 1-2 min for manual masking). Excluding manual polygonal masks and decreasing the number of multistarts to 50 caused the GC-based registration to fail at a rate of  >14% however, GO maintained robustness with a 0% gross failure rate. Overall, the GI, GC, and GS metrics were susceptible to registration errors associated with content mismatch, but GO provided robust registration (median PDE  =  5.5 mm, 2.6 mm IQR) without manual masking and with an improved runtime (29.3 s). The GO metric

  9. "3D fusion" echocardiography improves 3D left ventricular assessment: comparison with 2D contrast echocardiography.

    Science.gov (United States)

    Augustine, Daniel; Yaqub, Mohammad; Szmigielski, Cezary; Lima, Eduardo; Petersen, Steffen E; Becher, Harald; Noble, J Alison; Leeson, Paul

    2015-02-01

    Three-dimensional fusion echocardiography (3DFE) is a novel postprocessing approach that utilizes imaging data acquired from multiple 3D acquisitions. We assessed image quality, endocardial border definition, and cardiac wall motion in patients using 3DFE compared to standard 3D images (3D) and results obtained with contrast echocardiography (2DC). Twenty-four patients (mean age 66.9 ± 13 years, 17 males, 7 females) undergoing 2DC had three, noncontrast, 3D apical volumes acquired at rest. Images were fused using an automated image fusion approach. Quality of the 3DFE was compared to both 3D and 2DC based on contrast-to-noise ratio (CNR) and endocardial border definition. We then compared clinical wall-motion score index (WMSI) calculated from 3DFE and 3D to those obtained from 2DC images. Fused 3D volumes had significantly improved CNR (8.92 ± 1.35 vs. 6.59 ± 1.19, P echocardiography (1.06 ± 0.09 vs. 1.07 ± 0.15, P = 0.69), whereas unfused images produced significantly more variable results (1.19 ± 0.30). This was confirmed by a better intraclass correlation coefficient (ICC 0.72; 95% CI 0.32-0.88) relative to comparisons with unfused images (ICC 0.56; 95% CI 0.02-0.81). 3DFE significantly improves left ventricular image quality compared to unfused 3D in a patient population and allows noncontrast assessment of wall motion that approaches that achieved with 2D contrast echocardiography. © 2014, Wiley Periodicals, Inc.

  10. New Algorithm to Enable Construction and Display of 3D Structures from Scanning Probe Microscopy Images Acquired Layer-by-Layer.

    Science.gov (United States)

    Deng, William Nanqiao; Wang, Shuo; Ventrici de Souza, Joao Francisco; Kuhl, Tonya L; Liu, Gang-Yu

    2018-06-11

    Scanning probe microscopy (SPM) such as atomic force microscopy (AFM) is widely known for high-resolution imaging of surface structures and nanolithography in two dimension (2D), which provides important physical insights in surface science and material science. This work reports a new algorithm to enable construction and display of layer-by-layer 3D structures from SPM images. The algorithm enables alignment of SPM images acquired during layer-by-layer deposition, removal of redundant features, and faithfully constructs the deposited 3D structures. The display uses a "see-through" strategy to enable the structure of each layer to be visible. The results demonstrate high spatial accuracy as well as algorithm versatility; users can set parameters for reconstruction and display as per image quality and research needs. To the best of our knowledge, this method represents the first report to enable SPM technology for 3D imaging construction and display. The detailed algorithm is provided to facilitate usage of the same approach in any SPM software. These new capabilities support wide applications of SPM that require 3D image reconstruction and display, such as 3D nanoprinting, and 3D additive and subtractive manufacturing and imaging.

  11. Radioiodination of central nerves system dopamine D2 receptor imaging agent. IBZM preparation and preclinical study

    Energy Technology Data Exchange (ETDEWEB)

    Yansong, Lin; Xiangtong, Lin; Mingyang, Hu; Shangren, Pan; Bocheng, Wang [Huashan Hospital of Shanghai Medical Univ., Shanghai (China)

    1996-11-01

    To study preparation of central nerves system dopamine D2 imaging agent {sup 131}I-IBZM and its preclinical investigation, peracetic acid was used as the oxidant for preparing radioiodinated {sup 125}I-IBZM and {sup 131}I-IBZM, D2 binding properties of IBZM were examined by in vitro binding saturation analysis, rat whole body and regional brain biodistribution, rat brain autoradiography and rabbit SPECT static imaging, etc. The results are: 1. The radiolabelling yields of {sup 125}I-IBZM and {sup 131}I-IBZM were 84.18% +- 3.06% and 78.50% +- 3.47%. The radiochemical purity were over 95% after being isolated by HPLC; and were over 90% after being isolated by organic extraction. 2. Scatchard plot of D2 receptor saturation binding analysis showed: K{sub d} = 0.53 +- 0.06 nmol/L, B{sub max} = 466.45 +- 45.88 fmol/mg protein. 3. The rat brain autoradiography and analysis showed that there was high {sup 125}I-IBZM uptake in striatal area 2 hr after injection, the striatal/cerebellum ratio was 6.22 +- 0.48; the high {sup 125}-IBZM uptake can be blocked by haloperidol--a special dopamine D2 receptor antagonist. 4. {sup 131}I-IBZM rat biodistribution and rabbit SPECT planar imaging showed good initial brain uptake and retention, the initial uptake of rat brain was 1.893 +- 0.147% ID/g at 2 min and 1.044 +- 0.135% ID/g at 60 min. The results showed that the radioiodinated IBZM had high affinity, saturation and specificity to rat`s and rabbit`s central nerves system dopamine D2 receptors.

  12. Novel three-dimensional imaging volumetry in autosomal dominant polycystic kidney disease: comparison with 2D volumetry.

    Science.gov (United States)

    Shin, Dongsuk; Lee, Kyu-Beck; Hyun, Young Youl; Lee, Young Rae; Hwang, Young-Hwan; Park, Hayne Cho; Ahn, Curie

    2014-08-01

    Autosomal dominant polycystic kidney disease (ADPKD) volumetry is an important marker for evaluating the progression of disease. Three-dimensional (3D) volumetry is generally more timesaving than 2D volumetry, but its reliability and accuracy are uncertain. Small and large phantoms simulating polycystic kidneys and 20 patients with ADPKD underwent magnetic resonance imaging (MRI) volumetry. We evaluated the total kidney volume (TKV) and total cyst volume (TCV) using a novel 3D volumetry program (XelisTM) and compared 3D volumetry data with the conventional 2D method (the reference volume values). After upload and threshold setting, the other organs surrounding the kidney were removed by picking and sculpting. The novel method involves drawing of the kidney or cyst and automatic measurement of kidney volume and cyst volume in 3D images. The 3D volume estimation of the small and large phantoms differed from the actual values by 6.9% and -8.2%, respectively, for TKV and by 2.1% and 1.4% for TCV. In ADPKD patients, the intra-reader reliability of 3D volumetry was 30 ± 180 mL (1.3 ± 10.3%) and 25 ± 113 mL (1.2 ± 9.4%), respectively, for TKV and TCV. Correlation between 3D volumetry and 2D volumetry of TKV and TCV resulted in a high correlation coefficient and a regression slope approaching 1.00 (r = 0.97 - 0.98). The mean of the volume percentage differences for 3D vs. 2D for TKV : TCV were -6.0 ± 8.9% : 2.0 ± 11.8% in large ADPKD and -16.1 ± 10.4% : 13.2 ± 21.9% in small ADPKD. Our study showed that 3D volumetry has reliability and accuracy compared with 2D volumetry in ADPKD. 3D volumetry is more accurate for TCV and large ADPKD.

  13. Assessment of Myocardial Fibrosis in Mice Using a T2*-Weighted 3D Radial Magnetic Resonance Imaging Sequence.

    Directory of Open Access Journals (Sweden)

    Bastiaan J van Nierop

    Full Text Available Myocardial fibrosis is a common hallmark of many diseases of the heart. Late gadolinium enhanced MRI is a powerful tool to image replacement fibrosis after myocardial infarction (MI. Interstitial fibrosis can be assessed indirectly from an extracellular volume fraction measurement using contrast-enhanced T1 mapping. Detection of short T2* species resulting from fibrotic tissue may provide an attractive non-contrast-enhanced alternative to directly visualize the presence of both replacement and interstitial fibrosis.To goal of this paper was to explore the use of a T2*-weighted radial sequence for the visualization of fibrosis in mouse heart.C57BL/6 mice were studied with MI (n = 20, replacement fibrosis, transverse aortic constriction (TAC (n = 18, diffuse fibrosis, and as control (n = 10. 3D center-out radial T2*-weighted images with varying TE were acquired in vivo and ex vivo (TE = 21 μs-4 ms. Ex vivo T2*-weighted signal decay with TE was analyzed using a 3-component model. Subtraction of short- and long-TE images was used to highlight fibrotic tissue with short T2*. The presence of fibrosis was validated using histology and correlated to MRI findings.Detailed ex vivo T2*-weighted signal analysis revealed a fast (T2*fast, slow (T2*slow and lipid (T2*lipid pool. T2*fast remained essentially constant. Infarct T2*slow decreased significantly, while a moderate decrease was observed in remote tissue in post-MI hearts and in TAC hearts. T2*slow correlated with the presence of diffuse fibrosis in TAC hearts (r = 0.82, P = 0.01. Ex vivo and in vivo subtraction images depicted a positive contrast in the infarct co-localizing with the scar. Infarct volumes from histology and subtraction images linearly correlated (r = 0.94, P<0.001. Region-of-interest analysis in the in vivo post-MI and TAC hearts revealed significant T2* shortening due to fibrosis, in agreement with the ex vivo results. However, in vivo contrast on subtraction images was rather poor

  14. Edge fluctuation measurements by phase contrast imaging on DIII-D

    International Nuclear Information System (INIS)

    Coda, S.; Porkolab, M.

    1994-05-01

    A novel CO 2 laser phase contrast imaging diagnostic has been developed for the DIII-D tokamak, where it is being employed to investigate density fluctuations at the outer edge of the plasma. This system generates 16-point, 1-D images of a 7.6 cm wide region in the radial direction, and is characterized by long wavelength (7.6 cm) and high frequency (100 MHz) capability, as well as excellent sensitivity (rvec n approx-gt 10 9 cm -3 ). The effects of vertical line integration have been studied in detail, both analytically and numerically with actual flux surface geometries generated by the EFITD magnetic equilibrium code. It is shown that in the present configuration the measurement is mostly sensitive to radial wave vectors. Experimental results on fluctuation suppression at the L- to H-mode transition and on the L-mode wave number spectrum are discussed briefly. Finally, future plans for extending the measurement to the core of the plasma and for investigating externally launched fast waves are presented

  15. Multivariate cluster analysis of dynamic iodine-123 iodobenzamide SPET dopamine D{sub 2}receptor images in schizophrenia

    Energy Technology Data Exchange (ETDEWEB)

    Acton, P.D. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom); Pilowsky, L.S. [Institute of Psychiatry, London (United Kingdom); Costa, D.C. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom); Ell, P.J. [Inst. of Nuclear Medicine, Univ. Coll. London Medical School, London (United Kingdom)

    1997-02-01

    This paper describes the application of a multivariate statistical technique to investigate striatal dopamine D{sub 2}receptor concentrations measured by iodine-123 iodobenzamide ({sup 123}I-IBZM) single-photon emission tomography (SPET). This technique enables the automatic segmentation of dynamic nuclear medicine images based on the underlying time-activity curves present in the data. Once the time-activity curves have been extracted, each pixel can be mapped back on to the underlying distribution, considerably reducing image noise. Cluster analysis has been verified using computer simulations and phantom studies. The technique has been applied to SPET images of dopamine D {sub 2}receptors in a total of 20 healthy and 20 schizophrenic volunteers (22 male, 18 female), using the ligand {sup 123}I-IBZM. Following automatic image segmentation, the concentration of striatal dopamine D {sub 2}receptors shows a significant left-sided asymmetry in male schizophrenics compared with male controls. The mean left-minus-right laterality index for controls is -1.52 (95% CI -3.72-0.66) and for patients 4.04 (95% CI 1.07-7.01). Analysis of variance shows a case-by-sex-by-side interaction, with F=10.01, P=0.005. We can now demonstrate that the previously observed male sex-specific D {sub 2}receptor asymmetry in schizophrenia, which had failed to attain statistical significance, is valid. Cluster analysis of dynamic nuclear medicine studies provides a powerful tool for automatic segmentation and noise reduction of the images, removing much of the subjectivity inherent in region-of-interest analysis. The observed striatal D {sub 2}asymmetry could reflect long hypothesized disruptions in dopamine-rich cortico-striatal-limbic circuits in schizophrenic males. (orig.). With 4 figs., 2 tabs.

  16. SU-E-T-431: Feasiblity of Using CT Scout Images for 2D LDR Brachytherpay Planning

    Energy Technology Data Exchange (ETDEWEB)

    Ha, J; Weaver, R [LAC+USC Medical Center, Los Angeles, CA, M. Mariscal (United States)

    2015-06-15

    Purpose: i) To show the feasibility of using CT scout images for 2D low-dose rate brachytherapy planning with BrachyVision (version 10.4); ii) to show their advantages and disadvantages over DRRs. Methods: A phantom was constructed to house a Fletcher-Suite applicator. The phantom is made of Styrofoam with metal BBs positioned at well-defined separations. These markers are used to assess the image distortion in the scout images. Unlike DRRs, scout images are distorted only in the direction normal to the couch direction; therefore, they needed to be scaled unidirectionally prior to importing into BrachyVision. In addition to confirming the scaling is performed correctly by measuring distances between well-positioned BB, we also compare a LDR plan using scout images to a 3D CT-based plan. Results: There is no distortion of the image along the couch direction due to the collimation of the CT scanner. The distortion in the transverse plane can be corrected by multiplying by the ratio of distances between source-to-isocenter and source-to-detector. The results show the distance separations between BBs as measured in scout images and by a caliber are within a few millimeters. Dosimetrically, the difference between the dose rates to points A and B based on scout images and on 3D CT are less than a few percents. The accuracy can be improved by correcting for the distortion on the transverse plane. Conclusion: It is possible to use CT scout images for 2D planning in BrachyVision. This is an advantage because scout images have no metal artifacts often present in CT images or DRRs. Another advantage is the lack of distortion in the couch direction. One major disadvantage is that the image distortion due to beam divergence can be large. This is due to the inherent short distance between source-to-isocenter and source-to-detector on a CT scanner.

  17. Exact monitoring of aortic diameters in Marfan patients without gadolinium contrast: intraindividual comparison of 2D SSFP imaging with 3D CE-MRA and echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Veldhoen, Simon [University Medical Center Wuerzburg, Department of Diagnostic and Interventional Radiology, Bavaria (Germany); University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Behzadi, Cyrus; Derlin, Thorsten; Henes, Frank Oliver; Adam, Gerhard; Bannas, Peter [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Rybczinsky, Meike; Kodolitsch, Yskert von; Sheikhzadeh, Sara [University Medical Center Hamburg-Eppendorf, Department of General and Interventional Cardiology, Hamburg (Germany); Bley, Thorsten Alexander [University Medical Center Wuerzburg, Department of Diagnostic and Interventional Radiology, Bavaria (Germany)

    2014-10-15

    To assess whether ECG-gated non-contrast 2D steady-state free precession (SSFP) imaging allows for exact monitoring of aortic diameters in Marfan syndrome (MFS) patients using non-ECG-gated contrast-enhanced 3D magnetic resonance angiography (CE-MRA) and echocardiography for intraindividual comparison. Non-ECG-gated CE-MRA and ECG-gated non-contrast SSFP at 1.5 T were prospectively performed in 50 patients. Two readers measured aortic diameters on para-sagittal images identically aligned with the aortic arch at the sinuses of Valsalva, sinotubular junction, ascending/descending aorta and aortic arch. Image quality was assessed on a three-point scale. Aortic root diameters acquired by echocardiography were used as reference. Intra- and interobserver variances were smaller for SSFP at the sinuses of Valsalva (p = 0.002; p = 0.002) and sinotubular junction (p = 0.014; p = 0.043). Image quality was better in SSFP than in CE-MRA at the sinuses of Valsalva (p < 0.0001), sinotubular junction (p < 0.0001) and ascending aorta (p = 0.02). CE-MRA yielded higher diameters than SSFP at the sinuses of Valsalva (mean bias, 2.5 mm; p < 0.0001), and comparison with echocardiography confirmed a higher bias for CE-MRA (7.2 ± 3.4 mm vs. SSFP, 4.7 ± 2.6 mm). ECG-gated non-contrast 2D SSFP imaging provides superior image quality with higher validity compared to non-ECG-gated contrast-enhanced 3D imaging. Since CE-MRA requires contrast agents with potential adverse effects, non-contrast SSFP imaging is an appropriate alternative for exact and riskless aortic monitoring of MFS patients. (orig.)

  18. Exact monitoring of aortic diameters in Marfan patients without gadolinium contrast: intraindividual comparison of 2D SSFP imaging with 3D CE-MRA and echocardiography

    International Nuclear Information System (INIS)

    Veldhoen, Simon; Behzadi, Cyrus; Derlin, Thorsten; Henes, Frank Oliver; Adam, Gerhard; Bannas, Peter; Rybczinsky, Meike; Kodolitsch, Yskert von; Sheikhzadeh, Sara; Bley, Thorsten Alexander

    2015-01-01

    To assess whether ECG-gated non-contrast 2D steady-state free precession (SSFP) imaging allows for exact monitoring of aortic diameters in Marfan syndrome (MFS) patients using non-ECG-gated contrast-enhanced 3D magnetic resonance angiography (CE-MRA) and echocardiography for intraindividual comparison. Non-ECG-gated CE-MRA and ECG-gated non-contrast SSFP at 1.5 T were prospectively performed in 50 patients. Two readers measured aortic diameters on para-sagittal images identically aligned with the aortic arch at the sinuses of Valsalva, sinotubular junction, ascending/descending aorta and aortic arch. Image quality was assessed on a three-point scale. Aortic root diameters acquired by echocardiography were used as reference. Intra- and interobserver variances were smaller for SSFP at the sinuses of Valsalva (p = 0.002; p = 0.002) and sinotubular junction (p = 0.014; p = 0.043). Image quality was better in SSFP than in CE-MRA at the sinuses of Valsalva (p < 0.0001), sinotubular junction (p < 0.0001) and ascending aorta (p = 0.02). CE-MRA yielded higher diameters than SSFP at the sinuses of Valsalva (mean bias, 2.5 mm; p < 0.0001), and comparison with echocardiography confirmed a higher bias for CE-MRA (7.2 ± 3.4 mm vs. SSFP, 4.7 ± 2.6 mm). ECG-gated non-contrast 2D SSFP imaging provides superior image quality with higher validity compared to non-ECG-gated contrast-enhanced 3D imaging. Since CE-MRA requires contrast agents with potential adverse effects, non-contrast SSFP imaging is an appropriate alternative for exact and riskless aortic monitoring of MFS patients. (orig.)

  19. Self-calibration of cone-beam CT geometry using 3D-2D image registration

    Science.gov (United States)

    Ouadah, S.; Stayman, J. W.; Gang, G. J.; Ehtiati, T.; Siewerdsen, J. H.

    2016-04-01

    Robotic C-arms are capable of complex orbits that can increase field of view, reduce artifacts, improve image quality, and/or reduce dose; however, it can be challenging to obtain accurate, reproducible geometric calibration required for image reconstruction for such complex orbits. This work presents a method for geometric calibration for an arbitrary source-detector orbit by registering 2D projection data to a previously acquired 3D image. It also yields a method by which calibration of simple circular orbits can be improved. The registration uses a normalized gradient information similarity metric and the covariance matrix adaptation-evolution strategy optimizer for robustness against local minima and changes in image content. The resulting transformation provides a ‘self-calibration’ of system geometry. The algorithm was tested in phantom studies using both a cone-beam CT (CBCT) test-bench and a robotic C-arm (Artis Zeego, Siemens Healthcare) for circular and non-circular orbits. Self-calibration performance was evaluated in terms of the full-width at half-maximum (FWHM) of the point spread function in CBCT reconstructions, the reprojection error (RPE) of steel ball bearings placed on each phantom, and the overall quality and presence of artifacts in CBCT images. In all cases, self-calibration improved the FWHM—e.g. on the CBCT bench, FWHM  =  0.86 mm for conventional calibration compared to 0.65 mm for self-calibration (p  robotic C-arm, RPE  =  0.73 mm for conventional calibration compared to 0.55 mm for self-calibration (p  <  0.001). Visible improvement was evident in CBCT reconstructions using self-calibration, particularly about high-contrast, high-frequency objects (e.g. temporal bone air cells and a surgical needle). The results indicate that self-calibration can improve even upon systems with presumably accurate geometric calibration and is applicable to situations where conventional calibration is not feasible

  20. 2D interpretation of vertical electrical soundings: application to the Sarantaporon basin (Thessaly, Greece)

    International Nuclear Information System (INIS)

    Atzemoglou, A; Tsourlos, P

    2012-01-01

    A large-scale vertical electrical sounding (VES) survey was applied at the basin of Sarantaporon, Elassona in order to study the tectonic and hydrogeological setting of the area. A large number of VES was obtained on a near-regular grid and data were initially processed with 1D inversion algorithm. Since some of the dense measured soundings were collinear, it was possible to combine 1D sounding data and produce 2D data sets which were interpreted using a fully 2D inversion algorithm. 2D geoelectrical models were in very good agreement with the existing drilling information of the area. 2D interpretation results were combined to produce pseudo-3D geoelectrical images of the subsurface. Resulting geoelectrical interpretations are in very good agreement with the existing geological information and reveal a relatively detailed picture of the basin's lithology. Further, the results allowed us to obtain new, and verify existing, structural information regarding the studied area. Overall, it is concluded that 2D interpretation of 1D VES measurements can produce improved subsurface geophysical images and presents a potential useful tool for larger scale geological investigations especially in the case of reprocessing existing VES data sets

  1. 3D surface reconstruction using optical flow for medical imaging

    International Nuclear Information System (INIS)

    Weng, Nan; Yang, Yee-Hong; Pierson, R.

    1996-01-01

    The recovery of a 3D model from a sequence of 2D images is very useful in medical image analysis. Image sequences obtained from the relative motion between the object and the camera or the scanner contain more 3D information than a single image. Methods to visualize the computed tomograms can be divided into two approaches: the surface rendering approach and the volume rendering approach. A new surface rendering method using optical flow is proposed. Optical flow is the apparent motion in the image plane produced by the projection of the real 3D motion onto 2D image. In this paper, the object remains stationary while the scanner undergoes translational motion. The 3D motion of an object can be recovered from the optical flow field using additional constraints. By extracting the surface information from 3D motion, it is possible to get an accurate 3D model of the object. Both synthetic and real image sequences have been used to illustrate the feasibility of the proposed method. The experimental results suggest that the proposed method is suitable for the reconstruction of 3D models from ultrasound medical images as well as other computed tomograms

  2. Software for 3D diagnostic image reconstruction and analysis

    International Nuclear Information System (INIS)

    Taton, G.; Rokita, E.; Sierzega, M.; Klek, S.; Kulig, J.; Urbanik, A.

    2005-01-01

    Recent advances in computer technologies have opened new frontiers in medical diagnostics. Interesting possibilities are the use of three-dimensional (3D) imaging and the combination of images from different modalities. Software prepared in our laboratories devoted to 3D image reconstruction and analysis from computed tomography and ultrasonography is presented. In developing our software it was assumed that it should be applicable in standard medical practice, i.e. it should work effectively with a PC. An additional feature is the possibility of combining 3D images from different modalities. The reconstruction and data processing can be conducted using a standard PC, so low investment costs result in the introduction of advanced and useful diagnostic possibilities. The program was tested on a PC using DICOM data from computed tomography and TIFF files obtained from a 3D ultrasound system. The results of the anthropomorphic phantom and patient data were taken into consideration. A new approach was used to achieve spatial correlation of two independently obtained 3D images. The method relies on the use of four pairs of markers within the regions under consideration. The user selects the markers manually and the computer calculates the transformations necessary for coupling the images. The main software feature is the possibility of 3D image reconstruction from a series of two-dimensional (2D) images. The reconstructed 3D image can be: (1) viewed with the most popular methods of 3D image viewing, (2) filtered and processed to improve image quality, (3) analyzed quantitatively (geometrical measurements), and (4) coupled with another, independently acquired 3D image. The reconstructed and processed 3D image can be stored at every stage of image processing. The overall software performance was good considering the relatively low costs of the hardware used and the huge data sets processed. The program can be freely used and tested (source code and program available at

  3. Rainbow particle imaging velocimetry for dense 3D fluid velocity imaging

    KAUST Repository

    Xiong, Jinhui

    2017-07-21

    Despite significant recent progress, dense, time-resolved imaging of complex, non-stationary 3D flow velocities remains an elusive goal. In this work we tackle this problem by extending an established 2D method, Particle Imaging Velocimetry, to three dimensions by encoding depth into color. The encoding is achieved by illuminating the flow volume with a continuum of light planes (a

  4. Application of 2D and 3D image technologies to characterise morphological attributes of grapevine clusters.

    Science.gov (United States)

    Tello, Javier; Cubero, Sergio; Blasco, José; Tardaguila, Javier; Aleixos, Nuria; Ibáñez, Javier

    2016-10-01

    Grapevine cluster morphology influences the quality and commercial value of wine and table grapes. It is routinely evaluated by subjective and inaccurate methods that do not meet the requirements set by the food industry. Novel two-dimensional (2D) and three-dimensional (3D) machine vision technologies emerge as promising tools for its automatic and fast evaluation. The automatic evaluation of cluster length, width and elongation was successfully achieved by the analysis of 2D images, significant and strong correlations with the manual methods being found (r = 0.959, 0.861 and 0.852, respectively). The classification of clusters according to their shape can be achieved by evaluating their conicity in different sections of the cluster. The geometric reconstruction of the morphological volume of the cluster from 2D features worked better than the direct 3D laser scanning system, showing a high correlation (r = 0.956) with the manual approach (water displacement method). In addition, we constructed and validated a simple linear regression model for cluster compactness estimation. It showed a high predictive capacity for both the training and validation subsets of clusters (R(2)  = 84.5 and 71.1%, respectively). The methodologies proposed in this work provide continuous and accurate data for the fast and objective characterisation of cluster morphology. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  5. Development of 3-D Medical Image VIsualization System

    African Journals Online (AJOL)

    User

    uses standard 2-D medical imaging inputs and generates medical images of human body parts ... light wave from points on the 3-D object(s) in ... tools, and communication bandwidth cannot .... locations along the track that correspond with.

  6. Real-time intensity based 2D/3D registration using kV-MV image pairs for tumor motion tracking in image guided radiotherapy

    Science.gov (United States)

    Furtado, H.; Steiner, E.; Stock, M.; Georg, D.; Birkfellner, W.

    2014-03-01

    Intra-fractional respiratorymotion during radiotherapy is one of themain sources of uncertainty in dose application creating the need to extend themargins of the planning target volume (PTV). Real-time tumormotion tracking by 2D/3D registration using on-board kilo-voltage (kV) imaging can lead to a reduction of the PTV. One limitation of this technique when using one projection image, is the inability to resolve motion along the imaging beam axis. We present a retrospective patient study to investigate the impact of paired portal mega-voltage (MV) and kV images, on registration accuracy. We used data from eighteen patients suffering from non small cell lung cancer undergoing regular treatment at our center. For each patient we acquired a planning CT and sequences of kV and MV images during treatment. Our evaluation consisted of comparing the accuracy of motion tracking in 6 degrees-of-freedom(DOF) using the anterior-posterior (AP) kV sequence or the sequence of kV-MV image pairs. We use graphics processing unit rendering for real-time performance. Motion along cranial-caudal direction could accurately be extracted when using only the kV sequence but in AP direction we obtained large errors. When using kV-MV pairs, the average error was reduced from 3.3 mm to 1.8 mm and the motion along AP was successfully extracted. The mean registration time was of 190+/-35ms. Our evaluation shows that using kVMV image pairs leads to improved motion extraction in 6 DOF. Therefore, this approach is suitable for accurate, real-time tumor motion tracking with a conventional LINAC.

  7. Imaging Agonist-Induced D2/D3 Receptor Desensitization and Internalization In Vivo with PET/fMRI.

    Science.gov (United States)

    Sander, Christin Y; Hooker, Jacob M; Catana, Ciprian; Rosen, Bruce R; Mandeville, Joseph B

    2016-04-01

    This study investigated the dynamics of dopamine receptor desensitization and internalization, thereby proposing a new technique for non-invasive, in vivo measurements of receptor adaptations. The D2/D3 agonist quinpirole, which induces receptor internalization in vitro, was administered at graded doses in non-human primates while imaging with simultaneous positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). A pronounced temporal divergence between receptor occupancy and fMRI signal was observed: occupancy remained elevated while fMRI responded transiently. Analogous experiments with an antagonist (prochlorperazine) and a lower-affinity agonist (ropinirole) exhibited reduced temporal dissociation between occupancy and function, consistent with a mechanism of desensitization and internalization that depends upon drug efficacy and affinity. We postulated a model that incorporates internalization into a neurovascular-coupling relationship. This model yielded in vivo desensitization/internalization rates (0.2/min for quinpirole) consistent with published in vitro measurements. Overall, these results suggest that simultaneous PET/fMRI enables characterization of dynamic neuroreceptor adaptations in vivo, and may offer a first non-invasive method for assessing receptor desensitization and internalization.

  8. Determining ice water content from 2D crystal images in convective cloud systems

    Science.gov (United States)

    Leroy, Delphine; Coutris, Pierre; Fontaine, Emmanuel; Schwarzenboeck, Alfons; Strapp, J. Walter

    2016-04-01

    Cloud microphysical in-situ instrumentation measures bulk parameters like total water content (TWC) and/or derives particle size distributions (PSD) (utilizing optical spectrometers and optical array probes (OAP)). The goal of this work is to introduce a comprehensive methodology to compute TWC from OAP measurements, based on the dataset collected during recent HAIC (High Altitude Ice Crystals)/HIWC (High Ice Water Content) field campaigns. Indeed, the HAIC/HIWC field campaigns in Darwin (2014) and Cayenne (2015) provide a unique opportunity to explore the complex relationship between cloud particle mass and size in ice crystal environments. Numerous mesoscale convective systems (MCSs) were sampled with the French Falcon 20 research aircraft at different temperature levels from -10°C up to 50°C. The aircraft instrumentation included an IKP-2 (isokinetic probe) to get reliable measurements of TWC and the optical array probes 2D-S and PIP recording images over the entire ice crystal size range. Based on the known principle relating crystal mass and size with a power law (m=α•Dβ), Fontaine et al. (2014) performed extended 3D crystal simulations and thereby demonstrated that it is possible to estimate the value of the exponent β from OAP data, by analyzing the surface-size relationship for the 2D images as a function of time. Leroy et al. (2015) proposed an extended version of this method that produces estimates of β from the analysis of both the surface-size and perimeter-size relationships. Knowing the value of β, α then is deduced from the simultaneous IKP-2 TWC measurements for the entire HAIC/HIWC dataset. The statistical analysis of α and β values for the HAIC/HIWC dataset firstly shows that α is closely linked to β and that this link changes with temperature. From these trends, a generalized parameterization for α is proposed. Finally, the comparison with the initial IKP-2 measurements demonstrates that the method is able to predict TWC values

  9. Comparison of 3D vs. 2D fast spin echo imaging for evaluation of articular cartilage in the knee on a 3 T system scientific research

    International Nuclear Information System (INIS)

    Milewski, Matthew D.; Smitaman, Edward; Moukaddam, Hicham; Katz, Lee D.; Essig, David A.; Medvecky, Michael J.; Haims, Andrew H.

    2012-01-01

    Highlights: ► Compared 3D to 2D MR sequences for articular cartilage in the knee. ► 3D imaging acquired in a single plane, 2D acquired in 3 separate planes. ► No significant difference in accuracy between 3D and 2D sequences. - Abstract: Purpose: We sought to retrospectively compare the accuracy of a three-dimensional fat-suppressed, fast spin-echo sequences acquired in the sagittal plane, with multiplanar reconstructions to that of two-dimensional fat-suppressed, fast spin echo sequences acquired in three planes on a 3 T MR system for the evaluation of articular cartilage in the knee. Materials and methods: Our study group consisted of all patients (N = 34) that underwent 3 T MR imaging of the knee at our institution with subsequent arthroscopy over an 18-month period. There were 21 males and 13 females with an average age of 36 years. MR images were reviewed by 3 musculoskeletal radiologists, blinded to operative results. 3D and 2D sequences were reviewed at different sittings separated by 4 weeks to prevent bias. Six cartilage surfaces were evaluated both with MR imaging and arthroscopically with a modified Noyes scoring system and arthroscopic results were used as the gold standard. Sensitivity, specificity, and accuracy were calculated for each reader along with Fleiss Kappa assessment agreement between the readers. Accuracies for each articular surface were compared using a difference in proportions test with a 95% confidence interval and statistical significance was calculated using a Fisher's Exact Test. Results: Two hundred and four articular surfaces were evaluated and 49 articular cartilage lesions were present at arthroscopy. For the patellofemoral surfaces, the sensitivity, specificity, and accuracy were 76.5%, 83%, and 78.2% for the 3D sequences and were 82.3%, 76%, and 82% respectively for the 2D sequences. For the medial compartment surfaces, the sensitivity, specificity, and accuracy were 81.1%, 65.1%, and 78.5% for the 3D sequences and were

  10. Multi-2D seismic imaging of the Solfatara crater (Campi Flegrei Caldera, southern Italy) from active seismic data

    Science.gov (United States)

    Gammaldi, S.; Amoroso, O.; D'Auria, L.; Zollo, A.

    2017-12-01

    Campi Flegrei is an active caldera characterized by secular, periodic episodes of spatially extended, low-rate ground deformation (bradyseism) accompanied by an intense seismic and geothermal activity. Its inner crater Solfatara is characterized by diffuse surface degassing and continuous fumarole activity. This points out the relevance of fluid and heat transport from depth and prompts for further research to improve the understanding of the hydrothermal system feeding processes and fluid migration to the surface. The experiment Repeated Induced Earthquake and Noise (RICEN) (EU Project MEDSUV), was carried out between September 2013 and November 2014 to investigate the space and time varying properties of the subsoil beneath the crater. The processed dataset consists of records from two 1D orthogonal seismic arrays deployed along WNW-ESE and NNE-SSW directions crossing the 400 m crater surface. To highlight the first P-wave arrivals a bandpass filter and an AGC were applied which allowed the detection of 17894 manually picked arrival times. Starting from a 1D velocity model, we performed a 2D non-linear Bayesian estimation. The method consists in retrieving the velocity model searching for the maximum of the "a posteriori" probability density function. The optimization is performed by the sequential use of the Genetic Algorithm and the Simplex methods. The retrieved images provide evidence for a very low P-velocity layer (Vp<500 m/s) associated with quaternary deposits, a low velocity (Vp=500-1500 m/s) water saturated deep layer at West, contrasted by a high velocity (Vp=2000-3200 m/s) layer correlated with a consolidated tephra deposit. The transition velocity range (from 1500 to 2000 m/s) suggests the possible presence of a gas-rich, accumulation volume. Based on the surface evidence of the gas released by the Bocca Grande and Bocca Nuova fumaroles at the Eastern border of Solfatara and the presence of the central deeper plume, we infer a detailed image for the

  11. SPECT imaging of D{sub 2} dopamine receptors and endogenous dopamine release in mice

    Energy Technology Data Exchange (ETDEWEB)

    Jongen, Cynthia [University Medical Center Utrecht, Image Sciences Institute, Q0S.459, P.O. Box 85500, Utrecht (Netherlands); Bruin, Kora de; Booij, Jan [University of Amsterdam, Academic Medical Center, Department of Nuclear Medicine, Amsterdam (Netherlands); Beekman, Freek [University Medical Center Utrecht, Image Sciences Institute, Q0S.459, P.O. Box 85500, Utrecht (Netherlands); University Medical Center Utrecht, Department of Neuroscience and Pharmacology, Utrecht (Netherlands); Technical University Delft, Department R3, Section Radiation, Detection and Matter, Delft (Netherlands)

    2008-09-15

    The dopamine D{sub 2} receptor (D2R) is important in the mediation of addiction. [{sup 123}I]iodobenzamide (IBZM), a SPECT ligand for the D2R, has been used for in vivo studies of D2R availability in humans, monkeys, and rats. Although mouse models are important in the study of addiction, [{sup 123}I]IBZM has not been used in mice SPECT studies. This study evaluates the use of [{sup 123}I]IBZM for measuring D2R availability in mice. Pharmacokinetics of [{sup 123}I]IBZM in mice were studied with pinhole SPECT imaging after intravenous (i.v.) injection of [{sup 123}I]IBZM (20, 40, and 70 MBq). In addition, the ability to measure the release of endogenous dopamine after amphetamine administration with [{sup 123}I]IBZM SPECT was investigated. Thirdly, i.v. administration, the standard route of administration, and intraperitoneal (i.p.) administration of [{sup 123}I]IBZM were compared. Specific binding of [{sup 123}I]IBZM within the mouse striatum could be clearly visualized with SPECT. Peak specific striatal binding ratios were reached around 90 min post-injection. After amphetamine administration, the specific binding ratios of [{sup 123}I]IBZM decreased significantly (-27.2%; n=6; p=0.046). Intravenous administration of [{sup 123}I]IBZM led to significantly higher specific binding than i.p. administration of the same dose. However, we found that i.v. administration of a dose of 70 MBq [{sup 123}I]IBZM might result in acute ethanol intoxication because ethanol is used as a preparative aid for the routine production of [{sup 123}I]IBZM. Imaging of D2R availability and endogenous dopamine release in mice is feasible using [{sup 123}I]IBZM single pinhole SPECT. Using commercially produced [{sup 123}I]IBZM, a dose of 40 MBq injected i.v. can be recommended. (orig.)

  12. Optimization of compressive 4D-spatio-spectral snapshot imaging

    Science.gov (United States)

    Zhao, Xia; Feng, Weiyi; Lin, Lihua; Su, Wu; Xu, Guoqing

    2017-10-01

    In this paper, a modified 3D computational reconstruction method in the compressive 4D-spectro-volumetric snapshot imaging system is proposed for better sensing spectral information of 3D objects. In the design of the imaging system, a microlens array (MLA) is used to obtain a set of multi-view elemental images (EIs) of the 3D scenes. Then, these elemental images with one dimensional spectral information and different perspectives are captured by the coded aperture snapshot spectral imager (CASSI) which can sense the spectral data cube onto a compressive 2D measurement image. Finally, the depth images of 3D objects at arbitrary depths, like a focal stack, are computed by inversely mapping the elemental images according to geometrical optics. With the spectral estimation algorithm, the spectral information of 3D objects is also reconstructed. Using a shifted translation matrix, the contrast of the reconstruction result is further enhanced. Numerical simulation results verify the performance of the proposed method. The system can obtain both 3D spatial information and spectral data on 3D objects using only one single snapshot, which is valuable in the agricultural harvesting robots and other 3D dynamic scenes.

  13. Integration of virtual and real scenes within an integral 3D imaging environment

    Science.gov (United States)

    Ren, Jinsong; Aggoun, Amar; McCormick, Malcolm

    2002-11-01

    The Imaging Technologies group at De Montfort University has developed an integral 3D imaging system, which is seen as the most likely vehicle for 3D television avoiding psychological effects. To create real fascinating three-dimensional television programs, a virtual studio that performs the task of generating, editing and integrating the 3D contents involving virtual and real scenes is required. The paper presents, for the first time, the procedures, factors and methods of integrating computer-generated virtual scenes with real objects captured using the 3D integral imaging camera system. The method of computer generation of 3D integral images, where the lens array is modelled instead of the physical camera is described. In the model each micro-lens that captures different elemental images of the virtual scene is treated as an extended pinhole camera. An integration process named integrated rendering is illustrated. Detailed discussion and deep investigation are focused on depth extraction from captured integral 3D images. The depth calculation method from the disparity and the multiple baseline method that is used to improve the precision of depth estimation are also presented. The concept of colour SSD and its further improvement in the precision is proposed and verified.

  14. 3D MODEL GENERATION USING OBLIQUE IMAGES ACQUIRED BY UAV

    Directory of Open Access Journals (Sweden)

    A. Lingua

    2017-07-01

    Full Text Available In recent years, many studies revealed the advantages of using airborne oblique images for obtaining improved 3D city models (including façades and building footprints. Here the acquisition and use of oblique images from a low cost and open source Unmanned Aerial Vehicle (UAV for the 3D high-level-of-detail reconstruction of historical architectures is evaluated. The critical issues of such acquisitions (flight planning strategies, ground control points distribution, etc. are described. Several problems should be considered in the flight planning: best approach to cover the whole object with the minimum time of flight; visibility of vertical structures; occlusions due to the context; acquisition of all the parts of the objects (the closest and the farthest with similar resolution; suitable camera inclination, and so on. In this paper a solution is proposed in order to acquire oblique images with one only flight. The data processing was realized using Structure-from-Motion-based approach for point cloud generation using dense image-matching algorithms implemented in an open source software. The achieved results are analysed considering some check points and some reference LiDAR data. The system was tested for surveying a historical architectonical complex: the “Sacro Mo nte di Varallo Sesia” in north-west of Italy. This study demonstrates that the use of oblique images acquired from a low cost UAV system and processed through an open source software is an effective methodology to survey cultural heritage, characterized by limited accessibility, need for detail and rapidity of the acquisition phase, and often reduced budgets.

  15. SU-D-17A-04: The Impact of Audiovisual Biofeedback On Image Quality During 4D Functional and Anatomic Imaging: Results of a Prospective Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Keall, P; Pollock, S [University of Sydney, Sydney (Australia); Yang, J; Diehn, M; Berger, J; Graves, E; Loo, B [Stanford University, Stanford, CA (United States); Yamamoto, T [UC Davis School of Medicine, Sacramento, CA (United States)

    2014-06-01

    Purpose: The ability of audiovisual (AV) biofeedback to improve breathing regularity has not previously been investigated for functional imaging studies. The purpose of this study was to investigate the impact of AV biofeedback on 4D-PET and 4D-CT image quality in a prospective clinical trial. We hypothesized that motion blurring in 4D-PET images and the number of artifacts in 4D-CT images are reduced using AV biofeedback. Methods: AV biofeedback is a real-time, interactive and personalized system designed to help a patient self-regulate his/her breathing using a patient-specific representative waveform and musical guides. In an IRB-approved prospective clinical trial, 4D-PET and 4D-CT images of 10 lung cancer patients were acquired with AV biofeedback (AV) and free breathing (FB). The 4D-PET images in 6 respiratory bins were analyzed for motion blurring by: (1) decrease of GTVPET and (2) increase of SUVmax in 4-DPET compared to 3D-PET. The 4D-CT images were analyzed for artifacts by: (1) comparing normalized cross correlation-based scores (NCCS); and (2) quantifying a visual assessment score (VAS). A two-tailed paired t-test was used to test the hypotheses. Results: The impact of AV biofeedback on 4D-PET and 4D-CT images varied widely between patients, suggesting inconsistent patient comprehension and capability. Overall, the 4D-PET decrease of GTVPET was 2.0±3.0cm3 with AV and 2.3±3.9cm{sup 3} for FB (p=0.61). The 4D-PET increase of SUVmax was 1.6±1.0 with AV and 1.1±0.8 with FB (p=0.002). The 4D-CT NCCS were 0.65±0.27 with AV and 0.60±0.32 for FB (p=0.32). The 4D-CT VAS was 0.0±2.7 (p=ns). Conclusion: A 10-patient study demonstrated a statistically significant reduction of motion blurring of AV over FB for 1/2 functional 4D-PET imaging metrics. No difference between AV and FB was found for 2 anatomic 4D-CT imaging metrics. Future studies will focus on optimizing the human-computer interface and including patient training sessions for improved

  16. SU-D-17A-04: The Impact of Audiovisual Biofeedback On Image Quality During 4D Functional and Anatomic Imaging: Results of a Prospective Clinical Trial

    International Nuclear Information System (INIS)

    Keall, P; Pollock, S; Yang, J; Diehn, M; Berger, J; Graves, E; Loo, B; Yamamoto, T

    2014-01-01

    Purpose: The ability of audiovisual (AV) biofeedback to improve breathing regularity has not previously been investigated for functional imaging studies. The purpose of this study was to investigate the impact of AV biofeedback on 4D-PET and 4D-CT image quality in a prospective clinical trial. We hypothesized that motion blurring in 4D-PET images and the number of artifacts in 4D-CT images are reduced using AV biofeedback. Methods: AV biofeedback is a real-time, interactive and personalized system designed to help a patient self-regulate his/her breathing using a patient-specific representative waveform and musical guides. In an IRB-approved prospective clinical trial, 4D-PET and 4D-CT images of 10 lung cancer patients were acquired with AV biofeedback (AV) and free breathing (FB). The 4D-PET images in 6 respiratory bins were analyzed for motion blurring by: (1) decrease of GTVPET and (2) increase of SUVmax in 4-DPET compared to 3D-PET. The 4D-CT images were analyzed for artifacts by: (1) comparing normalized cross correlation-based scores (NCCS); and (2) quantifying a visual assessment score (VAS). A two-tailed paired t-test was used to test the hypotheses. Results: The impact of AV biofeedback on 4D-PET and 4D-CT images varied widely between patients, suggesting inconsistent patient comprehension and capability. Overall, the 4D-PET decrease of GTVPET was 2.0±3.0cm3 with AV and 2.3±3.9cm 3 for FB (p=0.61). The 4D-PET increase of SUVmax was 1.6±1.0 with AV and 1.1±0.8 with FB (p=0.002). The 4D-CT NCCS were 0.65±0.27 with AV and 0.60±0.32 for FB (p=0.32). The 4D-CT VAS was 0.0±2.7 (p=ns). Conclusion: A 10-patient study demonstrated a statistically significant reduction of motion blurring of AV over FB for 1/2 functional 4D-PET imaging metrics. No difference between AV and FB was found for 2 anatomic 4D-CT imaging metrics. Future studies will focus on optimizing the human-computer interface and including patient training sessions for improved comprehension and

  17. 3D visualization of medical images for personalized learning of human anatomy

    NARCIS (Netherlands)

    Laurence Alpay; Jelle Scheurleer; Harmen Bijwaard

    2015-01-01

    to be held in Lisbon/Portugal on October 15-17, 2015 Medical imaging nowadays often yields high definition 3D images (from CT, PET, MRI, etc.). Usually these images need to be evaluated on 2D monitors. In the transition from 3D to 2D the image becomes more difficult to interpret as a whole. To aid

  18. 3D Medical Image Interpolation Based on Parametric Cubic Convolution

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    In the process of display, manipulation and analysis of biomedical image data, they usually need to be converted to data of isotropic discretization through the process of interpolation, while the cubic convolution interpolation is widely used due to its good tradeoff between computational cost and accuracy. In this paper, we present a whole concept for the 3D medical image interpolation based on cubic convolution, and the six methods, with the different sharp control parameter, which are formulated in details. Furthermore, we also give an objective comparison for these methods using data sets with the different slice spacing. Each slice in these data sets is estimated by each interpolation method and compared with the original slice using three measures: mean-squared difference, number of sites of disagreement, and largest difference. According to the experimental results, we present a recommendation for 3D medical images under the different situations in the end.

  19. MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck.

    Directory of Open Access Journals (Sweden)

    Maria Ida Iacono

    Full Text Available Computational modeling and simulations are increasingly being used to complement experimental testing for analysis of safety and efficacy of medical devices. Multiple voxel- and surface-based whole- and partial-body models have been proposed in the literature, typically with spatial resolution in the range of 1-2 mm and with 10-50 different tissue types resolved. We have developed a multimodal imaging-based detailed anatomical model of the human head and neck, named "MIDA". The model was obtained by integrating three different magnetic resonance imaging (MRI modalities, the parameters of which were tailored to enhance the signals of specific tissues: i structural T1- and T2-weighted MRIs; a specific heavily T2-weighted MRI slab with high nerve contrast optimized to enhance the structures of the ear and eye; ii magnetic resonance angiography (MRA data to image the vasculature, and iii diffusion tensor imaging (DTI to obtain information on anisotropy and fiber orientation. The unique multimodal high-resolution approach allowed resolving 153 structures, including several distinct muscles, bones and skull layers, arteries and veins, nerves, as well as salivary glands. The model offers also a detailed characterization of eyes, ears, and deep brain structures. A special automatic atlas-based segmentation procedure was adopted to include a detailed map of the nuclei of the thalamus and midbrain into the head model. The suitability of the model to simulations involving different numerical methods, discretization approaches, as well as DTI-based tensorial electrical conductivity, was examined in a case-study, in which the electric field was generated by transcranial alternating current stimulation. The voxel- and the surface-based versions of the models are freely available to the scientific community.

  20. Automated image alignment for 2D gel electrophoresis in a high-throughput proteomics pipeline.

    Science.gov (United States)

    Dowsey, Andrew W; Dunn, Michael J; Yang, Guang-Zhong

    2008-04-01

    The quest for high-throughput proteomics has revealed a number of challenges in recent years. Whilst substantial improvements in automated protein separation with liquid chromatography and mass spectrometry (LC/MS), aka 'shotgun' proteomics, have been achieved, large-scale open initiatives such as the Human Proteome Organization (HUPO) Brain Proteome Project have shown that maximal proteome coverage is only possible when LC/MS is complemented by 2D gel electrophoresis (2-DE) studies. Moreover, both separation methods require automated alignment and differential analysis to relieve the bioinformatics bottleneck and so make high-throughput protein biomarker discovery a reality. The purpose of this article is to describe a fully automatic image alignment framework for the integration of 2-DE into a high-throughput differential expression proteomics pipeline. The proposed method is based on robust automated image normalization (RAIN) to circumvent the drawbacks of traditional approaches. These use symbolic representation at the very early stages of the analysis, which introduces persistent errors due to inaccuracies in modelling and alignment. In RAIN, a third-order volume-invariant B-spline model is incorporated into a multi-resolution schema to correct for geometric and expression inhomogeneity at multiple scales. The normalized images can then be compared directly in the image domain for quantitative differential analysis. Through evaluation against an existing state-of-the-art method on real and synthetically warped 2D gels, the proposed analysis framework demonstrates substantial improvements in matching accuracy and differential sensitivity. High-throughput analysis is established through an accelerated GPGPU (general purpose computation on graphics cards) implementation. Supplementary material, software and images used in the validation are available at http://www.proteomegrid.org/rain/.

  1. Diesel combustion and emissions formation using multiple 2-D imaging diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Dec, J.E. [Sandia National Labs., Livermore, CA (United States)

    1997-12-31

    Understanding how emissions are formed during diesel combustion is central to developing new engines that can comply with increasingly stringent emission standards while maintaining or improving performance levels. Laser-based planar imaging diagnostics are uniquely capable of providing the temporally and spatially resolved information required for this understanding. Using an optically accessible research engine, a variety of two-dimensional (2-D) imaging diagnostics have been applied to investigators of direct-injection (DI) diesel combustion and emissions formation. These optical measurements have included the following laser-sheet imaging data: Mie scattering to determine liquid-phase fuel distributions, Rayleigh scattering for quantitative vapor-phase-fuel/air mixture images, laser induced incandescence (LII) for relative soot concentrations, simultaneous LII and Rayleigh scattering for relative soot particle-size distributions, planar laser-induced fluorescence (PLIF) to obtain early PAH (polyaromatic hydrocarbon) distributions, PLIF images of the OH radical that show the diffusion flame structure, and PLIF images of the NO radical showing the onset of NO{sub x} production. In addition, natural-emission chemiluminescence images were obtained to investigate autoignition. The experimental setup is described, and the image data showing the most relevant results are presented. Then the conceptual model of diesel combustion is summarized in a series of idealized schematics depicting the temporal and spatial evolution of a reacting diesel fuel jet during the time period investigated. Finally, recent PLIF images of the NO distribution are presented and shown to support the timing and location of NO formation hypothesized from the conceptual model.

  2. Interactive visualization and analysis of 3D medical images for neurosurgery

    International Nuclear Information System (INIS)

    Miyazawa, Tatsuo; Otsuki, Taisuke.

    1994-01-01

    We propose a method that makes it possible to interactively rotate and zoom a volume-rendered object and to interactively manipulate a function for transferring data values to color and opacity. The method ray-traces a Value-Intensity-Strength volume (VIS volume) instead of a color-opacity volume, and uses an adaptive refinement technique in generating images. The VIS volume tracing method can reduce by 20-90 percent the computational time of re-calculation necessitated by changing the function for transferring data values to color and opacity, and can reduce the computational time of pre-processing by 20 percent. It can also reduce the required memory space by 40 percent. The combination of VIS volume tracing and adaptive refinement method makes it possible to interactively visualize and analyze 3D medical image data. Once we can see detailed image of 3D objects to determine their orientation, we can easily manipulate the viewing and rendering parameters even while viewing rough, blurred images. The increase in the computation time for generating full-resolution images by using the adaptive refinement technique is approximately five to ten percent. Its effectiveness is evaluated by using the results of visualization for some 3D medical image data. (author)

  3. 3D Documentation of Archaeological Excavations Using Image-Based Point Cloud

    Directory of Open Access Journals (Sweden)

    Umut Ovalı

    2017-03-01

    Full Text Available Rapid progress in digital technology enables us to create three-dimensional models using digital images. Low cost, time efficiency and accurate results of this method put to question if this technique can be an alternative to conventional documentation techniques, which generally are 2D orthogonal drawings. Accurate and detailed 3D models of archaeological features have potential for many other purposes besides geometric documentation. This study presents a recent image-based three-dimensional registration technique employed in 2013 at one of the ancient city in Turkey, using “Structure from Motion” (SfM algorithms. A commercial software is applied to investigate whether this method can be used as an alternative to other techniques. Mesh model of the some section of the excavation section of the site were produced using point clouds were produced from the digital photographs. Accuracy assessment of the produced model was realized using the comparison of the directly measured coordinates of the ground control points with produced from model. Obtained results presented that the accuracy is around 1.3 cm.

  4. System analysis and simulation of airborne scannerless 3D imaging lidar

    Science.gov (United States)

    Guo, Pan; Hao, Qiwei; Chen, Siying

    2009-11-01

    Airborne non-scanned 3D imaging lidar is a recently developed method for remote sensing. The design method and flow of the system parameters round with the spatial resolution are established and explained in detail with examples. An evaluation indicator of data coverage is proposed to optimize the imaging control method. Pixel aliasing in all directions are analyzed, the possible factors cause the aliasing are stated, including the time control error, atmospheric disturbance and platform shake. At last, a parallel data output format is proposed to eliminate the timing mismatch of image data and POS parameters.

  5. Comparison of 3D and 2D FSE T2-weighted MRI in the diagnosis of deep pelvic endometriosis: Preliminary results

    International Nuclear Information System (INIS)

    Bazot, M.; Stivalet, A.; Daraï, E.; Coudray, C.; Thomassin-Naggara, I.; Poncelet, E.

    2013-01-01

    Aim: To evaluate image quality and diagnostic accuracy of two- (2D) and three-dimensional (3D) T2-weighted magnetic resonance imaging (MRI) for the evaluation of deep infiltrating endometriosis (DIE). Materials and methods: One hundred and ten consecutive patients with suspicion of endometriosis were recruited at two institutions over a 5-month period. Twenty-three women underwent surgery, 18 had DIE at histology. Two readers independently evaluated 3D and 2D MRI for image quality and diagnosis of DIE. Descriptive analysis, chi-square test for categorical or nominal variables, McNemar test for comparison between 3D and 2D T2-weighted MRI, and weighted “statistics” for intra- and interobserver agreement were used for statistical analysis. Results: Both readers found that 3D yielded significantly lower image quality than 2D MRI (p < 0.0001). Acquisition time for 3D was significantly shorter than 2D MRI (p < 0.01). 3D offered similar accuracy to diagnose DIE compared to 2D MRI. For all locations of endometriosis, a high or variable intra-observer agreement was observed for reader 1 and 2, respectively. Conclusions: Despite a lower overall image quality, 3D provides significant time saving and similar accuracy than multiplanar 2D MRI in the diagnosis of specific DIE locations.

  6. Image-Based Modeling Techniques for Architectural Heritage 3d Digitalization: Limits and Potentialities

    Science.gov (United States)

    Santagati, C.; Inzerillo, L.; Di Paola, F.

    2013-07-01

    3D reconstruction from images has undergone a revolution in the last few years. Computer vision techniques use photographs from data set collection to rapidly build detailed 3D models. The simultaneous applications of different algorithms (MVS), the different techniques of image matching, feature extracting and mesh optimization are inside an active field of research in computer vision. The results are promising: the obtained models are beginning to challenge the precision of laser-based reconstructions. Among all the possibilities we can mainly distinguish desktop and web-based packages. Those last ones offer the opportunity to exploit the power of cloud computing in order to carry out a semi-automatic data processing, thus allowing the user to fulfill other tasks on its computer; whereas desktop systems employ too much processing time and hard heavy approaches. Computer vision researchers have explored many applications to verify the visual accuracy of 3D model but the approaches to verify metric accuracy are few and no one is on Autodesk 123D Catch applied on Architectural Heritage Documentation. Our approach to this challenging problem is to compare the 3Dmodels by Autodesk 123D Catch and 3D models by terrestrial LIDAR considering different object size, from the detail (capitals, moldings, bases) to large scale buildings for practitioner purpose.

  7. A 2D eye gaze estimation system with low-resolution webcam images

    Directory of Open Access Journals (Sweden)

    Kim Jin

    2011-01-01

    Full Text Available Abstract In this article, a low-cost system for 2D eye gaze estimation with low-resolution webcam images is presented. Two algorithms are proposed for this purpose, one for the eye-ball detection with stable approximate pupil-center and the other one for the eye movements' direction detection. Eyeball is detected using deformable angular integral search by minimum intensity (DAISMI algorithm. Deformable template-based 2D gaze estimation (DTBGE algorithm is employed as a noise filter for deciding the stable movement decisions. While DTBGE employs binary images, DAISMI employs gray-scale images. Right and left eye estimates are evaluated separately. DAISMI finds the stable approximate pupil-center location by calculating the mass-center of eyeball border vertices to be employed for initial deformable template alignment. DTBGE starts running with initial alignment and updates the template alignment with resulting eye movements and eyeball size frame by frame. The horizontal and vertical deviation of eye movements through eyeball size is considered as if it is directly proportional with the deviation of cursor movements in a certain screen size and resolution. The core advantage of the system is that it does not employ the real pupil-center as a reference point for gaze estimation which is more reliable against corneal reflection. Visual angle accuracy is used for the evaluation and benchmarking of the system. Effectiveness of the proposed system is presented and experimental results are shown.

  8. Monoplane 3D-2D registration of cerebral angiograms based on multi-objective stratified optimization

    Science.gov (United States)

    Aksoy, T.; Špiclin, Ž.; Pernuš, F.; Unal, G.

    2017-12-01

    Registration of 3D pre-interventional to 2D intra-interventional medical images has an increasingly important role in surgical planning, navigation and treatment, because it enables the physician to co-locate depth information given by pre-interventional 3D images with the live information in intra-interventional 2D images such as x-ray. Most tasks during image-guided interventions are carried out under a monoplane x-ray, which is a highly ill-posed problem for state-of-the-art 3D to 2D registration methods. To address the problem of rigid 3D-2D monoplane registration we propose a novel multi-objective stratified parameter optimization, wherein a small set of high-magnitude intensity gradients are matched between the 3D and 2D images. The stratified parameter optimization matches rotation templates to depth templates, first sampled from projected 3D gradients and second from the 2D image gradients, so as to recover 3D rigid-body rotations and out-of-plane translation. The objective for matching was the gradient magnitude correlation coefficient, which is invariant to in-plane translation. The in-plane translations are then found by locating the maximum of the gradient phase correlation between the best matching pair of rotation and depth templates. On twenty pairs of 3D and 2D images of ten patients undergoing cerebral endovascular image-guided intervention the 3D to monoplane 2D registration experiments were setup with a rather high range of initial mean target registration error from 0 to 100 mm. The proposed method effectively reduced the registration error to below 2 mm, which was further refined by a fast iterative method and resulted in a high final registration accuracy (0.40 mm) and high success rate (> 96%). Taking into account a fast execution time below 10 s, the observed performance of the proposed method shows a high potential for application into clinical image-guidance systems.

  9. Optical 3D watermark based digital image watermarking for telemedicine

    Science.gov (United States)

    Li, Xiao Wei; Kim, Seok Tae

    2013-12-01

    Region of interest (ROI) of a medical image is an area including important diagnostic information and must be stored without any distortion. This algorithm for application of watermarking technique for non-ROI of the medical image preserving ROI. The paper presents a 3D watermark based medical image watermarking scheme. In this paper, a 3D watermark object is first decomposed into 2D elemental image array (EIA) by a lenslet array, and then the 2D elemental image array data is embedded into the host image. The watermark extraction process is an inverse process of embedding. The extracted EIA through the computational integral imaging reconstruction (CIIR) technique, the 3D watermark can be reconstructed. Because the EIA is composed of a number of elemental images possesses their own perspectives of a 3D watermark object. Even though the embedded watermark data badly damaged, the 3D virtual watermark can be successfully reconstructed. Furthermore, using CAT with various rule number parameters, it is possible to get many channels for embedding. So our method can recover the weak point having only one transform plane in traditional watermarking methods. The effectiveness of the proposed watermarking scheme is demonstrated with the aid of experimental results.

  10. 3D EIT image reconstruction with GREIT.

    Science.gov (United States)

    Grychtol, Bartłomiej; Müller, Beat; Adler, Andy

    2016-06-01

    Most applications of thoracic EIT use a single plane of electrodes on the chest from which a transverse image 'slice' is calculated. However, interpretation of EIT images is made difficult by the large region above and below the electrode plane to which EIT is sensitive. Volumetric EIT images using two (or more) electrode planes should help compensate, but are little used currently. The Graz consensus reconstruction algorithm for EIT (GREIT) has become popular in lung EIT. One shortcoming of the original formulation of GREIT is its restriction to reconstruction onto a 2D planar image. We present an extension of the GREIT algorithm to 3D and develop open-source tools to evaluate its performance as a function of the choice of stimulation and measurement pattern. Results show 3D GREIT using two electrode layers has significantly more uniform sensitivity profiles through the chest region. Overall, the advantages of 3D EIT are compelling.

  11. Model-based measurement of food portion size for image-based dietary assessment using 3D/2D registration

    International Nuclear Information System (INIS)

    Chen, Hsin-Chen; Yue, Yaofeng; Sun, Mingui; Jia, Wenyan; Li, Zhaoxin; Sun, Yung-Nien; Fernstrom, John D

    2013-01-01

    Dietary assessment is important in health maintenance and intervention in many chronic conditions, such as obesity, diabetes and cardiovascular disease. However, there is currently a lack of convenient methods for measuring the volume of food (portion size) in real-life settings. We present a computational method to estimate food volume from a single photographic image of food contained on a typical dining plate. First, we calculate the food location with respect to a 3D camera coordinate system using the plate as a scale reference. Then, the food is segmented automatically from the background in the image. Adaptive thresholding and snake modeling are implemented based on several image features, such as color contrast, regional color homogeneity and curve bending degree. Next, a 3D model representing the general shape of the food (e.g., a cylinder, a sphere, etc) is selected from a pre-constructed shape model library. The position, orientation and scale of the selected shape model are determined by registering the projected 3D model and the food contour in the image, where the properties of the reference are used as constraints. Experimental results using various realistically shaped foods with known volumes demonstrated satisfactory performance of our image-based food volume measurement method even if the 3D geometric surface of the food is not completely represented in the input image. (paper)

  12. Comparison of 2D and 3D Vision Gaze with Simultaneous Measurements of Accommodation and Convergence

    OpenAIRE

    Hori, Hiroki; Shiomi, Tomoki; Hasegawa, Satoshi; Takada, Hiroki; Omori, Masako; Matsuura, Yasuyuki; Ishio, Hiromu; Miyao, Masaru

    2014-01-01

    Accommodation and convergence were measured simultaneously while subjects viewed 2D and 3D images. The aim was to compare fixation distances between accommodation and convergence in young subjects while they viewed 2D and 3D images. Measurements were made three times, 40 seconds each, using 2D and 3D images. The result suggests that ocular functions during viewing of 3D images are very similar to those during natural viewing. Previously established and widely used theories, such that within a...

  13. Technique: imaging earliest tooth development in 3D using a silver-based tissue contrast agent.

    Science.gov (United States)

    Raj, Muhammad T; Prusinkiewicz, Martin; Cooper, David M L; George, Belev; Webb, M Adam; Boughner, Julia C

    2014-02-01

    Looking in microscopic detail at the 3D organization of initiating teeth within the embryonic jaw has long-proved technologically challenging because of the radio-translucency of these tiny un-mineralized oral tissues. Yet 3D image data showing changes in the physical relationships among developing tooth and jaw tissues are vital to understand the coordinated morphogenesis of vertebrate teeth and jaws as an animal grows and as species evolve. Here, we present a new synchrotron-based scanning solution to image odontogenesis in 3D and in histological detail using a silver-based contrast agent. We stained fixed, intact wild-type mice aged embryonic (E) day 10 to birth with 1% Protargol-S at 37°C for 12-32 hr. Specimens were scanned at 4-10 µm pixel size at 28 keV, just above the silver K-edge, using micro-computed tomography (µCT) at the Canadian Light Source synchrotron. Synchrotron µCT scans of silver-stained embryos showed even the earliest visible stages of tooth initiation, as well as many other tissue types and structures, in histological detail. Silver stain penetration was optimal for imaging structures in intact embryos E15 and younger. This silver stain method offers a powerful yet straightforward approach to visualize at high-resolution and in 3D the earliest stages of odontogenesis in situ, and demonstrates the important of studying the tooth organ in all three planes of view. Copyright © 2013 Wiley Periodicals, Inc.

  14. 3D IMAGING USING COHERENT SYNCHROTRON RADIATION

    Directory of Open Access Journals (Sweden)

    Peter Cloetens

    2011-05-01

    Full Text Available Three dimensional imaging is becoming a standard tool for medical, scientific and industrial applications. The use of modem synchrotron radiation sources for monochromatic beam micro-tomography provides several new features. Along with enhanced signal-to-noise ratio and improved spatial resolution, these include the possibility of quantitative measurements, the easy incorporation of special sample environment devices for in-situ experiments, and a simple implementation of phase imaging. These 3D approaches overcome some of the limitations of 2D measurements. They require new tools for image analysis.

  15. Energy-sensitive imaging detector applied to the dissociative recombination of D2H+

    International Nuclear Information System (INIS)

    Buhr, H.; Schwalm, D.; Mendes, M. B.; Novotny, O.; Berg, M. H.; Bing, D.; Krantz, C.; Orlov, D. A.; Sorg, T.; Stuetzel, J.; Varju, J.; Wolf, A.; Heber, O.; Rappaport, M. L.; Zajfman, D.

    2010-01-01

    We report on an energy-sensitive imaging detector for studying the fragmentation of polyatomic molecules in the dissociative recombination of fast molecular ions with electrons. The system is based on a large area (10x10 cm 2 ) position-sensitive, double-sided Si-strip detector with 128 horizontal and 128 vertical strips, whose pulse height information is read out individually. The setup allows us to uniquely identify fragment masses and is thus capable of measuring branching ratios between different fragmentation channels, kinetic energy releases, and breakup geometries as a function of the relative ion-electron energy. The properties of the detection system, which has been installed at the Test Storage Ring (TSR) facility of the Max-Planck Institute for Nuclear Physics in Heidelberg, is illustrated by an investigation of the dissociative recombination of the deuterated triatomic hydrogen cation D 2 H + . A huge isotope effect is observed when comparing the relative branching ratio between the D 2 + H and the HD + D channel; the ratio 2B(D 2 + H)/B(HD + D), which is measured to be 1.27±0.05 at relative electron-ion energies around 0 eV, is found to increase to 3.7±0.5 at ∼5 eV.

  16. Energy-sensitive imaging detector applied to the dissociative recombination of D2H+

    Science.gov (United States)

    Buhr, H.; Mendes, M. B.; Novotný, O.; Schwalm, D.; Berg, M. H.; Bing, D.; Heber, O.; Krantz, C.; Orlov, D. A.; Rappaport, M. L.; Sorg, T.; Stützel, J.; Varju, J.; Wolf, A.; Zajfman, D.

    2010-06-01

    We report on an energy-sensitive imaging detector for studying the fragmentation of polyatomic molecules in the dissociative recombination of fast molecular ions with electrons. The system is based on a large area (10×10 cm2) position-sensitive, double-sided Si-strip detector with 128 horizontal and 128 vertical strips, whose pulse height information is read out individually. The setup allows us to uniquely identify fragment masses and is thus capable of measuring branching ratios between different fragmentation channels, kinetic energy releases, and breakup geometries as a function of the relative ion-electron energy. The properties of the detection system, which has been installed at the Test Storage Ring (TSR) facility of the Max-Planck Institute for Nuclear Physics in Heidelberg, is illustrated by an investigation of the dissociative recombination of the deuterated triatomic hydrogen cation D2H+. A huge isotope effect is observed when comparing the relative branching ratio between the D2 + H and the HD + D channel; the ratio 2B(D2 + H)/B(HD + D), which is measured to be 1.27±0.05 at relative electron-ion energies around 0 eV, is found to increase to 3.7±0.5 at ~5 eV.

  17. 2D and 3D high resolution seismic imaging of shallow Solfatara crater in Campi Flegrei (Italy): new insights on deep hydrothermal fluid circulation processes

    Science.gov (United States)

    De Landro, Grazia; Gammaldi, Sergio; Serlenga, Vincenzo; Amoroso, Ortensia; Russo, Guido; Festa, Gaetano; D'Auria, Luca; Bruno, Pier Paolo; Gresse, Marceau; Vandemeulebrouck, Jean; Zollo, Aldo

    2017-04-01

    Seismic tomography can be used to image the spatial variation of rock properties within complex geological media such as volcanoes. Solfatara is a volcano located within the Campi Flegrei still active caldera, characterized by periodic episodes of extended, low-rate ground subsidence and uplift called bradyseism accompanied by intense seismic and geochemical activities. In particular, Solfatara is characterized by an impressive magnitude diffuse degassing, which underlines the relevance of fluid and heat transport at the crater and prompted further research to improve the understanding of the hydrothermal system feeding the surface phenomenon. In this line, an active seismic experiment, Repeated Induced Earthquake and Noise (RICEN) (EU Project MEDSUV), was carried out between September 2013 and November 2014 to provide time-varying high-resolution images of the structure of Solfatara. In this study we used the datasets provided by two different acquisition geometries: a) A 2D array cover an area of 90 x 115 m ^ 2 sampled by a regular grid of 240 vertical sensors deployed at the crater surface; b) two 1D orthogonal seismic arrays deployed along NE-SW and NW-SE directions crossing the 400 m crater surface. The arrays are sampled with a regular line of 240 receiver and 116 shots. We present 2D and 3D tomographic high-resolution P-wave velocity images obtained using two different tomographic methods adopting a multiscale strategy. The 3D image of the shallow (30-35 m) central part of Solfatara crater is performed through the iterative, linearized, tomographic inversion of the P-wave first arrival times. 2D P-wave velocity sections (60-70 m) are obtained using a non-linear travel-time tomography method based on the evaluation of a posteriori probability density with a Bayesian approach. The 3D retrieved images integrated with resistivity section and temperature and CO2 flux measurements , define the following characteristics: 1. A depth dependent P-wave velocity layer

  18. Reconstruction of incomplete cell paths through a 3D-2D level set segmentation

    Science.gov (United States)

    Hariri, Maia; Wan, Justin W. L.

    2012-02-01

    Segmentation of fluorescent cell images has been a popular technique for tracking live cells. One challenge of segmenting cells from fluorescence microscopy is that cells in fluorescent images frequently disappear. When the images are stacked together to form a 3D image volume, the disappearance of the cells leads to broken cell paths. In this paper, we present a segmentation method that can reconstruct incomplete cell paths. The key idea of this model is to perform 2D segmentation in a 3D framework. The 2D segmentation captures the cells that appear in the image slices while the 3D segmentation connects the broken cell paths. The formulation is similar to the Chan-Vese level set segmentation which detects edges by comparing the intensity value at each voxel with the mean intensity values inside and outside of the level set surface. Our model, however, performs the comparison on each 2D slice with the means calculated by the 2D projected contour. The resulting effect is to segment the cells on each image slice. Unlike segmentation on each image frame individually, these 2D contours together form the 3D level set function. By enforcing minimum mean curvature on the level set surface, our segmentation model is able to extend the cell contours right before (and after) the cell disappears (and reappears) into the gaps, eventually connecting the broken paths. We will present segmentation results of C2C12 cells in fluorescent images to illustrate the effectiveness of our model qualitatively and quantitatively by different numerical examples.

  19. Pragmatic fully 3D image reconstruction for the MiCES mouse imaging PET scanner

    International Nuclear Information System (INIS)

    Lee, Kisung; Kinahan, Paul E; Fessler, Jeffrey A; Miyaoka, Robert S; Janes, Marie; Lewellen, Tom K

    2004-01-01

    We present a pragmatic approach to image reconstruction for data from the micro crystal elements system (MiCES) fully 3D mouse imaging positron emission tomography (PET) scanner under construction at the University of Washington. Our approach is modelled on fully 3D image reconstruction used in clinical PET scanners, which is based on Fourier rebinning (FORE) followed by 2D iterative image reconstruction using ordered-subsets expectation-maximization (OSEM). The use of iterative methods allows modelling of physical effects (e.g., statistical noise, detector blurring, attenuation, etc), while FORE accelerates the reconstruction process by reducing the fully 3D data to a stacked set of independent 2D sinograms. Previous investigations have indicated that non-stationary detector point-spread response effects, which are typically ignored for clinical imaging, significantly impact image quality for the MiCES scanner geometry. To model the effect of non-stationary detector blurring (DB) in the FORE+OSEM(DB) algorithm, we have added a factorized system matrix to the ASPIRE reconstruction library. Initial results indicate that the proposed approach produces an improvement in resolution without an undue increase in noise and without a significant increase in the computational burden. The impact on task performance, however, remains to be evaluated

  20. Subnuclear foci quantification using high-throughput 3D image cytometry

    Science.gov (United States)

    Wadduwage, Dushan N.; Parrish, Marcus; Choi, Heejin; Engelward, Bevin P.; Matsudaira, Paul; So, Peter T. C.

    2015-07-01

    Ionising radiation causes various types of DNA damages including double strand breaks (DSBs). DSBs are often recognized by DNA repair protein ATM which forms gamma-H2AX foci at the site of the DSBs that can be visualized using immunohistochemistry. However most of such experiments are of low throughput in terms of imaging and image analysis techniques. Most of the studies still use manual counting or classification. Hence they are limited to counting a low number of foci per cell (5 foci per nucleus) as the quantification process is extremely labour intensive. Therefore we have developed a high throughput instrumentation and computational pipeline specialized for gamma-H2AX foci quantification. A population of cells with highly clustered foci inside nuclei were imaged, in 3D with submicron resolution, using an in-house developed high throughput image cytometer. Imaging speeds as high as 800 cells/second in 3D were achieved by using HiLo wide-field depth resolved imaging and a remote z-scanning technique. Then the number of foci per cell nucleus were quantified using a 3D extended maxima transform based algorithm. Our results suggests that while most of the other 2D imaging and manual quantification studies can count only up to about 5 foci per nucleus our method is capable of counting more than 100. Moreover we show that 3D analysis is significantly superior compared to the 2D techniques.

  1. Helical 3D-CT images of soft tissue tumors in the hand

    Energy Technology Data Exchange (ETDEWEB)

    Otani, Kazuhiro; Kikuchi, Hiraku; Tan, Akihiro; Hamanishi, Chiaki; Tanaka, Seisuke [Kinki Univ., Osaka-Sayama (Japan). School of Medicine

    2000-02-01

    X-ray, ultrasonograph CT, MRI and angiography are used to detect tumoral lesions. Recently, helical CT has been revealed to be a useful method for the diagnosis and preoperative evaluation of soft tissue tumors, by which high quality and accurate three dimensional (3D) images can be obtained quickly. We analyzed the preoperative 3D-CT images of soft tissue tumors in the hands of 11 cases (hemangioma in 6 cases, giant cell tumor, lipoma, angiofibroma, chondrosarcoma and malignant fibro-histiocytoma in one case each). Enhanced 3D-CT clearly visualized hemangiomas and solid tumors from the surrounding tissues. The tumors could easily be observed from any direction and color-coded according to the CT number. Helical 3D-CT was thus confirmed to be useful for the diagnosis and preoperative planning by indicating the details of tumor expansion into surrounding tissues. (author)

  2. Comparative Study of 2D and 3D Optical Imaging Systems: Laparoendoscopic Single-Site Surgery in an Ex Vivo Model.

    Science.gov (United States)

    Vilaça, Jaime; Pinto, José Pedro; Fernandes, Sandra; Costa, Patrício; Pinto, Jorge Correia; Leão, Pedro

    2017-12-01

    Usually laparoscopy is performed by means of a 2-dimensional (2D) image system and multiport approach. To overcome the lack of depth perception, new 3-dimensional (3D) systems are arising with the added advantage of providing stereoscopic vision. To further reduce surgery-related trauma, there are new minimally invasive surgical techniques being developed, such as LESS (laparoendoscopic single-site) surgery. The aim of this study was to compare 2D and 3D laparoscopic systems in LESS surgical procedures. All participants were selected from different levels of experience in laparoscopic surgery-10 novices, 7 intermediates, and 10 experts were included. None of the participants had had previous experience in LESS surgery. Participants were chosen randomly to begin their experience with either the 2D or 3D laparoscopic system. The exercise consisted of performing an ex vivo pork cholecystectomy through a SILS port with the assistance of a fixed distance laparoscope. Errors, time, and participants' preference were recorded. Statistical analysis of time and errors between groups was conducted with a Student's t test (using independent samples) and the Mann-Whitney test. In all 3 groups, the average time with the 2D system was significantly reduced after having used the 3D system ( P 3D system. This study suggests that the 3D system may improve the learning curve and that learning from the 3D system is transferable to the 2D environment. Additionally, the majority of participants prefer 3D equipment.

  3. Acute Cocaine Induces Fast Activation of D1 Receptor and Progressive Deactivation of D2 Receptor Strial Neurons: In Vivo Optical Microprobe [Ca2+]i Imaging

    International Nuclear Information System (INIS)

    Du, C.; Luo, Z.; Volkow, N.D.; Heintz, N.; Pan, Y.; Du, C.

    2011-01-01

    Cocaine induces fast dopamine increases in brain striatal regions, which are recognized to underlie its rewarding effects. Both dopamine D1 and D2 receptors are involved in cocaine's reward but the dynamic downstream consequences of cocaine effects in striatum are not fully understood. Here we used transgenic mice expressing EGFP under the control of either the D1 receptor (D1R) or the D2 receptor (D2R) gene and microprobe optical imaging to assess the dynamic changes in intracellular calcium ([Ca 2+ ] i ) responses (used as marker of neuronal activation) to acute cocaine in vivo separately for D1R- versus D2R-expressing neurons in striatum. Acute cocaine (8 mg/kg, i.p.) rapidly increased [Ca 2+ ] i in D1R-expressing neurons (10.6 ± 3.2%) in striatum within 8.3 ± 2.3 min after cocaine administration after which the increases plateaued; these fast [Ca 2+ ] i increases were blocked by pretreatment with a D1R antagonist (SCH23390). In contrast, cocaine induced progressive decreases in [Ca 2+ ] i in D2R-expressing neurons (10.4 ± 5.8%) continuously throughout the 30 min that followed cocaine administration; these slower [Ca 2+ ] i decreases were blocked by pretreatment with a D2R antagonist (raclopride). Since activation of striatal D1R-expressing neurons (direct-pathway) enhances cocaine reward, whereas activation of D2R expressing neurons suppresses it (indirect-pathway) (Lobo et al., 2010), this suggests that cocaine's rewarding effects entail both its fast stimulation ofD1R (resulting in abrupt activation of direct-pathway neurons) and a slower stimulation of D2R (resulting in longer-lasting deactivation of indirect-pathway neurons). We also provide direct in vivo evidence of D2R and D1R interactions in the striatal responses to acute cocaine administration.

  4. MR imaging in epilepsy with use of 3D MP-RAGE

    International Nuclear Information System (INIS)

    Tanaka, Akio; Ohno, Sigeru; Sei, Tetsuro; Kanazawa, Susumu; Yasui, Koutaro; Kuroda, Masahiro; Hiraki, Yoshio; Oka, Eiji

    1996-01-01

    The patients were 40 males and 33 females; their ages ranged from 1 month to 39 years (mean: 15.7 years). The patients underwent MR imaging, including spin-echo T 1 -weighted, turbo spin-echo proton density/T 2 -weighted, and 3D magnetization-prepared rapid gradient-echo (3D MP-RAGE) images. These examinations disclosed 39 focal abnormalities. On visual evaluation, the boundary of abnormal gray matter in the neuronal migration disorder (NMD) cases was most clealy shown on 3D MP-RAGE images as compared to the other images. This is considered to be due to the higher spatial resolution and the better contrast of the 3D MP-RAGE images than those of the other techniques. The relative contrast difference between abnormal gray matter and the adjacent white matter was also assessed. The results revealed that the contrast differences on the 3D MP-RAGE images were larger than those on the other images; this was statistically significant. Although the sensitivity of 3D MP-RAGE for NMD was not specifically evaluated in this study, the possibility of this disorder, in cases suspected on other images, could be ruled out. Thus, it appears that the specificity with respect to NMD was at least increased with us of 3D MP-RAGE. 3D MP-RAGE also enabled us to build three-dimensional surface models that were helpful in understanding the three-dimensional anatomy. Furthermore. 3D MP-RAGE was considered to be the best technique for evaluating hippocampus atrophy in patients with MTS. On the other hand, the sensitivity in the signal change of the hippocampus was higher on T 2 -weighted images. In addition, demonstration of cortical tubers of tuberous sclerosis in neurocutaneous syndrome was superior on T 2 -weighted images than on 3D MP-RAGE images. (K.H.)

  5. Intensity-based segmentation and visualization of cells in 3D microscopic images using the GPU

    Science.gov (United States)

    Kang, Mi-Sun; Lee, Jeong-Eom; Jeon, Woong-ki; Choi, Heung-Kook; Kim, Myoung-Hee

    2013-02-01

    3D microscopy images contain abundant astronomical data, rendering 3D microscopy image processing time-consuming and laborious on a central processing unit (CPU). To solve these problems, many people crop a region of interest (ROI) of the input image to a small size. Although this reduces cost and time, there are drawbacks at the image processing level, e.g., the selected ROI strongly depends on the user and there is a loss in original image information. To mitigate these problems, we developed a 3D microscopy image processing tool on a graphics processing unit (GPU). Our tool provides efficient and various automatic thresholding methods to achieve intensity-based segmentation of 3D microscopy images. Users can select the algorithm to be applied. Further, the image processing tool provides visualization of segmented volume data and can set the scale, transportation, etc. using a keyboard and mouse. However, the 3D objects visualized fast still need to be analyzed to obtain information for biologists. To analyze 3D microscopic images, we need quantitative data of the images. Therefore, we label the segmented 3D objects within all 3D microscopic images and obtain quantitative information on each labeled object. This information can use the classification feature. A user can select the object to be analyzed. Our tool allows the selected object to be displayed on a new window, and hence, more details of the object can be observed. Finally, we validate the effectiveness of our tool by comparing the CPU and GPU processing times by matching the specification and configuration.

  6. Accurate localization of intracavitary brachytherapy applicators from 3D CT imaging studies

    International Nuclear Information System (INIS)

    Lerma, F.A.; Williamson, J.F.

    2002-01-01

    Purpose: To present an accurate method to identify the positions and orientations of intracavitary (ICT) brachytherapy applicators imaged in 3D CT scans, in support of Monte Carlo photon-transport simulations, enabling accurate dose modeling in the presence of applicator shielding and interapplicator attenuation. Materials and methods: The method consists of finding the transformation that maximizes the coincidence between the known 3D shapes of each applicator component (colpostats and tandem) with the volume defined by contours of the corresponding surface on each CT slice. We use this technique to localize Fletcher-Suit CT-compatible applicators for three cervix cancer patients using post-implant CT examinations (3 mm slice thickness and separation). Dose distributions in 1-to-1 registration with the underlying CT anatomy are derived from 3D Monte Carlo photon-transport simulations incorporating each applicator's internal geometry (source encapsulation, high-density shields, and applicator body) oriented in relation to the dose matrix according to the measured localization transformations. The precision and accuracy of our localization method are assessed using CT scans, in which the positions and orientations of dense rods and spheres (in a precision-machined phantom) were measured at various orientations relative to the gantry. Results: Using this method, we register 3D Monte Carlo dose calculations directly onto post insertion patient CT studies. Using CT studies of a precisely machined phantom, the absolute accuracy of the method was found to be ±0.2 mm in plane, and ±0.3 mm in the axial direction while its precision was ±0.2 mm in plane, and ±0.2 mm axially. Conclusion: We have developed a novel, and accurate technique to localize intracavitary brachytherapy applicators in 3D CT imaging studies, which supports 3D dose planning involving detailed 3D Monte Carlo dose calculations, modeling source positions, shielding and interapplicator shielding

  7. Magnetic Resonance Angiography of the pulmonary veins: TOF 3D versus 2D

    International Nuclear Information System (INIS)

    Carriero, Alessandro; Magarelli, Nicola; Gatta, Stefania; Pinto, Dario; Bonomo, Lorenzo; Baratto, Michele; Scapati, Carmelo

    1997-01-01

    The aim of this work was to optimize the magnetic resonance angiography (MRA) technique for the selective study of the pulmonary veins. Twenty patients (13 men and 7 women; mean age: 30.5 years) were examined. MRA was performed with a 1 T superconductive magnet and the 3D time of flight (TOF) technique. Fast sequences (3D FISP : TR 58 ms, TE 6 ms, FA 20 deg, matrix 192 x 256; and 2D FLASH: TR 44 ms, TE 10 ms, FA 30 deg, matrix 192 x 256) were used. Coronal and sagittal images were submitted to MIP processing; presaturation pulses for the pulmonary arteries were located in the mediastinal region. In the right lung 3D TOF on the coronal plane well showed 124 veins, while sagittal images showed 106 veins. In the left lung, 3D TOF on the coronal plane well showed 96 vessels, while sagittal images showed 44 vessels. In the right lung, 2D TOF on the coronal plane well showed 54 veins, while sagittal images showed 36 vessels. In the left lung, 2D TOF on the coronal plane well showed 22 vessels, while sagittal images showed 21 vessels. Therefore 3D TOF yielded better than 2D TOF (p<0.05). To conclude, 3D TOF with contrast agent administration is a useful tool to study the pulmonary veins; those with a larger caliber are better depicted and the integration of coronal and sagittal images depicts more veins

  8. Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence

    Energy Technology Data Exchange (ETDEWEB)

    Ciftci, E. E-mail: eciftcis7@hotmail.com; Anik, Yonca; Arslan, Arzu; Akansel, Gur; Sarisoy, Tahsin; Demirci, Ali

    2004-09-01

    Purpose: The aim of this study is to evaluate the efficacy of the driven equilibrium radio frequency reset pulse (DRIVE) on image quality and nerve detection when used in adjunction with T2-weighted 3D turbo spin-echo (TSE) sequence. Materials and methods: Forty-five patients with cranial nerve symptoms referable to the cerebellopontine angle (CPA) were examined using a T2-weighted 3D TSE pulse sequence with and without DRIVE. MR imaging was performed on a 1.5-T MRI scanner. In addition to the axial resource images, reformatted oblique sagittal, oblique coronal and maximum intensity projection (MIP) images of the inner ear were evaluated. The nerve identification and image quality were graded for the cranial nerves V-VIII as well as inner ear structures. These structures were chosen because fluid-solid interfaces existed due to the CSF around (the cranial nerves V-VIII) or the endolymph within (the inner ear structures). Statistical analysis was performed using the Wilcoxon test. P<0.05 was considered significant. Results: The addition of the DRIVE pulse shortens the scan time by 25%. T2-weighted 3D TSE sequence with DRIVE performed slightly better than the T2-weighted 3D TSE sequence without DRIVE in identifying the individual nerves. The image quality was also slightly better with DRIVE. Conclusion: The addition of the DRIVE pulse to the T2-weighted 3D TSE sequence is preferable when imaging the cranial nerves surrounded by the CSF, or fluid-filled structures because of shorter scan time and better image quality due to reduced flow artifacts.

  9. Driven equilibrium (drive) MR imaging of the cranial nerves V-VIII: comparison with the T2-weighted 3D TSE sequence

    International Nuclear Information System (INIS)

    Ciftci, E.; Anik, Yonca; Arslan, Arzu; Akansel, Gur; Sarisoy, Tahsin; Demirci, Ali

    2004-01-01

    Purpose: The aim of this study is to evaluate the efficacy of the driven equilibrium radio frequency reset pulse (DRIVE) on image quality and nerve detection when used in adjunction with T2-weighted 3D turbo spin-echo (TSE) sequence. Materials and methods: Forty-five patients with cranial nerve symptoms referable to the cerebellopontine angle (CPA) were examined using a T2-weighted 3D TSE pulse sequence with and without DRIVE. MR imaging was performed on a 1.5-T MRI scanner. In addition to the axial resource images, reformatted oblique sagittal, oblique coronal and maximum intensity projection (MIP) images of the inner ear were evaluated. The nerve identification and image quality were graded for the cranial nerves V-VIII as well as inner ear structures. These structures were chosen because fluid-solid interfaces existed due to the CSF around (the cranial nerves V-VIII) or the endolymph within (the inner ear structures). Statistical analysis was performed using the Wilcoxon test. P<0.05 was considered significant. Results: The addition of the DRIVE pulse shortens the scan time by 25%. T2-weighted 3D TSE sequence with DRIVE performed slightly better than the T2-weighted 3D TSE sequence without DRIVE in identifying the individual nerves. The image quality was also slightly better with DRIVE. Conclusion: The addition of the DRIVE pulse to the T2-weighted 3D TSE sequence is preferable when imaging the cranial nerves surrounded by the CSF, or fluid-filled structures because of shorter scan time and better image quality due to reduced flow artifacts

  10. Level of detail in 3D city models

    NARCIS (Netherlands)

    Biljecki, F.

    2017-01-01

    The concept of level of detail (LOD) describes the content of 3D city models and it plays an essential role during their life cycle. On one hand it comes akin to the concepts of scale in cartography and LOD in computer graphics, on the other hand it is a standalone concept that requires attention.

  11. Interactive 3D audio: Enhancing awareness of details in immersive soundscapes?

    DEFF Research Database (Denmark)

    Schmidt, Mikkel Nørgaard; Schwartz, Stephen; Larsen, Jan

    2012-01-01

    Spatial audio and the possibility of interacting with the audio environment is thought to increase listeners' attention to details in a soundscape. This work examines if interactive 3D audio enhances listeners' ability to recall details in a soundscape. Nine different soundscapes were constructed...

  12. IMAGE-BASED MODELING TECHNIQUES FOR ARCHITECTURAL HERITAGE 3D DIGITALIZATION: LIMITS AND POTENTIALITIES

    Directory of Open Access Journals (Sweden)

    C. Santagati

    2013-07-01

    Full Text Available 3D reconstruction from images has undergone a revolution in the last few years. Computer vision techniques use photographs from data set collection to rapidly build detailed 3D models. The simultaneous applications of different algorithms (MVS, the different techniques of image matching, feature extracting and mesh optimization are inside an active field of research in computer vision. The results are promising: the obtained models are beginning to challenge the precision of laser-based reconstructions. Among all the possibilities we can mainly distinguish desktop and web-based packages. Those last ones offer the opportunity to exploit the power of cloud computing in order to carry out a semi-automatic data processing, thus allowing the user to fulfill other tasks on its computer; whereas desktop systems employ too much processing time and hard heavy approaches. Computer vision researchers have explored many applications to verify the visual accuracy of 3D model but the approaches to verify metric accuracy are few and no one is on Autodesk 123D Catch applied on Architectural Heritage Documentation. Our approach to this challenging problem is to compare the 3Dmodels by Autodesk 123D Catch and 3D models by terrestrial LIDAR considering different object size, from the detail (capitals, moldings, bases to large scale buildings for practitioner purpose.

  13. A symmetric image encryption scheme based on 3D chaotic cat maps

    International Nuclear Information System (INIS)

    Chen Guanrong; Mao Yaobin; Chui, Charles K.

    2004-01-01

    Encryption of images is different from that of texts due to some intrinsic features of images such as bulk data capacity and high redundancy, which are generally difficult to handle by traditional methods. Due to the exceptionally desirable properties of mixing and sensitivity to initial conditions and parameters of chaotic maps, chaos-based encryption has suggested a new and efficient way to deal with the intractable problem of fast and highly secure image encryption. In this paper, the two-dimensional chaotic cat map is generalized to 3D for designing a real-time secure symmetric encryption scheme. This new scheme employs the 3D cat map to shuffle the positions (and, if desired, grey values as well) of image pixels and uses another chaotic map to confuse the relationship between the cipher-image and the plain-image, thereby significantly increasing the resistance to statistical and differential attacks. Thorough experimental tests are carried out with detailed analysis, demonstrating the high security and fast encryption speed of the new scheme

  14. 4D XCAT phantom for multimodality imaging research

    Energy Technology Data Exchange (ETDEWEB)

    Segars, W. P.; Sturgeon, G.; Mendonca, S.; Grimes, Jason; Tsui, B. M. W. [Department of Radiology, Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, 2424 Erwin Road, Hock Plaza, Suite 302, Durham, North Carolina 27705 (United States); Department of Radiology, Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, 2424 Erwin Road, Hock Plaza, Suite 302, Durham, North Carolina 27705 and Department of Biomedical Engineering, University of North Carolina, Chapel Hill, North Carolina 27599 (United States); Department of Radiology, Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, 2424 Erwin Road, Hock Plaza, Suite 302, Durham, North Carolina 27705 (United States); The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins Medical Institutions, Baltimore, Maryland 21287 (United States)

    2010-09-15

    Purpose: The authors develop the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. Methods: Highly detailed whole-body anatomies for the adult male and female were defined in the XCAT using nonuniform rational B-spline (NURBS) and subdivision surfaces based on segmentation of the Visible Male and Female anatomical datasets from the National Library of Medicine as well as patient datasets. Using the flexibility of these surfaces, the Visible Human anatomies were transformed to match body measurements and organ volumes for a 50th percentile (height and weight) male and female. The desired body measurements for the models were obtained using the PEOPLESIZE program that contains anthropometric dimensions categorized from 1st to the 99th percentile for US adults. The desired organ volumes were determined from ICRP Publication 89 [ICRP, ''Basic anatomical and physiological data for use in radiological protection: reference values,'' ICRP Publication 89 (International Commission on Radiological Protection, New York, NY, 2002)]. The male and female anatomies serve as standard templates upon which anatomical variations may be modeled in the XCAT through user-defined parameters. Parametrized models for the cardiac and respiratory motions were also incorporated into the XCAT based on high-resolution cardiac- and respiratory-gated multislice CT data. To demonstrate the usefulness of the phantom, the authors show example simulation studies in PET, SPECT, and CT using publicly available simulation packages. Results: As demonstrated in the pilot studies, the 4D XCAT (which includes thousands of anatomical structures) can produce realistic imaging data when combined with accurate models of the imaging process. With the flexibility of the NURBS surface primitives, any number of different anatomies, cardiac or respiratory motions or patterns, and spatial resolutions can be simulated to perform imaging research. Conclusions: With the

  15. 4D XCAT phantom for multimodality imaging research

    International Nuclear Information System (INIS)

    Segars, W. P.; Sturgeon, G.; Mendonca, S.; Grimes, Jason; Tsui, B. M. W.

    2010-01-01

    Purpose: The authors develop the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. Methods: Highly detailed whole-body anatomies for the adult male and female were defined in the XCAT using nonuniform rational B-spline (NURBS) and subdivision surfaces based on segmentation of the Visible Male and Female anatomical datasets from the National Library of Medicine as well as patient datasets. Using the flexibility of these surfaces, the Visible Human anatomies were transformed to match body measurements and organ volumes for a 50th percentile (height and weight) male and female. The desired body measurements for the models were obtained using the PEOPLESIZE program that contains anthropometric dimensions categorized from 1st to the 99th percentile for US adults. The desired organ volumes were determined from ICRP Publication 89 [ICRP, ''Basic anatomical and physiological data for use in radiological protection: reference values,'' ICRP Publication 89 (International Commission on Radiological Protection, New York, NY, 2002)]. The male and female anatomies serve as standard templates upon which anatomical variations may be modeled in the XCAT through user-defined parameters. Parametrized models for the cardiac and respiratory motions were also incorporated into the XCAT based on high-resolution cardiac- and respiratory-gated multislice CT data. To demonstrate the usefulness of the phantom, the authors show example simulation studies in PET, SPECT, and CT using publicly available simulation packages. Results: As demonstrated in the pilot studies, the 4D XCAT (which includes thousands of anatomical structures) can produce realistic imaging data when combined with accurate models of the imaging process. With the flexibility of the NURBS surface primitives, any number of different anatomies, cardiac or respiratory motions or patterns, and spatial resolutions can be simulated to perform imaging research. Conclusions: With the ability to produce

  16. ImageSURF MOAB2 Image Example

    OpenAIRE

    O'Mara, Aidan R; Collins, Jessica M; King, Anna E; Vickers, James C; Kirkcaldie, Matthew T K

    2017-01-01

    A set of 2000x2000 confocal fluorescence images of MOAB2-labelled cortex from APPswe/PS1dE9 mouse models of Alzheimer's disease, sparsely annotated pixel labels and reference segmentation examples. Pixels are annotated as signal (red 0xFFFF0000) and background (blue 0xFF0000FF). Images were captured as stitched 12-bit greyscale single-plane images and cropped to size. Image acquisition was performed at 561nm excitation and 615nm emission wavelengths using a Perkin Elmer Ultraview VOX ima...

  17. A NEW METHOD FOR ESTIMATING THE 3D SIZE-DISTRIBUTIONCURVE OF FRAGMENTED ROCKS OUT OF 2D IMAGES

    Directory of Open Access Journals (Sweden)

    Souhaïl Outal

    2011-05-01

    Full Text Available Image analysis of rock fragmentation is used in mines and quarries to control the quality of blasting. Obtained information is the particle-size-distribution curve relating volume-proportions to the sizes of fragments. Calculation by image analysis of this particle-size-distribution is carried out in several steps, and each step has its inherent limitations. We will focus in this paper on one of themost crucial steps: reconstructing the volumes (3D. For the 3D-step, we have noticed that, due to the current acquisition method, there is no correlation between the average grey level of surfaces of the fragments and their third dimension. Consequently volumes (3D as well as the sizes (1D has to be calculated indirectly from the extracted projected areas of the visible fragments of images. For this purpose, we have built in laboratory a set of images of fragmented rocks resulting from blasting. Moreover, several tests based on comparisons between image analysis and screening measurements were carried out. A new stereological method, based on the comparison of the densities of probability (histograms of the samemeasurements (with very weak covering and overlappingwas elaborated. It allows us to estimate correctly, for a given type of rock, two intrinsic laws weighing the projected areas distribution in order to predict the volumic distribution.

  18. Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences

    Energy Technology Data Exchange (ETDEWEB)

    Altahawi, Faysal F.; Blount, Kevin J.; Omar, Imran M. [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Morley, Nicholas P. [Marshfield Clinic, Department of Radiology, Marshfield, WI (United States); Raithel, Esther [Siemens Healthcare GmbH, Erlangen (Germany)

    2017-01-15

    To compare a faster, new, high-resolution accelerated 3D-fast-spin-echo (3D-FSE) acquisition sequence (CS-SPACE) to traditional 2D and high-resolution 3D sequences for knee 3-T magnetic resonance imaging (MRI). Twenty patients received knee MRIs that included routine 2D (T1, PD ± FS, T2-FS; 0.5 x 0.5 x 3 mm{sup 3}; ∝10 min), traditional 3D FSE (SPACE-PD-FS; 0.5 x 0.5 x 0.5 mm{sup 3}; ∝7.5 min), and accelerated 3D-FSE prototype (CS-SPACE-PD-FS; 0.5 x 0.5 x 0.5 mm{sup 3}; ∝5 min) acquisitions on a 3-T MRI system (Siemens MAGNETOM Skyra). Three musculoskeletal radiologists (MSKRs) prospectively and independently reviewed the studies with graded surveys comparing image and diagnostic quality. Tissue-specific signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were also compared. MSKR-perceived diagnostic quality of cartilage was significantly higher for CS-SPACE than for SPACE and 2D sequences (p < 0.001). Assessment of diagnostic quality of menisci and synovial fluid was higher for CS-SPACE than for SPACE (p < 0.001). CS-SPACE was not significantly different from SPACE but had lower assessments than 2D sequences for evaluation of bones, ligaments, muscles, and fat (p ≤ 0.004). 3D sequences had higher spatial resolution, but lower overall assessed contrast (p < 0.001). Overall image quality from CS-SPACE was assessed as higher than SPACE (p = 0.007), but lower than 2D sequences (p < 0.001). Compared to SPACE, CS-SPACE had higher fluid SNR and CNR against all other tissues (all p < 0.001). The CS-SPACE prototype allows for faster isotropic acquisitions of knee MRIs over currently used protocols. High fluid-to-cartilage CNR and higher spatial resolution over routine 2D sequences may present a valuable role for CS-SPACE in the evaluation of cartilage and menisci. (orig.)

  19. High-resolution, time-resolved MRA provides superior definition of lower-extremity arterial segments compared to 2D time-of-flight imaging.

    Science.gov (United States)

    Thornton, F J; Du, J; Suleiman, S A; Dieter, R; Tefera, G; Pillai, K R; Korosec, F R; Mistretta, C A; Grist, T M

    2006-08-01

    To evaluate a novel time-resolved contrast-enhanced (CE) projection reconstruction (PR) magnetic resonance angiography (MRA) method for identifying potential bypass graft target vessels in patients with Class II-IV peripheral vascular disease. Twenty patients (M:F = 15:5, mean age = 58 years, range = 48-83 years), were recruited from routine MRA referrals. All imaging was performed on a 1.5 T MRI system with fast gradients (Signa LX; GE Healthcare, Waukesha, WI). Images were acquired with a novel technique that combined undersampled PR with a time-resolved acquisition to yield an MRA method with high temporal and spatial resolution. The method is called PR hyper time-resolved imaging of contrast kinetics (PR-hyperTRICKS). Quantitative and qualitative analyses were used to compare two-dimensional (2D) time-of-flight (TOF) and PR-hyperTRICKS in 13 arterial segments per lower extremity. Statistical analysis was performed with the Wilcoxon signed-rank test. Fifteen percent (77/517) of the vessels were scored as missing or nondiagnostic with 2D TOF, but were scored as diagnostic with PR-hyperTRICKS. Image quality was superior with PR-hyperTRICKS vs. 2D TOF (on a four-point scale, mean rank = 3.3 +/- 1.2 vs. 2.9 +/- 1.2, P < 0.0001). PR-hyperTRICKS produced images with high contrast-to-noise ratios (CNR) and high spatial and temporal resolution. 2D TOF images were of inferior quality due to moderate spatial resolution, inferior CNR, greater flow-related artifacts, and absence of temporal resolution. PR-hyperTRICKS provides superior preoperative assessment of lower limb ischemia compared to 2D TOF.

  20. Simplifying the Exploration of Volumetric Images: Development of a 3D User Interface for the Radiologist’s Workplace

    OpenAIRE

    Teistler, M.; Breiman, R. S.; Lison, T.; Bott, O. J.; Pretschner, D. P.; Aziz, A.; Nowinski, W. L.

    2007-01-01

    Volumetric imaging (computed tomography and magnetic resonance imaging) provides increased diagnostic detail but is associated with the problem of navigation through large amounts of data. In an attempt to overcome this problem, a novel 3D navigation tool has been designed and developed that is based on an alternative input device. A 3D mouse allows for simultaneous definition of position and orientation of orthogonal or oblique multiplanar reformatted images or slabs, which are presented wit...

  1. Passive 3D imaging of nuclear waste containers with Muon Scattering Tomography

    Science.gov (United States)

    Thomay, C.; Velthuis, J.; Poffley, T.; Baesso, P.; Cussans, D.; Frazão, L.

    2016-03-01

    The non-invasive imaging of dense objects is of particular interest in the context of nuclear waste management, where it is important to know the contents of waste containers without opening them. Using Muon Scattering Tomography (MST), it is possible to obtain a detailed 3D image of the contents of a waste container on reasonable timescales, showing both the high and low density materials inside. We show the performance of such a method on a Monte Carlo simulation of a dummy waste drum object containing objects of different shapes and materials. The simulation has been tuned with our MST prototype detector performance. In particular, we show that both a tungsten penny of 2 cm radius and 1 cm thickness, and a uranium sheet of 0.5 cm thickness can be clearly identified. We also show the performance of a novel edge finding technique, by which the edges of embedded objects can be identified more precisely than by solely using the imaging method.

  2. Featured Image: A Detailed Look at the Crab Nebula

    Science.gov (United States)

    Kohler, Susanna

    2017-07-01

    Planning on watching fireworks tomorrow? Heres an astronomical firework to help you start the celebrations! A new study has stunningly detailed the Crab Nebula (click for a closer look), a nebula 6,500 light-years away thought to have been formedby a supernova explosion and the subsequent ultrarelativistic wind emitted by the pulsar at its heart. Led by Gloria Dubner (University of Buenos Aires), the authors of this study obtained new observations of the Crab Nebula from five different telescopes. They compiled these observations to compare the details of the nebulas structure across different wavelengths, which allowedthem to learnabout the sources of various features within the nebula. In the images above, thetop left shows the 3 GHz data from the Very Large Array (radio). Moving clockise, the radio data (shown in red) is composited with: infrared data from Spitzer Space Telescope, optical continuum from Hubble Space Telescope, 500-nm optical datafrom Hubble, and ultraviolet data from XMM-Newton. The final two images are of the nebula center, and they are composites of the radio imagewith X-ray data from Chandra and near-infrared data from Hubble. To read more about what Dubner and collaborators learned (and to see more spectacular images!), check out the paper below.CitationG. Dubner et al 2017 ApJ 840 82. doi:10.3847/1538-4357/aa6983

  3. Numerical correction of anti-symmetric aberrations in single HRTEM images of weakly scattering 2D-objects

    International Nuclear Information System (INIS)

    Lehtinen, Ossi; Geiger, Dorin; Lee, Zhongbo; Whitwick, Michael Brian; Chen, Ming-Wei; Kis, Andras; Kaiser, Ute

    2015-01-01

    Here, we present a numerical post-processing method for removing the effect of anti-symmetric residual aberrations in high-resolution transmission electron microscopy (HRTEM) images of weakly scattering 2D-objects. The method is based on applying the same aberrations with the opposite phase to the Fourier transform of the recorded image intensity and subsequently inverting the Fourier transform. We present the theoretical justification of the method, and its verification based on simulated images in the case of low-order anti-symmetric aberrations. Ultimately the method is applied to experimental hardware aberration-corrected HRTEM images of single-layer graphene and MoSe 2 resulting in images with strongly reduced residual low-order aberrations, and consequently improved interpretability. Alternatively, this method can be used to estimate by trial and error the residual anti-symmetric aberrations in HRTEM images of weakly scattering objects

  4. Revisiting the concept level of detail in 3D city modelling

    NARCIS (Netherlands)

    Biljecki, F.; Zhao, J.; Stoter, J.E.; Ledoux, H.

    2013-01-01

    This review paper discusses the concept of level of detail in 3D city modelling, and is a first step towards a foundation for a standardised definition. As an introduction, a few level of detail specifications, outlooks and approaches are given from the industry. The paper analyses the general

  5. High resolution, multi-2D seismic imaging of Solfatara crater (Campi Flegrei Caldera, southern Italy) from active seismic data

    Science.gov (United States)

    Gammaldi, S.; Amoroso, O.; D'Auria, L.; Zollo, A.

    2018-05-01

    A multi-2D imaging of the Solfatara Crater inside the Campi Flegrei Caldera, was obtained by the joint interpretation of geophysical evidences and the new active seismic dataset acquired during the RICEN experiment (EU project MEDSUV) in 2014. We used a total of 17,894 first P-wave arrival times manually picked on pre-processed waveforms, recorded along two 1D profiles criss-crossing the inner Solfatara crater, and performed a tomographic inversion based on a multi-scale strategy and a Bayesian estimation of velocity parameters. The resulting tomographic images provide evidence for a low velocity (500-1500 m/s) water saturated deeper layer at West near the outcropping evidence of the Fangaia, contrasted by a high velocity (2000-3200 m/s) layer correlated with a consolidated tephra deposit. The transition velocity range (1500-2000 m/s) layer suggests a possible presence of a gas-rich, accumulation volume. Thanks to the mutual P-wave velocity model, we infer a detailed image for the gas migration path to the Earth surface. The gasses coming from the deep hydrothermal plume accumulate in the central and most depressed area of the Solfatara being trapped by the meteoric water saturated layer. Therefore, the gasses are transmitted through the buried fault toward the east part of the crater, where the ring faults facilitate the release as confirmed by the fumaroles. Starting from the eastern surface evidence of the gas releasing in the Bocca Grande and Bocca Nuova fumaroles, and the presence of the central deeper plume we suggest a fault situated in the central part of the crater which seems to represent the main buried conduit among them plays a key role.

  6. T2 image contrast evaluation using three dimension sampling perfection with application optimized contrasts using different flip angle evolution (3D-SPACE)

    International Nuclear Information System (INIS)

    Yamazaki, Ryo; Hiura, Yukikazu; Tsuji, Akio; Nishiki, Shigeo; Uchikoshi, Masato

    2011-01-01

    Sampling perfection with application optimized contrasts using different flip angle evolution (3D-SPACE) sequence enables one to decrease specific absorption rate (SAR) by using variable flip angle refocusing pulse. Therefore, it is expected that the contrast obtained with 3D-SPACE sequences is different from that of spin echo (SE) images and turbo spin echo (TSE) images. The purpose of this study was to evaluate the characteristics of the signal intensity and central nervous system (CNS) image contrast in T 2 weighted 3D-SPACE. Using 3 different sequences (SE, 3D-TSE and 3D-SPACE) with repetition time (TR)/ echo time (TE)=3500/70, 90 and 115 ms, we obtained T 2 weighted magnetic resonance (MR) images of inhouse phantom and five healthy volunteers' brain. Signal intensity of the phantom which contains various T 1 and T 2 value was evaluated. Tissue contrasts of white/gray matter, cerebrospinal fluid (CSF)/subcutaneous fat and gray matter/subcutaneous fat were evaluated for a clinical image study. The phantom study showed that signal intensity in 3D-SPACE significantly decreased under a T 1 value of 250 ms. It was markedly decreased in comparison to other sequences, as effective echo time (TE) was extended. White/gray matter contrast of 3D-SPACE was the highest in all sequences. On the other hand, CSF/fat and gray matter/fat contrast of 3D-SPACE was higher than TSE but lower than SE. CNS image contrasts of 3D-SPACE were comparable to that of SE. Signal intensity had decreased in the range where T 1 and T 2 values were extremely short. (author)

  7. Featured Image: New Detail in the Toothbrush Cluster

    Science.gov (United States)

    Kohler, Susanna

    2018-01-01

    This spectacular composite (click here for the full image) reveals the galaxy cluster 1RXS J0603.3+4214, known as the Toothbrush cluster due to the shape of its most prominent radio relic. Featured in a recent publication led by Kamlesh Rajpurohit (Thuringian State Observatory, Germany), this image contains new Very Large Array (VLA) 1.5-GHz observations (red) showing the radio emission within the cluster. This is composited with a Chandra view of the X-ray emitting gas of the cluster (blue) and an optical image of the background from Subaru data. The new deep VLA data totaling 26 hours of observations provides a detailed look at the complex structure within the Toothbrush relic, revealing enigmatic filaments and twists (see below). This new data will help us to explore the possible merger history of this cluster, which is theorized to have caused the unusual shapes we see today. For more information, check out the original article linked below.High resolution VLA 12 GHz image of the Toothbrush showing the complex, often filamentary structures. [Rajpurohit et al. 2018]CitationK. Rajpurohit et al 2018 ApJ 852 65. doi:10.3847/1538-4357/aa9f13

  8. A statistical shape modelling framework to extract 3D shape biomarkers from medical imaging data: assessing arch morphology of repaired coarctation of the aorta.

    Science.gov (United States)

    Bruse, Jan L; McLeod, Kristin; Biglino, Giovanni; Ntsinjana, Hopewell N; Capelli, Claudio; Hsia, Tain-Yen; Sermesant, Maxime; Pennec, Xavier; Taylor, Andrew M; Schievano, Silvia

    2016-05-31

    Medical image analysis in clinical practice is commonly carried out on 2D image data, without fully exploiting the detailed 3D anatomical information that is provided by modern non-invasive medical imaging techniques. In this paper, a statistical shape analysis method is presented, which enables the extraction of 3D anatomical shape features from cardiovascular magnetic resonance (CMR) image data, with no need for manual landmarking. The method was applied to repaired aortic coarctation arches that present complex shapes, with the aim of capturing shape features as biomarkers of potential functional relevance. The method is presented from the user-perspective and is evaluated by comparing results with traditional morphometric measurements. Steps required to set up the statistical shape modelling analyses, from pre-processing of the CMR images to parameter setting and strategies to account for size differences and outliers, are described in detail. The anatomical mean shape of 20 aortic arches post-aortic coarctation repair (CoA) was computed based on surface models reconstructed from CMR data. By analysing transformations that deform the mean shape towards each of the individual patient's anatomy, shape patterns related to differences in body surface area (BSA) and ejection fraction (EF) were extracted. The resulting shape vectors, describing shape features in 3D, were compared with traditionally measured 2D and 3D morphometric parameters. The computed 3D mean shape was close to population mean values of geometric shape descriptors and visually integrated characteristic shape features associated with our population of CoA shapes. After removing size effects due to differences in body surface area (BSA) between patients, distinct 3D shape features of the aortic arch correlated significantly with EF (r = 0.521, p = .022) and were well in agreement with trends as shown by traditional shape descriptors. The suggested method has the potential to discover

  9. 3D ultrasound Nakagami imaging for radiation-induced vaginal fibrosis

    Science.gov (United States)

    Yang, Xiaofeng; Rossi, Peter; Shelton, Joseph; Bruner, Debrorah; Tridandapani, Srini; Liu, Tian

    2014-03-01

    Radiation-induced vaginal fibrosis is a debilitating side-effect affecting up to 80% of women receiving radiotherapy for their gynecological (GYN) malignancies. Despite the significant incidence and severity, little research has been conducted to identify the pathophysiologic changes of vaginal toxicity. In a previous study, we have demonstrated that ultrasound Nakagami shape and PDF parameters can be used to quantify radiation-induced vaginal toxicity. These Nakagami parameters are derived from the statistics of ultrasound backscattered signals to capture the physical properties (e.g., arrangement and distribution) of the biological tissues. In this paper, we propose to expand this Nakagami imaging concept from 2D to 3D to fully characterize radiation-induced changes to the vaginal wall within the radiation treatment field. A pilot study with 5 post-radiotherapy GYN patients was conducted using a clinical ultrasound scanner (6 MHz) with a mechanical stepper. A serial of 2D ultrasound images, with radio-frequency (RF) signals, were acquired at 1 mm step size. The 2D Nakagami shape and PDF parameters were calculated from the RF signal envelope with a sliding window, and then 3D Nakagami parameter images were generated from the parallel 2D images. This imaging method may be useful as we try to monitor radiation-induced vaginal injury, and address vaginal toxicities and sexual dysfunction in women after radiotherapy for GYN malignancies.

  10. Segmentation, Reconstruction, and Analysis of Blood Thrombus Formation in 3D 2-Photon Microscopy Images

    Directory of Open Access Journals (Sweden)

    Xu Zhiliang

    2010-01-01

    Full Text Available We study the problem of segmenting, reconstructing, and analyzing the structure growth of thrombi (clots in blood vessels in vivo based on 2-photon microscopic image data. First, we develop an algorithm for segmenting clots in 3D microscopic images based on density-based clustering and methods for dealing with imaging artifacts. Next, we apply the union-of-balls (or alpha-shape algorithm to reconstruct the boundary of clots in 3D. Finally, we perform experimental studies and analysis on the reconstructed clots and obtain quantitative data of thrombus growth and structures. We conduct experiments on laser-induced injuries in vessels of two types of mice (the wild type and the type with low levels of coagulation factor VII and analyze and compare the developing clot structures based on their reconstructed clots from image data. The results we obtain are of biomedical significance. Our quantitative analysis of the clot composition leads to better understanding of the thrombus development, and is valuable to the modeling and verification of computational simulation of thrombogenesis.

  11. In vivo imaging identifies temporal signature of D1 and D2 medium spiny neurons in cocaine reward.

    Science.gov (United States)

    Calipari, Erin S; Bagot, Rosemary C; Purushothaman, Immanuel; Davidson, Thomas J; Yorgason, Jordan T; Peña, Catherine J; Walker, Deena M; Pirpinias, Stephen T; Guise, Kevin G; Ramakrishnan, Charu; Deisseroth, Karl; Nestler, Eric J

    2016-03-08

    The reinforcing and rewarding properties of cocaine are attributed to its ability to increase dopaminergic transmission in nucleus accumbens (NAc). This action reinforces drug taking and seeking and leads to potent and long-lasting associations between the rewarding effects of the drug and the cues associated with its availability. The inability to extinguish these associations is a key factor contributing to relapse. Dopamine produces these effects by controlling the activity of two subpopulations of NAc medium spiny neurons (MSNs) that are defined by their predominant expression of either dopamine D1 or D2 receptors. Previous work has demonstrated that optogenetically stimulating D1 MSNs promotes reward, whereas stimulating D2 MSNs produces aversion. However, we still lack a clear understanding of how the endogenous activity of these cell types is affected by cocaine and encodes information that drives drug-associated behaviors. Using fiber photometry calcium imaging we define D1 MSNs as the specific population of cells in NAc that encodes information about drug associations and elucidate the temporal profile with which D1 activity is increased to drive drug seeking in response to contextual cues. Chronic cocaine exposure dysregulates these D1 signals to both prevent extinction and facilitate reinstatement of drug seeking to drive relapse. Directly manipulating these D1 signals using designer receptors exclusively activated by designer drugs prevents contextual associations. Together, these data elucidate the responses of D1- and D2-type MSNs in NAc to acute cocaine and during the formation of context-reward associations and define how prior cocaine exposure selectively dysregulates D1 signaling to drive relapse.

  12. 2D-3D Face Recognition Method Basedon a Modified CCA-PCA Algorithm

    Directory of Open Access Journals (Sweden)

    Patrik Kamencay

    2014-03-01

    Full Text Available This paper presents a proposed methodology for face recognition based on an information theory approach to coding and decoding face images. In this paper, we propose a 2D-3D face-matching method based on a principal component analysis (PCA algorithm using canonical correlation analysis (CCA to learn the mapping between a 2D face image and 3D face data. This method makes it possible to match a 2D face image with enrolled 3D face data. Our proposed fusion algorithm is based on the PCA method, which is applied to extract base features. PCA feature-level fusion requires the extraction of different features from the source data before features are merged together. Experimental results on the TEXAS face image database have shown that the classification and recognition results based on the modified CCA-PCA method are superior to those based on the CCA method. Testing the 2D-3D face match results gave a recognition rate for the CCA method of a quite poor 55% while the modified CCA method based on PCA-level fusion achieved a very good recognition score of 85%.

  13. High Resolution 3D Radar Imaging of Comet Interiors

    Science.gov (United States)

    Asphaug, E. I.; Gim, Y.; Belton, M.; Brophy, J.; Weissman, P. R.; Heggy, E.

    2012-12-01

    Knowing the interiors of comets and other primitive bodies is fundamental to our understanding of how planets formed. We have developed a Discovery-class mission formulation, Comet Radar Explorer (CORE), based on the use of previously flown planetary radar sounding techniques, with the goal of obtaining high resolution 3D images of the interior of a small primitive body. We focus on the Jupiter-Family Comets (JFCs) as these are among the most primitive bodies reachable by spacecraft. Scattered in from far beyond Neptune, they are ultimate targets of a cryogenic sample return mission according to the Decadal Survey. Other suitable targets include primitive NEOs, Main Belt Comets, and Jupiter Trojans. The approach is optimal for small icy bodies ~3-20 km diameter with spin periods faster than about 12 hours, since (a) navigation is relatively easy, (b) radar penetration is global for decameter wavelengths, and (c) repeated overlapping ground tracks are obtained. The science mission can be as short as ~1 month for a fast-rotating JFC. Bodies smaller than ~1 km can be globally imaged, but the navigation solutions are less accurate and the relative resolution is coarse. Larger comets are more interesting, but radar signal is unlikely to be reflected from depths greater than ~10 km. So, JFCs are excellent targets for a variety of reasons. We furthermore focus on the use of Solar Electric Propulsion (SEP) to rendezvous shortly after the comet's perihelion. This approach leaves us with ample power for science operations under dormant conditions beyond ~2-3 AU. This leads to a natural mission approach of distant observation, followed by closer inspection, terminated by a dedicated radar mapping orbit. Radar reflections are obtained from a polar orbit about the icy nucleus, which spins underneath. Echoes are obtained from a sounder operating at dual frequencies 5 and 15 MHz, with 1 and 10 MHz bandwidths respectively. The dense network of echoes is used to obtain global 3D

  14. Effect of out-of-plane specimen movement on strain measurement using digital-image-correlation-based video measurement in 2D and 3D

    DEFF Research Database (Denmark)

    Poling, Joel; Desai, Niranjan; Fischer, Gregor

    2018-01-01

    This study determined the effect of specimen out-of-plane movement relative to the sensor, on the accuracy of strains measured made applying 2D and 3D measurement approaches employing the state-of-the-art digital-image-correlation (DIC)-based tool iMETRUM. DIC provides a convenient and inexpensive...

  15. 2D dose distribution images of a hybrid low field MRI-γ detector

    Energy Technology Data Exchange (ETDEWEB)

    Abril, A., E-mail: ajabrilf@unal.edu.co; Agulles-Pedrós, L., E-mail: lagullesp@unal.edu.co [Medical Physics Group, Physics department, Universidad Nacional de Colombia, Bogotá (Colombia)

    2016-07-07

    The proposed hybrid system is a combination of a low field MRI and dosimetric gel as a γ detector. The readout system is based on the polymerization process induced by the gel radiation. A gel dose map is obtained which represents the functional part of hybrid image alongside with the anatomical MRI one. Both images should be taken while the patient with a radiopharmaceutical is located inside the MRI system with a gel detector matrix. A relevant aspect of this proposal is that the dosimetric gel has never been used to acquire medical images. The results presented show the interaction of the {sup 99m}Tc source with the dosimetric gel simulated in Geant4. The purpose was to obtain the planar γ 2D-image. The different source configurations are studied to explore the ability of the gel as radiation detector through the following parameters; resolution, shape definition and radio-pharmaceutical concentration.

  16. 2D dose distribution images of a hybrid low field MRI-γ detector

    International Nuclear Information System (INIS)

    Abril, A.; Agulles-Pedrós, L.

    2016-01-01

    The proposed hybrid system is a combination of a low field MRI and dosimetric gel as a γ detector. The readout system is based on the polymerization process induced by the gel radiation. A gel dose map is obtained which represents the functional part of hybrid image alongside with the anatomical MRI one. Both images should be taken while the patient with a radiopharmaceutical is located inside the MRI system with a gel detector matrix. A relevant aspect of this proposal is that the dosimetric gel has never been used to acquire medical images. The results presented show the interaction of the "9"9"mTc source with the dosimetric gel simulated in Geant4. The purpose was to obtain the planar γ 2D-image. The different source configurations are studied to explore the ability of the gel as radiation detector through the following parameters; resolution, shape definition and radio-pharmaceutical concentration.

  17. 2D dose distribution images of a hybrid low field MRI-γ detector

    Science.gov (United States)

    Abril, A.; Agulles-Pedrós, L.

    2016-07-01

    The proposed hybrid system is a combination of a low field MRI and dosimetric gel as a γ detector. The readout system is based on the polymerization process induced by the gel radiation. A gel dose map is obtained which represents the functional part of hybrid image alongside with the anatomical MRI one. Both images should be taken while the patient with a radiopharmaceutical is located inside the MRI system with a gel detector matrix. A relevant aspect of this proposal is that the dosimetric gel has never been used to acquire medical images. The results presented show the interaction of the 99mTc source with the dosimetric gel simulated in Geant4. The purpose was to obtain the planar γ 2D-image. The different source configurations are studied to explore the ability of the gel as radiation detector through the following parameters; resolution, shape definition and radio-pharmaceutical concentration.

  18. The detailed orbital-decomposed electronic structures of tetragonal ZrO2

    International Nuclear Information System (INIS)

    Zhang, Yan; Ji, Vincent; Xu, Ke-Wei

    2013-01-01

    The detailed orbital-decomposed electronic structures of the tetragonal zirconia have been investigated by using the first-principles projector augmented wave (PAW) potential within the generalized gradient approximation (GGA) as well as taking into account the on-site Coulomb repulsive interaction (GGA+U). The deviation of the minimization energy from d z =0 to d z =±0.032 for experimental lattice constants (a=3.605 Å and c=5.180 Å) confirms the alternating displacement of the oxygen atoms, which causes half of the Zr---O bonds stronger and the other half weaker compared with the bonds in symmetric (d z =0) zirconia. The distorted tetragonal environment of the eight oxygen anions around Zr site splits the five-fold degenerate d states of a free Zr atom into triply degenerate t 2g (d xy , d yz and d zx ) states and doubly degenerate e g (d z 2 and d x 2 -y 2 ) states. The additional covalent character upon Zr-O ionic bonds are resulted from the hybridization between the O(2s), O(2p) and Zr(5s), triply degenerate t 2g (d xy , d yz and d zx ) states of Zr(4d). The O(2s) and O(2p) states are clearly separated and no hybrid bonding states are formed

  19. 3D ultrasound imaging : Fast and cost-effective morphometry of musculoskeletal tissue

    NARCIS (Netherlands)

    Weide, Guido; Van Der Zwaard, Stephan; Huijing, Peter A.; Jaspers, Richard T.; Harlaar, Jaap

    2017-01-01

    The developmental goal of 3D ultrasound imaging (3DUS) is to engineer a modality to perform 3D morphological ultrasound analysis of human muscles. 3DUS images are constructed from calibrated freehand 2D B-mode ultrasound images, which are positioned into a voxel array. Ultrasound (US) imaging allows

  20. In vitro and in vivo evaluation of [123I]IBZM: a potential CNS D-2 dopamine receptor imaging agent

    International Nuclear Information System (INIS)

    Kung, H.F.; Pan, S.; Kung, M.P.; Billings, J.; Kasliwal, R.; Reilley, J.; Alavi, A.

    1989-01-01

    In vitro binding characteristics of a CNS dopamine D-2 receptor imaging agent, (S)-N-[(1-ethyl-2-pyrrolidinyl)] methyl-2-hydroxy-3-iodo-6-methoxybenzamide [( 125 I]IBZM), was carried out in rats. Also brain images, as well as organ biodistribution were determined in a monkey following the administration of 123 I-labeled compound. The S-(-)-I[ 125 I]IBZM showed high specific dopamine D-2 receptor binding in rat striatum (Kd = 0.426 +/- 0.082 nM, Bmax = 480 +/- 22 fmol/mg of protein). Competition of various ligands for the IBZM binding displayed the following rank order of potency: spiperone greater than S(-)IBZM much greater than R(+)IBZM greater than or equal to S(-)BZM greater than dopamine greater than ketanserin greater than SCH-23390 much greater than propranolol, norepinephrine, serotonin. In vivo planar images of a monkey injected with [ 123 I]IBZM demonstrated a high concentration in basal ganglia of brain. The ratios of activity in the basal ganglia to cerebellum and the cortex to cerebellum in monkey brain were 4.93 and 1.44, respectively, at 120 min postinjection. These preliminary results indicate that [ 123 I]IBZM is a potentially promising imaging agent for the investigation of dopamine D-2 receptors in humans

  1. Left ventricular function assessment using a fast 3D gradient echo pulse sequence: comparison to standard multi-breath hold 2D steady state free precession imaging and accounting for papillary muscles and trabeculations.

    Science.gov (United States)

    Sievers, Burkhard; Schrader, Sebastian; Rehwald, Wolfgang; Hunold, Peter; Barkhausen, Joerg; Erbel, Raimund

    2011-06-01

    Papillary muscles and trabeculae for ventricular function analysis are known to significantly contribute to accurate volume and mass measurements. Fast imaging techniques such as three-dimensional steady-state free precession (3D SSFP) are increasingly being used to speed up imaging time, but sacrifice spatial resolution. It is unknown whether 3D SSFP, despite its reduced spatial resolution, allows for exact delineation of papillary muscles and trabeculations. We therefore compared 3D SSFP ventricular function measurements to those measured from standard multi-breath hold two-dimensional steady-state free precession cine images (standard 2D SSFP). 14 healthy subjects and 14 patients with impaired left ventricularfunction underwent 1.5 Tesla cine imaging. A stack of short axis images covering the left ventricle was acquired with 2D SSFP and 3D SSFP. Left ventricular volumes, ejection fraction, and mass were determined. Analysis was performed by substracting papillary muscles and trabeculae from left ventricular volumes. In addition, reproducibility was assessed. EDV, ESV, EF, and mass were not significantly different between 2D SSFP and 3D SSFP (mean difference healthy subjects: -0.06 +/- 3.2 ml, 0.54 +/- 2.2 ml, -0.45 +/- 1.8%, and 1.13 +/- 0.8 g, respectively; patients: 1.36 +/- 2.8 ml, -0.15 3.5 ml, 0.86 +/- 2.5%, and 0.91 +/- 0.9 g, respectively; P > or = 0.095). Intra- and interobserver variability was not different for 2D SSFP (P > or = 0.64 and P > or = 0.397) and 3D SSFP (P > or = 0.53 and P > or = 0.47). Differences in volumes, EF, and mass measurements between 3D SSFP and standard 2D SSFP are very small, and not statistically significant. 3D SSFP may be used for accurate ventricular function assessment when papillary muscles and trabeculations are to be taken into account.

  2. Reconstruction, Processing and Display of 3D-Images

    International Nuclear Information System (INIS)

    Lenz, R.

    1986-01-01

    In the last few years a number of methods have been developed which can produce true 3D images, volumes of density values. We review two of these techniques (confocal microscopy and X-ray tomography) which were used in the reconstruction of some of our images. The other images came from transmission electron microscopes, gammacameras and magnetic resonance scanners. A new algorithm is suggested which uses projection onto convex sets to improve the depth resolution in the microscopy case. Since we use a TV-monitor as display device we have to project 3D volumes to 2D images. We use the following type of projections: reprojections, range images, colorcoded depth and shaded surface displays. Shaded surface displays use the surface gradient to compute the gray value in the projection. We describe how this gradient can be computed from the range image and from the original density volume. Normally we compute a whole series of projections where the volume is rotated some degrees between two projections. In a separate display session we can display these images in stereo and motion. We describe how noise reduction filters, gray value transformations, geometric manipulations, gradient filters, texture filters and binary techniques can be used to remove uninteresting points from the volume. Finally, a filter design strategy is developed which is based on the optimal basis function approach by Hummel. We show that for a large class of patterns, in images of arbitrary dimensions, the optimal basis functions are rotation-invariant operators as introduced by Danielsson in the 2D case. We also describe how the orientation of a pattern can be computed from its feature vector. (With 107 refs.) (author)

  3. Applications of 2D to 3D conversion for educational purposes

    Science.gov (United States)

    Koido, Yoshihisa; Morikawa, Hiroyuki; Shiraishi, Saki; Takeuchi, Soya; Maruyama, Wataru; Nakagori, Toshio; Hirakata, Masataka; Shinkai, Hirohisa; Kawai, Takashi

    2013-03-01

    There are three main approaches creating stereoscopic S3D content: stereo filming using two cameras, stereo rendering of 3D computer graphics, and 2D to S3D conversion by adding binocular information to 2D material images. Although manual "off-line" conversion can control the amount of parallax flexibly, 2D material images are converted according to monocular information in most cases, and the flexibility of 2D to S3D conversion has not been exploited. If the depth is expressed flexibly, comprehensions and interests from converted S3D contents are anticipated to be differed from those from 2D. Therefore, in this study we created new S3D content for education by applying 2D to S3D conversion. For surgical education, we created S3D surgical operation content under a surgeon using a partial 2D to S3D conversion technique which was expected to concentrate viewers' attention on significant areas. And for art education, we converted Ukiyoe prints; traditional Japanese artworks made from a woodcut. The conversion of this content, which has little depth information, into S3D, is expected to produce different cognitive processes from those evoked by 2D content, e.g., the excitation of interest, and the understanding of spatial information. In addition, the effects of the representation of these contents were investigated.

  4. Detailed analysis of latencies in image-based dynamic MLC tracking

    International Nuclear Information System (INIS)

    Poulsen, Per Rugaard; Cho, Byungchul; Sawant, Amit; Ruan, Dan; Keall, Paul J.

    2010-01-01

    Purpose: Previous measurements of the accuracy of image-based real-time dynamic multileaf collimator (DMLC) tracking show that the major contributor to errors is latency, i.e., the delay between target motion and MLC response. Therefore the purpose of this work was to develop a method for detailed analysis of latency contributions during image-based DMLC tracking. Methods: A prototype DMLC tracking system integrated with a linear accelerator was used for tracking a phantom with an embedded fiducial marker during treatment delivery. The phantom performed a sinusoidal motion. Real-time target localization was based on x-ray images acquired either with a portal imager or a kV imager mounted orthogonal to the treatment beam. Each image was stored in a file on the imaging workstation. A marker segmentation program opened the image file, determined the marker position in the image, and transferred it to the DMLC tracking program. This program estimated the three-dimensional target position by a single-imager method and adjusted the MLC aperture to the target position. Imaging intervals ΔT image from 150 to 1000 ms were investigated for both kV and MV imaging. After the experiments, the recorded images were synchronized with MLC log files generated by the MLC controller and tracking log files generated by the tracking program. This synchronization allowed temporal analysis of the information flow for each individual image from acquisition to completed MLC adjustment. The synchronization also allowed investigation of the MLC adjustment dynamics on a considerably finer time scale than the 50 ms time resolution of the MLC log files. Results: For ΔT image =150 ms, the total time from image acquisition to completed MLC adjustment was 380±9 ms for MV and 420±12 ms for kV images. The main part of this time was from image acquisition to completed image file writing (272 ms for MV and 309 ms for kV). Image file opening (38 ms), marker segmentation (4 ms), MLC position

  5. Detailed analysis of latencies in image-based dynamic MLC tracking

    Energy Technology Data Exchange (ETDEWEB)

    Poulsen, Per Rugaard; Cho, Byungchul; Sawant, Amit; Ruan, Dan; Keall, Paul J. [Department of Radiation Oncology, Stanford University, Stanford, California 94305 and Department of Oncology and Department of Medical Physics, Aarhus University Hospital, 8000 Aarhus (Denmark); Department of Radiation Oncology, Stanford University, Stanford, California 94305 and Department of Radiation Oncology, Asan Medical Center, Seoul 138-736 (Korea, Republic of); Department of Radiation Oncology, Stanford University, Stanford, California 94305 (United States)

    2010-09-15

    Purpose: Previous measurements of the accuracy of image-based real-time dynamic multileaf collimator (DMLC) tracking show that the major contributor to errors is latency, i.e., the delay between target motion and MLC response. Therefore the purpose of this work was to develop a method for detailed analysis of latency contributions during image-based DMLC tracking. Methods: A prototype DMLC tracking system integrated with a linear accelerator was used for tracking a phantom with an embedded fiducial marker during treatment delivery. The phantom performed a sinusoidal motion. Real-time target localization was based on x-ray images acquired either with a portal imager or a kV imager mounted orthogonal to the treatment beam. Each image was stored in a file on the imaging workstation. A marker segmentation program opened the image file, determined the marker position in the image, and transferred it to the DMLC tracking program. This program estimated the three-dimensional target position by a single-imager method and adjusted the MLC aperture to the target position. Imaging intervals {Delta}T{sub image} from 150 to 1000 ms were investigated for both kV and MV imaging. After the experiments, the recorded images were synchronized with MLC log files generated by the MLC controller and tracking log files generated by the tracking program. This synchronization allowed temporal analysis of the information flow for each individual image from acquisition to completed MLC adjustment. The synchronization also allowed investigation of the MLC adjustment dynamics on a considerably finer time scale than the 50 ms time resolution of the MLC log files. Results: For {Delta}T{sub image}=150 ms, the total time from image acquisition to completed MLC adjustment was 380{+-}9 ms for MV and 420{+-}12 ms for kV images. The main part of this time was from image acquisition to completed image file writing (272 ms for MV and 309 ms for kV). Image file opening (38 ms), marker segmentation (4 ms

  6. A 3D freehand ultrasound system for multi-view reconstructions from sparse 2D scanning planes.

    Science.gov (United States)

    Yu, Honggang; Pattichis, Marios S; Agurto, Carla; Beth Goens, M

    2011-01-20

    A significant limitation of existing 3D ultrasound systems comes from the fact that the majority of them work with fixed acquisition geometries. As a result, the users have very limited control over the geometry of the 2D scanning planes. We present a low-cost and flexible ultrasound imaging system that integrates several image processing components to allow for 3D reconstructions from limited numbers of 2D image planes and multiple acoustic views. Our approach is based on a 3D freehand ultrasound system that allows users to control the 2D acquisition imaging using conventional 2D probes.For reliable performance, we develop new methods for image segmentation and robust multi-view registration. We first present a new hybrid geometric level-set approach that provides reliable segmentation performance with relatively simple initializations and minimum edge leakage. Optimization of the segmentation model parameters and its effect on performance is carefully discussed. Second, using the segmented images, a new coarse to fine automatic multi-view registration method is introduced. The approach uses a 3D Hotelling transform to initialize an optimization search. Then, the fine scale feature-based registration is performed using a robust, non-linear least squares algorithm. The robustness of the multi-view registration system allows for accurate 3D reconstructions from sparse 2D image planes. Volume measurements from multi-view 3D reconstructions are found to be consistently and significantly more accurate than measurements from single view reconstructions. The volume error of multi-view reconstruction is measured to be less than 5% of the true volume. We show that volume reconstruction accuracy is a function of the total number of 2D image planes and the number of views for calibrated phantom. In clinical in-vivo cardiac experiments, we show that volume estimates of the left ventricle from multi-view reconstructions are found to be in better agreement with clinical

  7. Correction of patient motion in cone-beam CT using 3D-2D registration

    Science.gov (United States)

    Ouadah, S.; Jacobson, M.; Stayman, J. W.; Ehtiati, T.; Weiss, C.; Siewerdsen, J. H.

    2017-12-01

    Cone-beam CT (CBCT) is increasingly common in guidance of interventional procedures, but can be subject to artifacts arising from patient motion during fairly long (~5-60 s) scan times. We present a fiducial-free method to mitigate motion artifacts using 3D-2D image registration that simultaneously corrects residual errors in the intrinsic and extrinsic parameters of geometric calibration. The 3D-2D registration process registers each projection to a prior 3D image by maximizing gradient orientation using the covariance matrix adaptation-evolution strategy optimizer. The resulting rigid transforms are applied to the system projection matrices, and a 3D image is reconstructed via model-based iterative reconstruction. Phantom experiments were conducted using a Zeego robotic C-arm to image a head phantom undergoing 5-15 cm translations and 5-15° rotations. To further test the algorithm, clinical images were acquired with a CBCT head scanner in which long scan times were susceptible to significant patient motion. CBCT images were reconstructed using a penalized likelihood objective function. For phantom studies the structural similarity (SSIM) between motion-free and motion-corrected images was  >0.995, with significant improvement (p  values of uncorrected images. Additionally, motion-corrected images exhibited a point-spread function with full-width at half maximum comparable to that of the motion-free reference image. Qualitative comparison of the motion-corrupted and motion-corrected clinical images demonstrated a significant improvement in image quality after motion correction. This indicates that the 3D-2D registration method could provide a useful approach to motion artifact correction under assumptions of local rigidity, as in the head, pelvis, and extremities. The method is highly parallelizable, and the automatic correction of residual geometric calibration errors provides added benefit that could be valuable in routine use.

  8. Hands-on guide for 3D image creation for geological purposes

    Science.gov (United States)

    Frehner, Marcel; Tisato, Nicola

    2013-04-01

    Geological structures in outcrops or hand specimens are inherently three dimensional (3D), and therefore better understandable if viewed in 3D. While 3D models can easily be created, manipulated, and looked at from all sides on the computer screen (e.g., using photogrammetry or laser scanning data), 3D visualizations for publications or conference posters are much more challenging as they have to live in a 2D-world (i.e., on a sheet of paper). Perspective 2D visualizations of 3D models do not fully transmit the "feeling and depth of the third dimension" to the audience; but this feeling is desirable for a better examination and understanding in 3D of the structure under consideration. One of the very few possibilities to generate real 3D images, which work on a 2D display, is by using so-called stereoscopic images. Stereoscopic images are two images of the same object recorded from two slightly offset viewpoints. Special glasses and techniques have to be used to make sure that one image is seen only by one eye, and the other image is seen by the other eye, which together lead to the "3D effect". Geoscientists are often familiar with such 3D images. For example, geomorphologists traditionally view stereographic orthophotos by employing a mirror-steroscope. Nowadays, petroleum-geoscientists examine high-resolution 3D seismic data sets in special 3D visualization rooms. One of the methods for generating and viewing a stereoscopic image, which does not require a high-tech viewing device, is to create a so-called anaglyph. The principle is to overlay two images saturated in red and cyan, respectively. The two images are then viewed through red-cyan-stereoscopic glasses. This method is simple and cost-effective, but has some drawbacks in preserving colors accurately. A similar method is used in 3D movies, where polarized light or shuttering techniques are used to separate the left from the right image, which allows preserving the original colors. The advantage of red

  9. Image compression-encryption scheme based on hyper-chaotic system and 2D compressive sensing

    Science.gov (United States)

    Zhou, Nanrun; Pan, Shumin; Cheng, Shan; Zhou, Zhihong

    2016-08-01

    Most image encryption algorithms based on low-dimensional chaos systems bear security risks and suffer encryption data expansion when adopting nonlinear transformation directly. To overcome these weaknesses and reduce the possible transmission burden, an efficient image compression-encryption scheme based on hyper-chaotic system and 2D compressive sensing is proposed. The original image is measured by the measurement matrices in two directions to achieve compression and encryption simultaneously, and then the resulting image is re-encrypted by the cycle shift operation controlled by a hyper-chaotic system. Cycle shift operation can change the values of the pixels efficiently. The proposed cryptosystem decreases the volume of data to be transmitted and simplifies the keys distribution simultaneously as a nonlinear encryption system. Simulation results verify the validity and the reliability of the proposed algorithm with acceptable compression and security performance.

  10. A Novel 2D Image Compression Algorithm Based on Two Levels DWT and DCT Transforms with Enhanced Minimize-Matrix-Size Algorithm for High Resolution Structured Light 3D Surface Reconstruction

    Science.gov (United States)

    Siddeq, M. M.; Rodrigues, M. A.

    2015-09-01

    Image compression techniques are widely used on 2D image 2D video 3D images and 3D video. There are many types of compression techniques and among the most popular are JPEG and JPEG2000. In this research, we introduce a new compression method based on applying a two level discrete cosine transform (DCT) and a two level discrete wavelet transform (DWT) in connection with novel compression steps for high-resolution images. The proposed image compression algorithm consists of four steps. (1) Transform an image by a two level DWT followed by a DCT to produce two matrices: DC- and AC-Matrix, or low and high frequency matrix, respectively, (2) apply a second level DCT on the DC-Matrix to generate two arrays, namely nonzero-array and zero-array, (3) apply the Minimize-Matrix-Size algorithm to the AC-Matrix and to the other high-frequencies generated by the second level DWT, (4) apply arithmetic coding to the output of previous steps. A novel decompression algorithm, Fast-Match-Search algorithm (FMS), is used to reconstruct all high-frequency matrices. The FMS-algorithm computes all compressed data probabilities by using a table of data, and then using a binary search algorithm for finding decompressed data inside the table. Thereafter, all decoded DC-values with the decoded AC-coefficients are combined in one matrix followed by inverse two levels DCT with two levels DWT. The technique is tested by compression and reconstruction of 3D surface patches. Additionally, this technique is compared with JPEG and JPEG2000 algorithm through 2D and 3D root-mean-square-error following reconstruction. The results demonstrate that the proposed compression method has better visual properties than JPEG and JPEG2000 and is able to more accurately reconstruct surface patches in 3D.

  11. Sub-Millimeter T2 Weighted fMRI at 7 T: Comparison of 3D-GRASE and 2D SE-EPI

    Directory of Open Access Journals (Sweden)

    Valentin G. Kemper

    2015-05-01

    Full Text Available Functional magnetic resonance imaging (fMRI allows studying human brain function non-invasively up to the spatial resolution of cortical columns and layers. Most fMRI acquisitions rely on the blood oxygenation level dependent (BOLD contrast employing T2* weighted 2D multi-slice echo-planar imaging (EPI. At ultra-high magnetic field (i.e. 7 T and above, it has been shown experimentally and by simulation, that T2 weighted acquisitions yield a signal that is spatially more specific to the site of neuronal activity at the cost of functional sensitivity. This study compared two T2 weighted imaging sequences, inner-volume 3D Gradient-and-Spin-Echo (3D-GRASE and 2D Spin-Echo EPI (SE-EPI, with evaluation of their imaging point-spread function, functional specificity, and functional sensitivity at sub-millimeter resolution. Simulations and measurements of the imaging point-spread function revealed that the strongest anisotropic blurring in 3D-GRASE (along the second phase-encoding direction was about 60 % higher than the strongest anisotropic blurring in 2D SE-EPI (along the phase-encoding direction In a visual paradigm, the BOLD sensitivity of 3D-GRASE was found to be superior due to its higher temporal signal-to-noise ratio. High resolution cortical depth profiles suggested that the contrast mechanisms are similar between the two sequences, however, 2D SE-EPI had a higher surface bias owing to the higher T2* contribution of the longer in-plane EPI echo-train for full field of view compared to the reduced field of view of zoomed 3D-GRASE.

  12. Extracting 3D layout from a single image using global image structures.

    Science.gov (United States)

    Lou, Zhongyu; Gevers, Theo; Hu, Ninghang

    2015-10-01

    Extracting the pixel-level 3D layout from a single image is important for different applications, such as object localization, image, and video categorization. Traditionally, the 3D layout is derived by solving a pixel-level classification problem. However, the image-level 3D structure can be very beneficial for extracting pixel-level 3D layout since it implies the way how pixels in the image are organized. In this paper, we propose an approach that first predicts the global image structure, and then we use the global structure for fine-grained pixel-level 3D layout extraction. In particular, image features are extracted based on multiple layout templates. We then learn a discriminative model for classifying the global layout at the image-level. Using latent variables, we implicitly model the sublevel semantics of the image, which enrich the expressiveness of our model. After the image-level structure is obtained, it is used as the prior knowledge to infer pixel-wise 3D layout. Experiments show that the results of our model outperform the state-of-the-art methods by 11.7% for 3D structure classification. Moreover, we show that employing the 3D structure prior information yields accurate 3D scene layout segmentation.

  13. An L1-norm phase constraint for half-Fourier compressed sensing in 3D MR imaging.

    Science.gov (United States)

    Li, Guobin; Hennig, Jürgen; Raithel, Esther; Büchert, Martin; Paul, Dominik; Korvink, Jan G; Zaitsev, Maxim

    2015-10-01

    In most half-Fourier imaging methods, explicit phase replacement is used. In combination with parallel imaging, or compressed sensing, half-Fourier reconstruction is usually performed in a separate step. The purpose of this paper is to report that integration of half-Fourier reconstruction into iterative reconstruction minimizes reconstruction errors. The L1-norm phase constraint for half-Fourier imaging proposed in this work is compared with the L2-norm variant of the same algorithm, with several typical half-Fourier reconstruction methods. Half-Fourier imaging with the proposed phase constraint can be seamlessly combined with parallel imaging and compressed sensing to achieve high acceleration factors. In simulations and in in-vivo experiments half-Fourier imaging with the proposed L1-norm phase constraint enables superior performance both reconstruction of image details and with regard to robustness against phase estimation errors. The performance and feasibility of half-Fourier imaging with the proposed L1-norm phase constraint is reported. Its seamless combination with parallel imaging and compressed sensing enables use of greater acceleration in 3D MR imaging.

  14. 2D/3D Visual Tracker for Rover Mast

    Science.gov (United States)

    Bajracharya, Max; Madison, Richard W.; Nesnas, Issa A.; Bandari, Esfandiar; Kunz, Clayton; Deans, Matt; Bualat, Maria

    2006-01-01

    A visual-tracker computer program controls an articulated mast on a Mars rover to keep a designated feature (a target) in view while the rover drives toward the target, avoiding obstacles. Several prior visual-tracker programs have been tested on rover platforms; most require very small and well-estimated motion between consecutive image frames a requirement that is not realistic for a rover on rough terrain. The present visual-tracker program is designed to handle large image motions that lead to significant changes in feature geometry and photometry between frames. When a point is selected in one of the images acquired from stereoscopic cameras on the mast, a stereo triangulation algorithm computes a three-dimensional (3D) location for the target. As the rover moves, its body-mounted cameras feed images to a visual-odometry algorithm, which tracks two-dimensional (2D) corner features and computes their old and new 3D locations. The algorithm rejects points, the 3D motions of which are inconsistent with a rigid-world constraint, and then computes the apparent change in the rover pose (i.e., translation and rotation). The mast pan and tilt angles needed to keep the target centered in the field-of-view of the cameras (thereby minimizing the area over which the 2D-tracking algorithm must operate) are computed from the estimated change in the rover pose, the 3D position of the target feature, and a model of kinematics of the mast. If the motion between the consecutive frames is still large (i.e., 3D tracking was unsuccessful), an adaptive view-based matching technique is applied to the new image. This technique uses correlation-based template matching, in which a feature template is scaled by the ratio between the depth in the original template and the depth of pixels in the new image. This is repeated over the entire search window and the best correlation results indicate the appropriate match. The program could be a core for building application programs for systems

  15. Design of the 2D electron cyclotron emission imaging instrument for the J-TEXT tokamak.

    Science.gov (United States)

    Pan, X M; Yang, Z J; Ma, X D; Zhu, Y L; Luhmann, N C; Domier, C W; Ruan, B W; Zhuang, G

    2016-11-01

    A new 2D Electron Cyclotron Emission Imaging (ECEI) diagnostic is being developed for the J-TEXT tokamak. It will provide the 2D electron temperature information with high spatial, temporal, and temperature resolution. The new ECEI instrument is being designed to support fundamental physics investigations on J-TEXT including MHD, disruption prediction, and energy transport. The diagnostic contains two dual dipole antenna arrays corresponding to F band (90-140 GHz) and W band (75-110 GHz), respectively, and comprises a total of 256 channels. The system can observe the same magnetic surface at both the high field side and low field side simultaneously. An advanced optical system has been designed which permits the two arrays to focus on a wide continuous region or two radially separate regions with high imaging spatial resolution. It also incorporates excellent field curvature correction with field curvature adjustment lenses. An overview of the diagnostic and the technical progress including the new remote control technique are presented.

  16. Design of the 2D electron cyclotron emission imaging instrument for the J-TEXT tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Pan, X. M.; Yang, Z. J., E-mail: yangzj@hust.edu.cn; Ma, X. D.; Ruan, B. W.; Zhuang, G. [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Zhu, Y. L. [School of Physics, University of Science and Technology of China, Anhui 230026 (China); Luhmann, N. C.; Domier, C. W. [Davis Millimeter Wave Research Center, University of California, Davis, California 95616 (United States)

    2016-11-15

    A new 2D Electron Cyclotron Emission Imaging (ECEI) diagnostic is being developed for the J-TEXT tokamak. It will provide the 2D electron temperature information with high spatial, temporal, and temperature resolution. The new ECEI instrument is being designed to support fundamental physics investigations on J-TEXT including MHD, disruption prediction, and energy transport. The diagnostic contains two dual dipole antenna arrays corresponding to F band (90-140 GHz) and W band (75-110 GHz), respectively, and comprises a total of 256 channels. The system can observe the same magnetic surface at both the high field side and low field side simultaneously. An advanced optical system has been designed which permits the two arrays to focus on a wide continuous region or two radially separate regions with high imaging spatial resolution. It also incorporates excellent field curvature correction with field curvature adjustment lenses. An overview of the diagnostic and the technical progress including the new remote control technique are presented.

  17. 2D-3D registration for cranial radiation therapy using a 3D kV CBCT and a single limited field-of-view 2D kV radiograph.

    Science.gov (United States)

    Munbodh, Reshma; Knisely, Jonathan Ps; Jaffray, David A; Moseley, Douglas J

    2018-05-01

    We present and evaluate a fully automated 2D-3D intensity-based registration framework using a single limited field-of-view (FOV) 2D kV radiograph and a 3D kV CBCT for 3D estimation of patient setup errors during brain radiotherapy. We evaluated two similarity measures, the Pearson correlation coefficient on image intensity values (ICC) and maximum likelihood measure with Gaussian noise (MLG), derived from the statistics of transmission images. Pose determination experiments were conducted on 2D kV radiographs in the anterior-posterior (AP) and left lateral (LL) views and 3D kV CBCTs of an anthropomorphic head phantom. In order to minimize radiation exposure and exclude nonrigid structures from the registration, limited FOV 2D kV radiographs were employed. A spatial frequency band useful for the 2D-3D registration was identified from the bone-to-no-bone spectral ratio (BNBSR) of digitally reconstructed radiographs (DRRs) computed from the 3D kV planning CT of the phantom. The images being registered were filtered accordingly prior to computation of the similarity measures. We evaluated the registration accuracy achievable with a single 2D kV radiograph and with the registration results from the AP and LL views combined. We also compared the performance of the 2D-3D registration solutions proposed to that of a commercial 3D-3D registration algorithm, which used the entire skull for the registration. The ground truth was determined from markers affixed to the phantom and visible in the CBCT images. The accuracy of the 2D-3D registration solutions, as quantified by the root mean squared value of the target registration error (TRE) calculated over a radius of 3 cm for all poses tested, was ICC AP : 0.56 mm, MLG AP : 0.74 mm, ICC LL : 0.57 mm, MLG LL : 0.54 mm, ICC (AP and LL combined): 0.19 mm, and MLG (AP and LL combined): 0.21 mm. The accuracy of the 3D-3D registration algorithm was 0.27 mm. There was no significant difference in mean TRE for the 2D-3D registration

  18. A high-frequency transimpedance amplifier for CMOS integrated 2D CMUT array towards 3D ultrasound imaging.

    Science.gov (United States)

    Huang, Xiwei; Cheong, Jia Hao; Cha, Hyouk-Kyu; Yu, Hongbin; Je, Minkyu; Yu, Hao

    2013-01-01

    One transimpedance amplifier based CMOS analog front-end (AFE) receiver is integrated with capacitive micromachined ultrasound transducers (CMUTs) towards high frequency 3D ultrasound imaging. Considering device specifications from CMUTs, the TIA is designed to amplify received signals from 17.5MHz to 52.5MHz with center frequency at 35MHz; and is fabricated in Global Foundry 0.18-µm 30-V high-voltage (HV) Bipolar/CMOS/DMOS (BCD) process. The measurement results show that the TIA with power-supply 6V can reach transimpedance gain of 61dBΩ and operating frequency from 17.5MHz to 100MHz. The measured input referred noise is 27.5pA/√Hz. Acoustic pulse-echo testing is conducted to demonstrate the receiving functionality of the designed 3D ultrasound imaging system.

  19. Design Application Translates 2-D Graphics to 3-D Surfaces

    Science.gov (United States)

    2007-01-01

    Fabric Images Inc., specializing in the printing and manufacturing of fabric tension architecture for the retail, museum, and exhibit/tradeshow communities, designed software to translate 2-D graphics for 3-D surfaces prior to print production. Fabric Images' fabric-flattening design process models a 3-D surface based on computer-aided design (CAD) specifications. The surface geometry of the model is used to form a 2-D template, similar to a flattening process developed by NASA's Glenn Research Center. This template or pattern is then applied in the development of a 2-D graphic layout. Benefits of this process include 11.5 percent time savings per project, less material wasted, and the ability to improve upon graphic techniques and offer new design services. Partners include Exhibitgroup/Giltspur (end-user client: TAC Air, a division of Truman Arnold Companies Inc.), Jack Morton Worldwide (end-user client: Nickelodeon), as well as 3D Exhibits Inc., and MG Design Associates Corp.

  20. Fat suppression at 2D MR imaging of the hands: Dixon method versus CHESS technique and STIR sequence

    International Nuclear Information System (INIS)

    Kirchgesner, Thomas; Perlepe, Vasiliki; Michoux, Nicolas; Larbi, Ahmed; Vande Berg, Bruno

    2017-01-01

    Highlights: • Dixon yields effective fat suppression at 2D MRI of the hands. • CHESS fat suppression is less effective especially in the coronal plane. • SNR is higher with Dixon than with CHESS at T1-weighted MR imaging. • SNR is higher with CHESS than with Dixon and STIR at T2-weighted MR imaging. - Abstract: Objective: To compare the effectiveness of fat suppression and the signal-to-noise ratio (SNR) of the Dixon method with those of the CHESS (Chemical Shift-Selective) technique and STIR (Short Tau Inversion Recovery) sequence in hands of normal subjects at 2D MR imaging. Material and methods: 14 healthy volunteers (mean age of 29.4 years) consented to have both hands prospectively imaged with SE T1 Dixon, T1 CHESS, T2 Dixon, T2 CHESS and STIR sequences in a 1.5T MR scanner. Three radiologists scored the effectiveness of fat suppression in bone marrow (EFS BM ) and soft tissues (EFS ST ) in 20 joints per subject. One radiologist measured the SNR in 10 bones per subject. Statistical analysis used two-way ANOVA with random effects, paired t-test and observed agreement to assess differences in effectiveness of fat suppression, differences in SNR and inter-observer agreement. Results: EFS BM was statistically significantly higher for T1 Dixon than for T1 CHESS and for T2 Dixon than for T2 CHESS (p < 0.0001). EFS BM was significantly higher for T2 Dixon than for STIR in the coronal plane (p = 0.0020). The SNR was significantly higher for T1 Dixon than for T1 CHESS and for T2 Dixon than for STIR (p < 0.0001). The SNR was significantly lower for T2 Dixon than for T2 CHESS (p < 0.0001). Conclusion: The Dixon method yields more effective fat suppression and higher SNR than the CHESS technique at 2D T1-weighted MR imaging of the hands. At T2-weighted MR imaging, fat suppression is more effective with the Dixon method while SNR is higher with the CHESS technique.

  1. Fat suppression at 2D MR imaging of the hands: Dixon method versus CHESS technique and STIR sequence

    Energy Technology Data Exchange (ETDEWEB)

    Kirchgesner, Thomas, E-mail: Thomas.Kirchgesner@uclouvain.be; Perlepe, Vasiliki, E-mail: Vasiliki.Perlepe@uclouvain.be; Michoux, Nicolas, E-mail: Nicolas.Michoux@uclouvain.be; Larbi, Ahmed, E-mail: Ahmed.Larbi@chu-nimes.fr; Vande Berg, Bruno, E-mail: Bruno.VandeBerg@uclouvain.be

    2017-04-15

    Highlights: • Dixon yields effective fat suppression at 2D MRI of the hands. • CHESS fat suppression is less effective especially in the coronal plane. • SNR is higher with Dixon than with CHESS at T1-weighted MR imaging. • SNR is higher with CHESS than with Dixon and STIR at T2-weighted MR imaging. - Abstract: Objective: To compare the effectiveness of fat suppression and the signal-to-noise ratio (SNR) of the Dixon method with those of the CHESS (Chemical Shift-Selective) technique and STIR (Short Tau Inversion Recovery) sequence in hands of normal subjects at 2D MR imaging. Material and methods: 14 healthy volunteers (mean age of 29.4 years) consented to have both hands prospectively imaged with SE T1 Dixon, T1 CHESS, T2 Dixon, T2 CHESS and STIR sequences in a 1.5T MR scanner. Three radiologists scored the effectiveness of fat suppression in bone marrow (EFS{sup BM}) and soft tissues (EFS{sup ST}) in 20 joints per subject. One radiologist measured the SNR in 10 bones per subject. Statistical analysis used two-way ANOVA with random effects, paired t-test and observed agreement to assess differences in effectiveness of fat suppression, differences in SNR and inter-observer agreement. Results: EFS{sup BM} was statistically significantly higher for T1 Dixon than for T1 CHESS and for T2 Dixon than for T2 CHESS (p < 0.0001). EFS{sup BM} was significantly higher for T2 Dixon than for STIR in the coronal plane (p = 0.0020). The SNR was significantly higher for T1 Dixon than for T1 CHESS and for T2 Dixon than for STIR (p < 0.0001). The SNR was significantly lower for T2 Dixon than for T2 CHESS (p < 0.0001). Conclusion: The Dixon method yields more effective fat suppression and higher SNR than the CHESS technique at 2D T1-weighted MR imaging of the hands. At T2-weighted MR imaging, fat suppression is more effective with the Dixon method while SNR is higher with the CHESS technique.

  2. Gadolinium-Enhanced Three-Dimensional Magnetization - Prepared Rapid Gradient-Echo (3D MP-RAGE) Imaging is Superior to Spin-Echo Imaging in Delineating Brain Metastases

    International Nuclear Information System (INIS)

    Takeda, T.; Takeda, A.; Nagaoka, T.; Kunieda, E.; Takemasa, K.; Watanabe, M.; Hatou, T.; Oguro, S.; Katayama, M.

    2008-01-01

    Background: Precisely defining the number and location of brain metastases is very important for establishing a treatment strategy for malignancies. Although magnetic resonance imaging (MRI) is now considered the best modality, various improvements in sequences are still being made. Purpose: To prospectively compare the diagnostic ability of three-dimensional, magnetization-prepared rapid gradient-echo (3D MP-RAGE) imaging in detecting metastatic brain tumors, with that of two-dimensional spin-echo (2D SE) T1-weighted imaging. Material and Methods: A total of 123 examinations were included in this study, and 119 examinations from 88 patients with known malignancies were analyzed. All patients underwent T1- and T2-weighted 2D SE transverse imaging, followed by gadolinium-enhanced T1-weighted transverse and coronal 2D SE imaging and 3D MP-RAGE transverse imaging. Four radiologists interpreted the images to compare the accuracy and the time required for interpretation for each imaging. Results: 3D MP-RAGE imaging was significantly better than 2D SE imaging for detecting metastatic brain lesions, regardless of the readers' experience. The sensitivities of the 3D MP-RAGE and 2D SE imaging for all observers were 0.81 vs. 0.80 (P>0.05), specificities were 0.93 vs. 0.87 (P 0.05), and accuracies were 0.84 vs. 0.78 (P<0.05), respectively. There was no significant difference in the time required for image interpretation between the two modalities (15.6±4.0 vs. 15.4±4.1 min). Conclusion: 3D MP-RAGE imaging proved superior to 2D SE imaging in the detection of brain metastases

  3. A biomechanical modeling-guided simultaneous motion estimation and image reconstruction technique (SMEIR-Bio) for 4D-CBCT reconstruction

    Science.gov (United States)

    Huang, Xiaokun; Zhang, You; Wang, Jing

    2018-02-01

    Reconstructing four-dimensional cone-beam computed tomography (4D-CBCT) images directly from respiratory phase-sorted traditional 3D-CBCT projections can capture target motion trajectory, reduce motion artifacts, and reduce imaging dose and time. However, the limited numbers of projections in each phase after phase-sorting decreases CBCT image quality under traditional reconstruction techniques. To address this problem, we developed a simultaneous motion estimation and image reconstruction (SMEIR) algorithm, an iterative method that can reconstruct higher quality 4D-CBCT images from limited projections using an inter-phase intensity-driven motion model. However, the accuracy of the intensity-driven motion model is limited in regions with fine details whose quality is degraded due to insufficient projection number, which consequently degrades the reconstructed image quality in corresponding regions. In this study, we developed a new 4D-CBCT reconstruction algorithm by introducing biomechanical modeling into SMEIR (SMEIR-Bio) to boost the accuracy of the motion model in regions with small fine structures. The biomechanical modeling uses tetrahedral meshes to model organs of interest and solves internal organ motion using tissue elasticity parameters and mesh boundary conditions. This physics-driven approach enhances the accuracy of solved motion in the organ’s fine structures regions. This study used 11 lung patient cases to evaluate the performance of SMEIR-Bio, making both qualitative and quantitative comparisons between SMEIR-Bio, SMEIR, and the algebraic reconstruction technique with total variation regularization (ART-TV). The reconstruction results suggest that SMEIR-Bio improves the motion model’s accuracy in regions containing small fine details, which consequently enhances the accuracy and quality of the reconstructed 4D-CBCT images.

  4. D Reconstruction from Uav-Based Hyperspectral Images

    Science.gov (United States)

    Liu, L.; Xu, L.; Peng, J.

    2018-04-01

    Reconstructing the 3D profile from a set of UAV-based images can obtain hyperspectral information, as well as the 3D coordinate of any point on the profile. Our images are captured from the Cubert UHD185 (UHD) hyperspectral camera, which is a new type of high-speed onboard imaging spectrometer. And it can get both hyperspectral image and panchromatic image simultaneously. The panchromatic image have a higher spatial resolution than hyperspectral image, but each hyperspectral image provides considerable information on the spatial spectral distribution of the object. Thus there is an opportunity to derive a high quality 3D point cloud from panchromatic image and considerable spectral information from hyperspectral image. The purpose of this paper is to introduce our processing chain that derives a database which can provide hyperspectral information and 3D position of each point. First, We adopt a free and open-source software, Visual SFM which is based on structure from motion (SFM) algorithm, to recover 3D point cloud from panchromatic image. And then get spectral information of each point from hyperspectral image by a self-developed program written in MATLAB. The production can be used to support further research and applications.

  5. New and convenient synthesis of 2-deoxy-D-ribose from 2,4-O-ethylidene-D-erythrose

    Energy Technology Data Exchange (ETDEWEB)

    Hauske, J.R.; Rapoport, H.

    1979-01-01

    A new synthesis is described of 2-deoxy-D-erythro-pentose (2-deoxy-D-ribose,2-deoxy-D-arabinose (1)), starting from D-glucose. The synthesis proceeds through direct olefination of 2,4-O-ethylidene-D-erythrose (2) by addition of the stabilized ylides generated from dimethylphosphorylmethyl phenyl sulfide (4) and the corresponding sulfoxide 5. These afford the key intermediates, thio-enol ether 7 and ..cap alpha..,..beta..-unsaturated sulfoxide 8, which when subjected to mercuric ion assisted hydrolysis gave high yields of 2-deoxy-D-ribose (1). This facile chain extension of 2 required its existance as a monomer, and conditions effective for obtaining the monomer have been developed. Detailed /sup 1/H and /sup 13/C NMR studies of these compounds are presented.

  6. Box-Counting Method of 2D Neuronal Image: Method Modification and Quantitative Analysis Demonstrated on Images from the Monkey and Human Brain

    Directory of Open Access Journals (Sweden)

    Nemanja Rajković

    2017-01-01

    Full Text Available This study calls attention to the difference between traditional box-counting method and its modification. The appropriate scaling factor, influence on image size and resolution, and image rotation, as well as different image presentation, are showed on the sample of asymmetrical neurons from the monkey dentate nucleus. The standard BC method and its modification were evaluated on the sample of 2D neuronal images from the human neostriatum. In addition, three box dimensions (which estimate the space-filling property, the shape, complexity, and the irregularity of dendritic tree were used to evaluate differences in the morphology of type III aspiny neurons between two parts of the neostriatum.

  7. Box-Counting Method of 2D Neuronal Image: Method Modification and Quantitative Analysis Demonstrated on Images from the Monkey and Human Brain.

    Science.gov (United States)

    Rajković, Nemanja; Krstonošić, Bojana; Milošević, Nebojša

    2017-01-01

    This study calls attention to the difference between traditional box-counting method and its modification. The appropriate scaling factor, influence on image size and resolution, and image rotation, as well as different image presentation, are showed on the sample of asymmetrical neurons from the monkey dentate nucleus. The standard BC method and its modification were evaluated on the sample of 2D neuronal images from the human neostriatum. In addition, three box dimensions (which estimate the space-filling property, the shape, complexity, and the irregularity of dendritic tree) were used to evaluate differences in the morphology of type III aspiny neurons between two parts of the neostriatum.

  8. Contrast-enhanced MR imaging of metastatic brain tumor at 3 Tesla. Utility of T1-weighted SPACE compared with 2D spin echo and 3D gradient echo sequence

    International Nuclear Information System (INIS)

    Komada, Tomohiro; Naganawa, Shinji; Ogawa, Hiroshi

    2008-01-01

    We evaluated the newly developed whole-brain, isotropic, 3-dimensional turbo spin-echo imaging with variable flip angle echo train (SPACE) for contrast-enhanced T 1 -weighted imaging in detecting brain metastases at 3 tesla (T). Twenty-two patients with suspected brain metastases underwent postcontrast study with SPACE, magnetization-prepared rapid gradient-echo (MP-RAGE), and 2-dimensional T 1 -weighted spin echo (2D-SE) imaging at 3 T. We quantitatively compared SPACE, MP-RAGE, and 2D-SE images by using signal-to-noise ratios (SNRs) for gray matter (GM) and white matter (WM) and contrast-to-noise ratios (CNRs) for GM-to-WM, lesion-to-GM, and lesion-to-WM. Two blinded radiologists evaluated the detection of brain metastases by segment-by-segment analysis and continuously-distributed test. The CNR between GM and WM was significantly higher on MP-RAGE images than on SPACE images (P 1 -weighted imaging. (author)

  9. Dual optimization based prostate zonal segmentation in 3D MR images.

    Science.gov (United States)

    Qiu, Wu; Yuan, Jing; Ukwatta, Eranga; Sun, Yue; Rajchl, Martin; Fenster, Aaron

    2014-05-01

    Efficient and accurate segmentation of the prostate and two of its clinically meaningful sub-regions: the central gland (CG) and peripheral zone (PZ), from 3D MR images, is of great interest in image-guided prostate interventions and diagnosis of prostate cancer. In this work, a novel multi-region segmentation approach is proposed to simultaneously segment the prostate and its two major sub-regions from only a single 3D T2-weighted (T2w) MR image, which makes use of the prior spatial region consistency and incorporates a customized prostate appearance model into the segmentation task. The formulated challenging combinatorial optimization problem is solved by means of convex relaxation, for which a novel spatially continuous max-flow model is introduced as the dual optimization formulation to the studied convex relaxed optimization problem with region consistency constraints. The proposed continuous max-flow model derives an efficient duality-based algorithm that enjoys numerical advantages and can be easily implemented on GPUs. The proposed approach was validated using 18 3D prostate T2w MR images with a body-coil and 25 images with an endo-rectal coil. Experimental results demonstrate that the proposed method is capable of efficiently and accurately extracting both the prostate zones: CG and PZ, and the whole prostate gland from the input 3D prostate MR images, with a mean Dice similarity coefficient (DSC) of 89.3±3.2% for the whole gland (WG), 82.2±3.0% for the CG, and 69.1±6.9% for the PZ in 3D body-coil MR images; 89.2±3.3% for the WG, 83.0±2.4% for the CG, and 70.0±6.5% for the PZ in 3D endo-rectal coil MR images. In addition, the experiments of intra- and inter-observer variability introduced by user initialization indicate a good reproducibility of the proposed approach in terms of volume difference (VD) and coefficient-of-variation (CV) of DSC. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. 2D-3D rigid registration to compensate for prostate motion during 3D TRUS-guided biopsy.

    Science.gov (United States)

    De Silva, Tharindu; Fenster, Aaron; Cool, Derek W; Gardi, Lori; Romagnoli, Cesare; Samarabandu, Jagath; Ward, Aaron D

    2013-02-01

    Three-dimensional (3D) transrectal ultrasound (TRUS)-guided systems have been developed to improve targeting accuracy during prostate biopsy. However, prostate motion during the procedure is a potential source of error that can cause target misalignments. The authors present an image-based registration technique to compensate for prostate motion by registering the live two-dimensional (2D) TRUS images acquired during the biopsy procedure to a preacquired 3D TRUS image. The registration must be performed both accurately and quickly in order to be useful during the clinical procedure. The authors implemented an intensity-based 2D-3D rigid registration algorithm optimizing the normalized cross-correlation (NCC) metric using Powell's method. The 2D TRUS images acquired during the procedure prior to biopsy gun firing were registered to the baseline 3D TRUS image acquired at the beginning of the procedure. The accuracy was measured by calculating the target registration error (TRE) using manually identified fiducials within the prostate; these fiducials were used for validation only and were not provided as inputs to the registration algorithm. They also evaluated the accuracy when the registrations were performed continuously throughout the biopsy by acquiring and registering live 2D TRUS images every second. This measured the improvement in accuracy resulting from performing the registration, continuously compensating for motion during the procedure. To further validate the method using a more challenging data set, registrations were performed using 3D TRUS images acquired by intentionally exerting different levels of ultrasound probe pressures in order to measure the performance of our algorithm when the prostate tissue was intentionally deformed. In this data set, biopsy scenarios were simulated by extracting 2D frames from the 3D TRUS images and registering them to the baseline 3D image. A graphics processing unit (GPU)-based implementation was used to improve the

  11. Leaf Area Index Estimation in Vineyards from Uav Hyperspectral Data, 2d Image Mosaics and 3d Canopy Surface Models

    Science.gov (United States)

    Kalisperakis, I.; Stentoumis, Ch.; Grammatikopoulos, L.; Karantzalos, K.

    2015-08-01

    The indirect estimation of leaf area index (LAI) in large spatial scales is crucial for several environmental and agricultural applications. To this end, in this paper, we compare and evaluate LAI estimation in vineyards from different UAV imaging datasets. In particular, canopy levels were estimated from i.e., (i) hyperspectral data, (ii) 2D RGB orthophotomosaics and (iii) 3D crop surface models. The computed canopy levels have been used to establish relationships with the measured LAI (ground truth) from several vines in Nemea, Greece. The overall evaluation indicated that the estimated canopy levels were correlated (r2 > 73%) with the in-situ, ground truth LAI measurements. As expected the lowest correlations were derived from the calculated greenness levels from the 2D RGB orthomosaics. The highest correlation rates were established with the hyperspectral canopy greenness and the 3D canopy surface models. For the later the accurate detection of canopy, soil and other materials in between the vine rows is required. All approaches tend to overestimate LAI in cases with sparse, weak, unhealthy plants and canopy.

  12. Interpretation of mandibular condyle fractures using 2D- and 3D-computed tomography

    Directory of Open Access Journals (Sweden)

    Costa e Silva Adriana Paula de Andrade da

    2003-01-01

    Full Text Available Computed tomography (CT has been increasingly used in the examination of patients with craniofacial trauma. This technique is useful in the examination of the temporomandibular joint and allows the diagnosis of fractures of the mandibular condyle. Aiming to verify whether the three-dimensional reconstructed images from CT (3D-CT produce more effective visual information than the two-dimensional (2D-CT ones, we evaluated 2D-CT and 3D-CT examinations of 18 patients with mandibular condyle fractures. We observed that 2D-CT and 3D-CT reconstructed images produced similar information for the diagnosis of fractures of the mandibular condyle, although the 3D-CT allowed a better visualization of the position and displacement of bone fragments, as well as the comminution of fractures. These results, together with the possibility of refining and manipulating perspectives in 3D images, reinforce the importance of its use in the surgical planning and evaluation of treatment. We concluded that 3D-CT presented supplementary information for a more effective diagnosis of mandibular condyle fractures.

  13. Digital Image Correlation of 2D X-ray Powder Diffraction Data for Lattice Strain Evaluation

    Science.gov (United States)

    Zhang, Hongjia; Sui, Tan; Daisenberger, Dominik; Fong, Kai Soon

    2018-01-01

    High energy 2D X-ray powder diffraction experiments are widely used for lattice strain measurement. The 2D to 1D conversion of diffraction patterns is a necessary step used to prepare the data for full pattern refinement, but is inefficient when only peak centre position information is required for lattice strain evaluation. The multi-step conversion process is likely to lead to increased errors associated with the ‘caking’ (radial binning) or fitting procedures. A new method is proposed here that relies on direct Digital Image Correlation analysis of 2D X-ray powder diffraction patterns (XRD-DIC, for short). As an example of using XRD-DIC, residual strain values along the central line in a Mg AZ31B alloy bar after 3-point bending are calculated by using both XRD-DIC and the conventional ‘caking’ with fitting procedures. Comparison of the results for strain values in different azimuthal angles demonstrates excellent agreement between the two methods. The principal strains and directions are calculated using multiple direction strain data, leading to full in-plane strain evaluation. It is therefore concluded that XRD-DIC provides a reliable and robust method for strain evaluation from 2D powder diffraction data. The XRD-DIC approach simplifies the analysis process by skipping 2D to 1D conversion, and opens new possibilities for robust 2D powder diffraction data analysis for full in-plane strain evaluation. PMID:29543728

  14. Digital Image Correlation of 2D X-ray Powder Diffraction Data for Lattice Strain Evaluation

    Directory of Open Access Journals (Sweden)

    Hongjia Zhang

    2018-03-01

    Full Text Available High energy 2D X-ray powder diffraction experiments are widely used for lattice strain measurement. The 2D to 1D conversion of diffraction patterns is a necessary step used to prepare the data for full pattern refinement, but is inefficient when only peak centre position information is required for lattice strain evaluation. The multi-step conversion process is likely to lead to increased errors associated with the ‘caking’ (radial binning or fitting procedures. A new method is proposed here that relies on direct Digital Image Correlation analysis of 2D X-ray powder diffraction patterns (XRD-DIC, for short. As an example of using XRD-DIC, residual strain values along the central line in a Mg AZ31B alloy bar after 3-point bending are calculated by using both XRD-DIC and the conventional ‘caking’ with fitting procedures. Comparison of the results for strain values in different azimuthal angles demonstrates excellent agreement between the two methods. The principal strains and directions are calculated using multiple direction strain data, leading to full in-plane strain evaluation. It is therefore concluded that XRD-DIC provides a reliable and robust method for strain evaluation from 2D powder diffraction data. The XRD-DIC approach simplifies the analysis process by skipping 2D to 1D conversion, and opens new possibilities for robust 2D powder diffraction data analysis for full in-plane strain evaluation.

  15. 3D images and expert system

    International Nuclear Information System (INIS)

    Hasegawa, Jun-ichi

    1998-01-01

    This paper presents an expert system called 3D-IMPRESS for supporting applications of three dimensional (3D) image processing. This system can automatically construct a 3D image processing procedure based on a pictorial example of the goal given by a user. In the paper, to evaluate the performance of the system, it was applied to construction of procedures for extracting specific component figures from practical chest X-ray CT images. (author)

  16. Fat suppression at 2D MR imaging of the hands: Dixon method versus CHESS technique and STIR sequence.

    Science.gov (United States)

    Kirchgesner, Thomas; Perlepe, Vasiliki; Michoux, Nicolas; Larbi, Ahmed; Vande Berg, Bruno

    2017-04-01

    To compare the effectiveness of fat suppression and the signal-to-noise ratio (SNR) of the Dixon method with those of the CHESS (Chemical Shift-Selective) technique and STIR (Short Tau Inversion Recovery) sequence in hands of normal subjects at 2D MR imaging. 14 healthy volunteers (mean age of 29.4 years) consented to have both hands prospectively imaged with SE T1 Dixon, T1 CHESS, T2 Dixon, T2 CHESS and STIR sequences in a 1.5T MR scanner. Three radiologists scored the effectiveness of fat suppression in bone marrow (EFS BM ) and soft tissues (EFS ST ) in 20 joints per subject. One radiologist measured the SNR in 10 bones per subject. Statistical analysis used two-way ANOVA with random effects, paired t-test and observed agreement to assess differences in effectiveness of fat suppression, differences in SNR and inter-observer agreement. EFS BM was statistically significantly higher for T1 Dixon than for T1 CHESS and for T2 Dixon than for T2 CHESS (pCHESS and for T2 Dixon than for STIR (pCHESS (pCHESS technique at 2D T1-weighted MR imaging of the hands. At T2-weighted MR imaging, fat suppression is more effective with the Dixon method while SNR is higher with the CHESS technique. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. D3D augmented reality imaging system: proof of concept in mammography.

    Science.gov (United States)

    Douglas, David B; Petricoin, Emanuel F; Liotta, Lance; Wilson, Eugene

    2016-01-01

    The purpose of this article is to present images from simulated breast microcalcifications and assess the pattern of the microcalcifications with a technical development called "depth 3-dimensional (D3D) augmented reality". A computer, head display unit, joystick, D3D augmented reality software, and an in-house script of simulated data of breast microcalcifications in a ductal distribution were used. No patient data was used and no statistical analysis was performed. The D3D augmented reality system demonstrated stereoscopic depth perception by presenting a unique image to each eye, focal point convergence, head position tracking, 3D cursor, and joystick fly-through. The D3D augmented reality imaging system offers image viewing with depth perception and focal point convergence. The D3D augmented reality system should be tested to determine its utility in clinical practice.

  18. GPU-accelerated Kernel Regression Reconstruction for Freehand 3D Ultrasound Imaging.

    Science.gov (United States)

    Wen, Tiexiang; Li, Ling; Zhu, Qingsong; Qin, Wenjian; Gu, Jia; Yang, Feng; Xie, Yaoqin

    2017-07-01

    Volume reconstruction method plays an important role in improving reconstructed volumetric image quality for freehand three-dimensional (3D) ultrasound imaging. By utilizing the capability of programmable graphics processing unit (GPU), we can achieve a real-time incremental volume reconstruction at a speed of 25-50 frames per second (fps). After incremental reconstruction and visualization, hole-filling is performed on GPU to fill remaining empty voxels. However, traditional pixel nearest neighbor-based hole-filling fails to reconstruct volume with high image quality. On the contrary, the kernel regression provides an accurate volume reconstruction method for 3D ultrasound imaging but with the cost of heavy computational complexity. In this paper, a GPU-based fast kernel regression method is proposed for high-quality volume after the incremental reconstruction of freehand ultrasound. The experimental results show that improved image quality for speckle reduction and details preservation can be obtained with the parameter setting of kernel window size of [Formula: see text] and kernel bandwidth of 1.0. The computational performance of the proposed GPU-based method can be over 200 times faster than that on central processing unit (CPU), and the volume with size of 50 million voxels in our experiment can be reconstructed within 10 seconds.

  19. Three-dimensional imaging of Drosophila melanogaster.

    Directory of Open Access Journals (Sweden)

    Leeanne McGurk

    2007-09-01

    Full Text Available The major hindrance to imaging the intact adult Drosophila is that the dark exoskeleton makes it impossible to image through the cuticle. We have overcome this obstacle and describe a method whereby the internal organs of adult Drosophila can be imaged in 3D by bleaching and clearing the adult and then imaging using a technique called optical projection tomography (OPT. The data is displayed as 2D optical sections and also in 3D to provide detail on the shape and structure of the adult anatomy.We have used OPT to visualize in 2D and 3D the detailed internal anatomy of the intact adult Drosophila. In addition this clearing method used for OPT was tested for imaging with confocal microscopy. Using OPT we have visualized the size and shape of neurodegenerative vacuoles from within the head capsule of flies that suffer from age-related neurodegeneration due to a lack of ADAR mediated RNA-editing. In addition we have visualized tau-lacZ expression in 2D and 3D. This shows that the wholemount adult can be stained without any manipulation and that this stain penetrates well as we have mapped the localization pattern with respect to the internal anatomy.We show for the first time that the intact adult Drosophila can be imaged in 3D using OPT, also we show that this method of clearing is also suitable for confocal microscopy to image the brain from within the intact head. The major advantage of this is that organs can be represented in 3D in their natural surroundings. Furthermore optical sections are generated in each of the three planes and are not prone to the technical limitations that are associated with manual sectioning. OPT can be used to dissect mutant phenotypes and to globally map gene expression in both 2D and 3D.

  20. Subsurface Profile Mapping using 3-D Compressive Wave Imaging

    Directory of Open Access Journals (Sweden)

    Hazreek Z A M

    2017-01-01

    Full Text Available Geotechnical site investigation related to subsurface profile mapping was commonly performed to provide valuable data for design and construction stage based on conventional drilling techniques. From past experience, drilling techniques particularly using borehole method suffer from limitations related to expensive, time consuming and limited data coverage. Hence, this study performs subsurface profile mapping using 3-D compressive wave imaging in order to minimize those conventional method constraints. Field measurement and data analysis of compressive wave (p-wave, vp was performed using seismic refraction survey (ABEM Terraloc MK 8, 7 kg of sledgehammer and 24 units of vertical geophone and OPTIM (SeisOpt@Picker & SeisOpt@2D software respectively. Then, 3-D compressive wave distribution of subsurface studied was obtained using analysis of SURFER software. Based on 3-D compressive wave image analyzed, it was found that subsurface profile studied consist of three main layers representing top soil (vp = 376 – 600 m/s, weathered material (vp = 900 – 2600 m/s and bedrock (vp > 3000 m/s. Thickness of each layer was varied from 0 – 2 m (first layer, 2 – 20 m (second layer and 20 m and over (third layer. Moreover, groundwater (vp = 1400 – 1600 m/s starts to be detected at 2.0 m depth from ground surface. This study has demonstrated that geotechnical site investigation data related to subsurface profiling was applicable to be obtained using 3-D compressive wave imaging. Furthermore, 3-D compressive wave imaging was performed based on non destructive principle in ground exploration thus consider economic, less time, large data coverage and sustainable to our environment.

  1. A statistical shape modelling framework to extract 3D shape biomarkers from medical imaging data: assessing arch morphology of repaired coarctation of the aorta

    International Nuclear Information System (INIS)

    Bruse, Jan L.; McLeod, Kristin; Biglino, Giovanni; Ntsinjana, Hopewell N.; Capelli, Claudio

    2016-01-01

    Medical image analysis in clinical practice is commonly carried out on 2D image data, without fully exploiting the detailed 3D anatomical information that is provided by modern non-invasive medical imaging techniques. In this paper, a statistical shape analysis method is presented, which enables the extraction of 3D anatomical shape features from cardiovascular magnetic resonance (CMR) image data, with no need for manual landmarking. The method was applied to repaired aortic coarctation arches that present complex shapes, with the aim of capturing shape features as biomarkers of potential functional relevance. The method is presented from the user-perspective and is evaluated by comparing results with traditional morphometric measurements. Steps required to set up the statistical shape modelling analyses, from pre-processing of the CMR images to parameter setting and strategies to account for size differences and outliers, are described in detail. The anatomical mean shape of 20 aortic arches post-aortic coarctation repair (CoA) was computed based on surface models reconstructed from CMR data. By analysing transformations that deform the mean shape towards each of the individual patient’s anatomy, shape patterns related to differences in body surface area (BSA) and ejection fraction (EF) were extracted. The resulting shape vectors, describing shape features in 3D, were compared with traditionally measured 2D and 3D morphometric parameters. The computed 3D mean shape was close to population mean values of geometric shape descriptors and visually integrated characteristic shape features associated with our population of CoA shapes. After removing size effects due to differences in body surface area (BSA) between patients, distinct 3D shape features of the aortic arch correlated significantly with EF (r = 0.521, p = .022) and were well in agreement with trends as shown by traditional shape descriptors. The suggested method has the potential to discover previously

  2. MapX: 2D XRF for Planetary Exploration - Image Formation and Optic Characterization

    Science.gov (United States)

    Sarrazin, P.; Blake, D.; Gailhanou, M.; Marchis, F.; Chalumeau, C.; Webb, S.; Walter, P.; Schyns, E.; Thompson, K.; Bristow, T.

    2018-04-01

    Map-X is a planetary instrument concept for 2D X-Ray Fluorescence (XRF) spectroscopy. The instrument is placed directly on the surface of an object and held in a fixed position during the measurement. The formation of XRF images on the CCD detector relies on a multichannel optic configured for 1:1 imaging and can be analyzed through the point spread function (PSF) of the optic. The PSF can be directly measured using a micron-sized monochromatic X-ray source in place of the sample. Such PSF measurements were carried out at the Stanford Synchrotron and are compared with ray tracing simulations. It is shown that artifacts are introduced by the periodicity of the PSF at the channel scale and the proximity of the CCD pixel size and the optic channel size. A strategy of sub-channel random moves was used to cancel out these artifacts and provide a clean experimental PSF directly usable for XRF image deconvolution.

  3. SUV navigator enables rapid [18F]-FDG PET/CT image interpretation compared with 2D ROI and 3D VOI evaluations

    International Nuclear Information System (INIS)

    Okizaki, Atsutaka; Nakayama Michihiro; Ishitoya, Shunta; Nakajima, Kaori; Yamashina Masaaki; Aburano, Tamio; Takahashi, Koji

    2017-01-01

    Positron emission tomography (PET) and the maximum standardized uptake value (SUV max ) is a useful technique for assessing malignant tumors. Measurements of SUV max in multiple lesions per patient frequently require many time-consuming procedures. To address this issue, we designed a novel interface named SUV Navigator (SUVnavi), and the purpose of this study was to investigate its utility. We measured SUV max in 661 lesions from 100 patients with malignant tumors. Diagnoses and SUV max measurements were made with SUVnavi, 2D, and 3D measurements. SUV measurement accuracy in each method were also evaluated. The average reduction in time with SUVnavi versus 2D was 53.8% and 3D was 37.5%; time required with SUVnavi was significantly shorter than with 2D and 3D (P < 0.001 and P < 0.001, respectively). The time reduction and lesion number had a positive correlation (P < 0.001 and P < 0.001, respectively). SUV max agreed with precise SUV max in all lesions measured with SUVnavi and 3D but in only 466 of 661 lesions (70.5%) measured with 2D. Conclusion SUVnavi may be useful for rapid [ 18 F]-fluorodeoxyglucose positron emission tomogra phy/computed tomography ([ 18 F]-FDG PET/CT) image interpretation without reducing the accuracy of SUV max measurement. (author)

  4. Feature-Based Retinal Image Registration Using D-Saddle Feature

    Directory of Open Access Journals (Sweden)

    Roziana Ramli

    2017-01-01

    Full Text Available Retinal image registration is important to assist diagnosis and monitor retinal diseases, such as diabetic retinopathy and glaucoma. However, registering retinal images for various registration applications requires the detection and distribution of feature points on the low-quality region that consists of vessels of varying contrast and sizes. A recent feature detector known as Saddle detects feature points on vessels that are poorly distributed and densely positioned on strong contrast vessels. Therefore, we propose a multiresolution difference of Gaussian pyramid with Saddle detector (D-Saddle to detect feature points on the low-quality region that consists of vessels with varying contrast and sizes. D-Saddle is tested on Fundus Image Registration (FIRE Dataset that consists of 134 retinal image pairs. Experimental results show that D-Saddle successfully registered 43% of retinal image pairs with average registration accuracy of 2.329 pixels while a lower success rate is observed in other four state-of-the-art retinal image registration methods GDB-ICP (28%, Harris-PIIFD (4%, H-M (16%, and Saddle (16%. Furthermore, the registration accuracy of D-Saddle has the weakest correlation (Spearman with the intensity uniformity metric among all methods. Finally, the paired t-test shows that D-Saddle significantly improved the overall registration accuracy of the original Saddle.

  5. TU-C-BRD-01: Image Guided SBRT I: Multi-Modality 4D Imaging

    International Nuclear Information System (INIS)

    Cai, J; Mageras, G; Pan, T

    2014-01-01

    Motion management is one of the critical technical challenges for radiation therapy. 4D imaging has been rapidly adopted as essential tool to assess organ motion associated with respiratory breathing. A variety of 4D imaging techniques have been developed and are currently under development based on different imaging modalities such as CT, MRI, PET, and CBCT. Each modality provides specific and complementary information about organ and tumor respiratory motion. Effective use of each different technique or combined use of different techniques can introduce a comprehensive management of tumor motion. Specifically, these techniques have afforded tremendous opportunities to better define and delineate tumor volumes, more accurately perform patient positioning, and effectively apply highly conformal therapy techniques such as IMRT and SBRT. Successful implementation requires good understanding of not only each technique, including unique features, limitations, artifacts, imaging acquisition and process, but also how to systematically apply the information obtained from different imaging modalities using proper tools such as deformable image registration. Furthermore, it is important to understand the differences in the effects of breathing variation between different imaging modalities. A comprehensive motion management strategy using multi-modality 4D imaging has shown promise in improving patient care, but at the same time faces significant challenges. This session will focuses on the current status and advances in imaging respiration-induced organ motion with different imaging modalities: 4D-CT, 4D-MRI, 4D-PET, and 4D-CBCT/DTS. Learning Objectives: Understand the need and role of multimodality 4D imaging in radiation therapy. Understand the underlying physics behind each 4D imaging technique. Recognize the advantages and limitations of each 4D imaging technique

  6. Multiscale image contrast amplification (MUSICA)

    Science.gov (United States)

    Vuylsteke, Pieter; Schoeters, Emile P.

    1994-05-01

    This article presents a novel approach to the problem of detail contrast enhancement, based on multiresolution representation of the original image. The image is decomposed into a weighted sum of smooth, localized, 2D basis functions at multiple scales. Each transform coefficient represents the amount of local detail at some specific scale and at a specific position in the image. Detail contrast is enhanced by non-linear amplification of the transform coefficients. An inverse transform is then applied to the modified coefficients. This yields a uniformly contrast- enhanced image without artefacts. The MUSICA-algorithm is being applied routinely to computed radiography images of chest, skull, spine, shoulder, pelvis, extremities, and abdomen examinations, with excellent acceptance. It is useful for a wide range of applications in the medical, graphical, and industrial area.

  7. Acute Cocaine Induces Fast Activation of D1 Receptor and Progressive Deactivation of D2 Receptor Strial Neurons: In Vivo Optical Microprobe [Ca(superscript)2+]subscript)i Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Du, C.; Luo, Z.; Volkow, N.D.; Heintz, N.; Pan, Y.; Du, C.

    2011-09-14

    Cocaine induces fast dopamine increases in brain striatal regions, which are recognized to underlie its rewarding effects. Both dopamine D1 and D2 receptors are involved in cocaine's reward but the dynamic downstream consequences of cocaine effects in striatum are not fully understood. Here we used transgenic mice expressing EGFP under the control of either the D1 receptor (D1R) or the D2 receptor (D2R) gene and microprobe optical imaging to assess the dynamic changes in intracellular calcium ([Ca{sup 2+}]{sub i} ) responses (used as marker of neuronal activation) to acute cocaine in vivo separately for D1R- versus D2R-expressing neurons in striatum. Acute cocaine (8 mg/kg, i.p.) rapidly increased [Ca{sup 2+}]{sub i} in D1R-expressing neurons (10.6 {+-} 3.2%) in striatum within 8.3 {+-} 2.3 min after cocaine administration after which the increases plateaued; these fast [Ca{sup 2+}]{sub i} increases were blocked by pretreatment with a D1R antagonist (SCH23390). In contrast, cocaine induced progressive decreases in [Ca{sup 2+}]{sub i} in D2R-expressing neurons (10.4 {+-} 5.8%) continuously throughout the 30 min that followed cocaine administration; these slower [Ca{sup 2+}]{sub i} decreases were blocked by pretreatment with a D2R antagonist (raclopride). Since activation of striatal D1R-expressing neurons (direct-pathway) enhances cocaine reward, whereas activation of D2R expressing neurons suppresses it (indirect-pathway) (Lobo et al., 2010), this suggests that cocaine's rewarding effects entail both its fast stimulation ofD1R (resulting in abrupt activation of direct-pathway neurons) and a slower stimulation of D2R (resulting in longer-lasting deactivation of indirect-pathway neurons). We also provide direct in vivo evidence of D2R and D1R interactions in the striatal responses to acute cocaine administration.

  8. A comparison of porosity analysis using 2D stereology estimates and 3D serial sectioning for additively manufactured Ti 6Al 2Sn 4Zr 2Mo alloy; Vergleich der Porositaetsanalyse einer Ti 6Al 2Sn 4Zr 2Mo-Legierung aus additiver Fertigung mittels stereologischer Schaetzungen (2D) und mit Serienschnitten (3D)

    Energy Technology Data Exchange (ETDEWEB)

    Ganti, Satya R.; Velez, Michael A.; Geier, Brian A.; Hayes, Brian J.; Turner, Bryan J.; Jenkins, Elizabeth J. [UES Inc., Dayton, OH (United States)

    2017-02-15

    Porosity is a typical defect in additively manufactured (AM) parts. Such defects limit the properties and performance of AM parts, and therefore need to be characterized accurately. Current methods for characterization of defects and microstructure rely on classical stereological methods that extrapolate information from two dimensional images. The automation of serial sectioning provides an opportunity to precisely and accurately quantify porosity in three dimensions in materials. In this work, we analyzed the porosity of an additively manufactured Ti 6Al 2Sn 4Zr 2Mo sample using Robo-Met.3D {sup registered}, an automated serial sectioning system. Image processing for three dimensional reconstruction of the serial-sectioned two dimensional images was performed using open source image analysis software (Fiji/ImageJ, Dream.3D, Paraview). The results from this 3D serial sectioning analysis were then compared to classical 2D stereological methods (Saltykov stereological theory). We found that for this dataset, the classical 2D methods underestimated the porosity size and distributions of the larger pores; a critical attribute to fatigue behavior of the AM part. The results suggest that acquiring experimental data with equipment such as Robo-Met.3D {sup registered} to measure the number and size of particles such as pores in a volume irrespective of knowing their shape is a better choice.

  9. 3D-SIFT-Flow for atlas-based CT liver image segmentation.

    Science.gov (United States)

    Xu, Yan; Xu, Chenchao; Kuang, Xiao; Wang, Hongkai; Chang, Eric I-Chao; Huang, Weimin; Fan, Yubo

    2016-05-01

    In this paper, the authors proposed a new 3D registration algorithm, 3D-scale invariant feature transform (SIFT)-Flow, for multiatlas-based liver segmentation in computed tomography (CT) images. In the registration work, the authors developed a new registration method that takes advantage of dense correspondence using the informative and robust SIFT feature. The authors computed the dense SIFT features for the source image and the target image and designed an objective function to obtain the correspondence between these two images. Labeling of the source image was then mapped to the target image according to the former correspondence, resulting in accurate segmentation. In the fusion work, the 2D-based nonparametric label transfer method was extended to 3D for fusing the registered 3D atlases. Compared with existing registration algorithms, 3D-SIFT-Flow has its particular advantage in matching anatomical structures (such as the liver) that observe large variation/deformation. The authors observed consistent improvement over widely adopted state-of-the-art registration methods such as ELASTIX, ANTS, and multiatlas fusion methods such as joint label fusion. Experimental results of liver segmentation on the MICCAI 2007 Grand Challenge are encouraging, e.g., Dice overlap ratio 96.27% ± 0.96% by our method compared with the previous state-of-the-art result of 94.90% ± 2.86%. Experimental results show that 3D-SIFT-Flow is robust for segmenting the liver from CT images, which has large tissue deformation and blurry boundary, and 3D label transfer is effective and efficient for improving the registration accuracy.

  10. AUTOMATED CELL SEGMENTATION WITH 3D FLUORESCENCE MICROSCOPY IMAGES.

    Science.gov (United States)

    Kong, Jun; Wang, Fusheng; Teodoro, George; Liang, Yanhui; Zhu, Yangyang; Tucker-Burden, Carol; Brat, Daniel J

    2015-04-01

    A large number of cell-oriented cancer investigations require an effective and reliable cell segmentation method on three dimensional (3D) fluorescence microscopic images for quantitative analysis of cell biological properties. In this paper, we present a fully automated cell segmentation method that can detect cells from 3D fluorescence microscopic images. Enlightened by fluorescence imaging techniques, we regulated the image gradient field by gradient vector flow (GVF) with interpolated and smoothed data volume, and grouped voxels based on gradient modes identified by tracking GVF field. Adaptive thresholding was then applied to voxels associated with the same gradient mode where voxel intensities were enhanced by a multiscale cell filter. We applied the method to a large volume of 3D fluorescence imaging data of human brain tumor cells with (1) small cell false detection and missing rates for individual cells; and (2) trivial over and under segmentation incidences for clustered cells. Additionally, the concordance of cell morphometry structure between automated and manual segmentation was encouraging. These results suggest a promising 3D cell segmentation method applicable to cancer studies.

  11. Extending Ripley's K-Function to Quantify Aggregation in 2-D Grayscale Images.

    Directory of Open Access Journals (Sweden)

    Mohamed Amgad

    Full Text Available In this work, we describe the extension of Ripley's K-function to allow for overlapping events at very high event densities. We show that problematic edge effects introduce significant bias to the function at very high densities and small radii, and propose a simple correction method that successfully restores the function's centralization. Using simulations of homogeneous Poisson distributions of events, as well as simulations of event clustering under different conditions, we investigate various aspects of the function, including its shape-dependence and correspondence between true cluster radius and radius at which the K-function is maximized. Furthermore, we validate the utility of the function in quantifying clustering in 2-D grayscale images using three modalities: (i Simulations of particle clustering; (ii Experimental co-expression of soluble and diffuse protein at varying ratios; (iii Quantifying chromatin clustering in the nuclei of wt and crwn1 crwn2 mutant Arabidopsis plant cells, using a previously-published image dataset. Overall, our work shows that Ripley's K-function is a valid abstract statistical measure whose utility extends beyond the quantification of clustering of non-overlapping events. Potential benefits of this work include the quantification of protein and chromatin aggregation in fluorescent microscopic images. Furthermore, this function has the potential to become one of various abstract texture descriptors that are utilized in computer-assisted diagnostics in anatomic pathology and diagnostic radiology.

  12. Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI

    Science.gov (United States)

    Stoebe, Stephan; Metze, Michael; Jurisch, Daniel; Tayal, Bhupendar; Solty, Kilian; Laufs, Ulrich; Pfeiffer, Dietrich; Hagendorff, Andreas

    2018-01-01

    Purpose The study compares the feasibility of the quantitative volumetric and semi-quantitative approach for quantification of chronic aortic regurgitation (AR) using different imaging modalities. Methods Left ventricular (LV) volumes, regurgitant volumes (RVol) and regurgitant fractions (RF) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-quantitative parameters were assessed by 2D echocardiography. Results 22 (40%) patients had mild, 25 (46%) moderate and 8 (14%) severe AR. The quantitative volumetric approach was feasible using 2D, 3D echocardiography and cMRI, whereas the feasibility of semi-quantitative parameters varied considerably. LV volume (LVEDV, LVESV, SVtot) analyses showed good correlations between the different imaging modalities, although significantly increased LV volumes were assessed by cMRI. RVol was significantly different between 2D/3D echocardiography and 2D echocardiography/cMRI but was not significantly different between 3D echocardiography/cMRI. RF was not statistically different between 2D echocardiography/cMRI and 3D echocardiography/cMRI showing poor correlations (r echocardiography and 2D echocardiography/cMRI and good agreement was observed between 3D echocardiography/cMRI. Conclusion Semi-quantitative parameters are difficult to determine by 2D echocardiography in clinical routine. The quantitative volumetric RF assessment seems to be feasible and can be discussed as an alternative approach in chronic AR. However, RVol and RF did not correlate well between the different imaging modalities. The best agreement for grading of AR severity by RF was observed between 3D echocardiography and cMRI. LV volumes can be verified by different approaches and different imaging modalities. PMID:29519957

  13. 3D fingerprint imaging system based on full-field fringe projection profilometry

    Science.gov (United States)

    Huang, Shujun; Zhang, Zonghua; Zhao, Yan; Dai, Jie; Chen, Chao; Xu, Yongjia; Zhang, E.; Xie, Lili

    2014-01-01

    As an unique, unchangeable and easily acquired biometrics, fingerprint has been widely studied in academics and applied in many fields over the years. The traditional fingerprint recognition methods are based on the obtained 2D feature of fingerprint. However, fingerprint is a 3D biological characteristic. The mapping from 3D to 2D loses 1D information and causes nonlinear distortion of the captured fingerprint. Therefore, it is becoming more and more important to obtain 3D fingerprint information for recognition. In this paper, a novel 3D fingerprint imaging system is presented based on fringe projection technique to obtain 3D features and the corresponding color texture information. A series of color sinusoidal fringe patterns with optimum three-fringe numbers are projected onto a finger surface. From another viewpoint, the fringe patterns are deformed by the finger surface and captured by a CCD camera. 3D shape data of the finger can be obtained from the captured fringe pattern images. This paper studies the prototype of the 3D fingerprint imaging system, including principle of 3D fingerprint acquisition, hardware design of the 3D imaging system, 3D calibration of the system, and software development. Some experiments are carried out by acquiring several 3D fingerprint data. The experimental results demonstrate the feasibility of the proposed 3D fingerprint imaging system.

  14. Common crus aplasia: diagnosis by 3D volume rendering imaging using 3DFT-CISS sequence

    International Nuclear Information System (INIS)

    Kim, H.J.; Song, J.W.; Chon, K.-M.; Goh, E.-K.

    2004-01-01

    AIM: The purpose of this study was to evaluate the findings of three-dimensional (3D) volume rendering (VR) imaging in common crus aplasia (CCA) of the inner ear. MATERIALS AND METHODS: Using 3D VR imaging of temporal bone constructive interference in steady state (CISS) magnetic resonance (MR) images, we retrospectively reviewed seven inner ears of six children who were candidates for cochlear implants and who had been diagnosed with CCA. As controls, we used the same method to examine 402 inner ears of 201 patients who had no clinical symptoms or signs of sensorineural hearing loss. Temporal bone MR imaging (MRI) was performed with a 1.5 T MR machine using a CISS sequence, and VR of the inner ear was performed on a work station. Morphological image analysis was performed on rotation views of 3D VR images. RESULTS: In all seven cases, CCA was diagnosed by the absence of the common crus. The remaining superior semicircular canal (SCC) was normal in five and hypoplastic in two inner ears, while the posterior SCC was normal in all seven. One patient showed bilateral symmetrical CCA. Complicated combined anomalies were seen in the cochlea, vestibule and lateral SCC. CONCLUSION: 3D VR imaging findings with MR CISS sequence can directly diagnose CCA. This technique may be useful in delineating detailed anomalies of SCCs

  15. Automatic measurement of cusps in 2.5D dental images

    Science.gov (United States)

    Wolf, Mattias; Paulus, Dietrich W.; Niemann, Heinrich

    1996-01-01

    Automatic reconstruction of occlusal surfaces of teeth is an application which might become more and more urgent due to the toxicity of amalgam. Modern dental chairside equipment is currently restricted to the production of inlays. The automatic reconstruction of the occlusal surface is presently not possible. For manufacturing an occlusal surface it is required to extract features from which it is possible to reconstruct destroyed teeth. In this paper, we demonstrate how intact upper molars can be automatically extracted in dental range and intensity images. After normalization of the 3D location, the sizes of the cusps are detected and the distances between them are calculated. In the presented approach, the detection of the upper molar is based on a knowledge-based segmentation which includes anatomic knowledge. After the segmentation of the interesting tooth the central fossa is calculated. The normalization of the spatial location is archieved by aligning the detected fossa with a reference axis. After searching the cusp tips in the range image the image is resized. The methods have been successfully tested on 60 images. The results have been compared with the results of a dentist's evaluation on a sample of 20 images. The results will be further used for automatic production of tooth inlays.

  16. Clinical Application of Solid Model Based on Trabecular Tibia Bone CT Images Created by 3D Printer.

    Science.gov (United States)

    Cho, Jaemo; Park, Chan-Soo; Kim, Yeoun-Jae; Kim, Kwang Gi

    2015-07-01

    The aim of this work is to use a 3D solid model to predict the mechanical loads of human bone fracture risk associated with bone disease conditions according to biomechanical engineering parameters. We used special image processing tools for image segmentation and three-dimensional (3D) reconstruction to generate meshes, which are necessary for the production of a solid model with a 3D printer from computed tomography (CT) images of the human tibia's trabecular and cortical bones. We examined the defects of the mechanism for the tibia's trabecular bones. Image processing tools and segmentation techniques were used to analyze bone structures and produce a solid model with a 3D printer. These days, bio-imaging (CT and magnetic resonance imaging) devices are able to display and reconstruct 3D anatomical details, and diagnostics are becoming increasingly vital to the quality of patient treatment planning and clinical treatment. Furthermore, radiographic images are being used to study biomechanical systems with several aims, namely, to describe and simulate the mechanical behavior of certain anatomical systems, to analyze pathological bone conditions, to study tissues structure and properties, and to create a solid model using a 3D printer to support surgical planning and reduce experimental costs. These days, research using image processing tools and segmentation techniques to analyze bone structures to produce a solid model with a 3D printer is rapidly becoming very important.

  17. (-)-N-[11C]propyl-norapomorphine: a positron-labeled dopamine agonist for PET imaging of D2 receptors

    International Nuclear Information System (INIS)

    Hwang, Dah-Ren; Kegeles, Lawrence S.; Laruelle, Marc

    2000-01-01

    Imaging neuroreceptors with radiolabeled agonists might provide valuable information on the in vivo agonist affinity states of receptors of interest. We report here the radiosynthesis, biodistribution in rodents, and imaging studies in baboons of [ 11 C]-labeled (-)-N-propyl-norapomorphine [(-)-NPA]. (-)-[ 11 C]NPA was prepared by reacting norapomorphine with [ 11 C]propionyl chloride and a lithium aluminum hydride reduction. [ 11 C]Propionyl chloride was prepared by reacting [ 11 C]CO 2 with ethylmagnesium bromide, followed by reacting with phthaloyl chloride. The radiochemical yield of (-)-[ 11 C]NPA was 2.5% at end of synthesis (EOS), and the synthesis time was 60 min. The specific activity was 1700±1900 mCi/μmol ( N=7; ranged 110-5200 mCi/μmol at EOS). Rodent biodistribution studies showed high uptake of [ 11 C](-)-NPA in D 2 receptor-rich areas, and the striatum/cerebellum ratios were 1.7, 3.4, and 4.4 at 5 min, 30 min, and 60 min postinjection, respectively. Pretreating the animals with haloperidol (1 mg/kg) decreased the striatum/cerebellum ratio at 30 min postinjection to 1.3. (-)-[ 11 C]NPA was also evaluated via baboon positron emission tomography (PET) studies. Under control conditions ( N=4), rapid uptake of the tracer was observed and the striatum/cerebellum ratio reached 2.86±0.15 at 45 min postinjection. Following haloperidol pretreatment (0.2 mg/kg IV), the striatum/cerebellum ratio was 1.29 at 45 min postinjection. The result demonstrated the existence of specific binding of this new tracer to the D 2 receptor. To our knowledge, the current finding of a striatum/cerebellum ratio of 2.8 in baboon was the highest reported with a radiolabeled D 2 agonist. (-)-[ 11 C]NPA is a promising new D 2 agonist PET tracer for probing D 2 receptors in vivo using PET

  18. (-)-N-[(11)C]propyl-norapomorphine: a positron-labeled dopamine agonist for PET imaging of D(2) receptors.

    Science.gov (United States)

    Hwang, D R; Kegeles, L S; Laruelle, M

    2000-08-01

    Imaging neuroreceptors with radiolabeled agonists might provide valuable information on the in vivo agonist affinity states of receptors of interest. We report here the radiosynthesis, biodistribution in rodents, and imaging studies in baboons of [(11)C]-labeled (-)-N-propyl-norapomorphine [(-)-NPA]. (-)-[(11)C]NPA was prepared by reacting norapomorphine with [(11)C]propionyl chloride and a lithium aluminum hydride reduction. [(11)C]Propionyl chloride was prepared by reacting [(11)C]CO(2) with ethylmagnesium bromide, followed by reacting with phthaloyl chloride. The radiochemical yield of (-)-[(11)C]NPA was 2.5% at end of synthesis (EOS), and the synthesis time was 60 min. The specific activity was 1700+/-1900 mCi/micromol ( N=7; ranged 110-5200 mCi/micromol at EOS). Rodent biodistribution studies showed high uptake of [(11)C](-)-NPA in D(2) receptor-rich areas, and the striatum/cerebellum ratios were 1.7, 3.4, and 4.4 at 5 min, 30 min, and 60 min postinjection, respectively. Pretreating the animals with haloperidol (1 mg/kg) decreased the striatum/cerebellum ratio at 30 min postinjection to 1.3. (-)-[(11)C]NPA was also evaluated via baboon positron emission tomography (PET) studies. Under control conditions ( N=4), rapid uptake of the tracer was observed and the striatum/cerebellum ratio reached 2.86+/-0.15 at 45 min postinjection. Following haloperidol pretreatment (0.2 mg/kg IV), the striatum/cerebellum ratio was 1.29 at 45 min postinjection. The result demonstrated the existence of specific binding of this new tracer to the D(2) receptor. To our knowledge, the current finding of a striatum/cerebellum ratio of 2.8 in baboon was the highest reported with a radiolabeled D(2) agonist. (-)-[(11)C]NPA is a promising new D(2) agonist PET tracer for probing D(2) receptors in vivo using PET.

  19. SU-G-BRA-03: PCA Based Imaging Angle Optimization for 2D Cine MRI Based Radiotherapy Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Chen, T; Yue, N; Jabbour, S; Zhang, M [Rutgers University, New Brunswick, NJ (United States)

    2016-06-15

    Purpose: To develop an imaging angle optimization methodology for orthogonal 2D cine MRI based radiotherapy guidance using Principal Component Analysis (PCA) of target motion retrieved from 4DCT. Methods: We retrospectively analyzed 4DCT of 6 patients with lung tumor. A radiation oncologist manually contoured the target volume at the maximal inhalation phase of the respiratory cycle. An object constrained deformable image registration (DIR) method has been developed to track the target motion along the respiration at ten phases. The motion of the center of the target mass has been analyzed using the PCA to find out the principal motion components that were uncorrelated with each other. Two orthogonal image planes for cineMRI have been determined using this method to minimize the through plane motion during MRI based radiotherapy guidance. Results: 3D target respiratory motion for all 6 patients has been efficiently retrieved from 4DCT. In this process, the object constrained DIR demonstrated satisfactory accuracy and efficiency to enable the automatic motion tracking for clinical application. The average motion amplitude in the AP, lateral, and longitudinal directions were 3.6mm (min: 1.6mm, max: 5.6mm), 1.7mm (min: 0.6mm, max: 2.7mm), and 5.6mm (min: 1.8mm, max: 16.1mm), respectively. Based on PCA, the optimal orthogonal imaging planes were determined for cineMRI. The average angular difference between the PCA determined imaging planes and the traditional AP and lateral imaging planes were 47 and 31 degrees, respectively. After optimization, the average amplitude of through plane motion reduced from 3.6mm in AP images to 2.5mm (min:1.3mm, max:3.9mm); and from 1.7mm in lateral images to 0.6mm (min: 0.2mm, max:1.5mm), while the principal in plane motion amplitude increased from 5.6mm to 6.5mm (min: 2.8mm, max: 17mm). Conclusion: DIR and PCA can be used to optimize the orthogonal image planes of cineMRI to minimize the through plane motion during radiotherapy

  20. SU-G-BRA-03: PCA Based Imaging Angle Optimization for 2D Cine MRI Based Radiotherapy Guidance

    International Nuclear Information System (INIS)

    Chen, T; Yue, N; Jabbour, S; Zhang, M

    2016-01-01

    Purpose: To develop an imaging angle optimization methodology for orthogonal 2D cine MRI based radiotherapy guidance using Principal Component Analysis (PCA) of target motion retrieved from 4DCT. Methods: We retrospectively analyzed 4DCT of 6 patients with lung tumor. A radiation oncologist manually contoured the target volume at the maximal inhalation phase of the respiratory cycle. An object constrained deformable image registration (DIR) method has been developed to track the target motion along the respiration at ten phases. The motion of the center of the target mass has been analyzed using the PCA to find out the principal motion components that were uncorrelated with each other. Two orthogonal image planes for cineMRI have been determined using this method to minimize the through plane motion during MRI based radiotherapy guidance. Results: 3D target respiratory motion for all 6 patients has been efficiently retrieved from 4DCT. In this process, the object constrained DIR demonstrated satisfactory accuracy and efficiency to enable the automatic motion tracking for clinical application. The average motion amplitude in the AP, lateral, and longitudinal directions were 3.6mm (min: 1.6mm, max: 5.6mm), 1.7mm (min: 0.6mm, max: 2.7mm), and 5.6mm (min: 1.8mm, max: 16.1mm), respectively. Based on PCA, the optimal orthogonal imaging planes were determined for cineMRI. The average angular difference between the PCA determined imaging planes and the traditional AP and lateral imaging planes were 47 and 31 degrees, respectively. After optimization, the average amplitude of through plane motion reduced from 3.6mm in AP images to 2.5mm (min:1.3mm, max:3.9mm); and from 1.7mm in lateral images to 0.6mm (min: 0.2mm, max:1.5mm), while the principal in plane motion amplitude increased from 5.6mm to 6.5mm (min: 2.8mm, max: 17mm). Conclusion: DIR and PCA can be used to optimize the orthogonal image planes of cineMRI to minimize the through plane motion during radiotherapy

  1. Preparing diagnostic 3D images for image registration with planning CT images

    International Nuclear Information System (INIS)

    Tracton, Gregg S.; Miller, Elizabeth P.; Rosenman, Julian; Chang, Sha X.; Sailer, Scott; Boxwala, Azaz; Chaney, Edward L.

    1997-01-01

    Purpose: Pre-radiotherapy (pre-RT) tomographic images acquired for diagnostic purposes often contain important tumor and/or normal tissue information which is poorly defined or absent in planning CT images. Our two years of clinical experience has shown that computer-assisted 3D registration of pre-RT images with planning CT images often plays an indispensable role in accurate treatment volume definition. Often the only available format of the diagnostic images is film from which the original 3D digital data must be reconstructed. In addition, any digital data, whether reconstructed or not, must be put into a form suitable for incorporation into the treatment planning system. The purpose of this investigation was to identify all problems that must be overcome before this data is suitable for clinical use. Materials and Methods: In the past two years we have 3D-reconstructed 300 diagnostic images from film and digital sources. As a problem was discovered we built a software tool to correct it. In time we collected a large set of such tools and found that they must be applied in a specific order to achieve the correct reconstruction. Finally, a toolkit (ediScan) was built that made all these tools available in the proper manner via a pleasant yet efficient mouse-based user interface. Results: Problems we discovered included different magnifications, shifted display centers, non-parallel image planes, image planes not perpendicular to the long axis of the table-top (shearing), irregularly spaced scans, non contiguous scan volumes, multiple slices per film, different orientations for slice axes (e.g. left-right reversal), slices printed at window settings corresponding to tissues of interest for diagnostic purposes, and printing artifacts. We have learned that the specific steps to correct these problems, in order of application, are: Also, we found that fast feedback and large image capacity (at least 2000 x 2000 12-bit pixels) are essential for practical application

  2. 3D non-rigid surface-based MR-TRUS registration for image-guided prostate biopsy

    Science.gov (United States)

    Sun, Yue; Qiu, Wu; Romagnoli, Cesare; Fenster, Aaron

    2014-03-01

    Two dimensional (2D) transrectal ultrasound (TRUS) guided prostate biopsy is the standard approach for definitive diagnosis of prostate cancer (PCa). However, due to the lack of image contrast of prostate tumors needed to clearly visualize early-stage PCa, prostate biopsy often results in false negatives, requiring repeat biopsies. Magnetic Resonance Imaging (MRI) has been considered to be a promising imaging modality for noninvasive identification of PCa, since it can provide a high sensitivity and specificity for the detection of early stage PCa. Our main objective is to develop and validate a registration method of 3D MR-TRUS images, allowing generation of volumetric 3D maps of targets identified in 3D MR images to be biopsied using 3D TRUS images. Our registration method first makes use of an initial rigid registration of 3D MR images to 3D TRUS images using 6 manually placed approximately corresponding landmarks in each image. Following the manual initialization, two prostate surfaces are segmented from 3D MR and TRUS images and then non-rigidly registered using a thin-plate spline (TPS) algorithm. The registration accuracy was evaluated using 4 patient images by measuring target registration error (TRE) of manually identified corresponding intrinsic fiducials (calcifications and/or cysts) in the prostates. Experimental results show that the proposed method yielded an overall mean TRE of 2.05 mm, which is favorably comparable to a clinical requirement for an error of less than 2.5 mm.

  3. Synthesis and 131I labelling of epidepride as a dopamine D2 receptor imaging agent

    International Nuclear Information System (INIS)

    Yang Min; Hu Mingyang; Pei Zhuguo; Wang Bocheng; Zhou Xingqin

    2001-01-01

    S-(-)-N-[(1-ethyl-2-pyrrolidinyl)methyl]-5-iodo-2, 3-dimethoxybenzamide (Epidepride) and its iodine labeling precursor S-(-)-N-[(1-Ethyl-2-pyrrolidinyl)methyl]-5-tributyltin-2, 3-dimethoxybenzamide are synthesized from 3-methoxy salicylic acid. The labeling precursor is labeled with 131 I by hydrogen peroxide method, and 131 I-epidepride is gained, its radiolabelling yield (RLY) and the radiochemical purity (RCP) are all over 95%. The RCP of 131 I-epidepride is over 90% under 4 degree C after 15 days. 131 I-epidepride has high affinity to dopamine D 2 receptor. The striatal uptake can be blocked completely by spiperone. The striatum and cerebellum uptake ratio can reach 237 at 320 min in rats. The results show that 131 I-epidepride may be used as a dopamine D 2 receptor imaging agent for SPECT

  4. 3D shape recovery from image focus using Gabor features

    Science.gov (United States)

    Mahmood, Fahad; Mahmood, Jawad; Zeb, Ayesha; Iqbal, Javaid

    2018-04-01

    Recovering an accurate and precise depth map from a set of acquired 2-D image dataset of the target object each having different focus information is an ultimate goal of 3-D shape recovery. Focus measure algorithm plays an important role in this architecture as it converts the corresponding color value information into focus information which will be then utilized for recovering depth map. This article introduces Gabor features as focus measure approach for recovering depth map from a set of 2-D images. Frequency and orientation representation of Gabor filter features is similar to human visual system and normally applied for texture representation. Due to its little computational complexity, sharp focus measure curve, robust to random noise sources and accuracy, it is considered as superior alternative to most of recently proposed 3-D shape recovery approaches. This algorithm is deeply investigated on real image sequences and synthetic image dataset. The efficiency of the proposed scheme is also compared with the state of art 3-D shape recovery approaches. Finally, by means of two global statistical measures, root mean square error and correlation, we claim that this approach, in spite of simplicity, generates accurate results.

  5. Registration of 3D FMT and CT Images of Mouse via Affine Transformation using Sequential Monte Carlo

    International Nuclear Information System (INIS)

    Xia Zheng; Zhou Xiaobo; Wong, Stephen T. C.; Sun Youxian

    2007-01-01

    It is difficult to directly co-register the 3D FMT (Fluorescence Molecular Tomography) image of a small tumor in a mouse whose maximal diameter is only a few mm with a larger CT image of the entire animal that spans about ten cm. This paper proposes a new method to register 2D flat and 3D CT image first to facilitate the registration between small 3D FMT images and large CT images. A novel algorithm based on SMC (Sequential Monte Carlo) incorporated with least square operation for the registration between the 2D flat and 3D CT images is introduced and validated with simulated images and real images of mice. The visualization of the preliminary alignment of the 3D FMT and CT image through 2D registration shows promising results

  6. Imaging of D2 dopamine receptors of patients with Parkinson's disease using SPECT and 131I-IBZM

    International Nuclear Information System (INIS)

    Zhang Wei; Wang Jian; Jiang Yuping; Lu Chuanzhen

    2001-01-01

    Objective: To evaluate the usefulness of SPECT with 131 I-IBZM in imaging of D 2 Dopamine receptors in patients with Parkinson's disease (PD). Methods: Six patients which early unmedicated PD, six patients with moderate or advanced PD treated with long-term oral L-Dopa and Four control subjects were investigated with SPECT using 131 I-IBZM as dopamine receptor ligand. The ratio of basal ganglia to occipital cortex (BG/OC) and ratio of basal ganglia to frontal cortex (BG/FC) were calculated as semiquantitative parameter of striatal D 2 dopamine receptor's function. Results: The SPECT images revealed high uptake of IBZM in the basal ganglia. In the early unmedicated PD group, the BG/PC and BG/FC rates were significantly higher in the striatum contralateral to the parkinsonism. In the moderate or advanced PD group, no significant differences were observed bilaterally, and the BG/OC and the BG/FC rates in this group was lower than those of the control. Conclusion: 131 I-IBZM with SPECT imaging is useful in evaluating patients with Parkinson's disease

  7. Perceptual Real-Time 2D-to-3D Conversion Using Cue Fusion.

    Science.gov (United States)

    Leimkuhler, Thomas; Kellnhofer, Petr; Ritschel, Tobias; Myszkowski, Karol; Seidel, Hans-Peter

    2018-06-01

    We propose a system to infer binocular disparity from a monocular video stream in real-time. Different from classic reconstruction of physical depth in computer vision, we compute perceptually plausible disparity, that is numerically inaccurate, but results in a very similar overall depth impression with plausible overall layout, sharp edges, fine details and agreement between luminance and disparity. We use several simple monocular cues to estimate disparity maps and confidence maps of low spatial and temporal resolution in real-time. These are complemented by spatially-varying, appearance-dependent and class-specific disparity prior maps, learned from example stereo images. Scene classification selects this prior at runtime. Fusion of prior and cues is done by means of robust MAP inference on a dense spatio-temporal conditional random field with high spatial and temporal resolution. Using normal distributions allows this in constant-time, parallel per-pixel work. We compare our approach to previous 2D-to-3D conversion systems in terms of different metrics, as well as a user study and validate our notion of perceptually plausible disparity.

  8. A new stationary gridline artifact suppression method based on the 2D discrete wavelet transform

    International Nuclear Information System (INIS)

    Tang, Hui; Tong, Dan; Dong Bao, Xu; Dillenseger, Jean-Louis

    2015-01-01

    Purpose: In digital x-ray radiography, an antiscatter grid is inserted between the patient and the image receptor to reduce scattered radiation. If the antiscatter grid is used in a stationary way, gridline artifacts will appear in the final image. In most of the gridline removal image processing methods, the useful information with spatial frequencies close to that of the gridline is usually lost or degraded. In this study, a new stationary gridline suppression method is designed to preserve more of the useful information. Methods: The method is as follows. The input image is first recursively decomposed into several smaller subimages using a multiscale 2D discrete wavelet transform. The decomposition process stops when the gridline signal is found to be greater than a threshold in one or several of these subimages using a gridline detection module. An automatic Gaussian band-stop filter is then applied to the detected subimages to remove the gridline signal. Finally, the restored image is achieved using the corresponding 2D inverse discrete wavelet transform. Results: The processed images show that the proposed method can remove the gridline signal efficiently while maintaining the image details. The spectra of a 1D Fourier transform of the processed images demonstrate that, compared with some existing gridline removal methods, the proposed method has better information preservation after the removal of the gridline artifacts. Additionally, the performance speed is relatively high. Conclusions: The experimental results demonstrate the efficiency of the proposed method. Compared with some existing gridline removal methods, the proposed method can preserve more information within an acceptable execution time

  9. A new stationary gridline artifact suppression method based on the 2D discrete wavelet transform

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Hui, E-mail: corinna@seu.edu.cn [Laboratory of Image Science and Technology, School of Computer Science and Engineering, Southeast University, Nanjing 210096 (China); Key Laboratory of Computer Network and Information Integration (Southeast University), Ministry of Education, Nanjing 210000 (China); Centre de Recherche en Information Biomédicale sino-français, Laboratoire International Associé, Inserm, Université de Rennes 1, Rennes 35000 (France); Southeast University, Nanjing 210000 (China); Tong, Dan; Dong Bao, Xu [Laboratory of Image Science and Technology, School of Computer Science and Engineering, Southeast University, Nanjing 210096 (China); Dillenseger, Jean-Louis [INSERM, U1099, Rennes F-35000 (France); Université de Rennes 1, LTSI, Rennes F-35000 (France); Centre de Recherche en Information Biomédicale sino-français, Laboratoire International Associé, Inserm, Université de Rennes 1, Rennes 35000 (France); Southeast University, Nanjing 210000 (China)

    2015-04-15

    Purpose: In digital x-ray radiography, an antiscatter grid is inserted between the patient and the image receptor to reduce scattered radiation. If the antiscatter grid is used in a stationary way, gridline artifacts will appear in the final image. In most of the gridline removal image processing methods, the useful information with spatial frequencies close to that of the gridline is usually lost or degraded. In this study, a new stationary gridline suppression method is designed to preserve more of the useful information. Methods: The method is as follows. The input image is first recursively decomposed into several smaller subimages using a multiscale 2D discrete wavelet transform. The decomposition process stops when the gridline signal is found to be greater than a threshold in one or several of these subimages using a gridline detection module. An automatic Gaussian band-stop filter is then applied to the detected subimages to remove the gridline signal. Finally, the restored image is achieved using the corresponding 2D inverse discrete wavelet transform. Results: The processed images show that the proposed method can remove the gridline signal efficiently while maintaining the image details. The spectra of a 1D Fourier transform of the processed images demonstrate that, compared with some existing gridline removal methods, the proposed method has better information preservation after the removal of the gridline artifacts. Additionally, the performance speed is relatively high. Conclusions: The experimental results demonstrate the efficiency of the proposed method. Compared with some existing gridline removal methods, the proposed method can preserve more information within an acceptable execution time.

  10. Internet2-based 3D PET image reconstruction using a PC cluster

    International Nuclear Information System (INIS)

    Shattuck, D.W.; Rapela, J.; Asma, E.; Leahy, R.M.; Chatzioannou, A.; Qi, J.

    2002-01-01

    We describe an approach to fast iterative reconstruction from fully three-dimensional (3D) PET data using a network of PentiumIII PCs configured as a Beowulf cluster. To facilitate the use of this system, we have developed a browser-based interface using Java. The system compresses PET data on the user's machine, sends these data over a network, and instructs the PC cluster to reconstruct the image. The cluster implements a parallelized version of our preconditioned conjugate gradient method for fully 3D MAP image reconstruction. We report on the speed-up factors using the Beowulf approach and the impacts of communication latencies in the local cluster network and the network connection between the user's machine and our PC cluster. (author)

  11. X-ray imaging and 3D reconstruction of in-flight exploding foil initiator flyers

    Energy Technology Data Exchange (ETDEWEB)

    Willey, T. M., E-mail: willey1@llnl.gov; Champley, K., E-mail: champley1@llnl.gov; Hodgin, R.; Lauderbach, L.; Bagge-Hansen, M.; May, C.; Buuren, T. van [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Sanchez, N.; Jensen, B. J. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Iverson, A. [National Security Technologies, LLC, Las Vegas, Nevada 89193 (United States)

    2016-06-21

    Exploding foil initiators (EFIs), also known as slapper initiators or detonators, offer clear safety and timing advantages over other means of initiating detonation in high explosives. This work outlines a new capability for imaging and reconstructing three-dimensional images of operating EFIs. Flyer size and intended velocity were chosen based on parameters of the imaging system. The EFI metal plasma and plastic flyer traveling at 2.5 km/s were imaged with short ∼80 ps pulses spaced 153.4 ns apart. A four-camera system acquired 4 images from successive x-ray pulses from each shot. The first frame was prior to bridge burst, the 2nd images the flyer about 0.16 mm above the surface but edges of the foil and/or flyer are still attached to the substrate. The 3rd frame captures the flyer in flight, while the 4th shows a completely detached flyer in a position that is typically beyond where slappers strike initiating explosives. Multiple acquisitions at different incident angles and advanced computed tomography reconstruction algorithms were used to produce a 3-dimensional image of the flyer at 0.16 and 0.53 mm above the surface. Both the x-ray images and the 3D reconstruction show a strong anisotropy in the shape of the flyer and underlying foil parallel vs. perpendicular to the initiating current and electrical contacts. These results provide detailed flyer morphology during the operation of the EFI.

  12. 3D Tendon Strain Estimation Using High-frequency Volumetric Ultrasound Images: A Feasibility Study.

    Science.gov (United States)

    Carvalho, Catarina; Slagmolen, Pieter; Bogaerts, Stijn; Scheys, Lennart; D'hooge, Jan; Peers, Koen; Maes, Frederik; Suetens, Paul

    2018-03-01

    Estimation of strain in tendons for tendinopathy assessment is a hot topic within the sports medicine community. It is believed that, if accurately estimated, existing treatment and rehabilitation protocols can be improved and presymptomatic abnormalities can be detected earlier. State-of-the-art studies present inaccurate and highly variable strain estimates, leaving this problem without solution. Out-of-plane motion, present when acquiring two-dimensional (2D) ultrasound (US) images, is a known problem and may be responsible for such errors. This work investigates the benefit of high-frequency, three-dimensional (3D) US imaging to reduce errors in tendon strain estimation. Volumetric US images were acquired in silico, in vitro, and ex vivo using an innovative acquisition approach that combines the acquisition of 2D high-frequency US images with a mechanical guided system. An affine image registration method was used to estimate global strain. 3D strain estimates were then compared with ground-truth values and with 2D strain estimates. The obtained results for in silico data showed a mean absolute error (MAE) of 0.07%, 0.05%, and 0.27% for 3D estimates along axial, lateral direction, and elevation direction and a respective MAE of 0.21% and 0.29% for 2D strain estimates. Although 3D could outperform 2D, this does not occur in in vitro and ex vivo settings, likely due to 3D acquisition artifacts. Comparison against the state-of-the-art methods showed competitive results. The proposed work shows that 3D strain estimates are more accurate than 2D estimates but acquisition of appropriate 3D US images remains a challenge.

  13. 3D-SIFT-Flow for atlas-based CT liver image segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yan, E-mail: xuyan04@gmail.com [State Key Laboratory of Software Development Environment and Key Laboratory of Biomechanics and Mechanobiology of Ministry of Education, Beihang University, Beijing 100191, China and Research Institute of Beihang University in Shenzhen and Microsoft Research, Beijing 100080 (China); Xu, Chenchao, E-mail: chenchaoxu33@gmail.com; Kuang, Xiao, E-mail: kuangxiao.ace@gmail.com [School of Biological Science and Medical Engineering, Beihang University, Beijing 100191 (China); Wang, Hongkai, E-mail: wang.hongkai@gmail.com [Department of Biomedical Engineering, Dalian University of Technology, Dalian 116024 (China); Chang, Eric I-Chao, E-mail: eric.chang@microsoft.com [Microsoft Research, Beijing 100080 (China); Huang, Weimin, E-mail: wmhuang@i2r.a-star.edu.sg [Institute for Infocomm Research (I2R), Singapore 138632 (Singapore); Fan, Yubo, E-mail: yubofan@buaa.edu.cn [Key Laboratory of Biomechanics and Mechanobiology of Ministry of Education, Beihang University, Beijing 100191 (China)

    2016-05-15

    Purpose: In this paper, the authors proposed a new 3D registration algorithm, 3D-scale invariant feature transform (SIFT)-Flow, for multiatlas-based liver segmentation in computed tomography (CT) images. Methods: In the registration work, the authors developed a new registration method that takes advantage of dense correspondence using the informative and robust SIFT feature. The authors computed the dense SIFT features for the source image and the target image and designed an objective function to obtain the correspondence between these two images. Labeling of the source image was then mapped to the target image according to the former correspondence, resulting in accurate segmentation. In the fusion work, the 2D-based nonparametric label transfer method was extended to 3D for fusing the registered 3D atlases. Results: Compared with existing registration algorithms, 3D-SIFT-Flow has its particular advantage in matching anatomical structures (such as the liver) that observe large variation/deformation. The authors observed consistent improvement over widely adopted state-of-the-art registration methods such as ELASTIX, ANTS, and multiatlas fusion methods such as joint label fusion. Experimental results of liver segmentation on the MICCAI 2007 Grand Challenge are encouraging, e.g., Dice overlap ratio 96.27% ± 0.96% by our method compared with the previous state-of-the-art result of 94.90% ± 2.86%. Conclusions: Experimental results show that 3D-SIFT-Flow is robust for segmenting the liver from CT images, which has large tissue deformation and blurry boundary, and 3D label transfer is effective and efficient for improving the registration accuracy.

  14. 3D-SIFT-Flow for atlas-based CT liver image segmentation

    International Nuclear Information System (INIS)

    Xu, Yan; Xu, Chenchao; Kuang, Xiao; Wang, Hongkai; Chang, Eric I-Chao; Huang, Weimin; Fan, Yubo

    2016-01-01

    Purpose: In this paper, the authors proposed a new 3D registration algorithm, 3D-scale invariant feature transform (SIFT)-Flow, for multiatlas-based liver segmentation in computed tomography (CT) images. Methods: In the registration work, the authors developed a new registration method that takes advantage of dense correspondence using the informative and robust SIFT feature. The authors computed the dense SIFT features for the source image and the target image and designed an objective function to obtain the correspondence between these two images. Labeling of the source image was then mapped to the target image according to the former correspondence, resulting in accurate segmentation. In the fusion work, the 2D-based nonparametric label transfer method was extended to 3D for fusing the registered 3D atlases. Results: Compared with existing registration algorithms, 3D-SIFT-Flow has its particular advantage in matching anatomical structures (such as the liver) that observe large variation/deformation. The authors observed consistent improvement over widely adopted state-of-the-art registration methods such as ELASTIX, ANTS, and multiatlas fusion methods such as joint label fusion. Experimental results of liver segmentation on the MICCAI 2007 Grand Challenge are encouraging, e.g., Dice overlap ratio 96.27% ± 0.96% by our method compared with the previous state-of-the-art result of 94.90% ± 2.86%. Conclusions: Experimental results show that 3D-SIFT-Flow is robust for segmenting the liver from CT images, which has large tissue deformation and blurry boundary, and 3D label transfer is effective and efficient for improving the registration accuracy.

  15. Accuracy of volume measurement using 3D ultrasound and development of CT-3D US image fusion algorithm for prostate cancer radiotherapy

    International Nuclear Information System (INIS)

    Baek, Jihye; Huh, Jangyoung; Hyun An, So; Oh, Yoonjin; Kim, Myungsoo; Kim, DongYoung; Chung, Kwangzoo; Cho, Sungho; Lee, Rena

    2013-01-01

    Purpose: To evaluate the accuracy of measuring volumes using three-dimensional ultrasound (3D US), and to verify the feasibility of the replacement of CT-MR fusion images with CT-3D US in radiotherapy treatment planning. Methods: Phantoms, consisting of water, contrast agent, and agarose, were manufactured. The volume was measured using 3D US, CT, and MR devices. A CT-3D US and MR-3D US image fusion software was developed using the Insight Toolkit library in order to acquire three-dimensional fusion images. The quality of the image fusion was evaluated using metric value and fusion images. Results: Volume measurement, using 3D US, shows a 2.8 ± 1.5% error, 4.4 ± 3.0% error for CT, and 3.1 ± 2.0% error for MR. The results imply that volume measurement using the 3D US devices has a similar accuracy level to that of CT and MR. Three-dimensional image fusion of CT-3D US and MR-3D US was successfully performed using phantom images. Moreover, MR-3D US image fusion was performed using human bladder images. Conclusions: 3D US could be used in the volume measurement of human bladders and prostates. CT-3D US image fusion could be used in monitoring the target position in each fraction of external beam radiation therapy. Moreover, the feasibility of replacing the CT-MR image fusion to the CT-3D US in radiotherapy treatment planning was verified.

  16. 2-deoxy-2-(18F)fluoro-D-glucose positron emission tomography/computed tomography imaging in paediatric oncology

    Institute of Scientific and Technical Information of China (English)

    John; Freebody; Eva; A; Wegner; Monica; A; Rossleigh

    2014-01-01

    Positron emission tomography(PET) is a minimally in-vasive technique which has been well validated for the diagnosis, staging, monitoring of response to therapy, and disease surveillance of adult oncology patients. Tra-ditionally the value of PET and PET/computed tomogra-phy(CT) hybrid imaging has been less clearly defined for paediatric oncology. However recent evidence has emerged regarding the diagnostic utility of these mo-dalities, and they are becoming increasingly important tools in the evaluation and monitoring of children with known or suspected malignant disease. Important indi-cations for 2-deoxy-2-(18F)fluoro-D-glucose(FDG) PET in paediatric oncology include lymphoma, brain tumours, sarcoma, neuroblastoma, Langerhans cell histiocytosis, urogenital tumours and neurofibromatosis type Ⅰ. This article aims to review current evidence for the use of FDG PET and PET/CT in these indications. Attention will also be given to technical and logistical issues, the description of common imaging pitfalls, and dosimetric concerns as they relate to paediatric oncology.

  17. A 2D/3D image analysis system to track fluorescently labeled structures in rod-shaped cells: application to measure spindle pole asymmetry during mitosis.

    Science.gov (United States)

    Schmitter, Daniel; Wachowicz, Paulina; Sage, Daniel; Chasapi, Anastasia; Xenarios, Ioannis; Simanis; Unser, Michael

    2013-01-01

    The yeast Schizosaccharomyces pombe is frequently used as a model for studying the cell cycle. The cells are rod-shaped and divide by medial fission. The process of cell division, or cytokinesis, is controlled by a network of signaling proteins called the Septation Initiation Network (SIN); SIN proteins associate with the SPBs during nuclear division (mitosis). Some SIN proteins associate with both SPBs early in mitosis, and then display strongly asymmetric signal intensity at the SPBs in late mitosis, just before cytokinesis. This asymmetry is thought to be important for correct regulation of SIN signaling, and coordination of cytokinesis and mitosis. In order to study the dynamics of organelles or large protein complexes such as the spindle pole body (SPB), which have been labeled with a fluorescent protein tag in living cells, a number of the image analysis problems must be solved; the cell outline must be detected automatically, and the position and signal intensity associated with the structures of interest within the cell must be determined. We present a new 2D and 3D image analysis system that permits versatile and robust analysis of motile, fluorescently labeled structures in rod-shaped cells. We have designed an image analysis system that we have implemented as a user-friendly software package allowing the fast and robust image-analysis of large numbers of rod-shaped cells. We have developed new robust algorithms, which we combined with existing methodologies to facilitate fast and accurate analysis. Our software permits the detection and segmentation of rod-shaped cells in either static or dynamic (i.e. time lapse) multi-channel images. It enables tracking of two structures (for example SPBs) in two different image channels. For 2D or 3D static images, the locations of the structures are identified, and then intensity values are extracted together with several quantitative parameters, such as length, width, cell orientation, background fluorescence and

  18. 3D Seismic Imaging using Marchenko Methods

    Science.gov (United States)

    Lomas, A.; Curtis, A.

    2017-12-01

    Marchenko methods are novel, data driven techniques that allow seismic wavefields from sources and receivers on the Earth's surface to be redatumed to construct wavefields with sources in the subsurface - including complex multiply-reflected waves, and without the need for a complex reference model. In turn, this allows subsurface images to be constructed at any such subsurface redatuming points (image or virtual receiver points). Such images are then free of artefacts from multiply-scattered waves that usually contaminate migrated seismic images. Marchenko algorithms require as input the same information as standard migration methods: the full reflection response from sources and receivers at the Earth's surface, and an estimate of the first arriving wave between the chosen image point and the surface. The latter can be calculated using a smooth velocity model estimated using standard methods. The algorithm iteratively calculates a signal that focuses at the image point to create a virtual source at that point, and this can be used to retrieve the signal between the virtual source and the surface. A feature of these methods is that the retrieved signals are naturally decomposed into up- and down-going components. That is, we obtain both the signal that initially propagated upwards from the virtual source and arrived at the surface, separated from the signal that initially propagated downwards. Figure (a) shows a 3D subsurface model with a variable density but a constant velocity (3000m/s). Along the surface of this model (z=0) in both the x and y directions are co-located sources and receivers at 20-meter intervals. The redatumed signal in figure (b) has been calculated using Marchenko methods from a virtual source (1200m, 500m and 400m) to the surface. For comparison the true solution is given in figure (c), and shows a good match when compared to figure (b). While these 2D redatuming and imaging methods are still in their infancy having first been developed in

  19. 3D Segmentations of Neuronal Nuclei from Confocal Microscope Image Stacks

    Directory of Open Access Journals (Sweden)

    Antonio eLaTorre

    2013-12-01

    Full Text Available In this paper, we present an algorithm to create 3D segmentations of neuronal cells from stacks of previously segmented 2D images. The idea behind this proposal is to provide a general method to reconstruct 3D structures from 2D stacks, regardless of how these 2D stacks have been obtained. The algorithm not only reuses the information obtained in the 2D segmentation, but also attempts to correct some typical mistakes made by the 2D segmentation algorithms (for example, under segmentation of tightly-coupled clusters of cells. We have tested our algorithm in a real scenario --- the segmentation of the neuronal nuclei in different layers of the rat cerebral cortex. Several representative images from different layers of the cerebral cortex have been considered and several 2D segmentation algorithms have been compared. Furthermore, the algorithm has also been compared with the traditional 3D Watershed algorithm and the results obtained here show better performance in terms of correctly identified neuronal nuclei.

  20. Fast MR Imaging of the Paediatric Abdomen with CAIPIRINHA-Accelerated T1w 3D FLASH and with High-Resolution T2w HASTE: A Study on Image Quality

    Directory of Open Access Journals (Sweden)

    Mengxia Li

    2015-01-01

    Full Text Available The aim of this study was to explore the applicability of fast MR techniques to routine paediatric abdominopelvic MRI at 1.5 Tesla. “Controlled Aliasing in Parallel Imaging Results in Higher Acceleration-” (CAIPIRINHA- accelerated contrast-enhanced-T1w 3D FLASH imaging was compared to standard T1w 2D FLASH imaging with breath-holding in 40 paediatric patients and to respiratory-triggered T1w TSE imaging in 10 sedated young children. In 20 nonsedated patients, we compared T2w TIRM to fat-saturated T2w HASTE imaging. Two observers performed an independent and blinded assessment of overall image quality. Acquisition time was reduced by the factor of 15 with CAIPIRINHA-accelerated T1w FLASH and by 7 with T2w HASTE. With CAIPIRINHA and with HASTE, there were significantly less motion artefacts in nonsedated patients. In sedated patients, respiratory-triggered T1w imaging in general showed better image quality. However, satisfactory image quality was achieved with CAIPIRINHA in two sedated patients where respiratory triggering failed. In summary, fast scanning with CAIPIRINHA and HASTE presents a reliable high quality alternative to standard sequences in paediatric abdominal MRI. Paediatric patients, in particular, benefit greatly from fast image acquisition with less breath-hold cycles or shorter sedation.

  1. Autonomous Planetary 3-D Reconstruction From Satellite Images

    DEFF Research Database (Denmark)

    Denver, Troelz

    1999-01-01

    is discussed.Based on such features, 3-D representations may be compiled from two or more 2-D satellite images. The main purposes of such a mapping system are extraction of landing sites, objects of scientific interest and general planetary surveying. All data processing is performed autonomously onboard...

  2. Correlation of contrast-detail analysis and clinical image quality assessment in chest radiography with a human cadaver study.

    Science.gov (United States)

    De Crop, An; Bacher, Klaus; Van Hoof, Tom; Smeets, Peter V; Smet, Barbara S; Vergauwen, Merel; Kiendys, Urszula; Duyck, Philippe; Verstraete, Koenraad; D'Herde, Katharina; Thierens, Hubert

    2012-01-01

    To determine the correlation between the clinical and physical image quality of chest images by using cadavers embalmed with the Thiel technique and a contrast-detail phantom. The use of human cadavers fulfilled the requirements of the institutional ethics committee. Clinical image quality was assessed by using three human cadavers embalmed with the Thiel technique, which results in excellent preservation of the flexibility and plasticity of organs and tissues. As a result, lungs can be inflated during image acquisition to simulate the pulmonary anatomy seen on a chest radiograph. Both contrast-detail phantom images and chest images of the Thiel-embalmed bodies were acquired with an amorphous silicon flat-panel detector. Tube voltage (70, 81, 90, 100, 113, 125 kVp), copper filtration (0.1, 0.2, 0.3 mm Cu), and exposure settings (200, 280, 400, 560, 800 speed class) were altered to simulate different quality levels. Four experienced radiologists assessed the image quality by using a visual grading analysis (VGA) technique based on European Quality Criteria for Chest Radiology. The phantom images were scored manually and automatically with use of dedicated software, both resulting in an inverse image quality figure (IQF). Spearman rank correlations between inverse IQFs and VGA scores were calculated. A statistically significant correlation (r = 0.80, P chest radiography. © RSNA, 2011.

  3. Anomaly effects of arrays for 3d geoelectrical resistivity imaging ...

    African Journals Online (AJOL)

    user

    The effectiveness of using a net of orthogonal or parallel sets of two-dimensional (2D) profiles for three- dimensional (3D) geoelectrical resistivity imaging has been evaluated. A series of 2D apparent resistivity data were generated over two synthetic models which represent geological or environmental conditions for a ...

  4. Tomographic spectral imaging: microanalysis in 3D

    International Nuclear Information System (INIS)

    Kotula, P.G.; Keenan, M.R.; Michael, J.R.

    2003-01-01

    Full text: Spectral imaging, where a series of complete x-ray spectra are typically collected from a 2D area, holds great promise for comprehensive near-surface microanalysis. There are however numerous microanalysis problems where 3D chemical information is needed as well. In the SEM, some sort of sectioning (either mechanical or with a focused ion beam (FIB) tool) followed by x-ray mapping has, in the past, been utilized in an attempt to perform 3D microanalysis. Reliance on simple mapping has the potential to miss important chemical features as well as misidentify others. In this paper we will describe the acquisition of serial-section tomographic spectral images (TSI) with a dual-beam FIB/SEM equipped with an EDS system. We will also describe the application of a modified version of our multivariate statistical analysis algorithms to TSIs. Serial sectioning was performed with a FEI DB-235 FIB/SEM. Firstly, the specimen normal was tilted to the optic axis of the FIB column and a trench was milled into the surface of the specimen. A second trench was then milled perpendicular to the first to provide visibility of the entire analysis surface to the x-ray detector. In addition, several fiducial markers were milled into the surface to allow for alignment from slice to slice. The electron column is at an angle of 52 deg to the ion column so the electron beam can 'see' the analysis surface milled by the FIB with no additional specimen tilting or rotation. Likewise the x-ray detector is at a radial angle of 45 deg to the plane of the electron and ion columns (about the electron column) and a take-off-angle of 35 deg with respect to an untilted specimen so it can 'see' the analysis surface as well with no additional sample tilting or rotation. Spectral images were acquired from regions 40 μm wide and 20μm deep for each slice. Approximately 1μm/slice was milled and 10-12 total slices were cut. Spectral images were acquired with a Thermo NORAN Vantage (Digital imaging

  5. Visualization of cranial nerves by MR cisternography using 3D FASE. Comparison with 2D FSE

    Energy Technology Data Exchange (ETDEWEB)

    Asakura, Hirofumi; Nakano, Satoru; Togami, Taro [Kagawa Medical School, Miki (Japan)] (and others)

    2001-03-01

    MR cisternography using 3D FASE was compared with that of 2D FSE in regard to visualization of normal cranial nerves. In a phantom study, contrast-to-noise ratio (C/N) of fine structures was better in 3D FASE images than in 2D FSE. In clinical cases, visualization of trigeminal nerve, abducent nerve, and facial/vestibulo-cochlear nerve were evaluated. Each cranial nerve was visualized better in 3D FASE images than in 2D FSE, with a significant difference (p<0.05). (author)

  6. Visualization of cranial nerves by MR cisternography using 3D FASE. Comparison with 2D FSE

    International Nuclear Information System (INIS)

    Asakura, Hirofumi; Nakano, Satoru; Togami, Taro

    2001-01-01

    MR cisternography using 3D FASE was compared with that of 2D FSE in regard to visualization of normal cranial nerves. In a phantom study, contrast-to-noise ratio (C/N) of fine structures was better in 3D FASE images than in 2D FSE. In clinical cases, visualization of trigeminal nerve, abducent nerve, and facial/vestibulo-cochlear nerve were evaluated. Each cranial nerve was visualized better in 3D FASE images than in 2D FSE, with a significant difference (p<0.05). (author)

  7. Evaluation of a software package for automated quality assessment of contrast detail images-comparison with subjective visual assessment

    International Nuclear Information System (INIS)

    Pascoal, A; Lawinski, C P; Honey, I; Blake, P

    2005-01-01

    Contrast detail analysis is commonly used to assess image quality (IQ) associated with diagnostic imaging systems. Applications include routine assessment of equipment performance and optimization studies. Most frequently, the evaluation of contrast detail images involves human observers visually detecting the threshold contrast detail combinations in the image. However, the subjective nature of human perception and the variations in the decision threshold pose limits to the minimum image quality variations detectable with reliability. Objective methods of assessment of image quality such as automated scoring have the potential to overcome the above limitations. A software package (CDRAD analyser) developed for automated scoring of images produced with the CDRAD test object was evaluated. Its performance to assess absolute and relative IQ was compared with that of an average observer. Results show that the software does not mimic the absolute performance of the average observer. The software proved more sensitive and was able to detect smaller low-contrast variations. The observer's performance was superior to the software's in the detection of smaller details. Both scoring methods showed frequent agreement in the detection of image quality variations resulting from changes in kVp and KERMA detector , which indicates the potential to use the software CDRAD analyser for assessment of relative IQ

  8. T2*-weighted image/T2-weighted image fusion in postimplant dosimetry of prostate brachytherapy

    International Nuclear Information System (INIS)

    Katayama, Norihisa; Takemoto, Mitsuhiro; Yoshio, Kotaro

    2011-01-01

    Computed tomography (CT)/magnetic resonance imaging (MRI) fusion is considered to be the best method for postimplant dosimetry of permanent prostate brachytherapy; however, it is inconvenient and costly. In T2 * -weighted image (T2 * -WI), seeds can be easily detected without the use of an intravenous contrast material. We present a novel method for postimplant dosimetry using T2 * -WI/T2-weighted image (T2-WI) fusion. We compared the outcomes of T2 * -WI/T2-WI fusion-based and CT/T2-WI fusion-based postimplant dosimetry. Between April 2008 and July 2009, 50 consecutive prostate cancer patients underwent brachytherapy. All the patients were treated with 144 Gy of brachytherapy alone. Dose-volume histogram (DVH) parameters (prostate D90, prostate V100, prostate V150, urethral D10, and rectal D2cc) were prospectively compared between T2 * -WI/T2-WI fusion-based and CT/T2-WI fusion-based dosimetry. All the DVH parameters estimated by T2 * -WI/T2-WI fusion-based dosimetry strongly correlated to those estimated by CT/T2-WI fusion-based dosimetry (0.77≤ R ≤0.91). No significant difference was observed in these parameters between the two methods, except for prostate V150 (p=0.04). These results show that T2 * -WI/T2-WI fusion-based dosimetry is comparable or superior to MRI-based dosimetry as previously reported, because no intravenous contrast material is required. For some patients, rather large differences were observed in the value between the 2 methods. We thought these large differences were a result of seed miscounts in T2 * -WI and shifts in fusion. Improving the image quality of T2 * -WI and the image acquisition speed of T2 * -WI and T2-WI may decrease seed miscounts and fusion shifts. Therefore, in the future, T2 * -WI/T2-WI fusion may be more useful for postimplant dosimetry of prostate brachytherapy. (author)

  9. Watching Silica's Dance: Imaging the Structure and Dynamics of the Atomic (Re-) Arrangements in 2D Glass

    Science.gov (United States)

    Muller, David

    2014-03-01

    Even though glasses are almost ubiquitous--in our windows, on our iPhones, even on our faces--they are also mysterious. Because glasses are notoriously difficult to study, basic questions like: ``How are the atoms arranged? Where and how do glasses break?'' are still under contention. We use aberration corrected transmission electron microscopy (TEM) to image the atoms in a new two-dimensional phase of silica glass - freestanding it becomes the world's thinnest pane of glass at only 3-atoms thick, and take a unique look into these questions. Using atom-by-atom imaging and spectroscopy, we are able to reconstruct the full structure and bonding of this 2D glass and identify it as a bi-tetrahedral layer of SiO2. Our images also strikingly resemble Zachariasen's original cartoon models of glasses, drawn in 1932. As such, our work realizes an 80-year-old vision for easily understandable glassy systems and introduces promising methods to test theoretical predictions against experimental data. We image atoms in the disordered solid and track their motions in response to local strain. We directly obtain ring statistics and pair distribution functions that span short-, medium-, and long-range order, and test these against long-standing theoretical predictions of glass structure and dynamics. We use the electron beam to excite atomic rearrangements, producing surprisingly rich and beautiful videos of how a glass bends and breaks, as well as the exchange of atoms at a solid/liquid interface. Detailed analyses of these videos reveal a complex dance of elastic and plastic deformations, phase transitions, and their interplay. These examples illustrate the wide-ranging and fundamental materials physics that can now be studied at atomic-resolution via transmission electron microscopy of two-dimensional glasses. Work in collaboration with: S. Kurasch, U. Kaiser, R. Hovden, Q. Mao, J. Kotakoski, J. S. Alden, A. Shekhawat, A. A. Alemi, J. P. Sethna, P. L. McEuen, A.V. Krasheninnikov

  10. Whole-heart coronary MRA with 3D affine motion correction using 3D image-based navigation.

    Science.gov (United States)

    Henningsson, Markus; Prieto, Claudia; Chiribiri, Amedeo; Vaillant, Ghislain; Razavi, Reza; Botnar, René M

    2014-01-01

    Robust motion correction is necessary to minimize respiratory motion artefacts in coronary MR angiography (CMRA). The state-of-the-art method uses a 1D feet-head translational motion correction approach, and data acquisition is limited to a small window in the respiratory cycle, which prolongs the scan by a factor of 2-3. The purpose of this work was to implement 3D affine motion correction for Cartesian whole-heart CMRA using a 3D navigator (3D-NAV) to allow for data acquisition throughout the whole respiratory cycle. 3D affine transformations for different respiratory states (bins) were estimated by using 3D-NAV image acquisitions which were acquired during the startup profiles of a steady-state free precession sequence. The calculated 3D affine transformations were applied to the corresponding high-resolution Cartesian image acquisition which had been similarly binned, to correct for respiratory motion between bins. Quantitative and qualitative comparisons showed no statistical difference between images acquired with the proposed method and the reference method using a diaphragmatic navigator with a narrow gating window. We demonstrate that 3D-NAV and 3D affine correction can be used to acquire Cartesian whole-heart 3D coronary artery images with 100% scan efficiency with similar image quality as with the state-of-the-art gated and corrected method with approximately 50% scan efficiency. Copyright © 2013 Wiley Periodicals, Inc.

  11. Improved visualization of collateral ligaments of the ankle: multiplanar reconstructions based on standard 2D turbo spin-echo MR images

    International Nuclear Information System (INIS)

    Duc, Sylvain R.; Mengiardi, Bernard; Pfirrmann, Christian W.A.; Hodler, Juerg; Zanetti, Marco

    2007-01-01

    The purpose of the study was to evaluate the visualization of the collateral ankle ligaments on multiplanar reconstructions (MPR) based on standard 2D turbo spin-echo images. Coronal and axial T2-weighted turbo spin-echo and MPR angled parallel to the course of the ligaments of 15 asymptomatic and 15 symptomatic ankles were separately analyzed by two musculoskeletal radiologists. Image quality was assessed in the asymptomatic ankles qualitatively. In the symptomatic ankles interobserver agreement and reader confidence was determined for each ligament. On MPR the tibionavicular and calcaneofibular ligaments were more commonly demonstrated on a single image than on standard MR images (reader 1: 13 versus 0, P=0.002; reader 2: 14 versus 1, P=0.001 and reader 1: 13 versus 2, P=0.001; reader 2: 14 versus 0, P<0.001). The tibionavicular ligament was considered to be better delineated on MPR by reader 1 (12 versus 3, P=0.031). In the symptomatic ankles, reader confidence was greater with MPR for all ligaments except for the tibiocalcanear ligament (both readers) and the anterior and posterior talofibular ligaments (for reader 2). Interobserver agreement was increased with MPR for the tibionavicular ligament. Multiplanar reconstructions of 2D turbo spin-echo images improve the visualization of the tibionavicular and calcaneofibular ligaments and strengthen diagnostic confidence for these ligaments. (orig.)

  12. Detection of hypoxic-ischemic brain injury with 3D-enhanced T2* weighted angiography (ESWAN) imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gang, QiangQiang, E-mail: rousikang@163.com; Zhang, Jianing, E-mail: 1325916060@qq.com; Hao, Peng, E-mail: 1043600590@qq.com; Xu, Yikai, E-mail: yikaivip@163.com

    2013-11-01

    Objective: To demonstrate the use of 3D-enhanced T2* weighted angiography (ESWAN) imaging for the observation and quantification of the evolution of brain injury induced by a recently developed model of hypoxic-ischemic brain injury (HI/R) in neonatal piglets. Methods: For these experiments, newborn piglets were subjected to HI/R injury, during which ESWAN scanning was performed, followed by H and E staining and immunohistochemistry of AQP-4 expression. Results: In the striatum, values from T2* weighted magnetic resonance imaging (MRI) increased and reached their highest level at 3 days post injury, whereas T2* values increased and peaked at 24 h in the subcortical region. The change in T2* values was concordant with brain edema. Phase values in the subcortical border region were not dependent on time post-injury. Magnitude values were significantly different from the control group, and increased gradually over time in the subcortical border region. Susceptibility-weighted images (SWI) indicated small petechial hemorrhages in the striatum and thalamus, as well as dilated intramedullary veins. Conclusion: SWI images can be used to detect white and gray matter microhemorrhages and dilated intramedullary veins. The T2*, phase, and magnitude map can also reflect the development of brain injury. Our data illustrate that ESWAN imaging can increase the diagnostic sensitivity and specificity of MRI in neonatal hypoxic-ischemic encephalopathy.

  13. Detection of hypoxic-ischemic brain injury with 3D-enhanced T2* weighted angiography (ESWAN) imaging

    International Nuclear Information System (INIS)

    Gang, QiangQiang; Zhang, Jianing; Hao, Peng; Xu, Yikai

    2013-01-01

    Objective: To demonstrate the use of 3D-enhanced T2* weighted angiography (ESWAN) imaging for the observation and quantification of the evolution of brain injury induced by a recently developed model of hypoxic-ischemic brain injury (HI/R) in neonatal piglets. Methods: For these experiments, newborn piglets were subjected to HI/R injury, during which ESWAN scanning was performed, followed by H and E staining and immunohistochemistry of AQP-4 expression. Results: In the striatum, values from T2* weighted magnetic resonance imaging (MRI) increased and reached their highest level at 3 days post injury, whereas T2* values increased and peaked at 24 h in the subcortical region. The change in T2* values was concordant with brain edema. Phase values in the subcortical border region were not dependent on time post-injury. Magnitude values were significantly different from the control group, and increased gradually over time in the subcortical border region. Susceptibility-weighted images (SWI) indicated small petechial hemorrhages in the striatum and thalamus, as well as dilated intramedullary veins. Conclusion: SWI images can be used to detect white and gray matter microhemorrhages and dilated intramedullary veins. The T2*, phase, and magnitude map can also reflect the development of brain injury. Our data illustrate that ESWAN imaging can increase the diagnostic sensitivity and specificity of MRI in neonatal hypoxic-ischemic encephalopathy

  14. Fast fluid-attenuated inversion-recovery imaging: first experience with a 3D version in epilepsy

    International Nuclear Information System (INIS)

    Wieshmann, U.C.; Symms, M.R.; Bartlett, P.A.; Shorvon, S.D.; Barker, G.J.; Stevens, J.M.

    1998-01-01

    We developed a 3D version of fast fluid-attenuated inversion-recovery imaging (FLAIR) which provides images with a slice thickness of 1.5 mm. We present our initial experience with 3D fast FLAIR in patients with epilepsy. We compared 3D fast FLAIR (slice thickness 1.5 mm), 2D fast FLAIR (slice thickness 5 mm) and a 3D spoiled GRASS (IRSPGR) sequence (slice thickness 1.5 mm) in 10 patients with lesional epilepsy (head injury 1, hippocampal sclerosis 2, low-grade glioma 2, dysembryoplastic neuroepithelial tumour 2, polymicrogyria 1, perinatal infarct 1 and presumed thrombosed aneurysm 1). Both 2D and 3D fast FLAIR sequences yielded higher conspicuity for lesions than the T1-weighted IRSPGR sequence, except in the patient with polymicrogyria. The extent of the lesion, in particular that of low-grade tumours, was best assessed on 3D fast FLAIR images. 3D fast FLAIR may be a useful additional tool especially for imaging low-grade tumours. (orig.)

  15. 4D MR imaging using robust internal respiratory signal

    International Nuclear Information System (INIS)

    Hui, CheukKai; Wen, Zhifei; Beddar, Sam; Stemkens, Bjorn; Tijssen, R H N; Van den Berg, C A T; Hwang, Ken-Pin

    2016-01-01

    The purpose of this study is to investigate the feasibility of using internal respiratory (IR) surrogates to sort four-dimensional (4D) magnetic resonance (MR) images. The 4D MR images were constructed by acquiring fast 2D cine MR images sequentially, with each slice scanned for more than one breathing cycle. The 4D volume was then sorted retrospectively using the IR signal. In this study, we propose to use multiple low-frequency components in the Fourier space as well as the anterior body boundary as potential IR surrogates. From these potential IR surrogates, we used a clustering algorithm to identify those that best represented the respiratory pattern to derive the IR signal. A study with healthy volunteers was performed to assess the feasibility of the proposed IR signal. We compared this proposed IR signal with the respiratory signal obtained using respiratory bellows. Overall, 99% of the IR signals matched the bellows signals. The average difference between the end inspiration times in the IR signal and bellows signal was 0.18 s in this cohort of matching signals. For the acquired images corresponding to the other 1% of non-matching signal pairs, the respiratory motion shown in the images was coherent with the respiratory phases determined by the IR signal, but not the bellows signal. This suggested that the IR signal determined by the proposed method could potentially correct the faulty bellows signal. The sorted 4D images showed minimal mismatched artefacts and potential clinical applicability. The proposed IR signal therefore provides a feasible alternative to effectively sort MR images in 4D. (paper)

  16. Complexity and distortion analysis on methods for unrolling 3D to 2D fingerprints

    CSIR Research Space (South Africa)

    Mlambo, CS

    2015-11-01

    Full Text Available and studies involve the application of three-dimensional (3D) fingerprint systems, where the details of the finger are captured using 3D technologies and the captured 3D fingerprints are converted into two-dimensional (2D) fingerprints. This paper presents a...

  17. Dynamic Downlink Spectrum Access for D2D-Enabled Heterogeneous Networks

    KAUST Repository

    Radaydeh, Redha Mahmoud Mesleh

    2018-01-15

    This paper proposes new approaches for underlay device- to-device (D2D) communication in spectrum-shared het- erogeneous cellular networks. It considers devices that share downlink resources and have an enabled D2D feature to improve coverage. The mode of operation classifies devices according to their experienced base station (BS) coverage, potential to be served by BS, ability of BS to meet their quality of service (QoS), and their downlink resources occupancy. The initiation of D2D cooperation is conditioned on proposed provisional access by an active device, wherein its serving BS attempts to meet its QoS using as low number of spectrum channels as possible, while treating remaining channels for feasible D2D cooperation. Detailed formulations for the mode of operation and a proposed D2D path allocation scheme are presented under perfect and imperfect operation scenarios. The developed results are generally applicable for any performance metric and network model.

  18. Interaction of image noise, spatial resolution, and low contrast fine detail preservation in digital image processing

    Science.gov (United States)

    Artmann, Uwe; Wueller, Dietmar

    2009-01-01

    We present a method to improve the validity of noise and resolution measurements on digital cameras. If non-linear adaptive noise reduction is part of the signal processing in the camera, the measurement results for image noise and spatial resolution can be good, while the image quality is low due to the loss of fine details and a watercolor like appearance of the image. To improve the correlation between objective measurement and subjective image quality we propose to supplement the standard test methods with an additional measurement of the texture preserving capabilities of the camera. The proposed method uses a test target showing white Gaussian noise. The camera under test reproduces this target and the image is analyzed. We propose to use the kurtosis of the derivative of the image as a metric for the texture preservation of the camera. Kurtosis is a statistical measure for the closeness of a distribution compared to the Gaussian distribution. It can be shown, that the distribution of digital values in the derivative of the image showing the chart becomes the more leptokurtic (increased kurtosis) the stronger the noise reduction has an impact on the image.

  19. Automatic generation of medium-detailed 3D models of buildings based on CAD data

    NARCIS (Netherlands)

    Dominguez-Martin, B.; Van Oosterom, P.; Feito-Higueruela, F.R.; Garcia-Fernandez, A.L.; Ogayar-Anguita, C.J.

    2015-01-01

    We present the preliminary results of a work in progress which aims to obtain a software system able to automatically generate a set of diverse 3D building models with a medium level of detail, that is, more detailed that a mere parallelepiped, but not as detailed as a complete geometric

  20. BranchAnalysis2D/3D automates morphometry analyses of branching structures.

    Science.gov (United States)

    Srinivasan, Aditya; Muñoz-Estrada, Jesús; Bourgeois, Justin R; Nalwalk, Julia W; Pumiglia, Kevin M; Sheen, Volney L; Ferland, Russell J

    2018-01-15

    Morphometric analyses of biological features have become increasingly common in recent years with such analyses being subject to a large degree of observer bias, variability, and time consumption. While commercial software packages exist to perform these analyses, they are expensive, require extensive user training, and are usually dependent on the observer tracing the morphology. To address these issues, we have developed a broadly applicable, no-cost ImageJ plugin we call 'BranchAnalysis2D/3D', to perform morphometric analyses of structures with branching morphologies, such as neuronal dendritic spines, vascular morphology, and primary cilia. Our BranchAnalysis2D/3D algorithm allows for rapid quantification of the length and thickness of branching morphologies, independent of user tracing, in both 2D and 3D data sets. We validated the performance of BranchAnalysis2D/3D against pre-existing software packages using trained human observers and images from brain and retina. We found that the BranchAnalysis2D/3D algorithm outputs results similar to available software (i.e., Metamorph, AngioTool, Neurolucida), while allowing faster analysis times and unbiased quantification. BranchAnalysis2D/3D allows inexperienced observers to output results like a trained observer but more efficiently, thereby increasing the consistency, speed, and reliability of morphometric analyses. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. 3D high-resolution radar imaging of small body interiors

    Science.gov (United States)

    Sava, Paul; Asphaug, Erik

    2017-10-01

    Answering fundamental questions about the origin and evolution of small planetary bodies hinges on our ability to image their interior structure in detail and at high resolution (Asphaug, 2009). We often infer internal structure from surface observations, e.g. that comet 67P/Churyumov-Gerasimenko is a primordial agglomeration of cometesimals (Massironi et al., 2015). However, the interior structure is not easily accessible without systematic imaging using, e.g., radar transmission and reflection data, as suggested by the CONSERT experiment on Rosetta. Interior imaging depends on observations from multiple viewpoints, as in medical tomography.We discuss radar imaging using methodology adapted from terrestrial exploration seismology (Sava et al., 2015). We primarily focus on full wavefield methods that facilitate high quality imaging of small body interiors characterized by complex structure and large contrasts of physical properties. We consider the case of a monostatic system (co-located transmitters and receivers) operated at two frequency bands, centered around 5 and 15 MHz, from a spacecraft in slow polar orbit around a spinning comet nucleus. Assuming that the spin period is significantly (e.g. 5x) faster than the orbital period, this configuration allows repeated views from multiple directions (Safaeinili et al., 2002)Using realistic numerical experiments, we argue that (1) the comet/asteroid imaging problem is intrinsically 3D and conventional SAR methodology does not satisfy imaging, sampling and resolution requirements; (2) imaging at different frequency bands can provide information about internal surfaces (through migration) and internal volumes (through tomography); (3) interior imaging can be accomplished progressively as data are being acquired through successive orbits around the studied object; (4) imaging resolution can go beyond the apparent radar frequency band by deconvolution of the point-spread-function characterizing the imaging system; and (5

  2. Progress report on first year of WP5.2. Including detailed description of planned research for WP 5.2

    Energy Technology Data Exchange (ETDEWEB)

    Ellemers, N.; Van Dijk, E.; Terwel, B.; De Vries, G. [Leiden University, Leiden (Netherlands)

    2010-10-15

    This document contains the progress report on the first half year of the CATO-2 WP5.2 PhD project 'Framing effects in communication about CCS'. In the first few months a literature study has been conducted, both on (factors that influence) public perceptions and acceptance of CCS, and on framing. In the last two month, a first study was designed. This study consists of an experiment designed to examine how framing a company's involvement in CCS in terms of economic benefits and/or CSR of the organization affects the corporate image, trust, and perceived 'greenwashing' (deceit). Furthermore, this experiment serves to test the quality of newly developed questionnaires to measure these variables. In addition, this document contains a detailed description of the research planned for WP5.2 written by senior (CATO-2) researchers from January 2010 on. The objective of the research planned for WP5.2 is to examine whether framing of communications by an organization can improve the perceived credibility and trustworthiness of the organization and the information provided. This issue will be examined by a combination of experimental studies and a survey-type study.

  3. Targeted 2D/3D registration using ray normalization and a hybrid optimizer

    International Nuclear Information System (INIS)

    Dey, Joyoni; Napel, Sandy

    2006-01-01

    X-ray images are often used to guide minimally invasive procedures in interventional radiology. The use of a preoperatively obtained 3D volume can enhance the visualization needed for guiding catheters and other surgical devices. However, for intraoperative usefulness, the 3D dataset needs to be registered to the 2D x-ray images of the patient. We investigated the effect of targeting subvolumes of interest in the 3D datasets and registering the projections with C-arm x-ray images. We developed an intensity-based 2D/3D rigid-body registration using a Monte Carlo-based hybrid algorithm as the optimizer, using a single view for registration. Pattern intensity (PI) and mutual information (MI) were two metrics tested. We used normalization of the rays to address the problems due to truncation in 3D necessary for targeting. We tested the algorithm on a C-arm x-ray image of a pig's head and a 3D dataset reconstructed from multiple views of the C-arm. PI and MI were comparable in performance. For two subvolumes starting with a set of initial poses from +/-15 mm in x, from +/-3 mm (random), in y and z and +/-4 deg in the three angles, the robustness was 94% for PI and 91% for MI, with accuracy of 2.4 mm (PI) and 2.6 mm (MI), using the hybrid algorithm. The hybrid optimizer, when compared with a standard Powell's direction set method, increased the robustness from 59% (Powell) to 94% (hybrid). Another set of 50 random initial conditions from [+/-20] mm in x,y,z and [+/-10] deg in the three angles, yielded robustness of 84% (hybrid) versus 38% (Powell) using PI as metric, with accuracies 2.1 mm (hybrid) versus 2.0 mm (Powell)

  4. Author Details

    African Journals Online (AJOL)

    Rakotonirina, Alice. Vol 2, No 2 (2002) - Articles Effect of the decoction of rhizomes of Cyperus articulatus on bicuculline-, N-methyl-D-aspartate- and strychnine-induced behavioural excitation and convulsions in mice. Details PDF · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians ...

  5. 3D imaging by serial block face scanning electron microscopy for materials science using ultramicrotomy

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Teruo, E-mail: t.hashimoto@manchester.ac.uk; Thompson, George E.; Zhou, Xiaorong; Withers, Philip J.

    2016-04-15

    Mechanical serial block face scanning electron microscopy (SBFSEM) has emerged as a means of obtaining three dimensional (3D) electron images over volumes much larger than possible by focused ion beam (FIB) serial sectioning and at higher spatial resolution than achievable with conventional X-ray computed tomography (CT). Such high resolution 3D electron images can be employed for precisely determining the shape, volume fraction, distribution and connectivity of important microstructural features. While soft (fixed or frozen) biological samples are particularly well suited for nanoscale sectioning using an ultramicrotome, the technique can also produce excellent 3D images at electron microscope resolution in a time and resource-efficient manner for engineering materials. Currently, a lack of appreciation of the capabilities of ultramicrotomy and the operational challenges associated with minimising artefacts for different materials is limiting its wider application to engineering materials. Consequently, this paper outlines the current state of the art for SBFSEM examining in detail how damage is introduced during slicing and highlighting strategies for minimising such damage. A particular focus of the study is the acquisition of 3D images for a variety of metallic and coated systems. - Highlights: • The roughness of the ultramicrotomed block face of AA2024 in Al area was 1.2 nm. • Surface texture associated with chattering was evident in grains with 45° diamond knife. • A 76° rake angle minimises the stress on the block face. • Using the oscillating knife with a cutting speed of 0.04 mms{sup −1} minimised the surface texture. • A variety of material applications were presented.

  6. Determination of connected components inthe analysis of homogeneous and detail zonesin color images

    Directory of Open Access Journals (Sweden)

    Cristina Pérez-Benito

    2018-02-01

    Full Text Available A model based on local graphs to classify pixels coming from at or detail regions of an image is presented. For each pixel a local graph is dened. Its structure will depend on the similarity between neighbouring pixels. Its features allow us to classify each image pixel as belonging to one type of region or the other. This classication is an essential pre-processing technique for many Computer Vision tools, such as smoothingor sharpening of digital color images.

  7. Performance evaluation of 3-D enhancement filters for detection of lung cancer from 3-D chest X-ray CT images

    International Nuclear Information System (INIS)

    Shimizu, Akinobu; Hagai, Makoto; Toriwaki, Jun-ichiro; Hasegawa, Jun-ichi.

    1995-01-01

    This paper evaluates the performance of several three dimensional enhancement filters used in procedures for detecting lung cancer shadows from three dimensional (3D) chest X-ray CT images. Two dimensional enhancement filters such as Min-DD filter, Contrast filter and N-Quoit filter have been proposed for enhancing cancer shadows in conventional 2D X-ray images. In this paper, we extend each of these 2D filters to a 3D filter and evaluate its performance experimentally by using CT images with artificial and true lung cancer shadows. As a result, we find that these 3D filters are effective for determining the position of a lung cancer shadow in a 3D chest CT image, as compared with the simple procedure such as smoothing filter, and that the performance of these filters become lower in the hilar area due to the influence of the vessel shadows. (author)

  8. Web tools for large-scale 3D biological images and atlases

    Directory of Open Access Journals (Sweden)

    Husz Zsolt L

    2012-06-01

    Full Text Available Abstract Background Large-scale volumetric biomedical image data of three or more dimensions are a significant challenge for distributed browsing and visualisation. Many images now exceed 10GB which for most users is too large to handle in terms of computer RAM and network bandwidth. This is aggravated when users need to access tens or hundreds of such images from an archive. Here we solve the problem for 2D section views through archive data delivering compressed tiled images enabling users to browse through very-large volume data in the context of a standard web-browser. The system provides an interactive visualisation for grey-level and colour 3D images including multiple image layers and spatial-data overlay. Results The standard Internet Imaging Protocol (IIP has been extended to enable arbitrary 2D sectioning of 3D data as well a multi-layered images and indexed overlays. The extended protocol is termed IIP3D and we have implemented a matching server to deliver the protocol and a series of Ajax/Javascript client codes that will run in an Internet browser. We have tested the server software on a low-cost linux-based server for image volumes up to 135GB and 64 simultaneous users. The section views are delivered with response times independent of scale and orientation. The exemplar client provided multi-layer image views with user-controlled colour-filtering and overlays. Conclusions Interactive browsing of arbitrary sections through large biomedical-image volumes is made possible by use of an extended internet protocol and efficient server-based image tiling. The tools open the possibility of enabling fast access to large image archives without the requirement of whole image download and client computers with very large memory configurations. The system was demonstrated using a range of medical and biomedical image data extending up to 135GB for a single image volume.

  9. Crack detection using image processing

    International Nuclear Information System (INIS)

    Moustafa, M.A.A

    2010-01-01

    This thesis contains five main subjects in eight chapters and two appendices. The first subject discus Wiener filter for filtering images. In the second subject, we examine using different methods, as Steepest Descent Algorithm (SDA) and the Wavelet Transformation, to detect and filling the cracks, and it's applications in different areas as Nano technology and Bio-technology. In third subject, we attempt to find 3-D images from 1-D or 2-D images using texture mapping with Open Gl under Visual C ++ language programming. The fourth subject consists of the process of using the image warping methods for finding the depth of 2-D images using affine transformation, bilinear transformation, projective mapping, Mosaic warping and similarity transformation. More details about this subject will be discussed below. The fifth subject, the Bezier curves and surface, will be discussed in details. The methods for creating Bezier curves and surface with unknown distribution, using only control points. At the end of our discussion we will obtain the solid form, using the so called NURBS (Non-Uniform Rational B-Spline); which depends on: the degree of freedom, control points, knots, and an evaluation rule; and is defined as a mathematical representation of 3-D geometry that can accurately describe any shape from a simple 2-D line, circle, arc, or curve to the most complex 3-D organic free-form surface or (solid) which depends on finding the Bezier curve and creating family of curves (surface), then filling in between to obtain the solid form. Another representation for this subject is concerned with building 3D geometric models from physical objects using image-based techniques. The advantage of image techniques is that they require no expensive equipment; we use NURBS, subdivision surface and mesh for finding the depth of any image with one still view or 2D image. The quality of filtering depends on the way the data is incorporated into the model. The data should be treated with

  10. Novel 2D-sequential color code system employing Image Sensor Communications for Optical Wireless Communications

    Directory of Open Access Journals (Sweden)

    Trang Nguyen

    2016-06-01

    Full Text Available The IEEE 802.15.7r1 Optical Wireless Communications Task Group (TG7r1, also known as the revision of the IEEE 802.15.7 Visible Light Communication standard targeting the commercial usage of visible light communication systems, is of interest in this paper. The paper is mainly concerned with Image Sensor Communications (ISC of TG7r1; however, the major challenge facing ISC, as addressed in the Technical Consideration Document (TCD of TG7r1, is Image Sensor Compatibility among the variety of different commercial cameras on the market. One of the most challenging but interesting compatibility requirements is the need to support the verified presence of frame rate variation. This paper proposes a novel design for 2D-sequential color code. Compared to a QR-code-based sequential transmission, the proposed design of 2D-sequential code can overcome the above challenge that it is compatible with different frame rate variations and different shutter operations, and has the ability to mitigate the rolling effect as well as the rotating effect while effectively minimizing transmission overhead. Practical implementations are demonstrated and a performance comparison is presented.

  11. Potential Cost Savings with 3D Printing Combined With 3D Imaging and CPLM for Fleet Maintenance and Revitalization

    Science.gov (United States)

    2014-05-01

    1 Potential Cost Savings with 3D Printing Combined With 3D Imaging and CPLM for Fleet Maintenance and Revitalization David N. Ford...2014 4. TITLE AND SUBTITLE Potential Cost Savings with 3D Printing Combined With 3D Imaging and CPLM for Fleet Maintenance and Revitalization 5a...Manufacturing ( 3D printing ) 2 Research Context Problem: Learning curve savings forecasted in SHIPMAIN maintenance initiative have not materialized

  12. Multifractal and Singularity Maps of soil surface moisture distribution derived from 2D image analysis.

    Science.gov (United States)

    Cumbrera, Ramiro; Millán, Humberto; Martín-Sotoca, Juan Jose; Pérez Soto, Luis; Sanchez, Maria Elena; Tarquis, Ana Maria

    2016-04-01

    methods for mapping geochemical anomalies caused by buried sources and for predicting undiscovered mineral deposits in covered areas. Journal of Geochemical Exploration, 122, 55-70. Cumbrera, R., Ana M. Tarquis, Gabriel Gascó, Humberto Millán (2012) Fractal scaling of apparent soil moisture estimated from vertical planes of Vertisol pit images. Journal of Hydrology (452-453), 205-212. Martin Sotoca; J.J. Antonio Saa-Requejo, Juan Grau and Ana M. Tarquis (2016). Segmentation of singularity maps in the context of soil porosity. Geophysical Research Abstracts, 18, EGU2016-11402. Millán, H., Cumbrera, R. and Ana M. Tarquis (2016) Multifractal and Levy-stable statistics of soil surface moisture distribution derived from 2D image analysis. Applied Mathematical Modelling, 40(3), 2384-2395.

  13. A filtering approach to image reconstruction in 3D SPECT

    International Nuclear Information System (INIS)

    Bronnikov, Andrei V.

    2000-01-01

    We present a new approach to three-dimensional (3D) image reconstruction using analytical inversion of the exponential divergent beam transform, which can serve as a mathematical model for cone-beam 3D SPECT imaging. We apply a circular cone-beam scan and assume constant attenuation inside a convex area with a known boundary, which is satisfactory in brain imaging. The reconstruction problem is reduced to an image restoration problem characterized by a shift-variant point spread function which is given analytically. The method requires two computation steps: backprojection and filtering. The modulation transfer function (MTF) of the filter is derived by means of an original methodology using the 2D Laplace transform. The filter is implemented in the frequency domain and requires 2D Fourier transform of transverse slices. In order to obtain a shift-invariant cone-beam projection-backprojection operator we resort to an approximation, assuming that the collimator has a relatively large focal length. Nevertheless, numerical experiments demonstrate surprisingly good results for detectors with relatively short focal lengths. The use of a wavelet-based filtering algorithm greatly improves the stability to Poisson noise. (author)

  14. Minimally invasive vascular imaging using 3D-CTA and 3D-MRA. Update

    International Nuclear Information System (INIS)

    Hayashi, Hiromitsu; Kawamata, Hiroshi; Takagi, Ryo; Amano, Yasuo; Wakabayashi, Hiroyuki; Ichikawa, Kazuo; Kumazaki, Tatsuo

    1998-01-01

    Conventional angiography is considered the standard of reference for diagnostic imaging of vascular diseases with respect to its temporal and spatial resolution. This procedure, however is invasive and repeated studies are difficult, and arterial complications are occasionally associated in catheter-based conventional angiography. Recent advances in diagnostic imaging have facilitated three-dimensional CT angiography (3D-CTA) using the volumetric acquisition capabilities inherent in spiral CT and three-dimensional MR angiography (3D-MRA) using the 3D gradient-echo sequence with a bolus injection of Gd-DTPA. These techniques can provide vascular images exceedingly similar to conventional angiograms within a short acquisition time. 3D-CTA and 3D-MRA are considered to be promising, minimally invasive methods for obtaining images of the vasculature, and alternatives to catheter angiography. This study reviews the current status of 3D-CTA and 3D-MRA, with emphasis on the clinical usefulness of three-dimensional diagnostic imaging for the evaluation of diverse vascular pathologies. (author)

  15. (/sup 76/Br)Bromolisuride: a new tool for quantitative in vivo imaging of D-2 dopamine receptors

    Energy Technology Data Exchange (ETDEWEB)

    Maziere, B; Loc' h, C; Stulzaft, O; Ottaviani, M; Comar, D; Maziere, M; Hantraye, P

    1986-08-15

    Bromolisuride, an ergoline derivative, was labeled with the positron emitter radionuclide, bromine 76. In vitro and in vivo binding and competition studies in rats demonstrated a high affinity (K/sub D/ = 0.3 nM) and a high specificity of this new radioligand for D-2 dopamine receptors. PET kinetic studies in baboons showed an accumulation of (/sup 76/Br)bromolisuride in the striatum which reached a maximum 30 min post-injection and which could be displaced by haloperidol. All these results indicated that this new ligand is certainly suitable for the non-invasive in vivo quantitative imaging of D-2 dopamine receptor sites in human brain. 20 refs.; 6 figs.; 1 table.

  16. Projection-slice theorem based 2D-3D registration

    Science.gov (United States)

    van der Bom, M. J.; Pluim, J. P. W.; Homan, R.; Timmer, J.; Bartels, L. W.

    2007-03-01

    In X-ray guided procedures, the surgeon or interventionalist is dependent on his or her knowledge of the patient's specific anatomy and the projection images acquired during the procedure by a rotational X-ray source. Unfortunately, these X-ray projections fail to give information on the patient's anatomy in the dimension along the projection axis. It would be very profitable to provide the surgeon or interventionalist with a 3D insight of the patient's anatomy that is directly linked to the X-ray images acquired during the procedure. In this paper we present a new robust 2D-3D registration method based on the Projection-Slice Theorem. This theorem gives us a relation between the pre-operative 3D data set and the interventional projection images. Registration is performed by minimizing a translation invariant similarity measure that is applied to the Fourier transforms of the images. The method was tested by performing multiple exhaustive searches on phantom data of the Circle of Willis and on a post-mortem human skull. Validation was performed visually by comparing the test projections to the ones that corresponded to the minimal value of the similarity measure. The Projection-Slice Theorem Based method was shown to be very effective and robust, and provides capture ranges up to 62 degrees. Experiments have shown that the method is capable of retrieving similar results when translations are applied to the projection images.

  17. Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

    International Nuclear Information System (INIS)

    Pauzi, Nur Farahana; Majid, Zafri Azran Abdul; Sapuan, Abdul Halim; Junet, Laila Kalidah; Azemin, Mohd Zulfaezal Che

    2015-01-01

    Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner

  18. Multiparameter double hole contrast detail phantom: Ability to detect image displacement due to off position anode stem

    Energy Technology Data Exchange (ETDEWEB)

    Pauzi, Nur Farahana; Majid, Zafri Azran Abdul; Sapuan, Abdul Halim; Junet, Laila Kalidah [Department of Diagnostic Imaging and Radiotherapy, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Jalan Istana, 25200, Kuantan, Pahang (Malaysia); Azemin, Mohd Zulfaezal Che [Department of Optometry and Visual Science, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Jalan Istana, 25200, Kuantan, Pahang (Malaysia)

    2015-04-24

    Contrast Detail phantom is a quality control tool to analyze the performance of imaging devices. Currently, its function is solely to evaluate the contrast detail characteristic of imaging system. It consists of drilled hole which gives effect to the penetration of x-ray beam divergence to pass through the base of each hole. This effect will lead to false appearance of image from its original location but it does not being visualized in the radiograph. In this study, a new design of Contrast Detail phantom’s hole which consists of double hole construction has been developed. It can detect the image displacement which is due to off position of anode stem from its original location. The double hole differs from previous milled hole, whereby it consists of combination of different hole diameters. Small hole diameter (3 mm) is positioned on top of larger hole diameter (10 mm). The thickness of double hole acrylic blocks is 13 mm. Result revealed that Multiparameter Double Hole Contrast Detail phantom can visualize the shifted flaw image quality produced by x-ray machine due to improper position of the anode stem which is attached to rotor and stator. The effective focal spot of x-ray beam also has been shifted from the center of collimator as a result of off-position anode stem. As a conclusion, the new design of double hole Contrast Detail phantom able to measure those parameters in a well manner.

  19. 3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models

    International Nuclear Information System (INIS)

    Dhou, S; Hurwitz, M; Cai, W; Rottmann, J; Williams, C; Wagar, M; Berbeco, R; Lewis, J H; Mishra, P; Li, R; Ionascu, D

    2015-01-01

    3D fluoroscopic images represent volumetric patient anatomy during treatment with high spatial and temporal resolution. 3D fluoroscopic images estimated using motion models built using 4DCT images, taken days or weeks prior to treatment, do not reliably represent patient anatomy during treatment. In this study we developed and performed initial evaluation of techniques to develop patient-specific motion models from 4D cone-beam CT (4DCBCT) images, taken immediately before treatment, and used these models to estimate 3D fluoroscopic images based on 2D kV projections captured during treatment. We evaluate the accuracy of 3D fluoroscopic images by comparison to ground truth digital and physical phantom images. The performance of 4DCBCT-based and 4DCT-based motion models are compared in simulated clinical situations representing tumor baseline shift or initial patient positioning errors. The results of this study demonstrate the ability for 4DCBCT imaging to generate motion models that can account for changes that cannot be accounted for with 4DCT-based motion models. When simulating tumor baseline shift and patient positioning errors of up to 5 mm, the average tumor localization error and the 95th percentile error in six datasets were 1.20 and 2.2 mm, respectively, for 4DCBCT-based motion models. 4DCT-based motion models applied to the same six datasets resulted in average tumor localization error and the 95th percentile error of 4.18 and 5.4 mm, respectively. Analysis of voxel-wise intensity differences was also conducted for all experiments. In summary, this study demonstrates the feasibility of 4DCBCT-based 3D fluoroscopic image generation in digital and physical phantoms and shows the potential advantage of 4DCBCT-based 3D fluoroscopic image estimation when there are changes in anatomy between the time of 4DCT imaging and the time of treatment delivery. (paper)

  20. a Circleless "2D/3D Total STATION": a Low Cost Instrument for Surveying, Recording Point Clouds, Documentation, Image Acquisition and Visualisation

    Science.gov (United States)

    Scherer, M.

    2013-07-01

    Hardware and software of the universally applicable instrument - referred to as a 2D/3D total station - are described here, as well as its practical use. At its core it consists of a 3D camera - often also called a ToF camera, a pmd camera or a RIM-camera - combined with a common industrial 2D camera. The cameras are rigidly coupled with their optical axes in parallel. A new type of instrument was created mounting this 2D/3D system on a tripod in a specific way. Because of it sharing certain characteristics with a total station and a tacheometer, respectively, the new device was called a 2D/3D total station. It may effectively replace a common total station or a laser scanner in some respects. After a brief overview of the prototype's features this paper then focuses on the methodological characteristics for practical application. Its usability as a universally applicable stand-alone instrument is demonstrated for surveying, recording RGB-coloured point clouds as well as delivering images for documentation and visualisation. Because of its limited range (10m without reflector and 150 m to reflector prisms) and low range accuracy (ca. 2 cm to 3 cm) compared to present-day total stations and laser scanners, the practical usage of the 2D/3D total station is currently limited to acquisition of accidents, forensic purpuses, speleology or facility management, as well as architectural recordings with low requirements regarding accuracy. However, the author is convinced that in the near future advancements in 3D camera technology will allow this type of comparatively low cost instrument to replace the total station as well as the laser scanner in an increasing number of areas.

  1. Usefulness of the classification technique of cerebral artery for 2D/3D registration

    International Nuclear Information System (INIS)

    Takemura, Akihiro; Suzuki, Masayuki; Kikuchi, Yuzo; Okumura, Yusuke; Harauchi, Hajime

    2007-01-01

    Several papers have proposed 2D/3D registration methods of the cerebral artery using magnetic resonance angiography (MRA) and digital subtraction angiography (DSA). Since differences between vessels in a DSA image and MRA volume data cause registration failure, we previously proposed a method to extract vessels from MRA volume data using a technique based on classification of the cerebral artery. In this paper, we evaluated the usefulness of this classification technique by evaluating the reliability of this 2D/3D registration method. This classification method divides the cerebral artery in MRA volume data into 12 segments. According to the results of the classification, structures corresponding to vessels on a DSA image can then be extracted. We applied the 2D/3D registration with/without classification to 16 pairs of MRA volume data and DSA images obtained from six patients. The registration results were scored into four levels (Excellent, Good, Fair and Poor). The rates of successful registration (>fair) were 37.5% for registration without classification and 81.3% for that with classification. These findings suggested that there was a low percentage of incorrectly extracted voxels and we could facilitate reliable registration. Thus, the classification technique was shown to be useful for feature-based 2D/3D registration. (author)

  2. Interactive initialization of 2D/3D rigid registration

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Ren Hui; Güler, Özgür [The Sheikh Zayed Institute for Pediatric Surgical Innovation, Children' s National Medical Center, Washington, DC 20010 (United States); Kürklüoglu, Mustafa [Department of Cardiac Surgery, Children' s National Medical Center, Washington, DC 20010 (United States); Lovejoy, John [Department of Orthopaedic Surgery and Sports Medicine, Children' s National Medical Center, Washington, DC 20010 (United States); Yaniv, Ziv, E-mail: ZYaniv@childrensnational.org [The Sheikh Zayed Institute for Pediatric Surgical Innovation, Children' s National Medical Center, Washington, DC 20010 and Departments of Pediatrics and Radiology, George Washington University, Washington, DC 20037 (United States)

    2013-12-15

    Purpose: Registration is one of the key technical components in an image-guided navigation system. A large number of 2D/3D registration algorithms have been previously proposed, but have not been able to transition into clinical practice. The authors identify the primary reason for the lack of adoption with the prerequisite for a sufficiently accurate initial transformation, mean target registration error of about 10 mm or less. In this paper, the authors present two interactive initialization approaches that provide the desired accuracy for x-ray/MR and x-ray/CT registration in the operating room setting. Methods: The authors have developed two interactive registration methods based on visual alignment of a preoperative image, MR, or CT to intraoperative x-rays. In the first approach, the operator uses a gesture based interface to align a volume rendering of the preoperative image to multiple x-rays. The second approach uses a tracked tool available as part of a navigation system. Preoperatively, a virtual replica of the tool is positioned next to the anatomical structures visible in the volumetric data. Intraoperatively, the physical tool is positioned in a similar manner and subsequently used to align a volume rendering to the x-ray images using an augmented reality (AR) approach. Both methods were assessed using three publicly available reference data sets for 2D/3D registration evaluation. Results: In the authors' experiments, the authors show that for x-ray/MR registration, the gesture based method resulted in a mean target registration error (mTRE) of 9.3 ± 5.0 mm with an average interaction time of 146.3 ± 73.0 s, and the AR-based method had mTREs of 7.2 ± 3.2 mm with interaction times of 44 ± 32 s. For x-ray/CT registration, the gesture based method resulted in a mTRE of 7.4 ± 5.0 mm with an average interaction time of 132.1 ± 66.4 s, and the AR-based method had mTREs of 8.3 ± 5.0 mm with interaction times of 58 ± 52 s. Conclusions: Based on

  3. Interactive initialization of 2D/3D rigid registration

    International Nuclear Information System (INIS)

    Gong, Ren Hui; Güler, Özgür; Kürklüoglu, Mustafa; Lovejoy, John; Yaniv, Ziv

    2013-01-01

    Purpose: Registration is one of the key technical components in an image-guided navigation system. A large number of 2D/3D registration algorithms have been previously proposed, but have not been able to transition into clinical practice. The authors identify the primary reason for the lack of adoption with the prerequisite for a sufficiently accurate initial transformation, mean target registration error of about 10 mm or less. In this paper, the authors present two interactive initialization approaches that provide the desired accuracy for x-ray/MR and x-ray/CT registration in the operating room setting. Methods: The authors have developed two interactive registration methods based on visual alignment of a preoperative image, MR, or CT to intraoperative x-rays. In the first approach, the operator uses a gesture based interface to align a volume rendering of the preoperative image to multiple x-rays. The second approach uses a tracked tool available as part of a navigation system. Preoperatively, a virtual replica of the tool is positioned next to the anatomical structures visible in the volumetric data. Intraoperatively, the physical tool is positioned in a similar manner and subsequently used to align a volume rendering to the x-ray images using an augmented reality (AR) approach. Both methods were assessed using three publicly available reference data sets for 2D/3D registration evaluation. Results: In the authors' experiments, the authors show that for x-ray/MR registration, the gesture based method resulted in a mean target registration error (mTRE) of 9.3 ± 5.0 mm with an average interaction time of 146.3 ± 73.0 s, and the AR-based method had mTREs of 7.2 ± 3.2 mm with interaction times of 44 ± 32 s. For x-ray/CT registration, the gesture based method resulted in a mTRE of 7.4 ± 5.0 mm with an average interaction time of 132.1 ± 66.4 s, and the AR-based method had mTREs of 8.3 ± 5.0 mm with interaction times of 58 ± 52 s. Conclusions: Based on the

  4. A comparison of porosity analysis using 2D stereology estimates and 3D serial sectioning for additively manufactured Ti 6Al 2Sn 4Zr 2Mo alloy

    International Nuclear Information System (INIS)

    Ganti, Satya R.; Velez, Michael A.; Geier, Brian A.; Hayes, Brian J.; Turner, Bryan J.; Jenkins, Elizabeth J.

    2017-01-01

    Porosity is a typical defect in additively manufactured (AM) parts. Such defects limit the properties and performance of AM parts, and therefore need to be characterized accurately. Current methods for characterization of defects and microstructure rely on classical stereological methods that extrapolate information from two dimensional images. The automation of serial sectioning provides an opportunity to precisely and accurately quantify porosity in three dimensions in materials. In this work, we analyzed the porosity of an additively manufactured Ti 6Al 2Sn 4Zr 2Mo sample using Robo-Met.3D "r"e"g"i"s"t"e"r"e"d, an automated serial sectioning system. Image processing for three dimensional reconstruction of the serial-sectioned two dimensional images was performed using open source image analysis software (Fiji/ImageJ, Dream.3D, Paraview). The results from this 3D serial sectioning analysis were then compared to classical 2D stereological methods (Saltykov stereological theory). We found that for this dataset, the classical 2D methods underestimated the porosity size and distributions of the larger pores; a critical attribute to fatigue behavior of the AM part. The results suggest that acquiring experimental data with equipment such as Robo-Met.3D "r"e"g"i"s"t"e"r"e"d to measure the number and size of particles such as pores in a volume irrespective of knowing their shape is a better choice.

  5. Construction of static 3D ultrasonography image by radiation beam tracking method from 1D array probe

    Energy Technology Data Exchange (ETDEWEB)

    Doh, Il; Kim, Yong Tae; Ahn, Bong Young [Center for Medical Metrology, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Kim, Kwang Youn [Meta biomed Co.,Ltd, Cheongju (Korea, Republic of)

    2015-04-15

    This paper describes the construction of a static 3D ultrasonography image by tracking the radiation beam position during the handy operation of a 1D array probe to enable point-of-care use. The theoretical model of the transformation from the translational and rotational information of the sensor mounted on the probe to the reference Cartesian coordinate system was given. The signal amplification and serial communication interface module was made using a commercially available sensor. A test phantom was also made using silicone putty in a donut shape. During the movement of the hand-held probe, B-mode movie and sensor signals were recorded. B-mode images were periodically selected from the movie, and the gray levels of the pixels for each image were converted to the gray levels of 3D voxels. 3D and 2D images of arbitrary cross-section of the B-mode type were also constructed from the voxel data, and agreed well with the shape of the test phantom.

  6. Evaluation of grades 3 and 4 chondromalacia of the knee using T2*-weighted 3D gradient-echo articular cartilage imaging.

    Science.gov (United States)

    Murphy, B J

    2001-06-01

    To determine the accuracy of T2*-weighted three-dimensional (3D) gradient-echo articular cartilage imaging in the identification of grades 3 and 4 chondromalacia of the knee. A retrospective evaluation of 80 patients who underwent both arthroscopic and MRI evaluation was performed. The 3D images were interpreted by one observer without knowledge of the surgical results. The medial and lateral femoral condyles, the medial and lateral tibial plateau, the patellar cartilage and trochlear groove were evaluated. MR cartilage images were considered positive if focal reduction of cartilage thickness was present (grade 3 chondromalacia) or if complete loss of cartilage was present (grade 4 chondromalacia). Comparison of the 3D MR results with the arthroscopic findings was performed. Eighty patients were included in the study group. A total of 480 articular cartilage sites were evaluated with MRI and arthroscopy. Results of MR identification of grades 3 and 4 chondromalacia, all sites combined, were: sensitivity 83%, specificity 97%, false negative rate 17%, false positive rate 3%, positive predictive value 87%, negative predictive value 95%, overall accuracy 93%. The results demonstrate that T2*-weighted 3D gradient-echo articular cartilage imaging can identify grades 3 and 4 chondromalacia of the knee.

  7. Evaluation of grades 3 and 4 chondromalacia of the knee using T2*-weighted 3D gradient-echo articular cartilage imaging

    International Nuclear Information System (INIS)

    Murphy, B.J.

    2001-01-01

    Objective. To determine the accuracy of T2*-weighted three-dimensional (3D) gradient-echo articular cartilage imaging in the identification of grades 3 and 4 chondromalacia of the knee.Design and patients. A retrospective evaluation of 80 patients who underwent both arthroscopic and MRI evaluation was performed. The 3D images were interpreted by one observer without knowledge of the surgical results. The medial and lateral femoral condyles, the medial and lateral tibial plateau, the patellar cartilage and trochlear groove were evaluated. MR cartilage images were considered positive if focal reduction of cartilage thickness was present (grade 3 chondromalacia) or if complete loss of cartilage was present (grade 4 chondromalacia). Comparison of the 3D MR results with the arthroscopic findings was performed.Results. Eighty patients were included in the study group. A total of 480 articular cartilage sites were evaluated with MRI and arthroscopy. Results of MR identification of grades 3 and 4 chondromalacia, all sites combined, were: sensitivity 83%, specificity 97%, false negative rate 17%, false positive rate 3%, positive predictive value 87%, negative predictive value 95%, overall accuracy 93%.Conclusion. The results demonstrate that T2*-weighted 3D gradient-echo articular cartilage imaging can identify grades 3 and 4 chondromalacia of the knee. (orig.)

  8. Evaluation of grades 3 and 4 chondromalacia of the knee using T2*-weighted 3D gradient-echo articular cartilage imaging

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, B.J. [Dept. of Radiology, Univ. of Miami School of Medicine, FL (United States)

    2001-06-01

    Objective. To determine the accuracy of T2*-weighted three-dimensional (3D) gradient-echo articular cartilage imaging in the identification of grades 3 and 4 chondromalacia of the knee.Design and patients. A retrospective evaluation of 80 patients who underwent both arthroscopic and MRI evaluation was performed. The 3D images were interpreted by one observer without knowledge of the surgical results. The medial and lateral femoral condyles, the medial and lateral tibial plateau, the patellar cartilage and trochlear groove were evaluated. MR cartilage images were considered positive if focal reduction of cartilage thickness was present (grade 3 chondromalacia) or if complete loss of cartilage was present (grade 4 chondromalacia). Comparison of the 3D MR results with the arthroscopic findings was performed.Results. Eighty patients were included in the study group. A total of 480 articular cartilage sites were evaluated with MRI and arthroscopy. Results of MR identification of grades 3 and 4 chondromalacia, all sites combined, were: sensitivity 83%, specificity 97%, false negative rate 17%, false positive rate 3%, positive predictive value 87%, negative predictive value 95%, overall accuracy 93%.Conclusion. The results demonstrate that T2*-weighted 3D gradient-echo articular cartilage imaging can identify grades 3 and 4 chondromalacia of the knee. (orig.)

  9. Flibe-D2 Permeation Experiment and Analysis

    International Nuclear Information System (INIS)

    Fukada, S.; Anderl, R.A.; Pawelko, R.J.; Smolik, G.R.; Schuetz, S.T.; O'Brien, J.E.; Nishimura, H.; Hatano, Y.; Terai, T.; Petti, D.A.; Sze, D.-K.; Tanaka, S.

    2003-01-01

    Experiment of D 2 permeation through Ni facing with purified Flibe is being carried out under the Japan-US joint research project (JUPITER-II). The experiment is proceeding in the following phases; (i) fabrication and assembly of a dual-probe permeation apparatus, (ii) a single-probe Ni/D 2 permeation experiment without Flibe, (iii) a dual-probe Ni/D 2 permeation experiment without Flibe, (iv) Flibe chemical purification by HF/H 2 gas bubbling, (v) physical purification by Flibe transport through a porous Ni filter, (vi) Ni/Flibe/D 2 permeation experiment, and (vii) Ni/Flibe/HT permeation experiment. The present paper describes results of the single and dual Ni/D 2 permeation experiments in detail

  10. A procedure for the evaluation of 2D radiographic texture analysis to assess 3D bone micro-architecture; Evaluation de l'analyse de la texture de radiographies 2D pour evaluer les micro architecture 3D d'os

    Energy Technology Data Exchange (ETDEWEB)

    Apostol, L.; Peyrin, F.; Yot, S.; Basset, O.; Odet, Ch. [CREATIS - Centre National de la Recherche Scientifique (UMR CNRS 5515), 69 - Villeurbanne (France); Apostal, L.; Boller, E. [European Synchrotron Radiation Facility (ESRF), 38 - Grenoble (France); Tabary, J.; Dinten, J.M. [CEA Grenoble, Lab. d' Electronique et de Technologie de l' Informatique (LETI), 38 (France); Boudousq, V.; Kotzki, P.O. [Faculte de Medecine, Lab. de Biophysique Medicale, 30 - Nimes (France)

    2004-07-01

    Although the diagnosis of osteoporosis is mainly based on Dual X-ray Absorptiometry, it has been shown that trabecular bone micro-architecture is also an important factor in regards of fracture risk, which can be efficiently assessed in vitro using three-dimensional x-ray microtomography ({mu}CT). In vivo, techniques based on high-resolution x-ray radiography associated to texture analysis have been proposed to investigate bone micro-architecture, but their relevance for giving pertinent 3D information is unclear. The purpose of this work was to develop a method for evaluating the relationships between 3D micro-architecture and 2D texture parameters, and optimizing the conditions for radiographic imaging. Bone sample images taken from cortical to cortical were acquired using 3D-synchrotron x-ray {mu}CT at the ESRF. The 3D digital images were further used for two purposes: 1) quantification of three-dimensional bone micro-architecture, 2) simulation of realistic x-ray radiographs under different acquisition conditions. Texture analysis was then applied to these 2D radiographs using a large variety of methods (co-occurrence, spectrum, fractal...). First results of the statistical analysis between 2D and 3D parameters allowed identifying the most relevant 2D texture parameters. (authors)

  11. Gen-2 Hand-Held Optical Imager towards Cancer Imaging: Reflectance and Transillumination Phantom Studies

    Directory of Open Access Journals (Sweden)

    Anuradha Godavarty

    2012-02-01

    Full Text Available Hand-held near-infrared (NIR optical imagers are developed by various researchers towards non-invasive clinical breast imaging. Unlike these existing imagers that can perform only reflectance imaging, a generation-2 (Gen-2 hand-held optical imager has been recently developed to perform both reflectance and transillumination imaging. The unique forked design of the hand-held probe head(s allows for reflectance imaging (as in ultrasound and transillumination or compressed imaging (as in X-ray mammography. Phantom studies were performed to demonstrate two-dimensional (2D target detection via reflectance and transillumination imaging at various target depths (1–5 cm deep and using simultaneous multiple point illumination approach. It was observed that 0.45 cc targets were detected up to 5 cm deep during transillumination, but limited to 2.5 cm deep during reflectance imaging. Additionally, implementing appropriate data post-processing techniques along with a polynomial fitting approach, to plot 2D surface contours of the detected signal, yields distinct target detectability and localization. The ability of the gen-2 imager to perform both reflectance and transillumination imaging allows its direct comparison to ultrasound and X-ray mammography results, respectively, in future clinical breast imaging studies.

  12. Soil Structure Evaluation Across Geologic Transition Zones Using 2D Electrical Resistivity Imaging Technique

    Directory of Open Access Journals (Sweden)

    Geraldine C Anukwu

    2017-06-01

    Full Text Available This study utilizes the electrical resistivity values obtained using 2-D Electrical resistivity imaging (ERI technique to evaluate the subsurface lithology across different geological units. The primary objective was to determine the effect of subsurface lithology on the integrity of a road pavement, which had developed cracks and potholes at various locations. The dipole-dipole configuration was utilized and a total of nine traverses were established in the study area, whose geology cuts across both the basement and sedimentary complexes. The inverted resistivity section obtained showed significant variation in resistivity along established traverses and also across the different rock units, with the resistivity value ranging from about 4 ohm-m to greater than 7000 ohm- m. The lithology as interpreted from the resistivity section revealed the presence topsoil, clay, sandy clay, sand, sand stones/basement rocks, with varying vertical and horizontal arrangements to a depth of 40m. Results suggest that the geologic sequence and structure might have contributed to the observed pavement failure. The capability of the 2D ERI as an imaging tool is observed, especially across the transition zones as depicted in this study. The study further stressed the ability of this technique if properly designed and implemented, to be capable of providing a wealth of information that could complement other traditional geotechnical and geologic techniques.

  13. Object classfication from RGB-D images using depth context kernel descriptors

    DEFF Research Database (Denmark)

    Pan, Hong; Olsen, Søren Ingvor; Zhu, Yaping

    2015-01-01

    Context cue is important in object classification. By embedding the depth context cue of image attributes into kernel descriptors, we propose a new set of depth image descriptors called depth context kernel descriptors (DCKD) for RGB-D based object classification. The motivation of DCKD is to use...... the depth consistency of image attributes defined within a neighboring region to improve the robustness of descriptor matching in the kernel space. Moreover, a novel joint spatial-depth pooling (JSDP) scheme, which further partitions image sub-regions using the depth cue and pools features in both 2D image...

  14. 3D imaging by serial block face scanning electron microscopy for materials science using ultramicrotomy.

    Science.gov (United States)

    Hashimoto, Teruo; Thompson, George E; Zhou, Xiaorong; Withers, Philip J

    2016-04-01

    Mechanical serial block face scanning electron microscopy (SBFSEM) has emerged as a means of obtaining three dimensional (3D) electron images over volumes much larger than possible by focused ion beam (FIB) serial sectioning and at higher spatial resolution than achievable with conventional X-ray computed tomography (CT). Such high resolution 3D electron images can be employed for precisely determining the shape, volume fraction, distribution and connectivity of important microstructural features. While soft (fixed or frozen) biological samples are particularly well suited for nanoscale sectioning using an ultramicrotome, the technique can also produce excellent 3D images at electron microscope resolution in a time and resource-efficient manner for engineering materials. Currently, a lack of appreciation of the capabilities of ultramicrotomy and the operational challenges associated with minimising artefacts for different materials is limiting its wider application to engineering materials. Consequently, this paper outlines the current state of the art for SBFSEM examining in detail how damage is introduced during slicing and highlighting strategies for minimising such damage. A particular focus of the study is the acquisition of 3D images for a variety of metallic and coated systems. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  15. Hybrid 3D pregnant woman and fetus modeling from medical imaging for dosimetry studies

    Energy Technology Data Exchange (ETDEWEB)

    Bibin, Lazar; Anquez, Jeremie; Angelini, Elsa; Bloch, Isabelle [Telecom ParisTech, CNRS UMR 5141 LTCI, Institut TELECOM, Paris (France)

    2010-01-15

    Numerical simulations studying the interactions between radiations and biological tissues require the use of three-dimensional models of the human anatomy at various ages and in various positions. Several detailed and flexible models exist for adults and children and have been extensively used for dosimetry. On the other hand, progress of simulation studies focusing on pregnant women and the fetus have been limited by the fact that only a small number of models exist with rather coarse anatomical details and a poor representation of the anatomical variability of the fetus shape and its position over the entire gestation. In this paper, we propose a new computational framework to generate 3D hybrid models of pregnant women, composed of fetus shapes segmented from medical images and a generic maternal body envelope representing a synthetic woman scaled to the dimension of the uterus. The computational framework includes the following tasks: image segmentation, contour regularization, mesh-based surface reconstruction, and model integration. A series of models was created to represent pregnant women at different gestational stages and with the fetus in different positions, all including detailed tissues of the fetus and the utero-fetal unit, which play an important role in dosimetry. These models were anatomically validated by clinical obstetricians and radiologists who verified the accuracy and representativeness of the anatomical details, and the positioning of the fetus inside the maternal body. The computational framework enables the creation of detailed, realistic, and representative fetus models from medical images, directly exploitable for dosimetry simulations. (orig.)

  16. Hybrid 3D pregnant woman and fetus modeling from medical imaging for dosimetry studies

    International Nuclear Information System (INIS)

    Bibin, Lazar; Anquez, Jeremie; Angelini, Elsa; Bloch, Isabelle

    2010-01-01

    Numerical simulations studying the interactions between radiations and biological tissues require the use of three-dimensional models of the human anatomy at various ages and in various positions. Several detailed and flexible models exist for adults and children and have been extensively used for dosimetry. On the other hand, progress of simulation studies focusing on pregnant women and the fetus have been limited by the fact that only a small number of models exist with rather coarse anatomical details and a poor representation of the anatomical variability of the fetus shape and its position over the entire gestation. In this paper, we propose a new computational framework to generate 3D hybrid models of pregnant women, composed of fetus shapes segmented from medical images and a generic maternal body envelope representing a synthetic woman scaled to the dimension of the uterus. The computational framework includes the following tasks: image segmentation, contour regularization, mesh-based surface reconstruction, and model integration. A series of models was created to represent pregnant women at different gestational stages and with the fetus in different positions, all including detailed tissues of the fetus and the utero-fetal unit, which play an important role in dosimetry. These models were anatomically validated by clinical obstetricians and radiologists who verified the accuracy and representativeness of the anatomical details, and the positioning of the fetus inside the maternal body. The computational framework enables the creation of detailed, realistic, and representative fetus models from medical images, directly exploitable for dosimetry simulations. (orig.)

  17. Fast multi-core based multimodal registration of 2D cross-sections and 3D datasets.

    Science.gov (United States)

    Scharfe, Michael; Pielot, Rainer; Schreiber, Falk

    2010-01-11

    Solving bioinformatics tasks often requires extensive computational power. Recent trends in processor architecture combine multiple cores into a single chip to improve overall performance. The Cell Broadband Engine (CBE), a heterogeneous multi-core processor, provides power-efficient and cost-effective high-performance computing. One application area is image analysis and visualisation, in particular registration of 2D cross-sections into 3D image datasets. Such techniques can be used to put different image modalities into spatial correspondence, for example, 2D images of histological cuts into morphological 3D frameworks. We evaluate the CBE-driven PlayStation 3 as a high performance, cost-effective computing platform by adapting a multimodal alignment procedure to several characteristic hardware properties. The optimisations are based on partitioning, vectorisation, branch reducing and loop unrolling techniques with special attention to 32-bit multiplies and limited local storage on the computing units. We show how a typical image analysis and visualisation problem, the multimodal registration of 2D cross-sections and 3D datasets, benefits from the multi-core based implementation of the alignment algorithm. We discuss several CBE-based optimisation methods and compare our results to standard solutions. More information and the source code are available from http://cbe.ipk-gatersleben.de. The results demonstrate that the CBE processor in a PlayStation 3 accelerates computational intensive multimodal registration, which is of great importance in biological/medical image processing. The PlayStation 3 as a low cost CBE-based platform offers an efficient option to conventional hardware to solve computational problems in image processing and bioinformatics.

  18. A framework for automatic creation of gold-standard rigid 3D-2D registration datasets.

    Science.gov (United States)

    Madan, Hennadii; Pernuš, Franjo; Likar, Boštjan; Špiclin, Žiga

    2017-02-01

    Advanced image-guided medical procedures incorporate 2D intra-interventional information into pre-interventional 3D image and plan of the procedure through 3D/2D image registration (32R). To enter clinical use, and even for publication purposes, novel and existing 32R methods have to be rigorously validated. The performance of a 32R method can be estimated by comparing it to an accurate reference or gold standard method (usually based on fiducial markers) on the same set of images (gold standard dataset). Objective validation and comparison of methods are possible only if evaluation methodology is standardized, and the gold standard  dataset is made publicly available. Currently, very few such datasets exist and only one contains images of multiple patients acquired during a procedure. To encourage the creation of gold standard 32R datasets, we propose an automatic framework. The framework is based on rigid registration of fiducial markers. The main novelty is spatial grouping of fiducial markers on the carrier device, which enables automatic marker localization and identification across the 3D and 2D images. The proposed framework was demonstrated on clinical angiograms of 20 patients. Rigid 32R computed by the framework was more accurate than that obtained manually, with the respective target registration error below 0.027 mm compared to 0.040 mm. The framework is applicable for gold standard setup on any rigid anatomy, provided that the acquired images contain spatially grouped fiducial markers. The gold standard datasets and software will be made publicly available.

  19. Light field morphing using 2D features.

    Science.gov (United States)

    Wang, Lifeng; Lin, Stephen; Lee, Seungyong; Guo, Baining; Shum, Heung-Yeung

    2005-01-01

    We present a 2D feature-based technique for morphing 3D objects represented by light fields. Existing light field morphing methods require the user to specify corresponding 3D feature elements to guide morph computation. Since slight errors in 3D specification can lead to significant morphing artifacts, we propose a scheme based on 2D feature elements that is less sensitive to imprecise marking of features. First, 2D features are specified by the user in a number of key views in the source and target light fields. Then the two light fields are warped view by view as guided by the corresponding 2D features. Finally, the two warped light fields are blended together to yield the desired light field morph. Two key issues in light field morphing are feature specification and warping of light field rays. For feature specification, we introduce a user interface for delineating 2D features in key views of a light field, which are automatically interpolated to other views. For ray warping, we describe a 2D technique that accounts for visibility changes and present a comparison to the ideal morphing of light fields. Light field morphing based on 2D features makes it simple to incorporate previous image morphing techniques such as nonuniform blending, as well as to morph between an image and a light field.

  20. Ring artifacts removal from synchrotron CT image slices

    International Nuclear Information System (INIS)

    Wei Zhouping; Chapman, Dean; Wiebe, Sheldon

    2013-01-01

    Ring artifacts can occur in reconstructed images from x-ray Computerized Tomography (CT) as full or partial concentric rings superimposed on the scanned structures. Due to the data corruption by those ring artifacts in CT images, qualitative and quantitative analysis of these images are compromised. In this paper, we propose to correct the ring artifacts on the reconstructed synchrotron radiation (SR) CT image slices. The proposed correction procedure includes the following steps: (1). transform the reconstructed CT images into polar coordinates; (2) apply discrete two-dimensional (2D) wavelet transform to the polar image to decompose it into four image components: low pass band image component, as well as the components from horizontal, vertical and diagonal details bands; (3). apply 2D Fourier transform to the vertical details band image component only, since the ring artifacts become vertical lines in the polar coordinates; (4). apply Gaussian filtering in Fourier domain along the abscissa direction to suppress the vertical lines, since the information of the vertical lines in Fourier domain is completely condensed to that direction; (5). perform inverse Fourier transform to get the corrected vertical details band image component; (6). perform inverse wavelet transform to get the corrected polar image; (7). transform the corrected polar image back to Cartesian coordinates to get the CT image slice with reduced ring artifacts. This approach has been successfully used on CT data acquired from the Biomedical Imaging and Therapy (BMIT) beamline in Canadian Light Source (CLS), and the results show that the ring artifacts in original SR CT images have been effectively suppressed with all the structure information in the image preserved.

  1. Free-breathing whole-heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation.

    Science.gov (United States)

    Moghari, Mehdi H; Barthur, Ashita; Amaral, Maria E; Geva, Tal; Powell, Andrew J

    2018-07-01

    To develop and validate a new prospective respiratory motion compensation algorithm for free-breathing whole-heart 3D cine steady-state free precession (SSFP) imaging. In a 3D cine SSFP sequence, 4 excitations per cardiac cycle are re-purposed to prospectively track heart position. Specifically, their 1D image is reconstructed and routed into the scanner's standard diaphragmatic navigator processing system. If all 4 signals are in end-expiration, cine image data from the entire cardiac cycle is accepted for image reconstruction. Prospective validation was carried out in patients (N = 17) by comparing in each a conventional breath-hold 2D cine ventricular short-axis stack and a free-breathing whole-heart 3D cine data set. All 3D cine SSFP acquisitions were successful and the mean scan time was 5.9 ± 2.7 min. Left and right ventricular end-diastolic, end-systolic, and stroke volumes by 3D cine SSFP were all larger than those from 2D cine SSFP. This bias was 3D cine images had a lower ventricular blood-to-myocardium contrast ratio, contrast-to-noise ratio, mass, and subjective quality score. The novel prospective respiratory motion compensation method for 3D cine SSFP imaging was robust and efficient and yielded slightly larger ventricular volumes and lower mass compared to breath-hold 2D cine imaging. Magn Reson Med 80:181-189, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  2. submitter Digital Image Correlation of 2D X-ray Powder Diffraction Data for Lattice Strain Evaluation

    CERN Document Server

    Zhang, Hongjia; Salvati, Enrico; Daisenberger, Dominik; Lunt, Alexander J G; Fong, Kai Soon; Song, Xu; Korsunsky, Alexander M

    2018-01-01

    High energy 2D X-ray powder diffraction experiments are widely used for lattice strain measurement. The 2D to 1D conversion of diffraction patterns is a necessary step used to prepare the data for full pattern refinement, but is inefficient when only peak centre position information is required for lattice strain evaluation. The multi-step conversion process is likely to lead to increased errors associated with the ‘caking’ (radial binning) or fitting procedures. A new method is proposed here that relies on direct Digital Image Correlation analysis of 2D X-ray powder diffraction patterns (XRD-DIC, for short). As an example of using XRD-DIC, residual strain values along the central line in a Mg AZ31B alloy bar after 3-point bending are calculated by using both XRD-DIC and the conventional ‘caking’ with fitting procedures. Comparison of the results for strain values in different azimuthal angles demonstrates excellent agreement between the two methods. The principal strains and directions are calculated...

  3. 3D shape recovery from image focus using gray level co-occurrence matrix

    Science.gov (United States)

    Mahmood, Fahad; Munir, Umair; Mehmood, Fahad; Iqbal, Javaid

    2018-04-01

    Recovering a precise and accurate 3-D shape of the target object utilizing robust 3-D shape recovery algorithm is an ultimate objective of computer vision community. Focus measure algorithm plays an important role in this architecture which convert the color values of each pixel of the acquired 2-D image dataset into corresponding focus values. After convolving the focus measure filter with the input 2-D image dataset, a 3-D shape recovery approach is applied which will recover the depth map. In this document, we are concerned with proposing Gray Level Co-occurrence Matrix along with its statistical features for computing the focus information of the image dataset. The Gray Level Co-occurrence Matrix quantifies the texture present in the image using statistical features and then applies joint probability distributive function of the gray level pairs of the input image. Finally, we quantify the focus value of the input image using Gaussian Mixture Model. Due to its little computational complexity, sharp focus measure curve, robust to random noise sources and accuracy, it is considered as superior alternative to most of recently proposed 3-D shape recovery approaches. This algorithm is deeply investigated on real image sequences and synthetic image dataset. The efficiency of the proposed scheme is also compared with the state of art 3-D shape recovery approaches. Finally, by means of two global statistical measures, root mean square error and correlation, we claim that this approach -in spite of simplicity generates accurate results.

  4. A hybrid spatial-spectral denoising method for infrared hyperspectral images using 2DPCA

    Science.gov (United States)

    Huang, Jun; Ma, Yong; Mei, Xiaoguang; Fan, Fan

    2016-11-01

    The traditional noise reduction methods for 3-D infrared hyperspectral images typically operate independently in either the spatial or spectral domain, and such methods overlook the relationship between the two domains. To address this issue, we propose a hybrid spatial-spectral method in this paper to link both domains. First, principal component analysis and bivariate wavelet shrinkage are performed in the 2-D spatial domain. Second, 2-D principal component analysis transformation is conducted in the 1-D spectral domain to separate the basic components from detail ones. The energy distribution of noise is unaffected by orthogonal transformation; therefore, the signal-to-noise ratio of each component is used as a criterion to determine whether a component should be protected from over-denoising or denoised with certain 1-D denoising methods. This study implements the 1-D wavelet shrinking threshold method based on Stein's unbiased risk estimator, and the quantitative results on publicly available datasets demonstrate that our method can improve denoising performance more effectively than other state-of-the-art methods can.

  5. 4-D ICE: A 2-D Array Transducer With Integrated ASIC in a 10-Fr Catheter for Real-Time 3-D Intracardiac Echocardiography.

    Science.gov (United States)

    Wildes, Douglas; Lee, Warren; Haider, Bruno; Cogan, Scott; Sundaresan, Krishnakumar; Mills, David M; Yetter, Christopher; Hart, Patrick H; Haun, Christopher R; Concepcion, Mikael; Kirkhorn, Johan; Bitoun, Marc

    2016-12-01

    We developed a 2.5 ×6.6 mm 2 2 -D array transducer with integrated transmit/receive application-specific integrated circuit (ASIC) for real-time 3-D intracardiac echocardiography (4-D ICE) applications. The ASIC and transducer design were optimized so that the high-voltage transmit, low-voltage time-gain control and preamp, subaperture beamformer, and digital control circuits for each transducer element all fit within the 0.019-mm 2 area of the element. The transducer assembly was deployed in a 10-Fr (3.3-mm diameter) catheter, integrated with a GE Vivid E9 ultrasound imaging system, and evaluated in three preclinical studies. The 2-D image quality and imaging modes were comparable to commercial 2-D ICE catheters. The 4-D field of view was at least 90 ° ×60 ° ×8 cm and could be imaged at 30 vol/s, sufficient to visualize cardiac anatomy and other diagnostic and therapy catheters. 4-D ICE should significantly reduce X-ray fluoroscopy use and dose during electrophysiology ablation procedures. 4-D ICE may be able to replace transesophageal echocardiography (TEE), and the associated risks and costs of general anesthesia, for guidance of some structural heart procedures.

  6. GPU acceleration towards real-time image reconstruction in 3D tomographic diffractive microscopy

    Science.gov (United States)

    Bailleul, J.; Simon, B.; Debailleul, M.; Liu, H.; Haeberlé, O.

    2012-06-01

    Phase microscopy techniques regained interest in allowing for the observation of unprepared specimens with excellent temporal resolution. Tomographic diffractive microscopy is an extension of holographic microscopy which permits 3D observations with a finer resolution than incoherent light microscopes. Specimens are imaged by a series of 2D holograms: their accumulation progressively fills the range of frequencies of the specimen in Fourier space. A 3D inverse FFT eventually provides a spatial image of the specimen. Consequently, acquisition then reconstruction are mandatory to produce an image that could prelude real-time control of the observed specimen. The MIPS Laboratory has built a tomographic diffractive microscope with an unsurpassed 130nm resolution but a low imaging speed - no less than one minute. Afterwards, a high-end PC reconstructs the 3D image in 20 seconds. We now expect an interactive system providing preview images during the acquisition for monitoring purposes. We first present a prototype implementing this solution on CPU: acquisition and reconstruction are tied in a producer-consumer scheme, sharing common data into CPU memory. Then we present a prototype dispatching some reconstruction tasks to GPU in order to take advantage of SIMDparallelization for FFT and higher bandwidth for filtering operations. The CPU scheme takes 6 seconds for a 3D image update while the GPU scheme can go down to 2 or > 1 seconds depending on the GPU class. This opens opportunities for 4D imaging of living organisms or crystallization processes. We also consider the relevance of GPU for 3D image interaction in our specific conditions.

  7. MO-F-CAMPUS-J-03: Sorting 2D Dynamic MR Images Using Internal Respiratory Signal for 4D MRI

    International Nuclear Information System (INIS)

    Wen, Z; Hui, C; Beddar, S; Stemkens, B; Tijssen, R; Berg, C van den

    2015-01-01

    Purpose: To develop a novel algorithm to extract internal respiratory signal (IRS) for sorting dynamic magnetic resonance (MR) images in order to achieve four-dimensional (4D) MR imaging. Methods: Dynamic MR images were obtained with the balanced steady state free precession by acquiring each two-dimensional sagittal slice repeatedly for more than one breathing cycle. To generate a robust IRS, we used 5 different representative internal respiratory surrogates in both the image space (body area) and the Fourier space (the first two low-frequency phase components in the anterior-posterior direction, and the first two low-frequency phase components in the superior-inferior direction). A clustering algorithm was then used to search for a group of similar individual internal signals, which was then used to formulate the final IRS. A phantom study and a volunteer study were performed to demonstrate the effectiveness of this algorithm. The IRS was compared to the signal from the respiratory bellows. Results: The IRS computed by our algorithm matched well with the bellows signal in both the phantom and the volunteer studies. On average, the normalized cross correlation between the IRS and the bellows signal was 0.97 in the phantom study and 0.87 in the volunteer study, respectively. The average difference between the end inspiration times in the IRS and bellows signal was 0.18 s in the phantom study and 0.14 s in the volunteer study, respectively. 4D images sorted based on the IRS showed minimal mismatched artifacts, and the motion of the anatomy was coherent with the respiratory phases. Conclusion: A novel algorithm was developed to generate IRS from dynamic MR images to achieve 4D MR imaging. The performance of the IRS was comparable to that of the bellows signal. It can be easily implemented into the clinic and potentially could replace the use of external respiratory surrogates. This research was partially funded by the the Center for Radiation Oncology Research from

  8. Single-breath-hold 3-D CINE imaging of the left ventricle using Cartesian sampling.

    Science.gov (United States)

    Wetzl, Jens; Schmidt, Michaela; Pontana, François; Longère, Benjamin; Lugauer, Felix; Maier, Andreas; Hornegger, Joachim; Forman, Christoph

    2018-02-01

    Our objectives were to evaluate a single-breath-hold approach for Cartesian 3-D CINE imaging of the left ventricle with a nearly isotropic resolution of [Formula: see text] and a breath-hold duration of [Formula: see text]19 s against a standard stack of 2-D CINE slices acquired in multiple breath-holds. Validation is performed with data sets from ten healthy volunteers. A Cartesian sampling pattern based on the spiral phyllotaxis and a compressed sensing reconstruction method are proposed to allow 3-D CINE imaging with high acceleration factors. The fully integrated reconstruction uses multiple graphics processing units to speed up the reconstruction. The 2-D CINE and 3-D CINE are compared based on ventricular function parameters, contrast-to-noise ratio and edge sharpness measurements. Visual comparisons of corresponding short-axis slices of 2-D and 3-D CINE show an excellent match, while 3-D CINE also allows reformatting to other orientations. Ventricular function parameters do not significantly differ from values based on 2-D CINE imaging. Reconstruction times are below 4 min. We demonstrate single-breath-hold 3-D CINE imaging in volunteers and three example patient cases, which features fast reconstruction and allows reformatting to arbitrary orientations.

  9. Study of flow around model of cooling tower by means of 2D Particle Image Velocimetry measurement

    Science.gov (United States)

    Barraclough, Veronika; Novotný, Jan; Šafařík, Pavel

    This paper deals with flow around a bluff body of hyperboloid shape. It combines results gathered in the course of research by means of Particle Image Velocimetry (PIV). The experiments were carried out by means of low-frequency 2D PIV and the Reynolds number was 43 000.

  10. Spatially resolved D-T(2) correlation NMR of porous media.

    Science.gov (United States)

    Zhang, Yan; Blümich, Bernhard

    2014-05-01

    Within the past decade, 2D Laplace nuclear magnetic resonance (NMR) has been developed to analyze pore geometry and diffusion of fluids in porous media on the micrometer scale. Many objects like rocks and concrete are heterogeneous on the macroscopic scale, and an integral analysis of microscopic properties provides volume-averaged information. Magnetic resonance imaging (MRI) resolves this spatial average on the contrast scale set by the particular MRI technique. Desirable contrast parameters for studies of fluid transport in porous media derive from the pore-size distribution and the pore connectivity. These microscopic parameters are accessed by 1D and 2D Laplace NMR techniques. It is therefore desirable to combine MRI and 2D Laplace NMR to image functional information on fluid transport in porous media. Because 2D Laplace resolved MRI demands excessive measuring time, this study investigates the possibility to restrict the 2D Laplace analysis to the sum signals from low-resolution pixels, which correspond to pixels of similar amplitude in high-resolution images. In this exploratory study spatially resolved D-T2 correlation maps from glass beads and mortar are analyzed. Regions of similar contrast are first identified in high-resolution images to locate corresponding pixels in low-resolution images generated with D-T2 resolved MRI for subsequent pixel summation to improve the signal-to-noise ratio of contrast-specific D-T2 maps. This method is expected to contribute valuable information on correlated sample heterogeneity from the macroscopic and the microscopic scales in various types of porous materials including building materials and rock. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. 3D segmentation of kidney tumors from freehand 2D ultrasound

    Science.gov (United States)

    Ahmad, Anis; Cool, Derek; Chew, Ben H.; Pautler, Stephen E.; Peters, Terry M.

    2006-03-01

    To completely remove a tumor from a diseased kidney, while minimizing the resection of healthy tissue, the surgeon must be able to accurately determine its location, size and shape. Currently, the surgeon mentally estimates these parameters by examining pre-operative Computed Tomography (CT) images of the patient's anatomy. However, these images do not reflect the state of the abdomen or organ during surgery. Furthermore, these images can be difficult to place in proper clinical context. We propose using Ultrasound (US) to acquire images of the tumor and the surrounding tissues in real-time, then segmenting these US images to present the tumor as a three dimensional (3D) surface. Given the common use of laparoscopic procedures that inhibit the range of motion of the operator, we propose segmenting arbitrarily placed and oriented US slices individually using a tracked US probe. Given the known location and orientation of the US probe, we can assign 3D coordinates to the segmented slices and use them as input to a 3D surface reconstruction algorithm. We have implemented two approaches for 3D segmentation from freehand 2D ultrasound. Each approach was evaluated on a tissue-mimicking phantom of a kidney tumor. The performance of our approach was determined by measuring RMS surface error between the segmentation and the known gold standard and was found to be below 0.8 mm.

  12. 3D widefield light microscope image reconstruction without dyes

    Science.gov (United States)

    Larkin, S.; Larson, J.; Holmes, C.; Vaicik, M.; Turturro, M.; Jurkevich, A.; Sinha, S.; Ezashi, T.; Papavasiliou, G.; Brey, E.; Holmes, T.

    2015-03-01

    3D image reconstruction using light microscope modalities without exogenous contrast agents is proposed and investigated as an approach to produce 3D images of biological samples for live imaging applications. Multimodality and multispectral imaging, used in concert with this 3D optical sectioning approach is also proposed as a way to further produce contrast that could be specific to components in the sample. The methods avoid usage of contrast agents. Contrast agents, such as fluorescent or absorbing dyes, can be toxic to cells or alter cell behavior. Current modes of producing 3D image sets from a light microscope, such as 3D deconvolution algorithms and confocal microscopy generally require contrast agents. Zernike phase contrast (ZPC), transmitted light brightfield (TLB), darkfield microscopy and others can produce contrast without dyes. Some of these modalities have not previously benefitted from 3D image reconstruction algorithms, however. The 3D image reconstruction algorithm is based on an underlying physical model of scattering potential, expressed as the sample's 3D absorption and phase quantities. The algorithm is based upon optimizing an objective function - the I-divergence - while solving for the 3D absorption and phase quantities. Unlike typical deconvolution algorithms, each microscope modality, such as ZPC or TLB, produces two output image sets instead of one. Contrast in the displayed image and 3D renderings is further enabled by treating the multispectral/multimodal data as a feature set in a mathematical formulation that uses the principal component method of statistics.

  13. Improvement of temporal and dynamic subtraction images on abdominal CT using 3D global image matching and nonlinear image warping techniques

    International Nuclear Information System (INIS)

    Okumura, E; Sanada, S; Suzuki, M; Takemura, A; Matsui, O

    2007-01-01

    Accurate registration of the corresponding non-enhanced and arterial-phase CT images is necessary to create temporal and dynamic subtraction images for the enhancement of subtle abnormalities. However, respiratory movement causes misregistration at the periphery of the liver. To reduce these misregistration errors, we developed a temporal and dynamic subtraction technique to enhance small HCC by 3D global matching and nonlinear image warping techniques. The study population consisted of 21 patients with HCC. Using the 3D global matching and nonlinear image warping technique, we registered current and previous arterial-phase CT images or current non-enhanced and arterial-phase CT images obtained in the same position. The temporal subtraction image was obtained by subtracting the previous arterial-phase CT image from the warped current arterial-phase CT image. The dynamic subtraction image was obtained by the subtraction of the current non-enhanced CT image from the warped current arterial-phase CT image. The percentage of fair or superior temporal subtraction images increased from 52.4% to 95.2% using the new technique, while on the dynamic subtraction images, the percentage increased from 66.6% to 95.2%. The new subtraction technique may facilitate the diagnosis of subtle HCC based on the superior ability of these subtraction images to show nodular and/or ring enhancement

  14. 2D-3D shape reconstruction of the distal femur from stereo X-Ray imaging using statistical shape models

    DEFF Research Database (Denmark)

    Baka, N.; Kaptein, B. L.; de Bruijne, Marleen

    2011-01-01

    Three-dimensional patient specific bone models are required in a range of medical applications, such as pre-operative surgery planning and improved guidance during surgery, modeling and simulation, and in vivo bone motion tracking. Shape reconstruction from a small number of X-ray images is desired...... as it lowers both the acquisition costs and the radiation dose compared to CT. We propose a method for pose estimation and shape reconstruction of 3D bone surfaces from two (or more) calibrated X-ray images using a statistical shape model (SSM). User interaction is limited to manual initialization of the mean...... pose estimation of ground truth shapes as well as 3D shape estimation using a SSM of the whole femur, from stereo cadaver X-rays, in vivo biplane fluoroscopy image-pairs, and an in vivo biplane fluoroscopic sequence. Ground truth shapes for all experiments were available in the form of CT segmentations...

  15. Pose-Invariant Face Recognition via RGB-D Images.

    Science.gov (United States)

    Sang, Gaoli; Li, Jing; Zhao, Qijun

    2016-01-01

    Three-dimensional (3D) face models can intrinsically handle large pose face recognition problem. In this paper, we propose a novel pose-invariant face recognition method via RGB-D images. By employing depth, our method is able to handle self-occlusion and deformation, both of which are challenging problems in two-dimensional (2D) face recognition. Texture images in the gallery can be rendered to the same view as the probe via depth. Meanwhile, depth is also used for similarity measure via frontalization and symmetric filling. Finally, both texture and depth contribute to the final identity estimation. Experiments on Bosphorus, CurtinFaces, Eurecom, and Kiwi databases demonstrate that the additional depth information has improved the performance of face recognition with large pose variations and under even more challenging conditions.

  16. Automatic ultrasound image enhancement for 2D semi-automatic breast-lesion segmentation

    Science.gov (United States)

    Lu, Kongkuo; Hall, Christopher S.

    2014-03-01

    Breast cancer is the fastest growing cancer, accounting for 29%, of new cases in 2012, and second leading cause of cancer death among women in the United States and worldwide. Ultrasound (US) has been used as an indispensable tool for breast cancer detection/diagnosis and treatment. In computer-aided assistance, lesion segmentation is a preliminary but vital step, but the task is quite challenging in US images, due to imaging artifacts that complicate detection and measurement of the suspect lesions. The lesions usually present with poor boundary features and vary significantly in size, shape, and intensity distribution between cases. Automatic methods are highly application dependent while manual tracing methods are extremely time consuming and have a great deal of intra- and inter- observer variability. Semi-automatic approaches are designed to counterbalance the advantage and drawbacks of the automatic and manual methods. However, considerable user interaction might be necessary to ensure reasonable segmentation for a wide range of lesions. This work proposes an automatic enhancement approach to improve the boundary searching ability of the live wire method to reduce necessary user interaction while keeping the segmentation performance. Based on the results of segmentation of 50 2D breast lesions in US images, less user interaction is required to achieve desired accuracy, i.e. < 80%, when auto-enhancement is applied for live-wire segmentation.

  17. Analysis of information for cerebrovascular disorders obtained by 3D MR imaging

    International Nuclear Information System (INIS)

    Yoshikawa, Kohki; Yoshioka, Naoki; Watanabe, Fumio; Shiono, Takahiro; Sugishita, Morihiro; Umino, Kazunori.

    1995-01-01

    Recently, it becomes easy to analyze information obtained by 3D MR imaging due to remarkable progress of fast MR imaging technique and analysis tool. Six patients suffered from aphasia (4 cerebral infarctions and 2 bleedings) were performed 3D MR imaging (3D FLASH-TR/TE/flip angle; 20-50 msec/6-10 msec/20-30 degrees) and their volume information were analyzed by multiple projection reconstruction (MPR), surface rendering 3D reconstruction, and volume rendering 3D reconstruction using Volume Design PRO (Medical Design Co., Ltd.). Four of them were diagnosed as Broca's aphasia clinically and their lesions could be detected around the cortices of the left inferior frontal gyrus. Another 2 patients were diagnosed as Wernicke's aphasia and the lesions could be detected around the cortices of the left supramarginal gyrus. This technique for 3D volume analyses would provide quite exact locational information about cerebral cortical lesions. (author)

  18. Analysis of information for cerebrovascular disorders obtained by 3D MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kohki [Tokyo Univ. (Japan). Inst. of Medical Science; Yoshioka, Naoki; Watanabe, Fumio; Shiono, Takahiro; Sugishita, Morihiro; Umino, Kazunori

    1995-12-01

    Recently, it becomes easy to analyze information obtained by 3D MR imaging due to remarkable progress of fast MR imaging technique and analysis tool. Six patients suffered from aphasia (4 cerebral infarctions and 2 bleedings) were performed 3D MR imaging (3D FLASH-TR/TE/flip angle; 20-50 msec/6-10 msec/20-30 degrees) and their volume information were analyzed by multiple projection reconstruction (MPR), surface rendering 3D reconstruction, and volume rendering 3D reconstruction using Volume Design PRO (Medical Design Co., Ltd.). Four of them were diagnosed as Broca`s aphasia clinically and their lesions could be detected around the cortices of the left inferior frontal gyrus. Another 2 patients were diagnosed as Wernicke`s aphasia and the lesions could be detected around the cortices of the left supramarginal gyrus. This technique for 3D volume analyses would provide quite exact locational information about cerebral cortical lesions. (author).

  19. 2-D or 3-D Mammography?: The Future of Breast Cancer Detection | NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... Future of Breast Cancer Detection Follow us 2-D or 3-D Mammography?: The Future of Breast Cancer Detection NIH- ... will test two types of imaging tools—2-D and 3-D mammography. 2-D mammography takes ...

  20. Identification of the critical depth-of-cut through a 2D image of the cutting region resulting from taper cutting of brittle materials

    Science.gov (United States)

    Gu, Wen; Zhu, Zhiwei; Zhu, Wu-Le; Lu, Leyao; To, Suet; Xiao, Gaobo

    2018-05-01

    An automatic identification method for obtaining the critical depth-of-cut (DoC) of brittle materials with nanometric accuracy and sub-nanometric uncertainty is proposed in this paper. With this method, a two-dimensional (2D) microscopic image of the taper cutting region is captured and further processed by image analysis to extract the margin of generated micro-cracks in the imaging plane. Meanwhile, an analytical model is formulated to describe the theoretical curve of the projected cutting points on the imaging plane with respect to a specified DoC during the whole cutting process. By adopting differential evolution algorithm-based minimization, the critical DoC can be identified by minimizing the deviation between the extracted margin and the theoretical curve. The proposed method is demonstrated through both numerical simulation and experimental analysis. Compared with conventional 2D- and 3D-microscopic-image-based methods, determination of the critical DoC in this study uses the envelope profile rather than the onset point of the generated cracks, providing a more objective approach with smaller uncertainty.

  1. Study of flow around model of cooling tower by means of 2D Particle Image Velocimetry measurement

    Directory of Open Access Journals (Sweden)

    Barraclough Veronika

    2017-01-01

    Full Text Available This paper deals with flow around a bluff body of hyperboloid shape. It combines results gathered in the course of research by means of Particle Image Velocimetry (PIV. The experiments were carried out by means of low-frequency 2D PIV and the Reynolds number was 43 000.

  2. Validation of the Gatortail method for accurate sizing of pulmonary vessels from 3D medical images.

    Science.gov (United States)

    O'Dell, Walter G; Gormaley, Anne K; Prida, David A

    2017-12-01

    Detailed characterization of changes in vessel size is crucial for the diagnosis and management of a variety of vascular diseases. Because clinical measurement of vessel size is typically dependent on the radiologist's subjective interpretation of the vessel borders, it is often prone to high inter- and intra-user variability. Automatic methods of vessel sizing have been developed for two-dimensional images but a fully three-dimensional (3D) method suitable for vessel sizing from volumetric X-ray computed tomography (CT) or magnetic resonance imaging has heretofore not been demonstrated and validated robustly. In this paper, we refined and objectively validated Gatortail, a method that creates a mathematical geometric 3D model of each branch in a vascular tree, simulates the appearance of the virtual vascular tree in a 3D CT image, and uses the similarity of the simulated image to a patient's CT scan to drive the optimization of the model parameters, including vessel size, to match that of the patient. The method was validated with a 2-dimensional virtual tree structure under deformation, and with a realistic 3D-printed vascular phantom in which the diameter of 64 branches were manually measured 3 times each. The phantom was then scanned on a conventional clinical CT imaging system and the images processed with the in-house software to automatically segment and mathematically model the vascular tree, label each branch, and perform the Gatortail optimization of branch size and trajectory. Previously proposed methods of vessel sizing using matched Gaussian filters and tubularity metrics were also tested. The Gatortail method was then demonstrated on the pulmonary arterial tree segmented from a human volunteer's CT scan. The standard deviation of the difference between the manually measured and Gatortail-based radii in the 3D physical phantom was 0.074 mm (0.087 in-plane pixel units for image voxels of dimension 0.85 × 0.85 × 1.0 mm) over the 64 branches

  3. The findings and the role of axial CT imaging and 3D imaging of gastric lesion by spiral CT

    International Nuclear Information System (INIS)

    Lee, Dong Ho; Ko, Young Tae

    1996-01-01

    The purpose of this study is to assess the efficacy of axial CT imaging and 3D imaging by spiral CT in the detection and evaluation of gastric lesion. Seventy-seven patients with pathologically-proven gastric lesions underwent axial CT and 3D imaging by spiral CT. There were 49 cases of advanced gastric carcinoma(AGC), 21 of early gastric carcinoma (EGC), three of benign ulcers, three of leiomyomas, and one case of lymphoma. Spiral CT was performed with 3-mm collimation, 4.5mm/sec table feed, and 1-1.5-mm reconstruction interval after the ingestion of gas. 3D imaging was obtained using the SSD technique, and on analysis a grade was given(excellent, good, poor). Axial CT scan was performed with 5-mm collimation, 7mm/sec table feed, and 5-mm reconstruction interval after the ingestion of water. Among 49 cases of AGC, excellent 3D images were obtained in seven patients (14.3%), good 3D images in 30(61.2%), and poor 3D images in 12(24.5%). Among the 12 patients with poor images, the cancers were located at the pyloric antrum in eight cases, were AGC Borrmann type 4 in three cases, and EGC-mimicking lesion in one case. Using axial CT scan alone, Borrmann's classification based tumor morphology were accurately identified in 67.3% of cases, but using 3D imaging, the corresponding figure was 85.7%. In 33 cases receiving surgery, good correlation between axial CT scan and pathology occurred in 72.7% of T class, and 69.7% of N class. Among 21 cases of EGC, excellent 3D images were obtained in three patients (14.3%), good 3D images in 14 (66.7%), and poor 3D images in two (9.5%). The other two cases of EGC were not detected. By axial CT scan, no tumor was detected in four cases, and there were two doubtful cases. 3D images of three benign ulcers were excellent in one case and good in two. 3D images of three leiomyomas and one lymphoma were excellent. Combined axial CT imaging and 3D imaging by spiral CT has the potential to accurately diagnose gastric lesions other than AGC

  4. Fast multi-core based multimodal registration of 2D cross-sections and 3D datasets

    Directory of Open Access Journals (Sweden)

    Pielot Rainer

    2010-01-01

    Full Text Available Abstract Background Solving bioinformatics tasks often requires extensive computational power. Recent trends in processor architecture combine multiple cores into a single chip to improve overall performance. The Cell Broadband Engine (CBE, a heterogeneous multi-core processor, provides power-efficient and cost-effective high-performance computing. One application area is image analysis and visualisation, in particular registration of 2D cross-sections into 3D image datasets. Such techniques can be used to put different image modalities into spatial correspondence, for example, 2D images of histological cuts into morphological 3D frameworks. Results We evaluate the CBE-driven PlayStation 3 as a high performance, cost-effective computing platform by adapting a multimodal alignment procedure to several characteristic hardware properties. The optimisations are based on partitioning, vectorisation, branch reducing and loop unrolling techniques with special attention to 32-bit multiplies and limited local storage on the computing units. We show how a typical image analysis and visualisation problem, the multimodal registration of 2D cross-sections and 3D datasets, benefits from the multi-core based implementation of the alignment algorithm. We discuss several CBE-based optimisation methods and compare our results to standard solutions. More information and the source code are available from http://cbe.ipk-gatersleben.de. Conclusions The results demonstrate that the CBE processor in a PlayStation 3 accelerates computational intensive multimodal registration, which is of great importance in biological/medical image processing. The PlayStation 3 as a low cost CBE-based platform offers an efficient option to conventional hardware to solve computational problems in image processing and bioinformatics.

  5. H-Ransac a Hybrid Point Cloud Segmentation Combining 2d and 3d Data

    Science.gov (United States)

    Adam, A.; Chatzilari, E.; Nikolopoulos, S.; Kompatsiaris, I.

    2018-05-01

    In this paper, we present a novel 3D segmentation approach operating on point clouds generated from overlapping images. The aim of the proposed hybrid approach is to effectively segment co-planar objects, by leveraging the structural information originating from the 3D point cloud and the visual information from the 2D images, without resorting to learning based procedures. More specifically, the proposed hybrid approach, H-RANSAC, is an extension of the well-known RANSAC plane-fitting algorithm, incorporating an additional consistency criterion based on the results of 2D segmentation. Our expectation that the integration of 2D data into 3D segmentation will achieve more accurate results, is validated experimentally in the domain of 3D city models. Results show that HRANSAC can successfully delineate building components like main facades and windows, and provide more accurate segmentation results compared to the typical RANSAC plane-fitting algorithm.

  6. Accuracy and reliability of 3D stereophotogrammetry: A comparison to direct anthropometry and 2D photogrammetry.

    Science.gov (United States)

    Dindaroğlu, Furkan; Kutlu, Pınar; Duran, Gökhan Serhat; Görgülü, Serkan; Aslan, Erhan

    2016-05-01

    To evaluate the accuracy of three-dimensional (3D) stereophotogrammetry by comparing it with the direct anthropometry and digital photogrammetry methods. The reliability of 3D stereophotogrammetry was also examined. Six profile and four frontal parameters were directly measured on the faces of 80 participants. The same measurements were repeated using two-dimensional (2D) photogrammetry and 3D stereophotogrammetry (3dMDflex System, 3dMD, Atlanta, Ga) to obtain images of the subjects. Another observer made the same measurements for images obtained with 3D stereophotogrammetry, and interobserver reproducibility was evaluated for 3D images. Both observers remeasured the 3D images 1 month later, and intraobserver reproducibility was evaluated. Statistical analysis was conducted using the paired samples t-test, intraclass correlation coefficient, and Bland-Altman limits of agreement. The highest mean difference was 0.30 mm between direct measurement and photogrammetry, 0.21 mm between direct measurement and 3D stereophotogrammetry, and 0.5 mm between photogrammetry and 3D stereophotogrammetry. The lowest agreement value was 0.965 in the Sn-Pro parameter between the photogrammetry and 3D stereophotogrammetry methods. Agreement between the two observers varied from 0.90 (Ch-Ch) to 0.99 (Sn-Me) in linear measurements. For intraobserver agreement, the highest difference between means was 0.33 for observer 1 and 1.42 mm for observer 2. Measurements obtained using 3D stereophotogrammetry indicate that it may be an accurate and reliable imaging method for use in orthodontics.

  7. Particle image velocimetry measurements of 2-dimensional velocity field around twisted tape

    Energy Technology Data Exchange (ETDEWEB)

    Song, Min Seop; Park, So Hyun; Kim, Eung Soo, E-mail: kes7741@snu.ac.kr

    2016-11-01

    Highlights: • Measurements of the flow field in a pipe with twisted tape were conducted by particle image velocimetry (PIV). • A novel matching index of refraction technique utilizing 3D printing and oil mixture was adopted to make the test section transparent. • Undistorted particle images were clearly captured in the presence of twisted tape. • 2D flow field in the pipe with twisted tape revealed the characteristic two-peak velocity profile. - Abstract: Twisted tape is a passive component used to enhance heat exchange in various devices. It induces swirl flow that increases the mixing of fluid. Thus, ITER selected the twisted tape as one of the candidates for turbulence promoting in the divertor cooling. Previous study was mainly focused on the thermohydraulic performance of the twisted tape. As detailed data on the velocity field around the twisted tape was insufficient, flow visualization study was performed to provide fundamental data on velocity field. To visualize the flow in a complex structure, novel matching index of refraction technique was used with 3-D printing and mixture of anise and mineral oil. This technique enables the camera to capture undistorted particle image for velocity field measurement. Velocity fields at Reynolds number 1370–9591 for 3 different measurement plane were obtained through particle image velocimetry. The 2-dimensional averaged velocity field data were obtained from 177 pair of instantaneous velocity fields. It reveals the characteristic two-peak flow motion in axial direction. In addition, the normalized velocity profiles were converged with increase of Reynolds numbers. Finally, the uncertainty of the result data was analyzed.

  8. 2D or Not 2D? Testing the Utility of 2D Vs. 3D Landmark Data in Geometric Morphometrics of the Sculpin Subfamily Oligocottinae (Pisces; Cottoidea).

    Science.gov (United States)

    Buser, Thaddaeus J; Sidlauskas, Brian L; Summers, Adam P

    2018-05-01

    We contrast 2D vs. 3D landmark-based geometric morphometrics in the fish subfamily Oligocottinae by using 3D landmarks from CT-generated models and comparing the morphospace of the 3D landmarks to one based on 2D landmarks from images. The 2D and 3D shape variables capture common patterns across taxa, such that the pairwise Procrustes distances among taxa correspond and the trends captured by principal component analysis are similar in the xy plane. We use the two sets of landmarks to test several ecomorphological hypotheses from the literature. Both 2D and 3D data reject the hypothesis that head shape correlates significantly with the depth at which a species is commonly found. However, in taxa where shape variation in the z-axis is high, the 2D shape variables show sufficiently strong distortion to influence the outcome of the hypothesis tests regarding the relationship between mouth size and feeding ecology. Only the 3D data support previous studies which showed that large mouth sizes correlate positively with high percentages of elusive prey in the diet. When used to test for morphological divergence, 3D data show no evidence of divergence, while 2D data show that one clade of oligocottines has diverged from all others. This clade shows the greatest degree of z-axis body depth within Oligocottinae, and we conclude that the inability of the 2D approach to capture this lateral body depth causes the incongruence between 2D and 3D analyses. Anat Rec, 301:806-818, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  9. Oculomotor paralysis: 3D-CISS MR imaging with MPR in the evaluation of neuralgic manifestation and the adjacent structures

    Energy Technology Data Exchange (ETDEWEB)

    Sun Xiaoli; Liang Changhu [Shandong Medical Imaging Research Institute, Shandong University, Jing-wu Road No. 324, Jinan 250021 (China); Liu Cheng [Shandong Medical Imaging Research Institute, Shandong University, Jing-wu Road No. 324, Jinan 250021 (China)], E-mail: sdsxl2005@126.com; Liu Shuwei; Deng Kai; He Jingzhen [Shandong Medical Imaging Research Institute, Shandong University, Jing-wu Road No. 324, Jinan 250021 (China)

    2010-02-15

    Purpose: To evaluate the value of three-dimensional (3D) constructive interference in steady-state (CISS) magnetic resonance (MR) imaging with multi-planar reconstruction (MPR) in displaying the relationship between the oculomotor nerve and its adjacent structures for patients with oculomotor paralysis. Materials and methods: 17 consecutive patients with oculomotor paralysis were examined with 3D-CISS and conventional spin-echo (SE) sequences on a 1.5-Tesla MR system. Original transverse and MPR images were used for image interpretation. The features of the oculomotor nerve and its adjacent structures were identified. The diagnosis was surgically confirmed in all patients. Results: Through 3D-CISS with MPR images, obvious relationship of the oculomotor nerve and its adjacent structures was demonstrated on 17 patients. Of those oculomotor nerves, 15 were compressed by the arteries (n = 15), one by the craniopharyngioma (n = 1), and another one by the neurofibroma (n = 1). Conclusion: 3D-CISS MR imaging with MPR provides an excellent way to characterize the relationship between the nerve and its adjacent structures in the cisternal segment of the oculomotor nerve in the patients with oculomotor paralysis. Moreover, this method shows anatomical details for imaging diagnosis and surgical procedure.

  10. Oculomotor paralysis: 3D-CISS MR imaging with MPR in the evaluation of neuralgic manifestation and the adjacent structures

    International Nuclear Information System (INIS)

    Sun Xiaoli; Liang Changhu; Liu Cheng; Liu Shuwei; Deng Kai; He Jingzhen

    2010-01-01

    Purpose: To evaluate the value of three-dimensional (3D) constructive interference in steady-state (CISS) magnetic resonance (MR) imaging with multi-planar reconstruction (MPR) in displaying the relationship between the oculomotor nerve and its adjacent structures for patients with oculomotor paralysis. Materials and methods: 17 consecutive patients with oculomotor paralysis were examined with 3D-CISS and conventional spin-echo (SE) sequences on a 1.5-Tesla MR system. Original transverse and MPR images were used for image interpretation. The features of the oculomotor nerve and its adjacent structures were identified. The diagnosis was surgically confirmed in all patients. Results: Through 3D-CISS with MPR images, obvious relationship of the oculomotor nerve and its adjacent structures was demonstrated on 17 patients. Of those oculomotor nerves, 15 were compressed by the arteries (n = 15), one by the craniopharyngioma (n = 1), and another one by the neurofibroma (n = 1). Conclusion: 3D-CISS MR imaging with MPR provides an excellent way to characterize the relationship between the nerve and its adjacent structures in the cisternal segment of the oculomotor nerve in the patients with oculomotor paralysis. Moreover, this method shows anatomical details for imaging diagnosis and surgical procedure.

  11. Precision of a photogrammetric method to perform 3D wound measurements compared to standard 2D photographic techniques in the horse.

    Science.gov (United States)

    Labens, R; Blikslager, A

    2013-01-01

    Methods of 3D wound imaging in man play an important role in monitoring of healing and determination of the prognosis. Standard photographic assessments in equine wound management consist of 2D analyses, which provide little quantitative information on the wound bed. 3D imaging of equine wounds is feasible using principles of stereophotogrammetry. 3D measurements differ significantly and are more precise than results with standard 2D assessments. Repeated specialised photographic imaging of 4 clinical wounds left to heal by second intention was performed. The intraoperator variability in measurements due to imaging and 3D processing was compared to that of a standard 2D technique using descriptive statistics and multivariate repeated measures ANOVA. Using a custom made imaging system, 3D analyses were successfully performed. Area and circumference measurements were significantly different between imaging modalities. The intraoperator variability of 3D measurements was up to 2.8 times less than that of 2D results. On average, the maximum discrepancy between repeated measurements was 5.8% of the mean for 3D and 17.3% of the mean for 2D assessments. The intraoperator repeatability of 3D wound measurements based on principles of stereophotogrammetry is significantly increased compared to that of a standard 2D photographic technique indicating it may be a useful diagnostic and monitoring tool. The equine granulation bed plays an important role in equine wound healing. When compared to 2D analyses 3D monitoring of the equine wound bed allows superior quantitative characterisation, contributing to clinical and experimental investigations by offering potential new parameters. © 2012 EVJ Ltd.

  12. The simulation of 3D mass models in 2D digital mammography and breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Shaheen, Eman, E-mail: eman.shaheen@uzleuven.be; De Keyzer, Frederik; Bosmans, Hilde; Ongeval, Chantal Van [Department of Radiology, University Hospitals Leuven, Herestraat 49, 3000 Leuven (Belgium); Dance, David R.; Young, Kenneth C. [National Coordinating Centre for the Physics of Mammography, Royal Surrey County Hospital, Guildford GU2 7XX, United Kingdom and Department of Physics, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH (United Kingdom)

    2014-08-15

    Purpose: This work proposes a new method of building 3D breast mass models with different morphological shapes and describes the validation of the realism of their appearance after simulation into 2D digital mammograms and breast tomosynthesis images. Methods: Twenty-five contrast enhanced MRI breast lesions were collected and each mass was manually segmented in the three orthogonal views: sagittal, coronal, and transversal. The segmented models were combined, resampled to have isotropic voxel sizes, triangularly meshed, and scaled to different sizes. These masses were referred to as nonspiculated masses and were then used as nuclei onto which spicules were grown with an iterative branching algorithm forming a total of 30 spiculated masses. These 55 mass models were projected into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. The realism of the appearance of these mass models was assessed by five radiologists via receiver operating characteristic (ROC) analysis when compared to 54 real masses. All lesions were also given a breast imaging reporting and data system (BIRADS) score. The data sets of 2D mammography and tomosynthesis were read separately. The Kendall's coefficient of concordance was used for the interrater observer agreement assessment for the BIRADS scores per modality. Further paired analysis, using the Wilcoxon signed rank test, of the BIRADS assessment between 2D and tomosynthesis was separately performed for the real masses and for the simulated masses. Results: The area under the ROC curves, averaged over all observers, was 0.54 (95% confidence interval [0.50, 0.66]) for the 2D study, and 0.67 (95% confidence interval [0.55, 0.79]) for the tomosynthesis study. According to the BIRADS scores, the nonspiculated and the spiculated masses varied in their degrees of malignancy from normal (BIRADS 1) to highly

  13. The simulation of 3D mass models in 2D digital mammography and breast tomosynthesis

    International Nuclear Information System (INIS)

    Shaheen, Eman; De Keyzer, Frederik; Bosmans, Hilde; Ongeval, Chantal Van; Dance, David R.; Young, Kenneth C.

    2014-01-01

    Purpose: This work proposes a new method of building 3D breast mass models with different morphological shapes and describes the validation of the realism of their appearance after simulation into 2D digital mammograms and breast tomosynthesis images. Methods: Twenty-five contrast enhanced MRI breast lesions were collected and each mass was manually segmented in the three orthogonal views: sagittal, coronal, and transversal. The segmented models were combined, resampled to have isotropic voxel sizes, triangularly meshed, and scaled to different sizes. These masses were referred to as nonspiculated masses and were then used as nuclei onto which spicules were grown with an iterative branching algorithm forming a total of 30 spiculated masses. These 55 mass models were projected into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. The realism of the appearance of these mass models was assessed by five radiologists via receiver operating characteristic (ROC) analysis when compared to 54 real masses. All lesions were also given a breast imaging reporting and data system (BIRADS) score. The data sets of 2D mammography and tomosynthesis were read separately. The Kendall's coefficient of concordance was used for the interrater observer agreement assessment for the BIRADS scores per modality. Further paired analysis, using the Wilcoxon signed rank test, of the BIRADS assessment between 2D and tomosynthesis was separately performed for the real masses and for the simulated masses. Results: The area under the ROC curves, averaged over all observers, was 0.54 (95% confidence interval [0.50, 0.66]) for the 2D study, and 0.67 (95% confidence interval [0.55, 0.79]) for the tomosynthesis study. According to the BIRADS scores, the nonspiculated and the spiculated masses varied in their degrees of malignancy from normal (BIRADS 1) to highly

  14. The simulation of 3D mass models in 2D digital mammography and breast tomosynthesis.

    Science.gov (United States)

    Shaheen, Eman; De Keyzer, Frederik; Bosmans, Hilde; Dance, David R; Young, Kenneth C; Van Ongeval, Chantal

    2014-08-01

    This work proposes a new method of building 3D breast mass models with different morphological shapes and describes the validation of the realism of their appearance after simulation into 2D digital mammograms and breast tomosynthesis images. Twenty-five contrast enhanced MRI breast lesions were collected and each mass was manually segmented in the three orthogonal views: sagittal, coronal, and transversal. The segmented models were combined, resampled to have isotropic voxel sizes, triangularly meshed, and scaled to different sizes. These masses were referred to as nonspiculated masses and were then used as nuclei onto which spicules were grown with an iterative branching algorithm forming a total of 30 spiculated masses. These 55 mass models were projected into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. The realism of the appearance of these mass models was assessed by five radiologists via receiver operating characteristic (ROC) analysis when compared to 54 real masses. All lesions were also given a breast imaging reporting and data system (BIRADS) score. The data sets of 2D mammography and tomosynthesis were read separately. The Kendall's coefficient of concordance was used for the interrater observer agreement assessment for the BIRADS scores per modality. Further paired analysis, using the Wilcoxon signed rank test, of the BIRADS assessment between 2D and tomosynthesis was separately performed for the real masses and for the simulated masses. The area under the ROC curves, averaged over all observers, was 0.54 (95% confidence interval [0.50, 0.66]) for the 2D study, and 0.67 (95% confidence interval [0.55, 0.79]) for the tomosynthesis study. According to the BIRADS scores, the nonspiculated and the spiculated masses varied in their degrees of malignancy from normal (BIRADS 1) to highly suggestive for malignancy (BIRADS 5

  15. 3D Reconstruction of NMR Images

    Directory of Open Access Journals (Sweden)

    Peter Izak

    2007-01-01

    Full Text Available This paper introduces experiment of 3D reconstruction NMR images scanned from magnetic resonance device. There are described methods which can be used for 3D reconstruction magnetic resonance images in biomedical application. The main idea is based on marching cubes algorithm. For this task was chosen sophistication method by program Vision Assistant, which is a part of program LabVIEW.

  16. Utilizing Semantic Interpretation of Junctions for 3D-2D Pose Estimation

    DEFF Research Database (Denmark)

    Pilz, Florian; Yan, Shi; Grest, Daniel

    2007-01-01

    In this paper we investigate the quality of 3D-2D pose estimates using hand labeled line and point correspondences. We select point correspondences from junctions in the image, allowing to construct a meaningful interpretation about how the junction is formed, as proposed in e.g. [1], [2], [3]. W...

  17. Self-calibration of cone-beam CT geometry using 3D–2D image registration

    Science.gov (United States)

    Ouadah, S; Stayman, J W; Gang, G J; Ehtiati, T; Siewerdsen, J H

    2016-01-01

    Robotic C-arms are capable of complex orbits that can increase field of view, reduce artifacts, improve image quality, and/or reduce dose; however, it can be challenging to obtain accurate, reproducible geometric calibration required for image reconstruction for such complex orbits. This work presents a method for geometric calibration for an arbitrary source-detector orbit by registering 2D projection data to a previously acquired 3D image. It also yields a method by which calibration of simple circular orbits can be improved. The registration uses a normalized gradient information similarity metric and the covariance matrix adaptation-evolution strategy optimizer for robustness against local minima and changes in image content. The resulting transformation provides a ‘self-calibration’ of system geometry. The algorithm was tested in phantom studies using both a cone-beam CT (CBCT) test-bench and a robotic C-arm (Artis Zeego, Siemens Healthcare) for circular and non-circular orbits. Self-calibration performance was evaluated in terms of the full-width at half-maximum (FWHM) of the point spread function in CBCT reconstructions, the reprojection error (RPE) of steel ball bearings placed on each phantom, and the overall quality and presence of artifacts in CBCT images. In all cases, self-calibration improved the FWHM—e.g. on the CBCT bench, FWHM = 0.86 mm for conventional calibration compared to 0.65 mm for self-calibration (p < 0.001). Similar improvements were measured in RPE—e.g. on the robotic C-arm, RPE = 0.73 mm for conventional calibration compared to 0.55 mm for self-calibration (p < 0.001). Visible improvement was evident in CBCT reconstructions using self-calibration, particularly about high-contrast, high-frequency objects (e.g. temporal bone air cells and a surgical needle). The results indicate that self-calibration can improve even upon systems with presumably accurate geometric calibration and is applicable to situations where conventional

  18. 3D isotropic T2-weighted fast spin echo (VISTA) versus 2D T2-weighted fast spin echo in evaluation of the calcaneofibular ligament in the oblique coronal plane.

    Science.gov (United States)

    Park, H J; Lee, S Y; Choi, Y J; Hong, H P; Park, S J; Park, J H; Kim, E

    2017-02-01

    To investigate whether the image quality of three-dimensional (3D) volume isotropic fast spin echo acquisition (VISTA) magnetic resonance imaging (MRI) of the calcaneofibular ligament (CFL) view is comparable to that of 2D fast spin echo T2-weighted images (2D T2 FSE) for the evaluation of the CFL, and whether 3D VISTA can replace 2D T2 FSE for the evaluation of CFL injuries. This retrospective study included 76 patients who underwent ankle MRI with CFL views of both 2D T2 FSE MRI and 3D VISTA. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of both techniques were measured. The anatomical identification score and diagnostic performances were evaluated by two readers independently. The diagnostic performances of 3D VISTA and 2D T2 FSE were analysed by sensitivity, specificity, and accuracy for diagnosing CFL injury with reference standards of surgically or clinically confirmed diagnoses. Surgical correlation was performed in 29% of the patients, and clinical examination was used in those who did not have surgery (71%). The SNRs and CNRs of 3D VISTA were significantly higher than those of 2D T2 FSE. The anatomical identification scores on 3D VISTA were inferior to those on 2D T2 FSE, and the differences were statistically significant (pT2 FSE for the anatomical evaluation of CFL, 3D VISTA has a diagnostic performance comparable to that of 2D T2 FSE for the diagnosis of CFL injuries. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  19. Individualized directional microphone optimization in hearing aids based on reconstructing the 3D geometry of the head and ear from 2D images

    DEFF Research Database (Denmark)

    Harder, Stine

    head model based on 2D images, the second step is to simulate individual head related transfer functions (HRTFs) based on the estimated 3D head model and the final step is to calculate optimal directional filters based on the simulated HRTFs. The pipeline is employed on a Behind-The-Ear (BTE) hearing...... against non-individual directional filters revealed equally high Articulation-Index weighted Directivity Index (AI-DI) values for our specific test subject. However, measurements on other individuals indicate that the performance of the non-individual filters vary among subjects, and in particular...

  20. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms

    International Nuclear Information System (INIS)

    Bieniosek, Matthew F.; Lee, Brian J.; Levin, Craig S.

    2015-01-01

    Purpose: Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial “Micro Deluxe” phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom with sub-mm features. Methods: CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results: Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. Conclusions: This work shows that 3D printed