WorldWideScience

Sample records for descending thoracic aortic

  1. Quantification of progression and regression of descending thoracic aortic wall thickness by enhanced computed tomography

    International Nuclear Information System (INIS)

    Yokoyama, Kenichi; Takasu, Junichiro; Yamamoto, Rie; Taguchi, Rie; Itani, Yasutaka; Ito, Yuichi; Watanabe, Shigeru; Masuda, Yoshiaki

    2001-01-01

    The purpose of this study is to verify the usefulness of the quantification of aortic wall involvement by enhanced computed tomography (CT). One-hundred thirteen Japanese patients underwent two enhanced CT of the descending thoracic aorta at intervals. We sliced the descending thoracic aorta continuously from the level of the tracheal bifurcation with 1 cm intervals, and we defined aortic wall volume (AWV) (cm 3 ) as the sum of a 7-slice area of aortic wall involving calcification. The average of AWV increased from 7.95±2.92 cm 3 to 8.70±2.98 cm 3 . The developmental rate of AWV (ΔAWV) was 0.270±0.281 cm 3 /year. ΔAWV did not have a significant correlation with any risk factor at the baseline. ΔAWV had significant correlation with total cholesterol, (LDL-C) low-density lipoprotein cholesterol and LDL-C/(HDL-C) high-density lipoprotein cholesterol ratio at the follow-up, and by multivariate analysis with only the LDL-C/HDL-C ratio. ΔAWV was not correlated with the intake status of hypoglycemic, antihypertensive or lipid-lowering drugs. The cut-off level of total cholesterol with the most significant odds ratio for progression of aortic wall was 190 mg/dl, and that of LDL-C was 130 mg/dl. This method proved to be useful for the non-invasive assessment of aortic wall thickness. (author)

  2. Impact of Discordant Views in the Management of Descending Thoracic Aortic Aneurysm.

    Science.gov (United States)

    Chiu, Peter; Sailer, Anna-Margaretha; Baiocchi, Michael; Goldstone, Andrew B; Schaffer, Justin M; Trojan, Jeff; Fleischmann, Dominik; Mitchell, R Scott; Miller, D Craig; Dake, Michael D; Woo, Y Joseph; Lee, Jason T; Fischbein, Michael P

    2017-01-01

    Thoracic endovascular aortic repair has a lower perceived risk than open surgical repair and has become an increasingly popular alternative. Whether general consensus exists regarding candidacy for either operation among open and endovascular specialists is unknown. A retrospective review of isolated descending thoracic aortic aneurysm at our institution between January 2005 and October 2015 was performed, excluding trauma and dissection. Two cardiac surgeons, 2 cardiovascular surgeons, 1 vascular surgeon, and 1 interventional radiologist gave their preference for open vs endovascular repair. Interobserver agreement was assessed with the kappa coefficient. k-means clustering agnostically grouped various patterns of agreement. The mean rating was predicted using least absolute shrinkage and selection operator regression. Negative binomial regression predicted the discrepancy between our panel of raters and the historical operation. Generalized estimating equation modeling was then used to evaluate the association between the extent of discrepancy and the adverse perioperative outcome. There were 77 patients with preoperative imaging studies. Pairwise interobserver agreement was only fair (median weighted kappa 0.270 [interquartile range 0.211-0.404]). Increasing age and proximal neck length predicted an increasing preference for thoracic endovascular aortic repair in our panel; larger proximal neck diameter predicted a general preference for open surgical repair. Increasing proximal neck diameter predicted a larger discrepancy between our panel and the historical operation. Greater discrepancy was associated with adverse outcome. Substantial disagreement existed among our panel, and an exploratory analysis of the effect of increasing discrepancy demonstrated an association with adverse perioperative outcome. An investigation of the effect of a thoracic aortic team with open and endovascular specialists is warranted. Copyright © 2017 Elsevier Inc. All rights

  3. Endovascular Treatment of Descending Thoracic Aortic Aneurysms with the EndoFit Stent-Graft

    International Nuclear Information System (INIS)

    Saratzis, N.; Saratzis, Athanasios; Melas, N.; Ginis, G.; Lioupis, A.; Lykopoulos, D.; Lazaridis, J.; Kiskinis, Dimitrios

    2007-01-01

    Objective. To evaluate the mid-term feasibility, efficacy, and durability of descending thoracic aortic aneurysm (DTAA) exclusion using the EndoFit device (LeMaitre Vascular). Methods. Twenty-three (23) men (mean age 66 years) with a DTAA were admitted to our department for endovascular repair (21 were ASA III+ and 2 refused open repair) from January 2003 to July 2005. Results. Complete aneurysm exclusion was feasible in all subjects (100% technical success). The median follow-up was 18 months (range 8-40 months). A single stent-graft was used in 6 cases. The deployment of a second stent-graft was required in the remaining 17 patients. All endografts were attached proximally, beyond the left subclavian artery, leaving the aortic arch branches intact. No procedure-related deaths have occurred. A distal type I endoleak was detected in 2 cases on the 1 month follow-up CT scan, and was repaired with reintervention and deployment of an extension graft. A nonfatal acute myocardial infarction occurred in 1 patient in the sixth postoperative month. Graft migration, graft infection, paraplegia, cerebral or distal embolization, renal impairment or any other major complications were not observed. Conclusion. The treatment of DTAAs using the EndoFit stent-graft is technically feasible. Mid-term results in this series are promising

  4. Contemporary economic and clinical evaluations of endovascular repair for intact descending thoracic aortic aneurysms.

    Science.gov (United States)

    Silingardi, Roberto; Gennai, Stefano; Coppi, Giovanni; Chester, Johanna; Marcheselli, Luigi; Brunetti, Massimo

    2017-12-01

    The aim of this study was to assess clinical and contemporary costs associated with elective endovascular repair of intact descending thoracic aortic aneurysms (DTAA) into the mid-term follow-up. A retrospective review of a prospectively maintained clinical database including 29 consecutive patients from July 2005 to December 2009 treated with elective endovascular repair (TEVAR) or TEVAR and surgical infrarenal repair (hybrid) of intact DTAA was performed. Mean age was 74.5 years old (±7.1). Primary clinical endpoints include mortality and major morbidity. Additionally a comprehensive economic appraisal of individual in-hospital and follow-up costs was executed. Economic endpoints include in-hospital and follow-up costs and patient discharge status. Elective endovascular and open repairs' clinical and economical outcomes in contemporary literature were assessed for comparison according to PRISMA standards. Immediate mortality was 6.9% (1/24 TEVAR and 1/5 hybrid). Three respiratory complications were recorded (11%; 2 TEVAR, 1 hybrid). Renal and cardiac complication rates were 7.4% (1 TEVAR, 1 hybrid) and 3.7% (1 TEVAR) respectively. Routine discharge home was achieved for 85% of patients (95.7% TEVAR, 25% hybrid). Three endoleaks were treated throughout the follow-up (2 TEVAR, 1 hybrid; mean 30.4 mo, ±19.9) rendering an 11% (3/27) reintervention rate. Average immediate cost was €21,976.87 for elective endovascular repair and €33,783.21 for elective endovascular hybrid repair. Additional reintervention and routine follow-up costs augmented immediate costs by 12.4%. This study supports satisfying immediate clinical outcomes for TEVAR and TEVAR+surgical infrarenal procedures. Although limited by a small population size and difficulties in economic comparisons, this study presents the real world social and economic cost scenario for both elective TEVAR and TEVAR hybrid treatment of DTAA of both the in-hospital and at mid term follow-up periods.

  5. Celiac Trunk Embolization, as a Means of Elongating Short Distal Descending Thoracic Aortic Aneurysm Necks, Prior to Endovascular Aortic Repair

    International Nuclear Information System (INIS)

    Belenky, Alexander; Haddad, Menashe; Idov, Igor; Knizhnik, Michael; Litvin, Sergey; Bachar, Gil N.; Atar, Eli

    2009-01-01

    The purpose of this study was to report our experience in elongating short distal necks of descending thoracic aortic aneurysms (DTAAs) by coil embolization of the celiac trunk prior to endovascular aneurysm repair (EVAR). During 6 years seven patients (five men and two women; mean age, 74) who had DTAAs with short distal necks unsuitable for conventional EVAR, and well patent superior and inferior mesenteric arteries based on CT, were treated in one session with EVAR after the celiac trunk was coil embolized to elongate the neck. All patients were followed by CT every 3 months in the first year and every 6 months thereafter. Technical success was achieved in all patients, and no early or late ischemic complications were noted. No procedural complications occurred and good aneurysm sealing was obtained in all patients. Three endoleaks were identified after 3 months (one patient) and 6 months (two patients); all were treated successfully with insertion of an additional stent-graft. In patients with DTAAs who are candidates for EVAR but have short aneurysm distal necks, celiac trunk embolization-only if the superior and inferior mesenteric arteries are patent-is a good and safe way to elongate the neck and enable EVAR.

  6. Descending aortic injury by a thoracic pedicle screw during posterior reconstructive surgery: a case report.

    Science.gov (United States)

    Watanabe, Kei; Yamazaki, Akiyoshi; Hirano, Toru; Izumi, Tomohiro; Sano, Atsuki; Morita, Osamu; Kikuchi, Ren; Ito, Takui

    2010-09-15

    Case report. To describe an iatrogenic aortic injury by pedicle screw instrumentation during posterior reconstructive surgery of spinal deformity. Iatrogenic major vascular injuries during anterior instrumentation procedures have been reported by several authors, but there have been few reports regarding iatrogenic major vascular injuries during posterior instrumentation procedures. A 57-year-old woman with thoracolumbar kyphosis due to osteoporotic T12 vertebral fracture underwent posterior correction and fusion (T10-L2), using segmental pedicle screw construct concomitant with T12 pedicle subtraction osteotomy. Postoperative routine plain radiographs and computed tomography myelography demonstrated a misplaced left T10 pedicle screw, which was in contact with the posteromedial aspect of the thoracic aorta, and suspected penetration of the aortic wall. The patient underwent removal of the pedicle screw, and repair of the penetrated aortic wall through a simultaneous anterior-posterior approach. The patient tolerated the procedure well without neurologic sequelae, and was discharged several days after removal of a left tube thoracostomy. Plain radiographs demonstrated solid fusion at the osteotomy site and no loosening of hardware. Preoperative neurologic symptoms improved completely at 18-months follow-up. Use of pedicle screw instrumentation has the potential to cause major vascular injury during posterior spinal surgery, and measures to prevent this complication must be taken. Timely diagnosis and treatment are essential to prevent both early and delayed complications and death.

  7. Mean blood velocities and flow impedance in the fetal descending thoracic aortic and common carotid artery in normal pregnancy.

    Science.gov (United States)

    Bilardo, C M; Campbell, S; Nicolaides, K H

    1988-12-01

    A linear array pulsed Doppler duplex scanner was used to establish reference ranges for mean blood velocities and flow impedance (Pulsatility Index = PI) in the descending thoracic aorta and in the common carotid artery from 70 fetuses in normal pregnancies at 17-42 weeks' gestation. The aortic velocity increased with gestation up to 32 weeks, then remained constant until term, when it decreased. In contrast, the velocity in the common carotid artery increased throughout pregnancy. The PI in the aorta remained constant throughout pregnancy, while in the common carotid artery it fell steeply after 32 weeks. These results suggest that with advancing gestation there is a redistribution of the fetal circulation with decreased impedance to flow to the fetal brain, presumably to compensate for the progressive decrease in fetal blood PO2.

  8. Physiologic Tolerance of Descending Thoracic Aortic Balloon Occlusion in a Swine Model of Hemorrhagic Shock

    Science.gov (United States)

    2013-01-10

    Endovascular proximal control of ruptured abdominal aortic aneurysms: the internal aortic clamp. J Cardiovasc Surg (Torino) 2009;50(3):381. 14. Arthurs Z...Starnes B, See C, Andersen C. Clamp Before You Cut: Proximal Control of Ruptured Abdominal Aortic Aneurysms Using Endovascular Balloon Occlusion

  9. Tratamento endovascular de ruptura traumática da aorta torácica descendente Endovascular treatment of traumatic descending thoracic aortic rupture

    Directory of Open Access Journals (Sweden)

    João Roberto Breda

    2007-06-01

    Full Text Available Paciente do sexo feminino, 55 anos de idade, vítima de atropelamento, foi admitida em unidade de emergência, onde se realizou o diagnóstico clínico, radiológico e tomográfico de ruptura traumática da aorta torácica descendente. Diante do achado, a paciente foi encaminhada para tratamento endovascular com colocação de endoprótese auto-expansível (stent pela artéria femoral. O tratamento obteve sucesso, evidenciado pela exclusão da lesão localizada previamente no istmo aórtico. O tratamento endovascular tem sido indicado nas afecções de aorta torácica descendente com bons resultados iniciais. Na ruptura traumática de aorta, a terapêutica endovascular representa uma alternativa aceitável, especialmente devido aos riscos do tratamento operatório convencional.A 55-year-old, female patient who was run over by a motor vehicle was admitted at an emergency room. Clinical, radiological and tomographic diagnosis of traumatic descending aortic thoracic rupture was performed. The patient was referred for endovascular treatment with placement of a self-expandable stent through the femoral artery. Treatment was successful, with exclusion of the lesion previously located in the aortic isthmus. Endovascular treatment has been indicated in the treatment of descending thoracic aortic diseases, with good initial results. In case of traumatic aortic rupture, endovascular treatment is a feasible alternative, especially due to risks offered by the conventional surgical treatment.

  10. Geometric Deformations of the Thoracic Aorta and Supra-Aortic Arch Branch Vessels Following Thoracic Endovascular Aortic Repair.

    Science.gov (United States)

    Ullery, Brant W; Suh, Ga-Young; Hirotsu, Kelsey; Zhu, David; Lee, Jason T; Dake, Michael D; Fleischmann, Dominik; Cheng, Christopher P

    2018-04-01

    To utilize 3-D modeling techniques to better characterize geometric deformations of the supra-aortic arch branch vessels and descending thoracic aorta after thoracic endovascular aortic repair. Eighteen patients underwent endovascular repair of either type B aortic dissection (n = 10) or thoracic aortic aneurysm (n = 8). Computed tomography angiography was obtained pre- and postprocedure, and 3-D geometric models of the aorta and supra-aortic branch vessels were constructed. Branch angle of the supra-aortic branch vessels and curvature metrics of the ascending aorta, aortic arch, and stented thoracic aortic lumen were calculated both at pre- and postintervention. The left common carotid artery branch angle was lower than the left subclavian artery angles preintervention ( P Supra-aortic branch vessel angulation remains relatively static when proximal landing zones are distal to the left common carotid artery.

  11. Dissection of Retroesophageal Aortic Diverticulum and Descending Aorta in a Patient with Right Aortic Arch: Magnetic Resonance Demonstration

    International Nuclear Information System (INIS)

    Ko, S.-F.; Ng, S.-H.; Fu, Morgan; Lo, P.-H.; Cheng, Y.-F.; Lee, T.-Y.

    1996-01-01

    An acute aortic dissection involved the retroesophageal aortic diverticulum (RAD) and descending thoracic aorta in a patient with right aortic arch. The RAD, which was separated into false and true lumens by an intimal flap-the classic diagnostic sign of aortic dissection-was overlooked on transesophageal echocardiography and computed tomography but was clearly depicted on magnetic resonance imaging (MRI). It was found that MRI can delineate the anatomy of a congenital arch anomaly complicated by great vessels disease

  12. Hybrid Approach of Aortic Diseases: Zone 1 Delivery and Volumetric Analysis on the Descending Aorta

    Directory of Open Access Journals (Sweden)

    José Augusto Duncan

    Full Text Available Abstract Introduction: Conventional techniques of surgical correction of arch and descending aortic diseases remains as high-risk procedures. Endovascular treatments of abdominal and descending thoracic aorta have lower surgical risk. Evolution of both techniques - open debranching of the arch and endovascular approach of the descending aorta - may extend a less invasive endovascular treatment for a more extensive disease with necessity of proximal landing zone in the arch. Objective: To evaluate descending thoracic aortic remodeling by means of volumetric analysis after hybrid approach of aortic arch debranching and stenting the descending aorta. Methods: Retrospective review of seven consecutive patients treated between September 2014 and August 2016 for diseases of proximal descending aorta (aneurysms and dissections by hybrid approach to deliver the endograft at zone 1. Computed tomography angiography were analyzed using a specific software to calculate descending thoracic aorta volumes pre- and postoperatively. Results: Follow-up was done in 100% of patients with a median time of 321 days (range, 41-625 days. No deaths or permanent neurological complications were observed. There were no endoleaks or stent migrations. Freedom from reintervention was 100% at 300 days and 66% at 600 days. Median volume reduction was of 45.5 cm3, representing a median volume shrinkage by 9.3%. Conclusion: Hybrid approach of arch and descending thoracic aorta diseases is feasible and leads to a favorable aortic remodeling with significant volume reduction.

  13. Pathogenetic Basis of Aortopathy and Aortic Valve Disease

    Science.gov (United States)

    2018-02-19

    Aortopathies; Thoracic Aortic Aneurysm; Aortic Valve Disease; Thoracic Aortic Disease; Thoracic Aortic Dissection; Thoracic Aortic Rupture; Ascending Aortic Disease; Descending Aortic Disease; Ascending Aortic Aneurysm; Descending Aortic Aneurysm; Marfan Syndrome; Loeys-Dietz Syndrome; Ehlers-Danlos Syndrome; Shprintzen-Goldberg Syndrome; Turner Syndrome; PHACE Syndrome; Autosomal Recessive Cutis Laxa; Congenital Contractural Arachnodactyly; Arterial Tortuosity Syndrome

  14. Thoracic aortic aneurysms and dissections: endovascular treatment.

    Science.gov (United States)

    Baril, Donald T; Cho, Jae S; Chaer, Rabih A; Makaroun, Michel S

    2010-01-01

    The treatment of thoracic aortic disease has changed radically with the advances made in endovascular therapy since the concept of thoracic endovascular aortic repair was first described 15 years ago. Currently, there is a diverse array of endografts that are commercially available to treat the thoracic aorta. Multiple studies, including industry-sponsored and single-institution reports, have demonstrated excellent outcomes of thoracic endovascular aortic repair for the treatment of thoracic aortic aneurysms, with less reported perioperative morbidity and mortality in comparison with conventional open repair. Additionally, similar outcomes have been demonstrated for the treatment of type B dissections. However, the technology remains relatively novel, and larger studies with longer term outcomes are necessary to more fully evaluate the role of endovascular therapy for the treatment of thoracic aortic disease. This review examines the currently available thoracic endografts, preoperative planning for thoracic endovascular aortic repair, and outcomes of thoracic endovascular aortic repair for the treatment of both thoracic aortic aneurysms and type B aortic dissections. Mt Sinai J Med 77:256-269, 2010. (c) 2010 Mount Sinai School of Medicine.

  15. A History of Thoracic Aortic Surgery.

    Science.gov (United States)

    McFadden, Paul Michael; Wiggins, Luke M; Boys, Joshua A

    2017-08-01

    Ancient historical texts describe the presence of aortic pathology conditions, although the surgical treatment of thoracic aortic disease remained insurmountable until the 19th century. Surgical treatment of thoracic aortic disease then progressed along with advances in surgical technique, conduit production, cardiopulmonary bypass, and endovascular technology. Despite radical advances in aortic surgery, principles established by surgical pioneers of the 19th century hold firm to this day. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Imaging of thoracic aortic dissection

    International Nuclear Information System (INIS)

    Vu, F.H.; Young, N.; Soo, Y.S.

    1994-01-01

    Acute thoracic aortic dissection has a high mortality rate if untreated, so the diagnosis must be rapidly made. Multiple imaging techniques are often used. This retrospective study from 1988 to 1993 assesses the usefulness in diagnosis of chest X-rays, computed tomography (CT) scanning, aortography, magnetic resonance imaging (MRI), trans-thoracic (TTE) and trans-oesophageal (TOE) echocardiography. Forty-two patients with a final clinical diagnosis of dissection were studied. The diagnosis was confirmed in 16 (13 at surgery and three at autopsy). Three died with dissection given as the only cause of death. Chest X-ray abnormalities were seen in all 19 patients with surgery or death from dissection, with a widened mediastinum and/or dilated aorta being present in 17. In the group of 16 patients with surgery or autopsy proof, CT scans found dissections in 9 out of 12 patients studied and correctly classified the type in only five. Aortography was preformed in five, with accurate depiction of dissection and type in all. TTE found dissections in three of eight patients imaged by this method. MRI and TOE were preformed each on two patients, with accurate depiction of dissection and type in each. Because of the relatively low sensitivity of CT scanning in defining aortic dissections Westmead Hospital is currently assessing the use of TOE as the prime imaging modality prior to surgical intervention. 17 refs., 4 tabs., 4 figs

  17. Descending thoracic aorta dissection associated with esophageal carcinoma

    Directory of Open Access Journals (Sweden)

    Kaushik Saha

    2013-01-01

    Full Text Available The association of aortic dissection with a malignancy is a rare finding and previous reports are usually those of primary aortic sarcomas. A 45-year-old male presented to us with chest pain and dysphagia for 1 month with a background history of obstructive airway disease and uncontrolled hypertension. In this report we present a case of typical descending aorta dissection with associated esophageal carcinoma.

  18. Acute Type II Aortic Dissection with Severe Aortic Regurgitation and Chronic Descending Aortic Dissection in Pregnant Patient with Marfan Syndrome.

    Science.gov (United States)

    Lee, Seok-Soo; Jung, Tae-Eun; Lee, Dong Hyup

    2012-12-01

    Aortic dilatation and dissection are severe complications during pregnancy that can be fatal to both the mother and the fetus. The risks of these complications are especially high in pregnant patients with Marfan syndrome; however, incidents of descending aortic dissection are very rare. This case report involves a successful Bentall procedure for and recovery from a rare aortic dissection in a pregnant Marfan patient who developed acute type II aortic dissection with severe aortic regurgitation and chronic descending aortic dissection immediately after Cesarean section. Regular follow-up will be needed to monitor the descending aortic dissection.

  19. Aneurysm growth after late conversion of thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Hirofumi Kasahara

    2015-01-01

    Full Text Available A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four sequential computed tomography scans demonstrated that the aneurysm was additionally increasing in size probably due to continuous hematoma production, suggesting a possibility of endoleaks. This case demonstrates the importance of careful radiologic surveillance after endovascular repair, and also after partial open conversion.

  20. JAG Tearing Technique with Radiofrequency Guide Wire for Aortic Fenestration in Thoracic Endovascular Aneurysm Repair

    International Nuclear Information System (INIS)

    Ricci, Carmelo; Ceccherini, Claudio; Leonini, Sara; Cini, Marco; Vigni, Francesco; Neri, Eugenio; Tucci, Enrico; Benvenuti, Antonio; Tommasino, Giulio; Sassi, Carlo

    2012-01-01

    An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.

  1. [Thoracic aortic dissection revealed by systemic cholesterol embolism].

    Science.gov (United States)

    Braem, L; Paule, P; Héno, P; Morand, J J; Mafart, B; La Folie, T; Varlet, P; Mioulet, D; Fourcade, L

    2006-10-01

    Systemic cholesterol embolism is a rare complication of atherosclerosis, and has various presentations. Arterial catheterisms are a common cause. However, the association with an aortic dissection has been exceptionally reported. We report the observation of a 70 year-old man, with coronary artery disease, hypertension, diabetes and dyslipidemia. Six months before hospitalization, a coronary angioplasty was performed due to recurrent angina. The association of purpuric lesions on the feet, with acute renal failure confirmed cholesterol embolism syndrome. Transoesophageal echocardiography showed a dissection of the descending thoracic aorta associated with complex atheroma. The evolution was marked by the pulpar necrosis of a toe and by a worsening of the renal failure, requiring definitive hemodialysis. Further echographic control highlighted the rupture of the intimal veil of the dissection. Cholesterol embolism syndrome may reveal an aortic dissection in patients without thoracic symptoms. In such cases, transoesophageal echocardiography is a useful and non-invasive examination.

  2. Acute Type II Aortic Dissection with Severe Aortic Regurgitation and Chronic Descending Aortic Dissection in Pregnant Patient with Marfan Syndrome

    OpenAIRE

    Lee, Seok-Soo; Jung, Tae-Eun; Lee, Dong Hyup

    2012-01-01

    Aortic dilatation and dissection are severe complications during pregnancy that can be fatal to both the mother and the fetus. The risks of these complications are especially high in pregnant patients with Marfan syndrome; however, incidents of descending aortic dissection are very rare. This case report involves a successful Bentall procedure for and recovery from a rare aortic dissection in a pregnant Marfan patient who developed acute type II aortic dissection with severe aortic regurgitat...

  3. Endovascular stent-graft management of thoracic aortic diseases

    International Nuclear Information System (INIS)

    Dake, Michael D.

    2001-01-01

    The traditional standard therapy for descending thoracic aortic aneurysm (TAA) is open operative repair with graft replacement of the diseased aortic segment. Despite important advances in surgical techniques, anesthetic management, and post-operative care over the last 30 years, the mortality and morbidity of surgery remains considerable, especially in patients at high risk for thoracotomy because of coexisting severe cardiopulmonary abnormalities or other medical diseases. The advent of endovascular stent-graft technology provides an alternative to open surgery for selected patients with TAA. The initial experience suggests that stent-graft therapy potentially may reduce the operative risk, hospital stay and procedural expenses of TAA repair. These potential benefits are especially attractive for patients at high risk for open TAA repair. Current results of endovascular TAA therapy document operative mortalities of between 0 and 4%, aneurysm thrombosis in 90 and 100% of cases, and paraplegia as a complication in 0 and 1.6% of patients. The early success of stent-graft repair of TAA has fostered the application of these devices for the management of a wide variety of thoracic aortic pathologies, including acute and chronic dissection, intramural hematoma, penetrating ulcer, traumatic injuries, and other diseases. The results of prospective controlled trials that compare the outcomes of stent-graft therapy with those of surgical treatment in patients with specific types of aortic disease are anxiously awaited before recommendations regarding the general use of these new devices can be made with confidence

  4. Bovine aortic arch: A novel association with thoracic aortic dilation

    International Nuclear Information System (INIS)

    Malone, C.D.; Urbania, T.H.; Crook, S.E.S.; Hope, M.D.

    2012-01-01

    Aim: To investigate whether there is a link between bovine arch and thoracic aortic aneurysm. Materials and methods: Computed tomography (CT) and magnetic resonance imaging (MRI) images of the thorax of 191 patients with dilated thoracic aortas and 391 consecutive, unselected patients as controls were retrospectively reviewed. Bovine arch was considered present if either a shared origin of the left common carotid and innominate arteries or an origin of the left common carotid from the innominate artery was identified. A chi-square test was used to evaluate the significance of differences between subgroups. Results: A trend towards increased prevalence of bovine arch was seen in patients with dilated aortas (26.2%) compared to controls (20.5%, p = 0.12). The association was statistically significant in patients over 70 years old (31.9%, p = 0.019) and when dilation involved the aortic arch (47.6%, p = 0.003). Conclusions: An association between bovine arch and aortic dilation is seen in older patients, and when dilation involves the aortic arch. Bovine arch should be considered a potential risk factor for thoracic aortic aneurysm.

  5. Endovascular treatment of thoracic aortic pseudoaneurysm due to brucellosis: a rare case report.

    Science.gov (United States)

    Wang, Shuai; Wang, Qi; Liu, Han; Sun, Siqiao; Sun, Xiwei; Zhang, Yang; Wang, Zhongying; Cheng, Zhihua

    2017-06-02

    Arterial damage is a known complication of brucellosis, but the occurrence of a thoracic aortic pseudoaneurysm secondary to brucellosis has not been previously reported. A 65-year-old Chinese man presented with a pseudoaneurysm in the descending segment of the thoracic aorta that caused symptoms of chest pain and intermittent fever. He was diagnosed with a thoracic aortic pseudoaneurysm secondary to brucellosis based on a positive brucella serology test (standard-tube agglutination test) and imaging examination (computed tomography angiography). Anti-brucellosis treatment and covered stent graft implantation were attempted to eliminate the brucellosis and pseudoaneurysm, respectively, and were ultimately successful, with no symptoms after 6 months of follow-up. Endovascular repair may be effective and safe for treating a thoracic aortic pseudoaneurysm resulting from brucellosis.

  6. Penetrating Atherosclerotic Ulcer of the Descending Thoracic Aorta: Treatment by Endovascular Stent-Graft

    International Nuclear Information System (INIS)

    Murgo, Salvatore; Dussaussois, Luc; Golzarian, Jafar; Cavenaile, Jean Christophe; Abada, Hicham Tarik; Ferreira, Jose; Struyven, Julien

    1998-01-01

    Purpose: To present four cases of penetrating ulcer of the descending thoracic aorta treated by transfemoral insertion of an endoluminal stent-graft. Methods: Four patients with penetrating aortic ulcers were reviewed. Three cases were complicated by rupture, false aneurysm, or retrograde dissection. All patients were treated by endovascular stent-graft and were followed by helical computed tomography (CT). Results: Endovascular stent-graft deployment was successful in all patients. However, in one case we observed a perigraft leak that spontaneously disappeared within the first month, and two interventions were needed for another patient. Following treatment, one episode of transient spinal ischemia was observed. The 30-day survival rate was 100%, but one patient died from pneumonia with cardiac failure 34 days after the procedure. In one patient, helical CT performed at 3 months showed a false aneurysm independent of the first ulcer. This patient refused any further treatment and suddenly died at home (unknown cause) after a 6-month follow-up period. Conclusion: Transluminal placement of endovascular stent-grafts for treatment of penetrating ulcers of the descending thoracic aorta appears to be a possible alternative to classical surgery. After treatment, follow-up by CT is essential to detect possible complications of the disease

  7. Wall stress on ascending thoracic aortic aneurysms with bicuspid compared with tricuspid aortic valve.

    Science.gov (United States)

    Xuan, Yue; Wang, Zhongjie; Liu, Raymond; Haraldsson, Henrik; Hope, Michael D; Saloner, David A; Guccione, Julius M; Ge, Liang; Tseng, Elaine

    2018-03-08

    Guidelines for repair of bicuspid aortic valve-associated ascending thoracic aortic aneurysms have been changing, most recently to the same criteria as tricuspid aortic valve-ascending thoracic aortic aneurysms. Rupture/dissection occurs when wall stress exceeds wall strength. Recent studies suggest similar strength of bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms; thus, comparative wall stress may better predict dissection in bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms. Our aim was to determine whether bicuspid aortic valve-ascending thoracic aortic aneurysms had higher wall stresses than their tricuspid aortic valve counterparts. Patients with bicuspid aortic valve- and tricuspid aortic valve-ascending thoracic aortic aneurysms (bicuspid aortic valve = 17, tricuspid aortic valve = 19) greater than 4.5 cm underwent electrocardiogram-gated computed tomography angiography. Patient-specific 3-dimensional geometry was reconstructed and loaded to systemic pressure after accounting for prestress geometry. Finite element analyses were performed using the LS-DYNA solver (LSTC Inc, Livermore, Calif) with user-defined fiber-embedded material model to determine ascending thoracic aortic aneurysm wall stress. Bicuspid aortic valve-ascending thoracic aortic aneurysms 99th-percentile longitudinal stresses were 280 kPa versus 242 kPa (P = .028) for tricuspid aortic valve-ascending thoracic aortic aneurysms in systole. These stresses did not correlate to diameter for bicuspid aortic valve-ascending thoracic aortic aneurysms (r = -0.004) but had better correlation to tricuspid aortic valve-ascending thoracic aortic aneurysms diameter (r = 0.677). Longitudinal stresses on sinotubular junction were significantly higher in bicuspid aortic valve-ascending thoracic aortic aneurysms than in tricuspid aortic valve-ascending thoracic aortic aneurysms (405 vs 329 kPa, P = .023). Bicuspid

  8. Factors influencing the mechanical behaviour of healthy human descending thoracic aorta

    International Nuclear Information System (INIS)

    Guinea, Gustavo V; Atienza, José M; Rojo, Francisco J; Yiqun, Li; Claes, Els; Elices, Manuel; García-Herrera, Claudio M; Goicolea, José M; García-Montero, Carlos; Burgos, Raúl L; Goicolea, Francisco J

    2010-01-01

    In recent times, significant effort has been made to understand the mechanical behaviour of the arterial wall and how it is affected by the different vascular pathologies. However, to be able to interpret the results correctly, it is essential that the influence of other factors, such as aging or anisotropy, be understood. Knowledge of mechanical behaviour of the aorta has been customarily constrained by lack of data on fresh aortic tissue, especially from healthy young individuals. In addition, information regarding the point of rupture is also very limited. In this study, the mechanical behaviour of the descending thoracic aorta of 28 organ donors with no apparent disease, whose ages vary from 17 to 60 years, is evaluated. Tensile tests up to rupture are carried out to evaluate the influence of age and wall anisotropy. Results reveal that the tensile strength and stretch at failure of healthy descending aortas show a significant reduction with age, falling abruptly beyond the age of 30. This fact places age as a key factor when mechanical properties of descending aorta are considered

  9. Thoracic aortic coarctation: MR evaluation and follow-up

    International Nuclear Information System (INIS)

    Papavero, R.; Kastler, B.; Clair, C.; Livolsi, A.; Papavero, R.; Site, O.; Kastler, B.; Clair, C.; Litzler, J.F.; Delabrousse, E.; Scheneider, P.; Bernard, Y.

    2001-01-01

    Purpose: Report our experience in the evaluation and follow-up of thoracic aortic coarctation with MRI and describe its role to estimate trans-stenotic flow. Material and methods: 43 MR examinations were performed in 30 patients (age range 15 days to 73 years) referred to our institution in the last 7 years. Results: MRI visualized the ascending, horizontal and descending portions of the aorta and the supra-aortic vessels in 42/43 patients. MRI clearly identified preoperatively an aortic coarctation in 11/12 cases confirmed by surgery. Postoperatively MRI depicted 4 restenosis and one aneurysm. In 5 patients MRI demonstrated pseudo-coarctation. A significant correlation was established between the maximal trans-stenotic pressure gradient when measured by Doppler US or angiography and the size of the signal void measured on cine-MR images (r=0.72; p<0.01). Conclusion: MRI is a reliable non invasive investigation method for the diagnosis and semi-quantitative evaluation of aortic coarctation particularly when colour Doppler US is not satisfactory. (authors)

  10. Endovascular repair of traumatic thoracic aortic tears.

    Science.gov (United States)

    Mansour, M Ashraf; Kirk, Jeffrey S; Cuff, Robert F; Banegas, Shonda L; Ambrosi, Gavin M; Liao, Timothy H; Chambers, Christopher M; Wong, Peter Y; Heiser, John C

    2012-03-01

    Patients with thoracic aorta injuries (TAI) present a unique challenge. The purpose of this study was to review the outcomes of thoracic endovascular aortic repair (TEVAR) in patients with TAI. A retrospective chart review of all patients admitted for TEVAR for trauma was performed. In a 5-year period, 19 patients (6 women and 13 men; average age, 42 y) were admitted to our trauma center with TAI. Mechanism of injury was a motor vehicle crash in 12 patients, motorcycle crash in 2 patients, automobile-pedestrian accident in 2 patients, 1 fall, 1 crush injury, and 1 stab wound to the back. A thoracic endograft was used in 6 patients and proximal aortic cuffs were used in 13 patients (68%). One patient (5%) died. There were no strokes, myocardial infarctions, paraplegia, or renal failure. TEVAR for TAI appears to be a safe option for patients with multiple injuries. TEVAR in young patients is still controversial because long-term endograft behavior is unknown. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Mural Thrombus in the Normal-Appearing Descending Thoracic Aorta of a Chronic Smoker

    Science.gov (United States)

    Habib, Habib; Hsu, Judy; Winchell, Patricia Jo; Daoko, Joseph

    2013-01-01

    Thrombus formation in an atherosclerotic or aneurysmal descending thoracic aorta is a well-described, frequently encountered vascular condition. In comparison, thrombus formation in a normal-appearing descending thoracic aorta is reported far less often. We describe the case of a 46-year-old woman who had splenic and renal infarctions secondary to embolic showers from a large, mobile thrombus in a morphologically normal proximal descending thoracic aorta. After the patient underwent anticoagulation, stent-grafting, and surgical bypass to correct an arterial blockage caused by the stent-graft, she resumed a relatively normal life. In contrast with other cases of a thrombotic but normal-appearing descending thoracic aorta, this patient had no known malignancy or systemic coagulative disorders; her sole risk factor was chronic smoking. We discuss our patient's case and review the relevant medical literature, focusing on the effect of smoking on coagulation physiology. PMID:24391341

  12. Aortic dose constraints when reirradiating thoracic tumors

    International Nuclear Information System (INIS)

    Evans, Jaden D.; Gomez, Daniel R.; Amini, Arya; Rebueno, Neal; Allen, Pamela K.; Martel, Mary K.; Rineer, Justin M.; Ang, Kie Kian; McAvoy, Sarah; Cox, James D.; Komaki, Ritsuko; Welsh, James W.

    2013-01-01

    Background and purpose: Improved radiation delivery and planning has allowed, in some instances, for the retreatment of thoracic tumors. We investigated the dose limits of the aorta wherein grade 5 aortic toxicity was observed after reirradiation of lung tumors. Material and methods: In a retrospective analysis, 35 patients were identified, between 1993 and 2008, who received two rounds of external beam irradiation that included the aorta in the radiation fields of both the initial and retreatment plans. We determined the maximum cumulative dose to 1 cm 3 of the aorta (the composite dose) for each patient, normalized these doses to 1.8 Gy/fraction, and corrected them for long-term tissue recovery between treatments (NID R ). Results: The median time interval between treatments was 30 months (range, 1–185 months). The median follow-up of patients alive at analysis was 42 months (range, 14–70 months). Two of the 35 patients (6%) were identified as having grade 5 aortic toxicities. There was a 25% rate of grade 5 aortic toxicity for patients receiving composite doses ⩾120.0 Gy (vs. 0% for patients receiving R ⩾90.0 Gy) to 1 cm 3 of the aorta

  13. Outcomes of endovascular management of acute thoracic aortic emergencies in an academic level 1 trauma center.

    Science.gov (United States)

    Echeverria, Angela B; Branco, Bernardino C; Goshima, Kay R; Hughes, John D; Mills, Joseph L

    2014-12-01

    Thoracic aortic emergencies account for 10% of thoracic-related admissions in the United States and remain associated with high morbidity and mortality rates. Open repair has declined owing to the emergence of thoracic endovascular aortic repair (TEVAR), but data on emergency TEVAR use for acute aortic pathology remain limited. We therefore reviewed our experience. We retrospectively evaluated emergency descending thoracic aortic endovascular interventions performed at a single academic level 1 trauma center between January 2005 and August 2013 including all cases of traumatic aortic injury, ruptured descending thoracic aneurysm, penetrating atherosclerotic ulcer, aortoenteric fistula, and acute complicated type B dissection. Demographics, clinical data, and outcomes were extracted. Stepwise logistic regression was used to identify independent risk factors for death. During the study period, 51 patients underwent TEVAR; 22 cases (43.1%) were performed emergently (11 patients [50.0%] traumatic aortic injury; 4 [18.2%] ruptured descending thoracic aneurysm; 4 [18.2%] complicated type B dissection; 2 [9.1%] penetrating aortic ulcer; and 1 [4.5%] aortoenteric fistula). Overall, 72.7% (n = 16) were male with a mean age of 54.8 ± 15.9 years. Nineteen patients (86.4%) required only a single TEVAR procedure, whereas 2 (9.1%) required additional endovascular therapy, and 1 (4.5%) open thoracotomy. Four traumatic aortic injury patients required exploratory laparotomy for concomitant intra-abdominal injuries. During a mean hospital length of stay of 18.9 days (range, 1 to 76 days), 3 patients (13.6%) developed major complications. In-hospital mortality was 27.2%, consisting of 6 deaths from traumatic brain injury (1); exsanguination in the operating room before repair could be achieved (2); bowel ischemia (1) and multisystem organ failure (1); and family withdrawal of care (1). A stepwise logistic regression model identified 24-hour packed red blood cell requirements ≥4

  14. Medical image of the week: atherosclerotic aneurysm of aortic arch and descecnding thoracic aorta

    Directory of Open Access Journals (Sweden)

    Parasram M

    2016-02-01

    Full Text Available No abstract available. Article truncated after 150 words. A 94-year-old Spanish-speaking woman presented to the hospital with intermittent episodes of dyspnea and abdominal pain for one week. Her past medical history was notable for 30 pack-year smoking history and hypertension, which was reportedly controlled with medical therapy. Physical exam showed trace peripheral edema bilaterally, intact peripheral pulses, and a mild abdominal bruit. Work up at the emergency department revealed a non-ST elevation myocardial infarction with troponin T of 0.34 ng/mL but no ST-wave abnormality on electrocardiography. Chest x-ray displayed an incidental thoracic aneurysm (Figure 1. Chest computed tomography with contrast demonstrated a continuous aneurysm of the aortic arch and descending thoracic aorta with diameters measuring 6.8 cm and 6 cm, respectively (Figure 2A and 2B. Eccentric thrombi are noted in the aortic arch and the descending aorta. Interestingly, the distal descending thoracic aorta curves as it transitions to the abdominal aorta, which is evidence of a tortuous descending ...

  15. Thoracic Endovascular Aortic Repair (TEVAR) in Proximal (Type A) Aortic Dissection: Ready for a Broader Application?

    OpenAIRE

    Nienaber, Christoph A.; Sakalihasan, Natzi; Clough, Rachel E.; Aboukoura, Mohamed; Mancuso, Enrico; Yeh, James S.M.; Defraigne, Jean-Olivier; Cheshire, Nick; Rosendahl, Ulrich Peter; Quarto, Cesare; Pepper, John

    2016-01-01

    ObjectiveThoracic endovascular aortic repair (TEVAR) has demonstrated encouraging results and is gaining increasing acceptance as a treatment option for aortic aneurysms and dissections. Yet, its role in managing proximal aortic pathologies is unknown - this is important because in proximal (Stanford type A) aortic dissections, 10-30% are not accepted for surgery, and 30-50% are technically amenable for TEVAR. We describe our case series of type A aortic dissections treated using TEVAR.Method...

  16. Endovascular stent-graft placement for the treatment of acute onset and chronic aortic dissections of the descending aorta (Short-term follow-up)

    International Nuclear Information System (INIS)

    Petrov, I; Jorgova, J.; Trendafilova, D.

    2004-01-01

    The leading cause of death for patients with surgically untreated thoracic aortic aneurysms is the rupture of the aneurysm. Almost one half of these patients are left to medical treatment assuming the risk of late rupture and aneurysm sac enlargement - the late surgical treatment of these patients is too risky and with poor results. On the other hand the emergent surgical treatment of these cases is related with relatively high mortality rate. Recently, thoracic aortic stent-grafting has emerged as a less traumatic alternative therapeutic modality for patients with thoracic aortic aneurysms and aortic dissections. The first case of stent implantation in a dissected descending aorta was performed in Bulgaria at 09.04.2003. Since then we implanted in 8 patients thoracic stent grafts, The mean age of the patients was 67.5 years. The primary success was 100%. One died on the second postoperative day by abdominal aorta rupture. No other complications were registered. The mean follow-up of 5 months proved to be uneventful and the control CT revealed efficacious sealing of the entry and false lumen thrombosis in all except one cases. We report our initial clinical experience of endovascular stent-graft repair for dissection of the descending aorta that is encouraging. These preliminary data suggest that endovascular stent-grafting is a viable treatment for acute onset and chronic aortic dissection type B

  17. Clinical Studies in Risk Stratification & Therapy of Thoracic Aortic Disease

    NARCIS (Netherlands)

    Kamman, AV

    2017-01-01

    For this thesis we aimed to summarize outcomes and optimal treatment modality for thoracic aortic disease, discuss new imaging techniques and improve the use of current imaging modalities. Furthermore, we aimed to improve risk stratification for uncomplicated type B aortic dissection (TBAD) and

  18. Endovascular repair of mycotic aneurysm of the descending thoracic aorta: diagnostic and therapeutic dilemmas-two case reports with 1-year follow-up.

    Science.gov (United States)

    Marjanovic, Ivan; Sarac, Momir; Tomic, Aleksandar; Bezmarevic, Mihailo

    2013-10-01

    A mycotic aneurysm of the thoracic aorta is a rare diagnosis with high mortality. We present two cases of endovascular reconstruction of mycotic descending thoracic aorta. Specific or nonspecific bacterial or other infectious agent in serial samples of blood, urine, cerebrospinal fluid, and pleural puncture was not detected in the first case, but we found in sputum sample Mycobacterium tuberculosis in the second patient. We empirically began by administering broad-spectrum intravenous antibiotics in the first case, with preoperative antibiotic prophylaxis and antituberculotic drugs therapy in the second case, and continued with the same medication for 4 months after endovascular repair. Control computed tomographic scans 6 months after reconstruction showed no endoleak in both patients. Repair of mycotic descending thoracic aortic aneurysms by endoluminal stent graft is reasonable alternative to open surgical intervention. A broad-spectrum antibiotic therapy has a high significance in the treatment of patients with mycotic aneurysm. Georg Thieme Verlag KG Stuttgart · New York.

  19. [Coarctation of the descending aorta. A rare form of connatal aortic stenosis].

    Science.gov (United States)

    Stammwitz, E; Schöttler, M; Brix, F; Poser, H L; Langkau, G; Yükseltan, I

    1983-07-01

    A clinical diagnosis of a coarctation of the aorta was made in a 17-year-old female hypertensive patient. Angiography revealed an atypical stenosis of the descending aorta which was surgically corrected. The causes of aortic stenoses are discussed.

  20. The thoracic aortography by Gd-DTPA enhanced ultrafast cine MR imaging. Assessment of thoracic aortic dilatation in aging and in patients with hypertension and aortic valve disease

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Kawai, Ichiyoshi; Saito, Takayuki; Kikkawa, Nobutada; Haiyama, Toru

    1995-01-01

    To assess the morphology of thoracic aorta, we had a trial of Gd-DTPA enhanced ultrafast cine MR imaging on the thoracic aorta. This method was provided with high quality thoracic aortogram during 15-20 seconds. In patients without hypertension and aortic valve disease, dimensions of ascending aorta and aortic arch were significantly correlated with aging. In patients with hypertension, dimensions of ascending aorta and aortic arch were significantly dilated. In patients with aortic valve disease, thoracic aorta was diffusely enlarged, especially in ascending aorta. Gd-DTPA enhanced ultrafact cine MR imaging was useful to assess the thoracic aortic anatomy and diseases. (author)

  1. Anesthetic management of descending thoracic aortobifemoral bypass for aortoiliac occlusive disease: Our experience

    Directory of Open Access Journals (Sweden)

    Anjum Saiyed

    2014-01-01

    Full Text Available Background: Complete obstruction of the abdominal aorta at the renal artery level is a difficult surgical problem. Aortic clamping and declamping can lead to profound haemodynamic changes, myocardial infarction, ventricular failure or even death may result. These complications are important challenges in anesthetic management of these patients. Methods :0 Between August, 2010 and April, 2012, descending thoracic aorta to femoral artery bypass grafting was used to revascularize lower limbs in 11 patients in our institute. The anesthetic management of these patients is described here. Epidural catheter placement was done in T 5-6 or T 6-7 space for post operative pain relief. Induction was done by, Inj. Glycopyrolate 0.2 mg, Inj. Fentanyl 5 μg/kg., Inj. Pentothal sodium 5 mg/kg, Inj. Rocuronium 0.9 mg/kg, IPPV done. Left sided double lumen tube was inserted, Maintenance of Anesthesia was done by O 2 + N 2 O (30:70. Increments of Vecuronium and Fentanyl were given Monitoring of Heart rate, arterial pressure, central venous pressure were continuously displayed. The available pharmacological agents were used when there is deviation of more than 15% from base line. Results: In our study, inspite of measures taken to control rise in blood pressure during aortic cross clamping, a rise of 90 mm of Hg in one patient and 60-80 mm of Hg in four patients was observed, which was managed by sodium nitropruside infusion. At the end of surgery seven patients were extubated on the operation table. In remaining four patients DLT was replaced by single lumen endotracheal tube and were shifted to ICU on IPPV. They weaned off gradually in 3-5 hours. In our series blood loss was 400 ml to 1000 ml. There was no mortality in the first 24 hours. Postoperative bleeding was reported in one case which was re-explored and stood well. Conclusion: The anesthetic technique during aortic surgery is directed at minimizing the hemodynamic effects of cross clamping in order to

  2. Predictive factors for cerebrovascular accidents after thoracic endovascular aortic repair.

    Science.gov (United States)

    Mariscalco, Giovanni; Piffaretti, Gabriele; Tozzi, Matteo; Bacuzzi, Alessandro; Carrafiello, Giampaolo; Sala, Andrea; Castelli, Patrizio

    2009-12-01

    Cerebrovascular accidents are devastating and worrisome complications after thoracic endovascular aortic repair. The aim of this study was to determine cerebrovascular accident predictors after thoracic endovascular aortic repair. Between January 2001 and June 2008, 76 patients treated with thoracic endovascular aortic repair were prospectively enrolled. The study cohort included 61 men; mean age was 65.4 +/- 16.8 years. All patients underwent a specific neurologic assessment on an hourly basis postoperatively to detect neurologic deficits. Cerebrovascular accidents were diagnosed on the basis of physical examination, tomography scan or magnetic resonance imaging, or autopsy. Cerebrovascular accidents occurred in 8 (10.5%) patients, including 4 transient ischemic attack and 4 major strokes. Four cases were observed within the first 24-hours. Multivariable analysis revealed that anatomic incompleteness of the Willis circle (odds ratio [OR] 17.19, 95% confidence interval [CI] 2.10 to 140.66), as well as the presence of coronary artery disease (OR 6.86, 95 CI% 1.18 to 40.05), were independently associated with postoperative cerebrovascular accident development. Overall hospital mortality was 9.2%, with no significant difference for patients hit by cerebrovascular accidents (25.0% vs 7.3%, p = 0.102). Preexisting coronary artery disease, reflecting a severe diseased aorta and anomalies of Willis circle are independent cerebrovascular accident predictors after thoracic endovascular aortic repair procedures. A careful evaluation of the arch vessels and cerebral vascularization should be mandatory for patients suitable for thoracic endovascular aortic repair.

  3. Dissecting aneurysm of arch and descending thoracic aorta presenting as a left sided hemorrhagic pleural effusion

    Directory of Open Access Journals (Sweden)

    Shamim Shelley

    2010-01-01

    Full Text Available The most common cause of massive hemorrhagic effusion is malignancy. Herein we present a case of dissecting aneurysm of descending thoracic aorta presenting initially with shortness of breath due to left sided massive pleural effusion. Effusion was hemorrhagic in nature with high hematocrit value. CT scan of thorax with CT angiogram was done and that revealed the diagnosis.

  4. Association Between Thoracic Aortic Disease and Inguinal Hernia

    OpenAIRE

    Olsson, Christian; Eriksson, Per; Franco?Cereceda, Anders

    2014-01-01

    Background The study hypothesis was that thoracic aortic disease (TAD) is associated with a higher?than?expected prevalence of inguinal hernia. Such an association has been reported for abdominal aortic aneurysm (AAA) and hernia. Unlike AAA, TAD is not necessarily detectable with clinical examination or ultrasound, and there are no population?based screening programs for TAD. Therefore, conditions associated with TAD, such as inguinal hernia, are of particular clinical relevance. Methods and ...

  5. [Change of paradigms in the surgical treatment of complex thoracic aortic disease].

    Science.gov (United States)

    Herold, Ulf; Tsagakis, Konstantinos; Kamler, Markus; Massoudy, Parwis; Assenmacher, Eva; Eggebrecht, Holger; Buck, Thomas; Jakob, Heinz

    2006-08-01

    One of the main issues in complex thoracic aortic disease, requiring the replacement of the ascending aorta, the entire aortic arch and the descending aorta, is the vast amount of surgery necessary to cure the patient. Though one-stage repair is feasible by a clamshell thoracotomy, the associated surgical trauma and perioperative morbidity limit this approach to younger patients only. Classic surgical repair consist of a two-stage strategy, whereby, in the first step, the ascending aorta and the aortic arch are replaced via a midline sternotomy. In the second step, via a lateral thoracotomy, the descending aorta is replaced. The two stages may sum up to a mortality of 20%; furthermore, the waiting period between the stages is associated with a mortality rate of 10% of its own. Additionally, the two-stage strategy has an inherent limitation, due to the comorbidity and advanced age of the majority of patients. Therefore, the second stage cannot be offered to up to 30% of patients. New developments and improvements in aortic surgery were introduced to overcome these shortcomings and to simplify the surgical repair. The "elephant trunk" principle, introduced by Borst et al. in 1983, was an important step to facilitate surgical repair, but still required the second step. With the introduction of endovascular repair of thoracic aortic disease with stent grafts implanted retrograde via the femoral artery, new therapeutic concepts emerged. In the late 1990s, two Japanese groups reported first trials to stabilize the free-floating "elephant trunk" prosthesis by implantation of nitinol stent grafts into the vascular graft. The applied devices were purely custom-made and nonstandardized. The availability of industrially made and CE-marked stent-graft devices raised the possibility to apply them in open aortic arch surgery. The experience with stent-graft devices implanted antegrade into the descending aorta (Medtronic Talent) was reported first by the Essen and the Vienna

  6. Midterm results of endovascular stent graft treatment for descending aortic aneurysms including high-risk patients

    Directory of Open Access Journals (Sweden)

    Gussmann, Andreas

    2006-04-01

    Full Text Available Methods: 21 patients (17 men, 4 women; mean age 66.1 years, range 29-90 years with 15 true aneurysms, and 6 type B-dissections were treated by implantation of a TalentTM Endoluminal Stentgraft System from February 2000 to July 2003. In 3 cases it was necessary to overstent the left subclavian artery, in 1 case to overstent the left common carotid. Results: 2 patients (9.5% died during the first 30 days (1 myocardial infarction, 1 pneumonia. Two patients (9.5% suffered from cerebral ischemia and needed revascularisation. No paraplegia, no stroke occurred. One endoleak required additional stenting. No patient needed conversion. Follow-up, average 25.4 months (range 0-39, was 100% complete. During this another two patients died of myocardial infarction i.e. 9.5% (the above mentioned endoleak, but no late migration were detected in the remaining patients. In all cases the graft lumen stayed patent. Conclusions: Treatment of descending thoracic aortic aneurysm with an endovascular approach has acceptable mortality and morbidity-rates even in high risk patients. Procedural overstenting of the subclavian artery requires subclavian revascularisation in a minority of cases.

  7. Relation of murine thoracic aortic structural and cellular changes with aging to passive and active mechanical properties.

    Science.gov (United States)

    Wheeler, Jason B; Mukherjee, Rupak; Stroud, Robert E; Jones, Jeffrey A; Ikonomidis, John S

    2015-02-25

    Maintenance of the structure and mechanical properties of the thoracic aorta contributes to aortic function and is dependent on the composition of the extracellular matrix and the cellular content within the aortic wall. Age-related alterations in the aorta include changes in cellular content and composition of the extracellular matrix; however, the precise roles of these age-related changes in altering aortic mechanical function are not well understood. Thoracic aortic rings from the descending segment were harvested from C57BL/6 mice aged 6 and 21 months. Thoracic aortic diameter and wall thickness were higher in the old mice. Cellular density was reduced in the medial layer of aortas from the old mice; concomitantly, collagen content was higher in old mice, but elastin content was similar between young and old mice. Stress relaxation, an index of compliance, was reduced in aortas from old mice and correlated with collagen fraction. Contractility of the aortic rings following potassium stimulation was reduced in old versus young mice. Furthermore, collagen gel contraction by aortic smooth muscle cells was reduced with age. These results demonstrate that numerous age-related structural changes occurred in the thoracic aorta and were related to alterations in mechanical properties. Aortic contractility decreased with age, likely because of a reduction in medial cell number in addition to a smooth muscle contractile deficit. Together, these unique findings provide evidence that the age-related changes in structure and mechanical function coalesce to provide an aortic substrate that may be predisposed to aortopathies. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  8. Volumetric analysis demonstrates that true and false lumen remodeling persists for 12 months after thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Ga-Young Suh, PhD

    2016-09-01

    Full Text Available A 62-year-old man underwent an elephant trunk procedure followed by thoracic endovascular aortic repair (TEVAR. Computed tomography angiography-based models were built to quantify volume of the whole aorta and true and false lumens preoperatively, before TEVAR, after TEVAR, and at follow-up at 3, 6, and 12 months. With TEVAR, descending aortic true lumen volume increased by 54%, then increased additionally by 60% during 12 months. The descending aortic false lumen volume regressed continuously for 12 months following TEVAR, with the most rapid rate from 6 to 12 months at 16 cm3/month. TEVAR immediately increased true lumen volume and continued to remodel the true and false lumens throughout the following 12 months.

  9. Diagnostic and therapy of acute thoracic aortic diseases; Diagnostik und Therapie akuter Erkrankungen der thorakalen Aorta

    Energy Technology Data Exchange (ETDEWEB)

    Schotten, Sebastian; Pitton, Michael B. [Universitaetsmedizin Mainz Univ. (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie

    2017-09-15

    Acute diseases of the thoracic aorta represent a relatively rare but life threatening spectrum of pathologies. The non-traumatic diseases are usually summarized by the term ''acute aortic syndrome''. A timely diagnosis and initiation of therapy are cornerstones for the patient outcome. CT has become the standard imaging procedure due do its widespread availability and excellent sensitivity. Furthermore, CT is able to discriminate the variants of acute aortic diseases and to detect the wide spectrum of complications. The volumetric CT dataset is also the basis for planning of interventional procedures. Open surgical repair still represents the standard of care for acute pathologies of the ascending aorta while endovascular therapy, due to minimally invasive character and good outcome, has replaced open surgery in most cases of complicated lesions of the descending aorta.

  10. Aortopulmonary Fistula Presenting without an Endoleak after Thoracic Endovascular Aortic Repair

    Directory of Open Access Journals (Sweden)

    Giacomo Sica

    2017-08-01

    Full Text Available Herein, we report the case of a 60-year-old man, a smoker with a history of arterial hypertension and diabetes mellitus. After computed tomography (CT for an episode of hemoptysis, the patient underwent elective thoracic endovascular aortic repair (TEVAR because of a degenerative aneurysm of the descending thoracic aorta. The area of perianeurysmal pulmonary atelectasis reported on the CT scan was not considered. Three months later, he developed an aortopulmonary fistula without endoleaks. Although TEVAR is a relatively safe procedure, no detail should be overlooked in the preoperative evaluation in order to avoid life-threatening complications. Further, the effectiveness and modality of prolonged antibiotic prophylaxis and/or preoperative respiratory physiotherapy should be assessed in such cases.

  11. Impact of Surgical Stroke on the Early and Late Outcomes After Thoracic Aortic Operations.

    Science.gov (United States)

    Okada, Noritaka; Oshima, Hideki; Narita, Yuji; Abe, Tomonobu; Araki, Yoshimori; Mutsuga, Masato; Fujimoto, Kazuro L; Tokuda, Yoshiyuki; Usui, Akihiko

    2015-06-01

    Thoracic aortic operations still remain associated with substantial risks of death and neurologic injury. This study investigated the impact of surgical stroke on the early and late outcomes, focusing on the physical status and quality of life (QOL). From 1986 to 2008, 500 patients (aged 63 ± 13 years) underwent open thoracic aortic repair for root and ascending (31%), arch (39%), extended arch (10%), and descending and thoracoabdominal (19%) aneurysms. Brain protection consisted of retrograde cerebral perfusion (52%), antegrade cerebral perfusion (29%), and simple deep hypothermic circulatory arrest (19%). Surgical stroke was defined as a neurologic deficit persisting more than 72 hours after the operation. QOL was assessed with the Short-Form 36 Health Survey Questionnaire 5.9 ± 4.2 years after the operation. Stroke occurred in 10.3% of patients. Hospital mortality was 21% in the stroke group and 2.7% in the nonstroke group (p mental component was similar in both groups (14% vs 14%). Surgical stroke is associated with high hospital mortality and PNDs that decrease late survival and the physical component score of the QOL survey. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Application of thoracic endovascular aortic repair (TEVAR) in treating dwarfism with Stanford B aortic dissection

    Science.gov (United States)

    Qiu, Jian; Cai, Wenwu; Shu, Chang; Li, Ming; Xiong, Qinggen; Li, Quanming; Li, Xin

    2018-01-01

    Abstract Rationale: To apply thoracic endovascular aortic repair (TEVAR) to treat dwarfism complicated with Stanford B aortic dissection. Patient concerns: In this report, we presented a 63-year-old male patient of dwarfism complicated with Stanford B aortic dissection successfully treated with TEVAR. Diagnoses: He was diagnosed with dwarfism complicated with Stanford B aortic dissection. Interventions: After conservative treatment, the male patient underwent TEVAR at 1 week after hospitalization. After operation, he presented with numbness and weakness of his bilateral lower extremities, and these symptoms were significantly mitigated after effective treatment. At 1- and 3-week after TEVAR, the aorta status was maintained stable and restored. Outcomes: The patient obtained favorable clinical prognosis and was smoothly discharged. During subsequent follow-up, he remained physically stable. Lessons: TEVAR is probably an option for treating dwarfism complicated with Stanford B aortic dissection, which remains to be validated by subsequent studies with larger sample size. PMID:29703033

  13. Reverse extra-anatomic aortic arch debranching procedure allowing thoracic endovascular aortic repair of a chronic ascending aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Ludovic Canaud, MD, PhD

    2018-06-01

    Full Text Available A 79-year-old woman was admitted with a large chronic dissecting ascending aortic aneurysm starting 5 mm distal to the ostia of the left coronary artery and ending immediately proximal to the innominate artery. A reverse extra-anatomic aortic arch debranching procedure was performed. During the same operative time, through a transapical approach, a thoracic stent graft was deployed with the proximal landing zone just distal to the coronary ostia and the distal landing zone excluding the origin of the left common carotid artery. The postoperative course was uneventful. Computed tomography at 12 months documented patent extra-anatomic aortic arch debranching and no evidence of endoleak. Keywords: Ascending aorta, Thoracic aorta, Aortic dissection, Stent graft

  14. Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

    International Nuclear Information System (INIS)

    Chen, I-Ming; Chen, Po-Lin; Huang, Chun-Yang; Weng, Shih-Hsien; Chen, Wei-Yuan; Shih, Chun-Che

    2017-01-01

    PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

  15. Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection

    Energy Technology Data Exchange (ETDEWEB)

    Chen, I-Ming [National Yang Ming University, Institute of Clinical Medicine, School of Medicine (China); Chen, Po-Lin; Huang, Chun-Yang [National Yang Ming University, Department of Medicine, School of Medicine (China); Weng, Shih-Hsien; Chen, Wei-Yuan; Shih, Chun-Che, E-mail: ccshih@vghtpe.gov.tw [National Yang Ming University, Institute of Clinical Medicine, School of Medicine (China)

    2017-05-15

    PurposeThe purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection.Materials and MethodsThe patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen.ResultsA total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively.ConclusionsIncreased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection.Level of EvidenceIII.

  16. Extra-Thoracic Supra-aortic Bypass Surgery Is Safe in Thoracic Endovascular Aortic Repair and Arterial Occlusive Disease Treatment.

    Science.gov (United States)

    Gombert, Alexander; van Issum, Lea; Barbati, Mohammad E; Grommes, Jochen; Keszei, Andras; Kotelis, Drosos; Jalaie, Houman; Greiner, Andreas; Jacobs, Michael J; Kalder, Johannes

    2018-04-20

    The safety and feasibility of supra-aortic debranching as part of endovascular aortic surgery or as a treatment option for arterial occlusive disease (AOD) remains controversial. The aim of this study was to assess the clinical outcome of this surgery. This single centre, retrospective study included 107 patients (mean age 69.2 years, 38.4% women) who underwent supra-aortic bypass surgery (carotid-subclavian bypass, carotid-carotid bypass, and carotid-carotid-subclavian bypass) because of thoracic or thoraco-abdominal endovascular aortic repair (57%; 61/107) or as AOD treatment (42.9%; 46/107) between January 2006 and January 2015. Mortality, morbidity with a focus on neurological complications, and patency rate were assessed. Twenty-six of 107 (14.2%) of the debranching patients were treated under emergency conditions because of acute type B dissection or symptomatic aneurysm. Follow up, conducted by imaging interpretation and telephone interviews, continued till March 2017 (mean 42.1, 0-125, months). The in hospital mortality rate was 10.2% (11/107), all of these cases from the debranching group and related to emergency procedures (p supra-aortic bypass surgery involves low complication rates and high mid-term bypass patency rates. It is a safe and feasible treatment option in the form of debranching in combination with endovascular aortic aneurysm repair and in AOD. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  17. Neurological Complications Following Endoluminal Repair of Thoracic Aortic Disease

    International Nuclear Information System (INIS)

    Morales, J. P.; Taylor, P. R.; Bell, R. E.; Chan, Y. C.; Sabharwal, T.; Carrell, T. W. G.; Reidy, J. F.

    2007-01-01

    Open surgery for thoracic aortic disease is associated with significant morbidity and the reported rates for paraplegia and stroke are 3%-19% and 6%-11%, respectively. Spinal cord ischemia and stroke have also been reported following endoluminal repair. This study reviews the incidence of paraplegia and stroke in a series of 186 patients treated with thoracic stent grafts. From July 1997 to September 2006, 186 patients (125 men) underwent endoluminal repair of thoracic aortic pathology. Mean age was 71 years (range, 17-90 years). One hundred twenty-eight patients were treated electively and 58 patients had urgent procedures. Anesthesia was epidural in 131, general in 50, and local in 5 patients. Seven patients developed paraplegia (3.8%; two urgent and five elective). All occurred in-hospital apart from one associated with severe hypotension after a myocardial infarction at 3 weeks. Four of these recovered with cerebrospinal fluid (CSF) drainage. One patient with paraplegia died and two had permanent neurological deficit. The rate of permanent paraplegia and death was 1.6%. There were seven strokes (3.8%; four urgent and three elective). Three patients made a complete recovery, one had permanent expressive dysphasia, and three died. The rate of permanent stroke and death was 2.1%. Endoluminal treatment of thoracic aortic disease is an attractive alternative to open surgery; however, there is still a risk of paraplegia and stroke. Permanent neurological deficits and death occurred in 3.7% of the patients in this series. We conclude that prompt recognition of paraplegia and immediate insertion of a CSF drain can be an effective way of recovering spinal cord function and improving the prognosis

  18. A geometric reappraisal of proximal landing zones for thoracic endovascular aortic repair according to aortic arch types

    NARCIS (Netherlands)

    Marrocco-Trischitta, Massimiliano M.; de Beaufort, Hector W.; Secchi, Francesco; van Bakel, Theodorus M.; Ranucci, Marco; van Herwaarden, Joost A.; Moll, Frans L.; Trimarchi, Santi

    Objective: This study assessed whether the additional use of the aortic arch classification in type I, II, and III may complement Ishimaru's aortic arch map and provide valuable information on the geometry and suitability of proximal landing zones for thoracic endovascular aortic repair. Methods:

  19. Endograft Collapse After Endovascular Treatment for Thoracic Aortic Disease

    International Nuclear Information System (INIS)

    Bandorski, Dirk; Brueck, Martin; Guenther, Hans-Ulrich; Manke, Christoph

    2010-01-01

    Endovascular treatment is an established therapy for thoracic aortic disease. Collapse of the endograft is a potentially fatal complication. We reviewed 16 patients with a thoracic endograft between 2001 and 2006. Medical records of the treated patients were studied. Data collected include age, gender, diagnosis, indication for endoluminal treatment, type of endograft, and time of follow up. All patients (n = 16; mean age, 61 years; range, 21-82 years) underwent computed tomography (CT) for location of the lesion and planning of the intervention. Time of follow-up with CT scan ranged from 1 to 61 months. Indications for endovascular treatment were degenerative aneurysm (n = 7; 44%), aortic dissection (n = 2; 12%), perforated aortic ulcer (n = 4; 25%), and traumatic aortic injury (n = 3; 19%). Three patients suffered from a collapse of the endograft (one patient distal, two patients proximal) between 3 and 8 days after endovascular treatment. These patients were younger (mean age, 37 ± 25 years vs. 67 ± 16 years; P 0.05]; distal, 45 ± 23.5% vs. 38 ± 21.7% [P > 0.05]). Proximal collapse was corrected by placing a bare stent. In conclusion, risk factors for stent-graft collapse are a small lumen of the aorta and a small radius of the aortic arch curvature (young patients), as well as oversizing, which is an important risk factor and is described for different types of endografts and protheses (Gore TAG and Cook Zenith). Dilatation of the collapsed stent-graft is not sufficient. Following therapy implantation of a second stent or surgery is necessary in patients with a proximal endograft collapse. Distal endograft collapse can possibly be treated conservatively under close follow-up.

  20. An Experimental Study to Replace the Thoracic Descending Aorta for Pigs with a Self-Made Sutureless Blood Vessel

    Directory of Open Access Journals (Sweden)

    Fenglin Song

    2014-01-01

    Full Text Available To simplify the procedure of blood vessel replacement operation and shorten the vascular anastomosis time, we developed a special artificial blood vessel which can be connected to native blood vessels without suture. The self-made sutureless blood vessel (SMSBV was made from two titanium connectors and a Gore-Tex graft. To investigate blood compatibility and histocompatibility of the SMSBV, we carried thoracic descending aorta replacement using either SMSBV or Gore-Tex, respectively, in pigs. The aortic clamp time and the operative blood loss in the experimental group (using SMSBV were less than those in the control group (using Gore-Tex. The whole blood hematocrit, platelet count, plasma soluble P-selectin, plasma free hemoglobin, and interleukins 2, 6 at each time point were not different significantly between the two groups. Light microscopy and transmission electron microscopy examination showed there were layers of vascular smooth muscle cells and endothelial cells adhered in the inner wall of artificial blood vessel without any signs of thrombosis. Based on the result, we have drawn the conclusion that the application of SMSBV can significantly shorten the vascular anastomosis time, reduce operative blood loss, and show good blood and tissue compatibility.

  1. Increased interleukin-11 levels in thoracic aorta and plasma from patients with acute thoracic aortic dissection.

    Science.gov (United States)

    Xu, Yao; Ye, Jing; Wang, Menglong; Wang, Yuan; Ji, Qingwei; Huang, Ying; Zeng, Tao; Wang, Zhen; Ye, Di; Jiang, Huimin; Liu, Jianfang; Lin, Yingzhong; Wan, Jun

    2018-06-01

    Interleukin (IL) 11 is closely related to tumor and hematological system diseases. Recent studies have demonstrated that IL-11 also participates in cardiovascular diseases, including ischemia-reperfusion mediated heart injury and acute myocardial infarction. This study aimed to investigate whether IL-11 is involved in acute thoracic aortic dissection (TAD). Aortic tissue samples from normal donors and acute TAD patients were collected, and the expression of IL-11 in all aortic tissue was analyzed. In addition, blood samples from patients with chest pain were collected and divided into a non-AD (NAD) group and a TAD group according to the results of computed tomography angiography of the thoracic aorta. The plasma IL-11, IL-17 and interferon (IFN) γ in all blood samples were measured. Compared with aortic tissue of normal controls, IL-11 was significantly increased in aortic tissue of acute TAD patients, especially in the torn section. The IL-11 was derived from aorta macrophages in TAD. In addition, the plasma IL-11, IL-17 and IFN-γ were significantly higher in acute TAD patients than in NAD patients, and the correlation analysis showed that IL-11 levels were positively correlated with levels of IFN-γ, IL-17, glucose, systolic blood pressure, diastolic blood pressure, white blood cells, C-reactive proteins and D-dimers. Binary logistic regression analyses showed that elevated IL11 in patients who may have diagnostic value of TAD, but less that D-dimer. IL-11 was increased in thoracic aorta and plasma of TAD patients and may be a promising biomarker for diagnosis in patients with TAD. Copyright © 2018. Published by Elsevier B.V.

  2. Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Krishnam, Mayil S. [University of California, Cardiovascular and Thoracic Imaging, UCI Medical Center, Irvine, CA (United States); Tomasian, Anderanik; Malik, Sachin; Ruehm, Stefan G. [University of California at Los Angeles, Department of Radiological Sciences, Ronald Reagan Medical Center, Los Angeles, CA (United States); Desphande, Vibhas; Laub, Gerhard [Siemens Medical Solutions, Los Angeles, CA (United States)

    2010-06-15

    The purpose of this study was to determine the image quality and diagnostic accuracy of three-dimensional (3D) unenhanced steady state free precession (SSFP) magnetic resonance angiography (MRA) for the evaluation of thoracic aortic diseases. Fifty consecutive patients with known or suspected thoracic aortic disease underwent free-breathing ECG-gated unenhanced SSFP MRA with non-selective radiofrequency excitation and contrast-enhanced (CE) MRA of the thorax at 1.5 T. Two readers independently evaluated the two datasets for image quality in the aortic root, ascending aorta, aortic arch, descending aorta, and origins of supra-aortic arteries, and for abnormal findings. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined for both datasets. Sensitivity, specificity, and diagnostic accuracy of unenhanced SSFP MRA for the diagnosis of aortic abnormalities were determined. Abnormal aortic findings, including aneurysm (n = 47), coarctation (n = 14), dissection (n = 12), aortic graft (n = 6), intramural hematoma (n = 11), mural thrombus in the aortic arch (n = 1), and penetrating aortic ulcer (n = 9), were confidently detected on both datasets. Sensitivity, specificity, and diagnostic accuracy of SSFP MRA for the detection of aortic disease were 100% with CE-MRA serving as a reference standard. Image quality of the aortic root was significantly higher on SSFP MRA (P < 0.001) with no significant difference for other aortic segments (P > 0.05). SNR and CNR values were higher for all segments on SSFP MRA (P < 0.01). Our results suggest that free-breathing navigator-gated 3D SSFP MRA with non-selective radiofrequency excitation is a promising technique that provides high image quality and diagnostic accuracy for the assessment of thoracic aortic disease without the need for intravenous contrast material. (orig.)

  3. Assessment of thoracic aortic elasticity: a preliminary study using electrocardiographically gated dual-source CT

    International Nuclear Information System (INIS)

    Li, Ning; Guo, Lijun; Sun, Haitao; Gao, Fei; Liu, Cheng; Beck, Thomas; Chen, Jiuhong; Biermann, Christina

    2011-01-01

    To gain a new insight into the elastic properties of the thoracic aorta in patients without aortic diseases using electrocardiographically (ECG)-gated dual-source (DS) CT. 56 subjects with no cardiovascular disease, selected from 2,700 people undergoing ECG-gated DSCT examination, were divided into three groups according to their age. CT data were reconstructed in 5% step throughout the RR interval. Diameter and area were measured at the curve of the ascending aorta (AA) and at the same level of the descending aorta (DA). The pulsation and elasticity of the aorta were evaluated. Aortic diameter changes were noted throughout the cardiac cycle. The maximum average diameter was seen at an RR interval of 24.02 ± 4.99% for the AA and 25.63 ± 4.77% for the DA. The minimum was at 93.5 ± 4.04% for the AA and 96.6 ± 4.58% for the DA. There was an age-dependent decrease in elasticity, while different correlation coefficients were found between various age groups and different elastic parameters. The properties of aortic pulsation and wall elasticity could be well shown by ECG-gated DSCT. The new findings regarding segment difference and age relevance were significant and should be taken into account in clinical trials and treatments for the elasticity related cardiovascular diseases. (orig.)

  4. Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases

    International Nuclear Information System (INIS)

    Krishnam, Mayil S.; Tomasian, Anderanik; Malik, Sachin; Ruehm, Stefan G.; Desphande, Vibhas; Laub, Gerhard

    2010-01-01

    The purpose of this study was to determine the image quality and diagnostic accuracy of three-dimensional (3D) unenhanced steady state free precession (SSFP) magnetic resonance angiography (MRA) for the evaluation of thoracic aortic diseases. Fifty consecutive patients with known or suspected thoracic aortic disease underwent free-breathing ECG-gated unenhanced SSFP MRA with non-selective radiofrequency excitation and contrast-enhanced (CE) MRA of the thorax at 1.5 T. Two readers independently evaluated the two datasets for image quality in the aortic root, ascending aorta, aortic arch, descending aorta, and origins of supra-aortic arteries, and for abnormal findings. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined for both datasets. Sensitivity, specificity, and diagnostic accuracy of unenhanced SSFP MRA for the diagnosis of aortic abnormalities were determined. Abnormal aortic findings, including aneurysm (n = 47), coarctation (n = 14), dissection (n = 12), aortic graft (n = 6), intramural hematoma (n = 11), mural thrombus in the aortic arch (n = 1), and penetrating aortic ulcer (n = 9), were confidently detected on both datasets. Sensitivity, specificity, and diagnostic accuracy of SSFP MRA for the detection of aortic disease were 100% with CE-MRA serving as a reference standard. Image quality of the aortic root was significantly higher on SSFP MRA (P 0.05). SNR and CNR values were higher for all segments on SSFP MRA (P < 0.01). Our results suggest that free-breathing navigator-gated 3D SSFP MRA with non-selective radiofrequency excitation is a promising technique that provides high image quality and diagnostic accuracy for the assessment of thoracic aortic disease without the need for intravenous contrast material. (orig.)

  5. Overexpression of interleukin-1β and interferon-γ in type I thoracic aortic dissections and ascending thoracic aortic aneurysms: possible correlation with matrix metalloproteinase-9 expression and apoptosis of aortic media cells.

    Science.gov (United States)

    Zhang, Lei; Liao, Ming-fang; Tian, Lei; Zou, Si-li; Lu, Qing-sheng; Bao, Jun-min; Pei, Yi-fei; Jing, Zai-ping

    2011-07-01

    To examine the expression of interleukin-1β and interferon-γ and their possible roles in aortic dissections and aneurysms. Aortic specimens were obtained from patients with type I thoracic aortic dissection, ascending thoracic aortic aneurysms, and control organ donors. The expression of interleukin-1β, interferon-γ, matrix metalloproteinase-9, and signal transduction factors phospho-p38 and phosphorylated c-jun N-terminal kinase (phospho-JNK) were detected by real time reverse transcription-polymerase chain reaction (real time RT-PCR), Western blot, and immunohistochemistry, respectively. Terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL) staining was performed to detect apoptosis of media cells. The correlation of these factors and apoptosis was also studied. Apoptosis in the media of thoracic aortic dissection and in ascending thoracic aortic aneurysms was dramatically higher than in the control group. The expression of interleukin-1β gradually increased from the control group, thoracic aortic dissection to ascending thoracic aortic aneurysms (p matrix metalloproteinase-9 was significantly increased in the media of thoracic aortic dissection and ascending thoracic aortic aneurysms compared with the control group (p correlations between interleukin-1β versus matrix metalloproteinase-9, interleukin-1β versus phospho-p38 in thoracic aortic dissection (p matrix metalloproteinase-9, interferon-γ versus phospho-JNK, interferon-γ versus apoptosis, and interleukin-1β versus apoptosis in ascending thoracic aortic aneurysms (p = 0.02, 0.02, p matrix metalloproteinase-9 and the apoptosis of media cells in humans. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  6. Thoracic aortic aneurysm in a child due to cystic medial necrosis

    International Nuclear Information System (INIS)

    Kuribayashi, Sachio; Watabe, Tsuneya; Ohtaki, Makoto; Matsuyama, Shoya; Ogawa, Junichi

    1983-01-01

    The valuable role of computed tomography (CT) was stressed in the diagnosis of thoracic aortic aneurysm in an asymptomatic 12-year-old child. She initially presented mediastinal mass on plain chest film. A saccular thoracic aortic aneurysm was highly suspected from the CT findings, and it was confirmed on angiography. Pathological examination of the aneurysmal wall revealed cystic medial necrosis. (author)

  7. Thoracic aorta 3D hemodynamics in pediatric and young adult patients with bicuspid aortic valve.

    Science.gov (United States)

    Allen, Bradley D; van Ooij, Pim; Barker, Alex J; Carr, Maria; Gabbour, Maya; Schnell, Susanne; Jarvis, Kelly B; Carr, James C; Markl, Michael; Rigsby, Cynthia; Robinson, Joshua D

    2015-10-01

    To evaluate the 3D hemodynamics in the thoracic aorta of pediatric and young adult bicuspid aortic valve (BAV) patients. 4D flow MRI was performed in 30 pediatric and young adult BAV patients (age: 13.9 ± 4.4 (range: [3.4, 20.7]) years old, M:F = 17:13) as part of this Institutional Review Board-approved study. Nomogram-based aortic root Z-scores were calculated to assess aortic dilatation and degree of aortic stenosis (AS) severity was assessed on MRI. Data analysis included calculation of time-averaged systolic 3D wall shear stress (WSSsys ) along the entire aorta wall, and regional quantification of maximum and mean WSSsys and peak systolic velocity (velsys ) in the ascending aorta (AAo), arch, and descending aorta (DAo). The 4D flow MRI AAo velsys was also compared with echocardiography peak velocity measurements. There was a positive correlation with both mean and max AAo WSSsys and peak AAo velsys (mean: r = 0.84, P max: r = 0.94, P max: rS  = 0.70, P < 0.001). AAo peak velocity was significantly higher when measured with echo compared with 4D flow MRI (2.1 ± 0.98 m/s versus 1.27 ± 0.49 m/s, P < 0.001). In pediatric and young adult patients with BAV, AS and peak ascending aorta velocity are associated with increased AAo WSS, while aortic dilation, age, and body surface area do not significantly impact AAo hemodynamics. Prospective studies are required to establish the role of WSS as a risk-stratification tool in these patients. © 2015 Wiley Periodicals, Inc.

  8. Retrograde ascending aortic dissection during or after thoracic aortic stent graft placement: insight from the European registry on endovascular aortic repair complications

    DEFF Research Database (Denmark)

    Eggebrecht, Holger; Thompson, Matt; Rousseau, Hervé

    2009-01-01

    BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic...

  9. Intensive Care Management of Thoracic Aortic Surgical Patients, Including Thoracic and Infradiaphragmatic Endovascular Repair (EVAR/TEVAR).

    Science.gov (United States)

    Cole, Sheela Pai

    2015-12-01

    The patient with thoracic aortic disease can present for open or endovascular repair. Thoracic endovascular aortic repair (TEVAR) has emerged as a minimally invasive option for a multitude of aortic pathology, including dissections, aneurysms, traumatic injuries, and ulcers. Postoperative management of these patients depends on the extent of procedure, whether it was open or endovascular, and, finally, on the preoperative comorbidities present. While procedural success has catapulted TEVAR to popularity, midterm results have been mixed. Additionally, periprocedural complications such as paraplegia and renal failure remain a significant morbidity in these patients. © The Author(s) 2015.

  10. Inflammatory Cell Infiltrates in Acute and Chronic Thoracic Aortic Dissection.

    Science.gov (United States)

    Wu, Darrell; Choi, Justin C; Sameri, Aryan; Minard, Charles G; Coselli, Joseph S; Shen, Ying H; LeMaire, Scott A

    2013-12-01

    Thoracic aortic dissection (TAD) is a highly lethal cardiovascular disease. Injury to the intima and media allows pulsatile blood to enter the media, leading to dissection formation. Inflammatory cells then infiltrate the site of aortic injury to clear dead cells and damaged tissue. This excessive inflammation may play a role in aneurysm formation after dissection. Using immunohistochemistry, we compared aortic tissues from patients with acute TAD (n = 11), patients with chronic TAD (n = 35), and donor controls (n = 20) for the presence of CD68+ macrophages, neutrophils, mast cells, and CD3+ T lymphocytes. Tissue samples from patients with acute or chronic TAD generally had significantly more inflammatory cells in both the medial and adventitial layers than did the control samples. In tissues from patients with acute TAD, the adventitia had more of the inflammatory cells studied than did the media. The pattern of increase in inflammatory cells was similar in chronic and acute TAD tissues, except for macrophages, which were seen more frequently in the adventitial layer of acute TAD tissue than in the adventitia of chronic TAD tissue. The inflammatory cell content of both acute and chronic TAD tissue was significantly different from that of control tissue. However, the inflammatory cell profile of aneurysmal chronic TAD was similar to that of acute TAD. This may reflect a sustained injury response that contributes to medial degeneration and aneurysm formation.

  11. Long descending cervical propriospinal neurons differ from thoracic propriospinal neurons in response to low thoracic spinal injury

    Directory of Open Access Journals (Sweden)

    Stelzner Dennis J

    2010-11-01

    Full Text Available Abstract Background Propriospinal neurons, with axonal projections intrinsic to the spinal cord, have shown a greater regenerative response than supraspinal neurons after axotomy due to spinal cord injury (SCI. Our previous work focused on the response of axotomized short thoracic propriospinal (TPS neurons following a low thoracic SCI (T9 spinal transection or moderate spinal contusion injury in the rat. The present investigation analyzes the intrinsic response of cervical propriospinal neurons having long descending axons which project into the lumbosacral enlargement, long descending propriospinal tract (LDPT axons. These neurons also were axotomized by T9 spinal injury in the same animals used in our previous study. Results Utilizing laser microdissection (LMD, qRT-PCR, and immunohistochemistry, we studied LDPT neurons (located in the C5-C6 spinal segments between 3-days, and 1-month following a low thoracic (T9 spinal cord injury. We examined the response of 89 genes related to growth factors, cell surface receptors, apoptosis, axonal regeneration, and neuroprotection/cell survival. We found a strong and significant down-regulation of ~25% of the genes analyzed early after injury (3-days post-injury with a sustained down-regulation in most instances. In the few genes that were up-regulated (Actb, Atf3, Frs2, Hspb1, Nrap, Stat1 post-axotomy, the expression for all but one was down-regulated by 2-weeks post-injury. We also compared the uninjured TPS control neurons to the uninjured LDPT neurons used in this experiment for phenotypic differences between these two subpopulations of propriospinal neurons. We found significant differences in expression in 37 of the 84 genes examined between these two subpopulations of propriospinal neurons with LDPT neurons exhibiting a significantly higher base line expression for all but 3 of these genes compared to TPS neurons. Conclusions Taken collectively these data indicate a broad overall down

  12. Thoracic aortic aneurysm in a buck associated with caseous lymphadenitis

    Directory of Open Access Journals (Sweden)

    R.R. Pinheiro

    2013-06-01

    Full Text Available This paper reports the clinical, bacteriological and pathological findings of a thoracic aortic aneurysm in a four-year-old Anglo-Nubian goat buck, related to a framework of visceral caseous lymphadenitis. General clinical examination showed heart rate of 75 beats per minute, respiratory rate of 20 movements per minute and ruminal movements of four movements per minute. Superficial lymph nodes were normal upon palpation. Rectal temperature was slightly high (40.5°C. Blood test showed an intense leukocytosis (54,000/µL, characterized by strong neutrophil shift to the left. At necropsy, a large blood clot was detected in the thoracic cavity. The thickening of the myocardium and dilatation of the aorta in the thoracic portion, presenting a saculiform format was also observed. A large number of abscesses were disseminated in the media and intima layers of aorta. The aorta lumen obstruction by arterial plaques consisting of inflammatory infiltrate, predominantly neutrophilic was also detected. Abscesses were found spread in turbinate, rumen, reticulum, kidneys, liver, spleen, testicles and aorta wall. The microbiological exam of exudate confirmed Corynebacterium pseudotuberculosis as the causal agent.

  13. Heartbeat-related displacement of the thoracic aorta in patients with chronic aortic dissection type B: Quantification by dynamic CTA

    Energy Technology Data Exchange (ETDEWEB)

    Weber, Tim F. [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany)], E-mail: tim.weber@med.uni-heidelberg.de; Ganten, Maria-Katharina [German Cancer Research Center, Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany)], E-mail: m.ganten@dkfz.de; Boeckler, Dittmar [University of Heidelberg, Department of Vascular and Endovascular Surgery, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany)], E-mail: dittmar.boeckler@med.uni-heidelberg.de; Geisbuesch, Philipp [University of Heidelberg, Department of Vascular and Endovascular Surgery, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany)], E-mail: philipp.geisbuesch@med.uni-heidelberg.de; Kauczor, Hans-Ulrich [University of Heidelberg, Department of Diagnostic and Interventional Radiology, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany)], E-mail: hu.kauczor@med.uni-heidelberg.de; Tengg-Kobligk, Hendrik von [German Cancer Research Center, Department of Radiology, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany)], E-mail: h.vontengg@dkfz.de

    2009-12-15

    Purpose: The purpose of this study was to characterize the heartbeat-related displacement of the thoracic aorta in patients with chronic aortic dissection type B (CADB). Materials and methods: Electrocardiogram-gated computed tomography angiography was performed during inspiratory breath-hold in 11 patients with CADB: Collimation 16 mm x 1 mm, pitch 0.2, slice thickness 1 mm, reconstruction increment 0.8 mm. Multiplanar reformations were taken for 20 equidistant time instances through both ascending (AAo) and descending aorta (true lumen, DAoT; false lumen, DAoF) and the vertex of the aortic arch (VA). In-plane vessel displacement was determined by region of interest analysis. Results: Mean displacement was 5.2 {+-} 1.7 mm (AAo), 1.6 {+-} 1.0 mm (VA), 0.9 {+-} 0.4 mm (DAoT), and 1.1 {+-} 0.4 mm (DAoF). This indicated a significant reduction of displacement from AAo to VA and DAoT (p < 0.05). The direction of displacement was anterior for AAo and cranial for VA. Conclusion: In CADB, the thoracic aorta undergoes a heartbeat-related displacement that exhibits an unbalanced distribution of magnitude and direction along the thoracic vessel course. Since consecutive traction forces on the aortic wall have to be assumed, these observations may have implications on pathogenesis of and treatment strategies for CADB.

  14. Endovascular Treatment of Late Thoracic Aortic Aneurysms after Surgical Repair of Congenital Aortic Coarctation in Childhood

    Science.gov (United States)

    Juszkat, Robert; Perek, Bartlomiej; Zabicki, Bartosz; Trojnarska, Olga; Jemielity, Marek; Staniszewski, Ryszard; Smoczyk, Wiesław; Pukacki, Fryderyk

    2013-01-01

    Background In some patients, local surgery-related complications are diagnosed many years after surgery for aortic coarctation. The purposes of this study were: (1) to systematically evaluate asymptomatic adults after Dacron patch repair in childhood, (2) to estimate the formation rate of secondary thoracic aortic aneurysms (TAAs) and (3) to assess outcomes after intravascular treatment for TAAs. Methods This study involved 37 asymptomatic patients (26 female and 11 male) who underwent surgical repair of aortic coarctation in the childhood. After they had reached adolescence, patients with secondary TAAs were referred to endovascular repair. Results Follow-up studies revealed TAA in seven cases (19%) (including six with the gothic type of the aortic arch) and mild recoarctation in other six (16%). Six of the TAA patients were treated with stentgrafts, but one refused to undergo an endovascular procedure. In three cases, stengrafts covered the left subclavian artery (LSA), in another the graft was implanted distally to the LSA. In two individuals, elective hybrid procedures were performed with surgical bypass to the supraaortic arteries followed by stengraft implantation. All subjects survived the secondary procedures. One patient developed type Ia endoleak after stentgraft implantation that was eventually treated with a debranching procedure. Conclusions The long-term course of clinically asymptomatic patients after coarctation patch repair is not uncommonly complicated by formation of TAAs (particularly in individuals with the gothic pattern of the aortic arch) that can be treated effectively with stentgrafts. However, in some patients hybrid procedures may be necessary. PMID:24386233

  15. Long-term results after proximal thoracic aortic redo surgery.

    Directory of Open Access Journals (Sweden)

    Martin Czerny

    Full Text Available OBJECTIVE: To evaluate early and mid-term results in patients undergoing proximal thoracic aortic redo surgery. METHODS: We analyzed 60 patients (median age 60 years, median logistic EuroSCORE 40 who underwent proximal thoracic aortic redo surgery between January 2005 and April 2012. Outcome and risk factors were analyzed. RESULTS: In hospital mortality was 13%, perioperative neurologic injury was 7%. Fifty percent of patients underwent redo surgery in an urgent or emergency setting. In 65%, partial or total arch replacement with or without conventional or frozen elephant trunk extension was performed. The preoperative logistic EuroSCORE I confirmed to be a reliable predictor of adverse outcome- (ROC 0.786, 95%CI 0.64-0.93 as did the new EuroSCORE II model: ROC 0.882 95%CI 0.78-0.98. Extensive individual logistic EuroSCORE I levels more than 67 showed an OR of 7.01, 95%CI 1.43-34.27. A EuroSCORE II larger than 28 showed an OR of 4.44 (95%CI 1.4-14.06. Multivariate logistic regression analysis identified a critical preoperative state (OR 7.96, 95%CI 1.51-38.79 but not advanced age (OR 2.46, 95%CI 0.48-12.66 as the strongest independent predictor of in-hospital mortality. Median follow-up was 23 months (1-52 months. One year and five year actuarial survival rates were 83% and 69% respectively. Freedom from reoperation during follow-up was 100%. CONCLUSIONS: Despite a substantial early attrition rate in patients presenting with a critical preoperative state, proximal thoracic aortic redo surgery provides excellent early and mid-term results. Higher EuroSCORE I and II levels and a critical preoperative state but not advanced age are independent predictors of in-hospital mortality. As a consequence, age alone should no longer be regarded as a contraindication for surgical treatment in this particular group of patients.

  16. Morphological risk factors of stroke during thoracic endovascular aortic repair.

    Science.gov (United States)

    Kotelis, Drosos; Bischoff, Moritz S; Jobst, Bertram; von Tengg-Kobligk, Hendrik; Hinz, Ulf; Geisbüsch, Philipp; Böckler, Dittmar

    2012-12-01

    This study aims to identify independent factors correlating to an increased risk of perioperative stroke during thoracic endovascular aortic repair (TEVAR). A prospective maintained TEVAR database, medical records, and imaging studies of 300 patients (205 men; median age of all, 66 years, range 21-89), who underwent TEVAR between March 1997 and February 2011, were reviewed. Preoperative CT data sets were reviewed by two experienced radiologists with focus on the atheroma burden in the aortic arch (grade I, normal, to grade V, ulcerated or pedunculated atheroma). Aortic arch geometry (arch types I-III) was documented. Further parameters included in the univariate analysis were age, gender, urgency of repair, duration of procedure, adenosine-induced cardiac arrest or rapid pacing, proximal landing zone, left subclavian artery (LSA) coverage, and number of stent grafts. Multivariate logistic regression analysis was performed to assess the independent correlations of potential risk factors. Atherosclerotic aneurysm was the most common pathology (44%). One hundred and fifty-four of our patients (51%) were treated under urgent or emergent conditions. Seventeen percent of all patients had significant arch atheroma (grade IV or V), and 43% had a steep type III aortic arch. The perioperative stroke was 4% (12 patients; median age, 73 years, range 31-78). Two strokes were lethal (0.7%). All strokes were classified as embolic based on imaging characteristics. In eight patients, strokes were located in the left cerebral hemisphere (seven of them in the anterior and one in the posterior circulation). Four stroke patients (one in the left posterior circulation) underwent LSA coverage without revascularization. Three stroke patients had severe arch atheroma grade V. Five patients suffering stroke were recognized to have a type III aortic arch. Strokes were equally distributed between zones 0-2 vs. 3-4 (n = 6 each, 5 vs. 3.3%). The highest incidence was found in zone 1 (11

  17. Relation of thoracic aortic and aortic valve calcium to coronary artery calcium and risk assessment.

    Science.gov (United States)

    Wong, Nathan D; Sciammarella, Maria; Arad, Yadon; Miranda-Peats, Romalisa; Polk, Donna; Hachamovich, Rory; Friedman, John; Hayes, Sean; Daniell, Anthony; Berman, Daniel S

    2003-10-15

    Aortic calcium, aortic valve calcium (AVC), and coronary artery calcium (CAC) have been associated with cardiovascular event risk. We examined the prevalence of thoracic aortic calcium (TAC) and AVC in relation to the presence and extent of CAC, cardiovascular risk factors, and estimated risk of coronary heart disease (CHD). In 2,740 persons without known CHD aged 20 to 79 years, CAC was assessed by electron beam- or multidetector-computed tomography. We determined the prevalence of TAC and AVC in relation to CAC, CHD risk factors, and predicted 10-year risk of CHD. A close correspondence of TAC and AVC was observed with CAC. TAC and AVC increased with age; by the eighth decade of life, the prevalence of TAC was similar to that of CAC (>80%), and 36% of men and 24% of women had AVC. Age, male gender, and low-density lipoprotein cholesterol were directly related to the likelihood of CAC, TAC, and AVC; higher diastolic blood pressure and cigarette smoking additionally predicted CAC. Body mass index and higher systolic and lower diastolic blood pressures were also related to TAC, and higher body mass index and lower diastolic blood pressure were related to AVC. Calculated risk of CHD increased with the presence of AVC and TAC across levels of CAC. TAC and AVC provided incremental value over CAC in association with the 10-year calculated risk of CHD. If longitudinal studies show an incremental value of aortic and aortic valve calcium over that of CAC for prediction of cardiovascular events, future guidelines for risk assessment incorporating CAC assessment may additionally incorporate the measurement of aortic and/or aortic valve calcium.

  18. Three-dimensional thoracic aorta principal strain analysis from routine ECG-gated computerized tomography: feasibility in patients undergoing transcatheter aortic valve replacement.

    Science.gov (United States)

    Satriano, Alessandro; Guenther, Zachary; White, James A; Merchant, Naeem; Di Martino, Elena S; Al-Qoofi, Faisal; Lydell, Carmen P; Fine, Nowell M

    2018-05-02

    Functional impairment of the aorta is a recognized complication of aortic and aortic valve disease. Aortic strain measurement provides effective quantification of mechanical aortic function, and 3-dimenional (3D) approaches may be desirable for serial evaluation. Computerized tomographic angiography (CTA) is routinely performed for various clinical indications, and offers the unique potential to study 3D aortic deformation. We sought to investigate the feasibility of performing 3D aortic strain analysis in a candidate population of patients undergoing transcatheter aortic valve replacement (TAVR). Twenty-one patients with severe aortic valve stenosis (AS) referred for TAVR underwent ECG-gated CTA and echocardiography. CTA images were analyzed using a 3D feature-tracking based technique to construct a dynamic aortic mesh model to perform peak principal strain amplitude (PPSA) analysis. Segmental strain values were correlated against clinical, hemodynamic and echocardiographic variables. Reproducibility analysis was performed. The mean patient age was 81±6 years. Mean left ventricular ejection fraction was 52±14%, aortic valve area (AVA) 0.6±0.3 cm 2 and mean AS pressure gradient (MG) 44±11 mmHg. CTA-based 3D PPSA analysis was feasible in all subjects. Mean PPSA values for the global thoracic aorta, ascending aorta, aortic arch and descending aorta segments were 6.5±3.0, 10.2±6.0, 6.1±2.9 and 3.3±1.7%, respectively. 3D PSSA values demonstrated significantly more impairment with measures of worsening AS severity, including AVA and MG for the global thoracic aorta and ascending segment (panalysis is clinically feasible from routine ECG-gated CTA. Appropriate reductions in PSSA were identified with increasing AS hemodynamic severity. Expanded study of 3D aortic PSSA for patients with various forms of aortic disease is warranted.

  19. Bio-chemo-mechanics of thoracic aortic aneurysms.

    Science.gov (United States)

    Wagenseil, Jessica E

    2018-03-01

    Most thoracic aortic aneurysms (TAAs) occur in the ascending aorta. This review focuses on the unique bio-chemo-mechanical environment that makes the ascending aorta susceptible to TAA. The environment includes solid mechanics, fluid mechanics, cell phenotype, and extracellular matrix composition. Advances in solid mechanics include quantification of biaxial deformation and complex failure behavior of the TAA wall. Advances in fluid mechanics include imaging and modeling of hemodynamics that may lead to TAA formation. For cell phenotype, studies demonstrate changes in cell contractility that may serve to sense mechanical changes and transduce chemical signals. Studies on matrix defects highlight the multi-factorial nature of the disease. We conclude that future work should integrate the effects of bio-chemo-mechanical factors for improved TAA treatment.

  20. Thoracic aortic aneurysm: A rare cause of elevated hemidiaphragm

    Directory of Open Access Journals (Sweden)

    Md Arshad Ejazi

    2016-01-01

    Full Text Available Phrenic nerve palsy causing hemidiaphragm paralysis is a very uncommon feature of thoracic aortic aneurysm. In one case, a 30 year male complained of chronic dull aching chest pain, and hoarseness of voice; posteroanterior view chest radiograph revealed large spherical radiopacity on the left upper lung zone with smooth lobulated margin with elevated left hemidiaphragm. On Colour Doppler sonography, lesion was anechoic on gray scale sonography but on Doppler analysis revealed intense internal vascularity within it with characteristic "Ying Yang" sign. The finding favor the vascular origin of the lesion and a diagnosis of an arterial aneurysm was made Contrast-enhanced computed tomography (CT of the thorax revealed a large well defined spherical lesion of 8 × 10 cm size with smooth well defined margin arising from the aortic arch and attenuation of impending rupture or dissection were lesion on immediate post contrast and delayed scan was similar to that of aorta. Left hemidiaphragm elevation was explained by the gross mass effect of the aneurysm causing right phrenic nerve palsy.

  1. Association between thoracic aortic disease and inguinal hernia.

    Science.gov (United States)

    Olsson, Christian; Eriksson, Per; Franco-Cereceda, Anders

    2014-08-21

    The study hypothesis was that thoracic aortic disease (TAD) is associated with a higher-than-expected prevalence of inguinal hernia. Such an association has been reported for abdominal aortic aneurysm (AAA) and hernia. Unlike AAA, TAD is not necessarily detectable with clinical examination or ultrasound, and there are no population-based screening programs for TAD. Therefore, conditions associated with TAD, such as inguinal hernia, are of particular clinical relevance. The prevalence of inguinal hernia in subjects with TAD was determined from nation-wide register data and compared to a non-TAD group (patients with isolated aortic stenosis). Groups were balanced using propensity score matching. Multivariable statistical analysis (logistic regression) was performed to identify variables independently associated with hernia. Hernia prevalence was 110 of 750 (15%) in subjects with TAD versus 29 of 301 (9.6%) in non-TAD, P=0.03. This statistically significant difference remained after propensity score matching: 21 of 159 (13%) in TAD versus 14 of 159 (8.9%) in non-TAD, PTAD, OR 1.8 (1.1 to 2.8), P=0.015. The prevalence of inguinal hernia (15%) in TAD is higher than expected in a general population and higher in TAD, compared to non-TAD. TAD is independently associated with hernia in multivariable analysis. Presence or history of hernia may be of importance in detecting TAD, and the association warrants further study. © 2014 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  2. Clinical and genetic aspects of Marfan syndrome and familial thoracic aortic aneurysms and dissections

    NARCIS (Netherlands)

    Hilhorst-Hofstee, Yvonne

    2013-01-01

    This thesis concerns the clinical and genetic aspects of familial thoracic aortic aneurysms and dissections, in particular in Marfan syndrome. It includes the Dutch multidisciplinary guidelines for diagnosis and management of Marfan syndrome. These guidelines contain practical directions for

  3. Comparative Study of Cerebral Protection during Surgery of Thoracic Aortic Aneurysm

    OpenAIRE

    Sueda, Taijiro; Nomimura, Takayuki; Kagawa, Tetsuya; Morita, Satoru; Hayashi, Saiho; Orihashi, Kazumasa; Shikata, Hiroo; Ryuu, Gou; Hamanaka, Yoshiharu; Matsuura, Yuichiro; Kawaue, Yasushi; Kanehiro, Keiichi; Ishihara, Hiroshi

    1992-01-01

    During the past 5 years, 30 cases of thoracic aortic aneurysm were treated. Selective cerebral perfusion (SCP) and retrograde cerebral perfusion (RCP) were conducted for cerebral protection during aortic cross clamping. SCP was carried out in 5 cases of dissecting aneurysm (all Stanford type A, including a case of AAE) and 3 cases of arch aneurysm. RCP was conducted in 5 cases of dissecting aneurysm (4 Stanford type A; 1 Stanford type B with retrograde dissection) and 2 cases of aortic arch a...

  4. Blunt Cardiac Injury in Trauma Patients with Thoracic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Rathachai Kaewlai

    2011-01-01

    Full Text Available Trauma patients with thoracic aortic injury (TAI suffer blunt cardiac injury (BCI at variable frequencies. This investigation aimed to determine the frequency of BCI in trauma patients with TAI and compare with those without TAI. All trauma patients with TAI who had admission electrocardiography (ECG and serum creatine kinase-MB (CK-MB from January 1999 to May 2009 were included as a study group at a level I trauma center. BCI was diagnosed if there was a positive ECG with either an elevated CK-MB or abnormal echocardiography. There were 26 patients (19 men, mean age 45.1 years, mean ISS 34.4 in the study group; 20 had evidence of BCI. Of 52 patients in the control group (38 men, mean age 46.9 years, mean ISS 38.7, eighteen had evidence of BCI. There was a significantly higher rate of BCI in trauma patients with TAI versus those without TAI (77% versus 35%, P<0.001.

  5. A Rare Entity: Traumatic Thoracic Aortic Injury in a Patient with Aberrant Right Subclavian Artery.

    Science.gov (United States)

    Patel, Hiten Mohanbhai; Banerjee, Shubhabrata; Bulsara, Shahzad; Sahu, Tapish; Sheorain, Virender K; Grover, Tarun; Parakh, Rajiv

    2017-05-01

    Aberrant right subclavian artery is an uncommon entity incidence ranging from 0.5 to 2.5%. Management of thoracic aortic injury in the presence of such anomalies can be a challenge. We present here a case of traumatic aortic injury, which was incidentally found to have an asymptomatic aberrant right subclavian artery. The patient was managed by an endovascular repair of thoracic aortic injury with an endograft and a right carotid to subclavian artery bypass as a hybrid procedure. A 40-year male patient was brought to the emergency in shock with an alleged history of road traffic accident an hour back. After initial resuscitation as per advance trauma life support protocol, imaging revealed thoracic aortic injury with aberrant right subclavian artery with multiple rib and bilateral humerus fracture. After primary stabilization of arm fractures, the patient was shifted to a hybrid operation room. As the aortic injury was within 10 mm of the origin of both subclavian arteries, it was decided to cover the origin of both subclavian arteries and land the endograft distal to the left carotid artery origin. Since there was a right dominant vertebral artery on imaging, right carotid to right subclavian artery bypass was done with expanded polytetrafluoroethylene graft to prevent posterior circulatory stroke along with thoracic endovascular aortic repair to seal the thoracic aortic injury. After endovascular repair of thoracic aortic injury, left subclavian artery perfusion was maintained through left vertebral artery; and hence, revascularization of left subclavian artery was deferred. After management of all fractures, the patient was discharged 3 weeks after the date of admission without any complications. At 6 months follow-up, patient was stable and images showed patent bypass graft and sealed aortic injury. In a trauma setting with multiple injuries, hybrid procedure with a thoracic endograft is associated with low mortality and morbidity; hence, it is the treatment

  6. Detection of thoracic aortic prosthetic graft infection with 18F-fluorodeoxyglucose positron emission tomography/computed tomography.

    Science.gov (United States)

    Tokuda, Yoshiyuki; Oshima, Hideki; Araki, Yoshimori; Narita, Yuji; Mutsuga, Masato; Kato, Katsuhiko; Usui, Akihiko

    2013-06-01

    To investigate the diagnostic value of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in detecting thoracic aortic prosthetic graft infection. Nine patients with clinically suspected thoracic aortic graft infection underwent FDG-PET/CT scanning. In these patients, the diagnoses could not be confirmed using conventional modalities. The patients' clinical courses were retrospectively reviewed. On the basis of surgical, microbiological and clinical follow-up findings, the aortic grafts were considered infected in 4 patients and not infected in 5. All 4 patients with graft infection (root: 2 cases, arch: 1 case and descending: 1 case) eventually underwent in situ re-replacement. Two of the 4 patients also had abdominal grafts; however, only the thoracic grafts were replaced because uptake was low around the abdominal grafts. The maximal standardized uptake value (SUVmax) in the perigraft area was higher in the infected group than in the non-infected group (11.4 ± 4.5 vs 6.9 ± 6.4), although the difference was not statistically significant. According to the receiver operating characteristic analysis, SUVmax >8 appeared to be the cut-off value in distinguishing the two groups (sensitivity: 1.0 and specificity: 0.8). FDG-PET/CT is useful for confirming the presence of graft infection by detecting high uptake around grafts and excluding other causes of inflammation. An SUVmax value greater than 8 around a graft suggests the presence of graft infection. In addition, FDG-PET/CT can be used to clarify the precise extent of infection. This is especially useful if multiple separated prosthetic grafts have been implanted.

  7. Application of thoracic endovascular aortic repair (TEVAR) in treating dwarfism with Stanford B aortic dissection: A case report.

    Science.gov (United States)

    Qiu, Jian; Cai, Wenwu; Shu, Chang; Li, Ming; Xiong, Qinggen; Li, Quanming; Li, Xin

    2018-04-01

    To apply thoracic endovascular aortic repair (TEVAR) to treat dwarfism complicated with Stanford B aortic dissection. In this report, we presented a 63-year-old male patient of dwarfism complicated with Stanford B aortic dissection successfully treated with TEVAR. He was diagnosed with dwarfism complicated with Stanford B aortic dissection. After conservative treatment, the male patient underwent TEVAR at 1 week after hospitalization. After operation, he presented with numbness and weakness of his bilateral lower extremities, and these symptoms were significantly mitigated after effective treatment. At 1- and 3-week after TEVAR, the aorta status was maintained stable and restored. The patient obtained favorable clinical prognosis and was smoothly discharged. During subsequent follow-up, he remained physically stable. TEVAR is probably an option for treating dwarfism complicated with Stanford B aortic dissection, which remains to be validated by subsequent studies with larger sample size.

  8. Endovascular stent graft treatment of acute thoracic aortic transections due to blunt force trauma.

    LENUS (Irish Health Repository)

    Bjurlin, Marc A

    2012-02-01

    Endovascular stent graft treatment of acute thoracic aortic transections is an encouraging minimally invasive alternative to open surgical repair. Between 2006 and 2008, 16 patients with acute thoracic aortic transections underwent evaluation at our institution. Seven patients who were treated with an endovascular stent graft were reviewed. The mean Glasgow Coma Score was 13.0, probability of survival was .89, and median injury severity score was 32. The mean number of intensive care unit days was 7.7, mean number of ventilator support days was 5.4, and hospital length of stay was 10 days. Mean blood loss was 285 mL, and operative time was 143 minutes. Overall mortality was 14%. Procedure complications were a bleeding arteriotomy site and an endoleak. Endovascular treatment of traumatic thoracic aortic transections appears to demonstrate superior results with respect to mortality, blood loss, operative time, paraplegia, and procedure-related complications when compared with open surgical repair literature.

  9. Potential Long-Term Complications of Endovascular Stent Grafting for Blunt Thoracic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Larry E. Miller

    2012-01-01

    Full Text Available Blunt thoracic aortic injury (BTAI is a rare, but lethal, consequence of rapid deceleration events. Most victims of BTAI die at the scene of the accident. Of those who arrive to the hospital alive, expedient aortic intervention significantly improves survival. Thoracic endovascular aortic repair (TEVAR has been accepted as the standard of care for BTAI at many centers, primarily due to the convincing evidence of lower mortality and morbidity in comparison to open surgery. However, less attention has been given to potential long-term complications of TEVAR for BTAI. This paper focuses on these complications, which include progressive aortic expansion with aging, inadequate stent graft characteristics, device durability concerns, long-term radiation exposure concerns from follow-up computed tomography scans, and the potential for (Victims of Modern Imaging Technology VOMIT.

  10. "Elephant trunk" and endovascular stentgrafting : a hybrid approach to the treatment of extensive thoracic aortic aneurysm

    OpenAIRE

    Holubec, Tomás; Raupach, Jan; Dominik, Jan; Vojácek, Jan

    2013-01-01

    A hybrid approach to elephant trunk technique for treatment of thoracic aortic aneurysms combines a conventional surgical and endovascular therapy. Compared to surgery alone, there is a presumption that mortality and morbidity is reduced. We present a case report of a 42-year-old man with a giant aneurysm of the entire thoracic aorta, significant aortic and tricuspid regurgitation and ventricular septum defect. The patient underwent multiple consecutive operations and interventions having, am...

  11. A correlative study of aortic valve rotation angle and thoracic aortic sizes using ECG gated CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saremi, Farhood, E-mail: fsaremi@usc.edu; Cen, Steven; Tayari, Nazila; Alizadeh, Houman; Emami, Amir; Lin, Leah; Fleischman, Fernando

    2017-04-15

    Objective: Various degrees of aortic valve rotation may be seen in individuals with no history of congenital cardiovascular malformations, but its association with aortic sizes has not been studied. Methods: Gated computed tomographic (CT angiograms in 217 patients were studied (66.7 ± 15; 22–97 years old)). Aortic diameters were determined at 5 anatomic locations. The length of the aorta from sinus to left subclavian artery was measured. The angle of valve rotation was recorded by measuring the angle between a line connecting the midpoint of the non-coronary sinus to the anterior commissure and another line along the interatrial septum. Rotation angles were correlated with aortic measurements. Patients were separated into two groups based on aortic sizes and into three groups based on age. The threshold for aortic dilatation was set at maximum ascending aorta diameter ≥40 mm (≥21 mm body surface area [BSA] indexed). Results: No significant difference in rotation angles was seen between the three age groups or between genders. Rotation angles were significantly correlated with maximal, average, and BSA adjustment of the aortic root and ascending aortic measurements. The aortic root angles were significantly different between the dilated versus nondilated aortas. There was no significant association between the rotation angles and age, length of ascending aorta, or diameters of descending aorta. Multivariate adaptive regression splines showed 25° of aortic root rotation as the diagnostic cut off for ascending aorta dilation. Above the 25° rotation, every 10° of increasing rotation was associated with a 3.78 ± 0.87 mm increase in aortic diameter (p < 0.01) and a 1.73 ± 0.25 times increased risk for having a dilated aorta (p < 0.01). Conclusion: Rotation angles of the aortic valve may be an independent non-invasive imaging marker for dilatation of the ascending aorta. Patients with increased rotation angle of the aortic valve may have higher risk for

  12. Thoracic Aorta 3D Hemodynamics in Pediatric and Young Adult Patients With Bicuspid Aortic Valve

    NARCIS (Netherlands)

    Allen, Bradley D.; van Ooij, Pim; Barker, Alex J.; Carr, Maria; Gabbour, Maya; Schnell, Susanne; Jarvis, Kelly B.; Carr, James C.; Markl, Michael; Rigsby, Cynthia; Robinson, Joshua D.

    2015-01-01

    Background: To evaluate the 3D hemodynamics in the thoracic aorta of pediatric and young adult bicuspid aortic valve (BAV) patients. Methods: 4D flow MRI was performed in 30 pediatric and young adult BAV patients (age: 13.9 +/- 4.4 (range: [3.4, 20.7]) years old, M:F = 17:13) as part of this

  13. Cardiovascular Disease in Ageing: An Overview on Thoracic Aortic Aneurysm as an Emerging Inflammatory Disease

    Directory of Open Access Journals (Sweden)

    Calogera Pisano

    2017-01-01

    Full Text Available Medial degeneration associated with thoracic aortic aneurysm and acute aortic dissection was originally described by Erdheim as a noninflammatory lesion related to the loss of smooth muscle cells and elastic fibre fragmentation in the media. Recent evidences propose the strong role of a chronic immune/inflammatory process in aneurysm evocation and progression. The coexistence of inflammatory cells with markers of apoptotic vascular cell death in the media of ascending aorta with aneurysms and type A dissections raises the possibility that activated T cells and macrophages may contribute to the elimination of smooth muscle cells and degradation of the matrix. On the other hand, several inflammatory pathways (including TGF-β, TLR-4 interferon-γ, chemokines, and interferon-γ seem to be involved in the medial degeneration related to aged and dilated aorta. This is an overview on thoracic aortic aneurysm as an emerging inflammatory disease.

  14. Preoperative Evaluation and Endovascular Procedure of Intraoperative Aneurysm Rupture During Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Zha, Bin-Shan, E-mail: binszha2013@163.com; Zhu, Hua-Gang, E-mail: huagzhu@yeah.net; Ye, Yu-Sheng, E-mail: yeyusheng@aliyun.com; Li, Yong-Sheng, E-mail: 872868848@qq.com; Zhang, Zhi-Gong, E-mail: zzgedward@sina.com; Xie, Wen-Tao, E-mail: 345344347@qq.com [The First Affiliated Hospital of Anhui Medical University, Department of Vascular Surgery (China)

    2017-03-15

    Thoracic aortic aneurysms are now routinely repaired with endovascular repair if anatomically feasible because of advantages in safety and recovery. However, intraoperative aneurysm rupture is a severe complication which may have an adverse effect on the outcome of treatment. Comprehensive preoperative assessment and considerate treatment are keys to success of endovascular aneurysm repair, especially during unexpected circumstances. Few cases have reported on intraoperative aortic rupture, which were successfully managed by endovascular treatment. Here, we present a rare case of an intraoperative aneurysm rupture during endovascular repair of thoracic aortic aneurysm with narrow neck and angulated aorta arch (coarctation-associated aneurysm), which was successfully treated using double access route approach and iliac limbs of infrarenal devices.Level of EvidenceLevel 5.

  15. Intentional left subclavian artery coverage during thoracic endovascular aortic repair for traumatic aortic injury.

    Science.gov (United States)

    McBride, Cameron L; Dubose, Joseph J; Miller, Charles C; Perlick, Alexa P; Charlton-Ouw, Kristofer M; Estrera, Anthony L; Safi, Hazim J; Azizzadeh, Ali

    2015-01-01

    Thoracic endovascular aortic repair (TEVAR) is widely used for treatment of traumatic aortic injury (TAI). Stent graft coverage of the left subclavian artery (LSA) may be required in up to 40% of patients. We evaluated the long-term effects of intentional LSA coverage (LSAC) on symptoms and return to normal activity in TAI patients compared with a similarly treated group whose LSA was uncovered (LSAU). Patients were identified from a prospective institutional trauma registry between September 2005 and July 2012. TAI was confirmed using computed tomography angiography. The electronic medical records, angiograms, and computed tomography angiograms were reviewed in a retrospective fashion. In-person or telephone interviews were conducted using the SF-12v2 (Quality Metrics, Lincoln, RI) to assess quality of life. An additional questionnaire was used to assess specific LSA symptoms and the ability to return to normal activities. Data were analyzed by Spearman rank correlation and multiple linear and logistic regression analysis with appropriate transformations using SAS software (SAS Institute, Cary, NC). During the study period, 82 patients (57 men; mean age 40.5 ± 20 years, mean Injury Severity Score, 34 ± 10.0) underwent TEVAR for treatment of TAI. Among them, LSAC was used in 32 (39.5%) and LSAU in 50. A group of the LSAU patients (n = 22) served as matched controls in the analysis. We found no statistically significant difference in SF-12v2 physical health scores (ρ = -0.08; P = .62) between LSAC and LSAU patients. LSAC patients had slightly better mental health scores (ρ = 0.62; P = .037) than LSAU patients. LSAC patients did not have an increased likelihood of experiencing pain (ρ = -0.0056; P = .97), numbness (ρ = -0.12; P = .45), paresthesia (ρ = -0.11; P = .48), fatigue (ρ = -0.066; P = .69), or cramping (ρ = -0.12; P = .45). We found no difference between groups in the ability to return to activities. The mean follow-up time was 3.35 years. Six LSAC

  16. Preoperative evaluation of the artery of adamkiewicz by MR angiography and CT angiography in patients with a thoracic aortic aneurysm

    International Nuclear Information System (INIS)

    Niinuma, Hiroyuki; Ohira, Atsushi; Makita, Shinji; Moriai, Yoshiteru; Hiramori, Katsuhiko; Yoshioka, Kunihiro; Nakajima, Takayuki; Kawazoe, Kohei

    2002-01-01

    Paraplegia is known as an extremely serious and important complication of surgical repair in patients with a thoraco-abdominal aortic aneurysm. It is important to evaluate the artery of Adamkiewicz (AdA) before surgical repair to prevent paraplegia. But the AdA is difficult to visualize by the invasive and hazardous, conventional selective angiography. The aim of this study was to visualize AdA by MR angiography (MRA) and CT angiography (CTA). Twenty-one consecutive patients with a thoracic aortic aneurysm underwent both gadolinium-enhanced, three-dimensional MRA and CTA using multislice helical CT. The AdA was successfully visualized in 15 of the 21 patients (71.4%) by MRA, and in 17 of those 21 patients (80.9%) by CTA. Its continuity was depicted in 12 of 15 patients (80%) by MRA, and in 9 of 17 patients (47%) by CTA. AdA was visualized at 85.7% by MRA or CTA, respectively. This study shows that CTA is a much more sensitive method to detect AdA than MRA. On the other hand, MRA is better to evaluate the continuity of AdA from the descending aorta to the anterior spinal artery, than CTA. Therefore, MRA and CTA are both useful for a preoperative evaluation of AdA and its detailed vascular anatomy from the aorta to the anterior spinal artery. (author)

  17. Society of Thoracic Surgeons Risk Score predicts hospital charges and resource use after aortic valve replacement.

    Science.gov (United States)

    Arnaoutakis, George J; George, Timothy J; Alejo, Diane E; Merlo, Christian A; Baumgartner, William A; Cameron, Duke E; Shah, Ashish S

    2011-09-01

    The impact of Society of Thoracic Surgeons predicted mortality risk score on resource use has not been previously studied. We hypothesize that increasing Society of Thoracic Surgeons risk scores in patients undergoing aortic valve replacement are associated with greater hospital charges. Clinical and financial data for patients undergoing aortic valve replacement at The Johns Hopkins Hospital over a 10-year period (January 2000 to December 2009) were reviewed. The current Society of Thoracic Surgeons formula (v2.61) for in-hospital mortality was used for all patients. After stratification into risk quartiles, index admission hospital charges were compared across risk strata with rank-sum and Kruskal-Wallis tests. Linear regression and Spearman's coefficient assessed correlation and goodness of fit. Multivariable analysis assessed relative contributions of individual variables on overall charges. A total of 553 patients underwent aortic valve replacement during the study period. Average predicted mortality was 2.9% (±3.4) and actual mortality was 3.4% for aortic valve replacement. Median charges were greater in the upper quartile of patients undergoing aortic valve replacement (quartiles 1-3, $39,949 [interquartile range, 32,708-51,323] vs quartile 4, $62,301 [interquartile range, 45,952-97,103], P < .01]. On univariate linear regression, there was a positive correlation between Society of Thoracic Surgeons risk score and log-transformed charges (coefficient, 0.06; 95% confidence interval, 0.05-0.07; P < .01). Spearman's correlation R-value was 0.51. This positive correlation persisted in risk-adjusted multivariable linear regression. Each 1% increase in Society of Thoracic Surgeons risk score was associated with an added $3000 in hospital charges. This is the first study to show that increasing Society of Thoracic Surgeons risk score predicts greater charges after aortic valve replacement. As competing therapies, such as percutaneous valve replacement, emerge to

  18. Case of sudden death following rupture of thoracic aortic aneurysm during “a manual therapy” procedure in the spinal area

    Directory of Open Access Journals (Sweden)

    Aleksandra Kaczorowska

    2015-03-01

    Full Text Available The reported case concerns the rupture of an aneurysm located in the descending part of the thoracic aorta during the procedure of the so-called “spinal adjustment” performed by a chiropractor. A 45-year-old patient with no significant medical history of cardiovascular diseases visited, along with his wife, one of “manual therapy” practices because of back pain. During the procedure, the patient suddenly lost consciousness. Despite cardiopulmonary resuscitation and emergency assistance given by an ambulance team, the patient died. An autopsy revealed that the cause of death was increasing cardiorespiratory failure secondary to bleeding into the lumen of the left pleural cavity following the rupture of pathologically altered thoracic aortic wall.

  19. Spinal Ischemia in Thoracic Aortic Procedures: Impact of Radiculomedullary Artery Distribution.

    Science.gov (United States)

    Kari, Fabian A; Wittmann, Karin; Krause, Sonja; Saravi, Babak; Puttfarcken, Luisa; Förster, Katharina; Rylski, Bartosz; Maier, Sven; Göbel, Ulrich; Siepe, Matthias; Czerny, Martin; Beyersdorf, Friedhelm

    2017-12-01

    The aim of this study was to assess the influence of thoracic anterior radiculomedullary artery (tARMA) distribution on spinal cord perfusion in a thoracic aortic surgical model. Twenty-six pigs (34 ± 3 kg; study group, n = 20; sham group, n = 6) underwent ligation of the left subclavian artery and thoracic segmental arteries. End points were spinal cord perfusion pressure (SCPP), regional spinal cord blood flow (SCBF), and neurologic outcome with an observation time of 3 hours. tARMA distribution patterns tested for an effect on end points included (1) maximum distance between any 2 tARMAs within the treated aortic segment (0 or 1 segment = small-distance group; >1 segment = large-distance group) and (2) distance between the end of the treated aortic segment and the first distal tARMA (at the level of the distal simulated stent-graft end = group 0; gap of 1 or more segments = group ≥1). The number of tARMA ranged from 3 to 13 (mean, 8). In the large-distance group, SCBF dropped from 0.48 ± 0.16 mL/g/min to 0.3 ± 0.08 mL/g/min (p distribution patterns of tARMAs correlate with the degree of SCBF drop and insufficient reactive parenchymal hyperemia in aortic procedures. Individual ARMA distribution patterns along the treated aortic segment could help us predict the individual risk of spinal ischemia. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Endovascular treatment of type II endoleak following thoracic endovascular aortic repair for thoracic aortic aneurysm: Case report of squeeze technique to reach the aneurysmal sac

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hyun Jung; Kim, Chang Won; Lee, Tae Hong; Song, Seung Hwan; Lee, Chung Won; Chung, Sung Woon [Pusan National University Hospital, School of Medicine, Pusan National University, Busan (Korea, Republic of)

    2014-12-15

    Type II endoleaks are common after thoracic endovascular aortic repair (TEVAR). Various strategies are introduced to manage type II endoleaks, such as the use of coils, plugs, or liquid embolic agents (histoacryl, thrombin, onyx, etc.) through a transarterial approach or a direct puncture of the aneurysmal sac. We herein report a case of a type II endoleak caused by reverse blood flow through intercostal artery after TEVAR which was successfully treated with n-butyl cyanoacrylate (histoacryl)-lipiodol mixture by a squeeze technique to reach the aneurismal sac using a microcatheter.

  1. Massive aggrecan and versican accumulation in thoracic aortic aneurysm and dissection.

    Science.gov (United States)

    Cikach, Frank S; Koch, Christopher D; Mead, Timothy J; Galatioto, Josephine; Willard, Belinda B; Emerton, Kelly B; Eagleton, Matthew J; Blackstone, Eugene H; Ramirez, Francesco; Roselli, Eric E; Apte, Suneel S

    2018-03-08

    Proteoglycan accumulation is a hallmark of medial degeneration in thoracic aortic aneurysm and dissection (TAAD). Here, we defined the aortic proteoglycanome using mass spectrometry, and based on the findings, investigated the large aggregating proteoglycans aggrecan and versican in human ascending TAAD and a mouse model of severe Marfan syndrome. The aortic proteoglycanome comprises 20 proteoglycans including aggrecan and versican. Antibodies against these proteoglycans intensely stained medial degeneration lesions in TAAD, contrasting with modest intralamellar staining in controls. Aggrecan, but not versican, was increased in longitudinal analysis of Fbn1mgR/mgR aortas. TAAD and Fbn1mgR/mgR aortas had increased aggrecan and versican mRNAs, and reduced expression of a key proteoglycanase gene, ADAMTS5, was seen in TAAD. Fbn1mgR/mgR mice with ascending aortic dissection and/or rupture had dramatically increased aggrecan staining compared with mice without these complications. Thus, aggrecan and versican accumulation in ascending TAAD occurs via increased synthesis and/or reduced proteolytic turnover, and correlates with aortic dissection/rupture in Fbn1mgR/mgR mice. Tissue swelling imposed by aggrecan and versican is proposed to be profoundly deleterious to aortic wall mechanics and smooth muscle cell homeostasis, predisposing to type-A dissections. These proteoglycans provide potential biomarkers for refined risk stratification and timing of elective aortic aneurysm repair.

  2. Mid-term results of zone 0 thoracic endovascular aneurysm repair after ascending aorta wrapping and supra-aortic debranching in high-risk patients.

    Science.gov (United States)

    Pecoraro, Felice; Lachat, Mario; Hofmann, Michael; Cayne, Neal S; Chaykovska, Lyubov; Rancic, Zoran; Puippe, Gilbert; Pfammatter, Thomas; Mangialardi, Nicola; Veith, Frank J; Bettex, Dominique; Maisano, Francesco; Neff, Thomas A

    2017-06-01

    Surgical repair of aneurysmal disease involving the ascending aorta, aortic arch and eventually the descending aorta is generally associated with significant morbidity and mortality. A less invasive approach with the ascending wrapping technique (WT), supra-aortic vessel debranching (SADB) and thoracic endovascular aneurysm repair (TEVAR) in zone 0 was developed to reduce the associated risk in these patients. During a 10-year period, consecutive patients treated by the ascending WT, SADB and TEVAR in zone 0 were included. All patients were considered at high risk for conventional surgery. Measured outcomes included perioperative deaths and morbidity, maximal aortic transverse diameter (TD) and its postoperative evolution, endoleak, survival, freedom from cardiovascular reinterventions, SADB freedom from occlusion and aortic valve function during follow-up. Median follow-up was 37.4 [mean = 34; range, 0-65; standard deviation (SD) = 20] months. Twenty-six cases were included with a mean age of 71.88 ( r  = 56-87; SD = 8) years. A mean of 2.9 supra-aortic vessels (75) per patient was debranched from the ascending aorta. The mean time interval from WT/SADB and TEVAR was 29 ( r  = 0-204; SD = 48) days. TEVAR was associated with chimney and/or periscope grafts in 6 (23%) patients, and extra-anatomical supra-aortic bypasses were performed in 6 (23%) patients. Perioperative mortality was 7.7% (2/26). Neurological events were registered in 3 (11.5%) cases, and a reintervention was required in 3 (11.5%) cases. After the WT, the ascending diameter remained stable during the follow-up period in all cases. At mean follow-up, significant shrinkage of the arch/descending aorta diameter was observed. A type I/III endoleak occurred in 3 cases. At 5 years, the rates of survival, freedom from cardiovascular reinterventions and SADB freedom from occlusion were 71.7, 82.3 and 96%, respectively. The use of the ascending WT, SADB and TEVAR in selected patients

  3. A rare case of acyanotic congenital heart disease, large patent ductus arteriosus with pre-ductal coarctation of descending thoracic aorta with patent ductus arteriosus closure and extra anatomical bypass grafting

    Directory of Open Access Journals (Sweden)

    Zara Wani

    2017-01-01

    Full Text Available We report a case of 18-year-old female patient with large patent ductus arteriosus (PDA-preductal coarctation of descending thoracic aorta. She underwent large PDA closure with a prosthetic graft from ascending aorta to descending thoracic aorta by mid-sternotomy on cardiopulmonary bypass machine under total hypothermic circulatory arrest.

  4. A rare case of acyanotic congenital heart disease, large patent ductus arteriosus with pre-ductal coarctation of descending thoracic aorta with patent ductus arteriosus closure and extra anatomical bypass grafting.

    Science.gov (United States)

    Wani, Zara; Tiwari, Deepak; Gehlot, Rajeev; Kumar, Deepak; Chhabra, Sushil; Sharma, Meenaxi

    2017-01-01

    We report a case of 18-year-old female patient with large patent ductus arteriosus (PDA)-preductal coarctation of descending thoracic aorta. She underwent large PDA closure with a prosthetic graft from ascending aorta to descending thoracic aorta by mid-sternotomy on cardiopulmonary bypass machine under total hypothermic circulatory arrest.

  5. CT appearance of complications related to thoracic endovascular aortic repair (TEVAR): a pictorial essay

    International Nuclear Information System (INIS)

    Pua, U.; Tay, K.H.; Tan, B.S.; Htoo, M.M.; Sebastian, M.; Sin, K.; Chua, Y.L.

    2009-01-01

    Thoracic endovascular aortic repair (TEVAR) is a recognized treatment for various diseases involving the thoracic aorta. Patients treated with TEVAR require lifelong surveillance for potential complications, with CT being highly utilized in most centres. Endoleak is the most common complication and can be detected using CT. However, other complications such as stent strut perforations and end organ ischemia can also be detected on CT. The purpose of this pictorial essay is to illustrate the CT appearance of post-TEVAR complications encountered in our institution and to highlight their significance. (orig.)

  6. CT appearance of complications related to thoracic endovascular aortic repair (TEVAR): a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Pua, U. [Singapore General Hospital, Department of Diagnostic Radiology, Singapore (Singapore); Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore); Tay, K.H.; Tan, B.S.; Htoo, M.M. [Singapore General Hospital, Department of Diagnostic Radiology, Singapore (Singapore); Sebastian, M. [Singapore General Hospital, Department of General Surgery, Singapore (Singapore); Sin, K.; Chua, Y.L. [National Heart Centre, Department of Cardiothoracic and Vascular Surgery, Singapore (Singapore)

    2009-05-15

    Thoracic endovascular aortic repair (TEVAR) is a recognized treatment for various diseases involving the thoracic aorta. Patients treated with TEVAR require lifelong surveillance for potential complications, with CT being highly utilized in most centres. Endoleak is the most common complication and can be detected using CT. However, other complications such as stent strut perforations and end organ ischemia can also be detected on CT. The purpose of this pictorial essay is to illustrate the CT appearance of post-TEVAR complications encountered in our institution and to highlight their significance. (orig.)

  7. Analysis of transit time flow of the right internal thoracic artery anastomosed to the left anterior descending artery compared to the left internal thoracic artery

    Science.gov (United States)

    Milani, Rodrigo; de Moraes, Daniela; Sanches, Aline; Jardim, Rodrigo; Lumikoski, Thais; Miotto, Gabriela; Santana, Vitor Hugo; Brofman, Paulo Roberto

    2014-01-01

    Introduction We evaluated with transit time flow the performance of the right and left thoracic arteries when used as a graft for the left anterior descending artery. Methods Fifty patients undergoing surgery for myocardial revascularization without cardiopulmonary bypass were divided into two groups. In group A patients received graft of right internal mammary artery to the anterior interventricular branch. In group B patients received graft of left internal mammary artery to the same branch. At the end of the operation the flow was assessed by measuring transit time. Results In group A, mean age was 60.6±9.49 years. The average height and weight of the group was 80.4±10.32 kg and 169.2±6.86 cm. The average number of grafts per patient in this group was 3.28±1.49. The mean flow and distal resistance obtained in right internal thoracic artery was 42.1±23.4 ml/min and 2.8±0.9 respectively. In group B, the mean age was 59.8±9.7 years. The average height and weight of this group was 77.7±14.22 kg and 166.0±8.2 cm. The average number of grafts per patient in this group was 3.08 ±0.82. The mean flow and distal resistance observed in this group was 34.2±19.1 ml/min and 2.0±0.7. There were no deaths in this series. Conclusion Right internal mammary artery presented a similar behavior to left internal mammary artery when anastomosed to the anterior interventricular branch of the left coronary artery. There was no statistical difference between the measured flow obtained between both arteries. PMID:25140463

  8. Increased levels of interleukin-22 in thoracic aorta and plasma from patients with acute thoracic aortic dissection.

    Science.gov (United States)

    Ye, Jing; Wang, Menglong; Jiang, Huimin; Ji, Qingwei; Huang, Ying; Liu, Jianfang; Zeng, Tao; Xu, Yao; Wang, Zhen; Lin, Yingzhong; Wan, Jun

    2017-11-03

    Interleukin (IL)-22 plays important roles in the development of arterial disease, including atherosclerosis and hypertension. However, the relationship between IL-22 and acute thoracic aortic dissection (TAD) remains unknown. Blood samples were collected from patients with chest pain who underwent computed tomography angiography of the thoracic aorta but had no known preoperative diagnosis of coronary artery disease, peripheral artery disease, arthritis, and/or membranous nephropathy. Patients were divided into non-AD (NAD) and TAD groups, and the plasma concentrations of IL-22, IL-6 and tumor necrosis factor (TNF)-α were measured. In addition, aortic tissue samples from acute TAD patients and normal donors were collected, and the expression levels of IL-22 and IL-22 receptor 1 (IL-22R1) were measured. IL-22, IL-6 and TNF-α levels were significantly higher in acute TAD patients than in NAD patients (IL-22, NAD group: 27.0 (19.1, 38.6) pg/ml vs. TAD group: 32.9 (20.6, 58.3) pg/ml, pTAD (OR 1.169, 95% CI 1.069 to 1.277; p=0.001). In addition, compared with aortic tissue of normal controls, TAD aortas showed increased expression of IL-22 and IL-22R1, especially in the torn section (IL-22, non-torn section: 2.8±0.5/HPF vs. torn section 2.8±0.5/HPF, pTAD. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Genetic variants in FBN-1 and risk for thoracic aortic aneurysm and dissection.

    Science.gov (United States)

    Iakoubova, Olga A; Tong, Carmen H; Rowland, Charles M; Luke, May M; Garcia, Veronica E; Catanese, Joseph J; Moomiaie, Remo M; Sotonyi, Peter; Ascady, Gyorgy; Nikas, Demitrios; Dedelias, Panagiotis; Tranquilli, Maryann; Elefteriades, John A

    2014-01-01

    A recent genome wide association study (GWAS) by LeMaire et al. found that two single nucleotide polymorphisms (SNPs), rs2118181 and rs10519177 in the FBN-1 gene (encoding Fibrillin-1), were associated with thoracic aortic dissection (TAD), non-dissecting thoracic aortic aneurysm (TAA), and thoracic aortic aneurysm or dissection (TAAD); the largest effect was observed for the association of rs2118181 with TAD. We investigated whether rs2118181 and rs10519177 were associated with TAD, TAA, and TAAD in the Yale study. The genotypes of rs2118181 and rs10519177 were determined for participants in the Yale study: 637 TAAD cases (140 TAD, 497 TAA) and 275 controls from the United States, Hungary, and Greece. The association of the genotypes with TAD, TAA and TAAD were assessed using logistic regression models adjusted for sex, age, study center and hypertension. In the Yale study, rs2118181 was associated with TAD: compared with non-carriers, carriers of the risk allele had an unadjusted odds ratio for TAD of 1.80 (95% CI 1.15-2.80) and they had odds ratio for TAD of 1.87 (95% CI 1.09-3.20) after adjusting for sex, age, study center and hypertension. We did not find significant differences in aortic size, a potential confounder for TAD, between rs2118181 risk variant carriers and non-carriers: mean aortic size was 5.56 (95% CI: 5.37-5.73) for risk variant carriers (CC+CT) and was 5.48 (95% CI: 5.36-5.61) for noncarriers (TT) (p = 0.56). rs2118181 was not associated with TAA or TAAD. rs10519177 was not associated with TAD, TAA, or TAAD in the Yale study. Thus, the Yale study provided further support for the association of the FBN-1 rs2118181SNP with TAD.

  10. The Benefits of Internal Thoracic Artery Catheterization in Patients With Chronic Abdominal Aortic Occlusion

    International Nuclear Information System (INIS)

    Ilic, Nikola; Davidovic, Lazar; Koncar, Igor; Dragas, Marko; Markovic, Miroslav; Colic, Momcilo; Cinara, Ilijas

    2011-01-01

    Occlusion of the abdominal aorta may be caused by an embolic lesion, but more commonly by thrombotic disease at the aortoiliac area, progressing retrograde. However, the visualization of the distal run-off via internal thoracic-epigastric inferior artery collateral channel may be a very important diagnostic tool, especially in countries with poor technical equipment. This study was designed to show the benefit of the selective internal thoracic angiography in cases with complete aortic occlusion. We present 30 patients with chronic aortic abdominal occlusion who were submitted to the transaxillary aortography and selective ITA angiography with purpose of distal run off evaluation. Angiographic evaluation was performed by two independent radiologists according to previously defined classification. Good angiographic score via internal thoracic angiography by first observer was achieved in 19 (63.3%) patients and in 18 (60%) by a second observer. Transaxillary aortography showed inferior results: good angiographic score by the first observer in six (20%) patients and by the second observer in three (3%) patients. Low extremity run-off is better visualized during internal thoracic angiography than during transaxillary aortography.

  11. Risk model of thoracic aortic surgery in 4707 cases from a nationwide single-race population through a web-based data entry system: the first report of 30-day and 30-day operative outcome risk models for thoracic aortic surgery.

    Science.gov (United States)

    Motomura, Noboru; Miyata, Hiroaki; Tsukihara, Hiroyuki; Takamoto, Shinichi

    2008-09-30

    The objective of this study was to collect integrated data from nationwide hospitals using a web-based national database system to build up our own risk model for the outcome from thoracic aortic surgery. The Japan Adult Cardiovascular Surgery Database was used; this involved approximately 180 hospitals throughout Japan through a web-based data entry system. Variables and definitions are almost identical to the STS National Database. After data cleanup, 4707 records were analyzed from 97 hospitals (between January 1, 2000, and December 31, 2005). Mean age was 66.5 years. Preoperatively, the incidence of chronic lung disease was 11%, renal failure was 9%, and rupture or malperfusion was 10%. The incidence of the location along the aorta requiring replacement surgery (including overlapping areas) was: aortic root, 10%; ascending aorta, 47%; aortic arch, 44%; distal arch, 21%; descending aorta, 27%; and thoracoabdominal aorta, 8%. Raw 30-day and 30-day operative mortality rates were 6.7% and 8.6%, respectively. Postoperative incidence of permanent stroke was 6.1%, and renal failure requiring dialysis was 6.7%. OR for 30-day operative mortality was as follows: emergency or salvage, 3.7; creatinine >3.0 mg/dL, 3.0; and unexpected coronary artery bypass graft, 2.6. As a performance metric of the risk model, C-index of 30-day and 30-day operative mortality was 0.79 and 0.78, respectively. This is the first report of risk stratification on thoracic aortic surgery using a nationwide surgical database. Although condition of these patients undergoing thoracic aortic surgery was much more serious than other procedures, the result of this series was excellent.

  12. “ELEPHANT TRUNK” AND ENDOVASCULAR STENTGRAFTING – A HYBRID APPROACH TO THE TREATMENT OF EXTENSIVE THORACIC AORTIC ANEURYSM

    Directory of Open Access Journals (Sweden)

    Tomáš Holubec

    2013-01-01

    Full Text Available A hybrid approach to elephant trunk technique for treatment of thoracic aortic aneurysms combines a conventional surgical and endovascular therapy. Compared to surgery alone, there is a presumption that mortality and morbidity is reduced. We present a case report of a 42-year-old man with a giant aneurysm of the entire thoracic aorta, significant aortic and tricuspid regurgitation and ventricular septum defect. The patient underwent multiple consecutive operations and interventions having, among others, finally replaced the entire thoracic aorta with the use of the hybrid elephant trunk technique.

  13. Endovascular stenting of a chronic ruptured type B thoracic aortic dissection, a second chance: a case report.

    Science.gov (United States)

    Arshad, Ali; Khan, Sumaira L; Whitaker, Simon C; Macsweeney, Shane T

    2008-02-07

    We aim to highlight the need for awareness of late complications of endovascular thoracic aortic stenting and the need for close follow-up of patients treated by this method. We report the first case in the English literature of an endovascular repair of a previously stented, ruptured chronic Stanford type B thoracic aortic dissection re-presenting with a type III endoleak of the original repair. Endovascular thoracic stenting is now a widely accepted technique for the treatment of thoracic aortic dissection and its complications. Long term follow up is necessary to ensure that late complications are identified and treated appropriately. In this case of type III endoleak, although technically challenging, endovascular repair was feasible and effective.

  14. Multidisciplinary Treatment Approach for Prosthetic Vascular Graft Infection in the Thoracic Aortic Area

    Science.gov (United States)

    Watanabe, Yoshinori

    2015-01-01

    Prosthetic vascular graft infection in the thoracic aortic area is a rare but serious complication. Adequate management of the complication is essential to increase the chance of success of open surgery. While surgical site infection is suggested as the root cause of the complication, it is also related to decreased host tolerance, especially as found in elderly patients. The handling of prosthetic vascular graft infection has been widely discussed to date. This paper mainly provides a summary of literature reports published within the past 5 years to discuss issues related to multidisciplinary treatment approaches, including surgical site infection, timing of onset, diagnostic methods, causative pathogens, auxiliary diagnostic methods, antibiotic treatment, anti-infective structures of vascular prostheses, surgical treatment, treatment strategy against infectious aortic aneurysms, future surgical treatment, postoperative systemic therapy, and antimicrobial stewardship. A thorough understanding of these issues will enable us to prevent prosthetic vascular graft infection in the thoracic aortic area as far as possible. In the event of its occurrence, the early introduction of appropriate treatment is expected to cure the disease without worsening of the underlying pathological condition. PMID:26356686

  15. Aortic rupture complicating a fracture of an ankylosed thoracic spine. A case report.

    Science.gov (United States)

    Savolaine, E R; Ebraheim, N A; Stitgen, S; Jackson, W T

    1991-11-01

    A 34-year-old man was injured in a motorcycle accident and suffered both aortic rupture and thoracic spinal fracture, complicated by an underlying undetected ankylosing spondylitis. The latter disease can affect the integrity of vascular and spinal structure. Aortography is recommended as a high priority for the patient in an unstable cardiovascular condition requiring a definitive diagnosis. Aortic rupture and thoracic spine fracture may occur from high energy deceleration trauma. Motor vehicle passenger and pedestrian injuries are most commonly involved, although airline accidents and high falls also generate some cases. Mediastinal widening, displacement of esophagus and trachea, apical dissection of blood, and, especially, paravertebral pleural space widening are common to both injuries. Whereas most mediastinal hematomas are nonaortic in origin, a combined injury must be considered because clinical features may also overlap. These include hypotension (hypovolemic or spinal shock), paraplegia, and severe back pain. In light of the high mortality and time constraints associated with aortic rupture, immediate diagnostic resolution is necessary for appropriate management and priority of investigation.

  16. Prevention of paraplegia after endovascular exclusion for stanford B thoracic aortic dissection aneurism

    International Nuclear Information System (INIS)

    Feng Rui; Jing Zaiping; Bao Junmin; Zhao Zhiqing; Zhao Jun; Feng Xiang; Lu Qingsheng; Huang Cheng

    2003-01-01

    Objective: To assess the prophylactic measures of paraplegia and paralysis after endovascular graft exclusion (EVE) for Stanford B thoracic aortic dissections (TAD). Methods: The records of 116 consecutive patients undergoing endovascular TAD repair from 1998 to 2001 were retrospectively reviewed. Steroids were administrated postoperatively in high risk patients likely to be candidates for paraplegia or paralysis. Results: No paraplegia or paralysis occurred postoperatively in all cases, including the patient undergone selective spinal artery angiography (SSAA). Conclusions: Transluminal repair can avoid spinal cord ischemia due to aortic cross-clamping, there is still a risk of spinal cord injury caused by occlusion of intercostal arteries under the cover of endograft. A combination of the prophylactic measures, including SSAA and steroids, have been able to reduce the risk of paraplegia and paralysis. A graft-stent of appropriate length is the key point of this procedure

  17. When and how should we manage thoracic aortic injuries in the modern era?

    Science.gov (United States)

    Bottet, Benjamin; Bouchard, François; Peillon, Christophe; Baste, Jean-Marc

    2016-12-01

    A best evidence topic in cardiovascular surgery was written according to a structured protocol. The question addressed was what are the optimum treatment modality and timing of intervention for blunt thoracic aortic injury (BTAI) in the modern era? Of the 697 papers found using the reported search, 14 (5 meta-analyses, 2 prospective and 7 retrospective studies) represented the best evidence to answer the clinical question. The author, journal, country, date of publication, patient group studied, study type, relevant outcomes, results and weakness of these papers are tabulated. All five meta-analyses reported a reduction in mortality with thoracic endovascular aortic repair (TEVAR) compared with open repair (OR), but only four found the same benefit on paraplegia rate. Similarly, the two prospective and four retrospective studies showed significantly lower mortality with TEVAR than with OR. Only one study (a meta-analysis) reported a significantly lower stroke rate with TEVAR than with OR, whereas the 13 others reported a similar or even higher stroke rate. Other complication rates were identical. Four studies demonstrated that non-operative management (NOM) as a treatment option for BTAI was associated with increased mortality, even if it has declined in recent years. One study emphasized that some cases with minimal aortic injuries (Grade I and II on CT scan) could benefit from NOM. Regarding the timing of repair, only three studies analysed outcomes of delayed repair and reported significantly lower mortality than for early repair. We conclude that with lower mortality and similar overall complications including paraplegia but higher stroke rate, TEVAR is the most suitable treatment for BTAI in the modern era, where expertise exists, especially for cases of multiple associated injuries and in the older age group. Delayed aortic repair can be proposed based on CT scan analysis, but emergent repair should still be advocated for imminent free aortic rupture. NOM

  18. Risk factors and early outcomes of acute renal injury after thoracic aortic endograft repair for type B aortic dissection

    Directory of Open Access Journals (Sweden)

    Luo S

    2017-08-01

    Full Text Available Songyuan Luo,* Huanyu Ding,* Jianfang Luo, Wei Li, Bing Ning, Yuan Liu, Wenhui Huang, Ling Xue, Ruixin Fan, Jiyan Chen Cardiology Department, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of Coronary Heart Disease Prevention, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, China *These authors contributed equally to this work Background: Thoracic endovascular aortic repair (TEVAR has become an emerging treatment modality for acute type B aortic dissection (TBAD patients in recent years. The risk factors and impacts of acute kidney injury (AKI after percutaneous TEVAR, however, have not been widely established.Methods: We retrospectively studied the clinical records of 305 consecutive patients who admitted to our institution and had TEVAR for TBAD between December 2009 and June 2013. The patients were routinely monitored for their renal functions preoperatively until 7 days after TEVAR. The Kidney Disease Improving Global Guidelines (KDIGO criteria were used for AKI.Results: Of the total 305 consecutive patients, 84 (27.5% developed AKI after TEVAR, comprising 66 (21.6% patients in KDIGO stage 1, 6 (2.0% patients in stage 2 and 12 (3.9% patients in stage 3. From the logistic regression analysis, systolic blood pressure (SBP on admission >140 mmHg (odds ratio [OR], 2.288; 95% CI, 1.319–3.969 and supra-aortic branches graft bypass hybrid surgery (OR, 3.228; 95% CI, 1.526–6.831 were independent risk factors for AKI after TEVAR. Local anesthesia tended to be a protective factor (OR, 0.563; 95% CI, 0.316–1.001. The preoperative renal function, angiotensin-converting enzyme inhibitor/angiotensin receptor blocker or statin administration, volume of contrast agent, range of TBAD and false lumen involving renal artery were not associated with post-operation AKI. The in-hospital mortality and major adverse events were markedly increased with the occurrence of AKI (7.1% vs 0.9%, P=0

  19. Zone zero thoracic endovascular aortic repair: A proposed modification to the classification of landing zones.

    Science.gov (United States)

    Roselli, Eric E; Idrees, Jay J; Johnston, Douglas R; Eagleton, Matthew J; Desai, Milind Y; Svensson, Lars G

    2018-04-01

    Endovascular stent-grafting provides an alternative treatment option for high-risk patients with ascending aortic disease. The feasibility of this approach has been demonstrated before. We assess the updated experience with ascending thoracic endovascular aortic repair and propose a modification of the landing zone classification based on the outcomes. From 2006 to 2016, 39 patients deemed very high risk for open replacement underwent endovascular repair of ascending aorta for acute type A dissection (12, 31%), intramural hematoma (2, 5%), pseudoaneurysm (22, 56%), and chronic dissection suture line entry tear (3, 8%). Ascending thoracic endovascular aortic repair was performed in 36 patients. In 3 patients with pseudoaneurysm, occluder devices were used. Computed tomography imaging analysis was performed, and the extent of aortic pathology was designated by segmental proximity to the left ventricle. Segmental anatomy of the proximal aorta was designed as zone 0A from the annulus to the distal margin of highest coronary, 0B extends from above the coronary to the distal margin of right pulmonary artery, and 0C extends from the right pulmonary artery border to the innominate artery. Multivariable time to event Cox regression analysis was performed to predict mortality, and long-term survival was estimated using the Kaplan-Meier method. Operative mortality was 13%; all 5 deaths occurred after emergency ascending thoracic endovascular aortic repair for type A dissection. Other complications included stroke in 4 patients (10%), myocardial infarction in 2 patients (5%), tracheostomy in 2 patients (5%), and dialysis in 2 patients (5%). In patients with acute type A dissection, the ascending pathology extended into zone 0A in 10 (71%) and 0B in 4 (29%). Among those with pseudoaneurysm, the location of the defect was in 0B in 11 (50%), 0C in 10 (45%), and 0A in 1. Among the patients with chronic dissection, the defect was located in 0C in all 3 (100%). After multivariable

  20. Characterization of dendritic morphology and neurotransmitter phenotype of thoracic descending propriospinal neurons after complete spinal cord transection and GDNF treatment

    Science.gov (United States)

    Deng, Lingxiao; Ruan, Yiwen; Chen, Chen; Frye, Christian Corbin; Xiong, Wenhui; Jin, Xiaoming; Jones, Kathryn; Sengelaub, Dale; Xu, Xiao-Ming

    2016-01-01

    After spinal cord injury (SCI), poor regeneration of damaged axons of the central nervous system (CNS) causes limited functional recovery. This limited spontaneous functional recovery has been attributed, to a large extent, to the plasticity of propriospinal neurons, especially the descending propriospinal neurons (dPSNs). Compared with the supraspinal counterparts, dPSNs have displayed significantly greater regenerative capacity, which can be further enhanced by glial cell line-derived neurotrophic factor (GDNF). In the present study, we applied a G-mutated rabies virus (G-Rabies) co-expressing green fluorescence protein (GFP) to reveal Golgi-like dendritic morphology of dPSNs. We also investigated the neurotransmitters expressed by dPSNs after labeling with a retrograde tracer Fluoro-Gold (FG). dPSNs were examined in animals with sham injuries or complete spinal transections with or without GDNF treatment. Bilateral injections of G-Rabies and FG were made into the 2nd lumbar (L2) spinal cord at 3 days prior to a spinal cord transection performed at the 11th thoracic level (T11). The lesion gap was filled with Gelfoam containing either saline or GDNF in the injury groups. Four days post-injury, the rats were sacrificed for analysis. For those animals receiving G-rabies injection, the GFP signal in the T7–9 spinal cord was visualized via 2-photon microscopy. Dendritic morphology from stack images was traced and analyzed using a Neurolucida software. We found that dPSNs in sham injured animals had a predominantly dorsal-ventral distribution of dendrites. Transection injury resulted in alterations in the dendritic distribution with dorsal-ventral retraction and lateral-medial extension. Treatment with GDNF significantly increased the terminal dendritic length of dPSNs. The density of spine-like structures was increased after injury, and treatment with GDNF enhanced this effect. For the group receiving FG injections, immunohistochemistry for glutamate, choline

  1. Nicotinamide Phosphoribosyltransferase in Smooth Muscle Cells Maintains Genome Integrity, Resists Aortic Medial Degeneration, and Is Suppressed in Human Thoracic Aortic Aneurysm Disease.

    Science.gov (United States)

    Watson, Alanna; Nong, Zengxuan; Yin, Hao; O'Neil, Caroline; Fox, Stephanie; Balint, Brittany; Guo, Linrui; Leo, Oberdan; Chu, Michael W A; Gros, Robert; Pickering, J Geoffrey

    2017-06-09

    The thoracic aortic wall can degenerate over time with catastrophic consequences. Vascular smooth muscle cells (SMCs) can resist and repair artery damage, but their capacities decline with age and stress. Recently, cellular production of nicotinamide adenine dinucleotide (NAD + ) via nicotinamide phosphoribosyltransferase (Nampt) has emerged as a mediator of cell vitality. However, a role for Nampt in aortic SMCs in vivo is unknown. To determine whether a Nampt-NAD + control system exists within the aortic media and is required for aortic health. Ascending aortas from patients with dilated aortopathy were immunostained for NAMPT, revealing an inverse relationship between SMC NAMPT content and aortic diameter. To determine whether a Nampt-NAD + control system in SMCs impacts aortic integrity, mice with Nampt -deficient SMCs were generated. SMC- Nampt knockout mice were viable but with mildly dilated aortas that had a 43% reduction in NAD + in the media. Infusion of angiotensin II led to aortic medial hemorrhage and dissection. SMCs were not apoptotic but displayed senescence associated-ß-galactosidase activity and upregulated p16, indicating premature senescence. Furthermore, there was evidence for oxidized DNA lesions, double-strand DNA strand breaks, and pronounced susceptibility to single-strand breakage. This was linked to suppressed poly(ADP-ribose) polymerase-1 activity and was reversible on resupplying NAD + with nicotinamide riboside. Remarkably, we discovered unrepaired DNA strand breaks in SMCs within the human ascending aorta, which were specifically enriched in SMCs with low NAMPT. NAMPT promoter analysis revealed CpG hypermethylation within the dilated human thoracic aorta and in SMCs cultured from these tissues, which inversely correlated with NAMPT expression. The aortic media depends on an intrinsic NAD + fueling system to protect against DNA damage and premature SMC senescence, with relevance to human thoracic aortopathy. © 2017 American Heart

  2. Improvement of thoracic aortic vasoreactivity by continuous and intermittent exercise in high-fat diet-induced obese rats.

    Science.gov (United States)

    Liu, Hongpeng; Yang, Zhen; Hu, Jian; Luo, Yan; Zhu, Lingqin; Yang, Huifang; Li, Guanghua

    2015-07-01

    The aim of the present study was to explore the effects of continuous and intermittent exercise on the thoracic aortic vasoreactivity and free radical metabolism in rats fed with a high-fat diet (HD). Sprague-Dawley (SD) rats were randomly divided into four groups (n=8, each group): Conventional diet (CD), HD, HD with continuous exercise (HCE) and HD with intermittent exercise (HIE). HCE rats swam once/day for 90 min; HIE rats performed swimming exercises 3 times/day, 30 min each time with an interval of 4 h. In these two groups, the exercise was conducted 5 days a week for 8 weeks. Rats in the CD and HD groups were fed without swimming training. At the end of the exercise, all the rats were sacrificed and the blood, thoracic aorta and myocardium were collected immediately. The thoracic aortic vasoreactivity, the plasma total cholesterol (TC), triglyceride (TG), high-density lipoprotein (HDL), low-density lipoprotein (LDL), superoxide dismutase (SOD), malondialdehyde (MDA) and vascular endothelial nitric oxide synthase (eNOS) gene expression were measured. Compared to the control group, in the HD group the enhanced contractile response of the thoracic aortic rings to noradrenaline (NA) was observed (Pimprove the activity of the thoracic aorta in obese rats, which may be associated with enhanced antioxidant enzyme activity and reduced free radical generating. Additionally, intermittent exercise is better than the continuous exercise in improving the thoracic aorta vasoreactivity.

  3. Hybrid repair of a very late, post-aortic coarctation surgery thoracic aneurysm: a case report

    Directory of Open Access Journals (Sweden)

    Tilea Ioan

    2012-08-01

    Full Text Available Abstract Introduction Local aneurysms after surgical repair of coarctation of the aorta occur mainly in patients surgically treated by Dacron patch plasty during adulthood. The management of these patients is always problematic, with frequent complications and increased mortality rates. Percutaneous stent-graft implantation avoids the need for surgical reintervention. Case presentation We report a case involving the hybrid treatment by stent-graft implantation and transposition of the left subclavian artery to the left common carotid artery of an aneurysmal dilatation of the thoracic aorta that occurred in a 64-year-old Caucasian man, operated on almost 40 years earlier with a Dacron patch plasty for aortic coarctation. Our patient presented to our facility for evaluation with back pain and shortness of breath after minimal physical effort. A physical examination revealed stony dullness to percussion of the left posterior thorax, with no other abnormalities. The results of chest radiography, followed by contrast-enhanced computed tomography and aortography, led to a diagnosis of giant aortic thoracic aneurysm. Successful treatment of the aneurysm was achieved by percutaneous stent-graft implantation combined with transposition of the left subclavian artery to the left common carotid artery. His post-procedural recovery was uneventful. Three months after the procedure, computed tomography showed complete thrombosis of the excluded aneurysm, without any clinical signs of left lower limb ischemia or new onset neurological abnormalities. Conclusions Our patient’s case illustrates the clinical outcomes of surgical interventions for aortic coarctation. However, the very late appearance of a local aneurysm is rather unusual. Management of such cases is always difficult. The decision-making should be multidisciplinary. A hybrid approach was considered the best solution for our patient.

  4. [Midterm results of thoracic aortic dissection endovascular repair in conjunctions with the location of Adamkiewicz artery].

    Science.gov (United States)

    Jia, Ying-bin; Li, Jian; Su, Yong-hui; Ma, Jie-fei; Guan, Xiao-dong; Zhang, Bai-meng

    2012-10-23

    To evaluate the effects of using longer xenografts in conjunctions with the location of Adamkiewicz artery (AKA) on midterm outcomes of endovascular treatment for thoracic aortic dissection. From March 2005 to September 2011, 217 patients with type B dissection were recruited. There were 143 males and 74 females with a mean age of 65 ± 11 years. Among them, 43 patients were from Fifth Affiliated Hospital of Sun Yat-Sen University while another 174 patients from Affiliated Zhongshan Hospital of Fudan University. They were divided into 2 groups according to whether AKA was identified or not pre-operatively. Endovascular repairs were performed for all patients. Distal landing levels of xenografts were recorded. The thrombosis of false lumen and the complications of spinal cord injury and endoleak were analyzed. AKA was detected in 121 (55.8%) patients (group A) but not in 96 (44.2%) patients (group B). According to the levels of AKA, the patients of group A obtained the stabilization of affected thoracic aorta over a longer distance. And the ratio of patients with distal landing levels at T8-T10 was significantly higher than in group B (59.5% vs 12.5%, χ² = 49.85, P < 0.01). Also, during the follow-up period of 7.3 months, the ratio of patients with total thrombosis of false lumen in group A was significantly higher than that in group B (32.1% vs 19.1%, χ² = 4.34, P < 0.05). During the endovascular repair of thoracic aortic dissection, selecting a longer device may provide a better structural stability of affected aorta and promote false lumen thrombosis.

  5. The utility of chest X-ray as a screening tool for blunt thoracic aortic injury.

    Science.gov (United States)

    Gutierrez, Adam; Inaba, Kenji; Siboni, Stefano; Effron, Zachary; Haltmeier, Tobias; Jaffray, Paul; Reddy, Sravanthi; Lofthus, Alexander; Benjamin, Elizabeth; Dubose, Joseph; Demetriades, Demetrios

    2016-01-01

    The early and accurate identification of patients with blunt thoracic aortic injury (BTAI) remains a challenge. Traditionally, a portable AP chest X-ray (CXR) is utilized as the initial screening modality for BTAI, however, there is controversy surrounding its sensitivity. The purpose of this study was to assess the sensitivity of CXR as a screening modality for BTAI. After IRB approval, all adult (≥18 yo) blunt trauma patients admitted to LAC+USC (01/2011-12/2013) who underwent CXR and chest CT were retrospectively reviewed. Final radiology attending CXR readings were reviewed for mediastinal abnormalities (widened mediastinum, mediastinal to chest width ratio greater than 0.25, irregular aortic arch, blurred aortic contour, opacification of the aortopulmonary window, and apical pleural haematoma) suggestive of aortic injury. Chest CT final attending radiologist readings were utilized as the gold standard for diagnosis of BTAI. The primary outcome analyzed was CXR sensitivity. A total of 3728 patients were included in the study. The majority of patients were male (72.6%); mean age was 43 (SD 20). Median ISS was 9 (IQR 4-17) and median GCS was 15 (IQR 14-15). The most common mechanism of injury was MVC (48.0%), followed by fall (20.6%), and AVP (16.9%). The total number of CXRs demonstrating a mediastinal abnormality was 200 (5.4%). Widened mediastinum was present on 191 (5.1%) of CXRs, blurred aortic contour on 10 (0.3%), and irregular aortic arch on 4 (0.1%). An acute aortic injury confirmed by chest CT was present in 17 (0.5%) patients. Only 7 of these with CT-confirmed BTAI had a mediastinal abnormality identified on CXR, for a sensitivity of 41% (95% CI: 19-67%). The results from this study suggest that CXR alone is not a reliable screening modality for BTAI. A combination of screening CXR and careful consideration of other factors, such as mechanism of injury, will be required to effectively discriminate between those who should and should not undergo chest

  6. Role of contrast-enhanced helical CT in the evaluation of acute thoracic aortic injuries after blunt chest trauma

    International Nuclear Information System (INIS)

    Scaglione, M.; Pinto, A.; Pinto, F.; Romano, L.; Ragozzino, A.; Grassi, R.

    2001-01-01

    The purpose of this retrospective study was to determine the value of contrast-enhanced helical CT for detecting and managing acute thoracic aortic injury (ATAI). Between June 1995 and February 2000, 1419 consecutive chest CT examinations were performed in the setting of major blunt trauma. The following CT findings were considered indicative of ATAI: intimal flap; pseudoaneurysm; contour irregularity; lumen abnormality; and extravasation of contrast material. On the basis of these direct findings no further diagnostic investigations were performed. Isolated mediastinal hematoma on CT scans was considered an indirect sign of ATAI: In these cases, thoracic aortography was performed even if CT indicated normal aorta. Seventy-seven patients had abnormal CT scans: Among the 23 patients with direct CT signs, acute thoracic aortic injuries was confirmed at thoracotomy in 21. Two false-positive cases were observed. The 54 remaining patients had isolated mediastinal hematoma without aortic injuries at CT and corresponding negative angiograms. The 1342 patients with negative CT scans were included in the 8-month follow-up program and did not show any adverse sequela based on clinical and radiographic criteria. Contrast-enhanced helical CT has a critical role in the exclusion of thoracic aortic injuries in patient with major blunt chest trauma and prevents unnecessary thoracic aortography. Direct CT signs of ATAI do not require further diagnostic investigations to confirm the diagnosis: Isolated aortic bands or contour vessel abnormalities should be first considered as possible artifacts or related to non-traumatic etiologies especially when mediastinal hematoma is absent. In cases of isolated mediastinal hematoma other possible sources of bleeding should be considered before directing patients to thoracic aortography. (orig.)

  7. Valve-sparing aortic root replacement in patients with Marfan syndrome enrolled in the National Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions.

    Science.gov (United States)

    Song, Howard K; Preiss, Liliana R; Maslen, Cheryl L; Kroner, Barbara; Devereux, Richard B; Roman, Mary J; Holmes, Kathryn W; Tolunay, H Eser; Desvigne-Nickens, Patrice; Asch, Federico M; Milewski, Rita K; Bavaria, Joseph; LeMaire, Scott A

    2014-05-01

    The long-term outcomes of aortic valve-sparing (AVS) root replacement in Marfan syndrome (MFS) patients remain uncertain. The study aim was to determine the utilization and outcomes of AVS root replacement in MFS patients enrolled in the Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions (GenTAC). At the time of this analysis, 788 patients with MFS were enrolled in the GenTAC Registry, of whom 288 had undergone aortic root replacement. Patients who had undergone AVS procedures were compared to those who had undergone aortic valve replacement (AVR). AVS root replacement was performed in 43.5% of MFS patients, and the frequency of AVS was increased over the past five years. AVS patients were younger at the time of surgery (31.0 versus 36.3 years, p = 0.006) and more likely to have had elective rather than emergency surgery compared to AVR patients, in whom aortic valve dysfunction and aortic dissection was the more likely primary indication for surgery. After a mean follow up of 6.2 +/- 3.6 years, none of the 87 AVS patients had required reoperation; in contrast, after a mean follow up of 10.5 +/- 7.6 years, 11.5% of AVR patients required aortic root reoperation. Aortic valve function has been durable, with 95.8% of AVS patients having aortic insufficiency that was graded as mild or less. AVS root replacement is performed commonly among the MFS population, and the durability of the aortic repair and aortic valve function have been excellent to date. These results justify a continued use of the procedure in an elective setting. The GenTAC Registry will be a useful resource to assess the long-term durability of AVS root replacement in the future.

  8. Valve Sparing Aortic Root Replacement in Patients with Marfan Syndrome Enrolled in the National Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions

    Science.gov (United States)

    Song, Howard K.; Preiss, Liliana R.; Maslen, Cheryl L.; Kroner, Barbara; Devereux, Richard B.; Roman, Mary J.; Holmes, Kathryn W.; Tolunay, H. Eser; Desvigne-Nickens, Patrice; Asch, Federico M.; Milewski, Rita K.; Bavaria, Joseph; LeMaire, Scott A.

    2016-01-01

    Background The long-term outcomes of aortic valve sparing (AVS) root replacement in Marfan syndrome (MFS) patients remain uncertain. We sought to determine the utilization and outcomes of AVS root replacement in MFS patients enrolled in the Registry of Genetically Triggered Thoracic Aortic Aneurysms and Cardiovascular Conditions (GenTAC). Methods At the time of this analysis, 788 patients with MFS were enrolled in the GenTAC Registry, of whom 288 have undergone aortic root replacement. Patients who have undergone AVS procedures were compared to those who have undergone aortic valve replacing (AVR) procedures. Results AVS root replacement was performed in 43.5% of MFS patients and the frequency of AVS increased over the past 5 years. AVS patients were younger at the time of surgery (31.0 vs. 36.3 years, p=0.006) and more likely to have had elective rather than emergency surgery compared to AVR patients. AVR patients were more likely to have had aortic valve dysfunction and aortic dissection as a primary indication for surgery. After mean follow-up of 6.2 (SD=3.6) years, none of the 87 AVS patients have required reoperation; in contrast, after mean follow up of 10.5 (SD=7.6) years, 11.5% of AVR patients have required aortic root reoperation. Aortic valve function has been durable with 95.8% of AVS patients with aortic insufficiency graded as mild or less. Conclusions AVS root replacement is performed commonly in the MFS population. The durability of the aortic repair and aortic valve function have been excellent to date. These results justify the continued use of the procedure in the elective setting. The GenTAC Registry will be a useful resource to assess the long-term durability of AVS root replacement in the future. PMID:25296451

  9. Evaluation of chemokine receptors (CCRs expression on peripheral blood T-lymphocyte subsets in patients with thoracic aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Kaushal Kishore Tiwari

    2016-03-01

    Full Text Available Background & Objectives: Mortality and morbidity from the complication of aortic aneurysm remain very high. Aortic size index, which classify thoracic aortic aneurysm patients in three risk groups for aortic rupture prediction. Recent data support that aortic wall remodeling is a dynamic process with active involvement of the chronic inflammation and immunological system. Aim of our study is to evaluate expression level of chemokine receptors known to be involved in the T-cells migration and to correlate them with aortic size index. Materials & Methods: Total 20 patients undergoing surgery for ascending aortic aneurysm and/or aortic valve surgery were enrolled. Aortic size index was calculated. Preoperatively blood samples collected. By flowcytometry and dual parameter dot plot technology percentage of positivity of CCR5 on these T-cell subsets were quantified. Results: Mean age of the patients was 67±5.93 years. Majority of patients had hypertension. Mean ascending aortic diameter was 42.1±8.14 mm. Mean Aortic size Index was 22.21±3.38 mm/m2. A statistical significance has observed between aortic size index and the expression of CCR5 on total CD4 positive T-cells (p-0.0949, and between aortic size index and CCR5 expression on the total CD3 positive T-cells (p-0.0293. Significant correlation observed between ASI and CCR5 expression on the CD8+/CD3+ T-cell subset (p-0.0183. Similarly, strong positive relationship between ASI and the expression of CCR5 on the cytotoxic CD28-/CD4+ T-cell subset (p-0.0055. Activated state of cytotoxic CD28-/CD4+ cell also correlated with aortic size index (p-0.0668.Conclusion: We conclude that T-cell mediated cytotoxic mechanism driven by CCR5 play an important role in the pathophysiology of the thoracic aortic aneurysm.JCMS Nepal. 2016;12(1:23-27.

  10. Innovative postmarket device evaluation using a quality registry to monitor thoracic endovascular aortic repair in the treatment of aortic dissection.

    Science.gov (United States)

    Beck, Adam W; Lombardi, Joseph V; Abel, Dorothy B; Morales, J Pablo; Marinac-Dabic, Danica; Wang, Grace; Azizzadeh, Ali; Kern, John; Fillinger, Mark; White, Rodney; Cronenwett, Jack L; Cambria, Richard P

    2017-05-01

    United States Food and Drug Administration (FDA)-mandated postapproval studies have long been a mainstay of the continued evaluation of high-risk medical devices after initial marketing approval; however, these studies often present challenges related to patient/physician recruitment and retention. Retrospective single-center studies also do not fully represent the spectrum of real-world performance nor are they likely to have a sufficiently large enough sample size to detect important signals. In recent years, The FDA Center for Devices and Radiological Health has been promoting the development and use of patient registries to advance infrastructure and methodologies for medical device investigation. The FDA 2012 document, "Strengthening the National System for Medical Device Post-market Surveillance," highlighted registries as a core foundational infrastructure when linked to other complementary data sources, including embedded unique device identification. The Vascular Quality Initiative (VQI) thoracic endovascular aortic repair for type B aortic dissection project is an innovative method of using quality improvement registries to meet the needs of device evaluation after market approval. Here we report the organization and background of this project and highlight the innovation facilitated by collaboration of physicians, the FDA, and device manufacturers. This effort used an existing national network of VQI participants to capture patients undergoing thoracic endovascular aortic repair for acute type B aortic dissection within a registry that aligns with standard practice and existing quality efforts. The VQI captures detailed patient, device, and procedural data for consecutive eligible cases under the auspices of a Patient Safety Organization (PSO). Patients were divided into a 5-year follow-up group (200 acute; 200 chronic dissections) and a 1-year follow-up group (100 acute; 100 chronic). The 5-year cohort required additional imaging details, and the 1-year

  11. Heart failure and sudden cardiac death in heritable thoracic aortic disease caused by pathogenic variants in the SMAD3 gene.

    Science.gov (United States)

    Backer, Julie De; Braverman, Alan C

    2018-05-01

    Predominant cardiovascular manifestations in the spectrum of Heritable Thoracic Aortic Disease include by default aortic root aneurysms- and dissections, which may be associated with aortic valve disease. Mitral- and tricuspid valve prolapse are other commonly recognized features. Myocardial disease, characterized by heart failure and/or malignant arrhythmias has been reported in humans and in animal models harboring pathogenic variants in the Fibrillin1 gene. Description of clinical history of three cases from one family in Ghent (Belgium) and one family in St. Louis (US). We report on three cases from two families presenting end-stage heart failure (in two) and lethal arrhythmias associated with moderate left ventricular dilatation (in one). All three cases harbor a pathogenic variant in the SMAD3 gene, known to cause aneurysm osteoarthritis syndrome, Loeys-Dietz syndrome type 3 or isolated Heritable Thoracic Aortic Disease. These unusual presentations warrant awareness for myocardial disease in patients harboring pathogenic variants in genes causing Heritable Thoracic Aortic Disease and indicate the need for prospective studies in larger cohorts. © 2018 The Authors. Molecular Genetics & Genomic Medicine published by Wiley Periodicals, Inc.

  12. Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

    International Nuclear Information System (INIS)

    Chan, Gabriel; Quek, Lawrence Hwee Han; Tan, Glenn Leong Wei; Pua, Uei

    2016-01-01

    BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

  13. Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Gabriel, E-mail: dr.changabriel@gmail.com; Quek, Lawrence Hwee Han, E-mail: lawrence-quek@ttsh.com.sg [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore); Tan, Glenn Leong Wei, E-mail: glenn-tan@ttsh.com.sg [Tan Tock Seng Hospital, Department of General Surgery (Singapore); Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2016-07-15

    BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

  14. The implantation of separating aortic stent-graft into the canine thoracic aorta: an experimental study

    International Nuclear Information System (INIS)

    Xia Jinguo; Shi Haibin; Yang Zhengqiang; Li Chao; Liu Sheng; Zu Qingquan; Li Linsun

    2011-01-01

    Objective: to assess the technical feasibility of implanting separating stent-graft into the canine thoracic aorta and to study its biocompatibility. Methods: Twelve adult dogs were randomly and equally divided into three groups. The right femoral artery was cut open, through which the separating stent-graft was inserted and deployed in the canine thoracic aorta, with the proximal end of the graft being quite close to the origin of the left subclavian artery. the technical feasibility of the deployment process was assessed. Angiography was performed at 4, 8 and 12 weeks after stent-graft placement to evaluate the position and patency of the stent-graft. Then the dogs were sacrificed and the specimens were collected for pathologic study. Both gross and microscopic examinations were made to evaluate the fixation of the stent-graft with the vessel wall, the endothelialization of stent-graft surface and the pathologic changes of the vascular wall. Results: A total of ten separating stent-grafts were successfully deployed in the canine thoracic aorta, no migration or deformation occurred. One dog died of massive bleeding due to the rupture of the right femoral artery which occurred when the delivery system containing the inner bare stent was inserted through the right femoral artery. Death occurred in another dog as a result of the ascending aorta rupture caused by the migration of outer-layer stent-graft. Angiography was conducted at 4, 8 and 12 weeks after stent-graft placement. No migration, deformation, rupture or stenosis of the implanted stent-grafts were observed. The formation of intima on the inner surface of the bare stent appeared at 4 weeks, which became more and more obvious with the time passing, and at 12 weeks complete endothelialization of stent-graft surface was observed. Conclusion: Technically, it is feasible to deploy the separating aortic stent-graft into the canine thoracic aorta. Moreover, the separating aortic stent-graft carries excellent

  15. Endovascular graft exclusion in treating thoracic aortic dissection: a report of 25 cases

    International Nuclear Information System (INIS)

    Chen Wei; Yang Jianyong; Zhuang Wenquan; Guo Wenbo; Li Heping; Zhong Lizhen; Huang Qiuping

    2003-01-01

    Objective: To evaluate the usefulness and efficacy of endovascular graft exclusion (EVGE) in treating thoracic aortic dissection (TAD). Methods: Twenty-five cases of TAD, including 24 cases of Standford B and 1 case of A, were treated by EVGE. The clinical outcome and morphological changes of the lesions were analyzed during a 2-20 months' follow-up. Results: Procedures were technically successful in all 25 cases, while a total of 28 stent-grafts were deployed (3 cases with 2 stent-grafts in each). Complete disappearance of the false lumen or remarkable decrease of the endoleak was noted on the angiograms after stent placement. No severe procedure-related complication was observed, and thrombosis of the false lumen was noted during the follow-up. Conclusion: EVGE is effective and reliable in treating TAD, especially for patients with sub-acute or chronic courses

  16. Ruptured thoracic aortic aneurysm in patient with systemic lupus erythematosus Aneurisma roto da aorta descendente em paciente com lúpus eritematoso sistêmico

    Directory of Open Access Journals (Sweden)

    Daniel Oliveira De Conti

    2011-03-01

    Full Text Available It is reported a ruptured descending thoracic aortic aneurysm in a 25-year-old systemic lupus erythematosus woman who underwent 19 years steroid therapy. She was treated with 2 endovascular stent-grafts, discharged from hospital 13 days after the procedure in good health. Three months later she returned with hemorrhagic shock due to high digestive hemorrhage secondary to an aortic-esophageal fistula. She underwent to an open emergency surgery, and died during the post-operative period.Paciente de 25 anos, do sexo feminino, portadora de lúpus eritematoso sistêmico, fazendo uso de corticoesteroide havia 19 anos, deu entrada em unidade de emergência com aneurisma roto de aorta torácica descendente. Foi submetida a tratamento endovascular com 2 stents, recebeu alta hospitalar no 13º dia de pós-operatório, em boas condições de saúde. Três meses depois, retornou em choque hemorrágico secundário a hemorragia digestiva alta. Feito o diagnóstico de fístula aorto-esofágica, foi submetida à cirurgia aberta de emergência, indo a óbito durante o período pós-operatório.

  17. Management of aorto-esophageal fistula secondary after thoracic endovascular aortic repair: a review of literature.

    Science.gov (United States)

    Uno, Kaname; Koike, Tomoyuki; Takahashi, Seiichi; Komazawa, Daisuke; Shimosegawa, Tooru

    2017-10-01

    Aorto-esophageal fistula (AEF) is a rare and lethal entity, and the difficulty of making diagnosis of AEF is well-known. As promising results in the short-term effectiveness of thoracic endovascular aortic repair (TEVAR) promote its usage, the occurrence of AEF after TEVAR (post-TEVAR AEF) increases as one of the major complications. Therefore, we provide a review concerning the management strategy of post-TEVAR AEF. Although its representative symptom was reported as the triad of mid-thoracic pain and sentinel hematemesis followed by massive hematemesis, the symptom-free interval between sentinel hemorrhage and massive exsanguination is unpredictable. However, the physiological condition represents a surgical contraindication. Accordingly, early diagnosis is important, but either CT or esophago-gastro-duodenoscopy rarely depicts a typical image. The formation of post-TEVAR AEF might be associated with the infection of micro-organisms, which is uncontrollable with anti-biotic administration. The current first-line strategy is combination therapy as follows, (1) to control bleeding by TEVAR in the urgent phase, and (2) radical debridement and aortic/esophageal re-construction in the semi-urgent phase. In view of the high mortality and morbidity rate, it is proposed that the choice in treatment strategies might be affected by patient`s condition, size of the wall defects and the etiology of AEF. Practically, we should keep in mind the importance of making an early diagnosis and, once a suspicious symptom has occurred in a patient with a history of TEVAR, the existence of post-TEVAR AEF should be suspected. A prospective registry together with more developed technologies will be needed to establish a future strategy.

  18. Importance of designated thoracic trauma surgeons in the management of traumatic aortic transection.

    Science.gov (United States)

    Albrink, M H; Rodriguez, E; England, G J; McKeown, P P; Hurst, J M; Rosemurgy, A S

    1994-04-01

    The medical literature is replete with reports on traumatic aortic transection. These reports have delineated many factors regarding the morbidity and high mortality of this ominous injury. Most reports are reviews of the collective experience of a single institution over a period of years. It is likely that many authors writing on the subject of traumatic aortic transection have no experience with operative repair of the lesion. There has been debate about the various techniques of primary repair versus graft insertion, as well as the question of whether cardiopulmonary bypass is superior to the "clamp and sew" methods. No studies have directly examined the skills of individual surgeons with respect to outcome. We present the results of a study from a university-affiliated level I trauma center in which the outcomes from various groups of surgeons were compared over a 5-year period. The information in this study strongly suggests that designated thoracic trauma surgeons who are promptly available and have dedicated interests in trauma patients achieve better results.

  19. LncRNA Expression Profile of Human Thoracic Aortic Dissection by High-Throughput Sequencing.

    Science.gov (United States)

    Sun, Jie; Chen, Guojun; Jing, Yuanwen; He, Xiang; Dong, Jianting; Zheng, Junmeng; Zou, Meisheng; Li, Hairui; Wang, Shifei; Sun, Yili; Liao, Wangjun; Liao, Yulin; Feng, Li; Bin, Jianping

    2018-01-01

    In this study, the long non-coding RNA (lncRNA) expression profile in human thoracic aortic dissection (TAD), a highly lethal cardiovascular disease, was investigated. Human TAD (n=3) and normal aortic tissues (NA) (n=3) were examined by high-throughput sequencing. Bioinformatics analyses were performed to predict the roles of aberrantly expressed lncRNAs. Quantitative real-time polymerase chain reaction (qRT-PCR) was applied to validate the results. A total of 269 lncRNAs (159 up-regulated and 110 down-regulated) and 2, 255 mRNAs (1 294 up-regulated and 961 down-regulated) were aberrantly expressed in human TAD (fold-change> 1.5, PTAD than in NA. The predicted binding motifs of three up-regulated lncRNAs (ENSG00000248508, ENSG00000226530, and EG00000259719) were correlated with up-regulated RUNX1 (R=0.982, PTAD. These findings suggest that lncRNAs are novel potential therapeutic targets for human TAD. © 2018 The Author(s). Published by S. Karger AG, Basel.

  20. Thoracic aortic dissection and rupture in conotruncal cardiac defects: A population-based study.

    Science.gov (United States)

    Frischhertz, Benjamin P; Shamszad, Pirouz; Pedroza, Claudia; Milewicz, Dianna M; Morris, Shaine A

    2015-04-01

    Although the risk of thoracic aortic dissection and rupture (TAD) is well-known in bicuspid aortic valve (BAV), the risk of TAD in other congenital heart diseases (CHD), particularly conotruncal lesions like tetralogy of Fallot (TOF), truncus arteriosus, D-transposition of the great arteries (D-TGA), and double outlet right ventricle is currently unknown. The primary purpose of this study was to describe TAD in conotruncal CHD, and the secondary purpose was to explore whether an association exists between TAD and conotruncal CHD. Using the Texas Inpatient Public Use Data File, an administrative database of all Texas hospitalizations, including >37.9 million hospitalizations from January 1999 through June 2012, 12,016 cases of TAD and 214 cases of TAD in CHD were identified. The most common lesions were BAV (42%), atrial septal defect (21%), aortic coarctation (7%), ventricular septal defect (6%), and patent ductus arteriosus (4%). Three patients with TOF, 2 with D-TGA, and 1 with truncus arteriosus were admitted with TAD. An exploratory case-control study in patients older than 1 year using multilevel logistic regression models to evaluate the association between CHD and TAD that controlled for known TAD risk factors demonstrated a significant association between TAD and BAV (OR 10, 95% CI 8.2-13) but not coarctation of the aorta or any conotruncal lesion. TAD in conotruncal CHD is exquisitely rare. In our hospitalized population, there was no increased occurrence of TAD in conotruncal CHD above what would be expected in the rest of the hospitalized population. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Dynamic autophagic activity affected the development of thoracic aortic dissection by regulating functional properties of smooth muscle cells

    International Nuclear Information System (INIS)

    Wang, Yang; Zhao, Zhi-Min; Zhang, Guan-Xin; Yang, Fan; Yan, Yan; Liu, Su-Xuan; Li, Song-Hua; Wang, Guo-Kun; Xu, Zhi-Yun

    2016-01-01

    The aortic medial degeneration is the key histopathologic feature of Thoracic aortic dissection (TAD). The aim of this study was to identify the change of autophagic activity in the aortic wall during TAD development, and to explore the roles of autophagy on regulating functional properties of smooth muscle cells (SMCs). Firstly, compared with control group (n = 11), the increased expression of autophagic markers Beclin1 and LC3 was detected in the aortic wall from TAD group (n = 23) by immunochemistry and western blot. We found that more autophagic vacuoles were present in the aortic wall of TAD patients using Transmission electron microscopy. Next, autophagic activity was examined in AD mice model established by β-aminopropionitrile fumarate (BAPN) and angiotensin II. Immunochemistry proved that autophagic activity was dynamically changed during AD development. Beclin1 and LC3 were detected up-regulated in the aortic wall in the second week after BAPN feeding, earlier than the fragmentation or loss of elastic fibers. When AD occurred in the 4th week, the expression of Beclin1 and LC3 began to decrease, but still higher than the control. Furthermore, autophagy was found to inhibit starvation-induced apoptosis of SMCs. Meanwhile, blockage of autophagy could suppress PDGF-induced phenotypic switch of SMCs. Taken together, autophagic activity was dynamically changed in the aortic wall during TAD development. The abnormal autophagy could regulate the functional properties of aortic SMCs, which might be the potential pathogenesis of TAD. - Highlights: • Autophagy is up-regulated in aorta wall from thoracic aorta dissection (TAD) patient. • Autophagic activity is dynamically changed during TAD development. • Dynamically change of autophagy is associated with pathological process of TAD. • Autophagy participate in the development of TAD by regulating function of SMCs.

  2. Intraoperative use of low-dose recombinant activated factor VII during thoracic aortic operations.

    Science.gov (United States)

    Andersen, Nicholas D; Bhattacharya, Syamal D; Williams, Judson B; Fosbol, Emil L; Lockhart, Evelyn L; Patel, Mayur B; Gaca, Jeffrey G; Welsby, Ian J; Hughes, G Chad

    2012-06-01

    Numerous studies have supported the effectiveness of recombinant activated factor VII (rFVIIa) for the control of bleeding after cardiac procedures; however safety concerns persist. Here we report the novel use of intraoperative low-dose rFVIIa in thoracic aortic operations, a strategy intended to improve safety by minimizing rFVIIa exposure. Between July 2005 and December 2010, 425 consecutive patients at a single referral center underwent thoracic aortic operations with cardiopulmonary bypass (CPB); 77 of these patients received intraoperative low-dose rFVIIa (≤60 μg/kg) for severe coagulopathy after CPB. Propensity matching produced a cohort of 88 patients (44 received intraoperative low-dose rFVIIa and 44 controls) for comparison. Matched patients receiving intraoperative low-dose rFVIIa got an initial median dose of 32 μg/kg (interquartile range [IQR], 16-43 μg/kg) rFVIIa given 51 minutes (42-67 minutes) after separation from CPB. Patients receiving intraoperative low-dose rFVIIa demonstrated improved postoperative coagulation measurements (partial thromboplastin time 28.6 versus 31.5 seconds; p=0.05; international normalized ratio, 0.8 versus 1.2; pproduct transfusions (2.5 versus 5.0 units; p=0.05) compared with control patients. No patient receiving intraoperative low-dose rFVIIa required postoperative rFVIIa administration or reexploration for bleeding. Rates of stroke, thromboembolism, myocardial infarction, and other adverse events were equivalent between groups. Intraoperative low-dose rFVIIa led to improved postoperative hemostasis with no apparent increase in adverse events. Intraoperative rFVIIa administration in appropriately selected patients may correct coagulopathy early in the course of refractory blood loss and lead to improved safety through the use of smaller rFVIIa doses. Appropriately powered randomized studies are necessary to confirm the safety and efficacy of this approach. Copyright © 2012 The Society of Thoracic Surgeons

  3. Familial Thoracic Aortic Aneurysm with Dissection Presenting as Flash Pulmonary Edema in a 26-Year-Old Man

    Directory of Open Access Journals (Sweden)

    Sabry Omar

    2014-01-01

    Full Text Available We are reporting a case of familial thoracic aortic aneurysm and dissection in a 26-year-old man with no significant past medical history and a family history of dissecting aortic aneurysm in his mother at the age of 40. The patient presented with cough, shortness of breath, and chest pain. Chest X-ray showed bilateral pulmonary infiltrates. CT scan of the chest showed a dissection of the ascending aorta. The patient underwent aortic dissection repair and three months later he returned to our hospital with new complaints of back pain. CT angiography showed a new aortic dissection extending from the left carotid artery through the bifurcation and into the iliac arteries. The patient underwent replacement of the aortic root, ascending aorta, total aortic arch, and aortic valve. The patient recovered well postoperatively. Genetic studies of the patient and his children revealed no mutations in ACTA2, TGFBR1, TGFBR2, TGFB2, MYH11, MYLK, SMAD3, or FBN1. This case report focuses on a patient with familial TAAD and discusses the associated genetic loci and available screening methods. It is important to recognize potential cases of familial TAAD and understand the available screening methods since early diagnosis allows appropriate management of risk factors and treatment when necessary.

  4. Application of rapid artificial cardiac pacing in thoracic endovascular aortic repair in aged patients

    Directory of Open Access Journals (Sweden)

    Chen J

    2013-12-01

    Full Text Available Jun Chen,1,* Wenhui Huang,2,* Songyuan Luo,2,* Dahao Yang,1 Zhengrong Xu,1 Jianfang Luo21Department of Angiocardiopathy, Affiliated Baoan Hospital of Southern Medical University, Shenzhen City, People's Republic of China; 2Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, People's Republic of China*These authors contributed equally to this workObjective: To compare the safety, efficacy, and impact on stent graft positioning between rapid artificial cardiac pacing (RACP, induced hypotension and sodium nitroprusside (SNP induced hypotension during thoracic endovascular aortic repair (TEVAR for Stanford B aortic dissection.Methods: One hundred and sixty-eight patients, who were diagnosed with Stanford B aortic dissection and who underwent selective TEVAR in Guangdong General Hospital and the People's Hospital of Baoan District, Shenzhen, People's Republic of China, were enrolled in this study. Patients were randomly divided into a RACP group (n=77 and a SNP group (n=91. During localization and deployment of the stent graft, hypotension was induced by RACP or intravenous SNP, according to randomization. Hemodynamics, landing precision (deviation from planned placement site, duration of procedure, renal function, neurocognitive function, and incidence of endoleaks and paraplegia/hemiplegia were compared. Except for methods of inducing hypotension, TEVAR was performed according to the same protocol in each group.Results: RACP was successfully performed in all patients assigned to the RACP group. Compared with the SNP group, blood pressure was significantly lower (43±5 versus 81±6 mmHg, P=0.003 and the restoration time of blood pressure and the operation duration were significantly shorter (7±2 versus 451±87 seconds, P<0.001; 87±15 versus 106±18 minutes, P<0.001, respectively in the RACP group. Stent graft localization/deployment was more precise in the RACP

  5. Delayed endovascular aortic repair is associated with reduced in-hospital mortality in patients with blunt thoracic aortic injury.

    Science.gov (United States)

    Marcaccio, Christina L; Dumas, Ryan P; Huang, Yanlan; Yang, Wei; Wang, Grace J; Holena, Daniel N

    2018-02-13

    The traditional approach to stable blunt thoracic aortic injury (BTAI) endorsed by the Society for Vascular Surgery is early (<24 hours) thoracic endovascular aortic repair (TEVAR). Recently, some studies have shown improved mortality in stable BTAI patients repaired in a delayed manner (≥24 hours). However, the indications for use of delayed TEVAR for BTAI are not well characterized, and its overall impact on the patient's survival remains poorly understood. We sought to determine whether delayed TEVAR is associated with a decrease in mortality compared with early TEVAR in this population. We conducted a retrospective cohort study of adult patients with BTAI (International Classification of Diseases, Ninth Revision diagnosis code 901.0) who underwent TEVAR (International Classification of Diseases, Ninth Revision procedure code 39.73) from 2009 to 2013 using the National Sample Program data set. Missing physiologic data were imputed using chained multiple imputation. Patients were parsed into groups based on the timing of TEVAR (early, <24 hours, vs delayed, ≥24 hours). The χ 2 , Mann-Whitney, and Fisher exact tests were used to compare baseline characteristics and outcomes of interest between groups. Multivariable logistic regression for mortality was performed that included all variables significant at P ≤ .2 in univariate analyses. A total of 2045 adult patients with BTAI were identified, of whom 534 (26%) underwent TEVAR. Patients with missing data on TEVAR timing were excluded (n = 27), leaving a total of 507 patients for analysis (75% male; 69% white; median age, 40 years [interquartile range, 27-56 years]; median Injury Severity Score [ISS], 34 [interquartile range, 26-41]). Of these, 378 patients underwent early TEVAR and 129 underwent delayed TEVAR. The two groups were similar with regard to age, sex, race, ISS, and presenting physiology. Mortality was 11.9% in the early TEVAR group vs 5.4% in the delayed group, with the early group

  6. Problems and prospects of managing thoracic aortic aneurysm at the Nnamdi Azikiwe University Teaching Hospital, Nnewi, Nigeria.

    Science.gov (United States)

    Chianakwana, Gabriel U; Odike, Maxy A C; Nwofor, Alexander M E

    2004-03-01

    The objective of this report is to highlight the problems encountered in managing thoracic aortic aneurysm in a third-generation teaching hospital serving a purely rural community in the heartland of Anambra State, in the southeastern part of Nigeria. This report also proffers solutions aimed at assisting in providing better care for patients afflicted with this condition. From time to time, patients present with vascular diseases, including aneurysm, but the condition is only occasionally suspected and sparingly investigated. This is a report of two cases within the setting of the Nnamdi Azikiwe University Teaching Hospital (NAUTH), Nnewi Nigeria. After the death of these two patients, one of whom was a member of the staff of the hospital, post mortem examinations revealed that they had died of ruptured thoracic aortic aneurysm. Their medical records were retrieved from the Medical Records Department and reviewed with the aim of analyzing their clinical features and management in the light of the unexpected post-mortem examination results. The survey of the patient records revealed that the diagnosis of thoracic aortic aneurysm was not suspected in either patient even though both had symptoms pointing to this condition. The staff member was a 55-year old man and the other patient was a 31-year old woman in her 30th week of pregnancy. We conclude by drawing the attention of medical practitioners in our community to the fact that thoracic aortic aneurysms are probably more common than we thought. Only a high index of suspicion will lead to clinical diagnosis and treatment.

  7. Computational predictions of damage propagation preceding dissection of ascending thoracic aortic aneurysms.

    Science.gov (United States)

    Mousavi, S Jamaleddin; Farzaneh, Solmaz; Avril, Stéphane

    2018-04-01

    Dissections of ascending thoracic aortic aneurysms (ATAAs) cause significant morbidity and mortality worldwide. They occur when a tear in the intima-media of the aorta permits the penetration of the blood and the subsequent delamination and separation of the wall in 2 layers, forming a false channel. To predict computationally the risk of tear formation, stress analyses should be performed layer-specifically and they should consider internal or residual stresses that exist in the tissue. In the present paper, we propose a novel layer-specific damage model based on the constrained mixture theory, which intrinsically takes into account these internal stresses and can predict appropriately the tear formation. The model is implemented in finite-element commercial software Abaqus coupled with user material subroutine. Its capability is tested by applying it to the simulation of different exemplary situations, going from in vitro bulge inflation experiments on aortic samples to in vivo overpressurizing of patient-specific ATAAs. The simulations reveal that damage correctly starts from the intimal layer (luminal side) and propagates across the media as a tear but never hits the adventitia. This scenario is typically the first stage of development of an acute dissection, which is predicted for pressures of about 2.5 times the diastolic pressure by the model after calibrating the parameters against experimental data performed on collected ATAA samples. Further validations on a larger cohort of patients should hopefully confirm the potential of the model in predicting patient-specific damage evolution and possible risk of dissection during aneurysm growth for clinical applications. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Time-resolved three-dimensional magnetic resonance velocity mapping of chronic thoracic aortic dissection. A preliminary investigation

    International Nuclear Information System (INIS)

    Amano, Yasuo; Sekine, Tetsuro; Tanaka, Keiji; Takagi, Ryo; Kumita, Shinichiro; Suzuki, Yuriko

    2011-01-01

    The blood flow patterns of chronic thoracic aortic dissection are complicated, and their clinical significance remains unknown. We evaluated the technical and clinical potentials of time-resolved 3-dimensional (3D) magnetic resonance (MR) velocity mapping for assessing these patterns. We used data collected from time-resolved 3D phase-contrast MR imaging of 16 patients with chronic thoracic aortic dissection to generate time-resolved 3D MR velocity mapping that included 3D streamline and path line. We investigated blood flow patterns of this disease in the mapping and compared them with the morphological changes of the patent false lumen. Time-resolved 3D MR velocity mapping visualized rapid flow at the entry and in the true lumen immediately distal to the entry. We observed slower helical or laminar flow in the patent false lumen. In patients with disease progression, slower helical flow following rapid entry jet collided with the outer wall of the false lumen and was also observed in a growing ulcer-like projection. We showed the potential of time-resolved 3D MR velocity mapping for visualizing pathologic flow patterns related to chronic thoracic aortic dissection. (author)

  9. The effects of aprotinin on blood product transfusion associated with thoracic aortic surgery requiring deep hypothermic circulatory arrest.

    LENUS (Irish Health Repository)

    Seigne, P W

    2012-02-03

    OBJECTIVE: To compare the effects of aprotinin on blood product use and postoperative complications in patients undergoing thoracic aortic surgery requiring deep hypothermic circulatory arrest. DESIGN: A retrospective study. SETTING: A university hospital. PARTICIPANTS: Nineteen patients who underwent elective or urgent thoracic aortic surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The total number of units of packed red blood cells, fresh frozen plasma, and platelets was significantly less in the group that received aprotinin (p = 0.01, 0.04, and 0.01). The intraoperative transfusion of packed red blood cells and platelets, collection and retransfusion of cell saver, and postoperative transfusion of fresh frozen plasma were also significantly less in the aprotinin group (p = 0.01, 0.02, 0.01, and 0.05). No patient in either group sustained renal dysfunction or a myocardial infarction. Two patients who had not received aprotinin suffered from chronic postoperative seizures, and one patient who had received aprotinin sustained a perioperative stroke. CONCLUSIONS: Low-dose aprotinin administration significantly decreases blood product transfusion requirements in the setting of thoracic aortic surgery requiring deep hypothermic circulatory arrest, and it does not appear to be associated with renal or myocardial dysfunction.

  10. Structure of the Elastin-Contractile Units in the Thoracic Aorta and How Genes That Cause Thoracic Aortic Aneurysms and Dissections Disrupt This Structure.

    Science.gov (United States)

    Karimi, Ashkan; Milewicz, Dianna M

    2016-01-01

    The medial layer of the aorta confers elasticity and strength to the aortic wall and is composed of alternating layers of smooth muscle cells (SMCs) and elastic fibres. The SMC elastin-contractile unit is a structural unit that links the elastin fibres to the SMCs and is characterized by the following: (1) layers of elastin fibres that are surrounded by microfibrils; (2) microfibrils that bind to the integrin receptors in focal adhesions on the cell surface of the SMCs; and (3) SMC contractile filaments that are linked to the focal adhesions on the inner side of the membrane. The genes that are altered to cause thoracic aortic aneurysms and aortic dissections encode proteins involved in the structure or function of the SMC elastin-contractile unit. Included in this gene list are the genes encoding protein that are structural components of elastin fibres and microfibrils, FBN1, MFAP5, ELN, and FBLN4. Also included are genes that encode structural proteins in the SMC contractile unit, including ACTA2, which encodes SMC-specific α-actin and MYH11, which encodes SMC-specific myosin heavy chain, along with MYLK and PRKG1, which encode kinases that control SMC contraction. Finally, mutations in the gene encoding the protein linking integrin receptors to the contractile filaments, FLNA, also predispose to thoracic aortic disease. Thus, these data suggest that functional SMC elastin-contractile units are important for maintaining the structural integrity of the aorta. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  11. Regeneration of descending spinal axons after transection of the thoracic spinal cord during early development in the North American opossum, Didelphis virginiana.

    Science.gov (United States)

    Martin, G F; Terman, J R; Wang, X M

    2000-11-15

    Opossums are born in an immature, fetal-like state, making it possible to lesion their spinal cord early in development without intrauterine surgery. When the thoracic spinal cord of the North American opossum, Didelphis virginiana, is transected on postnatal day 5, and injections of Fast Blue (FB) are made caudal to the lesion site 30-40 days or 6 months later, neurons are labeled in all of the spinal and supraspinal areas that are labeled after comparable injections in age-matched, unlesioned controls. Double-labeling studies document that regeneration of cut axons contributes to growth of axons through the lesion site and behavioral studies show that animals lesioned on postnatal day 5 use their hindlimbs in normal appearing locomotion as adults. The critical period for developmental plasticity of descending spinal axons extends to postnatal day 26, although axons which grow through the lesion site become fewer in number and more restricted as to origin with increasing age. Animals lesioned between postnatal day 12 and 26 use the hindlimbs better than animals lesioned as adults, but hindlimb function is markedly abnormal and uncoordinated with that of the forelimbs. We conclude that restoration of anatomical continuity occurs after transection of the spinal cord in developing opossums, that descending axons grow through the lesion site, that regeneration of cut axons contributes to such growth, and that animals lesioned early enough in development have relatively normal motor function as adults.

  12. Fate of patients with spinal cord ischemia complicating thoracic endovascular aortic repair.

    Science.gov (United States)

    DeSart, Kenneth; Scali, Salvatore T; Feezor, Robert J; Hong, Michael; Hess, Philip J; Beaver, Thomas M; Huber, Thomas S; Beck, Adam W

    2013-09-01

    Spinal cord ischemia (SCI) is a potentially devastating complication of thoracic endovascular aortic repair (TEVAR) that can result in varying degrees of short-term and permanent disability. This study was undertaken to describe the clinical outcomes, long-term functional impact, and influence on survival of SCI after TEVAR. A retrospective review of all TEVAR patients at the University of Florida from 2000 to 2011 was performed to identify individuals experiencing SCI, defined by any new lower extremity neurologic deficit not attributable to another cause. SCI was dichotomized into immediate or delayed onset, with immediate onset defined as SCI noted upon awakening from anesthesia, and delayed characterized as a period of normal function, followed by development of neurologic injury. Ambulatory status was determined using database query, record review, and phone interviews with patients and/or family. Mortality was estimated using life-table analysis. A total of 607 TEVARs were performed for various indications, with 57 patients (9.4%) noted to have postoperative SCI (4.3% permanent). SCI patients were more likely to be older (63.9 ± 15.6 vs 70.5 ± 11.2 years; P = .002) and have a number of comorbidities, including chronic obstructive pulmonary disease, hypertension, dyslipidemia, and cerebrovascular disease (P impact on postdischarge FI or long-term mortality. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  13. [Case of neuroleptic malignant syndrome following open heart surgery for thoracic aortic aneurysm with parkinson's disease].

    Science.gov (United States)

    Shinoda, Maiko; Sakamoto, Mik; Shindo, Yuki; Ando, Yumi; Tateda, Takeshi

    2013-12-01

    An 80-year-old woman with Parkinson's disease was scheduled for open heart surgery to repair thoracic aortic aneurysm. Parkinson's symptoms were normally treated using oral levodopa (200 mg), selegiline-hydrochloride (5 mg), bromocriptine-mesilate (2 mg), and amantadine-hydrochloride (200 mg) daily. On the day before surgery, levodopa 50mg was infused intravenously. Another 25 mg of levodopa was infused immediately after surgery. Twenty hours later, the patient developed tremors, heyperventilation, but no obvious muscle rigidity. Two days after surgery, the patient exhibited high fever, hydropoiesis, elevated creatine kinase, and a rise in blood leukocytes. She was diagnosed with neuroleptic malignant syndrome. She was intubated, and received dantrolene sodium. Symptoms of neuroleptic malignant syndrome disappeared on the fourth postoperative day. The stress of open heart surgery, specifically extracorporeal circulation and concomitant dilution of levodopa, triggered neuroleptic malignant syndrome in this patient. Parkinson's patients require higher doses of levodopa prior to surgery to compensate and prevent neuroleptic malignant syndrome after surgery.

  14. Infective endocarditis and thoracic aortic disease: A review on forgotten psychological aspects.

    Science.gov (United States)

    Suárez Bagnasco, Mariana; Núñez-Gil, Iván J

    2017-07-26

    To summarize the current evidence on psychological issues in thoracic aortic disease (TAD) and infective endocarditis (IE) setting. We performed a narrative review about psychological issues in adults with IE and TAD. Through the electronic databases, PubMed and PsycINFO, we searched full manuscripts in English and published until September 1, 2014. We found sixteen studies exploring psychological issues in patients with IE (six studies) and in TAD (ten papers). Psychological issues assessed were quality of life, depression, anxiety and posttraumatic stress disorder. Quality of life was explored in IE (four papers) and in TAD (eight papers). Depression and anxiety were analyzed in TAD only (five papers). Post-traumatic stress disorder was assessed in IE (one study). Quality of life was found impaired in three of four studies about IE and in three of eight studies about TAD. Posttraumatic stress disorder was present in 11% and was associated with lower levels of quality of life in IE patients. In TAD patients, anxiety and depression levels after different invasive interventions did not differ. Sixteen studies report about psychological issues in IE and TAD. Most of them explore quality of life and to a less extent anxiety and depression.

  15. Thoracic Stent Graft Implantation for Aortic Coarctation with Patent Ductus Arteriosus via Retroperitoneal Iliac Approach in the Presence of Small Sized Femoral Artery

    Directory of Open Access Journals (Sweden)

    Ozge Korkmaz

    2016-01-01

    Full Text Available Endovascular stent graft implantation is a favorable method for complex aortic coarctation accompanied by patent ductus arteriosus. Herein, an 18-year-old woman with complex aortic coarctation and patent ductus arteriosus was successfully treated by endovascular thoracic stent graft via retroperitoneal approach. The reason for retroperitoneal iliac approach was small sized common femoral arteries which were not suitable for stent graft passage. This case is the first aortic coarctation plus patent ductus arteriosus case described in the literature which is treated by endovascular thoracic stent graft via retroperitoneal approach.

  16. Percutaneous implantation of thoracic and abdominal aortic prostheses in patients at high surgical risk

    Directory of Open Access Journals (Sweden)

    Juan C Ortiz

    2013-02-01

    intraluminal stent implantation is an alternative. Objective: to analyze the impact of percutaneous implantation of aortic stents in high-risk surgical patients with a minimum of one y ear follow-up. Method: Descriptive study conducted from December 2005 to March 2010 which included 125 patients with thoracic or abdominal aortic aneurysm, meeting surgical criteria by its diameter and that were rejected from surgery due to their high risk. The outcomes were intraoperative death from any cause and aneurysm-related at one, six and twelve months. Complications were defined as vascular occurred during the first thirty days. Results: Abdominal aneurysm was more frequent (70.4%. The overall mortality at 25.7 months follow-up was 14.8%. Of this percentage, 5.2% died from causes related to the aneurysm. One patient died during surgery. 4.3% were reoperated for leaks. There was higher aneurysm-related mortality in the thoracic (14.7 vs. 1.2% p = 0.003 and a trend in those of larger diameter (6.9 vs. 5.7 cm p = 0.210. There was no association between mortality and diabetes mellitus, smoking, heart disease, hypertension or dyslipidemia. Conclusions: aneurysm-related mortality in patients undergoing aortic stent graft is low. Mortality was associated with thoracic aneurysm and to its greater diameter. Complications did not imply an increase in mortality. In conclusion, in patients with aortic aneurysm and high surgical risk rejected for open surgery, percutaneous approach is a safe and effective treatment in a medium-term follow-up.

  17. Surgery for acute Type I aortic dissection without resection of supra-aortic entry sites leads to unfavourable aortic remodelling.

    Science.gov (United States)

    Heo, Woon; Song, Suk-Won; Lee, Kwang-Hun; Lee, Shin-Young; Kim, Tae-Hoon; Baek, Min-Young; Yoo, Kyung-Jong

    2018-01-29

    This study aimed to evaluate the impact of remnant re-entries in arch branches on postoperative change in the aortic arch and descending aortic diameters and the rate of major adverse aortic events. Between January 2010 and December 2016, 249 patients underwent surgery for acute Type I aortic dissection. Patients who underwent total arch replacement, had Marfan syndrome or had intramural haematoma were excluded. Seventy-two patients with predischarge and follow-up computed tomography scans were enrolled. Patients with and without re-entries in the arch branches after surgery were assigned to the supra-aortic entry (SAE, n = 21) and no supra-aortic entry (n = 51) groups, respectively. Diameters were measured at 7 levels: the innominate artery, left common carotid artery, left subclavian artery, 20 mm distal to the left subclavian artery, pulmonary artery bifurcation, coeliac axis and maximal diameter of the descending thoracic aorta. Growth rates at the levels of the pulmonary artery bifurcation and 20 mm distal to the left subclavian artery were significantly higher in the SAE group than in the no supra-aortic entry group. The rate of freedom from major adverse aortic events (annual growth >5 mm or maximal diameter of the descending thoracic aorta >50 mm) at 5 years was significantly higher in the no supra-aortic entry group than in the SAE group. Remnant SAE leads to unfavourable aortic remodelling after acute Type I aortic dissection repair. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. Multidetector-row computed tomography of thoracic aortic anomalies in dogs and cats: Patent ductus arteriosus and vascular rings

    Directory of Open Access Journals (Sweden)

    Nolte Ingo

    2011-09-01

    Full Text Available Abstract Background Diagnosis of extracardiac intrathoracic vascular anomalies is of clinical importance, but remains challenging. Traditional imaging modalities, such as radiography, echocardiography, and angiography, are inherently limited by the difficulties of a 2-dimensional approach to a 3-dimensional object. We postulated that accurate characterization of malformations of the aorta would benefit from 3-dimensional assessment. Therefore, multidetector-row computed tomography (MDCT was chosen as a 3-dimensional, new, and noninvasive imaging technique. The purpose of this study was to evaluate patients with 2 common diseases of the intrathoracic aorta, either patent ductus arteriosus or vascular ring anomaly, by contrast-enhanced 64-row computed tomography. Results Electrocardiography (ECG-gated and thoracic nongated MDCT images were reviewed in identified cases of either a patent ductus arteriosus or vascular ring anomaly. Ductal size and morphology were determined in 6 dogs that underwent ECG-gated MDCT. Vascular ring anomalies were characterized in 7 dogs and 3 cats by ECG-gated MDCT or by a nongated thoracic standard protocol. Cardiac ECG-gated MDCT clearly displayed the morphology, length, and caliber of the patent ductus arteriosus in 6 affected dogs. Persistent right aortic arch was identified in 10 animals, 8 of which showed a coexisting aberrant left subclavian artery. A mild dilation of the proximal portion of the aberrant subclavian artery near its origin of the aorta was present in 4 dogs, and a diverticulum analogous to the human Kommerell's diverticulum was present in 2 cats. Conclusions Contrast-enhanced MDCT imaging of thoracic anomalies gives valuable information about the exact aortic arch configuration. Furthermore, MDCT was able to characterize the vascular branching patterns in dogs and cats with a persistent right aortic arch and the morphology and size of the patent ductus arteriosus in affected dogs. This additional

  19. The repair of a type Ia endoleak following thoracic endovascular aortic repair using a stented elephant trunk procedure.

    Science.gov (United States)

    Qi, Rui-Dong; Zhu, Jun-Ming; Liu, Yong-Min; Chen, Lei; Li, Cheng-Nan; Xing, Xiao-Yan; Sun, Li-Zhong

    2018-04-01

    Type Ia endoleaks are not uncommon complications that occur after thoracic endovascular aortic repair (TEVAR). Because aortic arch vessels prevent extension of the landing zone, it is very difficult to manipulate a type Ia endoleak using an extension cuff or stent-graft, especially when the aortic arch is involved. Here, we retrospectively review our experience of surgical treatment of type Ia endoleak after TEVAR using a stented elephant trunk procedure. From July 2010 to August 2016, we treated 17 patients diagnosed with a type Ia endoleak following TEVAR using stented elephant trunk procedure. The mean age of our patients was 52 ± 8 years. The mean interval between TEVAR and the open surgical repair was 38 ± 43 months. All cases of type Ia endoleak (100%) were repaired successfully. There were no in-hospital deaths. One case required reintubation and continuous renal replacement therapy due to renal failure; this patient recovered smoothly before discharge. One other patient suffered a stroke and renal failure and did not fully recover following discharge, or follow-up. During follow-up, there were 3 deaths. Acceptable results were obtained using a stented elephant trunk procedure in patients with a type Ia endoleak after TEVAR. This technique allowed us to repair the proximal aortic arch lesions, surgically correct the type Ia endoleak, and promote false lumen thrombosis in the distal aorta. Implantation of a stented elephant trunk, with or without a concomitant aortic arch procedure, is an alternative approach for this type of lesion. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  20. Sparing of descending axons rescues interneuron plasticity in the lumbar cord to allow adaptive learning after thoracic spinal cord injury

    Directory of Open Access Journals (Sweden)

    Christopher Nelson Hansen

    2016-03-01

    Full Text Available This study evaluated the role of spared axons on structural and behavioral neuroplasticity in the lumbar enlargement after a thoracic spinal cord injury (SCI. Previous work has demonstrated that recovery in the presence of spared axons after an incomplete lesion increases behavioral output after a subsequent complete spinal cord transection (TX. This suggests that spared axons direct adaptive changes in below-level neuronal networks of the lumbar cord. In response to spared fibers, we postulate that lumbar neuron networks support behavioral gains by preventing aberrant plasticity. As such, the present study measured histological and functional changes in the isolated lumbar cord after complete TX or incomplete contusion (SCI. To measure functional plasticity in the lumbar cord, we used an established instrumental learning paradigm. In this paradigm, neural circuits within isolated lumbar segments demonstrate learning by an increase in flexion duration that reduces exposure to a noxious leg shock. We employed this model using a proof-of-principle design to evaluate the role of sparing on lumbar learning and plasticity early (7 days or late (42 days after midthoracic SCI in a rodent model. Early after SCI or TX at 7d, spinal learning was unattainable regardless of whether the animal recovered with or without axonal substrate. Failed learning occurred alongside measures of cell soma atrophy and aberrant dendritic spine expression within interneuron populations responsible for sensorimotor integration and learning. Alternatively, exposure of the lumbar cord to a small amount of spared axons for 6 weeks produced near-normal learning late after SCI. This coincided with greater cell soma volume and fewer aberrant dendritic spines on interneurons. Thus, an opportunity to influence activity-based learning in locomotor networks depends on spared axons limiting maladaptive plasticity. Together, this work identifies a time dependent interaction between

  1. Wall Shear Stress Estimation of Thoracic Aortic Aneurysm Using Computational Fluid Dynamics

    Directory of Open Access Journals (Sweden)

    J. Febina

    2018-01-01

    Full Text Available An attempt has been made to evaluate the effects of wall shear stress (WSS on thoracic aortic aneurysm (TAA using Computational Fluid Dynamics (CFD. Aneurysm is an excessive localized swelling of the arterial wall due to many physiological factors and it may rupture causing shock or sudden death. The existing imaging modalities such as MRI and CT assist in the visualization of anomalies in internal organs. However, the expected dynamic behaviour of arterial bulge under stressed condition can only be effectively evaluated through mathematical modelling. In this work, a 3D aneurysm model is reconstructed from the CT scan slices and eventually the model is imported to Star CCM+ (Siemens, USA for intensive CFD analysis. The domain is discretized using polyhedral mesh with prism layers to capture the weakening boundary more accurately. When there is flow reversal in TAA as seen in the velocity vector plot, there is a chance of cell damage causing clots. This is because of the shear created in the system due to the flow pattern. It is observed from the proposed mathematical modelling that the deteriorating WSS is an indicator for possible rupture and its value oscillates over a cardiac cycle as well as over different stress conditions. In this model, the vortex formation pattern and flow reversals are also captured. The non-Newtonian model, including a pulsatile flow instead of a steady average flow, does not overpredict the WSS (15.29 Pa compared to 16 Pa for the Newtonian model. Although in a cycle the flow behaviour is laminar-turbulent-laminar (LTL, utilizing the non-Newtonian model along with LTL model also overpredicted the WSS with a value of 20.1 Pa. The numerical study presented here provides good insight of TAA using a systematic approach to numerical modelling and analysis.

  2. Expression of platelet-derived growth factor B is upregulated in patients with thoracic aortic dissection.

    Science.gov (United States)

    Meng, Weixin; Liu, Shangdian; Li, Dandan; Liu, Zonghong; Yang, Hui; Sun, Bo; Liu, Hongyu

    2018-04-20

    Thoracic aortic dissection (TAD) is a serious condition requiring urgent treatment to avoid catastrophic consequences. The inflammatory response is involved in the occurrence and development of TAD, possibly potentiated by platelet-derived growth factors (PDGFs). This study aimed to determine whether expression of PDGF-B (a subunit of PDGF-BB) was increased in TAD patients and to explore the factors responsible for its upregulation and subsequent effects on TAD. Full-thickness ascending aorta wall specimens from TAD patients (n = 15) and control patients (n = 10) were examined for expression of PDGF-B and its receptor (PDGFRB) and in terms of morphology, inflammation, and fibrosis. Blood samples from TAD and control patients were collected to detect plasma levels of PDGF-BB and soluble elastins. Expression levels of PDGF-B, PDGFRB, and collagen I were significantly enhanced in ascending aorta wall specimens from TAD patients compared with controls. Furthermore, soluble elastic fragments and PDGF-BB were significantly increased in plasma from TAD patients compared with controls, and numerous irregular elastic fibers and macrophages were seen in the ascending aorta wall in TAD patients. An increase in elastic fragments in the aorta wall might be responsible for inducing the activation and migration of macrophages to injured sites, leading to elevated expression of PDGF-B, which in turn induces deposition of collagen, disrupts extracellular matrix homeostasis, and increases the stiffness of the aorta wall, resulting in compromised aorta compliance. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  3. Traumatic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Brianna Miner

    2016-09-01

    Full Text Available History of present illness: A 48-year-old male with unknown past medical history presents as a trauma after being hit by a car traveling approximately 25 miles per hour. On initial presentation, the patient is confused, combative, and not answering questions appropriately. The patient is hypotensive with a blood pressure of 68/40 and a heart rate of 50 beats per minute, with oxygen saturation at 96% on room air. FAST scan is positive for fluid in Morrison’s pouch, splenorenal space, and pericardial space. Significant findings: The initial chest x-ray showed an abnormal superior mediastinal contour (blue line, suggestive of a possible aortic injury. The CT angiogram showed extensive circumferential irregularity and outpouching of the distal aortic arch (red arrows compatible with aortic transection. In addition, there was a circumferential intramural hematoma, which extended through the descending aorta to the proximal infrarenal abdominal aorta (green arrow. There was also an extensive surrounding mediastinal hematoma extending around the descending aorta and supraaortic branches (purple arrows. Discussion: Traumatic aortic injury is a life-threatening event. The incidence of blunt thoracic aortic injury is low, between 1 to 2 percent of those patients with blunt thoracic trauma.1 However, approximately 80% of patients with traumatic aortic injury die at the scene.2 Therefore it is imperative to diagnose traumatic aortic injury in a timely fashion. The diagnosis can be difficult due to the non-specific signs and symptoms and other distracting injuries. Clinical suspicion should be based on the mechanism of the injury and the hemodynamic status of the patient. In any patient with blunt or penetrating trauma to the chest that is hemodynamically unstable, traumatic aortic injury should be on the differential. Chest x-ray can be used as a screening tool. A normal chest x-ray has a negative predictive value of approximately 97%. CTA chest is the

  4. Anomalous Origin of the Right Coronary Artery from the Left Anterior Descending Coronary Artery in a Patient with Ascending Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    Ufuk Gürkan

    2012-04-01

    Full Text Available The incidence of coronary artery anomalies has been reported between 0.6 to 1.3% in angiographic series and 0.3% in autopsy series. An isolated single coronary artery (SCA is even a rarer congenital anomaly occurring in approximately 0.02% of the population. The ectopic origin of the right coronary artery (RCA from the left anterior descending (LAD artery is relatively rare and more benign than other types of anomalous origin of the RCAs. We report a case of an adult male patient with SCA anomaly in which the RCA takes off from the mid LAD. To the best of our knowledge, SCA anomaly coinciding with ascending aortic aneurysm which was treated with Bentall operation has never been described before.

  5. Society of Thoracic Surgeons Risk Score Predicts Hospital Charges and Resource Utilization After Aortic Valve Replacement

    Science.gov (United States)

    Arnaoutakis, George J.; George, Timothy J.; Alejo, Diane E.; Merlo, Christian A.; Baumgartner, William A.; Cameron, Duke E.; Shah, Ashish S.

    2011-01-01

    Context The impact of Society of Thoracic Surgeons (STS) predicted mortality risk score on resource utilization after aortic valve replacement (AVR) has not been previously studied. Objective We hypothesize that increasing STS risk scores in patients having AVR are associated with greater hospital charges. Design, Setting, and Patients Clinical and financial data for patients undergoing AVR at a tertiary care, university hospital over a ten-year period (1/2000–12/2009) were retrospectively reviewed. The current STS formula (v2.61) for in-hospital mortality was used for all patients. After stratification into risk quartiles (Q), index admission hospital charges were compared across risk strata with Rank-Sum tests. Linear regression and Spearman’s coefficient assessed correlation and goodness of fit. Multivariable analysis assessed relative contributions of individual variables on overall charges. Main Outcome Measures Inflation-adjusted index hospitalization total charges Results 553 patients had AVR during the study period. Average predicted mortality was 2.9% (±3.4) and actual mortality was 3.4% for AVR. Median charges were greater in the upper Q of AVR patients [Q1–3,$39,949 (IQR32,708–51,323) vs Q4,$62,301 (IQR45,952–97,103), p=<0.01]. On univariate linear regression, there was a positive correlation between STS risk score and log-transformed charges (coefficient: 0.06, 95%CI 0.05–0.07, p<0.01). Spearman’s correlation R-value was 0.51. This positive correlation persisted in risk-adjusted multivariable linear regression. Each 1% increase in STS risk score was associated with an added $3,000 in hospital charges. Conclusions This study showed increasing STS risk score predicts greater charges after AVR. As competing therapies such as percutaneous valve replacement emerge to treat high risk patients, these results serve as a benchmark to compare resource utilization. PMID:21497834

  6. Hybrid Repair of Complex Thoracic Aortic Arch Pathology: Long-Term Outcomes of Extra-anatomic Bypass Grafting of the Supra-aortic Trunk

    International Nuclear Information System (INIS)

    Lotfi, S.; Clough, R. E.; Ali, T.; Salter, R.; Young, C. P.; Bell, R.; Modarai, B.; Taylor, P.

    2013-01-01

    Hybrid repair constitutes supra-aortic debranching before thoracic endovascular aortic repair (TEVAR). It offers improved short-term outcome compared with open surgery; however, longer-term studies are required to assess patient outcomes and patency of the extra-anatomic bypass grafts. A prospectively maintained database of 380 elective and urgent patients who had undergone TEVAR (1997–2011) was analyzed retrospectively. Fifty-one patients (34 males; 17 females) underwent hybrid repair. Median age was 71 (range, 18–90) years with mean follow-up of 15 (range, 0–61) months. Perioperative complications included death: 10 % (5/51), stroke: 12 % (6/51), paraplegia: 6 % (3/51), endoleak: 16 % (8/51), rupture: 4 % (2/51), upper-limb ischemia: 2 % (1/51), bypass graft occlusion: 4 % (2/51), and cardiopulmonary complications in 14 % (7/51). Three patients (6 %) required emergency intervention for retrograde dissection: (2 aortic root repairs; 2 innominate stents). Early reintervention was performed for type 1 endoleak in two patients (2 proximal cuff extensions). One patient underwent innominate stenting and revision of their bypass for symptomatic restenosis. At 48 months, survival was 73 %. Endoleak was detected in three (6 %) patients (type 1 = 2; type 2 = 1) requiring debranching with proximal stent graft (n = 2) and proximal extension cuff (n = 1). One patient had a fatal rupture of a mycotic aneurysm and two arch aneurysms expanded. No bypass graft occluded after the perioperative period. Hybrid operations to treat aortic arch disease can be performed with results comparable to open surgery. The longer-term outcomes demonstrate low rates of reintervention and high rates of graft patency.

  7. Hybrid Repair of Complex Thoracic Aortic Arch Pathology: Long-Term Outcomes of Extra-anatomic Bypass Grafting of the Supra-aortic Trunk

    Energy Technology Data Exchange (ETDEWEB)

    Lotfi, S., E-mail: shamim.lotfi@kcl.ac.uk; Clough, R. E.; Ali, T. [Guy' s and St. Thomas' NHS Trust, Vascular Surgery (United Kingdom); Salter, R. [Guy' s and St. Thomas' NHS Trust, Interventional Radiology (United Kingdom); Young, C. P. [Guy' s and St. Thomas' NHS Trust, Cardiac Surgery (United Kingdom); Bell, R.; Modarai, B.; Taylor, P., E-mail: peter.taylor@gstt.nhs.uk [Guy' s and St. Thomas' NHS Trust, Vascular Surgery (United Kingdom)

    2013-02-15

    Hybrid repair constitutes supra-aortic debranching before thoracic endovascular aortic repair (TEVAR). It offers improved short-term outcome compared with open surgery; however, longer-term studies are required to assess patient outcomes and patency of the extra-anatomic bypass grafts. A prospectively maintained database of 380 elective and urgent patients who had undergone TEVAR (1997-2011) was analyzed retrospectively. Fifty-one patients (34 males; 17 females) underwent hybrid repair. Median age was 71 (range, 18-90) years with mean follow-up of 15 (range, 0-61) months. Perioperative complications included death: 10 % (5/51), stroke: 12 % (6/51), paraplegia: 6 % (3/51), endoleak: 16 % (8/51), rupture: 4 % (2/51), upper-limb ischemia: 2 % (1/51), bypass graft occlusion: 4 % (2/51), and cardiopulmonary complications in 14 % (7/51). Three patients (6 %) required emergency intervention for retrograde dissection: (2 aortic root repairs; 2 innominate stents). Early reintervention was performed for type 1 endoleak in two patients (2 proximal cuff extensions). One patient underwent innominate stenting and revision of their bypass for symptomatic restenosis. At 48 months, survival was 73 %. Endoleak was detected in three (6 %) patients (type 1 = 2; type 2 = 1) requiring debranching with proximal stent graft (n = 2) and proximal extension cuff (n = 1). One patient had a fatal rupture of a mycotic aneurysm and two arch aneurysms expanded. No bypass graft occluded after the perioperative period. Hybrid operations to treat aortic arch disease can be performed with results comparable to open surgery. The longer-term outcomes demonstrate low rates of reintervention and high rates of graft patency.

  8. Thoracic aortic injury in motor vehicle crashes: the effect of impact direction, side of body struck, and seat belt use.

    Science.gov (United States)

    Fitzharris, Michael; Franklyn, Melanie; Frampton, Richard; Yang, King; Morris, Andrew; Fildes, Brian

    2004-09-01

    Using in-depth, real-world motor vehicle crash data from the United States and the United Kingdom, we aimed to assess the incidence and risk factors associated with thoracic aorta injuries. De-identified National Automotive Sampling System Crashworthiness Data System (U.S.) and Co-operative Crash Injury Study (U.K.) data formed the basis of this retrospective analysis. Logistic regression was used to assess the level of risk of thoracic aorta injury associated with impact direction, seat belt use and, given the asymmetry of the thoracic cavity, whether being struck toward the left side of the body was associated with increased risk in side-impact crashes. A total of 13,436 U.S. and 3,756 U.K. drivers and front seat passengers were analyzed. The incidence of thoracic aorta injury in the U.S. and U.K. samples was 1.5% (n = 197) and 1.9% (n = 70), respectively. The risk was higher for occupants seated on the side closest to the impact than for occupants involved in frontal impact crashes. This was the case irrespective of whether the force was applied toward the left (belted: relative risk [RR], 4.6; 95% confidence interval [CI], 2.9-7.1; p direction. Thoracic aorta injuries were found to be associated with high impact severity, and being struck by a sports utility vehicle relative to a passenger vehicle (RR, 1.7; 95% CI, 1.2-2.3; p = 0.001). Aortic injuries have been conventionally associated with frontal impacts. However, emergency clinicians should be aware that occupants of side-impact crashes are at greater risk, particularly if the occupant was unbelted and involved in a crash of high impact severity.

  9. Commentary on “Inhibition of interleukin-1beta decreases aneurysm formation and progression in a novel model of thoracic aortic aneurysms”

    Directory of Open Access Journals (Sweden)

    Yonghua Bi

    2015-09-01

    Full Text Available Aortic aneurysm is a silent but life-threatening disease, whose pathogenesis remains poorly understood. Aneurysm models have been induced in small animals to study its pathogenesis, Johnston WF et al. successfully induced a novel model of thoracic aortic aneurysms (TAA by periadventitial application of elastase in mice. We comment on this model according to our experiment. We hypothesize that endogenous MMPs, especially MMP2, play a vital role in complex repair process of aneurysmal wall, which should be a key target in the investigation and treatment of aortic aneurysms.

  10. Surgical treatment and thoracic endovascular aortic repair in type A aortic dissection in a pregnant patient with Marfan syndrome.

    Science.gov (United States)

    Sterner, Doerthe; Probst, Chris; Mellert, Friedrich; Schiller, Wolfgang

    2014-07-01

    We report an acute aortic dissection type Stanford A extending down to both iliac arteries affecting a 32-year-old woman suspected to have Marfan syndrome during week 37 of pregnancy. In a multidisciplinary approach, and emergency Cesarean section was performed followed by an abdominal hysterectomy and a valve-sparing aortic root replacement using a reimplantation technique. The aorta was replaced up to the hemi arch. Because of the high suspicion of visceral ischemia as confirmed ex juvantibus, an endovascular stent graft was implanted. Molecular testing revealed a frameshift mutation and confirmed the diagnosis of Marfan syndrome. Both the patient and her healthy child underwent an uneventful recovery. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Thoracic and abdominal aortic diameters in a general population: MRI-based reference values and association with age and cardiovascular risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Mensel, Birger; Hesselbarth, Lydia; Wenzel, Michael; Kuehn, Jens-Peter; Hegenscheid, Katrin [University Medicine Greifswald, Institute of Diagnostic Radiology and Neuroradiology, Greifswald (Germany); Doerr, Marcus [University Medicine Greifswald, Department of Internal Medicine, Greifswald (Germany); DZHK (German Center for Cardiovascular Research), partner site Greifswald, Greifswald (Germany); Voelzke, Henry [University Medicine Greifswald, Institute for Community Medicine, Greifswald (Germany); DZHK (German Center for Cardiovascular Research), partner site Greifswald, Greifswald (Germany); Lieb, Wolfgang [Christian Albrechts University, Institute of Epidemiology, Kiel (Germany); Lorbeer, Roberto [Ludwig-Maximilians-University Hospital, Institute of Clinical Radiology, Munich (Germany)

    2016-04-15

    To generate reference values for thoracic and abdominal aortic diameters determined by magnetic resonance imaging (MRI) and analyse their association with cardiovascular risk factors in the general population. Data from participants (n = 1759) of the Study of Health in Pomerania were used for analysis in this study. MRI measurement of thoracic and abdominal aortic diameters was performed. Parameters for calculation of reference values according to age and sex analysis were provided. Multivariable linear regression models were used for determination of aortic diameter-related risk factors, including smoking, blood pressure (BP), high-density lipoprotein cholesterol (HDL-C). For the ascending aorta (β = -0.049, p < 0.001), the aortic arch (β = -0.061, p < 0.001) and the subphrenic aorta (β = -0.018, p = 0.004), the body surface area (BSA)-adjusted diameters were lower in men. Multivariable-adjusted models revealed significant increases in BSA-adjusted diameters with age for all six aortic segments (p < 0.001). Consistent results for all segments were observed for the positive associations of diastolic BP (β = 0.001; 0.004) and HDL (β = 0.035; 0.087) with BSA-adjusted aortic diameters and for an inverse association of systolic BP (β = -0.001). Some BSA-adjusted median aortic diameters are smaller in men than in women. All diameters increase with age, diastolic blood pressure and HDL-C and decrease as systolic BP increases. (orig.)

  12. Surgical treatment of penetrating atherosclerotic ulcer of the descending aorta

    Directory of Open Access Journals (Sweden)

    Kovačević Pavle

    2013-01-01

    Full Text Available Introduction. The term “penetrating atherosclerotic ulcer” (PAU of the aorta describes the condition in which ulceration of an aortic atherosclerotic lesion penetrates the internal elastic lamina into media. PAU is a high-risk lesion due to its deleterious effects on the integrity of aortic wall, with potentially fatal outcome. Case report. A patient with intensive, sharp chest pain irradiating to the back but with no signs of myocardial ischemia on an electrocardiogram was referred to our hospital. Transthoracic echocardiography showed no pathological changes of the ascending aorta. However, multislice computed tomography (CT showed an aortic ulcer with varying degree of the subadventitial hemorrhage in the region of the thoracic aorta at the level of Th 8-9. Due to imminent rupture of the penetrating aortic ulcer, the patient was promptly prepared for surgery. A 15 cm long subadventitial hematoma was found intraoperatively in the right posterolateral aspect of the descending aorta, 5 cm above the diaphragm and 7 cm below the origin of the left subclavial artery. The affected segment of the aorta was resected, followed by an inlay aortic reconstruction with a Dacron tube graft of 24 mm. Control CT revealed satisfactory reconstruction of the descending aorta. Conclusion. PAU is a rare, but potentially fatal disease. Open surgery in patients with PAU is an effective treatment strategy, although endovascular treatment options are emerging.

  13. Interleukin-6 downregulated vascular smooth muscle cell contractile proteins via ATG4B-mediated autophagy in thoracic aortic dissection.

    Science.gov (United States)

    An, Zhao; Qiao, Fan; Lu, Qijue; Ma, Ye; Liu, Yang; Lu, Fanglin; Xu, Zhiyun

    2017-12-01

    Interleukin-6 (IL-6) overexpression played an important role in the pathogenesis of thoracic aortic dissection (TAD). Our previous study found enhanced autophagy accompanying with contractile proteins α smooth muscle actin (α-SMA) and smooth muscle 22α (SM22α) degradation in TAD aortic vascular smooth muscle cells (VSMCs). Autophagy is an important way for intracellular proteins degradation, while IL-6 has been found as a contributing factor of autophagy in some cancers. These indicated IL-6 might contribute to the occurrence of TAD by promoting autophagy-induced contractile proteins degradation, which has not been investigated. The aim of the present study is to verify this hypothesis and investigate the mechanism of it. We collected 10 TAD and 10 control aortic specimens from patients underwent TAD surgical repair and coronary artery bypass grafting, respectively. Quantitative real-time polymerase chain reaction was used to detect mRNA expression. Protein expression level was assessed by enzyme-linked immunosorbent assay, western blot, and immunohistochemistry. Microtubule-associated protein 1 light chain 3 beta overexpression adenovirus with green and red fluorescent protein tags and transmission electron microscopy were used to detect autophagy level in VSMCs. 3-Methyladenine (3-MA) and chloroquine were used to block autophagy in human VSMCs. Experiment results showed that the expression of IL-6 was significantly increased accompanying with up-regulated autophagy in TAD aortic wall compared with controls. In vitro results showed that IL-6 stimulation decreased the expression of VSMCs contractile proteins α-SMA and SM22α accompanying with up-regulated autophagy. Blocking autophagy with 3-MA or chloroquine inhibited IL-6 induced α-SMA and SM22α degradation. Further investigation showed that autophagy-related 4B cysteine peptidase (ATG4B) was significantly overexpressed in TAD aortic wall and played important role in IL-6 induced autophagy up

  14. Thoracic aortic stent-graft placement combined with left subclavian artery 'chimney operation': therapeutic analysis of 15 cases with insufficient proximal anchor area

    International Nuclear Information System (INIS)

    Liu Jiayi; Huang Lianjun; Fan Zhanming; Zhang Zhaoqi

    2012-01-01

    Objective: To discuss the strategies for the management of insufficient proximal anchoring area during the performance of transluminal stent-graft placement (TSGP), and to evaluate the feasibility of intentional coverage of the left subclavian artery (LSA) together with left subclavian artery stent-graft placement by using 'chimney operation' technique. Methods: A total of 15 patients with thoracic aortic diseases complicated by insufficient proximal anchoring area, who were encountered in authors' hospital during the period from Dec. 2009 to April 2011, were enrolled in this study. The clinical data were retrospectively analyzed. The thoracic aortic diseases included aortic dissection (n=6), aortic pseudoaneurysm (n=1), aortic aneurysm (n=4) and penetrating ulcer (n=4). Of the 15 patients, the distance between the lesion and LSA anchoring site 15 mm in 2. TSGP was carried out. The ostium of LSA was intentionally and completely covered by thoracic aortic stent-graft and left subclavian artery stent-graft placement was subsequently performed. The patients were kept under observation for symptoms of cerebral and upper limb ischemia. The postoperative complications such as endoleak and the patency of LSA were assessed with angiography. Results: Thoracic aortic stent-graft placement was successfully carried out in all 15 patients. In addition, one 'chimney' stent was properly implanted in LSA in each patient. After the procedure, no complications of nervous system or severe ischemia of upper extremity occurred. Follow-up examinations performed between 5 days to 3 months after the treatment revealed that the aortic stent-graft remained in stable condition and no type Ⅰ endoleak occurred, meanwhile the blood flow in 'chimney' stent was unobstructed. Conclusion: Intentional LSA coverage with 'chimney operation' can expand the applicability of TSGP with high tolerability. It is especially useful for patients with left vertebral artery blood supply dominance or with

  15. Aortic root repair for thoracic aorta false aneurysm following Bentall procedure.

    Science.gov (United States)

    Kumar, Sanjay; Jones, Steve; Sivananthan, U M; McGoldrick, J P

    2008-08-01

    The Bentall procedure for aortic root replacement in Marfan's syndrome is safe and durable. We describe successful repair of periprosthetic valvular leak, 12 years following Bentall repair with composite graft. The aim of this report is to analyse and evaluate technical factors leading to this unusual occurrence.

  16. Intravascular ultrasound is a critical tool for accurate endograft sizing in the management of blunt thoracic aortic injury.

    Science.gov (United States)

    Wallace, Gabriel A; Starnes, Benjamin W; Hatsukami, Thomas S; Sobel, Michael; Singh, Niten; Tran, Nam T

    2015-03-01

    Accurate measurement of true aortic luminal diameter (ALD) is critical for endograft sizing in endovascular treatment of blunt thoracic aortic injury (BTAI), but ALD is dynamic and changes with respect to patients' hemodynamic status. This study aimed to characterize how ALD at the time of diagnosis of BTAI compares with ALD at the time of endovascular repair and later at follow-up. This is an Institutional Review Board-approved, single-institution retrospective analysis of prospectively obtained data. Patients were included who presented between July 2007 and December 2012 with computed tomography angiography (CTA)-diagnosed BTAI; who underwent thoracic endovascular aortic repair (TEVAR); and who underwent preoperative CTA, intraoperative intravascular ultrasound (IVUS), and postimplantation CTA. Comparison measurements of the ALD were made among CTA and IVUS images at the level of the left subclavian artery (LSCA) and between initial CTA and postimplantation CTA at 10, 15, and 20 cm distal to the LSCA. Theoretical endograft sizes were determined and compared for each ALD at the LSCA. Twenty-two patients were included in the analysis. Mean age was 38 ± 14 years (range, 17-61 years), with 82% men and mean Injury Severity Score of 43 ± 11 (range, 24-66). Mean time from emergency department admission to initial CTA was -1.2 ± 5 hours (range, -13 to 11.5 hours; negative time implies imaging at an outside facility before admission). Mean time from initial CTA to IVUS was 1.2 ± 1.4 days (range, 2.5 hours-5.7 days) and from IVUS to postimplantation CTA 33 ± 45 days (range, 17 hours-169 days). Overall, ALD measured by IVUS was significantly larger than that by initial CTA (Δ2.5 ± 3.1 mm; P < .05). ALD was also larger at 10, 15, and 20 cm distal to the LSCA in comparing the postimplantation CTA with the initial CTA (Δ2.4, 2.0, and 2.0 mm, respectively; all P < .05). More than half the devices would be sized differently with ALD measured by IVUS at the time of TEVAR

  17. Type 1a endoleak following Zone 1 and Zone 2 thoracic endovascular aortic repair: effect of bird-beak configuration.

    Science.gov (United States)

    Kudo, Tomoaki; Kuratani, Toru; Shimamura, Kazuo; Sakamoto, Tomohiko; Kin, Keiwa; Masada, Kenta; Shijo, Takayuki; Torikai, Kei; Maeda, Koichi; Sawa, Yoshiki

    2017-10-01

    Type 1a endoleak is one of the most severe complications after thoracic endovascular aortic repair (TEVAR), because it carries the risk of aortic rupture. The association between bird-beak configuration and Type 1a endoleak remains unclear. The purpose of this study was to analyse the predictors of Type 1a endoleak following Zone 1 and Zone 2 TEVAR, with a particular focus on the effect of bird-beak configuration. From April 2008 to July 2015, 105 patients (mean age 68.6 years) who underwent Zone 1 and 2 landing TEVAR were enrolled, with a mean follow-up period of 4.3 years. The patients were categorized into 2 groups, according to the presence (Group B, n = 32) or the absence (Group N, n = 73) of bird-beak configuration on the first postoperative multidetector computed tomography. The Kaplan-Meier event-free rate curve showed that Type 1a endoleak and bird-beak progression occurred less frequently in Group N than in Group B. Five-year freedom from Type 1a endoleak rates were 79.7% and 100% for Groups B and N, respectively (P = 0.007). Multivariable logistic regression analysis showed that dissecting aortic aneurysm (odds ratio 3.72, 95% confidence interval 1.30-11.0; P = 0.014) and shorter radius of inner curvature (odds ratio 1.09, 95% confidence interval 0.85-0.99; P = 0.025) were significant risk factors for bird-beak configuration. Multivariable Cox proportional hazard regression showed that Z-type stent graft (hazard ratio 2.69, 95% confidence interval 1.11-6.51; P = 0.030) was a significant risk factor for bird-beak progression. Appropriate stent grafts need to be chosen carefully to prevent Type 1a endoleak and bird-beak configuration after landing Zone 1 and 2 TEVAR. Patients with bird-beak configuration on early postoperative multidetector computed tomography require closer follow-up to screen for Type 1a endoleak. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic

  18. Comparison of neurocognitive results after coronary artery bypass grafting and thoracic aortic surgery using retrograde cerebral perfusion.

    Science.gov (United States)

    Miyairi, Takeshi; Takamoto, Shinichi; Kotsuka, Yutaka; Takeuchi, Atsuko; Yamanaka, Katsuo; Sato, Hajime

    2005-07-01

    Retrograde cerebral perfusion (RCP) is used as an adjunctive method to hypothermic circulatory arrest to enhance cerebral protection in patients undergoing thoracic aortic surgery. It remains unclear whether RCP provides improved neurological and neuropsychological outcome. Forty-six patients undergoing thoracic aortic surgery using RCP, and 28 undergoing coronary artery bypass grafting (CABG; n = 28) with CPB, were enrolled in the study. Patients receiving RCP were subdivided into two groups, those with less than 60 min of RCP (S-RCP; n = 27) and with 60 min or more (L-RCP; n = 19). The patients' neurocognitive state was assessed by the revised Wechsler Adult Intelligence Scale a few days before operation, at 2-3 weeks and 4-6 months after operation. There were no stroke, seizure, and hospital mortality in either group. Significant decline between baseline and early scores were seen in three subtests (digit span, arithmetic, and picture completion) for S-RCP and four (digit span, arithmetic, picture completion, and picture arrangement) for L-RCP. Significant decline between baseline and late scores were seen in one subtest (arithmetic) for S-RCP, four (digit span, arithmetic, picture completion, and picture arrangement) for L-RCP, and one (object assembly) for CABG. The mean change of scores for one late test (digit symbol) was significantly lower in S-RCP than in CABG. The mean change of scores for three early tests (digit span, vocabulary, and picture arrangement) and four late tests (information, digit span, picture completion, and picture arrangement) were significantly lower in L-RCP than in CABG. Stepwise logistic regression analysis disclosed that, after considering the other variables, significant difference in test score changes were observed between CABG and L-RCP for two early tests (picture completion and digit symbol) as well as for three late tests (digit span, similarities, and picture completion). None of test score changes showed significant

  19. Proximal thoracic aorta dimensions after continuous-flow left ventricular assist device implantation: Longitudinal changes and relation to aortic valve insufficiency.

    Science.gov (United States)

    Fine, Nowell M; Park, Soon J; Stulak, John M; Topilsky, Yan; Daly, Richard C; Joyce, Lyle D; Pereira, Naveen L; Schirger, John A; Edwards, Brooks S; Lin, Grace; Kushwaha, Sudhir S

    2016-04-01

    In this study we examined the impact of continuous-flow left ventricular assist device (CF-LVAD) support on proximal thoracic aorta dimensions. Aortic root and ascending aorta diameter were measured from serial echocardiograms before and after CF-LVAD implantation in patients with ≥6 months of support, and correlated with the development of >mild aortic valve insufficiency (AI). Of 162 patients included, mean age was 58 ± 11 years and 128 (79%) were male. Seventy-nine (63%) were destination therapy patients. Mean aortic root and ascending aorta diameters at baseline, 1 month, 6 months, 12 months and long-term follow-up (mean 2.0 ± 1.4 years) were 3.5 ± 0.4, 3.5 ± 0.3, 3.9 ± 0.3, 3.9 ± 0.2 and 4.0 ± 0.3, and 3.3 ± 0.2, 3.3 ± 0.3, 3.6 ± 0.2, 3.6 ± 0.3 and 3.6 ± 0.3 cm, respectively. Only change in aortic root diameter from 1-month to 6-month follow-up reached statistical significance (p = 0.03). Nine (6%) patients had accelerated proximal thoracic aorta expansion (>0.5 cm/year), occurring predominantly in the first 6 months after implantation. These patients were older and more likely to have hypertension and baseline proximal thoracic aorta dilation. Forty-five (28%) patients developed >mild AI at long-term follow-up, including 7 of 9 (78%) of those with accelerated proximal thoracic aorta expansion. All 7 had aortic valves that remained closed throughout the cardiac cycle, and this, along with duration of CF-LVAD support and increase in aortic root diameter, were significantly associated with developing >mild AI. CF-LVAD patients have small increases in proximal thoracic aorta dimensions that predominantly occur within the first 6 months after implantation and then stabilize. Increasing aortic root diameter was associated with AI development. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  20. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    Energy Technology Data Exchange (ETDEWEB)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua [University Hospital, University of Cologne, Department of Radiology, Cologne (Germany); Pfister, Roman [University Hospital, University of Cologne, Department of Internal Medicine III, Cologne (Germany); Deppe, Antje-Christin [University Hospital, University of Cologne, Department of Cardiothoracic Surgery, Cologne (Germany); Matoussevitch, Vladimir [University Hospital, University of Cologne, Department of Vascular Surgery, Cologne (Germany)

    2014-06-15

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  1. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    International Nuclear Information System (INIS)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua; Pfister, Roman; Deppe, Antje-Christin; Matoussevitch, Vladimir

    2014-01-01

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  2. Aortic dissection. Basic aspects and endovascular management

    International Nuclear Information System (INIS)

    Jaramillo, Nicolas I; Alviar, Carlos I

    2005-01-01

    Treatment of thoracic aortic pathology is complicated by the morbidity associated to the surgical procedure and to the frailty of an elderly and difficult population. Surgical operation in this kind of population frequently bears a significant incidence of death and long-term disability. In an effort to reduce the incidence of negative outcomes, minimally invasive techniques in the form of endovascular stenting have been introduced during the past decade. The technology, originally described by Parodi, and initially designed for its use in abdominal aortic aneurysms, has been adapted for the treatment of thoracic aortic aneurysms. Furthermore, an improved understanding of the pathophysiology and the natural history of thoracic aortic disease as well as the analysis of the outcomes have facilitated our treatment decisions in terms of the timing for an appropriate intervention. Treatment of thoracic aortic dissection using endovascular Stent is one of the more recent advances in this condition and is receiving increasing attention, as it is a less invasive alternative to an open surgical repair. Although this technology is still innovative, significant improvements have been made lately in the design and deployment of the endovascular Stent-grafts. These prostheses have been increasingly used to treat aneurysms, dissections and traumatic ruptures, as well as giant penetrating ulcers and intramural hematomas of the descending thoracic aorta with good early and mid-term outcomes. The rareness, complexity and severity of the pathology and the theoretically high risk of complications should render the surgeon extremely cautious especially with young patients. Conceptually, the endo luminal treatment in the acute phase seems to be the solution and will probably become a preferred therapy while technical refinement is under way. Worldwide experience is growing and with this a better understanding of the indications and limitations of this innovative therapy will be

  3. Acute Type A Aortic Dissection Successfully Managed with One-stage Surgery of Total Aortic Arch Replacement with Supra-aortic Transposition Plus Frozen Elephant Trunk Technique

    Directory of Open Access Journals (Sweden)

    Meng-Lin Lee

    2014-09-01

    Full Text Available Acute type A aortic dissection has long been a challenging issue. The surgical techniques traditionally vary with the anatomic extent of the aortic dissection. Simple ascending aortic grafting can be lifesaving, but the lesions beyond the aorta, which include the arch vessels and descending aorta, remain potential hazards. In this paper, we present a patient in which acute type A aortic dissection with lesions extending into descending thoracic aorta was successfully managed by total arch replacement with supra-aortic transposition plus the frozen elephant trunk technique to the descending aorta. A 67-year-old gentleman presented with severe tearing pain from the anterior to posterior chest. Computed tomography confirmed the diagnosis of acute type A dissection extending to the level of the right common iliac artery. An emergent operation was performed as in the aforementioned technique. The surgery went well and the patient was discharged without comorbidities on postoperative day 25. The patient had regular outpatient clinical follow-up. The follow-up computed tomography images showed adequate results with the obliteration of the false lumen. In conclusion, total aortic arch replacement with supra-aortic transposition plus frozen elephant trunk technique is a safe and feasible operative method for patients with detrimental acute type A aortic dissection.

  4. Successful management of threatened aortic rupture late after rib fracture caused by blunt chest trauma.

    Science.gov (United States)

    Morimoto, Yoshihisa; Sugimoto, Takaki; Sakahira, Hideki; Matsuoka, Hidehito; Yoshioka, Yuki; Arase, Hiroki

    2014-05-01

    A 62-year-old man was crushed in a car accident and diagnosed with a fractured left ninth rib, pulmonary and heart contusion, hemopneumothorax, and descending aortic injury based on a computed tomography scan. He underwent chest tube drainage and was intubated for mechanical ventilation because a bone fragment of the ninth rib threatened to penetrate the descending aorta. On the second posttrauma day, computed tomography showed the bone fragment of the ninth rib approaching the descending aorta. He underwent graft replacement of the injured portion of the descending thoracic aorta, and we removed the fractured left ninth rib. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Retrograde type A dissection: a serious complication due to thoracic aortic endovascular stent-graft repair for Stanford type B aortic dissection

    International Nuclear Information System (INIS)

    Wang Guoquan; Zhai Shuiting; Li Tianxiao; Shi Shuaitao; Zhang Kewei; Li Kun

    2011-01-01

    Objective: to discuss the possible causes and prevention of retrograde type A dissection occurred after thoracic aortic endovascular stent-graft repair (TEVAR) for symptomatic type B dissection. Methods: During the period from January 2005 to January 2011, TEVAR was carried out in 189 patients (157 males and 32 females) with symptomatic type B dissection. The average age of the patients was (51.2±13.5) years, ranged from 26 to 78 years. A follow-up lasting for 3-63 months (mean 32 months) was conducted in 135 patients (71.43%). Fifty-four patients lost in touch with the authors (28.57%). The occurrence of retrograde type A dissection after TEVAR was calculated and the possible causes were analyzed. Results: After TEVAR retrograde type A dissection occurred in two patients (1.48%), and both were males. One patient developed retrograde type A dissection in perioperative period, and the patient refused to have surgery. Conservative treatment was employed for over three years and be was still alive so far. The other patient developed retrograde type A dissection one month after TEVAR, and emergency surgery was performed. The patient was followed up for three months and he was still alive. Conclusion: The retrograde type A dissection occurred after TEVAR may be closely related to the stent-graft device, to the interventional manipulations and to the vascular disorders. Close attention should be paid to the direct damage produced by the stent-graft device to the vascular wall. (authors)

  6. Case report and review of the literature total endovascular repair of acute ascending aortic rupture: a case report and review of the literature.

    Science.gov (United States)

    McCallum, John C; Limmer, Karl K; Perricone, Anthony; Bandyk, Dennis; Kansal, Nikhil

    2013-07-01

    Thoracic aortic endografting has been successfully implemented to treat aneurysmal disease of the distal aortic arch and descending thoracic aorta. Although there are reports of ascending aortic endovascular interventions, the total endovascular repair of a ruptured ascending aorta secondary to a Type A dissection has not been described. We report the case of a 77-year-old patient who presented with a ruptured ascending aortic aneurysm secondary to degeneration of a Stanford type A aortic dissection. His surgical history was significant for orthotropic heart transplant 19 years prior. The dissection, aneurysm, and rupture occurred in the native aorta distal to the ascending aortic suture line. At presentation, he was hemodynamically unstable with a right hemothorax. We placed 3 Medtronic Talent Thoracic Stent Graft devices (Medtronic Inc, Minneapolis, MN) across the suture line in the ascending aorta, excluding the rupture. The patient survived and has been followed to 25 months.

  7. Association of left subclavian artery coverage without revascularization and spinal cord ischemia in patients undergoing thoracic endovascular aortic repair: A Vascular Quality Initiative® analysis.

    Science.gov (United States)

    Teixeira, Pedro Gr; Woo, Karen; Beck, Adam W; Scali, Salvatore T; Weaver, Fred A

    2017-12-01

    Objectives Investigate the impact of left subclavian artery coverage without revascularization on spinal cord ischemia development in patients undergoing thoracic endovascular aortic repair. Methods The Vascular Quality Initiative thoracic endovascular aortic repair module (April 2011-July 2014) was analyzed. Patients undergoing left subclavian artery coverage were divided into two groups according to revascularization status. The association between left subclavian artery revascularization with the primary outcome of spinal cord ischemia and the secondary outcome of stroke was assessed with multivariable analysis adjusting for between-group baseline differences. Results The left subclavian artery was covered in 508 (24.6%) of the 2063 thoracic endovascular aortic repairs performed. Among patients with left subclavian artery coverage, 58.9% underwent revascularization. Spinal cord ischemia incidence was 12.1% in the group without revascularization compared to 8.5% in the group undergoing left subclavian artery revascularization (odds ratio (95%CI): 1.48(0.82-2.68), P = 0.189). Multivariable analysis adjustment identified an independent association between left subclavian artery coverage without revascularization and the incidence of spinal cord ischemia (adjusted odds ratio (95%CI): 2.29(1.03-5.14), P = 0.043). Although the incidence of stroke was also higher for the group with a covered and nonrevascularized left subclavian artery (12.1% versus 8.5%), this difference was not statistically significant after multivariable analysis (adjusted odds ratio (95%CI): 1.55(0.74-3.26), P = 0.244). Conclusion For patients undergoing left subclavian artery coverage during thoracic endovascular aortic repair, the addition of a revascularization procedure was associated with a significantly lower incidence of spinal cord ischemia.

  8. Identification of type IV collagen exposure as a molecular imaging target for early detection of thoracic aortic dissection

    Science.gov (United States)

    Xu, Ke; Xu, Chen; Zhang, Yanzhenzi; Qi, Feiran; Yu, Bingran; Li, Ping; Jia, Lixin; Li, Yulin; Xu, Fu-jian; Du, Jie

    2018-01-01

    Thoracic aortic dissection (TAD) is an aggressive and life-threatening vascular disease and there is no effective means of early diagnosis of dissection. Type IV collagen (Col-IV) is a major component of the sub-endothelial basement membrane, which is initially exposed followed by endothelial injury as early-stage event of TAD. So, we want to build a noninvasive diagnostic method to detect early dissection by identifying the exposed Col-IV via MRI. Methods: Col-IV-targeted magnetic resonance/ fluorescence dual probe (Col-IV-DOTA-Gd-rhodamine B; CDR) was synthesized by amide reaction and coordination reaction. Flow cytometry analysis was used to evaluate the cell viability of SMC treated with CDR and fluorescence assays were used to assess the Col-IV targeting ability of CDR in vitro. We then examined the sensitivity and specificity of CDR at different stages of TAD via MRI and bioluminescence imaging in vivo. Results: The localization of Col-IV (under the intima) was observed by histology images. CDR bound specifically to Col-IV-expressing vascular smooth muscle cells and BAPN-induced dissected aorta. The CDR signal was co-detected by magnetic resonance imaging (MRI) and bioluminescence imaging as early as 2 weeks after BAPN administration (pre-dissection stage). The ability to detect rupture of dissected aorta was indicated by a strong normalized signal enhancement (NSE) in vivo. Moreover, NSE was negatively correlated with the time of dissection rupture after BAPN administration (r2 = 0.8482). Conclusion: As confirmed by in vivo studies, the CDR can identify the exposed Col-IV in degenerated aorta to monitor the progress of aortic dissection from the early stage to the rupture via MRI. Thus, CDR-enhanced MRI proposes a potential method for dissection screening, and for monitoring disease progression and therapeutic response. PMID:29290819

  9. Retrograde Ascending Dissection After Thoracic Endovascular Aortic Repair Combined With the Chimney Technique and Successful Open Repair Using the Frozen Elephant Trunk Technique.

    Science.gov (United States)

    Hirano, Koji; Tokui, Toshiya; Nakamura, Bun; Inoue, Ryosai; Inagaki, Masahiro; Maze, Yasumi; Kato, Noriyuki

    2018-01-01

    The chimney technique can be combined with thoracic endovascular aortic repair (TEVAR) to both obtain an appropriate landing zone and maintain blood flow of the arch vessels. However, surgical repair becomes more complicated if retrograde type A aortic dissection occurs after TEVAR with the chimney technique. We herein report a case involving a 73-year-old woman who developed a retrograde ascending dissection 3 months after TEVAR for acute type B aortic dissection. To ensure an adequate proximal sealing distance, the proximal edge of the stent graft was located at the zone 2 level and an additional bare stent was placed at the left subclavian artery (the chimney technique) at the time of TEVAR. Enhanced computed tomography revealed an aortic dissection involving the ascending aorta and aortic arch. Surgical aortic repair using the frozen elephant trunk technique was urgently performed. The patient survived without stroke, paraplegia, renal failure, or other major complications. Retrograde ascending dissection can occur after TEVAR combined with the chimney technique. The frozen elephant trunk technique is useful for surgical repair in such complicated cases.

  10. Sequential Hybrid Repair of Aorta and Bilateral Common Iliac Arteries Secondary to Chronic Aortic Dissection with Extensive Aneurysmal Degeneration in a Marfan Patient.

    Science.gov (United States)

    Hinojosa, Carlos A; Anaya-Ayala, Javier E; Laparra-Escareno, Hugo; Lizola, Rene; Torres-Machorro, Adriana

    2017-09-01

    Marfan syndrome is a connective tissue disorder associated with aortic dissection, aneurysmal degeneration and rupture. These cardiovascular complications represent the main cause of mortality, therefore repair is indicated. We present a 35-year-old woman who experienced acute onset of chest pain. Her imaging revealed a chronic DeBakey type I dissection with aortic root dilation and descending thoracic aneurysmal degeneration. She underwent a Bentall procedure and endovascular exclusion of the descending thoracic aortic aneurysm. She was closely followed and 2 years later a computed tomography angiography (CTA) revealed the aneurysmal degeneration of the thoracoabominal aorta and bilateral iliac arteries. The patient underwent a composite reconstruction using multi-visceral branched and bifurcated Dacron grafts. At 5 years from her last surgery, a CTA revealed no new dissection or further aneurysmal degenerations. Aortic disease in Marfan patients is a complex clinical problem that may lead to secondary or tertiary aortic reconstructions; close follow-up is mandatory.

  11. Abnormal secretion or extracellular matrix incorporation of fibrillin by dermal fibroblasts from patients with thoracic aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Milewicz, D.; Cao, S.; Cosselli, J. [Univ. of Texas Medical School, Houston, TX (United States)

    1994-09-01

    Abnormal synthesis, secretion, and extracellular matrix incorporation of fibrillin is observed in the majority of fibroblast cell strains obtained from individuals with the Marfan syndrome (>85%). These fibrillin protein abnormalities are due to mutations in the FBN1 gene. We have screened fibroblast cell strains from patients with thoracic aortic aneurysms (TAA) without skeletal or ocular features of the Marfan syndrome for defects in fibrillin synthesis or processing. Dermal fibroblasts obtained from biopsies were pulse labeled with [{sup 35}S]cysteine for 30 minutes and then chased for 0, 4, and 20 hours. The media, cell lysate and extracellular matrix were harvested separately, then analyzed by SDS-PAGE. We selected fibroblasts from 17 TAA patients to study based on the development of a TAA at a young age or a family history of TAAs. Cells from 3 patients synthesized and secreted fibrillin normally, but did not incorporate the fibrillin in the extracellular matrix. None of the cell strains were found to have diminished synthesis of fibrillin when compared with control cells. We were unable to detect abnormalities in the synthesis, secretion, or matrix incorporation of fibrillin by cells from 9 of the 17 patients. These results indicate that fibrillin protein defects are found in a significant number of patients with TAAs who are young or have a family history of TAAs. Analysis of the FBN1 gene for mutations in these patients with fibrillin protein defects will determine if the observed protein abnormalities are the result of FBN1 gene mutations.

  12. Total Endovascular Aortic Repair in a Patient with Marfan Syndrome.

    Science.gov (United States)

    Amako, Mau; Spear, Rafaëlle; Clough, Rachel E; Hertault, Adrien; Azzaoui, Richard; Martin-Gonzalez, Teresa; Sobocinski, Jonathan; Haulon, Stéphan

    2017-02-01

    The aim of this study is to describe a total endovascular aortic repair with branched and fenestrated endografts in a young patient with Marfan syndrome and a chronic aortic dissection. Open surgery is the gold standard to treat aortic dissections in patients with aortic disease and Marfan syndrome. In 2000, a 38-year-old man with Marfan syndrome underwent open ascending aorta repair for an acute type A aortic dissection. One year later, a redo sternotomy was performed for aortic valve replacement. In 2013, the patient presented with endocarditis and pulmonary infection, which necessitated tracheostomy and temporary dialysis. In 2014, the first stage of the endovascular repair was performed using an inner branched endograft to exclude a 77-mm distal arch and descending thoracic aortic aneurysm. In 2015, a 63-mm thoracoabdominal aortic aneurysm was excluded by implantation of a 4-fenestrated endograft. Follow-up after both endovascular repairs was uneventful. Total aortic endovascular repair was successfully performed to treat a patient with arch and thoraco-abdominal aortic aneurysm associated with chronic aortic dissection and Marfan syndrome. The postoperative images confirmed patency of the endograft and its branches, and complete exclusion of the aortic false lumen. Endovascular repair is a treatment option in patients with connective tissue disease who are not candidates for open surgery. Long-term follow-up is required to confirm these favorable early outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Hybrid treatment of aortic arch disease

    Science.gov (United States)

    Metzger, Patrick Bastos; Rossi, Fabio Henrique; Moreira, Samuel Martins; Issa, Mario; Izukawa, Nilo Mitsuru; Dinkhuysen, Jarbas J.; Spina Neto, Domingos; Kambara, Antônio Massamitsu

    2014-01-01

    Introduction The management of thoracic aortic disease involving the ascending aorta, aortic arch and descending thoracic aorta are technically challenging and is an area in constant development and innovation. Objective To analyze early and midterm results of hybrid treatment of arch aortic disease. Methods Retrospective study of procedures performed from January 2010 to December 2012. The end points were the technical success, therapeutic success, morbidity and mortality, neurologic outcomes, the rate of endoleaks and reinterventions. Results A total of 95 patients treated for thoracic aortic diseases in this period, 18 underwent hybrid treatment and entered in this study. The average ages were 62.3 years. The male was present in 66.7%. The technical and therapeutic success was 94.5% e 83.3%. The perioperative mortality rate of 11.1%. There is any death during one-year follow- up. The reoperation rates were 16.6% due 2 cases of endoleak Ia and one case of endoleak II. There is any occlusion of anatomic or extra anatomic bypass during follow up. Conclusion In our study, the hybrid treatment of aortic arch disease proved to be a feasible alternative of conventional surgery. The therapeutic success rates and re- interventions obtained demonstrate the necessity of thorough clinical follow-up of these patients in a long time. PMID:25714205

  14. Aneurysm-Specific miR-221 and miR-146a Participates in Human Thoracic and Abdominal Aortic Aneurysms

    Directory of Open Access Journals (Sweden)

    Premakumari Venkatesh

    2017-04-01

    Full Text Available Altered microRNA expression is implicated in cardiovascular diseases. Our objective was to determine microRNA signatures in thoracic aortic aneurysms (TAAs and abdominal aortic aneurysms (AAAs compared with control non-aneurysmal aortic specimens. We evaluated the expression of fifteen selected microRNA in human TAA and AAA operative specimens compared to controls. We observed significant upregulation of miR-221 and downregulation of miR-1 and -133 in TAA specimens. In contrast, upregulation of miR-146a and downregulation of miR-145 and -331-3p were found only for AAA specimens. Upregulation of miR-126 and -486-5p and downregulation of miR-30c-2*, -155, and -204 were observed in specimens of TAAs and AAAs. The data reveal microRNA expression signatures unique to aneurysm location and common to both thoracic and abdominal pathologies. Thus, changes in miR-1, -29a, -133a, and -221 are involved in TAAs and miR-145, -146, and -331-3p impact AAAs. This work validates prior studies on microRNA expression in aneurysmal diseases.

  15. Is chest x-ray an adequate screening tool for the diagnosis of blunt thoracic aortic injury?

    Science.gov (United States)

    Ekeh, Akpofure Peter; Peterson, Wylan; Woods, Randy J; Walusimbi, Mbaga; Nwuneli, Nancy; Saxe, Jonathan M; McCarthy, Mary C

    2008-11-01

    Blunt thoracic aortic injuries (BTAI) have a high mortality rate. For survivors, chest X-ray (CXR) findings are used to determine the need for further diagnostic testing with chest computerized tomography with angiography (CTA) or conventional angiography. We set to determine the adequacy of utilizing CXR alone as a screening tool for BTAI. All patients diagnosed with BTAI at a level I trauma-center during a 7-year-period were identified. CXRs of these patients and those of a control group of blunt trauma patients with an injury severity score >15 were reviewed by four trauma surgeons blinded to the diagnosis. Based on each CXR viewed, the surgeons decided if they would have proceeded to chest CTA, angiography, or required no further studies to rule out BTAI. In the 7-year-period, 83 patients had BTAI. CXRs were available in 45 patients. The four surgeons viewed 96 CXRs including those of 51 controls. Based on the CXR appearance in patients with BTAI, the surgeons chose to proceed to chest CTA in 38 patients (84.4%), conventional aortography in two patients (4.4%), and no further testing in five patients (11.2%). A widened mediastinum (75%) and loss of the aorto-pulmonary window (40%) were the most frequent CXR abnormalities. Patients with BTAI were more likely to have an abnormal CXR-40 of 45 (88.8%) patients when compared with the controls-25 of 51 (49%)patients-p < 0.001. Although CXR is a sensitive screening modality, it failed to identify the possibility of BTAI in 11% of patients. The liberal use of chest CTA after high speed motor vehicle crashes is recommended to minimize the incidence of missed BTAI.

  16. Physiologic Functional Evaluation of Left Internal Mammary Artery Graft to Left Anterior Descending Coronary Artery Steal due to Unligated First Thoracic Branch in a Case of Refractory Angina

    Directory of Open Access Journals (Sweden)

    Fadi J. Sawaya

    2016-01-01

    Full Text Available Unligated side branches of the left internal mammary artery (LIMA have been described in the literature as a cause of coronary steal resulting in angina. Despite a number of studies reporting successful side branch embolization to relieve symptoms, this phenomenon remains controversial. Hemodynamic evidence of coronary steal using angiographic and intravascular Doppler techniques has been supported by some and rejected by others. In this case study using an intracoronary Doppler wire with adenosine, we demonstrate that a trial occlusion of the LIMA thoracic side branch with selective balloon inflation can confirm physiologic significant steal and whether coil embolization of the side branch is indicated.

  17. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  18. Aortic Blood Flow Reversal Determines Renal Function: Potential Explanation for Renal Dysfunction Caused by Aortic Stiffening in Hypertension.

    Science.gov (United States)

    Hashimoto, Junichiro; Ito, Sadayoshi

    2015-07-01

    Aortic stiffness determines the glomerular filtration rate (GFR) and predicts the progressive decline of the GFR. However, the underlying pathophysiological mechanism remains obscure. Recent evidence has shown a close link between aortic stiffness and the bidirectional (systolic forward and early diastolic reverse) flow characteristics. We hypothesized that the aortic stiffening-induced renal dysfunction is attributable to altered central flow dynamics. In 222 patients with hypertension, Doppler velocity waveforms were recorded at the proximal descending aorta to calculate the reverse/forward flow ratio. Tonometric waveforms were recorded to measure the carotid-femoral (aortic) and carotid-radial (peripheral) pulse wave velocities, to estimate the aortic pressure from the radial waveforms, and to compute the aortic characteristic impedance. In addition, renal hemodynamics was evaluated by duplex ultrasound. The estimated GFR was inversely correlated with the aortic pulse wave velocity, reverse/forward flow ratio, pulse pressure, and characteristic impedance, whereas it was not correlated with the peripheral pulse wave velocity or mean arterial pressure. The association between aortic pulse wave velocity and estimated GFR was independent of age, diabetes mellitus, hypercholesterolemia, and antihypertensive medication. However, further adjustment for the aortic reverse/forward flow ratio and pulse pressure substantially weakened this association, and instead, the reverse/forward flow ratio emerged as the strongest determinant of estimated GFR (P=0.001). A higher aortic reverse/forward flow ratio was also associated with lower intrarenal forward flow velocities. These results suggest that an increase in aortic flow reversal (ie, retrograde flow from the descending thoracic aorta toward the aortic arch), caused by aortic stiffening and impedance mismatch, reduces antegrade flow into the kidney and thereby deteriorates renal function. © 2015 American Heart Association

  19. Acute aortic syndromes: definition, prognosis and treatment options.

    Science.gov (United States)

    Carpenter, S W; Kodolitsch, Y V; Debus, E S; Wipper, S; Tsilimparis, N; Larena-Avellaneda, A; Diener, H; Kölbel, T

    2014-04-01

    Acute aortic syndromes (AAS) are life-threatening vascular conditions of the thoracic aorta presenting with acute pain as the leading symptom in most cases. The incidence is approximately 3-5/100,000 in western countries with increase during the past decades. Clinical suspicion for AAS requires immediate confirmation with advanced imaging modalities. Initial management of AAS addresses avoidance of progression by immediate medical therapy to reduce aortic shear stress. Proximal symptomatic lesions with involvement of the ascending aorta are surgically treated in the acute setting, whereas acute uncomplicated distal dissection should be treated by medical therapy in the acute period, followed by surveillance and repeated imaging studies. Acute complicated distal dissection requires urgent invasive treatment and thoracic endovascular aortic repair has become the treatment modality of choice because of favorable outcomes compared to open surgical repair. Intramural hematoma, penetrating aortic ulcers, and traumatic aortic injuries of the descending aorta harbor specific challenges compared to aortic dissection and treatment strategies are not as uniformly defined as in aortic dissection. Moreover these lesions have a different prognosis. Once the acute period of aortic syndrome has been survived, a lifelong medical treatment and close surveillance with repeated imaging studies is essential to detect impending complications which might need invasive treatment within the short-, mid- or long-term.

  20. Extended replacement of the thoracic aorta.

    Science.gov (United States)

    Hino, Yutaka; Okada, Kenji; Oka, Takanori; Inoue, Takeshi; Tanaka, Akiko; Omura, Atsushi; Kano, Hiroya; Okita, Yutaka

    2013-01-01

    We present our experience of total aortic arch replacement. Twenty-nine patients (21 males and 8 females; mean age 63.3 ± 13.3 years) with extended thoracic aortic aneurysms underwent graft replacement. The pathology of the diseased aorta was non-dissecting aneurysm in 11 patients, including one aortitis and aortic dissection in 18 patients (acute type A: one, chronic type A: 11, chronic type B: six). Five patients had Marfan syndrome. In their previous operation, two patients had undergone the Bentall procedure, three had endovascular stenting, one had aortic root replacement with valve sparing and 12 had hemi-arch replacement for acute type A dissection. Approaches to the aneurysm were as follows: posterolateral thoracotomy with rib-cross incision in 16, posterolateral thoracotomy extended to the retroperitoneal abdominal aorta in seven, mid-sternotomy and left pleurotomy in three, anterolateral thoracotomy with partial lower sternotomy in two and clam-shell incision in one patient. Extension of aortic replacement was performed from the aortic root to the descending aorta in 4, from the ascending aorta to the descending aorta in 17 and from the ascending to the abdominal aorta in eight patients. Arterial inflow for cardiopulmonary bypass consisted of the femoral artery in 15 patients, ascending aorta and femoral artery in seven, descending or abdominal aorta in five and ascending aorta in two. Venous drainage site was the femoral vein in 10, pulmonary artery in eight, right atrium in five, femoral artery with right atrium/pulmonary artery in four and pulmonary artery with right atrium in two patients. The operative mortality, 30-day mortality and hospital mortality was one (cardiac arrest due to aneurysm rupture), one (rupture of infected aneurysm) and one (brain contusion), respectively. Late mortality occurred in three patients due to pneumonia, ruptured residual aneurysm and intracranial bleeding. Actuarial survival at 5 years after the operations was 80.6

  1. Endovascular treatment of aortic pathologies - State of the art. Part 2 - Pathologies of thoracic aorta and other applications

    International Nuclear Information System (INIS)

    Uribe, Carlos E; Calderon, Luis L; Gomez, German S; Castro, Pablo; Hurtado, Edgar F; Estrada, Gilberto

    2007-01-01

    Endovascular treatment of aortic pathologies is actually an alternative to open surgery. It has proven to be safe, showing similar or better results to those achieved by surgery. In this article, treatment of aortic pathologies by means of endoprosthesis is presented, as well as its indications, contraindications and future treatment with this kind of devices

  2. Thoracic Malignancies and Pulmonary Nodules in Patients under Evaluation for Transcatheter Aortic Valve Implantation (TAVI): Incidence, Follow Up and Possible Impact on Treatment Decision

    Science.gov (United States)

    Kaleschke, Gerrit; Schülke, Christoph; Görlich, Dennis; Schliemann, Christoph; Kessler, Torsten; Schulze, Arik Bernard; Buerke, Boris; Kuemmel, Andreas; Thrull, Michael; Wiewrodt, Rainer; Baumgartner, Helmut; Berdel, Wolfgang E.; Mohr, Michael

    2016-01-01

    Background Transcatheter aortic valve implantation (TAVI) has become the treatment of choice in patients with severe aortic valve stenosis who are not eligible for operative replacement and an alternative for those with high surgical risk. Due to high age and smoking history in a high proportion of TAVI patients, suspicious findings are frequently observed in pre-procedural chest computer tomography (CCT). Methods CCT scans of 484 consecutive patients undergoing TAVI were evaluated for incidentally discovered solitary pulmonary nodules (SPN). Results In the entire study population, SPN ≥ 5 mm were found in 87 patients (18%). These patients were compared to 150 patients who were incidentally collected from the 397 patients without SPN or with SPN 8 mm (p = 0.328) were significant predictors of overall survival. Conclusions Despite the high prevalence of SPNs in this single center TAVI cohort lung cancer incidence at midterm follow-up seems to be low. Thus, aggressive diagnostic approaches for incidentally discovered SPN during TAVI evaluation should not delay the treatment of aortic stenosis. Unless advanced thoracic malignancy is obvious, the well documented reduction of morbidity and mortality by TAVI outweighs potentially harmful delays regarding further diagnostics. Standard guideline-approved procedure for SPN can be safely performed after TAVI. PMID:27171441

  3. Thoracic aortic aneurysm

    Science.gov (United States)

    ... age Connective tissue disorders such as Marfan or Ehlers-Danlos syndrome Inflammation of the aorta Injury from falls or ... of connective tissue disorders (such as Marfan or Ehlers-Danlos syndrome) Chest or back discomfort Prevention To prevent atherosclerosis: ...

  4. Ascending aortic injuries following blunt trauma.

    Science.gov (United States)

    Sun, Xiumei; Hong, Jenny; Lowery, Robert; Goldstein, Steven; Wang, Zuyue; Lindsay, Joseph; Hill, Peter C; Corso, Paul J

    2013-11-01

    The diagnosis and the management of traumatic thoracic aortic injuries have undergone significant changes due to new technology and improved prehospital care. Most of the discussions have focused on descending aortic injuries. In this review, we discuss the recent management of ascending aortic injuries. We found 5 cohort studies on traumatic aortic injuries and 11 case reports describing ascending aortic injuries between 1998 to the present through Medline research. Among case reports, 78.9% of cases were caused by motor vehicle accidents (MVA). 42.1% of patients underwent emergent open repair and the operative mortality was 12.5%. 36.8% underwent delayed repair. Associated injuries occurred in 84.2% of patients. Aortic valve injury was concurrent in 26.3% of patients. The incidence of ascending aortic injury ranged 1.9-20% in cohort studies. Traumatic injuries to the ascending aorta are relatively uncommon among survivors following blunt trauma. Aortography has been replaced by computed tomography and echocardiography as a diagnostic tool. Open repair, either emergent or delayed, remains the treatment of choice. © 2013 Wiley Periodicals, Inc.

  5. Altered aortic shape in bicuspid aortic valve relatives influences blood flow patterns.

    Science.gov (United States)

    Schnell, Susanne; Smith, Danielle A; Barker, Alex J; Entezari, Pegah; Honarmand, Amir R; Carr, Maria L; Malaisrie, S Chris; McCarthy, Patrick M; Collins, Jeremy; Carr, James C; Markl, Michael

    2016-11-01

    Bicuspid aortic valve (BAV) is known to exhibit familial inheritance and is associated with aortopathy and altered aortic haemodynamics. However, it remains unclear whether BAV-related aortopathy can be inherited independently of valve morphology. Four-dimensional flow magnetic resonance imaging for the in vivo assessment of thoracic aortic 3D blood flow was performed in 24 BAV relatives with trileaflet aortic valves (age = 40 ± 14 years) and 15 healthy controls (age = 37 ± 10 years). Data analysis included aortic dimensions, shape (round/gothic/cubic), and 3D blood flow characteristics (semi-quantitative vortex/helix grading and peak velocities). Cubic and gothic aortic shapes were markedly more prevalent in BAV relatives compared with controls (38 vs. 7%). Ascending aorta (AAo) vortex flow in BAV relatives was significantly increased compared with controls (grading = 1.5 ± 1.0 vs. 0.6 ± 0.9, P = 0.015). Aortic haemodynamics were influenced by aortic shape: peak velocities were reduced for gothic aortas vs. round aortas (P = 0.003); vortex flow was increased for cubic aortas in the AAo (P gothic aortas in the AAo and descending aorta (P = 0.003, P = 0.029). Logistic regression demonstrated significant associations of shape with severity of vortex flow in AAo (P < 0.001) and aortic arch (P = 0.016) in BAV relatives. BAV relatives expressed altered aortic shape and increased vortex flow despite the absence of valvular disease or aortic dilatation. These data suggest a heritable component of BAV-related aortopathy affecting aortic shape and aberrant blood flow, independent of valve morphology. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  6. Transcatheter valve implantation for patients with aortic stenosis: A position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

    NARCIS (Netherlands)

    A. Vahanian (Alec); O. Alfieri (Ottavio); N. Al-Attar (Nawwar); M. Antunes (Manuel); J.J. Bax (Jeroen); B. Cormier (Bertrand); A. Cribier (Alain); P.P.T. de Jaegere (Peter); G. Fournial (Gerard); A.P. Kappetein (Arie Pieter); J. Kovac (Jan); S. Ludgate (Susanne); F. Maisano (Francesco); N. Moat (Neil); F.W. Mohr (Friedrich); P. Nataf (Patrick); L. Pierard (Luc); J.L. Pomar (Jose); J. Schofer (Joachim); P. Tornos (Pilar); M. Tuzcu (Murat); B.A. van Hout (Ben); L.K. von Segesser (Ludwig); T. Walther (Thomas)

    2008-01-01

    textabstractAims: To critically review the available transcatheter aortic valve implantation techniques and their results, as well as propose recommendations for their use and development. Methods and results: A committee of experts including European Association of Cardio-Thoracic Surgery and

  7. Pré-condicionamento isquêmico e monitorização da função medular na abordagem da aorta torácica descendente Ischemic preconditioning and spinal cord function monitoring in the descending thoracic aorta approach

    Directory of Open Access Journals (Sweden)

    Bernardo Assumpção de Mônaco

    2007-03-01

    Full Text Available OBJETIVOS: Avaliar a eficácia do pré-condicionamento isquêmico (PI agudo, guiado por potenciais evocados somatossensoriais (PESS, como método de proteção medular em cães e analisar o valor dos PESS na monitorização da função medular. MÉTODOS: Foram utilizados 28 cães submetidos à isquemia medular obtida pelo pinçamento da aorta torácica descendente. No grupo C45, o tempo de oclusão aórtica foi de 45 min (n = 7; no grupo PI45, os cães foram submetidos ao PI antes do pinçamento aórtico por 45 min (n = 7. No grupo C60, os cães foram submetidos a 60 min de oclusão aórtica (n = 7 e no grupo PI60, os cães foram submetidos ao PI, seguido pelo pinçamento aórtico por 60 min. Os ciclos de PI foram determinados pelas alterações dos PESS. RESULTADOS: Os índices de Tarlov dos grupos pré-condicionados foram significativamente melhores que os dos grupos de controle (p = 0,005. Observou-se paraplegia em três cães do C45 e em seis do C60, enquanto todos os cães do PI45 permaneceram neurologicamente normais, assim como quatro do grupo PI60. Houve correlação entre o tempo de recuperação dos PESS após a reperfusão aórtica e o estado neurológico pós-operatório (p = 0,011, com sensibilidade e especificidade de 0,75 e 0,83, respectivamente. CONCLUSÃO: O PI agudo repetitivo, baseado na monitorização do PESS, induziu proteção à isquemia medular causada pelo pinçamento aórtico prolongado. A monitorização do PESS parece ser um bom método de detecção precoce do comprometimento isquêmico medular.OBJECTIVES: To evaluate the effectiveness of acute ischemic preconditioning (IP, based on somatosensory evoked potentials (SSEP monitoring, as a method of spinal cord protection and to asses SSEP importance in spinal cord neuromonitoring. METHODS: Twenty-eight dogs were submitted to spinal cord ischemic injury attained by descending thoracic aorta cross-clamping. In the C45 group, the aortic cross-clamping time was 45 min (n

  8. Effect of cannula shape on aortic wall and flow turbulence: hydrodynamic study during extracorporeal circulation in mock thoracic aorta.

    Science.gov (United States)

    Minakawa, Masahito; Fukuda, Ikuo; Yamazaki, Junichi; Fukui, Kozo; Yanaoka, Hideki; Inamura, Takao

    2007-12-01

    This study was designed to analyze flow pattern, velocity, and strain on the aortic wall of a glass aortic model during extracorporeal circulation, and to elucidate the characteristics of flow pattern in four aortic cannulas. Different patterns of large vortices and helical flow were made by each cannula. The high-velocity flow (0.6 m/s) was observed in end-hole cannula, causing high strain rate tensor (0.3~0.4 without unit) on the aortic arch. In dispersion cannula, a decreased strain rate tensor (less than 0.1) was found on the outer curvature of the aortic arch. In Soft-flow cannula (3M Cardiovascular, Ann Arbor, MI, USA), further decreased flow velocity (0.2 m/s) and strain (less than 0.2) were observed. In Select 3D cannula (Medtronic, Inc., Minneapolis, MN, USA), a high strain (0.4~0.5) was observed along the inner curvature of the aortic arch. In conclusion, end-hole cannula should not be used in atherosclerotic aorta. Particular attention should be paid both for selection of cannulas and cannulation site based on this result.

  9. New Technique for the Preservation of the Left Common Carotid Artery in Zone 2a Endovascular Repair of Thoracic Aortic Aneurysm

    International Nuclear Information System (INIS)

    Juszkat, Robert; Kulesza, Jerzy; Zarzecka, Anna; Jemielity, Marek; Staniszewski, Ryszard; Majewski, Wacław

    2011-01-01

    To describe a technique for the preservation of the left common carotid artery (CCA) in zone 2 endovascular repair of thoracic aortic aneurysm. This technique involves the placement of a guide wire into the left CCA via the right brachial artery before stent graft deployment to enable precise visualization and protection of the left CCA during the whole procedure. Of the 107 patients with thoracic endovascular aortic repair in our study, 32 (30%) had the left subclavian artery intentionally covered (landing zone 2). Eight (25%) of those 32 had landing zone 2a—the segment distally the origin of the left CCA, halfway between the origin of the left CCA and the left subclavian artery. In all patients, a guide wire was positioned into the left CCA via the right brachial artery before stent graft deployment. It is a retrospective study in design. In seven patients, stent grafts were positioned precisely. In the remaining patient, the positioning was imprecise; the origin of the left CCA was partially covered by the graft. A stent was implanted into the left CCA to restore the flow into the vessel. All procedures were performed successfully. The technique of placing a guide wire into the left CCA via the right brachial artery before stent graft deployment is a safe and effective method that enables the precise visualization of the left CCA during the whole procedure. Moreover, in case of inadvertent complete or partial coverage of the origin of the left CCA, it supplies safe and quick access to the artery for stent implantation.

  10. Video-assisted thoracoscopic left lower lobectomy in a patient with lung cancer and a right aortic arch

    Directory of Open Access Journals (Sweden)

    Wada Hideyuki

    2012-11-01

    Full Text Available Abstract A right aortic arch is a rare congenital anomaly, with a reported incidence of around 0.1%. A patient with a right aortic arch underwent video-assisted thoracic surgery left lower lobectomy and mediastinal lymph node dissection for squamous cell carcinoma. There was no aortic arch or descending aorta in the left thoracic cavity, but the esophagus. There was no anomaly in the location or branching of the pulmonary vessels, the bronchi, and the lobulation of the lungs. The vagus nerve was found at the level of the left pulmonary artery. The arterial ligament was found between the left subclavian artery and the left pulmonary artery. The recurrent laryngeal nerve was recurrent around the left subclavian artery. A Kommerell diverticulum was found at the origin of the left subclavian artery. The patient experienced no complications. We conclude that video-assisted thoracoscopic lobectomy with mediastinal dissection is feasible for treating lung cancer with a right aortic arch.

  11. Normal values of aortic dimensions, distensibility, and pulse wave velocity in children and young adults: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Voges Inga

    2012-11-01

    Full Text Available Abstract Background Aortic enlargement and impaired bioelasticity are of interest in several cardiac and non-cardiac diseases as they can lead to cardiovascular complications. Cardiovascular magnetic resonance (CMR is increasingly accepted as a noninvasive tool in cardiovascular evaluation. Assessment of aortic anatomy and bioelasticity, namely aortic distensibility and pulse wave velocity (PWV, by CMR is accurate and reproducible and could help to identify anatomical and bioelastic abnormalities of the aorta. However, normal CMR values for healthy children and young adults are lacking. Methods Seventy-one heart-healthy subjects (age 16.4 ± 7.6 years, range 2.3 - 28.3 years were examined using a 3.0 Tesla CMR scanner. Aortic cross-sectional areas and aortic distensibility were measured at four positions of the ascending and descending thoracic aorta. PWV was assessed from aortic blood flow velocity measurements in a aortic segment between the ascending aorta and the proximal descending aorta. The Lambda-Mu-Sigma (LMS method was used to obtain percentile curves for aortic cross-sectional areas, aortic distensibility and PWV according to age. Results Aortic areas, PWV and aortic distensibility (aortic cross-sectional areas: r = 0.8 to 0.9, p  Conclusions This study provides percentile curves for cross-sectional areas, distensibility and pulse wave velocity of the thoracic aorta in children and young adolescents between their 3rd and 29th year of life. These data may serve as a reference for the detection of pathological changes of the aorta in cardiovascular disease.

  12. What is the optimal myocardial preservation strategy at re-operation for aortic valve replacement in the presence of a patent internal thoracic artery?

    Science.gov (United States)

    Park, Chan B; Suri, Rakesh M; Burkhart, Harold M; Greason, Kevin L; Dearani, Joseph A; Schaff, Hartzell V; Sundt, Thoralf M

    2011-06-01

    The optimal myocardial preservation strategy at re-operation for aortic valve replacement (AVR) after prior coronary artery bypass grafting (CABG) in the presence of a patent internal thoracic artery (ITA) remains undefined. Patients undergoing AVR after prior CABG at our institution between 1 January 1996 and 31 December 2007 were identified; operative notes and outcomes were reviewed. Of 628 patients with prior CABG undergoing AVR with or without concomitant procedures, 427 patients had a patent ITA. In 390, management of the ITA was detailed in the operative note, including 251 in whom it was clamped and 139 in whom it was left uncontrolled. Groups were demographically similar, although re-operative CABG was more frequent in the clamped group (42% vs 23%, poptimal perfusion temperature when the ITA was left uncontrolled. Efforts to control the patent ITA at re-operation for AVR after prior CABG increase risk of injury and may actually increase operative mortality rate compared with leaving this critical graft open and perfusing the heart. Copyright © 2010 European Association for Cardio-Thoracic Surgery. All rights reserved.

  13. Aortic Dissection Type A in Alpine Skiers

    Directory of Open Access Journals (Sweden)

    Thomas Schachner

    2013-01-01

    Full Text Available Patients and Methods. 140 patients with aortic dissection type A were admitted for cardiac surgery. Seventy-seven patients experienced their dissection in the winter season (from November to April. We analyzed cases of ascending aortic dissection associated with alpine skiing. Results. In 17 patients we found skiing-related aortic dissections. Skiers were taller (180 (172–200 cm versus 175 (157–191 cm, and heavier (90 (68–125 kg versus 80 (45–110 kg, than nonskiers. An extension of aortic dissection into the aortic arch, the descending thoracic aorta, and the abdominal aorta was found in 91%, 74%, and 69%, respectively, with no significant difference between skiers and nonskiers. Skiers experienced RCA ostium dissection requiring CABG in 17.6% while this was true for 5% of nonskiers (. Hospital mortality of skiers was 6% versus 13% in nonskiers (. The skiers live at an altitude of 170 (0–853 m.a.s.l. and experience their dissection at 1602 (1185–3105; m.a.s.l. In 82% symptom start was during recreational skiing without any trauma. Conclusion. Skiing associated aortic dissection type A is usually nontraumatic. The persons affected live at low altitudes and practice an outdoor sport at unusual high altitude at cold temperatures. Postoperative outcome is good.

  14. Aortic Dissection Type A in Alpine Skiers

    Science.gov (United States)

    Schachner, Thomas; Fischler, Nikolaus; Dumfarth, Julia; Bonaros, Nikolaos; Krapf, Christoph; Schobersberger, Wolfgang; Grimm, Michael

    2013-01-01

    Patients and Methods. 140 patients with aortic dissection type A were admitted for cardiac surgery. Seventy-seven patients experienced their dissection in the winter season (from November to April). We analyzed cases of ascending aortic dissection associated with alpine skiing. Results. In 17 patients we found skiing-related aortic dissections. Skiers were taller (180 (172–200) cm versus 175 (157–191) cm, P = 0.008) and heavier (90 (68–125) kg versus 80 (45–110) kg, P = 0.002) than nonskiers. An extension of aortic dissection into the aortic arch, the descending thoracic aorta, and the abdominal aorta was found in 91%, 74%, and 69%, respectively, with no significant difference between skiers and nonskiers. Skiers experienced RCA ostium dissection requiring CABG in 17.6% while this was true for 5% of nonskiers (P = 0.086). Hospital mortality of skiers was 6% versus 13% in nonskiers (P = 0.399). The skiers live at an altitude of 170 (0–853) m.a.s.l. and experience their dissection at 1602 (1185–3105; P < 0.001) m.a.s.l. In 82% symptom start was during recreational skiing without any trauma. Conclusion. Skiing associated aortic dissection type A is usually nontraumatic. The persons affected live at low altitudes and practice an outdoor sport at unusual high altitude at cold temperatures. Postoperative outcome is good. PMID:23971024

  15. Transesophageal access to the cardiac cavities and descending thoracic aorta via echoendoscopy: An experimental study Acceso transesofágico a cavidades cardiacas y aorta torácica descendente mediante ecoendoscopia: Estudio experimental

    Directory of Open Access Journals (Sweden)

    A. López Martín

    2009-09-01

    Full Text Available Objective: the applications of endoscopic ultrasonography have diversified over recent years. The possibility of reaching cardiac territory has been successfully explored in experimental models, opening up a new field of possibilities for diagnostic and therapeutic interventions that were unthinkable until very recently. The aims set out in this study are to evaluate cardiac anatomy, its approach, the safety of the experimental procedure and the resulting morphological and histological changes after the procedure. Material and methods: the study has been performed on two adult pigs. They have undergone different surgical approaches to the cardiac cavities and descending thoracic aorta with excellent results. Results: different cardiac structures have been identified and operated upon (right auricle, left auricle, left ventricle, cardiac valves, as well as major vessels. The use of contrast, both intracavitary and from a peripheral vein, enabled us to verify the anatomical spaces studied. During the procedures we monitored for arrhythmias, hemodynamic behavior, possibility of infection by obtaining sample hemocultures before and after procedures, and response to punctures. Conclusions: the present study has enabled us to evaluate access to the heart from the esophageal lumen using endoscopic ultrasonography, with results that are very similar to those described in the current bibliography. However, we offer two novelties: puncture of the right auricle through the interauricular partition and puncture of the descending thoracic aorta, both performed with ease and apparent safety.Objetivo: las aplicaciones de la ultrasonografía endoscópica se han diversificado en los últimos tiempos. La posibilidad de acceder al territorio cardiaco se ha explorado en modelos experimentales con buenos resultados, abriendo un campo de nuevas posibilidades de intervencionismo diagnóstico y terapéutico hasta hace poco impensables. Los objetivos planteados en este

  16. Association of Tricuspid Regurgitation With Transcatheter Aortic Valve Replacement Outcomes: A Report From The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry.

    Science.gov (United States)

    McCarthy, Fenton H; Vemulapalli, Sreekanth; Li, Zhuokai; Thourani, Vinod; Matsouaka, Roland A; Desai, Nimesh D; Kirtane, Ajay; Anwaruddin, Saif; Williams, Matthew L; Giri, Jay; Vallabhajosyula, Prashanth; Li, Robert H; Herrmann, Howard C; Bavaria, Joseph E; Szeto, Wilson Y

    2018-04-01

    The purpose of this study is to evaluate the association of tricuspid regurgitation (TR) severity with outcomes after transcatheter aortic valve replacement (TAVR). We analyzed data from 34,576 patients who underwent TAVR at 365 US hospitals from November 2011 through March 2015 submitted to The Society of Thoracic Surgeon/American College of Cardiology Transcatheter Valve Therapy Registry. We examined unadjusted mortality and heart failure readmission stratified by degree of preoperative TR and used multivariable models for 1-year mortality and heart failure readmission. Tricuspid regurgitation was present in 80% (n = 27,804) of TAVR patients, with mild TR in 56% (n = 19,393), moderate TR in 19% (n = 6687), and severe TR in 5% (n = 1,724). Increasing TR severity was associated with a number of comorbidities and The Society of Thoracic Surgeons predicted risk of mortality increased (p < 0.001): no TR (7.3 ± 5.4); mild TR (8.0 ± 5.7); moderate TR (9.6 ± 6.8); and severe TR (10.7 ± 7.4). In unadjusted analysis, moderate and severe TR were associated with increased use of cardiopulmonary bypass, longer intensive care unit and hospital stays, new dialysis, inhospital major adverse cardiac event, inhospital mortality, observed-to-expected inhospital mortality ratio, long-term heart failure readmission, and mortality (p < 0.001). Adjusted mortality at 1 year was significantly worse for patients with severe TR when left ventricular ejection fraction greater than 30% (hazard ratio 1.29, 95% confidence interval: 1.11 to 1.50) as was heart failure readmission (hazard ratio 1.27, 95% confidence interval: 1.04 to 1.54). Tricuspid regurgitation was common among patients undergoing TAVR. Increasing TR severity was associated with higher risk patients and increased mortality and readmission-particularly for patients with severe TR and left ventricular ejection fraction greater than 30%. The effectiveness of TAVR alone in patients with aortic stenosis and concomitant

  17. Anatomic factors associated with acute endograft collapse after Gore TAG treatment of thoracic aortic dissection or traumatic rupture.

    NARCIS (Netherlands)

    Muhs, B.E.; Balm, R.; White, G.H.; Verhagen, H.J.M.

    2007-01-01

    OBJECTIVE: The potentially devastating complication of total or near total thoracic endoprosthesis collapse has been described with the TAG device (W. L. Gore & Associates, Flagstaff, Ariz). This rare complication has resulted in a warning to clinicians and speculation about the etiology of this

  18. Anatomic factors associated with acute endograft collapse after Gore TAG treatment of thoracic aortic dissection or traumatic rupture

    NARCIS (Netherlands)

    Muhs, Bart E.; Balm, Ron; White, Geoffrey H.; Verhagen, Hence J. M.

    2007-01-01

    OBJECTIVE: The potentially devastating complication of total or near total thoracic endoprosthesis collapse has been described with the TAG device (W. L. Gore & Associates, Flagstaff, Ariz). This rare complication has resulted in a warning to clinicians and speculation about the etiology of this

  19. MR imaging of the thoracic aorta in patients with Marfan syndrome

    International Nuclear Information System (INIS)

    Sommerhoff, B.A.; Sechtem, U.P.; Schiller, N.B.; Higgins, C.B.

    1986-01-01

    Gated MR imaging was used to evaluate the thoracic aorta in 11 with Marfan syndrome, eight patients with aneurysm of the ascending aorta, and 20 healthy subjects. The aortic diameter was measured on transverse and sagittal images at the levels of the sinuses of Valsalva, the caudal portion of the ascending aorta, the prearch region, the middle arch, and the descending aorta. The sinus of Valsalva-prearch region aortic diameter ratio in patients with Marfan syndrome was significantly greater than in the two other groups, indicating the characteristic shape of the Maranoid aorta. MR imaging allows definitive measurements' of aortic dimensions and is a valuable noninvasive method for monitoring the course of aortic enlargement

  20. [Surgical results for aortic involvement in Marfan syndrome].

    Science.gov (United States)

    Shiiya, N; Matsuzaki, K; Maruyama, R; Kunihara, T; Murashita, T; Aoki, H; Yasuda, K

    2002-07-01

    From 1991 through 2001, 21 Marfan patients underwent aortic operations in our hospital. They received a total of 36 aortic operations, 31 by ourselves including 4 non-elective operations and 2 operations before 1991. Extent of replacement was Bentall + total arch (4), Bentall (8), valve sparing aortic root (reimplantation) (2), re-anastomosis + coronary aortic bypass grafting (CABG) after Bentall (1), ascending + total arch (3), ascending (1), total arch (1), total thoracoabdominal (10), thoracoabdominal (1), descending thoracic (2), distal arch (1), abdominal (2). Multiple operations were required in 11 patients (2 operations in 7, 3 operations in 4). Eight reoperations in 6 patients were for adjacent lesion, 5 reoperations were for remote lesion, and 2 others were for complication of Bentall (initial operation elsewhere). Among the 8 reoperations for adjacent lesion, 3 were scheduled operation (2 with elephant trunk), 4 were for residual dissection, and 1 was for annulo-aortic ectasia (AAE). Total aortic replacement was achieved in 4 and subtotal replacement excluding the root in 2. There was no hospital mortality. Paraparesis occurred in 1 who died 4.7 years after operation. The remaining patients are currently alive. No other aortic event occurred. Aortic reoperation-free survival was 83% at 5 year and 28% at 10 year.

  1. [Commentary by the German Society for Thoracic and Cardiovascular Surgery on the positions statement by the German Cardiology Society on quality criteria for transcatheter aortic valve implantation (TAVI)].

    Science.gov (United States)

    Cremer, Jochen; Heinemann, Markus K; Mohr, Friedrich Wilhelm; Diegeler, Anno; Beyersdorf, Friedhelm; Niehaus, Heidi; Ensminger, Stephan; Schlensak, Christian; Reichenspurner, Hermann; Rastan, Ardawan; Trummer, Georg; Walther, Thomas; Lange, Rüdiger; Falk, Volkmar; Beckmann, Andreas; Welz, Armin

    2014-12-01

    Surgical aortic valve replacement is still considered the first-line treatment for patients suffering from severe aortic valve stenosis. In recent years, transcatheter aortic valve implantation (TAVI) has emerged as an alternative for selected high-risk patients. According to the latest results of the German external quality assurance program, mandatory by law, the initially very high mortality and procedural morbidity have now decreased to approximately 6 and 12%, respectively. Especially in Germany, the number of patients treated by TAVI has increased exponentially. In 2013, a total of 10.602 TAVI procedures were performed. TAVI is claimed to be minimally invasive. This is true concerning the access, but it does not describe the genuine complexity of the procedure, defined by the close neighborhood of the aortic valve to delicate intracardiac structures. Hence, significant numbers of life-threatening complications may occur and have been reported. Owing to the complexity of TAVI, there is a unanimous concordance between cardiologists and cardiac surgeons in the Western world demanding a close heart team approach for patient selection, intervention, handling of complications, and pre- as well as postprocedural care, respectively. The prerequisite is that TAVI should not be performed in centers with no cardiac surgery on site. This is emphasized in all international joint guidelines and expert consensus statements. Today, a small number of patients undergo TAVI procedures in German hospitals without a department of cardiac surgery on site. To be noted, most of these hospitals perform less than 20 cases per year. Recently, the German Cardiac Society (DGK) published a position paper supporting this practice pattern. Contrary to this statement and concerned about the safety of patients treated this way, the German Society for Thoracic and Cardiovascular Surgery (DGTHG) still fully endorses the European (ESC/EACTS) and other actual international guidelines and

  2. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography

    International Nuclear Information System (INIS)

    Lucarelli, Claudio Luiz

    1995-01-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  3. Myocardial ischemia due to compression of an unruptured thoracic aortic aneurysm in a patient with Marfan syndrome.

    Science.gov (United States)

    Minami, Hiroya; Asada, Tatsuro; Gan, Kunio; Abe, Koichiro; Izumi, Satoshi

    2007-06-01

    We report a 33-year-old woman who had a 60-mm thoracic aneurysm of the ascending aorta with Marfan syndrome and effort angina due to compression of the right coronary artery (RCA) by the aneurysm. Surgery was performed using the Bentall procedure and a coronary artery bypass graft to the RCA. Postoperatively, coronary angiography showed that the coronary flow of the RCA was restored by removing the aneurysmal compression. The patient was discharged without angina on postoperative day 21.

  4. Endovascular Repair of Aortic Dissection in Marfan Syndrome: Current Status and Future Perspectives

    Directory of Open Access Journals (Sweden)

    Rosario Parisi

    2015-07-01

    Full Text Available Over the last decades, improvement of medical and surgical therapy has increased life expectancy in Marfan patients. Consequently, the number of such patients requiring secondary interventions on the descending thoracic aorta due to new or residual dissections, and distal aneurysm formation has substantially enlarged. Surgical and endovascular procedures represent two valuable options of treatment, both associated with advantages and drawbacks. The aim of the present manuscript was to review endovascular outcomes in Marfan syndrome and to assess the potential role of Thoracic Endovascular Aortic Repair (TEVAR in this subset of patients.

  5. Sodium bicarbonate use and the risk of hypernatremia in thoracic aortic surgical patients with metabolic acidosis following deep hypothermic circulatory arrest

    Directory of Open Access Journals (Sweden)

    Kamrouz Ghadimi

    2016-01-01

    Full Text Available Objective: Metabolic acidosis after deep hypothermic circulatory arrest (DHCA for thoracic aortic operations is commonly managed with sodium bicarbonate (NaHCO 3 . The purpose of this study was to determine the relationships between total NaHCO 3 dose and the severity of metabolic acidosis, duration of mechanical ventilation, duration of vasoactive infusions, and Intensive Care Unit (ICU or hospital length of stay (LOS. Methods: In a single center, retrospective study, 87 consecutive elective thoracic aortic operations utilizing DHCA, were studied. Linear regression analysis was used to test for the relationships between the total NaHCO 3 dose administered through postoperative day 2, clinical variables, arterial blood gas values, and short-term clinical outcomes. Results: Seventy-five patients (86% received NaHCO 3 . Total NaHCO 3 dose averaged 136 ± 112 mEq (range: 0.0-535 mEq per patient. Total NaHCO 3 dose correlated with minimum pH (r = 0.41, P < 0.0001, minimum serum bicarbonate (r = −0.40, P < 0.001, maximum serum lactate (r = 0.46, P = 0.007, duration of metabolic acidosis (r = 0.33, P = 0.002, and maximum serum sodium concentrations (r = 0.29, P = 0.007. Postoperative hypernatremia was present in 67% of patients and peaked at 12 h following DHCA. Eight percent of patients had a serum sodium ≥ 150 mEq/L. Total NaHCO 3 dose did not correlate with anion gap, serum chloride, not the duration of mechanical ventilator support, vasoactive infusions, ICU or hospital LOS. Conclusion: Routine administration of NaHCO 3 was common for the management of metabolic acidosis after DHCA. Total dose of NaHCO 3 was a function of the severity and duration of metabolic acidosis. NaHCO 3 administration contributed to postoperative hypernatremia that was often severe. The total NaHCO 3 dose administered was unrelated to short-term clinical outcomes.

  6. Over length quantification of the multiaxial mechanical properties of the ascending, descending and abdominal aorta using Digital Image Correlation.

    Science.gov (United States)

    Peña, Juan A; Corral, Victoria; Martínez, Miguel A; Peña, Estefanía

    2018-01-01

    In this paper, we hypothesize that the biaxial mechanical properties of the aorta may be dependent on arterial location. To demonstrate any possible position-related difference, our study analyzed and compared the biaxial mechanical properties of the ascending thoracic aorta, descending thoracic aorta and infrarenal abdominal aorta stemming from the same porcine subjects, and reported values of constitutive parameters for well-known strain energy functions, showing how these mechanical properties are affected by location along the aorta. When comparing ascending thoracic aorta, descending thoracic aorta and infrarenal abdominal aorta, abdominal tissues were found to be stiffer and highly anisotropic. We found that the aorta changed from a more isotropic to a more anisotropic tissue and became progressively less compliant and stiffer with the distance to the heart. We observed substantial differences in the anisotropy parameter between aortic samples where abdominal samples were more anisotropic and nonlinear than the thoracic samples. The phenomenological model was not able to capture the passive biaxial properties of each specific porcine aorta over a wide range of biaxial deformations, showing the best prediction root mean square error ε=0.2621 for ascending thoracic samples and, especially, the worst for the infrarenal abdominal samples ε=0.3780. The micro-structured model with Bingham orientation density function was able to better predict biaxial deformations (ε=0.1372 for ascending thoracic aorta samples). The root mean square error of the micro-structural model and the micro-structured model with von Mises orientation density function were similar for all positions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Aortic ruptures in seat belt wearers.

    Science.gov (United States)

    Arajärvi, E; Santavirta, S; Tolonen, J

    1989-09-01

    Several investigations have indicated that rupture of the thoracic aorta is one of the leading causes of immediate death in victims of road traffic accidents. In Finland in 1983, 92% of front-seat passengers were seat belt wearers on highways and 82% in build-up areas. The mechanisms of rupture of the aorta have been intensively investigated, but the relationship between seat belt wearing and injury mechanisms leading to aortic rupture is still largely unknown. This study comprises 4169 fatally injured victims investigated by the Boards of Traffic Accident Investigation of Insurance Companies during the period 1972 to 1985. Chest injuries were recorded as the main cause of death in 1121 (26.9%) victims, 207 (5.0%) of those victims having worn a seat belt. Aortic ruptures were found at autopsy in 98 victims and the exact information of the location of the aortic tears was available in 68. For a control group, we analyzed 72 randomly chosen unbelted victims who had a fatal aortic rupture in similar accidents. The location of the aortic rupture in unbelted victims was more often in the ascending aorta, especially in drivers, whereas in seat belt wearers the distal descending aorta was statistically more often ruptured, especially in right-front passengers (p less than 0.05). The steering wheel predominated statistically as the part of the car estimated to have caused the injury in unbelted victims (37/72), and some interior part of the car was the most common cause of fatal thoracic impacts in seat belt wearers (48/68) (p less than 0.001). The mechanism of rupture of the aorta in the classic site just distal to the subclavian artery seems to be rapid deceleration, although complex body movements are also responsible in side impact collisions. The main mechanism leading to rupture of the ascending aorta seems to be severe blow to the bony thorax. This also often causes associated thoracic injuries, such as heart rupture and sternal fracture. Injuries in the ascending

  8. THE IMPACT OF DIAGNOSTIC DISCREPANCIES IN AORTIC DISSECTION MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Abdalla Hassan

    2016-01-01

    Full Text Available Aortic dissection is uncommon with high mortality rate if untreated. We report a challenging case of long segment aortic dissection in which the dissection type was very difficult to identify due to limitations of the available imaging studies. 66-year-old male presented to us with 3 days history of chest pain and difficulty breathing. He is known to be hypertensive. In the emergency room, patient has systolic blood pressure >190. Chest X-ray showed widening of mediastinum. CT angiography of chest and abdomen showed an acute dissection of the thoracic aorta extending from the mid ascending aorta to the infra-renal aorta suggestive of Stanford type A aortic dissection. Transthoracic and Trans-esophageal echocardiography revealed a partially calcified intimal flap in the distal portion of the arch and in the descending thoracic aorta suggestive of Stanford type B aortic dissection. Medical treatment started, and repeated CT angiography was obtained and it confirmed type B aortic dissection. One week after discharge, patient was readmitted with severe neck pain and difficulty breathing. CT chest without contrast showed grossly stable appearance of type A dissection consistent with the first CT angiography. Cardiothoracic surgery immediately reevaluated the situation and recommended surgical intervention.

  9. Management strategies for thoracic stent-graft repair of distal aortic arch lesions: is intentional subclavian artery occlusion a safe procedure?

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio; Salvatori, Filippo Maria; Pucci, Armando; Lucatelli, Pierleone; Rossi, Plinio; Passariello, Roberto [University of Rome La Sapienza, Department of Radiological Sciences, Rome (Italy); Dake, Michael D. [Stanford University School of Medicine, Department of Cardiothoracic Surgery Radiology, Stanford, CA (United States); Mazzesi, Giuseppe [University of Rome La Sapienza, Institute of Heart and Great Vessels, Rome (Italy)

    2009-10-15

    The aim of this retrospective analysis was to assess the clinical consequences after intentional left subclavian artery (LSA) occlusion. Thirty-seven patients, 27 type B dissection and 10 thoracic aneurysm, with short proximal neck (less than 2 cm) underwent endovascular treatment with intentional exclusion of LSA origin. No immediate complications occurred. Mean arterial pressure gradient, between right and left arms, ranged from 15 to 45 mmHg. After a mean follow-up of 43.70{+-}24.01 months, mild left arm symptoms secondary to flow reduction occurred in eight cases (21.6%) but only one required LSA transposition, after 8 months, for visual impairment. Type II endoleaks from excluded LSA occurred in 10 cases (27.0%): in seven patients, leaks were treated with coils and/or glue embolization; in one case, leak sealed spontaneously; one patient died before leak embolization could occur; one patient refused any further treatment. Intentional exclusion of the LSA may be justified when a longer proximal landing zone in the aortic arch is required. (orig.)

  10. [Loeys-Dietz syndrome (TGFβR2 mutation) in a 4-year-old child with thoracic aortic aneurysm].

    Science.gov (United States)

    De Potter, M-J; Edouard, T; Amadieu, R; Plaisancié, J; Julia, S; Hadeed, K; Hascoët, S; Acar, P; Dulac, Y

    2016-05-01

    Loeys-Dietz syndrome is a rare form of connective tissue disorder, whose clinical features can resemble those of Marfan syndrome, but with a more unpolished appearance. Recently brought out, this pathology remains little known; however, its consequences may be dramatic. We report on the case of a 4-year-old girl followed for a congenital hip dislocation, in which a systematic exam found increased cutaneous elasticity and a bifid uvula, suggesting a connective tissue disorder. Symptoms were unpolished, as the child's height was normal, without any positive cardiac, rheumatological, or ophthalmological family history. Cardiovascular tests found a thoracic aortic aneurysm at the Valsalva sinus (26mm, Z-score=+4.24). A genetic investigation found a TGFβR2 gene mutation, leading to the diagnosis of Loeys-Dietz syndrome type 2. Skeletal damage associated with bifid uvula and/or hypertelorism and an aneurysm of the ascending aorta should guide the genetic investigation to the search for TGF-β vasculopathy such as Loeys-Dietz syndrome. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  11. Successful outcome of descending necrotizing mediastinitis due to neck trauma

    International Nuclear Information System (INIS)

    Kurowski, K.; Matuszek, I.; Nunez, C. F. M.

    2011-01-01

    Descending necrotizing mediastinitis (DNM) is an uncommon form of mediastinitis that can rapidly progress to septicemia. The optimal surgical approach still remains controversial. In this paper we would like to present a case of descending necrotizing mediastinitis that was treated successfully by means of thoracic drainage through trans-thoracic approach. In our case DNM occurred as a complication of oropharyngeal abscesses and a complication of cervical spine trauma. (authors)

  12. Characterization of atherosclerotic disease in thoracic aorta: A 3D, multicontrast vessel wall imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Changwu [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China); Department of Radiology, The Second Clinical Medical College, Yangzhou University, Yangzhou (China); Qiao, Huiyu; He, Le [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China); Yuan, Chun [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China); Department of Radiology, University of Washington, Seattle, WA (United States); Chen, Huijun; Zhang, Qiang; Li, Rui [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China); Wang, Wei; Du, Fang [Department of Radiology, The Second Clinical Medical College, Yangzhou University, Yangzhou (China); Li, Cheng, E-mail: cjr.licheng@vip.163.com [Department of Radiology, Zhongda Hospital, Medical School of Southeast University, Nanjing (China); Zhao, Xihai, E-mail: xihaizhao@tsinghua.edu.cn [Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing (China)

    2016-11-15

    Purpose: To investigate the characteristics of plaque in the thoracic aorta using three dimensional multicontrast magnetic resonance imaging. Materials and methods: Elderly subjects (≥60 years) were recruited in this study. Thoracic aorta was imaged on a 3.0T MR scanner by acquiring multicontrast sequences. The plaque burden was evaluated by measuring lumen area, wall area, wall thickness, and normalized wall index. The presence or absence of plaque and intraplaque hemorrhage (IPH)/mural thrombus (MT) were identified. The characteristics of atherosclerosis among different thoracic aorta segments (AAO: ascending aorta; AOA: aortic arch, and DOA: descending aorta) were determined. Results: Of 66 recruited subjects (mean age 72.3 ± 6.2 years, 30 males), 55 (83.3%) had plaques in the thoracic aorta. The prevalence of plaque in AAO, AOA, and DAO was 5.4%, 72.7%, and 71.2%, respectively. In addition, 21.2% of subjects were found to have lesions with IPH/MT in the thoracic aorta. The prevalence of IPH/MT in segment of AAO, AOA and DAO was 0%, 13.6%, and 12.1%, respectively. The aortic wall showed the highest NWI in DAO (34.1% ± 4.8%), followed by AOA (31.2% ± 5%), and AAO (26.8% ± 3.3%) (p < 0.001). Conclusion: Three dimensional multicontrast MR imaging is capable of characterizing atherosclerotic plaques in the thoracic aorta. The findings of high prevalence of plaques and the presence of high risk plaques in the thoracic aorta suggest early screening for aortic vulnerable lesions in the elderly.

  13. Characterization of atherosclerotic disease in thoracic aorta: A 3D, multicontrast vessel wall imaging study

    International Nuclear Information System (INIS)

    Zhou, Changwu; Qiao, Huiyu; He, Le; Yuan, Chun; Chen, Huijun; Zhang, Qiang; Li, Rui; Wang, Wei; Du, Fang; Li, Cheng; Zhao, Xihai

    2016-01-01

    Purpose: To investigate the characteristics of plaque in the thoracic aorta using three dimensional multicontrast magnetic resonance imaging. Materials and methods: Elderly subjects (≥60 years) were recruited in this study. Thoracic aorta was imaged on a 3.0T MR scanner by acquiring multicontrast sequences. The plaque burden was evaluated by measuring lumen area, wall area, wall thickness, and normalized wall index. The presence or absence of plaque and intraplaque hemorrhage (IPH)/mural thrombus (MT) were identified. The characteristics of atherosclerosis among different thoracic aorta segments (AAO: ascending aorta; AOA: aortic arch, and DOA: descending aorta) were determined. Results: Of 66 recruited subjects (mean age 72.3 ± 6.2 years, 30 males), 55 (83.3%) had plaques in the thoracic aorta. The prevalence of plaque in AAO, AOA, and DAO was 5.4%, 72.7%, and 71.2%, respectively. In addition, 21.2% of subjects were found to have lesions with IPH/MT in the thoracic aorta. The prevalence of IPH/MT in segment of AAO, AOA and DAO was 0%, 13.6%, and 12.1%, respectively. The aortic wall showed the highest NWI in DAO (34.1% ± 4.8%), followed by AOA (31.2% ± 5%), and AAO (26.8% ± 3.3%) (p < 0.001). Conclusion: Three dimensional multicontrast MR imaging is capable of characterizing atherosclerotic plaques in the thoracic aorta. The findings of high prevalence of plaques and the presence of high risk plaques in the thoracic aorta suggest early screening for aortic vulnerable lesions in the elderly.

  14. Detection of thoracic vascular structures by electrical impedance tomography: a systematic assessment of prominence peak analysis of impedance changes.

    Science.gov (United States)

    Wodack, K H; Buehler, S; Nishimoto, S A; Graessler, M F; Behem, C R; Waldmann, A D; Mueller, B; Böhm, S H; Kaniusas, E; Thürk, F; Maerz, A; Trepte, C J C; Reuter, D A

    2018-02-28

    Electrical impedance tomography (EIT) is a non-invasive and radiation-free bedside monitoring technology, primarily used to monitor lung function. First experimental data shows that the descending aorta can be detected at different thoracic heights and might allow the assessment of central hemodynamics, i.e. stroke volume and pulse transit time. First, the feasibility of localizing small non-conductive objects within a saline phantom model was evaluated. Second, this result was utilized for the detection of the aorta by EIT in ten anesthetized pigs with comparison to thoracic computer tomography (CT). Two EIT belts were placed at different thoracic positions and a bolus of hypertonic saline (10 ml, 20%) was administered into the ascending aorta while EIT data were recorded. EIT images were reconstructed using the GREIT model, based on the individual's thoracic contours. The resulting EIT images were analyzed pixel by pixel to identify the aortic pixel, in which the bolus caused the highest transient impedance peak in time. In the phantom, small objects could be located at each position with a maximal deviation of 0.71 cm. In vivo, no significant differences between the aorta position measured by EIT and the anatomical aorta location were obtained for both measurement planes if the search was restricted to the dorsal thoracic region of interest (ROIs). It is possible to detect the descending aorta at different thoracic levels by EIT using an intra-aortic bolus of hypertonic saline. No significant differences in the position of the descending aorta on EIT images compared to CT images were obtained for both EIT belts.

  15. Pericardial and thoracic peri-aortic adipose tissues contribute to systemic inflammation and calcified coronary atherosclerosis independent of body fat composition, anthropometric measures and traditional cardiovascular risks

    International Nuclear Information System (INIS)

    Yun, Chun-Ho; Lin, Tin-Yu; Wu, Yih-Jer; Liu, Chuan-Chuan; Kuo, Jen-Yuan; Yeh, Hung-I.; Yang, Fei-Shih; Chen, Su-Chiu; Hou, Charles Jia-Yin; Bezerra, Hiram G.; Hung, Chung-Lieh; Cury, Ricardo C.

    2012-01-01

    Background: Coronary atherosclerosis has traditionally been proposed to be associated with several cardiovascular risk factors and anthropometric measures. However, clinical data regarding the independent value of visceral adipose tissue in addition to such traditional predictors remains obscure. Materials and methods: We subsequently studied 719 subjects (age: 48.1 ± 8.3 years, 25% females) who underwent multidetector computed tomography (MDCT) for coronary calcium score (CCS) quantification. Baseline demographic data and anthropometric measures were taken with simultaneous body fat composition estimated. Visceral adipose tissue of pericardial and thoracic peri-aortic fat was quantified by MDCT using TeraRecon Aquarius workstation (San Mateo, CA). Traditional cardiovascular risk stratification was calculated by metabolic (NCEP ATP III) and Framingham (FRS) scores and high-sensitivity CRP (Hs-CRP) was taken to represent systemic inflammation. The independent value of visceral adipose tissue to systemic inflammation and CCS was assessed by utilizing multivariable regression analysis. Results: Of all subjects enrolled in this study, the mean values for pericardial and peri-aortic adipose tissue were 74.23 ± 27.51 and 7.23 ± 3.69 ml, respectively. Higher visceral fat quartile groups were associated with graded increase of risks for cardiovascular diseases. Both adipose burdens strongly correlated with anthropometric measures including waist circumference, body weight and body mass index (all p < 0.001). In addition, both visceral amount correlates well with ATP and FRS scores, all lipid profiles and systemic inflammation marker in terms of Hs-CRP (all p < 0.001). After adjustment for baseline variables, both visceral fat were independently related to Hs-CRP levels (all p < 0.05), but only pericardial fat exerted independent role in coronary calcium deposit. Conclusion: Both visceral adipose tissues strongly correlated with systemic inflammation beyond traditional

  16. Significance and function of different spinal collateral compartments following thoracic aortic surgery: immediate versus long-term flow compensation.

    Science.gov (United States)

    Meffert, Philipp; Bischoff, Moritz S; Brenner, Robert; Siepe, Matthias; Beyersdorf, Friedhelm; Kari, Fabian A

    2014-05-01

    Iatrogenic paraplegia has been accompanying cardiovascular surgery since its beginning. As a result, surgeons have been developing many theories about the exact mechanisms of this devastating complication. Thus, the impact of single arteries that contribute to the spinal perfusion is one of the most discussed subjects in modern surgery. The subsequent decision of reattachment or the permanent disconnection of these intercostal arteries divides the surgical community. On the one hand, the anatomical or vascular approach pleads for the immediate reimplantation to reconstruct the anatomical situation. On the other hand, the decision of the permanent disconnection aims at avoiding stealing phenomenon away from the spinal vascular network. This spinal collateral network can be described as consisting of three components-the intraspinal and two paraspinal compartments-that feed the nutrient arteries of the spinal cord. The exact functional impact of the different compartments of the collateral network remains poorly understood. In this review, the function of the intraspinal compartment in the context of collateral network principle as an immediate emergency backup system is described. The exact structure and architectural principles of the intraspinal compartment are described. The critical parameters with regard to the risk of postoperative spinal cord ischaemia are the number of anterior radiculomedullary arteries (ARMAs) and the distance between them in relation to the longitudinal extent of aortic disease. The paraspinal network as a sleeping reserve is proposed as the long-term backup system. This sleeping reserve has to be activated by arteriogenic stimuli. These are presented briefly, and prior findings regarding arteriogenesis are discussed in the light of the collateral network concept. Finally, the role of preoperative visualization of the ARMAs in order to evaluate the risk of postoperative paraplegia is emphasized.

  17. Aortic arch/elephant trunk procedure with Sienna(TM) graft and endovascular stenting of thoraco-abdominal aorta for treatment of complex chronic dissection.

    Science.gov (United States)

    Wong, Randolph H L; Baghai, Max; Yu, Simon C H; Underwood, Malcolm J

    2013-05-01

    Aneurismal dilatation of the remaining thoracic aorta after ascending aortic interposition grafting for type 'A' aortic dissection is not uncommon. For such complex cases, one treatment option is total arch replacement and elephant trunk procedure with the Sienna(TM) collared graft (Vascutek, Inchinnan, UK) technique followed by a staged thoracic endovascular aortic repair (TEVAR). The video illustrates our technique in a 56-year-old man with an extensive aortic arch and descending thoracic aortic dissecting aneurysm. For the 'open' procedure femoral arterial and venous cannulation was used along with systemic cooling and circulatory arrest at 22 °C. Upon circulatory arrest, the aortic arch was incised and antegrade cerebral perfusion achieved via selective cannulation to the right brachiocephalic and left common carotid artery, keeping flow rates at 10-15 mL/kg/min and perfusion pressure at 50-60 mmHg. Arch replacement with an elephant trunk component was then performed and after completion of the distal aortic anastomosis antegrade perfusion via a side-arm in the graft was started and the operation completed using a variation of the 'sequential' clamping technique to maximize cerebral perfusion. The second endovascular stage was performed two weeks after discharge. Two covered stents were landing from the elephant trunk to the distal descending thoracic aorta, to secure the distal landing a bare stent of was placed to cover the aorta just distal to the origin of the celiac axis. The left subclavian artery was embolised with fibre coils. Post TEVAR angiogram showed no endoleak Although re-operative total arch replacement and elephant trunk procedure and subsequent TEVAR remained a challenging procedure, we believe excellent surgical outcome can be achieved with carefully planned operative strategy.

  18. Aortic valve replacement for aortic stenosis caused by alkaptonuria.

    Science.gov (United States)

    Hiroyoshi, Junko; Saito, Aya; Panthee, Nirmal; Imai, Yasushi; Kawashima, Dai; Motomura, Noboru; Ono, Minoru

    2013-03-01

    We report a case of aortic stenosis associated with ochronosis in a 70-year-old man who underwent biologic aortic valve replacement. Intraoperative findings included ochronosis of a severely calcified pigmented aortic valve along with pigmentation of the intima of the aorta. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. The Complement C3a-C3aR Axis Promotes Development of Thoracic Aortic Dissection via Regulation of MMP2 Expression.

    Science.gov (United States)

    Ren, Weihong; Liu, Yan; Wang, Xuerui; Piao, Chunmei; Ma, Youcai; Qiu, Shulan; Jia, Lixin; Chen, Boya; Wang, Yuan; Jiang, Wenjian; Zheng, Shuai; Liu, Chang; Dai, Nan; Lan, Feng; Zhang, Hongjia; Song, Wen-Chao; Du, Jie

    2018-03-01

    Thoracic aortic dissection (TAD), once ruptured, is devastating to patients, and no effective pharmaceutical therapy is available. Anaphylatoxins released by complement activation are involved in a variety of diseases. However, the role of the complement system in TAD is unknown. We found that plasma levels of C3a, C4a, and C5a were significantly increased in patients with TAD. Elevated circulating C3a levels were also detected in the developmental process of mouse TAD, which was induced by β-aminopropionitrile monofumarate (BAPN) treatment, with enhanced expression of C1q and properdin in mouse dissected aortas. These findings indicated activation of classical and alternative complement pathways. Further, expression of C3aR was obviously increased in smooth muscle cells of human and mouse dissected aortas, and knockout of C3aR notably inhibited BAPN-induced formation and rupture of TAD in mice. C3aR antagonist administered pre- and post-BAPN treatment attenuated the development of TAD. We found that C3aR knockout decreased matrix metalloproteinase 2 (MMP2) expression in BAPN-treated mice. Additionally, recombinant C3a stimulation enhanced MMP2 expression and activation in smooth muscle cells that were subjected to mechanical stretch. Finally, we generated MMP2-knockdown mice by in vivo MMP2 short hairpin RNA delivery using recombinant adeno-associated virus and found that MMP2 deficiency significantly reduced the formation of TAD. Therefore, our study suggests that the C3a - C3aR axis contributes to the development of TAD via regulation of MMP2 expression. Targeting the C3a-C3aR axis may represent a strategy for inhibiting the formation of TAD. Copyright © 2018 by The American Association of Immunologists, Inc.

  20. Endovascular implantation of stent-grafts in the thoracic aorta - mid-term results of a prospective controlled study

    International Nuclear Information System (INIS)

    Duda, S.H.; Pusich, B.; Tepe, G.; Pereira, P.; Feuls, R.; Claussen, C.D.; Raygrotzki, S.; Aebert, H.; Ziemer, G.; Uckmann, F.P.

    2002-01-01

    Purpose: To evaluate the effectiveness and safety of endovascular treatment of various descending thoracic aortic pathologies with covered stent-grafts as an alternative to open surgery. Methods: Among 16 patients (5 type B dissections, 5 contained ruptures, 3 aneurysms of the descending aorta, 1 thoraco-abdominal aneurysm, 1 mural thrombosis, 1 patch aneurysm) treated between November 1997 and November 2000, eight patients received Talent TM stent-grafts and another 8 patients underwent a Gore-TAG TM stent-graft implantation. A clinical follow-up and control CT scans were obtained after the procedure and then at six-month intervals. Results: Deployment of the stent-grafts was technically successful in all cases. Sufficient aortic reconstruction was achieved in all but one patient who needed surgical treatment. One patient died two days after the procedure from aortic rupture due to retrograde type A dissection. Another patient died 19 months after the procedure from an unknown cause. There was no occurrence of distal embolization, paralysis or infection. During follow-up, all patients remained free from recurrence or late complications of their disease. Conclusion: Endoluminal treatment of thoracic aortic pathologies with covered stent-grafts appears to be a safe and feasible method with at least mid-term efficacy. (orig.) [de

  1. Current role of endovascular therapy in Marfan patients with previous aortic surgery

    Directory of Open Access Journals (Sweden)

    Ibrahim Akin

    2008-02-01

    Full Text Available Ibrahim Akin, Stephan Kische, Tim C Rehders, Tushar Chatterjee, Henrik Schneider, Thomas Körber, Christoph A Nienaber, Hüseyin InceDepartment of Medicine, Division of Cardiology at the University Hospital Rostock, Rostock School of Medicine, Ernst-Heydemann-Str. 6, 18057 Rostock, GermanyAbstract: The Marfan syndrome is a heritable disorder of the connective tissue which affects the cardiovascular, ocular, and skeletal system. The cardiovascular manifestation with aortic root dilatation, aortic valve regurgitation, and aortic dissection has a prevalence of 60% to 90% and determines the premature death of these patients. Thirty-four percent of the patients with Marfan syndrome will have serious cardiovascular complications requiring surgery in the first 10 years after diagnosis. Before aortic surgery became available, the majority of the patients died by the age of 32 years. Introduction in the aortic surgery techniques caused an increase of the 10 year survival rate up to 97%. The purpose of this article is to give an overview about the feasibility and outcome of stent-graft placement in the descending thoracic aorta in Marfan patients with previous aortic surgery.Keywords: Marfan syndrome, aortic dissection, root replacement, stent-graft, previous aortic surgery

  2. Aortic Branch Artery Pseudoaneurysms Associated with Intramural Hematoma: When and How to Do Endovascular Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Carlo; Rossi, Umberto G., E-mail: urossi76@hotmail.com; Seitun, Sara [IRCCS San Martino University Hospital, IST, National Institute for Cancer Research, Department of Radiology and Interventional Radiology (Italy); Scarano, Flavio; Passerone, Giancarlo [IRCCS San Martino University Hospital, IST, National Institute for Cancer Research, Department of Cardiac Surgery (Italy); Williams, David M. [University of Michigan Medical Center, Department of Radiology, Division of Vascular and Interventional Radiology (United States)

    2013-04-15

    To describe when and how to perform endovascular embolization of aortic branch artery pseudoaneurysms associated with type A and type B intramural hematoma (IMH) involving the descending thoracic and abdominal aorta (DeBakey I and III) that increased significantly in size during follow-up. Sixty-one patients (39 men; mean {+-} standard deviation age 66.1 {+-} 11.2 years) with acute IMH undergoing at least two multidetector computed tomographic examinations during follow-up for 12 months or longer were enrolled. Overall, 48 patients (31 men, age 65.9 {+-} 11.5) had type A and type B IMH involving the descending thoracic and abdominal aorta (DeBakey I and III). Among the 48 patients, 26 (54 %; 17 men, aged 64.3 {+-} 11.4 years) had 71 aortic branch artery pseudoaneurysms. Overall, during a mean follow-up of 22.1 {+-} 9.5 months (range 12-42 months), 31 (44 %) pseudoaneurysms disappeared; 22 (31 %) decreased in size; two (3 %) remained stable; and 16 (22 %) increased in size. Among the 16 pseudoaneurysms with increasing size, five of these (three intercostal arteries, one combined intercostobronchial/intercostal arteries, one renal artery), present in five symptomatic patients, had a significant increase in size (thickness >10 mm; width and length >20 mm). These five patients underwent endovascular embolization with coils and/or Amplatzer Vascular Plug. In all patients, complete thrombosis and exclusion of aortic pseudoaneurysm and relief of back pain were achieved. Aortic branch artery pseudoaneurysms associated with type A and type B IMH involving the descending thoracic and abdominal aorta (DeBakey I and III) may be considered relatively benign lesions. However, a small number may grow in size or extend longitudinally with clinical symptoms during follow-up, and in these cases, endovascular embolization can be an effective and safe procedure.

  3. Elephant trunk in a small-calibre true lumen for chronic aortic dissection: cause of haemolytic anaemia?

    Science.gov (United States)

    Araki, Haruna; Kitamura, Tadashi; Horai, Tetsuya; Shibata, Ko; Miyaji, Kagami

    2014-12-01

    The elephant trunk technique for aortic dissection is useful for reducing false lumen pressure; however, a folded vascular prosthesis inside the aorta can cause haemolysis. The purpose of this study was to investigate whether an elephant trunk in a small-calibre lumen can cause haemolysis. Inpatient and outpatient records were retrospectively reviewed. Two cases of haemolytic anaemia after aortic surgery using the elephant trunk technique were identified from 2011 to 2013. A 64-year-old man, who underwent graft replacement of the ascending aorta for acute Stanford type A aortic dissection, presented with enlargement of the chronic dissection of the descending aorta and moderate aortic regurgitation. A two-stage surgery was scheduled. Total arch replacement with an elephant trunk in the true lumen and concomitant aortic valve replacement were performed. Postoperatively, he developed severe haemolytic anaemia because of the folded elephant trunk. The anaemia improved after the second surgery, including graft replacement of the descending aorta. Similarly, a 61-year-old man, who underwent total arch replacement for acute Stanford type A aortic dissection, presented with enlargement of the chronic dissection of the descending aorta. Graft replacement of the descending aorta with an elephant trunk inserted into the true lumen was performed. The patient postoperatively developed haemolytic anaemia because of the folded elephant trunk, which improved after additional stent grafting into the elephant trunk. A folded elephant trunk in a small-calibre lumen can cause haemolysis. Therefore, inserting an elephant trunk in a small-calibre true lumen during surgery for chronic aortic dissection should be avoided. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  4. Propagation of aortic dissection and visceral artery compromise. Three-dimensional analysis on CT angiography

    International Nuclear Information System (INIS)

    Minamiguchi, Hiroki

    2003-01-01

    The purpose of this study was to clarify the patterns of the propagation of aortic dissection with quantitative data from CT angiography and to verify the relationship between the propagation of aortic dissection and visceral artery compromise. The subjects were 67 cases (48 men, 19 women) with acute and subacute aortic dissection extending from the descending thoracic aorta to the aortic bifurcation. The mean age is 56.5±12.3 years old (range 34 to 80 years). Eight axial levels of the trunk of right pulmonary artery, left inferior pulmonary vein, coronary sinus, celiac axis, the orifice of superior mesenteric artery (SMA), the orifice of right real artery, the orifice of left renal artery and the orifice of inferior mesenteric artery were submitted to investigate the propagation of aortic dissection. The true lumen central angle was calculated in each level. The axial distance, branch angle difference and true distance between SMA and bilateral renal arteries were calculated. The trajectory of aortic dissection propagation from descending thoracic aorta to aortic bifurcation could be divided into two types of linear dissection type (n=41) and spiral dissection type (n=26). The latter were further subdivided into clockwise rotation type (n=14) and counter-clockwise rotation type (n=12). Younger age was significantly associated with the spiral dissection type as compared to older age (p=0.030). The spiral dissection type propagation pattern was found predominantly from the descending thoracic aorta to celiac axis, while at more distal levels linear type dissection was more common. The blood flow of SMA and celiac axis came from the true lumen or both lumens in all cases but single case from false lumen. The incidence (19.4%) of the right renal blood flow supplied from false lumen was lower than that (37.3%) of the left one supplied from false lumen. The shorter distance and the less angle difference between SMA and right renal artery than between SMA and left renal

  5. Retrograde Embolization of the Left Vertebral Artery in a Type II Endoleak After Endovascular Treatment of Aortic Thoracic Rupture: Technical Note

    International Nuclear Information System (INIS)

    Rabellino, Martin; Garcia Nielsen, L.; Baldi, S.; Zander, T.; Arnaiz, L.; Llorens, R.; Zerolo, I.; Maynar, M.

    2009-01-01

    Endoleak is a frequent complication after endovascular repair of aortic rupture. We describe the case of a female patient with traumatic aortic injury, treated with endograft, who developed a type II endoleak through the left subclavian and vertebral arteries. Both arteries originated independently from the aortic arch, and were managed with coil embolization of each vessel. We also report our experience with treating the left vertebral artery by placing a microcatheter through the right vertebral one.

  6. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography; Avaliacao dos diametros normais da aorta toracica e abdominal pela tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, Claudio Luiz

    1995-07-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  7. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography; Avaliacao dos diametros normais da aorta toracica e abdominal pela tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Lucarelli, Claudio Luiz

    1995-07-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  8. A Case of an Aortic Abscess around the Elephant Trunk.

    Science.gov (United States)

    Fujii, Takeshiro; Kawasaki, Muneyasu; Katayanagi, Tomoyuki; Okuma, Shinnosuke; Masuhara, Hiroshi; Shiono, Noritsugu; Watanabe, Yoshinori

    2015-01-01

    A 52-year-old male patient with a history of total arch replacement using the elephant trunk technique for acute aortic dissection 4 years before visited our hospital with the chief complaint of persistent fever. Chest computed tomography (CT) suggested prosthetic vascular graft infection, which was treated surgically after chemotherapy. The first surgery consisted of debridement of an abscess around the vascular graft and in the aorta around the elephant trunk, and thoracic descending aorta replacement and vacuum-assisted closure (VAC) in view of the risk of bleeding from the peripheral region of the elephant trunk. One week later, omental filling was performed as the second step. This is a very rare case of aortic abscess around the elephant trunk that could successfully be managed by graft-conserving treatment.

  9. Endovascular Treatment of Various Aortic Pathologies: Review of the Latest Data and Technologies.

    Science.gov (United States)

    Maeda, Koji; Ohki, Takao; Kanaoka, Yuji

    2018-06-01

    The technologies and innovations applicable to endovascular treatment for complex aortic pathologies have progressed rapidly over the last two decades. Although the initial outcomes of an endovascular aortic repair have been excellent, as long-term data became available, complications including endoleaks, endograft migration, and endograft infection have become apparent and are of concern. Previously, the indication for endovascular therapy was restricted to descending thoracic aortic aneurysms and abdominal aortic aneurysms. However, its indication has expanded along with the improvement of techniques and devices, and currently, it has become possible to treat pararenal aortic aneurysms and Crawford type 4 thoracoabdominal aortic aneurysm (TAAA) using the off-the-shelf devices. Additionally, custom-made devices allow for the treatment of arch or more extensive TAAAs. Endovascular treatment is applied not only to aneurysms but also to acute/chronic dissections. However, long-term outcomes are still unclear. This article provides an overview of available devices and the results of endovascular treatment for various aortic pathologies.

  10. Magnetic resonance imaging 4-D flow-based analysis of aortic hemodynamics in Turner syndrome.

    Science.gov (United States)

    Arnold, Raoul; Neu, Marie; Hirtler, Daniel; Gimpel, Charlotte; Markl, Michael; Geiger, Julia

    2017-04-01

    Cardiovascular surveillance is important in Turner syndrome because of the increased risk of aortic dilation and dissection with consecutively increased mortality. To compare 4-D flow MRI for the characterization of aortic 3-D flow patterns, dimensions and vessel wall parameters in pediatric patients with Turner syndrome and age-matched controls. We performed 4-D flow MRI measuring in vivo 3-D blood flow with coverage of the thoracic aorta in 25 patients with Turner syndrome and in 16 female healthy controls (age mean ± standard deviation were 16 ± 5 years and 17 ± 4 years, respectively). Blood flow was visualized by time-resolved 3-D path lines. Visual grading of aortic flow in terms of helices and vortices was performed by two independent observers. Quantitative analysis included measurement of aortic diameters, quantification of peak systolic wall shear stress, pulsatility index and oscillatory shear index at eight defined sites. Patients with Turner syndrome had significantly larger aortic diameters normalized to BSA, increased vortices in the ascending aorta and elevated helix flow in the ascending and descending aorta compared to controls (all PTurner patients compared to controls (p=0.02, p=0.002 and p=0.01 respectively). Four-dimensional flow MRI provides new insights into the altered aortic hemodynamics and wall shear stress that could have an impact on the development of aortic dissections.

  11. Differences in the Thoracic Aorta by Region and Sex in a Murine Model of Marfan Syndrome

    Directory of Open Access Journals (Sweden)

    Francesc Jiménez-Altayó

    2017-11-01

    Full Text Available Marfan syndrome (MFS is a hereditary disorder of the connective tissue that causes life-threatening aortic aneurysm, which initiates at the aortic root and can progress into the ascending portion. However, analysis of ascending aorta reactivity in animal models of MFS has remained elusive. Epidemiologic evidence suggests that although MFS is equally prevalent in men and women, men are at a higher risk of aortic complications than non-pregnant women. Nevertheless, there is no experimental evidence to support this hypothesis. The aim of this study was to explore whether there are regional and sex differences in the thoracic aorta function of mice heterozygous for the fibrillin 1 (Fbn1 allele encoding a missense mutation (Fbn1C1039G/+, the most common class of mutation in MFS. Ascending and descending thoracic aorta reactivity was evaluated by wire myography. Ascending aorta mRNA and protein levels, and elastic fiber integrity were assessed by qRT-PCR, Western blotting, and Verhoeff-Van Gieson histological staining, respectively. MFS differently altered reactivity in the ascending and descending thoracic aorta by either increasing or decreasing phenylephrine contractions, respectively. When mice were separated by sex, contractions to phenylephrine increased progressively from 3 to 6 months of age in MFS ascending aortas of males, whereas contractions in females were unchanged. Endothelium-dependent relaxation was unaltered in the MFS ascending aorta of either sex; an effect related to augmented endothelium-dependent hyperpolarization-type dilations. In MFS males, the non-selective cyclooxygenase (COX inhibitor indomethacin prevented the MFS-induced enhancement of phenylephrine contractions linked to increased COX-2 expression. In MFS mice of both sexes, the non-selective nitric oxide synthase inhibitor L-NAME revealed negative feedback of nitric oxide on phenylephrine contractions, which was associated with upregulation of eNOS in females. Finally

  12. Differences in the Thoracic Aorta by Region and Sex in a Murine Model of Marfan Syndrome

    Science.gov (United States)

    Jiménez-Altayó, Francesc; Siegert, Anna-Maria; Bonorino, Fabio; Meirelles, Thayna; Barberà, Laura; Dantas, Ana P.; Vila, Elisabet; Egea, Gustavo

    2017-01-01

    Marfan syndrome (MFS) is a hereditary disorder of the connective tissue that causes life-threatening aortic aneurysm, which initiates at the aortic root and can progress into the ascending portion. However, analysis of ascending aorta reactivity in animal models of MFS has remained elusive. Epidemiologic evidence suggests that although MFS is equally prevalent in men and women, men are at a higher risk of aortic complications than non-pregnant women. Nevertheless, there is no experimental evidence to support this hypothesis. The aim of this study was to explore whether there are regional and sex differences in the thoracic aorta function of mice heterozygous for the fibrillin 1 (Fbn1) allele encoding a missense mutation (Fbn1C1039G/+), the most common class of mutation in MFS. Ascending and descending thoracic aorta reactivity was evaluated by wire myography. Ascending aorta mRNA and protein levels, and elastic fiber integrity were assessed by qRT-PCR, Western blotting, and Verhoeff-Van Gieson histological staining, respectively. MFS differently altered reactivity in the ascending and descending thoracic aorta by either increasing or decreasing phenylephrine contractions, respectively. When mice were separated by sex, contractions to phenylephrine increased progressively from 3 to 6 months of age in MFS ascending aortas of males, whereas contractions in females were unchanged. Endothelium-dependent relaxation was unaltered in the MFS ascending aorta of either sex; an effect related to augmented endothelium-dependent hyperpolarization-type dilations. In MFS males, the non-selective cyclooxygenase (COX) inhibitor indomethacin prevented the MFS-induced enhancement of phenylephrine contractions linked to increased COX-2 expression. In MFS mice of both sexes, the non-selective nitric oxide synthase inhibitor L-NAME revealed negative feedback of nitric oxide on phenylephrine contractions, which was associated with upregulation of eNOS in females. Finally, MFS ascending

  13. Reference Values for Cardiac and Aortic Magnetic Resonance Imaging in Healthy, Young Caucasian Adults.

    Science.gov (United States)

    Eikendal, Anouk L M; Bots, Michiel L; Haaring, Cees; Saam, Tobias; van der Geest, Rob J; Westenberg, Jos J M; den Ruijter, Hester M; Hoefer, Imo E; Leiner, Tim

    2016-01-01

    Reference values for morphological and functional parameters of the cardiovascular system in early life are relevant since they may help to identify young adults who fall outside the physiological range of arterial and cardiac ageing. This study provides age and sex specific reference values for aortic wall characteristics, cardiac function parameters and aortic pulse wave velocity (PWV) in a population-based sample of healthy, young adults using magnetic resonance (MR) imaging. In 131 randomly selected healthy, young adults aged between 25 and 35 years (mean age 31.8 years, 63 men) of the general-population based Atherosclerosis-Monitoring-and-Biomarker-measurements-In-The-YOuNg (AMBITYON) study, descending thoracic aortic dimensions and wall thickness, thoracic aortic PWV and cardiac function parameters were measured using a 3.0T MR-system. Age and sex specific reference values were generated using dedicated software. Differences in reference values between two age groups (25-30 and 30-35 years) and both sexes were tested. Aortic diameters and areas were higher in the older age group (all page or sex effect. This study provides age and sex specific reference values for cardiovascular MR parameters in healthy, young Caucasian adults. These may aid in MR guided pre-clinical identification of young adults who fall outside the physiological range of arterial and cardiac ageing.

  14. Unicuspid aortic valve disease: a magnetic resonance imaging study

    International Nuclear Information System (INIS)

    Debl, K.; Buchner, S.; Heinicke, N.; Riegger, G.; Luchner, A.; Djavidani, B.; Poschenrieder, F.; Feuerbach, S.; Schmid, C.; Kobuch, R.

    2008-01-01

    Purpose: congenitally malformed aortic valves are a common finding in adults with aortic valve disease. Most of these patients have bicuspid aortic valve disease. Unicuspid aortic valve disease (UAV) is rare. The aim of our study was to describe valve morphology and the dimensions of the proximal aorta in a cohort of 12 patients with UAV in comparison to tricuspid aortic valve disease (TAV) using magnetic resonance imaging (MRI). Materials and methods/results: MRI studies were performed on a 1.5 T scanner in a total of 288 consecutive patients with aortic valve disease. 12 aortic valves were retrospectively classified as UAV. Annulus areas and dimensions of the thoracic aorta were retrospectively compared to a cohort of 103 patients with TAV. In UAV, valve morphology was unicuspid unicommissural with a posterior commissure in all patients. Mean annulus areas and mean diameters of the ascending aorta were significantly greater in UAV compared to TAV (12.6 ± 4.7 cm 2 vs. 8.7 ± 2.3 cm 2 , p < 0.01 and 4.6 ± 0.7 cm vs. 3.6 ± 0.5 cm, p < 0.0001, respectively), while no differences were observed in the mean diameters of the aortic arch (2.3 ± 0.6 cm vs. 2.3 ± 0.4 cm, p = 0.69). The diameters of the descending aorta were slightly smaller in UAV compared to TAV (2.2 ± 0.5 cm vs. 2.6 ± 0.3 cm, p < 0.05). (orig.)

  15. Unicuspid aortic valve disease: a magnetic resonance imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Debl, K.; Buchner, S.; Heinicke, N.; Riegger, G.; Luchner, A. [Klinik und Poliklinik fuer Innere Medizin II, Universitaetsklinikum Regensburg (Germany); Djavidani, B.; Poschenrieder, F.; Feuerbach, S. [Inst. fuer Roentgendiagnostik, Universitaetsklinikum Regensburg (Germany); Schmid, C.; Kobuch, R. [Klinik und Poliklinik fuer Herz-, Thorax- und herznahe Gefaesschirurgie, Universitaetsklinikum Regensburg (Germany)

    2008-11-15

    Purpose: congenitally malformed aortic valves are a common finding in adults with aortic valve disease. Most of these patients have bicuspid aortic valve disease. Unicuspid aortic valve disease (UAV) is rare. The aim of our study was to describe valve morphology and the dimensions of the proximal aorta in a cohort of 12 patients with UAV in comparison to tricuspid aortic valve disease (TAV) using magnetic resonance imaging (MRI). Materials and methods/results: MRI studies were performed on a 1.5 T scanner in a total of 288 consecutive patients with aortic valve disease. 12 aortic valves were retrospectively classified as UAV. Annulus areas and dimensions of the thoracic aorta were retrospectively compared to a cohort of 103 patients with TAV. In UAV, valve morphology was unicuspid unicommissural with a posterior commissure in all patients. Mean annulus areas and mean diameters of the ascending aorta were significantly greater in UAV compared to TAV (12.6 {+-} 4.7 cm{sup 2} vs. 8.7 {+-} 2.3 cm{sup 2}, p < 0.01 and 4.6 {+-} 0.7 cm vs. 3.6 {+-} 0.5 cm, p < 0.0001, respectively), while no differences were observed in the mean diameters of the aortic arch (2.3 {+-} 0.6 cm vs. 2.3 {+-} 0.4 cm, p = 0.69). The diameters of the descending aorta were slightly smaller in UAV compared to TAV (2.2 {+-} 0.5 cm vs. 2.6 {+-} 0.3 cm, p < 0.05). (orig.)

  16. Re-interventions on the thoracic and thoracoabdominal aorta in patients with Marfan syndrome.

    Science.gov (United States)

    Schoenhoff, Florian S; Carrel, Thierry P

    2017-11-01

    The advent of multi-gene panel genetic testing and the discovery of new syndromic and non-syndromic forms of connective tissue disorders have established thoracic aortic aneurysms as a genetically mediated disease. Surgical results in patients with Marfan syndrome (MFS) provide an important benchmark for this patient population. Prophylactic aortic root surgery prevents acute dissection and has contributed to the improved survival of MFS patients. In the majority of patients, re-interventions are driven by a history of dissection. Patients undergoing elective root repair have a low risk for re-interventions on the root itself. Experienced centers have results after valve-sparing procedures at 10 years comparable with those seen after a modified Bentall procedure. In patients where only the ascending aorta was replaced during the initial surgery, re-intervention rates are high as the root continues to dilate. The fate of the aortic arch in MFS patients presenting with dissection is strongly correlated with the extent of the initial surgery. Not replacing the entire ascending aorta and proximal aortic arch results in a high rate of re-interventions. Nevertheless, the additional burden of replacing the entire aortic arch during emergent proximal repair is not very well defined and makes comparisons with patients undergoing elective arch replacement difficult. Interestingly, replacing the entire aortic arch during initial surgery for acute dissection does not protect from re-interventions on downstream aortic segments. MFS patients suffering from type B dissection have a high risk for re-interventions ultimately leading up to replacement of the entire thoracoabdominal aorta even if the dissection was deemed uncomplicated by conventional criteria. While current guidelines do not recommend the implantation of stent grafts in MFS patients, implantation of a frozen-elephant-trunk to create a stable proximal landing zone for future endovascular or open procedures has

  17. Spinal cord ischemia after simultaneous and sequential treatment of multilevel aortic disease.

    Science.gov (United States)

    Piffaretti, Gabriele; Bonardelli, Stefano; Bellosta, Raffaello; Mariscalco, Giovanni; Lomazzi, Chiara; Tolenaar, Jip L; Zanotti, Camilla; Guadrini, Cristina; Sarcina, Antonio; Castelli, Patrizio; Trimarchi, Santi

    2014-10-01

    The aim of the present study is to report a risk analysis for spinal cord injury in a recent cohort of patients with simultaneous and sequential treatment of multilevel aortic disease. We performed a multicenter study with a retrospective data analysis. Simultaneous treatment refers to descending thoracic and infrarenal aortic lesions treated during the same operation, and sequential treatment refers to separate operations. All descending replacements were managed with endovascular repair. Of 4320 patients, multilevel aortic disease was detected in 77 (1.8%). Simultaneous repair was performed in 32 patients (41.5%), and a sequential repair was performed in 45 patients (58.4%). Postoperative spinal cord injury developed in 6 patients (7.8%). At multivariable analysis, the distance of the distal aortic neck from the celiac trunk was the only independent predictor of postoperative spinal cord injury (odds ratio, 0.75; 95% confidence interval, 0.56-0.99; P=.046); open surgical repair of the abdominal aortic disease was associated with a higher risk of spinal cord injury but did not reach statistical significance (odds ratio, 0.16; 95% confidence interval, 0.02-1.06; P=.057). Actuarial survival estimates at 1, 2, and 5 years after the procedure were 80%±5%, 68%±6%, and 63%±7%, respectively. Spinal cord injury did not impair survival (P=.885). In our experience, the risk of spinal cord injury is still substantial at 8% in patients with multilevel aortic disease. The distance of the distal landing zone from the celiac trunk is a significant predictor of spinal cord ischemia. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  18. Noninvasive radiodiagnosis of aneurysms of the thoracic aorta

    International Nuclear Information System (INIS)

    Todua, F.I.; Petsko, A.P.; Arablinskij, A.V.; Kazanchyan, P.O.; Nikitaev, N.S.; Sultanaliev, T.A.

    1990-01-01

    The paper is concerned with analysis of the results of X-ray investigation of 45 patients with aneurysms of the distal part of the arch and descending part of the thoracic aorta. X-ray investigation helped to establish correct diagnosis of aneurysm of the aorta in 42 of 45 patients (93.3 %) on the basis of the detection of intense additional shadow formation in left pulmonary field, unseparable from the aortic shadow. The use of a new method of ultrasound diagnosis-duplex scanning-made it possible to establish the presence of aneurysm and to determine its sizes as well as to visualize the relation of the left subclavicular artery to aneurysm in 17 of 21 patients. CT-semiotics of aneurysms of the descending part of the thoracic aorta consisted in its dilatation over 3.5 cm, wall calcification, thrombosis of the cavity and change of the adjacent structures. Basing on the analysis of these signs correct diagnosis was established in 34 of 35 examinees (97.1 %)

  19. Type A aortic dissection in Marfan syndrome: extent of initial surgery determines long-term outcome.

    Science.gov (United States)

    Rylski, Bartosz; Bavaria, Joseph E; Beyersdorf, Friedhelm; Branchetti, Emanuela; Desai, Nimesh D; Milewski, Rita K; Szeto, Wilson Y; Vallabhajosyula, Prashanth; Siepe, Matthias; Kari, Fabian A

    2014-04-01

    Data on outcomes after Stanford type A aortic dissection in patients with Marfan syndrome are limited. We investigated the primary surgery and long-term results in patients with Marfan syndrome who suffered aortic dissection. Among 1324 consecutive patients with aortic dissection type A, 74 with Marfan syndrome (58% men; median age, 37 years [first and third quartiles, 29 and 48 years]) underwent surgical repair (85% acute dissections; 68% DeBakey I; 55% composite valved graft, 30% supracoronary ascending replacement, 15% valve-sparing aortic root replacement; 12% total arch replacement; 3% in-hospital mortality) at 2 tertiary centers in the United States and Europe over the past 25 years. The rate of aortic reintervention with resternotomy was 24% (18 of 74) and of descending aorta (thoracic+abdominal) intervention was 30% (22 of 74) at a median follow-up of 8.4 years (first and third quartiles, 2.2 and 12.7 years). Freedom from need for aortic root reoperation in patients who underwent primarily a composite valved graft or valve-sparing aortic root replacement procedure was 95±3%, 88±5%, and 79±5% and in patients who underwent supracoronary ascending replacement was 83±9%, 60±13%, 20±16% at 5, 10, and 20 years. Secondary aortic arch surgery was necessary only in patients with initial hemi-arch replacement. Emergency surgery for type A dissection in patients with Marfan syndrome is associated with low in-hospital mortality. Failure to extend the primary surgery to aortic root or arch repair leads to a highly complex clinical course. Aortic root replacement or repair is highly recommended because supracoronary ascending replacement is associated with a high need (>40%) for root reintervention.

  20. Evaluation of aortic distensibility using cine MR imaging

    International Nuclear Information System (INIS)

    Takahashi, Masashi; Murata, Kiyoshi; Mori, Masayuki

    1992-01-01

    Regional aortic distensibility was measured noninvasively using cine MR imaging to determine whether it correlates with aging or risk of coronary artery disease (CAD). Twenty-two patients with CAD confirmed by angiography and 33 without CAD underwent cine MR imaging. Thirty-two sequential images were obtained in one cardiac cycle. The cross sectional area of the descending thoracic aorta was measured on both diastolic (A) and systolic (A') images. Aortic distensibility (A.D.) was calculated from the following equation: A.D.=(A'-A)/A/ΔP.(ΔP represents pulse pressure). Results of a simple regression analysis showed that decreased regional aortic distensibility was significantly correlated with the age of the patients (r=-0.762, p<0.005). In addition, the parameter was lower in patients with CAD than those without CAD (p<0.05). In conclusion, regional aortic distensibility derived from cine MR imaging is a useful parameter to evaluate not only aging but also pathological atherosclerosis of the aorta. In addition, this parameter might have some potential to evaluate the prediction of CAD in patients with normal serum cholesterol. (author)

  1. Case report: ruptured aortic aneurysm into oesophagus - treatment by covered stent

    International Nuclear Information System (INIS)

    Young, N.; Tan, I.; Costa, R.

    2002-01-01

    Full text: A case report of a 70 year old man acutely presenting with a large descending thoracic aortic aneurysm, ruptured into the adjacent oesophagus. He was treated with an Aneurex covered stent (Medtronics). This patient has a long history of ischaemic heart disease, hypertension and previously treated abdominal aortic aneurysm. After diagnosis by CT, the bleeding was emergency temponaded by insertion of a Sengstaken-Blackmore tube into the oesophagus and inflated to arterial pressure. After stabilisation in ICU, it was decided that open surgery would probably prove fatal, and insertion of a covered thoracic aortic stent was performed in theatre with a femoral artery cut-down. Post-operatively the bleeding from the aortic aneurysm ceased. However, the patient has ongoing problems with large, open oesophageal ulcer with chronic ooze requiring intermittent transfusions, chronic infection with MRSA, requiring long term antibiotics, feeding via feeding gastrostomy tubes. The patient is stable 12 months after presentation. Treatment of this otherwise fatal problem by covered stent has permitted survival benefit. However, there are significant, unresolved issues of oesophageal ulcer and ongoing MRSA infection. Copyright (2002) Blackwell Science Pty Ltd

  2. [Descending ocular myopathy].

    Science.gov (United States)

    de Freitas, M R; Nascimento, O J

    1975-06-01

    The case of a 23 years old female patient, with primary involvement of the extraocular and faringeal muscles without familiar history is reported. Electromyographic and muscular biopsy studies proved the myogenic nature of the process. A clinical comparison between the ocular myopathy and the descending ocular myopathy is made, the authors thinking that both of them would be variants of the same muscle disease.

  3. Intramural hemorrhage of the thoracic aorta - imaging features and differential diagnosis; Das intramurale Haematom der thorakalen Aorta: Bildgebende Diagnostik und Differentialdiagnose

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T. [Bonn Univ. (Germany) Radiologische Klinik; Abu-Ramadan, D. [Bonn Univ. (Germany). Klinik fuer Herz- und Gefaesschirurgie; Busch, M. [Bonn Univ. (Germany) Radiologische Klinik; Bierhoff, E. [Bonn Univ. (Germany). Pathologische Inst.; Kreft, B. [Bonn Univ. (Germany) Radiologische Klinik; Kuhl, C. [Bonn Univ. (Germany) Radiologische Klinik; Lutterbey, G. [Bonn Univ. (Germany) Radiologische Klinik; Keller, E. [Bonn Univ. (Germany) Radiologische Klinik; Schild, H. [Bonn Univ. (Germany) Radiologische Klinik

    1996-09-01

    Purpose: Aortic wall thickening due to intramural hemorrhage may be the only sign of aortic dissection. The aim of this study was to evaluate the incidence, imaging features and differential diagnoses of intramural hemorrhage (IMH) of the thoracic aorta. Methods: 98 patients with clinically suspected aortic dissection were investigated via Spiral-CT and MRT. Diagnosis of IMH based on the presence of smooth crescentic or concentric wall thickening over a longer segment of the thoracic aorta without flow visualization and without compression or distortion of the aortic lumen. Results: 69 patients had classic aortic dissections and 7 patients were diagnosed to have IMH of the thoracic aorta. One patient with IMH of the ascending aorta died of aortic rupture and subsequent pericardial tamponade 12 hours after onset of symptoms. In one patient with IMH of the descending aorta on initial examination, there was a progression of overt aortic dissection at follow-up after three weeks. In two patients with IMH of the descending aorta, wall thickening decreased in size at follow-up (10-15 weeks), whereas in one patient it remained unchanged. Conclusion: IMH of the aorta should be considered a precursor of aortic dissection. At follow-up IMH may decrease in size, rupture or progress to overt aortic dissection. (orig.) [Deutsch] Ziel: Eine aortale Wandverdichtung als Ausdruck eines intramuralen Haematoms kann die einzige Manifestation einer Aortendissektion sein. Ziel dieser Arbeit war die Evaluierung der Inzidenz, bildgebenden Aspekte und Differentialdiagnosen dieses in der deutschsprachigen Literatur wenig bekannten Krankheitsbildes. Methode: 98 Patienten mit klinischem Verdacht auf eine Aortendissektion wurden MR- und computertomographisch untersucht. Kriterium fuer das Vorliegen eines intramuralen Haematoms war der Nachweis einer laengerstreckigen aortalen Wandverdickung ohne Flussnachweis sowie ohne Konfigurationsaenderung des aortalen Lumens. Ergebnisse: 69 Patienten

  4. Measurement of the aortic diameter in the asymptomatic Korean population: Assessment with multidetector CT

    International Nuclear Information System (INIS)

    Lee, Sang Hwan; Lee, Whal; Choi, Hyuck Jae; Kim, Dae Jin; Park, Eun Ah; Chung, Jin Wook; Park, Jae Hyung

    2013-01-01

    To determine normal reference values for aortic diameters in asymptomatic Korean adults. Three hundred adults without signs or symptoms of cardiovascular diseases were enrolled in this study. Aortic diameters were measured at nine predetermined levels on CT images. Aortic diameter measurements were adjusted for body surface area. Analysis of data was performed with regard to age, sex, weight, height and hypertension. Aortic diameters were 2.99 ± 0.57 cm at the ascending aorta, 2.54 ± 0.35 cm at the transverse aortic arch, 2.36 ± 0.35 cm at the proximal descending thoracic aorta (DTA), 2.23 ± 0.37 cm at the mid DTA, 2.17 ± 0.38 cm at the distal DTA, 2.16 ± 0.37 cm at the thoracoabdominal junction, 2.10, 00B1, 0.35 cm at the level of the celiac axis, 1.94, 00B1, 0.36 cm at the suprarenal aorta, 1.58 ± 0.24 cm at the aortic bifurcation. Men had slightly larger diameters than women (p < 0.05). All diameters increased with age and hypertension, with statistical significance (p < 0.01). And all aortic diameters increased with height (p < 0.05) except at the level of the aortic arch (p = 0.056), and increased with weight (p < 0.05) except at the level of the suprarenal aorta (p = 0.067). Male sex, higher weight and height, age and hypertension are associated with larger aortic diameters in asymptomatic Korean adults.

  5. Thoracoabdominal aortic aneurysm repair in patients with marfan syndrome.

    Science.gov (United States)

    Mommertz, G; Sigala, F; Langer, S; Koeppel, T A; Mess, W H; Schurink, G W H; Jacobs, M J

    2008-02-01

    We assessed the surgical outcome of descending thoracic aortic aneurysm repair (DTAA) and thoracoabdominal aortic aneurym (TAAA) repair in patients with Marfan syndrome. During a six year period, 206 patients underwent DTAA and TAAA repair. In 22 patients, Marfan syndrome was confirmed. The median age was 40 years with a range between 18 and 57 years. The extend of the aneurysms included 6 DTAA (1 with total arch, 2 with distal hemi-arch), 11 type II TAAA (2 with total arch, 3 with distal hemi-arch), 4 type III and one type IV TAAA. All patients suffered from previous type A (n=6) or type B (n=16) aortic dissection and 15 already underwent aortic procedures like Bentall (n=7) and ascending aortic replacement (n=8). All patients were operated on according to the standard protocol with cerebrospinal fluid drainage, distal aortic and selective organ perfusion and monitoring motor evoked potentials. In patients undergoing simultaneous arch replacement (via left thoracotomy), transcranial Doppler and EEG assessed cerebral physiology during antegrade brain perfusion. In four patients circulatory arrest under moderate hypothermia was required. In-hospital mortality did not occur. Major postoperative complications like paraplegia, renal failure, stroke and myocardial infarction were not encountered. Mean pre-operative creatinine level was 125mmol/L, which peaked to a mean maximal level of 130 and returned to 92mmol/L at discharge. Median intubation time was 1.5 days (range 0.33-30 days). Other complications included bleeding requiring surgical intervention (n=1), arrhythmia (n=2), pneumonia (n=2) and respiratory distress syndrome (n=1). At a median follow-up of 38 months all patients were alive. Using CT surveillance, new or false aneurysms were not detected, except in one patient who developed a visceral patch aneurysm six years after open type II repair. Surgical repair of descending and thoracoabdominal aortic aneurysms provides excellent short- and mid-term results in

  6. First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

    International Nuclear Information System (INIS)

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H.; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M.; Borm, Paul J. A.; Jacob, Augustinus L.; Bilecen, Deniz

    2009-01-01

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

  7. First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept.

    Science.gov (United States)

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J A; Jacob, Augustinus L; Bilecen, Deniz

    2009-05-01

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

  8. Scan-rescan reproducibility of segmental aortic wall shear stress as assessed by phase-specific segmentation with 4D flow MRI in healthy volunteers.

    Science.gov (United States)

    van der Palen, Roel L F; Roest, Arno A W; van den Boogaard, Pieter J; de Roos, Albert; Blom, Nico A; Westenberg, Jos J M

    2018-05-26

    The aim was to investigate scan-rescan reproducibility and observer variability of segmental aortic 3D systolic wall shear stress (WSS) by phase-specific segmentation with 4D flow MRI in healthy volunteers. Ten healthy volunteers (age 26.5 ± 2.6 years) underwent aortic 4D flow MRI twice. Maximum 3D systolic WSS (WSSmax) and mean 3D systolic WSS (WSSmean) for five thoracic aortic segments over five systolic cardiac phases by phase-specific segmentations were calculated. Scan-rescan analysis and observer reproducibility analysis were performed. Scan-rescan data showed overall good reproducibility for WSSmean (coefficient of variation, COV 10-15%) with moderate-to-strong intraclass correlation coefficient (ICC 0.63-0.89). The variability in WSSmax was high (COV 16-31%) with moderate-to-good ICC (0.55-0.79) for different aortic segments. Intra- and interobserver reproducibility was good-to-excellent for regional aortic WSSmax (ICC ≥ 0.78; COV ≤ 17%) and strong-to-excellent for WSSmean (ICC ≥ 0.86; COV ≤ 11%). In general, ascending aortic segments showed more WSSmax/WSSmean variability compared to aortic arch or descending aortic segments for scan-rescan, intraobserver and interobserver comparison. Scan-rescan reproducibility was good for WSSmean and moderate for WSSmax for all thoracic aortic segments over multiple systolic phases in healthy volunteers. Intra/interobserver reproducibility for segmental WSS assessment was good-to-excellent. Variability of WSSmax is higher and should be taken into account in case of individual follow-up or in comparative rest-stress studies to avoid misinterpretation.

  9. One-stage surgery in combination with thoracic endovascular grafting and resection of T4 lung cancer invading the thoracic aorta and spine

    OpenAIRE

    Sato, Seijiro; Goto, Tatsuya; Koike, Terumoto; Okamoto, Takeshi; Shoji, Hirokazu; Ohashi, Masayuki; Watanabe, Kei; Tsuchida, Masanori

    2017-01-01

    A novel strategy of one-stage surgery in combination with thoracic endovascular grafting and resection for T4 lung cancer invading the thoracic aorta and spine is described. A 56-year-old man with locally advanced lung cancer infiltrating the aortic wall and spine underwent neoadjuvant chemotherapy and thoracic irradiation, followed by en bloc resection of the aortic wall and spine with thoracic endovascular grafting. He developed postoperative chylothorax, but there were no stent graft-relat...

  10. Thoracic CT

    Science.gov (United States)

    ... through a vein (IV) in your hand or forearm. It may be given through the rectum using ... CT scan Vertebra, thoracic (mid back) Normal lung anatomy Thoracic organs References Gotway MB, Panse PM, Gruden ...

  11. Aortic valve bypass surgery in severe aortic valve stenosis: Insights from cardiac and brain magnetic resonance imaging.

    Science.gov (United States)

    Mantini, Cesare; Caulo, Massimo; Marinelli, Daniele; Chiacchiaretta, Piero; Tartaro, Armando; Cotroneo, Antonio Raffaele; Di Giammarco, Gabriele

    2018-04-13

    To investigate and describe the distribution of aortic and cerebral blood flow (CBF) in patients with severe valvular aortic stenosis (AS) before and after aortic valve bypass (AVB) surgery. We enrolled 10 consecutive patients who underwent AVB surgery for severe AS. Cardiovascular magnetic resonance imaging (CMR) and brain magnetic resonance imaging were performed as baseline before surgery and twice after surgery. Quantitative flow measurements were obtained using 1.5-T magnetic resonance imaging (MRI) scanner phase-contrast images of the ascending aorta, descending thoracic aorta (3 cm proximally and distally from the conduit-to-aorta anastomosis), and ventricular outflow portion of the conduit. The evaluation of CBF was performed using 3.0-T MRI scanner arterial spin labeling (ASL) through sequences acquired at the gray matter, dorsal default-mode network, and sensorimotor levels. Conduit flow, expressed as the percentage of total antegrade flow through the conduit, was 63.5 ± 8% and 67.8 ± 7% on early and mid-term postoperative CMR, respectively (P surgery in patients with severe AS, cardiac output is split between the native left ventricular outflow tract and the apico-aortic bypass, with two-thirds of the total antegrade flow passing through the latter and one-third passing through the former. In our experience, CBF assessment confirms that the flow redistribution does not jeopardize cerebral blood supply. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  12. Descending with Angels

    DEFF Research Database (Denmark)

    Suhr, Christian

    2014-01-01

    Islamic exorcism or psychotropic medication? “Descending with Angels” explores two highly different solutions to the same problem: namely Danish Muslims who are possessed by invisible spirits, called jinn. A Palestinian refugee living in the city of Aarhus has been committed to psychiatric......, and directed by Christian Suhr Produced by Persona Film, November 2013 Distribution: Documentary Educational Resources (DER, Watertown) Screening format: DCP / Blu-ray / ProRes / Mpeg4 / DVD / DV SP. Original format: XDCAM 1080p Languages: Arabic, Danish, English Subtitles: English...

  13. Current Evidence and Insights about Genetics in Thoracic Aorta Disease

    Science.gov (United States)

    Muneretto, Claudio

    2013-01-01

    Thoracic aortic aneurysms have been historically considered to be caused by etiologic factors similar to those implied in abdominal aortic aneurysms. However, during the past decade, there has been increasing evidence that almost 20% of thoracic aortic aneurysms may be associated with a genetic disease, often within a syndromic or familial disorder. Moreover, the presence of congenital anomalies, such as bicuspid aortic valve, may have a unique common genetic underlying cause. Finally, also sporadic forms have been found to be potentially associated with genetic disorders, as highlighted by the analysis of rare variants and expression of specific microRNAs. We therefore sought to perform a comprehensive review of the role of genetic causes in the development of thoracic aortic aneurysms, by analyzing in detail the current evidence of genetic alterations in syndromes such as Marfan, Loeys-Dietz, and Ehler-Danlos, familial or sporadic forms, or forms associated with bicuspid aortic valve. PMID:24453931

  14. Unlikely culprit: congenital middle aortic syndrome diagnosed in the sixth decade of life.

    Science.gov (United States)

    Ali, Muhammad Sajawal; Tchernodrinski, Stefan; Mohananey, Divyanshu; Ali, Ahya Sajawal

    2016-08-16

    A 58-year-old woman was admitted with acute heart failure. She had a long history of resistant hypertension, with an unremarkable work up for secondary causes in the past. Her brachial blood pressure was 210/70 mm Hg, with ankle blood pressure of 100/70 mm Hg. CT angiogram revealed marked narrowing of the descending thoracic aorta between the left subclavian artery and the diaphragm, consistent with middle aortic syndrome (MAS). She was initially managed with diuretics and antihypertensives. Subsequently thoracotomy revealed a severely hypoplastic segment of the descending aorta. The diseased segment was resected and aortic reconstruction performed. Histopathology showed fragmentation of the medial elastic fibres and fibrosis of the medial and intimal layers. These findings along with gross aortic hypoplasia and absence of features of Takayasu's arteritis, suggest that our patient had congenital MAS. The patient has done well since her surgery. We believe this is the first case of congenital MAS reported in the sixth decade of life. 2016 BMJ Publishing Group Ltd.

  15. Prevalence and Outcomes of Mitral Stenosis in Patients Undergoing Transcatheter Aortic Valve Replacement: Findings From the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies Registry.

    Science.gov (United States)

    Joseph, Lee; Bashir, Mohammad; Xiang, Qun; Yerokun, Babatunde A; Matsouaka, Roland Albert; Vemulapalli, Sreekanth; Kapadia, Samir; Cigarroa, Joaquin E; Zahr, Firas

    2018-04-09

    This study sought to examine the prevalence of mitral stenosis (MS) and its impact on in-hospital and 1-year clinical outcomes among patients undergoing transcatheter aortic valve replacement (TAVR). Patients with coexisting severe aortic stenosis and MS are increasingly being considered for TAVR. The study cohort included 44,755 patients (age ≥18 years) who underwent TAVR during November 1, 2011, to September 30, 2015, and were registered in Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies (TVT) Registry. One-year outcomes were assessed by linking TVT registry data of this cohort to patient-specific Centers for Medicare & Medicaid Services administrative claims data (n = 31,453). The primary outcome was the composite of death, stroke, heart failure-related hospitalization, and mitral valve intervention at 1 year. MS was present in 11.6% of cohort (mean age, 82 years; 52% males), being severe in 2.7%. Severe MS was associated with higher in-hospital mortality rates (5.6% vs. 3.9% for nonsevere MS and 4.1% for no MS; p = 0.02). In contrast to those without MS, severe MS group had significantly higher risk for the primary outcome, mortality (1 year), and heart failure-related hospitalization (1 year) (adjusted hazard ratio: 1.2 [95% confidence interval (CI): 1.1 to 1.4], 1.2 [95% CI: 1.0 to 1.4], and 1.3 [95% CI: 1.1 to 1.5], respectively; p < 0.05 for all). Approximately one-tenth of patients undergoing TAVR have concomitant MS. Severe MS is an independent predictor of 1-year adverse clinical outcomes following TAVR. The higher risk for long-term adverse events must be considered when evaluating patients with combined aortic stenosis and MS for TAVR. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. The novel EuroSCORE II algorithm predicts the hospital mortality of thoracic aortic surgery in 461 consecutive Japanese patients better than both the original additive and logistic EuroSCORE algorithms.

    Science.gov (United States)

    Nishida, Takahiro; Sonoda, Hiromichi; Oishi, Yasuhisa; Tanoue, Yoshihisa; Nakashima, Atsuhiro; Shiokawa, Yuichi; Tominaga, Ryuji

    2014-04-01

    The European System for Cardiac Operative Risk Evaluation (EuroSCORE) II was developed to improve the overestimation of surgical risk associated with the original (additive and logistic) EuroSCOREs. The purpose of this study was to evaluate the significance of the EuroSCORE II by comparing its performance with that of the original EuroSCOREs in Japanese patients undergoing surgery on the thoracic aorta. We have calculated the predicted mortalities according to the additive EuroSCORE, logistic EuroSCORE and EuroSCORE II algorithms in 461 patients who underwent surgery on the thoracic aorta during a period of 20 years (1993-2013). The actual in-hospital mortality rates in the low- (additive EuroSCORE of 3-6), moderate- (7-11) and high-risk (≥11) groups (followed by overall mortality) were 1.3, 6.2 and 14.4% (7.2% overall), respectively. Among the three different risk groups, the expected mortality rates were 5.5 ± 0.6, 9.1 ± 0.7 and 13.5 ± 0.2% (9.5 ± 0.1% overall) by the additive EuroSCORE algorithm, 5.3 ± 0.1, 16 ± 0.4 and 42.4 ± 1.3% (19.9 ± 0.7% overall) by the logistic EuroSCORE algorithm and 1.6 ± 0.1, 5.2 ± 0.2 and 18.5 ± 1.3% (7.4 ± 0.4% overall) by the EuroSCORE II algorithm, indicating poor prediction (P algorithms were 0.6937, 0.7169 and 0.7697, respectively. Thus, the mortality expected by the EuroSCORE II more closely matched the actual mortality in all three risk groups. In contrast, the mortality expected by the logistic EuroSCORE overestimated the risks in the moderate- (P = 0.0002) and high-risk (P < 0.0001) patient groups. Although all of the original EuroSCOREs and EuroSCORE II appreciably predicted the surgical mortality for thoracic aortic surgery in Japanese patients, the EuroSCORE II best predicted the mortalities in all risk groups.

  17. Contemporary insights into the management of type A aortic dissection.

    Science.gov (United States)

    Tolis, George; Sundt, Thoralf M

    2016-10-01

    Acute Type A Dissection remains a surgical emergency with a relatively high operative mortality despite advances in cardiac surgical techniques and medical management over the past thirty years. In this presentation we will discuss the issues surrounding diagnosis, triage, surgical treatment and perioperative medical management as well as long term surveillance of patients suffering from Acute Type A Dissection and present the literature that supports our management strategies. Expert commentary: The ultimate goal of surgical intervention for patients with Type A Acute Aortic Dissection is an alive patient. A more complicated operation which addresses the root and arch and potentially reduces late complications should be approached with caution since it may increase the operative mortality of the procedure itself. With the recent evolution in endovascular techniques, there is hope that later complications can be reduced without increasing the risk of the primary operation. It remains to be seen whether the improved distal aortic remodeling afforded by a combined open/endovascular approach to Acute Type A Dissection will lead to decreased need for aortic reinterventions and overall long term complications of a residual descending thoracic chronic dissection.

  18. Intraindividual assessment of the thoracic aorta using contrast and non-contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Tengg-Kobligk, Hendrik von; Gruenberg, K.M.; Giesel, F.L.; Ley-Zaporozhan, J.; Ley, S.; Henninger, V.; Kauczor, H.U.; Radiologische Universitaetsklinik Heidelberg; Boeckler, D.; Krummenauer, F.

    2009-01-01

    To avoid intravenous contrast media application, new MRA sequences using inherent blood contrast are available. The clinical use of these non-contrast-enhanced MRA (non-CE-MRA) sequences is still limited for the aorta. Thus, the goal was to compare a standard CE-MRA with a non-CE-MRA for the thoracic aorta. Ethics committee approval and informed consent were obtained. CE-MRA and non-CE-MRA (1.5T) were performed in the same 50 healthy volunteers (mean age: 48). CE-MRA: GRE-Turbo-Flash-3D (1.2 x 1.2 x 1.6 mm 3 ), 0.15 mmol Gd/kg, TA 22 ± 2sec. Non-CE-MRA: Respiratory-and cardiac-gated, T 2-prepared 3D-trueFISP (1.2 x 1.2 x 1.3 mm 3 ), TA 14 ± 5 min. Assessment included (3 readers, consensus): image quality (sharpness of vessel wall, signal homogeneity, artifacts) at the ascending aorta, arch, descending aorta and supra-aortic vessels. The image quality in the ascending aorta was rated 'excellent' in 78 %, 'moderate' in 22 %, 'poor' in 0 % for non-CE-MRA versus 22 %, 50 %, and 28 % for CE-MRA (Cohen's kappa = 29 %, McNemar p < 0.001). In a comparison of non-CE-MRA versus CE-MRA, the aortic arch and descending aorta showed no significant difference (kappa = 58 %/p = 0.250 and kappa = 100 %/p 1.000, respectively). Supra-aortic vessels were rated 'excellent' 45 %/49 %, 'moderate' 30 %/49 % and 'poor' 13 %/2 %, 12 % of supra-aortic vessels were visualized < 1 cm at non-CE-MRA. (orig.)

  19. Percutaneous endovascular stent-graft treatment of aortic aneurysms and dissections: new techniques and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Choi, Dong Hoon; Kang, Sung Gwon; Lee, Kwang Hoon; Won, Jong Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kang, Sung Gwon [Chosun University College of Medicine, Gwangju (Korea, Republic of); Won, Je Whan [Aju University College of Medicine, Suwon (Korea, Republic of); Song, Ho Young [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2003-01-01

    To evaluate the feasibility, safety and effectiveness of a newly designed percutaneously implanted separate stent-graft (SSG) for the treatment of aortic aneurysms and dissections. Using a percutaneous technique, SSG placement (in the descending thoracic aorta in 26 cases and infrarenal abdominal aorta in 24) was attempted in 50 patients with aortic aneurysms (n=27) or dissection (n=23). All SSGs were individually constructed using self-expandable nitinol stents and a Dacron graft, and were introduced through a 12 F sheath and expanded to a diameter of 20-34 mm. In all cases, vascular access was through the femoral artery. The clinical status of each patient was monitored, and postoperative CT was performed within one week of the procedure and at 3-6 month intervals afterwards. Endovascular stent-graft deployment was technically successful in 49 of 50 patients (98%). The one failure was due to torsion of the unsupported graft during deployment. Successful exclusion of aneurysms and the primary entry tears of dissections was achieved in all but three patients with aortic dissection. All patients in whom technical success was achieved showed complete thrombosis of the thoracic false lumen or aneurysmal sac, and the overall technique success rate was 92%. In addition, sixteen patients demonstrated complete resolution of the dissected thoracic false lumen (n=9) or aneurysmal sac (n=7). Immediate post-operative complications occurred at the femoral puncture site in one patient with an arteriovenous fistula, and in two, a new saccular aneurysm developed at the distal margin of the stent. No patients died, and there was no instance of paraplegia, stroke, side-branch occlusion or infection during the subsequent mean follow-up period of 9.4 (range, 2 to 26) months. In patients with aortic aneurysm and dissection, treatment with a separate percutaneously inserted stent-graft is technically feasible, safe, and effective.

  20. Helical CT of traumatic injuries of the thoracic aorta

    International Nuclear Information System (INIS)

    Mengozzi, E.; Burzi, M.; Miceli, M.; Lipparini, M.; Sartoni Galloni, S.

    2000-01-01

    Acute thoracic aortic injuries account for up to 10-20% of fatalities in high-speed deceleration road accidents and have an estimated immediate fatality rate of 80-90%. Untreated survivors to acute trauma (10-20%) have a dismal prognosis: 30% of them die within 6 hours, 40-50% die within 24 hours, and 90% within 4 months. It was investigated the diagnostic accuracy of Helical Computed Tomography (Helical CT) in acute traumatic injuries of the thoracic aorta, and the role of this technique in the diagnostic management of trauma patients with a strong suspicion of aortic rupture. It was compared retrospectively the chest Helical CT findings of 256 trauma patients examined June 1995 through August 1999. Chest Helical CT examinations were performed according to trauma score, to associated traumatic lesions and to plain chest radiographic findings. All the examinations were performed with no intravenous contrast agent administration and the pitch 2 technique. After a previous baseline study, contrast-enhanced scans were acquired with pitch 1 in 87 patients. Helical CT showed aortic lesions in 9 of 256 patients examined. In all the 9 cases it was found a mediastinal hematoma and all of them had positive plain chest radiographic findings of mediastinal enlargement. Moreover, in 6 cases aortic knob blurring was also evident on plain chest film and in 5 cases depressed left mainstem bronchus and trachea deviation rightwards were observed. All aortic lesions were identified on axial scans and located at the isthmus of level. Aortic rupture was always depicted as pseudo diverticulum of the proximal descending tract and intimal flap. It was also found that periaortic hematoma in 6 cases and intramural hematoma in 1 case. There were non false positive results in the series: 7 patients with Helical CT diagnosis of aortic rupture were submitted to conventional aortography that confirmed both type and extension of the lesions as detected by Helical CT, and all findings were

  1. Tratamiento endovascular de urgencia con endoprótesis de aneurisma roto disecado de aorta torácica: A propósito de un caso Emergency endovascular treatment with endoprosthesis of ruptured dissected aneurysm of thoracic aorta: Report of one case

    Directory of Open Access Journals (Sweden)

    José Lugo

    2007-12-01

    Full Text Available Los aneurismas de aorta torácica son menos comunes que los aneurismas de aorta abdominal y pueden encontrarse en aorta ascendente, arco aórtico, aorta descendente o en una combinación de estos segmentos. De estos aneurismas el 30% al 40% se originan en la aorta torácica descendente. En los aneurismas de aorta torácica existe una debilidad estructural de la pared de la aorta, que conlleva una dilatación arterial progresiva con eventual ruptura o disección. Aproximadamente, 50% de los aneurismas de aorta torácica son ateroscleróticos y ocurren como resultado de remodelado arterial y dilatación o a raíz de un metabolismo anormal del colágeno. La mayoría de los aneurismas de aorta torácica se descubren por casualidad durante la evaluación de otros problemas médicos. La meta del tratamiento de los aneurismas de aorta torácica, es prevenir la muerte debido a su ruptura. El riesgo de ruptura de los no tratados oscila entre 46% a 74% y la tasa de mortalidad por su ruptura es extremadamente alta. Los aneurismas de gran tamaño, en especial aquellos mayores de 6 cm, son más susceptibles de rupturas que los aneurismas de menor tamaño. El tratamiento endovascular, inicialmente desarrollado para los aneurismas de aorta abdominal, se introdujo en 1992 como una alternativa menos invasiva al tratamiento de cirugía abierta para los aneurismas de la aorta torácica descendente. En la actualidad, el injerto de stent endovascular en la aorta descendente o endoprótesis, recibe mayor atención como alternativa al reparo quirúrgico de los aneurismas de aorta torácica.Thoracic aortic aneurysms are less common than abdominal aortic aneurysms and can be found in ascending aorta, aortic arch, descending aorta or in a combination of these segments. 30% to 40% of these aneurysms are originated in thoracic descending aorta. In thoracic aortic aneurysms there exists a structural wall weakness that leads to a progressive arterial dilation with eventual

  2. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch.

    Science.gov (United States)

    Millan-Iturbe, Oscar; Sawaya, Fadi J; Bieliauskas, Gintautas; Chow, Danny H F; De Backer, Ole; Søndergaard, Lars

    2017-09-01

    Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high/intermediate-risk patients with severe symptomatic aortic stenosis (AS). Although TAVR is used to treat bicuspid severe AS, the large randomized trials typically excluded bicuspid AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a "gothic aortic arch"; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled a sharply angulated aortic arch. This life-threatening complication was successfully treated by thoracic endovascular aortic repair. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  3. Manejo endovascular de la aorta torácica Endovascular treatment of thoracic aorta

    Directory of Open Access Journals (Sweden)

    Juan G Barrera

    2006-10-01

    Full Text Available En comparación con el tratamiento convencional, la terapia endovascular en aneurisma de aorta torácica, presenta los mejores resultados, por lo que se convierte en el tratamiento de elección para la patología de aorta torácica descendente endovascular, por su baja morbimortalidad perioperatoria. El tratamiento quirúrgico por vía retroperitoneal y/o endovascular para aneurisma de aorta abdominal infrarrenal, resulta ser especialmente seguro en pacientes octogenarios o con alta morbilidad. Esta cohorte institucional presenta resultados perioperatorios y en el seguimiento, similares a los reportados en la literatura mundial.Compared with the conventional treatment, endovascular therapy in thoracic aortic aneurysm shows the best results, being the election treatment for the pathology of the descending thoracic aorta, due to its low peri-operative morbid-mortality. Surgical treatment by retro-peritoneal route and/or endovascular for infra-renal abdominal aortic aneurysm is especially safe in octogenarian patients or in those with a high mortality rate. This institutional cohort show peri-operative and follow-up results similar to those reported in the world literature.

  4. Magnetic resonance imaging 4-D flow-based analysis of aortic hemodynamics in Turner syndrome

    International Nuclear Information System (INIS)

    Arnold, Raoul; Neu, Marie; Hirtler, Daniel; Gimpel, Charlotte; Markl, Michael; Geiger, Julia

    2017-01-01

    Cardiovascular surveillance is important in Turner syndrome because of the increased risk of aortic dilation and dissection with consecutively increased mortality. To compare 4-D flow MRI for the characterization of aortic 3-D flow patterns, dimensions and vessel wall parameters in pediatric patients with Turner syndrome and age-matched controls. We performed 4-D flow MRI measuring in vivo 3-D blood flow with coverage of the thoracic aorta in 25 patients with Turner syndrome and in 16 female healthy controls (age mean ± standard deviation were 16 ± 5 years and 17 ± 4 years, respectively). Blood flow was visualized by time-resolved 3-D path lines. Visual grading of aortic flow in terms of helices and vortices was performed by two independent observers. Quantitative analysis included measurement of aortic diameters, quantification of peak systolic wall shear stress, pulsatility index and oscillatory shear index at eight defined sites. Patients with Turner syndrome had significantly larger aortic diameters normalized to BSA, increased vortices in the ascending aorta and elevated helix flow in the ascending and descending aorta compared to controls (all P<0.03). Patients with abnormal helical or vortical flow in the ascending aorta had significantly larger diameters of the ascending aorta (P<0.03). Peak systolic wall shear stress, pulsatility index and oscillatory shear index were significantly lower in Turner patients compared to controls (p=0.02, p=0.002 and p=0.01 respectively). Four-dimensional flow MRI provides new insights into the altered aortic hemodynamics and wall shear stress that could have an impact on the development of aortic dissections. (orig.)

  5. Magnetic resonance imaging 4-D flow-based analysis of aortic hemodynamics in Turner syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, Raoul [University Medical Center Heidelberg, Department of Congenital Heart Disease and Pediatric Cardiology, Heidelberg (Germany); Neu, Marie [University Medical Center, Department of Pediatric Hematology/Oncology/Hemostaseology, Mainz (Germany); Hirtler, Daniel [University of Freiburg, Department of Congenital Heart Defects and Pediatric Cardiology, Heart Center, Freiburg im Breisgau (Germany); Gimpel, Charlotte [Center for Pediatrics, Medical Center - University of Freiburg, Department of General Pediatrics, Adolescent Medicine and Neonatology, Freiburg im Breisgau (Germany); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Chicago, IL (United States); Geiger, Julia [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); University Children' s Hospital, Department of Radiology, Zuerich (Switzerland)

    2017-04-15

    Cardiovascular surveillance is important in Turner syndrome because of the increased risk of aortic dilation and dissection with consecutively increased mortality. To compare 4-D flow MRI for the characterization of aortic 3-D flow patterns, dimensions and vessel wall parameters in pediatric patients with Turner syndrome and age-matched controls. We performed 4-D flow MRI measuring in vivo 3-D blood flow with coverage of the thoracic aorta in 25 patients with Turner syndrome and in 16 female healthy controls (age mean ± standard deviation were 16 ± 5 years and 17 ± 4 years, respectively). Blood flow was visualized by time-resolved 3-D path lines. Visual grading of aortic flow in terms of helices and vortices was performed by two independent observers. Quantitative analysis included measurement of aortic diameters, quantification of peak systolic wall shear stress, pulsatility index and oscillatory shear index at eight defined sites. Patients with Turner syndrome had significantly larger aortic diameters normalized to BSA, increased vortices in the ascending aorta and elevated helix flow in the ascending and descending aorta compared to controls (all P<0.03). Patients with abnormal helical or vortical flow in the ascending aorta had significantly larger diameters of the ascending aorta (P<0.03). Peak systolic wall shear stress, pulsatility index and oscillatory shear index were significantly lower in Turner patients compared to controls (p=0.02, p=0.002 and p=0.01 respectively). Four-dimensional flow MRI provides new insights into the altered aortic hemodynamics and wall shear stress that could have an impact on the development of aortic dissections. (orig.)

  6. Elective reconstruction of thoracoabdominal aortic aneurysm type IV by transabdominal approach

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2012-01-01

    Full Text Available Introduction. Thoracoabdominal aortic aneurysm (TAAA type IV represents an aortic dilatation from the level of the diaphragmatic hiatus to the iliac arteries branches, including visceral branches of the aorta. In the traditional procedure of TAAA type IV repair, the body is opened using thoractomy and laparotomy in order to provide adequate exposure of the descending thoracic and abdominal aorta for safe aortic reconstruction. Case report. We reported a 71-yearold man with elective reconstruction of the TAAA type IV performed by transabdominal approach. Computed tomography scans angiography revealed a TAAA type IV with diameter of 62 mm in the region of celiac trunk and superior mesenteric artery branching, and the largest diameter of 75 mm in the infrarenal aortic level. The patient comorbidity included a chronic obstructive pulmonary disease and hypertension, therefore he was treated for a prolonged period. In preparation for the planned aortic reconstruction asymptomatic carotid disease (occlusion of the left internal carotid artery and subtotal stenosis of the right internal carotid artery was diagnosed. Within the same intervention percutaneous transluminal angioplasty with stent placement in right internal carotid artery was made. In general, under endotracheal anesthesia and epidural analgesia, with transabdominal approach performed aortic reconstruction with tubular dakron graft 24 mm were, and reimplantation of visceral aortic branches into the graft performed. Postoperative course was uneventful, and the patient was discharged on the postoperative day 17. Control computed tomography scan angiography performed three months after the operation showed vascular state of the patient to be in order. Conclusion. Complete transabdominal approach to TAAA type IV represents an appropriate substitute for thoracoabdominal approach, without compromising safety of the patient. This approach is less traumatic, especially in patients with impaired

  7. Early Results of Chimney Technique for Type B Aortic Dissections Extending to the Aortic Arch

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chen [Affiliated Hospital of Nantong University, Department of General Surgery (China); Tang, Hanfei; Qiao, Tong; Liu, Changjian; Zhou, Min, E-mail: 813477618@qq.com [The Affiliated Hospital of Nanjing University Medical School, Department of Vascular Surgery, Nanjing Drum Tower Hospital (China)

    2016-01-15

    ObjectiveTo summarize our early experience gained from the chimney technique for type B aortic dissection (TBAD) extending to the aortic arch and to evaluate the aortic remodeling in the follow-up period.MethodsFrom September 2011 to July 2014, 27 consecutive TBAD patients without adequate proximal landing zones were retrograde analyzed. Chimney stent-grafts were deployed parallel to the main endografts to reserve flow to branch vessels while extending the landing zones. In the follow-up period, aortic remodeling was observed with computed tomography angiography.ResultsThe technical success rate was 100 %, and endografts were deployed in zone 0 (n = 3, 11.1 %), zone 1 (n = 18, 66.7 %), and zone 2 (n = 6, 22.2 %). Immediately, proximal endoleaks were detected in 5 patients (18.5 %). During a mean follow-up period of 17.6 months, computed tomography angiography showed all the aortic stent-grafts and chimney grafts to be patent. Favorable remodeling was observed at the level of maximum descending aorta and left subclavian artery with expansion of true lumen (from 18.4 ± 4.8 to 25 ± 0.86 mm, p < 0.001 and 27.1 ± 0.62 to 28.5 ± 0.37 mm, p < 0.001) and depressurization of false lumen (from 23.7 ± 2.7 to 8.7 ± 3.8 mm, p < 0.001, from 5.3 ± 1.2 to 2.1 ± 2.1 mm, p < 0.001). While at the level of maximum abdominal aorta, suboptimal remodeling of the total aorta (from 24.1 ± 0.4 to 23.6 ± 1.5 mm, p = 0.06) and true lumen (from 13.8 ± 0.6 to 14.5 ± 0.4 mm, p = 0.08) was observed.ConclusionBased on our limited experience, the chimney technique with thoracic endovascular repair is demonstrated to be promising for TBAD extending to the arch with favorable aortic remodeling.

  8. Impact of Aortic Insufficiency on Ascending Aortic Dilatation and Adverse Aortic Events After Isolated Aortic Valve Replacement in Patients With a Bicuspid Aortic Valve.

    Science.gov (United States)

    Wang, Yongshi; Wu, Boting; Li, Jun; Dong, Lili; Wang, Chunsheng; Shu, Xianhong

    2016-05-01

    Aberrant flow pattern and congenital fragility bestows bicuspid aortic valve (BAV) with a propensity toward ascending aorta dilatation, aneurysm, and dissection. Whether isolated aortic valve replacement (AVR) can prevent further dilatation in BAV ascending aorta and what indicates concurrent aortic intervention in the case of valve operation remain controversial. From June 2006 to January 2009, patients with a BAV who underwent isolated AVR were consecutively included and categorized into aortic insufficiency (BAV-AI, n = 84) and aortic stenosis (n = 112) groups, and another population of patients with a tricuspid aortic valve with aortic insufficiency (n = 149) was also recruited during the same period for comparison of annual aortic dilatation rate and adverse aortic events after isolated AVR. With a median follow-up period of 72 months (interquartile range, 66 to 78 months), ascending aorta dilatation rates were faster in the BAV-AI group than the BAV plus aortic stenosis and tricuspid aortic valve with aortic insufficiency groups (both p regression analysis identified aortic insufficiency (hazard ratio, 3.7; 95% confidence interval, 1.2 to 11.1; p = 0.019) as an independent risk factor for adverse aortic events among patients with BAV in general, whereas preoperative ascending aortic diameter larger than 45 mm (hazard ratio, 13.8; 95% confidence interval, 3.0 to 63.3; p = 0.001) served as a prognostic indicator in the BAV-AI group. An aggressive policy of preventive aortic interventions seemed appropriate in patients with BAV-AI during AVR, and BAV phenotype presenting as either insufficiency or stenosis should be taken into consideration when contemplating optimal surgical strategies for BAV aortopathy. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Conventional versus frozen elephant trunk surgery for extensive disease of the thoracic aorta.

    Science.gov (United States)

    Di Eusanio, Marco; Borger, Michael; Petridis, Francesco D; Leontyev, Sergey; Pantaleo, Antonio; Moz, Monica; Mohr, Friedrich; Di Bartolomeo, Roberto

    2014-11-01

    To compare early and mid-term outcomes after repair of extensive aneurysm of the thoracic aorta using the conventional elephant trunk or frozen elephant trunk (FET) procedures. Fifty-seven patients with extensive thoracic aneurysmal disease were treated using elephant trunk (n = 36) or FET (n = 21) procedures. Patients with aortic dissection, descending thoracic aorta (DTA) diameter less than 40 mm, and thoracoabdominal aneurysms were excluded from the analysis, as were those who did not undergo antegrade selective cerebral perfusion during circulatory arrest. Short-term and mid-term outcomes were compared according to elephant trunk/FET surgical management. Preoperative and intraoperative variables were similar in the two groups, except for a higher incidence of female sex, coronary artery disease and associated procedures in elephant trunk patients. Hospital mortality (elephant trunk: 13.9% versus FET: 4.8%; P = 0.2), permanent neurologic dysfunction (elephant trunk: 5.7% versus FET: 9.5%; P = 0.4) and paraplegia (elephant trunk: 2.9% versus FET: 4.8%; P = 0.6) rates were similar in the two groups. Follow-up was 100% complete. In the elephant trunk group, 68.4% of patients did not undergo a second-stage procedure during follow-up for a variety of reasons. Of these patients, the DTA diameter was greater than 51 mm in 72.2% and two (6.7%) died due to aortic rupture while awaiting stage-two intervention. Endovascular second-stage procedures were successfully performed in all FET patients with residual DTA aneurysmal disease (n = 3), whereas nine of 11 elephant trunk patients who returned for second-stage procedures required conventional surgical replacement through a lateral thoracotomy. Kaplan-Meier estimate of 4-year survival was 75.8 ± 7.6 and 72.8 ± 10.6 in elephant trunk and FET patients, respectively (log-rank P = 0.8). In patients with extensive aneurysmal disease of thoracic aorta, elephant trunk and FET procedures

  10. Vessel wall MRI of the thoracic aorta: correlation to histology and transesophageal ultrasound. Preliminary results

    International Nuclear Information System (INIS)

    Abolmaali, N.; Schick, C.; Thalhammer, A.; Schmitt, J.; Vogl, T.J.; Langenfeld, M.; Schaechinger, V.; Krahforst, R.; Schulze, T.

    2002-01-01

    Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T 1 -weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T 2 -weighted turbo spin echo sequences and ECG-triggered and fat suppressed T 1 -weighted spin echo sequences before and after iv administration of Gd-DTPA. Findings of the MR images were compared to the results of TEU. Contrast enhancement measurements were performed in normal and thickened vessel wall segments. Results: For the cadaver study a good correlation of the degree of vessel wall thickening and the extent of plaque imaged with the applied MR protocol was found. Tissue characterisation was limited due to post mortem changes. In vivo ECG-triggered T 1 -weighted images showed good correlation to TEU in terms of vessel wall thickness and plaque extension as verified by means of consensus reading. Differentiation of the plaque components fat, calcium and fibrous tissue was possible. In thickened aortic wall segments and fibrous caps a mean contrast enhancement of 50.4%±23.5% was measurable while normal wall segments showed an enhancement of 6.7%±3.1%. (orig.) [de

  11. Contemporary Management Strategies for Chronic Type B Aortic Dissections: A Systematic Review

    NARCIS (Netherlands)

    Kamman, Arnoud V.; de Beaufort, Hector W. L.; van Bogerijen, Guido H W; Nauta, FJH; Heijmen, Robin H.; Moll, Frans L.; van Herwaarden, Joost A.; Trimarchi, Santi

    2016-01-01

    Background Currently, the optimal management strategy for chronic type B aortic dissections (CBAD) is unknown. Therefore, we systematically reviewed the literature to compare results of open surgical repair (OSR), standard thoracic endovascular aortic repair (TEVAR) or branched and fenestrated TEVAR

  12. Differentiation defect in neural crest-derived smooth muscle cells in patients with aortopathy associated with bicuspid aortic valves

    Directory of Open Access Journals (Sweden)

    Jiao Jiao

    2016-08-01

    Full Text Available Individuals with bicuspid aortic valves (BAV are at a higher risk of developing thoracic aortic aneurysms (TAA than patients with trileaflet aortic valves (TAV. The aneurysms associated with BAV most commonly involve the ascending aorta and spare the descending aorta. Smooth muscle cells (SMCs in the ascending and descending aorta arise from neural crest (NC and paraxial mesoderm (PM, respectively. We hypothesized defective differentiation of the neural crest stem cells (NCSCs-derived SMCs but not paraxial mesoderm cells (PMCs-derived SMCs contributes to the aortopathy associated with BAV. When induced pluripotent stem cells (iPSCs from BAV/TAA patients were differentiated into NCSC-derived SMCs, these cells demonstrated significantly decreased expression of marker of SMC differentiation (MYH11 and impaired contraction compared to normal control. In contrast, the PMC-derived SMCs were similar to control cells in these aspects. The NCSC-SMCs from the BAV/TAA also showed decreased TGF-β signaling based on phosphorylation of SMAD2, and increased mTOR signaling. Inhibition of mTOR pathway using rapamycin rescued the aberrant differentiation. Our data demonstrates that decreased differentiation and contraction of patient's NCSC-derived SMCs may contribute to that aortopathy associated with BAV.

  13. Aortic stiffness and diameter predict progressive aortic dilatation in patients with Marfan syndrome

    NARCIS (Netherlands)

    Nollen, Gijs J.; Groenink, Maarten; Tijssen, Jan G. P.; van der Wall, Ernst E.; Mulder, Barbara J. M.

    2004-01-01

    Aim Patients with Marfan syndrome may develop dissection due to progressive dilatation in the entire aorta, which is not always predictable by mere anatomic assessment of the aortic diameter, especially of the descending aorta. The aim of this study was to identify the predictive value of aortic

  14. Endovascular treatment of thoracic aorta aneurysm and dissection

    International Nuclear Information System (INIS)

    Petrov, I.; Stankov, Z.; Stefanov, St.; Stoyanov, Hr.

    2015-01-01

    Full text: The aim is to give up to date information about modern endovascular treatment of aortic pathology Dissection and aneurysms of the aorta are life threatening condition requiring in most of the cases prompt surgical or endovascular treatment because of the poor natural evolution. Purpose: to assess the immediate and 1-year outcome of endovascular treatment in broad spectrum of acute and subacute aortic syndrome during the last 3 years (November 2012 - August 2015) in City Clinic (Sofia, Bulgaria). We performed endovascular treatment of 47 patients (43 men, 4 women) at average age 54 y. with dissection (24) and aneurysms (23) of the aortic arch and thoracic aorta (in 5 emergent treatment was performed for aortic rupture). All patients were treated with minimal surgical femoral approach. In 4 (9%) of them initial carotid to carotid bypass was performed in order to provide a sufficient landing zone for the endograft implantation.the last 9 patients (19%) were treated without general anesthesia with either deep sedation or epidural anesthesia. Results: In all patients successful endograft implantation was achieved. Additional stent-graft or open cell stent was implanted in 4 cases in order to centralize the flow in the compressed true lumen. In 5 cases additional vascular plug or large coil was delivered in the left subclavian arteryostium in order to interrupt retrograde aneurysm or false lumen filling. Complications: 30 days mortality-2.2%, neurologic disorders (4.4%). one year survival- 45 (90.5%). 3 and 6 mo control CT scan showed no migration of the graft in 100%, full false lumen isolation in 19 out of 24 dissections (80%) and aneurysm free of expansion in 20 out of 23 (86%), patent carotid bay-pass graft in 4 of 4 (100%). This one center study showed excellent immediate and 1 year clinical and device results from endovascular repair of potentially fatal disease. Endovascular treatment is a method of choice for broad spectrum of aortic pathology

  15. Shared Genetic Risk Factors of Intracranial, Abdominal, and Thoracic Aneurysms

    NARCIS (Netherlands)

    van 't Hof, Femke N G; Ruigrok, Ynte M; Lee, Cue Hyunkyu; Ripke, Stephan; Anderson, Graig; de Andrade, Mariza; Baas, Annette F; Blankensteijn, Jan D; Böttinger, Erwin P; Bown, Matthew J; Broderick, Joseph; Bijlenga, Philippe; Carrell, David S; Crawford, Dana C; Crosslin, David R; Ebeling, Christian; Eriksson, Johan G; Fornage, Myriam; Foroud, Tatiana; von Und Zu Fraunberg, Mikael; Friedrich, Christoph M; Gaál, Emília I; Gottesman, Omri; Guo, Dong-Chuan; Harrison, Seamus C; Hernesniemi, Juha; Hofman, Albert; Inoue, Ituro; Jääskeläinen, Juha E; Jones, Gregory T; Kiemeney, Lambertus A L M; Kivisaari, Riku; Ko, Nerissa; Koskinen, Seppo; Kubo, Michiaki; Kullo, Iftikhar J; Kuivaniemi, Helena; Kurki, Mitja I; Laakso, Aki; Lai, Dongbing; Leal, Suzanne M; Lehto, Hanna; LeMaire, Scott A; Low, Siew-Kee; Malinowski, Jennifer; McCarty, Catherine A; Milewicz, Dianna M; Mosley, Thomas H; Nakamura, Yusuke; Nakaoka, Hirofumi; Niemelä, Mika; Pacheco, Jennifer; Peissig, Peggy L; Pera, Joanna; Rasmussen-Torvik, Laura; Ritchie, Marylyn D; Rivadeneira, Fernando; van Rij, Andre M; Santos-Cortez, Regie Lyn P; Saratzis, Athanasios; Slowik, Agnieszka; Takahashi, Atsushi; Tromp, Gerard; Uitterlinden, André G; Verma, Shefali S; Vermeulen, Sita H; Wang, Gao T; Han, Buhm; Rinkel, Gabriël J E; de Bakker, Paul I W

    2016-01-01

    BACKGROUND: Intracranial aneurysms (IAs), abdominal aortic aneurysms (AAAs), and thoracic aortic aneurysms (TAAs) all have a familial predisposition. Given that aneurysm types are known to co-occur, we hypothesized that there may be shared genetic risk factors for IAs, AAAs, and TAAs. METHODS AND

  16. Shared genetic risk factors of intracranial, abdominal, and thoracic aneurysms

    NARCIS (Netherlands)

    van 't Hof, Femke N G; Ruigrok, Ynte M; Lee, Cue Hyunkyu; Ripke, Stephan; Anderson, Graig; de Andrade, Mariza; Baas, Annette F; Blankensteijn, Jan D; Böttinger, Erwin P; Bown, Matthew J; Broderick, Joseph; Bijlenga, Philippe; Carrell, David S; Crawford, Dana C; Crosslin, David R; Ebeling, Christian; Eriksson, Johan G; Fornage, Myriam; Foroud, Tatiana; von Und Zu Fraunberg, Mikael; Friedrich, Christoph M; Gaál, Emília I; Gottesman, Omri; Guo, Dong-Chuan; Harrison, Seamus C; Hernesniemi, Juha; Hofman, Albert; Inoue, Ituro; Jääskeläinen, Juha E; Jones, Gregory T; Kiemeney, Lambertus A L M; Kivisaari, Riku; Ko, Nerissa; Koskinen, Seppo; Kubo, Michiaki; Kullo, Iftikhar J; Kuivaniemi, Helena; Kurki, Mitja I; Laakso, Aki; Lai, Dongbing; Leal, Suzanne M; Lehto, Hanna; LeMaire, Scott A; Low, Siew-Kee; Malinowski, Jennifer; McCarty, Catherine A; Milewicz, Dianna M; Mosley, Thomas H; Nakamura, Yusuke; Nakaoka, Hirofumi; Niemelä, Mika; Pacheco, Jennifer; Peissig, Peggy L; Pera, Joanna; Rasmussen-Torvik, Laura; Ritchie, Marylyn D; Rivadeneira, Fernando; van Rij, Andre M; Santos-Cortez, Regie Lyn P; Saratzis, Athanasios; Slowik, Agnieszka; Takahashi, Atsushi; Tromp, Gerard; Uitterlinden, André G; Verma, Shefali S; Vermeulen, Sita H; Wang, Gao T; Han, Buhm; Rinkel, Gabriël J E; de Bakker, Paul I W

    2016-01-01

    Background--Intracranial aneurysms (IAs), abdominal aortic aneurysms (AAAs), and thoracic aortic aneurysms (TAAs) all have a familial predisposition. Given that aneurysm types are known to co-occur, we hypothesized that there may be shared genetic risk factors for IAs, AAAs, and TAAs. Methods and

  17. Depiction of the thoracic duct by magnetic resonance imaging. Comparison between magnetic resonance imaging and the anatomical literature

    International Nuclear Information System (INIS)

    Okuda, Itsuko; Udagawa, Harushi; Hirata, Kazuaki; Nakajima, Yasuo

    2011-01-01

    The aim of this study was to compare thoracic duct (TD) configuration depicted by magnetic resonance imaging (MRI) with TD configuration described in the anatomical literature. MRI Scans were acquired with a three-dimensional T2-weighted turbo spin echo (TSE) MRI with a two-dimensional prospective acquisition correction (PACE) technique in 63 patients. We found with MRI that TD displacement occurred more on the left side than that reported in the anatomical literature, and this tendency was more marked in elderly patients. In patients with marked leftward TD displacement, the TD configuration on MRI was compared to the descending aortic configuration on chest radiography. The degree of correspondence between the MRI findings and the anatomical literature was assessed by a χ 2 goodness-of-fit test, and P<0.05 indicated a significant difference. The degree of similarity was determined between TD configuration and aortic configuration by Kendall's coefficient of concordance (W). On MRI scans the TD was often located to the left of the mid-vertebral line compared to the location reported in the anatomical literature (P<0.001). Nine patients had marked leftward TD displacement, a configuration similar to that of the descending aorta (W=1); however, no association with age was established. The TD configuration depicted by MRI differed from that described in the anatomical literature. (author)

  18. Multiple Re-entry Closures After TEVAR for Ruptured Chronic Post-dissection Thoraco-abdominal Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    R. Kinoshita

    Full Text Available Introduction: Although thoracic endovascular aortic repair (TEVAR has become a promising treatment for complicated acute type B dissection, its role in treating chronic post-dissection thoraco-abdominal aortic aneurysm (TAA is still limited owing to persistent retrograde flow into the false lumen (FL through abdominal or iliac re-entry tears. Report: A case of chronic post-dissection TAA treatment, in which a dilated descending FL ruptured into the left thorax, is described. The primary entry tear was closed by emergency TEVAR and multiple abdominal re-entries were closed by EVAR. In addition, major re-entries at the detached right renal artery and iliac bifurcation were closed using covered stents. To close re-entries as far as possible, EVAR was carried out using the chimney technique, and additional aortic extenders were placed above the coeliac artery. A few re-entries remained, but complete FL thrombosis of the rupture site was achieved. Follow-up computed tomography showed significant shrinkage of the FL. Discussion: In treating post-dissection TAA, entry closure by TEVAR is sometimes insufficient, owing to persistent retrograde flow into the FL from abdominal or iliac re-entries. Adjunctive techniques are needed to close these distal re-entries to obtain complete FL exclusion, especially in rupture cases. Recently, encouraging results of complete coverage of the thoraco-abdominal aorta with fenestrated or branched endografts have been reported; however, the widespread employment of such techniques appears to be limited owing to technical difficulties. The present method with multiple re-entry closures using off the shelf and immediately available devices is an alternative for the endovascular treatment of post-dissection TAA, especially in the emergency setting. Keywords: Aortic dissection, Ruptured aortic aneurysm, Post-dissection thoracoabdominal aortic aneurysm, Endovascular aortic repair, Reentry closure, Endovascular procedures

  19. MRI evaluation of the aortic disease

    International Nuclear Information System (INIS)

    Kapuscinski, O.; Polkowski, J.; Zaleska, T.; Walecki, J.; Biesiadko, M.

    1994-01-01

    The goal of our study was to establish the value of MRI in diagnosing aortic disease. During 3 years period 46 patients were examined (12 women aged from 6 to 62 years and 34 men aged from 8 to 72 years). In 28 cases the thoracic aorta was examined, in 6 cases the abdominal aorta and in 12 - both the thoracic and the abdominal aorta. MR images were performed on MRT 50 A Toshiba unit 0.5 T. MR images demonstrated aortic aneurysm (caused by atherosclerosis or trauma), aortic dissections, aortic anomalies (i.e. in Turner syndrome) and non-specific aortitis and vasculitis. We regard MRI as preferable noninvasive imaging technique in diagnosing aortic disease. (author)

  20. Relation between thoracic aortic inflammation and features of plaque vulnerability in the coronary tree in patients with non-ST-segment elevation acute coronary syndrome undergoing percutaneous coronary intervention. An FDG-positron emission tomography and optical coherence tomography study

    Energy Technology Data Exchange (ETDEWEB)

    Taglieri, Nevio; Ghetti, Gabriele; Saia, Francesco; Bacchi Reggiani, Maria Letizia; Rapezzi, Claudio [Alma Mater Studiorum Universita di Bologna, Istituto di Cardiologia, Dipartimento di Medicina Specialistica, Diagnostica e Sperimentale, Bologna (Italy); Nanni, Cristina; Bonfiglioli, Rachele; Lima, Giacomo Maria; Fanti, Stefano [Alma Mater Studiorum Universita di Bologna, Istituto di Medicina Nucleare, Dipartimento di Medicina Specialistica, Diagnostica e Sperimentale, Bologna (Italy); Marco, Valeria [CLI Foundation, Rome (Italy); Prati, Francesco [CLI Foundation, Rome (Italy); Ettore Sansavini Health Science Foundation, GVM Care and Research, Cotignola (Italy)

    2017-10-15

    To evaluate the relationship between aortic inflammation as assessed by {sup 18}F-fluorodeoxyglucose-positron emission tomography ({sup 18}F-FDG-PET) and features of plaque vulnerability as assessed by frequency domain-optical coherence tomography (FD-OCT). We enrolled 30 consecutive non-ST-segment elevation acute coronary syndrome patients undergoing percutaneous coronary intervention. All patients underwent three-vessel OCT before intervention and {sup 18}F-FDG-PET before discharge. Univariable and C-reactive protein (CRP)-adjusted linear regression analyses were performed between features of vulnerability [namely:lipid-rich plaques with and without macrophages and thin cap fibroatheromas (TCFA)] and {sup 18}F-FDG uptake in both ascending (AA) and descending aorta (DA) [measured either as averaged mean and maximum target-to-blood ratio (TBR) or as active slices (TBR{sub max} ≥ 1.6)]. Mean age was 62 years, and 26 patients were male. On univariable linear regression analysis TBR{sub mean} and TBR{sub max} in DA was associated with the number of lipid-rich plaques (β = 4.22; 95%CI 0.05-8.39; p = 0.047 and β = 3.72; 95%CI 1.14-6.30; p = 0.006, respectively). TBR{sub max} in DA was also associated with the number of lipid-rich plaques containing macrophages (β = 2.40; 95%CI 0.07-4.72; p = 0.044). A significant CRP adjusted linear association between the TBR{sub max} in DA and the number of lipid-rich plaques was observed (CRP-adjusted β = 3.58; 95%CI -0.91-6.25; p = 0.01). TBR{sub max} in DA showed a trend towards significant CRP-adjusted association with number of lipid-rich plaques with macrophages (CRP-adjusted β = 2.30; 95%CI -0.11-4.71; p = 0.06). We also observed a CRP-adjusted (β = 2.34; 95%CI 0.22-4.47; p = 0.031) linear association between the number of active slices in DA and the number of lipid-rich plaques. No relation was found between FDG uptake in the aorta and the number of TCFAs. In patients with first NSTEACS{sup ,} {sup 18}F-FDG uptake in

  1. Aortic insufficiency

    Science.gov (United States)

    ... page, please enable JavaScript. Aortic insufficiency is a heart valve disease in which the aortic valve does not close ... aortic insufficiency Images Aortic insufficiency References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ...

  2. Thoracic Trauma.

    Science.gov (United States)

    Dennis, Bradley M; Bellister, Seth A; Guillamondegui, Oscar D

    2017-10-01

    Management of chest trauma is integral to patient outcomes owing to the vital structures held within the thoracic cavity. Understanding traumatic chest injuries and appropriate management plays a pivotal role in the overall well-being of both blunt and penetrating trauma patients. Whether the injury includes rib fractures, associated pulmonary injuries, or tracheobronchial tree injuries, every facet of management may impact the short- and long-term outcomes, including mortality. This article elucidates the workup and management of the thoracic cage, pulmonary and tracheobronchial injuries. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Thoracic CT findings at hypovolemic shock

    International Nuclear Information System (INIS)

    Rotondo, A.; Angelelli, G.; Catalano, O.; Grassi, R.; Scialpi, M.

    1998-01-01

    Purpose: To describe and discuss the thoracic CT features of hypovolemic shock. Material and Methods: From a group of 18 patients with signs of hypovolemia on contrast-enhanced abdominal CT, 11 were selected for our study as having also undergone a complete chest examination. Pulse rate, blood pressure, trauma score value, Glasgow coma scale value, surgical result, and final outcome were retrospectively evaluated. The CT features analyzed were: decreased cardiac volume, reduced caliber of the thoracic aorta, aortic branches and caval venous system, increased enhancement of the aorta, and increased enhancement of the pulmonary collapses/contusions. Results: All 11 subjects presented severe injuries and hemodynamic instability; 7 were stable enough to undergo surgery; only 1 of the 11 survived. Two patients showed none of the features of thoracic hypovolemia. All the other patients presented at least two signs: reduced caliber of the thoracic aorta in 7 cases; decreased volume of the cardiac chambers and increased aortic enhancement in 6; decreased caliber of the aortic vessels in 4; decreased caliber of the caval veins in 3; and increased enhancement of the pulmonary collapses/contusions in 3. Conclusions: In patients with hypovolemia, CT may show several thoracic findings in addition to abdominal ones. Knowledge of these features is important for distinguishing them from traumatic injuries. (orig.)

  4. Inclusion of Functional Status Measures in the Risk Adjustment of 30-Day Mortality After Transcatheter Aortic Valve Replacement: A Report From the Society of Thoracic Surgeons/American College of Cardiology TVT Registry.

    Science.gov (United States)

    Arnold, Suzanne V; O'Brien, Sean M; Vemulapalli, Sreekanth; Cohen, David J; Stebbins, Amanda; Brennan, J Matthew; Shahian, David M; Grover, Fred L; Holmes, David R; Thourani, Vinod H; Peterson, Eric D; Edwards, Fred H

    2018-03-26

    The aim of this study was to develop and validate a risk adjustment model for 30-day mortality after transcatheter aortic valve replacement (TAVR) that accounted for both standard clinical factors and pre-procedural health status and frailty. Assessment of risk for TAVR is important both for patient selection and provider comparisons. Prior efforts for risk adjustment have focused on in-hospital mortality, which is easily obtainable but can be biased because of early discharge of ill patients. Using data from patients who underwent TAVR as part of the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry (June 2013 to May 2016), a hierarchical logistic regression model to estimate risk for 30-day mortality after TAVR based only on pre-procedural factors and access site was developed and internally validated. The model included factors from the original TVT Registry in-hospital mortality model but added the Kansas City Cardiomyopathy Questionnaire (health status) and gait speed (5-m walk test). Among 21,661 TAVR patients at 188 sites, 1,025 (4.7%) died within 30 days. Independent predictors of 30-day death included older age, low body weight, worse renal function, peripheral artery disease, home oxygen, prior myocardial infarction, left main coronary artery disease, tricuspid regurgitation, nonfemoral access, worse baseline health status, and inability to walk. The predicted 30-day mortality risk ranged from 1.1% (lowest decile of risk) to 13.8% (highest decile of risk). The model was able to stratify risk on the basis of patient factors with good discrimination (C = 0.71 [derivation], C = 0.70 [split-sample validation]) and excellent calibration, both overall and in key patient subgroups. A clinical risk model was developed for 30-day death after TAVR that included clinical data as well as health status and frailty. This model will facilitate tracking outcomes over time as TAVR expands to lower risk patients and

  5. Total aortic arch replacement with the elephant trunk technique: single-centre 30-year results.

    Science.gov (United States)

    Shrestha, Malakh; Martens, Andreas; Krüger, Heike; Maeding, Illona; Ius, Fabio; Fleissner, Felix; Haverich, Axel

    2014-02-01

    The combined disease of the aortic arch and the descending aorta (aneurysms and dissection) remains a surgical challenge. Various approaches have been used to treat this complex pathology. In the two-stage operation, at the first-stage operation, the aortic arch is replaced through a median sternotomy. Later, at the second-stage operation, the descending thoracic aorta is replaced through a lateral thoracotomy. The elephant trunk (ET) technique was introduced by H.G. Borst at our centre in March 1982, greatly simplifying the second-phase operation. We present our 30-year experience. From March 1982 to March 2012, 179 patients (112 males, age 56.4±12.6 years) received an ET procedure for the combined disease of the aortic arch and the descending aorta (91 aneurysms, 88 dissections (47 acute)). Fifty-six of these patients had undergone previous cardiac operations. Concomitant procedures were performed if necessary. The cerebral protection was done either by deep (till 1999) or moderate hypothermic circulatory arrest and selective antegrade cerebral perfusion (SACP, after 1999). Cardiopulmonary bypass (CPB) and X-clamp times were 208.5±76.5 min and 123.7±54.8 min, respectively. The intraoperative mortality and 30-day mortality during the first-stage operation were 1.7% (3/179) and 17.3% (31/179, 15 with AADA), respectively. Perioperative stroke was 7.9% (n=14/176). Postoperative recurrent nerve palsy was present in 18.2% (32/176) and paraplegia in 5.6% (10/176). The second-stage completion operation was performed as early as possible. Fifty-seven second-stage completion procedures were performed, either surgically (n=50) or through interventional techniques (n=7). The intraoperative and 30-day mortality after the second-stage completion procedures were 5.2% (3/57) and 7.0% (4/57), respectively. The stroke, recurrent nerve palsy and paraplegia rates were 0, 0 and 7% (4/54), respectively. The ET technique has greatly facilitated the two-stage approach to the surgical

  6. Standing tall after DeBakey Type I aortic dissection extending to left iliac artery

    Science.gov (United States)

    Natarajan, Deepak; Natarajan, Nalin

    2015-01-01

    This report describes DeBakey Type I aortic dissection in a middle-aged hypertensive female who had undergone mitral tissue valve replacement a decade previously. The patient had severe abrupt onset tearing pain in her throat, back, and chest, for which she got admitted in a community hospital, where because of no changes in her ECG and biomarkers, the dissection of aorta was missed. She was subjected to coronary angiography more than 6 weeks later for pain in her left shoulder, which demonstrated normal vessels. She then underwent multi-detector computerised tomography aortogram (MD CTA) that revealed aortic dissection involving ascending, the arch, and descending thoracic and abdominal aorta. The patient declined surgical intervention and has been provided medical therapy in the form of high dose oral beta-blocker and losartan. The patient continues to be stable for the past 18 weeks since the index event. The report highlights the importance of detecting aortic dissection by keeping high index of clinical suspicion in a patient with abrupt onset tearing pain in the throat/back and employment of MD CTA. PMID:26702700

  7. Standing tall after DeBakey Type I aortic dissection extending to left iliac artery

    Directory of Open Access Journals (Sweden)

    Deepak Natarajan

    2015-11-01

    Full Text Available This report describes DeBakey Type I aortic dissection in a middle-aged hypertensive female who had undergone mitral tissue valve replacement a decade previously. The patient had severe abrupt onset tearing pain in her throat, back, and chest, for which she got admitted in a community hospital, where because of no changes in her ECG and biomarkers, the dissection of aorta was missed. She was subjected to coronary angiography more than 6 weeks later for pain in her left shoulder, which demonstrated normal vessels. She then underwent multi-detector computerised tomography aortogram (MD CTA that revealed aortic dissection involving ascending, the arch, and descending thoracic and abdominal aorta. The patient declined surgical intervention and has been provided medical therapy in the form of high dose oral beta-blocker and losartan. The patient continues to be stable for the past 18 weeks since the index event. The report highlights the importance of detecting aortic dissection by keeping high index of clinical suspicion in a patient with abrupt onset tearing pain in the throat/back and employment of MD CTA.

  8. Descendants of the Chiral Anomaly

    OpenAIRE

    Jackiw, R.

    2000-01-01

    Chern-Simons terms are well-known descendants of chiral anomalies, when the latter are presented as total derivatives. Here I explain that also Chern-Simons terms, when defined on a 3-manifold, may be expressed as total derivatives.

  9. Descending perineum syndrome: new perspectives.

    Science.gov (United States)

    Pucciani, F

    2015-08-01

    The classical clinical profile of descending perineum syndrome (DPS) has been replaced by new pathophysiological, diagnostic, and therapeutic acquisitions. This paper will focus on trigger factors ranging from dyssynergic defecation to excessive straining, fecal incontinence against the backdrop of obstructed defecation, attendant rectal diseases, and therapy tailored to evolving stages of DPS.

  10. RELEVANCIA DEL DIAGNÓSTICO DIFERENCIAL ENTRE EL SÍNDROME AÓRTICO AGUDO Y EL SÍNDROME CORONARIO AGUDO EN PACIENTES CON DOLOR TORÁCICO Y CRISIS HIPERTENSIVA: REVISIÓN A PROPÓSITO DE 2 CASOS / Relevance of the differential diagnosis between acute aortic syndrome and acute coronary syndrome in patients with thoracic pain and hypertensive crisis: review on 2 case reports

    Directory of Open Access Journals (Sweden)

    Borja Simó Sánchez

    2011-11-01

    Full Text Available Acute aortic syndrome is a pathological process with low incidence compared with acute coronary syndrome, although with a worse prognosis in the short term, which is why its early diagnosis and urgent treatment are essential to the favorable evolution of thepatient. Electrocardiographic changes suggestive of myocardial ischemia, with acute evolution, are rare in acute aortic syndrome. Even in the presence of a suggestive thoracic pain and high levels of blood pressure, an adequate differential diagnosis is of utmost importance, since the administration of anticoagulation and antiplatelet therapy in high doses can have a dramatic impact on patient outcome. Two cases are presented in which electrocardiographic changes determined the action to take in patients with acute aortic syndrome.

  11. Thoracic CT in the ED: a study of thoracic computed tomography utilisation.

    LENUS (Irish Health Repository)

    Williams, E

    2010-02-01

    The aim of this retrospective study was to investigate the use of thoracic Computed Tomography (CT) in the Emergency Department of a Dublin Academic Teaching Hospital over a six month period. Data was retrieved using the hospital\\'s computerised information system. There were 202 referrals in total for thoracic CT from the Emergency Department during this time period. The most common indication for thoracic CT referral was for the investigation of pulmonary embolism with 127 (63%) referrals. There were 40 (25%) referrals for suspected malignancy and lung disease, whilst 8 (4%) of the referrals were for investigation of thoracic aortic dissection, 8 (4%) for infection, and 6 (3%) were for investigation of thoracic injury. Only 8 (4%) of all referrals were for investigation of injury as a result of chest trauma.

  12. Single-center mid-term experience with chimney-graft technique for the preservation of flow to the supra-aortic branches.

    Science.gov (United States)

    Shahverdyan, Robert; Mylonas, Spyridon; Gawenda, Michael; Brunkwall, Jan

    2018-04-01

    Objectives To investigate the feasibility and the mid-term outcomes of the chimney-graft technique for the revascularization of supra-aortic branches in patients with thoracic aortic pathologies involving the aortic arch. Methods A retrospective analysis of a prospectively maintained database between January 2010 and July 2016 was performed. Primary endpoints were 30-day and overall mortality. Secondary endpoints were technical success, target vessel patency, stroke/transitory ischemic attack and type I/III endoleak rate. Results A total of 30 patients (80% male, median age 70.0 years) were treated using the chimney-graft technique for the supra-aortic branches. The indication was a degenerative aneurysm in nine patients (32%) and a type B Stanford aortic dissection and a penetrating aortic ulcer in the descending aorta in seven patients (23%), respectively. In six patients (20.0%), the indication was an type Ia endoleak after previous endovascular thoracic repair, whereas a pseudoaneurysm after previous open repair of the descending aorta was the indication in one patient (3%). Twenty-three patients (77%) were treated electively, five (17%) emergently and two (7%) urgently because of free rupture. Technical success was achieved in 90% of patients. The 30-day/in-hospital mortality was 17% (5/30). A retrograde dissection was presented in five patients. Four patients experienced a cerebrovascular event. Eight patients had type Ia endoleak and 10 had type II. During the median follow-up of 16 months (range: 0-56), four further patients died: one in respiratory insufficiency, one due to a ruptured abdominal aortic aneurysm, one in meningitis and the last one for unknown reason. The chimney-graft patency was 100%. According to the Kaplan-Meier curve, the estimated survival at one year was 66 ± 9%. Conclusions The chimney-graft technique, despite a technically demanding strategy, is a useful tool as bailout procedure in our armamentarium for high-risk patients

  13. Differences in aortic vortex flow pattern between normal and patients with stroke: qualitative and quantitative assessment using transesophageal contrast echocardiography.

    Science.gov (United States)

    Son, Jang-Won; Hong, Geu-Ru; Hong, Woosol; Kim, Minji; Houle, Helene; Vannan, Mani A; Pedrizzetti, Gianni; Chung, Namsik

    2016-06-01

    The flow in the aorta forms a vortex, which is a critical determinant of the flow dynamics in the aorta. Arteriosclerosis can alter the blood flow pattern of the aorta and cause characteristic alterations of the vortex. However, this change in aortic vortex has not yet been studied. This study aimed to characterize aortic vortex flow pattern using transesophageal contrast echocardiography in normal and stroke patients. A total of 85 patients who diagnosed with ischemic stroke and 16 normal controls were recruited for this study. The 16 normal control subjects were designated as the control group, and the 85 ischemic stroke patients were designated as the stroke group. All subjects underwent contrast transesophageal echocardiography (TEE), and particle image velocimetry was used to assess aortic vortex flow. Qualitative and quantitative analyses of vortex flow morphology, location, phasic variation, and pulsatility were undertaken and compared between the groups. In the control group, multiple irregularly-shaped vortices were observed in a peripheral location in the descending thoracic aorta. In contrast, the stroke group had a single, round, merged, and more centrally located aortic vortex flow. In the quantitative analysis of vortex, vortex depth, which represents the location of the major vortex in the aorta, was significantly higher in the control group than in the stroke group (0.599 ± 0.159 vs. 0.522 ± 0.101, respectively, P = 0.013). Vortex relative strength, which is the pulsatility parameter of the vortex itself, was significantly higher in the stroke group than in the control group (0.367 ± 0.148 vs. 0.304 ± 0.087, respectively, P = 0.025). It was feasible to visualize and quantify the characteristic morphology and pulsatility of the aortic vortex flow using contrast TEE, and aortic vortex pattern significantly differed between normal and stroke patients.

  14. Reduction of transmural 125I-albumin concentration in rat aortic media by chronic hypertension

    International Nuclear Information System (INIS)

    Belmin, J.; Michel, J.B.; Curmi, P.A.; Salzmann, J.L.; Juan, L.; Tedgui, A.

    1991-01-01

    Relative 125I-albumin concentration was measured in vivo in the aortic media of sham-operated (n = 10) and hypertensive (two-kidney, one clip) rats, untreated (n = 8) or treated (n = 10) by an angiotensin converting enzyme inhibitor (CEI, Trandolapril). Blood pressure was acutely lowered to a normal level at the time of the experiment in hypertensive rats (n = 7) to separate the direct effect of increased pressure from the effect of pressure-induced structural changes. Relative tissue concentration profiles of labeled albumin across the media were obtained using a serial frozen-sectioning technique. In hypertensive rats, the mean medial albumin concentration decreased by 35% in the ascending arch and 32% in the descending arch (p less than 0.01). When blood pressure was acutely lowered in hypertensive animals, this value decreased further by 56% in the ascending arch, 48% in the descending arch (p less than 0.01), and 22% in the thoracic aorta (p less than 0.05) as compared with controls. The medial thickness in hypertensive rats was significantly increased (more in the ascending arch than in the rest of the aorta). Four-week CEI treatment reversed hypertension and medial thickening, but the mean medial albumin concentration remained significantly lower in the arch (by 36% in the ascending part and 40% in the descending part, p less than 0.01). The collagen content in the thoracic aorta was significantly increased in hypertensive rats (by 40%, p less than 0.01) and remained increased (by 29%, p less than 0.01) after CEI treatment. These results suggested that the hypertension-induced structural changes might reduce the medial distribution volume for albumin, whereas elevated blood pressure per se tended to enhance albumin concentration within the media

  15. Vascular geometry as a risk factor for non-penetrating traumatic injuries of the aortic arch.

    Directory of Open Access Journals (Sweden)

    Andreas Schicho

    Full Text Available To assess biomechanical factors in aortic arch geometry contributing to the development of non-penetrating aortic arch injury (NAAI in multiply injured patients with an Injury Severity Score (ISS ≥ 16.230 consecutive multiply injured trauma patients with an ISS ≥ 16 admitted to our Level-I trauma center during a consecutive 24-month period were prospectively included of whom 13 presented with NAAI (5.7%. Standardized whole-body CT in a 2x128-detector-row scanner included a head-and-neck CTA. Aortic arch diameters, width, height, angles and thoracic width and height were measured in individuals with NAAI and ISS-, sex-, age-, and trauma mechanism-matched controls.There was no difference between groups regarding sex, age, ISS, and aortic diameters. The aortic arch angle in individuals with NAAI (71.3° ± 14.9° was larger than in healthy control (60.7° ± 8.6°; p*<0.05. In patients with NAAI, the distance between ascendent and descendent aorta was larger (5.2 cm ± 1.9 cm than in control (2.8 ± 0.5 cm; ***p<0.001. The aortic arch is higher above tracheal bifurcation in NAAI (3.6 cm ± 0.6 cm than in matched control (2.4 cm ± 0.3 cm; ***p<0.001. Accordingly, the area under the aortic arch, calculated as half of an eliptic shape, is significantly larger in patients with NAAI (15.0 cm2 ± 6.5 cm2 when compared to age- and sex-matched controls without NAAI (5.5 cm2 ± 1.3 cm2; ***p<0.001.Besides the magnitude of deceleration and direction of impact, width and height of the aortic arch are the 3rd and 4th factor directly contributing to the risk of developing traumatic NAAI in severely injured patients.

  16. Gadolinium-enhanced MR angiography (Gd-MRA) of thoracic vasculature in an animal model using double-dose gadolinium and quiet breathing

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, R.J.; Strouse, P.J. [Section of Pediatric Radiology, University of Michigan Health System, Ann Arbor (United States); Londy, F.J. [Dept. of Radiology, University of Michigan Hospitals, Ann Arbor, MI (United States); Wakefield, T.W. [Dept. of Surgery, Section of Vascular Surgery, University of Michigan Hospitals, Ann Arbor, MI (United States)

    2001-08-01

    Objective. To evaluate a gadolinium-enhanced MR angiography (Gd-MRA) imaging protocol for the assessment of thoracic vessels using double-dose gadolinium and quiet breathing. An animal model was used to simulate imaging in infants and young children. Material and methods. Six baboons (Papio anubis), mean weight 5.7 kg, were sedated and intubated. After the injection of double-dose Gd-DTPA (0.2 mmol/kg) through a peripheral vein, a coronal spoiled 3D gradient-echo volume acquisition was obtained during quiet breathing. Two radiologists reviewed the images for visualization of aortic arch, brachiocephalic vessel origins, pulmonary arteries (central, upper lobe and descending branches), and pulmonary veins (upper and lower). Results. Visualization was excellent for the aortic arch, brachiocephalic vessel origins, and pulmonary arteries, including the hilar branches. Visualization was excellent for the lower and right upper pulmonary veins and fair for the left upper pulmonary vein. There was excellent agreement between radiologists. Conclusion. Imaging of thoracic vessels with Gd-MRA using double gadolinium during quiet breathing was effective in our animal model. The advantages of this technique include a short imaging time and depiction of vascular segments - branches of pulmonary arteries and intraparenchymal segments of pulmonary veins - not optimally visualized with other non-invasive imaging techniques. (orig.)

  17. Gadolinium-enhanced MR angiography (Gd-MRA) of thoracic vasculature in an animal model using double-dose gadolinium and quiet breathing

    International Nuclear Information System (INIS)

    Hernandez, R.J.; Strouse, P.J.; Londy, F.J.; Wakefield, T.W.

    2001-01-01

    Objective. To evaluate a gadolinium-enhanced MR angiography (Gd-MRA) imaging protocol for the assessment of thoracic vessels using double-dose gadolinium and quiet breathing. An animal model was used to simulate imaging in infants and young children. Material and methods. Six baboons (Papio anubis), mean weight 5.7 kg, were sedated and intubated. After the injection of double-dose Gd-DTPA (0.2 mmol/kg) through a peripheral vein, a coronal spoiled 3D gradient-echo volume acquisition was obtained during quiet breathing. Two radiologists reviewed the images for visualization of aortic arch, brachiocephalic vessel origins, pulmonary arteries (central, upper lobe and descending branches), and pulmonary veins (upper and lower). Results. Visualization was excellent for the aortic arch, brachiocephalic vessel origins, and pulmonary arteries, including the hilar branches. Visualization was excellent for the lower and right upper pulmonary veins and fair for the left upper pulmonary vein. There was excellent agreement between radiologists. Conclusion. Imaging of thoracic vessels with Gd-MRA using double gadolinium during quiet breathing was effective in our animal model. The advantages of this technique include a short imaging time and depiction of vascular segments - branches of pulmonary arteries and intraparenchymal segments of pulmonary veins - not optimally visualized with other non-invasive imaging techniques. (orig.)

  18. Analysis of the thoracic aorta using a semi-automated post processing tool

    International Nuclear Information System (INIS)

    Entezari, Pegah; Kino, Aya; Honarmand, Amir R.; Galizia, Mauricio S.; Yang, Yan; Collins, Jeremy; Yaghmai, Vahid; Carr, James C.

    2013-01-01

    Objective: To evaluates a semi-automated method for Thoracic Aortic Aneurysm (TAA) measurement using ECG-gated Dual Source CT Angiogram (DSCTA). Methods: This retrospective HIPAA compliant study was approved by our IRB. Transaxial maximum diameters of outer wall to outer wall were studied in fifty patients at seven anatomic locations of the thoracic aorta: annulus, sinus, sinotubular junction (STJ), mid ascending aorta (MAA) at the level of right pulmonary artery, proximal aortic arch (PROX) immediately proximal to innominate artery, distal aortic arch (DIST) immediately distal to left subclavian artery, and descending aorta (DESC) at the level of diaphragm. Measurements were performed using a manual method and semi-automated software. All readers repeated their measurements. Inter-method, intra-observer and inter-observer agreements were evaluated according to intraclass correlation coefficient (ICC) and Bland–Altman plot. The number of cases with manual contouring or center line adjustment for the semi-automated method and also the post-processing time for each method were recorded. Results: The mean difference between semi-automated and manual methods was less than 1.3 mm at all seven points. Strong inter-method, inter-observer and intra-observer agreement was recorded at all levels (ICC ≥ 0.9). The maximum rate of manual adjustment of center line and contour was at the level of annulus. The average time for manual post-processing of the aorta was 19 ± 0.3 min, while it took 8.26 ± 2.1 min to do the measurements with the semi-automated tool (Vitrea version 6.0.0.1 software). The center line was edited manually at all levels, with most corrections at the level of annulus (60%), while the contour was adjusted at all levels with highest and lowest number of corrections at the levels of annulus and DESC (75% and 0.07% of the cases), respectively. Conclusion: Compared to the commonly used manual method, semi-automated measurement of vessel dimensions is

  19. Visceral hybrid reconstruction of thoracoabdominal aortic aneurysm after open repair of type a aortic dissection by the Bentall procedure with the elephant trunk technique: A case report

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2014-01-01

    Full Text Available Introduction. Reconstruction of chronic type B dissection and thoracoabdominal aortic aneurysm (TAAA remaining after the emergency reconstruction of the ascending thoracic aorta and aortic arch for acute type A dissection represents one of the major surgical challenges. Complications of chronic type B dissection are aneurysmal formation and rupture of an aortic aneurysm with a high mortality rate. We presented a case of visceral hybrid reconstruction of TAAA secondary to chronic dissection type B after the Bentall procedure with the elephant trunk technique due to acute type A aortic dissection in a high-risk patient. Case report. A 62 year-old woman was admitted to our institution for reconstruction of Crawford type I TAAA secondary to chronic dissection. The patient had had an acute type A aortic dissection 3 years before and undergone reconstruction by the Bentall procedure with the elephant trunk technique with valve replacement. On admission the patient had coronary artery disease (myocardial infarction, two times in the past 3 years, congestive heart disease with ejection fraction of 25% and chronic obstructive pulmonary disease. On computed tomography (CT of the aorta TAAA was revealed with a maximum diameter of 93 mm in the descending thoracic aorta secondary to chronic dissection. All the visceral arteries originated from the true lumen with exception of the celiac artery (CA, and the end of chronic dissection was below the origin of the superior mesenteric artery (SMA. The patient was operated on using surgical visceral reconstruction of the SMA, CA and the right renal artery (RRA as the first procedure. Postoperative course was without complications. Endovascular TAAA reconstruction was performed as the second procedure one month later, when the elephant trunk was used as the proximal landing zone for the endograft, and distal landing zone was the level of origin of the RRA. Postoperatively, the patient had no neurological deficit and

  20. Aortic Disease in the Young: Genetic Aneurysm Syndromes, Connective Tissue Disorders, and Familial Aortic Aneurysms and Dissections

    Directory of Open Access Journals (Sweden)

    Marcelo Cury

    2013-01-01

    Full Text Available There are many genetic syndromes associated with the aortic aneurysmal disease which include Marfan syndrome (MFS, Ehlers-Danlos syndrome (EDS, Loeys-Dietz syndrome (LDS, familial thoracic aortic aneurysms and dissections (TAAD, bicuspid aortic valve disease (BAV, and autosomal dominant polycystic kidney disease (ADPKD. In the absence of familial history and other clinical findings, the proportion of thoracic and abdominal aortic aneurysms and dissections resulting from a genetic predisposition is still unknown. In this study, we propose the review of the current genetic knowledge in the aortic disease, observing, in the results that the causative genes and molecular pathways involved in the pathophysiology of aortic aneurysm disease remain undiscovered and continue to be an area of intensive research.

  1. Aortic dissection involving the brachio-cephalic trunk, celiac trunk, and left common iliac artery with left kidney ischemia: Case report

    International Nuclear Information System (INIS)

    Paslawski, M.; Krzyzanowski, K.

    2006-01-01

    Acute aortic dissection is one of the most dramatic cardiovascular emergencies. To limit the possibility of death, a detailed morphologic and functional diagnosis must be obtained quickly. Aortography has been the traditional method of assessing suspected aortic dissection; however, concern over the low sensitivity of aortography has prompted the investigation of other imaging techniques for this purpose. Transesophageal echocardiography and magnetic resonance imaging are increasingly used in the evaluation of aortic dissection. A recent study found that the sensitivity and specificity of helical computed tomography compare well with those of MR imaging and transesophageal echocardiography. The 55-year-old patient with acute chest and abdominal pain were examined due to suspected aortic dissection. CT examination of thoracic and abdomial aorta was performed. The examination begins with conventional, unenhanced CT. Both unenhanced CT scans and scans after administering of contrast agent were performed. Enhanced images reveal contrast flow in both the false and true aortic lumen. the intima flap in the ascending aorta, aortic arch, and descending aorta, extending to the brachiocephalic trunk, was seen on axial images. In the abdominal aorta, the intimal flap extended to the celiac trunk, without evidence of its occlusion. In one patient, the occlusion of the left renal artery with renal infract was seen on axial images. The intimal flap calcification enables diagnosis even on unenhanced images. The morphology and extent of the dissection was also seen on MPR and VRT images. Helical CT can be used to study the entire aorta in aortic dissection and for follow-up. This technique allows accurate diagnosis of the type of dissection, atypical forms of aortic dissection, and early and late complications after surgery or medical treatment. In addition, helical CT is useful in the surveillance of abdominal branch-vessel compromise, which can be life-threatening in the acute

  2. Aortic reconstruction with bovine pericardial grafts

    Directory of Open Access Journals (Sweden)

    Silveira Lindemberg Mota

    2003-01-01

    Full Text Available INTRODUCTION: Glutaraldehyde-treated crimped bovine pericardial grafts are currently used in aortic graft surgery. These conduits have become good options for these operations, available in different sizes and shapes and at a low cost. OBJECTIVE:To evaluate the results obtained with bovine pericardial grafts for aortic reconstruction, specially concerning late complications. METHOD: Between January 1995 and January 2002, 57 patients underwent different types of aortic reconstruction operations using bovine pericardial grafts. A total of 29 (50.8% were operated on an urgent basis (mostly acute Stanford A dissection and 28 electively. Thoracotomy was performed in three patients for descending aortic replacement (two patients and aortoplasty with a patch in one. All remaining 54 underwent sternotomy, cardiopulmonary bypass and aortic resection. Deep hypothermia and total circulatory arrest was used in acute dissections and arch operations. RESULTS: Hospital mortality was 17.5%. Follow-up was 24.09 months (18.5 to 29.8 months confidence interval and complication-free actuarial survival curve was 92.3% (standard deviation ± 10.6. Two patients lately developed thoracoabdominal aneurysms following previous DeBakey II dissection and one died from endocarditis. One "patch" aortoplasty patient developed local descending aortic pseudoaneurysm 42 months after surgery. All other patients are asymptomatic and currently clinically evaluated with echocardiography and CT scans, showing no complications. CONCLUSION: Use of bovine pericardial grafts in aortic reconstruction surgery is adequate and safe, with few complications related to the conduits.

  3. Diminutive Porcelain Ascending Aorta With Supravalvular Aortic Stenosis.

    Science.gov (United States)

    Houmsse, Mustafa; McDavid, Asia; Kilic, Ahmet

    2018-05-01

    This report describes the case of a 49-year-old man with a medical history significant for congenital aortic stenosis. The patient presented with progressive shortness of breath and decreased stamina and was found to have a concentric, diminutive porcelain ascending aorta with diffuse supravalvular aortic stenosis. We describe treatment with an aortic root augmentation and Bentall procedure using hypothermic circulatory arrest. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  4. The risk for type B aortic dissection in Marfan syndrome.

    Science.gov (United States)

    den Hartog, Alexander W; Franken, Romy; Zwinderman, Aeilko H; Timmermans, Janneke; Scholte, Arthur J; van den Berg, Maarten P; de Waard, Vivian; Pals, Gerard; Mulder, Barbara J M; Groenink, Maarten

    2015-01-27

    Aortic dissections involving the descending aorta are a major clinical problem in patients with Marfan syndrome. The purpose of this study was to identify clinical parameters associated with type B aortic dissection and to develop a risk model to predict type B aortic dissection in patients with Marfan syndrome. Patients with the diagnosis of Marfan syndrome and magnetic resonance imaging or computed tomographic imaging of the aorta were followed for a median of 6 years for the occurrence of type B dissection or the combined end point of type B aortic dissection, distal aortic surgery, and death. A model using various clinical parameters as well as genotyping was developed to predict the risk for type B dissection in patients with Marfan syndrome. Between 1998 and 2013, 54 type B aortic dissections occurred in 600 patients with Marfan syndrome (mean age 36 ± 14 years, 52% male). Independent variables associated with type B aortic dissection were prior prophylactic aortic surgery (hazard ratio: 2.1; 95% confidence interval: 1.2 to 3.8; p = 0.010) and a proximal descending aorta diameter ≥27 mm (hazard ratio: 2.2; 95% confidence interval: 1.1 to 4.3; p = 0.020). In the risk model, the 10-year occurrence of type B aortic dissection in low-, moderate-, and high-risk patients was 6%, 19%, and 34%, respectively. Angiotensin II receptor blocker therapy was associated with fewer type B aortic dissections (hazard ratio: 0.3; 95% confidence interval: 0.1 to 0.9; p = 0.030). Patients with Marfan syndrome with prior prophylactic aortic surgery are at substantial risk for type B aortic dissection, even when the descending aorta is only slightly dilated. Angiotensin II receptor blocker therapy may be protective in the prevention of type B aortic dissections. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Mycotic Aneurysm of the Aortic Arch

    Directory of Open Access Journals (Sweden)

    Ji Hye Seo

    2014-08-01

    Full Text Available A mycotic aneurysm of the thoracic aorta is rare. We report a case of mycotic aneurysm that developed in the aortic arch. An 86-year-old man was admitted with fever and general weakness. Blood culture yielded methicillin-resistant Staphylococcus aureus. Chest X-ray showed an enlarged aortic arch, and computed tomography scan revealed an aneurysm in the aortic arch. The patient was treated only with antibiotics and not surgically. The size of the aneurysm increased rapidly, resulting in bronchial obstruction and superimposed pneumonia. The patient died of respiratory failure.

  6. Unusual rapid evolution of type B aortic dissection in a marfan patient following heart transplantation: successful endovascular treatment.

    Science.gov (United States)

    Botta, L; Russo, V; Grigioni, F; Arpesella, G; Rocchi, G; Di Bartolomeo, R; Fattori, R

    2006-10-01

    A patient with Marfan syndrome with previous Bentall operation for mitral and tricuspid valve repair, required orthotopic cardiac transplantation for end stage cardiomyopathy. Postoperatively he suffered type-B aortic dissection, despite normal aortic diameters. Following sudden increase of aortic diameters, two years later, he underwent successful stent graft implantation. In patients with Marfan syndrome, post transplantation morbidity is high, with a 40% incidence of thoracic aortic dissection. This case highlights the potential of endovascular approach for treating post-transplantation aortic dissection.

  7. Descending necrotising mediastinitis: Case report

    Directory of Open Access Journals (Sweden)

    Canan Eren

    2010-12-01

    Full Text Available Descending necrotising mediastinitis is a rare but usually fatal infection. It commonly results of oropharyngeal and odontogenic infections. Complete recovery may be achieved by early diagnosis, prompt medical and surgical approach. We are reporting our desending necrotizing mediastinitis case secondary to tooth abscess, and it’s successfull surgical treatment.A-48-year-old man admitted with fever, exhaustion neck distendion for a week. He had a tooth abscess one week ago. Chest tomography showed neck and mediastinal air and fluid collections. Antibiothreapy was started and urgent surgical management applied. Neck drainage was performed via transcervical approach. Mediastinal drainage was performed via right thoracotomy. Continue mediastinal washing feasibility was done by drainage tubes. Drainage was ended after nonextra drainage and cultural growthless. Vital signs became stable and control tomography showed complete recovery. He was healthfull at the 6th month’s follow-up.Broad antibiothreapy, surgical management are the main approaches for descending necrotising mediastinitis. The most common surgical procedure is the combination of transcervical approach and thoracotomy. We suggest early and agressive surgical management for the complete recovery. J Clin Exp Invest 2010; 1(3: 228-231

  8. Long-Term Follow-Up After Endovascular Treatment of Acute Aortic Emergencies

    International Nuclear Information System (INIS)

    Pitton, M. B.; Herber, S.; Schmiedt, W.; Neufang, A.; Dorweiler, B.; Dueber, C.

    2008-01-01

    Purpose. To investigate the long-term outcome and efficacy of emergency treatment of acute aortic diseases with endovascular stent-grafts. Methods. From September 1995 to April 2007, 37 patients (21 men, 16 women; age 53.9 ± 19.2 years, range 18-85 years) with acute complications of diseases of the descending thoracic aorta were treated by endovascular stent-grafts: traumatic aortic ruptures (n = 9), aortobronchial fistulas due to penetrating ulcer or hematothorax (n = 6), acute type B dissections with aortic wall hematoma, penetration, or ischemia (n = 13), and symptomatic aneurysm of the thoracic aorta (n = 9) with pain, penetration, or rupture. Diagnosis was confirmed by contrast-enhanced CT. Multiplanar reformations were used for measurement of the landing zones of the stent-grafts. Stent-grafts were inserted via femoral or iliac cut-down. Two procedures required aortofemoral bypass grafting prior to stent-grafting due to extensive arteriosclerotic stenosis of the iliac arteries. In this case the bypass graft was used for introduction of the stent-graft. Results. A total of 46 stent-grafts were implanted: Vanguard/Stentor (n = 4), Talent (n = 31), and Valiant (n = 11). Stent-graft extension was necessary in 7 cases. In 3 cases primary graft extension was done during the initial procedure (in 1 case due to distal migration of the graft during stent release, in 2 cases due to the total length of the aortic aneurysm). In 4 cases secondary graft extensions were performed-for new aortic ulcers at the proximal stent struts (after 5 days) and distal to the graft (after 8 months) and recurrent aortobronchial fistulas 5 months and 9 years after the initial procedure-resulting in a total of 41 endovascular procedures. The 30-day mortality rate was 8% (3 of 37) and the overall follow-up was 29.9 ± 36.6 months (range 0-139 months). All patients with traumatic ruptures demonstrated an immediate sealing of bleeding. Patients with aortobronchial fistulas also demonstrated a

  9. Tratamiento endovascular del aneurisma de aorta descendente en el adolescente con síndrome de Marfan: Reporte de un caso Endovascular treatment of an aneurysm of the descending aorta in an adolescent with Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Juan G Barrera

    2012-01-01

    Full Text Available Se expone el caso de un adolescente de 14 años de edad, con síndrome de Marfan y antecedente de tres cirugías cardiovasculares previas: valvuloplastia aórtica y mitral a los cinco años y valvuloplastia aórtica y reconstrucción de la aorta torácica con tubo de pericardio bovino a sus diez años. En primer tiempo quirúrgico se realizó reemplazo valvular aórtico por válvula mecánica y valvuloplastia mitral y tricuspidea, y en segundo tiempo quirúrgico, durante la misma hospitalización, exclusión endovascular de aneurisma de aorta descendente asintomático sin complicaciones. Antes del egreso se diagnosticó una endofuga tipo II que se manejó con observación clínica. Luego de un año del procedimiento, los controles clínico y tomográfico son satisfactorios.We describe the case of a 14-year-old adolescent with Marfan syndrome and a history of three previous cardiovascular surgeries: aortic and mitral valve replacement at the age of 5 and aortic valve replacement and reconstruction of the thoracic aorta with a tube of bovine pericardium at the age of ten. In the first surgical procedure the aortic valve was replaced by a mechanical valve, and mitral and tricuspid valvuloplasty was performed. In a second surgical procedure during the same hospitalization, endovascular exclusion of the asymptomatic descending aortic aneurysm was realized without complications. Before discharge, a type II endoleak was diagnosed and managed through clinical observation. After a year of the procedure, clinical and tomographic controls are satisfactory.

  10. Spiral CT aortography: an efficient technique for the diagnosis of traumatic aortic injury

    International Nuclear Information System (INIS)

    Wicky, S.; Capasso, P.; Meuli, R.; Schnyder, P.; Fischer, A.; Segesser, L. von

    1998-01-01

    The objective of this study was to assess the efficiency of spiral CT (SCT) aortography for diagnosing acute aortic lesions in blunt thoracic trauma patients. Between October 1992 and June 1997, 487 SCT scans of the chest were performed on blunt thoracic trauma patients. To assess aortic injury, the following SCT criteria were considered: hemomediastinum, peri-aortic hematoma, irregular aspect of the aortic wall, aortic pseudodiverticulum, intimal flap and traumatic dissection. Aortic injury was diagnosed on 14 SCT examinations (2.9 %), five of the patients having had an additional digital aortography that confirmed the aortic trauma. Twelve subjects underwent surgical repair of the thoracic aorta, which in all but one case confirmed the aortic injury. Two patients died before surgery from severe brain lesions. The aortic blunt lesions were confirmed at autopsy. According to the follow-up of the other 473 patients, we are aware of no false-negative SCT examination. Our limited series shows a sensitivity of 100 % and specificity of 99.8 % of SCT aortography in the diagnosis of aortic injury. It is concluded that SCT aortagraphy is an accurate diagnostic method for the assessment of aortic injury in blunt thoracic trauma patients. (orig.)

  11. Dissection of descending aorta treated by stent-graft implantation in a patient with Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Marat A. Aripov

    2017-04-01

    Full Text Available This report describes a 32 years old patient with Marfan syndrome and hypertension. David`s procedure was performed to the patient three months before due to dissection of the ascending thoracic aorta. Computer tomography scan showed DeBakey type III dissection of aorta beginning from left subclavian artery with transition to the ostium of the celiac trunk and proximal part of the left common iliac artery. Stent-grafts in the descending thoracic aorta with overlapping of left subclavian artery were implanted to the patient with Marfan syndrome. Patient was discharged and no complications recorded at 6th month follow-up.

  12. Is there a prospect for hybrid aortic arch surgery?

    Science.gov (United States)

    Bashir, Mohamad; Harky, Amer; Bilal, Haris

    2018-05-16

    The surge of endovascular repair of aortic aneurysm in current modern aortic surgery practice has been the key for surgical management of elective cases of thoracic aortic aneurysms. This has paved way for the combined hybrid approach to be amongst the armamentarium for the management of aortic arch disease. The pivotal understanding of the aortic arch natural history coupled with device technology advancement allowed surgeons insight into delivery of hybrid surgery with acceptable morbidity and mortality results. This review article provides current insights into hybrid technique of aortic arch aneurysm repair and the evidences behind its applicability to arch surgery. It is aimed to highlight the challenges encountered for this innovative approach and correlate its challenges to those that are met by the conventional open aortic arch repair.

  13. Fate of remnant sinuses of Valsalva in patients with bicuspid and trileaflet valves undergoing aortic valve, ascending aorta, and aortic arch replacement.

    Science.gov (United States)

    Milewski, Rita Karianna; Habertheuer, Andreas; Bavaria, Joseph E; Siki, Mary; Szeto, Wilson Y; Krause, Eric; Korutla, Varun; Desai, Nimesh D; Vallabhajosyula, Prashanth

    2017-08-01

    the type of valvular pathology (aortic stenosis vs aortic insufficiency) or valvular morphology (bicuspid aortic valve vs tricuspid aortic valve). Aortic valve replacement with supracoronary ascending aorta replacement may have a stabilizing effect on the sinus segment over long-term follow-up in patients with tricuspid aortic valves or bicuspid aortic valves. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  14. Experiencia en el manejo endovascular para el tratamiento de la aorta torácica Experience in endovascular management for thoracic aorta treatment

    Directory of Open Access Journals (Sweden)

    Juan G Barrera

    2007-12-01

    aneurysm, showing a 16% mortality reduction. Objective: evaluate surgical results in terms of morbid-mortality in patients submitted to endovascular management of thoracic aortic lesions in the Colombian Cardiovascular Foundation from 2003 to 2005. Design-Method: longitudinal descriptive retrospective study in which clinical histories of all patients submitted to endovascular treatment of thoracico-abdominal aortic lesions were evaluated. Only patients with thoracic aortic procedures between 2003 and 2005 were included. Data analysis was realized in Stata/SE 8,0. Results: thoracic aortic procedures were performed in 16 patients. 75% were male with mean age 55.9 ± 12.6 years. 87.5% (14 had type A or B aortic dissection; one patient had traumatic aortic transection and one had aneurysm of thoracic descendant aorta. Acute dissections were presented in 78.6% (11 patients and chronic dissections in 21.4% (3 patients. Average of endoprosthesis employed was 2.8 ± 1. Intensive care unit stay was 3 ± 2.7 days. 81.3% had no mayor complications. Mortality was 18.7% (3 patients. All patients had post-operative computerized tomography scan, with satisfactory evolution. Conclusion: according to the largest casuistics literature reports, endovascular management of dissection, aneurysm or aortic trauma is considered a trustworthy procedure that diminishes morbid-mortality.

  15. Investigation of pulsatile flowfield in healthy thoracic aorta models.

    Science.gov (United States)

    Wen, Chih-Yung; Yang, An-Shik; Tseng, Li-Yu; Chai, Jyh-Wen

    2010-02-01

    Cardiovascular disease is the primary cause of morbidity and mortality in the western world. Complex hemodynamics plays a critical role in the development of aortic dissection and atherosclerosis, as well as many other diseases. Since fundamental fluid mechanics are important for the understanding of the blood flow in the cardiovascular circulatory system of the human body aspects, a joint experimental and numerical study was conducted in this study to determine the distributions of wall shear stress and pressure and oscillatory WSS index, and to examine their correlation with the aortic disorders, especially dissection. Experimentally, the Phase-Contrast Magnetic Resonance Imaging (PC-MRI) method was used to acquire the true geometry of a normal human thoracic aorta, which was readily converted into a transparent thoracic aorta model by the rapid prototyping (RP) technique. The thoracic aorta model was then used in the in vitro experiments and computations. Simulations were performed using the computational fluid dynamic (CFD) code ACE+((R)) to determine flow characteristics of the three-dimensional, pulsatile, incompressible, and Newtonian fluid in the thoracic aorta model. The unsteady boundary conditions at the inlet and the outlet of the aortic flow were specified from the measured flowrate and pressure results during in vitro experiments. For the code validation, the predicted axial velocity reasonably agrees with the PC-MRI experimental data in the oblique sagittal plane of the thoracic aorta model. The thorough analyses of the thoracic aorta flow, WSSs, WSS index (OSI), and wall pressures are presented. The predicted locations of the maxima of WSS and the wall pressure can be then correlated with that of the thoracic aorta dissection, and thereby may lead to a useful biological significance. The numerical results also suggest that the effects of low WSS and high OSI tend to cause wall thickening occurred along the inferior wall of the aortic arch and the

  16. Stroke Volume estimation using aortic pressure measurements and aortic cross sectional area: Proof of concept.

    Science.gov (United States)

    Kamoi, S; Pretty, C G; Chiew, Y S; Pironet, A; Davidson, S; Desaive, T; Shaw, G M; Chase, J G

    2015-08-01

    Accurate Stroke Volume (SV) monitoring is essential for patient with cardiovascular dysfunction patients. However, direct SV measurements are not clinically feasible due to the highly invasive nature of measurement devices. Current devices for indirect monitoring of SV are shown to be inaccurate during sudden hemodynamic changes. This paper presents a novel SV estimation using readily available aortic pressure measurements and aortic cross sectional area, using data from a porcine experiment where medical interventions such as fluid replacement, dobutamine infusions, and recruitment maneuvers induced SV changes in a pig with circulatory shock. Measurement of left ventricular volume, proximal aortic pressure, and descending aortic pressure waveforms were made simultaneously during the experiment. From measured data, proximal aortic pressure was separated into reservoir and excess pressures. Beat-to-beat aortic characteristic impedance values were calculated using both aortic pressure measurements and an estimate of the aortic cross sectional area. SV was estimated using the calculated aortic characteristic impedance and excess component of the proximal aorta. The median difference between directly measured SV and estimated SV was -1.4ml with 95% limit of agreement +/- 6.6ml. This method demonstrates that SV can be accurately captured beat-to-beat during sudden changes in hemodynamic state. This novel SV estimation could enable improved cardiac and circulatory treatment in the critical care environment by titrating treatment to the effect on SV.

  17. Left subclavian artery revascularization as part of thoracic stent grafting

    NARCIS (Netherlands)

    Saouti, N.; Hindori, V.; Morshuis, W.J.; Heijmen, R.H.

    2015-01-01

    OBJECTIVES: Intentional covering of the left subclavian artery (LSA) as part of thoracic endovascular aortic repair (TEVAR) can cause (posterior) strokes or left arm malperfusion. LSA revascularization can be done as prophylaxis against, or as treatment of, these complications. We report our

  18. Aortic stenosis

    Science.gov (United States)

    ... Images Aortic stenosis Heart valves References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ... ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/ ...

  19. Asphyxiating thoracic dysplasia

    International Nuclear Information System (INIS)

    Franzcr, J.; Kozlowski, K.

    2008-01-01

    Asphyxiating Thoracic Dysplasia is the most frequent form of Small Thorax - Short Rib Syndromes. Asphyxiating Thoracic Dysplasia in two patients with different clinical course is reported. Radiographic examination is the only method to diagnose Asphyxiating Thoracic Dysplasia with certainty. The correct diagnosis is important for prognostication and genetic counseling. It also excludes the necessity of further, often expensive investigations. (author)

  20. A Typical Immune T/B Subset Profile Characterizes Bicuspid Aortic Valve: In an Old Status?

    Directory of Open Access Journals (Sweden)

    Carmela R. Balistreri

    2018-01-01

    Full Text Available Bicuspid valve disease is associated with the development of thoracic aortic aneurysm. The molecular mechanisms underlying this association still need to be clarified. Here, we evaluated the circulating levels of T and B lymphocyte subsets associated with the development of vascular diseases in patients with bicuspid aortic valve or tricuspid aortic valve with and without thoracic aortic aneurysm. We unveiled that the circulating levels of the MAIT, CD4+IL−17A+, and NKT T cell subsets were significantly reduced in bicuspid valve disease cases, when compared to tricuspid aortic valve cases in either the presence or the absence of thoracic aortic aneurysm. Among patients with tricuspid aortic valve, these cells were higher in those also affected by thoracic aortic aneurysm. Similar data were obtained by examining CD19+ B cells, naïve B cells (IgD+CD27−, memory unswitched B cells (IgD+CD27+, memory switched B cells (IgD−CD27+, and double-negative B cells (DN (IgD−CD27−. These cells resulted to be lower in subjects with bicuspid valve disease with respect to patients with tricuspid aortic valve. In whole, our data indicate that patients with bicuspid valve disease show a quantitative reduction of T and B lymphocyte cell subsets. Future studies are encouraged to understand the molecular mechanisms underlying this observation and its pathophysiological significance.

  1. Incidence and progression of mild aortic regurgitation after Tirone David reimplantation valve-sparing aortic root replacement.

    Science.gov (United States)

    Stephens, Elizabeth H; Liang, David H; Kvitting, John-Peder Escobar; Kari, Fabian A; Fischbein, Michael P; Mitchell, R Scott; Miller, D Craig

    2014-01-01

    The study objective was to determine whether recurrent or residual mild aortic regurgitation, which occurs after valve-sparing aortic root replacement, progresses over time. Between 2003 and 2008, 154 patients underwent Tirone David-V valve-sparing aortic root replacement; 96 patients (62%) had both 1-year (median, 12 ± 4 months) and mid-term (62 ± 22 months) transthoracic echocardiograms available for analysis. Age of patients averaged 38 ± 13 years, 71% were male, 31% had a bicuspid aortic valve, 41% had Marfan syndrome, and 51% underwent aortic valve repair, predominantly cusp free margin shortening. Forty-one patients (43%) had mild aortic regurgitation on 1-year echocardiogram. In 85% of patients (n = 35), mild aortic regurgitation remained stable on the most recent echocardiogram (median, 57 ± 20 months); progression to moderate aortic regurgitation occurred in 5 patients (12%) at a median of 28 ± 18 months and remained stable thereafter; severe aortic regurgitation developed in 1 patient, eventually requiring reoperation. Five patients (5%) had moderate aortic regurgitation at 1 year, which did not progress subsequently. Two patients (2%) had more than moderate aortic regurgitation at 1 year, and both ultimately required reoperation. Although mild aortic regurgitation occurs frequently after valve-sparing aortic root replacement, it is unlikely to progress over the next 5 years and should not be interpreted as failure of the valve-preservation concept. Further, we suggest that mild aortic regurgitation should not be considered nonstructural valve dysfunction, as the 2008 valve reporting guidelines would indicate. We need 10- to 15-year follow-up to learn the long-term clinical consequences of mild aortic regurgitation early after valve-sparing aortic root replacement. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  2. Avaliação da anastomose de artéria torácica interna esquerda com artéria interventricular anterior pela ecodopplercardiografia Evaluation of left internal thoracic artery anastomosis with left anterior descending coronary artery by Doppler echocardiography

    Directory of Open Access Journals (Sweden)

    Adelaide Arruda

    1997-12-01

    Full Text Available OBJETIVO: Avaliar o valor do ecocardiograma Doppler(ECO transtorácico na identificação de perviabilidade da anastomose entre artéria torácica interna esquerda (ATIE e interventricular anterior, realizada pela técnica de revascularização miocárdica pela minitoracotomia sem circulação extracorpórea. MÉTODOS: Estudaram-se os primeiros 12 pacientes, consecutivos, no período de pós-operatório intra-hospitalar pelo ECO, utilizando-se transdutores de 5MHz, pela via paraesternal esquerda, preferencialmente. Foram analisadas velocidades máximas e integrais de velocidade dos componentes sistólico e diastólico das curvas espectrais de fluxo Doppler. Todos pacientes foram submetidos à cinecoronariografia, enquanto hospitalizados. RESULTADOS: O ECO foi exeqüível em 93% dos pacientes. Nos com anastomose pérvia (6/7, observou-se ao estudo Doppler amplo componente diastólico (padrão A. Naqueles com anastomose obstruída (4/4 o padrão observado foi de predomínio sistólico (padrão B (p=0,003*. CONCLUSÃO: O ECO da ATIE anastomosada com a artéria interventricular anterior, após cirurgia de revascularização miocárdica pela técnica de minitoracotomia, permitiu caracterizar precocemente, com precisão, a perviabilidade da anastomose.PURPOSE: To study the value of Doppler echocardiography as a tool for the evaluation of left internal thoracic artery graft (LITAG patency in patients who underwent coronary revascularization using minimally invasive bypass surgery without extracorporeal circulation. METHODS: The first 12 consecutive patients were studied after coronary artery bypass surgery using a 5MHz Doppler transducer. Doppler signals for the systolic and diastolic flow velocities were preferably obtained in the second intercostal space. All patients underwent coronary angiography while hospitalized. RESULTS: The exam was feasible in 93% of patients. Doppler flow pattern was predominantly diastolic (pattern A in patients with patent

  3. Aortic stenosis and vascular calcifications in alkaptonuria.

    Science.gov (United States)

    Hannoush, Hwaida; Introne, Wendy J; Chen, Marcus Y; Lee, Sook-Jin; O'Brien, Kevin; Suwannarat, Pim; Kayser, Michael A; Gahl, William A; Sachdev, Vandana

    2012-02-01

    Alkaptonuria is a rare metabolic disorder of tyrosine catabolism in which homogentisic acid (HGA) accumulates and is deposited throughout the spine, large joints, cardiovascular system, and various tissues throughout the body. In the cardiovascular system, pigment deposition has been described in the heart valves, endocardium, pericardium, aortic intima and coronary arteries. The prevalence of cardiovascular disease in patients with alkaptonuria varies in previous reports. We present a series of 76 consecutive adult patients with alkaptonuria who underwent transthoracic echocardiography between 2000 and 2009. A subgroup of 40 patients enrolled in a treatment study underwent non-contrast CT scans and these were assessed for vascular calcifications. Six of the 76 patients had aortic valve replacement. In the remaining 70 patients, 12 patients had aortic sclerosis and 7 patients had aortic stenosis. Unlike degenerative aortic valve disease, we found no correlation with standard cardiac risk factors. There was a modest association between the severity of aortic valve disease and joint involvement, however, we saw no correlation with urine HGA levels. Vascular calcifications were seen in the coronaries, cardiac valves, aortic root, descending aorta and iliac arteries. These findings suggest an important role for echocardiographic screening of alkaptonuria patients to detect valvular heart disease and cardiac CT to detect coronary artery calcifications. Published by Elsevier Inc.

  4. Long-Term Risk for Aortic Complications After Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Versus Marfan Syndrome.

    Science.gov (United States)

    Itagaki, Shinobu; Chikwe, Joanna P; Chiang, Yuting P; Egorova, Natalia N; Adams, David H

    2015-06-09

    Bicuspid aortic valves are associated with valve dysfunction, ascending aortic aneurysm and dissection. Management of the ascending aorta at the time of aortic valve replacement (AVR) in these patients is controversial and has been extrapolated from experience with Marfan syndrome, despite the absence of comparative long-term outcome data. This study sought to assess whether the natural history of thoracic aortopathy after AVR in patients with bicuspid aortic valve disease is substantially different from that seen in patients with Marfan syndrome. In this retrospective comparison, outcomes of 13,205 adults (2,079 with bicuspid aortic valves, 73 with Marfan syndrome, and 11,053 control patients with acquired aortic valve disease) who underwent primary AVR without replacement of the ascending aorta in New York State between 1995 and 2010 were compared. The median follow-up time was 6.6 years. The long-term incidence of thoracic aortic dissection was significantly higher in patients with Marfan syndrome (5.5 ± 2.7%) compared with those with bicuspid valves (0.55 ± 0.21%) and control group patients (0.41 ± 0.08%, p Marfan syndrome (10.8 ± 4.4%) compared with those with bicuspid valves (4.8 ± 0.8%) and control group patients (1.4 ± 0.2%) (p Marfan syndrome were significantly more likely to undergo thoracic aortic surgery in late follow-up (10.4 ± 4.3%) compared with those with bicuspid valves (2.5 ± 0.6%) and control group patients (0.50 ± 0.09%) (p Marfan syndrome compared with those with bicuspid aortic valves confirm that operative management of patients with bicuspid aortic valves should not be extrapolated from Marfan syndrome and support discrete treatment algorithms for these different clinical entities. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Relation of aortic calcification, wall thickness, and distensibility with severity of coronary artery disease: evaluation with coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Seonah; Yong, Hwan Seok; Doo, Kyung Won; Kang, Eun-Young; Woo, Ok Hee; Choi, Eun Jung [Dept. of Radiology, Korea Univ. Guro Hospital, Korea Univ. College of Medicine, Seoul (Korea, Republic of)], e-mail: yhwanseok@naver.com

    2012-10-15

    Background Three known risk factors for aortic atherosclerosis predict the severity of coronary artery disease (CAD): aortic calcification (AC), aortic wall thickness (AWT), and aortic distensibility (AD). Purpose To determine the relationship of AC, AWT, and AD with the severity of CAD. Material and Methods A total of 104 patients who underwent both coronary CT angiography (CCTA) and invasive coronary angiography were enrolled. The severity of CAD was assessed by three methods: the segment involvement score (SIS), the segment stenosis score (SSS), and the modified Gensini score (mG). We quantified AC using the Agatston method on low-dose ungated chest CT (LDCT). We measured AWT at the thickest portion of the descending thoracic aorta on CCTA. AD was calculated as the difference between the maximum and minimum areas of the ascending aorta and the pulse pressure. The relationships between the severity of CAD and the three aortic factors were assessed. Results The AC and AWT of the thoracic aorta were significantly higher in the occlusive CAD (OCAD) group (1984.21 {+-} 2986.10 vs. 733.00 {+-} 1648.71, P = 0.01; 4.13 {+-} 1.48 vs. 3.40 {+-} 1.01, P = 0.22). Patients with OCAD had more than one epicardial coronary artery with >50% luminal stenosis. The AC (r = 0.453 with SIS; r = 0.454 with SSS; r = 0.427 with mG) and the AWT (r = 0.279 with SIS; r = 0.324 with SSS; r = 0.304 with mG) were significantly correlated with all three methods, and the AD was negatively correlated with the SIS (r = - 0.221, P < 0.05, respectively) in the unadjusted model. After adjustment for cardiovascular risk factors, only the correlations between AC and all three methods assessing CAD remained significant. Conclusion There are significant relationships between AC, AWT and AD and severity of CAD. In particular, AC measured on LDCT is the most consistent predictor of severity of CAD.

  6. The role of CT and MR in diagnosis of aortic dissection

    International Nuclear Information System (INIS)

    Yoon, Kwon Ha; Lim, Tae Hwan; Song, Koun Sik; Min, Kyung Seok; Song, Meong Gun

    1994-01-01

    The purpose of this study was to determine the role of CT and MR imagings in the diagnosis of aortic dissection and differentiation between the true and false lumen. We retrospectively studied forty patients with aortic dissection(AD) diagnosed by imagings or surgery. Of the forty patients, 19 were examined with only CT, 14 with CT and MR, and 7 with MR. Our points of view were(1) the classification of AD according to configuration of intimal flap by cross-sectional imaging, (2) differentiation between the true and false lumens, (3) the course of the false lumen, and (4) detectability of the origin of major branch vessels of the abdominal aorta. The classification by cross-sectional imaging were crescentic(65%), circumferential(15%), flat(12%), and irregular(8%) type, in which false negative diagnosis was made in 1 case of crescentic and circumferential type, respectively. In 2 case of flat type and 1 case of irregular type, the differentiation between the true and false lumen was impossible with CT. The course of the false lumen in descending thoracic aorta revealed counterclock wise rotation(66%), clockwise rotation(5%) or fixed(29%) appearance. MR imaging was superior to CT in the detection of the origin of major branch vessels of the abdominal aorta. The determination of the origin of major branches of abdominal aorta arising from the true and false lumen were impossible in 2 cases in which only CT was done. Diagnosis of crescentic and circumferential types of AD with narrow and thrombosed false lumen was problematic in both CT and MR with no difference of diagnostic accuracy between the two modalities. The differentiation between the true and false lumen was difficult in flat and irregular types with only CT. Therefore, when surgical treatment is considered as in type B aortic dissection, MR imaging is recommended in order to determine the origin of major branch vessels

  7. Coronary artery narrowing after aortic root reconstruction with resorcin-formalin glue.

    Science.gov (United States)

    Martinelli, L; Graffigna, A; Guarnerio, M; Bonmassari, R; Disertori, M

    2000-11-01

    Severe stenosis of right and left main coronary artery ostia developed after aortic root reconstruction with gelatin-resorcin-formol glue for correction of acute type A aortic dissection. Surgical treatment of this condition required grafting of the right and left anterior descending arteries with bilateral mammary arteries on the beating heart.

  8. Transport of 125I-albumin across normal and deendothelialized rabbit thoracic aorta in vivo

    International Nuclear Information System (INIS)

    Ramirez, C.A.; Colton, C.K.; Smith, K.A.; Stemerman, M.B.; Lees, R.S.

    1984-01-01

    Transmural concentration profiles of 125 I-albumin in vivo were measured across the normal and balloon catheter-deendothelialized rabbit descending thoracic aorta as a function of time following intravenous injection. A tracer was injected 5 or 60 minutes after deendothelialization, and the animals were sacrificed after circulation times of 10, 30 or 60 minutes. The aorta was immediately excised and frozen flat between glass slides. Samples were serially sectioned parallel to the intimal surface in a refrigerated microtome, washed with trichloroacetic acid (TCA), and counted. Relative tissue concentration profiles of TCA-precipitable radioactivity from the media of control animals showed entry from both luminal and adventitial sides, as previously found with conscious normal rabbits, but spatial gradients at both luminal and medial-adventitial borders were less steep. Relative concentration levels in ballooned animals were 10- to 40-fold higher than in controls, and the profiles were flatter. Uptake rates at equivalent circulation times were greater in experiments initiated 60 minutes, as compared with 5 minutes, after deendothelialization, suggesting that progressive medial edema may have occurred following balloon injury. These results show that the intact endothelium is the dominant mass transfer resistance for 125 I-albumin transport across the aortic wall. The data also suggest that the incomplete monolayer of platelets adherent to the subendothelium after balloon deendothelialization is not a substantial resistance to transport, as compared to that of the media, and that convection plays a more important role than diffusion for 125 I-albumin transport across the deendothelialized aortic wall

  9. [Modern aortic surgery in Marfan syndrome--2011].

    Science.gov (United States)

    Kallenbach, K; Schwill, S; Karck, M

    2011-09-01

    Marfan syndrome is a hereditary disease with a prevalence of 2-3 in 10,000 births, leading to a fibrillin connective tissue disorder with manifestations in the skeleton, eye, skin, dura mater and in particular the cardiovascular system. Since other syndromes demonstrate similar vascular manifestations, but therapy may differ significantly, diagnosis should be established using the revised Ghent nosology in combination with genotypic analysis in specialized Marfan centres. The formation of aortic root aneurysms with the subsequent risk of acute aortic dissection type A (AADA) or aortic rupture limits life expectancy in patients with Marfan syndrome. Therefore, prophylactic replacement of the aortic root needs to be performed before the catastrophic event of AADA can occur. The goal of surgery is the complete resection of pathological aortic tissue. This can be achieved with excellent results by using a (mechanically) valved conduit that replaces both the aortic valve and the aortic root (Bentall operation). However, the need for lifelong anticoagulation with Coumadin can be avoided using the aortic valve sparing reimplantation technique according to David. The long-term durability of the reconstructed valve is favourable, and further technical improvements may improve longevity. Although results of prospective randomised long-term studies comparing surgical techniques are lacking, the David operation has become the surgical method of choice for aortic root aneurysms, not only at the Heidelberg Marfan Centre. Replacement of the aneurysmal dilated aortic arch is performed under moderate hypothermic circulatory arrest combined with antegrade cerebral perfusion using a heart-lung machine, which we also use in thoracic or thoracoabdominal aneurysms. Close post-operative follow-up in a Marfan centre is pivotal for the early detection of pathological changes on the diseased aorta.

  10. Ruptured Aortic Aneurysm Presenting as a Stridor

    Directory of Open Access Journals (Sweden)

    Feng Lin

    2010-06-01

    Full Text Available Stridor is an abnormal, high-pitched, whining breathing sound caused by a blockage in the throat or larynx that is usually heard in children. We describe an unusual case of an 81-year-old man brought to our emergency department with sudden onset of dyspnea and shortness of breath. Stridor could be heard without a stethoscope. We found a huge mass over the left upper chest on chest radiography, suggesting an aortic aneurysm. We believed that these symptoms were caused by a huge thoracic aortic aneurysm with trachea/bronchi compression. Chest computed tomography confirmed the diagnosis.

  11. Stanford type A aortic dissection with closed false lumen: Analysis of prognostic factors at initial CT or MRI

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, Yohjiro; Sakamoto, Ichiro; Ogawa, Yohji; Sueyoshi, Eijun; Hayashi, Kuniaki; Takagi, Masatake [Nagasaki Univ. (Japan). School of Medicine; Narimatsu, Motoharu

    1997-08-01

    Nineteen patients with Stanford type A acute aortic dissection with closed false lumen were reviewed. In the follow-up examinations, ulcerlike projection (ULP) in the ascending aorta (AA) or aortic arch (AR) was identified in 8 of 19 patients. In 5 of these 8 patients, acute cardiac tamponade occurred and 3 of them died. In the other 11 patients, there was no mortality, and only one patient underwent elective surgery. The appearance of ULP in the AA/AR is considered an indication for urgent surgery because it is regarded as a precursor of lethal complications such as cardiac tamponade. The purpose of this study was to investigate predictors of the appearance of ULP in the AA/AR with early imagings (CT or MRI) before the appearance of ULP. The patients were divided into two groups: patients with ULP in the AA/AR (8 patients) and others (11 patients). Initial CT or MRI findings of the thoracic aorta were retrospectively statistically analyzed in each group. Three predictive factors were statistically significant for the appearance of ULP in the AA/AR (diameter of the AA{>=}5 cm, thickness of the false lumen of the AA{>=}1 cm, thickness of the false lumen of the AA{>=} that of the descending aorta). Close attention should be paid, if any of these 3 factors is observed at initial CT or MRI. (author)

  12. Stanford type A aortic dissection with closed false lumen: Analysis of prognostic factors at initial CT or MRI

    International Nuclear Information System (INIS)

    Matsuoka, Yohjiro; Sakamoto, Ichiro; Ogawa, Yohji; Sueyoshi, Eijun; Hayashi, Kuniaki; Takagi, Masatake; Narimatsu, Motoharu.

    1997-01-01

    Nineteen patients with Stanford type A acute aortic dissection with closed false lumen were reviewed. In the follow-up examinations, ulcerlike projection (ULP) in the ascending aorta (AA) or aortic arch (AR) was identified in 8 of 19 patients. In 5 of these 8 patients, acute cardiac tamponade occurred and 3 of them died. In the other 11 patients, there was no mortality, and only one patient underwent elective surgery. The appearance of ULP in the AA/AR is considered an indication for urgent surgery because it is regarded as a precursor of lethal complications such as cardiac tamponade. The purpose of this study was to investigate predictors of the appearance of ULP in the AA/AR with early imagings (CT or MRI) before the appearance of ULP. The patients were divided into two groups: patients with ULP in the AA/AR (8 patients) and others (11 patients). Initial CT or MRI findings of the thoracic aorta were retrospectively statistically analyzed in each group. Three predictive factors were statistically significant for the appearance of ULP in the AA/AR (diameter of the AA≥5 cm, thickness of the false lumen of the AA≥1 cm, thickness of the false lumen of the AA≥ that of the descending aorta). Close attention should be paid, if any of these 3 factors is observed at initial CT or MRI. (author)

  13. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology (Korea, Republic of); Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C. [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States); Kern, John A.; Cherry, Kenneth J. [University of Virginia Health System, Department of Surgery (United States); Matsumoto, Alan H., E-mail: ahm4d@virginia.edu [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States)

    2012-12-15

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 {+-} 5.6 mm; range 1.5-25.0 mm) and diameter (mean, 13.5 {+-} 9.7 mm; range 2.2-41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  14. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C.; Kern, John A.; Cherry, Kenneth J.; Matsumoto, Alan H.

    2012-01-01

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 ± 5.6 mm; range 1.5–25.0 mm) and diameter (mean, 13.5 ± 9.7 mm; range 2.2–41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  15. Digital subtraction angiography of the thoracic aorta

    International Nuclear Information System (INIS)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-01-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram

  16. Digital subtraction angiography of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-02-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram.

  17. Preoperative computer tomography evaluation in transcatheter aortic valve replacement (TAVI)

    International Nuclear Information System (INIS)

    Groudeva, V.; Stoynova, V.; Trendafilova, D.; Dzhorgova, Y.; Nachev, G.

    2014-01-01

    Transcatheter aortic valve replacement is rapidly emerging technique alternative to surgery in high risk patients. Imaging and especially computer tomography is important in preoperative assessment of the aortic ring and the prosthetic valve choice. The aim of this study is to share authors initial experience in CT assessment of the aortic ring prior to Transcatheter aortic valve replacement. 49 patients (mean age 76,55) underwent 320 rows MDCT (Acquilon One) prior TAVI. Protocol involved scanning from thoracic inlet to common femoral arteries. Aortic root size, aortic diameter at the level of coronary sinuses and the sinotubular junction and distance to coronary ostia were evaluated on a Vitrea work station. MDCT established maximal aortic ring diameter from 18 to 31 mm mean 25,04 mm while the lesser rate was from 16 to 21 mm. Accordingly positioned prostheses were in 34,75% No. 23, in 49% - No. 26 and in16,3% - No. 29. MDCT is crucial in aortic valve assessment prior to TAVI in experienced hands and multidisciplinary team. (authors) Key words: TRANSCATHETER AORTIC VALVE REPLACEMENT (TAVI). MDCT AORTIC VALVE ASSESSMENT

  18. Aortic Arch Aneurysms: Treatment with Extra anatomical Bypass and Endovascular Stent-Grafting

    International Nuclear Information System (INIS)

    Kato, Noriyuki; Shimono, Takatsugu; Hirano, Tadanori; Mizumoto, Toru; Ishida, Masaki; Fujii, Hideki; Yada, Isao; Takeda, Kan

    2002-01-01

    Endovascular repair of thoracic aortic aneurysms is emerging as an attractive alternative to surgical graft replacement. However,patients with aortic arch aneurysms are often excluded from the target of endovascular repair because of lack of suitable landing zones, especially at the proximal ones. In this paper we describe our method for treating patients with aortic arch aneurysms using a combination of extra anatomical bypass surgery and endovascular stent-grafting

  19. Aortic valve function after bicuspidization of the unicuspid aortic valve.

    Science.gov (United States)

    Aicher, Diana; Bewarder, Moritz; Kindermann, Michael; Abdul-Khalique, Hashim; Schäfers, Hans-Joachim

    2013-05-01

    Unicuspid aortic valve (UAV) anatomy leads to dysfunction of the valve in young individuals. We introduced a reconstructive technique of bicuspidizing the UAV. Initially we copied the typical asymmetry of a normal bicuspid aortic valve (BAV) (I), later we created a symmetric BAV (II). This study compared the hemodynamic function of the two designs of a bicuspidized UAV. Aortic valve function was studied at rest and during exercise in 28 patients after repair of UAV (group I, n = 8; group II, n = 20). There were no differences among the groups I and II with respect to gender, age, body size, or weight. All patients were in New York Heart Association class I. Six healthy adults served as control individuals. All patients were studied with transthoracic echocardiography between 4 and 65 months postoperatively. Systolic gradients were assessed by continuous wave Doppler while patients were at rest and exercising on a bicycle ergometer. Aortic regurgitation was grade I or less in all patients. Resting gradients were significantly elevated in group I compared with group II and control individuals (group I, peak 33.8 ± 7.8 mm Hg; mean 19.1 ± 5.4 mm Hg; group II, peak 15.8 ± 5.4, mean 8.2 ± 2.8 mm Hg; control individuals, peak 6.0 ± 1.6, mean 3.2 ± 0.8 mm Hg; p competence. A symmetric repair design leads to improved systolic aortic valve function at rest and during exercise. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Cisto tímico como diagnóstico diferencial de doença aguda da aorta torácica Thymic cyst as a differencial diagnosis of acute thoracic aortic disease

    Directory of Open Access Journals (Sweden)

    Marcos Gradim Tiveron

    2008-12-01

    Full Text Available Paciente encaminhada de outro serviço com história de dor torácica aguda de forte intensidade com diagnóstico de hematoma intramural na aorta ascendente para correção cirúrgica. Após investigação diagnóstica, identificou-se tumoração cística no mediastino anterior, que envolvia toda a aorta ascendente e que produzia restrição ao enchimento diastólico do ventrículo direito. A análise histológica do tumor ressecado revelou o diagnóstico de cisto tímico. Objetivo deste relato é descrever tumoração mediastinal de baixa prevalência, que pode produzir imagem radiológica com características de hematoma intramural e resultar em conduta terapêutica equivocada.Patient was referred to our Service with acute thoracic pain and diagnosis of intramural hematoma of the ascending aorta for surgical correction. The diagnostic investigation showed a cystic tumor involving the ascending aorta causing restriction of the right ventricular inflow. After resection, the histologic analysis disclosed the diagnosis of thymic cyst. The aim of this study is to describe a rare mediastinal tumor that may simulate a radiologic feature with characteristics of intramural hematoma and may result in a wrong therapeutic approach.

  1. Thoracic Ganglioneuromas Resulting in Nonimmune Hydrops Fetalis

    Directory of Open Access Journals (Sweden)

    Paul Singh

    2014-05-01

    Full Text Available Introduction - Most often, ganglioneuromas affect older pediatric and adult patients. They are typically slow growing tumors that remain clinically silent until they become large enough to cause symptoms by compression of adjacent structures. Case - We report a case of a 22-year-old Hispanic gravida 2 para 1 female patient who was found to have massive hydrops fetalis at 20 completed gestational weeks. Fetal echocardiography revealed a narrowed distal ductal arch and proximal descending aorta. Cesarean delivery was undertaken at 29 completed gestational weeks for refractory labor and nonreassuring fetal status. The neonate expired at 47 minutes of life despite aggressive resuscitation. At autopsy, multiple thoracic masses were found adjacent to a compressed proximal descending aorta. Histological and immunohistochemical analysis confirmed the diagnosis of a ganglioneuroma, a rare type of neural crest tumor. Discussion - A variety of intrathoracic masses have previously been reported to cause hydrops fetalis including teratomas, fibrosarcomas, and lymphangiomas. To our knowledge, this case is the first description of hydrops fetalis caused by ganglioneuromas. We propose that multiple thoracic ganglioneuromas led to biventricular distal outflow tract obstruction and hydrops fetalis.

  2. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  3. Thoracic myelopathy with alkaptonuria.

    Science.gov (United States)

    Akeda, Koji; Kasai, Yuichi; Kawakita, Eiji; Matsumura, Yoshihiro; Kono, Toshibumi; Murata, Tetsuya; Uchida, Atsumasa

    2008-01-15

    A case of thoracic myelopathy with alkaptonuria (ochronotic spondyloarthropathy) is presented. To present and review the first reported case of an alkaptonuric patient with concomitant thoracic myelopathy. Alkaptonuria, a rare hereditary metabolic disease, is characterized by accumulation of homogentistic acid, ochronosis, and destruction of connective tissue resulting in degenerative spondylosis and arthritis. Despite the high incidence of intervertebral disc diseases among patients with alkaptonuria, neurologic symptoms caused by spinal disease are rare. Thoracic myelopathy in a patient with alkaptonuria has not been previously reported. The clinical course, radiologic features, pathology, and treatment outcome of an alkaptonuria patient with thoracic myelopathy was documented. Myelopathy of the patient was caused by rupture of a thoracic intervertebral disc. The neurologic symptoms of the patient were markedly improved after surgery. We have reported for the first time, that an alkaptonuria patient showed thoracic myelopathy caused by rupture of a thoracic intervertebral disc. Decompression followed by the instrumented fusion of the thoracic spine was effective for improving the neurologic symptoms.

  4. Thoracic spine pain

    Directory of Open Access Journals (Sweden)

    Aleksey Ivanovich Isaikin

    2013-01-01

    Full Text Available Thoracic spine pain, or thoracalgia, is one of the common reasons for seeking for medical advice. The epidemiology and semiotics of pain in the thoracic spine unlike in those in the cervical and lumbar spine have not been inadequately studied. The causes of thoracic spine pain are varied: diseases of the cardiovascular, gastrointestinal, pulmonary, and renal systems, injuries to the musculoskeletal structures of the cervical and thoracic portions, which require a thorough differential diagnosis. Facet, costotransverse, and costovertebral joint injuries and myofascial syndrome are the most common causes of musculoskeletal (nonspecific pain in the thoracic spine. True radicular pain is rarely encountered. Traditionally, treatment for thoracalgia includes a combination of non-drug and drug therapies. The cyclooxygenase 2 inhibitor meloxicam (movalis may be the drug of choice in the treatment of musculoskeletal pain.

  5. Surgical treatment of infective endocarditis with aortic and tricuspid valve involvement using cryopreserved aortic and mitral valve allografts.

    Science.gov (United States)

    Ostrovsky, Yury; Spirydonau, Siarhei; Shchatsinka, Mikalai; Shket, Aliaksandr

    2015-05-01

    Surgical treatment of infective and prosthetic endocarditis using allografts gives good results. Aortic allograft implantation is a common technique, while tricuspid valve replacement with a mitral allograft is very rare. Multiple valve disease in case of infective endocarditis is a surgical challenge as such patients are usually in a grave condition and results of surgical treatment are often unsatisfactory. In this article we describe a clinical case of successful surgical treatment in a patient with active infective endocarditis of aortic and tricuspid valve, complicated by an aortic-right ventricular fistula. The aortic valve and ascending aorta were replaced with a cryopreserved aortic allograft; the tricuspid valve was replaced with a cryopreserved mitral allograft. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Magnetic resonance-thoracic ductography. Imaging aid for thoracic surgery and thoracic duct depiction based on embryological considerations

    International Nuclear Information System (INIS)

    Okuda, Itsuko; Udagawa, Harushi; Takahashi, Junji; Yamase, Hiromi; Kohno, Tadasu; Nakajima, Yasuo

    2009-01-01

    We describe the optimal protocol of magnetic resonance-thoracic ductography (MRTD) and provide examples of thoracic ducts (TD) and various anomalies. The anatomical pathway of the TD was analyzed based on embryological considerations. A total of 78 subjects, consisting of noncancer adults and patients with esophageal cancer and lung cancer, were enrolled. The MRTD protocol included a long echo time and was based on emphasizing signals from the liquid fraction and suppressing other signals, based on the principle that lymph flow through the TD appears hyperintense on T2-weighted images. The TD configuration was classified into nine types based on location [right and/or left side(s) of the descending aorta] and outflow [right and/or left venous angle(s)]. MRTD was conducted in 78 patients, and the three-dimensional reconstruction was considered to provide excellent view of the TD in 69 patients, segmentalization of TD in 4, and a poor view of the TD in 5. MRTD achieved a visualization rate of 94%. Most of the patients had a right-side TD that flowed into the left venous angle. Major configuration variations were noted in 14% of cases. Minor anomalies, such as divergence and meandering, were frequently seen. MRTD allows noninvasive evaluation of TD and can be used to identify TD configuration. Thus, this technique is considered to contribute positively to safer performance of thoracic surgery. (author)

  7. Endovascular Repair of Traumatic Rupture of the Thoracic Aorta: Single-Center Experience

    International Nuclear Information System (INIS)

    Saratzis, Nikolaos A.; Saratzis, Athanasios N.; Melas, Nikolaos; Ginis, Georgios; Lioupis, Athanasios; Lykopoulos, Dimitrios; Lazaridis, John; Dimitrios, Kiskinis

    2007-01-01

    Purpose. Traumatic rupture of the thoracic aorta secondary to blunt chest trauma is a life-threatening emergency and a common cause of death, usually following violent collisions. The objective of this retrospective report was to evaluate the efficacy of endovascular treatment of thoracic aortic disruptions with a single commercially available stent-graft. Methods. Nine men (mean age 29.5 years) were admitted to our institution between January 2003 and January 2006 due to blunt aortic trauma following violent motor vehicle collisions. Plain chest radiography, spiral computed tomography, aortography, and transesophageal echocardiography were used for diagnostic purposes in all cases. All patients were diagnosed with contained extramural thoracic aortic hematomas, secondary to aortic disruption. One patient was also diagnosed with a traumatic thoracic aortic dissection, secondary to blunt trauma. All subjects were poor surgical candidates, due to major injuries such as multiple bone fractures, abdominal hematomas, and pulmonary contusions. All repairs were performed using the EndoFit (LeMaitre Vascular) stent-graft. Results. Complete exclusion of the traumatic aortic disruption and pseudoaneurysm was achieved and verified at intraoperative arteriography and on CT scans, within 10 days of the repair in all patients. In 1 case the deployment of a second cuff was necessary due to a secondary endoleak. In 2 cases the left subclavian artery was occluded to achieve adequate graft fixation. No procedure-related deaths have occurred and no cardiac or peripheral vascular complications were observed within the 12 months (range 8-16 months) follow-up. Conclusions. This is the first time the EndoFit graft has been utilized in the treatment of thoracic aortic disruptions secondary to chest trauma. The repair of such pathologies is technically feasible and early follow-up results are promising

  8. Fatal dissection of the descending aorta after implantation of a stent in a 19-year-old female with Turner's syndrome.

    NARCIS (Netherlands)

    Fejzic, Z.; Oort, A.M. van

    2005-01-01

    We report a fatal dissection of the descending aorta as a complication after a two-staged implantation of a stent to relieve aortic coarctation in a young female with Turner's syndrome. Implantation of the stent, with dilation up to 70 percent, and half a year later re-dilation to 100 percent, was

  9. Descending necrotizing mediastinitis following dental extraction. Radiological features and surgical treatment considerations.

    Science.gov (United States)

    González-García, Raúl; Risco-Rojas, Roberto; Román-Romero, Leticia; Moreno-García, Carlos; López García, Cipriano

    2011-07-01

    Descending necrotizing mediastinitis (DNM) following dental extraction is an extremely serious infection with a high mortality rate. Oral infection may rapidly descend into the mediastinum across the retropharyngeal and retrovisceral spaces. Once established, mediastinitis is rapidly followed by sepsis and death. If DNM is suspected cervical and thoracic CT must be carried out urgently. After this, prompt control of the upper airway with tracheostomy, aggressive surgical debridement of the deep cervical spaces and mediastinum, and intravenous broad spectrum antibiotic therapy are mandatory. The present paper reports two new cases of DNM following dental extraction, and focuses on radiological features of abscess progression through the cervical spaces down into the mediastinum. 2010 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Diversity of Cortico-descending Projections

    DEFF Research Database (Denmark)

    Innocenti, Giorgio M; Caminiti, Roberto; Rouiller, Eric M

    2018-01-01

    The axonal composition of cortical projections originating in premotor, supplementary motor (SMA), primary motor (a4), somatosensory and parietal areas and descending towards the brain stem and spinal cord was characterized in the monkey with histological tract tracing, electron microscopy (EM) a...

  11. Computed tomography evaluation of traumatic rupture of the thoracic aorta: an outcome study

    International Nuclear Information System (INIS)

    Ellis, J.D.; Mayo, J.R.

    2007-01-01

    To assess the long-term outcome of blunt trauma patients with suspected thoracic aortic or great vessel injury that was evaluated with contrast-enhanced chest computed tomography (CT). We studied the outcome of 278 consecutive patients who received contrast enhanced CT for blunt chest trauma with computerized searches of the regional trauma database, hospital medical records, universal government medical coverage plan billing records, and regional vital statistics databases. Data retrieved included patient demographics, mechanism of injury, status of the aorta and proximal great vessels at contrast-enhanced CT, hospital discharge diagnoses, and outpatient procedural billings with specific attention to aortic or great vessel injury. Median follow-up was 615 days following the traumatic event. Six subjects demonstrated direct signs of aortic or proximal great vessel injury on contrast-enhanced chest CT, as follows: aortic pseudoaneurysm and intimal flap (n = 4), carotid artery dissection (n = 1), and aortic dissection (n 1). All were surgically treated, except the patient with aortic dissection, who was treated medically. In the other subjects, contrast-enhanced CT was negative (n = 230) or showed isolated mediastinal hematoma (n = 42). The computerized searches of the medical databases showed that none of these 272 subjects had procedures for, or died from, aortic or great vessel injury during the follow-up period. Computerized searches of medical databases found no evidence of missed thoracic aortic or proximal great vessel injury in blunt trauma patients who were evaluated with contrast-enhanced chest CT. (author)

  12. 2D MR angiography of the aortic aneurysm

    International Nuclear Information System (INIS)

    Amanuma, Makoto; Hasegawa, Makoto; Watabe, Tsuneya; Heshiki, Atsuko

    1992-01-01

    2D time-of-flight MR angiography was performed in 6 cases of thoracic aortic aneurysm. Oblique saturation pulses were used to suppress the signals of the pulmonary artery and SVC, providing excellent selective MR aortograms. Three dimensional extension of the aneurysm and its relation with cervical branches were easily assessed. It could be possible to replace invasive aortography by this technique. (author)

  13. A Computational Model of a Descending Mechanosensory Pathway Involved in Active Tactile Sensing.

    Directory of Open Access Journals (Sweden)

    Jan M Ache

    2015-07-01

    Full Text Available Many animals, including humans, rely on active tactile sensing to explore the environment and negotiate obstacles, especially in the dark. Here, we model a descending neural pathway that mediates short-latency proprioceptive information from a tactile sensor on the head to thoracic neural networks. We studied the nocturnal stick insect Carausius morosus, a model organism for the study of adaptive locomotion, including tactually mediated reaching movements. Like mammals, insects need to move their tactile sensors for probing the environment. Cues about sensor position and motion are therefore crucial for the spatial localization of tactile contacts and the coordination of fast, adaptive motor responses. Our model explains how proprioceptive information about motion and position of the antennae, the main tactile sensors in insects, can be encoded by a single type of mechanosensory afferents. Moreover, it explains how this information is integrated and mediated to thoracic neural networks by a diverse population of descending interneurons (DINs. First, we quantified responses of a DIN population to changes in antennal position, motion and direction of movement. Using principal component (PC analysis, we find that only two PCs account for a large fraction of the variance in the DIN response properties. We call the two-dimensional space spanned by these PCs 'coding-space' because it captures essential features of the entire DIN population. Second, we model the mechanoreceptive input elements of this descending pathway, a population of proprioceptive mechanosensory hairs monitoring deflection of the antennal joints. Finally, we propose a computational framework that can model the response properties of all important DIN types, using the hair field model as its only input. This DIN model is validated by comparison of tuning characteristics, and by mapping the modelled neurons into the two-dimensional coding-space of the real DIN population. This

  14. Re-interventions on the thoracic and thoracoabdominal aorta in patients with Marfan syndrome

    OpenAIRE

    Schoenhoff, Florian S.; Carrel, Thierry P.

    2017-01-01

    The advent of multi-gene panel genetic testing and the discovery of new syndromic and non-syndromic forms of connective tissue disorders have established thoracic aortic aneurysms as a genetically mediated disease. Surgical results in patients with Marfan syndrome (MFS) provide an important benchmark for this patient population. Prophylactic aortic root surgery prevents acute dissection and has contributed to the improved survival of MFS patients. In the majority of patients, re-interventions...

  15. Selective Aortic Arch and Root Replacement in Repair of Acute Type A Aortic Dissection.

    Science.gov (United States)

    Fleischman, Fernando; Elsayed, Ramsey S; Cohen, Robbin G; Tatum, James M; Kumar, S Ram; Kazerouni, Kayvan; Mack, Wendy J; Barr, Mark L; Cunningham, Mark J; Hackmann, Amy E; Baker, Craig J; Starnes, Vaughn A; Bowdish, Michael E

    2018-02-01

    Controversy exists regarding the optimal extent of repair for type A aortic dissection. Our approach is to replace the ascending aorta, and only replace the aortic root or arch when intimal tears are present in those areas. We examined intermediate outcomes with this approach to acute type A aortic dissection repair. Between March 2005 and October 2016, 195 patients underwent repair of acute type A aortic dissection. Repair was categorized by site of proximal and distal anastomosis and extent of repair. Mean follow-up was 31.0 ± 30.9 months. Kaplan-Meier analysis was used to assess survival. Multiple variable Cox proportional hazards modeling was utilized to identify factors associated with overall mortality. Overall survival was 85.1%, 83.9%, 79.1%, and 74.4% at 6, 12, 36, and 60 months, respectively. Eight patients required reintervention. The cumulative incidence of aortic reintervention at 1 year with death as a competing outcome was 3.95%. Multiple variable regression analysis identified factors such as age, preoperative renal failure, concomitant thoracic endograft, postoperative myocardial infarction and sepsis, and need for extracorporeal membrane oxygenation as predictive of overall mortality. Neither proximal or distal extent of repair, nor need for reintervention affected overall survival (proximal: hazard ratio 1.63, 95% confidence interval: 0.75 to 3.51, p = 0.22; distal: hazard ratio 1.12, 95% confidence interval: 0.43 to 2.97, p = 0.81; reintervention: hazard ratio 0.03, 95% confidence interval: 0.002 to 0.490, p < 0.01). A selective approach to root and arch repair in acute type A aortic dissection is safe. If aortic reintervention is needed, survival does not appear to be affected. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Arch reconstruction with autologous pulmonary artery patch in interrupted aortic arch.

    Science.gov (United States)

    Lee, Won-Young; Park, Jeong-Jun

    2014-04-01

    Various surgical techniques have been developed for the repair of an interrupted aortic arch. However, tension and Gothic arch formation at the anastomotic site have remained major problems for these techniques: Excessive tension causes arch stenosis and left main bronchus compression, and Gothic arch configuration is related to cardiovascular complications. To resolve these problems, we adopted a modified surgical technique of distal aortic arch augmentation using an autologous main pulmonary artery patch. The descending aorta was then anastomosed to the augmented aortic arch in an end-to-side manner. Here, we report two cases of interrupted aortic arch that were repaired using this technique.

  17. Correlation between local hemodynamics and lesion distribution in a novel aortic regurgitation murine model of atherosclerosis.

    Science.gov (United States)

    Hoi, Yiemeng; Zhou, Yu-Qing; Zhang, Xiaoli; Henkelman, R Mark; Steinman, David A

    2011-05-01

    Following surgical induction of aortic valve regurgitation (AR), extensive atherosclerotic plaque development along the descending thoracic and abdominal aorta of Ldlr⁻/⁻ mice has been reported, with distinct spatial distributions suggestive of a strong local hemodynamic influence. The objective of this study was to test, using image-based computational fluid dynamics (CFD), whether this is indeed the case. The lumen geometry was reconstructed from micro-CT scanning of a control Ldlr⁻/⁻ mouse, and CFD simulations were carried out for both AR and control flow conditions derived from Doppler ultrasound measurements and literature data. Maps of time-averaged wall shear stress magnitude (TAWSS), oscillatory shear index (OSI) and relative residence time (RRT) were compared against the spatial distributions of plaque stained with oil red O, previously acquired in a group of AR and control mice. Maps of OSI and RRT were found to be consistent with plaque distributions in the AR mice and the absence of plaque in the control mice. TAWSS was uniformly lower under control vs. AR flow conditions, suggesting that levels (> 100 dyn/cm²) exceeded those required to alone induce a pro-atherogenic response. Simulations of a straightened CFD model confirmed the importance of anatomical curvature for explaining the spatial distribution of lesions in the AR mice. In summary, oscillatory and retrograde flow induced in the AR mice, without concomitant low shear, may exacerbate or accelerate lesion formation, but the distinct anatomical curvature of the mouse aorta is responsible for the spatial distribution of lesions.

  18. Comparison of fractional flow reserve of composite Y-grafts with saphenous vein or right internal thoracic arteries.

    Science.gov (United States)

    Glineur, David; Boodhwani, Munir; Poncelet, Alain; De Kerchove, Laurent; Etienne, Pierre Yves; Noirhomme, Philippe; Deceuninck, Paul; Michel, Xavier; El Khoury, Gebrine; Hanet, Claude

    2010-09-01

    Composite Y-grafts, using the left internal thoracic artery as the inflow, allow a more efficient use of conduits without the need to touch a diseased ascending aorta. Among other conduits, the saphenous vein graft may be an alternative to the radial artery in elderly patients. We evaluated the hemodynamic characteristics of 17 composite Y-grafts made with the left internal thoracic artery anastomosed to the left anterior descending coronary artery in all cases and with either the free right internal thoracic artery (RITA group, n = 10) or a saphenous vein graft (SVG group, n = 7) implanted proximally to the left internal thoracic artery and distally to the circumflex territory 6 months after the operation. At baseline, the pressure gradient measured with a 0.014-inch pressure wire was minimal between the aorta and the internal thoracic artery stem (2 +/- 1 mm Hg), the internal thoracic artery and left anterior descending (4 +/- 2 mm Hg), the internal thoracic artery and left circumflex (3 +/- 1 mm Hg), and the saphenous vein graft and left circumflex (2 +/- 2 mm Hg). During hyperemia induced by adenosine, the pressure gradient increased significantly to 6 +/- 2 mm Hg in the internal thoracic artery stem, 9 +/- 4 mm Hg in the internal thoracic artery and left anterior descending artery, 9 +/- 3 mm Hg in the internal thoracic artery and left circumflex, and 7 +/- 4 mm Hg in the saphenous vein graft and left circumflex. Fractional flow reserve was 0.94 +/- 0.02 in internal thoracic artery stem, 0.90 +/- 0.04 mm Hg in the internal thoracic artery and left anterior descending, 0.91 +/- 0.03 mm Hg in the internal thoracic artery and left circumflex, and 0.92 +/- 0.06 mm Hg in the saphenous vein graft and left circumflex. No difference between the two types of composite Y-grafts was observed for pressure gradients or fractional flow reserve measured in internal thoracic artery stem or in distal branches. Composite Y-grafts with saphenous vein or right internal thoracic

  19. MRI evaluation of the aortic disease; Zastosowanie tomografii rezonansu magnetycznego w rozpoznawaniu chorob aorty

    Energy Technology Data Exchange (ETDEWEB)

    Kapuscinski, O; Polkowski, J [Zaklad Radiologii, Inst. Kardiologii, Warsaw-Anin (Poland); Zaleska, T [Oddzial Kardiologii, CSK, Warsaw-Miedzylesie (Poland); Walecki, J; Biesiadko, M [Zaklad Diagnostyki Obrazowej, CMKP and CSK, Warsaw-Miedzylesie (Poland)

    1994-12-31

    The goal of our study was to establish the value of MRI in diagnosing aortic disease. During 3 years period 46 patients were examined (12 women aged from 6 to 62 years and 34 men aged from 8 to 72 years). In 28 cases the thoracic aorta was examined, in 6 cases the abdominal aorta and in 12 - both the thoracic and the abdominal aorta. MR images were performed on MRT 50 A Toshiba unit 0.5 T. MR images demonstrated aortic aneurysm (caused by atherosclerosis or trauma), aortic dissections, aortic anomalies (i.e. in Turner syndrome) and non-specific aortitis and vasculitis. We regard MRI as preferable noninvasive imaging technique in diagnosing aortic disease. (author) 13 refs, 3 figs

  20. Aortic regurgitation after valve-sparing aortic root replacement: modes of failure.

    Science.gov (United States)

    Oka, Takanori; Okita, Yutaka; Matsumori, Masamichi; Okada, Kenji; Minami, Hitoshi; Munakata, Hiroshi; Inoue, Takeshi; Tanaka, Akiko; Sakamoto, Toshihito; Omura, Atsushi; Nomura, Takuo

    2011-11-01

    Despite the positive clinical results of valve-sparing aortic root replacement, little is known about the causes of reoperations and the modes of failure. From October 1999 to June 2010, 101 patients underwent valve-sparing aortic root replacement using the David reimplantation technique. The definition of aortic root repair failure included the following: (1) intraoperative conversion to the Bentall procedure; (2) reoperation performed because of aortic regurgitation; and (3) aortic regurgitation equal to or greater than a moderate degree at the follow-up. Sixteen patients were considered to have repair failure. Three patients required intraoperative conversion to valve replacement, 3 required reoperation within 3 months, and another 8 required reoperation during postoperative follow-up. At initial surgery 5 patients had moderate to severe aortic regurgitation, 6 patients had acute aortic dissections, 3 had Marfan syndrome, 2 had status post Ross operations, 3 had bicuspid aortic valves, and 1 had aortitis. Five patients had undergone cusp repair, including Arantius plication in 3 and plication at the commissure in 2. The causes of early failure in 6 patients included cusp perforation (3), cusp prolapse (3), and severe hemolysis (1). The causes of late failure in 10 patients included cusp prolapse (4), commissure dehiscence (3), torn cusp (2), and cusp retraction (1). Patients had valve replacements at a mean of 23 ± 20.9 months after reimplantation and survived. Causes of early failure after valve-sparing root replacement included technical failure, cusp lesions, and steep learning curve. Late failure was caused by aortic root wall degeneration due to gelatin-resorcin-formalin glue, cusp degeneration, or progression of cusp prolapse. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Resuscitative Endovascular Balloon Occlusion of the Aorta and Resuscitative Thoracotomy in Select Patients with Hemorrhagic Shock: Early Results from the American Association for the Surgery of Trauma's Aortic Occlusion in Resuscitation for Trauma and Acute Care Surgery Registry.

    Science.gov (United States)

    Brenner, Megan; Inaba, Kenji; Aiolfi, Alberto; DuBose, Joseph; Fabian, Timothy; Bee, Tiffany; Holcomb, John B; Moore, Laura; Skarupa, David; Scalea, Thomas M

    2018-05-01

    Aortic occlusion is a potentially valuable tool for early resuscitation in patients nearing extremis or in arrest from severe hemorrhage. The American Association for the Surgery of Trauma's Aortic Occlusion in Resuscitation for Trauma and Acute Care Surgery registry identified trauma patients without penetrating thoracic injury undergoing aortic occlusion at the level of the descending thoracic aorta (resuscitative thoracotomy [RT] or zone 1 resuscitative endovascular balloon occlusion of the aorta [REBOA]) in the emergency department (ED). Survival outcomes relative to the timing of CPR need and admission hemodynamic status were examined. Two hundred and eighty-five patients were included: 81.8% were males, with injury due to penetrating mechanisms in 41.4%; median age was 35.0 years (interquartile range 29 years) and median Injury Severity Score was 34.0 (interquartile range 18). Resuscitative thoracotomy was used in 71%, and zone 1 REBOA in 29%. Overall survival beyond the ED was 50% (RT 44%, REBOA 63%; p = 0.004) and survival to discharge was 5% (RT 2.5%, REBOA 9.6%; p = 0.023). Discharge Glasgow Coma Scale score was 15 in 85% of survivors. Prehospital CPR was required in 60% of patients with a survival beyond the ED of 37% and survival to discharge of 3% (all p > 0.05). Patients who did not require any CPR before had a survival beyond the ED of 70% (RT 48%, REBOA 93%; p American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Thoracic and abdominopelvic actinomycosis

    African Journals Online (AJOL)

    thoracic disease.1,2,4 The chronic progressive suppurative infection ... venous Penicillin G for 4 - 6 weeks being the treatment of ... pathology was demonstrated in the liver. (Figs 7a and b ). .... ulceration (may resemble Crohn's disease).3. 2.

  3. Society of Thoracic Surgeons

    Science.gov (United States)

    ... Apply for Membership Membership Directory Pay Your Dues Industry Mailing List License & eBlast Communications Programs Advertise on ... Hotel Discount Copyright © 2017 The Society of Thoracic Surgeons. ...

  4. Suicide awareness of japanese family descendants

    Directory of Open Access Journals (Sweden)

    Carla Tiemi Kawaziri Diogo

    2014-10-01

    Full Text Available This study aimed to comprehend the meaning of suicide for Japanese descendants. This was a qualitative study, based on Grounded Theory, using a structured interview with sixteen questions, digitally recorded. Subjects were ten descendants who were interviewed in 2011. The opinions of the interviewed showed factors of psychological, social and cultural origin involved in suicide, such as: heredity, religion, mental health, personality characteristics and interpersonal relationships, pleasure and pain at work, stigma and consequences of the act on the family. Family without case of suicide showed attitudes of prejudice and judgment, while those with case displayed feelings of pain in their reports. It was concluded that the Japanese rigid culture, personality, interpersonal communication and the way family and work have effects on their behavior are predisposing factors to suicide, as well as the identification of these factors contributes to a better performance of the nurse.

  5. Aortic elongation in aortic aneurysm and dissection: the Tübingen Aortic Pathoanatomy (TAIPAN) project.

    Science.gov (United States)

    Krüger, Tobias; Sandoval Boburg, Rodrigo; Lescan, Mario; Oikonomou, Alexandre; Schneider, Wilke; Vöhringer, Luise; Lausberg, Henning; Bamberg, Fabian; Blumenstock, Gunnar; Schlensak, Christian

    2018-01-24

    To study the lengths and diameters of aortic segments in healthy and diseased aortas and to assess the role of aortic elongation in Type A aortic dissection (TAD) prediction. Ectasia and aneurysm were defined by ascending aorta diameters of 45-54 mm and ≥55 mm, respectively. Computed tomography angiography studies of 256 healthy, 102 ectasia, 38 aneurysm, 17 pre-TAD and 166 TAD aortas were analysed using curved multiplanar reformats. The study groups were structurally equal. The diameter of the ascending aorta was 35 mm in the control group and was larger (P TAD (43 mm) and TAD (56 mm) groups. The length of the ascending aorta from the aortic annulus to the brachiocephalic trunk was 92 mm in the control group, 113 mm in the ectasia group, 120 mm in the aneurysm group and 111 mm and 118 mm in the pre-TAD and TAD groups (all P TAD group and 48% of the TAD group. The correlation between the diameter and the length of the ascending aorta was r = 0.752; therefore, both parameters must be examined separately. A score considering both parameters identified 23.5% of pre-TAD patients, significantly more than the diameter alone, and 31.4% of ectasia aortas were elongated. Patients with ectatic (45-54 mm diameter) and elongated (≥120 mm) ascending aortas represent a high-risk subpopulation for TAD. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Myocardial blood flow during induced aortic hypertension in dogs

    International Nuclear Information System (INIS)

    Thai, B.N.; Levesque, M.J.; Nerem, R.M.

    1986-01-01

    Myocardial blood flow was measured in anesthetized dogs during control conditions and under conditions where the aortic pressure was increased due to aortic constriction or during infusion. Blood flow was measured using the radioactive microsphere technique. Radioactive microspheres (15 m Ce-141, Sr-85, and Sc-46) were injected under control, aortic constriction and arterenol infusion in four dogs and under control conditions in two others. All microsphere injections were performed under stabilized conditions. It was found that coronary blood flow rose by 80% during aortic constriction and by 158% during arterenol infusion (P < 0.05). This increase in blood flow was not uniform throughout the heart, and higher increases were observed in the middle and apex regions of the left ventricle. Furthermore, under hypertension the increase in blood flow in LAD (left anterior descending) perfused territories was slightly higher than that in CFX (left circumflex) perfused territories

  7. Aortic Volumetry at Contrast-Enhanced Magnetic Resonance Angiography: Feasibility as a Sensitive Method for Monitoring Bicuspid Aortic Valve Aortopathy.

    Science.gov (United States)

    Trinh, Brian; Dubin, Iram; Rahman, Ozair; Ferreira Botelho, Marcos P; Naro, Nicholas; Carr, James C; Collins, Jeremy D; Barker, Alex J

    2017-04-01

    Bicuspid aortic valve patients can develop thoracic aortic aneurysms and therefore require serial imaging to monitor aortic growth. This study investigates the reliability of contrast-enhanced magnetic resonance angiography (CEMRA) volumetry compared with 2-dimensional diameter measurements to identify thoracic aortic aneurysm growth. A retrospective, institutional review board-approved, and Health Insurance Portability and Accountability Act-compliant study was conducted on 20 bicuspid aortic valve patients (45 ± 8.9 years, 20% women) who underwent serial CEMRA with a minimum imaging follow-up of 11 months. Magnetic resonance imaging was performed at 1.5 T with electrocardiogram-gated, time-resolved CEMRA. Independent observers measured the diameter at the sinuses of Valsalva (SOVs) and mid ascending aorta (MAA) as well as ascending aorta volume between the aortic valve annulus and innominate branch. Intraobserver/interobserver coefficient of variation (COV) and intraclass correlation coefficient (ICC) were computed to assess reliability. Growth rates were calculated and assessed by Student t test (P volumetry. Three-dimensional CEMRA volumetry exhibited a larger effect when examining percentage growth, a better ICC, and a marginally lower COV. Volumetry may be more sensitive to growth and possibly less affected by error than diameter measurements.

  8. A comparison of conventional surgery, transcatheter aortic valve replacement, and sutureless valves in "real-world" patients with aortic stenosis and intermediate- to high-risk profile.

    Science.gov (United States)

    Muneretto, Claudio; Alfieri, Ottavio; Cesana, Bruno Mario; Bisleri, Gianluigi; De Bonis, Michele; Di Bartolomeo, Roberto; Savini, Carlo; Folesani, Gianluca; Di Bacco, Lorenzo; Rambaldini, Manfredo; Maureira, Juan Pablo; Laborde, Francois; Tespili, Maurizio; Repossini, Alberto; Folliguet, Thierry

    2015-12-01

    We sought to investigate the clinical outcomes of patients with isolated severe aortic stenosis and an intermediate- to high-risk profile treated by means of conventional surgery (surgical aortic valve replacement), sutureless valve implantation, or transcatheter aortic valve replacement in a multicenter evaluation. Among 991 consecutive patients with isolated severe aortic stenosis and an intermediate- to high-risk profile (Society of Thoracic Surgeons score >4 and logistic European System for Cardiac Operative Risk Evaluation I >10), a propensity score analysis was performed on the basis of the therapeutic strategy: surgical aortic valve replacement (n = 204), sutureless valve implantation (n = 204), and transcatheter aortic valve replacement (n = 204). Primary end points were 30-day mortality and overall survival at 24-month follow-up; the secondary end point was survival free from a composite end point of major adverse cardiac events (defined as cardiac-related mortality, myocardial infarction, cerebrovascular accidents, and major hemorrhagic events) and periprosthetic regurgitation greater than 2. Thirty-day mortality was significantly higher in the transcatheter aortic valve replacement group (surgical aortic valve replacement = 3.4% vs sutureless = 5.8% vs transcatheter aortic valve replacement = 9.8%; P = .005). The incidence of postprocedural was 3.9% in asurgical aortic valve replacement vs 9.8% in sutureless vs 14.7% in transcatheter aortic valve replacement (Prisk factor for overall mortality hazard ratio (hazard ratio, 2.5; confidence interval, 1.1-4.2; P = .018). The use of transcatheter aortic valve replacement in patients with an intermediate- to high-risk profile was associated with a significantly higher incidence of perioperative complications and decreased survival at short- and mid-term when compared with conventional surgery and sutureless valve implantation. Copyright © 2015 The American Association for Thoracic Surgery. Published by

  9. New predictor of aortic enlargement in uncomplicated type B aortic dissection based on elliptic Fourier analysis.

    Science.gov (United States)

    Sato, Hiroshi; Ito, Toshiro; Kuroda, Yosuke; Uchiyama, Hiroki; Watanabe, Toshitaka; Yasuda, Naomi; Nakazawa, Junji; Harada, Ryo; Kawaharada, Nobuyoshi

    2017-12-01

    This study aimed to re-examine the conventional predictive factors for dissected aortic enlargement, such as the aortic and false lumen diameter and to consider whether the morphological elements of the dissected aorta could be predictors by quantifying the 'shape' of the true lumen based on elliptic Fourier analysis. A total of 80 patients with uncomplicated type B aortic dissection were included. The patients were divided into 'Enlargement group' and 'No Change group.' Between the 2 groups, the mean systolic blood pressure during follow-up, aortic and false lumen maximum diameters, and analysed morphological data were compared using each statistical method. The maximum aortic and false lumen diameters were significantly larger in the Enlargement group than in the No Change group (39.3 vs 35.9 mm; P = 0.0058) (23.5 vs 18.2 mm; P = 0.000095). The principal component 1, which is the data calculated by elliptic Fourier analysis, was significantly lower in the Enlargement group than in the No Change group (0.020 vs - 0.072; P = 0.000049). The mean systolic blood pressure ≥130 mmHg, aortic diameter, false lumen diameter and principal component 1 were included in the Cox proportional hazard model as covariates to determine the significant predictive variable. Principal component 1 demonstrated the only significance with aortic enlargement on multivariate analysis (odds ratio = 0.32; P = 0.048). The analysed and calculated morphological data of the shape of the true lumen can be more effective predictive factors of aortic enlargement of type B dissection than the conventional factors. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. Imaging of thoracic trauma

    International Nuclear Information System (INIS)

    Uffmann, M.; Herold, C.J.; Fuchs, M.

    1998-01-01

    Blunt trauma to the chest results from transfer of kinetic energy to the human body. It may cause a wide range of mostly life-threatening injuries, including fractures of the thoracic skeleton, disintegration of the pleural space, contusion or laceration of pulmonary parenchyma and damage to the mediastinal structures. For a systematic approach it may be helpful to follow an organ-based evaluation of thoracic trauma. However, it should be borne in mind that subtle injuries may be associated with serious complications. Trauma to the chest may affect different anatomic compartments at the same time, requiring and extending diagnostic approach. Conventional radiography plays a major role in diagnosting thoracic trauma, complemented by ultrasound examination of the pleura and abdomen. It is well documented that CT scanning represents a major technological improvement for assessment of thoracic trauma. With the advent of fast helical CT scanning this method becomes more applicable for severly traumatized patients and potentially replaces other time-consuming procedures. State-of-the-art imaging of both projection and cross-sectional techniques provides useful information for immediate and appropriate treatment mandatory in patients with thoracic trauma. (orig.) [de

  11. Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices.

    Science.gov (United States)

    McKellar, Stephen H; Deo, Salil; Daly, Richard C; Durham, Lucian A; Joyce, Lyle D; Stulak, John M; Park, Soon J

    2014-01-01

    A competent aortic valve is essential to providing effective left ventricular assist device support. We have adopted a practice of central aortic valve closure by placing a simple coaptation stitch at left ventricular assist device implantation in patients with significant aortic insufficiency. We conducted a follow-up study to evaluate the efficacy and durability of this procedure. The study included patients who had undergone continuous flow left ventricular assist device implantation. The patients were divided into 2 groups, those who did not require any aortic procedure because the valve was competent and those who underwent central aortic valve closure for mild or greater aortic regurgitation. The clinical endpoints were mortality, progression or recurrence of aortic insufficiency, and reoperation for aortic valve pathologic features. Aortic insufficiency was measured qualitatively from mild to severe on a scale of 0 to 5. A total of 123 patients received continuous flow left ventricular assist devices from February 2007 to August 2011. Of those, 18 (15%) underwent central aortic valve closure at left ventricular assist device implantation because of significant aortic insufficiency (1.8 ± 1.4) and 105 who did not (competent aortic valve, 0.15 ± 0.43; P assist device-supported patients, with follow-up extending into 2 years. Although aortic insufficiency progressed over time in those with minimal native valve regurgitation initially, no such progression was noted in those with central aortic valve closure. Additional investigation is needed to evaluate whether prophylactic central aortic valve closure should be performed at left ventricular assist device implantation to avoid problematic aortic regurgitation developing over time, in particular in patients undergoing left ventricular assist device implantation for life-long (destination therapy) support. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights

  12. Right circumflex retro-oesophageal aortic arch with coarctation of a high-positioned right arch

    International Nuclear Information System (INIS)

    Ahn, Kyung-Sik; Yong, Hwan Seok; Woo, Ok Hee; Kang, Eun-Young; Lee, Joo-Won

    2007-01-01

    We present a rare case of right circumflex retro-oesophageal aortic arch with coarctation of a high-positioned right arch. A 7-month-old boy presented with a cardiac murmur. Cardiac situs was normal and there was no evidence of an intracardiac shunt or patent ductus arteriosus. MR aortography revealed a right aortic arch that was high-positioned, tortuous and narrowed. This right aortic arch crossed the midline behind the oesophagus and continued as a left-sided descending aorta. The left common carotid and subclavian arteries arose from a large branching vascular structure that derived from the top of the left-sided descending aorta. The right common carotid artery arose from the ascending aorta. The proximal portion of the right common carotid artery showed very severe stenosis and poststenotic dilatation. The right subclavian artery originated distal to the narrowed and tortuous segment of the aortic arch. (orig.)

  13. Cardiogenic shock due to coronary artery disease associated with interrupted aortic arch

    Directory of Open Access Journals (Sweden)

    Luís Alberto Oliveira Dallan

    2013-06-01

    Full Text Available Acute pulmonary edema is a serious event. Its occurrence in association with interrupted aortic arch and coronary heart disease is rare. Recently, an old patient developed cardiogenic shock and acute pulmonary edema due to acute coronary insufficiency, associated with interrupted aortic arch. The coronary angiography revealed occlusion of the right coronary artery and 95% obstruction in the left main coronary artery, associated with interruption of the descending aorta. Coronary artery bypass graft was performed, without extracorporeal circulation, to the anterior descending coronary artery. We discuss the initial management, given the seriousness of the case.

  14. Single Coronary Artery with Aortic Regurgitation

    International Nuclear Information System (INIS)

    Katsetos, Manny C.; Toce, Dale T.

    2003-01-01

    An isolated single coronary artery can be associated with normal life expectancy; however, patients are at an increased risk of sudden death. A case is reported of a 54-year-old man with several months of chest pressure with activity. On exercise Sestamibi stress testing, the patient developed a hypotensive response with no symptoms and minimal electrocardiographic changes. Nuclear scanning demonstrated reversible septal and lateral perfusion defects consistent with severe ischemia. Coronary angiography revealed a single coronary artery with the right coronary artery arising from the left main. There were high-grade stenotic lesions in the left anterior descending and circumflex arteries with only moderate atherosclerotic disease in the right coronary artery. An aortogram showed 2-3+ aortic regurgitation, with an ejection fraction of 45% on ventriculography. The patient underwent four-vessel revascularization and aortic valve replacement and did well postoperatively

  15. Aortic Annular Enlargement during Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Selman Dumani

    2016-09-01

    Full Text Available In the surgery of aortic valve replacement is always attempted, as much as possible, to implant the larger prosthesis with the mains goals to enhance the potential benefits, to minimise transvalvular gradient, decrease left ventricular size and avoid the phenomenon of patient-prosthesis mismatch. Implantation of an ideal prosthesis often it is not possible, due to a small aortic annulus. A variety of aortic annulus enlargement techniques is reported to avoid patient-prosthesis mismatch. We present the case that has submitted four three times open heart surgery. We used Manouguian technique to enlarge aortic anulus with excellent results during the fourth time of surgery.

  16. New paradigms in the management of acute type B aortic dissection.

    Science.gov (United States)

    Parisi, Rosario; Secco, Gioel Gabrio; Fattori, Rossella

    2015-11-01

    Type B aortic dissection is a relatively uncommon and multifaceted disease, whose management is ongoing debated. Its wide range of clinical presentations and anatomical features hamper the early identification and medical management. In the past few years, the introduction of endovascular techniques opened new paradigms in comprehension and management of aortic diseases. Aim of this review is to discuss contemporary therapeutic approaches of acute type B aortic dissections highlighting the growing role of thoracic endovascular aortic repair (TEVAR) in focusing its complex physiopathology. Prompt medical therapy followed by endovascular repair should be considered as the gold standard in complicated acute type B aortic dissection. Moreover, recent findings also suggest a potential benefit in case of uncomplicated cases. Management of acute type B aortic dissection is progressively shifting into endovascular approach. However, further studies are warranted to define the optimal treatment strategy in each subset of patients and anatomical features.

  17. Aortic valve surgery - open

    Science.gov (United States)

    ... gov/ency/article/007408.htm Aortic valve surgery - open To use the sharing features on this page, ... separates the heart and aorta. The aortic valve opens so blood can flow out. It then closes ...

  18. Abdominal Aortic Aneurysm (AAA)

    Science.gov (United States)

    ... Professions Site Index A-Z Abdominal Aortic Aneurysm (AAA) Abdominal aortic aneurysm (AAA) occurs when atherosclerosis or plaque buildup causes the ... weak and bulge outward like a balloon. An AAA develops slowly over time and has few noticeable ...

  19. Aortography following subdiaphragmal aortic biopsy

    International Nuclear Information System (INIS)

    Schimmler, J.

    1982-01-01

    A juxtaposition of the subdiaphragmal and infrarenal translumbar aortic biopsy sites showed decisive advantages in favour of the higher site: a more stable position because of better anatomic fixation and rarer incidence of vascular alterations, a wider vascular lumen. Disadvantages lie in the fact that the large visceral arteries (especially Tr. coeliacus) branch off nearly and in the close anatomic relationship to large abdominal organs and the thoracal region. Evaluation of the radiographical image of the vascular tree after subdiaphragmal aortic biopsy showed an average 82% of the vessels to the area of the Knees to be assessable (renal arteries approximately 93%, popliteal arteries approximately 70%). Beyong, the method proved unsatisfactory: 52% of the vessels could not, or not safety, be evaluated. A relatively broad spectrum of indications by comparison with transfemoral catheter aortography had no influence on the rate of complications with reference to either method. A comparison of the topographic conditions shows the need for even more scrupulons observation of the technique in subdiaphragmal biopsy than in the infrarenal one. To sum up the results obtained, subdiaphregmal translumbar aortography is to be preferred to the infrarenal one where transfemoral catheter aortography is contra-indicated, within the limits mentioned. (orig.) [de

  20. Aortic root surgery in Marfan syndrome.

    Science.gov (United States)

    Sheick-Yousif, Basheer; Sheinfield, Ami; Tager, Salis; Ghosh, Probal; Priesman, Sergey; Smolinsky, Aram K; Raanani, Ehud

    2008-03-01

    As the shortcomings of the Bentall operation and its variants in the Marfan syndrome have become apparent, the recent cusp-sparing techniques (remodeling or reimplantation) bear promise of better mid-term and long-term outcomes. To examine the results of aortic root surgery in patients with Marfan syndrome. During the period March 1994 to September 2007, 220 patients underwent aortic valve-sparing surgery; 20 were Marfan patients (group 1) who were compared with another 20 Marfan patients undergoing composite aortic root replacement (group 2). Fourteen patients had aortic dissection and 26 had thoracic aortic aneurysm. There were 31 males and 9 females with a mean age of 37.9 +/- 13.8 years. In group 1, reimplantation was used in 13 patients, remodeling in 4, and aortic valve repair with sinotubular junction replacement in 3. In group 2, a mechanical valve conduit was used. Mean logistic Euroscore was 12.27 +/- 14.6% for the whole group, five of whom were emergent cases Group 2 had more previous cardiac procedures compared to group 1 (9 vs. 2, P = 0.03) and shorter cross-clamp time (122 +/- 27.1 vs. 153.9 +/- 23.7 minutes, P = 0.0004). Overall mortality was 10%. Early mortality was 10% in group 2 and 5% in group 1 (NS). Mean follow-up time was 25 months for group 2 and 53 months for group 1. Three patients were reoperated; all had undergone the remodeling. Five year freedom from reoperation and death was 86% and 90% in group 2 and 70% and 95% in group 1 (P = 0.6, P = 0.6), respectively. Late survival of patients with Marfan syndrome was similar in both groups. Root reconstruction tends towards a higher incidence of late reoperations if the remodeling technique is used. We now prefer to use the reimplantation technique.

  1. Consumption coagulopathy in acute aortic dissection: principles of management.

    Science.gov (United States)

    Liu, Yuyong; Han, Lu; Li, Jiachen; Gong, Ming; Zhang, Hongjia; Guan, Xinliang

    2017-06-12

    The effect of acute aortic dissection itself on coagulopathy or surgery-related coagulopathy has never been specifically studied. The aim of the present study was to perioperatively describe consumption coagulopathy in patients with acute aortic dissection. Sixty-six patients with acute type A aortic dissection were enrolled in this study from January 2015 to September 2016. Thirty-six patients with thoracic aortic aneurysms were used as a control group during the same period. Consumption coagulopathy was evaluated using standard laboratory tests, enzyme-linked immunosorbent assay and thromboelastograghy at five perioperative time-points. A significant reduction in clotting factors and fibrinogen was observed at the onset of acute aortic dissection. Enzyme-linked immunosorbent assay and thromboelastograghy also revealed a persistent systemic activation of the coagulation system and the consumption of clotting factors. In contrast, although platelet counts were consistently low, we did not find that platelet function was more impaired in the acute aortic dissection group than the control group. After surgery, clotting factors and fibrinogen were more impaired than platelet function. Thus, we proposed that hemostatic therapy should focus on the rapid and sufficient supplementation of clotting factors and fibrinogen to improve consumption coagulopathy in patients with acute aortic dissection.

  2. Comparing American, European and Asian practice guidelines for aortic diseases.

    Science.gov (United States)

    Rozado, Jose; Martin, Maria; Pascual, Isaac; Hernandez-Vaquero, Daniel; Moris, Cesar

    2017-05-01

    The aortic disease comprises a group of different pathologies of high prevalence, seriousness and ever changing by the medical and surgical investigations. Therefore cardiovascular scientific societies in USA, Europe and Asia have created Task Force on practice guidelines (PG) to develop, update and revise PG for aortic diseases. These documents issue recommendations on the diagnosis and management of different aortic diseases. The three societies agree on the recommendations about diagnostic tests and on the value of computed tomography and magnetic resonance as the main tools for the diagnosis and follow-up of aortic disease. Concerning to acute aortic syndromes (AAS), American and European GPs recognize intramural hematoma (IMH) as a type of AAS with surgery indication; however Asian guidelines consider IMH a pathological process different from AAS and indicate medical treatment. In thoracic aortic aneurysms (TAA), all express the need for an adequate control of cardiovascular risk factors, emphasizing strict control of blood pressure, smoking cessation and recommend the use of beta-blockers and statins. The threshold for asymptomatic repair is 5.5 cm in European and American and 6 cm for Asian PG, with lower thresholds in Marfan and bicuspid aortic valve (BAV). As regards the abdominal aortic aneurysms (AAA), the PGs recognize the adequate control of cardiovascular risk factors, but there are differences in class of recommendation on statins, angiotensin-converting enzyme inhibitors or beta-blockers to prevent progression of AAA. For intervention, the threshold diameter in asymptomatic is 5.5 cm but can be reduced to 5 cm in women as recommended by Asian PG. Moreover the specific diseases such as Marfan, BAV, pregnancy or atherosclerosis aortic present specific recommendations with small differences between PGs. In conclusion, PGs are interesting and appropriate documents at present. They issue recommendations based on evidence that help the clinician and

  3. Spontaneous aortic dissecting hematoma in two dogs.

    Science.gov (United States)

    Boulineau, Theresa Marie; Andrews-Jones, Lydia; Van Alstine, William

    2005-09-01

    This report describes 2 cases of spontaneous aortic dissecting hematoma in young Border Collie and Border Collie crossbred dogs. Histology was performed in one of the cases involving an unusual splitting of the elastin present within the wall of the aorta, consistent with elastin dysplasia as described in Marfan syndrome in humans. The first case involved a young purebred Border Collie that died suddenly and the second case involved a Border Collie crossbred dog that died after a 1-month history of seizures. Gross lesions included pericardial tamponade with dissection of the ascending aorta in the former case and thoracic cavity hemorrhage, mediastinal hematoma, and aortic dissection in the latter. Histologic lesions in the case of the Border Collie crossbred dog included a dissecting hematoma of the ascending aorta with elastin dysplasia and right axillary arterial intimal proliferation.

  4. RADIOGRAPHIC THORACIC ANATOMY OF THE RED PANDA (AILURUS FULGENS).

    Science.gov (United States)

    Makungu, Modesta; du Plessis, Wencke M; Barrows, Michelle; Groenewald, Hermanus B; Koeppel, Katja N

    2016-09-01

    The red panda ( Ailurus fulgens ) is classified as an endangered species by the International Union for Conservation of Nature and Natural Resources. The natural distribution of the red panda is in the Himalayas and southern China. Thoracic diseases such as dirofilariasis, hypertrophic cardiomyopathy, tracheal obstruction, lung worm infestation, and pneumonia have been reported in the red panda. The aim of this study was to describe the normal radiographic thoracic anatomy of captive red pandas as a species-specific reference for routine health examinations and clinical cases. Right lateral (RL) and dorsoventral (DV) inspiratory phase views of the thorax were obtained in 11 adult captive red pandas. Measurements were made and ratios calculated to establish reference ranges for the mean vertebral heart score on the RL (8.34 ± 0.25) and DV (8.78 ± 0.34) views and the mean ratios of the caudal vena cava diameter to the vertebral body length above tracheal bifurcation (0.67 ± 0.05) and tracheal diameter to the width of the third rib (2.75 ± 0.24). The majority of animals (10/11) had 14 thoracic vertebrae, except for one animal that had 15 thoracic vertebrae. Rudimentary clavicles were seen in 3/11 animals. The ovoid, oblique cardiac silhouette was more horizontally positioned and elongated in older animals. A redundant aortic arch was seen in the oldest animal. The trachea was seen with mineralized cartilage rings in all animals. The carina was clearly seen in the majority of animals (10/11). Variations exist in the normal radiographic thoracic anatomy of different species. Knowledge of the normal radiographic thoracic anatomy of the red panda should prove useful for routine health examinations and in the diagnosis of thoracic diseases.

  5. Thrombosed false channel in acute aortic dissections

    International Nuclear Information System (INIS)

    Alerci, M.; Dore, R.; Kluzer, A.; Digiulio, G.; D'Andrea, F.; De Agostini, A.

    1987-01-01

    Three cases are reported of acute dissection with complete thrombosis of the false channel, which is a very uncommonevent in DeBakey's I and II type aortic dissections. The 3 patients entered hospital because of severe thoracic pain without any ECG sign of myocardial infarction. Emergency CT showed evidence of pericardial effusion suggesting hemopericardium, enlargement of the ascending aorta and a peripheral semilunar filling defect which caused a slight deformation of the true channel. On precontrast scans, only one case showed inward displacement of peripheral calcifications and high-density aortic wall. No tipical signs of aortic dissection were reported, expect in the first patient - where a double contrast filled lumen, separated by an intimal flap was seen. CT findings are individually discussed. It is emphasized that in all patients more than one CT sign was present at a time. The correct evaluation of these signs together with the clinacal data could lead to the right diagnosis of aortic dissection in spite of the lack of a f???

  6. Management of Recurrent Delayed Neurologic Deficit After Thoracoabdominal Aortic Operation.

    Science.gov (United States)

    Boutrous, Mina L; Afifi, Rana O; Safi, Hazim J; Estrera, Anthony L

    2016-01-01

    Delayed neurologic deficit (DND) is a devastating adverse event after thoracoabdominal aortic aneurysm repair. Multiple adjuncts have been devised to counteract the development of DND, most notably cerebrospinal fluid (CSF) drainage. We report a case of a 63-year-old woman in whom DND developed four times during the first 10 days after her thoracoabdominal aortic operation. This necessitated lumbar drain "weaning" to allow for a slowly rising CSF pressure and preservation of lower extremity motor function. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Total Percutaneous Aortic Repair: Midterm Outcomes

    International Nuclear Information System (INIS)

    Bent, Clare L.; Fotiadis, Nikolas; Renfrew, Ian; Walsh, Michael; Brohi, Karim; Kyriakides, Constantinos; Matson, Matthew

    2009-01-01

    The purpose of this study was to examine the immediate and midterm outcomes of percutaneous endovascular repair of thoracic and abdominal aortic pathology. Between December 2003 and June 2005, 21 patients (mean age: 60.4 ± 17.1 years; 15 males, 6 females) underwent endovascular stent-graft insertion for thoracic (n = 13) or abdominal aortic (n = 8) pathology. Preprocedural computed tomographic angiography (CTA) was performed to assess the suitability of aorto-iliac and common femoral artery (CFA) anatomy, including the degree of CFA calcification, for total percutaneous aortic stent-graft repair. Percutaneous access was used for the introduction of 18- to 26-Fr delivery devices. A 'preclose' closure technique using two Perclose suture devices (Perclose A-T; Abbott Vascular) was used in all cases. Data were prospectively collected. Each CFA puncture site was assessed via clinical examination and CTA at 1, 6, and 12 months, followed by annual review thereafter. Minimum follow-up was 36 months. Outcome measures evaluated were rates of technical success, conversion to open surgical repair, complications, and late incidence of arterial stenosis at the site of Perclose suture deployment. A total of 58 Perclose devices were used to close 29 femoral arteriotomies. Outer diameters of stent-graft delivery devices used were 18 Fr (n = 5), 20 Fr (n = 3), 22 Fr (n = 4), 24 Fr (n = 15), and 26 Fr (n = 2). Percutaneous closure was successful in 96.6% (28/29) of arteriotomies. Conversion to surgical repair was required at one access site (3.4%). Mean follow-up was 50 ± 8 months. No late complications were observed. By CT criteria, no patient developed a >50% reduction in CFA caliber at the site of Perclose deployment during the study period. In conclusion, percutaneous aortic stent-graft insertion can be safely performed, with a low risk of both immediate and midterm access-related complications.

  8. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  9. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  10. Segmental Aortic Stiffness in Children and Young Adults With Connective Tissue Disorders: Relationships With Age, Aortic Size, Rate of Dilation, and Surgical Root Replacement.

    Science.gov (United States)

    Prakash, Ashwin; Adlakha, Himanshu; Rabideau, Nicole; Hass, Cara J; Morris, Shaine A; Geva, Tal; Gauvreau, Kimberlee; Singh, Michael N; Lacro, Ronald V

    2015-08-18

    Aortic diameter is an imperfect predictor of aortic complications in connective tissue disorders (CTDs). Novel indicators of vascular phenotype severity such as aortic stiffness and vertebral tortuosity index have been proposed. We assessed the relation between aortic stiffness by cardiac MRI, surgical root replacement, and rates of aortic root dilation in children and young adults with CTDs. Retrospective analysis of cardiac MRI data on children and young adults with a CTD was performed to derive aortic stiffness measures (strain, distensibility, and β-stiffness index) at the aortic root, ascending aorta, and descending aorta. Vertebral tortuosity index was calculated as previously described. Rate of aortic root dilation before cardiac MRI was calculated as change in echocardiographic aortic root diameter z score per year. In 83 CTD patients (median age, 24 years; range, 1-55; 17% age; 60% male), ascending aorta distensibility was reduced in comparison with published normative values: median z score, -1.93 (range, -8.7 to 1.3; Pyoung adults with CTDs. © 2015 American Heart Association, Inc.

  11. Invasive aspergillosis in the aortic arch with infectious Aspergillus lesions in pulmonary bullae

    Directory of Open Access Journals (Sweden)

    Isao Watanabe

    2015-03-01

    Full Text Available A patient with pulmonary bullae died of massive hemoptysis. At autopsy a hole was observed in the aortic wall. A microscopic examination indicated small Aspergillus lesions in pulmonary bullae and extensive necrotic lesions with Aspergillus hyphae in the media of the thoracic aorta. These findings led to a diagnosis of invasive aspergillosis in the aortic arch. This is a rare case in which Aspergillus invaded the aorta in a patient without hematologic neoplasms or neutropenia.

  12. Trans-apical aortic valve implantation in a patient with stentless valve degeneration.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; MacCarthy, Philip; Monaghan, Mark; Wendler, Olaf

    2011-06-01

    Trans-apical valve-in-valve trans-catheter aortic valve implantation (TAVI) has successfully been performed in selected, high-risk patients, who suffered prosthetic degeneration after aortic valve replacement using stented xenografts. We report the case of a 79-year-old male patient who underwent one of the first successful TAVIs in a failing stentless bioprosthesis. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  13. A reappraisal of pediatric thoracic surface anatomy.

    Science.gov (United States)

    Fischer, Nicholas J; Morreau, Jonty; Sugunesegran, Ramanen; Taghavi, Kiarash; Mirjalili, S Ali

    2017-09-01

    Accurate knowledge of surface anatomy is fundamental to safe clinical practice. A paucity of evidence in the literature regarding thoracic surface anatomy in children was identified. The associations between surface landmarks and internal structures were meticulously analyzed by reviewing high quality computed tomography (CT) images of 77 children aged from four days to 12 years. The results confirmed that the sternal angle is an accurate surface landmark for the azygos-superior vena cava junction in a plane through to the level of upper T4 from birth to age four, and to lower T4 in older children. The concavity of the aortic arch was slightly below this plane and the tracheal and pulmonary artery bifurcations were even lower. The cardiac apex was typically at the 5 th intercostal space (ICS) from birth to age four, at the 4 th ICS and 5 th rib in 4-12 year olds, and close to the midclavicular line at all ages. The lower border of the diaphragm was at the level of the 6 th or 7 th rib at the midclavicular line, the 7 th ICS and 8 th rib at the midaxillary line, and the 11 th thoracic vertebra posteriorly. The domes of the diaphragm were generally flatter and lower in children, typically only one rib level higher than its anterior level at the midclavicular line. Diaphragm apertures were most commonly around the level of T9, T10, and T11 for the IVC, esophagus and aorta, respectively. This is the first study to provide an evidence-base for thoracic surface anatomy in children. Clin. Anat. 30:788-794, 2017. © 2017Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  14. Endovascular management of an acquired aortobronchial fistula following aortic bypass for coarctation.

    LENUS (Irish Health Repository)

    O'Sullivan, Katie E

    2013-09-20

    Aortobronchial fistula (ABF) in the setting of aortic coarctation repair is very rare but uniformly fatal if untreated. Endovascular stenting of the descending aorta is now the first-choice approach for ABF presenting with haemoptysis and offers a less-invasive technique with improved outcomes, compared with open repair. We report a case of late ABF occurring following bypass for aortic coarctation. Management focused on two key manoeuvres: use of a covered endovascular stent to occlude the aortic bypass thus controlling the fistula and dilatation and stenting of native coarctation.

  15. Mortality within the endovascular treatment in Stanford type B aortic dissections Mortalidade no tratamento endovascular nas dissecções aórticas tipo B

    Directory of Open Access Journals (Sweden)

    Alexandre Fioranelli

    2011-06-01

    Full Text Available BACKGROUND: Endovascular stent-graft repair of aortic dissections is a relatively new procedure, and although apparently less invasive, the efficacy and safety of this technique have not been fully established. OBJECTIVE: To evaluate mortality in patients with complicated Stanford type B aortic dissections submitted to endovascular treatment. METHODS: Clinical, anatomical, imaging and autopsy data of 23 patients with complicated type B aortic dissections were reviewed from November 2004 to October 2007. The main indications for transluminal thoracic stent-grafting included: persistent pain in spite of medical therapy, signs of distal limb ischemia, signs of aortic rupture, progression of aneurismal dilation of the descending aorta during follow-up (defined as a diameter > 50 mm and the diameter of descending thoracic aorta of 40mm or larger at the onset of aortic dissection. Data were analyzed statistically; all p-values were two-tailed and differences INTRODUÇÃO: O tratamento endovascular na dissecção de aorta é um procedimento relativamente novo e, embora aparentemente menos invasivo, a eficácia e a segurança dessa técnica não estão totalmente estabelecidas. OBJETIVO: Avaliar a mortalidade e complicações nos pacientes submetidos a tratamento endovascular na dissecção de aorta tipo B de Stanford. MÉTODOS: Foram revisados, a partir de novembro de 2004 a outubro de 2007, em estudo clínico, anatômico, de imagens e dados da autopsia de 23 pacientes com dissecção aórtica tipo B. As principais indicações para o procedimento foram: dor persistente apesar da terapia médica, sinais de isquemia distal do membro, sinais de ruptura da aorta, progressão da dilatação do aneurisma da aorta descendente, durante o seguimento (definida como um diâmetro > 5 cm e descendente da aorta torácica de 40 mm ou mais de diâmetro no início da dissecção aórtica. Os dados foram analisados estatisticamente considerados erro alfa de 5%. As vari

  16. Clinical evaluation of atherosclerosis and mechanical properties of the thoracic aorta

    International Nuclear Information System (INIS)

    Saiki, Atsushi

    1991-01-01

    To evaluate the aortic wall atherosclerosis, X-ray CT and ECG gated radionuclide angiography were performed in 25 subjects. They were classified into 17 normotensive group (N) and 8 hypertensive group (HT). The time-activity curve was generated using radionuclide angiography in the portion of the thoracic aorta. The aortic wall distensibility was expressed as 100ΔV/V 0 / PP, where ΔV was difference between maximum and minimum (V 0 ) counts of the aorta, and PP was pulse pressure. The degree of the aortic wall atherosclerosis was evaluated by X-ray CT. The aortic wall CT-score was calculated from the CT-scores measured whithin the region of interest of the other margin of the aorta and of the background by X-ray CT. There was a significant correlation between aortic wall CT-score and systolic blood pressure (r=0.59, p<0.01) or aortic wall distensibility (r=-0.74, p<0.01)), but no correlation existed between aortic wall CT-score and diastolic blood pressure (r=0.11, p:NS). The aortic wall distensibility was higher and the aortic wall CT-score was lower in N-group than in HT-group, whereas there was no difference of the radius of the aorta between both groups. These results suggest that the aortic wall atherosclerosis advanced progressively in hypertensive patients and systolic blood pressure was a good predictor of the degree of the aortic atherosclerosis. (author)

  17. Managment of thoracic empyema.

    Science.gov (United States)

    Sherman, M M; Subramanian, V; Berger, R L

    1977-04-01

    Over a ten year period, 102 patients with thoracic empyemata were treated at Boston City Hospital. Only three patients died from the pleural infection while twenty-six succumbed to the associated diseases. Priniciples of management include: (1) thoracentesis; (2) antibiotics; (3) closed-tube thoracostomy; (4) sinogram; (5) open drainage; (6) empyemectomy and decortication in selected patients; and (7) bronchoscopy and barium swallow when the etiology is uncertain.

  18. Thoracic textilomas: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Dianne Melo; Zanetti, Glaucia; Araujo Neto, Cesar Augusto; Nobre, Luiz Felipe; Meirelles, Gustavo de Souza Portes; Silva, Jorge Luiz Pereira e; Guimaraes, Marcos Duarte; Escuissato, Dante Luiz; Souza Junior, Arthur Soares; Hochhegger, Bruno; Marchiori, Edson, E-mail: edmarchiori@gmail.com [Hospital Universitario Antonio Pedro (HUAP/UFF), Niteroi, RJ (Brazil)

    2014-09-15

    Objective: the aim of this study was to analyze chest CT scans of patients with thoracic textiloma. Methods: this was a retrospective study of 16 patients (11 men and 5 women) with surgically confirmed thoracic textiloma. The chest CT scans of those patients were evaluated by two independent observers, and discordant results were resolved by consensus. Results: the majority (62.5%) of the textilomas were caused by previous heart surgery. The most common symptoms were chest pain (in 68.75%) and cough (in 56.25%). In all cases, the main tomographic finding was a mass with regular contours and borders that were well-defined or partially defined. Half of the textilomas occurred in the right hemithorax and half occurred in the left. The majority (56.25%) were located in the lower third of the lung. The diameter of the mass was ≤ 10 cm in 10 cases (62.5%) and > 10 cm in the remaining 6 cases (37.5%). Most (81.25%) of the textilomas were heterogeneous in density, with signs of calcification, gas, radiopaque marker, or sponge-like material. Peripheral expansion of the mass was observed in 12 (92.3%) of the 13 patients in whom a contrast agent was used. Intraoperatively, pleural involvement was observed in 14 cases (87.5%) and pericardial involvement was observed in 2 (12.5%). Conclusions: it is important to recognize the main tomographic aspects of thoracic textilomas in order to include this possibility in the differential diagnosis of chest pain and cough in patients with a history of heart or thoracic surgery, thus promoting the early identification and treatment of this postoperative complication. (author)

  19. Valve-sparing aortic root replacement†.

    Science.gov (United States)

    Koolbergen, David R; Manshanden, Johan S J; Bouma, Berto J; Blom, Nico A; Mulder, Barbara J M; de Mol, Bas A J M; Hazekamp, Mark G

    2015-02-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed. Median age was 40.3 (range: 13.4-68.6) years and 67 (69.1%) were male. Seven (7.2%) patients were younger than 18 years, the youngest being 13.4 years. Fifty-four (55.7%) had Marfan syndrome, 2 (2.1%) other fibrous tissue diseases, 15 (15.5%) bicuspid aortic valve and 3 (3.1%) had earlier Fallot repair. The reimplantation technique was used in all, with a straight vascular prosthesis in 11 (26-34 mm) and the Valsalva prosthesis in 86 (26-32 mm). Concomitant aortic valve repair was performed in 43 (44.3%), mitral valve repair in 10 (10.3%), tricuspid valve repair in 5 (5.2%) and aortic arch replacement in 3 (3.1%). Mean follow-up was 4.2 ± 2.4 years. Follow-up was complete in all. One 14-year old patient died 1.3 years post-surgery presumably of ventricular arrhythmia. One patient underwent reoperation for aneurysm of the proximal right coronary artery after 4.9 years and 4 patients required aortic valve replacement, 3 of which because of endocarditis after 0.1, 0.8 and 1.3 years and 1 because of cusp prolapse after 3.8 years. No thrombo-embolic complications occurred. Mortality, root reoperation and aortic regurgitation were absent in 88.0 ± 0.5% at 5-year follow-up. Results of valve-sparing root replacement are good, even in association with a high incidence of concomitant valve repair. Valve-sparing aortic root replacement can be performed at a very young age as long as an adult size prosthesis can be implanted. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. A geometric approach to aortic root surgical anatomy.

    Science.gov (United States)

    Contino, Monica; Mangini, Andrea; Lemma, Massimo Giovanni; Romagnoni, Claudia; Zerbi, Pietro; Gelpi, Guido; Antona, Carlo

    2016-01-01

    The aim of this study was the analysis of the geometrical relationships between the different structures constituting the aortic root, with particular attention to interleaflet triangles, haemodynamic ventriculo-arterial junction and functional aortic annulus in normal subjects. Sixteen formol-fixed human hearts with normal aortic roots were studied. The aortic root was isolated, sectioned at the midpoint of the non-coronary sinus, spread apart and photographed by a high-resolution digital camera. After calibration and picture resizing, the software AutoCAD 2004 was used to identify and measure all the elements of the interleaflets triangles and of the aortic root that were objects of our analysis. Multiple comparisons were performed with one-way analysis of variance for continuous data and with Kruskal-Wallis analysis for non-continuous data. Linear regression and Pearson's product correlation were used to correlate root element dimensions when appropriate. Student's t-test was used to compare means for unpaired data. Heron's formula was applied to estimate the functional aortic annular diameters. The non coronary-left coronary interleaflets triangles were larger, followed by inter-coronary and right-non-coronary ones. The apical angle is <60° and its standard deviation can be considered an asymmetry index. The sinu-tubular junction was shown to be 10% larger than the virtual basal ring (VBR). The mathematical relationship between the haemodynamic ventriculo-arterial junction and the VBR calculated by linear regression and expressed in terms of the diameter was: haemodynamic ventriculo-arterial junction = 2.29 VBR (diameter) + 47. Conservative aortic surgery is based on a better understanding of aortic root anatomy and physiology. The relationships among its elements are of paramount importance during aortic valve repair/sparing procedures and they can be useful also in echocardiographic analysis and in computed tomography reconstruction. © The Author 2015

  1. Different transcatheter strategies for aortic coarctation associated with patent ductus arteriosus

    Directory of Open Access Journals (Sweden)

    Anil Kumar Singhi

    2012-07-01

    Conclusions: In coarctation with patent ductus arteriosus associated with good sized aortic isthmus, closure of duct with duct occluder device and balloon aortoplasty would correct the lesions. If there is isthmic hypoplasia, device closure of the duct and stenting of the coarctation is needed. Covered stent is a reasonable alternative only in presence of non dilated descending aorta.

  2. Disruptive technology in the treatment of thoracic trauma.

    Science.gov (United States)

    Smith, R Stephen

    2013-12-01

    The care of patients with thoracic injuries has undergone monumental change over the past 25 years. Advances in technology have driven improvements in care, with obvious benefits to patients. In many instances, new or "disruptive" technologies have unexpectedly displaced previously established standards for the diagnosis and treatment of these potentially devastating injuries. Examples of disruptive technology include the use of ultrasound technology for the diagnosis of cardiac tamponade and pneumothorax; thoracoscopic techniques instead of thoracotomy, pulmonary tractotomy, and stapled lung resection; endovascular repair of thoracic aortic injury; operative fixation of flail chest; and the enhanced availability of extracorporeal lung support for severe respiratory failure. Surgeons must be prepared to recognize the benefits, and limits, of novel technologies and incorporate these methods into day-to-day treatment protocols. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Angular (Gothic) aortic arch leads to enhanced systolic wave reflection, central aortic stiffness, and increased left ventricular mass late after aortic coarctation repair: evaluation with magnetic resonance flow mapping.

    Science.gov (United States)

    Ou, Phalla; Celermajer, David S; Raisky, Olivier; Jolivet, Odile; Buyens, Fanny; Herment, Alain; Sidi, Daniel; Bonnet, Damien; Mousseaux, Elie

    2008-01-01

    We sought to investigate the mechanism whereby a particular deformity of the aortic arch, an angulated Gothic shape, might lead to hypertension late after anatomically successful repair of aortic coarctation. Fifty-five normotensive patients with anatomically successful repair of aortic coarctation and either a Gothic (angulated) or a Romanesque (smooth and rounded) arch were studied with magnetic resonance angiography and flow mapping in both the ascending and descending aortas. Systolic waveforms, central aortic stiffness, and pulse velocity were measured. We hypothesized that arch angulation would result in enhanced systolic wave reflection with loss of energy across the aortic arch, as well as increased central aortic stiffness. Twenty patients were found to have a Gothic, and 35 a Romanesque, arch. Patients with a Gothic arch showed markedly augmented systolic wave reflection (12 +/- 6 vs 5 +/- 0.3 mL, P Gothic arch (5.6 +/- 1.1 vs 4.1 +/- 1 m/s, P Gothic aortic arch is associated with increased systolic wave reflection, as well as increased central aortic stiffness and left ventricular mass index. These findings explain (at least in part) the association between this pattern of arch geometry and late hypertension at rest and on exercise in subjects after coarctation repair.

  4. Inverted Lymphoglandular Polyp in Descending Colon

    Directory of Open Access Journals (Sweden)

    Shengmei Zhou

    2015-01-01

    Full Text Available A 47-year-old male with a history of left colon cancer, status post left colon resection for 12 years, presented with rectal bleeding. Colonoscopic examination revealed an 8 mm sessile polyp in the proximal descending colon. Microscopic examination showed that the surface of this polyp was covered with a layer of normal colonic mucosa with focal surface erosion. In the submucosal layer, an intimate admixture of multiple cystically dilated glands and prominent lymphoid aggregates with germinal centers was seen. The glands were lined by columnar epithelium. Immunohistochemical staining showed the glands were positive for CK20 and CDX2 and negative for CK7, with a low proliferative index, mostly consistent with reactive colonic glands. The patient remained asymptomatic after one-year follow-up. A review of the literature shows very rare descriptions of similar lesions, but none fits exactly this pattern. We would designate this inverted lymphoglandular polyp and present this case to raise the awareness of recognizing this unusual histological entity.

  5. Effects of thapsigargin in isolated rat thoracic aorta

    DEFF Research Database (Denmark)

    Mikkelsen, E O; Thastrup, Ole; Christensen, S B

    1988-01-01

    The effect of thapsigargin (Tg) was studied in rat thoracic aorta. Tg (10(-8)-10(-5) M) had a dual effect on rat aorta. Thus, Tg induced a concentration dependent increase in basal tone in normal physiological salt solution (PSS), while Tg in potassium (K+) precontracted aortic rings caused a con...... A 23187 had an endothelium dependent relaxant effect on rat aorta different from that of carbachol. The results indicate that Tg in vascular smooth muscle acts by stimulating the transmembranal influx of extracellular calcium....

  6. MRI assessment of thoracic stent grafts after emergency implantation in multi trauma patients: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Rasche, Volker [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); University Hospital Ulm, University of Ulm, Department of Internal Medicine II, Ulm (Germany); Oberhuber, Alexander; Orend, Karl-Heinz [University Hospital Ulm, Department of Vascular and Thoracic Surgery, Ulm (Germany); Trumpp, Stephan [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); University Hospital Ulm, Department of Vascular and Thoracic Surgery, Ulm (Germany); Bornstedt, Axel; Merkle, Nico; Rottbauer, Wolfgang [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); Hoffmann, Martin [University Hospital Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany)

    2011-07-15

    To evaluate the feasibility of MRI for static and dynamic assessment of the deployment of thoracic aortic stent grafts after emergency implantation in trauma patients. Twenty patients initially presenting with a rupture of the thoracic aorta were enrolled in this study. All patients underwent thoracic endovascular aortic repair (TEVAR). The deployment of the implanted stent graft was assessed by CTA and MRI, comprising the assessment of the aortic arch with and without contrast agent, and the assessment of the motion of the stent graft over the cardiac cycle. The stent graft geometry and motion over the cardiac cycle were assessable by MRI in all patients. Flow-mediated signal variations in areas of flow acceleration could be well visualised. No statistically significant differences in stent-graft diameters were observed between CT and MRI measurements. MRI appears to be a valuable tool for the assessment of thoracic stent grafts. It shows similar performance in the accurate assessment of stent-graft dimensions to the current gold standard CTA. Its capability of providing additional functional information and the lack of ionising radiation and nephrotoxic contrast agents may make MRI a valuable tool for monitoring patients after TEVAR. (orig.)

  7. Customized CT angiogram planning for intraoperative transesophageal echography-guided endovascular exclusion of thoracic aorta penetrating ulcer.

    Science.gov (United States)

    Piazza, Michele; Lupia, Mario; Grego, Franco; Antonello, Michele

    2015-04-01

    The technique is demonstrated in a 78-year-old man; the preoperative CT angiogram showed a descending thoracic aorta ulcer of 5.9 cm in maximum diameter and 3.8 cm longitudinal extension. A ZTEG-2P-36-127-PF (Cook Medical) single tubular endograft was planned to be deployed. From the preoperative CT angiogram we planned to land 4.7 cm above the midline of the descending thoracic aorta ulcer and 8.0 cm below. In the operating room, under radioscopic vision the centre of the transesophageal echography probe was used as marker to identify the correspondent midline of the descending thoracic aorta ulcer and a centimeter-sized pigtail catheter in the aorta was used to calculate the desired length above and below the ulcer midline. The endograft was introduced and placed in the desired position compared to the transesophageal echography probe and the catheter; under transesophageal echography vision the graft was finally deployed. The CT angiogram at 1 month showed the correct endograft position, descending thoracic aorta ulcer exclusion with no signs of endoleak. In selected cases, this method allows planning in advance safe stent graft positioning and deployment totally assisted by transesophageal echography, with no risk of periprocedural contrast-related renal failure and reduced radiation exposure for the patient and operators. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  8. A comparison of minimally invasive and standard aortic valve replacement.

    Science.gov (United States)

    Stoliński, Jarosław; Plicner, Dariusz; Grudzień, Grzegorz; Wąsowicz, Marcin; Musiał, Robert; Andres, Janusz; Kapelak, Bogusław

    2016-10-01

    The study objective was to compare aortic valve replacement through a right anterior minithoracotomy with aortic valve replacement through a median sternotomy. With propensity score matching, we selected 211 patients after aortic valve replacement through a right anterior minithoracotomy and 211 patients after aortic valve replacement who underwent operation between January 2010 and December 2013. Perioperative outcomes were analyzed, and multivariable logistic regression analysis of risk factors of postoperative morbidity was performed. For propensity score-matched patients, hospital mortality was 1.0% in the aortic valve replacement through a right anterior minithoracotomy group and 1.4% in the aortic valve replacement group (P = 1.000). Stroke occurred in 0.5% versus 1.4% (P = .615), myocardial infarction occurred in 1.4% versus 1.9% (P = 1.000), and new onset of atrial fibrillation occurred in 12.8% versus 24.2% (P = .003) of patients in the aortic valve replacement through a right anterior minithoracotomy and aortic valve replacement groups, respectively. Postoperative drainage was 353.5 ± 248.6 mL versus 544.3 ± 324.5 mL (P replacement through a right anterior minithoracotomy and aortic valve replacement groups, respectively. Mediastinitis occurred in 2.8% of patients after aortic valve replacement and in 0.0% of patients after aortic valve replacement through a right anterior minithoracotomy surgery (P = .040). Intensive care unit stay (1.3 ± 1.2 days vs 2.6 ± 2.6 days) and hospital stay (5.7 ± 1.6 days vs 8.7 ± 4.4 days) were statistically significantly shorter in the aortic valve replacement through a right anterior minithoracotomy group. Aortic valve replacement through a right anterior minithoracotomy surgery resulted in reduced postoperative morbidity (odds ratio, 0.4; P replacement through a right anterior minithoracotomy surgery resulted in a reduced infection rate, diminished postoperative bleeding and blood

  9. Descending Necrotizing Mediastinitis Treated with Tooth Extractions following Mediastinal and Cervical Drainage

    Directory of Open Access Journals (Sweden)

    Minoru Fukuchi

    2015-10-01

    Full Text Available Descending necrotizing mediastinitis (DNM is a rare condition in which oropharyngeal infection spreads to the mediastinum via the cervical fascia. Delayed diagnosis and surgery result in a high mortality rate among patients with DNM. We present a case of DNM resulting from odontogenic infection treated successfully with tooth extraction following mediastinal and cervical drainage. A 43-year-old, previously healthy Japanese man was admitted to our hospital for treatment of acute mediastinitis. Computed tomography revealed gas collection around the mid-thoracic esophagus and bilateral pleural effusion. We performed mediastinal drainage via right thoracotomy. Cervicotomy was performed on postoperative day 14 to drain a residual cervical abscess. The patient required the extraction of ten teeth over three procedures to address primary odontogenic infection before his fever resolved on postoperative day 40. Prompt diagnosis, aggressive drainage and removal of the source of infection can improve survival among patients with this life-threatening disease.

  10. Atypical Presentation of Traumatic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Andrew Fu Wah Ho

    2014-01-01

    Full Text Available Background. Blunt thoracic aorta injury (BAI is second only to head injury as cause of mortality in blunt trauma. While most patients do not survive till arrival at the hospital, for the remainder, prompt diagnosis and treatment greatly improve outcomes. We report an atypical presentation of BAI, highlighting the diagnostic challenges of this condition in the emergency department. Case Presentation. A previously well 25-year-old male presented 15 hours after injury hemodynamically stable with delirium. There were no signs or symptoms suggestive of BAI. Sonography showed small bilateral pleural effusions. Chest radiograph showed a normal mediastinum. Eventually, CT demonstrated a contained distal aortic arch disruption. The patient underwent percutaneous endovascular thoracic aortic repair and recovered well. Conclusion. This catastrophic lesion may present with few reliable signs and symptoms; hence, a high index of suspicion is crucial for early diagnosis and definitive surgical management. This paper discusses the diagnostic utility of clinical features, injury mechanism, and radiographic modalities. Consideration of mechanism of injury, clinical features, and chest radiograph findings should prompt advanced chest imaging.

  11. A combinatorial approach for analyzing the number of descendants ...

    African Journals Online (AJOL)

    This work is devoted to a study of the number of descendants of node j in random increasing trees, previously treated in [5, 8, 10, 15], and also to a study of the number of descendants of node j in pairs of random trees generated by a certain growth process generalizing the corresponding analysis of various classes of ...

  12. Endovascular repair of aortic disease: a venture capital perspective.

    Science.gov (United States)

    Buchanan, Lucas W; Stavropoulos, S William; Resnick, Joshua B; Solomon, Jeffrey

    2009-03-01

    Endovascular devices for the treatment of abdominal and thoracic aortic disease are poised to become the next $1 billion medical device market. A shift from open repair to endovascular repair, advances in technology, screening initiatives, and new indications are driving this growth. Although billion-dollar medical device markets are rare, this field is fraught with risk and uncertainty for startups and their venture capital investors. Technological hurdles, daunting clinical and regulatory timelines, market adoption issues, and entrenched competitors pose significant barriers to successful new venture creation. In fact, the number of aortic endografts that have failed to reach commercialization or have been pulled from the market exceeds the number of Food and Drug Administration-approved endografts in the United States. This article will shed some light on the venture capital mind-set and decision-making paradigm in the context of aortic disease.

  13. Long-term results of aortic root repair using the reimplantation technique.

    Science.gov (United States)

    David, Tirone E; Armstrong, Susan; Manlhiot, Cedric; McCrindle, Brian W; Feindel, Christopher M

    2013-03-01

    Aortic valve sparing is frequently performed to treat patients with aortic root aneurysm, but there is an inadequate amount of information regarding its long-term durability. This study examines the long-term results of reimplantation of the aortic valve in patients with aortic root aneurysms. From August 1989 to December 2010, 296 consecutive patients had reimplantation of the aortic valve into a tubular Dacron graft. Their mean age was 45 years (range, 11-79 years), and 78% were men. Of the patients, 36% had Marfan syndrome and 11% had bicuspid aortic valve. Patients were followed prospectively with periodic images of the aortic root and remaining aorta. The mean follow-up was 6.9 ± 4.5 years. There were 21 patients at risk at 15 years. There were 4 operative and 18 late deaths. The survival at 5, 10, and 15 years was 95.1% ± 3.5%, 93.1% ± 4.4%, and 76.5% ± 18%, respectively. Only 3 patients required reoperation on the aortic valve; all 3 patients had the Bentall procedure. Freedom from reoperation at 5, 10, and 15 years was 99.7% ± 2.0%, 97.8% ± 5.3%, and 97.8% ± 5.3%, respectively. During follow-up, moderate aortic insufficiency developed in 9 patients, and severe aortic insufficiency developed in 2 patients. Freedom from moderate or severe aortic insufficiency at 5, 10, and 15 years was 98.3% ± 3.5%, 92.9% ± 6.5%, and 89.4% ± 12%, respectively. The function of the aortic valve implanted inside a tubular Dacron graft remains normal at 15 years in most patients after this type of aortic valve-sparing operation. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  14. IV DSA in the diagnosis and follow-up of dissection of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Hendrickx, P.; Luska, G.; Laas, J.; Haverich, A.

    1986-05-01

    Intravenous DSA was performed in 53 patients with suspected dissection of the thoracic aorta and in 13 patients following surgery for aortic dissection. In 36 patients, the suspected diagnosis could be excluded definitely and, in 14 cases out of 17, a dissection was correctly diagnosed. All 11 type B dissections were correctly diagnosed. Of six type A dissections, only three were adequately demonstrated by IV DSA. In type B dissections, IV DSA is reliable, but in type A dissection with massive aortic insufficiency or pericardial tamponade the findings are not reliable. In all 13 patients who had surgery for dissection, IV DSA proved suitable for showing the anastomosis and progress of the disease.

  15. Thoracic organ transplantation.

    Science.gov (United States)

    Pierson, Richard N; Barr, Mark L; McCullough, Keith P; Egan, Thomas; Garrity, Edward; Jessup, Mariell; Murray, Susan

    2004-01-01

    This article presents an overview of factors associated with thoracic transplantation outcomes over the past decade and provides valuable information regarding the heart, lung, and heart-lung waiting lists and thoracic organ transplant recipients. Waiting list and post-transplant information is used to assess the importance of patient demographics, risk factors, and primary cardiopulmonary disease on outcomes. The time that the typical listed patient has been waiting for a heart, lung, or heart-lung transplant has markedly increased over the past decade, while the number of transplants performed has declined slightly and survival after transplant has plateaued. Waiting list mortality, however, appears to be declining for each organ and for most diseases and high-severity subgroups, perhaps in response to recent changes in organ allocation algorithms. Based on perceived inequity in organ access and in response to a mandate from Health Resources and Services Administration, the lung transplant community is developing a lung allocation system designed to minimize deaths on the waiting list while maximizing the benefit of transplant by incorporating post-transplant survival and quality of life into the algorithm. Areas where improved data collection could inform evolving organ allocation and candidate selection policies are emphasized.

  16. Thoracic damage control surgery.

    Science.gov (United States)

    Gonçalves, Roberto; Saad, Roberto

    2016-01-01

    The damage control surgery came up with the philosophy of applying essential maneuvers to control bleeding and abdominal contamination in trauma patients who are within the limits of their physiological reserves. This concept was extended to thoracic injuries, where relatively simple maneuvers can shorten operative time of in extremis patients. This article aims to revise the various damage control techniques in thoracic organs that must be known to the surgeon engaged in emergency care. RESUMO A cirurgia de controle de danos surgiu com a filosofia de se aplicar manobras essenciais para controle de sangramento e contaminação abdominal, em doentes traumatizados, nos limites de suas reservas fisiológicas. Este conceito se estendeu para as lesões torácicas, onde manobras relativamente simples, podem abreviar o tempo operatório de doentes in extremis. Este artigo tem como objetivo, revisar as diversas técnicas de controle de dano em órgãos torácicos, que devem ser de conhecimento do cirurgião que atua na emergência.

  17. 78 FR 36702 - Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems (IABP) for...

    Science.gov (United States)

    2013-06-19

    .... FDA-2013-N-0581] Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems... Device In the preamble to the proposed rule (44 FR 13369; March 9, 1979), the Cardiovascular Device... Bypass Grafting: A Propensity Score Analysis,'' Interactive Cardiovascular and Thoracic Surgery, vol. 9...

  18. Aortic dimensions in girls and young women with turner syndrome: a magnetic resonance imaging study

    DEFF Research Database (Denmark)

    Cleemann, Line; Mortensen, Kristian H; Holm, Kirsten

    2010-01-01

    This study aimed to determine the dimensions of the thoracic aorta and the predictors of aortic dimensions in girls and young women with Turner syndrome (TS). A cross-sectional study was performed at a secondary care center. The study compared 41 TS patients with 50 healthy age-matched control...

  19. Traumatic partial avulsion of a single right subclavian artery from the aortic arch and definitive repair.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Sears-Rogan, Pamela; Young, Richard S; Kanda, Louis T; Ellis, Jennifer L

    2006-01-01

    Blunt injury to the right subclavian artery is a rare complication of severe deceleration trauma often associated with significant morbidity and mortality. We describe an atypical presentation in a patient who sustained a traumatic avulsion of his right subclavian artery arising off the aortic arch. An interposition graft was used to restore the continuity of the artery to the ascending thoracic aorta.

  20. Late type III endoleak after thoracic endovascular aneurysm repair and previous infrarenal stent graft implantation - a case report and review of the literature.

    Science.gov (United States)

    Leszczyński, Jerzy; Macioch, Waldemar; Chudziński, Witold; Gałązka, Zbigniew

    2017-09-01

    Thoracic endovascular aortic repair (TEVAR) effectively improved the results of thoracic aortic aneurysm treatment. TEVAR is a less invasive procedure that can be performed under local anesthesia with shorter hospital stay. The perioperative morbidity and mortality rates are lower for endovascular than open repair, but the rate of secondary interventions is higher for TEVAR. We report a case of an elderly man with synchronous abdominal and thoracic aortic aneurysms. A type III dangerous endoleak was recognized 3 years after TEVAR. It was successfully repaired during an endovascular procedure. There were no new endoleaks after 12 months of follow-up. TEVAR may be the only option of treatment for risky and elderly patients. However, postoperative monitoring is necessary to exclude different types of endoleaks. Most of them undergo effective endovascular repair.

  1. Thoracic spine x-ray

    Science.gov (United States)

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  2. Contemporary spinal cord protection during thoracic and thoracoabdominal aortic surgery and endovascular aortic repair

    DEFF Research Database (Denmark)

    Etz, Christian D; Weigang, Ernst; Hartert, Marc

    2015-01-01

    devastating complication. The aim of this position paper is to provide physicians with broad information regarding spinal cord blood supply, to share strategies for shortening intraprocedural spinal cord ischaemia and to increase spinal cord tolerance to transitory ischaemia through detection of ischaemia...... publications available in the PubMed database, which are cohort studies, experimental research reports, case reports, reviews, short series and meta-analyses. Individual chapters of this position paper were assigned and after delivery harmonized by Christian D. Etz, Ernst Weigang and Martin Czerny....... Consequently, further writing assignments were distributed within the group and delivered in August 2014. The final version was submitted to the EJCTS for review in September 2014....

  3. Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 2).

    Science.gov (United States)

    Piazza, Nicolo; Bleiziffer, Sabine; Brockmann, Gernot; Hendrick, Ruge; Deutsch, Marcus-André; Opitz, Anke; Mazzitelli, Domenico; Tassani-Prell, Peter; Schreiber, Christian; Lange, Rüdiger

    2011-07-01

    This study sought to review the acute procedural outcomes of patients who underwent transcatheter aortic valve (TAV)-in-surgical aortic valve (SAV) implantation at the German Heart Center, Munich, and to summarize the existing literature on TAV-in-SAV implantation (n = 47). There are several case reports and small case series describing transcatheter aortic valve implantation for a failing surgical aortic valve bioprosthesis (TAV-in-SAV implantation). From January 2007 to March 2011, 20 out of 556 patients underwent a TAV-in-SAV implantation at the German Heart Center Munich. Baseline characteristics and clinical outcome data were prospectively entered into a dedicated database. The mean patient age was 75 ± 13 years, and the mean logistic European System for Cardiac Operative Risk Evaluation and Society of Thoracic Surgeons' Risk Model scores were 27 ± 13% and 7 ± 4%, respectively. Of the 20 patients, 14 had stented and 6 had stentless surgical bioprostheses. Most cases (12 of 20) were performed via the transapical route using a 23-mm Edwards Sapien prosthesis (Edwards Lifesciences, Irvine, California). Successful implantation of a TAV in a SAV with the patient leaving the catheterization laboratory alive was achieved in 18 of 20 patients. The mean transaortic valve gradient was 20.0 ± 7.5 mm Hg. None-to-trivial, mild, and mild-to-moderate paravalvular aortic regurgitation was observed in 10, 6, and 2 patients, respectively. We experienced 1 intraprocedural death following pre-implant balloon aortic valvuloplasty ("stone heart") and 2 further in-hospital deaths due to myocardial infarction. TAV-in-SAV implantation is a safe and feasible treatment for high-risk patients with failing aortic bioprosthetic valves and should be considered as part of the armamentarium in the treatment of aortic bioprosthetic valve failure. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Aortic arch malformations

    Energy Technology Data Exchange (ETDEWEB)

    Kellenberger, Christian J. [University Children' s Hospital, Department of Diagnostic Imaging, Zuerich (Switzerland)

    2010-06-15

    Although anomalies of the aortic arch and its branches are relatively uncommon malformations, they are often associated with congenital heart disease. Isolated lesions may be clinically significant when the airways are compromised by a vascular ring. In this article, the development and imaging appearance of the aortic arch system and its various malformations are reviewed. (orig.)

  5. Imaging in aortic dissection

    International Nuclear Information System (INIS)

    Yu-Qing Liu, M.D.

    1995-01-01

    Aortic dissection (AD) is a catastrophic aortic disease. Imaging techniques play an invaluable role in the diagnostic evaluation and management of patients with AD. Major signs of AD with different imaging modalities are described in this article with a pertinent discussion on guidelines for the optimized approach of imaging study (13 refs.)

  6. Aortic arch malformations

    International Nuclear Information System (INIS)

    Kellenberger, Christian J.

    2010-01-01

    Although anomalies of the aortic arch and its branches are relatively uncommon malformations, they are often associated with congenital heart disease. Isolated lesions may be clinically significant when the airways are compromised by a vascular ring. In this article, the development and imaging appearance of the aortic arch system and its various malformations are reviewed. (orig.)

  7. Imaging in aortic dissection

    Energy Technology Data Exchange (ETDEWEB)

    Yu-Qing Liu, M D [Chinese Academy of Medical Sciences, Beijing, BJ (China). Dept. of Radiology, Fu Wai Hospital and Cardiovascular Inst.

    1996-12-31

    Aortic dissection (AD) is a catastrophic aortic disease. Imaging techniques play an invaluable role in the diagnostic evaluation and management of patients with AD. Major signs of AD with different imaging modalities are described in this article with a pertinent discussion on guidelines for the optimized approach of imaging study (13 refs.).

  8. Disección de aorta: Aspectos básicos y manejo endovascular Aortic dissection: Basic aspects and endovascular management

    Directory of Open Access Journals (Sweden)

    Nicolás I Jaramillo

    2005-08-01

    , probablemente llegue a ser la terapia preferida, aunque la técnica todavía está en proceso de refinamiento. A nivel mundial la experiencia viene en crecimiento y hoy se entienden mejor las indicaciones y las limitaciones de esta terapia innovadora. En este artículo se hace una revisión general sobre el diagnóstico clínico y el manejo de la disección aórtica y sus variantes: el hematoma intramural y la úlcera aórtica aterosclerótica.Treatment of thoracic aortic pathology is complicated by the morbidity associated to the surgical procedure and to the frailty of an elderly and difficult population. Surgical operation in this kind of population frequently bears a significant incidence of death and long term disability. In an effort to reduce the incidence of negative outcomes, minimally invasive techniques in the form of endovascular stenting have been introduced during the past decade. The technology, originally described by Parodi, and initially designed for its use in abdominal aortic aneurysms, has been adapted for the treatment of thoracic aortic aneurysms. Furthermore, an improved understanding of the pathophysiology and the natural history of thoracic aortic disease as well as the analysis of the outcomes has facilitated our treatment decisions in terms of the timing for an appropriate intervention. Treatment of thoracic aortic dissection using endovascular stent is one of the more recent advances in this condition and is receiving increasing attention as it is a less invasive alternative to an open surgical repair. Although this technology is still innovative, significant improvements have been made lately in the design and deployment of the endovascular stent-grafts. These prostheses have been increasingly used to treat aneurysms, dissections and traumatic ruptures, as well as giant penetrating ulcers and intramural hematomas of the descending thoracic aorta with good early and mid-term outcomes. The rareness, complexity and severity of the pathology and the

  9. Over 20 years experience with aortic homograft in aortic valve replacement during acute infective endocarditis.

    Science.gov (United States)

    Solari, Silvia; Mastrobuoni, Stefano; De Kerchove, Laurent; Navarra, Emiliano; Astarci, Parla; Noirhomme, Philippe; Poncelet, Alain; Jashari, Ramadan; Rubay, Jean; El Khoury, Gebrine

    2016-12-01

    Despite the controversy, the aortic homograft is supposedly the best option in acute infective endocarditis (AIE), due to its resistance to reinfection. However, the technical complexity and the risk of structural deterioration over time have limited its utilization. The aim of this study was to evaluate the long-term results of aortic homograft for the treatment of infective endocarditis in our institution with particular attention to predictors of survival and homograft reoperation. The cohort includes 112 patients who underwent aortic valve replacement with an aortic homograft for AIE between January 1990 and December 2014. Fifteen patients (13.4%) died during the first 30 days after the operation. Two patients were lost to follow-up after discharge from the hospital; therefore, 95 patients were available for long-term analysis. The median duration of follow-up was 7.8 years (IQR 4.7-17.6). Five patients (5.3%) suffered a recurrence of infective endocarditis (1 relapse and 4 new episodes). Sixteen patients (16.8%) were reoperated for structural valve degeneration (SVD; n = 14, 87.5%) or for infection recurrence (n = 2, 12.5%). Freedom from homograft reoperation for infective endocarditis or structural homograft degeneration at 10 and 15 years postoperatively was 86.3 ± 5.5 and 47.3 ± 11.0%, respectively. For patients requiring homograft reoperation, the median interval to reintervention was 11.6 years (IQR 8.3-14.5). Long-term survival was 63.6% (95% CI 52.4-72.8%) and 53.8% (95% CI 40.6-65.3%) at 10 and 15 years, respectively. The use of aortic homograft in acute aortic valve endocarditis is associated with a remarkably low risk of relapsing infection and very acceptable long-term survival. The risk of reoperation due to SVD is significant after one decade especially in young patients. The aortic homograft seems to be ideally suited for reconstruction of the aortic valve and cardiac structures damaged by the infective process especially in early surgery.

  10. Early and medium term results of the sleeve valve-sparing procedure for aortic root ectasia.

    Science.gov (United States)

    Gamba, Amando; Tasca, Giordano; Giannico, Floriana; Lobiati, Elisabetta; Skouse, Douglas; Galanti, Andrea; Martino, Antonello Stefano; Triggiani, Michele

    2015-04-01

    The aim of this retrospective study was to evaluate our experience of using a simplified aortic valve sleeve procedure to treat aortic root ectasia and aneurysms with or without aortic regurgitation. In experienced hands, 2 aortic valve-sparing procedures, ie, Yacoub and David, have yielded excellent long-term results in the treatment of aortic root aneurysms, with or without aortic regurgitation. However, these techniques are demanding and not widely used. Recently, a new and simplified valve-sparing technique, named "sleeve procedure," has been proposed, and has yielded encouraging early results. Ninety consecutive patients with aortic root aneurysms underwent sleeve procedures from October 2006 to October 2012. Follow-up data (clinical 100% complete and echocardiographic 93% complete) were acquired from our outpatient clinic or from the referring cardiologist. The mean age of the patients was 61.5 ± 12.5 years, 79% were male, 16 (18%) had a bicuspid valve, 3 had Marfan syndrome, and 2 had aortic dissection. Over a mean clinical follow-up of 34 ± 19 months, 2 patients died from noncardiac causes and 1 was reoperated on for the recurrence of aortic regurgitation. On follow-up echocardiography after a mean of 18 ± 9 months, aortic regurgitation was absent/negligible, mild or moderate in 62%, 37%, and 1% of patients, respectively, and the diameters of the annulus, Valsalva sinuses, and sinotubular junction were 27.3 + 2.2, 37.0 + 3.4, and 30.6 + 3.1 mm, respectively. Our encouraging early and medium term results suggest that the sleeve procedure is a safe and effective aortic valve-sparing technique for the treatment of aortic root ectasia and aneurysm. However, longer follow-up is needed in order to draw definitive conclusions. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Bovine aortic arch with supravalvular aortic stenosis.

    Science.gov (United States)

    Idhrees, Mohammed; Cherian, Vijay Thomas; Menon, Sabarinath; Mathew, Thomas; Dharan, Baiju S; Jayakumar, K

    2016-09-01

    A 5-year-old boy was diagnosed to have supravalvular aortic stenosis (SVAS). On evaluation of CT angiogram, there was associated bovine aortic arch (BAA). Association of BAA with SVAS has not been previously reported in literature, and to best of our knowledge, this is the first case report of SVAS with BAA. Recent studies show BAA as a marker for aortopathy. SVAS is also an arteriopathy. In light of this, SVAS can also possibly be a manifestation of aortopathy associated with BAA. Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  12. Bovine aortic arch with supravalvular aortic stenosis

    Directory of Open Access Journals (Sweden)

    Mohammed Idhrees

    2016-09-01

    Full Text Available A 5-year-old boy was diagnosed to have supravalvular aortic stenosis (SVAS. On evaluation of CT angiogram, there was associated bovine aortic arch (BAA. Association of BAA with SVAS has not been previously reported in literature, and to best of our knowledge, this is the first case report of SVAS with BAA. Recent studies show BAA as a marker for aortopathy. SVAS is also an arteriopathy. In light of this, SVAS can also possibly be a manifestation of aortopathy associated with BAA.

  13. Thoracic vasculitis pre