WorldWideScience

Sample records for dental implant stability

  1. Electromechanical impedance method to assess dental implant stability

    International Nuclear Information System (INIS)

    Tabrizi, Aydin; Rizzo, Piervincenzo; Ochs, Mark W

    2012-01-01

    The stability of a dental implant is a prerequisite for supporting a load-bearing prosthesis and establishment of a functional bone–implant system. Reliable and noninvasive methods able to assess the bone interface of dental and orthopedic implants (osseointegration) are increasingly demanded for clinical diagnosis and direct prognosis. In this paper, we propose the electromechanical impedance method as a novel approach for the assessment of dental implant stability. Nobel Biocare ® implants with a size of 4.3 mm diameter ×13 mm length were placed inside bovine bones that were then immersed in a solution of nitric acid to allow material degradation. The degradation simulated the inverse process of bone healing. The implant–bone systems were monitored by bonding a piezoceramic transducer (PZT) to the implants’ abutment and measuring the admittance of the PZT over time. It was found that the PZT’s admittance and the statistical features associated with its analysis are sensitive to the degradation of the bones and can be correlated to the loss of calcium measured by means of the atomic absorption spectroscopy method. The present study shows promising results and may pave the road towards an innovative approach for the noninvasive monitoring of dental implant stability and integrity. (paper)

  2. Methods to measure stability of dental implants

    Directory of Open Access Journals (Sweden)

    Shruti Digholkar

    2014-01-01

    Full Text Available Dental implant treatment is an excellent option for prosthetic restoration that is associated with high success rates. Implant stability is essential for a good outcome. The clinical assessment of osseointegration is based on mechanical stability rather than histological criteria, considering primary stability (absence of mobility in bone bed after implant insertion and secondary stability (bone formation and remodeling at implant-bone interface. However, due to the invasive nature of the histological methods various other methods have been proposed: Radiographs, the surgeon′s perception, Insertion torque (cutting torque analysis, seating torque, reverse torque testing, percussion testing, impact hammer method, pulsed oscillation waveform, implant mobility checker, Periotest, resonance frequency analysis. This review focuses on the methods currently available for the evaluation of implant stability.

  3. Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis.

    Science.gov (United States)

    Atieh, Momen A; Alsabeeha, Nabeel; Duncan, Warwick J

    2018-05-15

    Clinical trials have suggested that dental implants with a tapered configuration have improved stability at placement, allowing immediate placement and/or loading. The aim of this systematic review and meta-analysis was to evaluate the implant stability of tapered dental implants compared to standard parallel-walled dental implants. Applying the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement, randomized controlled trials (RCTs) were searched for in electronic databases and complemented by hand searching. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool and data were analyzed using statistical software. A total of 1199 studies were identified, of which, five trials were included with 336 dental implants in 303 participants. Overall meta-analysis showed that tapered dental implants had higher implant stability values than parallel-walled dental implants at insertion and 8 weeks but the difference was not statistically significant. Tapered dental implants had significantly less marginal bone loss compared to parallel-walled dental implants. No significant differences in implant failure rate were found between tapered and parallel-walled dental implants. There is limited evidence to demonstrate the effectiveness of tapered dental implants in achieving greater implant stability compared to parallel-walled dental implants. Superior short-term results in maintaining peri-implant marginal bone with tapered dental implants are possible. Further properly designed RCTs are required to endorse the supposed advantages of tapered dental implants in immediate loading protocol and other complex clinical scenarios. © 2018 Wiley Periodicals, Inc.

  4. Influence of immediate loading on provisional restoration in dental implant stability

    Science.gov (United States)

    Ikbal, M.; Odang, R. W.; Indrasari, M.; Dewi, R. S.

    2017-08-01

    The success of dental implant treatment is determined by the primary stability at placement. One factor that could influence this stability is occlusal loading through provisional restoration. Two types of loading protocols are usually used: immediate and delayed loading. However, some controversies remain about the influence of occlusal loading on implant stability. Therefore, the influence of immediate loading on implant stability must be studied. An animal study was conducted by placing nine dental implants in the mandibular jaw of three Macaca fascicularis. Provisional restorations with various occlusal contacts (no, light, and normal contact) were placed on the implant. The implant stability was measured using the Ostell ISQ three times: immediately (baseline) and at the first and second months after implant placement. The implant stability between implants with no and normal occlusal contact as well as light and normal occlusal contact showed significant differences (p implant placement. However, no significant increase (p > 0.05) in implant stability was seen at the baseline and the first and second months after implant placement for all occlusal contact groups. Immediate loading influenced the implant stability, and provisional restoration of implant without occlusal contact showed the highest implant stability.

  5. Immediately loaded mini dental implants as overdenture retainers: 1-Year cohort study of implant stability and peri-implant marginal bone level.

    Science.gov (United States)

    Šćepanović, Miodrag; Todorović, Aleksandar; Marković, Aleksa; Patrnogić, Vesna; Miličić, Biljana; Moufti, Adel M; Mišić, Tijana

    2015-05-01

    This 1-year cohort study investigated stability and peri-implant marginal bone level of immediately loaded mini dental implants used to retain overdentures. Each of 30 edentulous patients received 4 mini dental implants (1.8 mm × 13 mm) in the interforaminal mandibular region. The implants were immediately loaded with pre-made overdentures. Outcome measures included implant stability and bone resorption. Implant stability was measured using the Periotest Classic(®) device immediately after placement and on the 3rd and 6th weeks and the 4th, 6th and 12th months postoperatively. The peri-implant marginal bone level (PIBL) was evaluated at the implant's mesial and distal sides from the polished platform to the marginal crest. Radiographs were taken using a tailored film holder to reproducibly position the X-ray tube at the 6th week, 4th and 12th months postoperatively. The primary stability (Periotest value, PTV) measured -0.27 ± 3.41 on a scale of -8 to + 50 (lower PTV reflects higher stability). The secondary stability decreased significantly until week 6 (mean PTV = 7.61 ± 7.05) then increased significantly reaching (PTV = 6.17 ± 6.15) at 12 months. The mean PIBL measured -0.40 mm after 1 year of functional loading, with no statistically significant differences at the various follow-ups (p = 0.218). Mini dental implants placed into the interforaminal region could achieve a favorable primary stability for immediate loading. The follow-up Periotest values fluctuated, apparently reflecting the dynamics of bone remodeling, with the implants remaining clinically stable (98.3%) after 1 year of function. The 1-year bone resorption around immediately loaded MDIs is within the clinically acceptable range for standard implants. Copyright © 2014 Elsevier GmbH. All rights reserved.

  6. Assessment of dental implant stability by means of the electromechanical impedance method

    International Nuclear Information System (INIS)

    Boemio, Giovanni; Rizzo, Piervincenzo; Nardo, Luigi De

    2011-01-01

    Implant stability is a prerequisite for functional recovery in load-bearing prostheses. Robust, reliable and noninvasive methods to assess the bone interface of dental and orthopedic implants are increasingly demanded for clinical diagnosis and direct prognosis. In this paper, a study of the feasibility of a noninvasive method based on electromechanical impedance (EMI) to assess dental prostheses stability is presented. Two different dental screws were entrenched in polyurethane foams (Sawbones ® ) and immersed in a solution of nitric acid to allow material degradation, inversely simulating a bone healing process. This process was monitored by bonding a piezoceramic transducer (PZT) to the implant and measuring the admittance of the PZT over time. It was found that the PZT's conductance and the statistical features associated with its analysis were sensitive to the degradation of the foams and can be correlated to the Sawbones mechanical properties. The present study shows promising results and may pave the road towards an innovative approach for the noninvasive monitoring of implanted prostheses

  7. Measurement of Primary and Secondary Stability of Dental Implants by Resonance Frequency Analysis Method in Mandible

    Science.gov (United States)

    Shokri, Mehran; Daraeighadikolaei, Arash

    2013-01-01

    Background. There is no doubt that the success of the dental implants depends on the stability. The aim of this work was to measure the stability of dental implants prior to loading the implants, using a resonance frequency analysis (RFA) by Osstell mentor device. Methods. Ten healthy and nonsmoker patients over 40 years of age with at least six months of complete or partial edentulous mouth received screw-type dental implants by a 1-stage procedure. RFA measurements were obtained at surgery and 1, 2, 3, 4, 5, 7, and 11 weeks after the implant surgery. Results. Among fifteen implants, the lowest mean stability measurement was for the 4th week after surgery in all bone types. At placement, the mean ISQ obtained with the magnetic device was 77.2 with 95% confidence interval (CI) = 2.49, and then it decreased until the 4th week to 72.13 (95% CI = 2.88), and at the last measurement, the mean implant stability significantly (P value implant placement. These suggestions need to be further assessed through future studies. PMID:23737790

  8. Does the Implant Surgical Technique Affect the Primary and/or Secondary Stability of Dental Implants? A Systematic Review

    Science.gov (United States)

    Shadid, Rola Muhammed; Sadaqah, Nasrin Rushdi; Othman, Sahar Abdo

    2014-01-01

    Background. A number of surgical techniques for implant site preparation have been advocated to enhance the implant of primary and secondary stability. However, there is insufficient scientific evidence to support the association between the surgical technique and implant stability. Purpose. This review aimed to investigate the influence of different surgical techniques including the undersized drilling, the osteotome, the piezosurgery, the flapless procedure, and the bone stimulation by low-level laser therapy on the primary and/or secondary stability of dental implants. Materials and methods. A search of PubMed, Cochrane Library, and grey literature was performed. The inclusion criteria comprised observational clinical studies and randomized controlled trials (RCTs) conducted in patients who received dental implants for rehabilitation, studies that evaluated the association between the surgical technique and the implant primary and/or secondary stability. The articles selected were carefully read and classified as low, moderate, and high methodological quality and data of interest were tabulated. Results. Eight clinical studies were included then they were classified as moderate or high methodological quality and control of bias. Conclusions. There is a weak evidence suggesting that any of previously mentioned surgical techniques could influence the primary and/or secondary implant stability. PMID:25126094

  9. Does the Implant Surgical Technique Affect the Primary and/or Secondary Stability of Dental Implants? A Systematic Review

    Directory of Open Access Journals (Sweden)

    Rola Muhammed Shadid

    2014-01-01

    Full Text Available Background. A number of surgical techniques for implant site preparation have been advocated to enhance the implant of primary and secondary stability. However, there is insufficient scientific evidence to support the association between the surgical technique and implant stability. Purpose. This review aimed to investigate the influence of different surgical techniques including the undersized drilling, the osteotome, the piezosurgery, the flapless procedure, and the bone stimulation by low-level laser therapy on the primary and/or secondary stability of dental implants. Materials and methods. A search of PubMed, Cochrane Library, and grey literature was performed. The inclusion criteria comprised observational clinical studies and randomized controlled trials (RCTs conducted in patients who received dental implants for rehabilitation, studies that evaluated the association between the surgical technique and the implant primary and/or secondary stability. The articles selected were carefully read and classified as low, moderate, and high methodological quality and data of interest were tabulated. Results. Eight clinical studies were included then they were classified as moderate or high methodological quality and control of bias. Conclusions. There is a weak evidence suggesting that any of previously mentioned surgical techniques could influence the primary and/or secondary implant stability.

  10. Correlation between radiographic analysis of alveolar bone density around dental implant and resonance frequency of dental implant

    Science.gov (United States)

    Prawoko, S. S.; Nelwan, L. C.; Odang, R. W.; Kusdhany, L. S.

    2017-08-01

    The histomorphometric test is the gold standard for dental implant stability quantification; however, it is invasive, and therefore, it is inapplicable to clinical patients. Consequently, accurate and objective alternative methods are required. Resonance frequency analysis (RFA) and digital radiographic analysis are noninvasive methods with excellent objectivity and reproducibility. To analyze the correlation between the radiographic analysis of alveolar bone density around a dental implant and the resonance frequency of the dental implant. Digital radiographic images for 35 samples were obtained, and the resonance frequency of the dental implant was acquired using Osstell ISQ immediately after dental implant placement and on third-month follow-up. The alveolar bone density around the dental implant was subsequently analyzed using SIDEXIS-XG software. No significant correlation was reported between the alveolar bone density around the dental implant and the resonance frequency of the dental implant (r = -0.102 at baseline, r = 0.146 at follow-up, p > 0.05). However, the alveolar bone density and resonance frequency showed a significant difference throughout the healing period (p = 0.005 and p = 0.000, respectively). Conclusion: Digital dental radiographs and Osstell ISQ showed excellent objectivity and reproducibility in quantifying dental implant stability. Nonetheless, no significant correlation was observed between the results obtained using these two methods.

  11. Stability of dental implants in grafted bone in the anterior maxilla: longitudinal study.

    LENUS (Irish Health Repository)

    Al-Khaldi, Nasser

    2010-06-06

    We aimed to assess the stability over time of dental implants placed in grafted bone in the maxilla using resonance frequency analysis, and to compare the stability of implants placed in grafted and non-grafted bone. Data were collected from 23 patients (15 test and 8 controls) in whom 64 implants (Brånemark system, Nobel Biocare, Göteborg, Sweden) were placed in accordance with the two-stage surgical protocol. In the test group 36 fixtures were placed in grafted bone, and in the control group 28 fixtures were placed in non-grafted bone. Resonance frequency analysis was used to assess the test sites at implant placement and abutment connection. The mean (SD) implant stability quotient (ISQ) for test sites at the time of implant placement was 61.91 (6.68), indicating excellent primary stability, and was 63.53 (5.76) at abutment connection. ISQ values at abutment connection were similar for test and control sites. Implants placed in grafted bone compared favourably with those in non-grafted bone, and showed excellent stability.

  12. Low-level laser therapy with 940 nm diode laser on stability of dental implants: a randomized controlled clinical trial.

    Science.gov (United States)

    Torkzaban, Parviz; Kasraei, Shahin; Torabi, Sara; Farhadian, Maryam

    2018-02-01

    Low-level laser therapy (LLLT) is a non-invasive modality to promote osteoblastic activity and tissue healing. The aim of this study was to evaluate the efficacy of LLLT for improvement of dental implant stability. This randomized controlled clinical trial was performed on 80 dental implants placed in 19 patients. Implants were randomly divided into two groups (n = 40). Seven sessions of LLLT (940 nm diode laser) were scheduled for the test group implants during 2 weeks. Laser was irradiated to the buccal and palatal sides. The same procedure was performed for the control group implants with laser hand piece in "off" mode. Implant stability was measured by Osstell Mentor device in implant stability quotient (ISQ) value immediately after surgery and 10 days and 3, 6, and 12 weeks later. Repeated measures ANOVA was used to compare the mean ISQ values (implant stability) in the test and control groups. Statistical test revealed no significant difference in the mean values of implant stability between the test and control groups over time (P = 0.557). Although the mean values of implant stability changed significantly in both groups over time (P laser group in the first weeks and increased from the 6th to 12th week, LLLT had no significant effect on dental implant stability.

  13. Mixed zirconia calcium phosphate coatings for dental implants: Tailoring coating stability and bioactivity potential

    International Nuclear Information System (INIS)

    Pardun, Karoline; Treccani, Laura; Volkmann, Eike; Streckbein, Philipp; Heiss, Christian; Destri, Giovanni Li; Marletta, Giovanni; Rezwan, Kurosch

    2015-01-01

    Enhanced coating stability and adhesion are essential for long-term success of orthopedic and dental implants. In this study, the effect of coating composition on mechanical, physico-chemical and biological properties of coated zirconia specimens is investigated. Zirconia discs and dental screw implants are coated using the wet powder spraying (WPS) technique. The coatings are obtained by mixing yttria-stabilized zirconia (TZ) and hydroxyapatite (HA) in various ratios while a pure HA coating served as reference material. Scanning electron microscopy (SEM) and optical profilometer analysis confirm a similar coating morphology and roughness for all studied coatings, whereas the coating stability can be tailored with composition and is probed by insertion and dissections experiments in bovine bone with coated zirconia screw implants. An increasing content of calcium phosphate (CP) resulted in a decrease of mechanical and chemical stability, while the bioactivity increased in simulated body fluid (SBF). In vitro experiments with human osteoblast cells (HOB) revealed that the cells grew well on all samples but are affected by dissolution behavior of the studied coatings. This work demonstrates the overall good mechanical strength, the excellent interfacial bonding and the bioactivity potential of coatings with higher TZ contents, which provide a highly interesting coating for dental implants. - Highlights: • Different ratios of zirconia (TZ) and calcium phosphate (CP) were deposited on zirconia substrates. • Enhancement of TZ content in mixed coatings increased coating stability. • Enhancement of CP content in mixed coatings increased bioactivity. • All tested coating compositions were non-toxic

  14. Mixed zirconia calcium phosphate coatings for dental implants: Tailoring coating stability and bioactivity potential

    Energy Technology Data Exchange (ETDEWEB)

    Pardun, Karoline [University of Bremen, Advanced Ceramics, Am Biologischen Garten 2, 28359 Bremen (Germany); Treccani, Laura, E-mail: treccani@uni-bremen.de [University of Bremen, Advanced Ceramics, Am Biologischen Garten 2, 28359 Bremen (Germany); Volkmann, Eike [University of Bremen, Advanced Ceramics, Am Biologischen Garten 2, 28359 Bremen (Germany); Streckbein, Philipp [University Hospital, Justus-Liebig-University Giessen, Department of Cranio-Maxillo-Facial Surgery, Klinikstrasse 33, 35385 Giessen (Germany); Heiss, Christian [University Hospital of Giessen-Marburg, Department of Trauma Surgery, Rudolf-Buchheim-Strasse 7, 35385 Giessen, Germany, (Germany); Laboratory of Experimental Surgery, Kerkraderstrasse 9, 35392 Giessen (Germany); Destri, Giovanni Li; Marletta, Giovanni [Laboratory for Molecular Surfaces and Nanotechnology (LAMSUN), Department of Chemistry, University of Catania and CSGI, Viale A. Doria 6, 95125 Catania (Italy); Rezwan, Kurosch [University of Bremen, Advanced Ceramics, Am Biologischen Garten 2, 28359 Bremen (Germany)

    2015-03-01

    Enhanced coating stability and adhesion are essential for long-term success of orthopedic and dental implants. In this study, the effect of coating composition on mechanical, physico-chemical and biological properties of coated zirconia specimens is investigated. Zirconia discs and dental screw implants are coated using the wet powder spraying (WPS) technique. The coatings are obtained by mixing yttria-stabilized zirconia (TZ) and hydroxyapatite (HA) in various ratios while a pure HA coating served as reference material. Scanning electron microscopy (SEM) and optical profilometer analysis confirm a similar coating morphology and roughness for all studied coatings, whereas the coating stability can be tailored with composition and is probed by insertion and dissections experiments in bovine bone with coated zirconia screw implants. An increasing content of calcium phosphate (CP) resulted in a decrease of mechanical and chemical stability, while the bioactivity increased in simulated body fluid (SBF). In vitro experiments with human osteoblast cells (HOB) revealed that the cells grew well on all samples but are affected by dissolution behavior of the studied coatings. This work demonstrates the overall good mechanical strength, the excellent interfacial bonding and the bioactivity potential of coatings with higher TZ contents, which provide a highly interesting coating for dental implants. - Highlights: • Different ratios of zirconia (TZ) and calcium phosphate (CP) were deposited on zirconia substrates. • Enhancement of TZ content in mixed coatings increased coating stability. • Enhancement of CP content in mixed coatings increased bioactivity. • All tested coating compositions were non-toxic.

  15. Implant stability and marginal bone level of microgrooved zirconia dental implants: A 3-month experimental study on dogs

    Directory of Open Access Journals (Sweden)

    Delgado-Ruíz Rafael Arcesio

    2014-01-01

    Full Text Available Background/Aim. The modification of implant surfaces could affect mechanical implant stability as well as dynamics and quality of peri-implant bone healing. The aim of this 3-month experimental study in dogs was to investigate implant stability, marginal bone levels and bone tissue response to zirconia dental implants with two laser-micro-grooved intraosseous surfaces in comparison with nongrooved sandblasted zirconia and sandblasted, high-temperature etched titanium implants. Methods. Implant surface characterization was performed using optical interferometric profilometry and energy dispersive X-ray spectroscopy. A total of 96 implants (4 mm in diameter and 10 mm in length were inserted randomly in both sides of the lower jaw of 12 Fox Hound dogs divided into groups of 24 each: the control (titanium, the group A (sandblasted zirconia, the group B (sandblasted zirconia plus microgrooved neck and the group C (sandblasted zirconia plus all microgrooved. All the implants were immediately loaded. Insertion torque, periotest values, radiographic crestal bone level and removal torque were recorded during the 3-month follow-up. Qualitative scanning electon micro-scope (SEM analysis of the bone-implant interfaces of each group was performed. Results. Insertion torque values were higher in the group C and control implants (p the control > the group B > the group A (p the control > the group B > the group A (p < 0.05. SEM showed that implant surfaces of the groups B and C had an extra bone growth inside the microgrooves that corresponded to the shape and direction of the microgrooves. Conclusion. The addition of micro-grooves to the entire intraosseous surface of zirconia dental implants enhances primary and secondary implant stability, promotes bone tissue ingrowth and preserves crestal bone levels.

  16. Dental implants in growing children

    Directory of Open Access Journals (Sweden)

    S K Mishra

    2013-01-01

    Full Text Available The replacement of teeth by implants is usually restricted to patients with completed craniofacial growth. The aim of this literature review is to discuss the use of dental implants in normal growing patients and in patients with ectodermal dysplasia and the influence of maxillary and mandibular skeletal and dental growth on the stability of those implants. It is recommended that while deciding the optimal individual time point of implant insertion, the status of skeletal growth, the degree of hypodontia, and extension of related psychological stress should be taken into account, in addition to the status of existing dentition and dental compliance of a pediatric patient.

  17. Nanohydroxyapatite Silicate-Based Cement Improves the Primary Stability of Dental Implants: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    Hooman Khorshidi

    2017-01-01

    Full Text Available Objectives. Insufficient cortical bone volume when placing implants can lead to lack of primary stability. The use of cement as a bone fill material in bone defects around dental implant could result in better clinical outcome. HA has shown excellent biological properties in implant dentistry. The purpose of this study was to evaluate the effect of nanohydroxyapatite powder (Nano-HA in combination with accelerated Portland cement (APC on implant primary stability in surgically created circumferential bone defects in a bovine rib in vitro model. Materials and Methods. Sixteen bovine rib bones and thirty-six implants of same type and size (4 mm × 10 mm were used. Implants were divided into six groups: no circumferential bone defect, defect and no grafting, bone chips grafting, Nano-HA grafting, APC grafting, and Nano-HA mixed to APC grafting (Nano-HA-APC. Circumferential defects around the implants were prepared. The implant stability quotient (ISQ values were measured before and after the grafting. Results. APC exhibited the highest ISQ values. A significant increase of ISQ values following the grafting of Nano-HA-APC (18.08±5.82 and APC alone (9.50±4.12 was achieved. Increase of ISQ values after 72 hours was 24.16±5.01 and 17.58±4.89, respectively. Nano-HA grafting alone exhibited the least rise in ISQ values. Conclusions. Nanohydroxyapatite silicate-based cement could improve the primary stability of dental implants in circumferential bone defect around implants.

  18. Predicting the dental implant stability based on the antiresonance phase of a piezo-based impedance sensor

    Directory of Open Access Journals (Sweden)

    Paramita Banerjee

    2017-01-01

    Full Text Available Background: The stability of dental implants (DIs in in vivo tests can be determined using noninvasive resonance frequency analysis technique. A low-cost piezo-based sensor has been developed for this purpose which uses a readily available two-terminal piezo element, to which a metal substrate is adhesively glued for attaching the implant. Aim: The attainment of implant stability in dynamic tests using this sensor must be standardized in terms of the major antiresonance (AR in the impedance phase responses using sensor-DI assembly. This will be used to predetermine the dimensions of the glued metal substrate in the sensor design. Materials and Methods: Multiple sensors with varying sensor dimensions were developed. Static and dynamic impedance studies were performed on these and corresponding sensor-implant assemblies. Static tests as well as in vitro tests with the sensor-implant assembly dipped in a standardized dental plaster mixture were performed in controlled laboratory conditions. Results: The probability of acceptance of the hypothesis has been checked using binomial distribution with a significance level of 5%. Statistically observed that for 95% of the cases where the DI becomes stable in dental plaster, both AR phase and AR frequency (ARF return to their corresponding static values. Furthermore, for a piezo element, whose ARF is within 6–6.6 kHz, the sensor yields maximal phase when the length of the metallic strip is 2 cm. Conclusions: Experimental validation supports both claims. Hence, this work can be extended to in vivo DI stability determination and design aspects of the corresponding sensor.

  19. Primary stability and self-tapping blades: biomechanical assessment of dental implants in medium-density bone.

    Science.gov (United States)

    Kim, Yung-Soo; Lim, Young-Jun

    2011-10-01

    The aim of this biomechanical study was to assess the influence of self-tapping blades in terms of primary implant stability between implants with self-tapping blades and implants without self-tapping blades using five different analytic methods, especially in medium-density bone. Two different types of dental implants (4 × 10 mm) were tested: self-tapping and non-self-tapping. The fixture design including thread profiles was exactly the same between the two groups; the only difference was the presence of cutting blades on one half of the apical portion of the implant body. Solid rigid polyurethane blocks with corresponding densities were selected to simulate medium-density bone. Five mechanical assessments (insertion torque, resonance frequency analysis [RFA], reverse torque, pull-out and push in test) were performed for primary stability. Implants without self-tapping blades showed significantly higher values (P0.05). The outcomes of the present study indicate that the implant body design without self-tapping blades has a good primary stability compared with that with self-tapping blades in medium-density bone. Considering the RFA, a distinct layer of cortical bone on marginal bone will yield implant stability quotient values similar to those in medium-bone density when implants have the same diameter. © 2011 John Wiley & Sons A/S.

  20. The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography

    Science.gov (United States)

    2016-01-01

    Purpose The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. Methods We measured the impact response of a dental implant placed into swine bone specimens composed of only trabecular bone without the cortical bone layer using an inductive sensor. The peak frequency of the impact response spectrum was determined as an implant stability criterion (SPF). The 3D microstructural parameters were calculated from CT images of the bone specimens obtained using both micro-CT and CBCT. Results SPF had significant positive correlations with trabecular bone structural parameters (BV/TV, BV, BS, BSD, Tb.Th, Tb.N, FD, and BS/BV) (Pmicro-CT and CBCT (Pimplant stability prediction by combining BV/TV and SMI in the stepwise forward regression analysis. Bone with high volume density and low surface density shows high implant stability. Well-connected thick bone with small marrow spaces also shows high implant stability. The combination of bone density and architectural parameters measured using CBCT can predict the implant stability more accurately than the density alone in clinical diagnoses. PMID:27127692

  1. CLINICAL CONSIDERATIONS OF DENTAL IMPLANT SYSTEM IN IMMEDIATE LOADING IMPLANT CASES

    Directory of Open Access Journals (Sweden)

    Carolina Damayanti Marpaung

    2015-06-01

    Full Text Available Immediate loading of dental implant has been researched intensively in the development of Branemark’s early concept of 2 stages implant placement. This was embarked from both patients and practiitioner’s convenience towards a simpler protocol and shorter time frame. Many recent researchers later found that micromotions derived from occlusal loading for a certain degree, instead of resulting a fibrous tissue encapsulation, can enhance the osseointegration process. Dental Implant system enhancement towards maximizing the primary stability held a key factor in Branemark’s concept development. Surgical protocol and implant design was found to give a significant contribution to the prognosis of immediate-loading implants.

  2. Occlusal considerations for dental implant restorations.

    Science.gov (United States)

    Bergmann, Ranier H

    2014-01-01

    When placed, dental implants are put into an ever-changing oral environment in which teeth can continue to migrate. Yet, the implants themselves are ankylosed. This can lead to occlusal instability. Teeth may continue to erupt, leaving the implants in infraocclusion. Teeth may move mesially away from an implant, requiring modification to close an open contact point. Friction in the connection between teeth and implants can lead to intrusion of teeth and damage to the periodontal attachment apparatus. Implant occlusion with shallow incisal guidance minimizes lateral and tipping forces. Cross-arch stabilization allows the best distribution of occlusal forces. The choice of restorative materials influences long-term occlusal stability.

  3. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  4. Evaluating mechanical properties and degradation of YTZP dental implants

    International Nuclear Information System (INIS)

    Sevilla, Pablo; Sandino, Clara; Arciniegas, Milena; Martinez-Gomis, Jordi; Peraire, Maria; Gil, Francisco Javier

    2010-01-01

    Lately new biomedical grade yttria stabilized zirconia (YTZP) dental implants have appeared in the implantology market. This material has better aesthetical properties than conventional titanium used for implants but long term behaviour of these new implants is not yet well known. The aim of this paper is to quantify the mechanical response of YTZP dental implants previously degraded under different time conditions and compare the toughness and fatigue strength with titanium implants. Mechanical response has been studied by means of mechanical testing following the ISO 14801 for Standards for dental implants and by finite element analysis. Accelerated hydrothermal degradation has been achieved by means of water vapour and studied by X-ray diffraction and nanoindentation tests. The results show that the degradation suffered by YTZP dental implants will not have a significant effect on the mechanical behaviour. Otherwise the fracture toughness of YTZP ceramics is still insufficient in certain implantation conditions.

  5. Finite element analysis (FEA) of dental implant fixture for mechanical stability and rapid osseointegration

    Science.gov (United States)

    Tabassum, Shafia; Murtaza, Ahmar; Ali, Hasan; Uddin, Zia Mohy; Zehra, Syedah Sadaf

    2017-10-01

    For rapid osseointegration of dental implant fixtures, various surface treatments including plasma spraying, hydroxyapatite coating, acid-etching, and surface grooving are used. However undesirable effects such as chemical modifications, loss of mechanical properties, prolonged processing times and post production treatment steps are often associated with these techniques. The osseointegration rate of the dental implants can be promoted by increasing the surface area of the dental implant, thus increasing the bone cells - implant material contact and allow bone tissues to grow rapidly. Additive Manufacturing (AM) techniques can be used to fabricate dental implant fixtures with desirable surface area in a single step manufacturing process. AM allows the use of Computer Aided Designing (CAD) for customised rapid prototyping of components with precise control over geometry. In this study, the dental implant fixture that replaces the tooth root was designed on commercially available software COMSOL. Nickel - titanium alloy was selected as build materials for dental implant. The geometry of the dental fixture was varied by changing the interspacing distance (thread pitch) and number of threads to increase the total surface area. Three different microstructures were introduced on the surface of dental implant. The designed models were used to examine the effect of changing geometries on the total surface area. Finite Element Analysis (FEA) was performed to investigate the effect of changing geometries on the mechanical properties of the dental implant fixtures using stress analysis.

  6. Effects of the 3D bone-to-implant contact and bone stiffness on the initial stability of a dental implant: micro-CT and resonance frequency analyses.

    Science.gov (United States)

    Hsu, J T; Huang, H L; Tsai, M T; Wu, A Y J; Tu, M G; Fuh, L J

    2013-02-01

    This study investigated the effects of bone stiffness (elastic modulus) and three-dimensional (3D) bone-to-implant contact ratio (BIC%) on the primary stabilities of dental implants using micro-computed tomography (micro-CT) and resonance frequency analyses. Artificial sawbone models with five values of elastic modulus (137, 123, 47.5, 22, and 12.4 MPa) comprising two types of trabecular structure (solid-rigid and cellular-rigid) were investigated for initial implant stability quotient (ISQ), measured using the wireless Osstell resonance frequency analyzer. Bone specimens were attached to 2 mm fibre-filled epoxy sheets mimicking the cortical shell. ISQ was measured after placing a dental implant into the bone specimen. Each bone specimen with an implant was subjected to micro-CT scanning to calculate the 3D BIC% values. The similarity of the cellular type of artificial bone to the trabecular structure might make it more appropriate for obtaining accurate values of primary implant stability than solid-bone blocks. For the cellular-rigid bone models, the ISQ increased with the elastic modulus of cancellous bone. The regression correlation coefficient was 0.96 for correlations of the ISQ with the elasticity of cancellous bone and with the 3D BIC%. The initial implant stability was moderately positively correlated with the elasticity of cancellous bone and with the 3D BIC%. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Surface degradation of nanocrystalline zirconia dental implants

    NARCIS (Netherlands)

    Ocelík, Václav; Schepke, Ulf; Rasoul, Hamid Haji; Cune, Marco S.; De Hosson, Jeff Th M.

    2017-01-01

    Yttria-stabilized zirconia prepared by hot isostatic pressing represents attractive material for biomedical applications. In this work the degradation of yttria-stabilized zirconia dental implants abutments due to the tetragonal to monoclinic phase transformation after one year of clinical use was

  8. The medically compromised patient: Are dental implants a feasible option?

    Science.gov (United States)

    Vissink, A; Spijkervet, Fkl; Raghoebar, G M

    2018-03-01

    In healthy subjects, dental implants have evolved to be a common therapy to solve problems related to stability and retention of dentures as well as to replace failing teeth. Although dental implants are applied in medically compromised patients, it is often not well known whether this therapy is also feasible in these patients, whether the risk of implant failure and developing peri-implantitis is increased, and what specific preventive measures, if any, have to be taken when applying dental implants in these patients. Generally speaking, as was the conclusion by the leading review of Diz, Scully, and Sanz on placement of dental implants in medically compromised patients (J Dent, 41, 2013, 195), in a few disorders implant survival may be lower, and the risk of a compromised peri-implant health and its related complications be greater, but the degree of systemic disease control outweighs the nature of the disorder rather than the risk accompanying dental implant treatment. So, as dental implant treatment is accompanied by significant functional benefits and improved oral health-related quality of life, dental implant therapy is a feasible treatment in almost any medically compromised patient when the required preventive measures are taken and follow-up care is at a high level. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd. All rights reserved.

  9. Automated dental implantation using image-guided robotics: registration results.

    Science.gov (United States)

    Sun, Xiaoyan; McKenzie, Frederic D; Bawab, Sebastian; Li, Jiang; Yoon, Yongki; Huang, Jen-K

    2011-09-01

    One of the most important factors affecting the outcome of dental implantation is the accurate insertion of the implant into the patient's jaw bone, which requires a high degree of anatomical accuracy. With the accuracy and stability of robots, image-guided robotics is expected to provide more reliable and successful outcomes for dental implantation. Here, we proposed the use of a robot for drilling the implant site in preparation for the insertion of the implant. An image-guided robotic system for automated dental implantation is described in this paper. Patient-specific 3D models are reconstructed from preoperative Cone-beam CT images, and implantation planning is performed with these virtual models. A two-step registration procedure is applied to transform the preoperative plan of the implant insertion into intra-operative operations of the robot with the help of a Coordinate Measurement Machine (CMM). Experiments are carried out with a phantom that is generated from the patient-specific 3D model. Fiducial Registration Error (FRE) and Target Registration Error (TRE) values are calculated to evaluate the accuracy of the registration procedure. FRE values are less than 0.30 mm. Final TRE values after the two-step registration are 1.42 ± 0.70 mm (N = 5). The registration results of an automated dental implantation system using image-guided robotics are reported in this paper. Phantom experiments show that the practice of robot in the dental implantation is feasible and the system accuracy is comparable to other similar systems for dental implantation.

  10. Immediate versus delayed loading of strategic mini dental implants for the stabilization of partial removable dental prostheses: a patient cluster randomized, parallel-group 3-year trial.

    Science.gov (United States)

    Mundt, Torsten; Al Jaghsi, Ahmad; Schwahn, Bernd; Hilgert, Janina; Lucas, Christian; Biffar, Reiner; Schwahn, Christian; Heinemann, Friedhelm

    2016-07-30

    Acceptable short-term survival rates (>90 %) of mini-implants (diameter implants as strategic abutments for a better retention of partial removable dental prosthesis (PRDP) are not available. The purpose of this study is to test the hypothesis that immediately loaded mini-implants show more bone loss and less success than strategic mini-implants with delayed loading. In this four-center (one university hospital, three dental practices in Germany), parallel-group, controlled clinical trial, which is cluster randomized on patient level, a total of 80 partially edentulous patients with unfavourable number and distribution of remaining abutment teeth in at least one jaw will receive supplementary min-implants to stabilize their PRDP. The mini-implant are either immediately loaded after implant placement (test group) or delayed after four months (control group). Follow-up of the patients will be performed for 36 months. The primary outcome is the radiographic bone level changes at implants. The secondary outcome is the implant success as a composite variable. Tertiary outcomes include clinical, subjective (quality of life, satisfaction, chewing ability) and dental or technical complications. Strategic implants under an existing PRDP are only documented for standard-diameter implants. Mini-implants could be a minimal invasive and low cost solution for this treatment modality. The trial is registered at Deutsches Register Klinischer Studien (German register of clinical trials) under DRKS-ID: DRKS00007589 ( www.germanctr.de ) on January 13(th), 2015.

  11. The Key Points of Maintenance Therapy for Dental Implants: A Literature Review.

    Science.gov (United States)

    Pirc, Miha; Dragan, Irina F

    2017-04-01

    Dental implants require lifelong maintenance and care. Success is defined by biologic factors (presence of inflamed soft tissues surrounding dental implants and radiographic changes in the crestal bone levels) and mechanical factors (stability of the implant fixture and implant supported restoration, etc). Most implant failures are initiated by incipient stages of inflammatory processes, which lead to peri-mucositis and peri-implantitis. The evidence regarding the value of maintenance protocol regarding implants is sparse compared with the one for teeth. This article addresses the existing literature on processes for oral hygiene for implant care.

  12. Clinical and radiological investigations of mandibular overdentures supported by conventional or mini-dental implants: A 2-year prospective follow-up study.

    Science.gov (United States)

    Temizel, Sonay; Heinemann, Friedhelm; Dirk, Cornelius; Bourauel, Christoph; Hasan, Istabrak

    2017-02-01

    Conventional dental implants are not applicable in the mandibular interforaminal region if bone volume is limited. Mini-dental implants offer an alternative means of supporting mandibular overdentures in a narrow residual ridge, without additional surgery. The purpose of this nonrandomized clinical trial was to compare the ability of mini-dental implants with that of conventional dental implants in supporting mandibular overdentures during a 2-year clinical follow-up. Bone quality, bone resorption, implant stability, and oral health were assessed radiographically. A total of 32 participants with edentulism were included. Twenty-two participants (99 implants) received 4 to 5 mini-dental implants (diameter: 1.8-2.4 mm; length: 13-15 mm, study group), and 10 participants (35 implants) received 2 to 4 conventional dental implants (diameter: 3.3-3.7 mm; length: 11-13 mm, control group). The selection of the participants in the study or control group was based on the available bone volume in the mandible. The selection was not randomized. The density of cortical bone thickness was measured in Hounsfield units (HU) from computed tomography data, and patients were followed for 2 years. The participants were examined 3, 6, 12, and 24 months after surgery. Primary stability immediately after the insertion of dental implants (Periotest), secondary stability 6 months after implantation, modified plaque, bleeding on probing indices, and probing depth were measured and analyzed statistically (α=.05). The mean HU value 6 months after implantation in the participants who received mini-dental implants was significantly (P=.035) higher (1250 HU) than that in the participants who received conventional dental implants (1100 HU). The probing depths around the conventional dental implants (1.6 and 1.8 mm, respectively) were significantly higher than those around the mini-dental implants (1.3 and 1.2 mm, respectively) 12 and 24 months after surgery, respectively (Pdental implants were

  13. R&D on dental implants breakage

    Science.gov (United States)

    Croitoru, Sorin Mihai; Popovici, Ion Alexandru

    2017-09-01

    Most used dental implants for human dental prostheses are of two steps type: first step means implantation and, after several months healing and osseointegration, second step is prosthesis fixture. For sure, dental implants and prostheses are meant to last for a lifetime. Still, there are unfortunate cases when dental implants break. This paper studies two steps dental implants breakage and proposes a set of instruments for replacement and restoration of the broken implant. First part of the paper sets the input data of the study: structure of the studied two steps dental implants based on two Romanian patents and values of the loading forces found in practice and specialty papers. In the second part of the paper, using DEFORM 2D™ FEM simulation software, worst case scenarios of loading dental implants are studied in order to determine which zones and components of the dental implant set are affected (broken). Last part of the paper is dedicated to design and presentation of a set for extracting and cutting tools used to restore the broken implant set.

  14. Progressive immediate loading of a perforated maxillary sinus dental implant: a case report

    Directory of Open Access Journals (Sweden)

    Al-Juboori MJ

    2015-01-01

    Full Text Available Mohammed Jasim Al-Juboori Department of Oral Surgery, MAHSA University, Kuala Lumpur, Malaysia Abstract: The displacement of a dental implant into the maxillary sinus may lead to implant failure due to exposure of the apical third or the tip of the implant beyond the bone, resulting in soft tissue growth. This case report discusses dental implant placement in the upper first molar area with maxillary sinus involvement of approximately 2 mm. A new technique for progressive implant loading was used, involving immediately loaded implants with maxillary sinus perforation and low primary stability. Follow-up was performed with resonance frequency analysis and compared with an implant placed adjacent in the upper second premolar area using a conventional delayed loading protocol. Implants with maxillary sinus involvement showed increasing stability during the healing period. We found that progressive implant loading may be a safe technique for the placement of immediately loaded implants with maxillary sinus involvement. Keywords: progressive implant loading, resonance frequency analysis, implant stability, provisional crown, bone density, maxillary sinus

  15. Dental implants for severely atrophied jaws due to ectodermal dysplasia

    Directory of Open Access Journals (Sweden)

    Preetha Balaji

    2015-01-01

    Full Text Available The aim was to present the successful esthetical and functional rehabilitation of partial anodontia in a case of severe ectodermal dysplasia with complete atrophy of the jaws. A 17-year-old male with Class III malocclusion with partial anodontia sought dental implant treatment. His expectation was that of Class I occlusion. The challenge in the case was to match the expectation, reality, and the clinical possibilities. Ridge augmentation was performed with a combination of rib graft and recombinant human bone morphogenetic protein-2. Simultaneously, 6 implants (Nobel Biocare™ - Tapered Groovy were placed in maxillary arch and 10 in the mandible. Simultaneous placement ensured faster and better osseointegration though a mild compromise of the primary stability was observed initially. After adequate healing, Customized Zirconia Procera™ system was used to build the framework. Zirconia crown was cemented to the framework. Radiological and clinical evidence of osseointegration was observed in all 16 dental implants. Successful conversion of Class III to Class I occlusion was achieved with the combination of preprosthetic alveolar ridge augmentation, Procera™ Implant Bridge system. Abnormal angulations and or placement of dental implants would result in failure of the implant. Hence conversion of Class III to Class I occlusion needs complete and complex treatment planning so that the entire masticatory apparatus is sufficiently remodeled. Planning should consider the resultant vectors that would otherwise result in failure of framework or compromise the secondary stability of the dental implant during function. A successful case of rehabilitation of complex partial anodontia is presented.

  16. [Maintenance care for dental implant].

    Science.gov (United States)

    Kamoi, K

    1989-10-01

    Dental implant has tried at the early stage in 19th century recovering an oral function and esthetics. Technological revolutions in biochemical and new materials have developed on the remarkable change in the dental implants, nowadays we call the three generation therapy for dental implantology. There are many kinds of methods and techniques in dental implants, however a lot of troublesome complication on the process of surgical phase, construction of prothodontics and prognosis of maintenance care. In the proceedings of this symposium, I would like to propose you how to manage the maintenance care for various kind of dental implants through the methodology and case presentations. Tendenay and future for dental implants The current outlook of dental implant has increasing supply and demand not only dentists but also patients. According to Japanese Welfare Ministry's report in 1987, average missing teeth over sixty years old generations are approximately 42% in accordance with NIDR (U.S.A.) research. They are missed on ten over teeth in full 28th teeth dentitions owing to dental caries and periodontal diseases. Generally speaking, latent implant patients are occupied on the same possibility of needs for dental implants both Japan and U.S.A. Management of maintenance care The patients hardly recognized the importance of plaque control for the maintenance care in the intraoral condition after implantation. Dentists and dental staffs must be instruct patients for importance of plaque removal and control, because they already had forgotten the habit of teeth cleaning, especially in the edenturous conditions. 1) Concept of establishment in oral hygiene. Motivation and instruction for patients include very important factors in dental implants as well as in periodontal diseases. Patients who could not achieve on good oral hygiene levels obtained no good results in the long term observations. To establish good oral hygiene are how to control supra plaque surrounding tissues

  17. Comparative Clinical Study of Conventional Dental Implants and Mini Dental Implants for Mandibular Overdentures: A Randomized Clinical Trial.

    Science.gov (United States)

    Aunmeungtong, Weerapan; Kumchai, Thongnard; Strietzel, Frank P; Reichart, Peter A; Khongkhunthian, Pathawee

    2017-04-01

    Dental implant-retained overdentures have been chosen as the treatment of choice for complete mandibular removable dentures. Dental implants, such as mini dental implants, and components for retaining overdentures, are commercially available. However, comparative clinical studies comparing mini dental implants and conventional dental implants using different attachment for implant-retained overdentures have not been well documented. To compare the clinical outcomes of using two mini dental implants with Equator ® attachments, four mini dental implants with Equator attachments, or two conventional dental implants with ball attachments, by means of a randomized clinical trial. Sixty patients received implant-retained mandibular overdentures in the interforaminal region. The patients were divided into three groups. In Groups 1 and 2, two and four mini dental implants, respectively, were placed and immediately loaded by overdentures, using Equator ® attachments. In Group 3, conventional implants were placed. After osseointegration, the implants were loaded by overdentures, using ball attachments. The study distribution was randomized and double-blinded. Outcome measures included changes in radiological peri-implant bone level from surgery to 12 months postinsertion, prosthodontic complications and patient satisfaction. The cumulative survival rate in the three clinical groups after one year was 100%. There was no significant difference (p < 0.05) in clinical results regarding the number (two or four) of mini dental implants with Equator attachments. However, there was a significant difference in marginal bone loss and patient satisfaction between those receiving mini dental implants with Equator attachments and conventional dental implants with ball attachments. The marginal bone resorption in Group 3 was significantly higher than in Groups 1 and 2 (p < 0.05); there were no significant differences between Groups 1 and 2. There was no significant difference in

  18. Optimization of dental implantation

    Science.gov (United States)

    Dol, Aleksandr V.; Ivanov, Dmitriy V.

    2017-02-01

    Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.

  19. Comprehensive rehabilitation using dental implants in generalized aggressive periodontitis

    Directory of Open Access Journals (Sweden)

    Asha Ramesh

    2017-01-01

    Full Text Available Generalized aggressive periodontitis (GAP is a debilitating form of the disease and it results in deteriorating effects on the esthetic and functional aspects of the oral cavity. This case report describes the comprehensive rehabilitation of GAP patient using dental implants. The treatment planning involved thorough scaling and root planning (SRP with oral hygiene instructions. The patient was motivated to adhere to a strict oral hygiene regimen following which periodontal flap surgery employing guided tissue regeneration and bone grafts was performed. Bacterial culture for anaerobic microorganisms was done using a gas pack pre- and postperiodontal treatment to confirm the effectiveness of the periodontal treatment regimen and also to proceed with dental implant placement. The rigorous maintenance program ensured the stability of the periodontium following which immediate placement of dental implants in the maxillary and mandibular anterior region was done. The fixed metal-ceramic prosthesis was fabricated in a step-by-step process and the patient was recalled on a periodic basis over a 3-year follow-up duration. This case is a testimonial to the postperiodontal treatment long-term stability with excellent patient cooperation and strict maintenance protocol.

  20. Awareness of dental implants among dental patients in Nigeria ...

    African Journals Online (AJOL)

    The aim of this study was to determine the level of awareness of dental implant in Nigerian patients and their willingness to choose dental implant as a tooth replacement option. A survey was conducted among patients presenting for dental treatment in 3 teaching hospitals and private dental clinics in 3 urban cities of ...

  1. From acid etching treatments to tribocorrosive properties of dental implants: do some experimental results on surface treatments have an influence on the tribocorrosion behaviour of dental implants?

    International Nuclear Information System (INIS)

    Geringer, Jean; Demanget, Nicolas; Pellier, Julie

    2013-01-01

    Surface treatments of dental implants aim at promoting osseointegration, i.e. the anchorage of the metallic part. Titanium-, grade II–V, based material is used as a bulk material for dental implants. For promoting the anchorage of this metallic biomaterial in human jaw, some strategies have been applied for improving the surface state, i.e. roughness, topography and coatings. A case study, experimental study, is described with the method of acid etching on titanium grade 4, CpTi. The main goal is to find the right proportion in a mixture of two acids in order to obtain the best surface state. Finally, a pure theoretical prediction is quite impossible and some experimental investigations are necessary to improve the surface state. The described acid etching is compared with some other acid etching treatments and some coatings available on dental implants. Thus, the discussion is focused on the tribocorrosion behaviour of titanium-based materials. The purpose of the coating is that the lifetime under tribocorrosion is limited. Moreover, the surgery related to the implantation has a huge impact on the stability of dental implants. Thus, the performance of dental implants depends on factors related to surgery (implantation) that are difficult to predict from the biomaterial characteristics. From the tribocorrosion point of view, i.e. during the mastication step, the titanium material is submitted to some deleterious factors that cause the performance of dental implants to decrease. (paper)

  2. Clinical analysis of the stability of dental implants after preparation of the site by conventional drilling or piezosurgery.

    Science.gov (United States)

    da Silva Neto, Ulisses Tavares; Joly, Julio Cesar; Gehrke, Sergio Alexandre

    2014-02-01

    We used resonance frequency analysis to evaluate the implant stability quotient (ISQ) of dental implants that were installed in sites prepared by either conventional drilling or piezoelectric tips. We studied 30 patients with bilateral edentulous areas in the maxillary premolar region who were randomised to have the implant inserted with conventional drilling, or with piezoelectric surgery. The stability of each implant was measured by resonance frequency analysis immediately after placement to assess the immediate stability (time 1) and again at 90 days (time 2) and 150 days (time 3). In the conventional group the mean (SD) ISQ for time 1 was 69.1 (6.1) (95% CI 52.4-77.3); for time 2, 70.7 (5.7) (95% CI 60.4-82.8); and for time 3, 71.7 (4.5) (95% CI 64.2-79.2). In the piezosurgery group the corresponding values were: 77.5 (4.6) (95% CI 71.1-84.3) for time 1, 77.0 (4.2) (95% CI, 69.7-85.2) for time 2, and 79.1 (3.1) (95% CI 74.5-87.3) for time 3. The results showed significant increases in the ISQ values for the piezosurgery group at each time point (p=0.04). The stability of implants placed using the piezoelectric method was greater than that of implants placed using the conventional technique. Copyright © 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Revisiting the stability of mini-implants used for orthodontic anchorage

    Directory of Open Access Journals (Sweden)

    Chung-Chen Jane Yao

    2015-11-01

    Conclusion: This study revealed that once the dental surgeon becomes familiar with the procedure, the stability of orthodontic mini-implants depends on the type of mini-implant, age of the patient, implantation site, and the healing time of the mini-implant. Miniplates are a more feasible anchorage system when miniscrews fail repeatedly.

  4. 78 FR 2647 - Dental Devices; Reclassification of Blade-Form Endosseous Dental Implant

    Science.gov (United States)

    2013-01-14

    .... FDA-2012-N-0677] Dental Devices; Reclassification of Blade-Form Endosseous Dental Implant AGENCY: Food...) is proposing to reclassify the blade- form endosseous dental implant, a preamendments class III... proposing to revise the classification of blade-form endosseous dental implants. DATES: Submit either...

  5. Mecanobiología de la interfase hueso-implante dental Mechanobiology of bone-dental implant interphase

    Directory of Open Access Journals (Sweden)

    Juan Carlos Vanegas Acosta

    2010-03-01

    Full Text Available La osteointegración es la conexión estructural y funcional entre el hueso y un implante. Cuando un implante se inserta en el hueso, se crea la denominada interfase hueso-implante, una zona de unión entre la superficie del biomaterial del implante y el hueso circundante. La cicatrización de esta interfase depende de las condiciones biológicas del hueso, las características de diseño del implante y la distribución de cargas entre hueso e implante. En este artículo se hace una revisión del proceso de cicatrización de la interfase hueso-implante para el caso de un implante dental. El objetivo es describir la secuencia de eventos biológicos iniciados con la lesión causada por la inserción del implante y que concluyen con la formación de nuevo hueso en la interfase. Esta descripción incluye una novedosa clasificación de los fenómenos mecánicos que intervienen durante el proceso de cicatrización de los tejidos lesionados. Esta descripción mecanobiológica de la interfase hueso-implante dental se utiliza para determinar las características más relevantes a tener en cuenta en la formulación de un modelo matemático de la osteointegración de implantes dentales.The osteointegration is the structural and functional connection between bone and implant. When an implant is inserted in bone, it creates the so-called bone-implant interphase, a joint zone between implant biomaterial surface and the surrounding bone. The healing of this interphase depends on bone biological conditions, characteristic of implant design and the distribution of loads between bone and implant. The aim of present article is to review of healing process of bone-implant interphase for a dental implant and also to describe the sequence of biological events beginning with lesion caused by implant insertion and leading to the formation of a new bone in the interphase. This description includes a novel classification of mechanical phenomena present in the healing

  6. 21 CFR 872.3640 - Endosseous dental implant.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant. 872.3640 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3640 Endosseous dental implant. (a) Identification. An endosseous dental implant is a device made of a material such as titanium or titanium alloy, that...

  7. Dental implants: A review.

    Science.gov (United States)

    Guillaume, B

    2016-12-01

    A high number of patients have one or more missing tooth and it is estimated that one in four American subjects over the age of 74 have lost all their natural teeth. Many options exist to replace missing teeth but dental implants have become one of the most used biomaterial to replace one (or more) missing tooth over the last decades. Contemporary dental implants made with titanium have been proven safe and effective in large series of patients. This review considers the main historical facts concerned with dental implants and present the different critical factors that will ensure a good osseo-integration that will ensure a stable prosthesis anchorage. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  8. Public perceptions of dental implants: a qualitative study.

    Science.gov (United States)

    Wang, Guihua; Gao, Xiaoli; Lo, Edward C M

    2015-07-01

    Dental implants have become a popular option for treating partially dentate or edentulous patients. Information on dental implants is widely available in the public domain and is disseminated through industries and dental practitioners at various levels/disciplines. This qualitative study aimed to evaluate the public's information acquisition and their perceptions of dental implants and the effects of these on their care-seeking and decision making. A purposive sample of 28 adults were recruited to join six focus groups. To be eligible, one must be 35-64 years of age, had never been engaged in dentally related jobs, had at least one missing tooth, and had heard about dental implant but never received dental implant or entered into any dental consultation regarding dental implants. All of the focus groups discussions were transcribed verbatim and subjected to thematic content analysis following a grounded theory approach. Participants acquired information on dental implants through various means, such as patient information boards, printed advertisements, social media, and personal connections. They expected dental implants to restore the patients' appearance, functions, and quality of life to absolute normality. They regarded dental implants as a panacea for all cases of missing teeth, overestimated their functions and longevity, and underestimated the expertise needed to carry out the clinical procedures. They were deterred from seeking dental implant treatment by the high price, invasive procedures, risks, and complications. Members of the public were exposed to information of varying quality and had some unrealistic expectations regarding dental implants. Such perceptions may shape their care-seeking behaviours and decision-making processes in one way or another. The views and experiences gathered in this qualitative study could assist clinicians to better understand the public's perspectives, facilitate constructive patient-dentist communication, and contribute

  9. Preliminary fabrication and characterization of electron beam melted Ti–6Al–4V customized dental implant

    Directory of Open Access Journals (Sweden)

    Ravikumar Ramakrishnaiah

    2017-05-01

    Full Text Available The current study was aimed to fabricate customized root form dental implant using additive manufacturing technique for the replacement of missing teeth. The root form dental implant was designed using Geomagic™ and Magics™, the designed implant was directly manufactured by layering technique using ARCAM A2™ electron beam melting system by employing medical grade Ti–6Al–4V alloy powder. Furthermore, the fabricated implant was characterized in terms of certain clinically important parameters such as surface microstructure, surface topography, chemical purity and internal porosity. Results confirmed that, fabrication of customized dental implants using additive rapid manufacturing technology offers an attractive method to produce extremely pure form of customized titanium dental implants, the rough and porous surface texture obtained is expected to provide better initial implant stabilization and superior osseointegration.

  10. Oral rehabilitation with dental implants and quality of life following mandibular reconstruction with free fibular flap.

    Science.gov (United States)

    Jacobsen, Hans-Christian; Wahnschaff, Falko; Trenkle, Thomas; Sieg, Peter; Hakim, Samer G

    2016-01-01

    Bony reconstruction of jaw defects using the free fibular flap and dental rehabilitation mostly requires insertion of dental implants within the transferred fibula bone. The aim of this paper was to discuss results of the implant stability with data on the possible benefit for the patient's quality of life after such treatment. For clinical outcome of implants, we evaluated 26 patients with a total number of 94 dental implants after a follow-up period of 12 to 132 months. A group of 38 patients who underwent mandibular reconstruction with free fibular flap could be included in the life-quality study. Evaluation included 23 patients with and 15 patients without implant-borne restoration. The quality of life was assessed using the standard QLQ C-30 questionnaire and the H&N35 module of the European Organisation for Research and Treatment of Cancer (EORTC). Of implants, 94.7 % were stable at the time of investigation and could be used for prosthesis. Patients with dental implants reported improvement of life quality along with better scores in most function and symptom scales; however, only values for global health status (QL2), absence of dyspnea (DY) and absence of feeding tube (HNFE) were significantly better than in the control group. Dental implant insertion in fibula grafts along with implant-borne restoration is a proven concept and might lead to improved quality of life following ablative surgery of the jaw. The effect on the quality of life is not as predictable as on the implant stability. Patients with bony defects of the jaw require bony reconstruction. This allows further masticatory rehabilitation using dental implants and might lead to improved quality of life.

  11. Comparative Evaluation of Osseointegration of Dental Endodontic Implants with and without Plasma- Sprayed Hydroxy apatite Coating

    Directory of Open Access Journals (Sweden)

    Moosavi SB

    2001-05-01

    Full Text Available Bone osseointegration around dental implant can cause earlier stabilization and fixation of implant and reduce healing time. Hydroxyapatite coating can affect bone osseointegration and enhance its rates. The aim of this study was comparison of osseointegration between plasma sprayed hydroxyapatite coated and uncoated dental implants in cats. Four endodontic implants including, vitallium and two stainless steel with and without hydroxyapatite coating were prepared and placed in mandibular canines of 20 cats after completion of root canal treatment and osseous preparation. After a healing period of 4 months, investigation by scanning electron microscopy showed significant difference in ossointegration between coated and uncoated dental implants and average bone osseointegration of coated implants was more than uncoated implants.

  12. Short dental implants versus standard dental implants placed in the posterior jaws: A systematic review and meta-analysis.

    Science.gov (United States)

    Lemos, Cleidiel Aparecido Araujo; Ferro-Alves, Marcio Luiz; Okamoto, Roberta; Mendonça, Marcos Rogério; Pellizzer, Eduardo Piza

    2016-04-01

    The purpose of the present systematic review and meta-analysis was to compare short implants (equal or less than 8mm) versus standard implants (larger than 8mm) placed in posterior regions of maxilla and mandible, evaluating survival rates of implants, marginal bone loss, complications and prosthesis failures. This review has been registered at PROSPERO under the number CRD42015016588. Main search terms were used in combination: dental implant, short implant, short dental implants, short dental implants posterior, short dental implants maxilla, and short dental implants mandible. An electronic search for data published up until September/2015 was undertaken using the PubMed/Medline, Embase and The Cochrane Library databases. Eligibility criteria included clinical human studies, randomized controlled trials and/or prospective studies, which evaluated short implants in comparison to standard implants in the same study. The search identified 1460 references, after inclusion criteria 13 studies were assessed for eligibility. A total of 1269 patients, who had received a total of 2631 dental implants. The results showed that there was no significant difference of implants survival (P=.24; RR:1.35; CI: 0.82-2.22), marginal bone loss (P=.06; MD: -0.20; CI: -0.41 to 0.00), complications (P=.08; RR:0.54; CI: 0.27-1.09) and prosthesis failures (P=.92; RR:0.96; CI: 0.44-2.09). Short implants are considered a predictable treatment for posterior jaws. However, short implants with length less than 8 mm (4-7 mm) should be used with caution because they present greater risks to failures compared to standard implants. Short implants are frequently placed in the posterior area in order to avoid complementary surgical procedures. However, clinicians need to be aware that short implants with length less than 8mm present greater risk of failures. Copyright © 2016. Published by Elsevier Ltd.

  13. Methods to Improve Osseointegration of Dental Implants in Low Quality (Type-IV Bone: An Overview

    Directory of Open Access Journals (Sweden)

    Hamdan S. Alghamdi

    2018-01-01

    Full Text Available Nowadays, dental implants have become more common treatment for replacing missing teeth and aim to improve chewing efficiency, physical health, and esthetics. The favorable clinical performance of dental implants has been attributed to their firm osseointegration, as introduced by Brånemark in 1965. Although the survival rate of dental implants over a 10-year observation has been reported to be higher than 90% in totally edentulous jaws, the clinical outcome of implant treatment is challenged in compromised (bone conditions, as are frequently present in elderly people. The biomechanical characteristics of bone in aged patients do not offer proper stability to implants, being similar to type-IV bone (Lekholm & Zarb classification, in which a decreased clinical fixation of implants has been clearly demonstrated. However, the search for improved osseointegration has continued forward for the new evolution of modern dental implants. This represents a continuum of developments spanning more than 20 years of research on implant related-factors including surgical techniques, implant design, and surface properties. The methods to enhance osseointegration of dental implants in low quality (type-IV bone are described in a general manner in this review.

  14. Methods to Improve Osseointegration of Dental Implants in Low Quality (Type-IV) Bone: An Overview.

    Science.gov (United States)

    Alghamdi, Hamdan S

    2018-01-13

    Nowadays, dental implants have become more common treatment for replacing missing teeth and aim to improve chewing efficiency, physical health, and esthetics. The favorable clinical performance of dental implants has been attributed to their firm osseointegration, as introduced by Brånemark in 1965. Although the survival rate of dental implants over a 10-year observation has been reported to be higher than 90% in totally edentulous jaws, the clinical outcome of implant treatment is challenged in compromised (bone) conditions, as are frequently present in elderly people. The biomechanical characteristics of bone in aged patients do not offer proper stability to implants, being similar to type-IV bone (Lekholm & Zarb classification), in which a decreased clinical fixation of implants has been clearly demonstrated. However, the search for improved osseointegration has continued forward for the new evolution of modern dental implants. This represents a continuum of developments spanning more than 20 years of research on implant related-factors including surgical techniques, implant design, and surface properties. The methods to enhance osseointegration of dental implants in low quality (type-IV) bone are described in a general manner in this review.

  15. Multifunctions of dual Zn/Mg ion co-implanted titanium on osteogenesis, angiogenesis and bacteria inhibition for dental implants.

    Science.gov (United States)

    Yu, Yiqiang; Jin, Guodong; Xue, Yang; Wang, Donghui; Liu, Xuanyong; Sun, Jiao

    2017-02-01

    In order to improve the osseointegration and long-term survival of dental implants, it is urgent to develop a multifunctional titanium surface which would simultaneously have osteogeneic, angiogeneic and antibacterial properties. In this study, a potential dental implant material-dual Zn/Mg ion co-implanted titanium (Zn/Mg-PIII) was developed via plasma immersion ion implantation (PIII). The Zn/Mg-PIII surfaces were found to promote initial adhesion and spreading of rat bone marrow mesenchymal stem cells (rBMSCs) via the upregulation of the gene expression of integrin α1 and integrin β1. More importantly, it was revealed that Zn/Mg-PIII could increase Zn 2+ and Mg 2+ concentrations in rBMSCs by promoting the influx of Zn 2+ and Mg 2+ and inhibiting the outflow of Zn 2+ , and then could enhance the transcription of Runx2 and the expression of ALP and OCN. Meanwhile, Mg 2+ ions from Zn/Mg-PIII increased Mg 2+ influx by upregulating the expression of MagT1 transporter in human umbilical vein endothelial cells (HUVECs), and then stimulated the transcription of VEGF and KDR via activation of hypoxia inducing factor (HIF)-1α, thus inducing angiogenesis. In addition to this, it was discovered that zinc in Zn/Mg-PIII had certain inhibitory effects on oral anaerobic bacteria (Pg, Fn and Sm). Finally, the Zn/Mg-PIII implants were implanted in rabbit femurs for 4 and 12weeks with Zn-PIII, Mg-PIII and pure titanium as controls. Micro-CT evaluation, sequential fluorescent labeling, histological analysis and push-out test consistently demonstrated that Zn/Mg-PIII implants exhibit superior capacities for enhancing bone formation, angiogenesis and osseointegration, while consequently increasing the bonding strength at bone-implant interfaces. All these results suggest that due to the multiple functions co-produced by zinc and magnesium, rapid osseointegration and sustained biomechanical stability are enhanced by the novel Zn/Mg-PIII implants, which have the potential

  16. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices intended...

  17. 21 CFR 872.3630 - Endosseous dental implant abutment.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant abutment. 872.3630... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3630 Endosseous dental implant abutment. (a) Identification. An endosseous dental implant abutment is a premanufactured prosthetic component...

  18. Improving osseointegration of dental implants.

    Science.gov (United States)

    Elias, Carlos Nelson; Meirelles, Luiz

    2010-03-01

    In the beginning of implantology, the procedures adopted for treating patients were performed in two surgical phases with an interval of 3-6 months. Nowadays, it is possible to insert and load a dental implant in the same surgical procedure. This change is due to several factors, such as improvement of surgical technique, modifications of the implant design, increased quality of implant manufacturing, development of the surgical instruments' quality, careful patient screening and adequate treatment of the implant surface. The clinical results show that adequate treatment of surfaces is crucial for reducing healing time and treating at-risk patients. The surface properties of dental implants can be significantly improved at the manufacturing stage, affecting cells' activity during the healing phase that will ultimately determine the host tissue response, a fundamental requirement for clinical success. This review focuses on different types of dental implant surfaces and the influence of surface characteristics on osseointegration.

  19. Differences in knowledge related to dental implants between patients with and without a treatment history of dental implants.

    Science.gov (United States)

    Ken, Yukawa; Tachikawa, Noriko; Kasugai, Shohei

    2017-09-01

    This aim of this study was to investigate the differences between patients with and without a treatment history of dental implants by use of a questionnaire survey in order to determine the information that is required for patients undergoing dental implants. The questionnaires were given to 4512 patients who visited the Tokyo Medical and Dental University Hospital for oral implants between January 2012 and December 2014, and 2972 (66%) valid questionnaires were collected. There were 857 patients with a treatment history of dental implants and 2115 patients without. "Preservation of an adjacent tooth" was the reason that 32% of these patients chose implant therapy, and the patients without treatment history were significantly higher than the patients with one. Significantly, more patients without a treatment history of dental implants selected the after-effects of surgery and pain after surgery as their main concerns for implant therapy compared to those with a treatment history. In the question "Pain after surgery," the patients without treatment history did not know significantly lower than the patients with one. Patients without a treatment history of dental implants placed more importance on the preservation of healthy teeth. Because patients, in particular those without a treatment history of dental implants, are anxious about surgery, we should provide them with more information on treatment than we already do and explain the risks of treatment to them. To keep the credence between doctors and patients, informed consent and patient education on treatment are six important concerns. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. [The impact of dental implants

    NARCIS (Netherlands)

    Meijer, G.J.

    2013-01-01

    The importance of the introduction of dental implants can only be understood when the historical context is clarified. In the past, the main treatment carried out by dentists consisted of filling or, in unfortunate cases, removal of painful teeth. Only since the introduction of dental implants did

  1. Surface modifications of dental implants.

    Science.gov (United States)

    Stanford, C M

    2008-06-01

    Dental implant surface technologies have been evolving rapidly to enhance a more rapid bone formation on their surface and hold a potential to increase the predictability of expedited implant therapy. While implant outcomes have become highly predictable, there are sites and conditions that result in elevated implant loss. This paper reviews the impact of macro-retentive features which includes approaches to surface oxide modification, thread design, press-fit and sintered-bead technologies to increase predictability of outcomes. Implant designs that lead to controlled lateral compression of the bone can improve primary stability as long as the stress does not exceed the localized yield strength of the cortical bone. Some implant designs have reduced crestal bone loss by use of multiple cutting threads that are closely spaced, smoothed on the tip but designed to create a hoop-stress stability of the implant as it is completely seated in the osteotomy. Following the placement of the implant, there is a predictable sequence of bone turnover and replacement at the interface that allows the newly formed bone to adapt to microscopic roughness on the implant surface, and on some surfaces, a nanotopography (<10(-9) m scale) that has been shown to preferably influence the formation of bone. Newly emerging studies show that bone cells are exquisitely sensitive to these topographical features and will upregulate the expression of bone related genes for new bone formation when grown on these surfaces. We live in an exciting time of rapid changes in the modalities we can offer patients for tooth replacement therapy. Given this, it is our responsibility to be critical when claims are made, incorporate into our practice what is proven and worthwhile, and to continue to support and provide the best patient care possible.

  2. Dental implants in medically complex patients-a retrospective study.

    Science.gov (United States)

    Manor, Yifat; Simon, Roy; Haim, Doron; Garfunkel, Adi; Moses, Ofer

    2017-03-01

    Dental implant insertion for oral rehabilitation is a worldwide procedure for healthy and medically compromised patients. The impact of systemic disease risks on the outcome of implant therapy is unclear, since there are few if any published randomized controlled trials (RCTs). The objective of this study is to investigate the rate of complications and failures following dental implantation in medically compromised patients in order to elucidate risk factors and prevent them. A retrospective cohort study was conducted from patient files treated with dental implantation between the years 2008-2014. The study group consisted of medically complex patients while the control group consisted of healthy patients. Preoperative, intraoperative, and post operative clinical details were retrieved from patients' files. The survival rate and the success rate of the dental implants were evaluated clinically and radiographically. A total of 204 patients (1003 dental implants) were included in the research, in the study group, 93 patients with 528 dental implants and in the control group, 111 patients with 475 dental implants. No significant differences were found between the groups regarding implant failures or complications. The failure rate of dental implants among the patients was 11.8 % in the study group and 16.2 % in the control group (P = 0.04). It was found that patients with a higher number of implants (mean 6.8) had failures compared with patients with a lower number of implants (mean 4.2) regardless of their health status (P dental implantation in medically complex patients and in healthy patients. Medically complex patients can undergo dental implantation. There are similar rates of complications and failures of dental implants in medically complex patients and in healthy patients.

  3. Nanotechnology for dental implants.

    Science.gov (United States)

    Tomsia, Antoni P; Lee, Janice S; Wegst, Ulrike G K; Saiz, Eduardo

    2013-01-01

    With the advent of nanotechnology, an opportunity exists for the engineering of new dental implant materials. Metallic dental implants have been successfully used for decades, but they have shortcomings related to osseointegration and mechanical properties that do not match those of bone. Absent the development of an entirely new class of materials, faster osseointegration of currently available dental implants can be accomplished by various surface modifications. To date, there is no consensus regarding the preferred method(s) of implant surface modification, and further development will be required before the ideal implant surface can be created, let alone become available for clinical use. Current approaches can generally be categorized into three areas: ceramic coatings, surface functionalization, and patterning on the micro- to nanoscale. The distinctions among these are imprecise, as some or all of these approaches can be combined to improve in vivo implant performance. These surface improvements have resulted in durable implants with a high percentage of success and long-term function. Nanotechnology has provided another set of opportunities for the manipulation of implant surfaces in its capacity to mimic the surface topography formed by extracellular matrix components of natural tissue. The possibilities introduced by nanotechnology now permit the tailoring of implant chemistry and structure with an unprecedented degree of control. For the first time, tools are available that can be used to manipulate the physicochemical environment and monitor key cellular events at the molecular level. These new tools and capabilities will result in faster bone formation, reduced healing time, and rapid recovery to function.

  4. Diagnostic Imaging for Dental Implant Therapy

    Directory of Open Access Journals (Sweden)

    Aishwarya Nagarajan

    2014-01-01

    Full Text Available Dental implant is a device made of alloplastic (foreign material implanted into the jaw bone beneath the mucosal layer to support a fixed or removable dental prosthesis. Dental implants are gaining immense popularity and wide acceptance because they not only replace lost teeth but also provide permanent restorations that do not interfere with oral function or speech or compromise the self-esteem of a patient. Appropriate treatment planning for replacement of lost teeth is required and imaging plays a pivotal role to ensure a satisfactory outcome. The development of pre-surgical imaging techniques and surgical templates helps the dentist place the implants with relative ease. This article focuses on various types of imaging modalities that have a pivotal role in implant therapy.

  5. Effect of Heavy Smoking on Dental Implants Placed in Male Patients Posterior Mandibles: A Prospective Clinical Study.

    Science.gov (United States)

    Sun, Cong; Zhao, Jinxiu; Jianghao, Chen; Hong, Tao

    2016-12-01

    The objective of this study was to evaluate the implant stability and peri-implant tissue response in heavy smokers receiving dental implants due to partially edentulous posterior mandibles. Forty-five ITI Straumann dental implants were placed into the partially edentulous posterior mandibles of 16 heavy smokers and 16 nonsmokers. One implant in each patient was evaluated for implant stability after surgery and before loading, and for the modified plaque index (mPLI), modified sulcus bleeding index (mSBI), probing depth (PD), and marginal bone loss (MBL) after loading. Meanwhile, the osteogenic capability of jaw marrow samples collected from patients was evaluated via an in vitro mineralization test. For both groups, the implant stability quotient (ISQ) initially decreased from the initial ISQ achieved immediately after surgery and then increased starting from 2 weeks postsurgery. However, at 3, 4, 6, and 8 weeks postsurgery, the ISQ differed significantly between nonsmokers and heavy smokers. All implants achieved osseointegration without complications at least by the end of the 12th week postsurgery. At 6 or 12 months postloading, the MBL and PD were significantly higher in heavy smokers than in nonsmokers, whereas the mSBI and mPLI did not differ significantly between the 2 groups. The 1-year cumulative success rate of implants was 100% for both groups. Within the limitations of the present clinical study (such as small sample size and short study duration), which applied the loading at 3 months postoperation, heavy smoking did not affect the cumulative survival rate of dental implants placed at the posterior mandible in male patients, but heavy smoking did negatively affect bone healing around dental implants by decreasing the healing speed. These results implied that it might be of importance to select the right time point to apply the implant loading for heavy smokers. In addition, heavy smoking promoted the loss of marginal bone and the further development

  6. The Role of Bioceramics Coating in Dental Implant Reliability and Success

    Directory of Open Access Journals (Sweden)

    Mortazavi V

    2000-05-01

    Full Text Available Characterization of bioceramics coating and evaluation of the influence of kind of coating on"nthe implantation has been developed in recent years."nDifferent bioceramics coating like calcium phosphate, hydroxyapatite, fluorapatite and bioglass were"ncoated on dental and orthopedic implants. In-vitro and in-vivo experiments were done for evolution of"nimplant success and reliability and study of factors, which may influence the results."nResearches indicate that different bioceramic coating may affect the bone bonding mechanism."nBiodegredable calcium phosphate coating can be resorbed and be replaced with bone tissues."nHydroxyapatite cause earlier stabilization of dental implant in surrounding bone (biological fixation and"nreduce healing time. Bioglass can protect substrate and provide interfacial attachment to bone.

  7. Osseoperception in Dental Implants: A Systematic Review.

    Science.gov (United States)

    Mishra, Sunil Kumar; Chowdhary, Ramesh; Chrcanovic, Bruno Ramos; Brånemark, Per-Ingvar

    2016-04-01

    Replacement of lost teeth has significant functional and psychosocial effects. The capability of osseointegrated dental implants to transmit a certain amount of sensibility is still unclear. The phenomenon of developing a certain amount of tactile sensibility through osseointegrated dental implants is called osseoperception. The aim of this article is to evaluate the available literature to find osseoperception associated with dental implants. To identify suitable literature, an electronic search was performed using Medline and PubMed database. Articles published in English and articles whose abstract is available in English were included. The articles included in the review were based on osseoperception, tactile sensation, and neurophysiological mechanoreceptors in relation to dental implants. Articles on peri-implantitis and infection-related sensitivity were not included. Review articles without the original data were excluded, although references to potentially pertinent articles were noted for further follow-up. The phenomenon of osseoperception remains a matter of debate, so the search strategy mainly focused on articles on osseoperception and tactile sensibility of dental implants. This review presents the histological, neurophysiological, and psychophysical evidence of osseoperception and also the role of mechanoreceptors in osseoperception. The literature on osseoperception in dental implants is very scarce. The initial literature search resulted in 90 articles, of which 81 articles that fulfilled the inclusion criteria were included in this systematic review. Patients restored with implant-supported prostheses reported improved tactile and motor function when compared with patients wearing complete dentures. © 2016 by the American College of Prosthodontists.

  8. Short dental implants: A scoping review of the literature for patients with head and neck cancer.

    Science.gov (United States)

    Edher, Faraj; Nguyen, Caroline T

    2017-09-16

    Dental implants can be essential in the rehabilitation of various cancer defects, but their ideal placement can be complicated by the limited dimensions of the available host bone. Surgical interventions developed to increase the amount of bone are not all predictable or successful and can sometimes be contraindicated. Short dental implants have been suggested as an alternative option in sites where longer implants are not possible. Whether they provide a successful treatment option is unclear. The purpose of this study was to review the literature on short dental implants and assess whether they are a viable definitive treatment option for rehabilitating cancer patients with deficient bone. A scoping review of the literature was performed, including a search of established periodontal textbooks for articles on short dental implants combined with a search of PubMed, MEDLINE, EMBASE, Web of Science, and Cochrane Database of Systematic Reviews. A search for all literature published before June 2016 was based on the following keywords: ['dental implants' OR 'dental implantation, endosseous' OR 'dental prosthesis, implant supported'] AND [short]. The minimum acceptable implant length has been considered to be 6 mm. The survival rates of short implants varied between 74% and 96% at 5 years, depending on factors such as the quality of the patient's bone, primary stability of the implant, clinician's learning curve, and implant surface. Short implants can achieve results similar to those of longer implants in augmented bone and offer a treatment alternative that could reduce the need for invasive surgery and associated morbidity and be safer and more economical. Short dental implants (6 mm to 8 mm) can be used successfully to support single or multiple fixed reconstructions or overdentures in atrophic maxillae and mandibles. The use of short dental implants lessens the need for advanced and complicated surgical bone augmentation procedures, which reduces complications

  9. Systemic Assessment of Patients Undergoing Dental Implant ...

    African Journals Online (AJOL)

    Background: Procedure‑related and patient‑related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty‑one patients were included in the study, in which a total of 110 dental ...

  10. Biofilm and dental implant: The microbial link

    Directory of Open Access Journals (Sweden)

    Sangeeta Dhir

    2013-01-01

    Full Text Available Mouth provides a congenial environment for the growth of the microorganisms as compared to any other part of the human body by exhibiting an ideal nonshedding surface. Dental plaque happens to be a diverse community of the microorganisms found on the tooth surface. Periodontal disease and the peri-implant disease are specific infections that are originating from these resident microbial species when the balance between the host and the microbial pathogenicity gets disrupted. This review discusses the biofilms in relation to the peri-implant region, factors affecting its presence, and the associated treatment to manage this complex microbial colony. Search Methodology: Electronic search of the medline was done with the search words: Implants and biofilms/dental biofilm formation/microbiology at implant abutment interface/surface free energy/roughness and implant, periimplantitis/local drug delivery and dental implant. Hand search across the journals - clinical oral implant research, implant dentistry, journal of dental research, international journal of oral implantology, journal of prosthetic dentistry, perioodntology 2000, journal of periodontology were performed. The articles included in the review comprised of in vivo studies, in vivo (animal and human studies, abstracts, review articles.

  11. Relation between bruxism and dental implants

    OpenAIRE

    TORCATO,Leonardo Bueno; ZUIM,Paulo Renato Junqueira; BRANDINI,Daniela Atili; FALCÓN-ANTENUCCI,Rosse Mary

    2014-01-01

    OBJECTIVE: The aim of this study was to gather information and discuss the predictability of implant-supported prostheses in patients with bruxism by performing a literature review.METHODS: In order to select the studies included in this review, a detailed search was performed in PubMed and Medlinedatabases, using the following key words: bruxism, dental implants, implant supported prosthesis, and dental restoration failure. Items that were included are: case reports, randomized controlled tr...

  12. Quality of YouTube TM videos on dental implants.

    Science.gov (United States)

    Abukaraky, A; Hamdan, A-A; Ameera, M-N; Nasief, M; Hassona, Y

    2018-07-01

    Patients search YouTube for health-care information. To examine what YouTube offers patients seeking information on dental implants, and to evaluate the quality of provided information. A systematic search of YouTube for videos containing information on dental implants was performed using the key words Dental implant and Tooth replacement. Videos were examined by two senior Oral and Maxillofacial Surgery residents who were trained and calibrated to perform the search. Initial assessment was performed to exclude non- English language videos, duplicate videos, conference lectures, and irrelevant videos. Included videos were analyzed with regard to demographics and content's usefulness. Information for patients available from the American Academy of Implant Dentistry, European Association of Osseointegration, and British Society of Restorative Dentistry were used for benchmarking. A total of 117 videos were analyzed. The most commonly discussed topics were related to procedures involved in dental implantology (76.1%, n=89), and to the indications for dental implants (58.1%, n=78). The mean usefulness score of videos was poor (6.02 ±4.7 [range 0-21]), and misleading content was common (30.1% of videos); mainly in topics related to prognosis and maintenance of dental implants. Most videos (83.1%, n=97) failed to mention the source of information presented in the video or where to find more about dental implants. Information about dental implants on YouTube is limited in quality and quantity. YouTube videos can have a potentially important role in modulating patients attitude and treatment decision regarding dental implants.

  13. Porous Titanium for Dental Implant Applications

    Directory of Open Access Journals (Sweden)

    Zena J. Wally

    2015-10-01

    Full Text Available Recently, an increasing amount of research has focused on the biological and mechanical behavior of highly porous structures of metallic biomaterials, as implant materials for dental implants. Particularly, pure titanium and its alloys are typically used due to their outstanding mechanical and biological properties. However, these materials have high stiffness (Young’s modulus in comparison to that of the host bone, which necessitates careful implant design to ensure appropriate distribution of stresses to the adjoining bone, to avoid stress-shielding or overloading, both of which lead to bone resorption. Additionally, many coating and roughening techniques are used to improve cell and bone-bonding to the implant surface. To date, several studies have revealed that porous geometry may be a promising alternative to bulk structures for dental implant applications. This review aims to summarize the evidence in the literature for the importance of porosity in the integration of dental implants with bone tissue and the different fabrication methods currently being investigated. In particular, additive manufacturing shows promise as a technique to control pore size and shape for optimum biological properties.

  14. Damping Factor as a Diagnostic Parameter for Assessment of Osseointegration during the Dental Implant Healing Process: An Experimental Study in Rabbits.

    Science.gov (United States)

    Feng, Sheng-Wei; Ho, Kuo-Ning; Chan, Ya-Hui; Chang, Kai-Jung; Lai, Wei-Yi; Huang, Haw-Ming

    2016-12-01

    The purpose of this study was to evaluate the possibility of using damping factor (DF) analysis to provide additional information on osseointegration of dental implants during the healing period. A total of 30 dental implants were installed in the bilateral femoral condyles of 15 rabbits. A DF analyzer detected with an impulse-forced vibration method and a commercialized dental implant stability analyzer based on resonance frequency (RF) analysis were used to measure the implant stability immediately after implant placement and 1, 2, 4, and 8 weeks post-surgically. Results of DF and RF analyses at different time points were compared with the corresponding osseointegration performance of dental implants via micro-computed tomography (micro-CT), histological and histomorphometrical analysis. The DF values revealed a decrease with time and reached 0.062 ± 0.007 at 8 weeks after implantation, which is almost 50% lower than the initial value. Moreover, highly significant correlations between DF values and bone volume densities (R 2  = 0.9797) and percentages of bone-to-implant contact measured at trabecular bone area (R 2  = 0.9773) were also observed. These results suggested that DF analysis combined with RF analysis results in a more sensitive assessment of changes in the dental implant/bone complex during the healing period than RF analysis alone.

  15. Image-guided navigation system for placing dental implants.

    Science.gov (United States)

    Casap, Nardy; Wexler, Alon; Lustmann, Joshua

    2004-10-01

    Navigation-guided surgery has recently been introduced into various surgical disciplines, including oral and maxillofacial surgery. Since the advent of dental implants, dental computed tomography (CT) scans have been used as a diagnostic tool for preoperative planning, but not as part of the surgical phase. This article explains the principles of computer-assisted surgery and describes the use of a computer-guided navigation system in dental implantology. The system uses preoperative dental CT scans for planning and as an integral part of the surgical procedure. This system allows continuous intraoperative coordination of the implantation phase with the preoperative plan, optimizing the accuracy of implant surgery. Deviations from the planned location of the implants are minimal. Several cases are discussed.

  16. Predicting the Failure of Dental Implants Using Supervised Learning Techniques

    Directory of Open Access Journals (Sweden)

    Chia-Hui Liu

    2018-05-01

    Full Text Available Prosthodontic treatment has been a crucial part of dental treatment for patients with full mouth rehabilitation. Dental implant surgeries that replace conventional dentures using titanium fixtures have become the top choice. However, because of the wide-ranging scope of implant surgeries, patients’ body conditions, surgeons’ experience, and the choice of implant system should be considered during treatment. The higher price charged by dental implant treatments compared to conventional dentures has led to a rush among medical staff; therefore, the future impact of surgeries has not been analyzed in detail, resulting in medial disputes. Previous literature on the success factors of dental implants is mainly focused on single factors such as patients’ systemic diseases, operation methods, or prosthesis types for statistical correlation significance analysis. This study developed a prediction model for providing an early warning mechanism to reduce the chances of dental implant failure. We collected the clinical data of patients who received artificial dental implants at the case hospital for a total of 8 categories and 20 variables. Supervised learning techniques such as decision tree (DT, support vector machines, logistic regressions, and classifier ensembles (i.e., Bagging and AdaBoost were used to analyze the prediction of the failure of dental implants. The results show that DT with both Bagging and Adaboost techniques possesses the highest prediction performance for the failure of dental implant (area under the receiver operating characteristic curve, AUC: 0.741; the analysis also revealed that the implant systems affect dental implant failure. The model can help clinical surgeons to reduce medical failures by choosing the optimal implant system and prosthodontics treatments for their patients.

  17. Dual-modal photoacoustic and ultrasound imaging of dental implants

    Science.gov (United States)

    Lee, Donghyun; Park, Sungjo; Kim, Chulhong

    2018-02-01

    Dental implants are common method to replace decayed or broken tooth. As the implant treatment procedures varies according to the patients' jawbone, bone ridge, and sinus structure, appropriate examinations are necessary for successful treatment. Currently, radiographic examinations including periapical radiology, panoramic X-ray, and computed tomography are commonly used for diagnosing and monitoring. However, these radiographic examinations have limitations in that patients and operators are exposed to radioactivity and multiple examinations are performed during the treatment. In this study, we demonstrated photoacoustic (PA) and ultrasound (US) combined imaging of dental implant that can lower the total amount of absorbed radiation dose in dental implant treatment. An acoustic resolution PA macroscopy and a clinical PA/US system was used for dental implant imaging. The acquired dual modal PA/US imaging results support that the proposed photoacoustic imaging strategy can reduce the radiation dose rate during dental implant treatment.

  18. Dental Implants and General Dental Practitioners of Nepal: A study of existing knowledge and need for further education

    Directory of Open Access Journals (Sweden)

    Bhageshwar Dhami

    2017-03-01

    Full Text Available Background & Objectives: The use of dental implants in partially or completely edentulous patients has proved effective and an accepted treatment modality with predictable long-term success. Dental implants are becoming a popular choice for replacing the missing teeth because of increased awareness about implants both in dentists and patients. The objective of the study was to assess the basic knowledge and education about dental implants among general dental practitioners (GDPs of Nepal.Materials & Methods:  A cross sectional questionnaire was carried out among 110 GDPs which consist of twenty questions that were divided into three categories; first with some basic knowledge in implant dentistry, second with clinical knowledge of dental implants and third with dental implant education and training.Results: Out of 110 GDPs, 72.7% had basic knowledge about implant dentistry and 65.5% were not aware about advance surgical procedures like sinus lift and guided bone regeneration. All the GDPs were positive regarding more training and education in dental implants and 95.5% of them would like to incorporate dental implant treatment in their practice in future. Conclusion: GDPs should have adequate knowledge and training of dental implants which can be incorporated at undergraduate or post doctoral level so that they are skilled to provide quality dental implant therapy to their patients confidently.

  19. Radiographic examination for successful dental implant

    International Nuclear Information System (INIS)

    Lee, Sam Sun; Choi, Soon Chul

    2005-01-01

    Recently implant has become an important field in dental clinic. Radiographic examination of pre- and post-operation is essential for successful treatment. Clinicians should have knowledge about the purpose of the radiographic examination, suitable imaging modality for the cases, anatomic landmarks of tooth and jaw bone, advantage and limitation of panoramic radiographic examination for implant, principle and interpretation of cross-sectional imaging, bone mineral density, post-operative radiographic examination. This paper will be helpful to get above information for dentists who want to do dental implant successfully.

  20. Survival of dental implants placed in sites of previously failed implants.

    Science.gov (United States)

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. On stress/strain shielding and the material stiffness paradigm for dental implants.

    Science.gov (United States)

    Korabi, Raoof; Shemtov-Yona, Keren; Rittel, Daniel

    2017-10-01

    Stress shielding considerations suggest that the dental implant material's compliance should be matched to that of the host bone. However, this belief has not been confirmed from a general perspective, either clinically or numerically. To characterize the influence of the implant stiffness on its functionality using the failure envelope concept that examines all possible combinations of mechanical load and application angle for selected stress, strain and displacement-based bone failure criteria. Those criteria represent bone yielding, remodeling, and implant primary stability, respectively MATERIALS AND METHODS: We performed numerical simulations to generate failure envelopes for all possible loading configurations of dental implants, with stiffness ranging from very low (polymer) to extremely high, through that of bone, titanium, and ceramics. Irrespective of the failure criterion, stiffer implants allow for improved implant functionality. The latter reduces with increasing compliance, while the trabecular bone experiences higher strains, albeit of an overall small level. Micromotions remain quite small irrespective of the implant's stiffness. The current paradigm favoring reduced implant material's stiffness out of concern for stress or strain shielding, or even excessive micromotions, is not supported by the present calculations, that point exactly to the opposite. © 2017 Wiley Periodicals, Inc.

  2. Bacteremia following dental implant surgery: preliminary results.

    Science.gov (United States)

    Bölükbaşı, Nilüfer; Özdemir, Tayfun; Öksüz, Lütfiye; Gürler, Nezahat

    2012-01-01

    The aims of this study were to investigate the incidence of bacteremia, bacteriology and antibiotic susceptibility against to causative bacteria associated with dental implant installation. 30 generally healthy patients were enrolled in this study. Blood samples were collected at baseline and at 30 minutes after dental implant installation and 24 hours after dental implant surgery. Blood samples were cultured in a BACTEC system. The isolated bacteria were identified using conventional methods. Antimicrobial sensitivity tests were performed by disc diffusion. No bacteria were isolated at the baseline and 24 hours after surgery, whereas the prevalence of bacteremia at 30 minutes after dental implant installation was 23%. The isolated bacteria species were Staphylococcus epidermidis, Eubacterium spp., Corynebacterium spp. and Streptococcus viridans. The Staphylococcus epidermidis, which was isolated in three patients, was found to be resistant to penicillin which is first choice of many clinicians. Our findings suggest that installation of dental implants can produce bacteremia. Within the limitations of this study, it can be speculated that the resistance of antibiotics may compromise the routine prophylaxis against infective endocarditis. Therefore use of blood cultures and antibiograms may be suggested in risky patients. The outcome of the present study should be verified using a larger patient group with varying conditions.

  3. Reconstruction of the maxilla following hemimaxillectomy defects with scapular tip grafts and dental implants.

    Science.gov (United States)

    Mertens, Christian; Freudlsperger, Christian; Bodem, Jens; Engel, Michael; Hoffmann, Jürgen; Freier, Kolja

    2016-11-01

    Treatment of post-resective defects of the maxilla can be challenging and usually requires dental obturation or microvascular reconstruction. As compared to soft-tissue microvascular grafts, bone reconstruction can additionally allow for facial support and retention of dental implants. The aim of this study was to evaluate scapular tip grafts with respect to their applicability for maxillary reconstruction and their potential to retain dental implants for later dental rehabilitation. In this retrospective study, 14 patients with hemimaxillectomy defects were reconstructed with free scapular tip grafts, oriented horizontally, to rebuild the palate and alveolar ridge. After bone healing, three-dimensional virtual implant planning was performed, and a radiographic guide was fabricated to enable implant placement in the optimal anatomic and prosthetic position. All patients' mastication and speech were evaluated, along with the extent of defect closure, suitability of the graft sites for implant placement, and soft-tissue stability. Pre- and postsurgical radiographs were also evaluated. A good postoperative outcome was achieved in all patients, with complete closure of maxillary defects that were class II, according to the system of Brown and Shaw. Additional bone augmentation was necessary in two patients in order to increase vertical bone height. Patients were subsequently treated with 50 dental implants to retain dental prostheses. In all cases, additional soft-tissue surgery was necessary to achieve a long-term stable periimplant situation. No implants were lost during the mean observation period of 34 months. Due to its specific form, the scapular tip graft is well suited to reconstruct the palate and maxillary alveolar ridge and to enable subsequent implant-retained rehabilitation. Due to the limited bone volume, an accurate three-dimensional graft orientation is essential. Furthermore, most cases require additional soft-tissue surgery to achieve a long

  4. Straightforward Case of Dental Implant in General Dentistry

    Directory of Open Access Journals (Sweden)

    Aji P. Tjikman

    2013-07-01

    Full Text Available Dental implant has become a fast developing and dynamic field in dental practice. It is acknowledged as a predictable treatment modality with high clinical success rates. Conventional fixed prostheses are no longer considered to be the first choice of treatment for replacing a missing tooth. Despite the increasing number of patients requesting dental implant treatments, there are only some clinicians who are offering implant therapy in their daily practice. The International team for Implantology described a straightforward case as a simple case such as implant placements in adquate soft and hard tissue conditions and single-tooth restorations in a non-aesthetic zone. A review of the current literature discussed the implementation of implant dentistry in universities worldwide into their curriculum for both undergraduate and postgraduate programs in general dentistry. The European consensus in implant dentistry education concluded that it is desirable to include the surgical technique for implant placement for straightforward cases into the dental curriculum. The levels and limitations to which the various aspects of implant dentistry and related skills are taught to be determined by the academic community. This review aimed at promoting awareness amongst dental practitioners and institutions in Indonesia of the shifting treatment paradigm in the maangement of a missing tooth. Hence clinicians will be able to include implant dentistry in the treatment planning of their patients and also undertake a significant part in the execution of such treatments.

  5. Dental-Implantate und ihre Werkstoffe

    Science.gov (United States)

    Newesely, Heinrich

    1983-07-01

    Some new trends in materials for dental implants, which also effect in the operative techniques and implant design, are described. Advantages and shortcomings of the different material types are exemplified and correlated with their bioinert resp. bioactive functions. The practical interest in metallic implants focussed in titanium resp. oxide ceramics in the ceramic field, whereas the special goal of implant research follows from the improvement of the bioactive principle with loaded calcium phosphate implants.

  6. Analytical and experimental position stability of the abutment in different dental implant systems with a conical implant?abutment connection

    OpenAIRE

    Semper-Hogg, Wiebke; Kraft, Silvan; Stiller, Sebastian; Mehrhof, Juergen; Nelson, Katja

    2012-01-01

    Objectives Position stability of the abutment should be investigated in four implant systems with a conical implant?abutment connection. Materials and methods Previously developed formulas and an established experimental setup were used to determine the position stability of the abutment in the four implant systems with a conical implant?abutment connection and different positional index designs: The theoretical rotational freedom was calculated by using the dimensions of one randomly selecte...

  7. Readability of websites containing information on dental implants.

    Science.gov (United States)

    Jayaratne, Yasas S N; Anderson, Nina K; Zwahlen, Roger A

    2014-12-01

    It is recommended that health-related materials for patients be written at sixth grade level or below. Many websites oriented toward patient education about dental implants are available, but the readability of these sites has not been evaluated. To assess readability of patient-oriented online information on dental implants. Websites containing patient-oriented information on dental implants were retrieved using the Google search engine. Individual and mean readability/grade levels were calculated using standardized formulas. Readability of each website was classified as easy (≤ 6th-grade level) or difficult (≥ 10th grade level). Thirty nine websites with patient-oriented information on dental implant were found. The average readability grade level of these websites was 11.65 ± 1.36. No website scored at/below the recommended 6th grade level. Thirty four of 39 websites (87.18%) were difficult to read. The number of characters, words, and sentences on these sites varied widely. All patient-oriented websites on dental implants scored above the recommended grade level, and majority of these sites were "difficult" in their readability. There is a dire need to create patient information websites on implants, which the majority can read. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Knowledge and attitude of elderly persons towards dental implants.

    Science.gov (United States)

    Müller, Frauke; Salem, Kamel; Barbezat, Cindy; Herrmann, François R; Schimmel, Martin

    2012-06-01

    Despite their unrivalled place in restorative treatment, dental implants are still scarcely used in elderly patients. The aim of this survey was therefore to identify potential barriers for accepting an implant treatment. Participants were recruited from a geriatric hospital, two long-term-care facilities and a private clinic. The final study sample comprised 92 persons, 61 women and 31 men with an average age of 81.2 ± 8.0 years. In a semi-structured interview, the participants' knowledge of implants and attitude towards a hypothetical treatment with dental implants were evaluated. Twenty-seven participants had never heard of dental implants, and another 13 participants could not describe them. The strongest apprehensions against implants were cost, lack of perceived necessity and old age. Univariate and multiple linear regression analysis identified being women, type and quality of denture, having little knowledge on implants and being hospitalised as the risk factors for refusing implants. However, old age as such was not associated with a negative attitude. The acceptance of dental implants in the elderly population might be increased by providing further information and promoting oral health in general. Regardless of the age, dental implants should be placed when patients are still in good health and live independently. © 2011 The Gerodontology Society and John Wiley & Sons A/S.

  9. The Mechanical Behaviors of Various Dental Implant Materials under Fatigue

    Directory of Open Access Journals (Sweden)

    Fatma Bayata

    2018-01-01

    Full Text Available The selection of materials has a considerable role on long-term stability of implants. The materials having high resistance to fatigue are required for dental implant applications since these implants are subjected to cyclic loads during chewing. This study evaluates the performance of different types of materials (AISI 316L stainless steel, alumina and its porous state, CoCr alloys, yttrium-stabilized zirconia (YSZ, zirconia-toughened alumina (ZTA, and cp Ti with the nanotubular TiO2 surface by finite element analysis (FEA under real cyclic biting loads and researches the optimum material for implant applications. For the analysis, the implant design generated by our group was utilized. The mechanical behavior and the life of the implant under biting loads were estimated based on the material and surface properties. According to the condition based on ISO 14801, the FEA results showed that the equivalent von Mises stress values were in the range of 226.95 MPa and 239.05 MPa. The penetration analysis was also performed, and the calculated penetration of the models onto the bone structure ranged between 0.0037389 mm and 0.013626 mm. L-605 CoCr alloy-assigned implant model showed the least penetration, while cp Ti with the nanotubular TiO2 surface led to the most one. However, the difference was about 0.01 mm, and it may not be evaluated as a distinct difference. As the final numerical evaluation item, the fatigue life was executed, and the results were achieved in the range of 4 × 105 and 1 × 109 cycles. These results indicated that different materials showed good performance for each evaluation component, but considering the overall mechanical performance and the treatment process (implant adsorption by means of surface properties, cp Ti with the nanotubular TiO2 surface material was evaluated as the suitable one, and it may also be implied that it displayed enough performance in the designed dental implant model.

  10. Prefabricated fibula free flap with dental implants for mandibular reconstruction.

    Science.gov (United States)

    Pauchet, D; Pigot, J-L; Chabolle, F; Bach, C-A

    2018-03-02

    Free fibula transplant is routinely used for mandibular reconstruction in head and neck cancer. Dental rehabilitation, the objective of mandibular reconstruction, requires the use of dental implants as supports for fixed or removable dentures. Positioning of fibular bone grafts and implants determines implant osseointegration and the possibilities of dental rehabilitation. Prefabrication of a fibula free flap with dental implants prior to harvesting as a free flap can promote implant osseointegration. The position of the implants must then be precisely planned. Virtual surgery and computer-assisted design and prefabrication techniques are used to plan the reconstruction and then reproduce this planning by means of tailored fibula and mandible cutting guides, thereby ensuring correct positioning of fibular bone fragments and implants. The prefabricated fibula free flap technique requires two surgical procedures (prefabrication and flap transfer) and precise preoperative planning. Prefabricated fibula free flap with dental implants, by improving the quality of osseointegration of the implants before flap transfer, extends the possibilities of prosthetic rehabilitation in complex secondary mandibular reconstructions. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  11. Systemic Assessment of Patients Undergoing Dental Implant ...

    African Journals Online (AJOL)

    These days, dental implants are becoming routinely used as a treatment option for rehabilitation of lost teeth. Conventionally, it is only after the completion of bone healing that the dental implants are loaded into the bone. Bone healing time is approximately 3 months and. 6 months for the mandible and maxilla, respectively.

  12. Měření primární stability dentálního implantátu a její ovlivnění designem implantátu

    OpenAIRE

    Dzan, Ladislav

    2017-01-01

    1 SUMMARY Measurement of primary stability of the dental implant and the influence of the implant de- sign Primary stability is the lack of mobility in the bone after an implant insertion and it is conditioned by the quality and quantity of the bone, the surgical technique and the skill of the surgeon. Another element is the micro-design and especially macro-design of the implant, whose influence on the primary stability has not been given sufficient scientific attention. The objective of thi...

  13. Biomechanical aspects of initial intraosseous stability and implant design: a quantitative micro-morphometric analysis.

    Science.gov (United States)

    Akça, Kivanç; Chang, Ting-Ling; Tekdemir, Ibrahim; Fanuscu, Mete I

    2006-08-01

    The objective of this biomechanical study was to explore the effect of bone micro-morphology on initial intraosseous stability of implants with different designs. Straumann and Astra Tech dental implants were placed into anterior and posterior regions of completely edentulous maxilla and mandible of a human cadaver. Experiments were undertaken to quantify initial implant stability and bone micro-morphology. Installation torque values (ITVs) and implant stability quotients (ISQs) were measured to determine initial intraosseous implant stability. For quantification of relative bone volume and micro-architecture, sectioned implant-bone and bone core specimens of each implant placement site were consecutively scanned and trabecular bone was analyzed in a micro-computed tomography (micro-CT) unit. Experimental outcomes were evaluated for correlations among implant designs, initial intraosseous implant stability and bone micro-structural parameters. ITVs correlated higher with bone volume fraction (BV/TV) than ISQs, at 88.1% and 68.9% levels, respectively. Correlations between ITVs and micro-morphometric parameters were significant at the 95% confidence level (Pimplant designs used were not significant at the 95% confidence level (P>0.05). Bone micro-morphology has a prevailing effect over implant design on intraosseus initial implant stability, and ITV is more sensitive in terms of revealing biomechanical properties at the bone-implant interface in comparison with ISQ.

  14. Oral rehabilitation with dental implants in oligodontia patients

    NARCIS (Netherlands)

    Finnema, KJ; Raghoebar, GM; Meijer, HJA; Vissink, A

    2005-01-01

    Purpose: The aim of this retrospective report was to evaluate the treatment outcome of oral rehabilitation with dental implants in oligodontia patients. Materials and Methods: Thirteen oligodontia patients treated with dental implants were examined clinically and radiographically (follow-up 3 +/- 2

  15. Subgingival Microbiome Colonization and Cytokine Production during Early Dental Implant Healing.

    Science.gov (United States)

    Payne, Jeffrey B; Johnson, Paul G; Kok, Car Reen; Gomes-Neto, João C; Ramer-Tait, Amanda E; Schmid, Marian J; Hutkins, Robert W

    2017-01-01

    Little is known about longitudinal development of the peri-implant subgingival microbiome and cytokine production as a new sulcus forms after dental implant placement. Therefore, the purpose of this observational study was to evaluate simultaneous longitudinal changes in the oral microbiome and cytokine production in the developing peri-implant sulcus compared to control natural teeth. Four and 12 weeks after implant placement and abutment connection, a dental implant and a natural tooth were sampled in 25 patients for subgingival plaque and gingival crevicular fluid (GCF [around teeth] and peri-implant crevicular fluid [PICF] around implants). DNA from plaque samples was extracted and sequenced using Illumina-based 16S rRNA sequencing. GCF and PICF samples were analyzed using a customized Milliplex human cytokine and chemokine magnetic bead panel. Beta diversity analysis revealed that natural teeth and implants had similar subgingival microbiomes, while teeth had greater alpha diversity than implants. At the genus level, however, few differences were noted between teeth and dental implants over 12 weeks. Specifically, Actinomyces and Selenomonas were significantly elevated around teeth versus dental implants at both 4 weeks and 12 weeks, while Corynebacterium and Campylobacter were significantly elevated only at 4 weeks around teeth. The only difference between PICF and GCF biomarkers was significantly elevated granulocyte-macrophage colony-stimulating factor levels around teeth versus dental implants at the 4-week visit. The subgingival microbiome and cytokine production were similar between teeth and implants during early healing, suggesting that these profiles are driven by the patient following dental implant placement and are not determined by anatomical niche. IMPORTANCE Dental implants are a common treatment option offered to patients for tooth replacement. However, little is known regarding initial colonization of the subgingival microbiome and

  16. Usage of demineralized bone powder in dental implant surgery

    International Nuclear Information System (INIS)

    Chang Joon Yim

    1999-01-01

    While there is much concern in the dental community about the risk of disease transfer with processed bone a] iografts, there has never been a case of disease transfer with DFDB. Exclusionary techniques and chemical processing of the allogeneic bone has rendered these grafts safe for human implantation. The literature indicates that there has been considerable interest in the biology and applied science of osteoinduction. The accumulated evidence supports the concept of cartilage and bone cell differentiation induced by a unique bone motphogenetic protein (BMP). Currently clinical usage has been focused on the alveolar bone defects associated with the dental implant surgery, which has become one of the most important areas in dental outpatient clinic. Increased application of the endosseous dental implant system results in a lot of demands to regenerate the alveolar bone defects around the dental implants. Anderegg et al.(1991) reported the excellent results from the combination of DFDB powder and expanded PTFE (polytetrafluorethylene) membranes. Since 1980 the author experienced the human DFDB powders for the oral and maxillofacial surgery and the dental implant surgery. Yim and Kim(1993) evaluated 93 surgical sites where DFDB was used and found 96.7% of success rates at re-entry surgery. Mellonig and Triplett (1993) reported 97% of success rates, and Gelb (1993) obtained 98% of success rates. Fugazzotto (1994) placed 59 dental implants at the time of sinus lifts with the composite graft of DFDB and resorbable tricalcium phosphate and none of implants was lost on uncovering and only one was lost while functioning. Yim (1994) placed 44 dental implants at the time of sinus lifts with DFDB, and none of implants was lost on uncovering. Zinner and Small (1996) placed 215 dental implants at the time of sinus lifts (52 sinuses) with the composite graft of DFDB, and other materials, 3 implants of which were failed on uncovering. To date, maxillary sinus lift graft with

  17. The effect of platelet-rich fibrin on implant stability.

    Science.gov (United States)

    Öncü, Elif; Alaaddinoğlu, E Emine

    2015-01-01

    Achieving accelerated implant osseointegration could make immediate or early loading of implants more predictable. Platelet-rich fibrin (PRF) is frequently used to accelerate soft and hard tissue healing. The activated platelets in PRF release growth factors, resulting in cellular proliferation, collagen synthesis, and osteoid production. The aim of this study was to compare the stability of dental implants inserted in a one-stage surgical protocol with or without PRF application. Twenty healthy patients with adequate alveolar bone and two or more adjacent missing teeth extracted at least 6 months previously were included in this study. A minimum of two tapered implants (Ankylos, Dentsply/Friadent) were placed in each patient. After surgical preparation of the implant sockets, PRF that had been prepared preoperatively was placed randomly into one of the sockets (PRF+). The acellular plasma portion of PRF was used to wet the implant placed into the PRF-coated socket. Resonance frequency measurements were made after implant placement and at 1 week and 1 month postoperatively. Mean implant stability quotients (ISQs) of the PRF+ implants was 69.3 ± 10.5, and mean ISQs for the PRF- implants was 64.5 ± 12.2 at the end of the first week. The mean ISQs at 4 weeks postoperatively were 77.1 ± 7.1 for the PRF+ group and 70.5 ± 7.7 for the PRF- group. In this study, PRF application increased implant stability during the early healing period, as evidenced by higher ISQ values. Simple application of this material seems to provide faster osseointegration.

  18. PEEK with Reinforced Materials and Modifications for Dental Implant Applications

    Directory of Open Access Journals (Sweden)

    Fitria Rahmitasari

    2017-12-01

    Full Text Available Polyetheretherketone (PEEK is a semi-crystalline linear polycyclic thermoplastic that has been proposed as a substitute for metals in biomaterials. PEEK can also be applied to dental implant materials as a superstructure, implant abutment, or implant body. This article summarizes the current research on PEEK applications in dental implants, especially for the improvement of PEEK surface and body modifications. Although various benchmark reports on the reinforcement and surface modifications of PEEK are available, few clinical trials using PEEK for dental implant bodies have been published. Controlled clinical trials, especially for the use of PEEK in implant abutment and implant bodies, are necessary.

  19. Significant improvement of the osseointegration of zirconia dental implants by HS-LEIS analysis

    International Nuclear Information System (INIS)

    Beekmans, H.; Breitenstein, D.; Brongersma, H.H.; Ridder, M. de; Tromp, Th.J.

    2010-01-01

    The use of sintered yttria stabilized zirconia dental implants is a recent development. After initial successes with these new implants a pattern of erratic results emerged. Reliable osseointegration would not always occur. High-sensitivity low energy ion scattering (HS-LEIS) is used to investigate both virgin and rejected implants. The surfaces of the implant are found to be covered with both an organic and inorganic contamination layer. Sterilization does not remove this contamination. Using LEIS as analytic tool a new cleaning process has been developed. Since this cleaning process is in use, the failure rate has dropped to a very low value.

  20. Microcomputed tomography-based assessment of retrieved dental implants

    NARCIS (Netherlands)

    Narra, N.; Antalainen, A.K.; Zipprich, H.; Sándor, G.K.; Wolff, J.

    2015-01-01

    Purpose: The aim of this study was to demonstrate the potential of microcomputed tomography (micro-CT) technology in the assessment of retrieved dental implants. Cases are presented to illustrate the value of micro-CT imaging techniques in determining possible mechanical causes for dental implant

  1. Macro design morphology of endosseous dental implants.

    Science.gov (United States)

    Sahiwal, Indira G; Woody, Ronald D; Benson, Byron W; Guillen, Guillermo E

    2002-05-01

    The identification of dental implant bodies in patients without available records is a considerable problem due to increased patient mobility and to the large number of implant systems with different designs. The purpose of this study was to document the designs of selected implants to help clinicians identify these implants from their radiographic images. More than 50 implant manufacturers were contacted and asked to provide implants with dimensions as close as possible to 3.75 mm (diameter) x 10 mm (length). Forty-four implants were donated, separated into threaded and non-threaded categories, and further sorted into tapered and non-tapered categories. The implants were examined visually, and features on the entire circumference and length of each implant were recorded and categorized as coronal, midbody, or apical. A series of tables describe the 44 implants according to coronal, midbody, and apical features. The results of this project offer dentists basic knowledge of the design of selected dental implants. Such knowledge can aid the radiographic identification of these implants.

  2. Bruxism and Dental Implants: A Meta-Analysis.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Albrektsson, Tomas; Wennerberg, Ann

    2015-10-01

    To test the null hypothesis of no difference in the implant failure rates, postoperative infection, and marginal bone loss after the insertion of dental implants in bruxers compared with the insertion in non-bruxers against the alternative hypothesis of a difference. An electronic search was undertaken in June 2014. Eligibility criteria included clinical studies, either randomized or not. Ten publications were included with a total of 760 implants inserted in bruxers (49 failures; 6.45%) and 2989 in non-bruxers (109 failures; 3.65%). Due to lack of information, meta-analyses for the outcomes "postoperative infection" and "marginal bone loss" were not possible. A risk ratio of 2.93 was found (95% confidence interval, 1.48-5.81; P = 0.002). These results cannot suggest that the insertion of dental implants in bruxers affects the implant failure rates due to a limited number of published studies, all characterized by a low level of specificity, and most of them deal with a limited number of cases without a control group. Therefore, the real effect of bruxing habits on the osseointegration and survival of endosteal dental implants is still not well established.

  3. [Clinical application of individualized three-dimensional printing implant template in multi-tooth dental implantation].

    Science.gov (United States)

    Wang, Lie; Chen, Zhi-Yuan; Liu, Rong; Zeng, Hao

    2017-08-01

    To study the value and satisfaction of three-dimensional printing implant template and conventional implant template in multi-tooth dental implantation. Thirty cases (83 teeth) with missing teeth needing to be implanted were randomly divided into conventional implant template group (CIT group, 15 cases, 42 teeth) and 3D printing implant template group (TDPIT group, 15 cases, 41 teeth). Patients in CIT group were operated by using conventional implant template, while patients in TDPIT group were operated by using three-dimensional printing implant template. The differences of implant neck and tip deviation, implant angle deviation and angle satisfaction between the two groups were compared. The difference of probing depth and bone resorption of implant were compared 1 year after operation between the two groups. The difference of success rate and satisfaction of dental implantation were compared 1 year after operation between the two groups. SPSS19.0 software package was used for statistical analysis. The deviation direction of the neck and the tip in disto-mesial, bucco-palatal, vertical direction and angle of implants in disto-mesial and bucco-palatal direction in TDPIT group were significantly lower than in CIT group (P0.05). The difference of the cumulative success rate in dental implantation at 3 months and 6 months between the two groups were not significant (P>0.05), but the cumulative success rate of TDPIT group was significantly higher than CIT group at 9 months and 1 year (90.48% vs 100%,P=0.043). The patients' satisfaction rate of dental implantation in TDPIT group was significantly higher than in CIT group (86.67% vs 53.33%, P=0.046). Using three-dimensional printing implant template can obtain better accuracy of implant, higher implant success rate and better patients' satisfaction than using conventional implant template. It is suitable for clinical application.

  4. A new testing protocol for zirconia dental implants.

    Science.gov (United States)

    Sanon, Clarisse; Chevalier, Jérôme; Douillard, Thierry; Cattani-Lorente, Maria; Scherrer, Susanne S; Gremillard, Laurent

    2015-01-01

    Based on the current lack of standards concerning zirconia dental implants, we aim at developing a protocol to validate their functionality and safety prior their clinical use. The protocol is designed to account for the specific brittle nature of ceramics and the specific behavior of zirconia in terms of phase transformation. Several types of zirconia dental implants with different surface textures (porous, alveolar, rough) were assessed. The implants were first characterized in their as-received state by Scanning Electron Microscopy (SEM), Focused Ion Beam (FIB), X-Ray Diffraction (XRD). Fracture tests following a method adapted from ISO 14801 were conducted to evaluate their initial mechanical properties. Accelerated aging was performed on the implants, and XRD monoclinic content measured directly at their surface instead of using polished samples as in ISO 13356. The implants were then characterized again after aging. Implants with an alveolar surface presented large defects. The protocol shows that such defects compromise the long-term mechanical properties. Implants with a porous surface exhibited sufficient strength but a significant sensitivity to aging. Even if associated to micro cracking clearly observed by FIB, aging did not decrease mechanical strength of the implants. As each dental implant company has its own process, all zirconia implants may behave differently, even if the starting powder is the same. Especially, surface modifications have a large influence on strength and aging resistance, which is not taken into account by the current standards. Protocols adapted from this work could be useful. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  5. Comparing Short Dental Implants to Standard Dental Implants: Protocol for a Systematic Review.

    Science.gov (United States)

    Rokn, Amir Reza; Keshtkar, Abbasali; Monzavi, Abbas; Hashemi, Kazem; Bitaraf, Tahereh

    2018-01-18

    Short dental implants have been proposed as a simpler, cheaper, and faster alternative for the rehabilitation of atrophic edentulous areas to avoid the disadvantages of surgical techniques for increasing bone volume. This review will compare short implants (4 to 8 mm) to standard implants (larger than 8 mm) in edentulous jaws, evaluating on the basis of marginal bone loss (MBL), survival rate, complications, and prosthesis failure. We will electronically search for randomized controlled trials comparing short dental implants to standard dental implants in the following databases: PubMed, Web of Science, EMBASE, Scopus, the Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov with English language restrictions. We will manually search the reference lists of relevant reviews and the included articles in this review. The following journals will also be searched: European Journal of Oral Implantology, Clinical Oral Implants Research, and Clinical Implant Dentistry and Related Research. Two reviewers will independently perform the study selection, data extraction and quality assessment (using the Cochrane Collaboration tool) of included studies. All meta-analysis procedures including appropriate effect size combination, sub-group analysis, meta-regression, assessing publication or reporting bias will be performed using Stata (Statacorp, TEXAS) version 12.1. Short implant effectiveness will be assessed using the mean difference of MBL in terms of weighted mean difference (WMD) and standardized mean difference (SMD) using Cohen's method. The combined effect size measures in addition to the related 95% confidence intervals will be estimated by a fixed effect model. The heterogeneity of the related effect size will be assessed using a Q Cochrane test and I2 measure. The MBL will be presented by a standardized mean difference with a 95% confidence interval. The survival rate of implants, prostheses failures, and complications will be reported using a risk

  6. Intricate Assessment and Evaluation of Effect of Bruxism on Long-term Survival and Failure of Dental Implants: A Comparative Study.

    Science.gov (United States)

    Yadav, Kajal; Nagpal, Abhishek; Agarwal, S K; Kochhar, Aarti

    2016-08-01

    affected by bruxism. Special attention is required in such patients while doing treatment planning. For the long-term clinical success and survival of dental implants in patients, special emphasis should be given on the patient's deleterious oral habits, such as bruxism as in long run, they influence the stability of dental implants.

  7. Novel surface coating materials for endodontic dental implant

    International Nuclear Information System (INIS)

    Fathi, M.H.; Mortazavi, V.; Moosavi, S.B.

    2003-01-01

    The aim of this study was to design and produce novel coating materials in order to obtain two goals including; improvement of the corrosion behavior of metallic dental endodontic implant and the bone osteointegration simultaneously. Stainless steel 316L (SS) was used as a metallic substrate and a novel Hydroxyapatite/Titanium (HA/Ti) composite coating was prepared on it. Structural characterization techniques including XRD, SEM and EDX were utilized to investigate the microstructure and morphology of the coating. Electrochemical tests were performed in physiological solutions in order to determine and compare the corrosion behavior of the coated and uncoated specimens as an indication of biocompatibility. Two types of endodontic implants including; SS with and without (HA/Ti) composite coating were prepared and subsequently implanted in the mandibular canine of 20 cats after completion of root canal treatment and osseous preparation. After a healing period of 4 months, osteointegration evaluation and histopathological interpretation was carried out using SEM and optical microscopy. Results indicate that the novel HA/Ti composite coating improves the corrosion behavior and biocompatibility of SS endodontic dental implant. The clinical evaluation (in vivo test) results showed that there was significant difference in osteointegration between coated and uncoated endodontic dental implants and average bone osteointegration of coated implants were more than uncoated implants. The histopathological results and bone tissue response to the coated implants was acceptable and it was concluded that HA/Ti composite coated SS could be used as well as an endodontic dental implant. (author)

  8. A study on setting of the fatigue limit of temporary dental implants.

    Science.gov (United States)

    Kim, M H; Cho, E J; Lee, J W; Kim, E K; Yoo, S H; Park, C W

    2017-07-01

    A temporary dental implant is a medical device which is temporarily used to support a prosthesis such as an artificial tooth used for restoring patient's masticatory function during implant treatment. It is implanted in the oral cavity to substitute for the role of tooth. Due to the aging and westernization of current Korean society, the number of tooth extraction and implantation procedures is increasing, leading to an increase in the use and development of temporary dental implants. Because an implant performs a masticatory function in place of a tooth, a dynamic load is repeatedly put on the implant. Thus, the fatigue of implants is reported to be the most common causes of the fracture thereof. According to the investigation and analysis of the current domestic and international standards, the standard for fatigue of implant fixtures is not separately specified. Although a test method for measuring the fatigue is suggested in an ISO standard, it is a standard for permanent dental implants. Most of the test standards for Korean manufacturers and importers apply 250 N or more based on the guidance for the safety and performance evaluation of dental implants. Therefore, this study is intended to figure out the fatigue standard which can be applied to temporary dental implants when measuring the fatigue according to the test method suggested in the permanent dental implant standard. The results determined that suitable fatigue standards of temporary dental implants should be provided by each manufacturer rather than applying 250 N. This study will be useful for the establishment of the fatigue standards and fatigue test methods of the manufacturers and importers of temporary dental implants.

  9. Osseointegration of dental implants in Macaca fascicularis

    Science.gov (United States)

    Dewi, R. S.; Odang, R. W.; Odelia, L.

    2017-08-01

    Osseointegration is an important factor in determining the success of a dental implant. It can be assessed from the osseointegration that occurs between the implant and the bone. The implant stability is determined by the osseous support at the implant-bone interface, which is commonly evaluated by histomorphometric analysis. This study aimed to evaluate whether the osseointegration level measured by a Low Resonance Frequency Analyzer (LRFA) gave results as good as those obtained by histomorphometric examination. Six male Macaca fascicularis were used in this study. In each animal, two types of loading were performed: immediate and delayed loading. Clinical examination and LRFA measurement were performed to determine osseointegration at the first and second weeks and at the first, second, third, and fourth months. After four months, histomorphometric examination was performed. The relationship between the histomorphometric examination and LRFA measurement was compared using the Pearson correlation coefficient. There was no significant difference in the osseointegration between immediate loading and delayed loading (p > 0.05) The bone-implant contact percentage in the first group did not differ significantly from that in the second group. Statistical analysis showed that there was a strong correlation between LRFA measurement and histomorphometric examination. Osseointegration could be evaluated through LRFA measurement as well as through histomorphometric examination.

  10. Cytocompatibility, cytotoxicity and genotoxicity analysis of dental implants

    Science.gov (United States)

    Reigosa, M.; Labarta, V.; Molinari, G.; Bernales, D.

    2007-11-01

    Several types of materials are frequently used for dental prostheses in dental medicine. Different treatments with titanium are the most used. The aim of the present study was to analyze by means of cytotoxicity and cytocompatibility techniques the capacity of dental implants to integrate to the bone tissue. Cultures of UMR 106 cell line derived from an osteosarcoma were used for bioassays mainly because they show many of the properties of osteoblasts. Dental implant samples provided by B&W company were compared with others of recognized trademarks. The first ones contain ASTM titanium (8348 GR2) with acid printing. Cytotoxicity was analyzed by means of lysosome activity, using the neutral red technique and alkaline phosphatase enzyme activity. Cell variability was determined by means of the acridine ethidium-orange bromide technique. One-way ANOVA and Bonferroni and Duncan post-ANOVA tests were used for the statistical analysis. The assays did not show significant differences among the dental implants analyzed. Our findings show that the dental prostheses studied present high biocompatibility, quantified by the bioassays performed. The techniques employed revealed that they can be a useful tool for the analysis of other materials for dental medicine use.

  11. Cytocompatibility, cytotoxicity and genotoxicity analysis of dental implants

    International Nuclear Information System (INIS)

    M, Reigosa; V, Labarta; G, Molinari; D, Bernales

    2007-01-01

    Several types of materials are frequently used for dental prostheses in dental medicine. Different treatments with titanium are the most used. The aim of the present study was to analyze by means of cytotoxicity and cytocompatibility techniques the capacity of dental implants to integrate to the bone tissue. Cultures of UMR 106 cell line derived from an osteosarcoma were used for bioassays mainly because they show many of the properties of osteoblasts. Dental implant samples provided by B and W company were compared with others of recognized trademarks. The first ones contain ASTM titanium (8348 GR2) with acid printing. Cytotoxicity was analyzed by means of lysosome activity, using the neutral red technique and alkaline phosphatase enzyme activity. Cell variability was determined by means of the acridine ethidium-orange bromide technique. One-way ANOVA and Bonferroni and Duncan post-ANOVA tests were used for the statistical analysis. The assays did not show significant differences among the dental implants analyzed. Our findings show that the dental prostheses studied present high biocompatibility, quantified by the bioassays performed. The techniques employed revealed that they can be a useful tool for the analysis of other materials for dental medicine use

  12. Evaluation of primary stability of self-tapping and non-self-tapping dental implants. A 12-week clinical study.

    Science.gov (United States)

    Marković, Aleksa; Calvo-Guirado, José Luís; Lazić, Zoran; Gómez-Moreno, Gerardo; Ćalasan, Dejan; Guardia, Javier; Čolic, Snježana; Aguilar-Salvatierra, Antonio; Gačić, Bojan; Delgado-Ruiz, Rafael; Janjić, Bojan; Mišić, Tijana

    2013-06-01

    The aim of this study was to investigate the relationship between surgical techniques and implant macro-design (self-tapping/non-self-tapping) for the optimization of implant stability in the low-density bone present in the posterior maxilla using resonance frequency analysis (RFA). A total of 102 implants were studied. Fifty-six self-tapping BlueSkyBredent® (Bredent GmbH&Co.Kg®, Senden, Germany) and 56 non-self-tapping Standard Plus Straumann® (Institut Straumann AG®, Waldenburg, Switzerland) were placed in the posterior segment of the maxilla. Implants of both types were placed in sites prepared with either lateral bone-condensing or with bone-drilling techniques. Implant stability measurements were performed using RFA immediately after implant placement and weekly during a 12-week follow-up period. Both types of implants placed after bone condensing achieved significantly higher stability immediately after surgery, as well as during the entire 12-week observation period compared with those placed following bone drilling. After bone condensation, there were no significant differences in primary stability or in implant stability after the first week between both implant types. From 2 to 12 postoperative weeks, significantly higher stability was shown by self-tapping implants. After bone drilling, self-tapping implants achieved significantly higher stability than non-self-tapping implants during the entire follow-up period. The outcomes of the present study indicate that bone drilling is not an effective technique for improving implant stability and, following this technique, the use of self-tapping implants is highly recommended. Implant stability optimization in the soft bone can be achieved by lateral bone-condensing technique, regardless of implant macro-design. © 2011 Wiley Periodicals, Inc.

  13. Dental implant surgery: planning and guidance

    International Nuclear Information System (INIS)

    Lobregt, S.; Schillings, J.J.; Vuurberg, E.

    2001-01-01

    A prototype application has been developed for interactive planning of dental implants on the EasyVision workstation. The user is led step by step via virtual positioning of the implant to the design of a customized drill guide. (orig.)

  14. A case of peri-implantitis and osteoradionecrosis arising around dental implants placed before radiation therapy

    OpenAIRE

    Teramoto, Yuji; Kurita, Hiroshi; Kamata, Takahiro; Aizawa, Hitoshi; Yoshimura, Nobuhiko; Nishimaki, Humihiro; Takamizawa, Kazunobu

    2016-01-01

    A little is known about the effect of radiotherapy on the dental implants that have previously been osseointegrated and charged. Here, we reported a case of osteoradionecrosis which arose around dental implants placed before radiation therapy.

  15. Medicolegal implications of dental implant therapy.

    Science.gov (United States)

    Rees, Jonathan

    2013-04-01

    Despite the recent economic downturn, the dental implant market continues to grow year on year. Many more dentists are involved in the placement restoration of dental implants and dental implants are being placed in an extended range of clinical scenarios. Dental implant therapy remains a high risk area for the inexperienced interns of civil negligence claims and General Dental Council hearings. Risk can be mitigated by:• Ensuring appropriate indemnity • Complying with the published requirements for training • Maintaining detailed and extensive clinical records • Completing the initial phases of history, examination and investigations robustly • Recording a diagnosis • Providing a bespoke written treatment plan that includes details of the need for treatment, the treatment options (the risks and benefits), the phases of treatment, the costs of treatment,the expected normal sequelae of surgery, the risks and complications of implant therapy and the requirement for future maintenance. The provision of treatment that is different in nature or extent to that agreed can result in a breach of contract as well as a claim for negligence • Engaging sufficiently with the patient to obtain consent • Providing written postoperative instructions detailing emergency arrangements, patients who are anxious or in pain may not retain oral information • Making a frank disclosure of complication or collateral damage • Considering referral at an early stage particularly if reparative surgery is required. The stress of complications or failure may impair a dentist's normally sound judgement; there may be financial pressure, or concerns regarding reputation. In some cases, dentists avoid making a frank disclosure, feel obliged to undertake complicated reparative surgery, fail to make a timely referral, fail to respond appropriately to patient's concerns and in some cases attempt to alter the clinical records.However, in the best of hands and without negligence

  16. Prevalence of Dental Implants and Evaluation of Peri-implant Bone Levels in Patients Presenting to a Dental School: A Radiographic Cross-Sectional 2-Year Study.

    Science.gov (United States)

    Alkan, Eylem Ayhan; Mau, Lian Ping; Schoolfield, John; Guest, Gary F; Cochran, David L

    To evaluate the number of patients with dental implants who present to a dental school clinic for screening and to report the prevalence of peri-implant bone level change detected on digital panoramic radiographs of those subjects. Patient screening files for 9,422 patients over a 2-year period were examined to see how many patients presented with dental implants. Those patients with at least one implant were further evaluated by measuring the bone level on the mesial and distal sides of the implant using the screening radiograph. A total of 187 patients (2%) had at least one implant. In regard to implants, 423 were examined and 146 (33%) had no detectable bone loss defined as bone level below the top of the implant. When thresholds of bone loss were evaluated, 109 implants (25%) had ≥ 2 mm of bone loss on either the mesial or distal sides or both. The median bone loss was 1.74 mm for the 277 implants with detectable bone loss and 2.97 mm for the 109 implants that had ≥ 2 mm bone loss. Interestingly, patients who were ≥ 70 years of age had significantly (P = .03) more bone loss in the mandible compared with the maxilla, while patients who were 60 to 69 years of age had significantly greater loss in the maxilla. These data reveal that for patients presenting to the dental school for a screening over a 2-year period, 1.98% had one or more dental implants. Furthermore, those patients with implants had a minimum amount of bone loss as measured from the top of the implant.

  17. Surgical templates for dental implant positioning; current knowledge and clinical perspectives

    Directory of Open Access Journals (Sweden)

    Mohammed Zaheer Kola

    2015-01-01

    Full Text Available Dental implants have been used in a variety of different forms for many years. Since the mid-20 th century, there has been an increase in interest in the implant process for the replacement of missing teeth. Branemark was one of the initial pioneers who applied scientifically based research techniques to develop an endosseous implant that forms an immobile connection with bone. The need for a dental implant to completely address multiple physical and biological factors imposes tremendous constraints on the surgical and handling protocol. Metallic dental implants have been successfully used for decades, but they have serious shortcomings related to their bony union and the fact that their mechanical properties do not match those of bone. However, anatomic limitation and restorative demands encourage the surgeon to gain precision in planning and surgical positioning of dental implants. Ideal placement of the implant facilitates the establishment of favorable forces on the implants and the prosthetic component as well as ensures an aesthetic outcome. Therefore, it is advisable to establish a logical continuity between the planned restoration and the surgical phases, it is essential to use a transfer device that for sure increases the predictability of success. The surgical guide template is fabricated by a dental technician after the presurgical restorative appointments that primarily include determination of occlusal scheme and implant angulations. Here, authors genuinely attempted to review the evolution and clinical applicability of surgical templates used in the placement of dental implants.

  18. Ag-plasma modification enhances bone apposition around titanium dental implants: an animal study in Labrador dogs

    Directory of Open Access Journals (Sweden)

    Qiao SC

    2015-01-01

    Full Text Available Shichong Qiao,1,* Huiliang Cao,2,* Xu Zhao,1,* Hueiwen Lo,1 Longfei Zhuang,1 Yingxin Gu,1 Junyu Shi,1 Xuanyong Liu,2 Hongchang Lai1 1Department of Oral and Maxillofacial Implantology, Shanghai Key Laboratory of Stomatology, Shanghai Ninth People’s Hospital, School of Medicine, Shanghai Jiao Tong University, 2State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, People’s Republic of China *These authors contributed equally to this work Abstract: Dental implants with proper antibacterial ability as well as ideal osseointegration are being actively pursued. The antimicrobial ability of titanium implants can be significantly enhanced via modification with silver nanoparticles (Ag NPs. However, the high mobility of Ag NPs results in their potential cytotoxicity. The silver plasma immersion ion-implantation (Ag-PIII technique may remedy the defect. Accordingly, Ag-PIII technique was employed in this study in an attempt to reduce the mobility of Ag NPs and enhance osseointegration of sandblasted and acid-etched (SLA dental implants. Briefly, 48 dental implants, divided equally into one control and three test groups (further treated by Ag-PIII technique with three different implantation parameters, were inserted in the mandibles of six Labrador dogs. Scanning electron microscopy, X-ray photoelectron spectroscopy, and inductively coupled plasma optical emission spectrometry were used to investigate the surface topography, chemical states, and silver release of SLA- and Ag-PIII-treated titanium dental implants. The implant stability quotient examination, Microcomputed tomography evaluation, histological observations, and histomorphometric analysis were performed to assess the osseointegration effect in vivo. The results demonstrated that normal soft tissue healing around dental implants was observed in all the groups, whereas the implant stability

  19. Dental CT and orthodontic implants: imaging technique and assessment of available bone volume in the hard palate

    Energy Technology Data Exchange (ETDEWEB)

    Gahleitner, Andre E-mail: andre.gahleitner@univie.ac.at; Podesser, Birgit; Schick, Susanne; Watzek, Georg; Imhof, Herwig

    2004-09-01

    Purpose: Palatal implants (PI) have been introduced for orthodontic treatment of dental and skeletal dysgnathia. Due to the restricted amount of bone in this region, precise preoperative anatomic information is necessary. The aim of this study was to determine whether dental CT could serve as a tool to locate the optimal size and position for orthodontic implant placement. Materials and methods: In 32 patients, where palatal implant placement was planned, axial CT scans of the maxillary bone were acquired. Using a standard dental software package (Easy Vision dental software package 2.1, Philips; Best, The Netherlands), paracoronal views were reconstructed and measurements of palatal bone height in 3 mm increments, dorsally from the incisive canal, were performed in the median and both paramedian regions. Results: The overall mean bone height was 5.01 mm (S.D. 2.60), ranging from 0 to 16.9 mm. The maximum palatal bone height was 6.17 mm (S.D. 2.81) at 6 mm dorsally from the incisive canal. Due to the lack of adequate bone (less than 4 mm), implant placement was not performed in 3 cases (7%). In the remaining 39 cases (93.0%), primary implant stability was achieved and complications, such as perforation of the palate, could be avoided. Conclusion: The results demonstrate that dental CT promises to be a valuable tool in evaluating the potential and optimal size and site for orthodontic implant placement.

  20. Dental CT and orthodontic implants: imaging technique and assessment of available bone volume in the hard palate

    International Nuclear Information System (INIS)

    Gahleitner, Andre; Podesser, Birgit; Schick, Susanne; Watzek, Georg; Imhof, Herwig

    2004-01-01

    Purpose: Palatal implants (PI) have been introduced for orthodontic treatment of dental and skeletal dysgnathia. Due to the restricted amount of bone in this region, precise preoperative anatomic information is necessary. The aim of this study was to determine whether dental CT could serve as a tool to locate the optimal size and position for orthodontic implant placement. Materials and methods: In 32 patients, where palatal implant placement was planned, axial CT scans of the maxillary bone were acquired. Using a standard dental software package (Easy Vision dental software package 2.1, Philips; Best, The Netherlands), paracoronal views were reconstructed and measurements of palatal bone height in 3 mm increments, dorsally from the incisive canal, were performed in the median and both paramedian regions. Results: The overall mean bone height was 5.01 mm (S.D. 2.60), ranging from 0 to 16.9 mm. The maximum palatal bone height was 6.17 mm (S.D. 2.81) at 6 mm dorsally from the incisive canal. Due to the lack of adequate bone (less than 4 mm), implant placement was not performed in 3 cases (7%). In the remaining 39 cases (93.0%), primary implant stability was achieved and complications, such as perforation of the palate, could be avoided. Conclusion: The results demonstrate that dental CT promises to be a valuable tool in evaluating the potential and optimal size and site for orthodontic implant placement

  1. Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study

    Science.gov (United States)

    AUNMEUNGTONG, W.; KHONGKHUNTHIAN, P.; RUNGSIYAKULL, P.

    2016-01-01

    SUMMARY Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Materials and methods Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. Results There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Conclusions Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Clinical implications Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant

  2. Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study.

    Science.gov (United States)

    Aunmeungtong, W; Khongkhunthian, P; Rungsiyakull, P

    2016-01-01

    Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force.

  3. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    OpenAIRE

    Sanjay Byakodi; Sachin Kumar; Rajesh Kumar Reddy; Vipin Kumar; Shipra Sepolia; Shivangi Gupta; Harkanwal Preet Singh

    2017-01-01

    Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental i...

  4. The relationship between panoramic indices and dental implant failure

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hyun Jung; Yi, Won Jin; Heo, Min Suk; Lee, Jin Koo; Lee, Sam Sun; Choi, Soon Chul [Seoul National University College of Medicine, Seoul (Korea, Republic of); An, Chang Hyeon [Kyungpook National University College of Medicine, Taegu (Korea, Republic of)

    2004-03-15

    Several panoramic indices have been suggested to assess bone quality from the morphology and width of mandibular cortex on panoramic radiography. The purpose of this study was to compare dental implant failure group with control group in panoramic mandibular index (PMI), mandibular cortical index (MCI), and gonion index (GI) and to determine the effect of these panoramic indices on dental implant failure. A case-control study was designed. Test group (n = 42) consisted of the patients who had their implants extracted because of peri-implantitis. Control group (n = 139) consisted of the patients who retained their implants over one year without any pathologic changes and had been followed up periodically. They had dental implants installed in their mandibles without bone augmentation surgery from 1991 to 2001. The following measures were collected for each patients: 1) PMI, MCI, and GI were measured twice at one-week interval on preoperative panoramic views; and 2) age, sex, implant length, implant type, installed location, occluding dentition state, and complication were investigated from the chart record. The PMI showed moderate level of repeatability. The intra-observer agreement of MCI and GI were good. There was statistically significant difference in PMI between two groups. There were significant different patterns of distribution of MCI and GI between two groups. Among the panoramic indices, PMI and MCI showed significant correlation with dental implant failure. Panoramic indices can be used as reference data in estimating bone quality of edentulous patients who are to have implants installed in their mandibles.

  5. The relationship between panoramic indices and dental implant failure

    International Nuclear Information System (INIS)

    Cho, Hyun Jung; Yi, Won Jin; Heo, Min Suk; Lee, Jin Koo; Lee, Sam Sun; Choi, Soon Chul; An, Chang Hyeon

    2004-01-01

    Several panoramic indices have been suggested to assess bone quality from the morphology and width of mandibular cortex on panoramic radiography. The purpose of this study was to compare dental implant failure group with control group in panoramic mandibular index (PMI), mandibular cortical index (MCI), and gonion index (GI) and to determine the effect of these panoramic indices on dental implant failure. A case-control study was designed. Test group (n = 42) consisted of the patients who had their implants extracted because of peri-implantitis. Control group (n = 139) consisted of the patients who retained their implants over one year without any pathologic changes and had been followed up periodically. They had dental implants installed in their mandibles without bone augmentation surgery from 1991 to 2001. The following measures were collected for each patients: 1) PMI, MCI, and GI were measured twice at one-week interval on preoperative panoramic views; and 2) age, sex, implant length, implant type, installed location, occluding dentition state, and complication were investigated from the chart record. The PMI showed moderate level of repeatability. The intra-observer agreement of MCI and GI were good. There was statistically significant difference in PMI between two groups. There were significant different patterns of distribution of MCI and GI between two groups. Among the panoramic indices, PMI and MCI showed significant correlation with dental implant failure. Panoramic indices can be used as reference data in estimating bone quality of edentulous patients who are to have implants installed in their mandibles.

  6. Fracture of Reduced-Diameter Zirconia Dental Implants Following Repeated Insertion.

    Science.gov (United States)

    Karl, Matthias; Scherg, Stefan; Grobecker-Karl, Tanja

    Achievement of high insertion torque values indicating good primary stability is a goal during dental implant placement. The objective of this study was to evaluate whether or not two-piece implants made from zirconia ceramic may be damaged as a result of torque application. A total of 10 two-piece zirconia implants were repeatedly inserted into polyurethane foam material with increasing density and decreasing osteotomy size. The insertion torque applied was measured, and implants were checked for fractures by applying the fluorescent penetrant method. Weibull probability of failure was calculated based on the recorded insertion torque values. Catastrophic failures could be seen in five of the implants from two different batches at insertion torques ranging from 46.0 to 70.5 Ncm, while the remaining implants (all belonging to one batch) survived. Weibull probability of failure seems to be low at the manufacturer-recommended maximum insertion torque of 35 Ncm. Chipping fractures at the thread tips as well as tool marks were the only otherwise observed irregularities. While high insertion torques may be desirable for immediate loading protocols, zirconia implants may fracture when manufacturer-recommended insertion torques are exceeded. Evaluating bone quality prior to implant insertion may be useful.

  7. Dental implants: A boon to dentistry

    Directory of Open Access Journals (Sweden)

    B H Sripathi Rao

    2015-01-01

    Full Text Available The development and use of implants is one of the biggest advances in dentistry in the last few decades. It has helped to give many solutions to tooth loss as well as maxillo facial prosthetics. This article traces the history and evolution of dental implants.

  8. LOCAL COMPLICATIONS OCCURRING DURING DENTAL IMPLANTATION

    Directory of Open Access Journals (Sweden)

    Tihomir Georgiev

    2010-11-01

    Full Text Available With regard to the emergence of new concepts in dental treatment involving placement of dental implants and the significance of therapeutic treatment of the intrusion in their complications. The purpose of the article is to make a review of the problems and to point out options for their treatment.

  9. Atypical Case of Three Dental Implants Displaced into the Maxillary Sinus

    Directory of Open Access Journals (Sweden)

    João Felipe Bonatto Bruniera

    2015-01-01

    Full Text Available Oral rehabilitation with dental implants has become a routine treatment in contemporary dentistry. The displacement of dental implants into the sinus membrane, a complication related to the maxillary sinus, is one of the most common accidents reported in the literature. The treatment for this complication is the surgical removal of the implant. A 60-year-old woman with three dental implants displaced into the maxillary sinus (one implant displaced into the left maxillary sinus and two implants displaced into the right maxillary sinus underwent surgery for removal of the implants. The surgery to remove the implants was performed under local anesthesia through the Caldwell-Luc technique. The patient was subsequently administered antibiotic, anti-inflammatory, and analgesic drugs. The patient returned 7 days after the surgery for suture removal and is being regularly monitored to determine whether future rehabilitation of the edentulous area is necessary. In conclusion, surgical removal of the dental implant displaced into the maxillary sinus is the treatment of choice. This technique is appropriate because it allows the use of local anesthesia and provides direct visualization for the removal of the implants.

  10. Identificación radiográfica de implantes dentales

    OpenAIRE

    Insua Brandariz, Ángel

    2012-01-01

    La identificación de implantes dentales en pacientes sin registros clínicos representa un problema importante y creciente debido a la movilidad de la población, al incremento del número de implantes colocados, así como al aumento del número de diseños y sistemas de implantes. Objetivos 1. Crear la primera base de datos donde se describan las características morfo-radiográficas de todos los tipos de implantes dentales. 2. Identificar morfológica y radiográficamente los implan...

  11. Engineered Protein Coatings to Improve the Osseointegration of Dental and Orthopaedic Implants

    Science.gov (United States)

    Raphel, Jordan; Karlsson, Johan; Galli, Silvia; Wennerberg, Ann; Lindsay, Christopher; Haugh, Matthew; Pajarinen, Jukka; Goodman, Stuart B.; Jimbo, Ryo; Andersson, Martin; Heilshorn, Sarah C.

    2016-01-01

    Here we present the design of an engineered, elastin-like protein (ELP) that is chemically modified to enable stable coatings on the surfaces of titanium-based dental and orthopaedic implants by novel photocrosslinking and solution processing steps. The ELP includes an extended RGD sequence to confer bio-signaling and an elastin-like sequence for mechanical stability. ELP thin films were fabricated on cp-Ti and Ti6Al4V surfaces using scalable spin and dip coating processes with photoactive covalent crosslinking through a carbene insertion mechanism. The coatings withstood procedures mimicking dental screw and hip replacement stem implantations, a key metric for clinical translation. They promoted rapid adhesion of MG63 osteoblast-like cells, with over 80% adhesion after 24 hours, compared to 38% adhesion on uncoated Ti6Al4V. MG63 cells produced significantly more mineralization on ELP coatings compared to uncoated Ti6Al4V. Human bone marrow mesenchymal stem cells (hMSCs) had an earlier increase in alkaline phosphatase activity, indicating more rapid osteogenic differentiation and mineral deposition on adhesive ELP coatings. Rat tibia and femur in vivo studies demonstrated that cell-adhesive ELP-coated implants increased bone-implant contact area and interfacial strength after one week. These results suggest that ELP coatings withstand surgical implantation and promote rapid osseointegration, enabling earlier implant loading and potentially preventing micromotion that leads to aseptic loosening and premature implant failure. PMID:26790146

  12. Research on dental implant and its industrialization stage

    Science.gov (United States)

    Dongjoon, Yang; Sukyoung, Kim

    2017-02-01

    Bone cell attachment to Ti implant surfaces is the most concerned issue in the clinical implant dentistry. Many attempts to achieve the fast and strong integration between bone and implant have been tried in many ways, such as selection of materials (for example, Ti, ZrO2), shape design of implant (for example, soft tissue level, bone level, taped or conical, etc), and surface modification of implants (for example, roughed. coated, hybrid), etc. Among them, a major consideration is the surface design of dental implants. The surface with proper structural characteristics promotes or induces the desirable responses of cells and tissues. To obtain such surface which has desirable cell and tissue response, a variety of surface modification techniques has been developed and employed for many years. In this review, the method and trend of surface modification will be introduced and explained in terms of the surface topography and chemistry of dental implants.

  13. Oral Rehabilitation With Orthognathic Surgery After Dental Implant Placement for Class III Malocclusion With Skeletal Asymmetry and Posterior Bite Collapse.

    Science.gov (United States)

    Ohba, Seigo; Nakatani, Yuya; Kawasaki, Takako; Tajima, Nobutaka; Tobita, Takayoshi; Yoshida, Noriaki; Sawase, Takashi; Asahina, Izumi

    2015-08-01

    Increasing numbers of older patients are seeking orthognathic surgery to treat jaw deformity. However, orthodontic and orthognathic surgical treatment is difficult in cases without occlusal vertical stop. A 55-year-old man presented with Class III malocclusion and mandibular protrusion including esthetic problems and posterior bite collapse. He underwent dental implant treatment to reconstruct an occlusal vertical stop before orthognathic surgery. His occlusal function and esthetic problems improved after surgery, and his skeletal and occlusal stability has been maintained for 6 years. Dental implant placement at appropriate positions could help to determine the position of the proximal segment at orthognathic surgery and could shorten the time required to restore esthetic and occlusal function. This case demonstrates how skeletal and dental stability can be maintained long after surgery in a patient with jaw deformity and posterior bite collapse.

  14. Decoronation followed by dental implants placement: fundamentals, applications and explanations

    Science.gov (United States)

    Consolaro, Alberto; Ribeiro, Paulo Domingos; Cardoso, Maurício A.; Miranda, Dario A. Oliveira; Salfatis, Monica

    2018-01-01

    ABSTRACT Dental arches areas with teeth presenting dentoalveolar ankylosis and replacement root resorption can be considered as presenting normal bone, in full physiological remodeling process; and osseointegrated implants can be successfully placed. Bone remodeling will promote osseointegration, regardless of presenting ankylosis and/or replacement root resorption. After 1 to 10 years, all dental tissues will have been replaced by bone. The site, angulation and ideal positioning in the space to place the implant should be dictated exclusively by the clinical convenience, associated with previous planning. One of the advantages of decoronation followed by dental implants placement in ankylosed teeth with replacement resorption is the maintenance of bone volume in the region, both vertical and horizontal. If possible, the buccal part of the root, even if thin, should be preserved in the preparation of the cavity for the implant, as this will maintain gingival tissues looking fully normal for long periods. In the selection of cases for decoronation, the absence of microbial contamination in the region - represented by chronic periapical lesions, presence of fistula, old unconsolidated root fractures and active advanced periodontal disease - is important. Such situations are contraindications to decoronation. However, the occurrence of dentoalveolar ankylosis and replacement resorption without contamination should neither change the planning for implant installation, nor the criteria for choosing the type and brand of dental implant to be used. Failure to decoronate and use dental implants has never been reported. PMID:29791693

  15. Evaluating the Effectiveness of Biomaterial Removal from Dental Implant Drills

    Science.gov (United States)

    2016-06-13

    dental implant drills. More research is indicated to differentiate surgical debris from solution remnants, to verify results with different cleaning...In the past 50 years, research studies evaluating the effectiveness of cleaning dental instruments focused primarily on endodontic files and dental...of 1.64 implants per visit (T Oringderff, oral communication, APR 2016); combined with the additional use of a starter drill and the possible use

  16. Systemic Assessment of Patients Undergoing Dental Implant Surgeries: A Trans- and Post-operative Analysis.

    Science.gov (United States)

    Byakodi, Sanjay; Kumar, Sachin; Reddy, Rajesh Kumar; Kumar, Vipin; Sepolia, Shipra; Gupta, Shivangi; Singh, Harkanwal Preet

    2017-01-01

    Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI) questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1) absolutely not, (2) slightly, (3) somewhat, or (4) very much. All the results were recorded and statistical analyzed by SPSS software. Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality ( n = 38). Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla ( P < 0.001). The difference of average STAI-State subscore before and after the surgery was statistically significant ( P < 0.05; significant). Mandibular dental implants show more clamping (torque) than maxillary dental implants.

  17. Systemic assessment of patients undergoing dental implant surgeries: A trans- and post-operative analysis

    Directory of Open Access Journals (Sweden)

    Sanjay Byakodi

    2017-01-01

    Full Text Available Background: Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Materials and Methods: Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1 absolutely not, (2 slightly, (3 somewhat, or (4 very much. All the results were recorded and statistical analyzed by SPSS software. Results: Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality (n = 38. Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla (P < 0.001. The difference of average STAI-State subscore before and after the surgery was statistically significant (P < 0.05; significant. Conclusion: Mandibular dental implants show more clamping (torque than maxillary

  18. Dental Implants in the Elderly Population: A Long-Term Follow-up.

    Science.gov (United States)

    Compton, Sharon M; Clark, Danielle; Chan, Stephanie; Kuc, Iris; Wubie, Berhanu A; Levin, Liran

    The objectives of this study were to evaluate implant survival and success in the elderly population and to assess indicators and risk factors for success or failure of dental implants in older adults (aged 60 years and older). This historical prospective study was developed from a cohort of patients born prior to 1950 who received dental implants in a single private dental office. Implant survival and marginal bone levels were recorded and analyzed with regard to different patient- and implant-related factors. The study examined 245 patient charts and 1,256 implants from one dental clinic. The mean age at the time of implant placement was 62.18 ± 8.6 years. Smoking was reported by 9.4% of the cohort studied. The overall survival rate of the implants was 92.9%; 7.1% of the implants had failed. Marginal bone loss depicted by exposed threads was evident in 23.3% of the implants. Presenting with generalized periodontal disease and/or severe periodontal disease negatively influenced the survival probability of the implant. Implants placed in areas where bone augmentation was performed prior to or during implant surgery did not have the same longevity compared with those that did not have augmentation prior to implantation. The overall findings concluded that implants can be successfully placed in older adults. A variety of factors are involved in the long-term success of the implant, and special consideration should be taken prior to placing implants in older adults to limit the influence of those risk factors.

  19. Osteomyelitis of the Mandible after Dental Implants in an Immunocompetent Patient

    Directory of Open Access Journals (Sweden)

    Matthieu Balanger

    2017-01-01

    Full Text Available Dental implants are now broadly used to replace missing teeth, and the presence of infectious complications is rising. Dental implant therapy as a local risk factor for the onset of osteomyelitis and its management have not been widely explored. Here, we report an unusual case of mandibular suppurative osteomyelitis caused by Streptococcus intermedius in a healthy and immunocompetent patient secondary to mandibular implants. We describe how surgery combined with systemic application of antibiotics allowed conservation of the dental implants in the mandibular bone, discuss the probable source of contamination, and present the follow-up of the osteomyelitis.

  20. Dental Implants in an Aged Population: Evaluation of Periodontal Health, Bone Loss, Implant Survival, and Quality of Life.

    Science.gov (United States)

    Becker, William; Hujoel, Philippe; Becker, Burton E; Wohrle, Peter

    2016-06-01

    To evaluate aged partially and fully edentulous patients who received dental implants and were maintained over time. Further, to determine how the partially and edentulous ageing populations (65 and above) with dental implants maintain bone levels, proper oral hygiene, and perceive benefits of dental implants. Since 1995, patients receiving dental implants have been prospectively entered into an Access-based computerized program (Triton Tacking System). Patient demographics (age, sex), bone quality, quantity, implant location, and type of surgery have been continuously entered into the database. The database was queried for patients receiving implants (first stage) between 66 and 93 years of age. Thirty-one patients were within this age group. Twenty-five patients returned to the clinic for periodontal and dental implant evaluation. The Periodontal Index was used to evaluate selected teeth in terms of probing depth, bleeding on probing, plaque accumulation, and mobility. Using NIH Image J, radiographs taken at second stage and last examination were measured for changes in interproximal bone levels. Once identified, each patient anomalously filled out an abbreviated quality of health life form. Due to small sample size, descriptive statistics were used to compare clinical findings. Fifteen males ranging from 78 to 84 (mean age 84 years) years and 16 females from 66 to 93 (mean age 83 years) (age range 66-93) were contacted by phone or mail and asked to return to our office for a re-examination. For this group, the first dental implants were placed in 1996 (n = initial two implants) and continuously recorded through 2013 (n = last seven implants). Thirty-one patients received a total of 84 implants. Two patients were edentulous, and the remaining were partially edentulous. Four implants were lost. Between implant placement and 6- to 7-year interval, 13 patients with 40 implants had a cumulative survival rate of 94.6%. Of the original group (n = 33), three

  1. Dental implants modified with drug releasing titania nanotubes: therapeutic potential and developmental challenges.

    Science.gov (United States)

    Gulati, Karan; Ivanovski, Sašo

    2017-08-01

    The transmucosal nature of dental implants presents a unique therapeutic challenge, requiring not only rapid establishment and subsequent maintenance of osseointegration, but also the formation of resilient soft tissue integration. Key challenges in achieving long-term success are sub-optimal bone integration in compromised bone conditions and impaired trans-mucosal tissue integration in the presence of a persistent oral microbial biofilm. These challenges can be targeted by employing a drug-releasing implant modification such as TiO 2 nanotubes (TNTs), engineered on titanium surfaces via electrochemical anodization. Areas covered: This review focuses on applications of TNT-based dental implants towards achieving optimal therapeutic efficacy. Firstly, the functions of TNT implants will be explored in terms of their influence on osseointegration, soft tissue integration and immunomodulation. Secondly, the developmental challenges associated with such implants are reviewed including sterilization, stability and toxicity. Expert opinion: The potential of TNTs is yet to be fully explored in the context of the complex oral environment, including appropriate modulation of alveolar bone healing, immune-inflammatory processes, and soft tissue responses. Besides long-term in vivo assessment under masticatory loading conditions, investigating drug-release profiles in vivo and addressing various technical challenges are required to bridge the gap between research and clinical dentistry.

  2. Mecanobiología de la interfase hueso-implante dental

    Directory of Open Access Journals (Sweden)

    Juan Carlos Vanegas Acosta

    2010-03-01

    Full Text Available La osteointegración es la conexión estructural y funcional entre el hueso y un implante. Cuando un implante se inserta en el hueso, se crea la denominada interfase hueso-implante, una zona de unión entre la superficie del biomaterial del implante y el hueso circundante. La cicatrización de esta interfase depende de las condiciones biológicas del hueso, las características de diseño del implante y la distribución de cargas entre hueso e implante. En este artículo se hace una revisión del proceso de cicatrización de la interfase hueso-implante para el caso de un implante dental. El objetivo es describir la secuencia de eventos biológicos iniciados con la lesión causada por la inserción del implante y que concluyen con la formación de nuevo hueso en la interfase. Esta descripción incluye una novedosa clasificación de los fenómenos mecánicos que intervienen durante el proceso de cicatrización de los tejidos lesionados. Esta descripción mecanobiológica de la interfase hueso-implante dental se utiliza para determinar las características más relevantes a tener en cuenta en la formulación de un modelo matemático de la osteointegración de implantes dentales.

  3. Osseointegration of dental implants in patients with and without radiotherapy

    International Nuclear Information System (INIS)

    Wagner, W.; Esser, E.; Ostkamp, K.

    1998-01-01

    Between 1987 and 1997, 275 dental implants were inserted in the mandibles of 63 patients with squamous cell carcinoma of the lower oropharyngeal level following a radical surgical procedure. Thirty-five of these patients had been preirradiated with a complete dose of 60 Gy. In a retrospective analysis we have reviewed the data of these patients for age, sex, localization of the implants, irradiation, interval of implantation and interval of the abutment operation. Thus far, the median follow-up time is 65 months. The 5-year success rate for all implants was 97.9%. We found that radiotherapy, age, sex, localization of implantation or the interval between the end of the tumor therapy and the time of implantation did not have any significant influence on osseointegration or loss of osseointegration. Only the time interval between implantation and the abutment operation was recorded to be of any great significance (p=0.0001). No augmentation in the osteoradionecrosis rate could be recorded after dental implantation (1.6%), which leads us to conclude that radiotherapy (60 Gy) in patients with head and neck cancers should not be regarded as a contraindication for dental implantation. (orig.)

  4. New methods for oral rehabilitation with the dental implant

    International Nuclear Information System (INIS)

    Chang Joon Yim; Marx, R.E.

    1999-01-01

    Now autogenous bone and allogeneic bone implants offer a wide variety of surgical options to surgeons in the advanced dental implant surgery, whether its used separately or in combination. The surgeons are able to make judicious and fruitful choices, only with a thorough knowledge of the basic biological principles and skillful techniques. Further development of the new materials or new techniques in bone grafts has enabled the clinicians to repair even the most difficult bony defects successfully during dental implant surgery. Currently, researchers' and clinicians' interests were focused on the various growth factors such as PDGF, TGF-beta or BMPs. Platelets has been known as a source of PDGF and TGF-beta. Current technique of autogenous cancellous cellular bone graft mixed with the patient's own concentrated platelet rich plasma(PRP) gel has been developed. Several recombinant human BMP(rh-BMP)s has been studied for human clinical trial in a variety of bone defect cases related to the dental implants and FDA approval. Some showed favorable results. Rh-BMP7 was clinically tried to fill the space defects after lifting the Schneiderian membrane in the maxillary sinus of the patient. In several months dental implants were successfully placed at the edentulous maxillae where the maxillary sinus defects has been filled with rh-BMP will be discussed. The authors will introduce the basic ideas, basic histological study and the current techniques of bone grafts mixed with autogenous platelet concentrates gel and its clinical cases applied for the dental implant surgery. The idea of 'tent pole' technique was applied for the severely atrophic mandible and the results were predictable

  5. Recent advances in dental implants.

    Science.gov (United States)

    Hong, Do Gia Khang; Oh, Ji-Hyeon

    2017-12-01

    Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

  6. A concise overview of dental implantology

    Directory of Open Access Journals (Sweden)

    Olanrewaju Abdurrazaq Taiwo

    2015-01-01

    Full Text Available Background: The emergence of osseointegrated dental implants has resulted in several applications in diverse clinical settings. Hence, has contributed to the suitable replacement of missing teeth and the realization of an optimal facial appearance. This paper describes the benefits, applications, contraindications, and complications of dental implants in contemporary dental practice. Materials and Methods: An electronic search was undertaken in PUBMED without time restriction for appropriate English papers on dental implants based on a series of keywords in different combinations. Results: Fifty-eight acceptable, relevant articles were selected for review. The review identified the various components of dental implants, classification, and brands. It also looked at osseointegration and factors promoting and inimical to it. It also explored primary and secondary stability; and patients' selection for a dental implant. Complications of dental implants were also highlighted. Conclusion: With over 95% success rate, dental implants remain the gold standard for achieving aesthetic and functional oral rehabilitation.

  7. A conceptual knowledge-link model for supporting dental implant process

    OpenAIRE

    Szejka , Anderson Luis; Canciglieri , Osiris ,; Rudek , Marcelo; Panetto , Hervé

    2014-01-01

    International audience; Computer aided techniques widely used as diagnostic and surgical procedures tools are scarcely applied in implantology, which continues using visualization of CT images to define the parameters for dental implant process leaving to the dentist discretion the implant determination, since only the images analysis is non-deterministic. Thus, this research proposes the development of a knowledge-link model integrated to a reasoner system to support dental implant process t...

  8. The dosimetric impact of dental implants on head-and-neck volumetric modulated arc therapy

    International Nuclear Information System (INIS)

    Lin, Mu-Han; Li Jinsheng; Price, Robert A Jr; Wang Lu; Ma, C-M; Lee, Chung-Chi

    2013-01-01

    This work aims to investigate the dosimetric impact of dental implants on volumetric modulated arc therapy (VMAT) for head-and-neck patients and to evaluate the effectiveness of using the material's electron-density ratio for the correction. An in-house Monte Carlo (MC) code was utilized for the dose calculation to account for the scattering and attenuation caused by the high-Z implant material. Three different dental implant materials were studied in this work: titanium, Degubond®4 and gold. The dose perturbations caused by the dental implant materials were first investigated in a water phantom with a 1 cm 3 insert. The per cent depth dose distributions of a 3 × 3 cm 2 photon field were compared with the insert material as water and the three selected dental implant materials. To evaluate the impact of the dental implant on VMAT patient dose calculation, four head-and-neck cases were selected. For each case, the VMAT plan was designed based on the artifact-corrected patient geometry using a treatment planning system (TPS) that was typically utilized for routine patient treatment. The plans were re-calculated using the MC code for five situations: uncorrected geometry, artifact-corrected geometry and artifact-corrected geometry with one of the three different implant materials. The isodose distributions and the dose–volume histograms were cross-compared with each other. To evaluate the effectiveness of using the material's electron-density ratio for dental implant correction, the implant region was set as water with the material's electron-density ratio and the calculated dose was compared with the MC simulation with the real material. The main effect of the dental implant was the severe attenuation in the downstream. The 1 cm 3 dental implant can lower the downstream dose by 10% (Ti) to 51% (Au) for a 3 × 3 cm 2 field. The TPS failed to account for the dose perturbation if the dental implant material was not precisely defined. For the VMAT patient dose

  9. The Influence of Torque Tightening on the Position Stability of the Abutment in Conical Implant-Abutment Connections.

    Science.gov (United States)

    Hogg, Wiebke Semper; Zulauf, Kris; Mehrhof, Jürgen; Nelson, Katja

    2015-01-01

    The influence of repeated system-specific torque tightening on the position stability of the abutment after de- and reassembly of the implant components was evaluated in six dental implant systems with a conical implant-abutment connection. An established experimental setup was used in this study. Rotation, vertical displacement, and canting moments of the abutment were observed; they depended on the implant system (P = .001, P abutment screw does not eliminate changes in position of the abutment.

  10. The immediate insertion, loading and provisional prosthetic restoration of dental implants.

    Science.gov (United States)

    Sârbu, I

    2008-01-01

    The immediate insertion and loading of dental implants although used in the past as an alternative method for the surgical phase of the dental implant treatment is today becoming more and more popular due to its immediate and spectacular results. With information on bone density and a careful patient selection, this method has increased chances of success. Its main advantage is the high degree of patient comfort with a great aesthetic effect. This article presents the theoretical and practical technique used on two clinical cases of dental implantation and their outcome.

  11. Imunohistological aspects of the tissue around dental implants

    Science.gov (United States)

    Nimigean, Victor; Nimigean, Vanda R.; Sǎlǎvǎstru, Dan I.; Moraru, Simona; BuÅ£incu, Lavinia; Ivaşcu, Roxana V.; Poll, Alexandru

    2016-03-01

    Objectives: study of soft and hard tissues around implants. Material and methods: For the immunohistochemical and histological study of the implant/soft tissue interface, we examined pieces of peri-implant mucosa harvested from 35 patients. The implant/bone interface was assessed using histologic and histomorphometric examination of hard tissues around unloaded, early loaded or delayed loaded dental implants with pre-established design, with a sandblasted and acid-etched surface, placed both in extraction sockets, or after bone healing following tooth removal. This study was performed on 9 common race dogs. Results: The histological study of the implant/soft tissue interface showed regenerative modifications and moderate chronic subepithelial inflammatory reactions. Immunohistochemical evaluation of the soft tissue biopsies revealed the presence of specific immunocompetent cells and proteins of the matrix metalloproteinase (MMP) expression. Bone-implants contacts were more obvious in the apical half of the implants and at the edges of the threads, than between them. A mature, lamelliform bone containing lacunae with osteocytes and lack of connective tissue were noticed around implants that were late placed and loaded. The new-formed bone was also abundant in the crestal zone, not only in the apical part of the implants. Conclusions: A thorough understanding of the microstructure of dental implant/soft and hard tissue interface will improve the longevity of osseointegrated implants.

  12. Chronological Age as Factor Influencing the Dental Implant Osseointegration in the Jaw Bone

    Directory of Open Access Journals (Sweden)

    Jan Papež

    2018-04-01

    Full Text Available The objectives of this study were to evaluate osseointegration of dental implant in the jaw bone in the young and elderly population and comparing the results to assess indicators and risk factors as age for the success or failure of dental implants. A retrospective study of 107 implants (Impladent, LASAK, Czech Republic was prepared. The patients at implants surgery were divided in three groups. The patients were followed-up for a 7-year period. We evaluated osseointegration from long term point of view as a change of marginal bone levels close to dental implant. Marginal bone levels were recorded and analysed with regard to different patient- and implant-related factors. An influence of chronological age on change of marginal bone levels during 6-year retrospective study vas evaluated. The study examined 47 patient charts and 107 implants from the Second Faculty of Medicine, Charles University and University Hospital Motol. We proved that young healthy patients with long bridges or Branemarks have the same progression of marginal bone levels changes. The chronological age hasn’t therefore direct influence on the osseointegration from long term point of view. But we found that the length of dental suprastrucure-prosthetic construction negatively influences marginal bone changes, though these results weren’t statistically significant. More extensive dental implant suprastrucure undergoes smaller osseointegration. On the other hand the length of dental suprastrucure (prosthetic construction negatively influences dental osseointegration in both groups of patient.

  13. Pansinusitis y afectación intracraneal por implante dental Pansinusitis and intracranial impact of a dental implant

    Directory of Open Access Journals (Sweden)

    Josep Rubio-Palau

    2012-03-01

    Full Text Available Las sinusitis odontógenas son una patología relativamente frecuente causada por infecciones dentales, quistes periapicales así como tras procedimientos bucodentales como una endodoncia, una elevación sinusal o la colocación de un implante. A continuación se presenta un caso extremo de una pansinusitis derecha con fistulización a espacio epidural causada por un implante osteointegrado. Ante la sospecha de una sinusitis maxilar de origen odontogénico se debe iniciar rápidamente un tratamiento antibiótico correcto y un seguimiento estrecho ya que pueden tener consecuencias fatales como la pérdida de un ojo, abscesos cerebrales o incluso la muerte.Odontogenic sinusitis is a relatively common disease caused by dental infections, periapical cysts and oral procedures such as root canal, sinus lift or implant placement. We report an extreme case of a right pansinusitis with an epidural space fistula caused by osseointegrated implants. When maxillary sinusitis of odontogenic origin is suspected, we should quickly start effective antibiotic treatment and monitor the patient closely because odontogenic sinusitis can have serious consequences, such as the loss of an eye, brain abscess or death.

  14. Efficacy of Octacalcium Phosphate Collagen Composite for Titanium Dental Implants in Dogs

    Directory of Open Access Journals (Sweden)

    Tadashi Kawai

    2018-02-01

    Full Text Available Background: Previous studies showed that octacalcium (OCP collagen composite (OCP/Col can be used to repair human jaw bone defects without any associated abnormalities. The present study investigated whether OCP/Col could be applied to dental implant treatment using a dog tooth extraction socket model. Methods: The premolars of dogs were extracted; each extraction socket was extended, and titanium dental implants were placed in each socket. OCP/Col was inserted in the space around a titanium dental implant. Autologous bone was used to fill the other sockets, while the untreated socket (i.e., no bone substitute material served as a control. Three months after the operation, these specimens were analyzed for the osseointegration of each bone substitute material with the surface of the titanium dental implant. Results: In histomorphometric analyses, the peri-implant bone areas (BA% and bone-implant contact (BIC% were measured. There was no difference in BA% or BIC% between OCP/Col and autologous bone. Conclusion: These results suggested that OCP/Col could be used for implant treatment as a bone substitute.

  15. Heat generated by dental implant drills during osteotomy-a review: heat generated by dental implant drills.

    Science.gov (United States)

    Mishra, Sunil Kumar; Chowdhary, Ramesh

    2014-06-01

    Osseointegration is the more stable situation and results in a high success rate of dental implants. Heat generation during rotary cutting is one of the important factors influencing the development of osseointegration. To assess the various factors related to implant drills responsible for heat generation during osteotomy. To identify suitable literature, an electronic search was performed using Medline and Pubmed database. Articles published in between 1960 to February 2013 were searched. The search is focused on heat generated by dental implant drills during osteotomy. Various factors related to implant drill such effect of number of blades; drill design, drill fatigue, drill speed and force applied during osteotomies which were responsible for heat generation were reviewed. Titles and abstracts were screened, and literature that fulfilled the inclusion criteria was selected for a full-text reading. The initial literature search resulted in 299 articles out of which only 70 articles fulfils the inclusion criteria and were included in this systematic review. Many factors related to implant drill responsible for heat generation were found. Successful preparation of an implant cavity with minimal damage to the surrounding bone depends on the avoidance of excessive temperature generation during surgical drilling. The relationship between heat generated and implant drilling osteotomy is multifactorial in nature and its complexity has not been fully studied. Lack of scientific knowledge regarding this issue still exists. Further studies should be conducted to determine the various factors which generate less heat while osteotomy such as ideal ratio of force and speed in vivo, exact time to replace a drill, ideal drill design, irrigation system, drill-bone contact area.

  16. Effect of Macrogeometry on the Surface Topography of Dental Implants.

    Science.gov (United States)

    Naves, Marina Melo; Menezes, Helder Henrique Machado; Magalhães, Denildo; Ferreira, Jessica Afonso; Ribeiro, Sara Ferreira; de Mello, José Daniel Biasoli; Costa, Henara Lillian

    2015-01-01

    Because the microtopography of titanium implants influences the biomaterial-tissue interaction, surface microtexturing treatments are frequently used for dental implants. However, surface treatment alone may not determine the final microtopography of a dental implant, which can also be influenced by the implant macrogeometry. This work analyzed the effects on surface roughness parameters of the same treatment applied by the same manufacturer to implants with differing macro-designs. Three groups of titanium implants with different macro-designs were investigated using laser interferometry and scanning electron microscopy. Relevant surface roughness parameters were calculated for different regions of each implant. Two flat disks (treated and untreated) were also investigated for comparison. The tops of the threads and the nonthreaded regions of all implants had very similar roughness parameters, independent of the geometry of the implant, which were also very similar to those of flat disks treated with the same process. In contrast, the flanks and valleys of the threads presented larger irregularities (Sa) with higher slopes (Sdq) and larger developed surface areas (Sdr) on all implants, particularly for implants with threads with smaller heights. The flanks and valleys displayed stronger textures (Str), particularly on the implants with threads with larger internal angles. Parameters associated with the height of the irregularities (Sa), the slope of the asperities (Sdq), the presence of a surface texture (Str), and the developed surface area of the irregularities (Sdr) were significantly affected by the macrogeometry of the implants. Flat disks subjected to the same surface treatment as dental implants reproduced only the surface topography of the flat regions of the implants.

  17. Occlusal stability in shortened dental arches.

    Science.gov (United States)

    Witter, D J; Creugers, N H; Kreulen, C M; de Haan, A F

    2001-02-01

    Shortened dental arches consisting of anterior and premolar teeth have been shown to meet oral functional demands. However, the occlusal stability may be at risk as a result of tooth migration. The aim of this nine-year study was to investigate occlusal stability in shortened dental arches as a function over time. Occlusal stability indicators were: 'interdental spacing', 'occlusal contacts of anterior teeth in Intercuspal Position', 'overbite', 'occlusal tooth wear', and 'alveolar bone support'. Subjects with shortened dental arches (n = 74) were compared with subjects with complete dental arches (controls, n = 72). Repeated-measurement regression analyses were applied to assess age-dependent variables in the controls and to relate the occlusal changes to the period of time since the treatment that led to the shortened dental arches. Compared with complete dental arches, shortened dental arches had similar overbite and occlusal tooth wear. They showed more interdental spacing in the premolar regions, more anterior teeth in occlusal contact, and lower alveolar bone scores. Since the differences remained constant over time, we conclude that shortened dental arches can provide long-term occlusal stability. Occlusal changes were self-limiting, indicating a new occlusal equilibrium.

  18. A novel dental implant abutment with micro-motion capability--development and biomechanical evaluations.

    Science.gov (United States)

    Chen, Yen-Yin; Chen, Weng-Pin; Chang, Hao-Hueng; Huang, Shih-Hao; Lin, Chun-Pin

    2014-02-01

    The aim of this study was to develop a novel dental implant abutment with a micro-motion mechanism that imitates the biomechanical behavior of the periodontal ligament, with the goal of increasing the long-term survival rate of dental implants. Computer-aided design software was used to design a novel dental implant abutment with an internal resilient component with a micro-motion capability. The feasibility of the novel system was investigated via finite element analysis. Then, a prototype of the novel dental implant abutment was fabricated, and the mechanical behavior was evaluated. The results of the mechanical tests and finite element analysis confirmed that the novel dental implant abutment possessed the anticipated micro-motion capability. Furthermore, the nonlinear force-displacement behavior apparent in this micro-motion mechanism imitated the movement of a human tooth. The slope of the force-displacement curve of the novel abutment was approximately 38.5 N/mm before the 0.02-mm displacement and approximately 430 N/mm after the 0.03-mm displacement. The novel dental implant abutment with a micro-motion mechanism actually imitated the biomechanical behavior of a natural tooth and provided resilient function, sealing, a non-separation mechanism, and ease-of-use. Copyright © 2013 Academy of Dental Materials. All rights reserved.

  19. REFRACTORY CEPHALEA AND RHINITIS FOLLOWING DENTAL IMPLANT

    Directory of Open Access Journals (Sweden)

    ENRIQUE COSCARÓN-BLANCO

    2018-05-01

    Full Text Available INTRODUCTION: Dental implants are prosthetic devices that are inserted into the thickness of the bone of the maxilla for osseointegration using a screw system. They are increasingly used for both functional and aesthetic reasons. As in any medical or surgical procedure, there are some typical risks and possible sequelae that must be explained and prevented. However, sometimes not-associated-with-implantation rare complications that can cause great morbidity and decrease in the quality of life of the implant recipient can occur. A case of an unusual complication is reported,MATERIAL AND METHODS: A 65-year-old woman presented with a permanent mainly right-sided bilateral nasal obstruction with frequent watery rhinorrhea and headache with retro-orbital and infraorbital irradiation refractory to broad-spectrum antibiotic treatment, corticosteroids and analgesics that she associated with a dental implant two weeks before. . Sinusitis or implant-related complication were ruled out by the dentist and her Primary Care Physician, and therefore she was referred to otorhinolaryngological assessment after radiological study with maxillary sinuses free of disease. The physical examination demostrated inferior obstructive hypertrophic turbinates from the anterior third and thick clear rhinorrhea. After topic tetracaine with adrenaline ,retraction of the turbinates revealed a screw that after breaking the floor of the right nostril entered the thickness of the inferior turbinate. In the left nostril, soil procidence is identified with turbinal contact. An orthopantomography demonstrated the findings described above, highlighting also how the implant was inserted into the skeleton of the inferior turbinate. The sympthoms resolved after removal of the implant. Topical oxymetazoline and corticosteroids provided little relief meanwhile. DISCUSSION AND CONCLUSIONS: The functional objectives sought with dental implants can be compromised by complications such as the

  20. Viability of dental implants in head and neck irradiated patients: A systematic review.

    Science.gov (United States)

    Zen Filho, Edson Virgílio; Tolentino, Elen de Souza; Santos, Paulo Sérgio Silva

    2016-04-01

    The purpose of this systematic review was to evaluate the safety of dental implants placed in irradiated bone and to discuss their viability when placed post-radiotherapy (RT). A systematic review was performed to answer the questions: "Are dental implants in irradiated bone viable?" and "What are the main factors that influence the loss of implants in irradiated patients?" The search strategy resulted in 8 publications. A total of 331 patients received 1237 implants, with an overall failure rate of 9.53%. The osseointegration success rates ranged between 62.5% and 100%. The optimal time interval between irradiation and dental implantation varied from 6 to 15 months. The interval time between RT and implant placement and the radiation doses are not associated with significant implant failure rates. The placement of implants in irradiated bone is viable, and head and neck RT should not be considered as a contraindication for dental rehabilitation with implants. © 2015 Wiley Periodicals, Inc. Head Neck 38: E2229-E2240, 2016. © 2015 Wiley Periodicals, Inc.

  1. Management of dental implant fractures. A case history.

    Science.gov (United States)

    Al Quran, Firas A M; Rashan, Bashar A; Al-Dwairi, Ziad N

    2009-01-01

    The widespread use of endosseous osseointegrated implants to replace missing natural teeth increases the chances of implant complications and failures, despite the high initial success rate reported in the literature. Implant fracture is one possible complication that results in ultimate failure of the dental implant. Such a complication poses a management crisis even for the most experienced clinician. This article reports on a case of implant fracture, its possible causes, and how the case was managed.

  2. Experimental investigation of commercial small diameter dental implants in porcine mandibular segments.

    Science.gov (United States)

    Hasan, Istabrak; Heinemann, Friedhelm; Schwegmann, Monika; Keilig, Ludger; Stark, Helmut; Bourauel, Christoph

    2017-02-01

    Small diameter (mini) dental implants have become more popular in recent years as alternatives to classical implant treatment in clinical cases with critical bony situations. However, an in-depth scientific analysis of the mechanical and biomechanical effects of small diameter implants has not yet been published. The aim of the present study was to investigate experimentally different commercial mini implants by measuring their displacements under immediate loading. Twelve commercially available mini implants were measured. Implants were inserted into porcine mandibular segments and loaded by means of a predefined displacement of 0.5 mm of the loading system. The implants were loaded at an angle of 30° to the implant long axis using the self-developed biomechanical hexapod measurement system. Implant displacements were registered. The experimental results were compared to the numerical ones from a previous study. Measured implant displacements were within the range of 39-194 μm. A large variation in the displacements was obtained among the different implant systems due to the different designs and thread profiles. Comparing experimental and numerical results, the displacements that were obtained numerically were within the range of 79-347 μm. The different commercial mini implants showed acceptable primary stability and could be loaded immediately after their insertion.

  3. Immediate loading of subcrestally placed dental implants in anterior and premolar sites.

    Science.gov (United States)

    Henningsen, Anders; Smeets, Ralf; Köppen, Kai; Sehner, Susanne; Kornmann, Frank; Gröbe, Alexander; Heiland, Max; Gerlach, Till

    2017-11-01

    Immediate loading of dental implants has been evolving into an appropriate procedure for the treatment of partially edentulous jaws. The purpose of this study was to evaluate the clinical success and radiological outcome of immediately and delayed loaded dental implants in anterior and premolar sites. In this retrospective study, data of 163 individuals requiring tooth removal with subsequent implant placement in anterior and premolar sites were analyzed. Implants were immediately loaded by provisional acrylic resin bridges or loaded with delay. Implants were followed up annually for up to 9 years including intraoral radiographs. A total of 285 implants in 163 patients were placed. 218 implants were immediately loaded and 67 implants with delay. Fifteen implants failed during the follow-up period resulting in survival rates of 94.5% for immediate loading and 95.5% for delayed loading. After an initial decrease of 0.3 mm in the first 12 months the marginal bone level remained stable. No statistically significant differences were found in marginal bone loss between immediately and delayed loaded implants (P = 0.518, 95% CI). Within the limits of this study, immediate loading of immediately subcrestally placed dental implants in anterior and premolar sites is a reliable treatment option for dental rehabilitation. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  4. Analysis of the causes of dental implant fracture: A retrospective clinical study.

    Science.gov (United States)

    Stoichkov, Biser; Kirov, Dimitar

    2018-01-01

    Fracture of osseointegrated dental implants is the most severe mechanical complication. The aim of the present study was to analyze possible causative factors for implant body fracture. One hundred and one patients with 218 fitted implants and a follow-up period of 3 to 10 years were studied. Factors associated with biomechanical and physiologic overloading such as parafunctional activity (eg, bruxism), occlusion, and cantilevers, and factors related to the planning of the dental prosthesis, available bone volume, implant area, implant diameter, number of implants, and their inclination were tracked. The impact of their effect was analyzed using the Bonferroni-corrected post-hoc Mann-Whitney test for each group. The incidence of dental implant fracture was 2.3% in the investigated cases. Improper treatment planning, bruxism, and time of the complication setting in were the main factors leading to this complication. Typical size effect was established only for available bruxism, occlusal errors, and their activity duration. These complications were observed most often with single crown prostheses, and in combination with parafunctional activities such as bruxism and lack of implant-protected occlusion. Occlusal overload due to bruxism or inappropriate or inadequate occlusion as a single factor or a combination of these factors during the first years after the functional load can cause implant fracture. Fracture of the implant body more frequently occurred with single crowns than with other implant-supported fixed dental prostheses.

  5. Implant overdentures: dental students' performance in fabrication, denture quality, and patient satisfaction.

    Science.gov (United States)

    Aragon, Cecilia E; Cornacchio, Angelica Lee Petrina; Ibarra, Lilia Marcela; Saad, Muhammed N; Zibrowski, Elaine

    2010-09-01

    The purpose of this study was to evaluate dental students' performance when fabricating a mandibular two-implant overdenture (OD) as compared to conventional dentures (CD) and to determine if these prostheses were successful. Twenty students and twenty patients were divided into two groups: complete denture group (CDG) and maxillary denture and two-implant OD group (ODG). Students' progress was evaluated at each appointment as they were given a clinical assessment score (CAS), which varied from 1 (unacceptable, needs to repeat procedure) to 4 (acceptable, no errors). The success of the prosthesis was evaluated by the patients using a visual analog scale (VAS) and an expert (a prosthodontist) using a denture quality assessment (DQA) form. Performance for both groups was not statistically different across all eight appointments (CDG 3.16 versus ODG 3.25; p=0.46). Patients with ODs reported greater stability with their dentures (p=0.048) and greater ability to chew than patients with CDs (p=0.03). There were no differences between the groups in terms of expert appraisal (ODG 71.1 versus CDG 67.5; p=0.59). The performance of dental students when fabricating a two-implant OD is thus not different from that of a CD. Students can successfully fabricate a two-implant OD as perceived by both patients and prosthodontists.

  6. Factors associated with dental implant survival: a 4-year retrospective analysis.

    Science.gov (United States)

    Zupnik, Jamie; Kim, Soo-woo; Ravens, Daniel; Karimbux, Nadeem; Guze, Kevin

    2011-10-01

    Dental implants are a predictable treatment option for replacing missing teeth and have strong survival and success outcomes. However, previous research showed a wide array of potential risk factors that may have contributed to dental implant failures. The objectives of this study are to study if implant survival rates were affected by known risk factors and risk indicators that may have contributed to implant failures. The secondary outcome measures were whether the level of expertise of the periodontal residents affected success rates and how the rate of implant success at the Harvard School of Dental Medicine (HSDM) compared to published standards. A retrospective chart review of patients at the HSDM who had one of two types of rough-surface implants (group A or B) placed by periodontology residents from 2003 to 2006 was performed. Demographic, health, and implant data were collected and analyzed by multimodel analyses to determine failure rates and any factors that may have increased the likelihood of an implant failure. The study cohort included 341 dental implants. The odds ratio for an implant failure was most clearly elevated for diabetes (2.59 implant surface group B (7.84), and male groups (4.01). There was no significant difference regarding the resident experience. The success rate for HSDM periodontology residents was 96.48% during the 4-year study period. This study demonstrates that implant success rates at HSDM fell within accepted published standards, confirmed previously identified risk factors for a failure, and potentially suggested that other acknowledged risk factors could be controlled for. Furthermore, the level of experience of the periodontology resident did not have an impact on survival outcomes.

  7. Computer-assisted intraoperative visualization of dental implants. Augmented reality in medicine

    International Nuclear Information System (INIS)

    Ploder, O.; Wagner, A.; Enislidis, G.; Ewers, R.

    1995-01-01

    In this paper, a recently developed computer-based dental implant positioning system with an image-to-tissue interface is presented. On a computer monitor or in a head-up display, planned implant positions and the implant drill are graphically superimposed on the patient's anatomy. Electromagnetic 3D sensors track all skull and jaw movements; their signal feedback to the workstation induces permanent real-time updating of the virtual graphics' position. An experimental study and a clinical case demonstrates the concept of the augmented reality environment - the physician can see the operating field and superimposed virtual structures, such as dental implants and surgical instruments, without loosing visual control of the operating field. Therefore, the operation system allows visualization of CT planned implantposition and the implementation of important anatomical structures. The presented method for the first time links preoperatively acquired radiologic data, planned implant location and intraoperative navigation assistance for orthotopic positioning of dental implants. (orig.) [de

  8. A review of nanostructured surfaces and materials for dental implants: surface coating, patterning and functionalization for improved performance.

    Science.gov (United States)

    Rasouli, Rahimeh; Barhoum, Ahmed; Uludag, Hasan

    2018-05-10

    The emerging field of nanostructured implants has enormous scope in the areas of medical science and dental implants. Surface nanofeatures provide significant potential solutions to medical problems by the introduction of better biomaterials, improved implant design, and surface engineering techniques such as coating, patterning, functionalization and molecular grafting at the nanoscale. This review is of an interdisciplinary nature, addressing the history and development of dental implants and the emerging area of nanotechnology in dental implants. After a brief introduction to nanotechnology in dental implants and the main classes of dental implants, an overview of different types of nanomaterials (i.e. metals, metal oxides, ceramics, polymers and hydrides) used in dental implant together with their unique properties, the influence of elemental compositions, and surface morphologies and possible applications are presented from a chemical point of view. In the core of this review, the dental implant materials, physical and chemical fabrication techniques and the role of nanotechnology in achieving ideal dental implants have been discussed. Finally, the critical parameters in dental implant design and available data on the current dental implant surfaces that use nanotopography in clinical dentistry have been discussed.

  9. Anodized dental implant surface

    Directory of Open Access Journals (Sweden)

    Sunil Kumar Mishra

    2017-01-01

    Full Text Available Purpose: Anodized implants with moderately rough surface were introduced around 2000. Whether these implants enhanced biologic effect to improve the environment for better osseointegration was unclear. The purpose of this article was to review the literature available on anodized surface in terms of their clinical success rate and bone response in patients till now. Materials and Methods: A broad electronic search of MEDLINE and PubMed databases was performed. A focus was made on peer-reviewed dental journals. Only articles related to anodized implants were included. Both animal and human studies were included. Results: The initial search of articles resulted in 581 articles on anodized implants. The initial screening of titles and abstracts resulted in 112 full-text papers; 40 animal studies, 16 studies on cell adhesion and bacterial adhesion onto anodized surfaced implants, and 47 human studies were included. Nine studies, which do not fulfill the inclusion criteria, were excluded. Conclusions: The long-term studies on anodized surface implants do favor the surface, but in most of the studies, anodized surface is compared with that of machined surface, but not with other surfaces commercially available. Anodized surface in terms of clinical success rate in cases of compromised bone and immediately extracted sockets has shown favorable success.

  10. Survival of dental implants in patients with Down syndrome: A case series.

    Science.gov (United States)

    Limeres Posse, Jacobo; López Jiménez, Julian; Ruiz Villandiego, José C; Cutando Soriano, Antonio; Fernández Feijoo, Javier; Linazasoro Elorza, Maialen; Diniz Freitas, Márcio; Diz Dios, Pedro

    2016-12-01

    The need for tooth replacement in individuals with Down syndrome (DS) is explained by the high prevalence of dental agenesis and by the premature loss of teeth through severe periodontal disease. Dental implants may be the dental procedure of choice in some of these patients. The purpose of this clinical study was to analyze dental implant survival in a series of patients with DS. This was a multicenter, retrospective, observational study. Information on patients was gathered using a standardized questionnaire designed specifically for this study, including personal details, oral health status, information on the surgical and prosthetic phases, and follow-up visits. The questionnaire was sent to centers registered with the research network of the Spanish Society of Special Needs Dentistry (SEOENE). Patients with DS aged 18 years or older were included in the study if they had at least 1 dental implant and the corresponding prosthesis and had been followed up for at least a year. The study population was formed of 25 adult patients (13 men and 12 women) aged between 19 and 60 years. The interventions were performed by 5 different dental surgeons, usually under general anesthesia or deep sedation (n=17 patients). A total of 73 implants were inserted, 30 in the maxilla and 43 in the mandible, most commonly in the anterior region (n=51). The mean time to loading the implants was 4.1 ±1.3 months after surgery (range, 1 to 7 months). All patients completed prosthetic rehabilitation; the most frequent design used was the single fixed prosthesis (n=13 patients). A total of 17 (23.2%) implants failed in 8 (32%) patients; the majority (n=14 implants) failed in the postsurgical period before implant loading. The distribution by patients was 1 implant failure in 6 patients, 3 failures in 1 patient, and 8 failures in 1 patient. Dental implant survival is lower in individuals with DS than in the general population. The reasons for early implant failure in these patients have

  11. Stability of implants placed in fresh sockets versus healed alveolar sites: Early findings.

    Science.gov (United States)

    Gehrke, Sergio Alexandre; da Silva Neto, Ulisses Tavares; Rossetti, Paulo Henrique Orlato; Watinaga, Sidney Eiji; Giro, Gabriela; Shibli, Jamil Awad

    2016-05-01

    The present study measured implant stability quotient (ISQ) values at three different time points after surgical procedures to compare whether the stability values differed between implants placed in fresh extraction sockets versus healed alveolar sites. To measure implant stability, resonance frequency analysis (RFA) was performed in 77 patients (53 women, 24 men) with a total of 120 dental implants. These implants were divided into two groups: Group 1 included 60 implants in healed alveolar sites (22 in the maxilla, 38 in the mandible), and Group 2 included 60 implants in fresh sockets (41 in the maxilla, 19 in the mandible). Implant stability was measured immediately at implant placement (baseline), 90, and 150 days later. Statistical analysis was made using a multivariate regression linear model at implant level (α = 0.05). Overall, the means and standard deviations of the ISQ values were 62.7 ± 7.14 (95% confidence interval [CI], 39-88) at baseline, 70.0 ± 6.22 (95% CI, 46-88) at 90 days, and 73.4 ± 5.84 (95% CI, 58-88) at 150 days. In Group 1, the ISQs ranged between 64.3 ± 6.20 and 75.0 ± 5.69, while in Group 2, presented lower values that ranged between 61.2 ± 8.09 and 71.9 ± 5.99 (P = 0.002). Anatomic location and times periods were the only identified variables with an influence on ISQ values at implant level (P sockets and in healed sites exhibited similar evolutions in ISQ values and thus osseointegration; however, the implants in the healed alveolar sites exhibited superior values at all time points. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. In situ microradioscopy and microtomography of fatigue-loaded dental two-piece implants.

    Science.gov (United States)

    Wiest, Wolfram; Zabler, Simon; Rack, Alexander; Fella, Christian; Balles, Andreas; Nelson, Katja; Schmelzeisen, Rainer; Hanke, Randolf

    2015-11-01

    Synchrotron real-time radioscopy and in situ microtomography are the only techniques providing direct visible information on a micrometre scale of local deformation in the implant-abutment connection (IAC) during and after cyclic loading. The microgap formation at the IAC has been subject to a number of studies as it has been proposed to be associated with long-term implant success. The next step in this scientific development is to focus on the in situ fatigue procedure of two-component dental implants. Therefore, an apparatus has been developed which is optimized for the in situ fatigue analysis of dental implants. This report demonstrates both the capability of in situ radioscopy and microtomography at the ID19 beamline for the study of cyclic deformation in dental implants. The first results show that it is possible to visualize fatigue loading of dental implants in real-time radioscopy in addition to the in situ fatigue tomography. For the latter, in situ microtomography is applied during the cyclic loading cycles in order to visualize the opening of the IAC microgap. These results concur with previous ex situ studies on similar systems. The setup allows for easily increasing the bending force, to simulate different chewing situations, and is, therefore, a versatile tool for examining the fatigue processes of dental implants and possibly other specimens.

  13. Effect of Polyvinyl Siloxane Viscosity on Accuracy of Dental Implant Impressions

    Directory of Open Access Journals (Sweden)

    Ahmad Ghahremanloo

    2017-02-01

    Full Text Available Objectives: The aim of this study was to compare the accuracy of dental implant impressions obtained by a combination of different impression techniques and viscosities of polyvinyl siloxane (PVS.Materials and Methods: Four parallel fixtures were placed between mental foramina in a master model of lower dental arch. Three different viscosities (putty/light body, medium body/light body, and monophase: heavy body and direct and indirect techniques (six groups were used, and seven impressions were obtained from each group (n=42. To measure the accuracy of impressions, drift, horizontal, and vertical angles of the implants, as well as the hex rotation of the implants in casts were evaluated using a digitizer device (1μm accuracy, in comparison with master arch. Data were analyzed using five-factor two-way ANOVA and Tukey’s post-hoc test.Results: The accuracy of impressions was assessed and the results showed that direct technique was not significantly different from indirect technique (P>0.05. Also, there were no significant differences between the mentioned viscosities except for the horizontal angle (P=0.006.Conclusions: Viscosity of impression materials is of high significance for the accuracy of dental impressions.Keywords: Dental Materials; Dental Implants; Dental Impression Technique; Viscosity; Vinyl Polysiloxane; Dimensional Measurement Accuracy

  14. In situ microradioscopy and microtomography of fatigue-loaded dental two-piece implants

    Energy Technology Data Exchange (ETDEWEB)

    Wiest, Wolfram; Zabler, Simon, E-mail: simon.zabler@physik.uni-wuerzburg.de [University of Würzburg (Germany); Rack, Alexander [European Synchrotron Radiation Facility (France); Fella, Christian; Balles, Andreas [University of Würzburg (Germany); Nelson, Katja; Schmelzeisen, Rainer [Medical Centre – University of Freiburg (Germany); Hanke, Randolf [University of Würzburg (Germany); Fraunhofer EZRT, Fürth (Germany)

    2015-10-09

    Results of a novel in situ microradiography and microtomography setup for the study of fatigue processes are presented. This setup is optimized for the requirements of dental implants and use at synchrotron imaging beamlines. Synchrotron real-time radioscopy and in situ microtomography are the only techniques providing direct visible information on a micrometre scale of local deformation in the implant–abutment connection (IAC) during and after cyclic loading. The microgap formation at the IAC has been subject to a number of studies as it has been proposed to be associated with long-term implant success. The next step in this scientific development is to focus on the in situ fatigue procedure of two-component dental implants. Therefore, an apparatus has been developed which is optimized for the in situ fatigue analysis of dental implants. This report demonstrates both the capability of in situ radioscopy and microtomography at the ID19 beamline for the study of cyclic deformation in dental implants. The first results show that it is possible to visualize fatigue loading of dental implants in real-time radioscopy in addition to the in situ fatigue tomography. For the latter, in situ microtomography is applied during the cyclic loading cycles in order to visualize the opening of the IAC microgap. These results concur with previous ex situ studies on similar systems. The setup allows for easily increasing the bending force, to simulate different chewing situations, and is, therefore, a versatile tool for examining the fatigue processes of dental implants and possibly other specimens.

  15. In situ microradioscopy and microtomography of fatigue-loaded dental two-piece implants

    International Nuclear Information System (INIS)

    Wiest, Wolfram; Zabler, Simon; Rack, Alexander; Fella, Christian; Balles, Andreas; Nelson, Katja; Schmelzeisen, Rainer; Hanke, Randolf

    2015-01-01

    Results of a novel in situ microradiography and microtomography setup for the study of fatigue processes are presented. This setup is optimized for the requirements of dental implants and use at synchrotron imaging beamlines. Synchrotron real-time radioscopy and in situ microtomography are the only techniques providing direct visible information on a micrometre scale of local deformation in the implant–abutment connection (IAC) during and after cyclic loading. The microgap formation at the IAC has been subject to a number of studies as it has been proposed to be associated with long-term implant success. The next step in this scientific development is to focus on the in situ fatigue procedure of two-component dental implants. Therefore, an apparatus has been developed which is optimized for the in situ fatigue analysis of dental implants. This report demonstrates both the capability of in situ radioscopy and microtomography at the ID19 beamline for the study of cyclic deformation in dental implants. The first results show that it is possible to visualize fatigue loading of dental implants in real-time radioscopy in addition to the in situ fatigue tomography. For the latter, in situ microtomography is applied during the cyclic loading cycles in order to visualize the opening of the IAC microgap. These results concur with previous ex situ studies on similar systems. The setup allows for easily increasing the bending force, to simulate different chewing situations, and is, therefore, a versatile tool for examining the fatigue processes of dental implants and possibly other specimens

  16. Impact of dental implant insertion method on the peri-implant bone tissue: Experimental study

    Directory of Open Access Journals (Sweden)

    Stamatović Novak

    2013-01-01

    Full Text Available Background/Aim. The function of dental implants depends on their stability in bone tissue over extended period of time, i.e. on osseointegration. The process through which osseointegration is achieved depends on several factors, surgical insertion method being one of them. The aim of this study was to histopathologically compare the impact of the surgical method of implant insertion on the peri-implant bone tissue. Methods. The experiment was performed on 9 dogs. Eight weeks following the extraction of lower premolars implants were inserted using the one-stage method on the right mandibular side and two-stage method on the left side. Three months after implantation the animals were sacrificed. Three distinct regions of bone tissue were histopathologically analyzed, the results were scored and compared. Results. In the specimens of one-stage implants increased amount of collagen fibers was found in 5 specimens where tissue necrosis was also observed. Only moderate osteoblastic activity was found in 3 sections. The analysis of bone-to-implant contact region revealed statistically significantly better results regarding the amount of collagen tissue fibers for the implants inserted in the two-stage method (Wa = 59 105, α = 0.05. No necrosis and osteoblastic activity were observed. Conclusion. Better results were achieved by the two-stage method in bone-to-implant contact region regarding the amount of collagen tissue, while the results were identical regarding the osteoblastic activity and bone tissue necrosis. There was no difference between the methods in the bone-implant interface region. In the bone tissue adjacent to the implant the results were identical regarding the amount of collagen tissue, osteoblastic reaction and bone tissue necrosis, while better results were achieved by the two-stage method regarding the number of osteocytes.

  17. Need of implant dentistry at undergraduate dental curriculum in Indian dental colleges

    Directory of Open Access Journals (Sweden)

    Ramesh Chowdhary

    2011-01-01

    Full Text Available Edentulism is the major problem in the developing countries, and is widely spread in the current population, although the prevalence is declining and incidence of tooth loss is decreasing in the developed nations. The prevalence of edentulism in India varies from 60% to 69% of 25 years and above age group. It is obvious that the number of lost teeth increases with age leading to an increase in prevalence of partially edentulous patients. From a biological point of view, the replacement of a single missing tooth with an implant rather than a three-unit fixed partial denture, and the implant-supported complete denture has been proved more efficient in improving the mastication and maintaining the bone for a longer time and also more cost-effective treatment. Many dental schools throughout Europe and America have to a various extent introduced implant dentistry as part of the compulsory undergraduate curriculum. Thus, it becomes more essential to introduce implant dentistry at undergraduate level in Indian dental schools to manage the higher percentage of edentulism.

  18. Assessment of Various Risk Factors for Success of Delayed and Immediate Loaded Dental Implants: A Retrospective Analysis.

    Science.gov (United States)

    Prasant, M C; Thukral, Rishi; Kumar, Sachin; Sadrani, Sannishth M; Baxi, Harsh; Shah, Aditi

    2016-10-01

    Ever since its introduction in 1977, a minimum of few months of period is required for osseointegration to take place after dental implant surgery. With the passage of time and advancements in the fields of dental implant, this healing period is getting smaller and smaller. Immediate loading of dental implants is becoming a very popular procedure in the recent time. Hence, we retrospectively analyzed the various risk factors for the failure of delayed and immediate loaded dental implants. In the present study, retrospective analysis of all the patients was done who underwent dental implant surgeries either by immediate loading procedure or by delayed loading procedures. All the patients were divided broadly into two groups with one group containing patients in which delayed loaded dental implants were placed while other consisted of patients in whom immediate loaded dental implants were placed. All the patients in whom follow-up records were missing and who had past medical history of any systemic diseases were excluded from the present study. Evaluation of associated possible risk factors was done by classifying the predictable factors as primary and secondary factors. All the results were analyzed by Statistical Package for the Social Sciences (SPSS) software. Kaplan-Meier survival analyses and chi-square test were used for assessment of level of significance. In delayed and immediate group of dental implants, mean age of the patients was 54.2 and 54.8 years respectively. Statistically significant results were obtained while comparing the clinical parameters of the dental implants in both the groups while demographic parameters showed nonsignificant correlation. Significant higher risk of dental implant failure is associated with immediate loaded dental implants. Tobacco smoking, shorter implant size, and other risk factors play a significant role in predicting the success and failure of dental implants. Delayed loaded dental implant placement should be preferred

  19. Impact of implant design on primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Wilmes, Benedict; Ottenstreuer, Stephanie; Su, Yu-Yu; Drescher, Dieter

    2008-01-01

    Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability. Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens. We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs. The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.

  20. Impact of Different Surgeons on Dental Implant Failure.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    To assess the influence of several factors on the prevalence of dental implant failure, with special consideration of the placement of implants by different dental surgeons. This retrospective study is based on 2,670 patients who received 10,096 implants at one specialist clinic. Only the data of patients and implants treated by surgeons who had inserted a minimum of 200 implants at the clinic were included. Kaplan-Meier curves were stratified with respect to the individual surgeon. A generalized estimating equation (GEE) method was used to account for the fact that repeated observations (several implants) were placed in a single patient. The factors bone quantity, bone quality, implant location, implant surface, and implant system were analyzed with descriptive statistics separately for each individual surgeon. A total of 10 surgeons were eligible. The differences between the survival curves of each individual were statistically significant. The multivariate GEE model showed the following variables to be statistically significant: surgeon, bruxism, intake of antidepressants, location, implant length, and implant system. The surgeon with the highest absolute number of failures was also the one who inserted the most implants in sites of poor bone and used turned implants in most cases, whereas the surgeon with the lowest absolute number of failures used mainly modern implants. Separate survival analyses of turned and modern implants stratified for the individual surgeon showed statistically significant differences in cumulative survival. Different levels of failure incidence could be observed between the surgeons, occasionally reaching significant levels. Although a direct causal relationship could not be ascertained, the results of the present study suggest that the surgeons' technique, skills, and/or judgment may negatively influence implant survival rates.

  1. The Ukrainian Dental Market: Characteristics of Demand for Services in the Segment of Dental Implantation

    Directory of Open Access Journals (Sweden)

    Slipchenko Tetiana O.

    2017-05-01

    Full Text Available The article is aimed at analyzing the market for dental services in Ukraine in the implantology segment, studying the demand factors for these services and developing a system of measures to manage the demand for dental implantation services. It has been proven that the market for dental services according to a complex of its attributes is more in line with the type of market of monopolistic competition. One of the promising ways of developing the dental market is to transform producers of dental services into the vertically integrated holdings. As one of the specific features of the dental services market is allocated the asymmetry of information, which leads to a conflict between the medical and economic interests of dentists. The price and non-price factors of demand for dental implantation services were determined, the prime cost structure of a dental service was analyzed. The characteristic attributes of a medical service have been defined as consistently defined actions or a complex of actions by medical personnel aimed at prevention, diagnosis, treatment, and rehabilitation, which have a self-contained complete meaning and a certain price.

  2. Immediate versus early non-occlusal loading of dental implants placed flapless in partially edentulous patients. One-year results from a randomised controlled trial.

    Science.gov (United States)

    Merli, Mauro; Merli, Aldo; Bernardelli, Francesco; Lombardini, Francesco; Esposito, Marco

    2008-01-01

    To compare immediate versus early (6 weeks) non-occlusal loading of dental implants placed flapless in partially edentulous patients 1 year after loading. Sixty patients were randomised: 30 to the immediately loaded group and 30 to the early loaded group. In order to be immediately loaded, implants were inserted with a minimum torque of > or = 40Ncm. Implants were fully occlusally loaded after 6 months. Outcome measures were prosthesis and implant failures, and biological and biomechanical complications. Five implants in five patients randomised to the immediately loaded group did not reach the required primary implant stability. Three of these implants (two prostheses) were not immediately loaded. Two patients who were randomised to the early loaded group were immediately loaded erroneously. Implants in five patients of the early loaded group were conventionally loaded. No patient dropped out and there were no failures. Two complications occurred in the early and one in the immediately loaded group (no statistically significant difference), but were solved. The use of a flapless technique for placing dental implants in conjunction with non-occlusal immediate or early loading in selected patients can provide excellent clinical results. No differences were observed when comparing implants that were loaded immediately or early. Therefore, when a high primary implant stability is obtained, it might be preferable to load the implants immediately rather than waiting for a few weeks.

  3. Immediate placement of dental implants in the mandible

    Directory of Open Access Journals (Sweden)

    Gurkar Haraswarupa Puttaraju

    2013-01-01

    Full Text Available This case describes extraction of teeth in the mandibular arch, i.e., 41 42 43 44 45 51 52 53 54 55 56 57 58 (grade two mobility, followed by immediate placement of four dental implants (3i biomet, two in the 45 55 region and two dental implants in 12 21 region. A prefabricated provisional mandibular denture was immediately placed. The purpose of immediate placement was to aid the patient resume his professional duties the next day itself along with esthetic and functional comfort, psychological well-being and most importantly preserving the remaining tissue in a healthy condition.

  4. Attitudes of general dental practitioners towards implant dentistry in an environment with widespread provision of implant therapy.

    Science.gov (United States)

    Lang-Hua, Bich Hue; Lang, Niklaus P; Lo, Edward C M; McGrath, Colman P J

    2013-03-01

    To determine attitudes of general dental practitioners in a community where provision dental implants is a well-known treatment modality; and to identify variations in the attitudes with respect to dentists' factors, training factors and implant provision factors. A questionnaire survey to a random sample of registered dentists In Hong Kong was performed. Attitudes towards implant dentistry with respect to (i) perceived superiority of implant therapy, (ii) perceived outcomes of dental implant therapy, (iii) perceived complications & maintenance issues and (iv) placement issues were ascertained. In addition, information was collected on dentists' factors, training factors and implant provision factors. Variations in attitudes towards implant dentistry were explored in bivariate and regression analyses. Among eligible practitioners (n = 246), the response rate was 46.3%. Dentists perceived implants to be superior to conventional prostheses for the replacement of a single missing posterior tooth (80%, 67) and likewise, for the replacement of a single missing anterior tooth (67%, 67), P attitudes with respect to attitudes exists with respect to dentists' factors (years in practice [P attitudes are not wholly in line with evidence-based knowledge. Variations in their attitudes existed with respect to dentist factors, training and experience issues. © 2012 John Wiley & Sons A/S.

  5. Assessment of blinding success among dental implant clinical trials: A systematic review

    Directory of Open Access Journals (Sweden)

    Jafar Kolahi

    2015-01-01

    Full Text Available Introduction: It is widely believed that blinding is a cornerstone of randomized clinical trials and that significant bias may result from unsuccessful blinding. However, it is not enough to claim that a clinical trial is single- or double-blinded and that assessment of the success of blinding is ideal. The aim of this study was to evaluate the prevalence of assessment of blinding success among dental implant clinical trials and to introduce methods of blinding assessment to the implant research community. Methods: In November 2014, PubMed was searched by blinded and experienced researchers with the query "implant AND (blindFNx01 OR maskFNx01" using the following filters: (1 Article type: clinical trial; (2 Journal categories: dental journals; (3 Field: title/abstract. Consequently, title/abstract was reviewed in all relevant articles to find any attempt to assess the success of blinding in dental implant clinical trials. Results: The PubMed search results yielded 86 clinical trials. The point of interest is that when "blindFNx01 OR maskFNx01" was deleted from the query, the number of results increased to 1688 clinical trials. This shows that only 5% of dental implant clinical trials tried to use blinding. Disappointingly, we could not find any dental implant clinical trial reporting any attempt to assess the success of blinding. Conclusion: The current status of turning a blind eye to unblinding in dental implant clinical trials is not tolerable and needs to be improved. Researchers, protocol reviewers, local ethical committees, journal reviewers, and editors should make a concerted effort to incorporate, report, and publish such information to understand its potential impact on study results.

  6. Management of Patients with Orthopaedic Implants Undergoing Dental Procedures.

    Science.gov (United States)

    Quinn, Robert H; Murray, Jayson N; Pezold, Ryan; Sevarino, Kaitlyn S

    2017-07-01

    The American Academy of Orthopaedic Surgeons, in collaboration with the American Dental Association, has developed Appropriate Use Criteria (AUC) for the Management of Patients with Orthopaedic Implants Undergoing Dental Procedures. Evidence-based information, in conjunction with the clinical expertise of physicians, was used to develop the criteria to improve patient care and obtain best outcomes while considering the subtleties and distinctions necessary in making clinical decisions. The Management of Patients with Orthopaedic Implants Undergoing Dental Procedures AUC clinical patient scenarios were derived from indications of patients with orthopaedic implants presenting for dental procedures, as well as from current evidence-based clinical practice guidelines and supporting literature to identify the appropriateness of the use of prophylactic antibiotics. The 64 patient scenarios and 1 treatment were developed by the writing panel, a group of clinicians who are specialists in this AUC topic. Next, a separate, multidisciplinary, voting panel (made up of specialists and nonspecialists) rated the appropriateness of treatment of each patient scenario using a 9-point scale to designate a treatment as Appropriate (median rating, 7 to 9), May Be Appropriate (median rating, 4 to 6), or Rarely Appropriate (median rating, 1 to 3).

  7. Dental implant survival rate in well-controlled diabetic patients. A systematic review.

    Directory of Open Access Journals (Sweden)

    Heber Arbildo

    2015-12-01

    Full Text Available Background: Dental implants have now become one of the most popular options for replacing a missing tooth. On the other hand, diabetes mellitus is a systemic disease that affects a large part of the population and is generally considered an absolute or relative contraindication to implant therapy. Aim: To determine the survival rate of dental implants in controlled diabetic patients through a systematic review. Material and methods: A systematic search in Pubmed, SciELO and RedALyC databases was performed. The selection criteria were: studies published in the last 10 years, with at least 20 controlled diabetic patients, reporting survival rate and number of implants placed, with follow-up periods equal to or longer than 1 year, including a control group of healthy patients. Methodological quality was analyzed with the follwing scales: Jadad and Downs & Black’s CMQ. Results: Three articles with a follow-up period between 1 and 12 years were analyzed. The overall survival rate of dental implants in diabetic controlled patients was 97.43%. Conclusion: The reviewed literature suggests that survival rate of dental implants in well-controlled diabetic patients is similar to non-diabetic patients.

  8. A comparative study of the effectiveness of early and delayed loading of short tissue-level dental implants with hydrophilic surfaces placed in the posterior section of the mandible-A preliminary study.

    Science.gov (United States)

    Makowiecki, Arkadiusz; Botzenhart, Ute; Seeliger, Julia; Heinemann, Friedhelm; Biocev, Peter; Dominiak, Marzena

    2017-07-01

    The objective of the present study was to compare the primary and secondary stability of tissue-level short dental titanium implants with polished necks and hydrophilic surfaces of two different designs and manufacturers. The first implant system used (SPI ® ELEMENT RC INICELL titanium implants, Thommen Medical AG, Grenchen, Switzerland), allowed functional loading 6 weeks after its placement, whereas the second implant system (RN SLActiv ® tissue-level titanium implants, Straumann GmbH, Fribourg, Germany), was loaded after 15 weeks. The degree of primary and secondary stability was determined using an Osstell ISQ measuring device. Marginal bone loss (MBL) was evaluated radiographically 12 and 24 weeks after implantation and the Wachtel's healing index as well as the patient's satisfaction with the treatment was registered on a VAS scale. The intergroup comparison revealed significant differences in terms of primary stability as well as differences in MBL 3 months after the procedure, but no significant differences could be found after 6 months and for secondary stability. The primary stability was significantly higher for Thommen ® compared to Straumann ® implants. Insertion of short dental implants with a hydrophilic conditioned surface significantly shortens patient treatment time. Copyright © 2017 Elsevier GmbH. All rights reserved.

  9. Stress shielding and fatigue limits of poly-ether-ether-ketone dental implants.

    Science.gov (United States)

    Lee, Woo-Taek; Koak, Jai-Young; Lim, Young-Jun; Kim, Seong-Kyun; Kwon, Ho-Beom; Kim, Myung-Joo

    2012-05-01

    The poly-ether-ether-ketone (PEEK) polymer is of great interest as an alternative to titanium in orthopedics because of its biocompatibility and low elastic modulus. This study evaluated the fatigue limits of PEEK and the effects of the low elastic modulus PEEK in relation to existing dental implants. Compressive loading tests were performed with glass fiber-reinforced PEEK (GFR-PEEK), carbon fiber-reinforced PEEK (CFR-PEEK), and titanium rods. Among these tests, GFR-PEEK fatigue tests were performed according to ISO 14801. For the finite element analysis, three-dimensional models of dental implants and bone were constructed. The implants in the test groups were coated with a 0.5-mm thick and 5-mm long PEEK layer on the upper intrabony area. The strain energy densities (SED) were calculated, and the bone resorption was predicted. The fatigue limits of GFR-PEEK were 310 N and were higher than the static compressive strength of GFR-PEEK. The bone around PEEK-coated implants showed higher levels of SED than the bone in direct contact with the implants, and the wider diameter and stiffer implants showed lower levels of SED. The compressive strength of the GFR-PEEK and CFR-PEEK implants ranged within the bite force of the anterior and posterior dentitions, respectively, and the PEEK implants showed adequate fatigue limits for replacing the anterior teeth. Dental implants with PEEK coatings and PEEK implants may reduce stress shielding effects. Dental implant application of PEEK polymer-fatigue limit and stress shielding. Copyright © 2012 Wiley Periodicals, Inc.

  10. What do patients expect from treatment with Dental Implants? Perceptions, expectations and misconceptions: a multicenter study.

    Science.gov (United States)

    Yao, Jie; Li, Ming; Tang, Hua; Wang, Peng-Lai; Zhao, Yu-Xiao; McGrath, Colman; Mattheos, Nikos

    2017-03-01

    While research in terms of patient-centered care in implant therapy is growing, few studies have investigated patients' initial perceptions prior to consultation with the implant dentist. The aim of this cross-sectional study was to capture patients' initial information level, perceptions, as well as expectations from the implant therapy. A 34-item questionnaire was developed to investigate patients' preoperative information, perceptions and expectations from treatment with Dental Implants. The study was conducted in three locations (Hong Kong, SiChuan and JiangSu) during 2014-2015 with 277 patients. The main information source about implant therapy was the dentist or hygienist for less than half of the patients (n = 113, 42%). About 62.8% of participants considered that they were in general informed about implants, but only 17.7% felt confident with the information they had. More than 30% of the sample appeared to maintain dangerous misperceptions about Dental Implants: "Dental Implants require less care than natural teeth"; "Treatment with Dental Implants is appropriate for all patients with missing teeth"; "Dental Implants last longer than natural teeth"; and "Treatments with Dental Implants have no risks or complications." Patients were divided when asked whether "Dental Implants are as functional as natural teeth" (agreement frequency = 52.7%). Expectations from treatment outcome were commonly high, while there was a significant correlation between the overall mean of perception scores and outcome expectation scores (r = 0.32, P dental team would need to diagnose and correct prior to initiating implant treatment. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. [Dental implant restoration abutment selection].

    Science.gov (United States)

    Bin, Shi; Hao, Zeng

    2017-04-01

    An increasing number of implant restoration abutment types are produced with the rapid development of dental implantology. Although various abutments can meet different clinical demands, the selection of the appropriate abutment is both difficult and confusing. This article aims to help clinicians select the appropriate abutment by describing abutment design, types, and selection criteria.

  12. Evaluation of bone loss in antibacterial coated dental implants: An experimental study in dogs

    International Nuclear Information System (INIS)

    Godoy-Gallardo, Maria; Manzanares-Céspedes, Maria Cristina; Sevilla, Pablo; Nart, José; Manzanares, Norberto; Manero, José M.; Gil, Francisco Javier; Boyd, Steven K.; Rodríguez, Daniel

    2016-01-01

    The aim of this study was to evaluate the in vivo effect of antibacterial modified dental implants in the first stages of peri-implantitis. Thirty dental implants were inserted in the mandibular premolar sites of 5 beagle dogs. Sites were randomly assigned to Ti (untreated implants, 10 units), Ti-Ag (silver electrodeposition treatment, 10 units), and Ti-TSP (silanization treatment, 10 units). Coated implants were characterized by scanning electron microscopy, interferometry and X-ray photoelectron spectroscopy. Two months after implant insertion, experimental peri-implantitis was initiated by ligature placement. Ligatures were removed 2 months later, and plaque formation was allowed for 2 additional months. Clinical and radiographic analyses were performed during the study. Implant-tissue samples were prepared for micro computed tomography, backscattered scanning electron microscopy, histomorphometric and histological analyses and ion release measurements. X-ray, SEM and histology images showed that vertical bone resorption in treated implants was lower than in the control group (P < 0.05). This effect is likely due to the capacity of the treatments to reduce bacteria colonization on the implant surface. Histological analysis suggested an increase of peri-implant bone formation on silanized implants. However, the short post-ligature period was not enough to detect differences in clinical parameters among implant groups. Within the limits of this study, antibacterial surface treatments have a positive effect against bone resorption induced by peri-implantitis. - Highlights: • Dental implants were modified with two antibacterial treatments, silver and TESPSA silanization. • Performance of the modified dental implants was studied in vivo. • Treated implants showed less peri-implant bone resorption. • Decrease in bone resorption was attributed to the antibacterial surface treatments. • Silane treatment enhanced bone regeneration around dental implants.

  13. Evaluation of bone loss in antibacterial coated dental implants: An experimental study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Godoy-Gallardo, Maria [Department of Micro- and Nanotechnology, Technical University of Denmark, Kongens Lyngby (Denmark); Manzanares-Céspedes, Maria Cristina [Unidad de Anatomía y Embriología Humana, Faculty of Dentistry, University of Barcelona, Barcelona (Spain); Sevilla, Pablo [Department of Mechanics, Escola Universitària Salesiana de Sarrià (EUSS), Barcelona (Spain); Nart, José [Department of Periodontology, School of Dentistry, Universitat Internacional de Catalunya, Sant Cugat (Spain); Manzanares, Norberto [Unidad de Anatomía y Embriología Humana, Faculty of Dentistry, University of Barcelona, Barcelona (Spain); Manero, José M. [Biomaterials, Biomechanics and Tissue Engineering Group, Dept. Materials Science and Metallurgical Engineering, Technical University of Catalonia (UPC-BarcelonaTECH), Barcelona (Spain); Centre for Research in NanoEngineering (CRNE), UPC-BarcelonaTECH, Barcelona (Spain); Gil, Francisco Javier [Universitat Internacional de Catalunya, Sant Cugat (Spain); Boyd, Steven K. [McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, Alberta (Canada); Rodríguez, Daniel, E-mail: daniel.rodriguez.rius@upc.edu [Biomaterials, Biomechanics and Tissue Engineering Group, Dept. Materials Science and Metallurgical Engineering, Technical University of Catalonia (UPC-BarcelonaTECH), Barcelona (Spain); Centre for Research in NanoEngineering (CRNE), UPC-BarcelonaTECH, Barcelona (Spain)

    2016-12-01

    The aim of this study was to evaluate the in vivo effect of antibacterial modified dental implants in the first stages of peri-implantitis. Thirty dental implants were inserted in the mandibular premolar sites of 5 beagle dogs. Sites were randomly assigned to Ti (untreated implants, 10 units), Ti-Ag (silver electrodeposition treatment, 10 units), and Ti-TSP (silanization treatment, 10 units). Coated implants were characterized by scanning electron microscopy, interferometry and X-ray photoelectron spectroscopy. Two months after implant insertion, experimental peri-implantitis was initiated by ligature placement. Ligatures were removed 2 months later, and plaque formation was allowed for 2 additional months. Clinical and radiographic analyses were performed during the study. Implant-tissue samples were prepared for micro computed tomography, backscattered scanning electron microscopy, histomorphometric and histological analyses and ion release measurements. X-ray, SEM and histology images showed that vertical bone resorption in treated implants was lower than in the control group (P < 0.05). This effect is likely due to the capacity of the treatments to reduce bacteria colonization on the implant surface. Histological analysis suggested an increase of peri-implant bone formation on silanized implants. However, the short post-ligature period was not enough to detect differences in clinical parameters among implant groups. Within the limits of this study, antibacterial surface treatments have a positive effect against bone resorption induced by peri-implantitis. - Highlights: • Dental implants were modified with two antibacterial treatments, silver and TESPSA silanization. • Performance of the modified dental implants was studied in vivo. • Treated implants showed less peri-implant bone resorption. • Decrease in bone resorption was attributed to the antibacterial surface treatments. • Silane treatment enhanced bone regeneration around dental implants.

  14. The status of undergraduate implant education in dental schools outside the United States.

    Science.gov (United States)

    Seckinger, R J; Weintraub, A M; Berthold, P; Weintraub, G S

    1995-01-01

    Over the past 20 years the incorporation of implant dentistry into academia has been documented in some detail for North American dental schools but has not been pursued on an international level. In June of 1993, we surveyed 51 dental schools outside of the United States affiliated with the University of Pennsylvania School of Dental Medicine's Office of International Relations concerning their teaching involvement with implant dentistry. Results from the 44 (86 percent) responding schools suggest that implant dentistry is being incorporated into predoctoral curriculums. Industrialized countries were more inclined to provide implant education. Insufficient time and the thought that the predoctoral level was not the place for implant dentistry were cited as some of the reasons for not incorporating implant dentistry into the curriculum. Oral surgery, prosthodontics, and periodontics departments developed and administered the implant curriculum. Formats varied among schools with respect to allotted time, curricular placement, laboratory experience, and clinical participation. Didactic material most frequently presented included a historical overview, diagnosis and treatment planning, classification of dental implants, and surgical and prosthetic concepts. Clinical involvement varied from actual implant placement to observation of prosthodontic procedures. Results were categorized based on the TOEFL (Test of English as a Foreign Language) classification of countries in six regions.

  15. The cost of dental implants as compared to that of conventional strategies

    NARCIS (Netherlands)

    van der Wijk, P; Bouma, J; van Waas, MAJ; van Oort, RP; Rutten, FFH

    1998-01-01

    The effectiveness of dental implants is widely studied, especially in terms of their clinical outcomes. However, from the policymaker's point of view, variables other than safety and efficacy such as the costs and effectiveness of dental implants as compared to other treatment alternatives, are

  16. Dental Implant Patients and Their Satisfaction with Treatment.

    Science.gov (United States)

    Tawares, Mary; And Others

    1990-01-01

    The study developed a profile of dental implant patients from 38 private practices to document characteristics of endosseous implant recipients of the past 10 years. Data were then analyzed using multivariate techniques to examine the relationship between these characteristics and patient-reported outcomes. Patients tended to have high incomes and…

  17. The psychosocial impacts of implantation on the dental aesthetics of missing anterior teeth patients.

    Science.gov (United States)

    Chen, P; Yu, S; Zhu, G

    2012-12-01

    The aim of the current study was to investigate the psychosocial impact of dental aesthetics among patients who received anterior implant-supported prostheses. The current study is a cross-sectional evaluation involving 115 individuals who had gone through treatment at the dental clinics of general hospitals. Participants completed the Chinese version of the psychosocial impact of dental aesthetics questionnaire (PIDAQ) before implantation and six months after crown restoration. Basic demographic information was recorded. Six months after implant crown restoration, participants were asked to self-assess their own oral aesthetics compared to before implantation. A total of 106 patients completed the study. PIDAQ scores correlated significantly with the self-assessment of the degree of oral aesthetics. Six months after crown restoration, the two factors (social impact and aesthetic attitude) decreased and the dental self-confidence score increased significantly compared to pre-implantation scores. Gender and education level significantly affected PIDAQ. Anterior implant-supported prostheses significantly affected the patients' psychosocial perception. Implantation of missing anterior teeth can significantly improve patients' negative psychosocial impact of dental aesthetics. Gender and education level are correlated with the degree of improvement. The PIDAQ can be used in assessing the psychosocial effects of implantation in missing anterior teeth.

  18. In vitro biological outcome of laser application for modification or processing of titanium dental implants.

    Science.gov (United States)

    Hindy, Ahmed; Farahmand, Farzam; Tabatabaei, Fahimeh Sadat

    2017-07-01

    There are numerous functions for laser in modern implant dentistry including surface treatment, surface coating, and implant manufacturing. As laser application may potentially improve osseointegration of dental implants, we systematically reviewed the literature for in vitro biological responses to laser-modified or processed titanium dental implants. The literature was searched in PubMed, ISI Web, and Scopus, using keywords "titanium dental implants," "laser," "biocompatibility," and their synonyms. After screening the 136 references obtained, 28 articles met the inclusion criteria. We found that Nd:YAG laser was the most commonly used lasers in the treatment or processing of titanium dental implants. Most of the experiments used cell attachment and cell proliferation to investigate bioresponses of the implants. The most commonly used cells in these assays were osteoblast-like cells. Only one study was conducted in stem cells. These in vitro studies reported higher biocompatibility in laser-modified titanium implants. It seems that laser radiation plays a vital role in cell response to dental implants; however, it is necessary to accomplish more studies using different laser types and parameters on various cells to offer a more conclusive result.

  19. Management of dental implant complications among general dental practitioners in Riyadh, Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Nasser Mansour Assery

    2018-01-01

    Conclusion: Dentists who participated in dental implantology workshops had a higher tendency to answer correctly compared to dentists who were given didactic courses in their undergraduate studies in issues associated with hands-on training. This shows that hands-on training in the undergraduate studies would result in a better understanding of dental implants, its complications, and management.

  20. Crestal bone loss around submerged and nonsubmerged dental implants: A systematic review.

    Science.gov (United States)

    Al Amri, Mohammad D

    2016-05-01

    To my knowledge, there is no systematic review of crestal bone loss (CBL) around submerged and nonsubmerged dental implants. The purpose of this review was to systematically assess CBL around submerged and nonsubmerged dental implants. The addressed focused question was, "Does crestal and subcrestal placement of dental implants influence crestal bone levels?" Databases were searched from 1986 through October 2015 using different combinations of the following keywords: crestal, sub-crestal, bone loss, dental implant, submerged, and nonsubmerged. Reference lists of potentially relevant original and review articles were hand-searched to identify any further studies. Letters to the editor, case reports, commentaries, studies on platform-switched implants, and studies published in languages other than English were excluded. In total, 13 studies (6 human and 7 animal), which were performed at universities, were included. In the human studies, the number of participants ranged from 8 to 84 individuals. The follow-up period ranged from 1 to 5 years. CBL at the test sites ranged from 0.17 mm to 0.9 mm and at control sites from 0.02 mm to 1.4 mm. Five human studies reported no significant difference in CBL around implants placed at the test and control sites. All animal studies were performed in dogs with a mean age ranging from 1 to approximately 2 years. The follow-up period ranged from 2 to 6 months. Four animal studies reported no significant difference in CBL around submerged and nonsubmerged implants. No significant difference in CBL was found around submerged and nonsubmerged dental implants. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. Do sensation differences exist between dental implants and natural teeth?: a meta-analysis.

    Science.gov (United States)

    Higaki, Nobuaki; Goto, Takaharu; Ishida, Yuichi; Watanabe, Megumi; Tomotake, Yoritoki; Ichikawa, Tetsuo

    2014-11-01

    The purpose of this systematic review was to survey evidence pertaining to the sensation differences between natural teeth and osseointegrated dental implants. Using the MEDLINE (online PubMed) database, Cochrane Library, and Scientific Citation index, we performed a systematic search of articles. We used the following search terms: "perception or sensation and dental implant." The systematic review of the extracted articles was performed to see the sensation differences between natural teeth and dental implants. A total of six studies on oral sensation, "tactile sensibility," and "thickness discrimination" were included in the meta-analysis. As to the "tactile sensibility", all studies indicated the threshold levels of the implants were about 4-20 times higher than that of natural teeth. The tactile sensibility of an implant was significantly higher than that of a natural tooth, with an standardized mean difference (SMD) of 8.3619 (95% CI, 6.3920-10.3317) and a P sensation differences between dental implants and natural teeth exist. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Design and manufacture of customized dental implants by using reverse engineering and selective laser melting technology.

    Science.gov (United States)

    Chen, Jianyu; Zhang, Zhiguang; Chen, Xianshuai; Zhang, Chunyu; Zhang, Gong; Xu, Zhewu

    2014-11-01

    Recently a new therapeutic concept of patient-specific implant dentistry has been advanced based on computer-aided design/computer-aided manufacturing technology. However, a comprehensive study of the design and 3-dimensional (3D) printing of the customized implants, their mechanical properties, and their biomechanical behavior is lacking. The purpose of this study was to evaluate the mechanical and biomechanical performance of a novel custom-made dental implant fabricated by the selective laser melting technique with simulation and in vitro experimental studies. Two types of customized implants were designed by using reverse engineering: a root-analog implant and a root-analog threaded implant. The titanium implants were printed layer by layer with the selective laser melting technique. The relative density, surface roughness, tensile properties, bend strength, and dimensional accuracy of the specimens were evaluated. Nonlinear and linear finite element analysis and experimental studies were used to investigate the stress distribution, micromotion, and primary stability of the implants. Selective laser melting 3D printing technology was able to reproduce the customized implant designs and produce high density and strength and adequate dimensional accuracy. Better stress distribution and lower maximum micromotions were observed for the root-analog threaded implant model than for the root-analog implant model. In the experimental tests, the implant stability quotient and pull-out strength of the 2 types of implants indicated that better primary stability can be obtained with a root-analog threaded implant design. Selective laser melting proved to be an efficient means of printing fully dense customized implants with high strength and sufficient dimensional accuracy. Adding the threaded characteristic to the customized root-analog threaded implant design maintained the approximate geometry of the natural root and exhibited better stress distribution and

  3. Implant-retained maxillary overdentures.

    Science.gov (United States)

    Eckert, Steven E; Carr, Alan B

    2004-07-01

    Overdentures supported by osseointegrated implants overcome many of the complications observed with overdentures supported by natural teeth. Dental implants are free of biologic consequences associated with natural teeth, such as dental caries and periodontal disease. Bone undercuts adjacent to implants do not mimic those found adjacent to natural tooth roots. Implants are used to provide predictable retention, support, and stability for overdenture prostheses. When lip or facial support is required, the overdenture is the treatment of choice. Likewise the overdenture may improve phonetic deficiencies associated with alveolar bone loss.

  4. Awareness, knowledge, and attitude of patients toward dental implants - A questionnaire-based prospective study.

    Science.gov (United States)

    Hosadurga, Rajesh; Shanti, Tenneti; Hegde, Shashikanth; Kashyap, Rajesh Shankar; Arunkumar, Suryanarayan Maiya

    2017-01-01

    In developing nations like India awareness and education about dental implants as a treatment modality is still scanty. The study was conducted to determine the awareness, knowledge, and attitude of patients toward dental implants as a treatment modality among the general population and to assess the influence of personality characteristics on accepting dental implants as a treatment modality in general and as well as treatment group. A structured questionnaire-based survey was conducted on 500 randomly selected participants attending the outpatient department. The study was conducted in 2 parts. In the first part of the study, level of awareness, knowledge, and attitude was assessed. In the second part of the study, interactive educational sessions using audiovisual aids were conducted following which a retest was conducted. The participants who agreed to undergo implant treatment were followed up to assess their change in attitude towards dental implants posttreatment. Thus pain, anxiety, functional, and esthetic benefits were measured using visual analog scale. They were further followed up for 1 year to reassess awareness, knowledge, and attitude towards dental implants. A total of 450 individuals completed the questionnaires. Only 106 individuals agreed to participate in the educational sessions and 83 individuals took the retest. Out of these, only 39 individuals chose implants as a treatment option. A significant improvement in the level of information, subjective and objective need for information, was noted after 1 year. In this study, a severe deficit in level of information, subjective and objective need for information towards, dental implants as a treatment modality was noted. In the treatment group, a significant improvement in perception of dental implant as a treatment modality suggests that professionally imparted knowledge can bring about a change in the attitude.

  5. Biocompatibility and anti-microbiological activity characterization of novel coatings for dental implants: A primer for non-biologists

    Directory of Open Access Journals (Sweden)

    Thomas K Monsees

    2016-08-01

    Full Text Available With regard to biocompatibility, the cardinal requirement for dental implants and other medical devices that are in long-term contact with tissue is that the material does not cause any adverse effect to the patient. To warrant stability and function of the implant, proper osseointegration is a further prerequisite. Cells interact with the implant surface as the interface between bulk material and biological tissue. Whereas structuring, deposition of a thin film or other modifications of the surface are crucial parameters in determining favorable adhesion of cells, corrosion of metal surfaces and release of ions can affect cell viability. Both parameters are usually tested using in vitro cytotoxicity and adhesion assays with bone or fibroblasts cells. For bioactive surface modifications, further tests should be considered for biocompatibility evaluation. Depending on the type of modification, this may include analysis of specific cell functions or the determination of antimicrobial activities. The latter is of special importance as bacteria and yeast present in the oral cavity can be introduced during the implantation process and this may lead to chronic infections and implant failure. An antimicrobial coating of the implant is a way to avoid that. This review describes the essential biocompatibility assays for evaluation of new implant materials required by ISO 10993 and also gives an overview on recent test methods for specific coatings of dental implants.

  6. Biocompatibility and anti-microbiological activity characterization of novel coatings for dental implants: A primer for non-biologists

    Science.gov (United States)

    Monsees, Thomas

    2016-08-01

    With regard to biocompatibility, the cardinal requirement for dental implants and other medical devices that are in long-term contact with tissue is that the material does not cause any adverse effect to the patient. To warrant stability and function of the implant, proper osseointegration is a further prerequisite. Cells interact with the implant surface as the interface between bulk material and biological tissue. Whereas structuring, deposition of a thin film or other modifications of the surface are crucial parameters in determining favorable adhesion of cells, corrosion of metal surfaces and release of ions can affect cell viability. Both parameters are usually tested using in vitro cytotoxicity and adhesion assays with bone or fibroblasts cells. For bioactive surface modifications, further tests should be considered for biocompatibility evaluation. Depending on the type of modification, this may include analysis of specific cell functions or the determination of antimicrobial activities. The latter is of special importance as bacteria and yeast present in the oral cavity can be introduced during the implantation process and this may lead to chronic infections and implant failure. An antimicrobial coating of the implant is a way to avoid that. This review describes the essential biocompatibility assays for evaluation of new implant materials required by ISO 10993 and also gives an overview on recent test methods for specific coatings of dental implants.

  7. Which antibiotic regimen prevents implant failure or infection after dental implant surgery? A systematic review and meta-analysis.

    Science.gov (United States)

    Rodríguez Sánchez, Fabio; Rodríguez Andrés, Carlos; Arteagoitia, Iciar

    2018-04-01

    To assess which antibiotic regimen prevents dental implant failures or postoperative infections following dental implant placement. Systematic review and meta-analysis. Pubmed, Cochrane, Science Direct, and EMBASE via OVID were searched up to August 2017. Only randomized controlled clinical trials (RCT) using antibiotics were included. Outcome measures were set on dental implant failures or postoperative infection incidence after dental implant surgery. Three reviewers independently undertook risk of bias assessment and data extraction. Stratified meta-analyses of binary data using fixed-effects models were performed using Stata 14.0. The risk ratio (RR) and 95% confidence interval (CI) were estimated. Nine articles were included corresponding to 15 RCTs. All RCTs tested only oral amoxicillin. Implant-failure analysis: overall RR = 0.53 (P = .005, 95% CI: 0.34-0.82) and overall NNT = 55 (95% CI, 33-167). Single-dose oral amoxicillin preoperatively (SDOAP) is beneficial (RR = 0.50, CI: 0.29-0.86. P = .012), when compared to postoperative oral amoxicillin (POA): RR = 0.60, CI: 0.28-1.30. P = .197. Postoperative-infection analysis: overall RR = 0.76 (P = 0.250, 95% CI: 0.47-1.22). Neither SDOAP (RR = 0.82, CI = 0.46-1.45, P = .488) nor POA (RR = 0.64, CI = 0.27-1.51, P = .309) are beneficial. I 2  = 0.0%, chi-squared tests P ≈ 1. Only SDOAP is effective and efficacious at preventing implant failures, but it was not significant for postoperative infections following dental implant surgeries. Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Titanium Nitride and Nitrogen Ion Implanted Coated Dental Materials

    Directory of Open Access Journals (Sweden)

    David W. Berzins

    2012-07-01

    Full Text Available Titanium nitride and/or nitrogen ion implanted coated dental materials have been investigated since the mid-1980s and considered in various applications in dentistry such as implants, abutments, orthodontic wires, endodontic files, periodontal/oral hygiene instruments, and casting alloys for fixed restorations. Multiple methodologies have been employed to create the coatings, but detailed structural analysis of the coatings is generally lacking in the dental literature. Depending on application, the purpose of the coating is to provide increased surface hardness, abrasion/wear resistance, esthetics, and corrosion resistance, lower friction, as well as greater beneficial interaction with adjacent biological and material substrates. While many studies have reported on the achievement of these properties, a consensus is not always clear. Additionally, few studies have been conducted to assess the efficacy of the coatings in a clinical setting. Overall, titanium nitride and/or nitrogen ion implanted coated dental materials potentially offer advantages over uncoated counterparts, but more investigation is needed to document the structure of the coatings and their clinical effectiveness.

  9. Occlusal stability in shortened dental arches.

    NARCIS (Netherlands)

    Witter, D.J.; Creugers, N.H.J.; Kreulen, C.M.; Haan, A. de

    2001-01-01

    Shortened dental arches consisting of anterior and premolar teeth have been shown to meet oral functional demands. However, the occlusal stability may be at risk as a result of tooth migration. The aim of this nine-year study was to investigate occlusal stability in shortened dental arches as a

  10. Tooth replacements in young adults with severe hypodontia: Orthodontic space closure, dental implants, and tooth-supported fixed dental prostheses. A follow-up study.

    Science.gov (United States)

    Hvaring, Christina L; Øgaard, Bjørn; Birkeland, Kari

    2016-10-01

    Children with severe hypodontia have a substantial impairment of their dental health starting early in life. The purpose of this study was to describe types and locations of substitutes for missing teeth in patients with severe hypodontia and to compare the crown and soft tissue morphologies of orthodontic space closure, dental implants, and tooth-supported fixed dental prostheses for replacing teeth in the anterior region. Fifty patients missing 6 or more teeth and aged 18 years or older (mean age, 25.6 years) took part in a follow-up study. The patients were examined clinically with panoramic radiographs and clinical photographs. Crown and soft tissue variables (mucosal discoloration, crown morphology, color, and papilla index) were compared for orthodontic space closure, dental implant fixtures, and fixed dental prostheses. Dental implants, orthodontic space closure, and retaining deciduous teeth were the most commonly prescribed treatments. Persisting deciduous teeth showed a good survival rate at the follow-up examination. Mucosal discoloration was seen only for implant fixtures and was evident for almost all fixtures in the anterior mandible and two thirds of those in the anterior maxilla. The papilla index scored poorer for both implant fixtures and fixed dental prostheses compared with orthodontic space closure. Dental implants in the anterior region proved to be an inadequate treatment modality in patients with severe hypodontia because of pronounced mucosal discoloration. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  11. Do preoperative antibiotics prevent dental implant complications?

    Science.gov (United States)

    Balevi, Ben

    2008-01-01

    The Cochrane Oral Health Group's Trials Registry, the Cochrane Central Register of Controlled Trials, Medline and Embase were consulted to find relevant work. Searches were made by hand of numerous journals pertinent to oral implantology. There were no language restrictions. Randomised controlled clinical trials (RCT) with a followup of at least 3 months were chosen. Outcome measures were prosthesis failures, implant failures, postoperative infections and adverse events (gastrointestinal, hypersensitivity, etc.). Two reviewers independently assessed the quality and extracted relevant data from included studies. The estimated effect of the intervention was expressed as a risk ratio together with its 95% confidence interval (CI). Numbers-needed-to-treat (NNT) were calculated from numbers of patients affected by implant failures. Meta-analysis was done only if there were studies with similar comparisons that reported the same outcome measure. Significance of any discrepancies between studies was assessed by means of the Cochran's test for heterogeneity and the I2 statistic. Only two RCT met the inclusion criteria. Meta-analysis of these two trials showed a statistically significantly higher number of patients experiencing implant failures in the group not receiving antibiotics (relative risk, 0.22; 95% CI, 0.06-0.86). The NNT to prevent one patient having an implant failure is 25 (95%CI, 13-100), based on a patient implant failure rate of 6% in people not receiving antibiotics. The following outcomes were not statistically significantly linked with implant failure: prosthesis failure, postoperative infection and adverse events (eg, gastrointestinal effects, hypersensitivity). There is some evidence suggesting that 2 g of amoxicillin given orally 1 h preoperatively significantly reduces failures of dental implants placed in ordinary conditions. It remains unclear whether postoperative antibiotics are beneficial, and which is the most effective antibiotic. One dose of

  12. Patients' experiences of dental implant treatment: A literature review of key qualitative studies.

    Science.gov (United States)

    Kashbour, W A; Rousseau, N S; Ellis, J S; Thomason, J M

    2015-07-01

    To identify and summarise the findings of previous qualitative studies relating to patients' experience of dental implant treatment (DIT) at various stages of their implant treatment, by means of textual narrative synthesis. Original articles reporting patients' experience with dental implant were included. A two-stage search of the literature, electronic and hand search identified relevant qualitative studies up to July 2014. An extensive electronic search was conducted of databases including PubMed, Embase, Scopus, Web of Knowledge, Cochrane Database and Google Scholar. Included primary studies (n=10) used qualitative research methods and qualitative analysis to investigate patients' experiences with dental implants treatment. While the growing interest in implant treatment for the replacement of missing dentition is evident, it is essential to investigate patients' perceptions of different aspects of implant treatment. This textual narrative synthesis conducted to review qualitative studies which provided insight into patients' experience of two types of implant prostheses namely ISOD (implant-supported overdenture) and FISP (fixed implant supported prostheses). Primary reviewed studies tended to include samples of older patients with more extensive tooth loss, and to focus on experiences prior to and post-treatment rather than on the treatment period itself. Findings across reviewed studies (n=10) suggested that patients with FISP thought of implant treatment as a process of 'normalisation'(1) and believed that such implant restorations could be similar to natural teeth, whereas patients with ISOD focused more on the functional and social advantages of their implant treatment. The growing interest in qualitative research is evident in several branches of clinical dentistry and dental implantology is not an exception. Qualitative studies concerning the patients account of their experience of dental implants is however limited. The aim of this review is to

  13. Periodontal ligament formation around different types of dental titanium implants. I. The self-tapping screw type implant system

    DEFF Research Database (Denmark)

    Warrer, K; Karring, T; Gotfredsen, K

    1993-01-01

    The aim of this study was to determine if a periodontal ligament can form around self-tapping, screw type titanium dental implants. Implants were inserted in contact with the periodontal ligament of root tips retained in the mandibular jaws of 7 monkeys. In each side of the mandible, 1 premolar......, a periodontal ligament can form on self-tapping, screw type titanium dental implants in areas where a void is present between the surrounding bone and the implant at the time of insertion....... and 2 molars were removed in such a manner that in approximately half the cases, the root tips were retained. Following healing, the experimental areas were examined on radiographs, and sites were selected for the insertion of the implants, so that every second implant would have a close contact...

  14. Accuracy of digital impression in dental implants: A literature review

    OpenAIRE

    Sudabe Kulivand; Maryam Moslemion

    2016-01-01

    Restoration of dental implants remains one of the most challenging aspects of implant dentistry. Although it is not clear whether prosthetic misfit could affect osseointegration, mechanical complications of implant-supported prostheses can be avoided by achieving a good passive fit between the framework and the implants. Passive fit is a difficult concept to define. Obtaining absolute passive fit of the prosthetic framework on implants has been reported to be nearly impossible. Because of ...

  15. Nanomodified Peek Dental Implants: Bioactive Composites and Surface Modification—A Review

    Directory of Open Access Journals (Sweden)

    Shariq Najeeb

    2015-01-01

    Full Text Available Purpose. The aim of this review is to summarize and evaluate the relevant literature regarding the different ways how polyetheretherketone (PEEK can be modified to overcome its limited bioactivity, and thereby making it suitable as a dental implant material. Study Selection. An electronic literature search was conducted via the PubMed and Google Scholar databases using the keywords “PEEK dental implants,” “nano,” “osseointegration,” “surface treatment,” and “modification.” A total of 16 in vivo and in vitro studies were found suitable to be included in this review. Results. There are many viable methods to increase the bioactivity of PEEK. Most methods focus on increasing the surface roughness, increasing the hydrophilicity and coating osseoconductive materials. Conclusion. There are many ways in which PEEK can be modified at a nanometer level to overcome its limited bioactivity. Melt-blending with bioactive nanoparticles can be used to produce bioactive nanocomposites, while spin-coating, gas plasma etching, electron beam, and plasma-ion immersion implantation can be used to modify the surface of PEEK implants in order to make them more bioactive. However, more animal studies are needed before these implants can be deemed suitable to be used as dental implants.

  16. Evaluation of stabilization techniques for ion implant processing

    Science.gov (United States)

    Ross, Matthew F.; Wong, Selmer S.; Minter, Jason P.; Marlowe, Trey; Narcy, Mark E.; Livesay, William R.

    1999-06-01

    With the integration of high current ion implant processing into volume CMOS manufacturing, the need for photoresist stabilization to achieve a stable ion implant process is critical. This study compares electron beam stabilization, a non-thermal process, with more traditional thermal stabilization techniques such as hot plate baking and vacuum oven processing. The electron beam processing is carried out in a flood exposure system with no active heating of the wafer. These stabilization techniques are applied to typical ion implant processes that might be found in a CMOS production process flow. The stabilization processes are applied to a 1.1 micrometers thick PFI-38A i-line photoresist film prior to ion implant processing. Post stabilization CD variation is detailed with respect to wall slope and feature integrity. SEM photographs detail the effects of the stabilization technique on photoresist features. The thermal stability of the photoresist is shown for different levels of stabilization and post stabilization thermal cycling. Thermal flow stability of the photoresist is detailed via SEM photographs. A significant improvement in thermal stability is achieved with the electron beam process, such that photoresist features are stable to temperatures in excess of 200 degrees C. Ion implant processing parameters are evaluated and compared for the different stabilization methods. Ion implant system end-station chamber pressure is detailed as a function of ion implant process and stabilization condition. The ion implant process conditions are detailed for varying factors such as ion current, energy, and total dose. A reduction in the ion implant systems end-station chamber pressure is achieved with the electron beam stabilization process over the other techniques considered. This reduction in end-station chamber pressure is shown to provide a reduction in total process time for a given ion implant dose. Improvements in the ion implant process are detailed across

  17. Zirconia Dental Implants: Investigation of Clinical Parameters, Patient Satisfaction, and Microbial Contamination.

    Science.gov (United States)

    Holländer, Jens; Lorenz, Jonas; Stübinger, Stefan; Hölscher, Werner; Heidemann, Detlef; Ghanaati, Shahram; Sader, Robert

    2016-01-01

    In recent years, dental implants made from zirconia have been further developed and are considered a reliable treatment method for replacing missing teeth. The aim of this study was to analyze dental implants made from zirconia regarding their clinical performance compared with natural teeth (control). One hundred six zirconia implants in 38 adults were analyzed in a clinical study after 1 year of loading. The plaque index (PI), bleeding on probing (BOP), probing pocket depth (PPD), probing attachment level (PAL), and creeping or recession (CR/REC) of the gingiva were detected and compared with natural control teeth (CT). Furthermore, the papilla index (PAP), Periotest values (PTV), microbial colonization of the implant/dental sulcus fluid, and patient satisfaction were assessed. The survival rate was 100%. No statistical significance was observed between implants and teeth regarding BOP, PPD, and PAL. A statistical significance was detected regarding PI and CR/REC with significantly less plaque accumulation and recession in the study group. Mean PAP was 1.76 ± 0.55, whereas the mean PTV was -1.31 ± 2.24 (range from -5 to +6). A non-statistically significant higher colonization of periodontitis/peri-implantitis bacteria was observed in the implant group. The questionnaire showed that the majority of the patients were satisfied with the overall treatment. One-piece zirconia dental implants exhibited similar clinical results (BOP, PPD, and PAL) compared with natural teeth in regard to adhesion of plaque (PI) and creeping attachment (CR/REC); zirconia implants performed even better. The favorable results for PAL and CR/REC reflect the comparable low affinity of zirconia for plaque adhesion. Patient satisfaction indicated a high level of acceptance for zirconia implants. However, a long-term follow-up is needed to support these findings.

  18. Effect on Bone Architecture of Marginal Grooves in Dental Implants Under Occlusal Loaded Conditions in Beagle Dogs.

    Science.gov (United States)

    Kato, Hatsumi; Kuroshima, Shinichiro; Inaba, Nao; Uto, Yusuke; Sawase, Takashi

    2018-02-01

    The aim of this study was to clarify whether marginal grooves on dental implants affect osseointegration, bone structure, and the alignment of collagen fibers to determine bone quality under loaded conditions. Anodized Ti-6Al-4V alloy dental implants, with and without marginal grooves (test and control implants, respectively), were used (3.7 × 8.0 mm). Fourth premolars and first molars of 6 beagle mandibles were extracted. Two control and test implants were placed in randomly selected healed sites at 12 weeks after tooth extraction. Screw-retained single crowns for first molars were fabricated. Euthanasia was performed at 8 weeks after the application of occlusal forces. Implant marginal bone level, bone to implant contact (BIC), bone structure around dental implants, and the alignment of collagen fibers determining bone quality were analyzed. The marginal bone level in test implants was significantly higher than that in control implants. Occlusal forces significantly increased BIC in test implants ( P = .007), whereas BIC did not change in control implants, irrespective of occlusal forces ( P = .303). Moreover, occlusal forces significantly increased BIC in test implants compared with control implants ( P = .032). Additionally, occlusal forces preferentially aligned collagen fibers in test implants, but not control implants. Hence, marginal grooves on dental implants have positive effects on increased osseointegration and adapted bone quality based on the preferential alignment of collagen fibers around dental implants under loaded conditions.

  19. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study.

    NARCIS (Netherlands)

    Tabassum, A.; Meijer, G.J.; Wolke, J.G.C.; Jansen, J.A.

    2010-01-01

    OBJECTIVE: The aim of this biomechanical study was to assess the interrelated effect of both surface roughness and surgical technique on the primary stability of dental implants. MATERIAL AND METHODS: For the experiment, 160 screw-designed implants (Biocomp), with either a machined or an etched

  20. Retrospective analysis of dental implants placed and restored by advanced prosthodontic residents.

    Science.gov (United States)

    Barias, Pamela A; Lee, Damian J; Yuan, Judy Chia-Chun; Sukotjo, Cortino; Campbell, Stephen D; Knoernschild, Kent L

    2013-02-01

    The purposes of this retrospective clinical review were to: (1) describe the demographics of implant patients, types of implant treatment and implant-supported prostheses in an Advanced Education in Prosthodontic Program, (2) evaluate the survival rate of dental implants placed by prosthodontic residents from 2006 to 2008, and (3) analyze the relationship between resident year of training and implant survival rate. All patients who received dental implants placed by prosthodontic residents from January 2006 to October of 2008 in the Advanced Prosthodontic Program at the University of Illinois at Chicago College of Dentistry were selected for this study. Age, gender, implant diameter, length, implant locations, surgical and restorative detail, and year of prosthodontic residency training were collected and analyzed. Life-table and Kaplan-Meier survival analyses were performed based on implants overall, locations, year of training, and use of a computer-generated surgical guide. A Logrank statistic was performed between implant survival and year of prosthodontic residency training, location, and use of computer-generated surgical guide (α= 0.05). Three hundred and six implants were placed, and of these, seven failed. Life-table and Kaplan-Meier analyses computed a cumulative survival rate (CSR) of 97% for overall implants and implants placed with a computer-generated surgical guide. No statistical difference was found in implant survival rates as a function of year of training (P= 0.85). Dental implants placed by prosthodontic residents had a CSR comparable to previously published studies by other specialties. The year of prosthodontic residency training and implant failure rate did not have any significant relationship. © 2012 by the American College of Prosthodontists.

  1. Non-Destructive Analysis of Basic Surface Characteristics of Titanium Dental Implants Made by Miniature Machining

    Science.gov (United States)

    Babík, Ondrej; Czán, Andrej; Holubják, Jozef; Kameník, Roman; Pilc, Jozef

    2016-12-01

    One of the most best-known characteristic and important requirement of dental implant is made of biomaterials ability to create correct interaction between implant and human body. The most implemented material in manufacturing of dental implants is titanium of different grades of pureness. Since most of the implant surface is in direct contact with bone tissue, shape and integrity of said surface has great influence on the successful osseointegration. Among other characteristics of titanium that predetermine ideal biomaterial, it shows a high mechanical strength making precise machining miniature Increasingly difficult. The article is focused on evaluation of the resulting quality, integrity and characteristics of dental implants surface after machining.

  2. Effects of Untreated Periodontitis on Osseointegration of Dental Implants in a Beagle Dog Model.

    Science.gov (United States)

    Lee, Daehyun; Sohn, Byungjin; Kim, Kyoung Hwa; Kim, Sungtae; Koo, Ki-Tae; Kim, Tae-Il; Seol, Yang-Jo; Lee, Yong-Moo; Rhyu, In-Chul; Ku, Young

    2016-10-01

    There have been previous studies on the relationship between periodontitis and peri-implantitis, but limited information is available on how periodontitis affects osseointegration and wound healing of newly placed dental implants adjacent to natural teeth. The objective of the present experiment is to evaluate healing around dental implants adjacent to teeth with untreated experimental periodontitis. The study included six male beagle dogs. Scaling and plaque control procedures were performed on three dogs (control group). In the other three dogs (experimental group), retraction cords and ligature wires were placed subgingivally around all premolars and the first molars. Induced experimental periodontitis was confirmed after 3 months. Each control or experimental group was divided into two subgroups depending on the timing of implant placement (immediate/delayed). Twelve dental implants (two implants for each dog) were placed immediately, and the other 12 dental implants (two implants for each dog) were placed 2 months after extraction. The animals were sacrificed 2 months after implant placement. Histologic and histometric analyses were performed. Four implants (three from the immediate placement group and one from the delayed placement group) failed in the experimental group. There were significant differences in the percentage of bone-to-implant contact and marginal bone volume density between the control and experimental groups. Both parameters were significantly lower in the experimental group than in the control group (P implants is associated with a higher failure rate compared with delayed placement. Untreated experimental periodontitis was correlated with compromised osseointegration in the implants with delayed placement.

  3. A study on the resistance at bone-implant interface during implant insertion in a cadaver goat jaw model

    Directory of Open Access Journals (Sweden)

    Goutam Das

    2016-01-01

    Full Text Available Background: The aim of the study is to determine the resistance at bone-implant interface during insertion of dental implant. Materials and Methods: Freshly procured cadaver goat mandibles were collected from slaughterhouses. Four dental implants of two different diameters were inserted into osteotomized sites of the goat mandibles. The gradual changes in resonance frequency (RF were recorded in RF analyzer for the five consecutive turns of implant insertion. Results and Observations: RF was found to be positively correlated with diameter of dental implants. Conclusion: RF analysis can be used to determine the type of resistance the implant faces during insertion and the kind of bone density through which it passes. It gives a forecast of expected initial stability.

  4. Fatigue failure of dental implants in simulated intraoral media.

    Science.gov (United States)

    Shemtov-Yona, K; Rittel, D

    2016-09-01

    Metallic dental implants are exposed to various intraoral environments and repetitive loads during service. Relatively few studies have systematically addressed the potential influence of the environment on the mechanical integrity of the implants, which is therefore the subject of this study. Four media (groups) were selected for room temperature testing, namely dry air, saliva substitute, same with 250ppm of fluoride, and saline solution (0.9%). Monolithic Ti-6Al-4V implants were loaded until fracture, using random spectrum loading. The study reveals that the only aggressive medium of all is the saline solution, as it shortens significantly the spectrum fatigue life of the implants. The quantitative scanning electron fractographic analysis indicates that all the tested implants grew fatigue cracks of similar lengths prior to catastrophic fracture. However, the average crack growth rate in the saline medium was found to largely exceed that in other media, suggesting a decreased fracture toughness. The notion of a characteristic timescale for environmental degradation was proposed to explain the results of our spectrum tests that blend randomly low and high cycle fatigue. Random spectrum fatigue testing is powerful technique to assess and compare the mechanical performance of dental implants for various designs and/or environments. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. In vivo osseointegration of dental implants with an antimicrobial peptide coating.

    Science.gov (United States)

    Chen, X; Zhou, X C; Liu, S; Wu, R F; Aparicio, C; Wu, J Y

    2017-05-01

    This study aimed to evaluate the in vivo osseointegration of implants with hydrophobic antimicrobial GL13K-peptide coating in rabbit femoral condyles by micro-CT and histological analysis. Six male Japanese Rabbits (4 months old and weighing 2.5 kg each) were included in this study. Twelve implants (3.75 mm wide, 7 mm long) were randomly distributed in two groups, with six implants in the experimental group coated with GL13K peptide and six implants in the control group without surface coating. Each implant in the test and the control group was randomly implanted in the left or right side of femoral condyles. On one side randomly-selected of the femur, each rabbit received a drill that was left without implant as control for the natural healing of bone. After 3 weeks of healing radiographic evaluation of the implant sites was taken. After 6 weeks of healing, rabbits were sacrificed for evaluation of the short-term osseointegration of the dental implants using digital radiography, micro-CT and histology analysis. To perform evaluation of osseointegration, implant location and group was double blinded for surgeon and histology/radiology researcher. Two rabbits died of wound infection in sites with non-coated implants 2 weeks after surgery. Thus, at least four rabbits per group survived after 6 weeks of healing. The wounds healed without suppuration and inflammation. No implant was loose after 6 weeks of healing. Radiography observations showed good osseointegration after 3 and 6 weeks postoperatively, which proved that the tissues followed a natural healing process. Micro-CT reconstruction and analysis showed that there was no statistically significant difference (P > 0.05) in volume of bone around the implant between implants coated with GL13K peptide and implants without coating. Histomorphometric analysis also showed that the mineralized bone area was no statistically different (P > 0.05) between implants coated with GL13K peptide and

  6. Prosthetic Rehabilitation of a Patient with Mandibular Resection Prosthesis Using Mini Dental Implants (MDIs) – Case Report

    OpenAIRE

    Vojvodić, Denis; Čelebić, Asja; Mehulić, Ketij; Žabarović, Domagoj

    2012-01-01

    Physical disfigurement and functional impairments associated with facial trauma are a challenge to a prosthodontist, because even novel sophisticated surgical reconstructive techniques fail to provide adequate support for dental resection prosthesis. Therefore, different endosseous implants are often used as prosthesis-supporting elements. Manufacturers of dental implants have recently presented mini dental implants (MDIs) with diameter of only 1.8–2.4 mm. These implants allow very suitable p...

  7. Dental implant customization using numerical optimization design and 3-dimensional printing fabrication of zirconia ceramic.

    Science.gov (United States)

    Cheng, Yung-Chang; Lin, Deng-Huei; Jiang, Cho-Pei; Lin, Yuan-Min

    2017-05-01

    This study proposes a new methodology for dental implant customization consisting of numerical geometric optimization and 3-dimensional printing fabrication of zirconia ceramic. In the numerical modeling, exogenous factors for implant shape include the thread pitch, thread depth, maximal diameter of implant neck, and body size. Endogenous factors are bone density, cortical bone thickness, and non-osseointegration. An integration procedure, including uniform design method, Kriging interpolation and genetic algorithm, is applied to optimize the geometry of dental implants. The threshold of minimal micromotion for optimization evaluation was 100 μm. The optimized model is imported to the 3-dimensional slurry printer to fabricate the zirconia green body (powder is bonded by polymer weakly) of the implant. The sintered implant is obtained using a 2-stage sintering process. Twelve models are constructed according to uniform design method and simulated the micromotion behavior using finite element modeling. The result of uniform design models yields a set of exogenous factors that can provide the minimal micromotion (30.61 μm), as a suitable model. Kriging interpolation and genetic algorithm modified the exogenous factor of the suitable model, resulting in 27.11 μm as an optimization model. Experimental results show that the 3-dimensional slurry printer successfully fabricated the green body of the optimization model, but the accuracy of sintered part still needs to be improved. In addition, the scanning electron microscopy morphology is a stabilized t-phase microstructure, and the average compressive strength of the sintered part is 632.1 MPa. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Assessment of the Survival of Dental Implants in Irradiated Jaws ...

    African Journals Online (AJOL)

    frequency of dental implant placement in irradiated jaws from. 2002 to 2008 in India. Table 2 ..... Linsen SS, Martini M, Stark H. Long-term results of endosteal implants following radical oral ... Oral Health 2015:5;1-6. 21. Visch LL, van Waas MA ...

  9. Mini dental implants retaining mandibular overdentures: A dental practice-based retrospective analysis.

    Science.gov (United States)

    Schwindling, Franz Sebastian; Schwindling, Franz-Peter

    2016-07-01

    The purpose of this study was to assess the survival of mini dental implants (MDI) and to measure prosthetic maintenance needs in a dental practice-based setting. Patients with mandibular removable dentures were provided with MDI to improve denture retention. Complications and maintenance were analyzed by use of patient records and evaluated with Kaplan-Meier curves and the log rank test at a significance level of 0.05. Ninety-nine MDI were placed in 25 patients (mean age: 72 years). Two MDI fractured during placement and eight implants failed during the first weeks. No more implants were lost for up to seven years, resulting in 92% survival. Implant survival differed significantly depending on whether the maxilla was provided with complete dentures (94.9%) or with partial dentures (81%). All prostheses were in use at the time of data extraction. Denture base fractures were observed in six cases, an incidence of fractures of 24%. Some minor intervention was necessary: one resin tooth fractured, retention rings were changed in five cases, and repeated relining was required for 16% of the dentures. After mid-term observation, survival of MDI was good. However, the incidence of denture base fractures and of minor prosthetic complications should not be under-estimated. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Evaluation of the effects of different sand particles that used in dental implant roughened for osseointegration.

    Science.gov (United States)

    Yurttutan, Mehmet Emre; Keskin, Ahmet

    2018-03-20

    Successful dental implant treatment is directly related to osseointegration. In achieving osseointegration, the surface property of the implant is of great importance. Sandblasting is the most commonly used basic method for modifying the surface. Many companies use different sand particles for surface roughening and claim their sand is the best. This leads clinicians to mix their minds in product selection. In this study, we tried to find the appropriate sand material by working objectively without praising any brand. We believe that the results of the study will help clinicians choose the right dental implant. In this study, machined-surfaced implants and implants sandblasted with Aluminum oxide (Al 2 O 3 ), Titanium dioxide (TiO 2 ) and Silicon dioxide (SiO 2 ) were compared via biomechanical testing. For the study, four 2 year-old sheep, weighing 45 kilograms (kg), were used. Eight implants (Al 2 O 3 , TiO 2 , and SiO 2 sandblasted implants and machined-surfaced implants), each with different surface characteristics, were inserted into the bilateral tibia of each sheep under general anesthesia. Results of the initial Resonance Frequency Analysis (RFA) were recorded just after implant insertion. The sheep were then randomly divided into two groups, each with 2 sheep, to undergo either a 1-month or a 3-month assessment. At the end of the designated evaluation period, RFA and removal torque tests were performed. Although there were no statistically significant differences between the groups, the implants sandblasted with Al 2 O 3 showed a higher Implant Stability Quotient (ISQ) and removal torque value at the end of the 1st and 3rd month. In short, the results of the study demonstrate that Aluminum oxide is superior to other sand particles.

  11. Modulation of human dermal microvascular endothelial cell and human gingival fibroblast behavior by micropatterned silica coating surfaces for zirconia dental implant applications

    International Nuclear Information System (INIS)

    Laranjeira, Marta S; Carvalho, Ângela; Ferraz, Maria Pia; Monteiro, Fernando Jorge; Pelaez-Vargas, Alejandro; Hansford, Derek; Coimbra, Susana; Costa, Elísio; Santos-Silva, Alice; Fernandes, Maria Helena

    2014-01-01

    Dental ceramic implants have shown superior esthetic behavior and the absence of induced allergic disorders when compared to titanium implants. Zirconia may become a potential candidate to be used as an alternative to titanium dental implants if surface modifications are introduced. In this work, bioactive micropatterned silica coatings were produced on zirconia substrates, using a combined methodology of sol–gel processing and soft lithography. The aim of the work was to compare the in vitro behavior of human gingival fibroblasts (HGFs) and human dermal microvascular endothelial cells (HDMECs) on three types of silica-coated zirconia surfaces: flat and micropatterned (with pillars and with parallel grooves). Our results showed that cells had a higher metabolic activity (HGF, HDMEC) and increased gene expression levels of fibroblast-specific protein-1 (FSP-1) and collagen type I (COL I) on surfaces with pillars. Nevertheless, parallel grooved surfaces were able to guide cell growth. Even capillary tube-like networks of HDMEC were oriented according to the surface geometry. Zirconia and silica with different topographies have shown to be blood compatible and silica coating reduced bacteria adhesion. All together, the results indicated that microstructured bioactive coating seems to be an efficient strategy to improve soft tissue integration on zirconia implants, protecting implants from peri-implant inflammation and improving long-term implant stabilization. This new approach of micropatterned silica coating on zirconia substrates can generate promising novel dental implants, with surfaces that provide physical cues to guide cells and enhance their behavior. (paper)

  12. Compliance with Supportive Periodontal Treatment in Patients with Dental Implants.

    Science.gov (United States)

    Hu, Kai-Fang; Lin, Ying-Chu; Ho, Kun-Yen; Chou, Yu-Hsiang

    The need for dental implants is increasing, and supportive periodontal treatment can achieve long-term success and prevent peri-implantitis. Contributing factors to noncompliance with long-term scheduled supportive periodontal treatment remain unclear. To investigate whether demographic and clinical characteristics are associated with noncompliance, the authors analyzed data for patients who had received dental implants. The authors recruited patients participating in a supportive periodontal treatment program after receiving permanent prostheses on implants placed from 2005 to 2013. Demographic data and dental treatment histories were collected. Compliance was defined as a record of participation in a standard supportive periodontal treatment program for at least 1 year. The chi-square test, log-rank test, Kaplan-Meier survival curve, and Cox proportional hazards model were used for statistical analysis. The study included 120 patients (259 implants, 60% compliance). The two groups (compliant and noncompliant) differed significantly in frequency distributions for sex (P = .0017), educational level (P = .0325), and histories of substance use (P = .0016), periodontitis (P = .0005), and root planing or flap surgery (P = .0002). The Kaplan-Meier survival curves and log-rank test showed that increases in cumulative continuation rates were significantly associated with male sex (P = .0025); body mass index ≥ 24 kg/m² (P = .0093); and a history of periodontitis (P implant placement, root planing or flap surgery was the crucial factor in determining compliance with supportive periodontal treatment. However, well-designed large-scale studies with a larger sample size are needed to confirm the findings of this study.

  13. Immediate provisionalization of dental implants placed in healed alveolar ridges and extraction sockets: a 5-year prospective evaluation.

    Science.gov (United States)

    Cooper, Lyndon F; Reside, Glenn J; Raes, Filiep; Garriga, Joan Soliva; Tarrida, Luis Giner; Wiltfang, Jörg; Kern, Matthias; De Bruyn, Hugo

    2014-01-01

    This 5-year prospective multicenter study compared implant survival and success, peri-implant health and soft tissue responses, crestal bone level stability, and complication rates following immediate loading of single OsseoSpeed implants placed in anterior maxillary healed ridges or extraction sockets. Individuals requiring anterior tooth replacement with single implants were treated and immediately provisionalized. Definitive all-ceramic crowns were placed at 12 weeks. Implant survival, bone levels, soft tissue levels, and peri-implant health were monitored for 5 years. One hundred thirteen patients received implants in fresh sockets (55) and healed ridges (58). After 5 years, 45 and 49 patients remained for evaluation, respectively. During the first year, three implants failed in the extraction socket group (94.6% survival) and one implant failed in the healed ridge group (98.3% survival); this difference was not significant. No further implant failures were recorded. After 5 years, the interproximal crestal bone levels were located a mean of 0.43 ± 0.63 mm and 0.38 ± 0.62 mm from the reference points of implants in sockets and healed ridges (not a significant difference). In both groups, papillae increased over time and peri-implant mucosal zenith positions were stable from the time of definitive crown placement in sockets and healed ridges. Compared to flap surgery for implants in healed ridges, flapless surgery resulted in increased peri-implant mucosal tissue dimension (average, 0.78 ± 1.34 mm vs 0.19 ± 0.79 mm). After 5 years, the bone and soft tissue parameters that characterize implant success and contribute to dental implant esthetics were similar following the immediate provisionalization of implants in sockets and healed ridges. The overall tissue responses and reported implant survival support the immediate provisionalization of dental implants in situations involving healed ridges and, under ideal circumstances, extraction sockets.

  14. Biomechanics and load resistance of small-diameter and mini dental implants: a review of literature.

    Science.gov (United States)

    Hasan, Istabrak; Bourauel, Christoph; Mundt, Torsten; Stark, Helmut; Heinemann, Friedhelm

    2014-02-01

    In recent years, the application of small-diameter and mini dental implants to support removable and fixed prosthesis has dramatically increased. However, the success of these implants under functional biting forces and the reaction of the bone around them need to be analyzed. This review was aimed to present studies that deal with the fatigue life of small-diameter and mini dental implants under normal biting force, and their survival rate. The numerical and experimental studies concluded that an increase in the risk of bone damage or implant failure may be assumed in critical clinical situations and implants with <3 mm diameter have a risk of fracture in clinical practice. The survival rate of the small-diameter and mini dental implants over 5 years was 98.3-99.4%.

  15. Removal of a Dental Implant Displaced into the Maxillary Sinus by Means of the Bone Lid Technique

    Directory of Open Access Journals (Sweden)

    Pietro Fusari

    2013-01-01

    Full Text Available Background. Rehabilitation of edentulous jaws with implant-supported prosthesis has become a common practice among oral surgeons in the last three decades. This therapy presents a very low incidence of complications. One of them is the displacement of dental implants into the maxillary sinus. Dental implants, such as any other foreign body into the maxillary sinus, should be removed in order to prevent sinusitis. Methods. In this paper, we report a case of dental implant migrated in the maxillary sinus and removed by means of the bone lid technique. Results and Conclusion. The migration of dental implants into the maxillary sinus is rarely reported. Migrated implants should be considered for removal in order to prevent possible sinusal diseases. The implant has been removed without any complications, confirming the bone lid technique to be safe and reliable.

  16. Fracaso en los implantes dentales: Fibrointegración. Reporte de caso clínico

    Directory of Open Access Journals (Sweden)

    Iris Luz Santís Chamorro

    2014-06-01

    Full Text Available  ResumenLa rehabilitación con implantes dentales en los pacientes con edentulismo parcial o total posee amplias indicaciones que se ven limitadas por factores anatómicos y biológicos. La oseointegración surge como un hecho descubierto entre la adaptación biológica del hueso a la superficie del titanio del implante (interfase hueso-implante por lo que se afirma que el motivo de fracaso de la mayoría de los sistemas de implantes es que éstos se encapsulen en un tejido de cicatrización fibroso (fibrointegración mal diferenciado lo que crea movilidad, que lleva a reacciones en la mucosa y finalmente a la pérdida. El objetivo del presente artículo es promover la presentación de casos clínicos de pacientes con fracaso de implantes dentales, con el ánimo de esclarecer las posibles causas y los factores coadyuvantes de dicho fracaso, y así mejorar los resultados en implantología. (Duazary 2008; 115-120AbstractThe rehabilitation with dental implants in the patients with partial absence or total of teeth possesses extensive indications that are seen limited by biological and anatomical factors. The oseointegration arises like a discovered fact among the biological adaptation of the bone to the surface of the titanic of the implant (interface bone-implant for which it is affirmed that the motive of failure of the majority of the systems of implants is that these it self envelop in a scar formation of fibrous tissue (Fibrointegration badly differentiated what creates mobility, that carries to reactions in the mucous membrane and finally to the loss. The objective of the present article is to promote the presentation of patients' clinical cases with failure of dental implants, with the intention of clarifying the possible reasons and the helping factors of the above mentioned failure, and this way to improve the results in implantology.Key Words: Fibrointegration; oseointegration; dentals implants; interface; implants failure.

  17. Maxillary implant-retained partial overdenture with Dolder bar attachment: a clinical report.

    Science.gov (United States)

    Kim, Hyeongil; Buhite, Robert J; Monaco, Edward A

    2015-03-01

    This article describes a technique for maintaining a maxillary Kennedy III partial removable dental prosthesis design in a patient who had non-restorable failing abutments by replacing the abutments with dental implants. Two implants were placed immediately after extraction of the abutment teeth in the anterior maxilla. After the implants were fully integrated, a Dolder bar attachment was fitted onto the implants. A new maxillary partial removable dental prosthesis was fabricated using the implants and the remaining natural teeth as abutments to restore function and esthetics. With the aid of dental implants, this Kennedy III maxillary removable dental prosthesis design could provide additional retention and support by promoting cross-arch stability and tissue, implant and tooth support. The patient's satisfaction was significantly increased.

  18. Dimensional soft tissue changes following soft tissue grafting in conjunction with implant placement or around present dental implants: a systematic review.

    Science.gov (United States)

    Poskevicius, Lukas; Sidlauskas, Antanas; Galindo-Moreno, Pablo; Juodzbalys, Gintaras

    2017-01-01

    To systematically review changes in mucosal soft tissue thickness and keratinised mucosa width after soft tissue grafting around dental implants. An electronic literature search was conducted of the MEDLINE database published between 2009 and 2014. Sequential screenings at the title, abstract, and full-text levels were performed. Clinical human studies in the English language that had reported changes in soft tissue thickness or keratinised mucosa width after soft tissue grafting at implant placement or around a present implant at 6-month follow-up or longer were included. The search resulted in fourteen articles meeting the inclusion criteria: Six of them reported connective tissue grafting around present dental implants, compared to eight at the time of implant placement. Better long-term soft tissue thickness outcomes were reported for soft tissue augmentation around dental implants (0.8-1.4 mm), compared with augmentation at implant placement (-0.25-1.43 mm). Both techniques were effective in increasing keratinised tissue width: at implant placement (2.5 mm) or around present dental implants (2.33-2.57 mm). The present systematic review discovered that connective tissue grafts enhanced keratinised mucosa width and soft tissue thickness for an observation period of up to 48 months. However, some shrinkage may occur, resulting in decreases in soft tissue, mostly for the first three months. Further investigations using accurate evaluation methods need to be done to evaluate the appropriate time for grafting. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Long-term success of dental implants in patients with head and neck cancer after radiation therapy.

    Science.gov (United States)

    Curi, M M; Condezo, A F B; Ribeiro, K D C B; Cardoso, C L

    2018-06-01

    The purpose of this study was to analyze the long-term success and factors potentially influencing the success of dental implants placed in patients with head and neck cancer who underwent radiation therapy with a minimum total dose of 50Gy during the years 1995-2010. Thirty-five patients (169 dental implants) were included in this study. Data on demographic characteristics, tumour type, radiation therapy, implant sites, implant dimensions, and hyperbaric oxygen therapy (HBOT) were obtained from the medical records and analyzed. Implant survival was estimated using Kaplan-Meier survival curves. Seventy-nine dental implants were placed in the maxilla and 90 in the mandible. The mean follow-up after implant installation was 7.4 years (range 0.3-14.7 years). The overall 5-year survival rate for all implants was 92.9%. Sex (Pradiation therapy delivery (P=0.005) had a statistically significant influence on implant survival. Age, time of implantation after irradiation, implant brand and dimensions, and HBOT had no statistically significant influence on implant survival. Osseointegrated dental implants can be used successfully in the oral rehabilitation of patients with head and neck cancer with a history of radiation therapy. Risk factors such as sex and the mode of radiation therapy delivery can affect implant survival. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. The development of a composite bone model for training on placement of dental implants.

    Science.gov (United States)

    Alkhodary, Mohamed Ahmed; Abdelraheim, Abdelraheim Emad Eldin; Elsantawy, Abd Elaleem Hassan; Al Dahman, Yousef Hamad; Al-Mershed, Mohammed

    2015-04-01

    It takes a lot of training on patients for both undergraduate to develop clinical sense as regards to the placement of dental implants in the jaw bones, also, the models provided by the dental implant companies for training are usually made of strengthened synthetic foams, which are far from the composition, and tactile sense provided by natural bone during drilling for clinical placement of dental implants. This is an in-vitro experimental study which utilized bovine femur bone, where the shaft of the femur provided the surface compact layer, and the head provided the cancellous bone layer, to provide a training model similar to jaw bones macroscopic anatomy. Both the compact and cancellous bone samples were characterized using mechanical compressive testing. The elastic moduli of the cancellous and cortical femur bone were comparable to those of the human mandible, and the prepared training model provided a more lifelike condition during the drilling and placement of dental implants. The composite bone model developed simulated the macroscopic anatomy of the jaw bones having a surface layer of compact bone, and a core of cancellous bone, and provided a better and a more natural hands-on experience for placement of dental implants as compared to plastic models made of polyurethane.

  1. Finite element analysis of the stress distributions in peri-implant bone in modified and standard-threaded dental implants

    Directory of Open Access Journals (Sweden)

    Serkan Dundar

    2016-01-01

    Full Text Available The aim of this study was to examine the stress distributions with three different loads in two different geometric and threaded types of dental implants by finite element analysis. For this purpose, two different implant models, Nobel Replace and Nobel Active (Nobel Biocare, Zurich, Switzerland, which are currently used in clinical cases, were constructed by using ANSYS Workbench 12.1. The stress distributions on components of the implant system under three different static loadings were analysed for the two models. The maximum stress values that occurred in all components were observed in FIII (300 N. The maximum stress values occurred in FIII (300 N when the Nobel Replace implant is used, whereas the lowest ones, in the case of FI (150 N loading in the Nobel Active implant. In all models, the maximum tensions were observed to be in the neck region of the implants. Increasing the connection between the implant and the bone surface may allow more uniform distribution of the forces of the dental implant and may protect the bone around the implant. Thus, the implant could remain in the mouth for longer periods. Variable-thread tapered implants can increase the implant and bone contact.

  2. Survival Rate of Dental Implants in Patients with History of Periodontal Disease: A Retrospective Cohort Study.

    Science.gov (United States)

    Correia, Francisco; Gouveia, Sónia; Felino, António Campos; Costa, Ana Lemos; Almeida, Ricardo Faria

    To evaluate the differences between the survival rates of implants placed in patients with no history of periodontal disease (NP) and in patients with a history of chronic periodontal disease (CP). A retrospective cohort study was conducted in which all consenting patients treated with dental implants in a private clinic in Oporto, Portugal, from November 2, 2002 through February 11, 2011 were included. All patients were treated consecutively by the same experimental operator. This study aimed to analyze how the primary outcomes (presence of disease, time of placement, and time of loading) and the secondary outcomes (severity-generalized periodontitis, brand, implant length, prosthesis type, prosthesis metal-ceramic extension) influence the survival rate of dental implants. The survival analysis was performed through the Kaplan-Meier method, and the equality of survival distributions for all groups was tested with the log-rank test with a significance level of .05 for all comparisons. The sample consisted of 202 patients (47% NP and 53% CP) and 689 implants (31% NP and 69% CP). The survival rate in the NP and CP groups showed no statistically significant differences (95.8% versus 93.1%; P ≥ .05). Implants were lost before loading in 54.9% of the cases. The majority of the implants were lost in the first year and stabilized after the second year. Survival rates in the NP and CP patients showed no statistically significant differences when comparing the following factors: subclassification of the disease, implant brands, implant length (short/standard), type of prosthesis, extension of the prosthesis metal-ceramic, and time of placement and loading (P ≥ .05). This work disclosed no statistically significant differences in terms of survival rates when compared with the control group. Placing implants in patients with a history of periodontal disease appears to be viable and safe.

  3. Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement.

    Science.gov (United States)

    Yunus, Barunawaty

    2011-06-01

    This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.

  4. Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement

    Energy Technology Data Exchange (ETDEWEB)

    Yunus, Barunawaty [Faculty of Dentistry, Hasanuddin University, Makassar (Malaysia)

    2011-06-15

    This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.

  5. Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement

    International Nuclear Information System (INIS)

    Yunus, Barunawaty

    2011-01-01

    This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.

  6. Retrospective analysis of 56 edentulous dental arches restored with 344 single-stage implants using an immediate loading fixed provisional protocol: statistical predictors of implant failure.

    Science.gov (United States)

    Kinsel, Richard P; Liss, Mindy

    2007-01-01

    The purpose of this retrospective study was to evaluate the effects of implant dimensions, surface treatment, location in the dental arch, numbers of supporting implant abutments, surgical technique, and generally recognized risk factors on the survival of a series of single-stage Straumann dental implants placed into edentulous arches using an immediate loading protocol. Each patient received between 4 and 18 implants in one or both dental arches. Periapical radiographs were obtained over a 2- to 10-year follow-up period to evaluate crestal bone loss following insertion of the definitive metal-ceramic fixed prostheses. Univariate tests for failure rates as a function of age ( or = 60 years), gender, smoking, bone grafting, dental arch, surface type, anterior versus posterior, number of implants per arch, and surgical technique were made using Fisher exact tests. The Cochran-Armitage test for trend was used to evaluate the presence of a linear trend in failure rates regarding implant length and implant diameter. Logistic regression modeling was used to determine which, if any, of the aforementioned factors would predict patient and implant failure. A significance criterion of P = .05 was utilized. Data were collected for 344 single-stage implants placed into 56 edentulous arches (39 maxillae and 17 mandibles) of 43 patients and immediately loaded with a 1-piece provisional fixed prosthesis. A total of 16 implants failed to successfully integrate, for a survival rate of 95.3%. Increased rates of failure were associated with reduced implant length, placement in the posterior region of the jaw, increased implant diameter, and surface treatment. Implant length emerged as the sole significant predictor of implant failure. In this retrospective analysis of 56 consecutively treated edentulous arches with multiple single-stage dental implants loaded immediately, reduced implant length was the sole significant predictor of failure.

  7. Mandibular implant-supported overdentures: attachment systems, and number and locations of implants--Part I.

    Science.gov (United States)

    Warreth, Abdulhadi; Alkadhimi, Aslam Fadel; Sultan, Ahmed; Byrne, Caroline; Woods, Edel

    2015-01-01

    The use of dental implants in replacing missing teeth is an integral part of restorative dental treatment. Use of conventional complete dentures is associated with several problems such as lack of denture stability, support and retention. However, when mandibular complete dentures were used with two or more implants, an improvement in the patients' psychological and social well-being could be seen. There is general consensus that removable implant-supported overdentures (RISOs) with two implants should be considered as the first-choice standard of care for an edentulous mandible. This treatment option necessitates the use of attachment systems that connect the complete denture to the implant. Nevertheless, each attachment system has its inherent advantages and disadvantages, which should be considered when choosing a system. The first part of this article provides an overview on options available to restore the mandibular edentulous arch with dental implants. Different types of attachment systems, their features and drawbacks are also reviewed.

  8. Surface treatment of dental implants with high- power pulsed ion beams

    International Nuclear Information System (INIS)

    Shulov, V.A.; Nochovnaya, N.A.; Remnev, G.E.; Ivanov, S.Y.; Lomakin, M.V.

    2001-01-01

    The objective of the present research is development of HPPIB technology for surface processing of compact components with a complex shape. The surface state of the dental implants from titanium alloys before and after irradiation and long time operation was investigated by Auger electron spectroscopy, scanning electron microscopy, X-ray structural analysis, optical metallography methods. It is shown that the homogeneous state in the surface layer of titanium alloys is formed due to the irradiation (carbon ions and protons, energy of ions is equal to 300 keV, density of ion energy in a pulse achieves 1-5 J/cm 2 ). This state is characterized by a low amount of the impurities and a fine dispersion structure formed as a result of high speed crystallization. Thus, HPPIB irradiation of the dental implants leads to formation of developed micro relief and the decrease of impurities content on the surface. As a result, this treatment allows one to achieve a good cohesion between the implants and a body tissue. The latter allows the conclusion that biocompatibility of the dental titanium implants produced by can be improved using HPPIB treatment

  9. Dissolution ad uptake of cadmium from dental gold solder alloy implants

    International Nuclear Information System (INIS)

    Bergman, B.; Bergman, M.; Soeremark, R.

    1977-01-01

    Pure metallic cadmium was irradiated by means of thermal neutrons. The irradiated cadmium ( 115 Cd) was placed in bags of gold foil and the bags were implanted subcutaneously in the neck region of mice. Two and 3 d respectively after implantation the mice were killed, the bags removed and the animals subjected to whole-body autoradiography. The autoradiograms revealed an uptake of 115 Cd in liver and kidney. In another experiment specimens of a cadmium-containing dental gold solder alloy, a cadmium-free dental casting gold alloy and soldered assemblies made of these two alloys were implanted subcutaneously in the neck region of mice. The animals were killed after 6 months; cadmium analysis showed significant increases in the cadmium concentration in liver and kidney of those mice which had been given implants of gold solder alloy. The study clearly shows that due to electrochemical corrosion cadmium can be released from implants and accumulated in the kidneys and the liver. (author)

  10. Dissolution and uptake of cadmium from dental gold solder alloy implants

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, B; Bergman, M; Soeremark, R [Umeaa Univ. (Sweden); Karolinska Institutet, Stockholm (Sweden))

    1977-01-01

    Pure metallic cadmium was irradiated by means of thermal neutrons. The irradiated cadmium (/sup 115/Cd) was placed in bags of gold foil and the bags were implanted subcutaneously in the neck region of mice. Two and 3 d respectively after implantation the mice were killed, the bags removed and the animals subjected to whole-body autoradiography. The autoradiograms revealed an uptake of /sup 115/Cd in liver and kidney. In another experiment specimens of a cadmium-containing dental gold solder alloy, a cadmium-free dental casting gold alloy and soldered assemblies made of these two alloys were implanted subcutaneously in the neck region of mice. The animals were killed after 6 months; cadmium analysis showed significant increases in the cadmium concentration in liver and kidney of those mice which had been given implants of gold solder alloy. The study clearly shows that due to electrochemical corrosion cadmium can be released from implants and accumulated in the kidneys and the liver.

  11. Assessment of the survival of dental implants in irradiated jaws ...

    African Journals Online (AJOL)

    Background: In patients undergoing head and neck surgery for various pathologic conditions, implants are one of the best restorative options and are increasing widely used. Therefore, we evaluated the success of dental implants in the irradiated jaws of patients following treatment of oral cancer oral cancer treated patients ...

  12. Bruxism and dental implant failures: a multilevel mixed effects parametric survival analysis approach.

    Science.gov (United States)

    Chrcanovic, B R; Kisch, J; Albrektsson, T; Wennerberg, A

    2016-11-01

    Recent studies have suggested that the insertion of dental implants in patients being diagnosed with bruxism negatively affected the implant failure rates. The aim of the present study was to investigate the association between the bruxism and the risk of dental implant failure. This retrospective study is based on 2670 patients who received 10 096 implants at one specialist clinic. Implant- and patient-related data were collected. Descriptive statistics were used to describe the patients and implants. Multilevel mixed effects parametric survival analysis was used to test the association between bruxism and risk of implant failure adjusting for several potential confounders. Criteria from a recent international consensus (Lobbezoo et al., J Oral Rehabil, 40, 2013, 2) and from the International Classification of Sleep Disorders (International classification of sleep disorders, revised: diagnostic and coding manual, American Academy of Sleep Medicine, Chicago, 2014) were used to define and diagnose the condition. The number of implants with information available for all variables totalled 3549, placed in 994 patients, with 179 implants reported as failures. The implant failure rates were 13·0% (24/185) for bruxers and 4·6% (155/3364) for non-bruxers (P bruxism was a statistically significantly risk factor to implant failure (HR 3·396; 95% CI 1·314, 8·777; P = 0·012), as well as implant length, implant diameter, implant surface, bone quantity D in relation to quantity A, bone quality 4 in relation to quality 1 (Lekholm and Zarb classification), smoking and the intake of proton pump inhibitors. It is suggested that the bruxism may be associated with an increased risk of dental implant failure. © 2016 John Wiley & Sons Ltd.

  13. Evaluation of possible prognostic factors for the success, survival, and failure of dental implants.

    Science.gov (United States)

    Geckili, Onur; Bilhan, Hakan; Geckili, Esma; Cilingir, Altug; Mumcu, Emre; Bural, Canan

    2014-02-01

    To analyze the prognostic factors that are associated with the success, survival, and failure rates of dental implants. Data including implant sizes, insertion time, implant location, and prosthetic treatment of 1656 implants have been collected, and the association of these factors with success, survival, and failure of implants was analyzed. The success rate was lower for short and maxillary implants. The failure rate of maxillary implants exceeded that of mandibular implants, and the failure rate of implants that were placed in the maxillary anterior region was significantly higher than other regions. The failure rates of implants that were placed 5 years ago or more were higher than those that were placed later. Anterior maxilla is more critical for implant loss than other sites. Implants in the anterior mandible show better success compared with other locations, and longer implants show better success rates. The learning curve of the clinician influences survival and success rates of dental implants.

  14. Bruxism: overview of current knowledge and suggestions for dental implants planning.

    Science.gov (United States)

    Manfredini, Daniele; Bucci, Marco Brady; Sabattini, Vincenzo Bucci; Lobbezoo, Frank

    2011-10-01

    Bruxism is commonly considered a detrimental motor activity, potentially causing overload of the stomatognathic structures and representing a risk factor for dental implant survival. The available literature does not provide evidence-based guidelines for the management of bruxers undergoing implant-retained restorations. The present paper reviewed current concepts on bruxism etiology, diagnosis and management, underlining its effects on dental implants in an attempt to provide clinically useful suggestions based on scientifically sound data. Unfortunately, very little data exists on the subject of a cause-and-effect relationship between bruxism and implant failure, to the point that expert opinions and cautionary approaches are still considered the best available sources for suggesting good practice indicators. By including experimental literature data on the effects of different types of occlusal loading on peri-implant marginal bone loss along with data from studies investigating the intensity of the forces transmitted to the bone itself during tooth-clenching and tooth-grinding activities, the authors were able to compile the suggestions presented here for prosthetic implant rehabilitations in patients with bruxism.

  15. Stability Development of Immediately Loaded Hybrid Self-Tapping Implants Inserted in the Posterior Maxilla: 1-Year Results of a Randomized Controlled Trial.

    Science.gov (United States)

    Todorovic, Vladimir S; Vasovic, Miroslav; Beetge, Mia-Michaela; van Zyl, Andre W; Kokovic, Vladimir

    2017-02-01

    The objective of the present study was to elucidate stability development of immediately loaded hybrid self-tapping implants inserted in the posterior maxilla. Forty-eight hybrid self-tapping implants with a chemically modified surface (∅4.1; length: 8 mm) were inserted bilaterally in the maxillary first and second premolar and first molar sites of 8 patients. In each patient, both sides of the maxilla were assigned randomly to either immediate (IL) or early (EL) loading group. Implant stability was evaluated by means of resonance frequency analysis immediately after implant placement and after 1, 2, 3, 4, 5, 6, 12, 26, and 52 weeks. High values of primary stability were found in both groups (71.91 ± 6.52 implant stability quotient [ISQ] in IL group; 73.87 ± 6.5 ISQ in EL group), with significant differences between the groups at the different time points. Initial decrease in stability was observed between the first and fifth weeks in the IL group and between the first and third weeks for the EL group. In the IL group 1 implant was removed after 3 weeks due to lack of stability. Early results of this study showed the ability of hybrid self-tapping dental implants with a chemically modified surface to achieve sufficient primary stability and to maintain high values of secondary implant stability in bone type 3 and 4, even when loaded immediately. Minimal alterations in stability were observed for both investigated groups, but the EL group showed faster recovery after an initial drop in stability.

  16. Assessment of Surface Area Characteristics of Dental Implants with Gradual Bioactive Surface Treatment

    Science.gov (United States)

    Czan, Andrej; Babík, Ondrej; Miklos, Matej; Záušková, Lucia; Mezencevová, Viktória

    2017-10-01

    Since most of the implant surface is in direct contact with bone tissue, shape and integrity of said surface has great influence on successful osseointegration. Among other characteristics that predetermine titanium of different grades of pureness as ideal biomaterial, titanium shows high mechanical strength making precise miniature machining increasingly difficult. Current titanium-based implants are often anodized due to colour coding. This anodized layer has important functional properties for right usage and also bio-compatibility of dental implants. Physical method of anodizing and usage of anodizing mediums has a significant influence on the surface quality and itself functionality. However, basic requirement of the dental implant with satisfactory properties is quality of machined surface before anodizing. Roughness, for example, is factor affecting of time length of anodizing operation and so whole productivity. The paper is focused on monitoring of surface and area characteristics, such as roughness or surface integrity after different cutting conditions of miniature machining of dental implants and their impact on suitability for creation of satisfactory anodized layer with the correct biocompatible functional properties.

  17. A Survey of the Knowledge of Dental Implants as a Choice in ...

    African Journals Online (AJOL)

    Background: Dental implantology is fast becoming a specialty in the field of dentistry. Within the last five decades, dentistry appears to have recorded its most significant advancement in the field of dental implantology. With dental implants, missing teeth can now be replaced with stable, comfortable and natural-looking and ...

  18. Comparison of two multiaxial fatigue models applied to dental implants

    Directory of Open Access Journals (Sweden)

    JM. Ayllon

    2015-07-01

    Full Text Available This paper presents two multiaxial fatigue life prediction models applied to a commercial dental implant. One model is called Variable Initiation Length Model and takes into account both the crack initiation and propagation phases. The second model combines the Theory of Critical Distance with a critical plane damage model to characterise the initiation and initial propagation of micro/meso cracks in the material. This paper discusses which material properties are necessary for the implementation of these models and how to obtain them in the laboratory from simple test specimens. It also describes the FE models developed for the stress/strain and stress intensity factor characterisation in the implant. The results of applying both life prediction models are compared with experimental results arising from the application of ISO-14801 standard to a commercial dental implant.

  19. Piezosurgery in Bone Augmentation Procedures Previous to Dental Implant Surgery: A Review of the Literature

    Science.gov (United States)

    Magrin, Gabriel Leonardo; Sigua-Rodriguez, Eder Alberto; Goulart, Douglas Rangel; Asprino, Luciana

    2015-01-01

    The piezosurgery has been used with increasing frequency and applicability by health professionals, especially those who deal with dental implants. The concept of piezoelectricity has emerged in the nineteenth century, but it was applied in oral surgery from 1988 by Tomaso Vercellotti. It consists of an ultrasonic device able to cut mineralized bone tissue, without injuring the adjacent soft tissue. It also has several advantages when compared to conventional techniques with drills and saws, such as the production of a precise, clean and low bleed bone cut that shows positive biological results. In dental implants surgery, it has been used for maxillary sinus lifting, removal of bone blocks, distraction osteogenesis, lateralization of the inferior alveolar nerve, split crest of alveolar ridge and even for dental implants placement. The purpose of this paper is to discuss the use of piezosurgery in bone augmentation procedures used previously to dental implants placement. PMID:26966469

  20. A novel implantation model for evaluation of bone healing response to dental implants: the goat iliac crest.

    NARCIS (Netherlands)

    Schouten, C.; Meijer, G.J.; Beucken, J.J.J.P van den; Spauwen, P.H.M.; Jansen, J.A.

    2010-01-01

    OBJECTIVES: Despite the availability of numerous animal models for testing the biological performance of dental and orthopedic implants, the selection of a suitable model is complex. This paper presents a new model for objective and standardized evaluation of bone responses to implants using the

  1. The influence of dental implants in periapical and panoramic radiographs and cone beam computed tomography images: a clinical study.

    Science.gov (United States)

    Felix, Rafael Perdomo; Shinkai, Rosemary Sadami Arai; Rockenbach, Maria Ivete Bolzan

    2018-01-01

    The aim of this study was to analyze the influence of dental implants on the radiographic density of the peri-implant region in tomographic and radiographic examinations. A sample of 21 dental implants from 10 patients with Brånemark-protocol prostheses was evaluated based on postoperative control images, including periapical radiography (paralleling technique), panoramic radiography, and cone beam computed tomography (CBCT). The density means of 6 defined areas near dental implants were calculated and compared considering their locations and the different imaging examinations. The CBCT examinations showed significantly different densities among the measured areas (P implants in all the examinations: CBCT (127.88 and 120.71), panoramic (106.51 and 106.09), and periapical (120.32). The sagittal CBCT images were measured in 2 different sections, and in both sections those areas closer to implants showed mean densities that were significantly higher than means from more distant areas (P implant region confirmed the interference of dental implants in radiographic and tomographic images. CBCT images suffered the greatest interference from dental implants.

  2. Assessment of Myeloperoxidase and Nitric Levels around Dental Implants and Natural Teeth as a Marker of Inflammation: A Comparative Study.

    Science.gov (United States)

    Kulkarni, Gayithri H; Jadhav, Prashant; Kulkarni, Kiran; Shinde, Sachin V; Patil, Yojana B; Kumar, Manish

    2016-11-01

    Dental implants form the mainstay of dental treatment involving rehabilitation of missing teeth. One of the major concerns for the clinicians doing dental implants is the postsurgical failure of dental implants. Success of dental implants is dependent upon the skills of the surgeon and the amount and quality of the bone remaining at the edentulous area where dental implant has to be placed. Myeloperoxidase (MPO) and nitrites are few of the enzymes and molecules which are said to be altered in inflammation. However, their exact role in the inflammatory processes around natural tooth and dental implant is still unclear. Hence we comparatively evaluated the levels of MPO and nitrites in the areas around the dental implants and natural teeth. The present study comprises 42 patients who underwent prosthetic rehabilitation by dental implants from 2011 to 2014. Depth of probing value (DP), score of plaque index (SPI), gingival index (GI), and index of gingival bleeding time (GBT) were evaluated for the assessment of the periimplant soft tissue changes. Assessment of inflammation around the dental implant surface and around natural tooth was done based on the readings of these parameters. For the measurement of the MPO levels, spectrophotometric MPO assay was used. All the results were analyzed by Statistical Package for the Social Sciences (SPSS) software. The mean plaque index values were 1.56 and 0.97 in periodontitis cases of natural teeth and inflamed cases of dental implants respectively. While comparing mean plaque index, mean probing depth, and mean gingival bleeding index in between the two groups, significant difference was obtained. Mean MPO concentration in periodontitis and gingivitis cases in natural teeth were 0.683 and 0.875 U/μL, while in inflamed dental implant cases, the mean value was 0.622 U/μL. While comparing the total MPO levels, total nitrite levels, and total nitrite concentration in between two study groups, significant difference was obtained

  3. Survival of Dental Implants Placed in Grafted and Nongrafted Bone: A Retrospective Study in a University Setting.

    Science.gov (United States)

    Tran, Duong T; Gay, Isabel C; Diaz-Rodriguez, Janice; Parthasarathy, Kavitha; Weltman, Robin; Friedman, Lawrence

    2016-01-01

    To compare dental implant survival rates when placed in native bone and grafted sites. Additionally, risk factors associated with dental implant loss were identified. This study was based on the hypothesis that bone grafting has no effect on implant survival rates. A retrospective chart review was conducted for patients receiving dental implants at the University of Texas, School of Dentistry from 1985 to 2012. Exclusion criteria included patients with genetic diseases, radiation and chemotherapy, or an age less than 18 years. To avoid misclassification bias, implants were excluded if bone grafts were only done at the same time of placement. Data on age, sex, tobacco use, diabetes, osteoporosis, anatomical location of the implant, implant length and width, bone graft, and professional maintenance were collected for analysis. A total of 1,222 patients with 2,729 implants were included. The cumulative survival rates at 5 and 10 years were 92% and 87% for implants placed in native bone and 90% and 79% for implants placed in grafted bone, respectively. The results from multivariate analysis (Cox regression) indicated no significant difference in survival between the two groups; having maintenance therapy after implant placement reduced the failure rate by 80% (P dental implant survival rate when implants were placed in native bone or bone-grafted sites. Smoking and lack of professional maintenance were significantly related to increased implant loss.

  4. An alternative method to record rising temperatures during dental implant site preparation: a preliminary study using bovine bone

    Directory of Open Access Journals (Sweden)

    Domenica Laurito

    2010-12-01

    Full Text Available Overheating is constantly mentioned as a risk factor for bone necrosis that could compromise the dental implant primary stability. Uncontrolled thermal injury can result in a fibrous tissue, interpositioned at the implant-bone interface, compromising the long-term prognosis. The methods used to record temperature rise include either direct recording by thermocouple instruments or indirect estimating by infrared thermography. This preliminary study was carried out using bovine bone and a different method of temperatures rising estimation is presented. Two different types of drills were tested using fluoroptic thermometer and the effectiveness of this alternative temperature recording method was evaluated.

  5. Soft tissue wound healing around teeth and dental implants.

    Science.gov (United States)

    Sculean, Anton; Gruber, Reinhard; Bosshardt, Dieter D

    2014-04-01

    To provide an overview on the biology and soft tissue wound healing around teeth and dental implants. This narrative review focuses on cell biology and histology of soft tissue wounds around natural teeth and dental implants. The available data indicate that: (a) Oral wounds follow a similar pattern. (b) The tissue specificities of the gingival, alveolar and palatal mucosa appear to be innately and not necessarily functionally determined. (c) The granulation tissue originating from the periodontal ligament or from connective tissue originally covered by keratinized epithelium has the potential to induce keratinization. However, it also appears that deep palatal connective tissue may not have the same potential to induce keratinization as the palatal connective tissue originating from an immediately subepithelial area. (d) Epithelial healing following non-surgical and surgical periodontal therapy appears to be completed after a period of 7–14 days. Structural integrity of a maturing wound between a denuded root surface and a soft tissue flap is achieved at approximately 14-days post-surgery. (e) The formation of the biological width and maturation of the barrier function around transmucosal implants requires 6–8 weeks of healing. (f) The established peri-implant soft connective tissue resembles a scar tissue in composition, fibre orientation, and vasculature. (g) The peri-implant junctional epithelium may reach a greater final length under certain conditions such as implants placed into fresh extraction sockets versus conventional implant procedures in healed sites. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Mechanical and Spectroscopic Analysis of Retrieved/Failed Dental Implants

    Directory of Open Access Journals (Sweden)

    Umer Daood

    2017-11-01

    Full Text Available The purpose of this study was to examine surface alterations and bone formation on the surface of failed dental implants (Straumann [ST] and TiUnite [TiUn] removed due to any biological reason. In addition, failure analysis was performed to test mechanical properties. Dental implants (n = 38 from two manufacturers were collected and subjected to chemical cleaning. The presence of newly formed hydroxyapatite bone around failed implants was evaluated using micro-Raman spectroscopy. Scanning electron microscopy was used to identify surface defects. Mechanical testing was performed using a Minneapolis servo-hydraulic system (MTS along with indentation using a universal testing machine and average values were recorded. A statistical analysis of mechanical properties was done using an unpaired t test, and correlation between observed defects was evaluated using Chi-square (p = 0.05. Apatite-formation was evident in both implants, but was found qualitatively more in the ST group. No significant difference was found in indentation between the two groups (p > 0.05. The percentage of “no defects” was significantly lower in the ST group (71%. Crack-like and full-crack defects were observed in 49% and 39% of TiUn. The ST group showed 11,061 cycles to failure as compared with 10,021 cycles in the TiUnite group. Implant failure mechanisms are complex with a combination of mechanical and biological reasons and these factors are variable with different implant systems.

  7. B-Cure Laser Dental Pro technology for prevention and treatment of peri-implant mucositis

    Science.gov (United States)

    Gileva, O. S.; Libik, T. V.; Chuprakov, M. A.; Yakov, A. Y.; Mirsaeva, F. Z.

    2017-09-01

    Oral mucositis (OM) is the severe inflammation, lesioning and ulceration of the epithelia, accompanied by bleeding and intensive pain. OM is a common complication of dental implantation. Low-level laser therapy (LLLT) has been found to enhance the repair and healing of epithelia. The aim of this study was to evaluate the effectiveness of preventive and treatment use of LLLT (B-Cure Laser Dental Pro technology in original author's techniques) in the patients who have undergone dental implantation. Simple blind randomized prospective one-center comparative placebo-controlled clinical trial is carried out on the group of 30 partially edentulous patients. It is proved that the use of LLLT before and after installation of dental implants provides: 1) reliable reduction (by 3.5 times) of the frequency of implication and intensity of pain in the first days after operation; 2) reduction (by 3.3-3.7 times) of frequency, duration and intensity of local edematous and inflammatory processes in peri-implant zone and facial soft tissue edema; 3) effective prophylaxis of postoperative sensory, paresthesia and neurologic disturbances in maxillofacial area.

  8. Does Bruxism Contribute to Dental Implant Failure? A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Zhou, Yi; Gao, Jinxia; Luo, Le; Wang, Yining

    2016-04-01

    Bruxism was usually considered as a contraindication for oral implanting. The causal relationship between bruxism and dental implant failure was remained controversial in existing literatures. This meta-analysis was performed to investigate the relationship between them. This review conducted an electronic systematic literature search in MEDLINE (PubMed) and EmBase in November 2013 without time and language restrictions. Meanwhile, a hand searching for all the relevant references of included studies was also conducted. Study information extraction and methodological quality assessments were accomplished by two reviewers independently. A discussion ensued if any disagreement occurred, and unresolved issues were solved by consulting a third reviewer. Methodological quality was assessed by using the Newcastle-Ottawa Scale tool. Odds ratio (OR) with 95% confidence interval (CI) was pooled to estimate the relative effect of bruxism on dental implant failures. Fixed effects model was used initially; if the heterogeneity was high, random effects model was chosen for meta-analysis. Statistical analyses were carried out by using Review Manager 5.1. In this meta-analysis review, extracted data were classified into two groups based on different units. Units were based on the number of prostheses (group A) and the number of patients (group B). In group A, the total pooled OR of bruxers versus nonbruxers for all subgroups was 4.72 (95% CI: 2.66-8.36, p = .07). In group B, the total pooled OR of bruxers versus nonbruxers for all subgroups was 3.83 (95% CI: 2.12-6.94, p = .22). This meta-analysis was performed to evaluate the relationship between bruxism and dental implant failure. In contrast to nonbruxers, prostheses in bruxers had a higher failure rate. It suggests that bruxism is a contributing factor of causing the occurrence of dental implant technical/biological complications and plays a role in dental implant failure. © 2015 Wiley Periodicals, Inc.

  9. Comparison of marginal bone loss between internal- and external-connection dental implants in posterior areas without periodontal or peri-implant disease.

    Science.gov (United States)

    Kim, Dae-Hyun; Kim, Hyun Ju; Kim, Sungtae; Koo, Ki-Tae; Kim, Tae-Il; Seol, Yang-Jo; Lee, Yong-Moo; Ku, Young; Rhyu, In-Chul

    2018-04-01

    The purpose of this retrospective study with 4-12 years of follow-up was to compare the marginal bone loss (MBL) between external-connection (EC) and internal-connection (IC) dental implants in posterior areas without periodontal or peri-implant disease on the adjacent teeth or implants. Additional factors influencing MBL were also evaluated. This retrospective study was performed using dental records and radiographic data obtained from patients who had undergone dental implant treatment in the posterior area from March 2006 to March 2007. All the implants that were included had follow-up periods of more than 4 years after loading and satisfied the implant success criteria, without any peri-implant or periodontal disease on the adjacent implants or teeth. They were divided into 2 groups: EC and IC. Subgroup comparisons were conducted according to splinting and the use of cement in the restorations. A statistical analysis was performed using the Mann-Whitney U test for comparisons between 2 groups and the Kruskal-Wallis test for comparisons among more than 2 groups. A total of 355 implants in 170 patients (206 EC and 149 IC) fulfilled the inclusion criteria and were analyzed in this study. The mean MBL was 0.47 mm and 0.15 mm in the EC and IC implants, respectively, which was a statistically significant difference ( P <0.001). Comparisons according to splinting (MBL of single implants: 0.34 mm, MBL of splinted implants: 0.31 mm, P =0.676) and cement use (MBL of cemented implants: 0.27 mm, MBL of non-cemented implants: 0.35 mm, P =0.178) showed no statistically significant differences in MBL, regardless of the implant connection type. IC implants showed a more favorable bone response regarding MBL in posterior areas without peri-implantitis or periodontal disease.

  10. Simulation of peri-implant bone healing due to immediate loading in dental implant treatments.

    Science.gov (United States)

    Chou, Hsuan-Yu; Müftü, Sinan

    2013-03-15

    The goal of this work was to investigate the role of immediate loading on the peri-implant bone healing in dental implant treatments. A mechano-regulatory tissue differentiation model that takes into account the stimuli through the solid and the fluid components of the healing tissue, and the diffusion of pluripotent stem cells into the healing callus was used. A two-dimensional axisymmetric model consisting of a dental implant, the healing callus tissue and the host bone tissue was constructed for the finite element analysis. Poroelastic material properties were assigned to the healing callus and the bone tissue. The effects of micro-motion, healing callus size, and implant thread design on the length of the bone-to-implant contact (BIC) and the bone volume (BV) formed in the healing callus were investigated. In general, the analysis predicted formation of a continuous layer of soft tissue along the faces of the implant which are parallel to the loading direction. This was predicted to be correlated with the high levels of distortional strain transferred through the solid component of the stimulus. It was also predicted that the external threads on the implant, redistribute the interfacial load, thus help reduce the high distortional stimulus and also help the cells to differentiate to bone tissue. In addition, the region underneath the implant apex was predicted to experience high fluid stimulus that results in the development of soft tissue. The relationship between the variables considered in this study and the outcome measures, BV and BIC, was found to be highly nonlinear. A three-way analysis of variance (ANOVA) of the results was conducted and it showed that micro-motion presents the largest hindrance to bone formation during healing. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Long-Term Fatigue and Its Probability of Failure Applied to Dental Implants

    Directory of Open Access Journals (Sweden)

    María Prados-Privado

    2016-01-01

    Full Text Available It is well known that dental implants have a high success rate but even so, there are a lot of factors that can cause dental implants failure. Fatigue is very sensitive to many variables involved in this phenomenon. This paper takes a close look at fatigue analysis and explains a new method to study fatigue from a probabilistic point of view, based on a cumulative damage model and probabilistic finite elements, with the goal of obtaining the expected life and the probability of failure. Two different dental implants were analysed. The model simulated a load of 178 N applied with an angle of 0°, 15°, and 20° and a force of 489 N with the same angles. Von Mises stress distribution was evaluated and once the methodology proposed here was used, the statistic of the fatigue life and the probability cumulative function were obtained. This function allows us to relate each cycle life with its probability of failure. Cylindrical implant has a worst behaviour under the same loading force compared to the conical implant analysed here. Methodology employed in the present study provides very accuracy results because all possible uncertainties have been taken in mind from the beginning.

  12. Small-diameter dental implants: An adjunct for retention, stability, and comfort for the edentulous patient

    Directory of Open Access Journals (Sweden)

    Antonio Scarano

    2012-10-01

    Full Text Available Aim: Studies have shown that mandibular implant overdentures significantly increase satisfaction and quality of life of edentulous elders. Improved chewing ability appears to have a positive impact on nutritional state. Materials and methods: Forty edentulous subjects received four permucosal mini-implants for overdentures in the interforamina region of the mandible. Almost all participants were still satisfied with their overdentures. Participant satisfaction concerning retention and stability of the mandibular overdenture was assessed. A micro invasive technique was adopted, without open flap and performed in one chirurgical step; this technique can be used also in the so-called “highrisk” patients (anticoagulant terapy, diabetes, etc. Results and conclusion: Results and conclusion The results suggest that a mandibular overdenture retained by 4 mini-implants may be the best treatment strategy for edentulous people with atrophic ridges. The use of mini-implants is in many cases a good clinical alternative to the use of larger diameter implants, in that they enable to reduce surgical time, bleeding, postoperative discomfort and healing time.

  13. Correlation Between Resonance Frequency Analysis and Bone Quality Assessments at Dental Implant Recipient Sites.

    Science.gov (United States)

    Fu, Min-Wen; Fu, Earl; Lin, Fu-Gong; Chang, Wei-Jeng; Hsieh, Yao-Dung; Shen, E-Chin

    To evaluate whether primary implant stability could be used to predict bone quality, the association between the implant stability quotient (ISQ) value and the bone type at the implant site was evaluated. Ninety-five implant sites in 50 patients were included. Bone type (categorized by Lekholm and Zarb) at the implant site was initially assessed using presurgical dental radiography. During the preparation of the implant site, a bone core specimen was carefully obtained. The bone type was assessed by tactile sensation during the drilling operation, according to the Misch criteria. The primary stability of the inserted implant was evaluated by resonance frequency analysis (RFA). The ISQ value was recorded. The bone core specimen was then examined by stereomicroscopy or microcomputed tomography (micro-CT), and the bone type was determined by the surface characteristics of the specimen, based on Lekholm and Zarb classification. Agreement between the bone quality assessed by the four methods (ie, presurgical radiography, tactile sensation, stereomicroscopy, and micro-CT) was tested by Cohen's kappa statistics, whereas the association between the ISQ value and the bone type was evaluated by the generalized linear regression model. The mean ISQ score was 72.6, and the score was significantly influenced by the maxillary or mandibular arch (P = .001). The bone type at the implant sites varied according to the assessment method. However, a significant influence of the arch was repeatedly noted when using radiography or tactile sensation. Among the four bone-quality assessment methods, a weak agreement existed only between stereomicroscopy and micro-CT, especially in the maxilla (κ = 0.469). A negative association between the ISQ value and the bone type assessed by stereomicroscopy or by micro-CT was significant in the maxilla, but not in the mandible, after adjustments for sex, age, and right/left side (P = .013 and P = .027 for stereomicroscopy and micro-CT, respectively

  14. Placement of fin type dental implant in three different surgical situations of alveolar bone

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2007-03-01

    Full Text Available Three different dental implant placements according to surgical implant bed situations were observed in its bone integration 3 months after dental implant insertion. This observation was done on implant system which has plateau or fin system. Elf implants were placed in the upper jaw in two patients. In case one, two implants were inserted immediately after tooth extraction, and the other six implants were placed in the alveolar crest regions in delayed implantation or in which the teeth had been extracted over 6 months of period. In case two, three implants were inserted in the post trauma region in the anterior maxilla, which the labial plate had been lost and reconstructed with bone grafting procedure using a mixture of alloplastic and autogenous bones. The alveolar reconstruction was needed to be performed due to only thin alveolar crest width was left intact. All of those implants observed showed in good integration.

  15. Accuracy of mechanical torque-limiting devices for dental implants.

    Science.gov (United States)

    L'Homme-Langlois, Emilie; Yilmaz, Burak; Chien, Hua-Hong; McGlumphy, Edwin

    2015-10-01

    A common complication in implant dentistry is unintentional implant screw loosening. The critical factor in the prevention of screw loosening is the delivery of the appropriate target torque value. Mechanical torque-limiting devices (MTLDs) are the most frequently recommended devices by the implant manufacturers to deliver the target torque value to the screw. Two types of MTLDs are available: friction-style and spring-style. Limited information is available regarding the influence of device type on the accuracy of MTLDs. The purpose of this study was to determine and compare the accuracy of spring-style and friction-style MTLDs. Five MTLDs from 6 different dental implant manufacturers (Astra Tech/Dentsply, Zimmer Dental, Biohorizons, Biomet 3i, Straumann [ITI], and Nobel Biocare) (n=5 per manufacturer) were selected to determine their accuracy in delivering target torque values preset by their manufacturers. All torque-limiting devices were new and there were 3 manufacturers for the friction-style and 3 manufacturers for the spring-style. The procedure of target torque measurement was performed 10 times for each device and a digital torque gauge (Chatillon Model DFS2-R-ND; Ametek) was used to record the measurements. Statistical analysis used nonparametric tests to determine the accuracy of the MTLDs in delivering target torque values and Bonferroni post hoc tests were used to assess pairwise comparisons. Median absolute difference between delivered torque values and target torque values of friction-style and spring-style MTLDs were not significantly different (P>.05). Accuracy of Astra Tech and Zimmer Dental friction-style torque-limiting devices were significantly different than Biohorizons torque-limiting devices (Ptorque value. Astra Tech and Zimmer Dental friction-style torque-limiting devices were significantly more accurate than Biohorizons (C) torque-limiting devices (Ptorque-limiting devices fell within ±10% of the target torque value preset by the

  16. Physico-Chemical and Biochemical Characteristics of Mixed Saliva in Patients at Various Time After Dental Implantation

    Directory of Open Access Journals (Sweden)

    Zekiy A.O.

    2015-12-01

    Full Text Available he study deals with comparison of physico-chemical (pH, buffer capacity, viscosity and biochemical (concentration of albumin, calcium, phosphate, the activity of aamylase and alkaline phosphatase variables in the mixed saliva (oral fluid, OF in persons with dental implants depending on its number (1-2 or 3 and more and time after installation (2-4 and 5-11 months, and those with satisfactory state of oral health and without implants. The pH value in OF was almost similar in patients of group comparison and at different times after implantation and at different number of implants. The OF buffer capacity in different periods after the installation of single implants varied, been typical for the comparison group. A 2.4-fold decrease of buffer capacity was character at 2-4 months after installation of three or more implants, later this decline has not recovered fully. The installation of a single implant was not accompanied by changes in the OF viscosity, while multiple dental implant installation let to increase of viscosity 2.1 times less than in the comparison group at 2-4 months terms. The alterations of some biochemical properties of OF after dental implantation were shown to depend on the number and timing since the load on the installed constructions. Thus, more significant changes in oral fluid are to reduce the buffer capacity and viscosity of oral fluid, the concentration of calcium ions and the activity of a-amylase, they may be stored at the time of 5-11 months after implantation. These changes are associated with possible functional properties of oral fluid, which may affect the adaptation of dental system to new functional conditions connected to dental implant installation.

  17. The Failure Envelope Concept Applied To The Bone-Dental Implant System.

    Science.gov (United States)

    Korabi, R; Shemtov-Yona, K; Dorogoy, A; Rittel, D

    2017-05-17

    Dental implants interact with the jawbone through their common interface. While the implant is an inert structure, the jawbone is a living one that reacts to mechanical stimuli. Setting aside mechanical failure considerations of the implant, the bone is the main component to be addressed. With most failure criteria being expressed in terms of stress or strain values, their fulfillment can mean structural flow or fracture. However, in addition to those effects, the bony structure is likely to react biologically to the applied loads by dissolution or remodeling, so that additional (strain-based) criteria must be taken into account. While the literature abounds in studies of particular loading configurations, e.g. angle and value of the applied load to the implant, a general study of the admissible implant loads is still missing. This paper introduces the concept of failure envelopes for the dental implant-jawbone system, thereby defining admissible combinations of vertical and lateral loads for various failure criteria of the jawbone. Those envelopes are compared in terms of conservatism, thereby providing a systematic comparison of the various failure criteria and their determination of the admissible loads.

  18. 10-year survival rate and the incidence of peri-implant disease of 374 titanium dental implants with a SLA surface: a prospective cohort study in 177 fully and partially edentulous patients.

    Science.gov (United States)

    van Velzen, Frank J J; Ofec, Ronen; Schulten, Engelbert A J M; Ten Bruggenkate, Christiaan M

    2015-10-01

    This prospective cohort study evaluates the 10-year survival and incidence of peri-implant disease at implant and patient level of sandblasted, large grid, and acid-etched titanium dental implants (Straumann, soft tissue level, SLA surface) in fully and partially edentulous patients. Patients who had dental implant surgery in the period between November 1997 and June 2001, with a follow-up of at least 10 years, were investigated for clinical and radiological examination. Among the 506 inserted dental implants in 250 patients, 10-year data regarding the outcome of implants were available for 374 dental implants in 177 patients. In the current study, peri-implantitis was defined as advanced bone loss (≧1.5 mm. postloading) in combination with bleeding on probing. At 10-year follow-up, only one implant was lost (0.3%) 2 months after implant surgery due to insufficient osseointegration. The average bone loss at 10 year postloading was 0.52 mm. Advanced bone loss at 10-year follow-up was present in 35 dental implants (9.8%). Seven percent of the observed dental implants showed bleeding on probing in combination with advanced bone loss and 4.2% when setting the threshold for advanced bone loss at 2.0 mm. Advanced bone loss without bleeding on probing was present in 2.8% of all implants. In this prospective study, the 10-year survival rate at implant and patient level was 99.7% and 99.4%, respectively. Peri-implantitis was present in 7% of the observed dental implants according to the above-mentioned definition of peri-implantitis. This study shows that SLA implants offer predictable long-term results as support in the treatment of fully and partially edentulous patients. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. A study on occlusal stability in shortened dental arches.

    Science.gov (United States)

    Sarita, Paulo T N; Kreulen, Cees M; Witter, Dick J; van't Hof, Martin; Creugers, Nico H J

    2003-01-01

    The aim of this study was to verify the hypothesis that shortened dental arches constitute a risk to occlusal stability. Using cluster samples, 725 subjects with shortened dental arches comprising intact anterior regions and zero to eight occluding pairs of posterior teeth and 125 subjects with complete dental arches were selected. Subjects with shortened dental arches were classified into eight categories according to arch length and symmetry. Parameters for occlusal stability were interdental spacing, occlusal tooth wear, occlusal contact of incisors in intercuspal position, and vertical and horizontal overlap. Additionally, tooth mobility and overeruption of unopposed teeth were assessed. Influence of independent variables (dental arch category, age, gender, and residence) on the parameters for occlusal stability was assessed by one-way ANOVA and Tukey's multiple range tests. Extreme shortened dental arches (zero to two pairs of occluding premolars) had significantly more interdental spacing, occlusal contact of incisors, and vertical overlap compared to complete dental arches. Occlusal wear and prevalence of mobile teeth were highest in these categories. The category with three to four occluding premolars had significantly more interdental spacing and, for the older age group, more anterior teeth in occlusal contact compared to complete dental arches. Age was consistently associated with increased changes in occlusal integrity. Signs of increased risk to occlusal stability seemed to occur in extreme shortened dental arches, whereas no such evidence was found for intermediate categories of shortened dental arches.

  20. Electrochemical removal of biofilms from titanium dental implant surfaces.

    Science.gov (United States)

    Schneider, Sebastian; Rudolph, Michael; Bause, Vanessa; Terfort, Andreas

    2018-06-01

    The infection of dental implants may cause severe inflammation of tissue and even bone degradation if not treated. For titanium implants, a new, minimally invasive approach is the electrochemical removal of the biofilms including the disinfection of the metal surface. In this project, several parameters, such as electrode potentials and electrolyte compositions, were varied to understand the underlying mechanisms. Optimal electrolytes contained iodide as well as lactic acid. Electrochemical experiments, such as cyclic voltammetry or measurements of open circuit potentials, were performed in different cell set-ups to distinguish between different possible reactions. At the applied potentials of E species are formed at the anode, such as triiodide and hydrogen peroxide. Ex situ tests with model biofilms of E. coli clearly demonstrated the effectiveness of the respective anolytes in killing the bacteria, as determined by the LIVE/DEAD™ assay. Using optimized electrolysis parameters of 30 s at 7.0 V and 300 mA, a 14-day old wildtype biofilm could be completely removed from dental implants in vitro. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Antibiotic use at dental implant placement.

    Science.gov (United States)

    Veitz-Keenan, Analia; Keenan, James R

    2015-06-01

    Cochrane Oral Health Groups Trial Register, Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE via OVID and EMBASE via OVID. Databases were searched with no language or date restrictions. Two authors independently reviewed the titles and the abstracts for inclusion. Disagreements were resolved by discussion. If needed, a third author was consulted. Included were randomised clinical trials with a follow-up of at least three months which evaluated the use of prophylactic antibiotic compared to no antibiotic or a placebo and examined different antibiotics of different doses and durations in patients undergoing dental implant placement. The outcomes were implant failure (considered as implant mobility, removal of implant due to bone loss or infection) and prosthesis failure (prosthesis could not be placed). Standard Cochrane methodology procedures were followed. Risk of bias was completed independently and in duplicate by two review authors. Results were expressed as risk ratios (RRs) using a random-effects model for dichotomous outcomes with 95% confidence intervals (CI). The statistical unit was the participant and not the prosthesis or implant. Heterogeneity including both clinical and methodological factors was investigated. Six randomised clinical trials with 1162 participants were identified for the review. Three trials compared 2 g of preoperative amoxicillin versus placebo (927 participants). One trial compared 3 g of preoperative amoxicillin versus placebo (55 participants). Another trial compared 1 g of preoperative amoxicillin plus 500 mg four times a day for two days versus no antibiotic (80 participants). An additional trial compared four groups: (1) 2 g of preoperative amoxicillin; (2) 2 g of preoperative amoxicillin plus 1 g twice a day for seven days; (3) 1 g of postoperative amoxicillin twice a day for seven days and (4) no antibiotics (100 participants). The overall body of the evidence was considered moderate.The meta-analysis of the

  2. Time course of surface characteristics of alkali- and heat-treated titanium dental implants during vacuum storage.

    Science.gov (United States)

    Kamo, Michimasa; Kyomoto, Masayuki; Miyaji, Fumiaki

    2017-08-01

    Current efforts to shorten the healing times of life-long dental implants and prevent their fouling by organic impurities have focused on using surface-modification treatments and alternative packaging, respectively. In this study, we investigated the time course of the surface characteristics, including the wettability, a protein-adsorption and apatite-formation abilities, of alkali- and heat-treated (AH-treated) Ti samples during storage in vacuum over a period of 52 weeks. The AH treatment resulted in the formation of a nanometer-scale needle-like rougher surface of the Ti samples. Although the water contact angle of the AH-treated Ti sample increased slightly, it remained as low as approximately 10° even after storage in vacuum for 52 weeks. There was no significant difference in the protein-adsorption and apatite-formation abilities of the AH-treated Ti sample before and after storage. Further, the AH-treated Ti sample exhibited greater protein-adsorption and apatite-formation abilities compared with the untreated one; regardless of the samples stored in vacuum or not. Apatite formed only on the AH-treated Ti surface. Therefore, subjecting Ti dental implants to the AH treatment and storing them in vacuum should help prevent their surfaces from getting contaminated. Further, it is expected that AH-treated Ti dental implants controllably aged during a shelf storage will exhibit high stability and bone-bonding bioactivity. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1453-1460, 2017. © 2016 Wiley Periodicals, Inc.

  3. Advances in bone augmentation to enable dental implant placement: Consensus Report of the Sixth European Workshop on Periodontology.

    Science.gov (United States)

    Tonetti, Maurizio S; Hämmerle, Christoph H F

    2008-09-01

    Bone augmentation procedures to enable dental implant placement are frequently performed in practice. In this session the European Workshop on Periodontology discussed the evidence in support of the procedures and examined both adverse events and implant performance in the augmented bone. While the available evidence improved both in quantity and quality since previous workshops the conclusions that could be drawn were limited by elements of design and/or reporting that are amenable to improvement. With regards to lateral bone augmentation, a sizable body of evidence supports its use to enable dental implant placement. The group recognized the potential for vertical ridge augmentation procedures to allow implant placement in clinical practice but questioned the applicability of these data to a wider array of operators and clinical settings. With regards to sinus floor augmentation, perforation of the sinus membrane, graft infection and graft loss resulting in inability of implant placement were the major reported adverse events. In cases with dental implants placed in pristine sites. The consensus emphasized the research need to answer questions on: (i) long-term performance of dental implants placed in augmented bone; (ii) the clinical performance of dental implants placed in augmented or pristine sites; and (iii) the clinical benefits of bone augmentation with respect to alternative treatments.

  4. Temperature evaluation of dental implant surface irradiated with high-power diode laser.

    Science.gov (United States)

    Rios, F G; Viana, E R; Ribeiro, G M; González, J C; Abelenda, A; Peruzzo, D C

    2016-09-01

    The prevalence of peri-implantitis and the absence of a standard approach for decontamination of the dental implant surface have led to searches for effective therapies. Since the source of diode lasers is portable, has reduced cost, and does not cause damage to the titanium surface of the implant, high-power diode lasers have been used for this purpose. The effect of laser irradiation on the implants is the elevation of the temperature surface. If this elevation exceeds 47 °C, the bone tissue is irreversibly damaged, so for a safety therapy, the laser parameters should be controlled. In this study, a diode laser of GaAsAl was used to irradiate titanium dental implants, for powers 1.32 to 2.64 W (real) or 2.00 to 4.00 W (nominal), in continuous/pulsed mode DC/AC, with exposure time of 5/10 s, with/without air flow for cooling. The elevation of the temperature was monitored in real time in two positions: cervical and apical. The best results for decontamination using a 968-nm diode laser were obtained for a power of 1.65 and 1.98 W (real) for 10 s, in DC or AC mode, with an air flow of 2.5 l/min. In our perspective in this article, we determine a suggested approach for decontamination of the dental implant surface using a 968-nm diode laser.

  5. Is bruxism a risk factor for dental implants? A systematic review of the literature.

    Science.gov (United States)

    Manfredini, Daniele; Poggio, Carlo E; Lobbezoo, Frank

    2014-06-01

    To systematically review the literature on the role of bruxism as a risk factor for the different complications on dental implant-supported rehabilitations. A systematic search in the National Library of Medicine's Medline Database was performed to identify all peer-reviewed papers in the English literature assessing the role of bruxism, as diagnosed with any other diagnostic approach (i.e., clinical assessment, questionnaires, interviews, polysomnography, and electromyography), as a risk factor for biological (i.e., implant failure, implant mobility, and marginal bone loss) or mechanical (i.e., complications or failures of either prefabricated components or laboratory-fabricated suprastructures) complications on dental implant-supported rehabilitations. The selected articles were reviewed according to a structured summary of the articles in relation to four main issues, viz., "P" - patients/problem/population, "I" - intervention, "C" - comparison, and "O" - outcome. A total of 21 papers were included in the review and split into those assessing biological complications (n = 14) and those reporting mechanical complications (n = 7). In general, the specificity of the literature for bruxism diagnosis and for the study of the bruxism's effects on dental implants was low. From a biological viewpoint, bruxism was not related with implant failures in six papers, while results from the remaining eight studies did not allow drawing conclusions. As for mechanical complications, four of the seven studies yielded a positive relationship with bruxism. Bruxism is unlikely to be a risk factor for biological complications around dental implants, while there are some suggestions that it may be a risk factor for mechanical complications. © 2012 Wiley Periodicals, Inc.

  6. Maxillary and mandibular immediately loaded implant-supported interim complete fixed dental prostheses on immediately placed dental implants with a digital approach: A clinical report.

    Science.gov (United States)

    Lewis, Ryan C; Harris, Bryan T; Sarno, Robert; Morton, Dean; Llop, Daniel R; Lin, Wei-Shao

    2015-09-01

    This clinical report describes the treatment of maxillary and mandibular immediate implant placement and immediately loaded implant-supported interim complete fixed dental prostheses with a contemporary digital approach. The virtual diagnostic tooth arrangement eliminated the need for a customized radiographic template, and the diagnostic data collection required for computer-guided surgery (digital diagnostic impressions, digital photographs, and a cone beam-computed tomography [CBCT] scan) was completed in a single visit with improved workflow efficiency. Computer-aided design and computer-aided manufacturing (CAD/CAM)-fabricated surgical templates and interim prosthesis templates were made in a dental laboratory to facilitate computer-guided surgery and the immediate loading process. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  7. Implantes dentales en pacientes adultos postrauma dentoalveolar. Estudio descriptivo

    Directory of Open Access Journals (Sweden)

    Edgardo González

    2016-04-01

    Conclusiones: En este estudio se presenta un protocolo establecido y se establece la necesidad de un diagnóstico detallado para planificar la rehabilitación mediante implantes dentales posterior a un trauma con un equipo multidisciplinario.

  8. Immediate Placement of Dental Implants into Fresh Extraction Socket of Periapical Lesion with Bone Augmentation Using Growth Factors (PRGF) and Graft Bone (Bio-Oss)

    OpenAIRE

    Piuryk, V. P.; Kareem, Shujairi Ahmed

    2016-01-01

    Immediate implant placement and loading can be done in a compromised bone. Curettage, cleaning of the whole area up to good bone quality and primary stability are the main necessities for success. The effect of local application of scaffold-like preparation rich in growth factors (PRGF) on bone regeneration in artificial defects and the potential effect of humidifying titanium dental implants with liquid PRGF on their osseointegration were investigated. The PRGF formulations were obtained fro...

  9. Influence of bioactive material coating of Ti dental implant surfaces on early healing and osseointegration of bone

    International Nuclear Information System (INIS)

    Yeo, In-Sung; Min, Seung-Ki; An, Young-Bai

    2010-01-01

    The dental implant surface type is one of many factors that determine the long-term clinical success of implant restoration. The implant surface consists of bioinert titanium oxide, but recently coatings with bioactive calcium phosphate ceramics have often been used on Ti implant surfaces. Bio-active surfaces are known to significantly improve the healing time of the human bone around the inserted dental implant. In this study, we characterized two types of coated implant surfaces by scanning electron microscopy, energy dispersive spectrometry, and surface roughness testing. The effect of surface modification on early bone healing was then tested by using the rabbit tibia model to measure bone-to-implant contact ratios and removal torque values. These modified surfaces showed different characteristics in terms of surface topography, chemical composition, and surface roughness. However, no significant differences were found in the bone-to-implant contact and the resistance to removal torque between these surfaces. Both the coated implants may induce similar favorable early bone responses in terms of the early functioning and healing of dental implants even though they differed in their surface characteristics.

  10. Implant angulation: 2-year retrospective analysis on the influence of dental implant angle insertion on marginal bone resorption in maxillary and mandibular osseous onlay grafts.

    Science.gov (United States)

    Ramaglia, Luca; Toti, Paolo; Sbordone, Carolina; Guidetti, Franco; Martuscelli, Ranieri; Sbordone, Ludovico

    2015-05-01

    The purpose of this study was to determine the existence of correlations between marginal peri-implant linear bone loss and the angulation of implants in maxillary and mandibular augmented areas over the course of a 2-year survey. Dependent variables described the sample of the present retrospective chart review. By using three-dimensional radiographs, input variables, describing the implant angulation (buccal-lingual angle [φ] and mesial-distal angle [θ]) were measured; outcome variables described survival rate and marginal bone resorption (MBR) around dental implants in autogenous grafts (10 maxillae and 14 mandibles). Pairwise comparisons and linear correlation coefficient were computed. The peri-implant MBR in maxillary buccal and palatal areas appeared less intensive in the presence of an increased angulation of an implant towards the palatal side. Minor MBR was recorded around mandibular dental implants positioned at a right angle and slightly angulated towards the mesial. Resorption in buccal areas may be less intensive as the angulation of placed implants increases towards the palatal area in the maxilla, whereas for the mandible, a greater inclination towards the lingual area could be negative. In the mandibular group, when the implant was slightly angulated in the direction of the distal area, bone resorption seemed to be more marked in the buccal area. In the planning of dental implant placement in reconstructed alveolar bone with autograft, the extremely unfavourable resorption at the buccal aspect should be considered; this marginal bone loss seemed to be very sensitive to the angulation of the dental implant.

  11. The effect of mucosal cuff shrinkage around dental implants during healing abutment replacement.

    Science.gov (United States)

    Nissan, J; Zenziper, E; Rosner, O; Kolerman, R; Chaushu, L; Chaushu, G

    2015-10-01

    Soft tissue shrinkage during the course of restoring dental implants may result in biological and prosthodontic difficulties. This study was conducted to measure the continuous shrinkage of the mucosal cuff around dental implants following the removal of the healing abutment up to 60 s. Individuals treated with implant-supported fixed partial dentures were included. Implant data--location, type, length, diameter and healing abutments' dimensions--were recorded. Mucosal cuff shrinkage, following removal of the healing abutments, was measured in bucco-lingual direction at four time points--immediately after 20, 40 and 60 s. anova was used to for statistical analysis. Eighty-seven patients (49 women and 38 men) with a total of 311 implants were evaluated (120 maxilla; 191 mandible; 291 posterior segments; 20 anterior segments). Two-hundred and five (66%) implants displayed thick and 106 (34%) thin gingival biotype. Time was the sole statistically significant parameter affecting mucosal cuff shrinkage around dental implants (P < 0.001). From time 0 to 20, 40 and 60 s, the mean diameter changed from 4.1 to 4.07, 3.4 and 2.81 mm, respectively. The shrinkage was 1%, 17% and 31%, respectively. The gingival biotype had no statistically significant influence on mucosal cuff shrinkage (P = 0.672). Time required replacing a healing abutment with a prosthetic element should be minimised (up to 20/40 s), to avoid pain, discomfort and misfit. © 2015 John Wiley & Sons Ltd.

  12. Effect of Polyvinyl Siloxane Viscosity on Accuracy of Dental Implant Impressions.

    Science.gov (United States)

    Ghahremanloo, Ahmad; Seifi, Mahdieh; Ghanbarzade, Jalil; Abrisham, Seyyed Mohammad; Javan, Rashid Abdolah

    2017-01-01

    The aim of this study was to compare the accuracy of dental implant impressions obtained by a combination of different impression techniques and viscosities of polyvinyl siloxane (PVS). Four parallel fixtures were placed between mental foramina in a master model of lower dental arch. Three different viscosities (putty/light body, medium body/light body, and monophase: heavy body) and direct and indirect techniques (six groups) were used, and seven impressions were obtained from each group (n=42). To measure the accuracy of impressions, drift, horizontal, and vertical angles of the implants, as well as the hex rotation of the implants in casts were evaluated using a digitizer device (1μm accuracy), in comparison with master arch. Data were analyzed using five-factor two-way ANOVA and Tukey's post-hoc test. The accuracy of impressions was assessed and the results showed that direct technique was not significantly different from indirect technique (P>0.05). Also, there were no significant differences between the mentioned viscosities except for the horizontal angle (P=0.006). Viscosity of impression materials is of high significance for the accuracy of dental impressions.

  13. Surface analysis of titanium dental implants with different topographies

    Directory of Open Access Journals (Sweden)

    Silva M.H. Prado da

    2000-01-01

    Full Text Available Cylindrical dental implants made of commercially pure titanium were analysed in four different surface finishes: as-machined, Al2O3 blasted with Al2O3 particles, plasma-sprayed with titanium beads and electrolytically coated with hydroxyapatite. Scanning electron microscopy (SEM with Energy Dispersive X-ray Analysis (EDX revealed the topography of the surfaces and provided qualitative results of the chemical composition of the different implants. X-ray Photoelectron Spectroscopy (XPS was used to perform chemical analysis on the surface of the implants while Laser Scanning Confocal Microscopy (LSM produced topographic maps of the analysed surfaces. Optical Profilometry was used to quantitatively characterise the level of roughness of the surfaces. The implant that was plasma-sprayed and the hydroxyapatite coated implant showed the roughest surface, followed by the implant blasted with alumina and the as-machined implant. Some remnant contamination from the processes of blasting, coating and cleaning was detected by XPS.

  14. Impact of a "TED-Style" presentation on potential patients' willingness to accept dental implant therapy: a one-group, pre-test post-test study.

    Science.gov (United States)

    Ghanem, Henry; Afrashtehfar, Kelvin Ian; Abi-Nader, Samer; Tamimi, Faleh

    2015-12-01

    A survey was conducted to assess the impact of a TED-like educational session on participants' willingness to accept dental implant therapy. Volunteers interested in having information about dental implant therapies were recruited and asked to complete a two-part survey before and after an educational session. The initial survey elicited demographic information, self-perceived knowledge on dental implants and willingness to this kind of treatment. A "TED-style" presentation that provided information about dental implant treatments was conducted before asking the participants to complete a second set of questions assessing the impact of the session. The survey was completed by 104 individuals, 78.8% were women and the mean age was 66.5±10.8. Before the educational session, 76.0% of the participants refused dental implants mainly due to lack of knowledge. After the educational session, the rejection of dental implants decreased by almost four folds to 20.2%. This study proved that an educational intervention can significantly increase willingness to accept treatment with dental implants in a segment of the population who is interested in having information about dental implant therapy. Furthermore, educational interventions, such as TED-like talks, might be useful to increase popular awareness on dental implant therapy.

  15. Impact of a "TED-Style" presentation on potential patients' willingness to accept dental implant therapy: a one-group, pre-test post-test study

    Science.gov (United States)

    Ghanem, Henry; Abi-Nader, Samer

    2015-01-01

    PURPOSE A survey was conducted to assess the impact of a TED-like educational session on participants' willingness to accept dental implant therapy. MATERIALS AND METHODS Volunteers interested in having information about dental implant therapies were recruited and asked to complete a two-part survey before and after an educational session. The initial survey elicited demographic information, self-perceived knowledge on dental implants and willingness to this kind of treatment. A "TED-style" presentation that provided information about dental implant treatments was conducted before asking the participants to complete a second set of questions assessing the impact of the session. RESULTS The survey was completed by 104 individuals, 78.8% were women and the mean age was 66.5±10.8. Before the educational session, 76.0% of the participants refused dental implants mainly due to lack of knowledge. After the educational session, the rejection of dental implants decreased by almost four folds to 20.2%. CONCLUSION This study proved that an educational intervention can significantly increase willingness to accept treatment with dental implants in a segment of the population who is interested in having information about dental implant therapy. Furthermore, educational interventions, such as TED-like talks, might be useful to increase popular awareness on dental implant therapy. PMID:26816573

  16. Economic evaluation of single-tooth replacement: dental implant versus fixed partial denture.

    Science.gov (United States)

    Kim, Younhee; Park, Joo-Yeon; Park, Sun-Young; Oh, Sung-Hee; Jung, YeaJi; Kim, Ji-Min; Yoo, Soo-Yeon; Kim, Seong-Kyun

    2014-01-01

    This study assessed the cost-effectiveness from a societal perspective of a dental implant compared with a three-unit tooth-supported fixed partial denture (FPD) for the replacement of a single tooth in 2010. A decision tree was developed to estimate cost-effectiveness over a 10-year period. The survival rates of single-tooth implants and FPDs were extracted from a meta-analysis of single-arm studies. Medical costs included initial treatment costs, maintenance costs, and costs to treat complications. Patient surveys were used to obtain the costs of the initial single-tooth implant or FPD. Maintenance costs and costs to treat complications were based on surveys of seven clinical experts at dental clinics or hospitals. Transportation costs were calculated based on the number of visits for implant or FPD treatment. Patient time costs were estimated using the number of visits and time required, hourly wage, and employment rate. Future costs were discounted by 5% to convert to present values. The results of a 10-year period model showed that a single dental implant cost US $261 (clinic) to $342 (hospital) more than an FPD and had an average survival rate that was 10.4% higher. The incremental cost-effectiveness ratio was $2,514 in a clinic and $3,290 in a hospital for a prosthesis in situ for 10 years. The sensitivity analysis showed that initial treatment costs and survival rate influenced the cost-effectiveness. If the cost of an implant were reduced to 80% of the current cost, the implant would become the dominant intervention. Although the level of evidence for effectiveness is low, and some aspects of single-tooth implants or FPDs, such as satisfaction, were not considered, this study will help patients requiring single-tooth replacement to choose the best treatment option.

  17. Patient satisfaction relating to implant treatment by undergraduate and postgraduate dental students--a pilot study.

    LENUS (Irish Health Repository)

    Harrison, P

    2009-08-01

    Recordings of patient satisfaction with provision of dental implant treatment are scarce. This study aimed to evaluate satisfaction amongst patients attending for provision of implant treatment by training undergraduate and postgraduate students at Dublin Dental School and Hospital (DDSH). A questionnaire was formulated and distributed to 100 individuals randomly selected from records of patients who had received implant treatment via student clinics in the previous 5 years. The response rate was 68%. Results showed a high overall level of satisfaction with treatment received.

  18. The Prevalence of Dental Implants and Related Factors in Patients with Sjögren Syndrome: Results from a Cohort Study.

    Science.gov (United States)

    Albrecht, Katinka; Callhoff, Johanna; Westhoff, Gisela; Dietrich, Thomas; Dörner, Thomas; Zink, Angela

    2016-07-01

    To investigate prevalence and patient-reported outcomes of dental implants in patients with Sjögren syndrome (SS). A total of 205 female patients from an observational cohort study answered oral health questionnaires about periodontal signs and symptoms, dentures, dental implants, comorbidities, and therapies that may interfere with bone remodeling. Data were compared with the reports of 87 female healthy controls. The patients were older than the controls (58 ± 12 and 54 ± 14 yrs, respectively) and differed substantially in the prevalence of self-reported gingivitis (60% and 35%), self-reported periodontitis (19% and 8%), and in the numbers of remaining teeth (21 ± 7 and 24 ± 5). Patients more frequently had removable prostheses (36% compared with 23%) and dental implants (16% compared with 7%). The 32 patients with SS with dental implants had a mean number of 3.1 ± 2.0 implants. Notably, for patients with implants, their oldest existing implant survived for a mean period of 4.9 ± 5.4 years. A total of 5 of 104 (4.8%) implants in the patients and none of the 14 implants in the controls had to be removed. A total of 75% of the patients were highly satisfied with the implants and 97% would recommend them to other patients with SS. A substantial portion of patients with SS have dental complications and require subsequent implants. The majority were satisfied with the implants and would recommend them to other patients. The high implant survival rate may encourage patients, rheumatologists, and dentists to consider dental implants for the treatment of patients with SS.

  19. Two-stage dental implants inserted in a one-stage procedure : a prospective comparative clinical study

    NARCIS (Netherlands)

    Heijdenrijk, Kees

    2002-01-01

    The results of this study indicate that dental implants designed for a submerged implantation procedure can be used in a single-stage procedure and may be as predictable as one-stage implants. Although one-stage implant systems and two-stage.

  20. Influence of different implant materials on the primary stability of orthodontic mini-implants.

    Science.gov (United States)

    Pan, Chin-Yun; Chou, Szu-Ting; Tseng, Yu-Chuan; Yang, Yi-Hsin; Wu, Chao-Yi; Lan, Ting-Hsun; Liu, Pao-Hsin; Chang, Hong-Po

    2012-12-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft(3) trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates(®) device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05). Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success. Copyright © 2012. Published by Elsevier B.V.

  1. Influence of different implant materials on the primary stability of orthodontic mini-implants

    Directory of Open Access Journals (Sweden)

    Chin-Yun Pan

    2012-12-01

    Full Text Available This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm. The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft3 trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates® device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05. Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success.

  2. Effect of lubricant on the reliability of dental implant abutment screw joint: An in vitro laboratory and three-dimension finite element analysis.

    Science.gov (United States)

    Wu, Tingting; Fan, Hongyi; Ma, Ruiyang; Chen, Hongyu; Li, Zhi; Yu, Haiyang

    2017-06-01

    Biomechanical factors play a key role in the success of dental implants. Fracture and loosening of abutment screws are major issues. This study investigated the effect of lubricants on the stability of dental implant-abutment connection. As lubricants, graphite and vaseline were coated on the abutment screw surface, respectively, and a blank without lubricant served as the control. The total friction coefficient (μ tot ), clamping force, fatigue behavior and detorque of the joint combined with dynamic cyclic loading were measured under different lubricating conditions. Further, a three-dimensional finite element analysis was used to investigate stress distribution, in conjunction with experimental images. The results showed that the lubricant reduced μ tot , which in turn led to an increase in clamping force. Decrease in loading increased the fatigue life of the screw. However, use of lubricant at high load reduced the fatigue life. Ductile fracture at the first thread of the screw was the chief failure mode, which was due to maximum von Mises stress. Higher stress levels occurred in the lubricant groups. Lubricated screws resulted in lower detorque which made the joint easier to loosen. In conclusion, the lubricant cannot effectively improve the reliability of dental implant-abutment connection. Keeping the interfaces of implant-screw uncontaminated and strengthening the surface of the screw may be recommend for clinical operation and future design. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Atomic force microscopy analysis of different surface treatments of Ti dental implant surfaces

    International Nuclear Information System (INIS)

    Bathomarco, R.V.; Solorzano, G.; Elias, C.N.; Prioli, R.

    2004-01-01

    The surface of commercial unalloyed titanium, used in dental implants, was analyzed by atomic force microscopy. The morphology, roughness, and surface area of the samples, submitted to mechanically-induced erosion, chemical etching and a combination of both, were compared. The results show that surface treatments strongly influence the dental implant physical and chemical properties. An analysis of the length dependence of the implant surface roughness shows that, for scan sizes larger than 50 μm, the average surface roughness is independent of the scanning length and that the surface treatments lead to average surface roughness in the range of 0.37 up to 0.48 μm. It is shown that the implant surface energy is sensitive to the titanium surface area. As the area increases there is a decrease in the surface contact angle

  4. Atomic force microscopy analysis of different surface treatments of Ti dental implant surfaces

    Science.gov (United States)

    Bathomarco, Ti R. V.; Solorzano, G.; Elias, C. N.; Prioli, R.

    2004-06-01

    The surface of commercial unalloyed titanium, used in dental implants, was analyzed by atomic force microscopy. The morphology, roughness, and surface area of the samples, submitted to mechanically-induced erosion, chemical etching and a combination of both, were compared. The results show that surface treatments strongly influence the dental implant physical and chemical properties. An analysis of the length dependence of the implant surface roughness shows that, for scan sizes larger than 50 μm, the average surface roughness is independent of the scanning length and that the surface treatments lead to average surface roughness in the range of 0.37 up to 0.48 μm. It is shown that the implant surface energy is sensitive to the titanium surface area. As the area increases there is a decrease in the surface contact angle.

  5. Success of dental implants in vascularised fibular osteoseptocutaneous flaps used as onlay grafts after marginal mandibulectomy.

    Science.gov (United States)

    Chang, Y-M; Pan, Y-H; Shen, Y-F; Chen, J-K; ALDeek, N F; Wei, F-C

    2016-12-01

    We have evaluated the survival of dental implants placed in vascularised fibular flap onlay grafts placed over marginal mandibulectomies and the effects on marginal bone loss of different types of soft tissue around implants under functional loading. From 2001-2009 we studied a total of 11 patients (1 woman and10 men), three of whom had had ameloblastoma and eight who had had squamous cell carcinomas resected. A total of 38 dental implants were placed either at the time of transfer of the vascularised fibular ostoseptocutaneous flaps (nine patients with 30 implants) or secondarily (two patients with eight implants). Four patients were given palatal mucosal grafts to replace intraoral skin flaps around the dental implants (n=13), and the other seven had the skin flaps around the dental implants thinned (n=25) at the second stage of implantation of the osteointegrated teeth. All vascularised fibular osteoseptocutaneous flaps were successfully transferred, and all implants survived a mean (range) of 73 (33-113) months after occlusal functional loading. The mean (SD) marginal bone loss was 0.5 (0.3) mm on both mesial and distal sides in patients who had palatal mucosal grafts, but 1.8 (1.6) mm, and 1.7 (1.5) mm, respectively, on the mesial and distal sides in the patients who had had thinning of their skin flaps. This difference is significant (p=0.008) with less resorption of bone in the group who had palatal mucosal grafts. Palatal mucosa around the implants helps to reduce resorption of bone after functional loading of implants. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Scapular Free Vascularised Bone Flaps for Mandibular Reconstruction: Are Dental Implants Possible?

    Directory of Open Access Journals (Sweden)

    Martin Lanzer

    2015-09-01

    Full Text Available Objectives: Free fibula flap remains the flap of choice for reconstruction of mandibular defects. If free fibula flap is not possible, the subscapular system of flaps is a valid option. In this study, we evaluated the possibility of dental implant placement in patients receiving a scapular free flap for oromandibular reconstruction. Material and Methods: We retrospectively reviewed 10 patients undergoing mandible reconstruction with a subscapular system free-tissue (lateral border of the scapula transfer at the University Hospital Zürich between January 1, 2010 and January 1, 2013. Bone density in cortical and cancellous bone was measured in Hounsfield units (HU. Changes of bone density, height and width were analysed using IBM SPSS Statistics 22. Comparisons of bone dimensions as well as bone density were performed using a chi-square test. Results: Ten patients were included. Implantation was conducted in 50%. However, all patients could have received dental implants considering bone stock. Loss of bone height and width were significant (P < 0.001. There was a statistical significant increase in bone density in cortical (P < 0.001 and cancellous (P = 0.004 bone. Conclusions: Dental implants are possible after scapular free flap reconstruction of oromandibular defects. Bone height and width were reduced, while bone density increased with time.

  7. Preferred Source and Perceived Need of More Information about Dental Implants by the Undergraduate Dental Students of Nepal: All Nepal Survey

    Directory of Open Access Journals (Sweden)

    Arati Sharma

    2018-01-01

    Full Text Available Objectives. This study was conducted to know the preferred source and perceived need of more information about dental implants by the undergraduate students of Nepal and their association with academic levels and gender. Materials and Methods. It was conducted in all the dental colleges of Nepal from June 2016 to June 2017 after taking ethical clearance and approval from the research committee of BPKIHS. It included all those who were present at the time of survey. Data collection was done through a cross-sectional questionnaire survey during the academic schedule of the colleges, supervised and monitored by the investigators themselves. The collected data were coded and entered in Microsoft excel 2013, and statistical analysis was done by SPSS 20 version. Result. A majority of the respondents agreed that they were not provided with sufficient information about implant treatment procedures during their BDS program (65.3%, would like more to be provided in the curriculum (95.1%, and would like to get additional reliable information from dental consultants and specialists (40.7% and training on it from fellowship programs conducted by universities (39.2%. Significant association was seen between the responses and academic levels. Conclusion. Undergraduate dental students of Nepal want more information about dental implants through various means.

  8. Preferred Source and Perceived Need of More Information about Dental Implants by the Undergraduate Dental Students of Nepal: All Nepal Survey.

    Science.gov (United States)

    Sharma, Arati; Shrestha, Bidhan; Chaudhari, Bijay Kumar; Suwal, Pramita; Singh, Raj Kumar; Niraula, Surya Raj; Parajuli, Prakash Kumar

    2018-01-01

    This study was conducted to know the preferred source and perceived need of more information about dental implants by the undergraduate students of Nepal and their association with academic levels and gender. It was conducted in all the dental colleges of Nepal from June 2016 to June 2017 after taking ethical clearance and approval from the research committee of BPKIHS. It included all those who were present at the time of survey. Data collection was done through a cross-sectional questionnaire survey during the academic schedule of the colleges, supervised and monitored by the investigators themselves. The collected data were coded and entered in Microsoft excel 2013, and statistical analysis was done by SPSS 20 version. A majority of the respondents agreed that they were not provided with sufficient information about implant treatment procedures during their BDS program (65.3%), would like more to be provided in the curriculum (95.1%), and would like to get additional reliable information from dental consultants and specialists (40.7%) and training on it from fellowship programs conducted by universities (39.2%). Significant association was seen between the responses and academic levels. Undergraduate dental students of Nepal want more information about dental implants through various means.

  9. Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series.

    Science.gov (United States)

    Gay-Escoda, C; Pérez-Álvarez, D; Camps-Font, O; Figueiredo, R

    2016-05-01

    The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and surgical complications. Additionally, the patients were assessed for implant survival and success rates and for the prevalence of peri-implant diseases. A descriptive statistical analysis of the data was performed. Nine participants (57 implants) were included. The patients' median age was 42 years (IQR=13.5 years). The implant survival and success rates were 98.3% and 68.4%, respectively, with a mean follow-up of 77.5 months (SD=16.1 months). The patient-based prevalence of peri-implant mucositis and peri-implantitis were 22.2% and 44.4% respectively at the last appointment. Patients that attended regular periodontal maintenance visits had significantly less mean bone loss than non-compliant patients (1.3 mm and 3.9 mm respectively). Oral rehabilitation with dental implants in HIV-positive patients seems to provide satisfactory results. In order to reduce the considerably high prevalence of peri-implant diseases, strict maintenance programmes must be implemented.

  10. Comparison between tapered and cylindrical implants in the posterior regions of the mandible: A prospective, randomized, split-mouth clinical trial focusing on implant stability changes during early healing

    DEFF Research Database (Denmark)

    Waechter, Janine; Madruga, Marina de Mattos; Carmo Filho, Luiz Carlos

    2017-01-01

    ), the peri-implant inflammation (PI), the probing depth index (PDI), and the gingival bleeding index (GBI). Significant differences were investigated with t-tests for independent samples, chi-square tests or Fisher's exact test. Pearson's correlation test was used to investigate the relationship between...... = .0002), followed by a gradual increase beginning at 21 days (P = .0010) until the last follow-up time at 90 days (P = .0319). The cortical height was correlated with IT; while medullary bone dimensions were correlated with the PS as evidenced by the ISQ values. The insertion torque was significantly...... correlated with the PS only for the cylindrical dental implants. CONCLUSIONS: Tapered and cylindrical implants have similar biological behavior during the healing process. Bone site characteristics can influence insertion torque and implant stability....

  11. Progress and trends in patients' mindset on dental implants. I: level of information, sources of information and need for patient information.

    Science.gov (United States)

    Pommer, Bernhard; Zechner, Werner; Watzak, Georg; Ulm, Christian; Watzek, Georg; Tepper, Gabor

    2011-02-01

    Little is known about the level of information on implant dentistry in the public. A representative opinion poll on dental implants in the Austrian population was published in 2003 (Clinical Oral Implants Research 14:621-642). Seven years later, the poll was rerun to assess the up-to-date information level and evaluate recent progress and trends in patients' mindset on dental implants. One thousand adults--representative for the Austrian population--were presented with a total of 19 questionnaire items regarding the level and the sources of information about dental implants as well as the subjective and objective need for patient information. Compared with the survey of 2003, the subjective level of patient information about implant dentistry has significantly increased in the Austrian population. The patients' implant awareness rate was 79%. The objective level of general knowledge about dental implants was still all but satisfactory revealing unrealistic patient expectations. Three-quarters trusted their dentists for information about dental implants, while one-quarter turned to the media. The patients' wish for high-quality implant restorations was significantly higher than in 2003, yet the majority felt that only specialists should perform implant dentistry. This representative survey reveals that dentists are still the main source of patient information, but throws doubt on the quality of their public relations work. Dentists must improve communication strategies to provide their patients with comprehensible, legally tenable information on dental implants and bridge information gaps in the future. © 2010 John Wiley & Sons A/S.

  12. New Design for Rapid Prototyping of Digital Master Casts for Multiple Dental Implant Restorations.

    Directory of Open Access Journals (Sweden)

    Luis Romero

    Full Text Available This study proposes the replacement of all the physical devices used in the manufacturing of conventional prostheses through the use of digital tools, such as 3D scanners, CAD design software, 3D implants files, rapid prototyping machines or reverse engineering software, in order to develop laboratory work models from which to finish coatings for dental prostheses. Different types of dental prosthetic structures are used, which were adjusted by a non-rotatory threaded fixing system.From a digital process, the relative positions of dental implants, soft tissue and adjacent teeth of edentulous or partially edentulous patients has been captured, and a maser working model which accurately replicates data relating to the patients oral cavity has been through treatment of three-dimensional digital data.Compared with the conventional master cast, the results show a significant cost savings in attachments, as well as an increase in the quality of reproduction and accuracy of the master cast, with the consequent reduction in the number of patient consultation visits. The combination of software and hardware three-dimensional tools allows the optimization of the planning of dental implant-supported rehabilitations protocol, improving the predictability of clinical treatments and the production cost savings of master casts for restorations upon implants.

  13. New Design for Rapid Prototyping of Digital Master Casts for Multiple Dental Implant Restorations.

    Science.gov (United States)

    Romero, Luis; Jiménez, Mariano; Espinosa, María Del Mar; Domínguez, Manuel

    2015-01-01

    This study proposes the replacement of all the physical devices used in the manufacturing of conventional prostheses through the use of digital tools, such as 3D scanners, CAD design software, 3D implants files, rapid prototyping machines or reverse engineering software, in order to develop laboratory work models from which to finish coatings for dental prostheses. Different types of dental prosthetic structures are used, which were adjusted by a non-rotatory threaded fixing system. From a digital process, the relative positions of dental implants, soft tissue and adjacent teeth of edentulous or partially edentulous patients has been captured, and a maser working model which accurately replicates data relating to the patients oral cavity has been through treatment of three-dimensional digital data. Compared with the conventional master cast, the results show a significant cost savings in attachments, as well as an increase in the quality of reproduction and accuracy of the master cast, with the consequent reduction in the number of patient consultation visits. The combination of software and hardware three-dimensional tools allows the optimization of the planning of dental implant-supported rehabilitations protocol, improving the predictability of clinical treatments and the production cost savings of master casts for restorations upon implants.

  14. New Design for Rapid Prototyping of Digital Master Casts for Multiple Dental Implant Restorations

    Science.gov (United States)

    Romero, Luis; Jiménez, Mariano; Espinosa, María del Mar; Domínguez, Manuel

    2015-01-01

    Aim This study proposes the replacement of all the physical devices used in the manufacturing of conventional prostheses through the use of digital tools, such as 3D scanners, CAD design software, 3D implants files, rapid prototyping machines or reverse engineering software, in order to develop laboratory work models from which to finish coatings for dental prostheses. Different types of dental prosthetic structures are used, which were adjusted by a non-rotatory threaded fixing system. Method From a digital process, the relative positions of dental implants, soft tissue and adjacent teeth of edentulous or partially edentulous patients has been captured, and a maser working model which accurately replicates data relating to the patients oral cavity has been through treatment of three-dimensional digital data. Results Compared with the conventional master cast, the results show a significant cost savings in attachments, as well as an increase in the quality of reproduction and accuracy of the master cast, with the consequent reduction in the number of patient consultation visits. The combination of software and hardware three-dimensional tools allows the optimization of the planning of dental implant-supported rehabilitations protocol, improving the predictability of clinical treatments and the production cost savings of master casts for restorations upon implants. PMID:26696528

  15. Immediate placement of dental implants in the esthetic zone : a systematic review and pooled analysis

    NARCIS (Netherlands)

    Slagter, Kirsten W; den Hartog, Laurens; Bakker, Nicolaas A; Vissink, Arjan; Meijer, Henny J A; Raghoebar, Gerry M

    Background: Research interest on immediate placement of dental implants has shifted from implant survival toward optimal preservation of soft and hard tissues. The aim of this study is to systematically assess the condition of implant survival, peri-implant hard and soft tissue changes, esthetic

  16. Should edentulous patients be constrained to removable complete dentures? The use of dental implants to improve the quality of life for edentulous patients.

    Science.gov (United States)

    Turkyilmaz, Ilser; Company, Andrea M; McGlumphy, Edwin A

    2010-03-01

    Nowadays, there is some speculation among dental educators that the need for complete dentures will significantly decrease in the future and that training in their provision should be removed from the dental curriculum. To sensitise the reader to the functional shortcomings of complete denture therapy in the edentulous patient and present restorative options including implants to improve edentulous quality of life in these patients. Information retrieval followed a systematic approach using PubMed. English articles published from 1964 to 2008, in which the masticatory performance of patients with implant-supported dentures was assessed by objective methods and compared with performance with conventional dentures, were included. National epidemiological survey data suggested that the adult population in need of one or two complete dentures will increase from 35.4 million adults in 2000 to 37.9 million adults in 2020. Clinical studies have showed that the ratings of general satisfaction were significantly better in the patients treated with implant overdentures post-delivery compared with the complete denture users. In addition, the implant group gave significantly higher ratings on comfort, stability and ability to chew. Furthermore, patients who received mandibular implant overdentures had significantly fewer oral health-related quality of life problems than did the conventional group. Implant-supported dentures including either complete overdentures or a hybrid prosthesis significantly improve the quality of life for edentulous patients compared with conventional removable complete dentures. Therefore, the contemporary dental practitioner should consider other options as well as conventional removable complete dentures to restore edentulous patients.

  17. A technique to stabilize record bases for Gothic arch tracings in patients with implant-retained complete dentures.

    Science.gov (United States)

    Raigrodski, A J; Sadan, A; Carruth, P L

    1998-12-01

    Clinicians have long expressed concern about the accuracy of the Gothic arch tracing for recording centric relation in edentulous patients. With the use of dental implants to assist in retaining complete dentures, the problem of inaccurate recordings, made for patients without natural teeth, can be significantly reduced. This article presents a technique that uses healing abutments to stabilize the record bases so that an accurate Gothic arch tracing can be made.

  18. Investigational Clinical Trial of a Prototype Optoelectronic Computer-Aided Navigation Device for Dental Implant Surgery.

    Science.gov (United States)

    Jokstad, Asbjørn; Winnett, Brenton; Fava, Joseph; Powell, David; Somogyi-Ganss, Eszter

    New digital technologies enable real-time computer-aided (CA) three-dimensional (3D) guidance during dental implant surgery. The aim of this investigational clinical trial was to demonstrate the safety and effectiveness of a prototype optoelectronic CA-navigation device in comparison with the conventional approach for planning and effecting dental implant surgery. Study participants with up to four missing teeth were recruited from the pool of patients referred to the University of Toronto Graduate Prosthodontics clinic. The first 10 participants were allocated to either a conventional or a prototype device study arm in a randomized trial. The next 10 participants received implants using the prototype device. All study participants were restored with fixed dental prostheses after 3 (mandible) or 6 (maxilla) months healing, and monitored over 12 months. The primary outcome was the incidence of any surgical, biologic, or prosthetic adverse events or device-related complications. Secondary outcomes were the incidence of positioning of implants not considered suitable for straightforward prosthetic restoration (yes/no); the perception of the ease of use of the prototype device by the two oral surgeons, recorded by use of a Likert-type questionnaire; and the clinical performance of the implant and superstructure after 1 year in function. Positioning of the implants was appraised on periapical radiographs and clinical photographs by four independent blinded examiners. Peri-implant bone loss was measured on periapical radiographs by a blinded examiner. No adverse events occurred related to placing any implants. Four device-related complications led to a switch from using the prototype device to the conventional method. All implants placed by use of the prototype device were in a position considered suitable for straightforward prosthetic restoration (n = 21). The qualitative evaluation by the surgeons was generally positive, although ergonomic challenges were identified

  19. Evaluation of electron beam stabilization for ion implant processing

    Science.gov (United States)

    Buffat, Stephen J.; Kickel, Bee; Philipps, B.; Adams, J.; Ross, Matthew F.; Minter, Jason P.; Marlowe, Trey; Wong, Selmer S.

    1999-06-01

    With the integration of high energy ion implant processes into volume CMOS manufacturing, the need for thick resist stabilization to achieve a stable ion implant process is critical. With new photoresist characteristics, new implant end station characteristics arise. The resist outgassing needs to be addressed as well as the implant profile to ensure that the dosage is correct and the implant angle does not interfere with other underlying features. This study compares conventional deep-UV/thermal with electron beam stabilization. The electron beam system used in this study utilizes a flood electron source and is a non-thermal process. These stabilization techniques are applied to a MeV ion implant process in a CMOS production process flow.

  20. Dental implants in patients with oral mucosal diseases - a systematic review.

    Science.gov (United States)

    Reichart, P A; Schmidt-Westhausen, A M; Khongkhunthian, P; Strietzel, F P

    2016-05-01

    To reveal dental implants survival rates in patients with oral mucosal diseases: oral lichen planus (OLP), Sjögren's syndrome (SjS), epidermolysis bullosa (EB) and systemic sclerosis (SSc). A systematic literature search using PubMed/Medline and Embase databases, utilising MeSH and search term combinations identified publications on clinical use implant-prosthetic rehabilitation in patients with OLP, SjS, EB, SSc reporting on study design, number, gender and age of patients, follow-up period exceeding 12 months, implant survival rate, published in English between 1980 and May 2015. After a mean observation period (mOP) of 53·9 months (standard deviation [SD] ±18·3), 191 implants in 57 patients with OLP showed a survival rate (SR) of 95·3% (SD ±21·2). For 17 patients with SjS (121 implants, mOP 48·6 ± 28·7 months), 28 patients with EB (165 implants, mOP 38·3 ± 16·9 months) and five patients with SSc (38 implants, mOP 38·3 ± 16·9 months), the respective SR was 91·7 ± 5·97% (SjS), 98·5 ± 2·7% (EB) and 97·4 ± 4·8% (SSc). Heterogeneity of data structure and quality of reporting outcomes did not allow for further comparative data analysis. For implant-prosthetic rehabilitation of patients suffering from OLP, SjS, EB and SSc, no evidence-based treatment guidelines are presently available. However, no strict contraindication for the placement of implants seems to be justified in patients with OLP, SjS, EB nor SSc. Implant survival rates are comparable to those of patients without oral mucosal diseases. Treatment guidelines as for dental implantation in patients with healthy oral mucosa should be followed. © 2015 John Wiley & Sons Ltd.

  1. Failure analysis of fractured dental zirconia implants.

    Science.gov (United States)

    Gahlert, M; Burtscher, D; Grunert, I; Kniha, H; Steinhauser, E

    2012-03-01

    The purpose of the present study was the macroscopic and microscopic failure analysis of fractured zirconia dental implants. Thirteen fractured one-piece zirconia implants (Z-Look3) out of 170 inserted implants with an average in situ period of 36.75±5.34 months (range from 20 to 56 months, median 38 months) were prepared for macroscopic and microscopic (scanning electron microscopy [SEM]) failure analysis. These 170 implants were inserted in 79 patients. The patient histories were compared with fracture incidences to identify the reasons for the failure of the implants. Twelve of these fractured implants had a diameter of 3.25 mm and one implant had a diameter of 4 mm. All fractured implants were located in the anterior side of the maxilla and mandibula. The patient with the fracture of the 4 mm diameter implant was adversely affected by strong bruxism. By failure analysis (SEM), it could be demonstrated that in all cases, mechanical overloading caused the fracture of the implants. Inhomogeneities and internal defects of the ceramic material could be excluded, but notches and scratches due to sandblasting of the surface led to local stress concentrations that led to the mentioned mechanical overloading by bending loads. The present study identified a fracture rate of nearly 10% within a follow-up period of 36.75 months after prosthetic loading. Ninety-two per cent of the fractured implants were so-called diameter reduced implants (diameter 3.25 mm). These diameter reduced implants cannot be recommended for further clinical use. Improvement of the ceramic material and modification of the implant geometry has to be carried out to reduce the failure rate of small-sized ceramic implants. Nevertheless, due to the lack of appropriate laboratory testing, only clinical studies will demonstrate clearly whether and how far the failure rate can be reduced. © 2011 John Wiley & Sons A/S.

  2. Success and Survival Rates of Dental Implants Restored at an Undergraduate Dental Clinic: A 13-Year Retrospective Study with a Mean Follow-up of 5.8 Years.

    Science.gov (United States)

    Daneshvar, Shahrzad S; Matthews, Debora C; Michuad, Pierre-Luc; Ghiabi, Edmond

    2016-01-01

    The purpose of this study was to evaluate the clinical, radiographic, and patient-based outcomes of dental implants placed at an undergraduate student dental clinic. A retrospective study was performed to determine the success and survival rates of dental implants placed at the undergraduate dental clinic at Dalhousie University between January 1999 and January 2012. Only patients with a minimum of 1-year follow-up were included. Clinical and radiographic assessments determined implant success and survival rates. Questionnaires recorded patients' satisfaction with esthetics, comfort, and ease of hygiene. Of the 352 patients (n = 591 implants) who received implants over 13 years, 165 patients completed the clinical and radiographic examinations. By the end of the study period, demographic information and implant characteristics were collected for 111 (n = 217 implants; 47.5% in the maxilla, 52.6% in the mandible) of these patients. Of those assessed clinically, 36.4% were males and 63.6% females, with a mean age of 56.1 ± 14.15 years (range, 17 to 86 years) at the time of implant placement. The mean follow-up period was 5.8 years (range, 1 to 13 years). The overall implant success and survival rates were 88.0% and 97.2%, respectively. No observable bone loss was evident in 88.0% of the surviving implants. There were no implant fractures. Most patients (91.2%) were very satisfied with the implant restoration appearance, 88.0% were very comfortable with the implant, 92.6% were very satisfied with their ability to chew, and 84.8% reported easy hygiene maintenance at the implant sites. Implant success and survival in an undergraduate student clinic were comparable to those reported in the literature. It seems that inexperienced students were able to provide restorations that were very satisfying to the patients.

  3. Fracture analysis of randomized implant-supported fixed dental prostheses

    Science.gov (United States)

    Esquivel-Upshaw, Josephine F.; Mehler, Alex; Clark, Arthur E.; Neal, Dan; Anusavice, Kenneth J.

    2014-01-01

    Objective Fractures of posterior fixed dental all-ceramic prostheses can be caused by one or more factors including prosthesis design, flaw distribution, direction and magnitude of occlusal loading, and nature of supporting infrastructure (tooth root/implant), and presence of adjacent teeth. This clinical study of implant-supported, all-ceramic fixed dental prostheses, determined the effects of (1) presence of a tooth distal to the most distal retainer; (2) prosthesis loading either along the non-load bearing or load bearing areas; (3) presence of excursive contacts or maximum intercuspation contacts in the prosthesis; and (4) magnitude of bite force on the occurrence of veneer ceramic fracture. Methods 89 implant-supported FDPs were randomized as either a three-unit posterior metal-ceramic (Au-Pd-Ag alloy and InLine POM, Ivoclar, Vivadent) FDP or a ceramic-ceramic (ZirCAD and ZirPress, Ivoclar, Vivadent) FDP. Two implants (Osseospeed, Dentsply) and custom abutments (Atlantis, Dentsply) supported these FDPs, which were cemented with resin cement (RelyX Universal Cement). Baseline photographs were made with markings of teeth from maximum intercuspation (MI) and excursive function. Patients were recalled at 6 months and 1 to 3 years. Fractures were observed, their locations recorded, and images compared with baseline photographs of occlusal contacts. Conclusion No significant relationship exists between the occurrence of fracture and: (1) the magnitude of bite force; (2) a tooth distal to the most distal retainer; and (3) contacts in load-bearing or non-load-bearing areas. However, there was a significantly higher likelihood of fracture in areas with MI contacts only. Clinical Significance This clinical study demonstrates that there is a need to evaluate occlusion differently with implant-supported prostheses than with natural tooth supported prostheses because of the absence of a periodontal ligament. Implant supported prostheses should have minimal occlusion and

  4. Rehabilitation of Posterior Maxilla with Zygomatic and Dental Implant after Tumor Resection: A Case Report

    Directory of Open Access Journals (Sweden)

    Faysal Ugurlu

    2013-01-01

    Full Text Available Zygomatic implants have been used for dental rehabilitation in patients with insufficient bone in the posterior upper jaw, due to, for example, tumor resection, trauma, or atrophy. Zygomatic implants are an alternative to complex free or vascularized bone grafting and distraction osteogenesis. A 42-year-old male patient with a severe defect in the right posterior maxilla, starting from the first canine region, which had occurred after tumor resection 3 years earlier, was referred to our department. One zygomatic implant (Brenemark System, Nobel Biocare, Goteborg, Sweden to the zygoma and one dental implant to the canine region were placed. After a 5-month osseointegration period, a fixed denture was fabricated and adapted to the implants. Although the surgical and prosthetic procedures for zygoma implants are not easy, the final outcomes can be successful with appropriate planning.

  5. Preoperative CT analysis of the mandible and maxilla for permanent dental prosthetic implantation

    International Nuclear Information System (INIS)

    Rothman, S.L.G.; Rhodes, M.L.; Schwarz, M.; Chafetz, N.I.

    1987-01-01

    The Branemark technique for permanently implanting dental prostheses is becoming universally accepted. The surgeon requires detailed knowledge of the cross-sectional anatomy of the alveolar ridges and inferior alveolar nerve for safe placement of the titanium fixtures. Axial CT scans of the mandible and maxilla, with oblique and panoramic CT reformations, were obtained in more than 100 patients. This report describes the anatomic variations in the maxilla and mandible as they relate to dental implantation surgery. The authors demonstrate the utility of this technique in preoperative surgical planning and postoperative evaluation

  6. Effect of surface contamination on osseointegration of dental implants surrounded by circumferential bone defects.

    LENUS (Irish Health Repository)

    Mohamed, Seif

    2010-05-01

    This study was designed to evaluate the effect of surface contamination on osseointegration of dental implants surrounded by a circumferential bone defect and to compare osseointegration around Osseotite with that around Nanotite implants.

  7. Management of Broken Dental Implant Abutment in a Patient with Bruxism: A Rare Case Report and Review of Literature.

    Science.gov (United States)

    Al-Almaie, Saad

    2017-01-01

    This rare case report describes prosthodontic complications resulting from a dental implant was placed surgically more distally in the area of the missing mandibular first molar with a cantilever effect and a crest width of >12 mm in a 59-year-old patient who had a history of bruxism. Fracture of abutment is a common complication in implant was placed in area with high occlusal forces. Inability to remove the broken abutment may most often end up in discarding the implant. Adding one more dental implant mesially to the previously placed implant, improvisation of technique to remove the broken abutment without sacrificing the osseointegrated dental implant, fabrication with cemented custom-made abutment to replace the broken abutment for the first implant, and the use of the two implants to replace a single molar restoration proved reliable and logical treatment solutions to avoid these prosthodontic complications.

  8. Management of broken dental implant abutment in a patient with bruxism: A rare case report and review of literature

    Directory of Open Access Journals (Sweden)

    Saad Al-Almaie

    2017-01-01

    Full Text Available This rare case report describes prosthodontic complications resulting from a dental implant was placed surgically more distally in the area of the missing mandibular first molar with a cantilever effect and a crest width of >12 mm in a 59-year-old patient who had a history of bruxism. Fracture of abutment is a common complication in implant was placed in area with high occlusal forces. Inability to remove the broken abutment may most often end up in discarding the implant. Adding one more dental implant mesially to the previously placed implant, improvisation of technique to remove the broken abutment without sacrificing the osseointegrated dental implant, fabrication with cemented custom-made abutment to replace the broken abutment for the first implant, and the use of the two implants to replace a single molar restoration proved reliable and logical treatment solutions to avoid these prosthodontic complications.

  9. Peri-Implant Behavior of Sloped Shoulder Dental Implants Used for All-On-Four Protocols: An Histomorphometric Analysis in Dogs

    Directory of Open Access Journals (Sweden)

    Jose Luis Calvo Guirado

    2018-01-01

    Full Text Available The aim of this study was to evaluate the soft tissue thickness and marginal bone loss around dental implants with sloped micro-threaded shoulder (35° angle in comparing with conventional design, inserted 35° degrees angulated in post extraction sockets and immediate loaded with temporary prosthesis simulating the all-on-four protocol. Materials and Methods: Six fox hound dogs received forty-eight post extraction dental implants with the same diameter and length (Medentika, Germany, but with different neck configurations. Two group of implants were inserted 1mm subcrestal. Control group has a micro-threaded neck and the Test group has a sloped microthreaded neck. Immediate loading was applied using a constructed metallic structure. After three months, soft and hard tissue levels were assessed by histomorphometric analysis. Results: The mean soft tissue thickness (STT was 2.5 ± 0.2 mm for the Control group and 3.3 ± 0.3 mm for Test group (p = 0.036, meanwhile the mean marginal bone loss (MBL was 1.53 ± 0.34 mm for Control group and, 1.62 ± 0.22 mm for Test group (p > 0.05. Conclusions: Within the limitations of this experimental model in dogs, the findings showed that dental implants with microthreaded and microthreaded sloped necks installed in immediate post extraction sites with immediate load, presented a comparable perimplant tissue behavior.

  10. Facilitators and barriers influencing the readiness to receive dental implants in a geriatric institutionalised population-A randomized non-invasive interventional study.

    Science.gov (United States)

    Merz, Miriam A; Terheyden, Hendrik; Huber, Christian G; Seixas, Azizi A; Schoetzau, Andreas; Schneeberger, Andres R

    2017-09-01

    Although elderly people have many serious dental issues and are in need of prosthesis, few opt for dental implants. The aim of this study was to investigate barriers that prevent elderly people from receiving dental implants. Specifically, we examined (i) whether the message was delivered before or after the interview had an impact, and (ii) whether it did matter who delivered the message. Sixty-six residents from seven residential homes in the Canton of Grisons, Switzerland were included. The sample was randomized to a treatment group that received comprehensive education about dental implants before the interview and a control group that received education after completing the questionnaire. The sample consisted of 54 women (81.8%) and 12 males (18.2%) with an average age of 86.2 years. Education before the interview did not show any impact on the attitude towards dental implants. Main reasons for a negative attitude towards implants were old age and high costs. Participants who received information about implants from their relatives and their own dentist and not from the study dentist were significantly more willing to receive implants. Providing an adequate education about benefits and risks of receiving dental implants does not change the attitude towards dental implants. The source of information/messenger does influence attitudes towards implants. If the person delivering the education and information is a relative or a known medical person, the person's attitude is more likely to change as compared to people receiving the information from an unrelated person. © 2017 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.

  11. Influence of metallic dental implants and metal artefacts on dose calculation accuracy.

    Science.gov (United States)

    Maerz, Manuel; Koelbl, Oliver; Dobler, Barbara

    2015-03-01

    Metallic dental implants cause severe streaking artefacts in computed tomography (CT) data, which inhibit the correct representation of shape and density of the metal and the surrounding tissue. The aim of this study was to investigate the impact of dental implants on the accuracy of dose calculations in radiation therapy planning and the benefit of metal artefact reduction (MAR). A second aim was to determine the treatment technique which is less sensitive to the presence of metallic implants in terms of dose calculation accuracy. Phantoms consisting of homogeneous water equivalent material surrounding dental implants were designed. Artefact-containing CT data were corrected using the correct density information. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated on corrected and uncorrected CT data and compared to 2-dimensional dose measurements using GafChromic™ EBT2 films. For all plans the accuracy of dose calculations is significantly higher if performed on corrected CT data (p = 0.015). The agreement of calculated and measured dose distributions is significantly higher for VMAT than for IMRT plans for calculations on uncorrected CT data (p = 0.011) as well as on corrected CT data (p = 0.029). For IMRT and VMAT the application of metal artefact reduction significantly increases the agreement of dose calculations with film measurements. VMAT was found to provide the highest accuracy on corrected as well as on uncorrected CT data. VMAT is therefore preferable over IMRT for patients with metallic implants, if plan quality is comparable for the two techniques.

  12. Influence of metallic dental implants and metal artefacts on dose calculation accuracy

    International Nuclear Information System (INIS)

    Maerz, Manuel; Koelbl, Oliver; Dobler, Barbara

    2015-01-01

    Metallic dental implants cause severe streaking artefacts in computed tomography (CT) data, which inhibit the correct representation of shape and density of the metal and the surrounding tissue. The aim of this study was to investigate the impact of dental implants on the accuracy of dose calculations in radiation therapy planning and the benefit of metal artefact reduction (MAR). A second aim was to determine the treatment technique which is less sensitive to the presence of metallic implants in terms of dose calculation accuracy. Phantoms consisting of homogeneous water equivalent material surrounding dental implants were designed. Artefact-containing CT data were corrected using the correct density information. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated on corrected and uncorrected CT data and compared to 2-dimensional dose measurements using GafChromic trademark EBT2 films. For all plans the accuracy of dose calculations is significantly higher if performed on corrected CT data (p = 0.015). The agreement of calculated and measured dose distributions is significantly higher for VMAT than for IMRT plans for calculations on uncorrected CT data (p = 0.011) as well as on corrected CT data (p = 0.029). For IMRT and VMAT the application of metal artefact reduction significantly increases the agreement of dose calculations with film measurements. VMAT was found to provide the highest accuracy on corrected as well as on uncorrected CT data. VMAT is therefore preferable over IMRT for patients with metallic implants, if plan quality is comparable for the two techniques. (orig.) [de

  13. Micro-computerised tomography optimisation for the measurement of bone mineral density around titanium dental implants

    International Nuclear Information System (INIS)

    Park, C.; Swain, M.; Duncan, W.

    2010-01-01

    Titanium dental implants (screws) are commonly used to replace missing teeth by forming a biological union with bone ('osseointegration'). Micro-computerised tomography (μCT) may be useful for measuring bone mineral density around dental implants. Major issues arise because of various artefacts that occur with polychromatic X-rays associated bench type instruments that may compromise interpretation of the observations. In this study various approaches to minimise artefacts such as; beam hardening, filtering and edge effects are explored with a homogeneous polymeric material, Teflon, with and without an implant present. The implications of the limitations of using such polychromatic μCT systems to quantify bone mineral density adjacent to the implant are discussed. (author)

  14. Antibiotic prophylaxis for dental implant placement?

    Science.gov (United States)

    Keenan, James R; Veitz-Keenan, Analia

    2015-06-01

    Electronic searches without time or language restrictions were performed in PubMed, Web of Science and the Cochrane Oral Health Group trials Register. A vast manual search was done in many dental implant-related journals. Reference lists were scanned for possible additional studies. Ongoing clinical trials were also searched. Titles and abstracts of the reports identified were read independently by the three authors. Disagreements were resolved by discussion. Rejected studies were recorded with the reasons for exclusion. The inclusion criteria included clinical human studies, either randomised or not, comparing the implant failure/survival rates in any group of patients receiving antibiotic prophylaxis versus not receiving antibiotics prior to implant placement. Case reports and non-human studies were excluded. Implant failure was considered as complete loss of the implant. Data were extracted by the authors. Study risk of bias was assessed. Implant failure and post-operative infection were the outcomes measured, both dichotomous outcomes. Results were expressed using fixed or a random effect model depending on the heterogeneity calculated using an I(2) statistical test. The estimate of relative effect was expressed in risk ratio (RR) with 95% confidence interval. Number needed to treat (NNT) was calculated and sensitivity analysis was performed to detect differences among the studies considered to have high a risk of bias. Fourteen trials were included in the review and evaluated a total of 14,872 implants. Of the fourteen studies included in the review eight were randomised clinical trials, four were controlled clinical trials and two were retrospective studies. Seven studies had both patients and operators/outcome assessors blinded to the tested intervention. Nine studies had short follow-ups; six of them with a follow-up of four months, one of five months and two of six months.The antibiotic regimen was variable: seven studies did not use post-op antibiotics in

  15. Estimation of efficiency of new local rehabilitation method at the early post-operative period after dental implantation

    Directory of Open Access Journals (Sweden)

    A. V. Pasechnik

    2017-01-01

      Summary Despite of success of dental implantation, there are often complications at the early post-operative period of implant placing associated with wound damage and aseptic inflammation. Purpose of the work is studying clinical efficiency of combined local application of new mucosal gel “Apior” and magnetotherapy at the early post-operative period after dental implantation. Combined local application of the mucosal gel “Apior” and pulsating low-frequency electromagnetic field in the complex medical treatment of patients after conducting an operation of setting dental implants favourably affects the common state of patients and clinical symptoms of inflammation in the area of operating wound. As compared with patients who had traditional anti-inflammatory therapy, the patients treated with local application of apigel and magnetoterapy had decline of edema incidence, of gingival mucosa hyperemia, of discomfort in the area of conducted operation. There occurred more rapid improvement of inflammation painfulness, which correlated with the improvement of hygienic state of oral cavity and promoted to prevention of bacterial content of damaged mucous surfaces. Estimation of microvasculatory blood stream by the method of ultrasonic doppler flowmetry revealed more rapid normalization of volume and linear high systole speed of blood stream in the periimplant tissues in case of use of new complex local rehabilitation method, that testified to the less pronounced inflammation of oral mucosa after the operation. The authors came to conclusion that the local application of the offered method of medical treatment of early post-operative complications of dental implantation reduces terms of renewal of structural-functional integrity of oral mucosa, helps in preventing development of inflammatory complications and strengthening endosseus implant. The inclusion in the treatment management of a new combined method of application of mucosal gel “Apior” and

  16. Quasi-static strength and fractography analysis of two dental implants manufactured by direct metal laser sintering.

    Science.gov (United States)

    Gehrke, Sergio Alexandre; Pérez-Díaz, Leticia; Dedavid, Berenice Anina

    2018-01-30

    New manufacturing methods was developed to improve the tissues integration with the titanium alloy pieces. The present in vitro study was to assess the resistance and fracture mode after applied a quasi-static compressive force on the two dental implants manufactured by direct metal laser sintering. Twenty dental implants manufactured by direct metal laser sintering, using titanium alloy (Ti-6Al-4V) granules in two designs (n = 10 per group): Conventional dental implant (group Imp1) two-piece implant design, where the surgical implant and prosthetic abutment are two separate components and, the one-piece implant (group Imp2), where the surgical implant and prosthetic abutment are one integral piece. All samples were subjected to quasi-static loading at a 30° angle to the implant axis in a universal testing machine. The mean fracture strengths were 1269.2 ± 128.8 N for the group Imp1 and, 1259.5 ± 115.1 N for the group Imp2, without statistical differences (P = .8722). In both groups, the fracture surface does not present crack between the compact core and the superficial (less dense and porous) part of the implants. Based on the measured resistance data for the two implant models manufactured by direct metal laser sintering tested in the present study, we can suggest that they have adequate capacity to withstand the masticatory loads. © 2018 Wiley Periodicals, Inc.

  17. Conservative surgical and microsurgical techniques for the management of dental implants that impinge on the inferior alveolar nerve.

    Science.gov (United States)

    Gennaro, Paolo; Chisci, Glauco; Gabriele, Guido; Iannetti, Giorgio

    2014-07-01

    Loss of sensation in the lip after insertion of an implant is annoying. The aim of this paper was to describe two techniques for management of osseointegrated dental implants that impinge on the mandibular nerve, the purpose of which is to improve sensation without unscrewing the dental implant. Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Numb chin syndrome as a manifestation of possible breast cancer metastasis around dental implants.

    Science.gov (United States)

    Orhan, Kaan; Bayndr, Hakan; Aksoy, Seçil; Seker, Basak Kusakci; Berberoğlu, Atilla; Ozan, Oğuz

    2011-05-01

    Numb chin syndrome, sometimes called numb lip syndrome, is an uncommon but well-recognized symptom in medical oncology. It may be a metastatic neurologic manifestation of malignancy, often with no clinically visible pathologic finding. The authors report a numb chin syndrome as a manifestation possible breast cancer metastasis around dental implants in a 69-year-old woman. The patient was presented with complaint of numbness in the lower jaw. Medical anamnesis revealed a metastatic breast carcinoma (CA). Radiographic imaging with conventional panoramic radiography and cone beam computed tomographic examination, revealed a moth-eaten shape, radiolucent, and radiopaque mixed appearance around the dental implants that was related with possible metastasis of the breast cancer. Numb chin syndrome is almost unknown within the dental and oral and maxillofacial community, despite being well reported in the medical literature. General dentists, oral medicine specialists, and oral and maxillofacial surgeons must be aware of this condition to consider metastatic cancer in patients with unexplained facial hypoesthesia. Moreover, although the development of metastatic lesions around implants is an uncommon pathologic finding, the examination of peri-implant lesion should be performed carefully considering the entire pathologic situations.

  19. Direct Metal Laser Sintering Titanium Dental Implants: A Review of the Current Literature

    Science.gov (United States)

    Mangano, F.; Chambrone, L.; van Noort, R.; Miller, C.; Hatton, P.; Mangano, C.

    2014-01-01

    Statement of Problem. Direct metal laser sintering (DMLS) is a technology that allows fabrication of complex-shaped objects from powder-based materials, according to a three-dimensional (3D) computer model. With DMLS, it is possible to fabricate titanium dental implants with an inherently porous surface, a key property required of implantation devices. Objective. The aim of this review was to evaluate the evidence for the reliability of DMLS titanium dental implants and their clinical and histologic/histomorphometric outcomes, as well as their mechanical properties. Materials and Methods. Electronic database searches were performed. Inclusion criteria were clinical and radiographic studies, histologic/histomorphometric studies in humans and animals, mechanical evaluations, and in vitro cell culture studies on DMLS titanium implants. Meta-analysis could be performed only for randomized controlled trials (RCTs); to evaluate the methodological quality of observational human studies, the Newcastle-Ottawa scale (NOS) was used. Results. Twenty-seven studies were included in this review. No RCTs were found, and meta-analysis could not be performed. The outcomes of observational human studies were assessed using the NOS: these studies showed medium methodological quality. Conclusions. Several studies have demonstrated the potential for the use of DMLS titanium implants. However, further studies that demonstrate the benefits of DMLS implants over conventional implants are needed. PMID:25525434

  20. Direct metal laser sintering titanium dental implants: a review of the current literature.

    Science.gov (United States)

    Mangano, F; Chambrone, L; van Noort, R; Miller, C; Hatton, P; Mangano, C

    2014-01-01

    Statement of Problem. Direct metal laser sintering (DMLS) is a technology that allows fabrication of complex-shaped objects from powder-based materials, according to a three-dimensional (3D) computer model. With DMLS, it is possible to fabricate titanium dental implants with an inherently porous surface, a key property required of implantation devices. Objective. The aim of this review was to evaluate the evidence for the reliability of DMLS titanium dental implants and their clinical and histologic/histomorphometric outcomes, as well as their mechanical properties. Materials and Methods. Electronic database searches were performed. Inclusion criteria were clinical and radiographic studies, histologic/histomorphometric studies in humans and animals, mechanical evaluations, and in vitro cell culture studies on DMLS titanium implants. Meta-analysis could be performed only for randomized controlled trials (RCTs); to evaluate the methodological quality of observational human studies, the Newcastle-Ottawa scale (NOS) was used. Results. Twenty-seven studies were included in this review. No RCTs were found, and meta-analysis could not be performed. The outcomes of observational human studies were assessed using the NOS: these studies showed medium methodological quality. Conclusions. Several studies have demonstrated the potential for the use of DMLS titanium implants. However, further studies that demonstrate the benefits of DMLS implants over conventional implants are needed.

  1. Direct Metal Laser Sintering Titanium Dental Implants: A Review of the Current Literature

    Directory of Open Access Journals (Sweden)

    F. Mangano

    2014-01-01

    Full Text Available Statement of Problem. Direct metal laser sintering (DMLS is a technology that allows fabrication of complex-shaped objects from powder-based materials, according to a three-dimensional (3D computer model. With DMLS, it is possible to fabricate titanium dental implants with an inherently porous surface, a key property required of implantation devices. Objective. The aim of this review was to evaluate the evidence for the reliability of DMLS titanium dental implants and their clinical and histologic/histomorphometric outcomes, as well as their mechanical properties. Materials and Methods. Electronic database searches were performed. Inclusion criteria were clinical and radiographic studies, histologic/histomorphometric studies in humans and animals, mechanical evaluations, and in vitro cell culture studies on DMLS titanium implants. Meta-analysis could be performed only for randomized controlled trials (RCTs; to evaluate the methodological quality of observational human studies, the Newcastle-Ottawa scale (NOS was used. Results. Twenty-seven studies were included in this review. No RCTs were found, and meta-analysis could not be performed. The outcomes of observational human studies were assessed using the NOS: these studies showed medium methodological quality. Conclusions. Several studies have demonstrated the potential for the use of DMLS titanium implants. However, further studies that demonstrate the benefits of DMLS implants over conventional implants are needed.

  2. The team approach to managing dental implant complications: the periodontist's point of view.

    Science.gov (United States)

    Froum, Stuart J

    2013-10-01

    Implant-related complications are a fact of life among practitioners who place or restore implants. They occur for a variety of reasons with varying consequences. Those classified as minor complications are most easily corrected and may have little impact on the course of treatment, but severe complications can have serious consequence in expense, complexity, and ultimate success. Many severe complications may be irreversible, leaving the patient with less desirable esthetic options, or worse, permanent disability in terms of speech and function. While various members of the dental team may have different points of view, implant complications are a concern to all. Successful results require comprehensive care, collaborative treatment, and knowledge of dental implant complications. Therefore, it is in the best interest of the patient that all involved in treatment be aware of the different types of complications that can be experienced and learn how to work together as a team to achieve successful outcomes.

  3. Surgical stent for dental implant using cone beam CT images

    International Nuclear Information System (INIS)

    Choi, Hyung Soo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2010-01-01

    The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.

  4. Cost and lack of insurance coverage are prohibitive to having dental implants after resections for benign mandibular neoplasms.

    Science.gov (United States)

    Peacock, Zachary S; Ji, Yisi D

    2017-06-01

    To assess how often patients receive dental implants after mandibular resection for benign neoplasms and to determine barriers to completion of functional reconstruction. This was a retrospective cohort study of patients who underwent resection for benign mandibular neoplasms between 2005 and 2014. Demographic variables included age, sex, and race. Outcome variables include rates of implant placement, implant restoration, and reasons for not having implants. Fisher's exact test and odds ratios were calculated. In all, 52 subjects (age 47.1 ± 19.2 years) were included. Twenty (38.6%) received dental implants. Race was associated with the likelihood of receiving implants (P = .0302). African Americans (1/11, 9.1%) were least likely compared to all other racial groups to have implants (odds ratio = 0.1158; P = .035; 95% confidence interval 0.013-0.989). Caucasians (17/35, 48.6%) were 4.41 times more likely to receive implants compared to all other races (odds ratio = 4.41; 95% confidence interval 1.073-18.093; P = .038). Of the 20 patients who received implants, 10 went on to have dental prostheses. The most common reason for not having implants was cost (37.5% overall), cited by 50% of black and 16.7% of white patients. Patients do not typically go on to dental reconstruction after mandibular resection, with cost as a major barrier. African Americans were least likely to complete full reconstruction. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. The immediate placement of dental implants into extraction sites with periapical lesions: a retrospective chart review.

    Science.gov (United States)

    Bell, Christopher Lincoln; Diehl, David; Bell, Brian Michael; Bell, Robert E

    2011-06-01

    The purpose of this study was to evaluate the success of dental implants placed immediately into extraction sites in the presence of chronic periapical pathology. The charts of 655 patients who had implants immediately placed into fresh extraction sites were reviewed for the presence or absence of periapical radiolucencies. A total of 922 implants were included. Of the 922 implants, 285 were immediately placed into sockets that had chronic periapical infections. The remaining 637 implants, without signs of periapical pathology, were used as the control group. Success of the implants was defined as successful osseointegration, successful restoration, and absence of evidence of bone loss or peri-implantitis. Other variables such as age, gender, smoking, diabetes, bisphosphonate use, lucencies of adjacent teeth, and implant stability at the time of placement were also evaluated. Of the 922 implants, 285 were placed into sockets with periapical radiolucencies. The success rate of implants placed in the study group was 97.5%, whereas the success rate of the control group was 98.7%. The difference was not found to be statistically significant. The mean follow-up was 19.75 months, with a maximum of 93 months and a minimum of 3 months. A statistically higher failure rate was found for implants placed adjacent to retained teeth with periapical pathology. The placement of implants in sockets affected by chronic periapical pathology can be considered a safe and viable treatment option. There is a risk of implant failure when placing implants adjacent to teeth with periapical radiolucencies. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Interventions for replacing missing teeth: antibiotics at dental implant placement to prevent complications.

    Science.gov (United States)

    Esposito, Marco; Grusovin, Maria Gabriella; Worthington, Helen V

    2013-07-31

    Some dental implant failures may be due to bacterial contamination at implant insertion. Infections around biomaterials are difficult to treat, and almost all infected implants have to be removed. In general, antibiotic prophylaxis in surgery is only indicated for patients at risk of infectious endocarditis; with reduced host-response; when surgery is performed in infected sites; in cases of extensive and prolonged surgical interventions; and when large foreign materials are implanted. A variety of prophylactic systemic antibiotic regimens have been suggested to minimise infections after dental implant placement. More recent protocols recommended short-term prophylaxis, if antibiotics have to be used. Adverse events may occur with the administration of antibiotics, and can range from diarrhoea to life-threatening allergic reactions. Another major concern associated with the widespread use of antibiotics is the selection of antibiotic-resistant bacteria. The use of prophylactic antibiotics in implant dentistry is controversial. To assess the beneficial or harmful effects of systemic prophylactic antibiotics at dental implant placement versus no antibiotic or placebo administration and, if antibiotics are beneficial, to determine which type, dosage and duration is the most effective. We searched the Cochrane Oral Health Group's Trials Register (to 17 June 2013), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 5), MEDLINE via OVID (1946 to 17 June 2013) and EMBASE via OVID (1980 to 17 June 2013). There were no language or date restrictions placed on the searches of the electronic databases. Randomised controlled clinical trials (RCTs) with a follow-up of at least three months, that compared the administration of various prophylactic antibiotic regimens versus no antibiotics to people undergoing dental implant placement. Outcome measures included prosthesis failures, implant failures, postoperative infections and adverse

  7. Surface modification of yttria stabilized zirconia by ion implantation

    International Nuclear Information System (INIS)

    Scholten, D.

    1987-01-01

    The results of investigations of surface modification by ion implantation in zirconia are described. As dopant material, iron was investigated thoroughly. The depth distribution of implanted ions depends on implantation parameters and the dopant-matrix system. The investigations of thermal stability of some implanted iron profiles by RBS and AES are described. Special interest lies in the thermal stability under working conditions of the zirconia material (400-1000 0 C). Radiation damage introduced in the implanted layer was investigated using transmission electron microscopy on polycrystalline material and channeling experiments on a single crystal implanted with iron. 179 refs.; 87 figs.; 20 tabs

  8. AFM-investigation of differently treated Ti-surfaces with respect to their usability for dental implants

    Energy Technology Data Exchange (ETDEWEB)

    Wille, Sebastian; Adelung, Rainer [Funktionale Nanomaterialien, Institut fuer Materialwissenschaft, CAU Kiel Kaiserstr. 2 24143 Kiel (Germany); Yang, Bin [Klinik fuer Zahnaerztliche Prothetik, Propaedeutik und Werkstoffkunde, Arnold-Heller-Strasse 16, 24105 Kiel (Germany); Groessner-Schreiber, Birte [Klinik fuer Zahnerhaltungskunde und Parodontologie, Arnold-Heller-Str. 16, 24105 Kiel (Germany)

    2008-07-01

    Microbial adherence to dental implant surfaces is one initiating step in the formation of plaque and is considered to be an important event in the pathogenesis of peri-implant disease. Besides good connective tissue adhesion in the transmucosal part of an implant, titanium implants exposed to the oral cavity require surface modification to inhibit the adherence of oral bacteria. Surface roughness and chemical composition of the implant surface were found to have a significant impact on plaque formation. The aim of the present study was to examine bacterial adherence of differently modified potential implant surfaces. Therefore the surface roughness was decreased and for example a thin ceramic or composite layer of antibacterial material was deposited on abutment surface by sputtering. We analyze the new surface with AFM to control the roughness. For further characterization contact angle measurements were carried out. Biocompatibility and antibacterial effects will be determined in cooperation with the dental clinic at the University Kiel.

  9. Refining experimental dental implant testing in the Göttingen Minipig using 3D computed tomography-A morphometric study of the mandibular canal.

    Directory of Open Access Journals (Sweden)

    Giuliano M Corte

    Full Text Available This study reports morphometric and age-related data of the mandibular canal and the alveolar ridge of the Göttingen Minipig to avoid complications during in vivo testing of endosseus dental implants and to compare these data with the human anatomy. Using 3D computed tomography, six parameters of the mandibular canal as well as the alveolar bone height and the alveolar ridge width were measured in Göttingen Minipigs aged 12, 17 and 21 months. Our null hypothesis assumes that the age and the body mass have an influence on the parameters measured. The study found that the volume, length and depth of the mandibular canal all increase with age. The width of the canal does not change significantly with age. The body mass does not have an influence on any of the measured parameters. The increase in canal volume appears to be due to loss of deep spongy bone in the posterior premolar and molar regions. This reduces the available space for dental implantations, negatively affecting implant stability and potentially the integrity of the inferior alveolar neurovascular bundle. Dynamic anatomical changes occur until 21 months. On ethical grounds, using minipigs younger than 21 months in experimental implant dentistry is inadvisable. Paradoxically the measurements of the 12 months old pigs indicate a closer alignment of their mandibular anatomy to that of humans suggesting that they may be better models for implant studies. Given the variability in mandibular canal dimensions in similar age cohorts, the use of imaging techniques is essential for the selection of individual minipigs for dental prosthetic interventions and thus higher success rates.

  10. Computerized axial tomography : the tool in osseointegrated dental implants

    International Nuclear Information System (INIS)

    Fernandez-Lopez, Otton

    2002-01-01

    Failure rates in rehabilitations with osseointegrated implants are handled through appropriate radiographic preoperative planning. The appropriate length of the implant without running the risk of a perforation of vital structures, has been determined by a radiographic diagnosis. Computerized and conventional axial tomography have proved to be invaluable elements for pre-surgical evaluation. A radiologic guidance is elaborated to perform a computerized axial tomography (CT) of maxillary bones in totally edentulous patients. Surgical guides are constructed from a wax-up emanated from the information of the CT. The CT has proven to be an radiographic indispensable element to achieve the surgical-prosthetic success in osseointegrated dental implants. The CT has allowed the realization of a precise wax-up for making of surgical guide and a precise temporary prostheses in positioning of osseointegrated implants, with the consequent saving time and money for the rehabilitator and patient [es

  11. Effect of Polyvinyl Siloxane Viscosity on Accuracy of Dental Implant Impressions

    OpenAIRE

    Ghahremanloo, Ahmad; Seifi, Mahdieh; Ghanbarzade, Jalil; Abrisham, Seyyed Mohammad; Javan, Rashid Abdolah

    2017-01-01

    Objectives: The aim of this study was to compare the accuracy of dental implant impressions obtained by a combination of different impression techniques and viscosities of polyvinyl siloxane (PVS).Materials and Methods: Four parallel fixtures were placed between mental foramina in a master model of lower dental arch. Three different viscosities (putty/light body, medium body/light body, and monophase: heavy body) and direct and indirect techniques (six groups) were used, and seven impressions...

  12. Survival of dental implants in native and grafted bone in irradiated head and neck cancer patients: a retrospective analysis.

    Science.gov (United States)

    Buddula, Aravind; Assad, Daniel A; Salinas, Thomas J; Garces, Yolanda I

    2011-01-01

    To study the long-term survival of dental implants placed in native or grafted bone in irradiated bone in subjects who had received radiation for head and neck cancer. A retrospective chart review was conducted for all patients who received dental implants following radiation treatment for head and neck cancer between May 1, 1987 and July 1, 2008. Only patients irradiated with a radiation dose of 50 Gy or greater and those who received dental implants in the irradiated field after head and neck radiation were included in the study. The associations between implant survival and patient/implant characteristics were estimated by fitting univariate marginal Cox proportional hazards models. A total of 48 patients who had prior head and neck radiation had 271 dental implants placed during May 1987-July 2008. There was no statistically significant difference between implant failure in native and grafted bone (P=0.76). Survival of implants in grafted bone was 82.3% and 98.1% in maxilla and mandible, respectively, after 3 years. Survival of implants in native bone in maxilla and mandible was 79.8% and 100%, respectively, after 3 years. For implants placed in the native bone, there was a higher likelihood of failure in the maxilla compared to the mandible and there was also a tendency for implants placed in the posterior region to fail compared to those placed in the anterior region. There was no significant difference in survival when implants were placed in native or grafted bone in irradiated head and neck cancer patients. For implants placed in native bone, survival was significantly influenced by the location of the implant (maxilla or mandible, anterior or posterior).

  13. A systematic review on the long-term success of calcium phosphate plasma-spray-coated dental implants.

    Science.gov (United States)

    van Oirschot, B A J A; Bronkhorst, E M; van den Beucken, J J J P; Meijer, G J; Jansen, J A; Junker, R

    2016-09-01

    The objectives of the current review were (1) to systematically appraise, and (2) to evaluate long-term success data of calcium phosphate (CaP) plasma-spray-coated dental implants in clinical trials with at least 5 years of follow-up. To describe the long-term efficacy of functional implants, the outcome variables were (a) percentage annual complication rate (ACR) and (b) cumulative success rate (CSR), as presented in the selected articles. The electronic search yielded 645 titles. On the basis of the inclusion criteria, 8 studies were finally included. The percentage of implants in function after the first year was estimated to be 98.4 % in the maxilla and 99.2 % in the mandible. The estimates of the weighted mean ACR-percentage increased over the years up to 2.6 (SE 0.7) during the fifth year of function for the maxilla and to 9.4 (SE 8.4) for the mandible in the tenth year of function. After 10 years, the mean percentage of successful implants was estimated to be 71.1 % in the maxilla and 72.2 % in the mandible. The estimates seem to confirm the proposed, long-term progressive bone loss pattern of CaP-ceramic-coated dental implants. Within the limits of this meta-analytic approach to the literature, we conclude that: (1) published long-term success data for calcium phosphate plasma-spray-coated dental implants are limited, (2) comparison of the data is difficult due to differences in success criteria among the studies, and (3) long-term CSRs demonstrate very weak evidence for progressive complications around calcium phosphate plasma-spray-coated dental implants.

  14. Clinical evidence on titanium-zirconium dental implants: a systematic review and meta-analysis.

    Science.gov (United States)

    Altuna, P; Lucas-Taulé, E; Gargallo-Albiol, J; Figueras-Álvarez, O; Hernández-Alfaro, F; Nart, J

    2016-07-01

    The use of titanium implants is well documented and they have high survival and success rates. However, when used as reduced-diameter implants, the risk of fracture is increased. Narrow diameter implants (NDIs) of titanium-zirconium (Ti-Zr) alloy have recently been developed (Roxolid; Institut Straumann AG). Ti-Zr alloys (two highly biocompatible materials) demonstrate higher tensile strength than commercially pure titanium. The aim of this systematic review was to summarize the existing clinical evidence on dental NDIs made from Ti-Zr. A systematic literature search was performed using the Medline database to find relevant articles on clinical studies published in the English language up to December 2014. Nine clinical studies using Ti-Zr implants were identified. Overall, 607 patients received 922 implants. The mean marginal bone loss was 0.36±0.06mm after 1 year and 0.41±0.09mm after 2 years. The follow-up period ranged from 3 to 36 months. Mean survival and success rates were 98.4% and 97.8% at 1 year after implant placement and 97.7% and 97.3% at 2 years. Narrow diameter Ti-Zr dental implants show survival and success rates comparable to regular diameter titanium implants (>95%) in the short term. Long-term follow-up clinical data are needed to confirm the excellent clinical performance of these implants. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  15. Assessment and Evaluation of Quality of Life (OHRQoL) of Patients with Dental Implants Using the Oral Health Impact Profile (OHIP-14) - A Clinical Study.

    Science.gov (United States)

    Alzarea, Bader K

    2016-04-01

    Peri-implant tissue health is a requisite for success of dental implant therapy. Plaque accumulation leads to initiation of gingivitis around natural teeth and peri-implantitis around dental implants. Peri-implantitis around dental implants may result in implant placement failure. For obtaining long-term success, timely assessment of dental implant site is mandatory. To assess and evaluate Quality of Life (OHRQoL) of individuals with dental implants using the Oral Health Impact Profile (OHIP-14). Total 92 patients were evaluated for assessment of the health of peri-implant tissues by recording, Plaque Index (PI), Probing Pocket Depth (PD), Bleeding On Probing (BOP) and Probing Attachment Level (PAL) as compared to contra-lateral natural teeth (control). In the same patients Quality of Life Assessment was done by utilizing Oral Health Impact Profile Index (OHIP-14). The mean plaque index around natural teeth was more compared to implants and it was statistically significant. Other three dimensions mean bleeding on probing; mean probing attachment level and mean pocket depth around both natural teeth and implant surfaces was found to be not statistically significant. OHIP-14 revealed that patients with dental implants were satisfied with their Oral Health-Related Quality of Life (OHRQoL). Similar inflammatory conditions are present around both natural teeth and implant prostheses as suggested by results of mean plaque index, mean bleeding on probing, mean pocket depth and mean probing attachment level, hence reinforcing the periodontal health maintenance both prior to and after incorporation of dental implants. Influence of implant prostheses on patient's oral health related quality of life (as depicted by OHIP-14) and patients' perceptions and expectations may guide the clinician in providing the best implant services.

  16. Esthetic outcome for maxillary anterior single implants assessed by different dental specialists.

    Science.gov (United States)

    Al-Dosari, Abdullah; Al-Rowis, Ra'ed; Moslem, Feras; Alshehri, Fahad; Ballo, Ahmed M

    2016-10-01

    The aim of this study was to assess the esthetic outcome of maxillary anterior single implants by comparing the esthetic perception of dental professionals and patients. Twenty-three patients with single implants in the esthetic zone were enrolled in this study. Dentists of four different dental specialties (Three orthodontists, three oral surgeons, three prosthodontists, and three periodontists) evaluated the pink esthetic score (PES)/white esthetic score (WES) for 23 implant-supported single restorations. The satisfactions of the patients on the esthetic outcome of the treatment have been evaluated according to the visual analog scale (VAS). The mean total PES/WES was 12.26 ± 4.76. The mean PES was 6.45 ± 2.78 and mean WES was 5.80 ± 2.82. There was a statistically significant difference among the different specialties for WES ( P esthetic perception, thereby providing rationales for involving patients in the treatment plan to achieve higher levels of patient satisfaction.

  17. [Manufacture method and clinical application of minimally invasive dental implant guide template based on registration technology].

    Science.gov (United States)

    Lin, Zeming; He, Bingwei; Chen, Jiang; D u, Zhibin; Zheng, Jingyi; Li, Yanqin

    2012-08-01

    To guide doctors in precisely positioning surgical operation, a new production method of minimally invasive implant guide template was presented. The mandible of patient was scanned by CT scanner, and three-dimensional jaw bone model was constructed based on CT images data The professional dental implant software Simplant was used to simulate the plant based on the three-dimensional CT model to determine the location and depth of implants. In the same time, the dental plaster models were scanned by stereo vision system to build the oral mucosa model. Next, curvature registration technology was used to fuse the oral mucosa model and the CT model, then the designed position of implant in the oral mucosa could be determined. The minimally invasive implant guide template was designed in 3-Matic software according to the design position of implant and the oral mucosa model. Finally, the template was produced by rapid prototyping. The three-dimensional registration technology was useful to fuse the CT data and the dental plaster data, and the template was accurate that could provide the doctors a guidance in the actual planting without cut-off mucosa. The guide template which fabricated by comprehensive utilization of three-dimensional registration, Simplant simulation and rapid prototyping positioning are accurate and can achieve the minimally invasive and accuracy implant surgery, this technique is worthy of clinical use.

  18. Virtual planning of dental implant placement using CT double scan-technique - own experience

    International Nuclear Information System (INIS)

    Wojciechowski, W.; Urbanik, A.; Kownacki, P.; Kownacki, S.

    2007-01-01

    The correctness of CT performed with the use of a double-scan technique is the basis for achieving proper quality of 3D reconstructions of the maxilla or mandible and subsequent virtual planning of dental implant placement. The aim of this study was the presentation of the methodology of computed tomography scanning and own experience with the use of the double-scan technique. The study group included 26 individuals who underwent MDCT with a double-scan technique using a MDCT scanner SOMATOM Sensation (Siemens, Germany). The parameters of the examination: slice-collimation 10 x 0.75 mm, slice-thickness 0.75 mm. The first CT scan in the procedure was the scan of the patient wearing a radiological prosthesis and occlusal index, which was followed by a separate scan of the radiological prosthesis. These two CT scans were copied and transferred to PC with Procera Software program (Nobel Biocare, Sweden) where dental implant placement was virtually planned. In all 26 patients, precise three-dimensional reconstructions of the anatomical structure were obtained. In 11 patients, on the basis of the virtual planning, the implant placement was performed, 5 patients were referred to preparatory procedures, that is, restoration of the alveolar process, otolaryngological treatment of the maxillary sinuses. The remaining 10 patients did not qualify to the procedure because of unfavorable anatomical ideation's. Correct computed tomography with double-scan technique enables virtual planning of dental implant placement, on the basis of which the real procedure of implantation can be performed. (author)

  19. Voxel-based registration of simulated and real patient CBCT data for accurate dental implant pose estimation

    Science.gov (United States)

    Moreira, António H. J.; Queirós, Sandro; Morais, Pedro; Rodrigues, Nuno F.; Correia, André Ricardo; Fernandes, Valter; Pinho, A. C. M.; Fonseca, Jaime C.; Vilaça, João. L.

    2015-03-01

    The success of dental implant-supported prosthesis is directly linked to the accuracy obtained during implant's pose estimation (position and orientation). Although traditional impression techniques and recent digital acquisition methods are acceptably accurate, a simultaneously fast, accurate and operator-independent methodology is still lacking. Hereto, an image-based framework is proposed to estimate the patient-specific implant's pose using cone-beam computed tomography (CBCT) and prior knowledge of implanted model. The pose estimation is accomplished in a threestep approach: (1) a region-of-interest is extracted from the CBCT data using 2 operator-defined points at the implant's main axis; (2) a simulated CBCT volume of the known implanted model is generated through Feldkamp-Davis-Kress reconstruction and coarsely aligned to the defined axis; and (3) a voxel-based rigid registration is performed to optimally align both patient and simulated CBCT data, extracting the implant's pose from the optimal transformation. Three experiments were performed to evaluate the framework: (1) an in silico study using 48 implants distributed through 12 tridimensional synthetic mandibular models; (2) an in vitro study using an artificial mandible with 2 dental implants acquired with an i-CAT system; and (3) two clinical case studies. The results shown positional errors of 67+/-34μm and 108μm, and angular misfits of 0.15+/-0.08° and 1.4°, for experiment 1 and 2, respectively. Moreover, in experiment 3, visual assessment of clinical data results shown a coherent alignment of the reference implant. Overall, a novel image-based framework for implants' pose estimation from CBCT data was proposed, showing accurate results in agreement with dental prosthesis modelling requirements.

  20. Improved dental implant drill durability and performance using heat and wear resistant protective coatings.

    Science.gov (United States)

    Er, Nilay; Alkan, Alper; İlday, Serim; Bengu, Erman

    2018-03-02

    Dental implant drilling procedure is an essential step for implant surgery and frictional heat appeared in bone during drilling is a key factor affecting the success of an implant. The aim of this study is to increase the dental implant drill lifetime and performance using heat- and wear-resistant protective coatings hence to decrease the alveolar bone temperature caused by the dental implant drilling procedure. Commercially obtained stainless steel drills were coated with titanium aluminum nitride, diamond-like carbon, titanium boron nitride, and boron nitride coatings via magnetron-sputter deposition. Drilling procedure was performed on a bovine femoral cortical bone under the conditions mimicking clinical practice, where the tests were performed both under water-assisted cooling and under the conditions without any cooling was applied. Coated drill performances and durabilities were compared to that of three commonly used commercial drills which surfaces are made from namely; zirconia, black diamond and stainless steel. Protective coatings with boron nitride, titanium boron nitride and diamond-like carbon have significantly improved drill performance and durability. Especially boron nitride-coated drills have performed within safe bone temperature limits for 50 drillings even without any cooling is applied. Titanium aluminium nitride coated drills did not show any improvement over commercially obtained stainless steel drills. Surface modification using heat and wear resistant coatings is an easy and highly effective way to improve implant drill performance and durability, which can reflect positively on surgical procedure and healing period afterwards. The noteworthy success of different types of coatings is novel and likely to be applicable to various other medical systems.

  1. Survival of dental implants in native and grafted bone in irradiated head and neck cancer patients: A retrospective analysis

    Directory of Open Access Journals (Sweden)

    Aravind Buddula

    2011-01-01

    Full Text Available Aim: To study the long-term survival of dental implants placed in native or grafted bone in irradiated bone in subjects who had received radiation for head and neck cancer. Materials and Methods: A retrospective chart review was conducted for all patients who received dental implants following radiation treatment for head and neck cancer between May 1, 1987 and July 1, 2008. Only patients irradiated with a radiation dose of 50 Gy or greater and those who received dental implants in the irradiated field after head and neck radiation were included in the study. The associations between implant survival and patient/implant characteristics were estimated by fitting univariate marginal Cox proportional hazards models. Results: A total of 48 patients who had prior head and neck radiation had 271 dental implants placed during May 1987-July 2008. There was no statistically significant difference between implant failure in native and grafted bone (P=0.76. Survival of implants in grafted bone was 82.3% and 98.1% in maxilla and mandible, respectively, after 3 years. Survival of implants in native bone in maxilla and mandible was 79.8% and 100%, respectively, after 3 years. For implants placed in the native bone, there was a higher likelihood of failure in the maxilla compared to the mandible and there was also a tendency for implants placed in the posterior region to fail compared to those placed in the anterior region. Conclusion: There was no significant difference in survival when implants were placed in native or grafted bone in irradiated head and neck cancer patients. For implants placed in native bone, survival was significantly influenced by the location of the implant (maxilla or mandible, anterior or posterior.

  2. Influence of different implant materials on the primary stability of orthodontic mini-implants

    OpenAIRE

    Chin-Yun Pan; Szu-Ting Chou; Yu-Chuan Tseng; Yi-Hsin Yang; Chao-Yi Wu; Ting-Hsun Lan; Pao-Hsin Liu; Hong-Po Chang

    2012-01-01

    This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants w...

  3. Idiopathic facial pain related with dental implantation

    Directory of Open Access Journals (Sweden)

    Tae-Geon Kwon

    2016-06-01

    Full Text Available Chronic pain after dental implantation is rare but difficult issue for the implant practitioner. Patients with chronic pain who had been performed previous implant surgery or related surgical intervention sometimes accompany with psychological problem and difficult to adequately manage. According to the International Classification of Headache Disorders (ICHD 3rd eds, Cepalagia 2013, painful neuropathies and other facial pains are subdivided into the 12 subcategories; 13.1. Trigeminal neuralgia; 13.2 Glossopharyngeal neuralgia; 13.3 Nervus intermedius (facial nerve neuralgia; 13.4 Occipital neuralgia; 13.5 Optic neuritis; 13.6 Headache attributed to ischaemic ocular motor nerve palsy; 13.7 Tolosa-Hunt syndrome; 13.8 Paratrigeminal oculo-sympathetic (Raeder’s syndrome; 13.9 Recurrent painful ophthalmoplegic neuropathy; 13.10 Burning Mouth Syndrome (BMS; 13.11 Persistent Idiopathic Facial Pain (PIFP; 13.12 Central neuropathic pain. Chronic orofacial pain after dental implant surgery can be largely into the two main categories that can be frequently encountered in clinical basis ; 1 Neuropathic pain, 2 Idiopathic pain. If there is no direct evidence of the nerve injury related with the implant surgery, the clinician need to consider the central cause of pain instead of the peripheral cause of the pain. There might be several possibilities; 1 Anaesthesia dolorosa, 2 Central post-stroke pain, 3 Facial pain attributed to multiple sclerosis, 4 Persistent idiopathic facial pain (PIFP, 5 Burning mouth syndrome. In this presentation, Persistent idiopathic facial pain (PIFP, the disease entity that can be frequently encountered in the clinic would be discussed. Persistent idiopathic facial pain (PIFP can be defined as “persistent facial and/or oral pain, with varying presentations but recurring daily for more than 2 hours per day over more than 3 months, in the absence of clinical neurological deficit”. ‘Atypical’ pain is a diagnosis of

  4. Clinico-statistical study of preoperative examination for the dental implant using multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Sekiya, Keiko; Mori, Shintaro; Sekiya, Kotaro

    2008-01-01

    In April 2006, a new affiliated hospital opened at Nihon University School of Dentistry at Matsudo, and the latest model was introduced into the department of radiology. CT examinations for preoperative dental implant going on 64 multi-detector row CT, the number of cases has increased. CT examination is useful for preoperative dental implant, and many studies of concerning clinical studies using CT images have been reported. The purpose of this study was to the clinico-statistical studies of preoperative CT examinations for dental implant at our radiology department using 64 multi-detector row CT. The subjects consisted of 5174 regions in 1312 cases of preoperative CT examinations, between April 2006 and December 2007. CT machine used was the Aquilion TM 64 (Toshiba Medical Systems, Japan), and the workstation used was the ZIOSTATION (ZIOSOFT, Japan). All of CT examinations were performed the position of implant placement and disease examined from CT findings. The following results were obtained: The 1312 cases consisted of 426 males and 886 females. Patient age ranged from 16 yrs to 86 yrs old, the average age were 55.5 yrs old. Six hundred and seventy four cases were ordered at another private dental office not our hospital, and 638 cases were ordered at our hospital. The numbers of implant placement were on the average of 3.9, and the rate got higher with age. The lesions which detected by preoperative CT examination were maxillary sinusitis, periodontitis, ectopic calcification, and mucous retention cyst. (author)

  5. Metallic ion content and damage to the DNA in oral mucosa cells patients treated dental implants.

    Science.gov (United States)

    López-Jornet, Pía; Perrez, Francisco Parra; Calvo-Guirado, José Luis; Ros-Llor, Irene; LLor-Ros, Irene; Ramírez-Fernández, Piedad

    2014-07-01

    The aim of this study was to assess the potential genotoxicity of dental implants, evaluating biomarkers of DNA damage (micronuclei and/or nuclear buds), cytokinetic defects (binucleated cells) and the presence of trace metals in gingival cells of patients with implants, comparing these with a control group. A total of 60 healthy adults (30 patients with dental implants and 30 control patients without) were included in the study. Medical and dental histories were made for each including life-style factors. Genotoxicity effects were assessed by micronucleus assays in the gingival epithelial cells of each patient; 1,000 epithelial cells were analyzed, evaluating the frequency of micronucleated cells and other nuclear anomalies. The concentration of metals (Al(27), Ag(107), Co (59), Cr (52), Cu(63), Fe(56), Sn(118), Mn(55), Mo(92), Ni(60), Pb(208), Ti(47)) were assayed by means of coupled plasma-mass spectrophotometry (ICP-MS). The frequency of micronuclei in the patient group with implants was higher than in the control group but without statistically significant differences (P > 0.05). Similar results were found for binucleated cells and nuclear buds (P > 0.05). For metals assayed by ICP-MS, significant differences were found for Ti(47) (P ≤ 0.045). Univariate analysis identified a significant association between the presence of micronuclei and age. Dental implants do not induce DNA damage in gingival cells, the slight effects observed cannot be indicated as biologically relevant.

  6. Bruxism: overview of current knowledge and suggestions for dental implants planning

    NARCIS (Netherlands)

    Manfredini, D.; Bucci, M.B.; Sabattini, V.B.; Lobbezoo, F.

    2011-01-01

    Bruxism is commonly considered a detrimental motor activity, potentially causing overload of the stomatognathic structures and representing a risk factor for dental implant survival. The available literature does not provide evidence-based guidelines for the management of bruxers undergoing

  7. Alveolar Bone Resorption Evaluation Around Single-piece Designed Bicortical Implants, Using Immediate Loading Protocol, Based on Orthopantomographs

    Directory of Open Access Journals (Sweden)

    Száva Dániel-Tamás

    2017-12-01

    Full Text Available Background: Inserting dental implants in severely atrophied jawbones is a great challenge for the dental practitioner. There are an increasing number of patients who choose dental implantanchored prosthetic restorations despite compromised bone quality and quantity. There have been numerous attempts in adapting implant design for the atrophic crestal bone. One-piece, needle-type basal implant design is a typical design for these cases. These implants are inserted in the remaining compact bone located in the basal aspect of the jawbones. If high primary stability is achieved, these implants are used for immediate loading protocol. From many points of view, this technique is based on contradictory principles compared to classic implant surgery and loading protocols. The aim of this study was to investigate the long-term success of basal one-piece short-diameter dental implants used for immediate loading protocol.

  8. Noninvasive method for retrieval of broken dental implant abutment screw

    Directory of Open Access Journals (Sweden)

    Jagadish Reddy Gooty

    2014-01-01

    Full Text Available Dental implants made of titanium for replacement of missing teeth are widely used because of ease of technical procedure and high success rate, but are not free of complications and may fail. Fracturing of the prosthetic screw continues to be a problem in restorative practice and great challenge to remove the fractured screw conservatively. This case report describes and demonstrates the technique of using an ultrasonic scaler in the removal of the fracture screw fragment as a noninvasive method without damaging the hex of implants.

  9. Oral rehabilitation of segmental mandibulectomy patient with osseointegrated dental implant

    Directory of Open Access Journals (Sweden)

    Archana Singh

    2014-01-01

    Full Text Available Surgical management of oral cancer lesions results in explicit aesthetic and functional disfigurement, including facial deformity, loss of hard and soft tissue, impaired speech, swallowing and mastication, which modify the patient′s self-image and quality-of-life. Recent advances in head and neck reconstruction techniques and dental implant based prosthetic rehabilitation may significantly improve the quality-of-life and self-esteem for such post-surgery patients. This clinical report describes rehabilitation of oral cancer patient having segmental mandibulectomy with implant-supported fixed partial denture.

  10. The analysis of cost-effectiveness of implant and conventional fixed dental prosthesis.

    Science.gov (United States)

    Chun, June Sang; Har, Alix; Lim, Hyun-Pil; Lim, Hoi-Jeong

    2016-02-01

    This study conducted an analysis of cost-effectiveness of the implant and conventional fixed dental prosthesis (CFDP) from a single treatment perspective. The Markov model for cost-effectiveness analysis of the implant and CFDP was carried out over maximum 50 years. The probabilistic sensitivity analysis was performed by the 10,000 Monte-Carlo simulations, and cost-effectiveness acceptability curves (CEAC) were also presented. The results from meta-analysis studies were used to determine the survival rates and complication rates of the implant and CFDP. Data regarding the cost of each treatment method were collected from University Dental Hospital and Statistics Korea for 2013. Using the results of the patient satisfaction survey study, quality-adjusted prosthesis year (QAPY) of the implant and CFDP strategy was evaluated with annual discount rate. When only the direct cost was considered, implants were more cost-effective when the willingness to pay (WTP) was more than 10,000 won at 10(th) year after the treatment, and more cost-effective regardless of the WTP from 20(th) year after the prosthodontic treatment. When the indirect cost was added to the direct cost, implants were more cost-effective only when the WTP was more than 75,000 won at the 10(th) year after the prosthodontic treatment, more than 35,000 won at the 20(th) year after prosthodontic treatment. The CFDP was more cost-effective unless the WTP was more than 75,000 won at the 10(th) year after prosthodontic treatment. But the cost-effectivenss tendency changed from CFDP to implant as time passed.

  11. Tantalum, Niobium and Titanium Coatings for Biocompatibility Improvement of Dental Implants

    Directory of Open Access Journals (Sweden)

    Vajihesadat Mortazavi

    2007-01-01

    Full Text Available Introduction: Metals have a wide range of applications in implant and prosthetic materials in dentistry.Corrosion resistance and biocompatibility of metals should be improved in order to utilizethem as biomaterials. The aim of this work was to prepare metallic coatings on 316L stainless steel dental implants, to evaluate the corrosion characteristics of the uncoated and metallic coated dentalimplants as an indication of biocompatibility and, to compare the effect of the type of the coatings on biocompatibility.Materials and Methods: In this in vitro evaluation, three types of metallic coatings including tantalum, niobium and titanium coatings were compared using a physical vapor deposition process on 316L stainless steel dental implants. Structural characterization techniques including X-ray diffraction, scanning electron microscopy and energy dispersive X-ray analysis were utilized to investigatethe microstructure and morphology of the coatings. Electrochemical potentiodynamic tests were performed in two types of physiological solutions at 37±1°C in order to determine and compare the corrosioncurrent density and corrosion potential characteristics. The mean values were statistically compared by ANOVA at a 95% level of confidence.Results: the findings showed that all of the three types of metallic coatings had a positive effect on improvement of the corrosion behavior. The coatings could increase the corrosion resistance of 316L stainless steel and this trend was independent of the type of physiological environment.Conclusion: The biocompatible metallic coatings could decrease the corrosion current density and is a distinct advantage for prevention of ion release. Decreasing ion release can improve the biocompatibility of the dental implant, and consequently can prevent tissue damage, tissue inflammation and irritation, and can also lead to obtaining a desirable histopathological response.

  12. Random spectrum loading of dental implants: An alternative approach to functional performance assessment.

    Science.gov (United States)

    Shemtov-Yona, K; Rittel, D

    2016-09-01

    The fatigue performance of dental implants is usually assessed on the basis of cyclic S/N curves. This neither provides information on the anticipated service performance of the implant, nor does it allow for detailed comparisons between implants unless a thorough statistical analysis is performed, of the kind not currently required by certification standards. The notion of endurance limit is deemed to be of limited applicability, given unavoidable stress concentrations and random load excursions, that all characterize dental implants and their service conditions. We propose a completely different approach, based on random spectrum loading, as long used in aeronautical design. The implant is randomly loaded by a sequence of loads encompassing all load levels it would endure during its service life. This approach provides a quantitative and comparable estimate of its performance in terms of lifetime, based on the very fact that the implant will fracture sooner or later, instead of defining a fatigue endurance limit of limited practical application. Five commercial monolithic Ti-6Al-4V implants were tested under cyclic, and another 5 under spectrum loading conditions, at room temperature and dry air. The failure modes and fracture planes were identical for all implants. The approach is discussed, including its potential applications, for systematic, straightforward and reliable comparisons of various implant designs and environments, without the need for cumbersome statistical analyses. It is believed that spectrum loading can be considered for the generation of new standardization procedures and design applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Anatomic Customization of Root-Analog Dental Implants With Cone-Beam CT and CAD/CAM Fabrication: A Cadaver-Based Pilot Evaluation.

    Science.gov (United States)

    Evans, Zachary P; Renne, Walter G; Bacro, Thierry R; Mennito, Anthony S; Ludlow, Mark E; Lecholop, Michael K

    2018-02-01

    Existing root-analog dental implant systems have no standardized protocols regarding retentive design, surface manipulation, or prosthetic attachment design relative to the site's unique anatomy. Historically, existing systems made those design choices arbitrarily. For this report, strategies were developed that deliberately reference the adjacent anatomy, implant and restorable path of draw, and bone density for implant and retentive design. For proof of concept, dentate arches from human cadavers were scanned using cone-beam computed tomography and then digitally modeled. Teeth of interest were virtually extracted and manipulated via computer-aided design to generate root-analog implants from zirconium. We created a stepwise protocol for analyzing and developing the implant sites, implant design and retention, and prosthetic emergence and connection all from the pre-op cone-beam data. Root-analog implants were placed at the time of extraction and examined radiographically and mechanically concerning ideal fit and stability. This study provides proof of concept that retentive root-analog implants can be produced from cone-beam data while improving fit, retention, safety, esthetics, and restorability when compared to the existing protocols. These advancements may provide the critical steps necessary for clinical relevance and success of immediately placed root-analog implants. Additional studies are necessary to validate the model prior to clinical trial.

  14. Evaluation of MRI artifacts caused by metallic dental implants and classification of the dental materials in use

    Czech Academy of Sciences Publication Activity Database

    Starčuk jr., Zenon; Bartušek, Karel; Hubálková, H.; Bachorec, T.; Starčuková, Jana; Krupa, P.

    2006-01-01

    Roč. 6, č. 2 (2006), s. 24-27 ISSN 1335-8871 R&D Projects: GA MZd NR8110 Institutional research plan: CEZ:AV0Z20650511 Keywords : magnetic resonance imaging * artifacts * metallic implants * dental alloys * magnetic susceptibility Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  15. 3D Printing/Additive Manufacturing Single Titanium Dental Implants: A Prospective Multicenter Study with 3 Years of Follow-Up.

    Science.gov (United States)

    Tunchel, Samy; Blay, Alberto; Kolerman, Roni; Mijiritsky, Eitan; Shibli, Jamil Awad

    2016-01-01

    This prospective 3-year follow-up clinical study evaluated the survival and success rates of 3DP/AM titanium dental implants to support single implant-supported restorations. After 3 years of loading, clinical, radiographic, and prosthetic parameters were assessed; the implant survival and the implant-crown success were evaluated. Eighty-two patients (44 males, 38 females; age range 26-67 years) were enrolled in the present study. A total of 110 3DP/AM titanium dental implants (65 maxilla, 45 mandible) were installed: 75 in healed alveolar ridges and 35 in postextraction sockets. The prosthetic restorations included 110 single crowns (SCs). After 3 years of loading, six implants failed, for an overall implant survival rate of 94.5%; among the 104 surviving implant-supported restorations, 6 showed complications and were therefore considered unsuccessful, for an implant-crown success of 94.3%. The mean distance between the implant shoulder and the first visible bone-implant contact was 0.75 mm (±0.32) and 0.89 (±0.45) after 1 and 3 years of loading, respectively. 3DP/AM titanium dental implants seem to represent a successful clinical option for the rehabilitation of single-tooth gaps in both jaws, at least until 3-year period. Further, long-term clinical studies are needed to confirm the present results.

  16. 3D Printing/Additive Manufacturing Single Titanium Dental Implants: A Prospective Multicenter Study with 3 Years of Follow-Up

    Directory of Open Access Journals (Sweden)

    Samy Tunchel

    2016-01-01

    Full Text Available This prospective 3-year follow-up clinical study evaluated the survival and success rates of 3DP/AM titanium dental implants to support single implant-supported restorations. After 3 years of loading, clinical, radiographic, and prosthetic parameters were assessed; the implant survival and the implant-crown success were evaluated. Eighty-two patients (44 males, 38 females; age range 26–67 years were enrolled in the present study. A total of 110 3DP/AM titanium dental implants (65 maxilla, 45 mandible were installed: 75 in healed alveolar ridges and 35 in postextraction sockets. The prosthetic restorations included 110 single crowns (SCs. After 3 years of loading, six implants failed, for an overall implant survival rate of 94.5%; among the 104 surviving implant-supported restorations, 6 showed complications and were therefore considered unsuccessful, for an implant-crown success of 94.3%. The mean distance between the implant shoulder and the first visible bone-implant contact was 0.75 mm (±0.32 and 0.89 (±0.45 after 1 and 3 years of loading, respectively. 3DP/AM titanium dental implants seem to represent a successful clinical option for the rehabilitation of single-tooth gaps in both jaws, at least until 3-year period. Further, long-term clinical studies are needed to confirm the present results.

  17. Prosthodontic rehabilitation of hypophosphatasia using dental implants: a review of the literature and two case reports.

    LENUS (Irish Health Repository)

    Lynch, C D

    2009-06-01

    There are reports in the literature of the various dental features of hypophosphatasia, especially where it affects the deciduous dentition. The descriptions include both the manifestations of the disorder and the subsequent patterns of tooth loss. There are fewer descriptions of the effects of hypophosphatasia on the permanent dentition and little information on the subsequent prosthodontic management of these patients, particularly in relation to the use of dental implants. The aim of this paper was to review the literature on the dental effects of hypophosphatasia, present two cases and describe how one of those patients, a young adult, was successfully rehabilitated using dental implants. That latter patient\\'s pattern of tooth loss as well as some histological and scanning electron microscopic findings of root cementum from the other case is also described.

  18. Application of high resolution synchrotron micro-CT radiation in dental implant osseointegration

    DEFF Research Database (Denmark)

    Neldam, Camilla Albeck; Lauridsen, Torsten; Rack, Alexander

    2015-01-01

    The purpose of this study was to describe a refined method using high-resolution synchrotron radiation microtomography (SRmicro-CT) to evaluate osseointegration and peri-implant bone volume fraction after titanium dental implant insertion. SRmicro-CT is considered gold standard evaluating bone...... microarchitecture. Its high resolution, high contrast, and excellent high signal-to-noise-ratio all contribute to the highest spatial resolutions achievable today. Using SRmicro-CT at a voxel size of 5 μm in an experimental goat mandible model, the peri-implant bone volume fraction was found to quickly increase...

  19. Effect of implant macro-design on primary stability: A prospective clinical study.

    Science.gov (United States)

    Lozano-Carrascal, Naroa; Salomó-Coll, Oscar; Gilabert-Cerdà, Marta; Farré-Pagés, Nuria; Gargallo-Albiol, Jordi; Hernández-Alfaro, Federico

    2016-03-01

    Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Mehods: A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers' standard protocols. Implant primary stability was measured at the moment of implant placement by registering insertion torque values (ITv) and ISQ values by means of Osstell™ Mentor (ISQv) (Integration Diagnostic Ltd., Goteborg, Sweden). In the mandible, mean ISQv for tapered implants (TI) was 71.67±5.16 and for cylindrical implants (CI) 57.15±4.83 (p=0.01). Mean insertion torque was 46.67±6.85 Ncm for TI and 35.77±6.72 Ncm for CI (p=0.01). In the maxilla, mean ISQ was 67.2±4.42 for tapered implants and 49.17±15.30 for cylindrical implants (p=0.01). Mean insertion torque for TI was 41.5±6.26 Ncm and for CI 39.17±6.34 Ncm (p>0.05). For tapered implants, no correlation could be found between implant diameter and primary stability. But for cylindrical implants there was a statistically significant correlation between implant diameter and primary stability: ITv (p=0.03); ISQv (p=0.04). Within the limits of the present study, tapered shaped implants achieve higher primary stability measured through ISQ and insertion torque values. Moreover, for cylindrical implants positive correlation has been established between implant diameter and primary stability.

  20. Pain from Dental Implant Placement, Inflammatory Pulpitis Pain, and Neuropathic Pain Present Different Somatosensory Profiles.

    Science.gov (United States)

    Porporatti, André Luís; Bonjardim, Leonardo Rigoldi; Stuginski-Barbosa, Juliana; Bonfante, Estevam Augusto; Costa, Yuri Martins; Rodrigues Conti, Paulo César

    2017-01-01

    To address the two following questions: (1) What kind of somatosensory abnormalities may be characterized in patients receiving dental implants (IMP), in ongoing inflammatory dental pulpitis (IP) patients, and in neuropathic pain (atypical odontalgia [AO]) patients? and (2) What sort of sensory and neural changes may result from dental implant placement surgery and pulpectomy? A total of 60 subjects were divided into three groups: the IMP (n = 20), IP (n = 20), and AO groups (n = 20). Quantitative sensory testing (QST) was performed preoperatively (baseline) for all three groups and postoperatively at 1 month and 3 months after dental implant placement or pulpectomy (in the IMP group and IP group, respectively). Statistical analyses were completed with one-way and two-way analysis of variance and z score transformations (α = 5%). The main findings of this study indicated that: (1) Elevations in mechanical detection threshold (MDT) and in current perception threshold (CPT) related to C-fiber activation, indicating a loss of function, were found at baseline in IP patients; (2) Somatosensory abnormalities such as allodynia, reduced MDT and mechanical pain threshold (MPT), and impaired pain modulation were found in AO patients; (3) No somatosensory alterations after implant placement were found in the IMP group; and (4) Somatosensory alterations in the form of reduction in the CPT related to C-fiber activation were reported 3 months after pulpectomy in the IP group. This study showed that somatosensory abnormalities were evident in AO and IP patients, and somatosensory alterations were seen in IP patients even 3 months after pulpectomy. However, no somatosensory alterations were seen after implant placement.

  1. Towards long lasting zirconia-based composites for dental implants: Transformation induced plasticity and its consequence on ceramic reliability.

    Science.gov (United States)

    Reveron, Helen; Fornabaio, Marta; Palmero, Paola; Fürderer, Tobias; Adolfsson, Erik; Lughi, Vanni; Bonifacio, Alois; Sergo, Valter; Montanaro, Laura; Chevalier, Jérôme

    2017-01-15

    Zirconia-based composites were developed through an innovative processing route able to tune compositional and microstructural features very precisely. Fully-dense ceria-stabilized zirconia ceramics (84vol% Ce-TZP) containing equiaxed alumina (8vol%Al 2 O 3 ) and elongated strontium hexa-aluminate (8vol% SrAl 12 O 19 ) second phases were obtained by conventional sintering. This work deals with the effect of the zirconia stabilization degree (CeO 2 in the range 10.0-11.5mol%) on the transformability and mechanical properties of Ce-TZP-Al 2 O 3 -SrAl 12 O 19 materials. Vickers hardness, biaxial flexural strength and Single-edge V-notched beam tests revealed a strong influence of ceria content on the mechanical properties. Composites with 11.0mol% CeO 2 or above exhibited the classical behaviour of brittle ceramics, with no apparent plasticity and very low strain to failure. On the contrary, composites with 10.5mol% CeO 2 or less showed large transformation-induced plasticity and almost no dispersion in strength data. Materials with 10.5mol% of ceria showed the highest values in terms of biaxial bending strength (up to 1.1GPa) and fracture toughness (>10MPa√m). In these ceramics, as zirconia transformation precedes failure, the Weibull modulus was exceptionally high and reached a value of 60, which is in the range typically reported for metals. The results achieved demonstrate the high potential of using these new strong, tough and stable zirconia-based composites in structural biomedical applications. Yttria-stabilized (Y-TZP) zirconia ceramics are increasingly used for developing metal-free restorations and dental implants. Despite their success related to their excellent mechanical resistance, Y-TZP can undergo Low Temperature Degradation which could be responsible for restoration damage or even worst the failure of the implant. Current research is focusing on strategies to improve the LTD resistance of Y-TZP or to develop alternative composites with better

  2. Mandibular Overdentures Supported by 6-mm Dental Implants : A 1-Year Prospective Cohort Study

    NARCIS (Netherlands)

    Gulje, Felix; Raghoebar, Gerry M.; Ter Meulen, Jan-Willem P.; Vissink, Arjan; Meijer, Henny J. A.; Guljé, Felix

    Background: The extremely resorbed edentulous mandible, with a bone height of 8 mm or less, is still a challenge in implant dentistry. Recently, dental implants of 6 mm in length have been developed. Purpose: The purpose of this 1-year prospective cohort study was to evaluate treatment outcome of

  3. Primary Stability of Zirconium vs Titanium Implants: An In Vitro Comparison

    Science.gov (United States)

    2015-06-05

    of any copyrighted material in the thesis manuscript entitled: Primary Stability of Zirconium vs Titanium Implants: An In Vitro Comparison Is...Uniformed Services University Date: 02/20/2015 Primary Stability of Zirconium vs Titanium Implants: An In Vitro Comparison By...the thesis manuscript entitled: Primary Stability of Zirconium vs Titanium Implants: An In Vitro Comparison Is appropriately acknowledged

  4. A study of the bone healing kinetics of plateau versus screw root design titanium dental implants.

    LENUS (Irish Health Repository)

    Leonard, Gary

    2009-03-01

    This study was designed to compare the bone healing process around plateau root from (PRF) and screw root from (SRF) titanium dental implants over the immediate 12 week healing period post implant placement.

  5. Long-term evaluation of hollow screw and hollow cylinder dental implants : Clinical and radiographic results after 10 years

    NARCIS (Netherlands)

    Telleman, Gerdien; Meijer, Henny J. A.; Raghoebar, Gerry M.

    Background: In 1988, an implant manufacturer offered a new dental implant system, with a wide choice of hollow cylinder (HC) and hollow screw (HS) implants. The purpose of this retrospective study of HS and HC implants was to evaluate clinical and radiographic parameters of peri-implant tissue and

  6. Evaluation of dental implants as a risk factor for the development of bisphosphonate-related osteonecrosis of the jaw in breast cancer patients.

    Science.gov (United States)

    Matsuo, Akira; Hamada, Hayato; Takahashi, Hidetoshi; Okamoto, Ayako; Kaise, Hiroshi; Chikazu, Daichi

    2016-09-01

    It remains unclear whether dental implants are a risk factor for the development of bisphosphonate-related osteonecrosis of the jaw (BRONJ). We retrospectively evaluated the status of dental implants in patients given intravenous bisphosphonates (BPs) in a breast cancer cohort to elucidate the risk for BRONJ at the implant site. We established a BRONJ oral monitoring program for 247 breast cancer patients given intravenous BP in our institution. The 3-year cumulative incidence rate was determined. The systemic and local risk factors of 44 patients who completed comprehensive oral examinations were evaluated by logistic regression analysis. The 3-year cumulative incidence rate of the 247 patients was 0.074 % (8/247, 95 % CI 0.0081-0.014). In the 44 orally examined patients, 6 (13.6 %: 6/44) had dental implants. Of these 6 patients, 1 developed BRONJ at the implant site. There were no significant differences in the age, total BP treatment period, number of residual teeth, time of regular oral monitoring, oral hygiene level, or dental implant insertion. Although a case of ONJ was identified, dental implants which were inserted before intravenous BP administration were not a risk factor for the development of ONJ in breast cancer patients.

  7. Oral Cancer around Dental Implants Appearing in Patients with\\without a History of Oral or Systemic Malignancy: a Systematic Review.

    Science.gov (United States)

    Pinchasov, Ginnady; Haimov, Haim; Druseikaite, Monika; Pinchasov, Daniel; Astramskaite, Inesa; Sarikov, Rafael; Juodzbalys, Gintaras

    2017-01-01

    The purpose of this article is to systematically review the circumstance of oral cancer around osseointegrated dental implants. An electronic literature search was conducted through the MEDLINE (PubMed) and EMBASE databases. The search was restricted for articles published during the last 21 years from January 1996 to April 2017 and articles were limited to English language. A total of 35 articles were reviewed, and 19 of the most relevant articles that are suitable to the criteria were selected. Case reports were analysed when oral cancer was present in patients with dental implants. Finally, the present data included 28 patients. A direct link between dental implants and oral cancer was not found. It was observed that there were no significant differences in number of incidences of oral cancer between patients with history of malignancy and those without. More research should be made to document such cases. It was noticed that in many cases oral cancer around dental implant present itself as peri-implantitis, correct differential diagnosis is essential in such cases.

  8. Dental Implant Macro-Design Features Can Impact the Dynamics of Osseointegration.

    Science.gov (United States)

    Vivan Cardoso, Marcio; Vandamme, Katleen; Chaudhari, Amol; De Rycker, Judith; Van Meerbeek, Bart; Naert, Ignace; Duyck, Joke

    2015-08-01

    The purpose of this study was to compare the clinical performance of two dental implant types possessing a different macro-design in the in vivo pig model. Titanium Aadva(TM) implants (GC, Tokyo, Japan) were compared with OsseoSpeed(TM) implants (Astra, Mölndal, Sweden), with the Aadva implant displaying significant larger inter-thread dimensions than the OsseoSpeed implant. Implants were installed in the parietal bone of 12 domestic pigs and left for healing for either 1 or 3 months. Implant osseointegration was evaluated by quantitative histology (bone volume relative to the tissue volume [BV/TV]; bone-to-implant contact [BIC]) for distinct implant regions (collar, body, total implant length) with specific implant thread features. The Wilcoxon-Mann-Whitney nonparametric test with α = 0.05 was performed. An inferior amount of bone enveloping the Aadva implant compared with the OsseoSpeed implant was observed, in particular at the implant body part with its considerable inter-thread gaps (p macro-design negatively affected the amount of bone in direct contact with the implant for this specific implant part (p implant osseointegration at the initial healing stage (total implant length; 1-month healing; p implant displayed a clinically acceptable level of osseointegration, the findings demonstrate that implant macro-design features can impact the dynamics of implant osseointegration. Consideration of specific implant macro-design features should be made relative to the biological and mechanical microenvironment. © 2013 Wiley Periodicals, Inc.

  9. Accuracy of a new elastomeric impression material for complete-arch dental implant impressions.

    Science.gov (United States)

    Baig, Mirza R; Buzayan, Muaiyed M; Yunus, Norsiah

    2018-05-01

    The aim of the present study was to assess the accuracy of multi-unit dental implant casts obtained from two elastomeric impression materials, vinyl polyether silicone (VPES) and polyether (PE), and to test the effect of splinting of impression copings on the accuracy of implant casts. Forty direct impressions of a mandibular reference model fitted with six dental implants and multibase abutments were made using VPES and PE, and implant casts were poured (N = 20). The VPES and PE groups were split into four subgroups of five each, based on splinting type: (a) no splinting; (b) bite registration polyether; (c) bite registration addition silicone; and (d) autopolymerizing acrylic resin. The accuracy of implant-abutment replica positions was calculated on the experimental casts, in terms of interimplant distances in the x, y, and z-axes, using a coordinate measuring machine; values were compared with those measured on the reference model. Data were analyzed using non-parametrical Kruskal-Wallis and Mann-Whitney tests at α = .05. The differences between the two impression materials, VPES and PE, regardless of splinting type, were not statistically significant (P>.05). Non-splinting and splinting groups were also not significantly different for both PE and VPES (P>.05). The accuracy of VPES impression material seemed comparable with PE for multi-implant abutment-level impressions. Splinting had no effect on the accuracy of implant impressions. © 2018 John Wiley & Sons Australia, Ltd.

  10. Novel implant design improves implant survival in multirooted extraction sites: a preclinical pilot study.

    Science.gov (United States)

    Sivan-Gildor, Adi; Machtei, Eli E; Gabay, Eran; Frankenthal, Shai; Levin, Liran; Suzuki, Marcelo; Coelho, Paulo G; Zigdon-Giladi, Hadar

    2014-10-01

    The primary aim is to evaluate clinical, radiographic, and histologic parameters of novel implants with "three roots" design that were inserted into fresh multirooted extraction sockets. A secondary aim is to compare this new implant to standard root-form dental implants. Immediate implantation of novel or standard design 6 × 6-mm implants was performed bilaterally into multirooted sockets in mandibles of mini-pigs. Twelve weeks later, clinical, radiographic, stability, histomorphometric, and microcomputed tomography (micro-CT) analyses were performed. Survival rates were significantly higher in the test implants compared with control (92.8% versus 33.3%, respectively; P micro-CT analyses demonstrated bone fill in the inner part of the test implants. Moreover, bone-to-implant contact was higher in the test implants (55.50% ± 3.68% versus 42.47% ± 9.89%). Contrary to the clinical, radiographic, and histomorphometric results, resonance frequency analysis measurements were greater in the control group (77.74 ± 3.21 implant stability quotient [ISQ]) compared with the test group (31.09 ± 0.28 ISQ), P = 0.008. The novel design implants resulted in significantly greater survival rate in multirooted extraction sites. Further studies will be required to validate these findings.

  11. Osseointegration of a 3D Printed Stemmed Titanium Dental Implant: A Pilot Study

    OpenAIRE

    James Tedesco; Bryan E. J. Lee; Alex Y. W. Lin; Dakota M. Binkley; Kathleen H. Delaney; Jacek M. Kwiecien; Kathryn Grandfield

    2017-01-01

    In this pilot study, a 3D printed Grade V titanium dental implant with a novel dual-stemmed design was investigated for its biocompatibility in vivo. Both dual-stemmed (n = 12) and conventional stainless steel conical (n = 4) implants were inserted into the tibial metaphysis of New Zealand white rabbits for 3 and 12 weeks and then retrieved with the surrounding bone, fixed, dehydrated, and embedded into epoxy resin. The implants were analyzed using correlative histology, microcomputed tomogra...

  12. A three-dimensional finite element analysis for overdenture attachments supported by teeth and/or mini dental implants.

    Science.gov (United States)

    Fatalla, Abdalbseet A; Song, Ke; Du, Tianfeng; Cao, Yingguang

    2012-12-01

    The aim of this study was to establish the optimum design and attachment combination to support an overdenture with minimal stress and flexing produced in the alveolar bone surrounding any natural teeth and/or mini dental implants. Twelve models were included in the study: the six main models (A, B, C, D, E, and F) were categorized according to the support designs of the overdenture prosthesis, and each model was further subdivided according to the attachment combinations into model 1: with Dalbo elliptic and/or O-ring attachments only and model 2: with flexible acrylic attachments. Vertical loads (35 N) and 17.5 N lateral loads under static conditions were applied to the models to simulate the occlusal forces following the concept of lingualized occlusion. All conditions were created using a finite element software program. Maximum von Mises stress at the level of the attachments and at the bone support foundation interfaces were compared in all 12 models. The flexing of the mandible and the attachments were also compared qualitatively. Stress on these models was analyzed after the given loading condition. The results showed that the model with three freestanding mini dental implants and flexible acrylic attachments showed the lowest von Mises stress and flexing, while the models with four freestanding mini dental implants and O-ring attachments showed the highest von Mises stress. Three freestanding mini dental implants with flexible acrylic attachment systems supporting an overdenture were better choices than four mini dental implants with O-ring attachment systems, which showed the maximum flexing and stress values in this qualitative comparison. © 2012 by the American College of Prosthodontists.

  13. Analysis of risk factors for cluster behavior of dental implant failures.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-08-01

    Some studies indicated that implant failures are commonly concentrated in few patients. To identify and analyze cluster behavior of dental implant failures among subjects of a retrospective study. This retrospective study included patients receiving at least three implants only. Patients presenting at least three implant failures were classified as presenting a cluster behavior. Univariate and multivariate logistic regression models and generalized estimating equations analysis evaluated the effect of explanatory variables on the cluster behavior. There were 1406 patients with three or more implants (8337 implants, 592 failures). Sixty-seven (4.77%) patients presented cluster behavior, with 56.8% of all implant failures. The intake of antidepressants and bruxism were identified as potential negative factors exerting a statistically significant influence on a cluster behavior at the patient-level. The negative factors at the implant-level were turned implants, short implants, poor bone quality, age of the patient, the intake of medicaments to reduce the acid gastric production, smoking, and bruxism. A cluster pattern among patients with implant failure is highly probable. Factors of interest as predictors for implant failures could be a number of systemic and local factors, although a direct causal relationship cannot be ascertained. © 2017 Wiley Periodicals, Inc.

  14. Clinical evaluation of a novel dental implant system as single implants under immediate loading conditions - 4-month post-loading results from a multicentre randomised controlled trial.

    Science.gov (United States)

    Esposito, Marco; Trullenque-Eriksson, Anna; Blasone, Rodolfo; Malaguti, Giuliano; Gaffuri, Cristiano; Caneva, Marco; Minciarelli, Armando; Luongo, Giuseppe

    To evaluate the safety and clinical effectiveness of a novel dental implant system (GENESIS Implant System, Keystone Dental, Massachusetts, USA) using another dental implant system by the same manufacturer as a control (PRIMA Implant System, Keystone Dental). A total of 53 patients requiring at least two single crowns had their sites randomised according to a split-mouth design to receive both implant systems at six centres. If implants could be placed with a torque superior to 40 Ncm they were to be loaded immediately with provisional crowns, otherwise after 3 months of submerged healing. Provisional crowns were replaced by definitive crowns 4 months after initial loading, when the follow-up period for the initial part of this study was completed. Outcome measures were crown/implant failures, complications, pink esthetic score (PES), peri-implant marginal bone level changes, plaque score, marginal bleeding, patients and preference of the clinician. In total 53 PRIMA and 53 GENESIS implants were placed. Three patients dropped out but all of the remaining patients were followed up to 4-months post-loading. No PRIMA implant failed whereas four GENESIS implants failed. Only two complications were reported for PRIMA implants. There were no statistically significant differences for crown/implant failures (difference in proportions = 0.080; P (McNemar test) = 0.125) and complications (difference in proportions = -0.04; P (McNemar test) = 0.500) between the implant systems. There were no differences at 4-months post-loading for plaque (difference = -0.54, 95% CI: -3.01 to 1.93; P (Paired t-test) = 0.660), marginal bleeding (difference = -3.8, 95% CI: -7.63 to 0.019; P (Paired t-test) = 0.051), PES (difference = 0.47, 95% CI: -0.56 to 1.50; P (Paired t-test) = 0.365) and marginal bone level changes (difference in mm = -0.04, 95% CI: -0.33 to 0.26; P (Paired t-test) = 0.795). The majority of the patients (46) had no

  15. Long-term Survival of Straumann Dental Implants with TPS Surfaces: A Retrospective Study with a Follow-up of 12 to 23 Years.

    Science.gov (United States)

    Becker, Stephan T; Beck-Broichsitter, Benedicta E; Rossmann, Christian M; Behrens, Eleonore; Jochens, Arne; Wiltfang, Jörg

    2016-06-01

    The aim of this study was to evaluate the long-term dental implant survival rates of Straumann dental implants in a university hospital environment over 12 to 23 years. A total of 388 Straumann dental implants with titanium-sprayed surfaces (TPS) were inserted in 92 patients between 1988 and 1999 in the Department of Oral and Maxillofacial Surgery of the University Hospital Schleswig-Holstein in Kiel, and they were reevaluated with standardized clinical and radiological exams. Kaplan-Meier analyses were performed for individual factors. Cox proportional hazard regression analysis was used to detect the factors influencing long-term implant failure. The long-term implant survival rate was 88.03% after an observation time of 12.2 to 23.5 years. Cox regression revealed statistically significant influences of the International Team for Implantology (ITI) implantation type (p = .00354) and tobacco smoking (p = .01264) on implant failure. A proportion 82.8% of the patients with implant losses had a medical history of periodontitis. Peri-implantitis was diagnosed in 9.7% of the remaining implants in the long-term survey. This study emphasized the long-term rehabilitation capabilities of Straumann dental implants in complex cases. The survival rates after several years constitute important information for patients, as well as for clinicians, in deciding about different concepts of tooth replacement. Patient-related and technical factors - determined before implant placement - could help to predict the risk of implant loss. © 2015 Wiley Periodicals, Inc.

  16. Controlled release of metronidazole from composite poly-ε-caprolactone/alginate (PCL/alginate) rings for dental implants.

    Science.gov (United States)

    Lan, Shih-Feng; Kehinde, Timilehin; Zhang, Xiangming; Khajotia, Sharukh; Schmidtke, David W; Starly, Binil

    2013-06-01

    Dental implants provide support for dental crowns and bridges by serving as abutments for the replacement of missing teeth. To prevent bacterial accumulation and growth at the site of implantation, solutions such as systemic antibiotics and localized delivery of bactericidal agents are often employed. The objective of this study was to demonstrate a novel method of controlled localized delivery of antibacterial agents to an implant site using a biodegradable custom fabricated ring. The study involved incorporating a model antibacterial agent (metronidazole) into custom designed poly-ε-caprolactone/alginate (PCL/alginate) composite rings to produce the intended controlled release profile. The rings can be designed to fit around the body of any root form dental implants of various diameters, shapes and sizes. In vitro release studies indicate that pure (100%) alginate rings exhibited an expected burst release of metronidazole in the first few hours, whereas Alginate/PCL composite rings produced a medium burst release followed by a sustained release for a period greater than 4 weeks. By varying the PCL/alginate weight ratios, we have shown that we can control the amount of antibacterial agents released to provide the minimal inhibitory concentration (MIC) needed for adequate protection. The fabricated composite rings have achieved a 50% antibacterial agent release profile over the first 48 h and the remaining amount slowly released over the remainder of the study period. The PCL/alginate agent release characteristic fits the Ritger-Peppas model indicating a diffusion-based mechanism during the 30-day study period. The developed system demonstrates a controllable drug release profile and the potential for the ring to inhibit bacterial biofilm growth for the prevention of diseases such as peri-implantitis resulting from bacterial infection at the implant site. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  17. Dental implant treatment following trauma: An investigation into the failure to complete Accident Compensation Corporation funded care.

    Science.gov (United States)

    Kennedy, R; Murray, C; Leichter, J

    2016-03-01

    Among other restorative strategies, the Accident Compensation Corporation (ACC) provides benefits for dental implant treatment to replace teeth lost as a result of trauma. While ACC has funded over 15,000 dental implants since 2002, the outcomes of this treatment and patient perceptions of this treatment have not been investigated. The aim of this study was to investigate the perceptions of the dental implant treatment outcomes and reasons for failure to complete restorative treatment in patients who had undergone trauma-related implant surgery funded by ACC between February 2006 and September 2009, but had not completed the prosthetic component of the treatment. A randomly selected sample of 399 patients, who had undergone dental implant surgery but not completed the crown restoration, was identified from the ACC database. These individuals were contacted by mail for expressions of interest and 181 clients were interviewed by telephone. Responses to open-ended questions were entered into an Excel spreadsheet and analysed using a general inductive technique. A common emergent theme was the high level of satisfaction expressed by participants with the implant process, however just under half of those responding felt they had been pushed into having implants and were given the impression that this was the only treatment ACC paid for. The cost of the prosthetic phase of the treatment and surgical complications were identified as the primary reasons why participants failed to complete the restorative phase of treatment, after completing the surgical phase. The results highlighted the need to better inform patients of their treatment options and to allow time for them to process this information before progressing with care. A patient decision tool may help to give greater ownership of the treatment options. Newly implemented protocols to assist dentists to better assess treatment needs may also assist in achieving improvements in perceived treatment outcomes for

  18. Importancia del tratamiento ortodóncico en la efectividad de los implantes dentales

    Directory of Open Access Journals (Sweden)

    Isabel Cristina Díaz Acosta

    Full Text Available Los implantes osteointegrados permite recuperar de forma fija y cómoda todas las funciones del diente perdido. El objetivo de esta presentación es demostrar los beneficios de realizar tratamientos ortodóncico previos a la colocación de implantes dentales en pacientes edentes. Un paciente de 21 años acudió a consulta de implantología en la Clínica Estomatológica Provincial Docente “Dr. Ismael Clark y Mascaró” de Camagüey, por ausencia de incisivos central y lateral superior derecho (11 y 12. Se valoró por el equipo multidisciplinario, el cual planteó cerrar el espacio de la brecha edente con aparatología ortodóncica fija y después realizar cirugía de avanzada y la colocación de un implante Leader Nano. La rehabilitación protésica se realizó a los ocho meses. Se demostró la eficacia de la realización de tratamiento ortodóncico previo a la colocación de implantes dentales así como el restablecimiento del estado estético y psicológico del paciente.

  19. Scientific Fundamentals and Technological Development of Novel Biocompatible/Corrosion Resistant Ultrananocrystalline Diamond (UNCD) Coating Enabling Next Generation Superior Metal-Based Dental Implants

    Science.gov (United States)

    Kang, Karam

    Current Ti-based dental implants exhibit failure (2-10%), due to various mechanisms, including chemical corrosion of the surface of the TiO2 naturally covered Ti-based implants. This thesis focused on developing a unique biocompatible/bio-inert/corrosion resistant/low cost Ultrananocrystalline Diamond (UNCD) coating (with 3-5 nm grain size) for encapsulation of Tibased micro-implants to potentially eliminate the corrosion/mechanical induced failure of current commercial Ti-based dental implants. Microwave Plasma Chemical Vapor Deposition (MPCVD) and Hot Filament Chemical Vapor Deposition (HFCVD) processes were used to grow UNCD coatings. The surface topography and chemistry of UNCD coatings were characterized using scanning electron microscopy (SEM), Raman, and X-ray photoelectron spectroscopies (XPS) respectively. In conclusion, this thesis contributed to establish the optimal conditions to grow UNCD coatings on the complex 3-D geometry of Ti-based micro-implants, with geometry similar to real implants, relevant to developing UNCD-coated Ti-based dental implants with superior mechanical/chemical performance than current Ti-based implants.

  20. Electrochemical coating of dental implants with anodic porous titania for enhanced osteointegration

    Directory of Open Access Journals (Sweden)

    Amirreza Shayganpour

    2015-11-01

    Full Text Available Clinical long-term osteointegration of titanium-based biomedical devices is the main goal for both dental and orthopedical implants. Both the surface morphology and the possible functionalization of the implant surface are important points. In the last decade, following the success of nanostructured anodic porous alumina, anodic porous titania has also attracted the interest of academic researchers. This material, investigated mainly for its photocatalytic properties and for applications in solar cells, is usually obtained from the anodization of ultrapure titanium. We anodized dental implants made of commercial grade titanium under different experimental conditions and characterized the resulting surface morphology with scanning electron microscopy equipped with an energy dispersive spectrometer. The appearance of nanopores on these implants confirm that anodic porous titania can be obtained not only on ultrapure and flat titanium but also as a conformal coating on curved surfaces of real objects made of industrial titanium alloys. Raman spectroscopy showed that the titania phase obtained is anatase. Furthermore, it was demonstrated that by carrying out the anodization in the presence of electrolyte additives such as magnesium, these can be incorporated into the porous coating. The proposed method for the surface nanostructuring of biomedical implants should allow for integration of conventional microscale treatments such as sandblasting with additive nanoscale patterning. Additional advantages are provided by this material when considering the possible loading of bioactive drugs in the porous cavities.

  1. Induced hemocompatibility and bone formation as biological scaffold for cell therapy implant

    Directory of Open Access Journals (Sweden)

    Keng-Liang Ou

    2016-06-01

    Full Text Available Although stem cells can become almost any type of specialized cell in the human body and may have the potential to generate replacement cells for tissues and organs, the transplantation of these cells are hindered by immune rejection and teratoma formation. However, scientists have found a promising solution for these problems-they have discovered the ability to isolate stem cells from a patient’s umbilical cord blood or bone marrow. Even more recently, small stem cells, such as spore-like stem cells, Blastomere-Like Stem Cells (BLSCs, and Very-Small Embryonic-Like stem cells (VSELs isolated directly from the peripheral blood have beeninvestigated as a novel approach to stem cell therapy as they can be isolated directly from the peripheral blood. A newly-discovered population of multipotent stem cells in this class has been dubbed StemBios (SB cells. The potential therapeutic uses of such stem cells have been explored in many ways, one of which includes dental remodeling and construction. Using adult stem cells, scientists have engineered and cultivated teeth in mice that may one day be used for human implantation.It follows that such regeneration may be possible, to a certain degree, in human patients as well. This idea leads to the present study on the effect of SB cell therapy on early osseointegrationof dental implants. Titanium (Ti dental implants have been proven to be a reliable and predictable treatment for restoration of edentulous regions. The osseointegration process can be described in two stages: primary stability (mechanical stability and secondary stability (biological stability. The mechanical stabilization of the implant reflects the interaction between the bone density and the features of the implant designs and can be determined after implant insertion. Alternatively,the biological stabilization of the implant is a physiologic healing process. It is couple to the biological interaction between the external surface of the

  2. Application of digital diagnostic impression, virtual planning, and computer-guided implant surgery for a CAD/CAM-fabricated, implant-supported fixed dental prosthesis: a clinical report.

    Science.gov (United States)

    Stapleton, Brandon M; Lin, Wei-Shao; Ntounis, Athanasios; Harris, Bryan T; Morton, Dean

    2014-09-01

    This clinical report demonstrated the use of an implant-supported fixed dental prosthesis fabricated with a contemporary digital approach. The digital diagnostic data acquisition was completed with a digital diagnostic impression with an intraoral scanner and cone-beam computed tomography with a prefabricated universal radiographic template to design a virtual prosthetically driven implant surgical plan. A surgical template fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) was used to perform computer-guided implant surgery. The definitive digital data were then used to design the definitive CAD/CAM-fabricated fixed dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Increased crown-to-implant ratio may not be a risk factor for dental implant failure under appropriate plaque control.

    Science.gov (United States)

    Okada, Shinsuke; Koretake, Katsunori; Miyamoto, Yasunari; Oue, Hiroshi; Akagawa, Yasumasa

    2013-01-01

    The aim of this study was to evaluate whether increased crown-to-implant (C/I) ratio influences implant stability or not under proper healthy control of peri-implant mucosa. The hypothesis of this study is that implant stability can be maintained despite High C/I, under appropriate plaque control. Five male Beagle-Labrador hybrid dogs (2 years old) were used. Their bilateral mandibular premolar extraction was performed. After allowing 12 weeks for bone healing, 3 types of vertical marginal bone loss were simultaneously prepared randomly. Then, 30 titanium implants were placed in the edentulous areas and defined as High C/I, Mid C/I and Low C/I groups. This time point was designated as the baseline (0 Week). Twelve weeks after implant placement, metal superstructures were cemented to the implants and an occlusal plate was set at the opposite side. At the same time, Calcein green was injected for remodeling evaluation. Implants were loaded by feeding the dogs a hard pellet diet. Tooth brushing was performed 5 days per week during the study to maintain healthy peri-implant mucosa. Twenty-four weeks following implant placement, the interface structure was evaluated clinically, radiologically, and histologically. Implant stability quotient (ISQ) increased with time in all 3 groups, without any significant correlation with the C/I value (p >0.05). Moreover, mean marginal bone loss adjacent around implants in all 3 groups ranged between 0.11 and 0.19 mm, with no significant difference (p >0.05). Many fluorescence-labeled bones are shown in the High C/I group. It is considered that high remodeling activity prevent marginal bone loss in the High C/I group and this may provide favorable implant stability under proper plaque control. These findings suggest that increased C/I may not be a risk factor for implant failure if the peri-implant mucosa is kept healthy, as was the case in this animal model.

  4. Increased crown-to-implant ratio may not be a risk factor for dental implant failure under appropriate plaque control.

    Directory of Open Access Journals (Sweden)

    Shinsuke Okada

    Full Text Available OBJECTIVE: The aim of this study was to evaluate whether increased crown-to-implant (C/I ratio influences implant stability or not under proper healthy control of peri-implant mucosa. The hypothesis of this study is that implant stability can be maintained despite High C/I, under appropriate plaque control. MATERIALS AND METHODS: Five male Beagle-Labrador hybrid dogs (2 years old were used. Their bilateral mandibular premolar extraction was performed. After allowing 12 weeks for bone healing, 3 types of vertical marginal bone loss were simultaneously prepared randomly. Then, 30 titanium implants were placed in the edentulous areas and defined as High C/I, Mid C/I and Low C/I groups. This time point was designated as the baseline (0 Week. Twelve weeks after implant placement, metal superstructures were cemented to the implants and an occlusal plate was set at the opposite side. At the same time, Calcein green was injected for remodeling evaluation. Implants were loaded by feeding the dogs a hard pellet diet. Tooth brushing was performed 5 days per week during the study to maintain healthy peri-implant mucosa. Twenty-four weeks following implant placement, the interface structure was evaluated clinically, radiologically, and histologically. RESULT: Implant stability quotient (ISQ increased with time in all 3 groups, without any significant correlation with the C/I value (p >0.05. Moreover, mean marginal bone loss adjacent around implants in all 3 groups ranged between 0.11 and 0.19 mm, with no significant difference (p >0.05. Many fluorescence-labeled bones are shown in the High C/I group. It is considered that high remodeling activity prevent marginal bone loss in the High C/I group and this may provide favorable implant stability under proper plaque control. CONCLUSION: These findings suggest that increased C/I may not be a risk factor for implant failure if the peri-implant mucosa is kept healthy, as was the case in this animal model.

  5. Teaching mandibular implant-Supported overdentures in dental schools in North America - a survey.

    Science.gov (United States)

    Ben-Gal, G; Ziv, Y; Weiss, E I; Zabrovsky, A

    2017-05-01

    Mandibular two-implant overdentures are considered the minimum standard of care for edentulous patients and provide an excellent performance, as well as satisfaction to the patients. Dental schools are required to promote the teaching of current treatment options in order to enable students to master state-of-the-art procedures. The purpose of this study was to examine how the theoretical and practical aspects of mandibular two-implant overdentures are taught in dental schools in North America. Data were collected via an online questionnaire that included questions regarding the theoretical and clinical courses, surgical procedure and imaging method. Of 75 schools, 36 responded to the survey. Almost all the schools teach the subject theoretically, but it is not mandatory for students to perform in most of the schools. Only a minority (23%) of the mandibular dentures made by students are implant-supported. Almost all of the schools (94%) use two implants to support overdentures, and Locator abutment is used almost exclusively. The prevalent imaging for the surgical procedure is CT scans, although 30% of the schools use panoramic radiograph. None of the schools loads the implants immediately after surgery. Some clear trends are apparent in the current survey: the use of two implants, no use of bar connectors and delayed loading of the implants. It is likely that graduates will not have sufficient clinical skills and will need continuing education to be familiar with the required procedures, both surgical and prosthetic. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Unconstrained tripolar hip implants: effect on hip stability.

    Science.gov (United States)

    Guyen, Olivier; Chen, Qing Shan; Bejui-Hugues, Jacques; Berry, Daniel J; An, Kai-Nan

    2007-02-01

    Tripolar implants were developed to treat unstable total hip arthroplasties. However, there is limited confirmation that they achieve this purpose despite their increasing use. Because they have a larger effective head size, these implants are expected to increase range of motion to impingement and improve stability in situations at risk for impingement compared with conventional implants. We assessed the range of motion to impingement using a tripolar implant mounted to an automated hip simulator using 22.2-mm and 28-mm femoral head sizes. The 22 and 28-mm tripolar implants provided increases of 30.5 degrees in flexion, 15.4 degrees in adduction, and 22.4 degrees in external rotation compared with the conventional 22.2-mm femoral head diameter implant. At the critical position of 90 degrees hip flexion, there was an increase of 45.2 degrees in internal rotation. At 0 degrees and 30 degrees external rotation, extension increases were 18.8 degrees and 7.8 degrees, respectively. Bony impingement was the limiting factor. Tripolar implants increased the arc of motion before impingement in positions at risk for dislocation and are expected to provide greater stability.

  7. A dental implant-based registration method for measuring mandibular kinematics using cone beam computed tomography-based fluoroscopy.

    Science.gov (United States)

    Lin, Cheng-Chung; Chen, Chien-Chih; Chen, Yunn-Jy; Lu, Tung-Wu; Hong, Shih-Wun

    2014-01-01

    This study aimed to develop and evaluate experimentally an implant-based registration method for measuring three-dimensional (3D) kinematics of the mandible and dental implants in the mandible based on dental cone beam computed tomography (CBCT), modified to include fluoroscopic function. The proposed implant-based registration method was based on the registration of CBCT data of implants/bones with single-plane fluoroscopy images. Seven registration conditions that included one to three implants were evaluated experimentally for their performance in a cadaveric porcine headmodel. The implant-based registration method was shown to have measurement errors (SD) of less than -0.2 (0.3) mm, 1.1 (2.2) mm, and 0.7 degrees (1.3 degrees) for the in-plane translation, out-of-plane translation, and all angular components, respectively, regardless of the number of implants used. The corresponding errors were reduced to less than -0.1 (0.1) mm, -0.3 (1.7) mm, and 0.5 degree (0.4 degree) when three implants were used. An implant-based registration method was developed to measure the 3D kinematics of the mandible/implants. With its high accuracy and reliability, the new method will be useful for measuring the 3D motion of the bones/implants for relevant applications.

  8. Knowledge, aptitudes, and preferences in implant dentistry teaching/training among undergraduate dental students at the University of Barcelona

    Science.gov (United States)

    Berástegui-Jimeno, Esther; Gay-Escoda, Cosme

    2017-01-01

    Background Oral implant rehabilitation should be considered a treatment option for any edentulous patient and Implant Dentistry is currently a discipline taught in the undergraduate formation. The level of knowledge acquired and how the students perceive the quality of training in Implant Dentistry could assess to know if it is necessary to improve the syllabus. Material and Methods A questionnaire was developed with 11 questions: Basic knowledge (7); Perception of training received (2); Ways in which students would receive training (2). To be responded anonymously and voluntarily for undergraduates students in the Faculty of Dentistry (University of Barcelona, Spain). Results One hundred and seven students, 76 third year (Group A) and 31 fourth year (Group B) answered the questionnaire. In Group A, 98.68% of students and in Group B 93.54% believed they were poorly informed; 100% of both groups would prefer to receive more training as part of the degree or as postgraduate training through modular courses imparted by experts (A: 71,05%, B: 70,96%) Training through postgraduate programs or training given by private businesses were the least desirable options (A: 42%, B: 64.51%). Questions about basic knowledge acquired received varying responses, which might indicate a certain level of confusion in this area. Conclusions The undergraduate syllabus must be revised to include sufficient content and training to allow the student to indicate implant-based treatments based on evidence. Students would prefer training to be included in the undergraduate syllabus. Key words:Dental implants, dental students, dental education, dental syllabus, implant dentistry. PMID:28578375

  9. Prosthodontic perspective to all-on-4® concept for dental implants.

    Science.gov (United States)

    Taruna, M; Chittaranjan, B; Sudheer, N; Tella, Suchita; Abusaad, Md

    2014-10-01

    The clinical success and longevity of endosteal dental implants as load bearing abutments are controlled largely by the mechanical setting in which they function. The treatment plan is responsible for the design, number and position of the implants. In biomechanically compromised environment such as poor quality bone, strain to the crestal bone can be reduced by increasing the anterioposterior spread of implants, placement of longer implants and maximizing the number of implants. The All-on-4(®) concept is one such treatment procedure which enlightens us for its use in the completely edentulous patients and which also leaves behind the routine treatment alternative of conventional dentures with successful outcome in the short term, long term and the retrospective studies that have been done in the past. The area of concern for any treatment alternative lies in the success of the prosthesis and its prosthodontic perspective involving the principles of occlusion. This article reviews the All-on-4(®) concept and its prosthodontic aspects.

  10. Displacement of a dental implant into the maxillary sinus after internal sinus floor elevation: report of a case and review of literature.

    Science.gov (United States)

    Ding, Xiaojun; Wang, Qing; Guo, Xuehua; Yu, Youcheng

    2015-01-01

    Dental implant placement in the posterior maxilla may be complicated by implant migration into the maxillary sinus. To report the clinical and radiological characteristics of a patient who experienced dental implant displacement into the maxillary sinus following sinus floor elevation, and to compare our findings with those of other published reports of the displacement of dental implants. Implant placement and maxillary sinus elevation were performed simultaneously. The location of the displaced implant was monitored for 8 years, until the ectopic implant was surgically removed using the lateral window approach. The contributing factors, treatment modality, and clinical outcome for our patient were compared with those of patients reported in the literature. The clinical characteristics of our case were similar to those of patients with displaced implants who were also asymptomatic for long periods. The clinical outcome of our case was consistent with that of patients who underwent similar surgeries. Transnasal endoscopic removal of an ectopic implant may be suitable in cases in which the ectopic implant is accessible. Transoral direct approaches are adequate in most cases in which endoscopic approaches may be confounded. The bony-window transoral technique may allow the removal of large implants.

  11. The efficacy of short (6 mm) dental implants with a novel thread design.

    Science.gov (United States)

    Bechara, Soheil; Nimčenko, Tatjana; Kubilius, Ričardas

    2017-01-01

    To assess efficacy of short (6 mm) implants with a novel macrostructure and thread design placed in a compromised bone situations of edentulous posterior regions of maxilla (3-4 mm of bone height under sinus floor) as compared to results of clinical situations treated with simultaneous maxillary sinus grafting and placement of long (≥10 mm) implants of the same company. Clinical cases of conducted clinical study. Patients with compromised bone height in edentulous posterior regions of maxilla were randomly divided into two groups. Short (6mm length) implant treatment conducted in the test group and simultaneous sinus lift with standard length implant placement treatment in the control group. In general implant stability quotient (ISQ) and marginal bone level (MBL) changes values in both groups were comparable. However, significant negative correlation was found between implant's diameter and MBL changes. Implant's length has little if none impact on initial implant anchorage, especially in greatly compromised residual bone situations. Results have confirmed that implant initial stability mainly depends on implant's macro-design and further its development on implant's micro-design: namely, implant diameter rather than length, tapered shape and improved thread design determines primarily acquired mechanical anchorage, while bioactive surface treatment ensures development of biological stability.

  12. Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: a systematic review

    NARCIS (Netherlands)

    Meursinge Reynders, Reint; Ladu, Luisa; Ronchi, Laura; Di Girolamo, Nicola; de Lange, Jan; Roberts, Nia; Plüddemann, Annette

    2016-01-01

    Most orthodontic mini-implants (OMIs) are inserted between dental roots. The prevalence of contacting these structures is high. Such contacts can cause permanent root damage and implant instability. Increased torque levels during implant insertion (the index test) could be a more accurate and

  13. Life prediction of different commercial dental implants as influence by uncertainties in their fatigue material properties and loading conditions.

    Science.gov (United States)

    Pérez, M A

    2012-12-01

    Probabilistic analyses allow the effect of uncertainty in system parameters to be determined. In the literature, many researchers have investigated static loading effects on dental implants. However, the intrinsic variability and uncertainty of most of the main problem parameters are not accounted for. The objective of this research was to apply a probabilistic computational approach to predict the fatigue life of three different commercial dental implants considering the variability and uncertainty in their fatigue material properties and loading conditions. For one of the commercial dental implants, the influence of its diameter in the fatigue life performance was also studied. This stochastic technique was based on the combination of a probabilistic finite element method (PFEM) and a cumulative damage approach known as B-model. After 6 million of loading cycles, local failure probabilities of 0.3, 0.4 and 0.91 were predicted for the Lifecore, Avinent and GMI implants, respectively (diameter of 3.75mm). The influence of the diameter for the GMI implant was studied and the results predicted a local failure probability of 0.91 and 0.1 for the 3.75mm and 5mm, respectively. In all cases the highest failure probability was located at the upper screw-threads. Therefore, the probabilistic methodology proposed herein may be a useful tool for performing a qualitative comparison between different commercial dental implants. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. Dental implants and improvement of oral health-related quality of life

    Czech Academy of Sciences Publication Activity Database

    Kříž, P.; Seydlová, M.; Dostálová, T.; Valenta, Zdeněk; Chleborád, K.; Zvárová, Jana; Feberová, J.; Hippmann, R.

    2012-01-01

    Roč. 40, Suppl. 1 (2012), s. 65-70 ISSN 0301-5661 R&D Projects: GA MŠk(CZ) 1M06014 Institutional research plan: CEZ:AV0Z10300504 Keywords : dental implant * oral health-related quality of life Subject RIV: FF - HEENT, Dentistry Impact factor: 1.797, year: 2012

  15. Effects of H-implantation energy on the optical stability of implanted usher films under photo-irradiation

    International Nuclear Information System (INIS)

    Awazu, K.; Yasui, H.; Kasamori, M.; Ichikawa, T.; Funada, Y.; Iwaki, M.

    1999-01-01

    A study has been made on the improvement of the optical stability of urushi films under optical irradiation using ion implantation. Ion implantation of hydrogen ions in urushi films was performed with a dose of 10 15 ions/cm 2 at ion energies ranging from 0.2 to 150 keV at room temperature. The photo-irradiation onto the urushi films was carried out at irradiation energies ranging from 40 to 400 MJ/m 2 . H-implantation onto urushi films is useful for improving the optical stability under photo-irradiation when the implantation energy is larger than 60 keV

  16. Clinical evaluation of the stability of implants placed at different supracrestal levels.

    Science.gov (United States)

    Gultekin, B Alper; Sirali, Ali; Gultekin, Pinar; Ersanli, Selim

    2016-01-01

    The aim of this study was to evaluate the stability during healing and before loading of implants placed at two different supracrestal levels according to their collar texture. This retrospective study included patients who received posterior implants with the same macro design. Implants with a machined collar were placed 0.3 mm above the crestal bone (M group), while those with a laser-microtextured collar were placed 1 mm above the crestal bone (L group). All implants healed in a single stage with healing abutments. Implant stability quotient (ISQ) values were determined using resonance frequency analysis immediately after implant placement during surgery and after 1, 4, 8, and 12 weeks after surgery. Other evaluated factors for stability included the implant diameter and length and the site of placement (maxilla or mandible). In total, 103 implants (47 L, 56 M) were evaluated. The median ISQ values at baseline and 1 week after placement were significantly higher for the M group than for the L group (p=0.006 and p=0.031, respectively). There were no differences at the subsequent observation points. The ISQ value was higher for wide-diameter than regular diameter (p=0.001) and mandibular implants than maxillary implants (p=0.001 at 0-8. weeks; p=0.012 at 12 weeks) at all observation points. When diameter data were neglected, the implant length did not influence the ISQ value at all observation points. Our results suggest that submerging implant more inside bone may only influence primary stability. Moreover, the implant diameter and site of placement influence primary and secondary stability before loading, whereas the implant length does not when its diameter is not accounted for.

  17. Implant support for removable partial overdentures: a case report.

    Science.gov (United States)

    Halterman, S M; Rivers, J A; Keith, J D; Nelson, D R

    1999-01-01

    Functional stability and the preservation of remaining alveolar bone are primary, and often elusive, goals when restoring the partially edentulous arch. The incorporation of dental implants for the partial support of removable prostheses offers a practical adjunct in the fulfillment of these objectives. Planning for complex courses of treatment that include dental implants requires close coordination between the surgeon and the restorative dentist. Decisions that deal with type, location, size, number of implant fixtures, and design of the prosthesis are critical. All of these areas must be discussed and established as acceptable to the patient and each clinician before the initiation of treatment. In this report, we present a course of patient treatment in which a removable partial denture is supported by natural remaining teeth in conjunction with osseointegrated implants.

  18. Stability of percutaneously implanted markers for lung stereotactic radiotherapy

    DEFF Research Database (Denmark)

    Persson, Gitte Bjørnsen Fredberg; Josipovic, Mirjana; Von Der Recke, Peter

    2013-01-01

    The purpose of this study was to evaluate the stability of complex markers implanted into lung tumors throughout a course of stereotactic body radiotherapy (SBRT). Fifteen patients referred for lung SBRT were prospectively included. Radio-opaque markers were implanted percutaneously, guided...... mm in one or more registrations throughout the SBRT course. This is the first study to evaluate stability of complex markers implanted percutaneously into lung tumors for image guidance in SBRT. We conclude that the observed stability of marker position within the tumor indicates that complex markers...... can be used as surrogates for tumor position during a short course of SBRT as long as the uncertainties related to their position within the tumor are incorporated into the planning target volume....

  19. Gene expression of inflammation and bone healing in peri-implant crevicular fluid after placement and loading of dental implants. A kinetic clinical pilot study using quantitative real-time PCR.

    Science.gov (United States)

    Slotte, Christer; Lennerås, Maria; Göthberg, Catharina; Suska, Felicia; Zoric, Neven; Thomsen, Peter; Nannmark, Ulf

    2012-10-01

    Early detection of healing complications after placement of dental implants is a pressing but elusive goal. This paper proposes a non-invasive diagnostic tool for monitoring healing- and peri-implant disease specific genes, complementary to clinical evaluations. Eighteen partially edentulous patients were recruited to this pilot study. Three Brånemark TiUnite® implants/patient (Nobel Biocare) were placed in a one-stage procedure. Abutments with smooth or rough (TiUnite®) surface were placed. The test group (n = 9) received fixed bridges (immediate loading), whereas the control group (n = 9) implants were loaded 3 months after surgery. In addition to clinical measurements, crevicular fluid was collected using paper strips at the implant abutments 2, 14, 28, and 90 days postoperative. mRNA was extracted, purified, and converted to cDNA. Quantitative PCR assays for IL-1β, TNF-α, Osteocalcin (OC), Alkaline Phosphatase (ALP), Cathepsin K, Tartrate Resistant Acid Phosphatase, and 18S ribosomal RNA were designed and validated. Relative gene expression levels were calculated. One implant was lost in the control group and three in the test group. In one test patient, one implant showed lowered stability after 2 to 4 weeks and was unloaded. Later implant stability improved which allowed for loading after 3 to 4 months. TNF-α and ALP most commonly showed correlation with clinical parameters followed by IL-1β and OC. The strongest correlation was found for TNF-α with clinical complications at 2 and 14 days (p = .01/r = -048, and p = .0004/r = -0.56, respectively; test and control groups together). In some cases, gene expression predicted clinical complications (TNF-α, ALP, CK). This study is based on samples from few individuals; still, some genes showed correlation with clinical findings. Further studies are needed to refine and optimize the sampling process, to find the appropriate panel, and to validate gene expression for monitoring implant healing. © 2010 Wiley

  20. Biomechanical evaluation of one-piece and two-piece small-diameter dental implants: In-vitro experimental and three-dimensional finite element analyses.

    Science.gov (United States)

    Wu, Aaron Yu-Jen; Hsu, Jui-Ting; Chee, Winston; Lin, Yun-Te; Fuh, Lih-Jyh; Huang, Heng-Li

    2016-09-01

    Small-diameter dental implants are associated with a higher risk of implant failure. This study used both three-dimensional finite-element (FE) simulations and in-vitro experimental tests to analyze the stresses and strains in both the implant and the surrounding bone when using one-piece (NobelDirect) and two-piece (NobelReplace) small-diameter implants, with the aim of understanding the underlying biomechanical mechanisms. Six experimental artificial jawbone models and two FE models were prepared for one-piece and two-piece 3.5-mm diameter implants. Rosette strain gauges were used for in-vitro tests, with peak values of the principal bone strain recorded with a data acquisition system. Implant stability as quantified by Periotest values (PTV) were also recorded for both types of implants. Experimental data were analyzed statistically using Wilcoxon's rank-sum test. In FE simulations, the peak value and distribution of von-Mises stresses in the implant and bone were selected for evaluation. In in-vitro tests, the peak bone strain was 42% lower for two-piece implants than for one-piece implants. The PTV was slightly lower for one-piece implants (PTV = -6) than for two-piece implants (PTV = -5). In FE simulations, the stresses in the bone and implant were about 23% higher and 12% lower, respectively, for one-piece implants than those for two-piece implants. Due to the higher peri-implant bone stresses and strains, one-piece implants (NobelDirect) might be not suitable for use as small-diameter implants. Copyright © 2016. Published by Elsevier B.V.

  1. Influence of the Diameter of Dental Implants Replacing Single Molars: 3- to 6-Year Follow-Up.

    Science.gov (United States)

    Mendonça, Jose Alfredo; Senna, Plinio Mendes; Francischone, Carlos Eduardo; Francischone Junior, Carlos Eduardo; Sotto-Maior, Bruno Salles

    The aim of this study was to evaluate the influence of the implant diameter on marginal bone remodeling around dental implants replacing single molars after a follow-up period of 3 to 6 years. Patients who received dental implants with an external hexagon platform in healed sites to support a single metal-ceramic crown in the molar region were recalled to the office. The implantation sites and implant length information were recorded, and the implants were divided according to the implant diameter: regular (RP) or wide (WP). Each implant was assessed by digital periapical radiography, using a sensor holder for the paralleling technique. The marginal bone remodeling was determined as the distance from the implant platform to the first bone-to-implant contact, and the known implant length was used to calibrate the images in the computer software. The follow-up measurements were compared with those obtained from the radiograph taken at the time of prosthetic loading to determine the late bone remodeling. The independent t test was used to compare data. A total of 67 implants from 46 patients were evaluated with a mean follow-up period of 4.5 ± 1.0 years. The RP group comprised 36 implants from 29 patients (mean age: 58.3 ± 10.6 years), while 31 implants from 17 patients (mean age: 56.9 ± 11.5 years) were included in the WP group. The RP group presented lower survival rates (86.1%) than the WP group (100.0%). Similar marginal bone loss (P implants exhibited lower incidence failures, the bone levels were similar after the prosthetic loading around regular- and wide-diameter implants supporting single molar crowns.

  2. Hypoxia-Inducible Factor-1α: A Potential Factor for the Enhancement of Osseointegration between Dental Implants and Tissue-Engineered Bone

    Directory of Open Access Journals (Sweden)

    Duohong Zou

    2011-07-01

    Full Text Available Introduction: Tissue-engineered bones are widely utilized to protect healthy tissue, reduce pain, and increase the success rate of dental implants. one of the most challenging obstacles lies in obtaining effective os-seointegration between dental implants and tissue-engineered structures. Deficiencies in vascularization, osteogenic factors, oxygen, and other nutrients inside the tissue-engineered bone during the early stages following implantation all inhibit effective osseointe-gration. Oxygen is required for aerobic metabolism in bone and blood vessel tissues, but oxygen levels inside tissue-engineered bone are not suf-ficient for cell proliferation. HIF-1α is a pivotal regulator of hypoxic and ischemic vascular responses, driving transcriptional activation of hundreds of genes involved in vascular reactivity, angiogenesis, arteriogenesis, and osteogenesis.The hypothesis: Hypoxia-Inducible Factor-1α seems a potential factor for the enhancement of osseointegration between dental implants and tissue-engineered bone.Evaluation of the hypothesis: Enhancement of HIF-1α protein expression is recognized as the most promising approach for angiogenesis, because it can induce multiple angiogenic targets in a coordinated manner. Therefore, it will be a novel potential therapeutic methods targeting HIF-1α expression to enhance osseointegration be-tween dental implants and tissue-engineered bone.

  3. The impact of glucocorticosteroids administered for systemic diseases on the osseointegration and survival of dental implants placed without bone grafting-A retrospective study in 31 patients.

    Science.gov (United States)

    Petsinis, Vassilis; Kamperos, Georgios; Alexandridi, Foteini; Alexandridis, Konstantinos

    2017-08-01

    To evaluate the impact of glucocorticosteroids, administered for the treatment of systemic diseases, on the osseointegration and survival of dental implants placed without bone grafting. A retrospective study was conducted in search of patients treated with dental implants while receiving glucocorticosteroid therapy for various systemic diseases. In these cases, a conventional two-stage surgical protocol was used, without bone regeneration procedures. The osseointegration was clinically and radiographically tested at the uncovering of the implants. The follow-up after loading was set at a minimum of 3 years. A total of 31 patients were included in the study. Of the 105 dental implants placed, 104 were osseointegrated (99%). No bone absorption was radiographically noted at the uncovering of the osseointegrated implants. All of the osseointegrated implants were successfully loaded for the prosthetic restoration. The mean follow-up period after loading was 71 months, with an implant survival rate of 99%. Glucocorticosteroid intake for systemic diseases does not have a significant impact on the osseointegration and the 3-year survival of dental implants placed with a conventional two-stage surgical protocol and without bone grafting. Therefore, it should not be considered a contraindication for dental implant placement. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  4. Systemic conditions and treatments as risk for therapy with dental implants

    International Nuclear Information System (INIS)

    Arguedas Vega, Natalia; Alfaro Mayorga, Erika

    2013-01-01

    The possible risks for osseointegration are described in patients with specific systemic conditions, medical treatment such as radiation, cardiovascular diseases, HIV and smoking habit. The principal complications for osseointegration of diseases and systemic treatments are exposed. The review and search of the available literature are realized in databases. The scientific literature obtained from human studies has reported the survival of patients with dental implants. The implants are placed in patients with at least one of the conditions studied. The risks of the surgical procedures required for the placement of implants are analyzed in systemically compromised patients. Comparisons of patients with and without systemic conditions in controlled form have remained without analyzing. The level of evidence of absolute and relative contraindications has been low for the therapy with implants in patients with systemic diseases. The revised information is detailed according the systemic conditions, and each of them are evaluated separately [es

  5. Impact of heavy smoking on the clinical, microbiological and immunological parameters of patients with dental implants: a prospective cross-sectional study.

    Science.gov (United States)

    Ata-Ali, Javier; Flichy-Fernández, Antonio Juan; Alegre-Domingo, Teresa; Ata-Ali, Fadi; Peñarrocha-Diago, Miguel

    2016-11-01

    The aim of the present study was to investigate how heavy smoking influences the clinical, microbiological, and host-response characteristics in peri-implant sulcus fluid of patients with healthy dental implants. A total of 29 individuals with 74 dental implants were included in the present study; 20 implants were in heavy smokers and 54 were in non-smokers. The modified gingival index, modified plaque index, and probing pocket depth were evaluated. Periodontopathogenic bacteria Tannerella forsythia, Treponema denticola, and Porphyromonas gingivalis were evaluated, together with the total bacterial load. Peri-implant sulcus fluid samples were analyzed for the quantification of interleukin-8, interleukin-1β, interleukin-6, interleukin-10, and tumor necrosis factor-α. No significant differences in the clinical parameters evaluated were found between the groups, although smokers had poorer peri-implant parameters. Among the smokers, subgingival microbiota was composed of a greater number of periodontal pathogens; these differences were not statistically significant. Smokers showed a greater expression of interleukin-1β, interleukin-6, interleukin-10, and tumor necrosis factor-α, but interleukin-8 was slightly higher among non-smokers, but not significantly. Although smokers presented deeper probing depths, bleeding on probing, and peri-implant microbiota composed of a greater number of periodontal pathogens than in non-smoking patients, these data did not show significant differences. In the present study, and in relation to the samples analyzed, smoking alone did not influence the immunological and microbiological parameters in dental implants with healthy peri-implant tissues. Further studies with larger samples are required to better evaluate the influence of smoking on dental implants. © 2015 Wiley Publishing Asia Pty Ltd.

  6. Surface characterization of titanium based dental implants; Caracterizacao de implantes odontologicos a base de titanio

    Energy Technology Data Exchange (ETDEWEB)

    Castilho, Guilherme Augusto Alcaraz

    2006-07-01

    Dental implantology uses metallic devices made of commercially pure titanium in order to replace lost teeth. Titanium presents favorable characteristics as bio material and modern implants are capable of integrate, witch is the union between bone and implant without fibrous tissue development. Three of the major Brazilian implant manufacturers were chosen to join the study. A foreign manufacturer participated as standard. The manufacturers had three specimens of each implant with two different surface finishing, as machined and porous, submitted to analysis. Surface chemical composition and implant morphology were analyzed by X-ray photoelectron spectroscopy (XP S), scanning electron microscopy (SEM) and microprobe. Implant surface is mainly composed of titanium, oxygen and carbon. Few contaminants commonly present on implant surface were found on samples. Superficial oxide layer is basically composed of titanium dioxide (TiO{sub 2}), another oxides as Ti O and Ti{sub 2}O{sub 3} were also found in small amount. Carbon on implant surface was attributed to manufacturing process. Nitrogen, Phosphorous and Silicon appeared in smaller concentration on surface. There was no surface discrepancy among foreign and Brazilian made implants. SEM images were made on different magnification, 35 X to 3500 X, and showed similarity among as machined implants. Porous surface finishing implants presented distinct morphology. This result was attributed to differences on manufacturing process. Implant bioactivity was accessed through immersion on simulated body solution (SBF) in order to verify formation of an hydroxyapatite (HA) layer on surface. Samples were divided on three groups according to immersion time: G1 (7 days), G2 (14 days), G3 (21 days), and deep in SBF solution at 37 deg C. After being removed from solution, XPS analyses were made and then implants have been submitted to microprobe analysis. XPS showed some components of SBF solution on sample surface but microprobe

  7. CLINICAL EVALUATION OF THE STABILITY OF IMPLANTS PLACED AT DIFFERENT SUPRACRESTAL LEVELS

    Directory of Open Access Journals (Sweden)

    B. Alper GÜLTEKIN

    2016-10-01

    Full Text Available Purpose: The aim of this study was to evaluate the stability during healing and before loading of implants placed at two different supracrestal levels according to their collar texture. Materials and Methods: This retrospective study included patients who received posterior implants with the same macro design. Implants with a machined collar were placed 0.3 mm above the crestal bone (M group, while those with a laser-microtextured collar were placed 1 mm above the crestal bone (L group. All implants healed in a single stage with healing abutments. Implant stability quotient (ISQ values were determined using resonance frequency analysis immediately after implant placement during surgery and after 1, 4, 8, and 12 weeks after surgery. Other evaluated factors for stability included the implant diameter and length and the site of placement (maxilla or mandible. Results: In total, 103 implants (47 L, 56 M were evaluated. The median ISQ values at baseline and 1 week after placement were significantly higher for the M group than for the L group (p=0.006 and p=0.031, respectively. There were no differences at the subsequent observation points. The ISQ value was higher for wide-diameter than regular diameter (p=0.001 and mandibular implants than maxillary implants (p=0.001 at 0-8. weeks; p=0.012 at 12 weeks at all observation points. When diameter data were neglected, the implant length did not influence the ISQ value at all observation points. Conclusion: Our results suggest that submerging implant more inside bone may only influence primary stability. Moreover, the implant diameter and site of placement influence primary and secondary stability before loading, whereas the implant length does not when its diameter is not accounted for.

  8. Satisfaction and Clinical Outcomes Among Patients with Immediately Loaded Mandibular Overdentures Supported by One or Two Dental Implants: Results of a 5-Year Prospective Randomized Clinical Trial.

    Science.gov (United States)

    Kronstrom, Mats; Davis, Ben; Loney, Robert; Gerrow, Jack; Hollender, Lars

    The purpose of this study was to evaluate patient satisfaction and clinical outcomes among subjects with mandibular overdentures supported by one or two immediately placed dental implants 5 years after loading. Thirty-six subjects (16 men and 20 women) received one or two dental implants in the anterior mandible, and all implants were loaded the day of surgery. Subjects were scheduled for follow-up 3-, 6-, and 12 months after implant placement and thereafter annually for 4 more years. Patient satisfaction scores were measured with the Oral Health Impact Profile-EDENT (OHIPEDENT) questionnaire. Seventeen subjects (7 male and 10 female) with a mean age of 59.4 years (range, 44 to 74 years) were available for the 5-year follow-up examination. Nine subjects with 10 failing implants were excluded during the first year and nine subjects were lost to follow-up. No implants failed between the 12- and 60-month follow-up examinations, and the need for denture maintenance was low. Mean peri-implant bone change was 0.92 mm, and the Spearman test failed to show correlation between the insertion torque value and implant stability quotient. Patient satisfaction scores increased significantly when compared with baseline values and continued to be high for both groups, with no significant differences. Ten implants in nine subjects failed early, but no failures were observed after the 12-month examination. No significant differences were found between subjects in the two groups with respect to implant survival rates and peri-implant bone loss, and patient satisfaction scores continued to be high. Although patient satisfaction and implant success were high during the 12- to 60-month period, the results should be interpreted with caution because of the high number of failing implants and patients lost to follow-up. More research is needed to study outcomes of treatment with immediately loaded mandibular implant overdentures.

  9. Evaluation of marginal bone loss of dental implants with internal or external connections and its association with other variables: A systematic review.

    Science.gov (United States)

    de Medeiros, Rodrigo Antonio; Pellizzer, Eduardo Piza; Vechiato Filho, Aljomar José; Dos Santos, Daniela Micheline; da Silva, Emily Vivianne Freitas; Goiato, Marcelo Coelho

    2016-10-01

    Different factors can influence marginal bone loss around dental implants, including the type of internal and external connection between the implant and the abutment. The evidence needed to evaluate these factors is unclear. The purpose of this systematic review was to evaluate marginal bone loss by radiographic analysis around dental implants with internal or external connections. A systematic review was conducted following the criteria defined by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Initially, a population, intervention, comparison, and outcome(s) (PICO) question was defined: does the connection type (internal or external) influence marginal bone loss in patients undergoing implantation? An electronic search of PubMed/MEDLINE and Scopus databases was performed for studies in English language published between January 2000 and December 2014 by 2 independent reviewers, who analyzed the marginal bone loss of dental implants with an internal and/or external connection. From an initial screening yield of 595 references and after considering inclusion and exclusion criteria, 17 articles were selected for this review. Among them, 10 studies compared groups of implants with internal and external connections; 1 study evaluated external connections; and 6 studies analyzed internal connections. A total of 2708 implants were placed in 864 patients. Regarding the connection type, 2347 implants had internal connections, and 361 implants had external connections. Most studies showed lower marginal bone loss values for internal connection implants than for external connection implants. Osseointegrated dental implants with internal connections exhibited lower marginal bone loss than implants with external connections. This finding is mainly the result of the platform switching concept, which is more frequently found in implants with internal connections. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry

  10. Propiedades mecánicas y degradación de implantes dentales de circona estabilizada con itria

    OpenAIRE

    Sevilla Sánchez, Pablo

    2007-01-01

    En la actualidad, el campo de la implantología se encuentra en pleno crecimiento. En pocos años han surgido numerosas empresas fabricantes de implantes dentales y la competencia es cada vez más fuerte. Por esta razón las empresas de implantes dentales apuestan por la innovación y tratan de lanzar al mercado nuevos productos a fin de aumentar su cota de mercado. En odontología la estética es uno de los factores de mayor impacto en el éxito de un tratamiento. Y por ello, cada día...

  11. A 2-year report on maxillary and mandibular fixed partial dentures supported by Astra Tech dental implants. A comparison of 2 implants with different surface textures

    DEFF Research Database (Denmark)

    Karlsson, U; Gotfredsen, K; Olsson, C

    1998-01-01

    In 50 partially edentulous patients, 133 (48 maxillary; 85 mandibular) Astra Tech dental implants of 2 different surface textures (machined; TiO-blasted) were alternately installed, supporting 52 fixed partial dentures (FPDs). Before abutment connection 2 machined implants (1 mandibular; 1...

  12. In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants.

    Science.gov (United States)

    Rack, A; Rack, T; Stiller, M; Riesemeier, H; Zabler, S; Nelson, K

    2010-03-01

    Micro-gap formation at the implant-abutment interface of two-piece dental implants was investigated in vitro using high-resolution radiography in combination with hard X-ray synchrotron radiation. Images were taken with the specimen under different mechanical loads of up to 100 N. The aim of this investigation was to prove the existence of micro-gaps for implants with conical connections as well as to study the mechanical behavior of the mating zone of conical implants during loading. Synchrotron-based radiography in comparison with classical laboratory radiography yields high spatial resolution in combination with high contrast even when exploiting micro-sized features in highly attenuating objects. The first illustration of a micro-gap which was previously indistinguishable by laboratory methods underlines that the complex micro-mechanical behavior of implants requires further in vitro investigations where synchrotron-based micro-imaging is one of the prerequisites.

  13. Nanosurface design of dental implants for improved cell growth and function

    Science.gov (United States)

    Pan, Hsu-An; Hung, Yao-Ching; Chiou, Jin-Chern; Tai, Shih-Ming; Chen, Hsin-Hung; Huang, G. Steven

    2012-08-01

    A strategy was proposed for the topological design of dental implants based on an in vitro survey of optimized nanodot structures. An in vitro survey was performed using nanodot arrays with dot diameters ranging from 10 to 200 nm. MG63 osteoblasts were seeded on nanodot arrays and cultured for 3 days. Cell number, percentage undergoing apoptotic-like cell death, cell adhesion and cytoskeletal organization were evaluated. Nanodots with a diameter of approximately 50 nm enhanced cell number by 44%, minimized apoptotic-like cell death to 2.7%, promoted a 30% increase in microfilament bundles and maximized cell adhesion with a 73% increase in focal adhesions. An enhancement of about 50% in mineralization was observed, determined by von Kossa staining and by Alizarin Red S staining. Therefore, we provide a complete range of nanosurfaces for growing osteoblasts to discriminate their nanoscale environment. Nanodot arrays present an opportunity to positively and negatively modulate cell behavior and maturation. Our results suggest a topological approach which is beneficial for the design of dental implants.

  14. A new spiral dental implant: a tool for oral rehabilitation of difficult cases.

    Science.gov (United States)

    Balan, I; Calcaterra, R; Lauritano, D; Grecchi, E; Carinci, F

    2017-01-01

    Spiral dental implant (SDI) is an implant with a conical internal helix that confers the characteristic of self-drilling, self-tapping, and self-bone condensing. These proprieties offer better control during insertion of SDI giving a high primary stabilization, even in poor quality bone. A shorter diameter of SDI results in reduced drilling during insertion and consequently less trauma and minimal bone loss. To address the research purpose, the investigators designed a retrospective cohort study. The study population was composed of 25 patients, 11 males and 14 females that have been treated by Dr. Balan with 187 SDI positioned in mandible and into maxilla bone. The implants were placed during the years 2013 to 2014 in Dr. Balan clinic. All patients underwent the same surgical protocol. Several variables are investigated: demographic (age and gender), anatomic (upper/lower jaws and tooth site), implant (length and diameter and type) variables, edentulism (partial or total), and comorbid status of health (i.e.: hypothyroidism, parodontitis, hypertension, diabetes, presence of cancer, heart disease, hepatitis and rheumatologic disease). Pearson Chi-Square test was used to investigate variables and p < 0.05 was considered statistically significant. Statistically it has been shown that females have a higher possibility of unsuccessful respect of male, with a "p value" of 0.014. Another important impact factor for success of implant insertion has been represented by concomitants pathologies: cancer represents the most negative high factor risk with a percentage of unsuccessful of 50%, followed by heart disease (15%), and diabetes (3.7%). SDIs are reliable tools for difficult cases of oral rehabilitation. They have a higher success and survival rate, which means stable results over time. No differences were detected among SDI lengths, implant/crown ratio. In addition, the insertion of SDIs in banked bone can be performed without adverse effects. Finally, flapless and

  15. Assessment of the Survival of Dental Implants in Irradiated Jaws Following Treatment of Oral Cancer: A Retrospective Study

    Science.gov (United States)

    Rana, Meenakshi Chauhan; Solanki, Swati; Pujari, Sudarshan C; Shaw, Eisha; Sharma, Swati; Anand, Abhishek; Singh, Harkanwal Preet

    2016-01-01

    Background: In patients undergoing head and neck surgery for various pathologic conditions, implants are one of the best restorative options and are increasing widely used. Therefore, we evaluated the success of dental implants in the irradiated jaws of patients following treatment of oral cancer oral cancer treated patients. Materials and Methods: Data of oral cancer treated patients was collected retrospectively from 2002 to 2008. We took 46 oral cancer treated patients in which implants were placed in irradiated jaws for rehabilitation. Results: It was found that out of 162 dental implants placed, 52 failed. Furthermore, there was no variation in the implant survival rate in between both the jaws. Radiation dose of <50 Gy units also showed significantly increased amount of implant survival rate. Conclusions: Implant survival is multifactorial and depends upon a number of factors like level of radiation exposure in that area, time gap between last radiation doses etc., Further research is required in this field to improve the esthetics and quality of life of cancer treated patients. PMID:27843270

  16. Assessment of the survival of dental implants in irradiated jaws following treatment of oral cancer: A retrospective study

    Directory of Open Access Journals (Sweden)

    Meenakshi Chauhan Rana

    2016-01-01

    Full Text Available Background: In patients undergoing head and neck surgery for various pathologic conditions, implants are one of the best restorative options and are increasing widely used. Therefore, we evaluated the success of dental implants in the irradiated jaws of patients following treatment of oral cancer oral cancer treated patients. Materials and Methods: Data of oral cancer treated patients was collected retrospectively from 2002 to 2008. We took 46 oral cancer treated patients in which implants were placed in irradiated jaws for rehabilitation. Results: It was found that out of 162 dental implants placed, 52 failed. Furthermore, there was no variation in the implant survival rate in between both the jaws. Radiation dose of <50 Gy units also showed significantly increased amount of implant survival rate. Conclusions: Implant survival is multifactorial and depends upon a number of factors like level of radiation exposure in that area, time gap between last radiation doses etc., Further research is required in this field to improve the esthetics and quality of life of cancer treated patients.

  17. A novel root analogue dental implant using CT scan and CAD/CAM: selective laser melting technology.

    Science.gov (United States)

    Figliuzzi, M; Mangano, F; Mangano, C

    2012-07-01

    Direct laser metal forming (DLMF) is a new technique which allows solids with complex geometry to be produced by annealing metal powder microparticles in a focused laser beam, according to a computer-generated three-dimensional (3D) model. For dental implants, the fabrication process involves the laser-induced fusion of titanium microparticles, in order to build, layer by layer, the desired object. Modern computed tomography (CT) acquisition and 3D image conversion, combined with the DLMF process, allows the fabrication of custom-made, root-analogue implants (RAI), perfect copies of the radicular units that need replacing. This report demonstrates the successful clinical use of a custom-made, root-analogue DLMF implant. CT images of the residual non-restorable root of a right maxillary premolar were acquired and modified with specific software into a 3D model. From this model, a custom-made, root-analogue, DLMF implant was fabricated. Immediately after tooth extraction, the root-analogue implant was placed in the extraction socket and restored with a single crown. At the 1-year follow-up examination, the custom-made implant showed almost perfect functional and aesthetic integration. The possibility of fabricating custom-made, root-analogue DLMF implants opens new interesting perspectives for immediate placement of dental implants. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. In vitro synchrotron-based radiography of micro-gap formation at the implant–abutment interface of two-piece dental implants

    International Nuclear Information System (INIS)

    Rack, A.; Rack, T.; Stiller, M.; Riesemeier, H.; Zabler, S.; Nelson, K.

    2010-01-01

    Micro-radiography using hard X-ray synchrotron radiation is the first potential tool to allow an evaluation of the mechanical behavior of the dental implant–abutment complex during force application, thus enabling the enhancement of the design of dental implants which has been based on theoretical analysis to date. Micro-gap formation at the implant–abutment interface of two-piece dental implants was investigated in vitro using high-resolution radiography in combination with hard X-ray synchrotron radiation. Images were taken with the specimen under different mechanical loads of up to 100 N. The aim of this investigation was to prove the existence of micro-gaps for implants with conical connections as well as to study the mechanical behavior of the mating zone of conical implants during loading. Synchrotron-based radiography in comparison with classical laboratory radiography yields high spatial resolution in combination with high contrast even when exploiting micro-sized features in highly attenuating objects. The first illustration of a micro-gap which was previously indistinguishable by laboratory methods underlines that the complex micro-mechanical behavior of implants requires further in vitro investigations where synchrotron-based micro-imaging is one of the prerequisites

  19. In vitro synchrotron-based radiography of micro-gap formation at the implant–abutment interface of two-piece dental implants

    Energy Technology Data Exchange (ETDEWEB)

    Rack, A., E-mail: arack@snafu.de [European Synchrotron Radiation Facility, Grenoble (France); Rack, T. [Charité, Department of Oral and Maxillofacial Surgery, Clinical Navigation and Robotics, Berlin (Germany); Stiller, M. [Charité, Department of Maxillofacial and Facial-Plastic Surgery, Division of Oral Medicine, Radiology and Surgery, Berlin (Germany); Riesemeier, H. [Bundesanstalt für Materialforschung und -prüfung, Division Structure Analysis, Polymer Analysis, Berlin (Germany); Zabler, S. [Technical University of Berlin, Institute for Materials Engineering (Germany); Nelson, K. [Charité, Department of Oral and Maxillofacial Surgery, Clinical Navigation and Robotics, Berlin (Germany)

    2010-03-01

    Micro-radiography using hard X-ray synchrotron radiation is the first potential tool to allow an evaluation of the mechanical behavior of the dental implant–abutment complex during force application, thus enabling the enhancement of the design of dental implants which has been based on theoretical analysis to date. Micro-gap formation at the implant–abutment interface of two-piece dental implants was investigated in vitro using high-resolution radiography in combination with hard X-ray synchrotron radiation. Images were taken with the specimen under different mechanical loads of up to 100 N. The aim of this investigation was to prove the existence of micro-gaps for implants with conical connections as well as to study the mechanical behavior of the mating zone of conical implants during loading. Synchrotron-based radiography in comparison with classical laboratory radiography yields high spatial resolution in combination with high contrast even when exploiting micro-sized features in highly attenuating objects. The first illustration of a micro-gap which was previously indistinguishable by laboratory methods underlines that the complex micro-mechanical behavior of implants requires further in vitro investigations where synchrotron-based micro-imaging is one of the prerequisites.

  20. The effect of implant macro-thread design on implant stability in the early post-operative period: a randomized, controlled pilot study.

    Science.gov (United States)

    McCullough, Jeffrey J; Klokkevold, Perry R

    2017-10-01

    Available literature suggests there is a transient drop in implant stability from approximately week 0 to week 3-4 as a result of peri-implant bone remodeling as it transitions from a primary, mechanical stability to a secondary, biological stability. Research investigating the influence of macro-thread design on this process is scant. The specific aim of this study was to evaluate the role of macro-thread design on implant stability in the early post-operative healing period using resonance frequency analysis (RFA). Seven patients, each missing at least two posterior teeth in the same arch, were included in the study. Three patients qualified for four implants resulting in a total of 10 matched pairs. All sites were healed (>6 months), non-grafted sites with sufficient bone to place implants. Each site in a matched pair was randomly assigned to receive either a control (Megagen EZ Plus Internal; EZ) or test (Megagen AnyRidge; AR) implant. The test implant incorporates a novel thread design with a wide thread depth and increased thread pitch. RFA was used to determine implant stability quotient (ISQ) values for each implant at the time of placement and weekly for the first 8 weeks. Implants consistently achieved a relatively high insertion torque (30-45 N/cm) and high initial ISQ value (79.8 ± 1.49). Baseline ISQ values for test (AR; 79.55 ± 1.61) and control (EZ; 80.05 ± 1.37) implants were similar. A general pattern of stability from baseline through all eight follow-up evaluations was observed for the test implants. A pattern of decreasing ISQ values was observed for the control implants across the early follow-up evaluations up to week four, where the value plateaued. There was a statistically significant main effect due to implant type (P implant type and time (P implants performed differently at certain time points. Within the limitations of this study, macro-thread design appears to play a role in implant stability in the early post

  1. Implant Stability of Biological Hydroxyapatites Used in Dentistry

    Directory of Open Access Journals (Sweden)

    Maria Piedad Ramírez Fernández

    2017-06-01

    Full Text Available The aim of the present study was to monitor implant stability after sinus floor elevation with two biomaterials during the first six months of healing by resonance frequency analysis (RFA, and how physico-chemical properties affect the implant stability quotient (ISQ at the placement and healing sites. Bilateral maxillary sinus augmentation was performed in 10 patients in a split-mouth design using a bobine HA (BBM as a control and porcine HA (PBM. Six months after sinus lifting, 60 implants were placed in the posterior maxilla. The ISQ was recorded on the day of surgery from RFA at T1 (baseline, T2 (three months, and T3 (six months. Statistically significant differences were found in the ISQ values during the evaluation period. The ISQ (baseline was 63.8 ± 2.97 for BBM and 62.6 ± 2.11 for PBM. The ISQ (T2 was ~73.5 ± 4.21 and 67 ± 4.99, respectively. The ISQ (T3 was ~74.65 ± 2.93 and 72.9 ± 2.63, respectively. All of the used HAs provide osseointegration and statistical increases in the ISQ at baseline, T2 and T3 (follow-up, respectively. The BBM, sintered at high temperature with high crystallinity and low porosity, presented higher stability, which demonstrates that variations in the physico-chemical properties of a bone substitute material clearly influence implant stability.

  2. Dental implants in patients with ectodermal dysplasia: A systematic review.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos

    2018-05-21

    This study sought to assess the clinical outcome and survival rate of oral implants placed in individuals with ectodermal dysplasia (ED), based on previously published studies. An electronic search without time restrictions was undertaken in 5 databases (PubMed/Medline, Web of Science, ScienceDirect, J-Stage, Lilacs). Descriptive statistics, Kaplan Meier estimator and implant failure probability were calculated. 90 publications were included, reporting 228 ED patients that received 1472 implants (1392 conventional, 47 zygomatic, 33 mini-implants). Mean age of the patients was 20.2 ± 6.8 years (2-56). Patients had a mean of 3.2 ± 2.5 maxillary and 2.1 ± 2.6 mandibular permanent teeth (min-max, 0-14). Patients received a mean of 8.2 ± 3.8 implants (1-20). Most implants were placed in the third decade of life, 24.6% of the implants were placed in children (0-17 years of age). 1391 implants had information on follow-up (72 failures, 5.2%). The 20-year CSR was 84.6%. The probability of failure was 4.5% (95%CI 3.5%-5.6%, p < 0.001). Additional treatments performed were Le Fort I (99 implants, 20 patients, 3.5% failed), grafting (497 implants, 77 patients, 5.2% failed), distraction osteogenesis (79 implants, 16 patients, 10.1% failed). Mean follow-up was 42.9 ± 41.9 months (min-max, 2-240). Dental implants placed in ED patients, either infants or adults, present a high survival rate (20-year CSR 84.6%). Copyright © 2018 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  3. A Comparative Study of Spiral Tomograms with Different Slice Thicknesses in Dental Implant Planning

    International Nuclear Information System (INIS)

    Yoon Sook Ja

    1999-01-01

    To know whether there would be a difference among spiral tomograms of different slice thicknesses in the measurement of distances which are used for dental implant planning. 10 dry mandibules and 40 metal balls are used to take total 120 Scanora tomograms with the slice thickness of 2 mm, 4 mm and 8 mm. 3 oral radiologists interpreted each tomogram to measure the distances from the mandibular canal to the alveoalr crest and buccal, lingual and inferior borders of mandible. 3 observers recorded grades of 0, 1 or 2 to evaluate the perceptibility of alveolar crest and the superior border of mandibular canal. For statistical analysis, ANOVA with repeated measure, Chi-square tests and intraclass correlation coefficient (R2, alpha) were used. There was not a statistically significant difference among spiral tomograms with different slice thicknesses in the measurement of the distances and in the perceptibility of alveolar crest and mandibular canal (p>0.05). All of them showed a good relationship in the reliability analysis. The perceptibility of alveolar crest and mandibular canal was almost similar and an excellent relationship was seen on all of them. There would be no significant difference, no matter which spiral tomogram of any slice thickness may be used in dental implant planning, considering the thickness of dental implant fixture.

  4. Influence of extracellular matrix coatings on implant stability and osseointegration: an animal study.

    Science.gov (United States)

    Stadlinger, Bernd; Pilling, Eckart; Huhle, Matthias; Mai, Ronald; Bierbaum, Susanne; Bernhardt, Ricardo; Scharnweber, Dieter; Kuhlisch, Eberhard; Hempel, Ute; Eckelt, Uwe

    2007-10-01

    Aim of the present study was to test the hypothesis that the application of components of the extracellular matrix such as glycosaminoglycans used as implant surface coatings in combination with collagen, with and without growth factor, can lead to enhanced ossification and thus improve implant stability compared with collagen coatings alone. Twenty miniature pigs received 120 experimental titanium implants in the mandible. Three types of surface coatings were created: (1) collagen type I (coll), (2) collagen type I/chondroitin sulphate (coll/CS), (3) collagen type I/chondroitin sulphate/BMP-4 (coll/CS/BMP). Periimplant bone formation was assessed within a defined recess along the length axis of the implant. Bone-implant contact (BIC) and bone volume density (BVD) were determined, using both histomorphometry and synchrotron radiation micro computed tomography (SRmicroCT). To measure implant stability, resonance frequency analysis was applied after implantation and 1, 3, 7, and 22 weeks after placement. BIC was highest for coll/CS coated implants, followed by coll, p = 0.082. Histomorphometric BVD did not significantly change for any coating. SRmicroCT analysis showed an increased BVD for collagen coated implants, compared with the other two surface coatings. Implant stability showed a decrease for all coatings up to the third week. At 22 weeks, all coatings showed an increase in stability without reaching their initial level. Highest stability was reached for coll coated implants, p = 0.051. It was concluded that collagen and coll/CS implant coatings have advantageous characteristics for peri-implant bone formation, compared with the further integration of BMP-4.

  5. In Vitro Laser Treatment Platform Construction with Dental Implant Thread Surface on Bacterial Adhesion for Peri-Implantitis

    Directory of Open Access Journals (Sweden)

    Hsien-Nan Kuo

    2017-01-01

    Full Text Available This study constructs a standard in vitro laser treatment platform with dental implant thread surface on bacterial adhesion for peri-implantitis at different tooth positions. The standard clinical adult tooth jaw model was scanned to construct the digital model with 6 mm bone loss depth on behalf of serious peri-implantitis at the incisor, first premolar, and first molar. A cylindrical suite connected to the implant and each tooth root in the jaw model was designed as one experimental unit set to allow the suite to be replaced for individual bacterial adhesion. The digital peri-implantitis and suite models were exported to fulfill the physical model using ABS material in a 3D printer. A 3 mm diameter specimen implant on bacterial adhesion against Escherichia coli was performed for gram-negative bacteria. An Er:YAG laser, working with a chisel type glass tip, was moved from the buccal across the implant thread to the lingual for about 30 seconds per sample to verify the in vitro laser treatment platform. The result showed that the sterilization rate can reach 99.3% and the jaw model was not damaged after laser irradiation testing. This study concluded that using integrated image processing, reverse engineering, CAD system, and a 3D printer to construct a peri-implantitis model replacing the implant on bacterial adhesion and acceptable sterilization rate proved the feasibility of the proposed laser treatment platform.

  6. Tasa de supervivencia de los implantes dentales de óxido de circonio. Una revisión sistemática y metaanálisis

    Directory of Open Access Journals (Sweden)

    Heber Isac Arbildo-Vega

    2017-07-01

    Conclusión: La literatura revisada señala que los implantes dentales de óxido de circonio poseen la misma tasa de supervivencia que los implantes dentales de titanio, sin embargo, se necesitan más investigaciones para recomendar su uso clínico.

  7. Effect of different types of prosthetic platforms on stress-distribution in dental implant-supported prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Minatel, Lurian [Pró-Reitoria de Pesquisa e Pós-graduação (PRPPG), Universidade do Sagrado Coração, USC, 10–50 Irmã Armindal, Jardim Brasil, Bauru, 17011–160, SP (Brazil); Verri, Fellippo Ramos [Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, 1193 José Bonifácio Street, Vila Mendonça, Araçatuba 16015–050 (Brazil); Kudo, Guilherme Abu Halawa [Pró-Reitoria de Pesquisa e Pós-graduação (PRPPG), Universidade do Sagrado Coração, USC, 10–50 Irmã Armindal, Jardim Brasil, Bauru, 17011–160, SP (Brazil); Faria Almeida, Daniel Augusto de; Souza Batista, Victor Eduardo de; Aparecido Araujo Lemos, Cleidiel; Piza Pellizzer, Eduardo [Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, 1193 José Bonifácio Street, Vila Mendonça, Araçatuba 16015–050 (Brazil); and others

    2017-02-01

    A biomechanical analysis of different types of implant connections is relevant to clinical practice because it may impact the longevity of the rehabilitation treatment. Therefore, the objective of this study is to evaluate the Morse taper connections and the stress distribution of structures associated with the platform switching (PSW) concept. It will do this by obtaining data on the biomechanical behavior of the main structure in relation to the dental implant using the 3-dimensional finite element methodology. Four models were simulated (with each containing a single prosthesis over the implant) in the molar region, with the following specifications: M1 and M2 is an external hexagonal implant on a regular platform; M3 is an external hexagonal implant using PSW concept; and M4 is a Morse taper implant. The modeling process involved the use of images from InVesalius CT (computed tomography) processing software, which were refined using Rhinoceros 4.0 and SolidWorks 2011 CAD software. The models were then exported into the finite element program (FEMAP 11.0) to configure the meshes. The models were processed using NeiNastram software. The main results are that M1 (regular diameter 4 mm) had the highest stress concentration area and highest microstrain concentration for bone tissue, dental implants, and the retaining screw (P < 0.05). Using the PSW concept increases the area of the stress concentrations in the retaining screw (P < 0.05) more than in the regular platform implant. It was concluded that the increase in diameter is beneficial for stress distribution and that the PSW concept had higher stress concentrations in the retaining screw and the crown compared to the regular platform implant. - Highlights: • The external hexagon implants was unfavorable biomechanical. • The Morse taper implant presented the best biomechanical result. • Platform switching concept increased stress in screw-retained prostheses.

  8. Effect of different types of prosthetic platforms on stress-distribution in dental implant-supported prostheses

    International Nuclear Information System (INIS)

    Minatel, Lurian; Verri, Fellippo Ramos; Kudo, Guilherme Abu Halawa; Faria Almeida, Daniel Augusto de; Souza Batista, Victor Eduardo de; Aparecido Araujo Lemos, Cleidiel; Piza Pellizzer, Eduardo

    2017-01-01

    A biomechanical analysis of different types of implant connections is relevant to clinical practice because it may impact the longevity of the rehabilitation treatment. Therefore, the objective of this study is to evaluate the Morse taper connections and the stress distribution of structures associated with the platform switching (PSW) concept. It will do this by obtaining data on the biomechanical behavior of the main structure in relation to the dental implant using the 3-dimensional finite element methodology. Four models were simulated (with each containing a single prosthesis over the implant) in the molar region, with the following specifications: M1 and M2 is an external hexagonal implant on a regular platform; M3 is an external hexagonal implant using PSW concept; and M4 is a Morse taper implant. The modeling process involved the use of images from InVesalius CT (computed tomography) processing software, which were refined using Rhinoceros 4.0 and SolidWorks 2011 CAD software. The models were then exported into the finite element program (FEMAP 11.0) to configure the meshes. The models were processed using NeiNastram software. The main results are that M1 (regular diameter 4 mm) had the highest stress concentration area and highest microstrain concentration for bone tissue, dental implants, and the retaining screw (P < 0.05). Using the PSW concept increases the area of the stress concentrations in the retaining screw (P < 0.05) more than in the regular platform implant. It was concluded that the increase in diameter is beneficial for stress distribution and that the PSW concept had higher stress concentrations in the retaining screw and the crown compared to the regular platform implant. - Highlights: • The external hexagon implants was unfavorable biomechanical. • The Morse taper implant presented the best biomechanical result. • Platform switching concept increased stress in screw-retained prostheses.

  9. Biomechanical evaluation of different abutment-implant connections - A nonlinear finite element analysis

    Science.gov (United States)

    Ishak, Muhammad Ikman; Shafi, Aisyah Ahmad; Rosli, M. U.; Khor, C. Y.; Zakaria, M. S.; Rahim, Wan Mohd Faizal Wan Abd; Jamalludin, Mohd Riduan

    2017-09-01

    The success of dental implant surgery is majorly dependent on the stability of prosthesis to anchor to implant body as well as the integration of implant body to bone. The attachment between dental implant body and abutment plays a vital role in attributing to the stability of dental implant system. A good connection between implant body cavity to abutment may minimize the complications of abutment loosening and implant fractures as widely reported in clinical findings. The aim of this paper is to investigate the effect of different abutment-implant connections on stress dispersion within the abutment and implant bodies as well as displacement of implant body via three-dimensional (3-D) finite element analysis (FEA). A 3-D model of mandible was reconstructed from computed tomography (CT) image datasets using an image-processing software with the selected region of interest was the left side covering the second premolar, first molar and second molar regions. The bone was modelled as compact (cortical) and porous (cancellous) structures. Besides, three implant bodies and three generic models of abutment with different types of connections - tapered interference fit (TIF), tapered integrated screwed-in (TIS) and screw retention (SR) were created using computer-aided design (CAD) software and all models were then analysed via 3D FEA software. Occlusal forces of 114.6 N, 17.2 N and 23.4 N were applied in the axial, lingual and mesio-distal directions, respectively, on the top surface of first molar crown. All planes of the mandibular bone model were rigidly fixed. The result exhibited that abutment with TIS connection produced the most favourable stress and displacement outcomes as compared to other attachment types. This is due to the existence of integrated screw at the bottom portion of tapered abutment which increases the motion resistance.

  10. Preferred Source and Perceived Need of More Information about Dental Implants by the Undergraduate Dental Students of Nepal: All Nepal Survey

    OpenAIRE

    Sharma, Arati; Shrestha, Bidhan; Chaudhari, Bijay Kumar; Suwal, Pramita; Singh, Raj Kumar; Niraula, Surya Raj; Parajuli, Prakash Kumar

    2018-01-01

    Objectives. This study was conducted to know the preferred source and perceived need of more information about dental implants by the undergraduate students of Nepal and their association with academic levels and gender. Materials and Methods. It was conducted in all the dental colleges of Nepal from June 2016 to June 2017 after taking ethical clearance and approval from the research committee of BPKIHS. It included all those who were present at the time of survey. Data collection was done th...

  11. Clinical follow-up of unilateral, fixed dental prosthesis on maxillary implants.

    Science.gov (United States)

    Wahlström, Monica; Sagulin, Gun-Britt; Jansson, Leif E

    2010-11-01

    The aims of the present study were to evaluate (1) the success rate of unilateral maxillary fixed dental prosthesis (FDPs) on implants in patients at a periodontal clinic referred for periodontal treatment, (2) the prevalence of varying mechanical and biological complications and (3) effects of potential risk factors on the success rate. Fifty consecutive patients were invited to participate in a follow-up. The patients had received FDPs on implants between November 2000 and December 2003 after treatment to achieve optimal peridontal health, and the FDPs had been in function for at least 3 years. A questionnaire was sent to the patients before the follow-up examination. Forty-six patients with 116 implants were examined. The follow-up comprised clinical and radiographic examinations and evaluations of treatment outcome. Before implant treatment, 13% of the teeth were extracted; of these, 80% were extracted due to periodontal disease. No implants had been lost before implant loading. One implant in one patient fractured after 3 years of functional loading and three implants in another patient after 6.5 years. The most frequent mechanical complications were veneer fractures and loose bridge screws. Patients with peri-implant mucositis had significantly more bleeding on probing around teeth and implants. Patients with peri-implantitis at the follow-up had more deep periodontal pockets around their remaining teeth compared with individuals without peri-implantitis, but these differences were not significant. Smokers had significantly fewer teeth, more periodontal pockets ≥ 4mm and a tendency towards greater marginal bone loss at the follow-up, compared with non-smokers. In the short term, overloading and bruxism seem more hazardous for implant treatment, compared with a history of periodontitis.

  12. Comparative analysis of stress in a new proposal of dental implants.

    Science.gov (United States)

    Valente, Mariana Lima da Costa; de Castro, Denise Tornavoi; Macedo, Ana Paula; Shimano, Antonio Carlos; Dos Reis, Andréa Cândido

    2017-08-01

    The purpose of this study was to compare, through photoelastic analysis, the stress distribution around conventional and modified external hexagon (EH) and morse taper (MT) dental implant connections. Four photoelastic models were prepared (n=1): Model 1 - conventional EH cylindrical implant (Ø 4.0mm×11mm - Neodent®), Model 2 - modified EH cylindrical implant, Model 3 - conventional MT Conical implant (Ø 4.3mm×10mm - Neodent®) and Model 4 - modified MT conical implant. 100 and 150N axial and oblique loads (30° tilt) were applied in the devices coupled to the implants. A plane transmission polariscope was used in the analysis of fringes and each position of interest was recorded by a digital camera. The Tardy method was used to quantify the fringe order (n), that calculates the maximum shear stress (τ) value in each selected point. The results showed lower stress concentration in the modified cylindrical implant (EH) compared to the conventional model, with application of 150N axial and 100N oblique loads. Lower stress was observed for the modified conical (MT) implant with the application of 100 and 150N oblique loads, which was not observed for the conventional implant model. The comparative analysis of the models showed that the new design proposal generates good stress distribution, especially in the cervical third, suggesting the preservation of bone tissue in the bone crest region. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Studies of the quality of the intraosseous dental implant bed and of thermal effects in implant pathology

    International Nuclear Information System (INIS)

    Wong, K.

    2000-01-01

    Dental implants may offer solutions to problems of tooth loss and removable dentures, avoiding the blighting of sound teeth in conventional bridgework. However, there may be severe problems due to deficient and poor quality host bone, particularly in the maxillary sinus region. The success of particulate irradiated mineralised cancellous allograft (IMCA) in generating new bone in the sinus was analysed using the trephine bone cores removed to create an implant bed. Bone cores were embedded and examined using 3D fluorescence fight microscopy and scanning electron microscopy in the backscattered electron (BSE) mode to study the quantity and the quality [degree of mineralisation] of bone in implant sites. In all graft cases, new bone as immature (woven) or mature (lamellar) bone formed on the surfaces of the allograft. The bone volume fraction was found to be significantly greater within 5 mm height of the host sinus floor. In an extended study, control sinuses grafted with IMCA soaked in saline showed no significant difference to the test side treated with the patient's own serum. IMCA was shown to retain much of its original topographical and morphological characteristics. Biopsy core specimens from other (non-sinus) sites in both maxilla and mandible were treated similarly. The highest mineral density distributions were observed in the mandible, with the lowest in the residual posterior maxilla beneath the sinus floor. A novel quantitative bone quality scale is proposed to include three parameters of bone quality: mineralisation density, bone volume fraction and connectivity. Clinical use of Laser Doppler Flowmetry (LDF) confirmed positive blood flow in grafts, sinus membrane, and oral tissues. A model of heat conduction in dental implants, predicted oral heat to be a possible factor in implant pathology. The effect of temperature on avian osteoclastic resorption in vitro was studied using a volumetric pit assay. Osteoclastic function measured as volumes and depths

  14. Optical stability under photo-irradiation of urushi films by ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Awazu, Kaoru; Funada, Yoshinori; Kasamori, Masato; Sakamoto, Makoto; Ichikawa, Tachio [Industrial Research Inst. of Ishikawa, Kanazawa (Japan)

    1995-06-01

    Nitrogen ions, argon ions and others were implanted in urushi-coated surfaces by using a simplified ion implantation apparatus, and the optical stability test was carried out by a sunshine weather meter. The rate of remaining luster on urushi-coated surfaces accompanying ultraviolet irradiation showed respective peculiar behavior according to the kinds of the implanted ions, the time of implantation, transparent and black urushi films, and the use of brightener or not. In electron beam irradiation, change hardly occurred. In urushi-coated products, the luster and the properties are maintained for long period, therefore recently, urushi coating has become to be applied to road sign panels and notice boards in addition to lacquer wares and applied fine art products, and the improvement of the optical stability of urushi films has become the subject. In this study, the experimental methods on urushi coating, ion implantation, the optical stability test and measuring method are explained. The changes of urushi film luster, transmittance, haze, lightness, and chromaticity by nitrogen ion implantation are reported. (K.I.).

  15. Optical stability under photo-irradiation of urushi films by ion implantation

    International Nuclear Information System (INIS)

    Awazu, Kaoru; Funada, Yoshinori; Kasamori, Masato; Sakamoto, Makoto; Ichikawa, Tachio

    1995-01-01

    Nitrogen ions, argon ions and others were implanted in urushi-coated surfaces by using a simplified ion implantation apparatus, and the optical stability test was carried out by a sunshine weather meter. The rate of remaining luster on urushi-coated surfaces accompanying ultraviolet irradiation showed respective peculiar behavior according to the kinds of the implanted ions, the time of implantation, transparent and black urushi films, and the use of brightener or not. In electron beam irradiation, change hardly occurred. In urushi-coated products, the luster and the properties are maintained for long period, therefore recently, urushi coating has become to be applied to road sign panels and notice boards in addition to lacquer wares and applied fine art products, and the improvement of the optical stability of urushi films has become the subject. In this study, the experimental methods on urushi coating, ion implantation, the optical stability test and measuring method are explained. The changes of urushi film luster, transmittance, haze, lightness, and chromaticity by nitrogen ion implantation are reported. (K.I.)

  16. Evaluation of Stress Distribution of Mini Dental Implant-Supported Overdentures in Complete Cleft Palate Models: A Three-Dimensional Finite Element Analysis Study.

    Science.gov (United States)

    Soğancı, Gökçe; Yazıcıoğlu, Hüseyin

    2016-01-01

    Mini dental implants could be an alternative treatment method for prosthetic treatment of edentulous cleft palate. The aim of this study was to analyze stress distribution around the cortical bone and different plans using a varied number of mini dental implants in edentulous unilateral complete cleft palates. Three edentulous maxillary models were modified to create unilateral complete cleft palates. Mini dental implants (2.4 × 15 mm) were located as two mini implants at the premolar region, four mini implants at the premolar and molar region, and six mini implants at the first premolar, second premolar, and first molar regions in the models, respectively. Mucosa, o-ring/ball attachments, and overdentures were simulated. Vertical and horizontal loads of 100 N were applied on both the right and left molar teeth of the overdenture for each model. Maximum and minimum principal stress values and the distribution at cortical bone around the implants and cleft palates were evaluated by finite element analysis. Stress values under vertical loads were lower than values under horizontal loadings for all models. Stress values were found to be lower in the first model than in the second and third models. The highest stress values were found around implants in the second model. The unilateral feature of a complete cleft pattern affected the stress distribution. Stresses occured mostly around implants when the overdenture was supported by six implants; however, the stress distribution around implants was low with two implants because of tissue support.

  17. The efficacy of antibiotic prophylaxis at placement of dental implants: a Cochrane systematic review of randomised controlled clinical trials.

    Science.gov (United States)

    Esposito, Marco; Grusovin, Maria Gabriella; Coulthard, Paul; Oliver, Richard; Worthington, Helen V

    To assess the beneficial or harmful effects of systemic prophylactic antibiotics at dental implant placement versus no antibiotic/placebo administration and, if antibiotics are of benefit, to find which type, dosage and duration is the most effective. The Cochrane Oral Health Group's Trials Register, CENTRAL, MEDLINE and EMBASE were searched and several journals were handsearched with no language restriction up to January 2008. Randomised controlled trials (RCTs) with a follow up of at least 3 months comparing the administration of various prophylactic antibiotic regimens versus no antibiotics to patients undergoing dental implant placement were eligible. Screening of studies, quality assessment and data extraction were conducted in duplicate. Missing information was requested. Outcome measures were: prosthesis and implant failures, postoperative infections and adverse events (gastrointestinal, hypersensitivity, etc.). Two RCTs were identified: one comparing 2 g of preoperative amoxicillin versus placebo (316 patients) and the other comparing 2 g of preoperative amoxicillin + 500 mg four times a day for 2 days versus no antibiotics (80 patients). The meta-analyses of the two trials showed a statistically significant higher number of patients experiencing implant failures in the group not receiving antibiotics: RR = 0.22 (95% CI 0.06 to 0.86). The number needed to treat (NNT) to prevent one patient having an implant failure is 25 (95% CI 13 to 100), based on a patient implant failure rate of 6% in patients not receiving antibiotics. The other outcomes were not statistically significant, and only two minor adverse events were recorded, one of which was in the placebo group. There is some evidence suggesting that 2 g of amoxicillin given 1 hour preoperatively significantly reduce failures of dental implants placed in ordinary conditions. It remains unclear whether postoperative antibiotics are beneficial, and which is the most effective antibiotic. It might be

  18. Effect of implantoplasty on fracture resistance and surface roughness of standard diameter dental implants.

    Science.gov (United States)

    Costa-Berenguer, Xavier; García-García, Marta; Sánchez-Torres, Alba; Sanz-Alonso, Mariano; Figueiredo, Rui; Valmaseda-Castellón, Eduard

    2018-01-01

    To assess the effect of implantoplasty on the fracture resistance, surface roughness, and macroscopic morphology of standard diameter (4.1 mm) external connection dental implants. An in vitro study was conducted in 20 screw-shaped titanium dental implants with an external connection. In 10 implants, the threads and surface were removed and polished with high-speed burs (implantoplasty), while the remaining 10 implants were used as controls. The final implant dimensions were recorded. The newly polished surface quality was assessed by scanning electron microscopy (SEM) and by 3D surface roughness analysis using a confocal laser microscope. Finally, all the implants were subjected to a mechanical pressure resistance test. A descriptive analysis of the data was made. Also, Student's t tests were employed to detect differences regarding the compression tests. Implantoplasty was carried out for a mean time of 10 min and 48 s (standard deviation (SD) of 1 min 22 s). Macroscopically, the resulting surface had a smooth appearance, although small titanium shavings and silicon debris were present. The final surface roughness (S a values 0.1 ± 0.02 μm) was significantly lower than that of the original (0.75 ± 0.08 μm S a ) (p = .005). There was minimal reduction in the implant's inner body diameter (0.19 ± 0.03 mm), and no statistically significant differences were found between the test and control implants regarding the maximum resistance force (896 vs 880 N, respectively). Implantoplasty, although technically demanding and time-consuming, does not seem to significantly alter fracture resistance of standard diameter external connection implants. A smooth surface with S a values below 0.1 μm can be obtained through the use of silicon polishers. A larger sample is required to confirm that implantoplasty does not significantly affect the maximum resistance force of standard diameter external connection implants. © 2017 John Wiley & Sons A/S. Published

  19. Use of Antibiotic Prophylaxis for Tooth Extractions, Dental Implants, and Periodontal Surgical Procedures.

    Science.gov (United States)

    Suda, Katie J; Henschel, Heather; Patel, Ursula; Fitzpatrick, Margaret A; Evans, Charlesnika T

    2018-01-01

    Guidelines for antibiotics prior to dental procedures for patients with specific cardiac conditions and prosthetic joints have changed, reducing indications for antibiotic prophylaxis. In addition to guidelines focused on patient comorbidities, systematic reviews specific to dental extractions and implants support preprocedure antibiotics for all patients. However, data on dentist adherence to these recommendations are scarce. This was a cross-sectional study of veterans undergoing tooth extractions, dental implants, and periodontal procedures. Patients receiving antibiotics for oral or nonoral infections were excluded. Data were collected through manual review of the health record. Of 183 veterans (mean age, 62 years; 94.5% male) undergoing the included procedures, 82.5% received antibiotic prophylaxis (mean duration, 7.1 ± 1.6 days). Amoxicillin (71.3% of antibiotics) and clindamycin (23.8%) were prescribed most frequently; 44.7% of patients prescribed clindamycin were not labeled as penicillin allergic. Of those who received prophylaxis, 92.1% received postprocedure antibiotics only, 2.6% received preprocedural antibiotics only, and 5.3% received pre- and postprocedure antibiotics. When prophylaxis was indicated, 87.3% of patients received an antibiotic. However, 84.9% received postprocedure antibiotics when preprocedure administration was indicated. While the majority of antibiotics were indicated, only 8.2% of patients received antibiotics appropriately. The primary reason was secondary to prolonged duration. Three months postprocedure, there were no occurrences of Clostridium difficile infection, infective endocarditis, prosthetic joint infections, or postprocedure oral infections. The majority of patients undergoing a dental procedure received antibiotic prophylaxis as indicated. Although patients for whom antibiotic prophylaxis was indicated should have received a single preprocedure dose, most antibiotics were prescribed postprocedure. Dental stewardship

  20. A three-dimensional finite element study on the effect of hydroxyapatite coating thickness on the stress distribution of the surrounding dental implant-bone interface

    Directory of Open Access Journals (Sweden)

    Hadi Asgharzadeh Shirazi

    2014-06-01

    Full Text Available   Background and Aims: Hydroxyapatite coating has allocated a special place in dentistry due to its biocompatibility and bioactivity. The purpose of this study was to evaluate the relation between the hydroxyapatite thickness and stress distribution by using finite element method.   Materials and Methods: In this paper, the effect of hydroxyapatite coating thickness on dental implants was studied using finite element method in the range between 0 to 200 microns. A 3D model including one section of mandible bone was modeled by a thick layer of cortical surrounding dense cancellous and a Nobel Biocare commercial brand dental implant was simulated and analyzed under static load in the Abaqus software.   Results The diagram of maximum von Mises stress versus coating thickness was plotted for the cancellous and cortical bones in the range between 0 to 200 microns. The obtained results showed that the magnitude of maximum von Mises stress of bone decreased as the hydroxyapatite coating thickness increased. Also, the thickness of coating exhibited smoother stress distribution and milder variations of maximum von Mises stress in a range between 60 to 120 microns.   Conclusion: In present study, the stress was decreased in the mandible bone where hydroxyapatite coating was used. This stress reduction leads to a faster stabilization and fixation of implant in the mandible bone. Using hydroxyapatite coating as a biocompatible and bioactive material could play an important role in bone formation of implant- bone interface.

  1. Clinical and radiological results of patients treated with three treatment modalities for overdentures on implants of the ITI (R) Dental Implant System - A randomized controlled clinical trial

    NARCIS (Netherlands)

    Wismeijer, D; van Waas, MAJ; Mulder, J; Vermeeren, JIJF; Kalk, W

    In a randomized controlled clinical trial carried out at the Ignatius teaching hospital in Breda, The Netherlands, 110 edentulous patients with severe mandibular bone loss were treated with implants of the ITI(R) Dental Implant System using 3 different treatment strategies: a mandibular overdenture

  2. Reliability of linear distance measurement for dental implant length with standardized periapical radiographs

    International Nuclear Information System (INIS)

    Wakoh, Mamoru; Harada, Takuya; Otonari, Takamichi

    2006-01-01

    The purpose of this study was to investigate the accuracy of distance measurements of implant length based on periapical radiographs compared with that of other modalities. We carried out an experimental trial to compare precision in distance measurement. Dental implant fixtures were buried in the canine and first molar regions. These were then subjected to periapical (PE) radiography, panoramic (PA) radiography conventional (CV) and medical computed (CT) tomography. The length of the implant fixture on each film was measured by nine observers and degree of precision was statistically analyzed. The precision of both PE radiographs and CT tomograms was closest at the highest level. Standardized PE radiography, in particular, was superior to CT tomography in the first molar region. This suggests that standardized PE radiographs should be utilized as a reliable modality for longitudinal and linear distance measurement, depending on implant length at local implantation site. (author)

  3. 10-year survival rate and the incidence of peri-implant disease of 374 titanium dental implants with a SLA surface: a prospective cohort study in 177 fully and partially edentulous patients

    NARCIS (Netherlands)

    van Velzen, F.J.J.; Ofec, R.; Schulten, E.A.J.M.; ten Bruggenkate, C.M.

    2015-01-01

    Purpose This prospective cohort study evaluates the 10-year survival and incidence of peri-implant disease at implant and patient level of sandblasted, large grid, and acid-etched titanium dental implants (Straumann, soft tissue level, SLA surface) in fully and partially edentulous patients.

  4. Modelling dental implant extraction by pullout and torque procedures.

    Science.gov (United States)

    Rittel, D; Dorogoy, A; Shemtov-Yona, K

    2017-07-01

    Dental implants extraction, achieved either by applying torque or pullout force, is used to estimate the bone-implant interfacial strength. A detailed description of the mechanical and physical aspects of the extraction process in the literature is still missing. This paper presents 3D nonlinear dynamic finite element simulations of a commercial implant extraction process from the mandible bone. Emphasis is put on the typical load-displacement and torque-angle relationships for various types of cortical and trabecular bone strengths. The simulations also study of the influence of the osseointegration level on those relationships. This is done by simulating implant extraction right after insertion when interfacial frictional contact exists between the implant and bone, and long after insertion, assuming that the implant is fully bonded to the bone. The model does not include a separate representation and model of the interfacial layer for which available data is limited. The obtained relationships show that the higher the strength of the trabecular bone the higher the peak extraction force, while for application of torque, it is the cortical bone which might dictate the peak torque value. Information on the relative strength contrast of the cortical and trabecular components, as well as the progressive nature of the damage evolution, can be revealed from the obtained relations. It is shown that full osseointegration might multiply the peak and average load values by a factor 3-12 although the calculated work of extraction varies only by a factor of 1.5. From a quantitative point of view, it is suggested that, as an alternative to reporting peak load or torque values, an average value derived from the extraction work be used to better characterize the bone-implant interfacial strength. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Microscopic Study of Surface Microtopographic Characteristics of Dental Implants

    Science.gov (United States)

    Sezin, M.; Croharé, L.; Ibañez, J.C.

    2016-01-01

    Objective: To determine and compare the micro topographic characteristics of dental implants submitted to different surface treatments, using scanning electron microscopy (SEM). Materials and Methods: Implants were divided into 7 groups of 3 specimens each, according to the surface treatment used: group 1: Osseotite, BIOMET 3i; group 2: SLA surface, Institut Straumann AG; group 3: Oxalife surface, Tree-Oss implant; group 4: B&W implant surface; group 5: Q-implant surface; group 6: ML implant surface; group 7: RBM surface, Rosterdent implant. The surfaces were examined under SEM (Carl Zeiss FE-SEM-SIGMA). Image Proplus software was used to determine the number and mean diameter of pores per area unit (mm). The data obtained were analyzed with the Mann-Whitney test. A confocal laser microscope (LEXT-OLS4100 Olympus) was used to conduct the comparative study of surface roughness (Ra). Data were analyzed using Tukey's HSD test. Results: The largest average pore diameter calculated in microns was found in group 5 (3.45 µm+/-1.91) while the smallest in group 7 (1.47µm+/-1.29). Significant differences were observed among each one of the groups studied (p<0.05). The largest number of pores/mm2 was found in group 2 (229343) and the smallest number in group 4 (10937). Group 2 showed significant differences regarding the other groups (p<0.05). The greatest roughness (Ra) was observed in group 2 (0.975µm+/-0.115) and the smallest in group 4 (0.304µm+/-0.063). Group 2 was significantly different from the other groups (p<0.05). Conclusion: The micro topography observed in the different groups presented dissimilar and specific features, depending on the chemical treatment used for the surfaces.. PMID:27335615

  6. Bifosfonatos e implantes dentales, ¿son incompatibles? Revisión de la literatura

    Directory of Open Access Journals (Sweden)

    Manuel Moreno-Sánchez

    2016-07-01

    Conclusiones: El tratamiento con bifosfonatos no disminuye la osteointegración del implante dental, aunque estos resultados se han obtenido en base a estudios retrospectivos en humanos. Se han descrito casos de osteonecrosis de los maxilares relacionada con bifosfonatos en estos pacientes, sobre todo tras tratamiento prolongado.

  7. Purposeful exposure of a polylactic acid barrier to achieve socket preservation for placement of dental implants: case series report.

    Science.gov (United States)

    Rosen, Paul S; Rosen, Adam D

    2013-01-01

    This retrospective case series reports on the use of a polylactic acid barrier that was left exposed in the process of socket preparation for the placement of dental implants. A retrospective chart review found 43 patients with 48 extraction sockets that were treated in this manner. Teeth were removed and the sockets were thoroughly debrided, with 40 of them receiving a bone replacement graft covered by the polylactic acid barrier and the additional 8 receiving the membrane alone. Suturing left the barrier exposed, and the sites were re-entered on average at 23 weeks for the placement of a dental implant. All sites were able to receive a dental implant, demonstrating the ability to leave a polylactic acid barrier exposed and achieve successful guided bone regeneration (GBR) results. This ultimately helped avoid some of the negative sequelae of trying to achieve primary closure of the flaps at the time of tooth extraction.

  8. Updates on ultrasound research in implant dentistry: a systematic review of potential clinical indications.

    Science.gov (United States)

    Bhaskar, Vaishnavi; Chan, Hsun-Liang; MacEachern, Mark; Kripfgans, Oliver D

    2018-05-23

    Ultrasonography has shown promising diagnostic value in dental implant imaging research; however, exactly how ultrasound was used and at what stage of implant therapy it can be applied has not been systematically evaluated. Therefore, the aim of this review is to investigate potential indications of ultrasound use in the three implant treatment phases, namely planning, intraoperative and postoperative phase. Eligible manuscripts were searched in major databases with a combination of key words related to the use of ultrasound imaging in implant therapy. An initial search yielded 414 articles, after further review, 28 articles were finally included for this systematic review. Ultrasound was found valuable, though at various development stages, for evaluating (1) soft tissues, (2) hard tissues (3) vital structures and (4) implant stability. B-mode, the main function to image anatomical structures of interest, has been evaluated in pre-clinical and clinical studies. Quantitative ultrasound parameters, e.g. sound speed and amplitude, are being developed to evaluate implant-bone stability, mainly in simulation and pre-clinical studies. Ultrasound could be potentially useful in all 3 treatment phases. In the planning phase, ultrasound could evaluate vital structures, tissue biotype, ridge width/density, and cortical bone thickness. During surgery, it can provide feedback by identifying vital structures and bone boundary. At follow-up visits, it could evaluate marginal bone level and implant stability. Understanding the current status of ultrasound imaging research for implant therapy would be extremely beneficial for accelerating translational research and its use in dental clinics.

  9. Effects of continual intermittent administration of parathyroid hormone on implant stability in the presence of osteoporosis: an in vivo study using resonance frequency analysis in a rabbit model

    Directory of Open Access Journals (Sweden)

    Yoshifumi Oki

    Full Text Available Abstract Objective: This study aimed to evaluate the effects of continual intermittent administration of parathyroid hormone (PTH on implant stability in the presence of osteoporosis, using rabbit models. Material and Methods: Fifteen female New Zealand white rabbits underwent ovariectomy and were administered glucocorticoids to induce osteoporosis, following which they were divided into three groups. The first group received intermittent subcutaneous PTH for 4 weeks until implant placement (PTH1, while the second and third groups received PTH (PTH2 and saline (control, respectively, for 4 weeks before and after implant placement. After intermittent administration of PTH or saline, titanium implants were inserted into the left femoral epiphyses of all animals, and the implant stability quotient (ISQ was measured immediately after placement to assess the primary stability and at 2 and 4 weeks after implant placement to assess osseointegration. At 4 weeks after implant placement, histological and histomorphometric evaluations were conducted and the bone area around the implant socket was measured as a ratio of the total bone area to the total tissue area. Results: Regarding primary stability, the ISQ values for the PTH1 and PTH2 groups were significantly higher than those for the control group (p<0.05. Concerning osseointegration, the ISQ values at 2 and 4 weeks were significantly higher for the PTH2 group than for the PTH1 and control (p<0.05 groups. Histological assessments showed a thicker and more trabecular bone around the implant sockets in the PTH2 specimens than in the PTH1 and control specimens. The bone area around the implant socket was significantly greater in the PTH2 group than in the PTH1 and control groups (p<0.05. Conclusions: Our results suggest that continual intermittent PTH administration before and after dental implant placement is effective for the achievement of favorable stability and osseointegration in the presence of

  10. Oral and masticatory rehabilitation using osseointegrated dental implants after resective treatment of multicystic ameloblastoma in the lower jaw with a fibula graft

    Directory of Open Access Journals (Sweden)

    João Ricardo Almeida Grossi

    2018-01-01

    Full Text Available Ameloblastoma is an aggressive odontogenic tumor which typically occurs between third and fourth decade of life that often needs resective approach. Immediate reconstruction may show better results. The treatment of multicystic ameloblastoma in the mandible being a rare case that occurred in the late second decade of life, which was surgically removed along with the affected teeth with safety margins, and the region was immediately reconstructed using a vascularized graft, removed from the fibula. Its integration, in combination with osseointegrated dental implants and fixed implant-supported prostheses, restored chewing function and esthetics. After 6 years from fibular graft and 24 months of dental implants, an excellent outcome was observed, with oral health and normal functions properly restored, and the immediate reconstruction of the mandible in resective cases, associated with oral rehabilitation with dental implants, may be considered a suitable treatment option.

  11. Dental Implant Surrounding Marginal Bone Level Evaluation: Platform Switching versus Platform Matching—One-Year Retrospective Study

    Directory of Open Access Journals (Sweden)

    Eisner Salamanca

    2017-01-01

    Full Text Available The benefits and feasibility of platform switching have been discussed in several studies, reporting lesser crestal bone loss in platform-switched implants than in platform-matched implants. Objective. The aim of the present study was to observe the changes in vertical and horizontal marginal bone levels in platform-switched and platform-matched dental implants. Materials and Methods. 51 patients received 60 dental implants in the present study over a 1-year period. Measurement was performed between the implant shoulder and the most apical and horizontal marginal defect by periapical radiographs to examine the changes of peri-implant alveolar bone before and 12 months after prosthodontic restoration delivery. Results. These marginal bone measurements showed a bone gain of 0.23±0.58 mm in the vertical gap and 0.22±0.53 mm in the horizontal gap of platform matching, while in platform switching a bone gain of 0.93±1 mm (P<0.05 in the vertical gap and 0.50±0.56 mm in the horizontal gap was found. The average vertical gap reduction from the baseline until 12 months was 0.92±1.11 mm in platform switching and 0.29±0.85 mm in platform matching (P<0.05. Conclusions. Within the limitations of the present study, platform switching seemed to be more effective for a better peri-implant alveolar bone vertical and horizontal gap reduction at 1 year.

  12. Comparison of clinical and radiographic status around dental implants placed in patients with and without prediabetes: 1-year follow-up outcomes.

    Science.gov (United States)

    Al Amri, Mohammad D; Abduljabbar, Tariq S; Al-Kheraif, Abdulaziz A; Romanos, Georgios E; Javed, Fawad

    2017-02-01

    We hypothesized that peri-implant soft tissue inflammation is worse and peri-implant marginal bone loss (MBL) is higher around dental implants placed in patients with prediabetes compared to healthy subjects. The aim of the present 12-month follow-up study was to compare the clinical and radiographic status around dental implants placed in patients with and without prediabetes. Twelve patients with medically diagnosed prediabetes (Group-1) and 12 controls (Group-2) were included. All patients were indicated for single tooth maxillary or mandibular premolar replacement with the adjacent teeth intact. Success of the restored implants was assessed by comparing clinical (peri-implant bleeding on probing [BOP], and probing pocket depth [PPD]) and radiographic (peri-implant MBL) parameters at baseline and at 12-months follow-up. Statistical analysis was performed using one-way analysis of variance, and P-values implant pockets with PPD ≥ 4 mm in both groups. At 12-month follow-up, the mean MBL among implants placed in groups 1 and 2 were 0.2 ± 0.1 mm and 0.1 ± 0.01 mm, respectively. Overall, the periodontal status (PI, BOP and PPD ≥ 4 mm) at 12-month follow-up was comparable among patients in both groups. Within the limitations of this study, it is concluded that dental implants inserted in prediabetic and healthy patients have similar success rates and remain clinically and radiographically stable after 1-year follow-up. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Application of high resolution synchrotron micro-CT radiation in dental implant osseointegration.

    Science.gov (United States)

    Neldam, Camilla Albeck; Lauridsen, Torsten; Rack, Alexander; Lefolii, Tore Tranberg; Jørgensen, Niklas Rye; Feidenhans'l, Robert; Pinholt, Else Marie

    2015-06-01

    The purpose of this study was to describe a refined method using high-resolution synchrotron radiation microtomography (SRmicro-CT) to evaluate osseointegration and peri-implant bone volume fraction after titanium dental implant insertion. SRmicro-CT is considered gold standard evaluating bone microarchitecture. Its high resolution, high contrast, and excellent high signal-to-noise-ratio all contribute to the highest spatial resolutions achievable today. Using SRmicro-CT at a voxel size of 5 μm in an experimental goat mandible model, the peri-implant bone volume fraction was found to quickly increase to 50% as the radial distance from the implant surface increased, and levelled out to approximately 80% at a distance of 400 μm. This method has been successful in depicting the bone and cavities in three dimensions thereby enabling us to give a more precise answer to the fraction of the bone-to-implant contact compared to previous methods. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Osseointegration of a 3D Printed Stemmed Titanium Dental Implant: A Pilot Study

    Directory of Open Access Journals (Sweden)

    James Tedesco

    2017-01-01

    Full Text Available In this pilot study, a 3D printed Grade V titanium dental implant with a novel dual-stemmed design was investigated for its biocompatibility in vivo. Both dual-stemmed (n = 12 and conventional stainless steel conical (n = 4 implants were inserted into the tibial metaphysis of New Zealand white rabbits for 3 and 12 weeks and then retrieved with the surrounding bone, fixed, dehydrated, and embedded into epoxy resin. The implants were analyzed using correlative histology, microcomputed tomography, scanning electron microscopy (SEM, and transmission electron microscopy (TEM. The histological presence of multinucleated osteoclasts and cuboidal osteoblasts revealed active bone remodeling in the stemmed implant starting at 3 weeks and by 12 weeks in the conventional implant. Bone-implant contact values indicated that the stemmed implants supported bone growth along the implant from the coronal crest at both 3- and 12-week time periods and showed bone growth into microporosities of the 3D printed surface after 12 weeks. In some cases, new bone formation was noted in between the stems of the device. Conventional implants showed mechanical interlocking but did have indications of stress cracking and bone debris. This study demonstrates the comparable biocompatibility of these 3D printed stemmed implants in rabbits up to 12 weeks.

  15. Osseointegration of a 3D Printed Stemmed Titanium Dental Implant: A Pilot Study.

    Science.gov (United States)

    Tedesco, James; Lee, Bryan E J; Lin, Alex Y W; Binkley, Dakota M; Delaney, Kathleen H; Kwiecien, Jacek M; Grandfield, Kathryn

    2017-01-01

    In this pilot study, a 3D printed Grade V titanium dental implant with a novel dual-stemmed design was investigated for its biocompatibility in vivo. Both dual-stemmed ( n  = 12) and conventional stainless steel conical ( n  = 4) implants were inserted into the tibial metaphysis of New Zealand white rabbits for 3 and 12 weeks and then retrieved with the surrounding bone, fixed, dehydrated, and embedded into epoxy resin. The implants were analyzed using correlative histology, microcomputed tomography, scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The histological presence of multinucleated osteoclasts and cuboidal osteoblasts revealed active bone remodeling in the stemmed implant starting at 3 weeks and by 12 weeks in the conventional implant. Bone-implant contact values indicated that the stemmed implants supported bone growth along the implant from the coronal crest at both 3- and 12-week time periods and showed bone growth into microporosities of the 3D printed surface after 12 weeks. In some cases, new bone formation was noted in between the stems of the device. Conventional implants showed mechanical interlocking but did have indications of stress cracking and bone debris. This study demonstrates the comparable biocompatibility of these 3D printed stemmed implants in rabbits up to 12 weeks.

  16. Bone Response to Two Dental Implants with Different Sandblasted/Acid-Etched Implant Surfaces: A Histological and Histomorphometrical Study in Rabbits

    Directory of Open Access Journals (Sweden)

    Antonio Scarano

    2017-01-01

    Full Text Available Background. Scientific evidence in the field of implant dentistry of the past 20 years established that titanium rough surfaces have shown improved osseointegration rates. In a majority of dental implants, the surface microroughness was obtained by grit blasting and/or acid etching. The aim of the study was to evaluate in vivo two different highly hydrophilic surfaces at different experimental times. Methods. Calcium-modified (CA and SLActive surfaces were evaluated and a total of 18 implants for each type of surface were positioned into the rabbit articular femoral knee-joint in a split model experiment, and they were evaluated histologically and histomorphometrically at 15, 30, and 60 days of healing. Results. Bone-implant contact (BIC at the two-implant surfaces was significantly different in favor of the CA surface at 15 days (p=0.027, while SLActive displayed not significantly higher values at 30 (p=0.51 and 60 days (p=0.061. Conclusion. Both implant surfaces show an intimate interaction with newly formed bone.

  17. Osteonecrosis of the jaw after dental implant placement. A case report

    Directory of Open Access Journals (Sweden)

    J.L. Calvo-Guirado

    2014-03-01

    Full Text Available Background: In the past few years, the occurrence of an oral lesion, called osteonecrosis of the jaw, has increasingly been reported in patients undergoing treatment with systemic bisphosphonates (BPs; however, few papers dealing with oral biphosphonates related osteonecrosis of the jaws (BRONJ can be found in the literature. The purpose of the present case was to report an occurrence of BRONJ after implant insertion. Case report: Ten years ago, eight dental implants were inserted in the jaw of a 65-year-old female. After 5 years of treatment with alendronic acid, a breakdown of the oral mucosa covering the implants occurred with a purulent discharge in the left side of the jaw; periapical radiolucency was present around both distal implants. An en-block resection of the alveolar bone including the two implants was performed. Thirthy-five hyperbaric sessions were taken and no signs of recurrence of the lesion were observed after a follow-up of 20 months. Before the new implant insertion, the patient had suspended the treatment with alendronic acid for 6 months. At the interface of one of the implants, a gap was observed between bone and implant. This bone was non vital, and many osteocyte lacunae were empty. Moreover, this bone appeared to be partially demineralized. Conclusion: There is certainly a temporal association between oral BPs use and development of BRONJ, but a correlation does not necessarily mean causation. In patients undergoing oraltreatment, clinicians must be aware of the increased risk of implant failure.

  18. Gallium and silicon synergistically promote osseointegration of dental implant in patients with osteoporosis.

    Science.gov (United States)

    Liu, Jinsong; Wu, Zuosu; He, Hongli; Cai, Kaiyong; Zhang, Hualin; Xu, Lihua

    2017-06-01

    Over the last few decades, a wide variety of dental implants have been successfully placed in jaw bones to restore tooth function. But major challenges still remain in patients with osteoporosis involving compromised osseointegration, and the therapeutic methods is far from optimism. Gallium can directly inhibit bone osteolysis, prevent bone calcium release and augment bone mass, which makes Ga unique among the potential antiresorptive drugs. Silicon, as an indispensable modulator in bone formation, presents its bone anabolic effects, while reduces, at least doesn't increase, bone resorption. We hypothesize that the combination of bone anabolic effects of Si and antiresorptive effects of Ga will result in synergistic effects on the improvement of osteointegration under osteoporotic condition. In our strategy, in order to maximize the efficacy while minimize the side effects of ions, a novel titania mesoporous layer fabricated by electrochemical anodization on the surface of titanium implant will be employed as a promising local drug delivery system. The synergistic effects of Ga and Si on improving osseointegration will be verified by animal experiments, and be furthered by clinical trials. Our hypothesis could help to create an option to improve success rate of dental implants in osteoporotic patients. Copyright © 2017. Published by Elsevier Ltd.

  19. Extracellular DNA Contributes to Dental Biofilm Stability

    DEFF Research Database (Denmark)

    Schlafer, Sebastian; Meyer, Rikke Louise; Dige, Irene

    2017-01-01

    dental biofilms. This study aimed to determine whether eDNA was part of the matrix in biofilms grown in situ in the absence of sucrose and whether treatment with DNase dispersed biofilms grown for 2.5, 5, 7.5, 16.5, or 24 h. Three hundred biofilms from 10 study participants were collected and treated...... the amount of biofilm in very early stages of growth (up to 7.5 h), but the treatment effect decreased with increasing biofilm age. This study proves the involvement of eDNA in dental biofilm formation and its importance for biofilm stability in the earliest stages. Further research is required to uncover...

  20. Transcription factor and bone marrow stromal cells in osseointegration of dental implants

    Directory of Open Access Journals (Sweden)

    SG Yan

    2018-05-01

    Full Text Available Titanium implants are widely used in dental clinics and orthopaedic surgery. However, bone formation surrounding the implant is relatively slow after inserting the implant. The current study assessed the effects of bone marrow stromal cells (BMSCs with forced expression of special AT-rich sequence-binding protein 2 (SATB2 on the osseointegration of titanium implants. To determine whether SATB2 overexpression in BMSCs can enhance the osseointegration of implants, BMSCs were infected with the retrovirus encoding Satb2 (pBABE-Satb2 and were locally applied to bone defects before implanting the titanium implants in the mouse femur. Seven and twenty-one days after implantation, the femora were isolated for immunohistochemical (IHC staining, haematoxylin eosin (H&E staining, real-time quantitative reverse transcription polymerase chain reaction (qRT-PCR, and micro-computed tomography (μCT analysis. IHC staining analysis revealed that SATB2-overexpressing BMSCs were intensely distributed in the bone tissue surrounding the implant. Histological analysis showed that SATB2-overexpressing BMSCs significantly enhanced new bone formation and bone-to-implant contact 3 weeks after implantation. Real-time qRT-PCR results showed that the local delivery of SATB2-overexpressing BMSCs enhanced expression levels of potent osteogenic transcription factors and bone matrix proteins in the implantation sites. μCT analysis demonstrated that SATB2-overexpressing BMSCs significantly increased the density of the newly formed bone surrounding the implant 3 weeks post-operatively. These results conclude that local delivery of SATB2-overexpressing BMSCs significantly accelerates osseointegration of titanium implants. These results provide support for future pharmacological and clinical applications of SATB2, which accelerates bone regeneration around titanium implants.

  1. To reduce the maximum stress and the stress shielding effect around a dental implant-bone interface using radial functionally graded biomaterials.

    Science.gov (United States)

    Asgharzadeh Shirazi, H; Ayatollahi, M R; Asnafi, A

    2017-05-01

    In a dental implant system, the value of stress and its distribution plays a pivotal role on the strength, durability and life of the implant-bone system. A typical implant consists of a Titanium core and a thin layer of biocompatible material such as the hydroxyapatite. This coating has a wide range of clinical applications in orthopedics and dentistry due to its biocompatibility and bioactivity characteristics. Low bonding strength and sudden variation of mechanical properties between the coating and the metallic layers are the main disadvantages of such common implants. To overcome these problems, a radial distributed functionally graded biomaterial (FGBM) was proposed in this paper and the effect of material property on the stress distribution around the dental implant-bone interface was studied. A three-dimensional finite element simulation was used to illustrate how the use of radial FGBM dental implant can reduce the maximum von Mises stress and, also the stress shielding effect in both the cortical and cancellous bones. The results, of course, give anybody an idea about optimized behaviors that can be achieved using such materials. The finite element solver was validated by familiar methods and the results were compared to previous works in the literature.

  2. Elements of implant-supported rehabilitation planning in patients with bruxism.

    Science.gov (United States)

    Sarmento, Hugo Ramalho; Dantas, Raquel Venâncio Fernandes; Pereira-Cenci, Tatiana; Faot, Fernanda

    2012-11-01

    The rehabilitation of partial or completely edentulous patients with implant-supported prostheses has been widely used, achieving high success rates. However, many studies consider the presence of bruxism as a contraindication for this treatment modality. The purpose of this study was to revise the literature and identify risk factors in implant-supported rehabilitation planning in subjects with bruxism. Available literature was searched through Medline, with no time limit, including only studies in English. Topics discussed were etiology of bruxism and its implications on dental implants, biomechanical considerations regarding the overload on dental implants, and methods to prevent the occurrence of overloads in implant-supported prostheses. The rehabilitation of bruxers using implant-supported prostheses, using implants with adequate length and diameter, as well as proper positioning seems to be a reliable treatment, with reduced risks of failure. Bruxism control through the use of a nightguard by rigid occlusal stabilization appliance relieved in the region of implants is highly indicated. Although it is clear that implant-supported rehabilitation of patients with bruxism requires adequate planning and follow-up, well-designed randomized controlled trials are needed to provide reliable evidence on the long-term success of this treatment modality.

  3. A radiographic study on the prevalence of knife-edge residual alveolar ridge at proposed dental implant sites

    International Nuclear Information System (INIS)

    AlFaleh, Wafaa

    2009-01-01

    Dental implants are widely used in restoration of completely or partially edentulous dental arches. Before placement of endosseous implants in the jaws, both the quantity and quality of the residual ridge must be assessed radiographically. Remodeling activity after tooth extraction is localized primarily at the crestal area of the residual ridges, resulting in reduction of the height of bone and creation of various three-dimensional shapes of the residual ridges. When bone resorption at the lingual and buccal aspects is greater than that at the crestal area, a knife-edge type of residual ridge develops. The aim of this study was to evaluate the prevalence of the knife-edge morphology of the residual alveolar bone at proposed implant sites in partially or completely edentulous patients. Computed tomography (CT) cross-sectional images of the upper and lower jaws were assessed at the proposed sites before implant placement. Images of 258 proposed implant sites belonging to 30 patients were assessed radiographically. In 120 proposed implant sites out of 258 (46.5%), the residual alveolar ridge had a knife-edge configuration, the majority belonging to completely edentulous patients who lost their teeth more than ten years previously. High prevalence of knife-edge ridge was found, therefore, replacement of missing teeth by immediate implant is recommended to prevent atrophy or knife-edge morphology of the residual ridge. (author)

  4. Comparison of the fracture resistance of dental implants with different abutment taper angles.

    Science.gov (United States)

    Wang, Kun; Geng, Jianping; Jones, David; Xu, Wei

    2016-06-01

    To investigate the effects of abutment taper angles on the fracture strength of dental implants with TIS (taper integrated screwed-in) connection. Thirty prototype cylindrical titanium alloy 5.0mm-diameter dental implants with different TIS-connection designs were divided into six groups and tested for their fracture strength, using a universal testing machine. These groups consisted of combinations of 3.5 and 4.0 mm abutment diameter, each with taper angles of 6°, 8° or 10°. 3-Dimensional finite element analysis (FEA) was also used to analyze stress states at implant-abutment connection areas. In general, the mechanical tests found an increasing trend of implant fracture forces as the taper angle enlarged. When the abutment diameter was 3.5 mm, the mean fracture forces for 8° and 10° taper groups were 1638.9 N ± 20.3 and 1577.1 N ± 103.2, respectively, both larger than that for the 6° taper group of 1475.0 N ± 24.4, with the largest increasing rate of 11.1%. Furthermore, the difference between 8° and 6° taper groups was significant, based on Tamhane's multiple comparison test (Pabutment groups, as the taper angle was enlarged from 6° to 8° and 10°, the mean fracture value was increased from 1066.7 N ± 56.1 to 1241.4 N ± 6.4 and 1419.3 N ± 20.0, with the largest increasing rate of 33.1%, and the differences among the three groups were significant (Pabutment taper angles and supported the findings of the static tests. In conclusion, increases of the abutment taper angle could significantly increase implant fracture resistance in most cases established in the study, which is due to the increased implant wall thickness in the connection part resulting from the taper angle enlargement. The increasing effects were notable when a thin implant wall was present to accommodate wide abutments. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Is bruxism a risk factor for dental implants? A systematic review of the literature

    NARCIS (Netherlands)

    Manfredini, D.; Poggio, C.E.; Lobbezoo, F.

    2014-01-01

    Purpose To systematically review the literature on the role of bruxism as a risk factor for the different complications on dental implant-supported rehabilitations. Material and Methods A systematic search in the National Library of Medicine's Medline Database was performed to identify all

  6. Role of clinician's experience and implant design on implant stability. An ex vivo study in artificial soft bones.

    Science.gov (United States)

    Romanos, Georgios E; Basha-Hijazi, Abdulaziz; Gupta, Bhumija; Ren, Yan-Fang; Malmstrom, Hans

    2014-04-01

    Clinical experience in implant placement is important in order to prevent implant failures. However, the implant design affects the primary implant stability (PS) especially in poor quality bones. Therefore, the aim of this study was to compare the effect of clinician surgical experience on PS, when placing different type of implant designs. A total of 180 implants (90 parallel walled-P and 90 tapered-T) were placed in freshly slaughtered cow ribs. Bone quality was evaluated by two examiners during surgery and considered as 'type IV' bone. Implants (ø 5 mm, length: 15 mm, Osseotite, BIOMET 3i, Palm Beach Gardens, FL, USA) were placed by three different clinicians (master/I, good/II, non-experienced/III, under direct supervision of a manufacturer representative; 30 implants/group). An independent observer assessed the accuracy of placement by resonance frequency analysis (RFA) with implant stability quotient (ISQ) values. Two-way analysis of variance (ANOVA) and Tukey's post hoc test were used to detect the surgical experience of the clinicians and their interaction and effects of implant design on the PS. All implants were mechanically stable. The mean ISQ values were: 49.57(± 18.49) for the P-implants and 67.07(± 8.79) for the T-implants. The two-way ANOVA showed significant effects of implant design (p bone. © 2012 Wiley Periodicals, Inc.

  7. Clinico-statistical study on the patients who were applied preoperative CT imaging for dental implant treatment in Iwate Medical University Hospital

    International Nuclear Information System (INIS)

    Shoji, Satoru; Izumisawa, Mitsuru; Satoh, Hitoshi; Hoshino, Masayuki; Takahashi, Noriaki; Shozushima, Masanori; Nakasato, Tatsuhiko

    2007-01-01

    The diagnosis of jaw bones using X-ray computed tomography (CT) is important to determine placement of dental implants. A Clinico-statistical study were made on 490 cases which applied preoperative dental mutiplannar reconstructing CT (dental MPR) imaging for dental implant treatment in Iwate Medical University Hospital, during a five-year period from 2002 to 2006. The following results were obtained: The 490 cases consisted of 179 males and 311 females. They ranged in age from 16 to 80 years, the average age was 53.6 years old. The largest number of cases were in their 50's and, in most generations, there were more female cases than male. Similar cases have been increasing every year. Most patients were referred from other clinics to our hospital. Of the cases that underwent CT scanning more were mandible than maxilla. Implantation prearranged region revealed a predominance of mandible in anterior teeth, and maxilla in molar teeth. The cases that were using diagnostic surgical stents increased in the first three years, but were constant afterwards. (author)

  8. Antimicrobial effect of proteflazid extract on microflora of peri-implant areas in infectious and inflammatory complications after dental implantation

    Directory of Open Access Journals (Sweden)

    M. M. Ananieva

    2017-12-01

    Full Text Available The purpose of this study was to investigate the proteflazid extraction antimicrobial action onto causative agents of infectious and inflammatory diseases occurring during dental implant placement. Materials and Methods. We studied clinical strains of Streptococcus sanguinis, Staphylococcus warneri and Kocuria kristinae, isolated from oral mucosa of patients who were diagnosed with peri-implant mucositis and peri-implantitis. The cultivation of strains was carried out by standard method. Final identification was carried out with an automatic bacteriological analyzer Viteck 2 compact bioMérieux (France according to manufacturer's instructions. The sensitivity of derived strains to proteflazid and to 96 % ethyl alcohol assessment was done by double serial dilutions according to the standard procedure. Results. The clinical strains of Streptococcus sanguinis, Staphylococcus warneri and Kocuria kristinae were found to be sensitive to effects of proteflazid extract. K. kristinae was proven to be the least susceptible strain. But the clinical strain of Streptococcus sanguinis was found to be the most sensitive to proteflazid extract. 96 % ethyl alcohol, which is a component of the extract, showed a bactericidal effect on the clinical strains in the study, but its minimal bactericidal concentration was significantly lower than minimal bactericidal concentration of the proteflazid extract. Conclusions. The proteflazid extract can produce antimicrobial effect on the clinical strains of Streptococcus sanguinis, Staphylococcus warneri and Kocuria kristinae, which colonize the oral mucosa of patients with infectious and inflammatory complications following dental implant placement. Antimicrobial action of the proteflazid extract is much higher than action of 96% ethyl alcohol that confirms the direct antimicrobial action of flavonoids, which are components of the studied extract.

  9. Dental Implant Placement with Simultaneous Anterior Maxillary Reconstruction with Block and Particulate Fresh Frozen Allograft Bone: A Case Report with 24-Month Follow-Up Data

    Directory of Open Access Journals (Sweden)

    J. S. Vieira

    2017-01-01

    Full Text Available Fresh frozen allograft bone is routinely used in orthopedic surgery for the reconstruction of large bone defects, and its use in oral and maxillofacial surgery is increasing. The purpose of this case was to demonstrate the installation of dental implants and the use of fresh frozen bone for reconstruction of anterior maxilla in the same surgery. This case report presents the insertion of dental implants followed immediately by a placement of fresh frozen allograft in block and particle for a reconstruction of atrophic anterior maxillary in the same surgery. Ten months subsequent to this procedure, provisional fixed prosthesis was installed on the implants. Four months later (postoperative month 14, the final fixed prosthesis was installed and the clinical success was observed. The insertion of dental implants followed immediately by a placement of fresh frozen allograft is a safe and efficient process that results in the successful return of dental function and aesthetic rehabilitation for the patient.

  10. In vitro bioactivity test of real dental implants according to ISO 23317

    Czech Academy of Sciences Publication Activity Database

    Kolafová, M.; Št’ovíček, J.; Strnad, J.; Zemek, Josef; Dybal, Jiří

    2017-01-01

    Roč. 32, č. 6 (2017), s. 1221-1230 ISSN 0882-2786 Institutional support: RVO:68378271 ; RVO:61389013 Keywords : dental implants * n vitro bioactivity * ISO 23317 * SBF * surface treatment Subject RIV: BM - Solid Matter Physics ; Magnetism; CD - Macromolecular Chemistry (UMCH-V) OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.); Polymer science (UMCH-V) Impact factor: 2.263, year: 2016

  11. Changes in the fractal dimension, feret diameter, and lacunarity of mandibular alveolar bone during initial healing of dental implants.

    Science.gov (United States)

    Önem, Erinç; Baksı, B Güniz; Sogur, Elif

    2012-01-01

    To evaluate the combination of fractal dimension (FD), lacunarity, and Feret diameter (FeD) to quantitatively characterize structural changes of mandibular alveolar bone around dental implants during initial healing. Three standard-sized regions of interest (ROIs) (mesial and distal crest and apical area) around implants and three ROIs of the same size in the alveolar bone on the contralateral side were analyzed on digital panoramic images. FD was calculated using the box-counting method, and lacunarity was calculated using the FracLac plugin of Image J software. FeD was measured in the same ROIs. Comparisons of the groups were done with the Dunnett test. Forty-two implants in the posterior mandibles of 21 patients were used for FD measurements. A total of 189 ROIs was segmented into binary images. Mean FD values for mesial, distal, and apical ROIs around implants were 1.26, 1.36, and 1.4, respectively. The mean FD of alveolar bone around premolars/molars was 1.39 for all ROIs. The mean FeD for mesial, distal, and apical ROIs around implants was 7.63, 7.86, and 8.02, respectively, whereas it ranged between 7.88 and 8.13 for premolar teeth. Mean lacunarity values for mesial, distal, and apical ROIs around implants were 0.53, 0.51, and 0.48, respectively. Lacunarity values for ROIs around premolars ranged between 0.45 and 0.50. No significant differences were observed in FD, FeD, or lacunarity measurements between ROIs around implants and around teeth. The satisfactory healing of bone following implant placement may be monitored by calculating FD, lacunarity, and FeD using digital panoramic images. Although preliminary, these values may alert the practitioner to any implants with loss of stability.

  12. A Novel Surgical Template Design in Staged Dental Implant Rehabilitations

    Directory of Open Access Journals (Sweden)

    Michael Patras

    2012-05-01

    Full Text Available Background: The philosophy of a gradual transition to an implant retained prosthesis in cases of full-mouth or extensive rehabilitation usually involves a staged treatment concept. In this therapeutic approach, the placement of implants may sometimes be divided into phases. During a subsequent surgical phase of treatment, the pre-existing implants can serve as anchors for the surgical template. Those modified surgical templates help in the precise transferring of restorative information into the surgical field and guide the optimal three-dimensional implant positioning. Methods: This article highlights the rationale of implant-retained surgical templates and illustrates them through the presentation of two clinical cases. The templates are duplicates of the provisional restorations and are secured to the existing implants through the utilization of implant mounts. Results: This template design in such staged procedures provided stability in the surgical field and enhanced the accuracy in implant positioning based upon the planned restoration, thus ensuring predictable treatment outcomes.Conclusions: Successful rehabilitation lies in the correct sequence of surgical and prosthetic procedures. Whenever a staged approach of implant placement is planned, the clinician can effectively use the initially placed implants as anchors for the surgical template during the second phase of implant surgery.

  13. Guided tissue regeneration ensures osseointegration of dental implants placed into extraction sockets. An experimental study in monkeys

    DEFF Research Database (Denmark)

    Warrer, L; Gotfredsen, K; Hjørting-Hansen, E

    1991-01-01

    on the buccal and palatal aspects of the maxillary molars in both sides of the jaw. The second molars were then extracted and self tapping titanium implants of the screw type (Astra Dental Implants) were inserted into the sockets of the largest roots. In the coronal portion of the sockets, a void was always...... present between the implant and the socket walls. In one side of the jaw, a membrane (Gore-Tex Augmentation Material) was adjusted to cover the implant. The implant in the other side of the jaw served as control and was only covered by the tissue flaps. Microscopic analysis after 3 months of healing...... technique can secure complete osseointegration of implants inserted immediately into extraction sockets....

  14. Implantation and Stability of Metallic Fiducials Within Pulmonary Lesions

    International Nuclear Information System (INIS)

    Kupelian, Patrick A.; Forbes, Alan; Willoughby, Twyla R. M.S.; Wallace, Karen; Manon, Rafael R.; Meeks, Sanford L.; Herrera, Luis; Johnston, Alan; Herran, Juan J.

    2007-01-01

    Purpose: To report and describe implantation techniques and stability of metallic fiducials in lung lesions to be treated with external beam radiotherapy. Methods and Materials: Patients undergoing radiation therapy for small early-stage lung cancer underwent implantation with small metallic markers. Implantation was either transcutaneous under computed tomographic (CT) or fluoroscopic guidance or transbronchial with the superDimension/Bronchus system (radiofrequency signal-based bronchoscopy guidance related to CT images). Results: Implantation was performed transcutaneously in 15 patients and transbronchially in 8 patients. Pneumothorax occurred with eight of the 15 transcutaneous implants, six of which required chest tube placement. None of the patients who underwent transbronchial implantation developed pneumothorax. Successfully inserted markers were all usable during gated image-guided radiotherapy. Marker stability was determined by observing the variation in gross target volume (GTV) centroid relative to the marker on repeated CT scans. Average three-dimensional variation in the GTV center relative to the marker was 2.6 ± 1.3 (SD) mm, and the largest variation along any anatomic axis for any patient was <5 mm. Average GTV volume decrease during the observation period was 34% ± 23%. Gross tumor volumes do not appear to shrink uniformly about the center of the tumor, but rather the tumor shapes deform substantially throughout treatment. Conclusions: Transbronchial marker placement is less invasive than transcutaneous placement, which is associated with high pneumothorax rates. Although marker geometry can be affected by tumor shrinkage, implanted markers are stable within tumors throughout the treatment duration regardless of implantation method

  15. Immediately loaded zygomatic implants vs conventional dental implants in augmented atrophic maxillae: 4 months post-loading results from a multicentre randomised controlled trial.

    Science.gov (United States)

    Esposito, Marco; Davó, Rubén; Marti-Pages, Carlos; Ferrer-Fuertes, Ada; Barausse, Carlo; Pistilli, Roberto; Ippolito, Daniela Rita; Felice, Pietro

    2018-01-01

    To compare the clinical outcome of immediately loaded cross-arch maxillary prostheses supported by zygomatic implants vs conventional implants placed in augmented bone. A total of 71 edentulous patients with severely atrophic maxillas, who did not have sufficient bone volume to place dental implants or when it was possible to place only two implants in the front area (minimal diameter 3.5 mm and length of 8 mm) and less than 4.0 mm of bone height subantrally, were randomised according to a parallel group design. They (35 patients) received zygomatic implants to be loaded immediately vs grafting with a xenograft, followed, after 6 months of graft consolidation, by the placement of six to eight conventional dental implants, submerged for 4 months (36 patients). To be loaded immediately, zygomatic implants had to be inserted with an insertion torque superior to 40 Ncm. Screw-retained, metal-reinforced, acrylic provisional prostheses were provided to be replaced by definitive Procera Implant Bridge Titanium prostheses (Nobel Biocare, Göteborg, Sweden) with ceramic or acrylic veneer materials 4 months after initial loading. Outcome measures were: prosthesis, implant and augmentation failures, any complications, quality of life (OHIP-14), the number of days that patients experienced total or partial impaired activity, time to function, and number of dental visits, assessed by independent assessors. Patients were followed up to 4 months after loading. No augmentation procedure failed. Three patients dropped out from the augmentation group. Six prostheses could not be delivered or failed in the augmentation group vs one prosthesis in the zygomatic group, the difference being statistically significant (difference in proportions = 15.32%; P = 0.04; 95% CI: 0.23 to 31.7). Eight patients lost 35 implants in the augmentation group vs three implants in one patient from the zygomatic group, the difference being statistically significant (difference in proportions = 21.38%; P = 0

  16. Dental implants inserted in fresh extraction sockets versus healed sites: a systematic review and meta-analysis.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Albrektsson, Tomas; Wennerberg, Ann

    2015-01-01

    To test the null hypothesis of no difference in the implant failure rates, postoperative infection and marginal bone loss for the insertion of dental implants in fresh extraction sockets compared to the insertion in healed sites, against the alternative hypothesis of a difference. Main search terms used in combination: dental implant, oral implant, resh extraction socket, immediate placement, immediate insertion, immediate implant. An electronic search was undertaken in July/2014, in PubMed, Web of Science, Cochrane Oral Health Group Trials Register plus hand-searching. Eligibility criteria included clinical human studies, either randomized or not. The search strategy resulted in 73 publications, with 8,241 implants inserted in sockets (330 failures, 4.00%), and 19,410 in healed sites (599 failures, 3.09%). It is suggested that the insertion of implants in fresh extraction sockets affects the failure rates (RR 1.58, 95% CI 1.27-1.95, P<0.0001). The difference was not statistically significant when studies evaluating implants inserted in maxillae or in mandibles were pooled, or when the studies using implants to rehabilitate patients with full-arch prostheses were pooled; however, it was significant for the studies that rehabilitated patients with implant-supported single crowns and for the controlled studies. There was no apparent significant effect on the occurrence of postoperative infection or on the magnitude of marginal bone loss. The results should be interpreted with caution due to the potential for biases and to the presence of uncontrolled confounding factors in the included studies, most of them not randomized. The question whether immediate implants are more at risk for failure than implants placed in mature bone has received increasing attention in the last years. As the philosophies of treatment alter over time, a periodic review of the different concepts is necessary to refine techniques and eliminate unnecessary procedures. This would form a basis

  17. The importance of dental CT for implantation in mouth, jaw, and face surgery

    International Nuclear Information System (INIS)

    Widlitzek, H.; Koenig, S.; Golin, U.

    1996-01-01

    The importance of dental CT in comparison to conventional OPT in implantation diagnostics is demonstrated in specific indication groups (atrophy of upper and lower jaw, patient after tumor and reconstructive surgery). The application of radiological techniques is illustrated in relation to diagnostic information quality, radiation exposure and cost effectiveness regarding clinical routine use. (orig.) [de

  18. Hydrothermal treatment for TiN as abrasion resistant dental implant coating and its fibroblast response

    International Nuclear Information System (INIS)

    Shi, Xingling; Xu, Lingli; Munar, Melvin L.; Ishikawa, Kunio

    2015-01-01

    Dental implant made of pure titanium (Ti) is prone to scratch and abrasion during routine oral hygiene procedures. This results an increase in surface roughness and therefore, facilitates the adhesion of bacteria. In severe cases, this could lead to peri-implantitis. To overcome this problem, surface modification of Ti is necessary to improve its abrasion resistance. Besides, a strong implant–gingiva interface should also be guaranteed to prevent the adhesion of bacteria. In this study, titanium nitride (TiN) coating was first prepared with gas nitriding to increase surface hardness of pure the substrate. Then, the TiN was hydrothermally treated in CaCl 2 solution in order to improve its soft tissue biocompatibility. The effect of hydrothermal treatment temperature on surface properties of TiN was investigated and its biocompatibility was assessed in vitro using NIH3T3 fibroblast cell. It was determined that 120 °C was the critical temperature for the hydrothermal treatment condition. Treatment below 120 °C could incorporate Ca into TiN surface, oxidize TiN surface partially and then improve the wettability while preserving its morphology and hardness. Fibroblast cell attachment and proliferation were improved and cell spreading was enhanced on hydrothermally treated specimens compared with untreated ones. Improved wettability, Ca incorporation and negative surface due to interstitial N were believed to be the main reasons. Hydrothermal treatment is expected to make TiN a promising dental implant coating with excellent abrasion resistance and good soft tissue affinity. - Highlights: • Ca was incorporated into TiN surface while not sacrificing its hardness. • Interstitial N due to oxidation promoted Ca adsorption and cell adhesion. • Hydrothermal treatment makes TiN a promising coating for dental implant

  19. Hydrothermal treatment for TiN as abrasion resistant dental implant coating and its fibroblast response

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Xingling, E-mail: shixingling1985@hotmail.com [School of Material Science and Engineering, Jiangsu University of Science and Technology, Zhenjiang 212003 (China); Department of Biomaterials, Faculty of Dental Science, Kyushu University, Fukuoka 812-8582 (Japan); Jiangsu Provincial Key Laboratory for Interventional Medical Devices, Huaiyin Institute of Technology, Huaian 223003 (China); Xu, Lingli [School of Material Science and Engineering, Jiangsu University of Science and Technology, Zhenjiang 212003 (China); Munar, Melvin L.; Ishikawa, Kunio [Department of Biomaterials, Faculty of Dental Science, Kyushu University, Fukuoka 812-8582 (Japan)

    2015-04-01

    Dental implant made of pure titanium (Ti) is prone to scratch and abrasion during routine oral hygiene procedures. This results an increase in surface roughness and therefore, facilitates the adhesion of bacteria. In severe cases, this could lead to peri-implantitis. To overcome this problem, surface modification of Ti is necessary to improve its abrasion resistance. Besides, a strong implant–gingiva interface should also be guaranteed to prevent the adhesion of bacteria. In this study, titanium nitride (TiN) coating was first prepared with gas nitriding to increase surface hardness of pure the substrate. Then, the TiN was hydrothermally treated in CaCl{sub 2} solution in order to improve its soft tissue biocompatibility. The effect of hydrothermal treatment temperature on surface properties of TiN was investigated and its biocompatibility was assessed in vitro using NIH3T3 fibroblast cell. It was determined that 120 °C was the critical temperature for the hydrothermal treatment condition. Treatment below 120 °C could incorporate Ca into TiN surface, oxidize TiN surface partially and then improve the wettability while preserving its morphology and hardness. Fibroblast cell attachment and proliferation were improved and cell spreading was enhanced on hydrothermally treated specimens compared with untreated ones. Improved wettability, Ca incorporation and negative surface due to interstitial N were believed to be the main reasons. Hydrothermal treatment is expected to make TiN a promising dental implant coating with excellent abrasion resistance and good soft tissue affinity. - Highlights: • Ca was incorporated into TiN surface while not sacrificing its hardness. • Interstitial N due to oxidation promoted Ca adsorption and cell adhesion. • Hydrothermal treatment makes TiN a promising coating for dental implant.

  20. Niobium based coatings for dental implants

    International Nuclear Information System (INIS)

    Ramirez, G.; Rodil, S.E.; Arzate, H.; Muhl, S.; Olaya, J.J.

    2011-01-01

    Niobium based thin films were deposited on stainless steel (SS) substrates to evaluate them as possible biocompatible surfaces that might improve the biocompatibility and extend the life time of stainless steel dental implants. Niobium nitride and niobium oxide thin films were deposited by reactive unbalanced magnetron sputtering under standard deposition conditions without substrate bias or heating. The biocompatibility of the surfaces was evaluated by testing the cellular adhesion and viability/proliferation of human cementoblasts during different culture times, up to 7 days. The response of the films was compared to the bare substrate and pieces of Ti6Al4V; the most commonly used implant material for orthopedics and osteo-synthesis applications. The physicochemical properties of the films were evaluated by different means; X-ray diffraction, Rutherford backscattering spectroscopy and contact angle measurements. The results suggested that the niobium oxide films were amorphous and of stoichiometric Nb 2 O 5 (a-Nb 2 O 5 ), while the niobium nitride films were crystalline in the FCC phase (c-NbN) and were also stoichiometric with an Nb to N ratio of one. The biological evaluation showed that the biocompatibility of the SS could be improved by any of the two films, but neither was better than the Ti6Al4V alloy. On the other hand, comparing the two films, the c-NbN seemed to be a better surface than the oxide in terms of the adhesion and proliferation of human cemetoblasts.