WorldWideScience

Sample records for dental alloy sorting

  1. Biocompatibility of dental alloys

    Energy Technology Data Exchange (ETDEWEB)

    Braemer, W. [Heraeus Kulzer GmbH and Co. KG, Hanau (Germany)

    2001-10-01

    Modern dental alloys have been used for 50 years to produce prosthetic dental restorations. Generally, the crowns and frames of a prosthesis are prepared in dental alloys, and then veneered by feldspar ceramics or composites. In use, the alloys are exposed to the corrosive influence of saliva and bacteria. Metallic dental materials can be classified as precious and non-precious alloys. Precious alloys consist of gold, platinum, and small amounts of non-precious components such as copper, tin, or zinc. The non-precious alloys are based on either nickel or cobalt, alloyed with chrome, molybdenum, manganese, etc. Titanium is used as Grade 2 quality for dental purposes. As well as the dental casting alloys, high purity electroplated gold (99.8 wt.-%) is used in dental technology. This review discusses the corrosion behavior of metallic dental materials with saliva in ''in vitro'' tests and the influence of alloy components on bacteria (Lactobacillus casei and Streptococcus mutans). The test results show that alloys with high gold content, cobalt-based alloys, titanium, and electroplated gold are suitable for use as dental materials. (orig.)

  2. Grindability of dental magnetic alloys.

    Science.gov (United States)

    Hayashi, Eisei; Kikuchi, Masafumi; Okuno, Osamu; Kimura, Kohei

    2005-06-01

    In this study, the grindability of cast magnetic alloys (Fe-Pt-Nb magnetic alloy and magnetic stainless steel) was evaluated and compared with that of conventional dental casting alloys (Ag-Pd-Au alloy, Type 4 gold alloy, and cobalt-chromium alloy). Grindability was evaluated in terms of grinding rate (i.e., volume of metal removed per minute) and grinding ratio (i.e., volume ratio of metal removed compared to wheel material lost). Solution treated Fe-Pt-Nb magnetic alloy had a significantly higher grinding rate than the aged one at a grinding speed of 750-1500 m x min(-1). At 500 m x min(-1), there were no significant differences in grinding rate between solution treated and aged Fe-Pt-Nb magnetic alloys. At a lower speed of 500 m x min(-1) or 750 m x min(-1), it was found that the grinding rates of aged Fe-Pt-Nb magnetic alloy and stainless steel were higher than those of conventional casting alloys.

  3. In vivo effects of dental casting alloys

    Czech Academy of Sciences Publication Activity Database

    Venclíková, Z.; Benada, Oldřich; Bártová, J.; Joska, L.; Mrklas, L.; Procházková, J.; Stejskal, V.D.M.; Podzimek, Š.

    2006-01-01

    Roč. 27, č. 1 (2006), s. 25-32 ISSN 0172-780X R&D Projects: GA MZd NK7437 Institutional research plan: CEZ:AV0Z50200510 Keywords : dental alloys * metals * gingiva Subject RIV: EE - Microbiology, Virology Impact factor: 0.924, year: 2006

  4. Effects of chemical composition on the corrosion of dental alloys.

    Science.gov (United States)

    Galo, Rodrigo; Ribeiro, Ricardo Faria; Rodrigues, Renata Cristina Silveira; Rocha, Luís Augusto; de Mattos, Maria da Glória Chiarello

    2012-01-01

    The aim of this study was to determine the effect of the oral environment on the corrosion of dental alloys with different compositions, using electrochemical methods. The corrosion rates were obtained from the current-potential curves and electrochemical impedance spectroscopy (EIS). The effect of artificial saliva on the corrosion of dental alloys was dependent on alloy composition. Dissolution of the ions occurred in all tested dental alloys and the results were strongly dependent on the general alloy composition. Regarding the alloys containing nickel, the Ni-Cr and Ni-Cr-Ti alloys released 0.62 mg/L of Ni on average, while the Co-Cr dental alloy released ions between 0.01 and 0.03 mg/L of Co and Cr, respectively.The open-circuit potential stabilized at a higher level with lower deviation (standard deviation: Ni-Cr-6Ti = 32 mV/SCE and Co-Cr = 54 mV/SCE). The potenciodynamic curves of the dental alloys showed that the Ni-based dental alloy with >70 wt% of Ni had a similar curve and the Co-Cr dental alloy showed a low current density and hence a high resistance to corrosion compared with the Ni-based dental alloys. Some changes in microstructure were observed and this fact influenced the corrosion behavior for the alloys. The lower corrosion resistance also led to greater release of nickel ions to the medium. The quantity of Co ions released from the Co-Cr-Mo alloy was relatively small in the solutions. In addition, the quantity of Cr ions released into the artificial saliva from the Co-Cr alloy was lower than Cr release from the Ni-based dental alloys.

  5. 21 CFR 872.3070 - Dental amalgam, mercury, and amalgam alloy.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental amalgam, mercury, and amalgam alloy. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3070 Dental amalgam, mercury... elemental mercury, supplied as a liquid in bulk, sachet, or predosed capsule form, and amalgam alloy...

  6. Structure and grindability of dental Ti-Cr alloys

    International Nuclear Information System (INIS)

    Hsu, H.-C.; Wu, S.-C.; Chiang, T.-Y.; Ho, W.-F.

    2009-01-01

    The purpose of this study was to investigate the structure and microhardness of a series of binary Ti-Cr alloys with Cr contents up to 30 wt%. In addition, the grindability was also evaluated using an electric dental handpiece with SiC wheels, with the goal of developing a titanium alloy with better mechanical properties and machinability than commercially pure titanium (c.p. Ti), a metal generally considered to be difficult to machine. This study evaluated the phase and structure of Ti-Cr alloys, using an X-ray diffraction (XRD) for phase analysis and optical microscope for microstructure of the etched alloys. Grindability was evaluated by measuring the amount of metal volume removed after grinding for 1 min. Results indicated that the structure of Ti-Cr alloys is sensitive to the Cr content. The cast c.p. Ti has a hexagonal α phase. With 5 wt% Cr, metastable β phase starts to be retained. With Cr contents higher than 10 wt%, the equi-axed β phase is almost entirely retained. In addition, athermal ω phase was found in the Ti-5Cr and Ti-10Cr alloys. The largest quantity of ω phase and highest microhardness were found in Ti-10Cr alloy. The grinding rate of the Ti-Cr alloys showed a similar tendency to the microhardness. The Ti-10Cr alloy exhibited the best grindability, especially at 1000 m/min, which presumably due to the brittle nature of the alloy containing the ω phase in the β matrix.

  7. Influence of S. mutans on base-metal dental casting alloy toxicity.

    Science.gov (United States)

    McGinley, E L; Dowling, A H; Moran, G P; Fleming, G J P

    2013-01-01

    We have highlighted that exposure of base-metal dental casting alloys to the acidogenic bacterium Streptococcus mutans significantly increases cellular toxicity following exposure to immortalized human TR146 oral keratinocytes. With Inductively Coupled Plasma-Mass Spectrometry (ICP-MS), S. mutans-treated nickel-based (Ni-based) and cobalt-chromium-based (Co-Cr-based) dental casting alloys were shown to leach elevated levels of metal ions compared with untreated dental casting alloys. We targeted several biological parameters: cell morphology, viable cell counts, cell metabolic activity, cell toxicity, and inflammatory cytokine expression. S. mutans-treated dental casting alloys disrupted cell morphology, elicited significantly decreased viable cell counts (p casting alloys induced elevated levels of cellular toxicity compared with S. mutans-treated Co-Cr-based dental casting alloys. While our findings indicated that the exacerbated release of metal ions from S. mutans-treated base-metal dental casting alloys was the likely result of the pH reduction during S. mutans growth, the exact nature of mechanisms leading to accelerated dissolution of alloy-discs is not yet fully understood. Given the predominance of S. mutans oral carriage and the exacerbated cytotoxicity observed in TR146 cells following exposure to S. mutans-treated base-metal dental casting alloys, the implications for the long-term stability of base-metal dental restorations in the oral cavity are a cause for concern.

  8. Electronic structures of the L-cysteine film on dental alloys

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, K., E-mail: e7141@cc.saga-u.ac.jp [Synchrotron Light Application Center, Saga University, Saga 840-8502 (Japan); Tsujibayashi, T. [Department of Physics, Osaka Dental University, Osaka 573-1121 (Japan); Takahashi, K.; Azuma, J. [Synchrotron Light Application Center, Saga University, Saga 840-8502 (Japan); Kakimoto, K. [Department of Geriatric Dentistry, Osaka Dental University, Osaka 573-1121 (Japan); Kamada, M. [Synchrotron Light Application Center, Saga University, Saga 840-8502 (Japan)

    2011-04-15

    Research highlights: {yields} The electronic structures of dental alloys and L-cysteine film were studied by PES. {yields} The density of states in the dental alloy originates from Au and Cu as constituents. {yields} The Cu-3d states contribute dominantly to the occupied states near the Fermi level. {yields} The electronic structure of L-cysteine thin film is different from the thick film. {yields} The bonding between Cu-3d and S-3sp states are formed at the interface. - Abstract: Metal-organic interfaces have been attracting continuous attention in many fields including basic biosciences. The surface of dental alloys could be one of such interfaces since they are used in a circumstance full of organic compounds such as proteins and bacteria. In this work, electronic structures of Au-dominant dental alloys, which have Ag and Cu besides Au, and those of L-cysteine on the dental alloys have been studied by photoelectron spectroscopy with synchrotron radiation. It was found that the density of states in the dental alloy originate from gold and copper as constituents, and the Cu-3d states contribute dominantly to the occupied states near the Fermi level. It was also found that the electronic structure of the L-cysteine thin film on the dental alloy is different from that of the L-cysteine thick film. The result indicates the formation of the orbital bonding between Cu-3d and S-3sp states in the thin film on the dental alloy.

  9. Electronic structures of the L-cysteine film on dental alloys

    International Nuclear Information System (INIS)

    Ogawa, K.; Tsujibayashi, T.; Takahashi, K.; Azuma, J.; Kakimoto, K.; Kamada, M.

    2011-01-01

    Research highlights: → The electronic structures of dental alloys and L-cysteine film were studied by PES. → The density of states in the dental alloy originates from Au and Cu as constituents. → The Cu-3d states contribute dominantly to the occupied states near the Fermi level. → The electronic structure of L-cysteine thin film is different from the thick film. → The bonding between Cu-3d and S-3sp states are formed at the interface. - Abstract: Metal-organic interfaces have been attracting continuous attention in many fields including basic biosciences. The surface of dental alloys could be one of such interfaces since they are used in a circumstance full of organic compounds such as proteins and bacteria. In this work, electronic structures of Au-dominant dental alloys, which have Ag and Cu besides Au, and those of L-cysteine on the dental alloys have been studied by photoelectron spectroscopy with synchrotron radiation. It was found that the density of states in the dental alloy originate from gold and copper as constituents, and the Cu-3d states contribute dominantly to the occupied states near the Fermi level. It was also found that the electronic structure of the L-cysteine thin film on the dental alloy is different from that of the L-cysteine thick film. The result indicates the formation of the orbital bonding between Cu-3d and S-3sp states in the thin film on the dental alloy.

  10. Electronic structure of the L-cysteine films on dental alloys studied by ultraviolet photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Ogawa, K; Takahashi, K; Azuma, J; Kamada, M; Tsujibayashi, T; Ichimiya, M

    2013-01-01

    The valence electronic structures of the dental alloys, type 1, type 3, K14, and MC12 and their interaction with L-cysteine have been studied by ultraviolet photoelectron spectroscopy with synchrotron radiation. It was found that the electronic structures of the type-1 and type-3 dental alloys are similar to that of polycrystalline Au, while that of the K14 dental alloy is much affected by Cu. The electronic states of the MC12 dental alloy originate dominantly from Cu 3d states and Pd 4d states around the top of the valence bands, while the 4∼7-eV electronic structure of MC12 originates from the Ag 4d states. The peak shift and the change in shape due to alloying are observed in all the dental alloys. For the L-cysteine thin films, new peak or structure observed around 2 eV on all the dental alloys is suggested to be due to the bonding of S 3sp orbitals with the dental alloy surfaces. The Cu-S bond as well as the Au-S and Au-O bonds may cause the change in the electronic structure of the L-cysteine on type 1, type 3 and K14. For MC12, the interaction with L-cysteine may be dominantly due to the Pd-S, Cu-S, and Ag-O bonds, while the contribution of the Ag-S bond is small.

  11. Photoelectron spectroscopic study on the electronic structures of the dental gold alloys and their interaction with L-cysteine

    International Nuclear Information System (INIS)

    Ogawa, Koji; Takahashi, Kazutoshi; Azuma, Junpei; Kamada, Masao; Tsujibayashi, Toru; Ichimiya, Masayoshi; Fujimoto, Hitoshi; Sumimoto, Michinori

    2011-01-01

    The valence electronic structures of the dental gold alloys, type 1, type 3, and K14, and their interaction with L-cysteine have been studied by ultraviolet photoelectron spectroscopy with synchrotron radiation. It was found that the electronic structures of the type-1 and type-3 dental alloys are similar to that of polycrystalline Au, while that of the K14 dental alloy is much affected by Cu. The peak shift and the change in shape due to alloying are observed in all the dental alloys. It is suggested that the new peak observed around 2 eV for the L-cysteine thin films on all the dental alloys may be due to the bonding of S 3sp orbitals with the dental alloy surfaces, and the Cu-S bond, as well as the Au-S and Au-O bonds, may cause the change in the electronic structure of the L-cysteine on the alloys.

  12. Technical aspects of casting and their effect on the quality of Remanium CSe dental alloys

    Directory of Open Access Journals (Sweden)

    Dorota Klimecka-Tatar

    2016-03-01

    Full Text Available The study concerns on investigation of Remanium CSE alloy, one of the dental alloys used in metal-ceramic connection preparation. The alloys based on Ni-Cr-Mo are widely used in dental engineering because of their high mechanical, tribological properties as well as high corrosion resistance. The tested alloy has been processed in three ways – it has been remelted and then casted using three technologiescommonly used in dental laboratories, i.e. with: oxy-acetylene burner (1, induction furnace (2 and Volts arc (3. The aim of the study was to evaluate the effect of the melting and casting techniques on the mechanical strength and stereometric surface properties. The results revealed that the quality of Remanium CSe dental alloys significantly depend on the method of the material processing.

  13. Biocorrosion of dental alloys due to Desulfotomaculum nigrificans bacteria.

    Science.gov (United States)

    Mystkowska, Joanna

    2016-01-01

    Degradation processes of metallic biomaterials in the oral cavity limit the stability and reliability of dental materials. The influence of environment bacteria Desulfotomaculum nigrificans sulfate reducing bacteria on the corrosion processes of Co-Cr-Mo and Ti-6Al-4V alloys was assessed. After 28 and 56 days of contact of the materials with the bacterial environment, the surfaces of the biomaterials tested were observed by means of confocal scanning laser microscopy (CSLM), and their chemical composition was studied using X-Ray Photoelectron Spectrometry (XPS). Corrosive changes and the presence of sulfur (with medium atomic concentration of 0.5% for Co-Cr-Mo and 0.3% for Ti-6AL-4V) were observed on the surface of the biomaterials. Image analysis conducted using Aphelion software indicated that corrosion pits took up approx. 2.3% and 1.8% (after 28 days) and 4.2% and 3.1% (after 56 days) of the total test surfaces of cobalt and titanium alloys respectively. The greatest number of corrosion pits had a surface area within the range of 1-50 m2. They constituted from 37% up to 83% of all changes, depending on the type of material. An evident influence of the SRB on the surfaces of cobalt and titanium alloys was observed. Significant corrosive losses caused by the activity of microorganisms were observed on the metallic surfaces under study. The results of this study have much cognitive and utilitarian significance.

  14. Investigation of the mechanism of mercury removal from a silver dental amalgam alloy

    Directory of Open Access Journals (Sweden)

    M. DJURDJEVIC

    2004-12-01

    Full Text Available An investigation of silver dental amalgam decomposition and the mercury removal mechanism was performed. The decomposition process was analysed during thermal treatment in the temperature interval from 400 °C to 850 °C and for times from 0.5 to 7.5 h. The chemical compositions of the silver dental amalgam alloy and the treated alloy were tested and microstructure analysis using optical and scanning electron microscopy was carried out. The phases were identified using energy disperse electron probe microanalysis. A mechanism for the mercury removal process from silver dental amalgam alloy is suggested.

  15. The odontogenic potential of STRO-1 sorted rat dental pulp stem cells in vitro.

    NARCIS (Netherlands)

    Yang, X.; Dolder, J. van den; Walboomers, X.F.; Zhang, W.; Bian, Z.; Fan, M.; Jansen, J.A.

    2007-01-01

    The presence of heterogeneous cell populations in dental pulp may count for the considerable variation in the outcome of in vitro and in vivo experiments. Here, we intended to determine whether a minor cell sub-population of high proliferation and odontogenic potential existed among a larger

  16. Development of a discriminatory biocompatibility testing model for non-precious dental casting alloys.

    LENUS (Irish Health Repository)

    McGinley, Emma Louise

    2011-12-01

    To develop an enhanced, reproducible and discriminatory biocompatibility testing model for non-precious dental casting alloys, prepared to a clinically relevant surface finishing condition, using TR146 oral keratinocyte cells.

  17. Reciprocal interaction between dental alloy biocorrosion and Streptococcus mutans virulent gene expression.

    Science.gov (United States)

    Zhang, Songmei; Qiu, Jing; Ren, Yanfang; Yu, Weiqiang; Zhang, Fuqiang; Liu, Xiuxin

    2016-04-01

    Corrosion of dental alloys is a major concern in dental restorations. Streptococcus mutans reduces the pH in oral cavity and induces demineralization of the enamel as well as corrosion of restorative dental materials. The rough surfaces of dental alloys induced by corrosion enhance the subsequent accumulation of plaque. In this study, the corrosion process of nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) alloys in a nutrient-rich medium containing S. mutans was studied using inductively coupled plasma atomic emission spectrometry (ICP-AES), X-ray photoelectron spectroscopy (XPS) and electrochemical corrosion test. Our results showed that the release of Ni and Co ions increased, particularly after incubation for 3 days. The electrochemical corrosion results showed a significant decrease in the corrosion resistance (Rp) value after the alloys were immersed in the media containing S. mutans for 3 days. Correspondingly, XPS revealed a reduction in the relative dominance of Ni, Co, and Cr in the surface oxides after the alloys were immersed in the S. mutans culture. After removal of the biofilm, the pre-corroded alloys were re-incubated in S. mutans medium, and the expressions of genes associated with the adhesion and acidogenesis of S. mutans, including gtfBCD, gbpB, fif and ldh, were evaluated by detecting the mRNA levels using real-time reverse transcription polymerase chain reaction (RT-PCR). We found that the gtfBCD, gbpB, ftf and Idh expression of S. mutans were noticeably increased after incubation with pre-corroded alloys for 24 h. This study demonstrated that S. mutans enhanced the corrosion behavior of the dental alloys, on the other hand, the presence of corroded alloy surfaces up-regulated the virulent gene expression in S. mutans. Compared with smooth surfaces, the rough corroded surfaces of dental alloys accelerated the bacteria-adhesion and corrosion process by changing the virulence gene expression of S. mutans.

  18. Variations of color with alloying elements in Pd-free Au-Pt-based high noble dental alloys

    International Nuclear Information System (INIS)

    Shiraishi, Takanobu; Takuma, Yasuko; Miura, Eri; Fujita, Takeshi; Hisatsune, Kunihiro

    2007-01-01

    The effects of alloying addition of a small amount of base metals (In, Sn, Fe, Zn) on color variations in Pd-free Au-Pt-based high noble dental alloys were investigated in terms of rectilinear and polar color coordinates. The ternary Au-Pt-X (X = In, Sn, Fe, Zn) and quaternary Au-Pt-In-Y (Y = Sn, Fe, Zn) alloys were prepared from high purity component metals. The amount of alloying base metals, X and Y, were restricted up to 2 at.%. The alloying addition of a small amount of Fe, In, Sn, to a binary Au-10 at.% Pt alloy (referred to as AP10) effectively increased chroma, C *. On the other hand, the addition of Zn to the parent alloy AP10 did not change color coordinates greatly. The increase in chroma in the present Au-Pt-based high noble alloys was attributed to the increase in the slope of spectral reflectance curve at its absorption edge near 515 nm. It was found that the addition of a small amount of Fe to the parent alloy AP10 markedly increased lightness, L *, and the addition of Sn gave a very light tint of red to the parent alloy. Although red-green chromaticity index a * contributed to chroma to some extent, contribution of yellow-blue chromaticity index b * was much greater in determining chroma in this Pd-free Au-Pt-based multi-component alloys. The present results are expected to be valuable in case color is to be taken into account in designing Pd-free Au-Pt-based high noble dental alloys

  19. Variations of color with alloying elements in Pd-free Au-Pt-based high noble dental alloys

    Energy Technology Data Exchange (ETDEWEB)

    Shiraishi, Takanobu [Department of Dental and Biomedical Materials Science, Unit of Basic Medical Sciences, Graduate School of Biomedical Sciences, Nagasaki University, 1-7-1 Sakamoto, Nagasaki 852-8588 (Japan)]. E-mail: siraisi@nagasaki-u.ac.jp; Takuma, Yasuko [Department of Dental and Biomedical Materials Science, Unit of Basic Medical Sciences, Graduate School of Biomedical Sciences, Nagasaki University, 1-7-1 Sakamoto, Nagasaki 852-8588 (Japan); Miura, Eri [Department of Dental and Biomedical Materials Science, Unit of Basic Medical Sciences, Graduate School of Biomedical Sciences, Nagasaki University, 1-7-1 Sakamoto, Nagasaki 852-8588 (Japan); Fujita, Takeshi [Department of Dental and Biomedical Materials Science, Unit of Basic Medical Sciences, Graduate School of Biomedical Sciences, Nagasaki University, 1-7-1 Sakamoto, Nagasaki 852-8588 (Japan); Hisatsune, Kunihiro [Department of Dental and Biomedical Materials Science, Unit of Basic Medical Sciences, Graduate School of Biomedical Sciences, Nagasaki University, 1-7-1 Sakamoto, Nagasaki 852-8588 (Japan)

    2007-06-15

    The effects of alloying addition of a small amount of base metals (In, Sn, Fe, Zn) on color variations in Pd-free Au-Pt-based high noble dental alloys were investigated in terms of rectilinear and polar color coordinates. The ternary Au-Pt-X (X = In, Sn, Fe, Zn) and quaternary Au-Pt-In-Y (Y = Sn, Fe, Zn) alloys were prepared from high purity component metals. The amount of alloying base metals, X and Y, were restricted up to 2 at.%. The alloying addition of a small amount of Fe, In, Sn, to a binary Au-10 at.% Pt alloy (referred to as AP10) effectively increased chroma, C *. On the other hand, the addition of Zn to the parent alloy AP10 did not change color coordinates greatly. The increase in chroma in the present Au-Pt-based high noble alloys was attributed to the increase in the slope of spectral reflectance curve at its absorption edge near 515 nm. It was found that the addition of a small amount of Fe to the parent alloy AP10 markedly increased lightness, L *, and the addition of Sn gave a very light tint of red to the parent alloy. Although red-green chromaticity index a * contributed to chroma to some extent, contribution of yellow-blue chromaticity index b * was much greater in determining chroma in this Pd-free Au-Pt-based multi-component alloys. The present results are expected to be valuable in case color is to be taken into account in designing Pd-free Au-Pt-based high noble dental alloys.

  20. The release of elements from dental casting alloy into cell-culture medium and artificial saliva.

    Science.gov (United States)

    Can, Gülşen; Akpınar, Gül; Aydın, Ahmet

    2007-04-01

    The biocompatibility of dental casting alloys is a critical issue because these alloys are in long-term intimate contact with oral tissues. Since the biocompatibility of alloys is not completely known; the release of elements from the alloys has been studied. The aim of this study was to compare the elemental release from dental casting alloy during exposure to artificial saliva and cell-culture medium. Twenty specimens made from Ni-Cr alloy were provided in the form of 5 mm diameter discs, 2 mm in thickness with a 7 mm stem attached to one face to facilitate handling. Ten of twenty samples were polished separately using a conventional technique. The remaining ten samples were left sandblasted with 50 mum Al(2)0(3). Ten samples (5 polished, 5 sandblasted) were separately placed into cell-culture wells with Dulbecco's Modified Eagle's Medium. The other ten samples were placed separately into cell-culture wells with artificial saliva. The samples were subjected in contact with these medium for 30 days. These medium were collected every 7 days. The cell-culture medium and artificial saliva without alloy samples were subjected to elemental analyses as a control. At the end of the exposure time, Atomic Absorption Spectrometry (AAS) was used to determine the release of elements from the alloys into all collected medium. Statistical analyses were assessed with two-way ANOVA. In general, the elemental release occurred with in all medium. The elemental releases of sandblasted alloys were higher than polished alloys. Artificial saliva was found to cause more release from the samples. In both media, Ni released from polished and sandblasted alloys were higher than Cr and Mo. The results suggest that the release of elements from the alloys might have correlated with the environments and the surface of dental alloy.

  1. Mechanical properties and grindability of dental cast Ti-Nb alloys.

    Science.gov (United States)

    Kikuchi, Masafumi; Takahashi, Masatoshi; Okuno, Osamu

    2003-09-01

    Aiming at developing a dental titanium alloy with better mechanical properties and machinability than unalloyed titanium, a series of Ti-Nb alloys with Nb concentrations up to 30% was made. They were cast into magnesia-based molds using a dental casting machine and the mechanical properties and grindability of the castings were examined. The hardness of the alloys with Nb concentrations of 5% and above was significantly higher than that of titanium. The yield strength and tensile strength of the alloys with Nb concentrations of 10% and above were significantly higher than those of titanium, while the elongation was significantly lower. A small addition of niobium to titanium did not contribute to improving the grindability of titanium. The Ti-30% Nb alloy exhibited significantly better grindability at low grinding speed with higher hardness, strength, and Young's modulus than titanium, presumably due to precipitation of the omega phase in the beta matrix.

  2. Grindability of dental cast Ti-Ag and Ti-Cu alloys.

    Science.gov (United States)

    Kikuchi, Masafumi; Takahashi, Masatoshi; Okabe, Toru; Okuno, Osamu

    2003-06-01

    Experimental Ti-Ag alloys (5, 10, and 20 mass% Ag) and Ti-Cu alloys (2, 5, and 10 mass% Cu) were cast into magnesia molds using a dental casting machine, and their grindability was investigated. At the lowest grinding speed (500 m min(-1)), there were no statistical differences among the grindability values of the titanium and titanium alloys. The grindability of the alloys increased as the grinding speed increased. At the highest grinding speed (1500 m x min(-1)), the grindability of the 20% Ag, 5% Cu, and 10% Cu alloys was significantly higher than that of titanium. It was found that alloying with silver or copper improved the grindability of titanium, particularly at a high speed. It appeared that the decrease in elongation caused by the precipitation of small amounts of intermetallic compounds primarily contributed to the favorable grindability of the experimental alloys.

  3. Wear resistance of a pressable low-fusing ceramic opposed by dental alloys.

    Science.gov (United States)

    Faria, Adriana Cláudia Lapria; de Oliveira, André Almeida; Alves Gomes, Érica; Silveira Rodrigues, Renata Cristina; Faria Ribeiro, Ricardo

    2014-04-01

    Dental alloys have increasingly replaced by dental ceramics in dentistry because of aesthetics. As both dental alloys and ceramics can be present in the oral cavity, the evaluation of the wear resistance of ceramics opposed by dental alloys is important. The aim of the present study was to evaluate wear resistance of a pressable low-fusing ceramic opposed by dental alloys as well as the microhardness of the alloys and the possible correlation of wear and antagonist microhardness. Fifteen stylus tips samples of pressable low-fusing ceramic were obtained, polished and glazed. Samples were divided into three groups according to the disk of alloy/metal to be used as antagonist: Nickel-Chromium (Ni-Cr), Cobalt-Chromium (Co-Cr) and commercially pure titanium (cp Ti). Vickers microhardness of antagonist disks was evaluated before wear tests. Then, antagonist disks were sandblasted until surface roughness was adjusted to 0.75μm. Wear tests were performed at a speed of 60 cycles/min and distance of 10mm, in a total of 300,000 cycles. Before and after wear tests, samples were weighted and had their profile designed in an optical comparator to evaluate weight and height loss, respectively. Ni-Cr and cp Ti caused greater wear than Co-Cr, presenting greater weight (p=.009) and height (p=.002) loss. Cp Ti microhardness was lower than Ni-Cr and Co-Cr (pceramic presents different wear according to the dental alloy used as antagonist and the wear is not affected by antagonist microhardness. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Structure, mechanical properties and grindability of dental Ti-10Zr-X alloys

    International Nuclear Information System (INIS)

    Ho, W.-F.; Cheng, C.-H.; Pan, C.-H.; Wu, S.-C.; Hsu, H.-C.

    2009-01-01

    This study aimed to investigate the structure, mechanical properties and grindability of a binary Ti-Zr alloy added to a series of alloying elements (Nb, Mo, Cr and Fe). The phase and structure of Ti-10Zr-X alloys were evaluated using an X-ray diffraction (XRD) for phase analysis and optical microscope for microstructure of the etched alloys. Three-point bending tests were performed using a desk-top mechanical tester. Grindability was evaluated by measuring the amount of metal volume removed after grinding for 1 min at each of the four rotational speeds of the wheel (500, 750, 1000 or 1200 m/min). Results were compared with c.p. Ti, which was chosen as a control. Results indicated that the phase/crystal structure, microstructure, mechanical properties and grindability of the Ti-10Zr alloy can be significantly changed by adding small amounts of alloying elements. The alloying elements Nb, Mo, Cr and Fe contributed significantly to increasing the grinding ratio under all grinding conditions, although the grinding rate of all the metals was found to be largely dependent on grinding speed. The Ti-10Zr-1Mo alloy showed increases in microhardness (63%), bending strength (40%), bending modulus (30%) and elastic recovery angle (180%) over those of c.p. Ti, and was also found to have better grindability. The Ti-10Zr-1Mo alloy could therefore be used for prosthetic dental applications if other conditions necessary for dental casting are met

  5. Evaluation of the new TAMZ titanium alloy for dental cast application.

    Science.gov (United States)

    Zhang, Y M; Guo, T W; Li, Z C

    2000-12-01

    To reveal the potential of the new titanium alloy as dental prosthodontic materials. Dental castings of TAMZ alloy were investigated in the casting machine specially designed for titanium. A mesh pattern was used to count the castability value. The mechanical properties were measured by means of a universal testing machine. Optical micrography was done on the exposed cross-section of TAMZ alloy casting. From the surface to the inner part the Knoop hardness in reacted layer of TAMZ alloy casting was measured. The structure and elemental analyses of the reacted layer were made by SEM and element line scanning observation. The castability value (Cv = 98%) and the tensile test (sigma b = 850 Mpa, sigma 0.2 = 575 Mpa, delta = 7.33%) data were collected. The castings microstructure showed main alpha phase and small beta phase. Knoop hardness in the surface reacted layer was greater than that in the inner part. From the SEM and element line scanning observation, there are three different layers in the surface reacted layer of the TAMZ alloy castings, and higher level of element of O, Al, Si and Zr were found in the reacted layer while the Si permeated deeper than others. TAMZ alloy can be accepted as a material for dental alloy in prosthodontics.

  6. Dissolution ad uptake of cadmium from dental gold solder alloy implants

    International Nuclear Information System (INIS)

    Bergman, B.; Bergman, M.; Soeremark, R.

    1977-01-01

    Pure metallic cadmium was irradiated by means of thermal neutrons. The irradiated cadmium ( 115 Cd) was placed in bags of gold foil and the bags were implanted subcutaneously in the neck region of mice. Two and 3 d respectively after implantation the mice were killed, the bags removed and the animals subjected to whole-body autoradiography. The autoradiograms revealed an uptake of 115 Cd in liver and kidney. In another experiment specimens of a cadmium-containing dental gold solder alloy, a cadmium-free dental casting gold alloy and soldered assemblies made of these two alloys were implanted subcutaneously in the neck region of mice. The animals were killed after 6 months; cadmium analysis showed significant increases in the cadmium concentration in liver and kidney of those mice which had been given implants of gold solder alloy. The study clearly shows that due to electrochemical corrosion cadmium can be released from implants and accumulated in the kidneys and the liver. (author)

  7. The effect of urea on the corrosion behavior of different dental alloys.

    Science.gov (United States)

    Geckili, Onur; Bilhan, Hakan; Bilgin, Tayfun; Anthony von Fraunhofer, J

    2012-01-01

    Intraoral corrosion of dental alloys has biological, functional, and esthetic consequences. Since it is well known that the salivary urea concentrations undergo changes with various diseases, the present study was undertaken to determine the effect of salivary urea concentrations on the corrosion behavior of commonly used dental casting alloys. Three casting alloys were subjected to polarization scans in synthetic saliva with three different urea concentrations. Cyclic polarization clearly showed that urea levels above 20 mg/100 ml decreased corrosion current densities, increased the corrosion potentials and, at much higher urea levels, the breakdown potentials. The data indicate that elevated urea levels reduced the corrosion susceptibility of all alloys, possibly through adsorption of organics onto the metal surface. This study indicates that corrosion testing performed in sterile saline or synthetic saliva without organic components could be misleading.

  8. Properties of experimental copper-aluminium-nickel alloys for dental post-and-core applications.

    Science.gov (United States)

    Rittapai, Apiwat; Urapepon, Somchai; Kajornchaiyakul, Julathep; Harniratisai, Choltacha

    2014-06-01

    This study aimed to develop a copper-aluminium-nickel alloy which has properties comparable to that of dental alloys used for dental post and core applications with the reasonable cost. Sixteen groups of experimental copper alloys with variants of 3, 6, 9, 12 wt% Al and 0, 2, 4, 6 wt% Ni were prepared and casted. Their properties were tested and evaluated. The data of thermal, physical, and mechanical properties were analyzed using the two-way ANOVA and Tukey's test (α=0.05). The alloy toxicity was evaluated according to the ISO standard. The solidus and liquidus points of experimental alloys ranged from 1023℃ to 1113℃ and increased as the nickel content increased. The highest ultimate tensile strength (595.9 ± 14.2 MPa) was shown in the Cu-12Al-4Ni alloy. The tensile strength was increased as the both elements increased. Alloys with 3-6 wt% Al exhibited a small amount of 0.2% proof strength. Accordingly, the Cu-9Al-2Ni and Cu-9Al-4Ni alloys not only demonstrated an appropriate modulus of elasticity (113.9 ± 8.0 and 122.8 ± 11.3 GPa, respectively), but also had a value of 0.2% proof strength (190.8 ± 4.8 and 198.2 ± 3.4 MPa, respectively), which complied with the ISO standard requirement (>180 MPa). Alloys with the highest contents of nickel (6 wt% Ni) revealed a widespread decolourisation zone (5.0-5.9 mm), which correspondingly produced the largest cell response, equating positive control. The copper alloys fused with 9 wt% Al and 2-4 wt% Ni can be considered for a potential use as dental post and core applications.

  9. Influence of the casting processing route on the corrosion behavior of dental alloys.

    Science.gov (United States)

    Galo, Rodrigo; Rocha, Luis Augusto; Faria, Adriana Claudia; Silveira, Renata Rodrigues; Ribeiro, Ricardo Faria; de Mattos, Maria da Gloria Chiarello

    2014-12-01

    Casting in the presence of oxygen may result in an improvement of the corrosion performance of most alloys. However, the effect of corrosion on the casting without oxygen for dental materials remains unknown. The aim of this study was to investigate the influence of the casting technique and atmosphere (argon or oxygen) on the corrosion behavior response of six different dental casting alloys. The corrosion behavior was evaluated by electrochemical measurements performed in artificial saliva for the different alloys cast in two different conditions: arc melting in argon and oxygen-gas flame centrifugal casting. A slight decrease in open-circuit potential for most alloys was observed during immersion, meaning that the corrosion tendency of the materials increases due to the contact with the solution. Exceptions were the Co-based alloys prepared by plasma, and the Co-Cr-Mo and Ni-Cr-4Ti alloys processed by oxidized flame, in which an increase in potential was observed. The amount of metallic ions released into the artificial saliva solution during immersion was similar for all specimens. Considering the pitting potential, a parameter of high importance when considering the fluctuating conditions of the oral environment, Co-based alloys show the best performance in comparison with the Ni-based alloys, independent of the processing route. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. [Corrosion property and oxide film of dental casting alloys before and after porcelain firing].

    Science.gov (United States)

    Ma, Qian; Wu, Feng-ming

    2011-03-01

    To evaluate the types and compositions of oxide films formed during porcelain-fused-to-metal (PFM) firing on three kinds of dental casting alloys, and to investigate the corrosion property of these alloys in Dulbecco's modification of Eagle's medium (DMEM) cell culture fluid, before and after PFM firing. Specimens of three dental casting alloys (Ni-Cr, Co-Cr and Ni-Ti) before and after PFM firing were prepared, and were immersed in DMEM cell culture fluid. After 30 days, the type and concentration of released metal ions were measured using inductively coupled plasma atomic emission spectroscopy (ICP-AES). X-ray photoelectron spectroscopy (XPS) and scanning electron microscope (SEM) were used for analysis of oxide film on the alloys. One way-ANOVA was adopted in data analysis. The total amount of metal ions released from the three dental alloys was found to be highest in Ni-Cr alloy [(2.829 ± 0.694) mg/L], followed by Co-Cr [(2.120 ± 0.418) mg/L] and Ni-Ti alloy [(1.211 ± 0.101) mg/L]. The amount of Ni ions released from Ni-Cr alloys [(1.531 ± 0.392) mg/L] was higher than that from Ni-Ti alloys [(0.830 ± 0.052) mg/L]. The amount of Cr, Mo ions released from Co-Cr alloy [Cr: (0.048 ± 0.011) mg/L, Mo: (1.562 ± 0.333) mg/L] was higher than that from Ni-Cr alloy [Cr: (0.034 ± 0.002) mg/L, Mo: (1.264 ± 0.302) mg/L] and Ni-Ti alloy [Cr: (0.013 ± 0.006) mg/L, Mo: (0.151 ± 0.026) mg/L] (P < 0.05). After PFM firing, the total amount of metal irons released from the three dental alloys decreased [Ni-Cr: (0.861 ± 0.054) mg/L, Co-Cr: (0.695 ± 0.327) mg/L, Ni-Ti: (0.892 ± 0.115) mg/L] (P < 0.05). In addition, XPS showed increase of Cr(2)O(3) and Mo-Ni oxide on the surface of all the alloys after PFM firing. The amount of ions released from Ni-Cr alloy was the highest among the three dental casting alloys, this means Ni-Cr alloy is prone to corrode. The PFM firing process changed the alloys' surface composition. Increased Ni, Cr and Mo were found in oxide film, and

  11. Microstructural evidence of presence of beryllium in Ni-Cr alloys for dental prostheses

    International Nuclear Information System (INIS)

    Alkmin, L.B.; Nunes, C.A.; Santos, C.

    2010-01-01

    This study aimed to characterize the microstructure of commercial Ni-Cr alloys for dental prosthesis, with special focus on those containing Be. For this, the materials were characterized in terms of chemical composition, phases and melting point temperature. The following techniques were used: X-ray fluorescence, ICP-OES, scanning electron microscopy, electron probe microanalysis, X-ray diffraction and differential thermal analysis. The results clearly showed the presence of a typical eutectic, formed by the Ni ss and NiBe phases in those alloys containing Be, which can be considered a 'fingerprint' of the presence of this element in these alloys. (author)

  12. Effects of surface finishing conditions on the biocompatibility of a nickel-chromium dental casting alloy.

    LENUS (Irish Health Repository)

    McGinley, Emma Louise

    2011-07-01

    To assess the effects of surface finishing condition (polished or alumina particle air abraded) on the biocompatibility of direct and indirect exposure to a nickel-chromium (Ni-Cr) d.Sign®10 dental casting alloy on oral keratinocytes. Biocompatibility was performed by assessing cellular viability and morphology, metabolic activity, cellular toxicity and presence of inflammatory cytokine markers.

  13. Sensitization to palladium and nickel in Europe and the relationship with oral disease and dental alloys

    NARCIS (Netherlands)

    Muris, J.; Goossens, A.; Gonçalo, M.; Bircher, A.J.; Giménez-Arnau, A.; Foti, C.; Rustemeyer, T.; Feilzer, A.J.; Kleverlaan, C.J.

    2015-01-01

    Background The role of palladium and nickel sensitization in oral disease and dermatitis is not fully understood. Objectives To investigate whether sensitization to these metals was associated with exposure to dental alloys and oral and skin complaints/symptoms in a European multicentre study.

  14. Influence of shape and finishing on the corrosion of palladium-based dental alloys

    NARCIS (Netherlands)

    Milheiro, A.; Muris, J.; Kleverlaan, C.J.; Feilzer, A.J.

    2015-01-01

    PURPOSE: The purpose of this study was to evaluate the effects of the surface treatment and shape of the dental alloy on the composition of the prosthetic work and its metallic ion release in a corrosive medium after casting. MATERIALS AND METHODS: Orion Argos (Pd-Ag) and Orion Vesta (Pd-Cu) were

  15. Structural and morphological approach of Co-Cr dental alloys processed by alternative manufacturing technologies

    Science.gov (United States)

    Porojan, Sorin; Bîrdeanu, Mihaela; Savencu, Cristina; Porojan, Liliana

    2017-08-01

    The integration of digitalized processing technologies in traditional dental restorations manufacturing is an emerging application. The objective of this study was to identify the different structural and morphological characteristics of Co-Cr dental alloys processed by alternative manufacturing techniques in order to understand the influence of microstructure on restorations properties and their clinical behavior. Metallic specimens made of Co-Cr dental alloys were prepared using traditional casting (CST), and computerized milling (MIL), selective laser sintering (SLS) and selective laser melting (SLM). The structural information of the samples was obtained by X-ray diffraction, the morphology and the topography of the samples were investigated by Scanning Electron Microscopy and Atomic Force Microscope. Given that the microstructure was significantly different, further differences in the clinical behavior of prosthetic restorations manufactured using additive techniques are anticipated.

  16. The effect of hydrogen peroxide concentration on metal ion release from dental casting alloys.

    Science.gov (United States)

    Al-Salehi, S K; Hatton, P V; Johnson, A; Cox, A G; McLeod, C

    2008-04-01

    There are concerns that tooth bleaching agents may adversely affect dental materials. The aim of this study was to test the hypothesis that increasing concentrations of hydrogen peroxide (HP) are more effective than water at increasing metal ion release from two typical dental casting alloys during bleaching. Discs (n = 28 for each alloy) were prepared by casting and heat treated to simulate a typical porcelain-firing cycle. Discs (n = 7) of each alloy were immersed in either 0%, 3%, 10% or 30% (w/v) HP solutions for 24 h at 37 degrees C. Samples were taken for metal ion release determination using inductively coupled plasma-mass spectrometry and the data analysed using a two-way anova followed by a one-way anova. The surface roughness of each disc was measured using a Talysurf contact profilometer before and after bleaching and the data analysed using a paired t-test. With the exception of gold, the differences in metal ion concentration after treatment with 0% (control) and each of 3%, 10% and 30% HP (w/v) were statistically significant (P alloys increased with increasing HP concentrations (over 3000% increase in Ni and 1400% increase in Pd ions were recorded when HP concentration increased from 0% to 30%). Surface roughness values of the samples before and after bleaching were not significantly different (P > 0.05) Exposure of the two dental casting alloys to HP solutions increased metal ion release of all the elements except gold.

  17. Fabricating High-Quality 3D-Printed Alloys for Dental Applications

    Directory of Open Access Journals (Sweden)

    Min-Ho Hong

    2017-07-01

    Full Text Available Metal additive manufacturing (AM, especially selective laser melting (SLM, has been receiving particular attention because metallic functional structures with complicated configurations can be effectively fabricated using the technique. However, there still exist some future challenges for the fabrication of high-quality SLM products for dental applications. First, the surface quality of SLM products should be further improved by standardizing the laser process parameters or by appropriately post-treating the surface. Second, it should be guaranteed that dental SLM restorations have good dimensional accuracy and, in particular, a good marginal fit. Third, a definitive standard regarding building and scanning strategies, which affect the anisotropy, should be established to optimize the mechanical properties and fatigue resistance of SLM dental structures. Fourth, the SLM substructure’s bonding and support to veneering ceramic should be further studied to facilitate the use of esthetic dental restorations. Finally, the biocompatibility of SLM dental alloys should be carefully examined and improved to minimize the potential release of toxic metal ions from the alloys. Future research of SLM should focus on solving the above challenges, as well as on fabricating dental structures with “controlled” porosity.

  18. Structure, mechanical properties, and grindability of dental Ti-Zr alloys.

    Science.gov (United States)

    Ho, Wen-Fu; Chen, Wei-Kai; Wu, Shih-Ching; Hsu, Hsueh-Chuan

    2008-10-01

    Structure, mechanical properties and grindability of a series of binary Ti-Zr alloys with zirconium contents ranging from 10 to 40 wt% have been investigated. Commercially pure titanium (c.p. Ti) was used as a control. Experimental results indicated that the diffraction peaks of all the Ti-Zr alloys matched those for alpha Ti. No beta-phase peaks were found. The hardness of the Ti-Zr alloys increased as the Zr contents increased, and ranged from 266 HV (Ti-10Zr) to 350 HV (Ti-40Zr). As the concentration of zirconium in the alloys increased, the strength, elastic recovery angles and hardness increased. Moreover, the elastically recoverable angle of Ti-40Zr was higher than of c.p. Ti by as much as 550%. The grindability of each metal was found to be largely dependent on the grinding conditions. The Ti-40Zr alloy had a higher grinding rate and grinding ratio than c.p. Ti at low speed. The grinding rate of the Ti-40Zr alloy at 500 m/min was about 1.8 times larger than that of c.p. Ti, and the grinding ratio was about 1.6 times larger than that of c.p. Ti. Our research suggested that the Ti-40Zr alloy has better mechanical properties, excellent elastic recovery capability and improved grindability at low grinding speed. The Ti-40Zr alloy has a great potential for use as a dental machining alloy.

  19. Sorting Out Sorts

    OpenAIRE

    Jonathan B. Berk

    1998-01-01

    In this paper we analyze the theoretical implications of sorting data into groups and then running asset pricing tests within each group. We show that the way this procedure is implemented introduces a severe bias in favor of rejecting the model under consideration. By simply picking enough groups to sort into even the true asset pricing model can be shown to have no explanatory power within each group.

  20. Evaluation of cast Ti-Fe-O-N alloys for dental applications

    International Nuclear Information System (INIS)

    Koike, Marie; Ohkubo, Chikahiro; Sato, Hideki; Fujii, Hideki; Okabe, Toru

    2005-01-01

    Good mechanical properties, biocompatibility and corrosion resistance make titanium an excellent material for biomedical applications. However, when better mechanical properties than those offered by commercially pure titanium (CPTi) are needed, Ti-6Al-4V is sometimes a good alternative. Some new titanium alloys, developed as industrial structural materials, aim at an intermediate range of strength between that of CP Ti and Ti-6Al-4V. Two of these alloys are Super-TIX800TM (Ti-1% Fe-0.35% O-0.01% N) and Super-TIX800NTM (Ti-1% Fe-0.3% O-0.04% N) (both produced by Nippon Steel Corp., Japan). Besides being stronger than CP Ti, the cost of manufacturing these alloys is reportedly lower than for Ti-6Al-4V since they do not contain any expensive elements. In addition, they are not composed of elements such as aluminum or vanadium, which have caused biocompatibility concerns in medical and dental appliances. To evaluate these alloys as candidates for dental use, it is helpful to compare them to CP Ti (ASTM Grade 2) and Ti-6Al-4V (ASTM Grade 5), which have already been employed in dentistry. We evaluated the tensile properties, mold filling capacity, corrosion characteristics and grindability of these industrial alloys prepared by investment casting. Compared to the strengths of cast CPTi, the yield strength and tensile strength of these cast alloys were more than 20% and approximately 30% higher, respectively. On the other hand, both of these properties were 30% lower than for Ti-6Al-4V. Better grindability and wear resistance were additional benefits of these new alloys for dental applications

  1. Ni-Cr based dental alloys; Ni release, corrosion and biological evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Reclaru, L., E-mail: lucien.reclaru@pxgroup.com [PX Holding S.A., Dep R and D Corrosion and Biocompatibility Group, Bd. des Eplatures 42, CH-2304 La Chaux-de-Fonds (Switzerland); Unger, R.E.; Kirkpatrick, C.J. [Institute for Pathology, REPAIR Lab, University Medical Center, Johannes Gutenberg University Mainz, Langenbeckstr.1, D-55101 Mainz (Germany); Susz, C.; Eschler, P.-Y.; Zuercher, M.-H. [PX Holding S.A., Dep R and D Corrosion and Biocompatibility Group, Bd. des Eplatures 42, CH-2304 La Chaux-de-Fonds (Switzerland); Antoniac, I. [Materials Science and Engineering Faculty, Politehnica of Bucharest, 060042 Bucharest (Romania); Luethy, H. [Institute of Dental Materials Science and Technology, University of Basel, Hebelstrasse 3, CH-4056 Basel (Switzerland)

    2012-08-01

    In the last years the dental alloy market has undergone dramatic changes for reasons of economy and biocompatibility. Nickel based alloys have become widely used substitute for the much more expensive precious metal alloys. In Europe the prevalence of nickel allergy is 10-15% for female adults and 1-3% for male adults. Despite the restrictions imposed by the EU for the protection of the general population in contact dermatitis, the use of Ni-Cr dental alloys is on the increase. Some questions have to be faced regarding the safety risk of nickel contained in dental alloys. We have collected based on many EU markets, 8 Ni-Cr dental alloys. Microstructure characterization, corrosion resistance (generalized, crevice and pitting) in saliva and the quantities of cations released in particular nickel and CrVI have been evaluated. We have applied non parametric classification tests (Kendall rank correlation) for all chemical results. Also cytotoxicity tests and an evaluation specific to TNF-alpha have been conducted. According to the obtained results, it was found that their behavior to corrosion was weak but that nickel release was high. The quantities of nickel released are higher than the limits imposed in the EU concerning contact with the skin or piercing. Surprisingly the biological tests did not show any cytotoxic effect on Hela and L929 cells or any change in TNF-alpha expression in monocytic cells. The alloys did not show any proinflammatory response in endothelial cells as demonstrated by the absence of ICAM-1 induction. We note therefore that there is really no direct relationship between the in vitro biological evaluation tests and the physico-chemical characterization of these dental alloys. Clinical and epidemiological studies are required to clarify these aspects. - Highlights: Black-Right-Pointing-Pointer Nickel released was higher than the limits imposed in EU in contact with the skin. Black-Right-Pointing-Pointer No direct relationship between the

  2. An Investigation on Metallic Ion Release from Four Dental Casting Alloys

    Directory of Open Access Journals (Sweden)

    F. Nejatidanesh

    2005-12-01

    Full Text Available Statement of Problem: Element release from dental casting alloys into the oral environment is of clinical concern and is considered to be a potential health problem to all patients.Purpose: The aim of this study was to investigate the metallic ion release of four base metal alloys.Materials and Methods: Two Ni-Cr (Minalux and Supercast and two Co-Cr alloys (Minalia and Wironit were examined. Nine specimens of each type were prepared in 13×11×1.4 mm dimensions and each of the four alloys (3 specimens per group were conditioned in artificial saliva at 37 c for one, three and seven days.The conditioning media were analyzed for element-release using Inductive CoupledPlasma Atomic Emission Spectrophotometer (ICPAES. Collected data were statistically analyzed using ANOVA and Duncan multiple range test (P< 0.05.Results: The greatest amount of element release was seen after seven days (134.9 ppb Supercast, 159.2 ppb Minalux, 197.2 ppb Minalia, and 230.2 ppb Wironit. There was a significant difference between the released elements from the alloys after the three conditioning times (p<0.001.Conclusion: Element release from the studied alloys is proportional to the conditioning time. The Ni-Cr alloys tested in this investigation were more resistant to corrosion as compared to the Co-Cr alloys in artificial saliva. Supercast had the highest corrosion resistance.

  3. Cytotoxicity of dental alloys, metals, and ceramics assessed by millipore filter, agar overlay, and MTT tests.

    Science.gov (United States)

    Sjögren, G; Sletten, G; Dahl, J E

    2000-08-01

    Biocompatibility of dental materials is dependent on the release of elements from the materials. In addition, the composition, pretreatment, and handling of the materials influence the element release. This study evaluated the cytotoxicity of dental alloys, metals, and ceramics, with specific emphasis on the effects of altering the composition and the pretreatment. By using cells from a mouse fibroblast cell line and the agar overlay test, Millipore filter test, and MTT test, cytotoxicity of various metals, metal alloys, and ceramics for dental restoration were studied. Effects of altering the composition of a high noble gold alloy and of pretreatment of a ceramic-bonding alloy were also studied. In addition, the release of elements into the cell culture medium by the materials studied was measured using an inductively coupled plasma optical emission spectrophotometer. The results of the MTT test were analyzed statistically using ANOVA and Scheffé test at a significance level of P filter tests. For the MTT test, no significant differences were observed between these materials and controls, with the exception of JS C-gold and unalloyed titanium. The modified materials were ranked from "mildly cytotoxic" to "moderately cytotoxic" in the agar overlay and Millipore filter tests and from "noncytotoxic" to "moderately cytotoxic" in the MTT test. Thus, cytotoxicity was related to the alloy composition and treatment. The release of Cu and Zn seemed to be important for the cytotoxic effect. Alterations in the composition and the pretreatment can greatly influence the cytotoxicity, and the results stress the importance of carefully following the manufacturers' instructions when handling dental materials.

  4. Microstructure and mechanical properties of Ti-15Zr alloy used as dental implant material.

    Science.gov (United States)

    Medvedev, Alexander E; Molotnikov, Andrey; Lapovok, Rimma; Zeller, Rolf; Berner, Simon; Habersetzer, Philippe; Dalla Torre, Florian

    2016-09-01

    Ti-Zr alloys have recently started to receive a considerable amount of attention as promising materials for dental applications. This work compares mechanical properties of a new Ti-15Zr alloy to those of commercially pure titanium Grade4 in two surface conditions - machined and modified by sand-blasting and etching (SLA). As a result of significantly smaller grain size in the initial condition (1-2µm), the strength of Ti-15Zr alloy was found to be 10-15% higher than that of Grade4 titanium without reduction in the tensile elongation or compromising the fracture toughness. The fatigue endurance limit of the alloy was increased by around 30% (560MPa vs. 435MPa and 500MPa vs. 380MPa for machined and SLA-treated surfaces, respectively). Additional implant fatigue tests showed enhanced fatigue performance of Ti-15Zr over Ti-Grade4. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Surface and elemental alterations of dental alloys induced by electro discharge machining (EDM).

    Science.gov (United States)

    Zinelis, Spiros

    2007-05-01

    To evaluate the surface and elemental alterations induced by electro discharge machining (EDM) on the surface of dental cast alloys used for the fabrication of implant retained meso- and super-structures. A completed cast model of an arch that received dental implants was used for the preparation of six wax patterns which were divided into three groups (Au, Co and Ti). The wax patterns of the Au and Co groups were invested with conventional phosphate-bonded silica-based investment material and the Ti group with magnesia-based investment material. The investment rings of the Au and Co groups were cast with an Au-Ag alloy (Stabilor G) and a Co-Cr base alloy (Okta C), respectively, while the investment rings of group Ti were cast with cp Ti (Biotan). One casting of each group was subjected to electro discharge machining (EDM); the other was conventionally ground and polished. The surface morphology and the elemental compositions of conventionally and EDM-finished surfaces were studied by SEM/X-ray EDS analysis. Six spectra were collected from each surface employing the area scan mode and the mean value of each element between conventionally and EDM-finished surfaces was statistically analyzed by t-test (a=0.05). Then the specimens of each group were cut perpendicular to their longitudinal axis and after metallographic grinding and polishing the cross-sections studied under the SEM. The EDM surfaces showed a significant increase in C due to the decomposition of the dielectric fluid during spark erosion. Moreover, a significant Cu uptake was noted on these surfaces from the decomposition of the Cu electrodes used for EDM. Cross-sectional analysis showed that all alloys developed a superficial zone (recast layer) varying from 2 microm for Au-Ag to 10 microm for Co-Cr alloy. The elemental composition of dental alloy surfaces is significantly altered after EDM treatment.

  6. In vitro biocompatibility of CoCrMo dental alloys fabricated by selective laser melting.

    Science.gov (United States)

    Hedberg, Yolanda S; Qian, Bin; Shen, Zhijian; Virtanen, Sannakaisa; Wallinder, Inger Odnevall

    2014-05-01

    Selective laser melting (SLM) is increasingly used for the fabrication of customized dental components made of metal alloys such as CoCrMo. The main aim of the present study is to elucidate the influence of the non-equilibrium microstructure obtained by SLM on corrosion susceptibility and extent of metal release (measure of biocompatibility). A multi-analytical approach has been employed by combining microscopic and bulk compositional tools with electrochemical techniques and chemical analyses of metals in biologically relevant fluids for three differently SLM fabricated CoCrMo alloys and one cast CoCrMo alloy used for comparison. Rapid cooling and strong temperature gradients during laser melting resulted in the formation of a fine cellular structure with cell boundaries enriched in Mo (Co depleted), and suppression of carbide precipitation and formation of a martensitic ɛ (hcp) phase at the surface. These features were shown to decrease the corrosion and metal release susceptibility of the SLM alloys compared with the cast alloy. Unique textures formed in the pattern of the melting pools of the three different laser melted CoCrMo alloys predominantly explain observed small, though significant, differences. The susceptibility for corrosion and metal release increased with an increased number (area) of laser melt pool boundaries. This study shows that integrative and interdisciplinary studies of microstructural characteristics, corrosion, and metal release are essential to assess and consider during the design and fabrication of CoCrMo dental components of optimal biocompatibility. The reason is that the extent of metal release from CoCrMo is dependent on fabrication procedures. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  7. Corrosion behavior of dental alloys used for retention elements in prosthodontics.

    Science.gov (United States)

    Nierlich, Judith; Papageorgiou, Spyridon N; Bourauel, Christoph; Hültenschmidt, Robert; Bayer, Stefan; Stark, Helmut; Keilig, Ludger

    2016-06-01

    The purpose of this study was to investigate the corrosion behavior of 10 different high noble gold-based dental alloys, used for prosthodontic retention elements, according to ISO 10271. Samples of 10 high-noble and noble gold-based dental alloys were subjected to: (i) static immersion tests with subsequent analysis of ion release for eight different elements using mass spectrometry; (ii) electrochemical tests, including open-circuit potential and potentiodynamic scans; and (iii) scanning electron microscopy, followed by energy-dispersive X-ray microscopy. The results were analyzed using one-way ANOVA and Sidak multiple-comparisons post-hoc test at a level of significance of α = 0.05. Significant differences were found among the 10 alloys studied for all ions (P alloys. Scanning electron microscopy analysis confirmed the existence of typically small-diameter corrosion defects, whilst the energy-dispersive X-ray analysis found no significant alteration in the elemental composition of the alloys. The results of this study reveal the variability in the corrosive resistance among the materials used for retention elements in prosthodontics. © 2016 Eur J Oral Sci.

  8. [The effect of hydrogen peroxide on the electrochemical corrosion properties and metal ions release of nickel-chromium dental alloys].

    Science.gov (United States)

    Wang, Jue; Qiao, Guang-yan

    2013-04-01

    To investigate the effect of hydrogen peroxide on the electrochemical corrosion and metal ions release of nickel-chromium dental alloys. The corrosion resistance of nickel-chromium dental alloys was compared by electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization curve (PD) methods in artificial saliva after immersed in different concentrations of hydrogen peroxide for 112 h. The metal ions released from nickel-chromium dental alloys to the artificial saliva were detected after electrochemical measurements using inductively coupled plasma mass spectrometry (ICP-MS). The data was statistically analyzed by analysis of variance (ANOVA) using SPSS 13.0 software package. The electrochemical experiment showed that the sequence of polarization resistance in equivalent circuit (Rct), corrosion potential (Ecorr), pitting breakdown potential (Eb), and the difference between Ecorr and Eb representing the "pseudo-passivation" (δE) of nickel-chromium alloys in artificial saliva was 30% alloys to the artificial saliva, and the order of the concentrations of metal ions was 0% corrosion resistance of nickel-chromium dental alloys decrease after immersed in different concentrations of hydrogen peroxide for 112 h. Nickel-chromium dental alloys are more prone to corrosion in the artificial saliva with the concentration of hydrogen peroxide increased, and more metal ions are released in the artificial saliva.

  9. Mechanical Characterisation and Biomechanical and Biological Behaviours of Ti-Zr Binary-Alloy Dental Implants

    Directory of Open Access Journals (Sweden)

    Aritza Brizuela-Velasco

    2017-01-01

    Full Text Available The objective of the study is to characterise the mechanical properties of Ti-15Zr binary alloy dental implants and to describe their biomechanical behaviour as well as their osseointegration capacity compared with the conventional Ti-6Al-4V (TAV alloy implants. The mechanical properties of Ti-15Zr binary alloy were characterised using Roxolid© implants (Straumann, Basel, Switzerland via ultrasound. Their biomechanical behaviour was described via finite element analysis. Their osseointegration capacity was compared via an in vivo study performed on 12 adult rabbits. Young’s modulus of the Roxolid© implant was around 103 GPa, and the Poisson coefficient was around 0.33. There were no significant differences in terms of Von Mises stress values at the implant and bone level between both alloys. Regarding deformation, the highest value was observed for Ti-15Zr implant, and the lowest value was observed for the cortical bone surrounding TAV implant, with no deformation differences at the bone level between both alloys. Histological analysis of the implants inserted in rabbits demonstrated higher BIC percentage for Ti-15Zr implants at 3 and 6 weeks. Ti-15Zr alloy showed elastic properties and biomechanical behaviours similar to TAV alloy, although Ti-15Zr implant had a greater BIC percentage after 3 and 6 weeks of osseointegration.

  10. Evaluation of bonding strength of porcelain to some commercial nickel-base dental alloys and comparing their interface

    Directory of Open Access Journals (Sweden)

    Rahim Asghari Salavat

    2017-12-01

    Conclusion: To replace the replacing of deleterious elements from the chemical composition of dental alloys. The added new elements should control through the oxide layer and the formation of Cr2O3 in porcelain-alloy interfaces for adequate bond strength.

  11. Analysis of four dental alloys following torch/centrifugal and induction/ vacuum-pressure casting procedures.

    Science.gov (United States)

    Thompson, Geoffrey A; Luo, Qing; Hefti, Arthur

    2013-12-01

    Previous studies have shown casting methodology to influence the as-cast properties of dental casting alloys. It is important to consider clinically important mechanical properties so that the influence of casting can be clarified. The purpose of this study was to evaluate how torch/centrifugal and inductively cast and vacuum-pressure casting machines may affect the castability, microhardness, chemical composition, and microstructure of 2 high noble, 1 noble, and 1 base metal dental casting alloys. Two commonly used methods for casting were selected for comparison: torch/centrifugal casting and inductively heated/ vacuum-pressure casting. One hundred and twenty castability patterns were fabricated and divided into 8 groups. Four groups were torch/centrifugally cast in Olympia (O), Jelenko O (JO), Genesis II (G), and Liberty (L) alloys. Similarly, 4 groups were cast in O, JO, G, and L by an inductively induction/vacuum-pressure casting machine. Each specimen was evaluated for casting completeness to determine a castability value, while porosity was determined by standard x-ray techniques. Each group was metallographically prepared for further evaluation that included chemical composition, Vickers microhardness, and grain analysis of microstructure. Two-way ANOVA was used to determine significant differences among the main effects. Statistically significant effects were examined further with the Tukey HSD procedure for multiple comparisons. Data obtained from the castability experiments were non-normal and the variances were unequal. They were analyzed statistically with the Kruskal-Wallis rank sum test. Significant results were further investigated statistically with the Steel-Dwass method for multiple comparisons (α=.05). The alloy type had a significant effect on surface microhardness (Pcasting did not affect the microhardness of the test specimen (P=.465). Similarly, the interaction between the alloy and casting technique was not significant (P=.119). A high

  12. Comparative study of cytotoxicity of direct metal laser sintered and cast Co-Cr-Mo dental alloy

    Directory of Open Access Journals (Sweden)

    T. Puskar

    2015-07-01

    Full Text Available The presented work investigated the cytotoxicity of direct metal laser sintered (DMLS and cast Co-Cr-Mo (CCM dental alloy. In vitro tests were done on human fibroblast cell line MRC-5. There was no statistically significant difference in the cytotoxic effects of DMLS and CCM alloy specimens. The results of this investigation show good potential of DMLS Co-Cr-Mo alloy for application in dentistry.

  13. Macrophage proinflammatory response to the titanium alloy equipment in dental implantation.

    Science.gov (United States)

    Chen, X; Li, H S; Yin, Y; Feng, Y; Tan, X W

    2015-08-07

    Titanium alloy and stainless steel (SS) had been widely used as dental implant materials because of their affinity with epithelial tissue and connective tissue, and good physical, chemical, biological, mechanical properties and processability. We compared the effects of titanium alloy and SS on macrophage cytokine expression as well as their biocompatibility. Mouse macrophage RAW264.7 cells were cultured on titanium alloy and SS surfaces. Cells were counted by scanning electron microscopy. A nitride oxide kit was used to detect released nitric oxide by macrophages on the different materials. An enzyme linked immunosorbent assay was used to detect monocyte chemoattractant protein-1 levels. Scanning electron microscopy revealed fewer macrophages on the surface of titanium alloy (48.2 ± 6.4 x 10(3) cells/cm(2)) than on SS (135 ± 7.3 x 10(3) cells/cm(2)). The nitric oxide content stimulated by titanium alloy was 22.5 mM, which was lower than that stimulated by SS (26.8 mM), but the difference was not statistically significant (P = 0.07). The level of monocyte chemoattractant protein-1 released was significantly higher in the SS group (OD value = 0.128) than in the titanium alloy group (OD value = 0.081) (P = 0.024). The transforming growth factor-b1 mRNA expression levels in macrophages after stimulation by titanium alloy for 12 and 36 h were significantly higher than that after stimulation by SS (P = 0.31 and 0.25, respectively). Macrophages participate in the inflammatory response by regulating cytokines such as nitric oxide, monocyte chemoattractant protein-1, and transforming growth factor-b1. There were fewer macrophages and lower inflammation on the titanium alloy surface than on the SS surface. Titanium alloy materials exhibited better biological compatibility than did SS.

  14. Corrosion of dental alloys in artificial saliva with Streptococcus mutans.

    Science.gov (United States)

    Lu, Chunhui; Zheng, Yuanli; Zhong, Qun

    2017-01-01

    A comparative study of the corrosion resistance of CoCr and NiCr alloys in artificial saliva (AS) containing tryptic soy broth (Solution 1) and Streptococcus mutans (S. mutans) species (Solution 2) was performed by electrochemical methods, including open circuit potential measurements, impedance spectroscopy, and potentiodynamic polarization. The adherence of S. mutans to the NiCr and CoCr alloy surfaces immersed in Solution 2 for 24 h was verified by scanning electron microscopy, while the results of electrochemical impedance spectroscopy confirmed the importance of biofilm formation for the corrosion process. The R(QR) equivalent circuit was successfully used to fit the data obtained for the AS mixture without S. mutans, while the R(Q(R(QR))) circuit was found to be more suitable for describing the biofilm properties after treatment with the AS containing S. mutans species. In addition, a negative shift of the open circuit potential with immersion time was observed for all samples regardless of the solution type. Both alloys exhibited higher charge transfer resistance after treatment with Solution 2, and lower corrosion current densities were detected for all samples in the presence of S. mutans. The obtained results suggest that the biofilm formation observed after 24 h of exposure to S. mutans bacteria might enhance the corrosion resistance of the studied samples by creating physical barriers that prevented oxygen interactions with the metal surfaces.

  15. The effect of Electro Discharge Machining (EDM) on the corrosion resistance of dental alloys.

    Science.gov (United States)

    Ntasi, Argyro; Mueller, Wolf Dieter; Eliades, George; Zinelis, Spiros

    2010-12-01

    The aim of the present study was to evaluate the effect of Electro Discharge Machining (EDM) on the corrosion resistance of two types of dental alloys used for fabrication of implant retained superstructures. Two groups of specimens were prepared from a Co-Cr (Okta-C) and a grade II cpTi (Biotan) alloys respectively. Half of the specimens were subjected to EDM with Cu electrodes and the rest were conventionally finished (CF). The corrosion resistance of the alloys was evaluated by anodic polarization in Ringer's solution. Morphological and elemental alterations before and after corrosion testing were studied by SEM/EDX. Six regions were analyzed on each surface before and after corrosion testing and the results were statistically analyzed by paired t-test (a=0.05). EDM demonstrated inferior corrosion resistance compared to CF surfaces, the latter being passive in a wider range of potential demonstrating higher polarization resistance and lower I(corr) values. Morphological alterations were found before and after corrosion testing for both materials tested after SEM analysis. EDX showed a significant decrease in Mo, Cr, Co, Cu (Co-Cr) and Ti, Cu (cpTi) after electrochemical testing plus an increase in C. According to the results of this study the EDM procedure decreases the corrosion resistance of both the alloys tested, increasing thus the risk of possible adverse biological reactions. Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  16. Dissolution and uptake of cadmium from dental gold solder alloy implants

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, B; Bergman, M; Soeremark, R [Umeaa Univ. (Sweden); Karolinska Institutet, Stockholm (Sweden))

    1977-01-01

    Pure metallic cadmium was irradiated by means of thermal neutrons. The irradiated cadmium (/sup 115/Cd) was placed in bags of gold foil and the bags were implanted subcutaneously in the neck region of mice. Two and 3 d respectively after implantation the mice were killed, the bags removed and the animals subjected to whole-body autoradiography. The autoradiograms revealed an uptake of /sup 115/Cd in liver and kidney. In another experiment specimens of a cadmium-containing dental gold solder alloy, a cadmium-free dental casting gold alloy and soldered assemblies made of these two alloys were implanted subcutaneously in the neck region of mice. The animals were killed after 6 months; cadmium analysis showed significant increases in the cadmium concentration in liver and kidney of those mice which had been given implants of gold solder alloy. The study clearly shows that due to electrochemical corrosion cadmium can be released from implants and accumulated in the kidneys and the liver.

  17. Electrochemical and corrosion behavior of two chromium dental alloys in artificial bioenvironments

    Directory of Open Access Journals (Sweden)

    Banu Alexandra

    2017-01-01

    Full Text Available The purpose of this study is to compare the corrosion and tarnish behavior of NiCrMo and CoCrMo cast dental alloys in artificial bio environments. The cobalt chromium alloys are known and used in dentistry for many years, but its difficult machinability because of the strength and hardness, is an argument for scientists to study alternative materials with comparable biocompatibility. On the other hand, for dentistry devices beside corrosion behavior is important the aesthetic so, the used alloys have to preserve their shining and do not stain. The corrosion resistance has been evaluated using the Atomic mass spectroscopy method for ion release determination, the anodic polarization curves and the open circuit potential – time monitoring for corrosion behavior evaluation and optical microscopy for the structure analysis. The tarnish tendency of alloys was estimated using the method of cyclic immersion with frequency of 10 seconds for each minute during 72 hours in Na2S containing solution. The most important conclusion is that the alloys are comparable from corrosion and tarnish point of view, but we recommend to use the nickel base alloy only for orthodontic devices implanted for short periods of time, because of higher quantity of released ions.

  18. Evaluation of the mechanical properties and porcelain bond strength of cobalt-chromium dental alloy fabricated by selective laser melting.

    Science.gov (United States)

    Wu, Lin; Zhu, Haiting; Gai, Xiuying; Wang, Yanyan

    2014-01-01

    Limited information is available regarding the microstructure and mechanical properties of dental alloy fabricated by selective laser melting (SLM). The purpose of this study was to evaluate the mechanical properties of a cobalt-chromium (Co-Cr) dental alloy fabricated by SLM and to determine the correlation between its microstructure and mechanical properties and its porcelain bond strength. Five metal specimens and 10 metal ceramic specimens were fabricated to evaluate the mechanical properties of SLM Co-Cr dental alloy (SLM alloy) with a tensile test and its porcelain bond strength with a 3-point bending test. The relevant properties of the SLM alloy were compared with those of the currently used Co-Cr dental alloy fabricated with conventional cast technology (cast alloy). The Student t test was used to compare the results of the SLM alloy and the cast alloy (α=.05). The microstructure of the SLM alloy was analyzed with a metallographic microscope; the metal ceramic interface of the SLM porcelain bonded alloy was studied with scanning electron microscopy, energy dispersive x-ray spectroscopy, and an electron probe microanalyzer. Both the mean (standard deviation) yield strength (884.37 ± 8.96 MPa) and tensile strength (1307.50 ±10.65 MPa) of the SLM alloy were notably higher than yield strength (568.10 ± 30.94 MPa) and tensile strength (758.73 ± 25.85 MPa) of the currently used cast alloy, and the differences were significant (P.05). Microstructure analysis suggested that the SLM alloy had a dense and obviously orientated microstructure, which led to excellent mechanical properties. Analysis from scanning electron microscopy, energy dispersive x-ray spectroscopy, and the electron probe microanalyzer indicated that the SLM alloy had an intermediate layer with elemental interpenetration between the alloy and the porcelain, which resulted in an improved bonding interface. Compared with the currently used cast alloy, SLM alloy possessed improved mechanical

  19. Effect of preconditioning cobalt and nickel based dental alloys with Bacillus sp. extract on their surface physicochemical properties and theoretical prediction of Candida albicans adhesion

    Energy Technology Data Exchange (ETDEWEB)

    Balouiri, Mounyr, E-mail: b.mounyr@gmail.com [Faculté des Sciences et Techniques, Université Sidi Mohamed Ben Abdellah, BP 2202, 30007 Fez (Morocco); Bouhdid, Samira [Faculté des Sciences de Tétouan, Université Abdelmalek Essaadi, Avenue de Sebta, Mhannech II, 93002 Tétouan (Morocco); Sadiki, Moulay; Ouedrhiri, Wessal; Barkai, Hassan; El Farricha, Omar [Faculté des Sciences et Techniques, Université Sidi Mohamed Ben Abdellah, BP 2202, 30007 Fez (Morocco); Ibnsouda, Saad Koraichi [Faculté des Sciences et Techniques, Université Sidi Mohamed Ben Abdellah, BP 2202, 30007 Fez (Morocco); Cité de l' innovation, Université Sidi Mohamed Ben Abdellah, BP 2626, 30007 Fez (Morocco); Harki, El Houssaine [Faculté des Sciences et Techniques, Université Sidi Mohamed Ben Abdellah, BP 2202, 30007 Fez (Morocco)

    2017-02-01

    Biofilm formation on dental biomaterials is implicated in various oral health problems. Thus the challenge is to prevent the formation of this consortium of microorganisms using a safe approach such as antimicrobial and anti-adhesive natural products. Indeed, in the present study, the effects of an antifungal extract of Bacillus sp., isolated from plant rhizosphere, on the surface physicochemical properties of cobalt and nickel based dental alloys were studied using the contact angle measurements. Furthermore, in order to predict the adhesion of Candida albicans to the treated and untreated dental alloys, the total free energy of adhesion was calculated based on the extended Derjaguin-Landau-Verwey-Overbeek approach. Results showed hydrophobic and weak electron-donor and electron-acceptor characteristics of both untreated dental alloys. After treatment with the antifungal extract, the surface free energy of both dental alloys was influenced significantly, mostly for cobalt based alloy. In fact, treated cobalt based alloy became hydrophilic and predominantly electron donating. Those effects were time-dependent. Consequently, the total free energy of adhesion of C. albicans to this alloy became unfavorable after treatment with the investigated microbial extract. A linear relationship between the electron-donor property and the total free energy of adhesion has been found for both dental alloys. Also, a linear relationship has been found between this latter and the hydrophobicity for the cobalt based alloy. However, the exposure of nickel based alloy to the antifungal extract failed to produce the same effect. - Highlights: • Assessment of dental alloys physicochemical properties using contact angle method • Evaluation for the first time of microbial coating impact on dental alloys surface • Decrease of hydrophobicity of treated cobalt-chromium alloy with antifungal extract • Increase of Lewis base property of treated cobalt-chromium with treatment

  20. Effect of preconditioning cobalt and nickel based dental alloys with Bacillus sp. extract on their surface physicochemical properties and theoretical prediction of Candida albicans adhesion

    International Nuclear Information System (INIS)

    Balouiri, Mounyr; Bouhdid, Samira; Sadiki, Moulay; Ouedrhiri, Wessal; Barkai, Hassan; El Farricha, Omar; Ibnsouda, Saad Koraichi; Harki, El Houssaine

    2017-01-01

    Biofilm formation on dental biomaterials is implicated in various oral health problems. Thus the challenge is to prevent the formation of this consortium of microorganisms using a safe approach such as antimicrobial and anti-adhesive natural products. Indeed, in the present study, the effects of an antifungal extract of Bacillus sp., isolated from plant rhizosphere, on the surface physicochemical properties of cobalt and nickel based dental alloys were studied using the contact angle measurements. Furthermore, in order to predict the adhesion of Candida albicans to the treated and untreated dental alloys, the total free energy of adhesion was calculated based on the extended Derjaguin-Landau-Verwey-Overbeek approach. Results showed hydrophobic and weak electron-donor and electron-acceptor characteristics of both untreated dental alloys. After treatment with the antifungal extract, the surface free energy of both dental alloys was influenced significantly, mostly for cobalt based alloy. In fact, treated cobalt based alloy became hydrophilic and predominantly electron donating. Those effects were time-dependent. Consequently, the total free energy of adhesion of C. albicans to this alloy became unfavorable after treatment with the investigated microbial extract. A linear relationship between the electron-donor property and the total free energy of adhesion has been found for both dental alloys. Also, a linear relationship has been found between this latter and the hydrophobicity for the cobalt based alloy. However, the exposure of nickel based alloy to the antifungal extract failed to produce the same effect. - Highlights: • Assessment of dental alloys physicochemical properties using contact angle method • Evaluation for the first time of microbial coating impact on dental alloys surface • Decrease of hydrophobicity of treated cobalt-chromium alloy with antifungal extract • Increase of Lewis base property of treated cobalt-chromium with treatment

  1. Dental amalgam: effects of alloy/mercury mixing ratio, uses and waste management

    International Nuclear Information System (INIS)

    Kefi, I.; Maria, A.; Sana, J.; Afreen, J.; Adel, S.; Iftikhar, A.; Yawer, A.; Kaleem, M.

    2011-01-01

    Background: Silver dental amalgam is one of the oldest filling materials used in dentistry. The American Dental Association (ADA) has estimated that billions of amalgam restorations have been placed in patients in the last 150 years. Due to the presence of mercury and mishandling during the filling make it more controversial. The objective of this study was to conduct a survey of the use of different brands and to assess any deviations in practice from the hand mixing manual method of elemental mercury and alloy in a pestle/mortar and encapsulated form. Methods: A questionnaire was sent to 250 of randomly selected dental practitioner in various localities of Karachi. Data was analysed to record the specified brands used along with their powder/liquid (P/L) ratio and the different methods for disposing off mercury in this study. Results: The most commonly used form of dispensing method was hand mixing (57%) and only 30% of the dentists followed the manufacturer instruction for hand mixing ratio. Eighty-seven percent of dental amalgam restoration was performed and 13% removed by the dentist per month and the method of disposing the amalgam wastage that 55%, 25%, and 20% dentists were used the sink, bin and other methods respectively in their dental clinics. Conclusion: Amalgam restoration is still popular filling material in the posterior region of the mouth but we need to create awareness among the dentists who do not follow the ADA specifications. (author)

  2. Corrosive and cytotoxic properties of compact specimens and microparticles of Ni-Cr dental alloy.

    Science.gov (United States)

    Ristic, Ljubisa; Vucevic, Dragana; Radovic, Ljubica; Djordjevic, Snezana; Nikacevic, Milutin; Colic, Miodrag

    2014-04-01

    Nickel-chromium (Ni-Cr) dental alloys have been widely used in prosthodontic practice, but there is a permanent concern about their biocompatibility due to the release of metal ions. This is especially important when Ni-Cr metal microparticles are incorporated into gingival tissue during prosthodontic procedures. Therefore, the aim of this study was to examine and compare the corrosion and cytotoxic properties of compact specimens and microparticles of Ni-Cr dental alloy. Ni-Cr alloy, Remanium CSe bars (4 mm diameter), were made by the standard casting method and then cut into 0.5-mm-thick disks. Metal particles were obtained by scraping the bars using a diamond instrument for crown preparation. The microstructure was observed by an optical microscope. Quantitative determination and morphological and dimensional characterization of metal particles were carried out by a scanning electron microscope and Leica Application Suite software for image analysis. Corrosion was studied by conditioning the alloy specimens in the RPMI 1640 medium, containing 10% fetal calf serum in an incubator with 5% CO2 for 72 hours at 37°C. Inductively coupled plasma-optical emission spectrometry was used to assess metal ion release. The cytotoxity of conditioning medium (CM) was investigated on L929 cells using an MTT test. One-way ANOVA was used for statistical analysis. After casting, the microstructure of the Remanium CSe compact specimen composed of Ni, Cr, Mo, Si, Fe, Al, and Co had a typical dendritic structure. Alloy microparticles had an irregular shape with a wide size range: from less than 1 μm to more than 100 μm. The release of metal ions, especially Ni and Mo from microparticles, was significantly higher, compared to the compact alloy specimen. The CM prepared from compact alloy was not cytotoxic at any tested dilutions, whereas CM from alloy microparticles showed dose-dependent cytotoxicity (90% CM and 45% CM versus control; p alloy. This could affect health on long

  3. Comparative study on the corrosion behavior of Ti-Nb and TMA alloys for dental application in various artificial solutions

    International Nuclear Information System (INIS)

    Bai, Y.J.; Wang, Y.B.; Cheng, Y.; Deng, F.; Zheng, Y.F.; Wei, S.C.

    2011-01-01

    The corrosion behavior of Ti-Nb dental alloy in artificial saliva with and without the addition of lactic acid and sodium fluoride was investigated by electrochemical techniques, with the commercial Titanium-molybdenum alloy (TMA) as a comparison. The chemical composition, microstructure and constitutional phase were characterized via energy dispersive spectrometry, optical microscope and X-ray diffraction, meanwhile the open circuit potential, electrochemical impedance spectroscopy and potentiodynamic polarization measurements were carried out to study the corrosion resistance of experimental alloys, with the corroded surface being further characterized by scanning electron microscopy and X-ray photoelectron spectroscopy. It was found that the corrosion behavior of Ti-Nb alloy was similar to those TMA alloy samples in both artificial and acidified saliva solutions, whereas statistical analysis of the electrochemical impedance spectroscopy and polarization parameters showed Ti-Nb alloy exhibited better corrosion resistance in fluoridated saliva and fluoridated acidified saliva. SEM observation indicated that TMA alloy corroded heavily than Ti-Nb alloy in fluoride containing saliva. XPS surface analysis suggested that Nb 2 O 5 played an important role in anti-corrosion from the attack of fluoride ion. Based on the above finding, Ti-Nb alloy is believed to be suitable for the usage in certain fluoride treated dental works with excellent corrosion resistance in fluoride-containing oral media.

  4. Artifacts in MRI of the temporomandibular joint caused by dental alloys: a phantom study at 1.5 T

    International Nuclear Information System (INIS)

    Fellner, C.; Erlangen-Nuernberg Univ., Erlangen; Behr, M.; Fellner, F.; Held, P.; Handel, G.; Feuerbach, S.

    1997-01-01

    Purpose: The influence of dental alloys on MRI of the temporomandibular joint was studied using a phantom model for this joint. Methods: At 1,5 T, 15 dental alloys and 14 of their most important components were investigated acquiring sagittal (FOV: 150 mm) and transverse (FOV: 250 mm) T 1 -weighted SE additionally. The artifacts were assessed qualitatively as well as quantitatively, and the samples were subdivided into four artifact categories. Results: Ag, Cu, Ga, In, Ti, Sn, Zn, amalgan, the precious alloys, the Au-Pd and Ag-Pd alloys showed no artifacts (category I). Minimal artifacts below 10 mm on transverse images (category II) were found for Cr, Pd, Pt and for the Ni-Cr alloy. Mn and the remaining non-precious alloys induced artifacts up to 30 mm (category III). Significant artifacts - more than 30 mm - (category IV) were to be more susceptible for artifacts than T 1 -weighted SE and FLASH techniques. Conclusions: In contrast to dental alloys for fixed prosthodontics, Ni-Cr- or 18/8 wires used for orthodontic bands can influence not only the image quality, but also the diagnostic reliability of MRI of the temporomandibular joint. (orig.) [de

  5. Defects-tolerant Co-Cr-Mo dental alloys prepared by selective laser melting.

    Science.gov (United States)

    Qian, B; Saeidi, K; Kvetková, L; Lofaj, F; Xiao, C; Shen, Z

    2015-12-01

    CrCoMo alloy specimens were successfully fabricated using selective laser melting (SLM). The aim of this study was to carefully investigate microstructure of the SLM specimens in order to understand the influence of their structural features inter-grown on different length scales ranging from nano- to macro-levels on their mechanical properties. Two different sets of processing parameters developed for building the inner part (core) and the surface (skin) of dental prostheses were tested. Microstructures were characterized by SEM, EBSD and XRD analysis. The elemental distribution was assessed by EDS line profile analysis under TEM. The mechanical properties of the specimens were measured. The microstructures of both specimens were characterized showing formation of grains comprised of columnar sub-grains with Mo-enrichment at the sub-grain boundaries. Clusters of columnar sub-grains grew coherently along one common crystallographic direction forming much larger single crystal grains which are intercrossing in different directions forming an overall dendrite-like microstructure. Three types of microstructural defects were occasionally observed; small voids (10 μm). Despite the presence of these defects, the yield and the ultimate tensile strength (UTS) were 870 and 430MPa and 1300MPa and 1160MPa, respectively, for the skin and core specimens which are higher than casted dental alloy. Although the formation of microstructural defects is hard to be avoided during the SLM process, the SLM CoCrMo alloys can achieve improved mechanical properties than their casted counterparts, implying they are "defect-tolerant". Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  6. A new dental powder from nanocrystalline melt-spun Ag-Sn-Cu alloy ribbons

    International Nuclear Information System (INIS)

    Do-Minh, N.; Le-Thi, C.; Nguyen-Anh, S.

    2003-01-01

    A new non-gamma-two dental powder has been developed from nanocrystalline melt-spun Ag-Sn-Cu alloy ribbons. The amalgam made from this powder exhibits excellent properties for dental filling. The nanocrystalline microstructure was found for the first time in as-spun and heat treated Ag(27-28)Sn(9-32) Cu alloy ribbons, using X-ray diffraction, scanning electron microscopy and energy-dispersive spectroscopy. As-spun ribbons exhibited a multi-phase microstructure with preferred existence of β (Ag 4 Sn) phase formed during rapid solidification (RS) due to supersaturating of copper (Cu) atoms and homogenous nanostructure with subgrain size of about (40-50) nm, which seems to be developed during RS process and can be caused by eutectic reaction of the Ag 3 Sn/Ag 4 Sn-Cu 3 Sn system. In heat treated ribbons the clustering of Cu atoms was always favored and stable in an ageing temperature and time interval determined by Cu content. The heat treatment led to essential changes of subgrain morphology, resulted in the appearance of large-angle boundaries with fine Cu 3 Sn precipitates and forming typical recrystallization twins. Such a microstructure variation in melt-spun ribbons could eventually yield enhanced technological, clinical and physical properties of the dental products, controlled by the ADA Specification N deg 1 and reported before. Thus, using the rapid solidification technique a new non-gamma-two dental material of high quality, nanocrystalline ribbon powder, can be produced. Copyright (2003) AD-TECH - International Foundation for the Advancement of Technology Ltd

  7. Morphological Analysis (SEM) of the Surface of a Non-Noble Dental Alloy Subjected to Electrocorrosion

    Science.gov (United States)

    Baciu, E. R.; Grădinaru, I.; Baciu, M.; Vasluianu, R. I.; Cimpoesu, R.; Baciu, C.; Bejinariu, C.

    2017-06-01

    Corrosion consists in the degradation of a material under the chemical or electrochemical action of the environment where it is placed. The investigations carried out aimed to show the structural modifications produced in Co-Cr-Mo alloy, Robur 400 (Eisenbacher Dental - Waren ED GmbH, Germany) subjected to electrocorrosion in Fusayama-Mayer artificial saliva. The specimens prepared by mechanical polishing were analysed structurally by using a scanning electron microscope. During the tests run we could notice a general corrosion of the surfaces of the specimens made from Robur alloy. Through 2D and 3D microscopy and qualitative determinations of the luminous variation we could notice the effects of electrocorrosion tests on the surface of the metal material.

  8. Phase composition of rapidly solidified Ag-Sn-Cu dental alloys

    International Nuclear Information System (INIS)

    Lecong Dzuong; Do Minh Nghiep; Nguyen van Dzan; Cao the Ha

    1996-01-01

    The phase composition of some rapidly solidified Ag-Sn-Cu dental alloys with different copper contents (6.22 wtpct) has been studied by XRD, EMPA and optical microscopy. The samples were prepared from melt-spun ribbons. The microstructure of the as-quenched ribbons was microcrystalline and consisted of the Ag sub 3 Sn, Ag sub 4 Sn, Cu sub 3 Sn and Cu sub 3 Sn sub 8 phases. Mixing with mercury (amalgamation) led to formation of the Ag sub 2 Hg sub 3, Sn sub 7 Hg and Cu sub 6 Sn sub 5 phases. The amount of copper atoms in the alloys played an important role in phase formation in the amalgams

  9. Corrosion of Dental Au-Ag-Cu-Pd Alloys in 0.9 % Sodium Chloride Solution

    International Nuclear Information System (INIS)

    Chiba, Atsushi; Kusayanagi, Yukiharu

    2005-01-01

    Two Au-Ag-Cu-Pd dental casting alloys (Au:12% and 20%) used. The test solutions used 0.9 % NaCl solution (isotonic sodium chloride solution), 0.9 % NaCl solution containing 1 % lactic acid, and 0.9 % NaCl solution containing 1 % lactic acid and 0.1 mol dm -3 Na 2 S. The surface of two samples in three sample solutions was not natural discoloration during one year. The alloy containing 12 % gold was easily alloyed and the composition was uniform comparing with the alloy containing 20 % gold. The rest potentials have not a little effect after three months. The kinds of metals could not definitely from the oxidation and reduction waves of metal on the cyclic voltammograms. The dissolutions of gold and palladium were 12 % Au sample in the 0.9 % NaCl solution containing 1 % lactic acid and 0.1 mol dm -3 Na 2 S. The pH of solution had an affect on dissolution of copper, and sulfur ion had an affect on dissolution of silver. The copper dissolved amount from 20 % gold sample was about 26 times comparing with that of 12 % gold sample in the 0.9 % solution containing 1 % lactic acid. Corrosion products were silver chloride and copper chloride in NaCl solution, and silver sulfide and copper sulfide in NaCl solution containing Na 2 S

  10. Effects of Ni and Mo on the microstructure and some other properties of Co-Cr dental alloys

    International Nuclear Information System (INIS)

    Matkovic, Tanja; Matkovic, Prosper; Malina, Jadranka

    2004-01-01

    Influences of adding Ni and Mo on the microstructure and properties of as-cast Co-Cr base alloys have been investigated in order to determine the region of their optimal characteristics for biomedical application. The alloys were produced by arc-melting technique under argon atmosphere. Using optical metallography and scanning electron micro analyser it has been established that among 10 samples of Co-Cr-Ni alloys only samples 5 and 9 with the composition Co 55 Cr 40 Ni 5 and Co 60 Cr 30 Ni 10 have appropriate dendritic solidification microstructure. This microstructure, typical for commercial dental alloys, appears and beside greater number of as-cast Co-Cr-Mo alloys. The results of hardness and corrosion resistance measurements revealed the strong influence of different alloy chemistry and of as-cast microstructure. Hardness of alloys decreases with nickel content, but increases with chromium content. Therefore all Co-Cr-Ni alloys have significantly lower hardness than Co-Cr-Mo alloys. Corrosion resistance of alloys in artificial saliva was evaluated on the base of pitting potential. Superior corrosion characteristics have the samples with typical dendritic microstructure and higher chromium content, until nickel content have not significant effect. According to this, in ternary Co-Cr-Ni phase diagram was located the small concentration region (about samples 5 and 9) in them alloy properties can satisfied the high requirements for biomedical applications. This region is considerably larger in Co-Cr-Mo phase diagram

  11. Base-metal dental casting alloy biocompatibility assessment using a human-derived 3D oral mucosal model

    OpenAIRE

    MORAN, GARY; MC GINLEY, EMMA LOUISE; FLEMING, GARRY

    2012-01-01

    PUBLISHED Nickel-chromium (Ni-Cr) alloys used in fixed prosthodontics have been associated with type IV nickel-induced hypersensitivity. We hypothesized the full-thickness human-derived oral mucosa model employed for biocompatibility testing of base-metal dental alloys would provide insights into mechanisms of nickel-induced toxicity. Primary oral keratinocytes and gingival fibroblasts were seeded onto Alloderm? and maintained until full-thickness was achieved prior to Ni-Cr and cobalt-chr...

  12. Microstructure, mechanical properties, castability and in vitro biocompatibility of Ti-Bi alloys developed for dental applications.

    Science.gov (United States)

    Qiu, K J; Liu, Y; Zhou, F Y; Wang, B L; Li, L; Zheng, Y F; Liu, Y H

    2015-03-01

    In this study, the microstructure, mechanical properties, castability, electrochemical behaviors, cytotoxicity and hemocompatibility of Ti-Bi alloys with pure Ti as control were systematically investigated to assess their potential applications in the dental field. The experimental results showed that, except for the Ti-20Bi alloy, the microstructure of all other Ti-Bi alloys exhibit single α-Ti phase, while Ti-20Bi alloy is consisted of mainly α-Ti phase and a small amount of BiTi2 and BiTi3 phases. The tensile strength, hardness and wear resistance of Ti-Bi alloys were demonstrated to be improved monotonically with the increase of Bi content. The castability test showed that Ti-2Bi alloy increased the castability of pure Ti by 11.7%. The studied Ti-Bi alloys showed better corrosion resistance than pure Ti in both AS (artificial saliva) and ASFL (AS containing 0.2% NaF and 0.3% lactic acid) solutions. The concentrations of both Ti ion and Bi ion released from Ti-Bi alloys are extremely low in AS, ASF (AS containing 0.2% NaF) and ASL (AS containing 0.3% lactic acid) solutions. However, in ASFL solution, a large number of Ti and Bi ions are released. In addition, Ti-Bi alloys produced no significant deleterious effect to L929 cells and MG63 cells, similar to pure Ti, indicating a good in vitro biocompatibility. Besides, both L929 and MG63 cells perform excellent cell adhesion ability on Ti-Bi alloys. The hemolysis test exhibited that Ti-Bi alloys have an ultra-low hemolysis percentage below 1% and are considered nonhemolytic. To sum up, the Ti-2Bi alloy exhibits the optimal comprehensive performance and has great potential for dental applications. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  13. The influence of a hyperbaric environment and increased oxygen partial pressure on the corrosion of dental alloys.

    Science.gov (United States)

    Mehl, Christian; Heblich, Frank; Lenz, Rudolf; Ludwig, Klaus; Kern, Matthias

    2011-09-01

    The purpose of this in-vitro study was to determine whether there is a correlation between a hyperbaric environment or increased oxygen partial pressure and the corrosion of dental alloys used for dental restorations in divers. Samples of three commercially available dental alloys (palladium-based, reduced-gold-content and high-gold-content) were tested in the DIN EN ISO 1562 static immersion test and the amount of dissolved ions measured by atomic absorption spectrometry. The specimens were exposed to one of the following three conditions: normobaric and normoxic conditions (PO2 21 kPa); 608 kPa (6 bar, PO2 127 kPa) pressurised air in a pressure chamber or 506 kPa (5 bar, PO2 304 kPa) pressurised nitrox in a pressure chamber. None of the exposures suggested a correlation between increased ion solubility as a measure of corrosion and increased ambient pressure of the three alloys. The reduced-gold-content alloy released zinc ions at twice the weekly recommended dose. When the palladium-based alloy was exposed to a hyperbaric or hyperbaric/hyperoxic environment, ion solubility increased only slightly for gallium and silver. Within the limited sample size of the current study it can be concluded that hyperbaric and/or hyperoxic conditions do not seem to be a risk for increased corrosion for any of the three tested alloys.

  14. Comparison of Dental Prostheses Cast and Sintered by SLM from Co-Cr-Mo-W Alloy

    Directory of Open Access Journals (Sweden)

    Myszka D.

    2016-12-01

    Full Text Available The article presents the results of a comparative analysis of the metal substructure for dental prosthesis made from a Co-Cr-Mo-W alloy by two techniques, i.e. precision investment casting and selective laser melting (SLM. It was found that the roughness of the raw surface of the SLM sinter is higher than the roughness of the cast surface, which is compensated by the process of blast cleaning during metal preparation for the application of a layer of porcelain. Castings have a dendritic structure, while SLM sinters are characterized by a compact, fine-grain microstructure of the hardness higher by about 100 HV units. High performance and high costs of implementation the SLM technology are the cause to use it for the purpose of many dental manufacturers under outsourcing rules. The result is a reduction in manufacturing costs of the product associated with dental work time necessary to scan, designing and treatment of sinter compared with the time needed to develop a substructure in wax, absorption in the refractory mass, casting, sand blasting and finishing. As a result of market competition and low cost of materials, sinter costs decrease which brings the total costs related to the construction unit making using the traditional method of casting, at far less commitment of time and greater predictability and consistent sinter quality.

  15. Base-metal dental casting alloy biocompatibility assessment using a human-derived three-dimensional oral mucosal model.

    LENUS (Irish Health Repository)

    McGinley, E L

    2012-01-01

    Nickel-chromium (Ni-Cr) alloys used in fixed prosthodontics have been associated with type IV Ni-induced hypersensitivity. We hypothesised that the full-thickness human-derived oral mucosa model employed for biocompatibility testing of base-metal dental alloys would provide insights into the mechanisms of Ni-induced toxicity. Primary oral keratinocytes and gingival fibroblasts were seeded onto Alloderm™ and maintained until full thickness was achieved prior to Ni-Cr and cobalt-chromium (Co-Cr) alloy disc exposure (2-72 h). Biocompatibility assessment involved histological analyses with cell viability measurements, oxidative stress responses, inflammatory cytokine expression and cellular toxicity analyses. Inductively coupled plasma mass spectrometry analysis determined elemental ion release levels. We detected adverse morphology with significant reductions in cell viability, significant increases in oxidative stress, inflammatory cytokine expression and cellular toxicity for the Ni-Cr alloy-treated oral mucosal models compared with untreated oral mucosal models, and adverse effects were increased for the Ni-Cr alloy that leached the most Ni. Co-Cr demonstrated significantly enhanced biocompatibility compared with Ni-Cr alloy-treated oral mucosal models. The human-derived full-thickness oral mucosal model discriminated between dental alloys and provided insights into the mechanisms of Ni-induced toxicity, highlighting potential clinical relevance.

  16. [The effect of epigallocatechin gallate (EGCG) on the surface properties of nickel-chromium dental casting alloys after electrochemical corrosion].

    Science.gov (United States)

    Qiao, Guang-yan; Zhang, Li-xia; Wang, Jue; Shen, Qing-ping; Su, Jian-sheng

    2014-08-01

    To investigate the effect of epigallocatechin gallate (EGCG) on the surface properties of nickel-chromium dental alloys after electrochemical corrosion. The surface morphology and surface structure of nickel-chromium dental alloys were examined by stereomicroscope and scanning electron microscopy before and after electrochemical tests in 0 g/L and 1.0 g/L EGCG artificial saliva. The surface element component and chemical states of nickel-chromium dental alloys were analyzed by X-ray photoelectron spectrograph after electrochemical tests in 0 g/L and 1.0 g/L EGCG artificial saliva. More serious corrosion happened on the surface of nickel-chromium alloy in 1.0 g/L EGCG artificial saliva than in 0 g/L EGCG. The diameters of corrosion pits were smaller, and the dendrite structure of the alloy surface was not affected in 0 g/L EGCG. While the diameters of corrosion pits were larger, the dendritic interval of the alloy surface began to merge, and the dendrite structure was fuzzy in 1.0 g/L EGCG. In addition, the O, Ni, Cr, Be, C and Mo elements were detected on the surface of nickel-chromium alloys after sputtered for 120 s in 0 g/L EGCG and 1.0 g/L EGCG artificial saliva after electrochemical corrosion, and the surface oxides were mainly NiO and Cr(2)O(3). Compared with 0 g/L EGCG artificial saliva, the content of O, NiO and Cr(2)O(3) were lower in 1.0 g/L EGCG. The results of surface morphology and the corrosion products both show that the corrosion resistance of nickel-chromium alloys become worse and the oxide content of corrosion products on the surface reduce in 1.0 g/L EGCG artificial saliva.

  17. Are new TiNbZr alloys potential substitutes of the Ti6Al4V alloy for dental applications? An electrochemical corrosion study

    International Nuclear Information System (INIS)

    Ribeiro, Ana Lúcia Roselino; Hammer, Peter; Vaz, Luís Geraldo; Rocha, Luís Augusto

    2013-01-01

    The main aim of this work was to assess the electrochemical behavior of new Ti35Nb5Zr and Ti35Nb10Zr alloys in artificial saliva at 37 °C to verify if they are indicated to be used as biomaterials in dentistry as alternatives to Ti6Al4V alloys in terms of corrosion protection efficiency of the material. Electrochemical impedance spectroscopy (EIS) experiments were carried out for different periods of time (0.5–216 h) in a three-electrode cell, where the working electrode (Ti alloys) was exposed to artificial saliva at 37 °C. The near-surface region of the alloys was investigated using x-ray photoelectron spectroscopy (XPS). All alloys exhibited an increase in corrosion potential with the immersion time, indicating the growth and stabilization of the passive film. Ti35Nb5Zr and Ti6Al4V alloys had their EIS results interpreted by a double-layer circuit, while the Ti35Nb10Zr alloy was modeled by a one-layer circuit. In general, the new TiNbZr alloys showed similar behavior to that observed for the Ti6Al4V. XPS results suggest, in the case of the TiNbZr alloys, the presence of a thicker passive layer containing a lower fraction of TiO 2  phase than that of Ti6Al4V. After long-term immersion, all alloys develop a calcium phosphate phase on the surface. The new TiNbZr alloys appear as potential candidates to be used as a substitute to Ti6Al4V in the manufacturing of dental implant-abutment sets. (paper)

  18. Are new TiNbZr alloys potential substitutes of the Ti6Al4V alloy for dental applications? An electrochemical corrosion study.

    Science.gov (United States)

    Ribeiro, Ana Lúcia Roselino; Hammer, Peter; Vaz, Luís Geraldo; Rocha, Luís Augusto

    2013-12-01

    The main aim of this work was to assess the electrochemical behavior of new Ti35Nb5Zr and Ti35Nb10Zr alloys in artificial saliva at 37 °C to verify if they are indicated to be used as biomaterials in dentistry as alternatives to Ti6Al4V alloys in terms of corrosion protection efficiency of the material. Electrochemical impedance spectroscopy (EIS) experiments were carried out for different periods of time (0.5-216 h) in a three-electrode cell, where the working electrode (Ti alloys) was exposed to artificial saliva at 37 °C. The near-surface region of the alloys was investigated using x-ray photoelectron spectroscopy (XPS). All alloys exhibited an increase in corrosion potential with the immersion time, indicating the growth and stabilization of the passive film. Ti35Nb5Zr and Ti6Al4V alloys had their EIS results interpreted by a double-layer circuit, while the Ti35Nb10Zr alloy was modeled by a one-layer circuit. In general, the new TiNbZr alloys showed similar behavior to that observed for the Ti6Al4V. XPS results suggest, in the case of the TiNbZr alloys, the presence of a thicker passive layer containing a lower fraction of TiO2 phase than that of Ti6Al4V. After long-term immersion, all alloys develop a calcium phosphate phase on the surface. The new TiNbZr alloys appear as potential candidates to be used as a substitute to Ti6Al4V in the manufacturing of dental implant-abutment sets.

  19. The estimation of corrosion behaviour of ZrTi binary alloys for dental applications using electrochemical techniques

    International Nuclear Information System (INIS)

    Mareci, Daniel; Bolat, Georgiana; Chelariu, Romeu; Sutiman, Daniel; Munteanu, Corneliu

    2013-01-01

    Titanium and zirconium are in the same group in the periodic table of elements and are known to have similar physical and chemical properties. Both Ti and Zr usually have their surfaces covered by a thin oxide film spontaneously formed in air. However, the cytotoxicity of ZrO 2 is lower than that of TiO 2 rutile. Treatments with fluoride are known as the main methods to prevent plaque formation and dental caries. The corrosion behaviour of ZrTi alloys with Ti contents of 5, 25 and 45 wt.% and cp-Ti was investigated for dental applications. All samples were tested by linear potentiodynamic polarisation and electrochemical impedance spectroscopy (EIS) performed in artificial saliva with different pH levels (5.6 and 3.4) and different fluoride (1000 ppm F − ) and albumin protein (0.6%) contents. In addition, scanning electron microscopy (SEM) was employed to observe the surface morphology of the test materials after linear potentiodynamic polarisation. The corrosion current densities for the ZrTi alloys increased with the titanium content. The Zr5Ti and Zr25Ti alloys were susceptible to localised corrosion. The role that Ti plays as an alloying element is that of increasing the resistance of ZrTi alloy to localised corrosion. The presence of 0.6% albumin protein in fluoridated acidified artificial saliva with 1000 ppm F − could protect the cp-Ti and ZrTi alloys from attack by fluoride ions. - Highlights: • Electrochemical and corrosion behaviour of the new ZrTi alloys were investigated. • The passive behaviour for all the ZrTi alloys is observed. • Addition of Ti to Zr improves the corrosion resistance in some fluoridated saliva. • The presence of albumin could prevent the ZrTi alloys from attack by fluoride ions

  20. The estimation of corrosion behaviour of ZrTi binary alloys for dental applications using electrochemical techniques

    Energy Technology Data Exchange (ETDEWEB)

    Mareci, Daniel [“Gheorghe Asachi” Technical University of Iasi, Faculty of Chemical Engineering and Environmental Protection, Iasi (Romania); Bolat, Georgiana, E-mail: georgiana20022@yahoo.com [“Gheorghe Asachi” Technical University of Iasi, Faculty of Chemical Engineering and Environmental Protection, Iasi (Romania); Chelariu, Romeu [“Gheorghe Asachi” Technical University of Iasi, Faculty of Materials Science and Engineering, Iasi (Romania); Sutiman, Daniel [“Gheorghe Asachi” Technical University of Iasi, Faculty of Chemical Engineering and Environmental Protection, Iasi (Romania); Munteanu, Corneliu [“Gheorghe Asachi” Technical University of Iasi, Faculty of Mechanical, Iasi (Romania)

    2013-08-15

    Titanium and zirconium are in the same group in the periodic table of elements and are known to have similar physical and chemical properties. Both Ti and Zr usually have their surfaces covered by a thin oxide film spontaneously formed in air. However, the cytotoxicity of ZrO{sub 2} is lower than that of TiO{sub 2} rutile. Treatments with fluoride are known as the main methods to prevent plaque formation and dental caries. The corrosion behaviour of ZrTi alloys with Ti contents of 5, 25 and 45 wt.% and cp-Ti was investigated for dental applications. All samples were tested by linear potentiodynamic polarisation and electrochemical impedance spectroscopy (EIS) performed in artificial saliva with different pH levels (5.6 and 3.4) and different fluoride (1000 ppm F{sup −}) and albumin protein (0.6%) contents. In addition, scanning electron microscopy (SEM) was employed to observe the surface morphology of the test materials after linear potentiodynamic polarisation. The corrosion current densities for the ZrTi alloys increased with the titanium content. The Zr5Ti and Zr25Ti alloys were susceptible to localised corrosion. The role that Ti plays as an alloying element is that of increasing the resistance of ZrTi alloy to localised corrosion. The presence of 0.6% albumin protein in fluoridated acidified artificial saliva with 1000 ppm F{sup −} could protect the cp-Ti and ZrTi alloys from attack by fluoride ions. - Highlights: • Electrochemical and corrosion behaviour of the new ZrTi alloys were investigated. • The passive behaviour for all the ZrTi alloys is observed. • Addition of Ti to Zr improves the corrosion resistance in some fluoridated saliva. • The presence of albumin could prevent the ZrTi alloys from attack by fluoride ions.

  1. Precipitation hardening of a Cu-free Au-Ag-Pd-In dental alloy

    Energy Technology Data Exchange (ETDEWEB)

    Seol, Hyo-Joung [Department of Dental Materials, College of Dentistry and Research Institute for Oral Biotechnology, Pusan National University, 1-10 Ami-dong, Seo-gu, Pusan 602-739 (Korea, Republic of); Son, Kuk-Hyeon [Department of Dental Materials, College of Dentistry and Research Institute for Oral Biotechnology, Pusan National University, 1-10 Ami-dong, Seo-gu, Pusan 602-739 (Korea, Republic of); Yu, Chin-Ho [Department of Dental Materials, College of Dentistry and Research Institute for Oral Biotechnology, Pusan National University, 1-10 Ami-dong, Seo-gu, Pusan 602-739 (Korea, Republic of); Kwon, Yong Hoon [Department of Dental Materials, College of Dentistry and Research Institute for Oral Biotechnology, Pusan National University, 1-10 Ami-dong, Seo-gu, Pusan 602-739 (Korea, Republic of); Kim, Hyung-Il [Department of Dental Materials, College of Dentistry and Research Institute for Oral Biotechnology, Pusan National University, 1-10 Ami-dong, Seo-gu, Pusan 602-739 (Korea, Republic of)]. E-mail: hilkim@pusan.ac.kr

    2005-10-27

    The hardening mechanism and related microstructural changes of the Cu-free dental casting alloy composed of Au-Ag-Pd-In was examined by means of hardness test, X-ray diffraction (XRD), scanning electron microscopic (SEM) observations and electron probe microanalysis (EPMA). The Au-Ag-Pd-In alloy showed apparent age-hardenability. In the SEM photograph, three phases were observed in the solution-treated specimen, that is, the Au-Ag based phase with small amounts of In and Pd as matrix, the InPd phase as particle-like structures, and the Pd-rich phase as lamellar precipitates. By aging the specimen, the very fine Pd-rich inter-granular precipitates grew toward the grain interior as lamellar structure, and finally the coarsened Pd-rich precipitates covered a large part of the Au-Ag based matrix. The hardness increase in the early stage of the age-hardening process was assumed to be caused by the diffusion and aggregation of Pd atoms from the Au-Ag based matrix. The hardness decrease in the later stage of age-hardening process was caused by coarsening of the lamellar precipitates composed of the Pd-rich phase.

  2. Precipitation hardening of a Cu-free Au-Ag-Pd-In dental alloy

    International Nuclear Information System (INIS)

    Seol, Hyo-Joung; Son, Kuk-Hyeon; Yu, Chin-Ho; Kwon, Yong Hoon; Kim, Hyung-Il

    2005-01-01

    The hardening mechanism and related microstructural changes of the Cu-free dental casting alloy composed of Au-Ag-Pd-In was examined by means of hardness test, X-ray diffraction (XRD), scanning electron microscopic (SEM) observations and electron probe microanalysis (EPMA). The Au-Ag-Pd-In alloy showed apparent age-hardenability. In the SEM photograph, three phases were observed in the solution-treated specimen, that is, the Au-Ag based phase with small amounts of In and Pd as matrix, the InPd phase as particle-like structures, and the Pd-rich phase as lamellar precipitates. By aging the specimen, the very fine Pd-rich inter-granular precipitates grew toward the grain interior as lamellar structure, and finally the coarsened Pd-rich precipitates covered a large part of the Au-Ag based matrix. The hardness increase in the early stage of the age-hardening process was assumed to be caused by the diffusion and aggregation of Pd atoms from the Au-Ag based matrix. The hardness decrease in the later stage of age-hardening process was caused by coarsening of the lamellar precipitates composed of the Pd-rich phase

  3. Electrochemical assessment of some titanium and stainless steel implant dental alloys

    Directory of Open Access Journals (Sweden)

    Echevarría, A.

    2003-12-01

    Full Text Available Commercially pure titanium alloy, Ti-6Al-4V alloy and stainless steel screw implants were evaluated in both Ringer and synthetic saliva physiological solutions at body temperature by EIS (Electrochemical Impedance Spectroscopy with immersion times of 30 d. Results were simulated as a "sandwich system" composed by four capacitors-resistances connected in series with the solution resistance. A model explaining the results in terms of the porosity and thickness of four different layers, was proposed.

    Se utilizó la técnica de la Espectroscopia de Impedancia Electroquímica para evaluar en soluciones fisiológicas artificiales (Ringer y saliva sintética muestras extraídas de tornillos de implantes dentales certificados de titanio comercialmente puro, aleación Ti-6Al-W y acero inoxidable a temperatura corporal, con tiempos de inmersión hasta de 30 d. Los resultados se simularon mediante un modelo del tipo sandwich de cuatro elementos RC, conectados en serie con una resistencia de la solución. A partir de de esta simulación, se propone un modelo que explica los resultados obtenidos en términos de la evolución de la porosidad y el espesor de cuatro diferentes capas que se desarrollan en la superficie de los materiales evaluados.

  4. Ore sorting

    International Nuclear Information System (INIS)

    Hawkins, A.P.; Richards, A.W.

    1982-01-01

    In an ore sorting apparatus, ore particles are bombarded with neutrons in a chamber and sorted by detecting radiation emitted by isotopes of elements, such as gold, forming or contained in the particles, using detectors and selectively controlling fluid jets. The isotopes can be selectively recognised by their radiation characteristics. In an alternative embodiment, shorter life isotopes are formed by neutron bombardment and detection of radiation takes place immediately adjacent the region of bombardment

  5. Evaluation of mechanical properties of recasted dental base metal alloys for considering their reusability in dentistry and engineering field

    Directory of Open Access Journals (Sweden)

    Nandish Bantarahalli Thopegowda

    2014-01-01

    Full Text Available Background: Base metal casting alloys are extensively used in dentistry to fabricate many oral appliances and a huge amount is wasted in the form of sprues and buttons during the casting procedure. Recycling and reusing these alloys by clean technologies may save our natural resources from being depleted and as well reduce the cost of the treatment of the patients. Objectives: To study the mechanical properties of recasted dental base metal alloys, and explore possible ways to recycle and reuse in dentistry and other fields of science and technology. Materials and Methods: Two beryllium-free Cobalt-Chromium (Co-Cr dental casting alloys, Wironit and Wirobond-C, were used for this study. Six groups of specimen (melted once, twice, five, ten, fifteen and twenty times per each alloy were casted. The tensile strength and hardness of these samples were measured by using universal testing machine and Vickers hardness number (VHN tester. Results: Tensile strength decreased from 850 MPa to 777 MPa after 5 th recasting and to 674 MPa at the end of 20 th recasting procedure for the Wironit samples. For Wirobond-C samples, tensile strength decreased from 720 MPa to 678 MPa after 5 th recasting and further reduced to 534 MPa at the end of 20 th recasting procedure. Hardness decreased from 380VHN to 335VHN at the end of 20 th recasting for Wironit samples and 328VHN to 247VHN for Wirobond-C samples after 20 th recasting procedure. The slight decrease in their mechanical properties will not have any impact on the clinical performance for dental applications. Conclusion: There is no major degradation in the mechanical properties after recycling, and hence, the left over alloys after casting procedures can be reused in dentistry with a condition to satisfy cytotoxicity tests.

  6. Artefacts in multimodal imaging of titanium, zirconium and binary titanium-zirconium alloy dental implants: an in vitro study.

    Science.gov (United States)

    Smeets, Ralf; Schöllchen, Maximilian; Gauer, Tobias; Aarabi, Ghazal; Assaf, Alexandre T; Rendenbach, Carsten; Beck-Broichsitter, Benedicta; Semmusch, Jan; Sedlacik, Jan; Heiland, Max; Fiehler, Jens; Siemonsen, Susanne

    2017-02-01

    To analyze and evaluate imaging artefacts induced by zirconium, titanium and titanium-zirconium alloy dental implants. Zirconium, titanium and titanium-zirconium alloy implants were embedded in gelatin and MRI, CT and CBCT were performed. Standard protocols were used for each modality. For MRI, line-distance profiles were plotted to quantify the accuracy of size determination. For CT and CBCT, six shells surrounding the implant were defined every 0.5 cm from the implant surface and histogram parameters were determined for each shell. While titanium and titanium-zirconium alloy induced extensive signal voids in MRI owing to strong susceptibility, zirconium implants were clearly definable with only minor distortion artefacts. For titanium and titanium-zirconium alloy, the MR signal was attenuated up to 14.1 mm from the implant. In CT, titanium and titanium-zirconium alloy resulted in less streak artefacts in comparison with zirconium. In CBCT, titanium-zirconium alloy induced more severe artefacts than zirconium and titanium. MRI allows for an excellent image contrast and limited artefacts in patients with zirconium implants. CT and CBCT examinations are less affected by artefacts from titanium and titanium-zirconium alloy implants compared with MRI. The knowledge about differences of artefacts through different implant materials and image modalities might help support clinical decisions for the choice of implant material or imaging device in the clinical setting.

  7. Artefacts in multimodal imaging of titanium, zirconium and binary titanium–zirconium alloy dental implants: an in vitro study

    Science.gov (United States)

    Schöllchen, Maximilian; Aarabi, Ghazal; Assaf, Alexandre T; Rendenbach, Carsten; Beck-Broichsitter, Benedicta; Semmusch, Jan; Sedlacik, Jan; Heiland, Max; Fiehler, Jens; Siemonsen, Susanne

    2017-01-01

    Objectives: To analyze and evaluate imaging artefacts induced by zirconium, titanium and titanium–zirconium alloy dental implants. Methods: Zirconium, titanium and titanium–zirconium alloy implants were embedded in gelatin and MRI, CT and CBCT were performed. Standard protocols were used for each modality. For MRI, line–distance profiles were plotted to quantify the accuracy of size determination. For CT and CBCT, six shells surrounding the implant were defined every 0.5 cm from the implant surface and histogram parameters were determined for each shell. Results: While titanium and titanium–zirconium alloy induced extensive signal voids in MRI owing to strong susceptibility, zirconium implants were clearly definable with only minor distortion artefacts. For titanium and titanium–zirconium alloy, the MR signal was attenuated up to 14.1 mm from the implant. In CT, titanium and titanium–zirconium alloy resulted in less streak artefacts in comparison with zirconium. In CBCT, titanium–zirconium alloy induced more severe artefacts than zirconium and titanium. Conclusions: MRI allows for an excellent image contrast and limited artefacts in patients with zirconium implants. CT and CBCT examinations are less affected by artefacts from titanium and titanium–zirconium alloy implants compared with MRI. The knowledge about differences of artefacts through different implant materials and image modalities might help support clinical decisions for the choice of implant material or imaging device in the clinical setting. PMID:27910719

  8. Measurement of in-vivo dosage increase due to dental alloys during therapeutic irradiation of the mouth cavity

    International Nuclear Information System (INIS)

    Thilmann, C.; Mose, S.; Saran, F.; Schopohl, B.; Boettcher, H.D.

    1995-01-01

    The degree of dosage increase in the immediate surrounding of metallic dental materials was measured in an in-vivo study during therapeutic irradiation with 60 Co gamma rays in the area of mouth cavity of 11 patients. Measurements were carried out by thermoluminescent dosimetry at permamently fixed golden teeth and alloy specimens containing gold and palladium and amalgam. The following relative dodage values according to a simultanelusly measured reference value were measured at the surface of the different dental materials: 161% near fixed golden caps, 168% near the specimen containing gold in a high percentage, 133% near the specimen of palladium and 161% near the specimen of amalgam. The in vivo measured dosage increases due to metallic dental prosthesis are less than values obtained using back scatter arramgements for irradiating phantoms. Despite this, they could be of clinical relevance. Thus the usage of a mucous membrane protection during irradiation with 60 Co, as a means of preventing local lesions of the oral mucosa, due to dental alloys within the treatment volume remains inevitable. (orig.) [de

  9. Chemical passivation as a method of improving the electrochemical corrosion resistance of Co-Cr-based dental alloy.

    Science.gov (United States)

    Rylska, Dorota; Sokołowski, Grzegorz; Sokołowski, Jerzy; Łukomska-Szymańska, Monika

    2017-01-01

    The purpose of the study was to evaluate corrosion resistance of Wirobond C® alloy after chemical passivation treatment. The alloy surface undergone chemical passivation treatment in four different media. Corrosion studies were carried out by means of electrochemical methods in saline solution. Corrosion effects were determined using SEM. The greatest increase in the alloy polarization resistance was observed for passive layer produced in Na2SO4 solution with graphite. The same layer caused the highest increase in corrosion current. Generally speaking, the alloy passivation in Na2SO4 solution with graphite caused a substantial improvement of the corrosion resistance. The sample after passivation in Na2SO4 solution without graphite, contrary to others, lost its protective properties along with successive anodic polarization cycles. The alloy passivation in Na3PO4 solution with graphite was the only one that caused a decrease in the alloy corrosion properties. The SEM studies of all samples after chemical passivation revealed no pit corrosion - in contrast to the sample without any modification. Every successive polarization cycle in anodic direction of pure Wirobond C® alloy enhances corrosion resistance shifting corrosion potential in the positive direction and decreasing corrosion current value. The chemical passivation in solutions with low pH values decreases susceptibility to electrochemical corrosion of Co-Cr dental alloy. The best protection against corrosion was obtained after chemical passivation of Wirobond C® in Na2SO4 solution with graphite. Passivation with Na2SO4 in solution of high pH does not cause an increase in corrosion resistance of WIROBOND C. Passivation process increases alloy resistance to pit corrosion.

  10. Microstructures and mechanical properties of Co-29Cr-6Mo alloy fabricated by selective laser melting process for dental applications.

    Science.gov (United States)

    Takaichi, Atsushi; Suyalatu; Nakamoto, Takayuki; Joko, Natsuka; Nomura, Naoyuki; Tsutsumi, Yusuke; Migita, Satoshi; Doi, Hisashi; Kurosu, Shingo; Chiba, Akihiko; Wakabayashi, Noriyuki; Igarashi, Yoshimasa; Hanawa, Takao

    2013-05-01

    The selective laser melting (SLM) process was applied to a Co-29Cr-6Mo alloy, and its microstructure, mechanical properties, and metal elution were investigated to determine whether the fabrication process is suitable for dental applications. The microstructure was evaluated using scanning electron microscopy with energy-dispersed X-ray spectroscopy (SEM-EDS), X-ray diffractometry (XRD), and electron back-scattered diffraction pattern analysis. The mechanical properties were evaluated using a tensile test. Dense builds were obtained when the input energy of the laser scan was higher than 400 J mm⁻³, whereas porous builds were formed when the input energy was lower than 150 J mm⁻³. The microstructure obtained was unique with fine cellular dendrites in the elongated grains parallel to the building direction. The γ phase was dominant in the build and its preferential orientation was confirmed along the building direction, which was clearly observed for the builds fabricated at lower input energy. Although the mechanical anisotropy was confirmed in the SLM builds due to the unique microstructure, the yield strength, UTS, and elongation were higher than those of the as-cast alloy and satisfied the type 5 criteria in ISO22764. Metal elution from the SLM build was smaller than that of the as-cast alloy, and thus, the SLM process for the Co-29Cr-6Mo alloy is a promising candidate for fabricating dental devices. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Annealing of Co-Cr dental alloy: effects on nanostructure and Rockwell hardness.

    Science.gov (United States)

    Ayyıldız, Simel; Soylu, Elif Hilal; Ide, Semra; Kılıç, Selim; Sipahi, Cumhur; Pişkin, Bulent; Gökçe, Hasan Suat

    2013-11-01

    The aim of the study was to evaluate the effect of annealing on the nanostructure and hardness of Co-Cr metal ceramic samples that were fabricated with a direct metal laser sintering (DMLS) technique. Five groups of Co-Cr dental alloy samples were manufactured in a rectangular form measuring 4 × 2 × 2 mm. Samples fabricated by a conventional casting technique (Group I) and prefabricated milling blanks (Group II) were examined as conventional technique groups. The DMLS samples were randomly divided into three groups as not annealed (Group III), annealed in argon atmosphere (Group IV), or annealed in oxygen atmosphere (Group V). The nanostructure was examined with the small-angle X-ray scattering method. The Rockwell hardness test was used to measure the hardness changes in each group, and the means and standard deviations were statistically analyzed by one-way ANOVA for comparison of continuous variables and Tukey's HSD test was used for post hoc analysis. P values of directly affected both the nanostructure and hardness of the Co-Cr alloy. Group III exhibited a non-homogeneous structure and increased hardness (48.16 ± 3.02 HRC) because the annealing process was incomplete and the inner stress was not relieved. Annealing in argon atmosphere of Group IV not only relieved the inner stresses but also decreased the hardness (27.40 ± 3.98 HRC). The results of fitting function presented that Group IV was the most homogeneous product as the minimum bilayer thickness was measured (7.11 Å). After the manufacturing with DMLS technique, annealing in argon atmosphere is an essential process for Co-Cr metal ceramic substructures. The dentists should be familiar with the materials that are used in clinic for prosthodontics treatments.

  12. Evaluation of metal-ceramic bond characteristics of three dental Co-Cr alloys prepared with different fabrication techniques.

    Science.gov (United States)

    Wang, Hongmei; Feng, Qing; Li, Ning; Xu, Sheng

    2016-12-01

    Limited information is available regarding the metal-ceramic bond strength of dental Co-Cr alloys fabricated by casting (CAST), computer numerical control (CNC) milling, and selective laser melting (SLM). The purpose of this in vitro study was to evaluate the metal-ceramic bond characteristics of 3 dental Co-Cr alloys fabricated by casting, computer numerical control milling, and selective laser melting techniques using the 3-point bend test (International Organization for Standardization [ISO] standard 9693). Forty-five specimens (25×3×0.5 mm) made of dental Co-Cr alloys were prepared by CAST, CNC milling, and SLM techniques. The morphology of the oxidation surface of metal specimens was evaluated by scanning electron microscopy (SEM). After porcelain application, the interfacial characterization was evaluated by SEM equipped with energy-dispersive spectrometry (EDS) analysis, and the metal-ceramic bond strength was assessed with the 3-point bend test. Failure type and elemental composition on the debonding interface were assessed by SEM/EDS. The bond strength was statistically analyzed by 1-way ANOVA and Tukey honest significant difference test (α=.05). The oxidation surfaces of the CAST, CNC, and SLM groups were different. They were porous in the CAST group but compact and irregular in the CNC and SLM groups. The metal-ceramic interfaces of the SLM and CNC groups showed excellent combination compared with those of the CAST group. The bond strength was 37.7 ±6.5 MPa for CAST, 43.3 ±9.2 MPa for CNC, and 46.8 ±5.1 MPa for the SLM group. Statistically significant differences were found among the 3 groups tested (P=.028). The debonding surfaces of all specimens exhibited cohesive failure mode. The oxidation surface morphologies and thicknesses of dental Co-Cr alloys are dependent on the different fabrication techniques used. The bond strength of all 3 groups exceed the minimum acceptable value of 25 MPa recommended by ISO 9693; hence, dental Co-Cr alloy

  13. Hardening mechanism of an Ag-Pd-Cu-Au dental casting alloy

    International Nuclear Information System (INIS)

    Seol, Hyo-Joung; Kim, Gi-Chul; Son, Kuk-Hyeon; Kwon, Yong Hoon; Kim, Hyung-Il

    2005-01-01

    Age-hardening behaviour and the related microstructural changes were studied to elucidate the hardening mechanism of an Ag-Pd-Cu-Au dental casting alloy by means of hardness test, X-ray diffraction (XRD), scanning electron microscopic (SEM) observations and electron probe microanalysis (EPMA). By considering hardness test and XRD results together, it was revealed that the hardness increased during the early stage of phase transformation of α into α 1 . In the SEM photographs, two phases of matrix and particle-like structures were observed, and the precipitation of element from the matrix progressed during isothermal aging. By SEM observations and EPMA analysis, it could be supposed that the increase in hardness was caused by the diffusion and aggregation of Cu atoms from the Ag-rich α matrix containing Au and Cu in the early stage of age-hardening process, and that the decrease in hardness was caused by the progress of coarsening of Cu-rich lamellar precipitates in the later stage of the age-hardening process. The changes in the Ag-rich matrix caused both the increase and decrease in hardness, and the CuPd phase containing small amounts of Zn and Sn did not contribute to the hardness changes

  14. Microstructures, mechanical properties and corrosion resistance of the Zr−xTi (Ag) alloys for dental implant application

    Energy Technology Data Exchange (ETDEWEB)

    Cui, W.F., E-mail: cuiwf@atm.neu.edu.cn; Liu, N.; Qin, G.W.

    2016-06-15

    The Zr−xTi (Ag) alloys were designed for the application of dental implants. The microstructures of Zr−20Ti and Zr−40Ti alloy were observed using optical microscope and transmission electronic microscope. The hardness and compressive tests were performed to evaluate the mechanical properties of the Zr−xTi alloys. The electrochemical behavior of the Zr−xTi alloys with and without 6% Ag was investigated in the acidified artificial saliva containing 0.1% NaF (pH = 4). For comparison, the electrochemical behavior of cp Ti was examined in the same condition. The results show that the quenched Zr−20Ti and Zr−40Ti alloy exhibit acicular martensite microstructures containing twin substructure. They display good mechanical properties with the hardness of ∼330HV, the yield strength of ∼1000 MPa and the strain to fracture of ∼25% at room temperature. Adding 6% Ag to Zr−20Ti alloy enhances the passivity breakdown potential and the self-corrosion potential, but hardly affects the corrosion current density and the impedance modulus. 6% Ag in Zr−40Ti alloy distinctly increases pitting corrosion resistance, which is attributed the formation of thick, dense and stable passive film under the joint action of titanium and silver. In comparison with cp Ti, Zr−40Ti−6Ag alloy possesses the same good corrosion resistance in the rigorous oral environment as well as the superior mechanical properties. - Highlights: • The quenched Zr20Ti and Zr40Ti obtain acicular martensite microstructure. • Zr20Ti and Zr40Ti possess high hardness, strength and strain to fracture. • Increasing Ti content decreases corrosion current density. • Adding Ag enhances passivation breakdown potentials of Zr20Ti and Zr40Ti. • Zr40Ti6Ag has optimum mechanical properties and pitting corrosion resistance.

  15. Metallurgical and interfacial characterization of PFM Co-Cr dental alloys fabricated via casting, milling or selective laser melting.

    Science.gov (United States)

    Al Jabbari, Y S; Koutsoukis, T; Barmpagadaki, X; Zinelis, S

    2014-04-01

    Bulk and interfacial characterization of porcelain fused to metal (PFM) Co-Cr dental alloys fabricated via conventional casting, milling and selective laser melting. Three groups of metallic specimens made of PFM Co-Cr dental alloys were prepared using casting (CST), milling (MIL) and selective laser sintering (SLM). The porosity of the groups was evaluated using X-ray scans. The microstructures of the specimens were evaluated via SEM examination, EDX and XRD analysis. Vickers hardness testing was utilized to measure the hardness of the specimens. Interfacial characterization was conducted on the porcelain-covered specimens from each group to test the elemental distribution with and without the application of INmetalbond. The elemental distribution of the probed elements was assessed using EDX line profile analysis. Hardness results were statistically analyzed using one-way ANOVA and Holm-Sidak's method (α=0.05). X-ray radiography revealed the presence of porosity only in the CST group. Different microstructures were identified among the groups. Together with the γ phase matrix, a second phase, believed to be the Co3Mo phase, was also observed by SEM and subsequent XRD analysis. Cr7C3 and Cr23C6 carbides were also identified via XRD analysis in the CST and MIL groups. The hardness values were 320±12 HV, 297±5 HV and 371±10 HV, and statistically significant differences were evident among the groups. The microstructure and hardness of PFM Co-Cr dental alloys are dependent on the manufacturing technique employed. Given the differences in microstructural and hardness properties among the tested groups, further differences in their clinical behavior are anticipated. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  16. Effect of chemical composition of Ni-Cr dental casting alloys on the bonding characterization between porcelain and metal.

    Science.gov (United States)

    Huang, H-H; Lin, M-C; Lee, T-H; Yang, H-W; Chen, F-L; Wu, S-C; Hsu, C-C

    2005-03-01

    The purpose of this study was to investigate the influence of chemical composition of Ni-Cr dental casting alloys on the bonding behaviour between porcelain and metal. A three-point bending test was used to measure the fracture load of alloy after porcelain firing. A scanning electron microscope, accompanied by an energy dispersion spectrometer, was used to analyse the morphology and chemical composition of the fracture surface. An X-ray photoelectron spectrometer and glow discharge spectrometer were used to identify the structure and cross-sectional chemical composition, respectively, of oxide layers on Ni-Cr alloys after heat treatment at 990 degrees C for 5 min. Results showed that the oxide layers formed on all Ni-Cr alloys contained mainly Cr2O3, NiO, and trace MoO3. The Ni-Cr alloy with a higher Cr content had a thicker oxide layer, as well as a weaker bonding behaviour of porcelain/metal interface. The presence of Al (as Al2O3) and Be (as BeO) on the oxide layer suppressed the growth of the oxide layer, leading to a better porcelain/metal bonding behaviour. However, the presence of a small amount of Ti (as TiO2) on the oxide layer did not have any influence on the bonding behaviour. The fracture propagated along the interface between the opaque porcelain and metal, and exhibited an adhesive type of fracture morphology.

  17. Assessment of corrosion resistance of cast cobalt- and nickel-chromium dental alloys in acidic environments.

    Science.gov (United States)

    Mercieca, Sven; Caligari Conti, Malcolm; Buhagiar, Joseph; Camilleri, Josette

    2018-01-01

    The aim of this study was to compare the degradation resistance of nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) alloys used as a base material for partial dentures in contact with saliva. Wiron® 99 and Wironit Extra-Hard® were selected as representative casting alloys for Ni-Cr and Co-Cr alloys, respectively. The alloys were tested in contact with deionized water, artificial saliva and acidified artificial saliva. Material characterization was performed by X-ray diffractometry (XRD) and microhardness and nanohardness testing. The corrosion properties of the materials were then analyzed using open circuit potential analysis and potentiodynamic analysis. Alloy leaching in solution was assessed by inductively coupled plasma mass spectrometry techniques. Co-Cr alloy was more stable than the Ni-Cr alloy in all solutions tested. Leaching of nickel and corrosion attack was higher in Ni-Cr alloy in artificial saliva compared with the acidified saliva. The corrosion resistance of the Co-Cr alloy was seen to be superior to that of the Ni-Cr alloy, with the former exhibiting a lower corrosion current in all test solutions. Microstructural topographical changes were observed for Ni-Cr alloy in contact with artificial saliva. The Ni-Cr alloy exhibited microstructural changes and lower corrosion resistance in artificial saliva. The acidic changes did not enhance the alloy degradation. Ni-Cr alloys are unstable in solution and leach nickel. Co-Cr alloys should be preferred for clinical use.

  18. Binar Sort: A Linear Generalized Sorting Algorithm

    OpenAIRE

    Gilreath, William F.

    2008-01-01

    Sorting is a common and ubiquitous activity for computers. It is not surprising that there exist a plethora of sorting algorithms. For all the sorting algorithms, it is an accepted performance limit that sorting algorithms are linearithmic or O(N lg N). The linearithmic lower bound in performance stems from the fact that the sorting algorithms use the ordering property of the data. The sorting algorithm uses comparison by the ordering property to arrange the data elements from an initial perm...

  19. A Comparative Analysis of the Corrosive Effect of Artificial Saliva of Variable pH on DMLS and Cast Co-Cr-Mo Dental Alloy.

    Science.gov (United States)

    Puskar, Tatjana; Jevremovic, Danimir; Williams, Robert J; Eggbeer, Dominic; Vukelic, Djordje; Budak, Igor

    2014-09-11

    Dental alloys for direct metal laser sintering (DMLS) are available on the market today, but there is little scientific evidence reported on their characteristics. One of them is the release of ions, as an indicator of the corrosion characteristics of a dental alloy. Within this research, the difference in the elution of metals from DMLS and cast (CM) samples of Co-Cr-Mo dental alloy in saliva-like medium of three different pH was examined by inductively-coupled plasma mass spectrometry (ICP-MS). The obtained results show that the metal elution in artificial saliva from the DMLS alloy was lower than the elution from the CM alloy. The release of all investigated metal ions was influenced by the acidity, both from the DMLS and CM alloy, throughout the investigated period of 30 days. The change in acidity from a pH of 6.8 to a pH of 2.3 for the cast alloy led to a higher increase of the elution of Co, Cr and Mo from CM than from the DMLS alloy. The greatest release out of Co, Cr and Mo was for Co for both tested alloys. Further, the greatest release of all ions was measured at pH 2.3. In saliva of pH 2.3 and pH 4.5, the longer the investigated period, the higher the difference between the total metal ion release from the CM and DMLS alloys. Both alloys showed a safe level of elution according to the ISO definition in all investigated acidic environments.

  20. A Comparative Analysis of the Corrosive Effect of Artificial Saliva of Variable pH on DMLS and Cast Co-Cr-Mo Dental Alloy

    Directory of Open Access Journals (Sweden)

    Tatjana Puskar

    2014-09-01

    Full Text Available Dental alloys for direct metal laser sintering (DMLS are available on the market today, but there is little scientific evidence reported on their characteristics. One of them is the release of ions, as an indicator of the corrosion characteristics of a dental alloy. Within this research, the difference in the elution of metals from DMLS and cast (CM samples of Co-Cr-Mo dental alloy in saliva-like medium of three different pH was examined by inductively-coupled plasma mass spectrometry (ICP-MS. The obtained results show that the metal elution in artificial saliva from the DMLS alloy was lower than the elution from the CM alloy. The release of all investigated metal ions was influenced by the acidity, both from the DMLS and CM alloy, throughout the investigated period of 30 days. The change in acidity from a pH of 6.8 to a pH of 2.3 for the cast alloy led to a higher increase of the elution of Co, Cr and Mo from CM than from the DMLS alloy. The greatest release out of Co, Cr and Mo was for Co for both tested alloys. Further, the greatest release of all ions was measured at pH 2.3. In saliva of pH 2.3 and pH 4.5, the longer the investigated period, the higher the difference between the total metal ion release from the CM and DMLS alloys. Both alloys showed a safe level of elution according to the ISO definition in all investigated acidic environments.

  1. In vitro corrosion of dental Au-based casting alloys in polyvinylpyrrolidone-iodine solution.

    Science.gov (United States)

    Takasusuki, Norio; Ida, Yusuke; Hirose, Yukito; Ochi, Morio; Endo, Kazuhiko

    2013-01-01

    The corrosion and tarnish behaviors of two Au-based casting alloys (ISO type 1 and type 4 Au alloys) and their constituent pure metals, Au, Ag, Cu, Pt, and Pd in a polyvinylpyrrolidone-iodine solution were examined. The two Au alloys actively corroded, and the main anodic reaction for both was dissolution of Au as AuI₂(-). The amount of Au released from the ISO type 1 Au alloy was significantly larger than that from the ISO type 4 Au alloy (Palloy exhibited higher susceptibility to tarnishing than the type 4 alloy. The corrosion forms of the two Au alloys were found to be completely different, i.e., the type 1 alloy exhibited the corrosion attack over the entire exposed surface with a little irregularity whereas the type 4 alloy exhibited typical intergranular corrosion, which was caused by local cells produced by segregation of Pd and Pt.

  2. Mn-coatings on the micro-pore formed Ti-29Nb-xHf alloys by RF-magnetron sputtering for dental applications

    Science.gov (United States)

    Park, Seon-Yeong; Choe, Han-Cheol

    2018-02-01

    In this study, Mn-coatings on the micro-pore formed Ti-29Nb-xHf alloys by RF-magnetrons sputtering for dental applications were studied using different experimental techniques. Mn coating films were formed on Ti-29Nb-xHf alloys by a radio frequency magnetron sputtering technique for 0, 1, 3, and 5 min at 45 W. The microstructure, composition, and phase structure of the coated alloys were examined by optical microscopy, field emission scanning electron microscopy, X-ray diffraction, and energy-dispersive X-ray spectroscopy. The microstructure of Ti-29Nb alloy showed α" phase in the needle-like structure and Ti-29Nb-15Hf alloy showed β phase in the equiaxed structure. As the sputtering time increased, the circular particles of Mn coatings on the Ti-29Nb alloy increased at inside and outside surfaces. As the sputtering time increased, [Mn + Ca/P] ratio of the plasma electrolytic oxidized films in Ti- 29Nb-xHf alloys increased. The corrosion potential (Ecorr) of Mn coatings on the Ti-29Nb alloy showed higher than that of Mn coatings on the Ti-29Nb-15Hf alloy. The passive current density (Ipass) of the Mn coating on the Ti-29Nb alloy and Mn coatings on the Ti-29Nb-15Hf alloy was less noble than the non-Mn coated Ti-29Nb and Ti-29Nb-15Hf alloys surface.

  3. SU-C-BRC-05: Monte Carlo Calculations to Establish a Simple Relation of Backscatter Dose Enhancement Around High-Z Dental Alloy to Its Atomic Number

    Energy Technology Data Exchange (ETDEWEB)

    Utsunomiya, S; Kushima, N; Katsura, K; Tanabe, S; Hayakawa, T; Sakai, H; Yamada, T; Takahashi, H; Abe, E; Wada, S; Aoyama, H [Niigata University, Niigata (Japan)

    2016-06-15

    Purpose: To establish a simple relation of backscatter dose enhancement around a high-Z dental alloy in head and neck radiation therapy to its average atomic number based on Monte Carlo calculations. Methods: The PHITS Monte Carlo code was used to calculate dose enhancement, which is quantified by the backscatter dose factor (BSDF). The accuracy of the beam modeling with PHITS was verified by comparing with basic measured data namely PDDs and dose profiles. In the simulation, a high-Z alloy of 1 cm cube was embedded into a tough water phantom irradiated by a 6-MV (nominal) X-ray beam of 10 cm × 10 cm field size of Novalis TX (Brainlab). The ten different materials of high-Z alloys (Al, Ti, Cu, Ag, Au-Pd-Ag, I, Ba, W, Au, Pb) were considered. The accuracy of calculated BSDF was verified by comparing with measured data by Gafchromic EBT3 films placed at from 0 to 10 mm away from a high-Z alloy (Au-Pd-Ag). We derived an approximate equation to determine the relation of BSDF and range of backscatter to average atomic number of high-Z alloy. Results: The calculated BSDF showed excellent agreement with measured one by Gafchromic EBT3 films at from 0 to 10 mm away from the high-Z alloy. We found the simple linear relation of BSDF and range of backscatter to average atomic number of dental alloys. The latter relation was proven by the fact that energy spectrum of backscatter electrons strongly depend on average atomic number. Conclusion: We found a simple relation of backscatter dose enhancement around high-Z alloys to its average atomic number based on Monte Carlo calculations. This work provides a simple and useful method to estimate backscatter dose enhancement from dental alloys and corresponding optimal thickness of dental spacer to prevent mucositis effectively.

  4. [Studies on high temperature oxidation of noble metal alloys for dental use. (III) On high temperature oxidation resistance of noble metal alloys by adding small amounts of alloying elements. (author's transl)].

    Science.gov (United States)

    Ohno, H

    1976-11-01

    The previous report pointed out the undesirable effects of high temperature oxidation on the casting. The influence of small separate additions of Zn, Mg, Si, Be and Al on the high temperature oxidation of the noble metal alloys was examined. These alloying elements were chosen because their oxide have a high electrical resistivity and they have much higher affinity for oxygen than Cu. The casting were oxidized at 700 degrees C for 1 hour in air. The results obtained were as follows: 1. The Cu oxides are not observed on the as-cast surface of noble metal alloys containing small amounts of Zn, Mg, Si, Be, and Al. The castings have gold- or silver-colored surface. 2. After heating of the unpolished and polished castings, the additions of Si, Be and Al are effective in preventing oxidation of Cu in the 18 carats gold alloys. Especially the golden surface is obtained by adding Be and Al. But there is no oxidation-resistance on the polished castings in the alloys containing Zn and Mg. 3. The zinc oxide film formed on the as-cast specimen is effective in preventing of oxidation Cu in 18 carats gold alloys. 4. It seems that the addition of Al is most available in dental application.

  5. Mg-containing hydroxyapatite coatings on Ti-6Al-4V alloy for dental materials

    Science.gov (United States)

    Yu, Ji-Min; Choe, Han-Cheol

    2018-02-01

    In this study, Mg-containing hydroxyapatite coatings on Ti-6A1-4 V alloy for dental materials were researched using various experimental instruments. Plasma electrolytic oxidation (PEO) was performed in electrolytes containing Mg (symbols of specimens: CaP, 5M%, 10M%, and 20M%) at 280 V for 3 min. The electrolyte used for PEO was produced by mixing Ca(CH3COO)2·H2O, C3H7NaCaO6P, and MgCl2·6H2O. The phases and composition of the oxide films were evaluated by X-ray diffraction and field-emission scanning electron microscopy with energy dispersive X-ray spectrometry. The irregularity of the surface, pore size, and number of pores decreased as the Mg concentration increased. The ratio of the areas occupied and not occupied by pores decreased as the Mg concentration increased, with the numbers of both large and small pores decreasing with increasing Mg concentration. The number of particles on the internal surfaces of pores was increased as the Mg content increased. Mg content of all samples containing Mg ions showed higher in the pore outside than that of pore inside, whereas the Ca content was higher inside the pores. The P content of samples with the addition of Mg ions showed higher values inside the pores than outside. The Ca/P and [Mg + Ca]/P molar ratios in the PEO films decreased with Mg content. The crystallite size of anatase was increased with increasing Mg concentration in the solution.

  6. [Effect of heat treatment on the structure of a Cu-Zn-Al-Ni system dental alloy].

    Science.gov (United States)

    Guastaldi, A C; Adorno, A T; Beatrice, C R; Mondelli, J; Ishikiriama, A; Lacefield, W

    1990-01-01

    This article characterizes the structural phases present in the copper-based metallic alloy system "Cu-Zn-Al-Ni" developed for dental use, and relates those phases to other properties. The characterization was obtained after casting (using the lost wax process), and after heat treatment. In order to obtain better corrosion resistance by changing the microstructure, the castings were submitted to 30, 45 and 60 minutes of heat treatment at the following temperatures: 750 degrees C, 800 degrees C, and 850 degrees C. The various phases were analyzed using X-ray diffraction and scanning electron microscopy (SEM). The results after heat treatment showed a phase (probably Cu3Al), that could be responsible for the improvement in the alloy's resistance to corrosion as compared to the as-cast structure.

  7. Biocompatibility effects of indirect exposure of base-metal dental casting alloys to a human-derived three-dimensional oral mucosal model.

    Science.gov (United States)

    McGinley, Emma Louise; Moran, Gary P; Fleming, Garry J P

    2013-11-01

    The study employed a three-dimensional (3D) human-derived oral mucosal model to assess the biocompatibility of base-metal dental casting alloys ubiquitous in fixed prosthodontic and orthodontic dentistry. Oral mucosal models were generated using primary human oral keratinocyte and gingival fibroblast cells seeded onto human de-epidermidised dermal scaffolds. Nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) base-metal alloy immersion solutions were exposed to oral mucosal models for increasing time periods (2-72h). Analysis methodologies (histology, viable cell counts, oxidative stress, cytokine expression and toxicity) were performed following exposure. Ni-based alloy immersion solutions elicited significantly decreased cell viability (P0.4755) or cellular toxicity (Pcasting alloys through discriminatory experimental parameters. Increasing incidences of Ni hypersensitivity in the general population warrants serious consideration from dental practitioners and patients alike where fixed prosthodontic/orthodontic dental treatments are the treatment modality involved. The novel and analytical oral mucosal model has the potential to significantly contribute to the advancement of reproducible dental medical device and dental material appraisals. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Effect of different oxidation treatments on the bonding strength of new dental alloys

    International Nuclear Information System (INIS)

    Lee, Sang-Bae; Lee, Ju-hye; Kim, Woong-Chul; Oh, Sae-Yoon; Kim, Kyoung-Nam; Kim, Ji-Hwan

    2009-01-01

    The influences of heat treatment and addition of a small amount of base metal (In, Sn, and Ir) for oxidation in Au-Pt-based alloy were investigated by electron spectroscopy and scanning electron microscopy. Au-Pt-based alloys were prepared by argon-arc melting furnace and then they are heat treated. Oxidation on alloy was significantly affected by addition of base metal (In and Sn) and heat treatment. The bond strength of the alloys was not dependent on the changing heat treatment. These results indicated that the Sn and In could be effective as oxidation elements for porcelain bonding to gold alloys.

  9. Potentiodynamic polarization study of the corrosion behavior of palladium-silver dental alloys.

    Science.gov (United States)

    Sun, Desheng; Brantley, William A; Frankel, Gerald S; Heshmati, Reza H; Johnston, William M

    2018-04-01

    Although palladium-silver alloys have been marketed for over 3 decades for metal-ceramic restorations, understanding of the corrosion behavior of current alloys is incomplete; this understanding is critical for evaluating biocompatibility and clinical performance. The purpose of this in vitro study was to characterize the corrosion behavior of 3 representative Pd-Ag alloys in simulated body fluid and oral environments and to compare them with a high-noble Au-Pd alloy. The study obtained values of important electrochemical corrosion parameters, with clinical relevance, for the rational selection of casting alloys. The room temperature in vitro corrosion characteristics of the 3 Pd-Ag alloys and the high-noble Au-Pd alloy were evaluated in 0.9% NaCl, 0.09% NaCl, and Fusayama solutions. After simulated porcelain firing heat treatment, 5 specimens of each alloy were immersed in the electrolytes for 24 hours. For each specimen, the open-circuit potential (OCP) was first recorded, and linear polarization was then performed from -20 mV to +20 mV (versus OCP) at a rate of 0.125 mV/s. Cyclic polarization was subsequently performed on 3 specimens of each alloy from -300 mV to +1000 mV and back to -300 mV (versus OCP) at a scanning rate of 1 mV/s. The differences in OCP and corrosion resistance parameters (zero-current potential and polarization resistance) among alloys and electrolyte combinations were compared with the 2-factor ANOVA (maximum-likelihood method) with post hoc Tukey adjustments (α=.05). The 24-hour OCPs and polarization resistance values of the 3 Pd-Ag alloys and the Au-Pd alloy were not significantly different (P=.233 and P=.211, respectively) for the same electrolyte, but significant differences were found for corrosion test results in different electrolytes (Palloy and electrolyte (P=.249 and P=.713, respectively). The 3 Pd-Ag silver alloys appeared to be resistant to chloride ion corrosion, and passivation and de-alloying were identified for these

  10. Comparison of the microstructure and phase stability of as-cast, CAD/CAM and powder metallurgy manufactured Co-Cr dental alloys.

    Science.gov (United States)

    Li, Kai Chun; Prior, David J; Waddell, J Neil; Swain, Michael V

    2015-12-01

    The objective of this study was to identify the different microstructures produced by CC, PM and as-cast techniques for Co-Cr alloys and their phase stability following porcelain firings. Three bi-layer porcelain veneered Co-Cr specimens and one monolithic Co-Cr specimen of each alloy group [cast, powder metallurgy (PM), CAD/CAM (CC)] were manufactured and analyzed using electron backscatter diffraction (EBSD), energy dispersive spectrometry (EDS) and X-ray diffraction (XRD). Specimens were treated to incremental numbers of porcelain firings (control 0, 5, 15) with crystallographic data, grain size and chemical composition subsequently obtained and analyzed. EBSD datasets of the cast alloy indicated large grains >200 μm whereas PM and CC alloy consisted of mean arithmetic grain sizes of 29.6 μm and 19.2 μm respectively. XRD and EBSD results both indicated the highest increase in hcp content (>13vol%) for cast Co-Cr alloy after treatment with porcelain firing while PM and CC indicated .05) was observed in CC. EDS line scans indicated an increase in Cr content at the alloy surface after porcelain firing treatment for all three alloys. PM and CC produced alloy had superior fcc phase stability after porcelain firings compared to a traditional cast alloy. It is recommended that PM and CC alloys be used for porcelain-fused-to-metal restorations. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  11. Effect of nitrogen on the microstructure and mechanical properties of Co-33Cr-9W alloys prepared by dental casting.

    Science.gov (United States)

    Yamanaka, Kenta; Mori, Manami; Torita, Yasuhiro; Chiba, Akihiko

    2018-01-01

    The effect of nitrogen concentration on the mechanical properties of Co-33Cr-9W alloy dental castings fabricated using the "high-Cr and high-N" concept was investigated. Microstructural analysis was performed on the alloys, and findings were discussed in relation to the mechanical properties. Owing to their high nitrogen concentrations (0.25-0.35wt%), all alloys prepared exhibited face-centered cubic (fcc) γ-phase matrices with a-few-millimeter grains consisting of dendritic substructures. Strain-induced martensitic transformations to produce hexagonal close-packed (hcp) ε-phases were not identified under tensile deformation. The precipitation of the intermetallic σ-phase was identified at the interdendritic regions where solidification segregation of Cr and W occurred. The size and chemical composition of this σ-phase did not vary with the bulk nitrogen concentration. Adding nitrogen to the alloys did not alter their tensile yield stress or Vickers hardness values significantly, suggesting that the nitrogen strengthening effect is affected by the manufacturing route as well as local chemistry that is involved in the microstructural evolution during solidification. The tensile ductility, on the other hand, increased with an increase in nitrogen concentration; the alloy with 0.35wt% nitrogen exhibited 21% elongation with a high 0.2% proof stress (589MPa). This significant improvement in ductility was likely caused by the reduction in the amount of σ-phase precipitates at the interdendritic regions following the addition of nitrogen. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Microstructural evidence of presence of beryllium in Ni-Cr alloys for dental prostheses; Evidencia microestrutural da presenca de berilio em ligas Ni-Cr para proteses dentarias

    Energy Technology Data Exchange (ETDEWEB)

    Alkmin, L.B.; Nunes, C.A., E-mail: lba@ppgem.eel.usp.b [Universidade de Sao Paulo (EEL/USP), Lorena, SP (Brazil). Escola de Engenharia; Coelho, G.C. [Centro Universitario de Volta Redonda (UNIFOA), Volta Redonda, RJ (Brazil); Santos, C. [Protmat Materiais Avancados, Guaratingueta, SP (Brazil)

    2010-07-01

    This study aimed to characterize the microstructure of commercial Ni-Cr alloys for dental prosthesis, with special focus on those containing Be. For this, the materials were characterized in terms of chemical composition, phases and melting point temperature. The following techniques were used: X-ray fluorescence, ICP-OES, scanning electron microscopy, electron probe microanalysis, X-ray diffraction and differential thermal analysis. The results clearly showed the presence of a typical eutectic, formed by the Ni{sub ss} and NiBe phases in those alloys containing Be, which can be considered a 'fingerprint' of the presence of this element in these alloys. (author)

  13. Electrochemical behavior of 45S5 bioactive ceramic coating on Ti6Al4V alloy for dental applications

    Science.gov (United States)

    Machado López, M. M.; Espitia Cabrera, M. I.; Faure, J.; Contreras García, M. E.

    2016-04-01

    Titanium and its alloys are widely used as implant materials because of their mechanical properties and non-toxic behavior. Unfortunately, they are not bioinert, which means that they can release ions and can only fix the bone by mechanical anchorage, this can lead to the encapsulation of dense fibrous tissue in the body. The bone fixation is required in clinical conditions treated by orthopedic and dental medicine. The proposal is to coat metallic implants with bioactive materials to establish good interfacial bonds between the metal substrate and bone by increasing bioactivity. Bioactive glasses, ceramics specifically 45 S5 Bioglass, have drawn attention as a serious functional biomaterial because osseointegration capacity. The EPD method of bioglass gel precursor was proposed in the present work as a new method to obtain 45S5/Ti6A14V for dental applications. The coatings, were thermally treated at 700 and 800°C and presented the 45 S5 bioglass characteristic phases showing morphology and uniformity with no defects, quantification percentages by EDS of Si, Ca, Na, P and O elements in the coating scratched powders, showed a good proportional relationship demonstrating the obtention of the 45S5 bioglass. The corrosion tests were carried out in Hank's solution. By Tafel extrapolation, Ti6Al4V alloy showed good corrosion resistance in Hank's solution media, by the formation of a passivation layer on the metal surface, however, in the system 45S5/Ti6Al4V there was an increase in the corrosion resistance; icon-, Ecorr and corrosion rate decreased, the mass loss and the rate of release of ions, were lower in this system than in the titanium alloy without coating.

  14. Immunological parameters of dental alloy corrosion; A study of gingival inflammation after placement of stainless steel crown

    Directory of Open Access Journals (Sweden)

    Ratna Indriyanti

    2008-11-01

    Full Text Available The dental alloy is widely used in many fields of dentistry as a restoration material, orthodontic, prosthodontic, oral surgery and endodontic treatments. Naturally, most of the metallic materials without exception to stainless steel alloy will experience a process of corrosion in a form of electrochemical reaction to achieve thermodynamic equilibrium. The corrosion process in the oral cavity is due to the reaction of metal with saliva as an oral cavity electrolyte fluid. SSC has preformed restoration material conform with dental anatomy, manufactured from stainless steel alloy which is formable and adaptable to the teeth. Stainless Steel Crown generally made of austenitic stainless steel 18/8 of AISI 304 group contain chrome 18% and Nickel 8%, can be used as a restoration for teeth with excessive caries, crown fracture, email hypoplasia, or restoration after endodontic treatment. The toxic effect of Ni+2 released due to corrosion process may cause an inflammation of the gingiva and periodontal tissue. Laboratorically this condition indicated by the expression of pro-inflammation cytokines as immunological parameters such as IL-6, IL-8, TNF and IL-1β whose main role is to initiate and enhance any inflammation responses. The presence of pro-inflammation cytokines can be detected as soon as 1 hour after placement of SSC by examination of gingival crevicular fluid (GCF by ELISA technique. The magnitude of the toxic effect depends on corrosion rate and ions release which is influenced by metal chemical composition, environment temperature and pH, metal wear due to abrasion and friction, soldering if any, and elongation of the metal. Conclusion: The release of Ni+2 during corrosion process after placement of SSC cause gingival inflammation which is indicated by the change of the immunological parameters.

  15. An overview of NiTi shape memory alloy: Corrosion resistance and antibacterial inhibition for dental application

    Energy Technology Data Exchange (ETDEWEB)

    Fadlallah, Sahar A., E-mail: sahar.fadlallah@yahoo.com [Materials and Corrosion Lab. (MCL), Faculty of Science, Taif University, Taif (Saudi Arabia); Chemistry Department, Faculty of Science, Cairo University, Cairo (Egypt); El-Bagoury, Nader [Materials and Corrosion Lab. (MCL), Faculty of Science, Taif University, Taif (Saudi Arabia); Casting Technology Lab., Manufacturing Technology Dept., CMRDI, P.O. Box 87, Helwan, Cairo (Egypt); Gad El-Rab, Sanaa M.F. [Biotechnology Department, Faculty of Science, Taif University, Taif (Saudi Arabia); Botany Department, Faculty of Science, Asuit University, Asuit (Egypt); Ahmed, Rasha A. [Materials and Corrosion Lab. (MCL), Faculty of Science, Taif University, Taif (Saudi Arabia); Forensic Chemistry Laboratories, Medico Legal Department, Ministry of Justice, Cairo (Egypt); El-Ousamii, Ghaida [Materials and Corrosion Lab. (MCL), Faculty of Science, Taif University, Taif (Saudi Arabia)

    2014-01-15

    Highlights: • Evaluate the corrosion resistance of NiTi alloy by using electrochemical techniques. • Estimate the Antibacterial inhibition rate of NiTi alloy. • Assessment the mechanical properties of NiTi from the hardness measurements. • Comparsion the microstructures of cast NiTi with Ti, this indicate the role of Ni to change the behavior of alloy in oral environment. • Advise drinking green tea in small quantities in small quantities in the event of present NiTi alloy in the oral cavity. • Recommendation to use NiTi for dental application. -- Abstract: Nowadays, Nickel–titanium nearly equiatomic is considered as one of the best biomaterials. The aim of the present work deals with the evolution of the electrochemical behavior of NiTi in simulated oral environment. The hardness, microstructures corrosion resistance and antibacterial performance of NiTi alloy were compared with pure titanium. The hardness of NiTi is twice the hardness of pure titanium. Electrochemical techniques were used to detect the corrosion resistance of both biomaterials in Hank’s solution containing (−)-epigallocatechin gallate (EGCG) which used to simulate the oral environment. In the physiological solution selected for the present study, the impedance spectroscopy (EIS) results showed that EGCG sharply increase the corrosion resistance of NiTi from 129 kΩ cm{sup 2} to 1.10 T Ω cm{sup 2} while slowly increase the corrosion resistance of pure titanium from 9.4 kΩ cm{sup 2} to 11.3 kΩ cm{sup 2} during the duration time of immersion at 37 °C. The plate-counting method was used to evaluate the antibacterial performance against Staphylococcus aureus (ATCC 6538). Among the two specimens of biomaterials studied, the antibacterial performance results revealed that the NiTi alloy is better than the pure titanium. The morphology and chemical structure of NiTi and Ti samples were systematically investigated by scanning electron microscope (SEM) and energy dispersive X

  16. An overview of NiTi shape memory alloy: Corrosion resistance and antibacterial inhibition for dental application

    International Nuclear Information System (INIS)

    Fadlallah, Sahar A.; El-Bagoury, Nader; Gad El-Rab, Sanaa M.F.; Ahmed, Rasha A.; El-Ousamii, Ghaida

    2014-01-01

    Highlights: • Evaluate the corrosion resistance of NiTi alloy by using electrochemical techniques. • Estimate the Antibacterial inhibition rate of NiTi alloy. • Assessment the mechanical properties of NiTi from the hardness measurements. • Comparsion the microstructures of cast NiTi with Ti, this indicate the role of Ni to change the behavior of alloy in oral environment. • Advise drinking green tea in small quantities in small quantities in the event of present NiTi alloy in the oral cavity. • Recommendation to use NiTi for dental application. -- Abstract: Nowadays, Nickel–titanium nearly equiatomic is considered as one of the best biomaterials. The aim of the present work deals with the evolution of the electrochemical behavior of NiTi in simulated oral environment. The hardness, microstructures corrosion resistance and antibacterial performance of NiTi alloy were compared with pure titanium. The hardness of NiTi is twice the hardness of pure titanium. Electrochemical techniques were used to detect the corrosion resistance of both biomaterials in Hank’s solution containing (−)-epigallocatechin gallate (EGCG) which used to simulate the oral environment. In the physiological solution selected for the present study, the impedance spectroscopy (EIS) results showed that EGCG sharply increase the corrosion resistance of NiTi from 129 kΩ cm 2 to 1.10 T Ω cm 2 while slowly increase the corrosion resistance of pure titanium from 9.4 kΩ cm 2 to 11.3 kΩ cm 2 during the duration time of immersion at 37 °C. The plate-counting method was used to evaluate the antibacterial performance against Staphylococcus aureus (ATCC 6538). Among the two specimens of biomaterials studied, the antibacterial performance results revealed that the NiTi alloy is better than the pure titanium. The morphology and chemical structure of NiTi and Ti samples were systematically investigated by scanning electron microscope (SEM) and energy dispersive X-ray analysis (EDX). The

  17. Effects of shot-peening and atmospheric-pressure plasma on aesthetic improvement of Ti-Nb-Ta-Zr alloy for dental applications

    Science.gov (United States)

    Miura-Fujiwara, Eri; Suzuki, Yuu; Ito, Michiko; Yamada, Motoko; Matsutake, Sinpei; Takashima, Seigo; Sato, Hisashi; Watanabe, Yoshimi

    2018-01-01

    Ti and Ti alloys are widely used for biomedical applications such as artificial joints and dental devices because of their good mechanical properties and biochemical compatibility. However, dental devices made of Ti and Ti alloys do not have the same color as teeth, so they are inferior to ceramics and polymers in terms of aesthetic properties. In a previous study, Ti-29Nb-13Ta-4.6Zr was coated with a white Ti oxide layer by heat treatment to improve its aesthetic properties. Shot-peening is a severe plastic deformation process and can introduce a large shear strain on the peened surface. In this study, the effects of shot-peening and atmospheric-pressure plasma on Ti-29Nb-13Ta-4.6Zr were investigated to form a white layer on the surface for dental applications.

  18. Selective Laser Melting Technique of Co-Cr Dental Alloys: A Review of Structure and Properties and Comparative Analysis with Other Available Techniques.

    Science.gov (United States)

    Koutsoukis, Theodoros; Zinelis, Spiros; Eliades, George; Al-Wazzan, Khalid; Rifaiy, Mohammed Al; Al Jabbari, Youssef S

    2015-06-01

    The aim of this study was to review the effect of selective laser melting (SLM) procedure on the properties of dental structures made of Co-Cr alloys and to evaluate its quality and compare it to those produced by conventional casting and milling fabrication techniques. A computerized database search using PubMed and Scopus was conducted for peer-reviewed scientific research studies regarding the use of SLM in Co-Cr dental alloys with no restrictions for publication years. The search engines provided hundreds of results, and only 48 scientific research papers, case studies, or literature reviews were considered relevant for this review. The innovative manufacturing concept of SLM offers many advantages compared with casting and milling fabrication techniques. SLM provides different microstructure from casting and milling with minimal internal porosity and internal fitting, marginal adaptation, and comparable bond strength to porcelain. Mechanical and electrochemical properties of SLM structures are enhanced compared to cast, while clinical longevity of single-metal ceramic crowns is comparable to Au-Pt dental alloy. The SLM technique provides dental prosthetic restorations more quickly and less expensively without compromising their quality compared with restorations prepared by casting and milling techniques. The current SLM devices provide metallic restorations made of Co-Cr alloys for removable and fixed partial dentures without compromising the alloy or restoration properties at a fraction of the time and cost, showing great potential to replace the aforementioned fabrication techniques in the long term; however, further clinical studies are essential to increase the acceptance of this technology by the worldwide dental community. © 2015 by the American College of Prosthodontists.

  19. Nanotube formation and morphology change of Ti alloys containing Hf for dental materials use

    International Nuclear Information System (INIS)

    Jeong, Yong-Hoon; Lee, Kang; Choe, Han-Cheol; Ko, Yeong-Mu; Brantley, William A.

    2009-01-01

    In this paper, Ti-Hf (10, 20, 30 and 40 wt.%) alloys were prepared by arc melting, and subjected to heat treatment for 24 h at 1000 o C in an argon atmosphere. Formation of surface nanotubes was achieved by anodizing a Ti-Hf alloy in 1.0 M H 3 PO 4 electrolytes with small amounts of NaF at room temperature. Microstructures of the alloys and nanotube morphology were examined by field-emission scanning electron microscopy (FE-SEM) and X-ray diffraction (XRD). The homogenized Ti-Hf alloys had a needle-like microstructure of α phase, and nanotubes formed on Ti-xHf alloys had the anatase phase after treatment that promoted crystallization. Uniform nanotubes formed for Hf contents up to 20 wt.%. Irregular nanotubes formed on the Ti-30Hf and Ti-40Hf alloys. The structure of the irregular layers on the Ti-30Hf and Ti-40Hf alloys had nanotubes of two sizes. Increasing the Hf content in Ti led to the formation of nanotubes with more narrow size. The pores in the nanotubes typically had a diameter ranging from 80-120 nm and a length of approximately 1.7 μm. It is concluded that nanotube morphology on Ti-Hf alloys can controlled by varying the amount of Hf.

  20. Dental implant suprastructures using cobalt-chromium alloy compared with gold alloy framework veneered with ceramic or acrylic resin: a retrospective cohort study up to 18 years.

    Science.gov (United States)

    Teigen, Kyrre; Jokstad, Asbjørn

    2012-07-01

    An association between the long-term success and survival of implant-supported prostheses as a function of biomaterial combinations has not been established. The use of cast cobalt-chromium for the suprastructure framework may be an alternative to the conventional approach of using type 3 gold alloys. A retrospective chart audit of all patients who had received implant-supported fixed dental prostheses (FDP) before 1996 was identified in a private practice clinic. Data were recorded for FDPs made from four combinations of alloy frameworks and veneering material, i.e. type 3 gold and cobalt-chromium with ceramic or prefabricated acrylic teeth. The extracted data from the charts were subjected to explorative statistical tests including Kaplan-Meier survival analyses. Patients (n=198) with 270 short and extensive FDPs supported entirely by 1117 implants were identified. The average follow-up observation periods varied between 4 and 220 months, with an average of 120 months. The success and survival, as well as event rates and types of biological and technical complications, were similar for implant-supported FDPs using cobalt-chromium and type 3 gold alloy frameworks veneered with ceramics or prefabricated acrylic teeth. An influence of the suprastructure biomaterial combination on the clinical performance of the individual supporting implants could not be established. Implant-supported FDPs made from type 3 gold or cobalt-chromium frameworks and veneered with ceramic or prefabricated acrylic teeth demonstrate comparable clinical performance. The biomaterial combinations do not appear to influence the success or survival of the individual implants. © 2011 John Wiley & Sons A/S.

  1. Análisis del comportamiento mecánico de una aleación Ni-Cr-Mo para pilares dentales/Analysis of Mechanical Behavior of Ni-Cr-Mo alloy for Dental Abutments

    Directory of Open Access Journals (Sweden)

    Luis Alberto Laguado Villamizar

    2012-12-01

    Full Text Available El presente estudio caracteriza una aleación aplicable al diseño de pilares para implantes dentales. Se propone un material biocompatible y de alta resistencia mecánica como alternativa a las aleaciones de Titanio, disminuyendo los costos de materia prima y procesamiento. Se realizan pruebas mecánicas de tracción y de compresión a la aleación de Ni-Cr-Mo, posteriormente se realiza modelado 3D y simulación de sus propiedades mecánicas por medio de análisis de elementos finitos. Como resultado se obtiene que el material disminuye su resistencia mecánica después del proceso de fundición empleado. El modelo de simulación es válido para análisis de resistencia en pilares dentales.This study presents the characterization of a dental implant alloy for abutments. It proposes a biocompatible material and high mechanical resistance as an alternative to Titanium alloys, lowering costs of raw materials and processing. Mechanical testing of the Ni-Cr-Mo alloy and subsequently perform simulations of its mechanical properties by means of finite element analysis. As a result is obtained that the material reduces its mechanical strength after the casting for electric induction molding process. The simulation model is valid to make analysis of resistance to this type of dental devices.

  2. Verification of counting sort and radix sort

    NARCIS (Netherlands)

    C.P.T. de Gouw (Stijn); F.S. de Boer (Frank); J.C. Rot (Jurriaan)

    2016-01-01

    textabstractSorting is an important algorithmic task used in many applications. Two main aspects of sorting algorithms which have been studied extensively are complexity and correctness. [Foley and Hoare, 1971] published the first formal correctness proof of a sorting algorithm (Quicksort). While

  3. Fractal study of Ni-Cr-Mo alloy for dental applications: effect of beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Eftekhari, Ali

    2003-12-30

    Different Ni-based alloys with various compositions were prepared by varying the amounts of beryllium. Effect of the amount of beryllium added to the alloy on its corrosion in an electrolyte solution of artificial saliva was investigated. Fractal dimension was used as a quantitative factor for surface analysis of the alloys before and after storage in the artificial salvia. The fractal dimensions of the electrode surfaces were determined by means of the most reliable method in this context viz. time dependency of the diffusion-limited current for a system involving 'diffusion towards electrode surface'. The results showed that increase of the beryllium amount in the alloy composition significantly increases the alloy corrosion. It is accompanied by increase of the fractal dimension and roughness of the electrode surface, whereas a smooth and shiny surface is required for dentures. From the methodology point of view, the approach utilized for fractal analysis of the alloy surfaces (Au-masking of metallic surfaces) is a novel and efficient method for study of denture surfaces. Generally, this approach is of interest for corrosion studies of different metals and alloys, particularly where changes in surface structure have a significant importance.

  4. Microstructure and mechanical properties of sintered Ti Binary alloys for dental applications

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz Atay, H.; Haro Rodriguez, M.; Amigo Mata, A.; Vicente Escuder, V.; Amigo Borras, V.

    2016-07-01

    Biomaterials have shown rapid growth in the field of elderly population demands with the prolongation of human life. One of those biomaterials, titanium, has excellent properties and biocompatibility though it may cause weakening in the structures due to its higher stiffness. In this study, powder metallurgy process was used to produce Ti-Cr, Ti-Mo and Ti-Cu metal alloys to overcome this problem. Metal powders were mixed by mechanical alloying. After pressing and sintering, alloys structures were investigated. Characterizations were carried out by size analyzer, SEM-EDX, optical microscope and three points bending test. (Author)

  5. Electrochemical assessment of some titanium and stainless steel impact dental alloys

    International Nuclear Information System (INIS)

    Echavarria, A.; Arroyave, C.

    2003-01-01

    Commercially pure titanium alloy, Ti-6Al-4V alloy and stainless steel screw implants were evaluated in both Ringer and synthetic saliva physiological solutions at body temperature by EIS (Electrochemical Impedance Spectroscopy) with immersion times of 30 d. Results were simulated as a sandwich system composed by four capacitors-resistances connected in series with the solution resistance. A model explaining the results in terms of the porosity and thickness of four different layers, was proposed. (Author) 22 refs

  6. Effects of carbon concentration on microstructure and mechanical properties of as-cast nickel-free Co–28Cr–9W-based dental alloys

    International Nuclear Information System (INIS)

    Yamanaka, Kenta; Mori, Manami; Chiba, Akihiko

    2014-01-01

    We determined the effects of carbon concentration on the microstructures and tensile properties of the Ni-free Co–29Cr–9W–1Si–C (mass%) cast alloys used in dental applications. Alloy specimens prepared with carbon concentrations in the range 0.01–0.27 mass% were conventionally cast. Scanning electron microscopy (SEM) and electron probe microanalysis (EPMA) revealed that precipitates had formed in all the alloy specimens. The σ phase, a chromium-rich intermetallic compound, had formed in the region between the dendrite arms of the low-carbon-content (e.g., 0.01C) alloys. Adding carbon to the alloys increased the amount of interdendritic precipitates that formed and changed the precipitation behavior; the precipitated phase changed from the σ phase to the M 23 C 6 carbide with increasing carbon concentration. Adding a small amount of carbon (i.e., 0.04 mass%) to the alloys dramatically enhanced the 0.2% proof stress, which subsequently gradually increased with increasing content of carbon in the alloys. Elongation-to-failure, on the other hand, increased with increasing carbon content and showed a maximum at carbon concentrations of ∼ 0.1 mass%. The M 23 C 6 carbide formed at the interdendritic region may govern the tensile properties of the as-cast Co–Cr–W alloys similar to how it governed those of the hot-rolled alloys prepared in our previous study. - Highlights: • Microstructure and tensile properties of C-doped Co–Cr–W cast alloys was studied. • Adding carbon stabilized the γ matrix and changed the precipitation behavior. • Formation of carbide precipitates strengthened C-doped Co–Cr–Mo alloys. • A maximum tensile elongation was obtained at carbon concentrations of ∼0.1 mass%

  7. Development and properties of Ti–In binary alloys as dental biomaterials

    International Nuclear Information System (INIS)

    Wang, Q.Y.; Wang, Y.B.; Lin, J.P.; Zheng, Y.F.

    2013-01-01

    The objective of this study is to investigate the effect of alloying element indium on the microstructure, mechanical properties, corrosion behavior and in vitro cytotoxicity of Ti–In binary alloys, with the addition of 1, 5, 10 and 15 at.% indium. The phase constitution was studied by optical microscopic observation and X-ray diffraction measurements. The mechanical properties were characterized by tension and microhardness tests. Potentiodynamic polarization measurements were employed to investigate the corrosion behavior in artificial saliva solutions with and without fluoride. In vitro cytotoxicity was conducted by using L929 and NIH 3T3 mouse fibroblast cell lines, with commercially pure Ti (CP–Ti, ASTM grade 2) as negative control. All of the binary Ti–In alloys investigated in this work were found to have higher strength and microhardness than CP–Ti. Electrochemical results showed that Ti–In alloys exhibited the same order of magnitude of passivation current densities with CP–Ti in artificial saliva solutions. With the presence of NaF, Ti–10In and Ti–15In showed transpassive behavior and lower current densities at high potentials. All experimental Ti–In alloys showed good cytocompatibility, at the same level as CP–Ti. The addition of indium to titanium was effective on increasing the strength and microhardness, without impairing its good corrosion resistance and cytocompatibility. - Highlights: ► The addition of In into Ti can increase the mechanical property. ► Ti-In alloys exhibited similar passivation behavior with CP-Ti. ► Ti-In alloys had good cytocompatibility comparable with CP-Ti. ► Ti-10In and Ti-15In showed transpassive baheviour with the addition of NaF

  8. Corrosion in artificial saliva of a Ni-Cr-based dental alloy joined by TIG welding and conventional brazing.

    Science.gov (United States)

    Matos, Irma C; Bastos, Ivan N; Diniz, Marília G; de Miranda, Mauro S

    2015-08-01

    Fixed prosthesis and partial dental prosthesis frameworks are usually made from welded Ni-Cr-based alloys. These structures can corrode in saliva and have to be investigated to establish their safety. The purpose of this study was to evaluate the corrosion behavior of joints joined by tungsten inert gas (TIG) welding and conventional brazing in specimens made of commercial Ni-Cr alloy in Fusayama artificial saliva at 37°C (pH 2.5 and 5.5). Eighteen Ni-Cr base metal specimens were cast and welded by brazing or tungsten inert gas methods. The specimens were divided into 3 groups (base metal, 2 welded specimens), and the composition and microstructure were qualitatively evaluated. The results of potential corrosion and corrosion current density were analyzed with a 1-way analysis of variance and the Tukey test for pairwise comparisons (α=.05). Base metal and tungsten inert gas welded material showed equivalent results in electrochemical corrosion tests, while the air-torched specimens exhibited low corrosion resistance. The performance was worst at pH 2.5. These results suggest that tungsten inert gas is a suitable welding process for use in dentistry, because the final microstructure does not reduce the corrosion resistance in artificial saliva at 37°C, even in a corrosion-testing medium that facilitates galvanic corrosion processes. Moreover, the corrosion current density of brazed Ni-Cr alloy joints was significantly higher (P<.001) than the base metal and tungsten inert gas welded joints. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. [Differential study of the bonding characterization of dental porcelain to Ni-Cr alloys].

    Science.gov (United States)

    Wei, Fang; Zhan, De-song; Wang, Yan-yan

    2008-10-01

    To study the bonding capability when Ni-Cr porcelain alloy was added with Ti, compound rare earth metals and removed the element of Be. Ni-Cr-Ti porcelain alloys manufactured by Institute of Metal Research of Chinese Academy of Sciences were tested. The test alloys were divided into three groups according to whether containing Be and compound rare earth metals or not. And HI BOND Ni-Cr base-metal alloy was chosen as control. The metal-ceramic specimens were prepared for shear test, scanning electron microscope (SEM) and energy spectrum analysis. The shear bond strength of the four groups were analyzed. No significant difference were observed among them (P > 0.05). No crackle was found and they were contacted tightly between the porcelain and metal. The composition and contents of the four groups' interfaces were closed. The shear bond strength of the self-made Ni-Cr-Ti porcelain alloys all can satisfy the clinical requirements. Experimental groups containing Ti, compound rare earth metals and removing the element of Be can be used as better recommendation for clinical practice.

  10. Castability of Ti-6Al-7Nb alloy for dental casting

    OpenAIRE

    Wang, Tie Jun; 小林, 郁夫; 土居, 壽; 米山, 隆之

    1999-01-01

    Castability of Ti-6Al-7Nb alloy, CP Ti, and Co-Cr alloy was examined for mesh type and plate type specimens. The casting was carried out with a pressure type casting machine and commercial molding material. The castability of the mesh type specimen was evaluated in terms of the number of cast segments (castability index), and that of the plate type was evaluated by the area of the speci­men (casting rate). X-ray images processed by a digital imaging technique were used to identify the casting...

  11. [A surface reacted layer study of titanium-zirconium alloy after dental casting].

    Science.gov (United States)

    Zhang, Y; Guo, T; Li, Z; Li, C

    2000-10-01

    To investigate the influence of the mold temperature on the surface reacted layer of Ti-Zr alloy castings. Ti-Zr alloy was casted into a mold which was made of a zircon (ZrO2.SiO2) for inner coating and a phosphate-bonded material for outer investing with a casting machine (China) designed as vacuum, pressure and centrifuge. At three mold temperatures (room temperature, 300 degrees C, 600 degrees C) the Ti-Zr alloy was casted separately. The surface roughness of the castings was calculated by instrument of smooth finish (China). From the surface to the inner part the Knoop hardness and thickness in reacted layer of Ti-Zr alloy casting was measured. The structure of the surface reacted layer was analysed by SEM. Elemental analyses of the interfacial zone of the casting was made by element line scanning observation. The surface roughness of the castings was increased significantly with the mold temperature increasing. At a higher mold temperature the Knoop hardness of the reactive layer was increased. At the three mold temperature the outmost surface was very hard, and microhardness data decreased rapidly where they reached constant values. The thickness was about 85 microns for castings at room temperature and 300 degrees C, 105 microns for castings at 600 degrees C. From the SEM micrograph of the Ti-Zr alloy casting, the surface reacted layer could be divided into three different layers. The first layer was called non-structure layer, which thickness was about 10 microns for room temperature group, 20 microns for 300 degrees C and 25 microns for 600 degrees C. The second layer was characterized by coarse-grained acicular crystal, which thickness was about 50 microns for three mold temperatures. The third layer was Ti-Zr alloy. The element line scanning showed non-structure layer with higher level of element of O, Al, Si and Zr, The higher the mold temperature during casting, the deeper the Si permeating and in the second layer the element Si could also be found

  12. Effect of finishing process on the surface quality of Co-Cr-Mo dental alloys

    Directory of Open Access Journals (Sweden)

    Dorota Klimecka -Tatar

    2016-09-01

    Full Text Available Preparatory procedures for the material have a significant influence on the surface stereometry of the material. This study investigated the effect of the electropolishing process on the surface quality of metallic prosthetic constructions based on Co-Cr-Mo alloys. It has been found that the process of electropolishing prevents to excessive development of the surface of a material and consequently improves surface quality.

  13. Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

    Science.gov (United States)

    Akça, Kıvanç; Eser, Atılım; Çavuşoğlu, Yeliz; Sağırkaya, Elçin; Çehreli, Murat Cavit

    2015-05-01

    The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a localized part of the global model with a refined mesh. The peri-implant tissues around conventionally loaded (model 1) and early loaded (model 2) implants were implemented and were used to explore principal stresses, displacement values, and equivalent strains in the peri-implant region of titanium and titanium-zirconium implants under static load of 300 N with or without 30° inclination applied on top of the abutment surface. Under axial loading, principal stresses in both models were comparable for both implants and models. Under oblique loading, principal stresses around titanium-zirconium implants were slightly higher in both models. Comparable stress magnitudes were observed in both models. The displacement values and equivalent strain amplitudes around both implants and models were similar. Peri-implant bone around titanium and titanium-zirconium implants experiences similar stress magnitudes coupled with intraosseous implant displacement values under conventional loading and early loading simulations. Titanium-zirconium implants have biomechanical outcome comparable to conventional titanium implants under conventional loading and early loading.

  14. Parallel sorting algorithms

    CERN Document Server

    Akl, Selim G

    1985-01-01

    Parallel Sorting Algorithms explains how to use parallel algorithms to sort a sequence of items on a variety of parallel computers. The book reviews the sorting problem, the parallel models of computation, parallel algorithms, and the lower bounds on the parallel sorting problems. The text also presents twenty different algorithms, such as linear arrays, mesh-connected computers, cube-connected computers. Another example where algorithm can be applied is on the shared-memory SIMD (single instruction stream multiple data stream) computers in which the whole sequence to be sorted can fit in the

  15. Enhancement of wear and corrosion resistance of low modulus β-type Zr-20Nb-xTi (x=0, 3) dental alloys through thermal oxidation treatment.

    Science.gov (United States)

    Zhang, Jianfeng; Gan, Xiaxia; Tang, Hongqun; Zhan, Yongzhong

    2017-07-01

    In order to obtain material with low elastic modulus, good abrasion resistance and high corrosion stability as screw for dental implant, the biomedical Zr-20Nb and Zr-20Nb-3Ti alloy with low elastic modulus were thermal oxidized respectively at 700°C for 1h and 600°C for 1.25h to obtain the compact oxidized layer to improve its wear resistance and corrosion resistance. The results show that smooth compact oxidized layer (composed of monoclinic ZrO 2 , tetragonal ZrO 2 and 6ZrO 2 -Nb 2 O 5 ) with 22.6μm-43.5μm thickness and 1252-1306HV hardness can be in-situ formed on the surface of the Zr-20Nb-xTi (x=0, 3). The adhesion of oxidized layers to the substrates is determined to be 58.35-66.25N. The oxidized Zr-20Nb-xTi alloys reveal great improvement of the pitting corrosion resistance in comparison with the un-oxidized alloys. In addition, the oxidized Zr-20Nb-3Ti exhibits sharply reduction of the corrosion rates and the oxidized Zr-20Nb shows higher corrosion rates than un-oxidized alloys, which is relevant with the content of the t-ZrO 2 . Wear test in artificial saliva demonstrates that the wear losses of the oxidized Zr-20Nb-xTi (x=0, 3) are superior to pure Ti. All of the un-oxidized Zr-20Nb-xTi (x=0, 3) alloys suffer from serious adhesive wear due to its high plasticity. Because of the protection from compact oxide layer with high adhesion and high hardness, the coefficients of friction and wear losses of the oxidized Zr-20Nb-xTi (x=0, 3) alloys decrease 50% and 95%, respectively. The defects on the oxidized Zr-20Nb have a negative effect on the friction and wear properties. In addition, after the thermal oxidation, compression test show that elastic modulus and strength of Zr-20Nb-xTi (x=0, 3) increase slightly with plastic deformation after 40% of transformation. Furthermore, stripping of the oxidized layer from the alloy matrix did not occur during the whole experiments. As the surface oxidized Zr-20Nb-3Ti alloy has a combination of excellent performance

  16. [The study of the colorimetric characteristics of the cobalt-chrome alloys abutments covered by four different all-ceramic crowns by using dental spectrophotometer].

    Science.gov (United States)

    Chen, Yifan; Liu, Hongchun; Meng, Yukun; Chao, Yonglie; Liu, Changhong

    2015-06-01

    This study aims to evaluate the optical data of the different sites of the cobalt-chrome (Co-Cr) alloy abutments covered by four different all-ceramic crowns and the color difference between the crowns and target tab using a digital dental spectrophotometer. Ten Co-Cr alloy abutments were made and tried in four different groups of all-ceramic crowns, namely, Procera aluminia, Procera zirconia, Lava zirconia (Lava-Zir), and IPS E.max glass-ceramic lithium disilicate-reinforced monolithic. The color data of the cervical, body, and incisal sites of the samples were recorded and analyzed by dental spectrophotometer. The CIE L*, a*, b* values were again measured after veneering. The color difference between the abutments covered by all-ceramic crowns and A2 dentine shade tab was evaluated. The L* and b* values of the abutments can be increased by all of the four groups of all-ceramic copings, but a* values were decreased in most groups. A statistical difference was observed among four groups. After being veneered, the L* values of all the copings declined slightly, and the values of a*, b* increased significantly. When compared with A2 dentine shade tab, the ΔE of the crowns was below 4. Four ceramic copings were demonstrated to promote the lightness and hue of the alloy abutments effecttively. Though the colorimetric baseline of these copings was uneven, veneer porcelain can efficiently decrease the color difference between the samples and thee target.

  17. Sorting a distribution theory

    CERN Document Server

    Mahmoud, Hosam M

    2011-01-01

    A cutting-edge look at the emerging distributional theory of sorting Research on distributions associated with sorting algorithms has grown dramatically over the last few decades, spawning many exact and limiting distributions of complexity measures for many sorting algorithms. Yet much of this information has been scattered in disparate and highly specialized sources throughout the literature. In Sorting: A Distribution Theory, leading authority Hosam Mahmoud compiles, consolidates, and clarifies the large volume of available research, providing a much-needed, comprehensive treatment of the

  18. Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions.

    Science.gov (United States)

    Bosshardt, Dieter D; Chappuis, Vivianne; Buser, Daniel

    2017-02-01

    Bone healing around dental implants follows the pattern and sequence of intramembraneous osteogenesis with formation of woven bone first of all followed later by formation of parallel-fibered and lamellar bone. Bone apposition onto the implant surface starts earlier in trabecular bone than in compact bone. While the first new bone may be found on the implant surface around 1 week after installation, bone remodeling starts at between 6 and 12 weeks and continues throughout life. Bone remodeling also involves the bone-implant interface, thus transiently exposing portions of the implant surface. Surface modifications creating micro-rough implant surfaces accelerate the osseointegration process of titanium implants, as demonstrated in numerous animal experiments. Sandblasting followed by acid-etching may currently be regarded as the gold standard technique to create micro-rough surfaces. Chemical surface modifications, resulting in higher hydrophilicity, further increase the speed of osseointegration of titanium and titanium-zirconium implants in both animals and humans. Surface modifications of zirconia and alumina-toughened zirconia implants also have an influence on the speed of osseointegration, and some implant types reach high bone-to-implant contact values in animals. Although often discussed independently of each other, surface characteristics, such as topography and chemistry, are virtually inseparable. Contemporary, well-documented implant systems with micro-rough implant surfaces, placed by properly trained and experienced clinicians, demonstrate high long-term survival rates. Nevertheless, implant failures do occur. A low percentage of implants are diagnosed with peri-implantitis after 10 years in function. In addition, a low number of implants seem to be lost for primarily reasons other than biofilm-induced infection. Patient factors, such as medications interfering with the immune system and bone cells, may be an element contributing to continuous bone

  19. New Ti-Alloys and Surface Modifications to Improve the Mechanical Properties and the Biological Response to Orthopedic and Dental Implants: A Review

    Science.gov (United States)

    Kirmanidou, Yvoni; Sidira, Margarita; Drosou, Maria-Eleni; Bennani, Vincent; Bakopoulou, Athina; Tsouknidas, Alexander; Michailidis, Nikolaos; Michalakis, Konstantinos

    2016-01-01

    Titanium implants are widely used in the orthopedic and dentistry fields for many decades, for joint arthroplasties, spinal and maxillofacial reconstructions, and dental prostheses. However, despite the quite satisfactory survival rates failures still exist. New Ti-alloys and surface treatments have been developed, in an attempt to overcome those failures. This review provides information about new Ti-alloys that provide better mechanical properties to the implants, such as superelasticity, mechanical strength, and corrosion resistance. Furthermore, in vitro and in vivo studies, which investigate the biocompatibility and cytotoxicity of these new biomaterials, are introduced. In addition, data regarding the bioactivity of new surface treatments and surface topographies on Ti-implants is provided. The aim of this paper is to discuss the current trends, advantages, and disadvantages of new titanium-based biomaterials, fabricated to enhance the quality of life of many patients around the world. PMID:26885506

  20. Fatigue Life of Titanium Alloys Fabricated by Additive Layer Manufacturing Techniques for Dental Implants

    Science.gov (United States)

    Chan, Kwai S.; Koike, Marie; Mason, Robert L.; Okabe, Toru

    2013-02-01

    Additive layer deposition techniques such as electron beam melting (EBM) and laser beam melting (LBM) have been utilized to fabricate rectangular plates of Ti-6Al-4V with extra low interstitial (ELI) contents. The layer-by-layer deposition techniques resulted in plates that have different surface finishes which can impact significantly on the fatigue life by providing potential sites for fatigue cracks to initiate. The fatigue life of Ti-6Al-4V ELI alloys fabricated by EBM and LBM deposition techniques was investigated by three-point testing of rectangular beams of as-fabricated and electro-discharge machined surfaces under stress-controlled conditions at 10 Hz until complete fracture. Fatigue life tests were also performed on rolled plates of Ti-6Al-4V ELI, regular Ti-6Al-4V, and CP Ti as controls. Fatigue surfaces were characterized by scanning electron microscopy to identify the crack initiation site in the various types of specimen surfaces. The fatigue life data were analyzed statistically using both analysis of variance techniques and the Kaplan-Meier survival analysis method with the Gehan-Breslow test. The results indicate that the LBM Ti-6Al-4V ELI material exhibits a longer fatigue life than the EBM counterpart and CP Ti, but a shorter fatigue life compared to rolled Ti-6Al-4V ELI. The difference in the fatigue life behavior may be largely attributed to the presence of rough surface features that act as fatigue crack initiation sites in the EBM material.

  1. Corrosion behaviours of the dental magnetic keeper complexes made by different alloys and methods.

    Science.gov (United States)

    Wu, Min-Ke; Song, Ning; Liu, Fei; Kou, Liang; Lu, Xiao-Wen; Wang, Min; Wang, Hang; Shen, Jie-Fei

    2016-09-29

    The keeper and cast dowel-coping, as a primary component for a magnetic attachment, is easily subjected to corrosion in a wet environment, such as the oral cavity, which contains electrolyte-rich saliva, complex microflora and chewing behaviour and so on. The objective of this in vitro study was to examine the corrosion resistance of a dowel and coping-keeper complex fabricated by finish keeper and three alloys (cobalt-chromium, CoCr; silver-palladium-gold, PdAu; gold-platinum, AuPt) using a laser-welding process and a casting technique. The surface morphology characteristics and microstructures of the samples were examined by means of metallographic microscope and scanning electron microscope (SEM). Energy-dispersive spectroscopy (EDS) with SEM provided elements analysis information for the test samples after 10% oxalic acid solution etching test. Tafel polarization curve recordings demonstrated parameter values indicating corrosion of the samples when subjected to electrochemical testing. This study has suggested that massive oxides are attached to the surface of the CoCr-keeper complex but not to the AuPt-keeper complex. Only the keeper area of cast CoCr-keeper complex displayed obvious intergranular corrosion and changes in the Fe and Co elements. Both cast and laser-welded AuPt-keeper complexes had the highest free corrosion potential, followed by the PdAu-keeper complex. We concluded that although the corrosion resistance of the CoCr-keeper complex was worst, the keeper surface passive film was actually preserved to its maximum extent. The laser-welded CoCr- and PdAu-keeper complexes possessed superior corrosion resistance as compared with their cast specimens, but no significant difference was found between the cast and laser-welded AuPt-keeper complexes. The Fe-poor and Cr-rich band, appearing on the edge of the keeper when casting, has been proven to be a corrosion-prone area.

  2. Sorting out Downside Beta

    NARCIS (Netherlands)

    G.T. Post (Thierry); P. van Vliet (Pim); S.D. Lansdorp (Simon)

    2009-01-01

    textabstractDownside risk, when properly defined and estimated, helps to explain the cross-section of US stock returns. Sorting stocks by a proper estimate of downside market beta leads to a substantially larger cross-sectional spread in average returns than sorting on regular market beta. This

  3. Three Sorts of Naturalism

    DEFF Research Database (Denmark)

    Fink, Hans

    2006-01-01

    In "Two sorts of Naturalism" John McDowell is sketching his own sort of naturalism in ethics as an alternative to "bald naturalism". In this paper I distinguish materialist, idealist and absolute conceptions of nature and of naturalism in order to provide a framework for a clearer understanding...

  4. Perbandingan Kecepatan Gabungan Algoritma Quick Sort dan Merge Sort dengan Insertion Sort, Bubble Sort dan Selection Sort

    OpenAIRE

    Al Rivan, Muhammad Ezar

    2017-01-01

    Ordering is one of the process done before doing data processing. The sorting algorithm has its own strengths and weaknesses. By taking strengths of each algorithm then combined can be a better algorithm. Quick Sort and Merge Sort are algorithms that divide the data into parts and each part divide again into sub-section until one element. Usually one element join with others and then sorted by. In this experiment data divide into parts that have size not more than threshold. This part then so...

  5. Microstructure, hardness, corrosion resistance and porcelain shear bond strength comparison between cast and hot pressed CoCrMo alloy for metal-ceramic dental restorations.

    Science.gov (United States)

    Henriques, B; Soares, D; Silva, F S

    2012-08-01

    The purpose of this study was to compare the microstructure, hardness, corrosion resistance and metal-porcelain bond strength of a CoCrMo dental alloy obtained by two routes, cast and hot pressing. CoCrMo alloy substrates were obtained by casting and hot pressing. Substrates' microstructure was examined by the means of Optical Microscopy (OM) and by Scanning Electron Microscope (SEM) and Energy Dispersive X-ray Spectroscopy (EDS). Hardness tests were performed in a microhardness indenter. The electrochemical behavior of substrates was investigated through potentiodynamic tests in a saline solution (8g NaCl/L). Substrates were bonded to dental porcelain and metal-porcelain bond strength was assessed by the means of a shear test performed in a universal test machine (crosshead speed: 0.5 mm/min) until fracture. Fractured surfaces as well as undestroyed interface specimens were examined with Stereomicroscopy and SEM-EDS. Data was analyzed with Shapiro-Wilk test to test the assumption of normality. The t-test (pmicrostructures whereas hot pressed specimens exhibited a typical globular microstructure with a second phase spread through the matrix. The hardness registered for hot pressed substrates was greater than that of cast specimens, 438±24HV/1 and 324±8HV/1, respectively. Hot pressed substrates showed better corrosion properties than cast ones, i.e. higher OCP; higher corrosion potential (E(corr)) and lower current densities (i(corr)). No significant difference was found (p<0.05) in metal-ceramic bond strength between cast (116.5±6.9 MPa) and hot pressed (114.2±11.9 MPa) substrates. The failure type analysis revealed an adhesive failure for all specimens. Hot pressed products arise as an alternative to cast products in dental prosthetics, as they impart enhanced mechanical and electrochemical properties to prostheses without compromising the metal-ceramic bond strength. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Sorting Out Seasonal Allergies

    Science.gov (United States)

    ... Close ‹ Back to Healthy Living Sorting Out Seasonal Allergies Sneezing, runny nose, nasal congestion. Symptoms of the ... How do I know if I have seasonal allergies? According to Dr. Georgeson, the best way to ...

  7. Wage Sorting Trends

    DEFF Research Database (Denmark)

    Bagger, Jesper; Vejlin, Rune Majlund; Sørensen, Kenneth Lykke

    Using a population-wide Danish Matched Employer-Employee panel from 1980-2006, we document a strong trend towards more positive assortative wage sorting. The correlation between worker and firm fixed effects estimated from a log wage regression increases from -0.07 in 1981 to .14 in 2001. The non......Using a population-wide Danish Matched Employer-Employee panel from 1980-2006, we document a strong trend towards more positive assortative wage sorting. The correlation between worker and firm fixed effects estimated from a log wage regression increases from -0.07 in 1981 to .14 in 2001....... The nonstationary wage sorting pattern is not due to compositional changes in the labor market, primarily occurs among high wage workers, and comprises 41 percent of the increase in the standard deviation of log real wages between 1980 and 2006. We show that the wage sorting trend is associated with worker...

  8. Glossary of Dental Terms

    Science.gov (United States)

    ... more... Coffee and Doughnuts: A Disastrous Combo for Teeth? The sugars in doughnuts have been identified as ... More print this article enlarge text Glossary of Dental Terms Oral Health Defined Amalgam silver/mercury alloy ...

  9. What is a Sorting Function?

    DEFF Research Database (Denmark)

    Henglein, Fritz

    2009-01-01

    What is a sorting function—not a sorting function for a given ordering relation, but a sorting function with nothing given? Formulating four basic properties of sorting algorithms as defining requirements, we arrive at intrinsic notions of sorting and stable sorting: A function is a sorting...... are derivable without compromising data abstraction. Finally we point out that stable sorting functions as default representations of ordering relations have the advantage of permitting linear-time sorting algorithms; inequality tests forfeit this possibility....... function if and only it is an intrinsically parametric permutation function. It is a stable sorting function if and only if it is an intrinsically stable permutation function. We show that ordering relations can be represented isomorphically as inequality tests, comparators and stable sorting functions...

  10. LazySorted: A Lazily, Partially Sorted Python List

    Directory of Open Access Journals (Sweden)

    Naftali Harris

    2015-06-01

    Full Text Available LazySorted is a Python C extension implementing a partially and lazily sorted list data structure. It solves a common problem faced by programmers, in which they need just part of a sorted list, like its middle element (the median, but sort the entire list to get it. LazySorted presents them with the abstraction that they are working with a fully sorted list, while actually only sorting the list partially with quicksort partitions to return the requested sub-elements. This enables programmers to use naive "sort first" algorithms but nonetheless attain linear run-times when possible. LazySorted may serve as a drop-in replacement for the built-in sorted function in most cases, and can sometimes achieve run-times more than 7 times faster.

  11. Ready, steady, SORT!

    CERN Document Server

    Laëtitia Pedroso

    2010-01-01

    The selective or ecological sorting of waste is already second nature to many of us and concerns us all. As the GS Department's new awareness-raising campaign reminds us, everything we do to sort waste contributes to preserving the environment.    Placemats printed on recycled paper using vegetable-based ink will soon be distributed in Restaurant No.1.   Environmental protection is never far from the headlines, and CERN has a responsibility to ensure that the 3000 tonnes and more of waste it produces every year are correctly and selectively sorted. Materials can be given a second life through recycling and re-use, thereby avoiding pollution from landfill sites and incineration plants and saving on processing costs. The GS Department is launching a new poster campaign designed to raise awareness of the importance of waste sorting and recycling. "After conducting a survey to find out whether members of the personnel were prepared to make an effort to sort a...

  12. Influence of thermo-mechanical cycling on porcelain bonding to cobalt-chromium and titanium dental alloys fabricated by casting, milling, and selective laser melting.

    Science.gov (United States)

    Antanasova, Maja; Kocjan, Andraž; Kovač, Janez; Žužek, Borut; Jevnikar, Peter

    2018-04-01

    The aim has been to determine the effect of thermo-mechanical cycling on shear-bond-strength (SBS) of dental porcelain to Co-Cr and Ti-based alloys fabricated by casting, computer-numerical-controlled milling, and selective-laser-melting (SLM). Seven groups (n=22/group) of metal cylinders were fabricated by casting (Co-Cr and commercially pure-cpTi), milling (Co-Cr, cpTi, Ti-6Al-4V) or by SLM (Co-Cr and Ti-6Al-4V) and abraded with airborne-particles. The average surface roughness (R a ) was determined for each group. Dental porcelain was applied and each metal-ceramic combination was divided into two subgroups - stored in deionized water (24-h, 37°C), or subjected to both thermal (6000-cycles, between 5 and 60°C) and mechanical cycling (10 5 -cycles, 60N-load). SBS test-values and failure modes were recorded. Metal-ceramic interfaces were analyzed with a focused-ion-beam/scanning-electron-microscope (FIB/SEM) and energy-dispersive-spectroscopy (EDS). The elastic properties of the respective metal and ceramic materials were evaluated by instrumented-indentation-testing. The oxide thickness on intact Ti-based substrates was measured with Auger-electron-spectroscopy (AES). Data were analyzed using ANOVA, Tukey's HSD and t-tests (α=0.05). The SBS-means differed according to the metal-ceramic combination (p<0.0005) and to the fatigue conditions (p<0.0005). The failure modes and interface analyses suggest better porcelain adherence to Co-Cr than to Ti-based alloys. Values of R a were dependent on the metal substrate (p<0.0005). Ti-based substrates were not covered with thick oxide layers following digital fabrication. Ti-based alloys are more susceptible than Co-Cr to reduction of porcelain bond strength following thermo-mechanical cycling. The porcelain bond strength to Ti-based alloys is affected by the applied metal processing technology. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  13. Selected Properties And Tribological Wear Alloys Co-Cr-Mo And Co-Cr-Mo-W Used In Dental Prosthetics

    Directory of Open Access Journals (Sweden)

    Augustyn-Pieniążek J.

    2015-09-01

    Full Text Available The presented work provides the results of the abrasive wear resistance tests performed on Co-Cr-Mo and Co-Cr-Mo-W alloys with the use of the Miller’s apparatus. The analyzed alloys underwent microstructure observations as well as hardness measurements, and the abraded surfaces of the examined materials were observed by means of electron scanning microscopy. The performed examinations made it possible to state that the Co-Cr alloys characterized in a high hardness, whereas the changes in the mass decrement were minimal, which proved a high abrasive wear resistance.

  14. Osseointegration of KrF laser hydroxylapatite films on Ti6A14V alloy by mini-pigs: loaded osseointegration of dental implants

    Science.gov (United States)

    Dostalova, Tatjana; Jelinek, Miroslav; Himmlova, Lucia; Grivas, Christos

    1999-05-01

    Aim of study was to evaluate osseointegration of the KrF laser hydroxyapatite coated titanium alloy Ti6Al4V dental implants. For deposition KrF excimer laser in stainless- steel deposition chamber was used. Thickness of HA films were round 1 μm . Mini-pigs were used in this investigation. Implants were placed vertically into the lower jaw. After 14 weeks unloaded osseointegration the metal ceramic crowns were inserted. the experimental animals were sacrificed (1 year post insertion). The vertical position of implants was controlled with a radiograph. Microscopical sections were cut and ground. Sections were viewed using microscope with CCD camera. 1 year osseointegration in lower jaw confirmed by all implants presence of newly formed bone around the all implants. Laser-deposited coating the layer of fibrous connective tissue was seen only seldom. In the control group (titamium implant without cover) the fibrous connective tissue was seen between implant and newly formed bone.

  15. Magnet sorting algorithms

    International Nuclear Information System (INIS)

    Dinev, D.

    1996-01-01

    Several new algorithms for sorting of dipole and/or quadrupole magnets in synchrotrons and storage rings are described. The algorithms make use of a combinatorial approach to the problem and belong to the class of random search algorithms. They use an appropriate metrization of the state space. The phase-space distortion (smear) is used as a goal function. Computational experiments for the case of the JINR-Dubna superconducting heavy ion synchrotron NUCLOTRON have shown a significant reduction of the phase-space distortion after the magnet sorting. (orig.)

  16. Sorting and sustaining cooperation

    DEFF Research Database (Denmark)

    Vikander, Nick

    2013-01-01

    This paper looks at cooperation in teams where some people are selfish and others are conditional cooperators, and where lay-offs will occur at a fixed future date. I show that the best way to sustain cooperation prior to the lay-offs is often in a sorting equilibrium, where conditional cooperators...... can identify and then work with one another. Changes to parameters that would seem to make cooperation more attractive, such as an increase in the discount factor or the fraction of conditional cooperators, can reduce equilibrium cooperation if they decrease a selfish player's incentive to sort....

  17. Three Sorts of Naturalism

    OpenAIRE

    Fink, Hans

    2006-01-01

    In "Two sorts of Naturalism" John McDowell is sketching his own sort of naturalism in ethics as an alternative to "bald naturalism". In this paper I distinguish materialist, idealist and absolute conceptions of nature and of naturalism in order to provide a framework for a clearer understanding of what McDowell's own naturalism amounts to. I argue that nothing short of an absolute naturalism will do for a number of McDowell's own purposes, but that it is far from obvious that this is his posi...

  18. Machinability of an experimental Ti-Ag alloy in terms of tool life in a dental CAD/CAM system.

    Science.gov (United States)

    Inagaki, Ryoichi; Kikuchi, Masafumi; Takahashi, Masatoshi; Takada, Yukyo; Sasaki, Keiichi

    2015-01-01

    Titanium is difficult to machine because of its intrinsic properties. In a previous study, the machinability of titanium was improved by alloying with silver. This study aimed to evaluate the durability of tungsten carbide burs after the fabrication of frameworks using a Ti-20%Ag alloy and titanium with a computer-aided design and computer-aided manufacturing system. There was a significant difference in attrition area ratio between the two metals. Compared with titanium, the ratio of the area of attrition of machining burs was significantly lower for the experimental Ti-20%Ag alloy. The difference in the area of attrition for titanium and Ti-20%Ag became remarkable with increasing number of machining operations. The results show that the same burs can be used for a longer time with Ti-20%Ag than with pure titanium. Therefore, in terms of tool life, the machinability of the Ti-20%Ag alloy is superior to that of titanium.

  19. Microstructures and Mechanical Properties of Co-Cr Dental Alloys Fabricated by Three CAD/CAM-Based Processing Techniques

    Directory of Open Access Journals (Sweden)

    Hae Ri Kim

    2016-07-01

    Full Text Available The microstructures and mechanical properties of cobalt-chromium (Co-Cr alloys produced by three CAD/CAM-based processing techniques were investigated in comparison with those produced by the traditional casting technique. Four groups of disc- (microstructures or dumbbell- (mechanical properties specimens made of Co-Cr alloys were prepared using casting (CS, milling (ML, selective laser melting (SLM, and milling/post-sintering (ML/PS. For each technique, the corresponding commercial alloy material was used. The microstructures of the specimens were evaluated via X-ray diffractometry, optical and scanning electron microscopy with energy-dispersive X-ray spectroscopy, and electron backscattered diffraction pattern analysis. The mechanical properties were evaluated using a tensile test according to ISO 22674 (n = 6. The microstructure of the alloys was strongly influenced by the manufacturing processes. Overall, the SLM group showed superior mechanical properties, the ML/PS group being nearly comparable. The mechanical properties of the ML group were inferior to those of the CS group. The microstructures and mechanical properties of Co-Cr alloys were greatly dependent on the manufacturing technique as well as the chemical composition. The SLM and ML/PS techniques may be considered promising alternatives to the Co-Cr alloy casting process.

  20. Precipitation of β′ phase and hardening in dental-casting Ag–20Pd–12Au–14.5Cu alloys subjected to aging treatments

    International Nuclear Information System (INIS)

    Kim, Yonghwan; Niinomi, Mitsuo; Hieda, Junko; Nakai, Masaaki; Cho, Ken; Fukui, Hisao

    2014-01-01

    The age-hardening behavior of the dental-casting Ag–20Pd–12Au–14.5Cu alloy subjected to aging treatment at around 673 K is well known, and this hardening has been widely employed in various applications. To date, the age-hardening of this alloy has been explained to attribute to the precipitation of a β phase, which is a B2-type ordered CuPd phase or PdCu x Zn 1−x phase. In this study, results obtained from microstructural observations using a transmission electron microscopy and a scanning transmission electron microscopy revealed that a fine L1 0 -type ordered β′ phase precipitated in the matrix and a coarse-structure region (consisting of Ag- and Cu-rich regions) appeared after aging treatment at 673 K and contributed to increase in hardness. The microstructure of the coarse β phase, which existed before aging treatment, did not change by aging treatment. Thus, it is concluded that the fine β′ phase precipitated by aging treatment contributed more to increase in hardness than the coarse-structure region and coarse β phase. - Highlights: • Hardness of Ag–20Pd–12Au–14.5Cu alloy increased significantly by aging treatment. • A fine β′ phase and a coarse structure region appeared after aging treatment. • The microstructure of a coarse β phase did not change by aging treatment. • It is considered that the fine β′ phase contributed most to age-hardening

  1. Event shape sorting

    International Nuclear Information System (INIS)

    Kopecna, Renata; Tomasik, Boris

    2016-01-01

    We propose a novel method for sorting events of multiparticle production according to the azimuthal anisotropy of their momentum distribution. Although the method is quite general, we advocate its use in analysis of ultra-relativistic heavy-ion collisions where a large number of hadrons is produced. The advantage of our method is that it can automatically sort out samples of events with histograms that indicate similar distributions of hadrons. It takes into account the whole measured histograms with all orders of anisotropy instead of a specific observable (e.g., v 2 , v 3 , q 2 ). It can be used for more exclusive experimental studies of flow anisotropies which are then more easily compared to theoretical calculations. It may also be useful in the construction of mixed-events background for correlation studies as it allows to select events with similar momentum distribution. (orig.)

  2. A Sequence of Sorting Strategies.

    Science.gov (United States)

    Duncan, David R.; Litwiller, Bonnie H.

    1984-01-01

    Describes eight increasingly sophisticated and efficient sorting algorithms including linear insertion, binary insertion, shellsort, bubble exchange, shakersort, quick sort, straight selection, and tree selection. Provides challenges for the reader and the student to program these efficiently. (JM)

  3. Chip-based droplet sorting

    Energy Technology Data Exchange (ETDEWEB)

    Beer, Neil Reginald; Lee, Abraham; Hatch, Andrew

    2017-11-21

    A non-contact system for sorting monodisperse water-in-oil emulsion droplets in a microfluidic device based on the droplet's contents and their interaction with an applied electromagnetic field or by identification and sorting.

  4. Protein Sorting Prediction

    DEFF Research Database (Denmark)

    Nielsen, Henrik

    2017-01-01

    and drawbacks of each of these approaches is described through many examples of methods that predict secretion, integration into membranes, or subcellular locations in general. The aim of this chapter is to provide a user-level introduction to the field with a minimum of computational theory.......Many computational methods are available for predicting protein sorting in bacteria. When comparing them, it is important to know that they can be grouped into three fundamentally different approaches: signal-based, global-property-based and homology-based prediction. In this chapter, the strengths...

  5. Det sorte USA

    DEFF Research Database (Denmark)

    Brøndal, Jørn

    Bogen gennemgår det sorte USAs historie fra 1776 til 2016, idet grundtemaet er spændingsforholdet mellem USAs grundlæggelsesidealer og den racemæssige praksis, et spændingsforhold som Gunnar Myrdal kaldte "det amerikanske dilemma." Bogen, der er opbygget som politisk, social og racemæssig histori......, er opdelt i 13 kapitler og består af fire dele: Første del: Slaveriet; anden del: Jim Crow; tredje del. King-årene; fjerde del: Frem mod Obama....

  6. Gender Differences in Sorting

    DEFF Research Database (Denmark)

    Merlino, Luca Paolo; Parrotta, Pierpaolo; Pozzoli, Dario

    and causing the most productive female workers to seek better jobs in more female-friendly firms in which they can pursue small career advancements. Nonetheless, gender differences in promotion persist and are found to be similar in all firms when we focus on large career advancements. These results provide......In this paper, we investigate the sorting of workers in firms to understand gender gaps in labor market outcomes. Using Danish employer-employee matched data, we fiend strong evidence of glass ceilings in certain firms, especially after motherhood, preventing women from climbing the career ladder...

  7. Selective sorting of waste

    CERN Multimedia

    2007-01-01

    Not much effort needed, just willpower In order to keep the cost of disposing of waste materials as low as possible, CERN provides two types of recipient at the entrance to each building: a green plastic one for paper/cardboard and a metal one for general refuse. For some time now we have noticed, to our great regret, a growing negligence as far as selective sorting is concerned, with, for example, the green recipients being filled with a mixture of cardboard boxes full of polystyrene or protective wrappers, plastic bottles, empty yogurts pots, etc. …We have been able to ascertain, after careful checking, that this haphazard mixing of waste cannot be attributed to the cleaning staff but rather to members of the personnel who unscrupulously throw away their rubbish in a completely random manner. Non-sorted waste entails heavy costs for CERN. For information, once a non-compliant item is found in a green recipient, the entire contents are sent off for incineration rather than recycling… We are all concerned...

  8. Effects of surface treatments on bond strength of dental Ti-20Cr and Ti-10Zr alloys to porcelain

    International Nuclear Information System (INIS)

    Lin, Hsi-Chen; Wu, Shih-Ching; Ho, Wen-Fu; Huang, Ling-Hsiu; Hsu, Hsueh-Chuan

    2010-01-01

    The purpose of this study was to investigate the effect of surface treatments, including sandblasting and grinding, on the bond strength between a low-fusing porcelain and c.p. Ti, Ti-20Cr and Ti-10Zr alloys. The surface treatments were divided into 2 groups. Grinding surface treatment was applied to the first group, which served as the control, and sandblasting was applied to the second group. After treatment, low-fusing porcelain (Titankeramik) was fired onto the surface of the specimens. A universal testing machine was used to perform a 3-point bending test. The metal-ceramic interfaces were subjected to scanning electron microscopic analysis. Of the sandblasted samples, the debonding test showed that Ti-20Cr alloy had the strongest (31.50 MPa) titanium-ceramic bond (p < 005), followed by c.p. Ti (29.4 MPa) and Ti-10Zr (24.3 MPa). Of the grinded samples, Ti-20Cr alloy showed 27.3 MPa titanium-ceramic bond (p < 005), followed by c.p. Ti (14.3 MPa) and Ti-10Zr (failure). The SEM micrographs of the metal surface after debonding showed residual porcelain retained on all samples. On the whole, sandblasting surface treatment appears to have had a more beneficial effect on the Ti-ceramic bond strength than grinding surface treatment. Furthermore, surface treatment of Ti-20Cr with either grinding or sandblasting resulted in adequate bond strength, which exceeded the lower limit value in the ISO 9693 standard (25 MPa).

  9. Osseointegration of loaded dental implant with KrF laser hydroxylapatite films on Ti6Al4V alloy by minipigs

    Science.gov (United States)

    Dostalova, Tatjana; Himmlova, Lucia; Jelinek, Miroslav; Grivas, Christos

    2001-04-01

    This study was performed with the objective of evaluating osseointegration of titanium alloy Ti6Al4V dental implants coated with hydroxylapatite (HA) deposited by a KrF laser. For this a KrF excimer laser and stainless-steel deposition chamber were used. The thickness of the HA films was approximately 1 micrometers . IN this investigation experimental animals minipigs were used; the implants were placed vertically into the lower jaw. After 14 weeks of unloaded osseointegration, metal-ceramic crowns were inserted and, at the same time, fluorescent solution was injected into the experimental animals. Six months after insertion of crowns the animals were sacrificed. The vertical position of the implants was checked by a radiograph. Microscopic sections were cut and ground, and the sections were examined under polarized and fluorescent light using a microscope with a charge coupled device camera. The six month long osseointegration in the lower jaw has confirmed the presence of newly formed bone around all the implants. In the experimental group, which had a laser-deposited coating, the layer of fibrous connective tissue was seen only randomly. In the control group (titanium implant without a cover) the fibrous connective tissue between the implant and the newly formed bone was observed more frequently, but this difference was not significant.

  10. Simple sorting algorithm test based on CUDA

    OpenAIRE

    Meng, Hongyu; Guo, Fangjin

    2015-01-01

    With the development of computing technology, CUDA has become a very important tool. In computer programming, sorting algorithm is widely used. There are many simple sorting algorithms such as enumeration sort, bubble sort and merge sort. In this paper, we test some simple sorting algorithm based on CUDA and draw some useful conclusions.

  11. Dental Amalgam

    Science.gov (United States)

    ... Products and Medical Procedures Dental Devices Dental Amalgam Dental Amalgam Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Dental amalgam is a dental filling material which is ...

  12. Teleoperated robotic sorting system

    Science.gov (United States)

    Roos, Charles E.; Sommer, Edward J.; Parrish, Robert H.; Russell, James R.

    2000-01-01

    A method and apparatus are disclosed for classifying materials utilizing a computerized touch sensitive screen or other computerized pointing device for operator identification and electronic marking of spatial coordinates of materials to be extracted. An operator positioned at a computerized touch sensitive screen views electronic images of the mixture of materials to be sorted as they are conveyed past a sensor array which transmits sequences of images of the mixture either directly or through a computer to the touch sensitive display screen. The operator manually "touches" objects displayed on the screen to be extracted from the mixture thereby registering the spatial coordinates of the objects within the computer. The computer then tracks the registered objects as they are conveyed and directs automated devices including mechanical means such as air jets, robotic arms, or other mechanical diverters to extract the registered objects.

  13. Track data sort program

    International Nuclear Information System (INIS)

    Abramov, N.A.; Matveev, V.A.; Fedotov, O.P.

    1977-01-01

    The description is given of the MASKA program, based on the principle of sorting points array at surface due to their belonging to the topologically connected regions with boundaries of locked broken lines. The algorithm is realized on the ES-1010 computer for automatic image processing from the bubble chambers by scanning measuring projector. The methods are considered for constructing the above mentioned regions for all the images according to the base points measured on the semiautomatic measuring table. The MASKA program is written in the ASSEMBLER-2 language and equals 3.5K words of the main memory. The average processing time for 10000 points according to one mask is 1 sec

  14. Algorithm Sorts Groups Of Data

    Science.gov (United States)

    Evans, J. D.

    1987-01-01

    For efficient sorting, algorithm finds set containing minimum or maximum most significant data. Sets of data sorted as desired. Sorting process simplified by reduction of each multielement set of data to single representative number. First, each set of data expressed as polynomial with suitably chosen base, using elements of set as coefficients. Most significant element placed in term containing largest exponent. Base selected by examining range in value of data elements. Resulting series summed to yield single representative number. Numbers easily sorted, and each such number converted back to original set of data by successive division. Program written in BASIC.

  15. Perbandingan Bubble Sort dengan Insertion Sort pada Bahasa Pemrograman C dan Fortran

    OpenAIRE

    Reina, Reina; Gautama, Josef Bernadi

    2013-01-01

    Sorting is a basic algorithm studied by students of computer science major. Sorting algorithm is the basis of other algorithms such as searching algorithm, pattern matching algorithm. Bubble sort is a popular basic sorting algorithm due to its easiness to be implemented. Besides bubble sort, there is insertion sort. It is lesspopular than bubble sort because it has more difficult algorithm. This paper discusses about process time between insertion sort and bubble sort with two kinds of data. ...

  16. 21 CFR 872.3640 - Endosseous dental implant.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant. 872.3640 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3640 Endosseous dental implant. (a) Identification. An endosseous dental implant is a device made of a material such as titanium or titanium alloy, that...

  17. The effect of surface treatments on the microroughness of laser-sintered and vacuum-cast base metal alloys for dental prosthetic frameworks.

    Science.gov (United States)

    Castillo-Oyagüe, Raquel; Osorio, Raquel; Osorio, Estrella; Sánchez-Aguilera, Fátima; Toledano, Manuel

    2012-09-01

    This study aimed to evaluate the effect of four chemomechanical surface treatments on the surface average microroughness and profile of laser-sintered and vacuum-cast dental prosthetic structures. Square-shaped blocks (10 mm × 10 mm × 1.5 mm) were prepared as follows: (1) laser-sintered CoCr (L) (ST2724G); (2) cast Co-Cr (C) (Gemium-cn); and (3) cast Ni-Cr-Ti (T) (Tilite). Specimens of each alloy group were randomly divided into five subgroups (n = 10 each), depending on the conditioning method used: (1) no treatment (control); (2) sandblasting (125 μm Al₂O₃-particles); (3) silica coating (50 μm silica-modified Al₂O₃-particles); (4) oxidation; and (5) oxidation plus opacification. Subgroups 2 and 3 represent "inner" pretreatments proposed for ceramometal restorations to improve the metal surface area available for luting cements. Subgroups 4 and 5 are the "outer" pretreatments required for bonding the aesthetic veneering ceramics to the underlying metal frameworks. Average surface roughness (Ra/μm) was determined using a surface profilometer. Data were analyzed by two-way ANOVA and Student-Newman-Keuls tests (α = 0.05). Metal surface topography was SEM-analyzed. Despite the inner pretreatment applied, L samples resulted in the highest microroughness (P < 0.001), whereas sandblasting produced a surface-smoothing effect in cast specimens. After oxidation, a significant increase in surface roughness occurred in all groups compared with controls, L specimens being the roughest (P < 0.001). Opacification caused a flattening effect of all oxidized structures; all opacified groups resulting in similar microroughness. Laser sintering of Co-Cr enhances the roughness of metal structures, which may improve the frameworks' microretention of the cements, and of the opaquer before the copings are veneered with the aesthetic ceramics. Copyright © 2012 Wiley Periodicals, Inc.

  18. Flow sorting in aquatic ecology

    Directory of Open Access Journals (Sweden)

    Marcus Reckermann

    2000-06-01

    Full Text Available Flow sorting can be a very helpful tool in revealing phytoplankton and bacterial community structure and elaborating specific physiological parameters of isolated species. Droplet sorting has been the most common technique. Despite the high optical and hydro-dynamic stress for the cells to be sorted, many species grow in culture subsequent to sorting. To date, flow sorting has been applied to post-incubation separation in natural water samples to account for group-specific physiological parameters (radiotracer-uptake rates, to the production of clonal or non-clonal cultures from mixtures, to the isolaton of cell groups from natural assemblages for molecular analyses, and for taxonomic identification of sorted cells by microscopy. The application of cell sorting from natural water samples from the Wadden Sea, including different cryptophytes, cyanobacteria and diatoms, is shown, as well as the establishment of laboratory cultures from field samples. The optional use of a red laser to account for phycocyanine-rich cells is also discussed.

  19. Corrosion behaviour and surface analysis of a Co-Cr and two Ni-Cr dental alloys before and after simulated porcelain firing.

    Science.gov (United States)

    Qiu, Jing; Yu, Wei-Qiang; Zhang, Fu-Qiang; Smales, Roger J; Zhang, Yi-Lin; Lu, Chun-Hui

    2011-02-01

    This study evaluated the corrosion behaviour and surface properties of a commercial cobalt-chromium (Co-Cr) alloy and two nickel-chromium (Ni-Cr) alloys [beryllium (Be)-free and Be-containing] before and after a simulated porcelain-firing process. Before porcelain firing, the microstructure, surface composition and hardness, electrochemical corrosion properties, and metal-ion release of as-cast alloy specimens were examined. After firing, similar alloy specimens were examined for the same properties. In both as-cast and fired conditions, the Co-Cr alloy (Wirobond C) showed significantly more resistance to corrosion than the two Ni-Cr alloys. After firing, the corrosion rate of the Be-free Ni-Cr alloy (Stellite N9) increased significantly, which corresponded to a reduction in the levels of Cr, molybdenum (Mo), and Ni in the surface oxides and to a reduction in the thickness of the surface oxide film. The corrosion properties of the Co-Cr alloy and the Be-containing Ni-Cr alloy (ChangPing) were not significantly affected by the firing process. Porcelain firing also changed the microstructure and microhardness values of the alloys, and there were increases in the release of Co and Ni ions, especially for Ni from the Be-free Ni-Cr alloy. Thus, the corrosion rate of the Be-free Ni-Cr alloy increased significantly after porcelain firing, whereas the firing process had little effect on the corrosion susceptibility of the Co-Cr alloy and the Be-containing Ni-Cr alloy. © 2011 Eur J Oral Sci.

  20. ALGORITHM FOR SORTING GROUPED DATA

    Science.gov (United States)

    Evans, J. D.

    1994-01-01

    It is often desirable to sort data sets in ascending or descending order. This becomes more difficult for grouped data, i.e., multiple sets of data, where each set of data involves several measurements or related elements. The sort becomes increasingly cumbersome when more than a few elements exist for each data set. In order to achieve an efficient sorting process, an algorithm has been devised in which the maximum most significant element is found, and then compared to each element in succession. The program was written to handle the daily temperature readings of the Voyager spacecraft, particularly those related to the special tracking requirements of Voyager 2. By reducing each data set to a single representative number, the sorting process becomes very easy. The first step in the process is to reduce the data set of width 'n' to a data set of width '1'. This is done by representing each data set by a polynomial of length 'n' based on the differences of the maximum and minimum elements. These single numbers are then sorted and converted back to obtain the original data sets. Required input data are the name of the data file to read and sort, and the starting and ending record numbers. The package includes a sample data file, containing 500 sets of data with 5 elements in each set. This program will perform a sort of the 500 data sets in 3 - 5 seconds on an IBM PC-AT with a hard disk; on a similarly equipped IBM PC-XT the time is under 10 seconds. This program is written in BASIC (specifically the Microsoft QuickBasic compiler) for interactive execution and has been implemented on the IBM PC computer series operating under PC-DOS with a central memory requirement of approximately 40K of 8 bit bytes. A hard disk is desirable for speed considerations, but is not required. This program was developed in 1986.

  1. Layers in sorting practices: Sorting out patients with potential cancer

    DEFF Research Database (Denmark)

    Møller, Naja Holten; Bjørn, Pernille

    2011-01-01

    for a particular patient. Due to the limited resources within the Danish healthcare system, initiating cancer pathways for all patients with a remote suspicion of cancer would crash the system, as it would be impossible for healthcare professionals to commit to the prescribed schedules and times defined...... they show that sorting patients before initiating a standardized cancer pathway is not a simple process of deciding on a predefined category that will stipulate particular dates and times. Instead, these informal sorting mechanisms show that the process of sorting patients prior to diagnosis......In the last couple of years, widespread use of standardized cancer pathways has been seen across a range of countries, including Denmark, to improve prognosis of cancer patients. In Denmark, standardized cancer pathways take the form of guidelines prescribing well-defined sequences where steps...

  2. Sorting waves and associated eigenvalues

    Science.gov (United States)

    Carbonari, Costanza; Colombini, Marco; Solari, Luca

    2017-04-01

    The presence of mixed sediment always characterizes gravel bed rivers. Sorting processes take place during bed load transport of heterogeneous sediment mixtures. The two main elements necessary to the occurrence of sorting are the heterogeneous character of sediments and the presence of an active sediment transport. When these two key ingredients are simultaneously present, the segregation of bed material is consistently detected both in the field [7] and in laboratory [3] observations. In heterogeneous sediment transport, bed altimetric variations and sorting always coexist and both mechanisms are independently capable of driving the formation of morphological patterns. Indeed, consistent patterns of longitudinal and transverse sorting are identified almost ubiquitously. In some cases, such as bar formation [2] and channel bends [5], sorting acts as a stabilizing effect and therefore the dominant mechanism driving pattern formation is associated with bed altimetric variations. In other cases, such as longitudinal streaks, sorting enhances system instability and can therefore be considered the prevailing mechanism. Bedload sheets, first observed by Khunle and Southard [1], represent another classic example of a morphological pattern essentially triggered by sorting, as theoretical [4] and experimental [3] results suggested. These sorting waves cause strong spatial and temporal fluctuations of bedload transport rate typical observed in gravel bed rivers. The problem of bed load transport of a sediment mixture is formulated in the framework of a 1D linear stability analysis. The base state consists of a uniform flow in an infinitely wide channel with active bed load transport. The behaviour of the eigenvalues associated with fluid motion, bed evolution and sorting processes in the space of the significant flow and sediment parameters is analysed. A comparison is attempted with the results of the theoretical analysis of Seminara Colombini and Parker [4] and Stecca

  3. Sex-sorting sperm using flow cytometry/cell sorting.

    Science.gov (United States)

    Garner, Duane L; Evans, K Michael; Seidel, George E

    2013-01-01

    The sex of mammalian offspring can be predetermined by flow sorting relatively pure living populations of X- and Y-chromosome-bearing sperm. This method is based on precise staining of the DNA of sperm with the nucleic acid-specific fluorophore, Hoechst 33342, to differentiate between the subpopulations of X- and Y-sperm. The fluorescently stained sperm are then sex-sorted using a specialized high speed sorter, MoFlo(®) SX XDP, and collected into biologically supportive media prior to reconcentration and cryopreservation in numbers adequate for use with artificial insemination for some species or for in vitro fertilization. Sperm sorting can provide subpopulations of X- or Y-bearing bovine sperm at rates in the 8,000 sperm/s range while maintaining; a purity of 90% such that it has been applied to cattle on a commercial basis. The sex of offspring has been predetermined in a wide variety of mammalian species including cattle, swine, horses, sheep, goats, dogs, cats, deer, elk, dolphins, water buffalo as well as in humans using flow cytometric sorting of X- and Y-sperm.

  4. The effect of the solute on the structure, selected mechanical properties, and biocompatibility of Ti–Zr system alloys for dental applications

    Energy Technology Data Exchange (ETDEWEB)

    Correa, D.R.N.; Vicente, F.B. [UNESP — Univ. Estadual Paulista, Laboratório de Anelasticidade e Biomateriais, 17.033-360, Bauru, SP (Brazil); Donato, T.A.G.; Arana-Chavez, V.E. [USP — Universidade de São Paulo, Faculdade de Odontologia, Departamento de Biologia Oral e Biomateriais, 05.508-900, São Paulo, SP (Brazil); Buzalaf, M.A.R. [USP — Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Ciências Biológicas, 17.012-901, Bauru, SP (Brazil); Grandini, C.R., E-mail: betog@fc.unesp.br [UNESP — Univ. Estadual Paulista, Laboratório de Anelasticidade e Biomateriais, 17.033-360, Bauru, SP (Brazil)

    2014-01-01

    New titanium alloys have been developed with the aim of utilizing materials with better properties for application as biomaterials, and Ti–Zr system alloys are among the more promising of these. In this paper, the influence of zirconium concentrations on the structure, microstructure, and selected mechanical properties of Ti–Zr alloys is analyzed. After melting and swaging, the samples were characterized through chemical analysis, density measurements, X-ray diffraction, optical microscopy, Vickers microhardness, and elasticity modulus. In-vitro cytotoxicity tests were performed on cultured osteogenic cells. The results showed the formation essentially of the α′ phase (with hcp structure) and microhardness values greater than cp-Ti. The elasticity modulus of the alloys was sensitive to the zirconium concentrations while remaining within the range of values of conventional titanium alloys. The alloys presented no cytotoxic effects on osteoblastic cells in the studied conditions. - Highlights: • Ti–Zr alloys for biomedical applications were developed. • Only α′ phase was observed. • Influence of zirconium concentrations on the properties of Ti–Zr alloys was analyzed. • No cytotoxic effects were observed.

  5. The effect of the solute on the structure, selected mechanical properties, and biocompatibility of Ti–Zr system alloys for dental applications

    International Nuclear Information System (INIS)

    Correa, D.R.N.; Vicente, F.B.; Donato, T.A.G.; Arana-Chavez, V.E.; Buzalaf, M.A.R.; Grandini, C.R.

    2014-01-01

    New titanium alloys have been developed with the aim of utilizing materials with better properties for application as biomaterials, and Ti–Zr system alloys are among the more promising of these. In this paper, the influence of zirconium concentrations on the structure, microstructure, and selected mechanical properties of Ti–Zr alloys is analyzed. After melting and swaging, the samples were characterized through chemical analysis, density measurements, X-ray diffraction, optical microscopy, Vickers microhardness, and elasticity modulus. In-vitro cytotoxicity tests were performed on cultured osteogenic cells. The results showed the formation essentially of the α′ phase (with hcp structure) and microhardness values greater than cp-Ti. The elasticity modulus of the alloys was sensitive to the zirconium concentrations while remaining within the range of values of conventional titanium alloys. The alloys presented no cytotoxic effects on osteoblastic cells in the studied conditions. - Highlights: • Ti–Zr alloys for biomedical applications were developed. • Only α′ phase was observed. • Influence of zirconium concentrations on the properties of Ti–Zr alloys was analyzed. • No cytotoxic effects were observed

  6. Learning banknote fitness for sorting

    NARCIS (Netherlands)

    Geusebroek, J.M.; Markus, P.; Balke, P.

    2011-01-01

    In this work, a machine learning method is proposed for banknote soiling determination. We apply proven techniques from computer vision to come up with a robust and effective method for automatic sorting of banknotes. The proposed method is evaluated with respect to various invariance classes. The

  7. Quantum lower bound for sorting

    OpenAIRE

    Shi, Yaoyun

    2000-01-01

    We prove that \\Omega(n log(n)) comparisons are necessary for any quantum algorithm that sorts n numbers with high success probability and uses only comparisons. If no error is allowed, at least 0.110nlog_2(n) - 0.067n + O(1) comparisons must be made. The previous known lower bound is \\Omega(n).

  8. Sorting out river channel patterns

    NARCIS (Netherlands)

    Kleinhans, M.G.

    2010-01-01

    Rivers self-organize their pattern/planform through feedbacks between bars, channels, floodplain and vegetation, which emerge as a result of the basic spatial sorting process of wash load sediment and bed sediment. The balance between floodplain formation and destruction determines the width and

  9. The effect of remelting various combinations of new and used cobalt-chromium alloy on the mechanical properties and microstructure of the alloy

    Directory of Open Access Journals (Sweden)

    Sharad Gupta

    2012-01-01

    Conclusion: Repeated remelting of base metal alloy for dental casting without addition of new alloy can affect the mechanical properties of the alloy. Microstructure analysis shows deterioration upon remelting. However, the addition of 25% and 50% (by weight of new alloy to the remelted alloy can bring about improvement both in mechanical properties and in microstructure.

  10. Shape memory effect and super elasticity. Its dental applications.

    Science.gov (United States)

    Kotian, R

    2001-01-01

    The shape memory alloys are quite fascinating materials characterized by a shape memory effect and super elasticity which ordinary metals do not have. This unique behaviour was first found in a Au-47.5 at % Cd alloy in 1951, and was published in 1963 by the discovery of Ti-Ni alloy. Shape memory alloys now being practically used as new functional alloys for various dental and medical applications.

  11. Sorting fluorescent nanocrystals with DNA

    Energy Technology Data Exchange (ETDEWEB)

    Gerion, Daniele; Parak, Wolfgang J.; Williams, Shara C.; Zanchet, Daniela; Micheel, Christine M.; Alivisatos, A. Paul

    2001-12-10

    Semiconductor nanocrystals with narrow and tunable fluorescence are covalently linked to oligonucleotides. These biocompounds retain the properties of both nanocrystals and DNA. Therefore, different sequences of DNA can be coded with nanocrystals and still preserve their ability to hybridize to their complements. We report the case where four different sequences of DNA are linked to four nanocrystal samples having different colors of emission in the range of 530-640 nm. When the DNA-nanocrystal conjugates are mixed together, it is possible to sort each type of nanoparticle using hybridization on a defined micrometer -size surface containing the complementary oligonucleotide. Detection of sorting requires only a single excitation source and an epifluorescence microscope. The possibility of directing fluorescent nanocrystals towards specific biological targets and detecting them, combined with their superior photo-stability compared to organic dyes, opens the way to improved biolabeling experiments, such as gene mapping on a nanometer scale or multicolor microarray analysis.

  12. Flow cytogenetics and chromosome sorting.

    Science.gov (United States)

    Cram, L S

    1990-06-01

    This review of flow cytogenetics and chromosome sorting provides an overview of general information in the field and describes recent developments in more detail. From the early developments of chromosome analysis involving single parameter or one color analysis to the latest developments in slit scanning of single chromosomes in a flow stream, the field has progressed rapidly and most importantly has served as an important enabling technology for the human genome project. Technological innovations that advanced flow cytogenetics are described and referenced. Applications in basic cell biology, molecular biology, and clinical investigations are presented. The necessary characteristics for large number chromosome sorting are highlighted. References to recent review articles are provided as a starting point for locating individual references that provide more detail. Specific references are provided for recent developments.

  13. School accountability Incentives or sorting?

    OpenAIRE

    Hege Marie Gjefsen; Trude Gunnes

    2015-01-01

    We exploit a nested school accountability reform to estimate the causal effect on teacher mobility, sorting, and student achievement. In 2003, lower-secondary schools in Oslo became accountable to the school district authority for student achievement. In 2005, information on school performance in lower secondary education also became public. Using a difference-in-difference-in-difference approach, we find a significant increase in teacher mobility and that almost all non-stayers leave the tea...

  14. External parallel sorting with multiprocessor computers

    International Nuclear Information System (INIS)

    Comanceau, S.I.

    1984-01-01

    This article describes methods of external sorting in which the entire main computer memory is used for the internal sorting of entries, forming out of them sorted segments of the greatest possible size, and outputting them to external memories. The obtained segments are merged into larger segments until all entries form one ordered segment. The described methods are suitable for sequential files stored on magnetic tape. The needs of the sorting algorithm can be met by using the relatively slow peripheral storage devices (e.g., tapes, disks, drums). The efficiency of the external sorting methods is determined by calculating the total sorting time as a function of the number of entries to be sorted and the number of parallel processors participating in the sorting process

  15. Sorting and selection in posets

    DEFF Research Database (Denmark)

    Daskalakis, Constantinos; Karp, Richard M.; Mossel, Elchanan

    2011-01-01

    from two decades ago by Faigle and Turán. In particular, we present the first algorithm that sorts a width-$w$ poset of size $n$ with query complexity $O(n(w+\\log n))$ and prove that this query complexity is asymptotically optimal. We also describe a variant of Mergesort with query complexity $O......(wn\\log\\frac{n}{w})$ and total complexity $O(w^{2}n\\log\\frac{n}{w})$; an algorithm with the same query complexity was given by Faigle and Turán, but no efficient implementation of that algorithm is known. Both our sorting algorithms can be applied with negligible overhead to the more general problem of reconstructing transitive......Classical problems of sorting and searching assume an underlying linear ordering of the objects being compared. In this paper, we study these problems in the context of partially ordered sets, in which some pairs of objects are incomparable. This generalization is interesting from a combinatorial...

  16. Perbandingan Bubble Sort dengan Insertion Sort pada Bahasa Pemrograman C dan Fortran

    Directory of Open Access Journals (Sweden)

    Reina Reina

    2013-12-01

    Full Text Available Sorting is a basic algorithm studied by students of computer science major. Sorting algorithm is the basis of other algorithms such as searching algorithm, pattern matching algorithm. Bubble sort is a popular basic sorting algorithm due to its easiness to be implemented. Besides bubble sort, there is insertion sort. It is lesspopular than bubble sort because it has more difficult algorithm. This paper discusses about process time between insertion sort and bubble sort with two kinds of data. First is randomized data, and the second is data of descending list. Comparison of process time has been done in two kinds of programming language that is C programming language and FORTRAN programming language. The result shows that bubble sort needs more time than insertion sort does.

  17. Effects of TiN coating on the corrosion of nanostructured Ti-30Ta-xZr alloys for dental implants

    Science.gov (United States)

    Kim, Won-Gi; Choe, Han-Cheol

    2012-01-01

    Electrochemical characteristics of a titanium nitride (TiN)-coated/nanotube-formed Ti-Ta-Zr alloy for biomaterials have been researched by using the magnetic sputter and electrochemical methods. Ti-30Ta-xZr (x = 3, 7 and 15 wt%) alloys were prepared by arc melting and heat treated for 24 h at 1000 °C in an argon atmosphere and then water quenching. The formation of oxide nanotubes was achieved by anodizing a Ti-30Ta-xZr alloy in H3PO4 electrolytes containing small amounts of fluoride ions at room temperature. Anodization was carried out using a scanning potentiostat, and all experiments were conducted at room temperature. The microstructure and morphology of nanotube arrays were characterized by optical microscopy (OM), field emission scanning electron microscopy (FE-SEM) and X-ray diffraction (XRD). The TiN coatings were obtained by the radio-frequency (RF) magnetron sputtering technique. The depositions were performed from pure Ti targets on Ti-30Ta-xZr alloys substrates. The corrosion properties of the specimens were examined using potentiodynamic test in a 0.9% NaCl solution by using potentiostat. The microstructures of Ti-30Ta-xZr alloys were changed from an equiaxed to a needle-like structure with increasing Zr content. The interspace between the nanotubes was approximately 20, 80 and 200 nm for Zr contents of 3, 7 and 15 wt%, respectively. The corrosion resistance of the TiN-coated on the anodized Ti-30Ta-xZr alloys was higher than that of the untreated Ti alloys, indicating a better protective effect.

  18. Word Sorts for General Music Classes

    Science.gov (United States)

    Cardany, Audrey Berger

    2015-01-01

    Word sorts are standard practice for aiding children in acquiring skills in English language arts. When included in the general music classroom, word sorts may aid students in acquiring a working knowledge of music vocabulary. The author shares a word sort activity drawn from vocabulary in John Lithgow's children's book "Never Play…

  19. Osseointegration of loaded dental implant with KrF laser hydroxylapatite films on Ti6Al4V alloy by minipigs

    Czech Academy of Sciences Publication Activity Database

    Dostálová, T.; Jelínek, Miroslav; Grivas, C.

    2001-01-01

    Roč. 6, č. 2 (2001), s. 239-243 ISSN 1083-3668 Institutional research plan: CEZ:AV0Z1010914 Keywords : osseointegration * titanium alloy * KrF laser Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.292, year: 2001

  20. Energy efficient data sorting using standard sorting algorithms

    KAUST Repository

    Bunse, Christian; Hö pfner, Hagen; Roychoudhury, Suman; Mansour, Essam

    2011-01-01

    Protecting the environment by saving energy and thus reducing carbon dioxide emissions is one of todays hottest and most challenging topics. Although the perspective for reducing energy consumption, from ecological and business perspectives is clear, from a technological point of view, the realization especially for mobile systems still falls behind expectations. Novel strategies that allow (software) systems to dynamically adapt themselves at runtime can be effectively used to reduce energy consumption. This paper presents a case study that examines the impact of using an energy management component that dynamically selects and applies the "optimal" sorting algorithm, from an energy perspective, during multi-party mobile communication. Interestingly, the results indicate that algorithmic performance is not key and that dynamically switching algorithms at runtime does have a significant impact on energy consumption. © Springer-Verlag Berlin Heidelberg 2011.

  1. About Dental Amalgam Fillings

    Science.gov (United States)

    ... and Medical Procedures Dental Devices Dental Amalgam About Dental Amalgam Fillings Share Tweet Linkedin Pin it More ... should I have my fillings removed? What is dental amalgam? Dental amalgam is a dental filling material ...

  2. Dental cavities

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001055.htm Dental cavities To use the sharing features on this page, please enable JavaScript. Dental cavities are holes (or structural damage) in the ...

  3. Dental sealants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000779.htm Dental sealants To use the sharing features on this ... case a sealant needs to be replaced. How Dental Sealants are Applied Your dentist applies sealants on ...

  4. Fixing the Sorting Algorithm for Android, Java and Python

    NARCIS (Netherlands)

    C.P.T. de Gouw (Stijn); F.S. de Boer (Frank)

    2015-01-01

    htmlabstractTim Peters developed the Timsort hybrid sorting algorithm in 2002. TimSort was first developed for Python, a popular programming language, but later ported to Java (where it appears as java.util.Collections.sort and java.util.Arrays.sort). TimSort is today used as the default sorting

  5. Dental negligence.

    Science.gov (United States)

    Tay, C S

    2000-02-01

    Medical and dental errors and negligence are again in the spotlight in recent news report. Dead because of doctor's bad handwriting Prescribing drug overdoses Germ-infested soap pumps--infections in hospitals This articles explains dental negligence including dental duty of care and the standard of care expected of dentists in relation to the Bolam principle.

  6. Application of visible spectroscopy in waste sorting

    Science.gov (United States)

    Spiga, Philippe; Bourely, Antoine

    2011-10-01

    Today, waste recycling, (bottles, papers...), is a mechanical operation: the waste are crushed, fused and agglomerated in order to obtain new manufactured products (e.g. new bottles, clothes ...). The plastics recycling is the main application in the color sorting process. The colorless plastics recovered are more valuable than the colored plastics. Other emergent applications are in the paper sorting, where the main goal is to sort dyed paper from white papers. Up to now, Pellenc Selective Technologies has manufactured color sorting machines based on RGB cameras. Three dimensions (red, green and blue) are no longer sufficient to detect low quantities of dye in the considered waste. In order to increase the efficiency of the color detection, a new sorting machine, based on visible spectroscopy, has been developed. This paper presents the principles of the two approaches and their difference in terms of sorting performance, making visible spectroscopy a clear winner.

  7. In vitro evaluation of cytotoxicity and corrosion behavior of commercially pure titanium and Ti-6Al-4V alloy for dental implants.

    Science.gov (United States)

    Chandar, Sanchitha; Kotian, Ravindra; Madhyastha, Prashanthi; Kabekkodu, Shama Prasada; Rao, Padmalatha

    2017-01-01

    The aim of this study was to investigate the cytotoxicity in human gingival fibroblast by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay and corrosion behavior by potentiodynamic polarization technique of commercially pure titanium (Ti 12) and its alloy Ti-6Al-4V (Ti 31). In the present in vitro study, cytotoxicity of Ti 12 and Ti 31 in human gingival fibroblast by MTT assay and the corrosion behavior by potentiodynamic polarization technique in aqueous solutions of 0.1 N NaCl, 0.1 N KCl, and artificial saliva with and without NaF were studied. The independent t -test within materials and paired t-test with time interval showed higher cell viability for Ti 12 compared to Ti 31. Over a period, cell viability found to stabilize in both Ti 12 and Ti 31. The effects of ions of Ti and alloying elements aluminum and vanadium on the cell viability were found with incubation period of cells on samples to 72 h. The electrochemical behavior of Ti 12 and Ti 31 in different experimental solutions showed a general tendency for the immersion potential to shift steadily toward nobler values indicated formation of TiO 2 and additional metal oxides. The multiphase alloy Ti-6Al-4V showed more surface pitting. The commercially pure Ti showed better cell viability compared to Ti 31. Less cell viability in Ti 31 is because of the presence of aluminum and vanadium. A significant decrease in cytotoxicity due to the formation of TiO 2 over a period of time was observed both in Ti 12 and Ti 31. The electrochemical behavior of Ti 12 and Ti 31 in different experimental solutions showed a general tendency for the immersion potential to shift steadily toward nobler values indicated formation of TiO2 and additional metal oxides. Ti 31 alloy showed surface pitting because of its multiphase structure.

  8. Study of the microstructural and mechanical properties of titanium-niobium-zirconium based alloys processed with hydrogen and powder metallurgy for use in dental implants

    International Nuclear Information System (INIS)

    Duvaizem, Jose Helio

    2009-01-01

    Hydrogen has been used as pulverization agent in alloys based on rare earth and transition metals due to its extremely high diffusion rate even on low temperatures. Such materials are used on hydrogen storage dispositives, generation of electricity or magnetic fields, and are produced by a process which the first step is the transformation of the alloy in fine powder by miling. Besides those, hydrogenium is also being used to obtain alloys based on titanium - niobium - zirconium in the pulverization. Powder metallurgy is utilized on the production of these alloys, making it possible to obtain structures with porous surface as result, requirement for its application as biomaterials. Other advantages of powder metallurgy usage include better surface finish and better microstructural homogeneity. In this work samples were prepared in the Ti-13Nb-13Zr composition. The hydrogenation was performed at 700 degree C, 600 degree C, and 500 degree C for titanium, niobium and zirconium respectively. After hydrogenation, the milling stage was carried out on high energy planetary ball milling with 200rpm during 90 minutes, and also in conventional ball milling for 30 hours. Samples were pressed in uniaxial press, followed by isostatic cold press, and then sintered at 1150 degree C for 7-13 hours. Microstructural properties of the samples were characterized by scanning electron microscope (SEM), energy dispersive spectroscopy (EDS) and x-ray diffraction. Mechanical and structural properties determined were density, microhardness and moduli of elasticity. The sample sintered at 1150 degree C for 7h, hydrogenated using 10.000 mbar and produced by milling on high energy planetary ball milling presented the best mechanical properties and microstructural homogeneity. (author)

  9. Identification and sorting of materials with portable LIBS before decommissioning

    International Nuclear Information System (INIS)

    Vors, Evelyne; Sirven, Jean-Baptiste; Dehayem-Massop, Alix; Gallou, Guillaume

    2016-01-01

    Laser Induced Breakdown Spectroscopy (LIBS) is a technique of elemental analysis. A laser beam is focused on the surface of the sample to be analyzed. A small quantity of matter is ablated and a plasma formed by the atomized compounds is created. The spectral lines of the light emitted by the plasma are detected by an optical spectrometer. LIBS is a fully optical, multi-elementary and fast analytical technique, requiring no or little sample preparation. These features make the LIBS technique particularly suited for in situ measurements, and portable instruments are currently developed. LIBS analysis can be applied to the identification of materials using chemometric statistical methods (multivariate analysis) connecting the spectrum to the nature of the sample. Such methods have been successfully applied in our laboratory to the determination of the geographical origin of yellow cakes and to the identification of alloys. We present here the work performed with a portable LIBS instrument to meet the needs of waste sorting in industrial domain and in nuclear domain (inventory before decommissioning). A data base of LIBS spectra was built with a commercial instrument (IVEA SAS Easylibs) with samples of four categories of interest for industrial waste sorting: alloys, plastics, concrete and glasses. Different correct identification rates are requested by categories. The alloy spectra contain characteristic spectral lines and sub-categories can be easily discriminated (for example, different steel classes can be identified). The components of the plastics (mainly C, H, O and N) give rise to less characteristic lines and the plastics identification requires a separate study. Supervised statistical models are built with the data base spectra and predictions are instantly calculated for the spectra of unknown materials to identify in order to direct them to the correct waste stream. (authors)

  10. On the Construction of Sorted Reactive Systems

    DEFF Research Database (Denmark)

    Birkedal, Lars; Debois, Søren; Hildebrandt, Thomas

    2008-01-01

    We develop a theory of sorted bigraphical reactive systems. Every application of bigraphs in the literature has required an extension, a sorting, of pure bigraphs. In turn, every such application has required a redevelopment of the theory of pure bigraphical reactive systems for the sorting at hand...... bigraphs. Technically, we give our construction for ordinary reactive systems, then lift it to bigraphical reactive systems. As such, we give also a construction of sortings for ordinary reactive systems. This construction is an improvement over previous attempts in that it produces smaller and much more...

  11. Design and realization of sort manipulator of crystal-angle sort machine

    Science.gov (United States)

    Wang, Ming-shun; Chen, Shu-ping; Guan, Shou-ping; Zhang, Yao-wei

    2005-12-01

    It is a current tendency of development in automation technology to replace manpower with manipulators in working places where dangerous, harmful, heavy or repetitive work is involved. The sort manipulator is installed in a crystal-angle sort machine to take the place of manpower, and engaged in unloading and sorting work. It is the outcome of combing together mechanism, electric transmission, and pneumatic element and micro-controller control. The step motor makes the sort manipulator operate precisely. The pneumatic elements make the sort manipulator be cleverer. Micro-controller's software bestows some simple artificial intelligence on the sort manipulator, so that it can precisely repeat its unloading and sorting work. The combination of manipulator's zero position and step motor counting control puts an end to accumulating error in long time operation. A sort manipulator's design in the practice engineering has been proved to be correct and reliable.

  12. 21 CFR 872.3080 - Mercury and alloy dispenser.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mercury and alloy dispenser. 872.3080 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3080 Mercury and alloy dispenser. (a) Identification. A mercury and alloy dispenser is a device with a spring-activated valve intended to measure and...

  13. In vitro evaluation of cytotoxicity and corrosion behavior of commercially pure titanium and Ti-6Al-4V alloy for dental implants

    Directory of Open Access Journals (Sweden)

    Sanchitha Chandar

    2017-01-01

    Conclusion: The commercially pure Ti showed better cell viability compared to Ti 31. Less cell viability in Ti 31 is because of the presence of aluminum and vanadium. A significant decrease in cytotoxicity due to the formation of TiO2over a period of time was observed both in Ti 12 and Ti 31. The electrochemical behavior of Ti 12 and Ti 31 in different experimental solutions showed a general tendency for the immersion potential to shift steadily toward nobler values indicated formation of TiO2 and additional metal oxides. Ti 31 alloy showed surface pitting because of its multiphase structure.

  14. Enhancement of Selection, Bubble and Insertion Sorting Algorithm

    OpenAIRE

    Muhammad Farooq Umar; Ehsan Ullah Munir; Shafqat Ali Shad; Muhammad Wasif Nisar

    2014-01-01

    In everyday life there is a large amount of data to arrange because sorting removes any ambiguities and make the data analysis and data processing very easy, efficient and provides with cost less effort. In this study a set of improved sorting algorithms are proposed which gives better performance and design idea. In this study five new sorting algorithms (Bi-directional Selection Sort, Bi-directional bubble sort, MIDBiDirectional Selection Sort, MIDBidirectional bubble sort and linear insert...

  15. Surface acoustic wave actuated cell sorting (SAWACS).

    Science.gov (United States)

    Franke, T; Braunmüller, S; Schmid, L; Wixforth, A; Weitz, D A

    2010-03-21

    We describe a novel microfluidic cell sorter which operates in continuous flow at high sorting rates. The device is based on a surface acoustic wave cell-sorting scheme and combines many advantages of fluorescence activated cell sorting (FACS) and fluorescence activated droplet sorting (FADS) in microfluidic channels. It is fully integrated on a PDMS device, and allows fast electronic control of cell diversion. We direct cells by acoustic streaming excited by a surface acoustic wave which deflects the fluid independently of the contrast in material properties of deflected objects and the continuous phase; thus the device underlying principle works without additional enhancement of the sorting by prior labelling of the cells with responsive markers such as magnetic or polarizable beads. Single cells are sorted directly from bulk media at rates as fast as several kHz without prior encapsulation into liquid droplet compartments as in traditional FACS. We have successfully directed HaCaT cells (human keratinocytes), fibroblasts from mice and MV3 melanoma cells. The low shear forces of this sorting method ensure that cells survive after sorting.

  16. Algorithm 426 : Merge sort algorithm [M1

    NARCIS (Netherlands)

    Bron, C.

    1972-01-01

    Sorting by means of a two-way merge has a reputation of requiring a clerically complicated and cumbersome program. This ALGOL 60 procedure demonstrates that, using recursion, an elegant and efficient algorithm can be designed, the correctness of which is easily proved [2]. Sorting n objects gives

  17. Engineering a Cache-Oblivious Sorting Algorithm

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Fagerberg, Rolf; Vinther, Kristoffer

    2007-01-01

    This paper is an algorithmic engineering study of cache-oblivious sorting. We investigate by empirical methods a number of implementation issues and parameter choices for the cache-oblivious sorting algorithm Lazy Funnelsort, and compare the final algorithm with Quicksort, the established standard...

  18. Heuristic framework for parallel sorting computations | Nwanze ...

    African Journals Online (AJOL)

    Parallel sorting techniques have become of practical interest with the advent of new multiprocessor architectures. The decreasing cost of these processors will probably in the future, make the solutions that are derived thereof to be more appealing. Efficient algorithms for sorting scheme that are encountered in a number of ...

  19. Magnethophoretic sorting of fluid catalytic cracking particles

    NARCIS (Netherlands)

    Solsona, Miguel; Nieuwelink, A. E.; Odijk, Mathieu; Meirer, Florian; Abelmann, Leon; Olthuis, Wouter; Weckhuysen, Bert M.; van den Berg, Albert; Lee, Abraham; DeVoe, Don

    2017-01-01

    We demonstrate an on-chip particle activity sorter, focused on iron concentration and based on magnetophoresis. This device was used for fast sorting of stepwise homogenously distributed [Fe]s. The preliminary results are very encouraging. We show that we can sort particles on magnetic moment, with

  20. Data parallel sorting for particle simulation

    Science.gov (United States)

    Dagum, Leonardo

    1992-01-01

    Sorting on a parallel architecture is a communications intensive event which can incur a high penalty in applications where it is required. In the case of particle simulation, only integer sorting is necessary, and sequential implementations easily attain the minimum performance bound of O (N) for N particles. Parallel implementations, however, have to cope with the parallel sorting problem which, in addition to incurring a heavy communications cost, can make the minimun performance bound difficult to attain. This paper demonstrates how the sorting problem in a particle simulation can be reduced to a merging problem, and describes an efficient data parallel algorithm to solve this merging problem in a particle simulation. The new algorithm is shown to be optimal under conditions usual for particle simulation, and its fieldwise implementation on the Connection Machine is analyzed in detail. The new algorithm is about four times faster than a fieldwise implementation of radix sort on the Connection Machine.

  1. Data Sorting Using Graphics Processing Units

    Directory of Open Access Journals (Sweden)

    M. J. Mišić

    2012-06-01

    Full Text Available Graphics processing units (GPUs have been increasingly used for general-purpose computation in recent years. The GPU accelerated applications are found in both scientific and commercial domains. Sorting is considered as one of the very important operations in many applications, so its efficient implementation is essential for the overall application performance. This paper represents an effort to analyze and evaluate the implementations of the representative sorting algorithms on the graphics processing units. Three sorting algorithms (Quicksort, Merge sort, and Radix sort were evaluated on the Compute Unified Device Architecture (CUDA platform that is used to execute applications on NVIDIA graphics processing units. Algorithms were tested and evaluated using an automated test environment with input datasets of different characteristics. Finally, the results of this analysis are briefly discussed.

  2. Big Five Measurement via Q-Sort

    Directory of Open Access Journals (Sweden)

    Chris D. Fluckinger

    2014-08-01

    Full Text Available Socially desirable responding presents a difficult challenge in measuring personality. I tested whether a partially ipsative measure—a normatively scored Q-sort containing traditional Big Five items—would produce personality scores indicative of less socially desirable responding compared with Likert-based measures. Across both instructions to respond honestly and in the context of applying for a job, the Q-sort produced lower mean scores, lower intercorrelations between dimensions, and similar validity in predicting supervisor performance ratings to Likert. In addition, the Q-sort produced a more orthogonal structure (but not fully orthogonal when modeled at the latent level. These results indicate that the Q-sort method did constrain socially desirable responding. Researchers and practitioners should consider Big Five measurement via Q-sort for contexts in which high socially desirable responding is expected.

  3. IMPLEMENTATION OF SERIAL AND PARALLEL BUBBLE SORT ON FPGA

    Directory of Open Access Journals (Sweden)

    Dwi Marhaendro Jati Purnomo

    2016-06-01

    Full Text Available Sorting is common process in computational world. Its utilization are on many fields from research to industry. There are many sorting algorithm in nowadays. One of the simplest yet powerful is bubble sort. In this study, bubble sort is implemented on FPGA. The implementation was taken on serial and parallel approach. Serial and parallel bubble sort then compared by means of its memory, execution time, and utility which comprises slices and LUTs. The experiments show that serial bubble sort required smaller memory as well as utility compared to parallel bubble sort. Meanwhile, parallel bubble sort performed faster than serial bubble sort

  4. Ceramic Defects in Metal-Ceramic Fixed Dental Prostheses Made from Co-Cr and Au-Pt Alloys: A Retrospective Study.

    Science.gov (United States)

    Mikeli, Aikaterini; Boening, Klaus W; Lißke, Benjamin

    2015-01-01

    Ceramic defects in porcelain-fused-to-metal (PFM) restorations may depend on framework alloy type. This study assessed ceramic defects on cobalt-chromium- (Co-Cr-) and gold-platinum- (Au-Pt-) based PFM restorations. In this study, 147 Co-Cr-based and 168 Au-Pt-based PFM restorations inserted between 1998 and 2010 (139 patients) were examined for ceramic defects. Detected defects were assigned to three groups according to clinical defect relevance. Ceramic defect rates (Co-Cr-based: 12.9%; Au-Pt-based: 7.2%) revealed no significant difference but a strong statistical trend (U test, P = .082). Most defects were of little clinical relevance. Co-Cr PFM restorations may be at higher risk for ceramic defects compared to Au-Pt-based restorations.

  5. An Unsupervised Online Spike-Sorting Framework.

    Science.gov (United States)

    Knieling, Simeon; Sridharan, Kousik S; Belardinelli, Paolo; Naros, Georgios; Weiss, Daniel; Mormann, Florian; Gharabaghi, Alireza

    2016-08-01

    Extracellular neuronal microelectrode recordings can include action potentials from multiple neurons. To separate spikes from different neurons, they can be sorted according to their shape, a procedure referred to as spike-sorting. Several algorithms have been reported to solve this task. However, when clustering outcomes are unsatisfactory, most of them are difficult to adjust to achieve the desired results. We present an online spike-sorting framework that uses feature normalization and weighting to maximize the distinctiveness between different spike shapes. Furthermore, multiple criteria are applied to either facilitate or prevent cluster fusion, thereby enabling experimenters to fine-tune the sorting process. We compare our method to established unsupervised offline (Wave_Clus (WC)) and online (OSort (OS)) algorithms by examining their performance in sorting various test datasets using two different scoring systems (AMI and the Adamos metric). Furthermore, we evaluate sorting capabilities on intra-operative recordings using established quality metrics. Compared to WC and OS, our algorithm achieved comparable or higher scores on average and produced more convincing sorting results for intra-operative datasets. Thus, the presented framework is suitable for both online and offline analysis and could substantially improve the quality of microelectrode-based data evaluation for research and clinical application.

  6. Structural characterization and electrochemical behavior of 45S5 bioglass coating on Ti6Al4V alloy for dental applications

    Energy Technology Data Exchange (ETDEWEB)

    López, M.M. Machado, E-mail: machadolopez23@gmail.com [Instituto de Investigaciones Metalúrgicas, Universidad Michoacana de San Nicolás de Hidalgo, C.U. Edificio “U”, C.P. 58000, Morelia, Michoacán, México (Mexico); Fauré, J. [Laboratoire Ingénierie et Sciences des Matériaux (LISM EA 4695) - Université de Reims Champagne-Ardenne, 21 rue Clément Ader, Reims, BP 138 Cedex 02, 51685 France (France); Cabrera, M.I. Espitia [Facultad de ingeniería Química, Universidad Michoacana de San Nicolás de Hidalgo, C.U. Edificio “D”, C.P. 58000, Morelia, Michoacán, México (Mexico); García, M.E. Contreras, E-mail: eucontre@umich.mx [Instituto de Investigaciones Metalúrgicas, Universidad Michoacana de San Nicolás de Hidalgo, C.U. Edificio “U”, C.P. 58000, Morelia, Michoacán, México (Mexico)

    2016-04-15

    Graphical abstract: - Highlights: • Bioglass 45S5 nanostructured films were obtained by colloidal electrophoretic deposition (CEDP) method, proposed in this work, on Ti6Al4 V substrates. • Ti6Al4 V corrosion resistance in Hank's solution was increased with bioglass 45S5 coating. • Crystalline phases of 45S5 bioglass xerogels were obtained and characterized by XRD. • The model of chemical anchoring between Ti6Al4 V and bioglass 45S5 is proposed. - Abstract: In the present work, 45S5 bioglass coatings were deposited on the Ti6Al4 V alloy substrate through the cathodic colloidal electrophoretic deposition process (CEDP) proposed in this work. The coatings were thermally treated at temperatures of 500, 600, 700, and 800 °C for 2 h, and their structure was characterized by FESEM and DRX. Nanostructure and phase evolution of the coatings and xerogels was followed as a function of temperature. The corrosion resistance of the Ti6Al4 V alloy and the 45S5/Ti6Al4 V coating was studied by means of Tafel extrapolation in Hank's solution, at 37 °C, simulating the conditions inside the mouth. The 45S5 bioglass coatings displayed an amorphous nanostructure at lower temperatures, and partial crystallization at higher temperatures. An increase in the corrosion resistance was observed in the 45S5/Ti6l4 V coating treated at 700 °C because it reduced the i{sub corr}, and there was a change in the E{sub corr} towards more noble values. A model of the chemical anchorage of the 45S5 bioglass coating on Ti6Al4 V was proposed.

  7. The Q sort theory and technique.

    Science.gov (United States)

    Nyatanga, L

    1989-10-01

    This paper is based on the author's experience of using the Q sort technique with BA Social Sciences (BASS) students, and the community psychiatric nursing (CPN, ENB No 811 course). The paper focuses on two main issues: 1. The theoretical assumptions underpinning the Q Sort technique. Carl Rogers' self theory and some of the values of humanistic psychology are summarised. 2. The actual technique procedure and meaning of results are highlighted. As the Q Sort technique is potentially useful in a variety of sittings some of which are listed in this paper, the emphasis has deliberately been placed in understanding the theoretical underpinning and the operationalisation (sensitive interpretation) of the theory to practice.

  8. Development of sorting system control using LABVIEW

    International Nuclear Information System (INIS)

    Azraf Azman; Mohd Arif Hamzah; Noriah Mod Ali; John Konsoh; Mohd Idris Taib; Maslina Mohd Ibrahim; Nor Arymaswati Abdullah; Abu Bakar Mhd Ghazali

    2005-01-01

    The development of the Personnel Dosimeter Sorting System, proposed by the Secondary Standard Dosimetry Laboratory (SSDL) is to enhance the system or work flow in preparing the personnel dosimeter. The main objective of the system is to reduce stamping error, time and cost. The Personnel Dosimeter Sorting System is a semi-automatic system with an interfacing method using the Advantec 32 bit PCI interface card of 64 digital input and output. The system is integrated with the Labview version 7.1 programming language to control the sorting system and operation. (Author)

  9. On Sorting Genomes with DCJ and Indels

    Science.gov (United States)

    Braga, Marília D. V.

    A previous work of Braga, Willing and Stoye compared two genomes with unequal content, but without duplications, and presented a new linear time algorithm to compute the genomic distance, considering double cut and join (DCJ) operations, insertions and deletions. Here we derive from this approach an algorithm to sort one genome into another one also using DCJ, insertions and deletions. The optimal sorting scenarios can have different compositions and we compare two types of sorting scenarios: one that maximizes and one that minimizes the number of DCJ operations with respect to the number of insertions and deletions.

  10. Influence of metal dental materials on MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchihashi, Toshio; Chiba, Michiko; Yoshizawa, Satoshi; Sasaki, Sadayuki; Maki, Toshio; Kitagawa, Matsuo; Suzuki, Takeshi [Nippon Medical School, Tokyo (Japan). Main Hospital; Nakata, Minoru; Fujita, Isao

    1998-11-01

    Differences in magnetic susceptibility produce artifacts and signal loss in magnetic resonance imaging (MRI). This study was undertaken to compare the degree of artifacts on MRI caused by metallic dental materials. The influence on MRI of six types of dental alloys, a dental implant, orthodontic appliance, and magnetic attachment was investigated. Among the dental metals, nickel-chromium alloy and cobalt-chromium alloy, which have ferromagnetism, caused significant metal artifacts. Gold-platinum alloy, gold-silver-palladium alloy, silver alloy, and amalgam alloy produced slight metal artifacts. The orthodontic appliance mainly consisted of iron, and the keeper for its magnetic attachment was made of stainless steel. For these reasons, marked metal artifacts and signal loss could be seen in both of them owing to their ferromagnetism. These results suggest that orthodontic appliances and magnetic attachments impair evaluation of the GRE and EPI techniques. It is therefore preferable to use predominantly diamagnetic or paramagnetic dental materials for MRI of the head and neck. Removable keepers should be used more widely to prevent metal artifacts and enhance safety on MRI. (author)

  11. Influence of metal dental materials on MR imaging

    International Nuclear Information System (INIS)

    Tsuchihashi, Toshio; Chiba, Michiko; Yoshizawa, Satoshi; Sasaki, Sadayuki; Maki, Toshio; Kitagawa, Matsuo; Suzuki, Takeshi; Nakata, Minoru; Fujita, Isao

    1998-01-01

    Differences in magnetic susceptibility produce artifacts and signal loss in magnetic resonance imaging (MRI). This study was undertaken to compare the degree of artifacts on MRI caused by metallic dental materials. The influence on MRI of six types of dental alloys, a dental implant, orthodontic appliance, and magnetic attachment was investigated. Among the dental metals, nickel-chromium alloy and cobalt-chromium alloy, which have ferromagnetism, caused significant metal artifacts. Gold-platinum alloy, gold-silver-palladium alloy, silver alloy, and amalgam alloy produced slight metal artifacts. The orthodontic appliance mainly consisted of iron, and the keeper for its magnetic attachment was made of stainless steel. For these reasons, marked metal artifacts and signal loss could be seen in both of them owing to their ferromagnetism. These results suggest that orthodontic appliances and magnetic attachments impair evaluation of the GRE and EPI techniques. It is therefore preferable to use predominantly diamagnetic or paramagnetic dental materials for MRI of the head and neck. Removable keepers should be used more widely to prevent metal artifacts and enhance safety on MRI. (author)

  12. Pengembangan Algoritma Pengurutan SMS (Scan, Move, And Sort)

    OpenAIRE

    Lubis, Denni Aprilsyah

    2015-01-01

    Sorting has been a profound area for the algorithmic researchers. And many resources are invested to suggest a more working sorting algorithm. For this purpose many existing sorting algorithms were observed in terms of the efficiency of the algorithmic complexity. Efficient sorting is important to optimize the use of other algorithms that require sorted lists to work correctly. sorting has been considered as a fundamental problem in the study of algorithms that due to many reas...

  13. Implementation of Serial and Parallel Bubble Sort on Fpga

    OpenAIRE

    Purnomo, Dwi Marhaendro Jati; Arinaldi, Ahmad; Priyantini, Dwi Teguh; Wibisono, Ari; Febrian, Andreas

    2016-01-01

    Sorting is common process in computational world. Its utilization are on many fields from research to industry. There are many sorting algorithm in nowadays. One of the simplest yet powerful is bubble sort. In this study, bubble sort is implemented on FPGA. The implementation was taken on serial and parallel approach. Serial and parallel bubble sort then compared by means of its memory, execution time, and utility which comprises slices and LUTs. The experiments show that serial bubble sort r...

  14. NeatSort - A practical adaptive algorithm

    OpenAIRE

    La Rocca, Marcello; Cantone, Domenico

    2014-01-01

    We present a new adaptive sorting algorithm which is optimal for most disorder metrics and, more important, has a simple and quick implementation. On input $X$, our algorithm has a theoretical $\\Omega (|X|)$ lower bound and a $\\mathcal{O}(|X|\\log|X|)$ upper bound, exhibiting amazing adaptive properties which makes it run closer to its lower bound as disorder (computed on different metrics) diminishes. From a practical point of view, \\textit{NeatSort} has proven itself competitive with (and of...

  15. Investigation on adhering properties of dental materials by means of radioactively labelled bacteria

    International Nuclear Information System (INIS)

    Pfister, W.; Kleinert, P.; Sandig, H.C.; Wutzler, P.; Ruschitschka, A.; Schaefer, U.

    1987-01-01

    Bacteria of the species Streptococcus mutans were radioactively labelled with 113 In-oxinate. Different dental materials were incubated with the labelled bacteria. Counts per minute of the dental materials could be determined as proportion of the quantity of adhering microorganisms. Silver-palladium-alloy had a lower adherence than silver-tin-alloy. Finest polished alloys had lower adhering properties than unpolished surfaces of materials. (author)

  16. Automatic spike sorting using tuning information.

    Science.gov (United States)

    Ventura, Valérie

    2009-09-01

    Current spike sorting methods focus on clustering neurons' characteristic spike waveforms. The resulting spike-sorted data are typically used to estimate how covariates of interest modulate the firing rates of neurons. However, when these covariates do modulate the firing rates, they provide information about spikes' identities, which thus far have been ignored for the purpose of spike sorting. This letter describes a novel approach to spike sorting, which incorporates both waveform information and tuning information obtained from the modulation of firing rates. Because it efficiently uses all the available information, this spike sorter yields lower spike misclassification rates than traditional automatic spike sorters. This theoretical result is verified empirically on several examples. The proposed method does not require additional assumptions; only its implementation is different. It essentially consists of performing spike sorting and tuning estimation simultaneously rather than sequentially, as is currently done. We used an expectation-maximization maximum likelihood algorithm to implement the new spike sorter. We present the general form of this algorithm and provide a detailed implementable version under the assumptions that neurons are independent and spike according to Poisson processes. Finally, we uncover a systematic flaw of spike sorting based on waveform information only.

  17. The solution space of sorting by DCJ.

    Science.gov (United States)

    Braga, Marília D V; Stoye, Jens

    2010-09-01

    In genome rearrangements, the double cut and join (DCJ) operation, introduced by Yancopoulos et al. in 2005, allows one to represent most rearrangement events that could happen in multichromosomal genomes, such as inversions, translocations, fusions, and fissions. No restriction on the genome structure considering linear and circular chromosomes is imposed. An advantage of this general model is that it leads to considerable algorithmic simplifications compared to other genome rearrangement models. Recently, several works concerning the DCJ operation have been published, and in particular, an algorithm was proposed to find an optimal DCJ sequence for sorting one genome into another one. Here we study the solution space of this problem and give an easy-to-compute formula that corresponds to the exact number of optimal DCJ sorting sequences for a particular subset of instances of the problem. We also give an algorithm to count the number of optimal sorting sequences for any instance of the problem. Another interesting result is the demonstration of the possibility of obtaining one optimal sorting sequence by properly replacing any pair of consecutive operations in another optimal sequence. As a consequence, any optimal sorting sequence can be obtained from one other by applying such replacements successively, but the problem of finding the shortest number of replacements between two sorting sequences is still open.

  18. Dental OCT

    Science.gov (United States)

    Wilder-Smith, Petra; Otis, Linda; Zhang, Jun; Chen, Zhongping

    This chapter describes the applications of OCT for imaging in vivo dental and oral tissue. The oral cavity is a diverse environment that includes oral mucosa, gingival tissues, teeth and their supporting structures. Because OCT can image both hard and soft tissues of the oral cavity at high resolution, it offers the unique capacity to identity dental disease before destructive changes have progressed. OCT images depict clinically important anatomical features such as the location of soft tissue attachments, morphological changes in gingival tissue, tooth decay, enamel thickness and decay, as well as the structural integrity of dental restorations. OCT imaging allows for earlier intervention than is possible with current diagnostic modalities.

  19. Use of low fusing alloy in dentistry.

    Science.gov (United States)

    Wee, A G; Schneider, R L; Aquilino, S A

    1998-11-01

    Low fusing alloy has been used in dentistry for remount procedures in both fixed and removable prosthodontics, in implant prosthodontics for the fabrication of solid implant casts, in maxillofacial prosthetics as oral radiation shields, and in dental research for its unique properties. Previously, the use of low fusing alloy was thought to offer a high degree of dimensional accuracy. However, multiple in vitro studies have shown that its presumed dimensional accuracy may be questionable. This article reviews the physical properties, metallurgical considerations of low fusing alloy, its applications in dentistry, and a safe, simple method of using low fusing alloy.

  20. Infant dental care (image)

    Science.gov (United States)

    ... sugar water. As the child grows, establishing proper dental hygiene will promote healthy teeth and gums which are essential to overall good health. Poor dental development, dental disease, and dental trauma can result ...

  1. Fruit Sorting Using Fuzzy Logic Techniques

    Science.gov (United States)

    Elamvazuthi, Irraivan; Sinnadurai, Rajendran; Aftab Ahmed Khan, Mohamed Khan; Vasant, Pandian

    2009-08-01

    Fruit and vegetables market is getting highly selective, requiring their suppliers to distribute the goods according to very strict standards of quality and presentation. In the last years, a number of fruit sorting and grading systems have appeared to fulfill the needs of the fruit processing industry. However, most of them are overly complex and too costly for the small and medium scale industry (SMIs) in Malaysia. In order to address these shortcomings, a prototype machine was developed by integrating the fruit sorting, labeling and packing processes. To realise the prototype, many design issues were dealt with. Special attention is paid to the electronic weighing sub-system for measuring weight, and the opto-electronic sub-system for determining the height and width of the fruits. Specifically, this paper discusses the application of fuzzy logic techniques in the sorting process.

  2. Alloy materials

    Energy Technology Data Exchange (ETDEWEB)

    Hans Thieme, Cornelis Leo (Westborough, MA); Thompson, Elliott D. (Coventry, RI); Fritzemeier, Leslie G. (Acton, MA); Cameron, Robert D. (Franklin, MA); Siegal, Edward J. (Malden, MA)

    2002-01-01

    An alloy that contains at least two metals and can be used as a substrate for a superconductor is disclosed. The alloy can contain an oxide former. The alloy can have a biaxial or cube texture. The substrate can be used in a multilayer superconductor, which can further include one or more buffer layers disposed between the substrate and the superconductor material. The alloys can be made a by process that involves first rolling the alloy then annealing the alloy. A relatively large volume percentage of the alloy can be formed of grains having a biaxial or cube texture.

  3. MODELING WORK OF SORTING STATION USING UML

    Directory of Open Access Journals (Sweden)

    O. V. Gorbova

    2014-12-01

    Full Text Available Purpose. The purpose of this paper is the construction of methods and models for the graphical representation process of sorting station, using the unified modeling language (UML. Methodology. Methods of graph theory, finite automata and the representation theory of queuing systems were used as the methods of investigation. A graphical representation of the process was implemented with using the Unified Modeling Language UML. The sorting station process representation is implemented as a state diagram and actions through a set of IBM Rational Rose. Graphs can show parallel operation of sorting station, the parallel existence and influence of objects process and the transition from one state to another. The IBM Rational Rose complex allows developing a diagram of work sequence of varying degrees of detailing. Findings. The study has developed a graphical representation method of the process of sorting station of different kind of complexity. All graphical representations are made using the UML. They are represented as a directed graph with the states. It is clear enough in the study of the subject area. Applying the methodology of the representation process, it allows becoming friendly with the work of any automation object very fast, and exploring the process during algorithms construction of sorting stations and other railway facilities. This model is implemented with using the Unified Modeling Language (UML using a combination of IBM Rational Rose. Originality. The representation process of sorting station was developed by means of the Unified Modeling Language (UML use. Methodology of representation process allows creating the directed graphs based on the order of execution of the works chain, objects and performers of these works. The UML allows visualizing, specifying, constructing and documenting, formalizing the representation process of sorting station and developing sequence diagrams of works of varying degrees of detail. Practical

  4. Software information sorting code 'PLUTO-R'

    International Nuclear Information System (INIS)

    Tsunematsu, Toshihide; Naraoka, Kenitsu; Adachi, Masao; Takeda, Tatsuoki

    1984-10-01

    A software information sorting code PLUTO-R is developed as one of the supporting codes of the TRITON system for the fusion plasma analysis. The objective of the PLUTO-R code is to sort reference materials of the codes in the TRITON code system. The easiness in the registration of information is especially pursued. As experience and skill in the data registration are not required, this code is usable for construction of general small-scale information system. This report gives an overall description and the user's manual of the PLUTO-R code. (author)

  5. Application of radix sorting in high energy physics experiment

    International Nuclear Information System (INIS)

    Chen Xuan; Gu Minhao; Zhu Kejun

    2012-01-01

    In the high energy physics experiments, there are always requirements to sort the large scale of experiment data. To meet the demand, this paper introduces one radix sorting algorithms, whose sub-sort is counting sorting and time complex is O (n), based on the characteristic of high energy physics experiment data that is marked by time stamp. This paper gives the description, analysis, implementation and experimental result of the sorting algorithms. (authors)

  6. Dental Calculus Arrest of Dental Caries

    OpenAIRE

    Keyes, Paul H.; Rams, Thomas E.

    2016-01-01

    Background An inverse relationship between dental calculus mineralization and dental caries demineralization on teeth has been noted in some studies. Dental calculus may even form superficial layers over existing dental caries and arrest their progression, but this phenomenon has been only rarely documented and infrequently considered in the field of Cariology. To further assess the occurrence of dental calculus arrest of dental caries, this study evaluated a large number of extracted human t...

  7. Fifty years of Brazilian Dental Materials Group: scientific contributions of dental materials field evaluated by systematic review

    Science.gov (United States)

    ROSA, Wellington Luiz de Oliveira; SILVA, Tiago Machado; LIMA, Giana da Silveira; SILVA, Adriana Fernandes; PIVA, Evandro

    2016-01-01

    ABSTRACT Objective A systematic review was conducted to analyze Brazilian scientific and technological production related to the dental materials field over the past 50 years. Material and Methods This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (Prisma) statement. Searches were performed until December 2014 in six databases: MedLine (PubMed), Scopus, LILACS, IBECS, BBO, and the Cochrane Library. Additionally, the Brazilian patent database (INPI - Instituto Nacional de Propriedade Industrial) was screened in order to get an overview of Brazilian technological development in the dental materials field. Two reviewers independently analyzed the documents. Only studies and patents related to dental materials were included in this review. Data regarding the material category, dental specialty, number of documents and patents, filiation countries, and the number of citations were tabulated and analyzed in Microsoft Office Excel (Microsoft Corporation, Redmond, Washington, United States). Results A total of 115,806 studies and 53 patents were related to dental materials and were included in this review. Brazil had 8% affiliation in studies related to dental materials, and the majority of the papers published were related to dental implants (1,137 papers), synthetic resins (681 papers), dental cements (440 papers), dental alloys (392 papers) and dental adhesives (361 papers). The Brazilian technological development with patented dental materials was smaller than the scientific production. The most patented type of material was dental alloys (11 patents), followed by dental implants (8 patents) and composite resins (7 patents). Conclusions Dental materials science has had a substantial number of records, demonstrating an important presence in scientific and technological development of dentistry. In addition, it is important to approximate the relationship between academia and industry to expand the technological development in

  8. Fifty years of Brazilian Dental Materials Group: scientific contributions of dental materials field evaluated by systematic review.

    Science.gov (United States)

    Rosa, Wellington Luiz de Oliveira; Silva, Tiago Machado; Lima, Giana da Silveira; Silva, Adriana Fernandes; Piva, Evandro

    2016-01-01

    A systematic review was conducted to analyze Brazilian scientific and technological production related to the dental materials field over the past 50 years. This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (Prisma) statement. Searches were performed until December 2014 in six databases: MedLine (PubMed), Scopus, LILACS, IBECS, BBO, and the Cochrane Library. Additionally, the Brazilian patent database (INPI - Instituto Nacional de Propriedade Industrial) was screened in order to get an overview of Brazilian technological development in the dental materials field. Two reviewers independently analyzed the documents. Only studies and patents related to dental materials were included in this review. Data regarding the material category, dental specialty, number of documents and patents, filiation countries, and the number of citations were tabulated and analyzed in Microsoft Office Excel (Microsoft Corporation, Redmond, Washington, United States). A total of 115,806 studies and 53 patents were related to dental materials and were included in this review. Brazil had 8% affiliation in studies related to dental materials, and the majority of the papers published were related to dental implants (1,137 papers), synthetic resins (681 papers), dental cements (440 papers), dental alloys (392 papers) and dental adhesives (361 papers). The Brazilian technological development with patented dental materials was smaller than the scientific production. The most patented type of material was dental alloys (11 patents), followed by dental implants (8 patents) and composite resins (7 patents). Dental materials science has had a substantial number of records, demonstrating an important presence in scientific and technological development of dentistry. In addition, it is important to approximate the relationship between academia and industry to expand the technological development in countries such as Brazil.

  9. TECHNICAL EQUIPMENT FOR SORTING APPLES BY SIZE

    Directory of Open Access Journals (Sweden)

    Vasilica Ştefan

    2012-01-01

    Full Text Available Need to increase the competitiveness of semi-subsistence farms, by valorisation of the fruits, led to research for designing of an equipment for sorting apples by size, in order to meet market requirement, pricing according to the size of the fruits.

  10. Integration through a Card-Sort Activity

    Science.gov (United States)

    Green, Kris; Ricca, Bernard P.

    2015-01-01

    Learning to compute integrals via the various techniques of integration (e.g., integration by parts, partial fractions, etc.) is difficult for many students. Here, we look at how students in a college level Calculus II course develop the ability to categorize integrals and the difficulties they encounter using a card sort-resort activity. Analysis…

  11. A note on sorting buffrs offline

    NARCIS (Netherlands)

    Chan, H.L.; Megow, N.; Sitters, R.A.; van Stee, R.

    2012-01-01

    We consider the offline sorting buffer problem. The input is a sequence of items of different types. All items must be processed one by one by a server. The server is equipped with a random-access buffer of limited capacity which can be used to rearrange items. The problem is to design a scheduling

  12. A cargo-sorting DNA robot.

    Science.gov (United States)

    Thubagere, Anupama J; Li, Wei; Johnson, Robert F; Chen, Zibo; Doroudi, Shayan; Lee, Yae Lim; Izatt, Gregory; Wittman, Sarah; Srinivas, Niranjan; Woods, Damien; Winfree, Erik; Qian, Lulu

    2017-09-15

    Two critical challenges in the design and synthesis of molecular robots are modularity and algorithm simplicity. We demonstrate three modular building blocks for a DNA robot that performs cargo sorting at the molecular level. A simple algorithm encoding recognition between cargos and their destinations allows for a simple robot design: a single-stranded DNA with one leg and two foot domains for walking, and one arm and one hand domain for picking up and dropping off cargos. The robot explores a two-dimensional testing ground on the surface of DNA origami, picks up multiple cargos of two types that are initially at unordered locations, and delivers them to specified destinations until all molecules are sorted into two distinct piles. The robot is designed to perform a random walk without any energy supply. Exploiting this feature, a single robot can repeatedly sort multiple cargos. Localization on DNA origami allows for distinct cargo-sorting tasks to take place simultaneously in one test tube or for multiple robots to collectively perform the same task. Copyright © 2017, American Association for the Advancement of Science.

  13. Smoothsort, an alternative for sorting in situ

    NARCIS (Netherlands)

    Dijkstra, E.W.

    1982-01-01

    Like heapsort - which inspired it - smoothsort is an algorithm for sorting in situ. It is of order N · log N in the worst case, but of order N in the best case, with a smooth transition between the two. (Hence its name.)

  14. Passive sorting of capsules by deformability

    Science.gov (United States)

    Haener, Edgar; Juel, Anne

    We study passive sorting according to deformability of liquid-filled ovalbumin-alginate capsules. We present results for two sorting geometries: a straight channel with a half-cylindrical obstruction and a pinched flow fractioning device (PFF) adapted for use with capsules. In the half-cylinder device, the capsules deform as they encounter the obstruction, and travel around the half-cylinder. The distance from the capsule's centre of mass to the surface of the half-cylinder depends on deformability, and separation between capsules of different deformability is amplified by diverging streamlines in the channel expansion downstream of the obstruction. We show experimentally that capsules can be sorted according to deformability with their downstream position depending on capillary number only, and we establish the sensitivity of the device to experimental variability. In the PFF device, particles are compressed against a wall using a strong pinching flow. We show that capsule deformation increases with the intensity of the pinching flow, but that the downstream capsule position is not set by deformation in the device. However, when using the PFF device like a T-Junction, we achieve improved sorting resolution compared to the half-cylinder device.

  15. 6. Algorithms for Sorting and Searching

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 3. Algorithms - Algorithms for Sorting and Searching. R K Shyamasundar. Series Article ... Author Affiliations. R K Shyamasundar1. Computer Science Group, Tata Institute of Fundamental Research, Homi Bhabha Road, Mumbai 400 005, India ...

  16. Job Analysis Techniques for Restructuring Health Manpower Education and Training in the Navy Medical Department. Attachment 1. Radiation QPCB Task Sort for Radiation.

    Science.gov (United States)

    Technomics, Inc., McLean, VA.

    This publication is Attachment 1 of a set of 16 computer listed QPCB task sorts, by career level, for the entire Hospital Corps and Dental Technician fields. Statistical data are presented in tabular form for a detailed listing of job duties in radiation. (BT)

  17. Dental caries

    DEFF Research Database (Denmark)

    Pitts, Nigel B; Zero, Domenick T; Marsh, Phil D

    2017-01-01

    Dental caries is a biofilm-mediated, sugar-driven, multifactorial, dynamic disease that results in the phasic demineralization and remineralization of dental hard tissues. Caries can occur throughout life, both in primary and permanent dentitions, and can damage the tooth crown and, in later life......, exposed root surfaces. The balance between pathological and protective factors influences the initiation and progression of caries. This interplay between factors underpins the classification of individuals and groups into caries risk categories, allowing an increasingly tailored approach to care. Dental...... caries is an unevenly distributed, preventable disease with considerable economic and quality-of-life burdens. The daily use of fluoride toothpaste is seen as the main reason for the overall decline of caries worldwide over recent decades. This Primer aims to provide a global overview of caries...

  18. Recent research and development in titanium alloys for biomedical applications and healthcare goods

    Directory of Open Access Journals (Sweden)

    Mitsuo Niinomi

    2003-01-01

    Full Text Available Nb, Ta and Zr are the favorable non-toxic alloying elements for titanium alloys for biomedical applications. Low rigidity titanium alloys composed of non-toxic elements are getting much attention. The advantage of low rigidity titanium alloy for the healing of bone fracture and the remodeling of bone is successfully proved by fracture model made in tibia of rabbit. Ni-free super elastic and shape memory titanium alloys for biomedical applications are energetically developed. Titanium alloys for not only implants, but also dental products like crowns, dentures, etc. are also getting much attention in dentistry. Development of investment materials suitable for titanium alloys with high melting point is desired in dental precision castings. Bioactive surface modifications of titanium alloys for biomedical applications are very important for achieving further developed biocompatibility. Low cost titanium alloys for healthcare goods, like general wheel chairs, etc. has been recently proposed.

  19. Dental Calculus Arrest of Dental Caries.

    Science.gov (United States)

    Keyes, Paul H; Rams, Thomas E

    An inverse relationship between dental calculus mineralization and dental caries demineralization on teeth has been noted in some studies. Dental calculus may even form superficial layers over existing dental caries and arrest their progression, but this phenomenon has been only rarely documented and infrequently considered in the field of Cariology. To further assess the occurrence of dental calculus arrest of dental caries, this study evaluated a large number of extracted human teeth for the presence and location of dental caries, dental calculus, and dental plaque biofilms. A total of 1,200 teeth were preserved in 10% buffered formal saline, and viewed while moist by a single experienced examiner using a research stereomicroscope at 15-25× magnification. Representative teeth were sectioned and photographed, and their dental plaque biofilms subjected to gram-stain examination with light microscopy at 100× magnification. Dental calculus was observed on 1,140 (95%) of the extracted human teeth, and no dental carious lesions were found underlying dental calculus-covered surfaces on 1,139 of these teeth. However, dental calculus arrest of dental caries was found on one (0.54%) of 187 evaluated teeth that presented with unrestored proximal enamel caries. On the distal surface of a maxillary premolar tooth, dental calculus mineralization filled the outer surface cavitation of an incipient dental caries lesion. The dental calculus-covered carious lesion extended only slightly into enamel, and exhibited a brown pigmentation characteristic of inactive or arrested dental caries. In contrast, the tooth's mesial surface, without a superficial layer of dental calculus, had a large carious lesion going through enamel and deep into dentin. These observations further document the potential protective effects of dental calculus mineralization against dental caries.

  20. Dental Calculus Arrest of Dental Caries

    Science.gov (United States)

    Keyes, Paul H.; Rams, Thomas E.

    2016-01-01

    Background An inverse relationship between dental calculus mineralization and dental caries demineralization on teeth has been noted in some studies. Dental calculus may even form superficial layers over existing dental caries and arrest their progression, but this phenomenon has been only rarely documented and infrequently considered in the field of Cariology. To further assess the occurrence of dental calculus arrest of dental caries, this study evaluated a large number of extracted human teeth for the presence and location of dental caries, dental calculus, and dental plaque biofilms. Materials and methods A total of 1,200 teeth were preserved in 10% buffered formal saline, and viewed while moist by a single experienced examiner using a research stereomicroscope at 15-25× magnification. Representative teeth were sectioned and photographed, and their dental plaque biofilms subjected to gram-stain examination with light microscopy at 100× magnification. Results Dental calculus was observed on 1,140 (95%) of the extracted human teeth, and no dental carious lesions were found underlying dental calculus-covered surfaces on 1,139 of these teeth. However, dental calculus arrest of dental caries was found on one (0.54%) of 187 evaluated teeth that presented with unrestored proximal enamel caries. On the distal surface of a maxillary premolar tooth, dental calculus mineralization filled the outer surface cavitation of an incipient dental caries lesion. The dental calculus-covered carious lesion extended only slightly into enamel, and exhibited a brown pigmentation characteristic of inactive or arrested dental caries. In contrast, the tooth's mesial surface, without a superficial layer of dental calculus, had a large carious lesion going through enamel and deep into dentin. Conclusions These observations further document the potential protective effects of dental calculus mineralization against dental caries. PMID:27446993

  1. PhySortR: a fast, flexible tool for sorting phylogenetic trees in R.

    Science.gov (United States)

    Stephens, Timothy G; Bhattacharya, Debashish; Ragan, Mark A; Chan, Cheong Xin

    2016-01-01

    A frequent bottleneck in interpreting phylogenomic output is the need to screen often thousands of trees for features of interest, particularly robust clades of specific taxa, as evidence of monophyletic relationship and/or reticulated evolution. Here we present PhySortR, a fast, flexible R package for classifying phylogenetic trees. Unlike existing utilities, PhySortR allows for identification of both exclusive and non-exclusive clades uniting the target taxa based on tip labels (i.e., leaves) on a tree, with customisable options to assess clades within the context of the whole tree. Using simulated and empirical datasets, we demonstrate the potential and scalability of PhySortR in analysis of thousands of phylogenetic trees without a priori assumption of tree-rooting, and in yielding readily interpretable trees that unambiguously satisfy the query. PhySortR is a command-line tool that is freely available and easily automatable.

  2. ScanSort{sup SM} at Whiteshell Laboratories for sorting of experimental cesium pond soil

    Energy Technology Data Exchange (ETDEWEB)

    Downey, H., E-mail: heath.downey@amecfw.com [Amec Foster Wheeler, Portland, ME (United States)

    2015-07-01

    The ScanSort{sup SM} soil sorting system is a unique and efficient radiological instrument used for measuring and sorting bulk soils and volumetric materials. The system performs automatic radioassay and segregation of preconditioned material using a gamma spectroscopy system mounted above a conveyor belt. It was deployed to the Whiteshell Laboratories site to process the excavated soils generated during the decommissioning of the former Experimental Cesium Pond. The ScanSort{sup SM} system was utilized to segregate material with Cs-137 concentrations above the established site unrestricted release and restricted site reuse levels as well as demonstrated the ability to accurately determine the radioactivity concentrations of the radiologically-impacted material and to confidently segregate volumes of that material for appropriate final disposition. (author)

  3. [Compressive and bend strength of experimental admixed high copper alloys].

    Science.gov (United States)

    Sourai, P; Paximada, H; Lagouvardos, P; Douvitsas, G

    1988-01-01

    Mixed alloys for dental amalgams have been used mainly in the form of admixed alloys, where eutectic spheres are blend with conventional flakes. In the present study the compressive strength, bend strength and microstructure of two high-copper alloys (Tytin, Ana-2000) is compared with three experimental alloys prepared of the two high copper by mixing them in proportions of 3:1, 1:1 and 1:3 by weight. The results revealed that experimental alloys inherited high early and final strength values without any significant change in their microstructure.

  4. Sorting signed permutations by short operations.

    Science.gov (United States)

    Galvão, Gustavo Rodrigues; Lee, Orlando; Dias, Zanoni

    2015-01-01

    During evolution, global mutations may alter the order and the orientation of the genes in a genome. Such mutations are referred to as rearrangement events, or simply operations. In unichromosomal genomes, the most common operations are reversals, which are responsible for reversing the order and orientation of a sequence of genes, and transpositions, which are responsible for switching the location of two contiguous portions of a genome. The problem of computing the minimum sequence of operations that transforms one genome into another - which is equivalent to the problem of sorting a permutation into the identity permutation - is a well-studied problem that finds application in comparative genomics. There are a number of works concerning this problem in the literature, but they generally do not take into account the length of the operations (i.e. the number of genes affected by the operations). Since it has been observed that short operations are prevalent in the evolution of some species, algorithms that efficiently solve this problem in the special case of short operations are of interest. In this paper, we investigate the problem of sorting a signed permutation by short operations. More precisely, we study four flavors of this problem: (i) the problem of sorting a signed permutation by reversals of length at most 2; (ii) the problem of sorting a signed permutation by reversals of length at most 3; (iii) the problem of sorting a signed permutation by reversals and transpositions of length at most 2; and (iv) the problem of sorting a signed permutation by reversals and transpositions of length at most 3. We present polynomial-time solutions for problems (i) and (iii), a 5-approximation for problem (ii), and a 3-approximation for problem (iv). Moreover, we show that the expected approximation ratio of the 5-approximation algorithm is not greater than 3 for random signed permutations with more than 12 elements. Finally, we present experimental results that show

  5. Noble metal alloys for metal-ceramic restorations.

    Science.gov (United States)

    Anusavice, K J

    1985-10-01

    A review of the comparative characteristics and properties of noble metal alloys used for metal-ceramic restorations has been presented. Selection of an alloy for one's practice should be based on long-term clinical data, physical properties, esthetic potential, and laboratory data on metal-ceramic bond strength and thermal compatibility with commercial dental porcelains. Although gold-based alloys, such as the Au-Pt-Pd, Au-Pd-Ag, and Au-Pd classes, may appear to be costly compared with the palladium-based alloys, they have clearly established their clinical integrity and acceptability over an extended period of time. Other than the relatively low sag resistance of the high gold-low silver content alloys and the potential thermal incompatibility with some commercial porcelain products, few clinical failures have been observed. The palladium-based alloys are less costly than the gold-based alloys. Palladium-silver alloys require extra precautions to minimize porcelain discoloration. Palladium-copper and palladium-cobalt alloys may also cause porcelain discoloration, as copper and cobalt are used as colorants in glasses. The palladium-cobalt alloys are least susceptible to high-temperature creep compared with all classes of noble metals. Nevertheless, insufficient clinical data exist to advocate the general use of the palladium-copper and palladium-cobalt alloys at the present time. One should base the selection and use of these alloys in part on their ability to meet the requirements of the ADA Acceptance Program. A list of acceptable or provisionally acceptable alloys is available from the American Dental Association and is published annually in the Journal of the American Dental Association. Dentists have the legal and ethical responsibility for selection of alloys used for cast restorations. This responsibility should not be delegated to the dental laboratory technician. It is advisable to discuss the criteria for selection of an alloy with the technician and the

  6. A mower detector to judge soil sorting

    International Nuclear Information System (INIS)

    Bramlitt, E.T.; Johnson, N.R.

    1995-01-01

    Thermo Nuclear Services (TNS) has developed a mower detector as an inexpensive and fast means for deciding potential value of soil sorting for cleanup. It is a shielded detector box on wheels pushed over the ground (as a person mows grass) at 30 ft/min with gamma-ray counts recorded every 0.25 sec. It mirror images detection by the TNS transportable sorter system which conveys soil at 30 ft/min and toggles a gate to send soil on separate paths based on counts. The mower detector shows if contamination is variable and suitable for sorting, and by unique calibration sources, it indicates detection sensitivity. The mower detector has been used to characterize some soil at Department of Energy sites in New Jersey and South Carolina

  7. Sorting processes with energy-constrained comparisons*

    Science.gov (United States)

    Geissmann, Barbara; Penna, Paolo

    2018-05-01

    We study very simple sorting algorithms based on a probabilistic comparator model. In this model, errors in comparing two elements are due to (1) the energy or effort put in the comparison and (2) the difference between the compared elements. Such algorithms repeatedly compare and swap pairs of randomly chosen elements, and they correspond to natural Markovian processes. The study of these Markov chains reveals an interesting phenomenon. Namely, in several cases, the algorithm that repeatedly compares only adjacent elements is better than the one making arbitrary comparisons: in the long-run, the former algorithm produces sequences that are "better sorted". The analysis of the underlying Markov chain poses interesting questions as the latter algorithm yields a nonreversible chain, and therefore its stationary distribution seems difficult to calculate explicitly. We nevertheless provide bounds on the stationary distributions and on the mixing time of these processes in several restrictions.

  8. Microtechnology for cell manipulation and sorting

    CERN Document Server

    Tseng, Peter; Carlo, Dino

    2017-01-01

    This book delves into the recent developments in the microscale and microfluidic technologies that allow manipulation at the single and cell aggregate level. Expert authors review the dominant mechanisms that manipulate and sort biological structures, making this a state-of-the-art overview of conventional cell sorting techniques, the principles of microfluidics, and of microfluidic devices. All chapters highlight the benefits and drawbacks of each technique they discuss, which include magnetic, electrical, optical, acoustic, gravity/sedimentation, inertial, deformability, and aqueous two-phase systems as the dominant mechanisms utilized by microfluidic devices to handle biological samples. Each chapter explains the physics of the mechanism at work, and reviews common geometries and devices to help readers decide the type of style of device required for various applications. This book is appropriate for graduate-level biomedical engineering and analytical chemistry students, as well as engineers and scientist...

  9. A Novel and Simple Spike Sorting Implementation.

    Science.gov (United States)

    Petrantonakis, Panagiotis C; Poirazi, Panayiota

    2017-04-01

    Monitoring the activity of multiple, individual neurons that fire spikes in the vicinity of an electrode, namely perform a Spike Sorting (SS) procedure, comprises one of the most important tools for contemporary neuroscience in order to reverse-engineer the brain. As recording electrodes' technology rabidly evolves by integrating thousands of electrodes in a confined spatial setting, the algorithms that are used to monitor individual neurons from recorded signals have to become even more reliable and computationally efficient. In this work, we propose a novel framework of the SS approach in which a single-step processing of the raw (unfiltered) extracellular signal is sufficient for both the detection and sorting of the activity of individual neurons. Despite its simplicity, the proposed approach exhibits comparable performance with state-of-the-art approaches, especially for spike detection in noisy signals, and paves the way for a new family of SS algorithms with the potential for multi-recording, fast, on-chip implementations.

  10. Colour based sorting station with Matlab simulation

    Directory of Open Access Journals (Sweden)

    Constantin Victor

    2017-01-01

    Full Text Available The paper presents the design process and manufacturing elements of a colour-based sorting station. The system is comprised of a gravitational storage, which also contains the colour sensor. Parts are extracted using a linear pneumatic motor and are fed onto an electrically driven conveyor belt. Extraction of the parts is done at 4 points, using two pneumatic motors and a geared DC motor, while the 4th position is at the end of the belt. The mechanical parts of the system are manufactured using 3D printer technology, allowing for easy modification and adaption to the geometry of different parts. The paper shows all of the stages needed to design, optimize, test and implement the proposed solution. System optimization was performed using a graphical Matlab interface which also allows for sorting algorithm optimization.

  11. Efficient sorting using registers and caches

    DEFF Research Database (Denmark)

    Wickremesinghe, Rajiv; Arge, Lars Allan; Chase, Jeffrey S.

    2002-01-01

    . Inadequate models lead to poor algorithmic choices and an incomplete understanding of algorithm behavior on real machines.A key step toward developing better models is to quantify the performance effects of features not reflected in the models. This paper explores the effect of memory system features...... on sorting performance. We introduce a new cache-conscious sorting algorithm, R-MERGE, which achieves better performance in practice over algorithms that are superior in the theoretical models. R-MERGE is designed to minimize memory stall cycles rather than cache misses by considering features common to many......Modern computer systems have increasingly complex memory systems. Common machine models for algorithm analysis do not reflect many of the features of these systems, e.g., large register sets, lockup-free caches, cache hierarchies, associativity, cache line fetching, and streaming behavior...

  12. A mower detector to judge soil sorting

    Energy Technology Data Exchange (ETDEWEB)

    Bramlitt, E.T.; Johnson, N.R. [Thermo Nuclear Services, Inc., Albuquerque, NM (United States)

    1995-12-31

    Thermo Nuclear Services (TNS) has developed a mower detector as an inexpensive and fast means for deciding potential value of soil sorting for cleanup. It is a shielded detector box on wheels pushed over the ground (as a person mows grass) at 30 ft/min with gamma-ray counts recorded every 0.25 sec. It mirror images detection by the TNS transportable sorter system which conveys soil at 30 ft/min and toggles a gate to send soil on separate paths based on counts. The mower detector shows if contamination is variable and suitable for sorting, and by unique calibration sources, it indicates detection sensitivity. The mower detector has been used to characterize some soil at Department of Energy sites in New Jersey and South Carolina.

  13. System for optical sorting of microscopic objects

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to a system for optical sorting of microscopic objects and corresponding method. An optical detection system (52) is capable of determining the positions of said first and/or said second objects. One or more force transfer units (200, 205, 210, 215) are placed...... in a first reservoir, the one or more force units being suitable for optical momentum transfer. An electromagnetic radiation source (42) yields a radiation beam (31, 32) capable of optically displacing the force transfer units from one position to another within the first reservoir (1R). The force transfer...... units are displaced from positions away from the first objects to positions close to the first objects, and then displacing the first objects via a contact force (300) between the first objects and the force transfer units facilitates an optical sorting of the first objects and the second objects....

  14. Efficient Sorting on the Tilera Manycore Architecture

    Energy Technology Data Exchange (ETDEWEB)

    Morari, Alessandro; Tumeo, Antonino; Villa, Oreste; Secchi, Simone; Valero, Mateo

    2012-10-24

    e present an efficient implementation of the radix sort algo- rithm for the Tilera TILEPro64 processor. The TILEPro64 is one of the first successful commercial manycore processors. It is com- posed of 64 tiles interconnected through multiple fast Networks- on-chip and features a fully coherent, shared distributed cache. The architecture has a large degree of flexibility, and allows various optimization strategies. We describe how we mapped the algorithm to this architecture. We present an in-depth analysis of the optimizations for each phase of the algorithm with respect to the processor’s sustained performance. We discuss the overall throughput reached by our radix sort implementation (up to 132 MK/s) and show that it provides comparable or better performance-per-watt with respect to state-of-the art implemen- tations on x86 processors and graphic processing units.

  15. Microstructural study of tungsten influence on Co-Cr alloys

    International Nuclear Information System (INIS)

    Karaali, A.; Mirouh, K.; Hamamda, S.; Guiraldenq, P.

    2005-01-01

    Alloying elements, such as W, Mo, Mn,..., are of a great importance in the preoxidation of dental alloys and, consequently, on the ceramic/metal bond quality. This study deals with the effect of tungsten addition on the microstructural state of Co-Cr dental alloys, before the ceramisation process. These materials were prepared by unidirectional solidification. Their characterization has been carried out, using transmission electron microscopy (TEM) and X-ray diffraction. It shows that the addition of tungsten up to 8 wt.% induces structural transformations, which are believed to be linked to the added amount of tungsten

  16. Performance pay, sorting and social motivation

    OpenAIRE

    Eriksson, Tor; Villeval, Marie Claire

    2008-01-01

    International audience; Variable pay links pay and performance but may also help firms in attracting more productive employees. Our experiment investigates the impact of performance pay on both incentives and sorting and analyzes the influence of repeated interactions between firms and employees on these effects. We show that (i) the opportunity to switch from a fixed wage to variable pay scheme increases the average effort level and its variance; (ii) high skill employees concentrate under t...

  17. A sorting network in bounded arithmetic

    Czech Academy of Sciences Publication Activity Database

    Jeřábek, Emil

    2011-01-01

    Roč. 162, č. 4 (2011), s. 341-355 ISSN 0168-0072 R&D Projects: GA AV ČR IAA1019401; GA MŠk(CZ) 1M0545 Institutional research plan: CEZ:AV0Z10190503 Keywords : bounded arithmetic * sorting network * proof complexity * monotone sequent calculus Subject RIV: BA - General Mathematics Impact factor: 0.450, year: 2011 http://www.sciencedirect.com/science/article/pii/S0168007210001272

  18. Job Sorting in African Labor Markets

    OpenAIRE

    Marcel Fafchamps; Mans Soderbom; Najy Benhassine

    2006-01-01

    Using matched employer-employee data from eleven African countries, we investigate if there is a job sorting in African labor markets. We find that much of the wage gap correlated with education is driven by selection across occupations and firms. This is consistent with educated workers being more effective at complex tasks like labor management. In all countries the education wage gap widens rapidly at high low levels of education. Most of the education wage gap at low levels of education c...

  19. Parallel integer sorting with medium and fine-scale parallelism

    Science.gov (United States)

    Dagum, Leonardo

    1993-01-01

    Two new parallel integer sorting algorithms, queue-sort and barrel-sort, are presented and analyzed in detail. These algorithms do not have optimal parallel complexity, yet they show very good performance in practice. Queue-sort designed for fine-scale parallel architectures which allow the queueing of multiple messages to the same destination. Barrel-sort is designed for medium-scale parallel architectures with a high message passing overhead. The performance results from the implementation of queue-sort on a Connection Machine CM-2 and barrel-sort on a 128 processor iPSC/860 are given. The two implementations are found to be comparable in performance but not as good as a fully vectorized bucket sort on the Cray YMP.

  20. Stochastic Model of Vesicular Sorting in Cellular Organelles

    Science.gov (United States)

    Vagne, Quentin; Sens, Pierre

    2018-02-01

    The proper sorting of membrane components by regulated exchange between cellular organelles is crucial to intracellular organization. This process relies on the budding and fusion of transport vesicles, and should be strongly influenced by stochastic fluctuations, considering the relatively small size of many organelles. We identify the perfect sorting of two membrane components initially mixed in a single compartment as a first passage process, and we show that the mean sorting time exhibits two distinct regimes as a function of the ratio of vesicle fusion to budding rates. Low ratio values lead to fast sorting but result in a broad size distribution of sorted compartments dominated by small entities. High ratio values result in two well-defined sorted compartments but sorting is exponentially slow. Our results suggest an optimal balance between vesicle budding and fusion for the rapid and efficient sorting of membrane components and highlight the importance of stochastic effects for the steady-state organization of intracellular compartments.

  1. Evaluation of dental solid waste in Hamedan

    Directory of Open Access Journals (Sweden)

    Nabizadeh R.

    2009-08-01

    Full Text Available "nBackground and Aim: Today, one of the most important environmental issues is dental solid wastes which are of great importance because of the presence of hazardous, toxic and pathogen agents. In this survey, solid waste produced in Hamedan general dental offices is evaluated. "nMaterials and Methods: In this descriptive study, from 104 general dental offices in Hamedan , 10 offices were selected in simple random way. From each offices, 3 sample at the end of successive working day (Sunday, Monday and Tuesday were analyzed. Samples were manually sorted into different 74 components and measured by means of laboratory scale. Then, measured components were classified in the basis of characteristic and hazardous potential as well as material type. "nResults: Total annual waste produced in general dental offices in Hamadan is 14662.67 Kg (9315.45>95.0% Confidence Interval>20009.88. Production percentages of infectious, domestic type, chemical and pharmaceutical and toxic wastes were 51.93, 38.16, 9.47, 0.44 respectively. Main components of produced dental waste were 14 components that consist of more than 80 percents of total dental solid waste. So, waste reduction, separation and recycling plans in the offices must be concentrated on these main components. "nConclusion: In order to dental waste proper management, it is suggested that in addition to educate dentists for waste reduction, separation and recycling in the offices, each section of dental waste(toxic,chemical and pharmaceutical, infectious and domestic type wastes separately and according to related criteria should be managed.

  2. Artifacts by dental materials on magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hong, Hyun Sook; Choi, Deuk Lin; Kim, Ki Jung; Suh, Won Hyuck

    1992-01-01

    Magnetic resonance imaging (MRI) has proved to be a valuable method for evaluation of the head and neck. Unfortunately, metallic devices associated with certain dental fillings and appliances often cause variable artifacts that can obscure normal or pathologic conditions on MR and computed tomography. In this work, we assessed the MR appearance of dental prosthetic materials in vitro and in vivo including precious alloys, nonprecions alloys, resin, amalgam and titanium alloy. For in vivo studies, these materials were placed in healthy volunteer's mouths and then images were assessed. Analysis of the appearance of shape and extent of artifact, and observed influence of these artifacts on the image interpretation at 0.2 Tesla permanent type MR scanner were valuated. Material used as temporary or permanent filling of crowns such as amalgam, precious alloy and, microfilled resin did not cause artifact on the image. The size of the artifact produced by the nonprecious alloys was influenced by the ferromagnetism of the object and the volume prosthesis, and was related to the scanning sequence. Nonprecious alloys produced minimal local signal distortion, where precious alloys, and dental resin had no effect on the MR images in vivo. These results were mainly from a low field strength MR scanner used in this study

  3. Automatic Color Sorting of Hardwood Edge-Glued Panel Parts

    Science.gov (United States)

    D. Earl Kline; Richard Conners; Qiang Lu; Philip A. Araman

    1997-01-01

    This paper describes an automatic color sorting system for red oak edge-glued panel parts. The color sorting system simultaneously examines both faces of a panel part and then determines which face has the "best" color, and sorts the part into one of a number of color classes at plant production speeds. Initial test results show that the system generated over...

  4. Categorizing Variations of Student-Implemented Sorting Algorithms

    Science.gov (United States)

    Taherkhani, Ahmad; Korhonen, Ari; Malmi, Lauri

    2012-01-01

    In this study, we examined freshmen students' sorting algorithm implementations in data structures and algorithms' course in two phases: at the beginning of the course before the students received any instruction on sorting algorithms, and after taking a lecture on sorting algorithms. The analysis revealed that many students have insufficient…

  5. Order-sorted Algebraic Specifications with Higher-order Functions

    DEFF Research Database (Denmark)

    Haxthausen, Anne Elisabeth

    1995-01-01

    This paper gives a proposal for how order-sorted algebraic specification languages can be extended with higher-order functions. The approach taken is a generalisation to the order-sorted case of an approach given by Mller, Tarlecki and Wirsing for the many-sorted case. The main idea in the proposal...

  6. Gender Sorting across K-12 Schools in the United States

    Science.gov (United States)

    Long, Mark C.; Conger, Dylan

    2013-01-01

    This article documents evidence of nonrandom gender sorting across K-12 schools in the United States. The sorting exists among coed schools and at all grade levels, and it is highest in the secondary school grades. We observe some gender sorting across school sectors and types: for instance, males are slightly underrepresented in private schools…

  7. Clareamento Dental

    OpenAIRE

    Sossai, Najara; Universidade Paranaense - UNIPAR; Verdinelli, Ellen Carla; Universidade Paranaense - UNIPAR; Bassegio, Wagner; Universidade Paranaense - UNIPAR

    2011-01-01

    O clareamento dental já é utilizado há bastante tempo na Odontologia e atualmente é um dos tratamentos odontológicos mais solicitados para obtenção de um sorriso mais estético. Classificado em clareamento caseiro e/ou de consultório, ambas as técnicas são motivo de polêmica quanto aos seus benefícios, riscos, limitações e efeito clareador, bem como sobre qual é a melhor técnica existente para a promoção de um clareamento dental eficaz e seguro. Neste contexto, o presente estudo tem por objeti...

  8. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  9. American Dental Education Association

    Science.gov (United States)

    ... Interest Groups ADEA Governance Documents and Publications ADEA Dental Faculty Code of Conduct ADEA Bylaws ADEAGies Foundation ... Benefits for Faculty ADEA Member Benefits for Allied Dental Programs ADEA Member Benefits for Dental Schools ADEA ...

  10. Dental Holography

    Science.gov (United States)

    Dirtoft, Ingegerd

    1983-12-01

    Ten years have passed since the first articles appeared in this new field. The qualities of the laser light together with the need of contactless 3-D measurements for different dental purposes seemed to be extremely promising, but still just a few scientists have used the method and mostly for laboratory studies. For some reason there has been a preponderance for orthodontic measurements. This seems to be a bit peculiar from holographic view compared with measurements for engineering purposes, which usually are made on metals. So naturally holography can become a clinical tool for measurements in the field of fixed bridges, removable partial dentures and implants. One of the problems is that the need for holography in dental research must be fulfilled in collaboration with physicists. Only a two-way communication during an entire experiment can balance both technical and odontological demands and thus give practical and clinical important results. The need for an easy way of handling the evaluation to get all required information is another problem and of course the holographic equipment must be converted to a box easy to handle for everyone. At last the position of dental holography today is going to be carefully examined together with an attempt to look into the hopefully exciting and not to utopic future for this research field.

  11. Machinability of experimental Ti-Ag alloys.

    Science.gov (United States)

    Kikuchi, Masafumi; Takahashi, Masatoshi; Okuno, Osamu

    2008-03-01

    This study investigated the machinability of experimental Ti-Ag alloys (5, 10, 20, and 30 mass% Ag) as a new dental titanium alloy candidate for CAD/CAM use. The alloys were slotted with a vertical milling machine and carbide square end mills under two cutting conditions. Machinability was evaluated through cutting force using a three-component force transducer fixed on the table of the milling machine. The horizontal cutting force of the Ti-Ag alloys tended to decrease as the concentration of silver increased. Values of the component of the horizontal cutting force perpendicular to the feed direction for Ti-20% Ag and Ti-30% Ag were more than 20% lower than those for titanium under both cutting conditions. Alloying with silver significantly improved the machinability of titanium in terms of cutting force under the present cutting conditions.

  12. Danish dental education:

    DEFF Research Database (Denmark)

    Moore, Rod

    1985-01-01

    The effects of Danish cultural traditions on dental education in Denmark are described, as well as the system's current structure and developing issues. Some Danish ideas for future exports of dental education programs and dental personnel are also discussed.......The effects of Danish cultural traditions on dental education in Denmark are described, as well as the system's current structure and developing issues. Some Danish ideas for future exports of dental education programs and dental personnel are also discussed....

  13. Cache-Aware and Cache-Oblivious Adaptive Sorting

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Fagerberg, Rolf; Moruz, Gabriel

    2005-01-01

    Two new adaptive sorting algorithms are introduced which perform an optimal number of comparisons with respect to the number of inversions in the input. The first algorithm is based on a new linear time reduction to (non-adaptive) sorting. The second algorithm is based on a new division protocol...... for the GenericSort algorithm by Estivill-Castro and Wood. From both algorithms we derive I/O-optimal cache-aware and cache-oblivious adaptive sorting algorithms. These are the first I/O-optimal adaptive sorting algorithms....

  14. Online sorting of recovered wood waste by automated XRF-technology: part II. Sorting efficiencies.

    Science.gov (United States)

    Hasan, A Rasem; Solo-Gabriele, Helena; Townsend, Timothy

    2011-04-01

    Sorting of waste wood is an important process practiced at recycling facilities in order to detect and divert contaminants from recycled wood products. Contaminants of concern include arsenic, chromium and copper found in chemically preserved wood. The objective of this research was to evaluate the sorting efficiencies of both treated and untreated parts of the wood waste stream, and metal (As, Cr and Cu) mass recoveries by the use of automated X-ray fluorescence (XRF) systems. A full-scale system was used for experimentation. This unit consisted of an XRF-detection chamber mounted on the top of a conveyor and a pneumatic slide-way diverter which sorted wood into presumed treated and presumed untreated piles. A randomized block design was used to evaluate the operational conveyance parameters of the system, including wood feed rate and conveyor belt speed. Results indicated that online sorting efficiencies of waste wood by XRF technology were high based on number and weight of pieces (70-87% and 75-92% for treated wood and 66-97% and 68-96% for untreated wood, respectively). These sorting efficiencies achieved mass recovery for metals of 81-99% for As, 75-95% for Cu and 82-99% of Cr. The incorrect sorting of wood was attributed almost equally to deficiencies in the detection and conveyance/diversion systems. Even with its deficiencies, the system was capable of producing a recyclable portion that met residential soil quality levels established for Florida, for an infeed that contained 5% of treated wood. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. YouTube, dentistry, and dental education.

    Science.gov (United States)

    Knösel, Michael; Jung, Klaus; Bleckmann, Annalen

    2011-12-01

    The objective of this study was to systematically assess the informational value, intention, source, and bias of videos related to dentistry available on the video-sharing Internet platform YouTube. YouTube (www.youtube.com) was searched for videos related to dentistry, using the system-generated sorts "by relevance" and "most viewed" and two categories (All and Education). Each of the first thirty results was rated by two assessors filling out a questionnaire for each (total: 120). The data were subjected to statistical analysis using Cohen's kappa, Pearson's correlation coefficient tau, Mann-Whitney U-tests, and a nonparametric three-way ANOVA, including an analysis of the interaction between the sorting and category effect, with an α-level of 5 percent. The scan produced 279,000 results in the category All and 5,050 in the category Education. The analysis revealed a wide variety of information about dentistry available on YouTube. The purpose of these videos includes entertainment, advertising, and education. The videos classified under Education have a higher degree of usefulness and informational value for laypersons, dental students, and dental professionals than those found in a broader search category. YouTube and similar social media websites offer new educational possibilities that are currently both underdeveloped and underestimated in terms of their potential value. Dentists and dental educators should also recognize the importance of these websites in shaping public opinion about their profession.

  16. Dental students--dental advocates.

    Science.gov (United States)

    Bensch, Brittany

    2010-01-01

    Student advocacy and involvement in the political process is built into the structure of the American Student Dental Association (ASDA), especially in its Legislative Grassroots Network and an internal communication network among students to ensure political awareness. Students are concerned with such issues as a universally accepted, non-patient-based licensure process, mid-level providers, loan availability and tax deductibility, financial support for schools, and service early in one's professional career (giving forward rather than giving back). Through collaboration with the American Dental Education Association and with many state associations, students participate in lobbying, awareness campaigns, and behind the scenes as legislative aids. Although students share the same love for the profession that animates established practitioners, they are perceived by legislators as being different. Students are involved in the legislative process because it represents their future.

  17. Ore sorting using natural gamma radiation

    International Nuclear Information System (INIS)

    Clark, G.J.; Dickson, B.L.; Gray, F.E.

    1980-01-01

    A method of sorting an ore which emits natural gamma radiation is described, comprising the steps of: (a) mining the ore, (b) placing, substantially at the mining location, the sampled or mined ore on to a moving conveyor belt, (c) measuring the natural gamma emission, water content and mass of the ore while the ore is on the conveyor belt, (d) using the gamma, water content and mass measurements to determine the ore grade, and (e) directing the ore to a location characteristic of its grade when it leaves the conveyor belt

  18. Optical cell sorting with multiple imaging modalities

    DEFF Research Database (Denmark)

    Banas, Andrew; Carrissemoux, Caro; Palima, Darwin

    2017-01-01

    healthy cells. With the richness of visual information, a lot of microscopy techniques have been developed and have been crucial in biological studies. To utilize their complementary advantages we adopt both fluorescence and brightfield imaging in our optical cell sorter. Brightfield imaging has...... the advantage of being non-invasive, thus maintaining cell viability. Fluorescence imaging, on the other hand, takes advantages of the chemical specificity of fluorescence markers and can validate machine vision results from brightfield images. Visually identified cells are sorted using optical manipulation...

  19. Magnetic susceptibility and electrical conductivity of metallic dental materials and their impact on MR imaging artifacts

    Czech Academy of Sciences Publication Activity Database

    Starčuková, Jana; Starčuk jr., Zenon; Hubálková, H.; Linetskiy, I.

    2008-01-01

    Roč. 24, č. 6 (2008), s. 715-723 ISSN 0109-5641 R&D Projects: GA MZd NR8110 Institutional research plan: CEZ:AV0Z20650511 Keywords : metallic dental materials * dental alloys * amalgams * MR imaging * magnetic susceptibility * electric conductivity * image artifact Subject RIV: FF - HEENT, Dentistry Impact factor: 2.941, year: 2008

  20. VANADIUM ALLOYS

    Science.gov (United States)

    Smith, K.F.; Van Thyne, R.J.

    1959-05-12

    This patent deals with vanadium based ternary alloys useful as fuel element jackets. According to the invention the ternary vanadium alloys, prepared in an arc furnace, contain from 2.5 to 15% by weight titanium and from 0.5 to 10% by weight niobium. Characteristics of these alloys are good thermal conductivity, low neutron capture cross section, good corrosion resistance, good welding and fabricating properties, low expansion coefficient, and high strength.

  1. Sorting waste - A question of good will

    CERN Multimedia

    TS Department - FM Group

    2006-01-01

    In order to minimise waste-sorting costs, CERN provides two types of container at the entrance of buildings: a green plastic container for paper/cardboard and a metal container for household-type waste. We regret that recently there has been a significant decrease in the extent to which these types of waste are sorted, for example green containers have been found to hold assorted waste such as cardboard boxes filled with polystyrene, bubble-wrap or even plastic bottles, yoghurt pots, etc. Checks have shown that this 'non-compliant' waste does not come from the rubbish bins emptied by the cleaners but is deposited there directly by inconsiderate users. During the months of October and November alone, for example, only 15% of the waste from the paper/cardboard containers was recycled and the remaining 85% had to be incinerated, which entails a high cost for CERN. You should note that once an item of non-compliant waste is found in a green container its contents are immediately sent as waste to be incinerated ...

  2. Efficiency at Sorting Cards in Compressed Air

    Science.gov (United States)

    Poulton, E. C.; Catton, M. J.; Carpenter, A.

    1964-01-01

    At a site where compressed air was being used in the construction of a tunnel, 34 men sorted cards twice, once at normal atmospheric pressure and once at 3½, 2½, or 2 atmospheres absolute pressure. An additional six men sorted cards twice at normal atmospheric pressure. When the task was carried out for the first time, all the groups of men performing at raised pressure were found to yield a reliably greater proportion of very slow responses than the group of men performing at normal pressure. There was reliably more variability in timing at 3½ and 2½ atmospheres absolute than at normal pressure. At 3½ atmospheres absolute the average performance was also reliably slower. When the task was carried out for the second time, exposure to 3½ atmospheres absolute pressure had no reliable effect. Thus compressed air affected performance only while the task was being learnt; it had little effect after practice. No reliable differences were found related to age, to length of experience in compressed air, or to the duration of the exposure to compressed air, which was never less than 10 minutes at 3½ atmospheres absolute pressure. PMID:14180485

  3. PACMan to Help Sort Hubble Proposals

    Science.gov (United States)

    Kohler, Susanna

    2017-04-01

    Every year, astronomers submit over a thousand proposals requesting time on the Hubble Space Telescope (HST). Currently, humans must sort through each of these proposals by hand before sending them off for review. Could this burden be shifted to computers?A Problem of VolumeAstronomer Molly Peeples gathered stats on the HST submissions sent in last week for the upcoming HST Cycle 25 (the deadline was Friday night), relative to previous years. This years proposal round broke the record, with over 1200 proposals submitted in total for Cycle 25. [Molly Peeples]Each proposal cycle for HST time attracts on the order of 1100 proposals accounting for far more HST time than is available. The proposals are therefore carefully reviewed by around 150 international members of the astronomy community during a six-month process to select those with the highest scientific merit.Ideally, each proposal will be read by reviewers that have scientific expertise relevant to the proposal topic: if a proposal requests HST time to study star formation, for instance, then the reviewers assigned to it should have research expertise in star formation.How does this matching of proposals to reviewers occur? The current method relies on self-reported categorization of the submitted proposals. This is unreliable, however; proposals are often mis-categorized by submitters due to misunderstanding or ambiguous cases.As a result, the Science Policies Group at the Space Telescope Science Institute (STScI) which oversees the review of HST proposals must go through each of the proposals by hand and re-categorize them. The proposals are then matched to reviewers with self-declared expertise in the same category.With the number of HST proposals on the rise and the expectation that the upcoming James Webb Space Telescope (JWST) will elicit even more proposals for time than Hubble scientists at STScI and NASA are now asking: could the human hours necessary for this task be spared? Could a computer program

  4. Bacterial lipoproteins; biogenesis, sorting and quality control.

    Science.gov (United States)

    Narita, Shin-Ichiro; Tokuda, Hajime

    2017-11-01

    Bacterial lipoproteins are a subset of membrane proteins localized on either leaflet of the lipid bilayer. These proteins are anchored to membranes through their N-terminal lipid moiety attached to a conserved Cys. Since the protein moiety of most lipoproteins is hydrophilic, they are expected to play various roles in a hydrophilic environment outside the cytoplasmic membrane. Gram-negative bacteria such as Escherichia coli possess an outer membrane, to which most lipoproteins are sorted. The Lol pathway plays a central role in the sorting of lipoproteins to the outer membrane after lipoprotein precursors are processed to mature forms in the cytoplasmic membrane. Most lipoproteins are anchored to the inner leaflet of the outer membrane with their protein moiety in the periplasm. However, recent studies indicated that some lipoproteins further undergo topology change in the outer membrane, and play critical roles in the biogenesis and quality control of the outer membrane. This article is part of a Special Issue entitled: Bacterial Lipids edited by Russell E. Bishop. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Dental radiography

    International Nuclear Information System (INIS)

    Shekhdar, J.

    1993-01-01

    Dental radiography must comply with the same regulations with which conventional radiography complies. Radiation doses to individual patients are low but, because of the large number of patients X-rayed, the collective dose to the population is not negligible. Care in siting and regular maintenance of the equipment will reduce doses to both staff and patients. To produce X-ray films with a good image quality using a low radiation dose requires attention to film processing; this is often a neglected area. (Author)

  6. Dental erozyon

    NARCIS (Netherlands)

    Özen, B.; Yönel, N.; Çetiner, S.

    2015-01-01

    Dental erozyon, plak içermeyen diş yüzeyleri üzerinde içsel ve dışsal asitlerin veya şelatların etkileriyle oluşan kimyasal bir aşınmadır. İçsel ve/veya dışsal kaynaklar nedensel faktörler olarak tanımlanırken tükürük ve pelikıl gibi biyolojik faktörler, yeme ve içme alışkanlıkları ve ağız hijyeni

  7. Comparison of mechanical and corrosion properties of graphene monolayer on Ti–Al–V and nanometric Nb{sub 2}O{sub 5} layer on Ti–Al–V alloy for dental implants applications

    Energy Technology Data Exchange (ETDEWEB)

    Kalisz, M., E-mail: malgorzata.kalisz@its.waw.pl [Motor Transport Institute, Jagiellońska 80, 03-301 Warsaw (Poland); Grobelny, M. [Motor Transport Institute, Jagiellońska 80, 03-301 Warsaw (Poland); Mazur, M. [Wroclaw University of Technology, Faculty of Microsystem Electronics and Photonics, Janiszewskiego 11/17, 50-372 Wroclaw (Poland); Zdrojek, M. [Faculty of Physics, Warsaw University of Technology, Koszykowa 75, 00-662 Warsaw (Poland); Wojcieszak, D. [Wroclaw University of Technology, Faculty of Microsystem Electronics and Photonics, Janiszewskiego 11/17, 50-372 Wroclaw (Poland); Świniarski, M.; Judek, J. [Faculty of Physics, Warsaw University of Technology, Koszykowa 75, 00-662 Warsaw (Poland); Kaczmarek, D. [Wroclaw University of Technology, Faculty of Microsystem Electronics and Photonics, Janiszewskiego 11/17, 50-372 Wroclaw (Poland)

    2015-08-31

    In this paper the comparative studies on structural, mechanical and corrosion properties of Nb{sub 2}O{sub 5}/Ti–Al–V and graphene/Ti–Al–V alloy systems have been investigated. We show that the hardness of pure niobium pentoxide was ca. 8.64 GPa and graphene deposited on titanium alloy surface was equal 5.63 GPa. However, the graphene monolayer has no effect on surface hardness of titanium alloy and can be easily removed from the surface. On the other hand, the sample with graphene coating has much better corrosion resistance. Our results suggest, that the use of combined layers of niobium pentoxide and graphene, in the hybrid multilayer system can greatly improve the mechanical and corrosion properties of the titanium alloy surface. Such hybrid system can be used in the future, as protection coating for Ti alloy, in biomedical application and in other applications, where Ti alloys work in an aggressive corrosive environment and in engineering applications where friction is involved. - Highlights: • Corrosion properties of Nb{sub 2}O{sub 5}/TiAlV and graphene/TiAlV systems were investigated. • Nb{sub 2}O{sub 5} thin film improves titanium alloy surface hardness from 5.64 GPa to 8.64 GPa. • Nb{sub 2}O{sub 5} thin film improves corrosion resistance of Ti{sub 6}Al{sub 4}V in aggressive environment. • i{sub corr} for graphene monolayer deposited on Ti{sub 6}Al{sub 4}V surface decreases to 0.01 μA/cm{sup 2}. • Graphene monolayer caused decrease in the electrochemical activity of the Ti surface.

  8. Vertical sorting and the morphodynamics of bed form-dominated rivers : a sorting evolution model

    NARCIS (Netherlands)

    Blom, Astrid; Ribberink, Jan S.; Parker, Gary

    2008-01-01

    Existing sediment continuity models for nonuniform sediment suffer from a number of shortcomings, as they fail to describe vertical sorting fluxes other than through net aggradation or degradation of the bed and are based on a discrete representation of the bed material interacting with the flow. We

  9. Weaker dental enamel explains dental decay.

    Science.gov (United States)

    Vieira, Alexandre R; Gibson, Carolyn W; Deeley, Kathleen; Xue, Hui; Li, Yong

    2015-01-01

    Dental caries continues to be the most prevalent bacteria-mediated non-contagious disease of humankind. Dental professionals assert the disease can be explained by poor oral hygiene and a diet rich in sugars but this does not account for caries free individuals exposed to the same risk factors. In order to test the hypothesis that amount of amelogenin during enamel development can influence caries susceptibility, we generated multiple strains of mice with varying levels of available amelogenin during dental development. Mechanical tests showed that dental enamel developed with less amelogenin is "weaker" while the dental enamel of animals over-expressing amelogenin appears to be more resistant to acid dissolution.

  10. Nonswelling alloy

    Science.gov (United States)

    Harkness, S.D.

    1975-12-23

    An aluminum alloy containing one weight percent copper has been found to be resistant to void formation and thus is useful in all nuclear applications which currently use aluminum or other aluminum alloys in reactor positions which are subjected to high neutron doses.

  11. Nonswelling alloy

    International Nuclear Information System (INIS)

    Harkness, S.D.

    1975-01-01

    An aluminum alloy containing one weight percent copper has been found to be resistant to void formation and thus is useful in all nuclear applications which currently use aluminum or other aluminum alloys in reactor positions which are subjected to high neutron doses

  12. Particle Transport and Size Sorting in Bubble Microstreaming Flow

    Science.gov (United States)

    Thameem, Raqeeb; Rallabandi, Bhargav; Wang, Cheng; Hilgenfeldt, Sascha

    2014-11-01

    Ultrasonic driving of sessile semicylindrical bubbles results in powerful steady streaming flows that are robust over a wide range of driving frequencies. In a microchannel, this flow field pattern can be fine-tuned to achieve size-sensitive sorting and trapping of particles at scales much smaller than the bubble itself; the sorting mechanism has been successfully described based on simple geometrical considerations. We investigate the sorting process in more detail, both experimentally (using new parameter variations that allow greater control over the sorting) and theoretically (incorporating the device geometry as well as the superimposed channel flow into an asymptotic theory). This results in optimized criteria for size sorting and a theoretical description that closely matches the particle behavior close to the bubble, the crucial region for size sorting.

  13. On the Directly and Subdirectly Irreducible Many-Sorted Algebras

    Directory of Open Access Journals (Sweden)

    Climent Vidal J.

    2015-03-01

    Full Text Available A theorem of single-sorted universal algebra asserts that every finite algebra can be represented as a product of a finite family of finite directly irreducible algebras. In this article, we show that the many-sorted counterpart of the above theorem is also true, but under the condition of requiring, in the definition of directly reducible many-sorted algebra, that the supports of the factors should be included in the support of the many-sorted algebra. Moreover, we show that the theorem of Birkhoff, according to which every single-sorted algebra is isomorphic to a subdirect product of subdirectly irreducible algebras, is also true in the field of many-sorted algebras.

  14. Radiometric sorting of Rio Algom uranium ore

    International Nuclear Information System (INIS)

    Cristovici, M.A.

    1983-11-01

    An ore sample of about 0.2 percent uranium from Quirke Mine was subjected to radiometric sorting by Ore Sorters Limited. Approximately 60 percent of the sample weight fell within the sortable size range: -150 + 25 mm. Rejects of low uranium content ( 2 (2 counts/in 2 ) but only 7.6 percent of the ore, by weight, was discarded. At 0.8-0.9 counts/cm 2 (5-6 counts/in 2 ) a significant amount of rejects was removed (> 25 percent) but the uranium loss was unacceptably high (7.7 percent). Continuation of the testwork to improve the results is proposed by trying to extend the sortable size range and to reduce the amount of fines during crushing

  15. Machine-vision based optofluidic cell sorting

    DEFF Research Database (Denmark)

    Glückstad, Jesper; Bañas, Andrew

    the available light and creating 2D or 3D beam distributions aimed at the positions of the detected cells. Furthermore, the beam shaping freedom provided by GPC can allow optimizations in the beam’s propagation and its interaction with the laser catapulted and sorted cells....... machine vision1. This approach is gentler, less invasive and more economical compared to conventional FACS-systems. As cells are less responsive to plastic or glass objects commonly used in the optical manipulation literature2, and since laser safety would be an issue in clinical use, we develop efficient...... approaches in utilizing lasers and light modulation devices. The Generalized Phase Contrast (GPC) method3-9 that can be used for efficiently illuminating spatial light modulators10 or creating well-defined contiguous optical traps11 is supplemented by diffractive techniques capable of integrating...

  16. Learning sorting algorithms through visualization construction

    Science.gov (United States)

    Cetin, Ibrahim; Andrews-Larson, Christine

    2016-01-01

    Recent increased interest in computational thinking poses an important question to researchers: What are the best ways to teach fundamental computing concepts to students? Visualization is suggested as one way of supporting student learning. This mixed-method study aimed to (i) examine the effect of instruction in which students constructed visualizations on students' programming achievement and students' attitudes toward computer programming, and (ii) explore how this kind of instruction supports students' learning according to their self-reported experiences in the course. The study was conducted with 58 pre-service teachers who were enrolled in their second programming class. They expect to teach information technology and computing-related courses at the primary and secondary levels. An embedded experimental model was utilized as a research design. Students in the experimental group were given instruction that required students to construct visualizations related to sorting, whereas students in the control group viewed pre-made visualizations. After the instructional intervention, eight students from each group were selected for semi-structured interviews. The results showed that the intervention based on visualization construction resulted in significantly better acquisition of sorting concepts. However, there was no significant difference between the groups with respect to students' attitudes toward computer programming. Qualitative data analysis indicated that students in the experimental group constructed necessary abstractions through their engagement in visualization construction activities. The authors of this study argue that the students' active engagement in the visualization construction activities explains only one side of students' success. The other side can be explained through the instructional approach, constructionism in this case, used to design instruction. The conclusions and implications of this study can be used by researchers and

  17. Using Design Sketch to Teach Bubble Sort in High School

    OpenAIRE

    Liu, Chih-Hao; Jiu, Yi-Wen; Chen, Jason Jen-Yen

    2009-01-01

    Bubble Sort is simple. Yet, it seems a bit difficult for high school students. This paper presents a pedagogical methodology: Using Design Sketch to visualize the concepts in Bubble Sort, and to evaluate how this approach assists students to understand the pseudo code of Bubble Sort. An experiment is conducted in Wu-Ling Senior High School with 250 students taking part. The statistical analysis of experimental results shows that, for relatively high abstraction concepts, such as iteration num...

  18. Impact of Surface Potential on Apatite Formation in Ti Alloys Subjected to Acid and Heat Treatments.

    Science.gov (United States)

    Yamaguchi, Seiji; Hashimoto, Hideki; Nakai, Ryusuke; Takadama, Hiroaki

    2017-09-24

    Titanium metal (Ti) and its alloys are widely used in orthopedic and dental fields. We have previously shown that acid and heat treatment was effective to introduce bone bonding, osteoconduction and osteoinduction on pure Ti. In the present study, acid and heat treatment with or without initial NaOH treatment was performed on typical Ti-based alloys used in orthopedic and dental fields. Dynamic movements of alloying elements were developed, which depended on the kind of treatment and type of alloy. It was found that the simple acid and heat treatment enriched/remained the alloying elements on Ti-6Al-4V, Ti-15Mo-5Zr-3Al and Ti-15Zr-4Nb-4Ta, resulting in neutral surface charges. Thus, the treated alloys did not form apatite in a simulated body fluid (SBF) within 3 days. In contrast, when the alloys were subjected to a NaOH treatment prior to an acid and heat treatment, alloying elements were selectively removed from the alloy surfaces. As a result, the treated alloys became positively charged, and formed apatite in SBF within 3 days. Thus, the treated alloys would be useful in orthopedic and dental fields since they form apatite even in a living body and bond to bone.

  19. An empirical study on SAJQ (Sorting Algorithm for Join Queries

    Directory of Open Access Journals (Sweden)

    Hassan I. Mathkour

    2010-06-01

    Full Text Available Most queries that applied on database management systems (DBMS depend heavily on the performance of the used sorting algorithm. In addition to have an efficient sorting algorithm, as a primary feature, stability of such algorithms is a major feature that is needed in performing DBMS queries. In this paper, we study a new Sorting Algorithm for Join Queries (SAJQ that has both advantages of being efficient and stable. The proposed algorithm takes the advantage of using the m-way-merge algorithm in enhancing its time complexity. SAJQ performs the sorting operation in a time complexity of O(nlogm, where n is the length of the input array and m is number of sub-arrays used in sorting. An unsorted input array of length n is arranged into m sorted sub-arrays. The m-way-merge algorithm merges the sorted m sub-arrays into the final output sorted array. The proposed algorithm keeps the stability of the keys intact. An analytical proof has been conducted to prove that, in the worst case, the proposed algorithm has a complexity of O(nlogm. Also, a set of experiments has been performed to investigate the performance of the proposed algorithm. The experimental results have shown that the proposed algorithm outperforms other Stable–Sorting algorithms that are designed for join-based queries.

  20. A many-sorted calculus based on resolution and paramodulation

    CERN Document Server

    Walther, Christoph

    1987-01-01

    A Many-Sorted Calculus Based on Resolution and Paramodulation emphasizes the utilization of advantages and concepts of many-sorted logic for resolution and paramodulation based automated theorem proving.This book considers some first-order calculus that defines how theorems from given hypotheses by pure syntactic reasoning are obtained, shifting all the semantic and implicit argumentation to the syntactic and explicit level of formal first-order reasoning. This text discusses the efficiency of many-sorted reasoning, formal preliminaries for the RP- and ?RP-calculus, and many-sorted term rewrit

  1. Evaluation of MRI artifacts caused by metallic dental implants and classification of the dental materials in use

    Czech Academy of Sciences Publication Activity Database

    Starčuk jr., Zenon; Bartušek, Karel; Hubálková, H.; Bachorec, T.; Starčuková, Jana; Krupa, P.

    2006-01-01

    Roč. 6, č. 2 (2006), s. 24-27 ISSN 1335-8871 R&D Projects: GA MZd NR8110 Institutional research plan: CEZ:AV0Z20650511 Keywords : magnetic resonance imaging * artifacts * metallic implants * dental alloys * magnetic susceptibility Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  2. Job Analysis Techniques for Restructuring Health Manpower Education and Training in the Navy Medical Department. Attachment 4. Clinic QPCB Task Sort for Clinical Physician Assistants--Dermatology, ENT, Opththalmology, Orthopedics, and Urology.

    Science.gov (United States)

    Technomics, Inc., McLean, VA.

    This publication is Attachment 4 of a set of 16 computer listed QPCB task sorts, by career level, for the entire Hospital Corps and Dental Technician fields. Statistical data are presented in tabular form for a detailed listing of job duties for clinical physician assistants. (BT)

  3. Electrical Resistance Alloys and Low-Expansion Alloys

    DEFF Research Database (Denmark)

    Kjer, Torben

    1996-01-01

    The article gives an overview of electrical resistance alloys and alloys with low thermal expansion. The electrical resistance alloys comprise resistance alloys, heating alloys and thermostat alloys. The low expansion alloys comprise alloys with very low expansion coefficients, alloys with very low...... thermoelastic coefficients and age hardenable low expansion alloys....

  4. Dental amalgam and mercury vapor release.

    Science.gov (United States)

    Osborne, J W

    1992-09-01

    Dental diseases are among the most common ailments, and dentists in the United States spend over 50% of their time in dental practice rebuilding carious, malformed, and traumatically injured teeth. It is logical, therefore, that the majority of the dental school curriculum is devoted to the diagnosis, prevention, and treatment of teeth with anomalies. Dentists have several choices of materials they can use to accomplish the task of rebuilding teeth. Besides amalgam, they have ceramic materials, resin composites, base-metal and noble casting alloys, and glass-ionomer cements to use to restore the posterior dentition. Each of these restorative materials has advantages and disadvantages, and the clinical judgment as to when a particular material should be used is given a high priority in dental education. Amalgam is the most widely used of these restorative materials, with 92% of dentists listing it as the material of choice in the posterior of the mouth (Clinical Research Associates, 1990). Dentists have been placing amalgams for over 150 years in the US. They placed 150 million last year, which represents over 75 tons of amalgam alloy. The reasons that dentists use this restorative material so frequently are its durability, ease of manipulation, and low cost. Numerous clinical studies have been conducted on the serviceability of amalgam. Most of these have been on the old, low-copper alloys, and results indicate that they last from 8 to 15 years (Bailit et al., 1979; Osborne et al., 1980; Qvist et al., 1986). In the past 20 years, vast improvements have been made in amalgams with the development of the high-copper systems.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Sediment sorting at a side channel bifurcation

    Science.gov (United States)

    van Denderen, Pepijn; Schielen, Ralph; Hulscher, Suzanne

    2017-04-01

    Side channels have been constructed to reduce the flood risk and to increase the ecological value of the river. In various Dutch side channels large aggradation in these channels occurred after construction. Measurements show that the grain size of the deposited sediment in the side channel is smaller than the grain size found on the bed of the main channel. This suggest that sorting occurs at the bifurcation of the side channel. The objective is to reproduce with a 2D morphological model the fining of the bed in the side channel and to study the effect of the sediment sorting on morphodynamic development of the side channel. We use a 2D Delft3D model with two sediment fractions. The first fraction corresponds with the grain size that can be found on the bed of the main channel and the second fraction corresponds with the grain size found in the side channel. With the numerical model we compute several side channel configurations in which we vary the length and the width of the side channel, and the curvature of the upstream channel. From these computations we can derive the equilibrium state and the time scale of the morphodynamic development of the side channel. Preliminary results show that even when a simple sediment transport relation is used, like Engelund & Hansen, more fine sediment enters the side channel than coarse sediment. This is as expected, and is probably related to the bed slope effects which are a function of the Shields parameter. It is expected that by adding a sill at the entrance of the side channel the slope effect increases. This might reduce the amount of coarse sediment which enters the side channel even more. It is unclear whether the model used is able to reproduce the effect of such a sill correctly as modelling a sill and reproducing the correct hydrodynamic and morphodynamic behaviour is not straightforward in a 2D model. Acknowledgements: This research is funded by STW, part of the Dutch Organization for Scientific Research under

  6. Orthodontic applications of a superelastic shape-memory alloy model

    International Nuclear Information System (INIS)

    Glendenning, R.W.; Enlow, R.L.

    2000-01-01

    During orthodontic treatment, dental appliances (braces) made of shape memory alloys have the potential to provide nearly uniform low level stresses to dentitions during tooth movement over a large range of tooth displacement. In this paper we model superelastic behaviour of dental appliances using the finite element method and constitutive equations developed by F. Auricchio et al. Results of the mathematical model for 3-point bending and several promising 'closing loop' designs are compared with laboratory results for the same configurations. (orig.)

  7. A Preliminary Study of MSD-First Radix-Sorting Methed

    OpenAIRE

    小田, 哲久

    1984-01-01

    Many kinds of sorting algorithms have been developed from the age of Punched Card System. Nowadays, any sorting algorithm can be called either (1) internal sorting methed or (2) external sorting method. Internal sorting method is used only when the number of records to be sorted (N) is not so large for the internal memory of the computer system. Larger memory space has become available with the aid of semiconductor technology. Therefore, it might be desired to develop a new internal sorting m...

  8. Transcriptional profiling of cells sorted by RNA abundance

    NARCIS (Netherlands)

    Klemm, Sandy; Semrau, Stefan; Wiebrands, Kay; Mooijman, Dylan; Faddah, Dina A; Jaenisch, Rudolf; van Oudenaarden, Alexander

    We have developed a quantitative technique for sorting cells on the basis of endogenous RNA abundance, with a molecular resolution of 10-20 transcripts. We demonstrate efficient and unbiased RNA extraction from transcriptionally sorted cells and report a high-fidelity transcriptome measurement of

  9. An introduction to three algorithms for sorting in situ

    NARCIS (Netherlands)

    Dijkstra, E.W.; Gasteren, van A.J.M.

    1982-01-01

    The purpose of this paper is to give a crisp introduction to three algorithms for sorting in situ, viz. insertion sort, heapsort and smoothsort. The more complicated the algorithm, the more elaborate the justification for the design decisions embodied by it. In passing we offer a style for the

  10. The PreferenSort: A Holistic Instrument for Career Counseling

    Science.gov (United States)

    Amit, Adi; Sagiv, Lilach

    2013-01-01

    We present the PreferenSort, a career counseling instrument that derives counselees' vocational interests from their preferences among occupational titles. The PreferenSort allows for a holistic decision process, while taking into account the full complexity of occupations and encouraging deliberation about one's preferences and acceptable…

  11. New age radiometric ore sorting - the elegant solution

    International Nuclear Information System (INIS)

    Gordon, H.P.; Heuer, T.

    2000-01-01

    Radiometric ore sorting technology and application are described in two parts. Part I reviews the history of radiometric sorting in the minerals industry and describes the latest developments in radiometric sorting technology. Part II describes the history, feasibility study and approach used in the application of the new technology at Rossing Uranium Limited. There has been little progress in the field of radiometric sorting since the late 1970s. This has changed with the development of a high capacity radiometric sorter designed to operate on low-grade ore in the +75mm / -300mm size fraction. This has been designed specifically for an application at Rossing. Rossing has a long history in radiometric sorting dating back to 1968 when initial tests were conducted on the Rossing prospect. Past feasibility studies concluded that radiometric sorting would not conclusively reduce the unit cost of production unless sorting was used to increase production levels. The current feasibility study shows that the application of new radiometric sorter technology makes sorting viable without increasing production, and significantly more attractive with increased production. A pilot approach to confirm sorter performance is described. (author)

  12. Magnetic fluid equipment for sorting of secondary polyolefins from waste

    NARCIS (Netherlands)

    Rem, P.C.; Di Maio, F.; Hu, B.; Houzeaux, G.; Baltes, L.; Tierean, M.

    2012-01-01

    The paper presents the researches made on the FP7 project „Magnetic Sorting and Ultrasound Sensor Technologies for Production of High Purity Secondary Polyolefins from Waste” in order to develop a magnetic fluid equipment for sorting of polypropylene (PP) and polyethylene (PE) from polymers mixed

  13. Decision trees with minimum average depth for sorting eight elements

    KAUST Repository

    AbouEisha, Hassan M.; Chikalov, Igor; Moshkov, Mikhail

    2015-01-01

    We prove that the minimum average depth of a decision tree for sorting 8 pairwise different elements is equal to 620160/8!. We show also that each decision tree for sorting 8 elements, which has minimum average depth (the number of such trees

  14. Multiple pathways for vacuolar sorting of yeast proteinase A

    DEFF Research Database (Denmark)

    Westphal, V; Marcusson, E G; Winther, Jakob R.

    1996-01-01

    The sorting of the yeast proteases proteinase A and carboxypeptidase Y to the vacuole is a saturable, receptor-mediated process. Information sufficient for vacuolar sorting of the normally secreted protein invertase has in fusion constructs previously been found to reside in the propeptide...

  15. Science and technology of kernels and TRISO coated particle sorting

    International Nuclear Information System (INIS)

    Nothnagel, G.

    2006-09-01

    The ~1mm diameter TRISO coated particles, which form the elemental units of PBMR nuclear fuel, has to be close to spherical in order to best survive damage during sphere pressing. Spherical silicon carbide layers further provide the strongest miniature pressure vessels for fission product retention. To make sure that the final product contains particles of acceptable shape, 100% of kernels and coated particles have to be sorted on a surface-ground sorting table. Broken particles, twins, irregular (odd) shapes and extreme ellipsoids have to be separated from the final kernel and coated particle batches. Proper sorting of particles is an extremely important step in quality fuel production as the final failure fraction depends sensitively on the quality of sorting. After sorting a statistically significant sample of the sorted product is analysed for sphericity, which is defined as the ratio of maximum to minimum diameter, as part of a standard QC test to ensure conformance to German specifications. In addition a burn-leach test is done on coated particles (before pressing) and fuel spheres (after pressing) to ensure adherence to failure specifications. Because of the extreme importance of particle sorting for assurance of fuel quality it is essential to have an in-depth understanding of the capabilities and limitations of particle sorting. In this report a systematic scientific rationale is developed, from fundamental principles, to provide a basis for understanding the relationship between product quality and sorting parameters. The principles and concepts, developed in this report, will be of importance when future sorting tables (or equivalents) are to be designed. A number of new concepts and methodologies are developed to assist with equivalence validation of any two sorting tables. This is aimed in particular towards quantitative assessment of equivalence between current QC tables (closely based on the original NUKEM parameters, except for the driving mechanism

  16. A Fully Automated Approach to Spike Sorting.

    Science.gov (United States)

    Chung, Jason E; Magland, Jeremy F; Barnett, Alex H; Tolosa, Vanessa M; Tooker, Angela C; Lee, Kye Y; Shah, Kedar G; Felix, Sarah H; Frank, Loren M; Greengard, Leslie F

    2017-09-13

    Understanding the detailed dynamics of neuronal networks will require the simultaneous measurement of spike trains from hundreds of neurons (or more). Currently, approaches to extracting spike times and labels from raw data are time consuming, lack standardization, and involve manual intervention, making it difficult to maintain data provenance and assess the quality of scientific results. Here, we describe an automated clustering approach and associated software package that addresses these problems and provides novel cluster quality metrics. We show that our approach has accuracy comparable to or exceeding that achieved using manual or semi-manual techniques with desktop central processing unit (CPU) runtimes faster than acquisition time for up to hundreds of electrodes. Moreover, a single choice of parameters in the algorithm is effective for a variety of electrode geometries and across multiple brain regions. This algorithm has the potential to enable reproducible and automated spike sorting of larger scale recordings than is currently possible. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Particle sorting by Paramecium cilia arrays.

    Science.gov (United States)

    Mayne, Richard; Whiting, James G H; Wheway, Gabrielle; Melhuish, Chris; Adamatzky, Andrew

    Motile cilia are cell-surface organelles whose purposes, in ciliated protists and certain ciliated metazoan epithelia, include generating fluid flow, sensing and substance uptake. Certain properties of cilia arrays, such as beating synchronisation and manipulation of external proximate particulate matter, are considered emergent, but remain incompletely characterised despite these phenomena having being the subject of extensive modelling. This study constitutes a laboratory experimental characterisation of one of the emergent properties of motile cilia: manipulation of adjacent particulates. The work demonstrates through automated videomicrographic particle tracking that interactions between microparticles and somatic cilia arrays of the ciliated model organism Paramecium caudatum constitute a form of rudimentary 'sorting'. Small particles are drawn into the organism's proximity by cilia-induced fluid currents at all times, whereas larger particles may be held immobile at a distance from the cell margin when the cell generates characteristic feeding currents in the surrounding media. These findings can contribute to the design and fabrication of biomimetic cilia, with potential applications to the study of ciliopathies. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. A Parallel Modular Biomimetic Cilia Sorting Platform

    Directory of Open Access Journals (Sweden)

    James G. H. Whiting

    2018-03-01

    Full Text Available The aquatic unicellular organism Paramecium caudatum uses cilia to swim around its environment and to graze on food particles and bacteria. Paramecia use waves of ciliary beating for locomotion, intake of food particles and sensing. There is some evidence that Paramecia pre-sort food particles by discarding larger particles, but intake the particles matching their mouth cavity. Most prior attempts to mimic cilia-based manipulation merely mimicked the overall action rather than the beating of cilia. The majority of massive-parallel actuators are controlled by a central computer; however, a distributed control would be far more true-to-life. We propose and test a distributed parallel cilia platform where each actuating unit is autonomous, yet exchanging information with its closest neighboring units. The units are arranged in a hexagonal array. Each unit is a tileable circuit board, with a microprocessor, color-based object sensor and servo-actuated biomimetic cilia actuator. Localized synchronous communication between cilia allowed for the emergence of coordinated action, moving different colored objects together. The coordinated beating action was capable of moving objects up to 4 cm/s at its highest beating frequency; however, objects were moved at a speed proportional to the beat frequency. Using the local communication, we were able to detect the shape of objects and rotating an object using edge detection was performed; however, lateral manipulation using shape information was unsuccessful.

  19. Microfluidic-chip platform for cell sorting

    Science.gov (United States)

    Malik, Sarul; Balyan, Prerna; Akhtar, J.; Agarwal, Ajay

    2016-04-01

    Cell sorting and separation are considered to be very crucial preparatory steps for numerous clinical diagnostics and therapeutics applications in cell biology research arena. Label free cell separation techniques acceptance rate has been increased to multifold by various research groups. Size based cell separation method focuses on the intrinsic properties of the cell which not only avoids clogging issues associated with mechanical and centrifugation filtration methods but also reduces the overall cost for the process. Consequentially flow based cell separation method for continuous flow has attracted the attention of millions. Due to the realization of structures close to particle size in micro dimensions, the microfluidic devices offer precise and rapid particle manipulation which ultimately leads to an extraordinary cell separation results. The proposed microfluidic device is fabricated to separate polystyrene beads of size 1 µm, 5 µm, 10 µm and 20 µm. The actual dimensions of blood corpuscles were kept in mind while deciding the particle size of polystyrene beads which are used as a model particles for study.

  20. Nanoplasmonic lenses for bacteria sorting (Presentation Recording)

    Science.gov (United States)

    Zhu, Xiangchao; Yanik, Ahmet A.

    2015-08-01

    We demonstrate that patches of two dimensional arrays of circular plasmonic nanoholes patterned on gold-titanium thin film enables subwavelength focusing of visible light in far field region. Efficient coupling of the light with the excited surface plasmon at metal dielectric interface results in strong light transmission. As a result, surface plasmon plays an important role in the far field focusing behavior of the nanohole-aperture patches device. Furthermore, the focal length of the focused beam was found to be predominantly dependent on the overall size of the patch, which is in good agreement with that calculated by Rayleigh-Sommerfield integral formula. The focused light beam can be utilized to separate bio-particles in the dynamic range from 0.1 μm to 1 μm through mainly overcoming the drag force induced by fluid flow. In our proposed model, focused light generated by our plasmonic lenses will push the larger bio-particles in size back to the source of fluid flow and allow the smaller particles to move towards the central aperture of the patch. Such a new kind of plasmonic lenses open up possibility of sorting bacterium-like particles with plasmonic nanolenses, and also represent a promising tool in the field of virology.

  1. Help the planet by sorting your waste!

    CERN Multimedia

    2012-01-01

    Paper and cardboard waste comes in various forms, from newspapers to the toughest cardboard. Every year CERN dispatches about 200 tonnes of paper and cardboard to a recycling plant, but this is still too little when you take into consideration the tonnes of paper and cardboard that are still thrown out as part of ordinary rubbish or are incorrectly sorted into other rubbish skips.   Each office is equipped with a wastepaper bin, and a paper and cardboard container is available near every building. Cardboard boxes should be folded before they are placed in the containers in order to save space. Please note: Here are some sobering statistics: - 2 to 3 tonnes of wood pulp are required to manufacture 1 tonne of paper. - Each tonne of recycled paper means that we can save approximately 15 trees and substantial amounts of the water that is needed to extract cellulose (60 litres of water per kilo of paper). - A production of 100% recycled paper represents a 90% saving in water. - 5000 kWh of e...

  2. Tradeoffs Between Branch Mispredictions and Comparisons for Sorting Algorithms

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Moruz, Gabriel

    2005-01-01

    Branch mispredictions is an important factor affecting the running time in practice. In this paper we consider tradeoffs between the number of branch mispredictions and the number of comparisons for sorting algorithms in the comparison model. We prove that a sorting algorithm using O(dnlog n......) comparisons performs Omega(nlogd n) branch mispredictions. We show that Multiway MergeSort achieves this tradeoff by adopting a multiway merger with a low number of branch mispredictions. For adaptive sorting algorithms we similarly obtain that an algorithm performing O(dn(1+log (1+Inv/n))) comparisons must...... perform Omega(nlogd (1+Inv/n)) branch mispredictions, where Inv is the number of inversions in the input. This tradeoff can be achieved by GenericSort by Estivill-Castro and Wood by adopting a multiway division protocol and a multiway merging algorithm with a low number of branch mispredictions....

  3. Queue and stack sorting algorithm optimization and performance analysis

    Science.gov (United States)

    Qian, Mingzhu; Wang, Xiaobao

    2018-04-01

    Sorting algorithm is one of the basic operation of a variety of software development, in data structures course specializes in all kinds of sort algorithm. The performance of the sorting algorithm is directly related to the efficiency of the software. A lot of excellent scientific research queue is constantly optimizing algorithm, algorithm efficiency better as far as possible, the author here further research queue combined with stacks of sorting algorithms, the algorithm is mainly used for alternating operation queue and stack storage properties, Thus avoiding the need for a large number of exchange or mobile operations in the traditional sort. Before the existing basis to continue research, improvement and optimization, the focus on the optimization of the time complexity of the proposed optimization and improvement, The experimental results show that the improved effectively, at the same time and the time complexity and space complexity of the algorithm, the stability study corresponding research. The improvement and optimization algorithm, improves the practicability.

  4. Standard practice for cell sorting in a BSL-3 facility.

    Science.gov (United States)

    Perfetto, Stephen P; Ambrozak, David R; Nguyen, Richard; Roederer, Mario; Koup, Richard A; Holmes, Kevin L

    2011-01-01

    Over the past decade, there has been a rapid growth in the number of BSL-3 and BSL-4 laboratories in the USA and an increase in demand for infectious cell sorting in BSL-3 laboratories. In 2007, the International Society for Advancement of Cytometry (ISAC) Biosafety Committee published standards for the sorting of unfixed cells and is an important resource for biosafety procedures when performing infectious cell sorting. Following a careful risk assessment, if it is determined that a cell sorter must be located within a BSL-3 laboratory, there are a variety of factors to be considered prior to the establishment of the laboratory. This chapter outlines procedures for infectious cell sorting in a BSL-3 environment to facilitate the establishment and safe operation of a BSL-3 cell sorting laboratory. Subjects covered include containment verification, remote operation, disinfection, personal protective equipment (PPE), and instrument-specific modifications for enhanced aerosol evacuation.

  5. Development of a reactor thermalhydraulic experiment databank(SORTED1)

    International Nuclear Information System (INIS)

    Bang, Young Seck; Kim, Eun Kyoung; Kim, Hho Jung; Lee, Sang Yong

    1994-01-01

    The recent trend in thermalhydraulic safety analysis of nuclear power plant shows the best-estimate and probabilistic approaches, therefore, the verification of the best-estimate code based on the applicable experiment data has been required. The present study focused on developing a simple databank, SORTED1, to be effectively used for code verification. The development of SORTED1 includes a data collection from the various sources including ENCOUNTER, which is the reactor safety data bank of U.S. Nuclear Regulatory Commission, a reorganization of collected resources suitable for requirements of SORTED1 database management system (DBMS), and a development of a simple DBMS. The SORTED1 is designed in Unix environment with graphic user interface to improve a user convenience and has a capability to provide the test related information. The currently registered data in SORTED1 cover 759 thermalhydraulic tests including LOFT, Semiscale, etc

  6. A Comparison of Card-sorting Analysis Methods

    DEFF Research Database (Denmark)

    Nawaz, Ather

    2012-01-01

    This study investigates how the choice of analysis method for card sorting studies affects the suggested information structure for websites. In the card sorting technique, a variety of methods are used to analyse the resulting data. The analysis of card sorting data helps user experience (UX......) designers to discover the patterns in how users make classifications and thus to develop an optimal, user-centred website structure. During analysis, the recurrence of patterns of classification between users influences the resulting website structure. However, the algorithm used in the analysis influences...... the recurrent patterns found and thus has consequences for the resulting website design. This paper draws an attention to the choice of card sorting analysis and techniques and shows how it impacts the results. The research focuses on how the same data for card sorting can lead to different website structures...

  7. Tanzania Dental Journal Vol. 14 No. 1, May 2007 Oral health ...

    African Journals Online (AJOL)

    user

    *Part of this work was presented at the Tanzania Dental Association, 19th Scientific and Annual General Meeting, 22nd. –24th September 2004, Golden Tulip Hotel, Dar-es-Salaam, Tanzania. ... data on oral health behavior for children and adults ... were randomly selected and among them, sorted the ... to WHO criteria (13).

  8. Elementary characterization of Ti metal alloys used in implant dentistry

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Catarina A. M. P.; Paschuk, Sergei A.; Rocha, Anna S. S.; Corrêa, Janine Nicolosi [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Deniak, Valeriy [Instituto de Pesquisa Pelé Pequeno Príncipe, Curitiba, PR (Brazil); Camargo, Liliane [Universidade Paranaense, Umuarama, PR (Brazil); Assis, J.T, E-mail: cata-montenegro@bol.com.br, E-mail: spaschuk@gmail.com, E-mail: denyak@gmail.com, E-mail: lili_camargo2@hotmail.com, E-mail: joaquim@iprj.uerj.br [Universidade do Estado do Rio de Janeiro (UERJ), Nova Friburgo, RJ (Brazil)

    2017-07-01

    The main goal of present work is analytical characterization of standard dental implants broadly used by Brazilian dentists. An ideal biological alloy for dental implants must have very high biocompatibility, which means that such material should not provoke any serious adverse tissue response. Dental implants are generally marketed as commercially pure titanium (TiCP) due to their excellent mechanical and physical properties. However, sometimes other alloys are employed and consequently it is essential to study the chemical elements present in those alloys that could bring prejudice for the health. Present work investigated TiCP metal alloys used for dental implant manufacturing and evaluated the presence of elements. For alloy characterization and identification of elements it was used EDXRF technique. This method allows to perform the qualitative and quantitative analysis of the materials using the spectra of the characteristic X-rays emitted by the elements present in the metal samples. The experimental setup was based on two X- ray tubes, Mini X model with Ag and Au targets and X-123SDD detector (AMPTEK) and a 0.5 mm Cu collimator, developed due to specific sample geometrical and topography characteristics. Obtained results showed that implant alloys are not exactly TiCP but were manufactured using Ti-Al-V alloy, which contained Fe, Ni, Cu and Zn. The presence of such metals as Al and V in all studied samples shows very clear that studied implants were not manufactured from TiCP alloy. Moreover, according to the American Society for Testing and Materials (ASTM), these elements should not be present in TiCP. (author)

  9. Electrochemical Characterization of Surface Reactions on Biomedical Titanium alloys

    OpenAIRE

    Alkhateeb, Emad Hashim

    2008-01-01

    Titanium and its alloys are successfully used as implant materials for dental, orthopedic and osteosynthesis applications. The processes that take place at the implant tissue interface are important for the acceptance and integration of the implant. This thesis is divided into two parts: the first part deals with surface modification of titanium to improve the osseointegration, and the second part studies metastable pitting of titanium and its alloys. The weakly attached layer of a bone-like ...

  10. Elementary characterization of Ti metal alloys used in implant dentistry

    International Nuclear Information System (INIS)

    Torres, Catarina A. M. P.; Paschuk, Sergei A.; Rocha, Anna S. S.; Corrêa, Janine Nicolosi; Deniak, Valeriy; Camargo, Liliane; Assis, J.T

    2017-01-01

    The main goal of present work is analytical characterization of standard dental implants broadly used by Brazilian dentists. An ideal biological alloy for dental implants must have very high biocompatibility, which means that such material should not provoke any serious adverse tissue response. Dental implants are generally marketed as commercially pure titanium (TiCP) due to their excellent mechanical and physical properties. However, sometimes other alloys are employed and consequently it is essential to study the chemical elements present in those alloys that could bring prejudice for the health. Present work investigated TiCP metal alloys used for dental implant manufacturing and evaluated the presence of elements. For alloy characterization and identification of elements it was used EDXRF technique. This method allows to perform the qualitative and quantitative analysis of the materials using the spectra of the characteristic X-rays emitted by the elements present in the metal samples. The experimental setup was based on two X- ray tubes, Mini X model with Ag and Au targets and X-123SDD detector (AMPTEK) and a 0.5 mm Cu collimator, developed due to specific sample geometrical and topography characteristics. Obtained results showed that implant alloys are not exactly TiCP but were manufactured using Ti-Al-V alloy, which contained Fe, Ni, Cu and Zn. The presence of such metals as Al and V in all studied samples shows very clear that studied implants were not manufactured from TiCP alloy. Moreover, according to the American Society for Testing and Materials (ASTM), these elements should not be present in TiCP. (author)

  11. Dental Sealants Prevent Cavities

    Science.gov (United States)

    ... Digital Press Kit Read the MMWR Science Clips Dental Sealants Prevent Cavities Effective protection for children Language: ... more use of sealants and reimbursement of services. Dental care providers can Apply sealants to children at ...

  12. Dental Care in Scleroderma

    Science.gov (United States)

    Dental Care in Scleroderma People living with scleroderma face unique challenges while trying to maintain their oral ... They are more likely to be affected by dental conditions such as small mouth, dry mouth, jaw ...

  13. American Dental Association

    Science.gov (United States)

    ... CE providers and find CE courses. Commission on Dental Accreditation Explore CODA's role and find accredited schools and programs Joint Commission on National Dental Examinations Learn about the examinations used in licensing ...

  14. Diabetes: Dental Tips

    Science.gov (United States)

    Diabetes: Dental Tips For more copies contact: National Institute of Dental and Craniofacial Research National Oral Health Information Clearinghouse ... damage the gum and bone that hold your teeth in place and may lead to painful chewing ...

  15. American Dental Hygienists' Association

    Science.gov (United States)

    ... Now Autumn Giving: ‘Fall’ into the Future of Dental Hygiene Support the Institute for Oral Health! Give ... best for your patients! Learn More Sidebar Menu Dental Hygiene Programs Continuing Education Career Center Annual Conference ...

  16. Dental Effluent Guidelines

    Science.gov (United States)

    Overview and documents for Dental Office Category regulation (40 CFR Part 441); comprising pretreatment standards for discharges of dental amalgam pollutants, including mercury, into publicly owned treatment works (POTWs).

  17. Dental Encounter System (DES)

    Data.gov (United States)

    Department of Veterans Affairs — Dental Encounter System (DES) is an automated health care application designed to capture critical data about the operations of VA Dental Services. Information on...

  18. Dental Caries (Tooth Decay)

    Science.gov (United States)

    ... Materials Contact Us Home Research Data & Statistics Dental Caries (Tooth Decay) Dental caries (tooth decay) remains the most prevalent chronic disease ... adults, even though it is largely preventable. Although caries has significantly decreased for most Americans over the ...

  19. Dental Caries (Tooth Decay)

    Science.gov (United States)

    ... Contact Us Home Research Data & Statistics Share Dental Caries (Tooth Decay) Dental caries (tooth decay) remains the most prevalent chronic disease ... adults, even though it is largely preventable. Although caries has significantly decreased for most Americans over the ...

  20. CellSort: a support vector machine tool for optimizing fluorescence-activated cell sorting and reducing experimental effort.

    Science.gov (United States)

    Yu, Jessica S; Pertusi, Dante A; Adeniran, Adebola V; Tyo, Keith E J

    2017-03-15

    High throughput screening by fluorescence activated cell sorting (FACS) is a common task in protein engineering and directed evolution. It can also be a rate-limiting step if high false positive or negative rates necessitate multiple rounds of enrichment. Current FACS software requires the user to define sorting gates by intuition and is practically limited to two dimensions. In cases when multiple rounds of enrichment are required, the software cannot forecast the enrichment effort required. We have developed CellSort, a support vector machine (SVM) algorithm that identifies optimal sorting gates based on machine learning using positive and negative control populations. CellSort can take advantage of more than two dimensions to enhance the ability to distinguish between populations. We also present a Bayesian approach to predict the number of sorting rounds required to enrich a population from a given library size. This Bayesian approach allowed us to determine strategies for biasing the sorting gates in order to reduce the required number of enrichment rounds. This algorithm should be generally useful for improve sorting outcomes and reducing effort when using FACS. Source code available at http://tyolab.northwestern.edu/tools/ . k-tyo@northwestern.edu. Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  1. Corrosion Behavior of Ti-13Nb-13Zr and Ti-6Al-4V Alloys for Biomaterial Application

    Energy Technology Data Exchange (ETDEWEB)

    Saji, Viswanathan S.; Jeong, Yong Hoon; Choe, Han Cheol [Chosun University, Gwangju (Korea, Republic of); Yu, Jin Woo [Shingyeong University, Hwaseong (Korea, Republic of)

    2010-02-15

    Ti-13Nb-13Zr (TNZ) alloy has attracted considerable research attention in the last decade as a suitable substitute for the commercially used Ti-6Al-4V (TAV) alloy for orthopedic and dental implant applications. Hence, in the present work, a comparative evaluation has been performed on the electrochemical corrosion behavior of TNZ and TAV alloys in 0.9 wt.% NaCl solution. The result of the study showed that both the alloys had similar electrochemical behavior. The corrosion resistance of TAV alloy is found to be marginally superior to that of TNZ alloy.

  2. Corrosion Behavior of Ti-13Nb-13Zr and Ti-6Al-4V Alloys for Biomaterial Application

    International Nuclear Information System (INIS)

    Saji, Viswanathan S.; Jeong, Yong Hoon; Choe, Han Cheol; Yu, Jin Woo

    2010-01-01

    Ti-13Nb-13Zr (TNZ) alloy has attracted considerable research attention in the last decade as a suitable substitute for the commercially used Ti-6Al-4V (TAV) alloy for orthopedic and dental implant applications. Hence, in the present work, a comparative evaluation has been performed on the electrochemical corrosion behavior of TNZ and TAV alloys in 0.9 wt.% NaCl solution. The result of the study showed that both the alloys had similar electrochemical behavior. The corrosion resistance of TAV alloy is found to be marginally superior to that of TNZ alloy

  3. DENTAL SCHOOL PLANNING.

    Science.gov (United States)

    GALAGAN, DONALD J.

    THIS DISCUSSION PRESENTS A COMPLETE PICTURE OF THE CURRENT STATE OF DENTAL EDUCATION WITH SUGGESTIONS FOR MEETING THE DEMANDS FOR DENTAL STAFF AND FACILITIES. THE AREAS INVESTIGATED ARE (1) OBJECTIVES IN DENTAL EDUCATION--COURSES, TEACHING MODES, INNOVATIONS IN CURRICULUM, COORDINATION OF BASIC AND CLINICAL INSTRUCTION, (2) FACILITY…

  4. Stress Among Dental Students

    NARCIS (Netherlands)

    A.M. Alzahem (Abdullah)

    2015-01-01

    markdownabstractAbstract Dental students are facing many stressors in dental education, causing many negative outcomes. The most common are the exams and the clinical requirements. We suggest exposing the dental students to patient care as early as possible in their curriculum. This can help to

  5. Marketing Dental Services | Tuominen | Tanzania Dental Journal

    African Journals Online (AJOL)

    Tanzania Dental Journal. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 9, No 1 (2000) >. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register. Marketing Dental Services. R Tuominen. Abstract. No Abstract.

  6. Dental Radiographs Ordered by Dental Professionals: an ...

    African Journals Online (AJOL)

    Conclusions: Even in resource limited settings dental caries is still the regular indication for taking dental radiographs, and periapical views are the most frequent type of radiograph ordered. Maxillary central incisors and mandibular molars were types of teeth commonly x-rayed mainly due to the aesthetic importance of the ...

  7. A Simple Deep Learning Method for Neuronal Spike Sorting

    Science.gov (United States)

    Yang, Kai; Wu, Haifeng; Zeng, Yu

    2017-10-01

    Spike sorting is one of key technique to understand brain activity. With the development of modern electrophysiology technology, some recent multi-electrode technologies have been able to record the activity of thousands of neuronal spikes simultaneously. The spike sorting in this case will increase the computational complexity of conventional sorting algorithms. In this paper, we will focus spike sorting on how to reduce the complexity, and introduce a deep learning algorithm, principal component analysis network (PCANet) to spike sorting. The introduced method starts from a conventional model and establish a Toeplitz matrix. Through the column vectors in the matrix, we trains a PCANet, where some eigenvalue vectors of spikes could be extracted. Finally, support vector machine (SVM) is used to sort spikes. In experiments, we choose two groups of simulated data from public databases availably and compare this introduced method with conventional methods. The results indicate that the introduced method indeed has lower complexity with the same sorting errors as the conventional methods.

  8. The Container Problem in Bubble-Sort Graphs

    Science.gov (United States)

    Suzuki, Yasuto; Kaneko, Keiichi

    Bubble-sort graphs are variants of Cayley graphs. A bubble-sort graph is suitable as a topology for massively parallel systems because of its simple and regular structure. Therefore, in this study, we focus on n-bubble-sort graphs and propose an algorithm to obtain n-1 disjoint paths between two arbitrary nodes in time bounded by a polynomial in n, the degree of the graph plus one. We estimate the time complexity of the algorithm and the sum of the path lengths after proving the correctness of the algorithm. In addition, we report the results of computer experiments evaluating the average performance of the algorithm.

  9. Automorphism group of the modified bubble-sort graph

    OpenAIRE

    Ganesan, Ashwin

    2014-01-01

    The modified bubble-sort graph of dimension $n$ is the Cayley graph of $S_n$ generated by $n$ cyclically adjacent transpositions. In the present paper, it is shown that the automorphism group of the modified bubble sort graph of dimension $n$ is $S_n \\times D_{2n}$, for all $n \\ge 5$. Thus, a complete structural description of the automorphism group of the modified bubble-sort graph is obtained. A similar direct product decomposition is seen to hold for arbitrary normal Cayley graphs generate...

  10. Design and analysis on sorting blade for automated size-based sorting device

    Science.gov (United States)

    Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Samsudin, Yasser Suhaimi; Daud, Mohd Hisam

    2017-09-01

    Nowadays rubbish separating or recycling is a main problem of nation, where peoples dumped their rubbish into dumpsite without caring the value of the rubbish if it can be recycled and reused. Thus the author proposed an automated segregating device, purposely to teach people to separate their rubbish and value the rubbish that can be reused. The automated size-based mechanical segregating device provides significant improvements in terms of efficiency and consistency in this segregating process. This device is designed to make recycling easier, user friendly, in the hope that more people will take responsibility if it is less of an expense of time and effort. This paper discussed about redesign a blade for the sorting device which is to develop an efficient automated mechanical sorting device for the similar material but in different size. The machine is able to identify the size of waste and it depends to the coil inside the container to separate it out. The detail design and methodology is described in detail in this paper.

  11. A real time sorting algorithm to time sort any deterministic time disordered data stream

    Science.gov (United States)

    Saini, J.; Mandal, S.; Chakrabarti, A.; Chattopadhyay, S.

    2017-12-01

    In new generation high intensity high energy physics experiments, millions of free streaming high rate data sources are to be readout. Free streaming data with associated time-stamp can only be controlled by thresholds as there is no trigger information available for the readout. Therefore, these readouts are prone to collect large amount of noise and unwanted data. For this reason, these experiments can have output data rate of several orders of magnitude higher than the useful signal data rate. It is therefore necessary to perform online processing of the data to extract useful information from the full data set. Without trigger information, pre-processing on the free streaming data can only be done with time based correlation among the data set. Multiple data sources have different path delays and bandwidth utilizations and therefore the unsorted merged data requires significant computational efforts for real time manifestation of sorting before analysis. Present work reports a new high speed scalable data stream sorting algorithm with its architectural design, verified through Field programmable Gate Array (FPGA) based hardware simulation. Realistic time based simulated data likely to be collected in an high energy physics experiment have been used to study the performance of the algorithm. The proposed algorithm uses parallel read-write blocks with added memory management and zero suppression features to make it efficient for high rate data-streams. This algorithm is best suited for online data streams with deterministic time disorder/unsorting on FPGA like hardware.

  12. Superconducting alloys

    International Nuclear Information System (INIS)

    Bowers, J.E.

    1976-01-01

    Reference is made to superconductors having high critical currents. The superconductor described comprises an alloy consisting of a matrix of a Type II superconductor which is a homogeneous mixture of 50 to 95 at.% Pb and 5 to 40 at.%Bi and/or 10 to 50 at.%In. Dispersed in the matrix is a material to provide pinning centres comprising from 0.01% to 20% by volume of the alloy; this material is a stable discontinuous phase of discrete crystalline particles of Cu, Mn, Te, Se, Ni, Ca, Cr, Ce, Ge or La, either in the form of the element or a compound with a component of the matrix. These particles should have an average diameter of not more than 2μ. A method for making this alloy is described. (U.K.)

  13. Dental education in Peru.

    Science.gov (United States)

    Komabayashi, Takashi; Sato, Manuel; Rodiguez, Lyly; Sato, Doris; Bird, William F

    2008-09-01

    This paper provides information about Peru's dental history and dental school system, including the curriculum and dental licensure. With the increase in the number of dental schools in Peru, the number of dentists is also increasing. Until 1965, Peru had only three dental schools; currently, there are 14. Four of these dental schools are public, and ten are private. A five- or six-year dental program leads to the B.D.S. degree. After successful completion of a thesis defense or competency examination, the D.D.S. degree is awarded. The D.D.S. is mandatory for practicing dentistry in Peru. Currently, there are approximately 14,000 active dentists, with a dentist-patient ratio of approximately 1:2,000.

  14. Description and Documentation of the Dental School Dental Delivery System.

    Science.gov (United States)

    Chase, Rosen and Wallace, Inc., Alexandria, VA.

    A study was undertaken to describe and document the dental school dental delivery system using an integrated systems approach. In late 1976 and early 1977, a team of systems analysts and dental consultants visited three dental schools to observe the delivery of dental services and patient flow and to interview administrative staff and faculty.…

  15. Natural Selection Is a Sorting Process: What Does that Mean?

    Science.gov (United States)

    Price, Rebecca M.

    2013-01-01

    To learn why natural selection acts only on existing variation, students categorize processes as either creative or sorting. This activity helps students confront the misconception that adaptations evolve because species need them.

  16. Acoustic bubble sorting for ultrasound contrast agent enrichment.

    Science.gov (United States)

    Segers, Tim; Versluis, Michel

    2014-05-21

    An ultrasound contrast agent (UCA) suspension contains encapsulated microbubbles with a wide size distribution, with radii ranging from 1 to 10 μm. Medical transducers typically operate at a single frequency, therefore only a small selection of bubbles will resonate to the driving ultrasound pulse. Thus, the sensitivity can be improved by narrowing down the size distribution. Here, we present a simple lab-on-a-chip method to sort the population of microbubbles on-chip using a traveling ultrasound wave. First, we explore the physical parameter space of acoustic bubble sorting using well-defined bubble sizes formed in a flow-focusing device, then we demonstrate successful acoustic sorting of a commercial UCA. This novel sorting strategy may lead to an overall improvement of the sensitivity of contrast ultrasound by more than 10 dB.

  17. Recent progress in multi-electrode spike sorting methods.

    Science.gov (United States)

    Lefebvre, Baptiste; Yger, Pierre; Marre, Olivier

    2016-11-01

    In recent years, arrays of extracellular electrodes have been developed and manufactured to record simultaneously from hundreds of electrodes packed with a high density. These recordings should allow neuroscientists to reconstruct the individual activity of the neurons spiking in the vicinity of these electrodes, with the help of signal processing algorithms. Algorithms need to solve a source separation problem, also known as spike sorting. However, these new devices challenge the classical way to do spike sorting. Here we review different methods that have been developed to sort spikes from these large-scale recordings. We describe the common properties of these algorithms, as well as their main differences. Finally, we outline the issues that remain to be solved by future spike sorting algorithms. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Sorting on STAR. [CDC computer algorithm timing comparison

    Science.gov (United States)

    Stone, H. S.

    1978-01-01

    Timing comparisons are given for three sorting algorithms written for the CDC STAR computer. One algorithm is Hoare's (1962) Quicksort, which is the fastest or nearly the fastest sorting algorithm for most computers. A second algorithm is a vector version of Quicksort that takes advantage of the STAR's vector operations. The third algorithm is an adaptation of Batcher's (1968) sorting algorithm, which makes especially good use of vector operations but has a complexity of N(log N)-squared as compared with a complexity of N log N for the Quicksort algorithms. In spite of its worse complexity, Batcher's sorting algorithm is competitive with the serial version of Quicksort for vectors up to the largest that can be treated by STAR. Vector Quicksort outperforms the other two algorithms and is generally preferred. These results indicate that unusual instruction sets can introduce biases in program execution time that counter results predicted by worst-case asymptotic complexity analysis.

  19. Unsupervised spike sorting based on discriminative subspace learning.

    Science.gov (United States)

    Keshtkaran, Mohammad Reza; Yang, Zhi

    2014-01-01

    Spike sorting is a fundamental preprocessing step for many neuroscience studies which rely on the analysis of spike trains. In this paper, we present two unsupervised spike sorting algorithms based on discriminative subspace learning. The first algorithm simultaneously learns the discriminative feature subspace and performs clustering. It uses histogram of features in the most discriminative projection to detect the number of neurons. The second algorithm performs hierarchical divisive clustering that learns a discriminative 1-dimensional subspace for clustering in each level of the hierarchy until achieving almost unimodal distribution in the subspace. The algorithms are tested on synthetic and in-vivo data, and are compared against two widely used spike sorting methods. The comparative results demonstrate that our spike sorting methods can achieve substantially higher accuracy in lower dimensional feature space, and they are highly robust to noise. Moreover, they provide significantly better cluster separability in the learned subspace than in the subspace obtained by principal component analysis or wavelet transform.

  20. In-flight Sorting of BNNTs by Aspect Ratio

    Data.gov (United States)

    National Aeronautics and Space Administration — The key technical challenges are: (a) mechanical sorting is ineffective for nanoscale product, (b) BNNTs are non-conductive and the agglomeration tendency is strong,...

  1. Using Sorting Networks for Skill Building and Reasoning

    Science.gov (United States)

    Andre, Robert; Wiest, Lynda R.

    2007-01-01

    Sorting networks, used in graph theory, have instructional value as a skill- building tool as well as an interesting exploration in discrete mathematics. Students can practice mathematics facts and develop reasoning and logic skills with this topic. (Contains 4 figures.)

  2. Sorting and quantifying orbital angular momentum of laser beams

    CSIR Research Space (South Africa)

    Schulze, C

    2013-10-01

    Full Text Available We present a novel tool for sorting the orbital angular momentum and to determine the orbital angular momentum density of laser beams, which is based on the use of correlation filters....

  3. Pneumoconiosis and exposures of dental laboratory technicians

    International Nuclear Information System (INIS)

    Rom, W.N.; Lockey, J.E.; Lee, J.S.; Kimball, A.C.; Bang, K.M.; Leaman, H.; Johns, R.E. Jr.; Perrota, D.; Gibbons, H.L.

    1984-01-01

    One hundred and seventy-eight dental laboratory technicians and 69 non-exposed controls participated in an epidemiological respiratory study. Eight technicians who had a mean of 28 years grinding nonprecious metal alloys were diagnosed as having a simple pneumoconiosis by chest radiograph. Mean values for per cent predicted FVC and FEV1 were reduced among male nonsmoker technicians compared to male nonsmoker controls; after controlling for age, there was also a reduction in spirometry with increasing work-years. An industrial hygiene survey was conducted in 13 laboratories randomly selected from 42 laboratories stratified by size and type of operation in the Salt Lake City, Utah metropolitan area. Personal exposures to beryllium and cobalt exceeded the Threshold Limit Values (TLVs) in one laboratory. Occupational exposures in dental laboratories need to be controlled to prevent beryllium-related lung disorders as well as simple pneumoconiosis

  4. Silicon Alloying On Aluminium Based Alloy Surface

    International Nuclear Information System (INIS)

    Suryanto

    2002-01-01

    Silicon alloying on surface of aluminium based alloy was carried out using electron beam. This is performed in order to enhance tribological properties of the alloy. Silicon is considered most important alloying element in aluminium alloy, particularly for tribological components. Prior to silicon alloying. aluminium substrate were painted with binder and silicon powder and dried in a furnace. Silicon alloying were carried out in a vacuum chamber. The Silicon alloyed materials were assessed using some techniques. The results show that silicon alloying formed a composite metal-non metal system in which silicon particles are dispersed in the alloyed layer. Silicon content in the alloyed layer is about 40% while in other place is only 10.5 %. The hardness of layer changes significantly. The wear properties of the alloying alloys increase. Silicon surface alloying also reduced the coefficient of friction for sliding against a hardened steel counter face, which could otherwise be higher because of the strong adhesion of aluminium to steel. The hardness of the silicon surface alloyed material dropped when it underwent a heating cycle similar to the ion coating process. Hence, silicon alloying is not a suitable choice for use as an intermediate layer for duplex treatment

  5. Solid Waste Production and Its Management in Dental Clinics in Gorgan, Northern Iran

    Directory of Open Access Journals (Sweden)

    R Nabizadeh

    2014-09-01

    Full Text Available Background: Waste produced in dental clinics has been the topic of investigations for many years. These waste materials have important health impacts and are hazardous to humans and the environment. Objective: To investigating solid waste production and its management in dental clinics in Gorgan, northern Iran. Methods: In this cross-sectional study, 45 of 143 public dental practices and 5 of 25 private dental practices were selected and studied. From each clinic, 3 samples were taken and analyzed at the end of successive working days (Tuesday and Wednesday. Samples were manually sorted into 50 components. The measured components were then classified on the basis of their characteristics, hazard potentials, and WHO classification. Results: The total annual amount of dental waste produced in public and private dental practices in Gorgan was 12 015.1 and 3135.0 kg, respectively. Production percentages of infectious, domestic, chemical and pharmaceutical, and toxic waste in public dental practices were 38.4%, 33.7%, 6.6%, and 0.6%, respectively. The percentages for private practices were 8.7%, 10.6%, 1.1%, and 0.1%, respectively. Conclusion: Dental waste management in Gorgan is inadequate; dental waste is not properly segregated, collected, and disposed, as demanded by the WHO. Employees in dentist offices must be trained in correct handling of waste products and the associated risks.

  6. Solid waste production and its management in dental clinics in Gorgan, northern Iran.

    Science.gov (United States)

    Nabizadeh, R; Faraji, H; Mohammadi, A A

    2014-10-01

    Waste produced in dental clinics has been the topic of investigations for many years. These waste materials have important health impacts and are hazardous to humans and the environment. To investigating solid waste production and its management in dental clinics in Gorgan, northern Iran. In this cross-sectional study, 45 of 143 public dental practices and 5 of 25 private dental practices were selected and studied. From each clinic, 3 samples were taken and analyzed at the end of successive working days (Tuesday and Wednesday). Samples were manually sorted into 50 components. The measured components were then classified on the basis of their characteristics, hazard potentials, and WHO classification. The total annual amount of dental waste produced in public and private dental practices in Gorgan was 12 015.1 and 3135.0 kg, respectively. Production percentages of infectious, domestic, chemical and pharmaceutical, and toxic waste in public dental practices were 38.4%, 33.7%, 6.6%, and 0.6%, respectively. The percentages for private practices were 8.7%, 10.6%, 1.1%, and 0.1%, respectively. Dental waste management in Gorgan is inadequate; dental waste is not properly segregated, collected, and disposed, as demanded by the WHO. Employees in dentist offices must be trained in correct handling of waste products and the associated risks.

  7. A Model Vision of Sorting System Application Using Robotic Manipulator

    Directory of Open Access Journals (Sweden)

    Maralo Sinaga

    2010-08-01

    Full Text Available Image processing in today’s world grabs massive attentions as it leads to possibilities of broaden application in many fields of high technology. The real challenge is how to improve existing sorting system in the Moduler Processing System (MPS laboratory which consists of four integrated stations of distribution, testing, processing and handling with a new image processing feature. Existing sorting method uses a set of inductive, capacitive and optical sensors do differentiate object color. This paper presents a mechatronics color sorting system solution with the application of image processing. Supported by OpenCV, image processing procedure senses the circular objects in an image captured in realtime by a webcam and then extracts color and position information out of it. This information is passed as a sequence of sorting commands to the manipulator (Mitsubishi Movemaster RV-M1 that does pick-and-place mechanism. Extensive testing proves that this color based object sorting system works 100% accurate under ideal condition in term of adequate illumination, circular objects’ shape and color. The circular objects tested for sorting are silver, red and black. For non-ideal condition, such as unspecified color the accuracy reduces to 80%.

  8. Tribological characteristics of dental metal biomaterials

    Directory of Open Access Journals (Sweden)

    Walczak Mariusz

    2016-12-01

    Full Text Available The paper is a report of the examination of the tribological wear characteristics of certain dental metal biomaterials. In the study, tests were undertaken on the following materials: 316L steel, NiCrMo alloy, technically pure titanium (ASTM-grade 2 and Ti6Al4V ELI alloy (ASTM-grade 5. The tribological tests were performed in artificial saliva to determine the coefficient of friction and wear factor; the traces of wear were then ascertained through SEM. The significance of variations in the wear factor, was subsequently assessed by the U Mann-Whitney test. The resistance to wear in the ball-on-disc test under in vitro conditions was observed for the tested materials in the following order: NiCrMo>316L>Ti6Al4V>Ti grade 2.

  9. A useful and non-invasive microanalysis method for dental restoration materials

    International Nuclear Information System (INIS)

    Hosoki, M.; Satsuma, T.; Nishigawa, K.; Takeuchi, H.; Asaoka, K.

    2012-01-01

    Highlights: ► This method for the microanalysis of dental alloys is beneficial for patients with allergies to dental materials. ► This metal sample is easy to mail it for inspection at specialist institutes. ► This method can be also be used in general dental clinics. - Abstract: The elemental analysis of intraoral dental restorations provides considerable information for the treatment of dental metal allergy. Elemental analyses require specific instruments and complicated procedures, so this examination is not commonly carried out in private dental clinics. We describe a novel, simple and useful micro-analytical method for dental metal restorations. Micro metal dust was obtained by polishing the surface of restorative metal material with an unused silicone point (SUPER-SNAP). The metal dust on the silicone point was then rubbed onto adhesive tape, and this tape was covered with polyethylene film. The amount of metal dust material was <20 μg. An energy dispersive X-ray fluorescence spectrometer was used to carry out the elementary analysis of the metal dust on the polyethylene film. Three types of dental metal alloy materials of known components were examined. The results of elementary analyses were compared with the specifications provided by the manufacturer. The same procedure was carried out for three dental metal restorations of an adult female volunteer in vivo. The results of elemental analyses for five alloy materials exactly matched the product specification. Three metal samples obtained from intraoral restoration were also available for elemental analyses. The distinct advantage of this method is that it enables sample extraction without an invasive effect for the restoration. The metal sample is in a polyethylene film, so it is easy to mail it for inspection at specialist institutes yet it can be also be used in general dental clinics.

  10. A useful and non-invasive microanalysis method for dental restoration materials

    Energy Technology Data Exchange (ETDEWEB)

    Hosoki, M., E-mail: hosoki@tokushima-u.ac.jp [Department of Fixed Prosthodontics, Institute of Health Biosciences, University of Tokushima Graduate School, 3-18-15 Kuramoto-cho, Tokushima 770-8504 (Japan); Satsuma, T.; Nishigawa, K.; Takeuchi, H. [General Dentistry, Tokushima University Hospital, 3-18-15 Kuramoto-cho, Tokushima 770-8504 (Japan); Asaoka, K. [Department of Biomaterials and Bioengineering, Institute of Health Biosciences, University of Tokushima Graduate School, 3-18-15 Kuramoto-cho, Tokushima 770-8504 (Japan)

    2012-12-01

    Highlights: Black-Right-Pointing-Pointer This method for the microanalysis of dental alloys is beneficial for patients with allergies to dental materials. Black-Right-Pointing-Pointer This metal sample is easy to mail it for inspection at specialist institutes. Black-Right-Pointing-Pointer This method can be also be used in general dental clinics. - Abstract: The elemental analysis of intraoral dental restorations provides considerable information for the treatment of dental metal allergy. Elemental analyses require specific instruments and complicated procedures, so this examination is not commonly carried out in private dental clinics. We describe a novel, simple and useful micro-analytical method for dental metal restorations. Micro metal dust was obtained by polishing the surface of restorative metal material with an unused silicone point (SUPER-SNAP). The metal dust on the silicone point was then rubbed onto adhesive tape, and this tape was covered with polyethylene film. The amount of metal dust material was <20 {mu}g. An energy dispersive X-ray fluorescence spectrometer was used to carry out the elementary analysis of the metal dust on the polyethylene film. Three types of dental metal alloy materials of known components were examined. The results of elementary analyses were compared with the specifications provided by the manufacturer. The same procedure was carried out for three dental metal restorations of an adult female volunteer in vivo. The results of elemental analyses for five alloy materials exactly matched the product specification. Three metal samples obtained from intraoral restoration were also available for elemental analyses. The distinct advantage of this method is that it enables sample extraction without an invasive effect for the restoration. The metal sample is in a polyethylene film, so it is easy to mail it for inspection at specialist institutes yet it can be also be used in general dental clinics.

  11. 75 FR 33169 - Dental Devices: Classification of Dental Amalgam, Reclassification of Dental Mercury, Designation...

    Science.gov (United States)

    2010-06-11

    .... FDA-2008-N-0163] (formerly Docket No. 2001N-0067) RIN 0910-AG21 Dental Devices: Classification of Dental Amalgam, Reclassification of Dental Mercury, Designation of Special Controls for Dental Amalgam... the Federal Register of August 4, 2009 (74 FR 38686) which classified dental amalgam as a class II...

  12. UCSD SORT Test (U-SORT): Examination of a newly developed organizational skills assessment tool for severely mentally ill adults.

    Science.gov (United States)

    Tiznado, Denisse; Mausbach, Brent T; Cardenas, Veronica; Jeste, Dilip V; Patterson, Thomas L

    2010-12-01

    The present investigation examined the validity of a new cognitive test intended to assess organizational skills. Participants were 180 middle-aged or older participants with a Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition diagnosis of schizophrenia or schizoaffective disorder. Participants' organizational skills were measured using our newly developed University of California, San Diego Sorting Test (U-SORT), a performance-based test of organizational ability in which subjects sort objects (e.g., battery, pens) from a "junk drawer" into "keep" versus "trash" piles. Significant correlations between U-SORT scores and theoretically similar constructs (i.e. functional capacity, cognitive functioning, and clinical symptoms) were acceptable (mean r = 0.34), and weak correlations were found between U-SORT scores and theoretically dissimilar constructs (e.g., health symptoms, social support, gender; mean r = 0.06 ). The correlation between assessment scores provides preliminary support for the U-SORT test as a brief, easily transportable, reliable, and valid measure of functioning for this population.

  13. Case based dental radiology.

    Science.gov (United States)

    Niemiec, Brook A

    2009-02-01

    Dental radiology is quickly becoming integral to the standard of care in veterinary dentistry. This is not only because it is critical for proper patient care, but also because client expectations have increased. Furthermore, providing dental radiographs as a routine service can create significant practice income. This article details numerous conditions that are indications for dental radiographs. As you will see, dental radiographs are often critical for proper diagnosis and treatment. These conditions should not be viewed as unusual; they are present within all of our practices. When you choose not to radiograph these teeth, you leave behind painful pathology. Utilizing the knowledge gained from dental radiographs will both improve patient care and increase acceptance of treatment recommendations. Consequently, this leads to increased numbers of dental procedures performed at your practice.

  14. The 'simple' general dental anaesthetic

    African Journals Online (AJOL)

    Dental anaesthesia should not be underestimated. Eddie Oosthuizen .... dental surgeon has limited training in airway management. ... primary teeth to hours for extensive dental conservation .... options after the extraction of permanent teeth ...

  15. Estudo da liga alumínio-zinco como filtração alternativa em aparelhos de raios X odontológicos Study of the aluminum-zinc alloy as an alternative means of filtration in dental X-ray devices

    Directory of Open Access Journals (Sweden)

    Claudia Fátima Silva HAITER

    2002-03-01

    Full Text Available O objetivo neste trabalho foi avaliar os efeitos da filtração alternativa da liga alumínio-zinco em aparelhos de raios X odontológicos, em relação ao espectro de energia dos feixes de raios X, a taxa de kerma no ar, o índice de contraste nas radiografias obtidas e a qualidade das imagens radiográficas. Este estudo foi realizado comparando-se o filtro convencional de alumínio com várias espessuras do filtro de liga alumínio-zinco, em diferentes porcentagens do elemento zinco na liga (2%, 3%, 4% e 5%. Foi utilizado um aparelho de raios X odontológico convencional, operando com 60 kVp e 70 kVp, e filmes radiográficos dos grupos D e E de sensibilidade. Foram realizadas radiografias de um "phantom" e de uma escala de densidade de alumínio. Os resultados mostraram que o uso dos filtros de liga Al-Zn resultou em um não-endurecimento dos feixes. A taxa de kerma no ar diminuiu em até 18,53%, sem alteração no contraste das radiografias e a qualidade das imagens teve uma boa aceitação pelos examinadores. A análise dos resultados nos levou a concluir que o filtro de liga Al-Zn 2%, com 1,99 mm de espessura, tensão de 60 kVp, quando usado com filme D, foi o que obteve melhor desempenho, reduzindo a taxa de kerma no ar sem variar o índice de contraste das radiografias, mantendo a qualidade da imagem aceitável para diagnóstico, sem contudo aumentar o tempo de exposição.The aim of this study was to evaluate the effects of alternative filtration with the aluminum-zinc alloy in dental X-ray devices, regarding the energy spectrum, dose, contrast and image quality. This study was carried out comparing the conventional aluminum filter with aluminum-zinc alloy filters of various thicknesses and with different percentages of zinc in the alloy (2, 3, 4 and 5%. A conventional X-ray device operating with 60 and 70 kVp as well as D- and E-speed films were utilized in order to obtain images of a phantom and an aluminum step wedge. The utilization

  16. Spike sorting for polytrodes: a divide and conquer approach

    Directory of Open Access Journals (Sweden)

    Nicholas V. Swindale

    2014-02-01

    Full Text Available In order to determine patterns of neural activity, spike signals recorded by extracellular electrodes have to be clustered (sorted with the aim of ensuring that each cluster represents all the spikes generated by an individual neuron. Many methods for spike sorting have been proposed but few are easily applicable to recordings from polytrodes which may have 16 or more recording sites. As with tetrodes, these are spaced sufficiently closely that signals from single neurons will usually be recorded on several adjacent sites. Although this offers a better chance of distinguishing neurons with similarly shaped spikes, sorting is difficult in such cases because of the high dimensionality of the space in which the signals must be classified. This report details a method for spike sorting based on a divide and conquer approach. Clusters are initially formed by assigning each event to the channel on which it is largest. Each channel-based cluster is then sub-divided into as many distinct clusters as possible. These are then recombined on the basis of pairwise tests into a final set of clusters. Pairwise tests are also performed to establish how distinct each cluster is from the others. A modified gradient ascent clustering (GAC algorithm is used to do the clustering. The method can sort spikes with minimal user input in times comparable to real time for recordings lasting up to 45 minutes. Our results illustrate some of the difficulties inherent in spike sorting, including changes in spike shape over time. We show that some physiologically distinct units may have very similar spike shapes. We show that RMS measures of spike shape similarity are not sensitive enough to discriminate clusters that can otherwise be separated by principal components analysis. Hence spike sorting based on least-squares matching to templates may be unreliable. Our methods should be applicable to tetrodes and scaleable to larger multi-electrode arrays (MEAs.

  17. Neuronal spike sorting based on radial basis function neural networks

    Directory of Open Access Journals (Sweden)

    Taghavi Kani M

    2011-02-01

    Full Text Available "nBackground: Studying the behavior of a society of neurons, extracting the communication mechanisms of brain with other tissues, finding treatment for some nervous system diseases and designing neuroprosthetic devices, require an algorithm to sort neuralspikes automatically. However, sorting neural spikes is a challenging task because of the low signal to noise ratio (SNR of the spikes. The main purpose of this study was to design an automatic algorithm for classifying neuronal spikes that are emitted from a specific region of the nervous system."n "nMethods: The spike sorting process usually consists of three stages: detection, feature extraction and sorting. We initially used signal statistics to detect neural spikes. Then, we chose a limited number of typical spikes as features and finally used them to train a radial basis function (RBF neural network to sort the spikes. In most spike sorting devices, these signals are not linearly discriminative. In order to solve this problem, the aforesaid RBF neural network was used."n "nResults: After the learning process, our proposed algorithm classified any arbitrary spike. The obtained results showed that even though the proposed Radial Basis Spike Sorter (RBSS reached to the same error as the previous methods, however, the computational costs were much lower compared to other algorithms. Moreover, the competitive points of the proposed algorithm were its good speed and low computational complexity."n "nConclusion: Regarding the results of this study, the proposed algorithm seems to serve the purpose of procedures that require real-time processing and spike sorting.

  18. Dental pulp stem cells

    DEFF Research Database (Denmark)

    Ashri, N. Y.; Ajlan, S. A.; Aldahmash, Abdullah M.

    2015-01-01

    scaffold, and guided through signaling molecules. Dental pulp stem cells have been used in an increasing number of studies in dental tissue engineering. Those cells show mesenchymal (stromal) stem cell-like properties including self-renewal and multilineage differentiation potentials, aside from...... an updated review on dental pulp stem cells and their applications in periodontal regeneration, in combination with different scaffolds and growth factors....

  19. Dental radiology for children

    International Nuclear Information System (INIS)

    Myers, D.R.

    1984-01-01

    The benefit for the child from the judicious use of diagnostic dental radiography is improved dental health. The risk to the child from dental diagnostic radiation exposure appears to be extremely low. Despite the low risk, the dentist must minimize the child's exposure to ionizing radiation by using sound clinical judgment to determine what radiographs are necessary and to provide children with optimal protection from ionizing radiation

  20. Dental magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hilgenfeld, Tim; Bendszus, Martin; Haehnel, Stefan

    2016-01-01

    Growing distribution and utilization of digital volume tomography (DVT) extend the spectrum of clinical dental imaging. Additional diagnostic value, however, comes along with an increasing amount of radiation. In contrast, magnetic resonance imaging is a radiation free imaging technique. Furthermore, it offers a high soft tissue contrast. Morphological and numerical dental anomalies, differentiation of periapical lesions and exclusion of complications of dental diseases are field of applications for dental MRI. In addition, detection of caries and periodontal lesions and injury of inferior alveolar nerve are promising application areas in the future.

  1. A Sort-Last Rendering System over an Optical Backplane

    Directory of Open Access Journals (Sweden)

    Yasuhiro Kirihata

    2005-06-01

    Full Text Available Sort-Last is a computer graphics technique for rendering extremely large data sets on clusters of computers. Sort-Last works by dividing the data set into even-sized chunks for parallel rendering and then composing the images to form the final result. Since sort-last rendering requires the movement of large amounts of image data among cluster nodes, the network interconnecting the nodes becomes a major bottleneck. In this paper, we describe a sort-last rendering system implemented on a cluster of computers whose nodes are connected by an all-optical switch. The rendering system introduces the notion of the Photonic Computing Engine, a computing system built dynamically by using the optical switch to create dedicated network connections among cluster nodes. The sort-last volume rendering algorithm was implemented on the Photonic Computing Engine, and its performance is evaluated. Prelimi- nary experiments show that performance is affected by the image composition time and average payload size. In an attempt to stabilize the performance of the system, we have designed a flow control mechanism that uses feedback messages to dynamically adjust the data flow rate within the computing engine.

  2. Cloning of Plasmodium falciparum by single-cell sorting.

    Science.gov (United States)

    Miao, Jun; Li, Xiaolian; Cui, Liwang

    2010-10-01

    Malaria parasite cloning is traditionally carried out mainly by using the limiting dilution method, which is laborious, imprecise, and unable to distinguish multiply-infected RBCs. In this study, we used a parasite engineered to express green fluorescent protein (GFP) to evaluate a single-cell sorting method for rapidly cloning Plasmodium falciparum. By dividing a two-dimensional scattergram from a cell sorter into 17 gates, we determined the parameters for isolating singly-infected erythrocytes and sorted them into individual cultures. Pre-gating of the engineered parasites for GFP allowed the isolation of almost 100% GFP-positive clones. Compared with the limiting dilution method, the number of parasite clones obtained by single-cell sorting was much higher. Molecular analyses showed that parasite isolates obtained by single-cell sorting were highly homogenous. This highly efficient single-cell sorting method should prove very useful for cloning both P. falciparum laboratory populations from genetic manipulation experiments and clinical samples. Copyright 2010 Elsevier Inc. All rights reserved.

  3. Sorting signed permutations by inversions in O(nlogn) time.

    Science.gov (United States)

    Swenson, Krister M; Rajan, Vaibhav; Lin, Yu; Moret, Bernard M E

    2010-03-01

    The study of genomic inversions (or reversals) has been a mainstay of computational genomics for nearly 20 years. After the initial breakthrough of Hannenhalli and Pevzner, who gave the first polynomial-time algorithm for sorting signed permutations by inversions, improved algorithms have been designed, culminating with an optimal linear-time algorithm for computing the inversion distance and a subquadratic algorithm for providing a shortest sequence of inversions--also known as sorting by inversions. Remaining open was the question of whether sorting by inversions could be done in O(nlogn) time. In this article, we present a qualified answer to this question, by providing two new sorting algorithms, a simple and fast randomized algorithm and a deterministic refinement. The deterministic algorithm runs in time O(nlogn + kn), where k is a data-dependent parameter. We provide the results of extensive experiments showing that both the average and the standard deviation for k are small constants, independent of the size of the permutation. We conclude (but do not prove) that almost all signed permutations can be sorted by inversions in O(nlogn) time.

  4. UNIFICATION OF PROCESSES OF SORTING OUT OF DESTROYED CONSTRUCTION OBJECTS

    Directory of Open Access Journals (Sweden)

    SHATOV S. V.

    2015-09-01

    Full Text Available Summary. Problem statement. Technogenic catastrophes, failures or natural calamities, result in destruction of build objects. Under the obstructions of destructions can be victims. The most widespread technogenic failure is explosions of gas. The structure of obstructions changes and depends on parameters and direction of explosion, firstly its size and location of wreckages. Sorting out of obstructions is carried out with machines and mechanisms which do not meet the requirements of these works, that predetermines of carrying out of rescue or restoration works on imperfect scheme , especially on the initial stages, and it increases terms and labour intensiveness of their conduct. Development technological solution is needed for the effective sorting out of destructions of construction objects. Purpose. Development of unification solution on the improvement of technological processes of sorting out of destructions of buildings and constructions. Conclusion. The analysis of experience of works shows on sorting out of the destroyed construction objects, show that they are carried out on imperfect scheme, which do not take into account character of destruction of objects and are based on the use of construction machines which do not meet the requirements of these processes, and lead to considerable resource losses. Developed unified scheme of sorting out of the destroyed construction objects depending on character of their destruction and possibility of line of works, and also with the use of build machines with a multipurpose equipment, provide the increase of efficiency of carrying out of rescue and construction works.

  5. Cloning of Plasmodium falciparum by single-cell sorting

    Science.gov (United States)

    Miao, Jun; Li, Xiaolian; Cui, Liwang

    2010-01-01

    Malaria parasite cloning is traditionally carried out mainly by using the limiting dilution method, which is laborious, imprecise, and unable to distinguish multiply-infected RBCs. In this study, we used a parasite engineered to express green fluorescent protein (GFP) to evaluate a single-cell sorting method for rapidly cloning Plasmodium falciparum. By dividing a two dimensional scattergram from a cell sorter into 17 gates, we determined the parameters for isolating singly-infected erythrocytes and sorted them into individual cultures. Pre-gating of the engineered parasites for GFP allowed the isolation of almost 100% GFP-positive clones. Compared with the limiting dilution method, the number of parasite clones obtained by single-cell sorting was much higher. Molecular analyses showed that parasite isolates obtained by single-cell sorting were highly homogenous. This highly efficient single-cell sorting method should prove very useful for cloning both P. falciparum laboratory populations from genetic manipulation experiments and clinical samples. PMID:20435038

  6. Coupling Bacterial Activity Measurements with Cell Sorting by Flow Cytometry.

    Science.gov (United States)

    Servais; Courties; Lebaron; Troussellier

    1999-08-01

    > Abstract A new procedure to investigate the relationship between bacterial cell size and activity at the cellular level has been developed; it is based on the coupling of radioactive labeling of bacterial cells and cell sorting by flow cytometry after SYTO 13 staining. Before sorting, bacterial cells were incubated in the presence of tritiated leucine using a procedure similar to that used for measuring bacterial production by leucine incorporation and then stained with SYTO 13. Subpopulations of bacterial cells were sorted according to their average right-angle light scatter (RALS) and fluorescence. Average RALS was shown to be significantly related to the average biovolume. Experiments were performed on samples collected at different times in a Mediterranean seawater mesocosm enriched with nitrogen and phosphorus. At four sampling times, bacteria were sorted in two subpopulations (cells smaller and larger than 0.25 µm(3)). The results indicate that, at each sampling time, the growth rate of larger cells was higher than that of smaller cells. In order to confirm this tendency, cell sorting was performed on six subpopulations differing in average biovolume during the mesocosm follow-up. A clear increase of the bacterial growth rates was observed with increasing cell size for the conditions met in this enriched mesocosm.http://link.springer-ny.com/link/service/journals/00248/bibs/38n2p180.html

  7. Sorting Real Numbers in $O(n\\sqrt{\\log n})$ Time and Linear Space

    OpenAIRE

    Han, Yijie

    2017-01-01

    We present an $O(n\\sqrt{\\log n})$ time and linear space algorithm for sorting real numbers. This breaks the long time illusion that real numbers have to be sorted by comparison sorting and take $\\Omega (n\\log n)$ time to be sorted.

  8. Corrosion Characteristics of Ti-29Nb-xHf Ternary Alloy for Biomaterials

    Energy Technology Data Exchange (ETDEWEB)

    Pak, Sun Young; Choi, Han Chul [Chosun Univ., Kwangju (Korea, Republic of)

    2015-12-15

    The Cp-Ti and Ti-6Al-4V alloys were widely used for dental materials due to their mechanical properties and good corrosion resistance. However, Cp-Ti was known as bio-inert materials, Ti-6Al-4V alloy has a problem such as high Young modulus, potential loss of the surrounding bone, and to the release of potentially toxic ions from the alloy. To overcome this problem, Ti alloys containing Nb and Hf elements have been used for biomaterials due to low toxicity and high corrosion resistance. Especially, alloying element of Nb was known as β phase stabilizer. The β phase alloy was widely used to replace currently used implant materials. The corrosion resistances of Ti-29Nb-xHf ternary alloys were dependent on Hf content in oral environment solution.

  9. Education About Dental Hygienists' Roles in Public Dental Prevention Programs: Dental and Dental Hygiene Students' and Faculty Members' and Dental Hygienists' Perspectives.

    Science.gov (United States)

    Pervez, Anushey; Kinney, Janet S; Gwozdek, Anne; Farrell, Christine M; Inglehart, Marita R

    2016-09-01

    In 2005, Public Act No. 161 (PA 161) was passed in Michigan, allowing dental hygienists to practice in approved public dental prevention programs to provide services for underserved populations while utilizing a collaborative agreement with a supervising dentist. The aims of this study were to assess how well dental and dental hygiene students and faculty members and practicing dental hygienists have been educated about PA 161, what attitudes and knowledge about the act they have, and how interested they are in additional education about it. University of Michigan dental and dental hygiene students and faculty members, students in other Michigan dental hygiene programs, and dental hygienists in the state were surveyed. Respondents (response rate) were 160 dental students (50%), 63 dental hygiene students (82%), 30 dental faculty members (26%), and 12 dental hygiene faculty members (52%) at the University of Michigan; 143 dental hygiene students in other programs (20%); and 95 members of the Michigan Dental Hygienists' Association (10%). The results showed that the dental students were less educated about PA 161 than the dental hygiene students, and the dental faculty members were less informed than the dental hygiene faculty members and dental hygienists. Responding dental hygiene faculty members and dental hygienists had more positive attitudes about PA 161 than did the students and dental faculty members. Most of the dental hygiene faculty members and dental hygienists knew a person providing services in a PA 161 program. Most dental hygiene students, faculty members, and dental hygienists wanted more education about PA 161. Overall, the better educated about the program the respondents were, the more positive their attitudes, and the more interested they were in learning more.

  10. Radioisotopes in the study of the adaptation of dental amalgam fillings

    International Nuclear Information System (INIS)

    Bermawi, A.

    1995-02-01

    Adaptation expresses the significance of the relationship between the dental filling and its cavity, and forms a special challenge for the dentist when he performs dental restorative procedures. Therefore, I have done a study on the adaptation of dental amalgam fillings and their marginal leakage using radioactive iodine (I sup 1 sup 3 sup 1) and radioactive carbon (C sup 1 sup 4) on three alloys: Viva cap-Contour-Sybraloy. Marginal leakage has been established by the use of I sup 1 sup 3 sup 1, and the leakage points located by C sup 1 sup 4, by means of radioautography. This study was carried out on: - 45 dental specimens to examine marginal leakage. - 9 dental specimens to examine the time of leakage as it reached the occlusal surface. - 6 dental specimens to examine the effect of lining the cavity walls with NO sup 3 Ag varnish on marginal leakage. - 5 dental specimens to examine the effect of form (bevel) of pulpal axial point angle on marginal leakage. - 3 dental specimens as controls. - 25 dental specimens for radioautography, and to determine leakage points. The following results were observed: - Leakage occurred around the contours of all fillings under study, and spread from their basal parts to the angle of their occlusal margin. - Quantitative increase of leakage with time. - The type of the alloy played an active role in determining the pattern of leakage. - Metallic amalgam alloys with spheroidal regular atoms showed the least leakage. - The occlusal sulci exhibited more leakage than the other parts. - Beveling the pulpal axial point angle decreased leakage. - Lining the cavity walls with NO sup 3 Ag varnish inhibited leakage. - The radioactive element, to which the specimens were exposed, was unable to infiltrated and penetrate dentinal and enamel tissues. (author). 55 refs, 52 figs., 68 tabs

  11. Radioisotopes in the study of the adaptation of dental amalgam fillings

    Energy Technology Data Exchange (ETDEWEB)

    Bermawi, A [Atomic Energy Commission, Damascus (Syrian Arab Republic). Dept. of Radiation Protection and Nuclear Safety

    1995-02-01

    Adaptation expresses the significance of the relationship between the dental filling and its cavity, and forms a special challenge for the dentist when he performs dental restorative procedures. Therefore, I have done a study on the adaptation of dental amalgam fillings and their marginal leakage using radioactive iodine (I sup 1 sup 3 sup 1) and radioactive carbon (C sup 1 sup 4) on three alloys: Viva cap-Contour-Sybraloy. Marginal leakage has been established by the use of I sup 1 sup 3 sup 1, and the leakage points located by C sup 1 sup 4, by means of radioautography. This study was carried out on: - 45 dental specimens to examine marginal leakage. - 9 dental specimens to examine the time of leakage as it reached the occlusal surface. - 6 dental specimens to examine the effect of lining the cavity walls with NO sup 3 Ag varnish on marginal leakage. - 5 dental specimens to examine the effect of form (bevel) of pulpal axial point angle on marginal leakage. - 3 dental specimens as controls. - 25 dental specimens for radioautography, and to determine leakage points. The following results were observed: - Leakage occurred around the contours of all fillings under study, and spread from their basal parts to the angle of their occlusal margin. - Quantitative increase of leakage with time. - The type of the alloy played an active role in determining the pattern of leakage. - Metallic amalgam alloys with spheroidal regular atoms showed the least leakage. - The occlusal sulci exhibited more leakage than the other parts. - Beveling the pulpal axial point angle decreased leakage. - Lining the cavity walls with NO sup 3 Ag varnish inhibited leakage. - The radioactive element, to which the specimens were exposed, was unable to infiltrated and penetrate dentinal and enamel tissues. (author). 55 refs, 52 figs., 68 tabs.

  12. Adaptive differential correspondence imaging based on sorting technique

    Directory of Open Access Journals (Sweden)

    Heng Wu

    2017-04-01

    Full Text Available We develop an adaptive differential correspondence imaging (CI method using a sorting technique. Different from the conventional CI schemes, the bucket detector signals (BDS are first processed by a differential technique, and then sorted in a descending (or ascending order. Subsequently, according to the front and last several frames of the sorted BDS, the positive and negative subsets (PNS are created by selecting the relative frames from the reference detector signals. Finally, the object image is recovered from the PNS. Besides, an adaptive method based on two-step iteration is designed to select the optimum number of frames. To verify the proposed method, a single-detector computational ghost imaging (GI setup is constructed. We experimentally and numerically compare the performance of the proposed method with different GI algorithms. The results show that our method can improve the reconstruction quality and reduce the computation cost by using fewer measurement data.

  13. Particle migration and sorting in microbubble streaming flows

    Science.gov (United States)

    Thameem, Raqeeb; Hilgenfeldt, Sascha

    2016-01-01

    Ultrasonic driving of semicylindrical microbubbles generates strong streaming flows that are robust over a wide range of driving frequencies. We show that in microchannels, these streaming flow patterns can be combined with Poiseuille flows to achieve two distinctive, highly tunable methods for size-sensitive sorting and trapping of particles much smaller than the bubble itself. This method allows higher throughput than typical passive sorting techniques, since it does not require the inclusion of device features on the order of the particle size. We propose a simple mechanism, based on channel and flow geometry, which reliably describes and predicts the sorting behavior observed in experiment. It is also shown that an asymptotic theory that incorporates the device geometry and superimposed channel flow accurately models key flow features such as peak speeds and particle trajectories, provided it is appropriately modified to account for 3D effects caused by the axial confinement of the bubble. PMID:26958103

  14. Real-World Sorting of RHIC Superconducting Magnets

    International Nuclear Information System (INIS)

    Wei, J.; Gupta, R.; Harrison, M.; Jain, A.; Peggs, S.; Thompson, P.; Trbojevic, D.; Wanderer, P.

    1999-01-01

    During the seven-year construction of the Relativistic Heavy Ion Collider (RHIC), more than 1700 superconducting dipoles, quadrupoles, sextupoles, and multi-layer correctors have been constructed and installed. These magnets have been sorted at several production stages to optimize their performance and reliability. For arc magnets, priorities have bene put first on quench performance and operational risk minimization, second on field transfer function and other first-order quantities, and finally on nonlinear field errors which were painstakingly optimized at design. For Interaction-Region (IR) magnets, sorting is applied to select the best possible combination of magnets for the low-β interaction points (IP). This paper summarizes the history of this real-world sorting process

  15. Tanzania Dental Association

    African Journals Online (AJOL)

    Committee of Tanzania Dental. Association would like to Thank. [fUfNJfNJU[[j)~ for its magnanimity towards meeting the cost of this Journal ... ceps is token out of the dental kit and the tooth is removed out of its socket. The tooth is dropped into the waste bucket. The fareceps is placed in the water basin. The socket site is ...

  16. Nigerian Dental Journal

    African Journals Online (AJOL)

    ... needs of dental practitioners in Nigeria, Africa and international community interested in the dental practice in the developing world. The NDJ is published biannually and accepts reports of original research, review articles, clinical case reports and innovations in surgical techniques related to dentistry and allied subjects ...

  17. Acute dental pain II

    DEFF Research Database (Denmark)

    Jonasson, Peter; Kirkevang, Lise-Lotte; Rosen, Annika

    2016-01-01

    Acute dental pain most often occurs in relation to inflammatory conditions in the dental pulp or in the periradicular tissues surrounding a tooth, but it is not always easy to reach a diagnose and determine what treatment to perform. The anamnesis and the clinical examination provide valuable...

  18. Long term estimates for sorting strategies of the LHC dipoles

    CERN Document Server

    Scandale, Walter; Giovannozzi, Massimo; Todesco, Ezio

    1998-01-01

    Sorting strategies are investigated in view of improving the dynamic aperture of the CERN-LHC. Local and quasi-local compensation of the random field shape imperfections are discussed and applied to simplified model of the LHC lattice. The most promising strategies are further investigated on a realistic LHC model with particular emphasis on the analysis of the robustness of the dynamic aperture improvements including long term effects. First results on the application of the recently developed extrapolation law for the prediction of the dynamic aperture to the sorting problem are presented.

  19. Sorting, Searching, and Simulation in the MapReduce Framework

    DEFF Research Database (Denmark)

    Goodrich, Michael T.; Sitchinava, Nodari; Zhang, Qin

    2011-01-01

    usefulness of our approach by designing and analyzing efficient MapReduce algorithms for fundamental sorting, searching, and simulation problems. This study is motivated by a goal of ultimately putting the MapReduce framework on an equal theoretical footing with the well-known PRAM and BSP parallel...... in parallel computational geometry for the MapReduce framework, which result in efficient MapReduce algorithms for sorting, 2- and 3-dimensional convex hulls, and fixed-dimensional linear programming. For the case when mappers and reducers have a memory/message-I/O size of M = (N), for a small constant > 0...

  20. Dynamic colloidal sorting on a magnetic bubble lattice

    Science.gov (United States)

    Tierno, Pietro; Soba, Alejandro; Johansen, Tom H.; Sagués, Francesc

    2008-11-01

    We use a uniaxial garnet film with a magnetic bubble lattice to sort paramagnetic colloidal particles with different diameters, i.e., 1.0 and 2.8μm. We apply an external magnetic field which precesses around an axis normal to the film with a frequency Ω =62.8s-1 and intensity 3120A/m bubbles while the others are transported through the array. We complement the experimental measurements with numerical simulations to explore the sorting capability for particles with different magnetic moments.

  1. Faster magnet sorting with a threshold acceptance algorithm

    International Nuclear Information System (INIS)

    Lidia, S.; Carr, R.

    1995-01-01

    We introduce here a new technique for sorting magnets to minimize the field errors in permanent magnet insertion devices. Simulated annealing has been used in this role, but we find the technique of threshold acceptance produces results of equal quality in less computer time. Threshold accepting would be of special value in designing very long insertion devices, such as long free electron lasers (FELs). Our application of threshold acceptance to magnet sorting showed that it converged to equivalently low values of the cost function, but that it converged significantly faster. We present typical cases showing time to convergence for various error tolerances, magnet numbers, and temperature schedules

  2. Two-sorted Point-Interval Temporal Logics

    DEFF Research Database (Denmark)

    Balbiani, Philippe; Goranko, Valentin; Sciavicco, Guido

    2011-01-01

    There are two natural and well-studied approaches to temporal ontology and reasoning: point-based and interval-based. Usually, interval-based temporal reasoning deals with points as particular, duration-less intervals. Here we develop explicitly two-sorted point-interval temporal logical framework...... whereby time instants (points) and time periods (intervals) are considered on a par, and the perspective can shift between them within the formal discourse. We focus on fragments involving only modal operators that correspond to the inter-sort relations between points and intervals. We analyze...

  3. Constructing Efficient Dictionaries in Close to Sorting Time

    DEFF Research Database (Denmark)

    Ruzic, Milan

    2008-01-01

    to be a particularly challenging task. We present solutions to the static dictionary problem that significantly improve the previously known upper bounds and bring them close to obvious lower bounds. Our dictionaries have a constant lookup cost and use linear space, which was known to be possible, but the worst......-case cost of construction of the structures is proportional to only loglogn times the cost of sorting the input. Our claimed performance bounds are obtained in the word RAM model and in the external memory models; only the involved sorting procedures in the algorithms need to be changed between the models....

  4. 4D CT sorting based on patient internal anatomy

    Science.gov (United States)

    Li, Ruijiang; Lewis, John H.; Cerviño, Laura I.; Jiang, Steve B.

    2009-08-01

    Respiratory motion during free-breathing computed tomography (CT) scan may cause significant errors in target definition for tumors in the thorax and upper abdomen. A four-dimensional (4D) CT technique has been widely used for treatment simulation of thoracic and abdominal cancer radiotherapy. The current 4D CT techniques require retrospective sorting of the reconstructed CT slices oversampled at the same couch position. Most sorting methods depend on external surrogates of respiratory motion recorded by extra instruments. However, respiratory signals obtained from these external surrogates may not always accurately represent the internal target motion, especially when irregular breathing patterns occur. We have proposed a new sorting method based on multiple internal anatomical features for multi-slice CT scan acquired in the cine mode. Four features are analyzed in this study, including the air content, lung area, lung density and body area. We use a measure called spatial coherence to select the optimal internal feature at each couch position and to generate the respiratory signals for 4D CT sorting. The proposed method has been evaluated for ten cancer patients (eight with thoracic cancer and two with abdominal cancer). For nine patients, the respiratory signals generated from the combined internal features are well correlated to those from external surrogates recorded by the real-time position management (RPM) system (average correlation: 0.95 ± 0.02), which is better than any individual internal measures at 95% confidence level. For these nine patients, the 4D CT images sorted by the combined internal features are almost identical to those sorted by the RPM signal. For one patient with an irregular breathing pattern, the respiratory signals given by the combined internal features do not correlate well with those from RPM (correlation: 0.68 ± 0.42). In this case, the 4D CT image sorted by our method presents fewer artifacts than that from the RPM signal. Our

  5. New designs in the reconstruction of coke-sorting systems

    Energy Technology Data Exchange (ETDEWEB)

    A.S. Larin; V.V. Demenko; V.L. Voitanik [Giprokoks, the State Institute for the Design of Coke-Industry Enterprises, Kharkov (Ukraine)

    2009-07-15

    In recent Giprokoks designs for the reconstruction of coke-sorting systems, high-productivity vibrational-inertial screens have been employed. This permits single-stage screening and reduction in capital and especially operating expenditures, without loss of coke quality. In two-stage screening, >80 mm coke (for foundry needs) is additionally separated, with significant improvement in quality of the metallurgical coke (25-80 mm). New designs for the reconstruction of coke-sorting systems employ mechanical treatment of the coke outside the furnace, which offers new scope for stabilization of coke quality and permits considerable improvement in mechanical strength and granulometric composition of the coke by mechanical crushing.

  6. Decision trees with minimum average depth for sorting eight elements

    KAUST Repository

    AbouEisha, Hassan M.

    2015-11-19

    We prove that the minimum average depth of a decision tree for sorting 8 pairwise different elements is equal to 620160/8!. We show also that each decision tree for sorting 8 elements, which has minimum average depth (the number of such trees is approximately equal to 8.548×10^326365), has also minimum depth. Both problems were considered by Knuth (1998). To obtain these results, we use tools based on extensions of dynamic programming which allow us to make sequential optimization of decision trees relative to depth and average depth, and to count the number of decision trees with minimum average depth.

  7. Generic sorting of raft lipids into secretory vesicles in yeast

    DEFF Research Database (Denmark)

    Surma, Michal A; Klose, Christian; Klemm, Robin W

    2011-01-01

    Previous work has showed that ergosterol and sphingolipids become sorted to secretory vesicles immunoisolated using a chimeric, artificial raft membrane protein as bait. In this study, we have extended this analysis to three populations of secretory vesicles isolated using natural yeast plasma...... a complete lipid overview of the yeast late secretory pathway. We could show that vesicles captured with different baits carry the same cargo and have almost identical lipid compositions; being highly enriched in ergosterol and sphingolipids. This finding indicates that lipid raft sorting is a generic...

  8. Faster magnet sorting with a threshold acceptance algorithm

    International Nuclear Information System (INIS)

    Lidia, S.

    1994-08-01

    The authors introduce here a new technique for sorting magnets to minimize the field errors in permanent magnet insertion devices. Simulated annealing has been used in this role, but they find the technique of threshold acceptance produces results of equal quality in less computer time. Threshold accepting would be of special value in designing very long insertion devices, such as long FEL's. Their application of threshold acceptance to magnet sorting showed that it converged to equivalently low values of the cost function, but that it converged significantly faster. They present typical cases showing time to convergence for various error tolerances, magnet numbers, and temperature schedules

  9. Patients' satisfaction with dental care provided by public dental ...

    African Journals Online (AJOL)

    Background: In Tanzania, patient satisfaction with dental services has received only minor attention. Objective: To assess patients' satisfaction with public dental health services in Dar es Salaam. Design: A cross-sectional study. Setting: Five public dental clinics randomly selected from a list of all the nine public dental ...

  10. Dental fluorosis and dental caries prevalence among 12 and 15 ...

    African Journals Online (AJOL)

    Background: Fluoride is a double edged sword. The assessment of dental caries and fluorosis in endemic fluoride areas will facilitate in assessing the relation between fluoride concentrations in water with dental caries, dental fluorosis simultaneously. Aim: The objective of the following study is to assess the dental caries ...

  11. Awareness of dental implants among dental patients in Nigeria ...

    African Journals Online (AJOL)

    The aim of this study was to determine the level of awareness of dental implant in Nigerian patients and their willingness to choose dental implant as a tooth replacement option. A survey was conducted among patients presenting for dental treatment in 3 teaching hospitals and private dental clinics in 3 urban cities of ...

  12. What is dental ecology?

    Science.gov (United States)

    Cuozzo, Frank P; Sauther, Michelle L

    2012-06-01

    Teeth have long been used as indicators of primate ecology. Early work focused on the links between dental morphology, diet, and behavior, with more recent years emphasizing dental wear, microstructure, development, and biogeochemistry, to understand primate ecology. Our study of Lemur catta at the Beza Mahafaly Special Reserve, Madagascar, has revealed an unusual pattern of severe tooth wear and frequent tooth loss, primarily the result of consuming a fallback food for which these primates are not dentally adapted. Interpreting these data was only possible by combining our areas of expertise (dental anatomy [FC] and primate ecology [MS]). By integrating theoretical, methodological, and applied aspects of both areas of research, we adopted the term "dental ecology"-defined as the broad study of how teeth respond to the environment. Specifically, we view dental ecology as an interpretive framework using teeth as a vehicle for understanding an organism's ecology, which builds upon earlier work, but creates a new synthesis of anatomy and ecology that is only possible with detailed knowledge of living primates. This framework includes (1) identifying patterns of dental pathology and tooth use-wear, within the context of feeding ecology, behavior, habitat variation, and anthropogenic change, (2) assessing ways in which dental development and biogeochemical signals can reflect habitat, environmental change and/or stress, and (3) how dental microstructure and macro-morphology are adapted to, and reflect feeding ecology. Here we define dental ecology, provide a short summary of the development of this perspective, and place our new work into this context. Copyright © 2012 Wiley Periodicals, Inc.

  13. Various Effects of Sandblasting of Dental Restorative Materials.

    Directory of Open Access Journals (Sweden)

    Goro Nishigawa

    Full Text Available Sandblasting particles which remain on the surfaces of dental restorations are removed prior to cementation. It is probable that adhesive strength between luting material and sandblasting particle remnants might exceed that with restorative material. If that being the case, blasting particles adhere to sandblasted material surface could be instrumental to increasing adhesive strength like underlying bonding mechanism between luting material and silanized particles of tribochemical silica coating-treated surface. We hypothesize that ultrasonic cleaning of bonding surfaces, which were pretreated with sandblasting, may affect adhesive strength of a resin luting material to dental restorative materials.We therefore observed adhesive strength of resin luting material to aluminum oxide was greater than those to zirconia ceramic and cobalt-chromium alloy beforehand. To measure the shear bond strengths of resin luting material to zirconia ceramic and cobalt-chromium alloy, forty specimens of each restorative material were prepared. Bonding surfaces were polished with silicon abrasive paper and then treated with sandblasting. For each restorative material, 40 sandblasted specimens were equally divided into two groups: ultrasonic cleaning (USC group and non-ultrasonic cleaning (NUSC group. After resin luting material was polymerized on bonding surface, shear test was performed to evaluate effect of ultrasonic cleaning of bonding surfaces pretreated with sandblasting on bond strength.For both zirconia ceramic and cobalt-chromium alloy, NUSC group showed significantly higher shear bond strength than USC group.Ultrasonic cleaning of dental restorations after sandblasting should be avoided to retain improved bonding between these materials.

  14. A useful and non-invasive microanalysis method for dental restoration materials

    Science.gov (United States)

    Hosoki, M.; Satsuma, T.; Nishigawa, K.; Takeuchi, H.; Asaoka, K.

    2012-12-01

    The elemental analysis of intraoral dental restorations provides considerable information for the treatment of dental metal allergy. Elemental analyses require specific instruments and complicated procedures, so this examination is not commonly carried out in private dental clinics. We describe a novel, simple and useful micro-analytical method for dental metal restorations. Micro metal dust was obtained by polishing the surface of restorative metal material with an unused silicone point (SUPER-SNAP). The metal dust on the silicone point was then rubbed onto adhesive tape, and this tape was covered with polyethylene film. The amount of metal dust material was film. Three types of dental metal alloy materials of known components were examined. The results of elementary analyses were compared with the specifications provided by the manufacturer. The same procedure was carried out for three dental metal restorations of an adult female volunteer in vivo. The results of elemental analyses for five alloy materials exactly matched the product specification. Three metal samples obtained from intraoral restoration were also available for elemental analyses. The distinct advantage of this method is that it enables sample extraction without an invasive effect for the restoration. The metal sample is in a polyethylene film, so it is easy to mail it for inspection at specialist institutes yet it can be also be used in general dental clinics.

  15. Porous Titanium for Dental Implant Applications

    Directory of Open Access Journals (Sweden)

    Zena J. Wally

    2015-10-01

    Full Text Available Recently, an increasing amount of research has focused on the biological and mechanical behavior of highly porous structures of metallic biomaterials, as implant materials for dental implants. Particularly, pure titanium and its alloys are typically used due to their outstanding mechanical and biological properties. However, these materials have high stiffness (Young’s modulus in comparison to that of the host bone, which necessitates careful implant design to ensure appropriate distribution of stresses to the adjoining bone, to avoid stress-shielding or overloading, both of which lead to bone resorption. Additionally, many coating and roughening techniques are used to improve cell and bone-bonding to the implant surface. To date, several studies have revealed that porous geometry may be a promising alternative to bulk structures for dental implant applications. This review aims to summarize the evidence in the literature for the importance of porosity in the integration of dental implants with bone tissue and the different fabrication methods currently being investigated. In particular, additive manufacturing shows promise as a technique to control pore size and shape for optimum biological properties.

  16. 75 FR 16511 - Pentron Clinical Technologies, a Wholly-Owned Subsidiary of Kerr Dental/Sybron Dental...

    Science.gov (United States)

    2010-04-01

    ... produce dental materials such as dental prosthetics, dental composites, dental impressions, dental... materials such as dental prosthetics, dental composites, dental impressions, dental adhesives, and other... Technologies, a Wholly-Owned Subsidiary of Kerr Dental/Sybron Dental Specialities, Formally Known as Customedix...

  17. Finite element analysis (FEA) of dental implant fixture for mechanical stability and rapid osseointegration

    Science.gov (United States)

    Tabassum, Shafia; Murtaza, Ahmar; Ali, Hasan; Uddin, Zia Mohy; Zehra, Syedah Sadaf

    2017-10-01

    For rapid osseointegration of dental implant fixtures, various surface treatments including plasma spraying, hydroxyapatite coating, acid-etching, and surface grooving are used. However undesirable effects such as chemical modifications, loss of mechanical properties, prolonged processing times and post production treatment steps are often associated with these techniques. The osseointegration rate of the dental implants can be promoted by increasing the surface area of the dental implant, thus increasing the bone cells - implant material contact and allow bone tissues to grow rapidly. Additive Manufacturing (AM) techniques can be used to fabricate dental implant fixtures with desirable surface area in a single step manufacturing process. AM allows the use of Computer Aided Designing (CAD) for customised rapid prototyping of components with precise control over geometry. In this study, the dental implant fixture that replaces the tooth root was designed on commercially available software COMSOL. Nickel - titanium alloy was selected as build materials for dental implant. The geometry of the dental fixture was varied by changing the interspacing distance (thread pitch) and number of threads to increase the total surface area. Three different microstructures were introduced on the surface of dental implant. The designed models were used to examine the effect of changing geometries on the total surface area. Finite Element Analysis (FEA) was performed to investigate the effect of changing geometries on the mechanical properties of the dental implant fixtures using stress analysis.

  18. Grindability of cast Ti-Hf alloys.

    Science.gov (United States)

    Kikuchi, Masafumi; Takahashi, Masatoshi; Sato, Hideki; Okuno, Osamu; Nunn, Martha E; Okabe, Toru

    2006-04-01

    As part of our systematic studies characterizing the properties of titanium alloys, we investigated the grindability of a series of cast Ti-Hf alloys. Alloy buttons with hafnium concentrations up to 40 mass% were made using an argon-arc melting furnace. Each button was cast into a magnesia-based mold using a dental titanium casting machine; three specimens were made for each metal. Prior to testing, the hardened surface layer was removed. The specimens were ground at five different speeds for 1 min at 0.98 N using a carborundum wheel on an electric dental handpiece. Grindability was evaluated as the volume of metal removed per minute (grinding rate) and the volume ratio of metal removed compared to the wheel material lost (grinding ratio). The data were analyzed using ANOVA. A trend of increasing grindability was found with increasing amounts of hafnium, although there was no statistical difference in the grindability with increasing hafnium contents. We also found that hafnium may be used to harden or strengthen titanium without deteriorating the grindability.

  19. Antibacterial effect of copper-bearing titanium alloy (Ti-Cu) against Streptococcus mutans and Porphyromonas gingivalis

    Science.gov (United States)

    Liu, Rui; Memarzadeh, Kaveh; Chang, Bei; Zhang, Yumei; Ma, Zheng; Allaker, Robert P.; Ren, Ling; Yang, Ke

    2016-07-01

    Formation of bacterial biofilms on dental implant material surfaces (titanium) may lead to the development of peri-implant diseases influencing the long term success of dental implants. In this study, a novel Cu-bearing titanium alloy (Ti-Cu) was designed and fabricated in order to efficiently kill bacteria and discourage formation of biofilms, and then inhibit bacterial infection and prevent implant failure, in comparison with pure Ti. Results from biofilm based gene expression studies, biofilm growth observation, bacterial viability measurements and morphological examination of bacteria, revealed antimicrobial/antibiofilm activities of Ti-Cu alloy against the oral specific bacterial species, Streptococcus mutans and Porphyromonas gingivalis. Proliferation and adhesion assays with mesenchymal stem cells, and measurement of the mean daily amount of Cu ion release demonstrated Ti-Cu alloy to be biocompatible. In conclusion, Ti-Cu alloy is a promising dental implant material with antimicrobial/antibiofilm activities and acceptable biocompatibility.

  20. Translating VDM to Alloy

    DEFF Research Database (Denmark)

    Lausdahl, Kenneth

    2013-01-01

    specifications. However, to take advantage of the automated analysis of Alloy, the model-oriented VDM specifications must be translated into a constraint-based Alloy specifications. We describe how a sub- set of VDM can be translated into Alloy and how assertions can be expressed in VDM and checked by the Alloy...

  1. Mineral-PET Kimberlite sorting by nuclear-medical technology

    CERN Document Server

    Ballestrero, S; Cafferty, L; Caveney, R; Connell, SH; Cook, M; Dalton, M; Gopal, H; Ives, N; Lee, C A; Mampe, W; Phoku, M; Roodt, A; Sibande, W; Sellschop, J P F; Topkin, J; Unwucholaa, D A

    2010-01-01

    A revolutionary new technology for diamond bearing rock sorting which has its roots in medical-nuclear physics has been taken through a substantial part of the R&D phase. This has led to the construction of the technology demonstrator. Experiments using the technology demonstrator and experiments at a hospital have established the scientific and technological viability of the project.

  2. Image processing. A system for the automatic sorting of chromosomes

    International Nuclear Information System (INIS)

    Najai, Amor

    1977-01-01

    The present paper deals with two aspects of the system: - an automata (specialized hardware) dedicated to image processing. Images are digitized, divided into sub-units and computations are carried out on their main parameters. - A software for the automatic recognition and sorting of chromosomes is implemented on a Multi-20 minicomputer, connected to the automata. (author) [fr

  3. System for sorting microscopic objects using electromagnetic radiation

    DEFF Research Database (Denmark)

    2013-01-01

    There is presented a system 10,100 for sorting microscopic objects 76, 78, 80, where the system comprises a fluid channel 66 with an inlet 68 and an outlet 70, where the fluid channel is arranged for allowing the fluid flow to be laminar. The system furthermore comprises a detection system 52 whi...

  4. Dielectrophoretic focusing integrated pulsed laser activated cell sorting

    Science.gov (United States)

    Zhu, Xiongfeng; Kung, Yu-Chun; Wu, Ting-Hsiang; Teitell, Michael A.; Chiou, Pei-Yu

    2017-08-01

    We present a pulsed laser activated cell sorter (PLACS) integrated with novel sheathless size-independent dielectrophoretic (DEP) focusing. Microfluidic fluorescence activated cell sorting (μFACS) systems aim to provide a fully enclosed environment for sterile cell sorting and integration with upstream and downstream microfluidic modules. Among them, PLACS has shown a great potential in achieving comparable performance to commercial aerosol-based FACS (>90% purity at 25,000 cells sec-1). However conventional sheath flow focusing method suffers a severe sample dilution issue. Here we demonstrate a novel dielectrophoresis-integrated pulsed laser activated cell sorter (DEP-PLACS). It consists of a microfluidic channel with 3D electrodes laid out to provide a tunnel-shaped electric field profile along a 4cmlong channel for sheathlessly focusing microparticles/cells into a single stream in high-speed microfluidic flows. All focused particles pass through the fluorescence detection zone along the same streamline regardless of their sizes and types. Upon detection of target fluorescent particles, a nanosecond laser pulse is triggered and focused in a neighboring channel to generate a rapidly expanding cavitation bubble for precise sorting. DEP-PLACS has achieved a sorting purity of 91% for polystyrene beads at a throughput of 1,500 particle/sec.

  5. Real-time implementation of a color sorting system

    Science.gov (United States)

    Srikanteswara, Srikathyanyani; Lu, Qiang O.; King, William; Drayer, Thomas H.; Conners, Richard W.; Kline, D. Earl; Araman, Philip A.

    1997-09-01

    Wood edge glued panels are used extensively in the furniture and cabinetry industries. They are used to make doors, tops, and sides of solid wood furniture and cabinets. Since lightly stained furniture and cabinets are gaining in popularity, there is an increasing demand to color sort the parts used to make these edge glued panels. The goal of the sorting processing is to create panels that are uniform in both color and intensity across their visible surface. If performed manually, the color sorting of edge-glued panel parts is very labor intensive and prone to error. This paper describes a complete machine vision system for performing this sort. This system uses two color line scan cameras for image input and a specially designed custom computing machine to allow real-time implementation. Users define the number of color classes that are to be used. An 'out' class is provided to handle unusually colored parts. The system removes areas of character mark, e.g., knots, mineral streak, etc., from consideration when assigning a color class to a part. The system also includes a better face algorithm for determining which part face would be the better to put on the side of the panel that will show. The throughput is two linear feet per second. Only a four inch between part spacing is required. This system has undergone extensive in plant testing and will be commercially available in the very near future. The results of this testing will be presented.

  6. A correctness proof of sorting by means of formal procedures

    NARCIS (Netherlands)

    Fokkinga, M.M.

    1987-01-01

    We consider a recursive sorting algorithm in which, in each invocation, a new variable and a new procedure (using the variable globally) are defined and the procedure is passed to recursive calls. This algorithm is proved correct with Hoare-style pre- and postassertions. We also discuss the same

  7. Sorting, Searching, and Simulation in the MapReduce Framework

    DEFF Research Database (Denmark)

    Goodrich, Michael T.; Sitchinava, Nodar; Zhang, Qin

    2011-01-01

    We study the MapReduce framework from an algorithmic standpoint, providing a generalization of the previous algorithmic models for MapReduce. We present optimal solutions for the fundamental problems of all-prefix-sums, sorting and multi-searching. Additionally, we design optimal simulations...

  8. An efficient non-dominated sorting method for evolutionary algorithms.

    Science.gov (United States)

    Fang, Hongbing; Wang, Qian; Tu, Yi-Cheng; Horstemeyer, Mark F

    2008-01-01

    We present a new non-dominated sorting algorithm to generate the non-dominated fronts in multi-objective optimization with evolutionary algorithms, particularly the NSGA-II. The non-dominated sorting algorithm used by NSGA-II has a time complexity of O(MN(2)) in generating non-dominated fronts in one generation (iteration) for a population size N and M objective functions. Since generating non-dominated fronts takes the majority of total computational time (excluding the cost of fitness evaluations) of NSGA-II, making this algorithm faster will significantly improve the overall efficiency of NSGA-II and other genetic algorithms using non-dominated sorting. The new non-dominated sorting algorithm proposed in this study reduces the number of redundant comparisons existing in the algorithm of NSGA-II by recording the dominance information among solutions from their first comparisons. By utilizing a new data structure called the dominance tree and the divide-and-conquer mechanism, the new algorithm is faster than NSGA-II for different numbers of objective functions. Although the number of solution comparisons by the proposed algorithm is close to that of NSGA-II when the number of objectives becomes large, the total computational time shows that the proposed algorithm still has better efficiency because of the adoption of the dominance tree structure and the divide-and-conquer mechanism.

  9. Sorting genomes by reciprocal translocations, insertions, and deletions.

    Science.gov (United States)

    Qi, Xingqin; Li, Guojun; Li, Shuguang; Xu, Ying

    2010-01-01

    The problem of sorting by reciprocal translocations (abbreviated as SBT) arises from the field of comparative genomics, which is to find a shortest sequence of reciprocal translocations that transforms one genome Pi into another genome Gamma, with the restriction that Pi and Gamma contain the same genes. SBT has been proved to be polynomial-time solvable, and several polynomial algorithms have been developed. In this paper, we show how to extend Bergeron's SBT algorithm to include insertions and deletions, allowing to compare genomes containing different genes. In particular, if the gene set of Pi is a subset (or superset, respectively) of the gene set of Gamma, we present an approximation algorithm for transforming Pi into Gamma by reciprocal translocations and deletions (insertions, respectively), providing a sorting sequence with length at most OPT + 2, where OPT is the minimum number of translocations and deletions (insertions, respectively) needed to transform Pi into Gamma; if Pi and Gamma have different genes but not containing each other, we give a heuristic to transform Pi into Gamma by a shortest sequence of reciprocal translocations, insertions, and deletions, with bounds for the length of the sorting sequence it outputs. At a conceptual level, there is some similarity between our algorithm and the algorithm developed by El Mabrouk which is used to sort two chromosomes with different gene contents by reversals, insertions, and deletions.

  10. Incentives versus sorting in tournaments: evidence from a field experiment

    NARCIS (Netherlands)

    Leuven, E.; Oosterbeek, H.; Sonnemans, J.; van der Klaauw, B.

    2011-01-01

    Existing field evidence on rank-order tournaments typically does not allow disentangling incentive and sorting effects. We conduct a field experiment illustrating the confounding effect. Students in an introductory microeconomics course selected themselves into tournaments with low, medium, or high

  11. A methodical approach for the assessment of waste sorting plants

    NARCIS (Netherlands)

    Feil, Alexander; Pretz, Thomas; Vitz, Philipp; Thoden van Velzen, Ulphard

    2017-01-01

    A techno-economical evaluation of the processing result of waste sorting plants should at least provide a realistic assessment of the recovery yields of valuable materials and of the qualities of the obtained products. This practical data is generated by weighing all the output products and

  12. Sorting Tubules Regulate Blood-Brain Barrier Transcytosis

    Directory of Open Access Journals (Sweden)

    Roberto Villaseñor

    2017-12-01

    Full Text Available Transcytosis across the blood-brain barrier (BBB regulates key processes of the brain, but the intracellular sorting mechanisms that determine successful receptor-mediated transcytosis in brain endothelial cells (BECs remain unidentified. Here, we used Transferrin receptor-based Brain Shuttle constructs to investigate intracellular transport in BECs, and we uncovered a pathway for the regulation of receptor-mediated transcytosis. By combining live-cell imaging and mathematical modeling in vitro with super-resolution microscopy of the BBB, we show that intracellular tubules promote transcytosis across the BBB. A monovalent construct (sFab sorted for transcytosis was localized to intracellular tubules, whereas a bivalent construct (dFab sorted for degradation formed clusters with impaired transport along tubules. Manipulating tubule biogenesis by overexpressing the small GTPase Rab17 increased dFab transport into tubules and induced its transcytosis in BECs. We propose that sorting tubules regulate transcytosis in BECs and may be a general mechanism for receptor-mediated transport across the BBB.

  13. Sphingolipid trafficking and protein sorting in epithelial cells

    NARCIS (Netherlands)

    Slimane, TA; Hoekstra, D

    2002-01-01

    Sphingolipids represent a minor, but highly dynamic subclass of lipids in all eukaryotic cells. They are involved in functions that range from structural protection to signal transduction and protein sorting, and participate in lipid raft assembly. In polarized epithelial cells, which display an

  14. AMDLIBGZ, IBM 360 Subroutine Library for Data Processing, Graphics, Sorting

    International Nuclear Information System (INIS)

    Wang, Jesse Y.

    1980-01-01

    Description of problem or function: AMDLIBGZ is a subset of the IBM 360 Subroutine Library at the Applied Mathematics Division at Argonne National Laboratory. This subset includes library categories G-Z: Identification/Description: G552S F RANF: Random number generator; J952S F YOLYPLOT: CalComp plots; J955S P GRAF: Prints a graph of points on line printer; K250S A1: Core to core conversion; K251S A HEXINP: Hexadecimal input for PL/I programs; K252S A HEXOUT: Hexadecimal output conv. PL/I programs; M101S F SORT: Algebraic sort; M150S F CSORT: Algebraic sort; M151S P2 ANLKWIC: KWIC sort; M250S A SMALLIST: Squeezes assembler listing to 8 x 11; N251S A ABEND: Calls ABEND dump; Q052S A CLOCK: Time; Q053S A COPYAGO: Copy load module from tape to disk; Q054S A DATE: Current date in form MM/DD/YY; Q055S A TIME: Time (24 hour clock) in EBCDIC HH.MM.SS; Z013S F: Variable metric minimization; Z057S A LOCF: Locate machine addresses of variables; Z071S A ALLOC: Allocate LCS for FORTRAN programs; Z074S A ANLMNP: Exponent and mantissa manipulative functs.

  15. Towards understanding and managing the learning process in mail sorting.

    Science.gov (United States)

    Berglund, M; Karltun, A

    2012-01-01

    This paper was based on case study research at the Swedish Mail Service Division and it addresses learning time to sort mail at new districts and means to support the learning process on an individual as well as organizational level. The study population consisted of 46 postmen and one team leader in the Swedish Mail Service Division. Data were collected through measurements of time for mail sorting, interviews and a focus group. The study showed that learning to sort mail was a much more complex process and took more time than expected by management. Means to support the learning process included clarification of the relationship between sorting and the topology of the district, a good work environment, increased support from colleagues and management, and a thorough introduction for new postmen. The identified means to support the learning process require an integration of human, technological and organizational aspects. The study further showed that increased operations flexibility cannot be reinforced without a systems perspective and thorough knowledge about real work activities and that ergonomists can aid businesses to acquire this knowledge.

  16. Udpegning af potentielle sorte pletter via floating car data

    DEFF Research Database (Denmark)

    Splid Svendsen, Martin; Tradisauskas, Nerius; Lahrmann, Harry

    2008-01-01

    Formålet med dette paper er at undersøge, om det er muligt at udpege potentielle sorte pletter via floating car data. Der er i projektet udført teoretiske litteraturstudier for at skabe et grundlag for det senere analysearbejde, som danner baggrund for analysearbejdet. Dataene stammer fra Aalborg...

  17. Pure chromosome-specific PCR libraries from single sorted chromosomes

    NARCIS (Netherlands)

    VanDevanter, D. R.; Choongkittaworn, N. M.; Dyer, K. A.; Aten, J. A.; Otto, P.; Behler, C.; Bryant, E. M.; Rabinovitch, P. S.

    1994-01-01

    Chromosome-specific DNA libraries can be very useful in molecular and cytogenetic genome mapping studies. We have developed a rapid and simple method for the generation of chromosome-specific DNA sequences that relies on polymerase chain reaction (PCR) amplification of a single flow-sorted

  18. Optical sorting and photo-transfection of mammalian cells

    CSIR Research Space (South Africa)

    Mthunzi, P

    2010-02-01

    Full Text Available and that the scattering force can enable sorting through axial guiding onto laminin coated glass coverslips upon which the selected cells adhere. Following this, I report on transient photo-transfection of mammalian cells including neuroblastomas (rat/mouse and human...

  19. Support for designing waste sorting systems: A mini review.

    Science.gov (United States)

    Rousta, Kamran; Ordoñez, Isabel; Bolton, Kim; Dahlén, Lisa

    2017-11-01

    This article presents a mini review of research aimed at understanding material recovery from municipal solid waste. It focuses on two areas, waste sorting behaviour and collection systems, so that research on the link between these areas could be identified and evaluated. The main results presented and the methods used in the articles are categorised and appraised. The mini review reveals that most of the work that offered design guidelines for waste management systems was based on optimising technical aspects only. In contrast, most of the work that focused on user involvement did not consider developing the technical aspects of the system, but was limited to studies of user behaviour. The only clear consensus among the articles that link user involvement with the technical system is that convenient waste collection infrastructure is crucial for supporting source separation. This mini review reveals that even though the connection between sorting behaviour and technical infrastructure has been explored and described in some articles, there is still a gap when using this knowledge to design waste sorting systems. Future research in this field would benefit from being multidisciplinary and from using complementary methods, so that holistic solutions for material recirculation can be identified. It would be beneficial to actively involve users when developing sorting infrastructures, to be sure to provide a waste management system that will be properly used by them.

  20. System of radwaste sorting out physical features and activities

    International Nuclear Information System (INIS)

    Batij, V.G.; Kuz'menko, V.A.; Bozhko, V.P.; Ganenko, V.B.; Olejnik, S.N.

    2000-01-01

    Classification of radioactive waste sources in Ukraine is provided. General technological sorting scheme of the RAW of chiefly. Chernobyl origin is offered. Some measures to treat short-lived and long-lived High-Level Waste, Intermediate-Active Waste and Low-Level Active Waste in the Center for waste treatment and disposal are offered. 4 refs., 2 tab., 8 figs

  1. Dental Anomalies: An Update

    Directory of Open Access Journals (Sweden)

    Fatemeh Jahanimoghadam

    2016-01-01

    Full Text Available Dental anomalies are usual congenital malformation that can happen either as isolated findings or as a part of a syndrome. Developmental anomalies influencing the morphology exists in both deciduous and permanent dentition and shows different forms such as gemination, fusion, concrescence, dilaceration, dens evaginatus (DE, enamel pearls, taurodontism or peg-shaped laterals. All These anomalies have clinical significance concerning aesthetics, malocclusion and more necessary preparing of the development of dental decays and oral diseases. Through a search in PubMed, Google, Scopus and Medline, a total of eighty original research papers during 1928-2016 were found with the keywords such as dental anomaly, syndrome, tooth and hypodontia. One hundred review titles were identified, eighty reviews were retrieved that were finally included as being relevant and of sufficient quality. In this review, dental anomalies including gemination, fusion, concrescence, dilaceration, dens invaginatus, DE, taurodontism, enamel pearls, fluorosis, peg-shaped laterals, dentinal dysplasia, regional odontodysplasia and hypodontia are discussed. Diagnosing dental abnormality needs a thorough evaluation of the patient, involving a medical, dental, familial and clinical history. Clinical examination and radiographic evaluation and in some of the cases, specific laboratory tests are also needed. Developmental dental anomalies require careful examination and treatment planning. Where one anomaly is present, clinicians should suspect that other anomalies may also be present. Moreover, careful clinical and radiographical examination is required. Furthermore, more complex cases need multidisciplinary planning and treatment.

  2. Alternative materials study for dental magnetics attachments applications

    International Nuclear Information System (INIS)

    Marques, Rogerio Albuquerque

    2009-01-01

    Ferromagnetic alloys have been investigated as potential candidates for dental prosthesis applications in replacement for magnetic attachments made of noble and expensive alloys. Three stainless steels were investigated: 17-4 PH produced by powder injection (PIM), PM2000 obtained by mechanical alloying and oxide dispersion strengthened, and nickel free stainless steel 1802. In the in vitro cytotoxicity analysis, none of the three steels tested showed cytotoxic effects. The corrosion resistance of stainless steels was evaluated by electrochemical impedance spectroscopy (EIS) and anodic potentiodynamic polarization, in sodium phosphate buffer solutions (PBS) at 25 degree C. The AISI 316L stainless steel was also tested under the same conditions for comparison reasons. All the stainless steel samples were passive in the electrolyte used and presented susceptibility to pitting. The steel that showed the highest pitting resistance was the PM2000, whereas the 1802 had the lowest resistance to pitting among the tested ones. The Mott-Schottky diagrams suggested that the passive film over the surface of PM2000 steel is at least one decade less doped compared to 316L stainless steel, so less defective in its structure. The results pointed out to the PM2000 as a potential candidate for substitution of high cost magnetic alloys used in dental prosthesis. (author)

  3. Macro design morphology of endosseous dental implants.

    Science.gov (United States)

    Sahiwal, Indira G; Woody, Ronald D; Benson, Byron W; Guillen, Guillermo E

    2002-05-01

    The identification of dental implant bodies in patients without available records is a considerable problem due to increased patient mobility and to the large number of implant systems with different designs. The purpose of this study was to document the designs of selected implants to help clinicians identify these implants from their radiographic images. More than 50 implant manufacturers were contacted and asked to provide implants with dimensions as close as possible to 3.75 mm (diameter) x 10 mm (length). Forty-four implants were donated, separated into threaded and non-threaded categories, and further sorted into tapered and non-tapered categories. The implants were examined visually, and features on the entire circumference and length of each implant were recorded and categorized as coronal, midbody, or apical. A series of tables describe the 44 implants according to coronal, midbody, and apical features. The results of this project offer dentists basic knowledge of the design of selected dental implants. Such knowledge can aid the radiographic identification of these implants.

  4. Equine dental advances.

    Science.gov (United States)

    Greene, S K

    2001-08-01

    The reintroduction and development of safe motorized instruments, the increased availability of continuing education, and the understanding and implementation of appropriate procedures allow practitioners to provide better dental care. Veterinarians realize that sedation, analgesia, a full-mouth speculum, and proper instrumentation are necessary to provide these services. Continued instrument design, future research, and new treatment and prophylactic protocols should have a positive impact on the future of equine dental health. New and rediscovered procedures for equilibrating equine occlusion are allowing horses to masticate more efficiently, carry a bit more comfortably, and experience improved performance. The horse, the horse owner, and the veterinary profession all benefit from providing complete equine dental care.

  5. Dental biofilm infections

    DEFF Research Database (Denmark)

    Larsen, Tove; Fiehn, Nils-Erik

    2017-01-01

    and cause gingival inflammation and breakdown of supporting periodontal fibers and bone and ultimately tooth loss, i.e., gingivitis, chronic or aggressive periodontitis, and around dental implants, peri-implantitis. Furthermore, bacteria from the dental biofilm may spread to other parts of the body......-fermenting bacteria causing demineralization of teeth, dental caries, which may further lead to inflammation and necrosis in the pulp and periapical region, i.e., pulpitis and periapical periodontitis. In supra- and subgingival biofilms, predominantly gram-negative, anaerobic proteolytic bacteria will colonize...

  6. Dental Trauma Guide

    DEFF Research Database (Denmark)

    Andreasen, Jens Ove; Lauridsen, Eva; Gerds, Thomas Alexander

    2012-01-01

    Diagnosis and treatment for traumatic dental injuries are very complex owing to the multiple trauma entities represented by six luxation types and nine fracture types affecting both the primary and the permanent dentition. When it is further considered that fracture and luxation injuries are often...... problems in selecting proper treatment for some of these trauma types. To remedy this situation, an Internet-based knowledge base consisting of 4000 dental trauma cases with long-term follow up is now available to the public and the professions on the Internet using the address http://www.Dental...

  7. Optimization of dental implantation

    Science.gov (United States)

    Dol, Aleksandr V.; Ivanov, Dmitriy V.

    2017-02-01

    Modern dentistry can not exist without dental implantation. This work is devoted to study of the "bone-implant" system and to optimization of dental prostheses installation. Modern non-invasive methods such as MRI an 3D-scanning as well as numerical calculations and 3D-prototyping allow to optimize all of stages of dental prosthetics. An integrated approach to the planning of implant surgery can significantly reduce the risk of complications in the first few days after treatment, and throughout the period of operation of the prosthesis.

  8. Parallel sort with a ranged, partitioned key-value store in a high perfomance computing environment

    Science.gov (United States)

    Bent, John M.; Faibish, Sorin; Grider, Gary; Torres, Aaron; Poole, Stephen W.

    2016-01-26

    Improved sorting techniques are provided that perform a parallel sort using a ranged, partitioned key-value store in a high performance computing (HPC) environment. A plurality of input data files comprising unsorted key-value data in a partitioned key-value store are sorted. The partitioned key-value store comprises a range server for each of a plurality of ranges. Each input data file has an associated reader thread. Each reader thread reads the unsorted key-value data in the corresponding input data file and performs a local sort of the unsorted key-value data to generate sorted key-value data. A plurality of sorted, ranged subsets of each of the sorted key-value data are generated based on the plurality of ranges. Each sorted, ranged subset corresponds to a given one of the ranges and is provided to one of the range servers corresponding to the range of the sorted, ranged subset. Each range server sorts the received sorted, ranged subsets and provides a sorted range. A plurality of the sorted ranges are concatenated to obtain a globally sorted result.

  9. Denni Algorithm An Enhanced Of SMS (Scan, Move and Sort) Algorithm

    Science.gov (United States)

    Aprilsyah Lubis, Denni; Salim Sitompul, Opim; Marwan; Tulus; Andri Budiman, M.

    2017-12-01

    Sorting has been a profound area for the algorithmic researchers, and many resources are invested to suggest a more working sorting algorithm. For this purpose many existing sorting algorithms were observed in terms of the efficiency of the algorithmic complexity. Efficient sorting is important to optimize the use of other algorithms that require sorted lists to work correctly. Sorting has been considered as a fundamental problem in the study of algorithms that due to many reasons namely, the necessary to sort information is inherent in many applications, algorithms often use sorting as a key subroutine, in algorithm design there are many essential techniques represented in the body of sorting algorithms, and many engineering issues come to the fore when implementing sorting algorithms., Many algorithms are very well known for sorting the unordered lists, and one of the well-known algorithms that make the process of sorting to be more economical and efficient is SMS (Scan, Move and Sort) algorithm, an enhancement of Quicksort invented Rami Mansi in 2010. This paper presents a new sorting algorithm called Denni-algorithm. The Denni algorithm is considered as an enhancement on the SMS algorithm in average, and worst cases. The Denni algorithm is compared with the SMS algorithm and the results were promising.

  10. Economic impact of dental hygienists on solo dental practices.

    Science.gov (United States)

    Lazar, Vickie F; Guay, Albert H; Beazoglou, Tryfon J

    2012-08-01

    The fact that a significant percentage of dentists employ dental hygienists raises an important question: Are dental practices that utilize a dental hygienist structurally and operationally different from practices that do not? This article explores differences among dental practices that operate with and without dental hygienists. Using data from the American Dental Association's 2003 Survey of Dental Practice, a random sample survey of U.S. dentists, descriptive statistics were used to compare selected characteristics of solo general practitioners with and without dental hygienists. Multivariate regression analysis was used to estimate the effect of dental hygienists on the gross billings and net incomes of solo general practitioners. Differences in practice characteristics--such as hours spent in the practice and hours spent treating patients, wait time for a recall visit, number of operatories, square feet of office space, net income, and gross billings--were found between solo general practitioners who had dental hygienists and those who did not. Solo general practitioners with dental hygienists had higher gross billings. Higher gross billings would be expected, as would higher expenses. However, net incomes of those with dental hygienists were also higher. In contrast, the mean waiting time for a recall visit was higher among dentists who employed dental hygienists. Depending on personal preferences, availability of qualified personnel, etc., dentists who do not employ dental hygienists but have been contemplating that path may want to further research the benefits and opportunities that may be realized.

  11. Assessment of exposures and potential risks to the US adult population from wear (attrition and abrasion) of gold and ceramic dental restorations.

    Science.gov (United States)

    Richardson, G Mark; Clemow, Scott R; Peters, Rachel E; James, Kyle J; Siciliano, Steven D

    2016-01-01

    Little has been published on the chemical exposures and risks of dental restorative materials other than from dental amalgam and composite resins. Here we provide the first exposure and risk assessment for gold (Au) alloy and ceramic restorative materials. Based on the 2001-2004 US National Health and Nutrition Examination Survey (NHANES), we assessed the exposure of US adults to the components of Au alloy and ceramic dental restorations owing to dental material wear. Silver (Ag) is the most problematic component of Au alloy restorations, owing to a combination of toxicity and proportional composition. It was estimated that adults could possess an average of four tooth surfaces restored with Au alloy before exceeding, on average, the reference exposure level (REL) for Ag. Lithium (Li) is the most problematic component of dental ceramics. It was estimated that adults could possess an average of 15 tooth surfaces restored with ceramics before exceeding the REL for Li. Relative risks of chemical exposures from dental materials decrease in the following order: Amalgam>Au alloys>ceramics>composite resins.

  12. A Quality Sorting of Fruit Using a New Automatic Image Processing Method

    Science.gov (United States)

    Amenomori, Michihiro; Yokomizu, Nobuyuki

    This paper presents an innovative approach for quality sorting of objects such as apples sorting in an agricultural factory, using an image processing algorithm. The objective of our approach are; firstly to sort the objects by their colors precisely; secondly to detect any irregularity of the colors surrounding the apples efficiently. An experiment has been conducted and the results have been obtained and compared with that has been preformed by human sorting process and by color sensor sorting devices. The results demonstrate that our approach is capable to sort the objects rapidly and the percentage of classification valid rate was 100 %.

  13. Orthodontic applications of a superelastic shape-memory alloy model

    Energy Technology Data Exchange (ETDEWEB)

    Glendenning, R.W.; Enlow, R.L. [Otago Univ., Dunedin (New Zealand). Dept. of Math. and Stat.; Hood, J.A.A. [Dept. of Oral Sciences and Orthodontics, Univ. of Otago, Dunedin (New Zealand)

    2000-07-01

    During orthodontic treatment, dental appliances (braces) made of shape memory alloys have the potential to provide nearly uniform low level stresses to dentitions during tooth movement over a large range of tooth displacement. In this paper we model superelastic behaviour of dental appliances using the finite element method and constitutive equations developed by F. Auricchio et al. Results of the mathematical model for 3-point bending and several promising 'closing loop' designs are compared with laboratory results for the same configurations. (orig.)

  14. Dental education in Kuwait.

    Science.gov (United States)

    Behbehani, J M

    2003-01-01

    For a long time there has been a need to establish a dental school in Kuwait, due to the fact that the majority of dentists working in Kuwait are expatriates from various countries. An Amiri decree in 1996 made it possible, and the first dental students were admitted to the Kuwait University Faculty of Dentistry in 1998. The mission of the Faculty of Dentistry is 'to promote oral health in Kuwait through education, research and cooperation with other professional health care institutions as well as the community at large'. A 6.5-year dental curriculum was completed after 2 years of committee work and was accepted by the University Council in 2001. This curriculum incorporates current trends in medical and dental education, such as the evidence-based and community-based approaches, problem-solving methodology for outcome-based learning, and competency achieved through comprehensive patient care. Copyright 2003 S. Karger AG, Basel

  15. Xilitol and dental caries.

    NARCIS (Netherlands)

    Smits, Marten Titus

    1987-01-01

    Dental caries is a widespread multifactoral disease. The main sympthons are minaral loss from tooth enemal and dentine, eventually leading to total destruction of the teeth, pain, impairment of mastication and problems with facial esthetics. ... Zie: Summary

  16. Advances in dental imaging.

    Science.gov (United States)

    Brown, J E

    2001-04-01

    The number of dental radiographs taken in the UK has steadily increased over the past 20 years--recently estimating around 18 million taken in the general dental services alone, and dental radiographs now account for nearly 25% of all medical radiographic exposures. Radiographs remain our most useful diagnostic aid. Their strength is in demonstrating hard tissue pathology, which makes radiographs particularly effective in the maxillofacial region. Although well accepted in this capacity, there remain a number of limitations and drawbacks to conventional radiographs which recent developments have begun to overcome. There have been improvements in the scope and capabilities of dental imaging equipment. There has also been a continuing effort to reduce radiation-induced harm by limiting our exposure to it. This has been possible both through the introduction of new methods and protocols for reducing individual radiation exposures and by the creation of guidelines for selecting radiographs more effectively and thereby reducing the total number of radiographs taken.

  17. Dental care - child

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002213.htm Dental care - child To use the sharing features on ... please enable JavaScript. Proper care of your child's teeth and gums includes brushing and rinsing daily. It ...

  18. Dental Exam for Children

    Science.gov (United States)

    ... risks associated with tobacco, substance abuse and oral piercings. Why it's done Regular dental exams help protect ... sugary beverages Smoking Chewing tobacco Eating disorders Oral piercings Not wearing a mouthguard during contact sports The ...

  19. Nigerian Dental Journal: Submissions

    African Journals Online (AJOL)

    INSTRUCTIONS FOR AUTHORS AND CONTRIBUTORS The Nigerian Dental ... review articles, clinical case reports and innovations in surgical techniques ... figures and illustrations, including one copy stored in a 3.5” floppy should be sent to ...

  20. Dental Assisting Program Standards.

    Science.gov (United States)

    Georgia Univ., Athens. Dept. of Vocational Education.

    This publication contains statewide standards for the dental assisting program in Georgia. The standards are divided into 12 categories: foundations (philosophy, purpose, goals, program objectives, availability, evaluation); admissions (admission requirements, provisional admission requirements, recruitment, evaluation and planning); program…

  1. Resin Composites Reinforced by Nanoscaled Fibers or Tubes for Dental Regeneration

    Science.gov (United States)

    Li, Xiaoming; Liu, Wei; Sun, Lianwen; Aifantis, Katerina E.; Yu, Bo; Fan, Yubo; Cui, Fuzhai; Watari, Fumio

    2014-01-01

    It has been stated clearly that nanofillers could make an enhancement on the mechanical performances of dental composites. In order to address current shortage of traditional dental composites, fillers in forms of nanofibers or nanotubes are broadly regarded as ideal candidates to greatly increase mechanical performances of dental composites with low content of fillers. In this review, the efforts using nanofibers and nanotubes to reinforce mechanical performances of dental composites, including polymeric nanofibers, metallic nanofibers or nanotubes, and inorganic nanofibers or nanotubes, as well as their researches related, are demonstrated in sequence. The first purpose of current paper was to confirm the enhancement of nanofibers or nanotubes' reinforcement on the mechanical performances of dental restorative composite. The second purpose was to make a general description about the reinforcement mechanism of nanofibers and nanotubes, especially, the impact of formation of interphase boundary interaction and nanofibers themselves on the advanced mechanical behaviors of the dental composites. By means of the formation of interface interaction and poststretching nanofibers, reinforced effect of dental composites by sorts of nanofibers/nanotubes has been successfully obtained. PMID:24982894

  2. Comparative investigation of smooth polycrystalline diamond films on dental burs by chemical vapor deposition

    Science.gov (United States)

    Sein, Htet; Ahmed, Waqar; Rego, Christopher; Jackson, Mark; Polini, Riccardo

    2006-04-01

    Depositions of hot filament chemical vapor-deposited diamond on cobalt-cemented tungsten carbide (WC-Co) rotary cutting dental burs are presented. Conventional dental tools made of sintered polycrystalline diamond have a number of problems associated with the heterogeneity of the crystallite, decreased cutting efficiency, and short life. A preferential (111) faceted diamond was obtained after 15 h of deposition at a growth rate of 1.1 µm/h. Diamond-coated WC-Co dental burs and conventional sintered burs are mainly used in turning, milling, and drilling operations for machining metal ceramic hard alloys such as CoCr, composite teeth, and aluminum alloy in the dental laboratory. The influence of structure, the mechanical characteristics of both diamond grains and hard alloys on the wear behavior, as well as the regimen of grinding on diamond wear are considered. Erosion wear properties are also investigated under air-sand erosion testing. After machining with excessive cutting performance, calculations can be made on flank and crater wear areas. Diamond-coated WC-Co dental burs offered significantly better erosion and wear resistance compared with uncoated WC-Co tools and sintered burs.

  3. Steel alloys

    International Nuclear Information System (INIS)

    Bloom, E.E.; Stiegler, J.O.; Rowcliffe, A.F.; Leitnaker, J.M.

    1977-01-01

    The invention deals with a fuel element for fast breeder reactors. It consits essentially of a uranium oxide, nitride, or carbide or a mixture of these fuels with a plutonium or thorium oxide, nitride, or carbide. The fuel elements are coated with an austenitic stainless steel alloy. Inside the fuel elements, vacancies or small cavities are produced by neutron effects which causes the steel coating to swell. According to the invention, swelling is prevented by a modification of type 304, 316, 321, or 12 K 72HV commercial steels. They consist mainly of Fe, Cr, and Ni in a ratio determined by a temary diagram. They may also contain 1.8 to 2.3% by weight of Mo and a fraction of Si (0.7 to 2% by weight) and Ti(0.10 to 0.5% by weight) to prevent cavity formation. They are structurally modified by cold working. (IHOE) [de

  4. Campus-Based, Community-Based, and Philanthropic Contributions to Predoctoral Pediatric Dental Clinical Education: Two Years of Experiences at One Dental College.

    Science.gov (United States)

    Spiritoso, Stephen; Gross, Erin; Bean, Canise Y; Casamassimo, Paul S; Levings, Kevin; Lloyd, Patrick

    2015-08-01

    The aim of this study was to investigate the contribution of a tiered predoctoral pediatric dentistry clinical education model to competency achievement by dental students over a two-year clinical education. Retrospective data were obtained for academic years 2012-13 and 2013-14 from three sources: a campus-based, dental school-housed clinic; division-directed clinics in community-based pediatric and special needs clinics (DDC); and clinics affiliated with the dental college's community-based dental education (CBDE) program, the OHIO Project (OP). A fourth dataset was obtained for the same two-year period from a biannual clinic event held at the college in conjunction with Give Kids a Smile Day (GKAS). Procedures considered essential to the care of children were sorted by 12 dental codes from all services for patients 18 years of age and younger. The dental school clinic provided 11,060 procedures; the DDC, 28,462; the OP, 17,863; and GKAS, 2,028. The two-year total was 59,433 procedures. Numbers of diagnostic and preventive procedures were 19,441, restorative procedures were 13,958, and pulp and surgical procedures were 7,392. Site contribution ranged from 52.2 to 144.9 procedures per attending student, with the DDC yielding the highest per student average for each year (126.4 and 144.9) and the dental school clinic the lowest (52.2 and 53.1). This study found that a combination of school-based, community-based, and philanthropic pediatric dental experiences offered a large number of essential pediatric dentistry experiences for predoctoral dental students, with CBDE opportunities offering the largest contribution.

  5. Panoramic dental radiography

    International Nuclear Information System (INIS)

    Cushman, R.H.; Kircher, D.R.; Hart, F.W.; Ciavattoni, A.

    1980-01-01

    Apparatus is described for improving the handling rate of patients in panoramic dental radiography when tube head-camera assembly of a low silhouette panoramic dental X-ray machine is rotated for a scan in one direction only. This is effected by fast return of the tube head-camera assembly with its simultaneous elevation, thus facilitating the radiographed patient's exit from the machine and the entrance of another patient. Fast speed is about twice the scanning speed. (author)

  6. Buoyancy-activated cell sorting using targeted biotinylated albumin microbubbles.

    Directory of Open Access Journals (Sweden)

    Yu-Ren Liou

    Full Text Available Cell analysis often requires the isolation of certain cell types. Various isolation methods have been applied to cell sorting, including fluorescence-activated cell sorting and magnetic-activated cell sorting. However, these conventional approaches involve exerting mechanical forces on the cells, thus risking cell damage. In this study we applied a novel isolation method called buoyancy-activated cell sorting, which involves using biotinylated albumin microbubbles (biotin-MBs conjugated with antibodies (i.e., targeted biotin-MBs. Albumin MBs are widely used as contrast agents in ultrasound imaging due to their good biocompatibility and stability. For conjugating antibodies, biotin is conjugated onto the albumin MB shell via covalent bonds and the biotinylated antibodies are conjugated using an avidin-biotin system. The albumin microbubbles had a mean diameter of 2 μm with a polydispersity index of 0.16. For cell separation, the MDA-MB-231 cells are incubated with the targeted biotin-MBs conjugated with anti-CD44 for 10 min, centrifuged at 10 g for 1 min, and then allowed 1 hour at 4 °C for separation. The results indicate that targeted biotin-MBs conjugated with anti-CD44 antibodies can be used to separate MDA-MB-231 breast cancer cells; more than 90% of the cells were collected in the MB layer when the ratio of the MBs to cells was higher than 70:1. Furthermore, we found that the separating efficiency was higher for targeted biotin-MBs than for targeted avidin-incorporated albumin MBs (avidin-MBs, which is the most common way to make targeted albumin MBs. We also demonstrated that the recovery rate of targeted biotin-MBs was up to 88% and the sorting purity was higher than 84% for a a heterogenous cell population containing MDA-MB-231 cells (CD44(+ and MDA-MB-453 cells (CD44-, which are classified as basal-like breast cancer cells and luminal breast cancer cells, respectively. Knowing that the CD44(+ is a commonly used cancer

  7. Saliva and dental erosion

    Directory of Open Access Journals (Sweden)

    Marília Afonso Rabelo Buzalaf

    2012-10-01

    Full Text Available Dental erosion is a multifactorial condition. The consideration of chemical, biological and behavioral factors is fundamental for its prevention and therapy. Among the biological factors, saliva is one of the most important parameters in the protection against erosive wear. Objective: This review discusses the role of salivary factors on the development of dental erosion. Material and Methods: A search was undertaken on MeDLINe website for papers from 1969 to 2010. The keywords used in the research were "saliva", "acquired pellicle", "salivary flow", "salivary buffering capacity" and "dental erosion". Inclusion of studies, data extraction and quality assessment were undertaken independently and in duplicate by two members of the review team. Disagreements were solved by discussion and consensus or by a third party. Results: Several characteristics and properties of saliva play an important role in dental erosion. Salivary clearance gradually eliminates the acids through swallowing and saliva presents buffering capacity causing neutralization and buffering of dietary acids. Salivary flow allows dilution of the acids. In addition, saliva is supersaturated with respect to tooth mineral, providing calcium, phosphate and fluoride necessary for remineralization after an erosive challenge. Furthermore, many proteins present in saliva and acquired pellicle play an important role in dental erosion. Conclusions: Saliva is the most important biological factor affecting the progression of dental erosion. Knowledge of its components and properties involved in this protective role can drive the development of preventive measures targeting to enhance its known beneficial effects.

  8. Saliva and dental erosion.

    Science.gov (United States)

    Buzalaf, Marília Afonso Rabelo; Hannas, Angélicas Reis; Kato, Melissa Thiemi

    2012-01-01

    Dental erosion is a multifactorial condition. The consideration of chemical, biological and behavioral factors is fundamental for its prevention and therapy. Among the biological factors, saliva is one of the most important parameters in the protection against erosive wear. This review discusses the role of salivary factors on the development of dental erosion. A search was undertaken on MeDLINe website for papers from 1969 to 2010. The keywords used in the research were "saliva", "acquired pellicle", "salivary flow", "salivary buffering capacity" and "dental erosion". Inclusion of studies, data extraction and quality assessment were undertaken independently and in duplicate by two members of the review team. Disagreements were solved by discussion and consensus or by a third party. Several characteristics and properties of saliva play an important role in dental erosion. Salivary clearance gradually eliminates the acids through swallowing and saliva presents buffering capacity causing neutralization and buffering of dietary acids. Salivary flow allows dilution of the acids. In addition, saliva is supersaturated with respect to tooth mineral, providing calcium, phosphate and fluoride necessary for remineralization after an erosive challenge. Furthermore, many proteins present in saliva and acquired pellicle play an important role in dental erosion. Saliva is the most important biological factor affecting the progression of dental erosion. Knowledge of its components and properties involved in this protective role can drive the development of preventive measures targeting to enhance its known beneficial effects.

  9. Managing dental erosion.

    Science.gov (United States)

    Curtis, Donald A; Jayanetti, Jay; Chu, Raymond; Staninec, Michal

    2012-01-01

    The clinical signs of dental erosion are initially subtle, yet often progress because the patient remains asymptomatic, unaware and uninformed. Erosion typically works synergistically with abrasion and attrition to cause loss of tooth structure, making diagnosis and management complex. The purpose of this article is to outline clinical examples of patients with dental erosion that highlight the strategy of early identification, patient education and conservative restorative management. Dental erosion is defined as the pathologic chronic loss of dental hard tissues as a result of the chemical influence of exogenous or endogenous acids without bacterial involvement. Like caries or periodontal disease, erosion has a multifactorial etiology and requires a thorough history and examination for diagnosis. It also requires patient understanding and compliance for improved outcomes. Erosion can affect the loss of tooth structure in isolation of other cofactors, but most often works in synergy with abrasion and attrition in the loss of tooth structure (Table 1). Although erosion is thought to be an underlying etiology of dentin sensitivity, erosion and loss of tooth structure often occurs with few symptoms. The purpose of this article is threefold: first, to outline existing barriers that may limit early management of dental erosion. Second, to review the clinical assessment required to establish a diagnosis of erosion. And third, to outline clinical examples that review options to restore lost tooth structure. The authors have included illustrations they hope will be used to improve patient understanding and motivation in the early management of dental erosion.

  10. Recent Advances in Material and Geometrical Modelling in Dental Applications

    Directory of Open Access Journals (Sweden)

    Waleed M. S. Al Qahtani

    2018-06-01

    Full Text Available This article touched, in brief, the recent advances in dental materials and geometric modelling in dental applications. Most common categories of dental materials as metallic alloys, composites, ceramics and nanomaterials were briefly demonstrated. Nanotechnology improved the quality of dental biomaterials. This new technology improves many existing materials properties, also, to introduce new materials with superior properties that covered a wide range of applications in dentistry. Geometric modelling was discussed as a concept and examples within this article. The geometric modelling with engineering Computer-Aided-Design (CAD system(s is highly satisfactory for further analysis or Computer-Aided-Manufacturing (CAM processes. The geometric modelling extracted from Computed-Tomography (CT images (or its similar techniques for the sake of CAM also reached a sufficient level of accuracy, while, obtaining efficient solid modelling without huge efforts on body surfaces, faces, and gaps healing is still doubtable. This article is merely a compilation of knowledge learned from lectures, workshops, books, and journal articles, articles from the internet, dental forum, and scientific groups' discussions.

  11. American Academy of Dental Sleep Medicine

    Science.gov (United States)

    ... New Research AADSM Highlights Members More news... Dental Sleep Medicine: An area of dental practice that focuses on ... SomnoMed Silver Sponsors Copyright © American Academy of Dental Sleep Medicine, All Rights Reserved. American Academy of Dental Sleep ...

  12. Dental patients' use of the Internet.

    LENUS (Irish Health Repository)

    2009-12-19

    To determine the use of the Internet by patients attending a range of dental clinics to search for information regarding dental procedures, and also to investigate their interest in online dental consultations and \\'dental tourism\\'.

  13. 42 CFR Appendix G to Part 75 - Standards for Licensing Dental Hygienists and Dental Assistants in Dental Radiography

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Standards for Licensing Dental Hygienists and Dental Assistants in Dental Radiography G Appendix G to Part 75 Public Health PUBLIC HEALTH SERVICE...—Standards for Licensing Dental Hygienists and Dental Assistants in Dental Radiography The following section...

  14. An Automated Sorting System Based on Virtual Instrumentation Techniques

    Directory of Open Access Journals (Sweden)

    Rodica Holonec

    2008-07-01

    Full Text Available The application presented in this paper represents an experimental model and it refers to the implementing of an automated sorting system for pieces of same shape but different sizes and/or colors. The classification is made according to two features: the color and weight of these pieces. The system is a complex combination of NI Vision hardware and software tools, strain gauges transducers, signal conditioning connected to data acquisition boards, motion and control elements. The system is very useful for students to learn and experiment different virtual instrumentation techniques in order to be able to develop a large field of applications from inspection and process control to sorting and assembly

  15. Oscillating microbubbles for selective particle sorting in acoustic microfluidic devices

    Science.gov (United States)

    Rogers, Priscilla; Xu, Lin; Neild, Adrian

    2012-05-01

    In this study, acoustic waves were used to excite a microbubble for selective particle trapping and sorting. Excitation of the bubble at its volume resonance, as necessary to drive strong fluid microstreaming, resulted in the particles being either selectively attracted to the bubble or continuing to follow the local microstreamlines. The operating principle exploited two acoustic phenomena acting on the particle suspension: the drag force arising from the acoustic microstreaming and the secondary Bjerknes force, i.e. the attractive radiation force produced between an oscillating bubble and a non-buoyant particle. It was also found that standing wave fields within the fluid chamber could be used to globally align bubbles and particles for local particle sorting by the bubble.

  16. Past, present and future of spike sorting techniques.

    Science.gov (United States)

    Rey, Hernan Gonzalo; Pedreira, Carlos; Quian Quiroga, Rodrigo

    2015-10-01

    Spike sorting is a crucial step to extract information from extracellular recordings. With new recording opportunities provided by the development of new electrodes that allow monitoring hundreds of neurons simultaneously, the scenario for the new generation of algorithms is both exciting and challenging. However, this will require a new approach to the problem and the development of a common reference framework to quickly assess the performance of new algorithms. In this work, we review the basic concepts of spike sorting, including the requirements for different applications, together with the problems faced by presently available algorithms. We conclude by proposing a roadmap stressing the crucial points to be addressed to support the neuroscientific research of the near future. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  17. A 1.375-approximation algorithm for sorting by transpositions.

    Science.gov (United States)

    Elias, Isaac; Hartman, Tzvika

    2006-01-01

    Sorting permutations by transpositions is an important problem in genome rearrangements. A transposition is a rearrangement operation in which a segment is cut out of the permutation and pasted in a different location. The complexity of this problem is still open and it has been a 10-year-old open problem to improve the best known 1.5-approximation algorithm. In this paper, we provide a 1.375-approximation algorithm for sorting by transpositions. The algorithm is based on a new upper bound on the diameter of 3-permutations. In addition, we present some new results regarding the transposition diameter: we improve the lower bound for the transposition diameter of the symmetric group and determine the exact transposition diameter of simple permutations.

  18. Comparison of spike-sorting algorithms for future hardware implementation.

    Science.gov (United States)

    Gibson, Sarah; Judy, Jack W; Markovic, Dejan

    2008-01-01

    Applications such as brain-machine interfaces require hardware spike sorting in order to (1) obtain single-unit activity and (2) perform data reduction for wireless transmission of data. Such systems must be low-power, low-area, high-accuracy, automatic, and able to operate in real time. Several detection and feature extraction algorithms for spike sorting are described briefly and evaluated in terms of accuracy versus computational complexity. The nonlinear energy operator method is chosen as the optimal spike detection algorithm, being most robust over noise and relatively simple. The discrete derivatives method [1] is chosen as the optimal feature extraction method, maintaining high accuracy across SNRs with a complexity orders of magnitude less than that of traditional methods such as PCA.

  19. Spatial sorting promotes the spread of maladaptive hybridization

    Science.gov (United States)

    Lowe, Winsor H.; Muhlfeld, Clint C.; Allendorf, Fred W.

    2015-01-01

    Invasive hybridization is causing loss of biodiversity worldwide. The spread of such introgression can occur even when hybrids have reduced Darwinian fitness, which decreases the frequency of hybrids due to low survival or reproduction through time. This paradox can be partially explained by spatial sorting, where genotypes associated with dispersal increase in frequency at the edge of expansion, fueling further expansion and allowing invasive hybrids to increase in frequency through space rather than time. Furthermore, because all progeny of a hybrid will be hybrids (i.e., will possess genes from both parental taxa), nonnative admixture in invaded populations can increase even when most hybrid progeny do not survive. Broader understanding of spatial sorting is needed to protect native biodiversity.

  20. System Architecture For High Speed Sorting Of Potatoes

    Science.gov (United States)

    Marchant, J. A.; Onyango, C. M.; Street, M. J.

    1989-03-01

    This paper illustrates an industrial application of vision processing in which potatoes are sorted according to their size and shape at speeds of up to 40 objects per second. The result is a multi-processing approach built around the VME bus. A hardware unit has been designed and constructed to encode the boundary of the potatoes, to reducing the amount of data to be processed. A master 68000 processor is used to control this unit and to handle data transfers along the bus. Boundary data is passed to one of three 68010 slave processors each responsible for a line of potatoes across a conveyor belt. The slave processors calculate attributes such as shape, size and estimated weight of each potato and the master processor uses this data to operate the sorting mechanism. The system has been interfaced with a commercial grading machine and performance trials are now in progress.