WorldWideScience

Sample records for density measuring system

  1. Mammographic density measurements are not affected by mammography system.

    Science.gov (United States)

    Damases, Christine N; Brennan, Patrick C; McEntee, Mark F

    2015-01-01

    Mammographic density (MD) is a significant risk factor for breast cancer and has been shown to reduce the sensitivity of mammography screening. Knowledge of a woman's density can be used to predict her risk of developing breast cancer and personalize her imaging pathway. However, measurement of breast density has proven to be troublesome with wide variations in density recorded using radiologists' visual Breast Imaging Reporting and Data System (BIRADS). Several automated methods for assessing breast density have been proposed, each with their own source of measurement error. The use of differing mammographic imaging systems further complicates MD measurement, especially for the same women imaged over time. The purpose of this study was to investigate whether having a mammogram on differing manufacturer's equipment affects a woman's MD measurement. Raw mammographic images were acquired on two mammography imaging systems (General Electric and Hologic) one year apart and processed using VolparaDensity™ to obtain the Volpara Density Grade (VDG) and average volumetric breast density percentage (AvBD%). Visual BIRADS scores were also obtained from 20 expert readers. BIRADS scores for both systems showed strong positive correlation ([Formula: see text]; [Formula: see text]), while the VDG ([Formula: see text]; [Formula: see text]) and AvBD% ([Formula: see text]; [Formula: see text]) showed stronger positive correlations. Substantial agreement was shown between the systems for BIRADS ([Formula: see text]; [Formula: see text]), however, the systems demonstrated an almost perfect agreement for VDG ([Formula: see text]; [Formula: see text]).

  2. A magnetic suspension system for measuring liquid density

    Directory of Open Access Journals (Sweden)

    Luz María Centeno González

    2013-04-01

    Full Text Available Density is a derived quantity of mass and length; it is defined as mass per volume unit and its SI unit is kg/m3. National metrology institutes have been designing and building their own magnetic suspension systems during the last 5 decades for making fluid density measurements; this has allowed them to carry out research into liquids and gases’ physical characteristics. This paper was aimed at designing and developing a magnetic suspension system for a magnetic balance used in determining liquid density to be used in CENAM’s metrology density laboratories.

  3. WSN-Based Space Charge Density Measurement System.

    Science.gov (United States)

    Deng, Dawei; Yuan, Haiwen; Lv, Jianxun; Ju, Yong

    2017-01-01

    It is generally acknowledged that high voltage direct current (HVDC) transmission line endures the drawback of large area, because of which the utilization of cable for space charge density monitoring system is of inconvenience. Compared with the traditional communication network, wireless sensor network (WSN) shows advantages in small volume, high flexibility and strong self-organization, thereby presenting great potential in solving the problem. Additionally, WSN is more suitable for the construction of distributed space charge density monitoring system as it has longer distance and higher mobility. A distributed wireless system is designed for collecting and monitoring the space charge density under HVDC transmission lines, which has been widely applied in both Chinese state grid HVDC test base and power transmission projects. Experimental results of the measuring system demonstrated its adaptability in the complex electromagnetic environment under the transmission lines and the ability in realizing accurate, flexible, and stable demands for the measurement of space charge density.

  4. The impact of mammographic imaging systems on density measurement

    Science.gov (United States)

    Damases, Christine N.; Brennan, Patrick C.; McEntee, Mark F.

    2015-03-01

    The purpose of this study is to investigate whether having a mammogram on differing manufacturer equipment will affect a woman's breast density (BD) measurement. The data set comprised of 40 cases, each containing a combined image of the left craniocaudal (LCC) and left mediolateral oblique (LMLO). These images were obtained from 20 women age between 42-89 years. The images were acquired on two imaging systems (GE and Hologic) one year apart. Volumetric BD was assessed by using Volpara Density Grade (VDG) and average BD% (AvBD%). Twenty American Board of Radiology (ABR) examiners assessed the same images using the BIRADS BD scale 1-4. Statistical comparisons were performed on the means using Mann-Whitney, on correlation using Spearman's rank coefficient of correlation and agreement using Cohen's Kappa. The absolute median BIRADS difference between GE and Hologic was 0.225 (2.00 versus 2.00; pBIRADS for GE and Hologic systems showed strong positive correlation (ρ=0.904; pBIRADS density shown with Cohen's Kappa (κ=0.692; p<0.001), however the systems demonstrated an almost perfect agreement for VDG (κ=0.933; p<0.001).

  5. Direct Measurement of the Density Matrix of a Quantum System

    Science.gov (United States)

    Thekkadath, G. S.; Giner, L.; Chalich, Y.; Horton, M. J.; Banker, J.; Lundeen, J. S.

    2016-09-01

    One drawback of conventional quantum state tomography is that it does not readily provide access to single density matrix elements since it requires a global reconstruction. Here, we experimentally demonstrate a scheme that can be used to directly measure individual density matrix elements of general quantum states. The scheme relies on measuring a sequence of three observables, each complementary to the last. The first two measurements are made weak to minimize the disturbance they cause to the state, while the final measurement is strong. We perform this joint measurement on polarized photons in pure and mixed states to directly measure their density matrix. The weak measurements are achieved using two walk-off crystals, each inducing a polarization-dependent spatial shift that couples the spatial and polarization degrees of freedom of the photons. This direct measurement method provides an operational meaning to the density matrix and promises to be especially useful for large dimensional states.

  6. Optical density measurements in a multiphase cryogenic fluid flow system

    Science.gov (United States)

    Korman, Valentin; Wiley, John; Gregory, Don A.

    2006-05-01

    An accurate determination of fluid flow in a cryogenic propulsion environment is difficult under the best of circumstances. The extreme thermal environment increases the mechanical constraints, and variable density conditions create havoc with traditional flow measurement schemes. Presented here are secondary results of cryogenic testing of an all-optical sensor capable of a mass flow measurement by directly interrogating the fluid's density state and a determination of the fluid's velocity. The sensor's measurement basis does not rely on any inherent assumptions as to the state of the fluid flow (density or otherwise). The fluid sensing interaction model will be discussed. Current test and evaluation data and future development work will be presented.

  7. Calibration system for measuring the radon flux density.

    Science.gov (United States)

    Onishchenko, A; Zhukovsky, M; Bastrikov, V

    2015-06-01

    The measurement of radon flux from soil surface is the useful tool for the assessment of radon-prone areas and monitoring of radon releases from uranium mining and milling residues. The accumulation chambers with hollow headspace and chambers with activated charcoal are the most used devices for these purposes. Systematic errors of the measurements strongly depend on the geometry of the chamber and diffusion coefficient of the radon in soil. The calibration system for the attestation of devices for radon flux measurements was constructed. The calibration measurements of accumulation chambers and chambers with activated charcoal were conducted. The good agreement between the results of 2D modelling of radon flux and measurements results was observed. It was demonstrated that reliable measurements of radon flux can be obtained by chambers with activated charcoal (equivalent volume ~75 l) or by accumulation chambers with hollow headspace of ~7-10 l and volume/surface ratio (height) of >15 cm.

  8. Density Measurement System for Weights of 1 kg to 20 kg Using Hydrostatic Weighing

    Science.gov (United States)

    Lee, Yong Jae; Lee, Woo Gab; Abdurahman, Mohammed; Kim, Kwang Pyo

    This paper presents a density measurement system to determine density of weights from 1 kg to 20 kg using hydrostatic weighing. The system works based on Archimedes principle. The density of reference liquid is determined using this setup while determining the density of the test weight. Density sphere is used as standard density ball to determine density of the reference liquid. A new immersion pan is designed for dual purpose to carry the density sphere and the cylindrical test weight for weighing in liquid. Main parts of the setup are an electronic balance, a thermostat controlled liquid bath, reference weights designed for bottom weighing, dual purpose immersion pans and stepping motors to load and unload in weighing process. The results of density measurement will be evaluated as uncertainties for weights of 1 kg to 20 kg.

  9. Density measurements under pressure for the binary system (ethanol plus methylcyclohexane)

    DEFF Research Database (Denmark)

    Zeberg-Mikkelsen, Claus Kjær; Lugo, L.; Fernandez, J.

    2005-01-01

    The density of the asymmetrical binary system composed of ethanol and methylcyclohexane has been measured under pressure using a vibrating tube densimeter. The measurements have been performed for eight different compositions as well as the pure compounds at eight temperatures in the range 283.15...

  10. High-pressure density measurements for the binary system ethanol plus heptane

    DEFF Research Database (Denmark)

    Watson, G.; Zeberg-Mikkelsen, Claus Kjær; Baylaucq, A.

    2006-01-01

    The density of the asymmetrical binary system composed of ethanol and heptane has been measured (630 points) for nine different compositions including the pure compounds at five temperatures in the range (293.15 to 333.15) K and 14 isobars up to 65 MPa with a vibrating-tube densimeter, The experi......The density of the asymmetrical binary system composed of ethanol and heptane has been measured (630 points) for nine different compositions including the pure compounds at five temperatures in the range (293.15 to 333.15) K and 14 isobars up to 65 MPa with a vibrating-tube densimeter...

  11. Faraday-effect polarimeter-interferometer system for current density measurement on EAST.

    Science.gov (United States)

    Liu, H Q; Jie, Y X; Ding, W X; Brower, D L; Zou, Z Y; Li, W M; Wang, Z X; Qian, J P; Yang, Y; Zeng, L; Lan, T; Wei, X C; Li, G S; Hu, L Q; Wan, B N

    2014-11-01

    A multichannel far-infrared laser-based POlarimeter-INTerferometer (POINT) system utilizing the three-wave technique is under development for current density and electron density profile measurements in the EAST tokamak. Novel molybdenum retro-reflectors are mounted in the inside wall for the double-pass optical arrangement. A Digital Phase Detector with 250 kHz bandwidth, which will provide real-time Faraday rotation angle and density phase shift output, have been developed for use on the POINT system. Initial calibration indicates the electron line-integrated density resolution is less than 5 × 10(16) m(-2) (∼2°), and the Faraday rotation angle rms phase noise is <0.1°.

  12. MEASUREMENT OF WHEAT DENSITY

    Institute of Scientific and Technical Information of China (English)

    冯跟胜; 党金春; 等

    1995-01-01

    A method used for on line determining the change of wheat density with a automatic watering machine in a lqarge flour mill has been studied.The results show that the higher distinguishing ability is obtained when using 241Am as a γ-ray source for measuring the wheat density than using 137Cs.

  13. A high-resolution optical measurement system for rapid acquisition of radiation flux density maps

    Science.gov (United States)

    Thelen, Martin; Raeder, Christian; Willsch, Christian; Dibowski, Gerd

    2017-06-01

    To identify the power and flux density of concentrated solar radiation the Institute of Solar Research at the German Aerospace Center (DLR - Deutsches Zentrum für Luft-und Raumfahrt e. V.) has used the camera-based measurement system FATMES (Flux and Temperature Measurement System) since 1995. The disadvantages of low resolution, difficult handling and poor computing power required a revision of the existing measurement system. The measurement system FMAS (Flux Mapping Acquisition system) is equipped with state-of-the-art-hardware, is compatible with computers off-the-shelf and is programmed in LabView. The expenditure of time for an image evaluation is reduced by the factor 60 compared to FATMES. The new measurement system is no longer associated with the facilities Solar Furnace and High Flux Solar Simulator at the DLR in Cologne but is also applicable as a mobile system. The data and the algorithms are transparent throughout the complete process. The measurement accuracy of FMAS is determined to at most ±3 % until now. The error of measurement of FATMES is at least 2 % higher according to the conducted comparison tests.

  14. Simultaneous Microwave Imaging System for Density and Temperature Fluctuation Measurements on TEXTOR

    Energy Technology Data Exchange (ETDEWEB)

    H. Park; E. Mazzucato; T. Munsat; C.W. Domier; M. Johnson; N.C. Luhmann, Jr.; J. Wang; Z. Xia; I.G.J. Classen; A.J.H. Donne; M.J. van de Pol

    2004-05-07

    Diagnostic systems for fluctuation measurements in plasmas have, of necessity, evolved from simple 1-D systems to multi-dimensional systems due to the complexity of the MHD and turbulence physics of plasmas illustrated by advanced numerical simulations. Using the recent significant advancements in millimeter wave imaging technology, Microwave Imaging Reflectometry (MIR) and Electron Cyclotron Emission Imaging (ECEI), simultaneously measuring density and temperature fluctuations, are developed for TEXTOR. The MIR system was installed on TEXTOR and the first experiment was performed in September, 2003. Subsequent MIR campaigns have yielded poloidally resolved spectra and assessments of poloidal velocity. The new 2-D ECE Imaging system (with a total of 128 channels), installed on TEXTOR in December, 2003, successfully captured a true 2-D images of Te fluctuations of m=1 oscillation (''sawteeth'') near the q {approx} 1 surface for the first time.

  15. Density measurements under pressure for the binary system 1-propanol plus toluene

    DEFF Research Database (Denmark)

    Zeberg-Mikkelsen, Claus Kjær; Andersen, Simon Ivar

    2005-01-01

    The density of the binary system composed of 1-propanol and toluene has been measured under pressure using a vibrating-tube densimeter. The measurements have been performed for four different compositions as well as the pure compounds at four temperatures in the range of (303.15 to 333.15) K and ...... but also due to the electron donor- acceptor-type formation of hydrogen bonding between the hydroxyl group of 1-propanol and the pi electrons of toluene because aromatic hydrocarbons can act as electron donors....

  16. Measurements and predictions of the air distribution systems in high compute density (Internet) data centers

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jinkyun [HIMEC (Hanil Mechanical Electrical Consultants) Ltd., Seoul 150-103 (Korea); Department of Architectural Engineering, Yonsei University, Seoul 120-749 (Korea); Lim, Taesub; Kim, Byungseon Sean [Department of Architectural Engineering, Yonsei University, Seoul 120-749 (Korea)

    2009-10-15

    When equipment power density increases, a critical goal of a data center cooling system is to separate the equipment exhaust air from the equipment intake air in order to prevent the IT server from overheating. Cooling systems for data centers are primarily differentiated according to the way they distribute air. The six combinations of flooded and locally ducted air distribution make up the vast majority of all installations, except fully ducted air distribution methods. Once the air distribution system (ADS) is selected, there are other elements that must be integrated into the system design. In this research, the design parameters and IT environmental aspects of the cooling system were studied with a high heat density data center. CFD simulation analysis was carried out in order to compare the heat removal efficiencies of various air distribution systems. The IT environment of an actual operating data center is measured to validate a model for predicting the effect of different air distribution systems. A method for planning and design of the appropriate air distribution system is described. IT professionals versed in precision air distribution mechanisms, components, and configurations can work more effectively with mechanical engineers to ensure the specification and design of optimized cooling solutions. (author)

  17. Measurement of the optical density of packable composites: comparison between direct and indirect digital systems

    Directory of Open Access Journals (Sweden)

    Graziottin Luiz Felipe Rodrigues

    2002-01-01

    Full Text Available The aim of this study was to measure the optical density of four packable composite resins with widths of 1, 2, 3 and 4 mm, by means of Digora® (direct and DentScan DentView® (indirect digital imaging systems, in order to compare both methods. Twenty acrylic plates, with the proposed thicknesses, were used, each one containing a sample of each resin. Each acrylic plate was radiographed three times, under a standardized technique. For the Digora® system, an optical plate was used under each resin sample, and, for the DentScan DentView® system, occlusal films were employed, totalizing 60 exposures for each system. Optical plates and films were scanned and three consecutive optical readouts were carried out, totalizing 1,440 readouts. The results were submitted to statistical analysis and revealed that the average optical density of the four resins always increased as thickness increased. Regarding the comparisons between the composite resins, in both analysis the resin with the greater optical density was SurefilTM followed by ProdigyTM Condensable, AlertTM and Solitaire®. The correlations between the results of Digora® and DentScan DentView® were significant for the different thicknesses and materials. The observed tendency is that as the values obtained with the Digora® system increase, so do the values obtained with DentScan DentView®. While thickness increased, the values of optical density in both Digora® and DentScan DentView® tended to approach each other. The Digora® system presented smaller amplitude between the results obtained in adjacent thicknesses.

  18. Data-driven sensitivity inference for Thomson scattering electron density measurement systems

    Science.gov (United States)

    Fujii, Keisuke; Yamada, Ichihiro; Hasuo, Masahiro

    2017-01-01

    We developed a method to infer the calibration parameters of multichannel measurement systems, such as channel variations of sensitivity and noise amplitude, from experimental data. We regard such uncertainties of the calibration parameters as dependent noise. The statistical properties of the dependent noise and that of the latent functions were modeled and implemented in the Gaussian process kernel. Based on their statistical difference, both parameters were inferred from the data. We applied this method to the electron density measurement system by Thomson scattering for the Large Helical Device plasma, which is equipped with 141 spatial channels. Based on the 210 sets of experimental data, we evaluated the correction factor of the sensitivity and noise amplitude for each channel. The correction factor varies by ≈10%, and the random noise amplitude is ≈2%, i.e., the measurement accuracy increases by a factor of 5 after this sensitivity correction. The certainty improvement in the spatial derivative inference was demonstrated.

  19. Mobile lidar system for measurement of water vapor mixing ratio and ozone number density

    Science.gov (United States)

    Whiteman, D.

    1988-01-01

    The Water Vapor Lidar was modified and extended to make differential absorption measurements of ozone. Water vapor measurements make use of a weak molecular scattering process known as Raman scattering. It is characterized by a shift in wavelength of the scattered beam of light relative to the incident one. Some of the energy of the incident photon is converted to vibrational or rotational energy within the molecule leaving the scattered photon shifted to a slightly longer wavelength. When performing water vapor measurements, profiles are acquired of water vapor mixing ratio from near the ground to beyond 7 km every 2 minutes. By forming a color composite image of the individual profiles, the spatial and temporal evolution of water vapor is visible with vertical resolution of 75 to 150m and temporal resolution of 2 minutes. The ozone lidar is intended for use as a cross calibration facility for other stationary ozone lidar systems. The ozone measurement employs the technique known as differential absorption. The backscattered laser radiation from two different wavelengths is measured. Successful measurements of 308 nm returns were made from 80 km with an averaging period of 6 hours. Using these data and a standard atmosphere density curve, an ozone number density profile was made which agrees very well with the standard ozone curve between 20 and 40 km.

  20. Application of microwave imaging system for density fluctuation measurements on Large Helical Device

    Energy Technology Data Exchange (ETDEWEB)

    Pavlichenko, R.; Nagayama, Y.; Kawahata, K. [National Institute for Fusion Science (NIFS), Toki (Japan); Ignatenko, M.; Kogi, Y.; Mase, A. [Kyushu Univ., KASTEC, Kasuga (Japan)

    2004-07-01

    This short paper describes the microwave imaging reflectometry system that has been installed on the Large Helical Device as a plasma diagnostic system for spatially resolved plasma density fluctuations.

  1. Density measures and additive property

    OpenAIRE

    Kunisada, Ryoichi

    2015-01-01

    We deal with finitely additive measures defined on all subsets of natural numbers which extend the asymptotic density (density measures). We consider a class of density measures which are constructed from free ultrafilters on natural numbers and study a certain additivity property of such density measures.

  2. Density measures and additive property

    OpenAIRE

    Kunisada, Ryoichi

    2015-01-01

    We deal with finitely additive measures defined on all subsets of natural numbers which extend the asymptotic density (density measures). We consider a class of density measures which are constructed from free ultrafilters on natural numbers and study a certain additivity property of such density measures.

  3. Hypothesis tests for large density matrices of quantum systems based on Pauli measurements

    Science.gov (United States)

    Kim, Donggyu; Wang, Yazhen

    2017-03-01

    For a quantum system, its density matrix usually has a size growing exponentially with the number of particles in the system, and quantum state tomography techniques often encounter an exponential complexity problem for recovering the density matrix based on experimental data. Recent statistical methods for estimating a large density matrix have been developed for the cases that (i) the entries of the density matrix with respect to the Pauli basis are sparse, or (ii) the density matrix has a low rank, and its eigenvectors are sparse. Their performances depend on the assumed structures, and it is important to test for the structures and choose appropriate estimation methods accordingly. This paper investigates hypothesis tests for sparsity. Specifically, we propose hypothesis test procedures and establish asymptotic theories for the proposed tests. Numerical studies are conducted to check the finite sample performances of the proposed hypothesis tests.

  4. Radiodensitometric and DXA analyses for the measurement of bone mineral density after systemic alendronate therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lucisano, Marilia Pacifico; Nelson-Filho, Paulo; Silva, Raquel Assed Bezerra da; Silva, Lea Assed Bezerra da, E-mail: nelson@forp.usp.br [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Fac. de Odontologia. Dept. de Clinica Pediatrica, Preventiva e Odontologia Comunitaria; Morse, Leslie [Department of Physical Medicine and Rehabilitation, School of Medicine, Harvard Univ., Boston, MA (United States); Battaglino, Ricardo [Department of Skeletal Biology, Forsyth Institute, Cambridge, MA (United States); Watanabe, Plauto Christopher Aranha [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Fac. de Odontologia. Dept. de Morfologia, Estomacologia e Fisiologia

    2013-05-15

    Precise techniques for the measurement of maxillary bone mineral density (BMD) are useful for the early diagnosis of systemic diseases. The aim of this study was to compare in vivo the efficacy of dual energy x-ray absorptiometry (DXA) and radiographic densitometry for the measurement of BMD after systemic administration of sodium alendronate. Wistar rats were randomly allocated to a control group (n = 5), which received distilled water, and a sodium alendronate group (n = 8), which received two doses of chemically pure sodium alendronate (1 mg/kg) per week. After 8 weeks, the animals were euthanized, the tibias were removed, and the BMD of the proximal tibial metaphysis was analyzed radiographically and by DXA. The data were subjected to statistical analysis by the Kruskal-Wallis test at a significance level of 5%. Both of the techniques revealed that the alendronate-treated group had a significantly higher BMD (p < 0.05) than the control group after 8 weeks of treatment. Comparing the groups with and without alendronate therapy revealed increases of 14.9% and 29.6% in BMD, as detected radiographically and by DXA, respectively. In conclusion, both of the methods were able to detect an increase in BMD of the proximal tibial metaphysis after alendronate therapy. (author)

  5. Development of KSTAR ECE imaging system for measurement of temperature fluctuations and edge density fluctuationsa)

    Science.gov (United States)

    Yun, G. S.; Lee, W.; Choi, M. J.; Kim, J. B.; Park, H. K.; Domier, C. W.; Tobias, B.; Liang, T.; Kong, X.; Luhmann, N. C.; Donné, A. J. H.

    2010-10-01

    The ECE imaging (ECEI) diagnostic tested on the TEXTOR tokamak revealed the sawtooth reconnection physics in unprecedented detail, including the first observation of high-field-side crash and collective heat transport [H. K. Park, N. C. Luhmann, Jr., A. J. H. Donné et al., Phys. Rev. Lett. 96, 195003 (2006)]. An improved ECEI system capable of visualizing both high- and low-field sides simultaneously with considerably better spatial coverage has been developed for the KSTAR tokamak in order to capture the full picture of core MHD dynamics. Direct 2D imaging of other MHD phenomena such as tearing modes, edge localized modes, and even Alfvén eigenmodes is expected to be feasible. Use of ECE images of the optically thin edge region to recover 2D electron density changes during L/H mode transitions is also envisioned, providing powerful information about the underlying physics. The influence of density fluctuations on optically thin ECE is discussed.

  6. Measurement of the spatial resolution and the relative density resolution in an industrial cone-beam micro computed tomography system

    Institute of Scientific and Technical Information of China (English)

    WANG Yan-Fang; QUE Jie-Min; CAO Da-Quan; SUN Cui-Li; ZHAO Wei; WEI Cun-Feng; SHI Rong-Jian

    2013-01-01

    The spatial resolution and the relative density resolution are the two most critical indicators in CT system.The method recommended in the ASTM E1695-95 and GJB 5311-2004 is only suitable to the fan-beam CT system.In this paper,for industrial cone-beam micro CT system,we will adopt the edge response function (ERF) created by the step edges of a steel ball to measure the system 3D PSF and MTF.To describe the contrast discrimination function more accurately,we will first propose to extend the two-dimensional measurement region to the three-dimensional space.Our experimental spatial resolution is (55.56±0.56) lp/mm and the relative density resolution is 1% within 300 μm×300 μm×300 μm according to the 3σ rule.

  7. Particle Size, Number Density, And Velocity Measurements In A 2800 K Combustion System

    Science.gov (United States)

    Farmer, W. M.; Schwartz, F. A.; Stallings, E. S.; Belz, R. A.

    1983-10-01

    Particle size and velocity measurements have been obtained in a low-speed (6 to 10 m/s), 2800 K combustor 30 cm in diameter. The measurements were obtained using a particle-sizing interferometer coupled to a 0.5 m spectrometer for background light rejection from radiant particles. Results obtained for the combustion of powdered coke clearly indicate the capabilities of this type of instrument to estimate combustor efficiency as a function of temperature. Comparison of the optically sampled measurements with other sampling techniques shows reasonable agreement.

  8. The opposition effect and its relationship to sediment density in BRDF measurements from the Algodones Sand Dunes System

    Science.gov (United States)

    Ambeau, Brittany; Bachmann, Charles M.; Griffo, Carrie; Harms, Justin; Myers, Emily; Badura, Gregory

    2016-09-01

    Density, particle size distribution, surface moisture, and mineral content are some important geophysical properties that affect the bi-directional reflectance factor (BRF) of particulate media such as sand. According to radiative transfer theory, several of these geophysical properties are known to directly affect the overall level of reflectance, as well as the functional form of the opposition effect, for homogeneous, particulate media.1 Most sands are composite, i.e. non-homogeneous, and do not follow the standard distributions (with approximate analytical solutions) for particle size. Therefore, conventional radiative transfer models need to be modified to account for the complex nature of sand. In this work, we examine the impact of density on the functional form of the opposition effect, and we show that differences in density are expressed in a characteristic way. The measurements are collected using the laboratory and field-deployable Goniometer of the Rochester Institute of Technology-Two (GRIT-T). And, the results are based on sediment samples collected from the Algodones Sand Dunes System in southeastern California during the NASA Algodones Dunes Field Experiment conducted in March 2015.

  9. Mammographic density estimation with automated volumetric breast density measurement.

    Science.gov (United States)

    Ko, Su Yeon; Kim, Eun-Kyung; Kim, Min Jung; Moon, Hee Jung

    2014-01-01

    To compare automated volumetric breast density measurement (VBDM) with radiologists' evaluations based on the Breast Imaging Reporting and Data System (BI-RADS), and to identify the factors associated with technical failure of VBDM. In this study, 1129 women aged 19-82 years who underwent mammography from December 2011 to January 2012 were included. Breast density evaluations by radiologists based on BI-RADS and by VBDM (Volpara Version 1.5.1) were compared. The agreement in interpreting breast density between radiologists and VBDM was determined based on four density grades (D1, D2, D3, and D4) and a binary classification of fatty (D1-2) vs. dense (D3-4) breast using kappa statistics. The association between technical failure of VBDM and patient age, total breast volume, fibroglandular tissue volume, history of partial mastectomy, the frequency of mass > 3 cm, and breast density was analyzed. The agreement between breast density evaluations by radiologists and VBDM was fair (k value = 0.26) when the four density grades (D1/D2/D3/D4) were used and moderate (k value = 0.47) for the binary classification (D1-2/D3-4). Twenty-seven women (2.4%) showed failure of VBDM. Small total breast volume, history of partial mastectomy, and high breast density were significantly associated with technical failure of VBDM (p = 0.001 to 0.015). There is fair or moderate agreement in breast density evaluation between radiologists and VBDM. Technical failure of VBDM may be related to small total breast volume, a history of partial mastectomy, and high breast density.

  10. Mammography density estimation with automated volumetic breast density measurement

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Su Yeon; Kim, Eun Kyung; Kim, Min Jung; Moon, Hee Jung [Dept. of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-06-15

    To compare automated volumetric breast density measurement (VBDM) with radiologists' evaluations based on the Breast Imaging Reporting and Data System (BI-RADS), and to identify the factors associated with technical failure of VBDM. In this study, 1129 women aged 19-82 years who underwent mammography from December 2011 to January 2012 were included. Breast density evaluations by radiologists based on BI-RADS and by VBDM (Volpara Version 1.5.1) were compared. The agreement in interpreting breast density between radiologists and VBDM was determined based on four density grades (D1, D2, D3, and D4) and a binary classification of fatty (D1-2) vs. dense (D3-4) breast using kappa statistics. The association between technical failure of VBDM and patient age, total breast volume, fibroglandular tissue volume, history of partial mastectomy, the frequency of mass > 3 cm, and breast density was analyzed. The agreement between breast density evaluations by radiologists and VBDM was fair (k value = 0.26) when the four density grades (D1/D2/D3/D4) were used and moderate (k value = 0.47) for the binary classification (D1-2/D3-4). Twenty-seven women (2.4%) showed failure of VBDM. Small total breast volume, history of partial mastectomy, and high breast density were significantly associated with technical failure of VBDM (p 0.001 to 0.015). There is fair or moderate agreement in breast density evaluation between radiologists and VBDM. Technical failure of VBDM may be related to small total breast volume, a history of partial mastectomy, and high breast density.

  11. Excess molar volume of the acetonitrile + alcohol systems at 298.15 K. Part I: Density measurements for acetonitrile + methanol, + ethanol systems

    Directory of Open Access Journals (Sweden)

    SLOBODAN P. SERBANOVIC

    2002-09-01

    Full Text Available The excess molar volume VE of the binary liquid systems acetonitrile + methanol and acetonitrile + ethanol has been evaluated from density measurements at 298.15 K and at atmospheric pressure over the entire composition range. A vibrating tube densimeter, type Anton Paar DMA 55, was applied for these measurements. The Redlich–Kister equation was used to fit the experimental VE data.

  12. Georadar Measurements for the Snow Cover Density

    Directory of Open Access Journals (Sweden)

    A. Godio

    2009-01-01

    Full Text Available Ground Probing Radar (GPR devices is adopted for the analysis of thickness and the mechanical properties (density of the snow cover in some test site in Alps, in Northern Italy. The performances of standard radar systems for the snow cover characterisation are analysed, the main aim is to assess the reliability of the method to estimate the snow density, the snowpack thickness and the depth resolution in terms of capability to detect thin layers. The main relationships between the electrical permittivity and the density of the dry-snow are applied to estimate the density vertical profiles inferred by the GPR investigation. The data were calibrated and compared with the results coming from direct measurements of the density and thickness.

  13. Comparing measurements of breast density

    Energy Technology Data Exchange (ETDEWEB)

    Highnam, R [Highnam Associates Limited, Wellington (New Zealand); Jeffreys, M [Massey University, Wellington (New Zealand); McCormack, V [Department of Epidemiology and Population Health, London School of Hygiene and Medicine, London (United Kingdom); Warren, R [Addenbrooke' s Hospital, Cambridge (United Kingdom); Smith, G Davey [Department of Clinical Epidemiology, University of Bristol, Bristol (United Kingdom); Brady, M [Department of Engineering Science, University of Oxford, Oxford (United Kingdom)

    2007-09-21

    Breast density measurements can be made from mammograms using either area-based methods, such as the six category classification (SCC), or volumetric based methods, such as the standard mammogram form (SMF). Previously, we have shown how both types of methods generate breast density estimates which are generally close. In this paper, we switch our attention to the question of why, for certain cases, they provide widely differing estimates. First, we show how the underlying physical models of the breast employed in the methods need to be consistent, and how area-based methods are susceptible to projection effects. We then analyse a set of patients whose mammograms show large differences between their SCC and SMF assessments. More precisely, 12% of 657 patients were found to fall into this category. Of these, 2.7% were attributable to errors either in the SMF segmentation algorithms, human error in SCC categorization or poor image exposure. More importantly, 9.3% of the cases appear to be due to fundamental differences between the area- and volume-based techniques. We conclude by suggesting how we might remove half of those discrepancies by introducing a new categorization of the SMF estimates based on the breast thickness. We note however, that this still leaves 6% of patients with large differences between SMF and SCC estimates. We discuss why it might not be appropriate to assume SMF (or any volume measure) has a similar breast cancer risk prediction capability to SCC.

  14. Compact and high-particle-flux thermal-lithium-beam probe system for measurement of two-dimensional electron density profile.

    Science.gov (United States)

    Shibata, Y; Manabe, T; Kajita, S; Ohno, N; Takagi, M; Tsuchiya, H; Morisaki, T

    2014-09-01

    A compact and high-particle-flux thermal-lithium-beam source for two-dimensional measurement of electron density profiles has been developed. The thermal-lithium-beam oven is heated by a carbon heater. In this system, the maximum particle flux of the thermal lithium beam was ~4 × 10(19) m(-2) s(-1) when the temperature of the thermal-lithium-beam oven was 900 K. The electron density profile was evaluated in the small tokamak device HYBTOK-II. The electron density profile was reconstructed using the thermal-lithium-beam probe data and this profile was consistent with the electron density profile measured with a Langmuir electrostatic probe. We confirm that the developed thermal-lithium-beam probe can be used to measure the two-dimensional electron density profile with high time and spatial resolutions.

  15. Culture systems: embryo density.

    Science.gov (United States)

    Reed, Michael L

    2012-01-01

    Embryo density is defined as the embryo-to-volume ratio achieved during in vitro culture; in other words, it is the number of embryos in a defined volume of culture medium. The same density can be achieved by manipulating either the number of embryos in a given volume of medium, or manipulating the volume of the medium for a given number of embryos: for example, a microdrop with five embryos in a 50 μl volume under oil has the same embryo-to-volume ratio (1:10 μl) as a microdrop with one embryo in a 10 μl volume under oil (1:10 μl). Increased embryo density can improve mammalian embryo development in vitro; however, the mechanism(s) responsible for this effect may be different with respect to which method is used to increase embryo density.Standard, flat sterile plastic petri dishes are the most common, traditional platform for embryo culture. Microdrops under a mineral oil overlay can be prepared to control embryo density, but it is critical that dish preparation is consistent, where appropriate techniques are applied to prevent microdrop dehydration during preparation, and results of any data collection are reliable, and repeatable. There are newer dishes available from several manufacturers that are specifically designed for embryo culture; most are readily available for use with human embryos. The concept behind these newer dishes relies on fabrication of conical and smaller volume wells into the dish design, so that embryos rest at the lowest point in the wells, and where putative embryotrophic factors may concentrate.Embryo density is not usually considered by the embryologist as a technique in and of itself; rather, the decision to culture embryos in groups or individually is protocol-driven, and is based more on convenience or the need to collect data on individual embryos. Embryo density can be controlled, and as such, it can be utilized as a simple, yet effective tool to improve in vitro development of human embryos.

  16. Development of an Analytical System for Determination of Free Acid via a Joint Method Combining Density and Conductivity Measurement

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Determination of free acid plays an important role in spent nuclear fuel reprocessing. It is necessary to develop a rapid analytical device and method for measuring free acid. A novel analytical system and method was studied to monitor the acidity

  17. Density Measurement of Liquid Metals Using Dilatometer

    Institute of Scientific and Technical Information of China (English)

    Lianwen WANG; Qingsong MEI

    2006-01-01

    The dilatometer method for density measurement of liquid metals was improved to give a high measurement accuracy with simple operation. The density of liquid tin was measured and the results are in agreement with values in literature. The melting point density of liquid Sn was measured to be 6.966×103 Kg·m-3 and the temperature (T) dependence of the density (ρ) for liquid Sn can be well described by a polynomial equation ρ(T)=7.406 - 9.94 × 10-4T + 2.12 × 10-7T2.

  18. Welfare of organic laying hens kept at different indoor stocking densities in a multi-tier aviary system. II: live weight, health measures and perching

    DEFF Research Database (Denmark)

    Steenfeldt, Sanna; Nielsen, Birte L.

    2015-01-01

    stocking densities in organic systems within the EU. In this article, results on live weight, health measures and perching are reported for organic laying hens housed in a multi-tier system with permanent access to a veranda and kept at stocking densities (D) of 6, 9 and 12 hens/m2 available floor area...... regulations on the keeping of organic laying hens. Hen live weight, mortality and foot health were not affected by the stocking densities used in the present study. Other variables (plumage condition, presence of breast redness and blisters, pecked tail feathers, and perch use) were indirectly affected......Multi-tier aviary systems, where conveyor belts below the tiers remove the manure at regular intervals, are becoming more common in organic egg production. The area on the tiers can be included in the net area available to the hens (also referred to as usable area) when calculating maximum indoor...

  19. Procedure for Uranium-Molybdenum Density Measurements and Porosity Determination

    Energy Technology Data Exchange (ETDEWEB)

    Prabhakaran, Ramprashad [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Devaraj, Arun [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Joshi, Vineet V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-08-13

    The purpose of this document is to provide guidelines for preparing uranium-molybdenum (U-Mo) specimens, performing density measurements, and computing sample porosity. Typical specimens (solids) will be sheared to small rectangular foils, disks, or pieces of metal. A mass balance, solid density determination kit, and a liquid of known density will be used to determine the density of U-Mo specimens using the Archimedes principle. A standard test weight of known density would be used to verify proper operation of the system. By measuring the density of a U-Mo sample, it is possible to determine its porosity.

  20. An Empirical Measure for Labor Market Density

    NARCIS (Netherlands)

    P.A. Gautier (Pieter); C.N. Teulings (Coen)

    2000-01-01

    textabstractIn this paper we derive a structural measure for labor market density based on the Ellison and Glasear (1997) index for industry concentration''. This labor market density measure serves as a proxy for the number of workers that can reach a certain work area within a reasonal amount of t

  1. Absolute density measurements in the middle atmosphere

    Directory of Open Access Journals (Sweden)

    M. Rapp

    Full Text Available In the last ten years a total of 25 sounding rockets employing ionization gauges have been launched at high latitudes ( ~ 70° N to measure total atmospheric density and its small scale fluctuations in an altitude range between 70 and 110 km. While the determination of small scale fluctuations is unambiguous, the total density analysis has been complicated in the past by aerodynamical disturbances leading to densities inside the sensor which are enhanced compared to atmospheric values. Here, we present the results of both Monte Carlo simulations and wind tunnel measurements to quantify this aerodynamical effect. The comparison of the resulting ‘ram-factor’ profiles with empirically determined density ratios of ionization gauge measurements and falling sphere measurements provides excellent agreement. This demonstrates both the need, but also the possibility, to correct aerodynamical influences on measurements from sounding rockets. We have determined a total of 20 density profiles of the mesosphere-lower-thermosphere (MLT region. Grouping these profiles according to season, a listing of mean density profiles is included in the paper. A comparison with density profiles taken from the reference atmospheres CIRA86 and MSIS90 results in differences of up to 40%. This reflects that current reference atmospheres are a significant potential error source for the determination of mixing ratios of, for example, trace gas constituents in the MLT region.

    Key words. Middle atmosphere (composition and chemistry; pressure, density, and temperature; instruments and techniques

  2. Vision-based measurement system for structural vibration monitoring using non-projection quasi-interferogram fringe density enhanced by spectrum correction method

    Science.gov (United States)

    Zhong, Jianfeng; Zhong, Shuncong; Zhang, Qiukun; Zhuang, Yizhou; Lu, Huancai; Fu, Xinbin

    2017-01-01

    A non-projection fringe vision measurement system suitable for vibration monitoring was proposed by using the concept of a 2D optical coherence vibration tomography (2D-OCVT) technique. An artificial quasi-interferogram fringe pattern (QIFP), similar to the interferogram of the 2D-OCVT system, was pasted onto the surface of a vibrating structure as a sensor. Image sequences of the QIFP were captured by a high-speed CMOS camera that worked as a detector. It was possible to obtain both the in-plane and out-of-plane vibration simultaneously. The in-plane vibration was obtained by tracking the center of the imaged QIFP using an image cross-correlation method, whilst the out-of-plane vibration was obtained from the changes in period density of the imaged QIFP. The influence of the noise sources from the CMOS image sensor, together with the effect of the imaging distance, the period density of the QIFP and also the key parameters of the fringe density enhanced by the spectrum correction method on the accuracy of the displacement measurement, were investigated by numerical simulations and experiments. Compared with the results from a conventional accelerometer-based measurement system, the proposed method was demonstrated to be an effective and accurate technique for measuring structural vibration without introducing any extra mass from the accelerometer. The significant advantages of this method include its simple installation and real-time dynamic response measurement capability, making the measurement system ideal for the low- and high-frequency vibration monitoring of engineering structures.

  3. Laser-based air data system for aircraft control using Raman and elastic backscatter for the measurement of temperature, density, pressure, moisture, and particle backscatter coefficient.

    Science.gov (United States)

    Fraczek, Michael; Behrendt, Andreas; Schmitt, Nikolaus

    2012-01-10

    Flight safety in all weather conditions demands exact and reliable determination of flight-critical air parameters. Air speed, temperature, density, and pressure are essential for aircraft control. Conventional air data systems can be impacted by probe failure caused by mechanical damage from hail, volcanic ash, and icing. While optical air speed measurement methods have been discussed elsewhere, in this paper, a new concept for optically measuring the air temperature, density, pressure, moisture, and particle backscatter is presented, being independent on assumptions on the atmospheric state and eliminating the drawbacks of conventional aircraft probes by providing a different measurement principle. The concept is based on a laser emitting laser pulses into the atmosphere through a window and detecting the signals backscattered from a fixed region just outside the disturbed area of the fuselage flows. With four receiver channels, different spectral portions of the backscattered light are extracted. The measurement principle of air temperature and density is based on extracting two signals out of the rotational Raman (RR) backscatter signal of air molecules. For measuring the water vapor mixing ratio-and thus the density of the moist air-a water vapor Raman channel is included. The fourth channel serves to detect the elastic backscatter signal, which is essential for extending the measurements into clouds. This channel contributes to the detection of aerosols, which is interesting for developing a future volcanic ash warning system for aircraft. Detailed and realistic optimization and performance calculations have been performed based on the parameters of a first prototype of such a measurement system. The impact and correction of systematic error sources, such as solar background at daytime and elastic signal cross talk appearing in optically dense clouds, have been investigated. The results of the simulations show the high potential of the proposed system for

  4. Study of Bone Mineral Density Measuring System with Quantitative CT%定量CT骨矿密度测量系统的研制

    Institute of Scientific and Technical Information of China (English)

    刘景鑫; 张光; 孙晶; 韩邕; 韩学峰

    2001-01-01

    介绍一种定量CT骨矿密度测量系统。系统包括自制的固体骨矿密度CT测量校准模体和测量分析软件系统。检测表明该系统准确可靠,经济实用。%This paper introduces a kind of bone mineral density(BMD) measuring system with quantitative CT(QCT). This system includs a self-made solid calibration phantom for BMD and the measuring software. The results of the tests have showed that this system is reliable,cheap and ease of use for BMD measurement.

  5. Spacetime Average Density (SAD) Cosmological Measures

    CERN Document Server

    Page, Don N

    2014-01-01

    The measure problem of cosmology is how to obtain normalized probabilities of observations from the quantum state of the universe. This is particularly a problem when eternal inflation leads to a universe of unbounded size so that there are apparently infinitely many realizations or occurrences of observations of each of many different kinds or types, making the ratios ambiguous. There is also the danger of domination by Boltzmann Brains. Here two new Spacetime Average Density (SAD) measures are proposed, Maximal Average Density (MAD) and Biased Average Density (BAD), for getting a finite number of observation occurrences by using properties of the Spacetime Average Density (SAD) of observation occurrences to restrict to finite regions of spacetimes that have a preferred beginning or bounce hypersurface. These measures avoid Boltzmann brain domination and appear to give results consistent with other observations that are problematic for other widely used measures, such as the observation of a positive cosmolo...

  6. Development of a vector-tensor system to measure the absolute magnetic flux density and its gradient in magnetically shielded rooms.

    Science.gov (United States)

    Voigt, J; Knappe-Grüneberg, S; Gutkelch, D; Haueisen, J; Neuber, S; Schnabel, A; Burghoff, M

    2015-05-01

    Several experiments in fundamental physics demand an environment of very low, homogeneous, and stable magnetic fields. For the magnetic characterization of such environments, we present a portable SQUID system that measures the absolute magnetic flux density vector and the gradient tensor. This vector-tensor system contains 13 integrated low-critical temperature (LTc) superconducting quantum interference devices (SQUIDs) inside a small cylindrical liquid helium Dewar with a height of 31 cm and 37 cm in diameter. The achievable resolution depends on the flux density of the field under investigation and its temporal drift. Inside a seven-layer mu-metal shield, an accuracy better than ±23 pT for the components of the static magnetic field vector and ±2 pT/cm for each of the nine components of the gradient tensor is reached by using the shifting method.

  7. Measuring liquid density using Archimedes' principle

    Science.gov (United States)

    Hughes, Stephen W.

    2006-09-01

    A simple technique is described for measuring absolute and relative liquid density based on Archimedes' principle. The technique involves placing a container of the liquid under test on an electronic balance and suspending a probe (e.g. a glass marble) attached to a length of line beneath the surface of the liquid. If the volume of the probe is known, the density of liquid is given by the difference between the balance reading before and after immersion of the probe divided by the volume of the probe. A test showed that the density of water at room temperature could be measured to an accuracy and precision of 0.01 ± 0.1%. The probe technique was also used to measure the relative density of milk, Coca-Cola, fruit juice, olive oil and vinegar.

  8. Measurement of Density Inhomogeneity for Glass Pendulum

    Institute of Scientific and Technical Information of China (English)

    LIU Lin-Xia; LIU Qi; SHAO Cheng-Gang; ZHANG Ya-Ting; LUO Jun; Vadim Milyukov

    2008-01-01

    @@ The density inhomogeneity of a glass pendulum is determined by an optical interference method.The relative variations of the densities over a volume with sizes of 5 × 5 × 5mm3 are (0.64±0.97) × 10-5 and (0.99 ± 0.92) ×10-5 for the K9 glass and silica glass pendulum, respectively.These variations of densities contributing to the relative uncertainties of the Newtonian gravitational constant G are 0.20 ppm and 0.21 ppm in our experiment on measurement of G.

  9. Systemic risk measures

    Science.gov (United States)

    Guerra, Solange Maria; Silva, Thiago Christiano; Tabak, Benjamin Miranda; de Souza Penaloza, Rodrigo Andrés; de Castro Miranda, Rodrigo César

    2016-01-01

    In this paper we present systemic risk measures based on contingent claims approach and banking sector multivariate density. We also apply network measures to analyze bank common risk exposure. The proposed measures aim to capture credit risk stress and its potential to become systemic. These indicators capture not only individual bank vulnerability, but also the stress dependency structure between them. Furthermore, these measures can be quite useful for identifying systemically important banks. The empirical results show that these indicators capture with considerable fidelity the moments of increasing systemic risk in the Brazilian banking sector in recent years.

  10. Density measurements using coherence imaging spectroscopy based on Stark broadeninga)

    Science.gov (United States)

    Lischtschenko, O.; Bystrov, K.; De Temmerman, G.; Howard, J.; Jaspers, R. J. E.; König, R.

    2010-10-01

    A coherence imaging camera has been set up at Pilot-PSI. The system is to be used for imaging the plasma density through the Stark effect broadening of the Hγ line. Local density values are then obtained by the Abel inversion of the measured interferometric fringe contrast. This report will present the instrument setup and proof-of-principle demonstration. The inverted spatial electron density profiles obtained near the cascaded arc source of Pilot-PSI in discharges with axial magnetic field of B=0.4 T are compared with an independent measurement of electron density by Thomson scattering and good agreement is found.

  11. Density measurements using coherence imaging spectroscopy based on Stark broadening

    Energy Technology Data Exchange (ETDEWEB)

    Lischtschenko, O.; Bystrov, K.; De Temmerman, G. [Association EURATOM-FOM, FOM-Institute for Plasma Physics Rijnhuizen, partner in the Trilateral Euregio Cluster, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Howard, J. [Research Laboratory, Australian National University, Canberra, Australian Capital Territory 0200 (Australia); Jaspers, R. J. E. [Fusion Group, Eindhoven University of Technology, Postbus 513, 5600 MB Eindhoven (Netherlands); Koenig, R. [EURATOM Association, Max-Planck-Institut fuer Plasmaphysik, TI Greifswald, Wendelsteinstr.1, D-17491 Greifswald (Germany)

    2010-10-15

    A coherence imaging camera has been set up at Pilot-PSI. The system is to be used for imaging the plasma density through the Stark effect broadening of the H{sub {gamma}} line. Local density values are then obtained by the Abel inversion of the measured interferometric fringe contrast. This report will present the instrument setup and proof-of-principle demonstration. The inverted spatial electron density profiles obtained near the cascaded arc source of Pilot-PSI in discharges with axial magnetic field of B=0.4 T are compared with an independent measurement of electron density by Thomson scattering and good agreement is found.

  12. Write-once optical disk system measuring 300 mm using high-density, pit-edge recording.

    Science.gov (United States)

    Maeda, T; Saito, A; Sugiyama, H; Arai, S; Shigematsu, K

    1995-08-01

    To meet the requirement for a second-generation digital optical disk with a larger capacity and a higher speed, the new 300-mm, write-once optical disk system described here uses pit-edge recording and the modified-constant-angular-velocity method [Maeda et al., Trans. IEICE E74, 951 (1991)]. New techniques that can use these methods together and are suitable for interchangeability-data composition and independent detection of the leading and trailing edges-have resulted in the most reliable data-storage system ever produced, we believe. The concept of this system, the characteristics of the new techniques, and the optimization of system performance are described.

  13. Single particle counting diagnostic system for measuring fine particulates at high number densities in research and industrial applications. Final report summarizing instrument development, validation and operating instructions

    Energy Technology Data Exchange (ETDEWEB)

    Holve, D.J.

    1983-10-01

    Optical methods for particle size distribution measurements in practical high temperature environments have achieved feasibility and offer significant advantages over conventional sampling methods. The present report describes a mobile electro-optical system which has been designed for general use in a wide range of research and industrial environments. Specific features of this system include a method of providing in situ alignment and incorporation of an extinction measurement for application to optically thick aerosol flows. The instrument has demonstrated capability for measuring individual particles in the size range 0.25 to 100 microns at number densities up to 10/sup 12//m/sup 3/. In addition to demonstration of the system's wide dynamic range, we show the utility of the in situ alignment method in hot (1100 K) turbulent flows where beam steering can be a problem. As an example of the instrument's application, number and mass frequency distribution measurements of flyash and pulverized coal obtained in an atmospheric combustion exhaust simulator show that the raw pulverized coal contains large numbers of submicron particles similar to the flyash formed after combustion.

  14. Hydrogen density measurements using an open-ended microwave cavity.

    Science.gov (United States)

    Wenger, N. C.; Smetana, J.

    1972-01-01

    The density measurement of liquid hydrogen and two-phase mixtures of liquid and gaseous hydrogen is considered. This paper describes a complete prototype system that uses an open-ended microwave cavity for making dynamic density measurements of flowing hydrogen in a transfer line. The theory of operation along with test results for both the single- and two-phase cases are presented and discussed.

  15. Biases of CO2 Storage in Eddy Flux Measurements pertinent to Vertical Configurations of a Profile System and CO2 Density Averaging

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Bai [ORNL; Hanson, Paul J [ORNL; Riggs, Jeffery S [ORNL; Pallardy, Stephen G. [University of Missouri; Hosman, K. P. [University of Missouri; Meyers, T. P. [NOAA ATDD; Wullschleger, Stan D [ORNL; Gu, Lianhong [ORNL; Heuer, Mark [ATDD, NOAA

    2007-01-01

    CO2 storage in a 30-minute period in a tall forest canopy often makes significant contributions to net ecosystem exchange (NEE) in the early morning and at night. When CO2 storage is properly measured and taken into account, underestimations of NEE on calm nights can be greatly reduced. Using CO2 data from a 12-level profile, we demonstrate that the lower canopy layer (below the thermal inversion) is a disproportional contributor to the total CO2 storage. This is because time derivative of CO2 density ( c/ t) generally shows increasing magnitude of mean and standard deviation with decreasing heights at night and from sunrise to 1000 hr in both growing and dormant seasons. Effects of resolution and configuration in a profiling system on the accuracy of CO2 storage estimation are evaluated by comparing subset profiles to the 12-level benchmark profile. It is demonstrated that the effectiveness of a profiling system in estimating CO2 storage is not only determined by its number of sampling levels but, more importantly, by its vertical configuration. To optimize a profile, one needs to balance the influence of two factors, c/ t and layer thickness, among all vertical sections within a forest. As a key contributor to the total CO2 storage, the lower canopy (with relatively large means and standard deviations of c/ t) requires a higher resolution in a profile system than the layers above. However, if the upper canopy is over-sparsely sampled relative to the lower canopy, the performance of a profile system might be degraded since, in such a situation, the influence of layer thickness dominates over that of c/ t. We also find that, because of different level of complexity in canopy structure, more sampling levels are necessary at our site in order to achieve the same level of accuracy as at a boreal aspen site. These results suggest that, in order to achieve an adequate accuracy in CO2 storage measurements, the number of sampling levels in a profile and its design should

  16. Ultrasonic Technique for Density Measurement of Liquids in Extreme Conditions

    Directory of Open Access Journals (Sweden)

    Rymantas Kazys

    2015-08-01

    Full Text Available An ultrasonic technique, invariant to temperature changes, for a density measurement of different liquids under in situ extreme conditions is presented. The influence of geometry and material parameters of the measurement system (transducer, waveguide, matching layer on measurement accuracy and reliability is analyzed theoretically along with experimental results. The proposed method is based on measurement of the amplitude of the ultrasonic wave, reflected from the interface of the solid/liquid medium under investigation. In order to enhance sensitivity, the use of a quarter wavelength acoustic matching layer is proposed. Therefore, the sensitivity of the measurement system increases significantly. Density measurements quite often must be performed in extreme conditions at high temperature (up to 220 °C and high pressure. In this case, metal waveguides between piezoelectric transducer and the measured liquid are used in order to protect the conventional transducer from the influence of high temperature and to avoid depolarization. The presented ultrasonic density measurement technique is suitable for density measurement in different materials, including liquids and polymer melts in extreme conditions. A new calibration algorithm was proposed. The metrological evaluation of the measurement method was performed. The expanded measurement uncertainty Uρ = 7.4 × 10−3 g/cm3 (1%.

  17. Measuring Air Density in the Introductory Lab

    Science.gov (United States)

    Calzà, G.; Gratton, L. M.; López-Arias, T.; Oss, S.

    2010-03-01

    The measurement of the mass, or the density, of air can easily be done with very simple materials and offers many interesting phenomena for discussion—buoyancy and its effects being the most obvious but not the only one. Many interesting considerations can be done regarding the behavior of gases, the effect of the external conditions in the measurement, and the reason for the choice of the procedure, among others. One of the most widespread approaches makes use of rubber balloons. Such an approach can be misleading if attention is not paid to the effect of the buoyant force on the balloon, exerted by the surrounding air. Air is weightless in an environment full of it. While this fact can usually be neglected in daily, nontechnical weight measurements, it is not the case when we are interested in the weight of air itself. A sketch such as the one depicted in Fig. 1 is often presented in elementary science textbooks, as a demonstration that air has weight. A search of the Internet will reveal that this misleading approach is often presented as the simplest one for this kind of measurement at an elementary level and represents one among other common misconceptions that can be found in K-6 science textbooks as discussed, for instance, in Ref. 2. For a more detailed description of the flaws inherent to the measurement of air's weight with a rubber balloon, see Ref. 3. In this paper we will describe two procedures to measure the density of air: weighing a PET bottle and a vacuum rigid container. There are other interesting ways to estimate the weight of air; see, for instance, the experiment of Zhu and Se-yuen using carbon dioxide and Archimedes' principle.4 We emphasize the experimental implications and the physical reasons for the accuracy and conceptual correctness of each method. It is important not to undervalue the importance of both simplicity and reliability for any experimental measurement made in a didactic context.

  18. Mammographic density measurement: a comparison of automated volumetric density measurement to BIRADS

    Science.gov (United States)

    McEntee, Mark F.; Damases, Christine N.

    2014-03-01

    The aim of this study is to compare mammographic breast density assessment with automated volumetric software with Breast Imaging Reporting and Data System (BIRADS) categorization by radiologists on two imaging systems. A data set of 120 mammograms was classified by twenty American Board of Radiology (ABR) Examiners. The mammograms were of 20 women (mean age, 60 years; range, 42-89 years). These women were image twice once with GE system and the following year with Hologic system. These images also had their volumetric density classified by using Volpara Density Grade (VDG). The radiologists were asked to estimate the mammographic density according to BIRADS categories (1- 4). There was a moderate agreement between VDG classification and radiologist BIRADS density shown with Cohen's Kappa (K=0.45; pBIRADS having a mean of 2.13 and the mean VDG higher at 2.50 (t = -11.99; pBIRADS showed a positive strong correlation (r=0.84; pBIRADS and VDG AvBD% also showed a strong positive correlation (r=0.86; pBIRADS categories for each of the VDG AvBD% classifications. Using Volpara, the Hologic system showed a higher meanAvBD% (10.02 vs. 9.97). However using BIRADS the Hologic systems showed a lower mean (2.05 vs. 2.21). Automated systems demonstrated higher internal validity. The results demonstrated a moderate agreement and a strong correlation between VDG classification and radiologist BIRADS density assessment.

  19. Electrochemical thermodynamic measurement system

    Science.gov (United States)

    Reynier, Yvan; Yazami, Rachid; Fultz, Brent T.

    2009-09-29

    The present invention provides systems and methods for accurately characterizing thermodynamic and materials properties of electrodes and electrochemical energy storage and conversion systems. Systems and methods of the present invention are configured for simultaneously collecting a suite of measurements characterizing a plurality of interconnected electrochemical and thermodynamic parameters relating to the electrode reaction state of advancement, voltage and temperature. Enhanced sensitivity provided by the present methods and systems combined with measurement conditions that reflect thermodynamically stabilized electrode conditions allow very accurate measurement of thermodynamic parameters, including state functions such as the Gibbs free energy, enthalpy and entropy of electrode/electrochemical cell reactions, that enable prediction of important performance attributes of electrode materials and electrochemical systems, such as the energy, power density, current rate and the cycle life of an electrochemical cell.

  20. Critical current density: Measurements vs. reality

    Science.gov (United States)

    Pan, A. V.; Golovchanskiy, I. A.; Fedoseev, S. A.

    2013-07-01

    Different experimental techniques are employed to evaluate the critical current density (Jc), namely transport current measurements and two different magnetisation measurements forming quasi-equilibrium and dynamic critical states. Our technique-dependent results for superconducting YBa2Cu3O7 (YBCO) film and MgB2 bulk samples show an extremely high sensitivity of Jc and associated interpretations, such as irreversibility fields and Kramer plots, which lose meaning without a universal approach. We propose such approach for YBCO films based on their unique pinning features. This approach allows us to accurately recalculate the magnetic-field-dependent Jc obtained by any technique into the Jc behaviour, which would have been measured by any other method without performing the corresponding experiments. We also discovered low-frequency-dependent phenomena, governing flux dynamics, but contradicting the considered ones in the literature. The understanding of these phenomena, relevant to applications with moving superconductors, can clarify their dramatic impact on the electric-field criterion through flux diffusivity and corresponding measurements.

  1. 3 dimensional ionospheric electron density reconstruction based on GPS measurements

    Science.gov (United States)

    Stolle, C.; Schlüter, S.; Jacobi, C.; Jakowski, N.

    When radio waves as sended by the naviagtion system GPS are passing through the ionosphere they are subject to delays in phase, travel time and polarisation which is an effect of the free electrons. The measured integrated value of Total Electron Content can be utilised for three-dimensional reconstruction of electron density patterns in the ionosphere. Here a tomographic approach is represented. Scince the distribution of data is very sparse and patchy we decided for an algebraic iterative algorithm. The ground based GPS data collected by IGS receivers can be combined by space based GPS of radio limb sounding, incoherent scatter radar and ionosondes data. Hereby, radio occultation data improve beside the amount of available data especially the vertical resolution of electron density distribution. Ionosonde peack electron densities are taken as stop criteria determination for iteration. Reconstructed ionospheric scenarios and validations of the system by independent measurements are presented.

  2. Measurement of electron temperatures of Argon Plasmas in a High-Density Inductively-Coupled Remote Plasma System by Langmuir Probe and Optical-Emission Spectroscopy

    NARCIS (Netherlands)

    Boogaard, A.; Kovalgin, Alexeij Y.; Aarnink, Antonius A.I.; Wolters, Robertus A.M.; Holleman, J.; Brunets, I.; Schmitz, Jurriaan

    2006-01-01

    We measured electron density and electron energy distribution function (EEDF) in our reactor by a Langmuir probe. The EEDF of Ar plasma in the reactor could largely be described by the Maxwell-Boltzmann distribution function, but it also contained a fraction (~10-3) of electrons which were much

  3. Grain bulk density measurement based on wireless network

    Directory of Open Access Journals (Sweden)

    Wu Fangming

    2017-01-01

    Full Text Available To know the accurate quantity of stored grain, grain density sensors must be used to measure the grain’s bulk density. However, multi-sensors should be inserted into the storage facility, to quickly collect data during the inventory checking of stored grain. In this study, the ZigBee and Wi-Fi coexistence network’s ability to transmit data collected by density sensors was investigated. A system consisting of six sensor nodes, six router nodes, one gateway and one Android Pad was assembled to measure the grain’s bulk density and calculate its quantity. The CC2530 chip with ZigBee technology was considered as the core of the information processing, and wireless nodes detection in sensor, and router nodes. ZigBee worked in difference signal channel with Wi-Fi to avoid interferences and connected with Wi-Fi module by UART serial communications interfaces in gateway. The Android Pad received the measured data through the gateway and processed this data to calculate quantity. The system enabled multi-point and real-time parameter detection inside the grain storage. Results show that the system has characteristics of good expansibility, networking flexibility and convenience.

  4. Cumulative sum quality control for calibrated breast density measurements

    Energy Technology Data Exchange (ETDEWEB)

    Heine, John J.; Cao Ke; Beam, Craig [Cancer Prevention and Control Division, Moffitt Cancer Center, 12902 Magnolia Drive, Tampa, Florida 33612 (United States); Division of Epidemiology and Biostatistics, School of Public Health, University of Illinois at Chicago, 1603 W. Taylor St., Chicago, Illinois 60612 (United States)

    2009-12-15

    Purpose: Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach calibrates for interpatient acquisition technique differences. The calibration produces a normalized breast density pixel value scale. The method relies on first generating a baseline (BL) calibration dataset, which required extensive phantom imaging. Standardizing prospective mammograms with calibration data generated in the past could introduce unanticipated error in the standardized output if the calibration dataset is no longer valid. Methods: Sample points from the BL calibration dataset were imaged approximately biweekly over an extended timeframe. These serial samples were used to evaluate the BL dataset reproducibility and quantify the serial calibration accuracy. The cumulative sum (Cusum) quality control method was used to evaluate the serial sampling. Results: There is considerable drift in the serial sample points from the BL calibration dataset that is x-ray beam dependent. Systematic deviation from the BL dataset caused significant calibration errors. This system drift was not captured with routine system quality control measures. Cusum analysis indicated that the drift is a sign of system wear and eventual x-ray tube failure. Conclusions: The BL calibration dataset must be monitored and periodically updated, when necessary, to account for sustained system variations to maintain the calibration accuracy.

  5. Reineke’s stand density index: a quantitative and non-unitless measure of stand density

    Science.gov (United States)

    Curtis L. VanderSchaaf

    2013-01-01

    When used as a measure of relative density, Reineke’s stand density index (SDI) can be made unitless by relating the current SDI to a standard density but when used as a quantitative measure of stand density SDI is not unitless. Reineke’s SDI relates the current stand density to an equivalent number of trees per unit area in a stand with a quadratic mean diameter (Dq)...

  6. The Physical Density of the City—Deconstruction of the Delusive Density Measure with Evidence from Two European Megacities

    Directory of Open Access Journals (Sweden)

    Hannes Taubenböck

    2016-11-01

    Full Text Available Density is among the most important descriptive as well as normative measures in urban research. While its basic concept is generally understandable, approaches towards the density measure are manifold, diverse and of multidimensional complexity. This evolves from differing thematic, spatial and calculative specifications. Consequently, applied density measures are often used in a subjective, non-transparent, unspecific and thus non-comparable manner. In this paper, we aim at a systematic deconstruction of the measure density. Varying thematic, spatial and calculative dimensions show significant influence on the measure. With both quantitative and qualitative techniques of evaluation, we assess the particular influences on the measure density. To do so, we reduce our experiment setting to a mere physical perspective; that is, the quantitative measures building density, degree of soil sealing, floor space density and, more specifically, the density of generic structural classes such as open spaces and highest built-up density areas. Using up-to-date geodata derived from remote sensing and volunteered geographic information, we build upon high-quality spatial information products such as 3-D city models. Exemplified for the comparison of two European megacities, namely Paris and London, we reveal and systemize necessary variables to be clearly defined for meaningful conclusions using the density measure.

  7. 46 CFR 164.009-17 - Density measurement.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Density measurement. 164.009-17 Section 164.009-17... measurement. (a) The measurements described in this section are made to determine the density of a sample. (b... the specimen. The average of at least four measurements of each dimension is determined. (c) If...

  8. Local density approximations from finite systems

    CERN Document Server

    Entwistle, Mike; Wetherell, Jack; Longstaff, Bradley; Ramsden, James; Godby, Rex

    2016-01-01

    The local density approximation (LDA) constructed through quantum Monte Carlo calculations of the homogeneous electron gas (HEG) is the most common approximation to the exchange-correlation functional in density functional theory. We introduce an alternative set of LDAs constructed from slab-like systems of one, two and three electrons that resemble the HEG within a finite region, and illustrate the concept in one dimension. Comparing with the exact densities and Kohn-Sham potentials for various test systems, we find that the LDAs give a good account of the self-interaction correction, but are less reliable when correlation is stronger or currents flow.

  9. Intercomparison of snow density measurements: bias, precision and spatial resolution

    Directory of Open Access Journals (Sweden)

    M. Proksch

    2015-07-01

    Full Text Available Density is a fundamental property of porous media such as snow. A wide range of snow properties and physical processes are linked to density, but few studies have addressed the uncertainty in snow density measurements. No study has yet considered the recent advances in snow measurement methods such as micro-computed tomography (CT. During the MicroSnow Davos 2014 workshop different approaches to measure snow density were applied in a controlled laboratory environment and in the field. Overall, the agreement between CT and gravimetric methods (density cutters was 5 to 9 %, with a bias of −5 to 2 %, expressed as percentage of the mean CT density. In the field, the density cutters tend to overestimate (1 to 6 % densities below and underestimate (1 to 6 % densities above 296 to 350 kg m−3, respectively, depending on the cutter type. Using the mean per layer of all measurement methods applied in the field (CT, box, wedge and cylinder cutter and ignoring ice layers, the variation of layer density between the methods was 2 to 5 % with a bias of −1 to 1 %. In general, our result suggests that snow densities measured by different methods agree within 9 %. However, the density profiles resolved by the measurement methods differed considerably. In particular, the millimeter scale density variations revealed by the high resolution CT contrasted the thick layers with sharp boundaries introduced by the observer. In this respect, the unresolved variation, i.e. the density variation within a layer, which is lost by sampling with lower resolution or layer aggregation, is critical when snow density measurements are used as boundary or initial conditions in numerical simulations.

  10. Neutron Flux Density Measured by Analysis of Annealing Heat

    Institute of Scientific and Technical Information of China (English)

    WANG; Fan; SHI; Yong-qian; ZHU; Qing-fu; LU; Jin; LI; Lai-dong

    2015-01-01

    Neutron flux density measurement by thermal analysis is a new method different from the previous.This method is first put the sample to the neutron field.Second,measure the annealingheat of the sample.Find out the suitable mixture of crystal boron and apatite to measure the neutron flux density.Then put the sample to the neutron field in

  11. 21 CFR 866.5600 - Low-density lipoprotein immunological test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Low-density lipoprotein immunological test system....5600 Low-density lipoprotein immunological test system. (a) Identification. A low-density lipoprotein... the low-density lipoprotein in serum and other body fluids. Measurement of low-density lipoprotein in...

  12. Quantum probability measures and tomographic probability densities

    NARCIS (Netherlands)

    Amosov, GG; Man'ko, [No Value

    2004-01-01

    Using a simple relation of the Dirac delta-function to generalized the theta-function, the relationship between the tomographic probability approach and the quantum probability measure approach with the description of quantum states is discussed. The quantum state tomogram expressed in terms of the

  13. Smart density: a more accurate method of measuring rural residential density for health-related research

    Directory of Open Access Journals (Sweden)

    Gibson Lucinda

    2010-02-01

    Full Text Available Abstract Background Studies involving the built environment have typically relied on US Census data to measure residential density. However, census geographic units are often unsuited to health-related research, especially in rural areas where development is clustered and discontinuous. Objective We evaluated the accuracy of both standard census methods and alternative GIS-based methods to measure rural density. Methods We compared residential density (units/acre in 335 Vermont school neighborhoods using conventional census geographic units (tract, block group and block with two GIS buffer measures: a 1-kilometer (km circle around the school and a 1-km circle intersected with a 100-meter (m road-network buffer. The accuracy of each method was validated against the actual residential density for each neighborhood based on the Vermont e911 database, which provides an exact geo-location for all residential structures in the state. Results Standard census measures underestimate residential density in rural areas. In addition, the degree of error is inconsistent so even the relative rank of neighborhood densities varies across census measures. Census measures explain only 61% to 66% of the variation in actual residential density. In contrast, GIS buffer measures explain approximately 90% of the variation. Combining a 1-km circle with a road-network buffer provides the closest approximation of actual residential density. Conclusion Residential density based on census units can mask clusters of development in rural areas and distort associations between residential density and health-related behaviors and outcomes. GIS-defined buffers, including a 1-km circle and a road-network buffer, can be used in conjunction with census data to obtain a more accurate measure of residential density.

  14. Thermospheric mass density measurement from precise orbit ephemeris

    Directory of Open Access Journals (Sweden)

    Junyu Chen

    2016-05-01

    Full Text Available Atmospheric drag, which can be inferred from orbit information of low-Earth orbiting (LEO satellites, provides a direct means of measuring mass density. The temporal resolution of derived mass density could be in the range from minutes to days, depending on the precision of the satellite orbit data. This paper presents two methods potentially being able to estimate thermosphere mass density from precise obit ephemeris with high temporal resolution. One method is based on the drag perturbation equation of the semi-major axis and the temporal resolution of retrieved density could be 150 s for CHAMP satellite. Another method generates corrections to densities computed from a baseline density model through a Kalman filter orbit drag coefficient determination (KFOD process and the temporal resolution of derived density could be as high as 30 s for CHAMP satellite. The densities estimated from these two methods are compared with densities obtained from accelerometer data of CHAMP satellite. When the accelerometer data based densities are used as reference values, the mean relative accuracy of the densities derived from precision orbit data using the two methods is within approximately 10%. An application of the derived densities shows that the derived densities can reduce orbit predication errors.

  15. Thermospheric mass density measurement from precise orbit ephemeris

    Institute of Scientific and Technical Information of China (English)

    Junyu Chen; Jizhang Sang

    2016-01-01

    Atmospheric drag,which can be inferred from orbit information of low-Earth orbiting (LEO)satellites,provides a direct means of measuring mass density.The temporal resolution of derived mass density could be in the range from minutes to days,depending on the precision of the satellite orbit data.This paper presents two methods potentially being able to estimate thermosphere mass density from precise obit ephemeris with high temporal resolution.One method is based on the drag perturbation equation of the semi-major axis and the temporal resolution of retrieved density could be 150 s for CHAMP satellite.Another method generates corrections to densities computed from a baseline density model through a Kalman filter orbit drag coefficient determination (KFOD) process and the temporal resolution of derived density could be as high as 30 s for CHAMP satellite.The densities estimated from these two methods are compared with densities obtained from accelerometer data of CHAMP satellite.When the accelerometer data based densities are used as reference values,the mean relative accuracy of the densities derived from precision orbit data using the two methods is within approximately 10%.An application of the derived densities shows that the derived densities can reduce orbit predication errors.

  16. Non-invasive fluid density and viscosity measurement

    Science.gov (United States)

    Sinha, Dipen N.

    2012-05-01

    The noninvasively measurement of the density and viscosity of static or flowing fluids in a section of pipe such that the pipe performs as the sensing apparatus, is described. Measurement of a suitable structural vibration resonance frequency of the pipe and the width of this resonance permits the density and viscosity to be determined, respectively. The viscosity may also be measured by monitoring the decay in time of a vibration resonance in the pipe.

  17. Electron density and gas density measurements in a millimeter-wave discharge

    Energy Technology Data Exchange (ETDEWEB)

    Schaub, S. C., E-mail: sschaub@mit.edu; Hummelt, J. S.; Guss, W. C.; Shapiro, M. A.; Temkin, R. J. [Plasma Science and Fusion Center, Massachusetts Institute of Technology 167 Albany St., Bldg. NW16, Cambridge, Massachusetts 02139 (United States)

    2016-08-15

    Electron density and neutral gas density have been measured in a non-equilibrium air breakdown plasma using optical emission spectroscopy and two-dimensional laser interferometry, respectively. A plasma was created with a focused high frequency microwave beam in air. Experiments were run with 110 GHz and 124.5 GHz microwaves at powers up to 1.2 MW. Microwave pulses were 3 μs long at 110 GHz and 2.2 μs long at 124.5 GHz. Electron density was measured over a pressure range of 25 to 700 Torr as the input microwave power was varied. Electron density was found to be close to the critical density, where the collisional plasma frequency is equal to the microwave frequency, over the pressure range studied and to vary weakly with input power. Neutral gas density was measured over a pressure range from 150 to 750 Torr at power levels high above the threshold for initiating breakdown. The two-dimensional structure of the neutral gas density was resolved. Intense, localized heating was found to occur hundreds of nanoseconds after visible plasma formed. This heating led to neutral gas density reductions of greater than 80% where peak plasma densities occurred. Spatial structure and temporal dynamics of gas heating at atmospheric pressure were found to agree well with published numerical simulations.

  18. Paramagnetic ionic liquids for measurements of density using magnetic levitation.

    Science.gov (United States)

    Bwambok, David K; Thuo, Martin M; Atkinson, Manza B J; Mirica, Katherine A; Shapiro, Nathan D; Whitesides, George M

    2013-09-03

    Paramagnetic ionic liquids (PILs) provide new capabilities to measurements of density using magnetic levitation (MagLev). In a typical measurement, a diamagnetic object of unknown density is placed in a container containing a PIL. The container is placed between two magnets (typically NdFeB, oriented with like poles facing). The density of the diamagnetic object can be determined by measuring its position in the magnetic field along the vertical axis (levitation height, h), either as an absolute value or relative to internal standards of known density. For density measurements by MagLev, PILs have three advantages over solutions of paramagnetic salts in aqueous or organic solutions: (i) negligible vapor pressures; (ii) low melting points; (iii) high thermal stabilities. In addition, the densities, magnetic susceptibilities, glass transition temperatures, thermal decomposition temperatures, viscosities, and hydrophobicities of PILs can be tuned over broad ranges by choosing the cation-anion pair. The low melting points and high thermal stabilities of PILs provide large liquidus windows for density measurements. This paper demonstrates applications and advantages of PILs in density-based analyses using MagLev.

  19. Quantitatively measuring the orbital angular momentum density of light : Presentation

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2013-08-01

    Full Text Available Although many techniques are efficient at measuring optical orbital angular momentum (OAM), they do not allow one to obtain a quantitative measurement for the OAM density across an optical field and instead only measure its global OAM. Numerous...

  20. The new method for the residual gas density measurements

    CERN Document Server

    Anashin, V V; Krasnov, A A; Malyshev, O B; Nas'mov, V P; Pyata, E I; Shaftan, T V

    2001-01-01

    A new method of measurement for residual gas density in the vacuum chambers in presence of synchrotron radiation (SR) is described. The method is based on using a photomultiplier tube for the detection of the SR-stimulated residual gas luminescence, which is proportional to the residual gas density and SR intensity. The design of the experimental setup and results of the measurements of densities of residual gases (H sub 2 , CO sub 2 , CO, N sub 2 , Ar and O sub 2) are submitted.

  1. Measurement System & Calibration report

    DEFF Research Database (Denmark)

    Kock, Carsten Weber; Vesth, Allan

    This Measurement System & Calibration report is describing DTU’s measurement system installed at a specific wind turbine. A major part of the sensors has been installed by others (see [1]) the rest of the sensors have been installed by DTU. The results of the measurements, described in this report...

  2. Measured Predictively by a Density-Salinity Refractometer

    Directory of Open Access Journals (Sweden)

    Simonetta Lorenzon

    2011-01-01

    Proteins are major contributors to hemolymph density, and the present study correlates the easy and low cost measure of hemolymph density by a density-salinity refractometer with the total protein concentration, measured with a colorimetric method. Moreover, the study evaluates the accuracy of the relationship and provides a conversion factor from hemolymph density to protein in seven species of crustaceans, representative of taxa far apart in the phylogenetic tree and characterized by different life habits. Measuring serum-protein concentration by using a refractometer can provide a non-destructive field method to assess crustacean populations/species protein-related modifications of physiological state without need of costly laboratory facilities and procedures.

  3. Wireless Sensor Node for Surface Seawater Density Measurements

    Directory of Open Access Journals (Sweden)

    Roberto Saletti

    2012-03-01

    Full Text Available An electronic meter to measure surface seawater density is presented. It is based on the measurement of the difference in displacements of a surface level probe and a weighted float, which according to Archimedes’ law depends on the density of the water. The displacements are simultaneously measured using a high-accuracy magnetostrictive sensor, to which a custom electronic board provides a wireless connection and power supply so that it can become part of a wireless sensor network. The electronics are designed so that different kinds of wireless networks can be used, by simply changing the wireless module and the relevant firmware of the microcontroller. Lastly, laboratory and at-sea tests are presented and discussed in order to highlight the functionality and the performance of a prototype of the wireless density meter node in a Bluetooth radio network. The experimental results show a good agreement of the values of the calculated density compared to reference hydrometer readings.

  4. Regional time-density measurement of myocardial perfusion

    Science.gov (United States)

    Eusemann, Christian D.; Breen, Jerome F.; Robb, Richard A.

    2003-05-01

    The measurement of time-density relationships of the myocardium in studies of Magnetic Resonance perfusion data sets is a clinical technique used in assessing myocardial perfusion. Traditionally, to measure the time-density relationship a physician draws a region on the same 2-D image of the myocardium in sequential cardiac cycles. Throughout multiple cardiac cycles the density changes in this region are measured. A major limitation of this technique is change in anatomy relative to the selected region on the myocardium during consecutive cardiac cycles. This causes measurement errors, which are amplified if the traced region does not encompass the entire myocardial thickness, or includes a boundary exterior to the epicardial or endocardial surface. The technique described in this paper uses approximately the same myocardial region throughout the entire perfusion study, which insures inclusion of the entire endocardial to epicardial region and exclusion of exterior regions. Moreover, this region can be subdivided into smaller regions of interest. This can be accomplished by careful segmentation and reformatting of the data into polar coordinates. This allows sectioning both axially and transaxially through the myocardium permitting regional assessment of perfusion specific values such as maximum and/or the time to reach maximum density. These values can then be illustrated using density-mapped colors or time-density curves. This measurement and display technique may provide enhanced detection and evaluation of regional deficits in myocardial contractility and perfusion.

  5. Health System Measurement Project

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Health System Measurement Project tracks government data on critical U.S. health system indicators. The website presents national trend data as well as detailed...

  6. Measurement and analyses of molten Ni-Co alloy density

    Institute of Scientific and Technical Information of China (English)

    XIAO Feng; K. MUKAI; FANG Liang; FU Ya; YANG Ren-hui

    2006-01-01

    With the advent of powerful mathematical modeling techniques for material phenomena, there is renewed interest in reliable data for the density of the Ni-based superalloys. Up to now, there has been few report on the density of molten Ni-Co alloy.In order to obtain more accurate density data for molten Ni-Co alloy, the density of molten Ni-Co alloy was measured with a modified sessile drop method, and the accommodation of different atoms in molten Ni-Co alloy was analyzed. The density of alloy is found to decrease with increasing temperature and Co concentration in the alloy. The molar volume of molten Ni-Co alloy increases with increasing Co concentration. The molar volume of Ni-Co alloy determined shows a positive deviation from the linear molar volume, and the deviation of molar volume from ideal mixing increases with increasing Co concentration over the experimental concentration range.

  7. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Acharya, Viral V.; Heje Pedersen, Lasse; Philippon, Thomas

    We present a simple model of systemic risk and we show that each financial institution's contribution to systemic risk can be measured as its systemic expected shortfall (SES), i.e., its propensity to be undercapitalized when the system as a whole is undercapitalized. SES increases...

  8. Electrostatic density measurements in green-state PM parts

    Science.gov (United States)

    Leuenberger, Georg H. W.

    The goal of this research is to show the feasibility of detecting density variations in greenstate powder metallurgy (P/M) compacts from surface voltage measurements. By monitoring a steady electric current flow through the sample and recording the voltages over the surface, valuable information is gathered leading to the prediction of the structural health of the compacts. Unlike prior research that concentrated on the detection of surface-breaking and subsurface defects, the results presented in this thesis target the density prediction throughout the volume of the sample. The detection of density variations is achieved by establishing a correlation between the conductivity and their respective density. The data obtained from the surface measurements is used as part of an inversion algorithm, calculating the conductivity distribution, and subsequently the density within the compact. In a first step, the relationship between conductivity and density of green-state P/M compacts was investigated. Tests were conducted for a number of parts of various powder mixtures. In all cases a clear correlation between conductivity and density could be established, indicating that measurements of electric conductivity could indeed be exploited in an effort to render valid information about the density of the sample under test. We found a linear correlation for nonlubricated parts and a non-linear behavior for lubricated samples. Specifically, it was found that the conductivity increases with increasing density only up to a maximum value obtained at approximately 6.9g/cm 3. Interestingly, any additional density increase leads to a reduction of the conductivity. This behavior was confirmed to be inherent in all powder mixtures with lubricants. The thesis research is able to provide a physical model and a mathematical formulation describing this counter-intuitive phenomenon. A finite element solver in conjunction with an inversion algorithm was then implemented to study arbitrarily

  9. Finding the Density of Objects without Measuring Mass and Volume

    Science.gov (United States)

    Mumba, Frackson; Tsige, Mesfin

    2007-01-01

    A simple method based on the moment of forces and Archimedes' principle is described for finding density without measuring the mass and volume of an object. The method involves balancing two unknown objects of masses M[subscript 1] and M[subscript 2] on each side of a pivot on a metre rule and measuring their corresponding moment arms. The object…

  10. Void alignment and density profile applied to measuring cosmological parameters

    CERN Document Server

    Dai, De-Chang

    2015-01-01

    We study the orientation and density profiles of the cosmological voids with SDSS10 data. Using voids to test Alcock-Paczynski effect has been proposed and tested in both simulations and actual SDSS data. Previous observations imply that there exist an empirical stretching factor which plays an important role in the voids' orientation. Simulations indicate that this empirical stretching factor is caused by the void galaxies' peculiar velocities. Recently Hamaus et al. found that voids' density profiles are universal and their average velocities satisfy linear theory very well. In this article we first confirm that the stretching effect exists using independent analysis. We then apply the universal density profile to measure the cosmological parameters. We find that the void density profile can be a tool to measure the cosmological parameters.

  11. Measurements of electron density profiles using an angular filter refractometer

    Energy Technology Data Exchange (ETDEWEB)

    Haberberger, D., E-mail: dhab@lle.rochester.edu; Ivancic, S.; Hu, S. X.; Boni, R.; Barczys, M.; Craxton, R. S.; Froula, D. H. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14636 (United States)

    2014-05-15

    A novel diagnostic technique, angular filter refractometry (AFR), has been developed to characterize high-density, long-scale-length plasmas relevant to high-energy-density physics experiments. AFR measures plasma densities up to 10{sup 21} cm{sup −3} with a 263-nm probe laser and is used to study the plasma expansion from CH foil and spherical targets that are irradiated with ∼9 kJ of ultraviolet (351-nm) laser energy in a 2-ns pulse. The data elucidate the temporal evolution of the plasma profile for the CH planar targets and the dependence of the plasma profile on target radius for CH spheres.

  12. Density and Temperature Measurements in a Solar Active Region

    Science.gov (United States)

    Warren, Harry P.; Winebarger, Amy R.

    2003-10-01

    We present electron density and temperature measurements from an active region observed above the limb with the Solar Ultraviolet Measurements of Emitted Radiation spectrometer on the Solar and Heliospheric Observatory. Density-sensitive line ratios from Si VIII and S X indicate densities greater than 108 cm-3 as high as 200" (or 145 Mm) above the limb. At these heights, static, uniformly heated loop models predict densities close to 107 cm-3. Differential emission measure analysis shows that the observed plasma is nearly isothermal with a mean temperature of about 1.5 MK and a dispersion of about 0.2 MK. Both the differential emission measure and the Si XI/Si VIII line ratios indicate only small variations in the temperature at the heights observed. These measurements confirm recent observations from the Transition Region and Coronal Explorer of ``overdense'' plasma at temperatures near 1 MK in solar active regions. Time-dependent hydrodynamic simulations suggest that impulsive heating models can account for the large densities, but they have a difficult time reproducing the narrow range of observed temperatures. The observations of overdense, nearly isothermal plasma in the solar corona provide a significant challenge to theories of coronal heating.

  13. High-Sensitivity Measurement of Density by Magnetic Levitation.

    Science.gov (United States)

    Nemiroski, Alex; Kumar, A A; Soh, Siowling; Harburg, Daniel V; Yu, Hai-Dong; Whitesides, George M

    2016-03-01

    This paper presents methods that use Magnetic Levitation (MagLev) to measure very small differences in density of solid diamagnetic objects suspended in a paramagnetic medium. Previous work in this field has shown that, while it is a convenient method, standard MagLev (i.e., where the direction of magnetization and gravitational force are parallel) cannot resolve differences in density mm) because (i) objects close in density prevent each other from reaching an equilibrium height due to hard contact and excluded volume, and (ii) using weaker magnets or reducing the magnetic susceptibility of the medium destabilizes the magnetic trap. The present work investigates the use of weak magnetic gradients parallel to the faces of the magnets as a means of increasing the sensitivity of MagLev without destabilization. Configuring the MagLev device in a rotated state (i.e., where the direction of magnetization and gravitational force are perpendicular) relative to the standard configuration enables simple measurements along the axes with the highest sensitivity to changes in density. Manipulating the distance of separation between the magnets or the lengths of the magnets (along the axis of measurement) enables the sensitivity to be tuned. These modifications enable an improvement in the resolution up to 100-fold over the standard configuration, and measurements with resolution down to 10(-6) g/cm(3). Three examples of characterizing the small differences in density among samples of materials having ostensibly indistinguishable densities-Nylon spheres, PMMA spheres, and drug spheres-demonstrate the applicability of rotated Maglev to measuring the density of small (0.1-1 mm) objects with high sensitivity. This capability will be useful in materials science, separations, and quality control of manufactured objects.

  14. Precision volume measurement system.

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Erin E.; Shugard, Andrew D.

    2004-11-01

    A new precision volume measurement system based on a Kansas City Plant (KCP) design was built to support the volume measurement needs of the Gas Transfer Systems (GTS) department at Sandia National Labs (SNL) in California. An engineering study was undertaken to verify or refute KCP's claims of 0.5% accuracy. The study assesses the accuracy and precision of the system. The system uses the ideal gas law and precise pressure measurements (of low-pressure helium) in a temperature and computer controlled environment to ratio a known volume to an unknown volume.

  15. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Acharya, Viral V.; Heje Pedersen, Lasse; Philippon, Thomas

    2017-01-01

    We present an economic model of systemic risk in which undercapitalization of the financial sector as a whole is assumed to harm the real economy, leading to a systemic risk externality. Each financial institution’s contribution to systemic risk can be measured as its systemic expected shortfall...... of components of SES to predict emerging systemic risk during the financial crisis of 2007–2009....

  16. Simulation of density measurements in plasma wakefields using photo acceleration

    CERN Document Server

    Kasim, Muhammad Firmansyah; Ceurvorst, Luke; Sadler, James; Burrows, Philip N; Trines, Raoul; Holloway, James; Wing, Matthew; Bingham, Robert; Norreys, Peter

    2015-01-01

    One obstacle in plasma accelerator development is the limitation of techniques to diagnose and measure plasma wakefield parameters. In this paper, we present a novel concept for the density measurement of a plasma wakefield using photon acceleration, supported by extensive particle in cell simulations of a laser pulse that copropagates with a wakefield. The technique can provide the perturbed electron density profile in the laser’s reference frame, averaged over the propagation length, to be accurate within 10%. We discuss the limitations that affect the measurement: small frequency changes, photon trapping, laser displacement, stimulated Raman scattering, and laser beam divergence. By considering these processes, one can determine the optimal parameters of the laser pulse and its propagation length. This new technique allows a characterization of the density perturbation within a plasma wakefield accelerator.

  17. Standardizing CT lung density measure across scanner manufacturers.

    Science.gov (United States)

    Chen-Mayer, Huaiyu Heather; Fuld, Matthew K; Hoppel, Bernice; Judy, Philip F; Sieren, Jered P; Guo, Junfeng; Lynch, David A; Possolo, Antonio; Fain, Sean B

    2017-03-01

    Computed Tomography (CT) imaging of the lung, reported in Hounsfield Units (HU), can be parameterized as a quantitative image biomarker for the diagnosis and monitoring of lung density changes due to emphysema, a type of chronic obstructive pulmonary disease (COPD). CT lung density metrics are global measurements based on lung CT number histograms, and are typically a quantity specifying either the percentage of voxels with CT numbers below a threshold, or a single CT number below which a fixed relative lung volume, nth percentile, falls. To reduce variability in the density metrics specified by CT attenuation, the Quantitative Imaging Biomarkers Alliance (QIBA) Lung Density Committee has organized efforts to conduct phantom studies in a variety of scanner models to establish a baseline for assessing the variations in patient studies that can be attributed to scanner calibration and measurement uncertainty. Data were obtained from a phantom study on CT scanners from four manufacturers with several protocols at various tube potential voltage (kVp) and exposure settings. Free from biological variation, these phantom studies provide an assessment of the accuracy and precision of the density metrics across platforms solely due to machine calibration and uncertainty of the reference materials. The phantom used in this study has three foam density references in the lung density region, which, after calibration against a suite of Standard Reference Materials (SRM) foams with certified physical density, establishes a HU-electron density relationship for each machine-protocol. We devised a 5-step calibration procedure combined with a simplified physical model that enabled the standardization of the CT numbers reported across a total of 22 scanner-protocol settings to a single energy (chosen at 80 keV). A standard deviation was calculated for overall CT numbers for each density, as well as by scanner and other variables, as a measure of the variability, before and after the

  18. TRACTOGRAPHY DENSITY AND NETWORK MEASURES IN ALZHEIMER'S DISEASE.

    Science.gov (United States)

    Prasad, Gautam; Nir, Talia M; Toga, Arthur W; Thompson, Paul M

    2013-04-01

    Brain connectivity declines in Alzheimer's disease (AD), both functionally and structurally. Connectivity maps and networks derived from diffusion-based tractography offer new ways to track disease progression and to understand how AD affects the brain. Here we set out to identify (1) which fiber network measures show greatest differences between AD patients and controls, and (2) how these effects depend on the density of fibers extracted by the tractography algorithm. We computed brain networks from diffusion-weighted images (DWI) of the brain, in 110 subjects (28 normal elderly, 56 with early and 11 with late mild cognitive impairment, and 15 with AD). We derived connectivity matrices and network topology measures, for each subject, from whole-brain tractography and cortical parcellations. We used an ODF lookup table to speed up fiber extraction, and to exploit the full information in the orientation distribution function (ODF). This made it feasible to compute high density connectivity maps. We used accelerated tractography to compute a large number of fibers to understand what effect fiber density has on network measures and in distinguishing different disease groups in our data. We focused on global efficiency, transitivity, path length, mean degree, density, modularity, small world, and assortativity measures computed from weighted and binary undirected connectivity matrices. Of all these measures, the mean nodal degree best distinguished diagnostic groups. High-density fiber matrices were most helpful for picking up the more subtle clinical differences, e.g. between mild cognitively impaired (MCI) and normals, or for distinguishing subtypes of MCI (early versus late). Care is needed in clinical analyses of brain connectivity, as the density of extracted fibers may affect how well a network measure can pick up differences between patients and controls.

  19. First measurements results of the LHC longitudinal density monitor

    CERN Document Server

    Jeff , A; Bravin, E; Boccardi, A; Bozyigit, S; Lefevre, T; Rabiller, A; Roncarolo, F; Welsch, C P; Fisher, A S

    2011-01-01

    Knowledge of the longitudinal distribution of particles is important for various aspects of accelerator operation, for example to check the injection quality and to characterize the development of ghost bunches before and during the physics periods. A new detector, the LHC Longitudinal Density Monitor (LDM) is a single-photon counting system measuring synchrotron light by means of an avalanche photodiode detector. The unprecedented energies reached in the LHC allow synchrotron light diagnostics to be used with both protons and heavy ions. The LDM is able to longitudinally profile the whole ring with a resolution close to the target of 50 ps. On-line correction for the effects of the detector deadtime, pile-up and afterpulsing allow a dynamic range of 105 to be achieved. The LDM operated during the 2010 lead ion run and during 2011 with protons. Measurements from both runs are presented in this contribution along with an analysis of the LDM performance and an outlook for future upgrades.

  20. Precision measurements of Linear Scattering Density using Muon Tomography

    CERN Document Server

    Åström, E; Calliari, I; Calvini, P; Checchia, P; Donzella, A; Faraci, E; Forsberg, F; Gonella, F; Hu, X; Klinger, J; Ödqvist, L S; Pagano, D; Rigoni, A; Ramous, E; Urbani, M; Vanini, S; Zenoni, A; Zumerle, G

    2016-01-01

    We demonstrate that muon tomography can be used to precisely measure the properties of various materials. The materials which have been considered have been extracted from an experimental blast furnace, including carbon (coke) and iron oxides, for which measurements of the linear scattering density relative to the mass density have been performed with an absolute precision of 10%. We report the procedures that are used in order to obtain such precision, and a discussion is presented to address the expected performance of the technique when applied to heavier materials. The results we obtain do not depend on the specific type of material considered and therefore they can be extended to any application.

  1. Precision measurements of linear scattering density using muon tomography

    Science.gov (United States)

    Åström, E.; Bonomi, G.; Calliari, I.; Calvini, P.; Checchia, P.; Donzella, A.; Faraci, E.; Forsberg, F.; Gonella, F.; Hu, X.; Klinger, J.; Sundqvist Ökvist, L.; Pagano, D.; Rigoni, A.; Ramous, E.; Urbani, M.; Vanini, S.; Zenoni, A.; Zumerle, G.

    2016-07-01

    We demonstrate that muon tomography can be used to precisely measure the properties of various materials. The materials which have been considered have been extracted from an experimental blast furnace, including carbon (coke) and iron oxides, for which measurements of the linear scattering density relative to the mass density have been performed with an absolute precision of 10%. We report the procedures that are used in order to obtain such precision, and a discussion is presented to address the expected performance of the technique when applied to heavier materials. The results we obtain do not depend on the specific type of material considered and therefore they can be extended to any application.

  2. Density measurements of compressed-liquid dimethyl ether + pentane mixtures.

    Science.gov (United States)

    Outcalt, Stephanie L; Lemmon, Eric W

    2016-01-01

    Compressed-liquid densities of three compositions of the binary mixture dimethyl ether (CAS No. 115-10-6) + pentane (CAS No. 109-66-0) have been measured with a vibrating U-tube densimeter. Measurements were made at temperatures from 270 K to 390 K with pressures from 1.0 MPa to 50 MPa. The overall combined uncertainty (k=2) of the density data is 0.81 kg·m(-3). Data presented here have been used to improve a previously formulated Helmholtz energy based mixture model. The newly derived parameters are given.

  3. Spectral density matrix of a single photon measured.

    Science.gov (United States)

    Wasilewski, Wojciech; Kolenderski, Piotr; Frankowski, Robert

    2007-09-21

    We propose and demonstrate a method for measuring the spectral density matrix of a single photon pulse. The method is based on registering Hong-Ou-Mandel interference between a photon to be measured and a pair of attenuated and suitably delayed laser pulses described by a known spectral amplitude. The density matrix is retrieved from a two-dimensional interferogram of coincidence counts. The method has been implemented for a type-I down-conversion source, pumped by ultrashort laser pulses. The experimental results agree well with a theoretical model which takes into account the temporal as well as spatial effects in the source.

  4. Spectral density matrix of a single photon measured

    CERN Document Server

    Wasilewski, W; Frankowski, R; Wasilewski, Wojciech; Kolenderski, Piotr; Frankowski, Robert

    2007-01-01

    We propose and demonstrate a method for measuring the spectral density matrix of a single photon pulse. The method is based on registering Hong-Ou-Mandel interference between photon to be measured and a pair of attenuated and suitably delayed laser pulses described by a known spectral amplitude. The density matrix is retrieved from a two-dimensional interferogram of coincidence counts. The method has been implemented for a type-I downconversion source, pumped by ultrashort laser pulses. The experimental results agree well with a theoretical model which takes into account the temporal as well as spatial effects in the source.

  5. Outcomes of bone density measurements in coeliac disease.

    Science.gov (United States)

    Bolland, Mark J; Grey, Andrew; Rowbotham, David S

    2016-01-29

    Some guidelines recommend that patients with newly diagnosed coeliac disease undergo bone density scanning. We assessed the bone density results in a cohort of patients with coeliac disease. We searched bone density reports over two 5-year periods in all patients from Auckland District Health Board (2008-12) and in patients under 65 years from Counties Manukau District Health Board (2009-13) for the term 'coeliac.' Reports for 137 adults listed coeliac disease as an indication for bone densitometry. The average age was 47 years, body mass index (BMI) 25 kg/m(2), and 77% were female. The median time between coeliac disease diagnosis and bone densitometry was 261 days. The average bone density Z-score was slightly lower than expected (Z-score -0.3 to 0.4) at the lumbar spine, total hip and femoral neck, but 88-93% of Z-scores at each site lay within the normal range. Low bone density was strongly related to BMI: the proportions with Z-score 30 kg/m(2) were 28%, 15%, 6% and 0% respectively. Average bone density was normal, suggesting that bone density measurement is not indicated routinely in coeliac disease, but could be considered on a case-by-case basis for individuals with strong risk factors for fracture.

  6. Comparison of bone density measurement techniques: DXA and Archimedes' principle.

    Science.gov (United States)

    Keenan, M J; Hegsted, M; Jones, K L; Delany, J P; Kime, J C; Melancon, L E; Tulley, R T; Hong, K D

    1997-11-01

    The standard method for determination of density (g/cm3) of bones from small animals has been the application of Archimedes' principle. A recent development has been software for the determination of "density" (g/cm2) of small animal bones with dual-energy X-ray absorptiometry (DXA). We compared Archimedes' principle and DXA (Hologic QDR-2000) in the measurement of the densities of whole and hollowed femurs of 5- to 6-month-old retired female breeder rats. In an attempt to ensure detectable treatment differences, rats were used from a low-vitamin D Holtzman and a supplemental-vitamin D Sprague-Dawley colony. Whole femur densities were higher for supplemental-vitamin D colony rats than for low vitamin D rats using both techniques (Archimedes' principle, p Archimedes' principle than for DXA. Other variables such as femur ash weight and calcium content were also highly correlated to densities with both techniques. Hollowed femur density values were higher than whole femur values with Archimedes' principle but lower with DXA. Colony effects for hollowed femur densities were diminished with Archimedes' principle (p < 0.03) and eliminated with DXA (p < 0.53). Investigation of whole bones is more biologically relevant, and both techniques were effective in detecting differences between whole femurs from low-vitamin D and supplemental-vitamin D colony rats.

  7. A microwave interferometer for small and tenuous plasma density measurements.

    Science.gov (United States)

    Tudisco, O; Lucca Fabris, A; Falcetta, C; Accatino, L; De Angelis, R; Manente, M; Ferri, F; Florean, M; Neri, C; Mazzotta, C; Pavarin, D; Pollastrone, F; Rocchi, G; Selmo, A; Tasinato, L; Trezzolani, F; Tuccillo, A A

    2013-03-01

    The non-intrusive density measurement of the thin plasma produced by a mini-helicon space thruster (HPH.com project) is a challenge, due to the broad density range (between 10(16) m(-3) and 10(19) m(-3)) and the small size of the plasma source (2 cm of diameter). A microwave interferometer has been developed for this purpose. Due to the small size of plasma, the probing beam wavelength must be small (λ = 4 mm), thus a very high sensitivity interferometer is required in order to observe the lower density values. A low noise digital phase detector with a phase noise of 0.02° has been used, corresponding to a density of 0.5 × 10(16) m(-3).

  8. A microwave interferometer for small and tenuous plasma density measurements

    Energy Technology Data Exchange (ETDEWEB)

    Tudisco, O.; Falcetta, C.; De Angelis, R.; Florean, M.; Neri, C.; Mazzotta, C.; Pollastrone, F.; Rocchi, G.; Tuccillo, A. A. [ENEA CR Frascati, Via E. Fermi 45, 00044 Frascati (Italy); Lucca Fabris, A.; Manente, M.; Ferri, F.; Tasinato, L.; Trezzolani, F. [CISAS ' G.Colombo,' Universita degli studi di Padova, Via Venezia 15, 35131 Padova (Italy); Accatino, L. [ACC Antenna and MW tech, Via Trieste 16/B, 10098 Rivoli (Italy); Pavarin, D. [Dip. di Ingegneria Industriale (DII), Universita degli Studi di Padova, Via Venezia 1, 35131 Padova (Italy); Selmo, A. [RESIA, Studio Progettazione e Realizzazione di Apparati Elettronici, via Roma 17, 37041 Albaredo d' Adige (Italy)

    2013-03-15

    The non-intrusive density measurement of the thin plasma produced by a mini-helicon space thruster (HPH.com project) is a challenge, due to the broad density range (between 10{sup 16} m{sup -3} and 10{sup 19} m{sup -3}) and the small size of the plasma source (2 cm of diameter). A microwave interferometer has been developed for this purpose. Due to the small size of plasma, the probing beam wavelength must be small ({lambda}= 4 mm), thus a very high sensitivity interferometer is required in order to observe the lower density values. A low noise digital phase detector with a phase noise of 0.02 Degree-Sign has been used, corresponding to a density of 0.5 Multiplication-Sign 10{sup 16} m{sup -3}.

  9. Flux density calibration in diffuse optical tomographic systems.

    Science.gov (United States)

    Biswas, Samir Kumar; Rajan, Kanhirodan; Vasu, Ram M

    2013-02-01

    The solution of the forward equation that models the transport of light through a highly scattering tissue material in diffuse optical tomography (DOT) using the finite element method gives flux density (Φ) at the nodal points of the mesh. The experimentally measured flux (Umeasured) on the boundary over a finite surface area in a DOT system has to be corrected to account for the system transfer functions (R) of various building blocks of the measurement system. We present two methods to compensate for the perturbations caused by R and estimate true flux density (Φ) from Umeasuredcal. In the first approach, the measurement data with a homogeneous phantom (Umeasuredhomo) is used to calibrate the measurement system. The second scheme estimates the homogeneous phantom measurement using only the measurement from a heterogeneous phantom, thereby eliminating the necessity of a homogeneous phantom. This is done by statistically averaging the data (Umeasuredhetero) and redistributing it to the corresponding detector positions. The experiments carried out on tissue mimicking phantom with single and multiple inhomogeneities, human hand, and a pork tissue phantom demonstrate the robustness of the approach.

  10. Improved measurement of ice layer density in seasonal snowpacks

    Directory of Open Access Journals (Sweden)

    T. Watts

    2015-11-01

    Full Text Available Ice layers in snowpacks introduce uncertainty in satellite derived estimates of snow water equivalent, have ecological impacts on plants and animals, and change the thermal and vapour transport properties of the snowpack. The microstructure and specifically the density of ice layers is poorly quantified. Here we present a new field method, for measuring the density of ice layers caused by melt or rain-on-snow events. The method was used on 87 ice layer samples in the Canadian Arctic and mid-latitudes; the mean measured ice layer density was 909 ± 18 kg m−3 with a standard deviation of 23 kg m−3, significantly higher than values typically used in the literature.

  11. Urinary density measurement and analysis methods in neonatal unit care

    Directory of Open Access Journals (Sweden)

    Maria Vera Lúcia Moreira Leitão Cardoso

    2013-09-01

    Full Text Available The objective was to assess urine collection methods through cotton in contact with genitalia and urinary collector to measure urinary density in newborns. This is a quantitative intervention study carried out in a neonatal unit of Fortaleza-CE, Brazil, in 2010. The sample consisted of 61 newborns randomly chosen to compose the study group. Most neonates were full term (31/50.8% males (33/54%. Data on urinary density measurement through the methods of cotton and collector presented statistically significant differences (p<0.05. The analysis of interquartile ranges between subgroups resulted in statistical differences between urinary collector/reagent strip (1005 and cotton/reagent strip (1010, however there was no difference between urinary collector/ refractometer (1008 and cotton/ refractometer. Therefore, further research should be conducted with larger sampling using methods investigated in this study and whenever possible, comparing urine density values to laboratory tests.

  12. Quantitative measurement of the orbital angular momentum density of light

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2012-03-01

    Full Text Available In this work we derive expressions for the orbital angular momentum (OAM) density of light, for both symmetric and nonsymmetric optical fields, that allow a direct comparison between theory and experiment. We present a simple method for measuring...

  13. Measurement of D-region electron density by partial reflections

    Science.gov (United States)

    Olsen, R. O.; Mott, D. L.; Gammill, B. G.

    1978-01-01

    Measurements of electron density in the lower ionosphere were made at White Sands Missile Range throughout the STRATCOM VIII launch day using a partial-reflection sounder. Information regarding the sounder's antenna pattern was gained from the passage of the balloon over the array.

  14. Current Density Measurements of an Annular-Geometry Ion Engine

    Science.gov (United States)

    Shastry, Rohit; Patterson, Michael J.; Herman, Daniel A.; Foster, John E.

    2012-01-01

    The concept of the annular-geometry ion engine, or AGI-Engine, has been shown to have many potential benefits when scaling electric propulsion technologies to higher power. However, the necessary asymmetric location of the discharge cathode away from thruster centerline could potentially lead to non-uniformities in the discharge not present in conventional geometry ion thrusters. In an effort to characterize the degree of this potential nonuniformity, a number of current density measurements were taken on a breadboard AGI-Engine. Fourteen button probes were used to measure the ion current density of the discharge along a perforated electrode that replaced the ion optics during conditions of simulated beam extraction. Three Faraday probes spaced apart in the vertical direction were also used in a separate test to interrogate the plume of the AGI-Engine during true beam extraction. It was determined that both the discharge and the plume of the AGI-Engine are highly uniform, with variations under most conditions limited to 10% of the average current density in the discharge and 5% of the average current density in the plume. Beam flatness parameter measured 30 mm from the ion optics ranged from 0.85 0.95, and overall uniformity was shown to generally increase with increasing discharge and beam currents. These measurements indicate that the plasma is highly uniform despite the asymmetric location of the discharge cathode.

  15. One versus Two Breast Density Measures to Predict 5- and 10-Year Breast Cancer Risk.

    Science.gov (United States)

    Kerlikowske, Karla; Gard, Charlotte C; Sprague, Brian L; Tice, Jeffrey A; Miglioretti, Diana L

    2015-06-01

    One measure of Breast Imaging Reporting and Data System (BI-RADS) breast density improves 5-year breast cancer risk prediction, but the value of sequential measures is unknown. We determined whether two BI-RADS density measures improve the predictive accuracy of the Breast Cancer Surveillance Consortium 5-year risk model compared with one measure. We included 722,654 women of ages 35 to 74 years with two mammograms with BI-RADS density measures on average 1.8 years apart; 13,715 developed invasive breast cancer. We used Cox regression to estimate the relative hazards of breast cancer for age, race/ethnicity, family history of breast cancer, history of breast biopsy, and one or two density measures. We developed a risk prediction model by combining these estimates with 2000-2010 Surveillance, Epidemiology, and End Results incidence and 2010 vital statistics for competing risk of death. The two-measure density model had marginally greater discriminatory accuracy than the one-measure model (AUC, 0.640 vs. 0.635). Of 18.6% of women (134,404 of 722,654) who decreased density categories, 15.4% (20,741 of 134,404) of women whose density decreased from heterogeneously or extremely dense to a lower density category with one other risk factor had a clinically meaningful increase in 5-year risk from breast cancer risk and improves risk classification for women with risk factors and a decrease in density. A two-density model should be considered for women whose density decreases when calculating breast cancer risk. ©2015 American Association for Cancer Research.

  16. Measuring the Densities of Aqueous Glasses at Cryogenic Temperatures.

    Science.gov (United States)

    Shen, Chen; Julius, Ethan F; Tyree, Timothy J; Dan, Ritwik; Moreau, David W; Thorne, Robert

    2017-06-28

    We demonstrate a method for determining the vitreous phase cryogenic temperature densities of aqueous mixtures, and other samples that require rapid cooling, to prepare the desired cryogenic temperature phase. Microliter to picoliter size drops are cooled by projection into a liquid nitrogen-argon (N2-Ar) mixture. The cryogenic temperature phase of the drop is evaluated using a visual assay that correlates with X-ray diffraction measurements. The density of the liquid N2-Ar mixture is adjusted by adding N2 or Ar until the drop becomes neutrally buoyant. The density of this mixture and thus of the drop is determined using a test mass and Archimedes principle. With appropriate care in drop preparation, management of gas above the liquid cryogen mixture to minimize icing, and regular mixing of the cryogenic mixture to prevent density stratification and phase separation, densities accurate to <0.5% of drops as small as 50 pL can readily be determined. Measurements on aqueous cryoprotectant mixtures provide insight into cryoprotectant action, and provide quantitative data to facilitate thermal contraction matching in biological cryopreservation.

  17. Measurement System Reliability Assessment

    Directory of Open Access Journals (Sweden)

    Kłos Ryszard

    2015-06-01

    Full Text Available Decision-making in problem situations is based on up-to-date and reliable information. A great deal of information is subject to rapid changes, hence it may be outdated or manipulated and enforce erroneous decisions. It is crucial to have the possibility to assess the obtained information. In order to ensure its reliability it is best to obtain it with an own measurement process. In such a case, conducting assessment of measurement system reliability seems to be crucial. The article describes general approach to assessing reliability of measurement systems.

  18. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Acharya, Viral V.; Heje Pedersen, Lasse; Philippon, Thomas

    We present a simple model of systemic risk and we show that each financial institution's contribution to systemic risk can be measured as its systemic expected shortfall (SES), i.e., its propensity to be undercapitalized when the system as a whole is undercapitalized. SES increases...... with the institution's leverage and with its expected loss in the tail of the system's loss distribution. Institutions internalize their externality if they are ‘taxed’ based on their SES. We demonstrate empirically the ability of SES to predict emerging risks during the financial crisis of 2007-2009, in particular...

  19. DIFFUSE MOLECULAR CLOUD DENSITIES FROM UV MEASUREMENTS OF CO ABSORPTION

    Energy Technology Data Exchange (ETDEWEB)

    Goldsmith, Paul F. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States)

    2013-09-10

    We use UV measurements of interstellar CO toward nearby stars to calculate the density in the diffuse molecular clouds containing the molecules responsible for the observed absorption. Chemical models and recent calculations of the excitation rate coefficients indicate that the regions in which CO is found have hydrogen predominantly in molecular form and that collisional excitation is by collisions with H{sub 2} molecules. We carry out statistical equilibrium calculations using CO-H{sub 2} collision rates to solve for the H{sub 2} density in the observed sources without including effects of radiative trapping. We have assumed kinetic temperatures of 50 K and 100 K, finding this choice to make relatively little difference to the lowest transition. For the sources having T{sup ex}{sub 10} only for which we could determine upper and lower density limits, we find (n(H{sub 2})) = 49 cm{sup -3}. While we can find a consistent density range for a good fraction of the sources having either two or three values of the excitation temperature, there is a suggestion that the higher-J transitions are sampling clouds or regions within diffuse molecular cloud material that have higher densities than the material sampled by the J = 1-0 transition. The assumed kinetic temperature and derived H{sub 2} density are anticorrelated when the J = 2-1 transition data, the J = 3-2 transition data, or both are included. For sources with either two or three values of the excitation temperature, we find average values of the midpoint of the density range that is consistent with all of the observations equal to 68 cm{sup -3} for T{sup k} = 100 K and 92 cm{sup -3} for T{sup k} = 50 K. The data for this set of sources imply that diffuse molecular clouds are characterized by an average thermal pressure between 4600 and 6800 K cm{sup -3}.

  20. Microsecond resolved electron density measurements with a hairpin resonator probe in a pulsed ICP discharge

    CERN Document Server

    Peterson, David; Larson, Lynda; Shannon, Steven

    2016-01-01

    Time resolved electron density measurements in pulsed RF discharges are shown using a hairpin resonance probe using low cost electronics, on par with normal Langmuir probe boxcar mode operation. Time resolution of less than one microsecond has been demonstrated. A signal generator produces the applied microwave frequency; the reflected waveform is passed through a directional coupler and filtered to remove the RF component. The signal is heterodyned with a frequency mixer and read by an oscilloscope. At certain points during the pulse, the plasma density is such that the applied frequency is the same as the resonance frequency of the probe/plasma system, creating a dip in the reflected signal. The applied microwave frequency is shifted in small increments in a frequency boxcar routine to determine the density as a function of time. The system uses a grounded probe to produce low cost, high fidelity, and highly reproducible electron density measurements that can work in harsh chemical environments. Measurement...

  1. Density Fluctuation Measurements Using FIR Interferometer on HL-2A Tokamak

    Institute of Scientific and Technical Information of China (English)

    ZHOU Yan; PENG Bei-Bin; YANG Qing-wei; DUAN Xu-Ru; DING Xuan-Tong; LI Lian-Cai; LI Yong-Gao; JIAO Yi-Ming; DENG Zhong-Chao; YI Jiang; LIU Yi; ZHAO Kai-Jun; JI Xiao-Quan

    2008-01-01

    Denity fluctuations were first measured in the core region of HL-2A tokamak plasma using a newly developed multi-channel FIR interferometer system. In divertor ohmic discharges, we measured the radial density fluctuation levels of 5%, which increase to 10-20% during the appearance of MHD activity. Most of the power density in the density fluctuation spectrum is directly associated with m=2 tearing modes. The fluctuation levels reduce to 1/3 and plasma confinement is improved during off-axis electron-cyclotron-resonance heating (ECRH).Supported by the National Natural Science Foundation of China under Grant Nos 10575030 and 10675043.

  2. Pulse compression radar reflectometry for density measurements on fusion plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Costley, A.; Prentice, R. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Laviron, C. [Compagnie Generale des Matieres Nucleaires (COGEMA), 78 - Velizy-Villacoublay (France); Prentice, R. [Toulouse-3 Univ., 31 (France). Centre d`Etude Spatiale des Rayonnements

    1994-07-01

    On tokamaks and other toroidal machines, reflectometry is a very rapidly developing technique for density profile measurements, particularly near the edge. Its principle relies on the total reflection of an electromagnetic wave at a cutoff layer, where the critical density is reached and the local refractive index goes to zero. With the new fast frequency synthesizers now available, a method based on pulse compression radar is proposed for plasma reflectometry, overcoming the limitations of the previous reflectometry methods. The measurement can be made on a time-scale which is effectively very short relatively to the plasma fluctuations, and the very high reproducibility and stability of the source allows an absolute calibration of the waveguides to be made, which corrects for the effects of the parasitic reflections. 2 refs., 5 figs.

  3. Two dimensional density and its fluctuation measurements by using phase imaging method in GAMMA 10

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, M.; Negishi, S.; Shima, Y.; Hojo, H.; Imai, T. [Plasma Research Center, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8577 (Japan); Mase, A. [Kyushu University, 6-1 Kasuga-koen, Kasuga, Fukuoka 816-8580 (Japan); Kogi, Y. [Fukuoka Institute of Technology, 3-30-1 Wajiro-higashi, Higashiku, Fukuoka 811-0295 (Japan)

    2010-10-15

    Two dimensional (2D) plasma image analysis is useful to study the improvement of plasma confinement in magnetically confined fusion plasmas. We have constructed a 2D interferometer system with phase imaging method for studying 2D plasma density distribution and its fluctuation measurement in the tandem mirror GAMMA 10. 2D profiles of electron density and its fluctuation have been successfully obtained by using this 2D phase imaging system. We show that 2D plasma density and fluctuation profiles clearly depends on the axial confining potential formation with application of plug electron cyclotron heating in GAMMA 10.

  4. Plasma actuator electron density measurement using microwave perturbation method

    Energy Technology Data Exchange (ETDEWEB)

    Mirhosseini, Farid; Colpitts, Bruce [Electrical and Computer Engineering, University of New Brunswick, Fredericton, New Brunswick E3B 5A3 (Canada)

    2014-07-21

    A cylindrical dielectric barrier discharge plasma under five different pressures is generated in an evacuated glass tube. This plasma volume is located at the center of a rectangular copper waveguide cavity, where the electric field is maximum for the first mode and the magnetic field is very close to zero. The microwave perturbation method is used to measure electron density and plasma frequency for these five pressures. Simulations by a commercial microwave simulator are comparable to the experimental results.

  5. EPR measurement and the origin of cosmic density fluctuations

    Directory of Open Access Journals (Sweden)

    Morikawa Masahiro

    2014-04-01

    Full Text Available We explore consistent application of quantum mechanics to the objects in the Universe and in laboratories. The measurement dynamics in quantum mechanics is modeled as a physical process of spontaneous symmetry breaking (SSB which is described by the generalized effective action method. A violation of the Bell inequality is observed in this model and the generation of the density fluctuations in the early Universe is described as the SSB process of the spatially translational symmetry.

  6. An ultracold neutron storage bottle for UCN density measurements

    CERN Document Server

    Bison, G; Daum, M; Kirch, K; Krempel, J; Lauss, B; Meier, M; Ries, D; Schmidt-Wellenburg, P; Zsigmond, G

    2016-01-01

    We have developed a storage bottle for ultracold neutrons (UCN) in order to measure the UCN density at the beamports of the Paul Scherrer Institute's (PSI) UCN source. This paper describes the design, construction and commissioning of the robust and mobile storage bottle with a volume comparable to typical storage experiments 32 liter e.g. searching for an electric dipole moment of the neutron.

  7. An ultracold neutron storage bottle for UCN density measurements

    Energy Technology Data Exchange (ETDEWEB)

    Bison, G.; Burri, F.; Daum, M. [Paul Scherrer Institute (PSI), CH-5232 Villigen PSI (Switzerland); Kirch, K. [Paul Scherrer Institute (PSI), CH-5232 Villigen PSI (Switzerland); Institute for Particle Physics, Eidgenössische Technische Hochschule (ETH), Zürich (Switzerland); Krempel, J. [Institute for Particle Physics, Eidgenössische Technische Hochschule (ETH), Zürich (Switzerland); Lauss, B., E-mail: bernhard.lauss@psi.ch [Paul Scherrer Institute (PSI), CH-5232 Villigen PSI (Switzerland); Meier, M. [Paul Scherrer Institute (PSI), CH-5232 Villigen PSI (Switzerland); Ries, D., E-mail: dieter.ries@psi.ch [Paul Scherrer Institute (PSI), CH-5232 Villigen PSI (Switzerland); Institute for Particle Physics, Eidgenössische Technische Hochschule (ETH), Zürich (Switzerland); Schmidt-Wellenburg, P.; Zsigmond, G. [Paul Scherrer Institute (PSI), CH-5232 Villigen PSI (Switzerland)

    2016-09-11

    We have developed a storage bottle for ultracold neutrons (UCNs) in order to measure the UCN density at the beamports of the Paul Scherrer Institute's (PSI) UCN source. This paper describes the design, construction and commissioning of the robust and mobile storage bottle with a volume comparable to typical storage experiments (32 L) e.g. searching for an electric dipole moment of the neutron.

  8. Microwave/Sonic Apparatus Measures Flow and Density in Pipe

    Science.gov (United States)

    Arndt, G. D.; Ngo, Phong; Carl, J. R.; Byerly, Kent A.

    2004-01-01

    An apparatus for measuring the rate of flow and the mass density of a liquid or slurry includes a special section of pipe instrumented with microwave and sonic sensors, and a computer that processes digitized readings taken by the sensors. The apparatus was conceived specifically for monitoring a flow of oil-well-drilling mud, but the basic principles of its design and operation are also applicable to monitoring flows of other liquids and slurries.

  9. Bone mineral density measurement over the shoulder region

    DEFF Research Database (Denmark)

    Doetsch, A M; Faber, J; Lynnerup, N

    2002-01-01

    The purpose of this study was to (1). establish a method for measuring bone mineral density (BMD) over the shoulder region; (2). compare the relationship between shoulder BMD levels with hip BMD and body mass index (BMI); and (3). discuss the relevance of the shoulder scan as an early indicator...... to the least relative influence of weight and stress loading because of migration of calcium to weight and stress-bearing areas. Since the effect of this migration could mask local osteoporotic bone loss, shoulder BMD measurement is likely to minimize false indicators of healthy bone in women with high BMI...

  10. Reflectometry techniques for density profile measurements on fusion plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Laviron, C. [Association Euratom-CEA, Centre d`Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Donne, A.J.H. [Associatie Euratom-FOM, Nieuwegein (Netherlands). FOM-Instituut voor Plasmafysica; Manso, M.E. [Instituto Superior Tecnico, Lisbon (Portugal). Lab. de Quimica Organica; Sanchez, J. [EURATOM-CIEMAT for Fusion Association, Madrid (Spain)

    1996-03-01

    Reflectometry applied to the measurement of density profiles on fusion plasmas has been subject to many recent developments. After a brief reminder of the principles of reflectometry, the theoretical accuracy of reflectometry measurements is discussed. The main difficulties limiting the performance, namely the plasma fluctuations and the quality of the transmission lines, are analysed. The different techniques used for reflectometry are then presented. The present status and achievements of actual implementations of these techniques are shown, with an analysis of their respective limitations and merits, as well as foreseen developments. (author). 70 refs.

  11. A molecular Rayleigh scattering setup to measure density fluctuations in thermal boundary layers

    Science.gov (United States)

    Panda, J.

    2016-12-01

    A Rayleigh scattering-based density fluctuation measurement system was set up inside a low-speed wind tunnel of NASA Ames Research Center. The immediate goal was to study the thermal boundary layer on a heated flat plate. A large number of obstacles had to be overcome to set up the system, such as the removal of dust particles using air filters, the use of photoelectron counting electronics to measure low intensity light, an optical layout to minimize stray light contamination, the reduction in tunnel vibration, and an expanded calibration process to relate photoelectron arrival rate to air density close to the plate surface. To measure spectra of turbulent density fluctuations, a two-PMT cross-correlation system was used to minimize the shot noise floor. To validate the Rayleigh measurements, temperature fluctuations spectra were calculated from density spectra and then compared with temperature spectra measured with a cold-wire probe operated in constant current mode. The spectra from the downstream half of the plate were found to be in good agreement with cold-wire probe, whereas spectra from the leading edge differed. Various lessons learnt are discussed. It is believed that the present effort is the first measurement of density fluctuations spectra in a boundary layer flow.

  12. Multifractal analysis of high resolution solar wind proton density measurements

    Science.gov (United States)

    Sorriso-Valvo, Luca; Carbone, Francesco; Leonardis, Ersilia; Chen, Christopher H. K.; Šafránková, Jana; Němeček, Zdenek

    2017-03-01

    The solar wind is a highly turbulent medium, with a high level of field fluctuations throughout a broad range of scales. These include an inertial range where a turbulent cascade is assumed to be active. The solar wind cascade shows intermittency, which however may depend on the wind conditions. Recent observations have shown that ion-scale magnetic turbulence is almost self-similar, rather than intermittent. A similar result was observed for the high resolution measurements of proton density provided by the spacecraft Spektr-R. Intermittency may be interpreted as the result of the multifractal properties of the turbulent cascade. In this perspective, this paper is devoted to the description of the multifractal properties of the high resolution density measurements. In particular, we have used the standard coarse-graining technique to evaluate the generalized dimensions Dq , and from these the multifractal spectrum f (α) , in two ranges of scale. A fit with the p-model for intermittency provided a quantitative measure of multifractality. Such indicator was then compared with alternative measures: the width of the multifractal spectrum, the peak of the kurtosis, and its scaling exponent. The results indicate that the small-scale fluctuations are multifractal, and suggest that different measures of intermittency are required to fully understand the small scale cascade.

  13. A monochromatic x-ray imaging system for characterizing low-density foams

    Energy Technology Data Exchange (ETDEWEB)

    Lanier, Nicholas E. [Los Alamos National Laboratory; Taccetti, Jose M. [Los Alamos National Laboratory; Hamilton, Christopher E. [Los Alamos National Laboratory

    2012-05-04

    In High Energy Density (HED) laser experiments, targets often require small, low-density, foam components. However, their limited size can preclude single component characterization, forcing one to rely solely on less accurate bulk measurements. We have developed a monochromatic imaging a system to characterize both the density and uniformity of single component low-mass foams. This x-ray assembly is capable of determining line-averaged density variations near the 1% level, and provides statistically identical results to those obtained at the Brookhaven's NSLS. This system has the added benefit of providing two-dimensional density data, allowing an assessment of density uniformity.

  14. Measurement of bone mineral density in patients with psoriasis vulgaris

    Directory of Open Access Journals (Sweden)

    Nurgül Köse

    2013-12-01

    Full Text Available Objective: The aim of this study was to determine thechanges of bone mineral density in patients with psoriasisvulgaris.Methods: 33 patients, diagnosed with psoriasis vulgarisin Erciyes University, Medical School, Department of Dermatology,and 23 healthy subjects as control group wereincluded in this study. Lumbar and femur bone mineraldensity of all patients and control group were measured.Biochemical tests related to bone metabolism were performed.Results: We did not find statistically significant differencebetween patient and control groups’ bone mineral density.However, the lumbar spine t score of men, were found tobe significantly lower in the patient group than the controlgroup (p<0.05. There was no statistically significant differencein bone mineral density of women between thepatient and control groups. The effects on bone mineraldensity of disease period and using the topical corticosteroidswere not statistically significant.Conclusion: Our study indicates that bone mineral densityof patients with psoriasis vulgaris was not differentfrom healthy subject.Key words: Psoriasis vulgaris, bone mineral density, osteoporosis

  15. Neutralino relic density from ILC measurements in the CPV MSSM

    CERN Document Server

    Bélanger, G; Kraml, Sabine; Martyn, H -U; Pukhov, A

    2008-01-01

    We discuss ILC measurements for a specific MSSM scenario with CP phases, where the lightest neutralino is a good candidate for dark matter, annihilating efficiently through t-channel exchange of light staus. These prospective (CP-even) ILC measurements are then used to fit the underlying model parameters. A collider prediction of the relic density of the neutralino from this fit gives 0.116measurements of electric dipole moments is also discussed. Finally we comment on collider measurements at higher energies for refining the prediction of Omega h^2.

  16. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Heje Pedersen, Lasse

    We present a simple model of systemic risk and we show that each financial institution’s contribution to systemic risk can be measured as its systemic expected shortfall (SES), i.e., its propensity to be undercapitalized when the system as a whole is undercapitalized. SES increases...... with the institution’s leverage and with its expected loss in the tail of the system’s loss distribution. Institutions internalize their externality if they are “taxed” based on their SES. We demonstrate empirically the ability of SES to predict emerging risks during the financial crisis of 2007-2009, in particular......, (i) the outcome of stress tests performed by regulators; (ii) the decline in equity valuations of large financial firms in the crisis; and, (iii) the widening of their credit default swap spreads....

  17. Calorimetric measuring systems

    DEFF Research Database (Denmark)

    Ritchie, Andrew Ewen; Pedersen, John Kim; Blaabjerg, Frede

    2004-01-01

    the system cooling requirement. A common problem is that high-frequency phenomena like proximity effect, skin effect, hysteresis losses, and eddy current losses appear in the systems. These losses are very difficult to treat both theoretically and in practice. It is often difficult to measure the effect......Power Electronics remains an emerging technology. New materials, new devices, and new circuit topologies reduce the cost, weight, and volume for important applications [1]. Two important factors in power electronic circuits are the switching speed of the devices and the total power losses...... in the system. If the switching speed can be increased, improvements may be possible (e.g., current ripple in an electrical machine or physical size of passive components may be reduced). On the other hand, increased switching speed may cause additional losses in a power electronic system and increase...

  18. Development and application of diagnostic instrumentation for measurement of electron density and conductivity

    Energy Technology Data Exchange (ETDEWEB)

    Bauman, L.E.

    1990-05-01

    The purpose of this contract was to assemble and demonstrate in the laboratory a Faraday rotation system for measurement of electron density and conductivity, with the intent to produce a system suitable for diagnostic support of the development of pulsed, space-based magnetohydrodynamic (MHD) power systems. Two system configurations were tested: (1) a rotating polarizer and (2) a beam splitting polarizer. Due to the short path length plasma produced in the laboratory flame, the long wavelength 496 {mu}m methyl fluoride laser line was used and only the more sensitive rotating polarizer configuration was used for the demonstration experiments. Electron number densities from 2 {times} 10{sup 19} to 9 {times} 10{sup 19} were measured with good agreement to statistical equilibrium (Saha) calculations using emission absorption-measured flame temperatures and neutral seed atom number seed atom nuclear densities. The electron collision frequencies were measured by transmission measurements. Combining these two measurements gave measured electron conductivities of between 4 and 12 mohs/m. These results compared reasonably well with those found with an electron collision frequency model combined with chemical equilibrium calculations and the emission absorption measurements. Ellipticity measurements of electron collision frequency were not possible due to the short path length of the laboratory plasma. 46 refs., 25 figs., 9 tabs.

  19. Enterprise performance measurement systems

    Directory of Open Access Journals (Sweden)

    Milija Bogavac

    2014-10-01

    Full Text Available Performance measurement systems are an extremely important part of the control and management actions, because in this way a company can determine its business potential, its market power, potential and current level of business efficiency. The significance of measurement consists in influencing the relationship between the results of reproduction (total volume of production, value of production, total revenue and profit and investments to achieve these results (factors of production spending and hiring capital in order to achieve the highest possible quality of the economy. (The relationship between the results of reproduction and investment to achieve them quantitatively determines economic success as the quality of the economy. Measuring performance allows the identification of the economic resources the company has, so looking at the key factors that affect its performance can help to determine the appropriate course of action.

  20. Wireless Acoustic Measurement System

    Science.gov (United States)

    Anderson, Paul D.; Dorland, Wade D.; Jolly, Ronald L.

    2007-01-01

    A prototype wireless acoustic measurement system (WAMS) is one of two main subsystems of the Acoustic Prediction/ Measurement Tool, which comprises software, acoustic instrumentation, and electronic hardware combined to afford integrated capabilities for predicting and measuring noise emitted by rocket and jet engines. The other main subsystem is described in the article on page 8. The WAMS includes analog acoustic measurement instrumentation and analog and digital electronic circuitry combined with computer wireless local-area networking to enable (1) measurement of sound-pressure levels at multiple locations in the sound field of an engine under test and (2) recording and processing of the measurement data. At each field location, the measurements are taken by a portable unit, denoted a field station. There are ten field stations, each of which can take two channels of measurements. Each field station is equipped with two instrumentation microphones, a micro- ATX computer, a wireless network adapter, an environmental enclosure, a directional radio antenna, and a battery power supply. The environmental enclosure shields the computer from weather and from extreme acoustically induced vibrations. The power supply is based on a marine-service lead-acid storage battery that has enough capacity to support operation for as long as 10 hours. A desktop computer serves as a control server for the WAMS. The server is connected to a wireless router for communication with the field stations via a wireless local-area network that complies with wireless-network standard 802.11b of the Institute of Electrical and Electronics Engineers. The router and the wireless network adapters are controlled by use of Linux-compatible driver software. The server runs custom Linux software for synchronizing the recording of measurement data in the field stations. The software includes a module that provides an intuitive graphical user interface through which an operator at the control server

  1. Temperature and Density Measurements in a Quiet Coronal Streamer

    Science.gov (United States)

    Warren, Harry P.; Warshall, Andrew D.

    2002-06-01

    Many previous studies have used emission line or broadband filter ratios to infer the presence of temperature gradients in the quiet solar corona. Recently it has been suggested that these temperature gradients are not real, but result from the superposition of isothermal loops with different temperatures and density scale heights along the line of sight. A model describing this hydrostatic weighting bias has been developed by Aschwanden & Acton. In this paper we present the application of the Aschwanden & Acton differential emission measure model to Solar and Heliospheric Observatory Solar Ultraviolet Measurement of Emitted Radiation (SUMER) observations of a quiet coronal streamer. Simultaneous Yohkoh soft X-ray telescope (SXT) observations show increases in the filter ratios with height above the limb, indicating an increase in temperature. The application of the Aschwanden & Acton model to these SUMER data, however, show that the temperature is constant with height and that the distribution of temperatures in the corona is much too narrow for the hydrostatic weighting bias to have any effect on the SXT filter ratios. We consider the possibility that there is a tenuous hot component (~3 MK) that accounts for the SXT observations. We find that a hot plasma with an emission measure sufficient to reproduce the observed SXT fluxes would also produce significant count rates in the high-temperature emission lines in the SUMER wavelength range. These lines are not observed, and we conclude that the SUMER spectra are not consistent with the SXT filter ratio temperatures. Calculations from a hydrodynamic loop model suggest that nonuniform footpoint heating may be consistent with the temperatures and densities observed at most heights, consistent with the recent analysis of relatively cool (~1 MK) active region loops. We also find, however, that at the lowest heights the observed densities are smaller than those predicted by uniform or footpoint heating.

  2. Multicomponent density-functional theory for time-dependent systems

    NARCIS (Netherlands)

    Butriy, O.; Ebadi, H.; de Boeij, P. L.; van Leeuwen, R.; Gross, E. K. U.

    2007-01-01

    We derive the basic formalism of density functional theory for time-dependent electron-nuclear systems. The basic variables of this theory are the electron density in body-fixed frame coordinates and the diagonal of the nuclear N-body density matrix. The body-fixed frame transformation is carried ou

  3. Current density distribution mapping in PEM fuel cells as an instrument for operational measurements

    Energy Technology Data Exchange (ETDEWEB)

    Geske, M.; Heuer, M.; Heideck, G.; Styczynski, Z. A. [Otto-von-Guericke University Magdeburg, Chair Electric Power Networks and Renewable Energy Sources, Magdeburg (Germany)

    2010-07-01

    A newly developed measurement system for current density distribution mapping has enabled a new approach for operational measurements in proton exchange membrane fuel cells (PEMFC). Taking into account previously constructed measurement systems, a method based on a multi layer printed circuit board was chosen for the development of the new system. This type of system consists of a sensor, a special electronic device and the control and visualization PC. For the acquisition of the current density distribution values, a sensor device was designed and installed within a multilayer printed circuit board with integrated shunt resistors. Varying shunt values can be taken into consideration with a newly developed and evaluated calibration method. The sensor device was integrated in a PEM fuel cell stack to prove the functionality of the whole measurement system. A software application was implemented to visualize and save the measurement values. Its functionality was verified by operational measurements within a PEMFC system. Measurement accuracy and possible negative reactions of the sensor device during PEMFC operation are discussed in detail in this paper. The developed system enables operational measurements for different operating phases of PEM fuel cells. Additionally, this can be seen as a basis for new opportunities of optimization for fuel cell design and operation modes. (author)

  4. Current Density Distribution Mapping in PEM Fuel Cells as An Instrument for Operational Measurements

    Directory of Open Access Journals (Sweden)

    Martin Geske

    2010-04-01

    Full Text Available A newly developed measurement system for current density distribution mapping has enabled a new approach for operational measurements in proton exchange membrane fuel cells (PEMFC. Taking into account previously constructed measurement systems, a method based on a multi layer printed circuit board was chosen for the development of the new system. This type of system consists of a sensor, a special electronic device and the control and visualization PC. For the acquisition of the current density distribution values, a sensor device was designed and installed within a multilayer printed circuit board with integrated shunt resistors. Varying shunt values can be taken into consideration with a newly developed and evaluated calibration method. The sensor device was integrated in a PEM fuel cell stack to prove the functionality of the whole measurement system. A software application was implemented to visualize and save the measurement values. Its functionality was verified by operational measurements within a PEMFC system. Measurement accuracy and possible negative reactions of the sensor device during PEMFC operation are discussed in detail in this paper. The developed system enables operational measurements for different operating phases of PEM fuel cells. Additionally, this can be seen as a basis for new opportunities of optimization for fuel cell design and operation modes.

  5. Measurement of density and water content of soil using photon multiple scattering

    Science.gov (United States)

    Ertek, C.; Haselberger, N.

    1984-11-01

    A quantitative measure of density and of water content in soil was determined by photon multiple scattering following sample irradiation by a 0.7 mCi 137Cs source. Counting was effected using a stabilized single channel scintillation detector and counter system in the differential mode. Scattered photons of 80 keV energy were measured using a 20 keV window. The moving source method was applied to find the density of soil and count rate ratios of dry soil to wet soil. Independent calibrations were applied for the moisture measurements. Four curves were obtained for the soil density range of 0.5-1.5 g/cm 3 by using soil standards of 2.6, 7.0, 10.6 and 16.1 wt.% water content. Direct influence of photons was measured by blocking the direct path of photons to the detector by shielding both the Cs source and the detector.

  6. Density Measurement of Compact Toroid with Mach-Zehnder Interferometer

    Science.gov (United States)

    Laufman-Wollitzer, Lauren; Endrizzi, Doug; Brookhart, Matt; Flanagan, Ken; Forest, Cary

    2016-10-01

    Utilizing a magnetized coaxial plasma gun (MCPG) built by Tri Alpha Energy, a dense compact toroid (CT) is created and injected at high speed into the Wisconsin Plasma Astrophysics Laboratory (WiPAL) vessel. A modified Mach-Zehnder interferometer from the Line-Tied Reconnection Experiment (LTRX) provides an absolute measurement of electron density. The interferometer is located such that the beam intersects the plasma across the diameter of the MCPG drift region before the CT enters the vessel. This placement ensures that the measurement is taken before the CT expand. Results presented will be used to further analyze characteristics of the CT. Funding provided by DoE, NSF, and WISE Summer Research.

  7. Analytical representations of the spread harmonic measure density

    Science.gov (United States)

    Grebenkov, Denis S.

    2015-05-01

    We study the spread harmonic measure that characterizes the spatial distribution of reaction events on a partially reactive surface. For Euclidean domains in which Brownian motion can be split into independent lateral and transverse displacements, we derive analytical formulas for the spread harmonic measure density and analyze its asymptotic behavior. This analysis is applicable to slab domains, general cylindrical domains, and a half-space. We investigate the spreading effect due to multiple reflections on the surface, and the underlying role of finite reactivity. We discuss further extensions and applications of analytical results to describe Laplacian transfer phenomena such as permeation through semipermeable membranes, secondary current distribution on partially blocking electrodes, and surface relaxation in nuclear magnetic resonance.

  8. Selection and Evaluation of a new Pu Density Measurement Fluid

    Energy Technology Data Exchange (ETDEWEB)

    Dziewinska, Krystyna [Los Alamos National Laboratory; Peters, Michael A [Los Alamos National Laboratory; Martinez, Patrick P [Los Alamos National Laboratory; Dziewinski, Jacek J [Los Alamos National Laboratory; Pugmire, David L [Los Alamos National Laboratory; Trujillo, Stephen M [Los Alamos National Laboratory; La Verne, Jake A [UNIV OF NOTRE DAME; Rajesh, P [UNIV OF NOTRE DAME

    2009-01-01

    This paper summarizes efforts leading to selection of a new fluid for the determination of the density of large Pu parts. Based on an extended literature search, perfluorotributylamine (FC-43) was chosen for an experimental study. Plutonium coupon corrosion studies were performed by exposing Pu to deaerated and aerated solutions and measuring corrosion gravimetrically. Corrosion rates were determined. Samples of deaerated and aerated perfuluorotributylamine (FC-43) were also irradiated with {sup 60}Co gamma rays (96 Gy/min) to various doses. The samples were extracted with NaOH and analyzed by IC and showed the presence of F and Cl{sup -}. The G-values were established. In surface study experiments Pu coupons were exposed to deaerated and aerated solutions of FC-43 and analyzed by X-ray photoelectron spectroscopy (XPS). The XPS data indicate that there is no detectable surface effect caused by the new fluid. In conclusion the FC-43 was determined to be a very effective and practical fluid for Pu density measurements.

  9. Density Fluctuation Measurements by Far-Forward Collective Scattering in the HSX Stellarator

    Science.gov (United States)

    Deng, C.; Brower, D. L.; Anderson, D. T.; Anderson, F. S. B.; Likin, K.; Lore, J.; Schmitt, J. C.; Talmadge, J. N.; Wilcox, R.; Zhai, K.

    2010-11-01

    The multichannel interferometer system on the HSX stellarator is reconfigured to perform far-forward collective scattering measurements of electron density fluctuations. The collective scattering system has 9 viewing chords with 1.5 cm spacing. The source is a bias-tuned Gunn diode at 96 GHz with passive solid-state tripler providing output at 288 GHz (˜5 mW). The scattered power is measured using a homodyne detection scheme. Far-forward collective scattering provides a line-integrated measurement of fluctuations within the divergence of the probe beam covering wave number range: k< 2 cm-1. The perpendicular wave number consists of poloidal and radial contributions which vary with chord position. Comparison of density fluctuations measured using scattering and interferometry techniques will be made. Both coherent modes and broadband fluctuations are measured. Comparison of fluctuation amplitude and frequency spectra for quasi-helically symmetric and non-axisymmetric magnetic configuration will be presented.

  10. Measurement of Density Inhomogeneity for Source Masses in Time-of-Swing Method of Measuring G

    Institute of Scientific and Technical Information of China (English)

    LIU Lin-Xia; SHAO Cheng-Gang; TU Liang-Cheng; LUO Jun

    2009-01-01

    A method with scanning electron microscopy (SEM) is presented to measure the density inhomogeneity of the stainless steel (SS316) sphere prepared for measuring G using time-of-swing method. The experimental result shows that the relative density inhomogeneity of the sphere is better than 5.9 × 10-4 over the volume of 0.272 × 0.234 × 0.005 mm3. If we assume that the density inhomogeneity of the spheres used in our G measurement is the same as that of the sphere destroyed in testing, it will contribute to G value with an uncertainty of less than O.034 ppm in our G measurement. Furthermore, the mass centre offset from the geometric centre of the sphere will be less than 4.3 × 10-4 μm due to this inhomogeneity.

  11. MISCIBILITY, SOLUBILITY, VISCOSITY, AND DENSITY MEASUREMENTS FOR R-236FA WITH POTENTIAL LUBRICANTS

    Science.gov (United States)

    The report gives results of miscibility, solubility, viscosity, and density measurements for refrigerant R-236fa and two potential lubricants . (The data are needed to determine the suitability of refrigerant/lubricant combinations for use in refrigeration systems.) The tested oi...

  12. Measurement and correlation of density for related toluene diisocynate synthesis system%甲苯二异氰酸酯相关合成体系密度的测定与关联

    Institute of Scientific and Technical Information of China (English)

    宣爱国; 潘杨; 吴元欣; 胡冲; 李慧; 赵世平

    2013-01-01

    甲苯二异氰酸酯是重要的有机中间体,为了提供其相关合成反应的工业化设计所必需的密度、超额体积等关键物性数据,选定基础原料甲醇、乙醇、氨基甲酸甲酯为研究对象.分别用激光法测定了常压下甲醇+氨基甲酸甲酯和乙醇+氨基甲酸甲酯体系在293.15、308.15 K下固体溶质在液体中的溶解度,用间接测量法得到了相应条件下体系的混合密度,然后通过密度进一步计算得到了超额体积.对于上述体系,不同条件下各混合液的过量体积均为负;溶液组成一定时,超额体积随着温度的增加而减小;体系温度一定时,超额体积随着氨基甲酸甲酯摩尔分数的增加而减小.同时,对于不同温度下甲醇+氨基甲酸甲酯、乙醇+氨基甲酸甲酯体系密度与组成的关系,超额体积与组成的关系进行了线性关联,回归所得模型系数的最大标准偏差小于0.5%;用Redlich-Kister方程拟合了不同温度下的超额体积与组成的关系,回归所得模型参数的最大标准偏差小于5%.结果表明模型方程可适用于回归上述体系的物性数据.%Toluene diisocynate is an important organic intermediate. Methanol, ethanol and urethylane are key raw materials of toluene diisocynate synthesis. They are chosen to be the research object in order to provide the industry design of necessary physical data density and excess volume. Solubilities of the binary mixtures of methanol-urethylane and ethanol-urethylane at different compositions were determined at the temperature range from 293. 15 K to 308. 15 K and under atmospheric pressure by laser method, and mixture densities were measured by indirect method,then excess molar volumes were calculated by the density data. For the systems, excess molar volumes were negative; in addition, it decreased with the temperature rise as composition unchanged, and it decreased with the temperature rise as composition unchanged. Densities and

  13. Conceptual design of the tangentially viewing combined interferometer-polarimeter for ITER density measurements.

    Science.gov (United States)

    Van Zeeland, M A; Boivin, R L; Brower, D L; Carlstrom, T N; Chavez, J A; Ding, W X; Feder, R; Johnson, D; Lin, L; O'Neill, R C; Watts, C

    2013-04-01

    One of the systems planned for the measurement of electron density in ITER is a multi-channel tangentially viewing combined interferometer-polarimeter (TIP). This work discusses the current status of the design, including a preliminary optical table layout, calibration options, error sources, and performance projections based on a CO2/CO laser system. In the current design, two-color interferometry is carried out at 10.59 μm and 5.42 μm and a separate polarimetry measurement of the plasma induced Faraday effect, utilizing the rotating wave technique, is made at 10.59 μm. The inclusion of polarimetry provides an independent measure of the electron density and can also be used to correct the conventional two-color interferometer for fringe skips at all densities, up to and beyond the Greenwald limit. The system features five chords with independent first mirrors to reduce risks associated with deposition, erosion, etc., and a common first wall hole to minimize penetration sizes. Simulations of performance for a projected ITER baseline discharge show the diagnostic will function as well as, or better than, comparable existing systems for feedback density control. Calculations also show that finite temperature effects will be significant in ITER even for moderate temperature plasmas and can lead to a significant underestimate of electron density. A secondary role TIP will fulfill is that of a density fluctuation diagnostic; using a toroidal Alfvén eigenmode as an example, simulations show TIP will be extremely robust in this capacity and potentially able to resolve coherent mode fluctuations with perturbed densities as low as δn∕n ≈ 10(-5).

  14. Optimally focused cold atom systems obtained using density-density correlations.

    Science.gov (United States)

    Putra, Andika; Campbell, Daniel L; Price, Ryan M; De, Subhadeep; Spielman, I B

    2014-01-01

    Resonant absorption imaging is a common technique for detecting the two-dimensional column density of ultracold atom systems. In many cases, the system's thickness along the imaging direction greatly exceeds the imaging system's depth of field, making the identification of the optimally focused configuration difficult. Here we describe a systematic technique for bringing Bose-Einstein condensates (BEC) and other cold-atom systems into an optimal focus even when the ratio of the thickness to the depth of field is large: a factor of 8 in this demonstration with a BEC. This technique relies on defocus-induced artifacts in the Fourier-transformed density-density correlation function (the power spectral density, PSD). The spatial frequency at which these artifacts first appear in the PSD is maximized on focus; the focusing process therefore both identifies and maximizes the range of spatial frequencies over which the PSD is uncontaminated by finite-thickness effects.

  15. The decay of excited He from stochastic density-functional theory: a quantum measurement theory interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Bushong, Neil; Di Ventra, Massimiliano [Department of Physics, University of California, San Diego, La Jolla, CA 92093-0319 (United States)], E-mail: diventra@physics.ucsd.edu

    2008-10-01

    Recently, time-dependent current-density-functional theory has been extended to include the dynamical interaction of quantum systems with external environments (Di Ventra and D'Agosta 2007 Phys. Rev. Lett. 98 226403). Here we show that such a theory allows us to study a fundamentally important class of phenomena previously inaccessible by standard density-functional methods: the decay of excited systems. As an example we study the decay of an ensemble of excited He atoms, and discuss these results in the context of quantum measurement theory.

  16. Density measurements of potassium phosphate buffer from 4 to 45 degrees C.

    Science.gov (United States)

    Schiel, John E; Hage, David S

    2005-01-30

    Potassium phosphate buffer is often used in methods such as equilibrium dialysis, high performance liquid chromatography (HPLC), and affinity capillary electrophoresis (ACE) for characterizing the binding of drugs and hormones with proteins or other ligands within the body. In these experiments, the buffer density is often approximated to be that of water and the concentrations of all reagents are assumed to be constant with temperature. However, some difference in density between phosphate buffer and water would be expected, and variations in this density could lead to significant changes in the concentrations of dissolved solutes with temperature. This, in turn, could affect the binding observed for a solute-ligand system in such a buffer. In this study, the densities of potassium phosphate buffers with concentrations up to 0.10M were measured at or near physiological pH for temperatures ranging from 4-45 degrees C. The general change in density versus temperature followed a quadratic equation, while the changes in density with concentration and pH followed a linear response. The results were used to formulate a general equation that could be used to calculate the density of potassium phosphate buffer at any pH, temperature, and concentration within the tested range. This equation and more specialized relationships developed in the temperature, concentration, and pH studies were found to give much greater accuracy in describing the density of these buffers versus a previous relationship developed for solutions containing only potassium dihydrogen phosphate.

  17. Thermal microstructure measurement system

    Science.gov (United States)

    Carver, Michael J. (Inventor)

    1985-01-01

    A thermal microstructure measurement system (TMMS) operates autonomously h its own internal power supply and telemeters data to a platform. A thermal array is mounted on a cross-braced frame designed to orient itself normal to existing currents with fixed sensor positioning bars protruding from the cross bars. A plurality of matched thermistors, conductivity probes and inclinometers are mounted on the frame. A compass and pressure transducer are contained in an electronics package suspended below the array. The array is deployed on a taut mooring below a subsurface float. Data are digitized, transmitted via cable to a surface buoy and then telemetered to the platform where the data is processed via a computer, recorded and/or displayed. The platform computer also sends commands to the array via telemetry.

  18. Measurement of Bone Mineral Density in Male Detainees

    Directory of Open Access Journals (Sweden)

    Betül Bakan

    2012-12-01

    Full Text Available Aim: We aimed to investigate the increased risk for osteoporosis due to closed environment and sedentary lifestyle of prisoners. In this way, we planned to inform prisoners and supervisors for protective measures that should be taken if low bone mineral density (BMD is detected compared with normal population. Materials and Methods: Sixty six prisoner men over the age of 45 as the study group and 66 male volunteers who are not detainees over the age of 45 as a control group were included in the study. All participants' age, occupation, duration in prison, habits, nutrition, exercise, diseases and medications used were noted. BMD values were measured using a phalangeal radiographic absorptiometry (Alara Metriscan®. Results: BMD values in the study group were measured as 0.341±0.030 g/cm2 and as 0.346±0.029 g/cm2 in the control group (p=0.968. BMD values of the study group were lower than those of the control group. Conclusion: In this study, we found that BMD values of the detainees were lower than those of the control group but this difference was not statistically significant. However, there was a negative correlation between BMD values and duration in prison. (Turkish Journal of Osteoporosis 2012;18: 81-5

  19. Glacial density and GIA in Alaska estimated from ICESat, GPS and GRACE measurements

    Science.gov (United States)

    Jin, Shuanggen; Zhang, T. Y.; Zou, F.

    2017-01-01

    The density of glacial volume change in Alaska is a key factor in estimating the glacier mass loss from altimetry observations. However, the density of Alaskan glaciers has large uncertainty due to the lack of in situ measurements. In this paper, using the measurements of Ice, Cloud, and land Elevation Satellite (ICESat), Global Positioning System (GPS), and Gravity Recovery and Climate Experiment (GRACE) from 2003 to 2009, an optimal density of glacial volume change with 750 kg/m3 is estimated for the first time to fit the measurements. The glacier mass loss is -57.5 ± 6.5 Gt by converting the volumetric change from ICESat with the estimated density 750 kg/m3. Based on the empirical relation, the depth-density profiles are constructed, which show glacial density variation information with depths in Alaska. By separating the glacier mass loss from glacial isostatic adjustment (GIA) effects in GPS uplift rates and GRACE total water storage trends, the GIA uplift rates are estimated in Alaska. The best fitting model consists of a 60 km elastic lithosphere and 110 km thick asthenosphere with a viscosity of 2.0 × 1019 Pa s over a two-layer mantle.

  20. The gas density measurement of one long distance supersonic molecular beam

    Science.gov (United States)

    Liu, D.; Han, J. F.; Chen, Z. Y.; Bai, L. X.; Zhou, J. X.

    2016-12-01

    The gas density of the supersonic molecular beam (SMB) is a crucial parameter for the fueling or diagnostic process in the tokamak experiments. Using the microphone, one improved method of gas density measurement is proposed, which can greatly improve the measurement capacity by about 3 orders of magnitude by studying the pulsed signal characteristic of the microphone when it is pushed by the SMB. The gas density of the SMB is measured within the axial range of 20-2000 mm, and the axial central density at 2000 mm is about 100 times less than that at 20 mm. It is also found that the radial density distribution follows the Gaussian function in both free expansion (where the SMB can expand freely without any influence from the vacuum chamber) and restricted expansion (where the expansion of the SMB is restricted inside the flight tube of the vacuum system). And the axial central density decreases with the axial distance, which follows the inverse square law in the free expansion, but it deviates from this law in the restricted expansion.

  1. A Re-examination of Density Effects in Eddy Covariance Measurements of CO2 Fluxes

    Institute of Scientific and Technical Information of China (English)

    Heping LIU

    2009-01-01

    Corrections of density effects resulting from air-parcel expansion/compression are important in interpreting eddy covariance fluxes of water vapor and CO2 when open-path systems are used. To account for these effects, mean vertical velocity and perturbation of the density of dry air are two critical parameters in treating those physical processes responsible for density variations. Based on various underlying assumptions, different studies have obtained different formulas for the mean vertical velocity and perturbation of the density of dry air, leading to a number of approaches to correct density effects. In this study, we re-examine physical processes related to different assumptions that are made to formulate the density effects. Specifically, we re-examine the assumptions of a zero dry air flux and a zero moist air flux in the surface layer, used for treating density variations, and their implications for correcting density effects. It is found that physical processes in relation to the assumption of a zero dry air flux account for the influence of dry air expansion/compression on density variations. Meanwhile, physical processes in relation to the assumption of a zero moist air flux account for the influence of moist air expansion/compression on density variations. In this study, we also re-examine mixing ratio issues. Our results indicate that the assumption of a zero dry air flux favors the use of the mixing ratio relative to dry air, while the assumption of a zero moist air flux favors the use of the mixing ratio relative to the total moist air. Additionally, we compare different formula for the mean vertical velocity, generated by air-parcel expansion/compression, and for density effect corrections using eddy covariance data measured over three boreal ecosystems.

  2. Measurement of output power density from mobile phone as a function of input sound frequency.

    Science.gov (United States)

    Calabrò, Emanuele; Magazù, Salvatore

    2013-01-01

    Measurements of power density emitted by a mobile phone were carried out as a function of the sound frequency transmitted by a sound generator, ranging from 250 to 14000 Hz. Output power density was monitored by means of the selective radiation meter Narda SRM 3000 in spectrum analysis mode, and the octave frequency analysis of each tone used for the experimental design was acquired by the sound level meter Larson Davis LxT Wind. Vodafone providers were used for mobile phone calls with respect to various local base station in Southern-Italy. A relationship between the mobile phone microwaves power density and the sound frequencies transmitted by the sound generator was observed. In particular, microwaves power density level decreases significantly at sound frequency values larger than 4500 Hz. This result can be explained assuming that discontinuous transmission mode of global system for mobile communications is powered not only in silence-mode, but also at frequencies larger than 4500 Hz.

  3. X-ray beam hardening correction for measuring density in linear accelerator industrial computed tomography

    Institute of Scientific and Technical Information of China (English)

    ZHOU Ri-Feng; WANG Jue; CHEN Wei-Min

    2009-01-01

    Due to X-ray attenuation being approximately proportional to material density, it is possible to measure the inner density through Industrial Computed Tomography (ICT) images accurately. In practice, however, a number of factors including the non-linear effects of beam hardening and diffuse scattered radia-tion complicate the quantitative measurement of density variations in materials. This paper is based on the linearization method of beam hardening correction, and uses polynomial fitting coefficient which is obtained by the curvature of iron polychromatic beam data to fit other materials. Through theoretical deduction, the paper proves that the density measure error is less than 2% if using pre-filters to make the spectrum of linear accelerator range mainly 0.3 MeV to 3 MeV. Experiment had been set up at an ICT system with a 9 MeV electron linear accelerator. The result is satisfactory. This technique makes the beam hardening correction easy and simple, and it is valuable for measuring the ICT density and making use of the CT images to recognize materials.

  4. How to measure the charm density in the proton

    CERN Document Server

    Ivanov, N Ya

    2012-01-01

    We study two experimental ways to measure the heavy-quark content of the proton: using the Callan-Gross ratio $R(x,Q^2)=F_L/F_T$ and/or the azimuthal $\\cos(2\\varphi)$ asymmetry in DIS. Our approach is based on the following observations. First, the ratio $R(x,Q^2)=F_L/F_T$ and azimuthal $\\cos(2\\varphi)$ asymmetry in heavy-quark leptoproduction are stable, both parametrically and perturbatively, within pQCD. Second, both these quantities are sensitive to resummation of the mass logarithms of the type $\\alpha_{s}\\ln(Q^{2}/m^{2})$. We conclude that the heavy-quark densities in the nucleon can, in principle, be determined from high-$Q^2$ data on the Callan-Gross ratio and/or the azimuthal asymmetry. In particular, the charm content of the proton can be measured in future studies at the proposed Large Hadron-Electron (LHeC) and Electron-Ion (EIC) Colliders.

  5. Effect of Clothing on Measurement of Bone Mineral Density.

    Science.gov (United States)

    McNamara, Elizabeth A; Feldman, Anna Z; Malabanan, Alan O; Abate, Ejigayehu G; Whittaker, LaTarsha G; Yano-Litwin, Amanda; Dorazio, Jolene; Rosen, Harold N

    2016-01-01

    It is unknown whether allowing patients to have BMD (bone mineral density) studies acquired while wearing radiolucent clothing adlib contributes appreciably to the measurement error seen. To examine this question, a spine phantom was scanned 30 times without any clothing, while draped with a gown, and while draped with heavy winter clothing. The effect on mean BMD and on SD (standard deviation) was assessed. The effect of clothing on mean or SD of the area was not significant. The effect of clothing on mean and SD for BMD was small but significant and was around 1.6% for the mean. However, the effect on BMD precision was much more clinically important. Without clothing the spine phantom had an least significant change of 0.0077 gm/cm(2), while when introducing variability of clothing the least significant change rose as high as 0.0305 gm/cm(2). We conclude that, adding clothing to the spine phantom had a small but statistically significant effect on the mean BMD and on variance of the measurement. It is unlikely that the effect on mean BMD has any clinical significance, but the effect on the reproducibility (precision) of the result is likely clinically significant.

  6. Feasibility of measuring density and temperature of laser produced plasmas using spectroscopic techniques.

    Energy Technology Data Exchange (ETDEWEB)

    Edens, Aaron D.

    2008-09-01

    A wide variety of experiments on the Z-Beamlet laser involve the creation of laser produced plasmas. Having a direct measurement of the density and temperature of these plasma would an extremely useful tool, as understanding how these quantities evolve in space and time gives insight into the causes of changes in other physical processes, such as x-ray generation and opacity. We propose to investigate the possibility of diagnosing the density and temperature of laser-produced plasma using temporally and spatially resolved spectroscopic techniques that are similar to ones that have been successfully fielded on other systems. Various researchers have measured the density and temperature of laboratory plasmas by looking at the width and intensity ratio of various characteristic lines in gases such as nitrogen and hydrogen, as well as in plasmas produced off of solid targets such as zinc. The plasma conditions produce two major measurable effects on the characteristic spectral lines of that plasma. The 1st is the Stark broadening of an individual line, which depends on the electron density of the plasma, with higher densities leading to broader lines. The second effect is a change in the ratio of various lines in the plasma corresponding to different ionization states. By looking at the ratio of these lines, we can gain some understanding of the plasma ionization state and consequently its temperature (and ion density when coupled with the broadening measurement). The hotter a plasma is, the higher greater the intensity of lines corresponding to higher ionization states. We would like to investigate fielding a system on the Z-Beamlet laser chamber to spectroscopically study laser produced plasmas from different material targets.

  7. Measurement of average density and relative volumes in a dispersed two-phase fluid

    Science.gov (United States)

    Sreepada, Sastry R.; Rippel, Robert R.

    1992-01-01

    An apparatus and a method are disclosed for measuring the average density and relative volumes in an essentially transparent, dispersed two-phase fluid. A laser beam with a diameter no greater than 1% of the diameter of the bubbles, droplets, or particles of the dispersed phase is directed onto a diffraction grating. A single-order component of the diffracted beam is directed through the two-phase fluid and its refraction is measured. Preferably, the refracted beam exiting the fluid is incident upon a optical filter with linearly varing optical density and the intensity of the filtered beam is measured. The invention can be combined with other laser-based measurement systems, e.g., laser doppler anemometry.

  8. Two-Dimensional Electron Density Measurement of Positive Streamer Discharge in Atmospheric-Pressure Air

    Science.gov (United States)

    Inada, Yuki; Ono, Ryo; Kumada, Akiko; Hidaka, Kunihiko; Maeyama, Mitsuaki

    2016-09-01

    The electron density of streamer discharges propagating in atmospheric-pressure air is crucially important for systematic understanding of the production mechanisms of reactive species utilized in wide ranging applications such as medical treatment, plasma-assisted ignition and combustion, ozone production and environmental pollutant processing. However, electron density measurement during the propagation of the atmospheric-pressure streamers is extremely difficult by using the conventional localized type measurement systems due to the streamer initiation jitters and the irreproducibility in the discharge paths. In order to overcome the difficulties, single-shot two-dimensional electron density measurement was conducted by using a Shack-Hartmann type laser wavefront sensor. The Shack-Hartmann sensor with a temporal resolution of 2 ns was applied to pulsed positive streamer discharges generated in an air gap between pin-to-plate electrodes. The electron density a few ns after the streamer initiation was 7*1021m-3 and uniformly distributed along the streamer channel. The electron density and its distribution profile were compared with a previous study simulating similar streamers, demonstrating good agreement. This work was supported in part by JKA and its promotion funds from KEIRIN RACE. The authors like to thank Mr. Kazuaki Ogura and Mr. Kaiho Aono of The University of Tokyo for their support during this work.

  9. Electronic Structure Measurement of Solid Density Plasmas using X-Ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Gregori, G; Glenzer, S H; Rogers, F J; Landen, O L; Blancard, C; Faussurier, G; Renaudin, P; Kuhlbrodt, S; Redmer, R

    2003-08-23

    We present an improved analytical expression for the x-ray dynamic structure factor from a dense plasma which includes the effects of weakly bound electrons. This result can be applied to describe scattering from low to moderate Z plasmas, and it covers the entire range of plasma conditions that can be found in inertial confinement fusion experiments, from ideal to degenerate up to moderately coupled systems. We use our theory to interpret x-ray scattering experiments from solid density carbon plasma and to extract accurate measurements of electron temperature, electron density and charge state. We use our experimental results to validate various equation-of-state models for carbon plasmas.

  10. Measuring protoplanetary disk gas surface density profiles with ALMA

    CERN Document Server

    McPartland, Jonathan P Williams Conor

    2016-01-01

    The gas and dust are spatially segregated in protoplanetary disks due to the vertical settling and radial drift of large grains. A fuller accounting of the mass content and distribution in disks therefore requires spectral line observations. We extend the modeling approach presented in Williams & Best (2014) to show that gas surface density profiles can be measured from high fidelity 13CO integrated intensity images. We demonstrate the methodology by fitting ALMA observations of the HD 163296 disk to determine a gas mass, Mgas = 0.048 solar masse, and accretion disk characteristic size Rc = 213au and gradient gamma = 0.39. The same parameters match the C18O 2--1 image and indicates an abundance ratio [13CO]/[C18O] of 700 independent of radius. To test how well this methodology can be applied to future line surveys of smaller, lower mass T Tauri disks, we create a large 13CO 2--1 image library and fit simulated data. For disks with gas masses 3-10 Jupiter masses at 150pc, ALMA observations with a resolutio...

  11. Continuous Plasma density measurement in TJ-II infrared interferometer-Advanced signal processing based on FPGAs

    OpenAIRE

    2010-01-01

    This work presents the behavioral simulation in an FPGA of a novel processing system for measuring line average electronic density in the TJ-II stellarator diagnostic, Infra-Red Two-Color Interferometer. Line average electronic density is proportional to phase difference between probing and reference signals of the interferometer, as the Appleton–Hartree cold plasma model states. The novelty of the approach is the development of a real time measuring system where research work has been carrie...

  12. CO{sub 2} laser diagnostics for measurements of the plasma density profile and plasma density fluctuations on LHD

    Energy Technology Data Exchange (ETDEWEB)

    Vyacheslavov, L.N. [Budker Institute of Nuclear Physics, Novosibirsk (Russian Federation); Tanaka, K.; Kawahata, K. [National Inst. for Fusion Science, Toki, Gifu (Japan)

    2001-04-01

    A CO{sub 2} laser based diagnostics complimentary to the existing FIR interferometer is proposed. It combines interferometry for plasma density profile measurement under conditions of large density gradients, and both imaging and scattering techniques for observation of plasma fluctuations. Two-colour interferometer with a slablike probe beam and a single multichannel linear detector array provide observation of plasma density profile and density fluctuations at two locations along the probe beam. Basic characteristics of the diagnostics are considered as well as some effects that include dispersion and are critical for two colour imaging technique. The results of the bench-top experiments with the prototype of the interferometer are presented. (author)

  13. Density Measurements of Low Silica CaO-SiO2-Al2O3 Slags

    Science.gov (United States)

    Muhmood, Luckman; Seetharaman, Seshadri

    2010-08-01

    Density measurements of a low-silica CaO-SiO2-Al2O3 system were carried out using the Archimedes principle. A Pt 30 pct Rh bob and wire arrangement was used for this purpose. The results obtained were in good agreement with those obtained from the model developed in the current group as well as with other results reported earlier. The density for the CaO-SiO2 and the CaO-Al2O3 binary slag systems also was estimated from the ternary values. The extrapolation of density values for high-silica systems also showed good agreement with previous works. An estimation for the density value of CaO was made from the current experimental data. The density decrease at high temperatures was interpreted based on the silicate structure. As the mole percent of SiO2 was below the 33 pct required for the orthosilicate composition, discrete {text{SiO}}4^{4 - } tetrahedral units in the silicate melt would exist along with O2- ions. The change in melt expansivity may be attributed to the ionic expansions in the order of {text{Al}}^{ 3+ } - {text{O}}^{ 2- } < {text{Ca}}^{ 2+ } - {text{O}}^{ 2- } < {text{Ca}}^{ 2+ } - {text{O}}^{ - } Structural changes in the ternary slag also could be correlated to a drastic change in the value of enthalpy of mixing.

  14. The role of adequate reference materials in density measurements in hemodialysis

    Science.gov (United States)

    Furtado, A.; Moutinho, J.; Moura, S.; Oliveira, F.; Filipe, E.

    2015-02-01

    In hemodialysis, oscillation-type density meters are used to measure the density of the acid component of the dialysate solutions used in the treatment of kidney patients. An incorrect density determination of this solution used in hemodialysis treatments can cause several and adverse events to patients. Therefore, despite the Fresenius Medical Care (FME) tight control of the density meters calibration results, this study shows the benefits of mimic the matrix usually measured to produce suitable reference materials for the density meter calibrations.

  15. High-resolution gamma ray attenuation density measurements on mining exploration drill cores, including cut cores

    Science.gov (United States)

    Ross, P.-S.; Bourke, A.

    2017-01-01

    Physical property measurements are increasingly important in mining exploration. For density determinations on rocks, one method applicable on exploration drill cores relies on gamma ray attenuation. This non-destructive method is ideal because each measurement takes only 10 s, making it suitable for high-resolution logging. However calibration has been problematic. In this paper we present new empirical, site-specific correction equations for whole NQ and BQ cores. The corrections force back the gamma densities to the "true" values established by the immersion method. For the NQ core caliber, the density range extends to high values (massive pyrite, 5 g/cm3) and the correction is thought to be very robust. We also present additional empirical correction factors for cut cores which take into account the missing material. These "cut core correction factors", which are not site-specific, were established by making gamma density measurements on truncated aluminum cylinders of various residual thicknesses. Finally we show two examples of application for the Abitibi Greenstone Belt in Canada. The gamma ray attenuation measurement system is part of a multi-sensor core logger which also determines magnetic susceptibility, geochemistry and mineralogy on rock cores, and performs line-scan imaging.

  16. Shape transition of state density for bosonic systems

    Indian Academy of Sciences (India)

    Harshal N Deota; N D Chavda; V Potbhare

    2013-12-01

    For a finite boson system, the ensemble-averaged state density has been computed with respect to the body interaction rank . The shape of such a state density changes from Gaussian to semicircle as the body rank of the interaction increases. This state density is expressed as a linear superposition of Gaussian and semicircular states. The nearest-neighbour spacing distribution (NNSD), which is one of the most important spectral properties of a system, is studied. The NNSDs are rather independent of body rank and show a Wigner distribution throughout.

  17. Electron density profile measurements from hydrogen line intensity ratio method in Versatile Experiment Spherical Torus

    Science.gov (United States)

    Kim, YooSung; Shi, Yue-Jiang; Yang, Jeong-hun; Kim, SeongCheol; Kim, Young-Gi; Dang, Jeong-Jeung; Yang, Seongmoo; Jo, Jungmin; Oh, Soo-Ghee; Chung, Kyoung-Jae; Hwang, Y. S.

    2016-11-01

    Electron density profiles of versatile experiment spherical torus plasmas are measured by using a hydrogen line intensity ratio method. A fast-frame visible camera with appropriate bandpass filters is used to detect images of Balmer line intensities. The unique optical system makes it possible to take images of Hα and Hβ radiation simultaneously, with only one camera. The frame rate is 1000 fps and the spatial resolution of the system is about 0.5 cm. One-dimensional local emissivity profiles have been obtained from the toroidal line of sight with viewing dumps. An initial result for the electron density profile is presented and is in reasonable agreement with values measured by a triple Langmuir probe.

  18. Simultaneous streak and frame interferometry for electron density measurements of laser produced plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Quevedo, H. J., E-mail: hjquevedo@utexas.edu; McCormick, M.; Wisher, M.; Bengtson, Roger D.; Ditmire, T. [Center for High Energy Density Science, Department of Physics, University of Texas at Austin, Austin, Texas 78712 (United States)

    2016-01-15

    A system of two collinear probe beams with different wavelengths and pulse durations was used to capture simultaneously snapshot interferograms and streaked interferograms of laser produced plasmas. The snapshots measured the two dimensional, path-integrated, electron density on a charge-coupled device while the radial temporal evolution of a one dimensional plasma slice was recorded by a streak camera. This dual-probe combination allowed us to select plasmas that were uniform and axisymmetric along the laser direction suitable for retrieving the continuous evolution of the radial electron density of homogeneous plasmas. Demonstration of this double probe system was done by measuring rapidly evolving plasmas on time scales less than 1 ns produced by the interaction of femtosecond, high intensity, laser pulses with argon gas clusters. Experiments aimed at studying homogeneous plasmas from high intensity laser-gas or laser-cluster interaction could benefit from the use of this probing scheme.

  19. Simultaneous streak and frame interferometry for electron density measurements of laser produced plasmas

    Science.gov (United States)

    Quevedo, H. J.; McCormick, M.; Wisher, M.; Bengtson, Roger D.; Ditmire, T.

    2016-01-01

    A system of two collinear probe beams with different wavelengths and pulse durations was used to capture simultaneously snapshot interferograms and streaked interferograms of laser produced plasmas. The snapshots measured the two dimensional, path-integrated, electron density on a charge-coupled device while the radial temporal evolution of a one dimensional plasma slice was recorded by a streak camera. This dual-probe combination allowed us to select plasmas that were uniform and axisymmetric along the laser direction suitable for retrieving the continuous evolution of the radial electron density of homogeneous plasmas. Demonstration of this double probe system was done by measuring rapidly evolving plasmas on time scales less than 1 ns produced by the interaction of femtosecond, high intensity, laser pulses with argon gas clusters. Experiments aimed at studying homogeneous plasmas from high intensity laser-gas or laser-cluster interaction could benefit from the use of this probing scheme.

  20. Experiment to measure oxygen opacity at high density and temperature

    Science.gov (United States)

    Keiter, Paul; Mussack, Katie; Orban, Chris; Colgan, James; Ducret, Jean-Eric; Fontes, Christopher J.; Guzik, Joyce Ann; Heeter, Robert F.; Kilcrease, Dave; Le Pennec, Maelle; Mancini, Roberto; Perry, Ted; Turck-Chièze, Sylvaine; Trantham, Matt

    2017-06-01

    In recent years, there has been a debate over the abundances of heavy elements (Z >2) in the solar interior. Recent solar atmosphere models [Asplund 2009] find a significantly lower abundance for C, N, and O compared to models used roughly a decade ago. This discrepancy has led to an investigation of opacities through laboratory experiments and improved opacity models for many of the larger contributors to the sun’s opacity, including iron and oxygen. Recent opacity measurements of iron disagree with opacity model predictions [Bailey et al, 2015]. Although these results are still controversial, repeated scrutiny of the experiment and data has not produced a conclusive reason for the discrepancy. New models have been implemented in the ATOMIC opacity code for C, O and Fe to address the solar abundance issue [Colgan, 2013]. Armstrong et al [2014] have also implemented changes in the ATOMIC code for low-Z elements. However, no data currently exists to test the low-Z material models in the regime relevant to the solar convection zone. We present an experimental design using the opacity platform developed at the National Ignition Facility to study the oxygen opacity at densities and temperatures near the solar convection zone conditions.This work is funded by the U.S. DOE, through the NNSA-DS and SC-OFES Joint Program in HEDPLP, grant No. DE-NA0001840, and the NLUF Program, grant No. DE-NA0000850, and through LLE, University of Rochester by the NNSA/OICF under Agreement No. DE-FC52-08NA28302.

  1. Measuring the Magnetic Flux Density in the CMS Steel Yoke

    CERN Document Server

    Klyukhin, V I; Ball, A; Curé, B; Gaddi, A; Gerwig, H; Hervé, A; Mulders, M; Loveless, R

    2012-01-01

    The Compact Muon Solenoid (CMS) is a general purpose detector, designed to run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its distinctive features include a 4 T superconducting solenoid with 6-m-diameter by 12.5-m-length free bore, enclosed inside a 10000-ton return yoke made of construction steel. The return yoke consists of five dodecagonal three-layered barrel wheels and four end-cap disks at each end comprised of steel blocks up to 620 mm thick, which serve as the absorber plates of the muon detection system. Accurate characterization of the magnetic field everywhere in the CMS detector is required. To measure the field in and around the steel, a system of 22 flux-loops and 82 3-D Hall sensors is installed on the return yoke blocks. Fast discharges of the solenoid (190 s time-constant) made during the CMS magnet surface commissioning test at the solenoid central fields of 2.64, 3.16, 3.68 and 4.01 T were used to induce voltages in the flux-loops. The voltages are measured on-line a...

  2. Bone mineral density in juvenile systemic lupus erythematosus

    Directory of Open Access Journals (Sweden)

    Castro T.C.M.

    2002-01-01

    Full Text Available We evaluated spine bone mineral density (BMD in Brazilian children with juvenile systemic lupus erythematosus (JSLE in order to detect potential predictors of reduction in bone mass. A cross-sectional study of BMD at the lumbar spine level (L2-L4 was conducted on 16 female JSLE patients aged 6-17 years. Thirty-two age-matched healthy girls were used as control. BMD at the lumbar spine was measured by dual-energy X-ray absorptiometry. Weight, height and pubertal Tanner stage were determined in patients and controls. Disease duration, mean daily steroid doses, mean cumulative steroid doses and JSLE activity measured by the systemic lupus erythematosus disease activity index (SLEDAI were determined for all JSLE patients based on their medical charts. All parameters were used as potential determinant factors for bone loss. Lumbar BMD tended to be lower in the JSLE patients, however, this difference was not statistically significant (P = 0.10. No significant correlation was observed in JSLE girls between BMD and age, height, Tanner stage, disease duration, corticosteroid use or disease activity. We found a weak correlation between BMD and weight (r = 0.672. In the JSLE group we found no significant parameters to correlate with reduced bone mass. Disease activity and mean cumulative steroid doses were not related to BMD values. We did not observe reduced bone mass in female JSLE.

  3. Measurements of plasma density fluctuations and electric wave fields using spherical electrostatic probes

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, A.I.; Bostroem, R.

    1995-04-01

    Spherical electrostatic probes are in wide use for the measurements of electric fields and plasma density. This report concentrates on the measurements of fluctuations of these quantities rather than background values. Potential problems with the technique include the influence of density fluctuations on electric field measurements and vice versa, effects of varying satellite potential, and non-linear rectification in the probe and satellite sheaths. To study the actual importance of these and other possible effects, we simulate the response of the probe-satellite system to various wave phenomena in the plasma by applying approximate analytical as well as numerical methods. We use a set of non-linear probe equations, based on probe characteristics experimentally obtained in space, and therefore essentially independent of any specific probe theory. This approach is very useful since the probe theory for magnetized plasmas is incomplete. 47 refs.

  4. A fibre based triature interferometer for measuring rapidly evolving, ablatively driven plasma densities

    Science.gov (United States)

    Macdonald, J.; Bland, S. N.; Threadgold, J.

    2015-08-01

    We report on the first use of a fibre interferometer incorporating triature analysis for measuring rapidly evolving plasma densities of ne ˜ 1013/cm3 and above, such as those produced by simple coaxial plasma guns. The resultant system is extremely portable, easy to field in experiments, relatively cheap to produce, and—with the exception of a small open area in which the plasma is sampled—safe in operation as all laser light is enclosed.

  5. A new and facile method for measurement of apparent density of monodisperse polymer beads.

    Science.gov (United States)

    Zhang, Qi; Srinivasan, Balasubramanian; Li, Yuanpeng; Jing, Ying; Xing, Chengguo; Chang, Jin; Wang, Jian-Ping

    2010-03-15

    The apparent density, an intrinsic physical property of polymer beads, plays an important role in the application of beads in micro-total analysis systems and separation. Here we have developed a new, facile and milligram-scale method to describe the motion of beads in aqueous solution and further detect the apparent density of beads. The motion of beads in solutions is determined by the viscosity of solutions and the density difference between beads and solutions. In this study, using various glycerol aqueous solutions with certain viscosities and densities, the motion time (i.e. floating or sedimentation time) of hybrid polymer beads was experimentally measured and theoretically deduced, and consequently, the apparent density of monodisperse beads can be quickly and easily calculated. The results indicated that the present method provided a more precise way to predict the movement of hybrid beads in aqueous solution compared with the approach for commercial use. This new method can be potentially employed in flow cytometry, suspension stability, and particle analysis systems.

  6. Smart-Phone Based Magnetic Levitation for Measuring Densities.

    Science.gov (United States)

    Knowlton, Stephanie; Yu, Chu Hsiang; Jain, Nupur; Ghiran, Ionita Calin; Tasoglu, Savas

    2015-01-01

    Magnetic levitation, which uses a magnetic field to suspend objects in a fluid, is a powerful and versatile technology. We develop a compact magnetic levitation platform compatible with a smart-phone to separate micro-objects and estimate the density of the sample based on its levitation height. A 3D printed attachment is mechanically installed over the existing camera unit of a smart-phone. Micro-objects, which may be either spherical or irregular in shape, are suspended in a paramagnetic medium and loaded in a microcapillary tube which is then inserted between two permanent magnets. The micro-objects are levitated and confined in the microcapillary at an equilibrium height dependent on their volumetric mass densities (causing a buoyancy force toward the edge of the microcapillary) and magnetic susceptibilities (causing a magnetic force toward the center of the microcapillary) relative to the suspending medium. The smart-phone camera captures magnified images of the levitating micro-objects through an additional lens positioned between the sample and the camera lens cover. A custom-developed Android application then analyzes these images to determine the levitation height and estimate the density. Using this platform, we were able to separate microspheres with varying densities and calibrate their levitation heights to known densities to develop a technique for precise and accurate density estimation. We have also characterized the magnetic field, the optical imaging capabilities, and the thermal state over time of this platform.

  7. Smart-Phone Based Magnetic Levitation for Measuring Densities.

    Directory of Open Access Journals (Sweden)

    Stephanie Knowlton

    Full Text Available Magnetic levitation, which uses a magnetic field to suspend objects in a fluid, is a powerful and versatile technology. We develop a compact magnetic levitation platform compatible with a smart-phone to separate micro-objects and estimate the density of the sample based on its levitation height. A 3D printed attachment is mechanically installed over the existing camera unit of a smart-phone. Micro-objects, which may be either spherical or irregular in shape, are suspended in a paramagnetic medium and loaded in a microcapillary tube which is then inserted between two permanent magnets. The micro-objects are levitated and confined in the microcapillary at an equilibrium height dependent on their volumetric mass densities (causing a buoyancy force toward the edge of the microcapillary and magnetic susceptibilities (causing a magnetic force toward the center of the microcapillary relative to the suspending medium. The smart-phone camera captures magnified images of the levitating micro-objects through an additional lens positioned between the sample and the camera lens cover. A custom-developed Android application then analyzes these images to determine the levitation height and estimate the density. Using this platform, we were able to separate microspheres with varying densities and calibrate their levitation heights to known densities to develop a technique for precise and accurate density estimation. We have also characterized the magnetic field, the optical imaging capabilities, and the thermal state over time of this platform.

  8. Human photoreceptor cone density measured with adaptive optics technology (rtx1 device) in healthy eyes: Standardization of measurements.

    Science.gov (United States)

    Zaleska-Żmijewska, Anna; Wawrzyniak, Zbigniew M; Ulińska, Magdalena; Szaflik, Jerzy; Dąbrowska, Anna; Szaflik, Jacek P

    2017-06-01

    The anatomic structures of the anterior segment of the eye enable correct reception of stimuli by the retina, which contains receptors that receive light impulses and transmit them to the visual cortex. The aim of this study was to assess the effect of the size of the sampling window in an adaptive optics (AO) flood-illumination retinal camera (rtx1) on cone density measurements in the eyes of healthy individuals and to investigate the differences in cone density and spacing in different quadrants of the retina. Thirty-three subjects with no ophthalmic or systemic disease underwent a detailed ophthalmologic examination. Photographs of retinal fragments 3 degrees from the fovea were taken using the rtx1 AO retinal camera. We used sampling windows with 3 sizes (50 × 50, 100 × 100, and 250 × 250 μm). Cone density, spacing, and shape were determined using AOdetect software. The median (interquartile range) cone density was 19,269 (4964) cones/mm. There were statistically significant differences between measurements taken with the 50/50 and 250/250-m windows. There were no significant differences in the cone spacing results between any of the windows examined, but the measurements differed according to location between the superior and temporal quadrants. The most common cone shape was hexagonal (47.6%) for all window sizes and locations. These findings may help in the development of a normative database for variation in cone density in healthy subjects and to allow the best window to be chosen for obtain the most correct values for eccentricity measurements of 3 degrees. In our study, the optimal sampling window was 100 × 100 μm.

  9. Systems Measures of Water Distribution System Resilience

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Katherine A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Murray, Regan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Walker, La Tonya Nicole [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Resilience is a concept that is being used increasingly to refer to the capacity of infrastructure systems to be prepared for and able to respond effectively and rapidly to hazardous events. In Section 2 of this report, drinking water hazards, resilience literature, and available resilience tools are presented. Broader definitions, attributes and methods for measuring resilience are presented in Section 3. In Section 4, quantitative systems performance measures for water distribution systems are presented. Finally, in Section 5, the performance measures and their relevance to measuring the resilience of water systems to hazards is discussed along with needed improvements to water distribution system modeling tools.

  10. Laser ultrasonics for bulk-density distribution measurement on green ceramic tiles

    Science.gov (United States)

    Revel, G. M.; Cavuto, A.; Pandarese, G.

    2016-10-01

    In this paper a Laser Ultrasonics (LUT) system is developed and applied to measure bulk density distribution of green ceramic tiles, which are porous materials with low heat conductivity. Bulk density of green ceramic bodies is a fundamental parameter to be kept under control in the industrial production of ceramic tiles. The LUT system proposed is based on a Nd:YAG pulsed laser for excitation and an air-coupled electro-capacitive transducer for detection. The paper reports experimental apparent bulk-density measurements on white ceramic bodies after a calibration procedures. The performances observed are better than those previously achieved by authors using air-coupled ultrasonic probes for both emission and detection, allowing to reduce average uncertainty down to about ±6 kg/m3 (±0.3%), thanks to the increase in excitation efficiency and lateral resolution, while maintaining potential flexibility for on-line application. The laser ultrasonic procedure proposed is available for both on-line and off-line application. In this last case it is possible to obtain bulk density maps with high spatial resolution by a 2D scan without interrupting the production process.

  11. Bulk density estimation using a 3-dimensional image acquisition and analysis system

    Directory of Open Access Journals (Sweden)

    Heyduk Adam

    2016-01-01

    Full Text Available The paper presents a concept of dynamic bulk density estimation of a particulate matter stream using a 3-d image analysis system and a conveyor belt scale. A method of image acquisition should be adjusted to the type of scale. The paper presents some laboratory results of static bulk density measurements using the MS Kinect time-of-flight camera and OpenCV/Matlab software. Measurements were made for several different size classes.

  12. Measurement System and Calibration report

    DEFF Research Database (Denmark)

    Kock, Carsten Weber; Vesth, Allan

    This Measurement System & Calibration report is describing DTU’s measurement system installed at a specific wind turbine. A major part of the sensors has been installed by others (see [1]) the rest of the sensors have been installed by DTU. The results of the measurements, described in this report...

  13. Measurement System and Calibration report

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Villanueva, Héctor

    This Measurement System & Calibration report is describing DTU’s measurement system installed at a specific wind turbine. A major part of the sensors has been installed by others (see [1]) the rest of the sensors have been installed by DTU. The results of the measurements, described in this repor...

  14. Measuring surface state density and energy distribution in InAs nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Halpern, Eliezer; Cohen, Gilad; Gross, Shahar; Henning, Alexander; Matok, Max; Rosenwaks, Yossi [Department of Physical Electronics, School of Electrical Engineering, Tel-Aviv University (Israel); Kretinin, Andrey V. [School of Physics and Astronomy, University of Manchester (United Kingdom); Shtrikman, Hadas [Department of Condensed Matter Physics, Braun Center for Submicrometer Research, Weizmann Institute of Science, Rehovot (Israel)

    2014-02-15

    Semiconducting nanowires are expected to have applications in various areas as transistors, sensors, resonators, solar cells, and thermoelectric systems. Understanding the surface properties is crucial for the fabrication of high-performance devices. Due to the large surface-to-volume ratio of nanowires, their surface electronic properties, like surface states, can a have a large effect on the performance of both electronic and optoelectronic devices. At present, determination of the surface state density depends on a combination of experimental measurements of the capacitance and/or drain current, in a nanowire field-effect transistor, and a fitting to simulation. This technique follows certain assumptions, which can severely harm the accuracy of the extracted density of states. In this report, we demonstrate a direct measurement of the surface state density of individual InAs and silicon nanowires. The method is based on measuring the surface potential of a nanowire field-effect transistor, with respect to a changing gate bias. The extracted density of states at the surface helps to explain various electronic phenomena in such devices. (copyright 2014 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. Measurement Systems Advisory Group

    Science.gov (United States)

    1974-04-01

    noted with the aluminum wire used in the lacing. For these reasons the tests were concluded and deemed unsatisfactory. The second system tested was an...vehicle for "bringing many particulate pollutants into contact with the tape or magnetic heads, e.g., from deodorant spray powders, face powder and

  16. Measuring name system health

    NARCIS (Netherlands)

    Casalicchio, Emiliano; Caselli, M.; Coletta, Alessio; Di Blasi, Salvatore; Fovino, Igor Nai; Butts, Jonathan; Shenoi, Sujeet

    2012-01-01

    Modern critical infrastructure assets are exposed to security threats arising from their use of IP networks and the Domain Name System (DNS). This paper focuses on the health of DNS. Indeed, due to the increased reliance on the Internet, the degradation of DNS could have significant consequences for

  17. Measuring name system health

    NARCIS (Netherlands)

    Casalicchio, Emiliano; Caselli, Marco; Coletta, Alessio; Di Blasi, Salvatore; Fovino, Igor Nai; Butts, Jonathan; Shenoi, Sujeet

    2012-01-01

    Modern critical infrastructure assets are exposed to security threats arising from their use of IP networks and the Domain Name System (DNS). This paper focuses on the health of DNS. Indeed, due to the increased reliance on the Internet, the degradation of DNS could have significant consequences for

  18. The redshift number density evolution of Mg Ⅱ absorption systems

    Institute of Scientific and Technical Information of China (English)

    Zhi-Fu Chen

    2013-01-01

    We make use of the recent large sample of 17 042 Mg Ⅱ absorption systems from Quider et al.to analyze the evolution of the redshift number density.Regardless of the strength of the absorption line,we find that the evolution of the redshift number density can be clearly distinguished into three different phases.In the intermediate redshift epoch (0.6 ≤ z ≤ 1.6),the evolution of the redshift number density is consistent with the non-evolution curve,however,the non-evolution curve over-predicts the values of the redshift number density in the early (z ≤ 0.6) and late (z ≥ 1.6) epochs.Based on the invariant cross-section of the absorber,the lack of evolution in the redshift number density compared to the non-evolution curve implies the galaxy number density does not evolve during the middle epoch.The fiat evolution of the redshift number density tends to correspond to a shallow evolution in the galaxy merger rate during the late epoch,and the steep decrease of the redshift number density might be ascribed to the small mass of halos during the early epoch.

  19. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    NARCIS (Netherlands)

    Santos, E.M.; Yoo, A.J.; Beenen, L.F.; Berkhemer, O.A.; Blanken, M.D. den; Wismans, C.; Niessen, W.J.; Majoie, C.B.; Marquering, H.A.; Dijk, E.J. van

    2016-01-01

    INTRODUCTION: Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and

  20. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    NARCIS (Netherlands)

    E.M.M. Santos (Emilie M.); A.J. Yoo (Albert J.); L.F.M. Beenen (Ludo); O.A. Berkhemer (Olvert); M.D. Den Blanken (Mark D.); C. Wismans (Carrie); W.J. Niessen (Wiro); C.B. Majoie (Charles); H. Marquering (Henk)

    2016-01-01

    textabstractIntroduction: Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by

  1. Density-based similarity measures for content based search

    Energy Technology Data Exchange (ETDEWEB)

    Hush, Don R [Los Alamos National Laboratory; Porter, Reid B [Los Alamos National Laboratory; Ruggiero, Christy E [Los Alamos National Laboratory

    2009-01-01

    We consider the query by multiple example problem where the goal is to identify database samples whose content is similar to a coUection of query samples. To assess the similarity we use a relative content density which quantifies the relative concentration of the query distribution to the database distribution. If the database distribution is a mixture of the query distribution and a background distribution then it can be shown that database samples whose relative content density is greater than a particular threshold {rho} are more likely to have been generated by the query distribution than the background distribution. We describe an algorithm for predicting samples with relative content density greater than {rho} that is computationally efficient and possesses strong performance guarantees. We also show empirical results for applications in computer network monitoring and image segmentation.

  2. The benchmark of gutzwiller density functional theory in hydrogen systems

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Y.; Wang, Cai-Zhuang; Ho, Kai-Ming

    2012-02-23

    We propose an approximate form of the exchange-correlation energy functional for the Gutzwiller density functional theory. It satisfies certain physical constraints in both weak and strong electron correlation limits. We benchmark the Gutzwiller density functional approximation in the hydrogen systems, where the static correlation error is shown to be negligible. The good transferability is demonstrated by applications to the hydrogen molecule and some crystal structures.

  3. The Benchmark of Gutzwiller Density Functional Theory in Hydrogen Systems

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Yongxin; Wang, Cai-Zhuang; Ho, Kai-Ming

    2011-01-13

    We propose an approximate form of the exchange-correlation energy functional for the Gutzwiller density functional theory. It satisfies certain physical constraints in both weak and strong electron correlation limits. We benchmark the Gutzwiller density functional approximation in the hydrogen systems, where the static correlation error is shown to be negligible. The good transferability is demonstrated by applications to the hydrogen molecule and some crystal structures. © 2011 Wiley Periodicals, Inc. Int J Quantum Chem, 2012

  4. Stationary density matrix of a pumped polariton system.

    Science.gov (United States)

    Vera, Carlos Andrés; Cabo, Alejandro; González, Augusto

    2009-03-27

    The density matrix rho of a model polariton system is obtained numerically from a master equation which takes account of pumping and losses. In the stationary limit, the coherences between eigenstates of the Hamiltonian are 3 orders of magnitude smaller than the occupations, meaning that the stationary density matrix is approximately diagonal in the energy representation. A weakly distorted grand canonical Gibbs distribution fits well the occupations.

  5. Eddy Correlation Flux Measurement System

    Data.gov (United States)

    Oak Ridge National Laboratory — The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat,...

  6. Multiple Traffic Control Using Wireless Sensor and Density Measuring Camera

    Directory of Open Access Journals (Sweden)

    Amrita RAI

    2008-07-01

    Full Text Available In the present scenario vehicular travel is increasing all over the world, especially in large urban areas. Therefore for simulating and optimizing traffic control to better accommodate this increasing demand is arises. In this paper we studied the optimization of traffic light controller in a City using wireless sensor and CCTV (Camera. We have proposed a traffic light controller and simulator that allows us to study different situation of traffic density in City and controlling the traffic of entire City by visual monitoring using CCTV. Using wireless sensor we can easily senses the density of traffic because the general architecture of wireless sensor network is an infrastructure less communication network.

  7. Eddy Correlation Flux Measurement System Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Cook, D. R. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-01-01

    The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO2) (and methane at one Southern Great Plains extended facility (SGP EF) and the North Slope of Alaska Central Facility (NSA CF). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO2 concentration. The instruments used are: • a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature) • an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO2 concentration, and • an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at one SGP EF and at the NSA CF. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A Surface Energy Balance System (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), ARM Mobile Facility 1 (AMF1), and ARM Mobile Facility 2 (AMF2). The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. The SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes. The SEBS at one SGP and one NSA site also support upwelling and downwelling PAR measurements to qualify those two locations as Ameriflux sites.

  8. Density and Viscosity Measurement of Diesel Fuels at Combined High Pressure and Elevated Temperature

    Directory of Open Access Journals (Sweden)

    Carl Schaschke

    2013-07-01

    Full Text Available We report the measurement of the viscosity and density of various diesel fuels, obtained from British refineries, at elevated pressures up to 500 MPa and temperatures in the range 298 K to 373 K. The measurement and prediction procedures of fluid properties under high pressure conditions is of increasing interest in many processes and systems including enhanced oil recovery, automotive engine fuel injection, braking, and hydraulic systems. Accurate data and understanding of the fluid characteristic in terms of pressure, volume and temperature is required particularly where the fluid is composed of a complex mixture or blend of aliphatic or aromatic hydrocarbons. In this study, high pressure viscosity data was obtained using a thermostatically-controlled falling sinker-type high pressure viscometer to provide reproducible and reliable viscosity data based on terminal velocity sinker fall times. This was supported with density measurements using a micro-pVT device. Both high-pressure devices were additionally capable of illustrating the freezing points of the hydrocarbon mixtures. This work has, thus, provided data that can extend the application of mixtures of commercially available fuels and to test the validity of available predictive density and viscosity models. This included a Tait-style equation for fluid compressibility prediction. For complex diesel fuel compositions, which have many unidentified components, the approach illustrates the need to apply appropriate correlations, which require accurate knowledge or prediction of thermodynamic properties.

  9. High Energy Density Regenerative Fuel Cell Systems for Terrestrial Applications

    Science.gov (United States)

    Burke, Kenneth A.

    1999-01-01

    Regenerative Fuel Cell System (RFCS) technology for energy storage has been a NASA power system concept for many years. Compared to battery-based energy storage systems, RFCS has received relatively little attention or resources for development because the energy density and electrical efficiency were not sufficiently attractive relative to advanced battery systems. Even today, RFCS remains at a very low technology readiness level (TRL of about 2 indicating feasibility has been demonstrated). Commercial development of the Proton Exchange Membrane (PEM) fuel cells for automobiles and other terrestrial applications and improvements in lightweight pressure vessel design to reduce weight and improve performance make possible a high energy density RFCS energy storage system. The results from this study of a lightweight RFCS energy storage system for a remotely piloted, solar-powered, high altitude aircraft indicate an energy density up to 790 w-h/kg with electrical efficiency of 53.4% is attainable. Such an energy storage system would allow a solar-powered aircraft to carry hundreds of kilograms of payload and remain in flight indefinitely for use in atmospheric research, earth observation, resource mapping. and telecommunications. Future developments in the areas of hydrogen and oxygen storage, pressure vessel design, higher temperature and higher- pressure fuel cell operation, unitized regenerative fuel cells, and commercial development of fuel cell technology will improve both the energy density and electrical efficiency of the RFCS.

  10. Schlieren technique applied to the arc temperature measurement in a high energy density cutting torch

    Science.gov (United States)

    Prevosto, L.; Artana, G.; Mancinelli, B.; Kelly, H.

    2010-01-01

    Plasma temperature and radial density profiles of the plasma species in a high energy density cutting arc have been obtained by using a quantitative schlieren technique. A Z-type two-mirror schlieren system was used in this research. Due to its great sensibility such technique allows measuring plasma composition and temperature from the arc axis to the surrounding medium by processing the gray-level contrast values of digital schlieren images recorded at the observation plane for a given position of a transverse knife located at the exit focal plane of the system. The technique has provided a good visualization of the plasma flow emerging from the nozzle and its interactions with the surrounding medium and the anode. The obtained temperature values are in good agreement with those values previously obtained by the authors on the same torch using Langmuir probes.

  11. Waveform measurement of charge- and spin-density wavepackets in a chiral Tomonaga-Luttinger liquid

    Science.gov (United States)

    Hashisaka, M.; Hiyama, N.; Akiho, T.; Muraki, K.; Fujisawa, T.

    2017-06-01

    In contrast to a free-electron system, a Tomonaga-Luttinger (TL) liquid in a one-dimensional (1D) electron system hosts charge and spin excitations as independent entities. When an electron is injected into a TL liquid, it transforms into charge- and spin-density wavepackets that propagate at different group velocities and move away from each other. This process, known as spin-charge separation, is the hallmark of TL physics. While spin-charge separation has been probed in momentum- or frequency-domain measurements in various 1D systems, waveforms of separated excitations, which are a direct manifestation of the TL behaviour, have been long awaited to be measured. Here, we present a waveform measurement for the pseudospin-charge separation process in a chiral TL liquid comprising quantum Hall edge channels. The charge- and pseudospin-density waveforms are captured by utilizing a spin-resolved sampling scope that records the spin-up or -down component of the excitations. This experimental technique provides full information for time evolution of the 1D electron system, including not only propagation of TL eigenmodes but also their decay in a practical device.

  12. A Method to Improve Electron Density Measurement of Cone-Beam CT Using Dual Energy Technique

    Directory of Open Access Journals (Sweden)

    Kuo Men

    2015-01-01

    Full Text Available Purpose. To develop a dual energy imaging method to improve the accuracy of electron density measurement with a cone-beam CT (CBCT device. Materials and Methods. The imaging system is the XVI CBCT system on Elekta Synergy linac. Projection data were acquired with the high and low energy X-ray, respectively, to set up a basis material decomposition model. Virtual phantom simulation and phantoms experiments were carried out for quantitative evaluation of the method. Phantoms were also scanned twice with the high and low energy X-ray, respectively. The data were decomposed into projections of the two basis material coefficients according to the model set up earlier. The two sets of decomposed projections were used to reconstruct CBCT images of the basis material coefficients. Then, the images of electron densities were calculated with these CBCT images. Results. The difference between the calculated and theoretical values was within 2% and the correlation coefficient of them was about 1.0. The dual energy imaging method obtained more accurate electron density values and reduced the beam hardening artifacts obviously. Conclusion. A novel dual energy CBCT imaging method to calculate the electron densities was developed. It can acquire more accurate values and provide a platform potentially for dose calculation.

  13. Density measurement of confined water with neutron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yang [ORNL; Faraone, Antonio [National Institute of Standards and Technology (NIST); Kamitakahara, William [ORNL; Liu, Kao-Hsiang [National Taiwan University; Mou, Chung-Yuan [National Taiwan University; Leao, Juscelino B [ORNL; Chang, Sung C [ORNL; Chen, Sow-hsin H [ORNL

    2011-01-01

    This is a response to Soper's two comments (1) regarding our papers (2, 3) in PNAS that (a) the distribution of water across the pores is not uniform and (b) the majority of water may reside outside the pores. Here, we show that we have given proper consideration to both issues and have reconfirmed the validity of our method and conclusion as elaborated in the following. The possibility that layering effects across the pores may introduce errors in associating the (100) interchannel peak height with density is not a new idea (reference 3 in ref. 1), and it has already been addressed (2). The arguments of Sopor (4) mainly rest on the assumption that the average density of water does not depend on temperature.

  14. MEASUREMENT OF ROOT LENGTH DENSITY IN INTACT SAMPLES USING X-RADIOGRAPHY AND IMAGE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Alain Pierret

    2011-05-01

    Full Text Available Measurement of root system attributes is of critical importance to understand and model plant growth. Root length density, the length of roots per unit volume of soil, is one of the important parameters required to understand plant performance. Measuring techniques currently in use to assess this parameter, such as for example core washing, are notoriously imprecise and labour-intensive. Roots and soil being inextricably linked, it is virtually impossible to separate them without loosing a significant amount of the root sample to be measured. This noticeably compromises the accuracy of washing techniques. For this reason, non-invasive measurement approaches are highly desirable. Here, a method based on the combination of X-radiography and image analysis is proposed as a new alternative for the measurement of root length density from intact samples. The successive steps of the method, from sampling to image acquisition are briefly described. A specific measurement algorithm, designed to account for the complex spatial arrangement of the roots within the samples is then presented and discussed in detail.

  15. Quantum measurement-induced antiferromagnetic order and density modulations in ultracold Fermi gases in optical lattices

    Science.gov (United States)

    Mazzucchi, Gabriel; Caballero-Benitez, Santiago F.; Mekhov, Igor B.

    2016-08-01

    Ultracold atomic systems offer a unique tool for understanding behavior of matter in the quantum degenerate regime, promising studies of a vast range of phenomena covering many disciplines from condensed matter to quantum information and particle physics. Coupling these systems to quantized light fields opens further possibilities of observing delicate effects typical of quantum optics in the context of strongly correlated systems. Measurement backaction is one of the most funda- mental manifestations of quantum mechanics and it is at the core of many famous quantum optics experiments. Here we show that quantum backaction of weak measurement can be used for tailoring long-range correlations of ultracold fermions, realizing quantum states with spatial modulations of the density and magnetization, thus overcoming usual requirement for a strong interatomic interactions. We propose detection schemes for implementing antiferromagnetic states and density waves. We demonstrate that such long-range correlations cannot be realized with local addressing, and they are a consequence of the competition between global but spatially structured backaction of weak quantum measurement and unitary dynamics of fermions.

  16. Quantum measurement-induced antiferromagnetic order and density modulations in ultracold Fermi gases in optical lattices.

    Science.gov (United States)

    Mazzucchi, Gabriel; Caballero-Benitez, Santiago F; Mekhov, Igor B

    2016-08-11

    Ultracold atomic systems offer a unique tool for understanding behavior of matter in the quantum degenerate regime, promising studies of a vast range of phenomena covering many disciplines from condensed matter to quantum information and particle physics. Coupling these systems to quantized light fields opens further possibilities of observing delicate effects typical of quantum optics in the context of strongly correlated systems. Measurement backaction is one of the most funda- mental manifestations of quantum mechanics and it is at the core of many famous quantum optics experiments. Here we show that quantum backaction of weak measurement can be used for tailoring long-range correlations of ultracold fermions, realizing quantum states with spatial modulations of the density and magnetization, thus overcoming usual requirement for a strong interatomic interactions. We propose detection schemes for implementing antiferromagnetic states and density waves. We demonstrate that such long-range correlations cannot be realized with local addressing, and they are a consequence of the competition between global but spatially structured backaction of weak quantum measurement and unitary dynamics of fermions.

  17. An affordable and accurate conductivity probe for density measurements in stratified flows

    Science.gov (United States)

    Carminati, Marco; Luzzatto-Fegiz, Paolo

    2015-11-01

    In stratified flow experiments, conductivity (combined with temperature) is often used to measure density. The probes typically used can provide very fine spatial scales, but can be fragile, expensive to replace, and sensitive to environmental noise. A complementary instrument, comprising a low-cost conductivity probe, would prove valuable in a wide range of applications where resolving extremely small spatial scales is not needed. We propose using micro-USB cables as the actual conductivity sensors. By removing the metallic shield from a micro-B connector, 5 gold-plated microelectrodes are exposed and available for 4-wire measurements. These have a cell constant ~550m-1, an intrinsic thermal noise of at most 30pA/Hz1/2, as well as sub-millisecond time response, making them highly suitable for many stratified flow measurements. In addition, we present the design of a custom electronic board (Arduino-based and Matlab-controlled) for simultaneous acquisition from 4 sensors, with resolution (in conductivity, and resulting density) exceeding the performance of typical existing probes. We illustrate the use of our conductivity-measuring system through stratified flow experiments, and describe plans to release simple instructions to construct our complete system for around 200.

  18. Multi Point Velocity, Density and Temperature Measurements using LITA Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Laser induced thermal acoustics (LITA) is a nonintrusive, transient-grating optical technique that provides simultaneous high-accuracy measurements of velocity,...

  19. Evaluation of Modified Pycnometric Method for Accurately Measuring the Density of Molten Nickel

    Institute of Scientific and Technical Information of China (English)

    XIAO Feng; FANG Liang; FU Yuechao; YANG Lingchuan

    2004-01-01

    A modified pycnometric method has been developed to obtain accurate densities of molten nickel.The new method allows continuous measurement of density over a wide temperature range from a single experiment.The measurement error of the method was analyzed, and the total uncertainty of the measurement was estimated to be within ±0.34%. The measured density of molten nickel decreases linearly with increasing temperature over a range from the melting point to 1873K. The density at the melting point and the thermal expansion coefficient of molten nickel are 7.90Mg·m-3 and 1.92×10-4 K-1,respectively.

  20. Density-Driven segregation in Binary and Ternary Granular Systems

    NARCIS (Netherlands)

    Windows-Yule, Kit; Parker, David

    2015-01-01

    We present a first experimental study of density-induced segregation within a three-dimensional, vibrofluidised, ternary granular system. Using Positron Emission Particle Tracking (PEPT), we study the steady-state particle distributions achieved by binary and ternary granular beds under a variety of

  1. Density-Driven segregation in Binary and Ternary Granular Systems

    NARCIS (Netherlands)

    Windows-Yule, Kit; Parker, David

    2015-01-01

    We present a first experimental study of density-induced segregation within a three-dimensional, vibrofluidised, ternary granular system. Using Positron Emission Particle Tracking (PEPT), we study the steady-state particle distributions achieved by binary and ternary granular beds under a variety of

  2. Asymptotic Analysis of Invariant Density of Randomly Perturbed Dynamical Systems

    OpenAIRE

    Mikami, Toshio

    1990-01-01

    The invariant density of diffusion processes which are small random perturbations of dynamical systems can be expanded in W.K.B. type, as the random effect disappears, in the set in which the Freidlin-Wentzell quasipotential $V(\\cdot)$ is of $C^\\infty$-class and each coefficient which appears in the expansion is of $C^\\infty$-class.

  3. Semiclassical theory for spatial density oscillations in fermionic systems.

    Science.gov (United States)

    Roccia, J; Brack, M; Koch, A

    2010-01-01

    We investigate the particle and kinetic-energy densities for a system of N fermions bound in a local (mean-field) potential V(r) . We generalize a recently developed semiclassical theory [J. Roccia and M. Brack, Phys. Rev. Lett. 100, 200408 (2008)] in which the densities are calculated in terms of the closed orbits of the corresponding classical system to D>1 dimensions. We regularize the semiclassical results (i) for the U(1) symmetry breaking occurring for spherical systems at r=0 and (ii) near the classical turning points where the Friedel oscillations are predominant and well reproduced by the shortest orbit going from r to the closest turning point and back. For systems with spherical symmetry, we show that there exist two types of oscillations which can be attributed to radial and nonradial orbits, respectively. The semiclassical theory is tested against exact quantum-mechanical calculations for a variety of model potentials. We find a very good overall numerical agreement between semiclassical and exact numerical densities even for moderate particle numbers N . Using a "local virial theorem," shown to be valid (except for a small region around the classical turning points) for arbitrary local potentials, we can prove that the Thomas-Fermi functional tau(TF)[rho] reproduces the oscillations in the quantum-mechanical densities to first order in the oscillating parts.

  4. Fundamental-measure density functional for the fluid of aligned hard hexagons: Further insights in fundamental measure theory.

    Science.gov (United States)

    Capitán, José A; Cuesta, José A

    2007-07-01

    In this article we obtain a fundamental measure functional for the model of aligned hard hexagons in the plane. Our aim is not just to provide a functional for an admittedly academic model, but to investigate the structure of fundamental measure theory. A model of aligned hard hexagons has similarities with the hard disk model. Both share "lost cases," i.e. admit configurations of three particles in which there is pairwise overlap but not triple overlap. These configurations are known to be problematic for fundamental measure functionals, which are not able to capture their contribution correctly. This failure lies in the inability of these functionals to yield a correct low density limit of the third order direct correlation function. Here we derive the functional by projecting aligned hard cubes on the plane x+y+z=0 . The correct dimensional crossover behavior of these functionals permits us to follow this strategy. The functional of aligned hard cubes, however, does not have lost cases, so neither had the resulting functional for aligned hard hexagons. The latter exhibits, in fact, a peculiar structure as compared to the one for hard disks. It depends on a uniparametric family of weighted densities through an additional term not appearing in the functional for hard disks. Apart from studying the freezing of this system, we discuss the implications of the functional structure for further developments of fundamental measure theory.

  5. Accuracy of cutoff probe for measuring electron density: simulation and experiment

    Science.gov (United States)

    Kim, Dae-Woong; You, Shin-Jae; Kim, Si-June; Lee, Jang-Jae; Kim, Jung-Hyung; Oh, Wang-Yuhl

    2016-09-01

    The electron density has been used for characterizing the plasma for basic research as well as industrial application. To measure the exact electron density, various type of microwave probe has been developed and improved. The cutoff probe is a promising technique inferring the electron density from the plasma resonance peak on the transmission spectrum. In this study, we present the accuracy of electron density inferred from cutoff probe. The accuracy was investigated by electromagnetic simulation and experiment. The discrepancy between the electron densities from the cutoff probe and other sophisticated microwave probes were investigated and discussed. We found that the cutoff probe has good accuracy in inferred electron density. corresponding author.

  6. Two new methods to detect cosmic voids without density measurements

    CERN Document Server

    Elyiv, Andrii; Pollina, Giorgia; Baldi, Marco; Branchini, Enzo; Cimatti, Andrea; Moscardini, Lauro

    2014-01-01

    Cosmic voids are effective cosmological probes to discriminate among competing world models. Their precise and unbiased identification is a prerequisite to perform accurate observational tests. The identification is generally based on density or geometry criteria that, because of their very nature, are prone to shot noise errors. In this work we propose two new void finders that are based on dynamical and clustering criteria to select voids in the Lagrangian coordinates and minimise the impact of sparse sampling. The first approach exploits the Zeldovich approximation to trace back in time the orbits of galaxies located in the voids and their surroundings, whereas the second uses the observed galaxy-galaxy correlation function to relax the objects' spatial distribution to homogeneity and isotropy. In both cases voids are defined as regions of the negative velocity divergence in Lagrangian coordinates, that can be regarded as sinks of the back-in-time streamlines of the mass tracers. To assess the performance ...

  7. Density of states of Frenkel excitons in weakly disordered systems

    Science.gov (United States)

    Boukahil, Abdelkrim; Zettili, Nouredine

    2002-04-01

    We present the calculation of the density of states of Frenkel excitons in weakly disordered one , two , and three-dimensional systems. A random distribution of transition frequencies with variance s2 characterizes the disorder. The Coherent Potential Approximation (CPA) calculations show that the density of states (DOS) is very sensitive to any variations in the disorder parameter s. Our calculations are in good agreement with previous work based on the Monte Carlo simulation. One of us (AB) acknowldges the support of the University of Wisconsin--Whitewater for this work through a university research grant.

  8. Reconstruction of conductivity and current density images using only one component of magnetic field measurements.

    Science.gov (United States)

    Seo, Jin Keun; Yoon, Jeong-Rock; Woo, Eung Je; Kwon, Ohin

    2003-09-01

    Magnetic resonance current density imaging (MRCDI) is to provide current density images of a subject using a magnetic resonance imaging (MRI) scanner with a current injection apparatus. The injection current generates a magnetic field that we can measure from MR phase images. We obtain internal current density images from the measured magnetic flux densities via Ampere's law. However, we must rotate the subject to acquire all of the three components of the induced magnetic flux density. This subject rotation is impractical in clinical MRI scanners when the subject is a human body. In this paper, we propose a way to eliminate the requirement of subject rotation by careful mathematical analysis of the MRCDI problem. In our new MRCDI technique, we need to measure only one component of the induced magnetic flux density and reconstruct both cross-sectional conductivity and current density images without any subject rotation.

  9. Eddy Correlation Flux Measurement System (ECOR) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Cook, DR

    2011-01-31

    The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO2) (and methane at one Southern Great Plains extended facility (SGP EF) and the North Slope of Alaska Central Facility (NSA CF). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO2 concentration.

  10. Online measurement of mass density and viscosity of pL fluid samples with suspended microchannel resonator

    DEFF Research Database (Denmark)

    Khan, Faheem; Schmid, Silvan; Larsen, Peter Emil

    2013-01-01

    Physical characterization of viscous samples is crucial in chemical, pharma and petroleum industry. For example, in the refining industry of petroleum, water percentage is verified by measuring the density of a sample. In this article we present a suspended microchannel resonator (SMR) which uses 5...... pL of a fluid sample and measures its density with a resolution of 0.01 kg/m 3 and a sensitivity of 16 Hz/kg/m3. The resonator can also simultaneously measure viscosity of the solutions with an accuracy of 0.025 mPa s. The SMR is part of a system which contains packaging and tubing to deliver...... samples to the resonator. The system can easily handle multiple viscous fluids to measure their densities and viscosities. The SMR is transparent, facilitating visual inspection of the microchannel content. © 2013 Elsevier B.V....

  11. The Construction of Plasma Density Feedback Control System on J-TEXT Tokamak

    Science.gov (United States)

    Ke, Xin; Chen, Zhipeng; Ba, Weigang; Shu, Shuangbao; Gao, Li; Zhang, Ming; Zhuang, Ge

    2016-02-01

    The plasma density feedback control system (PDFCS) has been established on the Joint Texas Experimental Tokamak (J-TEXT) for meeting the need for an accurate plasma density in physical experiments. It consists of a density measurement subsystem, a feedback control subsystem and a gas puffing subsystem. According to the characteristic of the gas puffing system, a voltage amplitude control mode has been applied in the feedback control strategy, which is accomplished by the proportion, integral and differential (PID) controller. In this system, the quantity calibration of gas injection, adjusted responding to the change of the density signal, has been carried out. Some experimental results are shown and discussed. supported by the National Magnetic Confinement Fusion Science Program (Nos. 2014GB103001 and 2013GB106001) and National Natural Science Foundation of China (Nos. 11305070 and 11105028)

  12. Electronically swept millimeter-wave interferometer for spatially resolved measurement of plasma electron density.

    Science.gov (United States)

    Howard, John; Oliver, David

    2006-12-01

    We report the development and initial implementation of what we believe to be a new rapid- spatial-scan millimeter-wave interferometer for plasma density measurements. The fast scan is effected by electronic frequency sweeping of a wideband (180-280 GHz) backward-wave oscillator whose output is focused onto a fixed blazed diffraction grating. The system, which augments the rotating-grating scanned multiview H-1 heliac interferometer, can sweep the plasma cross section in a period of less than 1 ms with a beam diameter in the plasma of 20 mm and phase noise of the order of 0.01 rad.

  13. Carbon Dioxide Flux Measurement Systems

    Data.gov (United States)

    Oak Ridge National Laboratory — The Southern Great Plains (SGP) carbon dioxide flux (CO2 flux) measurement systems provide half-hour average fluxes of CO2, H2O (latent heat), and sensible heat. The...

  14. Calculation of correction factors for ionization chamber measurements with small fields in low-density media.

    Science.gov (United States)

    Pisaturo, O; Pachoud, M; Bochud, F O; Moeckli, R

    2012-07-21

    The quantity of interest for high-energy photon beam therapy recommended by most dosimetric protocols is the absorbed dose to water. Thus, ionization chambers are calibrated in absorbed dose to water, which is the same quantity as what is calculated by most treatment planning systems (TPS). However, when measurements are performed in a low-density medium, the presence of the ionization chamber generates a perturbation at the level of the secondary particle range. Therefore, the measured quantity is close to the absorbed dose to a volume of water equivalent to the chamber volume. This quantity is not equivalent to the dose calculated by a TPS, which is the absorbed dose to an infinitesimally small volume of water. This phenomenon can lead to an overestimation of the absorbed dose measured with an ionization chamber of up to 40% in extreme cases. In this paper, we propose a method to calculate correction factors based on the Monte Carlo simulations. These correction factors are obtained by the ratio of the absorbed dose to water in a low-density medium □D(w,Q,V1)(low) averaged over a scoring volume V₁ for a geometry where V₁ is filled with the low-density medium and the absorbed dose to water □D(w,QV2)(low) averaged over a volume V₂ for a geometry where V₂ is filled with water. In the Monte Carlo simulations, □D(w,QV2)(low) is obtained by replacing the volume of the ionization chamber by an equivalent volume of water, according to the definition of the absorbed dose to water. The method is validated in two different configurations which allowed us to study the behavior of this correction factor as a function of depth in phantom, photon beam energy, phantom density and field size.

  15. A high speed compact microwave interferometer for density fluctuation measurements in Sino-UNIted Spherical Tokamak

    Science.gov (United States)

    Zhong, H.; Tan, Y.; Liu, Y. Q.; Xie, H. Q.; Gao, Z.

    2016-11-01

    A single-channel 3 mm interferometer has been developed for plasma density diagnostics in the Sino-UNIted Spherical Tokamak (SUNIST). The extremely compact microwave interferometer utilizes one corrugated feed horn antenna for both emitting and receiving the microwave. The beam path lies on the equatorial plane so the system would not suffer from beam path deflection problems due to the symmetry of the cross section. A focusing lens group and an oblique vacuum window are carefully designed to boost the signal to noise ratio, which allows this system to show good performance even with the small-diameter central column itself as a reflector, without a concave mirror. The whole system discards the reference leg for maximum compactness, which is particularly suitable for the small-sized tokamak. An auto-correcting algorithm is developed to calculate the phase evolution, and the result displays good phase stability of the whole system. The intermediate frequency is adjustable and can reach its full potential of 2 MHz for best temporal resolution. Multiple measurements during ohmic discharges proved the interferometer's capability to track typical density fluctuations in SUNIST, which enables this system to be utilized in the study of MHD activities.

  16. Endovascular blood flow measurement system

    Science.gov (United States)

    Khe, A. K.; Cherevko, A. A.; Chupakhin, A. P.; Krivoshapkin, A. L.; Orlov, K. Yu

    2016-06-01

    In this paper an endovascular measurement system used for intraoperative cerebral blood flow monitoring is described. The system is based on a Volcano ComboMap Pressure and Flow System extended with analogue-to-digital converter and PC laptop. A series of measurements performed in patients with cerebrovascular pathologies allows us to introduce “velocity-pressure” and “flow rate-energy flow rate” diagrams as important characteristics of the blood flow. The measurement system presented here can be used as an additional instrument in neurosurgery for assessment and monitoring of the operation procedure. Clinical data obtained with the system are used for construction of mathematical models and patient-specific simulations. The monitoring of the blood flow parameters during endovascular interventions was approved by the Ethics Committee at the Meshalkin Novosibirsk Research Institute of Circulation Pathology and included in certain surgical protocols for pre-, intra- and postoperative examinations.

  17. Wavefront-sensor-based electron density measurements for laser-plasma accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Plateau, Guillaume; Matlis, Nicholas; Geddes, Cameron; Gonsalves, Anthony; Shiraishi, Satomi; Lin, Chen; van Mourik, Reinier; Leemans, Wim

    2010-02-20

    Characterization of the electron density in laser produced plasmas is presented using direct wavefront analysis of a probe laser beam. The performance of a laser-driven plasma-wakefield accelerator depends on the plasma wavelength, hence on the electron density. Density measurements using a conventional folded-wave interferometer and using a commercial wavefront sensor are compared for different regimes of the laser-plasma accelerator. It is shown that direct wavefront measurements agree with interferometric measurements and, because of the robustness of the compact commercial device, have greater phase sensitivity, straightforward analysis, improving shot-to-shot plasma-density diagnostics.

  18. Modeling dendrite density from magnetic resonance diffusion measurements

    DEFF Research Database (Denmark)

    Jespersen, Sune Nørhøj; Kroenke, CD; Østergaard, Leif;

    2007-01-01

    Diffusion-weighted imaging (DWI) provides a noninvasive tool to probe tissue microstructure. We propose a simplified model of neural cytoarchitecture intended to capture the essential features important for water diffusion as measured by NMR. Two components contribute to the NMR signal in this mo...

  19. Bioimpedance for the spot measurement of tissue density

    Science.gov (United States)

    Dylke, E. S.; Ward, L. C.; Stannard, C.; Leigh, A.; Kilbreath, S. L.

    2013-04-01

    Long-standing lymphoedema is characterised by tissues changes which are currently not detectable using bioimpedance spectroscopy. It has been suggested that a combination of bipolar and tetrapolar measurements may be used to detect these tissues changes for a single site in the transverse direction. This was technique was trialled in a group of control participants with no history of lymphoedema or recent upper limb trauma. Repeated spot measurements were done without removal of electrodes to determine biological variability as well as with removal of electrodes to determine technical reproducibility. The inter-limb spot ratio of the controls was then compared to that of a number of women previously diagnosed with secondary lymphoedema in the forearm. Biological variability was not found to greatly influence repeated measures but only moderate technical reliability was found despite excellent co-efficient of variation for the majority of the measurements. A difference was seen between those with more severe swelling and the controls. This novel technique shows promise in detecting tissue changes associated with long-standing lymphoedema.

  20. Fundamental measure density functional theory study of hard spheres solid-liquid interface

    Science.gov (United States)

    Warshavsky, Vadim

    2005-03-01

    Interfacial free energy is an important characteristic of solid-liquid interface as it is one of the crucial parameters in many formula of interface thermodynamics such the nucleation theory. Previously different aspects of crystal-melt interfaces were intensively studied with simulations [1,2,3], but theoretical studies with Density Functional Theories (DFT) are inconclusive [4,5]. In this report the structure of hard spheres fcc crystal-melt interfaces and the anisotropy of the interfacial free energies are studied using the Rosenfeld's Fundamental Measure DFT as such a functional leads to reliable coexistence results not only for the hard sphere system but also for the Lennard-Jones systems [6]. The parameters of interfacial density profile were calculated by a proper minimization procedure. For the equilibrium density profile the interfacial free energies were compared with simulation results. 1. R.L.Davidchak and B.B.Laird, Phys.Rev.Lett., 85, 4751(2000). 2. J.J. Hoyt, M. Asta and A. Karma, Phys.Rev.Lett., 86, 5530 (2001). 3. J.R.Morris and X.Song, J.Chem.Phys., 119, 3920 (2003). 4. W.A.Curtin, Phys.Rev.B, 39, 6775(1989). 5. R.Ohnesorge, H.Lowen, and H.Wagner, Phys.Rev.E, 50, 4801 (1994). 6. V.Warshavsky and X.Song, Phys.Rev.E, 69, 061113 (2004).

  1. Drag balance Cubesat attitude motion effects on in-situ thermosphere density measurements

    Science.gov (United States)

    Felicetti, Leonard; Santoni, Fabio

    2014-08-01

    The dynamics of Cubesats carrying a drag balance instrument (DBI) for in situ atmosphere density measurements is analyzed. Atmospheric drag force is measured by the displacement of two light plates exposed to the incoming particle flow. This system is well suited for a distributed sensor network in orbit, to get simultaneous in situ local (non orbit averaged) measurements in multiple positions and orbit heights, contributing to the development and validation of global atmosphere models. The implementation of the DBI leads to orbit normal pointing spinning two body system. The use of a spin-magnetic attitude control system is suggested, based only on magnetometer readings, contributing to making the system simple, inexpensive, and reliable. It is shown, by an averaging technique, that this system provides for orbit normal spin axis pointing. The effect of the coupling between the attitude dynamics and the DBI is evaluated, analyzing its frequency content and showing that no frequency components arise, affecting the DBI performance. The analysis is confirmed by Monte Carlo numerical simulation results.

  2. Plasma Density Measurements on Refuelling by Solid Hydrogen Pellets in a Rotating Plasma

    DEFF Research Database (Denmark)

    Jørgensen, L. W.; Sillesen, A. H.

    1978-01-01

    The authors used laser interferometry to directly measure the increase in plasma density caused by the ablation of a solid hydrogen pellet situated in a rotating plasma.......The authors used laser interferometry to directly measure the increase in plasma density caused by the ablation of a solid hydrogen pellet situated in a rotating plasma....

  3. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Emilie M.M. [Erasmus MC - University Medical Center Rotterdam, Department of Radiology, P.O. Box 2040, Rotterdam (Netherlands); Department of Radiology, AMC, Amsterdam (Netherlands); Yoo, Albert J. [Texas Stroke Institute, Plano, TX (United States); Beenen, Ludo F.; Majoie, Charles B. [Department of Radiology, AMC, Amsterdam (Netherlands); Berkhemer, Olvert A. [Department of Radiology, AMC, Amsterdam (Netherlands); Department of Neurology, Erasmus MC, Rotterdam (Netherlands); Blanken, Mark D. den; Wismans, Carrie [AMC, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Niessen, Wiro J. [Erasmus MC - University Medical Center Rotterdam, Department of Radiology, P.O. Box 2040, Rotterdam (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Delft (Netherlands); Marquering, Henk A. [Department of Radiology, AMC, Amsterdam (Netherlands); AMC, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Collaboration: on behalf of the MR CLEAN investigators

    2016-02-15

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert observers. For 132 consecutive patients with acute ischemic stroke, three experts and two trained observers determined thrombus density by placing three standardized regions of interest (ROIs) in the thrombus and corresponding contralateral arterial segment. Subsequently, absolute and relative thrombus densities were determined using either one or three ROIs. Intraclass correlation coefficient (ICC) was determined, and Bland-Altman analysis was performed to evaluate interobserver and intermethod agreement. Accuracy of the trained observer was evaluated with a reference expert observer using the same statistical analysis. The highest interobserver agreement was obtained for absolute thrombus measurements using three ROIs (ICCs ranging from 0.54 to 0.91). In general, interobserver agreement was lower for relative measurements, and for using one instead of three ROIs. Interobserver agreement of trained non-experts and experts was similar. Accuracy of the trained observer measurements was comparable to the expert interobserver agreement and was better for absolute measurements and with three ROIs. The agreement between the one ROI and three ROI methods was good. Absolute thrombus density measurement has superior interobserver agreement compared to relative density measurement. Interobserver variation is smaller when multiple ROIs are used. Trained non-expert observers can accurately and reproducibly assess absolute thrombus densities using three ROIs. (orig.)

  4. Time-dependent density-functional theory for extended systems

    Energy Technology Data Exchange (ETDEWEB)

    Botti, Silvana [European Theoretical Spectroscopy Facility (ETSF) (Country Unknown); Schindlmayr, Arno [European Theoretical Spectroscopy Facility (ETSF) (Country Unknown); Del Sole, Rodolfo [European Theoretical Spectroscopy Facility (ETSF) (Country Unknown); Reining, Lucia [European Theoretical Spectroscopy Facility (ETSF) (Country Unknown)

    2007-03-15

    For the calculation of neutral excitations, time-dependent density functional theory (TDDFT) is an exact reformulation of the many-body time-dependent Schroedinger equation, based on knowledge of the density instead of the many-body wavefunction. The density can be determined in an efficient scheme by solving one-particle non-interacting Schroedinger equations-the Kohn-Sham equations. The complication of the problem is hidden in the-unknown-time-dependent exchange and correlation potential that appears in the Kohn-Sham equations and for which it is essential to find good approximations. Many approximations have been suggested and tested for finite systems, where even the very simple adiabatic local-density approximation (ALDA) has often proved to be successful. In the case of solids, ALDA fails to reproduce optical absorption spectra, which are instead well described by solving the Bethe-Salpeter equation of many-body perturbation theory (MBPT). On the other hand, ALDA can lead to excellent results for loss functions (at vanishing and finite momentum transfer). In view of this and thanks to recent successful developments of improved linear-response kernels derived from MBPT, TDDFT is today considered a promising alternative to MBPT for the calculation of electronic spectra, even for solids. After reviewing the fundamentals of TDDFT within linear response, we discuss different approaches and a variety of applications to extended systems.

  5. Open-system Kohn-Sham density functional theory.

    Science.gov (United States)

    Zhou, Yongxi; Ernzerhof, Matthias

    2012-03-07

    A simple model for electron transport through molecules is provided by the source-sink potential (SSP) method [F. Goyer, M. Ernzerhof, and M. Zhuang, J. Chem. Phys. 126, 144104 (2007)]. In SSP, the boundary conditions of having an incoming and outgoing electron current are enforced through complex potentials that are added to the Hamiltonian. Depending on the sign of the imaginary part of the potentials, current density is generated or absorbed. In this way, a finite system can be used to model infinite molecular electronic devices. The SSP has originally been developed for the Hückel method and subsequently it has been extended [F. Goyer and M. Ernzerhof, J. Chem. Phys. 134, 174101 (2011)] to the Hubbard model. Here we present a step towards its generalization for first-principles electronic structure theory methods. In particular, drawing on our earlier work, we discuss a new generalized density functional theory for complex non-Hermitian Hamiltonians. This theory enables us to combine SSP and Kohn-Sham theory to obtain a method for the description of open systems that exchange current density with their environment. Similarly, the Hartree-Fock method is extended to the realm of non-Hermitian, SSP containing Hamiltonians. As a proof of principle, we present the first applications of complex-density functional theory (CODFT) as well as non-Hermitian Hartree-Fock theory to electron transport through molecules. © 2012 American Institute of Physics

  6. Random density matrices versus random evolution of open system

    Science.gov (United States)

    Pineda, Carlos; Seligman, Thomas H.

    2015-10-01

    We present and compare two families of ensembles of random density matrices. The first, static ensemble, is obtained foliating an unbiased ensemble of density matrices. As criterion we use fixed purity as the simplest example of a useful convex function. The second, dynamic ensemble, is inspired in random matrix models for decoherence where one evolves a separable pure state with a random Hamiltonian until a given value of purity in the central system is achieved. Several families of Hamiltonians, adequate for different physical situations, are studied. We focus on a two qubit central system, and obtain exact expressions for the static case. The ensemble displays a peak around Werner-like states, modulated by nodes on the degeneracies of the density matrices. For moderate and strong interactions good agreement between the static and the dynamic ensembles is found. Even in a model where one qubit does not interact with the environment excellent agreement is found, but only if there is maximal entanglement with the interacting one. The discussion is started recalling similar considerations for scattering theory. At the end, we comment on the reach of the results for other convex functions of the density matrix, and exemplify the situation with the von Neumann entropy.

  7. Measuring Complexity of SAP Systems

    Directory of Open Access Journals (Sweden)

    Ilja Holub

    2016-10-01

    Full Text Available The paper discusses the reasons of complexity rise in ERP system SAP R/3. It proposes a method for measuring complexity of SAP. Based on this method, the computer program in ABAP for measuring complexity of particular SAP implementation is proposed as a tool for keeping ERP complexity under control. The main principle of the measurement method is counting the number of items or relations in the system. The proposed computer program is based on counting of records in organization tables in SAP.

  8. Experimental study of stratified jet by simultaneous measurements of velocity and density fields

    Science.gov (United States)

    Xu, Duo; Chen, Jun

    2012-07-01

    Stratified flows with small density difference commonly exist in geophysical and engineering applications, which often involve interaction of turbulence and buoyancy effect. A combined particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF) system is developed to measure the velocity and density fields in a dense jet discharged horizontally into a tank filled with light fluid. The illumination of PIV particles and excitation of PLIF dye are achieved by a dual-head pulsed Nd:YAG laser and two CCD cameras with a set of optical filters. The procedure for matching refractive indexes of two fluids and calibration of the combined system are presented, as well as a quantitative analysis of the measurement uncertainties. The flow structures and mixing dynamics within the central vertical plane are studied by examining the averaged parameters, turbulent kinetic energy budget, and modeling of momentum flux and buoyancy flux. At downstream, profiles of velocity and density display strong asymmetry with respect to its center. This is attributed to the fact that stable stratification reduces mixing and unstable stratification enhances mixing. In stable stratification region, most of turbulence production is consumed by mean-flow convection, whereas in unstable stratification region, turbulence production is nearly balanced by viscous dissipation. Experimental data also indicate that at downstream locations, mixing length model performs better in mixing zone of stable stratification regions, whereas in other regions, eddy viscosity/diffusivity models with static model coefficients represent effectively momentum and buoyancy flux terms. The measured turbulent Prandtl number displays strong spatial variation in the stratified jet.

  9. Airborne Atmospheric Aerosol Measurement System

    Science.gov (United States)

    Ahn, K.; Park, Y.; Eun, H.; Lee, H.

    2015-12-01

    It is important to understand the atmospheric aerosols compositions and size distributions since they greatly affect the environment and human health. Particles in the convection layer have been a great concern in global climate changes. To understand these characteristics satellite, aircraft, and radio sonde measurement methods have usually been used. An aircraft aerosol sampling using a filter and/or impactor was the method commonly used (Jay, 2003). However, the flight speed particle sampling had some technical limitations (Hermann, 2001). Moreover, the flight legal limit, altitude, prohibited airspace, flight time, and cost was another demerit. To overcome some of these restrictions, Tethered Balloon Package System (T.B.P.S.) and Recoverable Sonde System(R.S.S.) were developed with a very light optical particle counter (OPC), impactor, and condensation particle counter (CPC). Not only does it collect and measure atmospheric aerosols depending on altitudes, but it also monitors the atmospheric conditions, temperature, humidity, wind velocity, pressure, GPS data, during the measurement (Eun, 2013). In this research, atmospheric aerosol measurement using T.B.P.S. in Ansan area is performed and the measurement results will be presented. The system can also be mounted to an unmanned aerial vehicle (UAV) and create an aerial particle concentration map. Finally, we will present measurement data using Tethered Balloon Package System (T.B.P.S.) and R.S.S (Recoverable Sonde System).

  10. Existence of time-dependent density-functional theory for open electronic systems: time-dependent holographic electron density theorem.

    Science.gov (United States)

    Zheng, Xiao; Yam, ChiYung; Wang, Fan; Chen, GuanHua

    2011-08-28

    We present the time-dependent holographic electron density theorem (TD-HEDT), which lays the foundation of time-dependent density-functional theory (TDDFT) for open electronic systems. For any finite electronic system, the TD-HEDT formally establishes a one-to-one correspondence between the electron density inside any finite subsystem and the time-dependent external potential. As a result, any electronic property of an open system in principle can be determined uniquely by the electron density function inside the open region. Implications of the TD-HEDT on the practicality of TDDFT are also discussed.

  11. Study of density field measurement based on NPLS technique in supersonic flow

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Due to the influence of shock wave and turbulence, supersonic density field exhibits strongly inhomogeneous and unsteady characteristics. Applying traditional density field measurement techniques to supersonic flows yields three problems: low spatiotemporal resolution, limitation of measuring 3D density field, and low signal to noise ratio (SNR). A new method based on Nano-based Planar Laser Scattering (NPLS) technique is proposed in this paper to measure supersonic density field. This method measures planar transient density field in 3D supersonic flow by calibrating the relationship between density and concentration of tracer particles, which would display the density fluctuation due to the influence of shock waves and vortexes. The application of this new method to density field measurement of supersonic optical bow cap is introduced in this paper, and the results reveal shock wave, turbulent boundary layer in the flow with the spatial resolution of 93.2 μm/pixel. By analyzing the results at interval of 5 μs, temporal evolution of density field can be observed.

  12. Study of density field measurement based on NPLS technique in supersonic flow

    Institute of Scientific and Technical Information of China (English)

    TIAN LiFeng; YI ShiHe; ZHAO YuXin; HE Lin; CHENG ZhongYu

    2009-01-01

    Due to the influence of shock wave and turbulence,supersonic density field exhibits strongly inho-mogeneous and unsteady characteristics.Applying traditional density field measurement techniques to supersonic flows yields three problems: low spatiotemporal resolution,limitation of measuring 3D density field,and low signal to noise ratio (SNR).A new method based on Nano-based Planar Laser Scattering (NPLS) technique is proposed in this paper to measure supersonic density field.This method measures planar transient density field in 3D supersonic flow by calibrating the relationship between density and concentration of tracer particles,which would display the density fluctuation due to the influence of shock waves and vortexes.The application of this new method to density field measurement of supersonic optical bow cap is introduced in this paper,and the results reveal shock wave,turbulent boundary layer in the flow with the spatial resolution of 93.2 pm/pixel.By analyzing the results at interval of 5 μs,temporal evolution of density field can be observed.

  13. Exchange Flow Rate Measurement Technique in Density Different Gases

    Directory of Open Access Journals (Sweden)

    Motoo Fumizawa

    2012-04-01

    Full Text Available Buoyancy-driven exchange flows of helium-air through inclined a narrow tube was investigated. Exchange flows may occur following the opening of a window for ventilation, as well as when a pipe ruptures in a high temperature gas-cooled reactor. The experiment in this paper was carried out in a test chamber filled with helium and the flow was visualized using the smoke wire method. A high-speed camera recorded the flow behavior. The image of the flow was transferred to digital data, and the slow flow velocity, i.e. micro flow rate was measured by PIV software. Numerical simulation was carried out by the code of moving particle method with Lagrange method.

  14. Elasticity-density and viscoelasticity-density relationships at the tibia mid-diaphysis assessed from resonant ultrasound spectroscopy measurements.

    Science.gov (United States)

    Bernard, Simon; Schneider, Joannes; Varga, Peter; Laugier, Pascal; Raum, Kay; Grimal, Quentin

    2016-02-01

    Cortical bone tissue is an anisotropic material characterized by typically five independent elastic coefficients (for transverse isotropy) governing shear and longitudinal deformations in the different anatomical directions. It is well established that the Young's modulus in the direction of the bone axis of long bones has a strong relationship with mass density. It is not clear, however, whether relationships of similar strength exist for the other elastic coefficients, for they have seldom been investigated, and the results available in the literature are contradictory. The objectives of the present work were to document the anisotropic elastic properties of cortical bone at the tibia mid-diaphysis and to elucidate their relationships with mass density. Resonant ultrasound spectroscopy (RUS) was used to measure the transverse isotropic stiffness tensor of 55 specimens from 19 donors. Except for Poisson's ratios and the non-diagonal stiffness coefficient, strong linear correlations between the different elastic coefficients (0.7 tibia. RUS also measures the viscous part of the stiffness tensor. An anisotropy ratio close to two was found for damping coefficients. Damping increased as the mass density decreased. The data suggest that a relatively accurate estimation of all the mid-tibia elastic coefficients can be derived from mass density. This is of particular interest (1) to design organ-scale bone models in which elastic coefficients are mapped according to Hounsfield values from computed tomography scans as a surrogate for mass density and (2) to model ultrasound propagation at the mid-tibia, which is an important site for the in vivo assessment of bone status with axial transmission techniques.

  15. Large density amplification measured on jets ejected from a magnetized plasma gun

    OpenAIRE

    Yun, Gunsu S.; You, Setthivoine; Bellan, Paul M.

    2007-01-01

    Observation of a large density amplification in the collimating plasma jet ejected from a coplanar coaxial plasma gun is reported. The jet velocity is ~30 km s^-1 and the electron density increases from ~10^20 to 10^(22–23) m^-3. In previous spheromak experiments, electron density of the order 10^(19–21) m^-3 had been measured in the flux conserver region, but no density measurement had been reported for the source gun region. The coplanar geometry of our electrodes permits direct observation...

  16. Separate density and viscosity measurements of unknown liquid using quartz crystal microbalance

    Directory of Open Access Journals (Sweden)

    Feng Tan

    2016-09-01

    Full Text Available Aqueous liquids have a wide range of applications in many fields. Basic physical properties like the density and the viscosity have great impacts on the functionalities of a given ionic liquid. For the millions kinds of existing liquids, only a few have been systematically measured with the density and the viscosity using traditional methods. However, these methods are limited to measure the density and the viscosity of an ionic liquid simultaneously especially in processing micro sample volumes. To meet this challenge, we present a new theoretical model and a novel method to separate density and viscosity measurements with single quartz crystal microbalance (QCM in this work. The agreement of experimental results and theocratical calculations shows that the QCM is capable to measure the density and the viscosity of ionic liquids.

  17. Density-functional formula for strongly correlated systems

    Institute of Scientific and Technical Information of China (English)

    WANG Huaiyu; HAN Rushan; CHEN Nanxian

    2005-01-01

    Density functional method is applied for strongly correlated systems. Based on the assumption that the systems are composed of electrons in singly-occupied orbitals and those in doubly-occupied orbitals, a set of self-consistent equations are obtained by standard variation procedure. The equations consist of two parts. One part is to solve the wave functions of the electrons in singly-occupied orbitals and the other is to solve the wave functions of the electrons in doubly-occupied orbitals. The physical meanings of the terms appearing in the equations are discussed.

  18. HLS bunch current measurement system

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Bunch current is an important parameter for studying the injection fill-pattern in the storage ring and the instability threshold of the bunch, and the bunch current monitor also is an indispensable tool for the top-up injection. A bunch current measurement (BCM) system has been developed to meet the needs of the upgrade project of Hefei Light Source (HLS). This paper presents the layout of the BCM system. The system based on a high-speed digital oscilloscope can be used to measure the bunch current and synchronous phase shift. To obtain the absolute value of bunch-by-bunch current, the calibration coefficient is measured and analyzed. Error analysis shows that the RMS of bunch current is less than 0.01 mA when bunch current is about 5 mA, which can meet project requirement.

  19. Numerical shadows: measures and densities on the numerical range

    CERN Document Server

    Dunkl, Charles F; Holbrook, John A; Puchała, Zbigniew; Zyczkowski, Karol \\

    2010-01-01

    For any operator $M$ acting on an $N$-dimensional Hilbert space $H_N$ we introduce its numerical shadow, which is a probability measure on the complex plane supported by the numerical range of $M$. The shadow of $M$ at point $z$ is defined as the probability that the inner product $(Mu,u)$ is equal to $z$, where $u$ stands for a random complex vector from $H_N$, satisfying $||u||=1$. In the case of N=2 the numerical shadow of a non-normal operator can be interpreted as a shadow of a hollow sphere projected on a plane. A similar interpretation is provided also for higher dimensions. For a hermitian $M$ its numerical shadow forms a probability distribution on the real axis which is shown to be a one dimensional $B$-spline. In the case of a normal $M$ the numerical shadow corresponds to a shadow of a transparent solid simplex in $R^{N-1}$ onto the complex plane. Numerical shadow is found explicitly for Jordan matrices $J_N$, direct sums of matrices and in all cases where the shadow is rotation invariant. Results...

  20. 宽量程中子通量密度测量数字化处理系统设计%Design of Wide Range Digital Processing System for Neutron Flux Density Measurement

    Institute of Scientific and Technical Information of China (English)

    袁超; 黄跃峰; 李勇平

    2015-01-01

    The real-time and accurate measurement of reactor neutron flux is directly related to safe operation of the reactor.Neutron flux measurement system with fission chamber based on the analog technology had some shortage, a fission chamber of digital output signal processing system was designed.The combination of two kinds of fission chamber working mode which is pulse and Campbell were applied in this system.Using high-speed ADC digitalized signal from the fission chamber, FPGA could be used in a variety of digital signal pro-cessing algorithms.And using MATLAB simulated output pulse signal of the fission chamber, which imported arbitrary waveform signal generator as neutron source, to be used in a preliminary validation of the algorithm. Test results showed that the digital processing system had good linearity and good performance.%实时准确地测量反应堆的中子通量变化状况,对于确保反应堆的安全运行有着重要意义。基于模拟测量系统存在的一些不足,设计一种数字化的宽量程裂变室输出信号处理系统。该数字化信号处理系统将裂变室的脉冲和坎贝尔两种工作模式相结合,利用高速ADC对裂变室输出脉冲信号数字化,在FPGA中运用数字信号处理算法实现两种工作模式的信号处理,并仿真了裂变室的输出脉冲信号导入任意波形信号发生器模拟中子信号源,用于对处理算法的初步验证。测试结果表明数字化处理系统线性度和性能良好。

  1. Blood Density Is Nearly Equal to Water Density: A Validation Study of the Gravimetric Method of Measuring Intraoperative Blood Loss.

    Science.gov (United States)

    Vitello, Dominic J; Ripper, Richard M; Fettiplace, Michael R; Weinberg, Guy L; Vitello, Joseph M

    2015-01-01

    Purpose. The gravimetric method of weighing surgical sponges is used to quantify intraoperative blood loss. The dry mass minus the wet mass of the gauze equals the volume of blood lost. This method assumes that the density of blood is equivalent to water (1 gm/mL). This study's purpose was to validate the assumption that the density of blood is equivalent to water and to correlate density with hematocrit. Methods. 50 µL of whole blood was weighed from eighteen rats. A distilled water control was weighed for each blood sample. The averages of the blood and water were compared utilizing a Student's unpaired, one-tailed t-test. The masses of the blood samples and the hematocrits were compared using a linear regression. Results. The average mass of the eighteen blood samples was 0.0489 g and that of the distilled water controls was 0.0492 g. The t-test showed P = 0.2269 and R (2) = 0.03154. The hematocrit values ranged from 24% to 48%. The linear regression R (2) value was 0.1767. Conclusions. The R (2) value comparing the blood and distilled water masses suggests high correlation between the two populations. Linear regression showed the hematocrit was not proportional to the mass of the blood. The study confirmed that the measured density of blood is similar to water.

  2. Highly Sensitive Measurement of Liquid Density in Air Using Suspended Microcapillary Resonators

    Directory of Open Access Journals (Sweden)

    Oscar Malvar

    2015-03-01

    Full Text Available We report the use of commercially available glass microcapillaries as micromechanical resonators for real-time monitoring of the mass density of a liquid that flows through the capillary. The vibration of a suspended region of the microcapillary is optically detected by measuring the forward scattering of a laser beam. The resonance frequency of the liquid filled microcapillary is measured for liquid binary mixtures of ethanol in water, glycerol in water and Triton in ethanol. The method achieves a detection limit in an air environment of 50 µg/mL that is only five times higher than that obtained with state-of-the-art suspended microchannel resonators encapsulated in vacuum. The method opens the door to novel advances for miniaturized total analysis systems based on microcapillaries with the add-on of mechanical transduction for sensing the rheological properties of the analyzed fluids without the need for vacuum encapsulation of the resonators.

  3. Highly Sensitive Measurement of Liquid Density in Air Using Suspended Microcapillary Resonators

    Science.gov (United States)

    Malvar, Oscar; Ramos, Daniel; Martínez, Carmen; Kosaka, Priscila; Tamayo, Javier; Calleja, Montserrat

    2015-01-01

    We report the use of commercially available glass microcapillaries as micromechanical resonators for real-time monitoring of the mass density of a liquid that flows through the capillary. The vibration of a suspended region of the microcapillary is optically detected by measuring the forward scattering of a laser beam. The resonance frequency of the liquid filled microcapillary is measured for liquid binary mixtures of ethanol in water, glycerol in water and Triton in ethanol. The method achieves a detection limit in an air environment of 50 µg/mL that is only five times higher than that obtained with state-of-the-art suspended microchannel resonators encapsulated in vacuum. The method opens the door to novel advances for miniaturized total analysis systems based on microcapillaries with the add-on of mechanical transduction for sensing the rheological properties of the analyzed fluids without the need for vacuum encapsulation of the resonators. PMID:25831083

  4. Measurement of mobile antenna systems

    CERN Document Server

    Arai, Hiroyuki

    2012-01-01

    If you're involved with the design, installation or maintenance of mobile antenna systems, this thoroughly revised and updated edition of a classic Artech book offers you the most current and comprehensive coverage of all the mandatory measurement techniques you need for your work in the field. This Second Edition presents critical new material in key areas, including radiation efficiency measurement, mobile phone usage position, and MIMO (multiple-input/multiple-output) antennas.This unique resource provides in-depth examinations of all relevant mobile antenna measurement theories, along with

  5. Microelectromechanical high-density energy storage/rapid release system

    Science.gov (United States)

    Rodgers, M. Steven; Allen, James J.; Meeks, Kent D.; Jensen, Brian D.; Miller, Samuel L.

    1999-08-01

    One highly desirable characteristic of electrostatically driven microelectromechanical systems (MEMS) is that they consume very little power. The corresponding drawback is that the force they produce may be inadequate for many applications. It has previously been demonstrated that gear reduction units or microtransmissions can substantially increase the torque generated by microengines. Operating speed, however, is also reduced by the transmission gear ratio. Some applications require both high speed and high force. If this output is only required for a limited period of time, then energy could be stored in a mechanical system and rapidly released upon demand. We have designed, fabricated, and demonstrated a high-density energy storage/rapid release system that accomplishes this task. Built using a 5-level surface micromachining technology, the assembly closely resembles a medieval crossbow. Energy releases on the order of tens of nanojoules have already been demonstrated, and significantly higher energy systems are under development.

  6. Lack of correlation of glucose levels in filtered blood plasma to density and conductivity measurements.

    Science.gov (United States)

    Gordon, David M; Ash, Stephen R

    2009-01-01

    The purpose of this research project was to determine whether the glucose level of a blood plasma sample from a diabetic patient could be predicted by measuring the density and conductivity of ultrafiltrate of plasma created by a 30,000 m.w. cutoff membrane. Conductivity of the plasma filtrate measures electrolyte concentration and should correct density measurements for changes in electrolytes and water concentration. In vitro studies were performed measuring conductivity and density of solutions of varying glucose and sodium chloride concentrations. Plasma from seven hospitalized patients with diabetes was filtered across a 30,000 m.w. cutoff membrane. The filtrate density and conductivity were measured and correlated to glucose levels. In vitro studies confirmed the ability to predict glucose from density and conductivity measurements, in varying concentrations of glucose and saline. In plasma filtrate, the conductivity and density measurements of ultrafiltrate allowed estimation of glucose in some patients with diabetes but not others. The correlation coefficient for the combined patient data was 0.45 which was significant but only explained 20% of the variability in the glucose levels. Individually, the correlation was significant in only two of the seven patients with correlation coefficients of 0.79 and 0.88. The reasons for lack of correlation are not clear, and cannot be explained by generation of idiogenic osmoles, effects of alcohol dehydrogenase, water intake, etc. This combination of physical methods for glucose measurement is not a feasible approach to measuring glucose in plasma filtrate.

  7. Interrupted orbital motion in density-wave systems

    Science.gov (United States)

    Breitkreiz, Maxim; Brydon, P. M. R.; Timm, Carsten

    2016-11-01

    In conventional metals, electronic transport in a magnetic field is characterized by the motion of electrons along orbits on the Fermi surface, which usually causes an increase in the resistivity through averaging over velocities. Here, we show that large deviations from this behavior can arise in density-wave systems close to their ordering temperature. Specifically, enhanced scattering off collective fluctuations can lead to a change of direction of the orbital motion on reconstructed pockets. In weak magnetic fields, this leads to linear magnetoconductivity, the sign of which depends on the electric-field direction. At a critical magnetic field, the conductivity crosses zero for certain directions, signifying a thermodynamic instability of the density-wave state.

  8. Density Measurements of Na2WO4-WO3-ZnO Melts

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Based on Archimedes principle, the densities of Na2WO4-WO3-ZnO melts at a fixed mole ratio of 3.43 of Na2WO4 to ZnO were measured. The results indicated that there was a linear relationship between the densities and temperatures at a fixed composition. At a fixed temperature, the linear relationship between densities and compositions showed different slop within different composition regions. The reasons were explained in view of ionic composition changes.

  9. 3-D density imaging with muon flux measurements from underground galleries

    Science.gov (United States)

    Lesparre, N.; Cabrera, J.; Marteau, J.

    2017-03-01

    Atmospheric muon flux measurements provide information on subsurface density distribution. In this study, muon flux was measured underground, in the Tournemire experimental platform (France). The objective was to image the medium between the galleries and the surface and evaluate the feasibility to detect the presence of discontinuities, for example, produced by secondary subvertical faults or by karstic networks. Measurements were performed from three different sites with a partial overlap of muon trajectories, offering the possibility to seek density variations at different depths. The conversion of the measured muon flux to average density values showed global variations further analysed through a 3-D nonlinear inversion procedure. Main results are the presence of a very low density region at the level of the upper aquifer, compatible with the presence of a karstic network hosting local cavities, and the absence of secondary faults. We discuss the validity of the present results and propose different strategies to improve the accuracy of such measurements and analysis.

  10. Breast density mapping based upon system calibration, x-ray techniques, and FFDM images

    Science.gov (United States)

    Chen, Biao; Smith, Andrew P.; Jing, Zhenxue; Wu, Tao

    2007-03-01

    Clinical studies have correlated a high breast density to a women's risk of breast cancer. A breast density measurement that can quantitatively depict the volume distribution and percentage of dense tissues in breasts would be very useful for risk factor assessment of breast cancer, and might be more predictive of risks than the common but subjective and coarse 4-point BIRADS scale. This paper proposes to use a neural-network mapping to compute the breast density information based upon system calibration data, x-ray techniques, and Full Field Digital Mammography (FFDM) images. The mapping consists of four modules, namely, system calibration, generator of beam quality, generator of normalized absorption, and a multi-layer feed-forward neural network. As the core of breast density mapping, the network accepts x-ray target/filter combination, normalized x-ray absorption, pixel-wise breast thickness map, and x-ray beam quality during image acquisition as input elements, and exports a pixel-wise breast density distribution and a single breast density percentage for the imaged breast. Training and testing data sets for the design and verification of the network were formulated from calibrated x-ray beam quality, imaging data with a step wedge phantom under a variety x-ray imaging techniques, and nominal breast densities of tissue equivalent materials. The network was trained using a Levenberg-Marquardt algorithm based back-propagation learning method. Various thickness and glandular density phantom studies were performed with clinical x-ray techniques. Preliminary results showed that the neural network mapping is promising in accurately computing glandular density distribution and breast density percentage.

  11. A study of increasing radical density and etch rate using remote plasma generator system

    Science.gov (United States)

    Lee, Jaewon; Kim, Kyunghyun; Cho, Sung-Won; Chung, Chin-Wook

    2013-09-01

    To improve radical density without changing electron temperature, remote plasma generator (RPG) is applied. Multistep dissociation of the polyatomic molecule was performed using RPG system. RPG is installed to inductively coupled type processing reactor; electrons, positive ions, radicals and polyatomic molecule generated in RPG and they diffused to processing reactor. The processing reactor dissociates the polyatomic molecules with inductively coupled power. The polyatomic molecules are dissociated by the processing reactor that is operated by inductively coupled power. Therefore, the multistep dissociation system generates more radicals than single-step system. The RPG was composed with two cylinder type inductively coupled plasma (ICP) using 400 kHz RF power and nitrogen gas. The processing reactor composed with two turn antenna with 13.56 MHz RF power. Plasma density, electron temperature and radical density were measured with electrical probe and optical methods.

  12. Continuous plasma density measurement in TJ-II infrared interferometer-Advanced signal processing based on FPGAs

    Energy Technology Data Exchange (ETDEWEB)

    Esteban, L., E-mail: luis.esteban-hernandez@ciemat.e [Laboratorio Nacional de Fusion, Asociacion EURATOM-CIEMAT, Avenida Complutense No. 22, E-28040 Madrid (Spain); Sanchez, M. [Laboratorio Nacional de Fusion, Asociacion EURATOM-CIEMAT, Avenida Complutense No. 22, E-28040 Madrid (Spain); Lopez, J.A.; Nieto-Taladriz, O. [Departamento de Ingeniera Electronica, ETSI Telecomunicacion, Universidad Politcnica de Madrid, Avenida Complutense No. 30, E-28040 Madrid (Spain); Sanchez, J. [Laboratorio Nacional de Fusion, Asociacion EURATOM-CIEMAT, Avenida Complutense No. 22, E-28040 Madrid (Spain)

    2010-07-15

    This work presents the behavioral simulation in an FPGA of a novel processing system for measuring line average electronic density in the TJ-II stellarator diagnostic, Infra-Red Two-Color Interferometer. Line average electronic density is proportional to phase difference between probing and reference signals of the interferometer, as the Appleton-Hartree cold plasma model states. The novelty of the approach is the development of a real time measuring system where research work has been carried out in two ways: a new interpolation algorithm and the implementation of a new specific processor on an FPGA. The main goal of this new system is to measure line plasma electronic density for several channels in real time, also it will be useful to eliminate intermediate mixing frequency stages (the output signals coming from the interferometer are going to be directly sampled) and finally to generate real time density signals for control purposes in TJ-II and in other diagnostics. This device is intended to be the new data acquisition-processing system for the future six channel infrared interferometer that requires at least 14 input signals. The knowledge acquired could be useful in the design of W7-X and ITER IR-interferometer data acquisition and processing systems.

  13. A New Measurement of the Electron Density in the Local Interstellar Medium

    Science.gov (United States)

    Wood, Brian E.; Linsky, Jeffrey L.

    1997-01-01

    Using the echelle-A grating of the Goddard High-Resolution Spectrograph, we have observed the C II λλ1335, 1336 emission lines of the nearby (d = 13.3 pc) star system Capella (G8 III + G1 III). Interstellar C II absorption features are detected within both stellar emission lines. The ground-state and excited-state C II column densities derived from these absorption lines imply an electron density of ne = 0.11+0.12-0.06 cm-3 in the local interstellar medium (LISM). Unlike previous derivations of ne from Mg II/Mg I ratios, the density suggested by the C II lines is independent of assumptions about ionization equilibrium. Current estimates of the H I density in the LISM are in the range 0.1-0.2 cm-3. The He I/H I ratio toward the white dwarf G191-B2B, which is only 7° from Capella, has been measured to be He I/H I = 0.068-0.082 from the Extreme-Ultraviolet Explorer data. These results indicate hydrogen and helium ionization fractions toward Capella of X(H) = 0.45 +/- 0.25 and X(He) = 0.57 +/- 0.23, respectively, confirming that hydrogen and helium are substantially ionized in the LISM. Based on observations with the NASA/ESA Hubble Space Telescope, obtained at the Space Telescope Science Institute, which is operated by the Association of Universities for Research in Astronomy Inc., under NASA contract NAS5-26555.

  14. Comparison of subjective and fully automated methods for measuring mammographic density.

    Science.gov (United States)

    Moshina, Nataliia; Roman, Marta; Sebuødegård, Sofie; Waade, Gunvor G; Ursin, Giske; Hofvind, Solveig

    2017-01-01

    Background Breast radiologists of the Norwegian Breast Cancer Screening Program subjectively classified mammographic density using a three-point scale between 1996 and 2012 and changed into the fourth edition of the BI-RADS classification since 2013. In 2015, an automated volumetric breast density assessment software was installed at two screening units. Purpose To compare volumetric breast density measurements from the automated method with two subjective methods: the three-point scale and the BI-RADS density classification. Material and Methods Information on subjective and automated density assessment was obtained from screening examinations of 3635 women recalled for further assessment due to positive screening mammography between 2007 and 2015. The score of the three-point scale (I = fatty; II = medium dense; III = dense) was available for 2310 women. The BI-RADS density score was provided for 1325 women. Mean volumetric breast density was estimated for each category of the subjective classifications. The automated software assigned volumetric breast density to four categories. The agreement between BI-RADS and volumetric breast density categories was assessed using weighted kappa (kw). Results Mean volumetric breast density was 4.5%, 7.5%, and 13.4% for categories I, II, and III of the three-point scale, respectively, and 4.4%, 7.5%, 9.9%, and 13.9% for the BI-RADS density categories, respectively ( P for trend density categories was kw = 0.5 (95% CI = 0.47-0.53; P density increased with increasing density category of the subjective classifications. The agreement between BI-RADS and volumetric breast density categories was moderate.

  15. Vapour pressures, densities, and viscosities of the (water + lithium bromide + potassium acetate) system and (water + lithium bromide + sodium lactate) system

    Energy Technology Data Exchange (ETDEWEB)

    Lucas, Antonio de [Department of Chemical Engineering, University of Castilla - La Mancha, Avda. de Camilo Jose Cela s/n, 13004 Ciudad Real (Spain); Donate, Marina [Department of Chemical Engineering, University of Castilla - La Mancha, Avda. de Camilo Jose Cela s/n, 13004 Ciudad Real (Spain); Rodriguez, Juan F. [Department of Chemical Engineering, University of Castilla - La Mancha, Avda. de Camilo Jose Cela s/n, 13004 Ciudad Real (Spain)]. E-mail: juan.rromero@uclm.es

    2006-02-15

    Measurements of thermophysical properties (vapour pressure, density, and viscosity) of the (water + lithium bromide + potassium acetate) system LiBr:CH{sub 3}COOK = 2:1 by mass ratio and the (water + lithium bromide + sodium lactate) system LiBr:CH{sub 3}CH(OH)COONa = 2:1 by mass ratio were measured. The system, a possible new working fluid for absorption heat pump, consists of absorbent (LiBr + CH{sub 3}COOK) or (LiBr + CH{sub 3}CH(OH)COONa) and refrigerant H{sub 2}O. The vapour pressures were measured in the ranges of temperature and absorbent concentration from T = (293.15 to 333.15) K and from mass fraction 0.20 to 0.50, densities and viscosities were measured from T = (293.15 to 323.15) K and from mass fraction 0.20 to 0.40. The experimental data were correlated with an Antoine-type equation. Densities and viscosities were measured in the same range of temperature and absorbent concentration as that of the vapour pressure. Regression equations for densities and viscosities were obtained with a minimum mean square error criterion.

  16. Optical Extinction Measurements of Dust Density in the GMRO Regolith Test Bin

    Science.gov (United States)

    Lane, J.; Mantovani, J.; Mueller, R.; Nugent, M.; Nick, A.; Schuler, J.; Townsend, I.

    2016-01-01

    A regolith simulant test bin was constructed and completed in the Granular Mechanics and Regolith Operations (GMRO) Lab in 2013. This Planetary Regolith Test Bed (PRTB) is a 64 sq m x 1 m deep test bin, is housed in a climate-controlled facility, and contains 120 MT of lunar-regolith simulant, called Black Point-1 or BP-1, from Black Point, AZ. One of the current uses of the test bin is to study the effects of difficult lighting and dust conditions on Telerobotic Perception Systems to better assess and refine regolith operations for asteroid, Mars and polar lunar missions. Low illumination and low angle of incidence lighting pose significant problems to computer vision and human perception. Levitated dust on Asteroids interferes with imaging and degrades depth perception. Dust Storms on Mars pose a significant problem. Due to these factors, the likely performance of telerobotics is poorly understood for future missions. Current space telerobotic systems are only operated in bright lighting and dust-free conditions. This technology development testing will identify: (1) the impact of degraded lighting and environmental dust on computer vision and operator perception, (2) potential methods and procedures for mitigating these impacts, (3) requirements for telerobotic perception systems for asteroid capture, Mars dust storms and lunar regolith ISRU missions. In order to solve some of the Telerobotic Perception system problems, a plume erosion sensor (PES) was developed in the Lunar Regolith Simulant Bin (LRSB), containing 2 MT of JSC-1a lunar simulant. PES is simply a laser and digital camera with a white target. Two modes of operation have been investigated: (1) single laser spot - the brightness of the spot is dependent on the optical extinction due to dust and is thus an indirect measure of particle number density, and (2) side-scatter - the camera images the laser from the side, showing beam entrance into the dust cloud and the boundary between dust and void. Both

  17. Measurements relating fire radiative energy density and surface fuel consumption - RxCADRE 2011 and 2012

    Science.gov (United States)

    Andrew T. Hudak; Matthew B. Dickinson; Benjamin C. Bright; Robert L. Kremens; E. Louise Loudermilk; Joseph J. O' Brien; Benjamin S. Hornsby; Roger D. Ottmar

    2016-01-01

    Small-scale experiments have demonstrated that fire radiative energy is linearly related to fuel combusted but such a relationship has not been shown at the landscape level of prescribed fires. This paper presents field and remotely sensed measures of pre-fire fuel loads, consumption, fire radiative energy density (FRED) and fire radiative power flux density (FRFD),...

  18. Measurement of Plasma Density Produced in Dielectric Barrier Discharge for Active Aerodynamic Control with Interferometer

    Institute of Scientific and Technical Information of China (English)

    LI Gang; ZHANG Yi; XU Yan-Ji; LIN Bin; LI Yu-Tong; ZHU Jun-Qiang

    2009-01-01

    We utilize an interferometer to investigate the changes of the refractive index caused by dielectric barrier discharge plasma.The electronic density of the plasma produced is measured and analyzed tentatively.The results show that density of the plasma increases linearly with exciting voltages.

  19. Improved density profile measurements in the C-2U advanced beam-driven Field-Reversed Configuration (FRC) plasmas

    Science.gov (United States)

    Beall, M.; Deng, B. H.; Gota, H.

    2016-11-01

    In the prior C-2 experiment, electron density was measured using a two-color 6-chord CO2/HeNe interferometer. Analysis shows that high-frequency common mode phase noise can be reduced by a factor of 3 by constructing a reference chord. In the system upgrade from C-2 to C-2U a 4-chord far-infrared laser interferometer was developed, which demonstrated superior sensitivity (1 × 1016 m-2 at >1 MHz bandwidth) and solved the under spatial sampling issue of the C-2 interferometer system. Improved density-profile measurement results are presented in this paper, including evidence of fast-ion modified density profile and stabilization of the n = 1 plasma wobble mode.

  20. High-resolution Tangential AXUV Arrays for Radiated Power Density Measurements on NSTX-U

    Energy Technology Data Exchange (ETDEWEB)

    Delgado-Aparicio, L [PPPL; Bell, R E [PPPL; Faust, I [MIT; Tritz, K [The Johns Hopkins University, Baltimore, MD, 21209, USA; Diallo, A [PPPL; Gerhardt, S P [PPPL; Kozub, T A [PPPL; LeBlanc, B P [PPPL; Stratton, B C [PPPL

    2014-07-01

    Precise measurements of the local radiated power density and total radiated power are a matter of the uttermost importance for understanding the onset of impurity-induced instabilities and the study of particle and heat transport. Accounting of power balance is also needed for the understanding the physics of various divertor con gurations for present and future high-power fusion devices. Poloidal asymmetries in the impurity density can result from high Mach numbers and can impact the assessment of their flux-surface-average and hence vary the estimates of P[sub]rad (r, t) and (Z[sub]eff); the latter is used in the calculation of the neoclassical conductivity and the interpretation of non-inductive and inductive current fractions. To this end, the bolometric diagnostic in NSTX-U will be upgraded, enhancing the midplane coverage and radial resolution with two tangential views, and adding a new set of poloidally-viewing arrays to measure the 2D radiation distribution. These systems are designed to contribute to the near- and long-term highest priority research goals for NSTX-U which will integrate non-inductive operation at reduced collisionality, with high-pressure, long energy-confinement-times and a divertor solution with metal walls.

  1. MAX-DOAS measurements of NO2 column densities in Vienna

    Science.gov (United States)

    Schreier, Stefan; Weihs, Philipp; Peters, Enno; Richter, Andreas; Ostendorf, Mareike; Schönhardt, Anja; Burrows, John P.; Schmalwieser, Alois

    2017-04-01

    In the VINDOBONA (VIenna horizontal aNd vertical Distribution OBservations Of Nitrogen dioxide and Aerosols) project, two Multi AXis Differential Optical Absorption Spectroscopy (MAX-DOAS) systems will be set up at two different locations and altitudes in Vienna, Austria. After comparison measurements in Bremen, Germany, and Cabauw, The Netherlands, the first of the two MAX-DOAS instruments was set up at the University of Veterinary Medicine in the northeastern part of Vienna in December 2016. The instrument performs spectral measurements of visible scattered sunlight at defined horizontal and vertical viewing directions. From these measurements, column densities of NO2 and aerosols are derived by applying the DOAS analysis. First preliminary results are presented. The second MAX-DOAS instrument will be set up in April/May 2017 at the University of Natural Resources and Life Sciences in the northwestern part of Vienna. Once these two instruments are measuring simultaneously, small campaigns including car DOAS zenith-sky and tower DOAS off-axis measurements are planned. The main emphasis of this project will be on the installation and operation of two MAX-DOAS instruments, the improvement of tropospheric NO2 and aerosol retrieval, and the characterization of the horizontal, vertical, and temporal variations of tropospheric NO2 and aerosols in Vienna, Austria.

  2. Methods and systems for rapid prototyping of high density circuits

    Science.gov (United States)

    Palmer, Jeremy A.; Davis, Donald W.; Chavez, Bart D.; Gallegos, Phillip L.; Wicker, Ryan B.; Medina, Francisco R.

    2008-09-02

    A preferred embodiment provides, for example, a system and method of integrating fluid media dispensing technology such as direct-write (DW) technologies with rapid prototyping (RP) technologies such as stereolithography (SL) to provide increased micro-fabrication and micro-stereolithography. A preferred embodiment of the present invention also provides, for example, a system and method for Rapid Prototyping High Density Circuit (RPHDC) manufacturing of solderless connectors and pilot devices with terminal geometries that are compatible with DW mechanisms and reduce contact resistance where the electrical system is encapsulated within structural members and manual electrical connections are eliminated in favor of automated DW traces. A preferred embodiment further provides, for example, a method of rapid prototyping comprising: fabricating a part layer using stereolithography and depositing thermally curable media onto the part layer using a fluid dispensing apparatus.

  3. Greenland annual accumulation along the EGIG line, 1959-2004, from ASIRAS airborne radar and neutron-probe density measurements

    Science.gov (United States)

    Overly, Thomas B.; Hawley, Robert L.; Helm, Veit; Morris, Elizabeth M.; Chaudhary, Rohan N.

    2016-08-01

    We report annual snow accumulation rates from 1959 to 2004 along a 250 km segment of the Expéditions Glaciologiques Internationales au Groenland (EGIG) line across central Greenland using Airborne SAR/Interferometric Radar Altimeter System (ASIRAS) radar layers and high resolution neutron-probe (NP) density profiles. ASIRAS-NP-derived accumulation rates are not statistically different (95 % confidence interval) from in situ EGIG accumulation measurements from 1985 to 2004. ASIRAS-NP-derived accumulation increases by 20 % below 3000 m elevation, and increases by 13 % above 3000 m elevation for the period 1995 to 2004 compared to 1985 to 1994. Three Regional Climate Models (PolarMM5, RACMO2.3, MAR) underestimate snow accumulation below 3000 m by 16-20 % compared to ASIRAS-NP from 1985 to 2004. We test radar-derived accumulation rates sensitivity to density using modeled density profiles in place of NP densities. ASIRAS radar layers combined with Herron and Langway (1980) model density profiles (ASIRAS-HL) produce accumulation rates within 3.5 % of ASIRAS-NP estimates in the dry snow region. We suggest using Herron and Langway (1980) density profiles to calibrate radar layers detected in dry snow regions of ice sheets lacking detailed in situ density measurements, such as those observed by the Operation IceBridge campaign.

  4. Characterizing Molecular Structure by Combining Experimental Measurements with Density Functional Theory Computations

    Science.gov (United States)

    Lopez-Encarnacion, Juan M.

    2016-06-01

    In this talk, the power and synergy of combining experimental measurements with density functional theory computations as a single tool to unambiguously characterize the molecular structure of complex atomic systems is shown. Here, we bring three beautiful cases where the interaction between the experiment and theory is in very good agreement for both finite and extended systems: 1) Characterizing Metal Coordination Environments in Porous Organic Polymers: A Joint Density Functional Theory and Experimental Infrared Spectroscopy Study 2) Characterization of Rhenium Compounds Obtained by Electrochemical Synthesis After Aging Process and 3) Infrared Study of H(D)2 + Co4+ Chemical Reaction: Characterizing Molecular Structures. J.M. López-Encarnación, K.K. Tanabe, M.J.A. Johnson, J. Jellinek, Chemistry-A European Journal 19 (41), 13646-13651 A. Vargas-Uscategui, E. Mosquera, J.M. López-Encarnación, B. Chornik, R. S. Katiyar, L. Cifuentes, Journal of Solid State Chemistry 220, 17-21

  5. Electron density measurements of a field-reversed configuration plasma using a novel compact ultrastable second-harmonic interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Brandi, F.; Giammanco, F. [Department of Physics, University of Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Harris, W. S.; Roche, T.; Trask, E.; Wessel, F. J. [Department of Physics and Astronomy, University of California, Irvine, California 92697 (United States)

    2009-11-15

    A compact high-sensitivity second-harmonic interferometer for line-integrated electron density measurements on a large plasma machine is presented. The device is based on a fiber coupled near-infrared continuous-wave Nd:YAG laser and is remotely controlled. The performances of the instrument are tested on the Irvine field-reversed configuration machine, and a sensitivity of few 10{sup 14} cm{sup -2} in measuring line integrated electron density is demonstrated with a time resolution of a few microseconds. The interferometer is self calibrated, has an impressive stability, and it does not require any further alignment after proper installation. These features make this device a real turn-key system suitable for electron density measurement in large plasma machines.

  6. NO density and gas temperature measurements in atmospheric pressure nanosecond repetitively pulsed (NRP) discharges by Mid-IR QCLAS

    Science.gov (United States)

    Simeni Simeni, Marien; Stancu, Gabi-Daniel; Laux, Christophe

    2014-10-01

    Nitric oxide is a key species for many processes: in combustion, in human skin physiology... Recently, NO-ground state absolute density measurements produced by atmospheric pressure NRP discharges were carried out in air as a function of the discharge parameters, using Quantum Cascade Laser Absorption Spectroscopy. These measurements were space averaged and performed in the post-discharge region in a large gas volume. Here we present radial profiles of NO density and temperature measured directly in the discharge for different configurations. Small plasma volume and species densities, high temperature and EM noise environment make the absorption diagnostic challenging. For this purpose the QCLAS sensitivity was improved using a two-detector system. We conducted lateral absorbance measurements with a spatial resolution of 300 μm for two absorption features at 1900.076 and 1900.517 cm-1. The radial temperature and NO density distributions were obtained from the Abel inverted lateral measurements. Time averaged NO densities of about 1.E16 cm-3 and gas temperature of about 1000K were obtained in the center of the discharge. PLASMAFLAME Project (Grant No ANR-11-BS09-0025).

  7. Application of Density Functional Theory to Systems Containing Metal Atoms

    Science.gov (United States)

    Bauschlicher, Charles W., Jr.

    2006-01-01

    The accuracy of density functional theory (DFT) for problems involving metal atoms is considered. The DFT results are compared with experiment as well as results obtained using the coupled cluster approach. The comparisons include geometries, frequencies, and bond energies. The systems considered include MO2, M(OH)+n, MNO+, and MCO+2. The DFT works well for frequencies and geometries, even in case with symmetry breaking; however, some examples have been found where the symmetry breaking is quite severe and the DFT methods do not work well. The calculation of bond energies is more difficult and examples of successes as well as failures of DFT will be given.

  8. A multi-wavelength, high-contrast contact radiography system for the study of low-density aerogel foams.

    Science.gov (United States)

    Opachich, Y P; Koch, J A; Haugh, M J; Romano, E; Lee, J J; Huffman, E; Weber, F A; Bowers, J W; Benedetti, L R; Wilson, M; Prisbrey, S T; Wehrenberg, C E; Baumann, T F; Lenhardt, J M; Cook, A; Arsenlis, A; Park, H-S; Remington, B A

    2016-07-01

    A multi-wavelength, high contrast contact radiography system has been developed to characterize density variations in ultra-low density aerogel foams. These foams are used to generate a ramped pressure drive in materials strength experiments at the National Ignition Facility and require precision characterization in order to reduce errors in measurements. The system was used to characterize density variations in carbon and silicon based aerogels to ∼10.3% accuracy with ∼30 μm spatial resolution. The system description, performance, and measurement results collected using a 17.8 mg/cc carbon based JX-6 (C20H30) aerogel are discussed in this manuscript.

  9. Density manifolds, geometric measures and high-energy physics in transfinite dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Nada, S.I. [Mathematics Department, Faculty of Science, Qatar University, Doha (Qatar)], E-mail: snada@qu.edu.qa

    2009-11-15

    We discuss certain manifolds with density. Furthermore, we outline natural connections leading to E-infinity theory and high-energy physics from a geometric measure and transfinite dimensional theoretical viewpoints.

  10. Modal decomposition for measuring the orbital angular momentum density of light

    CSIR Research Space (South Africa)

    Schulze, C

    2013-02-01

    Full Text Available We present a novel technique to measure the orbital angular momentum (OAM) density of light. The technique is based on modal decomposition, enabling the complete reconstruction of optical fields, including the reconstruction of the beams Poynting...

  11. Understanding Process Performance Measurement Systems

    Directory of Open Access Journals (Sweden)

    Ljubica MilanoviÊ Glavan

    2011-01-01

    Full Text Available The purpose of this paper is to analyze the current state of Process Performance Measurement Systems (PPMS by means of a systematic review of literature. The PPMS literature is reviewed using a systematic approach. Based on an extensive literature review only twelve articles that contain the term PPMS in the title were found. The literature analysis showed that PPMS is a relatively new topic in the area of performance measurement. In order to understand PPMS, it was crucial to explain the concepts of business process management, business performance measurement and Performance Measurement System (PMS which are well known and used in the literature and practice. PPMS is a special type of PMS that should be used in process-oriented organizations. Limitations of this research lie in the fact that all the conclusions were derived only from the literature, not empirical research. The results presented in the paper continue towards providing an updated overview of the current state of performance measurement, especially PPMS in order to identify the existing research gaps on which ongoing and future research efforts regarding this topic can be focused.

  12. Multichannel Microwave Interferometer for Simultaneous Measurement of Electron Density and its Fluctuation on HL-2A Tokamak

    Science.gov (United States)

    Shi, Peiwan; Shi, Zhongbing; Chen, Wei; Zhong, Wulyu; Yang, Zengchen; Jiang, Min; Zhang, Boyu; Li, Yonggao; Yu, Liming; Liu, Zetian; Ding, Xuantong

    2016-07-01

    A multichannel microwave interferometer system has been developed on the HL-2A tokomak. Its working frequency is well designed to avoid the fringe jump effect. Taking the structure of HL-2A into account, its antennas are installed in the horizontal direction, i.e. one launcher in high field side (HFS) and four receivers in low field side (LFS). The fan-shaped measurement area covers those regions where the magnetohydrodynamics (MHD) instabilities are active. The heterodyne technique contributes to its high temporal resolution (1 μs). It is possible for the multichannel system to realize simultaneous measurements of density and its fluctuation. The quadrature phase detection based on the zero-crossing method is introduced to density measurement. With this system, reliable line-averaged densities and density profiles are obtained. The location of the saturated internal kink mode can be figured out from the mode showing different intensities on four channels, and the result agrees well with that measured by electron cyclotron emission imaging (ECEI). supported by the National Magnetic Confinement Fusion Science Program of China (Nos. 2013GB104002, 2013GB107002, 2014GB107001) and National Natural Science Foundation of China (Nos. 11475058, 11475057, 11261140326, 11405049)

  13. Shock front field structure in low-density systems

    Science.gov (United States)

    Hua, Rui; Mucguffey, Christopher; Beg, Farhat; Sio, Hong; Ping, Yuan; Wilks, Scott; Heeter, Bob; Collins, Rip

    2016-10-01

    It is known that a shock front is not a simple discontinuity in density and temperature as depicted in commonly used hydro codes but also consists of self-generated fields associated with gradients in the electron pressure. A quasi-planar platform using broadband proton radiography has been developed to study this field structure at a shock front. The broad bandwidth offers energy-dependent measurements which quantitatively constrain both the potential and field width at the shock front. Experiments were conducted on the OMEGA EP, where three long pulse beams delivered 6 kJ in 2 ns for shock initiation in a tube filled with either pure Helium or mixture of Helium and Neon, and a short pulse of 850 J, 10 ps generated broadband protons for point-projection radiography. Simultaneous spatially resolved soft-x-ray spectroscopy provided shock velocity, particle velocity and thermal emission measurements, constraining density and temperature for the field generation. The data and modeling indicate that a multi-KeV potential was present at the shock front where a strong electron pressure gradient existed. This work was performed under DOE contract DE-AC52-07NA27344 with support from OFES Early Career program and LLNL LDRD program.

  14. On a low intensity 241Am Compton spectrometer for measurement of electron momentum density

    Indian Academy of Sciences (India)

    B L Ahuja; N L Heda

    2007-05-01

    In this paper, a new design and construction of a low intensity (100 mCi) 241Am -ray Compton spectrometer is presented. The planar spectrometer is based on a small disc source with the shortest geometry. Measurement of the momentum density of polycrystalline Al is used to evaluate the performance of the new design. The measured profile is in good agreement with the existing theoretical data and our density functional calculations.

  15. Flux Loop Measurements of the Magnetic Flux Density in the CMS Magnet Yoke

    CERN Document Server

    Klyukhin, V I; Ball, A.; Curé, B.; Gaddi, A.; Gerwig, H.; Mulders, M.; Hervé, A.; Loveless, R.

    2016-01-01

    The Compact Muon Solenoid (CMS) is a general purpose detector, designed to run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its distinctive features include a 4 T superconducting solenoid with 6-m-diameter by 12.5-m-length free bore, enclosed inside a 10,000-ton return yoke made of construction steel. The return yoke consists of five dodecagonal three-layered barrel wheels and four end-cap disks at each end comprised of steel blocks up to 620 mm thick, which serve as the absorber plates of the muon detection system. To measure the field in and around the steel, a system of 22 flux loops and 82 3-D Hall sensors is installed on the return yoke blocks. A TOSCA 3-D model of the CMS magnet is developed to describe the magnetic field everywhere outside the tracking volume measured with the field-mapping machine. The first attempt is made to measure the magnetic flux density in the steel blocks of the CMS magnet yoke using the standard magnet discharge with the current ramp down speed of 1.5 A/...

  16. Development of a Lithium Beam Probe and Measurement of Density Pedestal in JT-60U

    Science.gov (United States)

    Kojima, Atsushi; Kamiya, Kensaku; Fujita, Takaaki; Kubo, Hirotaka; Iguchi, Harukazu; Oyama, Naoyuki; Suzuki, Takahiro; Kamada, Yutaka; JT-60 Team

    A lithium beam probe (LiBP) has been developed for the measurement of electron density profiles with highly spatial and temporal resolutions in JT-60U. Using an electron beam heating ion source with a capability of 10 mA extraction, a 5.5 mA beam has been injected to the plasmas. It corresponds to the equivalent neutral beam current of 2 mA. A spectrum width of the beam emission has been small enough to separate Zeeman splitting. By use of the LiBP, time evolutions of pedestal density profiles during type I and grassy edge localized modes (ELMs) have been obtained for the first time. After a type I ELM crash, the drop of the line-integrated density measured by an interferometer delays by 2 ms later than that of the pedestal density. Comparing the line-integrated density to the line integration of the edge density profile measured by the LiBP, it is found that the recovery from the type I ELM crash is correlated with the reduction of core plasma density. As for grassy ELMs, grassy ELMs have smaller density crashes than that of type I ELMs, which is mainly derived from the narrower ELM affected area.

  17. Measurement of hard tissue density of head phantom based on the HU by using CBCT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Moon Sun; Kang, Dong Wan; Kim, Jae Duk [School of Dentistry, Chosun University, Gwangju (Korea, Republic of)

    2009-09-15

    The purpose of this study was to determine a conversion coefficient for Hounsfield Units(HU) to material density (g cm{sup -3}) obtained from cone-beam computed tomography (CBMercuRay{sup TM}) data and to measure the hard tissue density based on the Hounsfield scale on dental head phantom. CT Scanner Phantom (AAPM) equipped with CT Number Insert consists of five cylindrical pins of materials with different densities and teflon ring was scanned by using the CBMercuRay{sup TM} (Hitachi, Tokyo, Japan) volume scanner. The raw data were converted into DICOM format and the HU of different areas of CT number insert measured by using CBWorks{sup TM}. Linear regression analysis and Student t-test were performed statistically. There was no significant difference (P>0.54) between real densities and measured densities. A linear regression was performed using the density, {rho} (g cm{sup -3}), as the dependent variable in terms of the HU (H). The regression equation obtained was {rho}=0.00072 H-0.01588 with an R2 value of 0.9968. Density values based on the Hounsfield scale was 1697.1 {+-} 24.9 HU in cortical bone, 526.5 {+-} 44.4 HU in trabecular bone, 2639.1 {+-} 48.7 HU in enamel, 1246.1 {+-} 39.4 HU in dentin of dental head phantom. CBCT provides an effective option for determination of material density expressed as Hounsfield Units.

  18. Density measurement of thin layers by electron energy loss spectroscopy (EELS).

    Science.gov (United States)

    Thomas, Jürgen; Ramm, Jürgen; Gemming, Thomas

    2013-07-01

    A method to measure the density of thin layers is presented which utilizes electron energy loss spectroscopy (EELS) techniques within a transmission electron microscope. The method is based on the acquisition of energy filtered images in the low loss region as well as of an element distribution map using core loss edges. After correction of multiple inelastic scattering effects, the intensity of the element distribution map is proportional to density and thickness. The dependence of the intensities of images with low energy loss electrons on the density is different from that. This difference allows the calculation of the relative density pixel by pixel and to determine lateral density gradients or fluctuations in thin films without relying on a constant specimen thickness. The method is demonstrated at thin carbon layers produced with density gradients.

  19. DC Magnetics Measurement System Design

    Science.gov (United States)

    Mastny, Timothy

    2012-01-01

    This report will detail the updates to the magnetics measurement system design and testing procedures that are required for performing static (DC) magnetics testing of future flight hardware. An older magnetics testing system had to be integrated with new procedures and hardware to meet the demands of future testing programs and accommodate an upcoming magnetics tests. The next test will be for the Geostationary Operational Environmental Satellite R-Series (GOES-R), which will verify that the SAFT Battery component meets its specifications for magnetic cleanliness. The satellite is scheduled to launch in 2015 with magnetics testing to be completed on the battery in November 2012.

  20. Development and Application of a Wireless Sensor for Space Charge Density Measurement in an Ultra-High-Voltage, Direct-Current Environment.

    Science.gov (United States)

    Xin, Encheng; Ju, Yong; Yuan, Haiwen

    2016-10-20

    A space charge density wireless measurement system based on the idea of distributed measurement is proposed for collecting and monitoring the space charge density in an ultra-high-voltage direct-current (UHVDC) environment. The proposed system architecture is composed of a number of wireless nodes connected with space charge density sensors and a base station. The space charge density sensor based on atmospheric ion counter method is elaborated and developed, and the ARM microprocessor and Zigbee radio frequency module are applied. The wireless network communication quality and the relationship between energy consumption and transmission distance in the complicated electromagnetic environment is tested. Based on the experimental results, the proposed measurement system demonstrates that it can adapt to the complex electromagnetic environment under the UHVDC transmission lines and can accurately measure the space charge density.

  1. X-ray radiographic technique for measuring density uniformity of silica aerogel

    CERN Document Server

    Tabata, Makoto; Adachi, Ichiro; Morita, Takeshi; Nishikawa, Keiko; 10.1016/j.nima.2012.09.001

    2012-01-01

    This paper proposes a new X-ray radiographic technique for measuring density uniformity of silica aerogels used as radiator in proximity-focusing ring-imaging Cherenkov detectors. To obtain high performance in a large-area detector, a key characteristic of radiator is the density (i.e. refractive index) uniformity of an individual aerogel monolith. At a refractive index of n = 1.05, our requirement for the refractive index uniformity in the transverse plane direction of an aerogel tile is |\\delta (n - 1)/(n - 1)| < 4% in a focusing dual layer radiator (with different refractive indices) scheme. We applied the radiographic technique to evaluate the density uniformity of our original aerogels from a trial production and that of Panasonic products (SP-50) as a reference, and to confirm they have sufficient density uniformity within \\pm 1% along the transverse plane direction. The measurement results show that the proposed technique can quantitatively estimate the density uniformity of aerogels.

  2. Automated determination of electron density from electric field measurements on the Van Allen Probes spacecraft

    Science.gov (United States)

    Zhelavskaya, Irina; Kurth, William; Spasojevic, Maria; Shprits, Yuri

    2016-07-01

    We present the Neural-network-based Upper-hybrid Resonance Determination (NURD) algorithm for automatic inference of the electron number density from plasma wave measurements made onboard NASA's Van Allen Probes mission. A feedforward neural network is developed to determine the upper hybrid resonance frequency, f_{uhr}, from electric field measurements, which is then used to calculate the electron number density. In previous missions, the plasma resonance bands were manually identified, and there have been few attempts to do robust, routine automated detections. We describe the design and implementation of the algorithm and perform an initial analysis of the resulting electron number density distribution obtained by applying NURD to 2.5 years of data collected with the EMFISIS instrumentation suite of the Van Allen Probes mission. Densities obtained by NURD are compared to those obtained by another recently developed automated technique and also to an existing empirical plasmasphere and trough density model.

  3. Brief communication: Improved measurement of ice layer density in seasonal snowpacks

    Science.gov (United States)

    Watts, Tom; Rutter, Nick; Toose, Peter; Derksen, Chris; Sandells, Melody; Woodward, John

    2016-09-01

    The microstructure and density of ice layers in snowpacks is poorly quantified. Here we present a new field method for measuring the density of ice layers caused by melt or rain-on-snow events. The method was used on 87 ice layer samples taken from natural and artificial ice layers in the Canadian Arctic and mid-latitudes. Mean measured ice layer density was 909 ± 28 kg m-3 with a standard deviation of 23 kg m-3, significantly higher than values typically used in the literature.

  4. Imaging polychromator for density measurements of polystyrene pellet cloud on the Large Helical Device

    Energy Technology Data Exchange (ETDEWEB)

    Sharov, I. A., E-mail: i.sharov@spbstu.ru; Sergeev, V. Yu.; Miroshnikov, I. V. [Saint-Petersburg State Polytechnical University, Saint-Petersburg (Russian Federation); Tamura, N.; Sudo, S. [National Institute for Fusion Science, Toki (Japan); Kuteev, B. V. [Russian Scientific Centre Kurchatov Institute, Moscow (Russian Federation)

    2015-04-15

    Experimental data on spatial distributions of a pellet cloud electron density are necessary for the development of many applications of pellet injection, namely, plasma fuelling, discharge control, and plasma diagnostics. An improved approach of electron density measurements inside the cloud of a polystyrene pellet ablating in hot plasma of the large helical device is described. Density values of (1-30) × 10{sup 16} cm{sup −3} depending on the background plasma parameters and distance from the solid pellet were measured.

  5. Measuring the mass, density, and size of particles and cells using a suspended microchannel resonator

    Science.gov (United States)

    Godin, Michel; Bryan, Andrea K.; Burg, Thomas P.; Babcock, Ken; Manalis, Scott R.

    2007-09-01

    We demonstrate the measurement of mass, density, and size of cells and nanoparticles using suspended microchannel resonators. The masses of individual particles are quantified as transient frequency shifts, while the particles transit a microfluidic channel embedded in the resonating cantilever. Mass histograms resulting from these data reveal the distribution of a population of heterogeneously sized particles. Particle density is inferred from measurements made in different carrier fluids since the frequency shift for a particle is proportional to the mass difference relative to the displaced solution. We have characterized the density of polystyrene particles, Escherichia coli, and human red blood cells with a resolution down to 10-4g/cm3.

  6. Does the prediction of breast cancer improve using a combination of mammographic density measures compared to individual measures alone?

    Science.gov (United States)

    Wong Sik Hee, Joseph Ryan; Harkness, Elaine F.; Gadde, Soujanya; Lim, Yit Y.; Maxwell, Anthony J.; Evans, D. Gareth; Howell, Anthony; Astley, Susan M.

    2017-03-01

    High mammographic density is associated with an increased risk of breast cancer, however whether the association is stronger when there is agreement across measures is unclear. This study investigates whether a combination of density measures is a better predictor of breast cancer risk than individual methods alone. Women recruited to the Predicting Risk of Cancer At Screening (PROCAS) study and with mammographic density assessed using three different methods were included (n=33,304). Density was assessed visually using Visual Analogue Scales (VAS) and by two fully automated methods, Quantra and Volpara. Percentage breast density was divided into (high, medium and low) and combinations of measures were used to further categorise individuals (e.g. `all high'). A total of 667 breast cancers were identified and logistic regression was used to determine the relationship between breast density and breast cancer risk. In total, 44% of individuals were in the same tertile for all three measures, 8.6% were in non-adjacent (high and low) or mixed categories (high, medium and low). For individual methods the strongest association with breast cancer risk was for medium and high tertiles of VAS with odds ratios (OR) adjusted for age and BMI of 1.63 (95% CI 1.31-2.03) and 2.33 (1.87-2.90) respectively. For the combination of density methods the strongest association was for `all high' (OR 2.42, 1.77-3.31) followed by "two high" (OR 1.90, 1.35-3.31) and "two medium" (OR 1.88, 1.40-2.52). Combining density measures did not affect the magnitude of risk compared to using individual methods.

  7. Single x-ray transmission system for bone mineral density determination

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez-Mendoza, Daniel; Vargas-Vazquez, Damian [Division de Investigacion y Posgrado, Facultad de Ingenieria, Universidad Autonoma de Queretaro, Cerro de las Campanas s/n., C.P. 76010, Queretaro, Qro. (Mexico); Espinosa-Arbelaez, Diego G. [Posgrado en Ciencia e Ingenieria en Materiales, Instituto de Investigaciones en Materiales, Universidad Nacional Autonoma de Mexico, Av. Universidad 3000, C.P. 04510, Coyoacan, Mexico D.F. (Mexico); Departamento de Nanotecnologia, Centro de Fisica Aplicada y Tecnologia Avanzada, Universidad Nacional Autonoma de Mexico, Campus Juriquilla, Boulevard Juriquilla 3001, C.P. 76230, A.P. 1-1010, Juriquilla, Qro. (Mexico); Giraldo-Betancur, Astrid L. [Centro de Investigacion y de Estudios Avanzados del Instituto Politecnico Nacional, Libramiento Norponiente 2000, C.P. 76230, Fracc. Real de Juriquilla, Qro. (Mexico); Hernandez-Urbiola, Margarita I. [Posgrado en Investigaciones Biomedicas, Universidad Nacional Autonoma de Mexico, Campus Juriquilla, Boulevard Juriquilla 3001, C.P. 76230, A.P. 1-1010, Juriquilla, Qro. (Mexico); Departamento de Nanotecnologia, Centro de Fisica Aplicada y Tecnologia Avanzada, Universidad Nacional Autonoma de Mexico, Campus Juriquilla, Boulevard Juriquilla 3001, C.P. 76230, A.P. 1-1010, Juriquilla, Qro. (Mexico); Rodriguez-Garcia, Mario E. [Departamento de Nanotecnologia, Centro de Fisica Aplicada y Tecnologia Avanzada, Universidad Nacional Autonoma de Mexico, Campus Juriquilla, Boulevard Juriquilla 3001, C.P. 76230, A.P. 1-1010, Juriquilla, Qro. (Mexico)

    2011-12-15

    Bones are the support of the body. They are composed of many inorganic compounds and other organic materials that all together can be used to determine the mineral density of the bones. The bone mineral density is a measure index that is widely used as an indicator of the health of the bone. A typical manner to evaluate the quality of the bone is a densitometry study; a dual x-ray absorptiometry system based study that has been widely used to assess the mineral density of some animals' bones. However, despite the success stories of utilizing these systems in many different applications, it is a very expensive method that requires frequent calibration processes to work properly. Moreover, its usage in small species applications (e.g., rodents) has not been quite demonstrated yet. Following this argument, it is suggested that there is a need for an instrument that would perform such a task in a more reliable and economical manner. Therefore, in this paper we explore the possibility to develop a new, affordable, and reliable single x-ray absorptiometry system. The method consists of utilizing a single x-ray source, an x-ray image sensor, and a computer platform that all together, as a whole, will allow us to calculate the mineral density of the bone. Utilizing an x-ray transmission theory modified through a version of the Lambert-Beer law equation, a law that expresses the relationship among the energy absorbed, the thickness, and the absorption coefficient of the sample at the x-rays wavelength to calculate the mineral density of the bone can be advantageous. Having determined the parameter equation that defines the ratio of the pixels in radiographies and the bone mineral density [measured in mass per unit of area (g/cm{sup 2})], we demonstrated the utility of our novel methodology by calculating the mineral density of Wistar rats' femur bones.

  8. Wireless sap flow measurement system

    Science.gov (United States)

    Kuo, C.; Davis, T. W.; Tseng, C.; Cheng, C.; Liang, X.; Yu, P.

    2010-12-01

    This study exhibits a measurement system for wireless sensor networks to measure sap flow in multiple locations simultaneously. Transpiration is a major component of the land-surface system because it is indicative of the water movement between the soil and the air. Sap flow can be used to approximate transpiration. In forests, transpiration cannot be represented by the sap flow from a single tree. Multi-location sap flow measurements are required to show the heterogeneity caused by different trees or soil conditions. Traditional multi-location measurements require manpower and capital for data collection and instrument maintenance. Fortunately, multi-location measurements can be achieved by using the new technology of wireless sensor networks. With multi-hop communication protocol, data can be forwarded to the base station via multiple sensor nodes. This communication protocol can provide reliable data collection with the least power consumption. This study encountered two major problems. The first problem was signal amplification. The Crossbow IRIS mote was selected as the sensor node that receives the temperature data of the sap flow probe (thermocouple) through a MDA300 data acquisition board. However, the wireless sensor node could not directly receive any data from the thermocouples since the least significant bit value of the MDA300, 0.6 mV, is much higher than the voltage signal generated. Thus, the signal from the thermocouple must be amplified to exceed this threshold. The second problem is power management. A specific heat differential is required for the thermal dissipation method of measuring sap flow. Thus, an adjustable DC power supply is necessary for calibrating the heater's temperature settings. A circuit was designed to combine the signal amplifier and power regulator. The regulator has been designed to also provide power to the IRIS mote to extend battery life. This design enables wireless sap flow measurements in the forest. With the

  9. Feature selection using feature dissimilarity measure and density-based clustering: Application to biological data

    Indian Academy of Sciences (India)

    Debarka Sengupta; Indranil Aich; Sanghamitra Bandyopadhyay

    2015-10-01

    Reduction of dimensionality has emerged as a routine process in modelling complex biological systems. A large number of feature selection techniques have been reported in the literature to improve model performance in terms of accuracy and speed. In the present article an unsupervised feature selection technique is proposed, using maximum information compression index as the dissimilarity measure and the well-known density-based cluster identification technique DBSCAN for identifying the largest natural group of dissimilar features. The algorithm is fast and less sensitive to the user-supplied parameters. Moreover, the method automatically determines the required number of features and identifies them. We used the proposed method for reducing dimensionality of a number of benchmark data sets of varying sizes. Its performance was also extensively compared with some other well-known feature selection methods.

  10. Spatially resolved density and ionization measurements of shocked foams using x-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, M. J.; Keiter, P. A.; Montgomery, D. S.; Scott, H. A.; Biener, M. M.; Fein, J. R.; Fournier, K. B.; Gamboa, E. J.; Kemp, G. E.; Klein, S. R.; Kuranz, C. C.; LeFevre, H. J.; Manuel, M. J. -E.; Wan, W. C.; Drake, R. P.

    2016-09-28

    We present experiments at the Trident laser facility demonstrating the use of x-ray fluorescence (XRF) to simultaneously measure density, ionization state populations, and electron temperature in shocked foams. An imaging x-ray spectrometer obtained spatially resolved measurements of Ti K-α emission. Density profiles were measured from K-α intensity. Ti ionization state distributions and electron temperatures were inferred by fitting K-α spectra to spectra from CRETIN simulations. This work shows that XRF provides a powerful tool to complement other diagnostics to make equation of state measurements of shocked materials containing a suitable tracer element.

  11. Linearized Controller Design for the Output Probability Density Functions of Non-Gaussian Stochastic Systems

    Institute of Scientific and Technical Information of China (English)

    Pousga Kabore; Husam Baki; Hong Yue; Hong Wang

    2005-01-01

    This paper presents a linearized approach for the controller design of the shape of output probability density functions for general stochastic systems. A square root approximation to an output probability density function is realized by a set of B-spline functions. This generally produces a nonlinear state space model for the weights of the B-spline approximation. A linearized model is therefore obtained and embedded into a performance function that measures the tracking error of the output probability density function with respect to a given distribution. By using this performance function as a Lyapunov function for the closed loop system, a feedback control input has been obtained which guarantees closed loop stability and realizes perfect tracking. The algorithm described in this paper has been tested on a simulated example and desired results have been achieved.

  12. A new measurement method of magnetic flux density using magnetorheological fluid characteristics and a variable resistor circuit

    Science.gov (United States)

    Kim, Hwan-Choong; Han, Chulhee; Kim, Pyunghwa; Choi, Seung-Bok

    2015-08-01

    This work proposes a new approach with which to measure the magnetic flux density using the characteristics of magnetorheological fluid (MRF) that is integrated with a variable resistor. For convenience, it is called a magnetorheological fluid variable resistor (MRF-VR) system in this study. The mechanism of the MRF-VR is based on the interaction between ferromagnetic iron particles of the MRF due to an external magnetic field, which causes its electrical resistance to be field dependent. Using this salient principle, the proposed MRF-VR system is constructed with electrodes and MRF, and its performance is demonstrated by evaluating its electrical resistive characteristics such as dimensional influence, response time, hysteresis and frequency response. After evaluating the performance characteristics, a feedback control system with a proportional-integral-derivative (PID) controller is established, and resistance-trajectory control experiments are carried out. Based on this MRF-VR system, a magnetic field-sensing system is constructed using a Wheatstone bridge circuit, and a polynomial model for calculating the magnetic flux density is formulated from the measured voltage. Finally, the accuracy and effectiveness of the proposed sensing system associated with the empirical polynomial model is successfully verified by comparing the calculated values of magnetic flux density with those measured by a commercial tesla meter.

  13. Stochastic measurements and systems implications

    Science.gov (United States)

    Collins, J. L.; Greene, R. R.

    1985-06-01

    The U.S. Navy is defining the baseline performance of the current SSN ASW suite in the Arctic operating environment. This suite includes the AN/BQQ-5 sonar suit (including the Towed Array, the sphere and other sensor and processor sub-systems), communications subsystems and weapon systems (Mk 48 and ADCAP). An effective acoustic measurement program in the Arctic must support the evaluation of how well the different subsystems are able to carry out their assigned functions. Unique aspects of the operating environment in the Arctic include unusual noise properties, unusual transmission effects and an unusual sea surface. This report addresses those acoustic transmission effects which affect system performance due to fluctuations or spreads in the acoustic field space, angle time and frequency.

  14. A system verification platform for high-density epiretinal prostheses.

    Science.gov (United States)

    Chen, Kuanfu; Lo, Yi-Kai; Yang, Zhi; Weiland, James D; Humayun, Mark S; Liu, Wentai

    2013-06-01

    Retinal prostheses have restored light perception to people worldwide who have poor or no vision as a consequence of retinal degeneration. To advance the quality of visual stimulation for retinal implant recipients, a higher number of stimulation channels is expected in the next generation retinal prostheses, which poses a great challenge to system design and verification. This paper presents a system verification platform dedicated to the development of retinal prostheses. The system includes primary processing, dual-band power and data telemetry, a high-density stimulator array, and two methods for output verification. End-to-end system validation and individual functional block characterization can be achieved with this platform through visual inspection and software analysis. Custom-built software running on the computers also provides a good way for testing new features before they are realized by the ICs. Real-time visual feedbacks through the video displays make it easy to monitor and debug the system. The characterization of the wireless telemetry and the demonstration of the visual display are reported in this paper using a 256-channel retinal prosthetic IC as an example.

  15. Principles for microwave moisture and density measurement in grain and seed.

    Science.gov (United States)

    Nelson, Stuart O; Trabelsi, Samir

    2004-01-01

    The importance of cereal grain moisture content in determining time of harvest and in preserving grain quality is described. Techniques for moisture measurement, including electronic moisture meters, are also discussed briefly, and the need for better moisture sensing techniques for modern agricultural on-line moisture monitoring is described. Principles of microwave free-space measurements involving attenuation and phase-shift determination are explained, and density-independent functions of the grain permittivity are presented that permit reliable moisture sensing applicable to moving grain in which bulk density variation occurs. Three different approaches are discussed for determining moisture content and bulk density of grain from microwave measurement of the dielectric properties. A new moisture calibration function, based on complex-plane plots of dielectric constant and loss factor, each divided by bulk density, is described, which promises a universal calibration for different types of grain and seed. This important advantage should encourage commercial development for practical use.

  16. Summer sudden Na number density enhancements measured with the ALOMAR Weber Na Lidar

    Directory of Open Access Journals (Sweden)

    D. Heinrich

    2008-05-01

    Full Text Available We present summer Na-densities and atmospheric temperatures measured 80 to 110 km above the Arctic Lidar Observatory for Middle Atmosphere Research (ALOMAR. The Weber Na Lidar is part of ALOMAR, located at 69° N in Norway, 150 km north of the Arctic Circle. The sun does not set here during the summer months, and measurements require a narrowband Faraday Anomalous Dispersion Optical Filter (FADOF.

    We discuss an observed sudden enhancement in the Na number density around 22:00 UT on 1 to 2 June 2006. We compare this observation with previous summer measurements and find a frequent appearance of Na number density enhancements near local midnight. We describe the time of appearance, the altitude distribution, the duration and the strength of these enhancements and compare them to winter observations. We investigate possible formation mechanisms and, as others before, we find a strong link between these Na number density enhancements and sporadic E layers.

  17. Development of density measurement method of negative ion in plasmas using laser Thomson scattering

    Science.gov (United States)

    Yamagata, Yukihiko; Saiho, Hiroatsu; Uchino, Kiichiro; Muraoka, Katsunori

    2004-09-01

    Measurements of negative ion density in plasmas have been an important subject for many years. We have proposed a new method to measure the negative ion density in plasmas using laser Thomson scattering (LTS), and successfully measured O^- ion density in an radio frequency inductively coupled plasma [1]. In order to ensure the reliability of this technique and to estimate the accuracy, we have measured O^- ion density in the same experimental conditions using the second (SHG) and third harmonics (THG) of a Nd:YAG laser as different laser sources. The LTS spectra measured at pure argon plasma (500 W, 20 mTorr) fitted in a straight line well in both SHG and THG cases. As for the plasma at 500 W in 20 mTorr with Ar/O_2=95%/5%, a clear bump in LTS spectra, which is caused by photo-detached electrons, was observed below 0.9 eV for the SHG case and 2 eV for the case, as predicted by a difference between the electron affinity of O^- ion and the laser photon energy. The electron temperatures, the electron densities and the O^- ion densities, which were obtained from the spectral shape and intensity of both LTS spectra, were in agreement each other within an experimental error. [1] M. Noguchi, K. Ariga, T. Hirao, P. Suanpoot, Y. Yamagata, K. Uchino, K. Muraoka, Plasma Sources Sci. Technol., 11 (2002) 57.

  18. Current density imaging using directly measured harmonic Bz data in MREIT.

    Science.gov (United States)

    Park, Chunjae; Kwon, Oh In

    2013-01-01

    Magnetic resonance electrical impedance tomography (MREIT) measures magnetic flux density signals through the use of a magnetic resonance imaging (MRI) in order to visualize the internal conductivity and/or current density. Understanding the reconstruction procedure for the internal current density, we directly measure the second derivative of Bz data from the measured k-space data, from which we can avoid a tedious phase unwrapping to obtain the phase signal of Bz . We determine optimal weighting factors to combine the derivatives of magnetic flux density data, [Symbol: see text](2) Bz , measured using the multi-echo train. The proposed method reconstructs the internal current density using the relationships between the induced internal current and the measured [Symbol: see text](2) Bz data. Results from a phantom experiment demonstrate that the proposed method reduces the scanning time and provides the internal current density, while suppressing the background field inhomogeneity. To implement the real experiment, we use a phantom with a saline solution including a balloon, which excludes other artifacts by any concentration gradient in the phantom.

  19. The decay of excited He from Stochastic Density-Functional Theory: a quantum measurement theory interpretation

    OpenAIRE

    2007-01-01

    Recently, time-dependent current-density functional theory has been extended to include the dynamical interaction of quantum systems with external environments [Phys. Rev. Lett. {\\bf 98}, 226403 (2007)]. Here we show that such a theory allows us to study a fundamentally important class of phenomena previously inaccessible by standard density-functional methods: the decay of excited systems. As an example we study the decay of an ensemble of excited He atoms, and discuss these results in the c...

  20. Moment-independent importance measure of basic random variable and its probability density evolution solution

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    To analyze the effect of basic variable on failure probability in reliability analysis,a moment-independent importance measure of the basic random variable is proposed,and its properties are analyzed and verified.Based on this work,the importance measure of the basic variable on the failure probability is compared with that on the distribution density of the response.By use of the probability density evolution method,a solution is established to solve two importance measures,which can efficiently avoid the difficulty in solving the importance measures.Some numerical examples and engineering examples are used to demonstrate the proposed importance measure on the failure probability and that on the distribution density of the response.The results show that the proposed importance measure can effectively describe the effect of the basic variable on the failure probability from the distribution density of the basic variable.Additionally,the results show that the established solution on the probability density evolution is efficient for the importance measures.

  1. Retrieval of tropospheric column densities of NO2 from combined SCIAMACHY nadir/limb measurements

    Directory of Open Access Journals (Sweden)

    T. Wagner

    2009-11-01

    Full Text Available The SCIAMACHY instrument onboard the ESA satellite ENVISAT allows the retrieval of column densities of various trace gases, among them NO2. As only instrument of its kind, SCIAMACHY measures in an alternating limb/nadir mode. The limb measurements allow a direct determination of stratospheric column densities, which are needed to extract tropospheric from the total column density measurements performed in (quasi simultaneous nadir geometry. Here we discuss the potential and limitations of SCIAMACHY limb measurements for estimating stratospheric column densities of NO2 in comparison to a simple reference sector method, and the consequences for the resulting tropospheric column densities. A direct, absolute limb correction scheme improves spatial patterns of tropospheric NO2 column densities at high latitudes compared to the simple reference sector method. However, it results in artificial zonal stripes at low latitudes. Thus, also a relative limb correction scheme was defined, which turned out to successfully reduce stratospheric artefacts in the resulting tropospheric data product without introducing new ones. This relative limb correction scheme is rather simple, robust, and, in essence, based on measurements alone. The effect of the different stratospheric estimation schemes on tropospheric column densities is discussed with respect to zonal and temporal dependencies. In addition, error quantities are defined from the nadir/limb measurements which indicate remaining systematic errors as function of latitude and day. Our new suggested stratospheric estimation scheme, the relative limb correction, improves monthly mean tropospheric slant column densities significantly, e.g. from −1×1015 molec/cm2 (using a simple reference sector method to ≈0 in the Atlantic ocean, and from +1×1015 molec/cm2 to ≈0 over Siberia, at 50° N in January.

  2. Measurement of Supersonic Jet Noise with Optical Wave Microphone System

    Institute of Scientific and Technical Information of China (English)

    Masataka KOSAKA; Kunisato SETO; MD. Tawhidul Islam KHAN; Yoichi NAKAZONO

    2005-01-01

    An optical wave microphone system is a new technique of sound measurement. This technique has been developed as a new plasma diagnostic technique to measure electron density fluctuations in the nuclear fusion research. Because the sound wave is a pressure or a density fluctuation, it is possible for this technique to measure the sound wave, too. The acoustical characteristics of the optical wave microphone system were examined by using a speaker as a first step. Next, feasibility of this device to measure jet noise was examined. It was found that the optical wave microphone system could measure the jet noise as well as a sound from speaker.Hence the optical wave microphone system can be considered one of the devices equivalent to condenser microphone. Because of these reason, this device is very convenient to scan the acoustic filed through jet flow from the inside to the out side and more preferable for not disturbing the observation field.

  3. Algorithms for density and composition-discrimination imaging for fourth-generation CT systems.

    Science.gov (United States)

    Busono, P; Hussein, E M

    1999-06-01

    This paper shows that if the off-beam idle detectors in the detection ring of a fourth-generation x-ray computed tomography (CT) system are used to measure the scattered radiation, it is numerically feasible to reconstruct electron-density images to supplement the conventional attenuation-coefficient images of transmitted radiation. It is also shown that by combining these two images, composition changes can be detected with the aid of an effective-atomic-number indicator. The required image-reconstruction algorithms are developed and tested against Monte Carlo simulated measurements, for a variety of phantom configurations. In spite of the relatively poor statistical quality of scattering measurements, it is demonstrated that electron-density images of reasonable quality can be obtained. In addition, it is shown that composition discrimination is possible for materials of effective atomic number greater than five, in the photon energy range of a typical medical x-ray CT system operating at 102 kVp. The obtained supplementary electron-density and composition images can be useful in radiotherapy planning and for studying tumour histology, as well as in industrial and security applications where identification of materials based on density and composition is important.

  4. SQUID-based measuring systems

    Indian Academy of Sciences (India)

    M P Janawadkar; R Baskaran; R Nagendran; K Gireesan; N Harishkumar; Rita Saha; L S Vaidhyanathan; J Jayapandian; Y Hariharan; T S Radhakrishnan

    2002-05-01

    A program has been developed and initiated at the Indira Gandhi Centre for Atomic Research (IGCAR) for the utilization of SQUID sensors in various application areas. DC SQUID sensors based on Nb–AlO–Nb Josephson junctions have been designed and developed inhouse along with associated flux-locked loop (FLL) electronics. A compact low field SQUID magnetometer insertible in a liquid helium storage dewar has also been developed inhouse and is in use. Efforts to build a high field SQUID magnetometer, SQUID-DAC system, are in progress. A planar gradiometric DC SQUID sensor for non-destructive evaluation (NDE) application to be used in relatively unshielded environment has been designed and developed. An easily portable NDE cryostat with a small lift-off distance, to be used in external locations has been designed and tested. The magnetic field produced by a given two-dimensional current density distribution is inverted using the Fourier transform technique.

  5. High density collinear holographic data storage system (Conference Presentation)

    Science.gov (United States)

    Tan, Xiaodi; Horimai, Hideyoshi; Arai, Ryo; Ikeda, Junichi; Inoue, Mitsuteru; Lin, Xiao; Xu, Ke; Liu, Jinpeng; Huang, Yong

    2016-09-01

    Collinear holography has been good candidate for a volumetric recording technology of holographic data storage system (HDSS), because of there are not only large storage capacities, high transfer rates, but also the unique configuration, in which the information and reference beams are modulated co-axially by the same spatial light modulator, as a new read/write method for HDSS are very promising. The optical pickup can be designed as small as DVDs, and can be placed on one side of the recording media (disc). In the disc structure, the preformatted reflective layer is used for the focus/tracking servo and reading address information, and a dichroic mirror layer is used for detecting holographic recording information without interfering with the preformatted information. A 2-dimensional digital page data format is used and the shift-multiplexing method is employed to increase recording density. As servo technologies are being introduced to control the objective lens to be maintained precisely to the disc in the recording and reconstructing process, a vibration isolator is no longer necessary. In this paper, we introduced the principle of the collinear holography and its media structure of disc. Some results of experimental and theoretical studies suggest that it is a very effective method. We also discussed some methods to increase the recording density and data transfer rates of collinear holography using phase modulated page data format.

  6. On the Study of Vehicle Density in Intelligent Transportation Systems

    Directory of Open Access Journals (Sweden)

    Julio A. Sanguesa

    2016-01-01

    Full Text Available Vehicular ad hoc networks (VANETs are wireless communication networks which support cooperative driving among vehicles on the road. The specific characteristics of VANETs favor the development of attractive and challenging services and applications which rely on message exchanging among vehicles. These communication capabilities depend directly on the existence of nearby vehicles able to exchange information. Therefore, higher vehicle densities favor the communication among vehicles. However, vehicular communications are also strongly affected by the topology of the map (i.e., wireless signal could be attenuated due to the distance between the sender and receiver, and obstacles usually block signal transmission. In this paper, we study the influence of the roadmap topology and the number of vehicles when accounting for the vehicular communications capabilities, especially in urban scenarios. Additionally, we consider the use of two parameters: the SJ Ratio (SJR and the Total Distance (TD, as the topology-related factors that better correlate with communications performance. Finally, we propose the use of a new density metric based on the number of vehicles, the complexity of the roadmap, and its maximum capacity. Hence, researchers will be able to accurately characterize the different urban scenarios and better validate their proposals related to cooperative Intelligent Transportation Systems based on vehicular communications.

  7. Bayesian Semiparametric Density Deconvolution in the Presence of Conditionally Heteroscedastic Measurement Errors

    KAUST Repository

    Sarkar, Abhra

    2014-10-02

    We consider the problem of estimating the density of a random variable when precise measurements on the variable are not available, but replicated proxies contaminated with measurement error are available for sufficiently many subjects. Under the assumption of additive measurement errors this reduces to a problem of deconvolution of densities. Deconvolution methods often make restrictive and unrealistic assumptions about the density of interest and the distribution of measurement errors, e.g., normality and homoscedasticity and thus independence from the variable of interest. This article relaxes these assumptions and introduces novel Bayesian semiparametric methodology based on Dirichlet process mixture models for robust deconvolution of densities in the presence of conditionally heteroscedastic measurement errors. In particular, the models can adapt to asymmetry, heavy tails and multimodality. In simulation experiments, we show that our methods vastly outperform a recent Bayesian approach based on estimating the densities via mixtures of splines. We apply our methods to data from nutritional epidemiology. Even in the special case when the measurement errors are homoscedastic, our methodology is novel and dominates other methods that have been proposed previously. Additional simulation results, instructions on getting access to the data set and R programs implementing our methods are included as part of online supplemental materials.

  8. Evaluating outer segment length as a surrogate measure of peak foveal cone density.

    Science.gov (United States)

    Wilk, Melissa A; Wilk, Brandon M; Langlo, Christopher S; Cooper, Robert F; Carroll, Joseph

    2017-01-01

    Adaptive optics (AO) imaging tools enable direct visualization of the cone photoreceptor mosaic, which facilitates quantitative measurements such as cone density. However, in many individuals, low image quality or excessive eye movements precludes making such measures. As foveal cone specialization is associated with both increased density and outer segment (OS) elongation, we sought to examine whether OS length could be used as a surrogate measure of foveal cone density. The retinas of 43 subjects (23 normal and 20 albinism; aged 6-67years) were examined. Peak foveal cone density was measured using confocal adaptive optics scanning light ophthalmoscopy (AOSLO), and OS length was measured using optical coherence tomography (OCT) and longitudinal reflectivity profile-based approach. Peak cone density ranged from 29,200 to 214,000cones/mm(2) (111,700±46,300cones/mm(2)); OS length ranged from 26.3 to 54.5μm (40.5±7.7μm). Density was significantly correlated with OS length in albinism (pdensity as a function of OS length was created based on histology and optimized to fit the albinism data. The model includes triangular cone packing, a cylindrical OS with a fixed volume of 136.6μm(3), and a ratio of OS to inner segment width that increased linearly with increasing OS length (R(2)=0.72). Normal subjects showed no apparent relationship between cone density and OS length. In the absence of adequate AOSLO imagery, OS length may be used to estimate cone density in patients with albinism. Whether this relationship exists in other patient populations with foveal hypoplasia (e.g., premature birth, aniridia, isolated foveal hypoplasia) remains to be seen. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Two-resonance probe for measuring electron density in low-pressure plasmas

    Science.gov (United States)

    Kim, D. W.; You, S. J.; Kim, S. J.; Kim, J. H.; Oh, W. Y.

    2017-04-01

    A technique for measuring double-checked electron density using two types of microwave resonance is presented. Simultaneous measurement of the resonances (plasma and quarter-wavelength resonator resonances), which were used for the cutoff probe (CP) and hairpin probe (HP), was achieved by the proposed microwave resonance probe. The developed two-resonance probe (TRP) consists of parallel separated coaxial cables exposing the radiation and detection tips. The structure resembles that of the CP, except the gapped coaxial cables operate not only as a microwave feeder for the CP but also as a U- shaped quarter-wavelength resonator for the HP. By virtue of this structure, the microwave resonances that have typically been used for measuring the electron density for the CP and HP were clearly identified on the microwave transmission spectrum of the TRP. The two types of resonances were measured experimentally under various power and pressure conditions for the plasma. A three-dimensional full-wave simulation model for the TRP is also presented and used to investigate and reproduce the resonances. The electron densities inferred from the resonances were compared and showed good agreement. Quantitative differences between the densities were attributed to the effects of the sheath width and spatial density gradient on the resonances. This accessible technique of using the TRP to obtain double-checked electron densities may be useful for comparative study and provides complementary uses for the CP and HP.

  10. Molecular Rayleigh Scattering Techniques Developed for Measuring Gas Flow Velocity, Density, Temperature, and Turbulence

    Science.gov (United States)

    Mielke, Amy F.; Seasholtz, Richard G.; Elam, Kristie A.; Panda, Jayanta

    2005-01-01

    Nonintrusive optical point-wise measurement techniques utilizing the principles of molecular Rayleigh scattering have been developed at the NASA Glenn Research Center to obtain time-averaged information about gas velocity, density, temperature, and turbulence, or dynamic information about gas velocity and density in unseeded flows. These techniques enable measurements that are necessary for validating computational fluid dynamics (CFD) and computational aeroacoustic (CAA) codes. Dynamic measurements allow the calculation of power spectra for the various flow properties. This type of information is currently being used in jet noise studies, correlating sound pressure fluctuations with velocity and density fluctuations to determine noise sources in jets. These nonintrusive techniques are particularly useful in supersonic flows, where seeding the flow with particles is not an option, and where the environment is too harsh for hot-wire measurements.

  11. The effects of iterative reconstruction and kernel selection on quantitative computed tomography measures of lung density.

    Science.gov (United States)

    Rodriguez, Alfonso; Ranallo, Frank N; Judy, Philip F; Fain, Sean B

    2017-06-01

    To determine the effects of iterative reconstruction (IR) and high-frequency kernels on quantitative computed tomography (qCT) density measures at reduced X-ray dose. The COPDGene 2 Phantom (CTP 698, The Phantom Laboratory, Salem, NY) with four embedded lung mimicking foam densities (12lb, 20lb, and 4lb), as well as water, air, and acrylic reference inserts, was imaged using a GE 64 slice CT750 HD scanner in helical mode with four current-time products ranging from 12 to 100 mAs. The raw acquired data were reconstructed using standard (STD - low frequency) and Bone (high frequency) kernels with filtered back projection (FBP), 100% ASiR, and Veo reconstruction algorithms. The reference density inserts were manually segmented using Slicer3D (www.slicer.org), and the mean, standard deviation, and histograms of the segmented regions were generated using Fiji (http://fiji.sc/Fiji) for each reconstruction. Measurements of threshold values placed on the cumulative frequency distribution of voxels determined by these measured histograms at 5%, PD5phant , and 15%, PD15phant , (analogous to the relative area below -950 HU (RA-950) and percent density 15 (PD15) in human lung emphysema quantification, respectively), were also performed. The use of high-resolution kernels in conjunction with ASiR and Veo did not significantly affect the mean Hounsfield units (HU) of each of the density standards (density regions. The density histogram became more sharply peaked, and standard deviation was reduced for IR, directly effecting density thresholds, PD5phant and PD15phant, placed on the cumulative frequency distribution of each region in the phantom, which serve as analogs to RA-950 and PD15 typically used in lung density quantitation. The combination of high-frequency kernels (Bone) with ASiR mitigates this effect and preserves density measures derived from the image histogram. Moreover, previous studies have shown improved accuracy of qCT airway measures of wall thickness (WT) and

  12. Density-independent algorithm for sensing moisture content of sawdust based on reflection measurements

    Science.gov (United States)

    A density-independent algorithm for moisture content determination in sawdust, based on a one-port reflection measurement technique is proposed for the first time. Performance of this algorithm is demonstrated through measurement of the dielectric properties of sawdust with an open-ended haft-mode s...

  13. Particle image velocimetry measurements and numerical modeling of a saline density current

    CSIR Research Space (South Africa)

    Gerber, G

    2011-03-01

    Full Text Available Particle image velocimetry scalar measurements were carried out on the body of a stably stratified density current with an inlet Reynolds number of 2,300 and bulk Richardson number of 0.1. These measurements allowed the mass and momentum transport...

  14. Measuring the orbital angular momentum density for a superposition of Bessel beams

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2012-01-01

    Full Text Available To measure the Orbital Angular Momentum (OAM) density of superposition fields two steps are needed: generation and measurement. An azimuthally-varying phase (bounded by a ring-slit) placed in the spatial frequency domain produces a higher...

  15. Reaching Higher Densities for Laboratory White Dwarf Photospheres to Measure Spectroscopic Line Profiles

    CERN Document Server

    Falcon, Ross E; Gomez, T A; Schaeuble, M; Nagayama, T; Montgomery, M H; Winget, D E; Rochau, G A

    2016-01-01

    As part of our laboratory investigation of the theoretical line profiles used in white dwarf atmosphere models, we extend the electron-density ($n_{\\rm e}$) range measured by our experiments to higher densities (up to $n_{e}\\sim80\\times10^{16}$ cm$^{-3}$). Whereas inferred parameters using the hydrogen-$\\beta$ spectral line agree among different line-shape models for $n_{\\rm e}\\lesssim30\\times10^{16}$ cm$^{-3}$, we now see divergence between models. These are densities beyond the range previously benchmarked in the laboratory, meaning theoretical profiles in this regime have not been fully validated. Experimentally exploring these higher densities enables us to test and constrain different line-profile models, as the differences in their relative H-Balmer line shapes are more pronounced at such conditions. These experiments also aid in our study of occupation probabilities because we can measure these from relative line strengths.

  16. Far-infrared Michelson interferometer for tokamak electron density measurements using computer-generated reference fringes

    Energy Technology Data Exchange (ETDEWEB)

    Krug, P.A.; Stimson, P.A.; Falconer, I.S.

    1986-11-01

    A simple far-infrared interferometer which uses the 394 ..mu..m laser line from optically-pumped formic acid vapour to measure tokamak electron density is described. This interferometer is unusual in requiring only one detector and a single probing beam since reference fringes during the plasma shot are obtained by computer interpolation between the fringes observed immediately before and after the shot. Electron density has been measured with a phase resolution corresponding to + - 1/20 wavelength fringe shift, which is equivalent to a central density resolution of + - 0.1 x 10/sup 19/ m/sup -3/ for an assumed parabolic density distribution in a plasma of diameter of 0.2 m, and with a time resolution of 0.2 ms.

  17. Viscosity and Liquid Density of Asymmetric n-Alkane Mixtures: Measurement and Modelling

    DEFF Research Database (Denmark)

    Queimada, António J.; Marrucho, Isabel M.; Coutinho, João A.P.

    2005-01-01

    Viscosity and liquid density Measurements were performed, at atmospheric pressure. in pure and mixed n-decane. n-eicosane, n-docosane, and n-tetracosane from 293.15 K (or above the melting point) up to 343.15 K. The viscosity was determined with a rolling ball viscometer and liquid densities with...... of state and a corresponding states model recently proposed for surface tension, viscosity, vapor pressure, and liquid densities of the series of n-alkanes. Advantages and shortcoming of these models are discussed....

  18. Superfluid LDA (SLDA): Local Density Approximation for Systems with Superfluid Correlations

    CERN Document Server

    Bulgac, A; Bulgac, Aurel; Yu, Yongle

    2004-01-01

    We present a concise account of our development of the first genuine Local Density Approximation (LDA) to the Energy Density Functional (EDF) for fermionic systems with superfluid correlations, with a particular emphasis to nuclear systems.

  19. Intensity ratio measurements for density sensitive lines of highly charged Fe ions

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Safdar, E-mail: safdaruetian@gmail.com; Shimizu, Erina [Institute for Laser Science, The University of Electro-Communications (Japan); Sakaue, Hiroyuki A.; Kato, Daiji; Murakami, Izumi [National Institute for Fusion Science (Japan); Yamamoto, Norimasa [Chubu University (Japan); Hara, Hirohisa; Watanabe, Tetsuya [The Graduate University of Advanced Studies (SOKENDAI) (Japan); Nakamura, Nobuyuki, E-mail: n-nakamu@ils.uec.ac.jp [Institute for Laser Science, The University of Electro-Communications (Japan)

    2015-11-15

    Intensity ratio of density sensitive emission lines emitted from Fe ions in the extreme ultraviolet region is important for astrophysics applications. We report high-resolution intensity ratio measurements for Fe ions performed at Tokyo EBIT laboratory by employing a flat-field grazing incidence spectrometer. The experimental intensity ratios of Fe X and Fe XII are plotted as a function of electron density for different electron beam currents. The experimental results are compared with the predicted intensity ratios from the model calculations.

  20. Density Measurement of Liquid Ni-Ta Alloys by a Modified Sessile Drop Method

    Institute of Scientific and Technical Information of China (English)

    FANG Liang; XIAO Feng; TAO Zainan; Kusuhiro Mukai

    2005-01-01

    The density of liquid Ni-Ta alloys was measured by using a modified sessile drop method. It is found that the density of the liquid Ni-Ta alloys decreases with the increasing temperature, but increases with the increase of tantalum concentration in the alloys. The molar volume of liquid Ni-Ta binary alloys increases with the increase of temperature and tantalum concentration.

  1. Densities and Kinematic Viscosities for the Systems Benzene + Methyl Formate, Benzene + Ethyl Formate, Benzene + Propyl Formate, and Benzene + Butyl Formate

    DEFF Research Database (Denmark)

    Emmerling, Uwe; Rasmussen, Peter

    1998-01-01

    Densities and kinematic viscosities have been measured for the system benzene + methyl formate at 20°C and for the systems benzene + ethyl formate, benzene + propyl formate, and benzene + butyl formate from 20°C to 50°C. The results for the system benzene + methyl formate have been correlated usi...

  2. IN SITU MEASUREMENTS OF THE SIZE AND DENSITY OF TITAN AEROSOL ANALOGS

    Energy Technology Data Exchange (ETDEWEB)

    Hoerst, S. M.; Tolbert, M. A, E-mail: sarah.horst@colorado.edu [Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, CO (United States)

    2013-06-10

    The organic haze produced from complex CH{sub 4}/N{sub 2} chemistry in the atmosphere of Titan plays an important role in processes that occur in the atmosphere and on its surface. The haze particles act as condensation nuclei and are therefore involved in Titan's methane hydrological cycle. They also may behave like sediment on Titan's surface and participate in both fluvial and aeolian processes. Models that seek to understand these processes require information about the physical properties of the particles including their size and density. Although measurements obtained by Cassini-Huygens have placed constraints on the size of the haze particles, their densities remain unknown. We have conducted a series of Titan atmosphere simulation experiments and measured the size, number density, and particle density of Titan aerosol analogs, or tholins, for CH{sub 4} concentrations from 0.01% to 10% using two different energy sources, spark discharge and UV. We find that the densities currently in use by many Titan models are higher than the measured densities of our tholins.

  3. Density-Decomposed Orbital-Free Density Functional Theory for Covalent Systems and Application to Li-Si alloys

    Science.gov (United States)

    Xia, Junchao; Carter, Emily

    2014-03-01

    We propose a density decomposition scheme using a Wang-Govind-Carter (WGC)-based kinetic energy density functional (KEDF) to accurately and efficiently simulate covalent systems within orbital-free (OF) density functional theory (DFT). By using a local, density-dependent scale function, the total density is decomposed into a localized density within covalent bond regions and a flattened delocalized density, with the former described by semilocal KEDFs and the latter treated by the WGC KEDF. The new model predicts reasonable equilibrium volumes, bulk moduli, and phase ordering energies for various semiconductors compared to Kohn-Sham (KS) DFT benchmarks. The surface energy of Si(100) also agrees well with KSDFT. We further apply the model to study mechanical properties of Li-Si alloys, which have been recently recognized as a promising candidate for next-generation anodes of Li-ion batteries with outstanding capacity. We study multiple crystalline Li-Si alloys. The WGCD KEDF predicts accurate cell lattice vectors, equilibrium volumes, elastic moduli, electron densities, alloy formation and Li adsorption energies. Because of its quasilinear scaling, coupled with the level of accuracy shown here, OFDFT appears quite promising for large-scale simulation of such materials phenomena. Office of Naval Research, National Science Foundation, Tigress High Performance Computing Center.

  4. Independent measurement of femoral cortical thickness and cortical bone density using clinical CT.

    Science.gov (United States)

    Treece, G M; Gee, A H

    2015-02-01

    The local structure of the proximal femoral cortex is of interest since both fracture risk, and the effects of various interventions aimed at reducing that risk, are associated with cortical properties focused in particular regions rather than dispersed over the whole bone. Much of the femoral cortex is less than 3mm thick, appearing so blurred in clinical CT that its actual density is not apparent in the data, and neither thresholding nor full-width half-maximum techniques are capable of determining its width. Our previous work on cortical bone mapping showed how to produce more accurate estimates of cortical thickness by assuming a fixed value of the cortical density for each hip. However, although cortical density varies much less over the proximal femur than thickness, what little variation there is leads to errors in thickness measurement. In this paper, we develop the cortical bone mapping technique by exploiting local estimates of imaging blur to correct the global density estimate, thus providing a local density estimate as well as more accurate estimates of thickness. We also consider measurement of cortical mass surface density and the density of trabecular bone immediately adjacent to the cortex. Performance is assessed with ex vivo clinical QCT scans of proximal femurs, with true values derived from high resolution HRpQCT scans of the same bones. We demonstrate superior estimation of thickness than is possible with alternative techniques (accuracy 0.12 ± 0.39 mm for cortices in the range 1-3mm), and that local cortical density estimation is feasible for densities >800 mg/cm(3).

  5. A Raspberry Pi Based Portable Endoscopic 3D Measurement System

    Directory of Open Access Journals (Sweden)

    Jochen Schlobohm

    2016-07-01

    Full Text Available Geometry measurements are very important to monitor a machine part’s health and performance. Optical measurement system have several advantages for the acquisition of a parts geometry: measurement speed, precision, point density and contactless operation. Measuring parts inside of assembled machines is also desirable to keep maintenance cost low. The Raspberry Pi is a small and cost efficient computer that creates new opportunities for compact measurement systems. We have developed a fringe projection system which is capable of measuring in very limited space. A Raspberry Pi 2 is used to generate the projection patterns, acquire the image and reconstruct the geometry. Together with a small LED projector, the measurement system is small and easy to handle. It consists of off-the-shelf products which are nonetheless capable of measuring with an uncertainty of less than 100 μ m .

  6. Measurement of powder bed density in powder bed fusion additive manufacturing processes

    Science.gov (United States)

    Jacob, G.; Donmez, A.; Slotwinski, J.; Moylan, S.

    2016-11-01

    Many factors influence the performance of additive manufacturing (AM) processes, resulting in a high degree of variation in process outcomes. Therefore, quantifying these factors and their correlations to process outcomes are important challenges to overcome to enable widespread adoption of emerging AM technologies. In the powder bed fusion AM process, the density of the powder layers in the powder bed is a key influencing factor. This paper introduces a method to determine the powder bed density (PBD) during the powder bed fusion (PBF) process. A complete uncertainty analysis associated with the measurement method was also described. The resulting expanded measurement uncertainty, U PBD (k  =  2), was determined as 0.004 g · cm-3. It was shown that this expanded measurement uncertainty is about three orders of magnitude smaller than the typical powder bed density. This method enables establishing correlations between the changes in PBD and the direction of motion of the powder recoating arm.

  7. Plasma dynamics near critical density inferred from direct measurements of laser hole boring.

    Science.gov (United States)

    Gong, Chao; Tochitsky, Sergei Ya; Fiuza, Frederico; Pigeon, Jeremy J; Joshi, Chan

    2016-06-01

    We have used multiframe picosecond optical interferometry to make direct measurements of the hole boring velocity, v_{HB}, of the density cavity pushed forward by a train of CO_{2} laser pulses in a near critical density helium plasma. As the pulse train intensity rises, the increasing radiation pressure of each pulse pushes the density cavity forward and the plasma electrons are strongly heated. After the peak laser intensity, the plasma pressure exerted by the heated electrons strongly impedes the hole boring process and the v_{HB} falls rapidly as the laser pulse intensity falls at the back of the laser pulse train. A heuristic theory is presented that allows the estimation of the plasma electron temperature from the measurements of the hole boring velocity. The measured values of v_{HB}, and the estimated values of the heated electron temperature as a function of laser intensity are in reasonable agreement with those obtained from two-dimensional numerical simulations.

  8. Vibration-Induced Conductivity Fluctuation Measurement for Soil Bulk Density Analysis

    CERN Document Server

    Kishne, Andrea Sz; Chang, Hung-Chih; Kish, Laszlo B

    2007-01-01

    Soil bulk density affects water storage, water and nutrient movement, and plant root activity in the soil profile. Its measurement is difficult in field conditions. Vibration-induced conductivity fluctuation was investigated to quantify soil bulk density with possible field applications in the future. The AC electrical conductivity of soil was measured using a pair of blade-like electrodes while exposing the soil to periodic vibration. The blades were positioned longitudinally and transversally to the direction of the induced vibration to enable the calculation of a normalized index. The normalized index was expected to provide data independent from the vibration strength and to reduce the effect of soil salinity and water content. The experiment was conducted on natural and salinized fine sand at two moisture conditions and four bulk densities. The blade-shaped electrodes improved electrode-soil contact compared to cylindrical electrodes, and thereby, reduced measurement noise. Simulations on a simplified re...

  9. Transport through correlated systems with density functional theory

    Science.gov (United States)

    Kurth, S.; Stefanucci, G.

    2017-10-01

    We present recent advances in density functional theory (DFT) for applications in the field of quantum transport, with particular emphasis on transport through strongly correlated systems. We review the foundations of the popular Landauer–Büttiker(LB)  +  DFT approach. This formalism, when using approximations to the exchange-correlation (xc) potential with steps at integer occupation, correctly captures the Kondo plateau in the zero bias conductance at zero temperature but completely fails to capture the transition to the Coulomb blockade (CB) regime as the temperature increases. To overcome the limitations of LB  +  DFT, the quantum transport problem is treated from a time-dependent (TD) perspective using TDDFT, an exact framework to deal with nonequilibrium situations. The steady-state limit of TDDFT shows that in addition to an xc potential in the junction, there also exists an xc correction to the applied bias. Open shell molecules in the CB regime provide the most striking examples of the importance of the xc bias correction. Using the Anderson model as guidance we estimate these corrections in the limit of zero bias. For the general case we put forward a steady-state DFT which is based on one-to-one correspondence between the pair of basic variables, steady density on and steady current across the junction and the pair local potential on and bias across the junction. Like TDDFT, this framework also leads to both an xc potential in the junction and an xc correction to the bias. Unlike TDDFT, these potentials are independent of history. We highlight the universal features of both xc potential and xc bias corrections for junctions in the CB regime and provide an accurate parametrization for the Anderson model at arbitrary temperatures and interaction strengths, thus providing a unified DFT description for both Kondo and CB regimes and the transition between them.

  10. Microscopic Faraday rotation measurement system using pulsed magnetic fields.

    Science.gov (United States)

    Egami, Shigeki; Watarai, Hitoshi

    2009-09-01

    Microscopic Faraday rotation measurement system using a pulsed magnetic field has been constructed, which can be applied to micron sized diamagnetic and paramagnetic materials. A pulsed magnetic coil could generate a maximum magnetic flux density of about 12 T. The performance of the microscopic Faraday rotation apparatus was demonstrated by the measurement of the Verdet constant V of a polystyrene particle, after the calibration of the pulsed magnetic flux density using a glass plate as a standard material. Also, the magneto-optical rotation dispersion of some diamagnetic substances have been measured and analyzed with V=alambda(-2)+b. The values of a and b were compared to their magnetic susceptibilities.

  11. Measurements of solar flux density distribution on a plane receiver due to a flat heliostat

    Energy Technology Data Exchange (ETDEWEB)

    Elsayed, M.M.; Fathalah, K.A.; Al-Rabghi, O.M. [King Abdulaziz Univ., Jeddah (Saudi Arabia)

    1995-06-01

    An experimental facility is designed and manufactured to measure the solar flux density distribution on a central flat receiver due to a single flat heliostat. The tracking mechanism of the heliostat is controlled by two stepping motors, one for tilt angle control and the other for azimuth angle control. A x-y traversing mechanism is also designed and mounted on a vertical central receiver plane, where the solar flux density is to be measured. A miniature solar sensor is mounted on the platform of the traversing mechanism, where it is used to measure the solar flux density distribution on the receiver surface. The sensor is connected to a data acquisition card in a host computer. The two stepping motors of the heliostat tracking mechanism and the two stepping motors of the traversing mechanism are all connected to a controller card in the same host computer. A software `TOWER` is prepared to let the heliostat track the sun, move the platform of the traversing mechanism to the points of a preselected grid, and to measure the solar flux density distribution on the receiver plane. Measurements are carried out using rectangular flat mirrors of different dimensions at several distances from the central receiver. Two types of images were identified on the receiver plane - namely, apparent (or visible) and mirror-reflected radiation images. Comparison between measurements and a mathematical model validates the mathematical model. 13 refs., 12 figs., 1 tab.

  12. Use of micro-photoluminescence as a contactless measure of the 2D electron density in a GaAs quantum well

    Science.gov (United States)

    Kamburov, D.; Baldwin, K. W.; West, K. W.; Lyon, S.; Pfeiffer, L. N.; Pinczuk, A.

    2017-06-01

    We compare micro-photoluminescence (μPL) as a measure of the electron density in a clean, two-dimensional (2D) system confined in a GaAs quantum well (QW) to the standard magneto-transport technique. Our study explores the PL shape evolution across a number of molecular beam epitaxy-grown samples with different QW widths and 2D electron densities and notes its correspondence with the density obtained in magneto-transport measurements on these samples. We also measure the 2D density in a top-gated quantum well sample using both PL and transport and find that the two techniques agree to within a few percent over a wide range of gate voltages. We find that the PL measurements are sensitive to gate-induced 2D density changes on the order of 109 electrons/cm2. The spatial resolution of the PL density measurement in our experiments is 40 μm, which is already substantially better than the millimeter-scale resolution now possible in spatial density mapping using magneto-transport. Our results establish that μPL can be used as a reliable high spatial resolution technique for future contactless measurements of density variations in a 2D electron system.

  13. Special performance measurements of a {open_quotes}high-tube-density{close_quotes} condenser

    Energy Technology Data Exchange (ETDEWEB)

    Smoglie, C.; Novak, W.; Kreidler, T.; Arnal, M. [ABB Power Generation, Ltd., Baden (Switzerland)] [and others

    1996-08-01

    Performance measurements of a High-Tube-Density (HTD) Condenser have been made and evaluated. The condenser is an example of the ABB modular tube-bundle design and is derived from the established, high-performance ABB CM Condenser. It is a two-pass condenser designed for situations where space limitations make it necessary to have horizontally divided waterboxes. It is further characterized by its compactness which is a result in part, of the high tubesheet drill-out coefficient. As a part of continuing development work it was of particular interest to determine the performance characteristics of the condenser while in normal operation. Tests at seven different electrical loads were carried out for a load range of 65% to 98%. The experimental data show very good agreement with design values. Measured values of the cooling water pressure loss and overall heat transfer coefficient were superior to design values. Very satisfactory results for condensate subcooling and O{sub 2} concentration were also obtained. A vacuum drop test demonstrated that the condenser is well sealed and that the venting system capability is sufficient. 6 refs., 9 figs., 11 tabs.

  14. The Keck+Magellan Survey for Lyman Limit Absorption III: Sample Definition and Column Density Measurements

    CERN Document Server

    Prochaska, J Xavier; Fumagalli, Michele; Bernstein, Rebecca A; Burles, Scott M

    2015-01-01

    We present an absorption-line survey of optically thick gas clouds -- Lyman Limit Systems (LLSs) -- observed at high dispersion with spectrometers on the Keck and Magellan telescopes. We measure column densities of neutral hydrogen NHI and associated metal-line transitions for 157 LLSs at z=1.76-4.39 restricted to 10^17.3 < NHI < 10^20.3. An empirical analysis of ionic ratios indicates an increasing ionization state of the gas with decreasing NHI and that the majority of LLSs are highly ionized, confirming previous expectations. The Si^+/H^0 ratio spans nearly four orders-of-magnitude, implying a large dispersion in the gas metallicity. Fewer than 5% of these LLSs have no positive detection of a metal transition; by z~3, nearly all gas that is dense enough to exhibit a very high Lyman limit opacity has previously been polluted by heavy elements. We add new measurements to the small subset of LLS (~5-10) that may have super-solar abundances. High Si^+/Fe^+ ratios suggest an alpha-enhanced medium whereas ...

  15. Thermodynamic magnetization of two-dimensional electron gas measured over wide range of densities

    OpenAIRE

    Reznikov, M.; Kuntsevich, A. Yu.; Teneh, N.; Pudalov, V. M.

    2011-01-01

    We report measurements of dm/dn in Si MOSFET, where m is the magnetization of the two-dimensional electron gas and n is its density. We extended the density range of measurements from well in the metallic to deep in the insulating region. The paper discusses in detail the conditions under which this extension is justified, as well as the corrections one should make to extract dm/dn properly. At low temperatures, dm/dn was found to be strongly nonlinear already in weak magnetic fields, on a sc...

  16. Laboratory measurements of density-driven convection in analogy with solubility trapping of geologically sequestered CO2

    Science.gov (United States)

    Rasmusson, Maria; Fagerlund, Fritjof; Rasmusson, Kristina; Niemi, Auli

    2016-04-01

    Density-driven convection is of interest to several areas of groundwater-science: nuclear waste storage, industrial waste disposal, deep geothermal energy extraction, and seawater intrusion into coastal aquifers. Lately it has been identified to accelerate the rate of CO2 solubility trapping for geological CO2 storage in deep saline aquifers. We present an experimental method based on the light transmission technique and an analogue system design that enable comprehensive study of solutally induced density-driven convection in saturated porous media. The system design affords an examination of the convective process in general as well as a two-dimensional laboratory analogue for field phenomena. Furthermore, the method can be used to verify numerical results from density-driven flow simulation codes as part of benchmarking. With application to geological CO2 storage, we show how the method is used to measure density-driven convection in both homogenous and heterogeneous porous media and for different Rayleigh numbers. The results demonstrate that the solute concentration distribution in the system can be accurately determined with high spatial and temporal resolution. Thus, the onset time of convection, mass flux and flow dynamics can be quantified for different systems under well-controlled conditions.

  17. Toward in Situ Measurement of the Density of Liquid Benzene Using Optical Kerr Effect Spectroscopy.

    Science.gov (United States)

    Bender, John S; Cohen, Samuel R; He, Xiaoxiao; Fourkas, John T; Coasne, Benoit

    2016-09-01

    The high-frequency portion of the optical Kerr effect (OKE) spectrum of benzene shifts to higher frequency with decreasing temperature at constant pressure. This behavior has been interpreted previously in terms of an increase in librational frequencies due to the decrease in free volume with liquid densification. However, decreasing temperature also provides less access to the more repulsive portion of the intermolecular potential, which would cause the blue edge of the spectrum to red-shift. To explore the relative importance of these phenomena, molecular dynamics simulations of benzene are used to isolate the effects of temperature and density on the spectrum. The simulations show that, at constant density, the high-frequency portion of the spectrum shifts to lower frequency with decreasing temperature. In contrast, at constant temperature, the high-frequency portion of the spectrum shifts to higher frequency with increasing density. These results indicate that density plays a greater role in determining the position of the blue edge of the low-frequency Raman spectrum of benzene than does temperature. Empirical fits show that the effects of changing density or temperature are similar in experimental and simulated OKE spectra. Furthermore, line-shape analysis of simulated spectra under isochoric and isothermal conditions shows that the effects of density and temperature are separable, suggesting that OKE spectroscopy is a viable technique for in situ measurement of the density of van der Waals liquids.

  18. A novel ultrasonic method for measuring breast density and breast cancer risk

    Science.gov (United States)

    Glide-Hurst, Carri K.; Duric, Neb; Littrup, Peter J.

    2008-03-01

    Women with high mammographic breast density are at 4- to 6-fold increased risk of developing breast cancer compared to women with fatty breasts. However, current breast density estimations rely on mammography, which cannot provide accurate volumetric breast representation. Therefore, we explored two techniques of breast density evaluation via ultrasound tomography. A sample of 93 patients was imaged with our clinical prototype; each dataset contained 45-75 tomograms ranging from near the chest wall through the nipple. Whole breast acoustic velocity was determined by creating image stacks and evaluating the sound speed frequency distribution. Ultrasound percent density (USPD) was determined by segmenting high sound speed areas from each tomogram using k-means clustering, integrating over the entire breast, and dividing by total breast area. Both techniques were independently evaluated using two mammographic density measures: (1) qualitative, determined by a radiologist's visual assessment using BI-RADS Categories, and (2) quantitative, via semi-automatic segmentation to calculate mammographic percent density (MPD) for craniocaudal and medio-lateral oblique mammograms. ~140 m/s difference in acoustic velocity was observed between fatty and dense BI-RADS Categories. Increased sound speed was found with increased BI-RADS Category and quantitative MPD. Furthermore, strong positive associations between USPD, BI-RADS Category, and calculated MPD were observed. These results confirm that utilizing sound speed, both for whole-breast evaluation and segmenting locally, can be implemented to evaluate breast density.

  19. SOL plasma measurements during high density and long duration current drive on TRIAM-1M

    Energy Technology Data Exchange (ETDEWEB)

    Takemura, Takeharu; Kawasaki, Shoji; Jotaki, Eriko; Makino, Ken-ichi; Sakamoto, Mizuki; Nakamura, Kazuo; Nakamura, Yukio; Itoh, Sanae; Itoh, Satoshi [Kyushu Univ., Kasuga, Fukuoka (Japan). Research Inst. for Applied Mechanics

    1997-02-01

    In the superconducting, strong magnetic field tokamak, TRIAM-1M, for the purpose of maintaining high density plasma for long time, the current drive experiment using 8.2 GHz lower hybrid wave has been carried out. For maintaining high density plasma for long time, it is indispensable to control gas puff and recycling from wall, as these are closely related to the structure and characteristics of boundary plasma including scrape-off layer (SOL). In this study, in the high density, long time current drive using 8.2 GHz lower hybrid wave, the electron density and electron temperature of SOL plasma were measured by using double probe, and the z-direction distribution and the toroidal magnetic field dependence of the electron density and electron temperature of SOL plasma were examined and compared with OH discharge. Also the dependence of the electron density of SOL plasma on the phase difference in a adjoining waveguide tubes was examined. The experimental setup and the double probe theory are explained. The experimental results of the change with time lapse, the z-direction distribution and the magnetic field dependence of the electron density and electron temperature of SOL plasma are reported. (K.I.)

  20. Measurement of solar wind electron density and temperature in the shocked region of Venus and the density and temperature of photoelectrons within the ionosphere of Venus

    Science.gov (United States)

    Knudsen, William C.; Jones, Douglas E.; Peterson, Bryan G.; Knadler, Charles E.

    2016-08-01

    Presented herein are measurements of the solar wind electron number density and temperature near and within the bow shock of Venus. The measurements were made by the Pioneer Venus mission Orbiter Retarding Potential Analyzer operating in its suprathermal electron mode. The measurements are essentially point measurements. The spacecraft travels approximately 0.8 km during the 0.1 s time interval required to record a single I-V curve. The dual measurement of a density and temperature is obtained from one sweep by least squares fitting a mathematical Maxwellian expression to the I-V curve. The distance between successive measurements is approximately 100 km. In many orbits, when the spacecraft is crossing or traveling within the bow shock, the derived densities and temperatures (high density, high temperature (HDHT)) are large, densities of the order of 100 cm-3 and temperatures of the order of several hundred eV. We interpret these HDHT measurements as measurements in regions where the large, directed kinetic energy of the solar wind ions is being degraded into randomized, more thermal-like energy distributions of the electrons and ions through wave-particle interactions. The HDHT values define the electron energy distribution in the limited energy interval 0 to 50 eV. We assume that the underlying electron flux distributions are flat topped like those measured in the Earth's bow shock. We also report densities and temperatures of EUV produced photoelectron energy distributions measured within the ionosphere.

  1. [Rapid measurements of CO2 flux density and water use efficiency of crop community].

    Science.gov (United States)

    Zhu, Zhilin; Sun, Xiaomin; Zhang, Renhua; Su, Hongbo; Tang, Xinzai

    2004-09-01

    In this paper, Eddy Correlation (EC) method was employed to measure the latent heat and CO2 flux density and to calculate Water Use Efficiency (WUE) of winter wheat community in Yucheng district, Shandong Province in 1997. The results showed that the CO2 flux density had an obvious diurnal change, with a maximum about 1.5 mg x s(-1) x m(-2), which appeared at about 9:00-10:00 am in general. The WUE of wheat community presented a fall trend from morning to afternoon, and the CO2 flux density and WUE also had an obvious seasonal change, being lower in the early and late growth stages, and higher in the middle growth stage. The ranges of daily mean CO2 flux density and WUE were 0.2-0.9 mg x s(-1) x m(-2) and 5-20 gCO2 x kg(-1) H2O, respectively.

  2. Partial-reflection studies of D-region winter variability. [electron density measurements

    Science.gov (United States)

    Denny, B. W.; Bowhill, S. A.

    1973-01-01

    D-region electron densities were measured from December, 1972, to July, 1973, at Urbana, Illinois (latitude 40.2N) using the partial-reflection technique. During the winter, electron densities at altitudes of 72, 76.5, and 81 km show cyclical changes with a period of about 5 days that are highly correlated between these altitudes, suggesting that the mechanism responsible for the winter anomaly in D-region ionization applies throughout this height region. From January 13 to February 3, a pronounced wave-like variation occurred in the partial-reflection measurements, apparently associated with a major stratospheric warming that developed in that period. During the same time period, a traveling periodic variation is observed in the 10-mb height; it is highly correlated with the partial-reflection measurements. Electron density enhancements occur approximately at the same time as increases in the 10-mb height. Comparison of AL and A3 absorption measurements with electron density measurements below 82 km indicates that the winter anomaly in D-region ionization is divided into two types. Type 1, above about 82 km, extends horizontally for about 200 km while type 2, below about 82 km, extends for a horizontal scale of at least 1000 km.

  3. Thermophysical properties of medium density fiberboards measured by quasi-stationary method: experimental and numerical evaluation

    Science.gov (United States)

    Troppová, Eva; Tippner, Jan; Hrčka, Richard

    2017-01-01

    This paper presents an experimental measurement of thermal properties of medium density fiberboards with different thicknesses (12, 18 and 25 mm) and sample sizes (50 × 50 mm and 100 × 100 mm) by quasi-stationary method. The quasi-stationary method is a transient method which allows measurement of three thermal parameters (thermal conductivity, thermal diffusivity and heat capacity). The experimentally gained values were used to verify a numerical model and furthermore served as input parameters for the numerical probabilistic analysis. The sensitivity of measured outputs (time course of temperature) to influential factors (density, heat transfer coefficient and thermal conductivities) was established and described by the Spearman's rank correlation coefficients. The dependence of thermal properties on density was confirmed by the data measured. Density was also proved to be an important factor for sensitivity analyses as it highly correlated with all output parameters. The accuracy of the measurement method can be improved based on the results of the probabilistic analysis. The relevancy of the experiment is mainly influenced by the choice of a proper ratio between thickness and width of samples.

  4. Novel analysis technique for measuring edge density fluctuation profiles with reflectometry in the Large Helical Device

    Science.gov (United States)

    Creely, A. J.; Ida, K.; Yoshinuma, M.; Tokuzawa, T.; Tsujimura, T.; Akiyama, T.; Sakamoto, R.; Emoto, M.; Tanaka, K.; Michael, C. A.

    2017-07-01

    A new method for measuring density fluctuation profiles near the edge of plasmas in the Large Helical Device (LHD) has been developed utilizing reflectometry combined with pellet-induced fast density scans. Reflectometer cutoff location was calculated by proportionally scaling the cutoff location calculated with fast far infrared laser interferometer (FIR) density profiles to match the slower time resolution results of the ray-tracing code LHD-GAUSS. Plasma velocity profile peaks generated with this reflectometer mapping were checked against velocity measurements made with charge exchange spectroscopy (CXS) and were found to agree within experimental uncertainty once diagnostic differences were accounted for. Measured density fluctuation profiles were found to peak strongly near the edge of the plasma, as is the case in most tokamaks. These measurements can be used in the future to inform inversion methods of phase contrast imaging (PCI) measurements. This result was confirmed with both a fixed frequency reflectometer and calibrated data from a multi-frequency comb reflectometer, and this method was applied successfully to a series of discharges. The full width at half maximum of the turbulence layer near the edge of the plasma was found to be only 1.5-3 cm on a series of LHD discharges, less than 5% of the normalized minor radius.

  5. Measurement of the density of animal bone by absorptiometry: some preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Gonnelli, Eduardo; Costa, Vladimir Eliodoro; Rezende, Marcos Antonio de; Hormaza, Joel Mesa; Machado, Vania Maria de Vasconcelos [UNESP, Botucatu, SP (Brazil)

    2009-07-01

    Full text: Measurement of bone mineral content for different bone types at various sites of the human body has been extensively studied in the last three decades. There are several methods for the determination of bone mineral density and strength by using non ionizing and ionizing radiation, as well as by other techniques, such as ultrasound. In humans, the accuracy and precision of those kind of measurement varies between the methods and, in all the cases, reference values are adopted as a function of sex, age and nutritional parameters. In this work, we have presented some preliminary results of the measurement of the density in animal bone obtained experimentally by absorptiometry, which is based on the fact that attenuation of a gamma ray beam is proportional to the coefficient of mass attenuation of an object in the path of the beam: with the increase of the density of the object, less photons will pass through it. Starting from this, we can calculate the bone mineral density in any point of the material. The radionuclide (through a sealed and shielded source of the radioisotope {sup 241}Am with an activity of 7.4 GBq and an energy of 59.6 keV) is the photons source and a scintillation detector quantify the transmitted photons through the bone to determine the density. The results obtained experimentally were compared with theoretical ones calculated by simulation with the MCNPX based Monte Carlo transport code. (author)

  6. Systematic comparison between line integrated densities measured with interferometry and polarimetry at JET.

    Science.gov (United States)

    Brombin, M; Boboc, A; Murari, A; Zilli, E; Giudicotti, L

    2009-06-01

    A systematic comparison between the line integrated electron density derived from interferometry and polarimetry at JET has been carried out. For the first time the reliability of the measurements of the Cotton-Mouton effect has been analyzed for a wide range of main plasma parameters and the possibility to evaluate the electron density directly from polarimetric data has been studied. The purpose of this work is to recover the interferometric data with the density derived from the measured Cotton-Mouton effect, when the fringe jump phenomena occur. The results show that the difference between the line integrated electron density from interferometry and polarimetry is with one fringe (1.143 x 10(19) m(-2)) for more than 90% of the cases. It is possible to consider polarimetry as a satisfactory alternative method to interferometry to measure the electron density and it could be used to recover interferometric signal when a fringe jumps occurs, preventing difficulties for the real-time control of many experiments at the JET machine.

  7. [Flow density measurements using optical coherence tomography angiography : Impact of age and gender].

    Science.gov (United States)

    Alnawaiseh, M; Brand, C; Lauermann, J L; Eter, N

    2017-07-19

    This article presents the normative data for flow density measured using optical coherence tomography (OCT) angiography and the impact of age and gender is evaluated. In this study 58 eyes from 58 healthy volunteers with no history of any ocular disease or ocular surgery were included. The OCT angiography imaging was performed using the RTVue XR Avanti with the AngioVue (Optovue, Fremont, CA). The macula was imaged using a 3 × 3 mm scan, and the flow density data in the superficial retinal OCT angiogram and deep retinal OCT angiogram were extracted and analyzed. The groups were compared using the Mann-Whitney U‑test and the degree of correlation between two variables was expressed as the Spearman's correlation coefficient (rSp.) RESULTS: The mean subject age was 38.3 ± 14.6 years. The flow density (whole en face) in the deep retinal OCT angiogram was significantly higher compared to the flow density in the superficial retinal OCT angiogram (p density in superficial and deep OCT angiograms of the macula between males (n = 27) and females (n = 31). There was a significant correlation between the flow density in the deep retinal OCT angiogram and age (rSp. = -0.41, p = 0.001). Whereas gender has no impact on the flow density measured using OCT angiography, there was a significant correlation between the flow density in the deep retinal OCT angiogram and age.

  8. Exact and LDA entanglement of tailored densities in an interacting one-dimensional electron system

    Energy Technology Data Exchange (ETDEWEB)

    Coe, J P; D' Amico, I, E-mail: jpc503@york.ac.u, E-mail: ida500@york.ac.u [Department of Physics, University of York, York YO10 5DD (United Kingdom)

    2010-01-01

    We calculate the 'exact' potential corresponding to a one-dimensional interacting system of two electrons with a specific, tailored density. We use one-dimensional density-functional theory with a local-density approximation (LDA) on the same system and calculate densities and energies, which are compared with the 'exact' ones. The 'interacting-LDA system'[4] corresponding to the LDA density is then found and its potential compared with the original one. Finally we calculate and compare the spatial entanglement of the electronic systems corresponding to the interacting-LDA and original interacting system.

  9. Free-space reflection method for measuring moisture content and bulk density of particulate materials at microwave frequency

    Science.gov (United States)

    Li, Chenxiao; Han, Bing; Zhang, Tao

    2015-03-01

    A measurement system based on free-space reflection method is designed for simultaneous and independent determination of moisture content and bulk density of particulate materials. The proposed system consists of microwave cavity oscillator, horn antenna, slide rail, sample holder, mixer, and digital meter. Sand and rice with different moisture contents and bulk densities are chosen as samples. Calibration models for moisture content and bulk density are proposed according to the measurement of the position of the minimum of the traveling-standing wave and the ratio of the maximum-to-minimum field strength of the traveling-standing wave at different temperatures. The moisture constant, ranging from 0% to 24.6%, is obtained with a coefficient of determination (R2) greater than 0.982 and a standard error of prediction (SEP) value of less than 0.695%. The bulk density, ranging from 0.501 g/cm3 to 1.822 g/cm3, is determined with a R2 ≥ 0.961 and a SEP value ranging from 0.0144 g/cm3 to 0.0382 g/cm3 for different samples.

  10. Remotely operable compact instruments for measuring atmospheric CO2 and CH4 column densities at surface monitoring sites

    Directory of Open Access Journals (Sweden)

    Y. Matsumi

    2010-04-01

    Full Text Available Remotely operable compact instruments for measuring atmospheric CO2 and CH4 column densities were developed in two independent systems: one utilizing a grating-based desktop optical spectrum analyzer (OSA with a resolution enough to resolve rotational lines of CO2 and CH4 in the region of 1565–1585 and 1674–1682 nm, respectively; the other is an application of an optical fiber Fabry-Perot interferometer (FFPI to the CO2 column density. Direct sunlight was collimated via a small telescope installed on a portable sun tracker and then transmitted through an optical fiber into the OSA or the FFPI for optical analysis. The near infrared spectra of the OSA were retrieved by a least squares spectral fitting algorithm. The CO2 and CH4 column densities deduced were in excellent agreement with those measured by a Fourier transform spectrometer with high resolution. The rovibronic lines in the wavelength region of 1570–1575 nm were analyzed by the FFPI. The I0 and I values in the Beer-Lambert law equation to obtain CO2 column density were deduced by modulating temperature of the FFPI, which offered column CO2 with the statistical error less than 0.2% for six hours measurement.

  11. Remotely operable compact instruments for measuring atmospheric CO2 and CH4 column densities at surface monitoring sites

    Directory of Open Access Journals (Sweden)

    I. Morino

    2010-08-01

    Full Text Available Remotely operable compact instruments for measuring atmospheric CO2 and CH4 column densities were developed in two independent systems: one utilizing a grating-based desktop optical spectrum analyzer (OSA with a resolution enough to resolve rotational lines of CO2 and CH4 in the regions of 1565–1585 and 1674–1682 nm, respectively; the other is an application of an optical fiber Fabry-Perot interferometer (FFPI to obtain the CO2 column density. Direct sunlight was collimated via a small telescope installed on a portable sun tracker and then transmitted through an optical fiber into the OSA or the FFPI for optical analysis. The near infrared spectra of the OSA were retrieved by a least squares spectral fitting algorithm. The CO2 and CH4 column densities deduced were in excellent agreement with those measured by a Fourier transform spectrometer with high resolution. The rovibronic lines in the wavelength region of 1570–1575 nm were analyzed by the FFPI. The I0 and I values in the Beer-Lambert law equation to obtain CO2 column density were deduced by modulating temperature of the FFPI, which offered column CO2 with the statistical error less than 0.2% for six hours measurement.

  12. Measurement of Single Cell Refractive Index, Dry Mass, Volume, and Density Using a Transillumination Microscope

    Science.gov (United States)

    Phillips, Kevin G.; Jacques, Steven L.; McCarty, Owen J. T.

    2012-09-01

    Phase contrast microscopy has become ubiquitous in the field of biology, particularly in qualitative investigations of cellular morphology. However, the use of quantitative phase retrieval methods and their connection to cellular refractive index and dry mass density remain under utilized. This is due in part to the restriction of phase and cellular mass determination to custom built instruments, involved mathematical analysis, and prohibitive sample perturbations. We introduce tomographic bright field imaging, an accessible optical imaging technique enabling the three dimensional measurement of cellular refractive index and dry mass density using a standard transillumination optical microscope. The validity of the technique is demonstrated on polystyrene spheres. The technique is then applied to the measurement of the refractive index, dry mass, volume, and density of red blood cells. This optical technique enables a simple and robust means to perform quantitative investigations of engineered and biological specimens in three dimensions using standard optical microscopes.

  13. A Catalytic Sensor for Measurement of Radical Density in CO2 Plasmas

    Directory of Open Access Journals (Sweden)

    Alenka Vesel

    2012-11-01

    Full Text Available A catalytic sensor for the measurement of radical density in weakly ionized CO2 plasmas, created in a low-pressure electrodeless discharge, is presented. The CO2 plasma was created in a 4 cm wide borosilicate glass tube inside a copper coil connected to a radio frequency generator operating at 27.12 MHz with a nominal power of 250 W. The dissociation fraction of the CO2 molecules was measured in the early afterglow at pressures ranging from 10 Pa to 100 Pa, and at distances of up to 35 cm along the gas stream from the glowing plasma. The radical density peaked (2 × 1020 m–3 at 80 Pa. The density quickly decreased with increasing distance from the glowing plasma despite a rather large drift velocity. The dissociation fraction showed similar behavior, except that the maximum was obtained at somewhat lower pressure. The results were explained by rather intense surface recombination of radicals.

  14. Phase space density as a measure of cooling performance for the international muon ionization cooling experiment

    Energy Technology Data Exchange (ETDEWEB)

    Berg, J. S. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2015-05-03

    The International Muon Ionization Cooling Experiment (MICE) is an experiment to demonstrate ionization cooling of a muon beam in a beamline that shares characteristics with one that might be used for a muon collider or neutrino factory. I describe a way to quantify cooling performance by examining the phase space density of muons, and determining how much that density increases. This contrasts with the more common methods that rely on the covariance matrix and compute emittances from that. I discuss why a direct measure of phase space density might be preferable to a covariance matrix method. I apply this technique to an early proposal for the MICE final step beamline. I discuss how matching impacts the measured performance.

  15. Measuring the Density of a Molecular Cluster Injector via Visible Emission from an Electron Beam

    Energy Technology Data Exchange (ETDEWEB)

    Lundberg, D. P.; Kaita, R.; Majeski, R. M.; Stotler, D. P.

    2010-06-28

    A method to measure the density distribution of a dense hydrogen gas jet is pre- sented. A Mach 5.5 nozzle is cooled to 80K to form a flow capable of molecular cluster formation. A 250V, 10mA electron beam collides with the jet and produces Hα emission that is viewed by a fast camera. The high density of the jet, several 1016cm-3, results in substantial electron depletion, which attenuates the Hα emission. The attenuated emission measurement, combined with a simplified electron-molecule collision model, allows us to determine the molecular density profile via a simple iterative calculation.

  16. On the reliability of observational measurements of column density probability distribution functions

    CERN Document Server

    Ossenkopf, Volker; Schneider, Nicola; Federrath, Christoph; Klessen, Ralf S

    2016-01-01

    Probability distribution functions (PDFs) of column densities are an established tool to characterize the evolutionary state of interstellar clouds. Using simulations, we show to what degree their determination is affected by noise, line-of-sight contamination, field selection, and the incomplete sampling in interferometric measurements. We solve the integrals that describe the convolution of a cloud PDF with contaminating sources and study the impact of missing information on the measured column density PDF. The effect of observational noise can be easily estimated and corrected for if the root mean square (rms) of the noise is known. For $\\sigma_{noise}$ values below 40\\,\\% of the typical cloud column density, $N_{peak}$, this involves almost no degradation of the accuracy of the PDF parameters. For higher noise levels and narrow cloud PDFs the width of the PDF becomes increasingly uncertain. A contamination by turbulent foreground or background clouds can be removed as a constant shield if the PDF of the c...

  17. Electron density measurement in gas discharge plasmas by optical and acoustic methods

    Science.gov (United States)

    Biagioni, A.; Anania, M. P.; Bellaveglia, M.; Chiadroni, E.; Cianchi, A.; Di Giovenale, D.; Di Pirro, G.; Ferrario, M.; Filippi, F.; Mostacci, A.; Pompili, R.; Shpakov, V.; Vaccarezza, C.; Villa, F.; Zigler, A.

    2016-08-01

    Plasma density represents a very important parameter for both laser wakefield and plasma wakefield acceleration, which use a gas-filled capillary plasma source. Several techniques can be used to measure the plasma density within a capillary discharge, which are mainly based on optical diagnostic methods, as for example the well-known spectroscopic method using the Stark broadening effect. In this work, we introduce a preliminary study on an alternative way to detect the plasma density, based on the shock waves produced by gas discharge in a capillary. Firstly, the measurements of the acoustic spectral content relative to the laser-induced plasmas by a solid target allowed us to understand the main properties of the acoustic waves produced during this kind of plasma generation; afterwards, we have extended such acoustic technique to the capillary plasma source in order to calibrate it by comparison with the stark broadening method.

  18. In Situ Density Measurement of Basaltic Melts at High Pressure by X-ray Absorption Method

    Science.gov (United States)

    Ando, R.; Ohtani, E.; Suzuki, A.; Urakawa, S.; Katayama, Y.

    2004-12-01

    Density of silicate melt at high pressure is one of the most important properties to understand magma migration in the planetary interior. However, because of experimental difficulties, the density of magma at high pressure is poorly known. Katayama et al. (1996) recently developed a new in situ density measurement method for metallic melts, based on the density dependency of X-ray absorption in the sample. In this study, we tried to measure the density of basaltic melt by this absorption method. When X-ray is transmitted to the sample, the intensity of the transmitted X-ray beam (I) is expressed as follows; I=I0exp(-μ ρ t), where I0 is the intensity of incident X-ray beam, μ is the mass absorption coefficient, ρ is the density of the sample, and t is the thickness of the sample. If t and μ are known, we can determine the density of the sample by measuring I and I0. This is the principle of the absorption method for density measurement. In this study, in order to determine t, we used a single crystalline diamond cylinder as a sample capsule, diamond is less compressive and less deformable so that even at high pressure t (thickness of the sample at the point x) is expressed as follows; t = 2*(R02-x2)1/2, R0 is the inner radius of cylinder at the ambient condition, and x is distance from a center of the capsule. And diamond also shows less absorption so that this make it possible to measure the density of silicate melt with smaller absorption coefficient than metallic melts. In order to know the μ of the sample, we measured both densities (ρ ) and absorptions (I/I0) for some glasses and crystals with same composition of the sample at the ambient condition, and calculated as fallows; μ =ln(I/I0)/ρ . Experiments were made at the beamline (BL22XU) of SPring-8. For generation of high pressure and high temperature, we used DIA-type cubic anvil apparatus (SMAP180) there. We used tungsten carbide anvils with the edge-length of 6 mm. The energy of monochromatic X

  19. [A study on image processing of digital radiography and measure of material micro-density directly].

    Science.gov (United States)

    Xia, Ping; Xu, Guang-Ming; Yin, Song; Liu, Sheng-Quan; Xu, Lian-Yuan

    2008-05-01

    Due to the high influents of the device itself and the surrounding environment, the background brightness of the digital radiography image is uniform and the image shows big noise. Therefore, in order to identify digital radiography images precisely, a further image processing is necessary. In this study, adaptive filtering, histogram equalization techniques and difference image methods were used for image processing and the results show that these techniques were useful to denoise, to intensify brightness and to rectify the background. In order to verify the feasibility of these techniques, poplar wood samples of heterogeneous material were used as experimental materials and Micro-density was measured directly by applying the linear relationship between grey scale of DR image and penetrate material density and contrasted with the result of microdensitometer. The results show these techniques were feasible and even gave a more precise measurement on wood micro-density compared to microdensitometer.

  20. Gas Transport Parameters for Landfill Final Cover Soil: Measurements and Model Modification by Dry Bulk Density

    Science.gov (United States)

    Wickramarachchi, P. N.; Kawamoto, K.; Hamamoto, S.; Nagamori, M.; Moldrup, P.; Komatsu, T.

    2011-12-01

    Landfill sites have been emerging in greenhouse warming scenarios as a significant source of atmospheric methane (CH4). Until recently, landfill management strategies have mainly addressed the problem of preventing groundwater contamination and reduction of leachate generation. Being one of the largest sources of anthropogenic CH4 emission, the final cover system should also be designed for minimizing the greenhouse gases migration into the atmosphere or the areas surrounding the landfill while securing the hydraulic performance. Compared to the intensive research efforts on hydraulic performances of landfill final cover soil, few studies about gas transport characteristics of landfill cover soils have been done. However, recent soil-gas studies implied that the effects of soil physical properties such as bulk density (i.e., compaction level), soil particle size are key parameters to understand landfill gaseous performance. The gas exchange through the final cover soils is controlled by advective and diffusive gas transport. Air permeability (ka) governs the advective gas transport while the soil-gas diffusion coefficient (Dp) governs diffusive gas transport. In this study, the effects of compaction level and particle size fraction effects on ka and Dp for landfill final cover soil was investigated. The disturbed soil samples were taken from landfill final cover in Japan. A compaction tests were performed for the soil samples with two different size fractions (content , the soil samples were repacked into soil cores (i.d. 15-cm, length 12-cm, 2120 cm3) at two different compaction levels [(MP):2700 kN/m2 and (SP):600 kN/m2]. After the compaction tests, ka and Dp were measured and then samples were saturated and subsequently drained at different soil-water matric potential of 0.98, 2.94, 9.81, 1235 kPa and with air-dried and oven-dried conditions. Results showed that measured Dp and ka values for the coarser (content. Further, compaction effort was much significant

  1. Molecular Rayleigh Scattering Diagnostic for Dynamic Temperature, Velocity, and Density Measurements

    Science.gov (United States)

    Mielke, Amy R.; Elam, Kristie A.; Sung, Chi-Jen

    2006-01-01

    A molecular Rayleigh scattering technique is developed to measure dynamic gas temperature, velocity, and density in unseeded turbulent flows at sampling rates up to 16 kHz. A high power CW laser beam is focused at a point in an air jet plume and Rayleigh scattered light is collected and spectrally resolved. The spectrum of the light, which contains information about the temperature and velocity of the flow, is analyzed using a Fabry-Perot interferometer. The circular interference fringe pattern is divided into four concentric regions and sampled at 1 and 16 kHz using photon counting electronics. Monitoring the relative change in intensity within each region allows for measurement of gas temperature and velocity. Independently monitoring the total scattered light intensity provides a measure of gas density. A low speed heated jet is used to validate the measurement of temperature fluctuations and an acoustically excited nozzle flow is studied to validate velocity fluctuation measurements. Power spectral density calculations of the property fluctuations, as well as mean and fluctuating quantities are presented. Temperature fluctuation results are compared with constant current anemometry measurements and velocity fluctuation results are compared with constant temperature anemometry measurements at the same locations.

  2. Comparison of neurite density measured by MRI and histology after TBI.

    Directory of Open Access Journals (Sweden)

    Shiyang Wang

    Full Text Available BACKGROUND: Functional recovery after brain injury in animals is improved by marrow stromal cells (MSC which stimulate neurite reorganization. However, MRI measurement of neurite density changes after injury has not been performed. In this study, we investigate the feasibility of MRI measurement of neurite density in an animal model of traumatic brain injury (TBI with and without MSC treatment. METHODS: Fifteen male Wistar rats, were treated with saline (n = 6 or MSCs (n = 9 and were sacrificed at 6 weeks after controlled cortical impact (CCI. Healthy non-CCI rats (n = 5, were also employed. Ex-vivo MRI scans were performed two days after the rats were sacrificed. Multiple-shell hybrid diffusion imaging encoding scheme and spherical harmonic expansion of a two-compartment water diffusion displacement model were used to extract neurite related parameters. Bielshowski and Luxol Fast blue was used for staining axons and myelin, respectively. Modified Morris water maze and neurological severity score (mNSS test were performed for functional evaluation. The treatment effects, the correlations between neurite densities measured by MRI and histology, and the correlations between MRI and functional variables were calculated by repeated measures analysis of variance, the regression correlation analysis tests, and spearman correlation coefficients. RESULTS: Neurite densities exhibited a significant correlation (R(2>0.80, p<1E-20 between MRI and immuno-histochemistry measurements with 95% lower bound of the intra-correlation coefficient (ICC as 0.86. The conventional fractional anisotropy (FA correlated moderately with histological neurite density (R(2 = 0.59, P<1E-5 with 95% lower bound of ICC as 0.76. MRI data revealed increased neurite reorganization with MSC treatment compared with saline treatment, confirmed by histological data from the same animals. mNSS were significantly correlated with MRI neurite density in the hippocampus region

  3. Quasi-optical design for systems to diagnose the electron temperature and density fluctuations on EAST

    Science.gov (United States)

    Cao, Qifo; Liu, Yong; Zhao, Hailin; Zhou, Tianfu; Ti, Ang; Hu, Liqun

    2016-11-01

    A system to simultaneously diagnose the electron temperature and density fluctuations is proposed for Experimental Advanced Superconducting Tokamak device. This system includes a common quasi-optical antenna, a correlation electron cyclotron emission (CECE) system that is used to measure the electron temperature fluctuations and a Doppler backscattering (DBS) system that is used to measure the electron density fluctuations. The frequency range of the proposed CECE system is 108-120 GHz, and this corresponds to a radial coverage of normalized radius ((R - R0)/a, R0 = 1850 mm, a = 450 mm) from 0.2 to 0.67 for the plasma operation with a toroidal magnetic field of 2.26 T. This paper focuses on the design of the quasi-optical antenna and aims at optimizing the poloidal resolution for different frequency bands. An optimum result gives the beam radius for the CECE system of 13-15 mm and this corresponds to a wave number range of kθ < 2.4 cm-1. The beam radius is 20-30 mm for V band (50-75 GHz) and 15-20 mm for W band (75-110 GHz).

  4. Communication: Near-locality of exchange and correlation density functionals for 1- and 2-electron systems

    Science.gov (United States)

    Sun, Jianwei; Perdew, John P.; Yang, Zenghui; Peng, Haowei

    2016-05-01

    The uniform electron gas and the hydrogen atom play fundamental roles in condensed matter physics and quantum chemistry. The former has an infinite number of electrons uniformly distributed over the neutralizing positively charged background, and the latter only one electron bound to the proton. The uniform electron gas was used to derive the local spin density approximation to the exchange-correlation functional that undergirds the development of the Kohn-Sham density functional theory. We show here that the ground-state exchange-correlation energies of the hydrogen atom and many other 1- and 2-electron systems are modeled surprisingly well by a different local spin density approximation (LSDA0). LSDA0 is constructed to satisfy exact constraints but agrees surprisingly well with the exact results for a uniform two-electron density in a finite, curved three-dimensional space. We also apply LSDA0 to excited or noded 1-electron densities, where it works less well. Furthermore, we show that the localization of the exact exchange hole for a 1- or 2-electron ground state can be measured by the ratio of the exact exchange energy to its optimal lower bound.

  5. Density functional theory for polymeric systems in 2D.

    Science.gov (United States)

    Słyk, Edyta; Roth, Roland; Bryk, Paweł

    2016-06-22

    We propose density functional theory for polymeric fluids in two dimensions. The approach is based on Wertheim's first order thermodynamic perturbation theory (TPT) and closely follows density functional theory for polymers proposed by Yu and Wu (2002 J. Chem. Phys. 117 2368). As a simple application we evaluate the density profiles of tangent hard-disk polymers at hard walls. The theoretical predictions are compared against the results of the Monte Carlo simulations. We find that for short chain lengths the theoretical density profiles are in an excellent agreement with the Monte Carlo data. The agreement is less satisfactory for longer chains. The performance of the theory can be improved by recasting the approach using the self-consistent field theory formalism. When the self-avoiding chain statistics is used, the theory yields a marked improvement in the low density limit. Further improvements for long chains could be reached by going beyond the first order of TPT.

  6. Invariant Measures with Bounded Variation Densities for Piecewise Area Preserving Maps

    CERN Document Server

    Zhang, Yiwei

    2011-01-01

    We investigate the properties of absolutely continuous invariant probability measures (ACIPs) for piecewise area preserving maps (PAPs) on $\\mathbb{R}^d$. This class of maps unifies piecewise isometries (PWIs) and piecewise hyperbolic maps where Lebesgue measure is locally preserved. In particular for PWIs, we use a functional approach to explore the relationship between topological transitivity and uniqueness of ACIPs, especially those measures with bounded variation densities. Our results "partially" answer one of the fundamental questions posed in \\cite{Goetz03} - determine all invariant non-atomic probability Borel measures in piecewise rotations. When reducing to interval exchange transformations (IETs), we demonstrate that for non-uniquely ergodic IETs with two or more ACIPs, these ACIPs have very irregular densities (namely of unbounded variation and discontinuous everywhere) and intermingle with each other.

  7. 40 CFR 63.5395 - How do I measure the density of a finish?

    Science.gov (United States)

    2010-07-01

    ... finish? 63.5395 Section 63.5395 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... National Emission Standards for Hazardous Air Pollutants for Leather Finishing Operations Testing and Initial Compliance Requirements § 63.5395 How do I measure the density of a finish? (a) To determine the...

  8. STEREOCHEMICAL ASPECTS OF HYDRATION OF CARBOHYDRATES IN AQUEOUS-SOLUTIONS .3. DENSITY AND ULTRASOUND MEASUREMENTS

    NARCIS (Netherlands)

    GALEMA, SA; HOILAND, H

    1991-01-01

    Density and ultrasound measurements have been performed in aqueous solutions of pentoses, hexoses, methylpyranosides, and disaccharides as a function of molality of carbohydrate (0-0.3 mol kg-1). Partial molar volumes, partial molar isentropic compressibilities, and hydration numbers have been calcu

  9. [Equipment for measuring the optical density of wide-format x-ray films].

    Science.gov (United States)

    Mikhaĭlov, V A; Ennenberg, M G

    1980-01-01

    For qualitative estimation of the dynamics of medical treatment in the patients with pulmonary diseases a device has been produced based on measuring the optical density of X-ray films. This device comprises the optical part of the microphotometer MF-2, a modified microscope stand, with its moving mechanism, electronic circuit with a logarithmic amplifier, control circuit and a double-coordinate-recorder.

  10. Measurement of the orbital angular momentum density of light by modal decomposition

    CSIR Research Space (South Africa)

    Schulze, C

    2013-07-01

    Full Text Available We demonstrate a versatile method for the measurement of the orbital angular momentum (OAM) density of an optical field. By performing a modal decomposition with digital holograms, we reconstruct the full optical field from a small set of single...

  11. Simultaneous Reconstructions of Absorption Density and Wave Speed with Photoacoustic Measurements

    CERN Document Server

    Kirsch, Andreas

    2011-01-01

    In this paper we propose an approach for \\emph{simultaneous} identification of the \\emph{absorption density} and the \\emph{speed of sound} by photoacoustic measurements. Experimentally our approach can be realized with sliced photoacoustic experiments. The mathematical model for such an experiment is developed and exact reconstruction formulas for both parameters are presented.

  12. STEREOCHEMICAL ASPECTS OF HYDRATION OF CARBOHYDRATES IN AQUEOUS-SOLUTIONS .3. DENSITY AND ULTRASOUND MEASUREMENTS

    NARCIS (Netherlands)

    GALEMA, SA; HOILAND, H

    1991-01-01

    Density and ultrasound measurements have been performed in aqueous solutions of pentoses, hexoses, methylpyranosides, and disaccharides as a function of molality of carbohydrate (0-0.3 mol kg-1). Partial molar volumes, partial molar isentropic compressibilities, and hydration numbers have been

  13. Measuring the Density of Different Materials by Using the Collimated Fast Neutron Beam

    Energy Technology Data Exchange (ETDEWEB)

    Sudac, D.; Nad, K.; Orlic, Z.; Obhodas, J. [Rudjer Boskovic Institute, Bijenicka c. 54, 10000 Zagreb (Croatia); Valkovic, V. [Rudjer Boskovic Institute, Zagreb (Croatia); Kvinticka 62, Zagreb (Croatia)

    2015-07-01

    It was demonstrated in the previous work that various threat materials could be detected inside the sea going cargo container by measuring the three variables, carbon and oxygen concentration and density of investigated material. Density was determined by measuring transmitted neutrons, which is not always practical in terms of setting up the instrument geometry. In order to enable more geometry flexibility, we have investigated the possibility of using the scattered neutrons in cargo material identification. For that purpose, the densities of different materials were measured depending on the position of neutron detectors and neutron generator with respect to the target position. One neutron detector was put above the target, one behind and one in front of the target, above the neutron generator. It was shown that all three positions of neutron detectors can be successfully used to measure the target density, but only if the detected neutrons are successfully discriminated from the gamma rays. Although the associated alpha particle technique/associate particle imaging (API) was used to discriminate the neutrons from the gamma rays, it is believed that the same results would be obtained by using the pulse shape discrimination method. In that way API technique can be avoided and the neutron generator which produces much higher beam intensity than 10{sup 8} n/s can be used. (authors)

  14. Interpretation of fast measurements of plasma potential, temperature and density in SOL of ASDEX Upgrade

    DEFF Research Database (Denmark)

    Horacek, J.; Adamek, J.; Müller, H.W.

    2010-01-01

    This paper focuses on interpretation of fast (1 µs) and local (2–4 mm) measurements of plasma density, potential and electron temperature in the edge plasma of tokamak ASDEX Upgrade. Steady-state radial profiles demonstrate the credibility of the ball-pen probe. We demonstrate that floating poten...

  15. Invariant Hermitian Operator and Density Operator for the Adiabatically Time-Dependent System

    Institute of Scientific and Technical Information of China (English)

    YAN Feng-Li; YANG Lin-Guang

    2001-01-01

    The density operator is approximately expressed as a function of the invariant Hermitian operator for the adiabatically time-dependent system. Using this method, the calculation of the density operator for the Heisenberg spin system in a weakly time-dependent magnetic field is exemplified. By virtue of the density operator, we obtain equilibrium.``

  16. Directional spectral emissivity measurement system

    Science.gov (United States)

    Halyo, Nesim (Inventor); Pandey, Dhirendra K. (Inventor)

    1992-01-01

    Apparatus and process for determining the emissivity of a test specimen including an integrated sphere having two concentric walls with a coolant circulating therebetween, and disposed within a chamber which may be under ambient, vacuum or inert gas conditions. A reference sample is disposed within the sphere with a monochromatic light source in optical alignment therewith. A pyrometer is in optical alignment with the test sample for obtaining continuous test sample temperature measurements during a test. An arcuate slit port is provided through the spaced concentric walls of the integrating sphere with a movable monochromatic light source extending through and movable along the arcuate slit port. A detector system extends through the integrating sphere for continuously detecting an integrated signal indicative of all radiation within its field of view, as a function of the emissivity of the test specimen at various temperatures and various angle position of the monochromatic light source. A furnace for heating the test sample to approximately 3000 K. and control mechanism for transferring the heated sample from the furnace to the test sample port in the integrating sphere is also contained within the chamber.

  17. Indicators System for Poverty Measurement

    Directory of Open Access Journals (Sweden)

    Constantin Mitrut

    2006-10-01

    Full Text Available Poverty represents a life aspect which is focusing the attention of both the macroeconomic analysis and the international comparisons. In order to measure the level being recorded by this phenomenon, there is a system of indicators which are used in order to underline, in a correlated manner, a number of aspects which are characterizing, quality and quantity wise, the evolution of the poverty in a specific country or, to a larger extent, through comparative surveys, at international level. Despite the fact that they are not the only instrument being used within the process of comparison of the stages of social and economic development at the international level, however the poverty indicators are providing a clear significance to the worked out surveys. In fact, the very purpose of the economic activity consists of increasing welfare and, as much as possible, at least reducing, if not eradicating, the poverty. The present work is broadly presenting the methodology as well as, both theoretical and practical, the way of computing the poverty, making a synthesis of the specific used indicators.

  18. A compact fast ionization gauge for in situ measurement of high-density neutral flow dynamics.

    Science.gov (United States)

    Weber, T E; Intrator, T P

    2014-04-01

    A compact ionization gauge has been developed to carry out in situ measurements of high density (10(20)-10(22) m(-3)) neutral gas flow dynamics with high temporal and spatial resolution. Key design aspects are discussed including gauge sensitivity and time response scaling with decreased probe dimensions, high-pressure operation, improved driver circuit bandwidth, and techniques for constructing a miniaturized probe head. Gas adsorption was discovered to significantly alter emission current and gauge sensitivity over timescales of several seconds. This effect must be taken into consideration when making time-resolved, high-density measurements. Over short timescales gauge response was predicted by scaling the sensitivity of a nominal Bayard-Alpert gauge to account for variations in probe dimensions and species-dependent ionization cross-section. Time-resolved neutral density profiles have been acquired in the Magnetized Shock Experiment at Los Alamos National Laboratory, providing data on the initial conditions of the ionization, plasmoid formation, and translation processes. It is shown that the desired density profiles can be achieved using a dynamic gas fill and that density can be scaled independently of the spatial profile.

  19. In Situ Measurements of the Size and Density of Titan Aerosol Analogues

    CERN Document Server

    Horst, Sarah M

    2013-01-01

    The organic haze produced from complex CH4/N2 chemistry in the atmosphere of Titan plays an important role in processes that occur in the atmosphere and on its surface. The haze particles act as condensation nuclei and are therefore involved in Titan's methane hydrological cycle. They also may behave like sediment on Titan's surface and participate in both fluvial and aeolian processes. Models that seek to understand these processes require information about the physical properties of the particles including their size and density. Although measurements obtained by Cassini-Huygens have placed constraints on the size of the haze particles, their densities remain unknown. We have conducted a series of Titan atmosphere simulation experiments and measured the size, number density, and particle density of Titan aerosol analogues, or tholins, for CH4 concentrations from 0.01% to 10% using two different energy sources, spark discharge and UV. We find that the densities currently in use by many Titan models are highe...

  20. Simultaneous measurement of electron temperature and density by a line pair method in the RFP plasma

    Science.gov (United States)

    Watanabe, Masayuki; Shimizu, S.; Ogawa, H.; Shinohara, T.

    2009-11-01

    A line-pair-method has been applied for a simultaneous measurement of the electron temperature and density in ATRAS RFP plasma. Three helium spectrum lines (668nm, 706nm, 728nm) were measured during the discharge at the same time and the electron temperature and density is estimated by using a Collision-Radiation model. To get the signal of the helium impunity line from the RFP discharge, the RFP plasma in the hydrogen gas with a few mixed helium gas was formed. In the typical ATRAS RFP discharge of the plasma current of 60kA, the electron temperature was approximately 50-150 eV and the electron density is the order of 10^18 m-3. During the discharge, the change of the temperature and density are mutually related and this correlation was the almost reverse phase. The periodically change of the temperature and density were also observed. This change synchronizes with a periodically increase of the averaged toroidal magnetic field, which is caused by the toroidal rotation of the increase of the toroidal magnetic field. This rotation, which is deeply related with dynamo effect, makes the plasma energy lose and particles also diffuse toward the plasma edge. As a result, the recycling of the particle and energy are occurred at the same time.

  1. Hole boring velocity measurements in near critical density plasmas by a CO2 laser pulse

    Science.gov (United States)

    Gong, Chao; Tochitsky, Sergei; Pigeon, Jeremy; Joshi, Chan

    2014-10-01

    Measurements of plasma dynamics during the interaction of a high-power laser pulse with an above critical density plasma is important for understanding absorption, transport and particle acceleration mechanisms. An important process that affects these mechanisms is hole boring occurring at the critical density because of the radiation pressure of the laser pulse. Yet, no systematic measurements of the hole boring velocity's (vhb) dependence on laser intensity (I) have been made. In this talk, we present experimental results of vhb in near critical density plasmas produced by CO2 laser as a function of I in the range of 1*1015 to 1.6*1016 W/cm2. A novel four frame Mach-Zehnder interferometer using a 1 ps, 532 nm probe laser pulse was developed to record the evolution of the plasma density profile and the motion of the near critical density layer. Using this diagnostic, we observed the motion of the steepened plasma profile due to the incident, time-structured CO2 laser pulse. Experimental results show the hole boring velocity increases from 0.004c to 0.007c as the laser intensity is increased from 1*1015 to 1.6*1016 W/cm2. This work is supported by DOE grant DE-FG02-92-ER40727, NSF grant PHY-0936266 at UCLA.

  2. First Solid Evidence for a Rocky Exoplanet - Mass and density of smallest exoplanet finally measured

    Science.gov (United States)

    2009-09-01

    The longest set of HARPS measurements ever made has firmly established the nature of the smallest and fastest-orbiting exoplanet known, CoRoT-7b, revealing its mass as five times that of Earth's. Combined with CoRoT-7b's known radius, which is less than twice that of our terrestrial home, this tells us that the exoplanet's density is quite similar to the Earth's, suggesting a solid, rocky world. The extensive dataset also reveals the presence of another so-called super-Earth in this alien solar system. "This is science at its thrilling and amazing best," says Didier Queloz, leader of the team that made the observations. "We did everything we could to learn what the object discovered by the CoRoT satellite looks like and we found a unique system." In February 2009, the discovery by the CoRoT satellite [1] of a small exoplanet around a rather unremarkable star named TYC 4799-1733-1 was announced one year after its detection and after several months of painstaking measurements with many telescopes on the ground, including several from ESO. The star, now known as CoRoT-7, is located towards the constellation of Monoceros (the Unicorn) at a distance of about 500 light-years. Slightly smaller and cooler than our Sun, CoRoT-7 is also thought to be younger, with an age of about 1.5 billion years. Every 20.4 hours, the planet eclipses a small fraction of the light of the star for a little over one hour by one part in 3000 [2]. This planet, designated CoRoT-7b, is only 2.5 million kilometres away from its host star, or 23 times closer than Mercury is to the Sun. It has a radius that is about 80% greater than the Earth's. The initial set of measurements, however, could not provide the mass of the exoplanet. Such a result requires extremely precise measurements of the velocity of the star, which is pulled a tiny amount by the gravitational tug of the orbiting exoplanet. The problem with CoRoT-7b is that these tiny signals are blurred by stellar activity in the form of

  3. An investigation of density measurement method for yarn-dyed woven fabrics based on dual-side fusion technique

    Science.gov (United States)

    Zhang, Rui; Xin, Binjie

    2016-08-01

    Yarn density is always considered as the fundamental structural parameter used for the quality evaluation of woven fabrics. The conventional yarn density measurement method is based on one-side analysis. In this paper, a novel density measurement method is developed for yarn-dyed woven fabrics based on a dual-side fusion technique. Firstly, a lab-used dual-side imaging system is established to acquire both face-side and back-side images of woven fabric and the affine transform is used for the alignment and fusion of the dual-side images. Then, the color images of the woven fabrics are transferred from the RGB to the CIE-Lab color space, and the intensity information of the image extracted from the L component is used for texture fusion and analysis. Subsequently, three image fusion methods are developed and utilized to merge the dual-side images: the weighted average method, wavelet transform method and Laplacian pyramid blending method. The fusion efficacy of each method is evaluated by three evaluation indicators and the best of them is selected to do the reconstruction of the complete fabric texture. Finally, the yarn density of the fused image is measured based on the fast Fourier transform, and the yarn alignment image could be reconstructed using the inverse fast Fourier transform. Our experimental results show that the accuracy of density measurement by using the proposed method is close to 99.44% compared with the traditional method and the robustness of this new proposed method is better than that of conventional analysis methods.

  4. Simultaneous measurement of magnetic and density fluctuations via cross-polarization scattering and Doppler backscattering on the DIII-D tokamak

    Science.gov (United States)

    Rhodes, T. L.; Barada, K.; Peebles, W. A.; Crocker, N. A.

    2016-11-01

    An upgraded cross-polarization scattering (CPS) system for the simultaneous measurement of internal magnetic fluctuations B ˜ and density fluctuations ñ is presented. The system has eight radial quadrature channels acquired simultaneously with an eight-channel Doppler backscattering system (measures density fluctuations ñ and flows). 3-D ray tracing calculations based on the GENRAY ray tracing code are used to illustrate the scattering and geometric considerations involved in the CPS implementation on DIII-D. A unique quasi-optical design and IF electronics system allow direct comparison of B ˜ and ñ during dynamic or transient plasma events (e.g., Edge Localized Modes or ELMs, L to H-mode transitions, etc.). The system design allows the interesting possibility of both magnetic-density ( B ˜ -ñ) fluctuation and magnetic-temperature ( B ˜ - T ˜ ) fluctuation cross-phase measurements suitable for detailed tests of turbulence simulations.

  5. Accuracy analysis of intrahepatic fat density measurements using dual-energy computed tomography: Validation using a test phantom.

    Science.gov (United States)

    Arai, Tomohiro; Misawa, Masaki; Arai, Miki; Shinozaki, Masafumi; Sakamoto, Kayo; Yajima, Yoshinobu; Nozaki, Yuichi; Tajima, Tsuyoshi; Sato, Masanori; Hinoshita, Fumihiko

    2017-01-01

    Currently, no standardized method for measuring intrahepatic fat density via conventional computed tomography (CT) exists. We aim to quantify intrahepatic fat density via material decomposition analysis using rapid kilovolt peak-switching dual-energy (RSDE) CT. Homogenized porcine liver and fat (lard) were mixed in various ratios to produce phantoms for fat density verification. The actual fat density was measured on the basis of the phantom volume and weight, and these measurements were used as reference densities. The fat and liver mass attenuation coefficients, which were used as the material basis pairs, were employed in the material decomposition analysis. Then, the measured fat density of each phantom was compared with the reference densities. For fat content differences exceeding 2%, the measured fat density for the phantoms became statistically significant (p densities and RSDE-measured fat densities was reasonably high (R > 0.9997); this indicates the validity of this analysis method. Intrahepatic fat density can be measured using the mass attenuation coefficients of fat and liver in a material decomposition analysis. Given the knowledge of the accuracy and the limitations found in this study, our method can quantitatively evaluate fat density.

  6. H I Column Densities, Metallicities, and Dust Extinction of Metal-Strong Damped Lya Systems

    CERN Document Server

    Kaplan, Kyle F; Herbert-Fort, Stephane; Ellison, Sara L; Dessauges-Zavadsky, Miroslava

    2010-01-01

    With the Blue Channel Spectrograph (BCS) on the MMT telescope, we have obtained spectra to the atmospheric cutoff of quasars previously known to show at least one absorption system at z>1.6 with very strong metal lines (candidate metal-strong damped Lya systems; cMSDLAs). The BCS/MMT spectra yield precise estimates of the HI column densities (NHI) of the systems through Voigt profile analysis of their Lya transitions. Nearly all of the cMSDLAs (41/43) satisfy the NHI criterion of DLAs, 10^20.3. As a population, these systems have systematically higher NHI values than DLAs chosen randomly from quasar sightlines. Combining our NHI measurements with previously measured metal column densities, we estimate metallicities for the MSDLAs. These systems have significantly higher values than randomly selected DLAs; at z~2, the MSDLAs show a median metallicity [M/H] ~ -0.67 that is 0.6dex higher than a corresponding control sample. This establishes MSDLAs as having amongst the most metal-rich gas in the high z universe....

  7. Measurement System and Calibration report

    DEFF Research Database (Denmark)

    Vesth, Allan; Kock, Carsten Weber

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...

  8. Measurement and Analysis of Density of Molten Ni-W Alloys

    Institute of Scientific and Technical Information of China (English)

    FANG Liang; XIAO Feng; TAO Zainan; MuKai Kusuhiro

    2005-01-01

    The density of molten Ni-W alloys was measured with a modified pycnometric method. It is found that the density of the molten Ni- W alloys decreases with temperature rising, but increases with the increase of tungsten concentration in the alloys. The molar volume of molten Ni- W binary alloys increases with the increase of temperature and tungsten concentration. The partial molar volume of tungsten in liquid Ni- W binary alloy has been calculated approximately as ( - 1.59+ 5.64 × 10-3 T) × 10-6m3 ·mol-1.

  9. Measurement of negative ion density in a pulsed multicusp negative ion source

    Energy Technology Data Exchange (ETDEWEB)

    Coonan, B.; Mellon, K.N.; Hopkins, M.B. (Dublin City University, Dublin (Ireland))

    1992-10-05

    The production of negative ion beams for use in neutral beam injection heating has become an important area of research in recent years. This paper discusses the negative ion densities measured in a pulsed multicusp volume ion source using photodetachment diagnostic technique. A pulse modulated negative ion source is being used as an alternative to the tandem source and an increase in negative ion extracted current has previously been observed by Hopkins and Mellon. Work with photodetachment quoted in this paper shows an increase in negative ion density during the post discharge similar to previous results obtained using an accelerator to extract the negative ions.

  10. Molar Volume Analysis of Molten Ni-Al-Co Alloy by Measuring the Density

    Institute of Scientific and Technical Information of China (English)

    XIAO Feng; FANG Liang; FU Yuechao; YANG Lingchuan

    2004-01-01

    The density of molten Ni-Al-Co alloys was measured in the temperature range of 1714~1873K using a modified pycnometric method, and the molar volume of molten alloys was analyzed. The density of molten Ni-Al-Co alloys was found to decrease with increasing temperature and Co concentration in alloys. The molar volume of molten Ni-Al-Co alloys increases with increasing Co concentration in alloys. The molar volume of molten Ni-Al-Co alloys shows a negative deviation from the linear molar volume.

  11. Preliminary measurements of velocity, density and total temperature fluctuations in compressible subsonic flow

    Science.gov (United States)

    Stainback, P. C.; Johnson, C. B.; Basnett, C. B.

    1983-01-01

    The heat transfer characteristics of a three-wire hot-wire probe operated with a constant temperature anemometer were investigated in the subsonic compressible flow regime. The sensitivity coefficients, with respect to velocity, density and total temperature, were measured and the results were used to calculate the velocity, density, and total temperature fluctuations in the test section of the Langley 0.3-m Transonic Cryogenic Tunnel (TCT). These results were extended to give estimates for fluctuations due to vorticity, sound, and entropy. In addition, attempts were made to determine the major source of disturbances in the 0.3-m TCT.

  12. Measurement for titanium density distribution on Ti:sapphire rods for high intensity pump source

    Energy Technology Data Exchange (ETDEWEB)

    Usami, Tsutomu; Nishimura, Akihiko; Sugiyama, Akira [Japan Atomic Energy Research Inst., Kizu, Kyoto (Japan). Kansai Research Establishment

    2001-10-01

    A Ti:sapphire rod of 190 mm length made by Czochralski (CZ) technique was used in the flashlamp pumped high intensity laser for Yb:glass chirped pulse amplification. In the absorption spectroscopy of the rod immersed in an index matching liquid of methylene iodide, heterogeneous Ti{sup 3+} density distribution was measured along the direction of length. It has been first clarified that the Ti:sapphire rod grown by the CZ technique has 20% difference of the Ti{sup 3+} density at the both ends. (author)

  13. Estimation of electrical conductivity distribution within the human head from magnetic flux density measurement.

    Science.gov (United States)

    Gao, Nuo; Zhu, S A; He, Bin

    2005-06-01

    We have developed a new algorithm for magnetic resonance electrical impedance tomography (MREIT), which uses only one component of the magnetic flux density to reconstruct the electrical conductivity distribution within the body. The radial basis function (RBF) network and simplex method are used in the present approach to estimate the conductivity distribution by minimizing the errors between the 'measured' and model-predicted magnetic flux densities. Computer simulations were conducted in a realistic-geometry head model to test the feasibility of the proposed approach. Single-variable and three-variable simulations were performed to estimate the brain-skull conductivity ratio and the conductivity values of the brain, skull and scalp layers. When SNR = 15 for magnetic flux density measurements with the target skull-to-brain conductivity ratio being 1/15, the relative error (RE) between the target and estimated conductivity was 0.0737 +/- 0.0746 in the single-variable simulations. In the three-variable simulations, the RE was 0.1676 +/- 0.0317. Effects of electrode position uncertainty were also assessed by computer simulations. The present promising results suggest the feasibility of estimating important conductivity values within the head from noninvasive magnetic flux density measurements.

  14. Measurements of the Electron Cloud Density in the PEP-II Low Energy Ring

    CERN Document Server

    Byrd, J; Sonnad, K; Caspers, Friedhelm; Kroyer, T; Krasnykh, A; Pivi, M

    2009-01-01

    Clouds of low energy electrons in the vacuum beam pipes of accelerators of positively charged particle beams present a serious limitation for operation of these machines at high currents. Because of the size of these accelerators, it is difficult to probe the low energy electron clouds over substantial lengths of the beam pipe. We have developed a novel technique to directly measure the electron cloud density via the phase shift induced in a TE wave that is independently excited and transmitted over a section of the accelerator. We infer the absolute phase shift with relatively high accuracy from the phase modulation of the transmission due to the modulation of the electron cloud density from a gap in the positively charged beam. We have used this technique for the first time to measure the average electron cloud density over a 50 m straight section in the positron ring of the PEP-II collider at the Stanford Linear Accelerator Center. We have also measured the variation of the density by using low field solen...

  15. Reliability of quantitative EEG (qEEG) measures and LORETA current source density at 30 days.

    Science.gov (United States)

    Cannon, Rex L; Baldwin, Debora R; Shaw, Tiffany L; Diloreto, Dominic J; Phillips, Sherman M; Scruggs, Annie M; Riehl, Timothy C

    2012-06-14

    There is a growing interest for using quantitative EEG and LORETA current source density in clinical and research settings. Importantly, if these indices are to be employed in clinical settings then the reliability of these measures is of great concern. Neuroguide (Applied Neurosciences) is sophisticated software developed for the analyses of power, and connectivity measures of the EEG as well as LORETA current source density. To date there are relatively few data evaluating topographical EEG reliability contrasts for all 19 channels and no studies have evaluated reliability for LORETA calculations. We obtained 4 min eyes-closed and eyes-opened EEG recordings at 30-day intervals. The EEG was analyzed in Neuroguide and FFT power, coherence and phase was computed for traditional frequency bands (delta, theta, alpha and beta) and LORETA current source density was calculated in 1 Hz increments and summed for total power in eight regions of interest (ROI). In order to obtain a robust measure of reliability we utilized a random effects model with an absolute agreement definition. The results show very good reproducibility for total absolute power and coherence. Phase shows lower reliability coefficients. LORETA current source density shows very good reliability with an average 0.81 for ECB and 0.82 for EOB. Similarly, the eight regions of interest show good to very good agreement across time. Implications for future directions and use of qEEG and LORETA in clinical populations are discussed.

  16. A fundamental measure density functional for fluid and crystal phases of the Asakura-Oosawa model

    Science.gov (United States)

    Mortazavifar, Mostafa; Oettel, Martin

    2016-06-01

    We investigate a density functional for the Asakura-Oosawa model of colloid-polymer mixtures, describing both fluid and crystal phases. It is derived by linearizing the two-component fundamental-measure hard sphere tensor functional in the second (polymer) component. We discuss the formulation of an effective density functional for colloids only. For small polymer-colloid size ratios the effective, polymer-induced potential between colloids is short-range attractive and of two-body form but we show that the effective density functional is not equivalent to standard mean-field approaches where attractions are taken into account by terms second order in the colloid density. We calculate numerically free energies and phase diagrams in good agreement with available simulations, furthermore we discuss the colloid and polymer distributions in the crystal and determine equilibrium vacancy concentrations. Numerical results reveal a fairly strong sensitivity to the specific type of underlying fundamental measure hard sphere functional which could aid further development of fundamental measure theory.

  17. Measurements of the Electron Cloud Density in the PEP-II Low Energy Ring

    Energy Technology Data Exchange (ETDEWEB)

    Byrd, John; De Santis, Stefano; Sonnad, Kiran; Caspers, Fritz; Kroyer, Tom; Krasnykh, Anatoly; Pivi, Mauro

    2008-06-01

    Clouds of low energy electronsin the vacuum beam pipes of accelerators of positively charged particle beams present a serious limitation for operation of these machines at high currents. Because of the size of these accelerators, it is difficult to probe the low energyelectron clouds over substantial lengths of the beam pipe. We have developed a novel technique to directly measure the electron cloud density via the phase shift induced in a TE wave that is independently excited and transmitted over a section of the accelerator. We infer the absolute phase shift with relatively high accuracy from the phase modulation of the transmission due to the modulation of the electron cloud density from a gap in the positively charged beam. We have used this technique for the first time to measure the average electron cloud density over a 50 m straight section in the positron ring of the PEP-II collider at the Stanford Linear Accelerator Center. We have also measured the variation of the density by using low field solenoid magnets to control the electrons.

  18. Design and theoretical analysis of a resonant sensor for liquid density measurement.

    Science.gov (United States)

    Zheng, Dezhi; Shi, Jiying; Fan, Shangchun

    2012-01-01

    In order to increase the accuracy of on-line liquid density measurements, a sensor equipped with a tuning fork as the resonant sensitive component is designed in this paper. It is a quasi-digital sensor with simple structure and high precision. The sensor is based on resonance theory and composed of a sensitive unit and a closed-loop control unit, where the sensitive unit consists of the actuator, the resonant tuning fork and the detector and the closed-loop control unit comprises precondition circuit, digital signal processing and control unit, analog-to-digital converter and digital-to-analog converter. An approximate parameters model of the tuning fork is established and the impact of liquid density, position of the tuning fork, temperature and structural parameters on the natural frequency of the tuning fork are also analyzed. On this basis, a tuning fork liquid density measurement sensor is developed. In addition, experimental testing on the sensor has been carried out on standard calibration facilities under constant 20 °C, and the sensor coefficients are calibrated. The experimental results show that the repeatability error is about 0.03% and the accuracy is about 0.4 kg/m(3). The results also confirm that the method to increase the accuracy of liquid density measurement is feasible.

  19. Particle filter with importance density function generated by updated system equation

    Institute of Scientific and Technical Information of China (English)

    左军毅; 贾颖娜; 张炜; 高全学

    2013-01-01

    The current measurement was exploited in a more efficient way. Firstly, the system equation was updated by introducing a correction term, which depends on the current measurement and can be obtained by running a suboptimal filter. Then, a new importance density function(IDF) was defined by the updated system equation. Particles drawn from the new IDF are more likely to be in the significant region of state space and the estimation accuracy can be improved. By using different suboptimal filter, different particle filters(PFs) can be developed in this framework. Extensions of this idea were also proposed by iteratively updating the system equation using particle filter itself, resulting in the iterated particle filter. Simulation results demonstrate the effectiveness of the proposed IDF.

  20. Mobile measurement system for wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Kildemoes Moeller, T.

    1997-06-01

    The aim of this project `Udviklingsafproevning af smaa moellevinger` has been to develop a mobile measurement system for wind turbines. The following report describes the measurement system. The project has been financed by the Danish Ministry of Energy. (au)

  1. The Effective Number Density of Galaxies for Weak Lensing Measurements in the LSST Project

    CERN Document Server

    Chang, C; Jain, B; Kahn, S M; Kirkby, D; Connolly, A; Krughoff, S; Peng, E; Peterson, J R

    2013-01-01

    Future weak lensing surveys potentially hold the highest statistical power for constraining cosmological parameters compared to other cosmological probes. The statistical power of a weak lensing survey is determined by the sky coverage, the inverse of the noise in shear measurements, and the galaxy number density. The combination of the latter two factors is often expressed in terms of $n_{\\rm eff}$ -- the "effective number density of galaxies used for weak lensing measurements". In this work, we estimate $n_{\\rm eff}$ for the Large Synoptic Survey Telescope (LSST) project, the most powerful ground-based lensing survey planned for the next two decades. We investigate how the following factors affect the resulting $n_{\\rm eff}$ of the survey with detailed simulations: (1) survey time, (2) shear measurement algorithm, (3) algorithm for combining multiple exposures, (4) inclusion of data from multiple filter bands, (5) redshift distribution of the galaxies, and (6) masking and blending. For the first time, we qu...

  2. Uncertainty Quantification for Nuclear Density Functional Theory and Information Content of New Measurements

    CERN Document Server

    McDonnell, J D; Higdon, D; Sarich, J; Wild, S M; Nazarewicz, W

    2015-01-01

    Statistical tools of uncertainty quantification can be used to assess the information content of measured observables with respect to present-day theoretical models; to estimate model errors and thereby improve predictive capability; to extrapolate beyond the regions reached by experiment; and to provide meaningful input to applications and planned measurements. To showcase new opportunities offered by such tools, we make a rigorous analysis of theoretical statistical uncertainties in nuclear density functional theory using Bayesian inference methods. By considering the recent mass measurements from the Canadian Penning Trap at Argonne National Laboratory, we demonstrate how the Bayesian analysis and a direct least-squares optimization, combined with high-performance computing, can be used to assess the information content of the new data with respect to a model based on the Skyrme energy density functional approach. Employing the posterior probability distribution computed with a Gaussian process emulator, w...

  3. AFM-porosimetry: density and pore volume measurements of particulate materials.

    Science.gov (United States)

    Sörensen, Malin H; Valle-Delgado, Juan J; Corkery, Robert W; Rutland, Mark W; Alberius, Peter C

    2008-06-01

    We introduced the novel technique of AFM-porosimetry and applied it to measure the total pore volume of porous particles with a spherical geometry. The methodology is based on using an atomic force microscope as a balance to measure masses of individual particles. Several particles within the same batch were measured, and by plotting particle mass versus particle volume, the bulk density of the sample can be extracted from the slope of the linear fit. The pore volume is then calculated from the densities of the bulk and matrix materials, respectively. In contrast to nitrogen sorption and mercury porosimetry, this method is capable of measuring the total pore volume regardless of pore size distribution and pore connectivity. In this study, three porous samples were investigated by AFM-porosimetry: one ordered mesoporous sample and two disordered foam structures. All samples were based on a matrix of amorphous silica templated by a block copolymer, Pluronic F127, swollen to various degrees with poly(propylene glycol). In addition, the density of silica spheres without a template was measured by two independent techniques: AFM and the Archimedes principle.

  4. The Applications of Measurement System for Crankshaft

    Institute of Scientific and Technical Information of China (English)

    DAI Shangping; GAO Li; GAO Kai

    2006-01-01

    This paper will introduce two types of multi-parameter co-measuring system and their application in the production. The first is crankshaft bent deformation measuring machine system. The second is the crankshaft pneumatic-electric measuring system. They have been used in final inspection procedure of automation line for crankshaft of automobie engine with good results, the structure principle and soft clash technological process of the measurement system are presented.

  5. The Effect of the Presence and Density of Shewanella oneidensis on Nuclear Magnetic Relaxation Measurements

    Science.gov (United States)

    Keating, K.; Halsey, J.

    2011-12-01

    A recent interest in the use of non-invasive geophysical methods to detect the presence of and measure the growth of microbes in the subsurface has arisen due to the potential use of such methods to monitor the progress of bioremediation. Previous research to this end has focused on electrical measurements, such as complex resistivity, which are sensitive to the presence of microbes but can be difficult to interpret. Nuclear magnetic resonance (NMR), an emerging near-surface geophysical method, is sensitive to the presence and physiochemical environment of hydrogen. Typically, NMR measurements in geophysics are used to detect hydrogen in water or hydrocarbons and to determine its pore environment; however, NMR imaging measurements have shown that NMR can also detect hydrogen in microbes. Geophysical NMR measurements thus have the potential to directly detect microbes in geologic material or indirectly detect the way in which the presence of microbes alters the physical and chemical properties of a water-saturated geologic material. This laboratory-scale study was designed to explore the effect of the presence and density of microbes on NMR relaxation measurements. Measurements were collected on microbial slurries and microbes in porous media both during microbial growth and on samples with known microbial density. Shewanella oneidensis was used as a representative environmental microbe in this study. The research shows that low field NMR measurements are sensitive to the presence and density of microbes and provides fundamental information required to determine if low-field NMR measurements can be used to monitor microbial growth during bioremediation.

  6. Measurements of density field in a swirling flame by 2D spontaneous Raman scattering

    Science.gov (United States)

    Sharaborin, D. K.; Dulin, V. M.; Lobasov, A. S.; Markovich, D. M.

    2016-10-01

    This paper presents an evaluation of the density distribution in swirling turbulent premixed flames. The measurement principle is based on registration of spontaneous Raman scattering, when the reacting gas flow is illuminated by a laser sheet. Evaluation of 1D and 2D distributions of density and temperature were performed in a laminar Bunsen flame as a test case for validation of experimental technique. Time-averaged 2D images of the scattering during rovibronic transitions of nitrogen molecules were captured in turbulent premixed low-swirl and high-swirl (Re = 5000) propane-air flames in a wide range of equivalence ratio. The obtained density fields are useful for better understanding of heat and mass transfer in swirl-stabilized turbulent flames and for validation of CFD results.

  7. Measurement of local current density of all-vanadium redox flow batteries

    Science.gov (United States)

    Hsieh, Wen-Yen; Leu, Chih-Hsing; Wu, Chun-Hsing; Chen, Yong-Song

    2014-12-01

    This article presents a preliminary study of the measurement of local current density in all-vanadium redox flow batteries. Two batteries are designed and manufactured in this study, and the experimental results are compared. In the first cell, the current collector is divided into 25 segments, and the flow field plate is not segmented, whereas in the other cell, the flow field plate is segmented. The effects of the electrolyte flow rate on the battery efficiencies and the local current density variation are investigated. The experimental results show that the current density near the outlet significantly decreases when the discharge capacity approaches zero. In addition, the battery has a larger discharge depth at a higher electrolyte flow rate.

  8. Investigation of zonal flows by using the collective scattering measurement of density fluctuations

    Science.gov (United States)

    Shen, H. G.; Yu, Y.; Lan, T.; Li, Y. D.; Liu, A. D.; Xie, J. L.; Liu, W. D.; Yu, C. X.; Zhang, W. Y.; Ti, A.; Li, J. G.

    2015-09-01

    The poloidal {{E}r}× {{B}\\text{T}} rotation velocities in the core plasma region are studied using the instantaneous frequency method (IFM) with the density fluctuations measured by the CO2 laser collective scattering diagnostics on the HT-7 tokamak. A coherent mode is observed in the fluctuations of poloidal velocities with the mode frequency from 10 to 20 kHz. It is identified as geodesic acoustic mode (GAM) zonal flow with poloidal symmetry (m = 0) and its mode frequency coinciding with the theoretical expected GAM frequency. The nonlinear interactions are investigated by applying the envelope analysis on the density fluctuations. The results confirm that the envelope modulation in the high frequency density fluctuations only comes from the shearing by GAM. The comparison between IFM and envelope analysis is also discussed.

  9. Differential heating: A versatile method for thermal conductivity measurements in high-energy-density matter

    Energy Technology Data Exchange (ETDEWEB)

    Ping, Y.; Fernandez-Panella, A.; Correa, A.; Shepherd, R.; Landen, O.; London, R. A.; Sterne, P. A.; Whitley, H. D.; Fratanduono, D.; Collins, G. W. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Sio, H. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Boehly, T. R. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States)

    2015-09-15

    We propose a method for thermal conductivity measurements of high energy density matter based on differential heating. A temperature gradient is created either by surface heating of one material or at an interface between two materials by different energy deposition. The subsequent heat conduction across the temperature gradient is observed by various time-resolved probing techniques. Conceptual designs of such measurements using laser heating, proton heating, and x-ray heating are presented. The sensitivity of the measurements to thermal conductivity is confirmed by simulations.

  10. Spectral discrete probability density function of measured wind turbine noise in the far field.

    Science.gov (United States)

    Ashtiani, Payam; Denison, Adelaide

    2015-01-01

    Of interest is the spectral character of wind turbine noise at typical residential set-back distances. In this paper, a spectral statistical analysis has been applied to immission measurements conducted at three locations. This method provides discrete probability density functions for the Turbine ONLY component of the measured noise. This analysis is completed for one-third octave sound levels, at integer wind speeds, and is compared to existing metrics for measuring acoustic comfort as well as previous discussions on low-frequency noise sources.

  11. Spectral discrete probability density function of measured wind turbine noise in the far field

    Directory of Open Access Journals (Sweden)

    Payam eAshtiani

    2015-04-01

    Full Text Available Of interest is the spectral character of wind turbine noise at typical residential set-back distances. In this paper a spectral statistical analysis has been applied to immission measurements conducted at three locations. This method provides discrete probability density functions for the Turbine ONLY component of the measured noise. This analysis is completed for 1/3rd Octave sound levels, at integer wind speeds, and is compared to existing metrics for measuring acoustic comfort as well as previous discussions on low frequency noise sources.

  12. Systematic measurements of opacity dependence on temperature, density, and atomic number at stellar interior conditions

    Science.gov (United States)

    Bailey, James; Nagayama, T.; Loisel, G. P.; Rochau, G. A.; Blancard, C.; Colgan, J.; Cosse, Ph.; Faussurier, G.; Fontes, C. J.; Golovkin, I.; Hansen, S. B.; Iglesias, C. A.; Kilcrease, D. P.; Macfarlane, J. J.; Mancini, R. C.; Nahar, S. N.; Orban, C.; Pradhan, A. K.; Sherrill, M.; Wilson, B. G.; Pain, J. C.; Gilleron, F.

    2016-10-01

    Model predictions for iron opacity are notably different from measurements performed at conditions similar to the boundary between the solar radiation and convection zone. New measurements at the Sandia Z facility with chromium, iron, and nickel are providing a systematic study of how opacity changes with temperature, density, and atomic number. These measurements help further evaluate possibilities for experiment errors and help constrain hypotheses for opacity model refinements. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under contract DE-AC04-94AL85000.

  13. A Multi-Point Sensor Based on Optical Fiber for the Measurement of Electrolyte Density in Lead-Acid Batteries

    Science.gov (United States)

    Cao-Paz, Ana M.; Marcos-Acevedo, Jorge; del Río-Vázquez, Alfredo; Martínez-Peñalver, Carlos; Lago-Ferreiro, Alfonso; Nogueiras-Meléndez, Andrés A.; Doval-Gandoy, Jesús

    2010-01-01

    This article describes a multi-point optical fiber-based sensor for the measurement of electrolyte density in lead-acid batteries. It is known that the battery charging process creates stratification, due to the different densities of sulphuric acid and water. In order to study this process, density measurements should be obtained at different depths. The sensor we describe in this paper, unlike traditional sensors, consists of several measurement points, allowing density measurements at different depths inside the battery. The obtained set of measurements helps in determining the charge (SoC) and state of health (SoH) of the battery. PMID:22319262

  14. Reproducibility of the cutoff probe for the measurement of electron density

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. W.; Oh, W. Y. [Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 305-701 (Korea, Republic of); You, S. J., E-mail: sjyou@cnu.ac.kr [Department of Physics, Chungnam National University, Daejeon 305-701 (Korea, Republic of); Kwon, J. H.; You, K. H.; Seo, B. H.; Kim, J. H., E-mail: jhkim86@kriss.re.kr [Center for Vacuum Technology, Korea Research Institute of Standards and Science, Daejeon 305-306 (Korea, Republic of); Yoon, J.-S. [Plasma Technology Research Center, National Fusion Research Institute, Gunsan 573-540 (Korea, Republic of)

    2016-06-15

    Since a plasma processing control based on plasma diagnostics attracted considerable attention in industry, the reproducibility of the diagnostics using in this application has become a great interest. Because the cutoff probe is one of the potential candidates for this application, knowing the reproducibility of the cutoff probe measurement becomes quit important in the cutoff probe application research. To test the reproducibility of the cutoff probe measurement, in this paper, a comparative study among the different cutoff probe measurements was performed. The comparative study revealed remarkable result: the cutoff probe has a great reproducibility for the electron density measurement, i.e., there are little differences among measurements by different probes made by different experimenters. The discussion including the reason for the result was addressed via this paper by using a basic measurement principle of cutoff probe and a comparative experiment with Langmuir probe.

  15. Measurement and modeling of neutral, radical, and ion densities in H2-N2-Ar plasmas

    Science.gov (United States)

    Sode, M.; Jacob, W.; Schwarz-Selinger, T.; Kersten, H.

    2015-02-01

    A comprehensive experimental investigation of absolute ion and neutral species densities in an inductively coupled H2-N2-Ar plasma was carried out. Additionally, the radical and ion densities were calculated using a zero-dimensional rate equation model. The H2-N2-Ar plasma was studied at a pressure of 1.5 Pa and an rf power of 200 W. The N2 partial pressure fraction was varied between fN2=0 % and 56% by a simultaneous reduction of the H2 partial pressure fraction. The Ar partial pressure fraction was held constant at about 1%. NH3 was found to be produced almost exclusively on the surfaces of the chamber wall. NH3 contributes up to 12% to the background gas. To calculate the radical densities with the rate equation model, it is necessary to know the corresponding wall loss times twrad of the radicals. twrad was determined by the temporal decay of radical densities in the afterglow with ionization threshold mass spectrometry during pulsed operation and based on these experimental data the absolute densities of the radical species were calculated and compared to measurement results. Ion densities were determined using a plasma monitor (mass and energy resolved mass spectrometer). H3+ is the dominant ion in the range of 0.0 ≤fN2reasonably well. The ion chemistry, i.e., the production and loss processes of the ions and radicals, is discussed in detail. The main features, i.e., the qualitative abundance of the ion species and the ion density dependence on the N2 partial pressure fraction, are well reproduced by the model.

  16. Sourceless formation evaluation. An LWD solution providing density and neutron measurements without the use of radioisotopes

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, R.; Reichel, N. [Schlumberger, Sungai Buloh (Malaysia)

    2013-08-01

    For many years the industry has been searching for a way to eliminate the logistical difficulties and risk associated with deployment of radioisotopes for formation evaluation. The traditional gamma-gamma density (GGD) measurement uses the scattering of 662-keV gamma rays from a 137Cs radioisotopic source, with a 30.17-year half-life, to determine formation density. The traditional neutron measurement uses an Am-Be source emitting neutrons with an energy around 4 MeV, with a half-life of 432 years. Both these radioisotopic sources pose health, security, and environmental risks. Pulsed-neutron generators have been used in the industry for several decades in wireline tools and more recently in logging-while-drilling tools. These generators produce 14-MeV neutrons, many of which interact with the nuclei in the formation. Elastic collisions allow a neutron porosity measurement to be derived, which has been available to the industry since 2005. Inelastic interactions are typically followed by the emission of a variety of high-energy gamma rays. Similar to the case of the GGD measurement, the transport and attenuation of these gamma rays is a strong function of the formation density. However, the gamma-ray source is now distributed over a volume within the formation, where gamma rays have been induced by neutron interactions and the source can no longer be considered to be a point as in the case of a radioisotopic source. In addition, the extent of the induced source region depends on the transport of the fast neutrons from the source to the point of gamma-ray production. Even though the physics is more complex, it is possible to measure the formation density if the fast neutron transport is taken into account when deriving the density answer. This paper briefly reviews the physics underlying the sourceless neutron porosity and recently introduced neutron-gamma density (SNGD) measurement, demonstrates how they can be used in traditional workflows and illustrates their

  17. Measures of Autonomic Nervous System

    Science.gov (United States)

    2011-04-01

    Resiliency Model (TRM)* X* X* Trauma and Tension Releasing Exercises (TRE) Yoga (Asana) Postures X X Breathing Practices...MBSR) Yoga Nidra (iRest) X X *Study currently in progress utilizing these measures 7...measuring oxygen saturation of blood. The Doppler radar cardiopulmonary remote sensing unit and the wearable reflectance pulse oximeter have the benefit

  18. Quantum cascade laser-based measurement of metal alkylamide density during atomic layer deposition.

    Science.gov (United States)

    Maslar, James E; Kimes, William A; Sperling, Brent A

    2012-03-01

    An in situ gas-phase diagnostic for the metal alkylamide compound tetrakis(ethylmethylamido) hafnium (TEMAH), Hf[N(C(2)H(5))(CH(3))](4), was demonstrated. This diagnostic is based on direct absorption measurement of TEMAH vapor using an external cavity quantum cascade laser emitting at 979 cm(-1), coinciding with the most intense TEMAH absorption in the mid-infrared spectral region, and employing 50 kHz amplitude modulation with synchronous detection. Measurements were performed in a single-pass configuration in a research-grade atomic layer deposition (ALD) chamber. To examine the detection limit of this technique for use as a TEMAH delivery monitor, this technique was demonstrated in the absence of any other deposition reactants or products, and to examine the selectivity of this technique in the presence of deposition products that potentially interfere with detection of TEMAH vapor, it was demonstrated during ALD of hafnium oxide using TEMAH and water. This technique successfully detected TEMAH at molecular densities present during simulated industrial ALD conditions. During hafnium oxide ALD using TEMAH and water, absorbance from gas-phase reaction products did not interfere with TEMAH measurements while absorption by reaction products deposited on the optical windows did interfere, although interfering absorption by deposited reaction products corresponded to only ≈4% of the total derived TEMAH density. With short measurement times and appropriate signal averaging, estimated TEMAH minimum detectable densities as low as ≈2 × 10(12) molecules/cm(3) could be obtained. While this technique was demonstrated specifically for TEMAH delivery and hafnium oxide ALD using TEMAH and water, it should be readily applicable to other metal alkylamide compounds and associated metal oxide and nitride deposition chemistries, assuming similar metal alkylamide molar absorptivity and molecular density in the measurement chamber.

  19. Measurement of induced magnetic flux density using injection current nonlinear encoding (ICNE) in MREIT.

    Science.gov (United States)

    Park, Chunjae; Lee, Byung Il; Kwon, Ohin; Woo, Eung Je

    2007-02-01

    Magnetic resonance electrical impedance tomography (MREIT) measures induced magnetic flux densities subject to externally injected currents in order to visualize conductivity distributions inside an electrically conducting object. Injection currents induce magnetic flux densities that appear in phase parts of acquired MR image data. In the conventional current injection method, we inject currents during the time segment between the end of the first RF pulse and the beginning of the reading gradient in order to ensure the gradient linearity. Noting that longer current injections can accumulate more phase changes, we propose a new pulse sequence called injection current nonlinear encoding (ICNE) where the duration of the injection current pulse is extended until the end of the reading gradient. Since the current injection during the reading gradient disturbs the gradient linearity, we first analyze the MR signal produced by the ICNE pulse sequence and suggest a novel algorithm to extract the induced magnetic flux density from the acquired MR signal. Numerical simulations and phantom experiments show that the new method is clearly advantageous in terms of the reduced noise level in measured magnetic flux density data. The amount of noise reduction depends on the choice of the data acquisition time and it was about 24% when we used a prolonged data acquisition time of 10.8 ms. The ICNE method will enhance the clinical applicability of the MREIT technique when it is combined with an appropriate phase artefact minimization method.

  20. {sup 10}B concentration evaluation in autoradiography images by optical density measurements

    Energy Technology Data Exchange (ETDEWEB)

    Portu, A., E-mail: portu@cnea.gov.ar [Centro Atomico Constituyentes (CAC), Comision Nacional de Energia Atomica (CNEA), Av. Gral. Paz 1499, AC: B1650KNA, San Martin, Buenos Aires (Argentina)] [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Rivadavia 1917, AC: C1033AAJ, Ciudad Autonoma de Buenos Aires (Argentina); Saint Martin, G., E-mail: gisaint@cnea.gov.ar [Centro Atomico Constituyentes (CAC), Comision Nacional de Energia Atomica (CNEA), Av. Gral. Paz 1499, AC: B1650KNA, San Martin, Buenos Aires (Argentina); Brandizzi, D., E-mail: brandizzi@cnea.gov.ar [Centro Atomico Constituyentes (CAC), Comision Nacional de Energia Atomica (CNEA), Av. Gral. Paz 1499, AC: B1650KNA, San Martin, Buenos Aires (Argentina)] [Laboratorio de Microespectrofotometria (LANAIS-MEF), CONICET-CNEA (Argentina); Bernaola, O.A., E-mail: bernaola@cnea.gov.ar [Centro Atomico Constituyentes (CAC), Comision Nacional de Energia Atomica (CNEA), Av. Gral. Paz 1499, AC: B1650KNA, San Martin, Buenos Aires (Argentina)

    2011-12-15

    The quantification and analysis of the tracks forming the autoradiography image of a tissue section is essential for the measurement of particle emitter concentration and distribution (e.g. {sup 10}B) in the sample. Conventional counting techniques cannot be used when track density is high because of track overlapping. A densitometry supported by image analysis method suitable for these cases has been developed. Optical density measurements obtained for boron solutions of known concentrations showed a linear behavior in the range of concentrations under consideration. - Highlights: Black-Right-Pointing-Pointer A nuclear tracks quantification method was developed applying optical densitometry supported by image analysis. Black-Right-Pointing-Pointer It will provide information about {sup 10}B distribution in samples whose autoradiographies present high density of tracks. Black-Right-Pointing-Pointer A calibration curve for optical density versus boron concentration was constructed and applied to the analysis of boron-doped silicon wafers. Black-Right-Pointing-Pointer Results were compared with those from an individual counting technique, obtaining a good agreement.

  1. Merlon-type density waves in a compartmentalized conveyor system

    Science.gov (United States)

    Kanellopoulos, G.; van derWeele, K.

    2016-09-01

    Multi-particle flow through a cyclic array of K connected compartments with a preferential direction is known to be able to organize itself in the form of density waves [Kanellopoulos, Van der Meer, and Van der Weele, Phys. Rev. E 92, 022205 (2015)]. In this brief note we focus on the intriguing shape these waves take when K is even, in which case they travel through alternatingly dense and diluted compartments. We call them "merlon waves", since the sequence of high and low densities is reminiscent of the merlons and crenels on the battlements of medieval castles.

  2. Measurements of electron cloud density in the CERN Super Proton Synchrotron with the microwave transmission method

    Directory of Open Access Journals (Sweden)

    S. Federmann

    2011-01-01

    Full Text Available The electron cloud effect can pose severe performance limitations in high-energy particle accelerators as the CERN Super Proton Synchrotron (SPS. Mitigation techniques such as vacuum chamber thin film coatings with low secondary electron yields (SEY<1.3 aim to reduce or even suppress this effect. The microwave transmission method, developed and first applied in 2003 at the SPS, measures the integrated electron cloud density over a long section of an accelerator. This paper summarizes the theory and measurement principle and describes the new SPS microwave transmission setup used to study the electron cloud mitigation of amorphous carbon coated SPS dipole vacuum chambers. Comparative results of carbon coated and bare stainless steel dipole vacuum chambers are given for the beam with nominal LHC 25 ns bunch-to-bunch spacing in the SPS and the electron cloud density is derived.

  3. Double-cavity radiometer for high-flux density solar radiation measurements.

    Science.gov (United States)

    Parretta, A; Antonini, A; Armani, M; Nenna, G; Flaminio, G; Pellegrino, M

    2007-04-20

    A radiometric method has been developed, suitable for both total power and flux density profile measurement of concentrated solar radiation. The high-flux density radiation is collected by a first optical cavity, integrated, and driven to a second optical cavity, where, attenuated, it is measured by a conventional radiometer operating under a stationary irradiation regime. The attenuation factor is regulated by properly selecting the aperture areas in the two cavities. The radiometer has been calibrated by a pulsed solar simulator at concentration levels of hundreds of suns. An optical model and a ray-tracing study have also been developed and validated, by which the potentialities of the radiometer have been largely explored.

  4. Electron Cloud Density Measurements in Accelerator Beam-pipe Using Resonant Microwave Excitation

    CERN Document Server

    Sikora, John P

    2013-01-01

    An accelerator beam can generate low energy electrons in the beam-pipe, generally called electron cloud, that can produce instabilities in a positively charged beam. One method of measuring the electron cloud density is by coupling microwaves into and out of the beam-pipe and observing the response of the microwaves to the presence of the electron cloud. This paper describes a technique in which the beam-pipe is resonantly excited with microwaves and the electron cloud density calculated from the change that it produces in the resonant frequency of the beam-pipe. The resonant technique has the advantage that measurements can be localized to sections of beam-pipe that are a meter or less in length, as well as greatly improving the signal to noise ratio.

  5. Cloud liquid water, mean droplet radius, and number density measurements using a Raman lidar

    Energy Technology Data Exchange (ETDEWEB)

    Whiteman, David N. [Laser Remote Sensing Branch, NASA Goddard Space Flight Center, Greenbelt, Maryland (United States); Melfi, S. Harvey [Department of Physics, University of Maryland, Baltimore County, Baltimore (United States)

    1999-12-27

    A new technique for measuring cloud liquid water, mean droplet radius, and droplet number density is outlined. The technique is based on simultaneously measuring Raman and Mie scattering from cloud liquid droplets using a Raman lidar. Laboratory experiments on liquid microspheres have shown that the intensity of Raman scattering is proportional to the amount of liquid present in the spheres. This fact is used as a constraint on calculated Mie intensity assuming a gamma function particle size distribution. The resulting retrieval technique is shown to give stable solutions with no false minima. It is tested using Raman lidar data where the liquid water signal was seen as an enhancement to the water vapor signal. The general relationship of retrieved average radius and number density is consistent with traditional cloud physics models. Sensitivity to the assumed maximum cloud liquid water amount and the water vapor mixing ratio calibration are tested. Improvements to the technique are suggested. (c) 1999 American Geophysical Union.

  6. Plasma Density Measurements in Cable Gun Experiments with a Sensitive He-Ne Interferometer

    Institute of Scientific and Technical Information of China (English)

    CHEN Lin; HE An; JIANG Wei; XU Min; WU Shoudong; LI Ye

    2007-01-01

    A time-resolved sensitive He-Ne laser interferometer without complicated active stabilization was built up and applied to low-density plasma measurements. A precision of about 0.2° in phase measurements was achieved with a minimum line-integrated plasma density as low as 8.3×l013 cm-2. With this interferometer, the characteristics of the plasma generated by a cable plasma gun was investigated systematically. The reproducibility, spatial and temporal distributions and the averaged injection velocity of the plasma are presented. In addition, the interaction of the plasma flow with a conductor was studied by placing a metal plate in the downstream of the cable gun.

  7. Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

    Science.gov (United States)

    Torrisi, Giuseppe; Mascali, David; Neri, Lorenzo; Leonardi, Ornella; Sorbello, Gino; Celona, Luigi; Castro, Giuseppe; Agnello, Riccardo; Caruso, Antonio; Passarello, Santi; Longhitano, Alberto; Isernia, Tommaso; Gammino, Santo

    2016-02-01

    The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 1011-1013 cm-3 and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called "frequency sweep" method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

  8. Apparatus for accurate density measurements of fluids based on a magnetic suspension balance

    Science.gov (United States)

    Gong, Maoqiong; Li, Huiya; Guo, Hao; Dong, Xueqiang; Wu, J. F.

    2012-06-01

    A new apparatus for accurate pressure, density and temperature (p, ρ, T) measurements over wide ranges of (p, ρ, T) (90 K to 290 K; 0 MPa to 3 MPa; 0 kg/m3 to 2000 kg/m3) is described. This apparatus is based on a magnetic suspension balance which applies the Archimedes' buoyancy principle. In order to verify the new apparatus, comprehensive (p, ρ, T) measurements on pure nitrogen were carried out. The maximum relative standard uncertainty is 0.09% in density. The maximum standard uncertainty in temperature is 5 mK, and that in pressure is 250 Pa for 1.5 MPa and 390 Pa for 3MPa full scale range respectively. The experimental data were compared with selected literature data and good agreements were found.

  9. Cloud Liquid Water, Mean Droplet Radius and Number Density Measurements Using a Raman Lidar

    Science.gov (United States)

    Whiteman, David N.; Melfi, S. Harvey

    1999-01-01

    A new technique for measuring cloud liquid water, mean droplet radius and droplet number density is outlined. The technique is based on simultaneously measuring Raman and Mie scattering from cloud liquid droplets using a Raman lidar. Laboratory experiments on liquid micro-spheres have shown that the intensity of Raman scattering is proportional to the amount of liquid present in the spheres. This fact is used as a constraint on calculated Mie intensity assuming a gamma function particle size distribution. The resulting retrieval technique is shown to give stable solutions with no false minima. It is tested using Raman lidar data where the liquid water signal was seen as an enhancement to the water vapor signal. The general relationship of retrieved average radius and number density is consistent with traditional cloud physics models. Sensitivity to the assumed maximum cloud liquid water amount and the water vapor mixing ratio calibration are tested. Improvements to the technique are suggested.

  10. Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Torrisi, Giuseppe [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); University Mediterranea of Reggio Calabria, Reggio Calabria (Italy); Mascali, David; Neri, Lorenzo; Leonardi, Ornella; Celona, Luigi; Castro, Giuseppe; Agnello, Riccardo; Caruso, Antonio; Passarello, Santi; Longhitano, Alberto; Gammino, Santo [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); Sorbello, Gino [INFN - Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); University of Catania, Catania, Italy and INFN-LNS, Catania (Italy); Isernia, Tommaso [University Mediterranea of Reggio Calabria, Reggio Calabria (Italy)

    2016-02-15

    The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

  11. Measurement of axial neutral density profiles in a microwave discharge ion thruster by laser absorption spectroscopy with optical fiber probes.

    Science.gov (United States)

    Tsukizaki, Ryudo; Koizumi, Hiroyuki; Nishiyama, Kazutaka; Kuninaka, Hitoshi

    2011-12-01

    In order to reveal the physical processes taking place within the "μ10" microwave discharge ion thruster, internal plasma diagnosis is indispensable. However, the ability of metallic probes to access microwave plasmas biased at a high voltage is limited from the standpoints of the disturbance created in the electric field and electrical isolation. In this study, the axial density profiles of excited neutral xenon were successfully measured under ion beam acceleration by using a novel laser absorption spectroscopy system. The target of the measurement was metastable Xe I 5p(5)((2)P(0) (3/2))6s[3/2](0) (2) which absorbed a wavelength of 823.16 nm. Signals from laser absorption spectroscopy that swept a single-mode optical fiber probe along the line of sight were differentiated and converted into axial number densities of the metastable neutral particles in the plasma source. These measurements revealed a 10(18) m(-3) order of metastable neutral particles situated in the waveguide, which caused two different modes during the operation of the μ10 thruster. This paper reports a novel spectroscopic measurement system with axial resolution for microwave plasma sources utilizing optical fiber probes.

  12. Rocket-borne measurements of electron temperature and density with the Electron Retarding Potential Analyzer instrument

    Science.gov (United States)

    Cohen, I. J.; Widholm, M.; Lessard, M. R.; Riley, P.; Heavisides, J.; Moen, J. I.; Clausen, L. B. N.; Bekkeng, T. A.

    2016-07-01

    Determining electron temperature in the ionosphere is a fundamentally important measurement for space science. Obtaining measurements of electron temperatures at high altitudes (>700 km) is difficult because of limitations on ground-based radar and classic spacecraft instrumentation. In light of these limitations, the rocket-borne Electron Retarding Potential Analyzer (ERPA) was developed to allow for accurate in situ measurement of ionospheric electron temperature with a simple and low-resource instrument. The compact ERPA, a traditional retarding potential analyzer with multiple baffle collimators, allows for a straightforward calculation of electron temperature. Since its first mission in 2004, it has amassed significant flight heritage and obtained data used in multiple studies investigating a myriad of phenomena related to magnetosphere-ionosphere coupling. In addition to highlighting the scientific contributions of the ERPA instrument, this paper outlines its theory and operation, the methodology used to obtain electron temperature measurements, and a comparative study suggesting that the ERPA can also provide electron density measurements.

  13. Scattered and (n,2n) neutrons as a measure of areal density in ICF capsules

    CERN Document Server

    Wilson, D C; Disdier, L; Houry, M; Bourgade, J L; Murphy, T J

    2002-01-01

    The fraction of low-energy neutrons created from 14 MeV neutrons by elastic scattering and (n,2n) reactions on D and T has been proposed as a measure of the areal density (radial integral of density) of ICF targets. In simple situations the fraction of neutrons between 9.4 (the upper energy of T+T neutrons) and 13 MeV (below the Doppler broadened 14.1 MeV peak) is proportional to the at the time of neutron production. This ratio does not depend upon the temperature of the fuel, as does the number of reaction-in-flight neutrons. The ratio of neutrons elastically scattered at a specific energy (e.g. 13 MeV) to the total number of neutrons can be measured along different lines of sight. The ratio of two perpendicular measurements provides a quantitative measure of asymmetry. A detector can be placed inside the target chamber to measure these low-energy neutrons. If it is close enough to the target that measurements are made before the 14 MeV neutrons reach the chamber wall, gamma rays can be a negligible back...

  14. Multiple-capillary measurement of RBC speed, flux, and density with optical coherence tomography.

    Science.gov (United States)

    Lee, Jonghwan; Wu, Weicheng; Lesage, Frederic; Boas, David A

    2013-11-01

    As capillaries exhibit heterogeneous and fluctuating dynamics even during baseline, a technique measuring red blood cell (RBC) speed and flux over many capillaries at the same time is needed. Here, we report that optical coherence tomography can capture individual RBC passage simultaneously over many capillaries located at different depths. Further, we demonstrate the ability to quantify RBC speed, flux, and linear density. This technique will provide a means to monitor microvascular flow dynamics over many capillaries at different depths at the same time.

  15. Low-density lipoprotein analysis in microchip capillary electrophoresis systems

    NARCIS (Netherlands)

    Ceriotti, Laura; Shibata, Takayuki; Folmer, Britta; Weiller, Bruce H.; Roberts, Matthew A.; De Rooij, Nico F.; Verpoorte, Elisabeth

    2002-01-01

    Due to the mounting evidence for altered lipoprotein and cholesterol-lipoprotein content in several disease states, there has been an increasing interest in analytical methods for lipoprotein profiling for diagnosis. The separation of low- and high-density lipoproteins (LDL and HDL, respectively)

  16. The functional response to prey density in an acarine system

    NARCIS (Netherlands)

    Fransz, H.G.

    1974-01-01

    Predacious mites are considered to be important natural enemies of phytophagous mites. Their efficiency in the natural control of prey populations depends on the relationships of the number of prey killed per predator per time unit and the oviposition rate on the one hand and prey density on the

  17. Introduction to control system performance measurements

    CERN Document Server

    Garner, K C

    1968-01-01

    Introduction to Control System Performance Measurements presents the methods of dynamic measurements, specifically as they apply to control system and component testing. This book provides an introduction to the concepts of statistical measurement methods.Organized into nine chapters, this book begins with an overview of the applications of automatic control systems that pervade almost every area of activity ranging from servomechanisms to electrical power distribution networks. This text then discusses the common measurement transducer functions. Other chapters consider the basic wave

  18. Design and expected performance of a fast neutron attenuation probe for light element density measurements

    Science.gov (United States)

    Sweany, M.; Marleau, P.

    2016-10-01

    We present the design and expected performance of a proof-of-concept 32 channel material identification system. Our system is based on the energy-dependent attenuation of fast neutrons for four elements: hydrogen, carbon, nitrogen and oxygen. We describe a new approach to obtaining a broad range of neutron energies to probe a sample, as well as our technique for reconstructing the molar densities within a sample. The system's performance as a function of time-of-flight energy resolution is explored using a Geant4-based Monte Carlo. Our results indicate that, with the expected detector response of our system, we will be able to determine the molar density of all four elements to within a 20-30% accuracy in a two hour scan time. In many cases this error is systematically low, thus the ratio between elements is more accurate. This degree of accuracy is enough to distinguish, for example, a sample of water from a sample of pure hydrogen peroxide: the ratio of oxygen to hydrogen is reconstructed to within 8±0.5% of the true value. Finally, with future algorithm development that accounts for backgrounds caused by scattering within the sample itself, the accuracy of molar densities, not ratios, may improve to the 5-10% level for a two hour scan time.

  19. A Noncontact Measurement Technique for the Density and Thermal Expansion Coefficient of Solid and Liquid Materials

    Science.gov (United States)

    Chung, Sang K.; Thiessen, David B.; Rhim, Won-Kyu

    1996-01-01

    A noncontact measurement technique for the density and the thermal expansion refractory materials in their molten as well as solid phases is presented. This technique is based on the video image processing of a levitated sample. Experiments were performed using the high-temperature electrostatic levitator (HTESL) at the Jet Propulsion Laboratory in which 2-3 mm diameter samples can be levitated, melted, and radiatively cooled in a vacuum. Due to the axisymmetric nature of the molten samples when levitated in the HTESL, a rather simple digital image analysis can be employed to accurately measure the volumetric change as a function of temperature. Density and the thermal expansion coefficient measurements were made on a pure nickel sample to test the accuracy of the technique in the temperature range of 1045-1565 C. The result for the liquid phase density can be expressed by p = 8.848 + (6.730 x 10(exp -4)) x T (degC) g/cu cm within 0.8% accuracy, and the corresponding thermal expansion coefficient can be expressed by Beta=(9.419 x 10(exp -5)) - (7.165 x 10(exp -9) x T (degC)/K within 0.2% accuracy.

  20. Understanding compressible turbulence in the solar wind with multipoint density measurements derived from spacecraft potential

    Science.gov (United States)

    Roberts, Owen

    2016-04-01

    Measurements of spacecraft potential can often be used to derive the electron number density with higher time resolution than is typically available with plasma instruments. On board the Cluster spacecraft the potential is measured with the Electric Fields and Waves instrument (EFW) which consists of four booms in the spin plane of the spacecraft. Consequently the potential measurement is affected by spin and wake effects. This makes the study of frequencies larger than the spin frequency challenging. To overcome these caveats a statistical model of the potential is obtained as a function of the angle the spacecraft is facing. When this variation is known it can be removed from the potential data, resulting in a much more accurate determination of the electron density and a cleaner power spectrum. Spikes at harmonics of the spin frequency can be removed without the need to use a notch filter on the time series. The treated data can then be used as an input to the k-filtering technique, which has previously been applied to the incompressible components of the magnetic field. This allows determination of the three dimensional power distribution in wave space as well as the wavevectors and plasma frame frequencies. Results for the compressible component (using electron density and magnitude of the magnetic field as inputs) and the incompressible component (three components of the magnetic field) will be compared.

  1. Sensing fluid viscosity and density through mechanical impedance measurement using a whisker transducer

    Science.gov (United States)

    Ju, Feng; Ling, Shih-Fu

    2013-05-01

    This paper presents a new technique for fluid viscosity and density sensing through measuring the mechanical impedance of the fluid load applied on a sphere. A piezoelectric whisker transducer (WT) is proposed which acts simultaneously as both the actuator to excite the sphere tip to oscillate in the fluid and the sensor to measure the force, velocity and mechanical impedance. The relationship between mechanical impedance of the fluid load and electrical impedance of the WT is derived based on a transduction matrix model which characterizes the electro-mechanical transduction process of the WT in both directions. The mechanical impedance is further related to the fluid viscosity and density using a theoretical model. The establishment of this fluid-mechanical-electrical relationship allows the WT to extract the fluid viscosity and density conveniently and accurately just from its electrical impedance. Experimental studies are carried out to calibrate the WT and test its performance using glycerol-water mixtures. It is concluded that the WT is capable of providing results comparable to those of standard viscometers within a wide measurement range due to its low working frequency and large vibration amplitude. Its unique self-actuation-and-sensing feature makes it a suitable solution for online fluid sensing.

  2. Low Temperature Emissivity Measurement System

    Directory of Open Access Journals (Sweden)

    Jignesh A. Patel

    2014-05-01

    Full Text Available The emissivity of a material is the relative ability of its surface to emit energy by radiation. It is the ratio of energy radiated by a particular material to energy radiated by a black body at the same temperature. Knowledge about the low temperature emissivity of materials and coatings can be essential to the design of fusion cryoplants and in the thermal modeling for space satellite missions. The emittance of materials at cryogenics temperatures often cannot be predicted from room temperature data, but for computing radiative loads and infrared backgrounds this cryogenic data is often required. Measurement of the cryogenic emissivity of a highly reflective surface is a significant challenge: little thermal power is radiated from the sample, and the background radiation. However some researchers have measured emissivity at various low temperature ranges. Present work reports, the various emissivity measurement setup and their considerations.

  3. Density distribution of {sup 14}Be from reaction cross-section measurements

    Energy Technology Data Exchange (ETDEWEB)

    Moriguchi, T. [Institute of Physics, University of Tsukuba, Tsukuba, Ibaraki 305-8571 (Japan); Ozawa, A., E-mail: ozawa@tac.tsukuba.ac.jp [Institute of Physics, University of Tsukuba, Tsukuba, Ibaraki 305-8571 (Japan); Ishimoto, S. [High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801 (Japan); Abe, Y. [Institute of Physics, University of Tsukuba, Tsukuba, Ibaraki 305-8571 (Japan); Fukuda, M. [Department of Physics, Osaka University, Osaka 560-0043 (Japan); Hachiuma, I. [Department of Physics, Saitama University, Saitama 338-8570 (Japan); Ishibashi, Y.; Ito, Y. [Institute of Physics, University of Tsukuba, Tsukuba, Ibaraki 305-8571 (Japan); Kuboki, T. [Department of Physics, Saitama University, Saitama 338-8570 (Japan); Lantz, M. [RIKEN Nishina Center, Wako, Saitama 351-0198 (Japan); Nagae, D. [Institute of Physics, University of Tsukuba, Tsukuba, Ibaraki 305-8571 (Japan); Namihira, K. [Department of Physics, Saitama University, Saitama 338-8570 (Japan); Nishimura, D. [Department of Physics, Osaka University, Osaka 560-0043 (Japan); Ohtsubo, T. [Department of Physics, Niigata University, Niigata 950-2181 (Japan); Ooishi, H. [Institute of Physics, University of Tsukuba, Tsukuba, Ibaraki 305-8571 (Japan); Suda, T. [RIKEN Nishina Center, Wako, Saitama 351-0198 (Japan); Suzuki, H. [Institute of Physics, University of Tsukuba, Tsukuba, Ibaraki 305-8571 (Japan); Suzuki, T. [Department of Physics, Saitama University, Saitama 338-8570 (Japan); Takechi, M.; Tanaka, K. [RIKEN Nishina Center, Wako, Saitama 351-0198 (Japan); and others

    2014-09-15

    We measured the reaction cross sections of the two-neutron halo nucleus {sup 14}Be with proton and carbon targets at about 41 and 76 MeV/nucleon. Based on a Glauber model calculation, we deduced the matter density distribution of {sup 14}Be in which previously measured interaction cross sections at relativistic energies were also included. An s-wave dominance in {sup 14}Be has been confirmed, although the halo tail of {sup 14}Be is not distributed as much as that of {sup 11}Li. Significant mixing of the p-wave in addition to the s- and d-wave is also suggested.

  4. Density functional theory for molecular and periodic systems using density fitting and continuous fast multipole method: Analytical gradients.

    Science.gov (United States)

    Łazarski, Roman; Burow, Asbjörn Manfred; Grajciar, Lukáš; Sierka, Marek

    2016-10-30

    A full implementation of analytical energy gradients for molecular and periodic systems is reported in the TURBOMOLE program package within the framework of Kohn-Sham density functional theory using Gaussian-type orbitals as basis functions. Its key component is a combination of density fitting (DF) approximation and continuous fast multipole method (CFMM) that allows for an efficient calculation of the Coulomb energy gradient. For exchange-correlation part the hierarchical numerical integration scheme (Burow and Sierka, Journal of Chemical Theory and Computation 2011, 7, 3097) is extended to energy gradients. Computational efficiency and asymptotic O(N) scaling behavior of the implementation is demonstrated for various molecular and periodic model systems, with the largest unit cell of hematite containing 640 atoms and 19,072 basis functions. The overall computational effort of energy gradient is comparable to that of the Kohn-Sham matrix formation. © 2016 Wiley Periodicals, Inc.

  5. A laser-induced fluorescence measurement technique for obtaining neutral hydrogen densities in plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Yao, X.Z.; Yang, T.F.; Chang-Diaz, F.R. [Plasma Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)

    1995-09-01

    The resonance fluorescence of neutral hydrogen illuminated by {ital H}{sub {alpha}} radiation has been used as a technique for the spatially and temporally resolved density measurements of neutral hydrogen in high temperature plasmas, such as in the tokamak and magnetic mirror plasma fusion devices. The fluorescence signal, usually very weak and buried in the background of stray laser light and {ital H}{sub {alpha}} emission, is very difficult to extract and its measurements are inaccurate. This paper discusses the improvement of the signal extraction using two optical path laser-induced fluorescence (LIF) methods. One optical path carries the fluorescence signal and the background (the stray laser light and {ital H}{sub {alpha}} emission), whereas the other path carries only the background signal. By combining these two signals, a clean fluorescence signal can be isolated by subtracting out the background using a differential amplifier. The measurement is obtained instantaneously from these two signals which are taken simultaneously in one pulse rather than being extracted from two separate spectra taken in two sequential pulses (double pulses). This method, therefore, makes a significant improvement on the double pulse technique in terms of the accuracy of the measurement and the time resolution. Using this LIF technique the measurement of the neutral density profile in the exhaust of a tandem mirror plasma propulsion device is obtained and presented. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  6. Uncertainty quantification for nuclear density functional theory and information content of new measurements

    Energy Technology Data Exchange (ETDEWEB)

    McDonnell, J. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Schunck, N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Higdon, D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sarich, J. [Argonne National Lab. (ANL), Argonne, IL (United States); Wild, S. M. [Argonne National Lab. (ANL), Argonne, IL (United States); Nazarewicz, W. [Michigan State Univ., East Lansing, MI (United States); Oak Ridge National Lab., Oak Ridge, TN (United States); Univ. of Warsaw, Warsaw (Poland)

    2015-03-24

    Statistical tools of uncertainty quantification can be used to assess the information content of measured observables with respect to present-day theoretical models, to estimate model errors and thereby improve predictive capability, to extrapolate beyond the regions reached by experiment, and to provide meaningful input to applications and planned measurements. To showcase new opportunities offered by such tools, we make a rigorous analysis of theoretical statistical uncertainties in nuclear density functional theory using Bayesian inference methods. By considering the recent mass measurements from the Canadian Penning Trap at Argonne National Laboratory, we demonstrate how the Bayesian analysis and a direct least-squares optimization, combined with high-performance computing, can be used to assess the information content of the new data with respect to a model based on the Skyrme energy density functional approach. Employing the posterior probability distribution computed with a Gaussian process emulator, we apply the Bayesian framework to propagate theoretical statistical uncertainties in predictions of nuclear masses, two-neutron dripline, and fission barriers. Overall, we find that the new mass measurements do not impose a constraint that is strong enough to lead to significant changes in the model parameters. As a result, the example discussed in this study sets the stage for quantifying and maximizing the impact of new measurements with respect to current modeling and guiding future experimental efforts, thus enhancing the experiment-theory cycle in the scientific method.

  7. Breathing detection with a portable impedance measurement system: first measurements.

    Science.gov (United States)

    Cordes, Axel; Foussier, Jerome; Leonhardt, Steffen

    2009-01-01

    For monitoring the health status of individuals, detection of breathing and heart activity is important. From an electrical point of view, it is known that breathing and heart activity change the electrical impedance distribution in the human body over the time due to ventilation (high impedance) and blood shifts (low impedance). Thus, it is possible to detect both important vital parameters by measuring the impedance of the thorax or the region around lung and heart. For some measurement scenarios it is also essential to detect these parameters contactless. For instance, monitoring bus drivers health could help to limit accidents, but directly connected systems limit the drivers free moving space. One measurement technology for measuring the impedance changes in the chest without cables is the magnetic impedance tomography (MIT). This article describes a portable measurement system we developed for this scenario that allows to measure breathing contactless. Furthermore, first measurements with five volunteers were performed and analyzed.

  8. Label-Free Density Measurements of Radial Peripapillary Capillaries in the Human Retina.

    Directory of Open Access Journals (Sweden)

    Paula K Yu

    Full Text Available Radial peripapillary capillaries (RPCs comprise a unique network of capillary beds within the retinal nerve fibre layer (RNFL and play a critical role in satisfying the nutritional requirements of retinal ganglion cell (RGC axons. Understanding the topographical and morphological characteristics of these networks through in vivo techniques may improve our understanding about the role of RPCs in RGC axonal health and disease. This study utilizes a novel, non-invasive and label-free optical imaging technique, speckle variance optical coherence tomography (svOCT, for quantitatively studying RPC networks in the human retina. Six different retinal eccentricities from 16 healthy eyes were imaged using svOCT. The same eccentricities were histologically imaged in 9 healthy donor eyes with a confocal scanning laser microscope. Donor eyes were subject to perfusion-based labeling techniques prior to retinal dissection, flat mounting and visualization with the microscope. Capillary density and diameter measurements from each eccentricity in svOCT and histological images were compared. Data from svOCT images were also analysed to determine if there was a correlation between RNFL thickness and RPC density. The results are as follows: (1 The morphological characteristics of RPC networks on svOCT images are comparable to histological images; (2 With the exception of the nasal peripapillary region, there were no significant differences in RPC density measurements between svOCT and histological images; (3 Capillary diameter measurements were significantly greater in svOCT images compared to histology; (4 There is a positive correlation between RPC density and RNFL thickness. The findings in this study suggest that svOCT is a reliable modality for analyzing RPC networks in the human retina. It may therefore be a valuable tool for aiding our understanding about vasculogenic mechanisms that are involved in RGC axonopathies. Further work is required to explore the

  9. Label-Free Density Measurements of Radial Peripapillary Capillaries in the Human Retina.

    Science.gov (United States)

    Yu, Paula K; Balaratnasingam, Chandrakumar; Xu, Jing; Morgan, William H; Mammo, Zaid; Han, Sherry; Mackenzie, Paul; Merkur, Andrew; Kirker, Andrew; Albiani, David; Sarunic, Marinko V; Yu, Dao-Yi

    2015-01-01

    Radial peripapillary capillaries (RPCs) comprise a unique network of capillary beds within the retinal nerve fibre layer (RNFL) and play a critical role in satisfying the nutritional requirements of retinal ganglion cell (RGC) axons. Understanding the topographical and morphological characteristics of these networks through in vivo techniques may improve our understanding about the role of RPCs in RGC axonal health and disease. This study utilizes a novel, non-invasive and label-free optical imaging technique, speckle variance optical coherence tomography (svOCT), for quantitatively studying RPC networks in the human retina. Six different retinal eccentricities from 16 healthy eyes were imaged using svOCT. The same eccentricities were histologically imaged in 9 healthy donor eyes with a confocal scanning laser microscope. Donor eyes were subject to perfusion-based labeling techniques prior to retinal dissection, flat mounting and visualization with the microscope. Capillary density and diameter measurements from each eccentricity in svOCT and histological images were compared. Data from svOCT images were also analysed to determine if there was a correlation between RNFL thickness and RPC density. The results are as follows: (1) The morphological characteristics of RPC networks on svOCT images are comparable to histological images; (2) With the exception of the nasal peripapillary region, there were no significant differences in RPC density measurements between svOCT and histological images; (3) Capillary diameter measurements were significantly greater in svOCT images compared to histology; (4) There is a positive correlation between RPC density and RNFL thickness. The findings in this study suggest that svOCT is a reliable modality for analyzing RPC networks in the human retina. It may therefore be a valuable tool for aiding our understanding about vasculogenic mechanisms that are involved in RGC axonopathies. Further work is required to explore the reason for

  10. Vertical variation of particle speed and flux density in aeolian saltation: Measurement and modeling

    Science.gov (United States)

    Rasmussen, Keld R.; SøRensen, Michael

    2008-06-01

    Particle dynamics in aeolian saltation has been studied in a boundary layer wind tunnel above beds composed of quartz grains having diameters of either 242 μm or 320 μm. The cross section of the tunnel is 600 mm × 900 mm, and its thick boundary layer allows precise estimation of the fluid friction speed. Saltation is modeled using a numerical saltation model, and predicted grain speeds agree fairly well with experimental results obtained from laser-Doppler anemometry. The use of laser-Doppler anemometry to study aeolian saltation is thoroughly discussed and some pitfalls are identified. At 80 mm height the ratio between air speed and grain speed is about 1.1 and from there it increases toward the bed so that at 5 mm it is about 2.0. All grain speed profiles converge toward a common value of about 1 m/s at 2-3 mm height. Moreover, the estimated launch velocity distributions depend only very weakly on the friction speed in contrast to what has often been assumed in the literature. Flux density profiles measured with a laser-Doppler appear to be similar to most other density profiles measured with vertical array compartment traps; that is, two exponential segments will fit data between heights from a few millimeters to 100-200 mm. The experimental flux density profiles are found to agree well with model predictions. Generally, validation rates are low from 30 to 50% except at the highest level of 80 mm, where they approach 80%. When flux density profiles based on the validated data are used to estimate the total mass transport rate results are in fair agreement with measured transport rates except for conditions near threshold where as much as 50% difference is observed.

  11. Laboratory measurements of soot particle density change due to water uptake.

    Science.gov (United States)

    Crosbie, E.

    2015-12-01

    Black carbon containing soot particles are an important aerosol subclass owing to their light-absorbing properties. Furthermore, soot particles present challenges with regard to characterization and modeling of their microphysical, chemical, and optical properties, because of their inherent non-spherical, fractal morphology. Aggregation/coagulation of soot adds to the complexity of the particle morphology, while co-emitted organic compounds affect the chemical composition both during emission and though aging, which causes partitioning of secondary organic aerosol. Measurements of soot particles from vehicular and jet engine exhaust plumes have shown that the effective density can vary over a broad range (0.3-1.8 gm-3) and is affected by the fuel burn characteristics (fuel type, fuel equivalence ratio, combustion temperature), the particle size, and the extent of the aggregation. The action of organic coatings and the uptake of particle water, through hygroscopic growth, can cause a dramatic change in the morphology of soot. Restructuring of the fractal morphology into a more compact form has the effect of increasing the effective particle density, thus reducing the particle size, with important implications for the optical and hygroscopic properties. We present measurements of size-resolved particle density from laboratory generated fresh soot particles, under a range of operating conditions. We first filter by particle mass using an aerosol particle mass (APM) centrifugal analyzer and then subject the sample to a pre-humidification cycle in order to initiate particle restructuring. Finally, the sample is dried and the mobility size distribution is measured using a scanning mobility particle sizer (SMPS). A range of particle masses is scanned to determine the density as a function of size and, for each mass set point, a range of relative humidity settings are scanned to determine the extent of restructuring. We discuss the findings in relation to atmospherically

  12. 3D-Laser-Scanning Technique Applied to Bulk Density Measurements of Apollo Lunar Samples

    Science.gov (United States)

    Macke, R. J.; Kent, J. J.; Kiefer, W. S.; Britt, D. T.

    2015-01-01

    In order to better interpret gravimetric data from orbiters such as GRAIL and LRO to understand the subsurface composition and structure of the lunar crust, it is import to have a reliable database of the density and porosity of lunar materials. To this end, we have been surveying these physical properties in both lunar meteorites and Apollo lunar samples. To measure porosity, both grain density and bulk density are required. For bulk density, our group has historically utilized sub-mm bead immersion techniques extensively, though several factors have made this technique problematic for our work with Apollo samples. Samples allocated for measurement are often smaller than optimal for the technique, leading to large error bars. Also, for some samples we were required to use pure alumina beads instead of our usual glass beads. The alumina beads were subject to undesirable static effects, producing unreliable results. Other investigators have tested the use of 3d laser scanners on meteorites for measuring bulk volumes. Early work, though promising, was plagued with difficulties including poor response on dark or reflective surfaces, difficulty reproducing sharp edges, and large processing time for producing shape models. Due to progress in technology, however, laser scanners have improved considerably in recent years. We tested this technique on 27 lunar samples in the Apollo collection using a scanner at NASA Johnson Space Center. We found it to be reliable and more precise than beads, with the added benefit that it involves no direct contact with the sample, enabling the study of particularly friable samples for which bead immersion is not possible

  13. Interpretation of very low frequency electromagnetic measurements in terms of normalized current density over variable topography

    Science.gov (United States)

    Singh, Anand; Sharma, S. P.

    2016-10-01

    A 2D inversion approach is developed to interpret VLF electromagnetic measurement recorded over variable topography. To depict the variable topography accurately, an octree mesh discretization is incorporated. Subsurface structure is modeled in terms of apparent current density distribution and compared with the inversion results for actual resistivity distribution obtained using numerical techniques. The study demonstrates that the results obtained using both approaches (current density and resistivity distribution) are comparable, but due to analytical expression, current density imaging is faster. The conjugate gradient method is used to reduce the computation time and storage space when solving the matrix equations, resulting in feasible and practical imaging inversion of VLF data. The preconditioned matrix, which is determined by the distances between the blocks and observation points, has an important function in improving the resolution. In case of flat earth, preconditioned conjugate gradient inversion of data results in images that are comparable to those obtained using resistivity inversion. We also test whether topography variation in the order of skin depth is significant to incorporate topography in the modeling. The example of a topographical field VLF data inversion shows the efficacy of the presented approach to appraise the subsurface structure in terms of current density.

  14. Solar wind density structure at 1 AU and comparison to Doppler scintillation measurements

    Science.gov (United States)

    Huddleston, D. E.; Woo, R.; Neugebauer, M.

    1996-07-01

    Results of a survey of solar wind density fluctuations in different flow types observed by ISEE-3 at 1 AU are presented and compared with Doppler scintillation measurements. We consider coronal hole, plasma sheet, interstream, CME and sheath interaction region flow types. For the quasi-stationary solar wind, densities (N) and density fluctuation levels (ΔN) are low in coronal hole flow, and high in the plasma sheet containing the heliospheric current sheet (HCS). The highest fluctuation levels are found in the sheath compression regions between CMEs and associated forward shocks. The streamer structure around the HCS broadens and erodes with distance from the Sun, and the broadened Doppler scintillation signature at 1 AU is in good qualitative agreement with ISEE-3 superposed epoch analysis. The observed asymmetry about the HCS is an expected result of solar wind dynamic evolution. A greater contrast between flow types is seen in ΔN levels rather than in N itself. Doppler scintillation responds to ΔN and thus provides a sensitive means of detecting interplanetary disturbances. However, we find that ΔN/N is not constant in the solar wind, and thus enhanced scintillation cannot unambiguously imply enhanced density.

  15. A stepwedge-based method for measuring breast density: observer variability and comparison with human reading

    Science.gov (United States)

    Diffey, Jenny; Berks, Michael; Hufton, Alan; Chung, Camilla; Verow, Rosanne; Morrison, Joanna; Wilson, Mary; Boggis, Caroline; Morris, Julie; Maxwell, Anthony; Astley, Susan

    2010-04-01

    Breast density is positively linked to the risk of developing breast cancer. We have developed a semi-automated, stepwedge-based method that has been applied to the mammograms of 1,289 women in the UK breast screening programme to measure breast density by volume and area. 116 images were analysed by three independent operators to assess inter-observer variability; 24 of these were analysed on 10 separate occasions by the same operator to determine intra-observer variability. 168 separate images were analysed using the stepwedge method and by two radiologists who independently estimated percentage breast density by area. There was little intra-observer variability in the stepwedge method (average coefficients of variation 3.49% - 5.73%). There were significant differences in the volumes of glandular tissue obtained by the three operators. This was attributed to variations in the operators' definition of the breast edge. For fatty and dense breasts, there was good correlation between breast density assessed by the stepwedge method and the radiologists. This was also observed between radiologists, despite significant inter-observer variation. Based on analysis of thresholds used in the stepwedge method, radiologists' definition of a dense pixel is one in which the percentage of glandular tissue is between 10 and 20% of the total thickness of tissue.

  16. Density of liquid NiCoAlCr quarternary alloys measured by modified sessile drop method

    Institute of Scientific and Technical Information of China (English)

    FANG Liang; ZHANG Shu-fang; XIAO Feng; YANG Ling-chuan; DONG Jian-xin; CAO Chun-lan; TAO Zai-nan; K. MUKAI

    2006-01-01

    The densities of liquid NiCoAlCr quaternary alloys with a fixed molar ratio of Ni to Co to Al (x(Ni)-x(Co)-x(Al)≈73-12-15) which is close to the average value of the commercial Ni-based superalloys TMS75, INCO713, CM247LC and CMSX-4, and the mass fraction of chromium changes from 0 to 9% were measured by a modified sessile drop method. It is found that with increasing temperature and chromium concentration in the alloys, the densities of the liquid NiCoAlCr quaternary alloys decrease, whereas the molar volume of the liquid NiCoAlCr quaternary alloys increases. And the liquid densities of NiCoAlCr quaternary alloys calculated from the partial molar volumes of nickel, cobalt, aluminum and chromium in the corresponding Ni-bases binary alloys are in good agreement with the experimental ones, i.e. within the error tolerance range the densities of the liquid Ni-based multi-component alloys can be predicted from the partial volumes of elements in Ni-based binary alloys in liquid state. The molar volume of liquid NiCoAlCr binary alloy shows a negative deviation from the ideal linear mixing and the deviation changes small with the increase of chromium concentration at the same temperature.

  17. First results from plasma density measurements in the FTU tokamak by means of a two-frequency pulsed time-of-flight refractometer

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, V. G.; Malyshev, A. Yu.; Markov, V. K.; Petrov, A. A. [Troitsk Institute for Innovation and Fusion Research (Russian Federation); Avino, F.; Angelis, R. de; Tudisco, O. [ENEA-UT Fusione Centro Ricerche Frascati (Italy)

    2012-04-15

    A pulsed time-of-flight refractometer was developed and tested to determine the mean plasma density in the T-11M tokamak by measuring the propagation time of nanosecond microwave pulses in plasma. Later, it was also proposed to use such an instrument to measure and control the mean plasma density in the ITER tokamak by probing the plasma with an extraordinary wave, the electric field of which is perpendicular to the magnetic field in plasma, in the transparency window at frequencies of 50-100 GHz. To avoid the effect of the density profile shape on the measurement results in the nonlinear mode of refractometer operation (near the cutoff), a system operating at two different probing frequencies was developed and tested. Such a system provides two values of the time delay, which can be used to estimate the peaking factor of the density distribution {alpha} and correctly determine the linear density Left-Pointing-Angle-Bracket Nl Right-Pointing-Angle-Bracket , regardless of the density profile (assuming a smooth density profile of the form of N({rho}) = N(0)(1 - {rho}{sup 2}){sup {alpha}}, where N(0) is the central plasma density and {rho} = r/a is the normalized plasma radius). The first experiments on density measurements in the FTU tokamak performed with this refractometer are described, and results from these experiments are presented. The formation of a thin dense plasma layer in the zone of a strong magnetic field (the so-called MARFE layer) at a relatively low (for FTU) plasma density of {approx}6 Multiplication-Sign 10{sup 19} m{sup -3} was detected. The thickness of this layer, determined from the refractometry data, agrees well with the data obtained using a digital camera.

  18. Neutralino relic density from ILC measurements in the CP-violating MSSM

    Science.gov (United States)

    Bélanger, G.; Kittel, O.; Kraml, S.; Martyn, H.-U.; Pukhov, A.

    2008-07-01

    We discuss ILC measurements for a specific MSSM scenario with CP phases, where the lightest neutralino is a good candidate for dark matter, annihilating efficiently through t-channel exchange of light staus. These prospective (CP-even) ILC measurements are then used to fit the underlying model parameters. A collider prediction of the relic density of the neutralino from this fit gives 0.116<Ωh2<0.19 at 95% C.L. CP-odd observables, while being a direct signal of CP violation, do not help in further constraining Ωh2. The interplay with (in)direct detection of dark matter and with measurements of electric dipole moments is also discussed. Finally we comment on collider measurements at higher energies for refining the prediction of Ωh2.

  19. A new method to measure galaxy bias by combining the density and weak lensing fields

    Science.gov (United States)

    Pujol, Arnau; Chang, Chihway; Gaztañaga, Enrique; Amara, Adam; Refregier, Alexandre; Bacon, David J.; Carretero, Jorge; Castander, Francisco J.; Crocce, Martin; Fosalba, Pablo; Manera, Marc; Vikram, Vinu

    2016-10-01

    We present a new method to measure redshift-dependent galaxy bias by combining information from the galaxy density field and the weak lensing field. This method is based on the work of Amara et al., who use the galaxy density field to construct a bias-weighted convergence field κg. The main difference between Amara et al.'s work and our new implementation is that here we present another way to measure galaxy bias, using tomography instead of bias parametrizations. The correlation between κg and the true lensing field κ allows us to measure galaxy bias using different zero-lag correlations, such as / or /. Our method measures the linear bias factor on linear scales, under the assumption of no stochasticity between galaxies and matter. We use the Marenostrum Institut de Ciències de l'Espai (MICE) simulation to measure the linear galaxy bias for a flux-limited sample (i < 22.5) in tomographic redshift bins using this method. This article is the first that studies the accuracy and systematic uncertainties associated with the implementation of the method and the regime in which it is consistent with the linear galaxy bias defined by projected two-point correlation functions (2PCF). We find that our method is consistent with a linear bias at the per cent level for scales larger than 30 arcmin, while non-linearities appear at smaller scales. This measurement is a good complement to other measurements of bias, since it does not depend strongly on σ8 as do the 2PCF measurements. We will apply this method to the Dark Energy Survey Science Verification data in a follow-up article.

  20. A LOFAR census of non-recycled pulsars: average profiles, dispersion measures, flux densities, and spectra

    CERN Document Server

    Bilous, A; Kramer, M; Keane, E; Hessels, J; Stappers, B; Malofeev, V; Sobey, C; Breton, R; Cooper, S; Falcke, H; Karastergiou, A; Michilli, D; Osłowski, S; Sanidas, S; ter Veen, S; van Leeuwen, J; Verbiest, J; Weltevrede, P; Zarka, P; Grießmeier, J -M; Serylak, M; Bell, M; Broderick, J; Eislöffel, J; Markoff, S; Rowlinson, A

    2015-01-01

    We present first results from a LOFAR census of non-recycled pulsars. The census includes almost all such pulsars known (194 sources) at declinations Dec$> 8^\\circ$ and Galactic latitudes |Gb|$> 3^\\circ$, regardless of their expected flux densities and scattering times. Each pulsar was observed contiguously in the frequency range from 110$-$188 MHz and for $\\geq 20$ minutes, recording full-Stokes data. We present the dispersion measures, flux densities, and calibrated total intensity profiles for the 158 pulsars detected in the sample. The median uncertainty in census dispersion measures ($1.5 \\times 10^{-4}$ pc cm$^{-3}$) is ten times smaller, on average, than in the ATNF pulsar catalogue. We combined census flux densities with those in the literature and fitted the resulting broadband spectra with single or broken power-law functions. For 48 census pulsars such fits are being published for the first time. Typically, the choice between single and broken power-laws, as well as the location of the spectral bre...

  1. Subthreshold slope as a measure of interfacial trap density in pentacene films

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yongwoo; Park, Byoungnam, E-mail: metalpbn@hongik.ac.kr

    2016-01-29

    Electrical properties in organic field effect transistors (FETs) are dominated by charge transport in the accumulation layer, few molecular layers close to the gate dielectric. Through comparison of the subthreshold slope between monolayer (ML) and thick pentacene FETs, formation of the second layer islands on top of the complete first layer is found to be crucial in determining the charge transport in ML pentacene FETs. It is demonstrated that a pentacene ML field effect transistor (FET) is an excellent probe that can detect electronic states of organic semiconductors interfacing with the gate dielectric at nanometer scale. Far higher sub-threshold slope in ML FETs, as a measure of interfacial charge trap density, than that in thick pentacene FETs is translated that the path of the induced carriers in ML FETs is limited into the molecular layer interfacing with the gate dielectric with a high density of charge traps, while carriers in thicker films have alternative pathways through more electrically conductive layer above the first layer with much less trap density. - Highlights: • Sub-threshold slope is demonstrated to be a measure of interface traps. • For application to sensors, effective charge transport layer should be chosen. • Monolayer transistors can be used as a platform for probing localized states.

  2. Microwave Transmission Measurement of the Electron Cloud Density in the Positron Ring of PEP-II

    CERN Document Server

    Pivi, M T F; Byrd, J; De Santis, S; Sonnad, K G; Caspers, Friedhelm; Kroyer, T; Roncarolo, F

    2008-01-01

    Clouds of electrons in the vacuum chambers of accelerators of positively charged particle beams present a serious limitation for operation of these machines at high currents. Because of the size of these accelerators, it is difficult to probe the low energy electron clouds over substantial lengths of the beam pipe. We applied a novel technique to directly measure the electron cloud density via the phase shift induced in a TE wave which is independently excited and transmitted over a straight section of the accelerator. The modulation in the wave transmission which appear to increase in depth when the clearing solenoids are switched off, seem to be directly correlated to the electron cloud density in the section. Furthermore, we expect a larger phase shift of a wave transmitted through magnetic dipole field regions if the transmitted wave couples with the gyration motion of the electrons. We have used this technique to measure the average electron cloud density (ECD) specifically for the first time in magnetic...

  3. Speckle measurements of density and temperature profiles in a model gas circuit breaker

    Science.gov (United States)

    Stoller, P. C.; Panousis, E.; Carstensen, J.; Doiron, C. B.; Färber, R.

    2015-01-01

    Speckle imaging was used to measure the density and temperature distribution in the arc zone of a model high voltage circuit breaker during the high current phase and under conditions simulating those present during current-zero crossings (current-zero-like arc); the arc was stabilized by a transonic, axial flow of synthetic air. A single probe beam was used; thus, accurate reconstruction was only possible for axially symmetric gas flows and arc channels. The displacement of speckles with respect to a reference image was converted to a line-of-sight integrated deflection angle, which was in turn converted into an axially symmetric refractive index distribution using a multistep process that made use of the inverse Radon transform. The Gladstone-Dale relation, which gives the index of refraction as a function of density, was extended to high temperatures by taking into account dissociation and ionization processes. The temperature and density were determined uniquely by assuming that the pressure distribution in the case of cold gas flow (in the absence of an arc) is not modified significantly by the arc. The electric conductivity distribution was calculated from the temperature profile and compared to measurements of the arc voltage and to previous results published in the literature for similar experimental conditions.

  4. Imaging of 5f densities of states in resonant photoemission measurements

    Energy Technology Data Exchange (ETDEWEB)

    Arko, A.J.; Koelling, D.D.; Capasso, C.; del Giudice, M.; Olson, C.G.

    1988-07-15

    Medium-resolution spectra (..delta..E = 0.25 eV) at the 5f Fano resonance in uranium intermetallics are compared to spectra above and below the resonance region to show that the 5f (and 6d) spectral weight obtained from resonant photoemission (RP) compares well to the 5f spectral weight obtained at other photon energies. In well-hybridized systems, the 5f signal from RP gives an excellent representation of the 5f density of states (DOS). In narrow-band and localized systems, a satellite may appear in addition to 5f DOS-like structure, indicative of correlation effects.

  5. Hysteresis in Carbon Nanotube Transistors: Measurement and Analysis of Trap Density, Energy Level, and Spatial Distribution.

    Science.gov (United States)

    Park, Rebecca Sejung; Shulaker, Max Marcel; Hills, Gage; Suriyasena Liyanage, Luckshitha; Lee, Seunghyun; Tang, Alvin; Mitra, Subhasish; Wong, H-S Philip

    2016-04-26

    We present a measurement technique, which we call the Pulsed Time-Domain Measurement, for characterizing hysteresis in carbon nanotube field-effect transistors, and demonstrate its applicability for a broad range of 1D and 2D nanomaterials beyond carbon nanotubes. The Pulsed Time-Domain Measurement enables the quantification (density, energy level, and spatial distribution) of charged traps responsible for hysteresis. A physics-based model of the charge trapping process for a carbon nanotube field-effect transistor is presented and experimentally validated using the Pulsed Time-Domain Measurement. Leveraging this model, we discover a source of traps (surface traps) unique to devices with low-dimensional channels such as carbon nanotubes and nanowires (beyond interface traps which exist in today's silicon field-effect transistors). The different charge trapping mechanisms for interface traps and surface traps are studied based on their temperature dependencies. Through these advances, we are able to quantify the interface trap density for carbon nanotube field-effect transistors (∼3 × 10(13) cm(-2) eV(-1) near midgap), and compare this against a range of previously studied dielectric/semiconductor interfaces.

  6. Double Ionization Gauge for Atmosphere Density/Pressure Measurements On Board the Rocket

    Science.gov (United States)

    Yushkov, V.; Shturkov, O.; Balugin, N.; Zhurin, S.; Kusov, A.

    2015-09-01

    A description of the ionization gauge for atmospheric density/pressure measurements on board a Russian meteorological rocket is presented. Its operation is based on the principle employed in an ionization gauge. The measuring density/pressure range is 1 06 102 kg/m3 / 10 ~ - 10 mm Hg. There are two output channels for ion and electron current measurements, respectively. The calibration curves are in a fairly good agreement with the classical electron impact ionization theory. The calibration error is less than 7%, that has been definitely confirmed through laboratory bench calibration. This rocket-borne device does not require pre-flight sealing. It greatly simplifies the design of the flight device. The ionization source is an electron flux emitted from the surface of a semi-impermeable metal plate under the influence of vacuum ultraviolet (VUV) radiation. The vUv radiation source is a portable glow-discharge krypton lamp. The flight instrument has been tested for shock loads up to 200 g for rocket measurement applications.

  7. Absolute choline concentration measured by quantitative proton MR spectroscopy correlates with cell density in meningioma

    Energy Technology Data Exchange (ETDEWEB)

    Yue, Qiang [University of Tsukuba, Department of Neurosurgery, Institute of Clinical Medicine, Tsukuba Science City, Ibaraki (Japan)]|[West China Hospital of Sichuan University, Huaxi MR Research Center, Department of Radiology, Chengdu (China); Shibata, Yasushi; Kawamura, Hiraku; Matsumura, Akira [University of Tsukuba, Department of Neurosurgery, Institute of Clinical Medicine, Tsukuba Science City, Ibaraki (Japan); Isobe, Tomonori [Kitasato University, Department of Medical Technology, School of Allied Health Sciences, Minato, Tokyo (Japan); Anno, Izumi [University of Tsukuba, Department of Radiology, Institute of Clinical Medicine, Tsukuba, Ibaraki (Japan); Gong, Qi-Yong [West China Hospital of Sichuan University, Huaxi MR Research Center, Department of Radiology, Chengdu (China)]|[University of Liverpool, Division of Medical Imaging, Faculty of Medicine, Liverpool (United Kingdom)

    2009-01-15

    This study was aimed to investigate the relationship between quantitative proton magnetic resonance spectroscopy (1H-MRS) and pathological changes in meningioma. Twenty-two meningioma cases underwent single voxel 1H-MRS (point-resolved spectroscopy sequence, repetition time/echo time = 2,000 ms/68, 136, 272 ms). Absolute choline (Cho) concentration was calculated using tissue water as the internal reference and corrected according to intra-voxel cystic/necrotic parts. Pathological specimens were stained with MIB-1 antibody to measure cell density and proliferation index. Correlation analysis was performed between absolute Cho concentration and cell density and MIB-1 labeled proliferation index. Average Cho concentration of all meningiomas before correction was 2.95 {+-} 0.86 mmol/kg wet weight. It was increased to 3.23 {+-} 1.15 mmol/kg wet weight after correction. Average cell density of all meningiomas was 333 {+-} 119 cells/HPF, and average proliferation index was 2.93 {+-} 5.72%. A linear, positive correlation between cell density and Cho concentration was observed (r = 0.650, P = 0.001). After correction of Cho concentration, the correlation became more significant (r = 0.737, P < 0.001). However, no significant correlation between Cho concentration and proliferation index was found. There seemed to be a positive correlation trend after correction of Cho concentration but did not reach significant level. Absolute Cho concentration, especially Cho concentration corrected according to intra-voxel cystic/necrotic parts, reflects cell density of meningioma. (orig.)

  8. A measurement-driven adaptive probability hypothesis density filter for multitarget tracking

    Institute of Scientific and Technical Information of China (English)

    Si Weijian; Wang Liwei; Qu Zhiyu

    2015-01-01

    This paper studies the dynamic estimation problem for multitarget tracking. A novel gat-ing strategy that is based on the measurement likelihood of the target state space is proposed to improve the overall effectiveness of the probability hypothesis density (PHD) filter. Firstly, a measurement-driven mechanism based on this gating technique is designed to classify the measure-ments. In this mechanism, only the measurements for the existing targets are considered in the update step of the existing targets while the measurements of newborn targets are used for exploring newborn targets. Secondly, the gating strategy enables the development of a heuristic state estima-tion algorithm when sequential Monte Carlo (SMC) implementation of the PHD filter is investi-gated, where the measurements are used to drive the particle clustering within the space gate. The resulting PHD filter can achieve a more robust and accurate estimation of the existing targets by reducing the interference from clutter. Moreover, the target birth intensity can be adaptive to detect newborn targets, which is in accordance with the birth measurements. Simulation results demonstrate the computational efficiency and tracking performance of the proposed algorithm. ? 2015 The Authors. Production and hosting by Elsevier Ltd. on behalf of CSAA&BUAA. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

  9. Density of Liquid Ni-Mo Alloys Measured by a Modified Sessile Drop Method

    Institute of Scientific and Technical Information of China (English)

    Liang FANG; Zushu LI; ZaiNan TAO; Feng XIAO

    2004-01-01

    The density of liquid binary Ni-Mo alloys with molybdenum concentration from 0 to 20% (mass fraction) was measured by a modified sessile drop method. It has been found that the density of the liquid Ni-Mo alloys decreases with increasing temperature, but increases with the increase of molybdenum concentration in the alloys. The molar volume of liquid Ni-Mo binary alloys increases with the increase of temperature and molybdenum concentration. The partial molar volume of molybdenum in Ni-Mo binary alloy has been approximately calculated as [13.18 - 2.65 × 10-3T + (-47.94 + 3.10 × 10-2T) × 10-2XMo] × 10-6m3·mol-1. The molar volume of Ni-Mo alloy determined in the present work shows a negative deviation from the ideal linear mixing molar volume.

  10. The outcome of bone mineral density measurements on patients referred from general practice

    DEFF Research Database (Denmark)

    Iqbal, Sofia Inez; Mørch, Lina Steinrud; Rosenzweig, Mary

    2005-01-01

    calculated with respect to patient characteristics. Only 21% of the referred patients had osteoporosis and 34% had osteopenia. Of these, 24% had osteopenia and a Z-score below -1. Half of the referred patients were women less than 60 yr with a markedly low risk of osteoporosis. A BMI less than 20 kg/m(2......The incidence of osteoporosis is increasing and the general practitioner is integral to identifying these patients. It is, therefore, of interest to characterize the referral pattern of patients scheduled for determination of bone density by means of dual-energy X-ray absorptiometry scanning......) increased the predictive value considerably. A low BMI is a good indicator for referral of women less than 60 yr for measurements of bone density. Forty-five percent of the referred women from general practitioners had a normal BMD....

  11. The Correlation between Dispersion Measure and X-ray Column Density from Radio Pulsars

    CERN Document Server

    He, C; Kaspi, V M

    2013-01-01

    Pulsars are remarkable objects that emit across the entire electromagnetic spectrum, providing a powerful probe of the interstellar medium. In this study, we investigate the relation between dispersion measure (DM) and X-ray absorption column density NH using 68 radio pulsars detected at X-ray energies with the Chandra X-ray Observatory or XMM-Newton. We find a best-fit empirical linear relation of NH (10^20 cm^-2)= 0.30+0.13-0.09 DM (pc cm^-3), which corresponds to an average ionization of 10+4-3%, confirming the ratio of one free electron per ten neutral hydrogen atoms commonly assumed in the literature. We also compare different NH estimates and note that some NH values obtained from X-ray observations are higher than the total Galactic HI column density along the same line of sight, while the optical extinction generally gives the best NH predictions.

  12. New Microwave Diagnostic Theory for Measurement of Electron Density in Atmospheric Plasmas

    Institute of Scientific and Technical Information of China (English)

    ZHANG Shu; HU Xi-Wei

    2005-01-01

    @@ We present the phase shift of an electromagnetic wave passing through an atmospheric plasma layer. In this kind of plasma, the phase shift depends not only on the line average electron density and layer width, but also on the electron-neutral collision frequency. Since the collision frequency is close to or even larger than the incident microwave frequency, a one-dimensional code for the numerical solution of the wave equation with full time and space variables is established to give the phase shift. When the width and the pressure (hence the electron-neutral collision frequency) are known, the measurement of phase shift will uniquely determine the line average electrons density in an atmospheric plasma.

  13. High Temperature Superconducting Maglev Measurement System

    OpenAIRE

    Wang, Jia-Su; Wang, Su-Yu

    2010-01-01

    Three high temperature superconducting (HTS) Maglev measurement systems were successfully developed in the Applied Superconductivity Laboratory (ASCLab) of Southwest Jiaotong University, P. R. China. These systems include liquid nitrogen vessel, Permanent Magnet Guideway (PMG), data collection and processing, mechanical drive and Autocontrol features. This chapter described the three different measuring systems along with their theory of operations and workflow. The SCML-01 HTS Maglev measure...

  14. Absorption Measurement of Zn Atom Density during ICP-assisted Magnetron Sputter-deposition of Al-doped ZnO Thin Films

    OpenAIRE

    2009-01-01

    This paper reports the outlines of hollow cathode (HCD) lamp absorption system for the density measurement of sputtered metal atoms in the inductively coupled plasma (ICP) assisted sputter-deposition process of Al doped ZnO thin films. As a result, absorbance of about 6.5% was obtained, which corresponds to the Zn atom density of 1.5×1012 cm-3.

  15. Improving Measurement of Forest Structural Parameters by Co-Registering of High Resolution Aerial Imagery and Low Density LiDAR Data

    OpenAIRE

    Huang, Huabing; Gong, Peng; CHENG, XIAO; Clinton, Nick; Li, Zengyuan

    2009-01-01

    Forest structural parameters, such as tree height and crown width, are indispensable for evaluating forest biomass or forest volume. LiDAR is a revolutionary technology for measurement of forest structural parameters, however, the accuracy of crown width extraction is not satisfactory when using a low density LiDAR, especially in high canopy cover forest. We used high resolution aerial imagery with a low density LiDAR system to overcome this shortcoming. A morphological filtering was used to ...

  16. Electron density and electron temperature measurements in nanosecond pulse discharges over liquid water surface

    Science.gov (United States)

    Simeni Simeni, M.; Roettgen, A.; Petrishchev, V.; Frederickson, K.; Adamovich, I. V.

    2016-12-01

    Time-resolved electron density, electron temperature, and gas temperature in nanosecond pulse discharges in helium and O2-He mixtures near liquid water surface are measured using Thomson/pure rotational Raman scattering, in two different geometries, (a) ‘diffuse filament’ discharge between a spherical high-voltage electrode and a grounded pin electrode placed in a reservoir filled with distilled water, with the tip exposed, and (b) dielectric barrier discharge between the high-voltage electrode and the liquid water surface. A diffuse plasma filament generated between the electrodes in helium during the primary discharge pulse exhibits noticeable constriction during the secondary discharge pulse several hundred ns later. Adding oxygen to the mixture reduces the plasma filament diameter and enhances constriction during the secondary pulse. In the dielectric barrier discharge, diffuse volumetric plasma occupies nearly the entire space between the high voltage electrode and the liquid surface, and extends radially along the surface. In the filament discharge in helium, adding water to the container results in considerable reduction of plasma lifetime compared to the discharge in dry helium, by about an order of magnitude, indicating rapid electron recombination with water cluster ions. Peak electron density during the pulse is also reduced, by about a factor of two, likely due to dissociative attachment to water vapor during the discharge pulse. These trends become more pronounced as oxygen is added to the mixture, which increases net rate of dissociative attachment. Gas temperature during the primary discharge pulse remains near room temperature, after which it increases up to T ~ 500 K over 5 µs and decays back to near room temperature before the next discharge pulse several tens of ms later. As expected, electron density and electron temperature in diffuse DBD plasmas are considerably lower compared to peak values in the filament discharge. Use of Thomson

  17. 600-GHz Electronically Tunable Vector Measurement System

    Science.gov (United States)

    Dengler, Robert; Maiwald, Frank; Siegel, Peter

    2007-01-01

    A compact, high-dynamic-range, electronically tunable vector measurement system that operates in the frequency range from approximately 560 to approximately 635 GHz has been developed as a prototype of vector measurement systems that would be suitable for use in nearly-real-time active submillimeter-wave imaging. As used here, 'vector measurement system" signifies an instrumentation system that applies a radio-frequency (RF) excitation to an object of interest and measures the resulting amplitude and phase response, relative to either the applied excitatory signal or another reference signal related in a known way to applied excitatory signal.

  18. Using a Differential Emission Measure and Density Measurements in an Active Region Core to Test a Steady Heating Model

    Science.gov (United States)

    Winebarger, Amy R.; Schmelz, Joan T.; Warren, Harry P.; Saar, Steve H.; Kashyap, Vinay L.

    2011-10-01

    The frequency of heating events in the corona is an important constraint on the coronal heating mechanisms. Observations indicate that the intensities and velocities measured in active region cores are effectively steady, suggesting that heating events occur rapidly enough to keep high-temperature active region loops close to equilibrium. In this paper, we couple observations of active region (AR) 10955 made with the X-Ray Telescope and the EUV Imaging Spectrometer on board Hinode to test a simple steady heating model. First we calculate the differential emission measure (DEM) of the apex region of the loops in the active region core. We find the DEM to be broad and peaked around 3 MK. We then determine the densities in the corresponding footpoint regions. Using potential field extrapolations to approximate the loop lengths and the density-sensitive line ratios to infer the magnitude of the heating, we build a steady heating model for the active region core and find that we can match the general properties of the observed DEM for the temperature range of 6.3 accounts for the base pressure, loop length, and distribution of apex temperatures of the core loops. We find that the density-sensitive spectral line intensities and the bulk of the hot emission in the active region core are consistent with steady heating. We also find, however, that the steady heating model cannot address the emission observed at lower temperatures. This emission may be due to foreground or background structures, or may indicate that the heating in the core is more complicated. Different heating scenarios must be tested to determine if they have the same level of agreement.

  19. Development and Miniaturization of RF based probes for Electron Density Measurements

    Science.gov (United States)

    Nakamura, Keiji

    2016-09-01

    To make a diagnostics on plasmas for materials processing plasmas accompanying with deposition of non-conducting films in etching and/or CVD processes, curling probe (CP) with a spiral slot antenna has been recently developed as a compact diagnostic tool which enables the local electron density measurement. The electron density is obtained from a shift of the probe resonance frequency in discharge ON and OFF monitored by a network analyzer (NWA). A conventional CP has a diameter larger than 15 mm typically, because a slot length of the CP is as long as several tens millimeters for its resonance frequency less than several GHz. Further miniaturization of the CP was required to expand applicable range to various plasma sources like a narrow-gap parallel plate discharge. We tried miniaturization of the CP down to less than 3 mm in the probe diameter by fabricating narrow spiral slot antenna, and experimentally and numerically the miniaturized probe was investigated how much influence the slot width has on probe resonance characteristics and electron density measurements. In the case of the conventional CP made of stainless steel, 0.3-mm-wide normal slot antenna, the resonance spectra was clearly observed regardless of antenna materials of copper or stainless steel (SS). However, when the slot width was reduced down to 0.03 mm, the slot resonance was strongly dependent on the antenna materials. Namely the resonance peak was almost vanished for the SS antenna, whereas clearly appeared for the copper antenna. In general, the narrower the slot is, the higher attenuation factor the slot has for electromagnetic wave propagating along the slot. In such an attenuated transmission line of the narrow slot, high electric conductivity of the antenna seems preferable for the slot resonance. Furthermore, the miniaturized CP with the copper antenna was also introduced into low pressure (< 1Pa) Ar plasma. The resonance frequency was confirmed to changes sensitively with electron

  20. Particle filters for probability hypothesis density filter with the presence of unknown measurement noise covariance

    Institute of Scientific and Technical Information of China (English)

    Wu Xinhui; Huang Gaoming; Gao Jun

    2013-01-01

    In Bayesian multi-target filtering, knowledge of measurement noise variance is very important. Significant mismatches in noise parameters will result in biased estimates. In this paper, a new particle filter for a probability hypothesis density (PHD) filter handling unknown measure-ment noise variances is proposed. The approach is based on marginalizing the unknown parameters out of the posterior distribution by using variational Bayesian (VB) methods. Moreover, the sequential Monte Carlo method is used to approximate the posterior intensity considering non-lin-ear and non-Gaussian conditions. Unlike other particle filters for this challenging class of PHD fil-ters, the proposed method can adaptively learn the unknown and time-varying noise variances while filtering. Simulation results show that the proposed method improves estimation accuracy in terms of both the number of targets and their states.