WorldWideScience

Sample records for delivery systems usability

  1. Applying usability heuristics to radiotherapy systems

    International Nuclear Information System (INIS)

    Chan, Alvita J.; Islam, Mohammad K.; Rosewall, Tara; Jaffray, David A.; Easty, Anthony C.; Cafazzo, Joseph A.

    2012-01-01

    Background and purpose: Heuristic evaluations have been used to evaluate safety of medical devices by identifying and assessing usability issues. Since radiotherapy treatment delivery systems often consist of multiple complex user-interfaces, a heuristic evaluation was conducted to assess the potential safety issues of such a system. Material and methods: A heuristic evaluation was conducted to evaluate the treatment delivery system at Princess Margaret Hospital (Toronto, Canada). Two independent evaluators identified usability issues with the user-interfaces and rated the severity of each issue. Results: The evaluators identified 75 usability issues in total. Eighteen of them were rated as high severity, indicating the potential to have a major impact on patient safety. A majority of issues were found on the record and verify system, and many were associated with the patient setup process. While the hospital has processes in place to ensure patient safety, recommendations were developed to further mitigate the risks of potential consequences. Conclusions: Heuristic evaluation is an efficient and inexpensive method that can be successfully applied to radiotherapy delivery systems to identify usability issues and improve patient safety. Although this study was conducted only at one site, the findings may have broad implications for the design of these systems.

  2. Toward more usable electronic voting: testing the usability of a smartphone voting system.

    Science.gov (United States)

    Campbell, Bryan A; Tossell, Chad C; Byrne, Michael D; Kortum, Philip

    2014-08-01

    The goal of this research was to assess the usability of a voting system designed for smart-phones. Smartphones offer remote participation in elections through the use of pervasive technology. Voting on these devices could, among other benefits, increase voter participation while allowing voters to use familiar technology. However, the usability of these systems has not been assessed. A mobile voting system optimized for use on a smartphone was designed and tested against traditional voting platforms for usability. There were no reliable differences between the smartphone-based system and other voting methods in efficiency and perceived usability. More important, though, smartphone owners committed fewer errors on the mobile voting system than on the traditional voting systems. Even with the known limitations of small mobile platforms in both displays and controls, a carefully designed system can provide a usable voting method. Much of the concern about mobile voting is in the area of security; therefore, although these results are promising, security concerns and usability issues arising from mitigating them must be strongly considered. The results of this experiment may help to inform current and future election and public policy officials about the benefits of allowing voters to vote with familiar hardware.

  3. Usability Problems in a Home Telemedicine System

    DEFF Research Database (Denmark)

    Bruun, Anders; Stage, Jan

    2010-01-01

    a high level of usability in order to enable their users to employ the required functionality, especially if the target user group is elderly people. This paper reports from a usability evaluation of a home telemedicine system. Five elderly persons carried out specified tasks with the system, and based...... on that we identified usability problems with the system. The problems are presented, analysed in relation to 12 different usability themes and related to results from other evaluations of similar systems....

  4. Commercial versus in-situ usability testing of healthcare information systems: towards "public" usability testing in healthcare organizations.

    Science.gov (United States)

    Kushniruk, Andre W; Borycki, Elizabeth M; Kannry, Joseph

    2013-01-01

    The need for improved usability in healthcare IT has been widely recognized. In addition, methods from usability engineering, including usability testing and usability inspection have received greater attention. Many vendors of healthcare software are now employing usability testing methods in the design and development of their products. However, despite this, the usability of healthcare IT is still considered to be problematic and many healthcare organizations that have purchased systems that have been tested at vendor testing sites are still reporting a range of usability and safety issues. In this paper we explore the distinction between commercial usability testing (conducted at centralized vendor usability laboratories and limited beta test sites) and usability testing that is carried out locally within healthcare organizations that have purchased vendor systems and products (i.e. public "in-situ" usability testing). In this paper it will be argued that both types of testing (i.e. commercial vendor-based testing) and in-situ testing are needed to ensure system usability and safety.

  5. A Cross-Cultural Study of How Usability Professionals Experience the Usability of Everyday Systems

    DEFF Research Database (Denmark)

    Jiang, Y.; Sun, X.; Li, H.

    2009-01-01

    in the study, their understanding of fun systems differs across cultural backgrounds. Also, easy-to-use and useful systems are perceived as being similar or different depending on the usability professional’s cultural background. Most other cross-cultural differences relate to categories of construct......Culture influences many aspects of the design and use of computer systems; understanding better this influence on their own thinking may benefit usability professionals who do cross-cultural usability work. Using Kelly’s notion of personal constructs, we focus on one mediator of culture: how...

  6. Towards a Usability and Error "Safety Net": A Multi-Phased Multi-Method Approach to Ensuring System Usability and Safety.

    Science.gov (United States)

    Kushniruk, Andre; Senathirajah, Yalini; Borycki, Elizabeth

    2017-01-01

    The usability and safety of health information systems have become major issues in the design and implementation of useful healthcare IT. In this paper we describe a multi-phased multi-method approach to integrating usability engineering methods into system testing to ensure both usability and safety of healthcare IT upon widespread deployment. The approach involves usability testing followed by clinical simulation (conducted in-situ) and "near-live" recording of user interactions with systems. At key stages in this process, usability problems are identified and rectified forming a usability and technology-induced error "safety net" that catches different types of usability and safety problems prior to releasing systems widely in healthcare settings.

  7. Usability Evaluation of a Web-Based Learning System

    Science.gov (United States)

    Nguyen, Thao

    2012-01-01

    The paper proposes a contingent, learner-centred usability evaluation method and a prototype tool of such systems. This is a new usability evaluation method for web-based learning systems using a set of empirically-supported usability factors and can be done effectively with limited resources. During the evaluation process, the method allows for…

  8. Course management systems from a usability perspective

    CSIR Research Space (South Africa)

    Padayachee, I

    2011-01-01

    Full Text Available (with knowledge of usability engineering and system domain knowledge) who inspect the Indira Padayachee, Paula Kotz? and Alta van der Merwe 302 interface and determine its compliance with recognized usability principles (the ?heuristics... presents a summary of the results of the severity rating. Table 2: Severity Rating Scale for Usability Problems (Nielsen 2007b) 0 I don?t agree that this is a usability problem at all 1 Cosmetic problem only: need not be fixed unless there is extra...

  9. Business-Intelligence-Systeme im Spannungsfeld zwischen Usability und Sicherheit

    OpenAIRE

    Hinck, Thorsten

    2010-01-01

    Business-Intelligence-Systeme stehen im Spannungsfeld zwischen Usability und Sicherheit. Die Gefahren und Sicherheitsmaßnahmen für Informationssysteme werden ermittelt und ökonomisch in Bezug zur Gebrauchstauglichkeit gesetzt. Es entsteht ein Sicherheitsprofil für Business-Intelligence-Systeme. Business-Intelligence-Systems are in tension between Usability and IT-Security. Risks and safety measures of informationsystems are defined and set in (economic) regard to Usability. A security prof...

  10. Usability engineering: domain analysis activities for augmented-reality systems

    Science.gov (United States)

    Gabbard, Joseph; Swan, J. E., II; Hix, Deborah; Lanzagorta, Marco O.; Livingston, Mark; Brown, Dennis B.; Julier, Simon J.

    2002-05-01

    This paper discusses our usability engineering process for the Battlefield Augmented Reality System (BARS). Usability engineering is a structured, iterative, stepwise development process. Like the related disciplines of software and systems engineering, usability engineering is a combination of management principals and techniques, formal and semi- formal evaluation techniques, and computerized tools. BARS is an outdoor augmented reality system that displays heads- up battlefield intelligence information to a dismounted warrior. The paper discusses our general usability engineering process. We originally developed the process in the context of virtual reality applications, but in this work we are adapting the procedures to an augmented reality system. The focus of this paper is our work on domain analysis, the first activity of the usability engineering process. We describe our plans for and our progress to date on our domain analysis for BARS. We give results in terms of a specific urban battlefield use case we have designed.

  11. Usability evaluation of Laboratory and Radiology Information Systems integrated into a hospital information system.

    Science.gov (United States)

    Nabovati, Ehsan; Vakili-Arki, Hasan; Eslami, Saeid; Khajouei, Reza

    2014-04-01

    This study was conducted to evaluate the usability of widely used laboratory and radiology information systems. Three usability experts independently evaluated the user interfaces of Laboratory and Radiology Information Systems using heuristic evaluation method. They applied Nielsen's heuristics to identify and classify usability problems and Nielsen's severity rating to judge their severity. Overall, 116 unique heuristic violations were identified as usability problems. In terms of severity, 67 % of problems were rated as major and catastrophic. Among 10 heuristics, "consistency and standards" was violated most frequently. Moreover, mean severity of problems concerning "error prevention" and "help and documentation" heuristics was higher than of the others. Despite widespread use of specific healthcare information systems, they suffer from usability problems. Improving the usability of systems by following existing design standards and principles from the early phased of system development life cycle is recommended. Especially, it is recommended that the designers design systems that inhibit the initiation of erroneous actions and provide sufficient guidance to users.

  12. Evaluating Usability of E-Learning Systems in Universities

    OpenAIRE

    Nicholas Kipkurui Kiget; Professor G. Wanyembi; Anselemo Ikoha Peters

    2014-01-01

    The use of e-learning systems has increased significantly in the recent times. E-learning systems are supplementing teaching and learning in universities globally. Kenyan universities have adopted e-learning technologies as means for delivering course content. However despite adoption of these systems, there are considerable challenges facing the usability of the systems. Lecturers and students have different perceptions in regard to the usability of e-learning systems. The aim of this study ...

  13. Qualitative review of usability problems in health information systems for radiology.

    Science.gov (United States)

    Dias, Camila Rodrigues; Pereira, Marluce Rodrigues; Freire, André Pimenta

    2017-12-01

    Radiology processes are commonly supported by Radiology Information System (RIS), Picture Archiving and Communication System (PACS) and other software for radiology. However, these information technologies can present usability problems that affect the performance of radiologists and physicians, especially considering the complexity of the tasks involved. The purpose of this study was to extract, classify and analyze qualitatively the usability problems in PACS, RIS and other software for radiology. A systematic review was performed to extract usability problems reported in empirical usability studies in the literature. The usability problems were categorized as violations of Nielsen and Molich's usability heuristics. The qualitative analysis indicated the causes and the effects of the identified usability problems. From the 431 papers initially identified, 10 met the study criteria. The analysis of the papers identified 90 instances of usability problems, classified into categories corresponding to established usability heuristics. The five heuristics with the highest number of instances of usability problems were "Flexibility and efficiency of use", "Consistency and standards", "Match between system and the real world", "Recognition rather than recall" and "Help and documentation", respectively. These problems can make the interaction time consuming, causing delays in tasks, dissatisfaction, frustration, preventing users from enjoying all the benefits and functionalities of the system, as well as leading to more errors and difficulties in carrying out clinical analyses. Furthermore, the present paper showed a lack of studies performed on systems for radiology, especially usability evaluations using formal methods of evaluation involving the final users. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Investigation of the Usability of Computerized Critical Care Information Systems in Germany.

    Science.gov (United States)

    von Dincklage, Falk; Suchodolski, Klaudiusz; Lichtner, Gregor; Friesdorf, Wolfgang; Podtschaske, Beatrice; Ragaller, Maximilian

    2017-01-01

    The term "usability" describes how effectively, efficiently, and with what level of user satisfaction an information system can be used to accomplish specific goals. Computerized critical care information systems (CCISs) with high usability increase quality of care and staff satisfaction, while reducing medication errors. Conversely, systems lacking usability can interrupt clinical workflow, facilitate errors, and increase charting time. The aim of this study was to investigate and compare usability across CCIS currently used in Germany. In this study, German intensive care unit (ICU) nurses and physicians completed a specialized, previously validated, web-based questionnaire. The questionnaire assessed CCIS usability based on three rating models: an overall rating of the systems, a model rating technical usability, and a model rating task-specific usability. We analyzed results from 535 survey participants and compared eight different CCIS commonly used in Germany. Our results showed that usability strongly differs across the compared systems. The system ICUData had the best overall rating and technical usability, followed by the platforms ICM and MetaVision. The same three systems performed best in the rating of task-specific usability without significant differences between each other. Across all systems, overall ratings were more dependent on ease-of-use aspects than on aspects of utility/functionality, and the general scope of the functions offered was rated better than how well the functions are realized. Our results suggest that manufacturers should shift some of their effort away from the development of new features and focus more on improving the ease-of-use and quality of existing features.

  15. Usability challenges in an Ethiopian software development organization

    DEFF Research Database (Denmark)

    Teka, Degif; Dittrich, Yvonne; Kifle, Mesfin

    2016-01-01

    Usability and user centered design (UCD) are central to software development. In developing countries, the gap between IT development and the local use situation is larger than in western countries. However, usability is neither well addressed in software practice nor at the policy making level...... in Ethiopia. Software practitioners focus on functional requirements, meeting deadlines and budget. The software development industry in Ethiopia is in its early stage. The article aims at understanding usability practices in an Ethiopian software development company. Developers, system analysts, product...... configuration, their experience, cultural knowledge and common sense regarding the users' situation guided the design. Prototypes and fast delivery of working versions helped in getting user feedback even if early user focus proved to be a challenge as communication between developers and users suffered from...

  16. Images of Usability

    DEFF Research Database (Denmark)

    Hertzum, Morten

    2010-01-01

    unless confronted with alternative images. This study delineates six images of usability: universal usability, situational usability, perceived usability, hedonic usability, organizational usability, and cultural usability. The different foci of the images provide opportunities for becoming sensitized...... assume different images of usability and a need for supplementary methods addressing the collaborative and long-term aspects of usability. Moreover, the images call for extending the scope of practical usability work to include the effects achieved by users during their use of systems for real work....

  17. On the Usability of Spoken Dialogue Systems

    DEFF Research Database (Denmark)

    Larsen, Lars Bo

     This work is centred on the methods and problems associated with defining and measuring the usability of Spoken Dialogue Systems (SDS). The starting point is the fact that speech based interfaces has several times during the last 20 years fallen short of the high expectations and predictions held...... by industry, researchers and analysts. Several studies in the literature of SDS indicate that this can be ascribed to a lack of attention from the speech technology community towards the usability of such systems. The experimental results presented in this work are based on a field trial with the OVID home...

  18. Health Information Technology Usability Evaluation Scale (Health-ITUES) for Usability Assessment of Mobile Health Technology: Validation Study.

    Science.gov (United States)

    Schnall, Rebecca; Cho, Hwayoung; Liu, Jianfang

    2018-01-05

    Mobile technology has become a ubiquitous technology and can be particularly useful in the delivery of health interventions. This technology can allow us to deliver interventions to scale, cover broad geographic areas, and deliver technologies in highly tailored ways based on the preferences or characteristics of users. The broad use of mobile technologies supports the need for usability assessments of these tools. Although there have been a number of usability assessment instruments developed, none have been validated for use with mobile technologies. The goal of this work was to validate the Health Information Technology Usability Evaluation Scale (Health-ITUES), a customizable usability assessment instrument in a sample of community-dwelling adults who were testing the use of a new mobile health (mHealth) technology. A sample of 92 community-dwelling adults living with HIV used a new mobile app for symptom self-management and completed the Health-ITUES to assess the usability of the app. They also completed the Post-Study System Usability Questionnaire (PSSUQ), a widely used and well-validated usability assessment tool. Correlations between these scales and each of the subscales were assessed. The subscales of the Health-ITUES showed high internal consistency reliability (Cronbach alpha=.85-.92). Each of the Health-ITUES subscales and the overall scale was moderately to strongly correlated with the PSSUQ scales (r=.46-.70), demonstrating the criterion validity of the Health-ITUES. The Health-ITUES has demonstrated reliability and validity for use in assessing the usability of mHealth technologies in community-dwelling adults living with a chronic illness. ©Rebecca Schnall, Hwayoung Cho, Jianfang Liu. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 05.01.2018.

  19. A Novel Multifactor Authentication System Ensuring Usability and Security

    OpenAIRE

    Mathew, Gloriya; Thomas, Shiney

    2013-01-01

    User authentication is one of the most important part of information security. Computer security most commonly depends on passwords to authenticate human users. Password authentication systems will be either been usable but not secure, or secure but not usable. While there are different types of authentication systems available alphanumeric password is the most commonly used authentication mechanism. But this method has significant drawbacks. An alternative solution to the text based authenti...

  20. Integration of MSFC Usability Lab with Usability Testing

    Science.gov (United States)

    Cheng, Yiwei; Richardson, Sally

    2010-01-01

    As part of the Stage Analysis Branch, human factors engineering plays an important role in relating humans to the systems of hardware and structure designs of the new launch vehicle. While many branches are involved in the technical aspects of creating a launch vehicle, human factors connects humans to the scientific systems with the goal of improving operational performance and safety while reducing operational error and damage to the hardware. Human factors engineers use physical and computerized models to visualize possible areas for improvements to ensure human accessibility to components requiring maintenance and that the necessary maintenance activities can be accomplished with minimal risks to human and hardware. Many methods of testing are used to fulfill this goal, such as physical mockups, computerized visualization, and usability testing. In this analysis, a usability test is conducted to test how usable a website is to users who are and are not familiar with it. The testing is performed using participants and Morae software to record and analyze the results. This analysis will be a preliminary test of the usability lab in preparation for use in new spacecraft programs, NASA Enterprise, or other NASA websites. The usability lab project is divided into two parts: integration of the usability lab and a preliminary test of the usability lab.

  1. Hello World! - Experiencing Usability Methods without Usability Expertise

    Science.gov (United States)

    Eriksson, Elina; Cajander, Åsa; Gulliksen, Jan

    How do you do usability work when no usability expertise is available? What happens in an organization when system developers, with no previous HCI knowledge, after a 3-day course, start applying usability methods, and particularly field studies? In order to answer these questions qualitative data were gathered through participatory observations, a feed back survey, field study documentation and interviews from 47 system developers from a public authority. Our results suggest that field studies enhance the developer’s understanding of the user perspective, and provide a more holistic overview of the use situation, but that some developers were unable to interpret their observations and see solutions to the users’ problems. The field study method was very much appreciated and has now become standard operating procedure within the organization. However, although field studies may be useful, it does not replace the need for usability pro fes sion als, as their knowledge is essential for more complex observations, analysis and for keeping the focus on usability.

  2. National questionnaire study on clinical ICT systems proofs: physicians suffer from poor usability.

    Science.gov (United States)

    Viitanen, Johanna; Hyppönen, Hannele; Lääveri, Tinja; Vänskä, Jukka; Reponen, Jarmo; Winblad, Ilkka

    2011-10-01

    In the health informatics field, usability studies typically focus on evaluating a single information system and involve a rather small group of end-users. However, little is known about the usability of clinical information and communication technology (ICT) environment in which healthcare professionals work daily. This paper aims at contributing to usability research and user-oriented development of healthcare technologies with three objectives: inform researchers and practitioners about the current state of usability of clinical ICT systems, increase the understanding of usability aspects specific for clinical context, and encourage a more holistic approach on studying usability issues in health informatics field. A national web questionnaire study was conducted in Finland in spring 2010 with 3929 physicians actively working in patient care. For the purposes of the study, we described three dimensions of clinical ICT system usability that reflect the physicians' viewpoint on system usage: (1) compatibility between clinical ICT systems and physicians' tasks, (2) ICT support for information exchange, communication and collaboration in clinical work, and (3) interoperability and reliability. The dimensions derive from the definitions of usability and clinical context of use analysis, and reflect the ability of ICT systems to have a positive impact on patient care by supporting physicians in achieving their goals with a pleasant user experience. The research data incorporated 32 statements with a five-point Likert-scale on physicians' experiences on usability of their currently used ICT systems and a summative question about school grade given to electronic health record (EHR) systems. Physicians' estimates of their EHR systems were very critical. With the rating scale from 4 or fail to 10 or excellent, the average of the grades varied from 6.1 to 8.4 dependent on the kind of facility the physician is working. Questionnaire results indicated several usability

  3. Evaluating Distributed Usability: the role of user interfaces in an activity system

    Directory of Open Access Journals (Sweden)

    Lejla Vrazalic

    2003-11-01

    Full Text Available Traditional definitions of usability localise this fundamental Human Computer Interaction (HCI concept in the user interface and reduce it to a variety of qualitative and quantitative attributes of the computer system. This simplistic view of usability has been used as the basis for developing design and evaluation methods in the discipline. This paper argues that, as a result, HCI methods are ineffective and suffer from various shortcomings. It is proposed that the notion of usability must be extended to include contextual factors, and viewed as being distributed across an activity system. Adopting this notion of distributed usability then requires a review of existing HCI methods. Usability testing, as a complete and self-contained HCI method, was chosen for this purpose, and the result, a distributed usability evaluation method (DUEM, is presented in this paper.

  4. Usability Study of a Computer-Based Self-Management System for Older Adults with Chronic Diseases

    Science.gov (United States)

    Tao, Da

    2012-01-01

    Background Usability can influence patients’ acceptance and adoption of a health information technology. However, little research has been conducted to study the usability of a self-management health care system, especially one geared toward elderly patients. Objective This usability study evaluated a new computer-based self-management system interface for older adults with chronic diseases, using a paper prototype approach. Methods Fifty older adults with different chronic diseases participated. Two usability evaluation methods were involved: (1) a heuristics evaluation and (2) end-user testing with a think-aloud testing method, audio recording, videotaping, and interviewing. A set of usability metrics was employed to determine the overall system usability, including task incompletion rate, task completion time, frequency of error, frequency of help, satisfaction, perceived usefulness, and perceived ease of use. Interviews were used to elicit participants’ comments on the system design. The quantitative data were analyzed using descriptive statistics and the qualitative data were analyzed for content. Results The participants were able to perform the predesigned self-management tasks with the current system design and they expressed mostly positive responses about the perceived usability measures regarding the system interface. However, the heuristics evaluation, performance measures, and interviews revealed a number of usability problems related to system navigation, information search and interpretation, information presentation, and readability. Design recommendations for further system interface modifications were discussed. Conclusions This study verified the usability of the self-management system developed for older adults with chronic diseases. Also, we demonstrated that our usability evaluation approach could be used to quickly and effectively identify usability problems in a health care information system at an early stage of the system development

  5. Usability Constructs

    DEFF Research Database (Denmark)

    Hertzum, Morten; Clemmesen, Torkil; Hornbæk, Kasper Anders Søren

    2007-01-01

    Whereas research on usability predominantly employs universal definitions of the aspects that comprise usability, people experience their use of information systems through personal constructs. Based on 48 repertory-grid interviews, this study investigates how such personal constructs are affected...... use of constructs traditionally associated with usability (e.g., easy-to-use, intuitive, and liked). Further analysis of the data is ongoing...

  6. Usability Evaluation of Electronic Health Record System around Clinical Notes Usage-An Ethnographic Study.

    Science.gov (United States)

    Rizvi, Rubina F; Marquard, Jenna L; Hultman, Gretchen M; Adam, Terrence J; Harder, Kathleen A; Melton, Genevieve B

    2017-10-01

    Background A substantial gap exists between current Electronic Health Record (EHR) usability and potential optimal usability. One of the fundamental reasons for this discrepancy is poor incorporation of a User-Centered Design (UCD) approach during the Graphical User Interface (GUI) development process. Objective To evaluate usability strengths and weaknesses of two widely implemented EHR GUIs for critical clinical notes usage tasks. Methods Twelve Internal Medicine resident physicians interacting with one of the two EHR systems (System-1 at Location-A and System-2 at Location-B) were observed by two usability evaluators employing an ethnographic approach. User comments and observer findings were analyzed for two critical tasks: (1) clinical notes entry and (2) related information-seeking tasks. Data were analyzed from two standpoints: (1) usability references categorized by usability evaluators as positive, negative, or equivocal and (2) usability impact of each feature measured through a 7-point severity rating scale. Findings were also validated by user responses to a post observation questionnaire. Results For clinical notes entry, System-1 surpassed System-2 with more positive (26% vs. 12%) than negative (12% vs. 34%) usability references. Greatest impact features on EHR usability (severity score pertaining to each feature) for clinical notes entry were: autopopulation (6), screen options (5.5), communication (5), copy pasting (4.5), error prevention (4.5), edit ability (4), and dictation and transcription (3.5). Both systems performed equally well on information-seeking tasks and features with greatest impacts on EHR usability were navigation for notes (7) and others (e.g., looking for ancillary data; 5.5). Ethnographic observations were supported by follow-up questionnaire responses. Conclusion This study provides usability-specific insights to inform future, improved, EHR interface that is better aligned with UCD approach.

  7. Designing Telemedicine Systems for Geriatric Patients: A Review of the Usability Studies.

    Science.gov (United States)

    Narasimha, Shraddhaa; Madathil, Kapil Chalil; Agnisarman, Sruthy; Rogers, Hunter; Welch, Brandon; Ashok, Aparna; Nair, Aswathi; McElligott, James

    2017-06-01

    One area where telemedicine may prove to be highly effective is in providing medical care to the geriatric population, an age group predicted to account for 20% of the population in the near future. However, even though telemedicine has certain advantages, the usability of these systems with this population merits investigation. This article reviews the literature published from 2000 to 2016 with the goal of analyzing the characteristics of usability-related studies conducted using geriatric participants and the subsequent usability challenges identified. Articles were found using Web of Knowledge and PubMed citation indexing portals using the keywords (1) Telemedicine* AND Geriatrics* (2) Telemedicine* AND Usability* (3) Telemedicine* AND Usability* AND Older Adults*. A total of 297 articles were obtained from the initial search. After further detailed screening, 16 articles were selected for review based on the inclusion criteria. Of these, 60% of the studies focused on the overall usability of telemedicine systems; 6.25% focused on the usability of a telepresence robot; 12.5% compared a face-to-face medical consultation with the use of telemedicine systems, and 25% focused on the study of other aspects of telemedicine in addition to its usability. Findings reported in the studies included high patient satisfaction with telemedicine in 31.25%, whereas another 31.25% indicated a high acceptance of this method of medical consultation. Care coordination in 6.25% of the studies; confidence in telemedicine in 6.25%; trust, privacy, and reliability in 6.25%; and increased convenience when compared to personal visits in 18.75% were also reported. This review suggests limited research providing scientifically valid and reproducible usability evaluation at various stages of telemedicine system development. Telemedicine system designers need to consider the age-related issues in cognition, perception, and behavior of geriatric patients while designing telemedicine

  8. Development of a Wearable Cardiac Monitoring System for Behavioral Neurocardiac Training: A Usability Study.

    Science.gov (United States)

    Uddin, Akib A; Morita, Plinio P; Tallevi, Kevin; Armour, Kevin; Li, John; Nolan, Robert P; Cafazzo, Joseph A

    2016-04-22

    Elevated blood pressure is one of the main risk factors for death globally. Behavioral neurocardiac training (BNT) is a complementary approach to blood pressure and stress management that is intended to exercise the autonomic reflexes, improve stress recovery, and lower blood pressure. BNT involves cognitive-behavioral therapy with a paced breathing technique and heart rate variability biofeedback. BNT is limited to in-clinic delivery and faces an accessibility barrier because of the need for clinical oversight and the use of complex monitoring tools. The objective of this project was to design, develop, and evaluate a wearable electrocardiographic (ECG) sensor system for the delivery of BNT in a home setting. The wearable sensor system, Beat, consists of an ECG sensor and a mobile app. It was developed iteratively using the principles of test-driven Agile development and user-centered design. A usability study was conducted at Toronto General Hospital to evaluate feasibility and user experience and identify areas of improvement. The Beat sensor was designed as a modular patch to be worn on the user's chest and uses standard ECG electrodes. It streams a single-lead ECG wirelessly to a mobile phone using Bluetooth Low Energy. The use of small, low-power electronics, a low device profile, and a tapered enclosure allowed for a device that can be unobtrusively worn under clothing. The sensor was designed to operate with a mobile app that guides users through the BNT exercises to train them to a slow-paced breathing technique for stress recovery. The BNT app uses the ECG captured by the sensor to provide heart rate variability biofeedback in the form of a real-time heart rate waveform to complement and reinforce the impact of the training. Usability testing (n=6) indicated that the overall response to the design and user experience of the system was perceived positively. All participants indicated that the system had a positive effect on stress management and that they

  9. 77 FR 8217 - Evaluating the Usability of Electronic Health Record (EHR) Systems

    Science.gov (United States)

    2012-02-14

    ... usability of health information technology (HIT) systems, EHRs in particular, and performance-oriented user... the usability of health information technology (HIT) systems. NIST research is designed to: (1... DEPARTMENT OF COMMERCE National Institute of Standards and Technology [Docket No. 120123059-2058...

  10. Comparison of two heuristic evaluation methods for evaluating the usability of health information systems.

    Science.gov (United States)

    Khajouei, Reza; Hajesmaeel Gohari, Sadrieh; Mirzaee, Moghaddameh

    2018-04-01

    In addition to following the usual Heuristic Evaluation (HE) method, the usability of health information systems can also be evaluated using a checklist. The objective of this study is to compare the performance of these two methods in identifying usability problems of health information systems. Eight evaluators independently evaluated different parts of a Medical Records Information System using two methods of HE (usual and with a checklist). The two methods were compared in terms of the number of problems identified, problem type, and the severity of identified problems. In all, 192 usability problems were identified by two methods in the Medical Records Information System. This was significantly higher than the number of usability problems identified by the checklist and usual method (148 and 92, respectively) (p information systems. The results demonstrated that the checklist method had significantly better performance in terms of the number of identified usability problems; however, the performance of the usual method for identifying problems of higher severity was significantly better. Although the checklist method can be more efficient for less experienced evaluators, wherever usability is critical, the checklist should be used with caution in usability evaluations. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Agents and wearables : usability in the COMRIS system

    NARCIS (Netherlands)

    Haan, de G.; Terken, J.M.B.

    2001-01-01

    This paper discusses usability research concerning a wearable system for spoken advice: a field experiment to investigate key concepts, a laboratory experiment to investigate interaction design, and field trials to evaluate the system. Conclusions are drawn about designing wearable appliances.

  12. Health system guidance appraisal--concept evaluation and usability testing.

    Science.gov (United States)

    Ako-Arrey, Denis E; Brouwers, Melissa C; Lavis, John N; Giacomini, Mita K

    2016-01-05

    Health system guidance (HSG) provides recommendations aimed to address health system challenges. However, there is a paucity of methods to direct, appraise, and report HSG. Earlier research identified 30 candidate criteria (concepts) that can be used to evaluate the quality of HSG and guide development and reporting requirements. The objective of this paper was to describe two studies aimed at evaluating the importance of these 30 criteria, design a draft HSG appraisal tool, and test its usability. This study involved a two-step survey process. In step 1, respondents rated the 30 concepts for appropriateness to, relevance to, and priority for health system decisions and HSG. This led to a draft tool. In step 2, respondents reviewed HSG documents, appraised them using the tool, and answered a series of questions. Descriptive analyses were computed. Fifty participants were invited in step 1, and we had a response rate of 82 %. The mean response rates for each concept within each survey question were universally favorable. There was also an overall agreement about the need for a high-quality tool to systematically direct the development, appraisal, and reporting of HSG. Qualitative feedback and a consensus process by the team led to refinements to some of the concepts and the creation of a beta (draft) version of the HSG tool. In step 2, 35 participants were invited and we had a response rate of 74 %. Exploratory analyses showed that the quality of the HSGs reviewed varied as a function of the HSG item and the specific document assessed. A favorable consensus was reached with participants agreeing that the HSG items were easy to understand and easy to apply. Moreover, the overall agreement was high for the usability of the tool to systematically direct the development (85 %), appraisal (92 %), and reporting (81 %) of HSG. From this process, version 1.0 of the HSG appraisal tool was generated complete with 32 items (and their descriptions) and 4 domains. The final

  13. Combinations of Methods for Collaborative Evaluation of the Usability of Interactive Software Systems

    Directory of Open Access Journals (Sweden)

    Andrés Solano

    2016-01-01

    Full Text Available Usability is a fundamental quality characteristic for the success of an interactive system. It is a concept that includes a set of metrics and methods in order to obtain easy-to-learn and easy-to-use systems. Usability Evaluation Methods, UEM, are quite diverse; their application depends on variables such as costs, time availability, and human resources. A large number of UEM can be employed to assess interactive software systems, but questions arise when deciding which method and/or combination of methods gives more (relevant information. We propose Collaborative Usability Evaluation Methods, CUEM, following the principles defined by the Collaboration Engineering. This paper analyzes a set of CUEM conducted on different interactive software systems. It proposes combinations of CUEM that provide more complete and comprehensive information about the usability of interactive software systems than those evaluation methods conducted independently.

  14. Usability of Low-Cost Android Data Collection System for Community-Based Participatory Research.

    Science.gov (United States)

    Salihu, Hamisu M; Salinas-Miranda, Abraham; Turner, DeAnne; King, Lindsey; Paothong, Arnut; Austin, Deborah; Berry, Estrellita Lo

    2016-01-01

    Android tablet computers can be valuable tools for data collection, but their usability has not been evaluated in community-based participatory research (CBPR). This article examines the usability of a low-cost bilingual touchscreen computerized survey system using Android tablets, piloted with a sample of 201 community residents in Tampa, Florida, from November 2013 to March 2014. Needs assessment questions were designed with the droidSURVEY software, and deployed using Android tablet computers. In addition, participants were asked questions about system usability. The mean system usability was 77.57 ± 17.66 (range, 0-100). The mean completion time for taking the 63 survey questions in the needs assessment was 23.11 ± 9.62 minutes. The survey completion rate was optimal (100%), with only 6.34% missingness per variable. We found no sociodemographic differences in usability scores. Our findings indicate that Android tablets could serve as useful tools in CBPR studies.

  15. The cultural evolution of human communication systems in different sized populations: usability trumps learnability.

    Science.gov (United States)

    Fay, Nicolas; Ellison, T Mark

    2013-01-01

    This study examines the intergenerational transfer of human communication systems. It tests if human communication systems evolve to be easy to learn or easy to use (or both), and how population size affects learnability and usability. Using an experimental-semiotic task, we find that human communication systems evolve to be easier to use (production efficiency and reproduction fidelity), but harder to learn (identification accuracy) for a second generation of naïve participants. Thus, usability trumps learnability. In addition, the communication systems that evolve in larger populations exhibit distinct advantages over those that evolve in smaller populations: the learnability loss (from the Initial signs) is more muted and the usability benefits are more pronounced. The usability benefits for human communication systems that evolve in a small and large population is explained through guided variation reducing sign complexity. The enhanced performance of the communication systems that evolve in larger populations is explained by the operation of a content bias acting on the larger pool of competing signs. The content bias selects for information-efficient iconic signs that aid learnability and enhance usability.

  16. Usability Prediction & Ranking of SDLC Models Using Fuzzy Hierarchical Usability Model

    Science.gov (United States)

    Gupta, Deepak; Ahlawat, Anil K.; Sagar, Kalpna

    2017-06-01

    Evaluation of software quality is an important aspect for controlling and managing the software. By such evaluation, improvements in software process can be made. The software quality is significantly dependent on software usability. Many researchers have proposed numbers of usability models. Each model considers a set of usability factors but do not cover all the usability aspects. Practical implementation of these models is still missing, as there is a lack of precise definition of usability. Also, it is very difficult to integrate these models into current software engineering practices. In order to overcome these challenges, this paper aims to define the term `usability' using the proposed hierarchical usability model with its detailed taxonomy. The taxonomy considers generic evaluation criteria for identifying the quality components, which brings together factors, attributes and characteristics defined in various HCI and software models. For the first time, the usability model is also implemented to predict more accurate usability values. The proposed system is named as fuzzy hierarchical usability model that can be easily integrated into the current software engineering practices. In order to validate the work, a dataset of six software development life cycle models is created and employed. These models are ranked according to their predicted usability values. This research also focuses on the detailed comparison of proposed model with the existing usability models.

  17. Multifunctional systems in vehicles:a usability evaluation

    OpenAIRE

    Rydström, Annie; Bengtsson, Peter; Grane, Camilla; Broström, Robert; Agardh, Johannes; Nilsson, Jennie

    2005-01-01

    Car Human-Machine Interaction (HMI) is becoming increasingly complex as the extension of functionality necessitates new interface concepts. Various multifunctional systems operated by haptic rotary switches, touch screen, and voice control have been developed. A usability study of multifunctional systems available on the market was carried out to evaluate and compare different manual interaction principles. The systems used in the study were the BMW iDrive and the Audi MMI, both operated by a...

  18. Integrated System Validation Usability Questionnaire: Computerized Procedures

    International Nuclear Information System (INIS)

    Garcés, Ma. I.; Torralba, B.

    2015-01-01

    The Research and Development (R&D) project on “Theoretical and Methodological Approaches to Integrated System Validation of Control Rooms, 2014-2015”, in which the research activities described in this report are framed, has two main objectives: to develop the items for an usability methodology conceived as a part of the measurement framework for performance-based control room evaluation that the OECD Halden Reactor Project will test in the experiments planned for 2015; and the statistical analysis of the data generated in the experimental activities of the Halden Man-Machine Laboratory (HAMMLAB) facility, with previous usability questionnaires, in 2010 and 2011. In this report, the procedure designed to meet the first goal of the project is described, in particular, the process followed to identify the items related to operating procedures, both computer and paper-based, one of the elements to be included in the usability questionnaire. Three phases are performed, in the first one, the approaches developed by the United States Nuclear Regulatory Commission, NRC, are reviewed, the models used by the nuclear industry and their technical support organizations, mainly, the Electric Power Research Institute, EPRI, are analyzed, and scientist advances are also explored. In the remaining stages, general and specific guidelines for computerized and paper-based procedures are compared and criteria for the preliminary selection of the items that should be incorporated into the usability questionnaire are defined. This proposal will be reviewed and adapted by the Halden Reactor Project to the design of the specific experiments performed in HAMLAB.

  19. The cultural evolution of human communication systems in different sized populations: usability trumps learnability.

    Directory of Open Access Journals (Sweden)

    Nicolas Fay

    Full Text Available This study examines the intergenerational transfer of human communication systems. It tests if human communication systems evolve to be easy to learn or easy to use (or both, and how population size affects learnability and usability. Using an experimental-semiotic task, we find that human communication systems evolve to be easier to use (production efficiency and reproduction fidelity, but harder to learn (identification accuracy for a second generation of naïve participants. Thus, usability trumps learnability. In addition, the communication systems that evolve in larger populations exhibit distinct advantages over those that evolve in smaller populations: the learnability loss (from the Initial signs is more muted and the usability benefits are more pronounced. The usability benefits for human communication systems that evolve in a small and large population is explained through guided variation reducing sign complexity. The enhanced performance of the communication systems that evolve in larger populations is explained by the operation of a content bias acting on the larger pool of competing signs. The content bias selects for information-efficient iconic signs that aid learnability and enhance usability.

  20. The impact of usability reports and user test observations on developers understanding of usability data

    DEFF Research Database (Denmark)

    Høegh, Rune Thaarup; Nielsen, Christian Monrad; Pedersen, Michael Bach

    2006-01-01

    of the system. This article presents results from an exploratory study of 2 ways of providing feedback from a usability evaluation: observation of user tests and reading usability reports. A case study and a field experiment were used to explore how observation and usability reports impact developers......' understanding of usability data. The results indicate that observation of user tests facilitated a rich understanding of usability problems and created empathy with the users and their work. The usability report had a strong impact on the developers' understanding of specific usability problems and supported...

  1. Measuring the Usability of Augmented Reality e-Learning Systems: A User-Centered Evaluation Approach

    Science.gov (United States)

    Pribeanu, Costin; Balog, Alexandru; Iordache, Dragoş Daniel

    The development of Augmented Reality (AR) systems is creating new challenges and opportunities for the designers of e-learning systems. The mix of real and virtual requires appropriate interaction techniques that have to be evaluated with users in order to avoid usability problems. Formative usability aims at finding usability problems as early as possible in the development life cycle and is suitable to support the development of such novel interactive systems. This work presents an approach to the user-centered usability evaluation of an e-learning scenario for Biology developed on an Augmented Reality educational platform. The evaluation has been carried on during and after a summer school held within the ARiSE research project. The basic idea was to perform usability evaluation twice. In this respect, we conducted user testing with a small number of students during the summer school in order to get a fast feedback from users having good knowledge in Biology. Then, we repeated the user testing in different conditions and with a relatively larger number of representative users. In this paper we describe both experiments and compare the usability evaluation results.

  2. Personal Usability Constructs

    DEFF Research Database (Denmark)

    Hertzum, Morten; Clemmensen, Torkil; Hornbæk, Kasper

    2011-01-01

    Whereas the concept of usability is predominantly defined analytically, people relate to systems through personal usability constructs. Based on 48 repertory-grid interviews, this study investigates how such personal constructs are affected by two factors crucial to the international development...

  3. Usability evaluation of the interactive Personal Patient Profile-Prostate decision support system with African American men.

    Science.gov (United States)

    Jaja, Cheedy; Pares-Avila, Jose; Wolpin, Seth; Berry, Donna

    2010-04-01

    The Personal Patient Profile-Prostate (P4) program is an interactive Web-based decision support system that provides men with localized prostate cancer customized education and coaching with which to make the best personal treatment decision. This study assessed functionality and usability of the P4 program and identified problems in user-computer interaction in a sample of African American men. Usability testing was conducted with 12 community-dwelling African American adult men. The health status of participants was not known or collected by the research team. Each participant worked with the P4 program and provided simultaneous feedback using the "think aloud" technique. Handwritten field notes were collated and assigned to 3 standard coded categories. Aspects of P4 program usability was made based on common issues in the assigned categories. Summary statistics were derived for types and frequency of usability issues noted in the coded data. Twelve participants reported a total of 122 usability comments, with a mean of 9 usability comments. The most common usability issue by participant was completeness of information content, which comprised 53 (43%) of the total issues. Comprehensibility of text and graphics was second, comprising 51 (42%) of the total issues. This study provided initial inventory of usability issues for community African American men that may potentially interfere with application of the P4 system in the community setting and overall system usability, confirming the need for usability testing of a culturally appropriate Internet-based decision support system before community application.

  4. Usability in Scientific Databases

    Directory of Open Access Journals (Sweden)

    Ana-Maria Suduc

    2012-07-01

    Full Text Available Usability, most often defined as the ease of use and acceptability of a system, affects the users' performance and their job satisfaction when working with a machine. Therefore, usability is a very important aspect which must be considered in the process of a system development. The paper presents several numerical data related to the history of the scientific research of the usability of information systems, as it is viewed in the information provided by three important scientific databases, Science Direct, ACM Digital Library and IEEE Xplore Digital Library, at different queries related to this field.

  5. Usability Evaluation of a Video Conferencing System in a University’s Classroom

    DEFF Research Database (Denmark)

    Khalid, Md. Saifuddin; Hossan, Md. Iqbal

    2016-01-01

    -Time Communications (e.g. Google Hangout, Adobe Connect, Cisco WebEx, and appear.in), and dedicated (e.g. Polycom). There is a lack of empirical study on usability evaluation of the interactive systems in educational contexts. This study identifies usability errors and measures user satisfaction of a dedicated VCS...

  6. Design and validation of a questionnaire to evaluate the usability of computerized critical care information systems.

    Science.gov (United States)

    von Dincklage, Falk; Lichtner, Gregor; Suchodolski, Klaudiusz; Ragaller, Maximilian; Friesdorf, Wolfgang; Podtschaske, Beatrice

    2017-08-01

    The implementation of computerized critical care information systems (CCIS) can improve the quality of clinical care and staff satisfaction, but also holds risks of disrupting the workflow with consecutive negative impacts. The usability of CCIS is one of the key factors determining their benefits and weaknesses. However, no tailored instrument exists to measure the usability of such systems. Therefore, the aim of this study was to design and validate a questionnaire that measures the usability of CCIS. Following a mixed-method design approach, we developed a questionnaire comprising two evaluation models to assess the usability of CCIS: (1) the task-specific model rates the usability individually for several tasks which CCIS could support and which we derived by analyzing work processes in the ICU; (2) the characteristic-specific model rates the different aspects of the usability, as defined by the international standard "ergonomics of human-system interaction". We tested validity and reliability of the digital version of the questionnaire in a sample population. In the sample population of 535 participants both usability evaluation models showed a strong correlation with the overall rating of the system (multiple correlation coefficients ≥0.80) as well as a very high internal consistency (Cronbach's alpha ≥0.93). The novel questionnaire is a valid and reliable instrument to measure the usability of CCIS and can be used to study the influence of the usability on their implementation benefits and weaknesses.

  7. Usability evaluation of healthcare information systems: comparison of methods and classification of usability problems

    NARCIS (Netherlands)

    Khajouei, R.

    2011-01-01

    In ziekenhuizen wordt steeds meer gebruik gemaakt van informatiesystemen, maar de usability laat vaak te wensen over. Reza Khajouei testte twee methodes om de usability te beoordelen. Hij constateert dat beide methoden ongeveer evenveel, maar verschillende problemen aan het licht brengen. Uit een

  8. Usability styles of the plant safety monitoring and assesment system, PLASMA

    International Nuclear Information System (INIS)

    Green, M.; Hornaes, A.; Hulsund, J.E.; Vegh, J.; Major, Cs.; Lipcsei, S.; Borbely, S.

    2001-01-01

    Development of the PLASMA (Plant Safety Monitoring and Assessment) system was started in 1998 in the framework of an international Research and Development project supported by OECD/NEA. The objective of this project was to develop an on-line information system to support VVER reactor operators during the execution of symptom-based Emergency Operating Procedures (EOPs), with the Paks NPP in Hungary as the target plant. In connection with the installation of the PLASMA system at Paks NPP it was decided to perform a usability study of the system through interviewing NPP operators after they had completed a short training course on the PLASMA system and used it during a validation and training session in the training simulator at Paks. This report describes the basic process used in preparations and execution of the usability studies, including methods for gathering information and analysis of the findings from the validation. As a general conclusion from the usability studies it can be stated that the PLASMA system received very favourable ratings from the operators. User satisfaction was generally rated highly and comments from operators were positive. This is particularly encouraging considering the relatively short introduction and experience that the operators had with the system at the time of the-evaluation. (Author)

  9. Usability evaluation of in-housed developed ERP system

    Science.gov (United States)

    Faisal, Chaudhry Muhammad Nadeem; Shakeel Faridi, Muhammad; Javed, Zahid

    2011-10-01

    Enterprise Resource Planning systems are the combination of different business IS (Information System) applications that are designed according to the organization requirements. Generally ERP systems are suffering from complex user interface issues. Recent research shows that there is a need for improvement concerning, the user interface from their perspectives. In order to design the software applications that are easy to use, memorize and apply to new problems, we must know the users philosophy and something about learning, reminiscence and problems solving. The Usability engineering is the only way to study the deeds of users while interacting with ERP (Enterprise Resource & Planning). This paper will focus on the users' experiences view of financial module in ERP system. The HCI research method, explicitly survey questionnaire method was adopted to gather users understanding in order to evaluate the selected modules for in-housed ERP system. The study involved group of users from two industries, the results can not be generalized as a whole. The study was first time successfully applied Usability evaluation on in-housed ERP in local industry (Masood Textile Mills, Interloop Ltd) in Pakistan. The results may hopefully opened-up an area of research and methodology that could provide considerable further benefits to Industry in developments of Industrial information systems.

  10. Towards an empirical method of usability testing of system parts : a methodological study

    NARCIS (Netherlands)

    Brinkman, W.P.; Haakma, R.; Bouwhuis, D.G.

    2007-01-01

    Current usability evaluation methods are essentially holistic in nature. However, engineers that apply a component-based software engineering approach might also be interested in understanding the usability of individual parts of an interactive system. This paper examines the efficiency dimension of

  11. How do Usability Professionals Construe Usability?

    DEFF Research Database (Denmark)

    Hertzum, Morten; Clemmensen, Torkil

    2012-01-01

    distinguishing it from user experience. On the basis of repertory-grid interviews with 24 Chinese, Danish, and Indian usability professionals we find that they make use of more utilitarian than experiential, i.e. user-experience related, constructs. This indicates that goal-related performance is central......’ constructs, particularly their experiential constructs, go considerably beyond ISO 9241 usability, indicating a discrepancy between this definition of usability and the thinking of the professionals concerned with delivering usability. Finally, usability is construed rather similarly across the three...

  12. Usability in Government Systems User Experience Design for Citizens and Public Servants

    CERN Document Server

    Buie, Elizabeth

    2012-01-01

    As a usability specialist or interaction designer working with the government, or as a government or contractor professional involved in specifying, procuring, or managing system development, you need this book. Editors Elizabeth Buie and Dianne Murray have brought together over 30 experts to outline practical advice to both usability specialists and government technology professionals and managers. Working with internal and external government systems is a unique and difficult task because of of the sheer magnitude of the audience for external systems (the entire population of a country, a

  13. Integrated System Validation Usability Questionnaire: Information Display Element

    International Nuclear Information System (INIS)

    Garcés, Ma. I.; Torralba, B.

    2015-01-01

    The Research and Development (R&D) project on “Theoretical and Methodological Approaches to Integrated System Validation of Control Rooms, 2014-2015”, in which the research activities described in this report are framed, has two main objectives: to develop the items for an usability methodology conceived as a part of the measurement framework for performance-based control room evaluation that the OECD Halden Reactor Project will test in the experiments planned for 2015; and the statistical analysis of the data generated in the experimental activities of the Halden Man-Machine Laboratory (HAMMLAB) facility, with previous usability questionnaires, in 2010 and 2011. In this report, the procedure designed to meet the first goal of the project is described, in particular, the process followed to identify the items related to information displays, one of the elements to be included in the usability questionnaire. Three phases are performed, in the first one, the approaches developed by the United States Nuclear Regulatory Commission, NRC, are reviewed and the models proposed by the nuclear energy industry and their technical support organizations, mainly, the United States Electric Power Research Institute, EPRI, are analyzed. In the remaining stages, general and specific guidelines for information displays, in particular, display pages, formats, elements and data quality and update rate recommendations are compared and criteria for the preliminary selection of the items that should be incorporated into the usability questionnaire are defined. This proposal will be reviewed and adapted by the Halden Reactor Project to the design of the specific experiments performed in HAMMLAB.

  14. Combining usability evaluations to highlight the chain that leads from usability flaws to usage problems and then negative outcomes.

    Science.gov (United States)

    Watbled, Ludivine; Marcilly, Romaric; Guerlinger, Sandra; Bastien, J-M Christian; Beuscart-Zéphir, Marie-Catherine; Beuscart, Régis

    2018-02-01

    Poor usability of health technology is thought to diminish work system performance, increase error rates and, potentially, harm patients. The present study (i) used a combination of usability evaluation methods to highlight the chain that leads from usability flaws to usage problems experienced by users and, ultimately, to negative patient outcomes, and (ii) validated this approach by studying two different discharge summary production systems. To comply with quality guidelines, the process of drafting and sending discharge summaries is increasingly being automated. However, the usability of these systems may modify their impact (or the absence thereof) in terms of production times and quality, and must therefore be evaluated. Here, we applied three successive techniques for usability evaluation (heuristic evaluation, user testing and field observation) to two discharge summary production systems (underpinned by different technologies). The systems' main usability flaws led respectively to an increase in the time need to produce a discharge summary and the risk of patient misidentification. Our results are discussed with regard to the possibility of linking the usability flaws, usage problems and the negative outcomes by successively applying three methods for evaluating usability (heuristic evaluation, user testing and in situ observations) throughout the system development life cycle. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. The significance of a usability evaluation of an emerging laboratory order entry system

    NARCIS (Netherlands)

    Peute, Linda W. P.; Jaspers, Monique W. M.

    2007-01-01

    OBJECTIVES: To assess the usability of an emerging POE system, OM/Lab, for the computer-supported ordering of laboratory tests. We were more specifically interested in the relation of the usability problems detected in the user testing sessions with the order behaviour in terms of efficiency and

  16. Reducing and Sustaining Duplicate Medical Record Creation by Usability Testing and System Redesign.

    Science.gov (United States)

    Khunlertkit, Adjhaporn; Dorissaint, Leonard; Chen, Allen; Paine, Lori; Pronovost, Peter J

    2017-10-25

    Duplicate medical record creation is a common and consequential health care systems error often caused by poor search system usability and inappropriate user training. We conducted two phases of scenario-based usability testing with patient registrars working in areas at risk of generating duplicate medical records. Phase 1 evaluated the existing search system, which led to system redesigns. Phase 2 tested the redesigned system to mitigate potential errors before health system-wide implementation. To evaluate system effectiveness, we compared the monthly potential duplicate medical record rates for preimplementation and postimplementation months. The existing system could not effectively handle a misspelling, which led to failed search and duplicate medical record creation. Using the existing system, 96% of registrars found commonly spelled patient names whereas only 69% successfully found complicated names. Registrars lacked knowledge and usage of a phonetic matching function to assist in misspelling. The new system consistently captured the correct patient regardless of misspelling, but search returned more potential matches, resulting in, on average, 4 seconds longer to select common names. Potential monthly duplicate medical record rate reduced by 38%, from 4% to 2.3% after implementation of the new system, and has sustained at an average of 2.5% for 2 years. Usability testing was an effective method to reveal problems and aid system redesign to deliver a more user friendly system, hence reducing the potential for medical record duplication. Greater standards for usability would ensure that these improvements can be realized before rather than after exposing patients to risks.

  17. Work-domain knowledge in usability evaluation

    DEFF Research Database (Denmark)

    Følstad, Asbjørn; Hornbæk, Kasper

    2010-01-01

    Usability evaluation helps to determine whether interactive systems support users in their work tasks. However, knowledge about those tasks and, more generally, about the work-domain is difficult to bring to bear on the processes and outcome of usability evaluation. One way to include such work......-domain knowledge might be Cooperative Usability Testing, an evaluation method that consists of (a) interaction phases, similar to classic usability testing, and (b) interpretation phases, where the test participant and the moderator discuss incidents and experiences from the interaction phases. We have studied...... whether such interpretation phases improve the relevance of usability evaluations in the development of work-domain specific systems. The study included two development cases. We conclude that the interpretation phases generate additional insight and redesign suggestions related to observed usability...

  18. Physician satisfaction with a critical care clinical information system using a multimethod evaluation of usability.

    Science.gov (United States)

    Hudson, Darren; Kushniruk, Andre; Borycki, Elizabeth; Zuege, Danny J

    2018-04-01

    Physician satisfaction with electronic medical records has often been poor. Usability has frequently been identified as a source for decreased satisfaction. While surveys can identify many issues, and are logistically easier to administer, they may miss issues identified using other methods This study sought to understand the level of physician satisfaction and usability issues associated with a critical care clinical information system (eCritical Alberta) implemented throughout the province of Alberta, Canada. All critical care attending physicians using the system were invited to participate in an online survey. Questions included components of the User Acceptance of Information Technology and Usability Questionnaire as well as free text feedback on system components. Physicians were also invited to participate in a think aloud test using simulated scenarios. The transcribed think aloud text and questionnaire were subjected to textual analysis. 82% of all eligible physicians completed the on-line survey (n = 61). Eight physicians were invited and seven completed the think aloud test. Overall satisfaction with the system was moderate. Usability was identified as a significant factor contributing to satisfaction. The major usability factors identified were system response time and layout. The think aloud component identified additional factors beyond those identified in the on-line survey. This study found a modestly high level of physician satisfaction with a province-wide clinical critical care information system. Usability continues to be a significant factor in physician satisfaction. Using multiple methods of evaluation can capture the benefits of a large sample size and deeper understanding of the issues. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Educational software usability: Artifact or Design?

    Science.gov (United States)

    Van Nuland, Sonya E; Eagleson, Roy; Rogers, Kem A

    2017-03-01

    Online educational technologies and e-learning tools are providing new opportunities for students to learn worldwide, and they continue to play an important role in anatomical sciences education. Yet, as we shift to teaching online, particularly within the anatomical sciences, it has become apparent that e-learning tool success is based on more than just user satisfaction and preliminary learning outcomes-rather it is a multidimensional construct that should be addressed from an integrated perspective. The efficiency, effectiveness and satisfaction with which a user can navigate an e-learning tool is known as usability, and represents a construct which we propose can be used to quantitatively evaluate e-learning tool success. To assess the usability of an e-learning tool, usability testing should be employed during the design and development phases (i.e., prior to its release to users) as well as during its delivery (i.e., following its release to users). However, both the commercial educational software industry and individual academic developers in the anatomical sciences have overlooked the added value of additional usability testing. Reducing learner frustration and anxiety during e-learning tool use is essential in ensuring e-learning tool success, and will require a commitment on the part of the developers to engage in usability testing during all stages of an e-learning tool's life cycle. Anat Sci Educ 10: 190-199. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  20. Usable security history, themes, and challenges

    CERN Document Server

    Garfinkel, Simson

    2014-01-01

    There has been roughly 15 years of research into approaches for aligning research in Human Computer Interaction with computer Security, more colloquially known as ``usable security.'' Although usability and security were once thought to be inherently antagonistic, today there is wide consensus that systems that are not usable will inevitably suffer security failures when they are deployed into the real world. Only by simultaneously addressing both usability and security concerns will we be able to build systems that are truly secure. This book presents the historical context of the work to dat

  1. Usability of clinical decision support system as a facilitator for learning the assistive technology adaptation process.

    Science.gov (United States)

    Danial-Saad, Alexandra; Kuflik, Tsvi; Weiss, Patrice L Tamar; Schreuer, Naomi

    2016-01-01

    The aim of this study was to evaluate the usability of Ontology Supported Computerized Assistive Technology Recommender (OSCAR), a Clinical Decision Support System (CDSS) for the assistive technology adaptation process, its impact on learning the matching process, and to determine the relationship between its usability and learnability. Two groups of expert and novice clinicians (total, n = 26) took part in this study. Each group filled out system usability scale (SUS) to evaluate OSCAR's usability. The novice group completed a learning questionnaire to assess OSCAR's effect on their ability to learn the matching process. Both groups rated OSCAR's usability as "very good", (M [SUS] = 80.7, SD = 11.6, median = 83.7) by the novices, and (M [SUS] = 81.2, SD = 6.8, median = 81.2) by the experts. The Mann-Whitney results indicated that no significant differences were found between the expert and novice groups in terms of OSCAR's usability. A significant positive correlation existed between the usability of OSCAR and the ability to learn the adaptation process (rs = 0.46, p = 0.04). Usability is an important factor in the acceptance of a system. The successful application of user-centered design principles during the development of OSCAR may serve as a case study that models the significant elements to be considered, theoretically and practically in developing other systems. Implications for Rehabilitation Creating a CDSS with a focus on its usability is an important factor for its acceptance by its users. Successful usability outcomes can impact the learning process of the subject matter in general, and the AT prescription process in particular. The successful application of User-Centered Design principles during the development of OSCAR may serve as a case study that models the significant elements to be considered, theoretically and practically. The study emphasizes the importance of close collaboration between the developers and

  2. Expected usability is not a valid indicator of experienced usability

    Directory of Open Access Journals (Sweden)

    Meinald T. Thielsch

    2015-09-01

    Full Text Available Usability is a core construct of website evaluation and inherently defined as interactive. Yet, when analysing first impressions of websites, expected usability, i.e., before use, is of interest. Here we investigate to what extend ratings of expected usability are related to (a experienced usability, i.e., ratings after use, and (b objective usability measures, i.e., task performance. Furthermore, we try to elucidate how ratings of expected usability are correlated to aesthetic judgments. In an experiment, 57 participants submitted expected usability ratings after the presentation of website screenshots in three viewing-time conditions (50, 500, and 10,000 ms and after an interactive task (experienced usability. Additionally, objective usability measures (task completion and duration and subjective aesthetics evaluations were recorded for each website. The results at both the group and individual level show that expected usability ratings are not significantly related either to experienced usability or objective usability measures. Instead, they are highly correlated with aesthetics ratings. Taken together, our results highlight the need for interaction in empirical website usability testing, even when exploring very early usability impressions. In our study, user ratings of expected usability were no valid proxy neither for objective usability nor for experienced website usability.

  3. The Evaluator Effect in Usability Tests

    DEFF Research Database (Denmark)

    Jacobsen, Niels Ebbe; Hertzum, Morten; John, Bonnie E.

    1998-01-01

    Usability tests are applied in industry to evaluate systems and in research as a yardstick for other usability evaluation methods. However, one potential threat to the reliability of usability tests has been left unaddressed: the evaluator effect. In this study, four evaluators analyzed four vide...

  4. Responsibilities in the Usability Requirements Elicitation Process

    Directory of Open Access Journals (Sweden)

    Marianella Aveledo

    2008-12-01

    Full Text Available Like any other software system quality attribute, usability places requirements on software components. In particular, it has been demonstrated that certain usability features have a direct impact throughout the software process. This paper details an approach that looks at how to deal with certain usability features in the early software development stages. In particular, we consider usability features as functional usability requirements using patterns that have been termed usability patterns to elicit requirements. Additionally, we clearly establish the responsibilities of all the players at the usability requirements elicitation stage.

  5. Usability Study of a Wireless Monitoring System among Alzheimer’s Disease Elderly Population

    Directory of Open Access Journals (Sweden)

    Stefano Abbate

    2014-01-01

    Full Text Available Healthcare technologies are slowly entering into our daily lives, replacing old devices and techniques with newer intelligent ones. Although they are meant to help people, the reaction and willingness to use such new devices by the people can be unexpected, especially among the elderly. We conducted a usability study of a fall monitoring system in a long-term nursing home. The subjects were the elderly with advanced Alzheimer’s disease. The study presented here highlights some of the challenges faced in the use of wearable devices and the lessons learned. The results gave us useful insights, leading to ergonomics and aesthetics modifications to our wearable systems that significantly improved their usability and acceptance. New evaluating metrics were designed for the performance evaluation of usability and acceptability.

  6. An Iterative, Mixed Usability Approach Applied to the Telekit System from the Danish TeleCare North Trial

    Science.gov (United States)

    Schaarup, Clara; Hejlesen, Ole Kristian

    2016-01-01

    Objective. The aim of the present study is to evaluate the usability of the telehealth system, coined Telekit, by using an iterative, mixed usability approach. Materials and Methods. Ten double experts participated in two heuristic evaluations (HE1, HE2), and 11 COPD patients attended two think-aloud tests. The double experts identified usability violations and classified them into Jakob Nielsen's heuristics. These violations were then translated into measurable values on a scale of 0 to 4 indicating degree of severity. In the think-aloud tests, COPD participants were invited to verbalise their thoughts. Results. The double experts identified 86 usability violations in HE1 and 101 usability violations in HE2. The majority of the violations were rated in the 0–2 range. The findings from the think-aloud tests resulted in 12 themes and associated examples regarding the usability of the Telekit system. The use of the iterative, mixed usability approach produced both quantitative and qualitative results. Conclusion. The iterative, mixed usability approach yields a strong result owing to the high number of problems identified in the tests because the double experts and the COPD participants focus on different aspects of Telekit's usability. This trial is registered with Clinicaltrials.gov, NCT01984840, November 14, 2013. PMID:27974888

  7. Evaluating the parent-adolescent communication toolkit: Usability and preliminary content effectiveness of an online intervention.

    Science.gov (United States)

    Toombs, Elaine; Unruh, Anita; McGrath, Patrick

    2018-01-01

    This study aimed to assess the Parent-Adolescent Communication Toolkit, an online intervention designed to help improve parent communication with their adolescents. Participant preferences for two module delivery systems (sequential and unrestricted module access) were identified. Usability assessment of the PACT intervention was completed using pre-test and posttest comparisons. Usability data, including participant completion and satisfaction ratings were examined. Parents ( N  =   18) of adolescents were randomized to a sequential or unrestricted chapter access group. Parent participants completed pre-test measures, the PACT intervention and posttest measures. Participants provided feedback for the intervention to improve modules and provided usability ratings. Adolescent pre- and posttest ratings were evaluated. Usability ratings were high and parent feedback was positive. The sequential module access groups rated the intervention content higher and completed more content than the unrestricted chapter access group, indicating support for the sequential access design. Parent mean posttest communication scores were significantly higher ( p  Communication Toolkit has potential to improve parent-adolescent communication but further effectiveness assessment is required.

  8. Does Usability Matter? An Analysis of the Impact of Usability on Technology Acceptance in ERP Settings

    Directory of Open Access Journals (Sweden)

    Brenda M Scholtz

    2016-11-01

    Full Text Available Though the field of management information systems, as a sector and a discipline, is the inventor of many guidelines and models, it appears to be a slow runner on practical implications of interface usability. This usability can influence end users’ attitude and behavior to use IT. The purpose of this paper was to examine the interface usability of a popular Enterprise Resource Planning (ERP software system, SAP, and to identify related issues and implications to the Technology Acceptance Model (TAM. A survey was conducted of 112 SAP ERP users from an organization in the heavy metal industry in Bangladesh. The partial least squares technique was used to analyze the survey data. The survey findings empirically confirmed that interface usability has a significant impact on users’ perceptions of usefulness and ease of use which ultimately affects attitudes and intention to use the ERP software. The research model extends the TAM by incorporating three criteria of interface usability. It is the first known study to investigate usability criteria as an extension of TAM.

  9. Three Contexts for Evaluating Organizational Usability

    DEFF Research Database (Denmark)

    Hertzum, Morten

    2018-01-01

    Organizational usability is about the match between the user and the system, between the organization and the system, and between the environment and the system. While the first of these matches can, to a large extent, be evaluated in the lab, the two others cannot. Organizational usability must......, provide a brief example, and discuss the challenges it presents. To strengthen the focus on evaluation in the three contexts we propose the measurement of specified effects, combined with a sensitivity toward emergent effects. Incorporating effects in the evaluation of organizational usability makes...

  10. Low-Cost Rapid Usability Testing: Its Application in Both Product Development and System Implementation.

    Science.gov (United States)

    Kushniruk, Andre; Borycki, Elizabeth

    2017-01-01

    In recent years there has been considerable discussion around the need for certification and regulation of healthcare information technology (IT). In particular, the usability of the products being developed needs to be evaluated. This has included the application of standards designed to ensure the process of system development is user-centered and takes usability into consideration while a product is being developed. In addition to this, in healthcare, organizations in the United States and Europe have also addressed the need and requirement for product certification. However, despite these efforts there are continued reports of unusable and unsafe implementations. In this paper we discuss the need to not only include (and require) usability testing in the one-time development process of health IT products (such as EHRs), but we also argue for the need to additionally develop specific usability standards and requirements for usability testing during the implementation of vendor products (i.e. post product development) in healthcare settings. It is further argued that health IT products that may have been certified regarding their development process will still require application of usability testing in the process of implementing them in real hospital settings in order to ensure usability and safety. This is needed in order to ensure that the final result of both product development and implementation processes take into account and apply the latest usability principles and methods.

  11. Testing the usability of a personalized system: comparing the use of interviews, questionnaires and thinking -aloud

    NARCIS (Netherlands)

    van Velsen, Lex Stefan; van der Geest, Thea; Klaassen, R.F.

    2007-01-01

    Personalized systems present each user with tailored content or output. Testing the usability of such a system must take some specific usability issues and the suitability of the personalized output into account. In this study, we evaluated a personalized search engine to compare the use of

  12. An evaluation of patients' experienced usability of a diabetes mHealth system using a multi-method approach.

    Science.gov (United States)

    Georgsson, Mattias; Staggers, Nancy

    2016-02-01

    mHealth systems are becoming more common to aid patients in their diabetes self-management, but recent studies indicate a need for thorough evaluation of patients' experienced usability. Current evaluations lack a multi-method design for data collection and structured methods for data analyses. The purpose of this study was to provide a feasibility test of a multi-method approach for both data collection and data analyses for patients' experienced usability of a mHealth system for diabetes type 2 self-management. A random sample of 10 users was selected from a larger clinical trial. Data collection methods included user testing with eight representative tasks and Think Aloud protocol, a semi-structured interview and a questionnaire on patients' experiences using the system. The Framework Analysis (FA) method and Usability Problem Taxonomy (UPT) were used to structure, code and analyze the results. A usability severity rating was assigned after classification. The combined methods resulted in a total of 117 problems condensed into 19 usability issues with an average severity rating of 2.47 or serious. The usability test detected 50% of the initial usability problems, followed by the post-interview at 29%. The usability test found 18 of 19 consolidated usability problems while the questionnaire uncovered one unique issue. Patients experienced most usability problems (8) in the Glucose Readings View when performing complex tasks such as adding, deleting, and exporting glucose measurements. The severity ratings were the highest for the Glucose Diary View, Glucose Readings View, and Blood Pressure View with an average severity rating of 3 (serious). Most of the issues were classified under the artifact component of the UPT and primary categories of Visualness (7) and Manipulation (6). In the UPT task component, most issues were in the primary category Task-mapping (12). Multiple data collection methods yielded a more comprehensive set of usability issues. Usability

  13. A Longitudinal Study of Usability in Health Care

    DEFF Research Database (Denmark)

    Kjeldskov, Jesper; Skov, Mikael B.; Stage, Jan

    2010-01-01

    We report from a longitudinal laboratory-based usability evaluation of a health care information system. The purpose of the study was to inquire into the nature of usability problems experienced by novice and expert users, and to see to what extend usability problems of a health care information...... system may or may not disappear over time, as the nurses get more familiar with it-if time heals poor design? As our method for studying this, we conducted a longitudinal study with two key studies. A usability evaluation was conducted with novice users when an electronic patient record system was being......, we discuss implications for evaluating usability in health care....

  14. Interface design recommendations for computerised clinical audit and feedback: Hybrid usability evidence from a research-led system.

    Science.gov (United States)

    Brown, Benjamin; Balatsoukas, Panos; Williams, Richard; Sperrin, Matthew; Buchan, Iain

    2016-10-01

    Audit and Feedback (A&F) is a widely used quality improvement technique that measures clinicians' clinical performance and reports it back to them. Computerised A&F (e-A&F) system interfaces may consist of four key components: (1) Summaries of clinical performance; (2) Patient lists; (3) Patient-level data; (4) Recommended actions. There is a lack of evidence regarding how to best design e-A&F interfaces; establishing such evidence is key to maximising usability, and in turn improving patient safety. To evaluate the usability of a novel theoretically-informed and research-led e-A&F system for primary care (the Performance Improvement plaN GeneratoR: PINGR). (1) Describe PINGR's design, rationale and theoretical basis; (2) Identify usability issues with PINGR; (3) Understand how these issues may interfere with the cognitive goals of end-users; (4) Translate the issues into recommendations for the user-centred design of e-A&F systems. Eight experienced health system evaluators performed a usability inspection using an innovative hybrid approach consisting of five stages: (1) Development of representative user tasks, Goals, and Actions; (2) Combining Heuristic Evaluation and Cognitive Walkthrough methods into a single protocol to identify usability issues; (3) Consolidation of issues; (4) Severity rating of consolidated issues; (5) Analysis of issues according to usability heuristics, interface components, and Goal-Action structure. A final list of 47 issues were categorised into 8 heuristic themes. The most error-prone heuristics were 'Consistency and standards' (13 usability issues; 28% of the total) and 'Match between system and real world' (n=10, 21%). The recommended actions component of the PINGR interface had the most usability issues (n=21, 45%), followed by patient-level data (n=5, 11%), patient lists (n=4, 9%), and summaries of clinical performance (n=4, 9%). The most error-prone Actions across all user Goals were: (1) Patient selection from a list; (2) Data

  15. Human Factors in the Large: Experiences from Denmark, Finland and Canada in Moving Towards Regional and National Evaluations of Health Information System Usability

    Science.gov (United States)

    Kaipio, J.; Nieminen, M.; Hyppönen, H.; Lääveri, T.; Nohr, C.; Kanstrup, A. M.; Berg Christiansen, M.; Kuo, M.-H.; Borycki, E.

    2014-01-01

    Summary Objectives The objective of this paper is to explore approaches to understanding the usability of health information systems at regional and national levels. Methods Several different methods are discussed in case studies from Denmark, Finland and Canada. They range from small scale qualitative studies involving usability testing of systems to larger scale national level questionnaire studies aimed at assessing the use and usability of health information systems by entire groups of health professionals. Results It was found that regional and national usability studies can complement smaller scale usability studies, and that they are needed in order to understand larger trends regarding system usability. Despite adoption of EHRs, many health professionals rate the usability of the systems as low. A range of usability issues have been noted when data is collected on a large scale through use of widely distributed questionnaires and websites designed to monitor user perceptions of usability. Conclusion As health information systems are deployed on a widespread basis, studies that examine systems used regionally or nationally are required. In addition, collection of large scale data on the usability of specific IT products is needed in order to complement smaller scale studies of specific systems. PMID:25123725

  16. Usability studies on e-learning platforms: Preliminary study in USM

    Science.gov (United States)

    Emang, Devinna Win Anak Boniface; Lukman, Raja Nurul Izzati Raja; Kamarulzaman, Muhammad Izzat Syafiq; Zaaba, Zarul Fitri

    2017-10-01

    This paper explores the end-users' experienced in regards to the usability issues in E-learning platform. An online survey utilising 116 participants were conducted to investigate the end-users understanding and satisfaction on E-learning platform in the Universiti Sains Malaysia (USM). The results indicates that mainly students still experiencing significant challenges in E-learning platform in regards to accessibility, technical terminologies and functionality. On the other hand, the 10 heuristic guideline is chosen to be a referral point to compare five E-learning platforms in order to assess each performance on regards to the usability criteria. Overall, USM E-learning platform can be considered in a good shape. However, there are more works to be done to improve the delivery system of the E-learning if it would like to sustain for a long period of time. Although the result is at the preliminary stage, it provides useful insights to improve the E-learning platform as one of the most popular education platform in Malaysia.

  17. Useful and usable alarm systems : recommended properties

    International Nuclear Information System (INIS)

    Veland, Oeystein; Kaarstad, Magnhild; Seim, Lars Aage; Foerdestroemmen, Nils T.

    2001-01-01

    This document describes the result of a study on alarm systems conducted by IFE in Halden. The study was initiated by the Norwegian Petroleum Directorate. The objective was to identify and formulate a set of important properties for useful and usable alarm systems. The study is mainly based on review of the latest international recognised guidelines and standards on alarm systems available at the time of writing, with focus on realistic solutions from research and best practice from different industries. In addition, IFE experiences gathered through specification and design of alarm systems and experimental activities in HAMMLAB and bilateral projects, have been utilized where relevant. The document presents a total of 43 recommendations divided into a number of general recommendations and more detailed recommendations on alarm generation, structuring, prioritisation, presentation and handling. (Author)

  18. Usability and feasibility of health IT interventions to enhance Self-Care for Lymphedema Symptom Management in breast cancer survivors

    Directory of Open Access Journals (Sweden)

    Mei R. Fu, PhD, RN, FAAN

    2016-09-01

    Conclusions: This usability study provided evidence on breast cancer survivor's acceptance and highly positive evaluation of TOLF's usability as well as feasibility of using technologically-driven delivery model to enhance self-care strategies for lymphedema symptom management.

  19. A review of privacy and usability issues in mobile health systems: Role of external factors.

    Science.gov (United States)

    Katusiime, Jane; Pinkwart, Niels

    2017-10-01

    The increased penetration of mobile devices has created opportunities in the health sector and led to emerging of mobile health systems. As much as the mobile health systems have registered tremendous progress, they have been faced with privacy and usability issues. Due to the sensitivity of health information, there is an ethical need to equip mobile health systems with adequate privacy measures. However, these systems should also be useable by the intended users. Even though many researchers are working on solutions, the issues still persist. External factors such as cultural differences have also contributed to the issues, yet they have been under researched. In this article, we conduct a systematic literature review of 22 articles, categorize and present privacy and usability issues and possible solutions. We then discuss the relevance and implications of external factors to the findings on privacy and usability. We end with recommendations to address these external factors.

  20. Software architecture analysis of usability

    NARCIS (Netherlands)

    Folmer, E; van Gurp, J; Bosch, J; Bastide, R; Palanque, P; Roth, J

    2005-01-01

    Studies of software engineering projects show that a large number of usability related change requests are made after its deployment. Fixing usability problems during the later stages of development often proves to be costly, since many of the necessary changes require changes to the system that

  1. Comparing two anesthesia information management system user interfaces: a usability evaluation.

    Science.gov (United States)

    Wanderer, Jonathan P; Rao, Anoop V; Rothwell, Sarah H; Ehrenfeld, Jesse M

    2012-11-01

    Anesthesia information management systems (AIMS) have been developed by multiple vendors and are deployed in thousands of operating rooms around the world, yet not much is known about measuring and improving AIMS usability. We developed a methodology for evaluating AIMS usability in a low-fidelity simulated clinical environment and used it to compare an existing user interface with a revised version. We hypothesized that the revised user interface would be more useable. In a low-fidelity simulated clinical environment, twenty anesthesia providers documented essential anesthetic information for the start of the case using both an existing and a revised user interface. Participants had not used the revised user interface previously and completed a brief training exercise prior to the study task. All participants completed a workload assessment and a satisfaction survey. All sessions were recorded. Multiple usability metrics were measured. The primary outcome was documentation accuracy. Secondary outcomes were perceived workload, number of documentation steps, number of user interactions, and documentation time. The interfaces were compared and design problems were identified by analyzing recorded sessions and survey results. Use of the revised user interface was shown to improve documentation accuracy from 85.1% to 92.4%, a difference of 7.3% (95% confidence interval [CI] for the difference 1.8 to 12.7). The revised user interface decreased the number of user interactions by 6.5 for intravenous documentation (95% CI 2.9 to 10.1) and by 16.1 for airway documentation (95% CI 11.1 to 21.1). The revised user interface required 3.8 fewer documentation steps (95% CI 2.3 to 5.4). Airway documentation time was reduced by 30.5 seconds with the revised workflow (95% CI 8.5 to 52.4). There were no significant time differences noted in intravenous documentation or in total task time. No difference in perceived workload was found between the user interfaces. Two user interface

  2. Tracing Impact in a Usability Improvement Process

    DEFF Research Database (Denmark)

    Uldall-Espersen, Tobias; Frøkjær, Erik; Hornbæk, Kasper Anders Søren

    2008-01-01

    Analyzing usability improvement processes as they take place in real-life organizations is necessary to understand the practice of usability work. This paper describes a case study where the usability of an information system is improved and a relationship between the improvements...... and the evaluation efforts is established. Results show that evaluation techniques complemented each other by suggesting different kinds of usability improvement. Among the techniques applied, a combination of questionnaires and Metaphors of Human Thinking (MOT) showed the largest mean impact and MOT produced...... the largest number of impacts. Logging of real-life use of the system over 6 months indicated six aspects of improved usability, where significant differences among evaluation techniques were found. Concerning five of the six aspects Think Aloud evaluations and the above-mentioned combination of questionnaire...

  3. How Do Clinical Information Systems Affect the Cognitive Demands of General Practitioners?: Usability Study with a Focus on Cognitive Workload

    Directory of Open Access Journals (Sweden)

    Ferran Ariza

    2015-11-01

    Full Text Available Background Clinical information systems in the National Health Service do not need to conform to any explicit usability requirements. Poor usability can increase the mental workload experienced by clinicians and cause fatigue, increase error rates and impact the overall patient safety. Mental workload can be used as a measure of usability.Objective To assess the subjective cognitive workload experienced by general practitioners (GPs with their systems. To raise awareness of the importance of usability in system design among users, designers, developers and policymakers.Methods We used a modified version of the NASA Task Load Index, adapted for web. We developed a set of common clinical scenarios and computer tasks on an online survey. We emailed the study link to 199 clinical commissioning groups and 1,646 GP practices in England. Results Sixty-seven responders completed the survey. The respondents had spent an average of 17 years in general practice, had experience of using a mean of 1.5 GP computer systems and had used their current system for a mean time of 6.7 years. The mental workload score was not different among systems. There were significant differences among the task scores, but these differences were not specific to particular systems. The overall score and task scores were related to the length of experience with their present system. Conclusion Four tasks imposed a higher mental workload on GPs: ‘repeat prescribing’, ‘find episode’, ‘drug management’ and ‘overview records’. Further usability studies on GP systems should focus on these tasks. Users, policymakers, designers and developers should remain aware of the importance of usability in system design.What does this study add?• Current GP systems in England do not need to conform to explicit usability requirements. Poor usability can increase the mental workload of clinicians and lead to errors.• Some clinical computer tasks incur more cognitive workload

  4. Software Development and Feedback from Usability Evaluations

    DEFF Research Database (Denmark)

    Høegh, Rune Thaarup

    2008-01-01

    This paper presents a study of the strengths and weaknesses of written, multimedia and oral feedback from usability evaluations to developers. The strengths and weaknesses are related to how well the feedback supports the developers in addressing usability problems in a software system. The study...... concludes that using the traditional written usability report, as the only form of feedback from usability evaluations is associated with problems related to the report not supporting the process of addressing the usability problems. The report is criticized for representing an overwhelming amount...... of information, while still not offering the required information to address usability problems. Other forms of feedback, such as oral or multimedia feedback helps the developer in understanding the usability problems better, but are on the other hand less cost-effective than a written description....

  5. Translation, Cross-Cultural Adaptation, and Validation of the Malay Version of the System Usability Scale Questionnaire for the Assessment of Mobile Apps.

    Science.gov (United States)

    Mohamad Marzuki, Muhamad Fadhil; Yaacob, Nor Azwany; Yaacob, Najib Majdi

    2018-05-14

    A mobile app is a programmed system designed to be used by a target user on a mobile device. The usability of such a system refers not only to the extent to which product can be used to achieve the task that it was designed for, but also its effectiveness and efficiency, as well as user satisfaction. The System Usability Scale is one of the most commonly used questionnaires used to assess the usability of a system. The original 10-item version of System Usability Scale was developed in English and thus needs to be adapted into local languages to assess the usability of a mobile apps developed in other languages. The aim of this study is to translate and validate (with cross-cultural adaptation) the English System Usability Scale questionnaire into Malay, the main language spoken in Malaysia. The development of a translated version will allow the usability of mobile apps to be assessed in Malay. Forward and backward translation of the questionnaire was conducted by groups of Malay native speakers who spoke English as their second language. The final version was obtained after reconciliation and cross-cultural adaptation. The content of the Malay System Usability Scale questionnaire for mobile apps was validated by 10 experts in mobile app development. The efficacy of the questionnaire was further probed by testing the face validity on 10 mobile phone users, followed by reliability testing involving 54 mobile phone users. The content validity index was determined to be 0.91, indicating good relevancy of the 10 items used to assess the usability of a mobile app. Calculation of the face validity index resulted in a value of 0.94, therefore indicating that the questionnaire was easily understood by the users. Reliability testing showed a Cronbach alpha value of .85 (95% CI 0.79-0.91) indicating that the translated System Usability Scale questionnaire is a reliable tool for the assessment of usability of a mobile app. The Malay System Usability Scale questionnaire is a

  6. Design and Usability Evaluation of Social Mobile Diabetes Management System in the Gulf Region.

    Science.gov (United States)

    Alanzi, Turki; Istepanian, Robert; Philip, Nada

    2016-09-26

    The prevalence of diabetes in the Gulf States is one of the highest globally. It is estimated that 20% of the population in the region has been diagnosed with diabetes and according to the International Diabetes Federation (IDF), five of the IDF's "top 10" countries for diabetes prevalence in 2011 and projected for 2030 are in this region. In recent years, there have been an increasing number of clinical studies advocating the use of mobile phone technology for diabetes self-management with improved clinical outcomes. However, there are few studies to date addressing the application of mobile diabetes management in the Gulf region, particularly in the Kingdom of Saudi Arabia (KSA), where there is exponential increase in mobile phone usage and access to social networking. The objective of this paper is to present the design and development of a new mobile health system for social behavioral change and management tailored for Saudi patients with diabetes called Saudi Arabia Networking for Aiding Diabetes (SANAD). A usability study for the SANAD system is presented to validate the acceptability of using mobile technologies among patients with diabetes in the KSA and the Gulf region. The SANAD system was developed using mobile phone technology with diabetes management and social networking modules. For the usability study the Questionnaire for User Interaction Satisfaction was used to evaluate the usability aspect of the SANAD system. A total of 33 users with type 2 diabetes participated in the study. The key modules of the SANAD system consist of (1) a mobile diabetes management module; (2) a social networking module; and (3) a cognitive behavioral therapy module for behavioral change issues. The preliminary results of the usability study indicated general acceptance of the patients in using the system with higher usability rating in patients with type 2 diabetes. We found that the acceptability of the system was high among Saudi patients with diabetes, and ongoing

  7. Usability/Sentiment for the Enterprise and ENTERPRISE

    Science.gov (United States)

    Meza, David; Berndt, Sarah

    2014-01-01

    The purpose of the Sentiment of Search Study for NASA Johnson Space Center (JSC) is to gain insight into the intranet search environment. With an initial usability survey, the authors were able to determine a usability score based on the Systems Usability Scale (SUS). Created in 1986, the freely available, well cited, SUS is commonly used to determine user perceptions of a system (in this case the intranet search environment). As with any improvement initiative, one must first examine and document the current reality of the situation. In this scenario, a method was needed to determine the usability of a search interface in addition to the user's perception on how well the search system was providing results. The use of the SUS provided a mechanism to quickly ascertain information in both areas, by adding one additional open-ended question at the end. The first ten questions allowed us to examine the usability of the system, while the last questions informed us on how the users rated the performance of the search results. The final analysis provides us with a better understanding of the current situation and areas to focus on for improvement. The power of search applications to enhance knowledge transfer is indisputable. The performance impact for any user unable to find needed information undermines project lifecycle, resource and scheduling requirements. Ever-increasing complexity of content and the user interface make usability considerations for the intranet, especially for search, a necessity instead of a 'nice-to-have'. Despite these arguments, intranet usability is largely disregarded due to lack of attention beyond the functionality of the infrastructure (White, 2013). The data collected from users of the JSC search system revealed their overall sentiment by means of the widely-known System Usability Scale. Results of the scores suggest 75%, +/-0.04, of the population rank the search system below average. In terms of a grading scaled, this equated to D or

  8. Palliative Care Planner: A Pilot Study to Evaluate Acceptability and Usability of an Electronic Health Records System-integrated, Needs-targeted App Platform.

    Science.gov (United States)

    Cox, Christopher E; Jones, Derek M; Reagan, Wen; Key, Mary D; Chow, Vinca; McFarlin, Jessica; Casarett, David; Creutzfeldt, Claire J; Docherty, Sharron L

    2018-01-01

    The quality and patient-centeredness of intensive care unit (ICU)-based palliative care delivery is highly variable. To develop and pilot an app platform for clinicians and ICU patients and their family members that enhances the delivery of needs-targeted palliative care. In the development phase of the study, we developed an electronic health record (EHR) system-integrated mobile web app system prototype, PCplanner (Palliative Care Planner). PCplanner screens the EHR for ICU patients meeting any of five prompts (triggers) for palliative care consultation, allows families to report their unmet palliative care needs, and alerts clinicians to these needs. The evaluation phase included a prospective before/after study conducted at a large academic medical center. Two control populations were enrolled in the before period to serve as context for the intervention. First, 25 ICU patients who received palliative care consults served as patient-level controls. Second, 49 family members of ICU patients who received mechanical ventilation for at least 48 hours served as family-level controls. Afterward, 14 patients, 18 family members, and 10 clinicians participated in the intervention evaluation period. Family member outcomes measured at baseline and 4 days later included acceptability (Client Satisfaction Questionnaire [CSQ]), usability (Systems Usability Scale [SUS]), and palliative care needs, assessed with the adapted needs of social nature, existential concerns, symptoms, and therapeutic interaction (NEST) scale; the Patient-Centeredness of Care Scale (PCCS); and the Perceived Stress Scale (PSS). Patient outcomes included frequency of goal concordant treatment, hospital length of stay, and discharge disposition. Family members reported high PCplanner acceptability (mean CSQ, 14.1 [SD, 1.4]) and usability (mean SUS, 21.1 [SD, 1.7]). PCplanner family member recipients experienced a 12.7-unit reduction in NEST score compared with a 3.4-unit increase among controls (P

  9. An investigation of the efficacy of collaborative virtual reality systems for moderated remote usability testing.

    Science.gov (United States)

    Chalil Madathil, Kapil; Greenstein, Joel S

    2017-11-01

    Collaborative virtual reality-based systems have integrated high fidelity voice-based communication, immersive audio and screen-sharing tools into virtual environments. Such three-dimensional collaborative virtual environments can mirror the collaboration among usability test participants and facilitators when they are physically collocated, potentially enabling moderated usability tests to be conducted effectively when the facilitator and participant are located in different places. We developed a virtual collaborative three-dimensional remote moderated usability testing laboratory and employed it in a controlled study to evaluate the effectiveness of moderated usability testing in a collaborative virtual reality-based environment with two other moderated usability testing methods: the traditional lab approach and Cisco WebEx, a web-based conferencing and screen sharing approach. Using a mixed methods experimental design, 36 test participants and 12 test facilitators were asked to complete representative tasks on a simulated online shopping website. The dependent variables included the time taken to complete the tasks; the usability defects identified and their severity; and the subjective ratings on the workload index, presence and satisfaction questionnaires. Remote moderated usability testing methodology using a collaborative virtual reality system performed similarly in terms of the total number of defects identified, the number of high severity defects identified and the time taken to complete the tasks with the other two methodologies. The overall workload experienced by the test participants and facilitators was the least with the traditional lab condition. No significant differences were identified for the workload experienced with the virtual reality and the WebEx conditions. However, test participants experienced greater involvement and a more immersive experience in the virtual environment than in the WebEx condition. The ratings for the virtual

  10. Developer Driven and User Driven Usability Evaluations

    DEFF Research Database (Denmark)

    Bruun, Anders

    2013-01-01

    Usability evaluation provide software development teams with insights on the degree to which a software application enables a user to achieve his/her goals, how fast these goals can be achieved, how easy it is to learn and how satisfactory it is in use Although usability evaluations are crucial...... in the process of developing software systems with a high level of usability, its use is still limited in the context of small software development companies. Several approaches have been proposed to support software development practitioners (SWPs) in conducting usability evaluations, and my thesis explores two...... of these: 1) The first approach is to support SWPs by training them to drive usability evaluations. 2) The second approach to support SWPs involves minimalist training of end users to drive usability evaluations. In related work, a set of five quality criteria for usability evaluations is applied...

  11. Usability evaluation of complex systems. A literature review

    International Nuclear Information System (INIS)

    Norros, L.; Savioja, P.

    2004-04-01

    In this literature study the task of usability evaluation is approached through recent publications and known practises. The scope of the reviewed literature and the overall problematic of evaluating complex systems are first defined. Then existing evaluation methods and tools and a set of design guidelines and standards is introduced. In there view the distinction between the evaluation of the design process and evaluation of the outcome of the design process is made. Also the existing criteria for usability is provided. These criteria can be used as measures in the evaluation procedures described in the previous chapter. Then, the problem of validity in the evaluation and validation procedures of complex cognitive systems is shortly discusses. The final chapter covers the conclusions of the literature review. There is a need for deepening the relationship between usage and design. Usage must be the driver also in the design of process technology, plant's safety, and instrumentation and control as well as that of the design of man-machine interface. The collaborative activity is called activity-oriented design. In order to enable activity-oriented design we need to create design methods that drive the design activity into this direction. Criteria for evaluating what is good design are not available in present standards. Criteria for good tools and practices must consider human in a favourable role in the various tasks of operating an industrial plant as opposed to the view of human as a source of error. This is the way to create an optimal system, which takes advantage of the unique capabilities of both the human operators and the automation systems. (orig.)

  12. Evaluating the Usability of Pinchigator, a system for Navigating Virtual Worlds using Pinch Gloves

    Science.gov (United States)

    Hamilton, George S.; Brookman, Stephen; Dumas, Joseph D. II; Tilghman, Neal

    2003-01-01

    Appropriate design of two dimensional user interfaces (2D U/I) utilizing the well known WIMP (Window, Icon, Menu, Pointing device) environment for computer software is well studied and guidance can be found in several standards. Three-dimensional U/I design is not nearly so mature as 2D U/I, and standards bodies have not reached consensus on what makes a usable interface. This is especially true when the tools for interacting with the virtual environment may include stereo viewing, real time trackers and pinch gloves instead of just a mouse & keyboard. Over the last several years the authors have created a 3D U/I system dubbed Pinchigator for navigating virtual worlds based on the dVise dV/Mockup visualization software, Fakespace Pinch Gloves and Pohlemus trackers. The current work is to test the usability of the system on several virtual worlds, suggest improvements to increase Pinchigator s usability, and then to generalize about what was learned and how those lessons might be applied to improve other 3D U/I systems.

  13. Usability of Public Administration Electronic Forms

    Directory of Open Access Journals (Sweden)

    Miloslav Hub

    2015-06-01

    Full Text Available This paper is focused on the testing and evaluating of public administration electronic forms from the usability point of view. Its objective is to design a suitable methodology for usability testing of electronic forms and their description and distribution to public administration information systems professionals. Firstly, methods of usability engineering are summarized and a suitable method for usability testing and evaluation of electronic forms is selected. Farther, the methodology of electronic forms usability testing that uses the selected method is suggested. In the last part of the paper the case study that uses the proposed methodology is suggested and performed. The main benefit of the work is the design of testing methodology and proposition of the set of recommendations for new public administration electronic forms design.

  14. Feedback from Usability Evaluation to User Interface Design

    DEFF Research Database (Denmark)

    Nielsen, C. M.; Overgaard, M.; Pedersen, M. B.

    2005-01-01

    This paper reports from an exploratory study of means for providing feedback from a usability evaluation to the user interface designers. In this study, we conducted a usability evaluation of a mobile system that is used by craftsmen to register use of time and materials. The results...... and weaknesses of the system. The findings indicate that detailed descriptions of problems and log descriptions of the user's interaction with the system and of system interaction are useful for the designers when trying to understand the usability problems that the users have encountered....

  15. A Framework for Usability Evaluation in EHR Procurement.

    Science.gov (United States)

    Tyllinen, Mari; Kaipio, Johanna; Lääveri, Tinja

    2018-01-01

    Usability should be considered already by the procuring organizations when selecting future systems. In this paper, we present a framework for usability evaluation during electronic health record (EHR) system procurement. We describe the objectives of the evaluation, the procedure, selected usability attributes and the evaluation methods to measure them. We also present the emphasis usability had in the selection process. We do not elaborate on the details of the results, the application of methods or gathering of data. Instead we focus on the components of the framework to inform and give an example to other similar procurement projects.

  16. Cost Effective Development of Usable Systems: Gaps between HCI and Software Architecture Design

    Science.gov (United States)

    Folmer, Eelke; Bosch, Jan

    A software product with poor usability is likely to fail in a highly competitive market; therefore software developing organizations are paying more and more attention to ensuring the usability of their software. Practice, however, shows that product quality (which includes usability among others) is not that high as it could be. Studies of software projects (Pressman, 2001) reveal that organizations spend a relative large amount of money and effort on fixing usability problems during late stage development. Some of these problems could have been detected and fixed much earlier. This avoidable rework leads to high costs and because during development different tradeoffs have to be made, for example between cost and quality leads to systems with less than optimal usability. This problem has been around for a couple of decades especially after software engineering (SE) and human computer interaction (HCI) became disciplines on their own. While both disciplines developed themselves, several gaps appeared which are now receiving increased attention in research literature. Major gaps of understanding, both between suggested practice and how software is actually developed in industry, but also between the best practices of each of the fields have been identified (Carrol et al, 1994, Bass et al, 2001, Folmer and Bosch, 2002). In addition, there are gaps in the fields of differing terminology, concepts, education, and methods.

  17. TRANSDERMAL DRUG DELIVERY SYSTEM: REVIEW

    OpenAIRE

    Vishvakarama Prabhakar; Agarwal Shivendra; Sharma Ritika; Saurabh Sharma

    2012-01-01

    Various new technologies have been developed for the transdermal delivery of some important drugs. Today about 74% of drugs are taken orally and are found not to be as effective as desired. To improve such characters transdermal drug delivery system was emerged. Drug delivery through the skin to achieve a systemic effect of a drug is commonly known as transdermal drug delivery and differs from traditional topical drug delivery. Transdermal drug delivery systems (TDDS) are dosage forms involve...

  18. UAV Delivery Monitoring System

    Directory of Open Access Journals (Sweden)

    San Khin Thida

    2018-01-01

    Full Text Available UAV-based delivery systems are increasingly being used in the logistics field, particularly to achieve faster last-mile delivery. This study develops a UAV delivery system that manages delivery order assignments, autonomous flight operation, real time control for UAV flights, and delivery status tracking. To manage the delivery item assignments, we apply the concurrent scheduler approach with a genetic algorithm. The present paper describes real time flight data based on a micro air vehicle communication protocol (MAVLink. It also presents the detailed hardware components used for the field tests. Finally, we provide UAV component analysis to choose the suitable components for delivery in terms of battery capacity, flight time, payload weight and motor thrust ratio.

  19. A usability test is not an interview

    DEFF Research Database (Denmark)

    Hertzum, Morten

    2016-01-01

    Usability tests are conducted to gauge users’ experience with a system, preferably before it is released for real use, and thereby find any problems that prevent users from completing their tasks, slow them down, or otherwise degrade their user experience. Such tests are important to successful...... systems development, yet test procedures vary and the quality of test results is sometimes contested. While there is no single accepted procedure for usability specialists to follow when conducting usability tests, these tests normally involve users who think out loud while using a system and an evaluator...... who observes the users’ behavior and listens in on their thoughts. This common core of usability tests is illustrated in Figure 1. The possible variations include, for example, whether the users work individually or in pairs, whether the evaluator is in the room with the user or in an adjoining room...

  20. Evaluating Usability

    DEFF Research Database (Denmark)

    Nørgaard, Mie; Høegh, Rune T.

    2008-01-01

    Usability evaluation is widely accepted as a valuable activity in software development. However, how results effectively are fed back to developers is still a relatively unexplored area. We argue that usability feedback can be understood as an argument for a series of usability problems......, and that basic concepts from argumentation theory can help us understand how to create persuasive feedback. We revisit two field studies on usability feedback to study if concepts from Toulmin's model for argumentation and Aristotle's modes of persuasion can explain why some feedback formats outperform others....... We recommend that evaluators specifically back up the warrants behind their usability claims, that their arguments use several modes of persuasion, and that they present feedback in browsable amounts not to overwhelm developers with information. For complex and controversial problems, we advise...

  1. Distributed user interfaces usability and collaboration

    CERN Document Server

    Lozano, María D; Tesoriero, Ricardo; Penichet, Victor MR

    2013-01-01

    Written by international researchers in the field of Distributed User Interfaces (DUIs), this book brings together important contributions regarding collaboration and usability in Distributed User Interface settings. Throughout the thirteen chapters authors address key questions concerning how collaboration can be improved by using DUIs, including: in which situations a DUI is suitable to ease the collaboration among users; how usability standards can be used to evaluate the usability of systems based on DUIs; and accurately describe case studies and prototypes implementing these concerns

  2. Usability and Accessibility of Air Force Intranet Web Sites

    National Research Council Canada - National Science Library

    Bentley, Richard S

    2006-01-01

    .... The Technology Acceptance Model suggests that information systems must not only be useful but also be usable and a large body of usability engineering knowledge exists to support usable design. In addition, the U.S...

  3. Development of a Just-in-Time Adaptive mHealth Intervention for Insomnia: Usability Study.

    Science.gov (United States)

    Pulantara, I Wayan; Parmanto, Bambang; Germain, Anne

    2018-05-17

    Healthy sleep is a fundamental component of physical and brain health. Insomnia, however, is a prevalent sleep disorder that compromises functioning, productivity, and health. Therefore, developing efficient treatment delivery methods for insomnia can have significant societal and personal health impacts. Cognitive behavioral therapy for insomnia (CBTI) is the recommended first-line treatment of insomnia but access is currently limited for patients, since treatment must occur in specialty sleep clinics, which suffer from an insufficient number of trained clinicians. Smartphone-based interventions offer a promising means for improving the delivery of CBTI. Furthermore, novel features such as real-time monitoring and assessment, personalization, dynamic adaptations of the intervention, and context awareness can enhance treatment personalization and effectiveness, and reduce associated costs. Ultimately, this "Just in Time Adaptive Intervention" for insomnia-an intervention approach that is acceptable to patients and clinicians, and is based on mobile health (mHealth) platform and tools-can significantly improve patient access and clinician delivery of evidence-based insomnia treatments. This study aims to develop and assess the usability of a Just in Time Adaptive Intervention application platform called iREST ("interactive Resilience Enhancing Sleep Tactics") for use in behavioral insomnia interventions. iREST can be used by both patients and clinicians. The development of iREST was based on the Iterative and Incremental Development software development model. Requirement analysis was based on the case study's description, workflow and needs, clinician inputs, and a previously conducted BBTI military study/implementation of the Just in Time Adaptive Intervention architecture. To evaluate the usability of the iREST mHealth tool, a pilot usability study was conducted. Additionally, this study explores the feasibility of using an off-the-shelf wearable device to

  4. Global usability

    CERN Document Server

    Douglas, Ian

    2011-01-01

    The concept of usability has become an increasingly important consideration in the design of all kinds of technology. As more products are aimed at global markets and developed through internationally distributed teams, usability design needs to be addressed in global terms. Interest in usability as a design issue and specialist area of research and education has developed steadily in North America and Europe since the 1980's. However, it is only over the last ten years that it has emerged as a global concern. Global Usability provides an introduction to the important issues in globalizing des

  5. PERBANDINGAN METODE EVALUASI USABILITY (STUDI KASUS : PENGGUNAAN PERANGKAT SMARTPHONE)

    OpenAIRE

    Hendradewa, Andrie Pasca

    2017-01-01

    Usability is a key factor that determine success of a product or interactive system, like smartphone. The increasing use of smartphone and its rapid technology development, requires usability evaluation method that is more accurate and effective to found usability problem, so it can be used for product improvement in development process. This study suggests a usability evaluation method that is most effective to identify problem in smartphone usage. Three usability evaluation methods that com...

  6. Peptide and protein delivery using new drug delivery systems.

    Science.gov (United States)

    Jain, Ashish; Jain, Aviral; Gulbake, Arvind; Shilpi, Satish; Hurkat, Pooja; Jain, Sanjay K

    2013-01-01

    Pharmaceutical and biotechnological research sorts protein drug delivery systems by importance based on their various therapeutic applications. The effective and potent action of the proteins/peptides makes them the drugs of choice for the treatment of numerous diseases. Major research issues in protein delivery include the stabilization of proteins in delivery devices and the design of appropriate target-specific protein carriers. Many efforts have been made for effective delivery of proteins/peptidal drugs through various routes of administrations for successful therapeutic effects. Nanoparticles made of biodegradable polymers such as poly lactic acid, polycaprolactone, poly(lactic-co-glycolic acid), the poly(fumaric-co-sebacic) anhydride chitosan, and modified chitosan, as well as solid lipids, have shown great potential in the delivery of proteins/peptidal drugs. Moreover, scientists also have used liposomes, PEGylated liposomes, niosomes, and aquasomes, among others, for peptidal drug delivery. They also have developed hydrogels and transdermal drug delivery systems for peptidal drug delivery. A receptor-mediated delivery system is another attractive strategy to overcome the limitation in drug absorption that enables the transcytosis of the protein across the epithelial barrier. Modification such as PEGnology is applied to various proteins and peptides of the desired protein and peptides also increases the circulating life, solubility and stability, pharmacokinetic properties, and antigenicity of protein. This review focuses on various approaches for effective protein/peptidal drug delivery, with special emphasis on insulin delivery.

  7. Usability and Applicability of Microfluidic Cell Culture Systems

    DEFF Research Database (Denmark)

    Hemmingsen, Mette

    possibilities for, for example, precise control of the chemical environment, 3D cultures, controlled co-culture of different cell types or automated, individual control of up to 96 cell culture chambers in one integrated system. Despite the great new opportunities to perform novel experimental designs......Microfluidic cell culture has been a research area with great attention the last decade due to its potential to mimic the in vivo cellular environment more closely compared to what is possible by conventional cell culture methods. Many exciting and complex devices have been presented providing......, these devices still lack general implementation into biological research laboratories. In this project, the usability and applicability of microfluidic cell culture systems have been investigated. The tested systems display good properties regarding optics and compatibility with standard laboratory equipment...

  8. Human Machine Interface and Usability Issues: Exploring a Preliminary Mission Management System Evaluation Methodology

    National Research Council Canada - National Science Library

    Kardos, Monique

    2001-01-01

    ...) concept demonstrator test during June 2000. The questionnaire was designed to examine usability and interface issues relating to the design of the systems or tools, and to provide suggestions for future iterations of the system...

  9. A Longitudinal Study of Usability in Health Care - Does Time Heal?

    DEFF Research Database (Denmark)

    Kjeldskov, Jesper; Skov, Mikael B.; Stage, Jan

    2007-01-01

    for 15 months, we repeated the evaluation. Our aim was to inquire into the nature of usability problems experienced by novice and expert users, and to see to what extend usability problems of a health care information system may or may not disappear over time, as the nurses get more familiar......We report from a longitudinal laboratory-based usability evaluation of a health care information system. A usability evaluation was conducted with novice users when an electronic patient record system was being deployed in a large hospital. After the nurses had used the system in their daily work...... with it – if time heals poor design. On the basis of our study, we present findings on the usability of the electronic patient system as experienced by the nurses at these two different points in time and discuss implications for evaluating usability in health care....

  10. Evaluation of Usability Utilizing Markov Models

    Science.gov (United States)

    Penedo, Janaina Rodrigues; Diniz, Morganna; Ferreira, Simone Bacellar Leal; Silveira, Denis S.; Capra, Eliane

    2012-01-01

    Purpose: The purpose of this paper is to analyze the usability of a remote learning system in its initial development phase, using a quantitative usability evaluation method through Markov models. Design/methodology/approach: The paper opted for an exploratory study. The data of interest of the research correspond to the possible accesses of users…

  11. Developing a Self-Report-Based Sequential Analysis Method for Educational Technology Systems: A Process-Based Usability Evaluation

    Science.gov (United States)

    Lin, Yi-Chun; Hsieh, Ya-Hui; Hou, Huei-Tse

    2015-01-01

    The development of a usability evaluation method for educational systems or applications, called the self-report-based sequential analysis, is described herein. The method aims to extend the current practice by proposing self-report-based sequential analysis as a new usability method, which integrates the advantages of self-report in survey…

  12. Usability evaluation of user interface of thesis title review system

    Science.gov (United States)

    Tri, Y.; Erna, A.; Gellysa, U.

    2018-03-01

    Presentation of programs with user interface that can be accessed online through the website of course greatly provide user benefits. User can easily access the program they need. There are usability values that serve as a benchmark for the success of a user accessible program, ie efficiency, effectiveness, and convenience. These usability values also determine the development of the program for the better use. Therefore, on the review title thesis program that will be implemented in STT Dumai was measured usability evaluation. It aims to see which sides are not yet perfect and need to be improved to improve the performance and utilization of the program. Usability evaluation was measured by using smartPLS software. Database used was the result of respondent questionnaires that include questions about the experience when they used program. The result of a review of thesis title program implemented in STT Dumai has an efficiency value of 22.615, the effectiveness of 20.612, and satisfaction of 33.177.

  13. UserTesting.com: A Tool for Usability Testing of Online Resources

    Science.gov (United States)

    Koundinya, Vikram; Klink, Jenna; Widhalm, Melissa

    2017-01-01

    Extension educators are increasingly using online resources in their program design and delivery. Usability testing is essential for ensuring that these resources are relevant and useful to learners. On the basis of our experiences with iteratively developing products using a testing service called UserTesting, we promote the use of fee-based…

  14. Safety and usability evaluation of a web-based insulin self-titration system for patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Simon, Airin C R; Holleman, Frits; Gude, Wouter T; Hoekstra, Joost B L; Peute, Linda W; Jaspers, Monique W M; Peek, Niels

    2013-09-01

    The rising incidence of type 2 diabetes mellitus (T2DM) induces severe challenges for the health care system. Our research group developed a web-based system named PANDIT that provides T2DM patients with insulin dosing advice using state of the art clinical decision support technology. The PANDIT interface resembles a glucose diary and provides advice through pop-up messages. Diabetes nurses (DNs) also have access to the system, allowing them to intervene when needed. The objective of this study was to establish whether T2DM patients can safely use PANDIT at home. To this end, we assessed whether patients experience usability problems with a high risk of compromising patient safety when interacting with the system, and whether PANDIT's insulin dosing advice are clinically safe. The study population consisted of patients with T2DM (aged 18-80) who used a once daily basal insulin as well as DNs from a university hospital. The usability evaluation consisted of think-aloud sessions with four patients and three DNs. Video data, audio data and verbal utterances were analyzed for usability problems encountered during PANDIT interactions. Usability problems were rated by a physician and a usability expert according to their potential impact on patient safety. The usability evaluation was followed by an implementation with a duration of four weeks. This implementation took place at the patients' homes with ten patients to evaluate clinical safety of PANDIT advice. PANDIT advice were systematically compared with DN advice. Deviating advice were evaluated with respect to patient safety by a panel of experienced physicians, which specialized in diabetes care. We detected seventeen unique usability problems, none of which was judged to have a high risk of compromising patient safety. Most usability problems concerned the lay-out of the diary, which did not clearly indicate which data entry fields had to be entered in order to obtain an advice. 27 out of 74 (36.5%) PANDIT advice

  15. Merits of usability testing for PACS selection

    NARCIS (Netherlands)

    Jorritsma, Wiard; Cnossen, Fokie; van Ooijen, Peter M. A.

    Objectives: To compare the usability of different Picture Archiving and Communication System (PACS) workstations, determine whether a usability test has added value with respect to the traditional way of comparing PACSs based on functional requirements, and to evaluate the appropriateness of a

  16. MATHEMATICAL MODEL FOR SOFTWARE USABILITY AUTOMATED EVALUATION AND ASSURANCE

    Directory of Open Access Journals (Sweden)

    І. Гученко

    2011-04-01

    Full Text Available The subject of the research is software usability and the aim is construction of mathematicalmodel of estimation and providing of the set level of usability. Methodology of structural analysis,methods of multicriterion optimization and theory of making decision, method of convolution,scientific methods of analysis and analogies is used in the research. The result of executed work isthe model for software usability automated evaluation and assurance that allows not only toestimate the current level of usability during every iteration of agile development but also tomanage the usability of created software products. Results can be used for the construction ofautomated support systems of management the software usability.

  17. Integrating Usability Evaluations into the Software Development Process

    DEFF Research Database (Denmark)

    Lizano, Fulvio

    as relevant and strategic human–computer interaction (HCI) activities in the software development process, there are obstacles that limit the complete, effective and efficient integration of this kind of testing into the software development process. Two main obstacles are the cost of usability evaluations...... and the software developers' resistance to accepting users’ opinions regarding the lack of usability in their software systems. The ‘cost obstacle’ refers to the constraint of conducting usability evaluations in the software process due to the significant amount of resources required by this type of testing. Some......This thesis addresses the integration of usability evaluations into the software development process. The integration here is contextualized in terms of how to include usability evaluation as an activity in the software development lifecycle. Even though usability evaluations are considered...

  18. Project delivery system (PDS)

    CERN Document Server

    2001-01-01

    As business environments become increasingly competitive, companies seek more comprehensive solutions to the delivery of their projects. "Project Delivery System: Fourth Edition" describes the process-driven project delivery systems which incorporates the best practices from Total Quality and is aligned with the Project Management Institute and ISO Quality Standards is the means by which projects are consistently and efficiently planned, executed and completed to the satisfaction of clients and customers.

  19. Synthetic sustained gene delivery systems.

    Science.gov (United States)

    Agarwal, Ankit; Mallapragada, Surya K

    2008-01-01

    Gene therapy today is hampered by the need of a safe and efficient gene delivery system that can provide a sustained therapeutic effect without cytotoxicity or unwanted immune responses. Bolus gene delivery in solution results in the loss of delivered factors via lymphatic system and may cause undesired effects by the escape of bioactive molecules to distant sites. Controlled gene delivery systems, acting as localized depot of genes, provide an extended sustained release of genes, giving prolonged maintenance of the therapeutic level of encoded proteins. They also limit the DNA degradation in the nuclease rich extra-cellular environment. While attempts have been made to adapt existing controlled drug delivery technologies, more novel approaches are being investigated for controlled gene delivery. DNA encapsulated in nano/micro spheres of polymers have been administered systemically/orally to be taken up by the targeted tissues and provide sustained release once internalized. Alternatively, DNA entrapped in hydrogels or scaffolds have been injected/implanted in tissues/cavities as platforms for gene delivery. The present review examines these different modalities for sustained delivery of viral and non-viral gene-delivery vectors. Design parameters and release mechanisms of different systems made with synthetic or natural polymers are presented along with their prospective applications and opportunities for continuous development.

  20. An In-home Advanced Robotic System to Manage Elderly Home-care Patients' Medications: A Pilot Safety and Usability Study.

    Science.gov (United States)

    Rantanen, Pekka; Parkkari, Timo; Leikola, Saija; Airaksinen, Marja; Lyles, Alan

    2017-05-01

    We examined the safety profile and usability of an integrated advanced robotic device and telecare system to promote medication adherence for elderly home-care patients. There were two phases. Phase I aimed to verify under controlled conditions in a single nursing home (n = 17 patients) that no robotic malfunctions would hinder the device's safe use. Phase II involved home-care patients from 3 sites (n = 27) who were on long-term medication. On-time dispensing and missed doses were recorded by the robotic system. Patients' and nurses' experiences were assessed with structured interviews. The 17 nursing home patients had 457 total days using the device (Phase I; mean, 26.9 per patient). On-time sachet retrieval occurred with 97.7% of the alerts, and no medication doses were missed. At baseline, Phase II home-dwelling patients reported difficulty remembering to take their medicines (23%), and 18% missed at least 2 doses per week. Most Phase II patients (78%) lived alone. The device delivered and patients retrieved medicine sachets for 99% of the alerts. All patients and 96% of nurses reported the device was easy to use. This trial demonstrated the safety profile and usability of an in-home advanced robotic device and telecare system and its acceptability to patients and nurses. It supports individualized patient dosing schedules, patient-provider communications, and on-time, in-home medication delivery to promote adherence. Real time dose-by-dose monitoring and communication with providers if a dose is missed provide oversight generally not seen in home care. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Colloidal drug delivery system: amplify the ocular delivery.

    Science.gov (United States)

    Ali, Javed; Fazil, Mohd; Qumbar, Mohd; Khan, Nazia; Ali, Asgar

    2016-01-01

    The ocular perceivers are the most voluntarily accessible organs in terms of location in the body, yet drug distribution to these tissues is one of the most intriguing and challenging endeavors and problematic to the pharmaceutical scientist. The most of ocular diseases are treated with topical application of conventional formulation, i.e. solutions, suspensions and ointment. Typically on installation of these conventional formulations, only <5% of the applied dose penetrates the cornea and reaches intraocular tissues, while a major fraction of the instilled dose is wastage due to the presence of many ocular barriers like external barriers, rapid loss of the instilled solution from the precorneal area and nasolacrimal drainage system. Systemic absorption caused systemic side effects varying from mild to life-threatening events. The main objective of this review is to explore the role of colloidal delivery of drug to minimize the drawbacks associated with them. This review provides an insight into the various constraints associated with ocular drug delivery, summarizes recent findings and applications of colloidal delivery systems, i.e. nanoparticles, nanosuspensions, liposomes, niosomes, dendrimers and contact lenses containing nanoparticles have the capacity to distribute ocular drugs to categorical target sites and hold promise to revolutionize the therapy of many ocular perceiver diseases and minimized the circumscription of conventional delivery. Form the basis of literature review, it has been found that the novel delivery system have greater impact to maximize ocular drug absorption, and minimize systemic absorption and side effects.

  2. Apathy towards the Integration of Usability Work

    DEFF Research Database (Denmark)

    Wale-Kolade, Adeola; Nielsen, Peter Axel

    2016-01-01

    In this article we report from a case study of a software development organization and we study in particular the developers’ and product managers’ attitudes towards integrating usability work into software development. We offer explanations based on system justification theory illuminating what...... would-be integrators might be up against. The analysis shows how the developers only pay lip service to usability work and how they treat users superficially. It further shows how that leads to stereotyping of usability designers and users in order to preserve status quo, and how internalization...... of inequality between the developers and usability designers rationalizes the preservation of status quo. These findings will have significant implications for managers of software development....

  3. Marketing through Usability.

    Science.gov (United States)

    Morgan, Eric Lease

    1999-01-01

    Suggests that one of the best ways to get word-of-mouth marketing of library technology is to provide "usable" products and services. Provides an international standards definition on usability and notes that understanding usability combines an understanding of user needs/wants with an understanding of goals, functions, and limitations…

  4. Comparative study of heuristic evaluation and usability testing methods.

    Science.gov (United States)

    Thyvalikakath, Thankam Paul; Monaco, Valerie; Thambuganipalle, Himabindu; Schleyer, Titus

    2009-01-01

    Usability methods, such as heuristic evaluation, cognitive walk-throughs and user testing, are increasingly used to evaluate and improve the design of clinical software applications. There is still some uncertainty, however, as to how those methods can be used to support the development process and evaluation in the most meaningful manner. In this study, we compared the results of a heuristic evaluation with those of formal user tests in order to determine which usability problems were detected by both methods. We conducted heuristic evaluation and usability testing on four major commercial dental computer-based patient records (CPRs), which together cover 80% of the market for chairside computer systems among general dentists. Both methods yielded strong evidence that the dental CPRs have significant usability problems. An average of 50% of empirically-determined usability problems were identified by the preceding heuristic evaluation. Some statements of heuristic violations were specific enough to precisely identify the actual usability problem that study participants encountered. Other violations were less specific, but still manifested themselves in usability problems and poor task outcomes. In this study, heuristic evaluation identified a significant portion of problems found during usability testing. While we make no assumptions about the generalizability of the results to other domains and software systems, heuristic evaluation may, under certain circumstances, be a useful tool to determine design problems early in the development cycle.

  5. Sample size in usability studies

    NARCIS (Netherlands)

    Schmettow, Martin

    2012-01-01

    Usability studies are important for developing usable, enjoyable products, identifying design flaws (usability problems) likely to compromise the user experience. Usability testing is recommended for improving interactive design, but discovery of usability problems depends on the number of users

  6. A Clinical Decision Support System for Chronic Pain Management in Primary Care: Usability testing and its relevance.

    Science.gov (United States)

    Nair, Kalpana Maria; Malaeekeh, Raheleh; Schabort, Inge; Taenzer, Paul; Radhakrishnan, Arun; Guenter, Dale

    2015-08-13

    Clinical decision support systems (CDSSs) that are integrated into electronic medical records may be useful for encouraging practice change compliant with clinical practice guidelines. To engage end users to inform early phase CDSS development through a process of usability testing. A sequential exploratory mixed method approach was used. Interprofessional clinician participants (seven in iteration 1 and six in iteration 2) were asked to 'think aloud' while performing various tasks on the CDSS and then complete the System Usability Scale (SUS). Changes were made to the CDSS after each iteration.Results Barriers and facilitators were identified: systemic; user interface (most numerous barriers); content (most numerous facilitators) and technical. The mean SUS score was 81.1 (SD = 12.02) in iteration 1 and 70.40 (SD = 6.78) in iteration 2 (p > 0.05). Qualitative data from usability testing were valuable in the CDSS development process. SUS scores were of limited value at this development stage.

  7. A Benchmark Usability Study of the Tactical Decision Making Under Stress Decision Support System

    National Research Council Canada - National Science Library

    Schmorrow, Dylan

    1998-01-01

    This study evaluates the usability of a U.S. Navy Decision Support System (DSS). The DSS was developed to enhance the performance of tactical decision makers within a Navy Combat Information Center...

  8. Self-nanoemulsifying drug delivery systems for oral insulin delivery

    DEFF Research Database (Denmark)

    Li, Ping; Tan, Angel; Prestidge, Clive A

    2014-01-01

    This study aims at evaluating the combination of self-nanoemulsifying drug delivery systems (SNEDDS) and enteric-coated capsules as a potential delivery strategy for oral delivery of insulin. The SNEDDS preconcentrates, loaded with insulin-phospholipid complex at different levels (0, 2.5 and 10% w...

  9. Usability testing of ANSWER: a web-based methotrexate decision aid for patients with rheumatoid arthritis.

    Science.gov (United States)

    Li, Linda C; Adam, Paul M; Townsend, Anne F; Lacaille, Diane; Yousefi, Charlene; Stacey, Dawn; Gromala, Diane; Shaw, Chris D; Tugwell, Peter; Backman, Catherine L

    2013-12-01

    Decision aids are evidence-based tools designed to inform people of the potential benefit and harm of treatment options, clarify their preferences and provide a shared decision-making structure for discussion at a clinic visit. For patients with rheumatoid arthritis (RA) who are considering methotrexate, we have developed a web-based patient decision aid called the ANSWER (Animated, Self-serve, Web-based Research Tool). This study aimed to: 1) assess the usability of the ANSWER prototype; 2) identify strengths and limitations of the ANSWER from the patient's perspective. The ANSWER prototype consisted of: 1) six animated patient stories and narrated information on the evidence of methotrexate for RA; 2) interactive questionnaires to clarify patients' treatment preferences. Eligible participants for the usability test were patients with RA who had been prescribed methotrexate. They were asked to verbalize their thoughts (i.e., think aloud) while using the ANSWER, and to complete the System Usability Scale (SUS) to assess overall usability (range = 0-100; higher = more user friendly). Participants were audiotaped and observed, and field notes were taken. The testing continued until no new modifiable issues were found. We used descriptive statistics to summarize participant characteristics and the SUS scores. Content analysis was used to identified usability issues and navigation problems. 15 patients participated in the usability testing. The majority were aged 50 or over and were university/college graduates (n = 8, 53.4%). On average they took 56 minutes (SD = 34.8) to complete the tool. The mean SUS score was 81.2 (SD = 13.5). Content analysis of audiotapes and field notes revealed four categories of modifiable usability issues: 1) information delivery (i.e., clarity of the information and presentation style); 2) navigation control (i.e., difficulties in recognizing and using the navigation control buttons); 3) layout (i.e., position of the

  10. Software Usability: Concepts, Attributes and Associated Health Problems

    Directory of Open Access Journals (Sweden)

    Grīnberga Sabīne

    2016-10-01

    Full Text Available Digital technologies have opened a large set of opportunities for new electronic services (e-commerce, e-health, e-studies etc.. There are many considerations that need to be made when programmers are building new application software or system software. The software needs to be attractive enough that people want to look at it. It also needs to contain all necessary information that developers want to share with their readers (customers, users in order to help them achieve the objective for which they came to their website, use their software, or interact with their teaching packages. The oversupply of e-services products has created a need for usability research and development. “Usability means making products and systems easier to use, and matching them more closely to user needs and requirements”. Usability is a key concept of the human-computer interface and is concerned with making computer systems easy to learn and easy to use through a user-centered design process. The in-depth understanding of usability concepts and processes are critical for large-scale acceptance of new e-services and knowledge productivity. Poorly designed software can be extremely annoying to users. Smith and Mayes state that „usability is now recognised as a vital determining factor in the success of any new computer system or computer-based service”. Studies have shown that the main health problems of computer users are repetitive strain injuries, visual discomfort and stress-related disorders. Beside other risk factors, such as poor workstation design, uncomfortable work postures, long hours of computer use every day, stress, etc., also poor design and usability of the computer systems, as well as computer technical problems, add to the pressure felt by the user, which may in turn cause stress-related disorders.

  11. Intra- and Inter-Cultural Usability in Computer-Supported Collaboration

    DEFF Research Database (Denmark)

    Vatrapu, Ravi; Suthers, Dan

    2010-01-01

    In this paper, we argue for an increased scope of universal design to encompass usability and accessibility for not only users with physical disabilities but also for users from different cultures. Towards this end, we present an empirical evaluation of cultural usability in computer......-Chinese, and Chinese-Chinese) appropriated affordances and produced technological intersubjectivity. Cultural usability was analyzed through the use of performance and satisfaction measures. The results show a systemic variation in efficiency, effectiveness, and satisfaction between the two cultural groups....... Implications of these findings for the research and practice of usability, in general, and cultural usability, in particular, are discussed in this paper....

  12. An object-oriented mobile health system with usability features.

    Science.gov (United States)

    Escarfullet, Krystle; Moore, Cantera; Tucker, Shari; Wei, June

    2012-01-01

    Mobile health (m-health) comprises the concept of utilising mobile devices to carry out the task of viewing electronic medical records, reserving medical appointments with a patient's medical provider and electronically refilling prescriptions. This paper aims at developing a m-health system to improve usability from a user's perspective. Specifically, it first developed a m-health model by logically linking characteristics of the m-health system together based on information flows. Then, the system requirements were collected by using a developed questionnaire. These requirements were structured and further in-depth analysis was conducted by using an object-oriented approach based on unified modelling language, such as use-case, sequence and analysis class diagrams. This research will be beneficial to decision makers and developers in the mobile healthcare industry.

  13. Cultural Usability

    DEFF Research Database (Denmark)

    Shi, Qingxin

    2007-01-01

    Culture has already played an important role in the global market. It not only affects products, but also impacts on usability evaluation methods. This project aims to examine in the established thinking aloud usability evaluation method (TA UEM), how does the evaluator build a supportive...

  14. A literature review about usability evaluation methods for e-learning platforms.

    Science.gov (United States)

    Freire, Luciana Lopes; Arezes, Pedro Miguel; Campos, José Creissac

    2012-01-01

    The usability analysis of information systems has been the target of several research studies over the past thirty years. These studies have highlighted a great diversity of points of view, including researchers from different scientific areas such as Ergonomics, Computer Science, Design and Education. Within the domain of information ergonomics, the study of tools and methods used for usability evaluation dedicated to E-learning presents evidence that there is a continuous and dynamic evolution of E-learning systems, in many different contexts -academics and corporative. These systems, also known as LMS (Learning Management Systems), can be classified according to their educational goals and their technological features. However, in these systems the usability issues are related with the relationship/interactions between user and system in the user's context. This review is a synthesis of research project about Information Ergonomics and embraces three dimensions, namely the methods, models and frameworks that have been applied to evaluate LMS. The study also includes the main usability criteria and heuristics used. The obtained results show a notorious change in the paradigms of usability, with which it will be possible to discuss about the studies carried out by different researchers that were focused on usability ergonomic principles aimed at E-learning.

  15. Usability Testing of Two Ambulatory EHR Navigators.

    Science.gov (United States)

    Hultman, Gretchen; Marquard, Jenna; Arsoniadis, Elliot; Mink, Pamela; Rizvi, Rubina; Ramer, Tim; Khairat, Saif; Fickau, Keri; Melton, Genevieve B

    2016-01-01

    Despite widespread electronic health record (EHR) adoption, poor EHR system usability continues to be a significant barrier to effective system use for end users. One key to addressing usability problems is to employ user testing and user-centered design. To understand if redesigning an EHR-based navigation tool with clinician input improved user performance and satisfaction. A usability evaluation was conducted to compare two versions of a redesigned ambulatory navigator. Participants completed tasks for five patient cases using the navigators, while employing a think-aloud protocol. The tasks were based on Meaningful Use (MU) requirements. The version of navigator did not affect perceived workload, and time to complete tasks was longer in the redesigned navigator. A relatively small portion of navigator content was used to complete the MU-related tasks, though navigation patterns were highly variable across participants for both navigators. Preferences for EHR navigation structures appeared to be individualized. This study demonstrates the importance of EHR usability assessments to evaluate group and individual performance of different interfaces and preferences for each design.

  16. Dogmas in the assessment of usability evaluation methods

    DEFF Research Database (Denmark)

    Hornbæk, Kasper

    2010-01-01

    Usability evaluation methods (UEMs) are widely recognised as an essential part of systems development. Assessments of the performance of UEMs, however, have been criticised for low validity and limited reliability. The present study extends this critique by describing seven dogmas in recent work ...... research approaches that may help move beyond the dogmas. In particular, we emphasise detailed studies of evaluation processes, assessments of the impact of UEMs on design carried out in real-world systems development and analyses of how UEMs may be combined......Usability evaluation methods (UEMs) are widely recognised as an essential part of systems development. Assessments of the performance of UEMs, however, have been criticised for low validity and limited reliability. The present study extends this critique by describing seven dogmas in recent work...... on UEMs. The dogmas include using inadequate procedures and measures for assessment, focusing on win-lose outcomes, holding simplistic models of how usability evaluators work, concentrating on evaluation rather than on design and working from the assumption that usability problems are real. We discuss...

  17. Exploring Multiple Usability Perspectives

    DEFF Research Database (Denmark)

    Uldall-Espersen, Tobias

    2007-01-01

    Industrial usability work often fails to produce the expected impact on software products even though significant resources have been used on uncovering problems and suggesting improvements. So, it seems that feedback from industrial usability work lacks persuasiveness, i.e. it fails to convince...... the key stakeholders that actions need to be taken. This study reports from interviews with 26 stakeholders in software development projects. Our data suggests that the interviewees address usability using different perspectives and based on our observations we describe five such perspectives. Further, we...... discuss how applying different usability perspectives might inform the persuasiveness of usability work....

  18. Usability Briefing for hospital design

    DEFF Research Database (Denmark)

    Fronczek-Munter, Aneta

    This PhD thesis is a contribution to an ongoing debate in Denmark about improving the building design processes of complex buildings, especially in relation to the current hospital developments. It provides knowledge about capturing user needs and defines the process model for usability briefing...... and evaluations, can be fed into briefing and design processes. This PhD thesis proposes methods for usability briefing.Usability is a concept similar to functionality, but usability depends on: subjective view of users, context, culture, situation and experience. Understanding usability is achieved by involving...... users. This PhD thesis extends the research in usability of buildings to include all building design phases, therefore not only proposes usability evaluations, but also defines usability briefing. Briefing, also called architectural programming, is usually understood as one of the first phases...

  19. Defining Usability of PN Services

    DEFF Research Database (Denmark)

    Nicolajsen, Hanne Westh; Ahola, Titta; Fleury, Alexandre

    In this deliverable usability and user experience are defined in relation to MAGNET Beyond technologies, and it is described how the main MAGNET Beyond concepts can be evaluated through the involvement of users. The concepts include the new "Activity based communication approach" for interacting...... with the MAGNET Beyond system, as well as the core concepts: Personal Network, Personal Network-Federation, Service Discovery, User Profile Management, Personal Network Management, Privacy and Security and Context Awareness. The overall plans for the final usability evaluation are documented based on the present...

  20. Multi-method laboratory user evaluation of an actionable clinical performance information system: Implications for usability and patient safety.

    Science.gov (United States)

    Brown, Benjamin; Balatsoukas, Panos; Williams, Richard; Sperrin, Matthew; Buchan, Iain

    2018-01-01

    Electronic audit and feedback (e-A&F) systems are used worldwide for care quality improvement. They measure health professionals' performance against clinical guidelines, and some systems suggest improvement actions. However, little is known about optimal interface designs for e-A&F, in particular how to present suggested actions for improvement. We developed a novel theory-informed system for primary care (the Performance Improvement plaN GeneratoR; PINGR) that covers the four principal interface components: clinical performance summaries; patient lists; detailed patient-level information; and suggested actions. As far as we are aware, this is the first report of an e-A&F system with all four interface components. (1) Use a combination of quantitative and qualitative methods to evaluate the usability of PINGR with target end-users; (2) refine existing design recommendations for e-A&F systems; (3) determine the implications of these recommendations for patient safety. We recruited seven primary care physicians to perform seven tasks with PINGR, during which we measured on-screen behaviour and eye movements. Participants subsequently completed usability questionnaires, and were interviewed in-depth. Data were integrated to: gain a more complete understanding of usability issues; enhance and explain each other's findings; and triangulate results to increase validity. Participants committed a median of 10 errors (range 8-21) when using PINGR's interface, and completed a median of five out of seven tasks (range 4-7). Errors violated six usability heuristics: clear response options; perceptual grouping and data relationships; representational formats; unambiguous description; visually distinct screens for confusable items; and workflow integration. Eye movement analysis revealed the integration of components largely supported effective user workflow, although the modular design of clinical performance summaries unnecessarily increased cognitive load. Interviews and

  1. Usability Metrics for Gamified E-learning Course: A Multilevel Approach

    Directory of Open Access Journals (Sweden)

    Aleksandra Sobodić

    2018-04-01

    Full Text Available This paper discusses the effect of a gamified learning system for students of the master course on Web Design and Programming performed at the Faculty of Organization and Informatics. A new set of usability metrics was derived from web-based learning usability, user experience and instructional design literature and incorporated into the questionnaire which consists of three main categories: Usability, Educational Usability and User Experience. The main contribution of this paper is the development and validation of a questionnaire for measuring the usability of a gamified e-learning course from students’ perspective. Usability practitioners can use the developed metrics with confidence when evaluating the design of a gamified e-learning course in order to improve students’ engagement and motivation.

  2. Usability: Human Research Program - Space Human Factors and Habitability

    Science.gov (United States)

    Sandor, Aniko; Holden, Kritina L.

    2009-01-01

    The Usability project addresses the need for research in the area of metrics and methodologies used in hardware and software usability testing in order to define quantifiable and verifiable usability requirements. A usability test is a human-in-the-loop evaluation where a participant works through a realistic set of representative tasks using the hardware/software under investigation. The purpose of this research is to define metrics and methodologies for measuring and verifying usability in the aerospace domain in accordance with FY09 focus on errors, consistency, and mobility/maneuverability. Usability metrics must be predictive of success with the interfaces, must be easy to obtain and/or calculate, and must meet the intent of current Human Systems Integration Requirements (HSIR). Methodologies must work within the constraints of the aerospace domain, be cost and time efficient, and be able to be applied without extensive specialized training.

  3. Preparing and evaluating delivery systems for proteins

    DEFF Research Database (Denmark)

    Jorgensen, L; Moeller, E H; van de Weert, M

    2006-01-01

    From a formulation perspective proteins are complex and therefore challenging molecules to develop drug delivery systems for. The success of a formulation depends on the ability of the protein to maintain the native structure and activity during preparation and delivery as well as during shipping...... and long-term storage of the formulation. Therefore, the development and evaluation of successful and promising drug delivery systems is essential. In the present review, some of the particulate drug delivery systems for parenteral delivery of protein are presented and discussed. The challenge...... for incorporation of protein in particulate delivery systems is exemplified by water-in-oil emulsions....

  4. Enhancing the Usability of an Optical Reader System to Support Point-of-Care Rapid Diagnostic Testing: An Iterative Design Approach.

    Science.gov (United States)

    Hohenstein, Jess; O'Dell, Dakota; Murnane, Elizabeth L; Lu, Zhengda; Erickson, David; Gay, Geri

    2017-11-21

    In today's health care environment, increasing costs and inadequate medical resources have created a worldwide need for more affordable diagnostic tools that are also portable, fast, and easy to use. To address this issue, numerous research and commercial efforts have focused on developing rapid diagnostic technologies; however, the efficacy of existing systems has been hindered by usability problems or high production costs, making them infeasible for deployment in at-home, point-of-care (POC), or resource-limited settings. The aim of this study was to create a low-cost optical reader system that integrates with any smart device and accepts any type of rapid diagnostic test strip to provide fast and accurate data collection, sample analysis, and diagnostic result reporting. An iterative design methodology was employed by a multidisciplinary research team to engineer three versions of a portable diagnostic testing device that were evaluated for usability and overall user receptivity. Repeated design critiques and usability studies identified a number of system requirements and considerations (eg, software compatibility, biomatter contamination, and physical footprint) that we worked to incrementally incorporate into successive system variants. Our final design phase culminated in the development of Tidbit, a reader that is compatible with any Wi-Fi-enabled device and test strip format. The Tidbit includes various features that support intuitive operation, including a straightforward test strip insertion point, external indicator lights, concealed electronic components, and an asymmetric shape, which inherently signals correct device orientation. Usability testing of the Tidbit indicates high usability for potential user communities. This study presents the design process, specification, and user reception of the Tidbit, an inexpensive, easy-to-use, portable optical reader for fast, accurate quantification of rapid diagnostic test results. Usability testing suggests

  5. Usability testing for dummies

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    Usability testing seems complicated and time-consuming. Is it though? In fact, it is the best way to understand how real users experience your product. In this interactive session, we will do a live usability test and you will get advice on how to conduct your own usability tests.

  6. Working together to improve usability

    DEFF Research Database (Denmark)

    Nørgaard, Mie; Hornbæk, Kasper

    2010-01-01

    In theory, usability work is an important and well-integrated activity in developing software. In practice, collaboration on improving usability is ridden with challenges relating to conflicting professional goals, tight project schedules, and unclear usability findings. The authors study those...... challenges through 16 interviews with software developers, usability experts, and project managers. Four themes that are key challenges to successful interaction between stakeholders are identified: poor timing when delivering usability results, results lacking relevance, little respect for other disciplines...

  7. A Systems Approach to Nitrogen Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Goins, Bobby [Y-12 National Security Complex, Oak Ridge, TN (United States)

    2017-10-23

    A systems based approach will be used to evaluate the nitrogen delivery process. This approach involves principles found in Lean, Reliability, Systems Thinking, and Requirements. This unique combination of principles and thought process yields a very in depth look into the system to which it is applied. By applying a systems based approach to the nitrogen delivery process there should be improvements in cycle time, efficiency, and a reduction in the required number of personnel needed to sustain the delivery process. This will in turn reduce the amount of demurrage charges that the site incurs. In addition there should be less frustration associated with the delivery process.

  8. A Systems Approach to Nitrogen Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Goins, Bobby [Y-12 National Security Complex, Oak Ridge, TN (United States); Univ. of Tennessee, Knoxville, TN (United States)

    2017-10-17

    A systems based approach will be used to evaluate the nitrogen delivery process. This approach involves principles found in Lean, Reliability, Systems Thinking, and Requirements. This unique combination of principles and thought process yields a very in depth look into the system to which it is applied. By applying a systems based approach to the nitrogen delivery process there should be improvements in cycle time, efficiency, and a reduction in the required number of personnel needed to sustain the delivery process. This will in turn reduce the amount of demurrage charges that the site incurs. In addition there should be less frustration associated with the delivery process.

  9. Usability Results from Human Performance Feedback and Development (HPFD) and ePerformance System Users: Technical Report #1

    National Research Council Canada - National Science Library

    Dean, Elizabeth; Aspinwall, Kimberly R; Schwerin, Michael J; Kendrick, Douglas E

    2006-01-01

    ...) and ePerformance system. This second and final iteration of usability testing was designed to verify the functionality of system revisions made as a result of recommendations offered in Schwerin et al. (2004...

  10. Usability Problem Identification in Culturally Diverse Settings

    DEFF Research Database (Denmark)

    Clemmensen, Torkil

    2012-01-01

    There are indications that established methods for evaluating information system usability that have been developed for use in, e.g. Europe or the USA, fail to give reliable results in countries such as India, China or Malaysia. This paper presents the theoretical background, related work...... and a definition of culture that should be useful for studies of multiple-country usability testing. This includes a discussion of cultural fit and the consequences of cultural (in)consistencies between stakeholders in system development and use. As an illustrative example of the kind of academic research...... that needs to be done, a pilot study is described. The pilot study exemplifies themes to explore, who should be participants and where should the study be done, how to find examples of multiple-country usability testing, how to collect data and how to analyse that data and what kind of results and discussion...

  11. A Facebook-Based Obesity Prevention Program for Korean American Adolescents: Usability Evaluation.

    Science.gov (United States)

    Park, Bu Kyung; Nahm, Eun-Shim; Rogers, Valerie E; Choi, Mona; Friedmann, Erika; Wilson, Marisa; Koru, Gunes

    Adolescent obesity is one of the most serious global public health challenges. Social networking sites are currently popular among adolescents. Therefore, the obesity prevention program for Korean American adolescents was developed on the most popular social networking site, Facebook. The purpose of this study was to evaluate the usability of a culturally tailored Facebook-based obesity prevention program for Korean American adolescents (Healthy Teens). An explorative descriptive design of usability testing was used. Usability testing employing one-on-one observation, the think-aloud method, audio taping, screen activity capture, and surveys was performed. Twenty participants were recruited from two Korean language schools (mean age, 15.40 ± 1.50 years). Recruitment and user testing was performed between February and April 2014. Content analysis, using the inductive coding approach, was performed by three coders to analyze transcriptions. Descriptive statistics were used to analyze quantitative data including demographic characteristics, perceived usability, eHealth literacy, and health behaviors. Testing revealed several usability issues in content, appearance, and navigation. Participants' comments regarding content were positive. Although the Facebook platform provided limited flexibility with respect to building the site, participants described the program's appearance as appropriate. Most participants did not experience difficulty in navigating the program. Our preliminary findings indicated that participants perceived the Healthy Teens program as usable and useful. This program could be used as a robust platform for the delivery of health education to adolescents. Further research is required to assess the effects of Facebook-based programs on adolescent obesity prevention. Copyright © 2016 National Association of Pediatric Nurse Practitioners. Published by Elsevier Inc. All rights reserved.

  12. STRATEGIES AND PROSPECTS OF NASAL DRUG DELIVERY SYSTEMS

    OpenAIRE

    Gannu Praveen Kumar

    2012-01-01

    The recent advancement of nasal drug delivery systems has increased enormously and is gaining significant importance. Intranasal therapy has been an accepted form of treatment in the Ayurvedic system of Indian Medicine. The non-invasive delivery of nasal drug delivery systems made to exploit for the development of successful treatment. The advantages, disadvantages, mechanism of action and application of nasal drug delivery system in local delivery, systematic delivery, nasal vaccines and CNS...

  13. Distributed usability evaluation

    DEFF Research Database (Denmark)

    Christensen, Lars; Frøkjær, Erik

    2010-01-01

    We present DUE (Distributed Usability Evaluation), a technique for collecting and evaluating usability data. The DUE infrastructure involves a client-server network. A client-based tool resides on the workstation of each user, providing a screen video recording, microphone input of voice commentary......, and a window for a severity rating. The idea is for the user to work naturalistically, clicking a button when a usability problem or point of uncertainty is encountered, to describe it verbally along with illustrating it on screen, and to rate its severity. These incidents are accumulated on a server......, providing access to an evaluator (usability expert) and to product developers or managers who want to review the incidents and analyse them. DUE supports evaluation in the development stages from running prototypes and onwards. A case study of the use of DUE in a corporate environment is presented...

  14. USABILITY TESTING OF JAPANESE CAPTIONS SEGMENTATION SYSTEM TO SCAFFOLD BEGINNERS TO COMPREHEND JAPANESE VIDEOS

    Directory of Open Access Journals (Sweden)

    Ya-Fei Yang

    2013-06-01

    Full Text Available A major learning difficulty of Japanese foreign language (JFL learners is the complex composition of two syllabaries, hiragana and katakana, and kanji characters adopted from logographic Chinese ones. As the number of Japanese language learners increases, computer-assisted Japanese language education gradually gains more attention. This study aimed to adopt a Japanese word segmentation system to help JFL learners overcome literacy problems. This study adopted MeCab, a Japanese morphological analyzer and part-of-speech (POS tagger, to segment Japanese texts into separate morphemes by adding spaces and to attach POS tags to each morpheme for beginners. The participants were asked to participate in three experimental activities involvingwatching two Japanese videos with general or segmented Japanese captions and complete the Nielsen’s Attributes of Usability (NAU survey and the After Scenario Questionnaire (ASQ to evaluate the usability of the learning activities. The results of the system evaluation showed that the videos with the segmented captions could increase the participants’ learning motivation and willingness to adopt the word segmentation system to learn Japanese.

  15. From Usability Engineering to Evidence-based Usability in Health IT

    NARCIS (Netherlands)

    Marcilly, Romaric; Peute, Linda; Beuscart-Zephir, Marie-Catherine

    2016-01-01

    Usability is a critical factor in the acceptance, safe use, and success of health IT. The User-Centred Design process is widely promoted to improve usability. However, this traditional case by case approach that is rooted in the sound understanding of users' needs is not sufficient to improve

  16. Fiber coupled optical spark delivery system

    Science.gov (United States)

    Yalin, Azer; Willson, Bryan; Defoort, Morgan

    2008-08-12

    A spark delivery system for generating a spark using a laser beam is provided, the spark delivery system including a laser light source and a laser delivery assembly. The laser delivery assembly includes a hollow fiber and a launch assembly comprising launch focusing optics to input the laser beam in the hollow fiber. In addition, the laser delivery assembly includes exit focusing optics that demagnify an exit beam of laser light from the hollow fiber, thereby increasing the intensity of the laser beam and creating a spark. In accordance with embodiments of the present invention, the assembly may be used to create a spark in a combustion engine. In accordance with other embodiments of the present invention, a method of using the spark delivery system is provided. In addition, a method of choosing an appropriate fiber for creating a spark using a laser beam is also presented.

  17. Usability testing of interaction components: taking the message exchange as a measure of usability

    NARCIS (Netherlands)

    Brinkman, W.P.; Haakma, R.; Bouwhuis, D.G.; Jacob, R.J.K.; Limbourg, Q; Vanderdonckt, J.

    2004-01-01

    Component-based Software Engineering (CBSE) is concerned with the development of systems from reusable parts (components), and the development and maintenance of these parts. This study addresses the issue of usability testing in a CBSE environment, and specifically automatically measuring the

  18. Cross cultural usability testing

    DEFF Research Database (Denmark)

    Clemmensen, Torkil; Goyal, Shivam

    2005-01-01

    In this paper, we present the results of a pilot study in Denmark of cross cultural effects on Think Aloud usability testing. We provide an overview of previous research on cross cultural usability evaluation with a special focus on the relationship between the evaluator and the test user....... This relation was studied in an experiment with usability testing of a localized clipart application in which eight participants from Denmark and India formed pairs of evaluator-test user. The test users were asked to think aloud and the evaluators' role were to facilitate the test users thinking aloud...... and hereby identify usability problems with the clipart application. Data on the evaluators' and test users' behaviour were recorded and analyzed by coding and summarizing statistics on these behavioural events. The results show that Think Aloud Usability Test of a localized application is most effectively...

  19. Enhancing usability using Near Field Communication for mobile application

    Directory of Open Access Journals (Sweden)

    Wihidayat Endar

    2018-01-01

    Full Text Available Near Field Communication (NFC as relatively new wireless communication technology pushes new challenges to application developers to make their applications easier to use and simpler to operate. This point of view known as usability element. Usability is one of the elements for creating good quality applications. This study aims to analyse the usability of mobile-based application embeds with NFC. We also try to evaluate usability in applications used by children. We developed an application called Receptionist which has a primary function as a communication tool between students, teachers and parents at a middle school. To know the impact of the NFC, the Receptionist input system is designed with two methods, via conventional navigation (using buttons and via NFC. To understand the usability of each method, we do user testing and questioners on students. The results show, using the NFC there is a significant increase in usability attributes: efficiency, effectiveness, and learnability. On the other hand, there is decreases of user satisfaction comparing to conventional method. In general, this study demonstrates the potential of new input device technologies that can improve the usability of mobile-based applications.

  20. Sterile Product Packaging and Delivery Systems.

    Science.gov (United States)

    Akers, Michael J

    2015-01-01

    Both conventional and more advanced product container and delivery systems are the focus of this brief article. Six different product container systems will be discussed, plus advances in primary packaging for special delivery systems and needle technology.

  1. Reduction of treatment delivery variances with a computer-controlled treatment delivery system

    International Nuclear Information System (INIS)

    Fraass, B.A.; Lash, K.L.; Matrone, G.M.; Lichter, A.S.

    1997-01-01

    Purpose: To analyze treatment delivery variances for 3-D conformal therapy performed at various levels of treatment delivery automation, ranging from manual field setup to virtually complete computer-controlled treatment delivery using a computer-controlled conformal radiotherapy system. Materials and Methods: All external beam treatments performed in our department during six months of 1996 were analyzed to study treatment delivery variances versus treatment complexity. Treatments for 505 patients (40,641 individual treatment ports) on four treatment machines were studied. All treatment variances noted by treatment therapists or quality assurance reviews (39 in all) were analyzed. Machines 'M1' (CLinac (6(100))) and 'M2' (CLinac 1800) were operated in a standard manual setup mode, with no record and verify system (R/V). Machines 'M3' (CLinac 2100CD/MLC) and ''M4'' (MM50 racetrack microtron system with MLC) treated patients under the control of a computer-controlled conformal radiotherapy system (CCRS) which 1) downloads the treatment delivery plan from the planning system, 2) performs some (or all) of the machine set-up and treatment delivery for each field, 3) monitors treatment delivery, 4) records all treatment parameters, and 5) notes exceptions to the electronically-prescribed plan. Complete external computer control is not available on M3, so it uses as many CCRS features as possible, while M4 operates completely under CCRS control and performs semi-automated and automated multi-segment intensity modulated treatments. Analysis of treatment complexity was based on numbers of fields, individual segments (ports), non-axial and non-coplanar plans, multi-segment intensity modulation, and pseudo-isocentric treatments (and other plans with computer-controlled table motions). Treatment delivery time was obtained from the computerized scheduling system (for manual treatments) or from CCRS system logs. Treatment therapists rotate among the machines, so this analysis

  2. Empirical usability testing in a component-based environment : improving test efficiency with component-specific usability measures

    NARCIS (Netherlands)

    Brinkman, W.P.; Haakma, R.; Bouwhuis, D.G.; Bastide, R.; Palanque, P.; Roth, J.

    2005-01-01

    This paper addresses the issue of usability testing in a component-based software engineering environment, specifically measuring the usability of different versions of a component in a more powerful manner than other, more holistic, usability methods. Three component-specific usability measures are

  3. Can eye tracking boost usability evaluation of computer games?

    DEFF Research Database (Denmark)

    Johansen, Sune Alstrup; Noergaard, Mie; Soerensen, Janus Rau

    2008-01-01

    Good computer games need to be challenging while at the same time being easy to use. Accordingly, besides struggling with well known challenges for usability work, such as persuasiveness, the computer game industry also faces system-specific challenges, such as identifying methods that can provide...... data on players' attention during a game. This position paper discusses how eye tracking may address three core challenges faced by computer game producer IO Interactive in their on-going work to ensure games that are fun, usable, and challenging. These challenges are: (1) Persuading game designers...... about the relevance of usability results, (2) involving game designers in usability work, and (3) identifying methods that provide new data about user behaviour and experience....

  4. MINI-SLAR delivery system

    International Nuclear Information System (INIS)

    Alstein, D.

    1996-01-01

    In the Spring of 1993, a need to complete Spacer Location and Repositioning (SLAR) on the Bruce 'A', Unit 1 Reactor was identified. An alternate SLAR delivery system was required due to conversion constraints that prevented the existing Bruce SLAR System from being used in Unit 1. A Portable SLAR Delivery System called MINI-SLAR Delivery System was developed, designed and fabricated in a 14 month period, then used to successfully SLAR 109 channels. The system is a portable remotely operated Nuclear Class 1 registered fitting that is independent of the Fuelling Machine, allowing the station to continue normal Fuelling and Maintenance activities. It is designed to a Level 'D' faulted condition of HPECI Pressure thus minimizing PHT Heat Sink configuration requirements and minimizing outage set-up times. The system is based on a modular design allowing for easy fabrication, assembly and repair. It consists of a Snout Assembly, a Closure Plug Assembly, Shield Plug Assembly, SLAR Ram assembly, Work Table Assembly and Control Panel. Controls are through a Programmable Logic Controller with software tested and certified to a Software Quality Assurance of Level Ill. (author). 2 refs., 2 figs

  5. MINI-SLAR delivery system

    Energy Technology Data Exchange (ETDEWEB)

    Alstein, D [Ontario Hydro, Tiverton, ON (Canada). Bruce Nuclear Generating Station-A; Dalton, K [Spectrum Engineering, Peterborough, ON (Canada)

    1997-12-31

    In the Spring of 1993, a need to complete Spacer Location and Repositioning (SLAR) on the Bruce `A`, Unit 1 Reactor was identified. An alternate SLAR delivery system was required due to conversion constraints that prevented the existing Bruce SLAR System from being used in Unit 1. A Portable SLAR Delivery System called MINI-SLAR Delivery System was developed, designed and fabricated in a 14 month period, then used to successfully SLAR 109 channels. The system is a portable remotely operated Nuclear Class 1 registered fitting that is independent of the Fuelling Machine, allowing the station to continue normal Fuelling and Maintenance activities. It is designed to a Level `D` faulted condition of HPECI Pressure thus minimizing PHT Heat Sink configuration requirements and minimizing outage set-up times. The system is based on a modular design allowing for easy fabrication, assembly and repair. It consists of a Snout Assembly, a Closure Plug Assembly, Shield Plug Assembly, SLAR Ram assembly, Work Table Assembly and Control Panel. Controls are through a Programmable Logic Controller with software tested and certified to a Software Quality Assurance of Level Ill. (author). 2 refs., 2 figs.

  6. Health care delivery systems.

    NARCIS (Netherlands)

    Stevens, F.; Zee, J. van der

    2007-01-01

    A health care delivery system is the organized response of a society to the health problems of its inhabitants. Societies choose from alternative health care delivery models and, in doing so, they organize and set goals and priorities in such a way that the actions of different actors are effective,

  7. Designing and assessing a sustainable networked delivery (SND) system: hybrid business-to-consumer book delivery case study.

    Science.gov (United States)

    Kim, Junbeum; Xu, Ming; Kahhat, Ramzy; Allenby, Braden; Williams, Eric

    2009-01-01

    We attempted to design and assess an example of a sustainable networked delivery (SND) system: a hybrid business-to-consumer book delivery system. This system is intended to reduce costs, achieve significant reductions in energy consumption, and reduce environmental emissions of critical local pollutants and greenhouse gases. The energy consumption and concomitant emissions of this delivery system compared with existing alternative delivery systems were estimated. We found that regarding energy consumption, an emerging hybrid delivery system which is a sustainable networked delivery system (SND) would consume 47 and 7 times less than the traditional networked delivery system (TND) and e-commerce networked delivery system (END). Regarding concomitant emissions, in the case of CO2, the SND system produced 32 and 7 times fewer emissions than the TND and END systems. Also the SND system offer meaningful economic benefit such as the costs of delivery and packaging, to the online retailer, grocery, and consumer. Our research results show that the SND system has a lot of possibilities to save local transportation energy consumption and delivery costs, and reduce environmental emissions in delivery system.

  8. Towards Usable E-Health. A Systematic Review of Usability Questionnaires.

    Science.gov (United States)

    Sousa, Vanessa E C; Dunn Lopez, Karen

    2017-05-10

    The use of e-health can lead to several positive outcomes. However, the potential for e-health to improve healthcare is partially dependent on its ease of use. In order to determine the usability for any technology, rigorously developed and appropriate measures must be chosen. To identify psychometrically tested questionnaires that measure usability of e-health tools, and to appraise their generalizability, attributes coverage, and quality. We conducted a systematic review of studies that measured usability of e-health tools using four databases (Scopus, PubMed, CINAHL, and HAPI). Non-primary research, studies that did not report measures, studies with children or people with cognitive limitations, and studies about assistive devices or medical equipment were systematically excluded. Two authors independently extracted information including: questionnaire name, number of questions, scoring method, item generation, and psychometrics using a data extraction tool with pre-established categories and a quality appraisal scoring table. Using a broad search strategy, 5,558 potentially relevant papers were identified. After removing duplicates and applying exclusion criteria, 35 articles remained that used 15 unique questionnaires. From the 15 questionnaires, only 5 were general enough to be used across studies. Usability attributes covered by the questionnaires were: learnability (15), efficiency (12), and satisfaction (11). Memorability (1) was the least covered attribute. Quality appraisal showed that face/content (14) and construct (7) validity were the most frequent types of validity assessed. All questionnaires reported reliability measurement. Some questionnaires scored low in the quality appraisal for the following reasons: limited validity testing (7), small sample size (3), no reporting of user centeredness (9) or feasibility estimates of time, effort, and expense (7). Existing questionnaires provide a foundation for research on e-health usability. However

  9. What makes a control system usable? An operational viewpoint

    International Nuclear Information System (INIS)

    Clay, M.

    1990-01-01

    This report discusses the generally accepted successes and shortcomings of the various computer and hardware-based control systems at the Los Alamos Meson Physics Facility (LAMPF) from an operator's standpoint. LAMPF currently utilizes three separate control rooms that, although critically co-dependent, use distinct operating methods. The first, the Injector Control Room, which is responsible for the operation of the three ion sources, the 750 keV transport lines and the 201.25 MHz portion of the linac, uses a predominantly hardware-based control system. The second, the LANSCE Control Room, which is responsible for the operation of the Los Alamos Neutron Scattering Center, uses a graphical touch-panel interface with single-application screens as its control system. The third, the LAMPF Central Control Room, which is responsible for the overall operation of LAMPF, primarily uses a text-oriented keyboard interface with multiple applications per screen. Though each system provides generally reliable human interfacing to the enormously complex and diverse machine known as LAMPF, the operational requirements of speed, usability, and reliability are increasingly necessitating the use of a standard control system that incorporates the positive aspects of all three control systems. (orig.)

  10. Users' performance in lab and non-lab environments through online usability testing:A case of evaluating the usability of digital academic libraries' websites

    OpenAIRE

    Alharbi, Abeer; Mayhew, Pam

    2015-01-01

    The factors related to the environment in which users operate may be of a vital importance when trying to understand how they experience a particular system. It is required that we find out how we can get to know those factors to investigate if they affect the users' performance in usability testing. An online usability study has emerged that can be attempted by a large, varied pool of users' anywhere with an Internet connection. Would the usage of an online usability study help to give compr...

  11. Usability at the CELSTEC Medialab

    NARCIS (Netherlands)

    Storm, Jeroen; Kostons, Danny

    2009-01-01

    Storm, J., & Kostons, D. (2009). Usability at the CELSTEC MediaLab. Presentation about the usability testing, usability research and User Centered Design conducted at the CELSTEC MediaLab. July, 7, 2009, Heerlen, The Netherlands: Open University of the Netherlands.

  12. Some Recent Advances in Transdermal Drug Delivery Systems ...

    African Journals Online (AJOL)

    Some Recent Advances in Transdermal Drug Delivery Systems. ... Advances in Transdermal Drug Delivery Systems. EC Ibezim, B Kabele-Toge, CO Anie, C Njoku. Abstract. Transdermal delivery systems are forms of drug delivery involving the dermis, as distinct from topical, oral or other forms of parenteral dosage forms.

  13. Usability testing of the human-machine interface for the Light Duty Utility Arm System

    International Nuclear Information System (INIS)

    Kiebel, G.R.; Ellis, J.E.; Masliah, M.R.

    1994-01-01

    This report describes the usability testing that has been done for the control and data acquisition system for the Light Duty Utility Arm (LDUA) System. A program of usability testing has been established as a part of a process for making the LDUA as easy to use as possible. The LDUA System is being designed to deploy a family of tools, called End Effectors, into underground storage tanks by means of a robotic arm on the end of a telescoping mast, and to collect and manage the data that they generate. The LDUA System uses a vertical positioning mast, to lower the arm into a tank through an existing 30.5 cm access riser. A Mobile Deployment Subsystem is used to position the mast and arm over a tank riser for deployment, and to transport them from tank to tank. The LDUA System has many ancillary subsystems including the Operations Control Trailer, the Tank Riser Interface and Confinement Subsystem, the Decontamination Subsystem, and the End Effector Exchange Subsystem. This work resulted in the identification of several important improvements to the LDUA control and data acquisition system before the design was frozen. The most important of these were color coding of joints in motion, simultaneous operator control of multiple joints, and changes to the field-of-views of the camera lenses for the robot and other camera systems

  14. Drug delivery systems with modified release for systemic and biophase bioavailability.

    Science.gov (United States)

    Leucuta, Sorin E

    2012-11-01

    This review describes the most important new generations of pharmaceutical systems: medicines with extended release, controlled release pharmaceutical systems, pharmaceutical systems for the targeted delivery of drug substances. The latest advances and approaches for delivering small molecular weight drugs and other biologically active agents such as proteins and nucleic acids require novel delivery technologies, the success of a drug being many times dependent on the delivery method. All these dosage forms are qualitatively superior to medicines with immediate release, in that they ensure optimal drug concentrations depending on specific demands of different disease particularities of the body. Drug delivery of these pharmaceutical formulations has the benefit of improving product efficacy and safety, as well as patient convenience and compliance. This paper describes the biopharmaceutical, pharmacokinetic, pharmacologic and technological principles in the design of drug delivery systems with modified release as well as the formulation criteria of prolonged and controlled release drug delivery systems. The paper presents pharmaceutical prolonged and controlled release dosage forms intended for different routes of administration: oral, ocular, transdermal, parenteral, pulmonary, mucoadhesive, but also orally fast dissolving tablets, gastroretentive drug delivery systems, colon-specific drug delivery systems, pulsatile drug delivery systems and carrier or ligand mediated transport for site specific or receptor drug targeting. Specific technologies are given on the dosage forms with modified release as well as examples of marketed products, and current research in these areas.

  15. Usability testing a practical guide for librarians

    CERN Document Server

    Blakiston, Rebecca

    2014-01-01

    Do you want to improve the usability of your library website, but feel that it is too difficult, time-consuming, or expensive? Usability Testing: A Practical Guide for Librarians will teach you how to make the case for usability testing, define your audience and their goals, select a usability testing method appropriate for your particular context, plan for an in-house usability test, conduct an effective in-house usability test, analyze usability test results, and create and implement a plan for ongoing, systematic usability testing. Step-by-step instructions, along with a myriad of examples,

  16. Future of Automated Insulin Delivery Systems.

    Science.gov (United States)

    Castle, Jessica R; DeVries, J Hans; Kovatchev, Boris

    2017-06-01

    Advances in continuous glucose monitoring (CGM) have brought on a paradigm shift in the management of type 1 diabetes. These advances have enabled the automation of insulin delivery, where an algorithm determines the insulin delivery rate in response to the CGM values. There are multiple automated insulin delivery (AID) systems in development. A system that automates basal insulin delivery has already received Food and Drug Administration approval, and more systems are likely to follow. As the field of AID matures, future systems may incorporate additional hormones and/or multiple inputs, such as activity level. All AID systems are impacted by CGM accuracy and future CGM devices must be shown to be sufficiently accurate to be safely incorporated into AID. In this article, we summarize recent achievements in AID development, with a special emphasis on CGM sensor performance, and discuss the future of AID systems from the point of view of their input-output characteristics, form factor, and adaptability.

  17. Software architecture analysis of usability

    NARCIS (Netherlands)

    Folmer, Eelke

    2005-01-01

    One of the qualities that has received increased attention in recent decades is usability. A software product with poor usability is likely to fail in a highly competitive market; therefore software developing organizations are paying more and more attention to ensuring the usability of their

  18. Dynamic Tunnel Usability Study: Format Recommendations for Synthetic Vision System Primary Flight Displays

    Science.gov (United States)

    Arthur, Jarvis J., III; Prinzel, Lawrence J., III; Kramer, Lynda J.; Bailey, Randall E.

    2006-01-01

    A usability study evaluating dynamic tunnel concepts has been completed under the Aviation Safety and Security Program, Synthetic Vision Systems Project. The usability study was conducted in the Visual Imaging Simulator for Transport Aircraft Systems (VISTAS) III simulator in the form of questionnaires and pilot-in-the-loop simulation sessions. Twelve commercial pilots participated in the study to determine their preferences via paired comparisons and subjective rankings regarding the color, line thickness and sensitivity of the dynamic tunnel. The results of the study showed that color was not significant in pilot preference paired comparisons or in pilot rankings. Line thickness was significant for both pilot preference paired comparisons and in pilot rankings. The preferred line/halo thickness combination was a line width of 3 pixels and a halo of 4 pixels. Finally, pilots were asked their preference for the current dynamic tunnel compared to a less sensitive dynamic tunnel. The current dynamic tunnel constantly gives feedback to the pilot with regard to path error while the less sensitive tunnel only changes as the path error approaches the edges of the tunnel. The tunnel sensitivity comparison results were not statistically significant.

  19. Evaluating Web Usability

    Science.gov (United States)

    Snider, Jean; Martin, Florence

    2012-01-01

    Web usability focuses on design elements and processes that make web pages easy to use. A website for college students was evaluated for underutilization. One-on-one testing, focus groups, web analytics, peer university review and marketing focus group and demographic data were utilized to conduct usability evaluation. The results indicated that…

  20. A Fuzzy method for the usability evaluation of nuclear medical equipment

    Energy Technology Data Exchange (ETDEWEB)

    Grecco, Cláudio H.S.; Santos, Isaac J.A.L.; Farias, Marcos S.; Farias, Larissa P.; Filho, Alfredo M.V., E-mail: grecco@ien.gov.br, E-mail: luquetti@ien.gov.br, E-mail: msantana@ien.gov.br, E-mail: larissapfarias@ymail.com, E-mail: marques@ien.gov.br [Instituto de Engenharia Nuclear (DENN/IEN/CNEN/RJ), Rio de Janeiro, RJ (Brazil). Departamento de Engenharia Nuclear

    2017-11-01

    To avoid errors when handling nuclear medical equipment, it is important to develop products with a high degree of usability. This can be achieved by performing usability evaluations in the product development process to detect and mitigate potential usability problems. Usability evaluation focuses on how well users can learn and use a product to achieve their goals. Thus, the usability evaluation has become recognized as a valuable complement to the established approaches to design good user interfaces, to reduce incidents and accidents as well the time required to learn how to use the equipment. To gather information about usability, practitioners use a variety of methods that gather feedback from users about an existing interface or plans related to a new interface. A wide range of usability evaluation methods have been proposed, but few methods focus on developing an objective and practical evaluation method for usability. Moreover, the usability evaluations are based on human judgments and most methods cannot fully solve the subjectivity of these evaluations. In order to remedy this deficiency, the purpose of this work is to adopt a Fuzzy Set Theory (FST) approach to establish a method for the usability evaluation of nuclear medical equipment based on usability heuristics for user interface design and international standards for ergonomics of human-system interaction. To exemplify the method we performed a usability evaluating of the Digital Spectrometer ESP 13004 by testing it with representative users. The results showed that the method is a proactive tool to provide a basis for checking usability of medical device interfaces. (author)

  1. A Fuzzy method for the usability evaluation of nuclear medical equipment

    International Nuclear Information System (INIS)

    Grecco, Cláudio H.S.; Santos, Isaac J.A.L.; Farias, Marcos S.; Farias, Larissa P.; Filho, Alfredo M.V.

    2017-01-01

    To avoid errors when handling nuclear medical equipment, it is important to develop products with a high degree of usability. This can be achieved by performing usability evaluations in the product development process to detect and mitigate potential usability problems. Usability evaluation focuses on how well users can learn and use a product to achieve their goals. Thus, the usability evaluation has become recognized as a valuable complement to the established approaches to design good user interfaces, to reduce incidents and accidents as well the time required to learn how to use the equipment. To gather information about usability, practitioners use a variety of methods that gather feedback from users about an existing interface or plans related to a new interface. A wide range of usability evaluation methods have been proposed, but few methods focus on developing an objective and practical evaluation method for usability. Moreover, the usability evaluations are based on human judgments and most methods cannot fully solve the subjectivity of these evaluations. In order to remedy this deficiency, the purpose of this work is to adopt a Fuzzy Set Theory (FST) approach to establish a method for the usability evaluation of nuclear medical equipment based on usability heuristics for user interface design and international standards for ergonomics of human-system interaction. To exemplify the method we performed a usability evaluating of the Digital Spectrometer ESP 13004 by testing it with representative users. The results showed that the method is a proactive tool to provide a basis for checking usability of medical device interfaces. (author)

  2. Evaluating the Usability of Authoring Environments for Serious Games.

    Science.gov (United States)

    Slootmaker, Aad; Hummel, Hans; Koper, Rob

    2017-08-01

    Background . The EMERGO method and online platform enable the development and delivery of scenario-based serious games that foster students to acquire professional competence. One of the main goals of the platform is to provide a user-friendly authoring environment for creating virtual environments where students can perform authentic tasks. Aim . We present the findings of an in-depth qualitative case study of the platform's authoring environment and compare our findings on usability with those found for comparable environments in literature. Method . We carried out semi-structured interviews, with two experienced game developers who have authored a game for higher education, and a literature review of comparable environments. Findings . The analysis shows that the usability of the authoring environment is problematic, especially regarding understandability and learnability , which is in line with findings of comparable environments. Other findings are that authoring is well integrated with the EMERGO method and that functionality and reliability of the authoring environment are valued. Practical implications . The lessons learned are presented in the form of general guidelines to improve the understandability and learnability of authoring environments for serious games .

  3. Communications data delivery system analysis task 2 report : high-level options for secure communications data delivery systems.

    Science.gov (United States)

    2012-05-16

    This Communications Data Delivery System Analysis Task 2 report describes and analyzes options for Vehicle to Vehicle (V2V) and Vehicle to Infrastructure (V2I) communications data delivery systems using various communication media (Dedicated Short Ra...

  4. Usability Testing for Developing Effective Interactive Multimedia Software: Concepts, Dimensions, and Procedures

    Directory of Open Access Journals (Sweden)

    Sung Heum Lee

    1999-04-01

    Full Text Available Usability testing is a dynamic process that can be used throughout the process of developing interactive multimedia software. The purpose of usability testing is to find problems and make recommendations to improve the utility of a product during its design and development. For developing effective interactive multimedia software, dimensions of usability testing were classified into the general categories of: learnability; performance effectiveness; flexibility; error tolerance and system integrity; and user satisfaction. In the process of usability testing, evaluation experts consider the nature of users and tasks, tradeoffs supported by the iterative design paradigm, and real world constraints to effectively evaluate and improve interactive multimedia software. Different methods address different purposes and involve a combination of user and usability testing, however, usability practitioners follow the seven general procedures of usability testing for effective multimedia development. As the knowledge about usability testing grows, evaluation experts will be able to choose more effective and efficient methods and techniques that are appropriate to their goals.

  5. Levodopa delivery systems: advancements in delivery of the gold standard.

    Science.gov (United States)

    Ngwuluka, Ndidi; Pillay, Viness; Du Toit, Lisa C; Ndesendo, Valence; Choonara, Yahya; Modi, Girish; Naidoo, Dinesh

    2010-02-01

    Despite the fact that Parkinson's disease (PD) was discovered almost 200 years ago, its treatment and management remain immense challenges because progressive loss of dopaminergic nigral neurons, motor complications experienced by the patients as the disease progresses and drawbacks of pharmacotherapeutic management still persist. Various therapeutic agents have been used in the management of PD, including levodopa (l-DOPA), selegiline, amantadine, bromocriptine, entacapone, pramipexole dihydrochloride and more recently istradefylline and rasagiline. Of all agents, l-DOPA although the oldest, remains the most effective. l-DOPA is easier to administer, better tolerated, less expensive and is required by almost all PD patients. However, l-DOPA's efficacy in advanced PD is significantly reduced due to metabolism, subsequent low bioavailability and irregular fluctuations in its plasma levels. Significant strides have been made to improve the delivery of l-DOPA in order to enhance its bioavailability and reduce plasma fluctuations as well as motor complications experienced by patients purportedly resulting from pulsatile stimulation of the striatal dopamine receptors. Drug delivery systems that have been instituted for the delivery of l-DOPA include immediate release formulations, liquid formulations, dispersible tablets, controlled release formulations, dual-release formulations, microspheres, infusion and transdermal delivery, among others. In this review, the l-DOPA-loaded drug delivery systems developed over the past three decades are elaborated. The ultimate aim was to assess critically the attempts made thus far directed at improving l-DOPA absorption, bioavailability and maintenance of constant plasma concentrations, including the drug delivery technologies implicated. This review highlights the fact that neuropharmaceutics is at a precipice, which is expected to spur investigators to take that leap to enable the generation of innovative delivery systems for the

  6. Usability Study Identifies Vocabulary, Facets, and Education as Primary Primo Discovery System Interface Problems

    Directory of Open Access Journals (Sweden)

    Ruby Muriel Lavallee Warren

    2017-09-01

    Full Text Available A Review of: Brett, K. R., Lierman, A., & Turner, C. (2016. Lessons learned: A Primo usability study. Information Technology and Libraries, 35(1, 7-25. https://doi.org/10.6017/ital.v35i1.8965 Abstract Objective – To discover whether users can effectively complete common research tasks in a modified Primo Discovery System interface. Design – Usability testing. Setting – University of Houston Libraries. Subjects – Users of the University of Houston Libraries Ex Libris Primo Discovery System interface. Methods – The researchers used a think aloud usability test methodology, with participants asked to verbalize their thought processes as they completed a set of tasks. Four tasks were developed and divided into two task sets (Test 1 and Test 2, with session facilitators alternating sets for each participant. Tasks were as follows: locating a known article, finding a peer reviewed article on a requested subject, locating a book, and finding a newspaper article on a topic. Tests were conducted in front of the library entrance using a laptop equipped with Morae (screen and audio recording software, and participants were recruited via an assigned “caller” at the table offering library merchandise and food as a research incentive. Users could opt out of having their session recorded, resulting in a total of fifteen sessions completed with fourteen recorded. Thirteen of the fifteen participants were undergraduate students, one was a graduate student, one was a post-baccalaureate student, and there were no faculty participants. Facilitators completed notes on a standard rubric, coding participant responses into successes or failures and noting participant feedback. Main Results – All eight participants assigned Test 1 successfully completed Test 1, Task 1: locating a known article. Participants expressed a need for an author limiter in advanced search, and had difficulty using the citation formatted information to locate materials

  7. A usability evaluation of a SNOMED CT based compositional interface terminology for intensive care.

    Science.gov (United States)

    Bakhshi-Raiez, F; de Keizer, N F; Cornet, R; Dorrepaal, M; Dongelmans, D; Jaspers, M W M

    2012-05-01

    To evaluate the usability of a large compositional interface terminology based on SNOMED CT and the terminology application for registration of the reasons for intensive care admission in a Patient Data Management System. Observational study with user-based usability evaluations before and 3 months after the system was implemented and routinely used. Usability was defined by five aspects: effectiveness, efficiency, learnability, overall user satisfaction, and experienced usability problems. Qualitative (the Think-Aloud user testing method) and quantitative (the System Usability Scale questionnaire and Time-on-Task analyses) methods were used to examine these usability aspects. The results of the evaluation study revealed that the usability of the interface terminology fell short (SUS scores before and after implementation of 47.2 out of 100 and 37.5 respectively out of 100). The qualitative measurements revealed a high number (n=35) of distinct usability problems, leading to ineffective and inefficient registration of reasons for admission. The effectiveness and efficiency of the system did not change over time. About 14% (n=5) of the revealed usability problems were related to the terminology content based on SNOMED CT, while the remaining 86% (n=30) was related to the terminology application. The problems related to the terminology content were more severe than the problems related to the terminology application. This study provides a detailed insight into how clinicians interact with a controlled compositional terminology through a terminology application. The extensiveness, complexity of the hierarchy, and the language usage of an interface terminology are defining for its usability. Carefully crafted domain-specific subsets and a well-designed terminology application are needed to facilitate the use of a complex compositional interface terminology based on SNOMED CT. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. Commentary: Usability – A Sensitizing Concept

    DEFF Research Database (Denmark)

    Hertzum, Morten

    2018-01-01

    In his article “The Usability Construct: A Dead End?”, Tractinsky (in Human-Computer Interaction) contends that for scientific research on usability to progress, the usability construct should be unbundled and replaced by well-defined constructs. This contention is presented as the conclusion...... that follows naturally from taking a scientist’s viewpoint on usability. Similar calls for definitive concepts – constructs in Tractinsky’s terminology – have been made in other scientific fields with concepts as ambiguous as that of usability. But counterarguments have also been presented....

  9. Analysis in usability evaluations

    DEFF Research Database (Denmark)

    Følstad, Asbjørn; Lai-Chong Law, Effie; Hornbæk, Kasper

    2010-01-01

    While the planning and implementation of usability evaluations are well described in the literature, the analysis of the evaluation data is not. We present interviews with 11 usability professionals on how they conduct analysis, describing the resources, collaboration, creation of recommendations......, and prioritization involved. The interviews indicate a lack of structure in the analysis process and suggest activities, such as generating recommendations, that are unsupported by existing methods. We discuss how to better support analysis, and propose four themes for future research on analysis in usability...

  10. Usability in the lifecycle of medical software development

    Directory of Open Access Journals (Sweden)

    Trauzettel Franziska

    2016-09-01

    Full Text Available A close cooperation with users is necessary to ensure that interactive systems are robust, easy to use and accepted. Therefore, in medical technology, standards for usability are of fundamental importance. We investigated with the presented study how the concept of usability is currently understood and implemented in medical software companies. Interviews were conducted with 21 employees of German enterprises. Furthermore we extended an already existing quantitative online survey where 53 companies (including 24 from the health industry sector participated in. Results show that the importance of usability is recognized by most of the respondents. Moreover, a wide variety of methods and approaches is known and implemented for exploring user needs and evaluating system prototypes. However, it was observed that human-centered design activities mainly focus on functionality, risk prevention and accessibility. Hedonic user needs and subjective perceptions (“user experience” still play a minor role. Based on the results, practical requirements are derived and a “best case” for methodological approach is introduced.

  11. Mobile Usability

    DEFF Research Database (Denmark)

    Aryana, Bijan; Clemmensen, Torkil

    2013-01-01

    In this article, a country specific comparative mobile usability study is presented, using Iran and Turkey as the two chosen emerging/emergent nation exemplars of smartphone usage and adoption. In a focus group study, three mobile applications were selected by first-time users of smartphones...... personal contacts. The results and analysis establish the existence of country specific issues and concerns, as well as reveal generic usability issues. The article concludes that the source of these issues is most likely due to a combination of certain contextual features endemic to both Iran and Turkey...

  12. Ionizing radiation detection meter systems usability evaluation. Technical memorandum

    International Nuclear Information System (INIS)

    Severs, Y.; Hughes, R.; Tack, D.; Bossi, L.L.M.

    2002-12-01

    In support of the Canadian Forces Nuclear Detection, Identification and Dosimetry project a usability trial of three Ionizing Radiation Detection Meter Systems (IRDMS) was conducted 18-22 June 2001 at Connaught Ranges. The systems evaluated: System 1: ANPDR 77 Operational System with PDR 77 Alpha/Beta probes and GPS (Global Positioning System) Training System; System 2: ADM 300C Operational System with ABP 100 Alpha/Beta probes and GPS Training System, and System 3: RAM R200 Operational System with PA 100M and RG12 Alpha/Beta probes and GPS Training System. Twelve military personnel (Private to Captain) determined compliance with the bid evaluation criteria. The counter-balanced study, based on a Latin square design, was divided into two assessment phases, an operational phase and a training system phase, which rotated three groups (of four participants each) concurrently through each IRDMS. Groups were trained in set-up, maintenance and operation of each bid IRDMS prior to evaluation. The operational evaluation consisted of a test/maintenance stand, an indoor/outdoor operational stand, and an indoor,/outdoor training system stand. Participants rated the utility and usability of each system, by measuring case of use/maintenance under a range of relevant operational and clothing conditions, compatibility with soldier tasks, compatibility with clothing, compatibility with equipment and operational environments, and case of learning (including an assessment of initial and refresher training implications). A 7-point Likert-like acceptability rating scale, which covered a range from completely unacceptable (1) to completely acceptable (7), was used to evaluate the measures. The combined weighted mean scores were 584.3 for System 1 (70 o /b), 682.0 for System 2 (81 %) and 756.9 for System 3 (90%) out of a total possible score of 840. Participants reported mean scores for System 1 between barely unacceptable and borderline for both indoor and outdoor operations. System 2

  13. Ion-Responsive Drug Delivery Systems.

    Science.gov (United States)

    Yoshida, Takayuki; Shakushiro, Kohsuke; Sako, Kazuhiro

    2018-02-08

    Some kinds of cations and anions are contained in body fluids such as blood, interstitial fluid, gastrointestinal juice, and tears at relatively high concentration. Ionresponsive drug delivery is available to design the unique dosage formulations which provide optimized drug therapy with effective, safe and convenient dosing of drugs. The objective of the present review was to collect, summarize, and categorize recent research findings on ion-responsive drug delivery systems. Ions in body fluid/formulations caused structural changes of polymers/molecules contained in the formulations, allow formulations exhibit functions. The polymers/molecules responding to ions were ion-exchange resins/fibers, anionic or cationic polymers, polymers exhibiting transition at lower critical solution temperature, self-assemble supramolecular systems, peptides, and metalorganic frameworks. The functions of ion-responsive drug delivery systems were categorized to controlled drug release, site-specific drug release, in situ gelation, prolonged retention at the target sites, and enhancement of drug permeation. Administration of the formulations via oral, ophthalmic, transdermal, and nasal routes has showed significant advantages in the recent literatures. Many kinds of drug delivery systems responding to ions have been reported recently for several administration routes. Improvement and advancement of these systems can maximize drugs potential and contribute to patients in the world. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  14. The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System

    OpenAIRE

    Bailey, Timothy; Bode, Bruce W.; Christiansen, Mark P.; Klaff, Leslie J.; Alva, Shridhara

    2015-01-01

    Abstract Introduction: The purpose of the study was to evaluate the performance and usability of the FreeStyle? Libre? Flash glucose monitoring system (Abbott Diabetes Care, Alameda, CA) for interstitial glucose results compared with capillary blood glucose results. Materials and Methods: Seventy-two study participants with type 1 or type 2 diabetes were enrolled by four U.S. clinical sites. A sensor was inserted on the back of each upper arm for up to 14 days. Three factory-only calibrated s...

  15. To twist or poke? A method for identifying usability issues with the rotary controller and touch screen for control of in-vehicle information systems.

    Science.gov (United States)

    Harvey, Catherine; Stanton, Neville A; Pickering, Carl A; McDonald, Mike; Zheng, Pengjun

    2011-07-01

    In-vehicle information systems (IVIS) can be controlled by the user via direct or indirect input devices. In order to develop the next generation of usable IVIS, designers need to be able to evaluate and understand the usability issues associated with these two input types. The aim of this study was to investigate the effectiveness of a set of empirical usability evaluation methods for identifying important usability issues and distinguishing between the IVIS input devices. A number of usability issues were identified and their causal factors have been explored. These were related to the input type, the structure of the menu/tasks and hardware issues. In particular, the translation between inputs and on-screen actions and a lack of visual feedback for menu navigation resulted in lower levels of usability for the indirect device. This information will be useful in informing the design of new IVIS, with improved usability. STATEMENT OF RELEVANCE: This paper examines the use of empirical methods for distinguishing between direct and indirect IVIS input devices and identifying usability issues. Results have shown that the characteristics of indirect input devices produce more serious usability issues, compared with direct devices and can have a negative effect on the driver-vehicle interaction.

  16. Determination of the effectiveness of two methods for usability evaluation using a CPOE medication ordering system

    NARCIS (Netherlands)

    Khajouei, R.; Hasman, A.; Jaspers, M. W. M.

    2011-01-01

    Objectives: To assess the effectiveness of two usability evaluation methods, cognitive walkthrough (CW) and think aloud (TA), for identifying usability problems and to compare the performance of CW and TA in identifying different types of usability problems. Methods: A CW was performed by two

  17. Usability Evaluation of Public Web Mapping Sites

    Science.gov (United States)

    Wang, C.

    2014-04-01

    Web mapping sites are interactive maps that are accessed via Webpages. With the rapid development of Internet and Geographic Information System (GIS) field, public web mapping sites are not foreign to people. Nowadays, people use these web mapping sites for various reasons, in that increasing maps and related map services of web mapping sites are freely available for end users. Thus, increased users of web mapping sites led to more usability studies. Usability Engineering (UE), for instance, is an approach for analyzing and improving the usability of websites through examining and evaluating an interface. In this research, UE method was employed to explore usability problems of four public web mapping sites, analyze the problems quantitatively and provide guidelines for future design based on the test results. Firstly, the development progress for usability studies were described, and simultaneously several usability evaluation methods such as Usability Engineering (UE), User-Centered Design (UCD) and Human-Computer Interaction (HCI) were generally introduced. Then the method and procedure of experiments for the usability test were presented in detail. In this usability evaluation experiment, four public web mapping sites (Google Maps, Bing maps, Mapquest, Yahoo Maps) were chosen as the testing websites. And 42 people, who having different GIS skills (test users or experts), gender (male or female), age and nationality, participated in this test to complete the several test tasks in different teams. The test comprised three parts: a pretest background information questionnaire, several test tasks for quantitative statistics and progress analysis, and a posttest questionnaire. The pretest and posttest questionnaires focused on gaining the verbal explanation of their actions qualitatively. And the design for test tasks targeted at gathering quantitative data for the errors and problems of the websites. Then, the results mainly from the test part were analyzed. The

  18. A Comprehensive Review on: Transdermal drug delivery systems.

    OpenAIRE

    Kharat, Rekha; Bathe, Ritesh Suresh

    2016-01-01

    Transdermal drug delivery system was introduced to overcome the difficulties of drug delivery through oral route. Despite their relatively higher costs, transdermal delivery systems have proved advantageous for delivery of selected drugs, such as estrogens, testosterone, clonidine and nitro-glycerine. Transdermal delivery provides a leading edge over injectable and oral routes by increasing patient compliance and avoiding first pass metabolism respectively. Topical  administration  of  therap...

  19. Electronic Nicotine Delivery Systems Key Facts Infographic

    Data.gov (United States)

    U.S. Department of Health & Human Services — Explore the Electronic Nicotine Delivery Systems Key Facts Infographic which outlines key facts related to electronic nicotine delivery systems (ENDS), including...

  20. Performance Evaluation of Two Different Usability Evaluation Methods in the Context of Collaborative Writing Systems

    OpenAIRE

    Bakhtyar, Shoaib; Afridi, Qaisar Zaman

    2010-01-01

    In today’s world of rapid technological development one cannot deny the importance of collaborative writing systems. Besides many advantages of a collaborative writing system the major one is to allow its end users to work in collaboration with each other without having to physically meet. In the past various researches has been carried out for the usability evaluation of collaborative writing systems using the think aloud protocol method however there is no study conducted on the comparison ...

  1. Usability Analysis of Collision Avoidance System in Vehicle-to-Vehicle Communication Environment

    Directory of Open Access Journals (Sweden)

    Hong Cho

    2014-01-01

    Full Text Available Conventional intelligent vehicles have performance limitations owing to the short road and obstacle detection range of the installed sensors. In this study, to overcome this limitation, we tested the usability of a new conceptual autonomous emergency braking (AEB system that employs vehicle-to-vehicle (V2V communication technology in the existing AEB system. To this end, a radar sensor and a driving and communication environment constituting the AEB system were simulated; the simulation was then linked by applying vehicle dynamics and control logic. The simulation results show that the collision avoidance relaxation rate of V2V communication-based AEB system was reduced compared with that of existing vehicle-mounted-sensor-based system. Thus, a method that can lower the collision risk of the existing AEB system, which uses only a sensor cluster installed on the vehicle, is realized.

  2. Smart Drug Delivery Systems in Cancer Therapy.

    Science.gov (United States)

    Unsoy, Gozde; Gunduz, Ufuk

    2018-02-08

    Smart nanocarriers have been designed for tissue-specific targeted drug delivery, sustained or triggered drug release and co-delivery of synergistic drug combinations to develop safer and more efficient therapeutics. Advances in drug delivery systems provide reduced side effects, longer circulation half-life and improved pharmacokinetics. Smart drug delivery systems have been achieved successfully in the case of cancer. These nanocarriers can serve as an intelligent system by considering the differences of tumor microenvironment from healthy tissue, such as low pH, low oxygen level, or high enzymatic activity of matrix metalloproteinases. The performance of anti-cancer agents used in cancer diagnosis and therapy is improved by enhanced cellular internalization of smart nanocarriers and controlled drug release. Here, we review targeting, cellular internalization; controlled drug release and toxicity of smart drug delivery systems. We are also emphasizing the stimulus responsive controlled drug release from smart nanocarriers. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  3. Usability of a Wearable Camera System for Dementia Family Caregivers

    Directory of Open Access Journals (Sweden)

    Judith T. Matthews

    2015-01-01

    Full Text Available Health care providers typically rely on family caregivers (CG of persons with dementia (PWD to describe difficult behaviors manifested by their underlying disease. Although invaluable, such reports may be selective or biased during brief medical encounters. Our team explored the usability of a wearable camera system with 9 caregiving dyads (CGs: 3 males, 6 females, 67.00 ± 14.95 years; PWDs: 2 males, 7 females, 80.00 ± 3.81 years, MMSE 17.33 ± 8.86 who recorded 79 salient events over a combined total of 140 hours of data capture, from 3 to 7 days of wear per CG. Prior to using the system, CGs assessed its benefits to be worth the invasion of privacy; post-wear privacy concerns did not differ significantly. CGs rated the system easy to learn to use, although cumbersome and obtrusive. Few negative reactions by PWDs were reported or evident in resulting video. Our findings suggest that CGs can and will wear a camera system to reveal their daily caregiving challenges to health care providers.

  4. The effects of protoype medium on usability testing.

    Science.gov (United States)

    Boothe, Chase; Strawderman, Lesley; Hosea, Ethan

    2013-11-01

    Inconsistencies among testing methods and results in previous research prompted this study that builds upon a systematic usability testing research framework to better understand how interface medium influences users' abilities to detect usability flaws in applications. Interface medium was tested to identify its effects on users' perceptions of usability and abilities to detect usability problems and severe usability problems. Results indicated that medium has no effect on users' abilities to detect usability problems or perceptions of usability. However, results did indicate an interaction between the medium and the tested application in which users were able to identify significantly more usability problems on a higher fidelity medium using a particular application. Results also indicated that as users' perceptions of an application's usability increases, the users are less able to detect usability problems in that application. Usability testing should begin early in the design process, even if low fidelity mediums will be used. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  5. The Usability Expert’s Fear of Agility

    DEFF Research Database (Denmark)

    Nielsen, Lene; Madsen, Sabine

    2012-01-01

    This paper contributes to the HCI literature on usability practice with insights about the empirical challenges and global emerging practices caused by the advent of agile software development (ASD). In the paper we report from a worldwide study involving 12 usability professionals from 12...... different countries. The findings show that the usability professionals share a forced development and innovation in their practice that stem from their clients’ adoption and use of ASD methods. The ASD methods challenge the way usability testing is performed, the abilities of the usability expert......, the usability deliverables, and the experts’ assumptions about the importance of validity....

  6. Addressing security, collaboration, and usability with tactical edge mobile devices and strategic cloud-based systems

    Science.gov (United States)

    Graham, Christopher J.

    2012-05-01

    Success in the future battle space is increasingly dependent on rapid access to the right information. Faced with a shrinking budget, the Government has a mandate to improve intelligence productivity, quality, and reliability. To achieve increased ISR effectiveness, leverage of tactical edge mobile devices via integration with strategic cloud-based infrastructure is the single, most likely candidate area for dramatic near-term impact. This paper discusses security, collaboration, and usability components of this evolving space. These three paramount tenets outlined below, embody how mission information is exchanged securely, efficiently, with social media cooperativeness. Tenet 1: Complete security, privacy, and data integrity, must be ensured within the net-centric battle space. This paper discusses data security on a mobile device, data at rest on a cloud-based system, authorization and access control, and securing data transport between entities. Tenet 2: Lack of collaborative information sharing and content reliability jeopardizes mission objectives and limits the end user capability. This paper discusses cooperative pairing of mobile devices and cloud systems, enabling social media style interaction via tagging, meta-data refinement, and sharing of pertinent data. Tenet 3: Fielded mobile solutions must address usability and complexity. Simplicity is a powerful paradigm on mobile platforms, where complex applications are not utilized, and simple, yet powerful, applications flourish. This paper discusses strategies for ensuring mobile applications are streamlined and usable at the tactical edge through focused features sets, leveraging the power of the back-end cloud, minimization of differing HMI concepts, and directed end-user feedback.teInput=

  7. Supersaturating drug delivery systems

    DEFF Research Database (Denmark)

    Laitinen, Riikka; Löbmann, Korbinian; Grohganz, Holger

    2017-01-01

    of the bioavailability of poorly water-soluble drugs by increasing the driving force for drug absorption. However, ASDs often require a high weight percentage of carrier (usually a hydrophilic polymer) to ensure molecular mixing of the drug in the carrier and stabilization of the supersaturated state, often leading......Amorphous solid dispersions (ASDs) are probably the most common and important supersaturating drug delivery systems for the formulation of poorly water-soluble compounds. These delivery systems are able to achieve and maintain a sustained drug supersaturation which enables improvement...... strategy for poorly-soluble drugs. While the current research on co-amorphous formulations is focused on preparation and characterization of these systems, more detailed research on their supersaturation and precipitation behavior and the effect of co-formers on nucleation and crystal growth inhibition...

  8. Usability of light-emitting diodes in precision approach path indicator systems by individuals with marginal color vision.

    Science.gov (United States)

    2014-05-01

    To save energy, the FAA is planning to convert from incandescent lights to light-emitting diodes (LEDs) in : precision approach path indicator (PAPI) systems. Preliminary work on the usability of LEDs by color vision-waivered pilots (Bullough, Skinne...

  9. Usability Testing Of Web Mapping Portals

    Directory of Open Access Journals (Sweden)

    Petr Voldán

    2011-05-01

    Full Text Available This study presents a usability testing as method, which can be used to improve controlling of web map sites. Study refers to the basic principles of this method and describes particular usability tests of mapping sites. In this paper are identified potential usability problems of web sites: Amapy.cz, Google maps and Mapy.cz. The usability testing was focused on problems related with user interfaces, addresses searching and route planning of the map sites.

  10. An information management system for patients with tuberculosis: usability assessment with end-users.

    Science.gov (United States)

    Darby, Jonathan; Black, Jim; Morrison, David; Buising, Kirsty

    2012-01-01

    Information systems with clinical decision support (CDS) offer great potential to assist the co-ordination of patients with chronic diseases and to improve patient care. Despite this, few have entered routine clinical use. Tuberculosis (TB) is an infection of public health importance. It has complex interactions with many comorbid conditions, requires close supervised care and prolonged treatment for effective cure. These features make it suitable for use with an information management system with CDS features. In close consultation with key stakeholders, a clinical application was developed for the management of TB patients in Victoria. A formal usability assessment using semi-structured case-scenario based exercises was performed. Subjects were 12 individuals closely involved in the care of TB patients, including Infectious Diseases and Respiratory Physicians, and Public Health Nurses. Two researchers conducted the sessions, independently analysed responses and discrepancies compared to the voice record for validity. Despite varied computer experience, responses were positive regarding user interface and content. Data location was not always intuitive, however this improved with familiarity of the program. Decision support was considered valuable, with useful suggestions for expansion of these features. Automated reporting for correspondence and notification to the Health Department were felt worth the initial investment in data entry. An important workflow-based issue regarding dismissal of alerts and several errors were detected. Usability assessment validated many design elements of the system, provided a unique insight into workflow issues faced by users and hopefully will impact on its ultimate clinical utility.

  11. Methods and metrics challenges of delivery-system research

    Directory of Open Access Journals (Sweden)

    Alexander Jeffrey A

    2012-03-01

    Full Text Available Abstract Background Many delivery-system interventions are fundamentally about change in social systems (both planned and unplanned. This systems perspective raises a number of methodological challenges for studying the effects of delivery-system change--particularly for answering questions related to whether the change will work under different conditions and how the change is integrated (or not into the operating context of the delivery system. Methods The purpose of this paper is to describe the methodological and measurement challenges posed by five key issues in delivery-system research: (1 modeling intervention context; (2 measuring readiness for change; (3 assessing intervention fidelity and sustainability; (4 assessing complex, multicomponent interventions; and (5 incorporating time in delivery-system models to discuss recommendations for addressing these issues. For each issue, we provide recommendations for how research may be designed and implemented to overcome these challenges. Results and conclusions We suggest that a more refined understanding of the mechanisms underlying delivery-system interventions (treatment theory and the ways in which outcomes for different classes of individuals change over time are fundamental starting points for capturing the heterogeneity in samples of individuals exposed to delivery-system interventions. To support the research recommendations outlined in this paper and to advance understanding of the "why" and "how" questions of delivery-system change and their effects, funding agencies should consider supporting studies with larger organizational sample sizes; longer duration; and nontraditional, mixed-methods designs. A version of this paper was prepared under contract with the Agency for Healthcare Research and Quality (AHRQ, US Department of Health and Human Services for presentation and discussion at a meeting on "The Challenge and Promise of Delivery System Research," held in Sterling, VA, on

  12. An Evaluation of the Usability of a Computerized Decision Support System for Nursing Homes

    Science.gov (United States)

    Fossum, M.; Ehnfors, M.; Fruhling, A.; Ehrenberg, A.

    2011-01-01

    Background Computerized decision support systems (CDSSs) have the potential to significantly improve the quality of nursing care of older people by enhancing the decision making of nursing personnel. Despite this potential, health care organizations have been slow to incorporate CDSSs into nursing home practices. Objective This study describes facilitators and barriers that impact the ability of nursing personnel to effectively use a clinical CDSS for planning and treating pressure ulcers (PUs) and malnutrition and for following the suggested risk assessment guidelines for the care of nursing home residents. Methods We employed a qualitative descriptive design using varied methods, including structured group interviews, cognitive walkthrough observations and a graphical user interface (GUI) usability evaluation. Group interviews were conducted with 25 nursing personnel from four nursing homes in southern Norway. Five nursing personnel participated in cognitive walkthrough observations and the GUI usability evaluation. Text transcripts were analyzed using qualitative content analysis. Results Group interview participants reported that ease of use, usefulness and a supportive work environment were key facilitators of CDSS use. The barriers identified were lack of training, resistance to using computers and limited integration of the CDSS with the facility’s electronic health record (EHR) system. Key findings from the usability evaluation also identified the difficulty of using the CDSS within the EHR and the poorly designed GUI integration as barriers. Conclusion Overall, we found disconnect between two types of nursing personnel. Those who were comfortable with computer technology reported positive feedback about the CDSS, while others expressed resistance to using the CDSS for various reasons. This study revealed that organizations must invest more resources in educating nursing personnel on the seriousness of PUs and poor nutrition in the elderly, providing

  13. From an expert-driven paper guideline to a user-centred decision support system: a usability comparison study

    NARCIS (Netherlands)

    Kilsdonk, Ellen; Peute, Linda W.; Riezebos, Rinke J.; Kremer, Leontien C.; Jaspers, Monique W. M.

    2013-01-01

    To assess whether a user-centred prototype clinical decision support system (CDSS) providing patient-specific advice better supports healthcare practitioners in terms of (a) types of usability problems detected and (b) effective and efficient retrieval of childhood cancer survivor's follow-up

  14. Complementary role of two evaluation methods in the usability and accessibility evaluation of a non-standard system

    CSIR Research Space (South Africa)

    Adebesin, F

    2010-10-01

    Full Text Available and used by people with varying abilities. Although accessibility concerns are aimed at making systems usable for people with disabilities, support for direct accessibility, the built-in redundancies in an application that enable as many people as possible...

  15. A Pedagogical Approach toward Teaching an Information Systems Student How to Conduct a Web Usability Study for an Honors Project: A Case Study

    Science.gov (United States)

    Jesse, Gayle

    2013-01-01

    The purpose of this paper is to provide educators with a course model and pedagogy to teach a computer information systems usability course. This paper offers a case study based on an honors student project titled "Web Usability: Phases of Developing an Interactive Event Database." Each individual phase--creating a prototype along with…

  16. Recent Trends of Polymer Mediated Liposomal Gene Delivery System

    Directory of Open Access Journals (Sweden)

    Shyamal Kumar Kundu

    2014-01-01

    Full Text Available Advancement in the gene delivery system have resulted in clinical successes in gene therapy for patients with several genetic diseases, such as immunodeficiency diseases, X-linked adrenoleukodystrophy (X-ALD blindness, thalassemia, and many more. Among various delivery systems, liposomal mediated gene delivery route is offering great promises for gene therapy. This review is an attempt to depict a portrait about the polymer based liposomal gene delivery systems and their future applications. Herein, we have discussed in detail the characteristics of liposome, importance of polymer for liposome formulation, gene delivery, and future direction of liposome based gene delivery as a whole.

  17. Usability Methods for Ensuring Health Information Technology Safety: Evidence-Based Approaches. Contribution of the IMIA Working Group Health Informatics for Patient Safety.

    Science.gov (United States)

    Borycki, E; Kushniruk, A; Nohr, C; Takeda, H; Kuwata, S; Carvalho, C; Bainbridge, M; Kannry, J

    2013-01-01

    Issues related to lack of system usability and potential safety hazards continue to be reported in the health information technology (HIT) literature. Usability engineering methods are increasingly used to ensure improved system usability and they are also beginning to be applied more widely for ensuring the safety of HIT applications. These methods are being used in the design and implementation of many HIT systems. In this paper we describe evidence-based approaches to applying usability engineering methods. A multi-phased approach to ensuring system usability and safety in healthcare is described. Usability inspection methods are first described including the development of evidence-based safety heuristics for HIT. Laboratory-based usability testing is then conducted under artificial conditions to test if a system has any base level usability problems that need to be corrected. Usability problems that are detected are corrected and then a new phase is initiated where the system is tested under more realistic conditions using clinical simulations. This phase may involve testing the system with simulated patients. Finally, an additional phase may be conducted, involving a naturalistic study of system use under real-world clinical conditions. The methods described have been employed in the analysis of the usability and safety of a wide range of HIT applications, including electronic health record systems, decision support systems and consumer health applications. It has been found that at least usability inspection and usability testing should be applied prior to the widespread release of HIT. However, wherever possible, additional layers of testing involving clinical simulations and a naturalistic evaluation will likely detect usability and safety issues that may not otherwise be detected prior to widespread system release. The framework presented in the paper can be applied in order to develop more usable and safer HIT, based on multiple layers of evidence.

  18. The Impact of CPOE Medication Systems' Design Aspects on Usability, Workflow and Medication Orders A Systematic Review

    NARCIS (Netherlands)

    Khajouei, R.; Jaspers, M. W. M.

    2010-01-01

    Objectives: To examine the impact of design aspects of computerized physician order entry (CPOE) systems for medication ordering on usability, physicians' workflow and on medication orders. Methods: We systematically searched Pub-Med, EMBASE and Ovid MEDLINE for articles published from 1986 to 2007.

  19. An Intelligent Framework for Website Usability

    Directory of Open Access Journals (Sweden)

    Alexiei Dingli

    2014-01-01

    Full Text Available With the major advances of the Internet throughout the past couple of years, websites have come to play a central role in the modern marketing business program. However, simply owning a website is not enough for a business to prosper on the Web. Indeed, it is the level of usability of a website that determines if a user stays or abandons it for another competing one. It is therefore crucial to understand the importance of usability on the web, and consequently the need for its evaluation. Nonetheless, there exist a number of obstacles preventing software organizations from successfully applying sound website usability evaluation strategies in practice. From this point of view automation of the latter is extremely beneficial, which not only assists designers in creating more usable websites, but also enhances the Internet users’ experience on the Web and increases their level of satisfaction. As a means of addressing this problem, an Intelligent Usability Evaluation (IUE tool is proposed that automates the usability evaluation process by employing a Heuristic Evaluation technique in an intelligent manner through the adoption of several research-based AI methods. Experimental results show there exists a high correlation between the tool and human annotators when identifying the considered usability violations.

  20. The Impact of Mobile TradeManager on Fashion Product Sales: From Usability Perspective

    Directory of Open Access Journals (Sweden)

    Zilong Liu

    2014-01-01

    Full Text Available The competition in fashion and textiles (FTs industry is strong. Enterprises have to compete at all levels and need to adapt to the mobile commerce (MC context. Mobile TradeManager (MTM is a typical MC application and good use of it will facilitate the sales of FTs products. Plenty of prior studies on MC were developed to discuss the subjective beliefs. Motivated by the research that appeals for more attention to IT artifact itself, this paper integrates the system usability of MC into the behavioral model. To this end, the purpose of this study is twofold: (a to identify the impact of MTM usability on consumers’ online shopping behavior of FTs production, and (b to explore and understand how usability of MTM could be improved. Data analysis, based on a survey of 837 MTM users, reveals that perceived entertainment, MTM system usability, subjective norm, and consumer’s self-efficacy significantly affect individual’s intention to use MTM. Meanwhile, it is revealed that MTM usability is a joint function of mobile device’s system performance, WAP website’s design, and the characteristics of wireless communication networks.

  1. Managing Product Usability: How companies deal with usability in the development of electronic consumer products

    OpenAIRE

    Van Kuijk, J.I.

    2010-01-01

    Problem statement: Even though there is a large amount of methods for user-centred design, the usability of electronic consumer products (e.g., portable music players, washing machines and mobile phones) is under pressure. Usability is the extent to which a product can be used by specified users to achieve specified goals with effectiveness, efficiency and satisfaction in a specified context of use. That the usability of electronic consumer products is under pressure is attributed to an incre...

  2. Problem Prioritization in Usability Evaluation:

    DEFF Research Database (Denmark)

    Hertzum, Morten

    2006-01-01

    Severity assessments enable prioritization of problems encountered during usability evaluations and thereby provide a device for guiding the utilization of design resources. However, designers' response to usability evaluations is also influenced by other factors, which may overshadow severity....... With the purpose of enhancing the impact of severity assessments, this study combines a field study of factors that influence the impact of evaluations with an experimental study of severity assessments made during usability inspections. The results show that even in a project receptive to input from evaluations...... their impact was highly dependent on conducting evaluations early. This accorded with an informal method that blended elements of usability evaluation and participatory design and could be extended with user-made severity assessments. The major cost associated with the evaluations was not finding but fixing...

  3. Neuroanatomical correlates of perceived usability

    DEFF Research Database (Denmark)

    Vi, Chi Thanh; Hornbæk, Kasper; Subramanian, Sriram

    2017-01-01

    Usability has a distinct subjective component, yet surprisingly little is known about its neural basis and relation to the neuroanatomy of aesthetics. To begin closing this gap, we conducted two functional magnetic resonance imaging studies in which participants were shown static webpages (in...... the first study) and videos of interaction with webpages (in the second study). The webpages were controlled so as to exhibit high and low levels of perceived usability and perceived aesthetics. Our results show unique links between perceived usability and brain areas involved in functions such as emotional...... processing (left fusiform gyrus, superior frontal gyrus), anticipation of physical interaction (precentral gyrus), task intention (anterior cingulate cortex), and linguistic processing (medial and bilateral superior frontal gyri). We use these findings to discuss the brain correlates of perceived usability...

  4. Supporting Usability Engineering in Small Software Development Organizations

    DEFF Research Database (Denmark)

    Bornoe, Nis; Stage, Jan

    2013-01-01

    Despite an interest and use of different usability engineering methods small software development organizations find it challenging to implement usability engineering into the software development process. We present the results from a study about usability engineering in practice. Through a series...... of semistructured interviews we want to get an understanding of how usability is implemented into the organizations and how it’s practiced in reality. We found that the developers found it problematic to combine agile software development methods with classic usability engineering methods. A lack of solid usability...... engineering expertise and not least experience seems to be a main obstacle for a successful implementation of usability engineering into current software development practices. They are requesting methods and procedures that fit better with their current practices and strategies to implement usability...

  5. Stimuli-Responsive Polymeric Systems for Controlled Protein and Peptide Delivery: Future Implications for Ocular Delivery.

    Science.gov (United States)

    Mahlumba, Pakama; Choonara, Yahya E; Kumar, Pradeep; du Toit, Lisa C; Pillay, Viness

    2016-07-30

    Therapeutic proteins and peptides have become notable in the drug delivery arena for their compatibility with the human body as well as their high potency. However, their biocompatibility and high potency does not negate the existence of challenges resulting from physicochemical properties of proteins and peptides, including large size, short half-life, capability to provoke immune responses and susceptibility to degradation. Various delivery routes and delivery systems have been utilized to improve bioavailability, patient acceptability and reduce biodegradation. The ocular route remains of great interest, particularly for responsive delivery of macromolecules due to the anatomy and physiology of the eye that makes it a sensitive and complex environment. Research in this field is slowly gaining attention as this could be the breakthrough in ocular drug delivery of macromolecules. This work reviews stimuli-responsive polymeric delivery systems, their use in the delivery of therapeutic proteins and peptides as well as examples of proteins and peptides used in the treatment of ocular disorders. Stimuli reviewed include pH, temperature, enzymes, light, ultrasound and magnetic field. In addition, it discusses the current progress in responsive ocular drug delivery. Furthermore, it explores future prospects in the use of stimuli-responsive polymers for ocular delivery of proteins and peptides. Stimuli-responsive polymers offer great potential in improving the delivery of ocular therapeutics, therefore there is a need to consider them in order to guarantee a local, sustained and ideal delivery of ocular proteins and peptides, evading tissue invasion and systemic side-effects.

  6. Usability: a critical success factor for managing change in the clinical info-structure.

    Science.gov (United States)

    Kay, S

    2005-06-01

    There can be no doubt that the clinical info-structure is being significantly enriched with the deployment of new systems throughout the health sector. From a technological perspective, the initial emphasis has been mainly on functionality and only latterly on the usability of these clinical information systems. However, the large scale and rapid pace of the changes being wrought in the health sector will have a major impact on clinicians and patients, not least in how they interact with the technology. Therefore, it is not only hardware and software but people-ware, too, that needs to be actively managed; not simply a one-off functional specification but an ongoing, complex relationship. Usability is the human factor that encompasses the ethical, educational, and evaluative aspects of design. There is also a strong case for regarding usability of clinical information systems as a key critical success factor for the management of change within the health-care domain. In particular, the relationship between usability, and education and training is examined.

  7. Development of a Customizable Health IT Usability Evaluation Scale

    Science.gov (United States)

    Yen, Po-Yin; Wantland, Dean; Bakken, Suzanne

    2010-01-01

    We developed a customizable questionnaire, the Health Information Technology (IT) Usability Evaluation Scale (Health-ITUES) and conducted an exploratory factor analysis to examine the scale’s psychometric properties. Nurses (n=377) completed Health-ITUES to rate the usability of a web-based communication system for scheduling nursing staff. The analysis revealed a four-factor structure of Health-ITUES. The results provided preliminary evidence for the factorial validity and internal consistency reliability of Health-ITUES. PMID:21347112

  8. Advancing Usability Evaluation through Human Reliability Analysis

    International Nuclear Information System (INIS)

    Ronald L. Boring; David I. Gertman

    2005-01-01

    This paper introduces a novel augmentation to the current heuristic usability evaluation methodology. The SPAR-H human reliability analysis method was developed for categorizing human performance in nuclear power plants. Despite the specialized use of SPAR-H for safety critical scenarios, the method also holds promise for use in commercial off-the-shelf software usability evaluations. The SPAR-H method shares task analysis underpinnings with human-computer interaction, and it can be easily adapted to incorporate usability heuristics as performance shaping factors. By assigning probabilistic modifiers to heuristics, it is possible to arrive at the usability error probability (UEP). This UEP is not a literal probability of error but nonetheless provides a quantitative basis to heuristic evaluation. When combined with a consequence matrix for usability errors, this method affords ready prioritization of usability issues

  9. The reliability and usability of district health information software ...

    African Journals Online (AJOL)

    The reliability and usability of district health information software: case studies from Tanzania. ... The District Health Information System (DHIS) software from the Health Information System ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  10. The Research Progress of Targeted Drug Delivery Systems

    Science.gov (United States)

    Zhan, Jiayin; Ting, Xizi Liang; Zhu, Junjie

    2017-06-01

    Targeted drug delivery system (DDS) means to selectively transport drugs to targeted tissues, organs, and cells through a variety of drugs carrier. It is usually designed to improve the pharmacological and therapeutic properties of conventional drugs and to overcome problems such as limited solubility, drug aggregation, poor bio distribution and lack of selectivity, controlling drug release carrier and to reduce normal tissue damage. With the characteristics of nontoxic and biodegradable, it can increase the retention of drug in lesion site and the permeability, improve the concentration of the drug in lesion site. at present, there are some kinds of DDS using at test phase, such as slow controlled release drug delivery system, targeted drug delivery systems, transdermal drug delivery system, adhesion dosing system and so on. This paper makes a review for DDS.

  11. A study on nanodiamond-based drug delivery system

    International Nuclear Information System (INIS)

    Li Jing; Zhang Xiaoyong; Zhu Ying; Li Wenxin; Huang Qing

    2010-01-01

    A multifunctional drug delivery system based on nanodiamonds (NDs) has been developed. FITC, HCPT and TF were absorbed on NDs successively to form the multifunctional complex. The NDs and ND complex samples were characterized by TEM, FR-IR and UV-V. The results indicated that this drug delivery system is a high loading system. Efficacy of the drug delivery system on Hela cell was evaluated with MTT assays and fluorescence microscopy. The results show that multifunction of the NDs complex include fluorescence, targeting and high efficacy. (authors)

  12. Exploring the Usability of Mobile Apps Supporting Radiologists' Training in Diagnostic Decision Making.

    Science.gov (United States)

    Kim, Min Soon; Aro, Michael R; Lage, Kraig J; Ingalls, Kevin L; Sindhwani, Vivek; Markey, Mia K

    2016-03-01

    The objective of this study was to conduct a usability evaluation of mobile apps for supporting education and training in radiologic diagnostic decision-making processes. Of 381 mobile apps available at two major stores (Google Play and iTunes), eight iOS apps were selected for laboratory-based usability tests. Six staff radiologists completed eight app-specific task sets, using a think-aloud strategy. The triangular methods approach included quantitative performance measures, System Usability Scale (SUS), and qualitative thematic analysis using heuristic usability principles of usability issues. Overall, radiologists achieved higher than 70% success, with favorable SUS scores, in completing the tasks for seven of the eight apps. However, task success rate and SUS score had a weak relation (r = 0.23), indicating that the perceived usability may not reflect the holistic usability of the app. Task analysis and self-report revealed 108 usability issues, which were condensed to 55 unique issues and categorized by nine usability themes and mapped to ten usability heuristics. Nonintuitive functionality (eg, nonintuitive or misleading labels) was the most frequent theme observed, leading to inefficient navigation. These usability findings were consistent with the 13 improvements the radiologists suggested. This study demonstrates the feasibility of usability evaluation of radiology mobile apps and suggests potential improvements in the development of radiology mobile apps. This study also suggests that proficiency with mobile devices may not be equivalent to being an expert user, proficient in using the apps. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Elastin-Like Recombinamers As Smart Drug Delivery Systems.

    Science.gov (United States)

    Arias, F Javier; Santos, Mercedes; Ibanez-Fonseca, Arturo; Pina, Maria Jesus; Serrano, Sofía

    2018-02-19

    Drug delivery systems that are able to control the release of bioactive molecules and designed to carry drugs to target sites are of particular interest for tissue therapy. Moreover, systems comprising materials that can respond to environmental stimuli and promote self-assembly and higher order supramolecular organization are especially useful in the biomedical field. Objetive: This review focuses on biomaterials suitable for this purpose and that include elastin-like recombinamers (ELRs), a class of proteinaceous polymers bioinspired by natural elastin, designed using recombinant technologies. The self-assembly and thermoresponsive behaviour of these systems, along with their biodegradability, biocompatibility and well-defined composition as a result of their tailormade design, make them particularly attractive for controlled drug delivery. ELR-based delivery systems that allow targeted delivery are reviewed, especially ELR-drug recombinant fusion constructs, ELR-drug systems chemically bioconjugated in their monomeric and soluble forms, and drug encapsulation by nanoparticle-forming ELRs. Subsequently, the review focuses on those drug carriers in which smart release is triggered by pH or temperature with a particular focus on cancer treatments. Systems for controlled drug release based on depots and hydrogels that act as both a support and reservoir in which drugs can be stored will be described, and their applications in drug delivery discussed. Finally, smart drug-delivery systems not based on ELRs, including those comprising proteins, synthetic polymers and non-polymeric systems, will also be briefly discussed. Several different constructions based on ELRs are potential candidates for controlled drug delivery to be applied in advanced biomedical treatments. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  14. A microfluidic control system with re-usable micropump/valve actuator and injection moulded disposable polymer lab-on-a-slide

    DEFF Research Database (Denmark)

    Bu, Minqiang; Perch-Nielsen, Ivan R.; Yi, Sun

    2011-01-01

    A microfluidic control system consisting of micropump/valves with a re-usable pneumatic actuator and a disposable polymer lab-on-a-slide is presented. The lab-on-a-slide was fabricated using low cost methods, such as injection moulding of TOPAS® cyclic olefin copolymer (COC) slide, lamination...... of different layers of polymer, and ultrasonic welding of TOPAS® lid to the slide. The re-usable pneumatic actuator not only simplifies the design of the lab-on-a-slide and reduces the fabrication cost, but also reduces the possibility of cross contamination during replacement of the disposable lab...

  15. Recent trends in challenges and opportunities of Transdermal drug delivery system

    OpenAIRE

    P.M.Patil; P.D.Chaudhari; Jalpa K.Patel; K.A.Kedar; P.P.Katolkar

    2012-01-01

    Drug delivery system relates to the production of a drug, its delivery medium, and the way of administration. Drug delivery systems are even used for administering nitroglycerin. Transdermal drug delivery system is the system in which the delivery of the active ingredients of the drug occurs by the means of skin. Various types of transdermal patches are used. There are various methods to enhance the transdermal drug delivery system. But using microfabricated microneedles drugs are delivered v...

  16. Measurement properties and usability of non-contact scanners for measuring transtibial residual limb volume.

    Science.gov (United States)

    Kofman, Rianne; Beekman, Anna M; Emmelot, Cornelis H; Geertzen, Jan H B; Dijkstra, Pieter U

    2018-06-01

    Non-contact scanners may have potential for measurement of residual limb volume. Different non-contact scanners have been introduced during the last decades. Reliability and usability (practicality and user friendliness) should be assessed before introducing these systems in clinical practice. The aim of this study was to analyze the measurement properties and usability of four non-contact scanners (TT Design, Omega Scanner, BioSculptor Bioscanner, and Rodin4D Scanner). Quasi experimental. Nine (geometric and residual limb) models were measured on two occasions, each consisting of two sessions, thus in total 4 sessions. In each session, four observers used the four systems for volume measurement. Mean for each model, repeatability coefficients for each system, variance components, and their two-way interactions of measurement conditions were calculated. User satisfaction was evaluated with the Post-Study System Usability Questionnaire. Systematic differences between the systems were found in volume measurements. Most of the variances were explained by the model (97%), while error variance was 3%. Measurement system and the interaction between system and model explained 44% of the error variance. Repeatability coefficient of the systems ranged from 0.101 (Omega Scanner) to 0.131 L (Rodin4D). Differences in Post-Study System Usability Questionnaire scores between the systems were small and not significant. The systems were reliable in determining residual limb volume. Measurement systems and the interaction between system and residual limb model explained most of the error variances. The differences in repeatability coefficient and usability between the four CAD/CAM systems were small. Clinical relevance If accurate measurements of residual limb volume are required (in case of research), modern non-contact scanners should be taken in consideration nowadays.

  17. Online user tracking and usability tools - a mapping study

    OpenAIRE

    Nyström, Niklas

    2014-01-01

    Tracking user activities online can be done in order to improve systems usability, understand user behaviour or to increase monetary prot, to mention a few things. The software tools for this purpose can vary, for example in terms of usability of the tool itself, features, security, price, accessibility and support options. In this study I have developed a methodology to evaluate a selection of modern tools and map them depending on various properties. I have also analysed learning theories t...

  18. Usability and Interaction Design in West Africa

    DEFF Research Database (Denmark)

    Sørensen, Jannick Kirk

    Good usability is important in all ICT solutions. To achieve good usability, a good praxis for interaction design is needed. Usability and interaction design have however emerged and established itself in a North European and US context. The ICT industry in Africa do not have the same resources...... for user-involvement and participatory design be directly transferred? How can interaction design and usability be cared for in African ICT development context, given the resources available? This paper aims to initiate a discussion of the conditions for interaction design and usability in West Africa...... in the field of interaction design as in the developed world. While good usability and good user experiences are important to all users of ICT, the question is whether the methods and techniques that were mainly developed in Scandinavia, Europe and US are suitable for ICT development in Africa? Can ideals...

  19. VoIP Accessibility: A Usability Study of Voice over Internet Protocol (VoIP) Systems and A Survey of VoIP Users with Vision Loss

    Science.gov (United States)

    Packer, Jaclyn; Reuschel, William

    2018-01-01

    Introduction: Accessibility of Voice over Internet Protocol (VoIP) systems was tested with a hands-on usability study and an online survey of VoIP users who are visually impaired. The survey examined the importance of common VoIP features, and both methods assessed difficulty in using those features. Methods: The usability test included four paid…

  20. An approach to the efficient assessment of safety and usability of computer based control systems, VeNuS 2. Global final report

    International Nuclear Information System (INIS)

    Nelke, T.; Dlugosch, C.; Olaverri Monreal, C.; Sachse, K.; Thuering, M.

    2015-01-01

    Prior to the use of computer-based instrumentation and control the evidence of sufficient safety, development methods and the suitability of man-machine interface must be provided. For this purpose, validation methods must be available, if possible supported by appropriate tools. Based on the multitude of the data which has to be taken into account it is important to generate technical documentation, to realize efficient operation and to prevent human based errors. An approach for computer based generation of user manuals for the operation of technical systems was developed in the VeNuS 2 project. A second goal was to develop an approach to evaluate the usability of safety relevant digital human-machine-interfaces (e.g. for nuclear industries). Therefore a software tool has been developed to assess aspects of usability of user interfaces by considering safety-related priorities. Additionally new or well known methods for provision of evidence of sufficient safety and usability for computer based systems shall be developed in a prototyped way.

  1. Qualitative Marketing Research Through Usability Testing

    Directory of Open Access Journals (Sweden)

    Orzan Mihai

    2008-04-01

    Full Text Available Usability is an attribute of any good product, just as its functionality. It refers mainly to the utility of a product for its indented users, as well as to its ease of use. And whilst a correct functionality is critical for the commercial success of any product, its value comes through the human needs that it fulfills, which is determined through various marketing research techniques. In parallel, the IT&C community has developed in the last two decades its own type of research, called usability testing, used mainly to evaluate interface ease of use and all usability problems associated with.software products. This article aims at finding the right place for usability testing and usability professionals in the marketing community, as well as drawing a wider picture, from a marketing research perspective, on one of the most popular topics in IT&C community for the benefit of marketing scholars and professionals.

  2. Review of Spatial-Database System Usability: Recommendations for the ADDNS Project

    National Research Council Canada - National Science Library

    Abdalla, R. M; Niall, K. K

    2007-01-01

    ...) and three-dimensional (3D) visualizations. This report presents an overview of the basic concepts of GIS and spatial databases, provides an analytical usability evaluation and critically analyses different spatial- database applications...

  3. Understanding Usability Work as a Human Activity

    DEFF Research Database (Denmark)

    Nørgaard, Mie

    Three core themes are explored in eight papers: Usability work as a human activity, usability practice and methods, and persuasiveness of evaluation results and feedback. We explore how usability work is much more than methods and work procedures, and argue that maturing our understanding...

  4. Usability of synchronization for cognitive modeling

    International Nuclear Information System (INIS)

    Diebner, Hans H.; Grond, Florian

    2005-01-01

    We discuss the synchronization features of a previously introduced adaptive system for dynamics recognition in more detail. We investigate the usability of synchronization for modeling and parameter estimations. It is pointed out inhowfar the adaptive system based on synchronization can become a powerful tool in modeling. The adaptive system can store modules of pre-adapted dynamics and is potentially capable of undergoing self-modification. We compare the stored modules with pre-knowledge that a modeler puts into his or her models. In this sense the adaptive system functions like an expert system

  5. Usability analysis of industrial cooking equipment.

    Science.gov (United States)

    Calado, Alexana Vilar Soares; Soares, Marcelo Márcio

    2012-01-01

    This paper refers to the comparative study of the equipment used for cooking in commercial of kitchens restaurants that use the system of traditional cooking and those ones which use the system called smart cooking (combination oven). The study investigates the usability issues concerning to the two systems, analyzing comparatively the aspects related to anthropometry, dimensional variables, the use of the product and also the product safety, as well as issues of information related to operation of the new concepts of cooking in intelligent systems.

  6. Auditing Information System : Delivery Product Service

    Directory of Open Access Journals (Sweden)

    Purwoko Purwoko

    2011-05-01

    Full Text Available Purpose of the research is to ensure the securities of information system asset and to ensure if informa-tion system support the operational and data collected was valid. Research method that used in this research were library studies and field studies. Field studies such an observation, questioner, and inter-view. the expected result are founding the weakness of security management control, operational man-agement control, input control, and output control of risk happened in the company. Conclusion of this research are the system on the company work good and there’s no potential risk happened and make an impact to the delivery process of information system.Index Terms - Auditing Information system, Delivery product process.

  7. Drug delivery from the oral cavity: a focus on mucoadhesive buccal drug delivery systems.

    Science.gov (United States)

    Shinkar, Dattatraya Manohar; Dhake, Avinash Sridhar; Setty, Chitral Mallikarjuna

    2012-01-01

    Since the early 1980s the concept of mucoadhesion has gained considerable interest in pharmaceutical technology. The various advantages associated with these systems made buccal drug delivery as a novel route of drug administration. It prolongs the residence time of the dosage form at the site of application. These systems remain in close contact with the absorption tissue, the mucous membrane, and thus contribute to improved and/or better therapeutic performance of the drug and of both local and systemic effects. This review highlights the anatomy and structure of oral mucosa, mechanism and theories of mucoadhesion, factors affecting mucoadhesion, characteristics and properties of desired mucoadhesive polymers, various types of dosage forms, and general considerations in design of mucoadhesive buccal dosage forms, permeation enhancers, and evaluation methods. Over the past few decades the mucoadhesive buccal drug delivery system has received a great deal of attention to develop mucoadhesive dosage forms to enable the prolonged retention at the site of action, providing a controlled release of drug for improved therapeutic outcome. Mucoadhesive drug delivery gives facility to include a permeation enhancer/enzyme inhibitor or pHmodifier in the formulation and versatility in designing as multidirectional or unidirectional release systems for local and systemic action. Local delivery to tissues of the oral cavity has a number of applications, including treatment of local conditions such as periodontal disease, bacterial and fungal infections, and aphthous stomatitis and vesiculo bullous diseases. For the treatment of chronic diseases, the mucoadhesive buccal drug delivery system allows easily accessibility and is generally well-accepted for administeringdrugs by systemic action.

  8. A real-time virtual delivery system for photon radiotherapy delivery monitoring

    Directory of Open Access Journals (Sweden)

    Feng Shi

    2014-03-01

    Full Text Available Purpose: Treatment delivery monitoring is important for radiotherapy, which enables catching dosimetric error at the earliest possible opportunity. This project develops a virtual delivery system to monitor the dose delivery process of photon radiotherapy in real-time using GPU-based Monte Carlo (MC method.Methods: The simulation process consists of 3 parallel CPU threads. A thread T1 is responsible for communication with a linac, which acquires a set of linac status parameters, e.g. gantry angles, MLC configurations, and beam MUs every 20 ms. Since linac vendors currently do not offer interface to acquire data in real time, we mimic this process by fetching information from a linac dynalog file at the set frequency. Instantaneous beam fluence map (FM is calculated based. A FM buffer is also created in T1 and the instantaneous FM is accumulated to it. This process continues, until a ready signal is received from thread T2 on which an in-house developed MC dose engine executes on GPU. At that moment, the accumulated FM is transferred to T2 for dose calculations, and the FM buffer in T1 is cleared. Once the dose calculation finishes, the resulting 3D dose distribution is directed to thread T3, which displays it in three orthogonal planes in color wash overlaid on the CT image. This process continues to monitor the 3D dose distribution in real-time.Results: An IMRT and a VMAT cases used in our patient-specific QA are studied. Maximum dose differences between our system and treatment planning system are 0.98% and 1.58% for the IMRT and VMAT cases, respectively. The update frequency is >10Hz and the relative uncertainty level is 2%.Conclusion: By embedding a GPU-based MC code in a novel data/work flow, it is possible to achieve real-time MC dose calculations to monitor delivery process.------------------------------Cite this article as: Shi F, Gu X, Graves YJ, Jiang S, Jia X. A real-time virtual delivery system for photon radiotherapy delivery

  9. Distance Synchronous Information Systems Course Delivery

    Science.gov (United States)

    Peslak, Alan R.; Lewis, Griffith R.; Aebli, Fred

    2014-01-01

    Teaching computer information systems via distance education is a challenge for both student and faculty. Much research work has been performed on methods of teaching via distance education. Today we are faced with a variety of options for course delivery. Asynchronous delivery via online or lesson instruction still remains most common. But…

  10. Increasing the impact of usability work in software development

    DEFF Research Database (Denmark)

    Uldall-Espersen, Tobias; Frøkjær, Erik

    2006-01-01

    Usability, Case Study, Software Engineering, Software Quality, Organizational Impact, Usability Requirement Management, CHI 2007 workshop......Usability, Case Study, Software Engineering, Software Quality, Organizational Impact, Usability Requirement Management, CHI 2007 workshop...

  11. Evaluating the Usability of a Controlled Language Authoring Assistant

    Directory of Open Access Journals (Sweden)

    Miyata Rei

    2017-06-01

    Full Text Available This paper presents experimental results of a usability evaluation of a controlled language (CL authoring assistant designed to help non-professional writers create machine translatable source texts. As the author drafts the text, the system detects CL rule violations and proscribed terms. It also incorporates several support functions to facilitate rephrasing of the source. In order to assess the usability of the system, we conducted a rewriting experiment, in which we compared two groups of participants, one with the aid of the system and the other without it. The results revealed that our system helped reduce the number of CL violations by about 9% and the time to correct violations by more than 30%. The CL-applied source text resulted in higher fluency and adequacy of MT outputs. Questionnaire and interview results also implied the improved satisfaction with the task completion of those participants who used the system.

  12. Towards Evidence Based Usability in Health Informatics?

    NARCIS (Netherlands)

    Marcilly, Romaric; Peute, Linda W.; Beuscart-Zephir, Marie-Catherine; Jaspers, Monique W.

    2015-01-01

    In a Health Information Technology (HIT) regulatory context in which the usability of this technology is more and more a critical issue, there is an increasing need for evidence based usability practice. However, a clear definition of evidence based usability practice and how to achieve it is still

  13. Usability and User Experience Information in Reviews

    DEFF Research Database (Denmark)

    Hedegaard, Steffen

    future versions of the prod- uct? The results show that users write about product use in terms related to standard and popularly researched aspects of usability and user experience, e.g. effiiency, effectiveness, enjoyment, frustration. The frequency with which different aspects are depicted in reviews...... differs significantly between product domains. We also find that reviews contain descriptions of more persistent usability issues. I devise automatic methods for classifying sentences with regard to dimensions of both usability and user experience and usability problems and perform a linguistic analysis...

  14. Usability Evaluation in a Digitally Emerging Country

    DEFF Research Database (Denmark)

    Lizano, Fulvio; Sandoval, Maria Marta; Bruun, Anders

    2013-01-01

    Several emerging countries experience increasing software development activities. With the purpose of provide useful feedback on possible courses of action for increasing application of usability evaluation in such countries, this paper explores the status of usability evaluation in a digitally...... emerging country. Our aim is to identifying common characteristics or behavioral patterns that could be compared with digitally advanced countries. We used an online survey answered by 26 software development organizations, which gave a snapshot of the application of usability evaluation...... in these organizations. We found many similarities with advanced countries, several completely new obstacles more connected with software development matters and a relatively positive improvement in the lack of “usability culture”. These findings suggest good conditions to improve conduction of usability evaluations...

  15. Microemulsion Drug Delivery Systems for Radiopharmacy Studies

    Directory of Open Access Journals (Sweden)

    Emre Ozgenc

    2016-11-01

    Full Text Available Microemulsions have been used increasingly for last year’s because of ideal properties like favorable drug delivery, ease of preparation and physical stability. They have been improved the solubility and efficacy of the drug and reduce the side effects. Use of radiolabeled microemulsions plays an alternative role in drug delivery systems by investigating the formation, stability and application of microemulsions in radiopharmacy. Gama scintigraphic method is well recognized for developing and detecting the biodistribution of newly developed drugs or formulation. This review will focus on how radionuclides are able to play role with characterization studies of microemulsion drug delivery systems.

  16. Promise Fulfilled? An EBSCO Discovery Service Usability Study

    Science.gov (United States)

    Williams, Sarah C.; Foster, Anita K.

    2011-01-01

    Discovery tools are the next phase of library search systems. Illinois State University's Milner Library implemented EBSCO Discovery Service in August 2010. The authors conducted usability studies on the system in the fall of 2010. The aims of the study were twofold: first, to determine how Milner users set about using the system in order to…

  17. Web usability evaluation on BloobIS website by using hallway usability testing method and ISO 9241:11

    Science.gov (United States)

    Dwi Susanto, Tony; Ingesti Prasetyo, Anisa; Astuti, Hanim Maria

    2018-03-01

    At this moment, the need for web as an information media is highly important. Not only confined in the infotainment area, government, and education, but health as well uses the web media as a medium for providing information effectively. BloobIS is a web based application which integrates blood supply and distribution information at the Blood Transfusion Unit. Knowing how easy information is on BloobIS is marked by how convenient the website is used. Up until now, the BloobIS website is nearing completion but testing has not yet been performed to users and is on the testing and development phase in the Development Life Cycle software. Thus, an evaluation namely the quality control software which focuses on the perspective of BloobIs web usability is required. Hallway Usability Testing and ISO 9241:11 are the methods chosen to measure the BloobIS application usability. The expected outputs of the quality control software focusing on the usability evaluation are being able to rectify the usability deficiencies on the BloobIs web and provide recommendations to develop the web as a basic BloobIS web quality upgraed which sets a goal to amplify the satisfaction of web users based on usability factors in ISO 9241:11.

  18. Ten factors to consider when developing usability scenarios and tasks for health information technology.

    Science.gov (United States)

    Russ, Alissa L; Saleem, Jason J

    2018-02-01

    The quality of usability testing is highly dependent upon the associated usability scenarios. To promote usability testing as part of electronic health record (EHR) certification, the Office of the National Coordinator (ONC) for Health Information Technology requires that vendors test specific capabilities of EHRs with clinical end-users and report their usability testing process - including the test scenarios used - along with the results. The ONC outlines basic expectations for usability testing, but there is little guidance in usability texts or scientific literature on how to develop usability scenarios for healthcare applications. The objective of this article is to outline key factors to consider when developing usability scenarios and tasks to evaluate computer-interface based health information technologies. To achieve this goal, we draw upon a decade of our experience conducting usability tests with a variety of healthcare applications and a wide range of end-users, to include healthcare professionals as well as patients. We discuss 10 key factors that influence scenario development: objectives of usability testing; roles of end-user(s); target performance goals; evaluation time constraints; clinical focus; fidelity; scenario-related bias and confounders; embedded probes; minimize risks to end-users; and healthcare related outcome measures. For each factor, we present an illustrative example. This article is intended to aid usability researchers and practitioners in their efforts to advance health information technologies. The article provides broad guidance on usability scenario development and can be applied to a wide range of clinical information systems and applications. Published by Elsevier Inc.

  19. A wireless actuating drug delivery system

    International Nuclear Information System (INIS)

    Jo, Won-Jun; Baek, Seung-Ki; Park, Jung-Hwan

    2015-01-01

    A wireless actuating drug delivery system was devised. The system is based on induction heating for drug delivery. In this study, thermally generated nitrogen gas produced by induction heating of azobisisobutyronitrile (AIBN) was utilized for pressure-driven release of the drug. The delivery device consists of an actuator chamber, a drug reservoir, and a microchannel. A semicircular copper disc (5 and 6 mm in diameter and 100 µm thick), and thermal conductive tape were integrated as the heating element in the actuator chamber. The final device was 2.7 mm thick. 28 µl of drug solution were placed in the reservoir and the device released the drug quickly at the rate of 6 µl s −1 by induction heating at 160 µT of magnetic intensity. The entire drug solution was released and dispersed after subcutaneous implantation under identical experimental condition. This study demonstrates that the device was simply prepared and drug delivery could be achieved by wireless actuation of a thin, pressure-driven actuator. (paper)

  20. Log files for testing usability

    NARCIS (Netherlands)

    Klein Teeselink, G.; Siepe, A.H.M.; Pijper, de J.R.

    1999-01-01

    The aim of this study is to gain insight in the usefulness of log file analysis as a method to evaluate the usability of individual interface components and their influence on the usability of the overall user interface. We selected a music player as application, with four different interfaces and

  1. Managing Product Usability : How companies deal with usability in the development of electronic consumer products

    NARCIS (Netherlands)

    Van Kuijk, J.I.

    2010-01-01

    Problem statement: Even though there is a large amount of methods for user-centred design, the usability of electronic consumer products (e.g., portable music players, washing machines and mobile phones) is under pressure. Usability is the extent to which a product can be used by specified users to

  2. Buccal Transmucosal Delivery System of Enalapril for Improved ...

    African Journals Online (AJOL)

    Purpose: To prepare and characterize buccal transmucosal delivery system of enalapril maleate for overcoming its low bioavailability, and hence provide improved therapeutic efficacy and patient compliance. Methods: Transmucosal drug delivery systems of enalapril maleate were formulated as buccal films by solvent ...

  3. Exploring the value of usability feedback formats

    DEFF Research Database (Denmark)

    Nørgaard, Mie; Hornbæk, Kasper Anders Søren

    2009-01-01

    The format used to present feedback from usability evaluations to developers affects whether problems are understood, accepted, and fixed. Yet, little research has investigated which formats are the most effective. We describe an explorative study where three developers assess 40 usability findings...... presented using five feedback formats. Our usability findings comprise 35 problems and 5 positive comments. Data suggest that feedback serves multiple purposes. Initially, feedback must convince developers about the relevance of a problem and convey an understanding of this. Feedback must next be easy...... working with the feedback to address the usability problems, there were no significant differences among the developers' ratings of the value of the different formats. This suggests that all of the formats may serve equally well as reminders in later stages of working with usability problems...

  4. Navigating the high seas of Federal Programs to ensure usable science delivery

    Science.gov (United States)

    Bachelet, D. M.; Gough, M.; Baker, B.; Sheehan, T.; Mutch, T.; Brown, M.

    2016-12-01

    Conservation Biology Institute (CBI) has been developing web applications to serve credible and usable information that allows land stewards, as well as the general public, to better understand the challenges posed by on-going environmental change. Working with 18 Landscape Conservation Cooperatives (LCCs), CBI has developed Conservation Atlases that allow users to visualize regional spatial data. Some include specific tools such as the Conservation Blueprint in the South Atlantic LCC conservation atlas which is a living spatial plan that identifies priority areas for shared conservation action based on ecosystem indicator condition and connectivity. More than 400 people from over 100 different organizations have actively participated in its development so far. CBI worked closely with 4 LCCs to design a Landscape Climate Dashboard (http://bit.ly/2atu8Df) that provides CMIP5 climate projections averaged over federally and tribally protected lands in the western US. With support from BLM and Great Basin LCC, a Sagebrush Climate Console provides managers short-term NOAA forecasts, CMIP5 climate projections, regional intactness and site sensitivity over sagebrush extent and grouse range. The USDA Pacific Northwest Climate Hub and the US Forest Service are currently funding a collaborative effort between CBI programmers, USFS and Oregon State University forest geneticists to develop a seedlot source tool for the conterminous US and Alaska. This tool has inspired Great Basin sagebrush restoration scientists who have collected information on seed provenance and will hopefully soon collaborate to help develop the first seed source tool for sagebrush managers. Furthermore, with support from USDA Northwest Climate Hub, CBI's Data Basin site (http://bit.ly/2aLRlhZ) is providing downscaled CMIP5 climate projections and impacts from a Climate Science Center and NOAA Regional Integrated Science Assessment funded project that was the result of a collaborative effort between

  5. Improving Public Relations Web Sites through Usability Research.

    Science.gov (United States)

    Hallahan, Kirk

    2001-01-01

    Argues that usability research has particular relevance for enhancing the effectiveness of websites. Examines the nature and value of usability research, and the elements of an effective website based on usability principles. (SR)

  6. Oral Drug Delivery Systems Comprising Altered Geometric Configurations for Controlled Drug Delivery

    Directory of Open Access Journals (Sweden)

    Priya Bawa

    2011-12-01

    Full Text Available Recent pharmaceutical research has focused on controlled drug delivery having an advantage over conventional methods. Adequate controlled plasma drug levels, reduced side effects as well as improved patient compliance are some of the benefits that these systems may offer. Controlled delivery systems that can provide zero-order drug delivery have the potential for maximizing efficacy while minimizing dose frequency and toxicity. Thus, zero-order drug release is ideal in a large area of drug delivery which has therefore led to the development of various technologies with such drug release patterns. Systems such as multilayered tablets and other geometrically altered devices have been created to perform this function. One of the principles of multilayered tablets involves creating a constant surface area for release. Polymeric materials play an important role in the functioning of these systems. Technologies developed to date include among others: Geomatrix® multilayered tablets, which utilizes specific polymers that may act as barriers to control drug release; Procise®, which has a core with an aperture that can be modified to achieve various types of drug release; core-in-cup tablets, where the core matrix is coated on one surface while the circumference forms a cup around it; donut-shaped devices, which possess a centrally-placed aperture hole and Dome Matrix® as well as “release modules assemblage”, which can offer alternating drug release patterns. This review discusses the novel altered geometric system technologies that have been developed to provide controlled drug release, also focusing on polymers that have been employed in such developments.

  7. Efficiency performance of China's health care delivery system.

    Science.gov (United States)

    Zhang, Luyu; Cheng, Gang; Song, Suhang; Yuan, Beibei; Zhu, Weiming; He, Li; Ma, Xiaochen; Meng, Qingyue

    2017-07-01

    Improving efficiency performance of the health care delivery system has been on the agenda for the health system reform that China initiated in 2009. This study examines the changes in efficiency performance and determinants of efficiency after the reform to provide evidence to assess the progress of the reform from the perspective of efficiency. Descriptive analysis, Data Envelopment Analysis, the Malmquist Index, and multilevel regressions are used with data from multiple sources, including the World Bank, the China Health Statistical Yearbook, and routine reports. The results indicate that over the last decade, health outcomes compared with health investment were relatively higher in China than in most other countries worldwide, and the trend was stable. The overall efficiency and total factor productivity increased after the reform, indicating that the reform was likely to have had a positive impact on the efficiency performance of the health care delivery system. However, the health care delivery structure showed low system efficiency, mainly attributed to the weakened primary health care system. Strengthening the primary health care system is central to enhancing the future performance of China's health care delivery system. Copyright © 2017 John Wiley & Sons, Ltd.

  8. From Playability to a Hierarchical Game Usability Model

    OpenAIRE

    Nacke, Lennart E.

    2010-01-01

    This paper presents a brief review of current game usability models. This leads to the conception of a high-level game development-centered usability model that integrates current usability approaches in game industry and game research.

  9. Current and emerging lipid-based systems for transdermal drug delivery.

    Science.gov (United States)

    Singla, Sumeet K; Sachdeva, Vishal

    2015-01-01

    Developing a transdermal drug delivery system is a challenging task considering the selective permeability of the skin and the physicochemical properties the drug must possess to permeate through the skin. Lipid-based drug delivery systems have contributed a great deal in this direction in the last few decades, and thereby have helped to expand the range of therapeutic molecules that can be delivered through the skin in a safe and effective manner. Additionally, vesicular delivery systems such as nanoparticles and emulsions have also played important roles in providing alternative novel approaches for drug delivery. In this article, we will discuss some of the current and future lipid-based systems for transdermal drug delivery along with the associated challenges.

  10. Advanced drug delivery systems: Nanotechnology of health design A review

    Directory of Open Access Journals (Sweden)

    Javad Safari

    2014-04-01

    Full Text Available Nanotechnology has finally and firmly entered the realm of drug delivery. Performances of intelligent drug delivery systems are continuously improved with the purpose to maximize therapeutic activity and to minimize undesirable side-effects. This review describes the advanced drug delivery systems based on micelles, polymeric nanoparticles, and dendrimers. Polymeric carbon nanotubes and many others demonstrate a broad variety of useful properties. This review emphasizes the main requirements for developing new nanotech-nology-based drug delivery systems.

  11. A health literacy and usability heuristic evaluation of a mobile consumer health application.

    Science.gov (United States)

    Monkman, Helen; Kushniruk, Andre

    2013-01-01

    Usability and health literacy are two critical factors in the design and evaluation of consumer health information systems. However, methods for evaluating these two factors in conjunction remain limited. This study adapted a set of existing guidelines for the design of consumer health Web sites into evidence-based evaluation heuristics tailored specifically for mobile consumer health applications. In order to test the approach, a mobile consumer health application (app) was then evaluated using these heuristics. In addition to revealing ways to improve the usability of the system, this analysis identified opportunities to augment the content to make it more understandable by users with limited health literacy. This study successfully demonstrated the utility of converting existing design guidelines into heuristics for the evaluation of usability and health literacy. The heuristics generated could be applied for assessing and revising other existing consumer health information systems.

  12. Engineering the system of healthcare delivery

    National Research Council Canada - National Science Library

    Rouse, William B; Cortese, Denis A

    2010-01-01

    "As the United States continues to debate reform of its healthcare system, this book argues that providing health insurance for all without improving the delivery system will not improve the current...

  13. Applications of polymeric nanocapsules in field of drug delivery systems.

    Science.gov (United States)

    Rong, Xinyu; Xie, Yinghua; Hao, Xiaomei; Chen, Tao; Wang, Yingming; Liu, Yuanyuan

    2011-09-01

    Drug-loaded polymeric nanocapsules have exhibited potential applications in the field of drug delivery systems in recent years. This article entails the biodegradable polymers generally used for preparing nanocapsules, which include both natural polymers and synthetic polymers. Furthermore, the article presents a general review of the different preparation methods: nanoprecipitation method, emulsion-diffusion method, double emulsification method, emulsion-coacervation method, layer-by-layer assembly method. In addition, the analysis methods of nanocapsule characteristics, such as mean size, morphology, surface characteristics, shell thickness, encapsulation efficiency, active substance release, dispersion stability, are mentioned. Also, the applications of nanocapsules as carriers for use in drug delivery systems are reviewed, which primarily involve targeting drug delivery, controlled/sustained release drug delivery systems, transdermal drug delivery systems and improving stability and bioavailability of drugs. Nanocapsules, prepared with different biodegradable polymers, have received more and more attention and have been regarded as one of the most promising drug delivery systems.

  14. Usability of PostgreSQL

    OpenAIRE

    Zeng, Xi

    2011-01-01

    My topic of the thesis is usability of PostgreSQL. It presents basic information aboutPostgreSQL, such as its history, function, and comparison with one of the most popular databases - MySQL. PostgreSQL has been tested in different environments and with different programming languages. The research is based on the documents from PostgreSQL official website.The thesis introduces and proves the usability and the compatibility of PostgreSQL. PostgreSQL has been installed on Windows workstation a...

  15. A usability evaluation of a SNOMED CT based compositional interface terminology for intensive care

    NARCIS (Netherlands)

    Bakhshi-Raiez, F.; de Keizer, N. F.; Cornet, R.; Dorrepaal, M.; Dongelmans, D.; Jaspers, M. W. M.

    2012-01-01

    Objective: To evaluate the usability of a large compositional interface terminology based on SNOMED CT and the terminology application for registration of the reasons for intensive care admission in a Patient Data Management System. Design: Observational study with user-based usability evaluations

  16. Usability, acceptability, and adherence to an electronic self-monitoring system in patients with major depression discharged from inpatient wards

    DEFF Research Database (Denmark)

    Lauritsen, Lise; Andersen, Louise; Olsson, Emilia

    2017-01-01

    Background: Patients suffering from depression have a high risk of relapse and readmission in the weeks following discharge from inpatient wards. Electronic self-monitoring systems that offer patient-communication features are now available to offer daily support to patients, but the usability, a...

  17. Active Involvement of Software Developers in Usability Engineering

    DEFF Research Database (Denmark)

    Bornoe, Nis; Stage, Jan

    2017-01-01

    The essence of usability evaluations is to produce feedback that supports the downstream utility so the interaction design can be improved and problems can be fixed. In practice, software development organizations experience several obstacles for conducting usability engineering. One suggested...... approach is to train and involve developers in all phases of usability activities from evaluations, to problem reporting, and making redesign proposals. Only limited work has previously investigated the impact of actively involving developers in usability engineering. In this paper, we present two small......, and problem fixing. At the organizational level, we found that the attitude towards and understanding of the role of usability engineering improved....

  18. Food Delivery System with the Utilization of Vehicle Using Geographical Information System (GIS) and A Star Algorithm

    Science.gov (United States)

    Siregar, B.; Gunawan, D.; Andayani, U.; Sari Lubis, Elita; Fahmi, F.

    2017-01-01

    Food delivery system is one kind of geographical information systems (GIS) that can be applied through digitation process. The main case in food delivery system is the way to determine the shortest path and food delivery vehicle movement tracking. Therefore, to make sure that the digitation process of food delivery system can be applied efficiently, it is needed to add shortest path determination facility and food delivery vehicle tracking. This research uses A Star (A*) algorithm for determining shortest path and location-based system (LBS) programming for moving food delivery vehicle object tracking. According to this research, it is generated the integrated system that can be used by food delivery driver, customer, and administrator in terms of simplifying the food delivery system. Through the application of shortest path and the tracking of moving vehicle, thus the application of food delivery system in the scope of geographical information system (GIS) can be executed.

  19. Usability and accessibility evaluation of the digital doorway

    CSIR Research Space (South Africa)

    Adebesin, TF

    2011-03-01

    Full Text Available The Digital Doorway (DD) is a non-standard computer system deployed to promote computer literacy amongst underprivileged communities in South Africa. Since its inception there has been no usability evaluation of the software installed on the DD...

  20. Usability Testing of a National Substance Use Screening Tool Embedded in Electronic Health Records.

    Science.gov (United States)

    Press, Anne; DeStio, Catherine; McCullagh, Lauren; Kapoor, Sandeep; Morley, Jeanne; Conigliaro, Joseph

    2016-07-08

    Screening, brief intervention, and referral to treatment (SBIRT) is currently being implemented into health systems nationally via paper and electronic methods. The purpose of this study was to evaluate the integration of an electronic SBIRT tool into an existing paper-based SBIRT clinical workflow in a patient-centered medical home. Usability testing was conducted in an academic ambulatory clinic. Two rounds of usability testing were done with medical office assistants (MOAs) using a paper and electronic version of the SBIRT tool, with two and four participants, respectively. Qualitative and quantitative data was analyzed to determine the impact of both tools on clinical workflow. A second round of usability testing was done with the revised electronic version and compared with the first version. Personal workflow barriers cited in the first round of testing were that the electronic health record (EHR) tool was disruptive to patient's visits. In Round 2 of testing, MOAs reported favoring the electronic version due to improved layout and the inclusion of an alert system embedded in the EHR. For example, using the system usability scale (SUS), MOAs reported a grade "1" for the statement, "I would like to use this system frequently" during the first round of testing but a "5" during the second round of analysis. The importance of testing usability of various mediums of tools used in health care screening is highlighted by the findings of this study. In the first round of testing, the electronic tool was reported as less user friendly, being difficult to navigate, and time consuming. Many issues faced in the first generation of the tool were improved in the second generation after usability was evaluated. This study demonstrates how usability testing of an electronic SBRIT tool can help to identify challenges that can impact clinical workflow. However, a limitation of this study was the small sample size of MOAs that participated. The results may have been biased to

  1. Nanotechnology-based drug delivery systems

    Directory of Open Access Journals (Sweden)

    Singh Baljit

    2007-12-01

    Full Text Available Abstract Nanoparticles hold tremendous potential as an effective drug delivery system. In this review we discussed recent developments in nanotechnology for drug delivery. To overcome the problems of gene and drug delivery, nanotechnology has gained interest in recent years. Nanosystems with different compositions and biological properties have been extensively investigated for drug and gene delivery applications. To achieve efficient drug delivery it is important to understand the interactions of nanomaterials with the biological environment, targeting cell-surface receptors, drug release, multiple drug administration, stability of therapeutic agents and molecular mechanisms of cell signalling involved in pathobiology of the disease under consideration. Several anti-cancer drugs including paclitaxel, doxorubicin, 5-fluorouracil and dexamethasone have been successfully formulated using nanomaterials. Quantom dots, chitosan, Polylactic/glycolic acid (PLGA and PLGA-based nanoparticles have also been used for in vitro RNAi delivery. Brain cancer is one of the most difficult malignancies to detect and treat mainly because of the difficulty in getting imaging and therapeutic agents past the blood-brain barrier and into the brain. Anti-cancer drugs such as loperamide and doxorubicin bound to nanomaterials have been shown to cross the intact blood-brain barrier and released at therapeutic concentrations in the brain. The use of nanomaterials including peptide-based nanotubes to target the vascular endothelial growth factor (VEGF receptor and cell adhesion molecules like integrins, cadherins and selectins, is a new approach to control disease progression.

  2. Mapping Disease Data: A Usability Test of an Internet-Based System of Disease Status Disclosure

    Directory of Open Access Journals (Sweden)

    Gareth Enticott

    2018-01-01

    Full Text Available Disease maps are important tools in the management of disease. By communicating risk, disease maps can help raise awareness of disease and encourage farmers and veterinarians to employ best practice to eliminate the spread of disease. However, despite the importance of disease maps in communicating risk and the existence of various online disease maps, there are few studies that explicitly examine their usability. Where disease maps are complicated to use, it seems that they are unlikely to be used effectively. The paper outlines an attempt to create an open access, online, searchable map of incidents of bovine tuberculosis in England and Wales, and analyzes its usability among veterinarians. The paper describes the process of creating the map before describing the results of a series of usability trials. Results show the map to score highly on different measures of usability. However, the trials also revealed a number of social and technical limitations and challenges facing the use of online disease maps, including reputational dangers, role confusion, data accuracy, and data representation. The paper considers the challenges facing disease maps and their potential role in designing new methodologies to evaluate the effectiveness of disease prevention initiatives.

  3. Resistive-wall Wake Effect in the Beam Delivery System

    International Nuclear Information System (INIS)

    Delayen, J.R.; Jefferson Lab; Wu, Juhao; Raubenheimer, T.O.; SLAC; Wang, Jiunn-Ming; BNL, NSLS

    2005-01-01

    General formulae for resistive-wall induced beam dilution are presented and then applied to the final beam delivery system of linear colliders. Criteria for the design of final beam delivery systems are discussed

  4. A Web-Based Graphical Food Frequency Assessment System: Design, Development and Usability Metrics.

    Science.gov (United States)

    Franco, Rodrigo Zenun; Alawadhi, Balqees; Fallaize, Rosalind; Lovegrove, Julie A; Hwang, Faustina

    2017-05-08

    Food frequency questionnaires (FFQs) are well established in the nutrition field, but there remain important questions around how to develop online tools in a way that can facilitate wider uptake. Also, FFQ user acceptance and evaluation have not been investigated extensively. This paper presents a Web-based graphical food frequency assessment system that addresses challenges of reproducibility, scalability, mobile friendliness, security, and usability and also presents the utilization metrics and user feedback from a deployment study. The application design employs a single-page application Web architecture with back-end services (database, authentication, and authorization) provided by Google Firebase's free plan. Its design and responsiveness take advantage of the Bootstrap framework. The FFQ was deployed in Kuwait as part of the EatWellQ8 study during 2016. The EatWellQ8 FFQ contains 146 food items (including drinks). Participants were recruited in Kuwait without financial incentive. Completion time was based on browser timestamps and usability was measured using the System Usability Scale (SUS), scoring between 0 and 100. Products with a SUS higher than 70 are considered to be good. A total of 235 participants created accounts in the system, and 163 completed the FFQ. Of those 163 participants, 142 reported their gender (93 female, 49 male) and 144 reported their date of birth (mean age of 35 years, range from 18-65 years). The mean completion time for all FFQs (n=163), excluding periods of interruption, was 14.2 minutes (95% CI 13.3-15.1 minutes). Female participants (n=93) completed in 14.1 minutes (95% CI 12.9-15.3 minutes) and male participants (n=49) completed in 14.3 minutes (95% CI 12.6-15.9 minutes). Participants using laptops or desktops (n=69) completed the FFQ in an average of 13.9 minutes (95% CI 12.6-15.1 minutes) and participants using smartphones or tablets (n=91) completed in an average of 14.5 minutes (95% CI 13.2-15.8 minutes). The median SUS

  5. Long-term usability

    International Nuclear Information System (INIS)

    Holmgren, M.

    1998-01-01

    Longitudinal studies of the usability of a computer based system for process control has been performed. The whole life-cycle of one system has been of interest, as the problems are varying over time. Repeated measurements of the operators' experiences of this system have been made during 15 years. Of main interest have been the advantages/ disadvantages of computer based system for process control compared with conventional instrumentation. The results showed among other things that (1) computer based systems made it easier to control the process and increased security (2) age differences could be explained by other factors (3 ) expectations before the installation may influence the attitudes and use of equipment for quite some time In some questions the attitudes changed over time while in others they were quite stable, for example, in questions concerning preference for type of equipment. What do operators appreciate in a computer based system for process control? About 300 operators were asked about that. The main factor seems to include a reliable system with valid information that functions during disturbances. Hopefully new systems are designed with that in mind. (author)

  6. Biomimetics in drug delivery systems: A critical review.

    Science.gov (United States)

    Sheikhpour, Mojgan; Barani, Leila; Kasaeian, Alibakhsh

    2017-05-10

    Today, the advanced drug delivery systems have been focused on targeted drug delivery fields. The novel drug delivery is involved with the improvement of the capacity of drug loading in drug carriers, cellular uptake of drug carriers, and the sustained release of drugs within target cells. In this review, six groups of therapeutic drug carriers including biomimetic hydrogels, biomimetic micelles, biomimetic liposomes, biomimetic dendrimers, biomimetic polymeric carriers and biomimetic nanostructures, are studied. The subject takes advantage of the biomimetic methods of productions or the biomimetic techniques for the surface modifications, similar to what accrues in natural cells. Moreover, the effects of these biomimetic approaches for promoting the drug efficiency in targeted drug delivery are visible. The study demonstrates that the fabrication of biomimetic nanocomposite drug carriers could noticeably promote the efficiency of drugs in targeted drug delivery systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. A usability evaluation of the prototype Afrikaanse idiome-woordeboek

    African Journals Online (AJOL)

    When digital tools are developed it is important to consider the usability of the tool. Usability evaluation was done on the Afrikaanse idiome-woordeboek to determine with what success it can be used. Discount usability methods, viz. heuristic evaluation and usability testing were used. This article reports on the findings from ...

  8. Usability Assessment of Text-to-Speech Synthesis for Additional Detail in an Automated Telephone Banking System

    OpenAIRE

    Morton , Hazel; Gunson , Nancie; Marshall , Diarmid; McInnes , Fergus; Ayres , Andrea; Jack , Mervyn

    2010-01-01

    Abstract This paper describes a comprehensive usability evaluation of an automated telephone banking system which employs text-to-speech (TTS) synthesis in offering additional detail on customers? account transactions. The paper describes a series of four experiments in which TTS was employed to offer an extra level of detail to recent transactions listings within an established banking service which otherwise uses recorded speech from a professional recording artist. Results from ...

  9. Usability testing for the rest of us: the application of discount usability principles in the development of an online communications assessment application.

    Science.gov (United States)

    Brock, Douglas; Kim, Sara; Palmer, Odawni; Gallagher, Thomas; Holmboe, Eric

    2013-01-01

    Usability evaluation provides developers and educators with the means to understand user needs, improve overall product utility, and increase user satisfaction. The application of "discount usability" principles developed to make usability testing more practical and useful may improve user experience at minimal cost and require little existing expertise to conduct. We describe an application of discount usability to a high-fidelity online communications assessment application developed by the University of Washington for the American Board of Internal Medicine. Eight internal medicine physicians completed a discount usability test. Sessions were recorded and the videos analyzed for significant usability concerns. Concerns were identified, summarized, discussed, and prioritized by the authors in collaboration with the software developers before implementing any changes to the interface. Thirty-eight significant usability issues were detected and four technical problems were identified. Each issue was responded to through modification of the software, by providing additional instruction, or delayed for a later version to be developed. Discount usability can be easily implemented in academic developmental activities. Our study resulted in the discovery and remediation of significant user problems, in addition to giving important insight into the novel methods built into the application.

  10. Usability Evaluation of www.budget.com

    DEFF Research Database (Denmark)

    Bruun, Anders; Jensen, Janne Jul; Skov, Mikael B.

    This report presents the results of a usability evaluation of the budget.com website. The evaluation was carried out by a team of 4 HCI experts, and it involved 10 potential users. The evaluation is based on measurement of (1) task completion time, (2) task completion, (3) user satisfaction and (4......) perceived workload. We have also analyzed the user interaction with the website for (5) usability problems. Through the evaluation, we have found the following weaknesses of the website:   Reservation takes considerably more time than promised. The website indicates that a reservation can be made in 60...... is not useful for specific purposes. The user satisfaction is generally low. Except one high and two low scores, the user satisfaction was in the middle range. There are too many severe usability problems. The evaluation identified a considerable number of usability problems. 5 of them were critical which means...

  11. Usability Testing: Too Early? Too Much Talking? Too Many Problems?

    DEFF Research Database (Denmark)

    Hertzum, Morten

    2016-01-01

    Usability testing has evolved in response to a search for tests that are cheap, early, easy, and fast. In addition, it accords with a situational definition of usability, such as the one propounded by ISO. By approaching usability from an organizational perspective, this author argues that usabil......Usability testing has evolved in response to a search for tests that are cheap, early, easy, and fast. In addition, it accords with a situational definition of usability, such as the one propounded by ISO. By approaching usability from an organizational perspective, this author argues...... that usability should (also) be evaluated late, that usability professionals should be wary of thinking aloud, and that they should focus more on effects achievement than problem detection....

  12. Iontophoresis: A Potential Emergence of a Transdermal Drug Delivery System

    Science.gov (United States)

    Dhote, Vinod; Bhatnagar, Punit; Mishra, Pradyumna K.; Mahajan, Suresh C.; Mishra, Dinesh K.

    2012-01-01

    The delivery of drugs into systemic circulation via skin has generated much attention during the last decade. Transdermal therapeutic systems propound controlled release of active ingredients through the skin and into the systemic circulation in a predictive manner. Drugs administered through these systems escape first-pass metabolism and maintain a steady state scenario similar to a continuous intravenous infusion for up to several days. However, the excellent impervious nature of the skin offers the greatest challenge for successful delivery of drug molecules by utilizing the concepts of iontophoresis. The present review deals with the principles and the recent innovations in the field of iontophoretic drug delivery system together with factors affecting the system. This delivery system utilizes electric current as a driving force for permeation of ionic and non-ionic medications. The rationale behind using this technique is to reversibly alter the barrier properties of skin, which could possibly improve the penetration of drugs such as proteins, peptides and other macromolecules to increase the systemic delivery of high molecular weight compounds with controlled input kinetics and minimum inter-subject variability. Although iontophoresis seems to be an ideal candidate to overcome the limitations associated with the delivery of ionic drugs, further extrapolation of this technique is imperative for translational utility and mass human application. PMID:22396901

  13. Delivery systems for antimicrobial peptides

    DEFF Research Database (Denmark)

    Nordström, Randi; Malmsten, Martin

    2017-01-01

    Due to rapidly increasing resistance development against conventional antibiotics, finding novel approaches for the treatment of infections has emerged as a key health issue. Antimicrobial peptides (AMPs) have attracted interest in this context, and there is by now a considerable literature...... on the identification such peptides, as well as on their optimization to reach potent antimicrobial and anti-inflammatory effects at simultaneously low toxicity against human cells. In comparison, delivery systems for antimicrobial peptides have attracted considerably less interest. However, such delivery systems...... are likely to play a key role in the development of potent and safe AMP-based therapeutics, e.g., through reducing chemical or biological degradation of AMPs either in the formulation or after administration, by reducing adverse side-effects, by controlling AMP release rate, by promoting biofilm penetration...

  14. [Formulation aspects and ex-vivo examination of buccal drug delivery systems].

    Science.gov (United States)

    Szabó, Barnabás; Hetényi, Gergely; Majoros, Klaudia; Miszori, Veronika; Kállai, Nikolett; Zelkó, Romána

    2011-01-01

    Application of buccal dosage forms has several advantages. Buccal route can be used for systemic delivery because the mucosa has a rich blood supply and it is relatively permeable. This route of drug delivery is of special advantages, including the bypass of first pass effect and the avoidance of presystemic elimination within the GIT. Buccal delivery systems enable the systemic delivery of peptides and proteins. In our previous study the physiological background of this application and the excipients of the possible formulations were reviewed. In the present work the formulation and ex vivo examination aspects of buccal drug delivery systems are summarized.

  15. Usability evaluations in user-centred design

    NARCIS (Netherlands)

    Ruyter, de B.E.R.; Vet, de J.H.M.

    1997-01-01

    Improving usability of consumer applications has been the focus of much research. Estimating the advantage of these efforts, however, still is very cumbersome since evaluating product improvements in terms of their usability requires good measuring methods and tools. In this paper activities in the

  16. A REVIEW ON OSMOTIC DRUG DELIVERY SYSTEM

    OpenAIRE

    Harnish Patel; Upendra Patel; Hiren Kadikar; Bhavin Bhimani; Dhiren Daslaniya; Ghanshyam Patel

    2012-01-01

    Conventional oral drug delivery systems supply an instantaneous release of drug, which cannot control the release of the drug and effective concentration at the target site. This kind of dosing pattern may result in constantly changing, unpredictable plasma concentrations. Drugs can be delivered in a controlled pattern over a long period of time by the process of osmosis. Osmotic devices are the most promising strategy based systems for controlled drug delivery. They are the most reliable con...

  17. Usability Evaluation and Implementation of a Health Information Technology Dashboard of Evidence-Based Quality Indicators.

    Science.gov (United States)

    Schall, Mark Christopher; Cullen, Laura; Pennathur, Priyadarshini; Chen, Howard; Burrell, Keith; Matthews, Grace

    2017-06-01

    Health information technology dashboards that integrate evidence-based quality indicators can efficiently and accurately display patient risk information to promote early intervention and improve overall quality of patient care. We describe the process of developing, evaluating, and implementing a dashboard designed to promote quality care through display of evidence-based quality indicators within an electronic health record. Clinician feedback was sought throughout the process. Usability evaluations were provided by three nurse pairs and one physician from medical-surgical areas. Task completion times, error rates, and ratings of system usability were collected to compare the use of quality indicators displayed on the dashboard to the indicators displayed in a conventional electronic health record across eight experimental scenarios. Participants rated the dashboard as "highly usable" following System Usability Scale (mean, 87.5 [SD, 9.6]) and Poststudy System Usability Questionnaire (mean, 1.7 [SD, 0.5]) criteria. Use of the dashboard led to reduced task completion times and error rates in comparison to the conventional electronic health record for quality indicator-related tasks. Clinician responses to the dashboard display capabilities were positive, and a multifaceted implementation plan has been used. Results suggest application of the dashboard in the care environment may lead to improved patient care.

  18. ReMashed - An Usability Study of a Recommender System for Mash-Ups for Learning

    Directory of Open Access Journals (Sweden)

    Rob Koper

    2010-01-01

    Full Text Available The following article presents an usability study of a Mash-up Personal Learning Environment called ReMashed that recommends items from the emerging information of a Learning Network. In ReMashed users can specify certain Web 2.0 services and combine them in a Mash-Up Personal Learning Environment. The users can rate information from an emerging amount of Web 2.0 information of a Learning Network and train a recommender system for their particular needs. In total 49 participants from 8 different countries registered to evaluate the ReMashed system. The participants contributed Web 2.0 contents and used the recommender system for one month. The evaluation was concluded with an online questionnaire where most of the participants were positive about the ReMashed system and offered helpful ideas for future developments.

  19. Determining Reliability and Validity of the Persian Version of Software Usability Measurements Inventory (SUMI) Questionnaire

    OpenAIRE

    seyed abolfazl zakerian; Roya Azizi; Mehdi Rahgozar

    2013-01-01

    The term usability refers to a special index for success of an operating system. This study aimed to determine the reliability and validity of the Software Usability Measurements Inventory (SUMI) questionnaire as one of the valid and common questionnaires about usability evaluation. The back translation method was used to translate the questionnaire from English to Persian back to English. Moreover, repeatability or test-retest reliability was practically used to determine the reliability of ...

  20. Methods of Usability Testing in Libraries Web Sites

    Directory of Open Access Journals (Sweden)

    Eman Fawzy

    2006-03-01

    Full Text Available A Study about libraries' web sites evaluation, that is the Usability, the study talking about methods of usability testing and define it, and its important in web sites evaluation, then details the methods of usability: questionnaire, core groups, testing experimental model, cards arrangement, and composed evaluation.

  1. Drug delivery systems and materials for wound healing applications.

    Science.gov (United States)

    Saghazadeh, Saghi; Rinoldi, Chiara; Schot, Maik; Kashaf, Sara Saheb; Sharifi, Fatemeh; Jalilian, Elmira; Nuutila, Kristo; Giatsidis, Giorgio; Mostafalu, Pooria; Derakhshandeh, Hossein; Yue, Kan; Swieszkowski, Wojciech; Memic, Adnan; Tamayol, Ali; Khademhosseini, Ali

    2018-04-05

    Chronic, non-healing wounds place a significant burden on patients and healthcare systems, resulting in impaired mobility, limb amputation, or even death. Chronic wounds result from a disruption in the highly orchestrated cascade of events involved in wound closure. Significant advances in our understanding of the pathophysiology of chronic wounds have resulted in the development of drugs designed to target different aspects of the impaired processes. However, the hostility of the wound environment rich in degradative enzymes and its elevated pH, combined with differences in the time scales of different physiological processes involved in tissue regeneration require the use of effective drug delivery systems. In this review, we will first discuss the pathophysiology of chronic wounds and then the materials used for engineering drug delivery systems. Different passive and active drug delivery systems used in wound care will be reviewed. In addition, the architecture of the delivery platform and its ability to modulate drug delivery are discussed. Emerging technologies and the opportunities for engineering more effective wound care devices are also highlighted. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Improvement of different vaccine delivery systems for cancer therapy

    Directory of Open Access Journals (Sweden)

    Safaiyan Shima

    2011-01-01

    Full Text Available Abstract Cancer vaccines are the promising tools in the hands of the clinical oncologist. Many tumor-associated antigens are excellent targets for immune therapy and vaccine design. Optimally designed cancer vaccines should combine the best tumor antigens with the most effective immunotherapy agents and/or delivery strategies to achieve positive clinical results. Various vaccine delivery systems such as different routes of immunization and physical/chemical delivery methods have been used in cancer therapy with the goal to induce immunity against tumor-associated antigens. Two basic delivery approaches including physical delivery to achieve higher levels of antigen production and formulation with microparticles to target antigen-presenting cells (APCs have demonstrated to be effective in animal models. New developments in vaccine delivery systems will improve the efficiency of clinical trials in the near future. Among them, nanoparticles (NPs such as dendrimers, polymeric NPs, metallic NPs, magnetic NPs and quantum dots have emerged as effective vaccine adjuvants for infectious diseases and cancer therapy. Furthermore, cell-penetrating peptides (CPP have been known as attractive carrier having applications in drug delivery, gene transfer and DNA vaccination. This review will focus on the utilization of different vaccine delivery systems for prevention or treatment of cancer. We will discuss their clinical applications and the future prospects for cancer vaccine development.

  3. A comparison of usability methods for testing interactive health technologies: methodological aspects and empirical evidence.

    Science.gov (United States)

    Jaspers, Monique W M

    2009-05-01

    Usability evaluation is now widely recognized as critical to the success of interactive health care applications. However, the broad range of usability inspection and testing methods available may make it difficult to decide on a usability assessment plan. To guide novices in the human-computer interaction field, we provide an overview of the methodological and empirical research available on the three usability inspection and testing methods most often used. We describe two 'expert-based' and one 'user-based' usability method: (1) the heuristic evaluation, (2) the cognitive walkthrough, and (3) the think aloud. All three usability evaluation methods are applied in laboratory settings. Heuristic evaluation is a relatively efficient usability evaluation method with a high benefit-cost ratio, but requires high skills and usability experience of the evaluators to produce reliable results. The cognitive walkthrough is a more structured approach than the heuristic evaluation with a stronger focus on the learnability of a computer application. Major drawbacks of the cognitive walkthrough are the required level of detail of task and user background descriptions for an adequate application of the latest version of the technique. The think aloud is a very direct method to gain deep insight in the problems end users encounter in interaction with a system but data analyses is extensive and requires a high level of expertise both in the cognitive ergonomics and in computer system application domain. Each of the three usability evaluation methods has shown its usefulness, has its own advantages and disadvantages; no single method has revealed any significant results indicating that it is singularly effective in all circumstances. A combination of different techniques that compliment one another should preferably be used as their collective application will be more powerful than applied in isolation. Innovative mobile and automated solutions to support end-user testing have

  4. Interplay between usability evaluation and software development (I-USED 2009)

    DEFF Research Database (Denmark)

    Abrahão, S.; Hornbæk, Kasper Anders Søren; Law, E.

    2009-01-01

    This workshop is aimed at bringing together researchers and practitioners from the Human-Computer Interaction (HCI) and Software Engineering (SE) fields to determine the state-of-the-art in the interplay between usability evaluation and software development and to generate ideas for new...... and improved relations between these activities. The aim is to base the determination of the current state on empirical studies. Presentations of new ideas on how to improve the interplay between HCI & SE to the design of usable software systems should also be based on empirical studies....

  5. Reusable Software Usability Specifications for mHealth Applications.

    Science.gov (United States)

    Cruz Zapata, Belén; Fernández-Alemán, José Luis; Toval, Ambrosio; Idri, Ali

    2018-01-25

    One of the key factors for the adoption of mobile technologies, and in particular of mobile health applications, is usability. A usable application will be easier to use and understand by users, and will improve user's interaction with it. This paper proposes a software requirements catalog for usable mobile health applications, which can be used for the development of new applications, or the evaluation of existing ones. The catalog is based on the main identified sources in literature on usability and mobile health applications. Our catalog was organized according to the ISO/IEC/IEEE 29148:2011 standard and follows the SIREN methodology to create reusable catalogs. The applicability of the catalog was verified by the creation of an audit method, which was used to perform the evaluation of a real app, S Health, application created by Samsung Electronics Co. The usability requirements catalog, along with the audit method, identified several usability flaws on the evaluated app, which scored 83%. Some flaws were detected in the app related to the navigation pattern. Some more issues related to the startup experience, empty screens or writing style were also found. The way a user navigates through an application improves or deteriorates user's experience with the application. We proposed a reusable usability catalog and an audit method. This proposal was used to evaluate a mobile health application. An audit report was created with the usability issues identified on the evaluated application.

  6. Oral controlled release drug delivery system and Characterization of oral tablets; A review

    Directory of Open Access Journals (Sweden)

    Muhammad Zaman

    2016-01-01

    Full Text Available Oral route of drug administration is considered as the safest and easiest route of drug administration. Control release drug delivery system is the emerging trend in the pharmaceuticals and the oral route is most suitable for such kind of drug delivery system. Oral route is more convenient for It all age group including both pediatric and geriatrics. There are various systems which are adopted to deliver drug in a controlled manner to different target sites through oral route. It includes diffusion controlled drug delivery systems; dissolution controlled drug delivery systems, osmotically controlled drug delivery systems, ion-exchange controlled drug delivery systems, hydrodynamically balanced systems, multi-Particulate drug delivery systems and microencapsulated drug delivery system. The systems are formulated using different natural, semi-synthetic and synthetic polymers. The purpose of the review is to provide information about the orally controlled drug delivery system, polymers which are used to formulate these systems and characterizations of one of the most convenient dosage form which is the tablets. 

  7. Broadly Applicable Nanowafer Drug Delivery System for Treating Eye Injuries

    Science.gov (United States)

    2015-09-01

    Systems in Systemic , Dermal, Transdermal , and Ocular Drug Delivery . Crit. Rev. Ther. Drug 2008, 25, 545–584. 14. Choy, Y. B.; Park, J.-H.; McCarey, B...AWARD NUMBER: W81XWH-13-1-0146 TITLE: Broadly Applicable Nanowafer Drug Delivery System for Treating Eye Injuries PRINCIPAL INVESTIGATOR: Dr...Broadly Applicable Nanowafer Drug Delivery System for Treating Eye Injuries” 5b. GRANT NUMBER W81XWH-13-1-0146 5c. PROGRAM ELEMENT NUMBER 6

  8. Chitosan microspheres in novel drug delivery systems.

    Science.gov (United States)

    Mitra, Analava; Dey, Baishakhi

    2011-07-01

    The main aim in the drug therapy of any disease is to attain the desired therapeutic concentration of the drug in plasma or at the site of action and maintain it for the entire duration of treatment. A drug on being used in conventional dosage forms leads to unavoidable fluctuations in the drug concentration leading to under medication or overmedication and increased frequency of dose administration as well as poor patient compliance. To minimize drug degradation and loss, to prevent harmful side effects and to increase drug bioavailability various drug delivery and drug targeting systems are currently under development. Handling the treatment of severe disease conditions has necessitated the development of innovative ideas to modify drug delivery techniques. Drug targeting means delivery of the drug-loaded system to the site of interest. Drug carrier systems include polymers, micelles, microcapsules, liposomes and lipoproteins to name some. Different polymer carriers exert different effects on drug delivery. Synthetic polymers are usually non-biocompatible, non-biodegradable and expensive. Natural polymers such as chitin and chitosan are devoid of such problems. Chitosan comes from the deacetylation of chitin, a natural biopolymer originating from crustacean shells. Chitosan is a biocompatible, biodegradable, and nontoxic natural polymer with excellent film-forming ability. Being of cationic character, chitosan is able to react with polyanions giving rise to polyelectrolyte complexes. Hence chitosan has become a promising natural polymer for the preparation of microspheres/nanospheres and microcapsules. The techniques employed to microencapsulate with chitosan include ionotropic gelation, spray drying, emulsion phase separation, simple and complex coacervation. This review focuses on the preparation, characterization of chitosan microspheres and their role in novel drug delivery systems.

  9. Renewable energy delivery systems and methods

    Science.gov (United States)

    Walker, Howard Andrew

    2013-12-10

    A system, method and/or apparatus for the delivery of energy at a site, at least a portion of the energy being delivered by at least one or more of a plurality of renewable energy technologies, the system and method including calculating the load required by the site for the period; calculating the amount of renewable energy for the period, including obtaining a capacity and a percentage of the period for the renewable energy to be delivered; comparing the total load to the renewable energy available; and, implementing one or both of additional and alternative renewable energy sources for delivery of energy to the site.

  10. Injectable In-Situ Gelling Controlled Release Drug Delivery System

    OpenAIRE

    Kulwant Singh; S. L. HariKumar

    2012-01-01

    The administration of poorly bioavailable drug through parenteral route is regarded the most efficient for drug delivery. Parenteral delivery provides rapid onset even for the drug with narrow therapeutic window, but to maintain the systemic drug level repeated installation are required which cause the patient discomfort. This can be overcome by designing the drug into a system, which control the drug release even through parenteral delivery, which improve patient compliance as well as pharma...

  11. A continuous usability evaluation of an electronic medication administration record application.

    Science.gov (United States)

    Vicente Oliveros, Noelia; Gramage Caro, Teresa; Pérez Menéndez-Conde, Covadonga; Álvarez-Diaz, Ana María; Martín-Aragón Álvarez, Sagrario; Bermejo Vicedo, Teresa; Delgado Silveira, Eva

    2017-12-01

    The complexity of an electronic medication administration record (eMAR) has been underestimated by most designers in the past. Usability issues, such as poorly designed user application flow in eMAR, are therefore of vital importance, since they can have a negative impact on nursing activities and result in poor outcomes. The purpose of this study was to evaluate the usability of an eMAR application during its development. A usability evaluation was conducted during the development of the eMAR application. Two usability methods were used: a heuristic evaluation complemented by usability testing. Each eMAR application version provided by the vendor was evaluated by 2 hospital pharmacists, who applied the heuristic method. They reviewed the eMAR tasks, detected usability problems and their heuristic violations, and rated the severity of the usability problems. Usability testing was used to assess the final application version by observing how 3 nurses interacted with the application. Thirty-four versions were assessed before the eMAR application was considered usable. During the heuristic evaluation, the usability problems decreased from 46 unique usability problems in version 1 (V1) to 9 in version 34 (V34). In V1, usability problems were categorized into 154 heuristic violations, which decreased to 27 in V34. The average severity rating also decreased from major usability problem (2.96) to no problem (0.23). During usability testing, the 3 nurses did not encounter new usability problems. A thorough heuristic evaluation is a good method for obtaining a usable eMAR application. This evaluation points key areas for improvement and decreases usability problems and their severity. © 2017 John Wiley & Sons, Ltd.

  12. Handheld Delivery System for Modified Boron-Type Fire Extinguishment Agent

    Science.gov (United States)

    1993-11-01

    was to develop and test a handheld portable delivery system for use with the modified boron-type fire extinguishing agent for metal fires . B...BACKGROUND A need exists for an extinguishing agent and accompanying delivery system that are effective against complex geometry metal fires . A modified...agent and its delivery system have proven effective against complex geometry metal fires containing up to 200 pounds of magnesium metal. Further

  13. Usability Assessment of the Missouri Cancer Registry’s Published Interactive Mapping Reports: Round One

    Science.gov (United States)

    Jackson-Thompson, Jeannette; Schmaltz, Chester Lee

    2017-01-01

    Background  Many users of spatial data have difficulty interpreting information in health-related spatial reports. The Missouri Cancer Registry and Research Center (MCR-ARC) has produced interactive reports for several years. These reports have never been tested for usability. Objective  The aims of this study were to: (1) conduct a multi-approach usability testing study to understand ease of use (user friendliness) and user satisfaction; and (2) evaluate the usability of MCR-ARC’s published InstantAtlas reports. Methods   An institutional review board (IRB) approved mixed methodology usability testing study using a convenience sample of health professionals. A recruiting email was sent to faculty in the Master of Public Health program and to faculty and staff in the Department of Health Management and Informatics at the University of Missouri-Columbia. The study included 7 participants. The test included a pretest questionnaire, a multi-task usability test, and the System Usability Scale (SUS). Also, the researchers collected participants’ comments about the tested maps immediately after every trial. Software was used to record the computer screen during the trial and the participants’ spoken comments. Several performance and usability metrics were measured to evaluate the usability of MCR-ARC’s published mapping reports. Results Of the 10 assigned tasks, 6 reached a 100% completion success rate, and this outcome was relative to the complexity of the tasks. The simple tasks were handled more efficiently than the complicated tasks. The SUS score ranged between 20-100 points, with an average of 62.7 points and a median of 50.5 points. The tested maps’ effectiveness outcomes were better than the efficiency and satisfaction outcomes. There was a statistically significant relationship between the subjects’ performance on the study test and the users’ previous experience with geographic information system (GIS) tools (P=.03). There were no

  14. Usability and Gratifications--Towards a Website Analysis Model.

    Science.gov (United States)

    Bunz, Ulla K.

    This paper discusses Web site usability issues. Specifically, it assumes that the usability of a Web site depends more on the perception of the user than on the objectively assessable usability criteria of the Web site. Two pilot studies, based on theoretical notions of uses and gratifications theory and similar theories, are presented. In the…

  15. Mobile Usability Testing in Healthcare: Methodological Approaches.

    Science.gov (United States)

    Borycki, Elizabeth M; Monkman, Helen; Griffith, Janessa; Kushniruk, Andre W

    2015-01-01

    The use of mobile devices and healthcare applications is increasing exponentially worldwide. This has lead to the need for the healthcare industry to develop a better understanding of the impact of the usability of mobile software and hardware upon consumer and health professional adoption and use of these technologies. There are many methodological approaches that can be employed in conducting usability evaluation of mobile technologies. More obtrusive approaches to collecting study data may lead to changes in study participant behaviour, leading to study results that are less consistent with how the technologies will be used in the real-world. Alternatively, less obstrusive methods used in evaluating the usability of mobile software and hardware in-situ and laboratory settings can lead to less detailed information being collected about how an individual interacts with both the software and hardware. In this paper we review and discuss several innovative mobile usability evaluation methods on a contiuum from least to most obtrusive and their effects on the quality of the usability data collected. The strengths and limitations of methods are also discussed.

  16. Evaluation Methods on Usability of M-Learning Environments

    Directory of Open Access Journals (Sweden)

    Teresa Magal-Royo

    2007-10-01

    Full Text Available Nowadays there are different evaluation methods focused in the assessment of the usability of telematic methods. The assessment of 3rd generation web environments evaluates the effectiveness and usability of application with regard to the user needs. Wireless usability and, specifically in mobile phones, is concentrated in the validation of the features and tools management using conventional interactive environments. There is not a specific and suitable criterion to evaluate created environments and m-learning platforms, where the restricted and sequential representation is a fundamental aspect to be considered.The present paper exposes the importance of the conventional usability methods to verify both: the employed contents in wireless formats, and the possible interfaces from the conception phases, to the validations of the platform with such characteristics.The development of usability adapted inspection could be complemented with the Remote’s techniques of usability testing, which are being carried out these days in the mobile devices field and which pointed out the need to apply common criteria in the validation of non-located learning scenarios.

  17. Usability evaluation of mobile applications using ISO 9241 and ISO 25062 standards.

    Science.gov (United States)

    Moumane, Karima; Idri, Ali; Abran, Alain

    2016-01-01

    This paper presents an empirical study based on a set of measures to evaluate the usability of mobile applications running on different mobile operating systems, including Android, iOS and Symbian. The aim is to evaluate empirically a framework that we have developed on the use of the Software Quality Standard ISO 9126 in mobile environments, especially the usability characteristic. To do that, 32 users had participated in the experiment and we have used ISO 25062 and ISO 9241 standards for objective measures by working with two widely used mobile applications: Google Apps and Google Maps. The QUIS 7.0 questionnaire have been used to collect measures assessing the users' level of satisfaction when using these two mobile applications. By analyzing the results we highlighted a set of mobile usability issues that are related to the hardware as well as to the software and that need to be taken into account by designers and developers in order to improve the usability of mobile applications.

  18. Characterization of particulate drug delivery systems for oral delivery of Peptide and protein drugs

    DEFF Research Database (Denmark)

    Christophersen, Philip Carsten; Fano, Mathias; Saaby, Lasse

    2015-01-01

    Oral drug delivery is a preferred route because of good patient compliance. However, most peptide/ protein drugs are delivered via parenteral routes because of the absorption barriers in the gastrointestinal (GI) tract such as enzymatic degradation by proteases and low permeability acrossthe...... delivery of peptide/protein drugs and to provide an overview of formulationand characterization strategies. For a better understanding of the challenges in oral delivery of peptide/protein drugs, the composition of GI fluids and the digestion processes of different kinds of excipients in the GI tract...... biological membranes. To overcome these barriers, different formulation strategies for oral delivery of biomacromolecules have been proposed, including lipid based formulations and polymer-based particulate drug delivery systems (DDS). The aim of this review is to summarize the existing knowledge about oral...

  19. Controlled drug delivery systems towards new frontiers in patient care

    CERN Document Server

    Rossi, Filippo; Masi, Maurizio

    2016-01-01

    This book offers a state-of-the-art overview of controlled drug delivery systems, covering the most important innovative applications. The principles of controlled drug release and the mechanisms involved in controlled release are clearly explained. The various existing polymeric drug delivery systems are reviewed, and new frontiers in material design are examined in detail, covering a wide range of polymer modification techniques. The concluding chapter is a case study focusing on use of a drug-eluting stent. The book is designed to provide the reader with a complete understanding of the mechanisms and design of controlled drug delivery systems, and to this end includes numerous step-by-step tutorials. It illustrates how chemical engineers can advance medical care by designing polymeric delivery systems that achieve either temporal or spatial control of drug delivery and thus ensure more effective therapy that eliminates the potential for both under-and overdosing.

  20. Printing technologies in fabrication of drug delivery systems.

    Science.gov (United States)

    Kolakovic, Ruzica; Viitala, Tapani; Ihalainen, Petri; Genina, Natalja; Peltonen, Jouko; Sandler, Niklas

    2013-12-01

    There has been increased activity in the field recently regarding the development and research on various printing techniques in fabrication of dosage forms and drug delivery systems. These technologies may offer benefits and flexibility in manufacturing, potentially paving the way for personalized dosing and tailor-made dosage forms. In this review, the most recent observations and advancements in fabrication of drug delivery systems by utilizing printing technologies are summarized. A general overview of 2D printing techniques is presented including a review of the most recent literature where printing techniques are used in fabrication of drug delivery systems. The future perspectives and possible impacts on formulation strategies, flexible dosing and personalized medication of using printing techniques for fabrication of drug delivery systems are discussed. It is evident that there is an urgent need to meet the challenges of rapidly growing trend of personalization of medicines through development of flexible drug-manufacturing approaches. In this context, various printing technologies, such as inkjet and flexography, can play an important role. Challenges on different levels exist and include: i) technological development of printers and production lines; ii) printable formulations and carrier substrates; iii) quality control and characterization; and iv) regulatory perspectives.

  1. Model for determining and optimizing delivery performance in industrial systems

    Directory of Open Access Journals (Sweden)

    Fechete Flavia

    2017-01-01

    Full Text Available Performance means achieving organizational objectives regardless of their nature and variety, and even overcoming them. Improving performance is one of the major goals of any company. Achieving the global performance means not only obtaining the economic performance, it is a must to take into account other functions like: function of quality, delivery, costs and even the employees satisfaction. This paper aims to improve the delivery performance of an industrial system due to their very low results. The delivery performance took into account all categories of performance indicators, such as on time delivery, backlog efficiency or transport efficiency. The research was focused on optimizing the delivery performance of the industrial system, using linear programming. Modeling the delivery function using linear programming led to obtaining precise quantities to be produced and delivered each month by the industrial system in order to minimize their transport cost, satisfying their customers orders and to control their stock. The optimization led to a substantial improvement in all four performance indicators that concern deliveries.

  2. Servir: an automated document delivery system

    International Nuclear Information System (INIS)

    Lima, E.C.; Azevedo Coutinho, O.C. de

    1986-01-01

    SERVIR, an automated document delivery system developed by CIN/CNEN, is described. Parametric procedures for reading bibliographic data bases and requesting documents from libraries through computer are specified. Statistical procedures, accounting system and the on-line fulfillment of requests are presented. (Author) [pt

  3. The usability of ventilators: a comparative evaluation of use safety and user experience.

    Science.gov (United States)

    Morita, Plinio P; Weinstein, Peter B; Flewwelling, Christopher J; Bañez, Carleene A; Chiu, Tabitha A; Iannuzzi, Mario; Patel, Aastha H; Shier, Ashleigh P; Cafazzo, Joseph A

    2016-08-20

    The design complexity of critical care ventilators (CCVs) can lead to use errors and patient harm. In this study, we present the results of a comparison of four CCVs from market leaders, using a rigorous methodology for the evaluation of use safety and user experience of medical devices. We carried out a comparative usability study of four CCVs: Hamilton G5, Puritan Bennett 980, Maquet SERVO-U, and Dräger Evita V500. Forty-eight critical care respiratory therapists participated in this fully counterbalanced, repeated measures study. Participants completed seven clinical scenarios composed of 16 tasks on each ventilator. Use safety was measured by percentage of tasks with use errors or close calls (UE/CCs). User experience was measured by system usability and workload metrics, using the Post-Study System Usability Questionnaire (PSSUQ) and the National Aeronautics and Space Administration Task Load Index (NASA-TLX). Nine of 18 post hoc contrasts between pairs of ventilators were significant after Bonferroni correction, with effect sizes between 0.4 and 1.09 (Cohen's d). There were significantly fewer UE/CCs with SERVO-U when compared to G5 (p = 0.044) and V500 (p = 0.020). Participants reported higher system usability for G5 when compared to PB980 (p = 0.035) and higher system usability for SERVO-U when compared to G5 (p ventilators from market leaders compare and highlights the importance of medical technology design. Within the boundaries of this study, we can infer that SERVO-U demonstrated the highest levels of use safety and user experience, followed by G5. Based on qualitative data, differences in outcomes could be explained by interaction design, quality of hardware components used in manufacturing, and influence of consumer product technology on users' expectations.

  4. The effect of touch-key size on the usability of In-Vehicle Information Systems and driving safety during simulated driving.

    Science.gov (United States)

    Kim, Heejin; Kwon, Sunghyuk; Heo, Jiyoon; Lee, Hojin; Chung, Min K

    2014-05-01

    Investigating the effect of touch-key size on usability of In-Vehicle Information Systems (IVISs) is one of the most important research issues since it is closely related to safety issues besides its usability. This study investigated the effects of the touch-key size of IVISs with respect to safety issues (the standard deviation of lane position, the speed variation, the total glance time, the mean glance time, the mean time between glances, and the mean number of glances) and the usability of IVISs (the task completion time, error rate, subjective preference, and NASA-TLX) through a driving simulation. A total of 30 drivers participated in the task of entering 5-digit numbers with various touch-key sizes while performing simulated driving. The size of the touch-key was 7.5 mm, 12.5 mm, 17.5 mm, 22.5 mm and 27.5 mm, and the speed of driving was set to 0 km/h (stationary state), 50 km/h and 100 km/h. As a result, both the driving safety and the usability of the IVISs increased as the touch-key size increased up to a certain size (17.5 mm in this study), at which they reached asymptotes. We performed Fitts' law analysis of our data, and this revealed that the data from the dual task experiment did not follow Fitts' law. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  5. Recent trends in drug delivery system using protein nanoparticles.

    Science.gov (United States)

    Sripriyalakshmi, S; Jose, Pinkybel; Ravindran, Aswathy; Anjali, C H

    2014-09-01

    Engineered nanoparticles that can facilitate drug formulation and passively target tumours have been under extensive research in recent years. These successes have driven a new wave of significant innovation in the generation of advanced particles. The fate and transport of diagnostic nanoparticles would significantly depend on nonselective drug delivery, and hence the use of high drug dosage is implemented. In this perspective, nanocarrier-based drug targeting strategies can be used which improve the selective delivery of drugs to the site of action, i.e. drug targeting. Pharmaceutical industries majorly focus on reducing the toxicity and side effects of drugs but only recently it has been realised that carrier systems themselves may pose risks to the patient. Proteins are compatible with biological systems and they are biodegradable. They offer a multitude of moieties for modifications to tailor drug binding, imaging or targeting entities. Thus, protein nanoparticles provide outstanding contributions as a carrier for drug delivery systems. This review summarises recent progress in particle-based therapeutic delivery and discusses important concepts in particle design and biological barriers for developing the next generation of particles drug delivery systems.

  6. Meta-Analysis of Correlations Among Usability Measures

    DEFF Research Database (Denmark)

    Hornbæk, Kasper Anders Søren; Effie Lai Chong, Law

    2007-01-01

    are generally low: effectiveness measures (e.g., errors) and efficiency measures (e.g., time) has a correlation of .247 ± .059 (Pearson's product-moment correlation with 95% confidence interval), efficiency and satisfaction (e.g., preference) one of .196 ± .064, and effectiveness and satisfaction one of .164......Understanding the relation between usability measures seems crucial to deepen our conception of usability and to select the right measures for usability studies. We present a meta-analysis of correlations among usability measures calculated from the raw data of 73 studies. Correlations...... ± .062. Changes in task complexity do not influence these correlations, but use of more complex measures attenuates them. Standard questionnaires for measuring satisfaction appear more reliable than homegrown ones. Measures of users' perceptions of phenomena are generally not correlated with objective...

  7. Grizzli mobile systems and LPG delivery management; Grizzli mobile systems

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2000-07-01

    Complete text of publication follows: Grizzli Mobile Systems (and its sister companies) specialists in data communications and system solutions, offer their complete management solution for LPG deliveries, right through from remote reading of the gas level in the tank, through route management, management of the delivery itself and finally on-site invoicing and payment. The system permits a supplier to really differentiate itself from its competitors in terms of customer service and control of its operations. Domestic gas tanks are often difficult to access; visual reading of the gauge is not always easy and often leads to the customer re-ordering in panic mode. The supplier has also to react in panic mode to the customer. Grizzli Mobile Systems has developed a radio module that is fitted to the gas tank that calls, at regular set intervals with the tank level to a Call Rider gateway plug. The Call Rider is a small box plugged into the regular telephone socket (also supplying multiple operator telephony and other home automation services). As soon as the gas level reaches a predetermined minimum level, this radio information is relayed via the Internet to the LPG supplier. The supplier can then arrange (in non-panic mode) to deliver gas to the customer, via conventional means or by use of an interactive radio display (attached to a refrigerator or similar by magnets) that communicates with the Call Rider by radio. Once a delivery date has been set, a Grizzli Mobile Systems' dispatch system, installed at the supplier's headquarters creates and transfers routes via GSM communications to its fleet of delivery vehicles. A main-frame mapping software provides real-time follow-up and status checks of the vehicles using the GPS functionality and imports data back from the vehicles and updates databases. The driver is also assisted in localizing delivery sites. Inside the cabin of the vehicle the driver has available a Fujitsu PenCentra pen computer, a Microsoft

  8. A Novel Nonviral Gene Delivery System: Multifunctional Envelope-Type Nano Device

    Science.gov (United States)

    Hatakeyama, Hiroto; Akita, Hidetaka; Kogure, Kentaro; Harashima, Hideyoshi

    In this review we introduce a new concept for developing a nonviral gene delivery system which we call "Programmed Packaging." Based on this concept, we succeeded in developing a multifunctional envelope-type nano device (MEND), which exerts high transfection activities equivalent to those of an adenovirus in a dividing cell. The use of MEND has been extended to in vivo applications. PEG/peptide/DOPE ternary conjugate (PPD)-MEND, a new in vivo gene delivery system for the targeting of tumor cells that dissociates surface-modified PEG in tumor tissue by matrix metalloproteinase (MMP) and exerts significant transfection activities, was developed. In parallel with the development of MEND, a quantitative gene delivery system, Confocal Image-assisted 3-dimensionally integrated quantification (CIDIQ), also was developed. This method identified the rate-limiting step of the nonviral gene delivery system by comparing it with adenoviral-mediated gene delivery. The results of this analysis provide a new direction for the development of rational nonviral gene delivery systems.

  9. Guidelines for Psychological Practice in Health Care Delivery Systems

    Science.gov (United States)

    American Psychologist, 2013

    2013-01-01

    Psychologists practice in an increasingly diverse range of health care delivery systems. The following guidelines are intended to assist psychologists, other health care providers, administrators in health care delivery systems, and the public to conceptualize the roles and responsibilities of psychologists in these diverse contexts. These…

  10. A mucoadhesive in situ gel delivery system for paclitaxel

    OpenAIRE

    Jauhari, Saurabh; Dash, Alekha K.

    2006-01-01

    MUC1 gene encodes a transmembrane mucin glycoprotein that is overexpressed in human breast cancer and colon cancer. The objective of this study was to develop an in situ gel delivery system containing paclitaxel (PTX) and mucoadhesives for sustained and targeted delivery of anticancer drugs. The delivery system consisted of chitosan and glyceryl monooleate (GMO) in 0.33M citric acid containing PTX. The in vitro release of PTX from the gel was performed in presence and absence of Tween 80 at d...

  11. Interpenetrating Polymer Networks as Innovative Drug Delivery Systems

    Directory of Open Access Journals (Sweden)

    Alka Lohani

    2014-01-01

    Full Text Available Polymers have always been valuable excipients in conventional dosage forms, also have shown excellent performance into the parenteral arena, and are now capable of offering advanced and sophisticated functions such as controlled drug release and drug targeting. Advances in polymer science have led to the development of several novel drug delivery systems. Interpenetrating polymer networks (IPNs have shown superior performances over the conventional individual polymers and, consequently, the ranges of applications have grown rapidly for such class of materials. The advanced properties of IPNs like swelling capacity, stability, biocompatibility, nontoxicity and biodegradability have attracted considerable attention in pharmaceutical field especially in delivering bioactive molecules to the target site. In the past few years various research reports on the IPN based delivery systems showed that these carriers have emerged as a novel carrier in controlled drug delivery. The present review encompasses IPNs, their types, method of synthesis, factors which affects the morphology of IPNs, extensively studied IPN based drug delivery systems, and some natural polymers widely used for IPNs.

  12. Biomaterial-based drug delivery systems for the controlled release of neurotrophic factors

    International Nuclear Information System (INIS)

    Mohtaram, Nima Khadem; Montgomery, Amy; Willerth, Stephanie M

    2013-01-01

    This review highlights recent work on the use of biomaterial-based drug delivery systems to control the release of neurotrophic factors as a potential strategy for the treatment of neurological disorders. Examples of neurotrophic factors include the nerve growth factor, the glial cell line-derived neurotrophic factor, the brain-derived neurotrophic factor and neurotrophin-3. In particular, this review focuses on two methods of drug delivery: affinity-based and reservoir-based systems. We review the advantages and challenges associated with both types of drug delivery system and how these systems can be applied to neurological diseases and disorders. While a limited number of affinity-based delivery systems have been developed for the delivery of neurotrophic factors, we also examine the broad spectrum of reservoir-based delivery systems, including microspheres, electrospun nanofibers, hydrogels and combinations of these systems. Finally, conclusions are drawn about the current state of such drug delivery systems as applied to neural tissue engineering along with some thoughts on the future direction of the field. (topical review)

  13. Usability evaluation techniques in mobile commerce applications: A systematic review

    Science.gov (United States)

    Hussain, Azham; Mkpojiogu, Emmanuel O. C.

    2016-08-01

    Obviously, there are a number of literatures concerning the usability of mobile commerce (m-commerce) applications and related areas, but they do not adequately provide knowledge about usability techniques used in most of the empirical usability evaluation for m-commerce application. Therefore, this paper is aimed at producing the usability techniques frequently used in the aspect of usability evaluation for m-commerce applications. To achieve the stated objective, systematic literature review was employed. Sixty seven papers were downloaded in usability evaluation for m-commerce and related areas; twenty one most relevant studies were selected for review in order to extract the appropriate information. The results from the review shows that heuristic evaluation, formal test and think aloud methods are the most commonly used methods in m-commerce application in comparison to cognitive walkthrough and the informal test methods. Moreover, most of the studies applied control experiment (33.3% of the total studies); other studies that applied case study for usability evaluation are 14.28%. The results from this paper provide additional knowledge to the usability practitioners and research community for the current state and use of usability techniques in m-commerce application.

  14. Usability in a cultural context

    DEFF Research Database (Denmark)

    Clemmensen, Torkil; Yammiyavar, Pradeep; Ørngreen, Rikke

    2010-01-01

    This paper focuses on presenting and discussing the aim, context, challenges, results, and impact of the Cultural usability project named as CultUsab. This project was a four year international research effort from 2006 to 2009, which was supported by a grant for the Danish Research Councils...... for Independent Research in Culture and Communication. The project aimed at innovating processes in Information and Communication Technology development through an understanding of culturally sensitive aspects of usability evaluation methods....

  15. Expanding Usability of Virtual Network Laboratory in IT Engineering Education

    Directory of Open Access Journals (Sweden)

    Dalibor M Dobrilovic

    2013-02-01

    Full Text Available This paper deals with importance of virtual network laboratories usage in IT engineering education. It presents the particular virtual network laboratory model developed for usage in Computer Networks course as well. This virtual network laboratory, called VNLab, is based on virtualization technology. It has been successfully tested in educational process of Computer Network course for IT undergraduate students. Its usability for network related courses is analyzed by comparison of recommended curricula’s of world organizations such as IEEE, ACM and AIS. This paper is focused on expanding the usability of this virtual network laboratory to other non-network related courses. The primary expansion field is in domain of IT System Administration, IT Systems and Data Security and Operating Systems as well. The possible learning scenarios, learning tools and concepts for making this system applicable in these three additional fields are presented by the analyses of compatibility with recommended learning topics and outcomes by IEEE, ACM and AIS.

  16. Why Citizen Science Without Usability Testing Will Underperform

    Science.gov (United States)

    Romano, C.; Gay, P.; Owens, R.; Burlea, G.

    2017-12-01

    Citizen science projects must undergo usability testing and optimization if they are to meet their stated goals. This presentation will include video of usability tests conducted upon citizen science websites. Usability testing is essential to the success of online interaction, however, citizen science projects have just begun to include this critical activity. Interaction standards in citizen science lag behind those of commercial interests, and published research on this topic is limited. Since online citizen science is by definition, an exchange of information, a clear understanding of how users experience an online project is essential to informed decision-making. Usability testing provides that insight. Usability testing collects data via direct observation of a person while she interacts with a digital product, such as a citizen science website. The test participant verbalizes her thoughts while using the website or application; the moderator follows the participant and captures quantitative measurement of the participant's confidence of success as she advances through the citizen science project. Over 15 years of usability testing, we have observed that users who do not report a consistent sense of progress are likely to abandon a website after as few as three unrewarding interactions. Since citizen science is also a voluntary activity, ensuring seamless interaction for users is mandatory. Usability studies conducted on citizen science websites demonstrate that project teams frequently underestimate a user's need for context and ease of use. Without usability testing, risks to online citizen science projects include high bounce rate (users leave the website without taking any action), abandonment (of the website, tutorials, registration), misunderstanding instructions (causing disorientation and erroneous conclusions), and ultimately, underperforming projects.

  17. Carrier-Based Drug Delivery System for Treatment of Acne

    Science.gov (United States)

    Vyas, Amber; Kumar Sonker, Avinesh

    2014-01-01

    Approximately 95% of the population suffers at some point in their lifetime from acne vulgaris. Acne is a multifactorial disease of the pilosebaceous unit. This inflammatory skin disorder is most common in adolescents but also affects neonates, prepubescent children, and adults. Topical conventional systems are associated with various side effects. Novel drug delivery systems have been used to reduce the side effect of drugs commonly used in the topical treatment of acne. Topical treatment of acne with active pharmaceutical ingredients (API) makes direct contact with the target site before entering the systemic circulation which reduces the systemic side effect of the parenteral or oral administration of drug. The objective of the present review is to discuss the conventional delivery systems available for acne, their drawbacks, and limitations. The advantages, disadvantages, and outcome of using various carrier-based delivery systems like liposomes, niosomes, solid lipid nanoparticles, and so forth, are explained. This paper emphasizes approaches to overcome the drawbacks and limitations associated with the conventional system and the advances and application that are poised to further enhance the efficacy of topical acne formulations, offering the possibility of simplified dosing regimen that may improve treatment outcomes using novel delivery system. PMID:24688376

  18. Safeguarding nuclear weapon: Usable materials in Russia

    International Nuclear Information System (INIS)

    Cochran, T.

    1998-01-01

    Both the United States and Russia are retaining as strategic reserves more plutonium and HEU for potential reuse as weapons, than is legitimately needed. Both have engaged in discussions and have programs in various stages of development to dispose of excess plutonium and HEU. These fissile material disposition programs will take decades to complete. In the interim there will be, as there is now, hundreds of tons of separated weapon-usable fissile material stored in tens of thousands of transportable canisters, each containing from a few to several tons of kgs of weapon-usable fissile material. This material must be secured against theft and unauthorized use. To have high confidence that the material is secure, one must establish criteria against which the adequacy of the protective systems can be judged. For example, one finds such criteria in US Nuclear Regulatory Commission (USNRC) regulations for the protection of special nuclear materials

  19. Usability Evaluation for Business Intelligence Applications: A User Support Perspective

    Directory of Open Access Journals (Sweden)

    Chrisna Jooste

    2014-08-01

    Full Text Available Business Intelligence (BI applications provide business information to drive decision support. Usability is one of the factors determining the optimal use and eventual benefit derived from BI applications. The documented need for more BI usability research together with the practical necessity for BI evaluation guidelines in the mining industry provides the rationale for this study. The purpose of the study was to investigate the usability evaluation of BI applications in the context of a coal mining organization. The research is guided by the question: How can existing usability criteria be customized to evaluate the usability of BI applications. The research design included user observation, heuristic evaluation and a survey. Based on observations made during user support on a BI application used at a coal mining organization a log of usability issues was compiled. The usability issues extracted from this log was compared and contrasted with general usability criteria from literature to synthesize an initial set of BI usability evaluation criteria. These criteria were used as the basis for a heuristic evaluation of the BI application used at the coal mining organization. The same BI application was also evaluated using the Software Usability Measurement Inventory (SUMI standardized questionnaire. The results from the two evaluations were triangulated and then compared with the BI user issues again to contextualize the findings and synthesize a validated and refined set of criteria. The main contribution of the study is the usability evaluation criteria for BI applications presented as guidelines. These guidelines deviate from existing evaluation guidelines in the emphasis on information architecture, learnability and operability.

  20. Exploring the Role of Usability in the Software Process: A Study of Irish Software SMEs

    Science.gov (United States)

    O'Connor, Rory V.

    This paper explores the software processes and usability techniques used by Small and Medium Enterprises (SMEs) that develop web applications. The significance of this research is that it looks at development processes used by SMEs in order to assess to what degree usability is integrated into the process. This study seeks to gain an understanding into the level of awareness of usability within SMEs today and their commitment to usability in practice. The motivation for this research is to explore the current development processes used by SMEs in developing web applications and to understand how usability is represented in those processes. The background for this research is provided by the growth of the web application industry beyond informational web sites to more sophisticated applications delivering a broad range of functionality. This paper presents an analysis of the practices of several Irish SMEs that develop web applications through a series of case studies. With the focus on SMEs that develop web applications as Management Information Systems and not E-Commerce sites, informational sites, online communities or web portals. This study gathered data about the usability techniques practiced by these companies and their awareness of usability in the context of the software process in those SMEs. The contribution of this study is to further the understanding of the current role of usability within the software development processes of SMEs that develop web applications.

  1. Systemic gene delivery to the central nervous system using Adeno-associated virus

    Directory of Open Access Journals (Sweden)

    Mathieu eBOURDENX

    2014-06-01

    Full Text Available Adeno-associated virus (AAV-mediated gene delivery has emerged as an effective and safe tool for both preclinical and clinical studies of neurological disorders. The recent discovery that several serotypes are able to cross the blood-brain-barrier when administered systemically has been a real breakthrough in the field of neurodegenerative diseases. Widespread transgene expression after systemic injection could spark interest as a therapeutic approach. Such strategy will avoid invasive brain surgery and allow non-focal gene therapy promising for CNS diseases affecting large portion of the brain. Here, we will review the recent results achieved through different systemic routes of injection generated in the last decade using systemic AAV-mediated delivery and propose a brief assessment of their values. In particular, we emphasize how the methods used for virus engineering could improve brain transduction after peripheral delivery.

  2. Getting a technology-based diabetes intervention ready for prime time: a review of usability testing studies.

    Science.gov (United States)

    Lyles, Courtney R; Sarkar, Urmimala; Osborn, Chandra Y

    2014-10-01

    Consumer health technologies can educate patients about diabetes and support their self-management, yet usability evidence is rarely published even though it determines patient engagement, optimal benefit of any intervention, and an understanding of generalizability. Therefore, we conducted a narrative review of peer-reviewed articles published from 2009 to 2013 that tested the usability of a web- or mobile-delivered system/application designed to educate and support patients with diabetes. Overall, the 23 papers included in our review used mixed (n = 11), descriptive quantitative (n = 9), and qualitative methods (n = 3) to assess usability, such as documenting which features performed as intended and how patients rated their experiences. More sophisticated usability evaluations combined several complementary approaches to elucidate more aspects of functionality. Future work pertaining to the design and evaluation of technology-delivered diabetes education/support interventions should aim to standardize the usability testing processes and publish usability findings to inform interpretation of why an intervention succeeded or failed and for whom.

  3. Lipid nanoparticles as drug/gene delivery systems to the retina.

    Science.gov (United States)

    del Pozo-Rodríguez, Ana; Delgado, Diego; Gascón, Alicia R; Solinís, Maria Ángeles

    2013-03-01

    This review highlights the application of lipid nanoparticles (Solid Lipid Nanoparticles, Nanostructured Lipid Carriers, or Lipid Drug Conjugates) as effective drug/gene delivery systems for retinal diseases. Most drug products for ocular disease treatment are marketed as eye drop formulations but, due to ocular barriers, the drug concentration in the retina hardly ever turns out to be effective. Up to this date, several delivery systems have been designed to deliver drugs to the retina. Drug delivery strategies may be classified into 3 groups: noninvasive techniques, implants, and colloidal carriers. The best known systems for drug delivery to the posterior eye are intravitreal implants; in fact, some of them are being clinically used. However, their long-term accumulation might impact the patient's vision. On the contrary, colloidal drug delivery systems (microparticles, liposomes, or nanoparticles) can be easily administered in a liquid form. Nanoparticular systems diffuse rapidly and are better internalized in ocular tissues than microparticles. In comparison with liposomes, nanoparticles have a higher loading capacity and are more stable in biological fluids and during storage. In addition, their capacity to adhere to the ocular surface and interact with the endothelium makes these drug delivery systems interesting as new therapeutic tools in ophthalmology. Within the group of nanoparticles, those composed of lipids (Solid Lipid Nanoparticles, Nanostructred Lipid Carriers, and Lipid Drug Conjugates) are more biocompatible, easy to produce at large scale, and they may be autoclaved or sterilized. The present review summarizes scientific results that evidence the potential application of lipid nanoparticles as drug delivery systems for the retina and also as nonviral vectors in gene therapy of retina disorders, although much more effort is still needed before these lipidic systems could be available in the market.

  4. Methods and Tools for Ethical Usability

    Science.gov (United States)

    Kavathatzopoulos, Iordanis; Kostrzewa, Agata; Laaksoharju, Mikael

    The objectives of the tutorial are to provide knowledge of basic ethical, psychological and organizational theories that are relevant to consider ethical aspects during design and use of IT systems; knowledge and skills about handling and solving ethical problems in connection with design and use of IT-systems; and skills in using questionnaires, surveys, interviews and the like in connection with software development and IT-use. It contains lectures, workshop and exercises; use of special tools to identify and consider IT ethical issues during planning, construction, installation and use of IT systems; and group exercises where the participants train their ethical skills on IT ethical conflicts and problems. Intended participants are system developers, purchasers, usability experts, academics, HCI teachers.

  5. Mobile App Delivery of the EORTC QLQ-C30 Questionnaire to Assess Health-Related Quality of Life in Oncological Patients: Usability Study.

    Science.gov (United States)

    Kessel, Kerstin A; Vogel, Marco Me; Alles, Anna; Dobiasch, Sophie; Fischer, Hanna; Combs, Stephanie E

    2018-02-20

    Mobile apps are evolving in the medical field. However, ongoing discussions have questioned whether such apps are really valuable and whether patients will accept their use in day-to-day clinical life. Therefore, we initiated a usability study in our department. We present our results of the first app prototype and patient testing of health-related quality of life (HRQoL) assessment in oncological patients. We developed an app prototype for the iOS operating system within eight months in three phases: conception, initial development, and pilot testing. For the HRQoL assessment, we chose to implement only the European Organization for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire-Core 30 (QLQ-C30; German version 3). Usability testing was conducted for three months. Participation was voluntary and pseudonymized. After completion of the QLQ-C30 questionnaire using iPads provided by our department, we performed a short survey with 10 questions. This survey inquired about patients' opinions regarding general aspects, including technical advances in medicine, mobile and app assistance during cancer treatment, and the app-specific functions (eg, interface and navigation). After logging into the app, the user can choose between starting a questionnaire, reviewing answers (administrators only), and logging out. The questionnaire is displayed with the same information, questions, and answers as on the original QLQ-C30 sheet. No alterations in wording were made. Usability was tested with 81 patients; median age was 55 years. The median time for completing the HRQoL questionnaire on the iPad was 4.0 minutes. Of all participants, 84% (68/81) owned a mobile device. Similarly, 84% (68/81) of participants would prefer a mobile version of the HRQoL questionnaire instead of a paper-based version. Using the app in daily life during and after cancer treatment would be supported by 83% (67/81) of participants. In the prototype version of the app, data were

  6. Virtual Reality for Architectural or Territorial Representations: Usability Perceptions

    Directory of Open Access Journals (Sweden)

    Atta Idrawani Zaini

    2017-05-01

    Full Text Available Virtual reality (VR is widely being researched within various aspects of real-world applications. As architecture and urban design are very much adhered to evaluating and designing space, physical representations are deemed as incompetent to deliver a full-scale depiction of a space. Similarly, digital models are very much also limited in that sense. VR can deliver a full-scale virtual environment (VE, tricking users to be immersed in the replicated environment. This is an advantage for the aforementioned design disciplines, as more relatable and realistic depiction of a space can be modelled. The notion of its usability has become important to be understood from the perspective of architecture and urban design. This paper measured the respondents’ perceptions of VR’s usability through measuring its quality of use based on several criteria. The criteria established were the ease of use, usefulness, and satisfaction. Different levels of architectural details were decided as a form of control. A total of N=96 randomly selected respondents from various backgrounds participated in the survey as they were divided into four different group of treatments. Each group experienced a different VE with different level of architectural details. The first section of analysis is a one-sample analysis and the second is a group difference analysis. From the first analysis, it was found that the respondents perceived VR as a usable tool for architectural or territorial representation. Using Kruskal-Wallis test, it was found that there was no statistically significant difference between groups, suggesting that the respondents perceived VR as usable regardless of the level of architectural details. As this paper used perception data based on the quality of use alone, the efficiency of VR system was not measured. Thus, this paper recommends further studies to be conducted on the system’s efficiency to reflect its usability in full extent.

  7. A Survey of Usability Practices in Free/Libre/Open Source Software

    Science.gov (United States)

    Paul, Celeste Lyn

    A review of case studies about usability in eight Free/Libre/Open Source Software (FLOSS) projects showed that an important issue regarding a usability initiative in the project was the lack of user research. User research is a key component in the user-centered design (UCD) process and a necessary step for creating usable products. Reasons why FLOSS projects suffered from a lack of user research included poor or unclear project leadership, cultural differences between developer and designers, and a lack of usability engineers. By identifying these critical issues, the FLOSS usability community can begin addressing problems in the efficacy of usability activities and work towards creating more usable FLOSS products.

  8. Progress and Challenges in Developing Aptamer-Functionalized Targeted Drug Delivery Systems

    Directory of Open Access Journals (Sweden)

    Feng Jiang

    2015-10-01

    Full Text Available Aptamers, which can be screened via systematic evolution of ligands by exponential enrichment (SELEX, are superior ligands for molecular recognition due to their high selectivity and affinity. The interest in the use of aptamers as ligands for targeted drug delivery has been increasing due to their unique advantages. Based on their different compositions and preparation methods, aptamer-functionalized targeted drug delivery systems can be divided into two main categories: aptamer-small molecule conjugated systems and aptamer-nanomaterial conjugated systems. In this review, we not only summarize recent progress in aptamer selection and the application of aptamers in these targeted drug delivery systems but also discuss the advantages, challenges and new perspectives associated with these delivery systems.

  9. A Usability Study of Users' Perceptions toward a Multimedia Computer-Assisted Learning Tool for Neuroanatomy

    Science.gov (United States)

    Gould, Douglas J.; Terrell, Mark A.; Fleming, Jo

    2008-01-01

    This usability study evaluated users' perceptions of a multimedia prototype for a new e-learning tool: Anatomy of the Central Nervous System: A Multimedia Course. Usability testing is a collection of formative evaluation methods that inform the developmental design of e-learning tools to maximize user acceptance, satisfaction, and adoption.…

  10. Microcontainers - an oral drug delivery system for poorly soluble drugs

    DEFF Research Database (Denmark)

    Nielsen, Line Hagner; Petersen, Ritika Singh; Marizza, Paolo

    In oral delivery, it can sometimes be necessary to employ drug delivery systems to achieve targeted delivery to the intestine. Microcontainers are polymeric, cylindrical devices in the micrometer size range (Figure 1), and are suggested as a promising oral drug delivery system [1],[2]. The purpose...... of these studies was to fabricate microcontainers in either SU-8 or biodegradable poly-L-lactic acid (PLLA), and fill the microcontainers with poorly soluble drugs. Furthermore, the application of the microcontainers as an oral drug delivery system was investigated in terms of release, in situ intestinal perfusion...... medium at pH 6.5 was observed. In situ intestinal perfusions were performed in rats of the Eudragit-coated ASSF-filled microcontainers and compared to a furosemide solution. At the end of the study, the small intestine was harvested from the rat and imaged under a light microscope. The absorption rate...

  11. A task-specific interactive game-based virtual reality rehabilitation system for patients with stroke: a usability test and two clinical experiments.

    Science.gov (United States)

    Shin, Joon-Ho; Ryu, Hokyoung; Jang, Seong Ho

    2014-03-06

    Virtual reality (VR) is not commonly used in clinical rehabilitation, and commercial VR gaming systems may have mixed effects in patients with stroke. Therefore, we developed RehabMaster™, a task-specific interactive game-based VR system for post-stroke rehabilitation of the upper extremities, and assessed its usability and clinical efficacy. A participatory design and usability tests were carried out for development of RehabMaster with representative user groups. Two clinical trials were then performed. The first was an observational study in which seven patients with chronic stroke received 30 minutes of RehabMaster intervention per day for two weeks. The second was a randomised controlled trial of 16 patients with acute or subacute stroke who received 10 sessions of conventional occupational therapy only (OT-only group) or conventional occupational therapy plus 20 minutes of RehabMaster intervention (RehabMaster + OT group). The Fugl-Meyer Assessment score (FMA), modified Barthel Index (MBI), adverse effects, and drop-out rate were recorded. The requirements of a VR system for stroke rehabilitation were established and incorporated into RehabMaster. The reported advantages from the usability tests were improved attention, the immersive flow experience, and individualised intervention. The first clinical trial showed that the RehabMaster intervention improved the FMA (P = .03) and MBI (P = .04) across evaluation times. The second trial revealed that the addition of RehabMaster intervention tended to enhance the improvement in the FMA (P = .07) but did not affect the improvement in the MBI. One patient with chronic stroke left the trial, and no adverse effects were reported. The RehabMaster is a feasible and safe VR system for enhancing upper extremity function in patients with stroke.

  12. Templates for Cross-Cultural and Culturally Specific Usability Testing

    DEFF Research Database (Denmark)

    Clemmensen, Torkil

    2011-01-01

    The cultural diversity of users of technology challenges our methods for usability testing. This article suggests templates for cross-culturally and culturally specific usability testing, based on studies of usability testing in companies in Mumbai, Beijing, and Copenhagen. Study 1 was a cross...... tests. The result was the construction of templates for usability testing. The culturally specific templates were in Mumbai “user-centered evaluation,” Copenhagen “client-centered evaluation,” and Beijing “evaluator-centered evaluation.” The findings are compared with related research...

  13. Usability evaluation of a web-based support system for people with a schizophrenia diagnosis.

    Science.gov (United States)

    van der Krieke, Lian; Emerencia, Ando C; Aiello, Marco; Sytema, Sjoerd

    2012-02-06

    Routine Outcome Monitoring (ROM) is a systematic way of assessing service users' health conditions for the purpose of better aiding their care. ROM consists of various measures used to assess a service user's physical, psychological, and social condition. While ROM is becoming increasingly important in the mental health care sector, one of its weaknesses is that ROM is not always sufficiently service user-oriented. First, clinicians tend to concentrate on those ROM results that provide information about clinical symptoms and functioning, whereas it has been suggested that a service user-oriented approach needs to focus on personal recovery. Second, service users have limited access to ROM results and they are often not equipped to interpret them. These problems need to be addressed, as access to resources and the opportunity to share decision making has been indicated as a prerequisite for service users to become a more equal partner in communication with their clinicians. Furthermore, shared decision making has been shown to improve the therapeutic alliance and to lead to better care. Our aim is to build a web-based support system which makes ROM results more accessible to service users and to provide them with more concrete and personalized information about their functioning (ie, symptoms, housing, social contacts) that they can use to discuss treatment options with their clinician. In this study, we will report on the usability of the web-based support system for service users with schizophrenia. First, we developed a prototype of a web-based support system in a multidisciplinary project team, including end-users. We then conducted a usability study of the support system consisting of (1) a heuristic evaluation, (2) a qualitative evaluation and (3) a quantitative evaluation. Fifteen service users with a schizophrenia diagnosis and four information and communication technology (ICT) experts participated in the study. The results show that people with a

  14. Advanced and controlled drug delivery systems in clinical disease management

    NARCIS (Netherlands)

    Brouwers, JRBJ

    1996-01-01

    Advanced and controlled drug delivery systems are important for clinical disease management. In this review the most important new systems which have reached clinical application are highlighted. Microbiologically controlled drug delivery is important for gastrointestinal diseases like ulcerative

  15. Commissioning of cryogen delivery system for superconducting cyclotron magnet

    International Nuclear Information System (INIS)

    Pal, G.; Nandi, C.; Bhattacharyya, T.K.; Chaudhuri, J.; Bhandari, R.K.

    2005-01-01

    A K-500 superconducting cyclotron is being constructed at VECC Kolkata. The cryogen delivery system distributes liquid helium and liquid nitrogen to the superconducting cyclotron. Liquid helium is required to cool the cyclotron magnet and cryopanels. Liquid nitrogen is used to reduce the capacity of the helium liquefier. This paper describes the system, the current status and the commissioning experiences of cryogen delivery system for cyclotron magnet. (author)

  16. Nanostructured lipid carriers system: recent advances in drug delivery.

    Science.gov (United States)

    Iqbal, Md Asif; Md, Shadab; Sahni, Jasjeet Kaur; Baboota, Sanjula; Dang, Shweta; Ali, Javed

    2012-12-01

    Nanostructured lipid carrier (NLC) is second generation smarter drug carrier system having solid matrix at room temperature. This carrier system is made up of physiological, biodegradable and biocompatible lipid materials and surfactants and is accepted by regulatory authorities for application in different drug delivery systems. The availability of many products in the market in short span of time reveals the success story of this delivery system. Since the introduction of the first product, around 30 NLC preparations are commercially available. NLC exhibit superior advantages over other colloidal carriers viz., nanoemulsions, polymeric nanoparticles, liposomes, SLN etc. and thus, have been explored to more extent in pharmaceutical technology. The whole set of unique advantages such as enhanced drug loading capacity, prevention of drug expulsion, leads to more flexibility for modulation of drug release and makes NLC versatile delivery system for various routes of administration. The present review gives insights on the definitions and characterization of NLC as colloidal carriers including the production techniques and suitable formulations. This review paper also highlights the importance of NLC in pharmaceutical applications for the various routes of drug delivery viz., topical, oral, pulmonary, ocular and parenteral administration and its future perspective as a pharmaceutical carrier.

  17. Human Factors for Nursing: From In-Situ Testing to Mobile Usability Engineering.

    Science.gov (United States)

    Kushniruk, Andre W; Borycki, Elizabeth M; Solvoll, Terje; Hullin, Carola

    2016-01-01

    The tutorial goal is to familiarize participants with human aspects of health informatics and human-centered approaches to the design, evaluation and deployment of both usable and safe healthcare information systems. The focus will be on demonstrating and teaching practical and low-cost methods for evaluating mobile applications in nursing. Basic background to testing methods will be provided, followed by live demonstration of the methods. Then the audience will break into small groups to explore the application of the methods to applications of interest (there will be a number of possible applications that will be available for applications in areas such as electronic health records and decision support, however, if the groups have applications of specific interest to them that will be possible). The challenges of conducting usability testing, and in particular mobile usability testing will be discussed along with practical solutions. The target audience includes practicing nurses and nurse researchers, nursing informatics specialists, nursing students, nursing managers and health informatics professionals interested in improving the usability and safety of healthcare applications.

  18. Cultural Cognition in Usability Evaluation

    DEFF Research Database (Denmark)

    Clemmensen, Torkil; Hertzum, Morten; Hornbæk, Kasper Anders Søren

    2009-01-01

    We discuss the impact of cultural differences on usability evaluations that are based on the thinking-aloud method (TA). The term ‘cultural differences' helps distinguish differences in the perception and thinking of Westerners (people from Western Europe and US citizens with European origins...... and evaluator. In conclusion, we point to the importance of matching the task presentation to users' cultural background, the different effects of thinking aloud on task performance between Easterners and Westerners, the differences in nonverbal behaviour that affect usability problem detection, and, finally...

  19. Cultural Cognition in Usability Evaluation

    DEFF Research Database (Denmark)

    Clemmensen, Torkil; Hertzum, Morten; Hornbæk, Kasper Anders Søren

    2009-01-01

    We discuss the impact of cultural differences on usability evaluations that are based on the thinking-aloud method (TA). The term ‘cultural differences’ helps distinguish differences in the perception and thinking of Westerners (people from Western Europe and US citizens with European origins...... and evaluator. In conclusion, we point to the importance of matching the task presentation to users’ cultural background, the different effects of thinking aloud on task performance between Easterners and Westerners, the differences in nonverbal behaviour that affect usability problem detection, and, finally...

  20. Effect of improving the usability of an e-learning resource: a randomized trial.

    Science.gov (United States)

    Davids, Mogamat Razeen; Chikte, Usuf M E; Halperin, Mitchell L

    2014-06-01

    Optimizing the usability of e-learning materials is necessary to reduce extraneous cognitive load and maximize their potential educational impact. However, this is often neglected, especially when time and other resources are limited. We conducted a randomized trial to investigate whether a usability evaluation of our multimedia e-learning resource, followed by fixing of all problems identified, would translate into improvements in usability parameters and learning by medical residents. Two iterations of our e-learning resource [version 1 (V1) and version 2 (V2)] were compared. V1 was the first fully functional version and V2 was the revised version after all identified usability problems were addressed. Residents in internal medicine and anesthesiology were randomly assigned to one of the versions. Usability was evaluated by having participants complete a user satisfaction questionnaire and by recording and analyzing their interactions with the application. The effect on learning was assessed by questions designed to test the retention and transfer of knowledge. Participants reported high levels of satisfaction with both versions, with good ratings on the System Usability Scale and adjective rating scale. In contrast, analysis of video recordings revealed significant differences in the occurrence of serious usability problems between the two versions, in particular in the interactive HandsOn case with its treatment simulation, where there was a median of five serious problem instances (range: 0-50) recorded per participant for V1 and zero instances (range: 0-1) for V2 (P e-learning resource resulted in significant improvements in usability. This is likely to translate into improved motivation and willingness to engage with the learning material. In this population of relatively high-knowledge participants, learning scores were similar across the two versions. Copyright © 2014 The American Physiological Society.

  1. Building a Remote Usability Testing Body of Knowledge (RUTBOK)

    DEFF Research Database (Denmark)

    Lizano, Fulvio; Stage, Jan

    2012-01-01

    Remote Usability Testing (RUT) is an alternative method of usability evaluations. The main aim of RUT is the reduction of costs in the usability evaluation process. Since middle of the 90s RUT, has emerged as a technique which seems as is gaining maturity across the time. In general any discipline...

  2. The Usability Expert’s Fear of Agility

    DEFF Research Database (Denmark)

    Nielsen, Lene; Madsen, Sabine

    2012-01-01

    This paper contributes to the HCI literature on usability practice with insights about the empirical challenges and global emerging practices caused by the advent of agile software development (ASD). In the paper we report from a worldwide study involving 12 usability professionals from 12 differ...

  3. Nebuliser systems for drug delivery in cystic fibrosis.

    Science.gov (United States)

    Daniels, Tracey; Mills, Nicola; Whitaker, Paul

    2013-04-30

    Nebuliser systems are used to deliver medications to control the symptoms and the progression of lung disease in people with cystic fibrosis. Many types of nebuliser systems are available for use with various medications; however, there has been no previous systematic review which has evaluated these systems. To evaluate effectiveness, safety, burden of treatment and adherence to nebulised therapy using different nebuliser systems for people with cystic fibrosis. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group Trials Register comprising references identified from comprehensive electronic database searches, handsearching of relevant journals and abstract books of conference proceedings. We searched the reference lists of each study for additional publications and approached the manufacturers of both nebuliser systems and nebulised medications for published and unpublished data. Date of the most recent search: 15 Oct 2012. Randomised controlled trials or quasi-randomised controlled trials comparing nebuliser systems including conventional nebulisers, vibrating mesh technology systems, adaptive aerosol delivery systems and ultrasonic nebuliser systems. Two authors independently assessed studies for inclusion. They also independently extracted data and assessed the risk of bias. A third author assessed studies where agreement could not be reached. The search identified 40 studies with 20 of these (1936 participants) included in the review. These studies compared the delivery of tobramycin, colistin, dornase alfa, hypertonic sodium chloride and other solutions through the different nebuliser systems. This review demonstrates variability in the delivery of medication depending on the nebuliser system used. Conventional nebuliser systems providing higher flows, higher respirable fractions and smaller particles decrease treatment time, increase deposition and may be preferred by people with CF, as compared to conventional nebuliser systems providing

  4. Delivery systems and local administration routes for therapeutic siRNA.

    Science.gov (United States)

    Vicentini, Fabiana Testa Moura de Carvalho; Borgheti-Cardoso, Lívia Neves; Depieri, Lívia Vieira; de Macedo Mano, Danielle; Abelha, Thais Fedatto; Petrilli, Raquel; Bentley, Maria Vitória Lopes Badra

    2013-04-01

    With the increasing number of studies proposing new and optimal delivery strategies for the efficacious silencing of gene-related diseases by the local administration of siRNAs, the present review aims to provide a broad overview of the most important and latest developments of non-viral siRNA delivery systems for local administration. Moreover, the main disease targets for the local delivery of siRNA to specific tissues or organs, including the skin, the lung, the eye, the nervous system, the digestive system and the vagina, were explored.

  5. Spray-on transdermal drug delivery systems.

    Science.gov (United States)

    Ibrahim, Sarah A

    2015-02-01

    Transdermal drug delivery possesses superior advantages over other routes of administration, particularly minimizing first-pass metabolism. Transdermal drug delivery is challenged by the barrier nature of skin. Numerous technologies have been developed to overcome the relatively low skin permeability, including spray-on transdermal systems. A transdermal spray-on system (TSS) usually consists of a solution containing the drug, a volatile solvent and in many cases a chemical penetration enhancer. TSS promotes drug delivery via the complex interplay between solvent evaporation and drug-solvent drag into skin. The volatile solvent carries the drug into the upper layers of the stratum corneum, and as the volatile solvent evaporates, an increase in the thermodynamic activity of the drug occurs resulting in an increased drug loading in skin. TSS is easily applied, delivering flexible drug dosage and associated with lower incidence of skin irritation. TSS provides a fast-drying product where the volatile solvent enables uniform drug distribution with minimal vehicle deposition on skin. TSS ensures precise dose administration that is aesthetically appealing and eliminates concerns of residual drug associated with transdermal patches. Furthermore, it provides a better alternative to traditional transdermal products due to ease of product development and manufacturing.

  6. Otic drug delivery systems: formulation principles and recent developments.

    Science.gov (United States)

    Liu, Xu; Li, Mingshuang; Smyth, Hugh; Zhang, Feng

    2018-04-25

    Disorders of the ear severely impact the quality of life of millions of people, but the treatment of these disorders is an ongoing, but often overlooked challenge particularly in terms of formulation design and product development. The prevalence of ear disorders has spurred significant efforts to develop new therapeutic agents, but perhaps less innovation has been applied to new drug delivery systems to improve the efficacy of ear disease treatments. This review provides a brief overview of physiology, major diseases, and current therapies used via the otic route of administration. The primary focuses are on the various administration routes and their formulation principles. The article also presents recent advances in otic drug deliveries as well as potential limitations. Otic drug delivery technology will likely evolve in the next decade and more efficient or specific treatments for ear disease will arise from the development of less invasive drug delivery methods, safe and highly controlled drug delivery systems, and biotechnology targeting therapies.

  7. Safety design integrated in the building delivery system

    DEFF Research Database (Denmark)

    Jørgensen, Kirsten

    2013-01-01

    . The purpose of this article is to demonstrate how safety and health can be integrated in the design phases integrated in the management delivery systems within construction, The method for the research was to go through the building delivery system step by step and create a normative description of what, when......In construction, it is important to view safety and health as an integrated part of the way that “designers” are working. The designers cowers architects, constructors, engineers and others who carry out their consulting services in the design phase of a construction project. The philosophy...... and how to fully integrate safety in each part of the process. The result is a concept and guideline including control forms for how to integrate safety design in the Building Delivery System plus what to do and when. The concept has been tested in an educational context. The practical value...

  8. Pharmacokinetics of a 5-fluorouracil liposomal delivery system.

    Science.gov (United States)

    Simmons, S T; Sherwood, M B; Nichols, D A; Penne, R B; Sery, T; Spaeth, G L

    1988-01-01

    A liposomal delivery system was developed in an attempt to prolong ocular levels of 5-fluorouracil for glaucoma filtering surgery. The pharmacokinetics of the 5-fluorouracil liposomal delivery system were studied in normal pigmented rabbits with 5-fluorouracil labelled with carbon-14 (C-14). 14C 5-fluorouracil was incorporated into the liposomes at a concentration of 10 g/l and injected subconjunctivally in doses of 5 and 10 mg. Concentrations of 5-fluorouracil were assayed at 10 time intervals from 0.5 to 96 hours in cornea, sclera, and conjunctiva and at six time intervals from 0.5 to 12 hours in aqueous. Two peak concentrations were noted at approximately one and eight hours, with measurable levels present at 96 hours. This study demonstrates the ability of this liposomal delivery system to prolong levels of 5-fluorouracial in normal pigmented rabbits. PMID:3179257

  9. Safety design integrated in the Building Delivery System

    DEFF Research Database (Denmark)

    Jørgensen, Kirsten

    2012-01-01

    phases of the building delivery system by using the principle of the lean construction modelling. The method for the research was to go through the lean construction building delivery system step by step and create a normative description of what to do, when to do and how to do to fully integration...... of safety in each process. The group of participants who created the description had a high experience in a combination of research, safety and health in general and especial in construction and knowledge of the lean construction processes both from the clients perspective as well as from the designers...... and the consultants. The result is a concept and guideline including control schemes for how to integrate safety design in the lean construction building delivery system including what to do and when. The concept has been tested in an educational context and found useful by the designers. The practical value...

  10. An Overview of Clinical and Commercial Impact of Drug Delivery Systems

    Science.gov (United States)

    Anselmo, Aaron C.; Mitragotri, Samir

    2014-01-01

    Drug delivery systems are widely researched and developed to improve the delivery of pharmaceutical compounds and molecules. The last few decades have seen a marked growth of the field fueled by increased number of researchers, research funding, venture capital and the number of start-ups. Collectively, the growth has led to novel systems that make use of micro/nano-particles, transdermal patches, inhalers, drug reservoir implants and antibody-drug conjugates. While the increased research activity is clearly an indication of proliferation of the field, clinical and commercial translation of early-stage research ideas is critically important for future growth and interest in the field. Here, we will highlight some of the examples of novel drug delivery systems that have undergone such translation. Specifically, we will discuss the developments, advantages, limitations and lessons learned from: (i) microparticle-based depot formulations, (ii) nanoparticle-based cancer drugs, (iii) transdermal systems, (iv) oral drug delivery systems, (v) pulmonary drug delivery, (vi) implants and (vii) antibody-drug conjugates. These systems have impacted treatment of many prevalent diseases including diabetes, cancer and cardiovascular diseases, among others. At the same time, these systems are integral and enabling components of products that collectively generate annual revenues exceeding US $100 billion. These examples provide strong evidence of the clinical and commercial impact of drug delivery systems. PMID:24747160

  11. Clinical pathways for primary care: current use, interest and perceived usability.

    Science.gov (United States)

    Waters, Richard C; Toy, Jennifer M; Drechsler, Adam

    2018-02-26

    Translating clinical evidence to daily practice remains a challenge and may improve with clinical pathways. We assessed interest in and usability of clinical pathways by primary care professionals. An online survey was created. Interest in pathways for patient care and learning was assessed at start and finish. Participants completed baseline questions then pathway-associated question sets related to management of 2 chronic diseases. Perceived pathway usability was assessed using the system usability scale. Accuracy and confidence of answers was compared for baseline and pathway-assisted questions. Of 115 participants, 17.4% had used clinical pathways, the lowest of decision support tool types surveyed. Accuracy and confidence in answers significantly improved for all pathways. Interest in using pathways daily or weekly was above 75% for the respondents. There is low utilization of, but high interest in, clinical pathways by primary care clinicians. Pathways improve accuracy and confidence in answering written clinical questions.

  12. Understanding the organization of public health delivery systems: an empirical typology.

    Science.gov (United States)

    Mays, Glen P; Scutchfield, F Douglas; Bhandari, Michelyn W; Smith, Sharla A

    2010-03-01

    Policy discussions about improving the U.S. health care system increasingly recognize the need to strengthen its capacities for delivering public health services. A better understanding of how public health delivery systems are organized across the United States is critical to improvement. To facilitate the development of such evidence, this article presents an empirical method of classifying and comparing public health delivery systems based on key elements of their organizational structure. This analysis uses data collected through a national longitudinal survey of local public health agencies serving communities with at least 100,000 residents. The survey measured the availability of twenty core public health activities in local communities and the types of organizations contributing to each activity. Cluster analysis differentiated local delivery systems based on the scope of activities delivered, the range of organizations contributing, and the distribution of effort within the system. Public health delivery systems varied widely in organizational structure, but the observed patterns of variation suggested that systems adhere to one of seven distinct configurations. Systems frequently migrated from one configuration to another over time, with an overall trend toward offering a broader scope of services and engaging a wider range of organizations. Public health delivery systems exhibit important structural differences that may influence their operations and outcomes. The typology developed through this analysis can facilitate comparative studies to identify which delivery system configurations perform best in which contexts.

  13. Buccoadhesive drug delivery systems--extensive review on recent patents.

    Science.gov (United States)

    Pathan, Shadab A; Iqbal, Zeenat; Sahani, Jasjeet K; Talegaonkar, Sushma; Khar, Roop K; Ahmad, Farhan J

    2008-01-01

    Peroral administration of drugs, although most preferred by both clinicians and patients has several disadvantages such as hepatic first pass metabolism and enzymatic degradation within the GI tract, that prohibit oral administration of certain classes of drugs especially peptides and proteins. Consequently, other absorptive mucosae are considered as potential sites for administration of these drugs. Among the various transmucosal routes studied the buccal mucosa offers several advantages for controlled drug delivery for extended period of time. The mucosa is well supplied with both vascular and lymphatic drainage and first-pass metabolism in the liver and pre-systemic elimination in the gastrointestinal tract is avoided. The area is well suited for a retentive device and appears to be acceptable to the patient. With the right dosage form, design and formulation, the permeability and the local environment of the mucosa can be controlled and manipulated in order to accommodate drug permeation. Buccal drug delivery is thus a promising area for continued research with the aim of systemic and local delivery of orally inefficient drugs as well as feasible and attractive alternative for non-invasive delivery of potent protein and peptide drug molecules. Extensive review pertaining specifically to the patents relating to buccal drug delivery is currently available. However, many patents e.g. US patents 6, 585,997; US20030059376A1 etc. have been mentioned in few articles. It is the objective of this article to extensively review buccal drug delivery by discussing the recent patents available. Buccal dosage forms will also be reviewed with an emphasis on bioadhesive polymeric based delivery systems.

  14. Hydrogen storage and delivery system development: Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Handrock, J.L. [Sandia National Labs., Livermore, CA (United States)

    1996-10-01

    Hydrogen storage and delivery is an important element in effective hydrogen utilization for energy applications and is an important part of the FY1994-1998 Hydrogen Program Implementation Plan. This project is part of the Field Work Proposal entitled Hydrogen Utilization in Internal Combustion Engines (ICE). The goal of the Hydrogen Storage and Delivery System Development Project is to expand the state-of-the-art of hydrogen storage and delivery system design and development. At the foundation of this activity is the development of both analytical and experimental evaluation platforms. These tools provide the basis for an integrated approach for coupling hydrogen storage and delivery technology to the operating characteristics of potential hydrogen energy use applications. Results of the analytical model development portion of this project will be discussed. Analytical models have been developed for internal combustion engine (ICE) hybrid and fuel cell driven vehicles. The dependence of hydride storage system weight and energy use efficiency on engine brake efficiency and exhaust temperature for ICE hybrid vehicle applications is examined. Results show that while storage system weight decreases with increasing engine brake efficiency energy use efficiency remains relatively unchanged. The development, capability, and use of a recently developed fuel cell vehicle storage system model will also be discussed. As an example of model use, power distribution and control for a simulated driving cycle is presented. Model calibration results of fuel cell fluid inlet and exit temperatures at various fuel cell idle speeds, assumed fuel cell heat capacities, and ambient temperatures are presented. The model predicts general increases in temperature with fuel cell power and differences between inlet and exit temperatures, but under predicts absolute temperature values, especially at higher power levels.

  15. A proposal for a repertory-grid study of differences in Chinese, Danish, and Indian conceptions of usability: Cultural usability?

    DEFF Research Database (Denmark)

    Hertzum, Morten

    2006-01-01

    This is an unrefined proposal for a study that could form part of the exploratory phase of the Cultural Usability project. The proposed study compares three cultures (Chinese, Danish, and Indian) and two stakeholder groups (users and developers) with respect to their conceptions of usability....

  16. Adding SPICE to a Library Internet Site: A Recipe to Enhance Usability

    Directory of Open Access Journals (Sweden)

    Ingrid Tonnison

    2006-03-01

    Full Text Available Objective - To produce a highly- usable intranet site, use the project to explore the practical application of evidence-based librarianship (EBL, and refine the library's project management methodology. Methods - Evidence was gathered via a literature review, an online survey, scenario-based usability testing, and the completion of a usability checlist. Usability issues were then addressed, guided by the Research-Based Web Design and Usability Guidelines. Results - After a preliminary revision, the site achieved a usability index of 79% after application of the "Raward Library Usability Analysis Tool". Finding the information and supporting user tasks were identified as areas of weakness. Usability testing and cleint feedback supported these findings. After these issues were addressed by a major site redeveloment, the usability index increased to 98%. Conclusions - Raward's checklist is an easy and effective tool for measuring and identifying usability issues. Its value was enhanced by scenario-based usability testing, which yielded rich, client specific information. The application of EBL and project management princples ehnanced the outcomes of the project, and the professional development of the project team.

  17. Mechanical valve assembly for xenon 133 gas delivery systems

    Energy Technology Data Exchange (ETDEWEB)

    Round, W.H. (Royal Brisbane Hospital, Herston (Australia))

    Some gas delivery systems used in pulmonary ventilation scanning are unable to satisfactorily supply /sup 133/Xe gas to bed-ridden patients. A mechanical gas valve assembly to control the flow of gas in such systems was constructed. A commercially produced /sup 133/Xe gas delivery system when fitted with the new assembly was able to ventilate almost all patients whereas previously this could be achieved with approximately only 50% of patients.

  18. Stabilization challenges and formulation strategies associated with oral biologic drug delivery systems.

    Science.gov (United States)

    Truong-Le, Vu; Lovalenti, Phillip M; Abdul-Fattah, Ahmad M

    2015-10-01

    Delivery of proteins to mucosal tissues of GI tract typically utilize formulations which protect against proteolysis and target the mucosal tissues. Using case studies from literature and the authors' own work, the in-process stability and solid state storage stability of biopharmaceuticals formulated in delivery systems designed for oral delivery to the GI tract will be reviewed. Among the range of delivery systems, biodegradable polymer systems for protection and controlled release of proteins have been the most studied; hence these systems will be covered in greater depth. These delivery systems include polymeric biodegradable microspheres or nanospheres that contain proteins or vaccines, which are designed to reduce the number of administrations/inoculations and the total protein dose required to achieve the desired biological effect. Specifically, this review will include a landscape survey of the systems that have been studied, the manufacturing processes involved, stability through the manufacturing process, key pharmaceutical formulation parameters that impact stability of the encased proteins, and storage stability of the encapsulated proteins in these delivery systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Application of three-dimensional printing for colon targeted drug delivery systems.

    Science.gov (United States)

    Charbe, Nitin B; McCarron, Paul A; Lane, Majella E; Tambuwala, Murtaza M

    2017-01-01

    Orally administered solid dosage forms currently dominate over all other dosage forms and routes of administrations. However, human gastrointestinal tract (GIT) poses a number of obstacles to delivery of the drugs to the site of interest and absorption in the GIT. Pharmaceutical scientists worldwide have been interested in colon drug delivery for several decades, not only for the delivery of the drugs for the treatment of colonic diseases such as ulcerative colitis and colon cancer but also for delivery of therapeutic proteins and peptides for systemic absorption. Despite extensive research in the area of colon targeted drug delivery, we have not been able to come up with an effective way of delivering drugs to the colon. The current tablets designed for colon drug release depend on either pH-dependent or time-delayed release formulations. During ulcerative colitis the gastric transit time and colon pH-levels is constantly changing depending on whether the patient is having a relapse or under remission. Hence, the current drug delivery system to the colon is based on one-size-fits-all. Fails to effectively deliver the drugs locally to the colon for colonic diseases and delivery of therapeutic proteins and peptides for systemic absorption from the colon. Hence, to overcome the current issues associated with colon drug delivery, we need to provide the patients with personalized tablets which are specifically designed to match the individual's gastric transit time depending on the disease state. Three-dimensional (3D) printing (3DP) technology is getting cheaper by the day and bespoke manufacturing of 3D-printed tablets could provide the solutions in the form of personalized colon drug delivery system. This review provides a bird's eye view of applications and current advances in pharmaceutical 3DP with emphasis on the development of colon targeted drug delivery systems.

  20. Project Delivery System Mode Decision Based on Uncertain AHP and Fuzzy Sets

    Science.gov (United States)

    Kaishan, Liu; Huimin, Li

    2017-12-01

    The project delivery system mode determines the contract pricing type, project management mode and the risk allocation among all participants. Different project delivery system modes have different characteristics and applicable scope. For the owners, the selection of the delivery mode is the key point to decide whether the project can achieve the expected benefits, it relates to the success or failure of project construction. Under the precondition of comprehensively considering the influence factors of the delivery mode, the model of project delivery system mode decision was set up on the basis of uncertain AHP and fuzzy sets, which can well consider the uncertainty and fuzziness when conducting the index evaluation and weight confirmation, so as to rapidly and effectively identify the most suitable delivery mode according to project characteristics. The effectiveness of the model has been verified via the actual case analysis in order to provide reference for the construction project delivery system mode.

  1. Drug delivery system and radiation therapy

    International Nuclear Information System (INIS)

    Shibata, Tokushi

    2005-01-01

    This paper describes the review of radiation therapy, neutron capture therapy (NCT) and drug delivery system for the latter. In cancer radiation therapy, there are problems of body movement like breathing, needless irradiation of normal tissues, difficulty to decide the correct irradiation position and tumor morphology. NCT has advantages to overcome these, and since boron has a big cross section for thermal neutron, NPT uses the reaction 10 B(n, α) 7 Li in the target cancer which previously incorporated the boron-containing drug. During the period 1966-1996, 246 patients were treated with this in Japan and the treatment has been continued thereafter. The tasks for NCT are developments of drug delivery system efficient to deliver the drug into the tumor and of convenient neutron source like the accelerator. (S.I.)

  2. Description and Documentation of the Dental School Dental Delivery System.

    Science.gov (United States)

    Chase, Rosen and Wallace, Inc., Alexandria, VA.

    A study was undertaken to describe and document the dental school dental delivery system using an integrated systems approach. In late 1976 and early 1977, a team of systems analysts and dental consultants visited three dental schools to observe the delivery of dental services and patient flow and to interview administrative staff and faculty.…

  3. Better Usability and Technical Stability Could Lead to Better Work-Related Well-Being among Physicians.

    Science.gov (United States)

    Vainiomäki, Suvi; Aalto, Anna-Mari; Lääveri, Tinja; Sinervo, Timo; Elovainio, Marko; Mäntyselkä, Pekka; Hyppönen, Hannele

    2017-10-01

    Background and Objective Finnish physicians have been increasingly dissatisfied with poor usability of the electronic patient record (EPR) systems, which they have identified as an overload factor in their work. Our aim is to specify which factors in EPRs are associated with work-related well-being of physicians. Methods A web-based questionnaire was sent to Finnish physicians younger than 65 years; the responses (n = 3,781) represent one-fourth of these. This was a repetition of a survey in 2010, where this questionnaire was used for the first time. In addition to statements assessing usability, there were questions measuring time pressure and job control. The relation between usability and work well-being was investigated with hierarchical multivariate regression analyses: With time pressure and job control as dependent variables, EPR usability assessments and physicians' background information were used as independent variables. Results In the multivariate analyses, technical problems that are often experienced in the EPR were related to higher time pressure and lower job control. Active participation in the development of the EPR system was related to stronger time pressure and stronger job control. In addition, use of several systems daily and the experience of time-consuming documentation of patient information for statistical purposes (billing, national registries, and reporting) were related to higher time pressure, while those with longer experience with the EPR system and those experiencing easy-to-read nursing records reported higher job control. Conclusion To relieve time pressure and increase sense of job control experienced by physicians, usability, integrations, and stability of the EPR systems should be improved: fewer login procedures, easier readability of nursing records, and decreased need for separate documentation for statistical purposes. Physician participation in the EPR development would increase the feeling of job control, but

  4. Usability testing of an mHealth device for swallowing therapy in head and neck cancer survivors.

    Science.gov (United States)

    Constantinescu, Gabriela; Kuffel, Kristina; King, Ben; Hodgetts, William; Rieger, Jana

    2018-04-01

    The objective of this study was to conduct the first patient usability testing of a mobile health (mHealth) system for in-home swallowing therapy. Five participants with a history of head and neck cancer evaluated the mHealth system. After completing an in-application (app) tutorial with the clinician, participants were asked to independently complete five tasks: pair the device to the smartphone, place the device correctly, exercise, interpret progress displays, and close the system. Quantitative and qualitative methods were used to evaluate the effectiveness, efficiency, and satisfaction with the system. Critical changes to the app were found in three of the tasks, resulting in recommendations for the next iteration. These issues were related to ease of Bluetooth pairing, placement of device, and interpretation of statistics. Usability testing with patients identified issues that were essential to address prior to implementing the mHealth system in subsequent clinical trials. Of the usability methods used, video observation (synced screen capture with videoed gestures) revealed the most information.

  5. Revealing unawareness in usability related decision-making

    NARCIS (Netherlands)

    Harkema, C.L.E.

    2012-01-01

    Nowadays, many users experience usability issues with their electronic products. It does not work as they expect or otherwise irritates the user, so he becomes dissatisfied about the product and may even complain about it. Th ese numbers of complaints to companies and usability issues are high and

  6. Dimensions for hearing-impaired mobile application usability model

    Science.gov (United States)

    Nathan, Shelena Soosay; Hussain, Azham; Hashim, Nor Laily; Omar, Mohd Adan

    2017-10-01

    This paper discuss on the dimensions that has been derived for the hearing-impaired mobile applications usability model. General usability model consist of general dimension for evaluating mobile application however requirements for the hearing-impaired are overlooked and often scanted. This led towards mobile application developed for the hearing-impaired are left unused. It is also apparent that these usability models do not consider accessibility dimensions according to the requirement of the special users. This complicates the work of usability practitioners as well as academician that practices research usability when application are developed for the specific user needs. To overcome this issue, dimension chosen for the hearing-impaired are ensured to be align with the real need of the hearing-impaired mobile application. Besides literature studies, requirements for the hearing-impaired mobile application have been identified through interview conducted with hearing-impaired mobile application users that were recorded as video outputs and analyzed using Nvivo. Finally total of 6 out of 15 dimensions gathered are chosen for the proposed model and presented.

  7. Oral delivery of peptides and proteins using lipid-based drug delivery systems

    DEFF Research Database (Denmark)

    Li, Ping; Nielsen, Hanne Mørck; Müllertz, Anette

    2012-01-01

    INTRODUCTION: In order to successfully develop lipid-based drug delivery systems (DDS) for oral administration of peptides and proteins, it is important to gain an understanding of the colloid structures formed by these DDS, the mode of peptide and protein incorporation as well as the mechanism...... by which intestinal absorption of peptides and proteins is promoted. AREAS COVERED: The present paper reviews the literature on lipid-based DDS, employed for oral delivery of peptides and proteins and highlights the mechanisms by which the different lipid-based carriers are expected to overcome the two...... and proteins. EXPERT OPINION: Lipid-based DDS are safe and suitable for oral delivery of peptides and proteins. Significant progress has been made in this area with several technologies on clinical trials. However, a better understanding of the mechanism of action in vivo is needed in order to improve...

  8. Pharmacokinetic characteristics of formulated alendronate transdermal delivery systems in rats and humans.

    Science.gov (United States)

    Choi, Ahyoung; Gang, Hyesil; Whang, Jiae; Gwak, Hyesun

    2010-05-01

    The objective of this study was to examine the absorption of alendronate from formulated transdermal delivery systems in rats and humans. When alendronate was applied to rats by transdermal delivery systems (7.2 mg) and oral administration (30 mg/kg), a statistically significant difference was found in the amount remaining to be excreted at time t (Ae(t)) and the amount remaining to be excreted at time 0 (Ae(infinity)) (p transdermal delivery systems. There was a linear relationship (r(2) = 0.9854) between the drug loading dose and Ae(infinity). The Ae(infinity) values from the transdermal delivery system containing 6% caprylic acid (53.8 mg as alendronate) and an oral product (Fosamax), 70 mg as alendronate) in humans were 127.0 +/- 34.2 microg and 237.2 +/- 56.3 microg, respectively. The dose-adjusted relative Ae(infinity) ratio of the transdermal delivery system to oral product was calculated to be 69.7%. The long half-life of alendronate in the transdermal delivery system (50.6 +/- 6.4 h), compared to that of the oral product (3.5 +/- 1.1 h) could allow less-frequent dosing. In conclusion, this study showed that a transdermal delivery system containing 6% caprylic acid in PG could be a favorable alternative for alendronate administration.

  9. Pharmacokinetics of a 5-fluorouracil liposomal delivery system.

    OpenAIRE

    Simmons, S T; Sherwood, M B; Nichols, D A; Penne, R B; Sery, T; Spaeth, G L

    1988-01-01

    A liposomal delivery system was developed in an attempt to prolong ocular levels of 5-fluorouracil for glaucoma filtering surgery. The pharmacokinetics of the 5-fluorouracil liposomal delivery system were studied in normal pigmented rabbits with 5-fluorouracil labelled with carbon-14 (C-14). 14C 5-fluorouracil was incorporated into the liposomes at a concentration of 10 g/l and injected subconjunctivally in doses of 5 and 10 mg. Concentrations of 5-fluorouracil were assayed at 10 time interva...

  10. Barefooted Usability Evaluation: Addressing the Mindset, Resources and Competences

    OpenAIRE

    Bruun , Anders

    2011-01-01

    Part 1: Long and Short Papers; International audience; Lack of usability specialists, high resource requirements and developer mindsets are three considerable barriers for introducing usability engineering into software companies. This Ph.D. project explores the effect of letting software developers and end users apply usability engineering methods instead of a specialist, a solution which may reduce the barriers.

  11. Assessing Library Instruction through Web Usability and Vocabulary Studies

    Science.gov (United States)

    Castonguay, Remi

    2008-01-01

    Can we use the methods of Web usability testing to learn about library instruction? This article is among the first in the field trying to establish a link between usability and instruction. The author discusses useful insights that Web usability can bring to our pedagogy as well as to the efficiency of library instruction. The result of a Web…

  12. Mucoadhesive drug delivery systems

    Directory of Open Access Journals (Sweden)

    Rahamatullah Shaikh

    2011-01-01

    Full Text Available Mucoadhesion is commonly defined as the adhesion between two materials, at least one of which is a mucosal surface. Over the past few decades, mucosal drug delivery has received a great deal of attention. Mucoadhesive dosage forms may be designed to enable prolonged retention at the site of application, providing a controlled rate of drug release for improved therapeutic outcome. Application of dosage forms to mucosal surfaces may be of benefit to drug molecules not amenable to the oral route, such as those that undergo acid degradation or extensive first-pass metabolism. The mucoadhesive ability of a dosage form is dependent upon a variety of factors, including the nature of the mucosal tissue and the physicochemical properties of the polymeric formulation. This review article aims to provide an overview of the various aspects of mucoadhesion, mucoadhesive materials, factors affecting mucoadhesion, evaluating methods, and finally various mucoadhesive drug delivery systems (buccal, nasal, ocular, gastro, vaginal, and rectal.

  13. Cost-justifying usability an update for the internet age

    CERN Document Server

    Bias, Randolph G; Bias, Randolph G

    2005-01-01

    You just know that an improvement of the user interface will reap rewards, but how do you justify the expense and the labor and the time-guarantee a robust ROI!-ahead of time? How do you decide how much of an investment should be funded? And what is the best way to sell usability to others? In this completely revised and new edition, Randolph G. Bias (University of Texas at Austin, with 25 years' experience as a usability practitioner and manager) and Deborah J. Mayhew (internationally recognized usability consultant and author of two other seminal books including The Usability Enginee

  14. Nanocomposites chitosan/montmorillonite for drug delivery system

    International Nuclear Information System (INIS)

    Braga, Carla R. Costa; Barbosa, Rossemberg C.; Lima, Rosemary S. Cunha; Fook, Marcus V. Lia; Silva, Suedina M. Lima

    2009-01-01

    In drugs delivery system the incorporation of an inorganic nanophase in polymer matrix, i.e. production of an inorganic-organic nanocomposite is an attractive alternative to obtain a constant release rate for a prolonged time. This study was performed to obtain films of nanocomposites Chitosan/montmorillonite intercalation by the technique of solution in the proportions of 1:1, 5:1 and 10:1. The nanocomposites were characterized by infrared spectroscopy, X-ray diffraction and thermogravimetric analysis. The results indicated that the feasibility of obtaining films of nanocomposites exfoliate. Among the suggested applications for films developed in this study includes them use for drugs delivery system. (author)

  15. On the Concepts of Usability and Reusability of Learning Objects

    Directory of Open Access Journals (Sweden)

    Miguel-Angel Sicilia

    2003-10-01

    Full Text Available “Reusable learning objects” oriented towards increasing their potential reusability are required to satisfy concerns about their granularity and their independence of concrete contexts of use. Such requirements also entail that the definition of learning object “usability,” and the techniques required to carry out their “usability evaluation” must be substantially different from those commonly used to characterize and evaluate the usability of conventional educational applications. In this article, a specific characterization of the concept of learning object usability is discussed, which places emphasis on “reusability,” the key property of learning objects residing in repositories. The concept of learning object reusability is described as the possibility and adequacy for the object to be usable in prospective educational settings, so that usability and reusability are considered two interrelated – and in many cases conflicting – properties of learning objects. Following the proposed characterization of two characteristics or properties of learning objects, a method to evaluate usability of specific learning objects will be presented.

  16. Nano-scale gene delivery systems; current technology, obstacles, and future directions.

    Science.gov (United States)

    Garcia-Guerra, Antonio; Dunwell, Thomas L; Trigueros, Sonia

    2018-01-07

    Within the different applications of nanomedicine currently being developed, nano-gene delivery is appearing as an exciting new technique with the possibility to overcome recognised hurdles and fulfill several biological and medical needs. The central component of all delivery systems is the requirement for the delivery of genetic material into cells, and for them to eventually reside in the nucleus where their desired function will be exposed. However, genetic material does not passively enter cells; thus, a delivery system is necessary. The emerging field of nano-gene delivery exploits the use of new materials and the properties that arise at the nanometre-scale to produce delivery vectors that can effectively deliver genetic material into a variety of different types of cells. The novel physicochemical properties of the new delivery vectors can be used to address the current challenges existing in nucleic acid delivery in vitro and in vivo. While there is a growing interest in nanostructure-based gene delivery, the field is still in its infancy, and there is yet much to discover about nanostructures and their physicochemical properties in a biological context. We carry out an organized and focused search of bibliographic databases. Our results suggest that despite new breakthroughs in nanostructure synthesis and advanced characterization techniques, we still face many barriers in producing highly efficient and non-toxic delivery systems. In this review, we overview the types of systems currently used for clinical and biomedical research applications along with their advantages and disadvantages, as well as discussing barriers that arise from nano-scale interactions with biological material. In conclusion, we hope that by bringing the far reaching multidisciplinary nature of nano-gene delivery to light, new targeted nanotechnology-bases strategies are developed to overcome the major challenges covered in this review. Copyright© Bentham Science Publishers; For

  17. A Usability Study of Users’ Perceptions Toward a Multimedia Computer-Assisted Learning Tool for Neuroanatomy

    Science.gov (United States)

    Gould, Douglas J.; Terrell, Mark A.; Fleming, Jo

    2015-01-01

    This usability study evaluated users’ perceptions of a multimedia prototype for a new e-learning tool: Anatomy of the Central Nervous System: A Multimedia Course. Usability testing is a collection of formative evaluation methods that inform the developmental design of e-learning tools to maximize user acceptance, satisfaction, and adoption. Sixty-two study participants piloted the prototype and completed a usability questionnaire designed to measure two usability properties: program need and program applicability. Statistical analyses were used to test the hypothesis that the multimedia prototype was well designed and highly usable, it was perceived as: 1) highly needed across a spectrum of educational contexts, 2) highly applicable in supporting the pedagogical processes of teaching and learning neuroanatomy, and 3) was highly usable by all types of users. Three independent variables represented user differences: level of expertise (faculty vs. student), age, and gender. Analysis of the results supports the research hypotheses that the prototype was designed well for different types of users in various educational contexts and for supporting the pedagogy of neuroanatomy. In addition, the results suggest that the multimedia program will be most useful as a neuroanatomy review tool for health-professions students preparing for licensing or board exams. This study demonstrates the importance of integrating quality properties of usability with principles of human learning during the instructional design process for multimedia products. PMID:19177405

  18. Encapsulation systems for the delivery of hydrophilic nutraceuticals: Food application.

    Science.gov (United States)

    Aditya, N P; Espinosa, Yadira Gonzalez; Norton, Ian T

    2017-07-01

    Increased health risk associated with the sedentary life style is forcing the food manufacturers to look for food products with specific or general health benefits e.g. beverages enriched with nutraceuticals like catechin, curcumin rutin. Compounds like polyphenols, flavonoids, vitamins are the good choice of bioactive compounds that can be used to fortify the food products to enhance their functionality. However due to low stability and bioavailability of these bioactives (both hydrophobic and hydrophilic) within the heterogeneous food microstructure and in the Gastro Intestinal Tract (GIT), it becomes extremely difficult to pass on the real health benefits to the consumers. Recent developments in the application of nano-delivery systems for food product development is proving to be a game changer which has raised the expectations of the researchers, food manufacturers and consumers regarding possibility of enhancing the functionality of bioactives within the fortified food products. In this direction, nano/micro delivery systems using lipids, surfactants and other materials (carbohydrates, polymers, complexes, protein) have been fabricated to stabilize and enhance the biological activity of the bioactive compounds. In the present review, current status of the various delivery systems that are used for the delivery of hydrophilic bioactives and future prospects for using other delivery systems that have been not completely explored for the delivery of hydrophilic bioactives e.g. niosomes; bilosomes, cubosomes are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. A usability review of a model checker VIS for the verification of NPP I and C system safety software

    International Nuclear Information System (INIS)

    Son, H. S.; Kwon, K. C.

    2002-01-01

    This paper discusses the usability of a model checker VIS in the verification of safety software of NPP I and C systems. The software development environment exemplified in this paper is for PLC and ESF-CCS which are being developed in KNICS project. In this environment, STATEMATE is used in requirement analysis and design phases. PLC is expected to be implemented using C language and an assembly language because it has many interfaces with hardware like CPU, I/O devices, communication devices. ESF-CCS is supposed to be developed in terms of PLC programming languages which are defined in IEC 61131-3 standard. In this case, VIS proved to be very useful through the review. We are also able to expect greater usability of VIS if we further develop the techniques for code abstraction and automatic translation from code to verilog, which is the input of VIS

  20. Chitosan-based delivery systems for diclofenac delivery: preparation and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Dreve, Simina; Kacso, Irina; Bratu, Ioan; Indrea, Emil, E-mail: simina.dreve@itim-cj.r [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath, 400293 Cluj-Napoca (Romania)

    2009-08-01

    The preparation and characterization of novel materials for drug delivery has rapidly gained importance in development of innovative medicine. The paper concerns the uses of chitosan as an excipient in oral formulations and as a drug delivery vehicle for burnt painful injuries. The use of chitosan (CTS) as base in polyelectrolyte complex systems, to prepare liquid release systems as hydrogels and solid release systems as sponges is presented. In this paper the preparation of CTS hydrogels and sponges carrying diclofenac (DCF), as anti-inflammatory drug is reported. The immobilization of DCF in CTS is done by mixing the CTS hydrogel with the anti-inflammatory drug solutions. The concentration of anti-inflammatory drug in the CTS hydrogel generating the sponges was of 57 mg/l, 72 mg/l and 114 mg/l. The CTS sponges with anti-inflammatory drugs were prepared by freeze-drying at -610{sup 0}C and 0,09 atm. The characterization of the hydrogels and sponges was done by infrared spectra (FTIR) and ultraviolet-visible spectroscopy (UV-VIS). The results indicated the formation of CTS-DCF intermediates. The DCF molecules are forming temporary chelates in CTS hydrogels and sponges and they are compatible with skin or some of biological fluids with satisfactory results.

  1. Chitosan-based delivery systems for diclofenac delivery: preparation and characterization

    International Nuclear Information System (INIS)

    Dreve, Simina; Kacso, Irina; Bratu, Ioan; Indrea, Emil

    2009-01-01

    The preparation and characterization of novel materials for drug delivery has rapidly gained importance in development of innovative medicine. The paper concerns the uses of chitosan as an excipient in oral formulations and as a drug delivery vehicle for burnt painful injuries. The use of chitosan (CTS) as base in polyelectrolyte complex systems, to prepare liquid release systems as hydrogels and solid release systems as sponges is presented. In this paper the preparation of CTS hydrogels and sponges carrying diclofenac (DCF), as anti-inflammatory drug is reported. The immobilization of DCF in CTS is done by mixing the CTS hydrogel with the anti-inflammatory drug solutions. The concentration of anti-inflammatory drug in the CTS hydrogel generating the sponges was of 57 mg/l, 72 mg/l and 114 mg/l. The CTS sponges with anti-inflammatory drugs were prepared by freeze-drying at -610 0 C and 0,09 atm. The characterization of the hydrogels and sponges was done by infrared spectra (FTIR) and ultraviolet-visible spectroscopy (UV-VIS). The results indicated the formation of CTS-DCF intermediates. The DCF molecules are forming temporary chelates in CTS hydrogels and sponges and they are compatible with skin or some of biological fluids with satisfactory results.

  2. Microemulsions based transdermal drug delivery systems.

    Science.gov (United States)

    Vadlamudi, Harini C; Narendran, Hyndavi; Nagaswaram, Tejeswari; Yaga, Gowri; Thanniru, Jyotsna; Yalavarthi, Prasanna R

    2014-01-01

    Since the discovery of microemulsions by Jack H Schulman, there has been huge progress made in applying microemulsion systems in plethora of research and industrial process. Microemulsions are optically isotropic systems consisting of water, oil and amphiphile. These systems are beneficial due to their thermodynamic stability, optical clarity, ease of preparation, higher diffusion and absorption rates. Moreover, it has been reported that the ingredients of microemulsion can effectively overcome the diffusion barrier and penetrate through the stratum corneum of the skin. Hence it becomes promising for both transdermal and dermal drug delivery. However, low viscosity of microemulsion restrains its applicability in pharmaceutical industry. To overcome the above drawback, the low viscous microemulsions were added to viscous gel bases to potentiate its applications as topical drug delivery systems so that various drug related toxic effects and erratic drug absorption can be avoided. The present review deals with the microemulsions, various techniques involved in the development of organic nanoparticles. The review emphasized on microemulsion based systems such as hydrogels and organogels. The physicochemical characteristics, mechanical properties, rheological and stability principles involved in microemulsion based viscous gels were also explored.

  3. A brain-computer interface based cognitive training system for healthy elderly: a randomized control pilot study for usability and preliminary efficacy.

    Science.gov (United States)

    Lee, Tih-Shih; Goh, Siau Juinn Alexa; Quek, Shin Yi; Phillips, Rachel; Guan, Cuntai; Cheung, Yin Bun; Feng, Lei; Teng, Stephanie Sze Wei; Wang, Chuan Chu; Chin, Zheng Yang; Zhang, Haihong; Ng, Tze Pin; Lee, Jimmy; Keefe, Richard; Krishnan, K Ranga Rama

    2013-01-01

    Cognitive decline in aging is a pressing issue associated with significant healthcare costs and deterioration in quality of life. Previously, we reported the successful use of a novel brain-computer interface (BCI) training system in improving symptoms of attention deficit hyperactivity disorder. Here, we examine the feasibility of the BCI system with a new game that incorporates memory training in improving memory and attention in a pilot sample of healthy elderly. This study investigates the safety, usability and acceptability of our BCI system to elderly, and obtains an efficacy estimate to warrant a phase III trial. Thirty-one healthy elderly were randomized into intervention (n = 15) and waitlist control arms (n = 16). Intervention consisted of an 8-week training comprising 24 half-hour sessions. A usability and acceptability questionnaire was administered at the end of training. Safety was investigated by querying users about adverse events after every session. Efficacy of the system was measured by the change of total score from the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) before and after training. Feedback on the usability and acceptability questionnaire was positive. No adverse events were reported for all participants across all sessions. Though the median difference in the RBANS change scores between arms was not statistically significant, an effect size of 0.6SD was obtained, which reflects potential clinical utility according to Simon's randomized phase II trial design. Pooled data from both arms also showed that the median change in total scores pre and post-training was statistically significant (Mdn = 4.0; pattention (p = 0.039), and delayed memory (pattention in healthy elderly, and appears to be safe, user-friendly and acceptable to senior users. Given the efficacy signal, a phase III trial is warranted. ClinicalTrials.gov NCT01661894.

  4. Excimer laser beam delivery systems for medical applications

    Science.gov (United States)

    Kubo, Uichi; Hashishin, Yuichi; Okada, Kazuyuki; Tanaka, Hiroyuki

    1993-05-01

    We have been doing the basic experiments of UV laser beams and biotissue interaction with both KrF and XeCl lasers. However, the conventional optical fiber can not be available for power UV beams. So we have been investigating about UV power beam delivery systems. These experiments carry on with the same elements doped quartz fibers and the hollow tube. The doped elements are OH ion, chlorine and fluorine. In our latest work, we have tried ArF excimer laser and biotissue interactions, and the beam delivery experiments. From our experimental results, we found that the ArF laser beam has high incision ability for hard biotissue. For example, in the case of the cow's bone incision, the incision depth by ArF laser was ca.15 times of KrF laser. Therefore, ArF laser would be expected to harden biotissue therapy as non-thermal method. However, its beam delivery is difficult to work in this time. We will develop ArF laser beam delivery systems.

  5. Evaluation of Roadmap to Achieve Energy Delivery Systems Cybersecurity

    Energy Technology Data Exchange (ETDEWEB)

    Chavez, Adrian R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-10-01

    The Department of Energy/Office of Electricity Delivery and Energy Reliability (DOE/OE) Cybersecurity for Energy Delivery Systems (CEDS) program is currently evaluating the Roadmap to Achieve Energy Delivery Systems Cybersecurity document that sets a vision and outlines a set of milestones. The milestones are divided into five strategic focus areas that include: 1. Build a Culture of Security; 2. Assess and Monitor Risk; 3. Develop and Implement New Protective Measures to Reduce Risk; 4. Manage Incidents; and 5. Sustain Security Improvements. The most current version of the roadmap was last updated in September of 2016. Sandia National Laboratories (SNL) has been tasked with revisiting the roadmap to update the current state of energy delivery systems cybersecurity protections. SNL is currently working with previous and current partners to provide feedback on which of the roadmap milestones have been met and to identify any preexisting or new gaps that are not addressed by the roadmap. The specific focus areas SNL was asked to evaluate are: 1. Develop and Implement New Protective Measures to Reduce Risk and 2. Sustain Security Improvements. SNL has formed an Industry Advisory Board (IAB) to assist in answering these questions. The IAB consists of previous partners on past CEDS funded efforts as well as new collaborators that have unique insights into the current state of cybersecurity within energy delivery systems. The IAB includes asset owners, utilities and vendors of control systems. SNL will continue to maintain regular communications with the IAB to provide various perspectives on potential future updates to further improve the breadth of cybersecurity coverage of the roadmap.

  6. Usability Evaluation of the Spatial OLAP Visualization and Analysis Tool (SOVAT).

    Science.gov (United States)

    Scotch, Matthew; Parmanto, Bambang; Monaco, Valerie

    2007-02-01

    Increasingly sophisticated technologies, such as On-Line Analytical Processing (OLAP) and Geospatial Information Systems (GIS), are being leveraged for conducting community health assessments (CHA). Little is known about the usability of OLAP and GIS interfaces with respect to CHA. We conducted an iterative usability evaluation of the Spatial OLAP Visualization and Analysis Tool (SOVAT), a software application that combines OLAP and GIS. A total of nine graduate students and six community health researchers were asked to think-aloud while completing five CHA questions using SOVAT. The sessions were analyzed after every three participants and changes to the interface were made based on the findings. Measures included elapsed time, answers provided, erroneous actions, and satisfaction. Traditional OLAP interface features were poorly understood by participants and combined OLAP-GIS features needed to be better emphasized. The results suggest that the changes made to the SOVAT interface resulted in increases in both usability and user satisfaction.

  7. Nanoparticle-based drug delivery systems: promising approaches against infections

    International Nuclear Information System (INIS)

    Ranghar, Shweta; Sirohi, Parul; Verma, Pritam; Agarwal, Vishnu

    2014-01-01

    Despite the fact that many new drugs and technologies have been developed to combat the infectious diseases, these have continued to be global health challenges. The use of conventional antimicrobial agents against these infections is always associated with problems such as the development of multiple drug resistance and adverse side effects. In addition, the inefficient traditional drug delivery system results in inadequate therapeutic index, low bioavailability of drugs and many other limitations. In this regard, antimicrobial nanoparticles and nanosized drug delivery carriers have emerged as potent effective agents against the infections. Nanoparticles have unique properties owing to their ultra small and controllable size such as high surface area, enhanced reactivity, and functionalizable structure. This review focused on different classes of antimicrobial nanoparticles, including metal, metal oxide and others along with their mechanism of action and their potential use against the infections. The review also focused on the development of nanoparticle systems for antimicrobial drug delivery and use of these systems for delivery of various antimicrobial agents, giving an overview about modern nanoparticle based therapeutic strategies against the infections. (author)

  8. Nanoparticle-based drug delivery systems: promising approaches against infections

    Energy Technology Data Exchange (ETDEWEB)

    Ranghar, Shweta; Sirohi, Parul [Department of Applied Mechanics, Motilal Nehru National Institute of Technology, Allahabad (India); Verma, Pritam; Agarwal, Vishnu [Department of Biotechnology, Motilal Nehru National Institute of Technology, Allahabad (India)

    2014-03-15

    Despite the fact that many new drugs and technologies have been developed to combat the infectious diseases, these have continued to be global health challenges. The use of conventional antimicrobial agents against these infections is always associated with problems such as the development of multiple drug resistance and adverse side effects. In addition, the inefficient traditional drug delivery system results in inadequate therapeutic index, low bioavailability of drugs and many other limitations. In this regard, antimicrobial nanoparticles and nanosized drug delivery carriers have emerged as potent effective agents against the infections. Nanoparticles have unique properties owing to their ultra small and controllable size such as high surface area, enhanced reactivity, and functionalizable structure. This review focused on different classes of antimicrobial nanoparticles, including metal, metal oxide and others along with their mechanism of action and their potential use against the infections. The review also focused on the development of nanoparticle systems for antimicrobial drug delivery and use of these systems for delivery of various antimicrobial agents, giving an overview about modern nanoparticle based therapeutic strategies against the infections. (author)

  9. Delivery Systems for Biopharmaceuticals. Part I: Nanoparticles and Microparticles.

    Science.gov (United States)

    Silva, Ana C; Lopes, Carla M; Lobo, José M S; Amaral, Maria H

    2015-01-01

    Pharmaceutical biotechnology has been showing therapeutic success never achieved with conventional drug molecules. Therefore, biopharmaceutical products are currently well-established in clinic and the development of new ones is expected. These products comprise mainly therapeutic proteins, although nucleic acids and cells are also included. However, according to their sensitive molecular structures, the efficient delivery of biopharmaceuticals is challenging. Several delivery systems (e.g. microparticles and nanoparticles) composed of different materials (e.g. polymers and lipids) have been explored and demonstrated excellent outcomes, such as: high cellular transfection efficiency for nucleic acids, cell targeting, increased proteins and peptides bioavailability, improved immune response in vaccination, and viability maintenance of microencapsulated cells. Nonetheless, important issues need to be addressed before they reach clinics. For example, more in vivo studies in animals, accessing the toxicity potential and predicting in vivo failure of these delivery systems are required. This is the Part I of two review articles, which presents the state of the art of delivery systems for biopharmaceuticals. Part I deals with microparticles and polymeric and lipid nanoparticles.

  10. Oral delivery of peptides and proteins using lipid-based drug delivery systems.

    Science.gov (United States)

    Li, Ping; Nielsen, Hanne Mørck; Müllertz, Anette

    2012-10-01

    In order to successfully develop lipid-based drug delivery systems (DDS) for oral administration of peptides and proteins, it is important to gain an understanding of the colloid structures formed by these DDS, the mode of peptide and protein incorporation as well as the mechanism by which intestinal absorption of peptides and proteins is promoted. The present paper reviews the literature on lipid-based DDS, employed for oral delivery of peptides and proteins and highlights the mechanisms by which the different lipid-based carriers are expected to overcome the two most important barriers (extensive enzymatic degradation and poor transmucosal permeability). This paper also gives a clear-cut idea about advantages and drawbacks of using different lipidic colloidal carriers ((micro)emulsions, solid lipid core particles and liposomes) for oral delivery of peptides and proteins. Lipid-based DDS are safe and suitable for oral delivery of peptides and proteins. Significant progress has been made in this area with several technologies on clinical trials. However, a better understanding of the mechanism of action in vivo is needed in order to improve the design and development of lipid-based DDS with the desired bioavailability and therapeutic profile.

  11. Characterization of particulate drug delivery systems for oral delivery of Peptide and protein drugs.

    Science.gov (United States)

    Christophersen, Philip Carsten; Fano, Mathias; Saaby, Lasse; Yang, Mingshi; Nielsen, Hanne Mørck; Mu, Huiling

    2015-01-01

    Oral drug delivery is a preferred route because of good patient compliance. However, most peptide/ protein drugs are delivered via parenteral routes because of the absorption barriers in the gastrointestinal (GI) tract such as enzymatic degradation by proteases and low permeability acrossthe biological membranes. To overcome these barriers, different formulation strategies for oral delivery of biomacromolecules have been proposed, including lipid based formulations and polymer-based particulate drug delivery systems (DDS). The aim of this review is to summarize the existing knowledge about oral delivery of peptide/protein drugs and to provide an overview of formulationand characterization strategies. For a better understanding of the challenges in oral delivery of peptide/protein drugs, the composition of GI fluids and the digestion processes of different kinds of excipients in the GI tract are summarized. Additionally, the paper provides an overview of recent studies on characterization of solid drug carriers for peptide/protein drugs, drug distribution in particles, drug release and stability in simulated GI fluids, as well as the absorption of peptide/protein drugs in cell-based models. The use of biorelevant media when applicable can increase the knowledge about the quality of DDS for oral protein delivery. Hopefully, the knowledge provided in this review will aid the establishment of improved biorelevant models capable of forecasting the performance of particulate DDS for oral peptide/protein delivery.

  12. Nonviral Delivery Systems For Cancer Gene Therapy: Strategies And Challenges.

    Science.gov (United States)

    Shim, Gayong; Kim, Dongyoon; Le, Quoc-Viet; Park, Gyu Thae; Kwon, Taekhyun; Oh, Yu-Kyoung

    2018-01-19

    Gene therapy has been receiving widespread attention due to its unique advantage in regulating the expression of specific target genes. In the field of cancer gene therapy, modulation of gene expression has been shown to decrease oncogenic factors in cancer cells or increase immune responses against cancer. Due to the macromolecular size and highly negative physicochemical features of plasmid DNA, efficient delivery systems are an essential ingredient for successful gene therapy. To date, a variety of nanostructures and materials have been studied as nonviral gene delivery systems. In this review, we will cover nonviral delivery strategies for cancer gene therapy, with a focus on target cancer genes and delivery materials. Moreover, we will address current challenges and perspectives for nonviral delivery-based cancer gene therapeutics. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  13. Relationship Between Visual, Hearing and Memory Disabilities and Hand Grip Strength and the Systems Usability Available to the Elderly Living in Nursing Homes in Kerman, Iran

    Directory of Open Access Journals (Sweden)

    Vafa Feyzi

    2017-03-01

    Conclusion With increasing age, the disabilities of the elderly get intensified and their ability to use systems decrease. Thus, it is necessary to prevent their loss of abilities in order to enhance their systems usability.

  14. Gene delivery systems by the combination of lipid bubbles and ultrasound.

    Science.gov (United States)

    Negishi, Yoichi; Endo-Takahashi, Yoko; Maruyama, Kazuo

    2016-11-28

    Gene therapy is promising for the treatment of many diseases including cancers and genetic diseases. From the viewpoint of safety, ultrasound (US)-mediated gene delivery with nano/ microbubbles was recently developed as a novel non-viral vector system. US-mediated gene delivery using nano/microbubbles are able to produce transient changes in the permeability of the cell membrane after US-induced cavitation while reducing cellular damage and enables the tissue-specific or the site-specific intracellular delivery of gene both in vitro and in vivo. We have recently developed novel lipid nanobubbles (Lipid Bubbles). These nanobubbles can also be used to enhance the efficacy of the US-mediated genes (plasmid DNA, siRNA, and miRNA etc.) delivery. In this review, we describe US-mediated delivery systems combined with nano/microbubbles and discuss their feasibility as non-viral vector systems.

  15. Relationship between trust and usability in virtual environments: An ongoing study

    NARCIS (Netherlands)

    Salanitri, Davide; Hare, Chrisminder; Borsci, Simone; Lawson, Glyn; Sharples, Sarah; Water Fi Eld, Brian; Kurosu, Masaaki

    2015-01-01

    Usability and trust have been observed to be related in several domains including web retail, information systems, and e-health. Trust in technology reflects beliefs about the attributes of a technology. Research has shown that trust is a key factor for the success of different systems – e.g.,

  16. Evidence-based Heuristics for Evaluating Demands on eHealth Literacy and Usability in a Mobile Consumer Health Application.

    Science.gov (United States)

    Monkman, Helen; Griffith, Janessa; Kushniruk, Andre W

    2015-01-01

    Heuristic evaluations have proven to be valuable for identifying usability issues in systems. Commonly used sets of heuritics exist; however, they may not always be the most suitable, given the specific goal of the analysis. One such example is seeking to evaluate the demands on eHealth literacy and usability of consumer health information systems. In this study, eight essential heuristics and three optional heuristics subsumed from the evidence on eHealth/health literacy and usability were tested for their utility in assessing a mobile blood pressure tracking application (app). This evaluation revealed a variety of ways the design of the app could both benefit and impede users with limited eHealth literacy. This study demonstrated the utility of a low-cost, single evaluation approach for identifying both eHealth literacy and usability issues based on existing evidence in the literature.

  17. Usability of a patient education and motivation tool using heuristic evaluation.

    Science.gov (United States)

    Joshi, Ashish; Arora, Mohit; Dai, Liwei; Price, Kathleen; Vizer, Lisa; Sears, Andrew

    2009-11-06

    Computer-mediated educational applications can provide a self-paced, interactive environment to deliver educational content to individuals about their health condition. These programs have been used to deliver health-related information about a variety of topics, including breast cancer screening, asthma management, and injury prevention. We have designed the Patient Education and Motivation Tool (PEMT), an interactive computer-based educational program based on behavioral, cognitive, and humanistic learning theories. The tool is designed to educate users and has three key components: screening, learning, and evaluation. The objective of this tutorial is to illustrate a heuristic evaluation using a computer-based patient education program (PEMT) as a case study. The aims were to improve the usability of PEMT through heuristic evaluation of the interface; to report the results of these usability evaluations; to make changes based on the findings of the usability experts; and to describe the benefits and limitations of applying usability evaluations to PEMT. PEMT was evaluated by three usability experts using Nielsen's usability heuristics while reviewing the interface to produce a list of heuristic violations with severity ratings. The violations were sorted by heuristic and ordered from most to least severe within each heuristic. A total of 127 violations were identified with a median severity of 3 (range 0 to 4 with 0 = no problem to 4 = catastrophic problem). Results showed 13 violations for visibility (median severity = 2), 38 violations for match between system and real world (median severity = 2), 6 violations for user control and freedom (median severity = 3), 34 violations for consistency and standards (median severity = 2), 11 violations for error severity (median severity = 3), 1 violation for recognition and control (median severity = 3), 7 violations for flexibility and efficiency (median severity = 2), 9 violations for aesthetic and minimalist design

  18. Empirical studies on usability of mHealth apps: a systematic literature review.

    Science.gov (United States)

    Zapata, Belén Cruz; Fernández-Alemán, José Luis; Idri, Ali; Toval, Ambrosio

    2015-02-01

    The release of smartphones and tablets, which offer more advanced communication and computing capabilities, has led to the strong emergence of mHealth on the market. mHealth systems are being used to improve patients' lives and their health, in addition to facilitating communication between doctors and patients. Researchers are now proposing mHealth applications for many health conditions such as dementia, autism, dysarthria, Parkinson's disease, and so on. Usability becomes a key factor in the adoption of these applications, which are often used by people who have problems when using mobile devices and who have a limited experience of technology. The aim of this paper is to investigate the empirical usability evaluation processes described in a total of 22 selected studies related to mHealth applications by means of a Systematic Literature Review. Our results show that the empirical evaluation methods employed as regards usability could be improved by the adoption of automated mechanisms. The evaluation processes should also be revised to combine more than one method. This paper will help researchers and developers to create more usable applications. Our study demonstrates the importance of adapting health applications to users' need.

  19. From Usability Testing to Clinical Simulations: Bringing Context into the Design and Evaluation of Usable and Safe Health Information Technologies. Contribution of the IMIA Human Factors Engineering for Healthcare Informatics Working Group.

    Science.gov (United States)

    Kushniruk, A; Nohr, C; Jensen, S; Borycki, E M

    2013-01-01

    The objective of this paper is to explore human factors approaches to understanding the use of health information technology (HIT) by extending usability engineering approaches to include analysis of the impact of clinical context through use of clinical simulations. Methods discussed are considered on a continuum from traditional laboratory-based usability testing to clinical simulations. Clinical simulations can be conducted in a simulation laboratory and they can also be conducted in real-world settings. The clinical simulation approach attempts to bring the dimension of clinical context into stronger focus. This involves testing of systems with representative users doing representative tasks, in representative settings/environments. Application of methods where realistic clinical scenarios are used to drive the study of users interacting with systems under realistic conditions and settings can lead to identification of problems and issues with systems that may not be detected using traditional usability engineering methods. In conducting such studies, careful consideration is needed in creating ecologically valid test scenarios. The evidence obtained from such evaluation can be used to improve both the usability and safety of HIT. In addition, recent work has shown that clinical simulations, in particular those conducted in-situ, can lead to considerable benefits when compared to the costs of running such studies. In order to bring context of use into the testing of HIT, clinical simulation, involving observing representative users carrying out tasks in representative settings, holds considerable promise.

  20. Nanoparticulate systems for nucleic acid delivery

    NARCIS (Netherlands)

    Varkouhi, A.K.

    2011-01-01

    Development of carrier systems with controllable physicochemical and delivery properties has opened up the possibility of nanomedicines containing nucleic acids. In the last decades, much effort has been dedicated to two exciting approaches in biomedicine, namely gene and RNA interference

  1. Adamantane in Drug Delivery Systems and Surface Recognition.

    Science.gov (United States)

    Štimac, Adela; Šekutor, Marina; Mlinarić-Majerski, Kata; Frkanec, Leo; Frkanec, Ruža

    2017-02-16

    The adamantane moiety is widely applied in design and synthesis of new drug delivery systems and in surface recognition studies. This review focuses on liposomes, cyclodextrins, and dendrimers based on or incorporating adamantane derivatives. Our recent concept of adamantane as an anchor in the lipid bilayer of liposomes has promising applications in the field of targeted drug delivery and surface recognition. The results reported here encourage the development of novel adamantane-based structures and self-assembled supramolecular systems for basic chemical investigations as well as for biomedical application.

  2. Adamantane in Drug Delivery Systems and Surface Recognition

    Directory of Open Access Journals (Sweden)

    Adela Štimac

    2017-02-01

    Full Text Available The adamantane moiety is widely applied in design and synthesis of new drug delivery systems and in surface recognition studies. This review focuses on liposomes, cyclodextrins, and dendrimers based on or incorporating adamantane derivatives. Our recent concept of adamantane as an anchor in the lipid bilayer of liposomes has promising applications in the field of targeted drug delivery and surface recognition. The results reported here encourage the development of novel adamantane-based structures and self-assembled supramolecular systems for basic chemical investigations as well as for biomedical application.

  3. Usability testing of a mobile robotic system for in-home telerehabilitation.

    Science.gov (United States)

    Boissy, Patrick; Brière, Simon; Corriveau, Hélène; Grant, Andrew; Lauria, Michel; Michaud, François

    2011-01-01

    Mobile robots designed to enhance telepresence in the support of telehealth services are being considered for numerous applications. TELEROBOT is a teleoperated mobile robotic platform equipped with videoconferencingcapabilities and designed to be used in a home environment to. In this study, learnability of the system's teleoperation interface and controls was evaluated with ten rehabilitation professionals during four training sessions in a laboratory environment and in an unknown home environment while performing the execution of a standardized evaluation protocol typically used in home care. Results show that the novice teleoperators' performances on two of the four metrics used (number of command and total time) improved significantly across training sessions (ANOVAS, phome environment during navigation tasks (r=0,77 and 0,60). With only 4 hours of training, rehabilitation professionals were able learn to teleoperate successfully TELEROBOT. However teleoperation performances remained significantly less efficient then those of an expert. Under the home task condition (navigating the home environment from one point to the other as fast as possible) this translated to completion time between 350 seconds (best performance) and 850 seconds (worse performance). Improvements in other usability aspects of the system will be needed to meet the requirements of in-home telerehabilitation.

  4. LOGISTIC SYSTEM OF LOAD DELIVERY AND QUALITY OF ITS OPERATION

    Directory of Open Access Journals (Sweden)

    O. G. Drozdovskaya

    2006-01-01

    Full Text Available The paper considers an opportunity for obtaining a competitive advantage by a transport and dispatch service company in the market of transport services while establishing a logistic system of load delivery. A model of delivery system, an universal scheme of system designing for every specific case are presented and also indices for evaluation of its operational quality are proposed in the paper.

  5. Advances in the Applications of Polyhydroxyalkanoate Nanoparticles for Novel Drug Delivery System

    Directory of Open Access Journals (Sweden)

    Anupama Shrivastav

    2013-01-01

    Full Text Available Drug delivery technology is emerging as an interdisciplinary science aimed at improving human health. The controlled delivery of pharmacologically active agents to the specific site of action at the therapeutically optimal rate and dose regimen has been a major goal in designing drug delivery systems. Over the past few decades, there has been considerable interest in developing biodegradable drug carriers as effective drug delivery systems. Polymeric materials from natural sources play an important role in controlled release of drug at a particular site. Polyhydroxyalkanoates, due to their origin from natural sources, are given attention as candidates for drug delivery materials. Biodegradable and biocompatible polyhydroxyalkanoates are linear polyesters produced by microorganisms under unbalanced growth conditions, which have emerged as potential polymers for use as biomedical materials for drug delivery due to their unique physiochemical and mechanical properties. This review summarizes many of the key findings in the applications of polyhydroxyalkanoates and polyhydroxyalkanoate nanoparticles for drug delivery system.

  6. Distance Learning Delivery Systems: Instructional Options.

    Science.gov (United States)

    Steele, Ray L.

    1993-01-01

    Discusses the availability of satellite and cable programing to provide distance education opportunities in school districts. Various delivery systems are described, including telephones with speakers, personal computers, and satellite dishes; and a sidebar provides a directory of distance learning opportunities, including telecommunications…

  7. Nanoparticulate delivery systems for antiviral drugs.

    Science.gov (United States)

    Lembo, David; Cavalli, Roberta

    2010-01-01

    Nanomedicine opens new therapeutic avenues for attacking viral diseases and for improving treatment success rates. Nanoparticulate-based systems might change the release kinetics of antivirals, increase their bioavailability, improve their efficacy, restrict adverse drug side effects and reduce treatment costs. Moreover, they could permit the delivery of antiviral drugs to specific target sites and viral reservoirs in the body. These features are particularly relevant in viral diseases where high drug doses are needed, drugs are expensive and the success of a therapy is associated with a patient's adherence to the administration protocol. This review presents the current status in the emerging area of nanoparticulate delivery systems in antiviral therapy, providing their definition and description, and highlighting some peculiar features. The paper closes with a discussion on the future challenges that must be addressed before the potential of nanotechnology can be translated into safe and effective antiviral formulations for clinical use.

  8. Non-viral Nucleic Acid Delivery Strategies to the Central Nervous System

    Directory of Open Access Journals (Sweden)

    James-Kevin Tan

    2016-11-01

    Full Text Available With an increased prevalence and understanding of central nervous system injuries and neurological disorders, nucleic acid therapies are gaining promise as a way to regenerate lost neurons or halt disease progression. While more viral vectors have been used clinically as tools for gene delivery, non-viral vectors are gaining interest due to lower safety concerns and the ability to deliver all types of nucleic acids. Nevertheless, there are still a number of barriers to nucleic acid delivery. In this focused review, we explore the in vivo challenges hindering non-viral nucleic acid delivery to the central nervous system and the strategies and vehicles used to overcome them. Advantages and disadvantages of different routes of administration including: systemic injection, cerebrospinal fluid injection, intraparenchymal injection, and peripheral administration are discussed. Non-viral vehicles and treatment strategies that have overcome delivery barriers and demonstrated in vivo gene transfer to the central nervous system are presented. These approaches can be used as guidelines in developing synthetic gene delivery vectors for central nervous system applications and will ultimately bring non-viral vectors closer to clinical application.

  9. Post-deployment usability evaluation of a radiology workstation

    NARCIS (Netherlands)

    Jorritsma, Wiard; Cnossen, Fokie; Dierckx, Rudi A.; Oudkerk, Matthijs; Van Ooijen, Peter M. A.

    Objectives: To determine the number, nature and severity of usability issues radiologists encounter while using a commercially available radiology workstation in clinical practice, and to assess how well the results of a pre-deployment usability evaluation of this workstation generalize to clinical

  10. How to Reach Evidence-Based Usability Evaluation Methods

    NARCIS (Netherlands)

    Marcilly, Romaric; Peute, Linda

    2017-01-01

    This paper discusses how and why to build evidence-based knowledge on usability evaluation methods. At each step of building evidence, requisites and difficulties to achieve it are highlighted. Specifically, the paper presents how usability evaluation studies should be designed to allow capitalizing

  11. Integrating Visual Mnemonics and Input Feedback With Passphrases to Improve the Usability and Security of Digital Authentication.

    Science.gov (United States)

    Juang, Kevin; Greenstein, Joel

    2018-04-01

    We developed a new authentication system based on passphrases instead of passwords. Our new system incorporates a user-generated mnemonic picture displayed during login, definition tooltips, error correction to reduce typographical errors, a decoy-based input masking technique, and random passphrase generation using either a specialized wordlist or a sentence template. Passphrases exhibit a greater level of security than traditional passwords, but their wider adoption has been hindered by human factors issues. Our assertion is that the added features of our system work particularly well with passphrases and help address these shortcomings. We conducted a study to evaluate our new system with a customized 1,450-word list and our new system with a 6-word sentence structure against the control conditions of a user-created passphrase of at least 24 characters and a system-generated passphrase using a 10,326-word list. Fifty participants completed two sessions so that we could measure the usability and security of the authentication schemes. With the new system conditions, memorability was improved, and security was equivalent to or better than the control conditions. Usability and overall ratings also favored the new system conditions over the control conditions. Our research presents a new authentication system using innovative techniques that improve on the usability and security of existing password and passphrase authentication systems. In computer security, drastic changes should never happen overnight, but we recommend that our contributions be incorporated into current authentication systems to help facilitate a transition from passwords to usable passphrases.

  12. Web usability testing with a Hispanic medically underserved population.

    Science.gov (United States)

    Moore, Mary; Bias, Randolph G; Prentice, Katherine; Fletcher, Robin; Vaughn, Terry

    2009-04-01

    Skilled website developers value usability testing to assure user needs are met. When the target audience differs substantially from the developers, it becomes essential to tailor both design and evaluation methods. In this study, researchers carried out a multifaceted usability evaluation of a website (Healthy Texas) designed for Hispanic audiences with lower computer literacy and lower health literacy. METHODS INCLUDED: (1) heuristic evaluation by a usability engineer, (2) remote end-user testing using WebEx software; and (3) face-to-face testing in a community center where use of the website was likely. Researchers found standard usability testing methods needed to be modified to provide interpreters, increased flexibility for time on task, presence of a trusted intermediary such as a librarian, and accommodation for family members who accompanied participants. Participants offered recommendations for website redesign, including simplified language, engaging and relevant graphics, culturally relevant examples, and clear navigation. User-centered design is especially important when website developers are not representative of the target audience. Failure to conduct appropriate usability testing with a representative audience can substantially reduce use and value of the website. This thorough course of usability testing identified improvements that benefit all users but become crucial when trying to reach an underserved audience.

  13. A brain-computer interface based cognitive training system for healthy elderly: a randomized control pilot study for usability and preliminary efficacy.

    Directory of Open Access Journals (Sweden)

    Tih-Shih Lee

    Full Text Available Cognitive decline in aging is a pressing issue associated with significant healthcare costs and deterioration in quality of life. Previously, we reported the successful use of a novel brain-computer interface (BCI training system in improving symptoms of attention deficit hyperactivity disorder. Here, we examine the feasibility of the BCI system with a new game that incorporates memory training in improving memory and attention in a pilot sample of healthy elderly. This study investigates the safety, usability and acceptability of our BCI system to elderly, and obtains an efficacy estimate to warrant a phase III trial. Thirty-one healthy elderly were randomized into intervention (n = 15 and waitlist control arms (n = 16. Intervention consisted of an 8-week training comprising 24 half-hour sessions. A usability and acceptability questionnaire was administered at the end of training. Safety was investigated by querying users about adverse events after every session. Efficacy of the system was measured by the change of total score from the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS before and after training. Feedback on the usability and acceptability questionnaire was positive. No adverse events were reported for all participants across all sessions. Though the median difference in the RBANS change scores between arms was not statistically significant, an effect size of 0.6SD was obtained, which reflects potential clinical utility according to Simon's randomized phase II trial design. Pooled data from both arms also showed that the median change in total scores pre and post-training was statistically significant (Mdn = 4.0; p<0.001. Specifically, there were significant improvements in immediate memory (p = 0.038, visuospatial/constructional (p = 0.014, attention (p = 0.039, and delayed memory (p<0.001 scores. Our BCI-based system shows promise in improving memory and attention in healthy

  14. Software Build and Delivery Systems

    Energy Technology Data Exchange (ETDEWEB)

    Robey, Robert W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-07-10

    This presentation deals with the hierarchy of software build and delivery systems. One of the goals is to maximize the success rate of new users and developers when first trying your software. First impressions are important. Early successes are important. This also reduces critical documentation costs. This is a presentation focused on computer science and goes into detail about code documentation.

  15. Next Gen One Portal Usability Evaluation

    Science.gov (United States)

    Cross, E. V., III; Perera, J. S.; Hanson, A. M.; English, K.; Vu, L.; Amonette, W.

    2018-01-01

    Each exercise device on the International Space Station (ISS) has a unique, customized software system interface with unique layouts / hierarchy, and operational principles that require significant crew training. Furthermore, the software programs are not adaptable and provide no real-time feedback or motivation to enhance the exercise experience and/or prevent injuries. Additionally, the graphical user interfaces (GUI) of these systems present information through multiple layers resulting in difficulty navigating to the desired screens and functions. These limitations of current exercise device GUI's lead to increased crew time spent on initiating, loading, performing exercises, logging data and exiting the system. To address these limitations a Next Generation One Portal (NextGen One Portal) Crew Countermeasure System (CMS) was developed, which utilizes the latest industry guidelines in GUI designs to provide an intuitive ease of use approach (i.e., 80% of the functionality gained within 5-10 minutes of initial use without/limited formal training required). This is accomplished by providing a consistent interface using common software to reduce crew training, increase efficiency & user satisfaction while also reducing development & maintenance costs. Results from the usability evaluations showed the NextGen One Portal UI having greater efficiency, learnability, memorability, usability and overall user experience than the current Advanced Resistive Exercise Device (ARED) UI used by astronauts on ISS. Specifically, the design of the One-Portal UI as an app interface similar to those found on the Apple and Google's App Store, assisted many of the participants in grasping the concepts of the interface with minimum training. Although the NextGen One-Portal UI was shown to be an overall better interface, observations by the test facilitators noted specific exercise tasks appeared to have a significant impact on the NextGen One-Portal UI efficiency. Future updates to

  16. Efficient systemic DNA delivery to the tumor by self-assembled nanoparticle

    Science.gov (United States)

    Tang, Hailin; Xie, Xinhua; Guo, Jiaoli; Wei, Weidong; Wu, Minqing; Liu, Peng; Kong, Yanan; Yang, Lu; Hung, Mien-Chie; Xie, Xiaoming

    2014-01-01

    There are few delivery agents that could deliver gene with high efficiency and low toxicity, especially for animal experiments. Therefore, creating vectors with good delivery efficiency and safety profile is a meaningful work. We have developed a self-assembled gene delivery system (XM001), which can more efficiently deliver DNA to multiple cell lines and breast tumor, as compared to commercial delivery agents. In addition, systemically administrated XM001-BikDD (BikDD is a mutant form of proapoptotic gene Bik) significantly inhibited the growth of human breast cancer cells and prolonged the life span in implanted nude mice. This study demonstrates that XM001 is an efficient and widespread transfection agent, which could be a promising tumor delivery vector for cancer targeted therapy.

  17. Usability Assessment of International Office Website of Diponegoro University With Scenario Based Usability Evaluation Method and Wammi Method

    OpenAIRE

    Ratna Purwaningsih; Ikhsan Yenifi

    2015-01-01

    Website development needs to pay attention to usability aspect which consist of four factors: efficiency, effectiveness, satisfactions and error rate. The website of International Office of Diponegoro University provides academic information for Indonesian students and foreign students. The website still has some problem, especially on searching certain information. This research aims to evaluate the design of the existing website and measures the usability. A well-designed website will help ...

  18. Post-deployment usability evaluation of a radiology workstation

    NARCIS (Netherlands)

    Jorritsma, Wiard; Cnossen, Fokie; Dierckx, Rudi; Oudkerk, Matthijs; van Ooijen, Peter

    2015-01-01

    Objective To evaluate the usability of a radiology workstation after deployment in a hospital. Significance In radiology, it is difficult to perform valid pre-deployment usability evaluations due to the heterogeneity of the user group, the complexity of the radiological workflow, and the complexity

  19. Usability Plans and Schemes for Low Fidelity Prototypes

    DEFF Research Database (Denmark)

    Schultz, Nette; Kirk Sørensen, Jannick; Sørensen, Lene

    2006-01-01

    Internal report of WP1 task 4 activities from August 2006 to December 2006. This report describes the setup of a usability evaluation framework for evaluating core MAGNET concepts in terms of usability. Initially, these core concepts are identified and modes of operation involving...

  20. Usability evaluation of a locomotor therapy device considering different strategies

    Directory of Open Access Journals (Sweden)

    Langthaler Sonja

    2016-09-01

    Full Text Available Usability of medical devices is one of the main determining factors in preventing use errors in treatment and strongly correlates to patient safety and quality of treatment. This thesis demonstrates the usability testing and evaluation of a prototype for locomotor therapy of infants. Therefore, based on the normative requirements of the EN 62366, a concept combined of evaluation procedures and assessing methods was created to enable extensive testing and analysis of the different aspects of usability. On the basis of gathered information weak points were identified and appropriate measures were presented to increase the usability and operating safety of the locomotor prototype. The overall outcome showed an usability value of 77.4% and an evaluation score of 6.99, which can be interpreted as “satisfactory”.

  1. Exploring information systems outsourcing in U.S. hospital-based health care delivery systems.

    Science.gov (United States)

    Diana, Mark L

    2009-12-01

    The purpose of this study is to explore the factors associated with outsourcing of information systems (IS) in hospital-based health care delivery systems, and to determine if there is a difference in IS outsourcing activity based on the strategic value of the outsourced functions. IS sourcing behavior is conceptualized as a case of vertical integration. A synthesis of strategic management theory (SMT) and transaction cost economics (TCE) serves as the theoretical framework. The sample consists of 1,365 hospital-based health care delivery systems that own 3,452 hospitals operating in 2004. The findings indicate that neither TCE nor SMT predicted outsourcing better than the other did. The findings also suggest that health care delivery system managers may not be considering significant factors when making sourcing decisions, including the relative strategic value of the functions they are outsourcing. It is consistent with previous literature to suggest that the high cost of IS may be the main factor driving the outsourcing decision.

  2. Identifying usability issues for personalization during formative evaluations: a comparisons of three methods

    NARCIS (Netherlands)

    van Velsen, Lex Stefan; van der Geest, Thea; Klaassen, R.F.

    2011-01-01

    A personalized system is one that generates unique output for each individual. As a result, personalization has transformed the interaction between the user and the system, and specific new usability issues have arisen. Methods used for evaluating personalized systems should be able to reveal the

  3. From Usability Testing to Clinical Simulations: Bringing Context into the Design and Evaluation of Usable and Safe Health Information Technologies

    DEFF Research Database (Denmark)

    Kushniruk, Andre; Nøhr, Christian; Jensen, Sanne

    2013-01-01

    of clinical context into stronger focus. This involves testing of systems with representative users doing representative tasks, in representative settings/environments. Results: Application of methods where realistic clinical scenarios are used to drive the study of users interacting with systems under...... such evaluation can be used to improve both the usability and safety of HIT. In addition, recent work has shown that clinical simulations, in particular those conducted in-situ, can lead to considerable benefits when compared to the costs of running such studies. Conclusion: In order to bring context of use...

  4. Micelles As Delivery System for Cancer Treatment.

    Science.gov (United States)

    Keskin, Dilek; Tezcaner, Aysen

    2017-01-01

    Micelles are nanoparticles formed by the self-assembly of amphiphilic block copolymers in certain solvents above concentrations called critical micelle concentration (CMC). Micelles are used in different fields like food, cosmetics, medicine, etc. These nanosized delivery systems are under spotlight in the recent years with new achievements in terms of their in vivo stability, ability to protect entrapped drug, release kinetics, ease of cellular penetration and thereby increased therapeutic efficacy. Drug loaded micelles can be prepared by dialysis, oil-in-water method, solid dispersion, freezing, spray drying, etc. The aim of this review is to give an overview of the research on micelles (in vitro, in vivo and clinical) as delivery system for cancer treatment. Passive targeting is one route for accumulation of nanosized micellar drug formulations. Many research groups from both academia and industry focus on developing new strategies for improving the therapeutic efficacy of micellar systems (active targeting to the tumor site, designing multidrug delivery systems for overcoming multidrug resistance or micelles formed by prodrug conjugates, etc). There is only one micellar drug formulation in South Korea that has reached clinical practice. However, there are many untargeted anticancer drug loaded micellar formulations in clinical trials, which have potential for use in clinics. Many more products are expected to be on the market in the near future. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  5. The role of usability in e-lexicography

    Directory of Open Access Journals (Sweden)

    André H. du Plessis

    2017-05-01

    Full Text Available In the development of the metalexicography, the primary focus of metalexicographers was on the development of printed dictionaries. As technology advances, the focus now shifts towards online and electronic products. Tarp (2009:23–24 posits that this shift results in metalexicographic shortcomings. This means that the theories used to create and evaluate dictionaries are not sufficient anymore. Bergenholtz and Bothma (2011:54 show that dictionaries as data carriers are now not only limited to the field of lexicography, but also to information technological fields. For current lexicographers to be successful in the digital age, the theories used in designing, developing and critiquing dictionaries must adapt with regards to current information technological trends, norms and practices. One aspect that must be addressed is the usability of dictionaries and other electronic lexicographic tools. By using usability theories and standards, current metalexicographical principles can be adapted for the digital age in a streamlined fashion. This study aims to show how usability theories and standards can be advantageous for metalexicography and that future electronic metalexicographic endeavours should not be undertaken without considering the usability as part of the theoretical framework.

  6. Usability perspective on social media sites' adoption in the B2B context

    OpenAIRE

    Lacka, Ewelina; Chong, Alain

    2016-01-01

    While social media sites have been successfully adopted and used in the B2C context, they are perceived to be irrelevant in B2B marketing. This is due to marketers' perception of poor usability of these sites in the B2B sector. This study investigates the usability of social media sites when adopted for B2B marketing purposes in the one of world's largest social media market: China. Specifically, by extending the Technology Acceptance Model with Nielsen's Model of Attributes of System Accepta...

  7. Drug Delivery Systems for Imaging and Therapy of Parkinson's Disease.

    Science.gov (United States)

    Gunay, Mine Silindir; Ozer, A Yekta; Chalon, Sylvie

    2016-01-01

    Although a variety of therapeutic approaches are available for the treatment of Parkinson's disease, challenges limit effective therapy. Among these challenges are delivery of drugs through the blood brain barier to the target brain tissue and the side effects observed during long term administration of antiparkinsonian drugs. The use of drug delivery systems such as liposomes, niosomes, micelles, nanoparticles, nanocapsules, gold nanoparticles, microspheres, microcapsules, nanobubbles, microbubbles and dendrimers is being investigated for diagnosis and therapy. This review focuses on formulation, development and advantages of nanosized drug delivery systems which can penetrate the central nervous system for the therapy and/or diagnosis of PD, and highlights future nanotechnological approaches. It is esential to deliver a sufficient amount of either therapeutic or radiocontrast agents to the brain in order to provide the best possible efficacy or imaging without undesired degradation of the agent. Current treatments focus on motor symptoms, but these treatments generally do not deal with modifying the course of Parkinson's disease. Beyond pharmacological therapy, the identification of abnormal proteins such as α -synuclein, parkin or leucine-rich repeat serine/threonine protein kinase 2 could represent promising alternative targets for molecular imaging and therapy of Parkinson's disease. Nanotechnology and nanosized drug delivery systems are being investigated intensely and could have potential effect for Parkinson's disease. The improvement of drug delivery systems could dramatically enhance the effectiveness of Parkinson's Disease therapy and reduce its side effects.

  8. Usability and clinical efficacy of diabetes mobile applications for adults with type 2 diabetes: A systematic review.

    Science.gov (United States)

    Fu, Helen; McMahon, Siobhan K; Gross, Cynthia R; Adam, Terrence J; Wyman, Jean F

    2017-09-01

    To assess the usability and clinical effectiveness of diabetes mobile applications (diabetes apps) developed for adults with type 2 diabetes. A systematic review of the usability and effectiveness of diabetes apps was conducted. Searches were performed using MEDLINE, EMBASE, COMPENDEX, and IEEE XPLORE for articles published from January 1, 2011, to January 17, 2017. Search terms included: diabetes, mobile apps, and mobile health (mHealth). The search yielded 723 abstracts of which seven usability studies and ten clinical effectiveness studies met the inclusion criteria from 20 publications. Usability, as measured by satisfaction ratings from experts and patients, ranged from 38% to 80%. Usability problem ratings ranged from moderate to catastrophic. Top usability problems are multi-steps task, limited functionality and interaction, and difficult system navigation. Clinical effectiveness, measured by reductions in HbA1c, ranged from 0.15% to 1.9%. Despite meager satisfaction ratings and major usability problems, there is some limited evidence supporting the effectiveness of diabetes apps to improve glycemic control for adults with type 2 diabetes. Findings strongly suggest that efforts to improve user satisfaction, incorporate established principles of health behavior change, and match apps to user characteristics will increase the therapeutic impact of diabetes apps. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Structured emulsion-based delivery systems: controlling the digestion and release of lipophilic food components.

    Science.gov (United States)

    McClements, David Julian; Li, Yan

    2010-09-15

    There is a need for edible delivery systems to encapsulate, protect and release bioactive and functional lipophilic constituents within the food and pharmaceutical industries. These delivery systems could be used for a number of purposes: controlling lipid bioavailability; targeting the delivery of bioactive components within the gastrointestinal tract; and designing food matrices that delay lipid digestion and induce satiety. Emulsion technology is particularly suited for the design and fabrication of delivery systems for lipids. In this article we provide an overview of a number of emulsion-based technologies that can be used as edible delivery systems by the food and other industries, including conventional emulsions, nanoemulsions, multilayer emulsions, solid lipid particles, and filled hydrogel particles. Each of these delivery systems can be produced from food-grade (GRAS) ingredients (e.g., lipids, proteins, polysaccharides, surfactants, and minerals) using relatively simple processing operations (e.g., mixing, homogenizing, and thermal processing). The structure, preparation, and utilization of each type of delivery system for controlling lipid digestion are discussed. This knowledge can be used to select the most appropriate emulsion-based delivery system for specific applications, such as encapsulation, controlled digestion, and targeted release. Copyright 2010 Elsevier B.V. All rights reserved.

  10. Usability analysis of indoor map application in a shopping centre

    Science.gov (United States)

    Dewi, R. S.; Hadi, R. K.

    2018-04-01

    Although indoor navigation is still new in Indonesia, its future development is very promising. Similar to the outdoor one, the indoor navigation technology provides several important functions to support route and landmark findings. Furthermore, there is also a need that indoor navigation can support the public safety especially during disaster evacuation process in a building. It is a common that the indoor navigation technologies are built as applications where users can access this technology using their smartphones, tablets, or personal computers. Therefore, a usability analysis is important to ensure the indoor navigation applications can be operated by users with highest functionality. Among several indoor map applications which were available in the market, this study chose to analyse indoor Google Maps due to its availability and popularity in Indonesia. The experiments to test indoor Google Maps was conducted in one of the biggest shopping centre building in Surabaya, Indonesia. The usability was measured by employing System Usability Scale (SUS) questionnaire. The result showed that the SUS score of indoor Google Maps was below the average score of other cellular applications to indicate the users still had high difficulty in operating and learning the features of indoor Google Maps.

  11. Privacy Enhancing Keyboard: Design, Implementation, and Usability Testing

    Directory of Open Access Journals (Sweden)

    Zhen Ling

    2017-01-01

    Full Text Available To protect users from numerous password inference attacks, we invent a novel context aware privacy enhancing keyboard (PEK for Android touch-based devices. Usually PEK would show a QWERTY keyboard when users input text like an email or a message. Nevertheless, whenever users enter a password in the input box on his or her touch-enabled device, a keyboard will be shown to them with the positions of the characters shuffled at random. PEK has been released on the Google Play since 2014. However, the number of installations has not lived up to our expectation. For the purpose of usable security and privacy, we designed a two-stage usability test and performed two rounds of iterative usability testing in 2016 and 2017 summer with continuous improvements of PEK. The observations from the usability testing are educational: (1 convenience plays a critical role when users select an input method; (2 people think those attacks that PEK prevents are remote from them.

  12. A human reliability based usability evaluation method for safety-critical software

    International Nuclear Information System (INIS)

    Boring, R. L.; Tran, T. Q.; Gertman, D. I.; Ragsdale, A.

    2006-01-01

    Boring and Gertman (2005) introduced a novel method that augments heuristic usability evaluation methods with that of the human reliability analysis method of SPAR-H. By assigning probabilistic modifiers to individual heuristics, it is possible to arrive at the usability error probability (UEP). Although this UEP is not a literal probability of error, it nonetheless provides a quantitative basis to heuristic evaluation. This method allows one to seamlessly prioritize and identify usability issues (i.e., a higher UEP requires more immediate fixes). However, the original version of this method required the usability evaluator to assign priority weights to the final UEP, thus allowing the priority of a usability issue to differ among usability evaluators. The purpose of this paper is to explore an alternative approach to standardize the priority weighting of the UEP in an effort to improve the method's reliability. (authors)

  13. Development and testing of new upper-limb prosthetic devices: research designs for usability testing.

    Science.gov (United States)

    Resnik, Linda

    2011-01-01

    The purposes of this article are to describe usability testing and introduce designs and methods of usability testing research as it relates to upper-limb prosthetics. This article defines usability, describes usability research, discusses research approaches to and designs for usability testing, and highlights a variety of methodological considerations, including sampling, sample size requirements, and usability metrics. Usability testing is compared with other types of study designs used in prosthetic research.

  14. MO-A-16A-01: QA Procedures and Metrics: In Search of QA Usability

    International Nuclear Information System (INIS)

    Sathiaseelan, V; Thomadsen, B

    2014-01-01

    Radiation therapy has undergone considerable changes in the past two decades with a surge of new technology and treatment delivery methods. The complexity of radiation therapy treatments has increased and there has been increased awareness and publicity about the associated risks. In response, there has been proliferation of guidelines for medical physicists to adopt to ensure that treatments are delivered safely. Task Group recommendations are copious, and clinical physicists' hours are longer, stretched to various degrees between site planning and management, IT support, physics QA, and treatment planning responsibilities.Radiation oncology has many quality control practices in place to ensure the delivery of high-quality, safe treatments. Incident reporting systems have been developed to collect statistics about near miss events at many radiation oncology centers. However, tools are lacking to assess the impact of these various control measures. A recent effort to address this shortcoming is the work of Ford et al (2012) who recently published a methodology enumerating quality control quantification for measuring the effectiveness of safety barriers. Over 4000 near-miss incidents reported from 2 academic radiation oncology clinics were analyzed using quality control quantification, and a profile of the most effective quality control measures (metrics) was identified.There is a critical need to identify a QA metric to help the busy clinical physicists to focus their limited time and resources most effectively in order to minimize or eliminate errors in the radiation treatment delivery processes. In this symposium the usefulness of workflows and QA metrics to assure safe and high quality patient care will be explored.Two presentations will be given:Quality Metrics and Risk Management with High Risk Radiation Oncology ProceduresStrategies and metrics for quality management in the TG-100 Era Learning Objectives: Provide an overview and the need for QA usability

  15. MO-A-16A-01: QA Procedures and Metrics: In Search of QA Usability

    Energy Technology Data Exchange (ETDEWEB)

    Sathiaseelan, V [Northwestern Memorial Hospital, Chicago, IL (United States); Thomadsen, B [University of Wisconsin, Madison, WI (United States)

    2014-06-15

    Radiation therapy has undergone considerable changes in the past two decades with a surge of new technology and treatment delivery methods. The complexity of radiation therapy treatments has increased and there has been increased awareness and publicity about the associated risks. In response, there has been proliferation of guidelines for medical physicists to adopt to ensure that treatments are delivered safely. Task Group recommendations are copious, and clinical physicists' hours are longer, stretched to various degrees between site planning and management, IT support, physics QA, and treatment planning responsibilities.Radiation oncology has many quality control practices in place to ensure the delivery of high-quality, safe treatments. Incident reporting systems have been developed to collect statistics about near miss events at many radiation oncology centers. However, tools are lacking to assess the impact of these various control measures. A recent effort to address this shortcoming is the work of Ford et al (2012) who recently published a methodology enumerating quality control quantification for measuring the effectiveness of safety barriers. Over 4000 near-miss incidents reported from 2 academic radiation oncology clinics were analyzed using quality control quantification, and a profile of the most effective quality control measures (metrics) was identified.There is a critical need to identify a QA metric to help the busy clinical physicists to focus their limited time and resources most effectively in order to minimize or eliminate errors in the radiation treatment delivery processes. In this symposium the usefulness of workflows and QA metrics to assure safe and high quality patient care will be explored.Two presentations will be given:Quality Metrics and Risk Management with High Risk Radiation Oncology ProceduresStrategies and metrics for quality management in the TG-100 Era Learning Objectives: Provide an overview and the need for QA usability

  16. Waste Feed Delivery Transfer System Analysis

    Energy Technology Data Exchange (ETDEWEB)

    JULYK, L.J.

    2000-05-05

    This document provides a documented basis for the required design pressure rating and pump pressure capacity of the Hanford Site waste-transfer system in support of the waste feed delivery to the privatization contractor for vitrification. The scope of the analysis includes the 200 East Area double-shell tank waste transfer pipeline system and the associated transfer system pumps for a11 Phase 1B and Phase 2 waste transfers from AN, AP, AW, AY, and A2 Tank Farms.

  17. Waste Feed Delivery Transfer System Analysis

    International Nuclear Information System (INIS)

    JULYK, L.J.

    2000-01-01

    This document provides a documented basis for the required design pressure rating and pump pressure capacity of the Hanford Site waste-transfer system in support of the waste feed delivery to the privatization contractor for vitrification. The scope of the analysis includes the 200 East Area double-shell tank waste transfer pipeline system and the associated transfer system pumps for a11 Phase 1B and Phase 2 waste transfers from AN, AP, AW, AY, and A2 Tank Farms

  18. Nanoscale Nutrient Delivery Systems for Food Applications: Improving Bioactive Dispersibility, Stability, and Bioavailability.

    Science.gov (United States)

    McClements, David Julian

    2015-07-01

    There has been a surge of interest in the development of nanoscale systems for the encapsulation, protection, and delivery of lipophilic nutrients, vitamins, and nutraceuticals. This review article highlights the challenges associated with incorporating these lipophilic bioactive components into foods, and then discusses potential nanoscale delivery systems that can be used to overcome these challenges. In particular, the desirable characteristics required for any nanoscale delivery system are presented, as well as methods of fabricating them and of characterizing them. An overview of different delivery systems is given, such as microemulsions, nanoemulsions, emulsions, microgels, and biopolymer nanoparticles, and their potential applications are discussed. Nanoscale delivery systems have considerable potential within the food industry, but they must be carefully formulated to ensure that they are safe, economically viable, and effective. Nanoscale delivery systems have numerous potential applications in the food industry for encapsulating, protecting, and releasing bioactive agents, such as nutraceuticals and vitamins. This review article highlights methods for designing, fabricating, characterizing, and utilizing edible nanoparticles from a variety of different food-grade ingredients. © 2015 Institute of Food Technologists®

  19. Evaluating the usability of an interactive, bi-lingual, touchscreen-enabled breastfeeding educational programme: application of Nielson’s heuristics

    Directory of Open Access Journals (Sweden)

    Ashish Joshi

    2015-03-01

    Full Text Available Background: Usability challenges have to be met in an interactive computer program development and should meet all users’ needs. Objective: The study purpose was to conduct heuristic evaluation of an interactive, bilingual touch screen enabled breastfeeding educational program for Hispanic women living in rural settings.Methods: Two usability experts used Nielsen’s heuristics while reviewing the user interface in May 2013 using principles of Nielson’s Heuristics. Nielson’s heuristics are a set of usability engineering principles developed to identify issues in user interface design and involves analysis of the interface. The heuristic evaluations were carried out in the interface, program sections, and interactive educational modules. A total of 271 screens were evaluated and included: interface (n=5, program sections (n=223 and educational content (n=43.Results: A total of 97 violations were identified and were mostly related to interface (8violations/5screens and program components (89violations/266screens. The most common violations reported were recognition rather than recall (62%, n=60, consistency and standards (14%, n=14, and match between the system and real world (9%, n= 9. Majority of the violations had minor usability issues (73%, n=71. The only catastrophic violation reported was due to the visibility of system status in the assessment modules.Conclusion: The results demonstrated that the system was more consistent with Nielsen’s usability heuristics. 

  20. Buccal mucosa as a route for systemic drug delivery: a review.

    Science.gov (United States)

    Shojaei, A H

    1998-01-01

    Within the oral mucosal cavity, the buccal region offers an attractive route of administration for systemic drug delivery. The mucosa has a rich blood supply and it is relatively permeable. It is the objective of this article to review buccal drug delivery by discussing the structure and environment of the oral mucosa and the experimental methods used in assessing buccal drug permeation/absorption. Buccal dosage forms will also be reviewed with an emphasis on bioadhesive polymeric based delivery systems

  1. A Sample Delivery System for Planetary Missions

    Data.gov (United States)

    National Aeronautics and Space Administration — The project will develop, test and characterize the performance of a prototype /sample delivery system (SDS) implemented as an end effector on a robotic arm capable...

  2. Optimizing the user interface of a data entry module for an electronic patient record for cardiac rehabilitation: A mixed method usability approach.

    Science.gov (United States)

    van Engen-Verheul, Mariëtte M; Peute, Linda W P; de Keizer, Nicolette F; Peek, Niels; Jaspers, Monique W M

    2016-03-01

    Cumbersome electronic patient record (EPR) interfaces may complicate data-entry in clinical practice. Completeness of data entered in the EPR determines, among other things, the value of computerized clinical decision support (CCDS). Quantitative usability evaluations can provide insight into mismatches between the system design model of data entry and users' data entry behavior, but not into the underlying causes for these mismatches. Mixed method usability evaluation studies may provide these insights, and thus support generating redesign recommendations for improving an EPR system's data entry interface. To improve the usability of the data entry interface of an EPR system with CCDS in the field of cardiac rehabilitation (CR), and additionally, to assess the value of a mixed method usability approach in this context. Seven CR professionals performed a think-aloud usability evaluation both before (beta-version) and after the redesign of the system. Observed usability problems from both evaluations were analyzed and categorized using Zhang et al.'s heuristic principles of good interface design. We combined the think-aloud usability evaluation of the system's beta-version with the measurement of a new usability construct: users' deviations in action sequence from the system's predefined data entry order sequence. Recommendations for redesign were implemented. We assessed whether the redesign improved CR professionals' (1) task efficacy (with respect to the completeness of data they collected), and (2) task efficiency (with respect to the average number of mouse clicks they needed to complete data entry subtasks). With the system's beta version, 40% of health care professionals' navigation actions through the system deviated from the predefined next system action. The causes for these deviations as revealed by the think-aloud method mostly concerned mismatches between the system design model for data entry action sequences and users expectations of these action

  3. Drug delivery system and breast cancer cells

    Science.gov (United States)

    Colone, Marisa; Kaliappan, Subramanian; Calcabrini, Annarica; Tortora, Mariarosaria; Cavalieri, Francesca; Stringaro, Annarita

    2016-06-01

    Recently, nanomedicine has received increasing attention for its ability to improve the efficacy of cancer therapeutics. Nanosized polymer therapeutic agents offer the advantage of prolonged circulation in the blood stream, targeting to specific sites, improved efficacy and reduced side effects. In this way, local, controlled delivery of the drug will be achieved with the advantage of a high concentration of drug release at the target site while keeping the systemic concentration of the drug low, thus reducing side effects due to bioaccumulation. Various drug delivery systems such as nanoparticles, liposomes, microparticles and implants have been demonstrated to significantly enhance the preventive/therapeutic efficacy of many drugs by increasing their bioavailability and targetability. As these carriers significantly increase the therapeutic effect of drugs, their administration would become less cost effective in the near future. The purpose of our research work is to develop a delivery system for breast cancer cells using a microvector of drugs. These results highlight the potential uses of these responsive platforms suited for biomedical and pharmaceutical applications. At the request of all authors of the paper an updated version was published on 12 July 2016. The manuscript was prepared and submitted without Dr. Francesca Cavalieri's contribution and her name was added without her consent. Her name has been removed in the updated and re-published article.

  4. Users Views about the Usability of Digital Libraries

    Science.gov (United States)

    Koohang, Alex; Ondracek, James

    2005-01-01

    This study examined users' views about the usability of digital libraries' current and perceived importance. Age, gender, prior experience with the Internet, college status, and digital library proficiency are the independent variables. Users' current views about the usability of digital libraries and users perceived importance of digital library…

  5. Information users and usability in the digital age

    CERN Document Server

    Chowdhury, G G

    2013-01-01

    Gives an overview of the necessary issues relating to information users and the usability of information services in the digital world, including user-centred design, and the characteristics and behaviour of information users. This book helps readers understand why information users and the usability of information services are important.

  6. A Usability Evaluation of Academic Virtual Reference Services

    Science.gov (United States)

    Chow, Anthony S.; Croxton, Rebecca A.

    2014-01-01

    This study examined the usability of five virtual reference services--instant messenger chat, e-mail, telephone, text messaging, and Skype videoconferencing--by having 31 undergraduate and graduate students evaluate the usability of the virtual reference services of two different universities. The study's results suggest that user preference and…

  7. UX Professionals’ Definitions of Usability and UX

    DEFF Research Database (Denmark)

    Rajanen, Dorina; Clemmensen, Torkil; Iivari, Netta

    2017-01-01

    This paper examines the views of user experience (UX) professionals on the definitions of usability and UX, and compares the findings between countries and within different socio-cultural groups. A mixed-method analysis was employed on data gathered on 422 professionals through a survey in Turkey......, Finland, Denmark, France, and Malaysia. Usability appears to be an established concept, respondents across all countries agreeing on the importance of the ISO 9241-11 definition. There is also a tendency that UX professionals attach organizational perspective to usability. UX professionals diverge when...... defining UX, and there are systematic differences related to socio-cultural conditions. UX professionals in Finland and France incline more towards the definition highlighting the experiential qualities, when compared to Turkey and Malaysia that incline towards the definition reflecting the ease of use...

  8. EVALUATION OF THE USABILITY OF MOBILE COMPUTER SYSTEM FOR EDUCATIVE ADVISING IN THE UNIVERSIDAD AUTÓNOMA INDÍGENA DE MEXICO

    Directory of Open Access Journals (Sweden)

    Erasmo Miranda-Bojórquez

    2011-01-01

    Full Text Available Tests of evaluation and functionality of a system computer denominated FoldMobile in la Universidad Autonoma Indigena de Mexico (UAIM have taken place. This system provides with sufficient information to carry out the pursuit of the learning of student when it takes place the actual interaction of the adviser and the student in any place of the university campus and within an atmosphere totally disconnected of any network of devices used for storage. For it one has settled in a digital personal assistant (PDA. The purpose of the tests is to measure its usability and to carry out a redesign of the system being used for it the methodology based on users. Especially the propose heuristic evaluation by Nielsen through its ten rules. An experiment was carried out to evaluate the usability of the system and graphical interfaces to offer simpler solutions that they approach the mental models of the users and to ensure that the system is accepted and more used. The results gave the approval of the experts to the simplicity of the screens and the information presented/displayed through a consistent and familiar language but also suggested a redesign as far as the obtaining of aid of use of the system. In agreement with the results of the experiment the level of acceptance from the user was high, describing its experience like satisfactory, exciting and easy to use. The benefits are in cost and time of development of the system and more propitious conditions so that he is really used.

  9. Nursing Services Delivery Theory: an open system approach

    Science.gov (United States)

    Meyer, Raquel M; O’Brien-Pallas, Linda L

    2010-01-01

    meyer r.m. & o’brien-pallas l.l. (2010)Nursing services delivery theory: an open system approach. Journal of Advanced Nursing66(12), 2828–2838. Aim This paper is a discussion of the derivation of the Nursing Services Delivery Theory from the application of open system theory to large-scale organizations. Background The underlying mechanisms by which staffing indicators influence outcomes remain under-theorized and unmeasured, resulting in a ‘black box’ that masks the nature and organization of nursing work. Theory linking nursing work, staffing, work environments, and outcomes in different settings is urgently needed to inform management decisions about the allocation of nurse staffing resources in organizations. Data sources A search of CINAHL and Business Source Premier for the years 1980–2008 was conducted using the following terms: theory, models, organization, organizational structure, management, administration, nursing units, and nursing. Seminal works were included. Discussion The healthcare organization is conceptualized as an open system characterized by energy transformation, a dynamic steady state, negative entropy, event cycles, negative feedback, differentiation, integration and coordination, and equifinality. The Nursing Services Delivery Theory proposes that input, throughput, and output factors interact dynamically to influence the global work demands placed on nursing work groups at the point of care in production subsystems. Implications for nursing The Nursing Services Delivery Theory can be applied to varied settings, cultures, and countries and supports the study of multi-level phenomena and cross-level effects. Conclusion The Nursing Services Delivery Theory gives a relational structure for reconciling disparate streams of research related to nursing work, staffing, and work environments. The theory can guide future research and the management of nursing services in large-scale healthcare organizations. PMID:20831573

  10. Sustained subconjunctival protein delivery using a thermosetting gel delivery system.

    Science.gov (United States)

    Rieke, Erin R; Amaral, Juan; Becerra, S Patricia; Lutz, Robert J

    2010-02-01

    An effective treatment modality for posterior eye diseases would provide prolonged delivery of therapeutic agents, including macromolecules, to eye tissues using a safe and minimally invasive method. The goal of this study was to assess the ability of a thermosetting gel to deliver a fluorescently labeled protein, Alexa 647 ovalbumin, to the choroid and retina of rats following a single subconjunctival injection of the gel. Additional experiments were performed to compare in vitro to in vivo ovalbumin release rates from the gel. The ovalbumin content of the eye tissues was monitored by spectrophotometric assays of tissue extracts of Alexa 647 ovalbumin from dissected sclera, choroid, and retina at time points ranging from 2 h to 14 days. At the same time points, fluorescence microscopy images of tissue samples were also obtained. Measurement of intact ovalbumin was verified by LDS-PAGE analysis of the tissue extract solutions. In vitro release of Alexa 488 ovalbumin into 37 degrees C PBS solutions from ovalbumin-loaded gel pellets was also monitored over time by spectrophotometric assay. In vivo ovalbumin release rates were determined by measurement of residual ovalbumin extracted from gel pellets removed from rat eyes at various time intervals. Our results indicate that ovalbumin concentrations can be maintained at measurable levels in the sclera, choroid, and retina of rats for up to 14 days using the thermosetting gel delivery system. The concentration of ovalbumin exhibited a gradient that decreased from sclera to choroid and to retina. The in vitro release rate profiles were similar to the in vivo release profiles. Our findings suggest that the thermosetting gel system may be a feasible method for safe and convenient sustained delivery of proteins to choroidal and retinal tissue in the posterior segments of the eye.

  11. A Comparison of Quantitative and Qualitative Data from a Formative Usability Evaluation of an Augmented Reality Learning Scenario

    Directory of Open Access Journals (Sweden)

    Dragos Daniel IORDACHE

    2009-01-01

    Full Text Available The proliferation of augmented reality (AR technologies creates opportunities for the devel-opment of new learning scenarios. More recently, the advances in the design and implementation of desktop AR systems make it possible the deployment of such scenarios in primary and secondary schools. Usability evaluation is a precondition for the pedagogical effectiveness of these new technologies and requires a systematic approach for finding and fixing usability problems. In this paper we present an approach to a formative usability evaluation based on heuristic evaluation and user testing. The basic idea is to compare and integrate quantitative and qualitative measures in order to increase confidence in results and enhance the descriptive power of the usability evaluation report.

  12. Integrating discount usability in scrum development process in Ethiopia

    DEFF Research Database (Denmark)

    Teka, Degif; Dittrich, Y.; Kifle, Mesfin

    2017-01-01

    be adapted and integrated into the Scrum-agile development with especial emphasis on the Ethiopian context. The research aims at adapting software engineering and ICT development methods to the specific situation and integrating user-centered design (UCD) and lightweight usability methods into agile...... end users and developers. Culturally adapted user pair testing and heuristic evaluation supported usability testing and supported developers in getting early feedback. Integrated approach of discount usability with the Scrum process has been developed and evaluated first with the involved...

  13. Nature engineered diatom biosilica as drug delivery systems.

    Science.gov (United States)

    Uthappa, U T; Brahmkhatri, Varsha; Sriram, G; Jung, Ho-Young; Yu, Jingxian; Kurkuri, Nikita; Aminabhavi, Tejraj M; Altalhi, Tariq; Neelgund, Gururaj M; Kurkuri, Mahaveer D

    2018-05-14

    Diatoms, unicellular photosynthetic algae covered with siliceous cell wall, are also called frustule. These are the most potential naturally available materials for the development of cost-effective drug delivery systems because of their excellent biocompatibility, high surface area, low cost and ease of surface modification. Mesoporous silica materials such as MCM-41 and SBA-15 have been extensively used in drug delivery area. Their synthesis is challenging, time consuming, requires toxic chemicals and are energy intensive, making the entire process expensive and non-viable. Therefore, it is necessary to explore alternative materials. Surprisingly, nature has provided some exciting materials called diatoms; biosilica is one such a material that can be potentially used as a drug delivery vehicle. The present review focuses on different types of diatom species used in drug delivery with respect to their structural properties, morphology, purification process and surface functionalization. In this review, recent advances along with their limitations as well as the future scope to develop them as potential drug delivery vehicles are discussed. Copyright © 2018. Published by Elsevier B.V.

  14. Analysis and Design Information System Logistics Delivery Service in Pt Repex Wahana

    Directory of Open Access Journals (Sweden)

    Stephanie Surja

    2015-12-01

    Full Text Available Analysis and Design of Logistic Delivery System in PT Repex Wahana aims to analyze company’s need in existing business process of logistic delivery service. This will then be used in the development of an integrated system that can address the problems in the running process of sending and tracking the whereaboutsor status of the delivered goods which are the core business processes in the enterprise. The result then will be used as basis in the development of integrated information system in pursuit of corporate solution for process business automation, delivery process, inventory, and logistic delivery tracking, which is the core of the company business process, and it will be documented using Unified Modeling Language. The information system is meant to simplify the delivery and tracking process in the company, besides will minimize lost and error of data which is often happened because of the manual and unorganized transaction data processing.

  15. A framework for characterizing usability requirements elicitation and analysis methodologies (UREAM)

    NARCIS (Netherlands)

    Trienekens, J.J.M.; Kusters, R.J.; Mannaert, H.

    2012-01-01

    Dedicated methodologies for the elicitation and analysis of usability requirements have been proposed in literature, usually developed by usability experts. The usability of these approaches by non-expert software engineers is not obvious. In this paper, the objective is to support developers and

  16. Approaches and Challenges of Engineering Implantable Microelectromechanical Systems (MEMS Drug Delivery Systems for in Vitro and in Vivo Applications

    Directory of Open Access Journals (Sweden)

    Ken-Tye Yong

    2012-11-01

    Full Text Available Despite the advancements made in drug delivery systems over the years, many challenges remain in drug delivery systems for treating chronic diseases at the personalized medicine level. The current urgent need is to develop novel strategies for targeted therapy of chronic diseases. Due to their unique properties, microelectromechanical systems (MEMS technology has been recently engineered as implantable drug delivery systems for disease therapy. This review examines the challenges faced in implementing implantable MEMS drug delivery systems in vivo and the solutions available to overcome these challenges.

  17. Oral heparin delivery: design and in vivo evaluation of a stomach-targeted mucoadhesive delivery system.

    Science.gov (United States)

    Schmitz, Thierry; Leitner, Verena M; Bernkop-Schnürch, Andreas

    2005-05-01

    Low molecular weight heparin (LMWH) is an agent of choice in the anti-coagulant therapy and prophylaxis of thrombosis and coronary syndromes. However, the therapeutic use is partially limited due to a poor oral bioavailability. It was therefore the aim of this study to design and evaluate a highly efficient stomach-targeted oral delivery system for LMWH. In order to appraise the influence of the molecular weight on the oral bioavailability, mini-tablets comprising 3 kDa (279 IU) and 6 kDa (300 IU) LMWH, respectively, were generated and tested in vivo in rats. The potential of the test formulations based on thiolated polycarbophil, was evaluated in comparison to hydroxyethylcellulose (HEC) as control carrier matrix. The plasma levels of LMWH after oral versus subcutaneous administration were determined in order to calculate the relative bioavailability. With the delivery system containing 3 kDa LMWH (279 IU) a relative bioavailability of 19.1% was achieved, offering a significantly (p thiolated polymers are a promising tool for the non-invasive stomach-targeted systemic delivery of LMWH as model for a hydrophilic macromolecular polysaccharide. Copyright 2005 Wiley-Liss, Inc

  18. Colon-targeted oral drug delivery systems: design trends and approaches.

    Science.gov (United States)

    Amidon, Seth; Brown, Jack E; Dave, Vivek S

    2015-08-01

    Colon-specific drug delivery systems (CDDS) are desirable for the treatment of a range of local diseases such as ulcerative colitis, Crohn's disease, irritable bowel syndrome, chronic pancreatitis, and colonic cancer. In addition, the colon can be a potential site for the systemic absorption of several drugs to treat non-colonic conditions. Drugs such as proteins and peptides that are known to degrade in the extreme gastric pH, if delivered to the colon intact, can be systemically absorbed by colonic mucosa. In order to achieve effective therapeutic outcomes, it is imperative that the designed delivery system specifically targets the drugs into the colon. Several formulation approaches have been explored in the development colon-targeted drug delivery systems. These approaches involve the use of formulation components that interact with one or more aspects of gastrointestinal (GI) physiology, such as the difference in the pH along the GI tract, the presence of colonic microflora, and enzymes, to achieve colon targeting. This article highlights the factors influencing colon-specific drug delivery and colonic bioavailability, and the limitations associated with CDDS. Further, the review provides a systematic discussion of various conventional, as well as relatively newer formulation approaches/technologies currently being utilized for the development of CDDS.

  19. Transferosomes - A vesicular transdermal delivery system for enhanced drug permeation

    Directory of Open Access Journals (Sweden)

    Reshmy Rajan

    2011-01-01

    Full Text Available Transdermal administration of drugs is generally limited by the barrier function of the skin. Vesicular systems are one of the most controversial methods for transdermal delivery of active substances. The interest in designing transdermal delivery systems was relaunched after the discovery of elastic vesicles like transferosomes, ethosomes, cubosomes, phytosomes, etc. This paper presents the composition, mechanisms of penetration, manufacturing and characterization methods of transferosomes as transdermal delivery systems of active substances. For a drug to be absorbed and distributed into organs and tissues and eliminated from the body, it must pass through one or more biological membranes/barriers at various locations. Such a movement of drug across the membrane is called as drug transport. For the drugs to be delivered to the body, they should cross the membranous barrier. The concept of these delivery systems was designed in an attempt to concentrate the drug in the tissues of interest, while reducing the amount of drug in the remaining tissues. Hence, surrounding tissues are not affected by the drug. In addition, loss of drug does not happen due to localization of drug, leading to get maximum efficacy of the medication. Therefore, the phospholipid based carrier systems are of considerable interest in this era.

  20. Leadership Perspectives on Operationalizing the Learning Health Care System in an Integrated Delivery System.

    Science.gov (United States)

    Psek, Wayne; Davis, F Daniel; Gerrity, Gloria; Stametz, Rebecca; Bailey-Davis, Lisa; Henninger, Debra; Sellers, Dorothy; Darer, Jonathan

    2016-01-01

    Healthcare leaders need operational strategies that support organizational learning for continued improvement and value generation. The learning health system (LHS) model may provide leaders with such strategies; however, little is known about leaders' perspectives on the value and application of system-wide operationalization of the LHS model. The objective of this project was to solicit and analyze senior health system leaders' perspectives on the LHS and learning activities in an integrated delivery system. A series of interviews were conducted with 41 system leaders from a broad range of clinical and administrative areas across an integrated delivery system. Leaders' responses were categorized into themes. Ten major themes emerged from our conversations with leaders. While leaders generally expressed support for the concept of the LHS and enhanced system-wide learning, their concerns and suggestions for operationalization where strongly aligned with their functional area and strategic goals. Our findings suggests that leaders tend to adopt a very pragmatic approach to learning. Leaders expressed a dichotomy between the operational imperative to execute operational objectives efficiently and the need for rigorous evaluation. Alignment of learning activities with system-wide strategic and operational priorities is important to gain leadership support and resources. Practical approaches to addressing opportunities and challenges identified in the themes are discussed. Continuous learning is an ongoing, multi-disciplinary function of a health care delivery system. Findings from this and other research may be used to inform and prioritize system-wide learning objectives and strategies which support reliable, high value care delivery.

  1. Implementing a collaborative virtual environment — specification for a usability metamodel

    Directory of Open Access Journals (Sweden)

    Maria L Villegas R

    2009-01-01

    Full Text Available This research presents the results of the first phase of a macro-project for constructing a collaborative virtual environment. It was aimed at selecting a graphical interface from five proposed for such environment, considering each one’s level of usability. Seve- ral standards of usability and user-centered design patterns were studied for specifying interface measurment criteria for speci- fying a usability metamodel; this defined the variables and rules to be taken into accout when measuring graphic user interface (GUI usability level for collaborative virtual environments. The use of metaphors when specifying graphic user interfaces is also briefly looked at as a source of new usability and satisfaction related to such interface use.

  2. Novel delivery systems with nonsteroidal anti-inflammatory drugs

    Directory of Open Access Journals (Sweden)

    Cvijić Sandra

    2016-01-01

    Full Text Available Chronic use of oral nonsteroidal anti-inflammatory drugs (NSAIDs is associated with increased risk of serious gastrointestinal side effects. Therefore, recent trends in the development of NSAIDs aim to reduce the incidence of side effects, and improve patient compliance. One of the strategies to improve efficacy and safety of oral NSAIDs is the development of combination products that contain gastroprotective agents. Several products containing NSAID in combination with proton pump inhibitors (ketoprofen/omeprazole, naproxen/esomeprazole, H2-receptor antagonists (ibuprofen/famotidine, and prostaglandin analogues (diclofenac/misoprostol are currently available on the market. Another approach refer to the special formulation design to allow dose reduction while preserving drug therapeutic efficacy. An example is SoluMatrix® technology, a manufacturing process that produce submicron-sized drug particles with enhanced dissolution and absorption properties. Patented SoluMatrix® technology has been successfully employed to develop low-dose diclofenac, meloxicam, indomethacin and naproxen products. Topical NSAID formulations enable drug delivery to target tissues, while reducing systemic exposure and concomitant side effects associated with oral NSAIDs. Dermal/transdermal NSAID delivery systems are subject of intensive investigation. So far, several 'advanced' drug delivery systems with diclofenac, ibuprofen and ketoprofen have been designed.

  3. A clinical perspective on mucoadhesive buccal drug delivery systems

    Science.gov (United States)

    Gilhotra, Ritu M; Ikram, Mohd; Srivastava, Sunny; Gilhotra, Neeraj

    2014-01-01

    Mucoadhesion can be defined as a state in which two components, of which one is of biological origin, are held together for extended periods of time by the help of interfacial forces. Among the various transmucosal routes, buccal mucosa has excellent accessibility and relatively immobile mucosa, hence suitable for administration of retentive dosage form. The objective of this paper is to review the works done so far in the field of mucoadhesive buccal drug delivery systems (MBDDS), with a clinical perspective. Starting with a brief introduction of the mucoadhesive drug delivery systems, oral mucosa, and the theories of mucoadhesion, this article then proceeds to cover the works done so far in the field of MBDDS, categorizing them on the basis of ailments they are meant to cure. Additionally, we focus on the various patents, recent advancements, and challenges as well as the future prospects for mucoadhesive buccal drug delivery systems. PMID:24683406

  4. Secondary fuel delivery system

    Science.gov (United States)

    Parker, David M.; Cai, Weidong; Garan, Daniel W.; Harris, Arthur J.

    2010-02-23

    A secondary fuel delivery system for delivering a secondary stream of fuel and/or diluent to a secondary combustion zone located in the transition piece of a combustion engine, downstream of the engine primary combustion region is disclosed. The system includes a manifold formed integral to, and surrounding a portion of, the transition piece, a manifold inlet port, and a collection of injection nozzles. A flowsleeve augments fuel/diluent flow velocity and improves the system cooling effectiveness. Passive cooling elements, including effusion cooling holes located within the transition boundary and thermal-stress-dissipating gaps that resist thermal stress accumulation, provide supplemental heat dissipation in key areas. The system delivers a secondary fuel/diluent mixture to a secondary combustion zone located along the length of the transition piece, while reducing the impact of elevated vibration levels found within the transition piece and avoiding the heat dissipation difficulties often associated with traditional vibration reduction methods.

  5. The Usability Analysis of An E-Learning Environment

    Directory of Open Access Journals (Sweden)

    Fulya TORUN

    2015-10-01

    Full Text Available In this research, an E-learning environment is developed for the teacher candidates taking the course on Scientific Research Methods. The course contents were adapted to one of the constructivist approach models referred to as 5E, and an expert opinion was received for the compliance of this model. An usability analysis was also performed to determine the usability of the e-learning environment. The participants of the research comprised 42 teacher candidates. The mixed method was used in the research. 3 different data collection tools were used in order to measure the three basic concepts of usability analyses, which are the dimensions of effectiveness, efficiency and satisfaction. Two of the data collection tools were the scales developed by different researchers and were applied with the approval received from the researchers involved. On the other hand, the usability test as another data tool was prepared by the researchers who conducted this study for the purpose of determining the participants’ success in handling the twelve tasks assigned to them with respect to the use of elearning environment, the seconds they spent on that environment and the number of clicks they performed. Considering the results of the analyses performed within the data obtained, the usability of the developed e-learning environment proved to be at a higher rate.

  6. Usability Evaluation of An Electronic Medication Administration Record (eMAR) Application

    Science.gov (United States)

    Guo, J.; Iribarren, S.; Kapsandoy, S.; Perri, S.; Staggers, N.

    2011-01-01

    Background Electronic medication administration records (eMARs) have been widely used in recent years. However, formal usability evaluations are not yet available for these vendor applications, especially from the perspective of nurses, the largest group of eMAR users. Objective To conduct a formal usability evaluation of an implemented eMAR. Methods Four evaluators examined a commercial vendor eMAR using heuristic evaluation techniques. The evaluators defined seven tasks typical of eMAR use and independently evaluated the application. Consensus techniques were used to obtain 100% agreement of identified usability problems and severity ratings. Findings were reviewed with 5 clinical staff nurses and the Director of Clinical Informatics who verified findings with a small group of clinical nurses. Results Evaluators found 60 usability problems categorized into 233 heuristic violations. Match, Error, and Visibility heuristics were the most frequently violated. Administer Medication and Order and Modify Medications tasks had the highest number of heuristic violations and usability problems rated as major or catastrophic. Conclusion The high number of usability problems could impact the effectiveness, efficiency and satisfaction of nurses’ medication administration activities and may include concerns about patient safety. Usability is a joint responsibility between sites and vendors. We offer a call to action for usability evaluations at all sites and eMAR application redesign as necessary to improve the user experience and promote patient safety. PMID:23616871

  7. A Usability Evaluation Model for Academic Library Websites: Efficiency, Effectiveness and Learnability

    Directory of Open Access Journals (Sweden)

    Soohyung Joo

    2011-12-01

    Full Text Available Purpose – This paper aimed to develop a usability evaluation model and associated survey tool in the context of academic libraries. This study not only proposed a usability evaluation model but also a practical survey tool tailored to academic library websites. Design/methodology – A usability evaluation model has been developed for academic library websites based on literature review and expert consultation. Then, the authors verified the reliability and validity of the usability evaluation model empirically using the survey data from actual users. Statistical analysis, such as descriptive statistics, internal consistency test, and a factor analysis, were applied to ensure both the reliability and validity of the usability evaluation tool. Findings – From the document analysis and expert consultation, this study identified eighteen measurement items to survey the three constructs of the usability, effectiveness, efficiency, and learnability, in academic library websites. The evaluation tool was then validated with regard to data distribution, reliability, and validity. The empirical examination based on 147 actual user responses proved the survey evaluation tool suggested herein is acceptable in assessing academic library website usability. Originality/Value – This research is one of the few studies to engender a practical survey tool in evaluating library website usability. The usability model and corresponding survey tool would be useful for librarians and library administrators in academic libraries who plan to conduct a usability evaluation involving large sample.

  8. Usability Evaluation of a Research Repository and Collaboration Web Site

    Science.gov (United States)

    Zhang, Tao; Maron, Deborah J.; Charles, Christopher C.

    2013-01-01

    This article reports results from an empirical usability evaluation of Human-Animal Bond Research Initiative Central as part of the effort to develop an open access research repository and collaboration platform for human-animal bond researchers. By repurposing and altering key features of the original HUBzero system, Human-Animal Bond Research…

  9. Assessment of Usability Benchmarks: Combining Standardized Scales with Specific Questions

    Directory of Open Access Journals (Sweden)

    Stephanie Bettina Linek

    2011-12-01

    Full Text Available The usability of Web sites and online services is of rising importance. When creating a completely new Web site, qualitative data are adequate for identifying the most usability problems. However, changes of an existing Web site should be evaluated by a quantitative benchmarking process. The proposed paper describes the creation of a questionnaire that allows a quantitative usability benchmarking, i.e. a direct comparison of the different versions of a Web site and an orientation on general standards of usability. The questionnaire is also open for qualitative data. The methodology will be explained by the digital library services of the ZBW.

  10. Workshop on cultural usability and human work interaction design

    DEFF Research Database (Denmark)

    Clemmensen, Torkil; Ørngreen, Rikke; Roese, Kerstin

    2008-01-01

    it into interaction design. The workshop will present current research into cultural usability and human work interaction design. Cultural usability is a comprehensive concept, which adheres to all kinds of contexts in which humans are involved (private family, work, public and private organizations, nature......, Workplace observation, Think-Aloud Usability Test, etc. These techniques often give - seemingly - similar results when applied in diverse cultural settings, but experience shows that we need a deep understanding of the cultural, social and organizational context to interpret the results, and to transform...

  11. Ophthalmic Drug Delivery Systems for Antibiotherapy—A Review

    Science.gov (United States)

    Dubald, Marion; Bourgeois, Sandrine; Andrieu, Véronique; Fessi, Hatem

    2018-01-01

    The last fifty years, ophthalmic drug delivery research has made much progress, challenging scientists about the advantages and limitations of this drug delivery approach. Topical eye drops are the most commonly used formulation in ocular drug delivery. Despite the good tolerance for patients, this topical administration is only focus on the anterior ocular diseases and had a high precorneal loss of drugs due to the tears production and ocular barriers. Antibiotics are popularly used in solution or in ointment for the ophthalmic route. However, their local bioavailability needs to be improved in order to decrease the frequency of administrations and the side effects and to increase their therapeutic efficiency. For this purpose, sustained release forms for ophthalmic delivery of antibiotics were developed. This review briefly describes the ocular administration with the ocular barriers and the currently topical forms. It focuses on experimental results to bypass the limitations of ocular antibiotic delivery with new ocular technology as colloidal and in situ gelling systems or with the improvement of existing forms as implants and contact lenses. Nanotechnology is presently a promising drug delivery way to provide protection of antibiotics and improve pathway through ocular barriers and deliver drugs to specific target sites. PMID:29342879

  12. Ophthalmic Drug Delivery Systems for Antibiotherapy—A Review

    Directory of Open Access Journals (Sweden)

    Marion Dubald

    2018-01-01

    Full Text Available The last fifty years, ophthalmic drug delivery research has made much progress, challenging scientists about the advantages and limitations of this drug delivery approach. Topical eye drops are the most commonly used formulation in ocular drug delivery. Despite the good tolerance for patients, this topical administration is only focus on the anterior ocular diseases and had a high precorneal loss of drugs due to the tears production and ocular barriers. Antibiotics are popularly used in solution or in ointment for the ophthalmic route. However, their local bioavailability needs to be improved in order to decrease the frequency of administrations and the side effects and to increase their therapeutic efficiency. For this purpose, sustained release forms for ophthalmic delivery of antibiotics were developed. This review briefly describes the ocular administration with the ocular barriers and the currently topical forms. It focuses on experimental results to bypass the limitations of ocular antibiotic delivery with new ocular technology as colloidal and in situ gelling systems or with the improvement of existing forms as implants and contact lenses. Nanotechnology is presently a promising drug delivery way to provide protection of antibiotics and improve pathway through ocular barriers and deliver drugs to specific target sites.

  13. Adamantane in Drug Delivery Systems and Surface Recognition

    OpenAIRE

    Adela Štimac; Marina Šekutor; Kata Mlinarić-Majerski; Leo Frkanec; Ruža Frkanec

    2017-01-01

    The adamantane moiety is widely applied in design and synthesis of new drug delivery systems and in surface recognition studies. This review focuses on liposomes, cyclodextrins, and dendrimers based on or incorporating adamantane derivatives. Our recent concept of adamantane as an anchor in the lipid bilayer of liposomes has promising applications in the field of targeted drug delivery and surface recognition. The results reported here encourage the development of novel adamantane-based struc...

  14. Solid Lipid Nanoparticles as Efficient Drug and Gene Delivery Systems: Recent Breakthroughs

    Directory of Open Access Journals (Sweden)

    Jafar Ezzati Nazhad Dolatabadi

    2015-06-01

    Full Text Available In recent years, nanomaterials have been widely applied as advanced drug and gene delivery nanosystems. Among them, solid lipid nanoparticles (SLNs have attracted great attention as colloidal drug delivery systems for incorporating hydrophilic or lipophilic drugs and various macromolecules as well as proteins and nucleic acids. Therefore, SLNs offer great promise for controlled and site specific drug and gene delivery. This article includes general information about SLN structures and properties, production procedures, characterization. In addition, recent progress on development of drug and gene delivery systems using SLNs was reviewed.

  15. Usability Evaluation Method for Agile Software Development

    Directory of Open Access Journals (Sweden)

    Saad Masood Butt

    2015-02-01

    Full Text Available Agile methods are the best fit for tremendously growing software industry due to its flexible and dynamic nature. But the software developed using agile methods do meet the usability standards? To answer this question we can see that majority of agile software development projects currently involve interactive user interface designs, which can only be possible by following User Centered Design (UCD in agile methods. The question here is, how to integrate UCD with agile models. Both Agile models and UCD are iterative in nature but agile models focus on coding and development of software; whereas, UCD focuses on user interface of the software. Similarly, both of them have testing features where the agile model involves automated tested code while UCD involves an expert or a user to test the user interface. In this paper, a new agile usability model is proposed and the evaluation is of the proposed model is presented by practically implementing it in three real life projects. . Key results from these projects clearly show: the proposed agile model incorporates usability evaluation methods, improves the relationship between usability experts to work with agile software experts; in addition, allows agile developers to incorporate the result from UCD into subsequent interactions.

  16. Evaluation of the acceptability and usability of a decision support system to encourage safe and effective use of opioid therapy for chronic, noncancer pain by primary care providers.

    Science.gov (United States)

    Trafton, Jodie; Martins, Susana; Michel, Martha; Lewis, Eleanor; Wang, Dan; Combs, Ann; Scates, Naquell; Tu, Samson; Goldstein, Mary K

    2010-04-01

    To develop and evaluate a clinical decision support system (CDSS) named Assessment and Treatment in Healthcare: Evidenced-Based Automation (ATHENA)-Opioid Therapy, which encourages safe and effective use of opioid therapy for chronic, noncancer pain. CDSS development and iterative evaluation using the analysis, design, development, implementation, and evaluation process including simulation-based and in-clinic assessments of usability for providers followed by targeted system revisions. Volunteers provided detailed feedback to guide improvements in the graphical user interface, and content and design changes to increase clinical usefulness, understandability, clinical workflow fit, and ease of completing guideline recommended practices. Revisions based on feedback increased CDSS usability ratings over time. Practice concerns outside the scope of the CDSS were also identified. Usability testing optimized the CDSS to better address barriers such as lack of provider education, confusion in dosing calculations and titration schedules, access to relevant patient information, provider discontinuity, documentation, and access to validated assessment tools. It also highlighted barriers to good clinical practice that are difficult to address with CDSS technology in its current conceptualization. For example, clinicians indicated that constraints on time and competing priorities in primary care, discomfort in patient-provider communications, and lack of evidence to guide opioid prescribing decisions impeded their ability to provide effective, guideline-adherent pain management. Iterative testing was essential for designing a highly usable and acceptable CDSS; however, identified barriers may limit the impact of the ATHENA-Opioid Therapy system and other CDSS on clinical practices and outcomes unless CDSS are paired with parallel initiatives to address these issues.

  17. The E-health Literacy Demands of Australia's My Health Record: A Heuristic Evaluation of Usability.

    Science.gov (United States)

    Walsh, Louisa; Hemsley, Bronwyn; Allan, Meredith; Adams, Natalie; Balandin, Susan; Georgiou, Andrew; Higgins, Isabel; McCarthy, Shaun; Hill, Sophie

    2017-01-01

    My Health Record is Australia's electronic personal health record system, which was introduced in July 2012. As of August 2017, approximately 21 percent of Australia's total population was registered to use My Health Record. Internationally, usability issues have been shown to negatively influence the uptake and use of electronic health record systems, and this scenario may particularly affect people who have low e-health literacy. It is likely that usability issues are negatively affecting the uptake and use of My Health Record in Australia. To identify potential e-health literacy-related usability issues within My Health Record through a heuristic evaluation method. Between September 14 and October 12, 2016, three of the authors conducted a heuristic evaluation of the two consumer-facing components of My Health Record-the information website and the electronic health record itself. These two components were evaluated against two sets of heuristics-the Health Literacy Online checklist and the Monkman Heuristics. The Health Literacy Online checklist and Monkman Heuristics are evidence-based checklists of web design elements with a focus on design for audiences with low health literacy. During this heuristic evaluation, the investigators individually navigated through the consumer-facing components of My Health Record, recording instances where the My Health Record did not conform to the checklist criteria. After the individual evaluations were completed, the investigators conferred and aggregated their results. From this process, a list of usability violations was constructed. When evaluated against the Health Literacy Online Checklist, the information website demonstrated violations in 12 of 35 criteria, and the electronic health record demonstrated violations in 16 of 35 criteria. When evaluated against the Monkman Heuristics, the information website demonstrated violations in 7 of 11 criteria, and the electronic health record demonstrated violations in 9 of 11

  18. Usability Evaluation Methods for Gesture-Based Games: A Systematic Review.

    Science.gov (United States)

    Simor, Fernando Winckler; Brum, Manoela Rogofski; Schmidt, Jaison Dairon Ebertz; Rieder, Rafael; De Marchi, Ana Carolina Bertoletti

    2016-10-04

    Gestural interaction systems are increasingly being used, mainly in games, expanding the idea of entertainment and providing experiences with the purpose of promoting better physical and/or mental health. Therefore, it is necessary to establish mechanisms for evaluating the usability of these interfaces, which make gestures the basis of interaction, to achieve a balance between functionality and ease of use. This study aims to present the results of a systematic review focused on usability evaluation methods for gesture-based games, considering devices with motion-sensing capability. We considered the usability methods used, the common interface issues, and the strategies adopted to build good gesture-based games. The research was centered on four electronic databases: IEEE, Association for Computing Machinery (ACM), Springer, and Science Direct from September 4 to 21, 2015. Within 1427 studies evaluated, 10 matched the eligibility criteria. As a requirement, we considered studies about gesture-based games, Kinect and/or Wii as devices, and the use of a usability method to evaluate the user interface. In the 10 studies found, there was no standardization in the methods because they considered diverse analysis variables. Heterogeneously, authors used different instruments to evaluate gesture-based interfaces and no default approach was proposed. Questionnaires were the most used instruments (70%, 7/10), followed by interviews (30%, 3/10), and observation and video recording (20%, 2/10). Moreover, 60% (6/10) of the studies used gesture-based serious games to evaluate the performance of elderly participants in rehabilitation tasks. This highlights the need for creating an evaluation protocol for older adults to provide a user-friendly interface according to the user's age and limitations. Through this study, we conclude this field is in need of a usability evaluation method for serious games, especially games for older adults, and that the definition of a methodology

  19. Usability Testing of an Academic Library Web Site: A Case Study.

    Science.gov (United States)

    Battleson, Brenda; Booth, Austin; Weintrop, Jane

    2001-01-01

    Discusses usability testing as a tool for evaluating the effectiveness and ease of use of academic library Web sites; considers human-computer interaction; reviews major usability principles; and explores the application of formal usability testing to an existing site at the University at Buffalo (NY) libraries. (Author/LRW)

  20. Direct Integration: Training Software Developers to Conduct Usability Evaluations

    DEFF Research Database (Denmark)

    Skov, Mikael B.; Stage, Jan

    2008-01-01

    is based on an empirical study where 36 teams with a total of 234 first-year university students on software development and design educations were trained in a simple approach for user-based website usability testing that was taught in a 40 hour course. This approach supported them in planning, conducting......Many improvements of the interplay between usability evaluation and software development rely either on better methods for conducting usability evaluations or on better formats for presenting evaluation results in ways that are useful for software designers and developers. Both approaches involve...... a complete division of work between developers and evaluators, which is an undesirable complexity for many software development projects. This paper takes a different approach by exploring to what extent software developers and designers can be trained to carry out their own usability evaluations. The paper...