WorldWideScience

Sample records for deliver high doses

  1. Design and implementation of a film dosimetry audit tool for comparison of planned and delivered dose distributions in high dose rate (HDR) brachytherapy

    Science.gov (United States)

    Palmer, Antony L.; Lee, Chris; Ratcliffe, Ailsa J.; Bradley, David; Nisbet, Andrew

    2013-10-01

    A novel phantom is presented for ‘full system’ dosimetric audit comparing planned and delivered dose distributions in HDR gynaecological brachytherapy, using clinical treatment applicators. The brachytherapy applicator dosimetry test object consists of a near full-scatter water tank with applicator and film supports constructed of Solid Water, accommodating any typical cervix applicator. Film dosimeters are precisely held in four orthogonal planes bisecting the intrauterine tube, sampling dose distributions in the high risk clinical target volume, points A and B, bladder, rectum and sigmoid. The applicator position is fixed prior to CT scanning and through treatment planning and irradiation. The CT data is acquired with the applicator in a near clinical orientation to include applicator reconstruction in the system test. Gamma analysis is used to compare treatment planning system exported RTDose grid with measured multi-channel film dose maps. Results from two pilot audits are presented, using Ir-192 and Co-60 HDR sources, with a mean gamma passing rate of 98.6% using criteria of 3% local normalization and 3 mm distance to agreement (DTA). The mean DTA between prescribed dose and measured film dose at point A was 1.2 mm. The phantom was funded by IPEM and will be used for a UK national brachytherapy dosimetry audit.

  2. Early effects comparison of X-rays delivered at high-dose-rate pulses by a plasma focus device and at low dose rate on human tumour cells.

    Science.gov (United States)

    Virelli, A; Zironi, I; Pasi, F; Ceccolini, E; Nano, R; Facoetti, A; Gavoçi, E; Fiore, M R; Rocchi, F; Mostacci, D; Cucchi, G; Castellani, G; Sumini, M; Orecchia, R

    2015-09-01

    A comparative study has been performed on the effects of high-dose-rate (DR) X-ray beams produced by a plasma focus device (PFMA-3), to exploit its potential medical applications (e.g. radiotherapy), and low-DR X-ray beams produced by a conventional source (XRT). Experiments have been performed at 0.5 and 2 Gy doses on a human glioblastoma cell line (T98G). Cell proliferation rate and potassium outward currents (IK) have been investigated by time lapse imaging and patch clamp recordings. The results showed that PFMA-3 irradiation has a greater capability to reduce the proliferation rate activity with respect to XRT, while it does not affect IK of T98G cells at any of the dose levels tested. XRT irradiation significantly reduces the mean IK amplitude of T98G cells only at 0.5 Gy. This work confirms that the DR, and therefore the source of radiation, is crucial for the planning and optimisation of radiotherapy applications.

  3. Comparison of film measurements and Monte Carlo simulations of dose delivered with very high-energy electron beams in a polystyrene phantom

    Energy Technology Data Exchange (ETDEWEB)

    Bazalova-Carter, Magdalena; Liu, Michael; Palma, Bianey; Koong, Albert C.; Maxim, Peter G., E-mail: Peter.Maxim@Stanford.edu, E-mail: BWLoo@Stanford.edu; Loo, Billy W., E-mail: Peter.Maxim@Stanford.edu, E-mail: BWLoo@Stanford.edu [Department of Radiation Oncology, Stanford University, Stanford, California 94305-5847 (United States); Dunning, Michael; McCormick, Doug; Hemsing, Erik; Nelson, Janice; Jobe, Keith; Colby, Eric; Tantawi, Sami; Dolgashev, Valery [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States)

    2015-04-15

    Purpose: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. Methods: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0–6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. Results: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4–6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0–4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. Conclusions: The authors demonstrate that relative dose distributions for VHEE beams of 50–70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.

  4. High-Dose-Rate Brachytherapy as Monotherapy Delivered in Two Fractions Within One Day for Favorable/Intermediate-Risk Prostate Cancer: Preliminary Toxicity Data

    Energy Technology Data Exchange (ETDEWEB)

    Ghilezan, Michel, E-mail: mghilezan@beaumont.edu [Department of Radiation Oncology, William Beaumont Hospital and Rose Cancer Institute, Royal Oak, Michigan (United States); Martinez, Alvaro; Gustason, Gary; Krauss, Daniel; Antonucci, J. Vito; Chen, Peter; Fontanesi, James; Wallace, Michelle; Ye Hong; Casey, Alyse; Sebastian, Evelyn; Kim, Leonard; Limbacher, Amy [Department of Radiation Oncology, William Beaumont Hospital and Rose Cancer Institute, Royal Oak, Michigan (United States)

    2012-07-01

    Purpose: To report the toxicity profile of high-dose-rate (HDR)-brachytherapy (BT) as monotherapy in a Human Investigation Committee-approved study consisting of a single implant and two fractions (12 Gy Multiplication-Sign 2) for a total dose of 24 Gy, delivered within 1 day. The dose was subsequently increased to 27 Gy (13.5 Gy Multiplication-Sign 2) delivered in 1 day. We report the acute and early chronic genitourinary and gastrointestinal toxicity. Methods and Materials: A total of 173 patients were treated between December 2005 and July 2010. However, only the first 100 were part of the IRB-approved study and out of these, only 94 had a minimal follow-up of 6 months, representing the study population for this preliminary report. All patients had clinical Stage T2b or less (American Joint Committee on Cancer, 5th edition), Gleason score 6-7 (3+4), and prostate-specific antigen level of {<=}12 ng/mL. Ultrasound-guided HDR-BT with real-time dosimetry was used. The prescription dose was 24 Gy for the first 50 patients and 27 Gy thereafter. The dosimetric goals and constraints were the same for the two dose groups. Toxicity was scored using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. The highest toxicity scores encountered at any point during follow-up are reported. Results: The median follow-up was 17 months (range, 6-40.5). Most patients had Grade 0-1 acute toxicity. The Grade 2 acute genitourinary toxicity was mainly frequency/urgency (13%), dysuria (5%), hematuria, and dribbling/hesitancy (2%). None of the patients required a Foley catheter at any time; however, 8% of the patients experienced transient Grade 1 diarrhea. No other acute gastrointestinal toxicities were found. The most common chronic toxicity was Grade 2 urinary frequency/urgency in 16% of patients followed by dysuria in 4% of patients; 2 patients had Grade 2 rectal bleeding and 1 had Grade 4, requiring laser treatment. Conclusions: Favorable

  5. Electronic compensation technique to deliver a total body dose

    Science.gov (United States)

    Lakeman, Tara E.

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient's immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has been conventionally used to compensate for the varying thickness throughout the body in large-field TBI. The goal of this study is to pursue utilizing the modern electronic compensation technique to more accurately and efficiently deliver dose to patients in need of TBI. Method: Treatment plans utilizing the electronic compensation to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Each treatment plan includes two pair of parallel opposed fields. One pair of large fields is used to encompass the majority of the patient's anatomy. The other pair are very small open fields focused only on the thin bottom portion of the patient's anatomy, which requires much less radiation than the rest of the body to reach 100% of the prescribed dose. A desirable fluence pattern was manually painted within each of the larger fields for each patient to provide a more uniform distribution. Results: Dose-volume histograms (DVH) were calculated for evaluating the electronic compensation technique. In the electronically compensated plans, the maximum body doses calculated from the DVH were reduced from the conventionally-compensated plans by an average of 15%, indicating a more uniform dose. The mean body doses calculated from the electronically compensated DVH remained comparable to that of the conventionally-compensated plans, indicating an accurate delivery of the prescription dose using electronic compensation. All calculated monitor units were within clinically acceptable limits. Conclusion: Electronic compensation technique for TBI will not increase the beam on time beyond clinically acceptable limits while it can substantially reduce the compensator setup

  6. LESM: a laser-driven sub-MeV electron source delivering ultra-high dose rate on thin biological samples

    Science.gov (United States)

    Labate, L.; Andreassi, M. G.; Baffigi, F.; Bizzarri, R.; Borghini, A.; Bussolino, G. C.; Fulgentini, L.; Ghetti, F.; Giulietti, A.; Köster, P.; Lamia, D.; Levato, T.; Oishi, Y.; Pulignani, S.; Russo, G.; Sgarbossa, A.; Gizzi, L. A.

    2016-07-01

    We present a laser-driven source of electron bunches with average energy 260~\\text{keV} and picosecond duration, which has been setup for radiobiological tests covering the previously untested sub-MeV energy range. Each bunch combines high charge with short duration and sub-millimeter range into a record instantaneous dose rate, as high as {{10}9}~\\text{Gy}~{{\\text{s}}-1} . The source can be operated at 10~\\text{Hz} and its average dose rate is 35~\\text{mGy}~{{\\text{s}}-1} . Both the high instantaneous dose rate and high level of relative biological effectiveness, attached to sub-MeV electrons, make this source very attractive for studies of ultrafast radiobiology on thin cell samples. The source reliability, in terms of shot-to-shot stability of features such as mean energy, bunch charge and transverse beam profile, is discussed, along with a dosimetric characterization. Finally, a few preliminary biological tests performed with this source are presented.

  7. Variability in delivered dose and respirable delivered dose from nebulizers: are current regulatory testing guidelines sufficient to produce meaningful information?

    Science.gov (United States)

    Hatley, Ross HM; Byrne, Sarah M

    2017-01-01

    Background To improve convenience to patients, there have been advances in the operation of nebulizers, resulting in fast treatment times and less drug lost to the environment. However, limited attention has been paid to the effects of these developments on the delivered dose (DD) and respirable delivered dose (RDD). Published pharmacopoeia and ISO testing guidelines for adult-use testing utilize a single breathing pattern, which may not be sufficient to enable effective comparisons between the devices. Materials and methods The DD of 5 mg of salbutamol sulfate into adult breathing patterns with inhalation:exhalation (I:E) ratios between 1:1 and 1:4 was determined. Droplet size was determined by laser diffraction and RDD calculated. Nine different nebulizer brands with different modes of operation (conventional, venturi, breath-enhanced, mesh, and breath-activated) were tested. Results Between the non-breath-activated nebulizers, a 2.5-fold difference in DD (~750–1,900 µg salbutamol) was found; with RDD, there was a more than fourfold difference (~210–980 µg). With increasing time spent on exhalation, there were progressive reductions in DD and RDD, with the RDD at an I:E ratio of 1:4 being as little as 40% of the dose with the 1:1 I:E ratio. The DD and RDD from the breath-activated mesh nebulizer were independent of the I:E ratio, and for the breath-activated jet nebulizer, there was less than 20% change in RDD between the I:E ratios of 1:1 and 1:4. Conclusion Comparing nebulizers using the I:E ratio recommended in the guidelines does not predict relative performance between the devices at other ratios. There was significant variance in DD or RDD between different brands of non-breath-activated nebulizer. In future, consideration should be given to revision of the test protocols included in the guidelines, to reflect more accurately the potential therapeutic dose that is delivered to a realistic spectrum of breathing patterns. PMID:28203110

  8. Influence of carrier cells on the clinical outcome of children with neuroblastoma treated with high dose of oncolytic adenovirus delivered in mesenchymal stem cells.

    Science.gov (United States)

    Melen, Gustavo J; Franco-Luzón, Lidia; Ruano, David; González-Murillo, África; Alfranca, Arantzazu; Casco, Fernando; Lassaletta, Álvaro; Alonso, Mercedes; Madero, Luís; Alemany, Ramón; García-Castro, Javier; Ramírez, Manuel

    2016-02-28

    We report here our clinical experience of a program of compassionate use of Celyvir--autologous marrow-derived mesenchymal stem cells (MSCs) carrying an oncolytic adenovirus--for treating children with advanced metastatic neuroblastoma. Children received weekly doses of Celyvir with no concomitant treatments. The tolerance was excellent, with very mild and self-limited viral-related symptoms. Patients could be distinguished based on their response to therapy: those who had a clinical response (either complete, partial or stabilization) and those who did not respond. We found differences between patients who responded versus those who did not when analyzing their respective MSCs, at the expression levels of adhesion molecules (CCR1, CXCR1 and CXCR4) and in migration capacities in transwell assays, and in immune-related molecules (IFNγ, HLA-DR). These results suggest interpatient differences in the homing and immune modulation capacities of the therapy administered. In addition, the pretherapy immune T cell status and the T effector response were markedly different between responders and non-responders. We conclude that multidoses of Celyvir have an excellent safety profile in children with metastatic neuroblastoma. Intrinsic patients' and MSCs' factors appear to be related to clinical outcome.

  9. Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions

    Energy Technology Data Exchange (ETDEWEB)

    Zeng Chuan; Giantsoudi, Drosoula; Grassberger, Clemens; Goldberg, Saveli; Niemierko, Andrzej; Paganetti, Harald; Efstathiou, Jason A.; Trofimov, Alexei [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States)

    2013-05-15

    Purpose: Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. Methods: For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor

  10. Uncertainty in delivered dose resulting from the distribution of source activities in a Selectron LDR afterloader

    Energy Technology Data Exchange (ETDEWEB)

    Ho, A.K.; Castiglione, Robert; Podgorsak, M.B.; Sibata, C.H.; Shin, K.H. (Roswell Park Cancer Inst., Buffalo, NY (United States). Dept. of Radiation Medicine)

    1994-11-01

    The uncertainty in the delivered dose resulting from the distribution of [sup 137]Cs source activity in a clinical Selectron LDR unit has been studied. A comparison is made of the dose delivered to a point 'A' in an implant with sources of equal activity to the actual dose delivered in the same implant with source activities randomly chosen from the population in the afterloader. (author).

  11. Variable dose rate single-arc IMAT delivered with a constant dose rate and variable angular spacing.

    Science.gov (United States)

    Tang, Grace; Earl, Matthew A; Yu, Cedric X

    2009-11-07

    Single-arc intensity-modulated arc therapy (IMAT) has gained worldwide interest in both research and clinical implementation due to its superior plan quality and delivery efficiency. Single-arc IMAT techniques such as the Varian RapidArc deliver conformal dose distributions to the target in one single gantry rotation, resulting in a delivery time in the order of 2 min. The segments in these techniques are evenly distributed within an arc and are allowed to have different monitor unit (MU) weightings. Therefore, a variable dose-rate (VDR) is required for delivery. Because the VDR requirement complicates the control hardware and software of the linear accelerators (linacs) and prevents most existing linacs from delivering IMAT, we propose an alternative planning approach for IMAT using constant dose-rate (CDR) delivery with variable angular spacing. We prove the equivalence by converting VDR-optimized RapidArc plans to CDR plans, where the evenly spaced beams in the VDR plan are redistributed to uneven spacing such that the segments with larger MU weighting occupy a greater angular interval. To minimize perturbation in the optimized dose distribution, the angular deviation of the segments was restricted to single gantry sweep as in the VDR plans but each sector was delivered with a different value of CDR. For four patient cases, including two head-and-neck, one brain and one prostate, all CDR plans developed with the variable spacing scheme produced similar dose distributions to the original VDR plans. For plans with complex angular MU distributions, the number of sectors increased up to four in the CDR plans in order to maintain the original plan quality. Since each sector was delivered with a different dose rate, extra mode-up time (xMOT) was needed between the transitions of the successive sectors during delivery. On average, the delivery times of the CDR plans were approximately less than 1 min longer than the treatment times of the VDR plans, with an average of

  12. Quantifying radiation dose delivered to individual shoulder muscles during breast radiotherapy.

    Science.gov (United States)

    Lipps, David B; Sachdev, Sean; Strauss, Jonathan B

    2017-03-01

    Radiotherapy is an effective treatment for managing breast cancer, but patients may experience shoulder morbidity after completing radiotherapy. There is a knowledge gap regarding how the inclusion of the regional lymphatics in radiation treatment regimens influence the radiation dose delivered to the underlying shoulder musculature. Five standardized radiation treatment regimens were developed from the computed tomography (CT) scans of 11 patients: tangent fields only (T), high tangent fields (HT), T+supraclavicular fossa and axillary apex with an anterior oblique beam (SCV), T+SCV+axillary nodes with an anterior oblique beam (SCV+AX), and T+SCV+AX with the nodal regions treated with a directly opposed beam configuration (DO). The muscle volumes for nine shoulder muscles anatomically located with the treatment regimens were segmented from the same CT scans. The effect of the nine muscles and five treatment regimens on the percentage of each muscle receiving at least 48Gy (V48Gy) was analyzed with two-way and one-way repeated measures ANOVAs. A statistically significant interaction existed between the nine shoulder muscles and five treatment regimens (pmuscle (pmuscles (pectoralis major, pectoralis minor, latissimus dorsi, and teres major) that may exhibit future morbidity after radiation, and indicate that nodal RT delivered with a DO beam arrangement delivers the highest muscle dose. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Planning and delivering high doses to targets surrounding the spinal cord at the lower neck and upper mediastinal levels: static beam-segmentation technique executed by a multileaf collimator

    Energy Technology Data Exchange (ETDEWEB)

    Schelfhout, J.; Derycke, S.; Fortan, L.; Van Duyse, B.; Colle, C.; De Wagter, C.; De Neve, W. [Ghent Rijksuniversiteit (Belgium). Kliniek voor Radiotherapie en Kerngeneeskunde

    1995-12-01

    The possibility to plan and deliver beam intensity modulated radiotherapy using a general purpose 3D-planning system (Sherouse`s GRATISTM) and a linear accelerator equipped with a standard multileaf collimator (MLC) was investigated in view of limiting the dose at the spinal cord below tolerance. During the planning process, dose homogenization at the target is obtained by the calculation of the weights, given to beam segments of a specific predetermined geometry. This specific geometry maximizes the area of each segment and thus reduces the number of segments. With a virtual patient in supine position, a first planning using a single isocenter, with gantry positions of -60, -30, 0, 30 and 60 degrees was performed. Medial edges of all segments were located tangential to the spinal cord. The resulting dose distribution allowed to encompass the target by an isodose surface of 66-70 Gy without exceeding spinal cord tolerance but required 42 segments distributed over 5 gantry angles. Therefore, dose-volume histogram analysis were performed for those cases where: (1) for some gantry positions, all beam segments could be omitted; (2) at the remaining gantry angles, segments could be omitted; (3) at least 2 segments could be traded off against 1 additional gantry angle. This procedure resulted in a final plan containing 22 segments spread over 8 gantry angles. Preliminary dosimetric results on a RANDO phantom support the robustness of the method. The first clinical applications have been planned. Although up to 99 beam segments can be programmed on the Philips SL25 linear accelerator, it remained impossible to use these segments synchronized with the MLC. From a clinical viewpoint, the proposed treatment for irradiating lower neck and upper mediastinal targets could be used as a standard against which other solutions might be tested.

  14. Determination of the delivered hemodialysis dose using standard methods and on-line clearance monitoring

    Directory of Open Access Journals (Sweden)

    Vlatković Vlastimir

    2006-01-01

    Full Text Available Background/aim: Delivered dialysis dose has a cumulative effect and significant influence upon the adequacy of dialysis, quality of life and development of co-morbidity at patients on dialysis. Thus, a great attention is given to the optimization of dialysis treatment. On-line Clearance Monitoring (OCM allows a precise and continuous measurement of the delivered dialysis dose. Kt/V index (K = dialyzer clearance of urea; t = dialysis time; V = patient's total body water, measured in real time is used as a unit for expressing the dialysis dose. The aim of this research was to perform a comparative assessment of the delivered dialysis dose by the application of the standard measurement methods and a module for continuous clearance monitoring. Methods. The study encompassed 105 patients who had been on the chronic hemodialysis program for more than three months, three times a week. By random choice, one treatment per each controlled patient was taken. All the treatments understood bicarbonate dialysis. The delivered dialysis dose was determined by the calculation of mathematical models: Urea Reduction Ratio (URR singlepool index Kt/V (spKt/V and by the application of OCM. Results. Urea Reduction Ratio was the most sensitive parameter for the assessment and, at the same time, it was in the strongest correlation with the other two, spKt/V indexes and OCM. The values pointed out an adequate dialysis dose. The URR values were significantly higher in women than in men, p < 0.05. The other applied model for the delivered dialysis dose measurement was Kt/V index. The obtained values showed that the dialysis dose was adequate, and that, according to this parameter, the women had significantly better dialysis, then the men p < 0.05. According to the OCM, the average value was slightly lower than the adequate one. The women had a satisfactory dialysis according to this index as well, while the delivered dialysis dose was insufficient in men. The difference

  15. Prospective Study Delivering Simultaneous Integrated High-dose Tumor Boost (≤70 Gy) With Image Guided Adaptive Radiation Therapy for Radical Treatment of Localized Muscle-Invasive Bladder Cancer.

    Science.gov (United States)

    Hafeez, Shaista; Warren-Oseni, Karole; McNair, Helen A; Hansen, Vibeke N; Jones, Kelly; Tan, Melissa; Khan, Attia; Harris, Victoria; McDonald, Fiona; Lalondrelle, Susan; Mohammed, Kabir; Thomas, Karen; Thompson, Alan; Kumar, Pardeep; Dearnaley, David; Horwich, Alan; Huddart, Robert

    2016-04-01

    Image guided adaptive radiation therapy offers individualized solutions to improve target coverage and reduce normal tissue irradiation, allowing the opportunity to increase the radiation tumor dose and spare normal bladder tissue. A library of 3 intensity modulated radiation therapy plans were created (small, medium, and large) from planning computed tomography (CT) scans performed at 30 and 60 minutes; treating the whole bladder to 52 Gy and the tumor to 70 Gy in 32 fractions. A "plan of the day" approach was used for treatment delivery. A post-treatment cone beam CT (CBCT) scan was acquired weekly to assess intrafraction filling and coverage. A total of 18 patients completed treatment to 70 Gy. The plan and treatment for 1 patient was to 68 Gy. Also, 1 patient's plan was to 70 Gy but the patient was treated to a total dose of 65.6 Gy because dose-limiting toxicity occurred before dose escalation. A total of 734 CBCT scans were evaluated. Small, medium, and large plans were used in 36%, 48%, and 16% of cases, respectively. The mean ± standard deviation rate of intrafraction filling at the start of treatment (ie, week 1) was 4.0 ± 4.8 mL/min (range 0.1-19.4) and at end of radiation therapy (ie, week 5 or 6) was 1.1 ± 1.6 mL/min (range 0.01-7.5; P=.002). The mean D98 (dose received by 98% volume) of the tumor boost and bladder as assessed on the post-treatment CBCT scan was 97.07% ± 2.10% (range 89.0%-104%) and 99.97% ± 2.62% (range 96.4%-112.0%). At a median follow-up period of 19 months (range 4-33), no muscle-invasive recurrences had developed. Two patients experienced late toxicity (both grade 3 cystitis) at 5.3 months (now resolved) and 18 months after radiation therapy. Image guided adaptive radiation therapy using intensity modulated radiation therapy to deliver a simultaneous integrated tumor boost to 70 Gy is feasible, with acceptable toxicity, and will be evaluated in a randomized trial. Copyright © 2016 The Authors. Published by Elsevier Inc. All

  16. Delivering Training for Highly Demanding Information Systems

    Science.gov (United States)

    Norton, Andrew Lawrence; Coulson-Thomas, Yvette May; Coulson-Thomas, Colin Joseph; Ashurst, Colin

    2012-01-01

    Purpose: There is a lack of research covering the training requirements of organisations implementing highly demanding information systems (HDISs). The aim of this paper is to help in the understanding of appropriate training requirements for such systems. Design/methodology/approach: This research investigates the training delivery within a…

  17. 3D delivered dose assessment using a 4DCT-based motion model

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Weixing; Hurwitz, Martina H.; Williams, Christopher L.; Dhou, Salam; Berbeco, Ross I.; Mishra, Pankaj, E-mail: wcai@lroc.harvard.edu, E-mail: jhlewis@lroc.harvard.edu; Lewis, John H., E-mail: wcai@lroc.harvard.edu, E-mail: jhlewis@lroc.harvard.edu [Brigham and Women’s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts 02115 (United States); Seco, Joao [Francis H. Burr Proton Therapy Center, Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2015-06-15

    Purpose: The purpose of this work is to develop a clinically feasible method of calculating actual delivered dose distributions for patients who have significant respiratory motion during the course of stereotactic body radiation therapy (SBRT). Methods: A novel approach was proposed to calculate the actual delivered dose distribution for SBRT lung treatment. This approach can be specified in three steps. (1) At the treatment planning stage, a patient-specific motion model is created from planning 4DCT data. This model assumes that the displacement vector field (DVF) of any respiratory motion deformation can be described as a linear combination of some basis DVFs. (2) During the treatment procedure, 2D time-varying projection images (either kV or MV projections) are acquired, from which time-varying “fluoroscopic” 3D images of the patient are reconstructed using the motion model. The DVF of each timepoint in the time-varying reconstruction is an optimized linear combination of basis DVFs such that the 2D projection of the 3D volume at this timepoint matches the projection image. (3) 3D dose distribution is computed for each timepoint in the set of 3D reconstructed fluoroscopic images, from which the total effective 3D delivered dose is calculated by accumulating deformed dose distributions. This approach was first validated using two modified digital extended cardio-torso (XCAT) phantoms with lung tumors and different respiratory motions. The estimated doses were compared to the dose that would be calculated for routine 4DCT-based planning and to the actual delivered dose that was calculated using “ground truth” XCAT phantoms at all timepoints. The approach was also tested using one set of patient data, which demonstrated the application of our method in a clinical scenario. Results: For the first XCAT phantom that has a mostly regular breathing pattern, the errors in 95% volume dose (D95) are 0.11% and 0.83%, respectively for 3D fluoroscopic images

  18. Measurements of the dose delivered during CT exams using AAPM Task Group Report No. 111.

    Science.gov (United States)

    Descamps, Caroline; Gonzalez, Mercedes; Garrigo, Edgardo; Germanier, Alejandro; Venencia, Daniel

    2012-11-08

    The computed tomography dose index (CTDI) measured with a 10 cm long pencil ionization chamber placed in a 14 cm long PMMA phantom is typically used to evaluate the doses delivered during CT procedure. For the new generation of CT scanners, the efficiency of this methodology is low because it excludes the contribution of radiation scattered beyond the 100 mm range of integration along z. The AAPM TG111 Report proposes a new measurement modality using a small volume ionization chamber positioned in a phantom long enough to establish dose equilibrium at the location of the chamber. In this work, the AAPM report was implemented. The minimum scanning length needed to obtain cumulative dose equilibrium was evaluated. The equilibrium dose was determined and compared to CTDI values informed by the CT scanner, and the dose values were confirmed with TLD measurements. The difference between doses measured with TLD and with the ionization chamber (IC) was below 1% and the repeatability of the measurements' setup was 0.4%. The measurements showed that the scanning lengths needed to reach the cumulated dose equilibrium were 450 mm and 380 mm for the central and peripheral axes, respectively, which justifies the phantom length. For the studied clinical protocols, the doses measured were about 30% higher than those informed by the CT scanner. For the new generation of CT systems with wider longitudinal detector size or cone-beam technology, the current CTDI measurements may no longer be adequate, and the informed CTDI tends to undervalue the dose delivered. It is therefore important to evaluate CT radiation doses following the AAPM TG111 methodology.

  19. Improvements in dose accuracy delivered with static-MLC IMRT on an integrated linear accelerator control system

    Energy Technology Data Exchange (ETDEWEB)

    Li Ji; Wiersma, Rodney D.; Stepaniak, Christopher J.; Farrey, Karl J.; Al-Hallaq, Hania A. [Department of Radiation and Cellular Oncology, University of Chicago, 5758 South Maryland Avenue, MC9006, Chicago, Illinois 60637 (United States)

    2012-05-15

    Trilogy and the TrueBeam up to 10 MU/segment, at all dose rates greater than 100 MU/min. The linear trend of decreasing dose accuracy as a function of increasing dose rate on the Trilogy is no longer apparent on TrueBeam, even for dose rates as high as 2400 MU/min. Dose inaccuracy averaged over all ten segments in each beam delivery sequence was larger for Trilogy than TrueBeam, with the largest discrepancy (0.2% vs 3%) occurring for 1 MU/segment beams at both 300 and 600 MU/min. Conclusions: Earlier generations of Varian LINACs exhibited large dose variations for small MU segments in SMLC-IMRT delivery. Our results confirmed these findings. The dose delivery accuracy for SMLC-IMRT is significantly improved on TrueBeam compared to Trilogy for every combination of low MU/segment (1-10) and high dose rate (200-600 MU/min), in part due to the faster sampling rate (100 vs 20 Hz) and enhanced electronic integration of the MLC controller with the LINAC. SMLC-IMRT can be implemented on TrueBeam with higher dose accuracy per beam ({+-}0.2% vs {+-}3%) than previous generations of Varian C-series LINACs for 1 MU/segment delivered at 600 MU/min).

  20. Evaluation of Rectal Dose During High-Dose-Rate Intracavitary Brachytherapy for Cervical Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Sha, Rajib Lochan [Department of Radiation Physics, Indo-American Cancer Institute and Research Centre, Hyderabad (India); Department of Physics, Osmania University, Hyderabad (India); Reddy, Palreddy Yadagiri [Department of Physics, Osmania University, Hyderabad (India); Rao, Ramakrishna [Department of Radiation Physics, MNJ Institute of Oncology and Regional Cancer Center, Hyderabad (India); Muralidhar, Kanaparthy R. [Department of Radiation Physics, Indo-American Cancer Institute and Research Centre, Hyderabad (India); Kudchadker, Rajat J., E-mail: rkudchad@mdanderson.org [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States)

    2011-01-01

    High-dose-rate intracavitary brachytherapy (HDR-ICBT) for carcinoma of the uterine cervix often results in high doses being delivered to surrounding organs at risk (OARs) such as the rectum and bladder. Therefore, it is important to accurately determine and closely monitor the dose delivered to these OARs. In this study, we measured the dose delivered to the rectum by intracavitary applications and compared this measured dose to the International Commission on Radiation Units and Measurements rectal reference point dose calculated by the treatment planning system (TPS). To measure the dose, we inserted a miniature (0.1 cm{sup 3}) ionization chamber into the rectum of 86 patients undergoing radiation therapy for cervical carcinoma. The response of the miniature chamber modified by 3 thin lead marker rings for identification purposes during imaging was also characterized. The difference between the TPS-calculated maximum dose and the measured dose was <5% in 52 patients, 5-10% in 26 patients, and 10-14% in 8 patients. The TPS-calculated maximum dose was typically higher than the measured dose. Our study indicates that it is possible to measure the rectal dose for cervical carcinoma patients undergoing HDR-ICBT. We also conclude that the dose delivered to the rectum can be reasonably predicted by the TPS-calculated dose.

  1. SU-E-T-357: Electronic Compensation Technique to Deliver Total Body Dose

    Energy Technology Data Exchange (ETDEWEB)

    Lakeman, T [State University of New York at Buffalo, Buffalo, NY (United States); Wang, I; Podgorsak, M [State University of New York at Buffalo, Buffalo, NY (United States); Roswell Park Cancer Institute, Buffalo, NY (United States)

    2015-06-15

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient’s immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has conventionally been used to compensate for the varying thickness through the entire body in large-field TBI. The goal of this study is to pursue utilizing the modern electronic compensation technique to more accurately and efficiently deliver dose to patients in need of TBI. Methods: Treatment plans utilizing electronic compensation to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Each treatment plan includes two, specifically weighted, pair of opposed fields. One pair of open, large fields (collimator=45°), to encompass the patient’s entire anatomy, and one pair of smaller fields (collimator=0°) focused only on the thicker midsection of the patient. The optimal fluence for each one of the smaller fields was calculated at a patient specific penetration depth. Irregular surface compensators provide a more uniform dose distribution within the smaller opposed fields. Results: Dose-volume histograms (DVH) were calculated for the evaluating the electronic compensation technique. In one case, the maximum body doses calculated from the DVH were reduced from the non-compensated 195.8% to 165.3% in the electronically compensated plans, indicating a more uniform dose with the region of electronic compensation. The mean body doses calculated from the DVH were also reduced from the non-compensated 120.6% to 112.7% in the electronically compensated plans, indicating a more accurate delivery of the prescription dose. All calculated monitor units were well within clinically acceptable limits. Conclusion: Electronic compensation technique for TBI will not substantially increase the beam on time while it can significantly reduce the compensator

  2. Dose delivered from Varian's CBCT to patients receiving IMRT for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Wen Ning; Guan Huaiqun; Hammoud, Rabih; Pradhan, Deepak; Nurushev, T; Li Shidong; Movsas, Benjamin [Henry Ford Health System, Detroit, MI (United States)

    2007-04-21

    With the increased use of cone beam CT (CBCT) for daily patient setup, the accumulated dose from CBCT may be significantly higher than that from simulation CT or portal imaging. The objective of this work is to measure the dose from daily pelvic scans with fixed technical settings and collimations. CBCT scans were acquired in half-fan mode using a half bowtie and x-rays were delivered in pulsed-fluoro mode. The skin doses for seven prostate patients were measured on an IRB-approved protocol. TLD capsules were placed on the patient's skin at the central axis of three beams: AP, left lateral (Lt Lat) and right lateral (Rt Lat). To avoid the ring artefacts centred in the prostate, the treatment couch was dropped 3 cm from the patient's tattoo (central axis). The measured AP skin doses ranged 3-6 cGy for 20-33 cm separation. The larger the patient size the less the AP skin dose. Lateral doses did not change much with patient size. The Lt Lat dose was {approx}4.0 cGy, which was {approx}40% higher than the Rt Lat dose of {approx}2.6 cGy. To verify this dose asymmetry, surface doses on an IMRT QA phantom (oval shaped, 30 cm x 20 cm) were measured at the same three sites using TLD capsules with 3 cm table-drop. The dose asymmetry was due to: (1) kV source rotation which always starts from the patient's Lt Lat and ends at Lt Lat. Gantry rotation gets much slower near the end of rotation but dose rate stays constant and (2) 370{sup 0} scan rotation (10{sup 0} scan overlap on the Lt Lat side). In vivo doses were measured inside a Rando pelvic heterogeneous phantom using TLDs. The left hip (femoral head and neck) received the highest doses of {approx}10-11 cGy while the right hip received {approx}6-7 cGy. The surface and in vivo doses were also measured for phantoms at the central-axis setup. The difference was less than {approx}12% to the table-drop setup.

  3. Should we routinely remove the dose delivered by the images of control?; Faut-il systematiquement retirer la dose delivree par les images de controle?

    Energy Technology Data Exchange (ETDEWEB)

    Goasduff, G. [Centre Hospitalier Universitaire Morvan, Service de Radiotherapie, 29 - Brest (France); Pene Baverez, D.; Pradier, O.; Bouchekoua, M. [Service de Radiotherapie, 29 - Brest (France)

    2009-10-15

    The constraints of doses fixed by the international commission on radiation units and measurements (ICRU) for the target volume (95-107% of the prescribed dose) are respected. for the hypo fractionated treatments, it is necessary to control the impact of the dose delivered by the control images for every patient. The dose delivered at the isocenter is estimated between 1 and 3 Gy by control image: this dose depends on the beams size and on the distance-source-skin. Protocols of the patient positioning checking must be implemented on optimizing their frequency to limit the dose received by the patient. (N.C.)

  4. The impact of modeling nuclear fragmentation on delivered dose and radiobiology in ion therapy.

    Science.gov (United States)

    Lühr, Armin; Hansen, David C; Teiwes, Ricky; Sobolevsky, Nikolai; Jäkel, Oliver; Bassler, Niels

    2012-08-21

    The importance of nuclear interactions for ion therapy arises from the influence of the particle spectrum on, first, radiobiology and therefore also on treatment planning, second, the accuracy of measuring dose and, third, the delivered dose distribution. This study tries to determine the qualitative as well as the quantitative influence of the modeling of inelastic nuclear interactions on ion therapy. Thereby, three key disciplines are investigated, namely dose delivery, dose assessment and radiobiology. In order to perform a quantitative analysis, a relative comparison between six different descriptions of nuclear interactions is carried out for carbon ions. The particle transport is simulated with the Monte Carlo code SHIELD-HIT10A while dose planning and radiobiology are covered by the analytic treatment planning program for particles TRiP, which determines the relative biological effectiveness (RBE) with the local effect model. The obtained results show that the physical dose distribution can in principle be significantly influenced by the modeling of fragmentation (about 10% for a 20% change in all inelastic nuclear cross sections for a target volume ranging from 15 to 25 cm). While the impact of nuclear fragmentation on stopping power ratios can be neglected, the fluence correction factor may be influenced by the applied nuclear models. In contrast to the results for the physical dose, the variation of the RBE is only small (about 1% for a 20% change in all inelastic nuclear cross sections) suggesting a relatively weak dependence of radiobiology on the detailed composition of the particle energy spectrum of the mixed radiation field. Also, no significant change (about 0.2 mm) of the lateral penumbra of the RBE-weighted dose is observed.

  5. Doses delivered to normal brain under different treatment protocols at Brookhaven National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Capala, J.; Coderre, J.A.; Liu, H.B. [and others

    1996-12-31

    As of October 31, 1996, 23 glioblastoma multiforme patients underwent BNCT under several treatment protocols at the Brookhaven Medical Research Reactor. For treatment planning and dosimetry purposes, these protocols may be divided into four groups. The first group comprises protocols that used an 8-cm collimator and allowed a peak normal brain dose of 10.5 Gy-Eq to avolume of 1 cm{sup 3} were the thermal neutron flux was maximal (even if it happened to be in the tumor volume). The second group differs from the first in that it allowed a peak normal brain dose of 12.6 Gy-Eq. The protocols of the third and fourth groups allowed the prescribed peak normal brain dose of 12.6 Gy-Eq to be outside of the tumor volume, used a 12-cm collimator and, respectively, uni- or bilateral irradiations. We describe the treatment planning procedures and report the doses delivered to various structures of the brain.

  6. Combined magnetic resonance urography and targeted helical CT in patients with renal colic: a new approach to reduce delivered dose.

    Science.gov (United States)

    Blandino, Alfredo; Minutoli, Fabio; Scribano, Emanuele; Vinci, Sergio; Magno, Carlo; Pergolizzi, Stefano; Settineri, Nicola; Pandolfo, Ignazio; Gaeta, Michele

    2004-08-01

    To determine whether magnetic resonance urography (MRU), obtained before helical computed tomography (CT) in patients with acute renal colic, can help delimit the obstructed area to be subsequently examined by a targeted CT scan, thus reducing the dose of radiation. Patients (51) with symptoms of acute renal colic underwent MRU and a total urinary tract helical CT. CT images from the 5 cm below the level of ureteral obstruction as demonstrated by MRU were selected out. Combined interpretation of MRU and selected CT images constituted protocol A. Protocol B consisted of the entire unenhanced helical CT of the urinary tract. The two protocols were compared regarding the following points: 1) sensitivity in diagnosing the presence of obstructing urinary stones, and 2) the delivered radiation dose. Protocol A and protocol B had, respectively, 98% and 100% sensitivity in demonstrating ureteral stone as a cause of renal colic. Estimated average dose calculated from phantom study was 0.52 mSv for protocol A and 2.83 mSv for protocol B. Therefore, the effective radiation dose was 5.4 times lower in protocol A compared to protocol B. Combined MRU and short helical CT has a high sensitivity in detecting ureteral calculi with a reduced radiation dose. Copyright 2004 Wiley-Liss, Inc.

  7. SU-E-T-29: A Web Application for GPU-Based Monte Carlo IMRT/VMAT QA with Delivered Dose Verification

    Energy Technology Data Exchange (ETDEWEB)

    Folkerts, M [The University of Texas Southwestern Medical Ctr, Dallas, TX (United States); University of California, San Diego, La Jolla, CA (United States); Graves, Y [University of California, San Diego, La Jolla, CA (United States); Tian, Z; Gu, X; Jia, X; Jiang, S [The University of Texas Southwestern Medical Ctr, Dallas, TX (United States)

    2014-06-01

    Purpose: To enable an existing web application for GPU-based Monte Carlo (MC) 3D dosimetry quality assurance (QA) to compute “delivered dose” from linac logfile data. Methods: We added significant features to an IMRT/VMAT QA web application which is based on existing technologies (HTML5, Python, and Django). This tool interfaces with python, c-code libraries, and command line-based GPU applications to perform a MC-based IMRT/VMAT QA. The web app automates many complicated aspects of interfacing clinical DICOM and logfile data with cutting-edge GPU software to run a MC dose calculation. The resultant web app is powerful, easy to use, and is able to re-compute both plan dose (from DICOM data) and delivered dose (from logfile data). Both dynalog and trajectorylog file formats are supported. Users upload zipped DICOM RP, CT, and RD data and set the expected statistic uncertainty for the MC dose calculation. A 3D gamma index map, 3D dose distribution, gamma histogram, dosimetric statistics, and DVH curves are displayed to the user. Additional the user may upload the delivery logfile data from the linac to compute a 'delivered dose' calculation and corresponding gamma tests. A comprehensive PDF QA report summarizing the results can also be downloaded. Results: We successfully improved a web app for a GPU-based QA tool that consists of logfile parcing, fluence map generation, CT image processing, GPU based MC dose calculation, gamma index calculation, and DVH calculation. The result is an IMRT and VMAT QA tool that conducts an independent dose calculation for a given treatment plan and delivery log file. The system takes both DICOM data and logfile data to compute plan dose and delivered dose respectively. Conclusion: We sucessfully improved a GPU-based MC QA tool to allow for logfile dose calculation. The high efficiency and accessibility will greatly facilitate IMRT and VMAT QA.

  8. Impact of surface curvature on dose delivery in intraoperative high-dose-rate brachytherapy.

    Science.gov (United States)

    Oh, Moonseong; Wang, Zhou; Malhotra, Harish K; Jaggernauth, Wainwright; Podgorsak, Matthew B

    2009-01-01

    In intraoperative high-dose-rate (IOHDR) brachytherapy, a 2-dimensional (2D) geometry is typically used for treatment planning. The assumption of planar geometry may cause serious errors in dose delivery for target surfaces that are, in reality, curved. A study to evaluate the magnitude of these errors in clinical practice was undertaken. Cylindrical phantoms with 6 radii (range: 1.35-12.5 cm) were used to simulate curved treatment geometries. Treatment plans were developed for various planar geometries and were delivered to the cylindrical phantoms using catheters inserted into Freiburg applicators of varying dimension. Dose distributions were measured using radiographic film. In comparison to the treatment plan (for a planar geometry), the doses delivered to prescription points were higher on the concave side of the geometry, up to 15% for the phantom with the smallest radius. On the convex side of the applicator, delivered doses were up to 10% lower for small treated areas (5 catheters). Our measurements have shown inaccuracy in dose delivery when the original planar treatment plan is delivered with a curved applicator. Dose delivery errors arising from the use of planar treatment plans with curved applicators may be significant.

  9. Absolute calibration of the Gamma Knife{sup ®} Perfexion™ and delivered dose verification using EPR/alanine dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Hornbeck, Amaury, E-mail: amauryhornbeck@gmail.com, E-mail: tristan.garcia@cea.fr; Garcia, Tristan, E-mail: amauryhornbeck@gmail.com, E-mail: tristan.garcia@cea.fr [CEA, LIST, Laboratoire National Henri Becquerel, 91191 Gif-sur-Yvette Cedex (France); Cuttat, Marguerite; Jenny, Catherine [Radiotherapy Department, Medical Physics Unit, University Hospital Pitié-Salpêtrière, 75013 Paris (France)

    2014-06-15

    Purpose: Elekta Leksell Gamma Knife{sup ®} (LGK) is a radiotherapy beam machine whose features are not compliant with the international calibration protocols for radiotherapy. In this scope, the Laboratoire National Henri Becquerel and the Pitié-Salpêtrière Hospital decided to conceive a new LKG dose calibration method and to compare it with the currently used one. Furthermore, the accuracy of the dose delivered by the LGK machine was checked using an “end-to-end” test. This study also aims to compare doses delivered by the two latest software versions of the Gammaplan treatment planning system (TPS). Methods: The dosimetric method chosen is the electron paramagnetic resonance (EPR) of alanine. Dose rate (calibration) verification was done without TPS using a spherical phantom. Absolute calibration was done with factors calculated by Monte Carlo simulation (MCNP-X). For “end-to-end” test, irradiations in an anthropomorphic head phantom, close to real treatment conditions, are done using the TPS in order to verify the delivered dose. Results: The comparison of the currently used calibration method with the new one revealed a deviation of +0.8% between the dose rates measured by ion chamber and EPR/alanine. For simple fields configuration (less than 16 mm diameter), the “end-to-end” tests showed out average deviations of −1.7% and −0.9% between the measured dose and the calculated dose by Gammaplan v9 and v10, respectively. Conclusions: This paper shows there is a good agreement between the new calibration method and the currently used one. There is also a good agreement between the calculated and delivered doses especially for Gammaplan v10.

  10. A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity

    Energy Technology Data Exchange (ETDEWEB)

    Yao Rui; Bernard, Damian; Turian, Julius; Abrams, Ross A.; Sensakovic, William; Fung, Henry C.; Chu, James C. H. [Department of Radiation Oncology, Rush University Medical Center, 500 South Paulina Street, Chicago, Illinois 60612 (United States); Sections of Hematology and Stem Cell Transplantation, Division of Hematology/Oncology, Rush University Medical Center, 500 South Paulina Street, Chicago, Illinois 60612 (United States); Department of Radiation Oncology, Rush University Medical Center, 500 South Paulina Street, Chicago, Illinois 60612 (United States)

    2012-04-15

    Purpose: Total body irradiation (TBI) with megavoltage photon beams has been accepted as an important component of management for a number of hematologic malignancies, generally as part of bone marrow conditioning regimens. The purpose of this paper is to present and discuss the authors' TBI technique, which both simplifies the treatment process and improves the treatment quality. Methods: An AP/PA TBI treatment technique to produce uniform dose distributions using sequential collimator reductions during each fraction was implemented, and a sample calculation worksheet is presented. Using this methodology, the dosimetric characteristics of both 6 and 18 MV photon beams, including lung dose under cerrobend blocks was investigated. A method of estimating midplane lung doses based on measured entrance and exit doses was proposed, and the estimated results were compared with measurements. Results: Whole body midplane dose uniformity of {+-}10% was achieved with no more than two collimator-based beam modulations. The proposed model predicted midplane lung doses 5% to 10% higher than the measured doses for 6 and 18 MV beams. The estimated total midplane doses were within {+-}5% of the prescribed midplane dose on average except for the lungs where the doses were 6% to 10% lower than the prescribed dose on average. Conclusions: The proposed TBI technique can achieve dose uniformity within {+-}10%. This technique is easy to implement and does not require complicated dosimetry and/or compensators.

  11. Estimation of Electron Dose Delivered by a 0.4 MeV Accelerator from Bremsstrahlung Dose Measurements

    DEFF Research Database (Denmark)

    Karadjov, A. G.; Hansen, Jørgen-Walther

    1980-01-01

    Determination of a 0.4 MeV electron dose from a bremsstrahlung dose measurement using a converter-detector system is considered. The detector used is a Frickle dosimeter, and the converters are aluminum, copper and lead foils. Optimal converter thickness is ascertained experimentally for each mat...

  12. Parotid Glands Dose–Effect Relationships Based on Their Actually Delivered Doses: Implications for Adaptive Replanning in Radiation Therapy of Head-and-Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, Klaudia U. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Fernandes, Laura L. [Department of Biostatistics, University of Michigan, Ann Arbor, Michigan (United States); Vineberg, Karen A.; McShan, Daniel; Antonuk, Alan E. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Cornwall, Craig [Department of Hospital Dentistry, University of Michigan, Ann Arbor, Michigan (United States); Feng, Mary [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Schipper, Mathew J. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Department of Biostatistics, University of Michigan, Ann Arbor, Michigan (United States); Balter, James M. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Eisbruch, Avraham, E-mail: eisbruch@umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2013-11-15

    Purpose: Doses actually delivered to the parotid glands during radiation therapy often exceed planned doses. We hypothesized that the delivered doses correlate better with parotid salivary output than the planned doses, used in all previous studies, and that determining these correlations will help make decisions regarding adaptive radiation therapy (ART) aimed at reducing the delivered doses. Methods and Materials: In this prospective study, oropharyngeal cancer patients treated definitively with chemoirradiation underwent daily cone-beam computed tomography (CBCT) with clinical setup alignment based on the C2 posterior edge. Parotid glands in the CBCTs were aligned by deformable registration to calculate cumulative delivered doses. Stimulated salivary flow rates were measured separately from each parotid gland pretherapy and periodically posttherapy. Results: Thirty-six parotid glands of 18 patients were analyzed. Average mean planned doses was 32 Gy, and differences from planned to delivered mean gland doses were −4.9 to +8.4 Gy, median difference +2.2 Gy in glands in which delivered doses increased relative to planned. Both planned and delivered mean doses were significantly correlated with posttreatment salivary outputs at almost all posttherapy time points, without statistically significant differences in the correlations. Large dispersions (on average, SD 3.6 Gy) characterized the dose–effect relationships for both. The differences between the cumulative delivered doses and planned doses were evident at first fraction (r=.92, P<.0001) because of complex setup deviations (eg, rotations and neck articulations), uncorrected by the translational clinical alignments. Conclusions: After daily translational setup corrections, differences between planned and delivered doses in most glands were small relative to the SDs of the dose–saliva data, suggesting that ART is not likely to gain measurable salivary output improvement in most cases. These differences were

  13. Influence of a Commercial Lead Apron on Patient Skin Dose Delivered During Oral and Maxillofacial Examinations under Cone Beam Computed Tomography (CBCT).

    Science.gov (United States)

    Schulze, Ralf Kurt Willy; Sazgar, Mahssa; Karle, Heiko; de Las Heras Gala, Hugo

    2017-08-01

    The purpose of this paper is to investigate the impact of a commercial lead apron on patient skin dose delivered during maxillofacial CBCT in five critical regions by means of solid-state-dosimetry. Five anatomical regions (thyroid gland, left and right breast, gonads, back of the phantom torso) in an adult female anthropomorphic phantom were selected for dose measurement by means of the highly sensitive solid-state dosimeter QUART didoSVM. Ten repeated single exposures were assessed for each patient body region for a total of five commercial CBCT devices with and without a lead apron present. Shielded and non-shielded exposures were compared under the paired Wilcoxon test, with absolute and relative differences computed. Reproducibility was expressed as the coefficient of variation (CV) between the 10 repeated assessments. The highest doses observed at skin level were found at the thyroid (mean shielded ± SD: 450.5 ± 346.7 μGy; non-shielded: 339.2 ± 348.8 μGy, p = 0.4922). Shielding resulted in a highly significant (p shielded dose of approximately 35 μGy. Dose reduction was also significantly lower for the back-region (mean: -65%, p shielded situation. Reproducibility was inversely correlated to skin dose (Rspearman = -0.748, p lead apron, which did not shield this region. Dose reduction by means of a commercial lead apron was significant in all other regions, particularly in the region of the female breast.

  14. Effective dose delivered by conventional radiology to Aosta Valley population between 2002 and 2009

    Science.gov (United States)

    Zenone, F; Aimonetto, S; Catuzzo, P; Peruzzo Cornetto, A; Marchisio, P; Natrella, M; Rosanò, A M; Meloni, T; Pasquino, M; Tofani, S

    2012-01-01

    Objective Medical diagnostic procedures can be considered the main man-made source of ionising radiation exposure for the population. Conventional radiography still represents the largest contribution to examination frequency. The present work evaluates procedure frequency and effective dose from the majority of conventional radiology examinations performed at the Radiological Department of Aosta Hospital from 2002 to 2009. Method Effective dose to the patient was evaluated by means of the software PCXMC. Data provided by the radiological information system allowed us to obtain collective effective and per caput dose. Results The biggest contributors to per caput effective dose from conventional radiology are vertebral column, abdomen, chest, pelvis and (limited to females) breast. Vertebral column, pelvis and breast procedures show a significant dose increment in the period of the study. The mean effective dose per inhabitant from conventional radiology increased from 0.131 mSv in 2002 to 0.156 mSv in 2009. Combining these figures with those from our study of effective dose from CT (0.55 mSv in 2002 to 1.03 mSv in 2009), the total mean effective dose per inhabitant increased from 0.68 mSv to 1.19 mSv. The contribution of CT increased from 81% to 87% of the total. In contrast, conventional radiology accounts for 85% of the total number of procedures, but only 13% of the effective dose. Conclusion The study has demonstrated that conventional radiography still represents the biggest contributor to examination frequency in Aosta Valley in 2009. However, the frequency of the main procedures did not change significantly between 2002 and 2009. PMID:21937611

  15. Pharmacokinetically guided dosing of (high-dose) chemotherapeutic agents

    NARCIS (Netherlands)

    Attema-de Jonge, M.E. (Milly Ellen)

    2004-01-01

    Due to variation in drug distribution, metabolism and elimination processes between patients, systemic exposure to chemotherapeutic agents may be highly variable from patient to patient after administration of similar doses. This pharmacokinetic variability may explain in part the large variability

  16. SU-D-201-02: Prediction of Delivered Dose Based On a Joint Histogram of CT and FDG PET Images

    Energy Technology Data Exchange (ETDEWEB)

    Park, M [Brigham and Women’s Hospital and Harvard Medical School, Boston, MA (United States); Choi, Y; Cho, A; Hwang, S; Cha, J; Lee, N; Yun, M [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    Purpose: To investigate whether pre-treatment images can be used in predicting microsphere distribution in tumors. When intra-arterial radioembolization using Y90 microspheres was performed, the microspheres were often delivered non-uniformly within the tumor, which could lead to an inefficient therapy. Therefore, it is important to estimate the distribution of microspheres. Methods: Early arterial phase CT and FDG PET images were acquired for patients with primary liver cancer prior to radioembolization (RE) using Y90 microspheres. Tumor volume was delineated on CT images and fused with FDG PET images. From each voxel (3.9×3.9×3.3 mm3) in the tumor, the Hounsfield unit (HU) from the CT and SUV values from the FDG PET were harvested. We binned both HU and SUV into 11 bins and then calculated a normalized joint-histogram in an 11×11 array.Patients also underwent a post-treatment Y90 PET imaging. Radiation dose for the tumor was estimated using convolution of the Y90 distribution with a dose-point kernel. We also calculated a fraction of the tumor volume that received a radiation dose great than 100Gy. Results: Averaged over 40 patients, 55% of tumor volume received a dose greater than 100Gy (range : 1.1 – 100%). The width of the joint histogram was narrower for patients with a high dose. For patients with a low dose, the width was wider and a larger fraction of tumor volume had low HU. Conclusion: We have shown the pattern of joint histogram of the HU and SUV depends on delivered dose. The patterns can predict the efficacy of uniform intra-arterial delivery of Y90 microspheres.

  17. Forest conservation delivers highly variable coral reef conservation outcomes.

    Science.gov (United States)

    Klein, Carissa J; Jupiter, Stacy D; Selig, Elizabeth R; Watts, Matthew E; Halpern, Benjamin S; Kamal, Muhammad; Roelfsema, Chris; Possingham, Hugh P

    2012-06-01

    Coral reefs are threatened by human activities on both the land (e.g., deforestation) and the sea (e.g., overfishing). Most conservation planning for coral reefs focuses on removing threats in the sea, neglecting management actions on the land. A more integrated approach to coral reef conservation, inclusive of land-sea connections, requires an understanding of how and where terrestrial conservation actions influence reefs. We address this by developing a land-sea planning approach to inform fine-scale spatial management decisions and test it in Fiji. Our aim is to determine where the protection of forest can deliver the greatest return on investment for coral reef ecosystems. To assess the benefits of conservation to coral reefs, we estimate their relative condition as influenced by watershed-based pollution and fishing. We calculate the cost-effectiveness of protecting forest and find that investments deliver rapidly diminishing returns for improvements to relative reef condition. For example, protecting 2% of forest in one area is almost 500 times more beneficial than protecting 2% in another area, making prioritization essential. For the scenarios evaluated, relative coral reef condition could be improved by 8-58% if all remnant forest in Fiji were protected rather than deforested. Finally, we determine the priority of each coral reef for implementing a marine protected area when all remnant forest is protected for conservation. The general results will support decisions made by the Fiji Protected Area Committee as they establish a national protected area network that aims to protect 20% of the land and 30% of the inshore waters by 2020. Although challenges remain, we can inform conservation decisions around the globe by tackling the complex issues relevant to integrated land-sea planning.

  18. SU-E-J-176: Characterization of Inter-Fraction Breast Variability and the Implications On Delivered Dose

    Energy Technology Data Exchange (ETDEWEB)

    Sudhoff, M; Lamba, M; Kumar, N; Ward, A; Elson, H [University of Cincinnati, Cincinnati, OH (United States)

    2015-06-15

    Purpose: To systematically characterize inter-fraction breast variability and determine implications on delivered dose. Methods: Weekly port films were used to characterize breast setup variability. Five evenly spaced representative positions across the contour of each breast were chosen on the electronic port film in reference to graticule, and window and level was set such that the skin surface of the breast was visible. Measurements from the skin surface to treatment field edge were taken on each port film at each position and compared to the planning DRR, quantifying the variability. The systematic measurement technique was repeated for all port films for 20 recently treated breast cancer patients. Measured setup variability for each patient was modeled as a normal distribution. The distribution was randomly sampled from the model and applied as isocentric shifts in the treatment planning computer, representing setup variability for each fraction. Dose was calculated for each shifted fraction and summed to obtain DVHs and BEDs that modeled the dose with daily setup variability. Patients were categorized in to relevant groupings that were chosen to investigate the rigorousness of immobilization types, treatment techniques, and inherent anatomical difficulties. Mean position differences and dosimetric differences were evaluated between planned and delivered doses. Results: The setup variability was found to follow a normal distribution with mean position differences between the DRR and port film between − 8.6–3.5 mm with sigma range of 5.3–9.8 mm. Setup position was not found to be significantly different than zero. The mean seroma or whole breast PTV dosimetric difference, calculated as BED, ranged from a −0.23 to +1.13Gy. Conclusion: A systematic technique to quantify and model setup variability was used to calculate the dose in 20 breast cancer patients including variable setup. No statistically significant PTV or OAR BED differences were found between

  19. Inactivated poliovirus type 2 vaccine delivered to rat skin via high density microprojection array elicits potent neutralising antibody responses.

    Science.gov (United States)

    Muller, David A; Pearson, Frances E; Fernando, Germain J P; Agyei-Yeboah, Christiana; Owens, Nick S; Corrie, Simon R; Crichton, Michael L; Wei, Jonathan C J; Weldon, William C; Oberste, M Steven; Young, Paul R; Kendall, Mark A F

    2016-02-25

    Polio eradication is progressing rapidly, and the live attenuated Sabin strains in the oral poliovirus vaccine (OPV) are being removed sequentially, starting with type 2 in April 2016. For risk mitigation, countries are introducing inactivated poliovirus vaccine (IPV) into routine vaccination programs. After April 2016, monovalent type 2 OPV will be available for type 2 outbreak control. Because the current IPV is not suitable for house-to-house vaccination campaigns (the intramuscular injections require health professionals), we developed a high-density microprojection array, the Nanopatch, delivered monovalent type 2 IPV (IPV2) vaccine to the skin. To assess the immunogenicity of the Nanopatch, we performed a dose-matched study in rats, comparing the immunogenicity of IPV2 delivered by intramuscular injection or Nanopatch immunisation. A single dose of 0.2 D-antigen units of IPV2 elicited protective levels of poliovirus antibodies in 100% of animals. However, animals receiving IPV2 by IM required at least 3 immunisations to reach the same neutralising antibody titres. This level of dose reduction (1/40th of a full dose) is unprecedented for poliovirus vaccine delivery. The ease of administration coupled with the dose reduction observed in this study points to the Nanopatch as a potential tool for facilitating inexpensive IPV for mass vaccination campaigns.

  20. Inactivated poliovirus type 2 vaccine delivered to rat skin via high density microprojection array elicits potent neutralising antibody responses

    Science.gov (United States)

    Muller, David A.; Pearson, Frances E.; Fernando, Germain J.P.; Agyei-Yeboah, Christiana; Owens, Nick S.; Corrie, Simon R.; Crichton, Michael L.; Wei, Jonathan C.J.; Weldon, William C.; Oberste, M. Steven; Young, Paul R.; Kendall, Mark A. F.

    2016-01-01

    Polio eradication is progressing rapidly, and the live attenuated Sabin strains in the oral poliovirus vaccine (OPV) are being removed sequentially, starting with type 2 in April 2016. For risk mitigation, countries are introducing inactivated poliovirus vaccine (IPV) into routine vaccination programs. After April 2016, monovalent type 2 OPV will be available for type 2 outbreak control. Because the current IPV is not suitable for house-to-house vaccination campaigns (the intramuscular injections require health professionals), we developed a high-density microprojection array, the Nanopatch, delivered monovalent type 2 IPV (IPV2) vaccine to the skin. To assess the immunogenicity of the Nanopatch, we performed a dose-matched study in rats, comparing the immunogenicity of IPV2 delivered by intramuscular injection or Nanopatch immunisation. A single dose of 0.2 D-antigen units of IPV2 elicited protective levels of poliovirus antibodies in 100% of animals. However, animals receiving IPV2 by IM required at least 3 immunisations to reach the same neutralising antibody titres. This level of dose reduction (1/40th of a full dose) is unprecedented for poliovirus vaccine delivery. The ease of administration coupled with the dose reduction observed in this study points to the Nanopatch as a potential tool for facilitating inexpensive IPV for mass vaccination campaigns. PMID:26911254

  1. Radiation Parameters of High Dose Rate Iridium -192 Sources

    Science.gov (United States)

    Podgorsak, Matthew B.

    A lack of physical data for high dose rate (HDR) Ir-192 sources has necessitated the use of basic radiation parameters measured with low dose rate (LDR) Ir-192 seeds and ribbons in HDR dosimetry calculations. A rigorous examination of the radiation parameters of several HDR Ir-192 sources has shown that this extension of physical data from LDR to HDR Ir-192 may be inaccurate. Uncertainty in any of the basic radiation parameters used in dosimetry calculations compromises the accuracy of the calculated dose distribution and the subsequent dose delivery. Dose errors of up to 0.3%, 6%, and 2% can result from the use of currently accepted values for the half-life, exposure rate constant, and dose buildup effect, respectively. Since an accuracy of 5% in the delivered dose is essential to prevent severe complications or tumor regrowth, the use of basic physical constants with uncertainties approaching 6% is unacceptable. A systematic evaluation of the pertinent radiation parameters contributes to a reduction in the overall uncertainty in HDR Ir-192 dose delivery. Moreover, the results of the studies described in this thesis contribute significantly to the establishment of standardized numerical values to be used in HDR Ir-192 dosimetry calculations.

  2. Bayer HealthCare Delivers a Dose of Reality for Cloud Payoff Mantras in Multinationals

    DEFF Research Database (Denmark)

    Winkler, Till J.; Benlian, Alexander; Piper, Marc

    2014-01-01

    Cloud services provide high cost advantages” is one of several often-quoted assertions (called mantras in this article) about payoffs from cloud computing. These mantras, however, have their origins in the experiences of small and mid-size companies, but, as the case of Bayer HealthCare’s cloud...

  3. Bayer HealthCare Delivers a Dose of Reality for Cloud Payoff Mantras in Multinationals

    DEFF Research Database (Denmark)

    Winkler, Till J.; Benlian, Alexander; Piper, Marc

    2014-01-01

    Cloud services provide high cost advantages” is one of several often-quoted assertions (called mantras in this article) about payoffs from cloud computing. These mantras, however, have their origins in the experiences of small and mid-size companies, but, as the case of Bayer HealthCare’s cloud-b......-based CRM rollout program shows, may not always be true for large multinational companies. To ensure payoffs from the cloud, multinationals must adopt strategies for coping with the inhibitors identified in this article.......Cloud services provide high cost advantages” is one of several often-quoted assertions (called mantras in this article) about payoffs from cloud computing. These mantras, however, have their origins in the experiences of small and mid-size companies, but, as the case of Bayer HealthCare’s cloud...

  4. Performance properties of the population bioequivalence approach for in vitro delivered dose for orally inhaled respiratory products.

    Science.gov (United States)

    Morgan, Beth; Strickland, Helen

    2014-01-01

    Regulatory agencies, industry, and academia have acknowledged that in vitro assessments serve a role in establishing bioequivalence for second-entry drug product approvals as well as innovator post-approval drug product changes. For orally inhaled respiratory products (OIPs), the issues of correctly analyzing in vitro data and interpreting the results within the broader context of therapeutic equivalence have garnered significant attention. One of the recommended statistical tests for in vitro data is the population bioequivalence method (PBE). The current literature for assessing the PBE statistical approach for in vitro data assumes a log normal distribution. This paper focuses on an assessment of that assumption for in vitro delivered dose. Concepts in development of a statistical model are presented. The PBE criterion and hypotheses are written for the case when data follows a normal distribution, rather than log normal. Results of a simulation study are reported, characterizing the performance of the PBE approach when data are expected to be normally distributed, rather than log normal. In these cases, decisions using the PBE approach are not consistent for the same absolute mean difference that the test product is from the reference product. A conclusion of inequivalency will occur more often if the test product dose is lower than the reference product for the same deviation from target. These features suggest that more research is needed for statistical equivalency approaches for in vitro data.

  5. Comparison of C-reactive protein levels with delivered dose of Kt/V in patients with end-stage renal disease on maintenance hemodialysis

    Directory of Open Access Journals (Sweden)

    Humayun Rashid

    2015-01-01

    Full Text Available The objective of our study is to compare the C-reactive protein (CRP levels with the delivered dose of dialysis in terms of Kt/V in patients undergoing maintenance hemodialysis (HD. This is a comparative, cross-sectional survey. The study was conducted at the HD unit of the Shaikh Zayed Hospital, Lahore, Pakistan. Patients who fulfilled the inclusion and exclusion criteria were enrolled in this study. The delivered dose of HD (Kt/V was assessed by an online clearance module (OCM in Fresenius machines at the end of every dialysis session and the weekly Kt/V was determined by adding all three Kt/V values. The serum CRP sample was taken after each session of HD and the mean CRP was calculated and considered elevated if it was >6 mg/dL. Both weekly Kt/V and CRP values were entered in a pre-designed proforma. Data were analyzed by using statistical software SPSS and P-value £0.05 was considered significant. Of 100 patients on maintenance HD, high serum CRP level (>6 mg/dL was found in 38 patients. When the Kt/V was compared with the CRP level, there was a negative correlation between the two parameters (r = 0.212, P = 0.032. Low Kt/V means dialysis inadequacy, which is associated with chronic inflammatory state, resulting in high CRP levels. We suggest that the quality of life of dialysis patients can be improved by offering an adequate dose of HD reflected by Kt/V ≥3.6/week.

  6. External radiotherapy or surveillance of stage 1 testes seminomas: comparison of irradiation doses delivered to the last testis; Radiotherapie externe ou surveillance des seminomes testiculaires de stade 1: comparaison des doses d'irradiation delivrees au testicule restant

    Energy Technology Data Exchange (ETDEWEB)

    Massabeau, C.; Filleron, T.; Delpuech, B.; Chevreau, C.; Mourey, L.; Bachaud, J.M. [Institut Claudius-Regaud, 31 - Toulouse (France); CHU Rangueil, 31 - Toulouse (France)

    2009-10-15

    Objective of the study: After orchidectomy, the standard treatment of seminoma s (stage 1) is adjuvant irradiation of ganglions currently supplanted by the strategy of simple surveillance because of recurrence rate under 20% and an excellent prognosis. Our prospective study had for objective to study by in vivo dosimetry the radiation doses delivered to the sane testis during an adjuvant irradiation of ganglion versus CT scan surveillance. The adjuvant irradiation of stage 1 seminomas delivers an insignificant dose to the sane testis in the guise of lead protection, almost twenty times inferior to that one delivered during a CT scan surveillance on ten years. These doses are negligible regarding the doses susceptible to affect the spermatogenesis and the fertility. (N.C.)

  7. Method and apparatus for delivering high power laser energy over long distances

    Energy Technology Data Exchange (ETDEWEB)

    Zediker, Mark S; Rinzler, Charles C; Faircloth, Brian O; Koblick, Yeshaya; Moxley, Joel F

    2015-04-07

    Systems, devices and methods for the transmission and delivery of high power laser energy deep into the earth and for the suppression of associated nonlinear phenomena. Systems, devices and methods for the laser drilling of a borehole in the earth. These systems can deliver high power laser energy down a deep borehole, while maintaining the high power to advance such boreholes deep into the earth and at highly efficient advancement rates.

  8. High-Dose Phenobarbital for Ohtahara Syndrome

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2002-05-01

    Full Text Available Oral high-dose phenobarbital therapy was effective in the control of tonic spasms in a 1 month-old-infant with early infantile epileptic encephalopathy with suppression bursts (Ohtahara syndrome treated at Tokyo Metropolitan Hachioji Children’s Hospital, Tokyo, Japan.

  9. [Hopes of high dose-rate radiotherapy].

    Science.gov (United States)

    Fouillade, Charles; Favaudon, Vincent; Vozenin, Marie-Catherine; Romeo, Paul-Henri; Bourhis, Jean; Verrelle, Pierre; Devauchelle, Patrick; Patriarca, Annalisa; Heinrich, Sophie; Mazal, Alejandro; Dutreix, Marie

    2017-04-01

    In this review, we present the synthesis of the newly acquired knowledge concerning high dose-rate irradiations and the hopes that these new radiotherapy modalities give rise to. The results were presented at a recent symposium on the subject. Copyright © 2017. Published by Elsevier Masson SAS.

  10. Method and apparatus for delivering high power laser energy over long distances

    Energy Technology Data Exchange (ETDEWEB)

    Zediker, Mark S; Rinzler, Charles C; Faircloth, Brian O; Koblick, Yeshaya; Moxley, Joel F

    2013-08-20

    Systems, devices and methods for the transmission of 1 kW or more of laser energy deep into the earth and for the suppression of associated nonlinear phenomena. Systems, devices and methods for the laser drilling of a borehole in the earth. These systems can deliver high power laser energy down a deep borehole, while maintaining the high power to advance such boreholes deep into the earth and at highly efficient advancement rates.

  11. Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer.

    Science.gov (United States)

    Martin, Jeffrey M; Handorf, Elizabeth A; Price, Robert A; Cherian, George; Buyyounouski, Mark K; Chen, David Y; Kutikov, Alexander; Johnson, Matthew E; Ma, Chung-Ming Charlie; Horwitz, Eric M

    2015-01-01

    A small decrease in testosterone level has been documented after prostate irradiation, possibly owing to the incidental dose to the testes. Testicular doses from prostate external beam radiation plans with either intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) were calculated to investigate any difference. Testicles were contoured for 16 patients being treated for localized prostate cancer. For each patient, 2 plans were created: 1 with IMRT and 1 with VMAT. No specific attempt was made to reduce testicular dose. Minimum, maximum, and mean doses to the testicles were recorded for each plan. Of the 16 patients, 4 received a total dose of 7800 cGy to the prostate alone, 7 received 8000 cGy to the prostate alone, and 5 received 8000 cGy to the prostate and pelvic lymph nodes. The mean (range) of testicular dose with an IMRT plan was 54.7 cGy (21.1 to 91.9) and 59.0 cGy (25.1 to 93.4) with a VMAT plan. In 12 cases, the mean VMAT dose was higher than the mean IMRT dose, with a mean difference of 4.3 cGy (p = 0.019). There was a small but statistically significant increase in mean testicular dose delivered by VMAT compared with IMRT. Despite this, it unlikely that there is a clinically meaningful difference in testicular doses from either modality.

  12. Comparison of testicular dose delivered by intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Jeffrey M. [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Handorf, Elizabeth A. [Department of Biostatistics, Fox Chase Cancer Center, Philadelphia, PA (United States); Price, Robert A.; Cherian, George [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Buyyounouski, Mark K. [Department of Radiation Oncology, Stanford University, Stanford, CA (United States); Chen, David Y.; Kutikov, Alexander [Department of Urologic Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Johnson, Matthew E.; Ma, Chung-Ming Charlie [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States); Horwitz, Eric M., E-mail: eric.horwitz@fccc.edu [Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA (United States)

    2015-10-01

    A small decrease in testosterone level has been documented after prostate irradiation, possibly owing to the incidental dose to the testes. Testicular doses from prostate external beam radiation plans with either intensity-modulated radiation therapy (IMRT) or volumetric-modulated arc therapy (VMAT) were calculated to investigate any difference. Testicles were contoured for 16 patients being treated for localized prostate cancer. For each patient, 2 plans were created: 1 with IMRT and 1 with VMAT. No specific attempt was made to reduce testicular dose. Minimum, maximum, and mean doses to the testicles were recorded for each plan. Of the 16 patients, 4 received a total dose of 7800 cGy to the prostate alone, 7 received 8000 cGy to the prostate alone, and 5 received 8000 cGy to the prostate and pelvic lymph nodes. The mean (range) of testicular dose with an IMRT plan was 54.7 cGy (21.1 to 91.9) and 59.0 cGy (25.1 to 93.4) with a VMAT plan. In 12 cases, the mean VMAT dose was higher than the mean IMRT dose, with a mean difference of 4.3 cGy (p = 0.019). There was a small but statistically significant increase in mean testicular dose delivered by VMAT compared with IMRT. Despite this, it unlikely that there is a clinically meaningful difference in testicular doses from either modality.

  13. Assessment of radiation doses to the para-aortic, pelvic, and inguinal lymph nodes delivered by image-guided adaptive brachytherapy in locally advanced cervical cancer

    DEFF Research Database (Denmark)

    Mohamed, Sandy M I; Aagaard, Torben; Fokdal, Lars U

    2015-01-01

    PURPOSE: This study evaluated the dose delivered to lymph nodes (LNs) by brachytherapy (BT) and the effect of BT image-guided optimization on the LN dose. METHODS AND MATERIALS: Twenty-five patients with locally advanced cervical cancer were retrospectively analyzed, 16 patients of them had LN...... involvement. The patients received whole pelvis intensity-modulated radiation therapy (45-50 Gy/25-30 fx) to whole pelvis and two fractions of MRI pulsed-dose-rate BT. The delineated LN groups were para-aortic, inguinal, common iliac (CI), external iliac, internal iliac, obturator, and presacral. For each LN...... group, D98%, D50%, and D2% (the dose that covers 98%, 50%, and 2% of the volume, respectively) were evaluated for optimized and standard BT plans. The correlation between total reference air kerma (TRAK) and D50% of the LN groups was evaluated. RESULTS: BT contributed considerable dose (mean D50% was 3...

  14. Impact of different beam directions on intensity-modulated radiation therapy dose delivered to functioning lung tissue identified using single-photon emission computed tomography.

    Science.gov (United States)

    Tian, Qin; Zhang, Fucheng; Wang, Yanming; Qu, Weiqiang

    2014-01-01

    To use different beam arrangements and numbers to plan intensity-modulated radiation therapy (IMRT) and investigate their effects on low and high radiation doses delivered to the functional lung, in order to reduce radiation-induced lung damage. Ten patients with stage I-III non-small cell lung carcinoma (NSCLC) underwent IMRT. Beam arrangements were selected on the basis of orientation and dose-volume histograms to create SPECT-guided IMRT plans that spared the functional lung and maintained target coverage. Four different plans, including CT-7, SPECT-7, SPECT-4, SPECT-5 with different beam arrangements, were used. The differences of conformity index (CI), heterogeneity index (HI) between the plans were analyzed, by using a paired t-test. The seven-beam SPECT (SPECT-7) plan reduced the volume of the functional lung irradiated with at least 20 Gy (FV20) and 30 Gy (FV30) by 26.02% ±15.45% and 14.41% ±16.66%, respectively, as compared to the seven-beam computed tomography (CT-7) plan. The CI significantly differed between the SPECT-7 and SPECT-4 plans and between the SPECT-5 and SPECT-4 plans, but not between the SPECT-5 and SPECT-7 plans. The CIs in the SPECT-5 and SPECT-7 plans were better than that in the SPECT-4 plan. The heterogeneity index significantly differed among the three SPECT plans and was best in the SPECT-7 plan. The incorporation of SPECT images into IMRT planning for NSCLC greatly affected beam angles and number of beams. Fewer beams and modified beam angles achieved similar or better IMRT quality. The low-dose volumes were lower in SPECT-4.

  15. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, Antonio Cassio Assis, E-mail: acapellizzon@hcancer.org.br [A.C. Camargo Cancer Center, Sao Paulo, SP (Brazil). Departamento de Radioterapia

    2016-05-15

    For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy. (author)

  16. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer*

    Science.gov (United States)

    Pellizzon, Antônio Cássio Assis

    2016-01-01

    For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy. PMID:27403021

  17. SU-E-T-205: Improving Quality Assurance of HDR Brachytherapy: Verifying Agreement Between Planned and Delivered Dose Distributions Using DICOM RTDose and Advanced Film Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, A L [Portsmouth Hospitals NHS Trust, Portsmouth, Hampshire (United Kingdom); University of Surrey, Guildford, Surrey (United Kingdom); Bradley, D A [University of Surrey, Guildford, Surrey (United Kingdom); Nisbet, A [University of Surrey, Guildford, Surrey (United Kingdom); Royal Surrey County Hospital NHS Foundation Trust, Guildford, Surrey (United Kingdom)

    2014-06-01

    Purpose: HDR brachytherapy is undergoing significant development, and quality assurance (QA) checks must keep pace. Current recommendations do not adequately verify delivered against planned dose distributions: This is particularly relevant for new treatment planning system (TPS) calculation algorithms (non TG-43 based), and an era of significant patient-specific plan optimisation. Full system checks are desirable in modern QA recommendations, complementary to device-centric individual tests. We present a QA system incorporating TPS calculation, dose distribution export, HDR unit performance, and dose distribution measurement. Such an approach, more common in external beam radiotherapy, has not previously been reported in the literature for brachytherapy. Methods: Our QA method was tested at 24 UK brachytherapy centres. As a novel approach, we used the TPS DICOM RTDose file export to compare planned dose distribution with that measured using Gafchromic EBT3 films placed around clinical brachytherapy treatment applicators. Gamma analysis was used to compare the dose distributions. Dose difference and distance to agreement were determined at prescription Point A. Accurate film dosimetry was achieved using a glass compression plate at scanning to ensure physically-flat films, simultaneous scanning of known dose films with measurement films, and triple-channel dosimetric analysis. Results: The mean gamma pass rate of RTDose compared to film-measured dose distributions was 98.1% at 3%(local), 2 mm criteria. The mean dose difference, measured to planned, at Point A was -0.5% for plastic treatment applicators and -2.4% for metal applicators, due to shielding not accounted for in TPS. The mean distance to agreement was 0.6 mm. Conclusion: It is recommended to develop brachytherapy QA to include full-system verification of agreement between planned and delivered dose distributions. This is a novel approach for HDR brachytherapy QA. A methodology using advanced film

  18. SU-C-202-03: A Tool for Automatic Calculation of Delivered Dose Variation for Off-Line Adaptive Therapy Using Cone Beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, B; Lee, S; Chen, S; Zhou, J; Prado, K; D’Souza, W; Yi, B [University of Maryland School of Medicine, Baltimore, MD (United States)

    2016-06-15

    Purpose: Monitoring the delivered dose is an important task for the adaptive radiotherapy (ART) and for determining time to re-plan. A software tool which enables automatic delivered dose calculation using cone-beam CT (CBCT) has been developed and tested. Methods: The tool consists of four components: a CBCT Colleting Module (CCM), a Plan Registration Moduel (PRM), a Dose Calculation Module (DCM), and an Evaluation and Action Module (EAM). The CCM is triggered periodically (e.g. every 1:00 AM) to search for newly acquired CBCTs of patients of interest and then export the DICOM files of the images and related registrations defined in ARIA followed by triggering the PRM. The PRM imports the DICOM images and registrations, links the CBCTs to the related treatment plan of the patient in the planning system (RayStation V4.5, RaySearch, Stockholm, Sweden). A pre-determined CT-to-density table is automatically generated for dose calculation. Current version of the DCM uses a rigid registration which regards the treatment isocenter of the CBCT to be the isocenter of the treatment plan. Then it starts the dose calculation automatically. The AEM evaluates the plan using pre-determined plan evaluation parameters: PTV dose-volume metrics and critical organ doses. The tool has been tested for 10 patients. Results: Automatic plans are generated and saved in the order of the treatment dates of the Adaptive Planning module of the RayStation planning system, without any manual intervention. Once the CTV dose deviates more than 3%, both email and page alerts are sent to the physician and the physicist of the patient so that one can look the case closely. Conclusion: The tool is capable to perform automatic dose tracking and to alert clinicians when an action is needed. It is clinically useful for off-line adaptive therapy to catch any gross error. Practical way of determining alarming level for OAR is under development.

  19. High-dose neutron detector project update

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, Howard Olsen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Henzlova, Daniela [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-10

    These are the slides for a progress review meeting by the sponsor. This is an update on the high-dose neutron detector project. In summary, improvements in both boron coating and signal amplification have been achieved; improved boron coating materials and procedures have increase efficiency by ~ 30-40% without the corresponding increase in the detector plate area; low dead-time via thin cell design (~ 4 mm gas gaps) and fast amplifiers; prototype PDT 8” pod has been received and testing is in progress; significant improvements in efficiency and stability have been verified; use commercial PDT 10B design and fabrication to obtain a faster path from the research to practical high-dose neutron detector.

  20. High-dose erythropoietin for tissue protection

    DEFF Research Database (Denmark)

    Lund, Anton; Lundby, Carsten; Olsen, Niels Vidiendal

    2014-01-01

    BACKGROUND: The discovery of potential anti-apoptotic and cytoprotective effects of recombinant human erythropoietin (rHuEPO) has led to clinical trials investigating the use of high-dose, short-term rHuEPO therapy for tissue protection in conditions such as stroke and myocardial infarction....... Experimental studies have been favourable, but the clinical efficacy has yet to be validated. MATERIALS AND METHODS: We have reviewed clinical studies regarding the use of high-dose, short-term rHuEPO therapy for tissue protection in humans with the purpose to detail the safety and efficacy of r...... no effect of rHuEPO therapy on measures of tissue protection. Five trials including 1025 patients reported safety concerns in the form of increased mortality or adverse event rates. No studies reported reduced mortality. CONCLUSIONS: Evidence is sparse to support a tissue-protective benefit of r...

  1. High-dose neutron detector project update

    Energy Technology Data Exchange (ETDEWEB)

    Menlove, Howard Olsen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Henzlova, Daniela [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-10

    These are the slides for a progress review meeting by the sponsor. This is an update on the high-dose neutron detector project. In summary, improvements in both boron coating and signal amplification have been achieved; improved boron coating materials and procedures have increased efficiency by ~ 30-40% without the corresponding increase in the detector plate area; low dead-time via thin cell design (~ 4 mm gas gaps) and fast amplifiers; prototype PDT 8” pod has been received and testing is in progress; significant improvements in efficiency and stability have been verified; use commercial PDT 10B design and fabrication to obtain a faster path from the research to practical high-dose neutron detector.

  2. Adaptive planning strategy for high dose rate prostate brachytherapy—a simulation study on needle positioning errors

    NARCIS (Netherlands)

    Borot, Maxence; Denis de Senneville, B; Maenhout, M; Hautvast, G; Binnekamp, D; Lagendijk, J J W; van Vulpen, M; Moerland, M A

    2016-01-01

    The development of magnetic resonance (MR) guided high dose rate (HDR) brachytherapy for prostate cancer has gained increasing interest for delivering a high tumor dose safely in a single fraction. To support needle placement in the limited workspace inside the closed-bore MRI, a single-needle MR-co

  3. Amphotericin B for cryptococcal meningitis in HIV positive patients: Low dose versus high dose

    Directory of Open Access Journals (Sweden)

    Rajeshwari S

    2007-01-01

    Full Text Available Aim: To compare the safety and efficacy of low dose vs high dose of amphotericin B in cryptococcal meningitis associated with HIV infection. Materials and Methods: Retrospective data of patients admitted with clinical diagnosis with or without microbiological evidence of cryptococcal meningitis was collected from Jan 2000-Mar 2006. Patients′ details were collected in a proforma which included patient′s age, weight, signs and symptoms of disease and microbiological report (blood and CSF analysis. Data also included coexisting disease; concomitant medications taken along with amphotericin B. Adverse drug reactions which occurred during the period of treatment were recorded. Patients were grouped as low dose group and high dose group depending on the dose of amphotericin B given for the treatment of cryptococcal meningitis. Patients who received amphotericin B at doses of 0.33 to 0.64 mg/kg body weight per day were categorized under low dose group and patients who received amphotericin B at doses of 0.7 to 1.1 mg/kg/day were categorized under high dose group. All data were pooled and analyzed between the groups using chi square test. Result: Total number of patients included in the study were 38, 26 in the low dose group and 12 in the high dose group. In the low dose group, 20 were males and six were females, in the high dose group eight were males and four were females. The commonest underlying diseases were tuberculosis (17 in low dose group, nine in high dose group, Pneumocystis carinii (jeroveci pneumonia (16 in low dose group, seven in high dose group and oral candidiasis (eight in low dose group, seven in high dose group, Toxoplasmosis (three in low dose group, one in high dose group, hypertension (1 in group A and diabetes mellitus (1 in group B. Concomitant medication received along with amphotericin B for coexisting diseases in both the groups were antitubercular therapy, cotrimoxazole, antiviral therapy and premedications such as

  4. Donut-shaped high-dose configuration for proton beam radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Rutz, H.P.; Lomax, A.J. [Div. of Radiation Medicine, Paul Scherrer Inst., Villigen PSI (Switzerland)

    2005-01-01

    Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning technology allow a potentially clinically useful approach which is also applicable to spare other critical structures passing through a target volume, including spinal cord, optic nerves, chiasm, brain stem, or urethra. (orig.)

  5. High dose insulin in toxic cardiogenic shock.

    Science.gov (United States)

    Holger, Joel S; Engebretsen, Kristin M; Marini, John J

    2009-04-01

    To report the successful use of high dose insulin (HDI) in previously unreported insulin dosing ranges in a patient with severe myocardial toxicity due to an amitriptyline and citalopram overdose. A 65-year-old female presented in respiratory arrest, which was followed by bradycardic pulseless electrical activity after ingesting multiple medications. After a prolonged resuscitation, the patient was maintained only on infusions of norepinephrine (40 mcg/min), vasopressin (4 units/h), insulin (80 units/h), and sodium bicarbonate. Due to a deteriorating clinical condition and limited prognosis, the insulin infusion was titrated incrementally upwards to 600 units/h (6 units/kg/h) over a 5 h time period while simultaneously completely weaning off both vasopressors. She developed brisk pulses and warm extremities, and her cardiac output nearly tripled. After 2 days of stabilization the insulin was slowly tapered, and the patient recovered. HDI as a single cardiovascular agent significantly improved clinical and cardiovascular parameters after the failure of vasopressor therapy in severe cardiovascular toxicity. Higher doses of insulin than previously recommended may be needed in toxic poisonings when severe myocardial depression is present.

  6. Monitor units are not predictive of neutron dose for high-energy IMRT

    Directory of Open Access Journals (Sweden)

    Hälg Roger A

    2012-08-01

    Full Text Available Abstract Background Due to the substantial increase in beam-on time of high energy intensity-modulated radiotherapy (>10 MV techniques to deliver the same target dose compared to conventional treatment techniques, an increased dose of scatter radiation, including neutrons, is delivered to the patient. As a consequence, an increase in second malignancies may be expected in the future with the application of intensity-modulated radiotherapy. It is commonly assumed that the neutron dose equivalent scales with the number of monitor units. Methods Measurements of neutron dose equivalent were performed for an open and an intensity-modulated field at four positions: inside and outside of the treatment field at 0.2 cm and 15 cm depth, respectively. Results It was shown that the neutron dose equivalent, which a patient receives during an intensity-modulated radiotherapy treatment, does not scale with the ratio of applied monitor units relative to an open field irradiation. Outside the treatment volume at larger depth 35% less neutron dose equivalent is delivered than expected. Conclusions The predicted increase of second cancer induction rates from intensity-modulated treatment techniques can be overestimated when the neutron dose is simply scaled with monitor units.

  7. TH-A-19A-03: Impact of Proton Dose Calculation Method On Delivered Dose to Lung Tumors: Experiments in Thorax Phantom and Planning Study in Patient Cohort

    Energy Technology Data Exchange (ETDEWEB)

    Grassberger, C; Daartz, J; Dowdell, S; Ruggieri, T; Sharp, G; Paganetti, H [Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)

    2014-06-15

    Purpose: Evaluate Monte Carlo (MC) dose calculation and the prediction of the treatment planning system (TPS) in a lung phantom and compare them in a cohort of 20 lung patients treated with protons. Methods: A 2-dimensional array of ionization chambers was used to evaluate the dose across the target in a lung phantom. 20 lung cancer patients on clinical trials were re-simulated using a validated Monte Carlo toolkit (TOPAS) and compared to the TPS. Results: MC increases dose calculation accuracy in lung compared to the clinical TPS significantly and predicts the dose to the target in the phantom within ±2%: the average difference between measured and predicted dose in a plane through the center of the target is 5.6% for the TPS and 1.6% for MC. MC recalculations in patients show a mean dose to the clinical target volume on average 3.4% lower than the TPS, exceeding 5% for small fields. The lower dose correlates significantly with aperture size and the distance of the tumor to the chest wall (Spearman's p=0.0002/0.004). For large tumors MC also predicts consistently higher V{sub 5} and V{sub 10} to the normal lung, due to a wider lateral penumbra, which was also observed experimentally. Critical structures located distal to the target can show large deviations, though this effect is very patient-specific. Conclusion: Advanced dose calculation techniques, such as MC, would improve treatment quality in proton therapy for lung cancer by avoiding systematic overestimation of target dose and underestimation of dose to normal lung. This would increase the accuracy of the relationships between dose and effect, concerning tumor control as well as normal tissue toxicity. As the role of proton therapy in the treatment of lung cancer continues to be evaluated in clinical trials, this is of ever-increasing importance. This work was supported by National Cancer Institute Grant R01CA111590.

  8. High brachytherapy doses can counteract hypoxia in cervical cancer—a modelling study

    Science.gov (United States)

    Lindblom, Emely; Dasu, Alexandru; Beskow, Catharina; Toma-Dasu, Iuliana

    2017-01-01

    Tumour hypoxia is a well-known adverse factor for the outcome of radiotherapy. For cervical tumours in particular, several studies indicate large variability in tumour oxygenation. However, clinical evidence shows that the management of cervical cancer including brachytherapy leads to high rate of success. It was the purpose of this study to investigate whether the success of brachytherapy for cervical cancer, seemingly regardless of oxygenation status, could be explained by the characteristics of the brachytherapy dose distributions. To this end, a previously used in silico model of tumour oxygenation and radiation response was further developed to simulate the treatment of cervical cancer employing a combination of external beam radiotherapy and intracavitary brachytherapy. Using a clinically-derived brachytherapy dose distribution and assuming a homogeneous dose delivered by external radiotherapy, cell survival was assessed on voxel level by taking into account the variation of sensitivity with oxygenation as well as the effects of repair, repopulation and reoxygenation during treatment. Various scenarios were considered for the conformity of the brachytherapy dose distribution to the hypoxic region in the target. By using the clinically-prescribed brachytherapy dose distribution and varying the total dose delivered with external beam radiotherapy in 25 fractions, the resulting values of the dose for 50% tumour control, D 50, were in agreement with clinically-observed values for high cure rates if fast reoxygenation was assumed. The D 50 was furthermore similar for the different degrees of conformity of the brachytherapy dose distribution to the tumour, regardless of whether the hypoxic fraction was 10%, 25%, or 40%. To achieve 50% control with external RT only, a total dose of more than 70 Gy in 25 fractions would be required for all cases considered. It can thus be concluded that the high doses delivered in brachytherapy can counteract the increased

  9. A Monte Carlo study on the effect of the orbital bone to the radiation dose delivered to the eye lens

    Science.gov (United States)

    Stratis, Andreas; Zhang, Guozhi; Jacobs, Reinhilde; Bogaerts, Ria; Bosmans, Hilde

    2015-03-01

    The aim of this work was to investigate the influence of backscatter radiation from the orbital bone and the intraorbital fat on the eye lens dose in the dental CBCT energy range. To this end we conducted three different yet interrelated studies; A preliminary simulation study was conducted to examine the impact of a bony layer situated underneath a soft tissue layer on the amount of backscatter radiation. We compared the Percentage Depth Dose (PDD) curves in soft tissue with and without the bone layer and we estimated the depth in tissue where the decrease in backscatter caused by the presence of the bone is noticeable. In a supplementary study, an eye voxel phantom was designed with the DOSxyznrc code. Simulations were performed exposing the phantom at different x-ray energies sequentially in air, in fat tissue and in realistic anatomy with the incident beam perpendicular to the phantom. Finally, a virtual head phantom was implemented into a validated hybrid Monte Carlo (MC) framework to simulate a large Field of View protocol of a real CBCT scanner and examine the influence of scattered dose to the eye lens during the whole rotation of the paired tube-detector system. The results indicated an increase in the dose to the lens due to the fatty tissue in the surrounding anatomy. There is a noticeable dose reduction close to the bone-tissue interface which weakens with increasing distance from the interface, such that the impact of the orbital bone in the eye lens dose becomes small.

  10. SU-E-T-515: Field-In-Field Compensation Technique Using Multi-Leaf Collimator to Deliver Total Body Irradiation (TBI) Dose

    Energy Technology Data Exchange (ETDEWEB)

    Lakeman, T [The State University of New York at Buffalo (United States); Wang, IZ [The State University of New York at Buffalo (United States); Roswell Park Cancer Institute, Buffalo, NY (United States)

    2014-06-01

    Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient's immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has been used conventionally to compensate for the varying thickness through the entire body in large-field TBI. The goal of this study is to pursue utilizing the modern field-in-field (FIF) technique with the multi-leaf collimator (MLC) to more accurately and efficiently deliver dose to patients in need of TBI. Method: Treatment plans utilizing the FIF technique to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Treatment fields include one pair of opposed open large fields (collimator=45°) with a specific weighting and a succession of smaller fields (collimator=90°) each with their own weighting. The smaller fields are shaped by moving MLC to block the sections of the patient which have already received close to 100% of the prescribed dose. The weighting factors for each of these fields were calculated using the attenuation coefficient of the initial lead compensators and the separation of the patient in different positions in the axial plane. Results: Dose-volume histograms (DVH) were calculated for evaluating the FIF compensation technique. The maximum body doses calculated from the DVH were reduced from the non-compensated 179.3% to 148.2% in the FIF plans, indicating a more uniform dose with the FIF compensation. All calculated monitor units were well within clinically acceptable limits and exceeded those of the original lead compensation plan by less than 50 MU (only ~1.1% increase). Conclusion: MLC FIF technique for TBI will not significantly increase the beam on time while it can substantially reduce the compensator setup time and the potential risk of errors in manually placing lead compensators.

  11. Joining Forces: Collaborating Internationally to Deliver High-Quality, Online Postgraduate Education in Pain Management

    Directory of Open Access Journals (Sweden)

    Elizabeth Devonshire

    2011-01-01

    Full Text Available The effective management of pain is a complex and costly global issue, requiring a range of innovative educational strategies to enable culturally appropriate and high-quality health care provision. In response to this issue, the Pain Management Research Institute at the University of Sydney (Sydney, Australia has established several strategic alliances with other overseas universities to deliver online postgraduate education in pain management. The present article discusses the rationale for joining forces, and the approach adopted in creating and maintaining these alliances. It also provides insights into the benefits, challenges and opportunities associated with collaborative educational initiatives of this nature, from institutional, academic and student perspectives.

  12. SU-E-J-154: Deformable Image Registration Based Delivered Dose Estimation for Head and Neck Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kumarasiri, A; Liu, C; Chetvertkov, M; Gordon, J; Siddiqui, F; Chetty, I; Kim, J [Henry Ford Health System, Detroit, MI (United States)

    2014-06-01

    Purpose: To estimate the accumulated dose to targets and organs at risk (OAR) for head and neck (H'N) radiotherapy using 3 deformable image registration (DIR) algorithms. Methods: Five H'N patients, who had daily CBCTs taken during the course of treatment, were retrospectively studied. All plans had 5 mm CTV-to-PTV expansions. To overcome the small field of view (FOV) limitations and HU uncertainties of CBCTs, CT images were deformably registered using a parameter-optimized B-spline DIR algorithm (Elastix, elastix.isi.uu.nl) and resampled onto each CBCT with a 4 cm uniform FOV expansion. The dose of the day was calculated on these resampled CT images. Calculated daily dose matrices were warped and accumulated to the planning CT using 3 DIR algorithms; SmartAdapt (Eclipse/Varian), Velocity (Velocity Medical Solutions), and Elastix. Dosimetric indices for targets and OARs were determined from the DVHs and compared with corresponding planned quantities. Results: The cumulative dose deviation was less than 2%, on average, for PTVs from the corresponding plan dose, for all algorithms/patients. However, the parotids show as much as a 37% deviation from the intended dose, possibly due to significant patient weight loss during the first 3 weeks of treatment (15.3 lbs in this case). The mean(±SD) cumulative dose deviations of the 5 patients estimated using the 3 algorithms (SmartAdapt, Velocity, and Elastix) were (0.8±0.9%, 0.5±0.9%, 0.6±1.3%) for PTVs, (1.6±1.9%, 1.4±2.0%, 1.7±1.9%) for GTVs, (10.4±12.1%, 10.7±10.6%, 6.5±10.1%) for parotid glands, and (4.5±4.6%, 3.4±5.7%, 3.9±5.7%) for mucosa, respectively. The differences among the three DIR algorithms in the estimated cumulative mean doses (1SD (in Gy)) were: 0.1 for PTVs, 0.1 for GTVs, 1.9 for parotid glands, and 0.4 for mucosa. Conclusion: Results of this study are suggestive that more frequent plan adaptation for organs, such as the parotid glands, might be beneficial during the course of H

  13. WE-EF-BRA-03: Catheter- Free Ablation with External Photon Radiation: Treatment Planning, Delivery Considerations, and Correlation of Effects with Delivered Dose

    Energy Technology Data Exchange (ETDEWEB)

    Deisher, A; Anderson, S; Cusma, J; Herman, M; Johnson, S; Lehmann, H; Packer, D; Parker, K; Song, L; Takami, M; Kruse, J [Mayo Clinic, Rochester, MN (United States)

    2015-06-15

    Purpose: To plan, target, and calculate delivered dose in atrioventricular node (AVN) ablation with volume-modulated arc therapy (VMAT) in an intact porcine model. Methods: Seven pigs underwent AVN irradiation, with prescription doses ranging between 25 and 55Gy in a single fraction. Cardiac CT scans were acquired at expiration. Two physicians contoured AVN targets on 10 phases, providing estimates of target motion and inter-physician variability. Treatment planning was conducted on a static phase-averaged CT. The volume designated to receive prescription dose covered the full extent of AVN cardiac motion, expanded by 4mm for setup uncertainty. Optimization limited doses to risk structures according to single-fraction tumor treatment protocols. Orthogonal kV images were used to align bony anatomy at time of treatment. Localization was further refined with respiratory-gated cone-beam CT, and range of cardiac motion was verified under fluoroscopy. Beam delivery was respiratory-gated for expiration with a mean efficiency of 60%. Deformable registration of the 10 cardiac CT phases was used to calculate actual delivered dose for comparison to electro-anatomical and visually evident lesions. Results: The mean [minimum,maximum] amplitude of AVN cardiac motion was LR 2.9 [1.7,3.9]mm, AP 6.6 [4.4,10.4]mm, and SI 5.6 [2.0,9.9]mm. Incorporating cardiac motion into the dose calculation showed the volume receiving full dose was 40–80% of the volume indicated on the static planning image, although the contoured AVN target received full dose in all animals. Initial results suggest the dimensions of the electro-anatomical lesion are correlated with the 40Gy isodose volume. Conclusion: Image-guidance techniques allow for accurate and precise delivery of VMAT for catheter-free arrhythmia ablation. An arsenal of advanced radiation planning, dose optimization, and image-guided delivery techniques was employed to assess and mitigate effects of cardiac and respiratory motion

  14. Application of RADPOS in Vivo Dosimetry for QA of High Dose Rate Brachytherapy

    DEFF Research Database (Denmark)

    Cherpak, A.; Kertzscher Schwencke, Gustavo Adolfo Vladimir; Cygler, J.

    2012-01-01

    Gy. Conclusions: In vivo dosimetry can potentially signal errors in catheter placement or numbering before entire dose is delivered. The demonstrated accuracy of RADPOS dose measurements and its ability to simultaneously measure displacement makes it a powerful tool for HDR brachytherapy treatments for prostate...... cancer, where high dose gradients and movement of the prostate gland can present unique in vivo dosimetry challenges. Financial and technical support has been received from Best Medical Canada and Ascension Technology Corporation. © 2012 American Association of Physicists in Medicine...

  15. The application of high dose food irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Bruyn, I. De [Atomic Energy Corporation of South Africa LTD, Building 2000, P.O. Box 582, Pretoria 0001, (South Africa)

    1997-12-31

    During the 1950`s to end 1970`s the United States Army developed the basic methodology to produce shelf stable irradiated meat, seafood and poultry products. These products are normally packed without gravy, sauce or brine, as liquid is not required to sterilize the product as in the canning process. This leads to the distinctive `dried cooked` taste normally associated with roasts opposed to the casserole taste usually associated with tinned meats. The meats are cooked, chilled, portioned, vacuum packed and irradiated to the required minimum dose of 25 to 45 kGy (depending on the product) at a temperature of between -20 and -40 Centigrade to ensure absolute sterility even under tropical conditions. The product is packaged in a high quality four layer laminate pouch and will therefore not rust or burst even under adverse weather conditions. The product can be guaranteed for more than two years as long as the integrity of the packaging is maintained. (Author)

  16. Low-dose oxytocin delivered intranasally with Breath Powered device affects social-cognitive behavior: a randomized four-way crossover trial with nasal cavity dimension assessment.

    Science.gov (United States)

    Quintana, D S; Westlye, L T; Rustan, Ø G; Tesli, N; Poppy, C L; Smevik, H; Tesli, M; Røine, M; Mahmoud, R A; Smerud, K T; Djupesland, P G; Andreassen, O A

    2015-07-14

    Despite the promise of intranasal oxytocin (OT) for modulating social behavior, recent work has provided mixed results. This may relate to suboptimal drug deposition achieved with conventional nasal sprays, inter-individual differences in nasal physiology and a poor understanding of how intranasal OT is delivered to the brain in humans. Delivering OT using a novel 'Breath Powered' nasal device previously shown to enhance deposition in intranasal sites targeted for nose-to-brain transport, we evaluated dose-dependent effects on social cognition, compared response with intravenous (IV) administration of OT, and assessed nasal cavity dimensions using acoustic rhinometry. We adopted a randomized, double-blind, double-dummy, crossover design, with 16 healthy male adults completing four single-dose treatments (intranasal 8 IU (international units) or 24 IU OT, 1 IU OT IV and placebo). The primary outcome was social cognition measured by emotional ratings of facial images. Secondary outcomes included the pharmacokinetics of OT, vasopressin and cortisol in blood and the association between nasal cavity dimensions and emotional ratings. Despite the fact that all the treatments produced similar plasma OT increases compared with placebo, there was a main effect of treatment on anger ratings of emotionally ambiguous faces. Pairwise comparisons revealed decreased ratings after 8 IU OT in comparison to both placebo and 24 IU OT. In addition, there was an inverse relationship between nasal valve dimensions and anger ratings of ambiguous faces after 8-IU OT treatment. These findings provide support for a direct nose-to-brain effect, independent of blood absorption, of low-dose OT delivered from a Breath Powered device.

  17. Delivering high quality hip fracture rehabilitation: the perspective of occupational and physical therapy practitioners.

    Science.gov (United States)

    Leland, Natalie E; Lepore, Michael; Wong, Carin; Chang, Sun Hwa; Freeman, Lynn; Crum, Karen; Gillies, Heather; Nash, Paul

    2017-01-23

    The majority of post-acute hip fracture rehabilitation in the US is delivered in skilled nursing facilities (SNFs). Currently, there are limited guidelines that equip occupational and physical therapy practitioners with a summary of what constitutes evidence-based high quality rehabilitation. Thus, this study aimed to identify rehabilitation practitioners' perspectives on the practices that constitute high quality hip fracture rehabilitation. Focus groups were conducted with 99 occupational and physical therapy practitioners working in SNFs in southern California. Purposive sampling of facilities was conducted to capture variation in key characteristics known to impact care delivery for this patient population (e.g., financial resources, staffing, and patient case-mix). Questions aimed to elicit practitioners' perspectives on high quality hip fracture rehabilitation practices. Each session was audio-recorded and transcribed. Data were systematically analyzed using a modified grounded theory approach. Seven themes emerged: objectives of care; first 72 h; positioning, pain, and precautions; use of standardized assessments; episode of care practices; facilitating insight into progress; and interdisciplinary collaboration. Clinical guidelines are critical tools to facilitate clinical decision-making and achieve desired patient outcomes. The findings of this study highlight the practitioners' perspective on what constitutes high quality hip fracture rehabilitation. This work provides critical information to advance the development of stakeholder-driven rehabilitation clinical guidelines. Future research is needed to verify the findings from other stakeholders (e.g., patients), ensure the alignment of our findings with current evidence, and develop measures for evaluating their delivery and relationship to desired outcomes. Implications for Rehabilitation This study highlights occupational and physiotherapy therapy practitioners' perspectives on the cumulative best

  18. Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities.

    Science.gov (United States)

    Lechuga, Lawrence; Weidlich, Georg A

    2016-09-12

    A comparison of image quality and dose delivered between two differing computed tomography (CT) imaging modalities-fan beam and cone beam-was performed. A literature review of quantitative analyses for various image quality aspects such as uniformity, signal-to-noise ratio, artifact presence, spatial resolution, modulation transfer function (MTF), and low contrast resolution was generated. With these aspects quantified, cone beam computed tomography (CBCT) shows a superior spatial resolution to that of fan beam, while fan beam shows a greater ability to produce clear and anatomically correct images with better soft tissue differentiation. The results indicate that fan beam CT produces superior images to that of on-board imaging (OBI) cone beam CT systems, while providing a considerably less dose to the patient.

  19. Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities

    Science.gov (United States)

    Weidlich, Georg A.

    2016-01-01

    A comparison of image quality and dose delivered between two differing computed tomography (CT) imaging modalities—fan beam and cone beam—was performed. A literature review of quantitative analyses for various image quality aspects such as uniformity, signal-to-noise ratio, artifact presence, spatial resolution, modulation transfer function (MTF), and low contrast resolution was generated. With these aspects quantified, cone beam computed tomography (CBCT) shows a superior spatial resolution to that of fan beam, while fan beam shows a greater ability to produce clear and anatomically correct images with better soft tissue differentiation. The results indicate that fan beam CT produces superior images to that of on-board imaging (OBI) cone beam CT systems, while providing a considerably less dose to the patient. PMID:27752404

  20. Using Behavioral Economics to Design Physician Incentives That Deliver High-Value Care.

    Science.gov (United States)

    Emanuel, Ezekiel J; Ubel, Peter A; Kessler, Judd B; Meyer, Gregg; Muller, Ralph W; Navathe, Amol S; Patel, Pankaj; Pearl, Robert; Rosenthal, Meredith B; Sacks, Lee; Sen, Aditi P; Sherman, Paul; Volpp, Kevin G

    2016-01-19

    Behavioral economics provides insights about the development of effective incentives for physicians to deliver high-value care. It suggests that the structure and delivery of incentives can shape behavior, as can thoughtful design of the decision-making environment. This article discusses several principles of behavioral economics, including inertia, loss aversion, choice overload, and relative social ranking. Whereas these principles have been applied to motivate personal health decisions, retirement planning, and savings behavior, they have been largely ignored in the design of physician incentive programs. Applying these principles to physician incentives can improve their effectiveness through better alignment with performance goals. Anecdotal examples of successful incentive programs that apply behavioral economics principles are provided, even as the authors recognize that its application to the design of physician incentives is largely untested, and many outstanding questions exist. Application and rigorous evaluation of infrastructure changes and incentives are needed to design payment systems that incentivize high-quality, cost-conscious care.

  1. Motion-Compensated Estimation of Delivered Dose during External BeamRadiation Therapy: Implementation in Philips’ Pinnacle3 Treatment Planning System

    NARCIS (Netherlands)

    Bharat, S.; Parikh, P.; Noel, C.; Meltsner, M.; Bzdusek, K.; Kaus, M.

    2012-01-01

    Purpose: Recent research efforts investigating dose escalation techniques for three-dimensional conformal radiation therapy (3D CRT) andintensity modulated radiation therapy (IMRT) have demonstrated great benefit when high-dose hypofractionated treatment schemes are implemented16,21. The use of the

  2. Two doses of bovine viral diarrhea virus DNA vaccine delivered by electroporation induce long-term protective immune responses.

    Science.gov (United States)

    van Drunen Littel-van den Hurk, Sylvia; Lawman, Zoe; Snider, Marlene; Wilson, Don; van den Hurk, Jan V; Ellefsen, Barry; Hannaman, Drew

    2013-02-01

    Bovine viral diarrhea virus (BVDV) is a pathogen of major importance in cattle, so there is a need for new effective vaccines. DNA vaccines induce balanced immune responses and are relatively inexpensive and thus promising for both human and veterinary applications. In this study, newborn calves with maternal antibodies were vaccinated intramuscularly (i.m.) with a BVDV E2 DNA vaccine with the TriGrid Delivery System for i.m. delivery (TDS-IM). Two doses of this vaccine spaced 6 or 12 weeks apart were sufficient to induce significant virus-neutralizing antibody titers, numbers of activated T cells, and reduction in viral shedding and clinical presentations after BVDV-2 challenge. In contrast to the placebo-treated animals, the vaccinated calves did not lose any weight, which is an excellent indicator of the well-being of an animal and has a significant economic impact. Furthermore, the interval between the two vaccinations did not influence the magnitude of the immune responses or degree of clinical protection, and a third immunization was not necessary or beneficial. Since electroporation may enhance not only the magnitude but also the duration of immunity after DNA immunization, the interval between vaccination and challenge was extended in a second trial, which showed that two doses of this E2 DNA vaccine again significantly reduced clinical disease against BVDV for several months. These results are promising and support this technology for use against infectious diseases in cattle and large species, including humans, in general.

  3. Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'

    Science.gov (United States)

    Salter, Bill J.; Sarkar, Vikren; Wang, Brian; Shukla, Himanshu; Szegedi, Martin; Rassiah-Szegedi, Prema

    2011-04-01

    Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units per minute (MU min-1) high dose rate bursts of dose are facilitated by a flattening-filter-free treatment beam on a Siemens Artiste (Oncology Care Systems, Siemens Medical Solutions, Concord, CA, USA) digital linear accelerator in a non-clinical configuration. Burst mode delivery differs from continuous mode delivery, used by Elekta's VMAT (Elekta Ltd, Crawley, UK) and Varian's RapidArc (Varian Medical Systems, Palo Alto, CA, USA) implementations, in that dose is not delivered while MLC leaves are moving. Instead, dose is delivered in bursts over very short arc angles and only after an MLC segment shape has been completely formed and verified by the controller. The new system was confirmed to be capable of delivering a wide array of clinically relevant treatment plans, without machine fault or other delivery anomalies. Dosimetric accuracy of the modulated arc platform, as well as the Prowess (Prowess Inc., Concord, CA, USA) prototype treatment planning version utilized here, was quantified and confirmed, and delivery times were measured as significantly brief, even with large hypofractionated doses. The burst mode modulated arc approach evaluated here appears to represent a capable, accurate and efficient delivery approach.

  4. Quality control of high-dose-rate brachytherapy: treatment delivery analysis using statistical process control.

    Science.gov (United States)

    Able, Charles M; Bright, Megan; Frizzell, Bart

    2013-03-01

    Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Quality Control of High-Dose-Rate Brachytherapy: Treatment Delivery Analysis Using Statistical Process Control

    Energy Technology Data Exchange (ETDEWEB)

    Able, Charles M., E-mail: cable@wfubmc.edu [Department of Radiation Oncology, Wake Forest School of Medicine, Winston-Salem, North Carolina (United States); Bright, Megan; Frizzell, Bart [Department of Radiation Oncology, Wake Forest School of Medicine, Winston-Salem, North Carolina (United States)

    2013-03-01

    Purpose: Statistical process control (SPC) is a quality control method used to ensure that a process is well controlled and operates with little variation. This study determined whether SPC was a viable technique for evaluating the proper operation of a high-dose-rate (HDR) brachytherapy treatment delivery system. Methods and Materials: A surrogate prostate patient was developed using Vyse ordnance gelatin. A total of 10 metal oxide semiconductor field-effect transistors (MOSFETs) were placed from prostate base to apex. Computed tomography guidance was used to accurately position the first detector in each train at the base. The plan consisted of 12 needles with 129 dwell positions delivering a prescribed peripheral dose of 200 cGy. Sixteen accurate treatment trials were delivered as planned. Subsequently, a number of treatments were delivered with errors introduced, including wrong patient, wrong source calibration, wrong connection sequence, single needle displaced inferiorly 5 mm, and entire implant displaced 2 mm and 4 mm inferiorly. Two process behavior charts (PBC), an individual and a moving range chart, were developed for each dosimeter location. Results: There were 4 false positives resulting from 160 measurements from 16 accurately delivered treatments. For the inaccurately delivered treatments, the PBC indicated that measurements made at the periphery and apex (regions of high-dose gradient) were much more sensitive to treatment delivery errors. All errors introduced were correctly identified by either the individual or the moving range PBC in the apex region. Measurements at the urethra and base were less sensitive to errors. Conclusions: SPC is a viable method for assessing the quality of HDR treatment delivery. Further development is necessary to determine the most effective dose sampling, to ensure reproducible evaluation of treatment delivery accuracy.

  6. Delivering high-resolution landmarks using inkjet micropatterning for spatial monitoring of leaf expansion

    Directory of Open Access Journals (Sweden)

    Cronk Quentin CB

    2011-01-01

    printed at these scales. Conclusions To apply inkjet micropatterning to plant studies, we have successfully delivered landmarks on ivy leaf surfaces and achieved high-resolution, two-dimensional monitoring of leaf expansion at different growing stages. The measurement is capable of reliably identifying the fine scale changes during plant growth. As well as delivering landmarks, this technology may be used to deliver microscale targeted biological components such as growth hormones, and possibly be used to pattern sensors directly on the leaves.

  7. High-Dose Statins Boost Survival

    Science.gov (United States)

    ... atorvastatin (Lipitor) or 20 to 40 mg of rosuvastatin (Crestor) daily. Examples of moderate doses include 10 to ... of Lipitor and 5 to 10 mg of Crestor, the study reported. Unlike some previous studies, this ...

  8. Dose tailoring of anti-tumour necrosis factor-alpha therapy delivers useful clinical efficacy in Crohn disease patients experiencing loss of response.

    Science.gov (United States)

    Ghaly, S; Costello, S; Beswick, L; Pudipeddi, A; Agarwal, A; Sechi, A; Antoniades, S; Headon, B; Connor, S; Lawrance, I C; Sparrow, M; Walsh, A J; Andrews, J M

    2015-02-01

    'Dose tailoring' of anti-tumour necrosis factor alpha (TNF-α) therapy in Crohn disease (CD), by dose escalation, or shortening of dosing intervals, has been suggested to regain clinical response following a flare in a proportion of patients. However, reported outcome data are sparse and none exists from Australia. In an observational multicentre, retrospective study, the impact of anti-TNF-α dose tailoring on corticosteroid use, the need for surgery and physician perception of clinical efficacy was examined in a real-world setting at six Australian adult teaching hospitals. Demographics, disease characteristics, medications, indication for and duration of dose tailoring were documented. Fifty-five CD patients were identified as requiring dose tailoring and secondary loss of response was the indication in 96%. Either adalimumab (64%) or infliximab (36%) was dose escalated for a median of 5 months (range 1-47), with a median of 20 months follow up (range 3-65). At 3 months, dose tailoring reduced the mean number of days on high-dose corticosteroids (45 vs 23, P = 0.01). Most (78%) patients remained resection free, and 73% of physicians reported good clinical efficacy of dose tailoring. Of those who de-escalated therapy due to induction of remission, long-term (>12 months) follow up and complete data on steroid use were available in 15/28, with 12/15 (80%) remaining steroid free at 1 year. Short-term dose tailoring regains disease response in the majority of patients with CD. Of these, most will remain free of corticosteroids at 1 year after de-escalating therapy. © 2014 Royal Australasian College of Physicians.

  9. High dose rate endobronchial brachytherapy: a curative treatment; La curietherapie endobronchique de haut debit de dose: un traitement curatif

    Energy Technology Data Exchange (ETDEWEB)

    Peiffert, D.; Spaeth, D.; Winnefeld, J. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France); Menard, O. [Centre Hospitalier Universitaire Nancy-Brabois, 54 - Vandoeuvre-les-Nancy (France)

    2000-06-01

    New endobronchial techniques of treatment allow a good unblocking. Nevertheless, only high dose rate brachytherapy delivers a curative treatment for invasive carcinomas. This study analyses the results of the first 33 consecutive patients treated with curative intent by this technique from 1994 to 1997, and followed-up more than one year. Thirty-seven lesions were treated, with usual schedule delivering 30 Gy at 1 cm depth in six fractions and three to five weeks. All the patients were meticulously selected on the local involvement of the tumour and absolute contraindications to a surgical treatment. All of them have a pulmonary disease history or a general contraindication. With a 14-month follow-up, the local control at two months after the treatment was 95 % (endoscopic and histologic), and 90 % of the patients presented a prolonged local control. Four patients died of the treated cancer, another of a controlateral cancer. Ten patients died of another disease, five of them from a respiratory insufficiency. The overall survival rate at two years was 53 % and the specific survival rate 80 %. The acute tolerance was good, without incident. Asymptomatic bronchial stenoses, described by endoscopic follow-up, were described for seven patients. We conclude that, on the basis of a good selection of the patients, and a respect of the indications, high dose rate endobronchial brachytherapy is an effective curative treatment. It offers a new curative option and must be proposed for the small invasive carcinomas in non-operable patients. (author)

  10. Biological dose estimation for accidental supra-high dose gamma-ray exposure

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y., E-mail: yingchen29@yahoo.com.cn [Department of Radiation Toxicology and Oncology, Beijing Institute of Radiation Medicine, 27 Taiping Road, Haidian District, Beijing 100850 (China); Yan, X.K. [Department of Radiation Toxicology and Oncology, Beijing Institute of Radiation Medicine, 27 Taiping Road, Haidian District, Beijing 100850 (China); Department of Radiation Safety, Beijing Institute of Nuclear and Chemical Safety, 14 Guan-cun, Dongcheng District, Beijing 100077 (China); Du, J.; Wang, Z.D.; Zhang, X.Q.; Zeng, F.G.; Zhou, P.K. [Department of Radiation Toxicology and Oncology, Beijing Institute of Radiation Medicine, 27 Taiping Road, Haidian District, Beijing 100850 (China)

    2011-09-15

    To correctly estimate the biological dose of victims accidentally exposed to a very high dose of {sup 60}Co gamma-ray, a new dose-effect curve of chromosomal dicentrics/multicentrics and rings in the supra-high dose range was established. Peripheral blood from two healthy men was irradiated in vitro with doses of {sup 60}Co gamma-rays ranging from 6 to 22 Gy at a dose rate of 2.0 Gy/min. Lymphocytes were concentrated, cultured and harvested at 52 h, 68 h and 72 h. The numbers of dic + r were counted. The dose-effect curves were established and validated using comparisons with doses from the Tokai-mura accident and were then applied to two victims of supra-high dose exposure accident. The results indicated that there were no significant differences in chromosome aberration frequency among the different culture times from 52 h to 72 h. The 6-22 Gy dose-effect curve was fitted to a linear quadratic model Y = -2.269 + 0.776D - 7.868 x l0{sup -3}D{sup 2}. Using this mathematic model, the dose estimates were similar to data from Tokai-mura which were estimated by PCC ring. Whole body average doses of 9.7 Gy and 18.1 Gy for two victims in the Jining accident were satisfactorily given. We established and successfully applied a new dose-effect curve of chromosomal dicentrics plus ring (dic + r) after 6-22 Gy {gamma}-irradiation from a supra-high dose {sup 60}Co gamma-ray accident.

  11. The transit dose component of high dose rate brachytherapy: Direct measurements and clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Bastin, K.T.; Podgorsak, M.B.; Thomadsen, B.R. (Univ. of Wisconsin Hospitals and Clinics, Madison, WI (United States))

    1993-07-15

    The purpose was to measure the transit dose produced by a moving high dose rate brachytherapy source and assess its clinical significance. The doses produced from source movement during Ir-192 HDR afterloading were measured using calibrated thermoluminescent dosimeter rods. Transit doses at distances of 0.5-4.0 cm from an endobronchial applicator were measured using a Lucite phantom accommodating 1 x 1 x 6 mm thermoluminescent rods. Surface transit dose measurements were made using esophageal and endobronchial catheters, a gynecologic tandem, and an interstitial needle. No difference was detected in thermoluminescent dosimeter rod responses to 4 MV and Ir-192 spectra (427 nC/Gy) in a range of dose between 2 and 300 cGy. The transit dose at 0.5 cm from an endobronchial catheter was 0.31 cGy/(Curie-fraction) and followed an inverse square fall-off with increasing distance. Surface transit doses ranged from 0.38 cGy/(Curie-fraction) for an esophageal catheter to 1.03 cGy/(Curie-fraction) for an endobronchial catheter. Source velocity is dependent on the interdwell distance and varies between 220-452 mm/sec. A numeric algorithm was developed to calculate total transit dose, and was based on a dynamic point approximation for the moving high dose rate source. This algorithm reliably predicted the empirical transit doses and demonstrated that total transit dose is dependent on source velocity, number of fractions, and source activity. Surface transit doses are dependent on applicator diameter and wall material and thickness. Total transit doses within or outside the desired treatment volume are typically <100 cGy, but may exceed 200 cGy when using a large number of fractions with a high activity source. 9 refs., 8 figs., 1 tab.

  12. High dose radiotherapy for pituitary tumours

    Energy Technology Data Exchange (ETDEWEB)

    Mead, K.W. (Queensland Radium Inst., Herston (Australia))

    1981-11-01

    The results of treatment of 120 pituitary tumours are presented. Based on this experience operable chromophobe adenomas are now treated with 5,000 rads in 4 weeks and inoperable ones receive an additional central dose to 7,500 rads. Pituitary Cushing's tumours are given 10,000 rads in 5 weeks using small fields and acromegalics 5,000 rads to the whole sella and 7,500 to its lower half. The absence of complications at these dose levels is attributed to the use of small fields and the precise application of treatment.

  13. Industrial grade fiber-coupled laser systems delivering ultrashort high-power pulses for micromachining

    Science.gov (United States)

    Pricking, Sebastian; Welp, Petra; Overbuschmann, Johannes; Nutsch, Sebastian; Gebs, Raphael; Fleischhaker, Robert; Kleinbauer, Jochen; Wolf, Martin; Budnicki, Aleksander; Sutter, Dirk H.; Killi, Alexander; Mielke, Michael

    2016-03-01

    We report on an industrial fiber-delivered laser system producing ultra-short pulses in the range of a few picoseconds down to a few hundred femtoseconds with high average power suitable for high-precision micromachining. The delivery fiber is a hollow-core photonic crystal fiber with a Kagomé shaped lattice and a hypocycloid core wall enabling the guiding of laser radiation over several meters with exceptionally low losses and preservation of high beam quality (M2laser head providing a compact footprint without the need for external boxes. The laser head is carefully designed regarding its thermo-mechanical properties to allow a highly reliable coupling stability. The exchangeable delivery fiber is packaged using Trumpf's well established LLK-D connectors which offer a very high mechanical precision, the possibility to add water cooling, as well as full featured safety functions. The fiber is hermetically sealed and protected by a robust but flexible shield providing bend protection and break detection. We show the linear and nonlinear optical properties of the transported laser radiation and discuss its feasibility for pulse compression. Measurements are supported by simulation of pulse propagation by solving the nonlinear Schrödinger equation implementing the split-step Fourier method. In addition, mode properties are measured and confirmed by finite element method simulations. The presented industrial laser system offers the known advantages of ultra-short pulses combined with the flexibility of fiber delivery yielding a versatile tool perfectly suitable for all kinds of industrial micromachining applications.

  14. Relative safety profiles of high dose statin regimens

    Directory of Open Access Journals (Sweden)

    Carlos Escobar

    2008-06-01

    Full Text Available Carlos Escobar, Rocio Echarri, Vivencio BarriosDepartment of Cardiology, Hospital Ramón y Cajal, Madrid, SpainAbstract: Recent clinical trials recommend achieving a low-density lipoprotein cholesterol level of <100 mg/dl in high-risk and <70 mg/dl in very high risk patients. To attain these goals, however, many patients will need statins at high doses. The most frequent side effects related to the use of statins, myopathy, rhabdomyolysis, and increased levels of transaminases, are unusual. Although low and moderate doses show a favourable profile, there is concern about the tolerability of higher doses. During recent years, numerous trials to analyze the efficacy and tolerability of high doses of statins have been published. This paper updates the published data on the safety of statins at high doses.Keywords: statins, high doses, tolerability, liver, muscle

  15. Statistical behavior of high doses in medical radiodiagnosis; Comportamento estatistico das altas doses em radiodiagnostico medico

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Adriana Elisa, E-mail: adrianaebarboza@gmail.com, E-mail: elisa@bolsista.ird.gov.br [Instituto de Radioprotecao e Dosimetria, (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2014-07-01

    This work has as main purpose statistically estimating occupational exposure in medical diagnostic radiology in cases of high doses recorded in 2011 at national level. For statistical survey of this study, doses of 372 IOE's diagnostic radiology in different Brazilian states were evaluated. Data were extracted from the work of monograph (Research Methodology Of High Doses In Medical Radiodiagnostic) that contains the database's information Sector Management doses of IRD/CNEN-RJ, Brazil. The identification of these states allows the Sanitary Surveillance (VISA) responsible, becomes aware of events and work with programs to reduce these events. (author)

  16. Automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy

    Science.gov (United States)

    Yeap, P. L.; Noble, D. J.; Harrison, K.; Bates, A. M.; Burnet, N. G.; Jena, R.; Romanchikova, M.; Sutcliffe, M. P. F.; Thomas, S. J.; Barnett, G. C.; Benson, R. J.; Jefferies, S. J.; Parker, M. A.

    2017-08-01

    To determine delivered dose to the spinal cord, a technique has been developed to propagate manual contours from kilovoltage computed-tomography (kVCT) scans for treatment planning to megavoltage computed-tomography (MVCT) guidance scans. The technique uses the Elastix software to perform intensity-based deformable image registration of each kVCT scan to the associated MVCT scans. The registration transform is then applied to contours of the spinal cord drawn manually on the kVCT scan, to obtain contour positions on the MVCT scans. Different registration strategies have been investigated, with performance evaluated by comparing the resulting auto-contours with manual contours, drawn by oncologists. The comparison metrics include the conformity index (CI), and the distance between centres (DBC). With optimised registration, auto-contours generally agree well with manual contours. Considering all 30 MVCT scans for each of three patients, the median CI is 0.759 +/- 0.003 , and the median DBC is (0.87 +/- 0.01 ) mm. An intra-observer comparison for the same scans gives a median CI of 0.820 +/- 0.002 and a DBC of (0.64 +/- 0.01 ) mm. Good levels of conformity are also obtained when auto-contours are compared with manual contours from one observer for a single MVCT scan for each of 30 patients, and when they are compared with manual contours from six observers for two MVCT scans for each of three patients. Using the auto-contours to estimate organ position at treatment time, a preliminary study of 33 patients who underwent radiotherapy for head-and-neck cancers indicates good agreement between planned and delivered dose to the spinal cord.

  17. How can we deliver high-quality cancer care in a healthcare system in crisis?

    Science.gov (United States)

    Mayer, Deborah K

    2014-08-01

    This provocative question was addressed in a report from the Institute of Medicine ([IOM], 2013), Delivering High-Quality Cancer Care: Charting a New Course for a System in Crisis. An interdisciplinary committee synthesized many of the changes that are occurring in our society and health care that will challenge our existing cancer care system. These changes are familiar to many of us: an aging population along with the resulting increase in the number of cancer survivors, an inadequate number of and increased demand for trained healthcare providers, and rising healthcare costs. The IOM report recommended a framework of six interconnected components for improving the quality of cancer care (see Figures 1 and 2). Each of these components is worthy of an editorial and more. I would like to focus, however, on one of them: an adequately staffed, trained, and coordinated workforce. And, for good reason, as I want to retire someday and know that others will be taking my place in caring for cancer survivors across the care continuum. So let's explore this one component in more detail.

  18. Experiences of high dose rate interstitial brachytherapy for carcinoma of the mobile tongue

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Hiroshi; Inoue, Toshihiko; Yamazaki, Hideya (Osaka Univ. (Japan). Faculty of Medicine) (and others)

    1994-03-01

    Interstitial brachytherapy was conducted for mobile tongue carcinoma using a high dose rate remote afterloading machine with small [sup 192]I source. Detailed method, named as 'linked double-botton technique', is to approach from submandibular skin by an open-ended stainless steel needles to the tongue lesion, and to replace each needle into flexible nylon tube from the oral cavity. Delivered dose was 60 Gy/10 Fr./5-6 days at the distance 5 mm from the source plane. Ten patients with mobile tongue carcinoma Tl-2N0 were treated with this method from October 1991 through August 1992. Local was uncontrolled in one patient, in whom the lesion was combined with leukoplakia at both lateral borders of the tongue. This was in accordance with the result in low dose rate treatment. This can be a substitute to low dose rate system for treatment of mobile tongue carcinoma. (author).

  19. Investigating quartz optically stimulated luminescence dose-response curves at high doses

    Energy Technology Data Exchange (ETDEWEB)

    Lowick, Sally E., E-mail: lowick@geo.unibe.c [Institut fuer Geologie, Universitaet Bern, Baltzerstrasse 1-3, 3012 Bern (Switzerland); Preusser, Frank [Institut fuer Geologie, Universitaet Bern, Baltzerstrasse 1-3, 3012 Bern (Switzerland); Wintle, Ann G. [Institute of Geography and Earth Sciences, Aberystwyth University, AberystwythSY23 3DB (United Kingdom)

    2010-10-15

    Despite the general expectation that optically stimulated luminescence (OSL) growth should be described by a simple saturating exponential function, an additional high dose component is often reported in the dose response of quartz. Although often reported as linear, it appears that this response is the early expression of a second saturating exponential. While some studies using equivalent doses that fall in this high dose region have produced ages that correlate well with independent dating, others report that it results in unreliable age determinations. Two fine grain sedimentary quartz samples that display such a response were used to investigate the origin of this additional high dose component: three experiments were conducted to examine their dose-response up to >1000 Gy. The high dose rates provided by laboratory irradiation were found not to induce a sensitivity change in the response to a subsequent test dose, with the latter not being significantly different from those generated following naturally acquired doses. The relative percentage contributions of the fast and medium OSL components remained fixed throughout the dose-response curve, suggesting that the electron traps that give rise to the initial OSL do not change with dose. An attempt was made to investigate a change in luminescence centre recombination probability by monitoring the depletion of the '325 {sup o}C' thermoluminescence (TL) during the optical stimulation that would result in depletion of the OSL signal. The emissions measured through both the conventional ultraviolet (UV), and a longer wavelength violet/blue (VB) window, displayed similar relative growth with dose, although it was not possible to resolve the origin of the VB emissions. No evidence was found to indicate whether the additional component at high doses occurs naturally or is a product of laboratory treatment. However, it appears that these samples display an increased sensitivity of quartz OSL to high doses

  20. Prostate radiation therapy: In vivo measurement of the dose delivered by kV-C.B.C.T; Radiotherapie des cancers de la prostate: evaluation in vivo de la dose delivree par tomographie conique de basse energie (kV)

    Energy Technology Data Exchange (ETDEWEB)

    Marinello, G.; Mege, J.P.; Besse, M.C.; Kerneur, G. [CHU Henri-Mondor, Unite de Radiophysique et de Radioprotection du Patient, 94 - Creteil (France); Lagrange, J.L. [CHU Henri-Mondor, Service de Radiotherapie, 94 - Creteil (France); Paris-12 Univ., 94 - Creteil (France)

    2009-09-15

    Purpose: To investigate if the regular use of kilo voltage cone beam computed tomography (kV-C.B.C.T.) notably increases the dose delivered to tumor and surrounding healthy tissues. Material and methods: Images were obtained using a Varian equipment (O.B.I. version 1.3, 645 to 650 projections in 370 degrees to acquire image), and patients were irradiated at source-tumor distance: 100 cm. In vivo measurements were performed using radio-thermoluminescent dosimeters Harshaw-TLD 700 H (TLD) at skin (anterior-posterior and lateral axis crossing the rotation axis), with a fourth TLD group under the table thanks to a retro-laser. TLD were calibrated at the kV-C.B.C.T. effective energy (64 keV), and the method validated using an anthropomorphic phantom, in which Gafchromic E.B.T. films were also inserted. Results: The phantom study showed that the dose distribution depends on the phantom position relative to the axis and that the doses measured at the phantom surface using TLD and films (good agreement) were maximum at the entrance of the anterior-posterior axis. Their arithmetic mean was equal, or a slightly greater than doses measured at mid-thickness of the phantom and at the level of the rectum (O.A.R., organ at risk). In vivo measurements performed on the five first patients (125 kV-C.B.C.T.) yield a mean skin dose per kV-C.B.C.T. varying from 5.8 {+-} 0.1 to 7.3 {+-} 0.2 c Gy on the anterior-posterior axis. Lateral skin doses vary from 3.4{+-}0.2 to 4.5 {+-} 0.2 c Gy. Conclusion: Doses delivered by repeated kV-C.B.C.T. are not negligible. They should be taken into account, but questions about the RBE to be applied to kilo voltage X-rays are raised. (authors)

  1. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  2. SU-E-T-165: Characterization of Dose Distributions in High-Dose-Rate Surface Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Buzurovic, I; Hansen, J; Bhagwat, M; O’Farrell, D; Damato, A; Friesen, S; Devlin, P; Cormack, R [Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Boston, MA (United States)

    2015-06-15

    Purpose: To characterize dose distributions in high-dose-rate(HDR) surface brachytherapy using an Ir-125 source for different geometries, field sizes and topology of the clinical targets(CT). To investigate the depth doses at the central axis(CAX), edges of the treatment fields(E), and lateral dose distributions(L) present when using flap applicators in skin cancer treatments. Methods: When malignancies diagnosed on the skin are treated, various geometries of the CT require proper adaptation of the flap or custom-made applicators to the treatment site. Consequently, the dose at the depth on CAX and field edges changes with variation of the curvatures and size of the applicators. To assess the dose distributions, we created a total of 10 treatment plans(TP) for 10×10 and 20×20 field sizes(FS) with a step size of 1cm. The geometry of the applicators was: planar(PA), curved to 30(CA30) and 60(CA60) degrees with respect to the CAX, half-cylinder(HC), and cylindrical shape(CS). One additional TP was created in which the applicators were positioned to form a dome shape(DS) with a diameter of 16cm. This TP was used to emulate treatment of the average sized scalp. All TPs were optimized to deliver a prescription dose at 8mm equidistantly from the planes containing the dwell positions. This optimization is equivalent to the clinical arrangement since the SSD for the flap applicators is 5mm and the prescription depth is 3mm in the majority of clinical cases. Results: The depths (in mm) of the isodose lines were: FS(10×10):PA[90%(9.1CAX,8.0E,7.6L),50%(28.3CAX,20E,17.3L), 25%(51.1CAX,40E,27L)],CA30[90%(10.3CAX,8.2E,7.9L),50%(32.1CAX, 16.2E,15.8L),25%(61.3CAX,36.7E,31.8L)],CA60[90%(12.2CAX,6.1E,6.3L ),50%(47CAX,14E,16.6L),25%(70.8CAX,31.9E,35.4L)],HC[90%(11.1CA X,6.3E,7.3L),50%(38.3CAX,14.6E,16.1L),25%(66.2CAX,33.8E,34.2L)];FS (20×20):PA[90%(11.1CAX,9.0E,7.0L),50%(34.4CAX,21.9E,15.3L),25%(7 0.4CAX,50.9E,34.8L)],CA30[90%(10.9CAX,7.5E,7.1L),50%(38.8CAX,16. 7E,15.4L),25

  3. Fertility of Tall Girls Treated with High-Dose Estrogen, a Dose-Response Relationship

    NARCIS (Netherlands)

    Hendriks, A. E. J.; Drop, S. L. S.; Laven, J. S. E.; Boot, A. M.

    2012-01-01

    Context: High-dose estrogen treatment to reduce final height of tall girls increases their risk for infertility in later life. Objective: The aim was to study the effect of estrogen dose on fertility outcome of these women. Design/Setting: We conducted a retrospective cohort study of university hosp

  4. Clinical implementation of a novel applicator in high-dose-rate brachytherapy treatment of esophageal cancer

    Directory of Open Access Journals (Sweden)

    Ivan M. Buzurovic

    2016-08-01

    Full Text Available Purpose : In this study, we present the clinical implementation of a novel transoral balloon centering esophageal applicator (BCEA and the initial clinical experience in high-dose-rate (HDR brachytherapy treatment of esophageal cancer, using this applicator. Material and methods: Acceptance testing and commissioning of the BCEA were performed prior to clinical use. Full performance testing was conducted including measurements of the dimensions and the catheter diameter, evaluation of the inflatable balloon consistency, visibility of the radio-opaque markers, congruence of the markers, absolute and relative accuracy of the HDR source in the applicator using the radiochromic film and source position simulator, visibility and digitization of the applicator on the computed tomography (CT images under the clinical conditions, and reproducibility of the offset. Clinical placement of the applicator, treatment planning, treatment delivery, and patient’s response to the treatment were elaborated as well. Results : The experiments showed sub-millimeter accuracy in the source positioning with distal position at 1270 mm. The digitization (catheter reconstruction was uncomplicated due to the good visibility of markers. The treatment planning resulted in a favorable dose distribution. This finding was pronounced for the treatment of the curvy anatomy of the lesion due to the improved repeatability and consistency of the delivered fractional dose to the patient, since the radioactive source was placed centrally within the lumen with respect to the clinical target due to the five inflatable balloons. Conclusions : The consistency of the BCEA positioning resulted in the possibility to deliver optimized non-uniform dose along the catheter, which resulted in an increase of the dose to the cancerous tissue and lower doses to healthy tissue. A larger number of patients and long-term follow-up will be required to investigate if the delivered optimized treatment can

  5. Relevance of high-dose chemotherapy in solid tumours

    NARCIS (Netherlands)

    Nieboer, P; de Vries, EGE; Mulder, NH; van der Graaf, WTA

    2005-01-01

    Drug resistance is a major problem in the treatment of solid tumours. Based on a steep dose-response relationship for especially alkylating agents on tumour cell survival, high-dose chemotherapy was considered of interest for the treatment of solid tumours. Results of phase 1 and 2 studies with high

  6. Pharmacogenetics and Pharmacokinetics in high-dose alkylating chemotherapy

    NARCIS (Netherlands)

    Ekhart, G.C. (Corine)

    2008-01-01

    High-dose chemotherapy in combination with peripheral blood progenitor cell transplantation has been developed as a possible curative treatment modality in several solid tumours. A frequently used high-dose regimen in the Netherlands is the CTC regimen, which is a 4-day course of cyclophosphamide, t

  7. High-resolution low-dose scanning transmission electron microscopy.

    Science.gov (United States)

    Buban, James P; Ramasse, Quentin; Gipson, Bryant; Browning, Nigel D; Stahlberg, Henning

    2010-01-01

    During the past two decades instrumentation in scanning transmission electron microscopy (STEM) has pushed toward higher intensity electron probes to increase the signal-to-noise ratio of recorded images. While this is suitable for robust specimens, biological specimens require a much reduced electron dose for high-resolution imaging. We describe here protocols for low-dose STEM image recording with a conventional field-emission gun STEM, while maintaining the high-resolution capability of the instrument. Our findings show that a combination of reduced pixel dwell time and reduced gun current can achieve radiation doses comparable to low-dose TEM.

  8. High dose brachytherapy in pediatric oncology; Braquiterapia com alta taxa de dose em oncologia pediatrica

    Energy Technology Data Exchange (ETDEWEB)

    Ferrigno, Robson; Codjaian, Osanna Esther; Novaes, Paulo Eduardo R.S.; Trippe, Nivaldo [Fundacao Antonio Prudente, Sao Paulo, SP (Brazil). Hospital A.C. Camargo. Dept. de Radioterapia

    1995-05-01

    Brachytherapy is a kind of radiotherapy that has been used in the multidisciplinary approach of some pediatric tumors, such as soft tissue sarcomas of the extremities, head and neck and urogenital tract. Recent technological advances in this area lead to development of computerized high dose rate remote afterloading brachytherapy. This type of treatment has some advantages compared to low dose rate brachytherapy traditionally used. This article describes not only the characteristics and advantages of this kind of treatment, but also the preliminary results of the first seven children treated with high dose rate at the Hospital A.C.Camargo. (author) 10 refs., 8 figs.

  9. Accelerated Irradiations for High Dose Microstructures in Fast Reactor Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Zhijie [Univ. of Michigan, Ann Arbor, MI (United States)

    2017-03-31

    The objective of this project is to determine the extent to which high dose rate, self-ion irradiation can be used as an accelerated irradiation tool to understand microstructure evolution at high doses and temperatures relevant to advanced fast reactors. We will accomplish the goal by evaluating phase stability and swelling of F-M alloys relevant to SFR systems at very high dose by combining experiment and modeling in an effort to obtain a quantitative description of the processes at high and low damage rates.

  10. High-dose dosimetry using natural silicate minerals

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Lucas S. do; Mendes, Leticia, E-mail: isatiro@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Watanabe, Shigueo; Rao, Gundu; Lucas, Natasha; Sato, Karina, E-mail: lacifid@if.usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Fisica. Departamento de Fisica Nuclear; Barbosa, Renata F., E-mail: profcelta@hotmail.com [Universidade Federal de Sao Paulo (UNIFESP), Santos, SP (Brazil). Departamento de Ciencias do Mar

    2015-07-01

    In the present study, certain natural silicate minerals such as aquamarine (AB), morganite (PB), goshenite (WB), white jadeite (JW), green jadeite (JG), pink tourmaline (PT) and two varieties of jadeite-like quartz, denoted here by JQ1 and JQ2, were investigated using the thermoluminescence technique to evaluate their potential for use as very-high- and high-dose dosimeters. These minerals respond to high doses of γ-rays of up to 1000 kGy and often to very high doses of up to 3000 kGy. The TL response of these minerals may be considered to be satisfactory for applications in high-dose dosimetry. Investigations of electron paramagnetic resonance and optically stimulated luminescence dosimetry are in progress. (author)

  11. Three-dimensional conformal radiation for esophageal squamous cell carcinoma with involved-field irradiation may deliver considerable doses of incidental nodal irradiation

    Directory of Open Access Journals (Sweden)

    Ji Kai

    2012-11-01

    Full Text Available Abstract Background To quantify the incidental irradiation dose to esophageal lymph node stations when irradiating T1-4N0M0 thoracic esophageal squamous cell carcinoma (ESCC patients with a dose of 60 Gy/30f. Methods Thirty-nine patients with medically inoperable T1–4N0M0 thoracic ESCC were treated with three-dimensional conformal radiation (3DCRT with involved-field radiation (IFI. The conformal clinical target volume (CTV was re-created using a 3-cm margin in the proximal and distal direction beyond the barium esophagogram, endoscopic examination and CT scan defined the gross tumor volume (GTV and a 0.5-cm margin in the lateral and anteroposterior directions of the CT scan-defined GTV. The PTV encompassed 1-cm proximal and distal margins and 0.5-cm radial margin based on the CTV. Nodal regions were delineated using the Japanese Society for Esophageal Diseases (JSED guidelines and an EORTC-ROG expert opinion. The equivalent uniform dose (EUD and other dosimetric parameters were calculated for each nodal station. Nodal regions with a metastasis rate greater than 5% were considered a high-risk lymph node subgroup. Results Under a 60 Gy dosage, the median Dmean and EUD was greater than 40 Gy in most high-risk nodal regions except for regions of 104, 106tb-R in upper-thoracic ESCC and 101, 104-R, 105, 106rec-L, 2, 3&7 in middle-thoracic ESCC and 107, 3&7 in lower-thoracic ESCC. In the regions with an EUD less than 40Gy, most incidental irradiation doses were significantly associated with esophageal tumor length and location. Conclusions Lymph node stations near ESCC receive considerable incidental irradiation doses with involved-field irradiation that may contribute to the elimination of subclinical lesions.

  12. High-Dose Vitamin D May Not Curb Kids' Colds

    Science.gov (United States)

    ... medlineplus.gov/news/fullstory_167275.html High-Dose Vitamin D May Not Curb Kids' Colds Study seems ... 18, 2017 (HealthDay News) -- When it comes to vitamin supplements, more is not always better, according to ...

  13. Patient-specific dose calculation methods for high-dose-rate iridium-192 brachytherapy

    Science.gov (United States)

    Poon, Emily S.

    In high-dose-rate 192Ir brachytherapy, the radiation dose received by the patient is calculated according to the AAPM Task Group 43 (TG-43) formalism. This table-based dose superposition method uses dosimetry parameters derived with the radioactive 192Ir source centered in a water phantom. It neglects the dose perturbations caused by inhomogeneities, such as the patient anatomy, applicators, shielding, and radiographic contrast solution. In this work, we evaluated the dosimetric characteristics of a shielded rectal applicator with an endocavitary balloon injected with contrast solution. The dose distributions around this applicator were calculated by the GEANT4 Monte Carlo (MC) code and measured by ionization chamber and GAFCHROMIC EBT film. A patient-specific dose calculation study was then carried out for 40 rectal treatment plans. The PTRAN_CT MC code was used to calculate the dose based on computed tomography (CT) images. This study involved the development of BrachyGUI, an integrated treatment planning tool that can process DICOM-RT data and create PTRAN_CT input initialization files. BrachyGUI also comes with dose calculation and evaluation capabilities. We proposed a novel scatter correction method to account for the reduction in backscatter radiation near tissue-air interfaces. The first step requires calculating the doses contributed by primary and scattered photons separately, assuming a full scatter environment. The scatter dose in the patient is subsequently adjusted using a factor derived by MC calculations, which depends on the distances between the point of interest, the 192Ir source, and the body contour. The method was validated for multicatheter breast brachytherapy, in which the target and skin doses for 18 patient plans agreed with PTRAN_CT calculations better than 1%. Finally, we developed a CT-based analytical dose calculation method. It corrects for the photon attenuation and scatter based upon the radiological paths determined by ray tracing

  14. High-dose vs low-dose oxytocin for labor augmentation: a systematic review.

    Science.gov (United States)

    Wei, Shu-Qin; Luo, Zhong-Cheng; Qi, Hui-Ping; Xu, Hairong; Fraser, William D

    2010-10-01

    The objective of this systematic review was to estimate the efficacy and safety of high-dose vs low-dose oxytocin for labor augmentation on the risk of cesarean section and on indicators of maternal and neonatal morbidity. We searched PubMed, MEDLINE, EMBASE, and the Cochrane Library for randomized clinical trials published until January 2010. Ten randomized clinical trials, including 5423 women, met the inclusion criteria. High-dose oxytocin was associated with a moderate decrease in the risk of cesarean section (relative risk [RR], 0.85; 95% confidence interval [CI], 0.75-0.97), a small increase in spontaneous vaginal delivery (RR, 1.07; 95% CI, 1.02-1.12), and a decrease in labor duration (mean difference: -1.54 hours, 95% CI, -2.44 to -0.64). While hyperstimulation was increased with high-dose oxytocin (RR, 1.91; 95% CI, 1.49-2.45), there was no evidence of an increase in maternal or neonatal morbidity. We conclude that high-dose oxytocin for labor augmentation is associated with a decrease in cesarean section and shortened labor. Copyright © 2010 Mosby, Inc. All rights reserved.

  15. High-dose neutron detector development

    Energy Technology Data Exchange (ETDEWEB)

    Henzlova, Daniela [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Menlove, Howard Olsen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-01-14

    The development of advanced sustainable nuclear fuel cycles relying on used nuclear fuel is one of the key programs pursued by the DOE Office of Nuclear Energy to minimize waste generation, limit proliferation risk and maximize energy production using nuclear energy. Safeguarding of advanced nuclear fuel cycles is essential to ensure the safety and security of the nuclear material. Current non-destructive assay (NDA) systems typically employ fission chambers or 3He-based tubes for the measurement of used fuel. Fission chambers are capable of withstanding the high gamma-ray backgrounds; however, they provide very low detection efficiency on the order of 0.01%. To benefit from the additional information provided by correlated neutron counting [1] higher detection efficiencies are required. 3He-based designs allow for higher detection efficiencies; however, at the expense of slow signal rise time characteristics and higher sensitivity to the gamma-ray backgrounds. It is therefore desirable to evaluate and develop technologies with potential to exceed performance parameters of standard fission chamber-based or 3He-based detection systems currently used in the NDA instrumentation.

  16. Contribution of the modulation of intensity and the optimization to deliver a dose adapted to the biological heterogeneities; Apport de la modulation d'intensite et de l'optimisation pour delivrer une dose adaptee aux heterogeneites biologiques

    Energy Technology Data Exchange (ETDEWEB)

    Kubs, F

    2007-10-15

    The recent progress in functional imaging by Positron Emission Tomography (TEP) opens new perspectives in the delineation of target volumes in radiotherapy. The functional data is major; we can intend to adapt the irradiation doses on the tumor activity (TA) and to perform a dose escalation. Our objectives were (i) to characterize the TEP threshold, by quantifying the uncertainties of the target volume contour according to the lesion size and the threshold contour level, (ii) to set up the geometry suited to perform a high-precision irradiation based on the TA, (iii) to estimate the dosimetric impact of this new protocol and (iv) to verify that dosimetry is perfectly distributed. Three original phantoms were specially created to satisfy the constraints met, as well as two virtual phantoms containing 3 dose levels (dose level 3 = TA). Our results showed the importance of the effect threshold-volume on the planning in radiotherapy. To use this irradiation method, the diameter of 1 cm for the third level was able to be reached. A dose escalation of 20 Gy was possible between the second (70 Gy) and the third level (90 Gy). The dosimetric impact estimated on two real cases was suitable - increase of COIN (conformal index) from 0.6 to 0.8 and decrease of NTCP (normal tissue complication probability) of a factor 5 -. In absolute and relative dosimetry, the clinical tolerances were respected. So all the treatment process, going from the diagnosis with the TEP to reveal the TA, to the patient treatment made beforehand on phantom, and going through the ballistic and the dose calculation, was estimated and validated according to our objective to adapt the irradiation to the biological heterogeneities. However such high doses should be carefully estimated before being prescribed clinically and progress is also expected in imaging, because the minimal size which we can irradiate is on the limit of the resolution TEP. (author)

  17. A Hybrid-Streaming Method for Cloud Gaming: To Improve the Graphics Quality delivered on Highly Accessible Game Contents

    Directory of Open Access Journals (Sweden)

    Kar Long Chan

    2017-06-01

    Full Text Available The emerging Cloud Gaming Service provides a highly accessible video gaming experience. With Cloud Gaming, potential players without enough local resource can access high-quality gaming using low-spec devices. With advancing technology, we consider that if the processing power at low-spec devices can be well harvested, the quality delivered on Cloud Gaming can be further improved. Therefore, we propose a Hybrid-Streaming System that aimed at improving the graphic quality delivered by Cloud Gaming. By utilizing the available rendering power from both the Cloud Server and client PC, the system distributes rendering operations to both sides to achieve the desired improvement. Quantitative results show the proposed method improves graphics quality, as well as reducing the server’s workload while attaining acceptable network bandwidth consumption levels.

  18. High-Dose-Rate Monotherapy: Safe and Effective Brachytherapy for Patients With Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Demanes, D. Jeffrey, E-mail: jdemanes@mednet.ucla.edu [California Endocurietherapy at UCLA, Department of Radiation Oncology, David Geffen School of Medicine of University of California at Los Angeles, Los Angeles, CA (United States); Martinez, Alvaro A.; Ghilezan, Michel [William Beaumont Hospital, Royal Oak, MI (United States); Hill, Dennis R.; Schour, Lionel; Brandt, David [California Endocurietherapy, Oakland, CA (United States); Gustafson, Gary [William Beaumont Hospital, Royal Oak, MI (United States)

    2011-12-01

    Purpose: High-dose-rate (HDR) brachytherapy used as the only treatment (monotherapy) for early prostate cancer is consistent with current concepts in prostate radiobiology, and the dose is reliably delivered in a prospectively defined anatomic distribution that meets all the requirements for safe and effective therapy. We report the disease control and toxicity of HDR monotherapy from California Endocurietherapy (CET) and William Beaumont Hospital (WBH) in low- and intermediate-risk prostate cancer patients. Methods and Materials: There were 298 patients with localized prostate cancer treated with HDR monotherapy between 1996 and 2005. Two biologically equivalent hypofractionation protocols were used. At CET the dose was 42 Gy in six fractions (two implantations 1 week apart) delivered to a computed tomography-defined planning treatment volume. At WBH the dose was 38 Gy in four fractions (one implantation) based on intraoperative transrectal ultrasound real-time treatment planning. The bladder, urethral, and rectal dose constraints were similar. Toxicity was scored with the National Cancer Institute Common Toxicity Criteria for Adverse Events version 3. Results: The median follow-up time was 5.2 years. The median age of the patients was 63 years, and the median value of the pretreatment prostate-specific antigen was 6.0 ng/mL. The 8-year results were 99% local control, 97% biochemical control (nadir +2), 99% distant metastasis-free survival, 99% cause-specific survival, and 95% overall survival. Toxicity was scored per event, meaning that an individual patient with more than one symptom was represented repeatedly in the morbidity data table. Genitourinary toxicity consisted of 10% transient Grade 2 urinary frequency or urgency and 3% Grade 3 episode of urinary retention. Gastrointestinal toxicity was <1%. Conclusions: High disease control rates and low morbidity demonstrate that HDR monotherapy is safe and effective for patients with localized prostate cancer.

  19. Low or High Fractionation Dose {beta}-Radiotherapy for Pterygium? A Randomized Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Viani, Gustavo Arruda, E-mail: gusviani@gmail.com [Department of Radiation Oncology, Marilia Medicine School, Sao Paulo, SP (Brazil); De Fendi, Ligia Issa; Fonseca, Ellen Carrara [Department of Ophthalmology, Marilia Medicine School, Sao Paulo, SP (Brazil); Stefano, Eduardo Jose [Department of Radiation Oncology, Marilia Medicine School, Sao Paulo, SP (Brazil)

    2012-02-01

    Purpose: Postoperative adjuvant treatment using {beta}-radiotherapy (RT) is a proven technique for reducing the recurrence of pterygium. A randomized trial was conducted to determine whether a low fractionation dose of 2 Gy within 10 fractions would provide local control similar to that after a high fractionation dose of 5 Gy within 7 fractions for surgically resected pterygium. Methods: A randomized trial was conducted in 200 patients (216 pterygia) between February 2006 and July 2007. Only patients with fresh pterygium resected using a bare sclera method and given RT within 3 days were included. Postoperative RT was delivered using a strontium-90 eye applicator. The pterygia were randomly treated using either 5 Gy within 7 fractions (Group 1) or 2 Gy within 10 fractions (Group 2). The local control rate was calculated from the date of surgery. Results: Of the 216 pterygia included, 112 were allocated to Group 1 and 104 to Group 2. The 3-year local control rate for Groups 1 and 2 was 93.8% and 92.3%, respectively (p = .616). A statistically significant difference for cosmetic effect (p = .034), photophobia (p = .02), irritation (p = .001), and scleromalacia (p = .017) was noted in favor of Group 2. Conclusions: No better local control rate for postoperative pterygium was obtained using high-dose fractionation vs. low-dose fractionation. However, a low-dose fractionation schedule produced better cosmetic effects and resulted in fewer symptoms than high-dose fractionation. Moreover, pterygia can be safely treated in terms of local recurrence using RT schedules with a biologic effective dose of 24-52.5 Gy{sub 10.}.

  20. Calcium carbonate as a possible dosimeter for high irradiation doses

    Energy Technology Data Exchange (ETDEWEB)

    Negron M, A.; Ramos B, S.; Camargo R, C. [UNAM, Instituto de Ciencias Nucleares, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Uribe, R. M. [Kent State University, College of Technology, Kent OH (United States); Gomez V, V. [UNAM, Instituto de Quimica, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Kobayashi, K., E-mail: negron@nucleares.unam.mx [Yokohama National University (Japan)

    2014-08-15

    The aim of this work is to analyze the interactions of 5 MeV electron beam radiation and a 290 MeV/u Carbon beam with calcium carbonate (powder) at 298 K and at different irradiation doses, for the potential use of calcium carbonate as a high-dose dosimeter. The irradiation doses with the electron beam were from 0.015 to 9 MGy, and with Carbon beam from 1.5 kGy to 8 kGy. High-energy radiation induces the formation of free radicals in solid calcium carbonate that can be detected and measured by electron paramagnetic resonance (EPR). An increase of the EPR response for some of the free radicals produced in the sample was observed as a function of the irradiation dose. The response of one of the radicals decreased with the dose. These measurements are reproducible; the preparation of the sample is simple and inexpensive; and the signal is stable for several months. The response curves show that the dosimeter tends to saturate at 10 MGy. Based on these properties, we propose this chemical compound as a high-dose dosimeter, mainly for electron irradiation. (author)

  1. High dose rate interstitial brachytherapy in soft tissue sarcomas: technical aspect

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Mi Son; Kang, Seung Hee; Kim, Byoung Suck; Oh, Young Taek [College of Medicine, Ajou Univ., Suwon (Korea, Republic of)

    1999-03-01

    To discuss the technical aspect of interstitial brachytherapy including method of implant, insertion time of radioactive source, total radiation dose, and complication, we reviewed patients who had diagnoses of soft tissue sarcoma and were treated by conservative surgery, interstitial implant and external beam radiation therapy. Between May 1995 and Dec. 1997, the patients with primary or recurrent soft tissue sarcoma underwent surgical resection (wide margin excision) and received radiotherapy including interstitial brachytherapy. Catheters were placed with regular intervals of 1-1.5 cm immediately after tumor removal and covering the critical structures, such as neurovascular bundle or bone, with gelform, muscle, or tissue expander in the cases where the tumors were close to those structures. Brachytherapy consisted of source axis with 2-2.5 Gy/fraction, twice a day, starting on 6th day after the surgery. Within one month after the surgery, total dose of 50-55 Gy was delivered to the tumor bed with wide margin by the external beam radiotherapy. All patients completed planned interstitial brachytherapy without acute side effects directly related with catheter implantation such as infection or bleeding. With median follow up duration of 25 months (range 12-41 months), no local recurrences were observed. And there was no severe form of chromic complication (RTOG/EORTC grade 3 or 4). The high dose rate interstitial brachytherapy is easy and safe way to minimize the radiation dose delivered to the adjacent normal tissue and to decrease radiation induced chronic morbidity such as fibrosis by reducing the total dose of external radiotherapy in the management of soft tissue sarcoma with conservative surgery.

  2. Cálculo independente de dose para tratamentos de arco dinâmico com colimador micromultilâminas Independent dose calculation for dynamic arc treatments delivered with micromultileaf collimator

    Directory of Open Access Journals (Sweden)

    Juan Fernando Delgado

    2006-10-01

    colimador micromultilâminas, nos quais um cálculo manual é muito difícil ou inviável, pela complexidade da técnica.OBJECTIVE: In treatment techniques such as dynamic arc, the manual verification of treatment planning system calculations is very difficult. In these cases, the use of computational tools is useful and becomes an essential component of the quality assurance program. MATERIALS AND METHODS: A worksheet-based software has been created to perform an independent dose or monitor unit calculation in treatments applying the dynamic arc technique delivered with micromultileaf collimator. The dose values calculated per arc and per complete treatment, are compared with values obtained from BrainScan v5.3 treatment planning system. The software has been tested with 229 dynamic arc fields representing 42 skull treatments. From these 229 fields, 109 have been calculated in 3D reconstruction of patients CT images, 109 in reconstruction of polymethylmetacrylate phantom images, and 21 in reconstruction of images from a water equivalent phantom. RESULTS: The mean difference of total doses found in the 42 treatments (composites of one or more dynamic arcs, between the verification software and the treatment planning system, was of +1.73% with a 0.76% standard deviation. The maximum difference was 3.32% and the minimum -0.20%. When the 229 dynamic arcs were tested one by one, the average difference found was 1.61% with a 1.04% standard deviation. Maximum and minimum differences were, respectively 4.01% and -2.04%. As a result of the test, in 80.35% the doses calculated have presented a ± 2.5% difference in relation to the doses generated by the planning system. CONCLUSION: The software presented in this study is recommended for checking point dose included in treatment plans as an integral part of the process of quality assurance in radiotherapy and stereotactic radiosurgery when the dynamic arc technique is utilized in treatment with micromultileaf collimator, where a

  3. Radionuclide characterization and associated dose from long-lived radionuclides in close-in fallout delivered to the marine environment at Bikini and Enewetak Atoll

    Energy Technology Data Exchange (ETDEWEB)

    Noshkin, V. E.; Robison, W. L.

    1998-09-01

    Between June 1946 and October 1958, Enewetak and Bikini Atolls were used by the United States as testing grounds for 66 nuclear devices. The combined explosive yield from these tests was 107 Mt (Mt TNT equivalents). This testing produced close-in fallout debris that was contaminated with quantities of radioactive fission and particle activated products, and unspent radioactive nuclear fuel that entered the aquatic environment of the atolls. Today, the sediments in the lagoons are reservoirs for 10's of TBq of the transuranics and some long-lived fission and activation products. The larger amounts of contamination are associated with fine and coarse sediment material adjacent to the locations of the high yield explosions. Radionuclides are also distributed vertically in the sediment column to various depths in all regions of the lagoons. Concentrations greater than fallout background levels are found in filtered water sampled over several decades from all locations and depths in the lagoons. This is a direct indication that the radionuclides are continuously mobilized to solution from the solid phases. Of particular importance is the fact that the long-lived radionuclides are accumulated to different levels by indigenous aquatic plants and organisms that are used as food by resident people. One might anticipate finding continuous high contamination levels in many of the edible marine organisms from the lagoons, since the radionuclides associated with the sediments are not contained and are available to the different organisms in a relatively shallow water environment. This is not the case. We estimate that the radiological dose from consumption of the edible parts of marine foods at Enewetak and Bikini is presently about 0.05% of the total 50-year integral effective dose from all other exposure pathways that include ingestion of terrestrial foods and drinking water, external exposure and inhalation. The total radiological dose from the marine pathway is

  4. Radionuclide characterization and associated dose from long-lived radionuclides in close-in fallout delivered to the marine environment at Bikini and Enewetak Atoll

    Energy Technology Data Exchange (ETDEWEB)

    Noshkin, V. E.; Robison, W. L.

    1998-09-01

    Between June 1946 and October 1958, Enewetak and Bikini Atolls were used by the United States as testing grounds for 66 nuclear devices. The combined explosive yield from these tests was 107 Mt (Mt TNT equivalents). This testing produced close-in fallout debris that was contaminated with quantities of radioactive fission and particle activated products, and unspent radioactive nuclear fuel that entered the aquatic environment of the atolls. Today, the sediments in the lagoons are reservoirs for 10's of TBq of the transuranics and some long-lived fission and activation products. The larger amounts of contamination are associated with fine and coarse sediment material adjacent to the locations of the high yield explosions. Radionuclides are also distributed vertically in the sediment column to various depths in all regions of the lagoons. Concentrations greater than fallout background levels are found in filtered water sampled over several decades from all locations and depths in the lagoons. This is a direct indication that the radionuclides are continuously mobilized to solution from the solid phases. Of particular importance is the fact that the long-lived radionuclides are accumulated to different levels by indigenous aquatic plants and organisms that are used as food by resident people. One might anticipate finding continuous high contamination levels in many of the edible marine organisms from the lagoons, since the radionuclides associated with the sediments are not contained and are available to the different organisms in a relatively shallow water environment. This is not the case. We estimate that the radiological dose from consumption of the edible parts of marine foods at Enewetak and Bikini is presently about 0.05% of the total 50-year integral effective dose from all other exposure pathways that include ingestion of terrestrial foods and drinking water, external exposure and inhalation. The total radiological dose from the marine pathway is

  5. Spectroscopic gamma camera for use in high dose environments

    Science.gov (United States)

    Ueno, Yuichiro; Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi; Fujishima, Yasutake; Kometani, Yutaka; Suzuki, Yasuhiko; Umegaki, Kikuo

    2016-06-01

    We developed a pinhole gamma camera to measure distributions of radioactive material contaminants and to identify radionuclides in extraordinarily high dose regions (1000 mSv/h). The developed gamma camera is characterized by: (1) tolerance for high dose rate environments; (2) high spatial and spectral resolution for identifying unknown contaminating sources; and (3) good usability for being carried on a robot and remotely controlled. These are achieved by using a compact pixelated detector module with CdTe semiconductors, efficient shielding, and a fine resolution pinhole collimator. The gamma camera weighs less than 100 kg, and its field of view is an 8 m square in the case of a distance of 10 m and its image is divided into 256 (16×16) pixels. From the laboratory test, we found the energy resolution at the 662 keV photopeak was 2.3% FWHM, which is enough to identify the radionuclides. We found that the count rate per background dose rate was 220 cps h/mSv and the maximum count rate was 300 kcps, so the maximum dose rate of the environment where the gamma camera can be operated was calculated as 1400 mSv/h. We investigated the reactor building of Unit 1 at the Fukushima Dai-ichi Nuclear Power Plant using the gamma camera and could identify the unknown contaminating source in the dose rate environment that was as high as 659 mSv/h.

  6. Spectroscopic gamma camera for use in high dose environments

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Yuichiro, E-mail: yuichiro.ueno.bv@hitachi.com [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Takahashi, Isao; Ishitsu, Takafumi; Tadokoro, Takahiro; Okada, Koichi; Nagumo, Yasushi [Research and Development Group, Hitachi, Ltd., Hitachi-shi, Ibaraki-ken 319-1221 (Japan); Fujishima, Yasutake; Kometani, Yutaka [Hitachi Works, Hitachi-GE Nuclear Energy, Ltd., Hitachi-shi, Ibaraki-ken (Japan); Suzuki, Yasuhiko [Measuring Systems Engineering Dept., Hitachi Aloka Medical, Ltd., Ome-shi, Tokyo (Japan); Umegaki, Kikuo [Faculty of Engineering, Hokkaido University, Sapporo-shi, Hokkaido (Japan)

    2016-06-21

    We developed a pinhole gamma camera to measure distributions of radioactive material contaminants and to identify radionuclides in extraordinarily high dose regions (1000 mSv/h). The developed gamma camera is characterized by: (1) tolerance for high dose rate environments; (2) high spatial and spectral resolution for identifying unknown contaminating sources; and (3) good usability for being carried on a robot and remotely controlled. These are achieved by using a compact pixelated detector module with CdTe semiconductors, efficient shielding, and a fine resolution pinhole collimator. The gamma camera weighs less than 100 kg, and its field of view is an 8 m square in the case of a distance of 10 m and its image is divided into 256 (16×16) pixels. From the laboratory test, we found the energy resolution at the 662 keV photopeak was 2.3% FWHM, which is enough to identify the radionuclides. We found that the count rate per background dose rate was 220 cps h/mSv and the maximum count rate was 300 kcps, so the maximum dose rate of the environment where the gamma camera can be operated was calculated as 1400 mSv/h. We investigated the reactor building of Unit 1 at the Fukushima Dai-ichi Nuclear Power Plant using the gamma camera and could identify the unknown contaminating source in the dose rate environment that was as high as 659 mSv/h.

  7. Brachytherapy optimization using radiobiological-based planning for high dose rate and permanent implants for prostate cancer treatment

    Science.gov (United States)

    Seeley, Kaelyn; Cunha, J. Adam; Hong, Tae Min

    2017-01-01

    We discuss an improvement in brachytherapy--a prostate cancer treatment method that directly places radioactive seeds inside target cancerous regions--by optimizing the current standard for delivering dose. Currently, the seeds' spatiotemporal placement is determined by optimizing the dose based on a set of physical, user-defined constraints. One particular approach is the ``inverse planning'' algorithms that allow for tightly fit isodose lines around the target volumes in order to reduce dose to the patient's organs at risk. However, these dose distributions are typically computed assuming the same biological response to radiation for different types of tissues. In our work, we consider radiobiological parameters to account for the differences in the individual sensitivities and responses to radiation for tissues surrounding the target. Among the benefits are a more accurate toxicity rate and more coverage to target regions for planning high-dose-rate treatments as well as permanent implants.

  8. Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations

    Energy Technology Data Exchange (ETDEWEB)

    Granero, Domingo, E-mail: dgranero@eresa.com [Department of Radiation Physics, ERESA, Hospital General Universitario, 46014 Valencia (Spain); Perez-Calatayud, Jose [Radiotherapy Department, La Fe University and Polytechnic Hospital, Valencia 46026 (Spain); Vijande, Javier [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100, Spain and IFIC (UV-CSIC), Paterna 46980 (Spain); Ballester, Facundo [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States)

    2014-02-15

    Purpose: In skin high-dose-rate (HDR) brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Most treatment planning systems use the TG-43 formalism, which is based on single-source dose superposition within an infinite water medium without accounting for the true geometry in which conditions for scattered radiation are altered by the presence of air. The purpose of this study is to evaluate the dosimetric limitations of the TG-43 formalism in HDR skin brachytherapy and the potential clinical impact. Methods: Dose rate distributions of typical configurations used in skin brachytherapy were obtained: a 5 cm × 5 cm superficial mould; a source inside a catheter located at the skin surface with and without backscatter bolus; and a typical interstitial implant consisting of an HDR source in a catheter located at a depth of 0.5 cm. Commercially available HDR{sup 60}Co and {sup 192}Ir sources and a hypothetical {sup 169}Yb source were considered. The Geant4 Monte Carlo radiation transport code was used to estimate dose rate distributions for the configurations considered. These results were then compared to those obtained with the TG-43 dose calculation formalism. In particular, the influence of adding bolus material over the implant was studied. Results: For a 5 cm × 5 cm{sup 192}Ir superficial mould and 0.5 cm prescription depth, dose differences in comparison to the TG-43 method were about −3%. When the source was positioned at the skin surface, dose differences were smaller than −1% for {sup 60}Co and {sup 192}Ir, yet −3% for {sup 169}Yb. For the interstitial implant, dose differences at the skin surface were −7% for {sup 60}Co, −0.6% for {sup 192}Ir, and −2.5% for {sup 169}Yb. Conclusions: This study indicates the following: (i) for the superficial mould, no bolus is needed; (ii) when the source is in contact with the skin surface, no bolus is needed for either {sup 60}Co and {sup 192}Ir. For

  9. Monte Carlo study of radiation dose enhancement by gadolinium in megavoltage and high dose rate radiotherapy.

    Directory of Open Access Journals (Sweden)

    Daniel G Zhang

    Full Text Available MRI is often used in tumor localization for radiotherapy treatment planning, with gadolinium (Gd-containing materials often introduced as a contrast agent. Motexafin gadolinium is a novel radiosensitizer currently being studied in clinical trials. The nanoparticle technologies can target tumors with high concentration of high-Z materials. This Monte Carlo study is the first detailed quantitative investigation of high-Z material Gd-induced dose enhancement in megavoltage external beam photon therapy. BEAMnrc, a radiotherapy Monte Carlo simulation package, was used to calculate dose enhancement as a function of Gd concentration. Published phase space files for the TrueBeam flattening filter free (FFF and conventional flattened 6MV photon beams were used. High dose rate (HDR brachytherapy with Ir-192 source was also investigated as a reference. The energy spectra difference caused a dose enhancement difference between the two beams. Since the Ir-192 photons have lower energy yet, the photoelectric effect in the presence of Gd leads to even higher dose enhancement in HDR. At depth of 1.8 cm, the percent mean dose enhancement for the FFF beam was 0.38±0.12, 1.39±0.21, 2.51±0.34, 3.59±0.26, and 4.59±0.34 for Gd concentrations of 1, 5, 10, 15, and 20 mg/mL, respectively. The corresponding values for the flattened beam were 0.09±0.14, 0.50±0.28, 1.19±0.29, 1.68±0.39, and 2.34±0.24. For Ir-192 with direct contact, the enhanced were 0.50±0.14, 2.79±0.17, 5.49±0.12, 8.19±0.14, and 10.80±0.13. Gd-containing materials used in MRI as contrast agents can also potentially serve as radiosensitizers in radiotherapy. This study demonstrates that Gd can be used to enhance radiation dose in target volumes not only in HDR brachytherapy, but also in 6 MV FFF external beam radiotherapy, but higher than the currently used clinical concentration (>5 mg/mL would be needed.

  10. Monte Carlo study of radiation dose enhancement by gadolinium in megavoltage and high dose rate radiotherapy.

    Science.gov (United States)

    Zhang, Daniel G; Feygelman, Vladimir; Moros, Eduardo G; Latifi, Kujtim; Zhang, Geoffrey G

    2014-01-01

    MRI is often used in tumor localization for radiotherapy treatment planning, with gadolinium (Gd)-containing materials often introduced as a contrast agent. Motexafin gadolinium is a novel radiosensitizer currently being studied in clinical trials. The nanoparticle technologies can target tumors with high concentration of high-Z materials. This Monte Carlo study is the first detailed quantitative investigation of high-Z material Gd-induced dose enhancement in megavoltage external beam photon therapy. BEAMnrc, a radiotherapy Monte Carlo simulation package, was used to calculate dose enhancement as a function of Gd concentration. Published phase space files for the TrueBeam flattening filter free (FFF) and conventional flattened 6MV photon beams were used. High dose rate (HDR) brachytherapy with Ir-192 source was also investigated as a reference. The energy spectra difference caused a dose enhancement difference between the two beams. Since the Ir-192 photons have lower energy yet, the photoelectric effect in the presence of Gd leads to even higher dose enhancement in HDR. At depth of 1.8 cm, the percent mean dose enhancement for the FFF beam was 0.38±0.12, 1.39±0.21, 2.51±0.34, 3.59±0.26, and 4.59±0.34 for Gd concentrations of 1, 5, 10, 15, and 20 mg/mL, respectively. The corresponding values for the flattened beam were 0.09±0.14, 0.50±0.28, 1.19±0.29, 1.68±0.39, and 2.34±0.24. For Ir-192 with direct contact, the enhanced were 0.50±0.14, 2.79±0.17, 5.49±0.12, 8.19±0.14, and 10.80±0.13. Gd-containing materials used in MRI as contrast agents can also potentially serve as radiosensitizers in radiotherapy. This study demonstrates that Gd can be used to enhance radiation dose in target volumes not only in HDR brachytherapy, but also in 6 MV FFF external beam radiotherapy, but higher than the currently used clinical concentration (>5 mg/mL) would be needed.

  11. Remote Afterloading High Dose Rate Brachytherapy AMC EXPERIANCES

    Energy Technology Data Exchange (ETDEWEB)

    Park, Su Gyong; Chang, Hye Sook; Choi, Eun Kyong; Yi, Byong Yong [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    1992-12-15

    Remote afterloading high dose rate brachytherapy(HDRB) is a new technology and needs new biological principle for time and dose schedule. Here, authors attempt to evaluate the technique and clinical outcome in 116 patients, 590 procedures performed at Asan Medical Center for 3 years. From Sep. 1985 to Aug 1992, 471 procedures of intracavitary radiation in 55 patients of cervical cancer and 26 of nasopharyngeal cancer, 79 intraluminal radiation in 12 of esophageal cancer, 11 of endobronchial cancer and 1 Klatskin tumor and 40 interstitial brachytherapy in 4 of breast cancer, 1 sarcoma and 1 urethral cancer were performed. Median follow-up was 7 months with range 1-31 months. All procedures except interstitial were performed under the local anesthesia and they were all well tolerated and completed the planned therapy except 6 patients. 53/58 patients with cervical cancer and 22/26 patients with nasopharynx cancer achieved CR. Among 15 patients with palliative therapy, 80% achieves palliation. We will describe the details of the technique and results in the text. To evaluate biologic effects of HDRB and optimal time/dose/fractionation schedule, we need longer follow-up. But authors feel that HDRB with proper fractionation schedule may yield superior results compared to the low dose rate brachytherapy considering the advantages of HDRB in safety factor for operator, better control of radiation dose and volume and patients comfort over the low dose brachytherapy.

  12. Delivering high-quality family planning services in crisis-affected settings I: program implementation.

    Science.gov (United States)

    Curry, Dora Ward; Rattan, Jesse; Nzau, Jean Jose; Giri, Kamlesh

    2015-02-04

    In 2012, about 43 million women of reproductive age experienced the effects of conflict. Provision of basic sexual and reproductive health services, including family planning, is a recognized right and need of refugees and internally displaced people, but funding and services for family planning have been inadequate. This article describes lessons learned during the first 2.5 years of implementing the ongoing Supporting Access to Family Planning and Post-Abortion Care in Emergencies (SAFPAC) initiative, led by CARE, which supports government health systems to deliver family planning services in 5 crisis-affected settings (Chad, Democratic Republic of the Congo, Djibouti, Mali, and Pakistan). SAFPAC's strategy focuses on 4 broad interventions drawn from public health best practices in more stable settings: competency-based training for providers, improved supply chain management, regular supervision, and community mobilization to influence attitudes and norms related to family planning. Between July 2011 and December 2013, the initiative reached 52,616 new users of modern contraceptive methods across the 5 countries (catchment population of 698,053 women of reproductive age), 61% of whom chose long-acting methods of implants or intrauterine devices. Prudent use of data to inform decision making has been an underpinning to the project's approach. A key approach to ensuring sustained ability to train and supervise new providers has been to build capacity in clinical skills training and supervision by establishing in-country training centers. In addition, monthly supervision using simple checklists has improved program and service quality, particularly with infection prevention procedures and stock management. We have generally instituted a "pull" system to manage commodities and other supplies, whereby health facilities place resupply orders as needed based on actual consumption patterns and stock-alert thresholds. Finally, reaching the community with mobilization

  13. Delivering high-quality family planning services in crisis-affected settings II: results.

    Science.gov (United States)

    Curry, Dora Ward; Rattan, Jesse; Huang, Shuyuan; Noznesky, Elizabeth

    2015-02-04

    An estimated 43 million women of reproductive age experienced the effects of conflict in 2012. Already vulnerable from the insecurity of the emergency, women must also face the continuing risk of unwanted pregnancy but often are unable to obtain family planning services. The ongoing Supporting Access to Family Planning and Post-Abortion Care (SAFPAC) initiative, led by CARE, has provided contraceptives, including long-acting reversible contraceptives (LARCs), to refugees, internally displaced persons, and conflict-affected resident populations in Chad, the Democratic Republic of the Congo (DRC), Djibouti, Mali, and Pakistan. The project works through the Ministry of Health in 4 key areas: (1) competency-based training, (2) supply chain management, (3) systematic supervision, and (4) community mobilization to raise awareness and shift norms related to family planning. This article presents data on program results from July 2011 to December 2013 from the 5 countries. Project staff summarized monthly data from client registers using hard-copy forms and recorded the data electronically in Microsoft Excel for compilation and analysis. The initiative reached 52,616 new users of modern contraceptive methods across the 5 countries, ranging from 575 in Djibouti to 21,191 in Chad. LARCs have predominated overall, representing 61% of new modern method users. The percentage of new users choosing LARCs varied by country: 78% in the DRC, 72% in Chad, and 51% in Mali, but only 29% in Pakistan. In Djibouti, those methods were not offered in the country through SAFPAC during the period discussed here. In Chad, the DRC, and Mali, implants have been the most popular LARC method, while in Pakistan the IUD has been more popular. Use of IUDs, however, has comprised a larger share of the method mix over time in all 4 of these countries. These results to date suggest that it is feasible to work with the public sector in fragile, crisis-affected states to deliver a wide range of quality

  14. Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Y. Sobita Devi

    2011-12-01

    Full Text Available Purpose: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation withlocal/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate(HDR brachytherapy (BT source is reduced to single, double and triple half life in relation to original strength of10 Ci (~ 4.081 cGy x m2 x h–1. Material and methods: A retrospective study was carried out on 52 cervical cancer patients with stage II and IIItreated with fractionated HDR-BT following external beam radiation therapy (EBRT. International Commission onRadiation Units and Measurement (ICRU points were defined according to ICRU Report 38, using two orthogonal radiographimages taken by Simulator (Simulix HQ. Biologically effective dose (BED was calculated at point A for diffe -rent Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. Result: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervicalcancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction ofsource strength, respectively. The probabilities of disease recurrence (local/loco-regional within 26 months are expectedas 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m2 x h–1, respectively.The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. Conclusions: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 sourcestrength shows reduction in disease free survival according to the increase in treatment time duration per fraction.The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical

  15. CORRELATION OF LOCAL FAILURE WITH MEASURES OF DOSE INSUFFICIENCY IN THE HIGH-DOSE SINGLE-FRACTION TREATMENT OF BONY METASTASES

    Science.gov (United States)

    Lovelock, D. Michael; Zhang, Zhigang; Jackson, Andrew; Keam, Jennifer; Bekelman, Justin; Bilsky, Mark; Lis, Eric; Yamada, Yoshiya

    2011-01-01

    Purpose In the setting of high-dose single-fraction image-guided radiotherapy of spine metastases, the delivered dose is hypothesized to be a significant factor in local control. We investigated the dependence of local control on measures of dose insufficiency. Methods and Materials The minimum doses received by the hottest 100%, 98%, and 95% (Dmin, D98, and D95) of the gross target volume (GTV) were computed for 91 consecutively treated lesions observed in 79 patients. Prescribed doses of 18–24 Gy were delivered in a single fraction. The spinal cord and cauda equina were constrained to a maximum dose of 12–14 Gy and 16 Gy, respectively. A rank-sum test was used to assess the differences between radiographic local failure and local control. Results With a median follow-up of 18 months, seven local failures have occurred. The distributions of GTV Dmin, D98, and D95 for treatments resulting in local failure were found to be statistically different from the corresponding distributions of the patient group as a whole. Taking no account of histology, p values calculated for Dmin, D98, and D95 were 0.004, 0.012, and 0.031, respectively. No correlations between local failure and target volume or between local failure and anatomic location were found. Conclusions The results indicate that Dmin, D98, and D95 may be important risk factors for local failure. No local failures in any histology were observed when Dmin was >15 Gy, suggesting that this metric may be an important predictor of local control. PMID:20350795

  16. High-dose Helical Tomotherapy With Concurrent Full-dose Chemotherapy for Locally Advanced Pancreatic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Jee Suk [Department of Radiation Oncology, Yonsei University College of Medicine, Seoul (Korea, Republic of); Wang, Michael L.C. [Department of Radiation Oncology, National Cancer Centre (Singapore); Koom, Woong Sub; Yoon, Hong In; Chung, Yoonsun [Department of Radiation Oncology, Yonsei University College of Medicine, Seoul (Korea, Republic of); Song, Si Young [Department of Internal Medicine, Yonsei University College of Medicine, Seoul (Korea, Republic of); Seong, Jinsil, E-mail: jsseong@yuhs.ac [Department of Radiation Oncology, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2012-08-01

    Purpose: To improve poor therapeutic outcome of current practice of chemoradiotherapy (CRT), high-dose helical tomotherapy (HT) with concurrent full-dose chemotherapy has been performed on patients with locally advanced pancreatic cancer (LAPC), and the results were analyzed. Methods and Materials: We retrospectively reviewed 39 patients with LAPC treated with radiotherapy using HT (median, 58.4 Gy; range, 50.8-59.9 Gy) and concomitant chemotherapy between 2006 and 2009. Radiotherapy was directed to the primary tumor with a 0.5-cm margin without prophylactic nodal coverage. Twenty-nine patients (79%) received full-dose (1000 mg/m{sup 2}) gemcitabine-based chemotherapy during HT. After completion of CRT, maintenance chemotherapy was administered to 37 patients (95%). Results: The median follow-up was 15.5 months (range, 3.4-43.9) for the entire cohort, and 22.5 months (range, 12.0-43.9) for the surviving patients. The 1- and 2-year local progression-free survival rates were 82.1% and 77.3%, respectively. Eight patients (21%) were converted to resectable status, including 1 with a pathological complete response. The median overall survival and progression-free survival were 21.2 and 14.0 months, respectively. Acute toxicities were acceptable with no gastrointestinal (GI) toxicity higher than Grade 3. Severe late GI toxicity ({>=}Grade 3) occurred in 10 patients (26%); 1 treatment-related death from GI bleeding was observed. Conclusion: High-dose helical tomotherapy with concurrent full-dose chemotherapy resulted in improved local control and long-term survival in patients with LAPC. Future studies are needed to widen the therapeutic window by minimizing late GI toxicity.

  17. The influence of high doses of radiation in citrine stones

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, M. I. [Universidade Nove de Julho - UNINOVE, Rua Vergueiro 235/249, 01504-001 Sao Paulo (Brazil); Caldas, L. V. E., E-mail: miteixeira@ipen.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The possibility of using samples of Brazilian stones as quartz, amethyst, topaz, jasper, etc. for high-dose dosimetry has been studied in recent years at IPEN, using the techniques of optical absorption (Oa), thermoluminescent (Tl), optically stimulated luminescence (OSL) and resonance paramagnetic electron (EPR). In this work, the Tl properties of citrine samples were studied. They were exposed to different doses of gamma radiation ({sup 60}Co). The natural citrine stone was extracted from a mine in Minas Gerais state, Brazil; it is a tecto silicate ranked as one of three-dimensional structure, showing clear yellow to golden brown color. The natural citrine stone is classified as quartz (SiO{sub 2}), and it has a lower symmetry and more compact reticulum. The Tl emission curve showed two peaks at 160 grades C and 220 grades C. To remove the Tl peak (160 grades C) of the sintered citrine pellet glow curves, different thermal treatments were tested during several time intervals. The Tl dose-response curve between 50 Gy and 100 kGy, the reproducibility of Tl response and the lower detection dose were obtained. The results show that citrine may be useful as high-dose detectors. (Author)

  18. Multifocal Electroretinography after High Dose Chloroquine Therapy for Malaria

    Directory of Open Access Journals (Sweden)

    Aline Correa de Carvalho

    2013-01-01

    Full Text Available Purpose: To investigate changes in multifocal electroretinography (mfERG parameters associated with high dose chloroquine therapy for treatment of malaria in the Amazonia region of Brazil. Methods: Forty-eight subjects who had received chloroquine treatment for single or multiple malaria infections with a cumulative dose ranging from 1,050 to 27,000mg were included. The control group consisted of 37 healthy aged-matched subjects. Data was collected on amplitude and implicit time of the N1, P1 and N2 waves in the central macular hexagon (R1 and in five concentric rings at different retinal eccentricities (R2-R6. Results: No significant difference was observed in any mfERG parameter between chloroquine treated patients and control subjects. A comparison with previous data obtained from patients with rheumatologic disorders in the same region of Brazil who had received larger cumulative doses of chloroquine and had displayed mfERG changes, indicated that retinal toxicity seems to be dependent on cumulative dose. Conclusion: Lack of mfERG changes in the current study suggests that intensive high dose chloroquine therapy for treatment of malaria is not associated with retinal toxicity.

  19. Membrane Signaling Induced by High Doses of Ionizing Radiation in the Endothelial Compartment. Relevance in Radiation Toxicity

    Directory of Open Access Journals (Sweden)

    Isabelle Corre

    2013-11-01

    Full Text Available Tumor areas can now be very precisely delimited thanks to technical progress in imaging and ballistics. This has also led to the development of novel radiotherapy protocols, delivering higher doses of ionizing radiation directly to cancer cells. Despite this, radiation toxicity in healthy tissue remains a major issue, particularly with dose-escalation in these new protocols. Acute and late tissue damage following irradiation have both been linked to the endothelium irrigating normal tissues. The molecular mechanisms involved in the endothelial response to high doses of radiation are associated with signaling from the plasma membrane, mainly via the acid sphingomyelinase/ceramide pathway. This review describes this signaling pathway and discusses the relevance of targeting endothelial signaling to protect healthy tissues from the deleterious effects of high doses of radiation.

  20. High-dose acetylcysteine in idiopathic pulmonary fibrosis.

    NARCIS (Netherlands)

    Demedts, M.; Behr, J.; Buhl, R.; Costabel, U.; Dekhuijzen, P.N.R.; Jansen, H.M.L.; MacNee, W.; Thomeer, M.; Wallaert, B.; Laurent, F.; Nicholson, A.G.; Verbeken, E.K.; Verschakelen, J.; Flower, C.D.; Capron, F.; Petruzzelli, S.; Vuyst, P. De; Bosch, J.M. van den; Rodriguez-Becerra, E.; Corvasce, G.; Lankhorst, I.L.M.; Sardina, M.; Montanari, M.

    2005-01-01

    BACKGROUND: Idiopathic pulmonary fibrosis is a chronic progressive disorder with a poor prognosis. METHODS: We conducted a double-blind, randomized, placebo-controlled multicenter study that assessed the effectiveness over one year of a high oral dose of acetylcysteine (600 mg three times daily) add

  1. Oval pulsed high-dose dexamethasone for myositis

    NARCIS (Netherlands)

    Hoogendijk, JE; Wokke, JHJ; de Visser, M

    2000-01-01

    To study the short-term effect of oral pulsed high-dose dexamethasone for myositis we treated eight newly diagnosed patients with three 28-day cycles of oral dexamethasone. Primary outcome measures were muscle strength, pain, and serum creatine kinase activity. Sis patients responded. Side effects w

  2. Bortezomib or high-dose dexamethasone for relapsed multiple myeloma

    NARCIS (Netherlands)

    P.G. Richardson (Paul Gerard); P. Sonneveld (Pieter); M.W. Schuster (Michael); D. Irwin (David); E.A. Stadtmauer (Edward); T. Facon (Thierry); J-L. Harousseau (Jean-Luc); D. Ben-Yehuda (Dina); S. Lonial (Sagar); H. Goldschmidt (Hartmut); D. Reece (Donna); J.F. San Miguel (Jesús Fernando); J. Bladé (Joan); M. Boccadoro (Mario); J. Cavenagh (Jamie); W. Dalton (William); A.L. Boral (Anthony); D.-L. Esseltine (Dixie-Lee); J.B. Porter (Jane); D. Schenkein (David); K.C. Anderson (Kenneth Carl)

    2005-01-01

    textabstractBACKGROUND: This study compared bortezomib with high-dose dexamethasone in patients with relapsed multiple myeloma who had received one to three previous therapies. METHODS: We randomly assigned 669 patients with relapsed myeloma to receive either an intravenous bolus of bortezomib (1.3

  3. High dose corticosteroids in severe leptospirosis: a systematic review.

    Science.gov (United States)

    Rodrigo, Chaturaka; Lakshitha de Silva, Nipun; Goonaratne, Ravindi; Samarasekara, Keshinie; Wijesinghe, Indika; Parththipan, B; Rajapakse, Senaka

    2014-12-01

    The role of corticosteroids in the treatment of severe leptospirosis is unclear. The rationale for their use is that, in severe leptospirosis, there is a severe immunological response that is harmful to the host resulting in multi-organ dysfunction, which is potentially offset by the nonspecific immunosuppression of high dose steroids. We conducted a systematic review of studies that have assessed the use of high dose corticosteroids in patients with severe leptospirosis by searching MEDLINE and Scopus SciVerse without any language or time restrictions. We identified five studies, including one open randomized clinical trial, which had assessed the use of high dose steroids in severe leptospirosis. Four studies demonstrated a benefit of corticosteroids in treating severe disease with pulmonary involvement when administered early in the course of the disease, but these studies had several methodological constraints as highlighted in the text. Only the randomized controlled trial study showed that corticosteroids are ineffective and may increase the risk of nosocomial infections. There is no robust evidence to suggest that high dose corticosteroids are effective in severe leptospirosis, and a well-designed randomized clinical trial is needed to resolve this.

  4. High-dose acetylcysteine in idiopathic pulmonary fibrosis.

    NARCIS (Netherlands)

    Demedts, M.; Behr, J.; Buhl, R.; Costabel, U.; Dekhuijzen, P.N.R.; Jansen, H.M.L.; MacNee, W.; Thomeer, M.; Wallaert, B.; Laurent, F.; Nicholson, A.G.; Verbeken, E.K.; Verschakelen, J.; Flower, C.D.; Capron, F.; Petruzzelli, S.; Vuyst, P. De; Bosch, J.M. van den; Rodriguez-Becerra, E.; Corvasce, G.; Lankhorst, I.L.M.; Sardina, M.; Montanari, M.

    2005-01-01

    BACKGROUND: Idiopathic pulmonary fibrosis is a chronic progressive disorder with a poor prognosis. METHODS: We conducted a double-blind, randomized, placebo-controlled multicenter study that assessed the effectiveness over one year of a high oral dose of acetylcysteine (600 mg three times daily) add

  5. Bortezomib or high-dose dexamethasone for relapsed multiple myeloma

    NARCIS (Netherlands)

    P.G. Richardson (Paul Gerard); P. Sonneveld (Pieter); M.W. Schuster (Michael); D. Irwin (David); E.A. Stadtmauer (Edward); T. Facon (Thierry); J-L. Harousseau (Jean-Luc); D. Ben-Yehuda (Dina); S. Lonial (Sagar); H. Goldschmidt (Hartmut); D. Reece (Donna); J.F. San Miguel (Jesús Fernando); J. Bladé (Joan); M. Boccadoro (Mario); J. Cavenagh (Jamie); W. Dalton (William); A.L. Boral (Anthony); D.-L. Esseltine (Dixie-Lee); J.B. Porter (Jane); D. Schenkein (David); K.C. Anderson (Kenneth Carl)

    2005-01-01

    textabstractBACKGROUND: This study compared bortezomib with high-dose dexamethasone in patients with relapsed multiple myeloma who had received one to three previous therapies. METHODS: We randomly assigned 669 patients with relapsed myeloma to receive either an intravenous bolus of bortezomib (1.3

  6. High-dose acetylcysteine in idiopathic pulmonary fibrosis.

    NARCIS (Netherlands)

    Demedts, M.; Behr, J.; Buhl, R.; Costabel, U.; Dekhuijzen, P.N.R.; Jansen, H.M.L.; MacNee, W.; Thomeer, M.; Wallaert, B.; Laurent, F.; Nicholson, A.G.; Verbeken, E.K.; Verschakelen, J.; Flower, C.D.; Capron, F.; Petruzzelli, S.; Vuyst, P. De; Bosch, J.M. van den; Rodriguez-Becerra, E.; Corvasce, G.; Lankhorst, I.L.M.; Sardina, M.; Montanari, M.

    2005-01-01

    BACKGROUND: Idiopathic pulmonary fibrosis is a chronic progressive disorder with a poor prognosis. METHODS: We conducted a double-blind, randomized, placebo-controlled multicenter study that assessed the effectiveness over one year of a high oral dose of acetylcysteine (600 mg three times daily)

  7. Brachytherapy for early oral tongue cancer. Low dose rate to high dose rate

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Hideya [Toyonaka Municipal Hospital, Osaka (Japan); Inoue, Takehiro; Yoshida, Ken; Yoshioka, Yasuo; Shimizutani, Kimishige; Inoue, Toshihiko [Osaka Univ., Suita (Japan). Graduate School of Medicine; Furukawa, Souhei; Kakimoto, Naoya [Osaka Univ., Suita (Japan). Graduate School of Dentistry

    2003-03-01

    To examine the compatibility of low dose rate (LDR) with high dose rate (HDR) brachytherapy, we reviewed 399 patients with early oral tongue cancer (T1-2N0M0) treated solely by brachytherapy at Osaka University Hospital between 1967 and 1999. For patients in the LDR group (n=341), the treatment sources consisted of Ir-192 pin for 227 patients (1973-1996; irradiated dose, 61-85 Gy; median, 70 Gy), Ra-226 needle for 113 patients (1967-1986; 55-93 Gy; median, 70 Gy). Ra-226 and Ir-192 were combined for one patient. Ir-192 HDR (microSelectron-HDR) was used for 58 patients in the HDR group (1991-present; 48-60 Gy; median, 60 Gy). LDR implantations were performed via oral and HDR via a submental/submandibular approach. The dose rates at the reference point for the LDR group were 0.30 to 0.8 Gy/h, and for the HDR group 1.0 to 3.4 Gy/min. The patients in the HDR group received a total dose of 48-60 Gy (8-10 fractions) during one week. Two fractions were administered per day (at least a 6-h interval). The 3- and 5-year local control rates for patients in the LDR group were 85% and 80%, respectively, and those in the HDR group were both 84%. HDR brachytherapy showed the same lymph-node control rate as did LDR brachytherapy (67% at 5 years). HDR brachytherapy achieved the same locoregional result as did LDR brachytherapy. A converting factor of 0.86 is applicable for HDR in the treatment of early oral tongue cancer. (author)

  8. Brachytherapy for early oral tongue cancer: low dose rate to high dose rate.

    Science.gov (United States)

    Yamazaki, Hideya; Inoue, Takehiro; Yoshida, Ken; Yoshioka, Yasuo; Furukawa, Souhei; Kakimoto, Naoya; Shimizutani, Kimishige; Inoue, Toshihiko

    2003-03-01

    To examine the compatibility of low dose rate (LDR) with high dose rate (HDR) brachytherapy, we reviewed 399 patients with early oral tongue cancer (T1-2N0M0) treated solely by brachytherapy at Osaka University Hospital between 1967 and 1999. For patients in the LDR group (n = 341), the treatment sources consisted of Ir-192 pin for 227 patients (1973-1996; irradiated dose, 61-85 Gy; median, 70 Gy), Ra-226 needle for 113 patients (1967-1986; 55-93 Gy; median, 70 Gy). Ra-226 and Ir-192 were combined for one patient. Ir-192 HDR (microSelectron-HDR) was used for 58 patients in the HDR group (1991-present; 48-60 Gy; median, 60 Gy). LDR implantations were performed via oral and HDR via a submental/submandibular approach. The dose rates at the reference point for the LDR group were 0.30 to 0.8 Gy/h, and for the HDR group 1.0 to 3.4 Gy/min. The patients in the HDR group received a total dose of 48-60 Gy (8-10 fractions) during one week. Two fractions were administered per day (at least a 6-h interval). The 3- and 5-year local control rates for patients in the LDR group were 85% and 80%, respectively, and those in the HDR group were both 84%. HDR brachytherapy showed the same lymph-node control rate as did LDR brachytherapy (67% at 5 years). HDR brachytherapy achieved the same locoregional result as did LDR brachytherapy. A converting factor of 0.86 is applicable for HDR in the treatment of early oral tongue cancer.

  9. Impairment of memorization by high doses of pyridoxine in man.

    Science.gov (United States)

    Molimard, R; Marillaud, A; Paille, A; Le Devehat, C; Lemoine, A; Dougny, M

    1980-05-01

    Two controlled trials were performed successively to evaluate the effect of high doses of oral pyridoxine on brain performance in man. In trial I, medical students volunteered to take 100 mg, 500 mg of pyridoxine a day or placebo for 10 days. A digit coding test was performed before, and at the end of the treatment period and a third 15 days later. The improvement of performance from the first to the third test (learning effect) was significantly better in the placebo group than in the B6 treated groups. This could be attributed to memorization of skills. Trial II was performed in obese patients starting a low calorie diet in whom vitamins are routinely prescribed. Performance in a work recognition test and in a visual retention test was lower for the group receiving 1 g of pyridoxine a day. Thus, high doses of oral pyridoxine are likely to impair memorization in man. Disturbances of neuro-transmitter metabolism such as increase of GABA production might explain the effect. As the benefit of high doses of pyridoxine has not been well-documented and as the study has suggested that undesired effects may indeed exist, the widespread use of such doses is questionable.

  10. Dose variation due to change in planned position for patients with carcinoma of the cervix undergoing high-dose-rate brachytherapy- 2D dose analysis

    Directory of Open Access Journals (Sweden)

    Anil Talluri

    2015-03-01

    Full Text Available Purpose: To assess the dosimetry to organs at risk (OARs in lithotomy position with a planned time-dose pattern obtained from supine position. Methods: The sample consists of thirty patients with carcinoma of the uterine cervix, Stage II and III. Patients often feel discomfort in supine position (S position when compared to lithotomy position (M position due to relaxation of pelvic floor muscles after the insertion of applicator (tandem and ovoids or before delivery of the treatment. Each patient was imaged with orthogonal X- ray radiographs simultaneously in two positions, i.e. S position and M position. Dwell time and dwell position pattern obtained from the optimized plan in S position was used to generate plan in M position. Following dose reference points (point A, pelvic wall points, bladder points, rectal, anorectum (AR point and rectosigmoid (RS point points were identified for analysis in S and M positions. The dosimetric data for reference points generated by the Brachyvision TPS was analyzed.Results: Pelvic wall points registered lower doses in M position when compared to S position. Mean doses for right pelvic wall point (RPW and left pelvic wall point (LPW were reduced by -10.02 % and -11.5% in M position, respectively. International Commission on Radiation Units and Measurements (ICRU bladder point also registered lower doses in M position with a mean dose of -6.8%. Rectal point showed dose reduction by mean of -6.4%. AR and RS points showed an increased dose in M position by a mean of 16.5% and 10%, respectively. Conclusion: Current dosimetry procedure serves as a model with time-dose pattern planned for S position, but delivered in M position, without dose optimization. Prioritization of comfort and position can be considered in conjunction with optimization of dose

  11. Cytogenetic Reconstruction of Gamma-Ray Doses Delivered to Atomic Bomb Survivors: Dealing with Wide Distributions of Photon Energies and Contributions from Hematopoietic Stem/Progenitor Cells.

    Science.gov (United States)

    Nakamura, Nori; Hirai, Yuko; Kodama, Yoshiaki; Hamasaki, Kanya; Cullings, Harry M; Cordova, Kismet A; Awa, Akio

    2017-08-11

    Retrospective estimation of the doses received by atomic bomb (A-bomb) survivors by cytogenetic methods has been hindered by two factors: One is that the photon energies released from the bomb were widely distributed, and since the aberration yield varies depending on the energy, the use of monoenergetic (60)Co gamma radiation to construct a calibration curve may bias the estimate. The second problem is the increasing proportion of newly formed lymphocytes entering into the lymphocyte pool with increasing time intervals since the exposures. These new cells are derived from irradiated precursor/stem cells whose radiosensitivity may differ from that of blood lymphocytes. To overcome these problems, radiation doses to tooth enamel were estimated using the electron spin resonance (ESR; or EPR, electron paramagnetic resonance) method and compared with the cytogenetically estimated doses from the same survivors. The ESR method is only weakly dependent on the photon energy and independent of the years elapsed since an exposure. Both ESR and cytogenetic doses were estimated from 107 survivors. The latter estimates were made by assuming that although a part of the cells examined could be lymphoid stem or precursor cells at the time of exposure, all the cells had the same radiosensitivity as blood lymphocytes, and that the A-bomb gamma-ray spectrum was the same as that of the (60)Co gamma rays. Subsequently, ESR and cytogenetic endpoints were used to estimate the kerma doses using individual DS02R1 information on shielding conditions. The results showed that the two sets of kerma doses were in close agreement, indicating that perhaps no correction is needed in estimating atomic bomb gamma-ray doses from the cytogenetically estimated (60)Co gamma-ray equivalent doses. The present results will make it possible to directly compare cytogenetic doses with the physically estimated doses of the survivors, which would pave the way for testing whether or not there are any systematic

  12. Hardening electronic devices against very high total dose radiation environments

    Science.gov (United States)

    Buchanan, B.; Shedd, W.; Roosild, S.; Dolan, R.

    1972-01-01

    The possibilities and limitations of hardening silicon semiconductor devices to the high neutron and gamma radiation levels and greater than 10 to the eighth power rads required for the NERVA nuclear engine development are discussed. A comparison is made of the high dose neutron and gamma hardening potential of bipolar, metal insulator semiconductors and junction field effect transistors. Experimental data is presented on device degradation for the high neutron and gamma doses. Previous data and comparisons indicate that the JFET is much more immune to the combined neutron displacement and gamma ionizing effects than other transistor types. Experimental evidence is also presented which indicates that p channel MOS devices may be able to meet the requirements.

  13. High-dose desvenlafaxine in outpatients with major depressive disorder.

    Science.gov (United States)

    Ferguson, James M; Tourian, Karen A; Rosas, Gregory R

    2012-09-01

    This study investigated the safety and efficacy of long-term treatment with high-dose desvenlafaxine (administered as desvenlafaxine succinate) in major depressive disorder (MDD). In this multicenter, open-label study, adult outpatients with MDD aged 18-75 were treated with flexible doses of desvenlafaxine (200-400 mg/d) for ≤ 1 year. Safety assessments included monitoring of treatment-emergent adverse events (TEAEs), patient discontinuations due to adverse events, electrocardiograms, vital signs, and laboratory determinations. The primary efficacy measure was mean change from baseline in the 17-item Hamilton Rating Scale for Depression [HAM-D(17)] total score. The mean daily desvenlafaxine dose range over the duration of the trial was 267-356 mg (after titration). The most frequent TEAEs in the safety population (n = 104) were nausea (52%) and headache (41%), dizziness (31%), insomnia (29%), and dry mouth (27%). All TEAEs were mild or moderate in severity. Thirty-four (33%) patients discontinued from the study because of TEAEs; nausea (12%) and dizziness (9%) were the most frequently cited reasons. The mean change in HAM-D(17) total score for the intent-to-treat population (n = 99) was -9.9 at the last on-therapy visit in the last-observation-carried-forward analysis and -14.0 at month 12 in the observed cases analysis. Conclusion High-dose desvenlafaxine (200-400 mg/d) was generally safe and effective in the long-term treatment of MDD.

  14. Time-driven activity-based costing of low-dose-rate and high-dose-rate brachytherapy for low-risk prostate cancer.

    Science.gov (United States)

    Ilg, Annette M; Laviana, Aaron A; Kamrava, Mitchell; Veruttipong, Darlene; Steinberg, Michael; Park, Sang-June; Burke, Michael A; Niedzwiecki, Douglas; Kupelian, Patrick A; Saigal, Christopher

    Cost estimates through traditional hospital accounting systems are often arbitrary and ambiguous. We used time-driven activity-based costing (TDABC) to determine the true cost of low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy for prostate cancer and demonstrate opportunities for cost containment at an academic referral center. We implemented TDABC for patients treated with I-125, preplanned LDR and computed tomography based HDR brachytherapy with two implants from initial consultation through 12-month followup. We constructed detailed process maps for provision of both HDR and LDR. Personnel, space, equipment, and material costs of each step were identified and used to derive capacity cost rates, defined as price per minute. Each capacity cost rate was then multiplied by the relevant process time and products were summed to determine total cost of care. The calculated cost to deliver HDR was greater than LDR by $2,668.86 ($9,538 vs. $6,869). The first and second HDR treatment day cost $3,999.67 and $3,955.67, whereas LDR was delivered on one treatment day and cost $3,887.55. The greatest overall cost driver for both LDR and HDR was personnel at 65.6% ($4,506.82) and 67.0% ($6,387.27) of the total cost. After personnel costs, disposable materials contributed the second most for LDR ($1,920.66, 28.0%) and for HDR ($2,295.94, 24.0%). With TDABC, the true costs to deliver LDR and HDR from the health system perspective were derived. Analysis by physicians and hospital administrators regarding the cost of care afforded redesign opportunities including delivering HDR as one implant. Our work underscores the need to assess clinical outcomes to understand the true difference in value between these modalities. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  15. Pressures delivered by nasal high flow oxygen during all phases of the respiratory cycle.

    Science.gov (United States)

    Parke, Rachael L; McGuinness, Shay P

    2013-10-01

    Nasal high flow (NHF) oxygen therapy and CPAP are modes of noninvasive respiratory support used to improve respiratory function in multiple patient groups. Both therapies provide positive pressure, although this varies during the respiratory cycle. The purpose of this study was to measure and compare the airway pressure generated during different phases of the respiratory cycle in patients receiving NHF at various gas flows. Patients scheduled for elective cardiac surgery were invited to participate. Nasopharyngeal pressure measurements were performed using NHF with gas flows of 30, 40, and 50 L/min. All measurements were performed in random order, with the subject breathing with mouth closed. During NHF the mean ± SD nasopharyngeal airway pressures were 1.5 ± 0.6, 2.2 ± 0.8, and 3.1 ± 1.2 at 30, 40, and 50 L/min using NHF. Analyses also determined the mean peak expiratory and mean expiratory plateau pressures. The expiratory pressure during NHF was higher than the mean pressure previously reported for NHF. This may account in part for the disproportional clinical effects seen with NHF. (Australian Clinical Trials Registry www.anzctr.org.au ACTRN12609000305224).

  16. [Prostate cancer boost using high-dose-rate brachytherapy: impact of the learning curve on the dosimetry].

    Science.gov (United States)

    Benhaïm, C; Chand, M-È; Gal, J; Hijazi, H; Gautier, M; Hannoun-Lévi, J-M

    2014-11-01

    To analyse the influence of the learning curve on dosimetric data for high-dose-rate brachytherapy prostate cancer boost. From February 2009 to May 2012, after a first course of external beam radiation therapy (46Gy/23 fractions), 124 patients underwent high-dose-rate brachytherapy boost using Plato™ (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden). The impact of the learning curve on the dosimetric quality of the prostate implant was assessed. The dosimetric data have been analysed: clinical target volume (CTV), D90 (dose to 90 % of CTV), D100, V100 (part on the CTV receiving 100 % of the dose), V150, V200 and DHI (dose non-homogeneity index). The doses delivered to 0.1, 1 and 2 cm(3) of the rectum and urethra were calculated. During the study period (39 months), a significant reduction of V150 (PD100 (P=0.3). This study confirms that the dosimetric quality of high-dose-rate brachytherapy prostate implant is significantly improved during the learning curve period. Copyright © 2014 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  17. High-dose secondary calibration laboratory accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Humphreys, J.C. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1993-12-31

    There is a need for high-dose secondary calibration laboratories to serve the multi-billion dollar radiation processing industry. This need is driven by the desires of industry for less costly calibrations and faster calibration-cycle response time. Services needed include calibration irradiations of routine processing dosimeters and the supply of reference standard transfer dosimeters for irradiation in the production processing facility. In order to provide measurement quality assurance and to demonstrate consistency with national standards, the high-dose secondary laboratories would be accredited by means of an expansion of an existing National Voluntary Laboratory Accreditation Program. A laboratory performance criteria document is under development to implement the new program.

  18. Gemcitabine radiosensitization after high-dose samarium for osteoblastic osteosarcoma.

    Science.gov (United States)

    Anderson, Peter M; Wiseman, Gregory A; Erlandson, Linda; Rodriguez, Vilmarie; Trotz, Barbara; Dubansky, Stephen A; Albritton, Karen

    2005-10-01

    Osteoblastic metastases and osteosarcoma can avidly concentrate bone-seeking radiopharmaceuticals. We sought to increase effectiveness of high-dose (153)Samarium ethylenediaminetetramethylenephosphonate (153Sm-EDTMP, Quadramet) on osteosarcomas using a radiosensitizer, gemcitabine. Fourteen patients with osteoblastic lesions were treated with 30 mCi/kg 153Sm-EDTMP. Gemcitabine was administered 1 day after samarium infusion. Residual total body radioactivity was within the safe range of 1 year, there have been no durable responses. Thus, although high-dose 153Sm-EDTMP + gemcitabine has moderate palliative activity (improved pain; radiologic responses) in this poor-risk population, additional measures of local and systemic control are required for durable control of relapsed osteosarcoma with osteoblastic lesions. The strategy of radioactive drug binding to a target followed by a radiosensitizer may provide synergy and improved response rate.

  19. Methodology of high dose research in medical radiodiagnostic; Metodologia de investigacao de doses elevadas em radiodiagnostico medico

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, Adriana E.; Martins, Cintia P. de S., E-mail: ird@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-11-01

    This work has as main purpose to study occupational exposure in diagnostic radiology in medical cases of high doses recorded in 2011 at the national level . These doses were recorded by monitoring individual of the occupationally exposed individuals (OEI's). This monitoring of the doses received by ionizing radiation has as main objective to ensure that the principle of dose limitation is respected. In this study it were evaluated doses of 372 OEI's radiology in different Brazilian states. Doses were extracted from the database of Sector Management Doses of the Institute for Radioprotection and Dosimetry - IRD/CNEN-RJ, Brazil. The information from the database provide reports of doses from several states, which allows to quantify statistically, showing those with the highest doses in four areas: dose greater than or equal to 20 mSv apron and chest and dose greater than or equal to 100 mSv apron and chest. The identification of these states allows the respective Sanitary Surveillance (VISA), be aware of the events and make plans to reduce them. This study clarified the required procedures when there is a record of high dose emphasizing the importance of using protective radiological equipment, dosimeter and provide a safety environment work by maintaining work equipment. Proposes the ongoing training of professionals, emphasizing the relevance of the concepts of radiation protection and the use of the questionnaire with their investigative systematic sequence, which will allow quickly and efficiently the success the investigations.

  20. Image-guided high dose rate endorectal brachytherapy.

    Science.gov (United States)

    Devic, Slobodan; Vuong, Té; Moftah, Belal; Evans, Michael; Podgorsak, Ervin B; Poon, Emily; Verhaegen, Frank

    2007-11-01

    Fractionated high dose rate endorectal brachytherapy (HDR-EBT) using CT-based treatment planning is an alternative method for preoperative down-sizing and down-staging of advanced rectal adeno-carcinomas. The authors present an image guidance procedure that was developed to ensure daily dose reproducibility for the four brachytherapy treatment fractions. Since the applicator might not be placed before each treatment fraction inside the rectal lumen in the same manner as it was placed during the 3D CT volume acquisition used for treatment planning, there is a shift along the catheter axis that may have to be performed. The required shift is determined by comparison of a daily radiograph with the treatment planning digitally-reconstructed radiograph (DRR). A procedure is developed for DRR reconstruction from the 3D data set used for the treatment planning, and two possible daily longitudinal shifts are illustrated: above and below the planning dose distribution. The authors also describe the procedure for rotational alignment illustrated on a clinical case. Reproduction of the treatment planned dose distribution on a daily basis is crucial for the success of fractionated 3D based brachytherapy treatments. Due to the cylindrical symmetry of the applicator used for preoperative HDR-EBT, two types of adjustments are necessary: applicator rotation and dwell position shift along the applicator's longitudinal axis. The impact of the longitudinal applicator shift prior to treatment delivery for 62 patients treated in our institution is also assessed.

  1. SU-E-T-315: The Change of Optically Stimulated Luminescent Dosimeters (OSLDs) Sensitivity by Accumulated Dose and High Dose

    Energy Technology Data Exchange (ETDEWEB)

    Han, S; Jung, H; Kim, M; Ji, Y; Kim, K [University of Science and Technology, Daejeon (Korea, Republic of); Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Choi, S; Park, S; Yoo, H [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Yi, C [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2014-06-01

    Purpose: The objective of this study is to evaluate radiation sensitivity of optical stimulated luminance dosimeters (OSLDs) by accumulated dose and high dose. Methods: This study was carried out in Co-60 unit (Theratron 780, AECL, and Canada) and used InLight MicroStar reader (Landauer, Inc., Glenwood, IL) for reading. We annealed for 30 min using optical annealing system which contained fluorescent lamps (Osram lumilux, 24 W, 280 ∼780 nm). To evaluate change of OSLDs sensitivity by repeated irradiation, the dosimeters were repeatedly irradiated with 1 Gy. And whenever a repeated irradiation, we evaluated OSLDs sensitivity. To evaluate OSLDs sensitivity after accumulated dose with 5 Gy, We irradiated dose accumulatively (from 1 Gy to 5 Gy) without annealing. And OSLDs was also irradiated with 15, 20, 30 Gy to certify change of OSLDs sensitivity after high dose irradiation. After annealing them, they were irradiated with 1Gy, repeatedly. Results: The OSLDs sensitivity increased up to 3% during irradiating seven times and decreased continuously above 8 times. That dropped by about 0.35 Gy per an irradiation. Finally, after 30 times irradiation, OSLDs sensitivity decreased by about 7%. For accumulated dose from 1 Gy to 5 Gy, OSLDs sensitivity about 1 Gy increased until 4.4% after second times accumulated dose compared with before that. OSLDs sensitivity about 1 Gy decreased by 1.6% in five times irradiation. When OSLDs were irradiated ten times with 1Gy after irradiating high dose (10, 15, 20 Gy), OSLDs sensitivity decreased until 6%, 9%, 12% compared with it before high dose irradiation, respectively. Conclusion: This study certified OSLDs sensitivity by accumulated dose and high dose. When irradiated with 1Gy, repeatedly, OSLDs sensitivity decreased linearly and the reduction rate of OSLDs sensitivity after high dose irradiation had dependence on irradiated dose.

  2. A Monte Carlo model for out-of-field dose calculation from high-energy photon therapy.

    Science.gov (United States)

    Kry, Stephen F; Titt, Uwe; Followill, David; Pönisch, Falk; Vassiliev, Oleg N; White, R Allen; Stovall, Marilyn; Salehpour, Mohammad

    2007-09-01

    As cancer therapy becomes more efficacious and patients survive longer, the potential for late effects increases, including effects induced by radiation dose delivered away from the treatment site. This out-of-field radiation is of particular concern with high-energy radiotherapy, as neutrons are produced in the accelerator head. We recently developed an accurate Monte Carlo model of a Varian 2100 accelerator using MCNPX for calculating the dose away from the treatment field resulting from low-energy therapy. In this study, we expanded and validated our Monte Carlo model for high-energy (18 MV) photon therapy, including both photons and neutrons. Simulated out-of-field photon doses were compared with measurements made with thermoluminescent dosimeters in an acrylic phantom up to 55 cm from the central axis. Simulated neutron fluences and energy spectra were compared with measurements using moderated gold foil activation in moderators and data from the literature. The average local difference between the calculated and measured photon dose was 17%, including doses as low as 0.01% of the central axis dose. The out-of-field photon dose varied substantially with field size and distance from the edge of the field but varied little with depth in the phantom, except at depths shallower than 3 cm, where the dose sharply increased. On average, the difference between the simulated and measured neutron fluences was 19% and good agreement was observed with the neutron spectra. The neutron dose equivalent varied little with field size or distance from the central axis but decreased with depth in the phantom. Neutrons were the dominant component of the out-of-field dose equivalent for shallow depths and large distances from the edge of the treatment field. This Monte Carlo model is useful to both physicists and clinicians when evaluating out-of-field doses and associated potential risks.

  3. Dosimetric feasibility of ablative dose escalated focal monotherapy with MRI-guided high-dose-rate (HDR) brachytherapy for prostate cancer.

    Science.gov (United States)

    Hosni, Ali; Carlone, Marco; Rink, Alexandra; Ménard, Cynthia; Chung, Peter; Berlin, Alejandro

    2017-01-01

    To determine the dosimetric feasibility of dose-escalated MRI-guided high-dose-rate brachytherapy (HDR-BT) focal monotherapy for prostate cancer (PCa). In all patients, GTV was defined with mpMRI, and deformably registered onto post-catheter insertion planning MRI. PTV included the GTV plus 9mm craniocaudal and 5mm in every other direction. In discovery-cohort, plans were obtained for each PTV independently aiming to deliver ⩾16.5Gy/fraction (two fraction schedule) while respecting predefined organs-at-risk (OAR) constraints or halted when achieved equivalent single-dose plan (24Gy). Dosimetric results of original and focal HDR-BT plans were evaluated to develop a planning protocol for the validation-cohort. In discovery-cohort (20-patients, 32-GTVs): PTV D95% ⩾16.5Gy could not be reached in a single plan (3%) and was accomplished (range 16.5-23.8Gy) in 15 GTVs (47%). Single-dose schedule was feasible in 16 (50%) plans. In the validation-cohort (10-patients, 10-GTVs, two separate implants each): plans met acceptable and ideal criteria in 100% and 43-100% respectively. Migration to single-dose treatment schedule was feasible in 7 implants (35%), without relaxing OAR's constraints or increasing the dose (D100% and D35%) to mpMRI-normal prostate (p>0.05). Focal ablative dose-escalated radiation is feasible with the proposed protocol. Prospective studies are warranted to determine the clinical outcomes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Dose-volume parameters and clinical outcome of CT-guided free-hand high-dose-rate interstitial brachytherapy for cervical cancer

    Science.gov (United States)

    Wang, Yi; Ye, Wei-Jun; Du, Le-Hui; Li, Ai-Ju; Ren, Yu-Feng; Cao, Xin-Ping

    2012-01-01

    Currently, image-based 3-dimentional (3D) planning brachytherapy allows for a better assessment of gross tumor volume (GTV) and the definition and delineation of target volume in cervix cancer. In this study, we investigated the feasibility of our novel computed tomography (CT)-guided free-hand high-dose-rate interstitial brachytherapy (HDRISBT) technique for cervical cancer by evaluating the dosimetry and preliminary clinical outcome of this approach. Dose-volume histogram (DVH) parameters were analyzed according to the Gynecological GEC-ESTRO Working Group recommendations for image-based 3D treatment in cervical cancer. Twenty cervical cancer patients who underwent CT-guided free-hand HDRISBT between March 2009 and June 2010 were studied. With a median of 5 (range, 4–7) implanted needles for each patient, the median dose of brachytherapy alone delivered to 90% of the target volume (D90) was 45 (range, 33–54) Gyα/β10 for high-risk clinical target volume (HR-CTV) and 30 (range, 20–36) Gyα/β10 for intermediate-risk clinical target volume (IR-CTV). The percentage of the CTV covered by the prescribed dose (V100) of HR-CTV with brachytherapy alone was 81.9%–99.2% (median, 96.7%). With an additional dose of external beam radiotherapy (EBRT), the median D90 was 94 (range, 83–104) Gyα/β10 for HR-CTV and 77 (range, 70–87) Gyα/β10 for IR-CTV; the median dose delivered to 100% of the target volume (D100) was 75 (range, 66–84) Gyα/β10 for HR-CTV and 65 (range, 57–73) Gyα/β10 for IR-CTV. The minimum dose to the most irradiated 2 cc volume (D2cc) was 73–96 (median, 83) Gyα/β3 for the bladder, 64–98 (median, 73) Gyα/β3 for the rectum, and 52–69 (median, 61) Gyα/β3 for the sigmoid colon. After a median follow-up of 15 months (range, 3–24 months), two patients experienced local failure, and 1 showed internal iliac nodal metastasis. Despite the relatively small number of needles used, CT-guided HDRISBT for cervical cancer showed favorable

  5. High-dose irradiation of food; Hochdosisbestrahlung von Lebensmitteln

    Energy Technology Data Exchange (ETDEWEB)

    Diehl, J.F.

    1999-07-01

    Studies performed on behalf of the International Project on Food Irradiation in the period from 1971 until 1980 resulted in the concluding statement that ''.the irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard; hence, toxicological testing of foods so treated is no longer required.'' Since then, licenses for food irradiation have been restricted to this maximum dose in any country applying this technology. Further testing programmes have been carried out investigating the wholesomeness or hazards of high-dose irradiation, but there has been little demand so far by the food industry for licensing of high-dose irradiation, as there is only a small range of products whose irradiation at higher doses offers advantages for given, intended use. These include eg. spices, dried herbs, meat products in flexible pouch packagings for astronauts, or patients with immune deficiencies. (orig./CB) [German] Die im Rahmen des Projekts erteilten Auftraege betrafen nur solche Lebensmittel, die im Dosisbereich < 10 kGy bestrahlt waren, da der Bereich hoeherer Dosen durch die amerikanischen Untersuchungen abgedeckt war. Als das Joint FAO/IAEA/WHO Expert Committee on Food Irradiation (JECFI) 1980 in Genf tagte, um ueber die gesundheitliche Bewertung bestrahlter Lebensmittel zu beraten, waren jedoch die in den Vereinigten Staaten laufenden, sehr umfangreichen Langzeitversuche mit strahlensterilisiertem Haehnchenfleisch (Dosis 58 kGy) noch nicht abgeschlossen. Das Komitee beschraenkte sich daher auf die Bewertung der vom Internationalen Projekt vorgelegten Ergebnisse. Die Schlussfolgerung 'the irradiation of any food commodity up to an overall average dose of 10 kGy presents no toxicological hazard; hence, toxicological testing of foods so treated is no longer required'beendete die jahrzehntelange Debatte ueber die gesundheitliche Unbedenklichkeit von im niedrigen (bis 1 kGy) und mittleren (1 bis 10 k

  6. Measuring uncertainty in dose delivered to the cochlea due to setup error during external beam treatment of patients with cancer of the head and neck

    Energy Technology Data Exchange (ETDEWEB)

    Yan, M.; Lovelock, D.; Hunt, M.; Mechalakos, J.; Hu, Y.; Pham, H.; Jackson, A., E-mail: jacksona@mskcc.org [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York 10065 (United States)

    2013-12-15

    Purpose: To use Cone Beam CT scans obtained just prior to treatments of head and neck cancer patients to measure the setup error and cumulative dose uncertainty of the cochlea. Methods: Data from 10 head and neck patients with 10 planning CTs and 52 Cone Beam CTs taken at time of treatment were used in this study. Patients were treated with conventional fractionation using an IMRT dose painting technique, most with 33 fractions. Weekly radiographic imaging was used to correct the patient setup. The authors used rigid registration of the planning CT and Cone Beam CT scans to find the translational and rotational setup errors, and the spatial setup errors of the cochlea. The planning CT was rotated and translated such that the cochlea positions match those seen in the cone beam scans, cochlea doses were recalculated and fractional doses accumulated. Uncertainties in the positions and cumulative doses of the cochlea were calculated with and without setup adjustments from radiographic imaging. Results: The mean setup error of the cochlea was 0.04 ± 0.33 or 0.06 ± 0.43 cm for RL, 0.09 ± 0.27 or 0.07 ± 0.48 cm for AP, and 0.00 ± 0.21 or −0.24 ± 0.45 cm for SI with and without radiographic imaging, respectively. Setup with radiographic imaging reduced the standard deviation of the setup error by roughly 1–2 mm. The uncertainty of the cochlea dose depends on the treatment plan and the relative positions of the cochlea and target volumes. Combining results for the left and right cochlea, the authors found the accumulated uncertainty of the cochlea dose per fraction was 4.82 (0.39–16.8) cGy, or 10.1 (0.8–32.4) cGy, with and without radiographic imaging, respectively; the percentage uncertainties relative to the planned doses were 4.32% (0.28%–9.06%) and 10.2% (0.7%–63.6%), respectively. Conclusions: Patient setup error introduces uncertainty in the position of the cochlea during radiation treatment. With the assistance of radiographic imaging during setup

  7. EPR/Homotaurine: A possible dosimetry system for high doses

    Energy Technology Data Exchange (ETDEWEB)

    Maghraby, A., E-mail: maghrabism@yahoo.com [National Institute of Standards (NIS) - Radiation Dosimetry Department - Tersa st. 12211 Giza, P.O. Box 136 (Egypt); Salama, E. [Physics Department, Faculty of Science, Ain Shams University, 11566 Cairo (Egypt); Mansour, A. [National Center for Radiation Research and Technology, Atomic Energy Authority, Nasr City, Cairo (Egypt)

    2011-12-11

    An EPR investigation of radiation induced radicals in Homotaurine revealed that there are two types of radicals produced after exposure to gamma radiation ({sup 60}Co). EPR spectra were recorded and analyzed; also the microwave power saturation curves for both radicals were studied. The effect of change in modulation amplitude on peak-to-peak signal height and line width was investigated; this is in addition to the evaluation of energy dependence parameters compared to soft tissue and alanine dosimeters. Response of Homotaurine to different radiation doses (0.5 kGy-50 kGy) was studied and found to follow a linear relationship. Radiation induced radicals in Homotaurine persisted and showed a noticeable stability over 30 days following irradiation. It was found that Homotaurine possesses good dosimetric properties using EPR spectroscopy in high doses and is characterized by its simple spectrum.

  8. EPR/Homotaurine: A possible dosimetry system for high doses

    Science.gov (United States)

    Maghraby, A.; Salama, E.; Mansour, A.

    2011-12-01

    An EPR investigation of radiation induced radicals in Homotaurine revealed that there are two types of radicals produced after exposure to gamma radiation (60Co). EPR spectra were recorded and analyzed; also the microwave power saturation curves for both radicals were studied. The effect of change in modulation amplitude on peak-to-peak signal height and line width was investigated; this is in addition to the evaluation of energy dependence parameters compared to soft tissue and alanine dosimeters. Response of Homotaurine to different radiation doses (0.5 kGy-50 kGy) was studied and found to follow a linear relationship. Radiation induced radicals in Homotaurine persisted and showed a noticeable stability over 30 days following irradiation. It was found that Homotaurine possesses good dosimetric properties using EPR spectroscopy in high doses and is characterized by its simple spectrum.

  9. Survival of tumor cells after proton irradiation with ultra-high dose rates

    Directory of Open Access Journals (Sweden)

    Belka Claus

    2011-10-01

    Full Text Available Abstract Background Laser acceleration of protons and heavy ions may in the future be used in radiation therapy. Laser-driven particle beams are pulsed and ultra high dose rates of >109 Gy s-1may be achieved. Here we compare the radiobiological effects of pulsed and continuous proton beams. Methods The ion microbeam SNAKE at the Munich tandem accelerator was used to directly compare a pulsed and a continuous 20 MeV proton beam, which delivered a dose of 3 Gy to a HeLa cell monolayer within Results At 10 h after pulsed irradiation, the fraction of G2 cells was significantly lower than after irradiation with the continuous beam, while all other endpoints including colony formation were not significantly different. We determined the relative biological effectiveness (RBE for pulsed and continuous proton beams relative to x-irradiation as 0.91 ± 0.26 and 0.86 ± 0.33 (mean and SD, respectively. Conclusions At the dose rates investigated here, which are expected to correspond to those in radiation therapy using laser-driven particles, the RBE of the pulsed and the (conventional continuous irradiation mode do not differ significantly.

  10. High-dose-rate interstitial brachytherapy for the treatment of penile carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Petera, J.; Odrazka, K.; Zouhar, M.; Bedrosova, J.; Dolezel, M. [Dept. of Oncology and Radiotherapy, Charles Univ. Medical School and Teaching Hospital, Hradec Kralove (Czech Republic)

    2004-02-01

    Background: interstitial low-dose-rate (LDR) brachytherapy allows conservative treatment of T1-T2 penile carcinoma. High-dose-rate (HDR) is often considered to be dangerous for interstitial implants because of a higher risk of complications, but numerous reports suggest that results may be comparable to LDR. Nevertheless, there are no data in the literature available regarding HDR interstitial brachytherapy for carcinoma of the penis. Case report: a 64-year-old man with T1 NO MO epidermoid carcinoma of the glans is reported. Interstitial HDR brachytherapy was performed using the stainless hollow needle technique and a breast template for fixation and good geometry. The dose delivered was 18 x 3 Gy twice daily. Results: after 232 days from brachytherapy, the patient was without any evidence of the tumor, experienced no serious radiation-induced complications, and had a fully functional organ. Conclusion: HDR interstitial brachytherapy is feasible in selected case of penis carcinoma, when careful planning and small single fractions are used. (orig.)

  11. High doses of vitamin A impair iron absorption

    Directory of Open Access Journals (Sweden)

    Gabriel FR

    2012-10-01

    Full Text Available Fabíola Rainato Gabriel, Vivian MM Suen, Julio Sergio Marchini, José Eduardo Dutra de OliveiraDivision of Clinical Nutrition, Department of Internal Medicine, Ribeirão Preto School of Medicine, São Paulo University, São Paulo, BrazilObjective: The present study aimed to determine the influence of vitamin A on iron absorption when vitamin A and iron are administered together orally compared with the administration of iron alone.Methods: This was a randomized double-blind clinical trial conducted on healthy men with normal red blood cell indices. Five experiments were performed, with iron (10 mg; iron (10 mg plus vitamin A (450, 900 and 1800 µg, and placebo. After an 8-hour fast, basal (T0 blood samples were collected: basal (T0, 2 hours (T1, and 4 hours (T2 after the ingestion of the compounds to be studied. Iron was determined by inductively coupled plasma mass spectrometry. Serum ferritin was determined by an immunometric method, ie, by chemoluminescent enzyme immunoassay. Plasma retinol was measured by high-pressure liquid chromatography. Serum curves and the sum of the area under the curve adjusted to the mixed effects linear model were determined (P < 0.05.Results: Vitamin A at the doses of 450 and 900 µg had a stimulating effect, which, however, did not differ significantly from that of experiment 1 in which iron was used alone. At the dose of 1800 µg, vitamin A had a negative effect on iron absorption.Conclusion: High doses of vitamin A may cause lower serum iron levels, whereas a low dose favors iron absorption.Keywords: iron absorption, serum iron, vitamin A, oral iron, oral supplement

  12. Study of teflon pads as high doses dosemeters; Estudo de pastilhas de teflon como dosimetros de doses altas

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Maria Ines; Caldas, Linda V.E., E-mail: miteixeira@ipen.br, E-mail: lcaldas@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-11-01

    The aim of this work is to study the Teflon, which is used as a binder in the manufacture of dosimetric tablets, for the feasibility of this material as high dose dosemeter. In this paper we used the technique of thermally stimulated luminescence (OSL) to characterize the dosimetric properties of Teflon. Teflon samples were exposed to different doses of radiation, using a source of gamma radiation ({sup 60}Co). It was obtained dose-response curve between 100 Gy to 50 kGy and reproducibility of OSL response. The preliminary results show that Teflon is a useful material to high dose dosimetry.

  13. High-dose vs low-dose proton pump inhibitors for upper gastrointestinal bleeding:A meta-analysis

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    AIM:To evaluate the efficacy of high-dose proton pump inhibitors(PPIs)vs low-dose PPIs for patients with upper gastrointestinal bleeding.METHODS:PubMed,Embase,the Cochrane Library,and Web of Science were searched to identify relevant randomized controlled trials(RCTs).Eligible trials were RCTs that compared high-dose PPI with low-dose PPI following endoscopic hemostasis.The primary endpoint was rebleeding;secondary endpoints were patient numbers that needed surgery,and mortality.The meta-analysis was perfor...

  14. Identification of dose-reduction techniques for BWR and PWR repetitive high-dose jobs

    Energy Technology Data Exchange (ETDEWEB)

    Dionne, B.J.; Baum, J.W.

    1984-01-01

    As a result of concern about the apparent increase in collective radiation dose to workers at nuclear power plants, this project will provide information to industry in preplanning for radiation protection during maintenance operations. This study identifies Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) repetitive jobs, and respective collective dose trends and dose reduction techniques. 3 references, 2 tables. (ACR)

  15. SU-F-P-19: Fetal Dose Estimate for a High-Dose Fluoroscopy Guided Intervention Using Modern Data Tools

    Energy Technology Data Exchange (ETDEWEB)

    Moirano, J [University of Washington, Seattle, WA (United States)

    2016-06-15

    Purpose: An accurate dose estimate is necessary for effective patient management after a fetal exposure. In the case of a high-dose exposure, it is critical to use all resources available in order to make the most accurate assessment of the fetal dose. This work will demonstrate a methodology for accurate fetal dose estimation using tools that have recently become available in many clinics, and show examples of best practices for collecting data and performing the fetal dose calculation. Methods: A fetal dose estimate calculation was performed using modern data collection tools to determine parameters for the calculation. The reference point air kerma as displayed by the fluoroscopic system was checked for accuracy. A cumulative dose incidence map and DICOM header mining were used to determine the displayed reference point air kerma. Corrections for attenuation caused by the patient table and pad were measured and applied in order to determine the peak skin dose. The position and depth of the fetus was determined by ultrasound imaging and consultation with a radiologist. The data collected was used to determine a normalized uterus dose from Monte Carlo simulation data. Fetal dose values from this process were compared to other accepted calculation methods. Results: An accurate high-dose fetal dose estimate was made. Comparison to accepted legacy methods were were within 35% of estimated values. Conclusion: Modern data collection and reporting methods ease the process for estimation of fetal dose from interventional fluoroscopy exposures. Many aspects of the calculation can now be quantified rather than estimated, which should allow for a more accurate estimation of fetal dose.

  16. Clinical application of a OneDose(TM) MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Kinhikar, Rajesh A [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Sharma, Pramod K [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Tambe, Chandrashekhar M [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Mahantshetty, Umesh M [Department of Radiation Oncology, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Sarin, Rajiv [Advanced Centre for Training Research and Education in Cancer, Kharghar, Navi Mumbai (India); Deshpande, Deepak D [Department of Medical Physics, Tata Memorial Hospital, Parel, Mumbai 400 012 (India); Shrivastava, Shyam K [Department of Radiation Oncology, Tata Memorial Hospital, Parel, Mumbai 400 012 (India)

    2006-07-21

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose(TM) in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs. (note)

  17. High doses of recombinant erythropoietin stimulate platelet production in mice

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, T.P.; Cottrell, M.B.; Clift, R.E.; Cullen, W.C.; Lin, F.K.

    1987-07-01

    Previously, recombinant erythropoietin (rEpo) was shown to increase the number and size of megakaryocytic colonies in vitro, and in vivo it elevates the number of megakaryocytes in mouse spleens. To test the hypothesis that rEpo would stimulate platelet production in mice, both normal mice and mice in rebound-thrombocytosis were injected with rEpo and the %35S incorporation into platelets was measured. A thrombocytopoiesis-stimulating factor (TSF or thrombopoietin) was used as a positive control. rEpo increased isotopic incorporation into platelets of both normal mice and mice in rebound-thrombocytosis, as did TSF, but required large doses (15 U rEpo/mouse). In other mice, hematocrits, platelet counts, platelet sizes, and 24-hr %35S incorporation into platelets were measured 2 days after injection of two equally divided doses of either rEpo or TSF. Significant increases in both platelet sizes and %35S incorporation into platelets were found after injections of 15 U rEpo/mouse or 2.3 U TSF/mouse. These data indicate that rEpo, at high doses, will stimulate platelet production in mice, and may suggest molecular similarities between rEpo and TSF and their ability to compete for common receptor sites on megakaryocytes and their progenitor cells.

  18. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Ken; Mitomo, Masanori [Osaka National Hospital (Japan); Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji [Osaka Prefectural Center for Adult Diseases (Japan); Yoshida, Mineo [Sanda City Hospital, Hyogo (Japan)

    2002-12-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients

  19. Performance assessment of the BEBIG MultiSource high dose rate brachytherapy treatment unit.

    Science.gov (United States)

    Palmer, Antony; Mzenda, Bongile

    2009-12-21

    A comprehensive system characterisation was performed of the Eckert & Ziegler BEBIG GmbH MultiSource High Dose Rate (HDR) brachytherapy treatment unit with an (192)Ir source. The unit is relatively new to the UK market, with the first installation in the country having been made in the summer of 2009. A detailed commissioning programme was devised and is reported including checks of the fundamental parameters of source positioning, dwell timing, transit doses and absolute dosimetry of the source. Well chamber measurements, autoradiography and video camera analysis techniques were all employed. The absolute dosimetry was verified by the National Physical Laboratory, UK, and compared to a measurement based on a calibration from PTB, Germany, and the supplied source certificate, as well as an independent assessment by a visiting UK centre. The use of the 'Krieger' dosimetry phantom has also been evaluated. Users of the BEBIG HDR system should take care to avoid any significant bend in the transfer tube, as this will lead to positioning errors of the source, of up to 1.0 mm for slight bends, 2.0 mm for moderate bends and 5.0 mm for extreme curvature (depending on applicators and transfer tube used) for the situations reported in this study. The reason for these errors and the potential clinical impact are discussed. Users should also note the methodology employed by the system for correction of transit doses, and that no correction is made for the initial and final transit doses. The results of this investigation found that the uncorrected transit doses lead to small errors in the delivered dose at the first dwell position, of up to 2.5 cGy at 2 cm (5.6 cGy at 1 cm) from a 10 Ci source, but the transit dose correction for other dwells was accurate within 0.2 cGy. The unit has been mechanically reliable, and source positioning accuracy and dwell timing have been reproducible, with overall performance similar to other existing HDR equipment. The unit is capable of high

  20. Labour induction with an intermediate-dose oxytocin regimen has advantages over a high-dose regimen.

    Science.gov (United States)

    Manjula, B G; Bagga, R; Kalra, J; Dutta, S

    2015-05-01

    A total of 200 women planned for labour induction were randomised to receive high-dose oxytocin (6 mU/min with similar increments every 45 min) or intermediate-dose oxytocin (3 mU/min with similar increments every 45 min). Oxytocin solution was prepared with 30 units in 500 ml saline with which the infusion rate in ml/h is numerically equal to oxytocin in mU/min. We observed that the caesarean rate (18% vs 6%, p = 0.009), contraction abnormalities (35% vs 14%, p = 0.0005) and neonatal bilirubin levels (7.99 ± 2.70 vs 6.80 ± 2.65, p = 0.002) were higher with high-dose than with intermediate-dose. The induction-delivery interval (IDI) was similar (10 h 13 min with high-dose and 11 h 5 min with intermediate-dose; p = 0.237, NS). Nulliparous women benefited more with intermediate-dose as the caesarean rate was higher with high-dose (24.6% vs 7.9%, p = 0.011). Although the caesarean rate was higher in multiparous women with high-dose oxytocin, it was statistically not significant (5.7% vs 2.7%; p = 0.609). Oxytocin regimens for labour induction are usually high-dose (4-6 mU/min) or low-dose (1-1.5 mU/min). The former is associated with more contraction abnormalities and the latter with prolonged IDI; both result in an increased caesarean rate. In order to offset these disadvantages, an intermediate- dose regimen was selected. The increment interval of 45 min was selected in accordance with the pharmacokinetics of oxytocin. We observed a lower caesarean rate when compared with the high-dose regimen, without any increase in the IDI. Hence, we propose that the intermediate-dose oxytocin regimen should be preferred to the high-dose regimen for labour induction.

  1. Rectal dose-volume constraints in high-dose radiotherapy of localized prostate cancer.

    Science.gov (United States)

    Fiorino, Claudio; Sanguineti, Giuseppe; Cozzarini, Cesare; Fellin, Gianni; Foppiano, Franca; Menegotti, Loris; Piazzolla, Anna; Vavassori, Vittorio; Valdagni, Riccardo

    2003-11-15

    To investigate the relationship between rectal bleeding and dosimetric-clinical parameters in patients receiving three-dimensional conformal radiotherapy (3D-CRT) for localized prostate cancer. In a retrospective national study (AIROPROS01-01, AIRO: Associazione Italiana Radioterapia Oncologica), planning/clinical data for 245 consecutive patients with stage T1-4N0-x prostate carcinoma who underwent 3D-CRT to 70-78 Gy (ICRU point) were pooled from four Italian institutions. The correlation between late rectal bleeding and rectal dose-volume data (the percentage of rectum receiving more than 50, 55, 60, 65, 70, and 75 Gy [V(50-70)]) and other dosimetric and clinical parameters were investigated in univariate (log-rank) and multivariate (Cox regression model) analyses. Median follow-up was 2 years. Twenty-three patients were scored as late bleeders according to a modified RTOG definition (Grade 2: 16; Grade 3: 7); the actuarial 2-year rate was 9.2%. Excepting V75, all median and third quartile V(50-70) values were found to be significantly correlated with late bleeding at univariate analysis. The smallest p value was seen for V(50) below/above the third quartile value (66%). The V70 (cut-off value: 30%) was found to be also predictive for late bleeding. In the high-dose subgroup (74-78 Gy), Grade 3 bleeding was highly correlated with this constraint. The predictive value of both V(50) and V(70) was confirmed by multivariate analyses. The present article provides evidence for correlation between rectal DVH parameters and late rectal bleeding in patients treated with curative intent with 3D-CRT. To keep the rate of moderate/severe rectal bleeding below 5-10%, it seems advisable to limit V(50) to 60-65%, V(60) to 45-50%, and V70 to 25-30%.

  2. Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'

    Energy Technology Data Exchange (ETDEWEB)

    Salter, Bill J; Sarkar, Vikren; Wang, Brian; Szegedi, Martin; Rassiah-Szegedi, Prema [Department of Radiation Oncology, University of Utah, Salt Lake City, UT (United States); Shukla, Himanshu, E-mail: bill.salter@hci.utah.edu [Oncology Care Systems Group, Siemens Medical Solutions (USA), 4040 Nelson Avenue, Concord, CA (United States)

    2011-04-07

    Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units per minute (MU min{sup -1}) high dose rate bursts of dose are facilitated by a flattening-filter-free treatment beam on a Siemens Artiste (Oncology Care Systems, Siemens Medical Solutions, Concord, CA, USA) digital linear accelerator in a non-clinical configuration. Burst mode delivery differs from continuous mode delivery, used by Elekta's VMAT (Elekta Ltd, Crawley, UK) and Varian's RapidArc (Varian Medical Systems, Palo Alto, CA, USA) implementations, in that dose is not delivered while MLC leaves are moving. Instead, dose is delivered in bursts over very short arc angles and only after an MLC segment shape has been completely formed and verified by the controller. The new system was confirmed to be capable of delivering a wide array of clinically relevant treatment plans, without machine fault or other delivery anomalies. Dosimetric accuracy of the modulated arc platform, as well as the Prowess (Prowess Inc., Concord, CA, USA) prototype treatment planning version utilized here, was quantified and confirmed, and delivery times were measured as significantly brief, even with large hypofractionated doses. The burst mode modulated arc approach evaluated here appears to represent a capable, accurate and efficient delivery approach.

  3. Cation disorder in high-dose, neutron-irradiated spinel

    Energy Technology Data Exchange (ETDEWEB)

    Sickafus, K.E.; Larson, A.C.; Yu, N. [Los Alamos National Lab., CA (United States)] [and others

    1995-04-01

    The objective of this effort is to determine whether MgAl{sub 2}O{sub 4} spinel is a suitable ceramic for fusion applications. The crystal structures of MgAl{sub 2}O{sub 4} spinel single crystals irradiated to high neutron fluences [>5{times}10{sup 26} n/m{sup 2} (E{sub n}>0.1 MeV)] were examined by neutron diffraction. Crystal structure refinement of the highese dose sample indicated that the average scattering strength of the tetrahedral crystal sites decreased by {approx}20% while increasing by {approx}8% on octahedral sites.

  4. Krait bite requiring high dose antivenom: a case report.

    Science.gov (United States)

    Sharma, Sanjib Kumar; Koirala, Shekhar; Dahal, Gaheraj

    2002-03-01

    Anti snake venom (ASV) is the most specific therapy available for treatment of snakebite envenomation. The ASV available in Nepal are polyvalent ASV produced in India and are effective against envenomation by cobra and krait, the two most common species found in Eastern Nepal. Neurotoxic signs respond slowly and unconvincingly and continuous absorption of venom may cause recurrent neurotoxicity. Therefore, close observation and continuous administration of ASV is essential to save the victim. We report a case of neurotoxic envenomation due to bite by common krait (Bangarus caeruleus). The victim required very high dose of polyvalent ASV for reversal of neurological manifestations.

  5. Physical characteristics of the Selectron high dose rate intracavitary afterloader

    Energy Technology Data Exchange (ETDEWEB)

    Chenery, S.G.A.; Pla, M.; Podgorsak, E.B. (Royal Victoria Hospital, Montreal, Quebec (Canada); McGill Univ., Montreal, Quebec (Canada))

    1985-08-01

    The physics measurements on a Selectron high dose-rate afterloading cobalt-60 unit are reported. The installation was found to be acceptable from the standpoint of radiation safety and cost effectiveness; hospital bed space was saved as treatment could be on an outpatient basis. A source calibration 4% higher than the value stated by the manufacturer was obtained. Measurement of the ratio of exposure rate in water to that in air confirmed the calibration and the applicability of correction factors for routine clinical dosimetry recommended in the literature.

  6. High dose intravenous immunoglobulin may be complicated by myocardial infarction

    Directory of Open Access Journals (Sweden)

    Kolar Vishwanath Vinod

    2014-01-01

    Full Text Available Intravenous immunoglobulin [IVIg] is useful for treating several clinical conditions and is largely considered safe, without major adverse events. Here we report a case of acute ST elevation myocardial infarction associated with high dose IVIg administration in a previously healthy 69-year-old male patient of Guillain Barre syndrome. The case is being reported to emphasize the need for treating physicians to be aware of thrombotic complications associated with IVIg. The thrombotic complications associated with IVIg are reviewed in brief , and the measures to reduce them are discussed.

  7. Dose-volume parameters and clinical outcome of CT-guided freehand high-dose-rate interstitial brachytherapy for cervical cancer

    Institute of Scientific and Technical Information of China (English)

    Yi Wang; Wei-Jun Ye; Le-Hui Du; Ai-Ju Li; Yu-Feng Ren; Xin-Ping Cao

    2012-01-01

    Currently,image-based 3-dimentional (3D) planning brachytherapy allows for a better assessment of gross tumor volume (GTV) and the definition and delineation of target volume in cervix cancer.In this study,we investigated the feasibility of our novel computed tomography (CT)-guided free-hand high-doserate interstitial brachytherapy (HDRISBT) technique for cervical cancer by evaluating the dosimetry and preliminary clinical outcome of this approach.Dose-volume histogram (DVH) parameters were analyzed according to the Gynecological GEC-ESTRO Working Group recommendations for image-based 3D treatment in cervical cancer.Twenty cervical cancer patients who underwent CT-guided free-hand HDRISBT between March 2009 and June 2010 were studied.With a median of 5 (range,4-7) implanted needles for each patient,the median dose of brachytherapy alone delivered to 90% of the target volume (D90) was 45 (range,33-54) Gyα/β10 for high-risk clinical target volume (HR-CTV) and 30 (range,20-36)Gyα/β10 for intermediate-risk clinical target volume (IR-CTV).The percentage of the CTV covered by the prescribed dose (V100) of HR-CTV with brachytherapy alone was 81.9%-99.2% (median,96.7%).With an additional dose of external beam radiotherapy (EBRT),the median D90 was 94 (range,83-104) Gyα/β10 for HR-CTV and 77 (range,70-87) Gyα/β10 for IR-CTV; the median dose delivered to 100% of the target volume (D100) was 75 (range,66-84) Gyα/β10 for HR-CTV and 65 (range,57-73) Gyα/β10 for IR-CTV.The minimum dose to the most irradiated 2 cc volume (D2cc) was 73-96 (median,83) Gyα/β3 for the bladder,64-98 (median,73) Gyα/β3 for the rectum,and 52-69 (median,61) Gyα/β3 for the sigmoid colon.After a median follow-up of 15 months (range,3-24 months),two patients experienced local failure,and 1 showed internal lilac nodal metastasis.Despite the relatively small number of needles used,CT-guided HDRISBT for cervical cancer showed favorable DVH parameters and clinical outcome.

  8. Secondary radiation dose during high-energy total body irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Janiszewska, M.; Raczkowski, M. [Lower Silesian Oncology Center, Medical Physics Department, Wroclaw (Poland); Polaczek-Grelik, K. [University of Silesia, Medical Physics Department, Katowice (Poland); Szafron, B.; Konefal, A.; Zipper, W. [University of Silesia, Department of Nuclear Physics and Its Applications, Katowice (Poland)

    2014-05-15

    The goal of this work was to assess the additional dose from secondary neutrons and γ-rays generated during total body irradiation (TBI) using a medical linac X-ray beam. Nuclear reactions that occur in the accelerator construction during emission of high-energy beams in teleradiotherapy are the source of secondary radiation. Induced activity is dependent on the half-lives of the generated radionuclides, whereas neutron flux accompanies the treatment process only. The TBI procedure using a 18 MV beam (Clinac 2100) was considered. Lateral and anterior-posterior/posterior-anterior fractions were investigated during delivery of 2 Gy of therapeutic dose. Neutron and photon flux densities were measured using neutron activation analysis (NAA) and semiconductor spectrometry. The secondary dose was estimated applying the fluence-to-dose conversion coefficients. The main contribution to the secondary dose is associated with fast neutrons. The main sources of γ-radiation are the following: {sup 56}Mn in the stainless steel and {sup 187}W of the collimation system as well as positron emitters, activated via (n,γ) and (γ,n) processes, respectively. In addition to 12 Gy of therapeutic dose, the patient could receive 57.43 mSv in the studied conditions, including 4.63 μSv from activated radionuclides. Neutron dose is mainly influenced by the time of beam emission. However, it is moderated by long source-surface distances (SSD) and application of plexiglass plates covering the patient body during treatment. Secondary radiation gives the whole body a dose, which should be taken into consideration especially when one fraction of irradiation does not cover the whole body at once. (orig.) [German] Die zusaetzliche Dosis durch sekundaere Neutronen- und γ-Strahlung waehrend der Ganzkoerperbestrahlung mit Roentgenstrahlung aus medizinischen Linearbeschleunigern wurde abgeschaetzt. Bei der Emission hochenergetischer Strahlen zur Teletherapie finden hauptsaechlich im Beschleuniger

  9. Responses of Juvenile Black-Tailed Prairie Dogs ( Cynomys ludovicianus ) to a Commercially Produced Oral Plague Vaccine Delivered at Two Doses.

    Science.gov (United States)

    Cárdenas-Canales, Elsa M; Wolfe, Lisa L; Tripp, Daniel W; Rocke, Tonie E; Abbott, Rachel C; Miller, Michael W

    2017-05-02

    We confirmed safety and immunogenicity of mass-produced vaccine baits carrying an experimental, commercial-source plague vaccine (RCN-F1/V307) expressing Yersinia pestis V and F1 antigens. Forty-five juvenile black-tailed prairie dogs ( Cynomys ludovicianus ) were randomly divided into three treatment groups (n=15 animals/group). Animals in the first group received one standard-dose vaccine bait (5×10(7) plaque-forming units [pfu]; STD). The second group received a lower-dose bait (1×10(7) pfu; LOW). In the third group, five animals received two standard-dose baits and 10 were left untreated but in contact. Two vaccine-treated and one untreated prairie dogs died during the study, but laboratory analyses ruled out vaccine involvement. Overall, 17 of 33 (52%; 95% confidence interval for binomial proportion [bCI] 34-69%) prairie dogs receiving vaccine-laden bait showed a positive anti-V antibody response on at least one sampling occasion after bait consumption, and eight (24%; bCI 11-42%) showed sustained antibody responses. The STD and LOW groups did not differ (P≥0.78) in their proportions of overall or sustained antibody responses after vaccine bait consumption. Serum from one of the nine (11%; bCI 0.3-48%) surviving untreated, in-contact prairie dogs also had detectable antibody on one sampling occasion. We did not observe any adverse effects related to oral vaccination.

  10. Responses of juvenile black-tailed prairie dogs (Cynomys ludovicianus) to a commercially produced oral plague vaccine delivered at two doses

    Science.gov (United States)

    Cárdenas-Canales, Elsa M.; Wolfe, Lisa L.; Tripp. Daniel W.,; Rocke, Tonie E.; Abbott, Rachel C.; Miller, Michael W.

    2017-01-01

    We confirmed safety and immunogenicity of mass-produced vaccine baits carrying an experimental, commercial-source plague vaccine (RCN-F1/V307) expressing Yersinia pestis V and F1 antigens. Forty-five juvenile black-tailed prairie dogs (Cynomys ludovicianus) were randomly divided into three treatment groups (n=15 animals/group). Animals in the first group received one standard-dose vaccine bait (5×107 plaque-forming units [pfu]; STD). The second group received a lower-dose bait (1×107 pfu; LOW). In the third group, five animals received two standard-dose baits and 10 were left untreated but in contact. Two vaccine-treated and one untreated prairie dogs died during the study, but laboratory analyses ruled out vaccine involvement. Overall, 17 of 33 (52%; 95% confidence interval for binomial proportion [bCI] 34−69%) prairie dogs receiving vaccine-laden bait showed a positive anti-V antibody response on at least one sampling occasion after bait consumption, and eight (24%; bCI 11–42%) showed sustained antibody responses. The STD and LOW groups did not differ (P≥0.78) in their proportions of overall or sustained antibody responses after vaccine bait consumption. Serum from one of the nine (11%; bCI 0.3–48%) surviving untreated, in-contact prairie dogs also had detectable antibody on one sampling occasion. We did not observe any adverse effects related to oral vaccination.

  11. SU-E-P-55: The Reaserch of Cervical Cancer Delivered with Constant Dose Rate and Gantry Speed Arc Therapy(CDR-CAS-IMAT) On Conventional Linac

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, R; Bai, W; Chi, Z; Gao, C; Xiaomei, F [The Fourth Hospital of Hebei Medical University, Shijiazhuang, Hebei (China); Gao, Y [Hebei General Hospital, Shijiazhuang, Hebei (China)

    2015-06-15

    Purpose: Postoperative cervical cancer patients with large target volume and the target shape is concave, treatmented with static intensity-modulated radiotherapy (IMRT) is time consuming. The purpose of this study is to investigate using constant dose rate and gantry speed arc therapy(CDR-CAS-IMAT) on conventional linear accelrator, by comparing with the IMRT technology to evaluate the performance of CDR-CAS-IMAT on postoperative cervical cancer patients. Methods: 18 cervical cancer patients treated with IMRT on Varian 23IX were replanted using CDR-CAS-IMAT. The plans were generated on Oncentra v4.1 planning system, PTV was prescribed to 50.4 Gy in 28 fractions. Plans were evaluated based on the ability to meet the dose volume histogram. The homogeneity index (HI), conformity index (CI) of target volume, the dose of organs at risk, radiation delivery time and monitor units were also compared. SPSS 19.0 software paired T-test analysis was carried out on the two sets of data. Results: Compared with the IMRT plans PTV’s CI (t= 3.85, P =0.001), CTV’s CI, HI, D90, D95, D98, V95, V98, V100 (t=4.21, −3.18, 2.13, 4.65, 7.79, 2.29, 6.00, 2.13, p=0.001, 0.005, 0.049, 0.000, 0.000, 0.035, 0.000, 0.049), and cord D2 and rectum V40 (t=−2.65, −2.47, p= P =0.017, 0.025), and treatment time and MU (t=−36.0, −6.26, P =0.000, 0.000) were better than that of IMRT group. But the IMRT plans in terms of decreasing bladder V50, bowel V30 (t=2.14, 3.00, P =0.048, 0.008) and low dose irradiation volume were superior to that of CDR-CAS-IMAT plans. There were no significant differences in other statistical index. Conclusion: Cervical cancer patients with CDR-CAS-IMAT on Varian Clinical 23IX can get equivalent or superior dose distribution compared with the IMRT technology. IMAT have much less treatment time and MU can reduce the uncertainty factor and patient discomfort in treatment. This work was supported by the Medical Science Foundation of the health department of Hebei

  12. High-dose vs low-dose proton pump inhibitors for upper gastrointestinal bleeding: a meta-analysis.

    Science.gov (United States)

    Wu, Liu-Cheng; Cao, Yun-Fei; Huang, Jia-Hao; Liao, Cun; Gao, Feng

    2010-05-28

    To evaluate the efficacy of high-dose proton pump inhibitors (PPIs) vs low-dose PPIs for patients with upper gastrointestinal bleeding. PubMed, Embase, the Cochrane Library, and Web of Science were searched to identify relevant randomized controlled trials (RCTs). Eligible trials were RCTs that compared high-dose PPI with low-dose PPI following endoscopic hemostasis. The primary endpoint was rebleeding; secondary endpoints were patient numbers that needed surgery, and mortality. The meta-analysis was performed with a fixed effects model or random effects model. Nine eligible RCTs including 1342 patients were retrieved. The results showed that high-dose intravenous PPI was not superior to low-dose intravenous PPI in reducing rebleeding [odds ratio (OR) = 1.091, 95% confidential interval (CI): 0.777-1.532], need for surgery (OR = 1.522, 95% CI: 0.643-3.605) and mortality (OR = 1.022, 95% CI: 0.476-2.196). Subgroup analysis according to different region revealed no difference in rebleeding rate between Asian patients (OR = 0.831, 95% CI, 0.467-1.480) and European patients (OR = 1.263, 95% CI: 0.827-1.929). Low-dose intravenous PPI can achieve the same efficacy as high-dose PPI following endoscopic hemostasis.

  13. Dose optimization of intra-operative high dose rate interstitial brachytherapy implants for soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Jamema Swamidas

    2009-01-01

    Full Text Available Objective : A three dimensional (3D image-based dosimetric study to quantitatively compare geometric vs. dose-point optimization in combination with graphical optimization for interstitial brachytherapy of soft tissue sarcoma (STS. Materials and Methods : Fifteen consecutive STS patients, treated with intra-operative, interstitial Brachytherapy, were enrolled in this dosimetric study. Treatment plans were generated using dose points situated at the "central plane between the catheters", "between the catheters throughout the implanted volume", at "distances perpendicular to the implant axis" and "on the surface of the target volume" Geometrically optimized plans had dose points defined between the catheters, while dose-point optimized plans had dose points defined at a plane perpendicular to the implant axis and on the target surface. Each plan was graphically optimized and compared using dose volume indices. Results : Target coverage was suboptimal with coverage index (CI = 0.67 when dose points were defined at the central plane while it was superior when the dose points were defined at the target surface (CI=0.93. The coverage of graphically optimized plans (GrO was similar to non-GrO with dose points defined on surface or perpendicular to the implant axis. A similar pattern was noticed with conformity index (0.61 vs. 0.82. GrO were more conformal and less homogeneous compared to non-GrO. Sum index was superior for dose points defined on the surface of the target and relatively inferior for plans with dose points at other locations (1.35 vs. 1.27. Conclusions : Optimization with dose points defined away from the implant plane and on target results in superior target coverage with optimal values of other indices. GrO offer better target coverage for implants with non-uniform geometry and target volume.

  14. Adaptive planning strategy for high dose rate prostate brachytherapy—a simulation study on needle positioning errors.

    Science.gov (United States)

    Borot de Battisti, M; Denis de Senneville, B; Maenhout, M; Hautvast, G; Binnekamp, D; Lagendijk, J J W; van Vulpen, M; Moerland, M A

    2016-03-01

    The development of magnetic resonance (MR) guided high dose rate (HDR) brachytherapy for prostate cancer has gained increasing interest for delivering a high tumor dose safely in a single fraction. To support needle placement in the limited workspace inside the closed-bore MRI, a single-needle MR-compatible robot is currently under development at the University Medical Center Utrecht (UMCU). This robotic device taps the needle in a divergent way from a single rotation point into the prostate. With this setup, it is warranted to deliver the irradiation dose by successive insertions of the needle. Although robot-assisted needle placement is expected to be more accurate than manual template-guided insertion, needle positioning errors may occur and are likely to modify the pre-planned dose distribution.In this paper, we propose a dose plan adaptation strategy for HDR prostate brachytherapy with feedback on the needle position: a dose plan is made at the beginning of the interventional procedure and updated after each needle insertion in order to compensate for possible needle positioning errors. The introduced procedure can be used with the single needle MR-compatible robot developed at the UMCU. The proposed feedback strategy was tested by simulating complete HDR procedures with and without feedback on eight patients with different numbers of needle insertions (varying from 4 to 12). In of the cases tested, the number of clinically acceptable plans obtained at the end of the procedure was larger with feedback compared to the situation without feedback. Furthermore, the computation time of the feedback between each insertion was below 100 s which makes it eligible for intra-operative use.

  15. Impact of high dose vitamin C on platelet function

    Science.gov (United States)

    Mohammed, Bassem M; Sanford, Kimberly W; Fisher, Bernard J; Martin, Erika J; Contaifer Jr, Daniel; Warncke, Urszula Osinska; Wijesinghe, Dayanjan S; Chalfant, Charles E; Brophy, Donald F; Fowler III, Alpha A; Natarajan, Ramesh

    2017-01-01

    AIM To examine the effect of high doses of vitamin C (VitC) on ex vivo human platelets (PLTs). METHODS Platelet concentrates collected for therapeutic or prophylactic transfusions were exposed to: (1) normal saline (control); (2) 0.3 mmol/L VitC (Lo VitC); or (3) 3 mmol/L VitC (Hi VitC, final concentrations) and stored appropriately. The VitC additive was preservative-free buffered ascorbic acid in water, pH 5.5 to 7.0, adjusted with sodium bicarbonate and sodium hydroxide. The doses of VitC used here correspond to plasma VitC levels reported in recently completed clinical trials. Prior to supplementation, a baseline sample was collected for analysis. PLTs were sampled again on days 2, 5 and 8 and assayed for changes in PLT function by: Thromboelastography (TEG), for changes in viscoelastic properties; aggregometry, for PLT aggregation and adenosine triphosphate (ATP) secretion in response to collagen or adenosine diphosphate (ADP); and flow cytometry, for changes in expression of CD-31, CD41a, CD62p and CD63. In addition, PLT intracellular VitC content was measured using a fluorimetric assay for ascorbic acid and PLT poor plasma was used for plasma coagulation tests [prothrombin time (PT), partial thrombplastin time (PTT), functional fibrinogen] and Lipidomics analysis (UPLC ESI-MS/MS). RESULTS VitC supplementation significantly increased PLTs intracellular ascorbic acid levels from 1.2 mmol/L at baseline to 3.2 mmol/L (Lo VitC) and 15.7 mmol/L (Hi VitC, P 8 d exposure period (P > 0.05). PLT function assayed by TEG, aggregometry and flow cytometry was not significantly altered by Lo or Hi VitC for up to 5 d. However, PLTs exposed to 3 mmol/L VitC for 8 d demonstrated significantly increased R and K times by TEG and a decrease in the α-angle (P 0.05). Collagen and ADP-induced ATP secretion was also not different between the three groups (P > 0.05). Finally, VitC at the higher dose (3 mmol/L) also induced the release of several eicosanoids including thromboxane B2

  16. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.

    Science.gov (United States)

    Chibani, Omar; Ma, Chang-Ming Charlie

    2003-08-01

    The dose from photon-induced nuclear particles (neutrons, protons, and alpha particles) generated by high-energy photon beams from medical linacs is investigated. Monte Carlo calculations using the MCNPX code are performed for three different photon beams from two different machines: Siemens 18 MV, Varian 15 MV, and Varian 18 MV. The linac head components are simulated in detail. The dose distributions from photons, neutrons, protons, and alpha particles are calculated in a tissue-equivalent phantom. Neutrons are generated in both the linac head and the phantom. This study includes (a) field size effects, (b) off-axis dose profiles, (c) neutron contribution from the linac head, (d) dose contribution from capture gamma rays, (e) phantom heterogeneity effects, and (f) effects of primary electron energy shift. Results are presented in terms of absolute dose distributions and also in terms of DER (dose equivalent ratio). The DER is the maximum dose from the particle (neutron, proton, or alpha) divided by the maximum photon dose, multiplied by the particle quality factor and the modulation scaling factor. The total DER including neutrons, protons, and alphas is about 0.66 cSv/Gy for the Siemens 18 MV beam (10 cm x 10 cm). The neutron DER decreases with decreasing field size while the proton (or alpha) DER does not vary significantly except for the 1 cm x 1 cm field. Both Varian beams (15 and 18 MV) produce more neutrons, protons, and alphas particles than the Siemens 18 MV beam. This is mainly due to their higher primary electron energies: 15 and 18.3 MeV, respectively, vs 14 MeV for the Siemens 18 MV beam. For all beams, neutrons contribute more than 75% of the total DER, except for the 1 cm x 1 cm field (approximately 50%). The total DER is 1.52 and 2.86 cSv/Gy for the 15 and 18 MV Varian beams (10 cm x 10 cm), respectively. Media with relatively high-Z elements like bone may increase the dose from heavy charged particles by a factor 4. The total DER is sensitive to

  17. Study of radiation effects on the cell structure and evaluation of the dose delivered by x-ray and {alpha}-particles microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kosior, Ewelina; Cloetens, Peter [European Synchrotron Radiation Facility, F-38000 Grenoble (France); Deves, Guillaume; Ortega, Richard [Univ. Bordeaux, CENBG, UMR 5797, F-33170 Gradignan (France); CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Bohic, Sylvain [European Synchrotron Radiation Facility, 38000 Grenoble (France); INSERM U-836 (Team 6: Synchrotron Radiation and Medical Research), Grenoble Institut of Neuroscience, F-38000 Grenoble (France)

    2012-12-24

    Hard X-ray fluorescence microscopy and magnified phase contrast imaging are combined to study radiation effects on cells. Experiments were performed on freeze-dried cells at the nano-imaging station ID22NI of the European synchrotron radiation facility. Quantitative phase contrast imaging provides maps of the projected mass and is used to evaluate the structural changes due to irradiation during X-ray fluorescence experiments. Complementary to phase contrast imaging, scanning transmission ion microscopy is performed and doses of all the experiments are compared. We demonstrate the sensitivity of the proposed approach to study radiation-induced damage at the sub-cellular level.

  18. TH-C-BRD-08: Reducing the Effect of Respiratory Motion On the Delivered Dose in Proton Therapy Through Proper Field Angle Selection

    Energy Technology Data Exchange (ETDEWEB)

    Matney, J [UNC Health Care, Chapel Hill, NC (United States); Park, P [Emory University, Atlanta, GA (United States); Court, L; Zhu, X; Li, H; Mohan, R [UT MD Anderson Cancer Center, Houston, TX (United States); Liu, W [Mayo Clinic Arizona, Phoenix, AZ (United States); Dong, L [Scripps Proton Therapy Center, San Diego, CA (United States)

    2014-06-15

    Purpose: This work investigated a novel planning strategy of selecting radiotherapy beam angles that minimizes the change in water equivalent thickness (dWET) during respiration in order to reduce the effects of respiratory motion in passively scattered proton therapy (PSPT). Methods: In a clinical trial treating locally-advanced lung cancer with proton therapy, 2–4 co-planar beams were previously selected by dosimetrists in the design of physician-approved PSPT treatment plans. The authors identified a cohort of patients in which respiratory motion affected the planned PSPT dose delivery. For this cohort, this work analyzed dWET during respiration over a 360 degree arc of potential treatment angles around the patient: the dWET was defined as the difference in WET between the full-exhale (T50) and full-inhale (T0) phases of the simulation 4DCT. New PSPT plans were redesigned by selecting new beam angles that demonstrated significant reduction in the value of dWET. Between the T50 and T0 phases, the root-mean-square deviation of dose and the change in dose-volume histogram curves (dAUC) for anatomical structures were calculated to compare the original to dWET reduction plans. Results: To date, three plans were retrospectively redesigned based on dWET analysis. In the dWET reduction plan, the root mean square dose (T50-T0) was reduced by 15–35% and the DVH dAUC values were reduced by more than 60%.The PSPT plans redesigned by selecting appropriate field angles to minimize dWET demonstrated less dosimetric variation due to respiration. Conclusion: We have introduced the use of a new metric to quantify respiratory motion in proton therapy: dWET. The use of dWET allows us to minimize the impact of respiratory motion of the entire anatomy in the beam path. This work is a proof of principle that dWET could suggest field angles in proton therapy that are more robust to the effects of respiratory motion.

  19. Dendritic silica nanomaterials (KCC-1) with fibrous pore structure possess high DNA adsorption capacity and effectively deliver genes in vitro.

    Science.gov (United States)

    Huang, Xiaoxi; Tao, Zhimin; Praskavich, John C; Goswami, Anandarup; Al-Sharab, Jafar F; Minko, Tamara; Polshettiwar, Vivek; Asefa, Tewodros

    2014-09-16

    The pore size and pore structure of nanoporous materials can affect the materials' physical properties, as well as potential applications in different areas, including catalysis, drug delivery, and biomolecular therapeutics. KCC-1, one of the newest members of silica nanomaterials, possesses fibrous, large pore, dendritic pore networks with wide pore entrances, large pore size distribution, spacious pore volume and large surface area--structural features that are conducive for adsorption and release of large guest molecules and biomacromolecules (e.g., proteins and DNAs). Here, we report the results of our comparative studies of adsorption of salmon DNA in a series of KCC-1-based nanomaterials that are functionalized with different organoamine groups on different parts of their surfaces (channel walls, external surfaces or both). For comparison the results of our studies of adsorption of salmon DNA in similarly functionalized, MCM-41 mesoporous silica nanomaterials with cylindrical pores, some of the most studied silica nanomaterials for drug/gene delivery, are also included. Our results indicate that, despite their relatively lower specific surface area, the KCC-1-based nanomaterials show high adsorption capacity for DNA than the corresponding MCM-41-based nanomaterials, most likely because of KCC-1's large pores, wide pore mouths, fibrous pore network, and thereby more accessible and amenable structure for DNA molecules to diffuse through. Conversely, the MCM-41-based nanomaterials adsorb much less DNA, presumably because their outer surfaces/cylindrical channel pore entrances can get blocked by the DNA molecules, making the inner parts of the materials inaccessible. Moreover, experiments involving fluorescent dye-tagged DNAs suggest that the amine-grafted KCC-1 materials are better suited for delivering the DNAs adsorbed on their surfaces into cellular environments than their MCM-41 counterparts. Finally, cellular toxicity tests show that the KCC-1-based

  20. Long-term Tesio catheter access for hemodialysis can deliver high dialysis adequacy with low complication rates.

    Science.gov (United States)

    Power, Albert; Singh, Seema K; Ashby, Damien; Cairns, Tom; Taube, David; Duncan, Neill

    2011-05-01

    The use of central venous catheters for long-term hemodialysis has been associated with increased mortality and high prevalence of infection and venous stenosis. However, because central venous catheters still constitute a significant proportion of vascular access in prevalent populations, even in the Fistula-First era, the authors examined the long-term patient outcomes and performance of this vascular access type to inform current clinical practice. The authors conducted a retrospective cohort study of 433 patients on maintenance hemodialysis in a dialysis program from January 1999 through April 2008 all using twin-catheter Tesio Caths (TCs) (MedCOMP, Harleysville, Pennsylvania). Written and electronic records were examined with respect to laboratory indices as well as mortality, access-related infection, need for thrombolytic infusion, access revision and dialysis adequacy. A total of 759 TCs were inserted with 552,035 catheter days follow-up. Thirty-six percent of insertions were in patients incident to dialysis (Catheter-related bacteremia occurred at a rate of 0.34 per 1,000 catheter days. Appropriate use of TCs with protocolized care can deliver effective long-term hemodialysis with good adequacy and rates of access-related infection approaching those seen with arteriovenous grafts. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  1. SU-E-T-383: Can Stereotactic Body Radiotherapy Mimic the Dose Distribution of High-Dose-Rate Tandem and Ovoids/ring Brachytherapy?

    Energy Technology Data Exchange (ETDEWEB)

    Park, S; Demanes, J; Kamrava, M [UCLA School of Medicine, Los Angeles, CA (United States); Scanderbeg, D [UCSD Medical Center, La Jolla, CA (United States)

    2014-06-01

    Purpose: To investigate whether stereotactic body radiotherapy (SBRT) using volumetric modulated arc therapy (VMAT) can mimic the dosimetry of tandem and ovoids/ring brachytherapy. Methods: We selected 5 patients treated with 3D-CT based high-dose rate (HDR) brachytherapy using 4 tandem and ovoid and 1 tandem and ring case. Manual optimization based on the Manchester system followed by graphical optimization (Nucletron Oncentra MasterPlan or Varian BrachyVision) was performed to deliver 6.0 Gy per fraction to a high-risk CTV while maintaining dose to organs at risk (OAR) below the ABS recommendations. For theoretical SBRT plans, CT images and OAR contours from the HDR plans were imported into Eclipse (Varian). The SBRT plan was created to mimic the heterogeneity of HDR plans by using a simultaneous integrated boost technique to match the V100, V150, and V200 isodose volumes from HDR. The OAR Dmax from HDR was used to define the OAR dose constraints for SBRT. Target coverage, dose spill-out, and OAR doses (D0.1cc, D1cc, and D2cc) between the HDR and SBRT plans were compared for significance using a two-tail paired ttest. Results: The mean isodose volumes for HDR vs. SBRT were 29.4 cc vs. 29.0 cc (V200, p = 0.674), 49.2 cc vs. 56.3 cc (V150, p = 0.017), 95.4 cc vs. 127.7 cc (V100, p = 0.001), and 271.9 cc vs. 581.6 cc (V50, p = 0.001). The D2cc to OAR for HDR vs. SBRT was 71.6% vs. 96.2% (bladder, p = 0.002), 69.2% vs. 101.7% (rectum, p = 0.0003), and 56.9% vs. 68.6% (sigmoid, p = 0.004). Conclusion: SBRT with VMAT can provide similar dose target coverage (V200), but dose spill-out and doses to OAR were statistically significantly higher than HDR. This study clearly demonstrated that brachytherapy can not be substituted with SBRT in gynecologic cervical cancer treatment.

  2. Shelf-stable food through high dose irradiation

    Science.gov (United States)

    Plaček, V.; Svobodová, V.; Bartoníček, B.; Rosmus, J.; Čamra, M.

    2004-09-01

    Irradiation of food with high doses (radappertization) is a way, how to prepare shelf-stable ready-to-eat food. The radappertization process requires that the food be heated at first to an internal temperature of at least 75°C to inactivate autolytic enzyme, which could cause the spoilage during storage without refrigeration. In order to prevent radiation induced changes in sensory properties (off flavors, odors, undesirable color change, etc.) the food was vacuum packed and irradiated in frozen state at -30°C or less to a minimum dose of 35 kGy. Such products have characteristics of fresh food prepared for eating even if they are stored for long time under tropical conditions. The wholesomeness (safety for consumption) has been confirmed during 40 years of testing. Within the NRI Řež 10 kinds of shelf-stable meat products have been prepared. The meat was cooked, vacuum packed in SiO x-containing pouch, freezed in liquid nitrogen and irradiated with electron beam accelerator. The microbial, chemical, and organoleptic properties have been tested.

  3. Shelf-stable food through high dose irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Placek, V. E-mail: pla@ujv.cz; Svobodova, V.; Bartonicek, B.; Rosmus, J.; Camra, M

    2004-10-01

    Irradiation of food with high doses (radappertization) is a way, how to prepare shelf-stable ready-to-eat food. The radappertization process requires that the food be heated at first to an internal temperature of at least 75 deg. C to inactivate autolytic enzyme, which could cause the spoilage during storage without refrigeration. In order to prevent radiation induced changes in sensory properties (off flavors, odors, undesirable color change, etc.) the food was vacuum packed and irradiated in frozen state at -30 deg. C or less to a minimum dose of 35 kGy. Such products have characteristics of fresh food prepared for eating even if they are stored for long time under tropical conditions. The wholesomeness (safety for consumption) has been confirmed during 40 years of testing. Within the NRI Rez 10 kinds of shelf-stable meat products have been prepared. The meat was cooked, vacuum packed in SiO{sub x}-containing pouch, freezed in liquid nitrogen and irradiated with electron beam accelerator. The microbial, chemical, and organoleptic properties have been tested.

  4. High-dose processing and application to Korean space foods

    Science.gov (United States)

    Song, Beom-Seok; Park, Jin-Gyu; Park, Jae-Nam; Han, In-Jun; Choi, Jong-il; Kim, Jae-Hun; Byun, Myung-Woo; Kang, Sang-Wook; Choi, Gi-Hyuk; Lee, Ju-Woon

    2009-07-01

    Nutrition bar, Ramen (ready-to-cook noodle), and two Korean traditional foods ( Kimchi, fermented vegetable; Sujeonggwa, cinnamon beverage) have been developed as space foods using high-dose gamma irradiation. Addition of calcium lactate and vitamin C, a mild heating, deep-freezing, and gamma irradiation at 25 kGy were conducted to prepare Kimchi as a ready-to-eat space food. Sterilization of Space Kimchi (SK) was confirmed by a microbiological test. The hardness of the Space Kimchi was lower than the untreated Kimchi (CON), but higher than the irradiated only Kimchi. Sensory attributes of the SK were similar to CON, and maintained during preservation at 35 °C for 30 days. The optimal doses for eliminating the contaminated microbes and maintaining the qualities of the Nutrition bars, Ramen, and Sujeonggwa were determined at 15, 10 and 6 kGy, respectively. All the Korean space food were certificated for use in space flight conditions of 30 days by the Russian Institute for Biomedical Problems.

  5. Characterization of a silicate glass as a high dose dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Farah, K., E-mail: k.farah@cnstn.rnrt.t [Laboratoire de Radiotraitement. Centre National des Sciences et Technologie Nucleaires, 2020 Sidi-Thabet (Tunisia); Mejri, A.; Hosni, F. [Laboratoire de Radiotraitement. Centre National des Sciences et Technologie Nucleaires, 2020 Sidi-Thabet (Tunisia); Ben Ouada, H. [Laboratoire de Physique et Chimie des Interfaces, Faculte des Sciences de Monastir, 5000 Monastir (Tunisia); Fuochi, P.G.; Lavalle, M. [ISOF-CNR, Via P. Gobetti 101, 40129 Bologna (Italy); Kovacs, A. [Institute of Isotopes, HAS, P.O. Box 77, H-1525 Budapest (Hungary)

    2010-02-21

    Commercial silicate glass has been investigated as a possible high dose dosimeter using an UV-vis spectrophotometer. Glass samples were irradiated by {sup 60}Co gamma rays and the results compared with those obtained with 3.4 and 8.4 MeV electron beams. The irradiated samples showed rapid fading at room temperature immediately after irradiation. In order to improve the stability of absorbance, glass samples were submitted to post-irradiation thermal treatments (150 deg. C for 20 min). The influences of the dose, type and energy of the ionizing radiation on the fading characteristics and on the response of the irradiated and thermally treated glasses were studied. Dependence of the glass response on the temperature during gamma irradiation in the range -3 to 80 deg. C is reported. The reproducibility to reuse glass dosimeter by thermal bleaching the radiation induced colour centres at 300 deg. C for 30 min was also investigated. Calibration curves in the range 0.1-17 kGy were obtained by using in-plant calibration techniques against transfer standard alanine dosimeters in the Tunisian semi-industrial gamma irradiation facility.

  6. High-dose processing and application to Korean space foods

    Energy Technology Data Exchange (ETDEWEB)

    Song, Beom-Seok; Park, Jin-Gyu; Park, Jae-Nam; Han, In-Jun; Choi, Jong-il [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Kim, Jae-Hun [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Korea Astronaut Project Division, Korea Aerospace Research Institute, Daejeon 305-333 (Korea, Republic of); Byun, Myung-Woo [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Kang, Sang-Wook; Choi, Gi-Hyuk [Korea Astronaut Project Division, Korea Aerospace Research Institute, Daejeon 305-333 (Korea, Republic of); Lee, Ju-Woon [Team for Radiation Food Science and Biotechnology, Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of)], E-mail: sjwlee@kaeri.re.kr

    2009-07-15

    Nutrition bar, Ramen (ready-to-cook noodle), and two Korean traditional foods (Kimchi, fermented vegetable; Sujeonggwa, cinnamon beverage) have been developed as space foods using high-dose gamma irradiation. Addition of calcium lactate and vitamin C, a mild heating, deep-freezing, and gamma irradiation at 25 kGy were conducted to prepare Kimchi as a ready-to-eat space food. Sterilization of Space Kimchi (SK) was confirmed by a microbiological test. The hardness of the Space Kimchi was lower than the untreated Kimchi (CON), but higher than the irradiated only Kimchi. Sensory attributes of the SK were similar to CON, and maintained during preservation at 35 {sup o}C for 30 days. The optimal doses for eliminating the contaminated microbes and maintaining the qualities of the Nutrition bars, Ramen, and Sujeonggwa were determined at 15, 10 and 6 kGy, respectively. All the Korean space food were certificated for use in space flight conditions of 30 days by the Russian Institute for Biomedical Problems.

  7. High-dose neutron irradiation embrittlement of RAFM steels

    Energy Technology Data Exchange (ETDEWEB)

    Gaganidze, E. [Forschungszentrum Karlsruhe, Institut fuer Materialforschung II, P.O. Box 3640, 76021 Karlsruhe (Germany)]. E-mail: ermile.gaganidze@imf.fzk.de; Schneider, H.-C. [Forschungszentrum Karlsruhe, Institut fuer Materialforschung II, P.O. Box 3640, 76021 Karlsruhe (Germany); Dafferner, B. [Forschungszentrum Karlsruhe, Institut fuer Materialforschung II, P.O. Box 3640, 76021 Karlsruhe (Germany); Aktaa, J. [Forschungszentrum Karlsruhe, Institut fuer Materialforschung II, P.O. Box 3640, 76021 Karlsruhe (Germany)

    2006-09-01

    Neutron irradiation-induced embrittlement of the reduced-activation ferritic/martensitic (RAFM) steel EUROFER97 was studied under different heat treatment conditions. Irradiation was performed in the Petten High Flux Reactor within the HFR Phase-IIb (SPICE) irradiation project up to 16.3 dpa and at different irradiation temperatures (250-450 deg. C). Several reference RAFM steels (F82H-mod, OPTIFER-Ia, GA3X and MANET-I) were also irradiated at selected temperatures. The impact properties were investigated by instrumented Charpy-V tests with subsize specimens. Embrittlement and hardening of as-delivered EUROFER97 steel are comparable to those of reference steels. Heat treatment of EUROFER97 at a higher austenitizing temperature substantially improves the embrittlement behaviour at low irradiation temperatures. Analysis of embrittlement in terms of the parameter C = {delta}DBTT/{delta}{sigma} indicates hardening-dominated embrittlement at irradiation temperatures below 350 deg. C with 0.17 {<=} C {<=} 0.53 deg. C/MPa. Scattering of C at irradiation temperatures above 400 deg. C indicates no hardening embrittlement.

  8. High-dose neutron irradiation embrittlement of RAFM steels

    Science.gov (United States)

    Gaganidze, E.; Schneider, H.-C.; Dafferner, B.; Aktaa, J.

    2006-09-01

    Neutron irradiation-induced embrittlement of the reduced-activation ferritic/martensitic (RAFM) steel EUROFER97 was studied under different heat treatment conditions. Irradiation was performed in the Petten High Flux Reactor within the HFR Phase-IIb (SPICE) irradiation project up to 16.3 dpa and at different irradiation temperatures (250-450 °C). Several reference RAFM steels (F82H-mod, OPTIFER-Ia, GA3X and MANET-I) were also irradiated at selected temperatures. The impact properties were investigated by instrumented Charpy-V tests with subsize specimens. Embrittlement and hardening of as-delivered EUROFER97 steel are comparable to those of reference steels. Heat treatment of EUROFER97 at a higher austenitizing temperature substantially improves the embrittlement behaviour at low irradiation temperatures. Analysis of embrittlement in terms of the parameter C = ΔDBTT/Δ σ indicates hardening-dominated embrittlement at irradiation temperatures below 350 °C with 0.17 ⩽ C ⩽ 0.53 °C/MPa. Scattering of C at irradiation temperatures above 400 °C indicates no hardening embrittlement.

  9. Do weight management programmes delivered at professional football clubs attract and engage high risk men? A mixed-methods study.

    Science.gov (United States)

    Hunt, Kate; Gray, Cindy M; Maclean, Alice; Smillie, Susan; Bunn, Christopher; Wyke, Sally

    2014-01-21

    The prevalence of obesity in men in the UK is amongst the highest in Europe but men are less likely than women to use existing weight loss programmes. Developing weight management programmes which are appealing and acceptable to men is a public health priority. Football Fans in Training (FFIT), a men-only weight management programme delivered to groups of men at top professional football clubs, encourages men to lose weight by working with, not against, cultural ideals of masculinity. To inform further development of interventions in football club settings, the current study explored who is attracted to FFIT and why overweight/obese men choose to take part. A mixed-methods study analysing baseline data on 747 men aged 35-65 years with BMI ≥ 28 kg/m2 who were participants in a randomised controlled trial of FFIT, and data from 13 focus group discussions with 63 men who had attended the programme. Objectively-measured mean body mass index was 35.3 kg/m2 (sd 4.9). Overall over 90% of participants were at very high or extremely high risk of future ill-health. Around three-quarters of participants in all age groups were at 'very high' risk of type 2 diabetes, hypertension and cardiovascular disease (72%, 73% and 80% of men aged 35-44, 45-54 and 55-64 years respectively). A further 21%, 16% and 13% were at 'extremely high' risk. Qualitative data revealed that the powerful 'draw' of the football club attracted men otherwise reluctant to attend existing weight management programmes. The location and style of delivery of early FFIT sessions fostered team spirit; men appreciated being with others 'like them' and the opportunity to undertake weight management in circumstances that enhanced physical and symbolic proximity to something they valued highly, the football club. The delivery of a weight management intervention via professional football clubs attracted men at high risk of ill-health. The setting enabled men to join a weight management programme in

  10. Teflon pastille use in high dose dosimetry; Utilizacao de pastilhas de teflon em dosimetria de doses altas

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Maria Ines [Associacao Educacional Nove de Julho (UNINOVE), Sao Paulo, SP (Brazil); Caldas, Linda V.E., E-mail: miteixeira@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    This paper study the Teflon, which is used as aglomerant in the confection of dosimetric pastilles, for the viabilization of this material as high dose dosimeter. This paper used the OSL technique for the characterization of dosimetric properties of Teflon. The doses-response curve has been obtained for {sup 60}Co radiation between 100 Gy and 50 kGy, and the OSL answer reproducibility. The preliminary results shown that the Teflon is a material which can be used for high dose dosimetry

  11. Five-Year Outcomes of High-Dose Single-Fraction Spinal Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Moussazadeh, Nelson [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Lis, Eric [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Katsoulakis, Evangelia [Department of Radiation Oncology, New York Methodist Hospital, Brooklyn, New York (United States); Kahn, Sweena; Svoboda, Marek; DiStefano, Natalie M.; McLaughlin, Lily [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Bilsky, Mark H. [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Yamada, Yoshiya [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Laufer, Ilya, E-mail: lauferi@mskcc.org [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States)

    2015-10-01

    Purpose: To characterize local tumor control and toxicity risk in very long-term survivors (>5 years) after high-dose spinal image guided, intensity modulated radiation therapy delivered as single-dose stereotactic radiosurgery (SRS). Previously published spinal SRS outcome analyses have included a heterogeneous population of cancer patients, mostly with short survival. This is the first study reporting the long-term tumor control and toxicity profiles after high-dose single-fraction spinal SRS. Methods and Materials: The study population included all patients treated from June 2004 to July 2009 with single-fraction spinal SRS (dose 24 Gy) who had survived at least 5 years after treatment. The endpoints examined included disease progression, surgical or radiation retreatment, in-field fracture development, and radiation-associated toxicity, scored using the Radiation Therapy Oncology Group radiation morbidity scoring criteria and the Common Terminology Criteria for Adverse Events, version 4.0. Local control and fracture development were assessed using Kaplan-Meier analysis. Results: Of 278 patients, 31 (11.1%), with 36 segments treated for spinal tumors, survived at least 5 years after treatment and were followed up radiographically and clinically for a median of 6.1 years (maximum 102 months). The histopathologic findings for the 5-year survivors included radiation-resistant metastases in 58%, radiation-sensitive metastases in 22%, and primary bone tumors in 19%. In this selected cohort, 3 treatment failures occurred at a median of 48.6 months, including 2 recurrences in the radiation field and 1 patient with demonstrated progression at the treatment margins. Ten lesions (27.8%) were associated with acute grade 1 cutaneous or gastrointestinal toxicity. Delayed toxicity ≥3 months after treatment included 8 cases (22.2%) of mild neuropathy, 2 (5.6%) of gastrointestinal discomfort, 8 (22.2%) of dermatitides, and 3 (8.3%) of myalgias/myositis. Thirteen

  12. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  13. Comparison of low-dose and high-dose cosyntropin stimulation testing in children.

    Science.gov (United States)

    Cemeroglu, Ayse Pinar; Kleis, Lora; Postellon, Daniel C; Wood, Michael A

    2011-04-01

      There is no consensus among pediatric endocrinologists in using low-dose (LD) versus high-dose (HD) cosyntropin to test for secondary/tertiary adrenal insufficiency. This paper compares LD and HD cosyntropin stimulation testing in children for evaluation of hypothalamic-pituitary-adrenal axis (HPAA) and suggests a new peak cortisol cut-off value for LD stimulation testing to avoid false positivity.   Data of 36 children receiving LD (1 µg) and HD (249 µg) cosyntropin consecutively during growth hormone (GH) stimulation testing were analyzed in two groups. Group A were patients who passed GH stimulation testing and were not on oral, inhaled or intranasal steroids (intact hypothalamic-pituitary axis, n= 19). Group B were patients who failed GH stimulation testing and/or were on oral, inhaled or intranasal steroids (impaired hypothalamic-pituitary axis, n= 17).   In group A, the mean peak cortisol response in LD cosyntropin was 18.5 ± 2.4 µg/dL and that for the HD cosyntropin was 24.8 ± 3.1 µg/dL (r: 0.76, P≤ 0.05). In group B, the mean peak cortisol response in LD cosyntropin was 15.7 ± 6.1 µg/dL and that for HD cosyntropin was 21.7 ± 7.9 µg/dL (r: 0.98, P≤ 0.05). When a standard cut-off of 18 µg/dL was used, 37% of the patients with intact HPAA failed LD cosyntropin testing, but a cut-off of 14 µg/dL eliminated false positive results.   LD cosyntropin stimulation testing results should be interpreted cautiously when used alone to prevent unnecessary long-term treatment. Using a lower cut-off for LD (≥14 µg/dL) seems to avoid false positive results and still detects most cases of impaired HPAA. © 2011 The Authors.Pediatrics International © 2011 Japan Pediatric Society.

  14. High-dose thiamine improves the symptoms of fibromyalgia.

    Science.gov (United States)

    Costantini, Antonio; Pala, Maria Immacolata; Tundo, Silvia; Matteucci, Pietro

    2013-05-20

    Living with fibromyalgia means living with chronic pain, fatigue, sleep disorders and other associated key symptoms. To date, pharmacotherapy generally produces modest benefits. Some observations indicate that the large majority of symptoms of fibromyalgia could be the clinical manifestation of a mild thiamine deficiency due to a dysfunction of the active transport of thiamine from the blood to the mitochondria or to enzymatic abnormalities. Between June and July 2011, we recruited three female patients affected by fibromyalgia. We proceeded with the study of the patients' history, a physical examination, an evaluation of chronic widespread pain using the Visual Numeric Scale and an evaluation of the fatigue using the Fatigue Severity Scale were also performed. The levels of thiamine and thiamine pyrophosphate in the blood were determined. After the therapy with high doses of thiamine, in the patients, there was an appreciable improvement of the symptoms.

  15. High-dose thiamine improves the symptoms of Friedreich's ataxia.

    Science.gov (United States)

    Costantini, Antonio; Giorgi, Rafaela; D'Agostino, Sonia; Pala, Maria Immacolata

    2013-05-22

    Friedreich's ataxia (FRDA) is an autosomal recessive inherited disorder characterised by progressive gait and limb ataxia, dysarthria, areflexia, loss of position sense and a progressive motor weakness of central origin. Some observations indicate that all symptoms of FRDA ataxia could be the manifestation of a thiamine deficiency because of enzymatic abnormalities. Two patients with FRDA were under rehabilitative treatment from February 2012 to February 2013. The scale for assessment and rating of ataxia was performed. The patient began an intramuscular therapy with 100 mg of thiamine every 3-5 days. Injection of high-dose thiamine was effective in reversing the motor failure. From this clinical observation, it is reasonable to infer that a thiamine deficiency due to enzymatic abnormalities could cause a selective neuronal damage in the centres that are typically affected by this disease.

  16. Pharmacokinetics of high-dose intravenous melatonin in humans

    DEFF Research Database (Denmark)

    Andersen, Lars P H; Werner, Mads U; Rosenkilde, Mette Marie

    2016-01-01

    This crossover study investigated the pharmacokinetics and adverse effects of high-dose intravenous melatonin. Volunteers participated in 3 identical study sessions, receiving an intravenous bolus of 10 mg melatonin, 100 mg melatonin, and placebo. Blood samples were collected at baseline and 0, 60......, 120, 180, 240, 300, 360, and 420 minutes after the bolus. Quantitative determination of plasma melatonin concentrations was performed using a radioimmunoassay technique. Pharmacokinetic parameters were estimated by a compartmental pharmacokinetic analysis. Adverse effects included assessments...... of sedation and registration of other symptoms. Sedation, evaluated as simple reaction times, was measured at baseline and 120, 180, 300, and 420 minutes after the bolus. Twelve male volunteers completed the study. Median (IQR) Cmax after the bolus injections of 10 mg and 100 mg of melatonin were 221...

  17. "Time sequential high dose of Cytarabine in acute myelocytic leukemia "

    Directory of Open Access Journals (Sweden)

    Ghavamzadeh A

    2003-05-01

    Full Text Available Given preliminary evidence of timed, sequential chemotherapy of high dose cytosine arabinoside the current study was initiated to assess the side effects and efficacy of this regimen in patients with newly acute myelocytic leukemia (AML. Nineteen adults who referred to Hematology-Oncology and Bone Marrow Transplantation (BMT research center of Tehran University of Medical Sciences were enrolled in a trial from Aug 1999 to Nov 2000. All patients had a Karnofski classification above 60%. At this time induction therapy consisted of daunorubicin or idarubicin given at a dose of 60 mg/m² and 12 mg/m² IV respectively on days 1-3, and cytarabine (Ara-C 100 mg/m² intravenously by continuous infusion on days 1-7, followed by Ara-C 1000 mg/m² given on day 8-10 every 12 hours by IV infusion. Consolidation therapy started after 35th day. Of 19 fully evaluable patients, 10 patients achieved a complete remission, whereas 36.6% patients succumbed to death due to regeneration failure. The clinical data show that the overall survival rate from diagnosis 55.5% (95% CI, 30.8-78.5 at 6 months for the entire cohort of the patients. Disease free survival is also 50% (95% CI, 26-74. Mean duration of death due to treatment was 20 days (range 17-29 after beginning the regimen. Presenting WBC counts, French-American-British (FAB classification, sex and age were not useful prognostic variables. Fever, diarrhea, nausea and vomiting and GI hemorrhage were seen in 19, 6, 4, 7 patients respectively. It seems the 3+7+3 regimen is a promising approach for the AML patients regarding to high complete remission rate, but more supportive care should be considered. Furthermore any, benefit in long-term outcome can’t be determined regardless to the choice of post remission therapy (e.g., GCSF, appropriate antibiotics and etc.

  18. High-Dose Vitamin D Failed to Curb Heart Disease in Study

    Science.gov (United States)

    ... medlineplus.gov/news/fullstory_164472.html High-Dose Vitamin D Failed to Curb Heart Disease in Study ... 5, 2017 (HealthDay News) -- Taking high doses of vitamin D once a month won't lower your ...

  19. 18 F-FDG PET-CT during chemo-radiotherapy in patients with non-small cell lung cancer: the early metabolic response correlates with the delivered radiation dose

    Directory of Open Access Journals (Sweden)

    Massaccesi Mariangela

    2012-07-01

    Full Text Available Abstract Background To evaluate the metabolic changes on 18 F-fluoro-2-deoxyglucose positron emission tomography integrated with computed tomography (18 F-FDG PET-CT performed before, during and after concurrent chemo-radiotherapy in patients with locally advanced non-small cell lung cancer (NSCLC; to correlate the metabolic response with the delivered radiation dose and with the clinical outcome. Methods Twenty-five NSCLC patients candidates for concurrent chemo-radiotherapy underwent 18 F-FDG PET-CT before treatment (pre-RT PET-CT, during the third week (during-RT PET-CT of chemo-radiotherapy, and 4 weeks from the end of chemo-radiotherapy (post-RT PET-CT. The parameters evaluated were: the maximum standardized uptake value (SUVmax of the primary tumor, the SUVmax of the lymph nodes, and the Metabolic Tumor Volume (MTV. Results SUVmax of the tumor and MTV significantly (p=0.0001, p=0.002, respectively decreased earlier during the third week of chemo-radiotherapy, with a further reduction 4 weeks from the end of treatment (p Conclusions In patients with locally advanced NSCLC, 18 F-FDG PET-CT performed during and after treatment allows early metabolic modifications to be detected, and for this SUVmax is the more sensitive parameter. Further studies are needed to investigate the correlation between the metabolic modifications during therapy and the clinical outcome in order to optimize the therapeutic strategy. Since the metabolic activity during chemo-radiotherapy correlates with the cumulative dose of fractionated radiotherapy delivered at the moment of the scan, special attention should be paid to methodological aspects, such as the radiation dose reached at the time of PET.

  20. Dose Response for Chromosome Aberrations in Human Lymphocytes and Fibroblasts After Exposure to Very Low Dose of High Let Radiation

    Science.gov (United States)

    Hada, M.; George, K.; Chappell, L.; Cucinotta, F. A.

    2011-01-01

    The relationship between biological effects and low doses of absorbed radiation is still uncertain, especially for high LET radiation exposure. Estimates of risks from low-dose and low-dose-rates are often extrapolated using data from Japanese atomic bomb survivor with either linear or linear quadratic models of fit. In this study, chromosome aberrations were measured in human peripheral blood lymphocytes and normal skin fibroblasts cells after exposure to very low dose (0.01 - 0.20 Gy) of 170 MeV/u Si-28 ions or 600 MeV/u Fe-56 ions, including doses where on average less than one direct ion traversal per cell nucleus occurs. Chromosomes were analyzed using the whole-chromosome fluorescence in situ hybridization (FISH) technique during the first cell division after irradiation, and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving >2 breaks in 2 or more chromosomes). The responses for doses above 0.1 Gy (more than one ion traverses a cell) showed linear dose responses. However, for doses less than 0.1 Gy, both Si-28 ions and Fe-56 ions showed a dose independent response above background chromosome aberrations frequencies. Possible explanations for our results are non-targeted effects due to aberrant cell signaling [1], or delta-ray dose fluctuations [2] where a fraction of cells receive significant delta-ray doses due to the contributions of multiple ion tracks that do not directly traverse cell nuclei where chromosome aberrations are scored.

  1. Small bowel toxicity after high dose spot scanning-based proton beam therapy for paraspinal/retroperitoneal neoplasms

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, R.A.; Albertini, F.; Koch, T.; Ares, C.; Lomax, A.; Goitein, G. [Paul Scherrer Institute PSI, Villigen (Switzerland). Center for Proton Therapy; Vitolo, V. [Fondazione CNAO, Pavia (Italy); Hug, E.B. [Paul Scherrer Institute PSI, Villigen (Switzerland). Center for Proton Therapy; ProCure Proton Therapy Centers, New York, NY (United States)

    2013-12-15

    Purpose: Mesenchymal tumours require high-dose radiation therapy (RT). Small bowel (SB) dose constraints have historically limited dose delivery to paraspinal and retroperitoneal targets. This retrospective study correlated SB dose-volume histograms with side-effects after proton radiation therapy (PT). Patients and methods: Between 1997 and 2008, 31 patients (mean age 52.1 years) underwent spot scanning-based PT for paraspinal/retroperitoneal chordomas (81 %), sarcomas (16 %) and meningiom (3 %). Mean total prescribed dose was 72.3 Gy (relative biologic effectiveness, RBE) delivered in 1.8-2 Gy (RBE) fractions. Mean follow-up was 3.8 years. Based on the pretreatment planning CT, SB dose distributions were reanalysed. Results: Planning target volume (PTV) was defined as gross tumour volume (GTV) plus 5-7 mm margins. Mean PTV was 560.22 cm{sup 3}. A mean of 93.2 % of the PTV was covered by at least 90 % of the prescribed dose. SB volumes (cm{sup 3}) receiving doses of 5, 20, 30, 40, 50, 60, 70, 75 and 80 Gy (RBE) were calculated to give V5, V20, V30, V40, V50, V60, V70, V75 and V80 respectively. In 7/31 patients, PT was accomplished without any significant SB irradiation (V5 = 0). In 24/31 patients, mean maximum dose (Dmax) to SB was 64.1 Gy (RBE). Despite target doses of > 70 Gy (RBE), SB received > 50 and > 60 Gy (RBE) in only 61 and 54 % of patients, respectively. Mean SB volumes (cm{sup 3}) covered by different dose levels (Gy, RBE) were: V20 (n = 24): 45.1, V50 (n = 19): 17.7, V60 (n = 17): 7.6 and V70 (n = 12): 2.4. No acute toxicity {>=} grade 2 or late SB sequelae were observed. Conclusion: Small noncircumferential volumes of SB tolerated doses in excess of 60 Gy (RBE) without any clinically-significant late adverse effects. This small retrospective study has limited statistical power but encourages further efforts with higher patient numbers to define and establish high-dose threshold models for SB toxicity in modern radiation oncology. (orig.)

  2. The ELIXIR-EXCELERATE Train-the-Trainer pilot programme: empower researchers to deliver high-quality training.

    Science.gov (United States)

    Morgan, Sarah L; Palagi, Patricia M; Fernandes, Pedro L; Koperlainen, Eija; Dimec, Jure; Marek, Diana; Larcombe, Lee; Rustici, Gabriella; Attwood, Teresa K; Via, Allegra

    2017-01-01

    One of the main goals of the ELIXIR-EXCELERATE project from the European Union's Horizon 2020 programme is to support a pan-European training programme to increase bioinformatics capacity and competency across ELIXIR Nodes. To this end, a Train-the-Trainer (TtT) programme has been developed by the TtT subtask of EXCELERATE's Training Platform, to try to expose bioinformatics instructors to aspects of pedagogy and evidence-based learning principles, to help them better design, develop and deliver high-quality training in future. As a first step towards such a programme, an ELIXIR-EXCELERATE TtT (EE-TtT) pilot was developed, drawing on existing 'instructor training' models, using input both from experienced instructors and from experts in bioinformatics, the cognitive sciences and educational psychology. This manuscript describes the process of defining the pilot programme, illustrates its goals, structure and contents, and discusses its outcomes. From Jan 2016 to Jan 2017, we carried out seven pilot EE-TtT courses (training more than sixty new instructors), collaboratively drafted the training materials, and started establishing a network of trainers and instructors within the ELIXIR community. The EE-TtT pilot represents an essential step towards the development of a sustainable and scalable ELIXIR TtT programme. Indeed, the lessons learned from the pilot, the experience gained, the materials developed, and the analysis of the feedback collected throughout the seven pilot courses have both positioned us to consolidate the programme in the coming years, and contributed to the development of an enthusiastic and expanding ELIXIR community of instructors and trainers.

  3. Analysis of renal impairment in MM-003, a phase III study of pomalidomide + low - dose dexamethasone versus high - dose dexamethasone in refractory or relapsed and refractory multiple myeloma

    OpenAIRE

    Weisel, Katja C.; Dimopoulos, Meletios A.; Moreau, Philippe; Lacy, Martha Q.; Song, Kevin W.; Delforge, Michel; Karlin, Lionel; Goldschmidt, Hartmut; Banos, Anne; Oriol, Albert; Alegre, Adrian; Chen, Christine; Cavo, Michele; Garderet, Laurent; Ivanova, Valentina

    2016-01-01

    Pomalidomide + low-dose dexamethasone is effective and well tolerated for refractory or relapsed and refractory multiple myeloma after bortezomib and lenalidomide failure. The phase III trial MM-003 compared pomalidomide + low-dose dexamethasone with high-dose dexamethasone. This subanalysis grouped patients by baseline creatinine clearance ≥ 30 − < 60 mL/min (n=93, pomalidomide + low-dose dexamethasone; n=56, high-dose dexamethasone) or ≥ 60 mL/min (n=205, pomalidomide + low-dose dexamethaso...

  4. Antagonism by idazoxan at low dose but not high dose, of the natriuretic action of moxonidine.

    Science.gov (United States)

    Allan, D. R.; Penner, S. B.; Smyth, D. D.

    1996-01-01

    1. Recent studies concerning the imidazoline receptor have utilized idazoxan as a specific imidazoline receptor antagonist. The aim of the present study was to describe the in vivo effects of various doses of idazoxan on renal function, in the presence and absence of moxonidine, an I1 imidazoline receptor agonist. 2. In anaesthetized, unilaterally nephrectomized (7 to 10 days) Sprague Dawley rats, an intrarenal infusion of moxonidine (3 nmol kg-1 min-1) increased urine flow rate, sodium excretion and osmolar clearance without altering free water clearance. Pretreatment with intravenous idazoxan at 0.1 and 0.3 mg kg-1 produced a dose-related decrease in the renal actions of moxonidine. However, a higher dose of idazoxan (1 mg kg-1) was not as effective as the 0.3 mg kg-1 dose in blocking the effects of moxonidine. 3. In a separate series of experiments, the direct renal actions of idazoxan alone were investigated. Idazoxan at 0.3 mg kg-1 failed to alter urine flow rate and sodium excretion. However, idazoxan at 1 mg kg-1 produced a significant increase in urine flow rate and sodium excretion in association with an increase in osmolar clearance. 4. These results do not prove but are consistent with low doses of idazoxan antagonizing the sites stimulated by moxonidine (renal imidazoline receptors). However, at higher doses, idazoxan may function as a partial agonist and/or interact with other receptors to increase urine flow rate, independent of imidazoline receptor blockade. These studies underscore the importance of the dose of idazoxan administered when this antagonist is used as a tool to investigate imidazoline receptors. PMID:8825339

  5. Comparison of commercial thermoluminescent readers regarding high-dose high-temperature measurements

    CERN Document Server

    Bilski, P; Obryk, B; Hodyr, K

    2014-01-01

    Three different thermoluminescent measuring systems have been compared with respect to the differences in temperature profiles, spectral sensitivities, as well as linearity of dose response characteristics. The comparison was performed using the Harshaw 3500, Riso DA-20 and RA94 TLD readers. The instruments were tested for the readouts of highly irradiated LiF:Mg,Cu,P (MCP) TL detectors, which require readout up to 550 C, in case of doses exceeding 1 kGy. It was found that the Harshaw 3500 can be used, without any additional light attenuation, for the measurements of MCP detectors exposed to doses up to about 5 Gy. For the other two readers the upper dose limit is about 5 times lower. It was also found that the Harshaw 3500 shows the best thermal stability considering the peak maximum position. For the ultra-high doses the differences in the spectral characteristics of the applied optical filters and photomultipliers, in conjunction with an evolution of the MCP TL emission spectrum with increasing dose, signi...

  6. Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements

    Science.gov (United States)

    Whitaker, May

    2016-01-01

    Purpose Inverse planning simulated annealing (IPSA) optimized brachytherapy treatment plans are characterized with large isolated dwell times at the first or last dwell position of each catheter. The potential of catheter shifts relative to the target and organs at risk in these plans may lead to a more significant change in delivered dose to the volumes of interest relative to plans with more uniform dwell times. Material and methods This study aims to determine if the Nucletron Oncentra dwell time deviation constraint (DTDC) parameter can be optimized to improve the robustness of high-dose-rate (HDR) prostate brachytherapy plans to catheter displacements. A set of 10 clinically acceptable prostate plans were re-optimized with a DTDC parameter of 0 and 0.4. For each plan, catheter displacements of 3, 7, and 14 mm were retrospectively applied and the change in dose volume histogram (DVH) indices and conformity indices analyzed. Results The robustness of clinically acceptable prostate plans to catheter displacements in the caudal direction was found to be dependent on the DTDC parameter. A DTDC value of 0 improves the robustness of planning target volume (PTV) coverage to catheter displacements, whereas a DTDC value of 0.4 improves the robustness of the plans to changes in hotspots. Conclusions The results indicate that if used in conjunction with a pre-treatment catheter displacement correction protocol and a tolerance of 3 mm, a DTDC value of 0.4 may produce clinically superior plans. However, the effect of the DTDC parameter in plan robustness was not observed to be as strong as initially suspected. PMID:27504129

  7. Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements.

    Science.gov (United States)

    Poder, Joel; Whitaker, May

    2016-06-01

    Inverse planning simulated annealing (IPSA) optimized brachytherapy treatment plans are characterized with large isolated dwell times at the first or last dwell position of each catheter. The potential of catheter shifts relative to the target and organs at risk in these plans may lead to a more significant change in delivered dose to the volumes of interest relative to plans with more uniform dwell times. This study aims to determine if the Nucletron Oncentra dwell time deviation constraint (DTDC) parameter can be optimized to improve the robustness of high-dose-rate (HDR) prostate brachytherapy plans to catheter displacements. A set of 10 clinically acceptable prostate plans were re-optimized with a DTDC parameter of 0 and 0.4. For each plan, catheter displacements of 3, 7, and 14 mm were retrospectively applied and the change in dose volume histogram (DVH) indices and conformity indices analyzed. The robustness of clinically acceptable prostate plans to catheter displacements in the caudal direction was found to be dependent on the DTDC parameter. A DTDC value of 0 improves the robustness of planning target volume (PTV) coverage to catheter displacements, whereas a DTDC value of 0.4 improves the robustness of the plans to changes in hotspots. The results indicate that if used in conjunction with a pre-treatment catheter displacement correction protocol and a tolerance of 3 mm, a DTDC value of 0.4 may produce clinically superior plans. However, the effect of the DTDC parameter in plan robustness was not observed to be as strong as initially suspected.

  8. ``In vivo'' Dose Measurements in High-Dose-Rate Brachytherapy Treatments for Cervical Cancer: A Project Proposal

    Science.gov (United States)

    Mejía, C. A. Reynoso; Burgos, A. E. Buenfil; Trejo, C. Ruiz; García, A. Mota; Durán, E. Trejo; Ponce, M. Rodríguez; de Buen, I. Gamboa

    2010-12-01

    The aim of this thesis project is to compare doses calculated from the treatment planning system using computed tomography images, with those measured "in vivo" by using thermoluminescent dosimeters placed at different regions of the rectum and bladder of a patient during high-dose-rate intracavitary brachytherapy treatment of uterine cervical carcinoma. The experimental dosimeters characterisation and calibration have concluded and the protocol to carry out the "in vivo" measurements has been established. In this work, the calibration curves of two types of thermoluminescent dosimeters (rods and chips) are presented, and the proposed protocol to measure the "in vivo" dose is fully described.

  9. Very high dose phenobarbital for refractory status epilepticus.

    Science.gov (United States)

    Tiamkao, Somsak; Mayurasakorn, Nattakarn; Suko, Panit; Jitpimolmard, Suthipun; Arunpongpaisal, Suwanna; Phuttharak, Warinthorn; Auevitchayapat, Narong; Vannaprasaht, Suda; Tiamkao, Siriporn; Phunikhom, Kutcharin; Chaiyakum, Aporanee; Saengsuwan, Jiamjit

    2007-12-01

    Refractory status epilepticus (RSE), defined as status epilepticus that fails to respond to first, second and third-line therapy. The RSE is associated with high morbidity and mortality. Treatment guidelines of RSE give a spectrum of options, such as, continuous intravenous (i.v.) midazolam (MDL), or continuous i.v. propofol (PRO) as alternatives to phenobarbital (PB) or continuous i.v. pentobarbital (PTB). To study the efficacy of very-high-dose phenobarbital (VHDPB) for treatment RSE. Retrospective study The authors collected and analyzed data from adult patients who were diagnosed with RSE. The authors present 10 patients with RSE who were treated with VHDPB. All of them were generalized convulsive status epilepticus (GCSE). Ages ranged from 16-86 years old (mean.: 43 years). PB dosage ranged 40-140 mg/kg/day (mean: 70 mg/kg/day). The duration of status epilepticus (SE) varied widely, ranged 1-44 days (mean: 7 days). PB level ranged 35.29-218.34 ug/mL (mean 88.1 ug/mL). RSE was controlled by VHDPB 70%, 30% were not controlled. VHDPB were considered as alternative treatment for RSE.

  10. High-dose pyridoxine as an 'anti-stress' strategy.

    Science.gov (United States)

    McCarty, M F

    2000-05-01

    Pyridoxine nutritional status has a significant and selective modulatory impact on central production of both serotonin and GABA - neurotransmitters which control depression, pain perception, and anxiety - owing to the fact that the decarboxylases which produce these neurotransmitters have a relatively low affinity for pyridoxal phosphate (PLP). Pyridoxine deficiency leads to increased sympathetic outflow and hypertension in rodents, possibly reflecting decreased central production of these neurotransmitters; conversely, supplemental pyridoxine lowers blood pressure in many animal models of hypertension, and there is preliminary evidence for antihypertensive activity in humans as well. Additionally, physiological levels of PLP interact with glucocorticoid receptors to down-regulate their activity. Thus, high-dose pyridoxine, by amplifying tissue levels of PLP, may be expected to have a favorable impact on certain dysphoric mental states, while diminishing sympathetic output and acting peripherally to blunt the physiological impact of corticosteroids. In light of growing evidence that chronic dysphoria, particularly when accompanied by hopelessness or cynicism, has a major negative impact on morbidity and mortality from a wide range of disorders, high intakes of pyridoxine may have the potential to improve prognosis in many individuals. With respect to cardiovascular health, reduction of homocysteine levels should contribute to this benefit. These predictions are consistent with recent epidemiology correlating plasma PLP levels with risk for vascular events and overall survival.

  11. Phase I Trial of Pelvic Nodal Dose Escalation With Hypofractionated IMRT for High-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Adkison, Jarrod B.; McHaffie, Derek R.; Bentzen, Soren M.; Patel, Rakesh R.; Khuntia, Deepak [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States); Petereit, Daniel G. [Department of Radiation Oncology, John T. Vucurevich Regional Cancer Care Institute, Rapid City Regional Hospital, Rapid City, SD (United States); Hong, Theodore S.; Tome, Wolfgang [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States); Ritter, Mark A., E-mail: ritter@humonc.wisc.edu [Department of Human Oncology, University of Wisconsin Carbone Cancer Center, School of Medicine and Public Health, Madison, WI (United States)

    2012-01-01

    Purpose: Toxicity concerns have limited pelvic nodal prescriptions to doses that may be suboptimal for controlling microscopic disease. In a prospective trial, we tested whether image-guided intensity-modulated radiation therapy (IMRT) can safely deliver escalated nodal doses while treating the prostate with hypofractionated radiotherapy in 5 Vulgar-Fraction-One-Half weeks. Methods and Materials: Pelvic nodal and prostatic image-guided IMRT was delivered to 53 National Comprehensive Cancer Network (NCCN) high-risk patients to a nodal dose of 56 Gy in 2-Gy fractions with concomitant treatment of the prostate to 70 Gy in 28 fractions of 2.5 Gy, and 50 of 53 patients received androgen deprivation for a median duration of 12 months. Results: The median follow-up time was 25.4 months (range, 4.2-57.2). No early Grade 3 Radiation Therapy Oncology Group or Common Terminology Criteria for Adverse Events v.3.0 genitourinary (GU) or gastrointestinal (GI) toxicities were seen. The cumulative actuarial incidence of Grade 2 early GU toxicity (primarily alpha blocker initiation) was 38%. The rate was 32% for Grade 2 early GI toxicity. None of the dose-volume descriptors correlated with GU toxicity, and only the volume of bowel receiving {>=}30 Gy correlated with early GI toxicity (p = 0.029). Maximum late Grades 1, 2, and 3 GU toxicities were seen in 30%, 25%, and 2% of patients, respectively. Maximum late Grades 1 and 2 GI toxicities were seen in 30% and 8% (rectal bleeding requiring cautery) of patients, respectively. The estimated 3-year biochemical control (nadir + 2) was 81.2 {+-} 6.6%. No patient manifested pelvic nodal failure, whereas 2 experienced paraaortic nodal failure outside the field. The six other clinical failures were distant only. Conclusions: Pelvic IMRT nodal dose escalation to 56 Gy was delivered concurrently with 70 Gy of hypofractionated prostate radiotherapy in a convenient, resource-efficient, and well-tolerated 28-fraction schedule. Pelvic nodal dose

  12. A comparison of high-dose and low-dose tranexamic acid antifibrinolytic protocols for primary coronary artery bypass surgery

    Directory of Open Access Journals (Sweden)

    Stephen M McHugh

    2016-01-01

    Full Text Available Background and Aims: Tranexamic acid (TA is used for prophylactic antifibrinolysis in coronary artery bypass surgeries to reduce bleeding. We evaluated the efficacy of two different doses of TA for prophylactic antifibrinolysis in patients undergoing primary coronary artery bypass grafting (CABG surgery in this retrospective cohort study at a tertiary care referral centre. Methods: One-hundred eighty-four patients who underwent primary CABG with cardiopulmonary bypass (CPB via sternotomy between January 2009 and June 2011 were evaluated. Pre-operative patient characteristics, intraoperative data, post-operative bleeding, transfusions, organ dysfunction and 30-day mortality were compared between high-dose TA (30 mg/kg loading dose followed by infusion of 15 mg/kg/h until the end of surgery along with 2 mg/kg priming dose in the bypass circuit and low-dose TA (15 mg/kg loading dose followed by infusion of 6 mg/kg/h until the end of surgery along with 1 mg/kg priming dose in the bypass circuit groups. Univariate comparative analysis of all categorical and continuous variables was performed between the two groups by appropriate statistical tests. Linear and logistic regression analyses were performed to control for the effect of confounding on the outcome variables. Results: Chest tube output, perioperative transfusion of blood products and incidence of re-exploration for bleeding did not differ significantly (P> 0.05 between groups. Post-operative complications and 30-day mortality were comparable between the groups. The presence of cardiogenic shock and increased pre-operative creatinine were found to be associated with increased chest tube output on the post-operative day 2 by multivariable linear regression model. Conclusions: Low-dose TA protocol is as effective as high-dose protocol for antifibrinolysis in patients undergoing primary CABG with CPB.

  13. Efficacy of a single high dose versus multiple low doses of LLLT on wounded skin fibroblasts

    Science.gov (United States)

    Hawkins, Denise H.; Abrahamse, Heidi

    2007-07-01

    Background/purpose: In vivo studies have demonstrated that phototherapy accelerates wound healing in the clinical environment; however the exact mechanism is still not completely understood. The main focus of this study was to use in vitro laboratory results to establish an effective treatment regimen that may be practical and applicable to the clinical environment. This in vitro study aimed to compare the cellular responses of wounded fibroblasts following a single exposure of 5 J/cm2 or multiple exposures of low doses (2.5 J/cm2 or 5 J/cm2) on one day of the week to a single application of a higher dose (16 J/cm2) on day 1 and day 4. Methodology: Cellular responses to Helium-Neon (632.8 nm) laser irradiation were evaluated by measuring changes in cell morphology, cell viability, cell proliferation, membrane integrity and DNA damage. Results: Wounded cells exposed to 5 J/cm2 on day 1 and day 4 showed an increase in cell viability, increase in the release of bFGF, increase in cell density, decrease in ALP enzyme activity and decrease in caspase 3/7 activity indicating a stimulatory effect. Wounded cells exposed to three doses of 5 J/cm2 on day 1 showed a decrease in cell viability and cell proliferation and an increase in LDH cytotoxicity and DNA damage indicating an inhibitory effect. Conclusion: Results indicate that cellular responses are influenced by the combination of dose administered, number of exposures and time between exposures. Single doses administered with sufficient time between exposures is more beneficial to restoring cell function than multiple doses within a short period. Although this work confirms previous reports on the cumulative effect of laser irradiation it provides essential information for the initiation of in vivo clinical studies.

  14. Dose Response for Chromosome Aberrations in Human Lymphocytes and Fibroblasts after Exposure to Very Low Doses of High LET Radiation

    Science.gov (United States)

    Hada, M.; George, Kerry; Cucinotta, Francis A.

    2011-01-01

    The relationship between biological effects and low doses of absorbed radiation is still uncertain, especially for high LET radiation exposure. Estimates of risks from low-dose and low-dose-rates are often extrapolated using data from Japanese atomic bomb survivors with either linear or linear quadratic models of fit. In this study, chromosome aberrations were measured in human peripheral blood lymphocytes and normal skin fibroblasts cells after exposure to very low dose (1-20 cGy) of 170 MeV/u Si-28- ions or 600 MeV/u Fe-56-ions. Chromosomes were analyzed using the whole chromosome fluorescence in situ hybridization (FISH) technique during the first cell division after irradiation, and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving greater than 2 breaks in 2 or more chromosomes). The curves for doses above 10 cGy were fitted with linear or linear-quadratic functions. For Si-28- ions no dose response was observed in the 2-10 cGy dose range, suggesting a non-target effect in this range.

  15. Cutaneous dosimetry at low and high dose; Dosimetrie cutanee a faible et forte dose

    Energy Technology Data Exchange (ETDEWEB)

    Martin, M. [CEA, iRCM, Laboratoire de Genomique et Radiobiologie de la Keratinopoiese, 2 rue G Cremieux, Evry, 91057, Evry cedex (France)

    2009-07-01

    As radiodermatitis is a complication related to the exposure to ionizing radiation after an accidental exposition or a medical examination (radiotherapy or interventional radiology), the author briefly reports an investigation of the response of the human keratinocyte to irradiation for different dose levels, and the search for exposure markers

  16. A narrow-band wavelength-tunable laser system delivering high-energy 300 ps pulses in the near-infrared

    NARCIS (Netherlands)

    Brandi, F.; Velchev, I.; Neshev, D.; Hogervorst, W.; Ubachs, W.M.G.

    2003-01-01

    We report on the operation of a novel laser system delivering high-energy pulses in the near-infrared region. The pulses are nearly Fourier-transform limited (time-bandwidth product of 0.48), providing narrow-band radiation (similar to1.5 GHz), with an energy of 225 mJ and 10 Hz repetition rate. The

  17. The application of high dose food irradiation in South Africa

    Science.gov (United States)

    de Bruyn, Ingrid Nine

    2000-03-01

    During the 1950s to the end of the 1970s the United States Army developed the basic methodology to produce shelf-stable irradiated meat, seafood and poultry products. These products are normally packed without gravy, sauce or brine, as liquid is not required to sterilize the product as in the canning process. This leads to the distinctive "dried cooked" taste normally associated with roasts opposed to the casserole taste usually associated with tinned meats. The Biogam group at the Atomic Energy Corporation of South Africa is currently producing shelf-stable irradiated meats on a commercial basis. The meats are cooked, chilled, portioned, vacuum packed and irradiated to the required minimum dose of 45 kGy at a temperature of between -20 and -40°C to ensure absolute sterility even under tropical conditions. The product is packaged in a high quality four layer laminate pouch and will therefore not rust or burst even under adverse weather conditions and can be guaranteed for more than two years as long as the integrity of the packaging is maintained. Safari operators in remote parts of Africa, mountaineers, yachtsmen, canoeists and geological survey teams currently use shelf-stable irradiated meat products produced in South Africa.

  18. Displacement damage effects in silicon MEMS at high proton doses

    Science.gov (United States)

    Gomes, João; Shea, Herbert R.

    2011-02-01

    We report on a study of the sensitivity of silicon MEMS to proton radiation and mitigation strategies. MEMS can degrade due to ionizing radiation (electron-hole pair creation) and non-ionizing radiation (displacement damage), such as electrons, trapped and solar protons, or cosmic rays, typically found in a space environment. Over the past few years there has been several reports on the effects of ionizing radiation in silicon MEMS, with failure generally linked to trapped charge in dielectrics. However there is near complete lack of studies on displacement damage effects in silicon- MEMS: how does silicon change mechanically due to proton irradiation? We report on an investigation on the susceptibility of 50 μm thick SOI-based MEMS resonators to displacement damages due to proton beams, with energies from 1 to 60 MeV, and annealing of this damage. We measure ppm changes on the Young's modulus and Poisson ratio by means of accurately monitoring the resonant frequency of devices in vacuum using a Laser Doppler Vibrometer. We observed for the first time an increase (up to 0.05%) of the Young's modulus of single-crystal silicon electromagnetically-actuated micromirrors after exposure to low energy protons (1-4 MeV) at high absorbed doses ~ 100 Mrad (Si). This investigation will contribute to a better understanding of the susceptibility of silicon-based MEMS to displacement damages frequently encountered in a space radiation environment, and allow appropriated design margin and shielding to be implemented.

  19. Malignancies in patients treated with high doses of radium-224

    Energy Technology Data Exchange (ETDEWEB)

    Nekolla, E.A. [Federal Office for Radiation Protection (BfS), Neuherberg (Germany); Walsh, L. [Radiobiological Inst., Univ. of Munich (Germany); Schottenhammer, G.; Spiess, H. [Children' s Hospital, Univ. of Munich (Germany)

    2005-07-01

    Several thousand German patients suffering from ankylosing spondylitis, tuberculosis and some other diseases, received multiple injections of the short-lived {alpha}-emitter {sup 224}Ra. The ''Spiess study'' was initiated in the early 1950s to follow the health of 899 persons (278 female, 621 male) who were treated mainly between 1945 and 1955. Most of the high dose patients and nearly all of those treated as children or juveniles (n=217) were included in the study. In June 2003, 152 persons were still alive. The most striking observed health effect, following {sup 224}Ra injections, was a temporal wave of 56 malignant bone tumours with a maximum at about 8 years after exposure which has already been described in several publications. In 2000, a new analysis was performed because an improved dosimetry resulted in modified bone surface doses. The estimated risk coefficient, averaged over all ages at exposure, was found to be in agreement with earlier analyses. However, a statistically significant increase of bone tumour risk with decreasing age at exposure was found. The earlier results, which indicated a reversed protraction factor, were confirmed. A significant excess of non-skeletal solid malignancies has also appeared during the most recent observation decade. In 2004, significant increases of cancer rates were observed for several sites: for breast cancer (31 cases observed vs. 9.1 cases expected), soft tissue malignancies (11 vs. 1.0), thyroid carcinomas (7 vs. 0.9), liver (8 vs. 2.3), kidney (13 vs. 4.6), pancreas (8 vs. 3.9), and bladder cancer (14 vs. 7.7). The 8-fold excess relative risk of mammary cancers in those women exposed as children or juveniles is particularly striking; moreover, 2 cases of breast cancer occurred in men. In 1993, a control group of tuberculosis patients not treated with {sup 224}Ra was established to rule out potential confounding factors - such as chest fluoroscopy - which might bias the breast cancer excess

  20. Modulation of the proteolytic cascade systems by high dose corticosteroids.

    Science.gov (United States)

    Aasen, A O; Ruud, T E; Pillgram-Larsen, J; Röise, O; Stadaas, J

    1985-01-01

    The effects of high-dose corticosteroids (HDC) on activities within the proteolytic cascade systems were studied in vitro and in vivo using chromogenic peptide substrate assays. In in vitro experiments 20 mg methylprednisolone sodium succinate (Solu-Medrol) per ml plasma significantly inhibited activation of plasma prekallikrein, prothrombin and plasminogen and reduced functional plasma kallikrein inhibition, antithrombin and antiplasmin activities. The effects of HDC on activities within these proteolytic cascade systems were further evaluated in experimental acute pancreatitis in pigs. Acute pancreatitis was induced by injection of Na-taurocholate into the pancreatic duct. Seven test animals received methylprednisolone sodium succinate 30 mg per kg intravenously for 30 minutes before the induction of pancreatitis as pretreatment. Eight animals remained untreated. Trypsin (TRY), plasma prekallikrein (PKK), plasma kallikrein (KK) and functional plasma kallikrein inhibition capacity (KKI) were studied in the peritoneal exudate. Cardiac output (CO) and mean arterial pressure (MAP) were monitored regularly before and during a 6 hour observation period. During untreated pancreatitis a reduction of PKK levels of about 40% were found, paralleled by an increased KK activity and a reduction of KKI capacity. Several of the animals experienced high TRY activities. The mortality rate was 63% (5 out of 8 animals). In the pretreated groups, all animals survived the observation period. CO and MAP were significantly less reduced than the untreated group at 6 hours. HDC was also found to reduce significantly plasma kallikrein activities in the peritoneal exudate compared with untreated animals. No changes in TRY activities were found in pretreated animals. Furthermore, plasma prekallikrein and functional plasma kallikrein inhibition values in the exudate were elevated significantly in HDC treated animals compared with untreated animals.

  1. Molecular mechanisms linking high dose medroxyprogesterone with HIV-1 risk.

    Directory of Open Access Journals (Sweden)

    Susan C Irvin

    Full Text Available Epidemiological studies suggest that medroxyprogesterone acetate (MPA may increase the risk of HIV-1. The current studies were designed to identify potential underlying biological mechanisms.Human vaginal epithelial (VK2/E6E7, peripheral blood mononuclear (PBMC, and polarized endometrial (HEC-1-A cells were treated with a range of concentrations of MPA (0.015-150 μg/ml and the impact on gene expression, protein secretion, and HIV infection was evaluated.Treatment of VK2/E6E7 cells with high doses (>15 μg/ml] of MPA significantly upregulated proinflammatory cytokines, which resulted in a significant increase in HIV p24 levels secreted by latently infected U1 cells following exposure to culture supernatants harvested from MPA compared to mock-treated cells. MPA also increased syndecan expression by VK2/E6E7 cells and cells treated with 15 μg/ml of MPA bound and transferred more HIV-1 to T cells compared to mock-treated cells. Moreover, MPA treatment of epithelial cells and PBMC significantly decreased cell proliferation resulting in disruption of the epithelial barrier and decreased cytokine responses to phytohaemagglutinin, respectively.We identified several molecular mechanisms that could contribute to an association between DMPA and HIV including proinflammatory cytokine and chemokine responses that could activate the HIV promoter and recruit immune targets, increased expression of syndecans to facilitate the transfer of virus from epithelial to immune cells and decreased cell proliferation. The latter could impede the ability to maintain an effective epithelial barrier and adversely impact immune cell function. However, these responses were observed primarily following exposure to high (15-150 μg/ml MPA concentrations. Clinical correlation is needed to determine whether the prolonged MPA exposure associated with contraception activates these mechanisms in vivo.

  2. Molecular mechanisms linking high dose medroxyprogesterone with HIV-1 risk.

    Science.gov (United States)

    Irvin, Susan C; Herold, Betsy C

    2015-01-01

    Epidemiological studies suggest that medroxyprogesterone acetate (MPA) may increase the risk of HIV-1. The current studies were designed to identify potential underlying biological mechanisms. Human vaginal epithelial (VK2/E6E7), peripheral blood mononuclear (PBMC), and polarized endometrial (HEC-1-A) cells were treated with a range of concentrations of MPA (0.015-150 μg/ml) and the impact on gene expression, protein secretion, and HIV infection was evaluated. Treatment of VK2/E6E7 cells with high doses (>15 μg/ml] of MPA significantly upregulated proinflammatory cytokines, which resulted in a significant increase in HIV p24 levels secreted by latently infected U1 cells following exposure to culture supernatants harvested from MPA compared to mock-treated cells. MPA also increased syndecan expression by VK2/E6E7 cells and cells treated with 15 μg/ml of MPA bound and transferred more HIV-1 to T cells compared to mock-treated cells. Moreover, MPA treatment of epithelial cells and PBMC significantly decreased cell proliferation resulting in disruption of the epithelial barrier and decreased cytokine responses to phytohaemagglutinin, respectively. We identified several molecular mechanisms that could contribute to an association between DMPA and HIV including proinflammatory cytokine and chemokine responses that could activate the HIV promoter and recruit immune targets, increased expression of syndecans to facilitate the transfer of virus from epithelial to immune cells and decreased cell proliferation. The latter could impede the ability to maintain an effective epithelial barrier and adversely impact immune cell function. However, these responses were observed primarily following exposure to high (15-150 μg/ml) MPA concentrations. Clinical correlation is needed to determine whether the prolonged MPA exposure associated with contraception activates these mechanisms in vivo.

  3. Antagonism by idazoxan at low dose but not high dose, of the natriuretic action of moxonidine.

    OpenAIRE

    D. R. Allan; Penner, S. B.; Smyth, D. D.

    1996-01-01

    1. Recent studies concerning the imidazoline receptor have utilized idazoxan as a specific imidazoline receptor antagonist. The aim of the present study was to describe the in vivo effects of various doses of idazoxan on renal function, in the presence and absence of moxonidine, an I1 imidazoline receptor agonist. 2. In anaesthetized, unilaterally nephrectomized (7 to 10 days) Sprague Dawley rats, an intrarenal infusion of moxonidine (3 nmol kg-1 min-1) increased urine flow rate, sodium excre...

  4. Treating glioblastoma multiforme with selective high-dose liposomal doxorubicin chemotherapy induced by repeated focused ultrasound

    Directory of Open Access Journals (Sweden)

    Yang FY

    2012-02-01

    Full Text Available Feng-Yi Yang1, Ming-Che Teng1, Maggie Lu2, Hsiang-Fa Liang2, Yan-Ru Lee1, Chueh-Chuan Yen3, Muh-Lii Liang4,5, Tai-Tong Wong51Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, 2Drug Delivery Laboratory, Biomedical Technology and Device Research Laboratories, Industrial Technology Research Institute, Hsinchu, 3Division of Hematology and Oncology, Department of Medicine, Taipei Veterans General Hospital and National Yang-Ming University School of Medicine, Taipei, 4Institute of Clinical Medicine, National Yang-Ming University School of Medicine, Taipei, 5Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital, Taipei, TaiwanBackground: High-dose tissue-specific delivery of therapeutic agents would be a valuable clinical strategy. We have previously shown that repeated transcranial focused ultrasound is able to increase the delivery of Evans blue significantly into brain tissue. The present study shows that repeated pulsed high-intensity focused ultrasound (HIFU can be used to deliver high-dose atherosclerotic plaque-specific peptide-1 (AP-1-conjugated liposomes selectively to brain tumors.Methods: Firefly luciferase (Fluc-labeled human GBM8401 glioma cells were implanted into NOD-scid mice. AP-1-conjugated liposomal doxorubicin or liposomal doxorubicin alone was administered followed by pulsed HIFU and the doxorubicin concentration in the treated brains quantified by fluorometer. Growth of the labeled glioma cells was monitored through noninvasive bioluminescence imaging and finally the brain tissue was histologically examined after sacrifice.Results: Compared with the control group, the animals treated with 5 mg/kg injections of AP-1 liposomal doxorubicin or untargeted liposomal doxorubicin followed by repeated pulsed HIFU not only showed significantly enhanced accumulation of drug at the sonicated tumor site but also a significantly elevated tumor-to-normal brain drug

  5. Dose painting to treat single-lobe prostate cancer with hypofractionated high-dose radiation using targeted external beam radiation: Is it feasible?

    Energy Technology Data Exchange (ETDEWEB)

    Amini, Arya; Westerly, David C.; Waxweiler, Timothy V.; Ryan, Nicole; Raben, David, E-mail: david.raben@ucdenver.edu

    2015-10-01

    Targeted focal therapy strategies for treating single-lobe prostate cancer are under investigation. In this planning study, we investigate the feasibility of treating a portion of the prostate to full-dose external beam radiation with reduced dose to the opposite lobe, compared with full-dose radiation delivered to the entire gland using hypofractionated radiation. For 10 consecutive patients with low- to intermediate-risk prostate cancer, 2 hypofractionated, single-arc volumetric-modulated arc therapy (VMAT) plans were designed. The first plan (standard hypofractionation regimen [STD]) included the entire prostate gland, treated to 70 Gy delivered in 28 fractions. The second dose painting plan (DP) encompassed the involved lobe treated to 70 Gy delivered in 28 fractions, whereas the opposing, uninvolved lobe received 50.4 Gy in 28 fractions. Mean dose to the opposing neurovascular bundle (NVB) was considerably lower for DP vs STD, with a mean dose of 53.9 vs 72.3 Gy (p < 0.001). Mean penile bulb dose was 18.6 Gy for DP vs 19.2 Gy for STD (p = 0.880). Mean rectal dose was 21.0 Gy for DP vs 22.8 Gy for STD (p = 0.356). Rectum V{sub 70} (the volume receiving ≥70 Gy) was 2.01% for DP vs 2.74% for STD (p = 0.328). Bladder V{sub 70} was 1.69% for DP vs 2.78% for STD (p = 0.232). Planning target volume (PTV) maximum dose points were 76.5 and 76.3 Gy for DP and STD, respectively (p = 0.760). This study demonstrates the feasibility of using VMAT for partial-lobe prostate radiation in patients with prostate cancer involving 1 lobe. Partial-lobe prostate plans appeared to spare adjacent critical structures including the opposite NVB.

  6. Chemotherapy of onchocerciasis with high doses of diethylcarbamazine or a single dose of ivermectin: microfilaria levels and side effects.

    Science.gov (United States)

    Albiez, E J; Newland, H S; White, A T; Kaiser, A; Greene, B M; Taylor, H R; Büttner, D W

    1988-03-01

    Fifty adult male subjects with moderate to heavy onchocerciasis from the Liberian rain forest were selected for a double-blind placebo-controlled chemotherapy study. The effects of high doses of diethylcarbamazine (DEC) - 30 mg/kg/d - over one week preceded by a one week initial treatment with normal oral doses of DEC or DEC lotion were compared with a single dose of ivermectin (150 micrograms/kg) and placebo. During the initial treatment DEC tablets or lotion caused distinctly more frequent and severe reactions than did invermectin. The reactions to ivermectin did not differ from those of the placebo patients. High doses of DEC caused, in about half of the patients, headache, dizziness, nausea or vomiting. DEC markedly increased the number of corneal microfilariae and of corneal opacities compared to ivermectin. All changes resolved with a return to pretreatment findings two months after treatment. The three treatment groups showed no differences at the ten months follow-up. In all treated patients skin microfilaria counts fell almost to zero by the end of the two week therapy. In the ivermectin group microfilaria counts remained significantly lower than in the DEC patients at the two and ten months examinations. In summary, ivermectin was much better tolerated than DEC and had a longer lasting effect on the microfilariae in the skin. Since high doses of DEC were less effective and caused more frequent and severe side effects, this approach cannot be recommended for treatment of onchocerciasis.

  7. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    CERN Document Server

    Sakamoto, Y; Sato, O; Tanaka, S I; Tsuda, S; Yamaguchi, Y; Yoshizawa, N

    2003-01-01

    In the International Commission on Radiological Protection (ICRP) 1990 Recommendations, radiation weighting factors were introduced in the place of quality factors, the tissue weighting factors were revised, and effective doses and equivalent doses of each tissues and organs were defined as the protection quantities. Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of theses data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality fact...

  8. Biological impact of high-dose and dose-rate radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Maliev, V.; Popov, D. [Russian Academy of Science, Vladicaucas (Russian Federation); Jones, J.; Gonda, S. [NASA -Johnson Space Center, Houston (United States); Prasad, K.; Viliam, C.; Haase, G. [Antioxida nt Research Institute, Premier Micronutrient Corporation, Novato (United States); Kirchin, V. [Moscow State Veterinary and Biotechnology Acade my, Moscow (Russian Federation); Rachael, C. [University Space Research Association, Colorado (United States)

    2006-07-01

    Experimental anti-radiation vaccine is a power tool of immune - prophylaxis of the acute radiation disease. Existing principles of treatment of the acute radiation dis ease are based on a correction of developing patho-physiological and biochemical processes within the first days after irradiation. Protection from radiation is built on the general principles of immunology and has two main forms - active and passive immunization. Active immunization by the essential radiation toxins of specific radiation determinant (S.D.R.) group allows significantly reduce the lethality and increase duration of life among animals that are irradiated by lethal and sub-lethal doses of gamma radiation.The radiation toxins of S.D.R. group have antigenic properties that are specific for different forms of acute radiation disease. Development of the specific and active immune reaction after intramuscular injection of radiation toxins allows optimize a manifestation of a clinical picture and stabilize laboratory parameters of the acute radiation syndromes. Passive immunization by the anti-radiation serum or preparations of immune-globulins gives a manifestation of the radioprotection effects immediately after this kind of preparation are injected into organisms of mammals. Providing passive immunization by preparations of anti-radiations immune-globulins is possible in different periods of time after radiation. Providing active immunization by preparations of S.D.R. group is possible only to achieve a prophylaxis goal and form the protection effects that start to work in 18 - 35 days after an injection of biological active S.D.R. substance has been administrated. However active and passive immunizations by essential anti-radiation toxins and preparations of gamma-globulins extracted from a hyper-immune serum of a horse have significantly different medical prescriptions for application and depend on many factors like a type of radiation, a power of radiation, absorption doses, a time of

  9. Cytogenetic dose-response in vitro for biological dosimetry after exposure to high doses of gamma-rays.

    Science.gov (United States)

    Vinnikov, Volodymyr A; Maznyk, Nataliya A

    2013-04-01

    The dose response for dicentrics plus centric rings and total unstable chromosome-type aberrations was studied in the first mitoses of cultured human peripheral blood lymphocytes irradiated in vitro to doses of ∼2, 4, 6, 8, 10, 16 and 20 Gy of acute (60)Со gamma-rays. A dose-dependent increase of aberration yield was accompanied by a tendency to the underdispersion of dicentrics and centric rings among cells distributions compared with Poisson statistics at doses ≥6 Gy. The formal fitting of the data to a linear-quadratic model resulted in an equation with the linear and quadratic coefficients ranged 0.098-0.129×cell(-1)×Gy(-1) and 0.039-0.034×cell(-1)×Gy(-2), respectively, depending on the fitting method. The actual radiation-induced aberration yield was markedly lower than expected from a calibration curve, generated earlier within a lower dose range. Interlaboratory variations in reported dicentric yields induced by medium-to-high radiation doses in vitro are discussed.

  10. Milk residues and performance of lactating dairy cows administered high doses of monensin

    OpenAIRE

    Bagg, Randal; Vessie, Gordon H.; Dick, C. Paul; Duffield, Todd; Wilson, Jeff B.; Aramini, Jeff J

    2005-01-01

    Milk residues and performance were evaluated in lactating cows that were fed up to 10 times the recommended dose of monensin. Following an acclimatization period of 14 d, during which cows were fed a standard lactating cow total mixed ration containing 24 ppm monensin, 18 lactating Holstein dairy cows were grouped according to the level of feed intake and then randomly assigned within each group to 1 of 3 challenge rations delivering 72, 144, and 240 ppm monensin. Outcome measurements include...

  11. Pharmacokinetics of Imipenem/Cilastatin Burn Intensive Care Unit Patients Undergoing High-Dose Continuous Venovenous Hemofiltration.

    Science.gov (United States)

    Boucher, Bradley A; Hudson, Joanna Q; Hill, David M; Swanson, Joseph M; Wood, G Christopher; Laizure, S Casey; Arnold-Ross, Angela; Hu, Zhe-Yi; Hickerson, William L

    2016-12-01

    High-dose continuous venovenous hemofiltration (CVVH) is a continuous renal replacement therapy (CRRT) used frequently in patients with burns. However, antibiotic dosing is based on inference from studies assessing substantially different methods of CRRT. To address this knowledge gap for imipenem/cilastatin (I/C), we evaluated the systemic and extracorporeal clearances (CLs) of I/C in patients with burns undergoing high-dose CVVH. Prospective clinical pharmacokinetic study. Ten adult patients with burns receiving I/C for a documented infection and requiring high-dose CVVH were studied. Blood and effluent samples for analysis of I/C concentrations were collected for up to 6 hours after the I/C infusion for calculation of I/C total CL (CLTotal ), CL by CVVH (CLHF ), half-life during CVVH, volume of distribution at steady state (Vdss ), and the percentage of drug eliminated by CVVH. In this patient sample, the mean age was 50 ± 17 years, total body surface area burns was 23 ± 27%, and 80% were male. Nine patients were treated with high-dose CVVH for acute kidney injury and one patient for sepsis. The mean delivered CVVH dose was 52 ± 14 ml/kg/hour (range 32-74 ml/kg/hr). The imipenem CLHF was 3.27 ± 0.48 L/hour, which accounted for 23 ± 4% of the CLTotal (14.74 ± 4.75 L/hr). Cilastatin CLHF was 1.98 ± 0.56 L/hour, which accounted for 45 ± 19% of the CLTotal (5.16 + 2.44 L/hr). The imipenem and cilastatin half-lives were 1.77 ± 0.38 hours and 4.21 ± 2.31 hours, respectively. Imipenem and cilastatin Vdss were 35.1 ± 10.3 and 32.8 ± 13.8 L, respectively. Efficient removal of I/C by high-dose CVVH, a high overall clearance, and a high volume of distribution in burn intensive care unit patients undergoing this CRRT method warrant aggressive dosing to treat serious infections effectively depending on the infection site and/or pathogen. © 2016 Pharmacotherapy Publications, Inc.

  12. Investigations of DNA damage induction and repair resulting from cellular exposure to high dose-rate pulsed proton beams

    Energy Technology Data Exchange (ETDEWEB)

    Renis, M.; Malfa, G.; Tomasello, B. [Drug Sciences Department, University of Catania, Catania (Italy); Borghesi, M.; Schettino, G. [Queen' s University Belfast, Northern Ireland (United Kingdom); Favetta, M.; Romano, F.; Cirrone, G. A. P. [National Institute for Nuclear Physics (INFN-LNS), Catania (Italy); Manti, L. [Physics Science Department, University of Naples Federico II, Naples, and National Institute for Nuclear Physics (INFN), Naples (Italy)

    2013-07-26

    Studies regarding the radiobiological effects of low dose radiation, microbeam irradiation services have been developed in the world and today laser acceleration of protons and heavy ions may be used in radiation therapy. The application of different facilities is essential for studying bystander effects and relating signalling phenomena in different cells or tissues. In particular the use of ion beams results advantageous in cancer radiotherapy compared to more commonly used X-rays, since the ability of ions in delivering lethal amount of doses into the target tumour avoiding or limiting damage to the contiguous healthy tissues. At the INFN-LNS in Catania, a multidisciplinary radiobiology group is strategically structured aimed to develop radiobiological research, finalised to therapeutic applications, compatible with the use of high dose laser-driven ion beams. The characteristic non-continuous dose rates with several orders of magnitude of laser-driven ion beams makes this facility very interesting in the cellular systems' response to ultra-high dose rates with non-conventional pulse time intervals cellular studies. Our group have projected to examine the effect of high dose laser-driven ion beams on two cellular types: foetal fibroblasts (normal control cells) and DU145 (prostate cancer cells), studying the modulation of some different bio-molecular parameters, in particular cell proliferation and viability, DNA damage, redox cellular status, morphological alterations of both the cytoskeleton components and some cell organelles and the possible presence of apoptotic or necrotic cell death. Our group performed preliminary experiments with high energy (60 MeV), dose rate of 10 Gy/min, doses of 1, 2, 3 Gy and LET 1 keV/μm on human foetal fibroblasts (control cells). We observed that cell viability was not influenced by the characteristics of the beam, the irradiation conditions or the analysis time. Conversely, DNA damage was present at time 0, immediately

  13. Effectiveness of High Dose Pralidoxime for Treatment of Organophosphate Poisoning

    Directory of Open Access Journals (Sweden)

    Pham Due

    2014-09-01

    Full Text Available Background: For effective treatment of organophosphate (OP poisoning, development of a standardized protocol with flexible dose regimen for atropine and pralidoxime is an essential step. In this study, we aimed to assess the protocol devised in our setting; Bach Mai Hospital Poison Treatment Center, for treatment of OP poisoning that included a higher dose regimen of pralidoxime (2PAM. Methods: A protocol for treatment of OP poisoning was developed during 1995 to 1996, which included an atropinization scoring scale and a modification of 2PAM dose regimen. In this study, OP poisoned patients who were treated during 1997 to 2002 with the new protocol (study group or cases were compared with historical control group which included OP poisoned patients treated between 1993 and 1994 prior to establishment of the new protocol. Results: One-hundred and eight cases and 54 controls were included. The cases and controls were not significantly different according to age, gender and plasma cholinesterase activity on admission from each other. There was no significant difference of mean duration of 2PAM therapy between the two groups. The controls received mean total 2PAM dose of 7.2±4.1 g, while the patients in the study group received 20.0±12.7 g which was 2.77 times higher than the dose for control group (P

  14. High-Dose-Rate Prostate Brachytherapy Consistently Results in High Quality Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    White, Evan C.; Kamrava, Mitchell R.; Demarco, John; Park, Sang-June; Wang, Pin-Chieh; Kayode, Oluwatosin; Steinberg, Michael L. [California Endocurietherapy at UCLA, Department of Radiation Oncology, David Geffen School of Medicine of University of California at Los Angeles, Los Angeles, California (United States); Demanes, D. Jeffrey, E-mail: jdemanes@mednet.ucla.edu [California Endocurietherapy at UCLA, Department of Radiation Oncology, David Geffen School of Medicine of University of California at Los Angeles, Los Angeles, California (United States)

    2013-02-01

    Purpose: We performed a dosimetry analysis to determine how well the goals for clinical target volume coverage, dose homogeneity, and normal tissue dose constraints were achieved with high-dose-rate (HDR) prostate brachytherapy. Methods and Materials: Cumulative dose-volume histograms for 208 consecutively treated HDR prostate brachytherapy implants were analyzed. Planning was based on ultrasound-guided catheter insertion and postoperative CT imaging; the contoured clinical target volume (CTV) was the prostate, a small margin, and the proximal seminal vesicles. Dosimetric parameters analyzed for the CTV were D90, V90, V100, V150, and V200. Dose to the urethra, bladder, bladder balloon, and rectum were evaluated by the dose to 0.1 cm{sup 3}, 1 cm{sup 3}, and 2 cm{sup 3} of each organ, expressed as a percentage of the prescribed dose. Analysis was stratified according to prostate size. Results: The mean prostate ultrasound volume was 38.7 {+-} 13.4 cm{sup 3} (range: 11.7-108.6 cm{sup 3}). The mean CTV was 75.1 {+-} 20.6 cm{sup 3} (range: 33.4-156.5 cm{sup 3}). The mean D90 was 109.2% {+-} 2.6% (range: 102.3%-118.4%). Ninety-three percent of observed D90 values were between 105 and 115%. The mean V90, V100, V150, and V200 were 99.9% {+-} 0.05%, 99.5% {+-} 0.8%, 25.4% {+-} 4.2%, and 7.8% {+-} 1.4%. The mean dose to 0.1 cm{sup 3}, 1 cm{sup 3}, and 2 cm{sup 3} for organs at risk were: Urethra: 107.3% {+-} 3.0%, 101.1% {+-} 14.6%, and 47.9% {+-} 34.8%; bladder wall: 79.5% {+-} 5.1%, 69.8% {+-} 4.9%, and 64.3% {+-} 5.0%; bladder balloon: 70.3% {+-} 6.8%, 59.1% {+-} 6.6%, and 52.3% {+-} 6.2%; rectum: 76.3% {+-} 2.5%, 70.2% {+-} 3.3%, and 66.3% {+-} 3.8%. There was no significant difference between D90 and V100 when stratified by prostate size. Conclusions: HDR brachytherapy allows the physician to consistently achieve complete prostate target coverage and maintain normal tissue dose constraints for organs at risk over a wide range of target volumes.

  15. Medication error - Inadvertent high dose intradermal cloxacillin induced skin necrosis

    Directory of Open Access Journals (Sweden)

    Adithan Surendiran

    2012-01-01

    Full Text Available Medication error is one of the important causes of preventable adverse drug reactions. It can occur in the form of administration of a wrong drug, in the wrong dose, to the wrong patient, in an unsuitable dosage form, for the wrong duration or by using an inappropriate route of administration. Intradermal skin testing for cloxacillin hypersensitivity is done at low doses to check for drug allergy. In this report, three patients were given 50 times higher dose of cloxacillin than recommended for skin testing, resulting in pain and necrosis at the site of injection. The error occurred due to wrong dilution of the drug as done by a nursing intern. Some reasons for this could be overtime working, under trained staff, unsupervised nursing interns, complicated and unclear protocols, interpersonal communication gap between health care professionals and also poor availability of ideal resources. Pharmacovigilance centers must alert health care professionals about the significance of reporting medication errors through bulletins and journals.

  16. ``In Vivo'' Dosimetry in High Dose Rate Brachytherapy for Cervical Cancer Treatments

    Science.gov (United States)

    González-Azcorra, S. A.; Mota-García, A.; Poitevín-Chacón, M. A.; Santamaría-Torruco, B. J.; Rodríguez-Ponce, M.; Herrera-Martínez, F. P.; Gamboa de Buen, I.; Ruíz-Trejo, C.; Buenfil, A. E.

    2008-08-01

    In this prospective study, rectal dose was measured "in vivo" using TLD-100 crystals (3×3×1 mm3), and it has been compared to the prescribed dose. Measurements were performed in patients with cervical cancer classified in FIGO stages IB-IIIB and treated with high dose rate brachytherapy (HDR BT) at the Instituto Nacional de Cancerología (INCan).

  17. Solid bioneedle-delivered influenza vaccines are highly thermostable and induce both humoral and cellular immune responses.

    Directory of Open Access Journals (Sweden)

    Peter C Soema

    Full Text Available The potential of bioneedles to deliver influenza vaccines was investigated. Four influenza vaccine formulations were screened to determine the optimal formulation for use with bioneedles. The stability of the formulations after freeze-drying was checked to predict the stability of the influenza vaccines in the bioneedles. Subunit, split, virosomal and whole inactivated influenza (WIV vaccine were formulated and lyophilized in bioneedles, and subsequently administered to C57BL/6 mice. Humoral and cellular immune responses were assessed after vaccination. The thermostability of lyophilized vaccines was determined after one-month storage at elevated temperatures. Bioneedle influenza vaccines induced HI titers that are comparable to those induced by intramuscular WIV vaccination. Delivery by bioneedles did not alter the type of immune response induced by the influenza vaccines. Stability studies showed that lyophilized influenza vaccines have superior thermostability compared to conventional liquid vaccines, and remained stable after one-month storage at 60°C. Influenza vaccines delivered by bioneedles are a viable alternative to conventional liquid influenza vaccines. WIV was determined to be the most potent vaccine formulation for administration by bioneedles. Lyophilized influenza vaccines in bioneedles are independent of a cold-chain, due to their increased thermostability, which makes distribution and stockpiling easier.

  18. Pharmacodynamic effects of standard dose prasugrel versus high dose clopidogrel in non-diabetic obese patients with coronary artery disease.

    Science.gov (United States)

    Darlington, Andrew; Tello-Montoliu, Antonio; Rollini, Fabiana; Ueno, Masafumi; Ferreiro, José Luis; Patel, Ronakkumar; Desai, Bhaloo; Guzman, Luis A; Bass, Theodore A; Angiolillo, Dominick J

    2014-02-01

    Increased body weight is independently associated with impaired clopidogrel pharmacodynamic (PD) response. Prasugrel has more potent PD effects compared with clopidogrel, although its PD effects in obese patients are unknown. The aim of this prospective, randomised, study was to compare the PD effects of standard-dose prasugrel [60 mg loading dose (LD)/10 mg daily maintenance dose (MD)] with high-dose clopidogrel (900 mg LD/150 mg daily MD) in non-diabetic obese [body mass index (BMI) ≥30 kg/m²] patients, with coronary artery disease (CAD) on aspirin therapy. PD assessments (baseline, 2 hours post-LD and 6 ± 2 days after MD) were conducted using four platelet function assays, and the platelet reactivity index (PRI) assessed by VASP was used for sample size estimation. A total of 42 patients with a BMI of 36.42 ± 5.6 kg/m² completed the study. There were no differences in baseline PD measures between groups. At 2 hours post-LD, prasugrel was associated with lower PRI compared with clopidogrel (24.3 ± 5.5 vs 58.7 ± 5.7, p≤0.001), with consistent findings for all assays. At one-week, PRI values on prasugrel MD were lower than clopidogrel MD without reaching statistical significance (34.7 ± 5.8 vs 42.9 ± 5.8, p=0.32), with consistent findings for all assays. Accordingly, rates of high on-treatment platelet reactivity were markedly reduced after prasugrel LD, but not after MD. In conclusion, in non-diabetic obese patients with CAD, standard prasugrel dosing achieved more potent PD effects than high-dose clopidogrel in the acute phase of treatment, but this was not sustained during maintenance phase treatment. Whether an intensified prasugrel regimen is required in obese patients warrants investigation.

  19. Treatment of advanced soft-tissue sarcomas using a combined strategy of high-dose ifosfamide, high-dose doxorubicin and salvage therapies.

    Science.gov (United States)

    Leyvraz, S; Herrmann, R; Guillou, L; Honegger, H P; Christinat, A; Fey, M F; Sessa, C; Wernli, M; Cerny, T; Dietrich, D; Pestalozzi, B

    2006-11-20

    Having determined in a phase I study the maximum tolerated dose of high-dose ifosfamide combined with high-dose doxorubicin, we now report the long-term results of a phase II trial in advanced soft-tissue sarcomas. Forty-six patients with locally advanced or metastatic soft-tissue sarcomas were included, with age or =3 neutropenia in 59%, thrombopenia in 39% and anaemia in 27% of cycles. Three patients experienced grade 3 neurotoxicity and one patient died of septic shock. This high-dose regimen is toxic but nonetheless feasible in multicentre settings in non elderly patients with good performance status. A high response rate was obtained. Prolonged survival was mainly a function of salvage therapies.

  20. Isoniazid overdose treated with high-dose pyridoxine.

    Science.gov (United States)

    Yarbrough, B E; Wood, J P

    1983-05-01

    Large doses of pyridoxine recently have been shown to prevent the seizures and acidosis caused by ingestion of more than two to three grams of isoniazid. We present three cases of massive isoniazid ingestion, producing seizures and acidosis, that were treated successfully by administration of one gram of pyridoxine intravenously for each gram of isoniazid ingested.

  1. High dose rate vaginal brachytherapy in endometrial cancer after surgery; Curietherapie postoperatoire du fond vaginal de haut debit de dose dans le cancer endometrial

    Energy Technology Data Exchange (ETDEWEB)

    Moreau-Claeys, M.V.; Brunaud, C.; Hoffstetter, S.; Buchheit, I.; Peiffert, D. [Departement de curietherapie, centre Alexis-Vautrin, avenue de Bourgogne, 54511 Vandoeuvre-les-Nancy (France)

    2011-06-15

    Purpose. - This study aimed at analyzing the evolution and type of recurrence in patients treated for stage I endometrial carcinomas, in order to define the respective roles of adjuvant radiotherapy and brachytherapy. Patients and methods. - This mono-centric retrospective study was conducted at Centre Alexis-Vautrin, Nancy, France, between January 1995 and December 2000 on all the patients surgically treated for an endometrial cancer, and then treated with high dose rate vaginal brachytherapy. The brachytherapy was delivered in two or three fractions of 7 Gy at 5 mm from the applicator. Results. - In the good prognosis group, the specific and overall survivals at 5 years were respectively 96.5 and 94.2% with no local recurrence demonstrated. In the intermediate prognostic group, the specific and overall survivals at 5 years were respectively 88 and 85%, with six locoregional recurrences observed among those who did not undergo lymphadenectomy; the overall survival at 5 years was significantly decreased in the absence of external radiation. In the group of poor prognosis (stages II and III), the specific survival at 5 years was respectively 72.8 and 67 %, and the overall survival at 5 years 66.7 and 56.4%. Conclusion. - Results for local control and survival as well as for tolerance were good. So we have decided to deliver high rate brachytherapy for all intermediate or poor prognosis patients and we have abandoned pelvic radiotherapy for good prognosis tumours (stages IA: no myometrium invasion with grade 3 and >50% of myometrium invasion with grades 1 and 2), whatever the lymph nodes surgery they had. We now propose pelvic radiotherapy only for intermediate prognosis tumours (such as IA > 50% of myometrium invasion with grade 3 and IB stages), if patients did not have any lymphatic surgery, or for bad prognosis tumours. (authors)

  2. Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

    Directory of Open Access Journals (Sweden)

    Seyed Mohsen Hosseini Daghigh

    2012-03-01

    Full Text Available Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phantom was built in order to be inserted by various sizes of esophageal applicators. EDR2 films were placed at 33 mm from Ir-192 source and irradiated with 1.5 Gy after planning using treatment planning system for all applicators. Results The results of film dosimetry in reference point for 6, 8, 10, and 20 mm applicators were 1.54, 1.53, 1.48, and 1.50 Gy, respectively. The difference between practical and treatment planning system results was 0.023 Gy (

  3. Irradiation dose and temperature dependence of fracture toughness in high dose HT9 steel from the fuel duct of FFTF

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Thak Sang; Toloczko, Mychailo B.; Saleh, Tarik A.; Maloy, Stuart A.

    2013-01-14

    To expand the knowledge base for fast reactor core materials, fracture toughness has been evaluated for high dose HT9 steel using miniature disk compact tension (DCT) specimens. The HT9 steel DCT specimens were machined from the ACO-3 fuel duct of the Fast Flux Test Facility (FFTF), which achieved high doses in the range of 3–148 dpa at 378–504 C. The static fracture resistance (J-R) tests have been performed in a servohydraulic testing machine in vacuum at selected temperatures including room temperature, 200 C, and each irradiation temperature. Brittle fracture with a low toughness less than 50 MPa pm occurred in room temperature tests when irradiation temperature was below 400 C, while ductile fracture with stable crack growth was observed when irradiation temperature was higher. No fracture toughness less than 100 MPa pm was measured when the irradiation temperature was above 430 C. It was shown that the influence of irradiation temperature was dominant in fracture toughness while the irradiation dose has only limited influence over the wide dose range 3–148 dpa. A slow decrease of fracture toughness with test temperature above room temperature was observed for the nonirradiated and high temperature (>430 *C) irradiation cases, which indicates that the ductile–brittle transition temperatures (DBTTs) in those conditions are lower than room temperature. A comparison with the collection of existing data confirmed the dominance of irradiation temperature in the fracture toughness of HT9 steels.

  4. A Real World Report on Intravenous High-Dose and Non-High-Dose Proton-Pump Inhibitors Therapy in Patients with Endoscopically Treated High-Risk Peptic Ulcer Bleeding

    Directory of Open Access Journals (Sweden)

    Lung-Sheng Lu

    2012-01-01

    Full Text Available Background and Study Aims. The optimal dose of intravenous proton-pump inhibitor (PPI therapy for the prevention of peptic ulcer (PU rebleeding remains controversial. This study aimed to understand the real world experiences in prescribing high-dose PPI and non-high-dose PPI for preventing rebleeding after endoscopic treatment of high-risk PU. Patients and Methods. A total of 220 subjects who received high-dose and non-high-dose pantoprazole for confirmed acute PU bleeding that were successfully treated endoscopically were enrolled. They were divided into rebleeding (n=177 and non-rebleeding groups (n=43. Randomized matching of the treatment-control group was performed. Patients were randomly selected for non-high-dose and high-dose PPI groups (n=44 in each group. Results. Univariate analysis showed, significant variables related to rebleeding were female, higher creatinine levels, and higher Rockall scores (≧6. Before case-control matching, the high-dose PPI group had higher creatinine level, higher percentage of shock at presentation, and higher Rockall scores. After randomized treatment-control matching, no statistical differences were observed for rebleeding rates between the high-dose and non-high-dose groups after case-control matching. Conclusion. This study suggests that intravenous high-dose pantoprazole may not be superior to non-high-dose regimen in reducing rebleeding in high-risk peptic ulcer bleeding after successful endoscopic therapy.

  5. Moles of a Substance per Cell Is a Highly Informative Dosing Metric in Cell Culture.

    Science.gov (United States)

    Doskey, Claire M; van 't Erve, Thomas J; Wagner, Brett A; Buettner, Garry R

    2015-01-01

    The biological consequences upon exposure of cells in culture to a dose of xenobiotic are not only dependent on biological variables, but also the physical aspects of experiments e.g. cell number and media volume. Dependence on physical aspects is often overlooked due to the unrecognized ambiguity in the dominant metric used to express exposure, i.e. initial concentration of xenobiotic delivered to the culture medium over the cells. We hypothesize that for many xenobiotics, specifying dose as moles per cell will reduce this ambiguity. Dose as moles per cell can also provide additional information not easily obtainable with traditional dosing metrics. Here, 1,4-benzoquinone and oligomycin A are used as model compounds to investigate moles per cell as an informative dosing metric. Mechanistic insight into reactions with intracellular molecules, differences between sequential and bolus addition of xenobiotic and the influence of cell volume and protein content on toxicity are also investigated. When the dose of 1,4-benzoquinone or oligomycin A was specified as moles per cell, toxicity was independent of the physical conditions used (number of cells, volume of medium). When using moles per cell as a dose-metric, direct quantitative comparisons can be made between biochemical or biological endpoints and the dose of xenobiotic applied. For example, the toxicity of 1,4-benzoquinone correlated inversely with intracellular volume for all five cell lines exposed (C6, MDA-MB231, A549, MIA PaCa-2, and HepG2). Moles per cell is a useful and informative dosing metric in cell culture. This dosing metric is a scalable parameter that: can reduce ambiguity between experiments having different physical conditions; provides additional mechanistic information; allows direct comparison between different cells; affords a more uniform platform for experimental design; addresses the important issue of repeatability of experimental results, and could increase the translatability of

  6. Moles of a Substance per Cell Is a Highly Informative Dosing Metric in Cell Culture.

    Directory of Open Access Journals (Sweden)

    Claire M Doskey

    Full Text Available The biological consequences upon exposure of cells in culture to a dose of xenobiotic are not only dependent on biological variables, but also the physical aspects of experiments e.g. cell number and media volume. Dependence on physical aspects is often overlooked due to the unrecognized ambiguity in the dominant metric used to express exposure, i.e. initial concentration of xenobiotic delivered to the culture medium over the cells. We hypothesize that for many xenobiotics, specifying dose as moles per cell will reduce this ambiguity. Dose as moles per cell can also provide additional information not easily obtainable with traditional dosing metrics.Here, 1,4-benzoquinone and oligomycin A are used as model compounds to investigate moles per cell as an informative dosing metric. Mechanistic insight into reactions with intracellular molecules, differences between sequential and bolus addition of xenobiotic and the influence of cell volume and protein content on toxicity are also investigated.When the dose of 1,4-benzoquinone or oligomycin A was specified as moles per cell, toxicity was independent of the physical conditions used (number of cells, volume of medium. When using moles per cell as a dose-metric, direct quantitative comparisons can be made between biochemical or biological endpoints and the dose of xenobiotic applied. For example, the toxicity of 1,4-benzoquinone correlated inversely with intracellular volume for all five cell lines exposed (C6, MDA-MB231, A549, MIA PaCa-2, and HepG2.Moles per cell is a useful and informative dosing metric in cell culture. This dosing metric is a scalable parameter that: can reduce ambiguity between experiments having different physical conditions; provides additional mechanistic information; allows direct comparison between different cells; affords a more uniform platform for experimental design; addresses the important issue of repeatability of experimental results, and could increase the

  7. Cervical gross tumor volume dose predicts local control using magnetic resonance imaging/diffusion-weighted imaging-guided high-dose-rate and positron emission tomography/computed tomography-guided intensity modulated radiation therapy.

    Science.gov (United States)

    Dyk, Pawel; Jiang, Naomi; Sun, Baozhou; DeWees, Todd A; Fowler, Kathryn J; Narra, Vamsi; Garcia-Ramirez, Jose L; Schwarz, Julie K; Grigsby, Perry W

    2014-11-15

    Magnetic resonance imaging/diffusion weighted-imaging (MRI/DWI)-guided high-dose-rate (HDR) brachytherapy and (18)F-fluorodeoxyglucose (FDG) - positron emission tomography/computed tomography (PET/CT)-guided intensity modulated radiation therapy (IMRT) for the definitive treatment of cervical cancer is a novel treatment technique. The purpose of this study was to report our analysis of dose-volume parameters predicting gross tumor volume (GTV) control. We analyzed the records of 134 patients with International Federation of Gynecology and Obstetrics stages IB1-IVB cervical cancer treated with combined MRI-guided HDR and IMRT from July 2009 to July 2011. IMRT was targeted to the metabolic tumor volume and lymph nodes by use of FDG-PET/CT simulation. The GTV for each HDR fraction was delineated by use of T2-weighted or apparent diffusion coefficient maps from diffusion-weighted sequences. The D100, D90, and Dmean delivered to the GTV from HDR and IMRT were summed to EQD2. One hundred twenty-five patients received all irradiation treatment as planned, and 9 did not complete treatment. All 134 patients are included in this analysis. Treatment failure in the cervix occurred in 24 patients (18.0%). Patients with cervix failures had a lower D100, D90, and Dmean than those who did not experience failure in the cervix. The respective doses to the GTV were 41, 58, and 136 Gy for failures compared with 67, 99, and 236 Gy for those who did not experience failure (PD100, D90, and Dmean doses required for ≥90% local control to be 69, 98, and 260 Gy (P<.001). Total dose delivered to the GTV from combined MRI-guided HDR and PET/CT-guided IMRT is highly correlated with local tumor control. The findings can be directly applied in the clinic for dose adaptation to maximize local control. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Thrust Magnitudes, Rates, and 3-Dimensional Directions Delivered in Simulated Lumbar Spine High-Velocity, Low-Amplitude Manipulation.

    Science.gov (United States)

    Owens, Edward F; Hosek, Ronald S; Mullin, Linda; Dever, Lydia; Sullivan, Stephanie G B; Russell, Brent S

    The purpose of this study was to measure faculty performance of simulated spinal manipulation on a mannequin to help identify teaching standards. We measured 3-dimensional transmitted loads using a force plate mounted in the table. Thrusts were delivered through a compliant, jointed mannequin by faculty members along predefined "listings" as taught in lumbopelvic technique courses. Eleven chiropractic faculty members participated, delivering 9 thrusts at 3 loads (light, moderate, and heavy) along 9 different prone and side-posture listings, totaling 81 thrusts per participant. Single-hand Gonstead-style thrusts had variability in magnitude across participants and loads: light thrusts averaged 365 N (95% confidence interval [CI] 327-402), moderate thrusts 454 N (421-487), and heavy thrusts 682 N (623-740). All faculty members could easily distinguish the loads within their performances, but there was some crossover of load levels between participants. Thrust rates averaged 3.55 N/ms (95% CI 3.29-3.82). The dominant vector of prone thrusts was in the z direction (vertically downward), but side-to-side and inferior-to-superior vector components occurred. Faculty member performance of simulated spinal manipulation indicated that they are able to control the thrust magnitude and rate as well as direction. In this sample, there was significant variability in peak loads between participants, which needs to be considered in student learning standards. These findings may be useful in translating the understanding of force characteristics to the technique teaching lab. Copyright © 2017. Published by Elsevier Inc.

  9. HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

    Energy Technology Data Exchange (ETDEWEB)

    Chibani, Omar, E-mail: omar.chibani@fccc.edu; C-M Ma, Charlie [Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States)

    2014-05-15

    Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR

  10. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6-11 years-old than cumulative high doses of inhaled terbutaline

    DEFF Research Database (Denmark)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören

    2004-01-01

    OBJECTIVES: To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. METHODS: Twenty boys and girls (6-11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxis......) 4.5 microg (F4.5) or terbutaline (Bricanyl) 500 microg (T500) were inhaled cumulatively via a dry powder inhaler (Turbuhaler) over 1 h (three patients) or 2.5 h (17 patients) and compared to a day of no treatment, in a randomised, double-blind (active treatments only), crossover trial. Blood...... pressure (BP), ECG, plasma potassium, glucose, lactate, and adverse events were monitored up to 10 h to assess tolerability and relative systemic dose potency. RESULTS: Formoterol and terbutaline had significant beta2-adrenergic effects on most outcomes. Apart from the effect on systolic BP, QRS duration...

  11. Dose dense (CEOP-14) vs dose dense and rituximab (CEOP-14 +R) in high-risk diffuse large cell lymphoma.

    Science.gov (United States)

    Avilés, Agustin; Nambo, María J; Neri, Natividad; Cleto, Sergio; Castañeda, Claudia; Huerta-Guzmàn, Judith; Murillo, Edgar; Contreras, Margarita; Talavera, Alejandra; González, Martha

    2007-01-01

    To assess efficacy and toxicity of rituximab and dose chemotherapy in high-risk diffuse large cell lymphoma, we conducted a controlled clinical trial to assess efficacy and toxicity of a dose-dense regimen CEOP- 14 (cyclophosphamide, epirubicin, vincristine, and prednisone every 14 d) compared to CEOP-14 plus rituximab. One hundred and ninety-six patients were randomized to received CEOP-rituximab (cyclophosphamide 1500 mg/m2, epirubicin 120 mg/m2, vincristine, and prednisone at standard dose and rituximab at 375 mg/m2) compared with the same chemotherapy administered every 14 d (CEOP-14). In an intent-to-treat analysis all patients were available for efficacy and toxicity. Complete response in CEOP-14 was observed in 73 cases (74%) and in 75 patients (76%) in the CEOP-R regimen (76%) (p = 0.8). With a median follow-up of 53.4 mo, median has not been reached in time to tumor-progression (TTP) and overall survival (OS). Actuarial curves at 5 yr showed that TTP and OS in patients treated with CEOP-R were 74% and 67%, respectively, that were not statistical different when compared to CEOP-14, 72% and 65%, respectively (p = 0.8). Acute toxicity was mild and well tolerated. The use of a dense-dose regimen is useful and well tolerated in patients with very high risk diffuse large cell lymphoma. The addition of rituximab did not improve outcome in these setting of patients.

  12. High-dose lidocaine does not affect defibrillation efficacy: implications for defibrillation mechanisms.

    Science.gov (United States)

    Ujhelyi, M R; Sims, J J; Miller, A W

    1998-04-01

    This study assessed the effect of low (10 mg.kg-1.h-1) and very high (18 mg.kg-1.h-1) doses of lidocaine on defibrillation energy requirements (DER) to relate changes in indexes of sodium-channel blockade with changes in DER values using a dose-response study design. In group 1 (control; n = 6 pigs), DER values were determined at baseline and during treatment with 5% dextrose in water (D5W) and with D5W added to D5W. In group 2 (n = 7), DER values were determined at baseline and during treatment with low-dose lidocaine followed by high-dose lidocaine. In group 3 (n = 3), DER values were determined at baseline and high-dose lidocaine. Group 3 controlled for the order of lidocaine treatment with the addition of high-dose lidocaine after baseline. DER values in group 1 did not change during D5W. In group 2, low-dose lidocaine increased DER values by 51% (P = 0.01), whereas high-dose lidocaine added to low-dose lidocaine reduced DER values back to within 6% of baseline values (P = 0.02, low dose vs. high dose). DER values during high-dose lidocaine in group 3 also remained near baseline values (16.2 +/- 2.7 to 12.9 +/- 2.7 J), demonstrating that treatment order had no impact on group 2. Progressive sodium-channel blockade was evident as incremental reduction in ventricular conduction velocity as the lidocaine dose increased. Lidocaine also significantly increased ventricular fibrillation cycle length as the lidocaine dose increased. However, the greatest increase in DER occurred when ventricular fibrillation cycle length was minimally affected, demonstrating a negative correlation (P = 0.04). In summary, lidocaine has an inverted U-shaped DER dose-response curve. At very high lidocaine doses, DER values are similar to baseline and tend to decrease rather than increase. Increased refractoriness during ventricular fibrillation may be the electrophysiological mechanism by which high-dose lidocaine limits the adverse effects that low-dose lidocaine has on DER values

  13. High Dose Vaginal Misoprostol Versus Concentrated Oxytocin + Low Dose Vaginal Misoprostol for Mid-Trimester Labor Induction: A Randomized Trial

    Science.gov (United States)

    Nuthalapaty, Francis S.; Ramsey, Patrick S.; Biggio, Joseph R.; Owen, John

    2013-01-01

    Objective To compare the efficacy and side effects of a high-dose vaginal misoprostol regimen to concentrated intravenous oxytocin plus low-dose vaginal misoprostol for mid-trimester labor induction. Study Design Women at 14-24 weeks, with obstetric or fetal indications for delivery and no prior cesarean, were randomly assigned to receive either vaginal misoprostol 600 μg ×1, then 400 μg q 4 hr × 5 (Group 1) or escalating-dose concentrated oxytocin infusions (277-1667 mU/min) plus vaginal misoprostol 400 μg × 1, then 200 μg q 6 hr × 2, then 100 μg × 1 (Group 2). Analysis was by intent to treat. Primary outcomes were live birth rate and induction-to-delivery interval. Results The intended sample size was 70 women per group; however, the trial was terminated at the initial interim analysis due to a highly significant difference in one of the primary study outcomes. Twenty women were assigned to Group 1 and 18 were assigned to the Group 2. Median induction-to-delivery interval was significantly shorter in Group 1 (12 hr, range 4 - 44 hr) versus Group 2 (18 hr, range 7 - 36 hr; p=0.01). Induction success rate at 12 hours was significantly higher in the Group 1 (60%), compared to Group 2 (22%, p=.02). No significant difference was noted in the live birth rate between Group 1 and 2 (13%, 0%, p = 0.16). The incidence of retained placenta requiring curettage, chorioamnionitis, intrapartum fever, nausea, emesis, and diarrhea were similar between both groups. Conclusion Compared to concentrated oxytocin plus low-dose vaginal misoprostol, high-dose vaginal misoprostol significantly shortens mid-trimester labor inductions. PMID:16157113

  14. Predictors of Toxicity After Image-guided High-dose-rate Interstitial Brachytherapy for Gynecologic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Larissa J. [Department of Radiation Oncology, Brigham and Women' s Hospital and Dana-Farber Cancer Institute, Harvard Medical School, Boston, Massachusetts (United States); Viswanathan, Akila N., E-mail: aviswanathan@lroc.harvard.edu [Department of Radiation Oncology, Brigham and Women' s Hospital and Dana-Farber Cancer Institute, Harvard Medical School, Boston, Massachusetts (United States)

    2012-12-01

    Purpose: To identify predictors of grade 3-4 complications and grade 2-4 rectal toxicity after three-dimensional image-guided high-dose-rate (HDR) interstitial brachytherapy for gynecologic cancer. Methods and Materials: Records were reviewed for 51 women (22 with primary disease and 29 with recurrence) treated with HDR interstitial brachytherapy. A single interstitial insertion was performed with image guidance by computed tomography (n = 43) or magnetic resonance imaging (n = 8). The median delivered dose in equivalent 2-Gy fractions was 72.0 Gy (45 Gy for external-beam radiation therapy and 24 Gy for brachytherapy). Toxicity was reported according to the Common Toxicity Criteria for Adverse Events. Actuarial toxicity estimates were calculated by the Kaplan-Meier method. Results: At diagnosis, the median patient age was 62 years and the median tumor size was 3.8 cm. The median D90 and V100 were 71.4 Gy and 89.5%; the median D2cc for the bladder, rectum, and sigmoid were 64.6 Gy, 61.0 Gy, and 52.7 Gy, respectively. The actuarial rates of all grade 3-4 complications at 2 years were 20% gastrointestinal, 9% vaginal, 6% skin, 3% musculoskeletal, and 2% lymphatic. There were no grade 3-4 genitourinary complications and no grade 5 toxicities. Grade 2-4 rectal toxicity was observed in 10 patients, and grade 3-4 complications in 4; all cases were proctitis with the exception of 1 rectal fistula. D2cc for rectum was higher for patients with grade 2-4 (68 Gy vs 57 Gy for grade 0-1, P=.03) and grade 3-4 (73 Gy vs 58 Gy for grade 0-2, P=.02) rectal toxicity. The estimated dose that resulted in a 10% risk of grade 2-4 rectal toxicity was 61.8 Gy (95% confidence interval, 51.5-72.2 Gy). Discussion: Image-guided HDR interstitial brachytherapy results in acceptable toxicity for women with primary or recurrent gynecologic cancer. D2cc for the rectum is a reliable predictor of late rectal complications. Three-dimensional-based treatment planning should be performed to ensure

  15. The effects of high-dose ivermectin regimens on Onchocerca volvulus in onchocerciasis patients.

    Science.gov (United States)

    Awadzi, K; Attah, S K; Addy, E T; Opoku, N O; Quartey, B T

    1999-01-01

    Ivermectin, at the standard dose of 150 micrograms/kg bodyweight, does not kill the adult worms of Onchocerca volvulus and does not disrupt embryogenesis or spermatogenesis. Repeated standard doses, if maintained, arrest microfilarial production but result in only a mild-to-modest macrofilaricidal effect. We investigated whether high doses would effectively kill the adult worms, and whether cessation of microfilarial production could be reproduced by an equivalent, single, high dose. One hundred men participated in a double-blind placebo-controlled trial and received increasing doses of ivermectin from 150 micrograms/kg to 1600 micrograms/kg bodyweight. Nodules were excised at day 180 and examined by histopathology. Total doses of ivermectin up to 1600 micrograms/kg were not significantly more effective than 150 micrograms/kg. Moreover, they did not reproduce the marked inhibitory effects of the repeat standard-dose regimens on embryogenesis, nor the modest effect on adult worm viability, at comparable total doses. These effects may be functions of multiplicities of dosages rather than of the total dose. Our findings also suggest that repeated high-dose regimens are unlikely to be more effective than a similar number of 150 micrograms/kg doses. This deficiency of ivermectin requires that the search for macrofilaricides remains a top priority.

  16. Effects of low dose gamma radiation on the early growth of red pepper and the resistance to subsquent high dose of radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. S.; Baek, M. H.; Kim, D. H.; Lee, Y. K. [KAERI, Taejon (Korea, Republic of); Lee, Y. B. [Chungnam National Univ., Taejon (Korea, Republic of)

    2001-05-01

    Red pepper (capsicum annuum L. cv. Jokwang and cv. Johong) seeds were irradiated with the dose of 0{approx}50 Gy to investigated the effect of the low dose gamma radiation on the early growth and resistance to subsequent high dose of radiation. The effect of the low dose gamma radiation on the early growth and resistance to subsequenct high dose of radiation were enhanced in Johong cultivar but not in Jokwang cultivar. Germination rate and early growth of Johong cultivar were noticeably increased at 4 Gy-, 8 Gy- and 20 Gy irradiation group. Resistance to subsequent high dose of radiation of Johong cultivar were increased at almost all of the low dose irradiation group. Especially it was highest at 4 Gy irradiation group. The carotenoid contents and enzyme activity on the resistance to subsequent high dose of radiation of Johong cultivar were increased at the 4 Gy and 8 Gy irradiation group.

  17. High dose of ascorbic acid induces cell death in mesothelioma cells.

    Science.gov (United States)

    Takemura, Yukitoshi; Satoh, Motohiko; Satoh, Kiyotoshi; Hamada, Hironobu; Sekido, Yoshitaka; Kubota, Shunichiro

    2010-04-02

    Malignant mesothelioma is an asbestos-related fatal disease with no effective cure. Recently, high dose of ascorbate in cancer treatment has been reexamined. We studied whether high dose of ascorbic acid induced cell death of four human mesothelioma cell lines. High dose of ascorbic acid induced cell death of all mesothelioma cell lines in a dose-dependent manner. We further clarified the cell killing mechanism that ascorbic acid induced reactive oxygen species and impaired mitochondrial membrane potential. In vivo experiment, intravenous administration of ascorbic acid significantly decreased the growth rate of mesothelioma tumor inoculated in mice. These data suggest that ascorbic acid may have benefits for patients with mesothelioma.

  18. Randomized Trial Comparing Conventional-Dose With High-Dose Conformal Radiation Therapy in Early-Stage Adenocarcinoma of the Prostate: Long-Term Results From Proton Radiation Oncology Group/American College of Radiology 95-09

    Science.gov (United States)

    Zietman, Anthony L.; Bae, Kyounghwa; Slater, Jerry D.; Shipley, William U.; Efstathiou, Jason A.; Coen, John J.; Bush, David A.; Lunt, Margie; Spiegel, Daphna Y.; Skowronski, Rafi; Jabola, B. Rodney; Rossi, Carl J.

    2010-01-01

    Purpose To test the hypothesis that increasing radiation dose delivered to men with early-stage prostate cancer improves clinical outcomes. Patients and Methods Men with T1b-T2b prostate cancer and prostate-specific antigen ≤ 15 ng/mL were randomly assigned to a total dose of either 70.2 Gray equivalents (GyE; conventional) or 79.2 GyE (high). No patient received androgen suppression therapy with radiation. Local failure (LF), biochemical failure (BF), and overall survival (OS) were outcomes. Results A total of 393 men were randomly assigned, and median follow-up was 8.9 years. Men receiving high-dose radiation therapy were significantly less likely to have LF, with a hazard ratio of 0.57. The 10-year American Society for Therapeutic Radiology and Oncology BF rates were 32.4% for conventional-dose and 16.7% for high-dose radiation therapy (P < .0001). This difference held when only those with low-risk disease (n = 227; 58% of total) were examined: 28.2% for conventional and 7.1% for high dose (P < .0001). There was a strong trend in the same direction for the intermediate-risk patients (n = 144; 37% of total; 42.1% v 30.4%, P = .06). Eleven percent of patients subsequently required androgen deprivation for recurrence after conventional dose compared with 6% after high dose (P = .047). There remains no difference in OS rates between the treatment arms (78.4% v 83.4%; P = .41). Two percent of patients in both arms experienced late grade ≥ 3 genitourinary toxicity, and 1% of patients in the high-dose arm experienced late grade ≥ 3 GI toxicity. Conclusion This randomized controlled trial shows superior long-term cancer control for men with localized prostate cancer receiving high-dose versus conventional-dose radiation. This was achieved without an increase in grade ≥ 3 late urinary or rectal morbidity. PMID:20124169

  19. Significance and Prospect of Delivering Wind Power through Ultra-High Voltage%再论特高压带送风电的意义与前景

    Institute of Scientific and Technical Information of China (English)

    杨建设

    2013-01-01

      以一个工程案例探讨了特高压输电工程带送风电的巨大潜力,又引用一项研究成果说明了特高压带送风电的广阔应用前景,指出应该及早制定运用原则和政策措施,扎实推进相关工作。%It is discussed as a case of the huge potential about delivering wind power through ultra-high voltage (UHV) transmission project. A broad application prospect about delivering wind power through UHV is also illustrated by citing a study. It is pointed out that principles and measures should be formulated in time, and related work must be promoted strongly.

  20. Ceramic Matrix Composites Performances Under High Gamma Radiation Doses

    Science.gov (United States)

    Cemmi, A.; Baccaro, S.; Fiore, S.; Gislon, P.; Serra, E.; Fassina, S.; Ferrari, E.; Ghisolfi, E.

    2014-06-01

    Ceramic matrix composites reinforced by continuous ceramic fibers (CMCs) represent a class of advanced materials developed for applications in automotive, aerospace, nuclear fusion reactors and in other specific systems for harsh environments. In the present work, the silicon carbide/silicon carbide (SiCf/SiC) composites, manufactured by Chemical Vapour Infiltration process at FN S.p.A. plant, have been evaluated in term of gamma radiation hardness at three different absorbed doses (up to around 3MGy). Samples behavior has been investigated before and after irradiation by means of mechanical tests (flexural strength) and by surface and structural analyses (X-ray diffraction, SEM, FTIR-ATR, EPR).

  1. Single high-dose pyridoxine treatment for isoniazid overdose.

    Science.gov (United States)

    Wason, S; Lacouture, P G; Lovejoy, F H

    1981-09-04

    We treated five isoniazid-overdosed patients each with a single dose of pyridoxine hydrochloride equivalent to the gram amount of isoniazid ingested and compared their outcome with that of 41 patients from the literature who received little or no pyridoxine. Recurrent seizures occurred in 60% of patients who had received no pyridoxine vs 0% in our patients. Metabolic acidosis resolved in our cases but was refractory in the literature cases. In our cases, coma lightened more rapidly and was of shorter duration as compared with that in the literature cases (mean, seven hours vs 24 hours). No adverse effects of pyridoxine were seen in our patients.

  2. 360-degree 3D transvaginal ultrasound system for high-dose-rate interstitial gynaecological brachytherapy needle guidance

    Science.gov (United States)

    Rodgers, Jessica R.; Surry, Kathleen; D'Souza, David; Leung, Eric; Fenster, Aaron

    2017-03-01

    Treatment for gynaecological cancers often includes brachytherapy; in particular, in high-dose-rate (HDR) interstitial brachytherapy, hollow needles are inserted into the tumour and surrounding area through a template in order to deliver the radiation dose. Currently, there is no standard modality for visualizing needles intra-operatively, despite the need for precise needle placement in order to deliver the optimal dose and avoid nearby organs, including the bladder and rectum. While three-dimensional (3D) transrectal ultrasound (TRUS) imaging has been proposed for 3D intra-operative needle guidance, anterior needles tend to be obscured by shadowing created by the template's vaginal cylinder. We have developed a 360-degree 3D transvaginal ultrasound (TVUS) system that uses a conventional two-dimensional side-fire TRUS probe rotated inside a hollow vaginal cylinder made from a sonolucent plastic (TPX). The system was validated using grid and sphere phantoms in order to test the geometric accuracy of the distance and volumetric measurements in the reconstructed image. To test the potential for visualizing needles, an agar phantom mimicking the geometry of the female pelvis was used. Needles were inserted into the phantom and then imaged using the 3D TVUS system. The needle trajectories and tip positions in the 3D TVUS scan were compared to their expected values and the needle tracks visualized in magnetic resonance images. Based on this initial study, 360-degree 3D TVUS imaging through a sonolucent vaginal cylinder is a feasible technique for intra-operatively visualizing needles during HDR interstitial gynaecological brachytherapy.

  3. A hybrid evolutionary algorithm for multi-objective anatomy-based dose optimization in high-dose-rate brachytherapy.

    Science.gov (United States)

    Lahanas, M; Baltas, D; Zamboglou, N

    2003-02-07

    Multiple objectives must be considered in anatomy-based dose optimization for high-dose-rate brachytherapy and a large number of parameters must be optimized to satisfy often competing objectives. For objectives expressed solely in terms of dose variances, deterministic gradient-based algorithms can be applied and a weighted sum approach is able to produce a representative set of non-dominated solutions. As the number of objectives increases, or non-convex objectives are used, local minima can be present and deterministic or stochastic algorithms such as simulated annealing either cannot be used or are not efficient. In this case we employ a modified hybrid version of the multi-objective optimization algorithm NSGA-II. This, in combination with the deterministic optimization algorithm, produces a representative sample of the Pareto set. This algorithm can be used with any kind of objectives, including non-convex, and does not require artificial importance factors. A representation of the trade-off surface can be obtained with more than 1000 non-dominated solutions in 2-5 min. An analysis of the solutions provides information on the possibilities available using these objectives. Simple decision making tools allow the selection of a solution that provides a best fit for the clinical goals. We show an example with a prostate implant and compare results obtained by variance and dose-volume histogram (DVH) based objectives.

  4. A hybrid evolutionary algorithm for multi-objective anatomy-based dose optimization in high-dose-rate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Lahanas, M [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach, 63069 Offenbach (Germany); Baltas, D [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach, 63069 Offenbach (Germany); Zamboglou, N [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach, 63069 Offenbach (Germany)

    2003-02-07

    Multiple objectives must be considered in anatomy-based dose optimization for high-dose-rate brachytherapy and a large number of parameters must be optimized to satisfy often competing objectives. For objectives expressed solely in terms of dose variances, deterministic gradient-based algorithms can be applied and a weighted sum approach is able to produce a representative set of non-dominated solutions. As the number of objectives increases, or non-convex objectives are used, local minima can be present and deterministic or stochastic algorithms such as simulated annealing either cannot be used or are not efficient. In this case we employ a modified hybrid version of the multi-objective optimization algorithm NSGA-II. This, in combination with the deterministic optimization algorithm, produces a representative sample of the Pareto set. This algorithm can be used with any kind of objectives, including non-convex, and does not require artificial importance factors. A representation of the trade-off surface can be obtained with more than 1000 non-dominated solutions in 2-5 min. An analysis of the solutions provides information on the possibilities available using these objectives. Simple decision making tools allow the selection of a solution that provides a best fit for the clinical goals. We show an example with a prostate implant and compare results obtained by variance and dose-volume histogram (DVH) based objectives.

  5. Radiation Sialadenitis Induced by High-dose Radioactive Iodine Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Shin Young; Lee, Jaetae [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2010-06-15

    Radioactive iodine ({sup 131}I) is accumulated in the thyroid tissue and plays an important role in the treatment of differentiated papillary and follicular cancers after thyroidectomy. Simultaneously, {sup 131}I is concentrated in the salivary glands and secreted into the saliva. Dose-related damage to the salivary parenchyma results from the {sup 131}I irradiation. Salivary gland swelling and pain, usually involving the parotid, can be seen. The symptoms may develop immediately after a therapeutic dose of {sup 131}I and/or months later and progress in intensity with time. In conjunction with the radiation sialadenitis, secondary complications reported include xerostomia, taste alterations, infection, increases in caries, facial nerve involvement, candidiasis, and neoplasia. Prevention of {sup 131}I sialadenitis may involve the use of sialogogic agents to hasten the transit time of the radioactive iodine through the salivary glands. However, studies are not available to delineate the efficacy of this approach. Treatment of the varied complications that may develop encompass numerous approaches and include gland massage, sialogogic agents, duct probing, antibiotics, mouthwashes, good oral hygiene, and adequate hydration. Recently interventional sialoendoscopy has been introduced an effective tool for the management of patients with {sup 131}I-induced sialadenitis that is unresponsive to medical treatment.

  6. Elimination of ascorbic acid after high-dose infusion in prostate cancer patients

    DEFF Research Database (Denmark)

    Nielsen, Torben Kjær; Højgaard, Martin; Andersen, Jon Thor Trærup

    2015-01-01

    Treatment with high-dose intravenous (IV) ascorbic acid (AA) is used in complementary and alternative medicine for various conditions including cancer. Cytotoxicity to cancer cell lines has been observed with millimolar concentrations of AA. Little is known about the pharmacokinetics of high dose...

  7. High daily doses of benzodiazepines among Quebec seniors: prevalence and correlates

    Directory of Open Access Journals (Sweden)

    Moride Yola

    2001-11-01

    Full Text Available Abstract Background Use of high daily doses of benzodiazepines is generally contraindicated for seniors. While both patient and physician factors may influence the use of high daily doses, previous research on the effect of patient factors has been extremely limited. The objectives of this study were to determine the one year prevalence of use of high daily doses of benzodiazepines, and examine physician and patient correlates of such use among Quebec community-dwelling seniors. Methods Patient information for 1423 community-dwelling Quebec seniors who participated in the Canadian Study of Health and Aging was linked to provincial health insurance administrative data bases containing detailed information on prescriptions received and prescribers. Results The standardized one year period prevalence of use of high daily doses of benzodiazepines was 7.9%. Use of high daily doses was more frequent among younger seniors and those who had reported anxiety during the previous year. Patients without cognitive impairment were more likely to receive high dose prescriptions from general practitioners, while those with cognitive impairment were more likely to receive high dose prescriptions from specialists. Conclusion High dose prescribing appears to be related to both patient and physician factors.

  8. Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions

    Science.gov (United States)

    McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.

    2012-01-01

    Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.

  9. High- and low-dose expectancies as mediators of personality dimensions and alcohol involvement.

    Science.gov (United States)

    Read, Jennifer P; O'Connor, Roisin M

    2006-03-01

    The present study examined the influences of personality dimensions (extraversion, neuroticism) on college alcohol involvement both (1) directly and (2) mediated by positive and negative alcohol expectancies across two imagined (high and low) alcohol doses. Participants (N = 339; 176 women) were regularly drinking college students who completed a questionnaire battery on demographic characteristics, personality, expectancies, and alcohol use and problems. Structural equation modeling analysis of low- and high-dose models revealed partial support for the Social Learning Theory conceptualization of expectancies as mediators of more distal (personality) influences. Interestingly, patterns of association differed by dose. At high-expectancy doses, positive alcohol expectancies fully mediated the extraversion-use association. At low doses, positive expectancies did not play a critical role. Two distinct pathways from neuroticism to alcohol use were observed: a direct pathway, whereby neuroticism is a protective factor for alcohol use, and an indirect pathway, through positive expectancies, whereby neuroticism is a risk factor. The protective pathway was evident regardless of expectancy doses, whereas the risk pathway was evident only at high doses. Negative expectancies partially mediated the association between neuroticism and alcohol problems at both high- and low-expectancy doses. These data underscore the unique role of both positive and negative expectancies in the association between personality and drinking behavior and point to the importance of considering alcohol dose when assessing expectancies. Findings suggest that it may be beliefs about the effects resulting from heavy (rather than moderate) drinking that may be the active mechanism underlying drinking behavior.

  10. Efficacy of Continuous High Dose Midazolam Infusion in Childhood Refractory Generalized Convulsive Status Epilepticus

    Directory of Open Access Journals (Sweden)

    Afshin Fayyazi

    2011-06-01

    Full Text Available bjeciveProlonged and uncontrolled refractory status epilepticus (SE is a life-threatening medical emergency in children (1,2,3. There is no consensus on the optimal therapy for refractory status epilepticus (1. The aim of this study was to develop a new method for treating patients with refractory status epilepticus.Materials & MethodsTen children with refractory status epilepticus in Mofid Hospital, who did not respond to 10 μg/kg per min of intravenous midazolam, had their dose of midazolam increased to 30 μg/kg per min. All children were monitored for the development of side effects.ResultsTen children with no response to low-dose midazolam were given a higher dose of midazolam, and 5 (50% children had a good response. These patients had significantly different response to high-dose midazolam.One patient in the high-dose midazolam group was intubated and required mechanical ventilation. The duration of stay in the hospital and PICU and on mechanical ventilation in patients with no response to low-dose midazolam following with other drugs was longer than in the high-dose midazolam group.No death occurred in high dose midazolam group.ConclusionHigh-midazolam dose drip infusion is a safe and effective protocol for refractory status epilepticus in children.

  11. High frequency of streptococcal bacteraemia during childhood AML therapy irrespective of dose of cytarabine

    DEFF Research Database (Denmark)

    Johannsen, Katrine Helle; Handrup, Mette Møller; Lausen, Birgitte Frederiksen

    2013-01-01

    BACKGROUND: High-dose cytarabine has been associated with a high frequency of viridans group streptococcal (VGS) bacteraemia. VGS bacteraemia causes considerable morbidity and mortality. The Nordic Society of Paediatric Haematology and Oncology (NOPHO)-AML protocols use higher cumulated doses...... following courses with low-dose cytarabine versus courses with high-dose cytarabine. CONCLUSIONS: VGS were the most commonly isolated pathogens causing the most severe infections and the majority of life-threatening infections. A substantial proportion of the strains were resistant to penicillin. The high...... rate of VGS seemed independent of high-dose cytarabine but was more likely caused by the intensive chemotherapy treatment leading to severe mucositis and neutropenia....

  12. Irradiation dose and temperature dependence of fracture toughness in high dose HT9 steel from the fuel duct of FFTF

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Thak Sang, E-mail: byunts@ornl.gov [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Toloczko, Mychailo B. [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Saleh, Tarik A.; Maloy, Stuart A. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2013-01-15

    To expand the knowledge base for fast reactor core materials, fracture toughness has been evaluated for high dose HT9 steel using miniature disk compact tension (DCT) specimens. The HT9 steel DCT specimens were machined from the ACO-3 fuel duct of the Fast Flux Test Facility (FFTF), which achieved high doses in the range of 3-148 dpa at 378-504 Degree-Sign C. The static fracture resistance (J-R) tests have been performed in a servohydraulic testing machine in vacuum at selected temperatures including room temperature, 200 Degree-Sign C, and each irradiation temperature. Brittle fracture with a low toughness less than 50 MPa {radical}m occurred in room temperature tests when irradiation temperature was below 400 Degree-Sign C, while ductile fracture with stable crack growth was observed when irradiation temperature was higher. No fracture toughness less than 100 MPa {radical}m was measured when the irradiation temperature was above 430 Degree-Sign C. It was shown that the influence of irradiation temperature was dominant in fracture toughness while the irradiation dose has only limited influence over the wide dose range 3-148 dpa. A slow decrease of fracture toughness with test temperature above room temperature was observed for the nonirradiated and high temperature (>430 Degree-Sign C) irradiation cases, which indicates that the ductile-brittle transition temperatures (DBTTs) in those conditions are lower than room temperature. A comparison with the collection of existing data confirmed the dominance of irradiation temperature in the fracture toughness of HT9 steels.

  13. Definitive three-dimensional high-dose-rate brachytherapy for inoperable endometrial cancer

    Science.gov (United States)

    Draghini, Lorena; Casale, Michelina; Trippa, Fabio; Anselmo, Paola; Arcidiacono, Fabio; Fabiani, Stefania; Italiani, Marco; Chirico, Luigia; Muti, Marco

    2017-01-01

    Purpose To report our experience on high-dose-rate brachytherapy (HDR-BT) in patients with stage I-III endometrial cancer unfit to surgery. Material and methods Seventeen patients underwent HDR-BT as definitive treatment. Median age was 79 years (range, 60-95), median Karnofsky performance status 90% (range, 60-100). Histology was endometrial adenocarcinoma in 14 (82%), and non-endometrial in 3 (18%) patients. In 15 (88%) patients, clinical stage was I and in remaining 2 (12%) was III. All patients were evaluated with computed tomography (CT) and endometrial biopsy. Using the Fletcher applicator, a CT-based planning HDR-BT was delivered. Local control (LC) was obtained when there was an interruption of vaginal bleeding in absence of CT-imaging progression. Results Fourteen patients underwent HDR-BT alone and three external beam radiotherapy (EBRT) combined with HDR-BT. All patients had a clinical LC, after a median follow-up of 53 months (range, 6-131), 3 and 6 years LC rates were 86% and 69%, respectively. Cancer specific survival (CSS) at 1, 2, and 6 years was 93%, 85%, and 85%, respectively. Age, stage, dose, and type of radiotherapy did not result significant prognostic factors for LC and CSS. Only histology significantly influenced LC: for high-risk histology (i.e., non-endometrial carcinoma or grade [G] 3 endometrial adenocarcinoma) LC was 73% at 1 year and 36% at 6 years; for low-risk histology (i.e., G1-2 endometrial adenocarcinoma) was 100% at 1 and 6 years (p = 0.05). Two (12%) patients had G2 acute toxicity and two others (12%) G1 late toxicity. Conclusions Although some limitations of our analysis (relatively few number of patients recruited, retrospective evaluation, and consequent suboptimal patient selection), it confirms effectiveness and safety of definitive HDR-BT for medically inoperable stage I-III endometrial cancer. The best LC was obtained in stage I low-risk histology. PMID:28533799

  14. Definitive three-dimensional high-dose-rate brachytherapy for inoperable endometrial cancer

    Directory of Open Access Journals (Sweden)

    Lorena Draghini

    2017-04-01

    Full Text Available Purpose : To report our experience on high-dose-rate brachytherapy (HDR-BT in patients with stage I-III endometrial cancer unfit to surgery. Material and methods : Seventeen patients underwent HDR-BT as definitive treatment. Median age was 79 years (range, 60-95, median Karnofsky performance status 90% (range, 60-100. Histology was endometrial adenocarcinoma in 14 (82%, and non-endometrial in 3 (18% patients. In 15 (88% patients, clinical stage was I and in remaining 2 (12% was III. All patients were evaluated with computed tomography (CT and endometrial biopsy. Using the Fletcher applicator, a CT-based planning HDR-BT was delivered. Local control (LC was obtained when there was an interruption of vaginal bleeding in absence of CT-imaging progression. Results : Fourteen patients underwent HDR-BT alone and three external beam radiotherapy (EBRT combined with HDR-BT. All patients had a clinical LC, after a median follow-up of 53 months (range, 6-131, 3 and 6 years LC rates were 86% and 69%, respectively. Cancer specific survival (CSS at 1, 2, and 6 years was 93%, 85%, and 85%, respectively. Age, stage, dose, and type of radiotherapy did not result significant prognostic factors for LC and CSS. Only histology significantly influenced LC: for high-risk histology (i.e., non-endometrial carcinoma or grade [G] 3 endometrial adeno­carcinoma LC was 73% at 1 year and 36% at 6 years; for low-risk histology (i.e., G1-2 endometrial adenocarcinoma was 100% at 1 and 6 years (p = 0.05. Two (12% patients had G2 acute toxicity and two others (12% G1 late toxicity. Conclusions : Although some limitations of our analysis (relatively few number of patients recruited, retrospective evaluation, and consequent suboptimal patient selection, it confirms effectiveness and safety of definitive HDR-BT for medically inoperable stage I-III endometrial cancer. The best LC was obtained in stage I low-risk histology.

  15. Characterisation of high dose dry powder aerosols by cascade impaction and laser diffraction analysis

    NARCIS (Netherlands)

    Grasmeijer, F.; Hagedoorn, P.; Frijlink, H.W.; De Boer, A.H.

    2011-01-01

    Background: Developments in high dose dry powder inhalationcontinue to challenge the viability of pharmacopoeialmethods for drug aerosol characterisation. Especiallythe occurrence of bounce effects can cause the amount offines (<1 lm) to be highly overestimated in particle sizedistributions (PSDs) o

  16. The linear-quadratic model is inappropriate to model high dose per fraction effects in radiosurgery.

    Science.gov (United States)

    Kirkpatrick, John P; Meyer, Jeffrey J; Marks, Lawrence B

    2008-10-01

    The linear-quadratic (LQ) model is widely used to model the effect of total dose and dose per fraction in conventionally fractionated radiotherapy. Much of the data used to generate the model are obtained in vitro at doses well below those used in radiosurgery. Clinically, the LQ model often underestimates tumor control observed at radiosurgical doses. The underlying mechanisms implied by the LQ model do not reflect the vascular and stromal damage produced at the high doses per fraction encountered in radiosurgery and ignore the impact of radioresistant subpopulations of cells. The appropriate modeling of both tumor control and normal tissue toxicity in radiosurgery requires the application of emerging understanding of molecular-, cellular-, and tissue-level effects of high-dose/fraction-ionizing radiation and the role of cancer stem cells.

  17. Effects of high dose rate gamma radiation on survival and reproduction of Biomphalaria glabrata

    Energy Technology Data Exchange (ETDEWEB)

    Cantinha, Rebeca S.; Nakano, Eliana [Instituto Butantan, Sao Paulo, SP (Brazil). Lab. de Parasitologia], e-mail: rebecanuclear@gmail.com, e-mail: eliananakano@butantan.gov.br; Borrely, Sueli I. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes], e-mail: sborrely@ipen.br; Amaral, Ademir; Melo, Ana M.M.A. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Estudos em Radioprotecao e Radioecologia (GERAR)], e-mail: amaral@ufpe.br; Silva, Luanna R.S. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Biofisica e Radiobiologia. Lab. de Radiobiologia], e-mail: amdemelo@hotmail.com, e-mail: luannaribeiro_lua@hotmail.com

    2009-07-01

    Ionizing radiations are known as mutagenic agents, causing lethality and infertility. This characteristic has motivated its application on animal biological control. In this context, the freshwater snail Biomphalaria glabrata can be considered an excellent experimental model to study effects of ionizing radiations on lethality and reproduction. This work was designed to evaluate effects of {sup 60}Co gamma radiation at high dose rate (10.04 kGy/h) on B. glabrata. For this purpose, adult snails were selected and exposed to doses ranging from 20 to 100 Gy, with 10 Gy intervals; one group was kept as control. There was not effect of dose rate in the lethality of gamma radiation; the value of 64,3 Gy of LD{sub 50} obtained in our study was similar to that obtained by other authors with low dose rates. Nevertheless, our data suggest that there was a dose rate effect in the reproduction. On all dose levels, radiation improved the production of embryos for all exposed individuals. However, viability indexes were below 6% and, even 65 days after irradiation, fertility was not recovered. These results are not in agreement with other studies using low dose rates. Lethality was obtained in all groups irradiated, and the highest doses presented percentiles of dead animals above 50%. The results demonstrated that doses of 20 and 30 Gy were ideal for population control of B. glabrata. Further studies are needed; nevertheless, this research evidenced great potential of high dose rate gamma radiation on B. glabrata reproductive control. (author)

  18. SU-E-T-579: Impact of Cylinder Size in High-Dose Rate Brachytherapy (HDRBT) for Primary Cancer in the Vagina

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, H; Gopalakrishnan, M; Lee, P; Sathiaseelan, V [Department of Radiation Oncology, Northwestern Memorial Hospital, Chicago, IL (United States)

    2014-06-01

    Purpose: To evaluate the dosimetric impact of cylinder size in high dose rate Brachytherapy for primary vaginal cancers. Methods: Patients treated with HDR vaginal vault radiation in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm increment were analyzed. All patients’ doses were prescribed at the 0.5 cm from the vaginal surface with different treatment lengths. A series of reference points were created to optimize the dose distribution. The fraction dose was 5.5 Gy, the treatment was repeated for 4 times in two weeks. A cylinder volume was contoured in each case according to the prescribed treatment length, and then expanded to 5 mm to get a volume Cylinder-5mm-exp. A volume of PTV-Eval was obtained by subtracting the cylinder volume from the Cylinder-5mm-exp. The shell volume, PTV-Eval serves as the target volume for dosimetric evaluation. Results: DVH curves and average doses of PTV-Eval were obtained. Our results indicated that the DVH curves shifted toward higher dose side when larger cylinder was used instead of smaller ones. When 3.0 cm cylinder was used instead of 2.5 cm, for 3.0 cm treatment length, the average dose only increased 1%, from 790 to 799 cGy. However, the average doses for 3.5 and 4 cm cylinders respectively are 932 and 1137 cGy at the same treatment length. For 5.0 cm treatment length, the average dose is 741 cGy for 2.5 cm cylinder, and 859 cGy for 3 cm cylinder. Conclusion: Our data analysis suggests that for the vaginal intracavitary HDRBT, the average dose is at least 35% larger than the prescribed dose in the studied cases; the size of the cylinder will impact the dose delivered to the target volume. The cylinder with bigger diameter tends to deliver larger average dose to the PTV-Eval.

  19. A novel adaptive needle insertion sequencing for robotic, single needle MR-guided high-dose-rate prostate brachytherapy

    Science.gov (United States)

    Borot de Battisti, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; Maenhout, M.; Moerland, M. A.

    2017-05-01

    MR-guided high-dose-rate (HDR) brachytherapy has gained increasing interest as a treatment for patients with localized prostate cancer because of the superior value of MRI for tumor and surrounding tissues localization. To enable needle insertion into the prostate with the patient in the MR bore, a single needle MR-compatible robotic system involving needle-by-needle dose delivery has been developed at our institution. Throughout the intervention, dose delivery may be impaired by: (1) sub-optimal needle positioning caused by e.g. needle bending, (2) intra-operative internal organ motion such as prostate rotations or swelling, or intra-procedural rectum or bladder filling. This may result in failure to reach clinical constraints. To assess the first aforementioned challenge, a recent study from our research group demonstrated that the deposited dose may be greatly improved by real-time adaptive planning with feedback on the actual needle positioning. However, the needle insertion sequence is left to the doctor and therefore, this may result in sub-optimal dose delivery. In this manuscript, a new method is proposed to determine and update automatically the needle insertion sequence. This strategy is based on the determination of the most sensitive needle track. The sensitivity of a needle track is defined as its impact on the dose distribution in case of sub-optimal positioning. A stochastic criterion is thus presented to determine each needle track sensitivity based on needle insertion simulations. To assess the proposed sequencing strategy, HDR prostate brachytherapy was simulated on 11 patients with varying number of needle insertions. Sub-optimal needle positioning was simulated at each insertion (modeled by typical random angulation errors). In 91% of the scenarios, the dose distribution improved when the needle was inserted into the most compared to the least sensitive needle track. The computation time for sequencing was less than 6 s per needle track. The

  20. Infused vincristine and adriamycin with high dose methylprednisolone (VAMP) in advanced previously treated multiple myeloma patients.

    Science.gov (United States)

    Forgeson, G. V.; Selby, P.; Lakhani, S.; Zulian, G.; Viner, C.; Maitland, J.; McElwain, T. J.

    1988-01-01

    Forty-five patients with relapsed or refractory multiple myeloma received continuous infusions of vincristine (0.4 mg total dose daily for 4 days) and adriamycin (9 mg m-2 daily for 4 days) with a high dose of methylprednisolone (1 g m-2 i.v. or p.o. daily by 1 h infusion), the VAMP regimen. Sixteen (36%) responded, with a median duration of remission of 11 months and median survival of 20 months. Major toxicities encountered were infective and cardiovascular. Two smaller groups of myeloma patients were treated with high dose methylprednisolone (HDMP) alone, or VAMP plus weekly low dose cyclophosphamide (Cyclo-VAMP). HDMP produced short responses in 25% of patients with less toxicity than VAMP. Cyclo-VAMP was used in a highly selected group of patients who had previously responded to high dose melphalan. It was well tolerated and produced responses in 61% of this group. PMID:3207601

  1. Escalating dose pretreatment induces pharmacodynamic and not pharmacokinetic tolerance to a subsequent high-dose methamphetamine binge.

    Science.gov (United States)

    O'Neil, Meghan L; Kuczenski, Ronald; Segal, David S; Cho, Arthur K; Lacan, Goran; Melega, William P

    2006-11-01

    A major feature of human methamphetamine (METH) abuse is the gradual dose escalation that precedes high-dose exposure. The period of escalating doses (EDs) is likely associated with development of tolerance to aspects of METH's pharmacologic and toxic effects but the relative contributions of pharmacokinetic and pharmacodynamic factors have not been well defined. In our prior studies in rats, we showed that pretreatment with an ED-METH regimen (0.1-4.0 mg/kg over 14 days) attenuated the toxicity of a subsequently administered high-dose METH binge (4 x 6 mg/kg at 2 h interval) that itself produced behavioral stereotypy, increases in core temperature, and decreases in DA system phenotypic markers in caudate-putamen (CP). Using those ED-METH and binge protocols in the present studies, pharmacokinetic and pharmacodynamic parameters that may have contributed to the apparent neuroprotection afforded by ED-METH were assessed. The ED-METH regimen itself reduced [(3)H]WIN35,428 (WIN) binding to the dopamine transporter (DAT) by 15% in CP, but did not affect DA content. During the METH binge, ED-METH pretreated animals showed attenuated increases in core temperature while concurrent microdialysis studies in CP showed a reduced DA response despite unaltered extracellular levels of METH. At 1 h after the binge, concentrations of METH and its metabolite amphetamine in brain and plasma were unaffected by the ED-METH. The results show that ED-METH pretreatment produces reductions in DAT binding and the DA response during a subsequent METH binge by altering pharmacodynamic and not pharmacokinetic parameters.

  2. Absorbed dose-to-water protocol applied to synchrotron-generated x-rays at very high dose rates

    Science.gov (United States)

    Fournier, P.; Crosbie, J. C.; Cornelius, I.; Berkvens, P.; Donzelli, M.; Clavel, A. H.; Rosenfeld, A. B.; Petasecca, M.; Lerch, M. L. F.; Bräuer-Krisch, E.

    2016-07-01

    Microbeam radiation therapy (MRT) is a new radiation treatment modality in the pre-clinical stage of development at the ID17 Biomedical Beamline of the European synchrotron radiation facility (ESRF) in Grenoble, France. MRT exploits the dose volume effect that is made possible through the spatial fractionation of the high dose rate synchrotron-generated x-ray beam into an array of microbeams. As an important step towards the development of a dosimetry protocol for MRT, we have applied the International Atomic Energy Agency’s TRS 398 absorbed dose-to-water protocol to the synchrotron x-ray beam in the case of the broad beam irradiation geometry (i.e. prior to spatial fractionation into microbeams). The very high dose rates observed here mean the ion recombination correction factor, k s , is the most challenging to quantify of all the necessary corrections to apply for ionization chamber based absolute dosimetry. In the course of this study, we have developed a new method, the so called ‘current ramping’ method, to determine k s for the specific irradiation and filtering conditions typically utilized throughout the development of MRT. Using the new approach we deduced an ion recombination correction factor of 1.047 for the maximum ESRF storage ring current (200 mA) under typical beam spectral filtering conditions in MRT. MRT trials are currently underway with veterinary patients at the ESRF that require additional filtering, and we have estimated a correction factor of 1.025 for these filtration conditions for the same ESRF storage ring current. The protocol described herein provides reference dosimetry data for the associated Treatment Planning System utilized in the current veterinary trials and anticipated future human clinical trials.

  3. Acute high dose lithium-induced exacerbation of obsessive compulsive symptoms.

    Science.gov (United States)

    Umesh, Shreekantiah; Sinha, Vinod Kumar

    2014-05-01

    Obsessive compulsive disorder (OCD) is a chronic neuropsychiatric disorder whose pathophysiology is linked to serotonergic dysfunction. More recently, the role of glutamate has also been posited. Lithium is used as an adjunctive for the treatment of OCD which is found to enhance serotonergic transmission. We present a case of OCD who was on stable dose of sertraline developed exacerbation of obsessive compulsive symptoms with acute high dose of lithium but improved after dose reduction.

  4. On line high dose static position monitoring by ionization chamber detector for industrial gamma irradiators.

    Science.gov (United States)

    Rodrigues, Ary A; Vieira, Jose M; Hamada, Margarida M

    2010-01-01

    A 1 cm(3) cylindrical ionization chamber was developed to measure high doses on line during the sample irradiation in static position, in a (60)Co industrial plant. The developed ionization chamber showed to be suitable for use as a dosimeter on line. A good linearity of the detector was found between the dose and the accumulated charge, independently of the different dose rates caused by absorbing materials.

  5. A Grid Algorithm for High Throughput Fitting of Dose-Response Curve Data

    OpenAIRE

    Wang, Yuhong; Jadhav, Ajit; Southal, Noel; Huang, Ruili; Nguyen, Dac-Trung

    2010-01-01

    We describe a novel algorithm, Grid algorithm, and the corresponding computer program for high throughput fitting of dose-response curves that are described by the four-parameter symmetric logistic dose-response model. The Grid algorithm searches through all points in a grid of four dimensions (parameters) and finds the optimum one that corresponds to the best fit. Using simulated dose-response curves, we examined the Grid program’s performance in reproducing the actual values that were used ...

  6. On line high dose static position monitoring by ionization chamber detector for industrial gamma irradiators

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Ary A. [Universidade Estadual de Londrina-Depto de Fisica, Rodovia Celso Garcia Cid, km 38, 086051-990 Londrina (Brazil); Vieira, Jose M. [Instituto de Pesquisas Energeticas e Nucleares-IPEN/CNEN-SP, Prof. Lineu Prestes, 2242-Cidade Universitaria, 05508-900 Sao Paulo (Brazil); Hamada, Margarida M. [Instituto de Pesquisas Energeticas e Nucleares-IPEN/CNEN-SP, Prof. Lineu Prestes, 2242-Cidade Universitaria, 05508-900 Sao Paulo (Brazil)], E-mail: mmhamada@ipen.br

    2010-04-15

    A 1 cm{sup 3} cylindrical ionization chamber was developed to measure high doses on line during the sample irradiation in static position, in a {sup 60}Co industrial plant. The developed ionization chamber showed to be suitable for use as a dosimeter on line. A good linearity of the detector was found between the dose and the accumulated charge, independently of the different dose rates caused by absorbing materials.

  7. Dosimetric Evaluation of High-Dose-Rate Interstitial Brachytherapy Boost Treatments for Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Froehlich, Georgina [Semmelweis Univ., Budapest (Hungary); Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary); Agoston, Peter; Loevey, Jozsef; Somogyi, Andras; Fodor, Janos; Polgar, Csaba; Major, Tibor [Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary)

    2010-07-15

    Purpose: to quantitatively evaluate the dose distributions of high-dose-rate (HDR) prostate implants regarding target coverage, dose homogeneity, and dose to organs at risk. Material and methods: treatment plans of 174 implants were evaluated using cumulative dose-volume histograms (DVHs). The planning was based on transrectal ultrasound (US) imaging, and the prescribed dose (100%) was 10 Gy. The tolerance doses to rectum and urethra were 80% and 120%, respectively. Dose-volume parameters for target (V90, V100, V150, V200, D90, D{sub min}) and quality indices (DNR [dose nonuniformity ratio], DHI [dose homogeneity index], CI [coverage index], COIN [conformal index]) were calculated. Maximum dose in reference points of rectum (D{sub r}) and urethra (D{sub u}), dose to volume of 2 cm{sup 3} of the rectum (D{sub 2ccm}), and 0.1 cm{sup 3} and 1% of the urethra (D{sub 0.1ccm} and D1) were determined. Nonparametric correlation analysis was performed between these parameters. Results: the median number of needles was 16, the mean prostate volume (V{sub p}) was 27.1 cm{sup 3}. The mean V90, V100, V150, and V200 were 90%, 97%, 39% and 13%, respectively. The mean D90 was 109%, and the D{sub min} was 87%. The mean doses in rectum and urethra reference points were 75% and 119%, respectively. The mean volumetric doses were D{sub 2ccm} = 49% for the rectum, D{sub 0.1ccm} = 126%, and D1 = 140% for the urethra. The mean DNR was 0.37, while the DHI was 0.60. The mean COIN was 0.66. The Spearman rank order correlation coefficients for volume doses to rectum and urethra were R(D{sub r}, D{sub 2ccm}) = 0.69, R(D{sub u}, D{sub 0.1ccm}) = 0.64, R(D{sub u}, D1) = 0.23. Conclusion: US-based treatment plans for HDR prostate implants based on the real positions of catheters provided acceptable dose distributions. In the majority of the cases, the doses to urethra and rectum were kept below the defined tolerance levels. For rectum, the dose in reference points correlated well with dose

  8. High-precision radiosurgical dose delivery by interlaced microbeam arrays of high-flux low-energy synchrotron X-rays.

    Directory of Open Access Journals (Sweden)

    Raphaël Serduc

    Full Text Available Microbeam Radiation Therapy (MRT is a preclinical form of radiosurgery dedicated to brain tumor treatment. It uses micrometer-wide synchrotron-generated X-ray beams on the basis of spatial beam fractionation. Due to the radioresistance of normal brain vasculature to MRT, a continuous blood supply can be maintained which would in part explain the surprising tolerance of normal tissues to very high radiation doses (hundreds of Gy. Based on this well described normal tissue sparing effect of microplanar beams, we developed a new irradiation geometry which allows the delivery of a high uniform dose deposition at a given brain target whereas surrounding normal tissues are irradiated by well tolerated parallel microbeams only. Normal rat brains were exposed to 4 focally interlaced arrays of 10 microplanar beams (52 microm wide, spaced 200 microm on-center, 50 to 350 keV in energy range, targeted from 4 different ports, with a peak entrance dose of 200Gy each, to deliver an homogenous dose to a target volume of 7 mm(3 in the caudate nucleus. Magnetic resonance imaging follow-up of rats showed a highly localized increase in blood vessel permeability, starting 1 week after irradiation. Contrast agent diffusion was confined to the target volume and was still observed 1 month after irradiation, along with histopathological changes, including damaged blood vessels. No changes in vessel permeability were detected in the normal brain tissue surrounding the target. The interlacing radiation-induced reduction of spontaneous seizures of epileptic rats illustrated the potential pre-clinical applications of this new irradiation geometry. Finally, Monte Carlo simulations performed on a human-sized head phantom suggested that synchrotron photons can be used for human radiosurgical applications. Our data show that interlaced microbeam irradiation allows a high homogeneous dose deposition in a brain target and leads to a confined tissue necrosis while sparing

  9. Determinants of Quality of Life in High-Dose Benzodiazepine Misusers

    Directory of Open Access Journals (Sweden)

    Stefano Tamburin

    2017-01-01

    Full Text Available Benzodiazepines (BZDs are among the most widely prescribed drugs in developed countries, but they have a high potential for tolerance, dependence and misuse. High-dose BZD misuse represents an emerging addiction phenomenon, but data on quality of life (QoL in high-dose BZD misusers are scant. This study aimed to explore QoL in high-dose BZD misuse. We recruited 267 high-dose BZD misusers, compared the QoL scores in those who took BZD only to poly-drug misusers, and explored the role of demographic and clinical covariates through multivariable analysis. Our data confirmed worse QoL in high-dose BZD misusers and showed that (a QoL scores were not negatively influenced by the misuse of alcohol or other drugs, or by coexisting psychiatric disorders; (b demographic variables turned out to be the most significant predictors of QoL scores; (c BZD intake significantly and negatively influenced QoL. Physical and psychological dimensions of QoL are significantly lower in high-dose BZD misusers with no significant effect of comorbidities. Our data suggest that the main reason for poor QoL in these patients is high-dose BZD intake per se. QoL should be considered among outcome measures in these patients.

  10. Determinants of Quality of Life in High-Dose Benzodiazepine Misusers

    Science.gov (United States)

    Tamburin, Stefano; Federico, Angela; Faccini, Marco; Casari, Rebecca; Morbioli, Laura; Sartore, Valentina; Mirijello, Antonio; Addolorato, Giovanni; Lugoboni, Fabio

    2017-01-01

    Benzodiazepines (BZDs) are among the most widely prescribed drugs in developed countries, but they have a high potential for tolerance, dependence and misuse. High-dose BZD misuse represents an emerging addiction phenomenon, but data on quality of life (QoL) in high-dose BZD misusers are scant. This study aimed to explore QoL in high-dose BZD misuse. We recruited 267 high-dose BZD misusers, compared the QoL scores in those who took BZD only to poly-drug misusers, and explored the role of demographic and clinical covariates through multivariable analysis. Our data confirmed worse QoL in high-dose BZD misusers and showed that (a) QoL scores were not negatively influenced by the misuse of alcohol or other drugs, or by coexisting psychiatric disorders; (b) demographic variables turned out to be the most significant predictors of QoL scores; (c) BZD intake significantly and negatively influenced QoL. Physical and psychological dimensions of QoL are significantly lower in high-dose BZD misusers with no significant effect of comorbidities. Our data suggest that the main reason for poor QoL in these patients is high-dose BZD intake per se. QoL should be considered among outcome measures in these patients.

  11. Gafchromic EBT-XD film: Dosimetry characterization in high-dose, volumetric-modulated arc therapy.

    Science.gov (United States)

    Miura, Hideharu; Ozawa, Shuichi; Hosono, Fumika; Sumida, Naoki; Okazue, Toshiya; Yamada, Kiyoshi; Nagata, Yasushi

    2016-11-08

    Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT-XD films have been designed for optimal performance in the 40-4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose-response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high-dose volumetric-modulated arc therapy (VMAT) verification. A 10 MV beam from a TrueBeam STx linear accelerator was used to irradiate the films with doses in the 0-4,000 cGy range. Postexposure coloration was analyzed at postirradiation times ranging from several minutes to 48 h. The films were also irradiated with 6 MV (dose rate (DR): 600 MU/min), 6 MV flattening filter-free (FFF) (DR: 1,400 MU/ min), and 10 MV FFF (DR: 2,400 MU/min) beams to determine the energy and dose-rate dependence. For clinical examinations, we compared the dose distribu-tion measured with EBT-XD films and calculated by the planning system for four VMAT cases. The red channel of the EBT-XD film exhibited a wider dynamic range than the green and blue channels. Scanner orientation yielded a variation of ~ 3% in the net optical density (OD). The difference between the film front and back scan orientations was negligible, with variation of ~ 1.3% in the net OD. The net OD increased sharply within the first 6 hrs after irradiation and gradually afterwards. No significant difference was observed for the beam energy and dose rate, with a variation of ~ 1.5% in the net OD. The gamma passing rates (at 3%, 3 mm) between the film- measured and treatment planning system (TPS)-calculated dose distributions under a high dose VMAT plan in the absolute dose mode were more than 98.9%. © 2016 The Authors.

  12. High-dose gadolinium-enhanced MRI for diagnosis of meningeal metastases

    Energy Technology Data Exchange (ETDEWEB)

    Kallmes, D.F. [Department of Radiology, Box 170, University of Virginia Health Sciences Center, Charlottesville, VA 22908 (United States); Gray, L. [Department of Radiology, Duke University Medical Center, Durham, NC (United States); Glass, J.P. [Department of Medicine, Veterans Administration Hospital, Gainesville, Florida (United States)

    1998-01-01

    We compared high-dose (0.3 mmol/kg) and standard-dose (0.1 mmol/kg) gadolinium-enhanced MRI for diagnosis of meningeal metastases in 12 patients with suspected meningeal metastases. They were imaged with both standard-dose and high-dose gadolinium. All patients with abnormal meningeal enhancement underwent at least one lumbar puncture for cerebrospinal fluid (CSF) cytology, while patients with normal meningeal enhancement were followed clinically. All patients with negative CSF cytology also were followed clinically. A single observer reviewed all the images, with specific attention to the enhancement pattern of the meninges. Abnormal leptomeningeal enhancement was present in three cases, and abnormal pachymeningeal enhancement in three other patients. All of these patients had abnormal CSF analyses. In two of the three cases of abnormal leptomeningeal enhancement the disease was more evident on high-dose than on standard-dose imaging; in one case the abnormal enhancement was visible only on high-dose imaging. In one of the three cases with abnormal pachymeningeal enhancement, the disease was evident prospectively only with high-dose imaging. (orig.) With 3 figs., 10 refs.

  13. A comparative analysis of radiobiological models for cell surviving fractions at high doses.

    Science.gov (United States)

    Andisheh, B; Edgren, M; Belkić, Dž; Mavroidis, P; Brahme, A; Lind, B K

    2013-04-01

    For many years the linear-quadratic (LQ) model has been widely used to describe the effects of total dose and dose per fraction at low-to-intermediate doses in conventional fractionated radiotherapy. Recent advances in stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) have increased the interest in finding a reliable cell survival model, which will be accurate at high doses, as well. Different models have been proposed for improving descriptions of high dose survival responses, such as the Universal Survival Curve (USC), the Kavanagh-Newman (KN) and several generalizations of the LQ model, e.g. the Linear-Quadratic-Linear (LQL) model and the Pade Linear Quadratic (PLQ) model. The purpose of the present study is to compare a number of models in order to find the best option(s) which could successfully be used as a fractionation correction method in SRT. In this work, six independent experimental data sets were used: CHOAA8 (Chinese hamster fibroblast), H460 (non-small cell lung cancer, NSLC), NCI-H841 (small cell lung cancer, SCLC), CP3 and DU145 (human prostate carcinoma cell lines) and U1690 (SCLC). By detailed comparisons with these measurements, the performance of nine different radiobiological models was examined for the entire dose range, including high doses beyond the shoulder of the survival curves. Using the computed and measured cell surviving fractions, comparison of the goodness-of-fit for all the models was performed by means of the reduced χ (2)-test with a 95% confidence interval. The obtained results indicate that models with dose-independent final slopes and extrapolation numbers generally represent better choices for SRT. This is especially important at high doses where the final slope and extrapolation numbers are presently found to play a major role. The PLQ, USC and LQL models have the least number of shortcomings at all doses. The extrapolation numbers and final slopes of these models do not depend on dose. Their asymptotes

  14. Concomitant cervical and transperineal parametrial high-dose-rate brachytherapy boost for locally advanced cervical cancer

    Directory of Open Access Journals (Sweden)

    Caroline Bailleux

    2016-01-01

    Full Text Available Purpose: There is no consensus for parametrial boost technic while both transvaginal and transperineal approaches are discussed. A prototype was developed consisting of a perineal template, allowing transperineal needle insertion. This study analyzed acute toxicity of concomitant cervical and transperineal parametrial high-dose-rate brachytherapy (HDRB boost for locally advanced cervical cancer. Material and methods: From 01.2011 to 12.2014, 33 patients (pts presenting a locally advanced cervical cancer with parametrial invasion were treated. After the first course of external beam radiation therapy with cisplatinum, HDRB was performed combining endocavitary and interstitial technique for cervical and parametrial disease. Post-operative delineation (CTV, bladder, rectum, sigmoid and planification were based on CT-scan/MRI. HDRB was delivered in 3-5 fractions over 2-3 consecutive days. Acute toxicities occurring within 6 months after HDRB were retrospectively reviewed. Results: Median age was 56.4 years (27-79. Clinical stages were: T2b = 23 pts (69.7%, T3a = 1 pt (3%, T3b = 6 pts (18.2%, and T4a = 3 pts (9.1%. Median HDRB prescribed dose was 21 Gy (21-27. Median CTVCT (16 pts and HR-CTV MRI (17 pts were 52.6 cc (28.5-74.3, 31.9 cc (17.1-58, respectively. Median EQD2αβ10 for D90CTV and D90HR-CTV were 82.9 Gy (78.2-96.5, 84.8 Gy (80.6-91.4, respectively. Median EQD2αβ3 (CT/MRI for D2cc bladder, rectum and sigmoid were 75.5 Gy (66.6-90.9, 64.4 Gy (51.9-77.4, and 60.4 Gy (50.9-81.1, respectively. Median follow-up was 14 months (ranged 6-51. Among the 24 pts with MFU = 24 months, 2-year LRFS rate, RRFS, and OS were 86.8%, 88.8%, and 94.1%, respectively. The rates of acute genitourinary and gastrointestinal toxicities were 36% (G1 dysuria = 8 pts, G2 infection = 2 pt, G3 infection = 2 pts, and 27% (G1 diarrhea = 9 pts, respectively. One patient presented vaginal bleeding at the time of applicator withdrawal (G3-blood transfusion; no bleeding was

  15. Study of the Melting Latent Heat of Semicrystalline PVDF applied to High Gamma Dose Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Batista, Adriana S.M. [Departamento de Anatomia e Imagem - IMA, Universidade Federal de Minas Gerais, Av. Prof. Alfredo Balena, 190, 30130-100, Belo Horizonte, MG (Brazil); Gual, Maritza R.; Faria, Luiz O. [Centro de Desenvolvimento da Tecnologia Nuclear - CDTN, Av. Antonio Carlos 6627, C.P. 941, 31270-901, Belo Horizonte, MG (Brazil); Lima, Claubia P.B. [Departamento de Engenharia Nuclear - DEN, Universidade Federal de Minas Gerais - UFMG, Av. Antonio Carlos 6627, 31270-970 Belo Horizonte, MG (Brazil)

    2015-07-01

    Poly(vinylidene fluoride) homopolymers [PVDF] homopolymers were irradiated with gamma doses ranging from 0.5 to 2.75 MGy. Differential scanning calorimetry (DSC) and FTIR spectrometry were used in order to study the effects of gamma radiation in the amorphous and crystalline polymer structures. The FTIR data revealed absorption bands at 1730 and 1853 cm{sup -1} which were attributed to the stretch of C=O bonds, at 1715 and 1754 cm{sup -1} which were attributed to the C=C stretching and at 3518, 3585 and 3673 cm{sup -1} which were associated with NH stretch of NH{sub 2} and OH. The melting latent heat (LM) measured by DSC was used to construct an unambiguous relationship with the delivered dose. Regression analyses revealed that the best mathematical function that fits the experimental calibration curve is a 4-degree polynomial function, with an adjusted Rsquare of 0.99817. (authors)

  16. Efficacy and tolerability of high-dose phenobarbital in children with focal seizures.

    Science.gov (United States)

    Okumura, Akihisa; Nakahara, Eri; Ikeno, Mitsuru; Abe, Shinpei; Igarashi, Ayuko; Nakazawa, Mika; Takasu, Michihiko; Shimizu, Toshiaki

    2016-04-01

    We retrospectively reviewed the outcomes of children with focal epilepsy treated with oral high-dose phenobarbital. We reviewed data on children (agedphenobarbital (>5 mg/kg/day to maintain a target serum level >40 μg/mL) for at least 6 months. Seizure frequency was evaluated after phenobarbital titration, and 1 and 2 years after high-dose phenobarbital treatment commenced. Treatment was judged effective when seizure frequencies fell by ⩾75%. Seven boys and eight girls were treated. The median age at commencement of high-dose phenobarbital therapy was 30 months. The maximal serum phenobarbital level ranged from 36.5 to 62.9 μg/mL. High-dose PB was effective in seven. In two patients, treatment was transiently effective, but seizure frequency later returned to the baseline. High-dose PB was ineffective in six. No significant association between effectiveness and any clinical variable was evident. Drowsiness was recorded in nine patients, but no patient developed a behavioral problem or hypersensitivity. Oral high-dose phenobarbital was effective in 7 of 15 patients with focal epilepsy and well tolerated. High-dose PB may be useful when surgical treatment is difficult. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  17. A new model of biodosimetry to integrate low and high doses.

    Directory of Open Access Journals (Sweden)

    Mònica Pujol

    Full Text Available Biological dosimetry, that is the estimation of the dose of an exposure to ionizing radiation by a biological parameter, is a very important tool in cases of radiation accidents. The score of dicentric chromosomes, considered to be the most accurate method for biological dosimetry, for low LET radiation and up to 5 Gy, fits very well to a linear-quadratic model of dose-effect curve assuming the Poisson distribution. The accuracy of this estimation raises difficulties for doses over 5 Gy, the highest dose of the majority of dose-effect curves used in biological dosimetry. At doses over 5 Gy most cells show difficulties in reaching mitosis and cannot be used to score dicentric chromosomes. In the present study with the treatment of lymphocyte cultures with caffeine and the standardization of the culture time, metaphases for doses up to 25 Gy have been analyzed. Here we present a new model for biological dosimetry, which includes a Gompertz-type function as the dose response, and also takes into account the underdispersion of aberration-among-cell distribution. The new model allows the estimation of doses of exposures to ionizing radiation of up to 25 Gy. Moreover, the model is more effective in estimating whole and partial body exposures than the classical method based on linear and linear-quadratic functions, suggesting their effectiveness and great potential to be used after high dose exposures of radiation.

  18. A New Model of Biodosimetry to Integrate Low and High Doses

    Science.gov (United States)

    Pujol, Mònica; Barquinero, Joan-Francesc; Puig, Pedro; Puig, Roser; Caballín, María Rosa; Barrios, Leonardo

    2014-01-01

    Biological dosimetry, that is the estimation of the dose of an exposure to ionizing radiation by a biological parameter, is a very important tool in cases of radiation accidents. The score of dicentric chromosomes, considered to be the most accurate method for biological dosimetry, for low LET radiation and up to 5 Gy, fits very well to a linear-quadratic model of dose-effect curve assuming the Poisson distribution. The accuracy of this estimation raises difficulties for doses over 5 Gy, the highest dose of the majority of dose-effect curves used in biological dosimetry. At doses over 5 Gy most cells show difficulties in reaching mitosis and cannot be used to score dicentric chromosomes. In the present study with the treatment of lymphocyte cultures with caffeine and the standardization of the culture time, metaphases for doses up to 25 Gy have been analyzed. Here we present a new model for biological dosimetry, which includes a Gompertz-type function as the dose response, and also takes into account the underdispersion of aberration-among-cell distribution. The new model allows the estimation of doses of exposures to ionizing radiation of up to 25 Gy. Moreover, the model is more effective in estimating whole and partial body exposures than the classical method based on linear and linear-quadratic functions, suggesting their effectiveness and great potential to be used after high dose exposures of radiation. PMID:25461738

  19. Assessment of targeted and non-targeted responses in cells deficient in ATM function following exposure to low and high dose X-rays.

    Science.gov (United States)

    Kiuru, Anne; Kämäräinen, Meerit; Heinävaara, Sirpa; Pylkäs, Katri; Chapman, Kim; Koivistoinen, Armi; Parviainen, Teuvo; Winqvist, Robert; Kadhim, Munira; Launonen, Virpi; Lindholm, Carita

    2014-01-01

    Radiation sensitivity at low and high dose exposure to X-rays was investigated by means of chromosomal aberration (CA) analysis in heterozygous ATM mutation carrier and A-T patient (biallelic ATM mutation) lymphoblastoid cell lines (LCLs). Targeted and non-targeted responses to acutely delivered irradiation were examined by applying a co-culture system that enables study of both directly irradiated cells and medium-mediated bystander effects in the same experimental setting. No indication of radiation hypersensitivity was observed at doses of 0.01 Gy or 0.1 Gy for the ATM mutation carrier LCL. The A-T patient cells also did not show low-dose response. There was significant increase in unstable CA yields for both ATM mutation carrier and A-T LCLs at 1 and 2 Gy, the A-T cells displaying more distinct dose dependency. Both chromosome and chromatid type aberrations were induced at an increased rate in the irradiated A-T cells, whereas for ATM carrier cells, only unstable chromosomal aberrations were increased above the level observed in the wild type cell line. No bystander effect could be demonstrated in any of the cell lines or doses applied. Characteristics typical for the A-T cell line were detected, i.e., high baseline frequency of CA that increased with dose. In addition, dose-dependent loss of cell viability was observed. In conclusion, CA analysis did not demonstrate low-dose (≤100 mGy) radiosensitivity in ATM mutation carrier cells or A-T patient cells. However, both cell lines showed increased radiosensitivity at high dose exposure.

  20. Assessment of targeted and non-targeted responses in cells deficient in ATM function following exposure to low and high dose X-rays.

    Directory of Open Access Journals (Sweden)

    Anne Kiuru

    Full Text Available Radiation sensitivity at low and high dose exposure to X-rays was investigated by means of chromosomal aberration (CA analysis in heterozygous ATM mutation carrier and A-T patient (biallelic ATM mutation lymphoblastoid cell lines (LCLs. Targeted and non-targeted responses to acutely delivered irradiation were examined by applying a co-culture system that enables study of both directly irradiated cells and medium-mediated bystander effects in the same experimental setting. No indication of radiation hypersensitivity was observed at doses of 0.01 Gy or 0.1 Gy for the ATM mutation carrier LCL. The A-T patient cells also did not show low-dose response. There was significant increase in unstable CA yields for both ATM mutation carrier and A-T LCLs at 1 and 2 Gy, the A-T cells displaying more distinct dose dependency. Both chromosome and chromatid type aberrations were induced at an increased rate in the irradiated A-T cells, whereas for ATM carrier cells, only unstable chromosomal aberrations were increased above the level observed in the wild type cell line. No bystander effect could be demonstrated in any of the cell lines or doses applied. Characteristics typical for the A-T cell line were detected, i.e., high baseline frequency of CA that increased with dose. In addition, dose-dependent loss of cell viability was observed. In conclusion, CA analysis did not demonstrate low-dose (≤100 mGy radiosensitivity in ATM mutation carrier cells or A-T patient cells. However, both cell lines showed increased radiosensitivity at high dose exposure.

  1. Variation in long-term antipsychotic polypharmacy and high-dose prescribing across physicians and hospitals.

    Science.gov (United States)

    Latimer, Eric A; Naidu, Adonia; Moodie, Erica E M; Clark, Robin E; Malla, Ashok K; Tamblyn, Robyn; Wynant, Willy

    2014-10-01

    This study had two aims: to measure the prevalence of long-term prescribing of high doses of antipsychotics and antipsychotic polypharmacy in a large Canadian province and to estimate the relative contributions of patient-, physician-, and hospital-level factors. Government hospital discharge, physician, and pharmaceutical claims data were linked to identify individuals with schizophrenia who in 2004 had antipsychotics available to them for at least 11 months. Individuals on a high dose throughout that period, as well as individuals on multiple concurrent antipsychotics (polypharmacy), were identified. Logistic and generalized linear mixed models using patient-, physician-, and hospital-level predictors were estimated. Among the 12,150 individuals identified, 11.9% were on a high dose and 10.4% on antipsychotic polypharmacy continually, with 3.7% in both groups. After adjustment for potential confounders, analyses showed that systematic propensity for physicians to prescribe high doses accounted for 10.9% of the remaining unexplained variance, and physicians as a group who prescribed high doses across a hospital or psychiatry department accounted for 3.0%. For antipsychotic polypharmacy the corresponding percentages were 9.7% and 6.2%. Even after adjustment, the variation in high-dose prescribing and antipsychotic polypharmacy remained substantial. Long-term high-dose and antipsychotic polypharmacy prescribing appeared partly driven by some physicians' and some hospitals' propensities to prescribe in this way independently of patient characteristics. Given the weight of the evidence against high-dose prescribing and antipsychotic polypharmacy, measures addressed to physicians and hospitals most likely to prescribe high doses, antipsychotic polypharmacy, or both should be considered.

  2. Maternal high-dose folic acid during pregnancy and asthma medication in the offspring

    NARCIS (Netherlands)

    Zetstra-van der Woude, Priscilla A.; De Walle, Hermien E. K.; Hoek, Annemieke; Bos, H. Jens; Boezen, H. Marike; Koppelman, Gerhard H.; de Jong-van den Berg, Lolkje T. W.; Scholtens, Salome

    2014-01-01

    Purpose Low-dose folic acid supplementation (0.5 mg) taken during pregnancy has been associated with an increased risk for childhood asthma. The effect of high-dose folic acid (5 mg) advised to women at risk for having a child with neural tube defect has not been assessed so far. Our aim was to inve

  3. Extra-high doses detected in the enamel of human teeth in the Techa riverside region

    Energy Technology Data Exchange (ETDEWEB)

    Shishkina, E.A., E-mail: ElenaA.Shishkina@gmail.com [Urals Research Center for Radiation Medicine, 68A, Vorovsky Str., 454076 Chelyabinsk (Russian Federation); Degteva, M.O.; Tolstykh, E.I.; Volchkova, A. [Urals Research Center for Radiation Medicine, 68A, Vorovsky Str., 454076 Chelyabinsk (Russian Federation); Ivanov, D.V. [Institute of Metal Physics, Russian Academy of Sciences, 18 S. Kovalevsky Str, 620041 Yekaterinburg (Russian Federation); Wieser, A. [Helmholtz Zentrum Muenchen, German Research Centre for Environmental Health, D-85764 Neuherberg (Germany); Della Monaca, S. [Istituto Superiore di Sanita, 00161 Rome (Italy); Istituto Regina Elena, 00144 Rome (Italy); Fattibene, P. [Istituto Superiore di Sanita, 00161 Rome (Italy); Istituto Nazionale di Fisica Nucleare, 00161 Rome (Italy)

    2011-09-15

    During the long-term study of tooth enamel by EPR dosimetry for population exposed to radiation due to contamination of the Techa River, it was found out that for some of the tooth donors the dose accumulated in tooth enamel could be as high as several tens of Gy. Such doses were absorbed only in tooth enamel and they should not be associated with exposures to other organs or the whole body. The nature of such doses was discussed in a number of previous papers where it was shown that the source of such doses is {sup 90}Sr incorporated in the calcified dental tissues. However, among specialists in radiation dosimetry who were not involved in the biokinetic studies, the nature and dosimetric significance of extra-high doses in tooth enamel are still raising questions. The aim of the current paper is to summarize the accumulated information on extra-high doses in the teeth of the Techa riverside residents, describe the dose levels observed, explain the nature of extra-high doses in the enamel and discuss their informative value. The paper includes an overview of already published findings and an analysis of information collected in the data bank of the Urals Research Center for Radiation Medicine (URCRM), Chelyabinsk, Russia, which has not been published before.

  4. Targeting MRS-Defined Dominant Intraprostatic Lesions with Inverse-Planned High Dose Rate Brachytherapy. Addendum

    Science.gov (United States)

    2009-06-01

    compromising the dose coverage of the prostate and the protection to the urethra , rectum, and bladder for prostate cancer patients treated with High...fusion, dose escalation, prostate cancer 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME OF...18 4 INTRODUCTION Research Project Description Men with prostate cancer , in particular those with advanced

  5. Comparative Effectiveness of High-Dose Versus Standard-Dose Influenza Vaccines Among US Medicare Beneficiaries in Preventing Postinfluenza Deaths During 2012-2013 and 2013-2014.

    Science.gov (United States)

    Shay, David K; Chillarige, Yoganand; Kelman, Jeffrey; Forshee, Richard A; Foppa, Ivo M; Wernecke, Michael; Lu, Yun; Ferdinands, Jill M; Iyengar, Arjun; Fry, Alicia M; Worrall, Chris; Izurieta, Hector S

    2017-02-15

    Recipients of high-dose vs standard-dose influenza vaccines have fewer influenza illnesses. We evaluated the comparative effectiveness of high-dose vaccine in preventing postinfluenza deaths during 2012-2013 and 2013-2014, when influenza viruses and vaccines were similar. We identified Medicare beneficiaries aged ≥65 years who received high-dose or standard-dose vaccines in community-located pharmacies offering both vaccines. The primary outcome was death in the 30 days following an inpatient or emergency department encounter listing an influenza International of Classification of Diseases, Ninth Revision, Clinical Modification code. Effectiveness was estimated by using multivariate Poisson regression models; effectiveness was allowed to vary by season. We studied 1039645 recipients of high-dose and 1683264 recipients of standard-dose vaccines during 2012-2013, and 1508176 high-dose and 1877327 standard-dose recipients during 2013-2014. Vaccinees were well-balanced for medical conditions and indicators of frail health. Rates of postinfluenza death were 0.028 and 0.038/10000 person-weeks in high-dose and standard-dose recipients, respectively. Comparative effectiveness was 24.0% (95% confidence interval [CI], .6%-42%); there was evidence of variation by season (P = .12). In 2012-2013, high-dose was 36.4% (95% CI, 9.0%-56%) more effective in reducing mortality; in 2013-2014, it was 2.5% (95% CI, -47% to 35%). High-dose vaccine was significantly more effective in preventing postinfluenza deaths in 2012-2013, when A(H3N2) circulation was common, but not in 2013-2014.

  6. Chronic low-dose radiation protects cells from high-dose radiation via increase of AKT expression by NF-{sub k}B

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyung Sun; Seong, Ki Moon; Kim, Ji Young; Kim, Cha Soon; Yang, Kwang Hee; Nam, Seon Young [Radiation Effect Research Team, Radiation Health Research Institute, Korea Hydro and Nuclear Power Co., LTD., Gyeongju (Korea, Republic of)

    2013-04-15

    Exposure to low-dose and low-dose rate of ionizing radiation is an important issue in radiation protection. Low-dose ionizing radiation has been observed to elicit distinctly different responses compared to high-dose radiation, in various biological systems including the reproductive, immune, and hematopoietic systems (Liu et al. 2006). Some data were reported that low-dose radiation could initiate beneficial effects by stimulating cell growth, DNA repair, activation of transcription factors and gene expression (Calabrese et al., 2004). Cells exposed to low-dose radiation can develop adaptive resistance to subsequent high-dose radiation induced DNA damage, gene mutation, and cell death. We previously reported that low-dose of ionizing radiation induced cell survival through the activation of AKT (protein kinase B, PKB) pathway (Park et al., 2009). AKT has been shown to be potently activated in response to a wide variety of growth factors and ionizing radiation. Cell survival against ionizing radiation seems to be associated with the activation of AKT pathway via phosphorylation of its downstream nuclear target molecules. In the present study, we examined the effects of chronic low-dose irradiation in human lung fibroblast cells. The aim was to explore the possibility of a low-dose radiation-induced adaptive cellular response against subsequent challenging high-dose irradiation. In the present study, we examined the regulatory mechanism responsible for cellular response induced by chronic low-dose of ionizing radiation in normal human cells. We found that the level of AKT protein was closely associated with cell survival. In addition, NF-{sub k}B activation by chronic low-dose radiation regulates AKT activation via gene expression and acinus expression. In conclusion, our data demonstrate that chronic low-dose radiation could inhibit the cell death induced by cytotoxic high-dose radiation through the modulation of the level of AKT and acinus proteins via NF-{sub k

  7. Prospective study of long-term impact of adjuvant high-dose and conventional-dose chemotherapy on health-related quality of life

    NARCIS (Netherlands)

    Buijs, C.; Rodenhuis, S.; Seynaeve, C.M.; van Hoesel, Q.G.; van der Wall, E.; Smit, W.J.; Nooij, M.A.; Voest, E.; Hupperets, P.; TenVergert, E.M.; van Tinteren, H.; Willemse, P.H.; Mourits, M.J.; Aaronson, N.K.; Post, W.J.; de Vries, E.G.

    2007-01-01

    Purpose To evaluate and compare health-related quality of life (HRQOL) after conventional- and high-dose adjuvant chemotherapy in patients with high-risk breast cancer. Patients and Methods Patients were randomly assigned to either a conventional or high-dose chemotherapy regimen; both regimens were

  8. A centre-triggered magnesium fuelled cathodic arc thruster uses sublimation to deliver a record high specific impulse

    Science.gov (United States)

    Neumann, Patrick R. C.; Bilek, Marcela; McKenzie, David R.

    2016-08-01

    The cathodic arc is a high current, low voltage discharge that operates in vacuum and provides a stream of highly ionised plasma from a solid conducting cathode. The high ion velocities, together with the high ionisation fraction and the quasineutrality of the exhaust stream, make the cathodic arc an attractive plasma source for spacecraft propulsion applications. The specific impulse of the cathodic arc thruster is substantially increased when the emission of neutral species is reduced. Here, we demonstrate a reduction of neutral emission by exploiting sublimation in cathode spots and enhanced ionisation of the plasma in short, high-current pulses. This, combined with the enhanced directionality due to the efficient erosion profiles created by centre-triggering, substantially increases the specific impulse. We present experimentally measured specific impulses and jet power efficiencies for titanium and magnesium fuels. Our Mg fuelled source provides the highest reported specific impulse for a gridless ion thruster and is competitive with all flight rated ion thrusters. We present a model based on cathode sublimation and melting at the cathodic arc spot explaining the outstanding performance of the Mg fuelled source. A further significant advantage of an Mg-fuelled thruster is the abundance of Mg in asteroidal material and in space junk, providing an opportunity for utilising these resources in space.

  9. An ultra-high dose of electron radiation response of Germanium Flat Fiber and TLD-100

    Science.gov (United States)

    Alawiah, A.; Amin, Y. M.; Abdul-Rashid, H. A.; Abdullah, W. S. Wan; Maah, M. J.; Bradley, D. A.

    2017-01-01

    The thermoluminescence (TL) response of Germanium Flat Fiber (GFF) and TLD-100 irradiated with 2.5 MeV electrons for the doses up to 1 MGy were studied and compared. The aim was to evaluate the TL supralinearity response at an ultra-high dose (UHD) range and to investigate the change in kinetic parameters of the glow peaks, as the doses increases up to 1 MGy. It is found that the critical dose limit (CDL) of GFF is 5 times higher as compared to TLD-100. CDL is determined by the dose at the maximum supralinearity, f(D)max. It is also found that annealing the TLD-100 and GFF with temperature more than 400 °C is required to reset it back to its original condition, following radiation doses up to 1 MGy. It is also noticed the strange behavior of Peak 4 (TLD-100), which tends to be invisible at the lower dose (<10 kGy) and starts to be appeared at the critical dose limit of 10 kGy. This result might be an important clue to understand the behavior of TLD-100 at extremely high dose range. For both samples, it is observed that the TL intensity is not saturated within the UHD range studied.

  10. A case of percutaneous high dose rate brachytherapy for superior pulmonary sulcus tumor

    Energy Technology Data Exchange (ETDEWEB)

    Asakura, Tamaki; Imamura, Masahiro; Murata, Takashi [Kansai Medical Univ., Moriguchi, Osaka (Japan)] [and others

    1996-07-01

    A 64-year-old man with advanced superior pulmonary sulcus tumor suffered severe unrelieved pain even after chemotherapy, external irradiation and hyperthermia. So we planned to introduce a percutaneous high dose rate brachytherapy using the microselectron HDR {sup 192}Ir. With the estimation using the Pain Score, satisfying pain relief was attainable with a combination of the percutaneous high dose rate brachytherapy and conventional treatment. So the percutaneous high dose rate brachytherapy had the possibility to contribute to the alleviation of the pain. (author)

  11. "Half-half" blisters in bullous pemphigoid successfully treated with adjuvant high-dose intravenous immunoglobulin.

    Science.gov (United States)

    Pacheco, David; Lopes, Leonor; Soares-Almeida, Luis; Marques, Manuel Sacramento; Filipe, Paulo

    2012-09-01

    Bullous pemphigoid is a rare, autoimmune blistering disease. Its clinical presentation is tense blisters that may arise on normal-appearing or erythematous skin. Bullous pemphigoid refractory to systemic corticosteroids in combination with immunosuppressants such as azathioprine and mycophenolate mofetil may benefit from adjuvant high-dose intravenous immunoglobulin (IVIg). We describe a particular case with an unusual clinical presentation unresponsive to systemic corticosteroids plus azathioprine, in which the addition of high-dose IVIg was successful. The combined therapy of systemic corticosteroids and azathioprine plus high-dose IVIg can be an option in refractory cases due to its efficiency and tolerability.

  12. Regular self-microstructuring on CR39 using high UV laser dose

    Energy Technology Data Exchange (ETDEWEB)

    Parvin, P., E-mail: parvin@aut.ac.ir [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran (Iran, Islamic Republic of); Refahizadeh, M. [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran (Iran, Islamic Republic of); Mortazavi, S.Z. [Physics Department, Faculty of Science, Imam Khomeini International University, P.O. Box 34149-16818, Qazvin (Iran, Islamic Republic of); Silakhori, K. [Laser and Optics Research School, P.O. Box 11365-8486, Tehran (Iran, Islamic Republic of); Mahdiloo, A. [Mining and Metallurgical Engineering Department, Amirkabir University of Technology, P.O. Box 1591634311, Tehran (Iran, Islamic Republic of); Aghaii, P. [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran (Iran, Islamic Republic of)

    2014-02-15

    The UV laser induced replicas in the form of self-lining microstructures are created by high dose (with high fluence) ArF laser irradiation on CR39. Microstructures as the self-induced contours, in the form of concentric circles, appear when the laser fluence is well above the ablation threshold. It leads to the regular periodic parallel lines, i.e. circles with large radii having spatial separation 100–200 nm and line width 300–600 nm, where the number of shots increases to achieve higher UV doses. The surface wettability is also investigated after laser texturing to exhibit that a notable hydrophilicity takes place at high doses.

  13. High-power diode-end-pumped Tm:YLF slab laser delivering 189 W at 1890 nm

    CSIR Research Space (South Africa)

    Koen, W

    2010-09-01

    Full Text Available The authors present a high-power Tm:YLF slab laser double-end-pumped by two 300 W laser diode stacks. The resonator was designed such that the laser emitted at 1890 nm instead of the conventional operating wavelength of 1912 nm. At full incident...

  14. Effectiveness of a peer-delivered dissonance-based program in reducing eating disorder risk factors in high school girls.

    Science.gov (United States)

    Ciao, Anna C; Latner, Janet D; Brown, Krista E; Ebneter, Daria S; Becker, Carolyn B

    2015-09-01

    This pilot study investigated the feasibility, acceptability, and effectiveness of a peer-led dissonance-based eating disorders (ED) prevention/risk factor reduction program with high school girls. Ninth grade girls (n = 50) received the peer-led program within the school curriculum. A quasi-experimental design was used to assess changes in ED risk factors preintervention and postintervention compared with waitlist control. Participants were followed through 3-month follow-up. Peer-leader adherence to an intervention manual tailored for this age group was high. The intervention was rated as highly acceptable, with a large proportion of participants reporting that they enjoyed the program and learned and applied new information. Intervention participants exhibited significantly greater pre-post reductions in a majority of risk-factor outcomes compared to waitlist controls. When groups were combined to assess program effects over time there were significant pre-post reductions in a majority of outcomes that were sustained through 3-month follow-up. This pilot study provides tentative support for the effectiveness of using peer leaders to implement an empirically supported ED risk factor reduction program in a high school setting. Additional research is needed to replicate results in larger, better-controlled trials with longer follow-up. © 2015 Wiley Periodicals, Inc.

  15. Optimization of the Radiation Hardness of Silicon Pixel Sensors for High X-ray Doses using TCAD Simulations

    CERN Document Server

    Schwandt, J; Klanner, R; Pintilie, I; Zhang, J

    2011-01-01

    The European X-ray Free Electron Laser (XFEL) will deliver 27000 fully coherent, high brilliance X-ray pulses per second each with a duration below 100 fs. This will allow the recording of diffraction patterns of single molecules and the study of ultra-fast processes. One of the detector systems under development for the XFEL is the Adaptive Gain Integrating Pixel Detector (AGIPD), which consists of a pixel array with readout ASICs bump-bonded to a silicon sensor with pixels of 200 {\\mu}m \\times 200 {\\mu}m. The particular requirements for the detector are a high dynamic range (0, 1 up to 10E5 12 keV photons/XFEL-pulse), a fast read-out and radiation tolerance up to doses of 1 GGy of 12 keV X-rays for 3 years of operation. At this X-ray energy no bulk damage in silicon is expected. However fixed oxide charges in the SiO2 layer and interface traps at the Si-SiO2 interface will build up. As function of the 12 keV X-ray dose the microscopic defects in test structures and the macro- scopic electrical properties of...

  16. Acute cognitive effects of high doses of dextromethorphan relative to triazolam in humans

    Science.gov (United States)

    Carter, Lawrence P.; Reissig, Chad J.; Johnson, Matthew W.; Klinedinst, Margaret A.; Griffiths, Roland R.

    2012-01-01

    BACKGROUND Although concerns surrounding high-dose dextromethorphan (DXM) abuse have recently increased, few studies have examined the acute cognitive effects of high doses of DXM. The aim of this study was to compare the cognitive effects of DXM with those of triazolam and placebo. METHODS Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg /70 kg), and placebo were administered p.o. to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Effects on cognitive performance were examined at baseline and after drug administration for up to 6 hours. RESULTS Both triazolam and DXM produced acute impairments in attention, working memory, episodic memory, and metacognition. Impairments observed following doses of 100-300 mg/70 kg DXM were generally smaller in magnitude than those observed after 0.5 mg/70 kg triazolam. Doses of DXM that impaired performance to the same extent as triazolam were in excess of 10-30 times the therapeutic dose of DXM. CONCLUSION The magnitude of the doses required for these effects and the absence of effects on some tasks within the 100-300 mg/70 kg dose range of DXM, speak to the relatively broad therapeutic window of over-the-counter DXM preparations when used appropriately. However, the administration of supratherapeutic doses of DXM resulted in acute cognitive impairments on all tasks that were examined. These findings are likely relevant to cases of high-dose DXM abuse. PMID:22989498

  17. Measurement of the Space Radiation Dose for the Flight Aircrew at High-Altitude

    Science.gov (United States)

    Lee, Jaewon; Park, Inchun; Kim, Junsik; Lee, Jaejin; Hwang, Junga; Kim, Young-chul

    2014-03-01

    This paper describes an experimental approach to evaluate the effective doses of space radiations at high-altitude by combining the measured data from the Liulin-6K spectrometer loaded onto the air-borne RC-800 cockpit and the calculated data from CARI-6M code developed by FAA. In this paper, 15 exposed dose experiments for the flight missions at a highaltitude above 10 km and 3 experiments at a normal altitude below 4 km were executed over the Korean Peninsula in 2012. The results from the high-altitude flight measurements show a dramatic change in the exposed doses as the altitude increases. The effective dose levels (an average of 15.27 mSv) of aircrew at the high-altitude are an order of magnitude larger than those (an average of 0.30 mSv) of the normal altitude flight. The comparison was made between the measure dose levels and the calculated dose levels and those were similar each other. It indicates that the annual dose levels of the aircrew boarding RC- 800 could be above 1 mSv. These results suggest that a proper procedure to manage the exposed dose of aircrew is required for ROK Air Force.

  18. Catalytic Enantioselective Olefin Metathesis in Natural Product Synthesis. Chiral Metal-Based Complexes that Deliver High Enantioselectivity and More

    Science.gov (United States)

    Malcolmson, Steven J.; Meek, Simon J.; Zhugralin, Adil R.

    2012-01-01

    Chiral olefin metathesis catalysts enable chemists to access enantiomerically enriched small molecules with high efficiency; synthesis schemes involving such complexes can be substantially more concise than those that would involve enantiomerically pure substrates and achiral Mo alkylidenes or Ru-based carbenes. The scope of research towards design and development of chiral catalysts is not limited to discovery of complexes that are merely the chiral versions of the related achiral variants. A chiral olefin metathesis catalyst, in addition to furnishing products of high enantiomeric purity, can offer levels of efficiency, product selectivity and/or olefin stereoselectivity that are unavailable through the achiral variants. Such positive attributes of chiral catalysts (whether utilized in racemic or enantiomerically enriched form) should be considered as general, applicable to other classes of transformations. PMID:19967680

  19. The effects of high dose and highly fractionated radiation on distraction osteogenesis in the murine mandible.

    Science.gov (United States)

    Monson, Laura A; Cavaliere, Christi M; Deshpande, Sagar S; Ayzengart, Alexander L; Buchman, Steven R

    2012-09-07

    The ability of irradiated tissue to support bony growth remains poorly defined, although there are anecdotal cases reported showing mixed results for the use of mandibular distraction osteogenesis after radiation for head and neck cancer. Many of these reports lack objective measures that would allow adequate analysis of outcomes or efficacy. The purpose of this experiment was to utilize a rat model of mandibular distraction osteogenesis after high dose and highly fractionated radiation therapy and to evaluate and quantify distracted bone formation under these conditions. Male Sprague-Dawley rats underwent 12 fractions of external beam radiation (48 Gray) of the left mandible. Following a two week recovery period, an external frame distractor was applied and gradual distraction of the mandible was performed. Tissue was harvested after a twenty-eight day consolidation period. Gross, radiologic and histological evaluations were undertaken. Those animals subjected to pre-operative radiation showed severe attenuation of bone formation including bone atrophy, incomplete bridging of the distraction gap, and gross bony defects or non-union. Although physical lengthening was achieved, the irradiated bone consistently demonstrated marked damaging effects on the normal process of distraction osteogenesis. This murine model has provided reliable evidence of the injurious effects of high dose radiation on bone repair and regeneration in distraction osteogenesis utilizing accurate and reproducible metrics. These results can now be used to assist in the development of therapies directed at mitigating the adverse consequences of radiation on the regeneration of bone and to optimize distraction osteogenesis so it can be successfully applied to post-oncologic reconstruction.

  20. High-order noise analysis for low dose iterative image reconstruction methods: ASIR, IRIS, and MBAI

    Science.gov (United States)

    Do, Synho; Singh, Sarabjeet; Kalra, Mannudeep K.; Karl, W. Clem; Brady, Thomas J.; Pien, Homer

    2011-03-01

    Iterative reconstruction techniques (IRTs) has been shown to suppress noise significantly in low dose CT imaging. However, medical doctors hesitate to accept this new technology because visual impression of IRT images are different from full-dose filtered back-projection (FBP) images. Most common noise measurements such as the mean and standard deviation of homogeneous region in the image that do not provide sufficient characterization of noise statistics when probability density function becomes non-Gaussian. In this study, we measure L-moments of intensity values of images acquired at 10% of normal dose and reconstructed by IRT methods of two state-of-art clinical scanners (i.e., GE HDCT and Siemens DSCT flash) by keeping dosage level identical to each other. The high- and low-dose scans (i.e., 10% of high dose) were acquired from each scanner and L-moments of noise patches were calculated for the comparison.

  1. MCz diode response as a high-dose gamma radiation dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Camargo, F. [Instituto de Pesquisas Energeticas e Nucleares-IPEN-CNEN/SP, Caixa Postal 11049 - 05422 970 Sao Paulo/SP (Brazil); Goncalves, J.A.C. [Instituto de Pesquisas Energeticas e Nucleares-IPEN-CNEN/SP, Caixa Postal 11049 - 05422 970 Sao Paulo/SP (Brazil); Depto. de Fisica, Pontificia Universidade Catolica de Sao Paulo-PUC/SP, Rua Marques de Paranagua no 111-01303 050 Sao Paulo/SP (Brazil); Khoury, H.J. [Nuclear Energy Department, Universidade Federal de Pernambuco-UFPE, Av. Prof. Luiz Freire no 1000-50740 540 Recife/PE (Brazil); Napolitano, C.M. [Instituto de Pesquisas Energeticas e Nucleares-IPEN-CNEN/SP, Caixa Postal 11049 - 05422 970 Sao Paulo/SP (Brazil); Haerkoenen, J. [Helsinki Institute of Physics-HIP, University of Helsinki, 00014 Helsinki (Finland); Bueno, C.C. [Instituto de Pesquisas Energeticas e Nucleares-IPEN-CNEN/SP, Caixa Postal 11049 - 05422 970 Sao Paulo/SP (Brazil); Depto. de Fisica, Pontificia Universidade Catolica de Sao Paulo-PUC/SP, Rua Marques de Paranagua no 111-01303 050 Sao Paulo/SP (Brazil)], E-mail: ccbueno@ipen.br

    2008-02-15

    This work presents the preliminary results obtained with a high-resistivity magnetic Czochralski (MCz) silicon diode processed at the Helsinki Institute of Physics as a high-dose gamma dosimeter in radiation processing. The irradiation was performed using a {sup 60}Co source (Gammacell 220, MDS Nordion) within total doses from 100 Gy up to 3 kGy at a dose rate of 3 kGy/h. In this interval, the dosimetric response of the diode is linear with a correlation coefficient (r{sup 2}) higher than 0.993. However, without any irradiation procedure, the device showed a small sensitivity dependence on the accumulated dose. For total dose of 3 kGy, the observed decrease was about 2%. To clarify the origin of this possible radiation damage effect, some studies are under way.

  2. High-dose insulin therapy in beta-blocker and calcium channel-blocker poisoning.

    Science.gov (United States)

    Engebretsen, Kristin M; Kaczmarek, Kathleen M; Morgan, Jenifer; Holger, Joel S

    2011-04-01

    INTRODUCTION. High-dose insulin therapy, along with glucose supplementation, has emerged as an effective treatment for severe beta-blocker and calcium channel-blocker poisoning. We review the experimental data and clinical experience that suggests high-dose insulin is superior to conventional therapies for these poisonings. PRESENTATION AND GENERAL MANAGEMENT. Hypotension, bradycardia, decreased systemic vascular resistance (SVR), and cardiogenic shock are characteristic features of beta-blocker and calcium-channel blocker poisoning. Initial treatment is primarily supportive and includes saline fluid resuscitation which is essential to correct vasodilation and low cardiac filling pressures. Conventional therapies such as atropine, glucagon and calcium often fail to improve hemodynamic status in severely poisoned patients. Catecholamines can increase blood pressure and heart rate, but they also increase SVR which may result in decreases in cardiac output and perfusion of vascular beds. The increased myocardial oxygen demand that results from catecholamines and vasopressors may be deleterious in the setting of hypotension and decreased coronary perfusion. METHODS. The Medline, Embase, Toxnet, and Google Scholar databases were searched for the years 1975-2010 using the terms: high-dose insulin, hyperinsulinemia-euglycemia, beta-blocker, calcium-channel blocker, toxicology, poisoning, antidote, toxin-induced cardiovascular shock, and overdose. In addition, a manual search of the Abstracts of the North American Congress of Clinical Toxicology and the Congress of the European Association of Poisons Centres and Clinical Toxicologists published in Clinical Toxicology for the years 1996-2010 was undertaken. These searches identified 485 articles of which 72 were considered relevant. MECHANISMS OF HIGH-DOSE INSULIN BENEFIT. There are three main mechanisms of benefit: increased inotropy, increased intracellular glucose transport, and vascular dilatation. EFFICACY OF HIGH-DOSE

  3. HIGH AND LOW DOSE IVIG THERAPY IN GUILLAIN-BARRE SYNDROME CHILDREN: A COMPARISON

    Directory of Open Access Journals (Sweden)

    P. KARIMZADEH MD

    2009-05-01

    Full Text Available Objective:Acute inflammatory demyelinating peripheral neuropathy (Guillain-Barre-Syndrome is by far the most common cause of immune-medicated peripheral nervous system disease in children; with the near disappearance of poliomyelitis, GBS is responsible for the great majority of cases of acute flaccid paralysis. So far, in several controlled studies, corticosteroids, plasmapheresis and IVIG have been utilized in pediatric patients, afflicted with GBS. Regarding IVIG therapy, two methods have been used; the high dose (1 gr/kg/day for 2 days, and the low dose (400mg/kg/day for 5 days. Review of literature shows that a faster rate of recovery can be accomplished in patients who receive total dose of IVIG in 2 days as compared to the dose being given over 5 days.Materials & Methods:In this study we have compared these two types of treatment in an investigation, conducted in the Mofid Children Hospital on pediatric patients who had sudden onset of acute flaccid  paralysis, and were diagnosed as having GBS. Based on histories, physical examination and electrodiagnosis, subjects were divided in two groups, the high dose IVIG treatment, 1gr/kg/day for 2 days (experimental group, and the low dose IVIG treatment, 400 mg/kg/day for 5 days (control group. Statistical analyses were then carried out using the appropriate software.Results:Result of this study showed a faster rate of recovery for patients in the high dose IVIG group; in this group duration of weakness of limbs was shorter and returning of DTR was faster than in controls. In fact, in this type of treatment, the relationship between high dose IVIG therapy and drug side effects was not significant.Conclusion:Base upon the finding in the present study, we conclude that the high dose IVIG therapy is superior to low dose, in view of faster duration of recovery and shorter hospital stay. Also we may infer that shorter hospital stay could be a factor in reducing of more nasocomial infection. In

  4. A motorized pellet dispenser to deliver high intensity training of the single pellet reaching and grasping task in rats.

    Science.gov (United States)

    Torres-Espín, Abel; Forero, Juan; Schmidt, Emma K A; Fouad, Karim; Fenrich, Keith K

    2017-08-25

    The single pellet reaching and grasping (SPG) task is widely used to study forelimb motor performance in rodents and to provide rehabilitation after neurological disorders. Nonetheless, the time necessary to train animals precludes its use in settings where high-intensity training is required. In the current study, we developed a novel high-intensity training protocol for the SPG task based on a motorized pellet dispenser and a dual-window enclosure. We tested the protocol in naive adult rats and found 1) an increase in the intensity of training without increasing the task time and without affecting the overall performance of the animals, 2) a reduction in the variability within and between experiments in comparison to manual SPG training, and 3) a reduction in the time required to conduct experiments. In summary, we developed and tested a novel protocol for SPG training that provides higher-intensity training while reducing the variability of results observed with other protocols. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Possible effects of delivering methionine to broilers in drinking water at constant low and high environmental temperatures

    Directory of Open Access Journals (Sweden)

    Sahin Cadirci

    2014-02-01

    Full Text Available An experiment was conducted to study the effects of water-soluble DL-methionine supplied through water and feed on the performance and carcass yield of broilers housed at two constant temperatures from 21 to 42 days of age. Birds were housed in two rooms (240 birds per room with temperatures set at 21±2 and 30±2oC, respectively. Birds were divided into five groups of equal number within each room and fed five different diets (G1-G5. A low-methionine basal diet without supplemental methionine was fed to group 1 (G1. The basal diet was fortified with 0.025% or 0.050% methionine, either in feed (G2 and G3, respectively, or in a water solution (G4 and G5, respectively. Mortality was not significantly altered by any dietary treatment. Neither feed nor water intake was affected adversely by DLmethionine inclusion in drinking water. Housing at high temperature showed deleterious effect on birds’ weight gain. Additional methionine intake both in feed and water was associated with significantly heavier body weight, weight gain and feed conversion ratio, than the basal diet at low and high environmental temperature. Carcass yields, as a percentage of live body weight, were not affected by dietary treatment. The results indicate that, under the experimental conditions, DLmethionine provided in drinking water can be effectively assimilated by broilers, at least from 21 to 42 days of age.

  6. "EFFECT OF HIGH VERSUS LOW DOSES OF HUMAN RECOMBINANT ERYTHROPOIETIN ON THE ANEMIA OF PREMATURITY"

    Directory of Open Access Journals (Sweden)

    A. Mohammadzadeh

    2005-05-01

    Full Text Available Recombinant human erythropoietin (rh-EPO is known to accelerate erythropoiesis in preterm infants. The purpose of this study was to compare the effectiveness of early treatment with two doses of rh-EPO (high vs. low dose in the management of anemia of prematurity. Twenty preterm infants with hematocrit (Hct < 30% when infant’s age was between 2 to 3 weeks after birth or Hct <25% when infant’s age was more than 3 weeks after birth, were divided randomly in two groups, each group including 10 babies. Infants in high dose group received 500 u/kg rh-EPO twice per week and the low dose group received 500 u/kg rh-EPO weekly. All infants were fed human milk supplemented with enteral iron. Hematocrit and reticulocyte counts were determined for each infant at the start of the study, 3 days after start of treatment and one week after the end of treatment. The means of gestational age in high dose and low dose groups were 31.4 ± 2.2 and 31.3±2.0 weeks, respectively. Means of birth weight in high dose and low dose groups were 1366 ± 243 and 1438±249 gr, respectively. The two groups were significantly different in reticulocyte count at 3 days after treatment (P = 0.047 and in hematocrit at the end of study (P < 0.0001. We concluded the early treatment of anemia of prematurity with high dose rh-EPO with supplemental iron significantly increases hematocrit and reticulocyte in preterm infants and reduce the need for blood transfusion in these high risk neonates.

  7. High-dose dosimetry of beta rays using blue beryl dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Lucas S. do, E-mail: lsatiro@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Watanabe, Shigueo; Bittencour, Jose F., E-mail: Lacifid@if.usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Fisica. Departamento de Fisica Nuclear

    2015-07-01

    High dose radiation is widely used in industrial applications as sterilization of medical products, improvement of materials properties, color enhancement of jewelry stones, etc. The radiation dosimetry of high doses is quite important for these applications. In this work we have investigated the usage of blue beryl crystal also known as aquamarine in high dose dosimetry of beta rays. Some works have shown that silicate minerals exhibit a good Thermoluminescent response when irradiated up to 2000 kGy of gamma rays. Here, we have produced small beryl pellets of approximately 5 mm in diameter and 3 mm thickness to measure high doses of beta rays produced at an electron accelerator at IPEN. Twelve beryl dosimeters were made and six of them were irradiated from 10kGy up to 100 kGy. The technique used to create a calibration curve was the thermoluminescence using the glow peak at 310°C. (author)

  8. High-dose-rate brachytherapy with local injection of bleomycin for N0 oral tongue cancer. Possibilities of the control of tumor implant by inserting applicators and the decrease in tumor dose

    Energy Technology Data Exchange (ETDEWEB)

    Ohga, Saiji; Uehara, Satoru [National Kyushu Medical Center Hospital, Fukuoka (Japan); Miyoshi, Makoto [Kitakyushu Municipal Medical Center Hospital, Fukuoka (Japan); Jingu, Kenichi [Fukuoka Univ. (Japan). School of Medicine

    2003-01-01

    Twenty-eight patients with N0 oral tongue cancer were treated with high-dose-rate (HDR) interstitial brachytherapy combined with local injection of bleomycin between December 1997 and June 2001 at the Department of Radiology, National Kyushu Medical Center Hospital. A median dose of 5 mg of bleomycin was injected locally, and 16-20 Gy was delivered to the area surrounding applicators for control of the tumor implant during the initial two days. The two-year local recurrence-free survival rate was 96% [T1, 2: 100% (8/8, 15/15), T3: 80% (4/5)]. The two-year secondary neck node metastasis rate was 7.1% [T1: 12.5% (1/8), T2: 6.7% (1/15), T3: 0% (0/5)]. There were no tumor implants in any patients. We tried to decrease the minimal tumor dose step by step. The groups with median minimal tumor doses of 60 Gy, 50 Gy, and 40 Gy had local recurrence rates of 12.5% (1/8), 0% (0/14), and 0% (0/6), respectively. Local recurrence rates were not increased by decreasing the minimal tumor dose. Two patients (7%) had secondary neck node metastasis. Late adverse effects were tongue ulcer: 11% (3/28), oral floor ulcer: 4% (1/28), and osteonecrosis: 4% (1/28). These results suggest that control of the tumor implant and the decrease in minimal tumor dose below 60 Gy may be possible with the local injection of bleomycin and delivery of doses to the area surrounding the applicators when N0 tongue cancer is treated using {sup 192}Ir-HDR brachytherapy. (author)

  9. Delivering the promise of the Decade of Vaccines: opportunities and challenges in the development of high quality new vaccines.

    Science.gov (United States)

    Keith, Jacqueline A; Agostini Bigger, Laetitia; Arthur, Phyllis A; Maes, Edith; Daems, Rutger

    2013-04-18

    The Decade of Vaccines (DoV) initiative, launched in 2010, has as its mission "to extend, by 2020 and beyond, the full benefits of immunization to all people, regardless of where they are born, who they are, or where they live". Through their life-saving vaccines, the research-based vaccine companies represented by the International Federation of Pharmaceutical Manufacturers & Associations (IFPMA) and the Biotechnology Industry Organization (BIO) make a major contribution toward this vision. In this article, we begin by summarizing progress made over the past three decades in research and development (R&D) of new and future vaccines, and identify the opportunities and challenges faced by the research-based vaccine industry. We then review the Global Vaccine Action Plan (GVAP) and provide IFPMA and BIO consensus perspectives on its six strategic objectives. Finally, we identify policy measures to support R&D of, and access to, high-quality, innovative vaccines.

  10. Anti-Inflammatory Properties of Low and High Doxycycline Doses: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    Roberta Di Caprio

    2015-01-01

    Full Text Available Doxycycline is used to treat infective diseases because of its broadspectrum efficacy. High dose administration (100 or 200 mg/day is often responsible for development of bacterial resistances and endogenous flora alterations, whereas low doses (20–40 mg/day do not alter bacteria susceptibility to antibiotics and exert anti-inflammatory activities. In this study, we wanted to assess the efficacy of both low and high doxycycline doses in modulating IL-8, TNF-α, and IL-6 gene expression in HaCaT cells stimulated with LPS. Three experimental settings were used, differing in the timing of doxycycline treatment in respect to the insult induced by LPS: pretreatment, concomitant, and posttreatment. Low doses were more effective than high doses in modulating gene expression of LPS-induced proinflammatory cytokines (IL-8, TNF-α, and IL-6, when added before (pretreatment or after (posttreatment LPS stimulation. This effect was not appreciated when LPS and doxycycline were simultaneously added to cell cultures: in this case high doses were more effective. In conclusion, our in vitro study suggests that low doxycycline doses could be safely used in chronic or acute skin diseases in which the inflammatory process, either constantly in progress or periodically recurring, has to be prevented or controlled.

  11. Anti-Inflammatory Properties of Low and High Doxycycline Doses: An In Vitro Study

    Science.gov (United States)

    Di Caprio, Roberta; Di Costanzo, Luisa; Monfrecola, Giuseppe

    2015-01-01

    Doxycycline is used to treat infective diseases because of its broadspectrum efficacy. High dose administration (100 or 200 mg/day) is often responsible for development of bacterial resistances and endogenous flora alterations, whereas low doses (20–40 mg/day) do not alter bacteria susceptibility to antibiotics and exert anti-inflammatory activities. In this study, we wanted to assess the efficacy of both low and high doxycycline doses in modulating IL-8, TNF-α, and IL-6 gene expression in HaCaT cells stimulated with LPS. Three experimental settings were used, differing in the timing of doxycycline treatment in respect to the insult induced by LPS: pretreatment, concomitant, and posttreatment. Low doses were more effective than high doses in modulating gene expression of LPS-induced proinflammatory cytokines (IL-8, TNF-α, and IL-6), when added before (pretreatment) or after (posttreatment) LPS stimulation. This effect was not appreciated when LPS and doxycycline were simultaneously added to cell cultures: in this case high doses were more effective. In conclusion, our in vitro study suggests that low doxycycline doses could be safely used in chronic or acute skin diseases in which the inflammatory process, either constantly in progress or periodically recurring, has to be prevented or controlled. PMID:25977597

  12. [High-dose chemotherapy as a strategy to overcome drug resistance in solid tumors].

    Science.gov (United States)

    Selle, Frédéric; Gligorov, Joseph; Soares, Daniele G; Lotz, Jean-Pierre

    2016-10-01

    The concept of high-doses chemotherapy was developed in the 1980s based on in vitro scientific observations. Exposure of tumor cells to increasing concentrations of alkylating agents resulted in increased cell death in a strong dose-response manner. Moreover, the acquired resistance of tumor cells could be overcome by dose intensification. In clinic, dose intensification of alkylating agents resulted in increased therapeutic responses, however associated with significant hematological toxicity. Following the development of autologous stem cells transplantation harvesting from peripheral blood, the high-doses of chemotherapy, initially associated with marked toxic effects, could be more easily tolerated. As a result, the approach was evaluated in different types of solid tumors, including breast, ovarian and germ cell tumors, small cell lung carcinoma, soft tissue sarcomas and Ewing sarcoma. To date, high-doses chemotherapy with hematopoietic stem cells support is only used as a salvage therapy to treat poor prognosis germ cell tumors patients with chemo-sensitive disease. Regarding breast and ovarian cancer, high-doses chemotherapy should be considered only in the context of clinical trials. However, intensive therapy as an approach to overcome resistance to standard treatments is still relevant. Numerous efforts are still ongoing to identify novel therapeutic combinations and active treatments to improve patients' responses.

  13. Measurement of photoneutron dose produced by wedge filters of a high energy linac using polycarbonate films.

    Science.gov (United States)

    Hashemi, Seyed Mehdi; Hashemi-Malayeri, Bijan; Raisali, Gholamreza; Shokrani, Parvaneh; Sharafi, Ali Akbar; Torkzadeh, Falamarz

    2008-05-01

    Radiotherapy represents the most widely spread technique to control and treat cancer. To increase the treatment efficiency, high energy linacs are used. However, applying high energy photon beams leads to a non-negligible dose of neutrons contaminating therapeutic beams. In addition, using conventional linacs necessitates applying wedge filters in some clinical conditions. However, there is not enough information on the effect of these filters on the photoneutrons produced. The aim of this study was to investigate the change of photoneutron dose equivalent due to the use of linac wedge filters. A high energy (18 MV) linear accelerator (Elekta SL 75/25) was studied. Polycarbonate films were used to measure the dose equivalent of photoneutrons. After electrochemical etching of the films, the neutron dose equivalent was calculated using Hp(10) factor, and its variation on the patient plane at 0, 5, 10, 50 and 100 cm from the center of the X-ray beam was determined. By increasing the distance from the center of the X-ray beam towards the periphery, the photoneutron dose equivalent decreased rapidly for the open and wedged fields. Increasing of the field size increased the photoneutron dose equivalent. The use of wedge filter increased the proportion of the neutron dose equivalent. The increase can be accounted for by the selective absorption of the high energy photons by the wedge filter.

  14. High-Dose and High-Frequency Lanreotide Autogel in Acromegaly: A Randomized, Multicenter Study.

    Science.gov (United States)

    Giustina, Andrea; Mazziotti, Gherardo; Cannavò, Salvatore; Castello, Roberto; Arnaldi, Giorgio; Bugari, Giovanna; Cozzi, Renato; Ferone, Diego; Formenti, Anna Maria; Gatti, Enza; Grottoli, Silvia; Maffei, Pietro; Maffezzoni, Filippo; Montini, Marcella; Terzolo, Massimo; Ghigo, Ezio

    2017-07-01

    Increase in drug frequency or dose is recommended for acromegaly patients with partial response to long-acting somatostatin receptor ligands (SRLs). However, the efficacy and safety data with lanreotide (LAN) Autogel (LAN-ATG) at high dose (HD) or high frequency (HF) are still scanty. To evaluate the biochemical efficacy and safety of HF and HD LAN-ATG in patients with active acromegaly. Twenty-four-week prospective, multicenter, randomized, open-label trial. Thirty patients with active acromegaly, partial responders to SRLs, were randomized to HF (120 mg/21 days; 15 patients) or HD (180 mg/28 days; 15 patients) LAN-ATG. Normalization of serum insulin-like growth factor-I (IGF-I) and reduction in random growth hormone (GH) values < 1.0 µg/L, reduction in serum IGF-I and GH from baseline, differences in biochemical response between HF and HD LAN-ATG, adverse events. IGF-I decreased significantly (P = 0.007) during the 24-week treatment, with greater decrease in HD (P = 0.03) vs HF group (P = 0.08). Normalization in IGF-I values occurred in 27.6% of patients (P = 0.016 vs baseline), without a significant difference between HF and HD groups (P = 0.59). The decrease in serum IGF-I significantly correlated with serum LAN values (P = 0.04), and normalization of IGF-I was predicted by baseline IGF-I values (P = 0.02). Serum GH values did not change significantly (P = 0.22). Overall, 19 patients (63.3%) experienced adverse events, all being mild to moderate and transient, without differences between the two therapeutic arms. HF and HD LAN-ATG regimens are effective in normalizing IGF-I values in about one-third of patients with active acromegaly inadequately controlled by long-term conventional SRLs therapy.

  15. Comparison of high-dose and low-dose insulin by continuous intravenous infusion in the treatment of diabetic ketoacidosis in children.

    Science.gov (United States)

    Burghen, G A; Etteldorf, J N; Fisher, J N; Kitabchi, A Q

    1980-01-01

    We studied the efficacy of low-dose (0.1 U/kg/h) and high-dose (1..0 U/kg/h) insulin, given randomly to children with diabetic ketoacidosis (DKA) by continuous intravenous infusion without a loading dose. Plasma glucose reached 250 mg/dl in 3.4 +/- 0.4 h with the high-dose insulin group compared with 5.4 +/- 0.5 h with the low-dose insulin group (P Hypokalemia (K insulin, with a slower rate of glucose decrease, is as effective as a high dose for the treatment of DKA in children with less incidence of hypokalemia and decreased potential for hypoglycemia.

  16. In-phantom neutron dose distribution for bladder cancer cases treated with high-energy photons

    Science.gov (United States)

    Khaled, N. E.; Attalla, E. M.; Ammar, H.; Khalil, W.

    2011-06-01

    This work presents an estimation of the neutron dose distribution for common bladder cancer cases treated with high-energy photons of 15 MV therapy accelerators. Neutron doses were measured in an Alderson phantom, using TLD 700 and 600 thermoluminescence dosimeters, resembling bladder cancer cases treated with high-energy photons from 15 MV LINAC and having a treatment plan using the four-field pelvic box technique. Thermal neutron dose distribution in the target area and the surrounding tissue was estimated. The sensitivity of all detectors for both gamma and neutrons was estimated and used for correction of the TL reading. TLD detectors were irradiated with a Co60 gamma standard source and thermal neutrons at the irradiation facility of the National Institute for Standards (NIS). The TL to dose conversion factor was estimated in terms of both Co60 neutron equivalent dose and thermal neutron dose. The dose distribution of photo-neutrons throughout each target was estimated and presented in three-dimensional charts and isodose curves. The distribution was found to be non-isotropic through the target. It varied from a minimum of 0.23 mSv/h to a maximum of 2.07 mSv/h at 6 cm off-axis. The mean neutron dose equivalent was found to be 0.63 mSv/h, which agrees with other published literature. The estimated average neutron equivalent to the bladder per administered therapeutic dose was found to be 0.39 mSv Gy-1, which is also in good agreement with published literature. As a consequence of a complete therapeutic treatment of 50 Gy high-energy photons at 15 MV, the total thermal neutron equivalent dose to the abdomen was found to be about 0.012 Sv.

  17. International VLBI Service for Geodesy and Astrometry - Delivering high-quality products and embarking on observations of the next generation

    Science.gov (United States)

    Nothnagel, A.; Artz, T.; Behrend, D.; Malkin, Z.

    2016-09-01

    The International VLBI Service for Geodesy and Astrometry (IVS) regularly produces high-quality Earth orientation parameters from observing sessions employing extensive networks or individual baselines. The master schedule is designed according to the telescope days committed by the stations and by the need for dense sampling of the Earth orientation parameters (EOP). In the pre-2011 era, the network constellations with their number of telescopes participating were limited by the playback and baseline capabilities of the hardware (Mark4) correlators. This limitation was overcome by the advent of software correlators, which can now accommodate many more playback units in a flexible configuration. In this paper, we describe the current operations of the IVS with special emphasis on the quality of the polar motion results since these are the only EOP components which can be validated against independent benchmarks. The polar motion results provided by the IVS have improved continuously over the years, now providing an agreement with IGS results at the level of 20-25 μ as in a WRMS sense. At the end of the paper, an outlook is given for the realization of the VLBI Global Observing System.

  18. VNARs: An Ancient and Unique Repertoire of Molecules That Deliver Small, Soluble, Stable and High Affinity Binders of Proteins

    Directory of Open Access Journals (Sweden)

    Caroline Barelle

    2015-09-01

    Full Text Available At 420 million years, the variable domain of New Antigen Receptors or VNARs are undoubtedly the oldest (and smallest antigen binding single domains identified in the vertebrate kingdom. Their role as an integral part of the adaptive immune system of sharks has been well established and has served to provide a greater understanding of the evolution of humoral immunity; their cellular components and processes as well as the underlying genetic organization and molecular control mechanisms. Intriguingly, unlike the variable domain of the camelid heavy chain antibodies or VHH, VNARs do not conform to all of the characteristic properties of classical antibodies with an ancestral origin that clearly distinguishes them from true immunoglobulin antibodies. However, this uniqueness of their origin only adds to their potential as next generation therapeutic biologics with their structural and functional attributes and commercial freedom all enhancing their profile and current success. In fact their small size, remarkable stability, molecular flexibility and solubility, together with their high affinity and selectivity for target, all reinforce the potential of these domains as drug candidates. The purpose of this review is to provide an overview of the existing basic biology of these unique domains, to highlight the drug-like properties of VNARs and describe current progress in their journey towards the clinic.

  19. International VLBI Service for Geodesy and Astrometry. Delivering high-quality products and embarking on observations of the next generation

    Science.gov (United States)

    Nothnagel, A.; Artz, T.; Behrend, D.; Malkin, Z.

    2017-07-01

    The International VLBI Service for Geodesy and Astrometry (IVS) regularly produces high-quality Earth orientation parameters from observing sessions employing extensive networks or individual baselines. The master schedule is designed according to the telescope days committed by the stations and by the need for dense sampling of the Earth orientation parameters (EOP). In the pre-2011 era, the network constellations with their number of telescopes participating were limited by the playback and baseline capabilities of the hardware (Mark4) correlators. This limitation was overcome by the advent of software correlators, which can now accommodate many more playback units in a flexible configuration. In this paper, we describe the current operations of the IVS with special emphasis on the quality of the polar motion results since these are the only EOP components which can be validated against independent benchmarks. The polar motion results provided by the IVS have improved continuously over the years, now providing an agreement with IGS results at the level of 20-25 μas in a WRMS sense. At the end of the paper, an outlook is given for the realization of the VLBI Global Observing System.

  20. Elastic stability of high dose neutron irradiated spinel

    Energy Technology Data Exchange (ETDEWEB)

    Li, Z.; Chan, S.K. [Argonne National Lab., Chicago, IL (United States); Garner, F.A. [Pacific Northwest Lab., Richland, WA (United States)] [and others

    1995-04-01

    The objective of this effort is to identify ceramic materials that are suitable for fusion reactor applications. Elastic constants (C{sub 11}, C{sub 12}, and C{sub 44}) of spinel (MgAl{sub 2}O{sub 4}) single crystals irradiated to very high neutron fluences have geen measured by an ultrasonic technique. Although results of a neutron diffraction study show that cation occupation sites are significantly changed in the irradiated samples, no measurable differences occurred in their elastic properties. In order to understand such behavior, the elastic properties of a variety of materials with either normal or inverse spinel structures were studied. The cation valence and cation distribution appear to have little influence on the elastic properties of spinel materials.

  1. High-dose Sulbactam Treatment for Ventilator-Associated Pneumonia Caused by Carbapenem-Resistant

    Directory of Open Access Journals (Sweden)

    In Beom Jeong

    2016-11-01

    Full Text Available Background Several antibiotics can be used to treat ventilator-associated pneumonia caused by carbapenem-resistant A. baumannii (CRAB-VAP including high-dose sulbactam. However, the effectiveness of high-dose sulbactam therapy is not well known. We report our experience with high-dose sulbactam for treatment of CRAB-VAP. Methods Medical records of patients with CRAB-VAP who were given high-dose sulbactam between May 2013 and June 2015 were reviewed. Results Fifty-eight patients with CRAB-VAP were treated with high-dose sulbactam. The mean age was 72.0 ± 15.2 years, and the acute physiology and chronic health evaluation II (APACHE II score was 15.1 ± 5.10 at the time of CRAB-VAP diagnosis. Early clinical improvement was observed in 65.5% of patients, and 30-day mortality was 29.3%. Early clinical failure (odds ratio [OR]: 8.720, confidence interval [CI]: 1.346-56.484; p = 0.023 and APACHE II score ≥ 14 at CRAB-VAP diagnosis (OR: 10.934, CI: 1.047-114.148; p = 0.046 were associated with 30-day mortality. Conclusions High-dose sulbactam therapy may be effective for the treatment of CRAB-VAP. However, early clinical failure was observed in 35% of patients and was associated with poor outcome.

  2. The enhanced healing of a high-risk, clean, sutured surgical incision by prophylactic negative pressure wound therapy as delivered by Prevena™ Customizable™: cosmetic and therapeutic results.

    Science.gov (United States)

    Scalise, Alessandro; Tartaglione, Caterina; Bolletta, Elisa; Calamita, Roberto; Nicoletti, Giovanni; Pierangeli, Marina; Grassetti, Luca; Di Benedetto, Giovanni

    2015-04-01

    According to the literature, incisional closure complications may range from postoperative surgical site infections, representing 17-22% of health care-associated infections, surgical wound dehiscence and formation of haematomas or seromas, and can lead to delayed or impaired incision healing. These kinds of situations are more common when wounds are closed under tension or in specific patient morbidities. Obesity, in particular, is associated with an impaired blood flow to tissues, predisposing the patient to increased risk of wound complications by various mechanisms. Incisional complications can become relevant economic burdens for health care systems because of an increase in the average length of hospital stay and readmissions, and additional medical and surgical procedures. Thus, a preventive therapy may have a critical role in the management of healing. Negative pressure wound therapy (NPWT) technology as delivered by Prevena™ Customizable™ (Kinetic Concepts Inc., San Antonio, TX) has recently been the focus of a new investigation, as a prophylactic measure to prevent complications via immediate postoperative application in high-risk, clean, closed surgical incisions. The authors present a 62-year-old class II obese female, who underwent bilateral inguinal dermolipectomy. Prophylactic NPWT as delivered by Prevena™ was performed successfully over surgical incisions. Cosmetic and therapeutic results are shown.

  3. Application of PK/PD modeling and simulation to dosing regimen optimization of high-dose human regular U-500 insulin.

    Science.gov (United States)

    de la Peña, Amparo; Ma, Xiaosu; Reddy, Shobha; Ovalle, Fernando; Bergenstal, Richard M; Jackson, Jeffrey A

    2014-07-01

    Pharmacokinetic/pharmacodynamic (PK/PD) studies of human regular U-500 insulin (U-500R) at high doses commonly used in clinical practice (>100 units) have not been performed. The current analysis applied PK/PD modeling/simulation to fit the data and simulate single-dose and steady-state PK/PD of U-500R high-dose regimens. Data from 3 single-dose euglycemic clamp studies in healthy obese and normal-weight patients, and normal-weight patients with type 1 diabetes were used to build the model. The model was sequential (PK inputs fed into PD component). PK was described using a 1-compartment model with first-order absorption and elimination. The model estimated separate absorption rate constants for U-500R and human regular U-100 insulin. The PD component used an effect compartment model, parameterized in terms of maximum pharmacologic effect (E(max)) and concentration to achieve 50% of E(max). The model described the data well. Steady-state PK for once-daily (QD), twice-daily (BID), or thrice-daily (TID) administration appeared to be reached 24 hours after the first dose. At steady-state, QD dosing showed the greatest fluctuations in PK/PD. BID dosing showed a gradual increase in insulin action with each dose and a fairly stable basal insulin effect. For TID dosing, activity was maintained throughout the dosing interval. PK/PD modeling/simulation of high U-500R doses supports BID or TID administration with an extended duration of activity relative to QD. TID dosing may provide slightly better full-day insulin effect. Additional PK/PD studies and randomized controlled trials of U-500R are needed to validate model predictions in patients with insulin-resistant diabetes requiring high-dose insulin.

  4. Comparison of Acute and Late Toxicities for Three Modern High-Dose Radiation Treatment Techniques for Localized Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Mohammed, Nasiruddin [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States); Kestin, Larry, E-mail: lkestin@beaumont.edu [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States); Ghilezan, Mihai; Krauss, Daniel; Vicini, Frank; Brabbins, Donald; Gustafson, Gary; Ye Hong; Martinez, Alavaro [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States)

    2012-01-01

    Purpose: We compared acute and late genitourinary (GU) and gastrointestinal (GI) toxicities in prostate cancer patients treated with three different high-dose radiation techniques. Methods and Materials: A total of 1,903 patients with localized prostate cancer were treated with definitive RT at William Beaumont Hospital from 1992 to 2006: 22% with brachytherapy alone (BT), 55% with image-guided external beam (EB-IGRT), and 23% external beam with high-dose-rate brachytherapy boost (EBRT+HDR). Median dose with BT was 120 Gy for LDR and 38 Gy for HDR (9.5 Gy Multiplication-Sign 4). Median dose with EB-IGRT was 75.6 Gy (PTV) to prostate with or without seminal vesicles. For EBRT+HDR, the pelvis was treated to 46 Gy with an additional 19 Gy (9.5 Gy Multiplication-Sign 2) delivered via HDR. GI and GU toxicity was evaluated utilizing the NCI-CTC criteria (v.3.0). Median follow-up was 4.8 years. Results: The incidences of any acute {>=} Grade 2 GI or GU toxicities were 35%, 49%, and 55% for BT, EB-IGRT, and EBRT+HDR (p < 0.001). Any late GU toxicities {>=} Grade 2 were present in 22%, 21%, and 28% for BT, EB-IGRT, and EBRT+HDR (p = 0.01), respectively. Patients receiving EBRT+HDR had a higher incidence of urethral stricture and retention, whereas dysuria was most common in patients receiving BT. Any Grade {>=}2 late GI toxicities were 2%, 20%, and 9% for BT, EB-IGRT, and EBRT+HDR (p < 0.001). Differences were most pronounced for rectal bleeding, with 3-year rates of 0.9%, 20%, and 6% (p < 0.001) for BT, EB-IGRT, and EBRT+HDR respectively. Conclusions: Each of the three modern high-dose radiation techniques for localized prostate cancer offers a different toxicity profile. These data can help patients and physicians to make informed decisions regarding radiotherapy for prostate andenocarcinoma.

  5. Polybutadiene and Styrene-Butadiene rubbers for high-dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Lucas N. [Instituto Federal de Educacao, Ciencia e Tecnologia de Goias-IFG,Campus Goiania, Goiania -GO (Brazil); Instituto de Pesquisas Energeticas e Nucleares -IPEN, Sao Paulo-SP (Brazil); Vieira, Silvio L. [Instituto de Fisica, Universidade Federal de Goias-UFG, Campus Samambaia, Goiania-GO (Brazil); Schimidt, Fernando [Instituto Federal de Educacao, Ciencia e Tecnologia de Goias-IFG,Campus Inhumas, Inhumas-GO (Brazil); Antonio, Patricia L.; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares -IPEN, Sao Paulo-SP (Brazil)

    2015-07-01

    Polybutadiene and Styrene-Butadiene are synthetical rubbers used widely for pneumatic tires manufacturing. In this research, the dosimeter characteristics of those rubbers were studied for application in high-dose dosimetry. The rubber samples were irradiated with doses of 10 Gy up to 10 kGy, using a {sup 60}Co Gamma Cell-220 system (dose rate of 1.089 kGy/h) and their readings were taken on a Fourier Transform Infrared Spectroscopy-FTIR system (model Frontier/Perkin Elmer). The ratios of two absorbance peaks were taken for each kind of rubber spectrum, Polybutadiene (1306/1130 cm{sup -1}) and Styrene-Butadiene (1449/1306 cm{sup -1}). The ratio calculated was used as the response to the irradiation, and is not uniform across the sample. From the results, it can be concluded for both rubbers: a) the dose-response curves may be useful for high-dose dosimetry (greater than 250 Gy); b) their response for reproducibility presented standard deviations lower than 2.5%; c) the relative sensitivity was higher for Styrene-Butadiene (1.86 kGy{sup -1}) than for Polybutadiene (1.81 kGy{sup -1}), d) for doses of 10 kGy to 200 kGy, there was no variation in the dosimetric response. Both types of rubber samples showed usefulness as high-dose dosimeters. (authors)

  6. HIGH DOSE FRACTION RADIOTHERAPY FOR MUCOSAL MALIGNANT MELANOMA OF THE HEAD AND NECK

    Institute of Scientific and Technical Information of China (English)

    Liu Xiuying; Li Huiling; Zheng Tianrong; Lin Xiangsong

    1998-01-01

    Objective:To evatuate the results of high dose fraction radiotherapy for mucosal malignant melanoma of the head and neck (HNMM). Methods: From 1984-1994, 35 patients with HNMM were enrolled in this study. Among them, 27 cases localized to the nasal cavity or para-nasal sinus, 8 to the oral cavity. All patients received high dose fraction radiotherapy (6--8 Gy/fraction)with the total dose ranged from 40 to 60 Gy. Results: The minimum follow-up was 2 years (ranged 2-7 years). The overall 3- and 5-year survival rate was 45.7% and 24%,respectively. Conclusion: High dose fraction radiotherapy is effective for local control of HNMM.

  7. Polycarbonate-based benzo-δ-sultam films for high-dose dosimetry in radiation processing

    Energy Technology Data Exchange (ETDEWEB)

    Feizi, Shazad [University of Tehran, Tehran (India). School of Chemistry; Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of). Radiation Application Research School; Ziaie, Farhood [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of). Radiation Application Research School; Ghandi, Mehdi [University of Tehran, Tehran (India). School of Chemistry

    2015-05-01

    In this work characteristics of the polycarbonate films with 20 μm in thickness containing different weight percentage of Benzo-δ-sultam were studied for use as a high dose dosimetry system in radiation processing facilities. The sensitivity of the dosimeters and the linearity of dose-response curves were investigated under {sup 60}Co γ-rays in a dose range of 0-100 kGy, and obtained results were compared with the commercial CTA and FWT film dosimeters. The results show that the absorbance at 348 nm depends linearly on the dose in the investigated dose range. The effects of pre-irradiation (shelf-life) and post-irradiation storage in dark and in indirect sunlight are also discussed. The results show that the dosimeters characteristics are stable within 1% at 25 C, 3 months after the irradiation.

  8. Computed tomography-guided interstitial high dose rate brachytherapy for centrally located liver tumours: a single institution study

    Energy Technology Data Exchange (ETDEWEB)

    Tselis, Nikolaos; Chatzikonstantinou, Georgios; Zamboglou, Nikolaos [Klinikum Offenbach, Department of Radiation Oncology, Offenbach am Main (Germany); Kolotas, Christos [Hirslanden Medical Center, Institute for Radiotherapy, Aarau (Switzerland); Milickovic, Natasa; Baltas, Dimos [Klinikum Offenbach, Department of Medical Physics and Engineering, Offenbach am Main (Germany)

    2013-08-15

    To evaluate the clinical outcome of computed tomography (CT)-guided interstitial (IRT) high-dose-rate (HDR) brachytherapy (BRT) in the treatment of unresectable primary and secondary liver malignancies. This report updates and expands our previously described experience with this treatment technique. Forty-one patients with 50 tumours adjacent to the liver hilum and bile duct bifurcation were treated in 59 interventions of CT-guided IRT HDR BRT. The tumours were larger than 4 cm with a median volume of 84 cm{sup 3} (38-1,348 cm{sup 3}). The IRT HDR BRT delivered a median total physical dose of 20.0 Gy (7.0-32.0 Gy) in twice daily fractions of median 7.0 Gy (4.0-10.0 Gy) in 19 patients and in once daily fractions of median 8.0 Gy (7.0-14.0 Gy) in 22 patients. With a median follow-up of 12.4 months, the local control for metastatic hepatic tumours was 89 %, 73 % and 63 % at 6, 12 and 18 months respectively. The local control for primary hepatic tumours was 90 %, 81 % and 50 % at 6, 12 and 18 months respectively. Severe side effects occurred in 5.0 % of interventions with no treatment-related deaths. CT-guided IRT HDR BRT is a promising procedure for the radiation treatment of centrally located liver malignancies. (orig.)

  9. Is High Dose Therapy Superior to Conventional Dose Therapy as Initial Treatment for Relapsed Germ Cell Tumors? The TIGER Trial

    Directory of Open Access Journals (Sweden)

    Darren R. Feldman, Robert Huddart, Emma Hall, Jörg Beyer, Thomas Powles

    2011-01-01

    Full Text Available Metastatic germ cell tumours (GCTs are usually cured with cisplatin based chemotherapy and standard treatment algorithms are established. However when this treatment fails and the disease relapses, standard treatment is much more uncertain. Both conventional dose therapy (CDT and high dose therapy (HDT are widely used, due to the lack of conclusive data supporting one specific approach. A recent retrospective analysis focusing on this population suggested a significant benefit for HDT. Retrospective analyses are prone to bias, and therefore while this data is provocative it is by no mean conclusive. For this reason the international community is supporting a prospective randomised trial in this area comparing CDT(TIP with sequential HDT (TICE. The planned open labelled randomised phase III study (TIGER is due to open in 2011 and will recruit 390 patients to detect a 13% difference in 2 year progression free survival (primary endpoint. It is hoped that this large study will conclusively resolve the uncertainty which currently exists.

  10. High dose rate versus low dose rate brachytherapy for oral cancer--a meta-analysis of clinical trials.

    Directory of Open Access Journals (Sweden)

    Zhenxing Liu

    Full Text Available OBJECTIVE: To compare the efficacy and safety of high dose rate (HDR and low dose rate (LDR brachytherapy in treating early-stage oral cancer. DATA SOURCES: A systematic search of MEDLINE, EMBASE and Cochrane Library databases, restricted to English language up to June 1, 2012, was performed to identify potentially relevant studies. STUDY SELECTION: Only randomized controlled trials (RCT and controlled trials that compared HDR to LDR brachytherapy in treatment of early-stage oral cancer (stages I, II and III were of interest. DATA EXTRACTION AND SYNTHESIS: Two investigators independently extracted data from retrieved studies and controversies were solved by discussion. Meta-analysis was performed using RevMan 5.1. One RCT and five controlled trials (607 patients: 447 for LDR and 160 for HDR met the inclusion criteria. The odds ratio showed no statistically significant difference between LDR group and HDR group in terms of local recurrence (OR = 1.12, CI 95% 0.62-2.01, overall mortality (OR = 1.01, CI 95% 0.61-1.66 and Grade 3/4 complications (OR = 0.86, CI 95% 0.52-1.42. CONCLUSIONS: This meta-analysis indicated that HDR brachytherapy was a comparable alternative to LDR brachytherapy in treatment of oral cancer. HDR brachytherapy might become a routine choice for early-stage oral cancer in the future.

  11. PLUTONIUM/HIGH-LEVEL VITRIFIED WASTE BDBE DOSE CALCULATION

    Energy Technology Data Exchange (ETDEWEB)

    D.C. Richardson

    2003-03-19

    In accordance with the Nuclear Waste Policy Amendments Act of 1987, Yucca Mountain was designated as the site to be investigated as a potential repository for the disposal of high-level radioactive waste. The Yucca Mountain site is an undeveloped area located on the southwestern edge of the Nevada Test Site (NTS), about 100 miles northwest of Las Vegas. The site currently lacks rail service or an existing right-of-way. If the Yucca Mountain site is found suitable for the repository, rail service is desirable to the Office of Civilian Waste Management (OCRWM) Program because of the potential of rail transportation to reduce costs and to reduce the number of shipments relative to highway transportation. A Preliminary Rail Access Study evaluated 13 potential rail spur options. Alternative routes within the major options were also developed. Each of these options was then evaluated for potential land use conflicts and access to regional rail carriers. Three potential routes having few land use conflicts and having access to regional carriers were recommended for further investigation. Figure 1-1 shows these three routes. The Jean route is estimated to be about 120 miles long, the Carlin route to be about 365 miles long, and Caliente route to be about 365 miles long. The remaining ten routes continue to be monitored and should any of the present conflicts change, a re-evaluation of that route will be made. Complete details of the evaluation of the 13 routes can be found in the previous study. The DOE has not identified any preferred route and recognizes that the transportation issues need a full and open treatment under the National Environmental Policy Act. The issue of transportation will be included in public hearings to support development of the Environmental Impact Statement (EIS) proceedings for either the Monitored Retrievable Storage Facility or the Yucca Mountain Project or both.

  12. Influence of adjacent low-dose fields on tolerance to high doses of protons in rat cervical spinal cord

    NARCIS (Netherlands)

    Bijl, HP; van Luijk, P; Coppes, RP; Schippers, JM; Konings, AWT; van der Kogel, AJ

    2006-01-01

    Purpose: The dose-response relationship for a relatively short length (4 mm) of rat spinal cord has been shown to be significantly modified by adjacent low-dose fields. In an additional series of experiments, we have now established the dose-volume dependence of this effect. Methods and Materials: W

  13. Pit lake lime dosing: Assessment of the performance of the treatment based on a high-spatial resolution AUV survey

    Science.gov (United States)

    Delgado, Jordi; García-Morrondo, David; Cereijo-Arango, José Luis; Muñoz-Ibáñez, Andrea; Grande-García, Elisa; Rodríguez-Cedrún, Borja; Juncosa-Rivera, Ricardo

    2016-04-01

    The acidity of mine waters is typically corrected with passive (where possible) and/or active (i.e. chemical additions) systems. In the case of active treatments, lime dosing is a widespread technique due to the relatively ease of implementation and reduced operational costs. While neutralization of acidic waters is routinely performed in circulating water treatment facilities this is not so simple in open waters (e.g. pit lakes) because an efficient treatment requires the adequate distribution of the alkaline reagents throughout the volume of interest. To cope with this problem, a number of technical approaches have been proposed including active stirring (bubbling, etc.), surface spread diffusion, etc. In the early times of flooding of the Meirama mine, managers considered the necessity of lime dosing to correct the initially acidic mine waters. However, lake evolution proved that liming was not necessary and it was desirable to allow a reasonably unmanned evolution of the reclaimed system. In order to ensure that the lime dosing system is in good operative conditions in case of necessity, according to a prescribed time schedule to time mine managers put it in operation. That give us the opportunity to perform a large-scale "tracer" experiment useful to test the efficiency of wet lime dosing in a large water body. Dry lime, which is kept in a storage silo, is directly dosed over the channel of a small stream discharging in the lake. Therefore, stream water becomes saturated with lime and a pH of approximately 12.3. Stream water flows in cascade to the lake so that a certain potential and kinetic energy transfer is delivered to the lake. That promotes currents that enhance the re-distribution of the alkalinity load. In order to check for the distribution of alkaline water in the top body of the lake, an autonomous underwater vehicle (Yellow Spring Instruments Inc. EcoMapper AUV) was used. This device allows for the high- frequency simultaneous measurement of a

  14. Novel oxytocin receptor variants in laboring women requiring high doses of oxytocin.

    Science.gov (United States)

    Reinl, Erin L; Goodwin, Zane A; Raghuraman, Nandini; Lee, Grace Y; Jo, Erin Y; Gezahegn, Beakal M; Pillai, Meghan K; Cahill, Alison G; de Guzman Strong, Cristina; England, Sarah K

    2017-08-01

    Although oxytocin commonly is used to augment or induce labor, it is difficult to predict its effectiveness because oxytocin dose requirements vary significantly among women. One possibility is that women requiring high or low doses of oxytocin have variations in the oxytocin receptor gene. To identify oxytocin receptor gene variants in laboring women with low and high oxytocin dosage requirements. Term, nulliparous women requiring oxytocin doses of ≤4 mU/min (low-dose-requiring, n = 83) or ≥20 mU/min (high-dose-requiring, n = 104) for labor augmentation or induction provided consent to a postpartum blood draw as a source of genomic DNA. Targeted-amplicon sequencing (coverage >30×) with MiSeq (Illumina) was performed to discover variants in the coding exons of the oxytocin receptor gene. Baseline relevant clinical history, outcomes, demographics, and oxytocin receptor gene sequence variants and their allele frequencies were compared between low-dose-requiring and high-dose-requiring women. The Scale-Invariant Feature Transform algorithm was used to predict the effect of variants on oxytocin receptor function. The Fisher exact or χ(2) tests were used for categorical variables, and Student t tests or Wilcoxon rank sum tests were used for continuous variables. A P value labor induction and required prostaglandins. High-dose-requiring women were more likely to undergo cesarean delivery for first-stage arrest and less likely to undergo cesarean delivery for nonreassuring fetal status. Targeted sequencing of the oxytocin receptor gene in the total cohort (n = 187) revealed 30 distinct coding variants: 17 nonsynonymous, 11 synonymous, and 2 small structural variants. One novel variant (A243T) was found in both the low- and high-dose-requiring groups. Three novel variants (Y106H, A240_A249del, and P197delfs*206) resulting in an amino acid substitution, loss of 9 amino acids, and a frameshift stop mutation, respectively, were identified only in low-dose

  15. Neutron spectra and dose equivalents calculated in tissue for high-energy radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kry, Stephen F.; Howell, Rebecca M.; Salehpour, Mohammad; Followill, David S. [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States)

    2009-04-15

    Neutrons are by-products of high-energy radiation therapy and a source of dose to normal tissues. Thus, the presence of neutrons increases a patient's risk of radiation-induced secondary cancer. Although neutrons have been thoroughly studied in air, little research has been focused on neutrons at depths in the patient where radiosensitive structures may exist, resulting in wide variations in neutron dose equivalents between studies. In this study, we characterized properties of neutrons produced during high-energy radiation therapy as a function of their depth in tissue and for different field sizes and different source-to-surface distances (SSD). We used a previously developed Monte Carlo model of an accelerator operated at 18 MV to calculate the neutron fluences, energy spectra, quality factors, and dose equivalents in air and in tissue at depths ranging from 0.1 to 25 cm. In conjunction with the sharply decreasing dose equivalent with increased depth in tissue, the authors found that the neutron energy spectrum changed drastically as a function of depth in tissue. The neutron fluence decreased gradually as the depth increased, while the average neutron energy decreased sharply with increasing depth until a depth of approximately 7.5 cm in tissue, after which it remained nearly constant. There was minimal variation in the quality factor as a function of depth. At a given depth in tissue, the neutron dose equivalent increased slightly with increasing field size and decreasing SSD; however, the percentage depth-dose equivalent curve remained constant outside the primary photon field. Because the neutron dose equivalent, fluence, and energy spectrum changed substantially with depth in tissue, we concluded that when the neutron dose equivalent is being determined at a depth within a patient, the spectrum and quality factor used should be appropriate for depth rather than for in-air conditions. Alternately, an appropriate percent depth-dose equivalent curve

  16. Application of a pelvic phantom in brachytherapy dosimetry for high-dose-rate (HDR) 192Ir source based on Monte Carlo simulations

    Science.gov (United States)

    Ahn, Woo Sang; Choi, Wonsik; Shin, Seong Soo; Jung, Jinhong

    2014-08-01

    In this study, we evaluate how the radial dose function is influenced by the source position as well as the phantom size and shape. A pelvic water phantom similar to the pelvic shape of a human body was designed by averaging dimensions obtained from computed tomography (CT) images of patients treated with brachytherapy for cervical cancer. Furthermore, for the study of the effects of source position on the dose distribution, the position of the source in the water phantom was determined by using the center of mass of the gross target volume (GTV) in the CT images. To obtain the dosimetric parameter of a high-dose-rate (HDR) 192Ir source, we performed Monte Carlo simulations by using the Monte Carlo n-particle extended code (MCNPX). The radial dose functions obtained using the pelvic water phantom were compared with those of spherical phantom with different sizes, including the Monte Carlo (MC) results of Williamson and Li. Differences between the radial dose functions from this study and the data in the literature increased with the radial distances. The largest differences appeared for spherical phantom with the smallest size. In contrast to the published MC results, the radial dose function of the pelvic water phantom significantly decreased with radial distance in the vertical direction because full scattering was not possible. When the source was located in posterior position 2 cm from the center in the pelvic water phantom, the differences between the radial dose functions rapidly decreased with the radial distance in the lower vertical direction. If the International Commission on Radiation Units and Measurements bladder and rectum points are considered, doses to these reference points could be underestimated by up to 1%-2% at a distance of 3 to 6 cm. Our simulation results provide a valid clinical reference data and can used to improve the accuracy of the doses delivered during brachytherapy applied to patients with cervical cancer.

  17. A Broad Range of Dose Optima Achieve High-level, Long-term Gene Expression After Hydrodynamic Delivery of Sleeping Beauty Transposons Using Hyperactive SB100x Transposase

    Science.gov (United States)

    Podetz-Pedersen, Kelly M; Olson, Erik R; Somia, Nikunj V; Russell, Stephen J; McIvor, R Scott

    2016-01-01

    The Sleeping Beauty (SB) transposon system has been shown to enable long-term gene expression by integrating new sequences into host cell chromosomes. We found that the recently reported SB100x hyperactive transposase conferred a surprisingly high level of long-term expression after hydrodynamic delivery of luciferase-encoding reporter transposons in the mouse. We conducted dose-ranging studies to determine the effect of varying the amount of SB100x transposase-encoding plasmid (pCMV-SB100x) at a set dose of luciferase transposon and of varying the amount of transposon-encoding DNA at a set dose of pCMV-SB100x in hydrodynamically injected mice. Animals were immunosuppressed using cyclophosphamide in order to prevent an antiluciferase immune response. At a set dose of transposon DNA (25 µg), we observed a broad range of pCMV-SB100x doses (0.1–2.5 µg) conferring optimal levels of long-term expression (>1011 photons/second/cm2). At a fixed dose of 0.5 μg of pCMV-SB100x, maximal long-term luciferase expression (>1010 photons/second/cm2) was achieved at a transposon dose of 5–125 μg. We also found that in the linear range of transposon doses (100 ng), co-delivering the CMV-SB100x sequence on the same plasmid was less effective in achieving long-term expression than delivery on separate plasmids. These results show marked flexibility in the doses of SB transposon plus pCMV-SB100x that achieve maximal SB-mediated gene transfer efficiency and long-term gene expression after hydrodynamic DNA delivery to mouse liver. PMID:26784638

  18. 3D-printed applicators for high dose rate brachytherapy: Dosimetric assessment at different infill percentage.

    Science.gov (United States)

    Ricotti, Rosalinda; Vavassori, Andrea; Bazani, Alessia; Ciardo, Delia; Pansini, Floriana; Spoto, Ruggero; Sammarco, Vittorio; Cattani, Federica; Baroni, Guido; Orecchia, Roberto; Jereczek-Fossa, Barbara Alicja

    2016-12-01

    Dosimetric assessment of high dose rate (HDR) brachytherapy applicators, printed in 3D with acrylonitrile butadiene styrene (ABS) at different infill percentage. A low-cost, desktop, 3D printer (Hamlet 3DX100, Hamlet, Dublin, IE) was used for manufacturing simple HDR applicators, reproducing typical geometries in brachytherapy: cylindrical (common in vaginal treatment) and flat configurations (generally used to treat superficial lesions). Printer accuracy was investigated through physical measurements. The dosimetric consequences of varying the applicator's density by tuning the printing infill percentage were analysed experimentally by measuring depth dose profiles and superficial dose distribution with Gafchromic EBT3 films (International Specialty Products, Wayne, NJ). Dose distributions were compared to those obtained with a commercial superficial applicator. Measured printing accuracy was within 0.5mm. Dose attenuation was not sensitive to the density of the material. Surface dose distribution comparison of the 3D printed flat applicators with respect to the commercial superficial applicator showed an overall passing rate greater than 94% for gamma analysis with 3% dose difference criteria, 3mm distance-to-agreement criteria and 10% dose threshold. Low-cost 3D printers are a promising solution for the customization of the HDR brachytherapy applicators. However, further assessment of 3D printing techniques and regulatory materials approval are required for clinical application. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. Milk residues and performance of lactating dairy cows administered high doses of monensin.

    Science.gov (United States)

    Bagg, Randal; Vessie, Gordon H; Dick, C Paul; Duffield, Todd; Wilson, Jeff B; Aramini, Jeff J

    2005-07-01

    Milk residues and performance were evaluated in lactating cows that were fed up to 10 times the recommended dose of monensin. Following an acclimatization period of 14 d, during which cows were fed a standard lactating cow total mixed ration containing 24 ppm monensin, 18 lactating Holstein dairy cows were grouped according to the level of feed intake and then randomly assigned within each group to 1 of 3 challenge rations delivering 72, 144, and 240 ppm monensin. Outcome measurements included individual cow daily feed intakes, daily milk production, body weights, and monensin residues in composite milk samples from each cow. There were no detectable monensin residues (cows receiving a dose of 72 ppm monensin exhibited up to a 20% reduction in dry matter intake, and a 5% to 15% drop in milk production from the pre-challenge period. Cows receiving doses of 144 and 240 ppm monensin exhibited rapid decreases in feed intake of up to 50% by the 2nd d and milk production losses of up to 20% and 30%, respectively, within 4 d. Lactating cows receiving up to 4865 mg monensin per day had no detectable monensin residues (dairy cattle receiving monensin at recommended levels are safe for human consumption.

  20. Assessment of The Dose-Response Relationship of Radiation-Induced Bystander Effect in Two Cell Lines Exposed to High Doses of Ionizing Radiation (6 and 8 Gy).

    Science.gov (United States)

    Bahreyni Toossi, Mohammad Taghi; Khademi, Sara; Azimian, Hosein; Mohebbi, Shokoufeh; Soleymanifard, Shokouhozaman

    2017-10-01

    The dose-response relationship of radiation-induced bystander effect (RIBE) is controversial at high dose levels. The aim of the present study is to assess RIBE at high dose levels by examination of different endpoints. This experimental study used the medium transfer technique to induce RIBE. The cells were divided into two main groups: QU-DB cells which received medium from autologous irradiated cells and MRC5 cells which received medium from irradiated QU-DB cells. Colony, MTT, and micronucleus assays were performed to quantify bystander responses. The medium was diluted and transferred to bystander cells to investigate whether medium dilution could revive the RIBE response that disappeared at a high dose. The RIBE level in QU-DB bystander cells increased in the dose range of 0.5 to 4 Gy, but decreased at 6 and 8 Gy. The Micronucleated cells per 1000 binucleated cells (MNBN) frequency of QU-DB bystander cells which received the most diluted medium from 6 and 8 Gy QU-DB irradiated cells reached the maximum level compared to the MNBN frequency of the cells that received complete medium (Pbystander cells. This finding confirmed that a negative feedback mechanism was responsible for the decrease in RIBE response at high doses. Decrease of RIBE at high doses might be used to predict that in radiosurgery, brachytherapy and grid therapy, in which high dose per fraction is applied, normal tissue damage owing to RIBE may decrease.

  1. SU-E-CAMPUS-I-04: Automatic Skin-Dose Mapping for An Angiographic System with a Region-Of-Interest, High-Resolution Detector

    Energy Technology Data Exchange (ETDEWEB)

    Vijayan, S; Rana, V [Department of Physiology and Biophysics, Toshiba Stroke and Vascular Research Center (United States); Setlur Nagesh, S [Toshiba Stroke and Vascular Research Center (United States); Ionita, C [Department of Biomedical Engineering, University at Buffalo (State University of New York), Buffalo, NY (United States); Rudin, S [Department of Radiology, Department of Physiology and Biophysics, Toshiba Stroke and Vascular Research Center, Department of Biomedical Engineering, University at Buffalo (State University of New York), Buffalo, NY (United States); Bednarek, D [Department of Radiology, Department of Physiology and Biophysics, Toshiba Stroke and Vascular Research Center (United States)

    2014-06-15

    Purpose: Our real-time skin dose tracking system (DTS) has been upgraded to monitor dose for the micro-angiographic fluoroscope (MAF), a high-resolution, small field-of-view x-ray detector. Methods: The MAF has been mounted on a changer on a clinical C-Arm gantry so it can be used interchangeably with the standard flat-panel detector (FPD) during neuro-interventional procedures when high resolution is needed in a region-of-interest. To monitor patient skin dose when using the MAF, our DTS has been modified to automatically account for the change in scatter for the very small MAF FOV and to provide separated dose distributions for each detector. The DTS is able to provide a color-coded mapping of the cumulative skin dose on a 3D graphic model of the patient. To determine the correct entrance skin exposure to be applied by the DTS, a correction factor was determined by measuring the exposure at the entrance surface of a skull phantom with an ionization chamber as a function of entrance beam size for various beam filters and kVps. Entrance exposure measurements included primary radiation, patient backscatter and table forward scatter. To allow separation of the dose from each detector, a parameter log is kept that allows a replay of the procedure exposure events and recalculation of the dose components.The graphic display can then be constructed showing the dose distribution from the MAF and FPD separately or together. Results: The DTS is able to provide separate displays of dose for the MAF and FPD with field-size specific scatter corrections. These measured corrections change from about 49% down to 10% when changing from the FPD to the MAF. Conclusion: The upgraded DTS allows identification of the patient skin dose delivered when using each detector in order to achieve improved dose management as well as to facilitate peak skin-dose reduction through dose spreading. Research supported in part by Toshiba Medical Systems Corporation and NIH Grants R43FD0158401, R44FD

  2. Impact of therapeutic and high doses of florfenicol on kidney and liver functional indicators in goat

    Directory of Open Access Journals (Sweden)

    Jan Muhammad Shah

    2016-10-01

    Full Text Available Aim: The aim of this study was to evaluate the impact of therapeutic and high doses of florfenicol on kidney and liver functional indicators in goat species. Materials and Methods: Six mature, healthy goats (combine breed and sex with average weight 25 kg were selected for this study. The therapeutic (20 mg/kg b.w. and high doses (40 and 60 mg of florfenicol were administered for 3 days with 24 h interval. Blood samples were collected at 0, 24, 48, 72, 96, and 120 h following the each administered dose. Results: The results showed that the therapeutic dose of florfenicol produced nonsignificant effect on serum urea, creatinine, total protein (TP, alkaline phosphatase (ALP, gamma-glutamyl transferase (GGT and bilirubin on all timings, and increased (p<0.05 the serum glutamic oxaloacetic transaminase (SGOT and serum glutamate-pyruvate transaminase (SGPT levels for 48 h. Whereas the high doses of florfenicol (40 and 60 mg significantly altered the kidney and liver functional indicators in the blood. In contrast with control, the serum urea level was (p<0.01 increased at all timing points. Creatinine values were altered (p<0.01, <0.05 in increasing manner from 24 to 96 h. The high dose of 40 mg decreased the TP (p<0.05 for 72 h and 60 mg persisted same effect (p<0.01 up to 120 h. The indices of ALP, GGT, SGOT, and SGPT were raised (p<0.01, <0.05 at all timings. The bilirubin indexes also (p<0.05 elevated from 48 to 72. Conclusion: It was concluded that the high doses of florfenicol produced reversible dose-dependent effects on functional indicators of kidney and liver such as urea, creatinine, TP, ALP, SGOT, SGPT, GGT, and bilirubin.

  3. Feasibility of safe ultra-high (EQD{sub 2}>100 Gy) dose escalation on dominant intra-prostatic lesions (DILs) by Helical Tomotheraphy

    Energy Technology Data Exchange (ETDEWEB)

    Maggio, Angelo; Fiorino, Claudio; Mangili, Paola; Cattaneo, Giovanni Mauro; Del Maschio, Alessandro; Calandrino, Riccardo (Medical Physics, San Raffaele Scientific Inst., Milano (Italy)), e-mail: fiorino.claudio@hsr.it; Muzio, Nadia Di; Cozzarini, Cesare (Radiotherapy, San Raffaele Scientific Inst., Milano (Italy)); Cobelli, Francesco de (Radiology, San Raffaele Scientific Inst., Milano (Italy)); Rancati, Tiziana (Programma Prostata, National Inst. of Cancer, Milano (Italy))

    2011-01-15

    Purpose. To verify the possibility of using Helical Tomotherapy to safely escalate dose to single or multiple highly radioresistant dominant intra-prostatic lesions (DILs) as assessed by functional magnetic resonance imaging (MRI). Material. In seven intermediate/high risk patients, T2WI, T1WI and DWI MRI imaging showed evidence of one DIL in four patients and two DILs in three patients in the peripheral zone of the prostate. The planning strategy was to deliver median doses of 80, 90, 100 and 120 Gy to PTVDIL while delivering 71.4 Gy/28 fractions (EQD{sub 2}=75 Gy) to the remaining portion of PTV. A higher priority was assigned to rectal constraints relative to DIL coverage. Rectal NTCP calculations were performed using the most recently available model data. Results. The median dose to DIL could safely be escalated to at least 100 Gy (EQD{sub 2,{alpha}/{beta}=10}=113 Gy) without violating safe constraints for the organs at risk. Typical rectal NTCP values were around or below 1-3% for G3 toxicity and 5-7% for G2-G3 toxicity. For the 100 Gy DIL dose boost strategy, mean D95% of DIL and PTVDIL were 98.8 Gy and 86.7 Gy, respectively. The constraints for bladder, urethra and femoral heads were always respected. Conclusions. IGRT by Helical Tomotherapy may permit the safe escalation of EQD{sub 2,{alpha}/{eta}=10} to at least 113 Gy to DILs without significantly increasing rectal NTCP compared to plans without dose escalation. A Phase I-II clinical study is warranted

  4. Tandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer

    OpenAIRE

    2015-01-01

    Purpose In high-dose-rate (HDR) brachytherapy (BT), the source dwell times and dwell positions are essential treatment planning parameters. An optimal choice of these factors is fundamental to obtain the desired target coverage with the lowest achievable dose to the organs at risk (OARs). This study evaluates relevant dose parameters in cervix brachytherapy in order to assess existing tandem-ring dwell time ratio used at the first HDR BT center in Nigeria, and compare it with an alternative s...

  5. High doses of pseudoephedrine hydrochloride accelerate onset of CNS oxygen toxicity seizures in unanesthetized rats.

    Science.gov (United States)

    Pilla, R; Held, H E; Landon, C S; Dean, J B

    2013-08-29

    Pseudoephedrine (PSE) salts (hydrochloride and sulfate) are commonly used as nasal and paranasal decongestants by scuba divers. Anecdotal reports from the Divers Alert Network suggest that taking PSE prior to diving while breathing pure O₂ increases the risk for CNS oxygen toxicity (CNS-OT), which manifests as seizures. We hypothesized that high doses of PSE reduce the latency time to seizure (LS) in unanesthetized rats breathing 5 atmospheres absolute (ATA) of hyperbaric oxygen. Sixty-three male rats were implanted with radio-transmitters that recorded electroencephalogram activity and body temperature. After ≥7-day recovery, and 2 h before "diving", each rat was administered either saline solution (control) or PSE hydrochloride intragastrically at the following doses (mg PSE/kg): 0, 40, 80, 100, 120, 160, and 320. Rats breathed pure O₂ and were dived to 5ATA until the onset of behavioral seizures coincident with neurological seizures. LS was the time elapsed between reaching 5ATA and exhibiting seizures. We observed a significant dose-dependent decrease in the LS at doses of 100-320 mg/kg, whereas no significant differences in LS from control value were observed at doses ≤80 mg/kg. Our findings showed that high doses of PSE accelerate the onset of CNS-OT seizures in unanesthetized rats breathing 5ATA of poikilocapnic hyperoxia. Extrapolating our findings to humans, we conclude that the recommended daily dose of PSE should not be abused prior to diving with oxygen-enriched gas mixes or pure O₂.

  6. Continual Low-Dose Infusion of Sulfamidase Is Superior to Intermittent High-Dose Delivery in Ameliorating Neuropathology in the MPS IIIA Mouse Brain.

    Science.gov (United States)

    Beard, Helen; Hassiotis, Sofia; Luck, Amanda J; Rozaklis, Tina; Hopwood, John J; Hemsley, Kim M

    2016-01-01

    Mucopolysaccharidosis IIIA (MPS IIIA) is a neurodegenerative lysosomal storage disorder characterised by progressive loss of learned skills, sleep disturbance and behavioural problems. Reduced activity of lysosomal sulfamidase results in accumulation of heparan sulfate and secondary storage of glycolipids in the brain. Intra-cisternal sulfamidase infusions reduce disease-related neuropathology; however, repeated injections may subject patients to the risk of infection and tissue damage so alternative approaches are required. We undertook a proof-of-principle study comparing the ability of slow/continual or repeat/bolus infusion to ameliorate neuropathology in MPS IIIA mouse brain. Six-week-old MPS IIIA mice were implanted with subcutaneously located mini-osmotic pumps filled with recombinant human sulfamidase (rhSGSH) or vehicle, connected to lateral ventricle-directed cannulae. Pumps were replaced at 8 weeks of age. Additional MPS IIIA mice received intra-cisternal bolus infusions of the same amount of rhSGSH (or vehicle), at 6 and 8 weeks of age. Unaffected mice received vehicle via each strategy. All mice were euthanised at 10 weeks of age and the brain was harvested to assess the effect of treatment on neuropathology. Mice receiving pump-delivered rhSGSH exhibited highly significant reductions in lysosomal storage markers (lysosomal integral membrane protein-2, GM3 ganglioside and filipin-positive lipids) and neuroinflammation (isolectin B4-positive microglia, glial fibrillary acidic protein-positive astroglia). MPS IIIA mice receiving rhSGSH via bolus infusion displayed reductions in these markers, but the effectiveness of the strategy was inferior to that seen with slow/pump-based delivery. Continual low-dose infusion may therefore be a more effective strategy for enzyme delivery in MPS IIIA.

  7. Image-guided high-dose-rate brachytherapy in inoperable endometrial cancer

    Science.gov (United States)

    Petsuksiri, J; Chansilpa, Y; Hoskin, P J

    2014-01-01

    Inoperable endometrial cancer may be treated with curative aim using radical radiotherapy alone. The radiation techniques are external beam radiotherapy (EBRT) alone, EBRT plus brachytherapy and brachytherapy alone. Recently, high-dose-rate brachytherapy has been used instead of low-dose-rate brachytherapy. Image-guided brachytherapy enables sufficient coverage of tumour and reduction of dose to the organs at risk, thus increasing the therapeutic ratio of treatment. Local control rates with three-dimensional brachytherapy appear better than with conventional techniques (about 90–100% and 70–90%, respectively). PMID:24807067

  8. Dose equivalent measurements in mixed and time varying radiation fields around high-energy accelerators

    CERN Document Server

    Mayer, S

    2003-01-01

    Measurements of ambient dose equivalent in stray radiation fields behind the shielding of high-energy accelerators are a challenging task. Several radiation components (photons, neutrons, charged particles, muons, etc.), spanning a wide range of energies, contribute to the total dose equivalent. The radiation fields are produced by beam losses interacting with structural material during the acceleration or at the ejection to experimental areas or other accelerators. The particle beam is usually not continuous but separated in "bunches" or pulses, which further complicates dose measurements at high-energy accelerators. An ideal dosimeter for operational radiation protection should measure dose equivalent for any composition of radiation components in the entire energy range even when the field is strongly pulsed. The objective of this work was to find out if an ionisation chamber operated as a "recombination chamber" and a TEPC instrument using the variance-covariance method ("Sievert Instrument") are capable ...

  9. Dose equivalent measurements in mixed and time varying radiation fields around high-energy accelerators

    CERN Document Server

    Mayer, S

    2003-01-01

    Measurements of ambient dose equivalent in stray radiation fields behind the shielding of high-energy accelerators are a challenging task. Several radiation components (photons, neutrons, charged particles, muons, etc.), spanning a wide range of energies, contribute to the total dose equivalent. The radiation fields are produced by beam losses interacting with structural material during the acceleration or at the ejection to experimental areas or other accelerators. The particle beam is usually not continuous but separated in "bunches" or pulses, which further complicates dose measurements at high-energy accelerators. An ideal dosimeter for operational radiation protection should measure dose equivalent for any composition of radiation components in the entire energy range even when the field is strongly pulsed. The objective of this work was to find out if an ionisation chamber operated as a "recombination chamber" and a TEPC instrument using the variance-covariance method ("Sievert Instrument") are capable ...

  10. Cervical Gross Tumor Volume Dose Predicts Local Control Using Magnetic Resonance Imaging/Diffusion-Weighted Imaging—Guided High-Dose-Rate and Positron Emission Tomography/Computed Tomography—Guided Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Dyk, Pawel; Jiang, Naomi; Sun, Baozhou; DeWees, Todd A. [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Fowler, Kathryn J.; Narra, Vamsi [Department of Diagnostic Radiology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Garcia-Ramirez, Jose L.; Schwarz, Julie K. [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Grigsby, Perry W., E-mail: pgrigsby@wustl.edu [Department of Radiation Oncology, Washington University School of Medicine, St Louis, Missouri (United States); Division of Nuclear Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Division of Gynecologic Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Missouri (United States); Alvin J. Siteman Cancer Center, Washington University School of Medicine, St Louis, Missouri (United States)

    2014-11-15

    Purpose: Magnetic resonance imaging/diffusion weighted-imaging (MRI/DWI)-guided high-dose-rate (HDR) brachytherapy and {sup 18}F-fluorodeoxyglucose (FDG) — positron emission tomography/computed tomography (PET/CT)-guided intensity modulated radiation therapy (IMRT) for the definitive treatment of cervical cancer is a novel treatment technique. The purpose of this study was to report our analysis of dose-volume parameters predicting gross tumor volume (GTV) control. Methods and Materials: We analyzed the records of 134 patients with International Federation of Gynecology and Obstetrics stages IB1-IVB cervical cancer treated with combined MRI-guided HDR and IMRT from July 2009 to July 2011. IMRT was targeted to the metabolic tumor volume and lymph nodes by use of FDG-PET/CT simulation. The GTV for each HDR fraction was delineated by use of T2-weighted or apparent diffusion coefficient maps from diffusion-weighted sequences. The D100, D90, and Dmean delivered to the GTV from HDR and IMRT were summed to EQD2. Results: One hundred twenty-five patients received all irradiation treatment as planned, and 9 did not complete treatment. All 134 patients are included in this analysis. Treatment failure in the cervix occurred in 24 patients (18.0%). Patients with cervix failures had a lower D100, D90, and Dmean than those who did not experience failure in the cervix. The respective doses to the GTV were 41, 58, and 136 Gy for failures compared with 67, 99, and 236 Gy for those who did not experience failure (P<.001). Probit analysis estimated the minimum D100, D90, and Dmean doses required for ≥90% local control to be 69, 98, and 260 Gy (P<.001). Conclusions: Total dose delivered to the GTV from combined MRI-guided HDR and PET/CT-guided IMRT is highly correlated with local tumor control. The findings can be directly applied in the clinic for dose adaptation to maximize local control.

  11. On LiF:Mg,Cu,P and LiF:Mg,Ti phosphors high & ultra-high dose features

    CERN Document Server

    Obryk, Barbara; de Barros, Vinicius S; Guzzo, Pedro L; Bilski, Paweł

    2013-01-01

    LiF:Mg,Ti and LiF:Mg,Cu,P are well known thermoluminescence (TL) dosimetry materials since many years. A few years ago their properties seemed well known and it was widely believed that they are not suitable for the measurement of doses above the saturation level of the TL signal, which for both materials occur at about 1 kGy. The high-dose high-temperature TL emission of LiF:Mg,Cu,P observed at the IFJ in 2006, which above 30 kGy takes the form of the so-called TL peak B, opened the way to use this material for measuring the dose in the high and ultra-high range, in particular for the monitoring of ionizing radiation around the essential electronic elements of high-energy accelerators, also fission and fusion facilities, as well as for emergency dosimetry. This discovery initiated studies of high and ultra-high dose characteristics of both of these phosphors, which turned out to be significantly different in many aspects. These studies not only strive to refine the method for measuring high doses based on th...

  12. Internet-delivered cognitive behavioural therapy for adults with mild to moderate depression and high cardiovascular disease risks: a randomised attention-controlled trial.

    Science.gov (United States)

    Glozier, Nicholas; Christensen, Helen; Naismith, Sharon; Cockayne, Nicole; Donkin, Liesje; Neal, Bruce; Mackinnon, Andrew; Hickie, Ian

    2013-01-01

    Mild to moderate depression is common in those with cardiovascular disease and undertreated. We aimed to evaluate the effectiveness of internet-delivered Cognitive Behaviour Therapy (iCBT) on depressive symptom severity and adherence to medical advice and lifestyle interventions in adults with mild to moderate depression and high cardiovascular disease (CVD) risks. Randomised double-blind, 12 week attention-controlled trial comparing an iCBT programme (E-couch) with an internet-delivered attention control health information package (HealthWatch, n = 282). The primary outcome was depression symptom level on the nine-item Patient Health Questionnaire (PHQ-9) (trial registration: ACTRN12610000085077). 487/562 (88%) participants completed the endpoint assessment. 383/562 (70%) were currently treated for cardiovascular disease and 314/562 (56%) had at least one other comorbid condition. In ITT analysis of 562 participants iCBT produced a greater decline in the mean PHQ-9 score compared to the attention control of 1.06 (95% CI: 0.23-1.89) points, with differences between the two arms increasing over the intervention period (time by treatment effect interaction p = .012). There were also larger improvements in adherence (2.16 points; 95% CI: 0.33-3.99), reductions in anxiety (0.96 points; 95% CI: 0.19-1.73), and a greater proportion engaging in beneficial physical activity (Odds Ratio 1.91, 95%CI: 1.01-3.61) in the iCBT participants but no effect upon disability, or walking time/day. There were no withdrawals due to study related adverse events. In people with mild to moderate depression and high levels of CVD risk factors, a freely accessible iCBT programme (http://www.ecouch.anu.edu.au) produced a small, but robust, improvement in depressive symptoms, adherence and some health behaviours. Australian and New Zealand Clinical Trials Registry ACTRN12610000085077.

  13. Does High-Dose Antimicrobial Chemotherapy Prevent the Evolution of Resistance?

    Science.gov (United States)

    Day, Troy; Read, Andrew F.

    2016-01-01

    High-dose chemotherapy has long been advocated as a means of controlling drug resistance in infectious diseases but recent empirical studies have begun to challenge this view. We develop a very general framework for modeling and understanding resistance emergence based on principles from evolutionary biology. We use this framework to show how high-dose chemotherapy engenders opposing evolutionary processes involving the mutational input of resistant strains and their release from ecological competition. Whether such therapy provides the best approach for controlling resistance therefore depends on the relative strengths of these processes. These opposing processes typically lead to a unimodal relationship between drug pressure and resistance emergence. As a result, the optimal drug dose lies at either end of the therapeutic window of clinically acceptable concentrations. We illustrate our findings with a simple model that shows how a seemingly minor change in parameter values can alter the outcome from one where high-dose chemotherapy is optimal to one where using the smallest clinically effective dose is best. A review of the available empirical evidence provides broad support for these general conclusions. Our analysis opens up treatment options not currently considered as resistance management strategies, and it also simplifies the experiments required to determine the drug doses which best retard resistance emergence in patients. PMID:26820986

  14. The response of various neutron dose meters considering the application at a high energy particle accelerator

    CERN Document Server

    Gutermuth, F; Fehrenbacher, G; Festag, J G

    2003-01-01

    The applicability of several neutron detectors for dose measurements at a neutron field typical for high energy particle accelerators is investigated. The response of four commercially available active neutron dose meters and two passive detectors to neutrons from a sup 2 sup 4 sup 1 Am-Be(alpha,n) source and to neutrons at the CERN EU high energy reference field was determined experimentally and simulated using the Monte-Carlo code FLUKA. Fluence response functions and dose responses for the different detectors were calculated in the energy range between 1 keV and 10 GeV. The results show that the dose response to the high energy neutron field at CERN of the conventional rem-counters is lower by a factor of 2 to 2.5 if compared to the dose response to a sup 2 sup 4 sup 1 Am-Be(alpha,n) neutron source. The rem-counters exhibiting an additional layer of lead inside the moderating structure showed dose readings which differ only up to 25%. A thermoluminescent based neutron detector was tested for comparison. Th...

  15. Does High-Dose Antimicrobial Chemotherapy Prevent the Evolution of Resistance?

    Science.gov (United States)

    Day, Troy; Read, Andrew F

    2016-01-01

    High-dose chemotherapy has long been advocated as a means of controlling drug resistance in infectious diseases but recent empirical studies have begun to challenge this view. We develop a very general framework for modeling and understanding resistance emergence based on principles from evolutionary biology. We use this framework to show how high-dose chemotherapy engenders opposing evolutionary processes involving the mutational input of resistant strains and their release from ecological competition. Whether such therapy provides the best approach for controlling resistance therefore depends on the relative strengths of these processes. These opposing processes typically lead to a unimodal relationship between drug pressure and resistance emergence. As a result, the optimal drug dose lies at either end of the therapeutic window of clinically acceptable concentrations. We illustrate our findings with a simple model that shows how a seemingly minor change in parameter values can alter the outcome from one where high-dose chemotherapy is optimal to one where using the smallest clinically effective dose is best. A review of the available empirical evidence provides broad support for these general conclusions. Our analysis opens up treatment options not currently considered as resistance management strategies, and it also simplifies the experiments required to determine the drug doses which best retard resistance emergence in patients.

  16. Efeitos das isoflavonas em altas doses sobre o útero da rata Effects of high-dose isoflavones on rat uterus

    Directory of Open Access Journals (Sweden)

    Adriana Aparecida Ferraz Carbonel

    2011-10-01

    Full Text Available OBJETIVO: Avaliar o efeito de altas doses de isoflavonas no útero de ratas adultas castradas. MÉTODOS: Ratas virgens ovariectomizadas (n = 40 foram tratadas por 30 dias consecutivos com veículo (GCtrl ou genisteína nas concentrações 42 (GES42, 125 (GES125 e 250 (GES250 µg/g de peso corporal ao dia. O extrato de soja e o veículo (propilenoglicol foram administrados por gavagem. Ao final do experimento, foi realizada dosagem sérica de 17 β-estradiol e progesterona, avaliou-se o peso dos animais e dos úteros e foi feito exame colpocitológico. Fragmentos do terço médio dos cornos uterinos foram fixados em formol a 10% e processados para inclusão em parafina para estudo histológico. Cortes de 5 µm de espessura foram corados pelo HE e destinados a estudo em microscopia de luz. Analisou-se a histomorfologia do endométrio, área endometrial, número e área ocupada pelas glândulas, assim como a concentração de eosinófilos presentes na lâmina própria. Os dados numéricos obtidos foram submetidos à análise de variância complementada pelo teste de Tukey-Kramer (p GES125 do que nos outros grupos (GES250 > GES125 > GES42 = GCtrl; p OBJECTIVE: To evaluate the effects of high-dose isoflavones on the uterus of castrated adult rats. METHODS: Adult, ovariectomized virgin rats (n = 40 were treated by gavage during 30 consecutive days with vehicle (propylene glycol, group GCtrl or different doses of genistein: 42 (group GES42, 125 (GES125, or 250 (GES250 µg/g body weight per day. Animals were killed, weighed, vaginal and uterine samples were taken for cytologic evaluation, and serum levels of 17 β-estradiol and progesterone were determined. The middle third of the uterine horns was dissected, fixed in 10% formaldehyde and processed for paraffin inclusion; 5-µm thick sections were obtained and stained with HE for further histological study under light microscopy. The endometrial morphology and area, number and area of glands, and number

  17. Application of TL dosemeters for dose distribution measurements at high temperatures in nuclear reactors.

    Science.gov (United States)

    Osvay, M; Deme, S

    2006-01-01

    Al2O3:Mg,Y ceramic thermoluminescence dosemeters were developed at the Institute of Isotopes for high dose applications at room temperatures. The glow curve of Al2O3:Mg,Y exhibits two peaks--one at 250 degrees C (I) and another peak at approximately 400 degrees C (II). In order to extend the application of these dosemeters to high temperatures, the effect of irradiation temperature was investigated using temperature controlled heating system during high dose irradiation at various temperatures (20-100 degrees C). The new calibration and measuring method has been successfully applied for dose mapping within the hermetic zone of the Paks Nuclear Power Plant even at high temperature parts of blocks.

  18. The neutron dose equivalent around high energy medical electron linear accelerators

    Directory of Open Access Journals (Sweden)

    Poje Marina

    2014-01-01

    Full Text Available The measurement of neutron dose equivalent was made in four dual energy linear accelerator rooms. Two of the rooms were reconstructed after decommissioning of 60Co units, so the main limitation was the space. The measurements were performed by a nuclear track etched detectors LR-115 associated with the converter (radiator that consist of 10B and with the active neutron detector Thermo BIOREM FHT 742. The detectors were set at several locations to evaluate the neutron ambient dose equivalent and/or neutron dose rate to which medical personnel could be exposed. Also, the neutron dose dependence on collimator aperture was analyzed. The obtained neutron dose rates outside the accelerator rooms were several times smaller than the neutron dose rates inside the accelerator rooms. Nevertheless, the measured neutron dose equivalent was not negligible from the aspect of the personal dosimetry with almost 2 mSv a year per person in the areas occupied by staff (conservative estimation. In rooms with 15 MV accelerators, the neutron exposure to the personnel was significantly lower than in the rooms having 18 MV accelerators installed. It was even more pronounced in the room reconstructed after the 60Co decommissioning. This study confirms that shielding from the neutron radiation should be considered when building vaults for high energy linear accelerators, especially when the space constraints exist.

  19. High and Low Doses of Ionizing Radiation Induce Different Secretome Profiles in a Human Skin Model

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Qibin; Matzke, Melissa M.; Schepmoes, Athena A.; Moore, Ronald J.; Webb-Robertson, Bobbie-Jo M.; Hu, Zeping; Monroe, Matthew E.; Qian, Weijun; Smith, Richard D.; Morgan, William F.

    2014-03-18

    It is postulated that secreted soluble factors are important contributors of bystander effect and adaptive responses observed in low dose ionizing radiation. Using multidimensional liquid chromatography-mass spectrometry based proteomics, we quantified the changes of skin tissue secretome – the proteins secreted from a full thickness, reconstituted 3-dimensional skin tissue model 48 hr after exposure to 3, 10 and 200 cGy of X-rays. Overall, 135 proteins showed statistical significant difference between the sham (0 cGy) and any of the irradiated groups (3, 10 or 200 cGy) on the basis of Dunnett adjusted t-test; among these, 97 proteins showed a trend of downregulation and 9 proteins showed a trend of upregulation with increasing radiation dose. In addition, there were 21 and 8 proteins observed to have irregular trends with the 10 cGy irradiated group either having the highest or the lowest level among all three radiated doses. Moreover, two proteins, carboxypeptidase E and ubiquitin carboxyl-terminal hydrolase isozyme L1 were sensitive to ionizing radiation, but relatively independent of radiation dose. Conversely, proteasome activator complex subunit 2 protein appeared to be sensitive to the dose of radiation, as rapid upregulation of this protein was observed when radiation doses were increased from 3, to 10 or 200 cGy. These results suggest that different mechanisms of action exist at the secretome level for low and high doses of ionizing radiation.

  20. Amorphous and crystalline optical materials used as instruments for high gamma radiation doses estimations

    Energy Technology Data Exchange (ETDEWEB)

    Ioan, M-R., E-mail: razvan.ioan@nipne.ro

    2016-06-15

    Highlights: • The damage induced by gamma rays to optical materials was highlighted and quantified, using laser techniques. • Polarized light and the particularities of the laser light (monochromaticity, directionality and coherence) were used. • The correlation between the damage and the gamma rays absorbed dose was made. • The comparison between different types of optical materials and their dose related calibrations were made. • The uncertainty associated to the technique was determined. - Abstract: Nuclear radiation induce some changes to the structure of exposed materials. The main effect of ionizing radiation when interacting with optical materials is the occurrence of color centers, which are quantitatively proportional to the up-taken doses. In this paper, a relation between browning effect magnitude and dose values was found. Using this relation, the estimation of a gamma radiation dose can be done. By using two types of laser wavelengths (532 nm and 633 nm), the optical powers transmitted thru glass samples irradiated to different doses between 0 and 59.1 kGy, were measured and the associated optical browning densities were determined. The use of laser light gives the opportunity of using its particularities: monochromaticity, directionality and coherence. Polarized light was also used for enhancing measurements quality. These preliminary results bring the opportunity of using glasses as detectors for the estimation of the dose in a certain point in space and for certain energy, especially in particles accelerators experiments, where the occurred nuclear reactions are involving the presence of high gamma rays fields.

  1. High-dose insulin inhibits gap junction intercellular communication in vascular smooth muscle cells.

    Science.gov (United States)

    Bian, Ou; Zhang, Haishan; Guan, Qigang; Sun, Yingxian; Zeng, Dingyin

    2015-07-01

    Gap junction intercellular communication (GJIC) is important in mediating intercellular substance and signal transmission. Connexin (Cx)43 is a major component involved in GJIC in vascular tissue and its abnormal expression is closely associated with various vascular diseases. Insulin resistance is the central component of metabolic syndrome, and high doses of insulin can affect vascular function through multiple pathways, resulting in cardiovascular disease. However, the effects of insulin on GJIC function and connexin (Cx)43 expression in vascular smooth muscle cells (VSMCs) remain unclear. Following treatment of VSMCs with different doses of insulin, a fluorescence recovery after photobleaching (FRAP) assay was performed to evaluate GJIC function in treated VSMCs. The results showed that high‑dose insulin suppressed GJIC function. Western blot assays further demonstrated that high‑dose insulin induced the phosphorylation of Cx43 at s368 and downregulated the expression of Cx43. H2O2 release assays demonstrated that high‑dose insulin treatment significantly elevated the cellular H2O2 level. In addition, compared with cells treated with high‑dose insulin, pretreatment with catalase significantly restored the cellular GJIC function, decreased the phosphorylation level of Cx43 at s368, and enhanced Cx43 expression. In conclusion, these data indicate that high‑dose insulin inhibits cellular GJIC function through the oxidative stress‑activated signaling pathway. This phenomenon may also constitute a potential mechanism underlying the pathogenesis of insulin resistance and its complications.

  2. Comparative dosimetry of GammaMed Plus high-dose rate 192 Ir brachytherapy source

    Directory of Open Access Journals (Sweden)

    Patel N

    2010-01-01

    Full Text Available The comparative dosimetry of GammaMed (GM Plus high-dose rate brachytherapy source was performed by an experiment using 0.1-cc thimble ionization chamber and simulation-based study using EGSnrc code. In-water dose measurements were performed with 0.1-cc chamber to derive the radial dose function (r = 0.8 to 20.0 cm and anisotropy function (r = 5.0 cm with polar angle from 10° to 170°. The nonuniformity correction factor for 0.1-cc chamber was applied for in-water measurements at shorter distances from the source. The EGSnrc code was used to derive the dose rate constant (L, radial dose function g L (r and anisotropy function F(r, q of GM Plus source. The dosimetric data derived using EGSnrc code in our study were in very good agreement relative to published data for GM Plus source. The radial dose function up to 12 cm derived from measured dose using 0.1-cc chamber was in agreement within ±3% of data derived by the simulation study.

  3. High-dose vaginal maintenance metronidazole for recurrent bacterial vaginosis: a pilot study.

    Science.gov (United States)

    Aguin, Tina; Akins, Robert A; Sobel, Jack D

    2014-05-01

    The purpose of this study was to explore the benefit of high-dose intravaginal metronidazole as a maintenance therapy in reducing recurrence rates of bacterial vaginosis (BV). Eighteen women with a history of recurrent BV and symptomatic BV were treated with metronidazole 750 mg suppository intravaginally daily for 7 days. Those in remission by Amsel criteria received metronidazole 750 mg twice weekly for 3 months with further follow-up for 3 months. High-dose metronidazole intravaginally was associated with rare clinical recurrence during the period of use. After cessation of suppression therapy, recurrence was high.

  4. High dose zinc supplementation induces hippocampal zinc deficiency and memory impairment with inhibition of BDNF signaling.

    Directory of Open Access Journals (Sweden)

    Yang Yang

    Full Text Available Zinc ions highly concentrate in hippocampus and play a key role in modulating spatial learning and memory. At a time when dietary fortification and supplementation of zinc have increased the zinc consuming level especially in the youth, the toxicity of zinc overdose on brain function was underestimated. In the present study, weaning ICR mice were given water supplemented with 15 ppm Zn (low dose, 60 ppm Zn (high dose or normal lab water for 3 months, the behavior and brain zinc homeostasis were tested. Mice fed high dose of zinc showed hippocampus-dependent memory impairment. Unexpectedly, zinc deficiency, but not zinc overload was observed in hippocampus, especially in the mossy fiber-CA3 pyramid synapse. The expression levels of learning and memory related receptors and synaptic proteins such as NMDA-NR2A, NR2B, AMPA-GluR1, PSD-93 and PSD-95 were significantly decreased in hippocampus, with significant loss of dendritic spines. In keeping with these findings, high dose intake of zinc resulted in decreased hippocampal BDNF level and TrkB neurotrophic signaling. At last, increasing the brain zinc level directly by brain zinc injection induced BDNF expression, which was reversed by zinc chelating in vivo. These results indicate that zinc plays an important role in hippocampus-dependent learning and memory and BDNF expression, high dose supplementation of zinc induces specific zinc deficiency in hippocampus, which further impair learning and memory due to decreased availability of synaptic zinc and BDNF deficit.

  5. High dose zinc supplementation induces hippocampal zinc deficiency and memory impairment with inhibition of BDNF signaling.

    Science.gov (United States)

    Yang, Yang; Jing, Xiao-Peng; Zhang, Shou-Peng; Gu, Run-Xia; Tang, Fang-Xu; Wang, Xiu-Lian; Xiong, Yan; Qiu, Mei; Sun, Xu-Ying; Ke, Dan; Wang, Jian-Zhi; Liu, Rong

    2013-01-01

    Zinc ions highly concentrate in hippocampus and play a key role in modulating spatial learning and memory. At a time when dietary fortification and supplementation of zinc have increased the zinc consuming level especially in the youth, the toxicity of zinc overdose on brain function was underestimated. In the present study, weaning ICR mice were given water supplemented with 15 ppm Zn (low dose), 60 ppm Zn (high dose) or normal lab water for 3 months, the behavior and brain zinc homeostasis were tested. Mice fed high dose of zinc showed hippocampus-dependent memory impairment. Unexpectedly, zinc deficiency, but not zinc overload was observed in hippocampus, especially in the mossy fiber-CA3 pyramid synapse. The expression levels of learning and memory related receptors and synaptic proteins such as NMDA-NR2A, NR2B, AMPA-GluR1, PSD-93 and PSD-95 were significantly decreased in hippocampus, with significant loss of dendritic spines. In keeping with these findings, high dose intake of zinc resulted in decreased hippocampal BDNF level and TrkB neurotrophic signaling. At last, increasing the brain zinc level directly by brain zinc injection induced BDNF expression, which was reversed by zinc chelating in vivo. These results indicate that zinc plays an important role in hippocampus-dependent learning and memory and BDNF expression, high dose supplementation of zinc induces specific zinc deficiency in hippocampus, which further impair learning and memory due to decreased availability of synaptic zinc and BDNF deficit.

  6. Oxidative stress and innate immunity status in chickens exposed to high dose of ascorbic acid.

    Science.gov (United States)

    Berzina, Nadezhda; Markovs, Jurijs; Dizhbite, Tatiana; Apsite, Mirdza; Vasilyeva, Svetlana; Basova, Nataliya; Smirnova, Galina; Isajevs, Sergejs

    2013-10-01

    The effects of high dose ascorbic acid (10 000 mg·kg(-1) in the diet) and the transition metal on the presence of oxidative stress in the internal organs of growing chicks, as well as on the innate immune system status, were investigated. Supplementation with a high dose of ascorbic acid had pro-inflammatory effects on the intestinal mucosa, and lysozyme levels were decreased significantly in all organs studied. High-dose ascorbic acid caused an imbalance between prooxidative and antioxidative activities and was associated with the generation of semiquinone radicals. We observed that ascorbic acid increased iron and cadmium absorption. When a high dose of ascorbic acid was applied, elevated kidney and intestinal mucosa iron concentrations were observed. The amount of free malondialdehyde in the above organs has increased as well. These data have important implications for the mechanism of the oxidative stress development under the influence of high dose of ascorbic acid, indicating the importance of the side reactions of the mitochondrial electron transport chain with the formation of semiquinone radicals and the role of transition metals in this process.

  7. High pitch CT in triple rule-out studies: Radiation dose and image quality compared to multidetector CT.

    Science.gov (United States)

    Fernández del Valle, A; Delgado Sánchez-Gracián, C; Oca Pernas, R; Grande Astorquiza, A; Bustos Fiore, A; Trinidad López, C; Tardáguila de la Fuente, G

    2015-01-01

    To compare the image quality and radiation dose from high pitch dual source CT (128-DSCT) versus those from retrospective acquisition with 64-row multidetector CT (64-MDCT) in triple rule-out studies. We retrospectively studied 60 patients with acute chest pain: 30 with a retrospective EKG acquisition with 64-MDCT and 30 with high pitch 128-DSCT. We quantitatively analyzed the image quality by calculating the vascular density, muscular density (DM), noise, vascular density/noise ratio (VDNR), and contrast/noise ratio (CNR). We qualitatively evaluated the artifacts in the vena cava, aorta, and coronary arteries. We estimated the effective dose (ED) of radiation by means of the dose-length product. There were no significant differences between 128-DSCT and 64-MDCT in the vascular density. The VDNR and CNR were higher on 128-DSCT than on 64-MDCT in the aorta (VDNR: 28.9 ± 11.7 vs. 20 ± 5.5; CNR: 24.4 ± 10.9 vs. 16.8 ± 5.4; P<.01), in the pulmonary arteries (VDNR: 25.5 ± 10 vs. 20.6 ± 6.5; CNR: 24.5 ± 5.4 vs. 17.4 ± 6.4; P<.01), and in the coronary arteries (VDNR: 25.9 ± 8.2 vs. 18.9 ± 4.9; CNR: 24.9 ± 8.2 vs. 15.6 ± 4.6; P<.01). There were fewer artifacts in the coronary arteries on 128-DSCT than on 64-MDCT (3 vs. 34 nondiagnostic segments; P<.001), and the ED in 128-DSCT was lower than in 64-MDCT (13.77 ± 4 vs. 2.77 ± 0.6 mSv; P<.001). In triple rule-out studies, high pitch 128-DSCT delivers a lower dose of radiation and provides better image quality than retrospective acquisition with 64-MDCT. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  8. Double dose: High family conflict enhances the effect of media violence exposure on adolescents’ aggression

    NARCIS (Netherlands)

    Fikkers, K.M.; Piotrowski, J.T.; Weeda, W.D.; Vossen, H.G.M.; Valkenburg, P.M.

    2013-01-01

    We investigated how exposure to media violence and family conflict affects adolescents’ subsequent aggressive behavior. We expected a double dose effect, meaning that high media violence exposure would lead to higher levels of aggression for adolescents in high conflict families compared to low

  9. Double dose: High family conflict enhances the effect of media violence exposure on adolescents’ aggression

    NARCIS (Netherlands)

    Fikkers, K.M.; Piotrowski, J.T.; Weeda, W.D.; Vossen, H.G.M.; Valkenburg, P.M.

    2013-01-01

    We investigated how exposure to media violence and family conflict affects adolescents’ subsequent aggressive behavior. We expected a double dose effect, meaning that high media violence exposure would lead to higher levels of aggression for adolescents in high conflict families compared to low conf

  10. Double dose: High family conflict enhances the effect of media violence exposure on adolescents’ aggression

    NARCIS (Netherlands)

    Fikkers, K.M.; Piotrowski, J.T.; Weeda, W.D.; Vossen, H.G.M.; Valkenburg, P.M.

    2013-01-01

    We investigated how exposure to media violence and family conflict affects adolescents’ subsequent aggressive behavior. We expected a double dose effect, meaning that high media violence exposure would lead to higher levels of aggression for adolescents in high conflict families compared to low conf

  11. Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Bhavana [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Patel, Firuza D., E-mail: firuzapatel@gmail.com [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Chakraborty, Santam; Sharma, Suresh C.; Kapoor, Rakesh [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Aprem, Abi Santhosh [Corporate R and D Division, HLL Lifecare Limited, Karamana, Trivandrum (India)

    2013-04-01

    Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the second application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of

  12. Dosimetric properties of bio minerals applied to high-dose dosimetry using the TSEE technique

    Energy Technology Data Exchange (ETDEWEB)

    Vila, G. B.; Caldas, L. V. E., E-mail: gbvila@ipen.br [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil)

    2014-08-15

    The study of the dosimetric properties such as reproducibility, the residual signal, lower detection dose, dose-response curve and fading of the thermally stimulated emission exo electronic (TSEE) signal of Brazilian bio minerals has shown that these materials present a potential use as radiation dosimeters. The reproducibility within ± 10% for oyster shell, mother-of-pearl and coral reef samples showed that the signal dispersion is small when compared with the mean value of the measurements. The study showed that the residual signal can be eliminated with a thermal treatment at 300 grades C/1 h. The lower detection dose of 9.8 Gy determined for the oyster shell samples when exposed to beta radiation and 1.6 Gy for oyster shell and mother-of-pearl samples when exposed to gamma radiation can be considered good, taking into account the high doses of this study. The materials presented linearity at the dose response curves in some ranges, but the lack of linearity in other cases presents no problem since a good mathematical description is possible. The fading study showed that the loss of TSEE signal can be minimized if the samples are protected from interferences such as light, heat and humidity. Taking into account the useful linearity range as the main dosimetric characteristic, the tiger shell and oyster shell samples are the most suitable for high-dose dosimetry using the TSEE technique. (Author)

  13. The Effects of Erythropoietin Dose Titration during High-Fat Diet-Induced Obesity

    Directory of Open Access Journals (Sweden)

    Amanda Foskett

    2011-01-01

    Full Text Available Erythropoietin (Epo is a pleotropic cytokine with several nonhematopoietic tissue effects. High-dose Epo treatment-mediated effects on body weight, fat mass and glucose tolerance have recently been reported, thus extending its pleotropic effects to fat and glucose metabolism. However, the exact dose range of Epo treatment required for such effects remains unidentified to date. We investigated Epo dosage effect (up to 1000 U/kg on hematocrit, body weight, body composition, glucose metabolism, food intake, and physical activity, during high-fat diet-induced obesity. We report that Epo doses (1000, 600, 300, and 150 U/kg significantly reduced body weight gain and fat mass, while, only Epo doses of 300 U/kg and higher significantly affected glucose tolerance. None of the tested Epo doses showed any detectable effects on food intake, and only 1000 U/kg dose significantly increased physical activity, suggesting that these parameters may only be partially responsible for the metabolic effects of Epo treatment.

  14. Aging of magnesium stearate under high doses gamma irradiation and oxidative conditions

    Energy Technology Data Exchange (ETDEWEB)

    Lebeau, D.; Beuvier, L.; Cornaton, M. [CEA, DEN, DPC, SECR, LRMO, F-91191 Gif-sur-Yvette (France); Miserque, F. [CEA, DEN, DPC, SCCME, LECA, F-91191 Gif-sur-Yvette (France); Tabarant, M. [CEA, DEN, DPC, SEARS, LISL, F-91191 Gif-sur-Yvette (France); Esnouf, S. [CEA, DEN, DPC, SECR, LRMO, F-91191 Gif-sur-Yvette (France); Ferry, M., E-mail: muriel.ferry@cea.fr [CEA, DEN, DPC, SECR, LRMO, F-91191 Gif-sur-Yvette (France)

    2015-05-15

    Highlights: • Magnesium stearate was radio-oxidized at very high doses using gamma-rays. • H{sub 2} emission was estimated as a function of the integrated dose. • Modifications in the organic solid were followed as a function of the integrated dose. • A non-exhaustive degradation mechanism of magnesium stearate was proposed. - Abstract: In nuclear waste packages conditioning processes, magnesium stearate is widely used because of its high lubricating properties. For safety purposes, the radiolytic degradation of these organic materials has to be better understood to be able to predict their aging in repository conditions. This study reports the radiolytic degradation of magnesium stearate, using gamma-rays at room temperature and under air. Modifications were followed using different analytical tools (XPS, ATR-FTIR, ICP-AES, ATG and mass spectrometry). It has been observed that molecules mainly formed up to 1000 kGy of gamma irradiation dose under radio-oxidation are alkanes, hydroperoxides, double bonds in the aliphatic chain, carboxylates with aliphatic chain shorter than the one of stearate and ketones. At a dose of 4000 kGy, dicarboxylic acids are observed: the formation of these molecules needs a dose of at least 1000 kGy to be created under radio-oxidation. These observations allow us to propose a non-exhaustive degradation mechanism of magnesium stearate under gamma-irradiation at room temperature and under air.

  15. A grid algorithm for high throughput fitting of dose-response curve data.

    Science.gov (United States)

    Wang, Yuhong; Jadhav, Ajit; Southal, Noel; Huang, Ruili; Nguyen, Dac-Trung

    2010-10-21

    We describe a novel algorithm, Grid algorithm, and the corresponding computer program for high throughput fitting of dose-response curves that are described by the four-parameter symmetric logistic dose-response model. The Grid algorithm searches through all points in a grid of four dimensions (parameters) and finds the optimum one that corresponds to the best fit. Using simulated dose-response curves, we examined the Grid program's performance in reproducing the actual values that were used to generate the simulated data and compared it with the DRC package for the language and environment R and the XLfit add-in for Microsoft Excel. The Grid program was robust and consistently recovered the actual values for both complete and partial curves with or without noise. Both DRC and XLfit performed well on data without noise, but they were sensitive to and their performance degraded rapidly with increasing noise. The Grid program is automated and scalable to millions of dose-response curves, and it is able to process 100,000 dose-response curves from high throughput screening experiment per CPU hour. The Grid program has the potential of greatly increasing the productivity of large-scale dose-response data analysis and early drug discovery processes, and it is also applicable to many other curve fitting problems in chemical, biological, and medical sciences.

  16. Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications

    Energy Technology Data Exchange (ETDEWEB)

    Shwetha, Bondel [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Ravikumar, Manickam, E-mail: drravikumarm@gmail.com [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Supe, Sanjay S.; Sathiyan, Saminathan [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Lokesh, Vishwanath [Department of Radiotherapy, Kidwai, Memorial Institute of Oncology, Bangalore (India); Keshava, Subbarao L. [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India)

    2012-04-01

    Various treatment planning systems are used to design plans for the treatment of cervical cancer using high-dose-rate brachytherapy. The purpose of this study was to make a dosimetric comparison of the 2 treatment planning systems from Varian medical systems, namely ABACUS and BrachyVision. The dose distribution of Ir-192 source generated with a single dwell position was compared using ABACUS (version 3.1) and BrachyVision (version 6.5) planning systems. Ten patients with intracavitary applications were planned on both systems using orthogonal radiographs. Doses were calculated at the prescription points (point A, right and left) and reference points RU, LU, RM, LM, bladder, and rectum. For single dwell position, little difference was observed in the doses to points along the perpendicular bisector. The mean difference between ABACUS and BrachyVision for these points was 1.88%. The mean difference in the dose calculated toward the distal end of the cable by ABACUS and BrachyVision was 3.78%, whereas along the proximal end the difference was 19.82%. For the patient case there was approximately 2% difference between ABACUS and BrachyVision planning for dose to the prescription points. The dose difference for the reference points ranged from 0.4-1.5%. For bladder and rectum, the differences were 5.2% and 13.5%, respectively. The dose difference between the rectum points was statistically significant. There is considerable difference between the dose calculations performed by the 2 treatment planning systems. It is seen that these discrepancies are caused by the differences in the calculation methodology adopted by the 2 systems.

  17. Single versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning.

    Science.gov (United States)

    Bahadur, Yasir A; Constantinescu, Camelia; Hassouna, Ashraf H; Eltaher, Maha M; Ghassal, Noor M; Awad, Nesreen A

    2015-01-01

    To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. We randomly selected 12 patients with endometrial carcinoma, who received adjuvant vaginal cuff HDR brachytherapy using a multichannel applicator. For each brachytherapy fraction, two inverse treatment plans (for central channel and multichannel loadings) were performed and compared. The advantage of fractional re-planning was also investigated. Dose-volume-histogram (DVH) analysis showed limited, but statistically significant difference (p = 0.007) regarding clinical-target-volume dose coverage between single and multichannel approaches. For the organs-at-risk rectum and bladder, the use of multichannel applicator demonstrated a noticeable dose reduction, when compared to single channel, but statistically significant for rectum only (p = 0.0001). For D2cc of rectum, an average fractional dose of 6.1 ± 0.7 Gy resulted for single channel vs. 5.1 ± 0.6 Gy for multichannel. For D2cc of bladder, an average fractional dose of 5 ± 0.9 Gy occurred for single channel vs. 4.9 ± 0.8 Gy for multichannel. The dosimetric benefit of fractional re-planning was demonstrated: DVH analysis showed large, but not statistically significant differences between first fraction plan and fractional re-planning, due to large inter-fraction variations for rectum and bladder positioning and filling. Vaginal HDR brachytherapy using a multichannel vaginal applicator and inverse planning provides dosimetric advantages over single channel cylinder, by reducing the dose to organs at risk without compromising the target volume coverage, but at the expense of an increased vaginal mucosa dose. Due to large inter-fraction dose variations, we recommend individual fraction treatment plan optimization.

  18. The Effect of High-Dose Ionizing Radiation on the Astrobiological Model Lichen Circinaria gyrosa

    Science.gov (United States)

    de la Torre, Rosa; Zélia Miller, Ana; Cubero, Beatriz; Martín-Cerezo, M. Luisa; Raguse, Marina; Meeßen, Joachim

    2017-02-01

    The lichen Circinaria gyrosa is an astrobiological model defined by its high capacity of resistance to space conditions and to a simulated martian environment. Therefore, it became part of the currently operated BIOMEX experiment on board the International Space Station and the recent STARLIFE campaign to study the effects of four types of space-relevant ionizing radiation. The samples were irradiated with helium and iron ions at doses up to 2 kGy, with X-rays at doses up to 5 kGy and with γ rays at doses from 6 to 113 kGy. Results on C. gyrosa's resistance to simulated space ionizing radiation and its post-irradiation viability were obtained by (i) chlorophyll a fluorescence of photosystem II (PSII), (ii) epifluorescence microscopy, (iii) confocal laser scanning microscopy (CLSM), and (iv) field emission scanning electron microscopy (FESEM). Results of photosynthetic activity and epifluorescence show no significant changes up to a dose of 1 kGy (helium ions), 2 kGy (iron ions), 5 kGy (X-rays) - the maximum doses applied for those radiation qualities - as well as a dose of 6 kGy of γ irradiation, which was the lowest dose applied for this low linear energy transfer (LET) radiation. Significant damage in a dose-related manner was observed only at much higher doses of γ irradiation (up to 113 kGy). These data corroborate the findings of the parallel STARLIFE studies on the effects of ionizing radiation on the lichen Circinaria gyrosa, its isolated photobiont, and the lichen Xanthoria elegans.

  19. Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications.

    Science.gov (United States)

    Shwetha, Bondel; Ravikumar, Manickam; Supe, Sanjay S; Sathiyan, Saminathan; Lokesh, Vishwanath; Keshava, Subbarao L

    2012-01-01

    Various treatment planning systems are used to design plans for the treatment of cervical cancer using high-dose-rate brachytherapy. The purpose of this study was to make a dosimetric comparison of the 2 treatment planning systems from Varian medical systems, namely ABACUS and BrachyVision. The dose distribution of Ir-192 source generated with a single dwell position was compared using ABACUS (version 3.1) and BrachyVision (version 6.5) planning systems. Ten patients with intracavitary applications were planned on both systems using orthogonal radiographs. Doses were calculated at the prescription points (point A, right and left) and reference points RU, LU, RM, LM, bladder, and rectum. For single dwell position, little difference was observed in the doses to points along the perpendicular bisector. The mean difference between ABACUS and BrachyVision for these points was 1.88%. The mean difference in the dose calculated toward the distal end of the cable by ABACUS and BrachyVision was 3.78%, whereas along the proximal end the difference was 19.82%. For the patient case there was approximately 2% difference between ABACUS and BrachyVision planning for dose to the prescription points. The dose difference for the reference points ranged from 0.4-1.5%. For bladder and rectum, the differences were 5.2% and 13.5%, respectively. The dose difference between the rectum points was statistically significant. There is considerable difference between the dose calculations performed by the 2 treatment planning systems. It is seen that these discrepancies are caused by the differences in the calculation methodology adopted by the 2 systems.

  20. Relationship between the exposure dose of high intensity focused ultrasound and the heated necrosis element

    Institute of Scientific and Technical Information of China (English)

    FENG Ruo; ZHANG Qiang; LI Faqi; ZHENG Xiaozheng; BAI Jin; XU Jianyi; WANG Yaojun; WANG Zhibiao

    2004-01-01

    Heated necrosis element of tissues is the basis for treating tumor by high intensity focused ultrasound (HIFU), so study on the relationship between the HIFU exposure dose and the heated necrosis element of tissues is of great significance for both HIFU clinical applications and basic research. Using Pennes and Rayleigh formulae the relationship between the exposure dose of an annular focused transducer and the heated necrosis element (I.e. Biological focused region) in a bovine liver in vitro at a depth of 2 cm is simulated in an exposure dose range with radiation sound intensity of 7000~25400 W/cm2 and exposure time of 0~20 s. The theoretical results appear to be in quite good agreement with the experimental ones. It is shown that on the basis of existing theories the heated necrosis element produced by HIFU exposure can be predicted. The deviation of the theory from the experiments under higher exposure dose has also been discussed.

  1. Pulmonary edema following high intravenous doses of diatrizoate in the rat

    Energy Technology Data Exchange (ETDEWEB)

    Maare, K.; Violante, M.; Zack, A.

    Serious adverse reactions to intravenous contrast media are rare but of major concern. Corticosteroids are the most commonly used drugs for prophylaxis but there is little documentation of their effectiveness. Controversy also exists about the optimum regime for these drugs. A rat model was used to evaluate the effect of methylprednisolone pretreatment for contrast media-induced pulmonary edema. Rats were given 40 mg methylprednisolone/kg intravenously at various time intervals before the intravenous injection of a high dose of diatrizoate (6 g I/kg). The combination of one dose of methylprednisolone at 24 hours plus another dose at 0.5 hours was the only regimen that caused a significant reduction in the degree of pulmonary edema induced by contrast media. This result provides support for the clinical regimen utilizing iterated doses of corticosteroids over a prolonged period of time. (orig.).

  2. Preparation of an application for the control of the dose delivered by equipment of computed tomography (CT); Elaboracion de una aplicacion para el control de la dosis impartida por equipos de tomografia computerizada (TC)

    Energy Technology Data Exchange (ETDEWEB)

    Torres Cabrera, R.; Agulla Otero, M.; Hernando Gonzalez, I.

    2013-07-01

    Although TC are native digital equipment, the collection and treatment of the doses given to the patients it continues to present difficulties to date, especially in the still very large number of teams that do not produce a formal report of dose (SR). This work shows the experience gained in the development of an application that allows the calculation, monitoring and control of the dose given to patients by teams of TC. (Author)

  3. Lack of high-dose radiation mediated prostate cancer promotion and low-dose radiation adaptive response in the TRAMP mouse model.

    Science.gov (United States)

    Lawrence, M D; Ormsby, R J; Blyth, B J; Bezak, E; England, G; Newman, M R; Tilley, W D; Sykes, P J

    2013-10-01

    Cancer of the prostate is a highly prevalent disease with a heterogeneous aetiology and prognosis. Current understanding of the biological mechanisms underlying the responses of prostate tissue to ionizing radiation exposure, including cancer induction, is surprisingly limited for both high- and low-dose exposures. As population exposure to radiation increases, largely through medical imaging, a better understanding of the response of the prostate to radiation exposure is required. Low-dose radiation-induced adaptive responses for increased cancer latency and decreased cancer frequency have been demonstrated in mouse models, largely for hematological cancers. This study examines the effects of high- and low-dose whole-body radiation exposure on prostate cancer development using an autochthonous mouse model of prostate cancer: TRansgenic Adenocarcinoma of the Mouse Prostate (TRAMP). TRAMP mice were exposed to single acute high (2 Gy), low (50 mGy) and repeated low (5 × 50 mGy) doses of X rays to evaluate both the potential prostate cancer promoting effects of high-dose radiation and low-dose adaptive response phenomena in this prostate cancer model. Prostate weights and histopathology were examined to evaluate gross changes in cancer development and, in mice exposed to a single 2 Gy dose, time to palpable tumor was examined. Proliferation (Ki-67), apoptosis, DNA damage (γ-H2AX) and transgene expression (large T-antigen) were examined within TRAMP prostate sections. Neither high- nor low-dose radiation-induced effects on prostate cancer progression were observed for any of the endpoints studied. Lack of observable effects of high- or low-dose radiation exposure suggests that modulation of tumorigenesis in the TRAMP model is largely resistant to such exposures. However, further study is required to better assess the effects of radiation exposure using alternative prostate cancer models that incorporate normal prostate and in those that are not driven by SV40 large T

  4. High-dose inhaled terbutaline increases muscle strength and enhances maximal sprint performance in trained men

    DEFF Research Database (Denmark)

    Hostrup, Morten; Kalsen, Anders; Bangsbo, Jens

    2014-01-01

    PURPOSE: The purpose of the present study was to investigate the effect of high-dose inhaled terbutaline on muscle strength, maximal sprinting, and time-trial performance in trained men. METHODS: Nine non-asthmatic males with a [Formula: see text] of 58.9 ± 3.1 ml min(-1) kg(-1) (mean ± SEM......) participated in a double-blinded randomized crossover study. After administration of inhaled terbutaline (30 × 0.5 mg) or placebo, subjects' maximal voluntary isometric contraction (MVC) of m.quadriceps was measured. After MVC, subjects performed a 30-s Wingate test. Sixty minutes following the Wingate test...... was not different between treatments (P = 0.236). CONCLUSION: High-dose inhaled terbutaline elicits a systemic response that enhances muscle strength and sprint performance. High-dose terbutaline should therefore continue to be restricted in competitive sport....

  5. Sustained effect after lowering high-dose infliximab in patients with rheumatoid arthritis: a prospective dose titration study.

    NARCIS (Netherlands)

    Bemt, B.J. van den; Broeder, AA den; Snijders, G.F.; Hekster, Y.A.; Riel, P.L.C.M. van; Benraad, B.; Wolbink, G.J.; Hoogen, F.H.J. van den

    2008-01-01

    OBJECTIVES: In clinical trials only a small subset of patients with rheumatoid arthritis (RA) benefits from higher than standard dose of infliximab (>3 mg/kg/8 weeks). However, dose escalation of infliximab is frequently applied in clinical practice. Individual adjustment of infliximab treatment

  6. Fundamental investigations of natural and laboratory generated SAR dose response curves for quartz OSL in the high dose range

    DEFF Research Database (Denmark)

    Timar-Gabor, Alida; Constantin, Daniela; Buylaert, Jan-Pieter;

    2015-01-01

    SAR-OSL investigations on quartz from Romanian loess resulted in non concordant fine and coarse-grain ages for equivalent doses higher than ~100 Gy. The laboratory dose response for both grain sizes is well represented by a sum of two saturating exponential functions, fine and coarse grains chara...

  7. High-temperature thermoluminescence of anion-deficient alumina and possibilities of its application in high-dose dosimetry

    Science.gov (United States)

    Surdo, A. I.; Milman, I. I.; Abashev, R. M.; Vlasov, M. I.

    2014-12-01

    Results of studies of the thermoluminescence (TL) of anion-deficient alumina (α-Al2O3 - δ) single crystals and based on them TLD-500 detectors exposed to pulsed X-ray and electron radiation in a wide range of doses D, pulsed dose rates P p , and temperatures are described. The TL responses of α-Al2O3 - δ for continuous and pulsed X-ray irradiation at D = 0.05-150 Gy are compared. Unlike continuous irradiation, in the case of pulsed irradiation at P p ≥ 6 × 106 Gy/s, a linear increase in the TL response as a function of D is registered in the main and "chromium" peaks at 450 and 580 K, respectively, with a decrease in the slope of the dose dependence at D > 2 Gy for the peak at 450 K. It is found that high-dose irradiation (>60 Gy) leads to the formation of a new TL peak at 830 K and the preferential redistribution of the stored light sums into this peak. The dose dependence for the TL peak at 830 K is studied. It is established that it is linear in a super-high dose range of 104 to 6 × 106 Gy at P p = 2.6 × 1011 Gy/s.

  8. Impact of high dose versus low dose atorvastatin on contrast induced nephropathy in diabetic patients with acute coronary syndrome undergoing early percutaneous coronary intervention

    Directory of Open Access Journals (Sweden)

    Haitham Galal

    2015-12-01

    Conclusion: No significant difference between high and low doses of atorvastatin in preventing CIN in diabetic patients with normal or mild renal impairment presenting with acute coronary syndrome who underwent early PCI.

  9. Efficacy of High-Dose Baclofen for Alcohol Use Disorder and Comorbid Bulimia: A Case Report.

    Science.gov (United States)

    Weibel, Sébastien; Lalanne, Laurence; Riegert, Myriam; Bertschy, Gilles

    2015-01-01

    High-dose baclofen is a promising treatment for alcohol use disorder, with a specific action on craving. A more general action on craving in other addictive disorders has been suggested based on the hypothesis of a common neurobiological pathway in addictions. We report the case of a woman with both alcohol use disorder and bulimia nervosa. There was a positive response to high-dose baclofen on alcohol craving, but no response on food craving. The case illustrates that craving could be differentially responsive to anti-craving drugs.

  10. High-dose intravenous IgG treatment and renal function.

    Science.gov (United States)

    Schifferli, J; Leski, M; Favre, H; Imbach, P; Nydegger, U; Davies, K

    1991-02-23

    In an open trial of high dose intravenous IgG (IVIG) treatment in nephrotic patients with glomerulonephritis, the first six patients so far studied showed a transient rise in plasma creatinine. This increase was not associated with any symptoms and the urinary deposit remained unchanged. Two other patients with pre-existing renal impairment but without nephrotic syndrome had a transient and reversible rise in plasma creatinine immediately after IVIG. These observations suggest that high-dose IVIG infusion can produce short-lived disturbances in renal function in patients with kidney diseases.

  11. Mucormycoses: serious complication of high-dose corticosteroid therapy for traumatic optic neuropathy.

    Science.gov (United States)

    Dojcinovic, I; Richter, M

    2008-04-01

    Mucormycosis is harmless to a healthy person, but can cause opportunistic infections in immunocompromised patients, and once it has invaded internal organs is frequently fatal. Traumatic optic neuropathy is a rare complication of maxillofacial trauma. Management is controversial, and there are no treatment guidelines in the literature. The main methods of treatment of this condition employed today are high-dose corticosteroids and surgical optic nerve decompression, either alone or in combination. In this case, the patient was in good health, but received high-dose corticosteroids for 2 weeks, which temporarily diminished immune response and permitted the development of mucormycosis.

  12. Dose response of multiple parameters for calyculin A-induced premature chromosome condensation in human peripheral blood lymphocytes exposed to high doses of cobalt-60 gamma-rays.

    Science.gov (United States)

    Lu, Xue; Zhao, Hua; Feng, Jiang-Bin; Zhao, Xiao-Tao; Chen, De-Qing; Liu, Qing-Jie

    2016-09-01

    Many studies have investigated exposure biomarkers for high dose radiation. However, no systematic study on which biomarkers can be used in dose estimation through premature chromosome condensation (PCC) analysis has been conducted. The present study aims to screen the high-dose radiation exposure indicator in calyculin A-induced PCC. The dose response of multiple biological endpoints, including G2/A-PCC (G2/M and M/A-PCC) index, PCC ring (PCC-R), ratio of the longest/shortest length (L/L ratio), and length and width ratio of the longest chromosome (L/B ratio), were investigated in calyculin A-induced G2/A-PCC spreads in human peripheral blood lymphocytes exposed to 0-20Gy (dose-rate of 1Gy/min) cobalt-60 gamma-rays. The G2/A-PCC index was decreased with enhanced absorbed doses of 4-20Gy gamma-rays. The G2/A PCC-R at 0-12Gy gamma-rays conformed to Poisson distribution. Three types of PCC-R were scored according to their shape and their solidity or hollowness. The frequencies of hollow PCC-R and PCC-R including or excluding solid ring in G2/A-PCC spreads were enhanced with increased doses. The length and width of the longest chromosome, as well as the length of the shortest chromosome in each G2/M-PCC or M/A-PCC spread, were measured. All L/L or L/B ratios in G2/M-PCC or M/A-PCC spread increased with enhanced doses. A blind test with two new irradiated doses was conducted to validate which biomarker could be used in dose estimation. Results showed that hollow PCC-R and PCC-R including solid ring can be utilized for accurate dose estimation, and that hollow PCC-R was optimal for practical application.

  13. Efficacy and tolerability of high oral doses of levetiracetam in children with epilepsy.

    Science.gov (United States)

    Obeid, Makram; Pong, Amanda W

    2010-09-01

    Despite the advent of new antiepileptic drugs, many children continue to have refractory seizures. We sought to determine whether oral LEV is helpful in seizure control and tolerable at doses higher than 60mg/kg/day in the pediatric outpatient population. A retrospective chart review over a 1.5-year period was performed at the Columbia Comprehensive Epilepsy Center to identify children who were treated with levetiracetam doses titrated above the usual 40-60mg/kg/day. Data was collected on seizure semiology, epilepsy type, seizure frequency, concomitant antiepileptic drugs, and adverse effects. Thirty-two children, ranging in age from 1 to 19 years, required high dose levetiracetam. The median dosage of levetiracetam was 146mg/kg/day (range, 70-275mg/kg/day), and the median maximum serum trough level was 43mcg/ml (range, 20-121mcg/ml). All but one patient were taking one or more other antiepileptic drugs. A more than 50% reduction in seizure frequency was observed in 14 children (44%), with 5 achieving seizure freedom (16%). No response to high dose levetiracetam was found in 14 children (44%), and worsening of seizure frequency occurred in 4 (12%). Adverse effects were observed in 4 patients (12%), and were behavioral. Not only do some children tolerate high doses and serum levels of levetiracetam, but they may also benefit from them, suggesting that doses higher than 60mg/kg/day may be considered in children who partially respond to the lower doses. Copyright 2010 Elsevier B.V. All rights reserved.

  14. High-Dose versus Low-Dose Vitamin D Supplementation and Arterial Stiffness among Individuals with Prehypertension and Vitamin D Deficiency

    Directory of Open Access Journals (Sweden)