WorldWideScience

Sample records for degrees head-up tilt

  1. On the frequency and reproducibility of orthostatic blood pressure changes in healthy community-dwelling elderly during 60-degree head-up tilt.

    Science.gov (United States)

    Patel, A; Maloney, A; Damato, A N

    1993-07-01

    The postural effects of 20 minutes of 60-degree head-up tilt on systolic, diastolic, and mean arterial blood pressures (BPs), heart rate, and rhythm were studied in 70 healthy, community-dwelling volunteer subjects of both sexes, divided into three age groups. Group A consisted of 30 subjects, with a mean age of 76 years (range 65 to 95 years); group B had 19 subjects, with a mean age of 54 years (range 45 to 64 years); and group C had 21 subjects, with a mean age of 33 years (range 24 to 44 years). To qualify, subjects had to have a systolic BP of 150 mm Hg or less and a diastolic BP of 20 mm Hg (p < 0.05). The mean time for the systolic blood pressure drops in group A was 9.2 minutes. Results were reproducible upon retesting after 1 week.

  2. The impact of gravity during head-up tilt

    DEFF Research Database (Denmark)

    Olufsen, Mette; Smith, Brittany; Mehlsen, Jesper

    2011-01-01

    The impact of gravity during head-up tilt, a test often used in the clinic to diagnose patients who suffer from dizziness or frequent episodes of syncope, is not well described. This study uses mathematical modeling to analyze experimental blood pressure data measured at the level of the aorta...

  3. Effect of serotonin receptor blockade on endocrine and cardiovascular responses to head-up tilt in humans

    DEFF Research Database (Denmark)

    Matzen, S; Secher, N H; Knigge, U

    1993-01-01

    Effects of blockade of serotonin (5-HT) receptors on the integrated cardiovascular and endocrine adaptations during head-up tilt were investigated in normal men. In control experiments 50 degrees head-up tilt increased heart rate (HR), total peripheral resistance (TPR), plasma renin activity (PRA...

  4. The impact of gravity during head-up tilt

    DEFF Research Database (Denmark)

    Ottesen, Johnny T.; Olufsen, Mette; Smith, Brittany

    The impact of gravity during head-up tilt, a test often used in the clinic to diagnose patients who suffer from dizziness or frequent episodes of syncope, is not well described. This study uses mathematical modeling to analyze experimental blood pressure data measured at the level of the aorta...... a model predicting hydrostatic height between the two locations. Results from this model were compared with measurements. Furthermore, we show, using a differential equations model predicting blood pressure, that it is possible to predict blood pressure measured at the level of the carotid sinuses using...

  5. The impact of gravity during head-up tilt

    DEFF Research Database (Denmark)

    Ottesen, Johnny T.; Olufsen, Mette; Smith, Brittany

    and the carotid sinuses in a healthy volunteer. During head-up tilt the head is lifted above the heart stimulating gravitational pooling of blood in the lower extremities. This shift in volume is followed by an increase in blood pressure in the lower body, while the pressure in the head decreases, while...... a model predicting hydrostatic height between the two locations. Results from this model were compared with measurements. Furthermore, we show, using a differential equations model predicting blood pressure, that it is possible to predict blood pressure measured at the level of the carotid sinuses using...

  6. BARORECEPTOR REFLEX RESPONSE IN PARAPLEGIA DURING HEAD-UP TILT POSITION

    Directory of Open Access Journals (Sweden)

    Madhuri B.A

    2012-12-01

    Full Text Available Paraplegia is one of the most common spinal cord lesions seen in spinal cord injury patients below 4th thoracic vertebra and is associated with autonomic loss below the level of lesion with intact vagal cardiac nerves. It occurs due to lesion of spinal cord at an appropriate level. i.e., sparing superior extremities and involving inferior extremities. The common causes of paraplegia are accidents such as gunshot injuries, spinal cord injuries, autonomic injuries and dislocation of spine. The degree of cardiovascular control impairment is related to the level and severity of the lesion. This study was to investigate the autonomic control of cardio vascular functions in paraplegia patients in response to head up tilt following spinal cord injury. The parameter studies were in head up tilt response on resting heart rate and blood pressure changes in paraplegic subjects. The results show an abnormal response to head – up tilt in paraplegia patients with decrease in diastolic blood pressure but the heart rate showed normal response. Thus, in patients of paraplegia, sympathetic reflexes below the level of the lesion induce vasoconstriction. These results indicate that increased sympathetic activity in controls during Head up tilt and decreased sympathetic activity in paraplegia. This suggests that patients with paraplegia maintain cardiovascular homeostasis during Head up tilt without increase in sympathetic activity.

  7. A cardiovascular mathematical model of graded head-up tilt.

    Directory of Open Access Journals (Sweden)

    Einly Lim

    Full Text Available A lumped parameter model of the cardiovascular system has been developed and optimized using experimental data obtained from 13 healthy subjects during graded head-up tilt (HUT from the supine position to [Formula: see text]. The model includes descriptions of the left and right heart, direct ventricular interaction through the septum and pericardium, the systemic and pulmonary circulations, nonlinear pressure volume relationship of the lower body compartment, arterial and cardiopulmonary baroreceptors, as well as autoregulatory mechanisms. A number of important features, including the separate effects of arterial and cardiopulmonary baroreflexes, and autoregulation in the lower body, as well as diastolic ventricular interaction through the pericardium have been included and tested for their significance. Furthermore, the individual effect of parameter associated with heart failure, including LV and RV contractility, baseline systemic vascular resistance, pulmonary vascular resistance, total blood volume, LV diastolic stiffness and reflex gain on HUT response have also been investigated. Our fitted model compares favorably with our experimental measurements and published literature at a range of tilt angles, in terms of both global and regional hemodynamic variables. Compared to the normal condition, a simulated congestive heart failure condition produced a blunted response to HUT with regards to the percentage changes in cardiac output, stroke volume, end diastolic volume and effector response (i.e., heart contractility, venous unstressed volume, systemic vascular resistance and heart rate with progressive tilting.

  8. Reproducibility of heart rate variability, blood pressure variability and baroreceptor sensitivity during rest and head-up tilt

    DEFF Research Database (Denmark)

    Højgaard, Michael V; Agner, Erik; Kanters, Jørgen K

    2005-01-01

    (RR) interval and finger blood pressure (Finapres) in 14 healthy individuals on three different days. The protocol was 1 h of supine rest and 1 h of 60-degree head-up tilt. Time-series of consecutive 300-s segments as well as 1024-s segments of RR intervals and systolic, diastolic and mean blood...

  9. [Evaluation of psychological fear in children undergoing head-up tilt test].

    Science.gov (United States)

    Chu, Wei-Hong; Wu, Li-Jia; Wang, Cheng; Lin, Ping; Li, Fang; Zhu, Li-Ping; Ran, Jing; Zou, Run-Mei; Liu, De-Yu

    2014-03-01

    To investigate the effects of different tilt angles of head-up tilt test (HUTT) and different responses to HUTT on the psychological fear in children undergoing the test. HUTT was performed on children with unexplained syncope or pre-syncope (107 cases: 52 males and 55 females), aged 5.5-17.8 years (mean 12.0±2.8 years). All subjects were randomly assigned to undergo HUTT at an angle of 60°, 70° or 80°; the negative cases underwent sublingual nitroglycerin-provocation HUTT at the same tilt angle. The Wong-Baker Faces Pain Rating Scale was used for self-assessment of psychological fear in subjects during HUTT at the end point of the test. The positive rate, hemodynamic changes and distribution of response types showed no significant differences between children at tilt angles of 60°, 70° and 80° (P>0.05). The greater the tilt angle, the higher the degree of psychological fear in children undergoing the test, but there were no significant differences between them (P>0.05). The degree of psychological fear in children who showed a positive response to HUTT (n=76) was significantly higher than that in children who showed a negative response (n=31) (Ppsychological fear in children undergoing the test, and the degree of psychological fear increases in children tested at tilt angles from 60° to 80°, but the differences have no statistical significance. A positive response to HUTT can significantly increase the psychological fear in children.

  10. Leg blood flow measurements using venous occlusion plethysmography during head-up tilt.

    NARCIS (Netherlands)

    Kooijman, M.; Poelkens, F.; Rongen, G.A.; Smits, P.; Hopman, M.T.E.

    2007-01-01

    We tested whether venous occlusion plethysmography (VOP) is an appropriate method to measure calf blood flow (CBF) during head-up tilt (HUT). CBF measured with VOP was compared with superficial femoral artery blood flow as measured by Doppler ultrasound during incremental tilt angles. Measurements o

  11. Impaired Cerebral Autoregulation during Head Up Tilt in Patients with Severe Brain Injury

    DEFF Research Database (Denmark)

    Riberholt, Christian Gunge; Olesen, Niels Damkjær; Thing, Mira;

    2016-01-01

    acquired brain injury and a low level of consciousness. Fourteen patients with severe acquired brain injury and orthostatic intolerance and fifteen healthy volunteers were enrolled. Blood pressure was evaluated by pulse contour analysis, heart rate and RR-intervals were determined by electrocardiography...... mean velocity and estimated cerebral perfusion pressure. Patients with acquired brain injury presented an increase in mean flow index during head-up tilt indicating impaired autoregulation (P ....1 Hz spectral power in patients compared to healthy controls suggesting baroreflex dysfunction. In conclusion, patients with severe acquired brain injury and orthostatic intolerance during head-up tilt have impaired cerebral autoregulation more than one month after brain injury....

  12. Hyperoxia Improves Hemodynamic Status During Head-up Tilt Testing in Healthy Volunteers: A Randomized Study.

    Science.gov (United States)

    Fromonot, Julien; Chaumet, Guillaume; Gavarry, Olivier; Rostain, Jean-Claude; Lucciano, Michel; Joulia, Fabrice; Brignole, Michele; Deharo, Jean-Claude; Guieu, Regis; Boussuges, Alain

    2016-02-01

    Head-up tilt test is useful for exploring neurally mediated syncope. Adenosine is an ATP derivative implicated in cardiovascular disturbances that occur during head-up tilt test. The aim of the present study was to investigate the impact of hyperoxia on adenosine plasma level and on hemodynamic changes induced by head-up tilt testing.Seventeen healthy male volunteers (mean age 35 ± 11 years) were included in the study. The experiment consisted of 2 head-up tilt tests, 1 session with subjects breathing, through a mask, medical air (FiO2 = 21%) and 1 session with administration of pure oxygen (FiO2 = 100%) in double-blind manner. Investigations included continuous monitoring of hemodynamic data and measurement of plasma adenosine levels.No presyncope or syncope was found in 15 of the 17 volunteers. In these subjects, a slight decrease in systolic blood pressure was recorded during orthostatic stress performed under medical air exposure. In contrast, hyperoxia led to increased systolic blood pressure during orthostatic stress when compared with medical air. Furthermore, mean adenosine plasma levels decreased during hyperoxic exposure before (0.31 ± 0.08 μM) and during head-up tilt test (0.33 ± 0.09 μM) when compared with baseline (0.6 ± 0.1 μM). Adenosine plasma level was unchanged during medical air exposure at rest (0.6 ± 0.1 μM), and slightly decreased during orthostatic stress. In 2 volunteers, the head-up tilt test induced a loss of consciousness when breathing air. In these subjects, adenosine plasma level increased during orthostatic stress. In contrast, during hyperoxic exposure, the head-up tilt test did not induce presyncope or syncope. In these 2 volunteers, biological study demonstrated a decrease in adenosine plasma level at both baseline and during orthostatic stress for hyperoxic exposure compared with medical air.These results suggest that hyperoxia was able to increase blood pressure during head-up tilt

  13. Is absolute hypovolemia a risk factor for vasovagal response to head-up tilt?

    Science.gov (United States)

    Jaeger, F J; Maloney, J D; Castle, L W; Fouad-Tarazi, F M

    1993-04-01

    To test the hypothesis that hypovolemia is associated with an increased incidence of vasovagal syncope during head-up tilt (HUT) 45 patients with history of syncope or presyncope were studied. Blood volume (radio-iodinated serum albumin) was determined, then subjects underwent a graded HUT (from 15 degrees-60 degrees HUT) with cuff blood pressure and ECG monitoring. All patients were kept on their own medications during evaluation. Thirty patients (12 male, 18 female, mean age 50 +/- 19 [SD] years) had hypovolemia, defined as blood volume < 90% of lab normal for corresponding sex, while 15 patients (7 male, 8 female, mean age 52 +/- 21 years) were normovolemic with blood volume ranging from 91%-110% of sex-matched normal subjects. The normovolemic patients served as controls. During HUT, a vasovagal response was elicited in 5 of the 30 hypovolemics and in 4 of the 15 normovolemic (16.7% and 26.7%, respectively, P = NS). In those who developed vasovagal response, the changes of heart rate and blood pressure during HUT were not significantly different between hypovolemics and normovolemics, neither at the endpoint (vasovagal response) nor immediately before the development of the vasovagal response. In patients with nonvasovagal events, four types of hemodynamic responses to tilt were observed: normal blood pressure response associated with normal heart rate increase, normal blood pressure response in association with accentuated increase in heart rate, orthostatic hypotension with normal acceleration of heart rate, and orthostatic hypotension with accelerated increase in heart rate.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Impaired Cerebral Autoregulation during Head Up Tilt in Patients with Severe Brain Injury.

    Directory of Open Access Journals (Sweden)

    Christian Gunge Riberholt

    Full Text Available Early mobilization is of importance for improving long-term outcome for patients after severe acquired brain injury. A limiting factor for early mobilization by head-up tilt is orthostatic intolerance. The purpose of the present study was to examine cerebral autoregulation in patients with severe acquired brain injury and a low level of consciousness. Fourteen patients with severe acquired brain injury and orthostatic intolerance and fifteen healthy volunteers were enrolled. Blood pressure was evaluated by pulse contour analysis, heart rate and RR-intervals were determined by electrocardiography, middle cerebral artery velocity was evaluated by transcranial Doppler, and near-infrared spectroscopy determined frontal lobe oxygenation in the supine position and during head-up tilt. Cerebral autoregulation was evaluated as the mean flow index calculated as the ratio between middle cerebral artery mean velocity and estimated cerebral perfusion pressure. Patients with acquired brain injury presented an increase in mean flow index during head-up tilt indicating impaired autoregulation (P < 0.001. Spectral analysis of heart rate variability in the frequency domain revealed lower magnitudes of ~0.1 Hz spectral power in patients compared to healthy controls suggesting baroreflex dysfunction. In conclusion, patients with severe acquired brain injury and orthostatic intolerance during head-up tilt have impaired cerebral autoregulation more than one month after brain injury.

  15. Impaired Cerebral Autoregulation during Head Up Tilt in Patients with Severe Brain Injury

    DEFF Research Database (Denmark)

    Riberholt, Christian Gunge; Olesen, Niels Damkjær; Thing, Mira;

    2016-01-01

    acquired brain injury and a low level of consciousness. Fourteen patients with severe acquired brain injury and orthostatic intolerance and fifteen healthy volunteers were enrolled. Blood pressure was evaluated by pulse contour analysis, heart rate and RR-intervals were determined by electrocardiography......, middle cerebral artery velocity was evaluated by transcranial Doppler, and near-infrared spectroscopy determined frontal lobe oxygenation in the supine position and during head-up tilt. Cerebral autoregulation was evaluated as the mean flow index calculated as the ratio between middle cerebral artery...

  16. Mesenteric artery response to head-up tilt-induced central hypovolaemia and hypotension

    DEFF Research Database (Denmark)

    Perko, M J; Madsen, P; Perko, Grazyna

    1997-01-01

    .01) and an increase in thoracic electric impedance from 38.6 +/- 2.1 to 42.6 +/- 2.1 omega (P 6 mmHg: P ...Superior mesenteric artery (SMA) blood flow and impedance were evaluated by duplex ultrasound during head-up tilt (HUT)-induced central hypovolaemia and hypotension in eight healthy volunteers. HUT induced a reduction in cardiac stroke volume from 88.8 +/- 6.3 to 64.7 +/- 6.3 ml (mean +/- SEM; P

  17. Mesenteric artery response to head-up tilt-induced central hypovolaemia and hypotension

    DEFF Research Database (Denmark)

    Perko, M J; Madsen, P; Perko, Grazyna

    1997-01-01

    Superior mesenteric artery (SMA) blood flow and impedance were evaluated by duplex ultrasound during head-up tilt (HUT)-induced central hypovolaemia and hypotension in eight healthy volunteers. HUT induced a reduction in cardiac stroke volume from 88.8 +/- 6.3 to 64.7 +/- 6.3 ml (mean +/- SEM; P ... the normotensive and the hypotensive phase of HUT, the SMA diameter (5.7 +/- 0.03 mm) and blood flow (514 +/- 75 ml min-1) did not change significantly, although the end-diastolic velocity increased from 9.7 +/- 4.8 to 39.7 +/- 4.0 cm s-1 (P ... or reduced arterial pressure, supports a reduction in the SMA impedance as it was reproduced during a meal test when a moderate reduction in mean arterial pressure (87 +/- 4 to 80 +/- 4 mm Hg; P = 0.04) was accompanied by a ninefold increase in the end-diastolic velocity (P

  18. Contribution of perfusion pressure to vascular resistance response during head-up tilt

    Science.gov (United States)

    Imadojemu, V. A.; Lott, M. E.; Gleeson, K.; Hogeman, C. S.; Ray, C. A.; Sinoway, L. I.

    2001-01-01

    We measured brachial and femoral artery flow velocity in eight subjects and peroneal and median muscle sympathetic nerve activity (MSNA) in five subjects during tilt testing to 40 degrees. Tilt caused similar increases in MSNA in the peroneal and median nerves. Tilt caused a fall in femoral artery flow velocity, whereas no changes in flow velocity were seen in the brachial artery. Moreover, with tilt, the increase in the vascular resistance employed (blood pressure/flow velocity) was greater and more sustained in the leg than in the arm. The ratio of the percent increase in vascular resistance in leg to arm was 2.5:1. We suggest that the greater vascular resistance effects in the leg were due to an interaction between sympathetic nerve activity and the myogenic response.

  19. Prediction of head-up tilt test result: is it possible?

    Science.gov (United States)

    Turk, Ugur; Alioglu, Emin; Kirilmaz, Bahadir; Duygu, Hamza; Tuzun, Nurullah; Tengiz, Istemihan; Zoghi, Mehdi; Ercan, Ertugrul

    2010-02-01

    The determination of early, accurate, predictive criteria for a positive result would permit a reduction in the duration of the head-up tilt testing (HUTT). Previous studies propounded that existence of early sympathetic overreactivity (rapid and sustained increase in heart rate) during HUTT predicts positive result. However, the exact value of this variable is unknown. We analyzed the early heart rate (HR) responses to HUTT and evaluated their ability to predict HUTT result. Consecutive patients referred to the syncope unit of our center for recurrent unexplained syncope were studied. We studied 189 consecutive patients and 67 (35%) patients had a negative HUTT; 122 (65%) patients had a positive HUTT. The early HR increase was defined as the maximum HR during the first 10 minutes of tilting minus the resting HR before tilting. The receiver-operator curves (ROCs) show the overall performance of the HR changes for predicting the HUTT result. For all variables, area under the ROC curve (AUC) was nearly equivalent to 0.50 and early HR increase was not a predictor of the negative result of HUTT (AUC = 0.546). Also there was no any significant correlation between the magnitude of early HR increase and patient age (r =-0.03, P = 0.76). The results suggest that the early increase in HR during the first 10 minutes of the HUTT may not be a useful parameter for predicting the test result. Many factors, such as late exaggeration in sympathetic activity during HUTT and age-dependent reduction in baroreflex sensitivity, may attenuate the predictive value of early HR increase.

  20. Effect of isometric hand grip on heart rate in normotensive and hypertensive individuals during head up tilt (300 and 600)

    OpenAIRE

    Badwe, A. N.; Latti, Ramchandra Girimalappa

    2017-01-01

    Objective: To study the effect of isometric hand grip exercise at 20% on normotensive, treated hypertensive, and non treated hypertensive in supine position, and at 300 and 600 head up tilt.Material and Methods: After recording heart rate in supine position, isometric hand grip exercise at 20% was conducted for 2 minutes with dominant hand and heart rate was recorded for 1 minute in all subjects after end of the exercise. The same maneuver was repeated before head up tilt in supine position a...

  1. Constriction of collateral arteries induced by "head-up tilt" in patients with occlusive arterial disease of the legs

    DEFF Research Database (Denmark)

    Agerskov, K; Henriksen, O; Tønnesen, K H

    1981-01-01

    . Relative change in blood flow in the leg during tilt was estimated by changes in arterio-venous oxygen differences and by the indicator dilution technique in nine patients. Head-up tilt caused a decrease in leg blood flow of 36% corresponding to an increase in total vascular resistance of 57%. Tilt did......The effect of head-up tilt on leg blood flow and segmental arterial blood pressures was studied in 21 patients with occlusion or severe stenosis of the common or superficial femoral artery. Arterial pressure was measured directly in the brachial artery, common femoral artery and popliteal artery...... not change the pressure gradient from femoral to popliteal artery in the patients with occlusion of the superficial femoral artery, indicating that the flow resistance offered by the collateral arteries had increased. In a bilateral sympathectomised patient the increase in collateral resistance was almost...

  2. Finger arterial versus intrabrachial pressure and continuous cardiac output during head-up tilt testing in healthy subjects

    NARCIS (Netherlands)

    Jellema, W.T.; Imholz, B.P.M.; Goudoever, J. van; Wesseling, K.H.; Lieshout, J.J. van

    1996-01-01

    1. The aims of this study were to determine the clinical feasibility of continuous, non-invasive Finapres recordings as a replacement for intrabrachial pressure during a 30 min head-up tilt, and the reliability of continuous cardiac output computation by pulse contour analysis from the finger arteri

  3. Effect of hydration on plasma vasopressin, renin, and aldosterone responses to head-up tilt

    Science.gov (United States)

    Harrison, M. H.; Geelen, G.; Keil, L. C.; Wade, C. A.; Hill, L. C.

    1986-01-01

    If plasma vasopressin (PVP), plasma renin (PRA), and plasma aldosterone (PA) responses to change in posture are mediated only by alterations in intrathoracic baroreceptor activity hydration status should have minimal influence on these responses. To test this hypothesis, six male subjects underwent 45 min of 70 deg head-up tilt (HUT) following 26 h dehydration, and again, 105 min later, following rehydration. Compared with preceding supine hydrated control values, PVP, PRA, and PA increased (p less than 0.001) during dehydrated HUT, but only PVP and PRA increased during rehydrated HUT (p less than 0.001). The dissociation during rehydrated HUT of PRA and PA may have been related more to the reduction (p less than 0.001) in plasma potassium concentration than to the accompanying decrease (p less than 0.001) in plasma osmolality and sodium concentration. Although increases in PVP and PRA during HUT were attenuated (p less than 0.01) following rehydration, this attenuation was associated with the absence of symptoms of overt hypotension following rehydration. However, since rehydration did not abolish the increases in PVP and PRA induced by HUT, it is concluded that the present observations support the concept of intrathoracic baroreceptor involvement in the regulation of vasopressin secretion and renin release.

  4. Retrograde arterial leg blood flow during tilt-back from a head-up posture: importance of capacitive flows when arterial pressure changes.

    Science.gov (United States)

    Sheriff, Don D; Nådland, Inger Helene; Toska, Karin

    2010-03-01

    The windkessel function of the arterial system converts the intermittent action of the heart into more continuous microcirculatory blood flow during diastole via the return of elastic energy stored in the walls of the arteries during systole. Might the same phenomenon occur regionally within the arterial system during tilting owing to regional differences in local arterial pressure imposed by gravity? We sought to test the hypothesis that during tilt-back from a head-up posture, the return of stored elastic energy in leg arteries would work to slow, or perhaps transiently reverse, the flow of blood in the femoral artery. Femoral artery blood flow and arterial pressure were recorded during tilt back from a 30 degrees head-up posture to supine (approximately 0.5 G) in young, healthy subjects (n = 7 males and 3 females) before and during clonidine infusion. During control (no drug) conditions femoral artery blood flow ceased for an entire heart beat during tilt-back. During clonidine infusion femoral artery blood flow reversed for at least one entire heart beat during tilt-back, i.e., blood flow in the retrograde direction in the femoral artery from the leg into the abdomen. Thus substantial capacitive effects of tilting on leg blood flow occur in humans during mild changes in posture.

  5. Higher postural heart rate increments on head-up tilt correlate with younger age but not orthostatic symptoms.

    Science.gov (United States)

    Ives, Colleen T; Kimpinski, Kurt

    2013-08-15

    Reports have shown that younger individuals present with higher postural heart rate increments on head-up tilt (HUT). However, a correlation between the degree of heart rate increment and symptoms of orthostatic intolerance has not been determined. The objective of this study was to determine whether higher postural heart rate increments during HUT correlate with symptoms of orthostatic intolerance in healthy subjects. Postural heart rate increment on HUT did not differ between men and women (P = 0.48) but did show a significant decrease by age group (P orthostatic intolerance by sex (P = 0.03) but not age (P = 0.58). There was no significant correlation between either symptoms of orthostatic intolerance and age [r = -0.13 (-0.31, 0.06), r(2) = 0.017; P = 0.17] or heart rate increment on HUT and symptoms of orthostatic intolerance [r = 0.15 (-0.04, 0.33), r(2) = 0.022; P = 0.13]. The results demonstrate that higher postural heart rate increments in younger individuals do not result in an increase in orthostatic intolerance. This highlights the potential need for a reevaluation of the diagnostic criteria for postural orthostatic tachycardia syndrome in younger individuals.

  6. The Changes of Baroreflex Sensitivity During Head -up Tilt Test and Its Clinical Significance in the Patients with Vasovagal Syncope

    Institute of Scientific and Technical Information of China (English)

    胡兆霆; 吕艳青; 杨钧国

    2001-01-01

    Objective To study the changes of baroreflex sensitivity (BRS) during head -up tilt test (HUT) in patients with vasovagal syncope (VS),and to examine the relationship between baroreflex sensitivity and neurohormonal factors. Furthermore, to investigate the effects of the changes of BRS on VS.Methods Forty- two patients with unexplained syncope (Among the 42 patients, there were 22 patients with positive HUT and 20 patients with negative HUT respectively) and 20 healthy volunteers (with negative HUT) underwent passive head-up tilt testing, Antecubital vein blood samples were taken before and after HUT, or at syncope. The fasting plasma endothelin ,serum nitric oxide (NO), serum NE were measured. The BRS was assessed on the basis of the linear regression slope the RR interval versus systolic arterial blood pressure during the increment in blood pressure after intravenous administration of phenylephrine. Results ( 1 )During the syncope, the BRS significantly reduced in HUT( + ) group than baseline. At the end of tilt, the level of plasma ET, serum NO in patients with positive HUT significantly increased compared with baseline or normal controls, and the plasma concentration of NE also had the trend of increase. ( 2 ) By multiple regression analysis, a significant negative correlation was found between baroreceptor sensitivity and the plasma ET, NO at the end of HUT in patients with positive HUT, but there was no relationship between BRS and NE. Conclusions During the syncope occure, the BRS in patients with VS decreased significantly compared with normal controls. The abnormal plasma ET, NO concentration might contribute to the mechanism of VS.

  7. Computer program for analysis of hemodynamic response to head-up tilt test

    Science.gov (United States)

    Świątek, Eliza; Cybulski, Gerard; Koźluk, Edward; Piątkowska, Agnieszka; Niewiadomski, Wiktor

    2014-11-01

    The aim of this work was to create a computer program, written in the MATLAB environment, which enables the visualization and analysis of hemodynamic parameters recorded during a passive tilt test using the CNS Task Force Monitor System. The application was created to help in the assessment of the relationship between the values and dynamics of changes of the selected parameters and the risk of orthostatic syncope. The signal analysis included: R-R intervals (RRI), heart rate (HR), systolic blood pressure (sBP), diastolic blood pressure (dBP), mean blood pressure (mBP), stroke volume (SV), stroke index (SI), cardiac output (CO), cardiac index (CI), total peripheral resistance (TPR), total peripheral resistance index (TPRI), ventricular ejection time (LVET) and thoracic fluid content (TFC). The program enables the user to visualize waveforms for a selected parameter and to perform smoothing with selected moving average parameters. It allows one to construct the graph of means for any range, and the Poincare plot for a selected time range. The program automatically determines the average value of the parameter before tilt, its minimum and maximum value immediately after changing positions and the times of their occurrence. It is possible to correct the automatically detected points manually. For the RR interval, it determines the acceleration index (AI) and the brake index (BI). It is possible to save calculated values to an XLS with a name specified by user. The application has a user-friendly graphical interface and can run on a computer that has no MATLAB software.

  8. Distinctive Steady-State Heart Rate and Blood Pressure Responses to Passive Robotic Leg Exercise and Functional Electrical Stimulation During Head-up Tilt

    Directory of Open Access Journals (Sweden)

    Amirehsan Sarabadani Tafreshi

    2016-12-01

    Full Text Available Tilt tables enable early mobilization of patients by providing verticalization. But there is a high risk of orthostatic hypotension provoked by verticalization, especially after neurological diseases such as spinal cord injury. Robot-assisted tilt tables might be an alternative as they add passive robotic leg exercise (PE that can be enhanced with functional electrical stimulation (FES to the verticalization, thus reducing the risk of orthostatic hypotension. We hypothesized that the influence of PE on the cardiovascular system during verticalization depends on the verticalization angle, and FES strengthens the PE influence. To test our hypotheses, we investigated the PE effects on the cardiovascular parameters heart rate (HR, and systolic and diastolic blood pressures (sBP, dBP at different angles of verticalization in a healthy population. Ten healthy subjects on a robot-assisted tilt table underwent four different study protocols while HR, sBP and dBP were measured: (1 head-up tilt to 60° and 71° without PE; (2 PE at 20°, 40°, and 60° of head-up tilt; (3 PE while constant FES intensity was applied to the leg muscles, at 20°, 40°, and 60° of head-up tilt; (4 PE with variation of the applied FES intensity at 0°, 20°, 40°, and 60° of head-up tilt. Linear mixed models were used to model changes in HR, sBP, and dBP responses. The models show that: (1 head-up tilt alone resulted in statistically significant increases in HR and dBP, but no change in sBP. (2 PE during head-up tilt resulted in statistically significant changes in HR, sBP, and dBP, but not at each angle and not always in the same direction (i.e., increase or decrease of cardiovascular parameters. Neither adding (3 FES at constant intensity to PE nor (4 variation of FES intensity during PE had any statistically significant effects on the cardiovascular parameters.The effect of PE on the cardiovascular system during head-up tilt is strongly dependent on the verticalization

  9. Which is preferable for orthostatic hypotension diagnosis in older adults: active standing test or head-up tilt table test?

    Directory of Open Access Journals (Sweden)

    Aydin AE

    2017-01-01

    Full Text Available Ali Ekrem Aydin,1 Pinar Soysal,2 Ahmet Turan Isik1 1Center for Aging Brain and Dementia, Department of Geriatric Medicine, Faculty of Medicine, Dokuz Eylul University, Izmir, Turkey; 2Kayseri Education and Research Hospital, Geriatric Center, Kayseri, Turkey Background: Correct evaluation of orthostatic hypotension (OH is crucial in geriatric practice, since OH is associated with mortality and morbidity. The study aimed to determine the most appropriate method for measuring blood pressure in transition from supine to upright position in order to diagnose OH in older adults.Methods: Active standing test (AST and head-up tilt table (HUT test as well as comprehensive geriatric assessment (CGA, including mini-mental state examination or the cognitive state test, mini-nutritional assessment, basic and instrumental activities of daily living, and Tinetti performance-oriented mobility assessment indexes, were performed in 290 geriatric patients.Results: The prevalence of OH during HUT and AST was 19% and 37%, respectively. In patients with OH during HUT, the frequency of dementia and recurrent falls were higher (P<0.05; on the other hand, the levels of serum vitamin D and albumin and estimated glomerular filtration rate were lower (P<0.05. However, all these parameters for OH during AST were not significant (P>0.05. Comparison of the groups according to CGA measurements revealed significant differences in terms of cognition, nutritional status, activities of daily life, and balance function in patients with OH only during HUT (P<0.05, but not during AST (P>0.05. The sensitivity, specificity, positive predictive value, and negative predictive values of AST were 49.0%, 65.5%, 25.0%, and 84.6% respectively, according to HUT.Conclusion: The results suggest that orthostatic blood pressure changes determined by HUT might be of higher clinical significance than that by AST in older adults. It might be important that the evaluation of OH by HUT should be

  10. Differences in autonomic balance in patients with cardioinhibitory and vasodepressor type of reflex syncope during head-up tilt test and active standing

    DEFF Research Database (Denmark)

    Holmegard, Haya N; Benn, Marianne; Kaijer, Michelle;

    2012-01-01

    To improve the pathophysiological understanding of cardioinhibitory and vasodepressor reflex syncope, by evaluating orthostatic effects on electrical and hemodynamic variables. To unravel the pathogeneses further, we studied these effects during both the passive head-up tilt test and the active...

  11. Does mental arithmetic before head up tilt have an effect on the orthostatic cardiovascular and hormonal responses?

    Science.gov (United States)

    Goswami, Nandu; Lackner, Helmut Karl; Papousek, Ilona; Montani, Jean-Pierre; Jezova, Daniela; Hinghofer-Szalkay, Helmut G.

    2011-05-01

    Passive head up tilt (HUT) and mental arithmetic (MA) are commonly used for providing mental and orthostatic challenges, respectively. In animal experiments, even a single exposure to a stressor has been shown to modify the response to subsequent stress stimulus. We investigated whether MA applied before HUT elicits synergistic responses in orthostatic heart rate (HR), cardiac output (CO), heart rate variability and arterial blood pressure. The 15 healthy young males were subjected to two randomized protocols: (a) HUT and (b) HUT preceded by MA, with sessions randomized and ≥2 weeks apart. Beat to beat continuous hemodynamic variables were measured and saliva samples taken for hormonal assay. HUT alone increased HR from 59±7 (baseline) to 80±10 bpm (mean±SD) and mean blood pressure (MBP) from 88±10 to 91±14 mmHg. HUT results after MA were not different from those with HUT alone. The activity of alpha amylase showed differences during the experiments irrespective of the protocols. We conclude that mental challenge does not affect orthostatic cardiovascular responses when applied before; the timing of mental loading seems to be critical if it is intended to alter cardiovascular responses to upright standing.

  12. Which is preferable for orthostatic hypotension diagnosis in older adults: active standing test or head-up tilt table test?

    Science.gov (United States)

    Aydin, Ali Ekrem; Soysal, Pinar; Isik, Ahmet Turan

    2017-01-01

    Background Correct evaluation of orthostatic hypotension (OH) is crucial in geriatric practice, since OH is associated with mortality and morbidity. The study aimed to determine the most appropriate method for measuring blood pressure in transition from supine to upright position in order to diagnose OH in older adults. Methods Active standing test (AST) and head-up tilt table (HUT) test as well as comprehensive geriatric assessment (CGA), including mini-mental state examination or the cognitive state test, mini-nutritional assessment, basic and instrumental activities of daily living, and Tinetti performance-oriented mobility assessment indexes, were performed in 290 geriatric patients. Results The prevalence of OH during HUT and AST was 19% and 37%, respectively. In patients with OH during HUT, the frequency of dementia and recurrent falls were higher (P0.05). Comparison of the groups according to CGA measurements revealed significant differences in terms of cognition, nutritional status, activities of daily life, and balance function in patients with OH only during HUT (P0.05). The sensitivity, specificity, positive predictive value, and negative predictive values of AST were 49.0%, 65.5%, 25.0%, and 84.6% respectively, according to HUT. Conclusion The results suggest that orthostatic blood pressure changes determined by HUT might be of higher clinical significance than that by AST in older adults. It might be important that the evaluation of OH by HUT should be included in daily geriatric practice. PMID:28182163

  13. The mechanism of neurally mediated syncope assessed by an ambulatory radionuclide monitoring system and heart rate variability indices during head-up tilt

    Energy Technology Data Exchange (ETDEWEB)

    Hosaka, Haruhiko [Self Defense Force Central Hospital, Tokyo (Japan); Takase, Bonpei; Ohsuzu, Fumitaka [National Defense Medical Coll., Tokorozawa, Saitama (Japan); Kurita, Akira [National Defense Medical Coll., Tokorozawa, Saitama (Japan). Research Center

    2002-11-01

    Previously, we tested the hypothesis that the great decline in left ventricular volume during head-up tilt test could trigger ventricular mechanoreceptor activation, using ambulatory radionuclide monitoring system (C-VEST system). The aim of this study is to investigate the mechanism of tilt-induced syncope further, based on our previous report. We measured the temporal changes in left ventricular volume, ejection fraction, cardiac output, and heart rate variability indices during head-up tilt test in 34 patients with syncope of an undetermined etiology. Twenty-two patients and a positive response (P group). Twelve patients showed a negative response (N group). Before syncope, left ventricular volume declined (P group, diastolic volume; -7.9{+-}6.8%: systolic volume; -23.3{+-}33.8%: N group, diastolic volume; -2.5{+-}1.9%: systolic volume; 0.6{+-}9.5%: p<0.05), ejection fraction increased (P group, 3.9{+-}2.5%; N group, -3.5{+-}7.2%; p<0.005), and high frequency spectra increased (P group, 12.0{+-}20.3%; N group, 3.1{+-}9.7%; p<0.05), more extremely in the P group than in the N group. The value of the high frequency spectra before the head-up tilt test was significantly higher in the P group than in the N group (P group, 5.8{+-}0.9 ms; N group, 5.0{+-}1.1 ms; p<0.05). The precise evaluation of left ventricular volume by ambulatory radionuclide monitoring system combined with a heart rate variability analysis is considered to be useful for clarifying the pathophysiology of neurally mediated syncope. Patients with neurally mediated syncope have higher baseline parasympathetic tone than normal population. (author)

  14. Distinctive Steady-State Heart Rate and Blood Pressure Responses to Passive Robotic Leg Exercise during Head-Up Tilt: A Pilot Study in Neurological Patients

    Directory of Open Access Journals (Sweden)

    Amirehsan Sarabadani Tafreshi

    2017-06-01

    Full Text Available Introduction: Robot-assisted tilt table therapy was proposed for early rehabilitation and mobilization of patients after diseases such as stroke. A robot-assisted tilt table with integrated passive robotic leg exercise (PE mechanism has the potential to prevent orthostatic hypotension usually provoked by verticalization. In a previous study with rather young healthy subjects [average age: 25.1 ± 2.6 years (standard deviation], we found that PE effect on the cardiovascular system depends on the verticalization angle of the robot-assisted tilt table. In the current study, we investigated in an older population of neurological patients (a whether they show the same PE effects as younger healthy population on the cardiovascular system at different tilt angles, (b whether changing the PE frequency (i.e., stepping speed influences the PE effect on the cardiovascular system, (c whether PE could prevent orthostatic hypotension, and finally, (d whether PE effect is consistent from day to day.Methods: Heart rate (HR, and systolic and diastolic blood pressures (sBP, dBP in response to PE at two different tilt angles (α = 20°, 60° with three different PE frequencies (i.e., 0, 24, and 48 steps per minute of 10 neurological patients [average age: 68.4 ± 13.5 years (standard deviation] were measured on 2 consecutive days. Linear mixed models were used to develop statistical models and analyze the repeated measurements.Results: The models show that: PE significantly increased sBP and dBP but had no significant effect on HR. (a Similar to healthy subjects the effect of PE on sBP was dependent on the tilt angle with higher tilt angles resulting in a higher increase. Head-up tilting alone significantly increased HR and dBP but resulted in a non-significant drop in sBP. PE, in general, had a more additive effect on increasing BP. (b The effect of PE was not influenced by its speed. (c Neither during head-up tilt alone nor in combination with PE did

  15. Syncope as a health risk for soldiers:Influence of medical history and clinical findings on the sensitivity of head-up tilt table testing

    Institute of Scientific and Technical Information of China (English)

    Hans-Joachim Gilfrich; Lena Marie Heidelmann; Franziska Grube; Hagen Frickmann; Sven Andreas Jungblut

    2015-01-01

    Background: Syncope is a relevant health problem in military environments. Reliable diagnosis is challenging. Tilt table testing is an important tool for syncope diagnosis. The aim of this study was to determine whether signs such as prodromal symptoms, co-morbidity, frequency of syncopal events, body length, body mass index, and electrocardiography (ECG) abnormalities can be used to predict the success of tilt table testing at diagnosing syncope. Methods: Data from 100 patients with histories of syncope or pre-syncope, who were diagnosed using head-up tilt table testing, were retrospectively analyzed in a cross-sectional analysis. The diagnostic procedure was based upon a modified version of the Westminster protocol without any pharmacological provocation. Results: Patients showing pathological reaction patterns during tilt table testing suffered from prodromal symptoms, such as dizziness and sweating, significantly more often. The patients reported more injuries resulting from syncopal events and more previous syncopal events, and the prevalence of co-morbidity was greater among patients presenting negative findings during tilt testing. An asthenic-leptosomal physique was not confirmed as a risk factor for syncopal events as is the case for idiopathic arterial hypotension. However, patients with pathological reaction patterns during tilt table testing were significantly taller. This finding was detected for both females and males. No significant predictors were found in the ECG patterns of patients showing syncope during tilt table testing. Conclusions: Frequency of prior syncope and prodromal symptoms, and increased body length with an otherwise good state of health influence the predictive value of tilt table testing for syncope diagnosis. In particular, if these factors are present, tilt table testing should be considered part of the diagnostic algorithm for soldiers with recurrent syncope.

  16. Reduced Sympathetic Response to Head-Up Tilt in Subjects with Mild Cognitive Impairment or Mild Alzheimer's Dementia

    Directory of Open Access Journals (Sweden)

    Marte Rognstad Mellingsæter

    2015-03-01

    Full Text Available Background: Hemodynamic control was compared in patients with mild cognitive impairment (MCI or mild Alzheimer's dementia (AD as well as in healthy elderly subjects. Methods: Noninvasive, continuous hemodynamic recordings were obtained from 14 patients and 48 controls during supine rest (tilt of 30 and 70°. Cardiac output, end-diastolic volume, total peripheral resistance, heart rate variability (HRV, systolic blood pressure variability (SBPV, and baroreceptor sensitivity were calculated. Results: At 70° tilt, the HRV indices differed significantly, with higher high-frequency (HF variability as well as lower low-frequency (LF variability and LF/HF ratios in the patients. The patients had significantly lower SBPV in the LF range at 30° tilt. Conclusions: The results indicate a poorer sympathetic response to orthostatic stress in MCI and mild AD.

  17. The effects of head-up and head-down tilt on central respiratory chemoreflex loop gain tested by hyperoxic rebreathing.

    Science.gov (United States)

    Skow, Rachel J; Tymko, Michael M; MacKay, Christina M; Steinback, Craig D; Day, Trevor A

    2014-01-01

    Central respiratory chemosensitivity is mediated via chemoreceptor neurons located throughout brain stem tissue. These receptors detect proximal CO2/[H(+)] (i.e., controller gain) and modulate breathing in a classic negative feedback loop. Loop gain (responsiveness) is the theoretical product of controller (chemoreceptors), mixing/feedback (cardiovascular and cerebrovascular systems), and plant (pulmonary system) gains. The level of chemoreceptor stimulation is determined by interactions between mixing and plant gains. The extent to which steady-state changes in body position may affect central chemoreflex loop gain in response to CO2 is unclear. Because of the potential effects of tilt on pulmonary mechanics, we hypothesized that plant gain would be altered by head-up and head-down tilt (HUT, HDT) during hyperoxic rebreathing, which theoretically isolates plant gain by eliminating systemic arterial-tissue gradients. Sixteen subjects (eight females) underwent hyperoxic rebreathing tests on a tilt table to quantify central chemoreflex loop gain in five steady-state positions: 90° HUT, 45° HUT, supine, 45° HDT, and 90° HDT. Respiratory responses (tidal volume, VT; frequency, fR; minute ventilation, VE) were quantified during steady-state and increases in CO2 during rebreathing by linear regression above the ventilatory recruitment threshold (VRT). Using one-factor analysis of variance, we found that there were no differences in the respiratory responses between the five positions (VRT, P=0.711; VT, P=0.290; fR, P=0.748; VE, P=0.325). Our findings suggest that during steady-state orthostatic stress, the ability of subjects to mount a normal ventilatory response to increased CO2 was unaffected, despite any potential changes in pulmonary mechanics associated with positional challenges.

  18. Hemodynamic response to exercise and head-up tilt of patients implanted with a rotary blood pump: a computational modeling study.

    Science.gov (United States)

    Lim, Einly; Salamonsen, Robert Francis; Mansouri, Mahdi; Gaddum, Nicholas; Mason, David Glen; Timms, Daniel L; Stevens, Michael Charles; Fraser, John; Akmeliawati, Rini; Lovell, Nigel Hamilton

    2015-02-01

    The present study investigates the response of implantable rotary blood pump (IRBP)-assisted patients to exercise and head-up tilt (HUT), as well as the effect of alterations in the model parameter values on this response, using validated numerical models. Furthermore, we comparatively evaluate the performance of a number of previously proposed physiologically responsive controllers, including constant speed, constant flow pulsatility index (PI), constant average pressure difference between the aorta and the left atrium, constant average differential pump pressure, constant ratio between mean pump flow and pump flow pulsatility (ratioP I or linear Starling-like control), as well as constant left atrial pressure ( P l a ¯ ) control, with regard to their ability to increase cardiac output during exercise while maintaining circulatory stability upon HUT. Although native cardiac output increases automatically during exercise, increasing pump speed was able to further improve total cardiac output and reduce elevated filling pressures. At the same time, reduced venous return associated with upright posture was not shown to induce left ventricular (LV) suction. Although P l a ¯ control outperformed other control modes in its ability to increase cardiac output during exercise, it caused a fall in the mean arterial pressure upon HUT, which may cause postural hypotension or patient discomfort. To the contrary, maintaining constant average pressure difference between the aorta and the left atrium demonstrated superior performance in both exercise and HUT scenarios. Due to their strong dependence on the pump operating point, PI and ratioPI control performed poorly during exercise and HUT. Our simulation results also highlighted the importance of the baroreflex mechanism in determining the response of the IRBP-assisted patients to exercise and postural changes, where desensitized reflex response attenuated the percentage increase in cardiac output during exercise and

  19. Orthostatic intolerance in 6 degrees head-down tilt and lower body negative pressure loading

    Science.gov (United States)

    Yajima, Kazuyoshi; Miyamoto, Akira; Ito, Masao; Mano, Takaichi; Nakayama, Kiyoshi

    6 degrees head-down tilt bed rest experiment for 6 days was conducted at Nihon University Itabashi Hospital for 10 male athletes. In order to observe the orthostatic intolerance due to six days head-down tilt bed rest, 70 degrees head up tilt tests were performed before and after the head-down tilt. Two types of orthostatic intolerance were distinguished by the time course of their cardiovascular responses. One was vagotonia type and the other was brain anemia type. The latter type was commonly seen among astronauts after space flight due to the lack of plasma volume. As this volume change is considered to be initiated by some fluid loss from the lower extremities, analysis was made to clarify the relation between the leg volume change and the types of orthostatic intolerance. Nakayama proposed a Heart Rate Controllability Index, which is calculated from the initiate leg volume change and heart rate increase in head up tilt, for an indicator of the orthostatic intolerability. The index was applied to the subjects of six days head-down tilt above mentioned. For the subjects who showed a sign of presyncopy, the index values were higher or lower than that of the rest subjects who showed no sign of presyncopy. In order to evaluate the validity of the index, another experiment was conducted to induce an orthostatic intolerance by a different way of loading. The same types of orthostatic intolerance were observed and the index value hit high in the brain anemia type of orthostatic intolerance, while the vagotonia type showed relatively lower values than the normal group.

  20. 直立倾斜试验在儿童晕厥诊断中的价值%Value of head-up tilt table test in the diagnosis of syncope in children

    Institute of Scientific and Technical Information of China (English)

    董湘玉; 王远飞

    2016-01-01

    Syncope is a common emergency condition,which can cause harmful danger to the physical and mental health,quality of living and learning of children.Even,syncope -related body traumatic injuries and anxiety and depression often occur in these children,and some have a high risk of sudden death.So,early diagnosis is of great sig-nificance.Head -up tilt table test is considered the gold standard for the diagnosis of syncope,it plays a significant role in diagnosis,differential diagnosis,treatment and evaluation of therapeutic effects.%晕厥是儿童时期常见急症,对儿童及青少年的身心健康、学习和生活质量造成极大影响,晕厥相关性躯体意外伤害、焦虑或抑郁等也常有发生,而且部分患儿有高度的猝死危险性,因此,尽早明确诊断意义重大。目前,直立倾斜试验被认为是诊断晕厥的金标准,对儿童晕厥的诊断、鉴别诊断、治疗依据及治疗效果评价有着不可替代的地位。

  1. Twenty-degree-tilt radiography for evaluation of lateral humeral condylar fracture in children

    Energy Technology Data Exchange (ETDEWEB)

    Imada, Hideaki; Tanaka, Ryuji; Itoh, Yohei; Kishi, Kazuhiko [National Hospital Organization, Higashi-Hiroshima Medical Center, Department of Orthopedic Surgery, Higashi Hiroshima, Hiroshima (Japan)

    2010-03-15

    To investigate the efficacy of '20 -tilt anteroposterior (A-P) radiography' in the assessment of lateral condylar fractures of the distal humerus. Eighteen children with lateral humeral condylar fractures were studied. Every child underwent conventional A-P and lateral radiography, and six children underwent multi-detector computed tomography (MDCT). For the investigation of 20 -tilt radiography, ten children with lateral humeral condylar fractures had conventional and 20 -tilt A-P and lateral radiography both preoperatively and postoperatively. Fragment dislocation was measured at the lateral and medial margins of the fracture on both the conventional A-P and 20 -tilt A-P radiographs. The lateral condylar fragment was triangular and was most prominent posteriorly. The fracture line was typically tilted approximately 20 to a reference line perpendicular to the long axis of the humerus in the lateral view. The extent of dislocation at the lateral and medial margins of the fracture site by 20 -tilt A-P radiography (9.3 {+-} 3.6 mm and 5.6 {+-} 2.5 mm) was significantly wider than that measured by the conventional method (6.8 {+-} 4.1 mm and 2.0 {+-} 1.5 mm), which may influence treatment. Twenty-degree-tilt A-P radiography may more precisely demonstrate fragment dislocation than standard radiographs and may influence patient treatment. (orig.)

  2. Effect of head-up tilt on cerebral blood flow velocity during general anesthesla in patients with diabetic neuropathy%头高位对糖尿病并发自主神经病变患者全麻下脑血流速度的影响

    Institute of Scientific and Technical Information of China (English)

    王宏伟; 钟泰迪

    2012-01-01

    目的 评价头高位对糖尿病并发自主神经病变患者全麻下脑血流速度的影响.方法 择期行全麻手术患者60例,ASA分级Ⅰ或Ⅱ级,年龄40~60岁,体重52 ~70 kg,按照合并糖尿病情况,将患者分为3组:非糖尿病患者对照组(C组)、无自主神经病变的糖尿病组(D组)和糖尿病并发自主神经病变组(ANS-D组),每组20例.全麻诱导气管插管后,于平卧位(T0)、头高位45.后1.5 min(T1)、3.5 min(T2)、5.5 min(T3)时记录MAP和大脑中动脉血流速度(MBFV).结果 与T0时相比,C组和D组T1,2时MAP,T1时MBFV降低,ANS-D组T1-3时MAP和MBFV降低(P<0.05),各组间比较MAP和MBFV差异无统计学意义(P>0.05).结论 头高位时非糖尿病、无自主神经病变的糖尿病患者和糖尿病并发自主神经病变患者全麻下脑血流速度均降低且无差别.%Objective To investigate the effect of head-up tilt on cerebral blood flow velocity during general anesthesia in patients with diabetic neuropathy.Methods Sixty ASA Ⅰ - Ⅱ patients of both sexes aged 40-60 yr weighing 52-70 kg undergoing general anesthesia were divided into 3 groups according to diseases complicated with diabetes situation ( n =20 each):group Ⅰ normal control the patients did not have diabetes mellitus; group Ⅱ type Ⅱ diabetics without neuropathy and group Ⅲ Ⅱ diabetics with neuropathy.Anesthesia was induced with propofol 2 mg/kg,fentanyl 3 μg/kg and vecuronium 0.1 mg/kg and maintained with 1% sevoflurane.The patients were intubated and mechanically ventilated.PErCO2 was maintained at 35-45 mm Hg.Transcranial doppler (TCD)was used to measure middle cerebral artery blood flow velocity (MBFV).MAP and MBFV were measured and recorded in supine position (baseline) and at 1.5,3.5 and 5.5 min of 45° head-up tilt.Results The 3 groups were comparable with respect to age,body weight,height and M/F sex ratio.MAP and MBFV significantly decreased at 45° head-up tilt as compared with the baseline in all

  3. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... this? Submit Button Connect with HEADS UP & CDC's Injury Center HEADS UP Resources File Formats Help: How ... Disease Control and Prevention , Â National Center for Injury Prevention and Control , Â Division of Unintentional Injury ...

  4. Time-dependent heart rate variability in the head-up tilt test in children with postural orthostatic tachycardia syndrome%儿童体位性心动过速综合征直立倾斜试验中时间依赖性的心率变化

    Institute of Scientific and Technical Information of China (English)

    冉静; 王成; 邹润梅; 吴礼嘉; 林萍; 李芳; 许毅

    2015-01-01

    ObjectiveTo study the time-dependent heart rate (HR) variability in the head-up tilt test (HUTT) in children with postural orthostatic tachycardia syndrome (POTS) and to explore the HR diagnostic criteria for POTS in children.MethodsA retrospective analysis was performed on the clinical data of 105 children diagnosed with POTS with HR ≥120 beats per minute (bpm) within the ifrst 10 minutes of HUTT between January 2007 and December 2014. Their HR variability within the first 10 minutes of HUTT was analyzed.ResultsThe HR of children with POTS increased gradually from the supine position to a 60° head-up tilt position, and the increase in HR was 24±12 bpm at the beginning of HUTT, 30±14 bpm at 3 minutes of HUTT, 32±13 bpm at 5 minutes of HUTT, and 38±12 bpm at 10 minutes of HUTT. The average maximal HR increase within the ifrst 10 minutes of HUTT was 43±10 bpm.ConclusionsIn children with POTS, the HR variability gradually increases with time, and therefore, it is suggested that HR increase ≥40 bpm is more suitable for diagnosis of POTS in children.%目的:分析体位性心动过速综合征(POTS)儿童在直立倾斜试验(HUTT)过程中时间依赖性的心率变化,探讨儿童POTS的心率诊断标准。方法回顾性研究2007年1月至2014年12月的HUTT 10 min内最大心率≥120次/min诊断为POTS儿童105例,分析其在HUTT 10 min内心率的变化。结果POTS儿童由平卧位变为倾斜60°体位时心率逐渐增加,在HUTT即刻心率增加24±12次/min,HUTT 后3 min心率增加30±14次/min,5 min时增加32±13次/min,10 min时增加38±12次/min。10 min内HUTT最大心率增加值平均为43±10次/min。结论POTS儿童HUTT 10 min内心率变化随时间延长而增加,建议儿童POTS诊断标准中心率增加≥40次/min较为适合。

  5. Exercise thermoregulation in men after 1 and 24-hours of 6 degrees head-down tilt

    Science.gov (United States)

    Ertl, A. C.; Dearborn, A. S.; Weidhofer, A. R.; Bernauer, E. M.; Greenleaf, J. E.

    2000-01-01

    BACKGROUND: Exercise thermoregulation is dependent on heat loss by increased skin blood flow (convective and conductive heat loss) and through enhanced sweating (evaporative heat loss). Reduction of plasma volume (PV), increased plasma osmolality, physical deconditioning, and duration of exposure to simulated and actual microgravity reduces the ability to thermoregulate during exercise. HYPOTHESIS: We hypothesized that 24 h of head down tilt (HDT24) would alter thermoregulatory responses to a submaximal exercise test and result in a higher exercise rectal temperature (Tre) when compared with exercise Tre after 1 h of head down tilt (HDT1). METHODS: Seven men (31+/-SD 6 yr, peak oxygen uptake (VpO2peak) of 44+/-6 ml x kg(-1) x min(-1)) were studied during 70 min of supine cycling at 58+/-SE 1.5% VO2peak at 22.0 degrees C Tdb and 47% rh. RESULTS: Relative to pre-tilt sitting chair rest data, HDT1 resulted in a 6.1+/-0.9% increase and HDT24 in a 4.3+/-2.3% decrease in PV (delta = 10.4% between experiments, pthermoregulation), the Tre offset could have been caused by the HDT-induced hypovolemia.

  6. Patient Specific Modeling of Head-Up Tilt

    DEFF Research Database (Denmark)

    Williams, Nakeya; Wright, Andrew; Mehlsen, Jesper;

    2014-01-01

    blood pressure. The model contains five compartments representing arteries and veins in the upper and lower body of the systemic circulation, as well as the left ventricle facilitating pumping of the heart. A physiologically based sub-model describes gravitational effects on pooling of blood during...

  7. Leg intravenous pressure during head-up tilt.

    NARCIS (Netherlands)

    Groothuis, J.T.; Poelkens, F.; Wouters, C.W.; Kooijman, M.; Hopman, M.T.E.

    2008-01-01

    Leg vascular resistance is calculated as the arterial-venous pressure gradient divided by blood flow. During orthostatic challenges it is assumed that the hydrostatic pressure contributes equally to leg arterial, as well as to leg venous pressure. Because of venous valves, one may question whether,

  8. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... in Spanish [Podcast: 1:27 minutes] Send a Health eCard Heads Up! Prevent Concussions Prevent Head Injuries ... in Spanish [Podcast: 1:27 minutes] Send a Health eCard Heads Up! Prevent Concussions Prevent Head Injuries ...

  9. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... minutes] Heads Up! [Podcast: 0:59 seconds]; in Spanish [Podcast: 1:27 minutes] Send a Health eCard ... minutes] Heads Up! [Podcast: 0:59 seconds]; in Spanish [Podcast: 1:27 minutes] Send a Health eCard ...

  10. Projection/Reflection Heads-up Display

    Data.gov (United States)

    National Aeronautics and Space Administration — To address the NASA need for an EVA information display device, Physical Optics Corporation (POC) proposes to develop a new Projection/Reflection Heads-up Display...

  11. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Email Address What's this? Submit What's this? Submit Button Concussion in Youth Sports Training course: This page ... Email Address What's this? Submit What's this? Submit Button Connect with HEADS UP & CDC's Injury Center HEADS ...

  12. Intracranial and Intraocular Pressure During Various Degrees of Head-Down Tilt.

    Science.gov (United States)

    Marshall-Goebel, Karina; Mulder, Edwin; Bershad, Eric; Laing, Charles; Eklund, Anders; Malm, Jan; Stern, Claudia; Rittweger, Jörn

    2017-01-01

    More than half of astronauts develop ophthalmic changes during long-duration spaceflight consistent with an abnormal intraocular and intracranial pressure (IOP, ICP) difference. The aim of our study was to assess IOP and ICP during head-down tilt (HDT) and the additive or attenuating effects of 1% CO2 and lower body negative pressure (LBNP). In Experiment I, IOP and ICP were measured in nine healthy subjects after 3.5 h HDT in five conditions: -6°, -12°, and -18° HDT, -12° with 1% CO2, and -12° with -20 mmHg LBNP. In Experiment II, IOP was measured in 16 healthy subjects after 5 min tilt at +12°, 0°, -6°, -12°, -18°, and -24°, with and without -40 mmHg LBNP. ICP was only found to increase from supine baseline during -18° HDT (9.2 ± 0.9 and 14.4 ± 1 mmHg, respectively), whereas IOP increased from 15.7 ± 0.3 mmHg at 0° to 17.9 ± 0.4 mmHg during -12° HDT and from 15.3 ± 0.4 mmHg at 0° to 18.7 ± 0.4 mmHg during -18° HDT. The addition of -20 mmHg LBNP or 1% CO2 had no further effects on ICP or IOP. However, the use of -40 mmHg LBNP during HDT lowered IOP back to baseline values, except at -24° HDT. A small, posterior intraocular-intracranial pressure difference (IOP > ICP) is maintained during HDT, and a sustained or further decreased difference may lead to structural changes in the eye in real and simulated microgravity.Marshall-Goebel K, Mulder E, Bershad E, Laing C, Eklund A, Malm J, Stern C, Rittweger J. Intracranial and intraocular pressure during various degrees of head-down tilt. Aerosp Med Hum Perform. 2017; 88(1):10-16.

  13. Back pain during 6 degrees head-down tilt approximates that during actual microgravity

    Science.gov (United States)

    Hutchinson, K. J.; Watenpaugh, D. E.; Murthy, G.; Convertino, V. A.; Hargens, A. R.

    1995-01-01

    Astronauts often experience back pain during spaceflight. Retrospectively, Wing et al. (14) found that during spaceflight, 14 of 19 Shuttle crewmembers experienced back pain, which they described as dull (62%), localized to the lower back (50%), and with an intensity of 2 on a 5-point scale. Further, the spine lengthens 4-7 cm in microgravity. Our objective was to compare back pain and spinal lengthening (body height increase) during simulated microgravity (6 degrees head-down tilt, HDT) with the same parameters during actual microgravity. Eight male subjects completed a modified McGill pain questionnaire with intensity graded from zero (no pain) to five (intense and incapacitating pain) each day at 7:00 pm during 2 d pre-HDT control, 16 d HDT, and 1 d post-HDT recovery periods. Also, the subjects' heights were measured each day while supine (control and recovery) and during HDT. Back pain increased from zero (pre-tilt control period) to 2.3 +/- 0.4 at days 1 to 3 of HDT, and was categorized as dull and/or burning pain in subjects' lower backs. Only 2 subjects reported any pain after day 9 of HDT and during recovery. Heights increased 2.1 +/- 0.5 cm by day 3 of HDT and remained at that level until the end of the HDT period. Although spinal lengthening in space is greater than that during HDT, the HDT model approximates the level, type, distribution, and time course of back pain associated with actual microgravity. In the HDT model, pain subsides in intensity when spinal lengthening stops.(ABSTRACT TRUNCATED AT 250 WORDS).

  14. Head-Up Displays and Attention Capture

    Science.gov (United States)

    Prinzel, Lawrence J., III; Risser, Matthew

    2004-01-01

    The primary role of head-up displays (HUDs) is to provide primary flight, navigation, and guidance information to the pilot in a forward field-of-view on a head-up transparent screen. Therefore, this theoretically allows for optimal control of an aircraft through the simultaneous scanning of both instrument data and the out-the-window scene. However, despite significant aviation safety benefits afforded by HUDs, a number of accidents have shown that their use does not come without costs. The human factors community has identified significant issues related to the pilot distribution of near and far domain attentional resources because of the compellingness of symbology elements on the HUD; a concern termed, attention or cognitive capture. The paper describes the phenomena of attention capture and presents a selected survey of the literature on the etiology and potential prescriptions.

  15. Holographic Combiners for Head-Up Displays

    Science.gov (United States)

    1977-10-01

    AFAL-TR-77 -110 S HOLOGRAPHIC COMBINERS FOR HEAD-UP DISPLAYS S Radar and Optics Division Environmental Research Institute of Michigan P.O. Box 8618...to 200. SECURITY CLASSIFICATION OF THIS PAGE(RWihen Data Entered) FOREWORD This report was prepared by the Radar and Optics Division of the...with fringes parallel to the surface......31 Figure 13. Raytrace through the F-4 HUD with a holographic combiner

  16. Changes in the arteriolar volume pulse of the finger during various degrees of tilt using near infra-red and red photoplethysmography.

    Science.gov (United States)

    Christ, F; Nehring, I; Abicht, J; Baranov, V; Kotov, A; Gartside, I; Gamble, J; Messmer, K

    1998-05-12

    1. Photoplethysmography is a widely used non invasive technique for the measurement of peripheral oxygen saturation. A more detailed analysis of the volume pulse (VP) can indicate alterations in peripheral vascular tone, due to sympathetic stimulation, stress, pain and temperature. - 2. In six healthy male volunteers we investigated changes in the VP resulting from vasoconstriction and vasodilatation induced by varies degrees of tilt. Subjects were subjected 0 degrees tilt followed by head down -8 degrees -15 degrees, -30 degrees -15 degrees, -8 degrees, 0 degrees, 15 degrees, 30 degrees , 70 degrees, 30 degrees, 15 degrees and 0 degrees. Each tilt stage was sustained for 15 minutes. Both VP - and haemodynamic changes were continuously recorded 30s before and then for 210 s after the imposition of each tilt step. We used a new computer driven soft and hardware for the analysis of the VP. 3. The VP signal was obtained with a sensor emitting 840 nm (NIR) and 640 nm (RED) light into finger tip with a sample rate of 128 Hz. All data was normalised to the initial mean value obtained at 0 degrees tilt. The signal strength parameters amplitude, and area under the curve and the first derivative of the amplitude (flux) as well as time discrete parameters, time of first maximum (Tmax), dicrote wave (Td), volume pulse decrease (Tdec) and fundamental arterial oscillation Tag = Td - Tmax were measured. 4. HR increased significantly during 30 degrees and 70 degrees tilt, but no change in the other hemodynamic parameters was observed. Amplitude, area under the curve and flux of both the Red and the NIR signal increased following head down tilt. A significant decrease of those parameters was found during foot down tilt. 5. No significant changes were found in the time discrete values, neither within each tilt step nor when compared to the initial mean value at 0 degrees tilt. 6. This study reveals that signal strength related parameters such as area under the curve, amplitude and

  17. Age, splanchnic vasoconstriction, and heat stress during tilting

    Science.gov (United States)

    Minson, C. T.; Wladkowski, S. L.; Pawelczyk, J. A.; Kenney, W. L.

    1999-01-01

    During upright tilting, blood is translocated to the dependent veins of the legs and compensatory circulatory adjustments are necessary to maintain arterial pressure. For examination of the effect of age on these responses, seven young (23 +/- 1 yr) and seven older (70 +/- 3 yr) men were head-up tilted to 60 degrees in a thermoneutral condition and during passive heating with water-perfused suits. Measurements included heart rate (HR), cardiac output (Qc; acetylene rebreathing technique), central venous pressure (CVP), blood pressures, forearm blood flow (venous occlusion plethysmography), splanchnic and renal blood flows (indocyanine green and p-aminohippurate clearance), and esophageal and mean skin temperatures. In response to tilting in the thermoneutral condition, CVP and stroke volume decreased to a greater extent in the young men, but HR increased more, such that the fall in Qc was similar between the two groups in the upright posture. The rise in splanchnic vascular resistance (SVR) was greater in the older men, but the young men increased forearm vascular resistance (FVR) to a greater extent than the older men. The fall in Qc during combined heat stress and tilting was greater in the young compared with older men. Only four of the young men versus six of the older men were able to finish the second tilt without becoming presyncopal. In summary, the older men relied on a greater increase in SVR to compensate for a reduced ability to constrict the skin and muscle circulations (as determined by changes in FVR) during head-up tilting.

  18. Changes of plasma intermedin during head-up tilt test in children with postural tachycardia syndrome and its significance%体位性心动过速综合征患儿直立倾斜试验中血浆中介素的变化及意义

    Institute of Scientific and Technical Information of China (English)

    李红霞; 廖莹; 憨贞慧; 王瑜丽; 刘平; 张清友; 蔺婧; 唐朝枢; 金红芳

    2015-01-01

    目的 探讨体位性心动过速综合征(POTS)患儿在直立倾斜试验(HUTT)中血浆中介素含量的变化.方法 选取2013年11月至2014年6月北京大学第一医院收治的29例POTS患儿为研究对象,男14例,女15例,平均年龄(12.4±3.1)岁;经体格检查和HUTT筛查的健康儿童32例为对照组,男17例,女15例,平均年龄(11.6±2.2)岁.采用无创连续血压监测仪连续实时监测心率及血压,并进行心电图检测,分析比较POTS组患儿和对照组儿童平卧位收缩压、平卧位舒张压、平卧位平均动脉压(MAP)、△MAP(直立位与平卧位MAP差)、平卧位心率及△HR(直立位与平卧位心率差).采用夹心免疫发光法测定血浆中介素含量,分别比较POTS组与对照组平卧位血浆中介素的含量及POTS组患儿平卧状态下与HUTT阳性反应时血浆中介素的含量.结果 POTS组患儿和对照组儿童相比,年龄、身高、体重、平卧位收缩压、平卧位舒张压、平卧位MAP、△MAP、平卧位心率差异均无统计学意义(P>0.05).POTS组△HR明显高于对照组,差异有统计学意义[(48±10)比(22±7)次/min,t=9.797,P<0.05].平卧状态下,POTS组患儿血浆中介素的含量明显低于对照组儿童[(497±61) ×10-6比(529±58) ×10-6 mg/L,t =2.117,P<0.05].HUTT阳性反应时,血浆中介素含量明显高于平卧位[(537±57)×10-6比(497±61)× 10-6mg/L,t=-2.464,P<0.05].POTS组患儿HUTT阳性反应时与平卧状态下血浆中介素含量的差值与△HR成正相关(r=0.435,P<0.05).结论 POTS患儿直立倾斜体位时心率增加值与其血浆中介素含量升高幅度有关,中介素可能参与POTS的发病过程.%Objective To explore possible mechanisms of postural tachycardia syndrome (POTS) by comparing plasma intermedin (IMD) during head-up tilt test (HUTT) in children with POTS.Method The study subjects were divided into two groups:POTS group and control group.The POTS group consisted of twenty-nine children (male 14

  19. Isokinetic and isometric strength-endurance after 6 hours of immersion and 6 degrees head-down tilt in men

    Science.gov (United States)

    Shaffer-Bailey, M.; Greenleaf, J. E.; Hutchinson, T. M.

    1996-01-01

    PURPOSE: To determine weight (water) loss levels for onset of muscular strength and endurance changes during deconditioning. METHODS: Seven men (27-40 yr) performed maximal shoulder-, knee-, and ankle-joint isometric (0 degree.s(-1) load) and isokinetic (60 degrees, 120 degrees, 180 degrees.s(-1) velocity) exercise tests during ambulatory control (AC), after 6 h of 6 degrees head-down tilt (HDT; dry-bulb temp. = 23.2 +/- SD 0.6 degrees C, relative humidity = 31.1+/- 11.1%) and after 6 h of 80 degrees foot-down head-out water immersion (WI; water temp. = 35.0 +/- SD 0.1 degree C) treatments. RESULTS: Weight (water) loss after HDT (1.10 +/- SE 0.14 kg, 1.4 +/- 0.2% body wt) and WI (1.54+/- 0.19 kg, 2.0 +/- 0.2% body wt) were not different, but urinary excretion with WI (1,354 +/- 142 ml.6 h(-1)) was 28% greater (p knee at 180 degrees.s(-1) for 30 s) was not different between AC and the WI or HDT treatments. Shoulder-, knee-, and ankle-joint strength was unchanged except for three knee-joint peak torques: AC torque (120 degrees.s(-1), 285 +/- 20 Nm) decreased to 268 +/- 21 Nm (delta = -6%, p torques (180 degrees.s(-1), 260 +/- 19 Nm) decreased to 236 +/- 15 Nm (delta = -9%, p joint strength and endurance decrements is more than 2% body weight (water) loss, while significant reduction in knee-joint muscular strength-endurance occurred only at moderate (120 degrees.s(-1) and lighter (180 degrees.s(-1)) loads with body weight loss of 1.4-2.0% following WI or HDT, respectively. These weight (water) losses and knee-joint strength decrements are somewhat less than the mean weight loss of 2.6% and knee-joint strength decrements of 6-20% of American astronauts after Skylab flights to 84 d.

  20. Six-Degree Head-Down Tilt Bed Rest: Forty Years of Development as a Physiological Analog for Weightlessness

    Science.gov (United States)

    Smith, Jeffrey D.; Cromwell, Ronita L.; Kundrot, Craig E.; Charles, John B.

    2011-01-01

    Early on, bed rest was recognized as a method for inducing many of the physiological changes experienced by spaceflight. Head-down tilt (HDT) bed rest was first introduced as an analog for spaceflight by a Soviet team led by Genin and Kakurin. Their study was performed in 1970 (at -4 degrees) and lasted for 30 days; results were reported in the Russian Journal of Space Biology (Kosmicheskaya Biol. 1972; 6(4): 26-28 & 45-109). The goal was to test physiological countermeasures for cosmonauts who would soon begin month-long missions to the Salyut space station. HDT was chosen to produce a similar sensation of blood flow to the head reported by Soyuz cosmonauts. Over the next decade, other tilt angles were studied and comparisons with spaceflight were made, showing that HDT greater than 4 degrees was superior to horizontal bed rest for modeling acute physiological changes observed in space; but, at higher angles, subjects experienced greater discomfort without clearly improving the physiological comparison to spaceflight. A joint study performed by US and Soviet investigators, in 1979, set the goal of standardization of baseline conditions and chose 6-degrees HDT. This effectively established 6-degree HDT bed rest as the internationally-preferred analog for weightlessness and, since 1990, nearly all further studies have been conducted at 6-degrees HDT. A thorough literature review (1970-2010) revealed 534 primary scientific journal articles which reported results from using HDT as a physiological analog for spaceflight. These studies have ranged from as little as 10 minutes to the longest duration of 370 days. Long-term studies lasting four weeks or more have resulted in over 170 primary research articles. Today, the 6-degree HDT model provides a consistent, thoroughly-tested, ground-based analog for spaceflight and allows the proper scientific controls for rigorous testing of physiological countermeasures; however, all models have their strengths and limits. The 6

  1. Intracranial blood flow measured with single photon emission computer tomography (SPECT) during transient -6 degrees head-down tilt.

    Science.gov (United States)

    Satake, H; Konishi, T; Kawashima, T; Matsunami, K; Uno, T; Imai, S; Yamada, H; Hirakawa, C

    1994-02-01

    Regional cerebral blood flow (CBF) during a transient head-down tilt of -6 degrees (-6 degrees HDT) was measured with single photon emission computer tomography (SPECT). CBF was measured and averaged for both sides of the brain areas; e.g., the bilateral anterior cerebral artery (bACA) area, the middle cerebral artery (bMCA) area, the posterior cerebral artery (bPCA) area, bilateral basal ganglia, and the cerebellum. Among these areas, a significant increase in CBF was observed in the basal ganglia and the cerebellum during -6 degrees HDT compared to pre-HDT. When CBF was measured separately in the left or right brain area, these significances disappeared, although a trend of increase or decrease was still observable. A trend of increase was observed in the left anterior cerebral artery (IACA) area, the right middle cerebral artery (rMCA) area, the right posterior cerebral artery (rPCA) area, the left and right basal ganglia, and the cerebellum. In rACA, IMCA and IPCA areas, a slight decrease in CBF was observed. At the same time, cardiac parameters were measured. Heart rate (HR), stroke volume (SV) and cardiac output (CO) did not change significantly, although SV slightly increased and HR slightly decreased during -6 degrees HDT.

  2. The 30 degree tilt position vs the 90 degree lateral and supine positions in reducing the incidence of non-blanching erythema in a hospital inpatient population: a randomised controlled trial.

    Science.gov (United States)

    Young, Trudie

    2004-07-01

    Manual repositioning of patients by nursing staff is a recognised technique for preventing pressure ulcer formation. The 30 degree tilt is a method of positioning patients that, in the laboratory setting, reduced the contact pressure between the patient and the support surface. A randomised controlled trial was used to examine the effects of the 30 degree tilt position in reducing the incidence of non-blanching erythema (i.e. established pressure damage) in a hospital inpatient population (n=23) when compared to the use of the 90 degree lateral and supine position (n=23). The primary outcome of the trial was the incidence of pressure damage, defined as non-blanching erythema. In this study no subject developed pressure damage that presented with visible breaks in the epidermis, but all damage was restricted to areas of non-blanching erythema (five of the 39 subjects who completed the study exhibited such injury). The main findings of this study were that patient positioning using the 30 degree tilt method did not reduce the incidence of pressure damage compared with either the 90 degree lateral or supine positions. This study also investigated the feasibility of using the 30 degree tilt position with medical inpatients; it found that 78% of subjects experienced difficulty in adopting and maintaining the position. This finding seriously questions the practicality of using the 30 degree tilt method with a predominantly ill population.

  3. Dissipation of the tilting degree of freedom in heavy-ion-induced fission from four-dimensional Langevin dynamics

    Science.gov (United States)

    Nadtochy, P. N.; Ryabov, E. G.; Cheredov, A. V.; Adeev, G. D.

    2016-10-01

    A stochastic approach based on four-dimensional Langevin fission dynamics is applied to the calculation of a wide set of experimental observables of excited compound nuclei from 199Pb to 248Cf formed in reactions induced by heavy ions. In the model under investigation, the tilting degree of freedom ( K coordinate) representing the projection of the total angular momentum onto the symmetry axis of the nucleus is taken into account in addition to three collective shape coordinates introduced on the basis of {c,h,α} parametrization. The evolution of the K coordinate is described by means of the Langevin equation in the overdamped regime. The friction tensor for the shape collective coordinates is calculated under the assumption of the modified version of the one-body dissipation mechanism, where the reduction coefficient ks of the contribution from the "wall" formula is introduced. The calculations are performed both for the constant values of the coefficient ks and for the coordinate-dependent reduction coefficient ks(q) which is found on the basis of the "chaos-weighted wall formula". Different possibilities of the deformation-dependent dissipation coefficient (γK) for the K coordinate are investigated. The presented results demonstrate that an impact of the ks and γK parameters on the calculated observable fission characteristics can be selectively probed. It was found that it is possible to describe the experimental data consistently with the deformation-dependent γK(q) coefficient for shapes featuring a neck, which predicts quite small values of γK=0.0077 (MeV zs)-1/2 and constant γK=0.1-0.4 (MeV zs)-1/2 for compact shapes featuring no neck.

  4. Improvement of Head-Up Display Standards. Volume 3. An Evaluation of Head-Up Display Safety.

    Science.gov (United States)

    1987-09-01

    result was the PERSEPOLIS display (21). These displays both make use of the fundamental relationship "I’. between ALPHA, GAMMA, and THETA and use air...designed to emphasize the unique relationship between THETA, GAMMA, and ALPHA. The Klopfstein and PERSEPOLIS HUDs, designed for transport airplanes made...CSF 21 H. Suisse, Head-Up Display System -- PERSEPOLIS Symbology, Dassault Report DGT-16433, September 1979 22 "A Word from the Navy," ALPA Head-Up

  5. 芯片偏置对散热器倾斜程度影响分析%Effect Analysis of Chip Offset on Heat Sink Tilt Degree

    Institute of Scientific and Technical Information of China (English)

    龚宝龙

    2015-01-01

    采用有限元分析方法,仿真分析多种芯片偏心位置及散热器倾斜状况,比较散热器倾斜程度,优化芯片最佳的偏置位置,为芯片摆放提供最优建议。通过不同芯片位置对散热器倾斜程度影响的分析,得出以下结论:芯片向正上方偏移时,散热器的倾斜程度与芯片偏置距离呈线性关系。故芯片偏置距离越小,散热器的倾斜程度越小;向上偏置一定距离后,还需再向左或向右偏置的话,都会增加散热器的倾斜程度;芯片斜置时,平衡芯片几何中心至2个固定孔的距离,使芯片至2个固定孔距离差最小,可使散热器倾斜程度最小。%By applying finite element analysis method,the effect of chip offset on heat sink tilt phenomenon is analyzed.The best offset location of chip was identified and some suggestions for chips were provided.According to the results,the following conclusions were drawn:when the chip offset is located directly above,the relationship be-tween tilt of heat sink and chip offset distance is linear.Thus,as the chip offset distance decreases, the tilt degree decreases.If the offset is moved up-ward a certain distance and if its direction is re-quired to be towards the left or towards the right, tilt of heat sink will increase.When the chip off-sets obliquely,minimizing the distance between chip and two fixed holes,the tilt degree of the heat sink tilt can be minimized.

  6. Impaired cerebral autoregulation during head up tilt in patients with severe brain injury

    DEFF Research Database (Denmark)

    Riberholt, Christian Gunge; Olesen, Niels Damkjær; Thing, Mira

    2016-01-01

    acquired brain injury and a low level of consciousness. Fourteen patients with severe acquired brain injury and orthostatic intolerance and fifteen healthy volunteers were enrolled. Blood pressure was evaluated by pulse contour analysis, heart rate and RR-intervals were determined by electrocardiography...

  7. The Changes of Heart Rate Power Spectral Density during Head-up Tilt Test

    Institute of Scientific and Technical Information of China (English)

    陈椿; 张馥敏; 黄元铸; 马文珠

    1998-01-01

    IntroductionHUThasgreatclinicalvalueforthediagno-sisofunexplainedsyncope[1,2].HRPSDanaysisisanew,sensitive,quantitativeandnon...

  8. Acute effects of head-down tilt and hypoxia on modulators of fluid homeostasis

    Science.gov (United States)

    Whitson, P. A.; Cintron, N. M.; Pietrzyk, R. A.; Scotto, P.; Loeppky, J. A.

    1994-01-01

    In an effort to understand the interaction between acute postural fluid shifts and hypoxia on hormonal regulation of fluid homeostasis, the authors measured the responses to head-down tilt with and without acute exposure to normobaric hypoxia. Plasma atrial natriuretic peptide (ANP), cyclic guanosine monophosphate (cGMP), cyclic adenosine monophosphate (cAMP), plasma aldosterone (ALD), and plasma renin activity (PRA) were measured in six healthy male volunteers who were exposed to a head-down tilt protocol during normoxia and hypoxia. The tilt protocol consisted of a 17 degrees head-up phase (30 minutes), a 28 degrees head-down phase (1 hour), and a 17 degrees head-up recovery period (2 hours, with the last hour normoxic in both experiments). Altitude equivalent to 14,828 ft was simulated by having the subjects breathe an inspired gas mixture with 13.9% oxygen. The results indicate that the postural fluid redistribution associated with a 60-minute head-down tilt induces the release of ANP and cGMP during both hypoxia and normoxia. Hypoxia increased cGMP, cAMP, ALD, and PRA throughout the protocol and significantly potentiated the increase in cGMP during head-down tilt. Hypoxia had no overall effect on the release of ANP, but appeared to attenuate the increase with head-down tilt. This study describes the acute effects of hypoxia on the endocrine response during fluid redistribution and suggests that the magnitude, but not the direction, of these changes with posture is affected by hypoxia.

  9. Heads Up! Play it Safe When it Comes to Concussions

    Centers for Disease Control (CDC) Podcasts

    2007-05-21

    As many as 3.8 million sports- and recreation-related concussions are estimated to occur in the United States each year. This podcast is a radio interview with CDC's Dr. Julie Gilchrist on the newly available “Heads Up: Concussion in Youth Sports" tool kit, which was developed to provide information to coaches, parents, and athletes involved in youth sports on preventing, recognizing, and responding to a concussion.  Created: 5/21/2007 by National Center for Injury Prevention and Control, Division of Injury Response.   Date Released: 10/31/2007.

  10. Effect of tilting on oxygenation in newborn infants.

    OpenAIRE

    Thoresen, M; Cowan, F.; Whitelaw, A

    1988-01-01

    Transcutaneous (tc) PO2 in newborn infants increased on head up tilting (median increase 0.5 kPa at term, 1.0 kPa preterm). Head down tilting was associated with an equivalent fall in tcPO2. There was no change in tcPCO2. Tilting of infants mechanically ventilated for respiratory distress syndrome or surgery produced no consistent change in PO2.

  11. Influence of passive leg movements on blood circulation on the tilt table in healthy adults

    Directory of Open Access Journals (Sweden)

    Czell David

    2004-10-01

    Full Text Available Abstract Background One problem in the mobilization of patients with neurological diseases, such as spinal cord injury, is the circulatory collapse that occurs while changing from supine to vertical position because of the missing venous pump due to paralyzed leg muscles. Therefore, a tilt table with integrated stepping device (tilt stepper was developed, which allows passive stepping movements for performing locomotion training in an early state of rehabilitation. The aim of this pilot study was to investigate if passive stepping and cycling movements of the legs during tilt table training could stabilize blood circulation and prevent neurally-mediated syncope in healthy young adults. Methods In the first experiment, healthy subjects were tested on a traditional tilt table. Subjects who had a syncope or near-syncope in this condition underwent a second trial on the tilt stepper. In the second experiment, a group of healthy subjects was investigated on a traditional tilt table, the second group on the tilt ergometer, a device that allows cycling movements during tilt table training. We used the chi-square test to compare the occurrence of near-syncope/syncope in both groups (tilt table/tilt stepper and tilt table/tilt ergometer and ANOVA to compare the blood pressure and heart rate between the groups at the four time intervals (supine, at 2 minutes, at 6 minutes and end of head-up tilt. Results Separate chi-square tests performed for each experiment showed significant differences in the occurrence of near syncope or syncope based on the device used. Comparison of the two groups (tilt stepper/ tilt table in experiment one (ANOVA showed that blood pressure was significantly higher at the end of head-up tilt on the tilt stepper and on the tilt table there was a greater increase in heart rate (2 minutes after head-up tilt. Comparison of the two groups (tilt ergometer/tilt table in experiment 2 (ANOVA showed that blood pressure was significantly

  12. Microlens array-based high-gain screen design for direct projection head-up displays.

    Science.gov (United States)

    Hedili, M Kivanc; Freeman, Mark O; Urey, Hakan

    2013-02-20

    Head-up display (HUD) systems have been used in recent car models to provide essential information to the drivers while keeping their eyes on the road. Virtual image HUD systems have been the preferred method, but they have the drawback of requiring a large volume of space in order to accommodate the relay optics that creates the virtual image. This is especially significant as the desired field of view increases. Direct projection HUD systems have been developed with a separate stand-alone microlens array (MLA)-based transparent screen on the dashboard, offering a compact solution. In this paper, we propose a direct projection HUD system based on a unique, windshield-embedded see-through screen that uses minimal space under the dashboard, offering an elegant and compact solution to the HUD problem. The screen is based on MLAs with varying surface normal angles such that the light from the projector is directed to the viewer's eyes from all positions across the field of view. Varying tilts provide an efficient relay and high brightness even with a low-lumen output projector. The calculated screen gain is about 69 and the eyebox area is about 30 cm×30 cm.

  13. Reduce volume of head-up display by image stitching

    Science.gov (United States)

    Chiu, Yi-Feng; Su, Guo-Dung J.

    2016-09-01

    Head-up Display (HUD) is a safety feature for automobile drivers. Although there have been some HUD systems in commercial product already, their images are too small to show assistance information. Another problem, the volume of HUD is too large. We proposed a HUD including micro-projectors, rear-projection screen, microlens array (MLA) and the light source is 28 mm x 14 mm realized a 200 mm x 100 mm image in 3 meters from drivers. We want to use the MLA to reduce the volume by virtual image stitching. We design the HUD's package dimensions is 12 cm x 12 cm x 9 cm. It is able to show speed, map-navigation and night vision information. We used Liquid Crystal Display (LCD) as our image source due to its brighter image output required and the minimum volume occupancy. The MLA is a multi aperture system. The proposed MLA consists of many optical channels each transmitting a segment of the whole field of view. The design of the system provides the stitching of the partial images, so that we can see the whole virtual image.

  14. A comparison of autonomic responses in humans induced by two simulation models of weightlessness: lower body positive pressure and 6 degrees head-down tilt.

    Science.gov (United States)

    Fu, Q; Sugiyama, Y; Kamiya, A; Mano, T

    2000-04-12

    Six-degree head-down tilt (HDT) is well accepted as an effective weightlessness model in humans. However, some researchers utilized lower body positive pressure (LBPP) to simulate the cardiovascular and renal effects of a decreased gravitational stress. In order to determine whether LBPP was a suitable model for simulated weightlessness, we compared the differences between these two methods. Ten healthy males, aged 21-41 years, were subjected to graded LBPP at 10, 20 and 30 mmHg, as well as 6 degrees HDT. Muscle sympathetic nerve activity (MSNA) was microneurographically recorded from the tibial nerve along with cardiovascular variables. We found that MSNA decreased by 27% to a similar extent both at low levels of LBPP (10 and 20 mmHg) and HDT. However, at a high level of LBPP (30 mmHg), MSNA tended to increase. Mean arterial pressure was elevated significantly by 11% (10 mmHg) at 30 mmHg LBPP, but remained unchanged at low levels of LBPP and HDT. Heart rate did not change during the entire LBPP and HDT procedures. Total peripheral resistance markedly increased by 36% at 30 mmHg LBPP, but decreased by 9% at HDT. Both stroke volume and cardiac output tended to decrease at 30 mmHg LBPP, but increased at HDT. These results suggest that although both LBPP and HDT induce fluid shifts from the lower body toward the thoracic compartment, autonomic responses are different, especially at LBPP greater than 20 mmHg. We note that high levels of LBPP (>20 mmHg) activate not only cardiopulmonary and arterial baroreflexes, but also intramuscular mechanoreflexes, while 6 degrees HDT only activates cardiopulmonary baroreflexes. We conclude that LBPP is not a suitable model for simulated weightlessness in humans.

  15. Head Tilt

    Science.gov (United States)

    ... Healthy Living Healthy Living Healthy Living Nutrition Fitness Sports Oral Health Emotional Wellness Growing Healthy Sleep Safety & ... When this happens, the neck muscles go into spasm, causing the head to tilt to one side. ...

  16. Graded vascular autonomic control versus discontinuous cardiac control during gradual upright tilt.

    Science.gov (United States)

    Bahjaoui-Bouhaddi, M; Cappelle, S; Henriet, M T; Dumoulin, G; Wolf, J P; Regnard, J

    2000-03-15

    Indexes of heart rate variability (HRV) and the slope of cardiac baroreflex are extensively used for non invasive assessment of circulatory autonomic control in pathophysiology. We performed this study (1) to assess the sensitivity of these indexes towards small graded postural stimulations and (2) to delineate the informations provided about the settings of both vascular tone and cardiac activity. Twenty healthy subjects were randomly tilted for eight minutes at each of the six angles: -10 degrees, 0 degrees (supine), 10 degrees, 30 degrees, 45 degrees, and 60 degrees. Instant RR-interval and finger blood pressure (BP) were continuously recorded, and venous blood was collected at the end of each 8 min position for catecholamines determination. Group average heart rate, noradrenaline and diastolic BP (DBP) increased linearly with head-up tilt angle from 10 degrees. Systolic BP (SBB) ranked only two distinct series -10 degrees, 0 degrees, 10 degrees versus 30 degrees, 45 degrees, 60 degrees, as did the number of spontaneous baroreflex (SBR) sequences. The spectral power of the low-frequency (LF) and high-frequency (HF) of RR variability and the ratio LF/HF changed rather abruptly from either 30 degrees or 45 degrees, depending on each individual. Both HF/tot i.e. the ratio of HF to total spectral RR variability and the slope of SBR decreased markedly from 10 degrees to 30 degrees and less but more gradually from 30 degrees to 60 degrees. Thus, our observations argue for gradual adjustments of vascular tone as reflected by highly consistent changes in plasma noradrenaline and diastolic arterial pressure, contrasting with a main discontinuous autonomic setting of cardiac activity as reflected by changes in the harmonic components of spectral RR variability and in the slope of cardiac baroreflex. The pattern of changes in systolic arterial pressure attested the discontinuous cardiac autonomic control rather than the gradual setting of arterial tone. We submit that

  17. Sensitivity and specificity of the tilt table test in young patients with unexplained syncope.

    Science.gov (United States)

    Fouad, F M; Sitthisook, S; Vanerio, G; Maloney, J; Okabe, M; Jaeger, F; Schluchter, M; Maloney, J D

    1993-03-01

    The usefulness of the head-up tilt testing (HUT) has been previously addressed in diagnosing vasovagal neuroregulatory syncope in the teenage population. However, data concerning sensitivity and specificity is deficient due to the lack of control groups. We compared the response to HUT in young patients referred because of syncope or near syncope (n = 44, mean age 16 +/- 3 years SD) to healthy young volunteers with a normal physical examination and no previous history of syncope (n = 18, mean age 16 +/- 2 years) and to determine the sensitivity and specificity of HUT. The graded tilt protocol was performed at 15 degrees, 30 degrees, and 45 degrees (each for 2 min), and then 60 degrees for 20 minutes. Cuff blood pressure was measured every minute and lead II ECG was continuously monitored. 25 of the 44 patients (57%) developed a vasovagal response or became symptomatic after 13.8 +/- 5.7 minutes of HUT. Three of the 18 volunteers (17%) had a vasovagal response and became symptomatic after 9 +/- 3 minutes of HUT. There was no statistical difference among the four groups (with and without tilt induced vasovagal response) in terms of age and baseline hemodynamic data. The sensitivity of 20 minutes HUT was 57% and its specificity was 83%. The presyncopal hemodynamic response in patients with history of syncope that was characterized by a significant decrease in systolic blood pressure and lack of increase of diastolic blood pressure as compared with baseline and with other groups.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Prueba de inclinación (“Head-up Tilt Test”), lecciones aprendidas en 564 casos consecutivos: Lessons Learned from 564 Consecutive Cases Head-Up Tilt Test

    OpenAIRE

    Oswaldo Gutiérrez-Sotelo; Yorleny Alfaro-Badilla

    2012-01-01

    Introducción. El síncope es un motivo frecuente de consulta; el mecanismo causal más común es el reflejo, que incluye el síncope neurocardiogénico (SN), la hipotensión ortostática, la hipersensibilidad del seno carotídeo, entre otros. Estas variantes se valoran mediante la prueba de inclinación, con o sin estímulo farmacológico con nitroglicerina. El presente estudio recoge la experiencia con este examen auxiliar realizado en nuestro centro en los últimos 8 años. Material y métodos. Es un est...

  19. Using Kalman filtering to predict time-varying parameters in a model predicting baroreflex regulation during head-up tilt

    DEFF Research Database (Denmark)

    Matzuka, Brett; Mehlsen, Jesper; Tran, Hien

    2015-01-01

    , while the second uses the ensemble transform Kalman filter (ETKF) [1], [12], [13], [35]. In addition, we show that the delayed rejection adaptive Metropolis (DRAM) algorithm can be used for predicting parameter uncertainties within the spline methodology, which is compared with the variability obtained...

  20. Stroke volume of the heart and thoracic fluid content during head-up and head-down tilt in humans

    DEFF Research Database (Denmark)

    van Lieshout, J J; Harms, M P M; Pott, F

    2005-01-01

    The stroke volume (SV) of the heart depends on the diastolic volume but, for the intact organism, central pressures are applied widely to express the filling of the heart.......The stroke volume (SV) of the heart depends on the diastolic volume but, for the intact organism, central pressures are applied widely to express the filling of the heart....

  1. Changes in endotracheal tube cuff pressure during laparoscopic surgery in head-up or head-down position

    Science.gov (United States)

    2014-01-01

    Background The abdominal insufflation and surgical positioning in the laparoscopic surgery have been reported to result in an increase of airway pressure. However, associated effects on changes of endotracheal tube cuff pressure are not well established. Methods 70 patients undergoing elective laparoscopic colorectal tumor resection (head-down position, n = 38) and laparoscopic cholecystecomy (head-up position, n = 32) were enrolled and were compared to 15 patients undergoing elective open abdominal surgery. Changes of cuff and airway pressures before and after abdominal insufflation in supine position and after head-down or head-up positioning were analysed and compared. Results There was no significant cuff and airway pressure changes during the first fifteen minutes in open abdominal surgery. After insufflation, the cuff pressure increased from 26 ± 3 to 32 ± 6 and 27 ± 3 to 33 ± 5 cmH2O in patients receiving laparoscopic cholecystecomy and laparoscopic colorectal tumor resection respectively (both p < 0.001). The head-down tilt further increased cuff pressure from 33 ± 5 to 35 ± 5 cmH2O (p < 0.001). There six patients undergoing colorectal tumor resection (18.8%) and eight patients undergoing cholecystecomy (21.1%) had a total increase of cuff pressure more than 10 cm H2O (18.8%). There was no significant correlation between increase of cuff pressure and either the patient's body mass index or the common range of intra-abdominal pressure (10-15 mmHg) used in laparoscopic surgery. Conclusions An increase of endotracheal tube cuff pressure may occur during laparoscopic surgery especially in the head-down position. PMID:25210501

  2. Navigational Heads-Up Display: Will a Shipboard Augmented Electronic Navigation System Sink or Swim?

    Science.gov (United States)

    2015-03-01

    76 Table 6. Subject Video Game Practice...Interface GPS Global Positioning System HMD Head-Mounted Display HUD Heads-Up Display IP Internet Protocol IR Infrared LCD Liquid-Crystal Display...Stress Disorder SDK Software Development Kit SOG Speed over Ground SWOS Surface Warfare Officer School USD United States Dollar USNS United States

  3. The Impact of Reverse Trendelenburg Versus Head-up Position on Intraoperative Bleeding of Elective Rhinoplasty

    Science.gov (United States)

    Nooraei, Navid; Dabbagh, Ali; Niazi, Feizolah; Mohammadi, Siamak; Mohajerani, Seyed Amir; Radmand, Golnar; Hashemian, Seyed Mohammad Reza

    2013-01-01

    Background: In spite of several efforts for decreasing blood loss, our experience sometimes shows that some patients bleed more profusely during rhinoplasty. Patient position could have deep impact on bleeding amount during surgical procedures. Objective: In this study, we aimed to compare reverse trendelenburg position and head-up position on intra-operative bleeding of elective rhinoplasty. This was to check the effects of reverse trendelenburg position and head up position on the intraoperative bleeding of elective rhinoplasty. Methods: In this study, 30 ASA I (American Society of Anesthesiology physical condition classification) patients between 18 and 40 years of age who were candidate to rhinoplasty operations for first time were included. Patients were randomly assigned to reverse trendelenburg or head-up position. Exclusion criteria was any history or lab indicating coagulation problems or using any drug. All gauzes used and the blood that accumulated in the aspirator throughout the operation were calculated. Results: Our results showed that the mean amount of blood loss in reverse trendelenburg was lower (77.00 ± 13.20 ml) than head-up position (83.33 ± 21.18 ml), although, there was no statistical difference between two groups. However, there was no significant differences among two groups in different aspects of hemodynamic determinants and bleeding amount during and after rhinoplasty. Conclusions: Our results showed that patient bleeding is not increased because of positioning per se. In conclusion, perhaps in the future reverse trendelenburg will be given more often during rhinoplasry. PMID:24498500

  4. The impact of reverse trendelenburg versus head-up position on intraoperative bleeding of elective rhinoplasty

    Directory of Open Access Journals (Sweden)

    Navid Nooraei

    2013-01-01

    Full Text Available Background: In spite of several efforts for decreasing blood loss, our experience sometimes shows that some patients bleed more profusely during rhinoplasty. Patient position could have deep impact on bleeding amount during surgical procedures. Objective: In this study, we aimed to compare reverse trendelenburg position and head-up position on intra-operative bleeding of elective rhinoplasty. This was to check the effects of reverse trendelenburg position and head up position on the intraoperative bleeding of elective rhinoplasty. Methods: In this study, 30 ASA I (American Society of Anesthesiology physical condition classification patients between 18 and 40 years of age who were candidate to rhinoplasty operations for first time were included. Patients were randomly assigned to reverse trendelenburg or head-up position. Exclusion criteria was any history or lab indicating coagulation problems or using any drug. All gauzes used and the blood that accumulated in the aspirator throughout the operation were calculated. Results: Our results showed that the mean amount of blood loss in reverse trendelenburg was lower (77.00 ΁ 13.20 ml than head-up position (83.33 ΁ 21.18 ml, although, there was no statistical difference between two groups. However, there was no significant differences among two groups in different aspects of hemodynamic determinants and bleeding amount during and after rhinoplasty. Conclusions: Our results showed that patient bleeding is not increased because of positioning per se. In conclusion, perhaps in the future reverse trendelenburg will be given more often during rhinoplasry.

  5. A Comparison of Head-Up and Head-Down Display Formats during Instrument Flying Tasks

    Science.gov (United States)

    1992-11-01

    the fbllow-on flight test phase of the validation process. 74 UEICT TEO MS Is, NUMNER OF PA GES Simulation, Head-Up Display, Symbology, Instrument...standard was configured to the F-16C Multi-National Staged drafted to govern the development and validation of Improvement Programn ( MSIP ) Block 30 design...to increases in airspeed were to be conducted at the individual data trials. discretion of the pilot. PMfW Tf , Ms . Upon arrival, each pilot

  6. Analysis of tilt of the Günther Tulip filter.

    Science.gov (United States)

    Sag, Alan A; Stavas, Joseph M; Burke, Charles T; Dixon, Robert G; Marquess, Joel S; Mauro, Matthew A

    2008-05-01

    To determine the frequency, dimensions, predictors, and sequelae of Günther Tulip filter (GTF) tilt measured at the time of intended retrieval. Retrospective review of all medical records and posteroanterior cavograms of 175 patients who underwent both placement and retrieval of the GTF between August 2003 and July 2007 was performed to assess the frequency, dimensions, predictors, and sequelae of tilt. Tilt occurred at the first retrieval attempt in 159 of the 175 patients (91%). The average degree of tilt was 7.1 degrees (range, 0 degrees-30 degrees), with 87 of the 159 filters with tilt (55%) having a rightward tilt. Compared with the femoral approach, filters placed with a jugular approach demonstrated 4.2 degrees (range of the standard deviation, 3.1 degrees-5.3 degrees) greater tilt at the first retrieval attempt (95% confidence interval=2.6 degrees, 5.7 degrees; P<.001, two-sided Student t test), a greater frequency of tilt of at least 14 degrees (P=.002, two-sided Fisher exact test), and greater rightward tilt predominance (P=.046, one-sided Fisher exact test). Tilt magnitude at the first retrieval attempt correlated positively with the inferior vena cava diameter 40 mm caudal to the renal vein confluence (R=.183, P=.018, Pearson correlation). Within its limitations, this study detected no new cases of pulmonary embolism, caval perforation, or GTF migration. The success rates at the first attempt at retrieval and the cumulative GTF retrieval success rates were 93% (176 of 190 filters) and 97% (181 of 190 filters), respectively. All 29 GTFs with tilt of at least 14 degrees were placed and successfully retrieved by means of a jugular approach with minimal clinical and technical sequelae. Frequent GTF tilt detected at the first retrieval attempt can reach at least 14 degrees and is associated with minimal sequelae. Insertion approach and caval diameter are significant factors in GTF tilt.

  7. Simplified tilt table test protocol with continuous upright position during medication administration and no hydration.

    Science.gov (United States)

    Fisher, John D; Kim, Soo G; Ferrick, Kevin J; Gross, Jay N; Palma, Eugen C; Scavin, Gale M

    2003-01-01

    Recommendations for head-up tilt testing (HUT) often include the prolonged abstaining from food and water consumption (nothing by mouth [NPO]) and intravenous fluids administration before HUT. After the baseline test, supine equilibration periods are recommended before and between each dose of medication. The aim of this study was to determine if similar results are obtainable with a simpler protocol. After 2-3 hours NPO, 1,540 HUTs were performed at 70 degrees for 30 minutes unless predetermined endpoints were reached. Then, with the patient remaining in the tilted position, isoproterenol (ISO) (1 microgram/min), titrated every 3 minutes to a maximum of 5 micrograms/min (n = 803 patients), sublingual nitroglycerin (NTG) (300-400 micrograms) (n = 143 patients), or edrophonium (EDP) (5 mg) repeated once after 3 minutes (n = 46 patients) were administered. No aspiration or other adverse effects attributable to the abbreviated fasting period were observed. ISO was well tolerated as doses were increased. Vasovagal manifestations developed in 31% of ISO tests, in 11% with EDP, and in 50% with NTG (P postural changes during HUTs may be avoided when ISO is administered. With NTG the response may be excessive.

  8. Advances and trends of head-up and head-down display systems in automobiles

    Science.gov (United States)

    Betancur, J. Alejandro; Osorio-Gomez, Gilberto; Agudelo, J. David

    2014-06-01

    Currently, in the automotive industry the interaction between drivers and Augmented Reality (AR) systems is a subject of analysis, especially the identification of advantages and risks that this kind of interaction represents. Consequently, this paper attempts to put in evidence the potential applications of Head-Up (Display (HUD) and Head-Down Display (HDD) systems in automotive vehicles, showing applications and trends under study. In general, automotive advances related to AR devices suggest the partial integration of the HUD and HDD in automobiles; however, the right way to do it is still a moot point.

  9. High-resolution LCD projector for extra-wide-field-of-view head-up display

    Science.gov (United States)

    Brown, Robert D.; Modro, David H.; Quast, Gerhardt A.; Wood, Robert B.

    2003-09-01

    LCD projection-based cockpit displays are beginning to make entry into military and commercial aircraft. Customers for commercial Head-Up Displays (HUDs)(including airframe manufacturers) are now interested in the adaptation of the technology into existing and future HUD optical systems. LCD projection can improve mean-time-between-failure rates because the LCDs are very robust and the light sources can be replaced with scheduled maintenance by the customer without the need for re-calibration. LCD projectors promise to lower the cost of the HUD because the cost of these displays continues to drop while the cost of CRTs remain stable. LCD projectors provide the potential for multi-colors, higher brightness raster, and all-digital communication between the flight computer and display unit. Another potential benefit of LCD projection is the ability to increase field of view and viewing eyebox without exceeding existing power budgets or reducing display lifetime and reliability compared to the capabilities provided by CRTs today. This paper describes the performance requirements and improved performance of a third-generation LCD projection image source for use in a wide field of view head-up display (HUD) optical system. This paper will focus on new HUD requirements and the application of various technologies such as LCOS microdisplays, arc lamps, and rear-projection screens. Measured performance results are compared to the design requirements.

  10. Effects of exercise-heat acclimation on fluid, electrolyte, and endocrine responses during tilt and +Gz acceleration in women and men.

    Science.gov (United States)

    Greenleaf, J E; Brock, P J; Sciaraffa, D; Polese, A; Elizondo, R

    1985-07-01

    Plasma fluid, electrolyte, protein, renin, and vasoactive hormone (epinephrine, norepinephrine, vasopressin) responses were measured in six women (21-23 yr) and four men (21-38 yr) before and immediately following an orthostatic tolerance test (70 degrees head-up tilt) and a +Gz (head-to-foot) acceleration tolerance test (0.5 G X min-1 linear ramp to grayout). These tests were conducted before and after 12 consecutive days of exercise-heat acclimation when the subjects exercised on a cycle ergometer at a relative oxygen uptake of 44% to 49% peak oxygen uptake in a hot environment (Ta = 40 degrees C, 42% rh). During acclimation plasma volume increased by 10.6% (p less than 0.05) in the women and by 11.9% (p less than 0.05) in the men; in both groups exercise heart rate decreased significantly. After acclimation, acceleration tolerance was unchanged in both groups (range 3.1 to 3.4 G); the women's tilt tolerance was unchanged (range 33.6 to 39.5 min), but the men's tilt tolerance increased from 30.4 min before to 58.3 min (delta = 91%, p less than 0.05) after acclimation. Since the pattern of fluid, electrolyte, and protein shifts and acceleration tolerances in the women and men were virtually the same, the hormone responses were highly variable, and the men's tilt tolerance increased significantly after acclimation, it is clear that responses to tilting cannot be used to predict responses to acceleration. Analysis of data from the present study and the literature suggests that current exercise training regimes should be unrestricted for astronauts who have not previously been highly endurance trained.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. High brightness MEMS mirror based head-up display (HUD) modules with wireless data streaming capability

    Science.gov (United States)

    Milanovic, Veljko; Kasturi, Abhishek; Hachtel, Volker

    2015-02-01

    A high brightness Head-Up Display (HUD) module was demonstrated with a fast, dual-axis MEMS mirror that displays vector images and text, utilizing its ~8kHz bandwidth on both axes. Two methodologies were evaluated: in one, the mirror steers a laser at wide angles of phone applications is demonstrated, utilizing the mobile device both for content generation based on various messages or data, and for content streaming to the MEMS controller via Bluetooth interface. The display unit is highly resistant to vibrations and shock, and requires only ~1.5W to operate, even with content readable in sunlit outdoor conditions. The low power requirement is in part due to a vector graphics approach, allowing the efficient use of laser power, and also due to the use of a single, relatively high efficiency laser and simple optics.

  12. A head-up display for mid-air drone recovery

    Science.gov (United States)

    Augustine, W. L.; Heft, E. L.; Bowen, T. E.; Newman, R. L.

    1978-01-01

    During mid-air retrieval of parachute packages, the absence of a natural horizon creates serious difficulties for the pilot of the recovery helicopter. A head-up display (HUD) was tested in an attempt to solve this problem. Both a roll-stabilized HUD and a no-roll (pitch only) HUD were tested. The results show that fewer missed passes occurred with the roll-stabilized HUD when the horizon was obscured. The pilots also reported that the workload was greatly reduced. Roll-stabilization was required to prevent vertigo when flying in the absence of a natural horizon. Any HUD intended for mid-air retrieval should display pitch, roll, sideslip, airspeed, and vertical velocity.

  13. Computer science. Heads-up limit hold'em poker is solved.

    Science.gov (United States)

    Bowling, Michael; Burch, Neil; Johanson, Michael; Tammelin, Oskari

    2015-01-09

    Poker is a family of games that exhibit imperfect information, where players do not have full knowledge of past events. Whereas many perfect-information games have been solved (e.g., Connect Four and checkers), no nontrivial imperfect-information game played competitively by humans has previously been solved. Here, we announce that heads-up limit Texas hold'em is now essentially weakly solved. Furthermore, this computation formally proves the common wisdom that the dealer in the game holds a substantial advantage. This result was enabled by a new algorithm, CFR(+), which is capable of solving extensive-form games orders of magnitude larger than previously possible. Copyright © 2015, American Association for the Advancement of Science.

  14. Integration of Head-Up Display system in automotive industry: a generalized application

    Science.gov (United States)

    Betancur, J. Alejandro; Osorio, Gilberto; Mejía, Alejandro

    2013-06-01

    Throughout the development of the automotive industry, supporting activities related with driving has been material of analysis and experimentation, always seeking new ways to achieve greater safety for the driver and passengers. With the purpose of contributing to this topic, in order to contribute to this subject, this paper summarizes from past research experiences the use of Head-Up Display systems applied to the automobile industry, covering it from two main points of discussion: the first one, from a technical point of view, in which the main principles of optical design associated with a moderate-cost experimental set up are brought out; and the second one, an operational approach where an applied driving graphical interface is presented. Up to now, the results suggest that the experimental set up here discussed could be adaptable to any automobile vehicle, but it is needed further research and investment.

  15. DeepStack: Expert-level artificial intelligence in heads-up no-limit poker.

    Science.gov (United States)

    Moravčík, Matej; Schmid, Martin; Burch, Neil; Lisý, Viliam; Morrill, Dustin; Bard, Nolan; Davis, Trevor; Waugh, Kevin; Johanson, Michael; Bowling, Michael

    2017-05-05

    Artificial intelligence has seen several breakthroughs in recent years, with games often serving as milestones. A common feature of these games is that players have perfect information. Poker, the quintessential game of imperfect information, is a long-standing challenge problem in artificial intelligence. We introduce DeepStack, an algorithm for imperfect-information settings. It combines recursive reasoning to handle information asymmetry, decomposition to focus computation on the relevant decision, and a form of intuition that is automatically learned from self-play using deep learning. In a study involving 44,000 hands of poker, DeepStack defeated, with statistical significance, professional poker players in heads-up no-limit Texas hold'em. The approach is theoretically sound and is shown to produce strategies that are more difficult to exploit than prior approaches. Copyright © 2017, American Association for the Advancement of Science.

  16. Diagnosing postural tachycardia syndrome: comparison of tilt testing compared with standing haemodynamics.

    Science.gov (United States)

    Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R

    2013-01-01

    POTS (postural tachycardia syndrome) is characterized by an increased heart rate (ΔHR) of ≥30 bpm (beats/min) with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of tilt and stand testing. ΔHR values were analysed at 5 min intervals. ROC (receiver operating characteristic) analysis was performed to determine optimal cut point values of ΔHR for both tilt and stand. Tilt produced larger ΔHR than stand for all 5 min intervals from 5 min (38±3 bpm compared with 33±3 bpm; P=0.03) to 30 min (51±3 bpm compared with 38±3 bpm; Pbpm criterion was similar for all tests (TILT10=93%, STAND10=87%, TILT30=100%, and STAND30=93%). Sp (specificity) of the 30 bpm criterion was less at both 10 and 30 min for tilt (TILT10=40%, TILT30=20%) than stand (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for tilt (with lower Sp for POTS diagnosis) than stand at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min tilt. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used.

  17. Optical interactions of aircraft windscreens and HUDs (Head-Up Displays) producing diplopia

    Science.gov (United States)

    Genco, L. V.

    1983-12-01

    The Air Force is in the process of evaluating new, wide field of view heads-up displays (WFOV HUDs) capable of presenting an enhanced array of visual imagery to pilots of modern aircraft. The main findings of this study are: (1) observers are relatively intolerant of negative disparity, (2) longer viewing is more likely to lead to a diplopia effect than very short glances, (3) resistance to disparity appears to be an individual trait, and (4) a large proportion of responses involve suppression of the view from one eye. The overall median negative disparity threshold was 1.2 mrad and the overall positive threshold was 2.6 mrad. These values are recommended as the maximum disparities acceptable for wide-field-of-view Canopy-HUD optical systems. Since the values are so small, we further recommend that the canopy and HUD be treated as a system, with technical interaction between the vendors, and between the vendors and the USAF. The disparity values indicate the net difference between both system components, so optimization may be possible by appropriately matching the optics.

  18. Novel microscope-integrated stereoscopic heads-up display for intrasurgical optical coherence tomography.

    Science.gov (United States)

    Shen, Liangbo; Carrasco-Zevallos, Oscar; Keller, Brenton; Viehland, Christian; Waterman, Gar; Hahn, Paul S; Kuo, Anthony N; Toth, Cynthia A; Izatt, Joseph A

    2016-05-01

    Intra-operative optical coherence tomography (OCT) requires a display technology which allows surgeons to visualize OCT data without disrupting surgery. Previous research and commercial intrasurgical OCT systems have integrated heads-up display (HUD) systems into surgical microscopes to provide monoscopic viewing of OCT data through one microscope ocular. To take full advantage of our previously reported real-time volumetric microscope-integrated OCT (4D MIOCT) system, we describe a stereoscopic HUD which projects a stereo pair of OCT volume renderings into both oculars simultaneously. The stereoscopic HUD uses a novel optical design employing spatial multiplexing to project dual OCT volume renderings utilizing a single micro-display. The optical performance of the surgical microscope with the HUD was quantitatively characterized and the addition of the HUD was found not to substantially effect the resolution, field of view, or pincushion distortion of the operating microscope. In a pilot depth perception subject study, five ophthalmic surgeons completed a pre-set dexterity task with 50.0% (SD = 37.3%) higher success rate and in 35.0% (SD = 24.8%) less time on average with stereoscopic OCT vision compared to monoscopic OCT vision. Preliminary experience using the HUD in 40 vitreo-retinal human surgeries by five ophthalmic surgeons is reported, in which all surgeons reported that the HUD did not alter their normal view of surgery and that live surgical maneuvers were readily visible in displayed stereoscopic OCT volumes.

  19. Through the Google Glass: The impact of heads-up displays on visual attention.

    Science.gov (United States)

    Lewis, Joanna E; Neider, Mark B

    2016-01-01

    In five experiments, we evaluated how secondary information presented on a heads-up display (HUD) impacts performance of a concurrent visual attention task. To do so, we had participants complete a primary visual search task under a variety of secondary load conditions (a single word presented on Google Glass during each search trial). Processing of secondary information was measured through a recognition memory task. Other manipulations included relevance (Experiments 1-4) and temporal onset of secondary information relative to the primary task (Experiment 3). Secondary information was always disruptive to the visual search, regardless of temporal onset and even when participants were instructed to ignore it. These patterns were evident in search tasks reflective of both selective (Experiments 1-3) and preattentive (Experiment 4) attentional mechanisms, and were not a result of onset-offset attentional capture (Experiment 5). Recognition memory for secondary information was always above chance. Our findings suggest that HUD-based visual information is profoundly disruptive to attentional processes and largely immune to user-centric prioritization.

  20. Toward Head-Up and Head-Worn Displays for Equivalent Visual Operations

    Science.gov (United States)

    Prinzel, Lawrence J., III; Arthur, Jarvis J.; Bailey, Randall E.; Shelton, Kevin J.; Kramer, Lynda J.; Jones, Denise R.; Williams, Steven P.; Harrison, Stephanie J.; Ellis, Kyle K.

    2015-01-01

    A key capability envisioned for the future air transportation system is the concept of equivalent visual operations (EVO). EVO is the capability to achieve the safety of current-day Visual Flight Rules (VFR) operations and maintain the operational tempos of VFR irrespective of the weather and visibility conditions. Enhanced Flight Vision Systems (EFVS) offer a path to achieve EVO. NASA has successfully tested EFVS for commercial flight operations that has helped establish the technical merits of EFVS, without reliance on natural vision, to runways without category II/III ground-based navigation and lighting requirements. The research has tested EFVS for operations with both Head-Up Displays (HUDs) and "HUD equivalent" Head-Worn Displays (HWDs). The paper describes the EVO concept and representative NASA EFVS research that demonstrate the potential of these technologies to safely conduct operations in visibilities as low as 1000 feet Runway Visual Range (RVR). Future directions are described including efforts to enable low-visibility approach, landing, and roll-outs using EFVS under conditions as low as 300 feet RVR.

  1. Low cost heads-up virtual reality (HUVR) with optical tracking and haptic feedback

    Science.gov (United States)

    Margolis, Todd; DeFanti, Thomas A.; Dawe, Greg; Prudhomme, Andrew; Schulze, Jurgen P.; Cutchin, Steve

    2011-03-01

    Researchers at the University of California, San Diego, have created a new, relatively low-cost augmented reality system that enables users to touch the virtual environment they are immersed in. The Heads-Up Virtual Reality device (HUVR) couples a consumer 3D HD flat screen TV with a half-silvered mirror to project any graphic image onto the user's hands and into the space surrounding them. With his or her head position optically tracked to generate the correct perspective view, the user maneuvers a force-feedback (haptic) device to interact with the 3D image, literally 'touching' the object's angles and contours as if it was a tangible physical object. HUVR can be used for training and education in structural and mechanical engineering, archaeology and medicine as well as other tasks that require hand-eye coordination. One of the most unique characteristics of HUVR is that a user can place their hands inside of the virtual environment without occluding the 3D image. Built using open-source software and consumer level hardware, HUVR offers users a tactile experience in an immersive environment that is functional, affordable and scalable.

  2. Low cost heads-up virtual reality (HUVR) with optical tracking and haptic feedback

    KAUST Repository

    Margolis, Todd

    2011-01-23

    Researchers at the University of California, San Diego, have created a new, relatively low-cost augmented reality system that enables users to touch the virtual environment they are immersed in. The Heads-Up Virtual Reality device (HUVR) couples a consumer 3D HD flat screen TV with a half-silvered mirror to project any graphic image onto the user\\'s hands and into the space surrounding them. With his or her head position optically tracked to generate the correct perspective view, the user maneuvers a force-feedback (haptic) device to interact with the 3D image, literally \\'touching\\' the object\\'s angles and contours as if it was a tangible physical object. HUVR can be used for training and education in structural and mechanical engineering, archaeology and medicine as well as other tasks that require hand-eye coordination. One of the most unique characteristics of HUVR is that a user can place their hands inside of the virtual environment without occluding the 3D image. Built using open-source software and consumer level hardware, HUVR offers users a tactile experience in an immersive environment that is functional, affordable and scalable.

  3. "Head up and eyes out" advances in head mounted displays capabilities

    Science.gov (United States)

    Cameron, Alex

    2013-06-01

    There are a host of helmet and head mounted displays, flooding the market place with displays which provide what is essentially a mobile computer display. What sets aviators HMDs apart is that they provide the user with accurate conformal information embedded in the pilots real world view (see through display) where the information presented is intuitive and easy to use because it overlays the real world (mix of sensor imagery, symbolic information and synthetic imagery) and enables them to stay head up, eyes out, - improving their effectiveness, reducing workload and improving safety. Such systems are an enabling technology in the provision of enhanced Situation Awareness (SA) and reducing user workload in high intensity situations. Safety Is Key; so the addition of these HMD functions cannot detract from the aircrew protection functions of conventional aircrew helmets which also include life support and audio communications. These capabilities are finding much wider application in new types of compact man mounted audio/visual products enabled by the emergence of new families of micro displays, novel optical concepts and ultra-compact low power processing solutions. This papers attempts to capture the key drivers and needs for future head mounted systems for aviation applications.

  4. High color fidelity thin film multilayer systems for head-up display use

    Science.gov (United States)

    Tsou, Yi-Jen D.; Ho, Fang C.

    1996-09-01

    Head-up display is gaining increasing access in automotive vehicles for indication and position/navigation purposes. An optical combiner, which allows the driver to receive image information from outside and inside of the automobile, is the essential part of this display device. Two multilayer thin film combiner coating systems with distinctive polarization selectivity and broad band spectral neutrality are discussed. One of the coating systems was designed to be located at the lower portion of the windshield. The coating reduced the exterior glare by approximately 45% and provided about 70% average see-through transmittance in addition to the interior information display. The other coating system was designed to be integrated with the sunshield located at the upper portion of the windshield. The coating reflected the interior information display while reducing direct sunlight penetration to 25%. Color fidelity for both interior and exterior images were maintained in both systems. This facilitated the display of full-color maps. Both coating systems were absorptionless and environmentally durable. Designs, fabrication, and performance of these coating systems are addressed.

  5. 78 FR 32253 - Announcement of Requirements and Registration for “Be Heads Up About Concussion Safety” Poster...

    Science.gov (United States)

    2013-05-29

    ... returned to contestants. You can use graphic design and other creative methods (including, but not limited... professional attacks. (4) We will only accept original graphic design and other creative methods (including... Registration for ``Be Heads Up About Concussion Safety'' Poster Design Contest Authority: 15 U.S.C. 3719...

  6. Backup Alignment Devices on Shuttle: Heads-Up Display or Crew Optical Alignment Sight

    Science.gov (United States)

    Chavez, Melissa A.

    2011-01-01

    NASA s Space Shuttle was built to withstand multiple failures while still keeping the crew and vehicle safe. Although the design of the Space Shuttle had a great deal of redundancy built into each system, there were often additional ways to keep systems in the best configuration if a failure were to occur. One such method was to use select pieces of hardware in a way for which they were not primarily intended. The primary function of the Heads-Up Display (HUD) was to provide the crew with a display of flight critical information during the entry phase. The primary function of the Crew Optical Alignment Sight (COAS) was to provide the crew an optical alignment capability for rendezvous and docking phases. An alignment device was required to keep the Inertial Measurement Units (IMUs) well aligned for a safe Entry; nominally this alignment device would be the two on-board Star Trackers. However, in the event of a Star Tracker failure, the HUD or COAS could also be used as a backup alignment device, but only if the device had been calibrated beforehand. Once the HUD or COAS was calibrated and verified then it was considered an adequate backup to the Star Trackers for entry IMU alignment. There were procedures in place and the astronauts were trained on how to accurately calibrate the HUD or COAS and how to use them as an alignment device. The calibration procedure for the HUD and COAS had been performed on many Shuttle missions. Many of the first calibrations performed were for data gathering purposes to determine which device was more accurate as a backup alignment device, HUD or COAS. Once this was determined, the following missions would frequently calibrate the HUD in order to be one step closer to having the device ready in case it was needed as a backup alignment device.

  7. Prueba de inclinación (“Head-up Tilt Test”, lecciones aprendidas en 564 casos consecutivos: Lessons Learned from 564 Consecutive Cases

    Directory of Open Access Journals (Sweden)

    Oswaldo Gutiérrez-Sotelo

    2012-03-01

    Full Text Available Introducción. El síncope es un motivo frecuente de consulta; el mecanismo causal más común es el reflejo, que incluye el síncope neurocardiogénico (SN, la hipotensión ortostática, la hipersensibilidad del seno carotídeo, entre otros. Estas variantes se valoran mediante la prueba de inclinación, con o sin estímulo farmacológico con nitroglicerina. El presente estudio recoge la experiencia con este examen auxiliar realizado en nuestro centro en los últimos 8 años. Material y métodos. Es un estudio retrospectivo, en el que se analizaron los resultados de las pruebas de inclinación realizadas a los pacientes que fueron referidos consecutivamente a nuestro centro en el período julio 2003 - agosto 2010. La información se obtuvo de la base de datos electrónica, así como del interrogatorio de los síntomas que motivaron la solicitud de la prueba. Resultados. Se incluyeron los datos de 564 pruebas de inclinación; la edad promedio fue 36,33±18,4 años (6-89, a predominio el sexo femenino (373, hombres 191. El motivo de realización de la prueba fue: historia de síncope (67%, lipotimia (26% y otros. El examen fue anormal en 470 pacientes (92 negativos, sensibilidad global 83,6 y los diagnósticos fueron: 118 SN tipo vasodilatador (25%, 112 SN tipo cardioinhibitorio (24% y 157 SN de tipo mixto (33%; 60 pacientes presentaron taquicardia postural ortostática (12% y 24 hipotensión ortostática (5%, 9 de los cuales tenía tratamiento farmacológico antihipertensivo; edad promedio 64 años. En 11 pacientes (2,3% se documentó hipersensibilidad del seno carotídeo, 9 de los cuales presentó también alguna forma de SN (edad promedio 60,63 años. Conclusión. La prueba de inclinación es adecuadamente sensible para la valoración del paciente que se presenta con síncope, en especial, en pacientes jóvenes sin evidencia de cardiopatía estructural. El SN es la disautonomía más frecuente y es más prevalente en mujeres pero más pronunciado en hombres, mientras que la hipotensión ortostática y la hipersensibilidad del seno carotídeo predomina en personas mayores.

  8. Prueba de inclinación (“Head-up Tilt Test”), lecciones aprendidas en 564 casos consecutivos: Lessons Learned from 564 Consecutive Cases

    OpenAIRE

    Oswaldo Gutiérrez-Sotelo; Yorleny Alfaro-Badilla

    2012-01-01

    Introducción. El síncope es un motivo frecuente de consulta; el mecanismo causal más común es el reflejo, que incluye el síncope neurocardiogénico (SN), la hipotensión ortostática, la hipersensibilidad del seno carotídeo, entre otros. Estas variantes se valoran mediante la prueba de inclinación, con o sin estímulo farmacológico con nitroglicerina. El presente estudio recoge la experiencia con este examen auxiliar realizado en nuestro centro en los últimos 8 años. Material y métodos. Es un est...

  9. Reduced systemic vascular resistance is the underlying hemodynamic mechanism in nitrate-stimulated vasovagal syncope during head-up tilt-table test

    Directory of Open Access Journals (Sweden)

    Byung Gyu Kim, MD

    2015-08-01

    Conclusions: Presyncopal symptoms during NTG-stimulated HUTT are SVR mediated, not cardiac output mediated. This study challenges the conventional idea of a decrease in cardiac output mediated by NTG as the overriding cause of presyncopal symptoms during HUTT.

  10. Pulsed Wave Doppler Ultrasound Is Useful to Assess Vasomotor Response in Patients with Multiple System Atrophy and Well Correlated with Tilt Table Study

    Directory of Open Access Journals (Sweden)

    Ke-Vin Chang

    2012-01-01

    Full Text Available The study aim was to assess sympathetic vasomotor response (SVR by using pulsed wave Doppler (PWD ultrasound in patients with multiple system atrophy (MSA and correlate with the tilt table study. We recruited 18 male patients and 10 healthy men as controls. The SVR of the radial artery was evaluated by PWD, using inspiratory cough as a provocative maneuver. The response to head-up tilt was studied by a tilt table with simultaneous heart rate and blood pressure recording. The hemodynamic variables were compared between groups, and were examined by correlation analysis. Regarding SVR, MSA patients exhibited a prolonged latency and less heart rate acceleration following inspiratory cough. Compared with the tilt table test, the elevation of heart rate upon SVR was positively correlated to the increase of heart rate after head-up tilt. The correlation analysis indicated that the magnitude of blood pressure drop from supine to upright was positively associated with the SVR latency but negatively correlated with the heart rate changes upon SVR. The present study demonstrated that blunted heart rate response might explain MSA's vulnerability to postural challenge. PWD may be used to predict cardiovascular response to orthostatic stress upon head-up tilt in MSA patients.

  11. Real-time Video-Streaming to Surgical Loupe Mounted Head-Up Display for Navigated Meningioma Resection.

    Science.gov (United States)

    Diaz, Roberto; Yoon, Jang; Chen, Robert; Quinones-Hinojosa, Alfredo; Wharen, Robert; Komotar, Ricardo

    2017-04-30

    Wearable technology interfaces with normal human movement and function, thereby enabling more efficient and adaptable use.We developed a wearable display system for use with intra-operative neuronavigation for brain tumor surgery. The Google glass head-up display system was adapted to surgical loupes with a video-streaming integrated hardware and software device for display of the Stealth S7 navigation screen. Phantom trials of surface ventriculostomy were performed. The device was utilized as an alternative display screen during cranial surgery. Image-guided brain tumor resection was accomplished using Google Glass head-up display of Stealth S7 navigation images. Visual display consists of navigation video-streaming over a wireless network. The integrated system developed for video-streaming permits video data display to the operating surgeon without requiring movement of the head away from the operative field. Google Glass head-up display can be used for intra-operative neuronavigation in the setting of intracranial tumor resection.

  12. Evaluation of models to predict insolation on tilted surfaces

    Science.gov (United States)

    Klucher, T. M.

    1979-01-01

    An empirical study was performed to evaluate the validity of various insolation models which employ either an isotropic or an anisotropic distribution approximation for sky light when predicting insolation on tilted surfaces. Data sets of measured hourly insolation values were obtained over a 6-month period using pyranometers which received diffuse and total solar radiation on a horizontal plane and total radiation on surfaces tilted toward the equator at 37 degrees and 60 degrees angles above the horizon. Data on the horizontal surfaces were used in the insolation models to predict insolation on the tilted surface; comparisons of measured vs calculated insolation on the tilted surface were examined to test the validity of the sky light approximations. It was found that the Liu-Jordan isotropic distribution model provides a good fit to empirical data under overcast skies but underestimates the amount of solar radiation incident on tilted surfaces under clear and partly cloudy conditions.

  13. Vehicle with tilting suspension system

    OpenAIRE

    Festini, Andrea; Tonoli, Andrea; Cavalli, Fabio; Carabelli, Stefano

    2006-01-01

    The patent is relative to the application of a tilting suspension on a snowmobile to improve its drive feeling and safety. At high speed the introduction of the tilting suspension reduce the rollover risk during cornering. The vehicle can tilt as a motorcycle and its lateral dimensions can be reduced not compromising the vehicle stability

  14. Tilt-table testing as a predictor of + GZ tolerance

    Directory of Open Access Journals (Sweden)

    Zawadzka-Bartczak E

    2005-11-01

    Full Text Available BACKGROUND: G-tolerance assessment is an essential element of both military pilot and pilot candidate evaluation. AIMS: Attempt at prediction of individual relaxed + Gz tolerance on the basis of head-up tilt (HUT testing. SETTINGS AND DESIGN: In two stages, 20 healthy men at the mean age 21.5 years took part in this study. The first stage, a 45 min, HUT test was performed using the Westminster protocol. During the second stage each underwent a centrifuge evaluation in response to gradual onset rate profiles. METHODS AND MATERIAL: In each subject, heart rate (HR and blood pressure (BP before and at 2, 15 and 45 min of the tilt-test were recorded. The gravity-load centrifuge (GOR studies were carried out [following the standard GOR programme, at 0.1 G/s rate of gravity load increase until the gravity load tolerance limit (loss of peripheral vision was reached]. STATISTICAL ANALYSIS USED: Relationships between variables were explored using Kendall′s tau-B correlation coefficient. The critical P-level was one-tailed 0.05. RESULTS: In four of 20 subjects (20%, vasovagal syncope occurred during the tilt test. G-level tolerance of this group (of +Gz accelerations lay in the range from +4 to +8.1 Gz, (+5.72 ? 0.86 Gz average and was comparable to the group without syncope. Loss of consciousness did not occur in any subjects during the centrifuge test. No statistically significant correlation was observed between HR and BP during tilt test and tolerance to +Gz accelerations. CONCLUSIONS: The result of tilt testing, carried out according to the Westminster protocol, was not useful in predicting individual tolerance to +Gz gravity loads.

  15. A single-tilt TEM stereomicroscopy technique for crystalline materials.

    Science.gov (United States)

    McCabe, Rodney J; Misra, Amit; Mitchell, Terence E; Alexander, Kathleen B

    2003-02-01

    A new single-tilt technique for performing TEM stereomicroscopy of strain fields in crystalline materials has been developed. The technique is a weak beam technique that involves changing the value of g and/or s g while tilting across a set of Kikuchi bands. The primary benefit of the technique is it can be used with single-tilt TEM specimen holders including many specialty holders such as in situ straining, heating, and cooling holders. Standard stereo-TEM techniques are almost always limited to holders allowing two degrees of rotational freedom (i.e., double-tilt or tilt/rotation holders). An additional benefit of the new technique is that it eliminates the need to focus with the specimen height control. These advantages make it useful for stereo viewing or for quantitative stereomicroscopy provided necessary consideration is given to errors that may result from the technique.

  16. Upright perception and ocular torsion change independently during head tilt

    Directory of Open Access Journals (Sweden)

    Amir Kheradmand

    2016-11-01

    Full Text Available We maintain a stable perception of the visual world despite continuous movements of our eyes, head and body. Perception of upright is a key aspect of such orientation constancy. Here we investigated whether changes in upright perception during sustained head tilt were related to simultaneous changes in torsional position of the eyes. We used a subjective visual vertical (SVV task, modified to track changes in upright perception over time, and a custom video method to measure ocular torsion simultaneously. We tested twelve subjects in upright position, during prolonged (~15min lateral head tilts of 20 degrees, and also after the head returned to upright position. While the head was tilted, SVV drifted in the same direction as the head tilt (left tilt: -5.4±1.4 o and right tilt: +2.2±2.1 o. After the head returned to upright position, there was an SVV aftereffect with respect to the pre-tilt baseline, which was also in the same direction as the head tilt (left tilt: -3.9±0.6 o and right tilt: +2.55±1.0 o. Neither the SVV drift nor the SVV aftereffect were correlated with the changes in ocular torsion. Using the Bayesian spatial-perception model we show that the pattern of SVV drift and aftereffect in our results could be explained by a drift and an adaptation in sensory inputs that encode head orientation. The fact that ocular torsion (mainly driven by the otoliths could not account for the perceptual changes suggests that neck proprioception could be the primary source of drift in upright perception during head tilt, and subsequently the aftereffect in upright position.

  17. Tilted string cosmologies

    Science.gov (United States)

    Clancy, Dominic; Feinstein, Alexander; Lidsey, James E.; Tavakol, Reza

    1999-04-01

    Global symmetries of the string effective action are employed to generate tilted, homogeneous Bianchi type VIh string cosmologies from a previously known stiff perfect fluid solution to Einstein gravity. The dilaton field is not constant on the surfaces of homogeneity. The future asymptotic state of the models is interpreted as a plane wave and is itself an exact solution to the string equations of motion to all orders in the inverse string tension. An inhomogeneous generalization of the Bianchi type III model is also found.

  18. Rigidity of tilting modules

    DEFF Research Database (Denmark)

    Let $U_q$ denote the quantum group associated with a finite dimensional semisimple Lie algebra. Assume that $q$ is a complex root of unity of odd order and that $U_q$ is %the quantum group version obtained via Lusztig's $q$-divided powers construction. We prove that all regular projective (tilting......$ and in this case as well as for type $A_2$ we calculate explicitly the Loewy structure for all regular Weyl modules. We also demonstrate that these results carry over to the modular case when the highest weights in question are in the so-called Jantzen region. At the same time we show by examples that as soon...

  19. 76 FR 17582 - Special Conditions: Bombardier Model BD-700-1A10 and BD-700-1A11 Airplanes, Head-Up Display (HUD...

    Science.gov (United States)

    2011-03-30

    ...-1A11 Airplanes, Head-Up Display (HUD) With Video Synthetic Vision System (SVS) AGENCY: Federal Aviation... Certificate Data Sheet (TCDS) T00003NY, those aircraft models are known under the marketing designation of...

  20. 76 FR 17062 - Special Conditions: Bombardier Model BD-700-1A10 and BD-700-1A11 Airplanes, Head-Up Display (HUD...

    Science.gov (United States)

    2011-03-28

    ...-1A11 Airplanes, Head-Up Display (HUD) With Video Synthetic Vision System (SVS) AGENCY: Federal Aviation... Certificate Data Sheet (TCDS) T00003NY, those aircraft models are known under the marketing designation of...

  1. 76 FR 31223 - Special Conditions: Bombardier Model BD-700-1A10 and BD-700-1A11 Airplanes, Head-up Display (HUD...

    Science.gov (United States)

    2011-05-31

    ...-1A11 Airplanes, Head-up Display (HUD) With Video Synthetic Vision System (SVS) AGENCY: Federal Aviation.... Per Type Certificate Data Sheet (TCDS) T00003NY, those aircraft models are known under the marketing...

  2. Effects of Vestibular Loss on Orthostatic Responses to Tilts in the Pitch Plane

    Science.gov (United States)

    Wood, Scott J.; Serrador, Jorge M.; Black, F. Owen; Rupert,Angus H.; Schlegel, Todd T.

    2004-01-01

    The purpose of this study was to determine the extent to which vestibular loss might impair orthostatic responses to passive tilts in the pitch plane in human subjects. Data were obtained from six subjects having chronic bilateral vestibular loss and six healthy individuals matched for age, gender, and body mass index. Vestibular loss was assessed with a comprehensive battery including dynamic posturography, vestibulo-ocular and optokinetic reflexes, vestibular evoked myogenic potentials, and ocular counterrolling. Head up tilt tests were conducted using a motorized two-axis table that allowed subjects to be tilted in the pitch plane from either a supine or prone body orientation at a slow rate (8 deg/s). The sessions consisted of three tilts, each consisting of20 min rest in a horizontal position, tilt to 80 deg upright for 10 min, and then return to the horizontal position for 5 min. The tilts were performed in darkness (supine and prone) or in light (supine only). Background music was used to mask auditory orientation cues. Autonomic measurements included beat-to-beat recordings of blood pressure (Finapres), heart rate (ECG), cerebral blood flow velocity in the middle cerebral artery (transcranial Doppler), end tidal CO2, respiratory rate and volume (Respritrace), and stroke volume (impedance cardiography). For both patients and control subjects, cerebral blood flow appeared to exhibit the most rapid adjustment following transient changes in posture. Outside of a greater cerebral hypoperfusion in patients during the later stages of tilt, responses did not differ dramatically between the vestibular loss and control subjects, or between tilts performed in light and dark room conditions. Thus, with the 'exception of cerebrovascular regulation, we conclude that orthostatic responses during slow postural tilts are not substantially impaired in humans following chronic loss of vestibular function, a result that might reflect compensation by nonvisual graviceptor

  3. Solar Tilt Measurement of Array for Building Application and Error Analysis

    OpenAIRE

    Agarwal, Abhishek; Vashishtha, Vineet Kumar; S N Mishra

    2016-01-01

    Abstract The optimum angle show some variations when compared with values reported in the literature. The amount of solar radiation incident on a tilted module surface is the component of the incident solar radiation which is perpendicular to the module surface. The array’s tilt is the angle in degrees from horizontal. A flat roof has 0 degree tilt and a vertical wall mount has a 90 degrees tilt angle. Whether you are installing solar panel on a flat roof or a pitched roof, the output of the ...

  4. Evaluation of Heart Rate Variation Analysis during Rest and Tilting in Patients with Temporal Lobe Epilepsy

    Directory of Open Access Journals (Sweden)

    Hanna Ansakorpi

    2011-01-01

    Full Text Available Objective. To evaluate spectral heart rate (HR variation using short-term ECG recordings at rest and during the tilt table test. Methods. The values of spectral components of total power (TP, high-frequency power (HF, low-frequency power (LF and LF: HF ratio were measured at rest and during the head-up tilt in patients with temporal lobe epilepsy (TLE and their control subjects. Results. Compared to the control subjects, patients with TLE had lower HF (<0.05 and LF : HF ratio (<0.05 at rest and lower TP (<0.001, HF (<0.05, and LF (<0.05 during the head-up tilt. Upon changing from supine to standing position TP (<0.05 and LF (<0.05 were attenuated in patients with TLE compared to the control subjects. Conclusion. These results suggest that spectral analysis of HR variation from ECG recordings of short duration may add value to assessment of autonomic nervous system function using autonomic cardiac tests in patients with TLE.

  5. Tilting Saturn without Tilting Jupiter or Ejecting an Ice Giant: Constraints on migration

    Science.gov (United States)

    McNeil, Douglas S.; Lee, M. H.

    2010-10-01

    The obliquities of the giant planets preserve information about their migration and encounter histories. Are the classic Nice models (Tsiganis et al. 2005) or the resonant Nice models (Morbidelli et al. 2007) compatible with Jupiter's 3 degree tilt and Saturn's 27? Here we consider the obliquity evolution of the giants during the planetesimal-driven migration phase using two methods: (1) a purely secular integration of the Laplace-Lagrange equations with spin, and (2) a hybrid N-body scheme with full interactions between the Sun and the giants but imposed prescriptions for migration and eccentricity and inclination damping. We find that it is difficult to reproduce today's obliquity values as migration timescales sufficient to tilt Saturn via the Hamilton & Ward (2004) secular spin-orbit resonance mechanism generally suffice to tilt Jupiter more than is observed. Moreover, long migration timescales which make tilting Saturn easier simultaneously reduce the survival fraction (to below 20% for timescales longer than 20 Myr.) We discuss the constraints these observations provide on the dynamical history of the giant planets, and the remaining possibility of tilting Saturn during a late very slow migration of Neptune to its present location after the main phase of migration is complete. [This work was supported by Hong Kong RGC grant HKU 7024/08P.

  6. Classical and quantum mechanics of diatomic molecules in tilted fields.

    Science.gov (United States)

    Arango, Carlos A; Kennerly, William W; Ezra, Gregory S

    2005-05-08

    We investigate the classical and quantum mechanics of diatomic molecules in noncollinear (tilted) static electric and nonresonant linearly polarized laser fields. The classical diatomic in tilted fields is a nonintegrable system, and we study the phase space structure for physically relevant parameter regimes for the molecule KCl. While exhibiting low-energy (pendular) and high-energy (free-rotor) integrable limits, the rotor in tilted fields shows chaotic dynamics at intermediate energies, and the degree of classical chaos can be tuned by changing the tilt angle. We examine the quantum mechanics of rotors in tilted fields. Energy-level correlation diagrams are computed, and the presence of avoided crossings quantified by the study of nearest-neighbor spacing distributions as a function of energy and tilting angle. Finally, we examine the influence of classical periodic orbits on rotor wave functions. Many wave functions in the tilted field case are found to be highly nonseparable in spherical polar coordinates. Localization of wave functions in the vicinity of classical periodic orbits, both stable and unstable, is observed for many states.

  7. A new tilt on pelvic radiographs: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Richards, P.J. [North Staffordshire Royal Infirmary, Department of Radiology, Stoke-on-Trent, Staffordshire (United Kingdom); Pattison, J.M. [University Hospital of North Staffordshire, Department of Radiology, Stoke on Trent (United Kingdom); Belcher, J. [Keele University, Department of Mathematics, Keele, Staffordshire (United Kingdom); DeCann, R.W. [IMECS, Department of Radiology, Market Drayton, Shropshire (United Kingdom); Anderson, Suzanne [University of Melbourne, Department of Radiology, Melbourne (Australia); Wynn-Jones, C. [University Hospital of North Staffordshire, Department of Orthopaedic Surgery, Stoke on Trent (United Kingdom)

    2009-02-15

    The aim of this study was to evaluate pelvic tilt on commonly performed measurements on radiography in primary protrusio acetabuli and developmental dysplasia of the hip. A dry assembled pelvis and spine skeleton was positioned in an isocentric skull unit and films exposed with increasing degrees of angulation of pelvic tilt. The films were then read by two independent readers for seven different measurements used to evaluate the hips and acetabular: acetabular line to ilioischial line, teardrop appearance, intercristal/intertuberous ratio, co-ordinates of femoral head, centre edge angle, acetabular depth/width ratio and acetabular angle. There was so much variation in the protrusio results that no formal recommendation of any standard radiographic test can be given. Only the inter tuberous distance is not effected by pelvic tilt. The acetabular angles for developmental dysplasia of the hip showed the most potential with pelvic tilt below 15 . As pelvic tilt increases, measurements used in protusio become unreliable, and computed tomography/magnetic resonance imaging are probably going to be more accurate as one can directly visualise pelvic intrusion. We recommend a lateral view to assess the degree of pelvic tilt in patients with protrusion to ensure these measurements are valid. (orig.)

  8. Observational Signatures of Tilted Black Hole Accretion Disks from Simulations

    CERN Document Server

    Dexter, Jason

    2011-01-01

    Geometrically thick accretion flows may be present in black hole X-ray binaries observed in the low/hard state and in low-luminosity active galactic nuclei. Unlike in geometrically thin disks, the angular momentum axis in these sources is not expected to align with the black hole spin axis. We compute images from three-dimensional general relativistic magnetohydrodynamic simulations of misaligned (tilted) accretion flows using relativistic radiative transfer, and compare the estimated locations of the radiation edge with expectations from their aligned (untilted) counterparts. The radiation edge in the tilted simulations is independent of black hole spin for a tilt of 15 degrees, in stark contrast to the results for untilted simulations, which agree with the monotonic dependence on spin expected from thin accretion disk theory. Synthetic emission line profiles from the tilted simulations depend strongly on the observer's azimuth, and exhibit unique features such as broad "blue wings." Coupled with precession,...

  9. Evaluating Tilt for Wind Plants

    Energy Technology Data Exchange (ETDEWEB)

    Annoni, Jennifer [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Scholbrock, Andrew K. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Churchfield, Matthew J. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Fleming, Paul A. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-07-03

    The objective of this work is to demonstrate the feasibility of tilt in a wind plant. Tilt control, much like other wind plant control strategies, has the potential to improve the performance of a wind plant. Tilt control uses the tilt angle of the turbine to direct the wake above or below the downstream turbines. This paper presents a study of tilt in two- and three-turbine arrays. Specifically, the authors show that the power production of a two-turbine array can be increased by tilting turbines in a specific orientation. When adding more turbines, as is shown with the three-turbine array, the overall percentage of power gain increases. This outcome deviates from some of the results seen in typical wind plant control strategies. Finally, we discuss the impact this type of control strategy has on the aerodynamics in a wind plant. This analysis demonstrates that a good understanding of wake characteristics is necessary to improve the plant's performance. A tilt strategy such as the one presented in this paper may have implications for future control/optimization studies including optimization of hub heights in a wind plant and analysis of deep array effects.

  10. REPETITIVE CLUSTER-TILTED ALGEBRAS

    Institute of Scientific and Technical Information of China (English)

    Zhang Shunhua; Zhang Yuehui

    2012-01-01

    Let H be a finite-dimensional hereditary algebra over an algebraically closed field k and CFm be the repetitive cluster category of H with m ≥ 1.We investigate the properties of cluster tilting objects in CFm and the structure of repetitive clustertilted algebras.Moreover,we generalize Theorem 4.2 in [12](Buan A,Marsh R,Reiten I.Cluster-tilted algebra,Trans.Amer.Math.Soc.,359(1)(2007),323-332.) to the situation of CFm,and prove that the tilting graph KCFm of CFm is connected.

  11. Use of Minute-by-Minute Cardiovascular Measurements During Tilt Tests to Strengthen Inference on the Effect of Long-Duration Space Flight on Orthostatic Hypotension

    Science.gov (United States)

    Feiveson, Alan H.; Lee, Stuart M. C.; Stenger, Michael B.; Stein, Sydney P.; Platts, Steven H.

    2011-01-01

    Typical methodology for evaluating the effects of spaceflight on orthostatic hypotension (OH) has been survival analysis of tolerance times from 80 head-up tilt tests. However when scheduled test durations are short, there may not be enough failures to allow survival analysis to adequately estimate and compare the effects of flight phase (e.g. pre-flight, number of days post-flight), flight duration, and their interaction, as well as interactions with effects of interventions or countermeasures. The problem is exacerbated in the presence of a repeated measures design, in which subjects participate in tilt tests during various flight phases. Here we show how it is possible to dramatically improve the efficiency of statistical inference in this setting by making use of the additional information contained in minute-by-minute observations of cardiovascular parameters thought to be reflective of progression towards presyncope during tilt testing. Methods: We retrospectively examined operational tilt test (OTT; 10 -min 80 head-up tilt) data from 20 International Space Station (ISS) and 66 Shuttle astronauts 10 d before launch (L-10), on landing day (R+0) and during recovery (R+1, R+3, R+6-10) depending on the level of participation. Data from 5 ISS astronauts tested on R+0 or R+1 who used non-standard countermeasures were excluded. In addition to OTT survival time, 8 cardiovascular parameters (CP: heart rate, systolic, diastolic, and mean arterial blood pressure, pulse pressure, stroke volume, cardiac output, and total peripheral resistance) that might be predictive of progression towards presyncope were measured every minute of each OTT. Statistical analysis was predicated on a two ]stage model of causation. In the first stage, flight duration and time from landing affect the astronauts' degree of OH, which is manifested in the time trends and variation of the above CPs during OTTs. In the second stage, the behavior of these parameters directly affects OTT survival

  12. Evaluation of a Head-Worn Display System as an Equivalent Head-Up Display for Low Visibility Commercial Operations

    Science.gov (United States)

    Arthur, Jarvis (Trey) J., III; Shelton, Kevin J.; Prinzel, Lawrence J.; Nicholas, Stephanie N.; Williams, Steven P.; Ellis, Kyle E.; Jones, Denise R.; Bailey, Randall E.; Harrison, Stephanie J.; Barnes, James R.

    2017-01-01

    Research, development, test, and evaluation of fight deck interface technologies is being conducted by the National Aeronautics and Space Administration (NASA) to proactively identify, develop, and mature tools, methods, and technologies for improving overall aircraft safety of new and legacy vehicles operating in the Next Generation Air Transportation System (NextGen). One specific area of research was the use of small Head-Worn Displays (HWDs) to serve as a possible equivalent to a Head-Up Display (HUD). A simulation experiment and a fight test were conducted to evaluate if the HWD can provide an equivalent level of performance to a HUD. For the simulation experiment, airline crews conducted simulated approach and landing, taxi, and departure operations during low visibility operations. In a follow-on fight test, highly experienced test pilots evaluated the same HWD during approach and surface operations. The results for both the simulation and fight tests showed that there were no statistical differences in the crews' performance in terms of approach, touchdown and takeoff; but, there are still technical hurdles to be overcome for complete display equivalence including, most notably, the end-to-end latency of the HWD system.

  13. A heads-up no-limit Texas Hold'em poker player: Discretized betting models and automatically generated equilibrium-finding programs

    DEFF Research Database (Denmark)

    Gilpin, Andrew G.; Sandholm, Tuomas; Sørensen, Troels Bjerre

    2008-01-01

    We present Tartanian, a game theory-based player for heads-up no-limit Texas Hold'em poker. Tartanian is built from three components. First, to deal with the virtually infinite strategy space of no-limit poker, we develop a discretized betting model designed to capture the most important strategic...

  14. An observational method to code concussions in the National Hockey League (NHL): the heads-up checklist.

    Science.gov (United States)

    Hutchison, Michael G; Comper, Paul; Meeuwisse, Willem H; Echemendia, Ruben J

    2014-01-01

    Development of effective strategies for preventing concussions is a priority in all sports, including ice hockey. Digital video records of sports events contain a rich source of valuable information, and are therefore a promising resource for analysing situational factors and injury mechanisms related to concussion. To determine whether independent raters reliably agreed on the antecedent events and mechanisms of injury when using a standardised observational tool known as the heads-up checklist (HUC) to code digital video records of concussions in the National Hockey League (NHL). The study occurred in two phases. In phase 1, four raters (2 naïve and 2 expert) independently viewed and completed HUCs for 25 video records of NHL concussions randomly chosen from the pool of concussion events from the 2006-2007 regular season. Following initial analysis, three additional factors were added to the HUC, resulting in a total of 17 factors of interest. Two expert raters then viewed the remaining concussion events from the 2006-2007 season, as well as all digital video records of concussion events up to 31 December 2009 (n=174). For phase 1, the majority of the factors had a κ value of 0.6 or higher (8 of 15 factors for naïve raters; 11 of 15 factors for expert raters). For phase 2, all the factors had a total percent agreement value greater than 0.8 and κ values of >0.65 for the expert raters. HUC is an objective, reliable tool for coding the antecedent events and mechanisms of concussions in the NHL.

  15. Fabrication and Characterization of Tilted Fiber Optic Bragg Grating Filters over Various Wavelengths

    Science.gov (United States)

    Grant, Joseph; Jackson, Kurt V.; Wang, Y.; Sharma, A.; Burdine, Robert V. (Technical Monitor)

    2002-01-01

    Fiber Optic Bragg Grating taps are fabricated and characterized at various wavelengths using a modified Talbot interferometric technique. Gratings are fabricated by tilting the photosensitive fiber to angles up to 45 degrees w.r.t. the writing angle. Diffraction characteristics of the tilted grating is monitored in first and second orders.

  16. Tibiotalar tilt - a new slant

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, H.; Wandtke, J.

    1981-05-01

    Classically tibiotalar tilt (TTT) is associated with four conditions: Fairbanks disease, hemophilia, sickle-cell anemia and juvenile rheumatoid arthritis. We have found it to be present in at least 20 other conditions including other dysplasias, developmental conditions such as fibrous dysplasia and a variety of other acquired disorders including various metabolic diseases and following previous trauma. The pathogenesis is controversial, but the most probable cause is related to stress and the blood supply of the distal tibial epiphysis. The differentiation of TTT from pseudotibiotalar tilt is also discussed.

  17. Height and Tilt Geometric Texture

    DEFF Research Database (Denmark)

    Andersen, Vedrana; Desbrun, Mathieu; Bærentzen, Jakob Andreas

    2009-01-01

    We propose a new intrinsic representation of geometric texture over triangle meshes. Our approach extends the conventional height field texture representation by incorporating displacements in the tangential plane in the form of a normal tilt. This texture representation offers a good practical...... compromise between functionality and simplicity: it can efficiently handle and process geometric texture too complex to be represented as a height field, without having recourse to full blown mesh editing algorithms. The height-and-tilt representation proposed here is fully intrinsic to the mesh, making...

  18. Magnetic nanocap arrays with tilted magnetization

    Science.gov (United States)

    Albrecht, Manfred

    2009-03-01

    In modern magnetic recording materials the ``superparamagnetic effect'' has become increasingly important as new magnetic hard disk drive products are designed for higher storage densities. In this regard, patterned media [1], where two-dimensional arrays of nanostructures are used, is one of the concepts that might provide the required areal density in future magnetic recording devices. However, also nanostructure arrays will ultimately need high anisotropy material such as L10-FePt to provid enough thermal stability and thus much higher writing fields than currently obtainable from perpendicular magnetic recording heads. One proposed solution to this problem is the use of tilted magnetic recording media [2]. The basic idea is to tilt the easy axis of the magnetic medium from the perpendicular direction to 45 degree. In this case, the switching field will be reduced by a foctor of two in the Stoner-Wohlfarth limit. Recently, this approach was realized by oblique film deposition onto arrays of self-assembled spherical particles [3-5]. In this presentation, recent results on different film systems including Co/Pt multilayers, FePt and CoPtCr-SiO2 alloys which have been deposited onto SiO2 particle monolayers will be presented. It turned out that by tuning the growth conditions single domain nanocaps with enhanced magnetic coercivity and tilted anisostropy axis can be achieved even for particle sizes below 50 nm. [4pt] [1] B. D. Terris and T. Thomson, J. Phys. D: Appl. Phys. 38 (2005) R199 [0pt] [2] J.-P. Wang, Nat. Mater. 4, 191 (2005). [0pt] [3] M. Albrecht et al., Nat. Mater. 4, 203 (2005). [0pt] [4] T. Ulbrich et al., Phys. Rev. Lett. 96 (2006) 077202. [0pt] [5] D. Makarov et al., Appl. Phys. Lett. 93, 153112 (2008).

  19. High tilt susceptibility of the Scintrex CG-5 relative gravimeters

    Science.gov (United States)

    Reudink, R.; Klees, R.; Francis, O.; Kusche, J.; Schlesinger, R.; Shabanloui, A.; Sneeuw, N.; Timmen, L.

    2014-06-01

    We report on the susceptibility of the Scintrex CG-5 relative gravimeters to tilting, that is the tendency of the instrument of providing incorrect readings after being tilted (even by small angles) for a moderate period of time. Tilting of the instrument can occur when in transit between sites usually on the backseat of a car even using the specially designed transport case. Based on a series of experiments with different instruments, we demonstrate that the readings may be offset by tens of Gal. In addition, it may take hours before the first reliable readings can be taken, with the actual time depending on how long the instrument had been tilted. This sensitivity to tilt in combination with the long time required for the instrument to provide reliable readings has not yet been reported in the literature and is not addressed adequately in the Scintrex CG-5 user manual. In particular, the inadequate instrument state cannot easily be detected by checking the readings during the observation or by reviewing the final data before leaving a site, precautions suggested by Scintrex Ltd. In regional surveys with car transportation over periods of tens of minutes to hours, the gravity measurements can be degraded by some 10 Gal. To obtain high-quality results in line with the CG-5 specifications, the gravimeters must remain in upright position to within a few degrees during transits. This requirement may often be unrealistic during field observations, particularly when observing in hilly terrain or when walking with the instrument in a backpack.

  20. Cerebral Blood Flow, Heart Rate, and Blood Pressure Patterns during the Tilt Test in Common Orthostatic Syndromes

    Directory of Open Access Journals (Sweden)

    Peter Novak

    2016-01-01

    Full Text Available Objective. The head-up tilt test is widely used for evaluation of orthostatic intolerance. Although orthostatic symptoms usually reflect cerebral hypoperfusion, the cerebral blood flow velocity (CBFv profile in orthostatic syndromes is not well described. This study evaluated CBFv and cardiovascular patterns associated with the tilt test in common orthostatic syndromes. Methods. This retrospective study analyzed the tilt test of patients with history of orthostatic intolerance. The following signals were recorded: ECG, blood pressure, CBFv using transcranial Doppler, respiratory signals, and end tidal CO2. Results. Data from 744 patients were analyzed. Characteristic pattern associated with a particular orthostatic syndrome can be grouped into abnormalities predominantly affecting blood pressure (orthostatic hypotension, orthostatic hypertension syndrome, vasomotor oscillations, and neurally mediated syncope—cardioinhibitory, vasodepressor, and mixed, cerebral blood flow (orthostatic hypoperfusion syndrome, primary cerebral autoregulatory failure, and heart rate (tachycardia syndromes: postural tachycardia syndrome, paroxysmal sinus tachycardia, and inappropriate sinus tachycardia. Psychogenic pseudosyncope is associated with stable CBFv. Conclusions. The tilt test is useful add-on in diagnosis of several orthostatic syndromes. However diagnostic criteria for several syndromes had to be modified to allow unambiguous pattern classification. CBFv monitoring in addition to blood pressure and heart rate may increase diagnostic yield of the tilt test.

  1. Cerebral Blood Flow, Heart Rate, and Blood Pressure Patterns during the Tilt Test in Common Orthostatic Syndromes

    Science.gov (United States)

    2016-01-01

    Objective. The head-up tilt test is widely used for evaluation of orthostatic intolerance. Although orthostatic symptoms usually reflect cerebral hypoperfusion, the cerebral blood flow velocity (CBFv) profile in orthostatic syndromes is not well described. This study evaluated CBFv and cardiovascular patterns associated with the tilt test in common orthostatic syndromes. Methods. This retrospective study analyzed the tilt test of patients with history of orthostatic intolerance. The following signals were recorded: ECG, blood pressure, CBFv using transcranial Doppler, respiratory signals, and end tidal CO2. Results. Data from 744 patients were analyzed. Characteristic pattern associated with a particular orthostatic syndrome can be grouped into abnormalities predominantly affecting blood pressure (orthostatic hypotension, orthostatic hypertension syndrome, vasomotor oscillations, and neurally mediated syncope—cardioinhibitory, vasodepressor, and mixed), cerebral blood flow (orthostatic hypoperfusion syndrome, primary cerebral autoregulatory failure), and heart rate (tachycardia syndromes: postural tachycardia syndrome, paroxysmal sinus tachycardia, and inappropriate sinus tachycardia). Psychogenic pseudosyncope is associated with stable CBFv. Conclusions. The tilt test is useful add-on in diagnosis of several orthostatic syndromes. However diagnostic criteria for several syndromes had to be modified to allow unambiguous pattern classification. CBFv monitoring in addition to blood pressure and heart rate may increase diagnostic yield of the tilt test. PMID:27525257

  2. Tilting Saturn without tilting Jupiter: Constraints on giant planet migration

    CERN Document Server

    Brasser, R

    2015-01-01

    The migration and encounter histories of the giant planets in our Solar System can be constrained by the obliquities of Jupiter and Saturn. We have performed secular simulations with imposed migration and N-body simulations with planetesimals to study the expected obliquity distribution of migrating planets with initial conditions resembling those of the smooth migration model, the resonant Nice model and two models with five giant planets initially in resonance (one compact and one loose configuration). For smooth migration, the secular spin-orbit resonance mechanism can tilt Saturn's spin axis to the current obliquity if the product of the migration time scale and the orbital inclinations is sufficiently large (exceeding 30 Myr deg). For the resonant Nice model with imposed migration, it is difficult to reproduce today's obliquity values, because the compactness of the initial system raises the frequency that tilts Saturn above the spin precession frequency of Jupiter, causing a Jupiter spin-orbit resonance...

  3. Resolution enhancement in tilted coordinates

    Science.gov (United States)

    Hariri Naghadeh, Diako; Keith Morley, Christopher

    2016-11-01

    Deconvolution is applied to remove source wavelet effects from seismograms. The results are resolution enhancement that enables detection of thin layers. Following enhancement of resolution, low frequency and high angle reflectors, particularly at great depth, appear as low amplitude and semi-invisible reflectors that are difficult to track and pick. A new approach to enhance resolution is introduced that estimates a derivative using continuous wavelet transform in tilted coordinates. The results are compared with sparse spike deconvolution, curvelet deconvolution and inverse quality filtering in wavelet domain. The positive consequence of the new method is to increase sampling of high dip features by changing the coordinate system from Cartesian to tilted. To compare those methods a complex data set was chosen that includes high angle faults and chaotic mass transport complex. Image enhancement using curvelet deconvolution shows a chaotic system as a non-chaotic one. The results show that sparse spike deconvolution and inverse quality filtering in wavelet domain are able to enhance resolution more than curvelet deconvolution especially at great depth but it is impossible to follow steep dip reflectors after resolution enhancement using these methods, especially when their apparent dips are more than 45°. By estimating derivatives in a continuous wavelet transform from tilted data sets similar resolution enhancement as the other deconvolution methods is achieved but additionally steep dipping reflectors are imaged much better than others. Subtracted results of the enhanced resolution data set using new method and the other introduced methods show that steeply dipping reflectors are highlighted as a particular ability of the new method. The results show that high frequency recovery in Cartesian co-ordinate is accompanied by inability to image steeply dipping reflectors especially at great depths. Conversely recovery of high frequency data and imaging of the data

  4. The Günther-Tulip retrievable filter: a method for assessing tilting of the filter.

    Science.gov (United States)

    Semiz-Oysu, Aslihan; Cho, Kyung J

    2010-04-01

    Tilting of the Günther-Tulip filter may be responsible for failure or difficulty to retrieve. Assessment of the filter tilt can be difficult when only AP imaging is available. This study is performed in vitro to develop a simple method to assess the Günther-Tulip filter for tilting. A model consisting of a plastic tube was used to simulate vena cava. A Günther-Tulip filter was placed centred or tilted within the tube at various positions and radiograms were taken in AP, lateral, and craniocaudally angled projections. The images were analysed to determine the actual degree of tilt, the distance between the limb hooks on AP radiograms and the craniocaudal angulation degree needed to align the limb hooks linearly. When the filter was centred or tilted laterally, all limb hooks of the filter were aligned linearly on AP radiograms. When the filter was tilted in AP or oblique direction, linear alignment of the limb hooks was lost and the ventral and dorsal limb hooks showed separation on AP projection. The amount of separation and the craniocaudal angles to align the filter hooks corresponded to actual tilt angles. Loss of linear alignment of limb hooks in AP radiograms may suggest the presence of tilt in the AP plane. Significant separation of limb hooks should be alarming for significant filter tilt, and further evaluation of the filter position by CT scan or lateral cavogram should be obtained prior to planning of the retrieval. Copyright 2009 Australasian Society of Cardiac and Thoracic Surgeons and the Cardiac Society of Australia and New Zealand. Published by Elsevier B.V. All rights reserved.

  5. A stepped wedge, cluster controlled trial of an intervention to improve safety and quality on medical wards: the HEADS-UP study protocol.

    Science.gov (United States)

    Pannick, Samuel; Beveridge, Iain; Ashrafian, Hutan; Long, Susannah J; Athanasiou, Thanos; Sevdalis, Nick

    2015-06-22

    The majority of preventable deaths in healthcare are due to errors on general wards. Staff perceptions of safety correlate with patient survival, but effectively translating ward teams' concerns into tangibly improved care remains problematic. The Hospital Event Analysis Describing Significant Unanticipated Problems (HEADS-UP) trial evaluates a structured, multidisciplinary team briefing, capturing safety threats and adverse events, with rapid feedback to clinicians and service managers. This is the first study to rigorously assess a simpler intervention for general medical units, alongside an implementation model applicable to routine clinical practice. 7 wards from 2 hospitals will progressively incorporate the intervention into daily practice over 14 months. Wards will adopt HEADS-UP in a pragmatic sequence, guided by local clinical enthusiasm. Initial implementation will be facilitated by a research lead, but rapidly delegated to clinical teams. The primary outcome is excess length of stay (a surplus stay of 24 h or more, compared to peer institutions' Healthcare Resource Groups-predicted length of stay). Secondary outcomes are 30-day readmission or excess length of stay; in-hospital death or death/readmission within 30 days; healthcare-acquired infections; processes of escalation of care; use of traditional incident-reporting systems; and patient safety and teamwork climates. HEADS-UP will be analysed as a stepped wedge cluster controlled trial. With 7840 patients, using best and worst case predictions, the study would achieve between 75% and 100% power to detect a 2-14% absolute risk reduction in excess length of stay (two-sided pmodels or generalised estimating equations, and a time-to-event regression model. A qualitative analysis will evaluate facilitators and barriers to HEADS-UP implementation and impact. Participating institutions' Research and Governance departments approved the study. Results will be published in peer-reviewed journals and at

  6. Intraoperative optical coherence tomography using an optimized reflective optical relay, real-time heads-up display, and semitransparent surgical instrumentation

    Science.gov (United States)

    Tao, Yuankai K.; El-Haddad, Mohamed T.; Srivastava, Sunil K.; Feiler, Daniel; Noonan, Amanda I.; Rollins, Andrew M.; Ehlers, Justis P.

    2015-03-01

    Ophthalmic surgical maneuvers are currently limited by the ability of surgeons to visualize and manipulate semitransparent tissue layers as thin as tens of microns. We describe several iterative advances in iOCT technology, including a novel iOCT system, real-time heads-up display (HUD) feedback, visualization of intraoperative maneuvers, and OCT-compatible surgical instrumentation. Simulated surgical maneuvers were performed on freshly enucleated porcine eyes. Subretinal space cannulation with injection was performed and imaged using spatial compounding. The optical properties of semitransparent materials were quantified to identify OCT-compatible substrates, and surgical instrument prototypes were machined, including corneal, surgical picks, and retinal forceps.

  7. Dark tip-tilt sensing

    CERN Document Server

    Arcidiacono, Carmelo; Viotto, Valentina; Bergomi, Maria; Farinato, Jacopo; Magrin, Demetrio; Dima, Marco; Gullieuszik, Marco; Marafatto, Luca

    2016-01-01

    Dark wavefront sensing in its simplest and more crude form is a quad-cell with a round spot of dark ink acting as occulting disk at the center. This sensor exhibits fainter limiting magnitude than a conventional quad-cell, providing that the size of the occulting disk is slightly smaller than the size of the spot and smaller than the residual jitter movement in closed loop. We present simulations focusing a generic Adaptive Optics system using Natural Guide Stars to provide the tip-tilt signal. We consider a jitter spectrum of the residual correction including amplitudes exceeding the dark disk size.

  8. Atlas of Tilted Accretion Disks & Source to Negative Superhumps

    CERN Document Server

    Montgomery, M M

    2009-01-01

    Using smoothed particle hydrodynamics, we numerically simulate steady state accretion discs for Cataclysmic Variable Dwarf Novae systems that have a secondary-to-primary mass ratio (0.35 \\le q \\le 0.55). After these accretion discs have come to quasi-equilibrium, we rotate each disc out of the orbital plane by (\\delta = (1, 2, 3, 4, 5,) or (20)^{o}) to induce negative superhumps. For accretion discs tilted $5^{o}$, we generate light curves and associated Fourier transforms for an atlas on negative superhumps and retrograde precession. Our simulation results suggest that accretion discs need to be tilted more than three degrees for negative superhumps to be statistically significant. We also show that if the disc is tilted enough such that the gas stream strikes a disc face, then a dense cooling ring is generated near the radius of impact. In addition to the atlas, we study these artificially tilted accretion discs to find the source to negative superhumps. Our results suggest that the source is additional lig...

  9. Estimation of beat-to-beat changes in stroke volume from arterial pressure: A comparison of two pressure wave analysis techniques during head- up tilt testing in young, healthy men

    NARCIS (Netherlands)

    Jellema, W.T.; Imholz, B.P.M.; Oosting, H.; Wesseling, K.H.; Lieshout, J.J. van

    1999-01-01

    Objective: The aim of this study was to compare beat-to-beat changes in stroke volume (SV) estimated by two different pressure wave analysis techniques during orthostatic stress testing: pulse contour analysis and Modelflow, ie, simulation of a three-element model of aortic input impedance. Methods:

  10. Molecular tilt on monolayer-protected nanoparticles

    KAUST Repository

    Giomi, L.

    2012-02-01

    The structure of the tilted phase of monolayer-protected nanoparticles is investigated by means of a simple Ginzburg-Landau model. The theory contains two dimensionless parameters representing the preferential tilt angle and the ratio ε between the energy cost due to spatial variations in the tilt of the coating molecules and that of the van der Waals interactions which favors the preferential tilt. We analyze the model for both spherical and octahedral particles. On spherical particles, we find a transition from a tilted phase, at small ε, to a phase where the molecules spontaneously align along the surface normal and tilt disappears. Octahedral particles have an additional phase at small ε characterized by the presence of six topological defects. These defective configurations provide preferred sites for the chemical functionalization of monolayer-protected nanoparticles via place-exchange reactions and their consequent linking to form molecules and bulk materials. Copyright © EPLA, 2012.

  11. Technical feasibility and safety of image-guided parieto-occipital ventricular catheter placement with the assistance of a wearable head-up display.

    Science.gov (United States)

    Yoon, Jang W; Chen, Robert E; ReFaey, Karim; Diaz, Roberto J; Reimer, Ronald; Komotar, Ricardo J; Quinones-Hinojosa, Alfredo; Brown, Benjamin L; Wharen, Robert E

    2017-05-19

    Wearable technology is growing in popularity as a result of its ability to interface with normal human movement and function. Using proprietary hardware and software, neuronavigation images were captured and transferred wirelessly via a password-encrypted network to the head-up display. The operating surgeon wore a loupe-mounted wearable head-up display during image-guided parieto-occipital ventriculoperitoneal shunt placement in two patients. The shunt placement was completed successfully without complications. The tip of the catheter ended well within the ventricles away from the ventricular wall. The wearable device allowed for continuous monitoring of neuronavigation images in the right upper corner of the surgeon's visual field without the need for the surgeon to turn his head to view the monitors. The adaptable nature of this proposed system permits the display of video data to the operating surgeon without diverting attention away from the operative task. This technology has the potential to enhance image-guided procedures. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Reverse breech extraction versus the standard approach of pushing the impacted fetal head up through the vagina in caesarean section for obstructed labour: A randomised controlled trial.

    Science.gov (United States)

    Nooh, Ahmed Mohamed; Abdeldayem, Hussein Mohammed; Ben-Affan, Othman

    2017-01-31

    The objective of this study was to assess effectiveness and safety of the reverse breech extraction approach in Caesarean section for obstructed labour, and compare it with the standard approach of pushing the fetal head up through the vagina. This randomised controlled trial included 192 women. In 96, the baby was delivered by the 'reverse breech extraction approach', and in the remaining 96, by the 'standard approach'. Extension of uterine incision occurred in 18 participants (18.8%) in the reverse breech extraction approach group, and 46 (47.9%) in the standard approach group (p = .0003). Two women (2.1%) in the reverse breech extraction approach group needed blood transfusion and 11 (11.5%) in the standard approach group (p = .012). Pyrexia developed in 3 participants (3.1%) in the reverse breech extraction approach group, and 19 (19.8%) in the standard approach group (p = .0006). Wound infection occurred in 2 women (2.1%) in the reverse breech extraction approach group, and 12 (12.5%) in the standard approach group (p = .007). Apgar score extraction approach group, and 21 (21.9%) in the standard approach group (p = .015). In conclusion, reverse breech extraction in Caesarean section for obstructed labour is an effective and safe alternative to the standard approach of pushing the fetal head up through the vagina.

  13. Tilting Uranus without a Collision

    Science.gov (United States)

    Rogoszinski, Zeeve; Hamilton, Douglas P.

    2016-10-01

    The most accepted hypothesis for the origin of Uranus' 98° obliquity is a giant collision during the late stages of planetary accretion. This model requires a single Earth mass object striking Uranus at high latitudes; such events occur with a probability of about 10%. Alternatively, Uranus' obliquity may have arisen from a sequence of smaller impactors which lead to a uniform distribution of obliquities. Here we explore a third model for tilting Uranus using secular spin-orbit resonance theory. We investigate early Solar System configurations in which a secular resonance between Uranus' axial precession frequency and another planet's orbital node precession frequency might occur.Thommes et al. (1999) hypothesized that Uranus and Neptune initially formed between Jupiter and Saturn, and were then kicked outward. In our scenario, Neptune leaves first while Uranus remains behind. As an exterior Neptune slowly migrates outward, it picks up both Uranus and Saturn in spin-orbit resonances (Ward and Hamilton 2004; Hamilton and Ward 2004). Only a distant Neptune has a nodal frequency slow enough to resonate with Uranus' axial precession.This scenario, with diverging orbits, results in resonance capture. As Neptune migrates outward its nodal precession slows. While in resonance, Uranus and Saturn each tilt a bit further, slowing their axial precession rates to continually match Neptune's nodal precession rate. Tilting Uranus to high obliquities takes a few 100 Myrs. This timescale may be too long to hold Uranus captive between Jupiter and Saturn, and we are investigating how to reduce it. We also find that resonance capture is rare if Uranus' initial obliquity is greater than about 10°, as the probability of capture decreases as the planet's initial obliquity increases. We will refine this estimate by quantifying capture statistics, and running accretion simulations to test the likelihood of a low early obliquity. Our preliminary findings show that most assumptions about

  14. Modeling of Tilting-Pad Journal Bearings with Transfer Functions

    Directory of Open Access Journals (Sweden)

    J. A. Vázquez

    2001-01-01

    Full Text Available Tilting-pad journal bearings are widely used to promote stability in modern rotating machinery. However, the dynamics associated with pad motion alters this stabilizing capacity depending on the operating speed of the machine and the bearing geometric parameters, particularly the bearing preload. In modeling the dynamics of the entire rotor-bearing system, the rotor is augmented with a model of the bearings. This model may explicitly include the pad degrees of freedom or may implicitly include them by using dynamic matrix reduction methods. The dynamic reduction models may be represented as a set of polynomials in the eigenvalues of the system used to determine stability. All tilting-pad bearings can then be represented by a fixed size matrix with polynomial elements interacting with the rotor. This paper presents a procedure to calculate the coefficients of polynomials for implicit bearing models. The order of the polynomials changes to reflect the number of pads in the bearings. This results in a very compact and computationally efficient method for fully including the dynamics of tilting-pad bearings or other multiple degrees of freedom components that interact with rotors. The fixed size of the dynamic reduction matrices permits the method to be easily incorporated into rotor dynamic stability codes. A recursive algorithm is developed and presented for calculating the coefficients of the polynomials. The method is applied to stability calculations for a model of a typical industrial compressor.

  15. Tilted Foils Nuclear Spin Polarization at REX-ISOLDE

    CERN Document Server

    Törnqvist, Hans Toshihide

    2013-08-08

    This thesis will explain and summarize my work and involvement in experiments aimed at producing nuclear spin polarization of post-accelerated beams of ions with the tilted-foils technique at the REX-ISOLDE linear accelerator at CERN. Polarizing the nuclear spin of radioactive beams in particular may provide access to observables which may be difficult to obtain otherwise. Currently, the techniques commonly employed for nuclear spin polarization are restricted to specific nuclides and experimental measurement techniques. Tilted foils polarization may provide a new tool to extend the range of nuclides that can be polarized and the types of experiments that can be performed. The experiments rely not only on the production but also on the method to measure the degree of attained polarization. Two methods will be treated, based on particle scattering in Coulomb excitation that may be utilized for stable beams, and the $\\beta$-NMR that requires $\\beta$-decaying nuclei. The experimental setups and measurements will...

  16. Large optics inspection, tilting, and washing stand

    Science.gov (United States)

    Ayers, Marion Jay; Ayers, Shannon Lee

    2010-08-24

    A large optics stand provides a risk free means of safely tilting large optics with ease and a method of safely tilting large optics with ease. The optics are supported in the horizontal position by pads. In the vertical plane the optics are supported by saddles that evenly distribute the optics weight over a large area.

  17. Investigation of fiber tilt in paperboard

    Science.gov (United States)

    John M. Considine; David W. Vahey

    2008-01-01

    The introduction of short, tilted rods to reinforce polymer composite laminates has resulted in near doubling the strength of lap shear specimens. Paperboard is predominantly a multi-layered structure, similar to composite laminates in many ways. Improved bonding between layers should have a positive influence on mechanical performance. Tilted fibers, or z-direction...

  18. Microvascular responses to body tilt in cutaneous maximus muscle of conscious rats

    Science.gov (United States)

    Puri, Rohit K.; Segal, Steven S.

    1994-01-01

    We investigated microvascular responses to head-up tilt (HUT) and head-down tilt (HDT) in striated muscle of conscious male rats. To observe the microcirculation in the cutaneous maximus muscle, a transparent polycarbonate chamber was implanted aseptically into a skin fold created between the shoulders. Rats were trained to sit quietly during HUT and HDT while positioned on a horizontal microscope that rotated in the sagittal plane. At 4-5 days after surgery, arteriole and venule diameters were recorded using videomicroscopy while the rat experienced 10 min each (in random order) of HUT or HDT at 20 deg or 40 deg separated by 2-h rest periods. HUT had no affect on microvessel diameter; 20 deg HDT had little affect. In response to 40 deg HDT, 'large' arterioles constricted by 18 +/- 2% and 'small' arterioles dilated by 21 +/- 3%; this difference suggested variation in mechanisms controlling arteriolar responses. Venules exhibited a larger fluctuation in diameter during 40 deg HDT compared with other body positions, suggesting that venomotor activity may be induced with sufficient fluid shift or change in central venous pressure. These observations illustrate a viable model for studying microvascular responses to gravitational stress in conscious rats.

  19. A blended wing body airplane with a close-coupled, tilting tail

    Science.gov (United States)

    Nasir, R. E. M.; Mazlan, N. S. C.; Ali, Z. M.; Wisnoe, W.; Kuntjoro, W.

    2016-10-01

    This paper highlights a novel approach to stabilizing and controlling pitch and yaw motion via a set of horizontal tail that can act as elevator and rudder. The tail is incorporated into a new design of blended wing body (BWB) aircraft, known as Baseline-V, located just aft of the trailing edge of its inboard wing. The proposed close-coupled tail is equipped with elevators that deflect in unison, and can tilt - an unusual means of tilting where if starboard side is tilted downward at k degree, and then the portside must be tilted upward at k degree too. A wind tunnel experiment is conducted to investigate aerodynamics and static stability of Baseline-V BWB aircraft. The model is being tested at actual flight speed of 15 m/s (54 km/h) with varying angle of attack for five elevator angle cases at zero tilt angle and varying sideslip angle for four tilt angle cases at one fixed elevator angle. The result shows that the aircraft's highest lift-to-drag ratio is 32. It is also found that Baseline-V is statically stable in pitch and yaw but has no clear indication in terms of roll stability.

  20. Study of mine stability using records of ground tilting

    CSIR Research Space (South Africa)

    Spottiswoode, SM

    2006-06-01

    Full Text Available to estimate tilting from mining, assuming elastic rock mass behaviour. Some suggestions for further work are made. These include studying changes in a seismic tilting following tilt events associated with shrinking pillars. This might provide more direct...

  1. Evaluating Tilt for Wind Farms: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Annoni, Jennifer; Scholbrock, Andrew; Churchfield, Matthew; Fleming, Paul

    2017-06-29

    The objective of this work is to demonstrate the feasibility of tilt in a wind plant. Tilt control, much like other wind plant control strategies, has the potential to improve the performance of a wind plant. Tilt control uses the tilt angle of the turbine to direct the wake above or below the downstream turbines. This paper presents a study of tilt in two- and threeturbine arrays. Specifically, the authors show that the power production of a two-turbine array can be increased by tilting turbines in a specific orientation. When adding more turbines, as is shown with the three-turbine array, the overall percentage of power gain increases. This outcome deviates from some of the results seen in typical wind plant control strategies. Finally, we discuss the impact this type of control strategy has on the aerodynamics in a wind plant. This analysis demonstrates that a good understanding of wake characteristics is necessary to improve the plant's performance. A tilt strategy such as the one presented in this paper may have implications for future control/optimization studies including optimization of hub heights in a wind plant and analysis of deep array effects.

  2. Tilting mutation of Brauer tree algebras

    CERN Document Server

    Aihara, T

    2010-01-01

    We define tilting mutations of symmetric algebras as the endomorphism algebras of Okuyama-Rickard complexes. For Brauer tree algebras, we give an explicit description of the change of Brauer trees under mutation.

  3. Aurelia aurita bio-inspired tilt sensor

    Science.gov (United States)

    Smith, Colin; Villanueva, Alex; Priya, Shashank

    2012-10-01

    The quickly expanding field of mobile robots, unmanned underwater vehicles, and micro-air vehicles urgently needs a cheap and effective means for measuring vehicle inclination. Commonly, tilt or inclination has been mathematically derived from accelerometers; however, there is inherent error in any indirect measurement. This paper reports a bio-inspired tilt sensor that mimics the natural balance organ of jellyfish, called the ‘statocyst’. Biological statocysts from the species Aurelia aurita were characterized by scanning electron microscopy to investigate the morphology and size of the natural sensor. An artificial tilt sensor was then developed by using printed electronics that incorporates a novel voltage divider concept in conjunction with small surface mount devices. This sensor was found to have minimum sensitivity of 4.21° with a standard deviation of 1.77°. These results open the possibility of developing elegant tilt sensor architecture for both air and water based platforms.

  4. Tilting Shear Layers in Coastal Flows

    Science.gov (United States)

    2015-09-30

    2181 email: khelfrich@whoi.edu Brian L. White Department of Marine Sciences University of North Carolina at Chapel Hill 3117c Venable Hall ...and rotation. Figure 1. a) Sketch of tilting, horizontal shear layer near Stuart Island from Farmer et al (2002). b) Photograph of the...surface expression of intense vortices near Stuart Island (from Farmer et al, 2002). c) Infra-red image of a tilting shear layer in the Snohomish River

  5. The tilt illusion: phenomenology and functional implications.

    Science.gov (United States)

    Clifford, Colin W G

    2014-11-01

    The perceived orientation of a line or grating is affected by the orientation structure of the surrounding image: the tilt illusion. Here, I offer a selective review of the literature on the tilt illusion, focusing on functional aspects. The review explores the merits of mechanistic accounts of the tilt illusion based upon sensory gain control in which neuronal responses are normalized by the pooled activity of other units. The role of inhibition between orientation-selective neurons is discussed, and it is argued that their associated disinhibition must also be taken into account in order to model the full angular dependence of the tilt illusion on surround orientation. Parallels are drawn with adaptation as modulation by the temporal rather than spatial context within which an image fragment is processed. The chromatic selectivity of the tilt illusion and the extent of its dependence on the visibility of the surround are used to infer characteristics of the neuronal normalization pools and the loci in the cortical processing hierarchy at which gain control operates. Finally, recent evidence is discussed as to the possible clinical relevance of the tilt illusion as a biomarker for schizophrenia.

  6. Keblish's lateral surgical approach enhances patellar tilt in valgus knee arthroplasty

    Directory of Open Access Journals (Sweden)

    José Roberto Tonelli Filho

    Full Text Available ABSTRACT OBJECTIVE: To compare the clinical and radiological outcomes of conventional medial and lateral approaches for total knee replacement in the valgus osteoarthritic knee. METHODS: In this randomized controlled trial, 21 patients with valgus knee osteoarthritis were randomized to total knee replacement through medial or lateral approach. The primary outcome was radiographic patellar tilt. Secondary outcomes were visual analog scale of pain, postoperative levels of hemoglobin, and clinical aspect of the operative wound. RESULTS: There were no differences between the groups regarding other clinical variables. Mean lateral tilt of the patella was 3.1 degrees (SD ± 5.3 in the lateral approach group and 18 degrees (SD ± 10.2 in the medial approach group (p = 0.02. There were no differences regarding the secondary outcomes. CONCLUSION: Lateral approach provided better patellar tilt following total knee replacement in valgus osteoarthritic knee.

  7. Tilted wheel satellite attitude control with air-bearing table experimental results

    Science.gov (United States)

    Inumoh, Lawrence O.; Forshaw, Jason L.; Horri, Nadjim M.

    2015-12-01

    Gyroscopic actuators for satellite control have attracted significant research interest over the years, but their viability for the control of small satellites has only recently started to become clear. Research on variable speed gyroscopic actuators has long been focused on single gimbal actuators; double gimbal actuators typically operate at constant wheel spin rate and allow tilt angle ranges far larger than the ranges needed to operate most satellite missions. This research examines a tilted wheel, a newly proposed type of inertial actuator that can generate torques in all three principal axes of a rigid satellite using a spinning wheel and a double tilt mechanism. The tilt mechanism tilts the angular momentum vector about two axes providing two degree of freedom control, while variation of the wheel speed provides the third. The equations of motion of the system lead to a singularity-free system during nominal operation avoiding the need for complex steering logic. This paper describes the hardware design of the tilted wheel and the experimental setup behind both standalone and spherical air-bearing tables used to test it. Experimental results from the air bearing table are provided with the results depicting the high performance capabilities of the proposed actuator in torque generation.

  8. Does an Average White Dwarf Have Enough Mass to Prevent an Accretion Disk Tilt?

    CERN Document Server

    Montgomery, M M

    2010-01-01

    In a recent publication, we introduce the lift force as a common source to accretion disk tilt that is likely relevant to accretion disk systems. Lift is generated by slightly different supersonic gas stream speeds flowing over and under the disk at the bright spot. In this conference proceeding, we focus on whether the average white dwarf has enough mass to prevent a disk tilt in non-magnetic Cataclysmic Variables (CVs) with accretion disks. Assuming a white dwarf mass of 0.6M$_{\\odot}$ and a disk mass of 10$^{-11}$M$_{\\odot}$, we vary the secondary mass to establish theoretical minimum mass transfer rates needed to induce and maintain a disk tilt of four degrees around the line of nodes. For mass ratios in the range \\( (0.13 \\le q=M_{2}M^{-1} \\le 0.45) \\), we confirm that the secondary mass does not contribute significantly to disk tilt. We also confirm that the average white dwarf does not have enough mass to prevent a disk tilt. We find that disk tilt may be likely in low mass transfer rate systems such a...

  9. CONTRIBUTION OF QUADRATIC RESIDUE DIFFUSERS TO EFFICIENCY OF TILTED PROFILE PARALLEL HIGHWAY NOISE BARRIERS

    Directory of Open Access Journals (Sweden)

    M. R. Monazzam ، P. Nassiri

    2009-10-01

    Full Text Available This paper presents the results of an investigation on the acoustic performance of tilted profile parallel barriers with quadratic residue diffuser (QRD tops and faces. A 2D boundary element method (BEM is used to predict the barrier insertion loss. The results of rigid and with absorptive coverage are also calculated for comparisons. Using QRD on the top surface and faces of all tilted profile parallel barrier models introduced here is found to improve the efficiency of barriers compared with rigid equivalent parallel barrier at the examined receiver positions. Applying a QRD with frequency design of 400 Hz on 5 degrees tilted parallel barrier improves the overall performance of its equivalent rigid barrier by 1.8 dB(A. Increase in the treated surfaces with reactive elements shifts the effective performance toward lower frequencies. It is found that by tilting the barriers from 0 to 10 degrees in parallel set up, the degradation effects in parallel barriers is reduced but the absorption effect of fibrous materials and also diffusivity of the quadratic residue diffuser is reduced significantly. In this case all the designed barriers have better performance with 10 degrees tilting in parallel set up. The most economic traffic noise parallel barrier which produces significantly high performance, is achieved by covering the top surface of the barrier closed to the receiver by just a QRD with frequency design of 400 Hz and tilting angle of 10 degrees. The average A-weighted insertion loss in this barrier is predicted to be 16.3 dB (A.

  10. Central venous oxygen saturation during hypovolaemic shock in humans

    DEFF Research Database (Denmark)

    Madsen, P; Iversen, H; Secher, N H

    1993-01-01

    We compared central venous oxygen saturation and central venous pressure (CVP) as indices of the effective blood volume during 50 degrees head-up tilt (anti-Trendelenburg's position) induced hypovolaemic shock in eight healthy subjects. Head-up tilt increased thoracic electrical impedance from 31...

  11. Tilting of posterior mandibular and maxillary implants for improved prosthesis support.

    Science.gov (United States)

    Krekmanov, L; Kahn, M; Rangert, B; Lindström, H

    2000-01-01

    Rehabilitation of atrophied edentulous arches with endosseous implants in the posterior regions is often associated with anatomic problems such as jaw shape and location of the mental loop, mandibular canal, and maxillary sinuses. The purpose of this investigation was to modify the method for implant placement in the posterior part of the jaws to extend fixed implant-connected prostheses further distally, and to reduce the length of cantilevers in complete-arch prostheses without transpositioning the mandibular nerve or performing bone grafting in the maxilla. Forty-seven consecutive patients were treated with implants (25 patients/36 mandibular implants, 22 patients/30 maxillary implants) placed in tilted positions. They were followed a mean of 40 months (mandibles) and 53 months (maxillae). In the mandible, implants close to the mental foramina were tilted posteriorly approximately 25 to 35 degrees. In the maxilla, the posterior implants were placed close to and parallel with the sinus walls and were titled anteriorly/posteriorly approximately 30 to 35 degrees. Patients gained a mean distance of 6.5 mm of prosthesis support in the mandible and 9.3 mm in the maxilla, as a result of implant tilting. There were no implant failures in mandibles. The cumulative success rates in the maxilla at 5 years were 98% for tilted implants and 93% for non-tilted implants. Paresthesias of the mental nerve were observed on 4 sides during the first 2 to 3 weeks after implant placement. Analysis of the load distribution in one mandibular case showed no significant difference between tilted and the non-tilted implants, and the improved prosthesis support was confirmed. Satisfactory medium-term results concerning osseointegration and significant extension of prosthesis support show that the method can be recommended. This technique may allow for longer implants to be placed with improved bone anchorage.

  12. Tilts of the Master Equatorial Tower

    Science.gov (United States)

    Ahlstrom, H. G., Jr.; Gawronski, W.; Girdner, D.; Noskoff, E.; Sommerville, J. N.

    2000-07-01

    At the center of the DSS-14 antenna, a tower reaches to the focal point of the antenna dish. The master equatorial (ME) instrument is located at the top of the tower. This instrument precisely (with an accuracy that exceeds that of the antenna) follows the commanded trajectory. Through the optical coupling, the antenna focal point follows the ME. One factor of the antenna pointing precision is the movement of the ME base, i.e., the top of the tower. For this reason, measurements of the ME tower tilts have been taken in order to quantify the tilts, to determine possible causes of the tilting, and to update the antenna pointing budget. They were conducted under three antenna operating modes: during tracking, slewing, and antenna stowing. The measurements indicate that the ME tower tilts introduce significant pointing errors that exceed the required 32-GHz (Ka-band) pointing precision (estimated as 0.8 mdeg for a 0.1-dB gain loss). Four different sources of tilt were identified and require verification.

  13. The functional benefits of tilt adaptation.

    Science.gov (United States)

    Kristjánsson, Árni

    2011-01-01

    Many have argued that effects of adaptation, such as aftereffects from motion or tilt, reflect that the visual system hones its responses in on the characteristics of the adapting stimulus. This view entails that on average, the discrimination of the characteristics of an adapting stimulus should become easier as viewing time increases since the variation in the response gradually adapts to the range and variation in the stimulus. Here this was tested for adaptation to tilt. Observers viewed a Gabor patch which varied in contrast from 0 to 74% at a rate of 0.6 Hz, for 4, 8, 16 or 32 s, after which the Gabor patch changed orientation (at the point when contrast was 0). The results show that the longer the observers adapt to the dynamic Gabor, the better they become at discriminating between clockwise (CW) or counterclockwise (CCW) changes in tilt (orientation) of the same patch. Experiment 2 confirms that both the direct and indirect tilt aftereffects are seen with this contrast varying Gabor patch and Experiment 3 shows that the aftereffects are only slightly smaller than in other studies with stimuli such as lines and sinusoidal gratings. These results show that adaptation to tilt leads to better discrimination around the orientation of the adapting stimulus itself, and that discrimination performance improves steadily with increased adaptation time. The results support proposals that the visual system adjusts its response characteristics to the properties of the visual input at a given time.

  14. Integrative advances for OCT-guided ophthalmic surgery and intraoperative OCT: microscope integration, surgical instrumentation, and heads-up display surgeon feedback.

    Directory of Open Access Journals (Sweden)

    Justis P Ehlers

    Full Text Available PURPOSE: To demonstrate key integrative advances in microscope-integrated intraoperative optical coherence tomography (iOCT technology that will facilitate adoption and utilization during ophthalmic surgery. METHODS: We developed a second-generation prototype microscope-integrated iOCT system that interfaces directly with a standard ophthalmic surgical microscope. Novel features for improved design and functionality included improved profile and ergonomics, as well as a tunable lens system for optimized image quality and heads-up display (HUD system for surgeon feedback. Novel material testing was performed for potential suitability for OCT-compatible instrumentation based on light scattering and transmission characteristics. Prototype surgical instruments were developed based on material testing and tested using the microscope-integrated iOCT system. Several surgical maneuvers were performed and imaged, and surgical motion visualization was evaluated with a unique scanning and image processing protocol. RESULTS: High-resolution images were successfully obtained with the microscope-integrated iOCT system with HUD feedback. Six semi-transparent materials were characterized to determine their attenuation coefficients and scatter density with an 830 nm OCT light source. Based on these optical properties, polycarbonate was selected as a material substrate for prototype instrument construction. A surgical pick, retinal forceps, and corneal needle were constructed with semi-transparent materials. Excellent visualization of both the underlying tissues and surgical instrument were achieved on OCT cross-section. Using model eyes, various surgical maneuvers were visualized, including membrane peeling, vessel manipulation, cannulation of the subretinal space, subretinal intraocular foreign body removal, and corneal penetration. CONCLUSIONS: Significant iterative improvements in integrative technology related to iOCT and ophthalmic surgery are demonstrated.

  15. Advances in tilt rotor noise prediction

    Science.gov (United States)

    George, A. R.; Coffen, C. D.; Ringler, T. D.

    The two most serious tilt rotor external noise problems, hover noise and blade-vortex interaction noise, are studied. The results of flow visualization and inflow velocity measurements document a complex, recirculating highly unsteady and turbulent flow due to the rotor-wing-body interactions characteristic of tilt rotors. The wing under the rotor is found to obstruct the inflow, causing a deficit in the inflow velocities over the inboard region of the rotor. Discrete frequency harmonic thickness and loading noise mechanisms in hover are examined by first modeling tilt rotor hover aerodynamics and then applying various noise prediction methods using the WOPWOP code. The analysis indicates that the partial ground plane created by the wing below the rotor results in a primary sound source for hover.

  16. A Construction of Characteristic Tilting Modules

    Institute of Scientific and Technical Information of China (English)

    DENG Bang Ming

    2002-01-01

    Associated with each finite directed quiver Q is a quasi-hereditary algebra, the so-calledtwisted double of the path algebra kQ. Characteristic tilting modules over this class of quasi-hereditaryalgebras are constructed. Their endomorphism algebras are explicitly described. It turns out that thisclass of quasi-hereditary algebras is closed under taking the Ringel dual.

  17. "Happiness and Education": Tilting at Windmills?

    Science.gov (United States)

    Verducci, Susan

    2013-01-01

    This essay explores the question: Is Nel Noddings a visionary who sees past the constraints of contemporary education or is she, like Don Quixote, madly tilting at windmills in her description and defense of happiness as an educational aim? Viewing the educational aim of happiness as an ideal raises substantial challenges for the practicality of…

  18. "Happiness and Education": Tilting at Windmills?

    Science.gov (United States)

    Verducci, Susan

    2013-01-01

    This essay explores the question: Is Nel Noddings a visionary who sees past the constraints of contemporary education or is she, like Don Quixote, madly tilting at windmills in her description and defense of happiness as an educational aim? Viewing the educational aim of happiness as an ideal raises substantial challenges for the practicality of…

  19. Listening talkers produce great spectral tilt contrasts

    DEFF Research Database (Denmark)

    Christiansen, Thomas Ulrich; Heegård, Jan; Henrichsen, Peter Juel

    of colored geometrical shapes taken from DanPASS [2]. The spectral tilt was gauged by calculating the band-level difference in dB between two frequency bands with pass-bands 150 to 803 Hz and 803 to 1358 Hz respectively in 5 ms intervals. This was done separately for intervals containing content words...

  20. Comparison of Indiana High School Football Injury Rates by Inclusion of the USA Football “Heads Up Football” Player Safety Coach

    Science.gov (United States)

    Kerr, Zachary Y.; Dalton, Sara L.; Roos, Karen G.; Djoko, Aristarque; Phelps, Jennifer; Dompier, Thomas P.

    2016-01-01

    Background: In Indiana, high school football coaches are required to complete a coaching education course with material related to concussion awareness, equipment fitting, heat emergency preparedness, and proper technique. Some high schools have also opted to implement a player safety coach (PSC). The PSC, an integral component of USA Football’s Heads Up Football (HUF) program, is a coach whose primary responsibility is to ensure that other coaches are implementing proper tackling and blocking techniques alongside other components of the HUF program. Purpose: To compare injury rates in Indiana high school football teams by their usage of a PSC or online coaching education only. Study Design: Cohort study; Level of evidence, 2. Methods: Athletic trainers (ATs) evaluated and tracked injuries at each practice and game during the 2015 high school football season. Players were drawn from 6 teams in Indiana. The PSC group, which used the PSC component, was comprised of 204 players from 3 teams. The “education only” group (EDU), which utilized coaching education only, was composed of 186 players from 3 teams. Injury rates and injury rate ratios (IRRs) were reported with 95% confidence intervals (CIs). Results: During 25,938 athlete-exposures (AEs), a total of 149 injuries were reported, of which 54 (36.2%) and 95 (63.8%) originated from the PSC and EDU groups, respectively. The practice injury rate was lower in the PSC group than the EDU group (2.99 vs 4.83/1000 AEs; IRR, 0.62; 95% CI, 0.40-0.95). The game injury rate was also lower in the PSC group than the EDU group (11.37 vs 26.37/1000 AEs; IRR, 0.43; 95% CI, 0.25-0.74). When restricted to concussions only, the rate was lower in the PSC group (0.09 vs 0.73/1000 AEs; IRR, 0.12; 95% CI, 0.01-0.94), although only 1 concussion was reported in the PSC group. No differences were found in game concussion rates (0.60 vs 4.39/1000 AEs; IRR, 0.14; 95% CI, 0.02-1.11). Conclusion: Findings support the PSC as an effective

  1. Tilt Angle and Footpoint Separation of Small and Large Bipolar Sunspot Regions Observed with HMI

    CERN Document Server

    McClintock, Bruce H

    2016-01-01

    We investigate bipolar sunspot regions and how tilt angle and footpoint separation vary during emergence and decay. The Helioseismic and Magnetic Imager on board the Solar Dynamic Observatory collects data at a higher cadence than historical records and allows for a detailed analysis of regions over their lifetimes. We sample the umbral tilt angle, footpoint separation, and umbral area of 235 bipolar sunspot regions in Helioseismic and Magnetic Imager - Debrecen Data (HMIDD) with an hourly cadence. We use the time when the umbral area peaks as time zero to distinguish between the emergence and decay periods of each region and we limit our analysis of tilt and separation behavior over time to within +/-96 hours of time zero. Tilt angle evolution is distinctly different for regions with small (~30 MSH), midsize (~50 MSH), and large (~110 MSH) maximum umbral areas, with 45 and 90 MSH being useful divisions in separating the groups. At the peak umbral area, we determine median tilt angles for small (7.6 degrees),...

  2. Connections Between Tilted Accretion Disks Around White Dwarfs and Substellar Companions

    CERN Document Server

    Montgomery, M M

    2010-01-01

    Accretion disks in white dwarf systems are believed to be tilted. In a recent publication, the lift force has been suggested to be a source to disk tilt, a source that is likely relevant to all accretion disk systems. Lift is generated by slightly different supersonic gas stream speeds flowing over and under the disk at the bright spot. In this conference proceeding, we focus on whether a brown dwarf donor star accreting onto a white dwarf primary has enough mass to contribute to disk tilt. We also would like to obtain whether a white dwarf - brown dwarf close binary system has enough mass to induce and maintain a disk tilt of four degrees. We adopt SDSS 103533.03+055158.4 as our model system which has a mass transfer rate of \\( (10\\pm2) \\times 10^{-12} \\) M$_{\\odot}$ yr$^{-1}$. We find that the brown dwarf in SDSS 1035 does not have enough mass to contribute to disk tilt. We find a gross magnitude of the minimum mass transfer rate to be $\\sim10^{-10}$M$_{\\odot}$yr$^{-1}$. We conclude that SDSS 1035 does not ...

  3. Connections between Tilted Accretion Disks around White Dwarfs and Substellar Companions

    CERN Document Server

    Montgomery, M M

    2011-01-01

    Accretion disks in white dwarf systems are believed to be tilted. In a recent publication, the lift force has been suggested to be a source to disk tilt, a source that is likely relevant to all accretion disk systems. Lift is generated by slightly different supersonic gas stream speeds flowing over and under the disk at the bright spot. In this conference proceeding, we focus on whether a brown dwarf donor star accreting onto a white dwarf primary has enough mass to contribute to disk tilt. We also would like to obtain whether a white dwarf - brown dwarf close binary system has enough mass to induce and maintain a disk tilt of four degrees. We adopt SDSS 103533.03+055158.4 as our model system which has a mass transfer rate of (10 \\pm 2) x 10-12 M* yr-1. We find that the brown dwarf in SDSS 1035 does not have enough mass to contribute to disk tilt. We find a gross magnitude of the minimum mass transfer rate to be - 10-10 M* yr-1 . We conclude that SDSS 1035 does not seem to have a high enough mass transfer rat...

  4. Characterizing local variability in long‐period horizontal tilt noise

    Science.gov (United States)

    Rohde, M.D.; Ringler, Adam; Hutt, Charles R.; Wilson, David; Holland, Austin; Sandoval, L.D; Storm, Tyler

    2017-01-01

    Horizontal seismic data are dominated by atmospherically induced tilt noise at long periods (i.e., 30 s and greater). Tilt noise limits our ability to use horizontal data for sensitive seismological studies such as observing free earth modes. To better understand the local spatial variability of long‐period horizontal noise, we observe horizontal noise during quiet time periods in the Albuquerque Seismological Laboratory (ASL) underground vault using four small‐aperture array configurations. Each array comprises eight Streckeisen STS‐2 broadband seismometers. We analyze the spectral content of the data using power spectral density and magnitude‐squared coherence (γ2‐coherence). Our results show a high degree of spatial variability and frequency dependence in the long‐period horizontal wavefield. The variable nature of long‐period horizontal noise in the ASL vault suggests that it might be highly local in nature and not easily characterized by simple physical models when overall noise levels are low, making it difficult to identify locations in the vault with lower horizontal noise. This variability could be limiting our ability to apply coherence analysis for estimating horizontal sensor self‐noise and could also complicate various indirect methods for removing long‐period horizontal noise (e.g., collocated rotational sensor or microbarograph).

  5. A computer simulation study of tilted smectic mesophases

    Energy Technology Data Exchange (ETDEWEB)

    Withers, I.M

    2000-05-01

    Results are presented from a series of simulations undertaken to determine the effect of a novel form of molecular biaxiality upon the phase behaviour of the well established Gay-Berne (GB) liquid crystal model. Firstly, the simulation of a bulk system interacting via the Internally-Rotated Gay Berne (IRGB) potential, which offers a single-site representation of a molecule rigidly constrained into a zig-zag conformation, is presented. The results of simulations performed for systems of IRGB particles with an aspect ratio of 3:1 confirm that the introduction of biaxiality into the model results in the destabilisation of the orientationally ordered phases. For particles with a sufficiently pronounced zig-zag conformation, this results in the complete destabilisation of the smectic A phase and the smectic B phase being replaced by the tilted smectic J phase. Following these observations, the effect upon the phase behaviour of increasing molecular elongation is also considered, with an increase in the aspect ratio from 3:1 to 4:1 resulting in the nematic and smectic J phases being replaced by smectic A and smectic G phases respectively. Secondly, a version of the IRGB potential modified to include a degree of molecular flexibility is considered. Results obtained from bulk systems interacting via the flexible IRGB for 3:1 and 4:1 molecules show that the introduction of flexibility results in the destabilisation of the smectic A phase and the stabilisation of the nematic and tilted hexatic phases. Finally, the effect upon the phase behaviour of the rigid IRGB model of the inclusion of a longitudinal linear quadrupole is examined. These results show that increasing quadrupole moment results in the destabilisation of the tilted hexatic phase, although the biaxial order parameter is increased with increasing quadrupole moment. There is no clear correlation between quadrupole magnitude and the other observed phase transitions, with the nematic and smectic A phases being

  6. determination of determination of optimal tilt angle for maximum ...

    African Journals Online (AJOL)

    eobe

    Keywords: Energy output, photovoltaic module, best tilt angle, solar radiation, sunshine hours, ambient temperature. 1. .... at any given time is vital in the design of a PV system. ..... Panels at Different Temperatures and Tilt Angles,”. ISESCO ...

  7. The Tilt between Acretion Disk and Stellar Disk

    Indian Academy of Sciences (India)

    Shiyin Shen; Zhengyi Shao; Minfeng Gu

    2011-03-01

    The orientations of the accretion disk of active galactic nuclei (AGN) and the stellar disk of its host galaxy are both determined by the angular momentum of their forming gas, but on very different physical environments and spatial scales. Here we show the evidence that the orientation of the stellar disk is correlated with the accretion disk by comparing the inclinations of the stellar disks of a large sample of Type 2 AGNs selected from Sloan Digital Sky Survey (SDSS, York et al. 2000) to a control galaxy sample. Given that the Type 2 AGN fraction is in the range of 70–90 percent for low luminosity AGNs as a priori, we find that the mean tilt between the accretion disk and stellar disk is ∼ 30 degrees (Shen et al. 2010).

  8. Flight test evaluations of the head-up display and the inertial reference unit of the NAL QSTOL experimental aircraft (Aska) by the NAL B-65 Queen Air research aircraft. Teisoon STOL jikkenkiyo HUD (head up display) oyobi IRU (kansei kijun sochi) no hiko hyoka shiken

    Energy Technology Data Exchange (ETDEWEB)

    1993-07-01

    A head-up display (HUD) and an inertial reference unit (IRU) were developed by the National Aerospace Laboratory (NAL) for the NAL QSTOL (Quiet Short Take Off and Landing) experimental air craft (Aska). In order to evaluate both the performance of the HUD which provides the pilot with landing aid information, and the accuracy and characteristics of the IRU to be used for flight control and measurements, flight tests were conducted on board the B-65 Queen Air research aircraft. The results indicated that the characteristics of the HUD as an approach and landing aid system were good, and also that the IRU was useful as a sensor for flight control and measurements. Furthermore, it was shown that fundamental methods of evaluating the HUD characteristics and the IRU accuracy in actual flight were established for application of the HUD and the IRU to a new aircraft in the future. In addition, possibility of a new technology with landing aid information by means of the HUD was made clear. 21 refs., 48 figs., 14 tabs.

  9. A tilted transversely isotropic slowness surface approximation

    KAUST Repository

    Stovas, A.

    2012-05-09

    The relation between vertical and horizontal slownesses, better known as the dispersion relation, for transversely isotropic media with a tilted symmetry axis (TTI) requires solving a quartic polynomial equation, which does not admit a practical explicit solution to be used, for example, in downward continuation. Using a combination of the perturbation theory with respect to the anelliptic parameter and Shanks transform to improve the accuracy of the expansion, we develop an explicit formula for the vertical slowness that is highly accurate for all practical purposes. It also reveals some insights into the anisotropy parameter dependency of the dispersion relation including the low impact that the anelliptic parameter has on the vertical placement of reflectors for a small tilt in the symmetry angle. © 2012 European Association of Geoscientists & Engineers.

  10. Ram pressure stripping of tilted galaxies

    CERN Document Server

    Jachym, P; Palous, J; Combes, F

    2009-01-01

    Ram pressure stripping of galaxies in clusters can yield gas deficient disks. Previous numerical simulations based on various approaches suggested that, except for near edge-on disk orientations, the amount of stripping depends very little on the inclination angle. Following our previous study of face-on stripping, we extend the set of parameters with the disk tilt angle and explore in detail the effects of the ram pressure on the interstellar content (ISM) of tilted galaxies that orbit in various environments of clusters, with compact or extended distributions of the intra-cluster medium (ICM). We further study how results of numerical simulations could be estimated analytically. A grid of numerical simulations with varying parameters is produced using the tree/SPH code GADGET with a modified method for calculating the ISM-ICM interaction. These SPH calculations extend the set of existing results obtained from different codes using various numerical techniques. The simulations confirm the general trend of le...

  11. Estimating Insolation Incident on Tilted Surfaces

    Science.gov (United States)

    Elkin, R. E.; Toelle, R. G.

    1983-01-01

    ASHMET computer program estimates amount of solar insolation incident on surfaces of several types of solar collectors, including fixed-position flat-plate, monthly-tilt-adjusted flat-plat, beam-tracting, and fixed-azimuthtracker. Basic methodology employed in ASHMET is to use ASHRAE relationships to obtain clear-day total daily insolation incident on collector surface of representative day of each month of year. ASHMET is interactive program and prompts user for all required data.

  12. Dry tilt network at Mount Rainier, Washington

    Science.gov (United States)

    Dzurisin, Daniel; Johnson, Daniel J.; Symonds, R.B.

    1984-01-01

    In addition to its primary responsibility of monitoring active Mount St. Helens, the David A. Johnston Cascades Volcano Observatory (CVO) has been charged with obtaining baseline geodetic and geochemical information at each of the other potentially active Cascade volcanoes. Dry tilt and/or trilateration networks were established during 1975-82 at Mount Baker, Mount St. Helens, Mount Hood, Mount Shasta, Lassen Peak, Crater Lake, and Long Valley caldera; coverage was extended during September 1982 to include Mount Rainier.

  13. Tilt, Warp, and Simultaneous Precessions in Disks

    CERN Document Server

    Montgomery, M M

    2012-01-01

    Warps are suspected in disks around massive compact objects. However, the proposed warping source -- non-axisymmetric radiation pressure -- does not apply to white dwarfs. In this letter we report the first Smoothed Particle Hydrodynamic simulations of accretion disks in SU UMa-type systems that naturally tilt, warp, and simultaneously precess in the prograde and retrograde directions using white dwarf V344 Lyrae in the Kepler field as our model. After ~79 days in V344 Lyrae, the disk angular momentum L_d becomes misaligned to the orbital angular momentum L_o. As the gas stream remains normal to L_o, hydrodynamics (e.g., the lift force) is a likely source to disk tilt. In addition to tilt, the outer disk annuli cyclically change shape from circular to highly eccentric due to tidal torques by the secondary star. The effect of simultaneous prograde and retrograde precession is a warp of the colder, denser midplane as seen along the disk rim. The simulated rate of apsidal advance to nodal regression per orbit ne...

  14. Tilting of a Disk of Gravitating Rings

    CERN Document Server

    Lovelace, R V E

    1997-01-01

    The present work represents an attempt to understand the `rules of behavior' of observed warps in the HI disks of spiral galaxies found by Briggs (1990). In contrast with most earlier theoretical work, the present study investigates different initial value problems of a warped disk in an oblate (or prolate) halo potential, and it represents the disk warp in terms of $N$ independently tilted, self-gravitating, concentric rings. This representation gives new insight into the disk warping. A new constant of the motion of $N$ tilted rings is identified (in addition to the energy). The phenomenon of phase-locking of the lines-of-nodes of nearby rings due to self-gravity is demonstrated. We consider the influence of dynamical friction due to ring motion through the halo matter as well as friction between gaseous rings with different vertical motions due to turbulent viscosity. We first consider the dynamics of one, two, and three tilted rings of different radii in a halo potential. We go on to develop dynamical equ...

  15. WIYN tip-tilt module performance

    Science.gov (United States)

    Claver, Charles F.; Corson, Charles; Gomez, R. Richard, Jr.; Daly, Philip N.; Dryden, David M.; Abareshi, Behzod

    2003-02-01

    The WIYN Tip-Tilt Module (WTTM) is an addition to the existing Instrument Adapter System (IAS) providing a high performance optical-NIR image stabilized port on the WIYN 3.5m telescope. The WTTM optical system uses a 3-mirror off-axis design along with a high bandwidth tilt mirror. The WTTM is a reimaging system with 15% magnification producing a 4x4 arcminute field of view and near diffraction limited imagery from 400-2000nm. The optics are diamond turned in electroless Nickel over an Aluminum substrate. The WTTM opto-mechanical assembly was designed and built using the principals of the "build-to-print" technique, where the entire system is fabricated and assembled to tolerance with no adjustments. A unique high performance error sensor, using an internal mirrorlette array that feeds 4 fiber coupled avalanche photodiode photon counters, provides the tilt signal. The system runs under the Real-Time Linux operating system providing a maximum closed loop rate of 3khz. In this paper we report on the successful lab testing, verification of the "build-to-print" technique and on telescope performance of the WTTM.

  16. Introducer Curving Technique for the Prevention of Tilting of Transfemoral Gunther Tulip Inferior Vena Cava Filter

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Liang; Shen, Jing; Tong, Jia Jie [The First Hospital of China Medical University, Shenyang (China); Huang, De Sheng [College of Basic Medical Science, China Medical University, Shenyang (China)

    2012-07-15

    To determine whether the introducer curving technique is useful in decreasing the degree of tilting of transfemoral Tulip filters. The study sample group consisted of 108 patients with deep vein thrombosis who were enrolled and planned to undergo thrombolysis, and who accepted transfemoral Tulip filter insertion procedure. The patients were randomly divided into Group C and Group T. The introducer curving technique was Adopted in Group T. The post-implantation filter tilting angle (ACF) was measured in an anteroposterior projection. The retrieval hook adhering to the vascular wall was measured via tangential cavogram during retrieval. The overall average ACF was 5.8 {+-} 4.14 degrees. In Group C, the average ACF was 7.1 {+-} 4.52 degrees. In Group T, the average ACF was 4.4 {+-} 3.20 degrees. The groups displayed a statistically significant difference (t = 3.573, p = 0.001) in ACF. Additionally, the difference of ACF between the left and right approaches turned out to be statistically significant (7.1 {+-} 4.59 vs. 5.1 {+-} 3.82, t = 2.301, p = 0.023). The proportion of severe tilt (ACF {>=} 10 degree) in Group T was significantly lower than that in Group C (9.3% vs. 24.1%, X{sup 2} = 4.267, p = 0.039). Between the groups, the difference in the rate of the retrieval hook adhering to the vascular wall was also statistically significant (2.9% vs. 24.2%, X{sup 2} = 5.030, p = 0.025). The introducer curving technique appears to minimize the incidence and extent of transfemoral Tulip filter tilting.

  17. Simultaneous determination of sample thickness, tilt, and electron mean free path using tomographic tilt images based on Beer-Lambert law

    Science.gov (United States)

    Yan, Rui; Edwards, Thomas J.; Pankratz, Logan M.; Kuhn, Richard J.; Lanman, Jason K.; Liu, Jun; Jiang, Wen

    2015-01-01

    Cryo-electron tomography (cryo-ET) is an emerging technique that can elucidate the architecture of macromolecular complexes and cellular ultrastructure in a near-native state. Some important sample parameters, such as thickness and tilt, are needed for 3-D reconstruction. However, these parameters can currently only be determined using trial 3-D reconstructions. Accurate electron mean free path plays a significant role in modeling image formation process essential for simulation of electron microscopy images and model-based iterative 3-D reconstruction methods; however, their values are voltage and sample dependent and have only been experimentally measured for a limited number of sample conditions. Here, we report a computational method, tomoThickness, based on the Beer-Lambert law, to simultaneously determine the sample thickness, tilt and electron inelastic mean free path by solving an overdetermined nonlinear least square optimization problem utilizing the strong constraints of tilt relationships. The method has been extensively tested with both stained and cryo datasets. The fitted electron mean free paths are consistent with reported experimental measurements. The accurate thickness estimation eliminates the need for a generous assignment of Z-dimension size of the tomogram. Interestingly, we have also found that nearly all samples are a few degrees tilted relative to the electron beam. Compensation of the intrinsic sample tilt can result in horizontal structure and reduced Z-dimension of tomograms. Our fast, pre-reconstruction method can thus provide important sample parameters that can help improve performance of tomographic reconstruction of a wide range of samples. PMID:26433027

  18. Vertical Vergence Adaptation Produces an Objective Vertical Deviation That Changes With Head Tilt

    Science.gov (United States)

    Irsch, Kristina; Guyton, David L.; Ramey, Nicholas A.; Adyanthaya, Rohit S.; Ying, Howard S.

    2013-01-01

    Purpose. To document the cyclovertical ocular motor mechanism used for vertical fusion in healthy subjects, and to explore whether vertical vergence training in healthy individuals can produce objectively confirmed vertical deviations that change with head tilt, revealing a basic mechanism that can produce a pattern of misalignment in an otherwise normal ocular motor system that is similar to superior oblique muscle paresis (SOP). Methods. Seven subjects with normal orthoptic examinations were adapted to vertical image disparities using our tilting haploscopic eye-tracking apparatus presenting concentric circle targets without torsional cues. Static eye positions were recorded with head straight and when tilted 45 degrees to the left and right, during both binocular and monocular viewing. Results. Vertical fusional vergence was accompanied by a cycloversion, with the downward-moving eye intorting and the upward-moving eye extorting, implicating primary involvement of the oblique extraocular muscles. After adaptation to the slowly increasing vertical target separation, all subjects developed a temporary vertical deviation in the straight ahead position that increased with head tilt to one side and decreased with head tilt to the other side. Conclusions. These results not only show that head-tilt–dependent changes in vertical deviation are not necessarily pathognomonic for SOP, but also, and more importantly, suggest mechanisms that can mimic SOP and suggest a possible role for vertical vergence training in reducing deviations and thus the amount of head tilt required for fusion. Ultimately, vertical vergence training may provide an adjunct or alternative to extraocular muscle surgery in selected cases. PMID:23572100

  19. A new measurement for posterior tilt predicts reoperation in undisplaced femoral neck fractures: 113 consecutive patients treated by internal fixation and followed for 1 year

    DEFF Research Database (Denmark)

    Palm, Henrik; Gosvig, Kasper; Krasheninnikoff, Michael

    2009-01-01

    BACKGROUND AND PURPOSE: Preoperative posterior tilt in undisplaced (Garden I-II) femoral neck fractures is thought to influence rates of reoperation. However, an exact method for its measurement has not yet been presented. We designed a new measurement for posterior tilt on preoperative lateral......, and rate of reoperation within the first year. In a subgroup of 50 randomly selected patients, reliability tests for measurement of posterior tilt were performed. RESULTS: Intra- and interclass coefficients for the new measurement were > or = 0.94. 23% (26/113) of patients were reoperated and increased...... score, time from admission to operation, surgeon's expertise, postoperative reduction, and implant positioning, a preoperative posterior tilt of > or = 20 degrees was the only significant predictor of reoperation (p measurement for posterior tilt appears to be reliable...

  20. Mathematical Model and Analysis of the Water-Lubricated Hydrostatic Journal Bearings considering the Translational and Tilting Motions

    Directory of Open Access Journals (Sweden)

    Hui-Hui Feng

    2014-01-01

    Full Text Available The water-lubricated bearings have been paid attention for their advantages to reduce the power loss and temperature rise and increase load capacity at high speed. To fully study the complete dynamic coefficients of two water-lubricated, hydrostatic journal bearings used to support a rigid rotor, a four-degree-of-freedom model considering the translational and tilting motion is presented. The effects of tilting ratio, rotary speed, and eccentricity ratio on the static and dynamic performances of the bearings are investigated. The bulk turbulent Reynolds equation is adopted. The finite difference method and a linear perturbation method are used to calculate the zeroth- and first-order pressure fields to obtain the static and dynamic coefficients. The results suggest that when the tilting ratio is smaller than 0.4 or the eccentricity ratio is smaller than 0.1, the static and dynamic characteristics are relatively insensitive to the tilting and eccentricity ratios; however, for larger tilting or eccentricity ratios, the tilting and eccentric effects should be fully considered. Meanwhile, the rotary speed significantly affects the performance of the hydrostatic, water-lubricated bearings.

  1. Simulation of short-term pressure regulation during the tilt test in a coupled 3D-0D closed-loop model of the circulation.

    Science.gov (United States)

    Lau, Kevin D; Figueroa, C Alberto

    2015-08-01

    Short-term fluctuations in arterial pressures arising from normal physiological function are buffered by a negative feedback system known as the arterial baroreflex. Initiated by altered biomechanical stretch in the vessel wall, the baroreflex coordinates a systemic response that alters heart rate, cardiac contractility and peripheral vessel vasoconstriction. In this work, a coupled 3D-0D formulation for the short-term pressure regulation of the systemic circulation is presented. Including the baroreflex feedback mechanisms, a patient-specific model of the large arteries is subjected to a simulated head up tilt test. Comparative simulations with and without baroreflex control highlight the critical role that the baroreflex has in regulating variations in pressures within the systemic circulation.

  2. Perception of slow pitch and roll body tilts in bilateral labyrinthine-defective subjects.

    Science.gov (United States)

    Bringoux, Lionel; Schmerber, Sébastien; Nougier, Vincent; Dumas, Georges; Barraud, Pierre Alain; Raphel, Christian

    2002-01-01

    The aim of the present study was to examine whether the perception of slow body tilts in total darkness was affected by a complete loss of vestibular function. Four blindfolded bilateral labyrinthine-defective subjects (LDs) and 12 normal subjects (Normals) were seated and immobilized with large straps against the back of a rotating L-shaped platform, and were passively displaced from the upright at 0.05 degrees x s(-1) in the pitch and roll dimensions. Subjects were asked to detect the slow change in their body orientation, by indicating as soon as possible the direction of tilt. After a brief period of practice observed for all LDs at the beginning of the session, results showed no significant difference between LDs and Normals in the mean detection threshold recorded for each direction of tilt. The mean perceptual threshold was 4.4 versus 5.1 degrees in the roll dimension, and 6.1 versus 6.1 degrees in the pitch dimension, for the LDs and Normals, respectively. These findings indicate that the accurate perception of body orientation in quasi-static conditions is mainly allowed by somatosensory information rather than by otolithic inputs.

  3. Tilted foils polarization at REX-ISOLDE

    CERN Document Server

    Tornqvist, H; Yordanov, D T; Imai, N; Heinz, A; Nilsson, T; Sotty, C; Hass, M; Georgiev, G; Johansson, H; Dhal, A; Stuchbery, A; Wenander, F; Hirayama, Y; Kusoglu, A; Balabanski, D

    2013-01-01

    The tilted-foils nuclear-spin polarization method has been evaluated using the REX-ISOLDE linear accelerator at the ISOLDE facility, CERN. A beam of Li-8 delivered with an energy of 300 keV/u traversed through one Mylar foil to degrade the beam energy to 200 keV/u and consequently through 10 thin diamond-like carbon foils to polarize the nuclear spin. The attained nuclear spin polarization of 3.6 +/- 0.3% was measured with a beta-NMR setup. (C) 2013 Elsevier B.V. All rights reserved.

  4. A simple and low cost tilt examiner system development for a precise landslide early warning system

    Science.gov (United States)

    Salam, R. A.; Habil, H.; Yuliza, E.; Munir, M. M.; Irsyam, M.; Khairurrijal

    2016-05-01

    Historical data for every disaster provide the information about every single physical phenomenon that can be observed to estimate and monitor the happening of the next disaster event. Some physical parameter that often be investigated are ground movement and changing inclination of the land. Those phenomena are the key points on predicting the occurrence of disaster especially landslide and volcano eruption. One of the method that can be used to prevent the loss of life caused by the disasters is by observing the movement and the change of the slope of inclination at the prone areas using tilt sensor. The increase of possibility of disaster occurrence is reflected on the increase of tilt sensor usage. Therefore, a simple system for testing the performance of a tilt sensor is required. A simple and low cost tilt calibrator has been made by using a stepper motor that is controlled by AVR ATMega8 in which its data and control parameter would be displayed in a 16×2 LCD. The system calibrator was developed to test the readings of the slope from the MMA8451Q accelerometer sensor by moving forward from 0° to 90° and then backward from 90° to 0°. The hysteresis curves of this sensor for each axis have been investigated. Small hysteresis values have been found at the results of MMA8451Q sensor measurement which mean that the sensor has a high degree of stability.

  5. In situ, real-time measurement of wing tilt during lateral epitaxial overgrowth of GaN

    Energy Technology Data Exchange (ETDEWEB)

    Fini, P. [Materials Department, University of California, Santa Barbara, Santa Barbara, California 93106 (United States); Munkholm, A. [Chemistry Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Thompson, Carol [Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Stephenson, G. B. [Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Eastman, J. A. [Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Murty, M. V. Ramana [Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Auciello, O. [Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Zhao, L. [Materials Department, University of California, Santa Barbara, Santa Barbara, California 93106 (United States); DenBaars, S. P. [Materials Department, University of California, Santa Barbara, Santa Barbara, California 93106 (United States); Speck, J. S. [Materials Department, University of California, Santa Barbara, Santa Barbara, California 93106 (United States)

    2000-06-26

    By performing in situ, real-time x-ray diffraction measurements in the metalorganic chemical-vapor deposition environment, we have directly observed the emergence and evolution of wing tilt that occurs during the lateral overgrowth of GaN from stripes patterned in a SiO{sub 2} mask. This was done by repeatedly performing line scans through the 101(bar sign)3 peak in the direction perpendicular to the [101(bar sign)0]{sub GaN} stripe direction. The wing tilt developed as soon as the wings started forming, and increased slightly thereafter to reach a value of {approx}1.19 degree sign after 3600 s of growth. Upon cooldown to room temperature, the tilt increased to {approx}1.36 degree sign , indicating that thermally induced stresses during cooldown have only a small effect on wing tilt. However, changes in mask density, composition, and stress state during early lateral overgrowth must be considered as possible origins of wing tilt. (c) 2000 American Institute of Physics.

  6. An efficient eikonal solver for tilted transversely isotropic and tilted orthorhombic media

    KAUST Repository

    Waheed, Umair bin

    2014-01-01

    Computing first-arrival traveltimes in the presence of anisotropy is important for high-end near surface modeling, microseismic source localization, and fractured reservoir characterization. Anisotropy deviating from elliptical anisotropy introduces higher-order nonlinearity into the eikonal equation, which makes solving the equation a challenging task. We address this challenge by iteratively solving a sequence of simpler tilted elliptically anisotropic eikonal equations. At each iteration, the source function is updated to capture the effects due to the higher order nonlinear terms in the anisotropy. We use Aitken extrapolation to speed up the convergence rate of the iterative algorithm. The result is an efficient algorithm for firstarrival traveltime computations in tilted anisotropic media. We demonstrate the proposed method for the tilted transversely isotropic media and the tilted orthorhombic media. Numerical tests show that the proposed method is feasible and produces results that are comparable to wavefield extrapolation, even for strongly anisotropic and complex structures. Therefore, for the cases where one or two-point ray tracing fails, our method may be a potential substitute for computing traveltimes.

  7. Effect of pelvic tilt on lumbar spine geometry.

    Science.gov (United States)

    Delisle, A; Gagnon, M; Sicard, C

    1997-12-01

    The purpose of this study was to use a noninvasive method to determine the effect of pelvic tilt on the lumbar spine geometry in the sagittal plane. Five healthy male subjects were instructed in performing active forward and backward pelvic tilt manoeuvres in the standing position. The lumbar spine geometry (severity of lordosis, pelvis and lumbar vertebrae orientations) was estimated with a lumbar spine geometric model. The voluntary backward pelvic tilt succeeded in reducing the depth of the lumbar spine curvature, but the forward tilt did not change it. Both pelvic tilt manoeuvres influenced the absolute orientations of the lower lumbar vertebrae and the relative orientations of some lumbar vertebrae. Interestingly, the L5/S1 joint showed was little affected by the pelvic tilt manoeuvres.

  8. The deceleration parameter in `tilted' Friedmann universes

    CERN Document Server

    Tsagas, Christos G

    2015-01-01

    Large-scale peculiar motions are believed to reflect the local inhomogeneity and anisotropy of the universe, triggered by the ongoing process of structure formation. As a result, realistic observers do not follow the smooth Hubble flow, but have a peculiar, `tilt', velocity relative to it. Our Local Group of galaxies, in particular, moves with respect to the universal expansion at a speed of roughly 600~km/sec. Relative motion effects are known to interfere with the observations and their interpretation. The strong dipolar anisotropy seen in the the Cosmic Microwave Background, for example, is not a sign of real universal anisotropy, but a mere artifact of our peculiar motion relative to the Hubble flow. With these in mind, we look into the implications of large-scale bulk motions for the kinematics of their associated observers, by adopting a `tilted' Friedmann model. Our aim is to examine whether the deceleration parameter measured in the rest-frame of the bulk flow can differ from that of the actual univer...

  9. INVESTIGATIONS ON OPERATION OF ROTARY TILTING FURNACES

    Directory of Open Access Journals (Sweden)

    S. L. Rovin

    2016-01-01

    Full Text Available Rotary tilting furnace (RTF is a new type of fuel furnaces, that provide the most efficient heating and recycling of polydisperse materials. The paper describes results of the investigations on thermal processes in the RTF, movement of materials and non-isothermal gas flow during kiln rotary process. The investigations have been carried out while using physical and computer simulations and under actual operating conditions applying the pilot plant. Results of the research have served as a basis for development of recommendations on the RTF calculations and designing and they have been also used for constructional design of a rotary tilting furnace for heating and melting of cast iron chips, reduction smelting of steel mill scale, melting of aluminum scrap, melting of lead from battery scrap. These furnaces have a high thermal efficiency (~50 %, technological flexibility, high productivity and profitability. Proven technical solutions for recycling of ferrous and non-ferrous metals develop the use of RTF in the foundry and metallurgical industry as the main technological unit for creation of cost-effective small-tonnage recycling of metal waste generated at the plants. The research results open prospects for organization of its own production for high-quality charging material in Belarus in lieu of imported primary metal. The proposed technology makes it possible to solve environmental challenge pertaining to liquidation of multi-tonnage heaps of metal-containing wastes.

  10. Rotating Shaft Tilt Angle Measurement Using an Inclinometer

    OpenAIRE

    2015-01-01

    This paper describes a novel measurement method to accurately measure the rotating shaft tilt angle of rotating machine for alignment or compensation using a dual-axis inclinometer. A model of the rotating shaft tilt angle measurement is established using a dual-axis inclinometer based on the designed mechanical structure, and the calculation equation between the rotating shaft tilt angle and the inclinometer axes outputs is derived under the condition that the inclinometer axes are perpendic...

  11. Mapping of moveout in tilted transversely isotropic media

    KAUST Repository

    Stovas, A.

    2013-09-09

    The computation of traveltimes in a transverse isotropic medium with a tilted symmetry axis tilted transversely isotropic is very important both for modelling and inversion. We develop a simple analytical procedure to map the traveltime function from a transverse isotropic medium with a vertical symmetry axis (vertical transversely isotropic) to a tilted transversely isotropic medium by applying point-by-point mapping of the traveltime function. This approach can be used for kinematic modelling and inversion in layered tilted transversely isotropic media. © 2013 European Association of Geoscientists & Engineers.

  12. Study on the vehicle license plate tilt correction

    Institute of Scientific and Technical Information of China (English)

    Li Guihui; Li Yuanjin; Li Lanyou

    2006-01-01

    The shortage of current different approaches of the vehicle license plate(VLP) tilt correction is analyzed in the paper and a new rotary correction method put forward based on the former ways of the VLP tilt correction in the horizontal direction and the vertical direction Owing to the VLP tilt taking place in the vertical direction, the array of the image's pixels of the same column is broken, and even different rows come into being superposition.The VLP tilt taking place in the horizontal direction, by which the array of the image's pixels of the same row broken, and so much as different columns come into being superposition.

  13. Introducer curving technique to reduce tilting of transfemoral Gunther Tulip IVC filter: in vitro study.

    Science.gov (United States)

    Xiao, Liang; Wang, Man; Huang, De-Sheng; Shen, Jing; Tong, Jia-Jie

    2012-09-01

    Severe tilting of Günther Tulip filter (GTF) may be associated with difficulty in retrieval. To determine if an introducer curving technique of GTF can decrease the tilting degree of GTF in a caval model. The model was constructed by placing Dacron grafts in bifurcated glass tubes. The study included three groups: Right Straight Group (G(1)), Left Straight Group (G(2)), and Left Curved Group (G(3)). In G(3), a 10-20° angle was curved on the metal introducer before insertion to decrease the angle between inferior vena cava axes and metal introducer (A(CM)). Before GTF was released, the distance between the caval right wall and the apical hook (D(CH1)), and A(CM) were measured. The tilt angle of GTF (A(CF)) was also measured. In G(1), GTF apex tended to center compared to G(2) (59% vs. 36%, P < 0.01). In G(3), GTF apex tended to center compared to G(2) (71% vs. 36%, P < 0.01). The differences of A(CF) between G(1) and G(2) (2.66 ± 1.80 vs. 4.13 ± 2.07, P < 0.01) and between G(2) and G(3) (4.13 ± 2.07 vs. 2.39 ± 1.79, P < 0.01) were statistically significant. There were significant positive correlations between A(CM) and A(CF), whereas significant negative correlations were detected between D(CH1) and A(CF) in each group. The oblique course of GTF delivery system relative to the axis of the cava causes filter tilt, and thus, curving the introducer prior to its introduction helps to reduce the filter tilt. We recommend a clinical study to determine whether the introducer curving technique improves filter centering and its retrievability.

  14. Clogging Tranistion in a Tilted Silo

    Science.gov (United States)

    Thomas, Charles; Durian, Douglas

    2010-03-01

    Granular media flow freely from large horizontal holes at the bottom of a container. However, if the hole is too small, or tilted too far from horizontal, a clog will eventually form at the exit and halt the flow. The number of beads which exit before a clog forms follows an exponential distribution. The average of this distribution increases with increasing hole size and with decreasing angle from horizontal, diverging above a critical hole size. We measure these hole sizes at different angles. The critical hole size as a function of angle constitutes the system's phase transition on a clogging phase diagram. In comparison, the hole sizes where the Beverloo equation predicts the flux to vanish are less than half these critical hole sizes.

  15. Design, Fabrication and Testing of Fixture for Implementation of a New Approach to Incorporate Tool tilting in Friction Stir Welding

    Directory of Open Access Journals (Sweden)

    Awang Mokhtar

    2014-07-01

    Full Text Available Friction Stir Welding (FSW is solid-state process for joining materials by using frictional heat generated due to rotating tool along the weld line. Since its invention about two decades ago, wide spread use of FSW is still restricted due to very expensive purpose built FSW machines available in the market. As an alternative, a milling machine can be used to carry out the FSW depending on the capabilities of the machine. In cases where milling machines have a fixed head, limitation of zero degree tool tilt angle results in substantial defects (e.g. tunnel defect in weldments. The objective of this study is to design and fabricate an adjustable-angle fixture to incorporate tool tilting in a CNC milling machine with fixed spindle head. The testing of the fabricated fixture is then carried out by running the FSW experiments at different tilt angles.

  16. Perverse equivalences, BB-tilting, mutations and applications

    CERN Document Server

    Ladkani, Sefi

    2010-01-01

    We relate the notions of BB-tilting and perverse derived equivalence at a vertex. Based on these notions, we define mutations of algebras, leading to derived equivalent ones. We present applications to endomorphism algebras of cluster-tilting objects in 2-Calabi-Yau categories and to algebras of global dimension at most 2.

  17. Contravariantly finite subcategories in a tilting torsion class

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The contravariant finiteness of the subcategory consisting of modules with T-dimension not more than 1 in the torsion class induced by a tilting module T is proved under the condition that the projective dimension of the injective hull of the tilting module is not more than one.

  18. Vesicle shape, molecular tilt, and the suppression of necks.

    Science.gov (United States)

    Jiang, Hongyuan; Huber, Greg; Pelcovits, Robert A; Powers, Thomas R

    2007-09-01

    Can the presence of molecular-tilt order significantly affect the shapes of lipid bilayer membranes, particularly membrane shapes with narrow necks? Motivated by the propensity for tilt order and the common occurrence of narrow necks in the intermediate stages of biological processes such as endocytosis and vesicle trafficking, we examine how tilt order inhibits the formation of necks in the equilibrium shapes of vesicles. For vesicles with a spherical topology, point defects in the molecular order with a total strength of +2 are required. We study axisymmetric shapes and suppose that there is a unit-strength defect at each pole of the vesicle. The model is further simplified by the assumption of tilt isotropy: invariance of the energy with respect to rotations of the molecules about the local membrane normal. This isotropy condition leads to a minimal coupling of tilt order and curvature, giving a high energetic cost to regions with Gaussian curvature and tilt order. Minimizing the elastic free energy with constraints of fixed area and fixed enclosed volume determines the allowed shapes. Using numerical calculations, we find several branches of solutions and identify them with the branches previously known for fluid membranes. We find that tilt order changes the relative energy of the branches, suppressing thin necks by making them costly, leading to elongated prolate vesicles as a generic family of tilt-ordered membrane shapes.

  19. Angular momentum projection of tilted axis rotating states

    Energy Technology Data Exchange (ETDEWEB)

    Oi, M.; Onishi, N.; Tajima, N. [Tokyo Univ. (Japan); Horibata, T.

    1998-03-01

    We applied an exact angular momentum projection to three dimensional cranked HFB (3d-CHFB) states. Tilted axis rotating states (TAR) and principal axis rotating states (PAR) are compared. It is shown that TAR is more adequate than PAR for description of the back bending phenomena driven by tilted rotation or wobbling motion. (author)

  20. Orthostatic symptoms does not always manifest during tilt-table test in pediatric postural orthostatic tachycardia syndrome patients

    Directory of Open Access Journals (Sweden)

    Tae-Eon Huh

    2013-01-01

    Full Text Available &lt;b&gt;Purpose:&lt;/b&gt; Chronic day-to-day symptoms of orthostatic intolerance are the most notable features of postural orthostatic tachycardia syndrome (POTS. However, we have encountered patients with such symptoms and excessive tachycardia but with no symptoms during the tilt-table test (TTT. We aimed to investigate whether POTS patients with chronic orthostatic intolerance always present orthostatic symptoms during the TTT and analyze the factors underlying symptom manifestation during this test. &lt;b&gt;Methods:&lt;/b&gt; We retrospectively examined patients who presented with POTS at the Gyeongsang Na tional University Hospital between 2008 and 2011. Diagnosis of POTS was based on chronic day-to-day orthostatic intolerance symptoms as well as excessive tachycardia during the TTT. The patients were divided two groups depending on the presentation of orthostatic symptoms during the TTT. Clinical data and the results of the TTT were compared between these groups. &lt;b&gt;Results:&lt;/b&gt; In 22 patients, 7 patients (31.8% did not present orthostatic symptoms during the test. Diastolic blood pressure (BP was significantly lower in the symptom-positive group. The head-up tilt resulted in a significant increase in diastolic BP in the symptom-negative group (&lt;i&gt;P&lt;/i&gt; =0.04, while systolic BP had a tendency to decrease in the symptom-positive group (&lt;i&gt;P&lt;/i&gt; =0.06. &lt;b&gt;Conclusion:&lt;/b&gt; Significant patients with POTS did not present orthostatic symptoms during the TTT despite having chronic daily symptoms. This finding may be important for establishing definitive diagnostic criteria for pediatric POTS. Development of symptoms during TTT might be related to low diastolic BP and abnormal compensatory responses to orthostasis.

  1. Investigation of Peak Pressure Index Parameters for People with Spinal Cord Injury Using Wheelchair Tilt-in-Space and Recline: Methodology and Preliminary Report

    Directory of Open Access Journals (Sweden)

    Chi-Wen Lung

    2014-01-01

    Full Text Available The purpose of this study was to determine the effect of the sensel window’s location and size when calculating the peak pressure index (PPI of pressure mapping with varying degrees of wheelchair tilt-in-space (tilt and recline in people with spinal cord injury (SCI. Thirteen power wheelchair users were recruited into this study. Six combinations of wheelchair tilt (15°, 25°, and 35° and recline (10° and 30° were used by the participants in random order. Displacements of peak pressure and center of pressure were extracted from the left side of the mapping system. Normalized PPI was computed for three sensel window dimensions (3 sensels × 3 sensels, 5 × 5, and 7 × 7. At least 3.33 cm of Euclidean displacement of peak pressures was observed in the tilt and recline. For every tilt angle, peak pressure displacement was not significantly different between 10° and 30° recline, while center of pressure displacement was significantly different (P<.05. For each recline angle, peak pressure displacement was not significantly different between pairs of 15°, 25°, and 35° tilt, while center of pressure displacement was significantly different between 15° versus 35° and 25° versus 35°. Our study showed that peak pressure displacement occurs in response to wheelchair tilt and recline, suggesting that the selected sensel window locations used to calculate PPI should be adjusted during changes in wheelchair configuration.

  2. What is the optimal duration of tilt testing for the assessment of patients with suspected postural tachycardia syndrome?

    LENUS (Irish Health Repository)

    Carew, Sheila

    2012-01-31

    AIMS: The aim of this study is to define the optimal duration of tilt testing for the assessment of patients with suspected postural tachycardia syndrome (POTS). METHODS AND RESULTS: This was a case-control study. Cases were identified retrospectively from a database of patients referred with orthostatic intolerance (OI). All met the diagnostic criteria for POTS. Controls were enrolled prospectively. All subjects underwent tilting to 70 degrees for 40 min if tolerated. Continuous monitoring was provided by a Finometer. Analysis of responses to tilting was performed on 28 cases and 28 controls. The mean age in the case group was 23.6 and in the control group was 26.2. The majority was female in both groups (cases = 4F:3M, controls = 2F:1M). All cases met the criteria for POTS within 7 min of orthostasis. No controls demonstrated a sustained tachycardia. The prevalence of vasovagal syncope (VVS) was 36% in cases vs. 7% in controls (P = 0.02) and 25% in the remaining patients (n = 233) on the OI database (P = 0.259). CONCLUSION: A 10 min tilt will diagnose POTS in the majority of patients. It will not, however, be sufficient to identify the overlap that exists between POTS and VVS. The optimal duration of tilt testing in patients suspected of POTS is 40 min.

  3. The tilting rate of the Milky Way's disc

    Science.gov (United States)

    Earp, Samuel W. F.; Debattista, Victor P.; Macciò, Andrea V.; Cole, David R.

    2017-08-01

    We present tilting rates for galaxies comparable to the Milky Way (MW) in a Λ cold dark matter cosmological hydrodynamical simulation, and compare these with the predicted tilting rate detection limit of the Gaia satellite 0.28° Gyr-1. We first identify galaxies with mass comparable to the MW (9 × 1011 ≤ M200 ≤ 1.2 × 1012 M⊙) and consider the tilting rates between z = 0.3 and 0. This sample yields a tilting rate of 7.6° ± 4.5° Gyr-1. We constrain our sample further to exclude any galaxies that have high stellar accretion during the same time. We still find significant tilting, with an average rate of 6.3° Gyr-1. Both subsamples tilt with rates significantly above Gaia's predicted detection limit. We show that our sample of galaxies covers a wide range of environments, including some similar to the MW's. We find galaxies in denser regions tilt with higher rates then galaxies in less dense regions. We also find correlations between the angular misalignment of the hot gas corona and the tilting rate. Gaia is likely to be able to directly measure tilting in the MW. Such a detection will provide an important constraint on the environment of the MW, including the rate of gas cooling on to the disc, the shape and orientation of its dark matter halo, and the mass of the Large Magellanic Cloud. Conversely, failure to detect tilting may suggest the MW is in a very quiet configuration.

  4. Gastrointestinal Physiology During Head Down Tilt Bedrest in Human Subjects

    Science.gov (United States)

    Vaksman, Z.; Guthienz, J.; Putcha, L.

    2008-01-01

    Introduction: Gastrointestinal (GI) motility plays a key role in the physiology and function of the GI tract. It directly affects absorption of medications and nutrients taken by mouth, in addition to indirectly altering GI physiology by way of changes in the microfloral composition and biochemistry of the GI tract. Astronauts have reported nausea, loss of appetite and constipation during space flight all of which indicate a reduction in GI motility and function similar to the one seen in chronic bed rest patients. The purpose of this study is to determine GI motility and bacterial proliferation during -6 degree head down tilt bed rest (HTD). Methods: Healthy male and female subjects between the ages of 25-40 participated in a 60 day HTD study protocol. GI transit time (GITT) was determined using lactulose breath hydrogen test and bacterial overgrowth was measured using glucose breath hydrogen test. H. Pylori colonization was determined using C13-urea breath test (UBIT#). All three tests were conducted on 9 days before HDT, and repeated on HDT days 2, 28, 58, and again on day 7 after HDT. Results: GITT increased during HTD compared to the respective ambulatory control values; GITT was significantly lower on day 7 after HTD. A concomitant increase in bacterial colonization was also noticed during HDT starting after approximately 28 days of HDT. However, H. Pylori proliferation was not recorded during HDT as indicated by UBIT#. Conclusion: GITT significantly decreased during HDT with a concomitant increase in the proliferation of GI bacterial flora but not H. pylori.

  5. Dissipation strength of the tilting degree of freedom in fusion-fission reactions

    Directory of Open Access Journals (Sweden)

    Nadtochy P. N.

    2016-01-01

    Full Text Available The four-dimensional Langevin model was applied to calculate a wide set of experimental observables for compound nuclei, formed in heavy-ion fusion-fission reactions. A modified one-body mechanism for nuclear dissipation with a reduction coefficient ks of the contribution from a “wall” formula was used for shapes parameters. Different possibilities of deformation-dependent dissipation coefficient for the K coordinate (γK were investigated. Presented results demonstrate that the influence of the ks and γK parameters on the calculated quantities can be selectively probed. It was found that it is possible to describe experimental data with the deformation-dependent γK coefficient. One of the possibility is to use large values of γK ≃ 0.2 (MeV zs−1/2 for compact shapes featuring no neck and small values of γK ≃ 0.0077 (MeV zs−1/2 for elongated shapes.

  6. Exercise Thermoregulation in Men after One and 24-hours of 6 Degree Head-Down Tilt

    Science.gov (United States)

    Ertl, A. C.; Dearborn, A. S.; Weldhofer, A. R.; Bernauer, E. M.; Greenleaf, J. E.

    1998-01-01

    Exercise thermoregulation exercise is dependent on heat loss by increased skin blood flow (convective and conductive heat loss) and through enhanced sweating (evaporative heat loss). Reduction of plasma volume (PV), increased plasma osmolality, physical deconditioning, and duration of exposure to simulated and actual microgravity reduces the ability to thermoregulate during exercise.

  7. Head-Up; An interdisciplinary, participatory and co-design process informing the development of a novel head and neck support for people living with progressive neck muscle weakness.

    Science.gov (United States)

    Reed, Heath; Langley, Joe; Stanton, Andy; Heron, Nicola; Clarke, Zoe; Judge, Simon; McCarthy, Avril; Squire, Gill; Quinn, Ann; Wells, Oliver; Tindale, Wendy; Baxter, Susan; Shaw, Pamela J; McDermott, Christopher J

    2014-01-01

    This paper presents the Head-Up project, that aims to provide innovative head support to help improve posture, relieve pain and aid communication for people living with progressive neck muscle weakness. The initial focus is motor neurone disease. The case study illustrates collaborative, interdisciplinary research and new product development underpinned by participatory design. The study was initiated by a 2-day stakeholder workshop followed by early proof-of-concept modelling and patient need evidence building. The work subsequently led to a successful NIHR i4i application funding a 24-month iterative design process, patenting, CE marking and clinical evaluation. The evaluation has informed amendments to the proposed design refered to here as the Sheffield Support Snood (SSS). The outcome positively demonstrates use and performance improvements over current neck orthoses and the process of multidisciplinary and user engagement has created a sense of ownership by MND participants, who have since acted as advocates for the product.

  8. IOL tilt and decentration estimation from 3 dimensional reconstruction of OCT image.

    Directory of Open Access Journals (Sweden)

    Xiaogang Wang

    Full Text Available PURPOSE: To evaluate intraocular lens (IOL tilt and decentration by anterior segment optical coherence tomography (AS-OCT using 3-dimensional (3D reconstruction method. DESIGN: Prospective observational case series. PARTICIPANTS: Thirty-nine patients (39 eyes were included. METHODS: The IOL positions of all eyes were examined by AS-OCT. Images were obtained in 4 axes (0-180 degrees, 45-225 degrees, 90-270 degrees, and 135-315 degrees using the quadrant-scan model. The cross-sectional images were analyzed with MATLAB software. MAIN OUTCOME MEASURES: The angle (θ between the reference pupillary plane and the IOL plane, the distances between the center points of the pupil circle and the IOL on the x-axis (dx and y-axis (dy and the spatial distance (ds were calculated after 3D-reconstruction. RESULTS: The mean angle (θ between the pupillary plane and the IOL plane was 2.94±0.99 degrees. The mean IOL decentration of dx and dy was 0.32±0.26 mm and 0.40±0.27 mm, respectively. The ds of the IOL decentration was 0.56±0.31 mm. There was no significant correlation between the ocular residual astigmatism (ORA and the tilted angle or the decentration distance. There was a significant correlation between the ORA and total astigmatism (r = 0.742, P<0.001. There was no significant correlation between the postoperative best corrected visual acuity (BCVA and the ORA (r = 0.156; P = 0.344, total astigmatism (r = 0.012; P = 0.942, tilted angle (θ; r = 0.172; P = 0.295 or decentration distance (dx: r = 0.191, P = 0.244; dy: r = 0.253, P = 0.121; ds: r = 0.298, P = 0.065. CONCLUSIONS: AS-OCT can be used as an alternative for the analysis of IOL tilt and decentration using 3D-reconstruction.

  9. Tilt sensor and servo control system for gravitational wave detection

    CERN Document Server

    Cheng, Y; Ju, L; Blair, D G

    2002-01-01

    This paper describes the design of a novel double-flexure two-axis tilt sensor with a tilt readout based on an optical walk-off sensor. The performance of the device has been investigated theoretically and experimentally. The walk-off sensor has demonstrated a sensitivity of 10 sup - sup 1 sup 1 rad Hz sup - sup 1 sup / sup 2 at 1 Hz. The tilt sensor has measured seismic noise approx 10 sup - sup 9 -10 sup - sup 1 sup 0 rad Hz sup - sup 1 sup / sup 2 for frequency in the 2-10 Hz range.

  10. Single and Multiple Phase Shifts Tilted Fiber Bragg Gratings

    Directory of Open Access Journals (Sweden)

    Christophe Caucheteur

    2009-01-01

    Full Text Available The spectral behavior of single and multiple phase shifts tilted fiber Bragg gratings has been experimentally investigated. To this aim, a simple and cost-effective postprocessing technique based on local thermal treatment was used to create arbitrary phase shifts along the tilted grating structure. In particular, UV written tilted fiber Bragg gratings were treated by the electric arc discharge to erase the refractive index modulation in well-defined regions. We demonstrate that these defects give rise to interference pattern for all modes, and thus defect states can be achieved within all the attenuation bands, enabling a simple wavelength independent spectral tailoring of this class of devices.

  11. STS-44 DSP / IUS spacecraft tilted to predeployment position in OV-104's PLB

    Science.gov (United States)

    1991-01-01

    STS-44 Defense Support Program (DSP) / Inertial Upper Stage (IUS) spacecraft, with forward airborne support equipment (ASE) payload retention latch actuator released (foreground), is raised to a 29 degree predeployment position by the ASE aft frame tilt actuator (AFTA) table in the payload bay (PLB) of Atlantis, Orbiter Vehicle (OV) 104. Underneath the DSP / IUS combination, the umbilical boom is connected to the IUS. DSP components include Infrared (IR) sensor (top), AR I, SHF Antenna, EHF Antenna, Link 2 High-Gain Antenna, star sensor, and stowed solar paddles (box-like structure around the base). The Earth's limb and the blackness of space create the backdrop for this deployment scene.

  12. Male reproductive system in conditions of bed-rest in a head-down tilt.

    Science.gov (United States)

    Nichiporuk, I A; Evdokimov, V V; Erasova, V I; Smirnov, O A; Goncharova, A G; Vassilieva GYu; Vorobiev, D V

    1998-07-01

    Study of reproductive function in simulating experiments is important as for expansion of our theoretical knowledge in the field of gravitational physiology and space biology and for the decision of applied problems in space and clinical medicine. Long-term bed rest in a head-down tilt--6 degrees (BRHDT)--antiorthostatic hypokinesia is a wide spread method for ground-based simulation of space flight's conditions (mainly of hemodynamical effects of microgravity and restriction of locomotor activity). The aim of the present research was to study a reproductive function in males during 60-120 day BRHDT.

  13. [Evaluation of synthetic antidiuretic hormone as a corrective substance following head-down tilt].

    Science.gov (United States)

    Noskov, V B; Larina, I M; Nichiporuk, I A; Pastushkova, L Kh; Vasil'eva, G Iu

    2010-01-01

    Effects of synthesized desmopressin, analog of antidiuretic hormone, and water-salt supplement on the renal function and orthostatic stability were studied in 6 normal male subjects after 12-hr. head-down tilt (12 degrees). The combination of water-salt homeostasis normalizing methods was effective in retaining excessive liquid and salts. Moreover, tolerance of the standard 20-min. passive standing test improved significantly. Hence, it was demonstrated that intake of synthetic vasopressin analog combined with WSS counteracted hypohydration of organism due to HDT and improved orthostatic tolerance.

  14. [Desmopressin effect on water-salt homeostasis and orthostatic tolerance during head-down tilting].

    Science.gov (United States)

    Larina, I M; Noskov, V B; Nichiporuk, I A; Pastushkova, L Kh; Vasil'eva, G Iu

    2009-01-01

    Effects of desmopressin, a synthetic analog of antidiuretic hormone (ADH), on water-salt metabolism and orthostatic tolerance were evaluated in human subjects during 24-hr HDT (-15 degrees). Consumption of the preparation was found to dampen losses in total body and extracellular liquids and to slow down diuresis as well as establishment of a positive water balance as compared with control series without ADH. In addition, tolerance of the standard standing test improved noticeably. To conclude, desmopressin precluded hypohydration of the tilted subjects and, consequently, prevented loss of orthostatic tolerance.

  15. A tilting approach to ranking influence

    KAUST Repository

    Genton, Marc G.

    2014-12-01

    We suggest a new approach, which is applicable for general statistics computed from random samples of univariate or vector-valued or functional data, to assessing the influence that individual data have on the value of a statistic, and to ranking the data in terms of that influence. Our method is based on, first, perturbing the value of the statistic by ‘tilting’, or reweighting, each data value, where the total amount of tilt is constrained to be the least possible, subject to achieving a given small perturbation of the statistic, and, then, taking the ranking of the influence of data values to be that which corresponds to ranking the changes in data weights. It is shown, both theoretically and numerically, that this ranking does not depend on the size of the perturbation, provided that the perturbation is sufficiently small. That simple result leads directly to an elegant geometric interpretation of the ranks; they are the ranks of the lengths of projections of the weights onto a ‘line’ determined by the first empirical principal component function in a generalized measure of covariance. To illustrate the generality of the method we introduce and explore it in the case of functional data, where (for example) it leads to generalized boxplots. The method has the advantage of providing an interpretable ranking that depends on the statistic under consideration. For example, the ranking of data, in terms of their influence on the value of a statistic, is different for a measure of location and for a measure of scale. This is as it should be; a ranking of data in terms of their influence should depend on the manner in which the data are used. Additionally, the ranking recognizes, rather than ignores, sign, and in particular can identify left- and right-hand ‘tails’ of the distribution of a random function or vector.

  16. The effects of lateral head tilt on ocular astigmatic axis

    Directory of Open Access Journals (Sweden)

    Hamid Fesharaki

    2014-01-01

    Conclusion: Any minimal angle of head tilt may cause erroneous measurement of astigmatic axis and should be avoided during refraction. One cannot rely on the compensatory function of ocular counter-torsion during the refraction.

  17. Reflection loss of laser mode from tilted end mirror

    Energy Technology Data Exchange (ETDEWEB)

    Marcuse, D.

    1989-02-01

    The authors consider the reflection of the lowest order guided TE mode of a slab waveguide from a tilted end mirror. This problem is applicable to injection lasers if the slab is regarded as an effective refractive index approximation of the channel or ridge waveguide of the laser structure. For a mode width of 3 /mu/m, 5% mirror tilt results in reflection losses in excess of 25 dB for modes of 6/mu/m width, 5/sup 0/ mirror tilt causes reflection losses in excess of 45 dB. For small tilt angles the results of this calculation agree with those based on a Gaussian approximation of the guided mode. For larger angles, and hence higher reflection losses, the results depart significantly from the Gaussian approximation.

  18. Tilt of Emerging Bipolar Magnetic Regions on the Sun

    Science.gov (United States)

    Kosovichev, A. G.; Stenflo, J. O.

    2008-12-01

    Magnetic fields emerging from the Sun's interior carry information about the physical processes of magnetic field generation and transport in the convection zone. A statistical analysis of variations of the tilt angle of bipolar magnetic regions during the emergence, observed from SOHO MDI, shows that the systematic tilt with respect to the equator (Joy's law) is established by the middle of the emergence period. This suggests that the tilt is most likely generated below the surface. However, the data do not show evidence of a dependence of the tilt angle on the amount of flux or a relaxation of the bipolar orientation toward the east-west direction, in contrast to the predictions of the rising magnetic flux rope theories.

  19. Effect of beam quality on tilt measurement using cyclic interferometer

    Science.gov (United States)

    Pretheesh Kumar, V. C.; Ganesan, A. R.; Joenathan, C.; Somasundaram, U.

    2016-08-01

    Accurate measurement of angles is extremely important in various metrological applications. Interferometry has always been an excellent technique for accurate measurements. Several methods have been proposed for accurate tilt measurement using interferometric techniques. Almost all of them use the Michelson configuration which is extremely sensitive to environmental vibrations and turbulences. We know that a cyclic interferometer is extremely stable. Even though it is not sensitive to displacement changes, it is twice sensitive to tilt compared to that of a Michelson interferometer. We have enhanced the sensitivity to measure tilt using multiple reflections in a cyclic interferometer. Since the input beam is collimated, we have studied the effect of aberration of the input beam on the accuracy of tilt measurement. Experimental results on this study are presented in this paper.

  20. Dynamic UCLA for single tilted implant in an aesthetic region

    National Research Council Canada - National Science Library

    Goiato, Marcelo Coelho; Sônego, Mariana Vilela; da Silva, Emily Vivianne Freitas; de Carvalho Dekon, Stefan Fiuza; de Medeiros, Rodrigo Antonio; Carvalho, Karina Helga Turcio de; Dos Santos, Daniela Micheline

    2015-01-01

    ...) for a single tilted implant in the anterior maxillary area. A 57-year-old male patient attended the dentistry college clinic complaining of a vertical fracture of a residual root of the dental element 22...

  1. Which way is down? Positional distortion in the tilt illusion.

    Science.gov (United States)

    Tomassini, Alessandro; Solomon, Joshua Adam; Morgan, Michael John

    2014-01-01

    Contextual information can have a huge impact on our sensory experience. The tilt illusion is a classic example of contextual influence exerted by an oriented surround on a target's perceived orientation. Traditionally, the tilt illusion has been described as the outcome of inhibition between cortical neurons with adjacent receptive fields and a similar preference for orientation. An alternative explanation is that tilted contexts could produce a re-calibration of the subjective frame of reference. Although the distinction is subtle, only the latter model makes clear predictions for unoriented stimuli. In the present study, we tested one such prediction by asking four naive subjects to estimate three positions (4, 6, and 8 o'clock) on an imaginary clock face within a tilted surround. To indicate their estimates, they used either an unoriented dot or a line segment, with one endpoint at fixation in the middle of the surround. The surround's tilt was randomly chosen from a set of orientations (± 75°, ± 65°, ± 55°, ± 45°, ± 35°, ± 25°, ± 15°, ± 5° with respect to vertical) across trials. Our results showed systematic biases consistent with the tilt illusion in both conditions. Biases were largest when observers attempted to estimate the 4 and 8 o'clock positions, but there was no significant difference between data gathered with the dot and data gathered with the line segment. A control experiment confirmed that biases were better accounted for by a local coordinate shift than to torsional eye movements induced by the tilted context. This finding supports the idea that tilted contexts distort perceived positions as well as perceived orientations and cannot be readily explained by lateral interactions between orientation selective cells in V1.

  2. Comparing dynamic surface tilt with velocity using an LDV

    Science.gov (United States)

    Bruce, Robert A.

    2004-06-01

    If a laser Doppler vibrometer (LDV) probe beam is normally incident on a resonating metal strip with a mirror-finish, the retro-reflected beam has corresponding dynamic deflections. These lateral beam offsets are proportional to the dynamic surface tilt and can be measured along with the LDV velocity using a separating beam-splitter and a two-dimensional position sensitive detector (PSD). On a thin unbound strip resonating with 'pure mode' deformation, these derivative motions, velocity and tilt, are completely complementary. On a thin unbound plate resonating with 'hybrid mode' deformation, velocity and now two orthogonal tilts are nearly complementary. Maximal tilt has zero velocity, and maximum deformation or velocity has zero tilt. Intermediate values range in complementary fashion except near 'cross-nodes' zones. Here both motion types drop to zero at these cross-node locations. Both velocity and tilt signals are compared simultaneously using a special test fixture. This fixture consists of a stainless steel strip supported on its edges in the center, which can be excited by small speakers at the ends. Two comparison/calibration approaches are demonstrated with a pure 3-0 mode. Significant modal details are also demonstrated by analyzing multiple modes from pulsed excitation, and mapping a 3-1 mode-shape using the combined sensing approaches.

  3. A New Method for Correcting Vehicle License Plate Tilt

    Institute of Scientific and Technical Information of China (English)

    Mei-Sen Pan; Qi Xiong; Jun-Biao Yan

    2009-01-01

    In the course of vehicle license plate (VLP) automatic recognition, tilt correction is a very crucial process. According to Karhunen-Loeve (K-L) transformation, the coordinates of characters in the image are arranged into a two-dimensional covariance matrix, on the basis of which the centered process is carried out. Then, the eigenvector and the rotation angle α are computed in turn. The whole image is rotated by -α. Thus, image horizontal tilt correction is performed. In the vertical tilt correction process, three correction methods, which are K-L transformation method, the line fitting method based on K-means clustering (LFMBKC), and the line fitting based on least squares (LFMBLS), are put forward to compute the vertical tilt angle θ. After shear transformation (ST) is imposed on the rotated image, the final correction image is obtained. The experimental results verify that this proposed method can be easily implemented, and can quickly and accurately get the tilt angle. It provides a new effective way for the VLP image tilt correction as well.

  4. Tilted hexagonal post arrays: DNA electrophoresis in anisotropic media.

    Science.gov (United States)

    Chen, Zhen; Dorfman, Kevin D

    2014-02-01

    Using Brownian dynamics simulations, we show that DNA electrophoresis in a hexagonal array of micron-sized posts changes qualitatively when the applied electric field vector is not coincident with the lattice vectors of the array. DNA electrophoresis in such "tilted" post arrays is superior to the standard "un-tilted" approach; while the time required to achieve a resolution of unity in a tilted post array is similar to an un-tilted array at a low-electric field strengths, this time (i) decreases exponentially with electric field strength in a tilted array and (ii) increases exponentially with electric field strength in an un-tilted array. Although the DNA dynamics in a post array are complicated, the electrophoretic mobility results indicate that the "free path," i.e. the average distance of ballistic trajectories of point-sized particles launched from random positions in the unit cell until they intersect the next post, is a useful proxy for the detailed DNA trajectories. The analysis of the free path reveals a fundamental connection between anisotropy of the medium and DNA transport therein that goes beyond simply improving the separation device.

  5. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... intensity stationary biking, and moderate-intensity weightlifting. D Put the athlete back into unrestricted play. E Reintegrate ... intensity stationary biking, and moderate-intensity weightlifting. D Put the athlete back into unrestricted play. E Reintegrate ...

  6. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Free Online Training (Developed in partnership with the National Federation of State High School Associations) GET MORE INFORMATION ON CONCUSSION and TRAUMATIC BRAIN INJURY IN THE UNITED STATES Statistics Causes Outcomes Prevention COMMUNICATING EFFECTIVELY ABOUT ...

  7. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Environmental Health Workplace Safety & Health Global Health Life Stages & Populations State, Tribal, Local & Territorial Data & Statistics Vital ... CDC Jobs Funding LEGAL Policies Privacy FOIA No Fear Act OIG 1600 Clifton Road Atlanta , GA 30329- ...

  8. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... 2 Which of the following is true? A Most concussions occur without loss of consciousness. B Athletes ... QUIZ QUESTION 3 Concussions affect people differently. While most athletes with a concussion recover quickly and fully, ...

  9. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Fact Sheet Download a Fact Sheet on Overall Sports Safety: Protect the Ones You Love For parents ... Exit Disclaimer] Concussion Educational Materials for all NCAA Sports Download Materials [Exit Disclaimer] Watch a Video or ...

  10. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... contact sports-specific drills. B Start light aerobic exercise, but only to increase an athlete’s heart rate–meaning 5-10 minutes on an exercise bike, walking, or light jogging. No weight lifting, ...

  11. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... answering questions slowly. B The athlete follows the rules for safety and the rules of the sport, practices good sportsmanship, and uses ... good sportsmanship at all times, and obey the rules of safety. B By working with parents, athletes, ...

  12. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Matthew Alan Gfeller Sport-Related TBI Research Center, University of North Carolina at Chapel Hill May Clinic ... of Health, Physical Education & Recreation Sports Legacy Institute University of Pittsburgh Medical Center, Sports Medicine Concussion Program ...

  13. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... a Fact Sheet on Overall Sports Safety: Protect the Ones You Love For parents Order Free Copies ... Providers Materials for School Professionals Learn More about the Brain and How it Works Order Free Copies ...

  14. Projection/Reflection Heads-up Display

    Data.gov (United States)

    National Aeronautics and Space Administration — To address the NASA need for an extravehicular activity (EVA) information display device, Physical Optics Corporation (POC) proposes to advance development of a new...

  15. Heads up ... for Bas-Relief

    Science.gov (United States)

    King, Steve

    2010-01-01

    Art teachers need to experiment with new techniques and materials in order to keep their art instruction fresh, and to avoid becoming droning bores with tired, repetitive projects. Usually it only takes a brief flip through any art-supply catalog for an art teacher to happen onto some previously unknown material that will inspire them and--when…

  16. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... gov . CDC Home Diseases & Conditions Healthy Living Travelers’ Health Emergency Preparedness Injury, Violence & Safety Environmental Health Workplace Safety & Health Global Health Life Stages & Populations ...

  17. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Testing FAQs on Baseline Testing Fact Sheet Download a Fact Sheet on Overall Sports Safety: Protect the ... all NCAA Sports Download Materials [Exit Disclaimer] Watch a Video or PSA on Concussion NFL PSA on ...

  18. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Skip directly to site content Start of Search Controls Search Form Controls Search The CDC Cancel Submit Search The CDC ... V W X Y Z # Start of Search Controls Search Form Controls Search The CDC Cancel Submit ...

  19. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Feeling sluggish, hazy, foggy, or groggy Concentration or memory problems Confusion Does not "feel right" LESSON 2 ... sluggish, hazy, foggy, or groggy 17 Concentration or memory problems 18 Confusion 19 Just not “feeling right” ...

  20. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... chances for long-term problems. B You can’t see a concussion like you can a broken ... even briefly) Shows behavior or personality changes Can't recall events prior to hit or fall Can' ...

  1. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... have symptoms that last for days, or even weeks. A more serious concussion can last for months ... is slowly increased over a period of days, weeks, or months depending on the athlete’s response to ...

  2. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Search The CDC Cancel Submit Search The CDC Injury Prevention & Control: Concussion Note: Javascript is disabled or is ... Disease Control and Prevention , Â National Center for Injury Prevention and Control , Â Division of Unintentional Injury Prevention ...

  3. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Health Association American School Health Association American Sports Education Program Brain Injury Association of America Brain Trauma ... School Principals National Council for Youth Sports National Education Association National Education Association Health Information Network National ...

  4. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... 2017 Page last updated: April 24, 2017 Content source: Centers for Disease Control and Prevention , Â National ... INFO U.S. Department of Health & Human Services HHS/Open USA.gov Top

  5. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... You will need a score of 80% or higher to pass. Please review the lessons and then ... Health Association American School Health Association American Sports Education Program Brain Injury Association of America Brain Trauma ...

  6. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... to Know,” [Exit Disclaimer] Free Online Training (Developed in partnership with the National Federation of State High ... MORE INFORMATION ON CONCUSSION and TRAUMATIC BRAIN INJURY IN THE UNITED STATES Statistics Causes Outcomes Prevention COMMUNICATING ...

  7. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... ON Concussion And Traumatic Brian Injury In The USA Communicating Effectively Sports-Specific Information LESSON 1 QUIZ ... Participating Orginizations Amateur Athletic Union Amateur Softball Association/USA Softball American Academy of Neurology American Academy of ...

  8. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Materials for School Professionals Learn More about the Brain and How it Works Order Free Copies of ... Associations) GET MORE INFORMATION ON CONCUSSION and TRAUMATIC BRAIN INJURY IN THE UNITED STATES Statistics Causes Outcomes ...

  9. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Learn More about the Brain and How it Works Order Free Copies of CDC's “Heads Up” Educational ... American Academy of Physical Medicine and Rehabilitation American College of Sports Medicine American Medical Society for Sports ...

  10. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Learn More about the Brain and How it Works Order Free Copies of CDC's “Heads Up” Educational ... Up! Prevent Concussions Prevent Head Injuries Sports Safety Students Play Safe Youth Sports Safety PROMOTIONAL MATERIALS "Heads ...

  11. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... and obey the rules of safety. B By working with parents, athletes, school and club administrators to spread awareness about concussions ... Sports Materials for Health Care Providers Materials for School ... about the Brain and How it Works Order Free Copies of CDC's “Heads Up” Educational ...

  12. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Learn More about the Brain and How it Works Order Free Copies of CDC's “Heads Up” Educational ... Chapel Hill May Clinic MSU, Institute for the Study of Youth Sports National Academy of Neuropsychology National ...

  13. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... course's overview page for more information, including technical requirements: https://www.cdc.gov/headsup/youthsports/training/index. ... 232-6348 Email CDC-INFO U.S. Department of Health & Human Services HHS/Open USA.gov Top

  14. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Materials on Concussion in Sports Materials for Health Care Providers Materials for School Professionals Learn More about the ... Materials on Concussion in Sports Materials for Health Care Providers Materials for School Professionals Order Large Quantities of ...

  15. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... or dizziness Double or blurry vision Sensitivity to light Sensitivity to noise Feeling sluggish, hazy, foggy, or ... 13 Double or blurry vision 14 Sensitivity to light 15 Sensitivity to noise 16 Feeling sluggish, hazy, ...

  16. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... concussion are at increased risk for another concussion. C Young children and teens are more likely to ... how the brain works and a serious issue. C While rare, permanent brain damage and death are ...

  17. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... To Concussions Getting Back In The Game Concussion Prevention Resource Center Menu Button Return To Training Downloadable ... concussion than adults and they take longer to recover than adults. D All of the above. Submit ...

  18. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... of State High School Associations) Listen to a Radio PSA Coach and Team [Audio: 0:30 seconds] ... of State High School Associations) Listen to a Radio PSA Coach and Team [Audio: 0:30 seconds] ...

  19. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... slowly Loses consciousness (even briefly) Shows behavior or personality changes Can't recall events prior to hit ... consciousness (even briefly) 7 Shows mood, behavior, or personality changes 8 Can’t recall events prior to ...

  20. Heads Up: Concussion in Youth Sports

    Science.gov (United States)

    ... Hockey Football Ice Hockey Lacrosse Rugby Soccer Softball Volleyball Play Mute Back Next Participating Orginizations Amateur Athletic ... Soccer USA Baseball USA Football USA Rugby USA Volleyball YMCA of the USA Name Fancy Enter your ...

  1. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... D Put the athlete back into unrestricted play. E Reintegrate the athlete in practice sessions, even full ... D Put the athlete back into unrestricted play. E Reintegrate the athlete in practice sessions, even full ...

  2. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Statistics Vital Signs Feature Archive Tools & Resources Get Email Updates To receive email updates about this page, ... cdc.gov/headsup/youthsports/training/index.html . Get Email Updates To receive email updates about this page, ...

  3. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... The CDC Cancel Submit Search The CDC Injury Prevention & Control: Concussion Note: Javascript is disabled or is ... 2017 Content source: Centers for Disease Control and Prevention , Â National Center for Injury Prevention and Control , ...

  4. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Professionals Learn More about the Brain and How it Works Order Free Copies of CDC's “Heads Up” ... Enter your full name as you'd like it to appear on your completion certificate. Name: Submit

  5. Heads Up: Concussion in Youth Sports

    Science.gov (United States)

    ... Fact Sheet Download a Fact Sheet on Overall Sports Safety: Protect the Ones You Love For parents ... Exit Disclaimer] Concussion Educational Materials for all NCAA Sports Download Materials [Exit Disclaimer] Watch a Video or ...

  6. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Submit What's this? Submit Button Concussion in ... to the course's overview page for more information, including technical requirements: https://www.cdc.gov/headsup/youthsports/training/index. ...

  7. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... GET MORE INFORMATION ON CONCUSSION and TRAUMATIC BRAIN INJURY IN THE UNITED STATES Statistics Causes Outcomes Prevention ... School Health Association American Sports Education Program Brain Injury Association of America Brain Trauma Foundation Center for ...

  8. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... Can't recall events prior to hit or fall Can't recall events after hit or fall Close SYMPTOMS REPORTED by ATHLETES Headache or "pressure" ... Can’t recall events prior to hit or fall 9 Can’t recall events after hit or ...

  9. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... or longer. A True B False Submit POST TEST QUESTION 1 A concussion is a: A type ... loud sound heard from far away. Submit POST TEST QUESTION 2 When can concussions occur? A Only ...

  10. Forward dynamics simulation of human body under tilting perturbations

    Science.gov (United States)

    Naderi, D.; Pasha Zanoosi, A. A.; Sadeghi-Mehr, M.

    2012-02-01

    Human body uses different strategies to maintain its stability and these strategies vary from fixed-foot strategies to strategies which foot is moved in order to increase the support base. Tilting movement of foot is one type of the perturbations usually is exposed to human body. In the presence of such perturbations human body must employ appropriate reactions to prevent threats like falling. But it is not clear that how human body maintains its stability by central nervous system (CNS). At present study it is tried that by presenting a musculoskeletal model of human lower extremity with four links, three degrees of freedom (DOF) and eight skeletal muscles, the level of muscle activations causes the maintenance of stability, be investigated. Using forward dynamics solution, leads to a more general problem, rather than inverse dynamics. Hence, forward dynamics solution by forward optimization has been used for solving this highly nonlinear problem. To this end, first the system's equations of motion has been derived using lagrangian dynamics. Eight Hill-type muscles as actuators of the system were modeled. Because determination of muscle forces considering their number is an undetermined problem, optimization of an appropriate goal function should be practiced. For optimization problem, the characteristics of genetic algorithms as a method based on direct search, and the direct collocation method, has been profited. Also by considering requirements of problem, some constraints such as conservation of model stability are entered into optimization procedure. Finally to investigate validation of model, the results from optimization and experimental data are compared and good agreements are obtained.

  11. Introducer curving technique for the prevention of tilting of transfemoral Günther Tulip inferior vena cava filter.

    Science.gov (United States)

    Xiao, Liang; Huang, De-sheng; Shen, Jing; Tong, Jia-jie

    2012-01-01

    To determine whether the introducer curving technique is useful in decreasing the degree of tilting of transfemoral Tulip filters. The study sample group consisted of 108 patients with deep vein thrombosis who were enrolled and planned to undergo thrombolysis, and who accepted transfemoral Tulip filter insertion procedure. The patients were randomly divided into Group C and Group T. The introducer curving technique was Adopted in Group T. The post-implantation filter tilting angle (ACF) was measured in an anteroposterior projection. The retrieval hook adhering to the vascular wall was measured via tangential cavogram during retrieval. The overall average ACF was 5.8 ± 4.14 degrees. In Group C, the average ACF was 7.1 ± 4.52 degrees. In Group T, the average ACF was 4.4 ± 3.20 degrees. The groups displayed a statistically significant difference (t = 3.573, p = 0.001) in ACF. Additionally, the difference of ACF between the left and right approaches turned out to be statistically significant (7.1 ± 4.59 vs. 5.1 ± 3.82, t = 2.301, p = 0.023). The proportion of severe tilt (ACF ≥ 10°) in Group T was significantly lower than that in Group C (9.3% vs. 24.1%, χ(2) = 4.267, p = 0.039). Between the groups, the difference in the rate of the retrieval hook adhering to the vascular wall was also statistically significant (2.9% vs. 24.2%, χ(2) = 5.030, p = 0.025). The introducer curving technique appears to minimize the incidence and extent of transfemoral Tulip filter tilting.

  12. The Effect of Spironolactone on the Cardiocirculatory Responses to Upright Tilt at Sea Level and at Simulated High Altitude,

    Science.gov (United States)

    2014-09-26

    cardiocirculatory parameters measured in the supine or upright’"osition at SL or during HA. It was concluded that S did not induce a significant diuresis or... diuresis or significantly alter vascular responsiveness to negatively effect the normal cardiocirculatory responses to upright tilt at sea level or...By blocking this exchange, increased amounts of water and sodium are excreted while the loss of potassium is prevented. The degree of diuresis caused

  13. Magnetic configurations of the tilted current sheets in magnetotail

    Directory of Open Access Journals (Sweden)

    C. Shen

    2008-11-01

    Full Text Available In this research, the geometrical structures of tilted current sheet and tail flapping waves have been analysed based on multiple spacecraft measurements and some features of the tilted current sheets have been made clear for the first time. The geometrical features of the tilted current sheet revealed in this investigation are as follows: (1 The magnetic field lines (MFLs in the tilted current sheet are generally plane curves and the osculating planes in which the MFLs lie are about vertical to the equatorial plane, while the normal of the tilted current sheet leans severely to the dawn or dusk side. (2 The tilted current sheet may become very thin, the half thickness of its neutral sheet is generally much less than the minimum radius of the curvature of the MFLs. (3 In the neutral sheet, the field-aligned current density becomes very large and has a maximum value at the center of the current sheet. (4 In some cases, the current density is a bifurcated one, and the two humps of the current density often superpose two peaks in the gradient of magnetic strength, indicating that the magnetic gradient drift current is possibly responsible for the formation of the two humps of the current density in some tilted current sheets. Tilted current sheets often appear along with tail current sheet flapping waves. It is found that, in the tail flapping current sheets, the minimum curvature radius of the MFLs in the current sheet is rather large with values around 1 RE, while the neutral sheet may be very thin, with its half thickness being several tenths of RE. During the flapping waves, the current sheet is tilted substantially, and the maximum tilt angle is generally larger than 45°. The phase velocities of these flapping waves are several tens km/s, while their periods and wavelengths are several tens of minutes, and several earth radii, respectively. These tail flapping events generally last several hours and occur

  14. The vestibulo-ocular reflex of the squirrel monkey during eccentric rotation and roll tilt

    Science.gov (United States)

    Merfeld, D. M.; Young, L. R.

    1995-01-01

    The vestibulo-ocular reflexes (VOR) are determined not only by angular acceleration, but also by the presence of gravity and linear acceleration. This phenomenon was studied by measuring three-dimensional nystagmic eye movements, with implanted search coils, in six male squirrel monkeys during eccentric rotation. Monkeys were rotated in the dark at a constant velocity of 200 degrees/s (centrally or 79 cm off axis) with the axis of rotation always aligned with gravity and the spinal axis of the upright monkeys. The monkey's orientation (facing-motion or back-to-motion) had a dramatic influence on the VOR. These experiments show that: (a) the axis of eye rotation always shifted toward alignment with gravito-inertial force; (b) the peak value of horizontal slow phase eye velocity was greater with the monkey facing-motion than with back-to-motion; and (c) the time constant of horizontal eye movement decay was smaller with the monkey facing-motion than with back-to-motion. All of these findings were statistically significant and consistent across monkeys. In another set of tests, the same monkeys were rapidly tilted about their naso-occipital (roll) axis. Tilted orientations of 45 degrees and 90 degrees were maintained for 1 min. Other than a compensatory angular VOR during the angular rotation, no consistent eye velocity response was observed during or following the tilt for any of the six monkeys. The absence of any eye movement response following tilt weighs against the possibility that translational linear VOR responses are due to simple high-pass filtering of the otolith signals. The VOR response during eccentric rotation was divided into the more familiar angular VOR and linear VOR components. The angular component is known to depend upon semicircular canal dynamics and central influences. The linear component of the response decays rapidly with a mean duration of only 6.6 s, while the axis of eye rotation rapidly aligns (< 10 s) with gravito-inertial force. These

  15. Effect of Vestibular Impairment on Cerebral Blood Flow Response to Dynamic Roll Tilt

    Science.gov (United States)

    Serrador, J. M.; Black, F. O.; Schlgel, Todd T.; Lipsitz, L. A.; Wood, S. J.

    2008-01-01

    Change to upright posture results in reductions in cerebral perfusion pressure due to hydrostatic pressure changes related to gravity. Since vestibular organs, specifically the otoliths, provide information on position relative to gravity, vestibular inputs may assist in adaptation to the upright posture. The goal of this study was to examine the effect of direct vestibular stimulation on cerebral blood flow (CBF). To examine the role of otolith inputs we screened 165 subjects for vestibular function and classified subjects as either normal or impaired based on ocular torsion. Ocular torsion, an indication of otolith function, was assessed during sinusoidal roll tilt of 20 degrees at 0.01 Hz (100 sec per cycle). Subjects with torsion one SD below the mean were classified as impaired while subjects one SD above the mean were considered normal. During one session subjects were placed in a chair that was sinusoidally rotated 25 degrees in the roll plane at five frequencies: 0.25 & 0.125 Hz for 80 sec, 0.0625 Hz for 160 sec and 0.03125 Hz and 0.015625 Hz for 320 sec. During testing, CBF (transcranial Doppler), blood pressure (Finapres), and end tidal CO2 (Puritan Bennet) were measured continuously. Ocular torsion was assessed from infrared images of the eyes. All rotations were done in the dark with subjects fixated on a red LED directly at the center of rotation. In the normal group, dynamic tilt resulted in significant changes in both blood pressure and cerebral blood flow velocity that was related to the frequency of stimulus. In contrast the impaired group did not show similar patterns. As expected normal subjects demonstrated significant ocular torsion that was related to stimulus frequency while impaired subjects had minimal changes. These data suggest that vestibular inputs have direct effects on cerebral blood flow regulation during dynamic tilt. Supported by NASA.

  16. Rules and mechanisms governing octahedral tilts in perovskites under pressure

    Science.gov (United States)

    Xiang, H. J.; Guennou, Mael; Íñiguez, Jorge; Kreisel, Jens; Bellaiche, L.

    2017-08-01

    The rotation of octahedra (octahedral tilting) is common in A B O3 perovskites and relevant to many physical phenomena, ranging from electronic and magnetic properties, metal-insulator transitions to improper ferroelectricity. Hydrostatic pressure is an efficient way to tune and control octahedral tiltings. However, the pressure behavior of such tiltings can dramatically differ from one material to another, with the origins of such differences remaining controversial. In this paper, we discover several new mechanisms and formulate a set of simple rules that allow us to understand how pressure affects oxygen octahedral tiltings via the use and analysis of first-principles results for a variety of compounds. Besides the known A -O interactions, we reveal that the interactions between specific B ions and oxygen ions contribute to the tilting instability. We explain the previously reported trend that the derivative of the oxygen octahedral tilting with respect to pressure (dR /dP ) usually decreases with both the tolerance factor and the ionization state of the A ion by illustrating the key role of A -O interactions and their change under pressure. Furthermore, three new mechanisms/rules are discovered, namely that (i) the octahedral rotations in A B O3 perovskites with empty low-lying d states on the B site are greatly enhanced by pressure, in order to lower the electronic kinetic energy; (ii) dR /dP is enhanced when the system possesses weak tilt instabilities, and (iii) for the most common phase exhibited by perovskites—the orthorhombic Pbnm state—the in-phase and antiphase octahedral rotations are not automatically both suppressed or both enhanced by the application of pressure because of a trilinear coupling between these two rotation types and an antipolar mode involving the A ions. We further predict that the polarization associated with the so-called hybrid improper ferroelectricity could be manipulated by hydrostatic pressure by indirectly controlling the

  17. Recording Tilt with Broadband Seismic Sensors at Erupting Volcanoes

    Science.gov (United States)

    Young, B. E.; Lees, J. M.; Lyons, J. J.

    2011-12-01

    The horizontal components of broadband seismometers are known to be susceptible to gravitational acceleration due to slow tilting, and this has been successfully exploited to assess ground deformation at many volcanoes, including Anatahan (Mariana Islands), Meakan-dake (Japan), Santiaguito (Guatemala) and Stromboli (Italy). Tilt can be estimated from seismic velocity by differentiating, scaling to remove gravity, and applying an instrument correction. The fundamental assumption in estimating tilt from broadband data is that the signal recorded is the result of tilt and not translation, thus analysis of tilt require filtering below corner frequencies of seismic instruments, where the response to tilt should be flat. However, processing techniques for deriving tilt are not uniform among researchers. Filter type and passband allowance for the processing of data sets differs from case to case, and the dominant periods of tilt signals may vary from tens to hundreds of seconds. For instance, data from Santiaguito was filtered in the 600-30s passband, while at Anatahan filters spanned 13 hours to 8 minutes. In our study, we investigate tilt from seismic data sets at Karymsky (Kamchatka, Russia), Fuego (Guatemala), Yasur (Vanuatu), and Tungurahua (Ecuador) to understand implementation and limitations of this tool. We examine the importance of filter-type distortion related to filtering on the seismic signal. For example, a comparison of time domain versus frequency domain implementation is explored using a variety of lowpass and bandpass filters. We also investigate the advantages and drawbacks of causal versus acausal filters. In a few cases tiltmeters have been co-located with broadband seismic sensors for direct comparison. Signals at Mt. St. Helens, Stromboli, Sakurajima, and Semeru show a correlation of tilt and seismic records, although records at Karymsky volcano suggest that no tilt is recorded on either instrument. We speculate that strong vent explosions exhibit

  18. Irregularities in Pump-Induced Tilt Above Shallow Aquifers

    Science.gov (United States)

    Kuempel, H. J.; Fabian, M.

    2003-12-01

    Near surface ground tilt induced by the extraction of fluids from subsurface reservoirs has repeatedly been used to constrain reservoir parameters. In general, pump-induced tilt is found to be proportional in strength to the pore pressure gradient created by the pumping, to be a function of poroelastic rock parameters, and to depend on the geometric configuration of the tilt sensor and the productive sections of a well. Assuming radial flow, the strike of the tilt signal should point toward the productive well. However, inversion of near surface tilt can be hampered through irregularities in the pump-induced signal and suffer from insufficient knowledge of the influence of heterogeneities in the subsoil, either within or above the reservoir. We can learn more about the impact of such heterogeneities and reduce ambiguities by analyzing case studies. New observational data from 3 test sites in Germany confirm that a variety of causes can produce irregularities in pump-induced surface deformation, namely: (1) The strike of a tilt signal can considerably deviate from the direction toward the active well. A reason could be that the steepest effective pore pressure gradient builds up in another than radial direction (thereby generating anisotropic fluid flow). Accordingly, tilt hodographs for a complete pump cycle may be elliptic rather than follow a line. (2) The normal rule of how the signal strength depends on the horizontal and the vertical distance may be violated. Structural heterogeneities in the subsurface are the most likely cause for this behaviour. (3) Recovery of the induced tilt signal following the cessation of pumping can be incomplete. This could indicate a non-reversible compaction possibly due to overexploitation of a reservoir. (4) A transient sign reversal of ground tilt may occur during the build-up phase of the signal. This feature could be an analogue to the so-called Noordbergum effect occasionally seen in the response of well levels at locations

  19. Modulated electron bunch with amplitude front tilt in an undulator

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2015-12-15

    In a previous paper we discussed the physics of a microbunched electron beam kicked by the dipole field of a corrector magnet by describing the kinematics of coherent undulator radiation after the kick. We demonstrated that the effect of aberration of light supplies the basis for understanding phenomena like the deflection of coherent undulator radiation by a dipole magnet. We illustrated this fact by examining the operation of an XFEL under the steady state assumption, that is a harmonic time dependence. We argued that in this particular case the microbunch front tilt has no objective meaning; in other words, there is no experiment that can discriminate whether an electron beam is endowed with a microbunch front tilt of not. In this paper we extend our considerations to time-dependent phenomena related with a finite electron bunch duration, or SASE mode of operation. We focus our attention on the spatiotemporal distortions of an X-ray pulse. Spatiotemporal coupling arises naturally in coherent undulator radiation behind the kick, because the deflection process involves the introduction of a tilt of the bunch profile. This tilt of the bunch profile leads to radiation pulse front tilt, which is equivalent to angular dispersion of the output radiation. We remark that our exact results can potentially be useful to developers of new generation XFEL codes for cross-checking their results.

  20. The peculiar velocity field: constraining the tilt of the Universe

    CERN Document Server

    Ma, Yin-Zhe; Feldman, Hume A

    2010-01-01

    A large bulk flow, which is in tension with the Lambda Cold Dark Matter cosmological model, has been observed \\cite{Watkins08,Feldman09}. In this letter, we provide a physical explanation for this very large bulk flow, based on the assumption that the cosmic microwave background (CMB) rest frame does not coincide with the matter rest frame, resulting in a "tilted Universe". We propose a model that takes into account the relative velocity of CMB frame with respect to to the matter rest frame (hereafter tilted velocity), and use Type Ia Supernovae (SN), ENEAR, SFI++, SMAC, and COMPOSITE galaxy catalogues to constrain this tilted velocity. We find that: (1) the magnitude of the tilted velocity $u$ is around 400 km/s, and its direction is close to what is found by \\cite{Watkins08}; for SN, SMAC and COMPOSITE catalogues, $u=0$ is excluded at the two to three sigma level; (2) the constraints on the magnitude of the tilted velocity can result in the constraints on the duration of inflation, due to the fact that infl...

  1. Conservative GRMHD simulations of moderately thin, tilted accretion disks

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Danilo Morales [Instituto de Astronomia, Geofísica e Ciências Atmosféricas, Universidade de São Paulo, São Paulo, SP 05508-090 (Brazil); Fragile, P. Chris [Department of Physics and Astronomy, College of Charleston, Charleston, SC 29424 (United States); Zhuravlev, Viacheslav V. [Sternberg Astronomical Institute, Moscow M. V. Lomonosov State University, Universitetskij pr. 13, 119992 Moscow (Russian Federation); Ivanov, Pavel B., E-mail: danilo.morales@iag.usp.br [Astro Space Centre, P. N. Lebedev Physical Institute, 84/32 Profsoyuznaya Street, 117810 Moscow (Russian Federation)

    2014-12-01

    This paper presents our latest numerical simulations of accretion disks that are misaligned with respect to the rotation axis of a Kerr black hole. In this work, we use a new, fully conservative version of the Cosmos++ general relativistic magnetohydrodynamics (GRMHD) code, coupled with an ad hoc cooling function designed to control the thickness of the disk. Together these allow us to simulate the thinnest tilted accretion disks ever using a GRMHD code. In this way, we are able to probe the regime where the dimensionless stress and scale height of the disk become comparable. We present results for both prograde and retrograde cases. The simulated prograde tilted disk shows no sign of Bardeen-Petterson alignment even in the innermost parts of the disk. The simulated retrograde tilted disk, however, does show modest alignment. The implication of these results is that the parameter space associated with Bardeen-Petterson alignment for prograde disks may be rather small, only including very thin disks. Unlike our previous work, we find no evidence for standing shocks in our simulated tilted disks. We ascribe this to the black hole spin, tilt angle, and disk scale height all being small in these simulations. We also add to the growing body of literature pointing out that the turbulence driven by the magnetorotational instability in global simulations of accretion disks is not isotropic. Finally, we provide a comparison between our moderately thin, untilted reference simulation and other numerical simulations of thin disks in the literature.

  2. Rotating Shaft Tilt Angle Measurement Using an Inclinometer

    Directory of Open Access Journals (Sweden)

    Luo Jun

    2015-10-01

    Full Text Available This paper describes a novel measurement method to accurately measure the rotating shaft tilt angle of rotating machine for alignment or compensation using a dual-axis inclinometer. A model of the rotating shaft tilt angle measurement is established using a dual-axis inclinometer based on the designed mechanical structure, and the calculation equation between the rotating shaft tilt angle and the inclinometer axes outputs is derived under the condition that the inclinometer axes are perpendicular to the rotating shaft. The reversal measurement method is applied to decrease the effect of inclinometer drifts caused by temperature, to eliminate inclinometer and rotating shaft mechanical error and inclinometer systematic error to attain high measurement accuracy. The uncertainty estimation shows that the accuracy of rotating shaft tilt angle measurement depends mainly on the inclinometer uncertainty and its uncertainty is almost the same as the inclinometer uncertainty in the simulation. The experimental results indicate that measurement time is 4 seconds; the range of rotating shaft tilt angle is 0.002° and its standard deviation is 0.0006° using NS-5/P2 inclinometer, whose precision and resolution are ±0.01° and 0.0005°, respectively.

  3. Rotating Shaft Tilt Angle Measurement Using an Inclinometer

    Science.gov (United States)

    Luo, Jun; Wang, Zhiqian; Shen, Chengwu; Wen, Zhuoman; Liu, Shaojin; Cai, Sheng; Li, Jianrong

    2015-10-01

    This paper describes a novel measurement method to accurately measure the rotating shaft tilt angle of rotating machine for alignment or compensation using a dual-axis inclinometer. A model of the rotating shaft tilt angle measurement is established using a dual-axis inclinometer based on the designed mechanical structure, and the calculation equation between the rotating shaft tilt angle and the inclinometer axes outputs is derived under the condition that the inclinometer axes are perpendicular to the rotating shaft. The reversal measurement method is applied to decrease the effect of inclinometer drifts caused by temperature, to eliminate inclinometer and rotating shaft mechanical error and inclinometer systematic error to attain high measurement accuracy. The uncertainty estimation shows that the accuracy of rotating shaft tilt angle measurement depends mainly on the inclinometer uncertainty and its uncertainty is almost the same as the inclinometer uncertainty in the simulation. The experimental results indicate that measurement time is 4 seconds; the range of rotating shaft tilt angle is 0.002° and its standard deviation is 0.0006° using NS-5/P2 inclinometer, whose precision and resolution are ±0.01° and 0.0005°, respectively.

  4. Tolerance on tilt error for coherent combining of fiber lasers

    Institute of Scientific and Technical Information of China (English)

    Pu Zhou; Zilun Chen; Xiaolin Wang; Xiao Li; Zejin Liu; Xiaojun Xu

    2009-01-01

    Limited by the precision of optical machining and assembling, the optical axes of lasers in an array cannot be strictly parallel to each other, which will result in the beam quality degradation of the combined beam. The tolerance on tilt error for coherent combining of fiber lasers is studied in detail. The complex amplitude distribution in the far field for the Gaussian beam with tilt angle is obtained by a novel coordinate transform method. Effect of tilt error on coherent combining is modelled analytically. Beam propagation factor is used to evaluate the effect of coherent combining. Numerical results show that for ring-distributed fiber laser array with central wavelength 位 and geometry size D, if the root-mean-square (RMS) value of the tilt error is smaller than 0.72位/D, the energy encircled in the diffraction-limited bucket can be ensured to be more than 50% of the value when there is no tilt error. The results are helpful to the designing and manufacturing of fiber array for coherent combining.

  5. Laser Guide Star Adaptive Optics without Tip-tilt

    CERN Document Server

    Davies, R; Lidman, C; Louarn, M Le; Kasper, M; Förster-Schreiber, N M; Roccatagliata, V; Ageorges, N; Amico, P; Dumas, C; Mannucci, F

    2008-01-01

    Adaptive optics (AO) systems allow a telescope to reach its diffraction limit at near infrared wavelengths. But to achieve this, a bright natural guide star (NGS) is needed for the wavefront sensing, severely limiting the fraction of the sky over which AO can be used. To some extent this can be overcome with a laser guide star (LGS). While the laser can be pointed anywhere in the sky, one still needs to have a natural star, albeit fainter, reasonably close to correct the image motion (tip-tilt) to which laser guide stars are insensitive. There are in fact many astronomical targets without suitable tip-tilt stars, but for which the enhanced resolution obtained with the Laser Guide Star Facility (LGSF) would still be very beneficial. This article explores what adaptive optics performance one might expect if one dispenses with the tip-tilt star, and in what situations this mode of observing might be needed.

  6. Quantum well electronic states in a tilted magnetic field

    Science.gov (United States)

    Trallero-Giner, C.; Padilha, J. X.; Lopez-Richard, V.; Marques, G. E.; Castelano, L. K.

    2017-08-01

    We report the energy spectrum and the eigenstates of conduction and uncoupled valence bands of a quantum well under the influence of a tilted magnetic field. In the framework of the envelope approximation, we implement two analytical approaches to obtain the nontrivial solutions of the tilted magnetic field: (a) the Bubnov-Galerkin spectral method and b) the perturbation theory. We discuss the validity of each method for a broad range of magnetic field intensity and orientation as well as quantum well thickness. By estimating the accuracy of the perturbation method, we provide explicit analytical solutions for quantum wells in a tilted magnetic field configuration that can be employed to study several quantitative phenomena.

  7. Flow tilt angles near forest edges - Part 1: Sonic anemometry

    DEFF Research Database (Denmark)

    Dellwik, Ebba; Mann, Jakob; Larsen, Klaus Steenberg

    2010-01-01

    -sets. These features of the investigated sonic anemometers make them unsuitable for measuring vertical velocities over highly turbulent forested terrain. By comparing the sonic anemometer results to that of a conically scanning Doppler lidar (Dellwik et al., 2010b), sonic anemometer accuracy for measuring mean flow...... distortion and vertical alignment, it was only possible to a limited extent to relate sonic anemometer flow tilt angles to upwind forest edges, but the results by the lidar indicated that an internal boundary layer affect flow tilt angles at 21m above the forest. This is in accordance with earlier studies......An analysis of flow tilt angles from a fetch-limited beech forest site with clearings is presented in the context of vertical advection of carbon dioxide. Flow angles and vertical velocities from two sonic anemometers by different manufacturers were analyzed. Instead of using rotations, where zero...

  8. Interacting tilt and kink instabilities in repelling current channels

    CERN Document Server

    Keppens, Rony; Xia, Chun

    2014-01-01

    We present a numerical study in resistive magnetohydrodynamics where the initial equilibrium configuration contains adjacent, oppositely directed, parallel current channels. Since oppositely directed current channels repel, the equilibrium is liable to an ideal magnetohydrodynamic tilt instability. This tilt evolution, previously studied in planar settings, involves two magnetic islands or fluxropes, which on Alfvenic timescales undergo a combined rotation and separation. This in turn leads to the creation of (near) singular current layers, posing severe challenges to numerical approaches. Using our open-source grid-adaptive MPI-AMRVAC software, we revisit the planar evolution case in compressible MHD, as well as its extension to 2.5D and full 3D scenarios. As long as the third dimension remains ignorable, pure tilt evolutions result which are hardly affected by out of plane magnetic field components. In all 2.5D runs, our simulations do show secondary tearing type disruptions throughout the near singular cur...

  9. STUDY ON DYNAMIC CURVING BEHAVIOR OF TILTING PASSENGER CARS

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    By using tilting carbodies, train can negotiate at a higher speed without reducing the passenger's ride quality.This is a good method to allow a significant increase in speed at existing track to improve the railway transportation capa-bility, and to enhance the competition ability of railways with other transportation systems. With the increase of the curvenegotiation speed, the wheel-rail lateral forces and wheel-rail wear of the tilting train will increase. The self-steering radialbogie is an effective way to solve the problem. The dynamic model of the tilting passenger car with self-steering bogies isestablished in detail, and the curving performance of the car is investigated.

  10. Coulomb interaction effect in tilted Weyl fermion in two dimensions

    Science.gov (United States)

    Isobe, Hiroki; Nagaosa, Naoto

    Weyl fermions with tilted linear dispersions characterized by several different velocities appear in some systems including the quasi-two-dimensional organic semiconductor α-(BEDT-TTF)2I3 and three-dimensional WTe2. The Coulomb interaction between electrons modifies the velocities in an essential way in the low energy limit, where the logarithmic corrections dominate. Taking into account the coupling to both the transverse and longitudinal electromagnetic fields, we derive the renormalization group equations for the velocities of the tilted Weyl fermions in two dimensions, and found that they increase as the energy decreases and eventually hit the velocity of light c to result in the Cherenkov radiation. Especially, the system restores the isotropic Weyl cone even when the bare Weyl cone is strongly tilted and the velocity of electrons becomes negative in certain directions.

  11. The semiology of tilt-induced psychogenic pseudosyncope.

    Science.gov (United States)

    Tannemaat, Martijn R; van Niekerk, Julius; Reijntjes, Robert H; Thijs, Roland D; Sutton, Richard; van Dijk, J Gert

    2013-08-20

    To provide a detailed semiology to aid the clinical recognition of psychogenic pseudosyncope (PPS), which concerns episodes of apparent transient loss of consciousness (TLOC) that mimic syncope. We analyzed all consecutive tilt-table tests from 2006 to 2012 showing proven PPS, i.e., apparent TLOC had occurred without EEG changes or a decrease in heart rate (HR) or blood pressure (BP). We analyzed baseline characteristics, video data, EEG, ECG, and continuous BP measurements on a 1-second time scale. Data were compared with those of 69 cases of tilt-induced vasovagal syncope (VVS). Of 800 tilt-table tests, 43 (5.4%) resulted in PPS. The majority (74%) were women. The median duration of apparent TLOC was longer in PPS (44 seconds) than in VVS (20 seconds, p semiology of PPS as a clinical entity is vital to ensure accurate diagnosis.

  12. Robust tilt and lock mechanism for hopping actuator

    Energy Technology Data Exchange (ETDEWEB)

    Salton, Jonathan R.; Buerger, Stephen; Dullea, Kevin J.; Marron, Lisa C.; Salisbury, Curt Michael; Spletzer, Barry Louis

    2017-02-07

    A tilt and lock apparatus that includes a tilt servomechanism, a spiral torsion spring, a lock wheel, and a lock hook is described herein. The spiral torsion spring is mechanically coupled to the tilt servomechanism and the lock wheel (which includes an opening). When a shaft is positioned through the opening, rotation of the lock wheel is in unison with rotation of the shaft. An external surface of the lock wheel includes one or more grooves. The lock hook includes a head that engages and disengages the grooves. The lock wheel is stationary when the head engages one of the grooves and is rotatable when the head disengages the grooves. The head and the grooves are geometrically aligned when engaged to prevent creation of a force that acts to disengage the head responsive to an applied force acting on the shaft.

  13. Full vector complex coupled mode theory for tilted fiber gratings.

    Science.gov (United States)

    Lu, Yu-Chun; Huang, Wei-Ping; Jian, Shui-Sheng

    2010-01-18

    A full vector complex coupled mode theory (CMT) for the analysis of tilted fiber gratings is presented. With the combination of the perfectly matched layer (PML) and the perfectly reflecting boundary (PRB), the continuous radiation modes are well represented by a set of discrete complex modes. Simulation of coupling to radiation modes is greatly simplified and may be treated in the same fashion as guided modes. Numerical results of the tilted fiber Bragg gratings (TFBGs) with outer-cladding index equal, lower and higher than that of the inner-cladding indicate that the complex coupled mode approach is highly effective in the simulation of couplings to cladding and radiation modes in tilted fiber gratings. The reflective TFBGs are investigated by the proposed approach in detail.

  14. Ground tilt monitoring at Phlegraean Fields (Italy: a methodological approach

    Directory of Open Access Journals (Sweden)

    C. Del Gaudio

    2003-06-01

    Full Text Available Among geodetic methods used for monitoring ground deformation in volcanic areas, tiltmetry represents the most rapid technique and therefore it is used by almost all the volcanological observatories in the world. The deformation of volcanic building is not only the result of endogenous causes (i.e. dykes injection or magma rising, but also non-tectonic environmental factors. Such troubles cannot be removed completely but they can be reduce. This article outlines the main source of errors affecting the signals recorded by Phlegraean tilt, network, such as the dependence of the tilt response on temperature and to the thermoelastic effect on ground deformation. The analytical procedure used to evaluate about such errors and their reduction is explained. An application to data acquired from the tilt network during two distinct phases of ground uplift and subsidence of the Phlegraean Fields is reported.

  15. Tilted dipole model for bias-dependent photoluminescence pattern

    Energy Technology Data Exchange (ETDEWEB)

    Fujieda, Ichiro, E-mail: fujieda@se.ritsumei.ac.jp; Suzuki, Daisuke; Masuda, Taishi [Department of Electrical and Electronic Engineering, Ritsumeikan University, Kusatsu 525-8577 (Japan)

    2014-12-14

    In a guest-host system containing elongated dyes and a nematic liquid crystal, both molecules are aligned to each other. An external bias tilts these molecules and the radiation pattern of the system is altered. A model is proposed to describe this bias-dependent photoluminescence patterns. It divides the liquid crystal/dye layer into sub-layers that contain electric dipoles with specific tilt angles. Each sub-layer emits linearly polarized light. Its radiation pattern is toroidal and is determined by the tilt angle. Its intensity is assumed to be proportional to the power of excitation light absorbed by the sub-layer. This is calculated by the Lambert-Beer's Law. The absorption coefficient is assumed to be proportional to the cross-section of the tilted dipole moment, in analogy to the ellipsoid of refractive index, to evaluate the cross-section for each polarized component of the excitation light. Contributions from all the sub-layers are added to give a final expression for the radiation pattern. Self-absorption is neglected. The model is simplified by reducing the number of sub-layers. Analytical expressions are derived for a simple case that consists of a single layer with tilted dipoles sandwiched by two layers with horizontally-aligned dipoles. All the parameters except for the tilt angle can be determined by measuring transmittance of the excitation light. The model roughly reproduces the bias-dependent photoluminescence patterns of a cell containing 0.5 wt. % coumarin 6. It breaks down at large emission angles. Measured spectral changes suggest that the discrepancy is due to self-absorption and re-emission.

  16. Interacting tilt and kink instabilities in repelling current channels

    Energy Technology Data Exchange (ETDEWEB)

    Keppens, R.; Porth, O.; Xia, C., E-mail: rony.keppens@wis.kuleuven.be [Centre for mathematical Plasma-Astrophysics, Department of Mathematics, KU Leuven, B-3001 Leuven (Belgium)

    2014-11-01

    We present a numerical study in resistive magnetohydrodynamics (MHD) where the initial equilibrium configuration contains adjacent, oppositely directed, parallel current channels. Since oppositely directed current channels repel, the equilibrium is liable to an ideal magnetohydrodynamic tilt instability. This tilt evolution, previously studied in planar settings, involves two magnetic islands or flux ropes, which on Alfvénic timescales undergo a combined rotation and separation. This in turn leads to the creation of (near) singular current layers, posing severe challenges to numerical approaches. Using our open-source grid-adaptive MPI-AMRVAC software, we revisit the planar evolution case in compressible MHD, as well as its extension to two-and-a-half-dimensional (2.5D) and full three-dimensional (3D) scenarios. As long as the third dimension can be ignored, pure tilt evolutions result that are hardly affected by out of plane magnetic field components. In all 2.5D runs, our simulations do show secondary tearing type disruptions throughout the near singular current sheets in the far nonlinear saturation regime. In full 3D runs, both current channels can be liable to additional ideal kink deformations. We discuss the effects of having both tilt and kink instabilities acting simultaneously in the violent, reconnection-dominated evolution. In 3D, both the tilt and the kink instabilities can be stabilized by tension forces. As a concrete space plasma application, we argue that interacting tilt-kink instabilities in repelling current channels provide a novel route to initiate solar coronal mass ejections, distinctly different from the currently favored pure kink or torus instability routes.

  17. Gating-by-Tilt of Mechanically Sensitive Membrane Channels

    Science.gov (United States)

    Turner, Matthew S.; Sens, Pierre

    2004-09-01

    We propose an alternative mechanism for the gating of biological membrane channels in response to membrane tension that involves a change in the slope of the membrane near the channel. Under biological membrane tensions we show that the energy difference between the closed (tilted) and open (untilted) states can far exceed kBT and is comparable to what is available under simple dilational gating. Recent experiments demonstrate that membrane leaflet asymmetries (spontaneous curvature) can strongly affect the gating of some channels. Such a phenomenon would be easier to explain under gating-by-tilt, given its novel intrinsic sensitivity to such asymmetry.

  18. The External Degree.

    Science.gov (United States)

    Houle, Cyril O.

    This book examines the external degree in relation to the extremes of attitudes, myths, and data. Emphasis is placed on the emergence of the American external degree, foreign external-degree programs, the purpose of the external degree, the current scene, institutional issues, and problems of general policy. (MJM)

  19. Human otolith-ocular reflexes during off-vertical axis rotation: effect of frequency on tilt-translation ambiguity and motion sickness

    Science.gov (United States)

    Wood, Scott J.; Paloski, W. H. (Principal Investigator)

    2002-01-01

    The purpose of this study was to examine how the modulation of tilt and translation otolith-ocular responses during constant velocity off-vertical axis rotation varies as a function of stimulus frequency. Eighteen human subjects were rotated in darkness about their longitudinal axis 30 degrees off-vertical at stimulus frequencies between 0.05 and 0.8 Hz. The modulation of torsion decreased while the modulation of horizontal slow phase velocity (SPV) increased with increasing frequency. It is inferred that the ambiguity of otolith afferent information is greatest in the frequency region where tilt (torsion) and translational (horizontal SPV) otolith-ocular responses crossover. It is postulated that the previously demonstrated peak in motion sickness susceptibility during linear accelerations around 0.3 Hz is the result of frequency segregation of ambiguous otolith information being inadequate to distinguish between tilt and translation.

  20. The dynamic performance of narrow actively tilting vehicles

    NARCIS (Netherlands)

    Pauwelussen, J.P.

    2000-01-01

    The major advantage of a motorcycle with respect to a passenger car is the possibility of the driver to tilt during cornering and thereby maintaining stability whereas a passenger car will suffer from the risk of capsizing at high speed. This observation has motivated recently various manufacturers

  1. Dynamic characteristics of polymer faced tilting pad journal bearings

    DEFF Research Database (Denmark)

    Simmons, Gregory F.; Cerda Varela, Alejandro Javier; Santos, Ilmar

    2014-01-01

    Dynamic characteristics of polymer faced tilting pad journal bearings are presented. Investigations are conducted using a single pad, load on pad configuration over a range of shaft speeds and loads. Two polyether ether ketone (PEEK) faced pads, one polytetrafluoroethylene (PTFE) faced pad and tw...

  2. Modelling of LEG tilting pad journal bearings with active lubrication

    DEFF Research Database (Denmark)

    Cerda Varela, Alejandro Javier; García, Asier Bengoechea; Santos, Ilmar

    2017-01-01

    This work constitutes the first step in a research effort aimed at studying the feasibility of introducing an active lubrication concept in tilting pad journal bearings (TPJBs) that feature the leading edge groove (LEG) lubrication system. The modification of the oil flow into each pad supply gro...

  3. Compression paddle tilt correction in full-field digital mammograms.

    NARCIS (Netherlands)

    Kallenberg, M.G.J.; Karssemeijer, N.

    2012-01-01

    During the acquisition of a mammogram the breast is compressed between the compression paddle and the support table. When compression is applied, the upper plate is tilted which results in variation in breast thickness from the chest wall to the breast margin. Variation in breast thickness influence

  4. The dynamic performance of narrow actively tilting vehicles

    NARCIS (Netherlands)

    Pauwelussen, J.P.

    2000-01-01

    The major advantage of a motorcycle with respect to a passenger car is the possibility of the driver to tilt during cornering and thereby maintaining stability whereas a passenger car will suffer from the risk of capsizing at high speed. This observation has motivated recently various manufacturers

  5. Modeling quantitative phase image formation under tilted illuminations.

    Science.gov (United States)

    Bon, Pierre; Wattellier, Benoit; Monneret, Serge

    2012-05-15

    A generalized product-of-convolution model for simulation of quantitative phase microscopy of thick heterogeneous specimen under tilted plane-wave illumination is presented. Actual simulations are checked against a much more time-consuming commercial finite-difference time-domain method. Then modeled data are compared with experimental measurements that were made with a quadriwave lateral shearing interferometer.

  6. Elastohydrodynamics Applied to Active Tilting-Pad Journal Bearings

    DEFF Research Database (Denmark)

    Haugaard, Martin Asger; Santos, Ilmar

    2010-01-01

    The static and dynamic properties of tilting-pad journal bearings with controllable radial oil injection are investigated theoretically. The tilting pads are modeled as flexible structures and their behavior is described using a three-dimensional finite element framework and linear elasticity. Th...... is dynamically perturbed and subsequently condensed to a 2 X 2 system, keeping only the lateral motion of the rotor. As expected, bearing dynamic coefficients are heavily influenced by the control parameters and pad compliance.......The static and dynamic properties of tilting-pad journal bearings with controllable radial oil injection are investigated theoretically. The tilting pads are modeled as flexible structures and their behavior is described using a three-dimensional finite element framework and linear elasticity....... The oil film pressure and flow are considered to follow the modified Reynolds equation, which includes the contribution from controllable radial oil injection. The Reynolds equation is solved using a two-dimensional finite element mesh. The rotor is considered to be rigid in terms of shape and size...

  7. Tilted axis rotation in odd-odd {sup 164}Tm

    Energy Technology Data Exchange (ETDEWEB)

    Reviol, W.; Riedinger, L.L.; Wang, X.Z.; Zhang, J.Y. [Univ. of Tennessee, Knoxville, TN (United States)] [and others

    1996-12-31

    Ten band structures are observed in {sup 164}Tm, among them sets of parallel and anti-parallel couplings of the proton and neutron spins. The Tilted Axis Cranking scheme is applied for the first time to an odd-odd nucleus in a prominent region of nuclear deformation.

  8. Discontinuity effects in dynamically loaded tilting pad journal bearings

    DEFF Research Database (Denmark)

    Thomsen, Kim; Klit, Peder; Vølund, Anders

    2011-01-01

    This paper describes two discontinuity effects that can occur when modelling radial tilting pad bearings subjected to high dynamic loads. The first effect to be treated is a pressure build-up discontinuity effect. The second effect is a contact-related discontinuity that disappears when a contact...

  9. Cellular structures using U_q-tilting modules

    DEFF Research Database (Denmark)

    Andersen, Henning Haahr; Stroppel, Catharina; Tubbenhauer, Daniel

    We use the theory of Uq-tilting modules to construct cellular bases for centralizer algebras. Our methods are quite general and work for any quantum group Uq attached to a Cartan matrix and include the non semi-simple cases for q being a root of unity and ground fields of positive characteristic...

  10. Performance of a Tilt Current Meter in the Surf Zone

    DEFF Research Database (Denmark)

    Hansen, Asger Bendix; Carstensen, Stefan; Christensen, Drude Fritzbøger

    2017-01-01

    Tilt Current Meters (TCM’s) are relatively simple and inexpensive instruments for measuring currents in rivers and inthe sea. Their low cost and easy deployment means that a relatively large number of TCM’s can be deployed comparedto more conventional current meters such as Acoustic Doppler...

  11. Cholesterol orientation and tilt modulus in DMPC bilayers

    OpenAIRE

    Khelashvili, George; Pabst, Georg; Harries, Daniel

    2010-01-01

    We performed molecular dynamics (MD) simulations of hydrated bilayers containing mixtures of dimyristoylphosphatidylcholine (DMPC) and Cholesterol at various ratios, to study the effect of cholesterol concentration on its orientation, and to characterize the link between cholesterol tilt and overall phospholipid membrane organization. The simulations show a substantial probability for cholesterol molecules to transiently orient perpendicular to the bilayer normal, and suggest that cholesterol...

  12. Optical system design with conformal decentered and tilted elements

    Institute of Scientific and Technical Information of China (English)

    Jun Chang; Wubin He; Ruirui Wang; Shulong Feng

    2011-01-01

    @@ We investigate the aberration properties of the conformal optical system with decentered and tilted elements by vector aberration theory.By decentering and tilting the window and corrector of the system,two elements are effectively used together in a particular manner by aberration compensation to achieve off-axis imaging.A conceptual design is performed with a half-field of 2°, the F# of 4, and the wavelength ranging of 3700-4800 nm.The imaging quality can reach the optical diffraction limit and satisfy corresponding requirements.%We investigate the aberration properties of the conformal optical system with decentered and tilted elements by vector aberration theory.By decentering and tilting the window and corrector of the system,two elements are effectively used together in a particular manner by aberration compensation to achieve off-axis imaging.A conceptual design is performed with a half-field of 2°, the F# of 4, and the wavelength ranging of 3700-4800 nm.The imaging quality can reach the optical diffraction limit and satisfy corresponding requirements.

  13. Tilted Thick-Disk Accretion onto a Kerr Black Hole

    Energy Technology Data Exchange (ETDEWEB)

    Fragile, P C; Anninos, P

    2003-12-12

    We present the first results from fully general relativistic numerical studies of thick-disk accretion onto a rapidly-rotating (Kerr) black hole with a spin axis that is tilted (not aligned) with the angular momentum vector of the disk. We initialize the problem with the solution for an aligned, constant angular momentum, accreting thick disk around a black hole with spin a/M = J/M{sup 2} = +0.9 (prograde disk). The black hole is then instantaneously tilted, through a change in the metric, by an angle {beta}{sub 0}. In this Letter we report results with {beta}{sub 0} = 0, 15, and 30{sup o}. The disk is allowed to respond to the Lense-Thirring precession of the tilted black hole. We find that the disk settles into a quasi-static, twisted, warped configuration with Lense-Thirring precession dominating out to a radius analogous to the Bardeen-Petterson transition in tilted Keplerian disks.

  14. Cataract Surgery for Tilted Lens in Peters' Anomaly Type 2

    Directory of Open Access Journals (Sweden)

    Tadayuki Nishide

    2013-09-01

    Full Text Available Background: Cases of cataract surgery without penetrating keratoplasty in patients with Peters' anomaly are very rare. We report a case of Peters' anomaly type 2 with tilted lens due to synechia between the lens and iris that was treated with cataract surgery without penetrating keratoplasty. Case Presentation: A 16-year-old girl had Peters' anomaly in both eyes. Corneal opacity was severe in the left eye due to high-grade dysgenesis of the anterior segment. In the right eye, corneal opacity had spread from the center of the cornea to the inferotemporal side, and there was synechia between the iris and corneal endothelium from the inferonasal side to the inferotemporal side. Opacity was observed in the anterior pole of the lens, and there was synechia between the anterior iris and the lens. Ultrasound biomicroscopy (UBM revealed that the lens was tilted because of synechia. The tilted lens induced astigmatism, which reduced visual acuity to 20/250, in conjunction with a cataract. Cataract surgery was performed; the synechia between the lens capsule and the iris was severed, an intraocular lens was inserted, and the tilt was repaired. UBM was used postoperatively to confirm that the lens capsule synechia had been corrected and that the intraocular lens was not tilted. As a result, visual acuity improved to 20/100; glaucoma and expansion of corneal opacity were not observed. Conclusions: Severing of the synechia between the cataract and iris, during cataract surgery, in a patient with Peters' anomaly type 2 resulted in favorable postoperative visual acuity.

  15. Modeling Flow Past a Tilted Vena Cava Filter

    Energy Technology Data Exchange (ETDEWEB)

    Singer, M A; Wang, S L

    2009-06-29

    Inferior vena cava filters are medical devices used to prevent pulmonary embolism (PE) from deep vein thrombosis. In particular, retrievable filters are well-suited for patients who are unresponsive to anticoagulation therapy and whose risk of PE decreased with time. The goal of this work is to use computational fluid dynamics to evaluate the flow past an unoccluded and partially occluded Celect inferior vena cava filter. In particular, the hemodynamic response to thrombus volume and filter tilt is examined, and the results are compared with flow conditions that are known to be thrombogenic. A computer model of the filter inside a model vena cava is constructed using high resolution digital photographs and methods of computer aided design. The models are parameterized using the Overture software framework, and a collection of overlapping grids is constructed to discretize the flow domain. The incompressible Navier-Stokes equations are solved, and the characteristics of the flow (i.e., velocity contours and wall shear stresses) are computed. The volume of stagnant and recirculating flow increases with thrombus volume. In addition, as the filter increases tilt, the cava wall adjacent to the tilted filter is subjected to low velocity flow that gives rise to regions of low wall shear stress. The results demonstrate the ease of IVC filter modeling with the Overture software framework. Flow conditions caused by the tilted Celect filter may elevate the risk of intrafilter thrombosis and facilitate vascular remodeling. This latter condition also increases the risk of penetration and potential incorporation of the hook of the filter into the vena caval wall, thereby complicating filter retrieval. Consequently, severe tilt at the time of filter deployment may warrant early clinical intervention.

  16. Novel tilt-curvature coupling in lipid membranes

    Science.gov (United States)

    Terzi, M. Mert; Deserno, Markus

    2017-08-01

    On mesoscopic scales, lipid membranes are well described by continuum theories whose main ingredients are the curvature of a membrane's reference surface and the tilt of its lipid constituents. In particular, Hamm and Kozlov [Eur. Phys. J. E 3, 323 (2000)] have shown how to systematically derive such a tilt-curvature Hamiltonian based on the elementary assumption of a thin fluid elastic sheet experiencing internal lateral pre-stress. Performing a dimensional reduction, they not only derive the basic form of the effective surface Hamiltonian but also express its emergent elastic couplings as trans-membrane moments of lower-level material parameters. In the present paper, we argue, though, that their derivation unfortunately missed a coupling term between curvature and tilt. This term arises because, as one moves along the membrane, the curvature-induced change of transverse distances contributes to the area strain—an effect that was believed to be small but nevertheless ends up contributing at the same (quadratic) order as all other terms in their Hamiltonian. We illustrate the consequences of this amendment by deriving the monolayer and bilayer Euler-Lagrange equations for the tilt, as well as the power spectra of shape, tilt, and director fluctuations. A particularly curious aspect of our new term is that its associated coupling constant is the second moment of the lipid monolayer's lateral stress profile—which within this framework is equal to the monolayer Gaussian curvature modulus, κ¯ m. On the one hand, this implies that many theoretical predictions now contain a parameter that is poorly known (because the Gauss-Bonnet theorem limits access to the integrated Gaussian curvature); on the other hand, the appearance of κ¯ m outside of its Gaussian curvature provenance opens opportunities for measuring it by more conventional means, for instance by monitoring a membrane's undulation spectrum at short scales.

  17. Graded mutation in cluster categories coming from hereditary categories with a tilting object

    CERN Document Server

    Bertani-Økland, Marco Angel; Wrålsen, Anette

    2010-01-01

    We present a graded mutation rule for quivers of cluster-tilted algebras. Furthermore, we give a technique to recover a cluster-tilting object from its graded quiver in the cluster category of coh $\\mathbb{X}$.

  18. Cross-Modal Transfer of the Tilt Aftereffect From Vision to Touch

    Science.gov (United States)

    Krystallidou, Dafni

    2016-01-01

    Visual input powerfully modulates the dynamics of tactile orientation perception. This study investigated the transfer of the tilt aftereffect (TAE) from vision to somatosensation. In a visual tilt adaptation paradigm, participants were exposed to clockwise or anticlockwise visual tilt, followed by three brief tactile two-point stimuli delivered on their forehead. In a two-alternative forced choice task, participants had to indicate whether the haptic stimulus was tilted to the right or left. Repeated exposure to oriented visual gratings produced a tactile TAE, such that the subsequent tactile stimuli appeared tilted toward the opposite direction. To assess the origin of this effect, the experiment was repeated with the head tilted. Adaptation to a gravitationally tilted grating but with the head tilted so that the grating was retinally vertical induced a robust tactile aftereffect suggesting that the visuotactile TAE is due to spatiotopic rather than retinotopic adaptation.

  19. Lesion classification using 3D skin surface tilt orientation.

    Science.gov (United States)

    She, Zhishun; Excell, P S

    2013-02-01

    Current non-invasive diagnostic procedures to detect skin cancer rely on two-dimensional (2D) views of the skin surface. For example, the most commonly-used ABCD features are extracted from the 2D images of skin lesion. However, because the skin surface is an object in three-dimensional (3D) space, valuable additional information can be obtained from a perspective of 3D skin objects. The aim of this work is to discover the new diagnostic features by considering 3D views of skin artefacts. A surface tilt orientation parameter was proposed to quantify the skin and the lesion in 3D space. The skin pattern was first extracted from simply captured white light optical clinical (WLC) skin images by high-pass filtering. Then the directions of the projected skin lines were determined by skin pattern analysis. Next the surface tilt orientations of skin and lesion were estimated using the shape from texture technique. Finally the difference of tilt orientation in the lesion and normal skin areas, combined with the ABCD features, was used as a lesion classifier. The proposed method was validated by processing a set of images of malignant melanoma and benign naevi. The scatter plot of classification using the feature of surface tilt orientation alone showed the potential of the new 3D feature, enclosing an area of 0.78 under the ROC curve. The scatter plot of classification, combining the new feature with the ABCD features by use of Principal Component Analysis (PCA), demonstrated an excellent separation of benign and malignant lesions. An ROC plot for this case enclosed an area of 0.85. Compared with the ABCD analysis where the area under the ROC curve was 0.65, it indicated that the surface tilt orientation (3D information) was able to enhance the classification results significantly. The initial classification results show that the surface tilt orientation has a potential to increase lesion classifier accuracy. Combined with the ABCD features, it is very promising to

  20. Effect of tilting on cerebral hemodynamics in preterm and term infants

    NARCIS (Netherlands)

    Pichler, G; van Boetzelar, MC; Muller, W; Urlesberger, B

    2001-01-01

    Tilting is known to cause changes in hemodynamics due to hydrostatic pressure. The present study is an analysis of changes in cerebral hemodynamics measured by near infrared spectroscopy (NIRS) following tilting up and down in preterm and term infants. A significantly different effect of tilting up

  1. Improvement of Head-Up Display Standards. Volume 1. Head-Up Display Design Guide. Appendix

    Science.gov (United States)

    1987-09-01

    the angle between an aircraft longitudinal reference (FRL or ACPL) and the air velocity vector projected on the plane defined by the aircraft ...longitudinal axes. 11. ANGLE OF SIDESLIP (BETA): The angle of sideslip is the angle between the aircraft longitudinal reference (FRL or ACRL) and the air...velocity vector projected on the plane defined by the aircraft longitudinal reference and the aircraft lateral ax- is. BETA is the left-right equivalent of

  2. Three-dimensional microelectromechanical tilting platform operated by gear-driven racks

    Science.gov (United States)

    Klody, Kelly A.; Habbit, Jr., Robert D.

    2005-11-01

    A microelectromechanical (MEM) tiltable-platform apparatus is disclosed which utilizes a light-reflective platform (i.e. a micromirror) which is supported above a substrate by flexures which can be bent upwards to tilt the platform in any direction over an angle of generally .+-.10 degrees using a gear-driven rack attached to each flexure. Each rack is driven by a rotary microengine (i.e. a micromotor); and an optional thermal actuator can be used in combination with each microengine for initially an initial uplifting of the platform away from the substrate. The MEM apparatus has applications for optical switching (e.g. between a pair of optical fibers) or for optical beam scanning.

  3. STS-44 DSP / IUS spacecraft tilted to deployment position in OV-104's PLB

    Science.gov (United States)

    1991-01-01

    STS-44 Defense Support Program (DSP) / Inertial Upper Stage (IUS) spacecraft, with forward airborne support equipment (ASE) payload retention latch actuator and umbilical boom released, is raised to a 58 degree deployment position by the ASE aft frame tilt actuator (AFTA) table in the payload bay (PLB) of Atlantis, Orbiter Vehicle (OV) 104. The IUS is supported in the ASE AFTA table and is inscribed with USAF. Above the IUS is the DSP satellite with stowed solar paddles (box-like structure) visible just above the DSP/IUS interface. The cylinder at the very top of the DSP satellite is the Infrared (IR) Sensor. Lights illuminate the PLB and highlight the IUS and some DSP components against the blackness of space.

  4. Comparison with Tilted Axis Cranking and particle rotor model for triaxial nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Ohtsubo, Shin-ichi; Shimizu, Yoshifumi R. [Kyushu Univ., Fukuoka (Japan). Dept. of Physics

    1998-03-01

    An extension of the cranking model in such a way to allow a rotation axis to deviate from the principal axes of the deformed mean-field is a promising tool for the spectroscopic study of rapidly rotating nuclei. We have applied such a `Tilted Axis Cranking` (TAC) method to a simple system of one-quasiparticle coupled to a triaxial rotor and compared it with a particle-rotor coupling calculation in order to check whether the spin-orientation degrees of freedom can be well described within the mean-field approximation. The result shows that the TAC method gives a good approximation to observable quantities and it is a suitable method to understand the dynamical interplay between the collective and single-particle angular momenta. (author)

  5. Modeling of glycerol-3-phosphate transporter suggests a potential 'tilt' mechanism involved in its function.

    Science.gov (United States)

    Tsigelny, Igor F; Greenberg, Jerry; Kouznetsova, Valentina; Nigam, Sanjay K

    2008-10-01

    Many major facilitator superfamily (MFS) transporters have similar 12-transmembrane alpha-helical topologies with two six-helix halves connected by a long loop. In humans, these transporters participate in key physiological processes and are also, as in the case of members of the organic anion transporter (OAT) family, of pharmaceutical interest. Recently, crystal structures of two bacterial representatives of the MFS family--the glycerol-3-phosphate transporter (GlpT) and lac-permease (LacY)--have been solved and, because of assumptions regarding the high structural conservation of this family, there is hope that the results can be applied to mammalian transporters as well. Based on crystallography, it has been suggested that a major conformational "switching" mechanism accounts for ligand transport by MFS proteins. This conformational switch would then allow periodic changes in the overall transporter configuration, resulting in its cyclic opening to the periplasm or cytoplasm. Following this lead, we have modeled a possible "switch" mechanism in GlpT, using the concept of rotation of protein domains as in the DynDom program17 and membranephilic constraints predicted by the MAPAS program.(23) We found that the minima of energies of intersubunit interactions support two alternate positions consistent with their transport properties. Thus, for GlpT, a "tilt" of 9 degrees -10 degrees rotation had the most favorable energetics of electrostatic interaction between the two halves of the transporter; moreover, this confirmation was sufficient to suggest transport of the ligand across the membrane. We conducted steered molecular dynamics simulations of the GlpT-ligand system to explore how glycerol-3-phosphate would be handled by the "tilted" structure, and obtained results generally consistent with experimental mutagenesis data. While biochemical data remain most consistent with a single-site alternating access model, our results raise the possibility that, while the

  6. Three-Dimensional Waves in Tilt Thermal Boundary Layers

    Institute of Scientific and Technical Information of China (English)

    TAO Jian-Jun; YUAN Xiang-Jiang

    2009-01-01

    We numerically and theoretically study the stabilities of tilt thermal boundary layers immersed in stratified air. An interesting phenomenon is revealed: the stationary longitudinal-roll mode becomes unstable to some oscillating state even when the Grashof number is smaller than its corresponding critical value. By stability analysis, this phenomenon is explained in terms of a new three-dimensional wave mode. The effect of the tilt angle on the stability of the boundary flows is investigated. Since the new three-dimensional wave is found to be the most unstable mode when the title angle is between 30° and 64°, it is expected to play an important role in the transition to turbulence.

  7. Tilting-Pad Guide Bearing in Large Hydro-unit

    Directory of Open Access Journals (Sweden)

    Li-Feng Ma

    2000-01-01

    Full Text Available A new numerical method is proposed for predicting the nonlinearity of tilting-pad guide bearing oilfilm force in the rotor-bearing system in a large hydro-unit. Nonlinear displacement and velocity of the journal center, as well as nonlinear tilting angles and angular velocities of the pads in non-stationary Reynolds equation are taken into account. This method is also suited for other small rotor-bearing system. As an example, the response due to a momentarily created unbalance is Calculated. The nonlinear motion patterns of the pad and journal whirling orbit are obtained. Finally, the nonlinear orbit is compared to the linear one that could be calculated from linear stiffness and damping coefficients. It is shown that there are important differences between those two orbits and that the nonlinear simulation is more accurate.

  8. Atomic arrangement and charge distribution in YBCO tilt grain boundaries

    Science.gov (United States)

    Bording, J. K.; Halley, J. W.; Zhu, Y.

    2005-03-01

    It is well known that the critical current, Jc, in high-Tc superconductors is reduced at grain boundaries. Recent high resolution holography experiments show the [100] tilt grain boundaries in YBa2Cu3O7-x to have an excess negative charge localized at the boundary dislocation core. Upon doping with Ca, this charge is reduced and the critical current increased. To shed light on this behavior at an atomic scale, we carried out Tight Binding (TB) calculations of these boundaries. Our TB scheme is charge self consistent to allow charge transfer typical for ionic materials. We present the arrangement of atoms and charge in YBCO tilt grain boundaries as determined by a combination of TB calculations, recent high resolution Scanning Transmission Electron Microscopy and Electron Energy Loss Spectroscopy measurements.

  9. Tilt correction method of text image based on wavelet pyramid

    Science.gov (United States)

    Yu, Mingyang; Zhu, Qiguo

    2017-04-01

    Text images captured by camera may be tilted and distorted, which is unfavorable for document character recognition. Therefore,a method of text image tilt correction based on wavelet pyramid is proposed in this paper. The first step is to convert the text image captured by cameras to binary images. After binarization, the images are layered by wavelet transform to achieve noise reduction, enhancement and compression of image. Afterwards,the image would bedetected for edge by Canny operator, and extracted for straight lines by Radon transform. In the final step, this method calculates the intersection of straight lines and gets the corrected text images according to the intersection points and perspective transformation. The experimental result shows this method can correct text images accurately.

  10. Profile stabilization of tilt mode in a Field Reversed Configuration

    Energy Technology Data Exchange (ETDEWEB)

    Cobb, J.W.; Tajima, T. [Texas Univ., Austin, TX (United States). Inst. for Fusion Studies; Barnes, D.C. [Los Alamos National Lab., NM (United States)

    1993-06-01

    The possibility of stabilizing the tilt mode in Field Reversed Configurations without resorting to explicit kinetic effects such as large ion orbits is investigated. Various pressure profiles, P({Psi}), are chosen, including ``hollow`` profiles where current is strongly peaked near the separatrix. Numerical equilibria are used as input for an initial value simulation which uses an extended Magnetohydrodynamic (MHD) model that includes viscous and Hall terms. Tilt stability is found for specific hollow profiles when accompanied by high values of separatrix beta, {beta}{sub sep}. The stable profiles also have moderate to large elongation, racetrack separatrix shape, and lower values of 3, average ratio of Larmor radius to device radius. The stability is unaffected by changes in viscosity, but the neglect of the Hall term does cause stable results to become marginal or unstable. Implications for interpretation of recent experiments are discussed.

  11. On the Design of Tilting-Pad Thrust Bearings

    DEFF Research Database (Denmark)

    Heinrichson, Niels

    2007-01-01

    Pockets are often machined in the surfaces of tilting-pad thrust bearings to allow for hydrostatic jacking in the start-up phase. Pockets and other recesses in the surfaces of bearing pads influence the pressure distribution and thereby the position of the pivot resulting in the most advantageous...... friction and a small pressure build-up. As in parallel-step bearings the recesses may also have a depth of the same order of magnitude as the oil film thickness. Such recesses are characterized by a strong pressure build-up caused by the reduction of the flow area at the end of the recess. Numerical models...... based on the Reynolds equation are used. They include the effects of variations of viscosity with temperature and the deformation of the bearing pads due to pressure and thermal gradients. The models are validated using measurements. Tilting-pad bearings of standard design are studied and the influences...

  12. Can pelvic tilting be ignored in total hip arthroplasty?

    Directory of Open Access Journals (Sweden)

    Won Yong Shon

    2014-01-01

    CONCLUSION: The sagittal position of pelvis is a key factor in impingement and dislocation after total hip arthroplasty. Pelvic tilting affects the position of acetabular component in the sagittal plane of the body as compared with its anatomic position in the pelvis. We suggest a preoperative lateral view of spine-pelvis, in upright and supine position for evaluation of a corrective adaptation of the acetabular cup accordingly with pelvic balance.

  13. An entry in the great frame-tilt judging contest.

    Science.gov (United States)

    Goodenough, D R

    1981-02-01

    Some important questions about discrepancies between observer-perceived and investigator-defined direction of frame tilt are raised by Fine in his recent note on procedures used in the rod-and-frame test of field dependence. The practical and conceptual implications of these discrepancies are discussed in the present article in the context of Witkin's field-dependence theory and of recent findings on the nature of the rod-and-frame illusion.

  14. Linear Coupling for B-Factory Tilted Solenoid

    Energy Technology Data Exchange (ETDEWEB)

    Fedotov, A.

    2005-02-16

    In this thesis they have presented the transfer matrix for B Factory tilted solenoid with the expansion of magnetic field up to the fifth order. Starting with the general theory of linear coupling, we got the Hamiltonian for solenoid with the bending magnet and quadrupole inside. The solenoid axis is tilted by 20 mrad horizontally w.r.t. the collision axis and at the entrance and the exit of the solenoid the beam will sense transverse and longitudinal non-linear fields. To account both this effects the expansion of the magnetic field was done. The code of coordinate transformation, which relates the frame of the reference orbit to the frame of the collision axis and to the solenoid frame, has been introduced. They tried to show that not symplectic fourth-order Runge Kutta integration method, which had been used for integration of the Hamiltonian equations, might be used as a model for ''not tracking'' problems. The deviation from a symplectic transfer matrix is smaller than 10{sup -5}. Using the transfer matrix, the change in beam shape and blow up of emittance, due to the solenoid coupling, was discussed. In order to compensate this effect they used 4 tilted quadrupoles on each side of the IP. The method based on the Hamiltonian in Eq.19 integrates along a reference orbit which is defined only by the horizontal and vertical bending fields and not by the tilted solenoid. In order to get the Hamiltonian, which is associated with a non-planar curvature of the reference orbit, it is necessary to account the effect of torsion. In that case the transformation between the three different coordinate systems will become more complicated.

  15. Carbon dioxide waveguide lasers with folds and tilted mirrors

    Energy Technology Data Exchange (ETDEWEB)

    Hill, C.A.; Jackson, P.E. (Heriot-Watt University, Physics Department, Optoelectronics Lasar Engineering, Edinburgh EH14 4AS, U.K. (GB)); Hall, D. (Royal Signals Radar Establishment, Malvern, Worcs WR14 3PS, (UK))

    1990-05-20

    We present theoretical and experimental results for an rf-excited z-fold CO{sub 2} waveguide laser. We describe how the output power, output rotational line(s) and transverse mode(s) vary as functions of elbow mirror tilt and obtain good agreement with predictions from a multimode matrix resonator model. Observations of multilining and/or multifrequency operation are partly explained by the near equality of gain/loss ratios for two or more resonator modes.

  16. Tilting mutation of weakly symmetric algebras and stable equivalence

    CERN Document Server

    Dugas, Alex

    2011-01-01

    We consider tilting mutations of a weakly symmetric algebra at a subset of simple modules, as recently introduced by T. Aihara. These mutations are defined as the endomorphism rings of certain tilting complexes of length 1. Starting from a weakly symmetric algebra A, presented by a quiver with relations, we give a detailed description of the quiver and relations of the algebra obtained by mutating at a single loopless vertex of the quiver of A. In this form the mutation procedure appears similar to, although significantly more complicated than, the mutation procedure of Derksen, Weyman and Zelevinsky for quivers with potentials. By definition, weakly symmetric algebras connected by a sequence of tilting mutations are derived equivalent, and hence stably equivalent. The second aim of this article is to describe explicitly the images of the simple modules under such a stable equivalence. As an application we answer a question of Asashiba on the derived Picard groups of a class of symmetric algebras of finite re...

  17. Tilted Two-Dimensional Array Multifocus Confocal Raman Microspectroscopy.

    Science.gov (United States)

    Yabumoto, Sohshi; Hamaguchi, Hiro-O

    2017-07-18

    A simple and efficient two-dimensional multifocus confocal Raman microspectroscopy featuring the tilted-array technique is demonstrated. Raman scattering from a 4 × 4 square foci array passing through a 4 × 4 confocal pinhole array is tilted with a periscope. The tilted array of Raman scattering signals is dispersed by an imaging spectrograph onto a CCD detector, giving 16 independent Raman spectra formed as 16 bands with different heights on the sensor. Use of a state-of-the-art imaging spectrograph enables high-precision wavenumber duplicability of the 16 spectra. This high duplicability makes the simultaneously obtained spectra endurable for multivariate spectral analyses, which is demonstrated by a singular value decomposition analysis for Raman spectra of liquid indene. Although the present implementation attains only 16 measurement points, the number of points can be extended to larger than 100 without any technical leaps. Limit of parallelization depends on the interval of measurement points as well as the performance of the optical system. Criteria for finding the maximum feasible number are discussed.

  18. Tilted Lema\\^itre model and the dark flow

    CERN Document Server

    Fernández, J

    2013-01-01

    In the last years, the peculiar velocities of many X-ray galaxies clusters with respect to the distance have been measured directly in the rest frame of the cosmic microwave background radiation (CBR), using the kinematic Sunyaev-Zeldovich (kSZ) effect. These measures prove that exists a highly coherent motion, extending out to at least to ~1 Gpc, of the matter rest frame with respect to the CBR rest frame. This global motion was named "dark flow". By using an inhomogeneous spherically symmetric "tilted" Lema\\^itre model, we could explain the dark flow if we assume a linear increase with distance of the peculiar velocities, which is in principle allowed by these observations. This linear increase of the dark flow with the distance has the same behavior that the intrinsic dipole, due to the kinematic acceleration, which appears in the Hubble law of the Lema\\^itre model. In the "tilted" Lema\\^itre model considered, we consider that the radiation orthogonal congruence is a perfect fluid and the matter "tilted" c...

  19. Analytic crack solutions for tilt fields around hydraulic fractures

    Energy Technology Data Exchange (ETDEWEB)

    Warpinski, N.R.

    2000-01-05

    The recent development of downhole tiltmeter arrays for monitoring hydraulic fractures has provided new information on fracture growth and geometry. These downhole arrays offer the significant advantages of being close to the fracture (large signal) and being unaffected by the free surface. As with surface tiltmeter data, analysis of these measurements requires the inversion of a crack or dislocation model. To supplement the dislocation models of Davis [1983], Okada [1992] and others, this work has extended several elastic crack solutions to provide tilt calculations. The solutions include constant-pressure 2D, penny-shaped, and 3D-elliptic cracks and a 2D-variable-pressure crack. Equations are developed for an arbitrary inclined fracture in an infinite elastic space. Effects of fracture height, fracture length, fracture dip, fracture azimuth, fracture width and monitoring distance on the tilt distribution are given, as well as comparisons with the dislocation model. The results show that the tilt measurements are very sensitive to the fracture dimensions, but also that it is difficult to separate the competing effects of the various parameters.

  20. Polygonal Area of Prosthesis Support with Straight and Tilted Dental Implants in Edentulous Maxillae.

    Science.gov (United States)

    Wentaschek, Stefan; Lehmann, Karl Martin; Scheller, Herbert; Weibrich, Gernot; Behneke, Nikolaus

    2016-01-01

    The aim of this in vitro study was to assess the increase in the polygonal area of implant-retained prosthesis supports in edentulous maxillae with the use of tilted distal implants compared with the use of straight distal implants, using a variety of implant lengths. A total of 25 DICOM datasets of atrophic edentulous maxillae were provided. Bone augmentations in the molar region had to be avoided. Two straight reference implants were virtually inserted in the anterior region. Two additional implants were placed far distally on both sides (4 groups: [1] straight, 12-mm length; [2] straight, 10 mm; [3] straight, 8 mm; [4] tilted, 12-16 mm). The resulting implant-supported polygon was measured for each of the 4 groups using three-dimensional planning software. The mean sagittal depth of the supported polygon in Group 1 was 9.9 mm (standard deviation [SD] 4.4) on the right and 10.2 mm (SD 4.4) on the left, and it was 33.7 mm (SD 5.8) in width. For Group 2, the mean sagittal depth was 11.5 mm (SD 5.0) on the right and 11.9 mm (SD 4.7) on the left, and the width was 35.2 mm (SD 5.6). The measurements for Group 3 were 13.8 mm (SD 4.9) deep on the right, 13.8 mm (SD 5.1) deep on the left, and 37.0 mm (SD 5.4) in width. For Group 4, the depth was 15.8 mm (SD 4.9) on the right and 16.4 mm (SD 5.8) on the left, and the width was 39.0 mm (SD 5.1). The area of implant-retained prosthesis support can be enlarged by the use of tilted implants (12 to 16 mm in length, 42 to 45 degrees) compared to the use of straight 8-mm implants (resulting increase: about 15%).

  1. Inverse Degree and Connectivity

    Institute of Scientific and Technical Information of China (English)

    MA Xiao-ling; TIAN Ying-zhi

    2013-01-01

    Let G be a connected graph with vertex set V(G),order n =丨V(G)丨,minimum degree δ(G) and connectivity κ(G).The graph G is called maximally connected if κ(G) =δ(G).Define the inverse degree of G with no isolated vertices as R(G) =Σv∈V(G)1/d(v),where d(v) denotes the degree of the vertex v.We show that G is maximally connected if R(G) < 1 + 2/δ + n-2δ+1/(n-1)(n-3).

  2. Fast auto-acquisition tomography tilt series by using HD video camera in ultra-high voltage electron microscope.

    Science.gov (United States)

    Nishi, Ryuji; Cao, Meng; Kanaji, Atsuko; Nishida, Tomoki; Yoshida, Kiyokazu; Isakozawa, Shigeto

    2014-11-01

    series of 61 images within 30 minutes. Accuracy and repeatability were good enough to practical use (Figure 1). We successfully reduced the total acquisition time of a tomography tilt series in half than before.jmicro;63/suppl_1/i25/DFU066F1F1DFU066F1Fig. 1.Objective lens current change with a tilt angle during acquisition of tomography series (Sample: a rat hepatocyte, thickness: 2 m, magnification: 4k, acc. voltage: 2 MV). Tilt angle range is ±60 degree with 2 degree step angle. Two series were acquired in the same area. Both data were almost same and the deviation was smaller than the minimum step by manual, so auto-focus worked well. We also developed a computer-aided three dimensional (3D) visualization and analysis software for electron tomography "HawkC" which can sectionalize the 3D data semi-automatically[5,6]. If this auto-acquisition system is used with IMOD reconstruction software[7] and HawkC software, we will be able to do on-line UHVEM tomography. The system would help pathology examination in the future.This work was supported by the Ministry of Education, Culture, Sports, Science and Technology (MEXT), Japan, under a Grant-in-Aid for Scientific Research (Grant No. 23560024, 23560786), and SENTAN, Japan Science and Technology Agency, Japan.

  3. The influence of head and body tilt on human fore-aft translation perception

    Science.gov (United States)

    Crane, Benjamin T.

    2016-01-01

    The tilt-translation ambiguity occurs because acceleration due to translation cannot be differentiated from gravitational acceleration. Head tilt can occur independent of body tilt which further complicates the problem. The tilt-translation ambiguity is examined for fore-aft (surge) translation with head and/or body orientations that are tilted in pitch 10° forward or backward. Eleven human subjects (6 female), mean age 40 years participated. Conditions included no tilt (NT), head and body tilt (HBT), head only tilt (HOT), and body only tilt (BOT). The fore-aft stimulus consisted of a 2s (0.5 Hz) sine wave in acceleration which a maximum peak velocity of 10 cm/s. After each stimulus the subject reported the direction of motion as forward or backward. Subsequent stimuli were adjusted to determine the point at which subjects were equally likely to report motion in either direction. During the HBT responses were biased such that upward pitch caused a neutral stimulus to be more likely to be perceived as forward and downward pitch caused the stimulus to be more likely to be perceived as backward. The difference in the point of subjective equality based on the direction of tilt was 3.3 cm/s. During the BOT condition the bias with respect to the direction of body tilt was in a similar direction with a difference in PSE 1.6 cm/s. During HOT and NT there was no significant bias on fore-aft perception. These findings demonstrate that body tilt shifts the PSE of fore-aft direction discrimination while head tilt has no influence. PMID:25160866

  4. Focus variation microscope: linear theory and surface tilt sensitivity.

    Science.gov (United States)

    Nikolaev, Nikolay; Petzing, Jon; Coupland, Jeremy

    2016-05-01

    In a recent publication [3rd International Conference on Surface Metrology, Annecy, France, 2012, p. 1] it was shown that surface roughness measurements made using a focus variation microscope (FVM) are influenced by surface tilt. The effect appears to be most significant when the surface has microscale roughness (Ra≈50  nm) that is sufficient to provide a diffusely scattered signal that is comparable in magnitude to the specular component. This paper explores, from first principles, image formation using the focus variation method. With the assumption of incoherent scattering, it is shown that the process is linear and the 3D point spread characteristics and transfer characteristics of the instrument are well defined. It is argued that for the case of microscale roughness and through the objective illumination, the assumption of incoherence cannot be justified and more rigorous analysis is required. Using a foil model of surface scattering, the images that are recorded by a FVM have been calculated. It is shown that for the case of through-the-objective illumination at small tilt angles, the signal quality is degraded in a systematic manner. This is attributed to the mixing of specular and diffusely reflected components and leads to an asymmetry in the k-space representation of the output signals. It is shown that by using extra-aperture illumination or tilt angles greater than the acceptance angle of aperture (such that the specular component is lost), the incoherent assumption can be justified once again. The work highlights the importance of using ring-light illumination and/or polarizing optics, which are often available as options on commercial instruments, as a means to mitigate or prevent these effects.

  5. Rationale for tilted implants: FEA considerations and clinical reports.

    Science.gov (United States)

    DE Vico, G; Bonino, M; Spinelli, D; Schiavetti, R; Sannino, G; Pozzi, A; Ottria, L

    2011-07-01

    The prevalence of the elderly population, as well as life expectancy, increased in the final decades of the 20th century, as described in the World Health Organization 2004 Annual Report. The edentulous condition therefore has a negative impact on the oral health-related quality of life. Patients wearing complete dentures for many years infact, and especially in the mandible, are often unsatisfied because of the instability of the prosthesis during speaking and eating. To date dental implant treatment is well documented as a predictable treatment for partial or complete edentulism. On the other hand the rehabilitation of atrophied edentulous arches with endosseous implants (> 10 mm) in the posterior regions is often associated with anatomic problems such as bone resorption, poor bone quality, mandibular canal, and the presence of maxillary sinuses. Different procedures have been proposed to overcome these anatomic limitations. The use of tilted implants parallel to the anterior wall of the maxillary sinus or the mental foramen/inferior alveolar nerve has been proposed as a conservative solution for the treatment of the atrophic edentulous maxilla. Aim of this study was to describe, through a detailed literature review, the clinical and biomechanical rationale for tilting implants and to evaluate the long-term prognosis of immediately loaded full fixed prostheses for the treatment of edentulous patients (#35) with extreme bone atrophy rehabilited with both axial (#70) and tilted (#70) implants from 2008 to 2010. The results of the present study would suggest that this new surgical technique may reduce patient morbidity and extend the indications for immediate loading full fixed rehabilitations. This improves the predictability of treatment goal, allows for a better risk management, and provides more individual information for the patient. These are the most important aspects of this technology, which may contribute to establish higher-quality standards in

  6. Sunspot positions, areas, and group tilt angles for 1611-1631 from observations by Christoph Scheiner

    Science.gov (United States)

    Arlt, R.; Senthamizh Pavai, V.; Schmiel, C.; Spada, F.

    2016-11-01

    Aims: Digital images of observations printed in the books Rosa Ursina sive solis and Prodromus pro sole mobili by Christoph Scheiner, as well as the drawings from Scheiner's letters to Marcus Welser, are analysed to obtain information on the positions and sizes of sunspots that appeared before the Maunder minimum. Methods: In most cases, the given orientation of the ecliptic is used to set up the heliographic coordinate system for the drawings. Positions and sizes are measured manually on screen. Very early drawings have no indication of their orientation. A rotational matching using common spots of adjacent days is used in some cases, while in other cases, the assumption that images were aligned with a zenith-horizon coordinate system appeared to be the most probable. Results: In total, 8167 sunspots were measured. A distribution of sunspot latitudes versus time (butterfly diagram) is obtained for Scheiner's observations. The observations of 1611 are very inaccurate, the drawings of 1612 have at least an indication of their orientation, while the remaining part of the spot positions from 1618-1631 have good to very good accuracy. We also computed 697 tilt angles of apparently bipolar sunspot groups observed in the period 1618-1631. We find that the average tilt angle of nearly 4 degrees is not significantly different from 20th-century values. Data on the sunspot position and area are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/595/A104

  7. Viscous tilting and production of vorticity in homogeneous turbulence

    Science.gov (United States)

    Holzner, M.; Guala, M.; Lüthi, B.; Liberzon, A.; Nikitin, N.; Kinzelbach, W.; Tsinober, A.

    2010-06-01

    Viscous depletion of vorticity is an essential and well known property of turbulent flows, balancing, in the mean, the net vorticity production associated with the vortex stretching mechanism. In this letter, we, however, demonstrate that viscous effects are not restricted to a mere destruction process, but play a more complex role in vorticity dynamics that is as important as vortex stretching. Based on the results from three dimensional particle tracking velocimetry experiments and direct numerical simulation of homogeneous and quasi-isotropic turbulence, we show that the viscous term in the vorticity equation can also locally induce production of vorticity and changes of the orientation of the vorticity vector (viscous tilting).

  8. Viscous tilting and production of vorticity in homogeneous turbulence

    CERN Document Server

    Holzner, M; Lüthi, B; Liberzon, A; Nikitin, N; Kinzelbach, W; Tsinober, A

    2010-01-01

    Viscous depletion of vorticity is an essential and well known property of turbulent flows, balancing, in the mean, the net vorticity production associated with the vortex stretching mechanism. In this letter we however demonstrate that viscous effects are not restricted to a mere destruction process, but play a more complex role in vorticity dynamics that is as important as vortex stretching. Based on results from particle tracking experiments (3D-PTV) and direct numerical simulation (DNS) of homogeneous and quasi isotropic turbulence, we show that the viscous term in the vorticity equation can also locally induce production of vorticity and changes of its orientation (viscous tilting).

  9. Tilt table testing in patients with suspected epilepsy1

    DEFF Research Database (Denmark)

    Edfors, R.; Erdal, J.; Rogvi-Hansen, B.

    2008-01-01

    BACKGROUND: Approximately 20-30% of patients with epilepsy are misdiagnosed and syncope often seems to be the mistaken cause. We re-evaluated patients referred to an epilepsy clinic where suspicion of neurally mediated (reflex) syncope were raised using tilt table testing (HUT). METHODS: HUT...... laboratory results and medical records of 120 consecutive patients were reviewed retrospectively over a period of 27 months. RESULTS: HUT was positive in 59 (49%) patients. Seventeen of 38 (45%) patients previously diagnosed with epilepsy and taking antiepileptic drugs were found to be misdiagnosed. Four...

  10. Tilted versus axially placed dental implants: a meta-analysis.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Albrektsson, Tomas; Wennerberg, Ann

    2015-02-01

    The purpose of the present review was to test the null hypothesis of no difference in the implant failure rate, marginal bone loss, and postoperative infection for patients being rehabilitated by tilted or by axially placed dental implants, against the alternative hypothesis of a difference. An electronic search without time or language restrictions was undertaken in July 2014. Eligibility criteria included clinical human studies, either randomised or not, interventional or observational. The estimates of an intervention were expressed in risk ratio (RR) and mean difference (MD) in millimetres. The search strategy resulted in 44 publications. A total of 5029 dental implants were tilted (82 failures; 1.63%), and 5732 implants were axially placed (104 failures; 1.81%). The difference between the procedures did not significantly affect the implant failure rates (P=0.40), with a RR of 1.14 (95% CI 0.84-1.56). A statistically significant difference was found for implant failures when studies evaluating implants inserted in maxillae only were pooled (RR 1.70, 95% CI 1.05-2.74; P=0.03), the same not happening for the mandible (RR 0.77, 95% CI 0.39-1.52; P=0.45). There were no apparent significant effects of tilted dental implants on the occurrence of marginal bone loss (MD 0.03, 95% CI -0.03 to 0.08; P=0.32). Due to lack of satisfactory information, meta-analysis for the outcome 'postoperative infection' was not performed. It is suggested that the differences in angulation of dental implants might not affect the implant survival or the marginal bone loss. The reliability and validity of the data collected and the potential for biases and confounding factors are some of the shortcomings of the present study. The question whether tilted implants are more at risk for failure than axially placed implants has received increasing attention in the last years. As the philosophies of treatment alter over time, a periodic review of the different concepts is necessary to refine

  11. Measuring the Virgo area tilt noise with a laser gyroscope

    CERN Document Server

    Belfi, Jacopo; Bosi, Filippo; Carelli, Giorgio; Di Virgilio, Angela; Maccioni, Enrico; Stefani, Fabio

    2011-01-01

    We report on the measurements of tilt noise performed at the Virgo site with a ring laser gyroscope. The apparatus is a He-Ne laser operating in a square cavity mounted on a vertical plane perpendicular to the north-south arm of the inteferometer. We discuss the possibility of using the ring laser signal to improve the performances of the control system of the Virgo seismic suspensions. The comparison between the ring laser signal and the control signals for the longitudinal translations of the inverted pendulum (IP) shows remarkable coherence in the frequency range 20-200 mHz.

  12. Tilted bending magnet for SPS target area TCC2

    CERN Multimedia

    1976-01-01

    A slow-extracted proton beam from the SPS goes to the underground target zone TCC2. The part of the primary beam which traverses target T4 is recuperated and transported over some 800 m, for further use in the North Area High Intensity facility (NAHIF). The curved and sloped trajectory required 4 of the bending magnets to be tilted. Here we see one of them being attended by Gilbert Françon in hall 867, ready for installation in TCC2.

  13. Degree by Thesis

    Science.gov (United States)

    Courtis, Barbara

    1974-01-01

    Discusses a student's experience with a research project on the synthesis and reactions of an organo-platinum complex with an organo-Group IV linkage, including the advantages and disadvantages of such a degree by thesis course. (CC)

  14. Comparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation

    Directory of Open Access Journals (Sweden)

    Sanghyun Lee

    2015-01-01

    Full Text Available Purpose. Rapid advanced airway management is important in maternal cardiopulmonary resuscitation (CPR. This study aimed to compare intubation performances among Pentax-AWS (AWS, Glidescope (GVL, and Macintosh laryngoscope (MCL during mechanical chest compression in 15° and 30° left lateral tilt. Methods. In 19 emergency physicians, a prospective randomized crossover study was conducted to examine the three laryngoscopes. Primary outcomes were the intubation time and the success rate for intubation. Results. The median intubation time using AWS was shorter than that of GVL and MCL in both tilt degrees. The time to visualize the glottic view in GVL and AWS was significantly lower than that of MCL (all P<0.05, whereas there was no significant difference between the two video laryngoscopes (in 15° tilt, P=1; in 30° tilt, P=0.71. The progression of tracheal tube using AWS was faster than that of MCL and GVL in both degrees (all P<0.001. Intubations using AWS and GVL showed higher success rate than that of Macintosh laryngoscopes. Conclusions. The AWS could be an appropriate laryngoscope for airway management of pregnant women in tilt CPR considering intubation time and success rate.

  15. Spin Tilts in the Double Pulsar Reveal Off-Center Supernova Kick and Tumble

    CERN Document Server

    Farr, Will M; Lyutikov, Maxim; Kalogera, Vassiliki

    2011-01-01

    The system PSR J0737-3039 is the only binary pulsar known to consist of two radio pulsars (PSR J0737-3039 A and PSR J0737-3039 B). This configuration allows measurements of spin orientation for both pulsars: pulsar A's spin is tilted from the orbital angular momentum by no more than 14 degrees; pulsar B's by 130 degrees. This spin-spin misalignment requires that the origin of most of B's spin is its supernova; the spin could originate from a substantial off-center kick, causing pulsar B to tumble to its misaligned state. Under the typical assumption of an instantaneous kick and using current constraints on the kick magnitude, it must have been displaced from the center of mass of the exploding star by at least 1 km and probably 5--10 km. Regardless of the details of the process that produced pulsar B's current spin, the orientation of the spins in the J0737-3039 system provides a direct, unique constraint on angular momentum production in supernovae.

  16. Interhemispheric Comparison of Dipole Tilt Angle Effects on Latitude of Mid-Altitude Cusp

    Institute of Scientific and Technical Information of China (English)

    GUO Jian-Guang; SHI Jian-Kui; ZHANG Tie-Long; LIU Zhen-Xing

    2008-01-01

    A statistical study of interhemispheric comparison of dipole tilt angle effect on the latitude of the mid-altitude cusp is preformed by a data set of the Cluster cusp crossings over a 5-year period.The result shows that the dipole tilt angle has a clear control of the cusp latitudinal location.When the dipole tilts sunwards,the cusp is shifted poleward.The northern cusp moves 1° ILAT for every 15.4° increase in the dipole tilt angle,while the southern cusp moves 1° ILAT for every 20.8° increase in the dipole tilt angle. This suggests that an interhemispheric difference appears in the dependence of cusp latitudinal location on the dipole tilt angle.

  17. Modulated Electron Bunch with Amplitude Front Tilt in an Undulator

    CERN Document Server

    Geloni, Gianluca; Saldin, Evgeni

    2015-01-01

    In a previous paper we discussed the physics of a microbunched electron beam kicked by the dipole field of a corrector magnet by describing the kinematics of coherent undulator radiation after the kick. We demonstrated that the effect of aberration of light supplies the basis for understanding phenomena like the deflection of coherent undulator radiation by a dipole magnet. We illustrated this fact by examining the operation of an XFEL under the steady state assumption, that is a harmonic time dependence. We argued that in this particular case the microbunch front tilt has no objective meaning; in other words, there is no experiment that can discriminate whether an electron beam is endowed with a microbunch front tilt of not. In this paper we extend our considerations to time-dependent phenomena related with a finite electron bunch duration, or SASE mode of operation. We focus our attention on the spatiotemporal distortions of an X-ray pulse. Spatiotemporal coupling arises naturally in coherent undulator radi...

  18. Evaluation of Anterior Segment's Structures in Tilted Disc Syndrome

    Science.gov (United States)

    Ozsoy, Ercan; Demirel, Ersin Ersan; Cumurcu, Tongabay

    2016-01-01

    Purpose. To evaluate anterior segment's structures by Pentacam in patients with tilted disc syndrome (TDS). Methods. Group 1 included forty-six eyes of forty-six patients who have the TDS. Group 2 including forty-six eyes of forty-six cases was the control group which was equal to the study group in age, gender, and refraction. A complete ophthalmic examination was performed in both groups. All cases were evaluated by Pentacam. The axial length (AL) of eyes was measured by ultrasound. Quantitative data obtained from these measurements were compared between two groups. Results. There was no statistically significant difference for age, gender, axial length, and spherical equivalent measurements between two groups (p = 0.625, p = 0.830, p = 0.234, and p = 0.850). There was a statistically significant difference for central corneal thickness (CCT), corneal volume (CV), anterior chamber angle (ACA), and pupil size measurements between two groups (p = 0.001, p = 0.0001, p = 0.003, and p = 0.001). Also, there was no statistically significant difference for anterior chamber depth (ACD), anterior chamber volume (ACV), and lens thickness (LT) measurements between two groups (p = 0.130, p = 0.910, and p = 0.057). Conclusion. We determined that CCT was thinner, CV was less, and ACA was narrower in patients with TDS. There are some changes in the anterior segment of the eyes with tilted disc. PMID:27648303

  19. Seismometer Detection of Dust Devil Vortices by Ground Tilt

    CERN Document Server

    Lorenz, Ralph D; Murdoch, Naomi; Lognonné, Philippe; Kawamura, Taichi; Mimoun, David; Banerdt, W Bruce

    2015-01-01

    We report seismic signals on a desert playa caused by convective vortices and dust devils. The long-period (10-100s) signatures, with tilts of ~10$^{-7}$ radians, are correlated with the presence of vortices, detected with nearby sensors as sharp temporary pressure drops (0.2-1 mbar) and solar obscuration by dust. We show that the shape and amplitude of the signals, manifesting primarily as horizontal accelerations, can be modeled approximately with a simple quasi-static point-load model of the negative pressure field associated with the vortices acting on the ground as an elastic half space. We suggest the load imposed by a dust devil of diameter D and core pressure {\\Delta}Po is ~({\\pi}/2){\\Delta}PoD$^2$, or for a typical terrestrial devil of 5 m diameter and 2 mbar, about the weight of a small car. The tilt depends on the inverse square of distance, and on the elastic properties of the ground, and the large signals we observe are in part due to the relatively soft playa sediment and the shallow installatio...

  20. Fourier optics analysis of grating sensors with tilt errors.

    Science.gov (United States)

    Ferhanoglu, Onur; Toy, M Fatih; Urey, Hakan

    2011-06-15

    Dynamic diffraction gratings can be microfabricated with precision and offer extremely sensitive displacement measurements and light intensity modulation. The effect of pure translation of the moving part of the grating on diffracted order intensities is well known. This study focuses on the parameters that limit the intensity and the contrast of the interference. The effects of grating duty cycle, mirror reflectivities, sensor tilt and detector size are investigated using Fourier optics theory and Gaussian beam optics. Analytical findings reveal that fringe visibility becomes <0.3 when the optical path variation exceeds half the wavelength within the grating interferometer. The fringe visibility can be compensated by monitoring the interfering portion of the diffracted order light only through detector size reduction in the expense of optical power. Experiments were conducted with a grating interferometer that resulted in an eightfold increase in fringe visibility with reduced detector size, which is in agreement with theory. Findings show that diffraction grating readout principle is not limited to translating sensors but also can be used for sensors with tilt or other deflection modes.

  1. On the tilting of protostellar disks by resonant tidal effects

    CERN Document Server

    Lubow, S H

    2000-01-01

    We consider the dynamics of a protostellar disk surrounding a star in acircular-orbit binary system. Our aim is to determine whether, if the disk isinitially tilted with respect to the plane of the binary orbit, the inclinationof the system will increase or decrease with time. The problem is formulated inthe binary frame in which the tidal potential of the companion star is static.We consider a steady, flat disk that is aligned with the binary plane andinvestigate its linear stability with respect to tilting or warpingperturbations. The dynamics is controlled by the competing effects of the m=0and m=2 azimuthal Fourier components of the tidal potential. In the presence ofdissipation, the m=0 component causes alignment of the system, while the m=2component has the opposite tendency. We find that disks that are sufficientlylarge, in particular those that extend to their tidal truncation radii, aregenerally stable and will therefore tend to alignment with the binary plane ona time-scale comparable to that found ...

  2. Effective ellipsoidal models for wavefield extrapolation in tilted orthorhombic media

    KAUST Repository

    Waheed, Umair Bin

    2016-04-22

    Wavefield computations using the ellipsoidally anisotropic extrapolation operator offer significant cost reduction compared to that for the orthorhombic case, especially when the symmetry planes are tilted and/or rotated. However, ellipsoidal anisotropy does not provide accurate wavefield representation or imaging for media of orthorhombic symmetry. Therefore, we propose the use of ‘effective ellipsoidally anisotropic’ models that correctly capture the kinematic behaviour of wavefields for tilted orthorhombic (TOR) media. We compute effective velocities for the ellipsoidally anisotropic medium using kinematic high-frequency representation of the TOR wavefield, obtained by solving the TOR eikonal equation. The effective model allows us to use the cheaper ellipsoidally anisotropic wave extrapolation operators. Although the effective models are obtained by kinematic matching using high-frequency asymptotic, the resulting wavefield contains most of the critical wavefield components, including frequency dependency and caustics, if present, with reasonable accuracy. The proposed methodology offers a much better cost versus accuracy trade-off for wavefield computations in TOR media, particularly for media of low to moderate anisotropic strength. Furthermore, the computed wavefield solution is free from shear-wave artefacts as opposed to the conventional finite-difference based TOR wave extrapolation scheme. We demonstrate applicability and usefulness of our formulation through numerical tests on synthetic TOR models. © 2016 Institute of Geophysics of the ASCR, v.v.i

  3. An efficient wave extrapolation method for anisotropic media with tilt

    KAUST Repository

    Waheed, Umair bin

    2015-03-23

    Wavefield extrapolation operators for elliptically anisotropic media offer significant cost reduction compared with that for the transversely isotropic case, particularly when the axis of symmetry exhibits tilt (from the vertical). However, elliptical anisotropy does not provide accurate wavefield representation or imaging for transversely isotropic media. Therefore, we propose effective elliptically anisotropic models that correctly capture the kinematic behaviour of wavefields for transversely isotropic media. Specifically, we compute source-dependent effective velocities for the elliptic medium using kinematic high-frequency representation of the transversely isotropic wavefield. The effective model allows us to use cheaper elliptic wave extrapolation operators. Despite the fact that the effective models are obtained by matching kinematics using high-frequency asymptotic, the resulting wavefield contains most of the critical wavefield components, including frequency dependency and caustics, if present, with reasonable accuracy. The methodology developed here offers a much better cost versus accuracy trade-off for wavefield computations in transversely isotropic media, particularly for media of low to moderate complexity. In addition, the wavefield solution is free from shear-wave artefacts as opposed to the conventional finite-difference-based transversely isotropic wave extrapolation scheme. We demonstrate these assertions through numerical tests on synthetic tilted transversely isotropic models.

  4. On the dynamics of tilted black hole-torus systems

    CERN Document Server

    Mewes, Vassilios; Font, José A; Montero, Pedro J; Stergioulas, Nikolaos

    2016-01-01

    We present results from three-dimensional, numerical relativity simulations of a tilted black hole-thick accretion disc system. The simulations are analysed using tracer particles in the disc which are advected with the flow. Such tracers, which we employ in these new simulations for the first time, provide a powerful means to analyse in detail the complex dynamics of tilted black hole-torus systems. We show how its use helps to gain insight in the overall dynamics of the system, discussing the origin of the observed black hole precession and the development of a global non-axisymmetric $m=1$ mode in the disc. Our three-dimensional simulations show the presence of quasi-periodic oscillations (QPOs) in the instantaneous accretion rate, with frequencies in a range compatible with those observed in low mass X-ray binaries with either a black hole or a neutron star component. The frequency ratio of the dominant low frequency peak and the first overtone is $o_1/f \\sim 1.9$, a frequency ratio not attainable when mo...

  5. A tilted interference filter in a converging beam

    CERN Document Server

    Löfdahl, Mats G; Kiselman, Dan

    2011-01-01

    Context. Narrow-band interference filters can be tuned toward shorter wavelengths by tilting them from the perpendicular to the optical axis. This can be used as a cheap alternative to real tunable filters, such as Fabry-P\\'erot interferometers and Lyot filters. At the Swedish 1-m Solar Telescope, such a setup is used to scan through the blue wing of the Ca II H line. Because the filter is mounted in a converging beam, the incident angle varies over the pupil, which causes a variation of the transmission over the pupil, different for each wavelength within the passband. This causes broadening of the filter transmission profile and degradation of the image quality. Aims. We want to characterize the properties of our filter, at normal incidence as well as at different tilt angles. Knowing the broadened profile is important for the interpretation of the solar images. Compensating the images for the degrading effects will improve the resolution and remove one source of image contrast degradation. In particular, w...

  6. Dynamic UCLA for single tilted implant in an aesthetic region.

    Science.gov (United States)

    Goiato, Marcelo Coelho; Sônego, Mariana Vilela; da Silva, Emily Vivianne Freitas; de Carvalho Dekon, Stefan Fiuza; de Medeiros, Rodrigo Antonio; Carvalho, Karina Helga Turcio de; Dos Santos, Daniela Micheline

    2015-01-01

    The aim of this paper was to present a rehabilitation of a patient with a dynamic universal castable long abutment (UCLA) for a single tilted implant in the anterior maxillary area. A 57-year-old male patient attended the dentistry college clinic complaining of a vertical fracture of a residual root of the dental element 22. The tooth extraction was indicated for the implant installation. Due to the socket buccal wall thickness, the implant was installed with an inclination to the palate. It was done in a two-stage surgical protocol, and an external hexagon implant (3.75×11.5mm) was placed. After a six-month healing period to correct the implant position, a dynamic UCLA was set in place, rectifying the implant emergence profile at 20°. The ceramic structure fitting was performed and, after the patient's consent, the prosthesis was finalized and installed. After a follow-up period of twenty months, no complications were observed. The installation of tilted implants with a dynamic UCLA may be a viable option, faster and less invasive than bone grafts. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Single- and dual-wavelength switchable erbium-doped fiber ring laser based on intracavity polarization selective tilted fiber gratings.

    Science.gov (United States)

    Mou, Chengbo; Saffari, Pouneh; Fu, Hongyan; Zhou, Kaiming; Zhang, Lin; Bennion, Ian

    2009-06-20

    We propose and demonstrate a single- and dual-wavelength switchable erbium-doped fiber laser (EDFL) by utilizing intracavity polarization selective filters based on tilted fiber gratings (TFGs). In the cavity, one 45 degrees TFG functions as an in-fiber polarizer and the other 77 degrees TFG is used as a fiber polarization dependent loss (PDL) filter. The combined polarization effect from these two TFGs enables the laser to switch between the single- and the dual-wavelength operation with a single-polarization state at room temperature. The laser output at each wavelength shows an optical signal-to-noise ratio (OSNR) of >60 dB, a side mode suppression ratio (SMSR) of >50 dB, and a polarization extinction ratio of approximately 35 dB. The proposed EDFL can give stable output under laboratory conditions.

  8. Spontaneous tilting after placement of the gunther-tulip inferior vena caval filter: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Tae Seok; Cha, In Ho; Seol, Hae Young; Park, Cheol Min [Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2006-10-15

    Tilting of a deployed filter in the inferior vena cava (IVC) is a particular kind of periprocedural complication and this can reduce the filter's clot-trapping ability and increase the occlusion of the IVC at a later period. The authors report here on a case of spontaneous tilting of an inferior vena caval filter that was associated with thrombosis in the IVC within 2 weeks of the initially successful placement of the filter without tilting.

  9. Measurement of the Floor Tilt in Experimental Determination of the Gravitational Constant

    Institute of Scientific and Technical Information of China (English)

    吴书朝; 黄玉; 范淑华; 罗俊

    2003-01-01

    A prototype of a device with an impact structure for measuring the floor tilt has been built in our laboratory.The mechanical construction and the capacitive transducer of the device are introduced. Experimental results indicate that the floor tilt is about 16μrad in our cavity laboratory, and the uncertainty AG/G caused by such tilt is less than 0.54 parts per million (ppm), so the floor tilt can be reasonably neglected in the experimental determination of the gravitational constant G with the total uncertainty of about 10ppm.

  10. Phase shifting interferometry from two normalized interferograms with random tilt phase-shift.

    Science.gov (United States)

    Liu, Fengwei; Wu, Yongqian; Wu, Fan

    2015-07-27

    We propose a novel phase shifting interferometry from two normalized interferograms with random tilt phase-shift. The determination of tilt phase-shift is performed by extracting the tilted phase-shift plane from the phase difference of two normalized interferograms, and with the calculated tilt phase-shift value the phase distribution can be retrieved from the two normalized frames. By analyzing the distribution of phase difference and utilizing special points fitting method, the tilted phase-shift plane is extracted in three different cases, which relate to different magnitudes of tilts. Proposed method has been applied to simulations and experiments successfully and the satisfactory results manifest that proposed method is of high accuracy and high speed compared with the three step iterative method. Additionally, both open and closed fringe can be analyzed with proposed method. What's more, it cannot only eliminate the small tilt-shift error caused by slight vibration in phase-shifting interferometry, but also detect the large tilt phase-shift in phase-tilting interferometry. Thus, it will relaxes the requirements on the accuracy of phase shifter, and the costly phase shifter may even be useless by applying proposed method in high amplitude vibrated circumstance to achieve high-precision analysis.

  11. ALICE Zero Degree Calorimeter

    CERN Multimedia

    De Marco, N

    2013-01-01

    Two identical sets of calorimeters are located on both sides with respect to the beam Interaction Point (IP), 112.5 m away from it. Each set of detectors consists of a neutron (ZN) and a proton (ZP) Zero Degree Calorimeter (ZDC), positioned on remotely controlled platforms. The ZN is placed at zero degree with respect to the LHC beam axis, between the two beam pipes, while the ZP is positioned externally to the outgoing beam pipe. The spectator protons are separated from the ion beams by means of the dipole magnet D1.

  12. Physics to a degree

    CERN Document Server

    Thomas, EG

    2014-01-01

    Physics to a Degree provides an extensive collection of problems suitable for self-study or tutorial and group work at the level of an undergraduate physics course. This novel set of exercises draws together the core elements of an undergraduate physics degree and provides students with the problem solving skills needed for general physics' examinations and for real-life situations encountered by the professional physicist. Topics include force, momentum, gravitation, Bernoulli's Theorem, magnetic fields, blackbody radiation, relativistic travel, mechanics near the speed of light, radioactive

  13. Registered Nurse (Associate Degree).

    Science.gov (United States)

    Ohio State Univ., Columbus. Center on Education and Training for Employment.

    This document, which is designed for use in developing a tech prep competency profile for the occupation of registered nurse (with an associate degree), lists technical competencies and competency builders for 19 units pertinent to the health technologies cluster in general and 5 units specific to the occupation of registered nurse. The following…

  14. One Degree of Separation

    Science.gov (United States)

    Johnson, Jean

    2012-01-01

    A 2011 survey of young adults conducted by Public Agenda found that a cluster of obstacles have prevented many of them from competing college. The author describes the opportunity, college awareness, and funding gaps that put a postsecondary degree out of the reach of so many young people. For example, just 3 in 10 non-college-completers are aware…

  15. Analysis of influencing factors of compliance of nurse doing head up behaviors based on theory of planned behavior%基于计划行为理论的ICU护士实施床头抬高行为依从性影响因素分析

    Institute of Scientific and Technical Information of China (English)

    程蕾; 罗霞娟

    2015-01-01

    Objective:To analyze the compliance of ICU nurses carrying out head up behaviors for patients with VAP by using the theory of planned behaviors,so as to provide evidences for improving nurses’behavior com-pliance thus to preventventilator associated pneumonia.Methods:Questionnaire was designed based on the the-ory of planned behavior,and it was used to survey the 35 ICU nurses in a third grade A hospital in Guangzhou. The regression was established to analyze the influencing factors of nurses carrying out bed head up.Results:It showed that the behavior attitude,subjective norms and perceived behavioral control were positive correlation with nurses carrying out bed head up(P <0.05).Conclusion:Subjective norms and behavior attitudes were the main factors affecting nurses carrying out bed head up.For the related factors,hospital and department can ana-lyze and define the reasons of poor compliance of nurses and make a targeted work program based on the theory of planned behaviors.%[目的]应用计划行为理论对重症监护室护士针对使用呼吸机的病人实施床头抬高的行为依从性影响因素进行分析,为提高护士行为依从性从而预防呼吸机相关性肺炎提供理论依据。[方法]依据计划行为理论自设问卷,对广州某三级甲等医院重症监护室35名护士进行调查,建立回归方程分析护士实施床头抬高行为的影响因素。[结果]行为态度、主观规范和知觉行为控制与护士床头抬高的实施呈正相关(P <0.05)。[结论]行为态度、主观规范和行为态度是影响护士执行床头抬高的主要因素。医院及科室可依据计划行为理论为指导,分析并明确护士依从性差的原因,制订有针对性的工作计划。

  16. The effects of gantry tilt on breast dose and image noise in cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Hoppe, Michael E.; Gandhi, Diksha; Schmidt, Taly Gilat [Department of Biomedical Engineering, Marquette University, Milwaukee, Wisconsin 53233 (United States); Stevens, Grant M. [GE Healthcare, Waukesha, Wisconsin 53188 (United States); Foley, W. Dennis [Department of Radiology, Medical College of Wisconsin, Froedtert Memorial Lutheran Hospital, Milwaukee, Wisconsin 53226 (United States)

    2013-12-15

    Purpose: This study investigated the effects of tilted-gantry acquisition on image noise and glandular breast dose in females during cardiac computed tomography (CT) scans. Reducing the dose to glandular breast tissue is important due to its high radiosensitivity and limited diagnostic significance in cardiac CT scans.Methods: Tilted-gantry acquisition was investigated through computer simulations and experimental measurements. Upon IRB approval, eight voxelized phantoms were constructed from previously acquired cardiac CT datasets. Monte Carlo simulations quantified the dose deposited in glandular breast tissue over a range of tilt angles. The effects of tilted-gantry acquisition on breast dose were measured on a clinical CT scanner (CT750HD, GE Healthcare) using an anthropomorphic phantom with MOSFET dosimeters in the breast regions. In both simulations and experiments, scans were performed at gantry tilt angles of 0°–30°, in 5° increments. The percent change in breast dose was calculated relative to the nontilted scan for all tilt angles. The percent change in noise standard deviation due to gantry tilt was calculated in all reconstructed simulated and experimental images.Results: Tilting the gantry reduced the breast dose in all simulated and experimental phantoms, with generally greater dose reduction at increased gantry tilts. For example, at 30° gantry tilt, the dosimeters located in the superior, middle, and inferior breast regions measured dose reductions of 74%, 61%, and 9%, respectively. The simulations estimated 0%–30% total breast dose reduction across the eight phantoms and range of tilt angles. However, tilted-gantry acquisition also increased the noise standard deviation in the simulated phantoms by 2%–50% due to increased pathlength through the iodine-filled heart. The experimental phantom, which did not contain iodine in the blood, demonstrated decreased breast dose and decreased noise at all gantry tilt angles.Conclusions: Tilting the

  17. QtUCP-A program for determining unit-cell parameters in electron diffraction experiments using double-tilt and rotation-tilt holders

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Hongsheng [Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Urumqi 830011 (China); Institute of Semiconductors, Chinese Academy of Sciences, P.O. Box 912, Beijing 100083 (China); Graduate School of Chinese Academy of Sciences, Beijing 100049 (China)], E-mail: zhaohscas@yahoo.com.cn; Wu Deqi [Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Urumqi 830011 (China); Institute of Semiconductors, Chinese Academy of Sciences, P.O. Box 912, Beijing 100083 (China); Graduate School of Chinese Academy of Sciences, Beijing 100049 (China); Yao Jincheng; Chang Aimin [Institute of Semiconductors, Chinese Academy of Sciences, P.O. Box 912, Beijing 100083 (China)

    2008-11-15

    A computer program, QtUCP, has been developed based on several well-established algorithms using GCC 4.0 and Qt 4.0 (Open Source Edition) under Debian GNU/Linux 4.0r0. It can determine the unit-cell parameters from an electron diffraction tilt series obtained from both double-tilt and rotation-tilt holders. In this approach, two or more primitive cells of the reciprocal lattice are determined from experimental data, in the meantime, the measurement errors of the tilt angles are checked and minimized. Subsequently, the derived primitive cells are converted into the reduced form and then transformed into the reduced direct primitive cell. Finally all the patterns are indexed and the least-squares refinement is employed to obtain the optimized results of the lattice parameters. Finally, two examples are given to show the application of the program, one is based on the experiment, the other is from the simulation.

  18. QtUCP-a program for determining unit-cell parameters in electron diffraction experiments using double-tilt and rotation-tilt holders.

    Science.gov (United States)

    Zhao, Hongsheng; Wu, Deqi; Yao, Jincheng; Chang, Aimin

    2008-11-01

    A computer program, QtUCP, has been developed based on several well-established algorithms using GCC 4.0 and Qt 4.0 (Open Source Edition) under Debian GNU/Linux 4.0r0. It can determine the unit-cell parameters from an electron diffraction tilt series obtained from both double-tilt and rotation-tilt holders. In this approach, two or more primitive cells of the reciprocal lattice are determined from experimental data, in the meantime, the measurement errors of the tilt angles are checked and minimized. Subsequently, the derived primitive cells are converted into the reduced form and then transformed into the reduced direct primitive cell. Finally all the patterns are indexed and the least-squares refinement is employed to obtain the optimized results of the lattice parameters. Finally, two examples are given to show the application of the program, one is based on the experiment, the other is from the simulation.

  19. A tilted plane as a gravitational field model

    Science.gov (United States)

    Hale, D. P.

    1980-09-01

    Gravitational models have been widely used to study the effects of fields on particle motion. The advantages of such models are: (1) They are often easier or cheaper to construct and use than the system which they represent. (2) Particle motion is readily seen and may be photographed. (3) Events lasting for a fraction of a microsecond as, for example, with electrons moving in electrostatic fields, may be demonstrated in models as events which take a few seconds. The article describes the use of a tilted plane as a two-dimensional, uniform gravitational field. It has been used successfully as a sixth-form physics experiment to demonstrate the motion of projectiles fairly close to the Earth over a limited range. Thus it shows the motion of artillery shells (ignoring air resistance) but not of artificial satellites or long-range rockets, for which a simple uniform field model is not valid.

  20. Learning from history: Adaptive calibration of 'tilting spine' fiber positioners

    CERN Document Server

    Gilbert, James

    2015-01-01

    This paper discusses a new approach for determining the calibration parameters of independently-actuated optical fibers in multi-object astronomical fiber positioning systems. This work comes from the development of a new type of piezoelectric motor intended to enhance the 'tilting spine' fiber positioning technology originally created by the Australian Astronomical Observatory. Testing has shown that the motor's performance can vary depending on the fiber's location within its accessible field, meaning that an individual fiber is difficult calibrate with a one-time routine. Better performance has resulted from constantly updating calibration parameters based on the observed movements of the fiber during normal closed-loop positioning. Over time, location-specific historical data is amassed that can be used to better predict the results of a future fiber movement. This is similar to a technique previously proposed by the Australian Astronomical Observatory, but with the addition of location-specific learning....

  1. The Lyth Bound of Inflation with a Tilt

    CERN Document Server

    Garcia-Bellido, Juan; Scalisi, Marco; Zavala, Ivonne

    2014-01-01

    We provide strong evidence for universality of the inflationary field range: given an accurate measurement of $(n_s,r)$, one can infer $\\Delta \\phi$ in a model-independent way in the sub-Planckian regime for a range of universality classes of inflationary models. Both the tensor-to-scalar ratio as well as the spectral tilt are essential for the field range. Given the Planck constraints on $n_s$, the Lyth bound is strengthened by two orders of magnitude: whereas the original bound gives a sub-Planckian field range for $r \\lesssim 2 \\cdot 10^{-3}$, we find that $n=0.96$ brings this down to $r \\lesssim 2 \\cdot 10^{-5}$.

  2. Rain Sensor with Stacked Light Waveguide Having Tilted Air Gap

    Directory of Open Access Journals (Sweden)

    Kyoo Nam Choi

    2014-01-01

    Full Text Available Vehicle sensor to detect rain drop on and above waveguide utilizing light deflection and scattering was realized, keeping wide sensing coverage and sensitivity to detect mist accumulation. Proposed sensor structure under stacked light wave guide consisted of light blocking fixture surrounding photodetector and adjacent light source. Tilted air gap between stacked light waveguide and light blocking fixture played major role to increase sensitivity and to enhance linearity. This sensor structure eliminated complex collimating optics, while keeping wide sensing coverage using simple geometry. Detection algorithm based on time-to-intensity transformation process was used to convert raining intensity into countable raining process. Experimental result inside simulated rain chamber showed distinct different response between light rain and normal rain. Application as automobile rain sensor is expected.

  3. Bound Chains of Tilted Dipoles in Layered Systems

    DEFF Research Database (Denmark)

    G. Volosniev, A.; R. Armstrong, J.; V. Fedorov, D.;

    2012-01-01

    is fascinating. Here we concentrate on few-body states in a multilayered setup. We exploit the geometry of the interlayer potential to calculate the two- and three-body chains with one molecule in each layer. The focus is on dipoles that are aligned at some angle with respect to the layer planes by means...... of an external eletric field. The binding energy and the spatial structure of the bound states are studied in several different ways using analytical approaches. The results are compared to stochastic variational calculations and very good agreement is found. We conclude that approximations based on harmonic...... oscillator potentials are accurate even for tilted dipoles when the geometry of the potential landscape is taken into account....

  4. Flow tilt angles near forest edges - Part 2: Lidar anemometry

    DEFF Research Database (Denmark)

    Dellwik, Ebba; Mann, Jakob; Bingöl, Ferhat

    2010-01-01

    ) a fetch-limited beech forest site taken at 48–175 m a.g.l. (above ground level), (2) a reference site in flat agricultural terrain and (3) a second reference site in complex terrain are presented. The method to derive flow tilt angles and mean vertical velocities from lidar has several advantages compared...... vertical velocity, whereas the error due to flow inhomogeneity on the horizontal mean wind speed is independent of the lidar beam angle. For the presented measurements over forest, it is evaluated that the systematic error due to the inhomogeneity of the flow is less than 0.2°. The results of the vertical...... conical scans were promising, and yielded positive flow angles for a sector where the forest is fetch-limited. However, more data and analysis are needed for a complete evaluation of the lidar technique....

  5. Supramolecular tilt chirality in crystals of steroids and alkaloids.

    Science.gov (United States)

    Hisaki, Ichiro; Tohnai, Norimitsu; Miyata, Mikiji

    2008-03-01

    The concept of supramolecular chirality has assumed increasing importance in association with the development of supramolecular chemistry over the last two decades. In chiral crystals, 2 1 helical molecular assemblies are frequently observed as key motifs. Helical handedness of the 2 1 assemblies, however, has not been determined from the mathematical or crystallographical viewpoints. In this context, we have proposed two new concepts, three-axial chirality and tilt chirality. On the basis of the concepts, we describe supramolecular chirality and determine the handedness of 2 1 assemblies that are composed of relatively complicated molecules with multiple stereogenic centers such as brucine, bile acids, and cinchona alkaloids as well as those of simple molecules.

  6. Three-dimensional deconvolution microfluidic microscopy using a tilted channel

    Science.gov (United States)

    Pégard, Nicolas C.; Fleischer, Jason W.

    2013-04-01

    We have developed a microfluidic device that enables the computation of three-dimensional (3-D) images of flowing samples. Using a microfluidic channel that is tilted along the optical axis, we record several progressively defocused images of the flowing sample as it passes across the focal plane. The resulting focal stack is then deconvolved to generate 3-D images. Experimental results on flowing yeast cells reveal both volume and surface profile information. The microfluidic channel eliminates the need for a precise translation stage to control defocusing and enables high sample throughput in an insulated, nontoxic, liquid environment. The experimental device can be implemented in all existing microscopes as a modified slide stage and is ideally suited for 3-D profiling in flow cytometers.

  7. Strain Accommodation By Facile WO6 Octahedral Distortion and Tilting During WO3 Heteroepitaxy on SrTiO3(001)

    Energy Technology Data Exchange (ETDEWEB)

    Du, Yingge; Gu, Meng; Varga, Tamas; Wang, Chong M.; Bowden, Mark E.; Chambers, Scott A.

    2014-08-27

    In this paper, we show that compared to other BO6 octahedra in ABO3 structured perovskite oxides, the WO6 octahedra in tungsten trioxide (WO3) can withstand a much larger degree of distortion and tilting to accommodate interfacial strain, which in turn strongly impact the nucleation, structure, and defect formation during the epitaxial growth of WO3 on SrTiO3(001). A meta-stable tetragonal phase can be stabilized by epitaxy and a thickness dependent phase transition (tetragonal to monoclinic) is observed. In contrast to misfit dislocations to accommodate the interfacial stain, the facial WO6 octahedral distortion and tilting give rise to three types of planar defects that affect more than 15 monolayers from the interface. These atomically resolved, unusual interfacial defects may significantly alter the electronic, electrochromic, and mechanical properties of the epitaxial films.

  8. Optimum Tilt Angle for Photovoltaic Solar Panels in Zomba District, Malawi

    Directory of Open Access Journals (Sweden)

    B. Kamanga

    2014-01-01

    Full Text Available A study to determine the optimum tilt angle for installing photovoltaic solar panels in Zomba district, Malawi, has been conducted. The study determined the optimum monthly tilt angles of PV solar panels and the seasonal adjustments needed for the panels in order to collect maximum solar radiation throughout the year. In this study, global solar radiation (GSR on four tilted surfaces was measured. The north-facing surfaces were titled at angles of 0°, 15°, 20°, and 25°. The GSR data was used to determine the daily and monthly optimum tilt angles for the PV panels. The optimum tilt angles were found to be 0° or 25° depending on the time of the year. From October to February, the optimum tilt angle has been determined to be 0° and, from March to September, the optimum tilt angle is observed to be 25°. There are only two seasonal adjustments that are needed for PV solar panels in Zomba district and these should be carried out at the end of February and at the end of September. For fixed solar panels with no seasonal adjustments, the optimum tilt angle for the PV solar panels that are northfacing has been determined to be 25°.

  9. On the simplifications for the thermal modeling of tilting-pad journal bearings under thermoelastohydrodynamic regime

    DEFF Research Database (Denmark)

    Cerda Varela, Alejandro Javier; Fillon, Michel; Santos, Ilmar

    2012-01-01

    The relevance of calculating accurately the oil film temperature build up when modeling tilting-pad journal bearings is well established within the literature on the subject. This work studies the feasibility of using a thermal model for the tilting-pad journal bearing which includes a simplified...

  10. Re-examining Sunspot Tilt Angle to Include Anti-Hale Statistics

    CERN Document Server

    McClintock, Bruce H; Li, Jing

    2014-01-01

    Sunspot groups and bipolar magnetic regions (BMRs) serve as an observational diagnostic of the solar cycle. We use Debrecen Photohelographic Data (DPD) from 1974-2014 that determined sunspot tilt angles from daily white light observations, and data provided by Li & Ulrich that determined sunspot magnetic tilt angle using Mount Wilson magnetograms from 1974-2012. The magnetograms allowed for BMR tilt angles that were anti-Hale in configuration, so tilt values ranged from 0 to 360{\\deg} rather than the more common $\\pm$ 90{\\deg}. We explore the visual representation of magnetic tilt angles on a traditional butterfly diagram by plotting the mean area-weighted latitude of umbral activity in each bipolar sunspot group, including tilt information. The large scatter of tilt angles over the course of a single cycle and hemisphere prevents Joy's law from being visually identified in the tilt-butterfly diagram without further binning. The average latitude of anti-Hale regions does not differ from the average latitu...

  11. Patients with severe acquired brain injury show increased arousal in tilt-table training

    DEFF Research Database (Denmark)

    Riberholt, Christian G; Thorlund, Jonas Bloch; Mehlsen, Jesper;

    2013-01-01

    Patients with severe acquired brain injury (ABI) are often mobilised using a tilt-table. Complications such as orthostatic intolerance have been reported. The primary objective of this study was to investigate if using a tilt-table was feasible for mobilising patients with severe ABI admitted...

  12. Effect of compression paddle tilt correction on volumetric breast density estimation.

    Science.gov (United States)

    Kallenberg, Michiel G J; van Gils, Carla H; Lokate, Mariëtte; den Heeten, Gerard J; Karssemeijer, Nico

    2012-08-21

    For the acquisition of a mammogram, a breast is compressed between a compression paddle and a support table. When compression is applied with a flexible compression paddle, the upper plate may be tilted, which results in variation in breast thickness from the chest wall to the breast margin. Paddle tilt has been recognized as a major problem in volumetric breast density estimation methods. In previous work, we developed a fully automatic method to correct the image for the effect of compression paddle tilt. In this study, we investigated in three experiments the effect of paddle tilt and its correction on volumetric breast density estimation. Results showed that paddle tilt considerably affected accuracy of volumetric breast density estimation, but that effect could be reduced by tilt correction. By applying tilt correction, a significant increase in correspondence between mammographic density estimates and measurements on MRI was established. We argue that in volumetric breast density estimation, tilt correction is both feasible and essential when mammographic images are acquired with a flexible compression paddle.

  13. SYSTEMATIC ERROR REDUCTION: NON-TILTED REFERENCE BEAM METHOD FOR LONG TRACE PROFILER.

    Energy Technology Data Exchange (ETDEWEB)

    QIAN,S.; QIAN, K.; HONG, Y.; SENG, L.; HO, T.; TAKACS, P.

    2007-08-25

    Systematic error in the Long Trace Profiler (LTP) has become the major error source as measurement accuracy enters the nanoradian and nanometer regime. Great efforts have been made to reduce the systematic error at a number of synchrotron radiation laboratories around the world. Generally, the LTP reference beam has to be tilted away from the optical axis in order to avoid fringe overlap between the sample and reference beams. However, a tilted reference beam will result in considerable systematic error due to optical system imperfections, which is difficult to correct. Six methods of implementing a non-tilted reference beam in the LTP are introduced: (1) application of an external precision angle device to measure and remove slide pitch error without a reference beam, (2) independent slide pitch test by use of not tilted reference beam, (3) non-tilted reference test combined with tilted sample, (4) penta-prism scanning mode without a reference beam correction, (5) non-tilted reference using a second optical head, and (6) alternate switching of data acquisition between the sample and reference beams. With a non-tilted reference method, the measurement accuracy can be improved significantly. Some measurement results are presented. Systematic error in the sample beam arm is not addressed in this paper and should be treated separately.

  14. Motion sickness and tilts of the inertial force environment: active suspension systems vs. active passengers

    NARCIS (Netherlands)

    Golding, J.F.; Bles, W.; Bos, J.E.; Haynes, T.; Gresty, M.A.

    2003-01-01

    Maneuvering in vehicles exposes occupants to low frequency forces (<1 Hz) which can provoke motion sickness. Hypothesis: Aligning with the tilting inertial resultant (gravity + imposed horizontal acceleration: gravito-inertial force (GIF)) may reduce motion sickness when tilting is either 'active'

  15. Motion sickness and tilts of the inertial force environment: active suspension systems vs. active passengers

    NARCIS (Netherlands)

    Golding, J.F.; Bles, W.; Bos, J.E.; Haynes, T.; Gresty, M.A.

    2003-01-01

    Maneuvering in vehicles exposes occupants to low frequency forces (<1 Hz) which can provoke motion sickness. Hypothesis: Aligning with the tilting inertial resultant (gravity + imposed horizontal acceleration: gravito-inertial force (GIF)) may reduce motion sickness when tilting is either 'active' (

  16. The Application of Normal Stress Reduction Function in Tilt Tests for Different Block Shapes

    Science.gov (United States)

    Kim, Dong Hyun; Gratchev, Ivan; Hein, Maw; Balasubramaniam, Arumugam

    2016-08-01

    This paper focuses on the influence of the shapes of rock cores, which control the sliding or toppling behaviours in tilt tests for the estimation of rock joint roughness coefficients (JRC). When the JRC values are estimated by performing tilt tests, the values are directly proportional to the basic friction of the rock material and the applied normal stress on the sliding planes. Normal stress obviously varies with the shape of the sliding block, and the basic friction angle is also affected by the sample shapes in tilt tests. In this study, the shapes of core blocks are classified into three representative shapes and those are created using plaster. Using the various shaped artificial cores, a set of tilt tests is carried out to identify the shape influences on the normal stress and the basic friction angle in tilt tests. The test results propose a normal stress reduction function to estimate the normal stress for tilt tests according to the sample shapes based on Barton's empirical equation. The proposed normal stress reduction functions are verified by tilt tests using artificial plaster joints and real rock joint sets. The plaster joint sets are well matched and cast in detailed printed moulds using a 3D printing technique. With the application of the functions, the obtained JRC values from the tilt tests using the plaster samples and the natural rock samples are distributed within a reasonable JRC range when compared with the measured values.

  17. Gravito-Inertial Force Resolution in Perception of Synchronized Tilt and Translation

    Science.gov (United States)

    Wood, Scott J.; Holly, Jan; Zhang, Guen-Lu

    2011-01-01

    Natural movements in the sagittal plane involve pitch tilt relative to gravity combined with translation motion. The Gravito-Inertial Force (GIF) resolution hypothesis states that the resultant force on the body is perceptually resolved into tilt and translation consistently with the laws of physics. The purpose of this study was to test this hypothesis for human perception during combined tilt and translation motion. EXPERIMENTAL METHODS: Twelve subjects provided verbal reports during 0.3 Hz motion in the dark with 4 types of tilt and/or translation motion: 1) pitch tilt about an interaural axis at +/-10deg or +/-20deg, 2) fore-aft translation with acceleration equivalent to +/-10deg or +/-20deg, 3) combined "in phase" tilt and translation motion resulting in acceleration equivalent to +/-20deg, and 4) "out of phase" tilt and translation motion that maintained the resultant gravito-inertial force aligned with the longitudinal body axis. The amplitude of perceived pitch tilt and translation at the head were obtained during separate trials. MODELING METHODS: Three-dimensional mathematical modeling was performed to test the GIF-resolution hypothesis using a dynamical model. The model encoded GIF-resolution using the standard vector equation, and used an internal model of motion parameters, including gravity. Differential equations conveyed time-varying predictions. The six motion profiles were tested, resulting in predicted perceived amplitude of tilt and translation for each. RESULTS: The modeling results exhibited the same pattern as the experimental results. Most importantly, both modeling and experimental results showed greater perceived tilt during the "in phase" profile than the "out of phase" profile, and greater perceived tilt during combined "in phase" motion than during pure tilt of the same amplitude. However, the model did not predict as much perceived translation as reported by subjects during pure tilt. CONCLUSION: Human perception is consistent with

  18. A tomographic algorithm to determine tip-tilt information from laser guide stars

    Science.gov (United States)

    Reeves, A. P.; Morris, T. J.; Myers, R. M.; Bharmal, N. A.; Osborn, J.

    2016-06-01

    Laser Guide Stars (LGS) have greatly increased the sky-coverage of Adaptive Optics (AO) systems. Due to the up-link turbulence experienced by LGSs, a Natural Guide Star (NGS) is still required, preventing full sky-coverage. We present a method of obtaining partial tip-tilt information from LGSs alone in multi-LGS tomographic LGS AO systems. The method of LGS up-link tip-tilt determination is derived using a geometric approach, then an alteration to the Learn and Apply algorithm for tomographic AO is made to accommodate up-link tip-tilt. Simulation results are presented, verifying that the technique shows good performance in correcting high altitude tip-tilt, but not that from low altitudes. We suggest that the method is combined with multiple far off-axis tip-tilt NGSs to provide gains in performance and sky-coverage over current tomographic AO systems.

  19. A tomographic algorithm to determine tip-tilt information from laser guide stars

    CERN Document Server

    Reeves, A P; Myers, R M; Bharmal, N A; Osborn, J

    2016-01-01

    Laser Guide Stars (LGS) have greatly increased the sky-coverage of Adaptive Optics (AO) systems. Due to the up-link turbulence experienced by LGSs, a Natural Guide Star (NGS) is still required, preventing full sky-coverage. We present a method of obtaining tip-tilt information from LGSs alone in multi-LGS tomographic LGS AO systems. The method of LGS up-link tip-tilt determination is derived using a geometric approach, then an alteration to the Learn and Apply algorithm for tomographic AO is made to accommodate up-link tip-tilt. Simulation results are presented, verifying that the technique shows good performance in correcting high altitude tip-tilt, but not that from low altitudes. We suggest that the method is combined with far off-axis tip-tilt NGS to provide gains in performance and sky-coverage over current tomographic AO systems.

  20. Tilted seat position for non-ambulant individuals with neurological and neuromuscular impairment: a systematic review.

    Science.gov (United States)

    Michael, S M; Porter, D; Pountney, T E

    2007-12-01

    To determine the effects of tilt-in-space seating on outcomes for people with neurological or neuromuscular impairment who cannot walk. Search through electronic databases (MEDLINE, Embase, CINAHL, AMED). Discussions with researchers who are active in field. Selection criteria included interventional studies that investigated the effects of seat tilt on outcome or observational studies that identified outcomes for those who had used tilt-in-space seating in populations with neurological or neuromuscular impairments. Two reviewers independently selected trials for inclusion, assessed quality and extracted data. Nineteen studies were identified which fulfilled the selection criteria. Seventeen of these were essentially before-after studies investigating the immediate effects of tilting the seating. All studies looked at populations with neurological impairment, and most were on children with cerebral palsy (n=8) or adults with spinal cord injury (n=8). REVIEWER'S CONCLUSION: Posterior tilt can reduce pressures at the interface under the pelvis.

  1. Performance verification of focus variation and confocal microscopes measuring tilted ultra-fine surfaces

    DEFF Research Database (Denmark)

    Quagliotti, Danilo; Baruffi, Federico; Tosello, Guido

    2016-01-01

    The behaviour of two optical instruments, scilicet a laser scanning confocal microscope and a focus-variation microscope, was investigated considering measurements of tilted surfaces. The measured samples were twelve steel artefacts for mould surface finish reference, covering Sa roughness...... parameter in the range (101—103) nm. The 3D surface texture parameters considered were Sa, Sq and Sdq. The small working distance of the confocal microscope objectives influenced the measurement setup, preventing from selecting a high tilting angle. The investigation was carried out comparing measurements...... of flat surfaces (0° tilt) with measurements of 12.5° tilted surfaces. The confocal microscope results showed a high sensitivity to tilting due to the laser beam reflection on the metal surfaces. The focus variation microscope results were more robust with respect to the considered angular variation...

  2. Tilt angle dependence of the modulated interference effects in photo-elastic modulators

    Science.gov (United States)

    Talukder, Md. Abdul Ahad; Geerts, Wilhelmus J.

    2017-05-01

    The effect of the PEM tilt angle and incident polarization on the PEM interference is studied for a single axis photo-elastic modulator. The dc, 1ω , and 2ω components of the detector signal vary periodically as a function of PEM tilt angle. Although it is possible to adjust the PEM tilt angle to minimize the 1ω or 2ω detector signal at small tilt angles, it is not possible to null both of them simultaneously. For the case where no analyzer is used, the ac detector signals can be minimized simultaneously by adjusting the polarization angle of the light incident on the PEM and the PEM tilt angle. Direct observations of the detector signal indicate that the effects of refraction index and thickness variations are opposite consistent with a lower polarizability for compressive strain of the modulator.

  3. Tilt angle dependence of the modulated interference effects in photo-elastic modulators

    Directory of Open Access Journals (Sweden)

    Md. Abdul Ahad Talukder

    2017-05-01

    Full Text Available The effect of the PEM tilt angle and incident polarization on the PEM interference is studied for a single axis photo-elastic modulator. The dc, 1ω, and 2ω components of the detector signal vary periodically as a function of PEM tilt angle. Although it is possible to adjust the PEM tilt angle to minimize the 1ω or 2ω detector signal at small tilt angles, it is not possible to null both of them simultaneously. For the case where no analyzer is used, the ac detector signals can be minimized simultaneously by adjusting the polarization angle of the light incident on the PEM and the PEM tilt angle. Direct observations of the detector signal indicate that the effects of refraction index and thickness variations are opposite consistent with a lower polarizability for compressive strain of the modulator.

  4. Increasing the sensitivity for tilt measurement using a cyclic interferometer with multiple reflections

    Science.gov (United States)

    Pretheesh Kumar, Valiyaparambil Chacko; Joenathan, Charles; Ganesan, Angarai; Somasundram, Umapathy

    2016-08-01

    Measurement of tilt plays an important role in metrological applications and consequently, several methods have been proposed in the recent past. Classical interferometric methods can measure angles with high accuracy but are easily susceptible to external turbulences. We propose to use a cyclic interferometer to measure tilt in which the sensitivity to tilt measurement is double when compared with that of the classical Michelson interferometer. Since the counter propagating beams travel identical paths, the interferometer is insensitive to external vibrations and turbulence and thus can be used under harsh environmental conditions. The novelty in the technique lies in creating multiple reflections in the tilt mirror to enhance the measurement accuracy by the way of increasing the sensitivity. This paper presents the basics of the interferometer and experimental results to quantify the increase in sensitivity. By increasing the number of reflections, it is shown that sensitivity can be further improved to measure tilt angles below 5 μrad.

  5. Investigating Of Proper Photovoltaic Panel Tilt Angle to Be Used As Shading Device inKuwait

    Directory of Open Access Journals (Sweden)

    Hussain Bunyan

    2015-01-01

    Full Text Available Photovoltaic panels can act as power generator as well as external shading devices with proper tilt angle. In this paper we will study the performance of a Silicon Photovoltaic system with different tilt angle arrangement in Kuwait (latitude 30˚ N. In the study the PV system is installed facing south to collectmaximum solar radiation at noon. The angle is varied from 00 to 900 , during full year at the Solstice (the time at which the day and night come into balance and Equinox (the end of the day’s increase or decrease in day night hours periods, to achieve optimum tilt angle, higher in magnitude than 30 0 with competitive output power. The results show that the performance and the output power of the PV system with 50˚ tilt angle, is equivalent to the corresponding values at tilt angle equal to Kuwait latitude (30˚ during the whole year.

  6. Magneto-transport studies of a few hole GaAs double quantum dot in tilted magnetic fields

    Science.gov (United States)

    Studenikin, Sergei; Bogan, Alex; Tracy, Lisa; Gaudreau, Louis; Sachrajda, Andy; Korkusinski, Marek; Reno, John; Hargett, Terry

    Compared to equivalent electron devices, single-hole spins interact weakly with lattice nuclear spins leading to extended quantum coherence times. This makes p-type Quantum Dots (QD) particularly attractive for practical quantum devices such as qubit circuits, quantum repeaters, quantum sensors etc. where long coherence time is required. Another property of holes is the possibility to tune their g-factor as a result of the strong anisotropy of the valance band. Hole g-factors can be conveniently tuned in situ from a large value to almost zero by tilting the magnetic field relative to the 2D hole gas surface normal. In this work we explore high-bias magneto-transport properties of a p-type double quantum dot (DQD) device fabricated from a GaAs/AlGaAs heterostructures using lateral split-gate technology. A charge detection technique is used to monitor number of holes and tune the p-DQD in a single hole regime around (1,1) and (2,0) occupation states where Pauli spin-blockaded transport is expected. Four states are identified in quantizing magnetic fields within the high-bias current stripe - three-fold triplet and a singlet which allows determining effective heavy hole g-factor as a function of the tilt angle from 90 to 0 degrees.

  7. Direct Burial Broadband Seismic Instrumentation that are Rugged and Tilt Tolerant for Polar Environments

    Science.gov (United States)

    Parker, Tim; Winberry, Paul; Huerta, Audrey; Bainbridge, Geoff; Devanney, Peter

    2016-04-01

    The integrated broadband Meridian Posthole and Compact seismic systems have been engineered and tested for extreme polar environments. Ten percent of the Earth's surface is covered in glacial ice and the dynamics of these environments is a strategic concern for all. The development for these systems was driven by researchers needing to densify observations in ice covered regions with difficult and limited logistics. Funding from an NSF MRI award, GEOICE and investment from the vendor enabled researchers to write the specifications for a hybrid family of instruments that can operate at -55C autonomously with very little power, 1 watt for the Meridian Compact system and 1.5 watts for the Meridian 120PH. Tilt tolerance in unstable ice conditions was a concern and these instruments have a range of up to +/-5 degrees. The form factor, extreme temperature tolerance and power load of the instruments has reduced the bulk of a complete station by 1/2 and simplified installation greatly allowing more instruments to be deployed with limited support and a lighter logistical load. These systems are being tested in the Antarctic at SouthPole Station and McMurdo for the second year and the investment has encouraged other instrument and power system vendors to offer polar rated equipment including telemetry for ancillary support.

  8. IMU Application in Measurement of Vehicle Position and Orientation for Controlling a Pan-Tilt Mechanism

    Directory of Open Access Journals (Sweden)

    Hendri Maja Saputra

    2013-07-01

    Full Text Available This paper describes a modeling and designing of inertial sensor using Inertial Measurement Unit (IMU to measure the position and orientation of a vehicle motion. Sensor modeling is used to derive the vehicle attitude models where the sensor is attached while the sensor design is used to obtain the data as the input to control the angles of a pan-tilt mechanism with 2 degrees of freedom. Inertial sensor Phidget Spatial 3/3/3, which is a combination of 3-axis gyroscope, 3-axis accelerometer and 3-axis magnetometer, is used as the research object. Software for reading the sensor was made by using Matlab™. The result shows that the software can be applied to the sensor in the real-time reading process. The sensor readings should consider several things i.e. (a sampling time should not be less than 32 ms and (b deviation ratio between measurement noise (r and process noise (q for the parameters of Kalman filter is 1:5 (i.e. r = 0.08 and q = 0.4.

  9. 偏倾斜模和倾斜模的分次与非分次性质%Graded and Nongraded Properties of Partial Tilting Modules and Tilting Modules

    Institute of Scientific and Technical Information of China (English)

    郑敏; 陈清华

    2009-01-01

    This paper gives the relationships among partial tilting objects(tilting objects)of categories of graded left A-modules of type G,left A-modules,left Ae-modules and A#G-modules,and then proves that for graded partial tilting modules,there exist the Bongartz complements in the category of graded A-modules.

  10. Columnar shifts as symmetry-breaking degrees of freedom in molecular perovskites.

    Science.gov (United States)

    Boström, Hanna L B; Hill, Joshua A; Goodwin, Andrew L

    2016-11-23

    We introduce columnar shifts-collective rigid-body translations-as a structural degree of freedom relevant to the phase behaviour of molecular perovskites ABX3 (X = molecular anion). Like the well-known octahedral tilts of conventional perovskites, shifts also preserve the octahedral coordination geometry of the B-site cation in molecular perovskites, and so are predisposed to influencing the low-energy dynamics and displacive phase transitions of these topical systems. We present a qualitative overview of the interplay between shift activation and crystal symmetry breaking, and introduce a generalised terminology to allow characterisation of simple shift distortions, drawing analogy to the "Glazer notation" for octahedral tilts. We apply our approach to the interpretation of a representative selection of azide and formate perovskite structures, and discuss the implications for functional exploitation of shift degrees of freedom in negative thermal expansion materials and hybrid ferroelectrics.

  11. [The experiment research on solution refractive index sensor based on tilted fiber Bragg grating].

    Science.gov (United States)

    Jiang, Qi; Lü, Dan-Dan; Yu, Ming-Hao; Kang, Li-Min; Ouyang, Jun

    2013-12-01

    The present paper analyzes the sensor's basic principle of the bare tilted fiber Bragg grating (TFBG) and surface plasmon resonance sensor (SPR) that deposited nanoscale gold-coating on the surface of the cladding. We simulated the transmission spectrums and some order cladding mode of TFBG in different concentration solutions by Integration and optical fiber grating software OptiGrating. So by the graphic observation and data analysis, a preliminary conclusion was got that in a certain sensing scope, the cladding modes of TFBG shift slightly to right with the increasing the solution refractive index(SRI),and the relation between resonance peak caused by the coupling of core mode and a certain cladding mode and the SRI was linear. Then the 45 nm thick gold coating was deposited on the surface of the TFBG cladding in a small-scale sputtering chamber KYKY SBC-12, and thermal field scanning electron microscopy presents that the effect of gold-coating was satisfactory to a certain extent in terms of microscopic level. The refractive index(RI) sensing experiments of different concentration solutions of NaCI, MgCI2, CaCI2 were carried out using bare and gold deposited TFBG. The RI sensing characteristics of both bare and gold deposited TFBGs respectively were studied by experiments. Meanwhile, it proved the conclusion that the cladding modes of TFBG drifted to right gradually when the SRI was increasing and the relations between resonance peak caused by the coupling of core mode and a certain cladding mode and the SRI were linear. And by quantitative analysis, we know that SPR sensor with the deposited namoscale gold layer on the surface of cladding enhanced the RI sensitivity dramatically by 2 to 500 nm RIU-1 which is 200 to 300 times larger than that of the bare tilted fiber Bragg grating approximately. The degrees of linear fittings of resonance peak caused by the coupling of core mode and a certain cladding mode and SRI of bare and gold-coating deposited SPR sensor

  12. When Graduate Degrees Prostitute the Educational Process: Degrees Gone Wild

    Science.gov (United States)

    Lumadue, Richard T.

    2006-01-01

    Graduate degrees prostitute the educational process when they are sold to consumers by unaccredited degree/diploma mills as being equivalent to legitimate, bona-fide degrees awarded by accredited graduate schools. This article carefully analyzes the serious problems of bogus degrees and their association with the religious higher education…

  13. Early Poststroke Rehabilitation Using a Robotic Tilt-Table Stepper and Functional Electrical Stimulation

    Directory of Open Access Journals (Sweden)

    Alexey N. Kuznetsov

    2013-01-01

    Full Text Available Background. Stroke frequently leaves survivors with hemiparesis. To prevent persistent deficits, rehabilitation may be more effective if started early. Early training is often limited because of orthostatic reactions. Tilt-table stepping robots and functional electrical stimulation (FES may prevent these reactions. Objective. This controlled convenience sample study compares safety and feasibility of robotic tilt-table training plus FES (ROBO-FES and robotic tilt-table training (ROBO against tilt-table training alone (control. A preliminary assessment of efficacy is performed. Methods. Hemiparetic ischemic stroke survivors (age years, days after stroke were assigned to 30 days of ROBO-FES (, ROBO (, or control ( in addition to conventional physical therapy. Impedance cardiography and transcranial doppler sonography were performed before, during, and after training. Hemiparesis was assessed using the British Medical Research Council (MRC strength scale. Results. No serious adverse events occurred; 8 patients in the tilt-table group prematurely quit the study because of orthostatic reactions. Blood pressure and CBFV dipped % during robot training. In 52% of controls mean arterial pressure decreased by %. ROBO-FES increased leg strength by points, ROBO by more than control (, . CBFV increased in both robotic groups more than in controls (. Conclusions. Robotic tilt-table exercise with or without FES is safe and may be more effective in improving leg strength and cerebral blood flow than tilt table alone.

  14. Sunspot group tilt angles and the strength of the solar cycle

    CERN Document Server

    Dasi-Espuig, Maria; Krivova, Natasha A; Cameron, Robert H; Peñuela, Tania

    2010-01-01

    It is known that the tilt angles of active regions increase with their latitude (Joy's law). It has never been checked before, however, whether the average tilt angles change from one cycle to another. Flux transport models show the importance of tilt angles for the reversal and build up of magnetic flux at the poles which is, in turn, correlated with the strength of the next cycle. Here we analyse time series of tilt angle measurements and look for a possible relationship of the tilt angles with other solar cycle parameters, in order to glean information on the solar dynamo and to estimate their potential for predictions of solar activity. We employ tilt angle data from Mount Wilson and Kodaikanal observatories covering solar cycles 15 to 21. We analyse the latitudinal distribution of the tilt angles (Joy's law), their variation from cycle to cycle and their relationship to other solar cycle parameters, such as the strength, amplitude and length. The two main results are: 1. An anti-correlation between the m...

  15. Evaluation of peripapillary choroidal and retinal nerve fiber layer thickness in eyes with tilted optic disc

    Directory of Open Access Journals (Sweden)

    Muammer Ozcımen

    2014-12-01

    Full Text Available Purpose: This study was performed to evaluate the retinal nerve fiber layer (RNFL and peripapillary choroidal thickness in eyes with tilted optic disc in order to identify characteristic RNFL and peripapillary choroid patterns verified by optical coherence tomography (OCT. Methods: Twenty-nine eyes of 29 patients with tilted optic discs were studied with spectral-domain (SD-OCT and compared with age and sex-matched control subjects in a prospective design. The imaging of RNFL was performed using circular scans of a diameter of 3.4 mm around the optic disc using OCT. For measurements of peripapillary choroidal thickness, the standar d protocol for RNFL assessment was performed. Results: SD-OCT indicated significantly lower superotemporal (p<0.001, superonasal (p=0.001, and global (p=0.005 RNFL thicknesses in the tilted disc group than those of the control group. Peripapillary choroid was significantly thicker at the site of the elevated rim of eyes with tilted disc (p<0.001. Conclusion: This study demonstrated a clinical characterization of the main tilted disc morphologies that may be helpful in differentiating a tilted disc from other altered disc morphologies. Further studies are recommended to study the comparison between glaucoma and tilted disc groups.

  16. Tilted microstrip phased arrays with improved electromagnetic decoupling for ultrahigh-field magnetic resonance imaging.

    Science.gov (United States)

    Pang, Yong; Wu, Bing; Jiang, Xiaohua; Vigneron, Daniel B; Zhang, Xiaoliang

    2014-12-01

    One of the technical challenges in designing a dedicated transceiver radio frequency (RF) array for MR imaging in humans at ultrahigh magnetic fields is how to effectively decouple the resonant elements of the array. In this work, we propose a new approach using tilted microstrip array elements for improving the decoupling performance and potentially parallel imaging capability. To investigate and validate the proposed design technique, an 8-channel volume array with tilted straight-type microstrip elements was designed, capable for human imaging at the ultrahigh field of 7 Tesla. In this volume transceiver array, its electromagnetic decoupling behavior among resonant elements, RF field penetration to biological samples, and parallel imaging performance were studied through bench tests and in vivo MR imaging experiments. In this specific tilted element array design, decoupling among array elements changes with the tilted angle of the elements and the best decoupling can be achieved at certain tilted angle. In vivo human knee MR images were acquired using the tilted volume array at 7 Tesla for method validation. Results of this study demonstrated that the electromagnetic decoupling between array elements and the B1 field strength can be improved by using the tilted element method in microstrip RF coil array designs at the ultrahigh field of 7T.

  17. Tilt Angle and Footpoint Separation of Small and Large Bipolar Sunspot Regions Observed with HMI

    Science.gov (United States)

    McClintock, B. H.; Norton, A. A.

    2016-02-01

    We investigate bipolar sunspot regions and how tilt angle and footpoint separation vary during emergence and decay. The Helioseismic and Magnetic Imager on board the Solar Dynamic Observatory collects data at a higher cadence than historical records and allows for a detailed analysis of regions over their lifetimes. We sample the umbral tilt angle, footpoint separation, and umbral area of 235 bipolar sunspot regions in Helioseismic and Magnetic Imager—Debrecen Data with an hourly cadence. We use the time when the umbral area peaks as time zero to distinguish between the emergence and decay periods of each region and we limit our analysis of tilt and separation behavior over time to within ±96 hr of time zero. Tilt angle evolution is distinctly different for regions with small (≈30 MSH), midsize (≈50 MSH), and large (≈110 MSH) maximum umbral areas, with 45 and 90 MSH being useful divisions for separating the groups. At the peak umbral area, we determine median tilt angles for small (7.°6), midsize (5.°9), and large (9.°3) regions. Within ±48 hr of the time of peak umbral area, large regions steadily increase in tilt angle, midsize regions are nearly constant, and small regions show evidence of negative tilt during emergence. A period of growth in footpoint separation occurs over a 72-hr period for all of the regions from roughly 40 to 70 Mm. The smallest bipoles (Jaramillo et al. (2015) results that the sunspots appear to be two distinct populations.

  18. Determination of Solar Collector Optimum Tilt Angle for Ankara and Districts

    Directory of Open Access Journals (Sweden)

    Abdülkadir KOÇER

    2016-04-01

    Full Text Available This study that is Ankara province and districts based deals with the determination of the optimum tilt angle to maximize the performances of solar collector and solar panel. In Ankara, fixed solar collectors are usually placed at slope of 40°. In this study, annual optimum tilt angle for Ankara province and districts was calculated as 34°±1 however the optimum angles during the year were calculated between 1° and 67°. The results of this study are compared with similar studies in the literature they were found to be consistent with the results of similar studies. Also, the tilt angle was calculated for the six months periods as 15° and 56°, for seasonal periods (winter, spring, summer, autumn as 62°, 23°, 6° and 49°, respectively and solar radiation for optimum angles of inclination were found. When the tilt angle is changed only twice a year, due to increasing the amount of energy per unit area, according to the annual tilt angle fixed product they provides energy efficiency by about 5%. On the other hand, when the tilt angle is changed every month this ratio can be reached approximately 8%. For increasing the utilization efficiency of solar collectors and panels, it is recommended adjusting of the tilt angle once a month or at least twice a year.

  19. Web server for tilt-pair validation of single particle maps from electron cryomicroscopy.

    Science.gov (United States)

    Wasilewski, Sebastian; Rosenthal, Peter B

    2014-04-01

    Three-dimensional structures of biological assemblies may be calculated from images of single particles obtained by electron cryomicroscopy. A key step is the correct determination of the orientation of the particle in individual image projections. A useful tool for validation of the quality of a 3D map and its consistency with images is tilt-pair analysis. In a successful tilt-pair test, the relative angle between orientations assigned to each image of a tilt-pair agrees with the known relative rotation angle of the microscope specimen holder during the experiment. To make the procedure easy to apply to the increasing number of single particle maps, we have developed software and a web server for tilt-pair analysis. The tilt-pair analysis program reports the overall agreement of the assigned orientations with the known tilt angle and axis of the experiment and the distribution of tilt transformations for individual particles recorded in a single image field. We illustrate application of the validation tool to several single particle specimens and describe how to interpret the scores.

  20. ({alpha},{eta}) phase diagrams in tilted chiral smectics

    Energy Technology Data Exchange (ETDEWEB)

    Rjili, M., E-mail: medrjili@yahoo.fr [Laboratoire de Physique de la Matiere Molle et de la Modelisation Electromagnetique, Faculte des Sciences de Tunis, Universite Tunis El Manar, 2092 El Manar Tunis (Tunisia); Marcerou, J.P., E-mail: marcerou@crpp-bordeaux.cnrs.fr [Centre de Recherches Paul Pascal, 115, Av. Albert-Schweitzer, 33600 Pessac (France); Gharbi, A.; Othman, T. [Laboratoire de Physique de la Matiere Molle et de la Modelisation Electromagnetique, Faculte des Sciences de Tunis, Universite Tunis El Manar, 2092 El Manar Tunis (Tunisia)

    2013-02-01

    The polymorphism of tilted chiral smectics liquid crystals is incredibly rich and encompasses many subphases such as SmC{sub A}{sup Low-Asterisk }; SmC{sub Fi1}{sup Low-Asterisk }; SmC{sub Fi2}{sup Low-Asterisk }; SmC{sup Low-Asterisk }; SmC{sub {alpha}}{sup Low-Asterisk }. The continuum theory established by Marcerou (2010) is used to derive an expression for the free energy density of those subphases. The minimization of this free energy is obtained through a combination of analytical and numerical methods. It leads to a phase diagram built in the ({alpha},{eta}) plane where {alpha} is local angular parameter and {eta} describes the variation of the temperature. From this graphical representation, many experimentally observed phase sequences of ferroelectric liquid crystals can be explained, even them including subphases which were recently observed like the SmC{sub 5}{sup Low-Asterisk} and the SmC{sub 6}{sup Low-Asterisk} ones. However, it should be emphasized that the details of predicted phase diagram are strongly dependent on the compound studied.

  1. Simulations of thermal conductance across tilt grain boundaries in graphene

    Institute of Scientific and Technical Information of China (English)

    Peng Wang; Bo Gong; Qiong Feng; Hong-Tao Wang

    2012-01-01

    Non-equilibrium molecular dynamics (MD) method was performed to simulate the thermal transportation process in graphene nanoribbons (GNRs).A convenient way was conceived to introduce tilt grain boundaries (GBs) into the graphene lattice by repetitive removing C atom rows along certain directions.Comprehensive MD simulations reveal that larger-angle GBs are effective thermal barriers and substantially reduce the average thermal conductivity of GNRs.The GB thermal conductivity is ~ 10 W.m-1·K-1 for a bicrystal GNR with a misorientation of 21.8°,which is ~97% less than that of a prefect GNR with the same size.The total thermal resistance has a monotonic dependence on the density of the 5-7 defects along the GBs.A theoretical model is proposed to capture this relation and resolve the contributions by both the reduction in the phonon mean free path and the defect-induced thermal resistance.

  2. Tilt table test today-state of the art

    Institute of Scientific and Technical Information of China (English)

    Nicholay Teodorovich; Moshe Swissa

    2016-01-01

    A tilt table test(TTT) is an inexpensive, noninvasive tool for the differential diagnosis of syncope and orthostatic intolerance and has good diagnostic yield. The autonomic system malfunction which underlines the reflex syncope is manifested as either hypotension or bradycardia, while an orthostatic challenge is applied. The timing of the response to the orthostatic challenge, as well as the predominant component of the response help to differentiate between various forms of neurocardiogenic syncope, orthostatic hypotension and non-cardiovascular conditions(e.g., pseudosyncope). Medications, such as isoproterenol and nitrates, may increase TTT sensitivity. Sublingual nitrates are easiest to administer without the need of venous access. TTT can be combined with carotid sinus massage to evaluate carotid sinus hypersensitivity, which may not be present in supine position. TTT is not useful to access the response to treatment. Recently, implantable loop recorders(ILR) have been used to document cardioinhibitory reflex syncope, because pacemakers are beneficial in many of these patients, especially those over 45 years of age. The stepwise use of both TTT and ILR is a promising approach in these patients. Recently, TTT has been used for indications other than syncope, such as assessment of autonomic function in Parkinson’s disease and its differentiation from multiple system atrophy.

  3. "Tilt" in color space: Hue changes induced by chromatic surrounds.

    Science.gov (United States)

    Klauke, Susanne; Wachtler, Thomas

    2015-01-01

    The perceived color of a chromatic stimulus is influenced by the chromaticity of its surround. To investigate these influences along the dimension of hue, we measured hue changes induced in stimuli of different hues by isoluminant chromatic surrounds. Generally, induced hue changes were directed in color space away from the hue of the inducing surround and depended on the magnitude on the hue difference between stimulus and surround. With increasing difference in hue between stimulus and surround, induced hue changes increased up to a maximum and then decreased for larger differences. This qualitative pattern was similar for different inducers, but quantitatively, induction was weaker along some directions in cone-opponent color space than along other directions. The strongest induction effects were found along an oblique, blue-yellow axis that corresponds to the daylight axis. The overall pattern of the induction effect shows similarities to the well-known tilt effect, where shifts in perceived angle of oriented stimuli are induced by oriented surrounds. This suggests analogous neural representations and similar mechanisms of contextual processing for different visual features such as orientation and color.

  4. Simulation Analysis of Tilted Polyhedron-Shaped Thermoelectric Elements

    Science.gov (United States)

    Meng, Xiangning; Suzuki, Ryosuke O.

    2015-06-01

    The generation of thermoelectricity is considered a promising approach to harness the waste heat generated in industries, automobiles, gas fields, and other man-made processes. The waste heat can be converted to electricity via a thermoelectric (TE) generator. In this light, the generator performance depends on the geometric configuration of its constituent elements as well as their material properties. Our previous work reported TE behaviors for modules consisting of parallelogram-shaped elements, because elements with tilted laminate structures provide increased mechanical stability and efficient heat-transferring ability from the hot surface to the cold surface. Here, we study TE elements in the shape of a polyhedron that is obtained by mechanically truncating the edges of a parallelogram element in order to further enhance the generator performance and reduce TE material usage. The TE performance of the modules consisting of these polyhedron elements is numerically simulated by using the finite-volume method. The output power, voltage, and current of the polyhedral TE module are greater than those of the parallelogram-element module. The polyhedron shape positively affects heat transfer and the flow of electric charges in the light of increasing the efficiency of conversion from heat to electricity. By varying the shape of the truncated portions, we determine the optimal shape that enables homogeneous heat flux distribution and slow diffusion of thermal energy to obtain the better efficiency of conversion of heat into electricity. We believe that the findings of our study can significantly contribute to the design policy in TE generation.

  5. Tilt aftereffect following adaptation to translational Glass patterns.

    Science.gov (United States)

    Pavan, Andrea; Hocketstaller, Johanna; Contillo, Adriano; Greenlee, Mark W

    2016-03-23

    Glass patterns (GPs) consist of randomly distributed dot pairs (dipoles) whose orientations are determined by specific geometric transforms. We assessed whether adaptation to stationary oriented translational GPs suppresses the activity of orientation selective detectors producing a tilt aftereffect (TAE). The results showed that adaptation to GPs produces a TAE similar to that reported in previous studies, though reduced in amplitude. This suggests the involvement of orientation selective mechanisms. We also measured the interocular transfer (IOT) of the GP-induced TAE and found an almost complete IOT, indicating the involvement of orientation selective and binocularly driven units. In additional experiments, we assessed the role of attention in TAE from GPs. The results showed that distraction during adaptation similarly modulates the TAE after adapting to both GPs and gratings. Moreover, in the case of GPs, distraction is likely to interfere with the adaptation process rather than with the spatial summation of local dipoles. We conclude that TAE from GPs possibly relies on visual processing levels in which the global orientation of GPs has been encoded by neurons that are mostly binocularly driven, orientation selective and whose adaptation-related neural activity is strongly modulated by attention.

  6. Effects of Frequency and Motion Paradigm on Perception of Tilt and Translation During Periodic Linear Acceleration

    Science.gov (United States)

    Beaton, K. H.; Holly, J. E.; Clement, G. R.; Wood, Scott J.

    2009-01-01

    Previous studies have demonstrated an effect of frequency on the gain of tilt and translation perception. Results from different motion paradigms are often combined to extend the stimulus frequency range. For example, Off-Vertical Axis Rotation (OVAR) and Variable Radius Centrifugation (VRC) are useful to test low frequencies of linear acceleration at amplitudes that would require impractical sled lengths. The purpose of this study was to compare roll-tilt and lateral translation motion perception in 12 healthy subjects across four paradigms: OVAR, VRC, sled translation and rotation about an earth-horizontal axis. Subjects were oscillated in darkness at six frequencies from 0.01875 to 0.6 Hz (peak acceleration equivalent to 10 deg, less for sled motion below 0.15 Hz). Subjects verbally described the amplitude of perceived tilt and translation, and used a joystick to indicate the direction of motion. Consistent with previous reports, tilt perception gain decreased as a function of stimulus frequency in the motion paradigms without concordant canal tilt cues (OVAR, VRC and Sled). Translation perception gain was negligible at low stimulus frequencies and increased at higher frequencies. There were no significant differences between the phase of tilt and translation, nor did the phase significantly vary across stimulus frequency. There were differences in perception gain across the different paradigms. Paradigms that included actual tilt stimuli had the larger tilt gains, and paradigms that included actual translation stimuli had larger translation gains. In addition, the frequency at which there was a crossover of tilt and translation gains appeared to vary across motion paradigm between 0.15 and 0.3 Hz. Since the linear acceleration in the head lateral plane was equivalent across paradigms, differences in gain may be attributable to the presence of linear accelerations in orthogonal directions and/or cognitive aspects based on the expected motion paths.

  7. Combined influence of visual scene and body tilt on arm pointing movements: gravity matters!

    Science.gov (United States)

    Scotto Di Cesare, Cécile; Sarlegna, Fabrice R; Bourdin, Christophe; Mestre, Daniel R; Bringoux, Lionel

    2014-01-01

    Performing accurate actions such as goal-directed arm movements requires taking into account visual and body orientation cues to localize the target in space and produce appropriate reaching motor commands. We experimentally tilted the body and/or the visual scene to investigate how visual and body orientation cues are combined for the control of unseen arm movements. Subjects were asked to point toward a visual target using an upward movement during slow body and/or visual scene tilts. When the scene was tilted, final pointing errors varied as a function of the direction of the scene tilt (forward or backward). Actual forward body tilt resulted in systematic target undershoots, suggesting that the brain may have overcompensated for the biomechanical movement facilitation arising from body tilt. Combined body and visual scene tilts also affected final pointing errors according to the orientation of the visual scene. The data were further analysed using either a body-centered or a gravity-centered reference frame to encode visual scene orientation with simple additive models (i.e., 'combined' tilts equal to the sum of 'single' tilts). We found that the body-centered model could account only for some of the data regarding kinematic parameters and final errors. In contrast, the gravity-centered modeling in which the body and visual scene orientations were referred to vertical could explain all of these data. Therefore, our findings suggest that the brain uses gravity, thanks to its invariant properties, as a reference for the combination of visual and non-visual cues.

  8. RE-EXAMINING SUNSPOT TILT ANGLE TO INCLUDE ANTI-HALE STATISTICS

    Energy Technology Data Exchange (ETDEWEB)

    McClintock, B. H. [University of Southern Queensland, Toowoomba, 4350 (Australia); Norton, A. A. [HEPL, Stanford University, Palo Alto, CA 94305 (United States); Li, J., E-mail: u1049686@umail.usq.edu.au, E-mail: aanorton@stanford.edu, E-mail: jli@igpp.ucla.edu [Department of Earth, Planetary, and Space Sciences, University of California at Los Angeles, Los Angeles, CA 90095 (United States)

    2014-12-20

    Sunspot groups and bipolar magnetic regions (BMRs) serve as an observational diagnostic of the solar cycle. We use Debrecen Photohelographic Data (DPD) from 1974-2014 that determined sunspot tilt angles from daily white light observations, and data provided by Li and Ulrich that determined sunspot magnetic tilt angle using Mount Wilson magnetograms from 1974-2012. The magnetograms allowed for BMR tilt angles that were anti-Hale in configuration, so tilt values ranged from 0 to 360° rather than the more common ±90°. We explore the visual representation of magnetic tilt angles on a traditional butterfly diagram by plotting the mean area-weighted latitude of umbral activity in each bipolar sunspot group, including tilt information. The large scatter of tilt angles over the course of a single cycle and hemisphere prevents Joy's law from being visually identified in the tilt-butterfly diagram without further binning. The average latitude of anti-Hale regions does not differ from the average latitude of all regions in both hemispheres. The distribution of anti-Hale sunspot tilt angles are broadly distributed between 0 and 360° with a weak preference for east-west alignment 180° from their expected Joy's law angle. The anti-Hale sunspots display a log-normal size distribution similar to that of all sunspots, indicating no preferred size for anti-Hale sunspots. We report that 8.4% ± 0.8% of all bipolar sunspot regions are misclassified as Hale in traditional catalogs. This percentage is slightly higher for groups within 5° of the equator due to the misalignment of the magnetic and heliographic equators.

  9. Sauter-Schwinger like tunneling in tilted Bose-Hubbard lattices in the Mott phase

    CERN Document Server

    Queisser, Friedemann; Schützhold, Ralf

    2011-01-01

    We study the Mott phase of the Bose-Hubbard model on a tilted lattice. On the (Gutzwiller) mean-field level, the tilt has no effect -- but quantum fluctuations entail particle-hole pair creation via tunneling. For small potential gradients (long-wavelength limit), we derive a quantitative analogy to the Sauter-Schwinger effect, i.e., electron-positron pair creation out of the vacuum by an electric field. For large tilts, we obtain resonant tunneling related to Bloch oscillations.

  10. Eye torsion and the apparent horizon under head tilt and visual field rotation

    Science.gov (United States)

    Merker, B. H.; Held, R.

    1981-01-01

    Two different experimental manipulations, namely head tilt and the viewing of a visual display rotating around the line of sight, induce torsional displacements of the eyes and a tilting of the apparent horizon. The present study examines the routes by which visual (field rotation) and otolith-proprioceptive (head tilt) sources of afference influence horizon judgments. In particular, the relationship between torsional eye movements and horizon estimates is addressed. The results indicate that visual and otolith-proprioceptive information sum directly in their influence on eye torsion, but interact more complexly in horizon estimates, indicating a dissociation of their central determinants.

  11. The cone phase of liquid crystals: Triangular lattice of double-tilt cylinders

    Indian Academy of Sciences (India)

    Yashodhan Hatwalne; N V Madhusudana

    2003-08-01

    We predict the existence of a new defect-lattice phase near the nematic–smectic-C (NC) transition. This tilt-analogue of the blue phase is a lattice of double-tilt cylinders which are disclination lines in the smectic layer normal as well as the c-field. We discuss the structure and stability of the cone phase. We suggest that many ‘nematics’ exhibiting short range layering and tilt order may in fact be in the molten cone phase, which is a line liquid.

  12. Optimum Tilt Angle for Photovoltaic Solar Panels in Zomba District, Malawi

    OpenAIRE

    B. Kamanga; Mlatho, J. S. P.; Mikeka, C.; C. Kamunda

    2014-01-01

    A study to determine the optimum tilt angle for installing photovoltaic solar panels in Zomba district, Malawi, has been conducted. The study determined the optimum monthly tilt angles of PV solar panels and the seasonal adjustments needed for the panels in order to collect maximum solar radiation throughout the year. In this study, global solar radiation (GSR) on four tilted surfaces was measured. The north-facing surfaces were titled at angles of 0°, 15°, 20°, and 25°. The GSR data was used...

  13. THE EFFECT OF TILT ANGLE ON PERFORNCE OF PHOTOVOLTAIC SYSTEMS%光伏阵列倾角对性能影响实验研究

    Institute of Scientific and Technical Information of China (English)

    陈维; 沈辉; 刘勇

    2009-01-01

    对8块不同朝向和倾角的太阳电池组件输出情况进行了为期一年多的测试,并对实验结果进行了详细的分析和研究.得出:水平布置以及小倾角布置时,灰尘、雨水等因素对光伏阵列产能有较大影响;全年以朝向正南220倾角太阳电池组件产出的电能最多.%An experimental PV system with 8 different tilt and azimuthal PV modules was installed at the Solar System Re-search Institute of Sun-Yat-SEN University. The data acquired by the system from Feb. 2005 to Feb. 2006 is showed in this paper. It is found that: the dust, rain and other factors could influence the output of the total system greatly, when the PV modules are horizontally mounted or with small tilt angle; besides, the south facing PV module with 22 degree tilt angle generates the most power.

  14. 汶川地震强震动地面倾斜研究%Study of ground surface tilts from strong motion records of the Wenchuan earthquake

    Institute of Scientific and Technical Information of China (English)

    彭小波; 李小军

    2012-01-01

    根据三分量强震动传感器水平摆和竖向摆对倾斜的动力响应差异,利用谱比法计算出汶川Ms8.0地震中近断层强震动的断层法线方向和平行方向的同震地面倾斜.结果表明,本次地震中强震动观测台处地面倾斜一般小于1°,影响频段主要在0.1 Hz以下,发生较大倾斜的台站主要在距地表破裂迹线30 km以内,在100 km之外或水平向加速度幅值均方根在200 cm/s2以下时很少发生0.01°以上的同震地面倾斜.总体上看,上盘区域的倾斜值普遍小于下盘区域,法线方向倾斜值一般大于平行线方向倾斜值.位于前山断裂与中央断裂之间区域的绵竹清平台谱比较低但平缓且频带较宽,可能反应了该区域的运动特殊性,而汶川卧龙台则显示了上盘边缘区域地面倾斜较大.逆冲段与走滑段台站倾斜对比显示,地面倾斜可能受局部场地条件影响较大.%Based on the difference of dynamic response to tilts between horizontal pendulums and vertical pendulum, spectral ratio method was applied to estimate the coseismic surface tilts deduced from strong motion records of the Wen-chuan earthquake. The result shows that the ground surface tilts are generally less than 1 degree and mainly appears within 30 km to fault rupture surface traces, while rarely discovered in the area outside 100 km or root-mean-squared horizontal peak accelerations are less than 200 cm/s2. The frequency band influenced by tilts is less than 0. 1 Hz. In general, tilts in hanging wall is greater than that in footwall in near fault areas, and tilts in normal direction of fault is less than those in parallel direction. The spectral ratio of Qingping station located between central fault and front mount fault is relatively low and stable, which may imply ae special movement feature of the area. The tilts of Wolong station may be controlled by deformation transition from the hanging wall to laterally stationary area. Comparison of tilts

  15. Interpretation of Gravity Data using 3D Euler Deconvolution, Tilt Angle, Horizontal Tilt Angle and Source Edge Approximation of the North-West Himalaya

    Science.gov (United States)

    Ghosh, Gopal K.

    2016-08-01

    The collision of the Indian plate and the Eurasian plate created shortening and imbrications with thrusting and faulting which influences northward tectonic movement. This plate movement has divided the Himalaya into four parts, viz. Outer Himalaya, Lesser Himalaya, Greater Himalaya, and Tethys Himalaya. The crystalline basement rock plays an imperative role for structural and tectonic association. The study has been carried out near Rishikesh-Badrinath neighborhood in the northwestern part of the Himalayan girdle with multifarious tectonic set up with thrusted and faulted geological setting. In this study area, 3D Euler deconvolution, horizontal gradient analysis, tilt angle (TILT) and horizontal tilt angle (TDX) analysis have been carried out using gravity data to delineate the subsurface geology and heterogeneity in the northwestern part of Himalaya. The Euler depth solutions suggest the source depth of about 12 km and various derivative analyses suggest the trend of the delineation thrust-fault boundaries along with the dip and strike direction in the study area.

  16. Transient influence of end-tidal carbon dioxide tension on the postural restraint in cerebral perfusion

    DEFF Research Database (Denmark)

    Immink, R.V.; Truijen, J.; Secher, Niels H.

    2009-01-01

    In the upright position, cerebral blood flow is reduced, maybe because arterial carbon dioxide partial pressure (Pa(CO(2))) decreases. We evaluated the time-dependent influence of a reduction in Pa(CO(2)), as indicated by the end-tidal Pco(2) tension (Pet(CO(2))), on cerebral perfusion during head......-up tilt. Mean arterial pressure, cardiac output, middle cerebral artery mean flow velocity (MCA V(mean)), and dynamic cerebral autoregulation at supine rest and 70 degrees head-up tilt were determined during free breathing and with Pet(CO(2)) clamped to the supine level. The postural changes in central...

  17. 'Abnormal' angle response curves of TW/Rs for near zero tilt and high tilt channeling implants

    Energy Technology Data Exchange (ETDEWEB)

    Guo Baonian; Gossmann, Hans-Joachim; Toh, Terry; Colombeau, Benjamin; Todorov, Stan; Sinclair, Frank; Shim, Kyu-Ha; Henry, Todd [Applied Materials - Varian Semiconductor Equipment, 35 Dory Road, Gloucester, MA 01930 (United States)

    2012-11-06

    Angle control has been widely accepted as the key requirement for ion implantation in semiconductor device processing. From an ion implanter point of view, the incident ion direction should be measured and corrected by suitable techniques, such as XP-VPS for the VIISta implanter platform, to ensure precision ion placement in device structures. So called V-curves have been adopted to generate the wafer-based calibration using channeling effects as the Si lattice steer ions into a channeling direction. Thermal Wave (TW) or sheet resistance (Rs) can be used to determine the minimum of the angle response curve. Normally it is expected that the TW and Rs have their respective minima at identical angles. However, the TW and Rs response to the angle variations does depend on factors such as implant species, dose, and wafer temperature. Implant damage accumulation effects have to be considered for data interpretation especially for some 'abnormal' V-curve data. In this paper we will discuss some observed 'abnormal' angle responses, such as a) TW/Rs reverse trend for Arsenic beam, 2) 'W' shape of Rs Boron, and 3) apparent TW/Rs minimum difference for high tilt characterization, along with experimental data and TCAD simulations.

  18. Degree-degree dependencies in random graphs with heavy-tailed degrees

    NARCIS (Netherlands)

    Hofstad, van der Remco; Litvak, Nelly

    2014-01-01

    Mixing patterns in large self-organizing networks, such as the Internet, the World Wide Web, social, and biological networks are often characterized by degree-degree dependencies between neighboring nodes. In assortative networks, the degree-degree dependencies are positive (nodes with similar degre

  19. Degree-Degree Dependencies in Random Graphs with Heavy-Tailed Degrees

    NARCIS (Netherlands)

    van der Hofstad, Remco; Litvak, Nelli

    2014-01-01

    Mixing patterns in large self-organizing networks, such as the Internet, the World Wide Web, social, and biological networks are often characterized by degree-degree dependencies between neighboring nodes. In assortative networks, the degree-degree dependencies are positive (nodes with similar

  20. Reconciliation of local and long-range tilt correlations in underdoped La2-xBaxCuO4 (0 ≤x ≤0.155 )

    Science.gov (United States)

    Bozin, Emil S.; Zhong, Ruidan; Knox, Kevin R.; Gu, Genda; Hill, John P.; Tranquada, John M.; Billinge, Simon J. L.

    2015-02-01

    A long-standing puzzle regarding the disparity of local and long-range CuO6 octahedral tilt correlations in the underdoped regime of La2-xBaxCuO4 is addressed by utilizing complementary neutron powder diffraction and inelastic neutron scattering (INS) approaches. This system is of interest because of the strong depression of the bulk superconducting transition at x =1 /8 in association with charge and spin stripe order. The latter unidirectional order is tied to Cu-O bond-length anisotropy present in the so-called low-temperature tetragonal (LTT) phase. On warming, the lattice exhibits two sequential structural transitions, involving changes in the CuO6 tilt pattern, first to the low-temperature orthorhombic (LTO) and then the high-temperature tetragonal (HTT) phase. Despite the changes in static order, inspection of the instantaneous local atomic structure suggests that the LTT-type tilts persist through the transitions. Analysis of the INS spectra for the x =1 /8 composition reveals the dynamic nature of the LTT-like tilt fluctuations within the LTO and HTT phases. Within the low-temperature phase, the Cu-O bond-length splitting inferred from lattice symmetry and fitted atomic position parameters reaches a maximum of 0.3 % at x =1 /8 , suggesting that electron-phonon coupling may contribute to optimizing the structure to stabilize stripe order. This splitting is much too small to be resolved in the pair distribution function, and in fact we do not resolve any enhancement of the instantaneous bond-length distribution in association with stripe order. This study exemplifies the importance of a systematic approach using complementary techniques when investigating systems exhibiting a large degree of complexity and subtle structural responses.

  1. Stable Isotopes of Tilted Ignimbrite Calderas in Nevada

    Science.gov (United States)

    John, D. A.; Watts, K. E.; Hofstra, A. H.; Colgan, J. P.; Henry, C.; Bindeman, I. N.

    2013-12-01

    Mid-Tertiary calderas are exceptionally well exposed in tilted fault blocks of the northern Great Basin, facilitating detailed evolutionary models of their magmatic-hydrothermal systems. The 29.4 Ma Job Canyon caldera, the oldest of 3 overlapping calderas in the Stillwater Range, west-central Nevada, is tilted ~90° exposing a 10-km-thick section of the crust. Large parts of the >7 km-diameter caldera system, including >2 km thickness of intracaldera rhyolitic tuff, lower parts of an ~2 km thick sequence of post-caldera intermediate lavas, and the upper 500 m of the resurgent granodioritic IXL pluton, were pervasively altered to propylitic, argillic, and sericitic assemblages. Sparse quartz×calcite veins cut the tuff. δ18O values of altered whole rock samples range from +4.8 to -9.1‰ but are mostly -6 to -9‰ at paleodepths >2 km. Calculated magmatic δ18O and δD values range from +6.4 to 8.2‰ and ~-70‰, respectively. Calculated fluid compositions using temperatures from fluid inclusions and mineral assemblages are δ18OH2O=-9.5 to -15‰ and δDH2O=-125 to -135‰ (chlorite) and -70 to -80‰ (epidote). Chlorite-whole rock data suggest fluids that were derived from moderately 18O-exchanged meteoric water. Fault blocks in north-central Nevada expose a >5 km upper crustal cross section through the 12-17 x 20 km, 34 Ma Caetano caldera, including >3 km thickness intracaldera rhyolitic Caetano Tuff. Asymmetric caldera subsidence left a depression >1 km deep partly filled with a lake. Magma resurgence and emplacement of shallow granite porphyry plutons drove a hydrothermal system that altered >120 km2 of the caldera to depths >1.5 km. Alteration was focused in an early granite porphyry intrusion and surrounding upper Caetano Tuff and lacustrine sediments. Early pervasive quartz-kaolinite-pyrite alteration grades outward and downward into more restricted quartz-illite/smectite-pyrite alteration. Hematite, quartz, and barite veins and hydrothermal breccias cut

  2. Description of multi-quasiparticle bands by the tilted axis cranking model 21.60.-n; High K rotational bands; Tilted axis cranking; Multi-quasiparticle configurations

    CERN Document Server

    Frauendorf, S

    2000-01-01

    The selfconsistent cranking approach is extended to the case of rotation about an axis which is tilted with respect to the principal axes of the deformed potential (Tilted Axis Cranking). Expressions for the energies and the intra bands electro-magnetic transition probabilities are given. The mean field solutions are interpreted in terms of quantal rotational states. The construction of the quasiparticle configurations and the elimination of spurious states is discussed. The application of the theory to high spin data is demonstrated by analyzing the multi-quasiparticle bands in the nuclides with N=102,103 and Z=71,72,73.

  3. Quantitative modeling of degree-degree correlation in complex networks

    CERN Document Server

    Niño, Alfonso

    2013-01-01

    This paper presents an approach to the modeling of degree-degree correlation in complex networks. Thus, a simple function, \\Delta(k', k), describing specific degree-to- degree correlations is considered. The function is well suited to graphically depict assortative and disassortative variations within networks. To quantify degree correlation variations, the joint probability distribution between nodes with arbitrary degrees, P(k', k), is used. Introduction of the end-degree probability function as a basic variable allows using group theory to derive mathematical models for P(k', k). In this form, an expression, representing a family of seven models, is constructed with the needed normalization conditions. Applied to \\Delta(k', k), this expression predicts a nonuniform distribution of degree correlation in networks, organized in two assortative and two disassortative zones. This structure is actually observed in a set of four modeled, technological, social, and biological networks. A regression study performed...

  4. Visual homing with a pan-tilt based stereo camera

    Science.gov (United States)

    Nirmal, Paramesh; Lyons, Damian M.

    2013-01-01

    Visual homing is a navigation method based on comparing a stored image of the goal location and the current image (current view) to determine how to navigate to the goal location. It is theorized that insects, such as ants and bees, employ visual homing methods to return to their nest. Visual homing has been applied to autonomous robot platforms using two main approaches: holistic and feature-based. Both methods aim at determining distance and direction to the goal location. Navigational algorithms using Scale Invariant Feature Transforms (SIFT) have gained great popularity in the recent years due to the robustness of the feature operator. Churchill and Vardy have developed a visual homing method using scale change information (Homing in Scale Space, HiSS) from SIFT. HiSS uses SIFT feature scale change information to determine distance between the robot and the goal location. Since the scale component is discrete with a small range of values, the result is a rough measurement with limited accuracy. We have developed a method that uses stereo data, resulting in better homing performance. Our approach utilizes a pan-tilt based stereo camera, which is used to build composite wide-field images. We use the wide-field images combined with stereo-data obtained from the stereo camera to extend the keypoint vector described in to include a new parameter, depth (z). Using this info, our algorithm determines the distance and orientation from the robot to the goal location. We compare our method with HiSS in a set of indoor trials using a Pioneer 3-AT robot equipped with a BumbleBee2 stereo camera. We evaluate the performance of both methods using a set of performance measures described in this paper.

  5. Probing the Universe's Tilt with the Cosmic Infrared Background Dipole

    Science.gov (United States)

    Fixsen, D. J.; Kashlinsky, A.

    2011-06-01

    Conventional interpretation of the observed cosmic microwave background (CMB) dipole is that all of it is produced by local peculiar motions. Alternative explanations requiring part of the dipole to be primordial have received support from measurements of large-scale bulk flows. A test of the two hypotheses is whether other cosmic dipoles produced by collapsed structures later than the last scattering coincide with the CMB dipole. One background is the cosmic infrared background (CIB) whose absolute spectrum was measured to ~30% by the COBE satellite. Over the 100-500 μm wavelength range its spectral energy distribution can provide a probe of its alignment with the CMB. This is tested with the COBE FIRAS data set which is available for such a measurement because of its low noise and frequency resolution which are important for Galaxy subtraction. Although the FIRAS instrument noise is in principle low enough to determine the CIB dipole, the Galactic foreground is sufficiently close spectrally to keep the CIB dipole hidden. A similar analysis is performed with DIRBE, which—because of the limited frequency coverage—provides a poorer data set. We discuss strategies for measuring the CIB dipole with future instruments to probe the tilt and apply it to the Planck, Herschel, and the proposed Pixie missions. We demonstrate that a future FIRAS-like instrument with instrument noise a factor of ~10 lower than FIRAS would make a statistically significant measurement of the CIB dipole. We find that the Planck and Herschel data sets will not allow a robust CIB dipole measurement. The Pixie instrument promises a determination of the CIB dipole and its alignment with either the CMB dipole or the dipole galaxy acceleration vector.

  6. Integrated polymer polarization rotator based on tilted laser ablation

    Science.gov (United States)

    Poulopoulos, Giannis; Kalavrouziotis, Dimitrios; Missinne, Jeroen; Bosman, Erwin; Van Steenberge, Geert; Apostolopoulos, Dimitrios; Avramopoulos, Hercules

    2017-02-01

    sidewalls, employing the tilted laser ablation technology, currently available at CMST. Therefore, the aforementioned simulation steps adhere fully to the respective design rules, taking into account the anticipated fabrication variations

  7. Measurements of sunspot group tilt angles for solar cycles 19-24

    Science.gov (United States)

    Isik, Seda; Isik, Emre

    2016-07-01

    The tilt angle of a sunspot group is a critical quantity in the surface transport magnetic flux on global scales, playing a role in the solar dynamo. To investigate Joy's law for four cycles, we measured the tilt angles of sunspot groups for solar cycles 19-24. We have developed an IDL routine, which allows the user to interactively select and measure sunspot positions and areas on the solar disc, using the sunspot drawing database of Kandilli Observatory. The method is similar to that used by others in the literature, with the exception that sunspot groups were identified manually, which has improved the accuracy of the tilt angles. We present cycle averages of the tilt angle and compare the results with the existing data in the literature.

  8. A novel control method for on-off gain and gain tilt of fiber Raman amplifiers

    Institute of Scientific and Technical Information of China (English)

    Xue Feng(冯雪); Wei Zhang(张巍); Xiaoming Liu(刘小明); Jiangde Peng(彭江得)

    2004-01-01

    Considering spectrum tilt due to signal-to-signal Raman scattering (SSRS) in backward distributed fiber Raman amplifiers (B-DFRA), an inverse tilted on-off gain profile is adopted to achieve flat net gain. A simple approximate linear relationship of pump power at each wavelength versus on-off gain level and tilt was derived numerically and experimentally so that a novel control method was established. Since there are only 3 pre-determinable constants required for individual pump wave, it is easy to be realized. As an example, maximum errors less than 0.2 and 0.4 dB respectively for average gain and gain tilt were achieved over C+L band in 100-km back-pumped standard single-mode fiber (SMF) experimentally.

  9. A mechanism for the dependence of sunspot group tilt angles on cycle strength

    CERN Document Server

    Işık, Emre

    2015-01-01

    The average tilt angle of sunspot groups emerging throughout the solar cycle determines the net magnetic flux crossing the equator, which is correlated with the strength of the subsequent cycle. I suggest that a deep-seated, non-local process can account for the observed cycle-dependent changes in the average tilt angle. Motivated by helioseismic observations indicating cycle-scale variations in the sound speed near the base of the convection zone, I determined the effect of a thermally perturbed overshoot region on the stability of flux tubes and on the tilt angles of emerging flux loops. I found that 5-20 K of cooling is sufficient for emerging flux loops to reproduce the reported amplitude of cycle-averaged tilt angle variations, suggesting that it is a plausible effect responsible for the nonlinearity of the solar activity cycle.

  10. Tilt meters for the Alignment System of the CMS Experiment: Users Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Alberdi, J.; Arce, P.; Barcala, J.M.; Calvo, E.; Ferrando, A.; Josa, M.I.; Molinero, A.; Navarrete, J.; Oller, J.C.; Yuste, C.

    2007-09-27

    We present the instructions for the use of the electrolytic tilt meters installed in the link alignments system of the CMS experimental and give the Data Base to be used as a Handbook during CMS operation. (Author) 16 refs.

  11. Core Quadrant Power Tilt Induced by Control Rods Axial Position Mismatch

    Energy Technology Data Exchange (ETDEWEB)

    Son, Seungbeom; Lee, Changhee; Woo, Haeseuk; Jung, Yilsup [KEPCO Nuclear Fuel, Daejeon (Korea, Republic of); Kim, Yonghee [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-05-15

    If the limits are not met, plant operation should be restricted at various conditions. Actually, core quadrant power tilt in many nuclear power plants has been occurred frequently. This study deals with the various general causes of the core quadrant power tilt, including the control rods axial position mismatch induced quadrant power tilt problem. Based on the simulation results in each control rods axial position mismatch in a same control bank, it was found that some control rods axial position mismatch (simply around 10 steps difference) can induce quadrant power tilt relatively high (around 1.5%). With the other causes induced QPT, it may exceed the technical specification limit (2%). So it is needed to drive the control rods in detail during the operation including power change mode.

  12. Tilt aftereffects in a self-organizing model of the primary visual cortex.

    Science.gov (United States)

    Bednar, J A; Miikkulainen, R

    2000-07-01

    RF-LISSOM, a self-organizing model of laterally connected orientation maps in the primary visual cortex, was used to study the psychological phenomenon known as the tilt aftereffect. The same self-organizing processes that are responsible for the long-term development of the map are shown to result in tilt aftereffects over short timescales in the adult. The model permits simultaneous observation of large numbers of neurons and connections, making it possible to relate high-level phenomena to low-level events, which is difficult to do experimentally. The results give detailed computational support for the long-standing conjecture that the direct tilt aftereffect arises from adaptive lateral interactions between feature detectors. They also make a new prediction that the indirect effect results from the normalization of synaptic efficacies during this process. The model thus provides a unified computational explanation of self-organization and both the direct and indirect tilt aftereffect in the primary visual cortex.

  13. Confocal X-ray fluorescence micro-spectroscopy experiment in tilted geometry

    Energy Technology Data Exchange (ETDEWEB)

    Czyzycki, Mateusz, E-mail: Mateusz.Czyzycki@desy.de [DESY Photon Science, Notkestr. 85, D-22607 Hamburg (Germany); AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, Al. A. Mickiewicza 30, 30-059 Krakow (Poland); Wrobel, Pawel; Lankosz, Marek [AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, Al. A. Mickiewicza 30, 30-059 Krakow (Poland)

    2014-07-01

    This paper provides a generalized mathematical model to describe the intensity of primary X-ray fluorescence radiation collected in the tilted confocal geometry mode, where the collimating optics is rotated over an angle relative to a horizontal plane. The influence of newly introduced terms, which take into account the tilted geometry mode, is discussed. The model is verified with a multi-layer test sample scanned in depth. It is proved that for low-Z matrices, the rotation of the detection channel does not induce any significant differences in a reconstruction of the thickness and chemical composition of layers, so that it may safely be ignored. - Highlights: • A mathematical model for confocal XRF spectroscopy in tilted geometry was derived. • Tilted geometry influenced the analytical capabilities of XRF instrument slightly. • Thickness and the chemical composition of multi-layers were determined.

  14. Development of tilted fibre Bragg gratings using highly coherent 255 nm radiation

    Indian Academy of Sciences (India)

    O Prakash; J Kumar; R Mahakud; U Kumbhkar; S V Nakhe; S K Dixit

    2014-02-01

    This paper reports the study on development of tilted fibre Bragg gratings using highly coherent 255 nm radiation, obtained from the second harmonic generation (SHG) of copper vapour laser (CVL). The transmission and reflection spectra of the tilted fibre Bragg gratings (TFBG) were studied for the tilt angles of 0° (normal FBG), 1°, 3° and 4° between the fibre axis and the interference fringe plane. It was observed that as the angle of fibre axis and phase mask increased, the main Bragg peak shifted towards the higher wavelength and transmission dip decreased. The transmission dip of the cladding mode first increased and then decreased after reaching a maximum with the increase in the tilt angle.

  15. Reducing friction in tilting-pad bearings by the use of enclosed recesses

    DEFF Research Database (Denmark)

    Heinrichson, Niels; Santos, Ilmar

    2008-01-01

    A three-dimensional thermoelastohydrodynamic model is applied to the analysis of tilting-pad bearings with spherical pivots and equipped with deep recesses in the high-pressure regions. A potential for a 10-20% reduction in the friction loss compared to conventional plain bearing pads is documented....... Design suggestions minimizing the power loss are given for various length-to-width ratios. The tilting angle in the sliding direction is more sensitive to correct positioning of the pivot point than conventional bearing pads. Improving the performance by equipping a tilting-pad bearing with a deep recess...... therefore requires accurate analysis and design of the bearing. Similarly, a high sensitivity perpendicular to the sliding direction suggests that this method of reducing friction is more feasible when using line pivots or spring beds than when using spherical pivots for controlling the tilting angle....

  16. Modeling and experiment of the suspended seismometer concept for attenuating the contribution of tilt motion in horizontal measurements

    Science.gov (United States)

    Matichard, F.; Evans, M.; Mittleman, R.; MacInnis, M.; Biscans, S.; Dooley, K. L.; Sohier, H.; Lauriero, A.; Paris, H.; Koch, J.; Knothe, P.; Carbajo, A.; Dufort, C.

    2016-06-01

    Tilt-horizontal coupling in inertial sensors limits the performance of active isolation systems such as those used in gravitational wave detectors. Inertial rotation sensors can be used to subtract the tilt component from the signal produced by horizontal inertial sensors, but such techniques are often limited by the sensor noise of the tilt measurement. A different approach is to mechanically filter the tilt transmitted to the horizontal inertial sensor, as discussed in this article. This technique does not require an auxiliary rotation sensor and can produce a lower noise measurement. The concept investigated uses a mechanical suspension to isolate the inertial sensor from input tilt. Modeling and simulations show that such a configuration can be used to adequately attenuate the tilt transmitted to the instrument, while maintaining translation sensitivity in the frequency band of interest. The analysis is supported by experimental results showing that this approach is a viable solution to overcome the tilt problem in the field of active inertial isolation.

  17. Modeling and Experiment of the Suspended Seismometer Concept for Attenuating the Contribution of Tilt Motion in Horizontal Measurements

    CERN Document Server

    Matichard, F; Mittleman, R; McInnis, M; Biscans, S; Dooley, K L; Sohier, H; Lauriero, A; Paris, H; Koch, J; Knothe, P; Carbajo, A; Dufort, C

    2016-01-01

    Tilt-horizontal coupling in inertial sensors limits the performance of active isolation systems such as those used in gravitational wave detectors. Inertial rotation sensors can be used to subtract the tilt component from the signal produced by horizontal inertial sensors, but such techniques are often limited by the sensor noise of the tilt measurement. A different approach is to mechanically filter the tilt transmitted to the horizontal inertial sensor, as discussed in this article. This technique does not require an auxiliary rotation sensor, and can produce a lower noise measurement. The concept investigated uses a mechanical suspension to isolate the inertial sensor from input tilt. Modeling and simulations show that such a configuration can be used to adequately attenuate the tilt transmitted to the instrument, while maintaining translation sensitivity in the frequency band of interest. The analysis is supported by experimental results showing that this approach is a viable solution to overcome the tilt...

  18. Motion Perception and Manual Control Performance During Passive Tilt and Translation Following Space Flight

    Science.gov (United States)

    Clement, Gilles; Wood, Scott J.

    2010-01-01

    This joint ESA-NASA study is examining changes in motion perception following Space Shuttle flights and the operational implications of post-flight tilt-translation ambiguity for manual control performance. Vibrotactile feedback of tilt orientation is also being evaluated as a countermeasure to improve performance during a closed-loop nulling task. METHODS. Data has been collected on 5 astronaut subjects during 3 preflight sessions and during the first 8 days after Shuttle landings. Variable radius centrifugation (216 deg/s) combined with body translation (12-22 cm, peak-to-peak) is utilized to elicit roll-tilt perception (equivalent to 20 deg, peak-to-peak). A forward-backward moving sled (24-390 cm, peak-to-peak) with or without chair tilting in pitch is utilized to elicit pitch tilt perception (equivalent to 20 deg, peak-to-peak). These combinations are elicited at 0.15, 0.3, and 0.6 Hz for evaluating the effect of motion frequency on tilt-translation ambiguity. In both devices, a closed-loop nulling task is also performed during pseudorandom motion with and without vibrotactile feedback of tilt. All tests are performed in complete darkness. PRELIMINARY RESULTS. Data collection is currently ongoing. Results to date suggest there is a trend for translation motion perception to be increased at the low and medium frequencies on landing day compared to pre-flight. Manual control performance is improved with vibrotactile feedback. DISCUSSION. The results of this study indicate that post-flight recovery of motion perception and manual control performance is complete within 8 days following short-duration space missions. Vibrotactile feedback of tilt improves manual control performance both before and after flight.

  19. Tilt stability in nonlinear programming under Mangasarian-Fromovitz constraint qualification

    OpenAIRE

    Mordukhovich, B. S.; Outrata, J. (Jiří)

    2013-01-01

    The paper concerns the study of tilt stability of local minimizers in standard problems of nonlinear programming. This notion plays an important role in both theoretical and numerical aspects of optimization and has drawn a lot of attention in optimization theory and its applications, especially in recent years. Under the classical Mangasarian–Fromovitz Constraint Qualification, we establish relationships between tilt stability and some other stability notions in constrained optimization. I...

  20. Multi-orifice active tilting-pad journal bearings—Harnessing of synergetic coupling effects

    DEFF Research Database (Denmark)

    Haugaard, Martin Asger; Santos, Ilmar

    2010-01-01

    The dynamic performance of tilting-pad journal bearings with controllable radial oil injection is theoretically investigated, exploring the synergetic effect between passive elastohydrodynamics and active radial lubricant injection. The flexible tilting-pads are modelled as linearly elastic using...... finite elements. To reduce computational work, a pseudo modal reduction is applied. Curves of dynamic bearing coefficients as well as the corresponding phase-magnitude plots are presented. Strong synergy between elastohydrodynamics and active control is observed, in particular for bearings with injection...

  1. Tilt-shift eddy current probe impact on information value of response signal

    OpenAIRE

    Chudacik Vladimir; Smetana Milan

    2016-01-01

    This article deals with the possibility for increasing of the informational value of a response signal using tilt-shift eddy current probe. Numerical simulations based on the FEM method using the OPERA 3D software as well as gained experimental results are presented. The simulated cracks are evaluated at the selected eddy current probe tilts and shifts with respect to conductive plate to obtain additional data needed for its evaluation and localization. Obtained simulation results are compare...

  2. Photosensitivity control of an isotropic medium through polarization of light pulses with tilted intensity front.

    Science.gov (United States)

    Kazansky, Peter G; Shimotsuma, Yasuhiko; Sakakura, Masaaki; Beresna, Martynas; Gecevičius, Mindaugas; Svirko, Yuri; Akturk, Selcuk; Qiu, Jianrong; Miura, Kiyotaka; Hirao, Kazuyuki

    2011-10-10

    We present the first experimental evidence of anisotropic photosensitivity of an isotropic homogeneous medium under uniform illumination. Our experiments reveal fundamentally new type of light induced anisotropy originated from the hidden asymmetry of pulsed light beam with a finite tilt of intensity front. We anticipate that the observed phenomenon, which enables employing mutual orientation of a light polarization plane and pulse front tilt to control interaction of matter with ultrashort light pulses, will open new opportunities in material processing.

  3. Velocity dependence of vestibular information for postural control on tilting surfaces.

    Science.gov (United States)

    Horak, Fay B; Kluzik, JoAnn; Hlavacka, Frantisek

    2016-09-01

    Vestibular information is known to be important for postural stability on tilting surfaces, but the relative importance of vestibular information across a wide range of surface tilt velocities is less clear. We compared how tilt velocity influences postural orientation and stability in nine subjects with bilateral vestibular loss and nine age-matched, control subjects. Subjects stood on a force platform that tilted 6 deg, toes-up at eight velocities (0.25 to 32 deg/s), with and without vision. Results showed that visual information effectively compensated for lack of vestibular information at all tilt velocities. However, with eyes closed, subjects with vestibular loss were most unstable within a critical tilt velocity range of 2 to 8 deg/s. Subjects with vestibular deficiency lost their balance in more than 90% of trials during the 4 deg/s condition, but never fell during slower tilts (0.25-1 deg/s) and fell only very rarely during faster tilts (16-32 deg/s). At the critical velocity range in which falls occurred, the body center of mass stayed aligned with respect to the surface, onset of ankle dorsiflexion was delayed, and there was delayed or absent gastrocnemius inhibition, suggesting that subjects were attempting to actively align their upper bodies with respect to the moving surface instead of to gravity. Vestibular information may be critical for stability at velocities of 2 to 8 deg/s because postural sway above 2 deg/s may be too fast to elicit stabilizing responses through the graviceptive somatosensory system, and postural sway below 8 deg/s may be too slow for somatosensory-triggered responses or passive stabilization from trunk inertia.

  4. Tilting A Small Reflector For Vernier Pointing Of A Large Antenna

    Science.gov (United States)

    Veruttipong, Watt; Bathker, Dan A.

    1995-01-01

    Simple vernier pointing technique devised to facilitate scanning beam pointing of large paraboloidal reflector so line of sight of antenna sweeps out narrow cone about fixed axis (conical scan, also known as "conscan" in art). Scan effected by one of relatively small beam-waveguide reflectors or mirrors that couple signals between antenna and distant transmitting and/or receiving electronic circuits. Easier to tilt small mirror than to tilt massive antenna structure.

  5. Impaired tilt perception in Parkinson's disease: a central vestibular integration failure.

    Directory of Open Access Journals (Sweden)

    Giovanni Bertolini

    Full Text Available Impaired balance control is a hallmark symptom in Parkinson's disease (PD. Altered sensory-motor integration contributes to the deficiency. We aimed to determine whether impaired vestibular signal processing added to the disorder. We exposed patients (N = 11; 68±6y and age-matched healthy subjects (hS: N = 19; 65±11y on a motion platform in complete darkness to two consecutive forward tilt movements (12 series; N = 24; overall 288 trials and asked them to indicate which tilt was perceived larger. By combing tilt movements with translations we manipulated vestibular sensory input in order to investigate whether putative impairment resulted from a deficiency of the sensory organs (semicircular canals in 'single-SCC-cue-condition', otoliths in 'single-OT-cue-condition' themselves or to a sensory integration failure ('multi-cue-condition'.Tilt discrimination in the multi-cue-condition was inferior in patients compared to hS (p = 0.02. No significant differences between the two groups were found for both single-cue-conditions. Comparison of multi-cue-condition with a prediction resulting from the combination of both single-cue-conditions by optimal observer theory revealed that patients (p = 0.04, in contrast to hS, failed to efficiently combine SCC and OT information to improve tilt perception.We found that PD patients distinguished forward tilts less precise than hS, suggesting impaired vestibular perception. Tilt discrimination in patients, moreover, did not improve as much as in hS in conditions where both SCC and OT information was available compared to conditions where only SCC or OT cues were activated. The latter provides evidence that tilt misperception in PD most likely results from an integration failure of vestibular signals.

  6. Estimation of pelvic tilt on anteroposterior X-rays - a comparison of six parameters

    Energy Technology Data Exchange (ETDEWEB)

    Tannast, M. [University of Bern, Department of Orthopedic Surgery, Inselspital, Bern (Switzerland); New England Baptist Hospital, Center for Computer Assisted and Reconstructive Surgery, Boston, MA (United States); Tufts University School of Medicine, Boston, MA (United States); Harvard Medical School, Boston, MA (United States); Murphy, S.B. [New England Baptist Hospital, Center for Computer Assisted and Reconstructive Surgery, Boston, MA (United States); Tufts University School of Medicine, Boston, MA (United States); Harvard Medical School, Boston, MA (United States); Langlotz, F. [University of Bern, MEM Research Center for Orthopaedic Surgery, Institute for Surgical Technologies and Biomechanics, Bern (Switzerland); Anderson, S.E. [University of Bern, Department of Diagnostic Interventional and Pediatric Radiology, Bern (Switzerland); Siebenrock, K.A. [University of Bern, Department of Orthopedic Surgery, Inselspital, Bern (Switzerland)

    2006-03-15

    To compare six different parameters described in literature for estimation of pelvic tilt on an anteroposterior pelvic radiograph and to create a simple nomogram for tilt correction of prosthetic cup version in total hip arthroplasty. Simultaneous anteroposterior and lateral pelvic radiographs are taken routinely in our institution and were analyzed prospectively. The different parameters (including three distances and three ratios) were measured and compared to the actual pelvic tilt on the lateral radiograph using simple linear regression analysis. One hundred and four consecutive patients (41 men, 63 women with a mean age of 31.7 years, SD 9.2 years, range 15.7-59.1 years) were studied. The strongest correlation between pelvic tilt and one of the six parameters for both men and women was the distance between the upper border of the symphysis and the sacrococcygeal joint. The correlation coefficient was 0.68 for men (P<0.001) and 0.61 for women (P<0.001). Based on this linear correlation, a nomogram was created that enables fast, tilt-corrected cup version measurements in clinical routine use. This simple method for correcting variations in pelvic tilt on plain radiographs can potentially improve the radiologist's ability to diagnose and interpret malformations of the acetabulum (particularly acetabular retroversion and excessive acetabular overcoverage) and post-operative orientation of the prosthetic acetabulum. (orig.)

  7. Roll tilt psychophysics in rhesus monkeys during vestibular and visual stimulation.

    Science.gov (United States)

    Lewis, Richard F; Haburcakova, Csilla; Merfeld, Daniel M

    2008-07-01

    How does the brain calculate the spatial orientation of the head relative to gravity? Psychophysical measurements are critical to investigate this question, but such measurements have been limited to humans. In non-human primates, behavioral measures have focused on vestibular-mediated eye movements, which do not reflect percepts of head orientation. We have therefore developed a method to measure tilt perception in monkeys, derived from the subjective visual vertical (SVV) task. Two rhesus monkeys were trained to align a light bar parallel to gravity and performed this task during roll tilts, centrifugation, and roll optokinetic stimulation. The monkeys accurately aligned the light bar with gravity during static roll tilts but also demonstrated small orientation-dependent misperceptions of the tilt angle analogous to those measured in humans. When the gravito-inertial force (GIF) rotated dynamically in the roll plane, SVV responses remained closely aligned with the GIF during roll tilt of the head (coplanar canal rotational cues present), lagged slightly behind the GIF during variable-radius centrifugation (no canal cues present), and shifted gradually during fixed-radius centrifugation (orthogonal yaw canal cues present). SVV responses also deviated away from the earth-vertical during roll optokinetic stimulation. These results demonstrate that rotational cues derived from the semicircular canals and visual system have prominent effects on psychophysical measurements of roll tilt in rhesus monkeys and therefore suggest that a central synthesis of graviceptive and rotational cues contributes to percepts of head orientation relative to gravity in non-human primates.

  8. Thermal and tilt effects on bearing characteristics of hydrostatic oil pad in rotary table

    Institute of Scientific and Technical Information of China (English)

    刘志峰; 湛承鹏; 程强; 赵永胜; 李小燕; 王义达

    2016-01-01

    Hydrostatic pads are key components of a constant flow compensation hydrostatic rotary table. The tilt and thermal effects due to the partial load, the manufacturing errors and the friction must be considered. However, designers are more likely inclined to ignore these effects. In this work, the coupled characteristics of the tilt and thermal effects are studied. A coupled mathematical model to calculate the bearing properties of the pads is built. This model takes into consideration of tilt and thermal effects and is used to solve the flow problem by the finite difference method. The characteristics of the oil pad, including, the recess pressures, the load carrying capacity and the damping coefficients, are obtained and the tilt and thermal effects are analyzed. It is observed that the tilt has a tremendous impact on the bearing characteristics of the hydrostatic pad. The recess pressure, the load carrying capacity and the stiffness are reduced by 50% and the pressure distribution and the temperature distribution of the oil film also change significantly. When the pads work under a tilt operation, a larger land width is better for its bearing properties. It is also observed that the thermal effect is significant and cannot be ignored.

  9. Fast and automatic identification of particle tilt pairs based on Delaunay triangulation.

    Science.gov (United States)

    Vilas, J L; Navas, J; Gómez-Blanco, J; de la Rosa-Trevín, J M; Melero, R; Peschiera, I; Ferlenghi, I; Cuenca, J; Marabini, R; Carazo, J M; Vargas, J; Sorzano, C O S

    2016-12-01

    Random conical tilt (RCT) and orthogonal tilt reconstruction (OTR) are two remarkable methods for reconstructing the three-dimensional structure of macromolecules at low resolution. These techniques use two images at two different sample tilts. One of the most demanding steps in these methods at the image processing level is to identify corresponding particles on both micrographs, and manual or semiautomatic matching methods are usually used. Here we present an approach to solve this bottleneck with a fully automatic method for assigning particle tilt pairs. This new algorithm behaves correctly with a variety of samples, covering the range from small to large macromolecules and from sparse to densely populated fields of view. It is also more rapid than previous approaches. The roots of the method lie in a Delaunay triangulation of the set of independently picked coordinates on both the untilted and tilted micrographs. These triangulations are then used to search an affine transformation between the untilted and tilted triangles. The affine transformation that maximizes the number of correspondences between the two micrographs defines the coordinate matching. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Numerical Simulations of Naturally Tilted, Retrogradely Precessing, Nodal Superhumping Accretion Disks

    CERN Document Server

    Montgomery, M M

    2012-01-01

    Accretion disks around black hole, neutron star, and white dwarf systems are thought to sometimes tilt, retrogradely precess, and produce hump-shaped modulations in light curves that have a period shorter than the orbital period. Although artificially rotating numerically simulated accretion disks out of the orbital plane and around the line of nodes generates these short-period superhumps and retrograde precession of the disk, no numerical code to date has been shown to produce a disk tilt naturally. In this work, we report the first naturally tilted disk in non-magnetic Cataclysmic Variables (CVs) using 3D Smoothed Particle Hydrodynamics (SPH). Our simulations show that after many hundreds of orbital periods, the disk has tilted on its own and this disk tilt is without the aid of radiation sources or magnetic fields. As the system orbits, the accretion stream strikes the bright spot (which is on the rim of the tilted disk) and flows over and under the disk on different flow paths. These different flow paths...

  11. Statistical and dynamical aspects in fission process: The rotational degrees of freedom

    Indian Academy of Sciences (India)

    Bency John

    2015-08-01

    In the final phases of fission process, there are fast collective rotational degrees of freedom, which can exert a force on the slower tilting rotational degree. Experimental observations that lead to this realization and theoretical studies that account for dynamics of the processes are discussed briefly. Supported by these studies, and by assuming a conditional equilibrium of the collective rotational modes at a pre-scission point, a new statistical model for fission fragment angular and spin distributions has been developed. This model gives a consistent description of the fragment angular and spin distributions for a wide variety of heavy- and light-ion-induced fission reactions.

  12. Rethinking the Bachelor Degree Course

    DEFF Research Database (Denmark)

    Toft, Anne Elisabeth; Gammelgaard Nielsen, Anders

    2011-01-01

    The text contains reflections on the background for rethinking the bachelor degree course at the Aarhus School of Architecture.......The text contains reflections on the background for rethinking the bachelor degree course at the Aarhus School of Architecture....

  13. Head-Down Tilt with Balanced Traction as a Model for Simulating Spinal Acclimation to Microgravity

    Science.gov (United States)

    Ballard, R. E.; Styf, J. R.; Watenpaugh, D. E.; Fechner, K.; Haruna, Y.; Kahan, N. J.; Hargens, A. R.

    1994-01-01

    Astronauts experience total body height increases of 4 to 7 cm in microgravity. Thus, stretching of the spinal cord, nerve roots, and muscular and ligamentous tissues may be responsible for the hyperreflexia, back pain, and muscular atrophy associated with exposure to microgravity. Axial compression of the spine makes 6 deg. head-down tilt (HDT) an unsuitable model for spinal acclimation to microgravity. However, this axial compression may be counteracted by balanced traction consisting of 10% body weight (sin 6 deg. = 0.1) applied to the legs. Six healthy male subjects underwent 3 days each of 60 HDT with balanced traction and horizontal bed rest (HBR), with a 2 week recovery period between treatments. Total body and spine length, lumbar disc height, back pain, erector spinae intramuscular pressure, and ankle joint torque were measured before, during and after each treatment. Total body and spine (processes of L5 - C7) lengths increased significantly more during HDT with balanced traction (22 +/- 8 mm and 25 +/- 8 mm, respectively) than during HBR (16 +/- 4 mm and 14 +/- 9 mm, respectively). Back and leg pain were significantly greater during HDT with balanced traction than during HBR. The distance between the lower end plate of L4 and the upper endplate of S1, as measured by sonography, increased significantly in both treatments to the same degree (2.9 +/- 1.9 mm, HDT with balanced traction; 3.3 +/- 1.5 mm, HBR). Intramuscular pressure of the erector spinae muscles and maximal ankle joint torque were unaltered with both models. While neither model increased height to the magnitude observed in microgravity, HDT with balanced traction may be a better model for simulating the body lengthening and back pain experienced in microgravity.

  14. Analysis of Heart Rate Variability Before and During Tilt Test in Patients with Cardioinhibitory Vasovagal Syncope

    Science.gov (United States)

    Miranda, Cláudia Madeira; da Silva, Rose Mary Ferreira Lisboa

    2016-01-01

    Background Cardioinhibitory vasovagal response is uncommon during the tilt test (TT). Heart rate variability (HRV) by use of spectral analysis can distinguish patients with that response. Objective To compare the HRV in patients with cardioinhibitory vasovagal syncope (case group - G1) with that in patients without syncope and with negative response to TT (control group - G2). Methods 64 patients were evaluated (mean age, 36.2 years; 35 men) and submitted to TT at 70 degrees, under digital Holter monitoring. The groups were paired for age and sex (G1, 40 patients; G2, 24). Results In G1, 21 patients had a type 2A response and 19 had type 2B, with mean TT duration of 20.4 minutes. There was a greater low frequency (LF) component (11,6 versus 4,5 ms2, p=0.001) and a lower low/high frequency ratio in the supine position (3,9 versus 4,5 ms2, p=0.008) in G1, with no difference during TT between the groups. Applying the receiver operating characteristic curve for cardioinhibitory response, the area under the curve was 0.74 for the LF component in the supine position (p = 0.001). The following were observed for the cutoff point of 0.35 ms(2) for the LF component: sensitivity, 97.4%; specificity, 83.3%; positive predictive value, 85.3%; negative predictive value, 96.9%; and positive likelihood ratio, 5.8. Conclusion HRV in the supine position allowed identifying patients with syncope and cardioinhibitory response with a high negative predictive value and likelihood ratio of 5.8.

  15. Cerebral haemodynamic response to acute intracranial hypertension induced by head-down tilt.

    Science.gov (United States)

    Bosone, Daniele; Ozturk, Vesile; Roatta, Silvestro; Cavallini, Anna; Tosi, Piera; Micieli, Giuseppe

    2004-01-01

    The aim of this study was to evaluate, in a context of general inhibition of the sympathetic nervous system, the cerebral haemodynamic response to -30 degrees head-down tilt (HDT), a manoeuvre that produces an increase in intracranial arterial pressure. Nineteen healthy subjects were studied according to the following protocol: 10 min lying in supine position, 10 min HDT, 10 min recovery. Inhibition of the sympathetic system was confirmed by the decrease in heart rate (-3.6 bpm) and arterial blood pressure (-5.9 mmHg, p<0.05) in the late phase of the test. Blood velocity and blood pusatility index initially increased (+3.2 cm s(-1) and +9% respectively, p<0.01) then returned towards baseline before the end of HDT, while the cerebrovascular resistance index (=arterial blood pressure/blood velocity) dropped significantly and remained below control level (-7%, p<0.01) throughout the test. The changes in both these indices were opposite to those reported in several sympathetic activation tests, such as the handgrip and cold pressor tests. Conversely, arterial pressure at cranial level increased during HDT (as it also does during sympathetic activation tests), due to the development of a hydrostatic pressure gradient between heart and brain levels. Therefore, the effects observed on the pulsatility and resistance indices are not secondary to the increase in intracranial arterial pressure. It is suggested that the changes in these cerebrovascular indices are mediated by a reduction of sympathetic tone that presumably involves the cerebral as well as the peripheral vascular bed.

  16. Foundation Degrees: A Risky Business?

    Science.gov (United States)

    Rowley, Jennifer

    2005-01-01

    Purpose: Foundation degrees, the new proposal for sub-degree vocational education in the UK, are characterised by innovation both in their design (curriculum, teaching, learning and assessment) and in the marketplace for which they are designed. This article argues that the development and delivery of foundation degrees carry a high level of risk,…

  17. Bielschowsky head-tilt test-I. Ocular counterrolling and Bielschowsky head-tilt test in 23 cases of superior oblique palsy

    NARCIS (Netherlands)

    H.J. Simonsz (Huib); R.A. Crone; J.W.C. Meer (Jolanda); C.F. Merckel-Timmer; A.M. van Mourik-Noordenbos

    1985-01-01

    textabstractWe have measured the amplitude of ocular counterrolling (OCR) and the change in vertical deviation in the Bielschowsky head-tilt test (BHT) in 23 cases of unilateral superior oblique palsy. OCR was measured with a photographical method, using limbal, conjunctival vessels as landmarks.

  18. Bielschowsky head-tilt test-I. Ocular counterrolling and Bielschowsky head-tilt test in 23 cases of superior oblique palsy

    NARCIS (Netherlands)

    H.J. Simonsz (Huib); R.A. Crone; J.W.C. Meer (Jolanda); C.F. Merckel-Timmer; A.M. van Mourik-Noordenbos

    1985-01-01

    textabstractWe have measured the amplitude of ocular counterrolling (OCR) and the change in vertical deviation in the Bielschowsky head-tilt test (BHT) in 23 cases of unilateral superior oblique palsy. OCR was measured with a photographical method, using limbal, conjunctival vessels as landmarks. Av

  19. Design and Analysis of Delta Wing Tilt Rotor UAV

    Directory of Open Access Journals (Sweden)

    S.Ravikanth

    2015-07-01

    Full Text Available A tilt rotor is an aircraft of a special kind, which possesses the characteristics of a helicopter and a fixed-wing airplane. However, there are a great number of important technical problems waiting for settlements. Of them, the flight control system might be a critical one. A tiltrotor aircraft comprising a pair of contra-rotating co-axial tiltable rotors on the longitudinal center line of the aircraft. The rotors may be tiltable sequentially and independently. They may be moveable between a lift position and a flight position in front of or behind the fuselage.In this paper we present a project aimed for the designing of a small scale Unmanned Aerial Vehicle (UAV with Tiltrotor configuration (that uses two rotating rotors. he current paper describes the adopted design methodology, the mathematical and computational models created to represent the UAV, the physical components that constitute the UAV, and the results obtained so far. An unmanned aerial vehicle (UAV, also known as a remotely piloted aircraft (RPA or unmanned aircraft, is a machine which functions either by the remote control of a navigator or pilot or autonomously. A UAV is defined as a powered, aerial vehicle that does not carry a human operator, uses aerodynamic forces to provide vehicle lift, can fly autonomously or be piloted remotely, can be expendable or recoverable, and can carry payload.India‘s requirement of these unmanned aerial vehicles (UAV has become prior need for fighting in the northeast, against threat of terrorism, tension along the Pakistan border and its emerging role as a regional naval power and subsequent need for surveillance. The military wants to acquire at least 1,500 unmanned systems in the next 3-4 years, ranging from man-portable drones to high-altitude, long-endurance (HALE vehicles.Indian military is using Israeli-built UAVs such as the Heron, Searcher Mk II and Harop from Israel Aerospace Industries (IAI. Till date India has mostly deployed

  20. Degree-degree correlations in random graphs with heavy-tailed degrees

    NARCIS (Netherlands)

    Litvak, Nelli; van der Hofstad, Remco

    2012-01-01

    We investigate degree-degree correlations for scale-free graph sequences. The main conclusion of this paper is that the assortativity coefficient is not the appropriate way to describe degree-dependences in scale-free random graphs. Indeed, we study the infinite volume limit of the assortativity