WorldWideScience

Sample records for degrees digital fundus

  1. Screening for diabetic retinopathy in rural area using single-field, digital fundus images.

    Science.gov (United States)

    Ruamviboonsuk, Paisan; Wongcumchang, Nattapon; Surawongsin, Pattamaporn; Panyawatananukul, Ekchai; Tiensuwan, Montip

    2005-02-01

    To evaluate the practicability of using single-field, 2.3 million-pixel, digital fundus images for screening of diabetic retinopathy in rural areas. All diabetic patients who regularly attended the diabetic clinic at Kabcheang Community Hospital, located at 15 kilometers from the Thailand-Cambodia border, were appointed to the hospital for a 3-day diabetic retinopathy screening programme. The fundi of all patients were captured in single-field, 45 degrees, 2.3 million-pixel images using nonmydriatic digital fundus camera and then sent to a reading center in Bangkok. The fundi were also examined through dilated pupils by a retinal specialist at this hospital. The grading of diabetic retinopathy from two methods was compared for an exact agreement. The average duration of single digital fundus image capture was 2 minutes. The average file size of each image was 750 kilobytes. The average duration of single image transmission to a reading center in Bangkok via satellite was 3 minutes; via a conventional telephone line was 8 minutes. Of all 150 patients, 130 were assessed for an agreement between dilated fundus examination and digital fundus images in diagnosis of diabetic retinopathy. The exact agreement was 0.87, the weighted kappa statistics was 0.74. The sensitivity of digital fundus images in detecting diabetic retinopathy was 80%, the specificity was 96%. For diabetic macular edema the exact agreement was 0.97, the weighted kappa was 0.43, the sensitivity was 43%, and the specificity was 100%. The image capture of the nonmydriatic digital fundus camera is suitable for screening of diabetic retinopathy and single-field digital fundus images are potentially acceptable tools for the screening. The real-time image transmission via telephone lines to remote reading center, however, may not be practical for routine diabetic retinopathy screening in rural areas.

  2. The sensitivity and specificity of one field non-mydriatic digital fundus photography for DR screening

    Directory of Open Access Journals (Sweden)

    Bin-Bin Li

    2013-07-01

    Full Text Available AIM:To evaluate the sensitivity and specificity of one-field non-mydriatic digital fundus photography and direct ophthalmoscopy for diabetic retinopathy(DRscreening, compared with fundus fluorescein angiography( FFA .METHODS:All 93 patients of type 1 or 2 diabetic who have underwent one-field non-mydriatic digital fundus photography, and direct ophthalmoscopy with dilation of their pupils, and FFA by ophthalmologists. The sensitivity and specificity of one-field non-mydriatic digital fundus photography and direct ophthalmoscopy were calculated respectively, compared with FFA.RESULTS: The sensitivity and specificity of one-field non-mydriatic digital fundus photography for detection of any DR were 80.4% and 94.7%; The sensitivity and specificity of direct ophthalmoscopy for detection of any DR were 64.2% and 84.2%; After the standard for referable DR being lowered down to the moderate non-proliferative diabetic retinopathy(M-NPDR, the sensitivity and specificity of non-mydriatic digital fundus photography for detection were 88.9% and 98.4%, the sensitivity and specificity of direct ophthalmoscopy for detection were 71.5% and 96.7%.CONCLUSION: One-field non-mydriatic digital fundus photography is an effective method for DR screening.

  3. Automatic Microaneurysm Detection and Characterization Through Digital Color Fundus Images

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Charles; Veras, Rodrigo; Ramalho, Geraldo; Medeiros, Fatima; Ushizima, Daniela

    2008-08-29

    Ocular fundus images can provide information about retinal, ophthalmic, and even systemic diseases such as diabetes. Microaneurysms (MAs) are the earliest sign of Diabetic Retinopathy, a frequently observed complication in both type 1 and type 2 diabetes. Robust detection of MAs in digital color fundus images is critical in the development of automated screening systems for this kind of disease. Automatic grading of these images is being considered by health boards so that the human grading task is reduced. In this paper we describe segmentation and the feature extraction methods for candidate MAs detection.We show that the candidate MAs detected with the methodology have been successfully classified by a MLP neural network (correct classification of 84percent).

  4. Image quality characteristics of a novel colour scanning digital ophthalmoscope (SDO) compared with fundus photography.

    Science.gov (United States)

    Strauss, Rupert W; Krieglstein, Tina R; Priglinger, Siegfried G; Reis, Werner; Ulbig, Michael W; Kampik, Anselm; Neubauer, Aljoscha S

    2007-11-01

    To establish a set of quality parameters for grading image quality and apply those to evaluate the fundus image quality obtained by a new scanning digital ophthalmoscope (SDO) compared with standard slide photography. On visual analogue scales a total of eight image characteristics were defined: overall quality, contrast, colour brilliance, focus (sharpness), resolution and details, noise, artefacts and validity of clinical assessment. Grading was repeated after 4 months to assess repeatability. Fundus images of 23 patients imaged digitally by SDO and by Zeiss 450FF fundus camera using Kodak film were graded side-by-side by three graders. Lens opacity was quantified with the Interzeag Lens Opacity Meter 701. For all of the eight scales of image quality, good repeatability within the graders (mean Kendall's W 0.69) was obtained after 4 months. Inter-grader agreement ranged between 0.31 and 0.66. Despite the SDO's limited nominal image resolution of 720 x 576 pixels, the Zeiss FF 450 camera performed better in only two of the subscales - noise (p = 0.001) and artefacts (p = 0.01). Lens opacities significantly influenced only the two subscales 'resolution' and 'details', which deteriorated with increasing media opacities for both imaging systems. Distinct scales to grade image characteristics of different origin were developed and validated. Overall SDO digital imaging was found to provide fundus pictures of a similarly high level of quality as expert photography on slides.

  5. Retinopathy online challenge: automatic detection of microaneurysms in digital color fundus photographs.

    NARCIS (Netherlands)

    Niemeijer, M.; Ginneken, B. van; Cree, M.J.; Mizutani, A.; Quellec, G.; Sanchez, C.I.; Zhang, B.; Hornero, R.; Lamard, M.; Muramatsu, C.; Wu, X.; Cazuguel, G.; You, J.; Mayo, A.; Li, Q.; Hatanaka, Y.; Cochener, B.; Roux, C.; Karray, F.; Garcia, M.; Fujita, H.; Abramoff, M.D.

    2010-01-01

    The detection of microaneurysms in digital color fundus photographs is a critical first step in automated screening for diabetic retinopathy (DR), a common complication of diabetes. To accomplish this detection numerous methods have been published in the past but none of these was compared with each

  6. Diabetic Retinopathy Screening Ratio Is Improved When Using a Digital, Nonmydriatic Fundus Camera Onsite in a Diabetes Outpatient Clinic

    Directory of Open Access Journals (Sweden)

    Pia Roser

    2016-01-01

    Full Text Available Objective. To evaluate the effect of onsite screening with a nonmydriatic, digital fundus camera for diabetic retinopathy (DR at a diabetes outpatient clinic. Research Design and Methods. This cross-sectional study included 502 patients, 112 with type 1 and 390 with type 2 diabetes. Patients attended screenings for microvascular complications, including diabetic nephropathy (DN, diabetic polyneuropathy (DP, and DR. Single-field retinal imaging with a digital, nonmydriatic fundus camera was used to assess DR. Prevalence and incidence of microvascular complications were analyzed and the ratio of newly diagnosed to preexisting complications for all entities was calculated in order to differentiate natural progress from missed DRs. Results. For both types of diabetes, prevalence of DR was 25.0% (n=126 and incidence 6.4% (n=32 (T1DM versus T2DM: prevalence: 35.7% versus 22.1%, incidence 5.4% versus 6.7%. 25.4% of all DRs were newly diagnosed. Furthermore, the ratio of newly diagnosed to preexisting DR was higher than those for DN (p=0.12 and DP (p=0.03 representing at least 13 patients with missed DR. Conclusions. The results indicate that implementing nonmydriatic, digital fundus imaging in a diabetes outpatient clinic can contribute to improved early diagnosis of diabetic retinopathy.

  7. Determining degree of optic nerve edema from color fundus photography

    Science.gov (United States)

    Agne, Jason; Wang, Jui-Kai; Kardon, Randy H.; Garvin, Mona K.

    2015-03-01

    Swelling of the optic nerve head (ONH) is subjectively assessed by clinicians using the Frisén scale. It is believed that a direct measurement of the ONH volume would serve as a better representation of the swelling. However, a direct measurement requires optic nerve imaging with spectral domain optical coherence tomography (SD-OCT) and 3D segmentation of the resulting images, which is not always available during clinical evaluation. Furthermore, telemedical imaging of the eye at remote locations is more feasible with non-mydriatic fundus cameras which are less costly than OCT imagers. Therefore, there is a critical need to develop a more quantitative analysis of optic nerve swelling on a continuous scale, similar to SD-OCT. Here, we select features from more commonly available 2D fundus images and use them to predict ONH volume. Twenty-six features were extracted from each of 48 color fundus images. The features include attributes of the blood vessels, optic nerve head, and peripapillary retina areas. These features were used in a regression analysis to predict ONH volume, as computed by a segmentation of the SD-OCT image. The results of the regression analysis yielded a mean square error of 2.43 mm3 and a correlation coefficient between computed and predicted volumes of R = 0:771, which suggests that ONH volume may be predicted from fundus features alone.

  8. Image analysis of ocular fundus for retinopathy characterization

    Energy Technology Data Exchange (ETDEWEB)

    Ushizima, Daniela; Cuadros, Jorge

    2010-02-05

    Automated analysis of ocular fundus images is a common procedure in countries as England, including both nonemergency examination and retinal screening of patients with diabetes mellitus. This involves digital image capture and transmission of the images to a digital reading center for evaluation and treatment referral. In collaboration with the Optometry Department, University of California, Berkeley, we have tested computer vision algorithms to segment vessels and lesions in ground-truth data (DRIVE database) and hundreds of images of non-macular centric and nonuniform illumination views of the eye fundus from EyePACS program. Methods under investigation involve mathematical morphology (Figure 1) for image enhancement and pattern matching. Recently, we have focused in more efficient techniques to model the ocular fundus vasculature (Figure 2), using deformable contours. Preliminary results show accurate segmentation of vessels and high level of true-positive microaneurysms.

  9. Automated Detection and Differentiation of Drusen, Exudates, and Cotton-Wool Spots in Digital Color Fundus Photographs for Diabetic Retinopathy Diagnosis

    NARCIS (Netherlands)

    Niemeijer, M.; van Ginneken, B.; Russel, S.R.; Suttorp-Schulten, M.S.A.; Abràmoff, M.D.

    2007-01-01

    purpose. To describe and evaluate a machine learning-based, automated system to detect exudates and cotton-wool spots in digital color fundus photographs and differentiate them from drusen, for early diagnosis of diabetic retinopathy. methods. Three hundred retinal images from one eye of 300

  10. Quantitative evaluation of papilledema from stereoscopic color fundus photographs.

    Science.gov (United States)

    Tang, Li; Kardon, Randy H; Wang, Jui-Kai; Garvin, Mona K; Lee, Kyungmoo; Abràmoff, Michael D

    2012-07-03

    To derive a computerized measurement of optic disc volume from digital stereoscopic fundus photographs for the purpose of diagnosing and managing papilledema. Twenty-nine pairs of stereoscopic fundus photographs and optic nerve head (ONH) centered spectral domain optical coherence tomography (SD-OCT) scans were obtained at the same visit in 15 patients with papilledema. Some patients were imaged at multiple visits in order to assess their changes. Three-dimensional shape of the ONH was estimated from stereo fundus photographs using an automated multi-scale stereo correspondence algorithm. We assessed the correlation of the stereo volume measurements with the SD-OCT volume measurements quantitatively, in terms of volume of retinal surface elevation above a reference plane and also to expert grading of papilledema from digital fundus photographs using the Frisén grading scale. The volumetric measurements of retinal surface elevation estimated from stereo fundus photographs and OCT scans were positively correlated (correlation coefficient r(2) = 0.60; P photographs compares favorably with that from OCT scans and with expert grading of papilledema severity. Stereoscopic color imaging of the ONH combined with a method of automated shape reconstruction is a low-cost alternative to SD-OCT scans that has potential for a more cost-effective diagnosis and management of papilledema in a telemedical setting. An automated three-dimensional image analysis method was validated that quantifies the retinal surface topography with an imaging modality that has lacked prior objective assessment.

  11. Diagnosing and ranking retinopathy disease level using diabetic fundus image recuperation approach.

    Science.gov (United States)

    Somasundaram, K; Rajendran, P Alli

    2015-01-01

    Retinal fundus images are widely used in diagnosing different types of eye diseases. The existing methods such as Feature Based Macular Edema Detection (FMED) and Optimally Adjusted Morphological Operator (OAMO) effectively detected the presence of exudation in fundus images and identified the true positive ratio of exudates detection, respectively. These mechanically detected exudates did not include more detailed feature selection technique to the system for detection of diabetic retinopathy. To categorize the exudates, Diabetic Fundus Image Recuperation (DFIR) method based on sliding window approach is developed in this work to select the features of optic cup in digital retinal fundus images. The DFIR feature selection uses collection of sliding windows with varying range to obtain the features based on the histogram value using Group Sparsity Nonoverlapping Function. Using support vector model in the second phase, the DFIR method based on Spiral Basis Function effectively ranks the diabetic retinopathy disease level. The ranking of disease level on each candidate set provides a much promising result for developing practically automated and assisted diabetic retinopathy diagnosis system. Experimental work on digital fundus images using the DFIR method performs research on the factors such as sensitivity, ranking efficiency, and feature selection time.

  12. Interoperative fundus image and report sharing in compliance with integrating the healthcare enterprise conformance and web access to digital imaging and communication in medicine persistent object protocol.

    Science.gov (United States)

    Wu, Hui-Qun; Lv, Zheng-Min; Geng, Xing-Yun; Jiang, Kui; Tang, Le-Min; Zhou, Guo-Min; Dong, Jian-Cheng

    2013-01-01

    To address issues in interoperability between different fundus image systems, we proposed a web eye-picture archiving and communication system (PACS) framework in conformance with digital imaging and communication in medicine (DICOM) and health level 7 (HL7) protocol to realize fundus images and reports sharing and communication through internet. Firstly, a telemedicine-based eye care work flow was established based on integrating the healthcare enterprise (IHE) Eye Care technical framework. Then, a browser/server architecture eye-PACS system was established in conformance with the web access to DICOM persistent object (WADO) protocol, which contains three tiers. In any client system installed with web browser, clinicians could log in the eye-PACS to observe fundus images and reports. Multipurpose internet mail extensions (MIME) type of a structured report is saved as pdf/html with reference link to relevant fundus image using the WADO syntax could provide enough information for clinicians. Some functions provided by open-source Oviyam could be used to query, zoom, move, measure, view DICOM fundus images. Such web eye-PACS in compliance to WADO protocol could be used to store and communicate fundus images and reports, therefore is of great significance for teleophthalmology.

  13. Diagnosing and Ranking Retinopathy Disease Level Using Diabetic Fundus Image Recuperation Approach

    Directory of Open Access Journals (Sweden)

    K. Somasundaram

    2015-01-01

    Full Text Available Retinal fundus images are widely used in diagnosing different types of eye diseases. The existing methods such as Feature Based Macular Edema Detection (FMED and Optimally Adjusted Morphological Operator (OAMO effectively detected the presence of exudation in fundus images and identified the true positive ratio of exudates detection, respectively. These mechanically detected exudates did not include more detailed feature selection technique to the system for detection of diabetic retinopathy. To categorize the exudates, Diabetic Fundus Image Recuperation (DFIR method based on sliding window approach is developed in this work to select the features of optic cup in digital retinal fundus images. The DFIR feature selection uses collection of sliding windows with varying range to obtain the features based on the histogram value using Group Sparsity Nonoverlapping Function. Using support vector model in the second phase, the DFIR method based on Spiral Basis Function effectively ranks the diabetic retinopathy disease level. The ranking of disease level on each candidate set provides a much promising result for developing practically automated and assisted diabetic retinopathy diagnosis system. Experimental work on digital fundus images using the DFIR method performs research on the factors such as sensitivity, ranking efficiency, and feature selection time.

  14. Strategies of digital fundus photography for screening diabetic retinopathy in a diabetic population in urban China.

    Science.gov (United States)

    Ding, Jiyuan; Zou, Yanhong; Liu, Ningpu; Jiang, Li; Ren, Xuetao; Jia, Wei; Snellingen, Torkel; Chongsuvivatwong, Virasakdi; Liu, Xipu

    2012-12-01

    To evaluate the effect of mydriasis and different field strategies on technical failure, probability to refer diabetic retinopathy (DR, sensitivity) and probability not to refer patients without DR (specificity) of digital photography in screening with a fundus camera. A total of 531 patients with diabetes underwent fundus photography with cross-combinations of mydriasis/nonmydriasis and single-field/two-field strategies, followed by slit lamp biomicroscopic examination by a trained ophthalmologist. Fundus photographs were graded independently by another experienced ophthalmologist. Calculations were first based on cases with non-gradable images treated as being referred and then with them excluded. Percentages of DR and referable DR in this patient cohort were 22.4% and 7.7%, respectively, based on slit lamp biomicroscopic examination. Mydriasis significantly reduced the technical failure rate from 27.1% to 8.3% under a single-field strategy, and from 28.2% to 8.9% under a two-field strategy. As compared to the single-field strategy, the two-field strategy increased sensitivity from 75.6% to 87.8% without mydriasis and from 73.2% to 90.2% with mydriasis. Mydriasis increased specificity from 68.8% to 84.3% in the single-field strategy and from 64.7% to 81.6% in the two-field strategy. Had the subjects with non-gradable images been excluded, the two-field strategy without mydriasis reported sensitivity of 85.7% and specificity of 91.6%. Both mydriasis and the two-field strategy are useful in photographic screening tests. Technical failure should be taken into consideration when screening strategies for DR are determined.

  15. Inter-Rater Reliability of Cyclotorsion Measurements Using Fundus Photography.

    Science.gov (United States)

    Dysli, Muriel; Kanku, Madeleine; Traber, Ghislaine L

    2018-04-01

    The foveo-papillary angle (FPA) on fundus photographs is the accepted standard for the measurement of ocular cyclotorsion. We assessed the inter-rater reliability of this method in healthy subjects and in patients with trochlear nerve palsies. In this methodological study, fundus photographs of healthy subjects and of patients with trochlear nerve palsies were made with a fundus camera (Zeiss Fundus Camera FF 450 plus, Jena, Germany). Three independent observers measured the FPA on the fundus photographs of all subjects in synedra View (synedra View 16, Version 16.0.0.11, Innsbruck, Austria). One hundred and four eyes of 52 subjects (26 healthy controls and 26 patients) were assessed. The mean FPA of the healthy controls was 5.80 degrees (°) [± 0.44 standard error of the mean (SEM)] compared to 11.55° (± 0.80 SEM) for patients with trochlear nerve palsies. The inter-rater reliability of all measured FPAs showed an intraclass correlation coefficient (ICC) of 0.98 (95% CI 0.97 - 0.98). The inter-rater reliability of objective cyclotorsion measurements using fundus photographs was very high. Georg Thieme Verlag KG Stuttgart · New York.

  16. The diagnostic accuracy of single- and five-field fundus photography in diabetic retinopathy screening by primary care physicians.

    Science.gov (United States)

    Srihatrai, Parinya; Hlowchitsieng, Thanita

    2018-01-01

    The aim is to evaluate the diagnostic accuracy of digital fundus photography in diabetic retinopathy (DR) screening at a single university hospital. This was a cross-sectional hospital-based study. One hundred and ninety-eight diabetic patients were recruited for comprehensive eye examination by two ophthalmologists. Five-field fundus photographs were taken with a digital, nonmydriatic fundus camera, and trained primary care physicians then graded the severity of DR present by single-field 45° and five-field fundus photography. Sensitivity and specificity of DR grading were reported using the findings from the ophthalmologists' examinations as a gold standard. When fundus photographs of the participants' 363 eyes were analyzed for the presence of DR, there was substantial agreement between the two primary care physicians, κ = 0.6226 for single-field and 0.6939 for five-field photograph interpretation. The sensitivity and specificity of DR detection with single-field photographs were 70.7% (95% Confidence interval [CI]; 60.2%-79.7%) and 99.3% (95% CI; 97.4%-99.9%), respectively. Sensitivity and specificity for five-field photographs were 84.5% (95% CI; 75.8%-91.1%) and 98.6% (95% CI; 96.5%-99.6%), respectively. The receiver operating characteristic was 0.85 (0.80-0.90) for single-field photographs and 0.92 (0.88-0.95) for five-field photographs. The sensitivity and specificity of fundus photographs for DR detection by primary care physicians were acceptable. Single- and five-field digital fundus photography each represent a convenient screening tool with acceptable accuracy.

  17. Detection of Fundus Lesions Using Classifier Selection

    Science.gov (United States)

    Nagayoshi, Hiroto; Hiramatsu, Yoshitaka; Sako, Hiroshi; Himaga, Mitsutoshi; Kato, Satoshi

    A system for detecting fundus lesions caused by diabetic retinopathy from fundus images is being developed. The system can screen the images in advance in order to reduce the inspection workload on doctors. One of the difficulties that must be addressed in completing this system is how to remove false positives (which tend to arise near blood vessels) without decreasing the detection rate of lesions in other areas. To overcome this difficulty, we developed classifier selection according to the position of a candidate lesion, and we introduced new features that can distinguish true lesions from false positives. A system incorporating classifier selection and these new features was tested in experiments using 55 fundus images with some lesions and 223 images without lesions. The results of the experiments confirm the effectiveness of the proposed system, namely, degrees of sensitivity and specificity of 98% and 81%, respectively.

  18. Comparison of digital color fundus imaging and fluorescein angiographic findings for the early detection of diabetic retinopathy in young type 1 diabetic patients.

    Science.gov (United States)

    Kapsala, Z; Anastasakis, A; Mamoulakis, D; Maniadaki, I; Tsilimbaris, M

    2018-01-01

    To compare the findings from digital 7-field color fundus (CF) photography and fundus fluorescein angiography (FFA) in young patients with diabetes mellitus (DM) type 1 without known diabetic retinopathy. In this prospective, observational cohort study, 54 type 1 diabetic patients were recruited. Participants had been diagnosed with diabetes mellitus (DM) for at least 6 years, had Best Corrected Visual Acuity of 20/25 or better and did not have any known retinal pathology. One hundred and seven eyes were analyzed. All patients underwent a complete ophthalmic examination in the Retina Service of a University Eye Clinic including digital CF imaging and FFA. The mean age of the patients was 18.6 years. Mean duration of DM was 11.3 years, and mean haemoglobin A1c (HbA1c) level was 8.6%. Of the 107 eyes, 8 eyes (7.5%) showed microvascular abnormalities on CF images, while FFA images revealed changes in 26 eyes (24.3%). Hence, 18 of the 26 eyes showing abnormalities on FFA did not show any abnormalities on CF images. Mean DM duration in the patient group with detectable microvascular changes was found to be significantly higher compared to patients without changes, while no difference in HbA1c levels, serum lipid levels or blood pressure was observed. Comparison of digital CF and FFA findings for the detection of diabetic microvascular changes in type 1 diabetic patients showed that FFA reveals more information about retinal vascular pathology for early detection of diabetic retinopathy. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Unique identification code for medical fundus images using blood vessel pattern for tele-ophthalmology applications.

    Science.gov (United States)

    Singh, Anushikha; Dutta, Malay Kishore; Sharma, Dilip Kumar

    2016-10-01

    Identification of fundus images during transmission and storage in database for tele-ophthalmology applications is an important issue in modern era. The proposed work presents a novel accurate method for generation of unique identification code for identification of fundus images for tele-ophthalmology applications and storage in databases. Unlike existing methods of steganography and watermarking, this method does not tamper the medical image as nothing is embedded in this approach and there is no loss of medical information. Strategic combination of unique blood vessel pattern and patient ID is considered for generation of unique identification code for the digital fundus images. Segmented blood vessel pattern near the optic disc is strategically combined with patient ID for generation of a unique identification code for the image. The proposed method of medical image identification is tested on the publically available DRIVE and MESSIDOR database of fundus image and results are encouraging. Experimental results indicate the uniqueness of identification code and lossless recovery of patient identity from unique identification code for integrity verification of fundus images. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Smartphone Fundus Photography.

    Science.gov (United States)

    Nazari Khanamiri, Hossein; Nakatsuka, Austin; El-Annan, Jaafar

    2017-07-06

    Smartphone fundus photography is a simple technique to obtain ocular fundus pictures using a smartphone camera and a conventional handheld indirect ophthalmoscopy lens. This technique is indispensable when picture documentation of optic nerve, retina, and retinal vessels is necessary but a fundus camera is not available. The main advantage of this technique is the widespread availability of smartphones that allows documentation of macula and optic nerve changes in many settings that was not previously possible. Following the well-defined steps detailed here, such as proper alignment of the phone camera, handheld lens, and the patient's pupil, is the key for obtaining a clear retina picture with no interfering light reflections and aberrations. In this paper, the optical principles of indirect ophthalmoscopy and fundus photography will be reviewed first. Then, the step-by-step method to record a good quality retinal image using a smartphone will be explained.

  1. Optic Disc Detection from Fundus Photography via Best-Buddies Similarity

    Directory of Open Access Journals (Sweden)

    Kangning Hou

    2018-05-01

    Full Text Available Robust and effective optic disc (OD detection is a necessary processing step in the research work of the automatic analysis of fundus images. In this paper, we propose a novel and robust method for the automated detection of ODs from fundus photographs. It is essentially carried out by performing template matching using the Best-Buddies Similarity (BBS measure between the hand-marked OD region and the small parts of target images. For well characterizing the local spatial information of fundus images, a gradient constraint term was introduced for computing the BBS measurement. The performance of the proposed method is validated with Digital Retinal Images for Vessel Extraction (DRIVE and Standard Diabetic Retinopathy Database Calibration Level 1 (DIARETDB1 databases, and quantitative results were obtained. Success rates/error distances of 100%/10.4 pixel and of 97.7%/12.9 pixel, respectively, were achieved. The algorithm has been tested and compared with other commonly used methods, and the results show that the proposed method shows superior performance.

  2. Clinical significance of non-mydriatic fundus photography in screening for preschool children ocular fundus disease

    Directory of Open Access Journals (Sweden)

    Jun Luo

    2014-06-01

    Full Text Available AIM: To observe the incidence of ocular fundus disease in preschool children examined by non-mydriatic fundus camera and evaluate its effectiveness compared with direct inspection shadow mirror. METHODS: Three thousand eight hundred and ninety-six preschool children from April 2012 to October 2013 were examined by Topcon TRC-NW300 color fluorescence fundus camera and direct inspection shadow mirror, and images were saved immediately. RESULTS: Detection rate of non-mydriatic fundus photography was higher than that of direct inspection shadow mirror. In 3 896 cases, 41 eyes were detected abnormal fundus accounting for 1.05%. The retinal myelinated nerve fibers, morning glory syndrome, retinitis pigmentosa, congenital retinoschisis were common, accounted for 24.39%, 21.95%, 14.63%, 12.20% respectively. The children eye diseases were often accompanied by abnormal vision(68.30%, ametropia(63.41%, strabismus(19.51%.CONCLUSION: Non-mydriatic fundus photography is a mydriatic method without medicine, so it is easy for preschool children to accept. Image results could directly display the fundus lesions. It shows important significance in the screening for preschool children eye diseases.

  3. Textureless Macula Swelling Detection with Multiple Retinal Fundus Images

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Meriaudeau, Fabrice [ORNL; Karnowski, Thomas Paul [ORNL; Tobin Jr, Kenneth William [ORNL; Grisan, Enrico [University of Padua, Padua, Italy; Favaro, Paolo [Heriot-Watt University, Edinburgh; Ruggeri, Alfredo [University of Padua, Padua, Italy; Chaum, Edward [University of Tennessee, Knoxville (UTK)

    2010-01-01

    Retinal fundus images acquired with non-mydriatic digital fundus cameras are a versatile tool for the diagnosis of various retinal diseases. Because of the ease of use of newer camera models and their relatively low cost, these cameras can be employed by operators with limited training for telemedicine or Point-of-Care applications. We propose a novel technique that uses uncalibrated multiple-view fundus images to analyse the swelling of the macula. This innovation enables the detection and quantitative measurement of swollen areas by remote ophthalmologists. This capability is not available with a single image and prone to error with stereo fundus cameras. We also present automatic algorithms to measure features from the reconstructed image which are useful in Point-of-Care automated diagnosis of early macular edema, e.g., before the appearance of exudation. The technique presented is divided into three parts: first, a preprocessing technique simultaneously enhances the dark microstructures of the macula and equalises the image; second, all available views are registered using non-morphological sparse features; finally, a dense pyramidal optical flow is calculated for all the images and statistically combined to build a naiveheight- map of the macula. Results are presented on three sets of synthetic images and two sets of real world images. These preliminary tests show the ability to infer a minimum swelling of 300 microns and to correlate the reconstruction with the swollen location.

  4. Automatic segmentation of blood vessels from retinal fundus images ...

    Indian Academy of Sciences (India)

    The retinal blood vessels were segmented through color space conversion and color channel .... Retinal blood vessel segmentation was also attempted through multi-scale operators. A few works in this ... fundus camera at 35 degrees field of view. The image ... vessel segmentation is available from two human observers.

  5. Fundus Photography in the 21st Century--A Review of Recent Technological Advances and Their Implications for Worldwide Healthcare.

    Science.gov (United States)

    Panwar, Nishtha; Huang, Philemon; Lee, Jiaying; Keane, Pearse A; Chuan, Tjin Swee; Richhariya, Ashutosh; Teoh, Stephen; Lim, Tock Han; Agrawal, Rupesh

    2016-03-01

    The introduction of fundus photography has impacted retinal imaging and retinal screening programs significantly. Fundus cameras play a vital role in addressing the cause of preventive blindness. More attention is being turned to developing countries, where infrastructure and access to healthcare are limited. One of the major limitations for tele-ophthalmology is restricted access to the office-based fundus camera. Recent advances in access to telecommunications coupled with introduction of portable cameras and smartphone-based fundus imaging systems have resulted in an exponential surge in available technologies for portable fundus photography. Retinal cameras in the near future would have to cater to these needs by featuring a low-cost, portable design with automated controls and digitalized images with Web-based transfer. In this review, we aim to highlight the advances of fundus photography for retinal screening as well as discuss the advantages, disadvantages, and implications of the various technologies that are currently available.

  6. Fundus Photography in the 21st Century—A Review of Recent Technological Advances and Their Implications for Worldwide Healthcare

    Science.gov (United States)

    Panwar, Nishtha; Huang, Philemon; Lee, Jiaying; Keane, Pearse A.; Chuan, Tjin Swee; Richhariya, Ashutosh; Teoh, Stephen; Lim, Tock Han

    2016-01-01

    Abstract Background: The introduction of fundus photography has impacted retinal imaging and retinal screening programs significantly. Literature Review: Fundus cameras play a vital role in addressing the cause of preventive blindness. More attention is being turned to developing countries, where infrastructure and access to healthcare are limited. One of the major limitations for tele-ophthalmology is restricted access to the office-based fundus camera. Results: Recent advances in access to telecommunications coupled with introduction of portable cameras and smartphone-based fundus imaging systems have resulted in an exponential surge in available technologies for portable fundus photography. Retinal cameras in the near future would have to cater to these needs by featuring a low-cost, portable design with automated controls and digitalized images with Web-based transfer. Conclusions: In this review, we aim to highlight the advances of fundus photography for retinal screening as well as discuss the advantages, disadvantages, and implications of the various technologies that are currently available. PMID:26308281

  7. Digital fundus image grading with the non-mydriatic Visucam(PRO NM) versus the FF450(plus) camera in diabetic retinopathy.

    Science.gov (United States)

    Neubauer, Aljoscha S; Rothschuh, Antje; Ulbig, Michael W; Blum, Marcus

    2008-03-01

    Grading diabetic retinopathy in clinical trials is frequently based on 7-field stereo photography of the fundus in diagnostic mydriasis. In terms of image quality, the FF450(plus) camera (Carl Zeiss Meditec AG, Jena, Germany) defines a high-quality reference. The aim of the study was to investigate if the fully digital fundus camera Visucam(PRO NM) could serve as an alternative in clinical trials requiring 7-field stereo photography. A total of 128 eyes of diabetes patients were enrolled in the randomized, controlled, prospective trial. Seven-field stereo photography was performed with the Visucam(PRO NM) and the FF450(plus) camera, in random order, both in diagnostic mydriasis. The resulting 256 image sets from the two camera systems were graded for retinopathy levels and image quality (on a scale of 1-5); both were anonymized and blinded to the image source. On FF450(plus) stereoscopic imaging, 20% of the patients had no or mild diabetic retinopathy (ETDRS level cameras regarding retinopathy levels (kappa 0.87) and macular oedema (kappa 0.80). In diagnostic mydriasis the image quality of the Visucam was graded slightly as better than that of the FF450(plus) (2.20 versus 2.41; p camera for applications and clinical trials requiring 7-field stereo photography.

  8. Application of smart phone and supporting set for fundus imaging in primary hospital of rural area

    Directory of Open Access Journals (Sweden)

    Yong-Feng Jing

    2018-01-01

    Full Text Available AIM: To describe the application of smart phone and supporting set for acquiring fundus images with slitlamp examination and non-contact lens in primary hospital of the rural area. METHODS: The supporting set for smart phone was purchased from taobao and securely connected to the ocular lens of slitlamp microscopy. The fundus photos were imaged with assistance of non-contact slitlamp lens from Volk. RESULTS: High quality images of various retinal diseases could be successfully taken with smart phone and supporting set by slitlamp examination. The fundus images were send to patients with Wechat as medical records or used for telconsultant. CONCLUSION: High resolution smart phones are wildly used nowadays and supporting sets are very accessible; thus high quality of images could be obtained with minimal cost in rural hospitals. The digital fundus images will be beneficial for medical record and rapid diagnosis with telconsultant.

  9. Fundus autofluorescence in serpiginouslike choroiditis.

    Science.gov (United States)

    Gupta, Amod; Bansal, Reema; Gupta, Vishali; Sharma, Aman

    2012-04-01

    To report the fundus autofluorescence characteristics in serpiginouslike choroiditis. Twenty-nine patients with presumed tubercular serpiginouslike choroiditis between November 2008 and January 2010 underwent fundus autofluorescence imaging during the acute stage and at regular intervals till the lesions healed. All patients received antitubercular therapy with oral corticosteroids. The autofluorescence images were compared with color fundus photography and fundus fluorescein angiography. The main outcome measure was fundus autofluorescence characteristics of lesions during the course of the disease. The pattern of fundus autofluorescence changed as the lesions evolved from the acute to the healed stage. In acute stage, the lesions showed an ill-defined halo of increased autofluorescence (hyperautofluorescence), giving it a diffuse, amorphous appearance (Stage I, acute). As the lesions began to heal, a thin rim of decreased autofluorescence (hypoautofluorescence) surrounded the lesion, defining its edges. The lesions showed predominantly hyperautofluorescence with stippled pattern (Stage II, subacute). With further healing, the hypoautofluorescence progressed and the lesion appeared predominantly hypoautofluorescent with stippled pattern (Stage III, nearly resolved). On complete healing, the lesions became uniformly hypoautofluorescent (Stage IV, completely resolved). Fundus autofluorescence highlighted the areas of disease activity and was a quick imaging tool for monitoring the course of lesions in serpiginouslike choroiditis.

  10. 360/degree/ digital phase detector with 100-kHz bandwidth

    International Nuclear Information System (INIS)

    Reid, D.W.; Riggin, D.; Fazio, M.V.; Biddle, R.S.; Patton, R.D.; Jackson, H.A.

    1981-01-01

    The general availability of digital circuit components with propagation delay times of a few nanoseconds makes a digital phase detector with good bandwidth feasible. Such a circuit has a distinct advantage over its analog counterpart because of its linearity over a wide range of phase shift. A description is given of a phase detector that is being built at Los Alamos National Laboratory for the Fusion Materials Irradiation Test (FMIT) project. The specifications are 100-kHz bandwidth, linearity of /plus or minus/1/degree/ over /plus or minus/180/degree/ of phase shift, and 0.66/degree/ resolution. To date, the circuit has achieved the bandwidth and resolution. The linearity is approximately /plus or minus/3/degree/ over /plus or minus/180/degree/ phase shift. 3 refs

  11. A Web-based telemedicine system for diabetic retinopathy screening using digital fundus photography.

    Science.gov (United States)

    Wei, Jack C; Valentino, Daniel J; Bell, Douglas S; Baker, Richard S

    2006-02-01

    The purpose was to design and implement a Web-based telemedicine system for diabetic retinopathy screening using digital fundus cameras and to make the software publicly available through Open Source release. The process of retinal imaging and case reviewing was modeled to optimize workflow and implement use of computer system. The Web-based system was built on Java Servlet and Java Server Pages (JSP) technologies. Apache Tomcat was chosen as the JSP engine, while MySQL was used as the main database and Laboratory of Neuro Imaging (LONI) Image Storage Architecture, from the LONI-UCLA, as the platform for image storage. For security, all data transmissions were carried over encrypted Internet connections such as Secure Socket Layer (SSL) and HyperText Transfer Protocol over SSL (HTTPS). User logins were required and access to patient data was logged for auditing. The system was deployed at Hubert H. Humphrey Comprehensive Health Center and Martin Luther King/Drew Medical Center of Los Angeles County Department of Health Services. Within 4 months, 1500 images of more than 650 patients were taken at Humphrey's Eye Clinic and successfully transferred to King/Drew's Department of Ophthalmology. This study demonstrates an effective architecture for remote diabetic retinopathy screening.

  12. [Fluorescein angiography and optical coherence tomography findings in central fundus of myopic patients].

    Science.gov (United States)

    Avetisov, S E; Budzinskaya, M V; Zhabina, O A; Andreeva, I V; Plyukhova, A A; Kobzova, M V; Musaeva, G M

    2015-01-01

    Myopia prevalence grows alike in many countries, including Russia, regardless of geographical and population conditions. to assess fundus changes in myopic patients at different ocular axial lengths by means of modern diagnostic tools. The study enrolled 97 patients (194 eyes) aged 45 ± 20.17 years with myopia of different degrees. Besides a standard ophthalmic examination, all patients underwent fundus fluorescein angiography and optical coherence tomography. The occurrence of retinal pigment epithelium (RPE) atrophy (diffuse or focal) has been shown to increase with increasing ocular axial length. Only 27 eyes (28.1%) appeared intact. As myopia progression implies axial growth of the eye, it is associated with a more severe decrease in choroid, RPE, and photoreceptor layer thicknesses: the longer the anterior-posterior axis, the thinner the above mentioned fundus structures. Age-related changes in the fundus are also likely to be more pronounced in longer axes. Myopic traction maculopathy, which in our case appeared the main cause of increased retinal thickness, was diagnosed in 105 eyes, "outer" macular retinoschisis--in 40 eyes. Thus, modern diagnostic tools, such as fluorescein angiography and optical coherence tomography, enable objective assessment of the central fundus.

  13. Ocular Fundus Photography as an Educational Tool.

    Science.gov (United States)

    Mackay, Devin D; Garza, Philip S

    2015-10-01

    The proficiency of nonophthalmologists with direct ophthalmoscopy is poor, which has prompted a search for alternative technologies to examine the ocular fundus. Although ocular fundus photography has existed for decades, its use has been traditionally restricted to ophthalmology clinical care settings and textbooks. Recent research has shown a role for nonmydriatic fundus photography in nonophthalmic settings, encouraging more widespread adoption of fundus photography technology. Recent studies have also affirmed the role of fundus photography as an adjunct or alternative to direct ophthalmoscopy in undergraduate medical education. In this review, the authors examine the use of ocular fundus photography as an educational tool and suggest future applications for this important technology. Novel applications of fundus photography as an educational tool have the potential to resurrect the dying art of funduscopy. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Fundus imaging with a nasal endoscope

    Directory of Open Access Journals (Sweden)

    P Mahesh Shanmugam

    2015-01-01

    Full Text Available Wide field fundus imaging is needed to diagnose, treat, and follow-up patients with retinal pathology. This is more applicable for pediatric patients as repeated evaluation is a challenge. The presently available imaging machines though provide high definition images, but carry the obvious disadvantages of either being costly or bulky or sometimes both, which limits its usage only to large centers. We hereby report a technique of fundus imaging using a nasal endoscope coupled with viscoelastic. A regular nasal endoscope with viscoelastic coupling was placed on the cornea to image the fundus of infants under general anesthesia. Wide angle fundus images of various fundus pathologies in infants could be obtained easily with readily available instruments and without the much financial investment for the institutes.

  15. Fundus autofluorescence imaging of the white dot syndromes.

    Science.gov (United States)

    Yeh, Steven; Forooghian, Farzin; Wong, Wai T; Faia, Lisa J; Cukras, Catherine; Lew, Julie C; Wroblewski, Keith; Weichel, Eric D; Meyerle, Catherine B; Sen, Hatice Nida; Chew, Emily Y; Nussenblatt, Robert B

    2010-01-01

    To characterize the fundus autofluorescence (FAF) findings in patients with white dot syndromes (WDSs). Patients with WDSs underwent ophthalmic examination, fundus photography, fluorescein angiography, and FAF imaging. Patients were categorized as having no, minimal, or predominant foveal hypoautofluorescence. The severity of visual impairment was then correlated with the degree of foveal hypoautofluorescence. Fifty-five eyes of 28 patients with WDSs were evaluated. Visual acuities ranged from 20/12.5 to hand motions. Diagnoses included serpiginous choroidopathy (5 patients), birdshot retinochoroidopathy (10), multifocal choroiditis (8), relentless placoid chorioretinitis (1), presumed tuberculosis-associated serpiginouslike choroidopathy (1), acute posterior multifocal placoid pigment epitheliopathy (1), and acute zonal occult outer retinopathy (2). In active serpiginous choroidopathy, notable hyperautofluorescence in active disease distinguished it from the variegated FAF features of tuberculosis-associated serpiginouslike choroidopathy. The percentage of patients with visual acuity impairment of less than 20/40 differed among eyes with no, minimal, and predominant foveal hypoautofluorescence (P < .001). Patients with predominant foveal hypoautofluorescence demonstrated worse visual acuity than those with minimal or no foveal hypoautofluorescence (both P < .001). Fundus autofluorescence imaging is useful in the evaluation of the WDS. Visual acuity impairment is correlated with foveal hypoautofluorescence. Further studies are needed to evaluate the precise role of FAF imaging in the WDSs.

  16. Infrared-laser-based fundus angiography

    Science.gov (United States)

    Klingbeil, Ulrich; Canter, Joseph M.; Lesiecki, Michael L.; Reichel, Elias

    1994-06-01

    Infrared fundus angiography, using the fluorescent dye indocyanine green (ICG), has shown great potential in delineating choroidal neovascularization (CNV) otherwise not detectable. A digital retinal imaging system containing a diode laser for illumination has been developed and optimized to perform high sensitivity ICG angiography. The system requires less power and generates less pseudo-fluorescence background than nonlaser devices. During clinical evaluation at three retinal centers more than 200 patients, the majority of which had age-related macular degeneration, were analyzed. Laser based ICG angiography was successful in outlining many of the ill-defined or obscure CNV as defined by fluorescein angiography. The procedure was not as successful with classic CNV. ICG angiograms were used to prepare and guide laser treatment.

  17. Genetics Home Reference: fundus albipunctatus

    Science.gov (United States)

    ... Lorenz B, Sander B, Larsen M, Eckstein C, Rosenberg T. Lack of autofluorescence in fundus albipunctatus associated ... Preising M, Lorenz B, Sander B, Larsen M, Rosenberg T. Fundus albipunctatus associated with compound heterozygous mutations ...

  18. Clinical Investigation of Radiation Retinopathy Fundus and Fluorescein Angiographic Features

    Institute of Scientific and Technical Information of China (English)

    LiMei; QiuGT

    1999-01-01

    Purpose:To investigate the fundus and fluorescein angiographic features in the patients with radiation retinopathy.Clinical Materials:Color fundus photography and/or fluorescein angiography from 13 patients with nasopharyngeal carcinomas received external beam radiation were retrospectively analyzed.Reslts:In this study,26 damaged eyes of 13 patients eveloped some degree of radiation retinopathy.The earliest and most common finding was macular microvascular changes (microaneurysms and/or telangiectasia),which was observed in 100%(26/26)of the eyes.Intraretinal hemorrhages,macular capillary nonperfusion,and macular edema were noted in 84%,50%,and 42% of the eyes,respectively.Conclusions:Radiation retinopathy is common after external beam radiation of nasopharyngeal carcinomas.The prominent changes include maular microvascular changes,intraretinal hemorrhages and macular capillary nonperfusion.

  19. An evaluation of fundus photography and fundus autofluorescence in the diagnosis of cuticular drusen

    DEFF Research Database (Denmark)

    Høeg, Tracy B; Moldow, Birgitte; Klein, Ronald

    2016-01-01

    PURPOSE: To examine non-mydriatic fundus photography (FP) and fundus autofluorescence (FAF) as alternative non-invasive imaging modalities to fluorescein angiography (FA) in the detection of cuticular drusen (CD). METHODS: Among 2953 adults from the Danish Rural Eye Study (DRES) with gradable FP...

  20. Automated detection of fundus photographic red lesions in diabetic retinopathy.

    Science.gov (United States)

    Larsen, Michael; Godt, Jannik; Larsen, Nicolai; Lund-Andersen, Henrik; Sjølie, Anne Katrin; Agardh, Elisabet; Kalm, Helle; Grunkin, Michael; Owens, David R

    2003-02-01

    To compare a fundus image-analysis algorithm for automated detection of hemorrhages and microaneurysms with visual detection of retinopathy in patients with diabetes. Four hundred fundus photographs (35-mm color transparencies) were obtained in 200 eyes of 100 patients with diabetes who were randomly selected from the Welsh Community Diabetic Retinopathy Study. A gold standard reference was defined by classifying each patient as having or not having diabetic retinopathy based on overall visual grading of the digitized transparencies. A single-lesion visual grading was made independently, comprising meticulous outlining of all single lesions in all photographs and used to develop the automated red lesion detection system. A comparison of visual and automated single-lesion detection in replicating the overall visual grading was then performed. Automated red lesion detection demonstrated a specificity of 71.4% and a resulting sensitivity of 96.7% in detecting diabetic retinopathy when applied at a tentative threshold setting for use in diabetic retinopathy screening. The accuracy of 79% could be raised to 85% by adjustment of a single user-supplied parameter determining the balance between the screening priorities, for which a considerable range of options was demonstrated by the receiver-operating characteristic (area under the curve 90.3%). The agreement of automated lesion detection with overall visual grading (0.659) was comparable to the mean agreement of six ophthalmologists (0.648). Detection of diabetic retinopathy by automated detection of single fundus lesions can be achieved with a performance comparable to that of experienced ophthalmologists. The results warrant further investigation of automated fundus image analysis as a tool for diabetic retinopathy screening.

  1. The grey fovea sign of macular oedema or subfoveal fluid on non-stereoscopic fundus photographs

    DEFF Research Database (Denmark)

    Hasler, Pascal W; Soliman, Wael; Sander, Birgit

    2017-01-01

    PURPOSE: To describe the grey fovea sign of fovea-involving macular oedema or subretinal fluid accumulation in red-free fundus photography. METHODS: A test set of 91 digital fundus photographs of good quality from 100 consecutive eyes in 72 patients with diabetic retinopathy or central serous...... chorioretinopathy was composed by one of the investigators and evaluated by four masked observers. The photographs were graded as to whether a normal dark fovea was present or absent. The reference method was foveal thickness measurement using optical coherence tomography (OCT). RESULTS: Eyes graded as having...... a grey fovea on fundus photographs (n = 67) had a median foveal thickness of 279 μm (interquartile range 130 μm), whereas eyes graded as having a normal dark fovea (n = 24) had a median foveal thickness of 238 μm (interquartile range 44.5 μm, p = 0.025). CONCLUSION: The absence of a dark fovea on red...

  2. A Method of Drusen Measurement Based on the Geometry of Fundus Reflectance

    Directory of Open Access Journals (Sweden)

    Barbazetto Irene

    2003-04-01

    Full Text Available Abstract Background The hallmarks of age-related macular degeneration, the leading cause of blindness in the developed world, are the subretinal deposits known as drusen. Drusen identification and measurement play a key role in clinical studies of this disease. Current manual methods of drusen measurement are laborious and subjective. Our purpose was to expedite clinical research with an accurate, reliable digital method. Methods An interactive semi-automated procedure was developed to level the macular background reflectance for the purpose of morphometric analysis of drusen. 12 color fundus photographs of patients with age-related macular degeneration and drusen were analyzed. After digitizing the photographs, the underlying background pattern in the green channel was leveled by an algorithm based on the elliptically concentric geometry of the reflectance in the normal macula: the gray scale values of all structures within defined elliptical boundaries were raised sequentially until a uniform background was obtained. Segmentation of drusen and area measurements in the central and middle subfields (1000 μm and 3000 μm diameters were performed by uniform thresholds. Two observers using this interactive semi-automated software measured each image digitally. The mean digital measurements were compared to independent stereo fundus gradings by two expert graders (stereo Grader 1 estimated the drusen percentage in each of the 24 regions as falling into one of four standard broad ranges; stereo Grader 2 estimated drusen percentages in 1% to 5% intervals. Results The mean digital area measurements had a median standard deviation of 1.9%. The mean digital area measurements agreed with stereo Grader 1 in 22/24 cases. The 95% limits of agreement between the mean digital area measurements and the more precise stereo gradings of Grader 2 were -6.4 % to +6.8 % in the central subfield and -6.0 % to +4.5 % in the middle subfield. The mean absolute

  3. Fundus Autofluorescence Features of Optic Disc Pit Related ...

    African Journals Online (AJOL)

    chorioretinopathy, retina telangiectasia and diffuse and macula retina dystrophies.[1,3‑8] These features give useful clinical and prognostic information, making FAF a desired day‑to‑day clinical tool. Fundus autoflorescence signals can be detected using 3 different systems, the Delori's fundus. Fundus Autofluorescence ...

  4. CORRELATION OF FUNDUS CHANGES IN RELATION TO REFRACTIVE ERROR IN PATIENTS WITH MYOPIA- A CLINICAL PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Balasubramanian M. Manickavelu

    2018-01-01

    Full Text Available BACKGROUND Retina is unique among the complex element of the central nervous system and the special senses. It may be readily viewed during life and it is sufficiently transparent, so that alterations within and adjacent to it may be observed in vivo. The peripheral retina owing to its thinness comparing to that of the central part, poorly-developed retinal cells, absence of large blood vessels, relatively insensitive to light, less resistance to traction, forms a seat for various lesions, which are potentially dangerous for the vision. It is in myopia that we meet the most frequent and the most obvious anomalies in the fundus changes, which bear some relation to the degree of myopia and appeal to be concerned with it either as a cause or effect or perhaps both. The aim of our study is to correlate fundus changes in relation to refractive error in patients with myopia. MATERIALS AND METHODS In our study, 100 cases of myopic (-6D:50 cases patients were selected. Detailed evaluation done. History of refractive error includes duration, age at which spectacles were worn for the first time. Time of last change of spectacles, family history of myopia, history of other symptoms like progressive loss of vision, defective vision related to day or night, sudden loss of vision, flashes and floaters. Anterior segment was examined followed by the recording of initial visual acuity and the best corrected visual acuity was noted. IOP was measured for all the cases using Schiotz tonometry. Axial length was measured in all the cases. Fundus examined with direct ophthalmoscope, indirect ophthalmoscope, 3 mirror and 90D lens. Bscan was done in few cases. The media, disc, vessels, macula and the surrounding retina were examined. The periphery was examined with indentation method. The various fundus features and pathological lesions in different degrees of myopia were noted. RESULTS Females were comparatively more affected. Highest incidence was seen in the younger

  5. 21 CFR 886.1395 - Diagnostic Hruby fundus lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic Hruby fundus lens. 886.1395 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1395 Diagnostic Hruby fundus lens. (a) Identification. A diagnostic Hruby fundus lens is a device that is a 55 diopter lens intended for use in the...

  6. Semi-automated retinal vessel analysis in nonmydriatic fundus photography.

    Science.gov (United States)

    Schuster, Alexander Karl-Georg; Fischer, Joachim Ernst; Vossmerbaeumer, Urs

    2014-02-01

    Funduscopic assessment of the retinal vessels may be used to assess the health status of microcirculation and as a component in the evaluation of cardiovascular risk factors. Typically, the evaluation is restricted to morphological appreciation without strict quantification. Our purpose was to develop and validate a software tool for semi-automated quantitative analysis of retinal vasculature in nonmydriatic fundus photography. matlab software was used to develop a semi-automated image recognition and analysis tool for the determination of the arterial-venous (A/V) ratio in the central vessel equivalent on 45° digital fundus photographs. Validity and reproducibility of the results were ascertained using nonmydriatic photographs of 50 eyes from 25 subjects recorded from a 3DOCT device (Topcon Corp.). Two hundred and thirty-three eyes of 121 healthy subjects were evaluated to define normative values. A software tool was developed using image thresholds for vessel recognition and vessel width calculation in a semi-automated three-step procedure: vessel recognition on the photograph and artery/vein designation, width measurement and calculation of central retinal vessel equivalents. Mean vessel recognition rate was 78%, vessel class designation rate 75% and reproducibility between 0.78 and 0.91. Mean A/V ratio was 0.84. Application on a healthy norm cohort showed high congruence with prior published manual methods. Processing time per image was one minute. Quantitative geometrical assessment of the retinal vasculature may be performed in a semi-automated manner using dedicated software tools. Yielding reproducible numerical data within a short time leap, this may contribute additional value to mere morphological estimates in the clinical evaluation of fundus photographs. © 2013 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  7. Quantitative fundus autofluorescence in recessive Stargardt disease.

    Science.gov (United States)

    Burke, Tomas R; Duncker, Tobias; Woods, Russell L; Greenberg, Jonathan P; Zernant, Jana; Tsang, Stephen H; Smith, R Theodore; Allikmets, Rando; Sparrow, Janet R; Delori, François C

    2014-05-01

    To quantify fundus autofluorescence (qAF) in patients with recessive Stargardt disease (STGD1). A total of 42 STGD1 patients (ages: 7-52 years) with at least one confirmed disease-associated ABCA4 mutation were studied. Fundus AF images (488-nm excitation) were acquired with a confocal scanning laser ophthalmoscope equipped with an internal fluorescent reference to account for variable laser power and detector sensitivity. The gray levels (GLs) of each image were calibrated to the reference, zero GL, magnification, and normative optical media density to yield qAF. Texture factor (TF) was calculated to characterize inhomogeneities in the AF image and patients were assigned to the phenotypes of Fishman I through III. Quantified fundus autofluorescence in 36 of 42 patients and TF in 27 of 42 patients were above normal limits for age. Young patients exhibited the relatively highest qAF, with levels up to 8-fold higher than healthy eyes. Quantified fundus autofluorescence and TF were higher in Fishman II and III than Fishman I, who had higher qAF and TF than healthy eyes. Patients carrying the G1916E mutation had lower qAF and TF than most other patients, even in the presence of a second allele associated with severe disease. Quantified fundus autofluorescence is an indirect approach to measuring RPE lipofuscin in vivo. We report that ABCA4 mutations cause significantly elevated qAF, consistent with previous reports indicating that increased RPE lipofuscin is a hallmark of STGD1. Even when qualitative differences in fundus AF images are not evident, qAF can elucidate phenotypic variation. Quantified fundus autofluorescence will serve to establish genotype-phenotype correlations and as an outcome measure in clinical trials.

  8. Quantitative Fundus Autofluorescence in Recessive Stargardt Disease

    Science.gov (United States)

    Burke, Tomas R.; Duncker, Tobias; Woods, Russell L.; Greenberg, Jonathan P.; Zernant, Jana; Tsang, Stephen H.; Smith, R. Theodore; Allikmets, Rando; Sparrow, Janet R.; Delori, François C.

    2014-01-01

    Purpose. To quantify fundus autofluorescence (qAF) in patients with recessive Stargardt disease (STGD1). Methods. A total of 42 STGD1 patients (ages: 7–52 years) with at least one confirmed disease-associated ABCA4 mutation were studied. Fundus AF images (488-nm excitation) were acquired with a confocal scanning laser ophthalmoscope equipped with an internal fluorescent reference to account for variable laser power and detector sensitivity. The gray levels (GLs) of each image were calibrated to the reference, zero GL, magnification, and normative optical media density to yield qAF. Texture factor (TF) was calculated to characterize inhomogeneities in the AF image and patients were assigned to the phenotypes of Fishman I through III. Results. Quantified fundus autofluorescence in 36 of 42 patients and TF in 27 of 42 patients were above normal limits for age. Young patients exhibited the relatively highest qAF, with levels up to 8-fold higher than healthy eyes. Quantified fundus autofluorescence and TF were higher in Fishman II and III than Fishman I, who had higher qAF and TF than healthy eyes. Patients carrying the G1916E mutation had lower qAF and TF than most other patients, even in the presence of a second allele associated with severe disease. Conclusions. Quantified fundus autofluorescence is an indirect approach to measuring RPE lipofuscin in vivo. We report that ABCA4 mutations cause significantly elevated qAF, consistent with previous reports indicating that increased RPE lipofuscin is a hallmark of STGD1. Even when qualitative differences in fundus AF images are not evident, qAF can elucidate phenotypic variation. Quantified fundus autofluorescence will serve to establish genotype-phenotype correlations and as an outcome measure in clinical trials. PMID:24677105

  9. Comparison of Color Fundus Photography, Infrared Fundus Photography, and Optical Coherence Tomography in Detecting Retinal Hamartoma in Patients with Tuberous Sclerosis Complex.

    Science.gov (United States)

    Bai, Da-Yong; Wang, Xu; Zhao, Jun-Yang; Li, Li; Gao, Jun; Wang, Ning-Li

    2016-05-20

    A sensitive method is required to detect retinal hamartomas in patients with tuberous sclerosis complex (TSC). The aim of the present study was to compare the color fundus photography, infrared imaging (IFG), and optical coherence tomography (OCT) in the detection rate of retinal hamartoma in patients with TSC. This study included 11 patients (22 eyes) with TSC, who underwent color fundus photography, IFG, and spectral-domain OCT to detect retinal hamartomas. TSC1 and TSC2RESULTS: The mean age of the 11 patients was 8.0 ± 2.1 years. The mean spherical equivalent was -0.55 ± 1.42 D by autorefraction with cycloplegia. In 11 patients (22 eyes), OCT, infrared fundus photography, and color fundus photography revealed 26, 18, and 9 hamartomas, respectively. The predominant hamartoma was type I (55.6%). All the hamartomas that detected by color fundus photography or IFG can be detected by OCT. Among the methods of color fundus photography, IFG, and OCT, the OCT has higher detection rate for retinal hamartoma in TSC patients; therefore, OCT might be promising for the clinical diagnosis of TSC.

  10. Evaluating two methods of digital photography in retinopathy screening

    Directory of Open Access Journals (Sweden)

    Li Chen

    2018-02-01

    Full Text Available AIM:To evaluate the advantages of non-mydriatic fundus photography(NMFCSand mydriatic fundus photography(MFCSas eye-bottom screening and diagnosis methods in compared with gold standard fluorescein fundus angiography(FFA. METHODS: A total of 276 patients which involved in Chronic Diabetes Management Achieves within 4 streets of Pudong District Shanghai, were enrolled for diabetic retinopathy(DRexamination including NMFCS, MFCS and FFA. These DR examinations were proceeded after vision, slit-lamp and dioptroscopy tests, and reported by professionals. For those with suspicious fundus diseases, we would make appointments with specialist for further treatment. RESULTS: A total of 1104 colorful fundus images, and 1056 images(95.65%could be used to analyze. There were 408 appreciable images, 116 basically appreciable images and 28 unusable images in 552 NMFCS images. In addition, there were 432 appreciable images, 100 basically appreciable images and 20 unusable images in 552 MFCS images. There was no significant differences between NMFCS and MFCS(P>0.05. Compared with FFA with DRⅠ as the critical value, the specificity of digital photography for NMFCS was 95.71%, the sensitivity was 93.56%; however, MFCS are 95.43% and 98.02%. There was no statistically significant difference between the two screening methods(P>0.05. Compared with FFA with DRⅡ as the critical value, the specificity of digital photography for NMFCS was 95.35% and the sensitivity was 93.44%; however, for MFCS were 95.81% and 98.36%. There was no statistically significant difference between the two screening methods(P>0.05. CONCLUSION: Both NMFCS and MFCS could be used for the diagnosis and screening for eye diseases. NMFCS is easier and faster for digital photography, which is suitable for mass screening. MFCS is more likely to provide detailed information about the follow-up of the disease.

  11. Interoperative fundus image and report sharing in compliance with integrating the healthcare enterprise conformance and web access todigital imaging and communication in medicinepersistent object protocol

    Directory of Open Access Journals (Sweden)

    Hui-Qun Wu

    2013-12-01

    Full Text Available AIM:To address issues in interoperability between different fundus image systems, we proposed a web eye-picture archiving and communication system (PACS framework in conformance with digital imaging and communication in medicine (DICOM and health level 7 (HL7 protocol to realize fundus images and reports sharing and communication through internet.METHODS: Firstly, a telemedicine-based eye care work flow was established based on integrating the healthcare enterprise (IHE Eye Care technical framework. Then, a browser/server architecture eye-PACS system was established in conformance with the web access to DICOM persistent object (WADO protocol, which contains three tiers.RESULTS:In any client system installed with web browser, clinicians could log in the eye-PACS to observe fundus images and reports. Multipurpose internet mail extensions (MIME type of a structured report is saved as pdf/html with reference link to relevant fundus image using the WADO syntax could provide enough information for clinicians. Some functions provided by open-source Oviyam could be used to query, zoom, move, measure, view DICOM fundus images.CONCLUSION:Such web eye-PACS in compliance to WADO protocol could be used to store and communicate fundus images and reports, therefore is of great significance for teleophthalmology.

  12. Grading of 7-standard field fundus photography for diagosis of diabetic retinopathy%七方位彩色眼底照像法对糖尿病视网膜病变的诊断价值

    Institute of Scientific and Technical Information of China (English)

    赵琳; 刘瑜玲; 鹿欣荣; 钱芳; 张敏

    2009-01-01

    Objeetive To evaluate the ability ofmydriatic single-field 50°digital fundus photography and mydriatic 7-standard field fundus photography to detect diabetic retinopathy (DR)in patients with diabetic mellitus (DM)compared with fluorescein fundus angiography (FFA).Methods A Total of 164 diabetic patients attending a hospital-based screening clinic were recruited.Mydriatie single-field 50°digital fundus photography,mydriatic 7-standard field ETDRS fundus photography and FFA were performed using a Zeiss ff450 plus IR fundus camera.Grading of diabetic retinopathy was carried out by two ophthalmologists with diabetic retinopathy international clinical classification.The results were evaluated and compared respectively.ResuitsMydriatic single-field 50°digital fundus photography and FFA demonstrated moderate agreement (k=0.488).Mydriatic 7-standard field fundns photography and FFA demonstrated near perfect agreement (k=0.873).Conclusion Mydriatic 7-standard field fundus photography is an effective and clinically viable technique to screen for diabetic retinopathy among a diabetic population,Mydriatic single-field 50°digital fundus photography moderate.%目的 筛选经济、简便、有效地糖尿病视网膜病变检查法.方法 分别采用散瞳50度眼底后极部彩色照像法、美国早期糖尿病性视网膜病变治疗研究小组确立的散瞳30度眼底七方位彩色照像法和FFA法对164例(308只眼)糖尿病患者进行检查,由有经验的眼底医生按照糖尿病视网膜病变国际临床分类法对图片进行分析给出分期,对三种方法所得结果进行比较.结果 散瞳50度眼底后极部彩色照像法和FFA法在DR诊断分期中一致性一般(k=0.488),七方位彩色眼底照像法和FFA法在DR诊断分期中有比较好的一致性(k=0.873).结论 七方位彩色眼底照像法可作为糖尿病视网膜病变筛查和指导治疗的一种比较可靠的方法,而散瞳50度眼底后极部彩色照像法的可靠性一般.

  13. FUNDUS AUTOFLUORESCENCE LIFETIMES AND CENTRAL SEROUS CHORIORETINOPATHY.

    Science.gov (United States)

    Dysli, Chantal; Berger, Lieselotte; Wolf, Sebastian; Zinkernagel, Martin S

    2017-11-01

    To quantify retinal fluorescence lifetimes in patients with central serous chorioretinopathy (CSC) and to identify disease specific lifetime characteristics over the course of disease. Forty-seven participants were included in this study. Patients with central serous chorioretinopathy were imaged with fundus photography, fundus autofluorescence, optical coherence tomography, and fluorescence lifetime imaging ophthalmoscopy (FLIO) and compared with age-matched controls. Retinal autofluorescence was excited using a 473-nm blue laser light and emitted fluorescence light was detected in 2 distinct wavelengths channels (498-560 nm and 560-720 nm). Clinical features, mean retinal autofluorescence lifetimes, autofluorescence intensity, and corresponding optical coherence tomography (OCT) images were further analyzed. Thirty-five central serous chorioretinopathy patients with a mean visual acuity of 78 ETDRS letters (range, 50-90; mean Snellen equivalent: 20/32) and 12 age-matched controls were included. In the acute stage of central serous chorioretinopathy, retinal fluorescence lifetimes were shortened by 15% and 17% in the respective wavelength channels. Multiple linear regression analysis showed that fluorescence lifetimes were significantly influenced by the disease duration (P autofluorescence lifetimes, particularly in eyes with retinal pigment epithelial atrophy, were associated with poor visual acuity. This study establishes that autofluorescence lifetime changes occurring in central serous chorioretinopathy exhibit explicit patterns which can be used to estimate perturbations of the outer retinal layers with a high degree of statistical significance.

  14. The Spectrum of Fundus Autofluorescence Findings in Birdshot Chorioretinopathy

    Directory of Open Access Journals (Sweden)

    GianPaolo Giuliari

    2009-01-01

    Full Text Available Objective. To describe the diverse patterns observed with the use of autofluorescence fundus photography (FAF in patients with Birdshot chorioretinopathy (BSCR. Methods. A chart review of patients with BSCR seen at the Massachusetts Eye Research and Surgery Institution, who had autofluorescence fundus photography. The data obtained included age, gender, presence of the HLA-A29 haplotype, and current treatment. Results. Eighteen eyes with HLA-A29 associated BSCR were included. Four eyes presented with active inflammation. Correspondence of the lesions noted in the colour fundus photograph was observed in 3 eyes which were more easily identified with the FAF. Fifteen eyes had fundus lesions more numerous and evident in the FAF than in the colour fundus photograph. Conclusion. Because FAF testing provides valuable insight into the metabolic state of the PR/RPE-complex, it may serve as a useful noninvasive assessment tool in patients with posterior uveitis in which the outer retina-RPE-choriocapillaries-complex is involved.

  15. A Phenomenological Study of the Lived Experiences of Digital Immigrants in a Fully Online Master's Degree Program

    Science.gov (United States)

    Kieschnick, Stuart

    2012-01-01

    This qualitative study was designed to investigate the challenges encountered and support systems needed by digital immigrants enrolled in an online master's degree program. Participants were digital immigrants who were born before 1980 and enrolled or recently graduated from an online master's degree program. Survey data and demographic data were…

  16. Automated classification and quantitative analysis of arterial and venous vessels in fundus images

    Science.gov (United States)

    Alam, Minhaj; Son, Taeyoon; Toslak, Devrim; Lim, Jennifer I.; Yao, Xincheng

    2018-02-01

    It is known that retinopathies may affect arteries and veins differently. Therefore, reliable differentiation of arteries and veins is essential for computer-aided analysis of fundus images. The purpose of this study is to validate one automated method for robust classification of arteries and veins (A-V) in digital fundus images. We combine optical density ratio (ODR) analysis and blood vessel tracking algorithm to classify arteries and veins. A matched filtering method is used to enhance retinal blood vessels. Bottom hat filtering and global thresholding are used to segment the vessel and skeleton individual blood vessels. The vessel tracking algorithm is used to locate the optic disk and to identify source nodes of blood vessels in optic disk area. Each node can be identified as vein or artery using ODR information. Using the source nodes as starting point, the whole vessel trace is then tracked and classified as vein or artery using vessel curvature and angle information. 50 color fundus images from diabetic retinopathy patients were used to test the algorithm. Sensitivity, specificity, and accuracy metrics were measured to assess the validity of the proposed classification method compared to ground truths created by two independent observers. The algorithm demonstrated 97.52% accuracy in identifying blood vessels as vein or artery. A quantitative analysis upon A-V classification showed that average A-V ratio of width for NPDR subjects with hypertension decreased significantly (43.13%).

  17. Quality Enhancement and Nerve Fibre Layer Artefacts Removal in Retina Fundus Images by Off Axis Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Meriaudeau, Fabrice [ORNL; Karnowski, Thomas Paul [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK); Tobin Jr, Kenneth William [ORNL; Chaum, Edward [University of Tennessee, Knoxville (UTK)

    2011-01-01

    Retinal fundus images acquired with non-mydriatic digital fundus cameras are a versatile tool for the diagnosis of various retinal diseases. Because of the ease of use of newer camera models and their relative low cost, these cameras are employed worldwide by retina specialists to diagnose diabetic retinopathy and other degenerative diseases. Even with relative ease of use, the images produced by these systems sometimes suffer from reflectance artefacts mainly due to the nerve fibre layer (NFL) or other camera lens related reflections. We propose a technique that employs multiple fundus images acquired from the same patient to obtain a single higher quality image without these reflectance artefacts. The removal of bright artefacts, and particularly of NFL reflectance, can have great benefits for the reduction of false positives in the detection of retinal lesions such as exudate, drusens and cotton wool spots by automatic systems or manual inspection. If enough redundant information is provided by the multiple images, this technique also compensates for a suboptimal illumination. The fundus images are acquired in straightforward but unorthodox manner, i.e. the stare point of the patient is changed between each shot but the camera is kept fixed. Between each shot, the apparent shape and position of all the retinal structures that do not exhibit isotropic reflectance (e.g. bright artefacts) change. This physical effect is exploited by our algorithm in order to extract the pixels belonging to the inner layers of the retina, hence obtaining a single artefacts-free image.

  18. Non-mydriatic, wide field, fundus video camera

    Science.gov (United States)

    Hoeher, Bernhard; Voigtmann, Peter; Michelson, Georg; Schmauss, Bernhard

    2014-02-01

    We describe a method we call "stripe field imaging" that is capable of capturing wide field color fundus videos and images of the human eye at pupil sizes of 2mm. This means that it can be used with a non-dilated pupil even with bright ambient light. We realized a mobile demonstrator to prove the method and we could acquire color fundus videos of subjects successfully. We designed the demonstrator as a low-cost device consisting of mass market components to show that there is no major additional technical outlay to realize the improvements we propose. The technical core idea of our method is breaking the rotational symmetry in the optical design that is given in many conventional fundus cameras. By this measure we could extend the possible field of view (FOV) at a pupil size of 2mm from a circular field with 20° in diameter to a square field with 68° by 18° in size. We acquired a fundus video while the subject was slightly touching and releasing the lid. The resulting video showed changes at vessels in the region of the papilla and a change of the paleness of the papilla.

  19. Fundus Autofluorescence and Photoreceptor Cell Rosettes in Mouse Models

    Science.gov (United States)

    Flynn, Erin; Ueda, Keiko; Auran, Emily; Sullivan, Jack M.; Sparrow, Janet R.

    2014-01-01

    Purpose. This study was conducted to study correlations among fundus autofluorescence (AF), RPE lipofuscin accumulation, and photoreceptor cell degeneration and to investigate the structural basis of fundus AF spots. Methods. Fundus AF images (55° lens; 488-nm excitation) and spectral-domain optical coherence tomography (SD-OCT) scans were acquired in pigmented Rdh8−/−/Abca4−/− mice (ages 1–9 months) with a confocal scanning laser ophthalmoscope (cSLO). For quantitative fundus AF (qAF), gray levels (GLs) were calibrated to an internal fluorescence reference. Retinal bisretinoids were measured by quantitative HPLC. Histometric analysis of outer nuclear layer (ONL) thicknesses was performed, and cryostat sections of retina were examined by fluorescence microscopy. Results. Quantified A2E and qAF intensities increased until age 4 months in the Rdh8−/−/Abca4−/− mice. The A2E levels declined after 4 months of age, but qAF intensity values continued to rise. The decline in A2E levels in the Rdh8−/−/Abca4−/− mice paralleled reduced photoreceptor cell viability as reflected in ONL thinning. Hyperautofluorescent puncta in fundus AF images corresponded to photoreceptor cell rosettes in SD-OCT images and histological sections stained with hematoxylin and eosin. The inner segment/outer segment–containing core of the rosette emitted an autofluorescence detected by fluorescence microscopy. Conclusions. When neural retina is disordered, AF from photoreceptor cells can contribute to noninvasive fundus AF images. Hyperautofluorescent puncta in fundus AF images are attributable, in at least some cases, to photoreceptor cell rosettes. PMID:25015357

  20. Fundus Otoflöresans

    OpenAIRE

    ŞERMET, Figen

    2017-01-01

    Fundus otoflöresans görüntüleme, retina hastalıklarında patofizyolojik mekanizmaların anlaşılması, tanı, fenotipgenotipkorelasyonu, hastalık progresyonunu etkileyen faktörlerin belirlenmesi ve tedavi monitörizasyonunda yararlı birgörüntüleme yöntemidir. Fundus otoflöresans görüntüleme birçok hastalığın tanı ve takibinde kullanılabilir. Bu derlemedefundus otoflöresans görüntülemenin retina hastalıkları ve ayırıcı tanısında önemli rol oynadığı hastalıklar klinik olgufotoğraflarıyla da desteklen...

  1. A study of fundus status in myopia

    Directory of Open Access Journals (Sweden)

    Christina Samuel, Sundararajan D

    2014-07-01

    Full Text Available Background: The most important sensory organ for a human is the eye. Any damage to the retina can cause diminution or loss of vision. One of the most important refractive errors of the eye is Myopia apart from hypermetropia and astigmatism. It is one of the commonest conditions seen in everyday practice. Myopic degeneration is one of the common causes of decreased visual acuity. Aim: The aim of this clinical study is to observe the fundus changes associated with Myopia. Methods: A prospective study of 100 cases of myopia were included in this study. Detailed anterior segment and good posterior segment examination after achieving mydriasis was done with a direct ophthalmoscope and indirect ophthalmoscope with 20D lens. Result: In our study, we found that males were more commonly affected than females with myopia (54%. 50% of the cases affected belonged to the student community. 53.68% had positive changes in the retina suggestive of degenerative changes in the fundus. Conclusion: Degenerative changes of fundus are most commonly seen in myopic patients of which Tessellated fundus was about 90.20%. Vitreous degenerative changes for 70.59%. Crescent formation was 87.25%. Dull foveal reflex in 82.35% and lattice degeneration accounted for 40%.

  2. Fundus autofluorescence and colour fundus imaging compared during telemedicine screening in patients with diabetes.

    Science.gov (United States)

    Kolomeyer, Anton M; Baumrind, Benjamin R; Szirth, Bernard C; Shahid, Khadija; Khouri, Albert S

    2013-06-01

    We investigated the use of fundus autofluorescence (FAF) imaging in screening the eyes of patients with diabetes. Images were obtained from 50 patients with type 2 diabetes undergoing telemedicine screening with colour fundus imaging. The colour and FAF images were obtained with a 15.1 megapixel non-mydriatic retinal camera. Colour and FAF images were compared for pathology seen in nonproliferative and proliferative diabetic retinopathy (NPDR and PDR, respectively). A qualitative assessment was made of the ease of detecting early retinopathy changes and the extent of existing retinopathy. The mean age of the patients was 47 years, most were male (82%) and most were African American (68%). Their mean visual acuity was 20/45 and their mean intraocular pressure was 14.3 mm Hg. Thirty-eight eyes (76%) did not show any diabetic retinopathy changes on colour or FAF imaging. Seven patients (14%) met the criteria for NPDR and five (10%) for severe NPDR or PDR. The most common findings were microaneurysms, hard exudates and intra-retinal haemorrhages (IRH) (n = 6 for each). IRH, microaneurysms and chorioretinal scars were more easily visible on FAF images. Hard exudates, pre-retinal haemorrhage and fibrosis, macular oedema and Hollenhorst plaque were easier to identify on colour photographs. The value of FAF imaging as a complementary technique to colour fundus imaging in detecting diabetic retinopathy during ocular screening warrants further investigation.

  3. The Design of an Undergraduate Degree Program in Computer & Digital Forensics

    Directory of Open Access Journals (Sweden)

    Gary C. Kessler

    2006-09-01

    Full Text Available Champlain College formally started an undergraduate degree program in Computer & Digital Forensics in 2003. The underlying goals were that the program be multidisciplinary, bringing together the law, computer technology, and the basics of digital investigations; would be available as on online and on-campus offering; and would have a process-oriented focus. Success of this program has largely been due to working closely with practitioners, maintaining activity in events related to both industry and academia, and flexibility to respond to ever-changing needs. This paper provides an overview of how this program was conceived, developed, and implemented; its evolution over time; and current and planned initiatives.

  4. Do it yourself smartphone fundus camera – DIYretCAM

    Directory of Open Access Journals (Sweden)

    Biju Raju

    2016-01-01

    Full Text Available This article describes the method to make a do it yourself smartphone-based fundus camera which can image the central retina as well as the peripheral retina up to the pars plana. It is a cost-effective alternative to the fundus camera.

  5. Realization of the ergonomics design and automatic control of the fundus cameras

    Science.gov (United States)

    Zeng, Chi-liang; Xiao, Ze-xin; Deng, Shi-chao; Yu, Xin-ye

    2012-12-01

    The principles of ergonomics design in fundus cameras should be extending the agreeableness by automatic control. Firstly, a 3D positional numerical control system is designed for positioning the eye pupils of the patients who are doing fundus examinations. This system consists of a electronically controlled chin bracket for moving up and down, a lateral movement of binocular with the detector and the automatic refocusing of the edges of the eye pupils. Secondly, an auto-focusing device for the object plane of patient's fundus is designed, which collects the patient's fundus images automatically whether their eyes is ametropic or not. Finally, a moving visual target is developed for expanding the fields of the fundus images.

  6. Digital tool for detecting diabetic retinopathy in retinography image using gabor transform

    Science.gov (United States)

    Morales, Y.; Nuñez, R.; Suarez, J.; Torres, C.

    2017-01-01

    Diabetic retinopathy is a chronic disease and is the leading cause of blindness in the population. The fundamental problem is that diabetic retinopathy is usually asymptomatic in its early stage and, in advanced stages, it becomes incurable, hence the importance of early detection. To detect diabetic retinopathy, the ophthalmologist examines the fundus by ophthalmoscopy, after sends the patient to get a Retinography. Sometimes, these retinography are not of good quality. This paper show the implementation of a digital tool that facilitates to ophthalmologist provide better patient diagnosis suffering from diabetic retinopathy, informing them that type of retinopathy has and to what degree of severity is find . This tool develops an algorithm in Matlab based on Gabor transform and in the application of digital filters to provide better and higher quality of retinography. The performance of algorithm has been compared with conventional methods obtaining resulting filtered images with better contrast and higher.

  7. Comparison of optic area measurement using fundus photography and optical coherence tomography between optic nerve head drusen and control subjects.

    Science.gov (United States)

    Flores-Rodríguez, Patricia; Gili, Pablo; Martín-Ríos, María Dolores; Grifol-Clar, Eulalia

    2013-03-01

    To compare optic disc area measurement between optic nerve head drusen (ONHD) and control subjects using fundus photography, time-domain optical coherence tomography (TD-OCT) and spectral-domain optical coherence tomography (SD-OCT). We also made a comparison between each of the three techniques. We performed our study on 66 eyes (66 patients) with ONHD and 70 healthy control subjects (70 controls) with colour ocular fundus photography at 20º (Zeiss FF 450 IR plus), TD-OCT (Stratus OCT) with the Fast Optic Disc protocol and SD-OCT (Cirrus OCT) with the Optic Disc Cube 200 × 200 protocol for measurement of the optic disc area. The measurements were made by two observers and in each measurement a correction of the image magnification factor was performed. Measurement comparison using the Student's t-test/Mann-Whitney U test, the intraclass correlation coefficient, Pearson/Spearman rank correlation coefficient and the Bland-Altman plot was performed in the statistical analysis. Mean and standard deviation (SD) of the optic disc area in ONHD and in controls was 2.38 (0.54) mm(2) and 2.54 (0.42) mm(2), respectively with fundus photography; 2.01 (0.56) mm(2) and 1.66 (0.37) mm(2), respectively with TD-OCT, and 2.03 (0.49) mm(2) and 1.75 (0.38) mm(2), respectively with SD-OCT. In ONHD and controls, repeatability of optic disc area measurement was excellent with fundus photography and optical coherence tomography (TD-OCT and SD-OCT), but with a low degree of agreement between both techniques. Optic disc area measurement is smaller in ONHD compared to healthy subjects with fundus photography, unlike time-domain and spectral-domain optical coherence tomography in which the reverse is true. Both techniques offer good repeatability, but a low degree of correlation and agreement, which means that optic disc area measurement is not interchangeable or comparable between techniques. Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  8. Effect of isoproterenol, phenylephrine, and sodium nitroprusside on fundus pulsations in healthy volunteers.

    Science.gov (United States)

    Schmetterer, L; Wolzt, M; Salomon, A; Rheinberger, A; Unfried, C; Zanaschka, G; Fercher, A F

    1996-03-01

    Recently a laser interferometric method for topical measurement of fundus pulsations has been developed. Fundus pulsations in the macular region are caused by the inflow and outflow of blood into the choroid. The purpose of this work was to study the influence of a peripheral vasoconstricting (the alpha 1 adrenoceptor agonist phenylephrine), a predominantly positive inotropic (the non-specific beta adrenoceptor agonist isoproterenol), and a non-specific vasodilating (sodium nitroprusside) model drug on ocular fundus pulsations to determine reproducibility and sensitivity of the method. In a double masked randomised crossover study the drugs were administered in stepwise increasing doses to 10 male and nine female healthy volunteers. Systemic haemodynamic variables and fundus pulsations were measured at all infusion steps. Fundus pulsation increased during infusion of isoproterenol with statistical significance versus baseline at the lowest dose of 0.1 microgram/min. Neither peripheral vasoconstriction nor peripheral vasodilatation affected the ocular fundus pulsations. Measurements of fundus pulsations is a highly reproducible method in healthy subjects with low ametropy. Changes of local pulsatile ocular blood flow were detectable with our method following the infusion of isoproterenol. As systemic pharmacological vasodilatation or vasoconstriction did not change fundus pulsations, further experimental work has to be done to evaluate the sensitivity of the laser interferometric fundus pulsation measurement in various eye diseases.

  9. Comparative study of the polaroid and digital non-mydriatic cameras in the detection of referrable diabetic retinopathy in Australia.

    Science.gov (United States)

    Phiri, R; Keeffe, J E; Harper, C A; Taylor, H R

    2006-08-01

    To show that the non-mydriatic retinal camera (NMRC) using polaroid film is as effective as the NMRC using digital imaging in detecting referrable retinopathy. A series of patients with diabetes attending the eye out-patients department at the Royal Victorian Eye and Ear Hospital had single-field non-mydriatic fundus photographs taken using first a digital and then a polaroid camera. Dilated 30 degrees seven-field stereo fundus photographs were then taken of each eye as the gold standard. The photographs were graded in a masked fashion. Retinopathy levels were defined using the simplified Wisconsin Grading system. We used the kappa statistics for inter-reader and intrareader agreement and the generalized linear model to derive the odds ratio. There were 196 participants giving 325 undilated retinal photographs. Of these participants 111 (57%) were males. The mean age of the patients was 68.8 years. There were 298 eyes with all three sets of photographs from 154 patients. The digital NMRC had a sensitivity of 86.2%[95% confidence interval (CI) 65.8, 95.3], whilst the polaroid NMRC had a sensitivity of 84.1% (95% CI 65.5, 93.7). The specificities of the two cameras were identical at 71.2% (95% CI 58.8, 81.1). There was no difference in the ability of the polaroid and digital camera to detect referrable retinopathy (odds ratio 1.06, 95% CI 0.80, 1.40, P = 0.68). This study suggests that non-mydriatic retinal photography using polaroid film is as effective as digital imaging in the detection of referrable retinopathy in countries such as the USA and Australia or others that use the same criterion for referral.

  10. Nonmydriatic Ocular Fundus Photography in the Emergency Department: How It Can Benefit Neurologists.

    Science.gov (United States)

    Bruce, Beau B

    2015-10-01

    Examination of the ocular fundus is a critical aspect of the neurologic examination. For example, in patients with headache the ocular fundus examination is needed to uncover "red flags" suggestive of secondary etiologies. However, ocular fundus examination is infrequently and poorly performed in clinical practice. Nonmydriatic ocular fundus photography provides an alternative to direct ophthalmoscopy that has been studied as part of the Fundus Photography versus Ophthalmoscopy Trial Outcomes in the Emergency Department (FOTO-ED) Study. Herein, the results of the FOTO-ED study are reviewed with a particular focus on the study's implications for the acute care of patients presenting with headache and focal neurologic deficits. In headache patients, not only optic disc edema and optic disc pallor were observed as would be expected, but also a large number of abnormalities associated with hypertension. Based upon subjects with focal neurologic deficits, the FOTO-ED study suggests that the ocular fundus examination may assist with the triage of patients presenting with suspected transient ischemic attack. Continued advances in the ease and portability of nonmydriatic fundus photography will hopefully help to restore ocular fundus examination as a routinely performed component of all neurologic examinations. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  11. Prevention of increased abnormal fundus autofluorescence with blue light-filtering intraocular lenses.

    Science.gov (United States)

    Nagai, Hiroyuki; Hirano, Yoshio; Yasukawa, Tsutomu; Morita, Hiroshi; Nozaki, Miho; Wolf-Schnurrbusch, Ute; Wolf, Sebastian; Ogura, Yuichiro

    2015-09-01

    To observe changes in fundus autofluorescence 2 years after implantation of blue light-filtering (yellow-tinted) and ultraviolet light-filtering (colorless) intraocular lenses (IOLs). Department of Ophthalmology and Visual Science, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan, and the Department of Ophthalmology, University of Bern, Bern, Switzerland. Prospective comparative observational study. Patients were enrolled who had cataract surgery with implantation of a yellow-tinted or colorless IOL and for whom images were obtained on which the fundus autofluorescence was measurable using the Heidelberg Retina Angiogram 2 postoperatively. The fundus autofluorescence in the images was classified into 8 abnormal patterns based on the classification of the International Fundus Autofluorescence Classification Group, The presence of normal fundus autofluorescence, geographic atrophy, and wet age-related macular degeneration (AMD) also was recorded. The fundus findings at baseline and 2 years postoperatively were compared. Fifty-two eyes with a yellow-tinted IOL and 79 eyes with a colorless IOL were included. Abnormal fundus autofluorescence did not develop or increase in the yellow-tinted IOL group; however, progressive abnormal fundus autofluorescence developed or increased in 12 eyes (15.2%) in the colorless IOL group (P = .0016). New drusen, geographic atrophy, and choroidal neovascularization were observed mainly in the colorless IOL group. The incidence of AMD was statistically significantly higher in the colorless IOL group (P = .042). Two years after cataract surgery, significant differences were seen in the progression of abnormal fundus autofluorescence between the 2 groups. The incidence of AMD was lower in eyes with a yellow-tinted IOL. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Long-term fundus changes in acquired partial lipodystrophy.

    Science.gov (United States)

    Jansen, Joyce; Delaere, Lien; Spielberg, Leigh; Leys, Anita

    2013-11-18

    We describe long-term fundus changes in a patient with partial lipodystrophy (PL). Retinal pigment alterations, drusen and subretinal neovascularisation were seen without evidence for membranoproliferative glomerulonephritis. Fundus alterations similar to those seen in age-related macular degeneration can occur at an earlier age in patients with PL, even without renal disease. Dysregulation of an alternative complement pathway with low serum levels of C3 has been implicated as a pathogenetic mechanism.

  13. Fundus autofluorescence in retinal artery occlusion: A more precise diagnosis.

    Science.gov (United States)

    Bacquet, J-L; Sarov-Rivière, M; Denier, C; Querques, G; Riou, B; Bonin, L; Barreau, E; Labetoulle, M; Rousseau, A

    2017-10-01

    Retinal artery occlusion (RAO) is a medical emergency associated with a high risk of cerebral vascular accident and other cardiovascular events. Among patients with non-arteritic RAO, a retinal embolus is observed in approximately 40% of cases. Fundus examination and retinography are not reliable to predict the nature of the emboli. We report three consecutive cases of central and branch RAO that were investigated with fundus autofluorescence, fluorescein angiography and color retinal photographs. All patients underwent complete neurological and cardiovascular workups, with brain imaging, cardiac Doppler ultrasound, carotid Dopplers and Holter ECG's, to determine the underlying mechanism of retinal embolism. In the three cases, aged 77.7±4 years (2 women and 1 man), fundus autofluorescence demonstrated hyperautofluorescent emboli. In two cases, it allowed visualization of emboli that were not detected with fundus examination or retinography. The cardiovascular work-up demonstrated atheromatous carotid or aortic plaques in all patients. In one case, it permitted the diagnosis of RAO. Two of the three cases were considered to be of atherosclerotic origin and one of undefined origin. Fundus autofluorescence may help to detect and characterize retinal emboli. Since lipofuscin, which is present in large quantity in atherosclerotic plaques, is the main fluorophore detected with fundus autofluorescence, this non-invasive and simple examination may give information about the underlying mechanism of retinal embolism, and thus impact the etiologic assessment of RAO. Additional studies are necessary to confirm this potential role of autofluorescence. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. Personal identification based on blood vessels of retinal fundus images

    Science.gov (United States)

    Fukuta, Keisuke; Nakagawa, Toshiaki; Hayashi, Yoshinori; Hatanaka, Yuji; Hara, Takeshi; Fujita, Hiroshi

    2008-03-01

    Biometric technique has been implemented instead of conventional identification methods such as password in computer, automatic teller machine (ATM), and entrance and exit management system. We propose a personal identification (PI) system using color retinal fundus images which are unique to each individual. The proposed procedure for identification is based on comparison of an input fundus image with reference fundus images in the database. In the first step, registration between the input image and the reference image is performed. The step includes translational and rotational movement. The PI is based on the measure of similarity between blood vessel images generated from the input and reference images. The similarity measure is defined as the cross-correlation coefficient calculated from the pixel values. When the similarity is greater than a predetermined threshold, the input image is identified. This means both the input and the reference images are associated to the same person. Four hundred sixty-two fundus images including forty-one same-person's image pairs were used for the estimation of the proposed technique. The false rejection rate and the false acceptance rate were 9.9×10 -5% and 4.3×10 -5%, respectively. The results indicate that the proposed method has a higher performance than other biometrics except for DNA. To be used for practical application in the public, the device which can take retinal fundus images easily is needed. The proposed method is applied to not only the PI but also the system which warns about misfiling of fundus images in medical facilities.

  15. Non-mydriatic ocular fundus photography in the emergency department: how it can benefit neurologists

    Science.gov (United States)

    Bruce, Beau B.

    2016-01-01

    Examination of the ocular fundus is a critical aspect of the neurological examination. For example, in patients with headache the ocular fundus examination is needed to uncover “red flags” suggestive of secondary etiologies. However, ocular fundus examination is infrequently and poorly performed in clinical practice. Non-mydriatic ocular fundus photography provides an alternative to direct ophthalmoscopy that has been studied as part of the Fundus photography vs. Ophthalmoscopy Trial Outcomes in the Emergency Department (FOTO-ED) study. Herein, we review the results of the FOTO-ED study with a particular focus on the study's implications for the acute care of patients presenting with headache and focal neurologic deficits. In headache patients, we not only observed optic disc edema and optic disc pallor as would be expected, but also a large number of abnormalities associated with hypertension. Based upon subjects with focal neurological deficits, the FOTO-ED study suggests that the ocular fundus examination may assist with the triage of patients presenting with suspected transient ischemic attack. Continued advances in the ease and portability of non-mydriatic fundus photography will hopefully help to restore ocular fundus examination as a routinely performed component of all neurological examinations. PMID:26444394

  16. Fundus autofluorescence: applications and perspectives.

    Science.gov (United States)

    Cuba, J; Gómez-Ulla, F

    2013-02-01

    To describe the findings of the study of autofluorescence of the different retinal diseases included in the study. To determine in which diseases autofluorescence may be more, or just as, useful as fluorescein angiography (FAG) in terms of diagnostic information. We studied the retinal autofluorescence of 123 eyes of 93 patients, including various diseases of the eye fundus. In all cases we explored the fundus, retinal autofluorescence, and, if indicated, FAG was performed. Analysis of the autofluorescence was performed using the Heidelberg Retina angiography Angiograph 2 (HRA2) Heidelberg Engineering (Germany). The autofluorescence information provided was equal or better (than FAG) in: 68.18% of cases of macular edema, 50% of pigment epithelium detachments, 100% of pigment epithelium atrophies, 100% of central serous chorioretinopathy; 55.55% of choroidal neovascularization, 100% of retinal dystrophies with deposition of lipofuscin, 100% of hard exudates and pre-retinal hemorrhages. Autofluorescence is a quick and non-invasive examination method, comfortable for both patient and examiner, and with a very short learning curve. It provides diagnostic information about many eye fundus diseases. While more studies and more experience with its use are needed, its interest lies in the possibility of avoiding the performing of angiography in patients with these diseases, and in the additional information autofluorescence provides about the functional situation of cells and retinal pigments. Copyright © 2011 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  17. Analysis of Fundus Photography and Fluorescein Angiography in Nonarteritic Anterior Ischemic Optic Neuropathy and Optic Neuritis.

    Science.gov (United States)

    Kim, Min Kyung; Kim, Ungsoo Samuel

    2016-08-01

    We evaluated fundus and fluorescein angiography (FAG) findings and characteristics that can help distinguish nonarteritic anterior ischemic optic neuropathy (NAION) from optic neuritis (ON). Twenty-three NAION patients and 17 ON with disc swelling patients were enrolled in this study. We performed fundus photography and FAG. The disc-swelling pattern, hyperemia grade, presence of splinter hemorrhages, cotton-wool spots, artery/vein ratio and degree of focal telangiectasia were investigated. The FAG findings for each patient were compared with respect to the following features: the pattern of disc leakage in the early phase, arteriovenous (artery/vein) transit time (second), and the presence and pattern of the filling delay. Cotton-wool spots, focal telangiectasia, and venous congestion were more common in the affected eyes of NAION patients. Upon FAG, 76.5% of the patients in the ON group exhibited normal choroidal circulation. However, 56.5% of patients in the NAION group demonstrated abnormal filling defects, such as peripapillary, generalized, or watershed zone filling delays. Fundus findings, including cotton-wool spots, focal telangiectasia, and venous congestion in the affected eye, may be clues that can be used to diagnose NAION. In addition, choroidal insufficiencies on FAG could be also helpful in differentiating NAION from ON.

  18. Hyperspectral fundus imager

    Science.gov (United States)

    Truitt, Paul W.; Soliz, Peter; Meigs, Andrew D.; Otten, Leonard John, III

    2000-11-01

    A Fourier Transform hyperspectral imager was integrated onto a standard clinical fundus camera, a Zeiss FF3, for the purposes of spectrally characterizing normal anatomical and pathological features in the human ocular fundus. To develop this instrument an existing FDA approved retinal camera was selected to avoid the difficulties of obtaining new FDA approval. Because of this, several unusual design constraints were imposed on the optical configuration. Techniques to calibrate the sensor and to define where the hyperspectral pushbroom stripe was located on the retina were developed, including the manufacturing of an artificial eye with calibration features suitable for a spectral imager. In this implementation the Fourier transform hyperspectral imager can collect over a hundred 86 cm-1 spectrally resolved bands with 12 micro meter/pixel spatial resolution within the 1050 nm to 450 nm band. This equates to 2 nm to 8 nm spectral resolution depending on the wavelength. For retinal observations the band of interest tends to lie between 475 nm and 790 nm. The instrument has been in use over the last year successfully collecting hyperspectral images of the optic disc, retinal vessels, choroidal vessels, retinal backgrounds, and macula diabetic macular edema, and lesions of age-related macular degeneration.

  19. Digital Elevation Model (DEM) file of topographic elevations for the Death Valley region of southern Nevada and southeastern California processed from US Geological Survey 1-degree Digital Elevation Model data files

    International Nuclear Information System (INIS)

    Turner, A.K.; D'Agnese, F.A.; Faunt, C.C.

    1996-01-01

    Elevation data have been compiled into a digital data base for an ∼100,000-km 2 area of the southern Great Basin, the Death Valley region of southern Nevada, and SE Calif., located between lat 35 degree N, long 115 degree W, and lat 38 degree N, long 118 degree W. This region includes the Nevada Test Site, Yucca Mountain, and adjacent parts of southern Nevada and eastern California and encompasses the Death Valley regional ground-water system. Because digital maps are often useful for applications other than that for which they were originally intended, and because the area corresponds to a region under continuing investigation by several groups, these digital files are being released by USGS

  20. Fundus autofluorescence and the bisretinoids of retina.

    Science.gov (United States)

    Sparrow, Janet R; Wu, Yalin; Nagasaki, Takayuki; Yoon, Kee Dong; Yamamoto, Kazunori; Zhou, Jilin

    2010-11-01

    Imaging of the human fundus of the eye with excitation wavelengths in the visible spectrum reveals a natural autofluorescence, that in a healthy retina originates primarily from the bisretinoids that constitute the lipofuscin of retinal pigment epithelial (RPE) cells. Since the intensity and distribution of fundus autofluorescence is altered in the presence of retinal disease, we have examined the fluorescence properties of the retinal bisretinoids with a view to aiding clinical interpretations. As is also observed for fundus autofluorescence, fluorescence emission from RPE lipofuscin was generated with a wide range of exciting wavelengths; with increasing excitation wavelength, the emission maximum shifted towards longer wavelengths and spectral width was decreased. These features are consistent with fluorescence generation from a mixture of compounds. While the bisretinoids that constitute RPE lipofuscin all fluoresced with maxima that were centered around 600 nm, fluorescence intensities varied when excited at 488 nm, the excitation wavelength utilized for fundus autofuorescence imaging. For instance the fluorescence efficiency of the bisretinoid A2-dihydropyridine-phosphatidylethanolamine (A2-DHP-PE) was greater than A2E and relative to both of the latter, all-trans-retinal dimer-phosphatidylethanolamine was weakly fluorescent. On the other hand, certain photooxidized forms of the bisretinoids present in both RPE and photoreceptor cells were more strongly fluorescent than the parent compound. We also sought to evaluate whether diffuse puncta of autofluorescence observed in some retinal disorders of monogenic origin are attributable to retinoid accumulation. However, two retinoids of the visual cycle, all-trans-retinyl ester and all-trans-retinal, did not exhibit fluorescence at 488 nm excitation.

  1. The Role of Fundus Autofluorescence in Late-Onset Retinitis Pigmentosa (LORP) Diagnosis

    Science.gov (United States)

    Lee, Tamara J.; Hwang, John C.; Chen, Royce W. S.; Lima, Luiz H.; Wang, Nan-Kai; Tosi, Joaquin; Freund, K. Bailey; Yannuzzi, Lawrence A.; Tsang, Stephen H.

    2015-01-01

    Purpose To demonstrate the utility and characteristics of fundus autofluorescence in late-onset retinitis pigmentosa. Methods Observational case series. Patients diagnosed with late-onset retinitis pigmentosa were identified retrospectively in an institutional setting. Twelve eyes of six patients were identified and medical records were reviewed. Results All patients presented with slowly progressive peripheral field loss and initial clinical examination revealed only subtle retinal changes. There was a notable lack of intraretinal pigment migration in all patients. Five out of six patients underwent magnetic resonance imaging of the brain to rule out intracranial processes and all were referred from another ophthalmologist for further evaluation. Fundus autofluorescence was ultimately employed in all patients and revealed more extensive retinal pathology than initially appreciated on clinical examination. Fundus autofluorescence directed the workup toward a retinal etiology in all cases and led to the eventual diagnosis of late-onset retinitis pigmentosa through electroretinogram testing. Conclusion Fundus autofluorescence may be a more sensitive marker for retinal pathology than stereo fundus biomicroscopy alone in late-onset retinitis pigmentosa. Early use of fundus autofluorescence imaging in the evaluation of patients with subtle retinal lesions and complaints of peripheral field loss may be an effective strategy for timely and cost-efficient diagnosis. PMID:23899229

  2. Adaptive optics scanning laser ophthalmoscopy in fundus imaging, a review and update

    Directory of Open Access Journals (Sweden)

    Bing Zhang

    2017-11-01

    Full Text Available Adaptive optics scanning laser ophthalmoscopy (AO-SLO has been a promising technique in funds imaging with growing popularity. This review firstly gives a brief history of adaptive optics (AO and AO-SLO. Then it compares AO-SLO with conventional imaging methods (fundus fluorescein angiography, fundus autofluorescence, indocyanine green angiography and optical coherence tomography and other AO techniques (adaptive optics flood-illumination ophthalmoscopy and adaptive optics optical coherence tomography. Furthermore, an update of current research situation in AO-SLO is made based on different fundus structures as photoreceptors (cones and rods, fundus vessels, retinal pigment epithelium layer, retinal nerve fiber layer, ganglion cell layer and lamina cribrosa. Finally, this review indicates possible research directions of AO-SLO in future.

  3. Hypertensive retinopathy identification through retinal fundus image using backpropagation neural network

    Science.gov (United States)

    Syahputra, M. F.; Amalia, C.; Rahmat, R. F.; Abdullah, D.; Napitupulu, D.; Setiawan, M. I.; Albra, W.; Nurdin; Andayani, U.

    2018-03-01

    Hypertension or high blood pressure can cause damage of blood vessels in the retina of eye called hypertensive retinopathy (HR). In the event Hypertension, it will cause swelling blood vessels and a decrese in retina performance. To detect HR in patients body, it is usually performed through physical examination of opthalmoscope which is still conducted manually by an ophthalmologist. Certainly, in such a manual manner, takes a ong time for a doctor to detetct HR on aa patient based on retina fundus iamge. To overcome ths problem, a method is needed to identify the image of retinal fundus automatically. In this research, backpropagation neural network was used as a method for retinal fundus identification. The steps performed prior to identification were pre-processing (green channel, contrast limited adapative histogram qualization (CLAHE), morphological close, background exclusion, thresholding and connected component analysis), feature extraction using zoning. The results show that the proposed method is able to identify retinal fundus with an accuracy of 95% with maximum epoch of 1500.

  4. Is screening with digital imaging using one retinal view adequate?

    Science.gov (United States)

    Herbert, H M; Jordan, K; Flanagan, D W

    2003-05-01

    To compare the detection of diabetic retinopathy from digital images with slit-lamp biomicroscopy, and to determine whether British Diabetic Association (BDA) screening criteria are attained (>80% sensitivity, >95% specificity, &fashion. A single 45 degrees fundus image was obtained using the nonmydriatic digital camera. Each patient subsequently underwent slit-lamp biomicroscopy and diabetic retinopathy grading by a consultant ophthalmologist. Diabetic retinopathy and maculopathy was graded according to the Early Treatment of Diabetic Retinopathy Study. A total of 145 patients (288 eyes) were identified for screening. Of these, 26% of eyes had diabetic retinopathy, and eight eyes (3%) had sight-threatening diabetic retinopathy requiring treatment. The sensitivity for detection of any diabetic retinopathy was 38% and the specificity 95%. There was a 4% technical failure rate. There were 42/288 false negatives and 10/288 false positives. Of the 42 false negatives, 18 represented diabetic maculopathy, 20 represented peripheral diabetic retinopathy and four eyes had both macular and peripheral changes. Three eyes in the false-negative group (1% of total eyes) had sight-threatening retinopathy. There was good concordance between the two consultants (79% agreement on slit-lamp biomicroscopy and 84% on digital image interpretation). The specificity value and technical failure rate compare favourably with BDA guidelines. The low sensitivity for detection of any retinopathy reflects failure to detect minimal maculopathy and retinopathy outside the 45 degrees image. This could be improved by an additional nasal image and careful evaluation of macular images with a low threshold for slit-lamp biomicroscopy if image quality is poor.

  5. A Portable, Inexpensive, Nonmydriatic Fundus Camera Based on the Raspberry Pi® Computer

    Directory of Open Access Journals (Sweden)

    Bailey Y. Shen

    2017-01-01

    Full Text Available Purpose. Nonmydriatic fundus cameras allow retinal photography without pharmacologic dilation of the pupil. However, currently available nonmydriatic fundus cameras are bulky, not portable, and expensive. Taking advantage of recent advances in mobile technology, we sought to create a nonmydriatic fundus camera that was affordable and could be carried in a white coat pocket. Methods. We built a point-and-shoot prototype camera using a Raspberry Pi computer, an infrared-sensitive camera board, a dual infrared and white light light-emitting diode, a battery, a 5-inch touchscreen liquid crystal display, and a disposable 20-diopter condensing lens. Our prototype camera was based on indirect ophthalmoscopy with both infrared and white lights. Results. The prototype camera measured 133mm×91mm×45mm and weighed 386 grams. The total cost of the components, including the disposable lens, was $185.20. The camera was able to obtain good-quality fundus images without pharmacologic dilation of the pupils. Conclusion. A fully functional, inexpensive, handheld, nonmydriatic fundus camera can be easily assembled from a relatively small number of components. With modest improvements, such a camera could be useful for a variety of healthcare professionals, particularly those who work in settings where a traditional table-mounted nonmydriatic fundus camera would be inconvenient.

  6. Fundus albipunctatus associated with compound heterozygous mutations in RPE65

    DEFF Research Database (Denmark)

    Schatz, Patrik; Preising, Markus; Lorenz, Birgit

    2011-01-01

    To describe a family with an 18-year-old woman with fundus albipunctatus and compound heterozygous mutations in RPE65 whose unaffected parents and 1 female sibling harbored single heterozygous RPE65 mutations.......To describe a family with an 18-year-old woman with fundus albipunctatus and compound heterozygous mutations in RPE65 whose unaffected parents and 1 female sibling harbored single heterozygous RPE65 mutations....

  7. Bright Retinal Lesions Detection using Colour Fundus Images Containing Reflective Features

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Karnowski, Thomas Paul [ORNL; Chaum, Edward [ORNL; Meriaudeau, Fabrice [ORNL; Tobin Jr, Kenneth William [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK)

    2009-01-01

    In the last years the research community has developed many techniques to detect and diagnose diabetic retinopathy with retinal fundus images. This is a necessary step for the implementation of a large scale screening effort in rural areas where ophthalmologists are not available. In the United States of America, the incidence of diabetes is worryingly increasing among the young population. Retina fundus images of patients younger than 20 years old present a high amount of reflection due to the Nerve Fibre Layer (NFL), the younger the patient the more these reflections are visible. To our knowledge we are not aware of algorithms able to explicitly deal with this type of reflection artefact. This paper presents a technique to detect bright lesions also in patients with a high degree of reflective NFL. First, the candidate bright lesions are detected using image equalization and relatively simple histogram analysis. Then, a classifier is trained using texture descriptor (Multi-scale Local Binary Patterns) and other features in order to remove the false positives in the lesion detection. Finally, the area of the lesions is used to diagnose diabetic retinopathy. Our database consists of 33 images from a telemedicine network currently developed. When determining moderate to high diabetic retinopathy using the bright lesions detected the algorithm achieves a sensitivity of 100% at a specificity of 100% using hold-one-out testing.

  8. Application of RetCamⅡ in the screening of neonatal fundus disease

    Directory of Open Access Journals (Sweden)

    Zhi-Gang Xiao

    2013-08-01

    Full Text Available AIM: To investigate the safe and reliable examination method for neonatal fundus screening.METHODS: Fundus information of 2 836 neonates performed by RetCamⅡ in our hospital from January 1, 2012 to December 31, 2012 were retrospectively analyzed, including 1 625 cases(57.30%of premature infants which were first examined 1-4 weeks after birth and 1 211 cases(42.70%of term infants which were first examined within 4 weeks after birth.RESULTS: Totally 454 cases of abnormalfundus were found, including 207 cases(12.74%of retinopathy of prematurity(ROP, ROPⅠ in 118 cases(57%, ROPⅡ in 58 cases(28.02%, ROPⅢ in 23 cases(11.11%, ROPⅣ in 8 cases(3.86%, no case of ROPV. A total of 247(20.40%term infants had abnormal fundus, of which 68 cases(27.53%were developmental or hereditary disease, retinoblastoma in 1 case(0.40%, retinal hemorrhage in 102 cases(41.30%, retinal exudative changes in 68 cases(27.53%, optic atrophy in 5 cases(2.02%and optic disc edema in 3 cases(1.21%.CONCLUSION: Neonatal fundus diseases were so various and harmful that early screening should be attended to. Premature infants and term infants with high risk are treated as focus group of fundus screening and RetCamII examination is safe and effective.

  9. Contact-free trans-pars-planar illumination enables snapshot fundus camera for nonmydriatic wide field photography.

    Science.gov (United States)

    Wang, Benquan; Toslak, Devrim; Alam, Minhaj Nur; Chan, R V Paul; Yao, Xincheng

    2018-06-08

    In conventional fundus photography, trans-pupillary illumination delivers illuminating light to the interior of the eye through the peripheral area of the pupil, and only the central part of the pupil can be used for collecting imaging light. Therefore, the field of view of conventional fundus cameras is limited, and pupil dilation is required for evaluating the retinal periphery which is frequently affected by diabetic retinopathy (DR), retinopathy of prematurity (ROP), and other chorioretinal conditions. We report here a nonmydriatic wide field fundus camera employing trans-pars-planar illumination which delivers illuminating light through the pars plana, an area outside of the pupil. Trans-pars-planar illumination frees the entire pupil for imaging purpose only, and thus wide field fundus photography can be readily achieved with less pupil dilation. For proof-of-concept testing, using all off-the-shelf components a prototype instrument that can achieve 90° fundus view coverage in single-shot fundus images, without the need of pharmacologic pupil dilation was demonstrated.

  10. Imperceptible watermarking for security of fundus images in tele-ophthalmology applications and computer-aided diagnosis of retina diseases.

    Science.gov (United States)

    Singh, Anushikha; Dutta, Malay Kishore

    2017-12-01

    The authentication and integrity verification of medical images is a critical and growing issue for patients in e-health services. Accurate identification of medical images and patient verification is an essential requirement to prevent error in medical diagnosis. The proposed work presents an imperceptible watermarking system to address the security issue of medical fundus images for tele-ophthalmology applications and computer aided automated diagnosis of retinal diseases. In the proposed work, patient identity is embedded in fundus image in singular value decomposition domain with adaptive quantization parameter to maintain perceptual transparency for variety of fundus images like healthy fundus or disease affected image. In the proposed method insertion of watermark in fundus image does not affect the automatic image processing diagnosis of retinal objects & pathologies which ensure uncompromised computer-based diagnosis associated with fundus image. Patient ID is correctly recovered from watermarked fundus image for integrity verification of fundus image at the diagnosis centre. The proposed watermarking system is tested in a comprehensive database of fundus images and results are convincing. results indicate that proposed watermarking method is imperceptible and it does not affect computer vision based automated diagnosis of retinal diseases. Correct recovery of patient ID from watermarked fundus image makes the proposed watermarking system applicable for authentication of fundus images for computer aided diagnosis and Tele-ophthalmology applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. A Case of Fundus Oculi Albinoticus Diagnosed as Angelman Syndrome by Genetic Testing

    Directory of Open Access Journals (Sweden)

    Yurie Fukiyama

    2018-02-01

    Full Text Available Purpose: To report a case of fundus oculi albinoticus diagnosed as Angelman syndrome (AS via genetic testing. Case Report: This study reports on a 4-year-old boy. Since he had been having respiratory disturbance since birth, he underwent a complete physical examination to investigate the cause. The results indicated that he had various brain congenital abnormalities, such as a thin corpus callosum, as well as hydronephrosis, an atrial septal defect, and skin similar to patients with fundus oculi albinoticus. Examination revealed bilateral fundus oculi albinoticus, mild iridic hypopigmentation, optic atrophy, and poor visual tracking. Genetic testing revealed a deletion in the Prader-Willi syndrome/AS region on chromosome 15, and together with the results of methylation analysis, his condition was diagnosed as AS. Follow-up examinations revealed no change in the fundus oculi albinoticus and optic atrophy, nor did they indicate poor visual tracking. Conclusions: When fundus oculi albinoticus and optic atrophy are observed in patients with multiple malformations, AS should be considered as a differential diagnosis.

  12. Fundus reflectance : historical and present ideas

    NARCIS (Netherlands)

    Berendschot, T.T.J.M.; Delint, P.J.; Norren, D. van

    2003-01-01

    In 1851 Helmholtz introduced the ophthalmoscope. The instrument allowed the observation of light reflected at the fundus. The development of this device was one of the major advancements in ophthalmology. Yet ophthalmoscopy allows only qualitative observation of the eye. Since 1950 attempts were

  13. Adaptive optics fundus images of cone photoreceptors in the macula of patients with retinitis pigmentosa

    Directory of Open Access Journals (Sweden)

    Tojo N

    2013-01-01

    Full Text Available Naoki Tojo, Tomoko Nakamura, Chiharu Fuchizawa, Toshihiko Oiwake, Atsushi HayashiDepartment of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, JapanBackground: The purpose of this study was to examine cone photoreceptors in the macula of patients with retinitis pigmentosa using an adaptive optics fundus camera and to investigate any correlations between cone photoreceptor density and findings on optical coherence tomography and fundus autofluorescence.Methods: We examined two patients with typical retinitis pigmentosa who underwent ophthalmological examination, including measurement of visual acuity, and gathering of electroretinographic, optical coherence tomographic, fundus autofluorescent, and adaptive optics fundus images. The cone photoreceptors in the adaptive optics images of the two patients with retinitis pigmentosa and five healthy subjects were analyzed.Results: An abnormal parafoveal ring of high-density fundus autofluorescence was observed in the macula in both patients. The border of the ring corresponded to the border of the external limiting membrane and the inner segment and outer segment line in the optical coherence tomographic images. Cone photoreceptors at the abnormal parafoveal ring were blurred and decreased in the adaptive optics images. The blurred area corresponded to the abnormal parafoveal ring in the fundus autofluorescence images. Cone densities were low at the blurred areas and at the nasal and temporal retina along a line from the fovea compared with those of healthy controls. The results for cone spacing and Voronoi domains in the macula corresponded with those for the cone densities.Conclusion: Cone densities were heavily decreased in the macula, especially at the parafoveal ring on high-density fundus autofluorescence in both patients with retinitis pigmentosa. Adaptive optics images enabled us to observe in vivo changes in the cone photoreceptors of

  14. Use of fundus autofluorescence images to predict geographic atrophy progression.

    Science.gov (United States)

    Bearelly, Srilaxmi; Khanifar, Aziz A; Lederer, David E; Lee, Jane J; Ghodasra, Jason H; Stinnett, Sandra S; Cousins, Scott W

    2011-01-01

    Fundus autofluorescence imaging has been shown to be helpful in predicting progression of geographic atrophy (GA) secondary to age-related macular degeneration. We assess the ability of fundus autofluorescence imaging to predict rate of GA progression using a simple categorical scheme. Subjects with GA secondary to age-related macular degeneration with fundus autofluorescence imaging acquired at least 12 months apart were included. Rim area focal hyperautofluorescence was defined as percentage of the 500-μm-wide margin bordering the GA that contained increased autofluorescence. Rim area focal hyperautofluorescence on baseline fundus autofluorescence images was assessed and categorized depending on the extent of rim area focal hyperautofluorescence (Category 1: ≤33%; Category 2: between 33 and 67%; Category 3: ≥67%). Total GA areas at baseline and follow-up were measured to calculate change in GA progression. Forty-five eyes of 45 subjects were included; average duration of follow-up was 18.5 months. Median growth rates differed among categories of baseline rim area focal hyperautofluorescence (P = 0.01 among Categories 1, 2, and 3; P = 0.008 for Category 1 compared with Category 3, Jonckheere-Terpstra test). A simple categorical scheme that stratifies the amount of increased autofluorescence in the 500-μm margin bordering GA may be used to differentiate faster and slower progressors.

  15. Fundus Findings in Dengue Fever: A Case Report

    Directory of Open Access Journals (Sweden)

    Berna Şahan

    2015-10-01

    Full Text Available Dengue fever is a flavivirus infection transmitted through infected mosquitoes, and is endemic in Southeast Asia, Central and South America, the Pacific, Africa and the Eastern Mediterranean region. A 41-year-old male patient had visual impairment after travelling to Thailand, which is one of the endemic areas. Cotton wool spots were observed on fundus examination. Fundus fluorescein angiography showed minimal vascular leakage from areas near the cotton wool spots and dot hemorrhages in the macula. Dengue fever should be considered in patients with visual complaints who traveled to endemic areas of dengue fever. (Turk J Ophthalmol 2015; 45: 223-225

  16. Analysis of phakic before intraocular lens implantation for fundus examination

    OpenAIRE

    Juan Chen; Zhong-Ping Chen; Rui-Ling Zhu

    2014-01-01

    AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL). To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examina...

  17. Krypton red laser photocoagulation of the ocular fundus. 1982.

    Science.gov (United States)

    Yannuzzi, Lawrence A; Shakin, Jeffrey L

    2012-02-01

    The theoretical rationale, the histopathologic evidence, and the preliminary clinical studies related to krypton red laser (KRL) photocoagulation of the ocular fundus are reviewed. The authors report on their experience with currently available laser systems using this wavelength (647.1 nm) for photocoagulation of retinal vascular proliferative diseases and chorioretinal diseases associated with exudative manifestations. A histopathologic and clinical comparison of argon blue-green laser (ABGL), the pure argon green laser (AGL), and the krypton yellow laser (KYL), with reference to photocoagulation treatment of the ocular fundus is also discussed.

  18. UTILIZATION OF FUNDUS AUTOFLUORESCENCE, SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY, AND ENHANCED DEPTH IMAGING IN THE CHARACTERIZATION OF BIETTI CRYSTALLINE DYSTROPHY IN DIFFERENT STAGES.

    Science.gov (United States)

    Li, Qian; Li, Yang; Zhang, Xiaohui; Xu, Zhangxing; Zhu, Xiaoqing; Ma, Kai; She, Haicheng; Peng, Xiaoyan

    2015-10-01

    To characterize Bietti crystalline dystrophy (BCD) in different stages using multiple imaging modalities. Sixteen participants clinically diagnosed as BCD were included in the retrospective study and were categorized into 3 stages according to fundus photography. Eleven patients were genetically confirmed. Fundus autofluorescence, spectral domain optical coherence tomography, and enhanced depth imaging features of BCD were analyzed. On fundus autofluorescence, the abnormal autofluorescence was shown to enlarge in area and decrease in intensity with stages. Using spectral domain optical coherence tomography, the abnormalities in Stage 1 were observed to localize in outer retinal layers, whereas in Stage 2 and Stage 3, more extensive retinal atrophy was seen. In enhanced depth imaging, the subfoveal choroidal layers were delineated clearly in Stage 1; in Stage 2, destructions were primarily found in the choriocapillaris with associated alterations in the outer vessels; Stage 3 BCD displayed severe choroidal thinning. Choroidal neovascularization and macular edema were exhibited with high incidence. IVS6-8del17bp/inGC of the CYP4V2 gene was the most common mutant allele. Noninvasive fundus autofluorescence, spectral domain optical coherence tomography, and enhanced depth imaging may help to characterize the chorioretinal pathology of BCD at different degrees, and therefore, we propose staging of BCD depending on those methods. Physicians should be cautious of the vision-threatening complications of the disease.

  19. Classification of diabetic retinopathy using fractal dimension analysis of eye fundus image

    Science.gov (United States)

    Safitri, Diah Wahyu; Juniati, Dwi

    2017-08-01

    Diabetes Mellitus (DM) is a metabolic disorder when pancreas produce inadequate insulin or a condition when body resist insulin action, so the blood glucose level is high. One of the most common complications of diabetes mellitus is diabetic retinopathy which can lead to a vision problem. Diabetic retinopathy can be recognized by an abnormality in eye fundus. Those abnormalities are characterized by microaneurysms, hemorrhage, hard exudate, cotton wool spots, and venous's changes. The diabetic retinopathy is classified depends on the conditions of abnormality in eye fundus, that is grade 1 if there is a microaneurysm only in the eye fundus; grade 2, if there are a microaneurysm and a hemorrhage in eye fundus; and grade 3: if there are microaneurysm, hemorrhage, and neovascularization in the eye fundus. This study proposed a method and a process of eye fundus image to classify of diabetic retinopathy using fractal analysis and K-Nearest Neighbor (KNN). The first phase was image segmentation process using green channel, CLAHE, morphological opening, matched filter, masking, and morphological opening binary image. After segmentation process, its fractal dimension was calculated using box-counting method and the values of fractal dimension were analyzed to make a classification of diabetic retinopathy. Tests carried out by used k-fold cross validation method with k=5. In each test used 10 different grade K of KNN. The accuracy of the result of this method is 89,17% with K=3 or K=4, it was the best results than others K value. Based on this results, it can be concluded that the classification of diabetic retinopathy using fractal analysis and KNN had a good performance.

  20. The effects of fundus photography on the multifocal electroretinogram.

    Science.gov (United States)

    Suresh, Sandip; Tienor, Brian J; Smith, Scott D; Lee, Michael S

    2016-02-01

    To determine the effect of flash fundus photography (FFP) on the multifocal electroretinogram (mfERG). Ten subjects underwent mfERG testing on three separate dates. Subjects received either mfERG without FFP, mfERG at 5 and 15 min after FFP, or mfERG at 30 and 45 min after FFP on each date. The FFP groups received 10 fundus photographs followed by mfERG testing, first of the right eye then of the left eye 10 min later. Data were averaged and analyzed in six concentric rings at each time point. Average amplitude and implicit times of the N1, P1, and N2 peaks for each concentric ring at each time point after FFP were compared to baseline. Flash fundus photography did not lead to a significant change of amplitude or implicit times of N1, P1, or N2 at 5 min after light exposure. These findings suggest that it is acceptable to perform mfERG testing without delay after performance of FFP.

  1. Imaging autofluorescence temporal signatures of the human ocular fundus in vivo

    Science.gov (United States)

    Papour, Asael; Taylor, Zachary; Stafsudd, Oscar; Tsui, Irena; Grundfest, Warren

    2015-11-01

    We demonstrate real-time in vivo fundus imaging capabilities of our fluorescence lifetime imaging technology for the first time. This implementation of lifetime imaging uses light emitting diodes to capture full-field images capable of showing direct tissue contrast without executing curve fitting or lifetime calculations. Preliminary results of fundus images are presented, investigating autofluorescence imaging potential of various retina biomarkers for early detection of macular diseases.

  2. The Portable Dynamic Fundus Instrument: Uses in telemedicine and research

    Science.gov (United States)

    Hunter, Norwood; Caputo, Michael; Billica, Roger; Taylor, Gerald; Gibson, C. Robert; Manuel, F. Keith; Mader, Thomas; Meehan, Richard

    1994-01-01

    For years ophthalmic photographs have been used to track the progression of many ocular diseases such as macular degeneration and glaucoma as well as the ocular manifestations of diabetes, hypertension, and hypoxia. In 1987 a project was initiated at the Johnson Space Center (JSC) to develop a means of monitoring retinal vascular caliber and intracranial pressure during space flight. To conduct telemedicine during space flight operations, retinal images would require real-time transmissions from space. Film-based images would not be useful during in-flight operations. Video technology is beneficial in flight because the images may be acquired, recorded, and transmitted to the ground for rapid computer digital image processing and analysis. The computer analysis techniques developed for this project detected vessel caliber changes as small as 3 percent. In the field of telemedicine, the Portable Dynamic Fundus Instrument demonstrates the concept and utility of a small, self-contained video funduscope. It was used to record retinal images during the Gulf War and to transmit retinal images from the Space Shuttle Columbia during STS-50. There are plans to utilize this device to provide a mobile ophthalmic screening service in rural Texas. In the fall of 1993 a medical team in Boulder, Colorado, will transmit real-time images of the retina during remote consultation and diagnosis. The research applications of this device include the capability of operating in remote locations or small, confined test areas. There has been interest shown utilizing retinal imaging during high-G centrifuge tests, high-altitude chamber tests, and aircraft flight tests. A new design plan has been developed to incorporate the video instrumentation into face-mounted goggle. This design would eliminate head restraint devices, thus allowing full maneuverability to the subjects. Further development of software programs will broaden the application of the Portable Dynamic Fundus Instrument in

  3. Adaptive optics fundus images of cone photoreceptors in the macula of patients with retinitis pigmentosa.

    Science.gov (United States)

    Tojo, Naoki; Nakamura, Tomoko; Fuchizawa, Chiharu; Oiwake, Toshihiko; Hayashi, Atsushi

    2013-01-01

    The purpose of this study was to examine cone photoreceptors in the macula of patients with retinitis pigmentosa using an adaptive optics fundus camera and to investigate any correlations between cone photoreceptor density and findings on optical coherence tomography and fundus autofluorescence. We examined two patients with typical retinitis pigmentosa who underwent ophthalmological examination, including measurement of visual acuity, and gathering of electroretinographic, optical coherence tomographic, fundus autofluorescent, and adaptive optics fundus images. The cone photoreceptors in the adaptive optics images of the two patients with retinitis pigmentosa and five healthy subjects were analyzed. An abnormal parafoveal ring of high-density fundus autofluorescence was observed in the macula in both patients. The border of the ring corresponded to the border of the external limiting membrane and the inner segment and outer segment line in the optical coherence tomographic images. Cone photoreceptors at the abnormal parafoveal ring were blurred and decreased in the adaptive optics images. The blurred area corresponded to the abnormal parafoveal ring in the fundus autofluorescence images. Cone densities were low at the blurred areas and at the nasal and temporal retina along a line from the fovea compared with those of healthy controls. The results for cone spacing and Voronoi domains in the macula corresponded with those for the cone densities. Cone densities were heavily decreased in the macula, especially at the parafoveal ring on high-density fundus autofluorescence in both patients with retinitis pigmentosa. Adaptive optics images enabled us to observe in vivo changes in the cone photoreceptors of patients with retinitis pigmentosa, which corresponded to changes in the optical coherence tomographic and fundus autofluorescence images.

  4. Coaxial fundus camera for opthalmology

    Science.gov (United States)

    de Matos, Luciana; Castro, Guilherme; Castro Neto, Jarbas C.

    2015-09-01

    A Fundus Camera for ophthalmology is a high definition device which needs to meet low light illumination of the human retina, high resolution in the retina and reflection free image1. Those constraints make its optical design very sophisticated, but the most difficult to comply with is the reflection free illumination and the final alignment due to the high number of non coaxial optical components in the system. Reflection of the illumination, both in the objective and at the cornea, mask image quality, and a poor alignment make the sophisticated optical design useless. In this work we developed a totally axial optical system for a non-midriatic Fundus Camera. The illumination is performed by a LED ring, coaxial with the optical system and composed of IR of visible LEDs. The illumination ring is projected by the objective lens in the cornea. The Objective, LED illuminator, CCD lens are coaxial making the final alignment easily to perform. The CCD + capture lens module is a CCTV camera with autofocus and Zoom built in, added to a 175 mm focal length doublet corrected for infinity, making the system easily operated and very compact.

  5. Feasibility and quality of nonmydriatic fundus photography in children

    Science.gov (United States)

    Toffoli, Daniela; Bruce, Beau B.; Lamirel, Cédric; Henderson, Amanda D.; Newman, Nancy J.; Biousse, Valérie

    2011-01-01

    Purpose Ocular funduscopic examination is difficult in young children and is rarely attempted by nonophthalmologists. Our objective was to determine the feasibility of reliably obtaining high-quality nonmydriatic fundus photographs in children. Methods Nonmydriatic fundus photographs were obtained in both eyes of children seen in a pediatric ophthalmology clinic. Ease of fundus photography was recorded on a 10-point Likert scale (10 = very easy). Quality was graded from 1 to 5 (1, inadequate for any diagnostic purpose; 2, unable to exclude all emergent findings; 3, only able to exclude emergent findings; 4, not ideal, but still able to exclude subtle findings; and 5, ideal quality). The primary outcome measure was image quality by age. Results A total of 878 photographs of 212 children (median age, 6 years; range,1-18 years) were included. Photographs of at least one eye were obtained in 190 children (89.6%) and in both eyes in 181 (85.3%). Median rating for ease of photography was 7. Photographs of some clinical value (grade ≥2) were obtained in 33% of children 3 years. High-quality photographs (grade 4 or 5) were obtained in both eyes in 7% of children <3 years, 57% of children ≥3 to <7 years, 85% of children ≥7 to <9 years, and 65% of children ≥9 years. The youngest patient with high-quality photographs in both eyes was 22 months. Conclusions Nonmydriatic fundus photographs of adequate quality can be obtained in children over age 3 and in some children as young as 22 months. PMID:22153402

  6. Quantitative Fundus Autofluorescence in Recessive Stargardt Disease

    OpenAIRE

    Burke, Tomas R.; Duncker, Tobias; Woods, Russell L.; Greenberg, Jonathan P.; Zernant, Jana; Tsang, Stephen H.; Smith, R. Theodore; Allikmets, Rando; Sparrow, Janet R.; Delori, François C.

    2014-01-01

    Quantitative fundus autofluorescence (qAF) is significantly increased in Stargardt disease, consistent with previous reports of increased RPE lipofuscin. QAF will help to establish genotype-phenotype correlations and may serve as an outcome measure in clinical trials.

  7. Analysis of visual pigment by fundus autofluorescence.

    NARCIS (Netherlands)

    Theelen, T.; Berendschot, T.T.; Boon, C.J.F.; Hoyng, C.B.; Klevering, B.J.

    2008-01-01

    This study investigated changes of short-wavelength fundus autofluorescence (SW-AF) by retinal bleaching effects. All measurements were performed with the Heidelberg Retina Angiograph 2 (HRA 2). Initially, experimental imaging was done on a healthy eye after dark adaptation. Photopigment was

  8. Fundus autofluorescence findings in a mouse model of retinal detachment.

    Science.gov (United States)

    Secondi, Roberta; Kong, Jian; Blonska, Anna M; Staurenghi, Giovanni; Sparrow, Janet R

    2012-08-07

    Fundus autofluorescence (fundus AF) changes were monitored in a mouse model of retinal detachment (RD). RD was induced by transscleral injection of hyaluronic acid (Healon) or sterile balanced salt solution (BSS) into the subretinal space of 4-5-day-old albino Abca4 null mutant and Abca4 wild-type mice. Images acquired by confocal scanning laser ophthalmoscopy (Spectralis HRA) were correlated with spectral domain optical coherence tomography (SD-OCT), infrared reflectance (IR), fluorescence spectroscopy, and histologic analysis. Results. In the area of detached retina, multiple hyperreflective spots in IR images corresponded to punctate areas of intense autofluorescence visible in fundus AF mode. The puncta exhibited changes in fluorescence intensity with time. SD-OCT disclosed undulations of the neural retina and hyperreflectivity of the photoreceptor layer that likely corresponded to histologically visible photoreceptor cell rosettes. Fluorescence emission spectra generated using flat-mounted retina, and 488 and 561 nm excitation, were similar to that of RPE lipofuscin. With increased excitation wavelength, the emission maximum shifted towards longer wavelengths, a characteristic typical of fundus autofluorescence. In detached retinas, hyper-autofluorescent spots appeared to originate from photoreceptor outer segments that were arranged within retinal folds and rosettes. Consistent with this interpretation is the finding that the autofluorescence was spectroscopically similar to the bisretinoids that constitute RPE lipofuscin. Under the conditions of a RD, abnormal autofluorescence may arise from excessive production of bisretinoid by impaired photoreceptor cells.

  9. Comparison of optical coherence tomography and fundus photography for measuring the optic disc size.

    Science.gov (United States)

    Neubauer, Aljoscha S; Krieglstein, Tina R; Chryssafis, Christos; Thiel, Martin; Kampik, Anselm

    2006-01-01

    To assess the agreement and repeatability of optic nerve head (ONH) size measurements by optical coherence tomography (OCT) as compared to conventional planimetry of fundus photographs in normal eyes. For comparison with planimetry the absolute size of the ONH of 25 eyes from 25 normal subjects were measured by both OCT and digital fundus photography (Zeiss FF camera 450). Repeatability of automated Stratus OCT measurements were investigated by repeatedly measuring the optic disc in five normal subjects. Mean disc size was 1763 +/- 186 vertically and 1632 +/- 160 microm horizontally on planimetry. On OCT, values of 1772 +/- 317 microm vertically (p = 0.82) and a significantly smaller horizontal diameter of 1492 +/- 302 microm (p = 0.04) were obtained. The 95% limits of agreement were (-546 microm; +527 microm) for vertical and (-502 microm; +782 microm) for horizontal planimetric compared to OCT measurements. In some cases large discrepancies existed. Repeatability of automatic measurements of the optic disc by OCT was moderately good with intra-class correlation coefficients (ICC) of 0.78 horizontally and 0.83 vertically. The coefficient of repeatability indicating instrument precision was 80 microm for horizontal and 168 microm for vertical measurements. OCT can be used to determine optic disc margins in moderate agreement with planimetry in normal subjects. However, in some cases significant disagreement with photographic assessment may occur making manual inspection advisable. Automatic disc detection by OCT is moderately repeatable.

  10. Adaptive optics scanning laser ophthalmoscopy in fundus imaging, a review and update

    OpenAIRE

    Zhang, Bing; Li, Ni; Kang, Jie; He, Yi; Chen, Xiao-Ming

    2017-01-01

    Adaptive optics scanning laser ophthalmoscopy (AO-SLO) has been a promising technique in funds imaging with growing popularity. This review firstly gives a brief history of adaptive optics (AO) and AO-SLO. Then it compares AO-SLO with conventional imaging methods (fundus fluorescein angiography, fundus autofluorescence, indocyanine green angiography and optical coherence tomography) and other AO techniques (adaptive optics flood-illumination ophthalmoscopy and adaptive optics optical coherenc...

  11. Ocular Fundus Photography as a Tool to Study Stroke and Dementia.

    Science.gov (United States)

    Cheung, Carol Y; Chen, Christopher; Wong, Tien Y

    2015-10-01

    Although cerebral small vessel disease has been linked to stroke and dementia, due to limitations of current neuroimaging technology, direct in vivo visualization of changes in the cerebral small vessels (e.g., cerebral arteriolar narrowing, tortuous microvessels, blood-brain barrier damage, capillary microaneurysms) is difficult to achieve. As the retina and the brain share similar embryological origin, anatomical features, and physiologic properties with the cerebral small vessels, the retinal vessels offer a unique and easily accessible "window" to study the correlates and consequences of cerebral small vessel diseases in vivo. The retinal microvasculature can be visualized, quantified and monitored noninvasively using ocular fundus photography. Recent clinic- and population-based studies have demonstrated a close link between retinal vascular changes seen on fundus photography and stroke and dementia, suggesting that ocular fundus photography may provide insights to the contribution of microvascular disease to stroke and dementia. In this review, we summarize current knowledge on retinal vascular changes, such as retinopathy and changes in retinal vascular measures with stroke and dementia as well as subclinical makers of cerebral small vessel disease, and discuss the possible clinical implications of these findings in neurology. Studying pathologic changes of retinal blood vessels may be useful for understanding the etiology of various cerebrovascular conditions; hence, ocular fundus photography can be potentially translated into clinical practice. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. PATTERNS OF FUNDUS AUTOFLUORESCENCE DEFECTS IN NEOVASCULAR AGE-RELATED MACULAR DEGENERATION SUBTYPES.

    Science.gov (United States)

    Ozkok, Ahmet; Sigford, Douglas K; Tezel, Tongalp H

    2016-11-01

    To test define characteristic fundus autofluorescence patterns of different exudative age-related macular degeneration subtypes. Cross-sectional study. Fifty-two patients with choroidal neovascularization because of three different neovascular age-related macular degeneration subtypes were included in the study. Macular and peripheral fundus autofluorescence patterns of study subjects were compared in a masked fashion. Fundus autofluorescence patterns of all three neovascular age-related macular degeneration subtypes revealed similar patterns. However, peripapillary hypo-autofluorescence was more common among patients with polypoidal choroidal vasculopathy (88.2%) compared with patients with retinal angiomatous proliferation (12.5%) and patients without retinal angiomatous proliferation and polypoidal choroidal vasculopathy (21.1%) (P autofluorescence defects in neovascular age-related macular degeneration maybe suggestive of polypoidal choroidal vasculopathy as a variant of neovascular age-related macular degeneration.

  13. Case Report of Bullous Pemphigoid following Fundus Fluorescein Angiography

    Directory of Open Access Journals (Sweden)

    Goktug Demirci

    2010-05-01

    Full Text Available Purpose: To report a first case of bullous pemphigoid (BP following intravenous fluorescein for fundus angiography. Clinical Features: A 70-year-old male patient was admitted to the intensive care unit with BP and sepsis. He reported a history of fundus fluorescein angiography with a pre-diagnosis of senile macular degeneration 2 months prior to presentation. At that time, fluorescein extravasated at the antecubital region. Following the procedure, pruritus and erythema began at the wrists bilaterally, and quickly spread to the entire body. The patient also reported a history of allergy to human albumin solution (Plamasteril®; Abbott 15 years before, during bypass surgery. On dermatologic examination, erythematous patches were present on the scalp, chest and anogenital region. Vesicles and bullous lesions were present on upper and lower extremities. On day 2 of hospitalization, tense bullae appeared on the upper and lower extremities. The patient was treated with oral methylprednisolone 48 mg (Prednol®; Mustafa Nevzat, topical clobetasol dipropionate 0.05% cream (Dermovate®; Glaxo SmithKline, and topical 4% urea lotion (Excipial Lipo®; Orva for presumptive bullous pemphigoid. Skin punch biopsy provided tissue for histopathology, direct immunofluorescence examination, and salt extraction, which were all consistent with BP. After 1 month, the patient was transferred to the intensive care unit with sepsis secondary to urinary tract infection; he died 2 weeks later from sepsis and cardiac failure. Conclusions: To our knowledge, this is the first reported case of BP following fundus fluorescein angiography in a patient with known human albumin solution allergy. Consideration should be made to avoid fluorescein angiography, change administration route, or premedicate with antihistamines in patients with known human albumin solution allergy. The association between fundus fluorescein angiography and BP should be further investigated.

  14. Rapid grading of fundus photographs for diabetic retinopathy using crowdsourcing.

    Science.gov (United States)

    Brady, Christopher J; Villanti, Andrea C; Pearson, Jennifer L; Kirchner, Thomas R; Gupta, Omesh P; Shah, Chirag P

    2014-10-30

    ) from 26.3% (5/19 images). Throughout all trials, 100% sensitivity for normal versus abnormal was maintained. With minimal training, the Amazon Mechanical Turk workforce can rapidly and correctly categorize fundus photos of diabetic patients as normal or abnormal, though further refinement of the methodology is needed to improve Turker ratings of the degree of retinopathy. Images were interpreted for a total cost of US $1.10 per eye. Crowdsourcing may offer a novel and inexpensive means to reduce the skilled grader burden and increase screening for diabetic retinopathy.

  15. Analysis of phakic before intraocular lens implantation for fundus examination

    Directory of Open Access Journals (Sweden)

    Juan Chen

    2014-10-01

    Full Text Available AIM:To investigate the findings of the eyes which were examined preoperatively by three mirror contact lens before the implantation of implantable collamer lens(ICL. To analysis the retinal pathological changes and to explore the clinical analysis of early diagnosis and treatment in retinopathy on fundus examination before operation. METHODS:The retrospective case series study included 127 eyes of 64 patients who underwent phakic intraocular lens implantation were received the fundus examination by three mirror from April 2011 to April 2012 in our hospital. The age, refractive diopter, the findings of Goldmann three mirror examination and the condition of retinal photocoagulation were analysed and concluded.RESULTS: A total of 34 eyes(26.8%out of all 127 eyes(64 caseswere found to have peripheral retinal pathological changes. Eight eyes(6.3%with retinal holes, 15 eyes(11.8%with retinal lattice degeneration, 5 eyes(3.9%with retina cream degeneration, 3 eyes(2.4%with retinal paving stone degeneration,2 eyes with vitreoretinal adhesion and traction,1 eye(0.8%with retinal hemorrhage. Twenty-five cases were given retinal photocoagulation and then received the ICL implantation after 3mo. The follow-up time was 1a. No retinal detachment happened.CONCLUSION:Phakic before intraocular lens implantation for fundus examination by three mirror is contributed to find the peripheral retinal pathological changes and abnormity. And make the appropriate treatment before operation for improving the security of operation, it can also give help to the postoperative follow-up of the fundus of these patients.

  16. Retinal fundus imaging with a plenoptic sensor

    Science.gov (United States)

    Thurin, Brice; Bloch, Edward; Nousias, Sotiris; Ourselin, Sebastien; Keane, Pearse; Bergeles, Christos

    2018-02-01

    Vitreoretinal surgery is moving towards 3D visualization of the surgical field. This require acquisition system capable of recording such 3D information. We propose a proof of concept imaging system based on a light-field camera where an array of micro-lenses is placed in front of a conventional sensor. With a single snapshot, a stack of images focused at different depth are produced on the fly, which provides enhanced depth perception for the surgeon. Difficulty in depth localization of features and frequent focus-change during surgery are making current vitreoretinal heads-up surgical imaging systems cumbersome to use. To improve the depth perception and eliminate the need to manually refocus on the instruments during the surgery, we designed and implemented a proof-of-concept ophthalmoscope equipped with a commercial light-field camera. The sensor of our camera is composed of an array of micro-lenses which are projecting an array of overlapped micro-images. We show that with a single light-field snapshot we can digitally refocus between the retina and a tool located in front of the retina or display an extended depth-of-field image where everything is in focus. The design and system performances of the plenoptic fundus camera are detailed. We will conclude by showing in vivo data recorded with our device.

  17. Fundus autofluorescence applications in retinal imaging

    Science.gov (United States)

    Gabai, Andrea; Veritti, Daniele; Lanzetta, Paolo

    2015-01-01

    Fundus autofluorescence (FAF) is a relatively new imaging technique that can be used to study retinal diseases. It provides information on retinal metabolism and health. Several different pathologies can be detected. Peculiar AF alterations can help the clinician to monitor disease progression and to better understand its pathogenesis. In the present article, we review FAF principles and clinical applications. PMID:26139802

  18. Fundus autofluorescence applications in retinal imaging

    Directory of Open Access Journals (Sweden)

    Andrea Gabai

    2015-01-01

    Full Text Available Fundus autofluorescence (FAF is a relatively new imaging technique that can be used to study retinal diseases. It provides information on retinal metabolism and health. Several different pathologies can be detected. Peculiar AF alterations can help the clinician to monitor disease progression and to better understand its pathogenesis. In the present article, we review FAF principles and clinical applications.

  19. Hearing preservation in retrosigmoid approach of small vestibular schwannomas: prognostic value of the degree of internal auditory canal filling.

    Science.gov (United States)

    Tringali, Stéphane; Ferber-Viart, Chantal; Fuchsmann, Carine; Buiret, Guillaume; Zaouche, Sandra; Dubreuil, Christian

    2010-12-01

    To assess the contribution of preoperative radiologic appearance of vestibular schwannoma (VS) on the magnetic resonance imaging in constructive interference in steady-state sequences and demonstrate if the degree of the internal auditory canal (IAC) filling is correlated with hearing and facial preservation. A group of 278 patients who underwent VS surgery in a tertiary referral center. Retrosigmoid approach surgery. Patients were classified in 4 groups according to the percentage of IAC filling on the preoperative magnetic resonance imaging as Group IAC 1(IAC empty or filled filled from 25% to 50% with free fundus), Group IAC 3 (IAC filled from 50% to 75% with free fundus), and Group IAC 4 (complete filling of the IAC without fundus obliteration). A good correlation was observed between the IAC classification and the rate of hearing and facial preservation. The global rate of postoperative facial palsy was 10.4%. The global rate of hearing preservation in 213 patients with preoperative hearing class A and B was 40.8%. Regression analysis showed that the degree of lateral extension of the VS in the IAC was a strong predictor of hearing preservation ( p facial outcomes in selected patients with possible hearing preservation. In case of patient with small tumor and IAC empty or filled less than 75% and with free fundus, surgery is the treatment of choice for patients with serviceable hearing and the desire to retain it.

  20. A thresholding based technique to extract retinal blood vessels from fundus images

    Directory of Open Access Journals (Sweden)

    Jyotiprava Dash

    2017-12-01

    Full Text Available Retinal imaging has become the significant tool among all the medical imaging technology, due to its capability to extract many data which is linked to various eye diseases. So, the accurate extraction of blood vessel is necessary that helps the eye care specialists and ophthalmologist to identify the diseases at the early stages. In this paper, we have proposed a computerized technique for extraction of blood vessels from fundus images. The process is conducted in three phases: (i pre-processing where the image is enhanced using contrast limited adaptive histogram equalization and median filter, (ii segmentation using mean-C thresholding to extract retinal blood vessels, (iii post-processing where morphological cleaning operation is used to remove isolated pixels. The performance of the proposed method is tested on and experimental results show that our method achieve an accuracies of 0.955 and 0.954 on Digital retinal images for vessel extraction (DRIVE and Child heart and health study in England (CHASE_DB1 databases respectively.

  1. Ophthalmoscopy versus non-mydriatic fundus photography in the ...

    African Journals Online (AJOL)

    1990-09-01

    Sep 1, 1990 ... non-mydriatic fundus camera in the detection of diabetic retinopathy .... the external and the internal fixation lamps of the non- mydriatic ... .Rosen ES, Raines M, Hancock R. Use of non-mydriatic cameras to screen diabetic ...

  2. A review of fundus autofluorescence imaging

    OpenAIRE

    D. J. Booysen

    2013-01-01

    Autofluorscence photography of the retina provides important diagnostic information about diseases that affect the outer retina; more specifically the retinal pigment epithelium and photoreceptors. Fundus autofluorescence can alsobe used to evaluate macular pigment density and other diseases of the retina and choroid. It is a non-invasive clinical tool which has the potential to revolutionise clinical retina practice. (S Afr Optom 2013 72(1) 46-53)

  3. Computer-aided diagnosis based on enhancement of degraded fundus photographs.

    Science.gov (United States)

    Jin, Kai; Zhou, Mei; Wang, Shaoze; Lou, Lixia; Xu, Yufeng; Ye, Juan; Qian, Dahong

    2018-05-01

    Retinal imaging is an important and effective tool for detecting retinal diseases. However, degraded images caused by the aberrations of the eye can disguise lesions, so that a diseased eye can be mistakenly diagnosed as normal. In this work, we propose a new image enhancement method to improve the quality of degraded images. A new method is used to enhance degraded-quality fundus images. In this method, the image is converted from the input RGB colour space to LAB colour space and then each normalized component is enhanced using contrast-limited adaptive histogram equalization. Human visual system (HVS)-based fundus image quality assessment, combined with diagnosis by experts, is used to evaluate the enhancement. The study included 191 degraded-quality fundus photographs of 143 subjects with optic media opacity. Objective quality assessment of image enhancement (range: 0-1) indicated that our method improved colour retinal image quality from an average of 0.0773 (variance 0.0801) to an average of 0.3973 (variance 0.0756). Following enhancement, area under curves (AUC) were 0.996 for the glaucoma classifier, 0.989 for the diabetic retinopathy (DR) classifier, 0.975 for the age-related macular degeneration (AMD) classifier and 0.979 for the other retinal diseases classifier. The relatively simple method for enhancing degraded-quality fundus images achieves superior image enhancement, as demonstrated in a qualitative HVS-based image quality assessment. This retinal image enhancement may, therefore, be employed to assist ophthalmologists in more efficient screening of retinal diseases and the development of computer-aided diagnosis. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. Automated Detection of Glaucoma From Topographic Features of the Optic Nerve Head in Color Fundus Photographs.

    Science.gov (United States)

    Chakrabarty, Lipi; Joshi, Gopal Datt; Chakravarty, Arunava; Raman, Ganesh V; Krishnadas, S R; Sivaswamy, Jayanthi

    2016-07-01

    To describe and evaluate the performance of an automated CAD system for detection of glaucoma from color fundus photographs. Color fundus photographs of 2252 eyes from 1126 subjects were collected from 2 centers: Aravind Eye Hospital, Madurai and Coimbatore, India. The images of 1926 eyes (963 subjects) were used to train an automated image analysis-based system, which was developed to provide a decision on a given fundus image. A total of 163 subjects were clinically examined by 2 ophthalmologists independently and their diagnostic decisions were recorded. The consensus decision was defined to be the clinical reference (gold standard). Fundus images of eyes with disagreement in diagnosis were excluded from the study. The fundus images of the remaining 314 eyes (157 subjects) were presented to 4 graders and their diagnostic decisions on the same were collected. The performance of the system was evaluated on the 314 images, using the reference standard. The sensitivity and specificity of the system and 4 independent graders were determined against the clinical reference standard. The system achieved an area under receiver operating characteristic curve of 0.792 with a sensitivity of 0.716 and specificity of 0.717 at a selected threshold for the detection of glaucoma. The agreement with the clinical reference standard as determined by Cohen κ is 0.45 for the proposed system. This is comparable to that of the image-based decisions of 4 ophthalmologists. An automated system was presented for glaucoma detection from color fundus photographs. The overall evaluation results indicated that the presented system was comparable in performance to glaucoma classification by a manual grader solely based on fundus image examination.

  5. Telemedicine for diabetic retinopathy screening using an ultra-widefield fundus camera

    Directory of Open Access Journals (Sweden)

    Hussain N

    2017-08-01

    Full Text Available Nazimul Hussain,1 Maryam Edraki,2 Rima Tahhan,2 Nishanth Sanalkumar,2 Sami Kenz,2 Nagwa Khalil Akasha,2 Brian Mtemererwa,2 Nahed Mohammed2 1Department of Ophthalmology, Al Zahra Hospital, Sharjah, United Arab Emirates; 2Department of Endocrinology, Al Zahra Hospital, Sharjah, United Arab Emirates Objective: Telemedicine reporting of diabetic retinopathy (DR screening using ultra-widefield (UWF fundus camera. Materials and methods: Cross-sectional study of diabetic patients who visited the endocrinology department of a private multi-specialty hospital in United Arab Emirates between April 2015 and January 2017 who underwent UWF fundus imaging. Fundus pictures are then accessed at the Retina Clinic in the Department of Ophthalmology. Primary outcome measure was incidence of any form of DR detected. The secondary outcome measure was failure to take good image and inability to grade. Results: A total of 1,024 diabetic individuals were screened for DR from April 2015 to January 2017 in the department of Endocrinology. Rate of DR was 9.27%; 165 eyes of 95 individuals were diagnosed to have some form of DR. Mild non-proliferative DR (NPDR was seen in 114 of 165 eyes (69.09%, moderate NPDR in 32 eyes (19.39%, severe NPDR in six eyes (3.64%, and proliferative DR (PDR in 13 eyes (7.88%. The secondary outcome measure of poor image acquisition was seen in one individual who had an image acquired in one eye that could not be graded due to bad picture quality. Conclusions: The present study has shown the effectiveness of DR screening using UWF fundus camera. It has shown the effectiveness of trained nursing personnel taking fundus images. This model can be replicated in any private multi-specialty hospital and reduce the burden of DR screening in the retina clinic and enhance early detection of treatable DR. Keywords: telemedicine, ultra-widefield camera, diabetic retinopathy screening

  6. [Cinematography of ocular fundus with a jointed optical system and tv or cine-camera (author's transl)].

    Science.gov (United States)

    Kampik, A; Rapp, J

    1979-02-01

    A method of Cinematography of the ocular fundus is introduced which--by connecting a camera with an indirect ophthalmoscop--allows to record the monocular picture of the fundus as produced by the ophthalmic lens.

  7. DrishtiCare: a telescreening platform for diabetic retinopathy powered with fundus image analysis.

    Science.gov (United States)

    Joshi, Gopal Datt; Sivaswamy, Jayanthi

    2011-01-01

    Diabetic retinopathy is the leading cause of blindness in urban populations. Early diagnosis through regular screening and timely treatment has been shown to prevent visual loss and blindness. It is very difficult to cater to this vast set of diabetes patients, primarily because of high costs in reaching out to patients and a scarcity of skilled personnel. Telescreening offers a cost-effective solution to reach out to patients but is still inadequate due to an insufficient number of experts who serve the diabetes population. Developments toward fundus image analysis have shown promise in addressing the scarcity of skilled personnel for large-scale screening. This article aims at addressing the underlying issues in traditional telescreening to develop a solution that leverages the developments carried out in fundus image analysis. We propose a novel Web-based telescreening solution (called DrishtiCare) integrating various value-added fundus image analysis components. A Web-based platform on the software as a service (SaaS) delivery model is chosen to make the service cost-effective, easy to use, and scalable. A server-based prescreening system is employed to scrutinize the fundus images of patients and to refer them to the experts. An automatic quality assessment module ensures transfer of fundus images that meet grading standards. An easy-to-use interface, enabled with new visualization features, is designed for case examination by experts. Three local primary eye hospitals have participated and used DrishtiCare's telescreening service. A preliminary evaluation of the proposed platform is performed on a set of 119 patients, of which 23% are identified with the sight-threatening retinopathy. Currently, evaluation at a larger scale is under process, and a total of 450 patients have been enrolled. The proposed approach provides an innovative way of integrating automated fundus image analysis in the telescreening framework to address well-known challenges in large

  8. A review of fundus autofluorescence imaging

    Directory of Open Access Journals (Sweden)

    D. J. Booysen

    2013-12-01

    Full Text Available Autofluorscence photography of the retina provides important diagnostic information about diseases that affect the outer retina; more specifically the retinal pigment epithelium and photoreceptors. Fundus autofluorescence can alsobe used to evaluate macular pigment density and other diseases of the retina and choroid. It is a non-invasive clinical tool which has the potential to revolutionise clinical retina practice. (S Afr Optom 2013 72(1 46-53

  9. Fractal and digital image processing to determine the degree of dispersion of carbon nanotubes

    International Nuclear Information System (INIS)

    Liang, Xiao-ning; Li, Wei

    2016-01-01

    The degree of dispersion is an important parameter to quantitatively study properties of carbon nanotube composites. Among the many methods for studying dispersion, scanning electron microscopy, transmission electron microscopy, and atomic force microscopy are the most commonly used, intuitive, and convincing methods. However, they have the disadvantage of not being quantitative. To overcome this disadvantage, the fractal theory and digital image processing method can be used to provide a quantitative analysis of the morphology and properties of carbon nanotube composites. In this paper, the dispersion degree of carbon nanotubes was investigated using two fractal methods, namely, the box-counting method and the differential box-counting method. On the basis of the results, we propose a new method for the quantitative characterization of the degree of dispersion of carbon nanotubes. This hierarchical grid method can be used as a supplementary method, and can be combined with the fractal calculation method. Thus, the accuracy and effectiveness of the quantitative characterization of the dispersion degree of carbon nanotubes can be improved. (The outer diameter of the carbon nanotubes is about 50 nm; the length of the carbon nanotubes is 10–20 μm.)

  10. Fractal and digital image processing to determine the degree of dispersion of carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Xiao-ning, E-mail: xnliang0506@163.com; Li, Wei, E-mail: 1099006@mail.dhu.edu.cn, E-mail: liwei@dhu.edu.cn, E-mail: waiwentougao@outlook.com [Donghua University, College of Textiles (China)

    2016-05-15

    The degree of dispersion is an important parameter to quantitatively study properties of carbon nanotube composites. Among the many methods for studying dispersion, scanning electron microscopy, transmission electron microscopy, and atomic force microscopy are the most commonly used, intuitive, and convincing methods. However, they have the disadvantage of not being quantitative. To overcome this disadvantage, the fractal theory and digital image processing method can be used to provide a quantitative analysis of the morphology and properties of carbon nanotube composites. In this paper, the dispersion degree of carbon nanotubes was investigated using two fractal methods, namely, the box-counting method and the differential box-counting method. On the basis of the results, we propose a new method for the quantitative characterization of the degree of dispersion of carbon nanotubes. This hierarchical grid method can be used as a supplementary method, and can be combined with the fractal calculation method. Thus, the accuracy and effectiveness of the quantitative characterization of the dispersion degree of carbon nanotubes can be improved. (The outer diameter of the carbon nanotubes is about 50 nm; the length of the carbon nanotubes is 10–20 μm.)

  11. Correlation between Spectral Optical Coherence Tomography and Fundus Autofluorescence at the margins of Geographic Atrophy

    Science.gov (United States)

    Brar, Manpreet; Kozak, Igor; Cheng, Lingyun; Bartsch, Dirk-Uwe G.; Yuson, Ritchie; Nigam, Nitin; Oster, Stephen F.; Mojana, Francesca; Freeman, William R.

    2009-01-01

    Purpose We studied the appearance of margins of Geographic atrophy in high- resolution optical coherence tomography (OCT) images and correlate those changes with fundus autofluorescence imaging. Design Retrospective observational case study. Methods Patients with geographic atrophy secondary to dry age related macular degeneration (ARMD) were assessed by means of Spectral Domain OCT (Spectralis HRA/OCT; Heidelberg Engineering, Heidelberg, Germany or OTI, Inc, Toronto, Canada) as well as Autofluoresence Imaging (HRA or Spectralis Heidelberg Engineering, Heidelberg, Germany): The outer retinal layer alterations were analyzed in the junctional zone between normal retina and atrophic retina, and correlated with corresponding fundus autofluorescence. Results 23 eyes of 16 patients aged between 62 years to 96 years were examined. There was a significant association between OCT findings and the fundus autofluorescence findings(r=0.67, pautofluorescence; Smooth margins on OCT correspond significantly to normal fundus autofluorescence. (Kappa-0.7348, pautofluorescence; secondary to increased lipofuscin may together serve as determinants of progression of geographic atrophy. PMID:19541290

  12. Automated detection and differentiation of drusen, exudates, and cotton-wool spots in digital color fundus photographs for diabetic retinopathy diagnosis.

    Science.gov (United States)

    Niemeijer, Meindert; van Ginneken, Bram; Russell, Stephen R; Suttorp-Schulten, Maria S A; Abràmoff, Michael D

    2007-05-01

    To describe and evaluate a machine learning-based, automated system to detect exudates and cotton-wool spots in digital color fundus photographs and differentiate them from drusen, for early diagnosis of diabetic retinopathy. Three hundred retinal images from one eye of 300 patients with diabetes were selected from a diabetic retinopathy telediagnosis database (nonmydriatic camera, two-field photography): 100 with previously diagnosed bright lesions and 200 without. A machine learning computer program was developed that can identify and differentiate among drusen, (hard) exudates, and cotton-wool spots. A human expert standard for the 300 images was obtained by consensus annotation by two retinal specialists. Sensitivities and specificities of the annotations on the 300 images by the automated system and a third retinal specialist were determined. The system achieved an area under the receiver operating characteristic (ROC) curve of 0.95 and sensitivity/specificity pairs of 0.95/0.88 for the detection of bright lesions of any type, and 0.95/0.86, 0.70/0.93, and 0.77/0.88 for the detection of exudates, cotton-wool spots, and drusen, respectively. The third retinal specialist achieved pairs of 0.95/0.74 for bright lesions and 0.90/0.98, 0.87/0.98, and 0.92/0.79 per lesion type. A machine learning-based, automated system capable of detecting exudates and cotton-wool spots and differentiating them from drusen in color images obtained in community based diabetic patients has been developed and approaches the performance level of retinal experts. If the machine learning can be improved with additional training data sets, it may be useful for detecting clinically important bright lesions, enhancing early diagnosis, and reducing visual loss in patients with diabetes.

  13. Fundus autofluorescence and optical coherence tomography of congenital grouped albinotic spots.

    Science.gov (United States)

    Kim, David Y; Hwang, John C; Moore, Anthony T; Bird, Alan C; Tsang, Stephen H

    2010-09-01

    The purpose of this study was to describe the findings of fundus autofluores-cence (FAF) and optical coherence tomography in a series of patients with congenital grouped albinotic spots. Three eyes of three patients with congenital grouped albinotic spots were evaluated with FAF and optical coherence tomography imaging to evaluate the nature of the albinotic spots. In all three eyes with congenital grouped albinotic spots, FAF imaging showed autofluorescent spots corresponding to the albinotic spots seen on stereo biomicroscopy. One eye also had additional spots detected on FAF imaging that were not visible on stereo biomicroscopy or color fundus photographs. Fundus autofluorescence imaging of the spots showed decreased general autofluorescence and decreased peripheral autofluorescence surrounding central areas of retained or increased autofluorescence. Optical coherence tomography showed a disruption in signal from the hyperreflective layer corresponding to the inner and outer segment junction and increased signal backscattering from the choroid in the area of the spots. Fluorescein angiography showed early and stable hyperfluorescence of the spots without leakage. In this case series, FAF showed decreased autofluorescence of the spots consistent with focal retinal pigment epithelium atrophy or abnormal material blocking normal autofluorescence and areas of increased autofluorescence suggesting retinal pigment epithelium dysfunction. The findings of optical coherence tomography and fluorescein angiography suggest photoreceptor and retinal pigment epithelium layer abnormalities. Fundus autofluorescence and optical coherence tomography are useful noninvasive diagnostic adjuncts that can aid in the diagnosis of congenital grouped albinotic spots, help determine extent of disease, and contribute to our understanding of its pathophysiology.

  14. Centrifugal expansion of fundus autofluorescence patterns in Stargardt disease over time.

    Science.gov (United States)

    Cukras, Catherine A; Wong, Wai T; Caruso, Rafael; Cunningham, Denise; Zein, Wadih; Sieving, Paul A

    2012-02-01

    To study the longitudinal changes in autofluorescence in Stargardt disease to reveal aspects of disease progression not previously evident. Changes in autofluorescence reflect changing fluorophore compositions of lipofuscin and melanin in retinal pigment epithelial cells, which has been hypothesized to contribute to Stargardt disease pathogenesis. We examined the temporospatial patterns of fundus autofluorescence with excitation at both 488 nm (standard fundus autofluorescence) and 795 nm (near-infrared autofluorescence) in a longitudinal case series involving 8 eyes of 4 patients (range of follow-up, 11-57 months; mean, 39 months). Image processing was performed to analyze spatial and temporal cross-modality associations. Longitudinal fundus autofluorescence imaging of fleck lesions revealed hyperautofluorescent lesions that extended in a centrifugal direction from the fovea with time. Patterns of spread were nonrandom and followed a radial path that left behind a trail of diminishing autofluorescence. Longitudinal near-infrared autofluorescence imaging also demonstrated centrifugal lesion spread but with fewer hyperautofluorescent lesions, suggestive of more transient hyperautofluorescence and more rapid decay at longer wavelengths. Fundus autofluorescence and near-infrared autofluorescence abnormalities were spatially correlated with each other, and together they reflect systematic progressions in fleck distribution and fluorophore composition occurring during the natural history of the disease. Stargardt disease fleck lesions do not evolve randomly in location but instead follow consistent patterns of radial expansion and a systematic decay of autofluorescence that reflect changing lipofuscin and melanin compositions in retinal pigment epithelial cells. These progressive foveal-to-peripheral changes are helpful in elucidating molecular and cellular mechanisms underlying Stargardt disease and may constitute potential outcome measures in clinical trials.

  15. Opinion and Special Articles: Amateur fundus photography with various new devices: Our experience as neurology residents.

    Science.gov (United States)

    Zafar, Saman; Cardenas, Ylec Mariana; Leishangthem, Lakshmi; Yaddanapudi, Sridhara

    2018-05-08

    Times are changing in the way we secure and share patient fundus photographs to enhance our diagnostic skills in neurology. At the recent American Academy of Neurology meeting, the use of a fundus camera and smartphones to secure good-quality fundus photographs of patients presenting with headache to the emergency department (ED) was presented. We were enthusiastic to replicate the success of the Fundus Photography vs Ophthalmoscopy Trial Outcomes in the Emergency Department (FOTO-ED) study in our neurology department, but encountered problems in terms of cost, setup, feasibility, and portability of the device. As neurology residents, we came up with 3 easier options. We present these 3 options as our personal experience, and hope to reignite enthusiasm among neurology trainees to find their own means of performing ophthalmoscopy routinely in the hospital, as it appears that the Internet market is now thriving with many other devices to make this examination easier and more rewarding. Of the options explored above, the Handheld Fundus Camera was a clear favorite among the residents, and we have placed one in our call room for routine use. It travels to the clinic, floor, intensive care unit, and ED when needed. It has enhanced the way we approach the fundus examination and been a fun skill to acquire. We look forward to further advances that will make it possible to carry such a device in a physician's pocket. © 2018 American Academy of Neurology.

  16. Mechanism of resveratrol-induced relaxation of the guinea pig fundus.

    Science.gov (United States)

    Tsai, Ching-Chung; Tey, Shu-Leei; Lee, Ming-Che; Liu, Ching-Wen; Su, Yu-Tsun; Huang, Shih-Che

    2018-04-01

    Resveratrol is a polyphenolic compound that can be isolated from plants and also is a constituent of red wine. Resveratrol induces relaxation of vascular smooth muscle and may prevent cardiovascular diseases. Impaired gastric accommodation plays an important role in functional dyspepsia and fundic relaxation and is a therapeutic target of functional dyspepsia. Although drugs for fundic relaxation have been developed, these types of drugs are still rare. The purpose of this study was to investigate the relaxant effects of resveratrol in the guinea pig fundus. We studied the relaxant effects of resveratrol in the guinea pig fundus. In addition, we investigated the mechanism of resveratrol-induced relaxation on the guinea pig fundus by using tetraethylammonium (a non-selective potassium channel blocker), apamine (a selective inhibitor of the small conductance calcium-activated potassium channel), iberiotoxin (an inhibitor of large conductance calcium-activated potassium channels), glibenclamide (an ATP-sensitive potassium channel blocker), KT 5720 (a cAMP-dependent protein kinase A inhibitor), KT 5823 (a cGMP-dependent protein kinase G inhibitor), NG-nitro-L-arginine (a competitive inhibitor of nitric oxide synthase), tetrodotoxin (a selective neuronal Na + channel blocker), ω-conotoxin GVIA (a selective neuronal Ca 2+ channel blocker) and G-15 (a G-protein coupled estrogen receptor antagonist). The results of this study showed that resveratrol has potent and dose-dependent relaxant effects on the guinea pig fundic muscle. In addition, the results showed that resveratrol-induced relaxation of the guinea pig fundus occurs through nitric oxide and ATP-sensitive potassium channels. This study provides the first evidence concerning the relaxant effects of resveratrol in the guinea pig fundic muscle strips. Furthermore, resveratrol may be a potential drug to relieve gastrointestinal dyspepsia. Copyright © 2018 Elsevier GmbH. All rights reserved.

  17. Fundus autofluorescence and optical coherence tomography findings in thiamine responsive megaloblastic anemia.

    Science.gov (United States)

    Ach, Thomas; Kardorff, Rüdiger; Rohrschneider, Klaus

    2015-01-01

    To report ophthalmologic fundus autofluorescence and spectral domain optical coherence tomography findings in a patient with thiamine responsive megaloblastic anemia (TRMA). A 13-year-old girl with genetically proven TRMA was ophthalmologically (visual acuity, funduscopy, perimetry, electroretinogram) followed up over >5 years. Fundus imaging also included autofluorescence and spectral domain optical coherence tomography. During a 5-year follow-up, visual acuity and visual field decreased, despite a special TRMA diet. Funduscopy revealed bull's eye appearance, whereas fundus autofluorescence showed central and peripheral hyperfluorescence and perifoveal hypofluorescence. Spectral domain optical coherence tomography revealed affected inner segment ellipsoid band and irregularities in the retinal pigment epithelium and choroidea. Autofluorescence and spectral domain optical coherence tomography findings in a patient with TRMA show retinitis pigmentosa-like retina, retinal pigment epithelium, and choroid alterations. These findings might progress even under special TRMA diet, indispensable to life. Ophthalmologist should consider TRMA in patients with deafness and ophthalmologic disorders.

  18. Multi-frame super-resolution with quality self-assessment for retinal fundus videos.

    Science.gov (United States)

    Köhler, Thomas; Brost, Alexander; Mogalle, Katja; Zhang, Qianyi; Köhler, Christiane; Michelson, Georg; Hornegger, Joachim; Tornow, Ralf P

    2014-01-01

    This paper proposes a novel super-resolution framework to reconstruct high-resolution fundus images from multiple low-resolution video frames in retinal fundus imaging. Natural eye movements during an examination are used as a cue for super-resolution in a robust maximum a-posteriori scheme. In order to compensate heterogeneous illumination on the fundus, we integrate retrospective illumination correction for photometric registration to the underlying imaging model. Our method utilizes quality self-assessment to provide objective quality scores for reconstructed images as well as to select regularization parameters automatically. In our evaluation on real data acquired from six human subjects with a low-cost video camera, the proposed method achieved considerable enhancements of low-resolution frames and improved noise and sharpness characteristics by 74%. In terms of image analysis, we demonstrate the importance of our method for the improvement of automatic blood vessel segmentation as an example application, where the sensitivity was increased by 13% using super-resolution reconstruction.

  19. Supervised retinal vessel segmentation from color fundus images based on matched filtering and AdaBoost classifier.

    Directory of Open Access Journals (Sweden)

    Nogol Memari

    Full Text Available The structure and appearance of the blood vessel network in retinal fundus images is an essential part of diagnosing various problems associated with the eyes, such as diabetes and hypertension. In this paper, an automatic retinal vessel segmentation method utilizing matched filter techniques coupled with an AdaBoost classifier is proposed. The fundus image is enhanced using morphological operations, the contrast is increased using contrast limited adaptive histogram equalization (CLAHE method and the inhomogeneity is corrected using Retinex approach. Then, the blood vessels are enhanced using a combination of B-COSFIRE and Frangi matched filters. From this preprocessed image, different statistical features are computed on a pixel-wise basis and used in an AdaBoost classifier to extract the blood vessel network inside the image. Finally, the segmented images are postprocessed to remove the misclassified pixels and regions. The proposed method was validated using publicly accessible Digital Retinal Images for Vessel Extraction (DRIVE, Structured Analysis of the Retina (STARE and Child Heart and Health Study in England (CHASE_DB1 datasets commonly used for determining the accuracy of retinal vessel segmentation methods. The accuracy of the proposed segmentation method was comparable to other state of the art methods while being very close to the manual segmentation provided by the second human observer with an average accuracy of 0.972, 0.951 and 0.948 in DRIVE, STARE and CHASE_DB1 datasets, respectively.

  20. Fundus autofluorescence and optical coherence tomographic findings in acute zonal occult outer retinopathy.

    Science.gov (United States)

    Fujiwara, Takamitsu; Imamura, Yutaka; Giovinazzo, Vincent J; Spaide, Richard F

    2010-09-01

    The purpose of this study was to investigate the fundus autofluorescence and optical coherence tomography findings in eyes with acute zonal occult outer retinopathy (AZOOR). A retrospective observational case series of the fundus autofluorescence and spectral domain optical coherence tomography in a series of patients with AZOOR. There were 19 eyes of 11 patients (10 women), who had a mean age of 49.1 +/- 13.9 years. Fundus autofluorescence abnormalities were seen in 17 of the 19 eyes, were more common in the peripapillary area, and were smaller in extent than the optical coherence tomography abnormalities. Nine eyes showed progression of hypoautofluorescence area during the mean follow-up of 69.7 months. The mean thickness of the photoreceptor layer at fovea was 177 microm in eyes with AZOOR, which was significantly thinner than controls (193 microm, P = 0.049). Abnormal retinal laminations were found in 12 eyes and were located over areas of loss of the photoreceptors. The subfoveal choroidal thickness was 243 microm, which is normal. Fundus autofluorescence abnormalities in AZOOR showed distinct patterns of retinal pigment epithelial involvement, which may be progressive. Thinning of photoreceptor cell layer with loss of the outer segments and abnormal inner retinal lamination in the context of a normal choroid are commonly found in AZOOR.

  1. An evaluation of fundus photography and fundus autofluorescence in the diagnosis of cuticular drusen.

    Science.gov (United States)

    Høeg, Tracy B; Moldow, Birgitte; Klein, Ronald; La Cour, Morten; Klemp, Kristian; Erngaard, Ditte; Ellervik, Christina; Buch, Helena

    2016-03-01

    To examine non-mydriatic fundus photography (FP) and fundus autofluorescence (FAF) as alternative non-invasive imaging modalities to fluorescein angiography (FA) in the detection of cuticular drusen (CD). Among 2953 adults from the Danish Rural Eye Study (DRES) with gradable FP, three study groups were selected: (1) All those with suspected CD without age-related macular degeneration (AMD) on FP, (2) all those with suspected CD with AMD on FP and (3) a randomly selected group with early AMD. Groups 1, 2 and 3 underwent FA and FAF and group 4 underwent FAF only as part of DRES CD substudy. Main outcome measures included percentage of correct positive and correct negative diagnoses, Cohen's κ and prevalence-adjusted and bias-adjusted κ (PABAK) coefficients of test and grader reliability. CD was correctly identified on FP 88.9% of the time and correctly identified as not being present 83.3% of the time. CD was correctly identified on FAF 62.0% of the time and correctly identified as not being present 100.0% of the time. Compared with FA, FP has a PABAK of 0.75 (0.60 to 1.5) and FAF a PABAK of 0.44 (0.23 to 0.95). FP is a promising, non-invasive substitute for FA in the diagnosis of CD. FAF was less reliable than FP to detect CD. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. Effect of isoproterenol, phenylephrine, and sodium nitroprusside on fundus pulsations in healthy volunteers.

    OpenAIRE

    Schmetterer, L; Wolzt, M; Salomon, A; Rheinberger, A; Unfried, C; Zanaschka, G; Fercher, A F

    1996-01-01

    AIMS/BACKGROUND: Recently a laser interferometric method for topical measurement of fundus pulsations has been developed. Fundus pulsations in the macular region are caused by the inflow and outflow of blood into the choroid. The purpose of this work was to study the influence of a peripheral vasoconstricting (the alpha 1 adrenoceptor agonist phenylephrine), a predominantly positive inotropic (the non-specific beta adrenoceptor agonist isoproterenol), and a non-specific vasodilating (sodium n...

  3. Ophthalmoscopy versus non-mydriatic fundus photography in the ...

    African Journals Online (AJOL)

    The contribution of non-mydriatic fundus photography in the detection of diabetic retinopathy before and after dilatation of the pupils in black diabetics was investigated and compared with direct ophthalmoscopy. Eighty-six patients were examined and good-quality photographs were obtained for 54,7% of eyes before and ...

  4. Drusen regression is associated with local changes in fundus autofluorescence in intermediate age-related macular degeneration.

    Science.gov (United States)

    Toy, Brian C; Krishnadev, Nupura; Indaram, Maanasa; Cunningham, Denise; Cukras, Catherine A; Chew, Emily Y; Wong, Wai T

    2013-09-01

    To investigate the association of spontaneous drusen regression in intermediate age-related macular degeneration (AMD) with changes on fundus photography and fundus autofluorescence (FAF) imaging. Prospective observational case series. Fundus images from 58 eyes (in 58 patients) with intermediate AMD and large drusen were assessed over 2 years for areas of drusen regression that exceeded the area of circle C1 (diameter 125 μm; Age-Related Eye Disease Study grading protocol). Manual segmentation and computer-based image analysis were used to detect and delineate areas of drusen regression. Delineated regions were graded as to their appearance on fundus photographs and FAF images, and changes in FAF signal were graded manually and quantitated using automated image analysis. Drusen regression was detected in approximately half of study eyes using manual (48%) and computer-assisted (50%) techniques. At year-2, the clinical appearance of areas of drusen regression on fundus photography was mostly unremarkable, with a majority of eyes (71%) demonstrating no detectable clinical abnormalities, and the remainder (29%) showing minor pigmentary changes. However, drusen regression areas were associated with local changes in FAF that were significantly more prominent than changes on fundus photography. A majority of eyes (64%-66%) demonstrated a predominant decrease in overall FAF signal, while 14%-21% of eyes demonstrated a predominant increase in overall FAF signal. FAF imaging demonstrated that drusen regression in intermediate AMD was often accompanied by changes in local autofluorescence signal. Drusen regression may be associated with concurrent structural and physiologic changes in the outer retina. Published by Elsevier Inc.

  5. Subretinal Fibrosis in Stargardt’s Disease with Fundus Flavimaculatus and ABCA4 Gene Mutation

    Directory of Open Access Journals (Sweden)

    Settimio Rossi

    2012-12-01

    Full Text Available Purpose: To report on 4 patients affected by Stargardt’s disease (STGD with fundus flavimaculatus (FFM and ABCA4 gene mutation associated with subretinal fibrosis. Methods: Four patients with a diagnosis of STGD were clinically examined. All 4 cases underwent a full ophthalmologic evaluation, including best-corrected visual acuity measured by the Snellen visual chart, biomicroscopic examination, fundus examination, fundus photography, electroretinogram, microperimetry, optical coherence tomography and fundus autofluorescence. All patients were subsequently screened for ABCA4 gene mutations, identified by microarray genotyping and confirmed by conventional DNA sequencing of the relevant exons. Results: In all 4 patients, ophthalmologic exam showed areas of subretinal fibrosis in different retinal sectors. In only 1 case, these lesions were correlated to an ocular trauma as confirmed by biomicroscopic examination of the anterior segment that showed a nuclear cataract dislocated to the superior site and vitreous opacities along the lens capsule. The other patients reported a lifestyle characterized by competitive sport activities. The performed instrumental diagnostic investigations confirmed the diagnosis of STGD with FFM in all patients. Moreover, in all 4 affected individuals, mutations in the ABCA4 gene were found. Conclusions: Patients with the diagnosis of STGD associated with FFM can show atypical fundus findings. We report on 4 patients affected by STGD with ABCA4 gene mutation associated with subretinal fibrosis. Our findings suggest that this phenomenon can be accelerated by ocular trauma and also by ocular microtrauma caused by sport activities, highlighting that lifestyle can play a role in the onset of these lesions.

  6. Reliability and reproducibility of disc-foveal angle measurements by non-mydriatic fundus photography

    OpenAIRE

    Le Jeune, Caroline; Chebli, Fayçal; Leon, Lorette; Anthoine, Emmanuelle; Weber, Michel; Péchereau, Alain; Lebranchu, Pierre

    2018-01-01

    Purpose Abnormal torsion could be associated with cyclovertical strabismus, but torsion measurements are not reliable in children. To assess an objective fundus torsion evaluation in a paediatric population, we used Non-Mydriatic Fundus photography (NMFP) in healthy and cyclovertical strabismus patients to evaluate the disc-foveal angle over time and observers. Methods We used a retrospective set of NMFP including 24 A or V-pattern strabismus and 27 age-matched normal children (mean age 6.4 a...

  7. IDENTIFICATION OF DIGITAL COMPETENCES SKILLS IN TEACHER TRAINING DEGREE STUDENTS

    Directory of Open Access Journals (Sweden)

    Margarita Pino Juste

    2010-11-01

    Full Text Available The Technologies of Information and Communication (ICT become in the information society a change agent. In this context, ICTs should become teaching tools in order to help the teacher to achieve quality education.Being aware of the importance of the teachers' mastery of the digital skills, we have conducted a study about the mastery of the ICTs that the students in the third year of the degree of teacher training of the University of Vigo have. In order to do this we have taken into account the knowledge acquired, the frequency of use of certain tools, their level of proficiency in four areas of knowledge: technological literacy, intellectual working tools, processing and dissemination of information and as communication tools. As well as their motivations, interests and obstacles found in their development in order to develop proposals for initial training.We can conclude that, in general, students do not have a specific training on the use of computers. About the degree of knowledge in the different skills, the students know the most basic and commonly used (open or download a file, create or print a document, install a program or send an e-mail. They usually use the mail as a working tool, while the messaging and social networks are more used for leisure time.Their attitudes towards ICTs are very positive and their motivations are focused essentially on the technologies which are useful for improving their learning and for their professional future.

  8. Differential gene expression in the murine gastric fundus lacking interstitial cells of Cajal

    Directory of Open Access Journals (Sweden)

    Ward Sean M

    2003-06-01

    Full Text Available Abstract Background The muscle layers of murine gastric fundus have no interstitial cells of Cajal at the level of the myenteric plexus and only possess intramuscular interstitial cells and this tissue does not generate electric slow waves. The absence of intramuscular interstitial cells in W/WV mutants provides a unique opportunity to study the molecular changes that are associated with the loss of these intercalating cells. Method The gene expression profile of the gastric fundus of wild type and W/WV mice was assayed by murine microarray analysis displaying a total of 8734 elements. Queried genes from the microarray analysis were confirmed by semi-quantitative reverse transcription-polymerase chain reaction. Results Twenty-one genes were differentially expressed in wild type and W/WV mice. Eleven transcripts had 2.0–2.5 fold higher mRNA expression in W/WV gastric fundus when compared to wild type tissues. Ten transcripts had 2.1–3.9 fold lower expression in W/WV mutants in comparison with wild type animals. None of these genes have ever been implicated in any bowel motility function. Conclusions These data provides evidence that several important genes have significantly changed in the murine fundus of W/WV mutants that lack intramuscular interstitial cells of Cajal and have reduced enteric motor neurotransmission.

  9. Automated diagnosis of diabetic retinopathy and glaucoma using fundus and OCT images

    Directory of Open Access Journals (Sweden)

    Pachiyappan Arulmozhivarman

    2012-06-01

    Full Text Available Abstract We describe a system for the automated diagnosis of diabetic retinopathy and glaucoma using fundus and optical coherence tomography (OCT images. Automatic screening will help the doctors to quickly identify the condition of the patient in a more accurate way. The macular abnormalities caused due to diabetic retinopathy can be detected by applying morphological operations, filters and thresholds on the fundus images of the patient. Early detection of glaucoma is done by estimating the Retinal Nerve Fiber Layer (RNFL thickness from the OCT images of the patient. The RNFL thickness estimation involves the use of active contours based deformable snake algorithm for segmentation of the anterior and posterior boundaries of the retinal nerve fiber layer. The algorithm was tested on a set of 89 fundus images of which 85 were found to have at least mild retinopathy and OCT images of 31 patients out of which 13 were found to be glaucomatous. The accuracy for optical disk detection is found to be 97.75%. The proposed system therefore is accurate, reliable and robust and can be realized.

  10. Comparison of film and digital fundus photographs in eyes of individuals with diabetes mellitus

    DEFF Research Database (Denmark)

    Gangaputra, Sapna; Almukhtar, Talat; Glassman, Adam R

    2011-01-01

    To compare grading of diabetic retinopathy (DR) and diabetic macular edema (DME) from stereoscopic film versus stereoscopic digital photographs obtained from a subset of Diabetic Retinopathy Clinical Research Network (DRCR.net) participants.......To compare grading of diabetic retinopathy (DR) and diabetic macular edema (DME) from stereoscopic film versus stereoscopic digital photographs obtained from a subset of Diabetic Retinopathy Clinical Research Network (DRCR.net) participants....

  11. Fundus autofluorescence features of optic disc pit related maculopathy

    African Journals Online (AJOL)

    Fundus autoflorescence (FAF) is a new investigational tool used to identify lipofuscin distribution in the retinal pigment epithelium (RPE) cell monolayer. It has recently been used to analyze age‑related macular degeneration, central serous chorioretinopathy, retina telangiectasia and diffuse and macula retina dystrophies.

  12. [Follow-up on MEWDS by fundus perimetry and multifocal ERG with the SLO].

    Science.gov (United States)

    Bültmann, S; Martin, M; Rohrschneider, K

    2002-09-01

    Most conventional techniques for examination such as perimetry or ERG may not be sensitive enough to detect functional alterations due to MEWDS precisely. We report on a follow-up performed by fundus perimetry and the new technique of multifocal ERG using the scanning laser ophthalmoscope. A 24-year-old female patient (VA 0.2/0.8) was followed up for 7 weeks with these techniques as well as Octopus perimetry, fluorescence angiography, Ganzfeld ERG and biomicroscopy. Multifocal ERG stimulation (mfERG, Retiscan) was performed with the SLO. Visual acuity improved from 0.2 to 0.8 and the central relative scotoma disappeared while a relevant increase of P1-wave amplitudes in mfERG could be observed. Combining objective measurements from the fundus controlled SLO-mfERG and results from fundus perimetry enable good correlation of morphology and results, even for minor alterations of the macula only accessible by few established clinical examinations.

  13. Development of a screening tool for staging of diabetic retinopathy in fundus images

    Science.gov (United States)

    Dhara, Ashis Kumar; Mukhopadhyay, Sudipta; Bency, Mayur Joseph; Rangayyan, Rangaraj M.; Bansal, Reema; Gupta, Amod

    2015-03-01

    Diabetic retinopathy is a condition of the eye of diabetic patients where the retina is damaged because of long-term diabetes. The condition deteriorates towards irreversible blindness in extreme cases of diabetic retinopathy. Hence, early detection of diabetic retinopathy is important to prevent blindness. Regular screening of fundus images of diabetic patients could be helpful in preventing blindness caused by diabetic retinopathy. In this paper, we propose techniques for staging of diabetic retinopathy in fundus images using several shape and texture features computed from detected microaneurysms, exudates, and hemorrhages. The classification accuracy is reported in terms of the area (Az) under the receiver operating characteristic curve using 200 fundus images from the MESSIDOR database. The value of Az for classifying normal images versus mild, moderate, and severe nonproliferative diabetic retinopathy (NPDR) is 0:9106. The value of Az for classification of mild NPDR versus moderate and severe NPDR is 0:8372. The Az value for classification of moderate NPDR and severe NPDR is 0:9750.

  14. Color Fundus Photography versus Fluorescein Angiography in Identification of the Macular Center and Zone in Retinopathy of Prematurity

    Science.gov (United States)

    Patel, Samir N.; Klufas, Michael A.; Ryan, Michael C.; Jonas, Karyn E.; Ostmo, Susan; Martinez-Castellanos, Maria Ana; Berrocal, Audina M.; Chiang, Michael F.; Chan, R.V. Paul

    2016-01-01

    Purpose To examine the utility of fluorescein angiography (FA) in identification of the macular center and the diagnosis of zone in patients with retinopathy of prematurity (ROP). Design Validity and reliability analysis of diagnostic tools Methods 32 sets (16 color fundus photographs; 16 color fundus photographs paired with the corresponding FA) of wide-angle retinal images obtained from 16 eyes of eight infants with ROP were compiled on a secure web site. 9 ROP experts (3 pediatric ophthalmologists; 6 vitreoretinal surgeons) participated in the study. For each image set, experts identified the macular center and provided a diagnosis of zone. Main Outcome Measures (1) Sensitivity and specificity of zone diagnosis (2) “Computer facilitated diagnosis of zone,” based on precise measurement of the macular center, optic disc center, and peripheral ROP. Results Computer facilitated diagnosis of zone agreed with the expert’s diagnosis of zone in 28/45 (62%) cases using color fundus photographs and in 31/45 (69%) cases using FA. Mean (95% CI) sensitivity for detection of zone I by experts as compared to a consensus reference standard diagnosis when interpreting the color fundus images alone versus interpreting the color fundus photographs and FA was 47% (35.3% – 59.3%) and 61.1% (48.9% – 72.4%), respectively, (t(9) ≥ (2.063), p = 0.073). Conclusions There is a marginally significant difference in zone diagnosis when using color fundus photographs compared to using color fundus photographs and the corresponding fluorescein angiograms. There is inconsistency between traditional zone diagnosis (based on ophthalmoscopic exam and image review) compared to a computer-facilitated diagnosis of zone. PMID:25637180

  15. [Fundus autofluorescence in dry AMD - impact on disease progression].

    Science.gov (United States)

    Vidinova, C N; Gouguchkova, P T; Vidinov, K N

    2013-11-01

    Fundus autofluorescence is a novel technique that gives us information about the RPE cells by evaluating the distribution of lipofuscin in the retina. The purpose of our study was to evaluate the diagnostic abilities of OCT, RTVue and fundus autofluorescence in predicting the progression of dry AMD. In our study 37 dry AMD patients were enrolled: 22 of them with druses and 15 with developed geographic atrophy. They all underwent complete ophthalmological examinations including OCT and autofluorescence. We used the RTVue OCT programmes HD line, Cross line, EMM5 and EMM5 progression in all cases. The autofluorescence was recorded with the help of the Canon CX1 fundus camera. OCT images in the AMD patients with dry AMD and large druses showed typical undulations in the RPE/choroid line and occasionally drusenoid detachment of the RPE. Autofluorescence showed different patterns. The confluent reticular autofluorescence was associated with the development of neovascular membranes. In geographic atrophy patient OCTs showed diminished retinal thickness measured with EMM5. On autofluorescence the findings at the border zone atrophic/normal retina were of particular importance. The diffuse increased autofluorescence in that area was considered to be a sign for further atrophy progression. Our results point out that OCT in combination with autofluorescence is important in following the progression of dry AMD. Pathological autofluorescence at the border of atrophic lesions is an important sign for disease activity. Although both OCT and autofluorescence visualise the changes in RPE, autofluorescence is of key importance in predicting the development of the disease. Georg Thieme Verlag KG Stuttgart · New York.

  16. Joint optic disc and cup boundary extraction from monocular fundus images.

    Science.gov (United States)

    Chakravarty, Arunava; Sivaswamy, Jayanthi

    2017-08-01

    Accurate segmentation of optic disc and cup from monocular color fundus images plays a significant role in the screening and diagnosis of glaucoma. Though optic cup is characterized by the drop in depth from the disc boundary, most existing methods segment the two structures separately and rely only on color and vessel kink based cues due to the lack of explicit depth information in color fundus images. We propose a novel boundary-based Conditional Random Field formulation that extracts both the optic disc and cup boundaries in a single optimization step. In addition to the color gradients, the proposed method explicitly models the depth which is estimated from the fundus image itself using a coupled, sparse dictionary trained on a set of image-depth map (derived from Optical Coherence Tomography) pairs. The estimated depth achieved a correlation coefficient of 0.80 with respect to the ground truth. The proposed segmentation method outperformed several state-of-the-art methods on five public datasets. The average dice coefficient was in the range of 0.87-0.97 for disc segmentation across three datasets and 0.83 for cup segmentation on the DRISHTI-GS1 test set. The method achieved a good glaucoma classification performance with an average AUC of 0.85 for five fold cross-validation on RIM-ONE v2. We propose a method to jointly segment the optic disc and cup boundaries by modeling the drop in depth between the two structures. Since our method requires a single fundus image per eye during testing it can be employed in the large-scale screening of glaucoma where expensive 3D imaging is unavailable. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Automatic computer-aided diagnosis of retinal nerve fiber layer defects using fundus photographs in optic neuropathy.

    Science.gov (United States)

    Oh, Ji Eun; Yang, Hee Kyung; Kim, Kwang Gi; Hwang, Jeong-Min

    2015-05-01

    To evaluate the validity of an automatic computer-aided diagnosis (CAD) system for detection of retinal nerve fiber layer (RNFL) defects on fundus photographs of glaucomatous and nonglaucomatous optic neuropathy. We have proposed an automatic detection method for RNFL defects on fundus photographs in various cases of glaucomatous and nonglaucomatous optic neuropathy. In order to detect the vertical dark bands as candidate RNFL defects, the nonuniform illumination of the fundus image was corrected, the blood vessels were removed, and the images were converted to polar coordinates with the center of the optic disc. False positives (FPs) were reduced by using knowledge-based rules. The sensitivity and FP rates for all images were calculated. We tested 98 fundus photographs with 140 RNFL defects and 100 fundus photographs of healthy normal subjects. The proposed method achieved a sensitivity of 90% and a 0.67 FP rate per image and worked well with RNFL defects with variable depths and widths, with uniformly high detection rates regardless of the angular widths of the RNFL defects. The average detection accuracy was approximately 0.94. The overall diagnostic accuracy of the proposed algorithm for detecting RNFL defects among 98 patients and 100 healthy individuals was 86% sensitivity and 75% specificity. The proposed CAD system successfully detected RNFL defects in optic neuropathies. Thus, the proposed algorithm is useful for the detection of RNFL defects.

  18. [Fundus Autofluorescence Imaging].

    Science.gov (United States)

    Schmitz-Valckenberg, S

    2015-09-01

    Fundus autofluorescence (FAF) imaging allows for non-invasive mapping of changes at the level of the retinal pigment epithelium/photoreceptor complex and of alterations of macular pigment distribution. This imaging method is based on the visualisation of intrinsic fluorophores and may be easily and rapidly used in routine patient care. Main applications include degenerative disorders of the outer retina such as age-related macular degeneration, hereditary and acquired retinal diseases. FAF imaging is particularly helpful for differential diagnosis, detection and extent of involved retinal areas, structural-functional correlations and monitoring of changes over time. Recent developments include - in addition to the original application of short wavelength light for excitation ("blue" FAF imaging) - the use of other wavelength ranges ("green" or "near-infrared" FAF imaging), widefield imaging for visualisation of peripheral retinal areas and quantitative FAF imaging. Georg Thieme Verlag KG Stuttgart · New York.

  19. Incidence of fundus oculi and neurocranium changes in patients with migraine in the community

    Directory of Open Access Journals (Sweden)

    M. Musić

    2005-02-01

    Full Text Available The purpose of this study was to monitor possible changes of fundus oculi and neurocranim in patients with migraine according to their gender, place of residence and education grade. In a significantpercentageofourpatients with migraine there were no changes of fundus oculi, CT neurocranium or craniogram. The reason of significantmigrainemorbidityinruralzones,inpatientswithlowereducationgrade,andalmostequalproportionof male and female patients with tendency of the disease to older age groups, remains unclear. There is a need for further research.

  20. Early simultaneous fundus autofluorescence and optical coherence tomography features after pars plana vitrectomy for primary rhegmatogenous retinal detachment.

    Science.gov (United States)

    Dell'Omo, Roberto; Mura, Marco; Lesnik Oberstein, Sarit Y; Bijl, Heico; Tan, H Stevie

    2012-04-01

    To describe fundus autofluorescence and optical coherence tomography (OCT) features of the macula after pars plana vitrectomy for rhegmatogenous retinal detachment. Thirty-three eyes of 33 consecutive patients with repaired rhegmatogenous retinal detachment with or without the involvement of the macula were prospectively investigated with simultaneous fundus autofluorescence and OCT imaging using the Spectralis HRA+OCT (Heidelberg Engineering, Heidelberg, Germany) within a few weeks after the operation. Fundus autofluorescence imaging of the macula showed lines of increased and decreased autofluorescence in 19 cases (57.6%). On OCT, these lines corresponded to the following abnormalities: outer retinal folds, inner retinal folds, and skip reflectivity abnormalities of the photoreceptor inner segment/outer segment band. Other OCT findings, not related to abnormal lines on fundus autofluorescence, consisted of disruption of photoreceptor inner segment/outer segment band and collection of intraretinal or subretinal fluid. The presence of outer retinal folds significantly related to metamorphopsia but did not relate to poor postoperative visual acuity. Partial-thickness retinal folds occur commonly after vitrectomy for rhegmatogenous retinal detachment repair and may represent an important anatomical substrate for postoperative metamorphopsia. Fundus autofluorescence and OCT are both sensitive techniques for the detection of these abnormalities.

  1. Enhanced depth imaging optical coherence tomography and fundus autofluorescence findings in bilateral choroidal osteoma: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Erol, Muhammet Kazim; Coban, Deniz Turgut; Ceran, Basak Bostanci; Bulut, Mehmet, E-mail: muhammetkazimerol@gmail.com [Kazim Erol. Antalya Training and Research Hospital, Ophthalmology Department, Antalya (Turkey)

    2013-11-01

    The authors present enhanced depth imaging optical coherence tomography (EDI OCT) and fundus autofluorescence (FAF) characteristics of a patient with bilateral choroidal osteoma and try to make a correlation between two imaging techniques. Two eyes of a patient with choroidal osteoma underwent complete ophthalmic examination. Enhanced depth imaging optical coherence tomography revealed a cage-like pattern, which corresponded to the calcified region of the tumor. Fundus autofluorescence imaging of the same area showed slight hyperautofluorescence. Three different reflectivity patterns in the decalcified area were defined. In the areas of subretinal fluid, outer segment elongations similar to central serous chorioretinopathy were observed. Hyperautofluorescent spots were evident in fundus autofluorescence in the same area. Calcified and decalcified portions of choroidal osteoma as well as the atrophy of choriocapillaris demonstrated different patterns with enhanced depth imaging and fundus autofluorescence imaging. Both techniques were found to be beneficial in the diagnosis and follow-up of choroidal osteoma. (author)

  2. Enhanced depth imaging optical coherence tomography and fundus autofluorescence findings in bilateral choroidal osteoma: a case report

    International Nuclear Information System (INIS)

    Erol, Muhammet Kazim; Coban, Deniz Turgut; Ceran, Basak Bostanci; Bulut, Mehmet

    2013-01-01

    The authors present enhanced depth imaging optical coherence tomography (EDI OCT) and fundus autofluorescence (FAF) characteristics of a patient with bilateral choroidal osteoma and try to make a correlation between two imaging techniques. Two eyes of a patient with choroidal osteoma underwent complete ophthalmic examination. Enhanced depth imaging optical coherence tomography revealed a cage-like pattern, which corresponded to the calcified region of the tumor. Fundus autofluorescence imaging of the same area showed slight hyperautofluorescence. Three different reflectivity patterns in the decalcified area were defined. In the areas of subretinal fluid, outer segment elongations similar to central serous chorioretinopathy were observed. Hyperautofluorescent spots were evident in fundus autofluorescence in the same area. Calcified and decalcified portions of choroidal osteoma as well as the atrophy of choriocapillaris demonstrated different patterns with enhanced depth imaging and fundus autofluorescence imaging. Both techniques were found to be beneficial in the diagnosis and follow-up of choroidal osteoma. (author)

  3. Enhanced depth imaging optical coherence tomography and fundus autofluorescence findings in bilateral choroidal osteoma: a case report

    Directory of Open Access Journals (Sweden)

    Muhammet Kazim Erol

    2013-06-01

    Full Text Available The authors present enhanced depth imaging optical coherence tomography (EDI OCT and fundus autofluorescence (FAF characteristics of a patient with bilateral choroidal osteoma and try to make a correlation between two imaging techniques. Two eyes of a patient with choroidal osteoma underwent complete ophthalmic examination. Enhanced depth imaging optical coherence tomography revealed a cage-like pattern, which corresponded to the calcified region of the tumor. Fundus autofluorescence imaging of the same area showed slight hyperautofluorescence. Three different reflectivity patterns in the decalcified area were defined. In the areas of subretinal fluid, outer segment elongations similar to central serous chorioretinopathy were observed. Hyperautofluorescent spots were evident in fundus autofluorescence in the same area. Calcified and decalcified portions of choroidal osteoma as well as the atrophy of choriocapillaris demonstrated different patterns with enhanced depth imaging and fundus autofluorescence imaging. Both techniques were found to be beneficial in the diagnosis and follow-up of choroidal osteoma.

  4. Quantitative fundus autofluorescence in healthy eyes.

    Science.gov (United States)

    Greenberg, Jonathan P; Duncker, Tobias; Woods, Russell L; Smith, R Theodore; Sparrow, Janet R; Delori, François C

    2013-08-21

    Fundus autofluorescence was quantified (qAF) in subjects with healthy retinae using a standardized approach. The objective was to establish normative data and identify factors that influence the accumulation of RPE lipofuscin and/or modulate the observed AF signal in fundus images. AF images were acquired from 277 healthy subjects (age range: 5-60 years) by employing a Spectralis confocal scanning laser ophthalmoscope (cSLO; 488-nm excitation; 30°) equipped with an internal fluorescent reference. For each image, mean gray level was calculated as the average of eight preset regions, and was calibrated to the reference, zero-laser light, magnification, and optical media density from normative data on lens transmission spectra. Relationships between qAF and age, sex, race/ethnicity, eye color, refraction/axial length, and smoking status were evaluated as was measurement repeatability and the qAF spatial distribution. qAF levels exhibited a significant increase with age. qAF increased with increasing eccentricity up to 10° to 15° from the fovea and was highest superotemporally. qAF values were significantly greater in females, and, compared with Hispanics, qAF was significantly higher in whites and lower in blacks and Asians. No associations with axial length and smoking were observed. For two operators, between-session repeatability was ± 9% and ± 12%. Agreement between the operators was ± 13%. Normative qAF data are a reference tool essential to the interpretation of qAF measurements in ocular disease.

  5. Ultra-wide field imaging system and traditional retinal examinations for screening fundus changes after cataract surgery.

    Science.gov (United States)

    Peng, Jie; Zhang, Qi; Jin, Hai-Ying; Lu, Wu-Yi; Zhao, Pei-Quan

    2016-01-01

    To compare the results of non-mydriatic ultra-wide field imaging system, mydriatic slit-lamp lens (Volk +90 D) and mydriatic Goldmann three-mirror contact lens examinations in screening fundus lesions among patients after cataract surgery. Non-mydriatic images were obtained with an Optomap panoramic 200Tx (Optomap 200Tx) 3d after surgery and graded by a blinded ophthalmologist. A mydriatic slit-lamp lens examination was performed by another blinded retinal specialist on the same day. A third blinded retinal specialist examined patients two weeks after surgery using a Goldmann three-mirror contact lens. In total, 160 patients (184 eyes) were examined, and 66, 69, and 75 cases of retinal lesion(s) were identified using the Optomap 200Tx, slit-lamp lens, and Goldmann three-mirror contact lens, respectively. In 13 cases, fundus changes were sight-threatening. The results obtained by Optomap 200Tx examination and by mydriatic slit-lamp lens examination have good consistency (P=0.375, Kappa=0.942). The mydriatic Goldmann three-mirror lens examination revealed more fundus lesions but are consistent with Optomap 200Tx (P=0.004, Kappa=0.897) and mydriatic slit-lamp lens examination (P=0.031, Kappa=0.932). Early post-operative fundus screening in cataract patients is extremely important and necessary to prevent further vision loss. Wide-field imaging is a feasible and convenient tool for fundus examination that can be used as a primary screening method among patients after cataract surgery.

  6. 数码彩色眼底照相对糖尿病视网膜病变早期诊断模式的研究%Role of Ocular Fundus Imaging in Research of Early Diagnostic Mode for Diabetic Retinopathy

    Institute of Scientific and Technical Information of China (English)

    王中颖

    2012-01-01

    目的 采用直接眼底镜检查、数码彩色眼底照相、荧光素眼底血管造影及光学相干断层扫描等4种方法,对糖尿病视网膜病变患者进行检查和评估,探讨早期糖尿病视网膜病变筛查方法.方法 对2009年1月~2010年1月就诊我院眼科门诊的糖尿病患者,进行直接眼底镜检查、数码彩色眼底照相、荧光素眼底血管造影及光学相干断层扫描检查.以荧光素眼底血管造影诊断为标准,分析各种检查结果的敏感性、特异性及与眼底荧光血管造影诊断的一致性.结果 以糖尿病视网膜病变l期为筛查阈值时,眼底彩色照相的敏感性、特异性均明显高于直接眼底镜检查,Kappa检验有高度一致性;以糖尿病视网膜病变2期为筛查阈值时,直接眼底镜检查与眼底彩色照相的特异性基本一致,但眼底彩色照相的敏感性明显高于直接眼底镜检查,Kappa检验有高度一致性.同正常组相比,糖尿病视网膜病变1期视网膜各方位厚度并无明显增加,糖尿病视网膜病变2期各方位神经上皮层厚度比相应方位的正常组增加.结论 数码彩色眼底照相可作为糖尿病视网膜病变2期以上患者的主要筛查诊断方法.%Objective Diabetic retinopathy (DR) in patients with diabetic mellitus (DM) are estimated and detected through direct funduscopy, digital fundus imaging, fundus fluorescein angiography (FFA) and optical coherence tomography (OCT). Methods All diabetes who received examination in ophthalmic outpatient department of our hospital underwent direct funduscopy, digital fundus imaging, FFA and OCX, Then taking the diagnosis of FFA as the standard, we could not only analyse the sensitivity and specificity, but also analyse consistency diagnosed by FFA, Macular thickness in all the quadrants and foveal volume were evaluated. Results When diabetic retinopathy in first stage is being taken as referable DR threshold, ocular digital fundus imaging gave

  7. Optic disc boundary segmentation from diffeomorphic demons registration of monocular fundus image sequences versus 3D visualization of stereo fundus image pairs for automated early stage glaucoma assessment

    Science.gov (United States)

    Gatti, Vijay; Hill, Jason; Mitra, Sunanda; Nutter, Brian

    2014-03-01

    Despite the current availability in resource-rich regions of advanced technologies in scanning and 3-D imaging in current ophthalmology practice, world-wide screening tests for early detection and progression of glaucoma still consist of a variety of simple tools, including fundus image-based parameters such as CDR (cup to disc diameter ratio) and CAR (cup to disc area ratio), especially in resource -poor regions. Reliable automated computation of the relevant parameters from fundus image sequences requires robust non-rigid registration and segmentation techniques. Recent research work demonstrated that proper non-rigid registration of multi-view monocular fundus image sequences could result in acceptable segmentation of cup boundaries for automated computation of CAR and CDR. This research work introduces a composite diffeomorphic demons registration algorithm for segmentation of cup boundaries from a sequence of monocular images and compares the resulting CAR and CDR values with those computed manually by experts and from 3-D visualization of stereo pairs. Our preliminary results show that the automated computation of CDR and CAR from composite diffeomorphic segmentation of monocular image sequences yield values comparable with those from the other two techniques and thus may provide global healthcare with a cost-effective yet accurate tool for management of glaucoma in its early stage.

  8. FUNDUS AUTOFLUORESCENCE IN RUBELLA RETINOPATHY: Correlation With Photoreceptor Structure and Function.

    Science.gov (United States)

    Bukowska, Danuta M; Wan, Sue Ling; Chew, Avenell L; Chelva, Enid; Tang, Ivy; Mackey, David A; Chen, Fred K

    2017-01-01

    To illustrate altered fundus autofluorescence in rubella retinopathy and to investigate their relationships with photoreceptor structure and function using multimodal imaging. The authors report four cases of rubella retinopathy aged 8, 33, 42, and 50 years. All patients had dilated clinical fundus examination; wide-field color photography; blue, green, and near-infrared autofluorescence imaging and spectral domain optical coherence tomography. Two patients also underwent microperimetry and adaptive optics imaging. En face optical coherence tomography, cone mosaic, and microperimetry were coregistered with autofluorescence images. The authors explored the structure-function correlation. All four patients had a "salt-and-pepper" appearance on dilated fundus examination and wide-field color photography. There were variable-sized patches of hypoautofluorescence on both blue and near-infrared excitation in all four patients. Wave-guiding cones were visible and retinal sensitivity was intact over these regions. There was no correlation between hypoautofluorescence and regions of attenuated ellipsoid and interdigitation zones. Hyperautofluorescent lesions were also noted and some of these were pseudo-vitelliform lesions. Patchy hypoautofluorescence on near-infrared excitation can be a feature of rubella retinopathy. This may be due to abnormal melanin production or loss of melanin within retinal pigment epithelium cells harboring persistent rubella virus infection. Preservation of the ellipsoid zone, wave-guiding cones, and retinal sensitivity within hypoautofluorescent lesions suggest that these retinal pigment epithelium changes have only mild impact on photoreceptor cell function.

  9. Fundus Findings in Wernicke Encephalopathy

    Directory of Open Access Journals (Sweden)

    Tal Serlin

    2017-07-01

    Full Text Available Wernicke encephalopathy (WE is an acute neuropsychiatric syndrome resulting from thiamine (vitamin B1 deficiency, classically characterized by the triad of ophthalmoplegia, confusion, and ataxia. While commonly associated with chronic alcoholism, WE may also occur in the setting of poor nutrition or absorption. We present a 37-year-old woman who underwent laparoscopic sleeve gastrectomy and presented with visual disturbance with bilateral horizontal nystagmus, confusion, and postural imbalance. Fundus examination revealed bilateral optic disc edema with a retinal hemorrhage in the left eye. Metabolic workup demonstrated thiamine deficiency. Her symptoms resolved after thiamine treatment. This case raises the awareness of the possibility of posterior segment findings in WE, which are underreported in WE.

  10. [Evaluation of fundus autofluorescence in hereditary retinal diseases using Heidelberg Retina Angiograph2].

    Science.gov (United States)

    Côco, Monique; Baba, Natalia Tamie; Sallum, Juliana Maria Ferraz

    2007-01-01

    To define characteristics of the fundus autofluorescence examination, verifying usefulness in the diagnosis and care of hereditary retinal diseases. 28 patients, adults, divided equally into four groups with diagnoses of Stargardt macular dystrophy, cone dystrophy, retinitis pigmentosa and healthy volunteers for the establishment of the normality pattern. An average of nine images with the filter for fluorescein angiography was obtained for the formation of the image autofluorescence using Heidelberg Retina Angiograph2. The images of each group of patients were analyzed to verify common characteristics. The fundus autofluorescence of healthy volunteers showed the foveal area darker than the surrounding retina. The images of Stargardt macular dystrophy, in general, presented an oval central lesion, with reduced autofluorescence. The main alterations of the autofluorescence in patients with cone dystrophy were reduced foveal autofluorescence with a parafoveal ring of increased autofluorescence. In general, the images of retinitis pigmentosa showed outlying pigments with reduced autofluorescence, and of the foveal area, in some cases disorganization or reduced autofluorescence. The study showed the existence of patterns of fundus autofluorescence in the hereditary retinal diseases that allow the diagnosis and better interpretation of the pathogenesis of these diseases.

  11. Reliability and reproducibility of disc-foveal angle measurements by non-mydriatic fundus photography.

    Science.gov (United States)

    Le Jeune, Caroline; Chebli, Fayçal; Leon, Lorette; Anthoine, Emmanuelle; Weber, Michel; Péchereau, Alain; Lebranchu, Pierre

    2018-01-01

    Abnormal torsion could be associated with cyclovertical strabismus, but torsion measurements are not reliable in children. To assess an objective fundus torsion evaluation in a paediatric population, we used Non-Mydriatic Fundus photography (NMFP) in healthy and cyclovertical strabismus patients to evaluate the disc-foveal angle over time and observers. We used a retrospective set of NMFP including 24 A or V-pattern strabismus and 27 age-matched normal children (mean age 6.4 and 6.7 years respectively), taken during 2 distinct follow-up consultations (separated by 251 and 479 days respectively). Each disc-foveal angle measurement (from which the ocular torsion can be assessed) was performed by 5 different observers, using graphical software and based on reproducible fundus anatomical marks. Statistical analysis was performed with a multivariate ANOVA using group, time and observers as factors, in addition to intraclass coefficient correlation (ICC) to assess measurement reproducibility. A significant difference of disc-foveal angle measures was observed between groups (p0,97). Abnormal amount of objective torsion could be associated with alphabet-pattern strabismus. Disc-foveal angle evaluation by NMFP in a children population appears as a non-invasive, reliable and reproducible method.

  12. Matching fundus photographs of classmates. An informal competition to promote learning and practice of direct ophthalmoscopy among medical students.

    Science.gov (United States)

    Krohn, Jørgen; Kjersem, Bård; Høvding, Gunnar

    2014-05-01

    To present a new approach for teaching direct ophthalmoscopy to medical students. At the University of Bergen, four consecutive classes of fourth-year medical students complete a required 9-week ophthalmology course every year. In the present project, one fundus photograph was taken of each student. The photographs were randomly numbered, printed on A4 glossy photo paper, and displayed on the classroom wall. Each student was given a form to fill in the fellow students' names matching the number of the fundus photographs. They were encouraged to practise direct ophthalmoscopy on their classmates outside formal teaching hours. At the end of the course, they returned the filled-in forms, and those with the highest number of correct matches between the fundus photographs and fellow students received a reward. Between 2011 and 2013, 239 students completed their ophthalmology course. Of these, 220 students (92%) voluntarily participated in the project. The mean score was 70% correct matches between fundus photographs and fellow students (range 7 - 100%). The students' course evaluations were overall positive. We recommend the use of peer fundus photographs in the context of a learning competition as a simple, inexpensive, and effective way to improve teaching of direct ophthalmoscopy.

  13. Trans-palpebral illumination: an approach for wide-angle fundus photography without the need for pupil dilation

    OpenAIRE

    Toslak, Devrim; Thapa, Damber; Chen, Yanjun; Erol, Muhammet Kazim; Paul Chan, R. V.; Yao, Xincheng

    2016-01-01

    It is technically difficult to construct wide-angle fundus imaging devices due to the complexity of conventional transpupillary illumination and imaging mechanisms. We report here a new method, i.e., trans-palpebral illumination, for wide-angle fundus photography without the need for pupil dilation. By constructing a smartphone-based prototype imaging device, we demonstrated a 152° view in a single-shot image. The unique combination of low-cost smartphone design and automatic illumination opt...

  14. Fundus Autofluorescence Imaging in an Ocular Screening Program

    Directory of Open Access Journals (Sweden)

    A. M. Kolomeyer

    2012-01-01

    Full Text Available Purpose. To describe integration of fundus autofluorescence (FAF imaging into an ocular screening program. Methods. Fifty consecutive screening participants were included in this prospective pilot imaging study. Color and FAF (530/640 nm exciter/barrier filters images were obtained with a 15.1MP Canon nonmydriatic hybrid camera. A clinician evaluated the images on site to determine need for referral. Visual acuity (VA, intraocular pressure (IOP, and ocular pathology detected by color fundus and FAF imaging modalities were recorded. Results. Mean ± SD age was 47.4 ± 17.3 years. Fifty-two percent were female and 58% African American. Twenty-seven percent had a comprehensive ocular examination within the past year. Mean VA was 20/39 in the right eye and 20/40 in the left eye. Mean IOP was 15 mmHg bilaterally. Positive color and/or FAF findings were identified in nine (18% individuals with diabetic retinopathy or macular edema (n=4, focal RPE defects (n=2, age-related macular degeneration (n=1, central serous retinopathy (n=1, and ocular trauma (n=1. Conclusions. FAF was successfully integrated in our ocular screening program and aided in the identification of ocular pathology. Larger studies examining the utility of this technology in screening programs may be warranted.

  15. Fundus autofluorescence imaging in an ocular screening program.

    Science.gov (United States)

    Kolomeyer, A M; Nayak, N V; Szirth, B C; Khouri, A S

    2012-01-01

    Purpose. To describe integration of fundus autofluorescence (FAF) imaging into an ocular screening program. Methods. Fifty consecutive screening participants were included in this prospective pilot imaging study. Color and FAF (530/640 nm exciter/barrier filters) images were obtained with a 15.1MP Canon nonmydriatic hybrid camera. A clinician evaluated the images on site to determine need for referral. Visual acuity (VA), intraocular pressure (IOP), and ocular pathology detected by color fundus and FAF imaging modalities were recorded. Results. Mean ± SD age was 47.4 ± 17.3 years. Fifty-two percent were female and 58% African American. Twenty-seven percent had a comprehensive ocular examination within the past year. Mean VA was 20/39 in the right eye and 20/40 in the left eye. Mean IOP was 15 mmHg bilaterally. Positive color and/or FAF findings were identified in nine (18%) individuals with diabetic retinopathy or macular edema (n = 4), focal RPE defects (n = 2), age-related macular degeneration (n = 1), central serous retinopathy (n = 1), and ocular trauma (n = 1). Conclusions. FAF was successfully integrated in our ocular screening program and aided in the identification of ocular pathology. Larger studies examining the utility of this technology in screening programs may be warranted.

  16. Automated segmentation of geographic atrophy of the retinal epithelium via random forests in AREDS color fundus images☆

    Science.gov (United States)

    Feeny, Albert K.; Tadarati, Mongkol; Freund, David E.; Bressler, Neil M.; Burlina, Philippe

    2015-01-01

    Background Age-related macular degeneration (AMD), left untreated, is the leading cause of vision loss in people older than 55. Severe central vision loss occurs in the advanced stage of the disease, characterized by either the in growth of choroidal neovascularization (CNV), termed the “wet” form, or by geographic atrophy (GA) of the retinal pigment epithelium (RPE) involving the center of the macula, termed the “dry” form. Tracking the change in GA area over time is important since it allows for the characterization of the effectiveness of GA treatments. Tracking GA evolution can be achieved by physicians performing manual delineation of GA area on retinal fundus images. However, manual GA delineation is time-consuming and subject to inter-and intra-observer variability. Methods We have developed a fully automated GA segmentation algorithm in color fundus images that uses a supervised machine learning approach employing a random forest classifier. This algorithm is developed and tested using a dataset of images from the NIH-sponsored Age Related Eye Disease Study (AREDS). GA segmentation output was compared against a manual delineation by a retina specialist. Results Using 143 color fundus images from 55 different patient eyes, our algorithm achieved PPV of 0.82±0.19, and NPV of 0:95±0.07. Discussion This is the first study, to our knowledge, applying machine learning methods to GA segmentation on color fundus images and using AREDS imagery for testing. These preliminary results show promising evidence that machine learning methods may have utility in automated characterization of GA from color fundus images. PMID:26318113

  17. Automated segmentation of geographic atrophy of the retinal epithelium via random forests in AREDS color fundus images.

    Science.gov (United States)

    Feeny, Albert K; Tadarati, Mongkol; Freund, David E; Bressler, Neil M; Burlina, Philippe

    2015-10-01

    Age-related macular degeneration (AMD), left untreated, is the leading cause of vision loss in people older than 55. Severe central vision loss occurs in the advanced stage of the disease, characterized by either the in growth of choroidal neovascularization (CNV), termed the "wet" form, or by geographic atrophy (GA) of the retinal pigment epithelium (RPE) involving the center of the macula, termed the "dry" form. Tracking the change in GA area over time is important since it allows for the characterization of the effectiveness of GA treatments. Tracking GA evolution can be achieved by physicians performing manual delineation of GA area on retinal fundus images. However, manual GA delineation is time-consuming and subject to inter-and intra-observer variability. We have developed a fully automated GA segmentation algorithm in color fundus images that uses a supervised machine learning approach employing a random forest classifier. This algorithm is developed and tested using a dataset of images from the NIH-sponsored Age Related Eye Disease Study (AREDS). GA segmentation output was compared against a manual delineation by a retina specialist. Using 143 color fundus images from 55 different patient eyes, our algorithm achieved PPV of 0.82±0.19, and NPV of 0:95±0.07. This is the first study, to our knowledge, applying machine learning methods to GA segmentation on color fundus images and using AREDS imagery for testing. These preliminary results show promising evidence that machine learning methods may have utility in automated characterization of GA from color fundus images. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. An automated and robust image processing algorithm for glaucoma diagnosis from fundus images using novel blood vessel tracking and bend point detection.

    Science.gov (United States)

    M, Soorya; Issac, Ashish; Dutta, Malay Kishore

    2018-02-01

    Glaucoma is an ocular disease which can cause irreversible blindness. The disease is currently identified using specialized equipment operated by optometrists manually. The proposed work aims to provide an efficient imaging solution which can help in automating the process of Glaucoma diagnosis using computer vision techniques from digital fundus images. The proposed method segments the optic disc using a geometrical feature based strategic framework which improves the detection accuracy and makes the algorithm invariant to illumination and noise. Corner thresholding and point contour joining based novel methods are proposed to construct smooth contours of Optic Disc. Based on a clinical approach as used by ophthalmologist, the proposed algorithm tracks blood vessels inside the disc region and identifies the points at which first vessel bend from the optic disc boundary and connects them to obtain the contours of Optic Cup. The proposed method has been compared with the ground truth marked by the medical experts and the similarity parameters, used to determine the performance of the proposed method, have yield a high similarity of segmentation. The proposed method has achieved a macro-averaged f-score of 0.9485 and accuracy of 97.01% in correctly classifying fundus images. The proposed method is clinically significant and can be used for Glaucoma screening over a large population which will work in a real time. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Fundus autofluorescence patterns in primary intraocular lymphoma.

    Science.gov (United States)

    Casady, Megan; Faia, Lisa; Nazemzadeh, Maryam; Nussenblatt, Robert; Chan, Chi-Chao; Sen, H Nida

    2014-02-01

    To evaluate fundus autofluorescence (FAF) patterns in patients with primary intraocular (vitreoretinal) lymphoma. Records of all patients with primary intraocular lymphoma who underwent FAF imaging at the National Eye Institute were reviewed. Fundus autofluorescence patterns were evaluated with respect to clinical disease status and the findings on fluorescein angiography and spectral-domain optical coherence tomography. There were 18 eyes (10 patients) with primary intraocular lymphoma that underwent FAF imaging. Abnormal autofluorescence in the form of granular hyperautofluorescence and hypoautofluorescence was seen in 11 eyes (61%), and blockage by mass lesion was seen in 2 eyes (11%). All eyes with granular pattern on FAF had active primary intraocular lymphoma at the time of imaging, but there were 5 eyes with unremarkable FAF, which were found to have active lymphoma. The most common pattern on fluorescein angiography was hypofluorescent round spots with a "leopard spot" appearance (43%). These hypofluorescent spots on fluorescein angiography correlated with hyperautofluorescent spots on FAF in 5 eyes (36%) (inversion of FAF). Nodular hyperreflective spots at the level of retinal pigment epithelium on optical coherence tomography were noted in 43% of eyes. The hyperautofluorescent spots on FAF correlated with nodular hyperreflective spots on optical coherence tomography in 6 eyes (43%). Granularity on FAF was associated with active lymphoma in majority of the cases. An inversion of FAF (hyperautofluorescent spots on FAF corresponding to hypofluorescent spots on fluorescein angiography) was observed in less than half of the eyes.

  20. Interpretations of Fundus Autofluorescence from Studies of the Bisretinoids of the Retina

    OpenAIRE

    Sparrow, Janet R.; Yoon, Kee Dong; Wu, Yalin; Yamamoto, Kazunori

    2010-01-01

    Elevated fundus autofluorescence signals can reflect enhanced lipofuscin in RPE cells, augmented fluorescence due to photooxidation, and/or excess bisretinoid fluorophores in photoreceptor cells due to mishandling of vitamin A aldehyde by dysfunctional cells.

  1. Retro-mode imaging and fundus autofluorescence with scanning laser ophthalmoscope of retinal dystrophies

    Directory of Open Access Journals (Sweden)

    Maurizio Battaglia

    2012-05-01

    Full Text Available Abstract Background Retinal dystrophies display a considerably wide range of phenotypic variability, which can make diagnosis and clinical staging difficult. The aim of the study is to analyze the contribution of retro-mode imaging (RMI and fundus autofluorescence (FAF to the characterization of retinal dystrophies. Methods Eighteen consecutive patients affected by retinal dystrophies underwent a complete ophthalmological examination, including best corrected visual acuity with ETDRS charts, blue-light fundus autofluorescence, (BL-FAF, near-infrared fundus autofluorescence (NIR-FAF, and RMI. The primary outcome was the identification of abnormal patterns on RMI. The secondary outcome was the correlation with the findings on BL-FAF and NIR-FAF. Results Overall, the main feature of RMI is represented by a pseudo-3D pattern of all the lesions at the posterior pole. More specifically, any accumulation of material within the retina appears as an area of elevation of different shape and size, displaying irregular and darker borders. No precise correlations between RMI, BL-AF, and NIR-AF imaging was found. Conclusions RMI and FAF appear to be useful tools for characterizing retinal dystrophies. Non-invasive diagnostic tools may yield additional information on the clinical setting and the monitoring of the patients.

  2. Segmentasi Pembuluh Darah Retina Pada Citra Fundus Menggunakan Gradient Based Adaptive Thresholding Dan Region Growing

    Directory of Open Access Journals (Sweden)

    Deni Sutaji

    2016-07-01

    Full Text Available AbstrakSegmentasi pembuluh darah pada citra fundus retina menjadi hal yang substansial dalam dunia kedokteran, karena dapat digunakan untuk mendeteksi penyakit, seperti: diabetic retinopathy, hypertension, dan cardiovascular. Dokter membutuhkan waktu sekitar dua jam untuk mendeteksi pembuluh darah retina, sehingga diperlukan metode yang dapat membantu screening agar lebih cepat.Penelitian sebelumnya mampu melakukan segmentasi pembuluh darah yang sensitif terhadap variasi ukuran lebar pembuluh darah namun masih terjadi over-segmentasi pada area patologi. Oleh karena itu, penelitian ini bertujuan untuk mengembangkan metode segmentasi pembuluh darah pada citra fundus retina yang dapat mengurangi over-segmentasi pada area patologi menggunakan Gradient Based Adaptive Thresholding dan Region Growing.Metode yang diusulkan terdiri dari 3 tahap, yaitu segmentasi pembuluh darah utama, deteksi area patologi dan segmentasi pembuluh darah tipis. Tahap segmentasi pembuluh darah utama menggunakan high-pass filtering dan tophat reconstruction pada kanal hijau citra yang sudah diperbaiki kontrasnya sehingga lebih jelas perbedaan antara pembuluh darah dan background. Tahap deteksi area patologi menggunakan metode Gradient Based Adaptive Thresholding. Tahap segmentasi pembuluh darah tipis menggunakan Region Growing berdasarkan informasi label pembuluh darah utama dan label area patologi. Hasil segmentasi pembuluh darah utama dan pembuluh darah tipis kemudian digabungkan sehingga menjadi keluaran sistem berupa citra biner pembuluh darah. Berdasarkan hasil uji coba, metode ini mampu melakukan segmentasi pembuluh darah retina dengan baik pada citra fundus DRIVE, yaitu dengan akurasi rata-rata 95.25% dan nilai Area Under Curve (AUC pada kurva Relative Operating Characteristic (ROC sebesar 74.28%.                           Kata Kunci: citra fundus retina, gradient based adaptive thresholding, patologi, pembuluh darah retina, region growing

  3. Analysis of visual appearance of retinal nerve fibers in high resolution fundus images: a study on normal subjects.

    Science.gov (United States)

    Kolar, Radim; Tornow, Ralf P; Laemmer, Robert; Odstrcilik, Jan; Mayer, Markus A; Gazarek, Jiri; Jan, Jiri; Kubena, Tomas; Cernosek, Pavel

    2013-01-01

    The retinal ganglion axons are an important part of the visual system, which can be directly observed by fundus camera. The layer they form together inside the retina is the retinal nerve fiber layer (RNFL). This paper describes results of a texture RNFL analysis in color fundus photographs and compares these results with quantitative measurement of RNFL thickness obtained from optical coherence tomography on normal subjects. It is shown that local mean value, standard deviation, and Shannon entropy extracted from the green and blue channel of fundus images are correlated with corresponding RNFL thickness. The linear correlation coefficients achieved values 0.694, 0.547, and 0.512 for respective features measured on 439 retinal positions in the peripapillary area from 23 eyes of 15 different normal subjects.

  4. Nitrergic Pathway Is the Main Contributing Mechanism in the Human Gastric Fundus Relaxation: An In Vitro Study.

    Directory of Open Access Journals (Sweden)

    Yang Won Min

    Full Text Available Human gastric fundus relaxation is mediated by intrinsic inhibitory pathway. We investigated the roles of nitrergic and purinergic pathways, two known inhibitory factors in gastric motility, on spontaneous and nerve-evoked contractions in human gastric fundus muscles.Gastric fundus muscle strips (12 circular and 13 longitudinal were obtained from patients without previous gastrointestinal motility disorder who underwent gastrectomy for stomach cancer. Using these specimens, we examined basal tone, peak, amplitude, and frequency of spontaneous contractions, and peak and nadir values under electrical field stimulation (EFS, 150 V, 0.3 ms, 10 Hz, 20 s. To examine responses to purinergic and nitrergic inhibition without cholinergic innervation, atropine (muscarinic antagonist, 1 μM, MRS2500 (a purinergic P2Y1 receptor antagonist, 1 μM, and N-nitro-L-arginine (L-NNA, a nitric oxide synthase inhibitor, 100 μM were added sequentially for spontaneous and electrically-stimulated contractions. Tetrodotoxin was used to confirm any neuronal involvement.In spontaneous contraction, L-NNA increased basal tone and peak in both muscle layers, while amplitude and frequency were unaffected. EFS (up to 10 Hz uniformly induced initial contraction and subsequent relaxation in a frequency-dependent manner. Atropine abolished initial on-contraction and induced only relaxation during EFS. While MRS2500 showed no additional influence, L-NNA reversed relaxation (p = 0.012 in circular muscle, and p = 0.006 in longitudinal muscle. Tetrodotoxin abolished any EFS-induced motor response.The relaxation of human gastric fundus muscle is reduced by nitrergic inhibition. Hence, nitrergic pathway appears to be the main mechanism for the human gastric fundus relaxation.

  5. Unusual optical coherence tomography and fundus autofluorescence findings of eclipse retinopathy

    Directory of Open Access Journals (Sweden)

    Kun-Hsien Li

    2012-01-01

    Full Text Available A 63-year-old female patient complained of dimness in the central field of vision in the left eye after viewing an annular partial eclipse without adequate eye protection on 22 July 2009. Fundoscopy showed a wrinkled macular surface. Fundus autofluorescence study revealed well-demarcated hyperautofluorescence at the fovea. Optical coherence tomography demonstrated tiny intraretinal cysts. Fluorescein angiography and indocyanine green angiography were unremarkable. Epimacular membrane developed in the following month with deteriorated vision. Vitrectomy, epiretinal membrane and internal limiting membrane peeling were performed. Vision was restored to 20/20 after the operation. Direct sun-gazing may damage the retinal structures resulting in macular inflammation and increased focal metabolism, which explains the hyperautofluorescence. It may also induce epimacular membrane. Fundus autofluorescence might represent a useful technique to detect subtle solar-induced injuries of the retina. The visual prognosis is favorable but prevention remains the mainstay of treatment. Public health education is mandatory in reducing visual morbidity.

  6. Analysis of Visual Appearance of Retinal Nerve Fibers in High Resolution Fundus Images: A Study on Normal Subjects

    Directory of Open Access Journals (Sweden)

    Radim Kolar

    2013-01-01

    Full Text Available The retinal ganglion axons are an important part of the visual system, which can be directly observed by fundus camera. The layer they form together inside the retina is the retinal nerve fiber layer (RNFL. This paper describes results of a texture RNFL analysis in color fundus photographs and compares these results with quantitative measurement of RNFL thickness obtained from optical coherence tomography on normal subjects. It is shown that local mean value, standard deviation, and Shannon entropy extracted from the green and blue channel of fundus images are correlated with corresponding RNFL thickness. The linear correlation coefficients achieved values 0.694, 0.547, and 0.512 for respective features measured on 439 retinal positions in the peripapillary area from 23 eyes of 15 different normal subjects.

  7. Thickness related textural properties of retinal nerve fiber layer in color fundus images.

    Science.gov (United States)

    Odstrcilik, Jan; Kolar, Radim; Tornow, Ralf-Peter; Jan, Jiri; Budai, Attila; Mayer, Markus; Vodakova, Martina; Laemmer, Robert; Lamos, Martin; Kuna, Zdenek; Gazarek, Jiri; Kubena, Tomas; Cernosek, Pavel; Ronzhina, Marina

    2014-09-01

    Images of ocular fundus are routinely utilized in ophthalmology. Since an examination using fundus camera is relatively fast and cheap procedure, it can be used as a proper diagnostic tool for screening of retinal diseases such as the glaucoma. One of the glaucoma symptoms is progressive atrophy of the retinal nerve fiber layer (RNFL) resulting in variations of the RNFL thickness. Here, we introduce a novel approach to capture these variations using computer-aided analysis of the RNFL textural appearance in standard and easily available color fundus images. The proposed method uses the features based on Gaussian Markov random fields and local binary patterns, together with various regression models for prediction of the RNFL thickness. The approach allows description of the changes in RNFL texture, directly reflecting variations in the RNFL thickness. Evaluation of the method is carried out on 16 normal ("healthy") and 8 glaucomatous eyes. We achieved significant correlation (normals: ρ=0.72±0.14; p≪0.05, glaucomatous: ρ=0.58±0.10; p≪0.05) between values of the model predicted output and the RNFL thickness measured by optical coherence tomography, which is currently regarded as a standard glaucoma assessment device. The evaluation thus revealed good applicability of the proposed approach to measure possible RNFL thinning. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.

    Science.gov (United States)

    Li, Zhixi; He, Yifan; Keel, Stuart; Meng, Wei; Chang, Robert T; He, Mingguang

    2018-03-02

    To assess the performance of a deep learning algorithm for detecting referable glaucomatous optic neuropathy (GON) based on color fundus photographs. A deep learning system for the classification of GON was developed for automated classification of GON on color fundus photographs. We retrospectively included 48 116 fundus photographs for the development and validation of a deep learning algorithm. This study recruited 21 trained ophthalmologists to classify the photographs. Referable GON was defined as vertical cup-to-disc ratio of 0.7 or more and other typical changes of GON. The reference standard was made until 3 graders achieved agreement. A separate validation dataset of 8000 fully gradable fundus photographs was used to assess the performance of this algorithm. The area under receiver operator characteristic curve (AUC) with sensitivity and specificity was applied to evaluate the efficacy of the deep learning algorithm detecting referable GON. In the validation dataset, this deep learning system achieved an AUC of 0.986 with sensitivity of 95.6% and specificity of 92.0%. The most common reasons for false-negative grading (n = 87) were GON with coexisting eye conditions (n = 44 [50.6%]), including pathologic or high myopia (n = 37 [42.6%]), diabetic retinopathy (n = 4 [4.6%]), and age-related macular degeneration (n = 3 [3.4%]). The leading reason for false-positive results (n = 480) was having other eye conditions (n = 458 [95.4%]), mainly including physiologic cupping (n = 267 [55.6%]). Misclassification as false-positive results amidst a normal-appearing fundus occurred in only 22 eyes (4.6%). A deep learning system can detect referable GON with high sensitivity and specificity. Coexistence of high or pathologic myopia is the most common cause resulting in false-negative results. Physiologic cupping and pathologic myopia were the most common reasons for false-positive results. Copyright © 2018 American Academy of Ophthalmology. Published by

  9. Digitization errors using digital charge division positionsensitive detectors

    International Nuclear Information System (INIS)

    Berliner, R.; Mildner, D.F.R.; Pringle, O.A.

    1981-01-01

    The data acquisition speed and electronic stability of a charge division position-sensitive detector may be improved by using digital signal processing with a table look-up high speed multiply to form the charge division quotient. This digitization process introduces a positional quantization difficulty which reduces the detector position sensitivity. The degree of the digitization error is dependent on the pulse height spectrum of the detector and on the resolution or dynamic range of the system analog-to-digital converters. The effects have been investigated analytically and by computer simulation. The optimum algorithm for position sensing determination using 8-bit digitization and arithmetic has a digitization error of less than 1%. (orig.)

  10. Multimodal segmentation of optic disc and cup from stereo fundus and SD-OCT images

    Science.gov (United States)

    Miri, Mohammad Saleh; Lee, Kyungmoo; Niemeijer, Meindert; Abràmoff, Michael D.; Kwon, Young H.; Garvin, Mona K.

    2013-03-01

    Glaucoma is one of the major causes of blindness worldwide. One important structural parameter for the diagnosis and management of glaucoma is the cup-to-disc ratio (CDR), which tends to become larger as glaucoma progresses. While approaches exist for segmenting the optic disc and cup within fundus photographs, and more recently, within spectral-domain optical coherence tomography (SD-OCT) volumes, no approaches have been reported for the simultaneous segmentation of these structures within both modalities combined. In this work, a multimodal pixel-classification approach for the segmentation of the optic disc and cup within fundus photographs and SD-OCT volumes is presented. In particular, after segmentation of other important structures (such as the retinal layers and retinal blood vessels) and fundus-to-SD-OCT image registration, features are extracted from both modalities and a k-nearest-neighbor classification approach is used to classify each pixel as cup, rim, or background. The approach is evaluated on 70 multimodal image pairs from 35 subjects in a leave-10%-out fashion (by subject). A significant improvement in classification accuracy is obtained using the multimodal approach over that obtained from the corresponding unimodal approach (97.8% versus 95.2%; p < 0:05; paired t-test).

  11. Detection of exudates in fundus imagery using a constant false-alarm rate (CFAR) detector

    Science.gov (United States)

    Khanna, Manish; Kapoor, Elina

    2014-05-01

    Diabetic retinopathy is the leading cause of blindness in adults in the United States. The presence of exudates in fundus imagery is the early sign of diabetic retinopathy so detection of these lesions is essential in preventing further ocular damage. In this paper we present a novel technique to automatically detect exudates in fundus imagery that is robust against spatial and temporal variations of background noise. The detection threshold is adjusted dynamically, based on the local noise statics around the pixel under test in order to maintain a pre-determined, constant false alarm rate (CFAR). The CFAR detector is often used to detect bright targets in radar imagery where the background clutter can vary considerably from scene to scene and with angle to the scene. Similarly, the CFAR detector addresses the challenge of detecting exudate lesions in RGB and multispectral fundus imagery where the background clutter often exhibits variations in brightness and texture. These variations present a challenge to common, global thresholding detection algorithms and other methods. Performance of the CFAR algorithm is tested against a publicly available, annotated, diabetic retinopathy database and preliminary testing suggests that performance of the CFAR detector proves to be superior to techniques such as Otsu thresholding.

  12. Application of 3-dimensional printing technology to construct an eye model for fundus viewing study.

    Directory of Open Access Journals (Sweden)

    Ping Xie

    Full Text Available To construct a life-sized eye model using the three-dimensional (3D printing technology for fundus viewing study of the viewing system.We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs. Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D printing. Together with the main printed structure, polymethyl methacrylate(PMMA aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy.In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value.The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research.

  13. Application of 3-dimensional printing technology to construct an eye model for fundus viewing study.

    Science.gov (United States)

    Xie, Ping; Hu, Zizhong; Zhang, Xiaojun; Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai

    2014-01-01

    To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical design software. With computer aided design (CAD) software, we designed the 3D digital model of the main structure of the physical model eye, which was used for three-dimensional (3D) printing. Together with the main printed structure, polymethyl methacrylate(PMMA) aspherical cornea, variable iris, and IOLs were assembled to a physical eye model. Angle scale bars were glued from posterior to periphery of the retina. Then we fabricated other three physical models with different states of ammetropia. Optical parameters of these physical eye models were measured to verify the 3D printing accuracy. In on-axis calculations, our schematic model eye possessed similar size of spot diagram compared with Navarro's and Bakaraju's model eye, much smaller than Arianpour's model eye. Moreover, the spherical aberration of our schematic eye was much less than other three model eyes. While in off- axis simulation, it possessed a bit higher coma and similar astigmatism, field curvature and distortion. The MTF curves showed that all the model eyes diminished in resolution with increasing field of view, and the diminished tendency of resolution of our physical eye model was similar to the Navarro's eye. The measured parameters of our eye models with different status of ametropia were in line with the theoretical value. The schematic eye model we designed can well simulate the optical performance of the human eye, and the fabricated physical one can be used as a tool in fundus range viewing research.

  14. Detailed Morphological Changes of Foveoschisis in Patient with X-Linked Retinoschisis Detected by SD-OCT and Adaptive Optics Fundus Camera

    Directory of Open Access Journals (Sweden)

    Keiichiro Akeo

    2015-01-01

    Full Text Available Purpose. To report the morphological and functional changes associated with a regression of foveoschisis in a patient with X-linked retinoschisis (XLRS. Methods. A 42-year-old man with XLRS underwent genetic analysis and detailed ophthalmic examinations. Functional assessments included best-corrected visual acuity (BCVA, full-field electroretinograms (ERGs, and multifocal ERGs (mfERGs. Morphological assessments included fundus photography, spectral-domain optical coherence tomography (SD-OCT, and adaptive optics (AO fundus imaging. After the baseline clinical data were obtained, topical dorzolamide was applied to the patient. The patient was followed for 24 months. Results. A reported RS1 gene mutation was found (P203L in the patient. At the baseline, his decimal BCVA was 0.15 in the right and 0.3 in the left eye. Fundus photographs showed bilateral spoke wheel-appearing maculopathy. SD-OCT confirmed the foveoschisis in the left eye. The AO images of the left eye showed spoke wheel retinal folds, and the folds were thinner than those in fundus photographs. During the follow-up period, the foveal thickness in the SD-OCT images and the number of retinal folds in the AO images were reduced. Conclusions. We have presented the detailed morphological changes of foveoschisis in a patient with XLRS detected by SD-OCT and AO fundus camera. However, the findings do not indicate whether the changes were influenced by topical dorzolamide or the natural history.

  15. Evaluation of an online peer fundus photograph matching program in teaching direct ophthalmoscopy to medical students.

    Science.gov (United States)

    Kwok, Jason; Liao, Walter; Baxter, Stephanie

    2017-10-01

    Direct ophthalmoscopy is an important clinical skill that is often poorly performed by medical professionals and students. This is attributable to a declining emphasis on ophthalmology in medical school. We present and evaluate a self-directed approach of teaching ophthalmoscopy to medical students that is suitable for the current medical curriculum. Prospective medical education trial. Ninety-five second-year medical students at Queen's University: 32 in the experimental group and 63 in the control group. The experimental group consisted of medical students who practised ophthalmoscopy with one another using an online peer fundus photograph matching exercise created by the Department of Ophthalmology at Queen's University. To use the program, students first examined a peer with an ophthalmoscope and then selected an online photograph of a fundus corresponding to that of the examinee. The program notifies students if a correct selection is made. To encourage use of the program, students participated in a 2-week ophthalmoscopy competition during their ophthalmology rotation. The control group consisted of students who did not participate in the learning exercise. On assessment at the end of the ophthalmology rotation, the experimental group (n = 32) was more accurate in matching fundus photographs compared with the control group (n = 63) (p = 0.02). Participants were faster at performing ophthalmoscopy at the end of the learning exercise (p peer fundus photographs in a self-directed manner appeared to increase the skill and confidence of medical students in ophthalmoscopy. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  16. Modification of a Kowa RC-2 fundus camera for self-photography without the use of mydriatics.

    Science.gov (United States)

    Philpott, D E; Bailey, P F; Harrison, G; Turnbill, C

    1979-01-01

    Research on retinal circulation during space flight required the development of a simple technique to provide self monitoring of blood vessel changes in the fundus without the use of mydriatics. A Kowa RC-2 fundus camera was modified for self-photography by the use of a bite plate for positioning and cross hairs for focusing the subject's retina relative to the film plane. Dilation of the pupils without the use of mydriatics was accomplished by dark adaption of the subject. Pictures were obtained without pupil constriction by the use of a high speed strobe light. This method also has applications for clinical medicine.

  17. Interactive segmentation for geographic atrophy in retinal fundus images

    OpenAIRE

    Lee, Noah; Smith, R. Theodore; Laine, Andrew F.

    2008-01-01

    Fundus auto-fluorescence (FAF) imaging is a non-invasive technique for in vivo ophthalmoscopic inspection of age-related macular degeneration (AMD), the most common cause of blindness in developed countries. Geographic atrophy (GA) is an advanced form of AMD and accounts for 12–21% of severe visual loss in this disorder [3]. Automatic quantification of GA is important for determining disease progression and facilitating clinical diagnosis of AMD. The problem of automatic segmentation of patho...

  18. Six-degree-of-freedom missile simulation using the ADI AD 100 digital computer and ADSIM simulation language

    Science.gov (United States)

    Zwaanenburg, Koos

    1989-01-01

    The use of an AD 100 computer and the ADSIM language in the six-degree-of-freedom digital simulation of an air-to-ground missile is illustrated. The missile is launched from a moving platform, typically a helicopter, and is capable of striking a mobile target up to 10 kilometers away. The missile could be any tactical missile. The performance numbers of the AD 100 show that it is possible to implement a high performance missile model in a real-time simulation without the problems associated with an implementation on a general purpose computer using FORTRAN.

  19. Detection of retinal nerve fiber layer defects in retinal fundus images using Gabor filtering

    Science.gov (United States)

    Hayashi, Yoshinori; Nakagawa, Toshiaki; Hatanaka, Yuji; Aoyama, Akira; Kakogawa, Masakatsu; Hara, Takeshi; Fujita, Hiroshi; Yamamoto, Tetsuya

    2007-03-01

    Retinal nerve fiber layer defect (NFLD) is one of the most important findings for the diagnosis of glaucoma reported by ophthalmologists. However, such changes could be overlooked, especially in mass screenings, because ophthalmologists have limited time to search for a number of different changes for the diagnosis of various diseases such as diabetes, hypertension and glaucoma. Therefore, the use of a computer-aided detection (CAD) system can improve the results of diagnosis. In this work, a technique for the detection of NFLDs in retinal fundus images is proposed. In the preprocessing step, blood vessels are "erased" from the original retinal fundus image by using morphological filtering. The preprocessed image is then transformed into a rectangular array. NFLD regions are observed as vertical dark bands in the transformed image. Gabor filtering is then applied to enhance the vertical dark bands. False positives (FPs) are reduced by a rule-based method which uses the information of the location and the width of each candidate region. The detected regions are back-transformed into the original configuration. In this preliminary study, 71% of NFLD regions are detected with average number of FPs of 3.2 per image. In conclusion, we have developed a technique for the detection of NFLDs in retinal fundus images. Promising results have been obtained in this initial study.

  20. A Deep Learning Algorithm for Prediction of Age-Related Eye Disease Study Severity Scale for Age-Related Macular Degeneration from Color Fundus Photography.

    Science.gov (United States)

    Grassmann, Felix; Mengelkamp, Judith; Brandl, Caroline; Harsch, Sebastian; Zimmermann, Martina E; Linkohr, Birgit; Peters, Annette; Heid, Iris M; Palm, Christoph; Weber, Bernhard H F

    2018-04-10

    Age-related macular degeneration (AMD) is a common threat to vision. While classification of disease stages is critical to understanding disease risk and progression, several systems based on color fundus photographs are known. Most of these require in-depth and time-consuming analysis of fundus images. Herein, we present an automated computer-based classification algorithm. Algorithm development for AMD classification based on a large collection of color fundus images. Validation is performed on a cross-sectional, population-based study. We included 120 656 manually graded color fundus images from 3654 Age-Related Eye Disease Study (AREDS) participants. AREDS participants were >55 years of age, and non-AMD sight-threatening diseases were excluded at recruitment. In addition, performance of our algorithm was evaluated in 5555 fundus images from the population-based Kooperative Gesundheitsforschung in der Region Augsburg (KORA; Cooperative Health Research in the Region of Augsburg) study. We defined 13 classes (9 AREDS steps, 3 late AMD stages, and 1 for ungradable images) and trained several convolution deep learning architectures. An ensemble of network architectures improved prediction accuracy. An independent dataset was used to evaluate the performance of our algorithm in a population-based study. κ Statistics and accuracy to evaluate the concordance between predicted and expert human grader classification. A network ensemble of 6 different neural net architectures predicted the 13 classes in the AREDS test set with a quadratic weighted κ of 92% (95% confidence interval, 89%-92%) and an overall accuracy of 63.3%. In the independent KORA dataset, images wrongly classified as AMD were mainly the result of a macular reflex observed in young individuals. By restricting the KORA analysis to individuals >55 years of age and prior exclusion of other retinopathies, the weighted and unweighted κ increased to 50% and 63%, respectively. Importantly, the algorithm

  1. Two-photon excited fluorescence microscopy application for ex vivo investigation of ocular fundus samples

    Science.gov (United States)

    Peters, Sven; Hammer, Martin; Schweitzer, Dietrich

    2011-07-01

    Two-photon excited fluorescence (TPEF) imaging of ocular tissue has recently become a promising tool in ophthalmology for diagnostic and research purposes. The feasibility and the advantages of TPEF imaging, namely deeper tissue penetration and improved high-resolution imaging of microstructures, have been demonstrated lately using human ocular samples. The autofluorescence properties of endogenous fluorophores in ocular fundus tissue are well known from spectrophotometric analysis. But fluorophores, especially when it comes to fluorescence lifetime, typically display a dependence of their fluorescence properties on local environmental parameters. Hence, a more detailed investigation of ocular fundus autofluorescence ideally in vivo is of utmost interest. The aim of this study is to determine space-resolved the stationary and time-resolved fluorescence properties of endogenous fluorophores in ex vivo porcine ocular fundus samples by means of two-photon excited fluorescence spectrum and lifetime imaging microscopy (FSIM/FLIM). By our first results, we characterized the autofluorescence of individual anatomical structures of porcine retina samples excited at 760 nm. The fluorescence properties of almost all investigated retinal layers are relatively homogenous. But as previously unknown, ganglion cell bodies show a significantly shorter fluorescence lifetime compared to the adjacent mueller cells. Since all retinal layers exhibit bi-exponential autofluorescence decays, we were able to achieve a more precise characterization of fluorescence properties of endogenous fluorophores compared to a present in vivo FLIM approach by confocal scanning laser ophthalmoscope (cSLO).

  2. Detection of retinal capillary nonperfusion in fundus fluorescein angiogram of diabetic retinopathy.

    Science.gov (United States)

    Rasta, Seyed Hossein; Nikfarjam, Shima; Javadzadeh, Alireza

    2015-01-01

    Retinal capillary nonperfusion (CNP) is one of the retinal vascular diseases in diabetic retinopathy (DR) patients. As there is no comprehensive detection technique to recognize CNP areas, we proposed a different method for computing detection of ischemic retina, non-perfused (NP) regions, in fundus fluorescein angiogram (FFA) images. Whilst major vessels appear as ridges, non-perfused areas are usually observed as ponds that are surrounded by healthy capillaries in FFA images. A new technique using homomorphic filtering to correct light illumination and detect the ponds surrounded in healthy capillaries on FFA images was designed and applied on DR fundus images. These images were acquired from the diabetic patients who had referred to the Nikookari hospital and were diagnosed for diabetic retinopathy during one year. Our strategy was screening the whole image with a fixed window size, which is small enough to enclose areas with identified topographic characteristics. To discard false nominees, we also performed a thresholding operation on the screen and marked images. To validate its performance we applied our detection algorithm on 41 FFA diabetic retinopathy fundus images in which the CNP areas were manually delineated by three clinical experts. Lesions were found as smooth regions with very high uniformity, low entropy, and small intensity variations in FFA images. The results of automated detection method were compared with manually marked CNP areas so achieved sensitivity of 81%, specificity of 78%, and accuracy of 91%.The result was present as a Receiver operating character (ROC) curve, which has an area under the curve (AUC) of 0.796 with 95% confidence intervals. This technique introduced a new automated detection algorithm to recognize non-perfusion lesions on FFA. This has potential to assist detecting and managing of ischemic retina and may be incorporated into automated grading diabetic retinopathy structures.

  3. A comparison of cup-to-disc ratio estimates by fundus biomicroscopy and stereoscopic optic disc photography in the Tema Eye Survey.

    Science.gov (United States)

    Mwanza, J C; Grover, D S; Budenz, D L; Herndon, L W; Nolan, W; Whiteside-de Vos, J; Hay-Smith, G; Bandi, J R; Bhansali, K A; Forbes, L A; Feuer, W J; Barton, K

    2017-08-01

    PurposeTo determine if there are systematic differences in cup-to-disc ratio (CDR) grading using fundus biomicroscopy compared to stereoscopic disc photograph reading.MethodsThe vertical cup-to-disc ratio (VCDR) and horizontal cup-to-disc ratio (HCDR) of 2200 eyes (testing set) were graded by glaucoma subspecialists through fundus biomicroscopy and by a reading center using stereoscopic disc photos. For validation, the glaucoma experts also estimated VCDR and HCDR using stereoscopic disc photos in a subset of 505 eyes that they had assessed biomicroscopically. Agreement between grading methods was assessed with Bland-Altman plots.ResultsIn both sets, photo reading tended to yield small CDRs marginally larger, but read large CDRs marginally smaller than fundus biomicroscopy. The mean differences in VCDR and HCDR were 0.006±0.18 and 0.05±0.18 (testing set), and -0.053±0.23 and -0.028±0.21 (validation set), respectively. The limits of agreement were ~0.4, which is twice as large as the cutoff of clinically significant CDR difference between methods. CDR estimates differed by 0.2 or more in 33.8-48.7% between methods.ConclusionsThe differences in CDR estimates between fundus biomicroscopy and stereoscopic optic disc photo reading showed a wide variation, and reached clinically significance threshold in a large proportion of patients, suggesting a poor agreement. Thus, glaucoma should be monitored by comparing baseline and subsequent CDR estimates using the same method rather than comparing photographs to fundus biomicroscopy.

  4. Fundus autofluorescence in central serous chorioretinopathy:association with spectral-domain optical coherence tomography and fluorescein angiography

    Directory of Open Access Journals (Sweden)

    Peng Zhang

    2015-10-01

    Full Text Available AIM: To evaluate the correlation among changes in fundus autofluorescence (AF measured using infrared fundus AF (IR-AF and short-wave length fundus AF (SW-AF with changes in spectral-domain optical coherence tomography (SD-OCT and fluorescein angiography (FA in central serous chorioretinopathy (CSC.METHODS:Two hundred and twenty consecutive patients with CSC were included. In addition to AF, patients were assessed by means of SD-OCT and FA. Abnormalities in images of IR-AF, SW-AF, FA were analyzed and correlated with the corresponding outer retinal alterations in SD-OCT findings.RESULTS:Eyes with abnormalities on either IR-AF or SW-AF were found in 256 eyes (58.18%, among them 256 eyes (100% showed abnormal IR-AF, but SW-AF abnormalities were present only in 213 eyes (83.20%. The hypo-IR-AF corresponded to accumulation of sub-retinal liquid, collapse of retinal pigment epithelium (RPE or detachment of RPE with or without RPE leakage point in the corresponding area. The hyper-IR-AF corresponded to the area with loss of the ellipsoid portion of the inner segments and sub-sensory retinal deposits or focal melanogenesis under sensory retina. The hypo-SW-AF corresponded to accumulation of sub-retinal liquid or atrophy of RPE. The hyper-SW-AF associated with sub-sensory retinal deposits, detachment of RPE and focal melanogenesis.CONCLUSION:IR-AF was more sensitive than SW-AF and FA for identifying pathological abnormalities in CSC. The characteristics of IR-AF in CSC were attributable to the modification of melanin in the RPE. IR-AF should be used as a common diagnostic tool for identifying pathological lesion in CSC.KEYWORDS:central serous chorioretinopathy; fluorescein angiography; fundus autofluorescence; optical coherence tomography

  5. EVALUATION OF PATCHY ATROPHY SECONDARY TO HIGH MYOPIA BY SEMIAUTOMATED SOFTWARE FOR FUNDUS AUTOFLUORESCENCE ANALYSIS.

    Science.gov (United States)

    Miere, Alexandra; Capuano, Vittorio; Serra, Rita; Jung, Camille; Souied, Eric; Querques, Giuseppe

    2017-05-31

    To evaluate the progression of patchy atrophy in high myopia using semiautomated software for fundus autofluorescence (FAF) analysis. The medical records and multimodal imaging of 21 consecutive highly myopic patients with macular chorioretinal patchy atrophy (PA) were retrospectively analyzed. All patients underwent repeated fundus autofluorescence and spectral domain optical coherence tomography over at least 12 months. Color fundus photography was also performed in a subset of patients. Total atrophy area was measured on FAF images using Region Finder semiautomated software embedded in Spectralis (Heidelberg Engineering, Heidelberg, Germany) at baseline and during follow-up visits. Region Finder was compared with manually measured PA on FAF images. Twenty-two eyes of 21 patients (14 women, 7 men; mean age 62.8 + 13.0 years, range 32-84 years) were included. Mean PA area using Region Finder was 2.77 ± 2.91 SD mm at baseline, 3.12 ± 2.68 mm at Month 6, 3.43 ± 2.68 mm at Month 12, and 3.73 ± 2.74 mm at Month 18 (overall P autofluorescence analysis by Region Finder semiautomated software provides accurate measurements of lesion area and allows us to quantify the progression of PA in high myopia. In our series, PA enlarged significantly over at least 12 months, and its progression seemed to be related to the lesion size at baseline.

  6. Predictors for the progression of geographic atrophy in patients with age-related macular degeneration: fundus autofluorescence study with modified fundus camera.

    Science.gov (United States)

    Jeong, Y J; Hong, I H; Chung, J K; Kim, K L; Kim, H K; Park, S P

    2014-02-01

    We examined the association between abnormal fundus autofluorescence (FAF) features on images obtained by a modified fundus camera (mFC) and geographic atrophy (GA) progression in patients with age-related macular degeneration (AMD). Serial FAF images of 131 eyes from 131 patients with GA were included in the study. All FAF images were obtained with an mFC (excitation, ∼ 500-610 nm; emission, ∼ 675-715 nm). The GA area was quantified at baseline and 1 year later using a customized segmentation program. The yearly GA enlargement rate was then calculated. Abnormal FAF patterns in the junctional zone of GA were classified as None or Minimal change, Focal, Patchy, Banded, or Diffuse according to previously published classification based on confocal scanning laser ophthalmoscopy (cSLO). The relationship between GA enlargement and abnormal FAF was evaluated. The mean rate of GA enlargement was the fastest in eyes with Diffuse pattern (1.74 mm(2) per year), followed by eyes with the Banded pattern (1.69 mm(2) per year). Binary logistic regression analysis revealed that eyes with the Banded and Diffuse pattern had significantly higher risk for GA enlargement compared with eyes with the other patterns. FAF image obtained by mFC appears to be acceptable for evaluating GA in accordance with an established cSLO-based classification. Eyes with the Banded or the Diffuse patterns of abnormal FAF at baseline indicate a high risk for GA progression. Identifying patients at high risk for GA progression using an mFC is broadly available method that can provide additional information to help predict disease course.

  7. Design of a digital PAD based on I/Q demodulation principle

    International Nuclear Information System (INIS)

    Geng Zheqiao; Cui Yanyan; Hou Mi; Pei Guoxi

    2005-01-01

    Conventional analog I/Q demodulator suffers from phase and amplitude imbalance and DC offset, which cause big error into the measurement. A digital PAD is designed. Based on I/Q demodulation principle, using digital algorithms, such as digital filter and Hilbert transform, the conventional measurement error can basically be removed. Measuremental results show that the digital PAD has a maximum phase error of ±0.5 degree and a resolution of 0.2 degree. Its temperature coefficient is -0.1 degree/degree C. Its dynamic ranges for phase-measurement and amplitude-measurement are -1825 dBm and -2020 dBm, respectively. The digital PAD can meet the need of the BEPC II phasing system. (authors)

  8. Fundus autofluorescence in the diagnosis and monitoring of acute retinal necrosis

    OpenAIRE

    Ward, Tyson SJ; Reddy, Ashvini K

    2015-01-01

    Background Acute retinal necrosis (ARN), a vision threatening viral retinitis, is often diagnosed and treated based on clinical findings. These clinical features have been well characterized by various imaging modalities, but not using fundus autofluorescence (FAF), a noninvasive method of evaluating the neurosensory retina and retinal pigment epithelium (RPE) based on the detection of endogenous fluorophores. Findings A patient diagnosed with ARN was followed over a 10-month period to identi...

  9. Contractile profile of esophageal and gastric fundus strips in experimental doxorubicin-induced esophageal atresia

    Directory of Open Access Journals (Sweden)

    F.A. Capeto

    2015-05-01

    Full Text Available Esophageal atresia (EA is characterized by esophageal and gastric motility changes secondary to developmental and postsurgical damage. This study evaluated the in vitro contractile profile of the distal esophagus and gastric fundus in an experimental model of EA induced by doxorubicin (DOXO. Wistar pregnant rats received DOXO 2.2 mg/kg on the 8th and 9th gestational days. On day 21.5, fetuses were collected, sacrificed, and divided into groups: control, DOXO without EA (DOXO-EA, and DOXO with EA (DOXO+EA. Strips from the distal esophagus and gastric fundus were mounted on a wire myograph and isolated organ-bath system, respectively, and subjected to increasing concentrations of carbamylcholine chloride (carbachol, CCh. The isolated esophagus was also stimulated with increasing concentrations of KCl. In esophagus, the concentration-effect curves were reduced in response to CCh in the DOXO+EA and DOXO-EA groups compared to the control group (P0.05. In response to KCl, the distal esophagus samples in the three groups were not statistically different with regard to Emax or EC50 values (P>0.05. No significant difference was noted for EC50 or Emax values in fundic strips stimulated with CCh (P>0.05. In conclusion, exposure of dams to DOXO during gestation inhibited the contractile behavior of esophageal strips from offspring in response to CCh but not KCl, regardless of EA induction. The gastric fundus of DOXO-exposed offspring did not have altered contractile responsiveness to cholinergic stimulation.

  10. Unusual Fundus Autofluorescence Appearance in a Patient with Hydroxychloroquine Retinal Toxicity

    Directory of Open Access Journals (Sweden)

    Sleiman Abou-Ltaif

    2015-06-01

    Full Text Available Purpose: To report an unusual fundus autofluorescence aspect in a patient with suspected hydroxychloroquine retinal toxicity. Method: Case report of an unusual presentation of a patient treated for 9 consecutive years with a therapeutically recommended dose of hydroxychloroquine. Result: We report the case of a 53-year-old Caucasian female treated with 400 mg hydroxychloroquine for rheumatoid arthritis over 9 years, currently on methotrexate and folinic acid, who stopped treatment 3 years ago. The cumulative dose is estimated at 1.314 kg. She recently noticed a reduction of vision in both eyes to 0.34 logMAR, with colour vision problems and major distortion in central vision. Fundus autofluorescence revealed minimal foveal pigmentary changes and more pronounced changes in the retina elsewhere. Foveal changes were confirmed by optical coherence tomography in both eyes. The patient did not report any colour perception difficulties or night vision problems and has no family history of any eye condition. Her visual field tested by an optician was full, with some central changes. Conclusion: Retinal toxicity from hydroxychloroquine can present in a different aspect than the commonly known retinal toxicity, and it happens even after years of cessation of the drug. The role of cumulative dose in toxicity is supported in this paper.

  11. Wide-field fundus autofluorescence corresponds to visual fields in chorioretinitis patients

    Directory of Open Access Journals (Sweden)

    Seidensticker F

    2011-11-01

    Full Text Available Florian Seidensticker1, Aljoscha S Neubauer1, Tamer Wasfy1,2, Carmen Stumpf1, Stephan R Thurau1,*, Anselm Kampik1, Marcus Kernt1,*1Department of Ophthalmology, Ludwig-Maximilians-University, Munich, Germany; 2Department of Ophthalmology, Tanta University, Tanta, Egypt *Both authors contributed equally to this workBackground and objectives: Detection of peripheral fundus autofluorescence (FAF using conventional scanning laser ophthalmoscopes (SLOs is difficult and requires pupil dilation. Here we evaluated the diagnostic properties of wide-field FAF detected by a two-laser wavelength wide-field SLO in uveitis patients.Study design/materials and methods: Observational case series of four patients suffering from different types of posterior uveitis/chorioretinitis. Wide-field FAF images were compared to visual fields. Panretinal FAF was detected by a newly developed SLO, which allows FAF imaging of up to 200° of the retina in one scan without the need for pupil dilation. Visual fields were obtained by Goldmann manual perimetry.Results: Findings from wide-field FAF imaging showed correspondence to visual field defects in all cases.Conclusion: Wide-field FAF allowed the detection of visual field defect-related alterations of the retinal pigment epithelium in all four uveitis cases.Keywords: fundus autofluorescence (FAF, Optomap, wide-field scanning laser ophthalmoscopy, imaging, uveitis, visual field

  12. Application of Optical Coherence Tomography and Contrast Sensitivity Test for Observing Fundus Changes of Patients With Pregnancy-Induced Hypertension Syndrome.

    Science.gov (United States)

    Wang, Zhixue; Zou, Yuanyuan; Li, Wenying; Wang, Xueyan; Zhang, Min; Wang, Wenying

    2015-11-01

    This study was aimed to investigate the fundus changes of patients with pregnancy-induced hypertension syndrome (PIHS) using optical coherence tomography (OCT) technology and contrast sensitivity (CS) tests.Ninety-eight patients with PIHS underwent routine eye examinations including vision correction, fundus examination, OCT, and CS tests. The CS test was performed at low, medium, and high frequency, respectively. Moreover, the difference in CS tests between 2 groups was analyzed by independent-samples T test. The Kruskal-Wallis rank sum test and linear regression model were used to detect the correlation of OCT with CS, respectively. Meanwhile Satterthwaite approximate T test was adopted for pairwise comparisons after nonparametric analysis of variance.The OCT test revealed that 56.76% of the examined eyes showed shallow retinal detachment in the macula lutea and around the optic disk. The differences in CS at each spatial frequency between the case and control group were statistically significant (P tests might be valuable methods in observing fundus changes for PIHS patients.

  13. Automatic Segmentation of Optic Disc in Eye Fundus Images: A Survey

    OpenAIRE

    Allam, Ali; Youssif, Aliaa; Ghalwash, Atef

    2015-01-01

    Optic disc detection and segmentation is one of the key elements for automatic retinal disease screening systems. The aim of this survey paper is to review, categorize and compare the optic disc detection algorithms and methodologies, giving a description of each of them, highlighting their key points and performance measures. Accordingly, this survey firstly overviews the anatomy of the eye fundus showing its main structural components along with their properties and functions. Consequently,...

  14. Dense Fully Convolutional Segmentation of the Optic Disc and Cup in Colour Fundus for Glaucoma Diagnosis

    Directory of Open Access Journals (Sweden)

    Baidaa Al-Bander

    2018-03-01

    Full Text Available Glaucoma is a group of eye diseases which can cause vision loss by damaging the optic nerve. Early glaucoma detection is key to preventing vision loss yet there is a lack of noticeable early symptoms. Colour fundus photography allows the optic disc (OD to be examined to diagnose glaucoma. Typically, this is done by measuring the vertical cup-to-disc ratio (CDR; however, glaucoma is characterised by thinning of the rim asymmetrically in the inferior-superior-temporal-nasal regions in increasing order. Automatic delineation of the OD features has potential to improve glaucoma management by allowing for this asymmetry to be considered in the measurements. Here, we propose a new deep-learning-based method to segment the OD and optic cup (OC. The core of the proposed method is DenseNet with a fully-convolutional network, whose symmetric U-shaped architecture allows pixel-wise classification. The predicted OD and OC boundaries are then used to estimate the CDR on two axes for glaucoma diagnosis. We assess the proposed method’s performance using a large retinal colour fundus dataset, outperforming state-of-the-art segmentation methods. Furthermore, we generalise our method to segment four fundus datasets from different devices without further training, outperforming the state-of-the-art on two and achieving comparable results on the remaining two.

  15. Automatic multiresolution age-related macular degeneration detection from fundus images

    Science.gov (United States)

    Garnier, Mickaël.; Hurtut, Thomas; Ben Tahar, Houssem; Cheriet, Farida

    2014-03-01

    Age-related Macular Degeneration (AMD) is a leading cause of legal blindness. As the disease progress, visual loss occurs rapidly, therefore early diagnosis is required for timely treatment. Automatic, fast and robust screening of this widespread disease should allow an early detection. Most of the automatic diagnosis methods in the literature are based on a complex segmentation of the drusen, targeting a specific symptom of the disease. In this paper, we present a preliminary study for AMD detection from color fundus photographs using a multiresolution texture analysis. We analyze the texture at several scales by using a wavelet decomposition in order to identify all the relevant texture patterns. Textural information is captured using both the sign and magnitude components of the completed model of Local Binary Patterns. An image is finally described with the textural pattern distributions of the wavelet coefficient images obtained at each level of decomposition. We use a Linear Discriminant Analysis for feature dimension reduction, to avoid the curse of dimensionality problem, and image classification. Experiments were conducted on a dataset containing 45 images (23 healthy and 22 diseased) of variable quality and captured by different cameras. Our method achieved a recognition rate of 93:3%, with a specificity of 95:5% and a sensitivity of 91:3%. This approach shows promising results at low costs that in agreement with medical experts as well as robustness to both image quality and fundus camera model.

  16. [Fundus autofluorescence in patients with inherited retinal diseases : Patterns of fluorescence at two different wavelengths.

    NARCIS (Netherlands)

    Theelen, T.; Boon, C.J.F.; Klevering, B.J.; Hoyng, C.B.

    2008-01-01

    BACKGROUND: Fundus autofluorescence (FAF) may be excited and measured at different wavelengths. In the present study we compared short wavelength and near-infrared FAF patterns of retinal dystrophies. METHODS: We analysed both eyes of 108 patients with diverse retinal dystrophies. Besides colour

  17. Investigating the influence of chromatic aberration and optical illumination bandwidth on fundus imaging in rats

    Science.gov (United States)

    Li, Hao; Liu, Wenzhong; Zhang, Hao F.

    2015-10-01

    Rodent models are indispensable in studying various retinal diseases. Noninvasive, high-resolution retinal imaging of rodent models is highly desired for longitudinally investigating the pathogenesis and therapeutic strategies. However, due to severe aberrations, the retinal image quality in rodents can be much worse than that in humans. We numerically and experimentally investigated the influence of chromatic aberration and optical illumination bandwidth on retinal imaging. We confirmed that the rat retinal image quality decreased with increasing illumination bandwidth. We achieved the retinal image resolution of 10 μm using a 19 nm illumination bandwidth centered at 580 nm in a home-built fundus camera. Furthermore, we observed higher chromatic aberration in albino rat eyes than in pigmented rat eyes. This study provides a design guide for high-resolution fundus camera for rodents. Our method is also beneficial to dispersion compensation in multiwavelength retinal imaging applications.

  18. Ageing and digital games

    DEFF Research Database (Denmark)

    Iversen, Sara Mosberg

    Digital games are still to a great degree considered a medium mainly for young boys. However, available statistics on Western media use show that this is far from the case. Increasingly, people of all ages and genders play digital games, also older adults in their early 60s and beyond. The aim...... of the book is to examine, analyse and discuss: 1) What older adults do with digital games and what meanings the use of digital games take on in the everyday life of older adults; 2) How older adults are perceived by society in relation to digital games; 3) How play and games can be used both...

  19. Standard digital reference images for titanium castings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 The digital reference images provided in the adjunct to this standard illustrate various types and degrees of discontinuities occurring in titanium castings. Use of this standard for the specification or grading of castings requires procurement of the adjunct digital reference images, which illustrate the discontinuity types and severity levels. They are intended to provide the following: 1.1.1 A guide enabling recognition of titanium casting discontinuities and their differentiation both as to type and degree through digital radiographic examination. 1.1.2 Example digital radiographic illustrations of discontinuities and a nomenclature for reference in acceptance standards, specifications and drawings. 1.2 The digital reference images consist of seventeen digital files each illustrating eight grades of increasing severity. The files illustrate seven common discontinuity types representing casting sections up to 1-in. (25.4-mm). 1.3 The reference radiographs were developed for casting sections up to 1...

  20. Automatic Drusen Quantification and Risk Assessment of Age-related Macular Degeneration on Color Fundus Images

    NARCIS (Netherlands)

    Grinsven, M.J.J.P. van; Lechanteur, Y.T.E.; Ven, J.P.H. van de; Ginneken, B. van; Hoyng, C.B.; Theelen, T.; Sanchez, C.I.

    2013-01-01

    PURPOSE: To evaluate a machine learning algorithm that allows for computer aided diagnosis (CAD) of non-advanced age-related macular degeneration (AMD) by providing an accurate detection and quantification of drusen location, area and size. METHODS: Color fundus photographs of 407 eyes without AMD

  1. Digital transformation and its effects on the competency framework: a case study of digital banking

    OpenAIRE

    Kreitstshtein, Anton

    2017-01-01

    This thesis is a qualitative study on how the digital transformation affects the firm’s competency framework in the banking sector. The aim of the study is to establish what are the differences between the firms of various degrees of digitalisation, and to use that insight to create a competency framework for a digitally transforming firm. The theoretical framework provides background to the notion of digital transformation and describes the specificities of the digital aspects of the ba...

  2. Digital Discretion

    DEFF Research Database (Denmark)

    Busch, Peter Andre; Zinner Henriksen, Helle

    2018-01-01

    discretion is suggested to reduce this footprint by influencing or replacing their discretionary practices using ICT. What is less researched is whether digital discretion can cause changes in public policy outcomes, and under what conditions such changes can occur. Using the concept of public service values......This study reviews 44 peer-reviewed articles on digital discretion published in the period from 1998 to January 2017. Street-level bureaucrats have traditionally had a wide ability to exercise discretion stirring debate since they can add their personal footprint on public policies. Digital......, we suggest that digital discretion can strengthen ethical and democratic values but weaken professional and relational values. Furthermore, we conclude that contextual factors such as considerations made by policy makers on the macro-level and the degree of professionalization of street...

  3. Modified submucosal tunneling endoscopic resection for submucosal tumors in the esophagus and gastric fundus near the cardia.

    Science.gov (United States)

    Zhang, Qiang; Cai, Jian-Qun; Xiang, Li; Wang, Zhen; de Liu, Si; Bai, Yang

    2017-08-01

    Background and study aims  Submucosal tunneling endoscopic resection with double opening (DO-STER) was developed by our group for the resection of submucosal tumors in the esophagus and gastric fundus near the cardia. This study aimed to provide a preliminary evaluation of feasibility and safety of DO-STER. Methods  The key to DO-STER is the creation of a tunnel opening in the mucosa over the inferior border of the tumor. During resection, the tumor can be gradually pushed out of the submucosal tunnel through the opening, leaving enough space for operation within the tunnel. A total of 10 tumors resected by DO-STER were retrospectively reviewed. Results  All tumors were successfully resected by DO-STER. One tumor was located at the lower esophagus, four at the esophagogastric junction, and five at the gastric fundus near the cardia. Tumor size ranged from 1.0 × 1.2 cm to 3.5 × 5.0 cm, and all tumors originated from the muscularis propria. Operative times ranged from 45 to 150 minutes. No delayed bleeding or perforation occurred. Conclusion DO-STER seems to provide an alternative approach for resection of tumors in the esophagus and gastric fundus near the cardia. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Quantitative Fundus Autofluorescence in Best Vitelliform Macular Dystrophy: RPE Lipofuscin is not Increased in Non-Lesion Areas of Retina.

    Science.gov (United States)

    Sparrow, Janet R; Duncker, Tobias; Woods, Russell; Delori, François C

    2016-01-01

    Since the lipofuscin of retinal pigment epithelial (RPE) cells has been implicated in the pathogenesis of Best vitelliform macular dystrophy, we quantified fundus autofluorescence (quantitative fundus autofluorescence, qAF) as an indirect measure of RPE lipofuscin levels. Mean non-lesion qAF was found to be within normal limits for age. By spectral domain optical coherence tomography (SD-OCT) vitelliform lesions presented as fluid-filled subretinal detachments containing reflective material. We discuss photoreceptor outer segment debris as the source of the intense fluorescence of these lesions and loss of anion channel functioning as an explanation for the bullous photoreceptor-RPE detachment. Unexplained is the propensity of the disease for central retina.

  5. Performing Digital Literature

    Directory of Open Access Journals (Sweden)

    Jerome Fletcher

    2015-11-01

    Full Text Available Digital literature is a complex assemblage of related elements –material, spatial, linguistic, performative, textual, cultural, social– each of which is at one time interdependent and detached. This article discusses the literary creation within the cyberculture from the performativity point of view in relation to the textual apparatus. This is done through the analysis of a selection of performances where physical corporeality has a collaborative function with the body to a greater or lesser degree. Therefore, this physical feature can not only change, but stand at three possible and hybridizable axes: 1 the digital text as protagonist, 2 the digital text as counterpart, and 3 the digital text as site.

  6. Fundus autofluorescence imaging in dry AMD: 2014 Jules Gonin lecture of the Retina Research Foundation.

    Science.gov (United States)

    Holz, Frank G; Steinberg, Julia S; Göbel, Arno; Fleckenstein, Monika; Schmitz-Valckenberg, Steffen

    2015-01-01

    Fundus autofluorescence (FAF) imaging allows for topographic mapping of intrisnic fluorophores in the retinal pigment epithelial cell monolayer, as well as mapping of other fluorophores that may occur with disease in the outer retina and the sub-neurosensory space. FAF imaging provides information not obtainable with other imaging modalities. Near-infrared fundus autofluorescence images can also be obtained in vivo, and may be largely melanin-derived. FAF imaging has been shown to be useful in a wide spectrum of macular and retinal diseases. The scope of applications now includes identification of diseased RPE in macular/retinal diseases, elucidating pathophysiological mechanisms, identification of early disease stages, refined phenotyping, identification of prognostic markers for disease progression, monitoring disease progression in the context of both natural history and interventional therapeutic studies, and objective assessment of luteal pigment distribution and density as well as RPE melanin distribution. Here, we review the use of FAF imaging in various phenotypic manifestations of dry AMD.

  7. Fundus oculi pigmentation studies simulating the fs-LASIK process Fundus oculi pigmentation studies simulating the fs-LASIK process

    Science.gov (United States)

    Sander, M.; Minet, O.; Zabarylo, U.; Müller, M.; Tetz, M. R.

    2012-06-01

    The femtosecond-laser in situ keratomileusis (fs-LASIK) technique has successfully entered the refractive surgery market to correct ametropia by cutting transparent corneal tissue with ultra-short laser pulses based on photodisruption. The laser pulses in the near infrared range (NIR) generate a laser-induced breakdown (LIOB) in the cornea. By propagating through the eye, a certain amount of the pulse is deposited in the cornea and the remaining energy interacts with the strong absorbing tissue behind. Due to the absorption by the retinal pigment epithelium and the transfer of the thermal energy to surrounding tissue, the transmitted energy can induce damage to the retina. The aim of this project was to find out the threshold influences concerning the tissue and the correlation between the results of the macroscopical appraisal and the fundus oculi pigmentation by simulating the fs-LASIK procedure with two various laser systems in the continuous wave (CW) and fs-regime. Therefore ex-vivo determinations were carried out macroscopically and histopathologically on porcine tissue.

  8. Characteristics of Fundus Autofluorescence in Active Polypoidal Choroidal Vasculopathy

    Directory of Open Access Journals (Sweden)

    Zafer Öztaş

    2016-08-01

    Full Text Available Objectives: To define characteristic fundus autofluorescence (FAF findings in eyes with active polypoidal choroidal vasculopathy (PCV. Materials and Methods: Thirty-five eyes of 29 patients with active PCV who were diagnosed at Ege University Faculty of Medicine, Department of Ophthalmology, Retina Division between January 2012 and November 2014 were included in the study. All the patients underwent a complete ophthalmological examination including fundus photography, spectral-domain optical coherence tomography, fluorescein angiography, FAF photography, and indocyanine green angiography (ICGA. ICGA was used to diagnose active PCV and identify lesion components. FAF findings were described at the retinal site of the corresponding lesions identified and diagnosed using ICGA. Results: The mean age of the 29 study patients (15 men, 14 women was 64.6±7.5 years (range, 54-82 years. ICGA revealed active PCV in 35 eyes, consisting of polypoid lesions in 11 eyes (31.4%, branching vascular networks (BVN in 10 eyes (28.6%, and a combination of polypoid lesions and BVNs in 14 eyes (40%. On FAF images, 4 different patterns were detected at the corresponding retinal sites of 25 polypoid lesions detected by ICGA: confluent hypoautofluorescence with a hyperautofluorescent ring in 18 eyes (72%, hyperautofluorescence with hypoautofluorescent ring in 2 eyes (8%, confluent hypoautofluorescence in 1 eye (4%, and granular hypoautofluorescence in 1 eye (4%. The remaining 3 eyes (12% demonstrated blocked hypoautofluorescence because of the excessive hemorrhaging in the macula. The FAF images showed the granular hypoautofluorescent FAF pattern in all 24 BVNs (100% consistent with the location of the lesions on ICGA. Conclusion: The typical PCV lesions, polypoid lesions and BVNs had characteristic autofluorescent findings on FAF imaging. Non-invasive, quick, and repeatable FAF imaging can be considered a reliable and helpful diagnostic technique for the diagnosis of

  9. Fundus Image Features Extraction for Exudate Mining in Coordination with Content Based Image Retrieval: A Study

    Science.gov (United States)

    Gururaj, C.; Jayadevappa, D.; Tunga, Satish

    2018-06-01

    Medical field has seen a phenomenal improvement over the previous years. The invention of computers with appropriate increase in the processing and internet speed has changed the face of the medical technology. However there is still scope for improvement of the technologies in use today. One of the many such technologies of medical aid is the detection of afflictions of the eye. Although a repertoire of research has been accomplished in this field, most of them fail to address how to take the detection forward to a stage where it will be beneficial to the society at large. An automated system that can predict the current medical condition of a patient after taking the fundus image of his eye is yet to see the light of the day. Such a system is explored in this paper by summarizing a number of techniques for fundus image features extraction, predominantly hard exudate mining, coupled with Content Based Image Retrieval to develop an automation tool. The knowledge of the same would bring about worthy changes in the domain of exudates extraction of the eye. This is essential in cases where the patients may not have access to the best of technologies. This paper attempts at a comprehensive summary of the techniques for Content Based Image Retrieval (CBIR) or fundus features image extraction, and few choice methods of both, and an exploration which aims to find ways to combine these two attractive features, and combine them so that it is beneficial to all.

  10. Fully automatic algorithm for the analysis of vessels in the angiographic image of the eye fundus

    Directory of Open Access Journals (Sweden)

    Koprowski Robert

    2012-06-01

    Full Text Available Abstract Background The available scientific literature contains descriptions of manual, semi-automated and automated methods for analysing angiographic images. The presented algorithms segment vessels calculating their tortuosity or number in a given area. We describe a statistical analysis of the inclination of the vessels in the fundus as related to their distance from the center of the optic disc. Methods The paper presents an automated method for analysing vessels which are found in angiographic images of the eye using a Matlab implemented algorithm. It performs filtration and convolution operations with suggested masks. The result is an image containing information on the location of vessels and their inclination angle in relation to the center of the optic disc. This is a new approach to the analysis of vessels whose usefulness has been confirmed in the diagnosis of hypertension. Results The proposed algorithm analyzed and processed the images of the eye fundus using a classifier in the form of decision trees. It enabled the proper classification of healthy patients and those with hypertension. The result is a very good separation of healthy subjects from the hypertensive ones: sensitivity - 83%, specificity - 100%, accuracy - 96%. This confirms a practical usefulness of the proposed method. Conclusions This paper presents an algorithm for the automatic analysis of morphological parameters of the fundus vessels. Such an analysis is performed during fluorescein angiography of the eye. The presented algorithm automatically calculates the global statistical features connected with both tortuosity of vessels and their total area or their number.

  11. Fundus Image Features Extraction for Exudate Mining in Coordination with Content Based Image Retrieval: A Study

    Science.gov (United States)

    Gururaj, C.; Jayadevappa, D.; Tunga, Satish

    2018-02-01

    Medical field has seen a phenomenal improvement over the previous years. The invention of computers with appropriate increase in the processing and internet speed has changed the face of the medical technology. However there is still scope for improvement of the technologies in use today. One of the many such technologies of medical aid is the detection of afflictions of the eye. Although a repertoire of research has been accomplished in this field, most of them fail to address how to take the detection forward to a stage where it will be beneficial to the society at large. An automated system that can predict the current medical condition of a patient after taking the fundus image of his eye is yet to see the light of the day. Such a system is explored in this paper by summarizing a number of techniques for fundus image features extraction, predominantly hard exudate mining, coupled with Content Based Image Retrieval to develop an automation tool. The knowledge of the same would bring about worthy changes in the domain of exudates extraction of the eye. This is essential in cases where the patients may not have access to the best of technologies. This paper attempts at a comprehensive summary of the techniques for Content Based Image Retrieval (CBIR) or fundus features image extraction, and few choice methods of both, and an exploration which aims to find ways to combine these two attractive features, and combine them so that it is beneficial to all.

  12. Clinical research on intravitreal injection of bevacizumab in the treatment of macula lutea and retinal edema of ocular fundus disease.

    Science.gov (United States)

    Yan, Ying; Wang, Tao; Cao, Jing; Wang, Meng; Li, Fenghua

    2015-07-01

    This paper aimed to explore clinically curative effect of intravitreal injection of bevacizumab in the treatment of macula lutea and retinal edema of ocular fundus disease. The number of 300 patients (390 eyes) with ocular fundus diseases including retinal vein occlusion (RVO), diabetic retinopathy (DR), age-related macular degeneration (ARMD), central serous chorioretinopathy (CSC), choridal new vessel (CNV) received and cured in the hospital from February 2010 to February 2014 were given intravitreal injection of bevacizumab (1.5mg) with once per month and a total of 2-3 times. Results of patients' vision and fluorescence fundus angiography (FFA), optical coherence tomography (OCT) before and after treatment were compared and curative effects were evaluated. Vision of 349 eyes (89.49%) improved obviously with the average of more than 2 lines, patient's intraocular pressure (IOP) was normal and all indexes were clearly better; vision of 26 eyes (6.67%) was stable before the treatment and without any changes after the treatment, the situation of fundus got better without increased IOP; vision of 15 eyes (3.85%) decreased to some extent, and the symptoms eased slightly after symptomatic treatment. In the 1st day after intravitreal injection, best-corrected visual acuity increased to 0.239±0.175, best-corrected visual acuity in 1 m was 0.315±0.182, in 3m continuously climbed to 0.350±0.270, and in 6 m was 0.362±0.282. Compared with vision before injection, t value was t=3.184, t=7.213, t=9.274 and t=9.970 (P=0.002, P=0.000, P=0.000 and P=0.000) respectively, and all P were less than 0.01. Furthermore, the difference was significant if a=0.01, which could confirm that 1m best corrected visual acuity of patients after intravitreal injection improved clearly in combination with before injection and 3m and 6 m visions enhanced constantly after injection. To sum up, intravitreal injection of bevacizumab in treating ocular fundus disease improves patient's vision

  13. Automatic non-proliferative diabetic retinopathy screening system based on color fundus image.

    Science.gov (United States)

    Xiao, Zhitao; Zhang, Xinpeng; Geng, Lei; Zhang, Fang; Wu, Jun; Tong, Jun; Ogunbona, Philip O; Shan, Chunyan

    2017-10-26

    Non-proliferative diabetic retinopathy is the early stage of diabetic retinopathy. Automatic detection of non-proliferative diabetic retinopathy is significant for clinical diagnosis, early screening and course progression of patients. This paper introduces the design and implementation of an automatic system for screening non-proliferative diabetic retinopathy based on color fundus images. Firstly, the fundus structures, including blood vessels, optic disc and macula, are extracted and located, respectively. In particular, a new optic disc localization method using parabolic fitting is proposed based on the physiological structure characteristics of optic disc and blood vessels. Then, early lesions, such as microaneurysms, hemorrhages and hard exudates, are detected based on their respective characteristics. An equivalent optical model simulating human eyes is designed based on the anatomical structure of retina. Main structures and early lesions are reconstructed in the 3D space for better visualization. Finally, the severity of each image is evaluated based on the international criteria of diabetic retinopathy. The system has been tested on public databases and images from hospitals. Experimental results demonstrate that the proposed system achieves high accuracy for main structures and early lesions detection. The results of severity classification for non-proliferative diabetic retinopathy are also accurate and suitable. Our system can assist ophthalmologists for clinical diagnosis, automatic screening and course progression of patients.

  14. Crowdsourcing to Evaluate Fundus Photographs for the Presence of Glaucoma.

    Science.gov (United States)

    Wang, Xueyang; Mudie, Lucy I; Baskaran, Mani; Cheng, Ching-Yu; Alward, Wallace L; Friedman, David S; Brady, Christopher J

    2017-06-01

    To assess the accuracy of crowdsourcing for grading optic nerve images for glaucoma using Amazon Mechanical Turk before and after training modules. Images (n=60) from 2 large population studies were graded for glaucoma status and vertical cup-to-disc ratio (VCDR). In the baseline trial, users on Amazon Mechanical Turk (Turkers) graded fundus photos for glaucoma and VCDR after reviewing annotated example images. In 2 additional trials, Turkers viewed a 26-slide PowerPoint training or a 10-minute video training and passed a quiz before being permitted to grade the same 60 images. Each image was graded by 10 unique Turkers in all trials. The mode of Turker grades for each image was compared with an adjudicated expert grade to determine accuracy as well as the sensitivity and specificity of Turker grading. In the baseline study, 50% of the images were graded correctly for glaucoma status and the area under the receiver operating characteristic (AUROC) was 0.75 [95% confidence interval (CI), 0.64-0.87]. Post-PowerPoint training, 66.7% of the images were graded correctly with AUROC of 0.86 (95% CI, 0.78-0.95). Finally, Turker grading accuracy was 63.3% with AUROC of 0.89 (95% CI, 0.83-0.96) after video training. Overall, Turker VCDR grades for each image correlated with expert VCDR grades (Bland-Altman plot mean difference=-0.02). Turkers graded 60 fundus images quickly and at low cost, with grading accuracy, sensitivity, and specificity, all improving with brief training. With effective education, crowdsourcing may be an efficient tool to aid in the identification of glaucomatous changes in retinal images.

  15. Los cinco grados de la comunicación en educación Oral-gestural, writing, audio, audiovisual and… digital? The five degrees of communication in education

    Directory of Open Access Journals (Sweden)

    José María Perceval Verde

    2008-03-01

    Full Text Available En el marco del presente artículo se presenta un recorrido a través de cinco grados de la comunicación en educación: el oral-gestual, la escritura, el audio, el audiovisual y el digital. El texto destaca los cambios que el escenario on-line introduce en el proceso educativo reflexionando sobre la figura del estudiante, del docente y de las relaciones entre ambos. This article portrays an overview of the five degrees of comunication in education: oralgestural, writing, audio, audiovisual and digital. It highlights the changes introduced by the on-line scenario in the educational process, reflecting on the character of the student, the teacher and the relationship between them.

  16. Pengaruh Senam Nifas terhadap Penurunan Tinggi Fundus Uteri pada Ibu Post Partum di RSUP DR. M. Djamil Padang

    Directory of Open Access Journals (Sweden)

    Nurniati Tianastia Rullynil

    2014-09-01

    Full Text Available AbstrakPerdarahan merupakan penyebab utama kesakitan dan kematian ibu pada masa nifas, dimana 50%-60% karena kegagalan miometrium berkontraksi secara sempurna. Salah satu asuhan untuk memaksimalkan kontraksi uterus pada masa nifas adalah dengan melaksanakan senam nifas, guna mempercepat proses involusi uteri. Tujuan penelitian ini adalah untuk mengetahui pengaruh senam nifas terhadap penurunan tinggi fundus uteri (TFU pada ibu post partum. Penelitian ini merupakan studi eksperimental dengan Post Test Only Control Group Design. Alat yang digunakan dalam penelitian berupa kaliper pelvimetri. Diberikan perlakuan senam nifas pada kelompok intervensi dan tidak senam nifas pada kelompok kontrol, kemudian dilakukan pengukuran tinggi fundus uteri hari ke-1, hari ke-3 dan hari ke-6. Data dianalisa menggunakan Uji General Linier Model (GLM. Rerata TFU hari ke-1 pada kelompok intervensi 12,37±0,72 dan 12,42±0,54 pada kelompok kontrol. Rerata TFU hari ke-3 pada kelompok intervensi 9,00±0,94 dan 9,87±0,75 pada kelompok kontrol. Sedangkan rerata TFU hari ke-6 pada kelompok intervensi 5,72±0,88 dan 7,37±0,68 pada kelompok kontrol. Terdapat perbedaan yang signifikan penurunan tinggi fundus uteri antara kedua kelompok pada hari ke-3 (p=0,00 dan hari ke 6 (p=0,00. Dari hasil penelitian dapat disimpulkan bahwa senam nifas berpengaruh terhadap penurunan tinggi fundus uteri. Penurunan tinggi fundus uteri pada kelompok intervensi lebih turun dibanding kelompok kontrol.Kata kunci: senam nifas, tinggi fundus uteri, post partumAbstractHemorrhage is a major cause of maternal morbidity and mortality in the puerperium, about 50%-60% of hemorrhage occurs due to failure of myometrium to contract completely. One care to maximaze uterine contraction during the puerperium is by implementing parturition gymnastics in order to accelarate the process of uterine involution. The purpose of this study was to determine the effect of parturition gymnastics on a decreasing of

  17. Differentiation of ocular fundus fluorophores by fluorescence lifetime imaging using multiple excitation and emission wavelengths

    Science.gov (United States)

    Hammer, M.; Schweitzer, D.; Schenke, S.; Becker, W.; Bergmann, A.

    2006-10-01

    Ocular fundus autofluorescence imaging has been introduced into clinical diagnostics recently. It is in use for the observation of the age pigment lipofuscin, a precursor of age - related macular degeneration (AMD). But other fluorophores may be of interest too: The redox pair FAD - FADH II provides information on the retinal energy metabolism, advanced glycation end products (AGE) indicate protein glycation associated with pathologic processes in diabetes as well as AMD, and alterations in the fluorescence of collagen and elastin in connective tissue give us the opportunity to observe fibrosis by fluorescence imaging. This, however, needs techniques able to differentiate particular fluorophores despite limited permissible ocular exposure as well as excitation wavelength (limited by the transmission of the human ocular lens to >400 nm). We present an ophthalmic laser scanning system (SLO), equipped with picosecond laser diodes (FWHM 100 ps, 446 nm or 468 nm respectively) and time correlated single photon counting (TCSPC) in two emission bands (500 - 560 nm and 560 - 700 nm). The decays were fitted by a bi-exponential model. Fluorescence spectra were measured by a fluorescence spectrometer fluorolog. Upon excitation at 446 nm, the fluorescence of AGE, FAD, and lipofuscin were found to peak at 503 nm, 525 nm, and 600 nm respectively. Accordingly, the statistical distribution of the fluorescence decay times was found to depend on the different excitation wavelengths and emission bands used. The use of multiple excitation and emission wavelengths in conjunction with fluorescence lifetime imaging allows us to discriminate between intrinsic fluorophores of the ocular fundus. Taken together with our knowledge on the anatomical structure of the fundus, these findings suggest an association of the short, middle and long fluorescence decay time to the retinal pigment epithelium, the retina, and connective tissue respectively.

  18. ULTRA-WIDE-FIELD FUNDUS AUTOFLUORESCENCE FINDINGS IN PATIENTS WITH ACUTE ZONAL OCCULT OUTER RETINOPATHY.

    Science.gov (United States)

    Shifera, Amde Selassie; Pennesi, Mark E; Yang, Paul; Lin, Phoebe

    2017-06-01

    To determine whether ultra-wide-field fundus autofluorescence (UWFFAF) findings in acute zonal occult outer retinopathy correlated well with perimetry, optical coherence tomography, and electroretinography findings. Retrospective observational study on 16 eyes of 10 subjects with AZOOR seen at a single referral center from October 2012 to March 2015 who had UWFFAF performed. Chi-square analysis was performed to compare categorical variables, and Mann-Whitney U test used for comparisons of nonparametric continuous variables. All eyes examined within 3 months of symptom onset (five of the five eyes) had diffusely hyperautofluorescent areas on UWFFAF. The remaining eyes contained hypoautofluorescent lesions with hyperautofluorescent borders. In 11/16 (68.8%) eyes, UWFFAF showed the full extent of lesions that would not have been possible with standard fundus autofluorescence centered on the fovea. There were 3 patterns of spread: centrifugal spread (7/16, 43.8%), centripetal spread (5/16, 31.3%), and centrifugal + centripetal spread (4/16, 25.0%). The UWFFAF lesions corresponded well with perimetric, optical coherence tomography, and electroretinography abnormalities. The UWFFAF along with optical coherence tomography can be useful in the evaluation and monitoring of acute zonal occult outer retinopathy patients.

  19. Fundus autofluorescence and optical coherence tomography in the management of progressive outer retinal necrosis

    Science.gov (United States)

    Yeh, Steven; Wong, Wai T.; Weichel, Eric D.; Lew, Julie C.; Chew, Emily Y.; Nussenblatt, Robert B.

    2011-01-01

    A 41 year-old female patient with acquired immune deficiency syndrome (AIDS) presented with progressive nasal visual field loss in her right eye. Ophthalmic exam revealed widespread areas of retinal opacification with hemorrhage consistent with progressive outer retinal necrosis (PORN), which was confirmed by polymerase chain reaction (PCR) for varicella zoster virus (VZV) DNA. The patient was treated with intravenous and intravitreal foscarnet and ganciclovir with a resultant improvement clinically. Optical coherence tomography (OCT) and fundus autofluorescence (FAF) imaging revealed progressive changes indicative of widespread retinal pigment epithelial (RPE) and outer retinal dysfunction. OCT was useful in documenting progressive changes in macular architecture during therapy including neurosensory elevation, cystoid macular edema, and severe outer retinal necrosis, at initial exam, 1 week, and 1 month follow-up. Fundus autofluorescence revealed areas of stippled, hyperfluorescence within extensive zones of hypofluorescence, which progressed during the follow-up period. These areas appeared to represent lipofuscin or its photoreactive components within larger regions of RPE loss. The combination of OCT and FAF was useful in the characterization of the RPE and retinal anatomy in this patient with PORN. PMID:20337261

  20. Centrifugal Expansion of Fundus Autofluorescence Patterns in Stargardt Disease Over Time

    Science.gov (United States)

    Cukras, Catherine A.; Wong, Wai T.; Caruso, Rafael; Cunningham, Denise; Zein, Wadih; Sieving, Paul

    2012-01-01

    Objective Changing lipofuscin and melanin content in RPE cells has been hypothesized to contribute to Stargardt disease pathogenesis. Longitudinal study of autofluorescence in Stargardt disease which reflect changing fluorophore compositions can reveal aspects of disease progression not previously evident. Method We examined the temporal-spatial patterns of fundus autofluorescence with excitation at both 488 nm (standard fundus autofluorescence, FAF) and 795nm (near infrared autofluorescence, NIA) in a longitudinal case series involving 8 eyes of 4 patients (range of follow-up = 11 to 57 months; mean = 39 months). Image processing was performed to analyze spatial and temporal cross-modality associations. Results Longitudinal FAF imaging of fleck lesions revealed hyperautofluorescent lesions that extended in a centrifugal direction from the fovea with time. Patterns of spread were non-random and followed a radial path that leaves behind a trail of diminishing autofluorescence. Longitudinal NIA imaging also demonstrated centrifugal lesion spread, but with fewer hyperautofluorescent lesions, suggestive of more transient hyperautofluorescence and more rapid decay at longer wavelengths. FAF and NIA abnormalities were spatially correlated to each other, and together reflect systematic progressions in fleck distribution and fluorophore composition occurring during the natural history of the disease. Conclusion Stargardt disease fleck lesions do not evolve randomly in location but instead follow consistent patterns of radial expansion and a systematic decay of autofluorescence that reflect changing lipofuscin and melanin compositions in RPE cells. These progressive foveal-to-peripheral changes are helpful in elucidating molecular and cellular mechanisms underlying Stargardt disease and may constitute potential outcome measures in clinical trials. PMID:21987580

  1. Automatic classification of pathological myopia in retinal fundus images using PAMELA

    Science.gov (United States)

    Liu, Jiang; Wong, Damon W. K.; Tan, Ngan Meng; Zhang, Zhuo; Lu, Shijian; Lim, Joo Hwee; Li, Huiqi; Saw, Seang Mei; Tong, Louis; Wong, Tien Yin

    2010-03-01

    Pathological myopia is the seventh leading cause of blindness. We introduce a framework based on PAMELA (PAthological Myopia dEtection through peripapilLary Atrophy) for the detection of pathological myopia from fundus images. The framework consists of a pre-processing stage which extracts a region of interest centered on the optic disc. Subsequently, three analysis modules focus on detecting specific visual indicators. The optic disc tilt ratio module gives a measure of the axial elongation of the eye through inference from the deformation of the optic disc. In the texturebased ROI assessment module, contextual knowledge is used to demarcate the ROI into four distinct, clinically-relevant zones in which information from an entropy transform of the ROI is analyzed and metrics generated. In particular, the preferential appearance of peripapillary atrophy (PPA) in the temporal zone compared to the nasal zone is utilized by calculating ratios of the metrics. The PPA detection module obtains an outer boundary through a level-set method, and subtracts this region against the optic disc boundary. Temporal and nasal zones are obtained from the remnants to generate associated hue and color values. The outputs of the three modules are used as in a SVM model to determine the presence of pathological myopia in a retinal fundus image. Using images from the Singapore Eye Research Institute, the proposed framework reported an optimized accuracy of 90% and a sensitivity and specificity of 0.85 and 0.95 respectively, indicating promise for the use of the proposed system as a screening tool for pathological myopia.

  2. The significance of fluorescein angiography in the early diagnosis of lesions on ocular fundus at pseudoxanthoma elasticum patients.

    Science.gov (United States)

    Bogdanowski, T; Gluza, J; Rasiewicz, D

    1977-05-27

    The role of fluorescein angiography in early diagnosis of lesions on fundus of the eye at pseudoxanthoma elasticum patients has been shown. The authors show angiographic changes on the basis of three cases of pseudoxanthoma elasticum patients.

  3. Color Fundus Photography, Optical Coherence Tomography, and Fluorescein Angiography in Diagnosing Polypoidal Choroidal Vasculopathy.

    Science.gov (United States)

    Chaikitmongkol, Voraporn; Khunsongkiet, Preeyanuch; Patikulsila, Direk; Ratanasukon, Mansing; Watanachai, Nawat; Jumroendararasame, Chaisiri; Mayerle, Catherine B; Han, Ian C; Chen, Connie J; Winaikosol, Pawara; Dejkriengkraikul, Chutikarn; Choovuthayakorn, Janejit; Kunavisarut, Paradee; Bressler, Neil M

    2018-05-10

    To determine sensitivity and specificity of polypoidal choroidal vasculopathy (PCV) diagnosis using color fundus photography (CFP), optical coherence tomography (OCT) and fundus fluorescein angiography (FFA) without indocyanine-green angiography (ICGA). Validity analysis. Treatment-naïve eyes with serous/serosanguinous maculopathy undergoing CFP, OCT, FFA and ICGA imaging before treatment at a university-hospital in Thailand (January 2013 to June 2015) were identified. Images of each subject were categorized into 4 sets (set A: CFP; set B: CFP+OCT; set C: CFP+FFA; set D: CFP+OCT+FFA). Six graders, 3 from Thailand (PCV endemic area) and 3 from U.S. (non-endemic area), individually reviewed each set (without ICG), and determined if the presumed diagnosis was PCV. In parallel, 2 other graders confirmed if each case had PCV or not using EVEREST criteria (including ICGA). Sensitivity and specificity of a PCV diagnosis with each set (without ICGA) were analyzed compared with diagnoses including ICGA. Of 119 study eyes (113 subjects, 57% male, mean age±SD 59.9±13.8), definite PCV diagnosis was 40.3%. Sensitivity of sets A, B, C, D: 0.63 (95%CI: 0.47-0.76), 0.83 (95%CI: 0.69-0.92), 0.54 (95%CI: 0.39-0.68), 0.67 (95%CI: 0.51-0.79). Specificity were 0.93 (95% CI: 0.84-0.97), 0.83 (95%CI: 0.72-0.91), 0.97 (95%CI: 0.89-0.99), 0.92 (95%CI: 0.82-0.97). Accuracies: 0.81 (95%CI: 0.73-0.88), 0.83 (95%CI: 0.76-0.90), 0.79 (95%CI: 0.73-0.87), 0.82 (95%CI: 0.74-0.88). Discrepancies between Thai and US graders existed through sets A, C, and D. These data suggest without ICGA, fundus photography combined with OCT provides high sensitivity and high specificity to diagnosis PCV; adding FFA does not improve accuracy. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Nerve canals at the fundus of the internal auditory canal on high-resolution temporal bone CT

    International Nuclear Information System (INIS)

    Ji, Yoon Ha; Youn, Eun Kyung; Kim, Seung Chul

    2001-01-01

    To identify and evaluate the normal anatomy of nerve canals in the fundus of the internal auditory canal which can be visualized on high-resolution temporal bone CT. We retrospectively reviewed high-resolution (1 mm thickness and interval contiguous scan) temporal bone CT images of 253 ears in 150 patients who had not suffered trauma or undergone surgery. Those with a history of uncomplicated inflammatory disease were included, but those with symptoms of vertigo, sensorineural hearing loss, or facial nerve palsy were excluded. Three radiologists determined the detectability and location of canals for the labyrinthine segment of the facial, superior vestibular and cochlear nerve, and the saccular branch and posterior ampullary nerve of the inferior vestibular nerve. Five bony canals in the fundus of the internal auditory canal were identified as nerve canals. Four canals were identified on axial CT images in 100% of cases; the so-called singular canal was identified in only 68%. On coronal CT images, canals for the labyrinthine segment of the facial and superior vestibular nerve were seen in 100% of cases, but those for the cochlear nerve, the saccular branch of the inferior vestibular nerve, and the singular canal were seen in 90.1%, 87.4% and 78% of cases, respectiveIy. In all detectable cases, the canal for the labyrinthine segment of the facial nerve was revealed as one which traversed anterolateralIy, from the anterosuperior portion of the fundus of the internal auditory canal. The canal for the cochlear nerve was located just below that for the labyrinthine segment of the facial nerve, while that canal for the superior vestibular nerve was seen at the posterior aspect of these two canals. The canal for the saccular branch of the inferior vestibular nerve was located just below the canal for the superior vestibular nerve, and that for the posterior ampullary nerve, the so-called singular canal, ran laterally or posteolateralIy from the posteroinferior aspect of

  5. Nerve canals at the fundus of the internal auditory canal on high-resolution temporal bone CT

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Yoon Ha; Youn, Eun Kyung; Kim, Seung Chul [Sungkyunkwan Univ., School of Medicine, Seoul (Korea, Republic of)

    2001-12-01

    To identify and evaluate the normal anatomy of nerve canals in the fundus of the internal auditory canal which can be visualized on high-resolution temporal bone CT. We retrospectively reviewed high-resolution (1 mm thickness and interval contiguous scan) temporal bone CT images of 253 ears in 150 patients who had not suffered trauma or undergone surgery. Those with a history of uncomplicated inflammatory disease were included, but those with symptoms of vertigo, sensorineural hearing loss, or facial nerve palsy were excluded. Three radiologists determined the detectability and location of canals for the labyrinthine segment of the facial, superior vestibular and cochlear nerve, and the saccular branch and posterior ampullary nerve of the inferior vestibular nerve. Five bony canals in the fundus of the internal auditory canal were identified as nerve canals. Four canals were identified on axial CT images in 100% of cases; the so-called singular canal was identified in only 68%. On coronal CT images, canals for the labyrinthine segment of the facial and superior vestibular nerve were seen in 100% of cases, but those for the cochlear nerve, the saccular branch of the inferior vestibular nerve, and the singular canal were seen in 90.1%, 87.4% and 78% of cases, respectiveIy. In all detectable cases, the canal for the labyrinthine segment of the facial nerve was revealed as one which traversed anterolateralIy, from the anterosuperior portion of the fundus of the internal auditory canal. The canal for the cochlear nerve was located just below that for the labyrinthine segment of the facial nerve, while that canal for the superior vestibular nerve was seen at the posterior aspect of these two canals. The canal for the saccular branch of the inferior vestibular nerve was located just below the canal for the superior vestibular nerve, and that for the posterior ampullary nerve, the so-called singular canal, ran laterally or posteolateralIy from the posteroinferior aspect of

  6. Agreement in Measurement of Optic Cup-to-Disc Ratio with Stereo Biomicroscope Funduscopy and Digital Image Analysis: Results from the Nigeria National Blindness and Visual Impairment Survey.

    Science.gov (United States)

    Kyari, Fatima; Gilbert, Clare

    2017-02-01

    To determine agreement in estimations of vertical cup-to-disc ratio (VCDR) between clinical stereo-biomicroscopic funduscopy and digital fundus image analysis. Systematic sampling of 1-in-7 from a sample of 13,591 participants aged ≥40 years gave a subsample who were examined in detail. VCDR was estimated clinically by 60 diopter aspheric lens biomicroscopic funduscopy (c-VCDR) and by digital fundus images (i-VCDR) graded at the Moorfields Eye Hospital Reading Centre. Spearman's correlation coefficient, paired t-test and the Bland-Altman method to assess limits of agreement (LOA) between the two methods were applied. Of 1759 participants in the subsample, 848 participants (48%) with normal frequency doubling technology (FDT) visual fields and data for i-VCDR and c-VCDR in both eyes (n = 1696 eyes) were included in the analysis. By absolute difference of VCDR values for each eye between the two methods, 1585 eyes (94%) differed by ≤0.2. Mean i-VCDR was 0.381 (standard deviation, SD 0.156), and mean c-VCDR 0.321 (SD 0.145). i-VCDRs were significantly larger by a mean difference of 0.061 (SD 0.121; 95% confidence interval, CI, 0.055-0.066; p method were lower limit -0.182 (95% CI -0.192 to -0.172) and upper limit 0.303 (95% CI 0.293-0.313). The 95% LOA intervals narrowed with higher VCDR. Digital image analysis and clinical assessment are two distinct methods to measure VCDR; with larger i-VCDRs in this survey. Applying i-VCDR cut-off values to c-VCDR measurements in the Nigeria Blindness Survey might have underestimated glaucoma prevalence. It is recommended that all participants in glaucoma surveys have VCDR by digital image measurement.

  7. Agreement between clinical estimation and a new quantitative analysis by Photoshop software in fundus and angiographic image variables.

    Science.gov (United States)

    Ramezani, Alireza; Ahmadieh, Hamid; Azarmina, Mohsen; Soheilian, Masoud; Dehghan, Mohammad H; Mohebbi, Mohammad R

    2009-12-01

    To evaluate the validity of a new method for the quantitative analysis of fundus or angiographic images using Photoshop 7.0 (Adobe, USA) software by comparing with clinical evaluation. Four hundred and eighteen fundus and angiographic images of diabetic patients were evaluated by three retina specialists and then by computing using Photoshop 7.0 software. Four variables were selected for comparison: amount of hard exudates (HE) on color pictures, amount of HE on red-free pictures, severity of leakage, and the size of the foveal avascular zone (FAZ). The coefficient of agreement (Kappa) between the two methods in the amount of HE on color and red-free photographs were 85% (0.69) and 79% (0.59), respectively. The agreement for severity of leakage was 72% (0.46). In the two methods for the evaluation of the FAZ size using the magic and lasso software tools, the agreement was 54% (0.09) and 89% (0.77), respectively. Agreement in the estimation of the FAZ size by the lasso magnetic tool was excellent and was almost as good in the quantification of HE on color and on red-free images. Considering the agreement of this new technique for the measurement of variables in fundus images using Photoshop software with the clinical evaluation, this method seems to have sufficient validity to be used for the quantitative analysis of HE, leakage, and FAZ size on the angiograms of diabetic patients.

  8. Retinal pigment epithelial changes in chronic Vogt-Koyanagi-Harada disease: fundus autofluorescence and spectral domain optical coherence tomography findings

    Science.gov (United States)

    Vasconcelos-Santos, Daniel V.; Sohn, Elliott H.; Sadda, Srinivas; Rao, Narsing A.

    2009-01-01

    Purpose To determine whether fundus autofluorescence (FAF) and spectral-domain optical coherence tomography (SD-OCT) imaging allows better assessment of RPE and outer retina (OR) in subjects with chronic VKH compared to examination and angiography alone. Methods Cross-sectional analysis of a series of seven consecutive patients with chronic VKH undergoing FAF and SD-OCT. Chronic VKH was defined as during >3 months. Color fundus photographs were correlated to FAF and SD-OCT images. The images were later correlated to fluorescein angiography (FA) and indocyanine green angiography (ICG-A). Results All patients had sunset glow fundus, which resulted in no apparent corresponding abnormality on FAF or SD-OCT. Lesions with decreased autofluorescence signal were observed in 11 eyes (85%), being associated with loss of the RPE and involvement of OR on SD-OCT. In 5 eyes (38%) some of these lesions were very subtle on clinical examination but easily detected by FAF. Lesions with increased autofluorescence signal were seen in 8 eyes (61.5%), showing variable involvement of the OR on SD-OCT and corresponding clinically to areas of RPE proliferation and cystoid macular edema. Conclusion Combined use of FAF and SD-OCT imaging allowed noninvasive delineation of RPE/OR changes in patients with chronic VKH, which were consistent with previous histopathological reports. Some of these changes were not apparent on clinical examination. PMID:20010321

  9. The Nonmydriatic Fundus Camera in Diabetic Retinopathy Screening: A Cost-Effective Study with Evaluation for Future Large-Scale Application

    Directory of Open Access Journals (Sweden)

    Giuseppe Scarpa

    2016-01-01

    Full Text Available Aims. The study aimed to present the experience of a screening programme for early detection of diabetic retinopathy (DR using a nonmydriatic fundus camera, evaluating the feasibility in terms of validity, resources absorption, and future advantages of a potential application, in an Italian local health authority. Methods. Diabetic patients living in the town of Ponzano, Veneto Region (Northern Italy, were invited to be enrolled in the screening programme. The “no prevention strategy” with the inclusion of the estimation of blindness related costs was compared with screening costs in order to evaluate a future extensive and feasible implementation of the procedure, through a budget impact approach. Results. Out of 498 diabetic patients eligible, 80% was enrolled in the screening programme. 115 patients (34% were referred to an ophthalmologist and 9 cases required prompt treatment for either proliferative DR or macular edema. Based on the pilot data, it emerged that an extensive use of the investigated screening programme, within the Greater Treviso area, could prevent 6 cases of blindness every year, resulting in a saving of €271,543.32 (−13.71%. Conclusions. Fundus images obtained with a nonmydriatic fundus camera could be considered an effective, cost-sparing, and feasible screening tool for the early detection of DR, preventing blindness as a result of diabetes.

  10. EARLY SIMULTANEOUS FUNDUS AUTOFLUORESCENCE AND OPTICAL COHERENCE TOMOGRAPHY FEATURES AFTER PARS PLANA VITRECTOMY FOR PRIMARY RHEGMATOGENOUS RETINAL DETACHMENT

    NARCIS (Netherlands)

    Dellʼomo, Roberto; Mura, Marco; Lesnik Oberstein, Sarit Y.; Bijl, Heico; Tan, H. Stevie

    2012-01-01

    Purpose: To describe fundus autofluorescence and optical coherence tomography (OCT) features of the macula after pars plana vitrectomy for rhegmatogenous retinal detachment. Methods: Thirty-three eyes of 33 consecutive patients with repaired rhegmatogenous retinal detachment with or without the

  11. Fundus Autofluorescence Captured With a Nonmydriatic Retinal Camera in Vegetarians Versus Nonvegetarians.

    Science.gov (United States)

    Kommana, Sumana S; Padgaonkar, Pooja; Mendez, Nicole; Wu, Lesley; Szirth, Bernard; Khouri, Albert S

    2015-09-09

    A baseline level of lipofuscin in the retinal pigment epithelium (RPE) is inevitable with age, but increased levels due to increased oxidative stress can result in deleterious vision loss at older ages. As earlier detection of differences in levels can lead to superior preventative management, we studied the relationship between lipofuscin accumulation and dietary lifestyle (vegetarian vs. nonvegetarian) in the younger, healthy South Asian population using retinal fundus autofluorescence (FAF) imaging. In this pilot study, we examined 37 healthy subjects (average age 23 years ± 1) all undergoing similar stress levels as medical students at Rutgers New Jersey Medical School. Levels of lipofuscin concentrations were imaged using a FAF retinal camera (Canon CX-1). Two images (color and FAF) were captured of the left eye and included in the analysis. FAF quantitative scoring was measured in 2 regions of the captured image, the papillo-macular region (P) and the macula (M), by determining the grayscale score of a 35.5 mm(2) rectangle in the respective regions. Standardized scores (corrected to remove baseline fluorescence) were then obtained. Means, standard deviations, and t tests were performed for comparisons. Fundus autofluorescence scores of regions P and M were significantly different (P vegetarians had statistically significant lower levels of autofluorescence. These findings can have potential implications regarding long-term retinal health and risk for developing certain diseases over decades in subjects at risk for vision-threatening diseases. © 2015 Diabetes Technology Society.

  12. Statistical characterization and segmentation of drusen in fundus images.

    Science.gov (United States)

    Santos-Villalobos, H; Karnowski, T P; Aykac, D; Giancardo, L; Li, Y; Nichols, T; Tobin, K W; Chaum, E

    2011-01-01

    Age related Macular Degeneration (AMD) is a disease of the retina associated with aging. AMD progression in patients is characterized by drusen, pigmentation changes, and geographic atrophy, which can be seen using fundus imagery. The level of AMD is characterized by standard scaling methods, which can be somewhat subjective in practice. In this work we propose a statistical image processing approach to segment drusen with the ultimate goal of characterizing the AMD progression in a data set of longitudinal images. The method characterizes retinal structures with a statistical model of the colors in the retina image. When comparing the segmentation results of the method between longitudinal images with known AMD progression and those without, the method detects progression in our longitudinal data set with an area under the receiver operating characteristics curve of 0.99.

  13. Statistical Characterization and Segmentation of Drusen in Fundus Images

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Villalobos, Hector J [ORNL; Karnowski, Thomas Paul [ORNL; Aykac, Deniz [ORNL; Giancardo, Luca [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK); Nichols, Trent L [ORNL; Tobin Jr, Kenneth William [ORNL; Chaum, Edward [University of Tennessee, Knoxville (UTK)

    2011-01-01

    Age related Macular Degeneration (AMD) is a disease of the retina associated with aging. AMD progression in patients is characterized by drusen, pigmentation changes, and geographic atrophy, which can be seen using fundus imagery. The level of AMD is characterized by standard scaling methods, which can be somewhat subjective in practice. In this work we propose a statistical image processing approach to segment drusen with the ultimate goal of characterizing the AMD progression in a data set of longitudinal images. The method characterizes retinal structures with a statistical model of the colors in the retina image. When comparing the segmentation results of the method between longitudinal images with known AMD progression and those without, the method detects progression in our longitudinal data set with an area under the receiver operating characteristics curve of 0.99.

  14. Diabetic retinal pigment epitheliopathy: fundus autofluorescence and spectral-domain optical coherence tomography findings.

    Science.gov (United States)

    Kang, Eui Chun; Seo, Yuri; Byeon, Suk Ho

    2016-10-01

    To describe the characteristics of an unfamiliar disease entity, diabetic retinal pigment epitheliopathy (DRPE), using fundus autofluorescence (FAF) and spectral-domain optical coherence tomography (SD-OCT). This retrospective study included 17 eyes from 10 proliferative diabetic retinopathy (PDR) patients with granular hypo-autofluorescence and/or variable hyper-autofluorescence on FAF (DRPE group) and 17 eyes from 10 age- and sex-matched PDR patients without abnormal autofluorescence (PDR group). Eyes with diabetic macular edema were excluded. Visual acuity (VA), retinal thickness (RT), and choroidal thickness (CT) were compared between the groups. Eyes in the DRPE group had worse logMAR VA than eyes in the PDR group (0.369 ± 0.266 vs. 0.185 ± 0.119; P = 0.026). The thickness of the retinal pigment epithelium plus the inner segment/outer segment of the photoreceptors was reduced to a greater degree in the DRPE group than the PDR group (P retina showed no differences between the two groups. CT was significantly thicker in the DRPE group than in the PDR group (329.00 ± 33.76 vs. 225.62 ± 37.47 μm; P retina, and thicker choroid in comparison with eyes with PDR. Alterations of autofluorescence on FAF and changes in the outer retinal thickness and CT on SD-OCT can be helpful for differentiating DRPE in patients with PDR.

  15. [Fundus autofluorescence. Has it a place in the management of diabetic macular edema?

    Science.gov (United States)

    Zbiba, W; Baba, A; Bouayed, E; Daldoul, A

    2016-11-01

    Analyze the characteristics of fundus autofluorescence of diabetic macular edema and study the association between these characteristics and visual function. Our study included 18 patients (28 eyes) with clinically significant diabetic macular edema. All patients had a complete eye examination with a fundus autofluorescence imaging and optical coherence tomography. The central macular thickness and central macular volume were measured. The integrity of the inner segment-outer segment junction and the integrity of the external limiting membrane were also evaluated in the same area. Among the 28 eyes studied, 8 had normal autofluorescence. The remaining 20 eyes had abnormal autofluorescence: a hyper-cystoid autofluorescence in 5 eyes (25%), hyper-spot autofluorescence in 8 eyes (40%), and hypo-irregular autofluorescence in 5 eyes (25%). Best corrected visual acuity was significantly better in patients with normal autofluorescence and those with hyper-cystoid autofluorescence. There was no significant difference in central macular thickness (P=0.186) and central macular volume (P=0.191) between the four groups. The autofluorescence is a simple, fast, and non-invasive technique for the study of diabetic macular edema with good correlation to the visual function as well as to the extent of damage to the retina. It is, therefore, a possible alternative to other invasive imaging techniques in particular in the long term monitoring of diabetic macular edema. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  16. Detection of Blood Vessels in Color Fundus Images using a Local Radon Transform

    Directory of Open Access Journals (Sweden)

    Reza Pourreza

    2010-09-01

    Full Text Available Introduction: This paper addresses a method for automatic detection of blood vessels in color fundus images which utilizes two main tools: image partitioning and local Radon transform. Material and Methods: The input images are firstly divided into overlapping windows and then the Radon transform is applied to each. The maximum of the Radon transform in each window corresponds to the probable available sub-vessel. To verify the detected sub-vessel, the maximum is compared with a predefined threshold. The verified sub-vessels are reconstructed using the Radon transform information. All detected and reconstructed sub-vessels are finally combined to make the final vessel tree. Results: The algorithm’s performance was evaluated numerically by applying it to 40 images of DRIVE database, a standard retinal image database. The vessels were extracted manually by two physicians. This database was used to test and compare the available and proposed algorithms for vessel detection in color fundus images. By comparing the output of the algorithm with the manual results, the two parameters TPR and FPR were calculated for each image and the average of TPRs and FPRs were used to plot the ROC curve. Discussion and Conclusion: Comparison of the ROC curve of this algorithm with other algorithms demonstrated the high achieved accuracy. Beside the high accuracy, the Radon transform which is integral-based makes the algorithm robust against noise.

  17. A gene for late-onset fundus flavimaculatus with macular dystrophy maps to chromosome 1p13

    Energy Technology Data Exchange (ETDEWEB)

    Gerber, S.; Rozet, J.M.; Bonneau, D.; Souied, E.; Camuzat, A.; Munnich, A.; Kaplan, J. [Hopital des Enfants Malades, Paris (France); Dufier, J.L. [Hopital Laeennec, Paris (France); Amalric, P. [Consultation d`Ophtalmologie, Albi (France); Weissenbach, J. [Genethon, Evry (France)

    1995-02-01

    Fundus flavimaculatus with macular dystrophy is an autosomal recessive disease responsible for a progressive loss of visual acuity in adulthood, with pigmentary changes of the macula, perimacular flecks, and atrophy of the retinal pigmentary epithelium. Since this condition shares several clinical features with Stargardt disease, which has been mapped to chromosome 1p21-p13, we tested the disease for linkage to chromosome 1p. We report the mapping of the disease locus to chromosome 1p13-p21, in the genetic interval defined by loci D1S435 and D1S415, in four multiplex families (maximum lod score 4.79 at recombination fraction 0 for probe AFM217xb2 at locus D1S435). Thus, despite differences in the age at onset, clinical course, and severity, fundus flavimaculatus with macular dystrophy and Stargardt disease are probably allelic disorders. This result supports the view that allelic mutations produce a continuum of macular dystrophies, with onset in early childhood to late adulthood. 16 refs., 3 figs., 1 tab.

  18. Modification of a Kowa RC-2 fundus camera for self-photography without the use of mydriatics. [for blood vessel monitoring during space flight

    Science.gov (United States)

    Philpott, D. E.; Harrison, G.; Turnbill, C.; Bailey, P. F.

    1979-01-01

    Research on retinal circulation during space flight required the development of a simple technique to provide self monitoring of blood vessel changes in the fundus without the use of mydriatics. A Kowa RC-2 fundus camera was modified for self-photography by the use of a bite plate for positioning and cross hairs for focusing the subject's retina relative to the film plane. Dilation of the pupils without the use of mydriatics was accomplished by dark-adaption of the subject. Pictures were obtained without pupil constriction by the use of a high speed strobe light. This method also has applications for clinical medicine.

  19. Multispectral imaging of the ocular fundus using light emitting diode illumination.

    Science.gov (United States)

    Everdell, N L; Styles, I B; Calcagni, A; Gibson, J; Hebden, J; Claridge, E

    2010-09-01

    We present an imaging system based on light emitting diode (LED) illumination that produces multispectral optical images of the human ocular fundus. It uses a conventional fundus camera equipped with a high power LED light source and a highly sensitive electron-multiplying charge coupled device camera. It is able to take pictures at a series of wavelengths in rapid succession at short exposure times, thereby eliminating the image shift introduced by natural eye movements (saccades). In contrast with snapshot systems the images retain full spatial resolution. The system is not suitable for applications where the full spectral resolution is required as it uses discrete wavebands for illumination. This is not a problem in retinal imaging where the use of selected wavelengths is common. The modular nature of the light source allows new wavelengths to be introduced easily and at low cost. The use of wavelength-specific LEDs as a source is preferable to white light illumination and subsequent filtering of the remitted light as it minimizes the total light exposure of the subject. The system is controlled via a graphical user interface that enables flexible control of intensity, duration, and sequencing of sources in synchrony with the camera. Our initial experiments indicate that the system can acquire multispectral image sequences of the human retina at exposure times of 0.05 s in the range of 500-620 nm with mean signal to noise ratio of 17 dB (min 11, std 4.5), making it suitable for quantitative analysis with application to the diagnosis and screening of eye diseases such as diabetic retinopathy and age-related macular degeneration.

  20. Exploration of operator method digital optical computers for application to NASA

    Science.gov (United States)

    1990-01-01

    Digital optical computer design has been focused primarily towards parallel (single point-to-point interconnection) implementation. This architecture is compared to currently developing VHSIC systems. Using demonstrated multichannel acousto-optic devices, a figure of merit can be formulated. The focus is on a figure of merit termed Gate Interconnect Bandwidth Product (GIBP). Conventional parallel optical digital computer architecture demonstrates only marginal competitiveness at best when compared to projected semiconductor implements. Global, analog global, quasi-digital, and full digital interconnects are briefly examined as alternative to parallel digital computer architecture. Digital optical computing is becoming a very tough competitor to semiconductor technology since it can support a very high degree of three dimensional interconnect density and high degrees of Fan-In without capacitive loading effects at very low power consumption levels.

  1. Successful replantation in ten-digit amputation.

    Science.gov (United States)

    Kantarci, Umit; Cepel, Selim; Buldu, Halil

    2010-01-01

    Amputations involving ten digits are very rare because of different lengths of the digits. A 34-year-old man working in a printing house presented one hour after guillotine amputation involving all ten digits. Surgery was initiated 80 minutes after admission and took seven hours. Under axillary anesthesia, the operation was performed by two teams each consisting of two microsurgeons and two assistants. Replantation was completed without the use of any skin graft or flap. Fingertip examination showed poor arterial circulation in the second, third, and fourth digits of the left hand after 24 hours of replantation and surgical exploration was performed, during which anastomosis of the ulnar digital artery of the second digit was re-established and a Y-shaped vein graft was placed at the level of the third web to restore revascularization of the third and fourth digits. However, these interventions did not prevent the development of necrosis in the distal segment of the fourth digit which resulted in dry gangrene that required amputation. After 38 months of replantation, radiographic examination showed complete union in all fingers without malunion or damage to the joint surface and about 8 degrees of medial angulation in the proximal phalanx of the fourth digit of the right hand. The patient did not have difficulty in performing daily activities and had a considerably good pinching. Losses of active range of motion of the metacarpophalangeal and interphalangeal joints were within the rage of 10 to 30 degrees in both hands. In the assessment of sensation, static and dynamic two-point discrimination test results were 6.1 mm and 4.0 mm, respectively.

  2. Digital Citizenship in K-12: It Takes a Village

    Science.gov (United States)

    Hollandsworth, Randy; Dowdy, Lena; Donovan, Judy

    2011-01-01

    Digital citizenship encompasses a wide range of behaviors with varying degrees of risk and possible negative consequences. Lack of digital citizenship awareness and education can, and has, led to problematic, even dangerous student conduct. If our educational village does not address these issues, the digital culture establishes its own direction,…

  3. Rancang Bangun Alat Ukur Unting-unting Digital dan Waterpass Digital dengan Accelero Sensor Berbasis Mikrokontroler ATmega8

    Directory of Open Access Journals (Sweden)

    Hidayat Nur Isnianto

    2013-04-01

    Full Text Available Measurement process of concrete mold erectness (bekesting and the floor slope was generally conducted using conventional method applying a plummet (pendulum for bekesting erectness and waterpass for the floor slope. The drawbacks of this method are it requires a relatively longer processing time and the outcome of the slope measurement is not represented in degrees. The measurement of digital plummet and digital waterpass is easier as the measurement time is relatively short and the tilt angle is represented in degrees. This paper describes a design and implementation of digital plummet and waterpass using Accelero Sensor MMA 7361L based on microcontroller ATmega8. The Accelero sensor MMA 7361L was used to read the tilt axis x, y, and z with analog voltage output that is converted into digital form using the ADC on the microcontroller. Based on the results of tools test for bekesting erectness and floor slope measurement, it was obtained that the average error were 0.51% and 0.49% for x-axis and y-axis respectively.

  4. Does Fundus Fluorescein Angiography Procedure Affect Ocular Pulse Amplitude?

    Directory of Open Access Journals (Sweden)

    Gökhan Pekel

    2013-01-01

    Full Text Available Purpose. This study examines the effects of fundus fluorescein angiography (FFA procedure on ocular pulse amplitude (OPA and intraocular pressure (IOP. Materials and Methods. Sixty eyes of 30 nonproliferative diabetic retinopathy patients (15 males, 15 females were included in this cross-sectional case series. IOP and OPA were measured with the Pascal dynamic contour tonometer before and after 5 minutes of intravenous fluorescein dye injection. Results. Pre-FFA mean OPA value was  mmHg and post-FFA mean OPA value was  mmHg (. Pre-FFA mean IOP value was  mmHg and post-FFA mean IOP value was  mmHg (. Conclusion. Although both mean OPA and IOP values were decreased after FFA procedure, the difference was not statistically significant. This clinical trial is registered with Australian New Zealand Clinical Trials Registry number ACTRN12613000433707.

  5. Standard digital reference images for investment steel castings for aerospace applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 The digital reference images provided in the adjunct to this standard illustrate various types and degrees of discontinuities occurring in thin-wall steel investment castings. Use of this standard for the specification or grading of castings requires procurement of the adjunct digital reference images which illustrate the discontinuity types and severity levels. They are intended to provide the following: 1.1.1 A guide enabling recognition of thin-wall steel casting discontinuities and their differentiation both as to type and degree through digital radiographic examination. 1.1.2 Example digital radiographic illustrations of discontinuities and a nomenclature for reference in acceptance standards, specifications and drawings. 1.2 Two illustration categories are covered as follows: 1.2.1 Graded—Six common discontinuity types each illustrated in eight degrees of progressively increasing severity. 1.2.2 Ungraded—Twelve single illustrations of additional discontinuity types and of patterns and imper...

  6. Digital Mammography Tomosynthesis

    International Nuclear Information System (INIS)

    Gergov, I.; Alexov, G.; Rusonov, K.

    2017-01-01

    Siemens MAMMOMAT Inspiration with Tomosynthesis enhances the diagnostic precision in mammographic screening. The apparatus has a wide-angle tomosynthesis up to 50 degrees. The Siemens breast augmentation algorithm reconstructs multiple two-dimensional breast images into three-dimensional images at the lowest doses to help detect tumors hidden from the overlapping chest tissue, allowing for a more accurate diagnosis than standard 2-dimensional digital mammography, and reducing the number of false positive results. 3D digital tomosynthesis improves the precision of detecting and diagnosing a larger number of expansive lesions, ensures better morphological mass analysis and architectural distortion, and detecting calcifications by adding digital breast tomosynthesis to the traditional two-dimensional digital mammogram of the patient. In this way, it solves the problem of overlapping parenchyma, reduces the number of unnecessary biopsies from questionable sonomammographic findings, and the need for stressful repeating procedures, which usually contributes to both better patient outcomes and cost saving. [bg

  7. Preliminary digital geologic maps of the Mariposa, Kingman, Trona, and Death Valley Sheets, California

    International Nuclear Information System (INIS)

    D'Agnese, F.A.; Faunt, C.C.; Turner, A.K.

    1995-01-01

    Parts of four 1:250,000-scale geologic maps by the California Department of Natural Resources, Division of Mines and Geology have been digitized for use in hydrogeologic characterization. These maps include the area of California between lat. 35 degree N; Long. 115 degree W and lat. 38 degree N, long. 118 degree W of the Kingman Sheet (Jennings, 1961), Trona Sheet (Jennings and others, 1962), Mariposa Sheet (Strand, 1967), and Death Valley Sheet (Streitz and Stinson, 1974). These digital maps are being released by the US Geological Survey in the ARC/INFO Version 6.1 Export format. The digitized data include geologic unit boundaries, fault traces, and identity of geologic units. The procedure outlined in US Geological Survey Circular 1054 (Soller and others, 1990) was sued during the map construction. The procedure involves transferring hard-copy data into digital format by scanning manuscript maps, manipulating the digital map data, and outputting the data. Most of the work was done using Environmental Systems Research Institute's ARC/INFO software. The digital maps are available in ARC/INFO Rev. 6.1 Export format, from the USGS, Yucca Mountain Project, in Denver, Colorado

  8. Diagnostic accuracy of direct ophthalmoscopy for detection of diabetic retinopathy using fundus photographs as a reference standard.

    Science.gov (United States)

    Ahsan, Shahid; Basit, Abdul; Ahmed, Kazi Rumana; Ali, Liaquat; Shaheen, Fariha; Ulhaque, Muhammad Saif; Fawwad, Asher

    2014-01-01

    To determine the diagnostic accuracy of direct ophthalmoscopy for the presence and severity of diabetic retinopathy (DR) using fundus photographs as a reference standard. Patients with type 2 diabetes attending the outpatient department (OPD) of a tertiary care diabetes center, from October 2009 to March 2010 were recruited in the study after obtaining signed informed consent. Patients with type 1 diabetes and gestational diabetes or having eye problems were excluded. After checking visual acuity, direct ophthalmoscopy of each eye was done by diabetologist, followed by photography of two fields of retina by fundus camera. DR was graded by a retinal specialist, according to International Diabetic Retinopathy Disease Severity Scale. According to severity, patients with DR were grouped into non-sight threatening diabetic retinopathy (NSTDR) and sight threatening diabetic retinopathy (STDR). Sensitivity and specificity of direct ophthalmoscopy for detection of any retinopathy, NSTDR and STDR was calculated. A total of 728 eyes were examined by direct ophthalmoscopy as well as fundus photography. Sensitivity (95% CI) of direct ophthalmoscopy for any retinopathy, NSTDR and STDR was found to be 55.67% (50.58-60.78), 37.63% (32.67-42.59) and 68.25% (63.48-73.02) respectively. Whereas, specificity of direct ophthalmoscopy was found to be 76.78% (72.45-81.11), 71.27% (CI: 66.63-75.91) and 90.0% (86.93-93.07) for any retinopathy, NSTDR and STDR respectively. The sensitivity and specificity of direct ophthalmoscopy performed by the diabetologist for the presence and severity of DR was lower compared to the recommended level of sensitivity and specificity of a screening test of DR. Copyright © 2014 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  9. [Evaluation of diabetic retinopathy screening using non-mydriatic fundus camera performed by physicians' assistants in the endocrinology service].

    Science.gov (United States)

    Barcatali, M-G; Denion, E; Miocque, S; Reznik, Y; Joubert, M; Morera, J; Rod, A; Mouriaux, F

    2015-04-01

    Since 2010, the High Authority for health (HAS) recommends the use of non-mydriatic fundus camera for diabetic retinopathy screening. The purpose of this study is to evaluate the results of screening for diabetic retinopathy using the non-mydriatic retinal camera by a physician's assistant in the endocrinology service. This is a retrospective study of all diabetic patients hospitalized in the endocrinology department between May 2013 and November 2013. For each endocrinology patient requiring screening, a previously trained physician's assistant performed fundus photos. The ophthalmologist then provided a written interpretation of the photos on a consultant's sheet. Of the 120 patients screened, 40 (33.3%) patients had uninterpretable photos. Among the 80 interpretable photos, 64 (53.4%) patients had no diabetic retinopathy, and 16 (13.3%) had diabetic retinopathy. No patient had diabetic maculopathy. Specific quality criteria were established by the HAS for screening for diabetic retinopathy using the non-mydriatic retinal camera in order to ensure sufficient sensitivity and specificity. In our study, the two quality criteria were not achieved: the rates of uninterpretable photos and the total number of photos analyzed in a given period. In our center, we discontinued this method of diabetic retinopathy screening due to the high rate of uninterpretable photos. Due to the logistic impossibility of the ophthalmologists taking all the fundus photos, we proposed that the ophthalmic nurses take the photos. They are better trained in the use of the equipment, and can confer directly with an ophthalmologist in questionable cases and to obtain pupil dilation as necessary. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  10. Elliptical Local Vessel Density: a Fast and Robust Quality Metric for Fundus Images

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Chaum, Edward [ORNL; Karnowski, Thomas Paul [ORNL; Meriaudeau, Fabrice [ORNL; Tobin Jr, Kenneth William [ORNL; Abramoff, M.D. [University of Iowa

    2008-01-01

    A great effort of the research community is geared towards the creation of an automatic screening system able to promptly detect diabetic retinopathy with the use of fundus cameras. In addition, there are some documented approaches to the problem of automatically judging the image quality. We propose a new set of features independent of Field of View or resolution to describe the morphology of the patient's vessels. Our initial results suggest that they can be used to estimate the image quality in a time one order of magnitude shorter respect to previous techniques.

  11. THE ALGORITHM OF DETERMINATION OF EYE FUNDUS VESSELS BLOOD FLOW CHARACTERISTICS ON VIDEOSEQUENCE

    Directory of Open Access Journals (Sweden)

    O. V. Nedzvedz

    2018-01-01

    Full Text Available The method of determination of the dynamic characteristics like the vessel diameter change, the linear and volume blood velocities in the vessels of the eye fundus is considered. Such characteristics allow to determine blood flow changes in the microvasculature affecting the blood flow in the brain, kidneys and coronary vessels. Developed algorithm includes four stages: the video sequence stabilization, the vessels segmentation with the help of a neural network, the determination of the instantaneous velocity in the vessels based on the optical flow and the analysis of the results.

  12. The Apparatus of Digital Archaeology

    Directory of Open Access Journals (Sweden)

    Jeremy Huggett

    2017-06-01

    Full Text Available Digital Archaeology is predicated upon an ever-changing set of apparatuses – technological, methodological, software, hardware, material, immaterial – which in their own ways and to varying degrees shape the nature of Digital Archaeology. Our attention, however, is perhaps inevitably more closely focused on research questions, choice of data, and the kinds of analyses and outputs. In the process we tend to overlook the effects the tools themselves have on the archaeology we do beyond the immediate consequences of the digital. This article introduces cognitive artefacts as a means of addressing the apparatus more directly within the context of the developing archaeological digital ecosystem. It argues that a critical appreciation of our computational cognitive artefacts is key to understanding their effects on both our own cognition and on the creation of archaeological knowledge. In the process, it defines a form of cognitive digital archaeology in terms of four distinct methods for extracting cognition from the digital apparatus layer by layer.

  13. Sensitivity and specificity of monochromatic photography of the ocular fundus in differentiating optic nerve head drusen and optic disc oedema: optic disc drusen and oedema.

    Science.gov (United States)

    Gili, Pablo; Flores-Rodríguez, Patricia; Yangüela, Julio; Orduña-Azcona, Javier; Martín-Ríos, María Dolores

    2013-03-01

    Evaluation of the efficacy of monochromatic photography of the ocular fundus in differentiating optic nerve head drusen (ONHD) and optic disc oedema (ODE). Sixty-six patients with ONHD, 31 patients with ODE and 70 healthy subjects were studied. Colour and monochromatic fundus photography with different filters (green, red and autofluorescence) were performed. The results were analysed blindly by two observers. The sensitivity, specificity and interobserver agreement (k) of each test were assessed. Colour photography offers 65.5 % sensitivity and 100 % specificity for the diagnosis of ONHD. Monochromatic photography improves sensitivity and specificity and provides similar results: green filter (71.20 % sensitivity, 96.70 % specificity), red filter (80.30 % sensitivity, 96.80 % specificity), and autofluorescence technique (87.8 % sensitivity, 100 % specificity). The interobserver agreement was good with all techniques used: autofluorescence (k = 0.957), green filter (k = 0.897), red filter (k = 0.818) and colour (k = 0.809). Monochromatic fundus photography permits ONHD and ODE to be differentiated, with good sensitivity and very high specificity. The best results were obtained with autofluorescence and red filter study.

  14. Development of the automatic test pattern generation for NPP digital electronic circuits using the degree of freedom concept

    International Nuclear Information System (INIS)

    Kim, D.S.; Seong, P.H.

    1995-01-01

    In this paper, an improved algorithm for automatic test pattern generation (ATG) for nuclear power plant digital electronic circuits--the combinational type of logic circuits is presented. For accelerating and improving the ATG process for combinational circuits the presented ATG algorithm has the new concept--the degree of freedom (DF). The DF, directly computed from the system descriptions such as types of gates and their interconnections, is the criterion to decide which among several alternate lines' logic values required along each path promises to be the most effective in order to accelerate and improve the ATG process. Based on the DF the proposed ATG algorithm is implemented in the automatic fault diagnosis system (AFDS) which incorporates the advanced fault diagnosis method of artificial intelligence technique, it is shown that the AFDS using the ATG algorithm makes Universal Card (UV Card) testing much faster than the present testing practice or by using exhaustive testing sets

  15. Agreement between optical coherence tomography and fundus fluorescein angiography in post-cataract surgery cystoid macular edema

    Directory of Open Access Journals (Sweden)

    Mitne Somaia

    2003-01-01

    Full Text Available PURPOSE: To evaluate the agreement between optical coherence tomography (OCT and fundus fluorescein angiography (FFA regarding the detection of cystoid macular edema (CME following cataract surgery. METHODS: Retrospective comparative observational series of 25 eyes with suspected CME. Patients with low visual acuity and alterations in fundus biomicroscopy after cataract surgery underwent OCT scanning followed by FFA on the same visit. The diagnosis of CME was established considering fluorescein leakage on FFA and retinal thickness and/or cystoid spaces and/or subretinal fluid on OCT. RESULTS: Twenty-five eyes of 25 patients were enrolled. Twenty-two eyes had similar results on both OCT and FFA, of which 15 eyes had CME and 7 eyes had no CME. Two eyes had CME detected only by FFA and one eye only by OCT. The agreement between the two examinations was good (Kappa = 0.7331; p=0.0001 with no tendency to have neither more positive nor negative findings (p=1.0. CONCLUSION: According to these preliminary data, OCT seems to be as effective as FFA to detect CME with a good agreement between the two techniques.

  16. Retinal pigment epithelial changes in chronic Vogt-Koyanagi-Harada disease: fundus autofluorescence and spectral domain-optical coherence tomography findings.

    Science.gov (United States)

    Vasconcelos-Santos, Daniel V; Sohn, Elliott H; Sadda, Srinivas; Rao, Narsing A

    2010-01-01

    The purpose of this study was to determine whether fundus autofluorescence (FAF) and spectral domain-optical coherence tomography (SD-OCT) imaging allow better assessment of retinal pigment epithelium and the outer retina in subjects with chronic Vogt-Koyanagi-Harada disease compared with examination and angiography alone. A cross-sectional analysis of a series of seven consecutive patients with chronic Vogt-Koyanagi-Harada disease undergoing FAF and SD-OCT was conducted. Chronic disease was defined as duration of intraocular inflammation >3 months. Color fundus photographs were correlated to FAF and SD-OCT images. The images were later correlated to fluorescein angiography and indocyanine green angiography. All patients had sunset glow fundus, which resulted in no apparent corresponding abnormality on FAF or SD-OCT. Lesions with decreased autofluorescence signal were observed in 11 eyes (85%), being associated with loss of the retinal pigment epithelium and involvement of the outer retina on SD-OCT. In 5 eyes (38%), some of these lesions were very subtle on clinical examination but easily detected by FAF. Lesions with increased autofluorescence signal were seen in 8 eyes (61.5%), showing variable involvement of the outer retina on SD-OCT and corresponding clinically to areas of retinal pigment epithelium proliferation and cystoid macular edema. Combined use of FAF and SD-OCT imaging allowed noninvasive delineation of retinal pigment epithelium/outer retina changes in patients with chronic Vogt-Koyanagi-Harada disease, which were consistent with previous histopathologic reports. Some of these changes were not apparent on clinical examination.

  17. An Automated System for the Detection and Classification of Retinal Changes Due to Red Lesions in Longitudinal Fundus Images

    NARCIS (Netherlands)

    Adal, K.M.; Van Etten, Peter G.; Martinez, Jose P; Rouwen, Kenneth W.; Vermeer, K.A.; van Vliet, L.J.

    People with diabetes mellitus need annual screening to check for the development of diabetic retinopathy. Tracking small retinal changes due to early diabetic retinopathy lesions in longitudinal fundus image sets is challenging due to intra- and inter-visit variability in illumination and image

  18. Influence of digitalization on labour relations

    Directory of Open Access Journals (Sweden)

    Jašarević Senad R.

    2016-01-01

    Full Text Available Modern information technology has brought a real revolution in all areas of life and work. The degree of 'digitization' is so great that some authors call this process 'digital revolution', and modern economy - 'digitized economy.' Although it is not so obvious, gradualy is forming a new society - 'digital capitalism'. For 'virtual employers', in the new - 'virtual economy', work 'digital workers' who are mainly invisible and deprived of their labour rights. That's why some call them - 'digital proletariat'. Labour law is slowly adapting to the new circumstances. An increasing number of people remain unprotected or poorly protected. It is necessary to completely re-examine and update the traditional concept of labor law, by expanding access of the labour law to the 'digital workers', modernizing the concept of employment, of an employee, worker, self-employee and employer. Digital technology should be converted into a 'fellow worker' (worker friendly and not a tool of a new form of exploitation. Otherwise, modern 'digitalized society' will turn into a 'community of rightless,' without social and economic perspective.

  19. Fundus autofluorescence in chronic essential hypertension.

    Science.gov (United States)

    Ramezani, Alireza; Saberian, Peyman; Soheilian, Masoud; Parsa, Saeed Alipour; Kamali, Homayoun Koohi; Entezari, Morteza; Shahbazi, Mohammad-Mehdi; Yaseri, Mehdi

    2014-01-01

    To evaluate fundus autofluorescence (FAF) changes in patients with chronic essential hypertension (HTN). In this case-control study, 35 eyes of 35 patients with chronic essential HTN (lasting >5 years) and 31 eyes of 31 volunteers without history of HTN were included. FAF pictures were taken from right eyes of all cases with the Heidelberg retina angiography and then were assessed by two masked retinal specialists. In total, FAF images including 35 images of hypertensive patients and 31 pictures of volunteers, three apparently abnormal patterns were detected. A ring of hyper-autofluorescence in the central macula (doughnut-shaped) was observed in 9 (25.7%) eyes of the hypertensive group but only in 2 (6.5%) eyes of the control group. This difference was statistically significant (P = 0.036) between two groups. Hypo- and/or hyper-autofluorescence patches outside the fovea were the other sign found more in the hypertensive group (22.9%) than in the control group (6.5%); however, the difference was not statistically significant (P = 0.089). The third feature was hypo-autofluorescence around the disk noticed in 11 (31.4%) eyes of hypertensive patients compared to 8 (25.8%) eyes of the controls (P = 0.615). A ring of hyper-autofluorescence in the central macula forming a doughnut-shaped feature may be a FAF sign in patients with chronic essential HTN.

  20. Fundus Autofluorescence in Chronic Essential Hypertension

    Directory of Open Access Journals (Sweden)

    Alireza Ramezani

    2014-01-01

    Full Text Available Purpose: To evaluate fundus autofluorescence (FAF changes in patients with chronic essential hypertension (HTN. Methods: In this case-control study, 35 eyes of 35 patients with chronic essential HTN (lasting >5 years and 31 eyes of 31 volunteers without history of HTN were included. FAF pictures were taken from right eyes of all cases with the Heidelberg retina angiography and then were assessed by two masked retinal specialists. Results: In total, FAF images including 35 images of hypertensive patients and 31 pictures of volunteers, three apparently abnormal patterns were detected. A ring of hyper-autofluorescence in the central macula (doughnut-shaped was observed in 9 (25.7% eyes of the hypertensive group but only in 2 (6.5% eyes of the control group. This difference was statistically significant (P = 0.036 between two groups. Hypo- and/or hyper-autofluorescence patches outside the fovea were the other sign found more in the hypertensive group (22.9% than in the control group (6.5%; however, the difference was not statistically significant (P = 0.089. The third feature was hypo-autofluorescence around the disk noticed in 11 (31.4% eyes of hypertensive patients compared to 8 (25.8% eyes of the controls (P = 0.615. Conclusion: A ring of hyper-autofluorescence in the central macula forming a doughnut-shaped feature may be a FAF sign in patients with chronic essential HTN.

  1. Prevalence of end-digit preference in recorded blood pressure by ...

    African Journals Online (AJOL)

    Objectives: When compared with the use of a mercury sphygmomanometer, the use of a validated digital blood pressure (BP) measuring device eliminates the risk of exposure to mercury. Digital devices are also associated with a lesser degree of end-digit preference (EDP). EDP refers to the occurrence of a particular end ...

  2. Detection of retinal lesions in diabetic retinopathy: comparative evaluation of 7-field digital color photography versus red-free photography.

    Science.gov (United States)

    Venkatesh, Pradeep; Sharma, Reetika; Vashist, Nagender; Vohra, Rajpal; Garg, Satpal

    2015-10-01

    Red-free light allows better detection of vascular lesions as this wavelength is absorbed by hemoglobin; however, the current gold standard for the detection and grading of diabetic retinopathy remains 7-field color fundus photography. The goal of this study was to compare the ability of 7-field fundus photography using red-free light to detect retinopathy lesions with corresponding images captured using standard 7-field color photography. Non-stereoscopic standard 7-field 30° digital color fundus photography and 7-field 30° digital red-free fundus photography were performed in 200 eyes of 103 patients with various grades of diabetic retinopathy ranging from mild to moderate non-proliferative diabetic retinopathy to proliferative diabetic retinopathy. The color images (n = 1,400) were studied with corresponding red-free images (n = 1,400) by one retina consultant (PV) and two senior residents training in retina. The various retinal lesions [microaneurysms, hemorrhages, hard exudates, soft exudates, intra-retinal microvascular anomalies (IRMA), neovascularization of the retina elsewhere (NVE), and neovascularization of the disc (NVD)] detected by all three observers in each of the photographs were noted followed by determination of agreement scores using κ values (range 0-1). Kappa coefficient was categorized as poor (≤0), slight (0.01-0.20), fair (0.2 -0.40), moderate (0.41-0.60), substantial (0.61-0.80), and almost perfect (0.81-1). The number of lesions detected by red-free images alone was higher for all observers and all abnormalities except hard exudates. Detection of IRMA was especially higher for all observers with red-free images. Between image pairs, there was substantial agreement for detection of hard exudates (average κ = 0.62, range 0.60-0.65) and moderate agreement for detection of hemorrhages (average κ = 0.52, range 0.45-0.58), soft exudates (average κ = 0.51, range 0.42-0.61), NVE (average κ = 0.47, range 0.39-0.53), and NVD

  3. Towards Digital Integration

    DEFF Research Database (Denmark)

    Schou, Finn

    2006-01-01

    In 1963, Ivan Sutherland at MIT in his doctoral dissertation, “Sketchpad” introduced a program that has hence been broadly acknowledged as a major step towards drawing digitally. 43 years later the majority of industrial designers within diverse businesses to a high degree still lean upon the use...... of the original “paper and pencil” tools and procedures for conceptual sketching of product style. Through presentation of literature studies and by case studies in the fashion business (eyewear design), this paper puts forward why the penetration of digital tools and methodologies for conceptual styling so far...... has been low. This paper advocates for a paradigm shift. The claim is that implementing digital tools and methodologies is a necessity in order to heighten concept generation productivity - and the outcome. For businesses seeking incremental as well as radical innovation there is no alternative....

  4. The Logic of Digital Platform Disruption

    DEFF Research Database (Denmark)

    Kazan, Erol; Tan, Chee-Wee; Lim, Eric T. K.

    Digital platforms are disruptive IT artifacts, because they facilitate the quick release of innovative platform derivatives from third parties (e.g., apps). This study endeavours to unravel the disruptive potential, caused by distinct designs and configurations of digital platforms on market...... environments. We postulate that the disruptive potential of digital platforms is determined by the degree of alignment among the business, technology and platform profiles. Furthermore, we argue that the design and configuration of the aforementioned three elements dictates the extent to which open innovation...... is permitted. To shed light on the disruptive potential of digital platforms, we opted for payment platforms as our unit of analysis. Through interviews with experts and payment providers, we seek to gain an in-depth appreciation of how contemporary digital payment platforms are designed and configured...

  5. Control Design and Digital Implementation of a Fast 2-Degree-of-Freedom Translational Optical Image Stabilizer for Image Sensors in Mobile Camera Phones.

    Science.gov (United States)

    Wang, Jeremy H-S; Qiu, Kang-Fu; Chao, Paul C-P

    2017-10-13

    This study presents design, digital implementation and performance validation of a lead-lag controller for a 2-degree-of-freedom (DOF) translational optical image stabilizer (OIS) installed with a digital image sensor in mobile camera phones. Nowadays, OIS is an important feature of modern commercial mobile camera phones, which aims to mechanically reduce the image blur caused by hand shaking while shooting photos. The OIS developed in this study is able to move the imaging lens by actuating its voice coil motors (VCMs) at the required speed to the position that significantly compensates for imaging blurs by hand shaking. The compensation proposed is made possible by first establishing the exact, nonlinear equations of motion (EOMs) for the OIS, which is followed by designing a simple lead-lag controller based on established nonlinear EOMs for simple digital computation via a field-programmable gate array (FPGA) board in order to achieve fast response. Finally, experimental validation is conducted to show the favorable performance of the designed OIS; i.e., it is able to stabilize the lens holder to the desired position within 0.02 s, which is much less than previously reported times of around 0.1 s. Also, the resulting residual vibration is less than 2.2-2.5 μm, which is commensurate to the very small pixel size found in most of commercial image sensors; thus, significantly minimizing image blur caused by hand shaking.

  6. Application of 3-Dimensional Printing Technology to Construct an Eye Model for Fundus Viewing Study

    OpenAIRE

    Xie, Ping; Hu, Zizhong; Zhang, Xiaojun; Li, Xinhua; Gao, Zhishan; Yuan, Dongqing; Liu, Qinghuai

    2014-01-01

    Objective To construct a life-sized eye model using the three-dimensional (3D) printing technology for fundus viewing study of the viewing system. Methods We devised our schematic model eye based on Navarro's eye and redesigned some parameters because of the change of the corneal material and the implantation of intraocular lenses (IOLs). Optical performance of our schematic model eye was compared with Navarro's schematic eye and other two reported physical model eyes using the ZEMAX optical ...

  7. Interactive segmentation for geographic atrophy in retinal fundus images.

    Science.gov (United States)

    Lee, Noah; Smith, R Theodore; Laine, Andrew F

    2008-10-01

    Fundus auto-fluorescence (FAF) imaging is a non-invasive technique for in vivo ophthalmoscopic inspection of age-related macular degeneration (AMD), the most common cause of blindness in developed countries. Geographic atrophy (GA) is an advanced form of AMD and accounts for 12-21% of severe visual loss in this disorder [3]. Automatic quantification of GA is important for determining disease progression and facilitating clinical diagnosis of AMD. The problem of automatic segmentation of pathological images still remains an unsolved problem. In this paper we leverage the watershed transform and generalized non-linear gradient operators for interactive segmentation and present an intuitive and simple approach for geographic atrophy segmentation. We compare our approach with the state of the art random walker [5] algorithm for interactive segmentation using ROC statistics. Quantitative evaluation experiments on 100 FAF images show a mean sensitivity/specificity of 98.3/97.7% for our approach and a mean sensitivity/specificity of 88.2/96.6% for the random walker algorithm.

  8. Fundus oculi pigmentation studies simulating the fs-LASIK process

    Energy Technology Data Exchange (ETDEWEB)

    Sander, M; Tetz, M R [Berlin Eye Research Institute, Alt Moabit 101b, 10559 Berlin (Germany); Minet, O; Zabarylo, U [Charite Centrum 6, Arbeitsgruppe Medizinische Physik/Optische Diagnostik, Fabeckstrasse 60–62, 14195 Berlin (Germany); Mueller, M [Augenklinik Ahaus, Am Schlossgraben 13, 48683 Ahaus (Germany)

    2012-06-15

    The femtosecond-laser in situ keratomileusis (fs-LASIK) technique has successfully entered the refractive surgery market to correct ametropia by cutting transparent corneal tissue with ultra-short laser pulses based on photodisruption. The laser pulses in the near infrared range (NIR) generate a laser-induced breakdown (LIOB) in the cornea. By propagating through the eye, a certain amount of the pulse is deposited in the cornea and the remaining energy interacts with the strong absorbing tissue behind. Due to the absorption by the retinal pigment epithelium and the transfer of the thermal energy to surrounding tissue, the transmitted energy can induce damage to the retina. The aim of this project was to find out the threshold influences concerning the tissue and the correlation between the results of the macroscopical appraisal and the fundus oculi pigmentation by simulating the fs-LASIK procedure with two various laser systems in the continuous wave (CW) and fs-regime. Therefore ex-vivo determinations were carried out macroscopically and histopathologically on porcine tissue.

  9. Fundus oculi pigmentation studies simulating the fs-LASIK process

    International Nuclear Information System (INIS)

    Sander, M; Tetz, M R; Minet, O; Zabarylo, U; Mueller, M

    2012-01-01

    The femtosecond-laser in situ keratomileusis (fs-LASIK) technique has successfully entered the refractive surgery market to correct ametropia by cutting transparent corneal tissue with ultra-short laser pulses based on photodisruption. The laser pulses in the near infrared range (NIR) generate a laser-induced breakdown (LIOB) in the cornea. By propagating through the eye, a certain amount of the pulse is deposited in the cornea and the remaining energy interacts with the strong absorbing tissue behind. Due to the absorption by the retinal pigment epithelium and the transfer of the thermal energy to surrounding tissue, the transmitted energy can induce damage to the retina. The aim of this project was to find out the threshold influences concerning the tissue and the correlation between the results of the macroscopical appraisal and the fundus oculi pigmentation by simulating the fs-LASIK procedure with two various laser systems in the continuous wave (CW) and fs-regime. Therefore ex-vivo determinations were carried out macroscopically and histopathologically on porcine tissue

  10. [Method for evaluating the positional accuracy of a six-degrees-of-freedom radiotherapy couch using high definition digital cameras].

    Science.gov (United States)

    Takemura, Akihiro; Ueda, Shinichi; Noto, Kimiya; Kurata, Yuichi; Shoji, Saori

    2011-01-01

    In this study, we proposed and evaluated a positional accuracy assessment method with two high-resolution digital cameras for add-on six-degrees-of-freedom radiotherapy (6D) couches. Two high resolution digital cameras (D5000, Nikon Co.) were used in this accuracy assessment method. These cameras were placed on two orthogonal axes of a linear accelerator (LINAC) coordinate system and focused on the isocenter of the LINAC. Pictures of a needle that was fixed on the 6D couch were taken by the cameras during couch motions of translation and rotation of each axis. The coordinates of the needle in the pictures were obtained using manual measurement, and the coordinate error of the needle was calculated. The accuracy of a HexaPOD evo (Elekta AB, Sweden) was evaluated using this method. All of the mean values of the X, Y, and Z coordinate errors in the translation tests were within ±0.1 mm. However, the standard deviation of the Z coordinate errors in the Z translation test was 0.24 mm, which is higher than the others. In the X rotation test, we found that the X coordinate of the rotational origin of the 6D couch was shifted. We proposed an accuracy assessment method for a 6D couch. The method was able to evaluate the accuracy of the motion of only the 6D couch and revealed the deviation of the origin of the couch rotation. This accuracy assessment method is effective for evaluating add-on 6D couch positioning.

  11. A STUDY TO COMPARE FUNDUS FLUORESCEIN ANGIOGRAPHY AND OPTICAL COHERENCE TOMOGRAPHY IN AGE RELATED MACULAR DEGENERATION

    Directory of Open Access Journals (Sweden)

    Rani Sujatha

    2016-02-01

    Full Text Available PURPOSE To compare the diagnostic accuracy of optical coherence tomography with Fundus Fluorescein Angiography in diagnosing Age related macular degeneration. METHODS A total 25 patients newly diagnosed as Age related macular degeneration were included in the study. The study was done during the time period between August 2013 to November 2015 this is a prospective randomized hospital based study. RESULTS Maximum no of patients affected belonged to the age group of 50-70 years and 60% were females. The most common symptom was defective vision accounting for 92%. Hypertension and hyperlipidemia were the most common risk factors. 12% of the cases had unilateral disease and 88% had bilateral disease. 6% of eyes were normal in both FFA and OCT. 62% of the eyes by FFA and 61% of the eyes by OCT had dry ARMD and 32 % of the eye by FFA and 33 % by OCT had wet ARMD. CONCLUSION Fundus Fluorescein Angiography is the gold standard tool for screening ARMD and OCT is more specific in detecting early subretinal neovascular membrane and also to assess the activity of the neovascular membranes. Hence OCT is superior to FFA in diagnosing early wet ARMD and thus helps in early management of patients with ARMD.

  12. Analysis of the nebulosities near T Tauri using digital computer image processing

    International Nuclear Information System (INIS)

    Lorre, J.J.

    1975-01-01

    Direct plates of T Tauri taken with the 120-inch (3 m) and 36-inch (91 cm) Lick reflectors were digitized and analyzed using digital computer image processing techniques. Luminous emission protrusions extending to as far as 13'' from T Tauri in position angles 170degree, 210degree, and 330degree are shown. These features are variable and may contain layered structure. The complex reflection nebula west of T Tauri (NGC 1555) appears to be an illuminated portion of a much larger dark nebula whose variability is due to obscuring material near the star

  13. Association between fundus autofluorescence and visual outcome in surgically closed macular holes.

    Science.gov (United States)

    Lee, Young Seob; Yu, Seung-Young; Cho, Nam Suk; Kim, Moo Sang; Kim, Young Gyun; Kim, Eung Suk; Kwak, Hyung Woo

    2013-06-01

    To investigate the association between fundus autofluorescence (FAF) and visual acuity, recovery of foveal microstructure, and FAF in surgically closed macular holes. Twenty-six eyes with surgically closed macular hole were classified into two groups based on foveal FAF: normal autofluorescence (NAF) or increased autofluorescence (IAF). The association between foveal FAF and visual acuity was analyzed. In addition, we examined the relationship between recovery of the foveal microstructure assessed by spectral domain optical coherence tomography and FAF after macular hole surgery. At 1 month and 6 months after surgery, there were 9 NAF eyes and 17 IAF eyes. There were no differences between NAF and IAF eyes at 1 month and 6 months after surgery. Preoperative best-corrected visual acuity (logarithm of the minimum angle of resolution) did not differ between groups. Best-corrected visual acuity was significantly higher in the NAF group than in the IAF group at 1 month postoperatively (0.59 ± 0.34 vs. 0.91 ± 0.36, P = 0.044) and tended to be higher at 6 months (0.37 ± 0.38 vs. 0.69 ± 0.53, P = 0.126). Restoration of photoreceptor external limiting membrane differed significantly in 8 NAF eyes (89%) and 4 IAF eyes (24%) at postoperation 1 month (P = 0.001). After 6 months, external limiting membrane was restored in all 9 NAF eyes (100%) and in only 11 IAF eyes (65%) (P = 0.042). Fundus autofluorescence findings observed in surgically closed macular holes correlated with visual improvement and photoreceptor status. Eyes with visual improvement had restoration of normal foveal autofluorescence and retinal microstructure, whereas eyes with persistent foveal hyperautofluorescence did not achieve complete restoration of the retinal microstructure, and visual improvement was not as significant.

  14. Automated diabetic retinopathy detection in smartphone-based fundus photography using artificial intelligence.

    Science.gov (United States)

    Rajalakshmi, Ramachandran; Subashini, Radhakrishnan; Anjana, Ranjit Mohan; Mohan, Viswanathan

    2018-06-01

    To assess the role of artificial intelligence (AI)-based automated software for detection of diabetic retinopathy (DR) and sight-threatening DR (STDR) by fundus photography taken using a smartphone-based device and validate it against ophthalmologist's grading. Three hundred and one patients with type 2 diabetes underwent retinal photography with Remidio 'Fundus on phone' (FOP), a smartphone-based device, at a tertiary care diabetes centre in India. Grading of DR was performed by the ophthalmologists using International Clinical DR (ICDR) classification scale. STDR was defined by the presence of severe non-proliferative DR, proliferative DR or diabetic macular oedema (DME). The retinal photographs were graded using a validated AI DR screening software (EyeArt TM ) designed to identify DR, referable DR (moderate non-proliferative DR or worse and/or DME) or STDR. The sensitivity and specificity of automated grading were assessed and validated against the ophthalmologists' grading. Retinal images of 296 patients were graded. DR was detected by the ophthalmologists in 191 (64.5%) and by the AI software in 203 (68.6%) patients while STDR was detected in 112 (37.8%) and 146 (49.3%) patients, respectively. The AI software showed 95.8% (95% CI 92.9-98.7) sensitivity and 80.2% (95% CI 72.6-87.8) specificity for detecting any DR and 99.1% (95% CI 95.1-99.9) sensitivity and 80.4% (95% CI 73.9-85.9) specificity in detecting STDR with a kappa agreement of k = 0.78 (p < 0.001) and k = 0.75 (p < 0.001), respectively. Automated AI analysis of FOP smartphone retinal imaging has very high sensitivity for detecting DR and STDR and thus can be an initial tool for mass retinal screening in people with diabetes.

  15. THE EFFECT OF PHOTOPIGMENT BLEACHING ON FUNDUS AUTOFLUORESCENCE IN ACUTE CENTRAL SEROUS CHORIORETINOPATHY.

    Science.gov (United States)

    Choi, Kwang-Eon; Yun, Cheolmin; Kim, Young-Ho; Kim, Seong-Woo; Oh, Jaeryung; Huh, Kuhl

    2017-03-01

    To evaluate the effect of photobleaching on fundus autofluorescence (FAF) images in acute central serous chorioretinopathy. We obtained prephotobleaching and postphotobleaching images using an Optomap 200Tx, and photobleaching was induced with a Heidelberg Retina Angiograph 2. Degrees of photobleaching were assessed as grayscale values in Optomap images. Concordances among the three kinds of images were analyzed. Hyper-AF lesions in prephotobleaching images were classified as Type 1 (changed to normal-AF after photobleaching) and Type 2 (unchanged after photobleaching). The FAF composite patterns of central serous chorioretinopathy lesions were classified as diffuse or mottled. Initial and final best-corrected visual acuity, central retinal thickness, and disease duration were compared according to fovea FAF type. Forty-one eyes of 41 patients were analyzed. The lesion brightness of postphotobleaching Optomap FAF showed greater concordance with Heidelberg Retina Angiograph 2 FAF (94.74%) than the prephotobleaching Optomap FAF (80.49%). Eyes with Type 1 fovea had greater initial and final best-corrected visual acuity (20/23 vs. 20/41, 20/21 vs. 20/32, P < 0.0001, P = 0.001, respectively) and shorter disease duration (19.68 ± 12.98 vs. 51.55 ± 44.98 days, P = 0.043) than those with Type 2 fovea. However, eyes with diffuse Type 2 fovea had only lower initial and final best-corrected visual acuity (20/23 vs. 20/45, 20/21 vs. 20/36, P < 0.0001, P < 0.0001, respectively) than those with Type 1 fovea. Understanding the photobleaching effect is necessary for the accurate interpretation of FAF images. Furthermore, comparing prephotobleaching and postphotobleaching FAF images may be helpful for estimation of lesion status in central serous chorioretinopathy.

  16. Exporting Complex Digital Products: Motives and Entry Modes

    DEFF Research Database (Denmark)

    Rask, Morten

    2005-01-01

    When the product is digital, it will most often be distributed directly to the customer through the Internet, and therefore the entry modes, considered in this paper, are different flavors of the entry mode called direct export: Virtual export channel are generally understood as the entry mode fo...... for digital product providers. However other types of entry modes like what wee call direct digital export with F2F-sales, direct digital export with F2F-support and virtual sales subsidiary are entry modes that respond to a higher degree of pre- and after-sales complexity....

  17. Accuracy of deep learning, a machine-learning technology, using ultra-wide-field fundus ophthalmoscopy for detecting rhegmatogenous retinal detachment.

    Science.gov (United States)

    Ohsugi, Hideharu; Tabuchi, Hitoshi; Enno, Hiroki; Ishitobi, Naofumi

    2017-08-25

    Rhegmatogenous retinal detachment (RRD) is a serious condition that can lead to blindness; however, it is highly treatable with timely and appropriate treatment. Thus, early diagnosis and treatment of RRD is crucial. In this study, we applied deep learning, a machine-learning technology, to detect RRD using ultra-wide-field fundus images and investigated its performance. In total, 411 images (329 for training and 82 for grading) from 407 RRD patients and 420 images (336 for training and 84 for grading) from 238 non-RRD patients were used in this study. The deep learning model demonstrated a high sensitivity of 97.6% [95% confidence interval (CI), 94.2-100%] and a high specificity of 96.5% (95% CI, 90.2-100%), and the area under the curve was 0.988 (95% CI, 0.981-0.995). This model can improve medical care in remote areas where eye clinics are not available by using ultra-wide-field fundus ophthalmoscopy for the accurate diagnosis of RRD. Early diagnosis of RRD can prevent blindness.

  18. Towards A Research Agenda on Digital Platform Disruption

    DEFF Research Database (Denmark)

    Kazan, Erol; Tan, Chee-Wee; Lim, Eric T. K.

    Digital platforms are disruptive IT artifacts, because they facilitate the quick release of innovative platform derivatives from third parties. This study endeavors to unravel the disruptive potential, caused by distinct designs and configurations of digital platforms on market environments. We...... postulate that the disruptive potential of digital platforms is determined by the degree of alignment among the business, technology and platform profiles. Furthermore, we argue that the design and configuration of the aforementioned three elements dictates the extent to which open innovation is permitted....... To shed light on the disruptive potential of digital platforms, we opted for digital payment platforms as our unit of analysis. Through interviews with experts and payment providers, we seek to gain an in-depth appreciation of how contemporary digital payment platforms are designed and configured...

  19. Fundus auto fluorescence and spectral domain ocular coherence tomography in the early detection of chloroquine retinopathy

    OpenAIRE

    Megan B. Goodman; Ari Ziskind

    2015-01-01

    Purpose: To determine the sensitivity of spectral domain ocular coherence tomography (SD-OCT) and fundus auto fluorescence (FAF) images as a screening test to detect early changes in the retina prior to the onset of chloroquine retinopathy. Method: The study was conducted using patients taking chloroquine (CQ), referred by the Rheumatology Department to the Ophthalmology Department at Tygerberg Academic Hospital. Group A consisted of 59 patients on CQ for less than 5 years, and Group B co...

  20. Canine and feline fundus photography and videography using a nonpatented 3D printed lens adapter for a smartphone.

    Science.gov (United States)

    Espinheira Gomes, Filipe; Ledbetter, Eric

    2018-05-11

    To describe an indirect funduscopy imaging technique for dogs and cats using low cost and widely available equipment: a smartphone, a three-dimensional (3D) printed indirect lens adapter, and a 40 diopters (D) indirect ophthalmoscopy lens. Fundus videography was performed in dogs and cats using a 40D indirect ophthalmoscopy lens and a smartphone fitted with a 3D printed indirect lens adapter. All animals were pharmacologically dilated with topical tropicamide 1% solution. Eyelid opening and video recording were performed using standard binocular indirect ophthalmoscopy technique. All videos were uploaded to a computer, and still images were selected and acquired for archiving purposes. Fundic images were manipulated to represent the true anatomy of the fundus. It was possible to promptly obtain good quality images from normal and diseased retinas using the nonpatented 3D printed, lens adapter for a smartphone. Fundic imaging using a smartphone can be performed with minimal investment. This simple imaging modality can be used by veterinary ophthalmologists and general practitioners to acquire, archive, and share images of the retina. The quality of images obtained will likely improve with developments in smartphone camera software and hardware. © 2018 American College of Veterinary Ophthalmologists.

  1. Serial imaging and structure-function correlates of high-density rings of fundus autofluorescence in retinitis pigmentosa.

    Science.gov (United States)

    Robson, Anthony G; Tufail, Adnan; Fitzke, Fred; Bird, Alan C; Moore, Anthony T; Holder, Graham E; Webster, Andrew R

    2011-09-01

    To document the evolution and functional and structural significance of parafoveal rings of high-density fundus autofluorescence (AF) in patients with retinitis pigmentosa and preserved visual acuity. Fifty-two patients with nonsyndromic retinitis pigmentosa or Usher syndrome, who had a parafoveal ring of high-density AF and a visual acuity of 20/30 or better, were ascertained. All had international standard full-field electroretinography and pattern electroretinography. Autofluorescence imaging was repeated in 30 patients after periods of up to 9.3 years. Of the 52 patients, 35 underwent optical coherence tomography. Progressive constriction of the ring was detected in 17 patients. Ring radius reduced by up to 40% at a mean rate of between 0.8% and 15.8% per year. In 1 patient, a small ring was replaced by irregular AF; visual acuity deteriorated over the same period. There was a high correspondence between the lateral extent of the preserved optical coherence tomography inner segment/outer segment band and the diameter of the ring along the same optical coherence tomographic scan plane (slope, 0.9; r = 0.97; P retina and preserved photopic function. Serial fundus AF may provide prognostic indicators for preservation of central acuity and potentially assist in the identification and evaluation of patients suitable for treatment aimed at preservation of remaining function.

  2. A multi-scale tensor voting approach for small retinal vessel segmentation in high resolution fundus images.

    Science.gov (United States)

    Christodoulidis, Argyrios; Hurtut, Thomas; Tahar, Houssem Ben; Cheriet, Farida

    2016-09-01

    Segmenting the retinal vessels from fundus images is a prerequisite for many CAD systems for the automatic detection of diabetic retinopathy lesions. So far, research efforts have concentrated mainly on the accurate localization of the large to medium diameter vessels. However, failure to detect the smallest vessels at the segmentation step can lead to false positive lesion detection counts in a subsequent lesion analysis stage. In this study, a new hybrid method for the segmentation of the smallest vessels is proposed. Line detection and perceptual organization techniques are combined in a multi-scale scheme. Small vessels are reconstructed from the perceptual-based approach via tracking and pixel painting. The segmentation was validated in a high resolution fundus image database including healthy and diabetic subjects using pixel-based as well as perceptual-based measures. The proposed method achieves 85.06% sensitivity rate, while the original multi-scale line detection method achieves 81.06% sensitivity rate for the corresponding images (p<0.05). The improvement in the sensitivity rate for the database is 6.47% when only the smallest vessels are considered (p<0.05). For the perceptual-based measure, the proposed method improves the detection of the vasculature by 7.8% against the original multi-scale line detection method (p<0.05). Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Photography or Ophthalmoscopy for Detection of Diabetic Retinopathy?

    NARCIS (Netherlands)

    Leiden, Hendrik A. van; Moll, Annette C.; Dekker, Jacqueline M.; Abramoff, M.D.; Polak, Bettine C.P.

    2003-01-01

    The U.K. National Screening Committee recommended digital fundus photography as the screening method of choice for diabetic retinopathy (DR). However, concerns have been expressed about replacing ophthalmoscopy with slit-lamp biomicroscopy by digital photography. These concerns included the

  4. Extraction of Capillary Non-perfusion from Fundus Fluorescein Angiogram

    Science.gov (United States)

    Sivaswamy, Jayanthi; Agarwal, Amit; Chawla, Mayank; Rani, Alka; Das, Taraprasad

    Capillary Non-Perfusion (CNP) is a condition in diabetic retinopathy where blood ceases to flow to certain parts of the retina, potentially leading to blindness. This paper presents a solution for automatically detecting and segmenting CNP regions from fundus fluorescein angiograms (FFAs). CNPs are modelled as valleys, and a novel technique based on extrema pyramid is presented for trough-based valley detection. The obtained valley points are used to segment the desired CNP regions by employing a variance-based region growing scheme. The proposed algorithm has been tested on 40 images and validated against expert-marked ground truth. In this paper, we present results of testing and validation of our algorithm against ground truth and compare the segmentation performance against two others methods.The performance of the proposed algorithm is presented as a receiver operating characteristic (ROC) curve. The area under this curve is 0.842 and the distance of ROC from the ideal point (0,1) is 0.31. The proposed method for CNP segmentation was found to outperform the watershed [1] and heat-flow [2] based methods.

  5. Digital lattice gauge theories

    Science.gov (United States)

    Zohar, Erez; Farace, Alessandro; Reznik, Benni; Cirac, J. Ignacio

    2017-02-01

    We propose a general scheme for a digital construction of lattice gauge theories with dynamical fermions. In this method, the four-body interactions arising in models with 2 +1 dimensions and higher are obtained stroboscopically, through a sequence of two-body interactions with ancillary degrees of freedom. This yields stronger interactions than the ones obtained through perturbative methods, as typically done in previous proposals, and removes an important bottleneck in the road towards experimental realizations. The scheme applies to generic gauge theories with Lie or finite symmetry groups, both Abelian and non-Abelian. As a concrete example, we present the construction of a digital quantum simulator for a Z3 lattice gauge theory with dynamical fermionic matter in 2 +1 dimensions, using ultracold atoms in optical lattices, involving three atomic species, representing the matter, gauge, and auxiliary degrees of freedom, that are separated in three different layers. By moving the ancilla atoms with a proper sequence of steps, we show how we can obtain the desired evolution in a clean, controlled way.

  6. A Degree Distribution Optimization Algorithm for Image Transmission

    Science.gov (United States)

    Jiang, Wei; Yang, Junjie

    2016-09-01

    Luby Transform (LT) code is the first practical implementation of digital fountain code. The coding behavior of LT code is mainly decided by the degree distribution which determines the relationship between source data and codewords. Two degree distributions are suggested by Luby. They work well in typical situations but not optimally in case of finite encoding symbols. In this work, the degree distribution optimization algorithm is proposed to explore the potential of LT code. Firstly selection scheme of sparse degrees for LT codes is introduced. Then probability distribution is optimized according to the selected degrees. In image transmission, bit stream is sensitive to the channel noise and even a single bit error may cause the loss of synchronization between the encoder and the decoder. Therefore the proposed algorithm is designed for image transmission situation. Moreover, optimal class partition is studied for image transmission with unequal error protection. The experimental results are quite promising. Compared with LT code with robust soliton distribution, the proposed algorithm improves the final quality of recovered images obviously with the same overhead.

  7. [Application of distal palm perforator mini-flap in repair of scar contracture of digital web-spaces].

    Science.gov (United States)

    Zhou, Xiao; Xu, Yajun; Rui, Yongjun; Shou, Kuishui; Yao, Qun

    2011-02-01

    To discuss the effectiveness of distal palm perforator mini-flap in the treatment of scar contracture of digital web-spaces. Between August 2008 and March 2010, 6 cases of scar contracture of digital web-spaces were treated, including 4 males and 2 females and aging 16-68 years (mean, 45 years). The causes were burn injury, twisting injury, and crush injury in 2 cases, respectively. The disease duration was from 3 months to 3 years. The affected digital web-spaces were from index finger to middle finger in 2 cases, from middle finger to ring finger in 3 cases, and from ring finger to small finger in 1 case. The maximum abduction degree of digital web-spaces was 5-10 degrees. The sizes and the depths of reshape of digital web-spaces disappeared. The defect size ranged from 20 mm x 8 mm to 30 mm x 13 mm after opening digital web-spaces. The size of the distal palm perforator mini-flap ranged from 25 mm x 10 mm to 35 mm x 15 mm. The donor sites were sutured directly. All 6 flaps survived and got primary healing. Incisions at donor sites healed by first intention. All patients were followed up 6-12 months. The reconstructed digital web-spaces had good appearance and soft texture. The range of motion of metacarpophalangeal joint was normal. The sizes and the depths of reshape of digital web-spaces were similar to normal ones. The maximum abduction degree of digital web-spaces was 40-60 degrees. There was no scar contracture of incision of palm. The shape of flaps and function of the fingers were satisfactory after 6-12 months of follow-up. It is an ideal method to treat scar contracture of digital web-spaces with distal palm perforator mini-flap.

  8. Detection of motion artifacts in optical coherence tomography using the fundus enhancement system

    International Nuclear Information System (INIS)

    Schaudig, U.; Skevas, C.; Scholz, F.

    2007-01-01

    Extensive artefacts due to major eye movements are detectable in optical coherence tomography images (OCT), but frequency and extent of small eye movements have not been studied. To investigate frequency and extent of irregularities in OCT imaging due to eye movements during the scanning process in OCT. A fundus enhancement system (FES) originally designed to improve retinal image quality in a conventional OCT device (Zeiss Stratus OCT) in order to integrate OCT images into fluorescence angiographies was used to record the scanning process and review OCT-scan acquisition in slow motion. A horizontal and a vertical single line scan of 5 mm length through the center of fixation were obtained in 40 eyes of 20 normal healthy subjects, all with a visual acuity of at least 20/20. Scans were investigated for loss of fixation and eye movements during the scanning process. Outcome measures were presence or absence of eye movements during the scanning process and mean deviation from the intended scan position, measured in millimeter. 7 of 20 patients showed no eye movements in both eyes. 4 of the remaining 13 patients showed eye movements only in one eye. In the eyes with detectable movements, the mean deviation from the intended scan position was 0.2 mm in the horizontal and 0.28 mm in the vertical scans. Fundus imaging in conventional systems can be enhanced to detect artifacts due to minimal eye movements during the scanning process. In this first series with normal healthy subjects, minimal eye movements were present in the over half of the investigations. Although the distances from the intended scan positions seem to be small in normal eyes, further investigations of the phenomenon are necessary. OCT is increasingly used as the primary tool for controlling therapy in macular diseases and the extent of motion artefacts is not known. (author) [de

  9. Radiation dose reduction in the evaluation of scoliosis: an application of digital radiography

    International Nuclear Information System (INIS)

    Kushner, D.C.; Cleveland, R.H.; Herman, T.E.; Zaleske, D.J.; Ehrlich, M.G.; Correia, J.A.

    1986-01-01

    This report documents the clinical testing of scanning beam digital radiography as an imaging method in patients with scoliosis. This type of digital imaging requires a skin exposure of only 2.4 mR (0.619 microC/kg) per image, compared with the lowest possible posteroanterior screen-film exposure of 10 mR (2.58 microC/kg) at the chest and 60 mR (15.48 microC/kg) at the lumbar spine. Digital radiographic and screen-film images were obtained on multiple test objects and 273 patients. Scoliosis measurements using screen-film radiographs and digital radiographs were comparable to within a mean difference of 1 degrees at many different degrees of severity. The low-dose digital images were found to be useful and accurate for the detection and measurement of scoliosis after the first screen-film radiographs have excluded tumors and structural abnormalities

  10. Student Women’s Internet Skills and its Relation with the Digital Inclusion: New Digital Divides

    Directory of Open Access Journals (Sweden)

    Rocío JIMÉNEZ CORTÉS

    2016-12-01

    Full Text Available The aims of this research are to know the women´s internet skills, and form different groups of skills of women related with the digital inclusion. To do this, we surveyed 215 Spanish student women aged 20 to 34 using two escales measuring their internet skills and digital inclusion. The findings show four profiles of student women depending on the types of Internet skills and their developmental level (“beginner”, “average”, “advanced” and specialized in e-administration. The skill to create and share content on social networks and skills for e-administration, along with skills to ensure privacy and security on the Internet are associated with a high degree of digital inclusion for student women. The findings showed that the skills for e-administration and the skills to ensure the security and privacy are the most influential in the digital trust. These results suggest the skills to create and share content in social networks sites makes the basic difference between the “advanced” group and the “specialized in e-administration” group. These results raise educational proposals that prioritize skill’s types to improve digital inclusion in other profiles of women and overcoming new digital divides.

  11. Automated detection of retinal landmarks for the identification of clinically relevant regions in fundus photography

    Science.gov (United States)

    Ometto, Giovanni; Calivá, Francesco; Al-Diri, Bashir; Bek, Toke; Hunter, Andrew

    2016-03-01

    Automatic, quick and reliable identification of retinal landmarks from fundus photography is key for measurements used in research, diagnosis, screening and treating of common diseases affecting the eyes. This study presents a fast method for the detection of the centre of mass of the vascular arcades, optic nerve head (ONH) and fovea, used in the definition of five clinically relevant areas in use for screening programmes for diabetic retinopathy (DR). Thirty-eight fundus photographs showing 7203 DR lesions were analysed to find the landmarks manually by two retina-experts and automatically by the proposed method. The automatic identification of the ONH and fovea were performed using template matching based on normalised cross correlation. The centre of mass of the arcades was obtained by fitting an ellipse on sample coordinates of the main vessels. The coordinates were obtained by processing the image with hessian filtering followed by shape analyses and finally sampling the results. The regions obtained manually and automatically were used to count the retinal lesions falling within, and to evaluate the method. 92.7% of the lesions were falling within the same regions based on the landmarks selected by the two experts. 91.7% and 89.0% were counted in the same areas identified by the method and the first and second expert respectively. The inter-repeatability of the proposed method and the experts is comparable, while the 100% intra-repeatability makes the algorithm a valuable tool in tasks like analyses in real-time, of large datasets and of intra-patient variability.

  12. Diabetic Retinopathy Grading by Digital Curvelet Transform

    Directory of Open Access Journals (Sweden)

    Shirin Hajeb Mohammad Alipour

    2012-01-01

    Full Text Available One of the major complications of diabetes is diabetic retinopathy. As manual analysis and diagnosis of large amount of images are time consuming, automatic detection and grading of diabetic retinopathy are desired. In this paper, we use fundus fluorescein angiography and color fundus images simultaneously, extract 6 features employing curvelet transform, and feed them to support vector machine in order to determine diabetic retinopathy severity stages. These features are area of blood vessels, area, regularity of foveal avascular zone, and the number of micro-aneurisms therein, total number of micro-aneurisms, and area of exudates. In order to extract exudates and vessels, we respectively modify curvelet coefficients of color fundus images and angiograms. The end points of extracted vessels in predefined region of interest based on optic disk are connected together to segment foveal avascular zone region. To extract micro-aneurisms from angiogram, first extracted vessels are subtracted from original image, and after removing detected background by morphological operators and enhancing bright small pixels, micro-aneurisms are detected. 70 patients were involved in this study to classify diabetic retinopathy into 3 groups, that is, (1 no diabetic retinopathy, (2 mild/moderate nonproliferative diabetic retinopathy, (3 severe nonproliferative/proliferative diabetic retinopathy, and our simulations show that the proposed system has sensitivity and specificity of 100% for grading.

  13. Death and digital photography

    Directory of Open Access Journals (Sweden)

    Ennis, Helen

    2011-01-01

    Full Text Available This essay considers new possibilities for photographing the dying and dead in Australia that have been enabled by digital technologies. It argues that vernacular digital photographs demonstrate unprecedented degrees of control and privacy and further that they are purposefully withheld from public view, thus raising issues about visibility and secrecy.Some historical context is provided. Post mortem photographs were not uncommon in the nineteenth century but were in the domain of professional studio photographers. Commissioning post mortem portraits was rare for most of the twentieth century, due to changing attitudes to death and the transformation of the photographic industry. Photographing the deceased re-emerged in the 1980s, notably in the area of neonatal death.In the last five years death-related vernacular photographs have begun to proliferate. Unlike analogue processes, digital photography bypasses the involvement of others in processing and printing private images. Distribution to intimates can be achieved instantaneously via the internet, reinforcing social and familial connections.Vernacular digital photographs of the deceased do not address historical tradition but share their domestic and intimate contexts. Nor do they belong to a unified group, yet they have a common vocabulary which emphasises specificity and detail.

  14. Death and Digital Photography

    Directory of Open Access Journals (Sweden)

    Helen Ennis

    2011-03-01

    Full Text Available This essay considers new possibilities for photographing the dying and dead in Australia that have been enabled by digital technologies. It argues that vernacular digital photographs demonstrate unprecedented degrees of control and privacy and further that they are purposefully withheld from public view, thus raising issues about visibility and secrecy. Some historical context is provided. Post mortem photographs were not uncommon in the nineteenth century but were in the domain of professional studio photographers. Commissioning post mortem portraits was rare for most of the twentieth century, due to changing attitudes to death and the transformation of the photographic industry. Photographing the deceased re-emerged in the 1980s, notably in the area of neonatal death. In the last five years death-related vernacular photographs have begun to proliferate. Unlike analogue processes, digital photography bypasses the involvement of others in processing and printing private images. Distribution to intimates can be achieved instantaneously via the internet, reinforcing social and familial connections. Vernacular digital photographs of the deceased do not address historical tradition but share their domestic and intimate contexts. Nor do they belong to a unified group, yet they have a common vocabulary which emphasises specificity and detail.

  15. Comparison of subjective and objective methods to determine the retinal arterio-venous ratio using fundus photography

    Directory of Open Access Journals (Sweden)

    Rebekka Heitmar

    2015-10-01

    Conclusion: Grader education and experience leads to inter-grader differences but more importantly, subjective grading is not capable to pick up subtle differences across healthy individuals and does not represent true AVR when compared with an objective assessment method. Technology advancements mean we no longer rely on opthalmoscopic evaluation but can capture and store fundus images with retinal cameras, enabling us to measure vessel calibre more accurately compared to visual estimation; hence it should be integrated in optometric practise for improved accuracy and reliability of clinical assessments of retinal vessel calibres.

  16. The Photosensitivity of Rhodopsin Bleaching and Light-Induced Increases of Fundus Reflectance in Mice Measured In Vivo With Scanning Laser Ophthalmoscopy

    Science.gov (United States)

    Zhang, Pengfei; Goswami, Mayank; Zawadzki, Robert J.; Pugh, Edward N.

    2016-01-01

    Purpose To quantify bleaching-induced changes in fundus reflectance in the mouse retina. Methods Light reflected from the fundus of albino (Balb/c) and pigmented (C57Bl/6J) mice was measured with a multichannel scanning laser ophthalmoscopy optical coherence tomography (SLO-OCT) optical system. Serial scanning of small retinal regions was used for bleaching rhodopsin and measuring reflectance changes. Results Serial scanning generated a saturating reflectance increase centered at 501 nm with a photosensitivity of 1.4 × 10−8 per molecule μm2 in both strains, 2-fold higher than expected were irradiance at the rod outer segment base equal to that at the retinal surface. The action spectrum of the reflectance increase corresponds to the absorption spectrum of mouse rhodopsin in situ. Spectra obtained before and after bleaching were fitted with a model of fundus reflectance, quantifying contributions from loss of rhodopsin absorption with bleaching, absorption by oxygenated hemoglobin (HbO2) in the choroid (Balb/c), and absorption by melanin (C57Bl/6J). Both mouse strains exhibited light-induced broadband reflectance changes explained as bleaching-induced reflectivity increases at photoreceptor inner segment/outer segment (IS/OS) junctions and OS tips. Conclusions The elevated photosensitivity of rhodopsin bleaching in vivo is explained by waveguide condensing of light in propagation from rod inner segment (RIS) to rod outer segment (ROS). The similar photosensitivity of rhodopsin in the two strains reveals that little light backscattered from the sclera can enter the ROS. The bleaching-induced increases in reflectance at the IS/OS junctions and OS tips resemble results previously reported in human cones, but are ascribed to rods due to their 30/1 predominance over cones in mice and to the relatively minor amount of cone M-opsin in the regions scanned. PMID:27403994

  17. Automated retinal vessel type classification in color fundus images

    Science.gov (United States)

    Yu, H.; Barriga, S.; Agurto, C.; Nemeth, S.; Bauman, W.; Soliz, P.

    2013-02-01

    Automated retinal vessel type classification is an essential first step toward machine-based quantitative measurement of various vessel topological parameters and identifying vessel abnormalities and alternations in cardiovascular disease risk analysis. This paper presents a new and accurate automatic artery and vein classification method developed for arteriolar-to-venular width ratio (AVR) and artery and vein tortuosity measurements in regions of interest (ROI) of 1.5 and 2.5 optic disc diameters from the disc center, respectively. This method includes illumination normalization, automatic optic disc detection and retinal vessel segmentation, feature extraction, and a partial least squares (PLS) classification. Normalized multi-color information, color variation, and multi-scale morphological features are extracted on each vessel segment. We trained the algorithm on a set of 51 color fundus images using manually marked arteries and veins. We tested the proposed method in a previously unseen test data set consisting of 42 images. We obtained an area under the ROC curve (AUC) of 93.7% in the ROI of AVR measurement and 91.5% of AUC in the ROI of tortuosity measurement. The proposed AV classification method has the potential to assist automatic cardiovascular disease early detection and risk analysis.

  18. Digital Immigrants in Distance Education

    Science.gov (United States)

    Salazar-Márquez, Roberto

    2017-01-01

    The constant growth of methods of education that incorporate the Internet into teaching-learning processes has opened up a wide range of opportunities for students across the world to gain entry to undergraduate or graduate degree programs. However, if the enrolling student is a digital immigrant, the chances of success may be limited by the…

  19. Progression of Stargardt Disease as Determined by Fundus Autofluorescence in the Retrospective Progression of Stargardt Disease Study (ProgStar Report No. 9).

    Science.gov (United States)

    Strauss, Rupert W; Muñoz, Beatriz; Ho, Alexander; Jha, Anamika; Michaelides, Michel; Cideciyan, Artur V; Audo, Isabelle; Birch, David G; Hariri, Amir H; Nittala, Muneeswar G; Sadda, SriniVas; West, Sheila; Scholl, Hendrik P N

    2017-11-01

    Sensitive outcome measures for disease progression are needed for treatment trials of Stargardt disease. To describe the yearly progression rate of atrophic lesions in the retrospective Progression of Stargardt Disease study. A multicenter retrospective cohort study was conducted at tertiary referral centers in the United States and Europe. A total of 251 patients aged 6 years or older at baseline, harboring disease-causing variants in ABCA4 (OMIM 601691), enrolled in the study from 9 centers between August 2, 2013, and December 12, 2014; of these patients, 215 had at least 2 gradable fundus autofluorescence images with atrophic lesion(s) present in at least 1 eye. Areas of definitely decreased autofluorescence (DDAF) and questionably decreased autofluorescence were quantified by a reading center. Progression rates were estimated from linear mixed models with time as the independent variable. Yearly rate of progression using the growth of atrophic lesions measured by fundus autofluorescence. A total of 251 participants (458 study eyes) were enrolled. Images from 386 eyes of 215 participants (126 females and 89 males; mean [SD] age, 29.9 [14.7] years; mean [SD] age of onset of symptoms, 21.9 [13.3] years) showed atrophic lesions present on at least 2 visits and were graded for 2 (156 eyes), 3 (174 eyes), or 4 (57 eyes) visits. A subset of 224 eyes (123 female participants and 101 male participants; mean [SD] age, 33.0 [15.1] years) had areas of DDAF present on at least 2 visits; these eyes were included in the estimation of the progression of the area of DDAF. At the first visit, DDAF was present in 224 eyes (58.0%), with a mean (SD) lesion size of 2.2 (2.7) mm2. The total mean (SD) area of decreased autofluorescence (DDAF and questionably decreased autofluorescence) at first visit was 2.6 (2.8) mm2. Mean progression of DDAF was 0.51 mm2/y (95% CI, 0.42-0.61 mm2/y), and of total decreased fundus autofluorescence was 0.35 mm2/y (95% CI, 0.28-0.43 mm2/y). Rates of

  20. Harvesting the weak angular reflections from the fundus of the human eye : on measuring and analyzing the light wasted by the retina

    NARCIS (Netherlands)

    Kraats, J. van der

    2007-01-01

    Summary of the thesis “Harvesting the weak angular reflections from the fundus of the human eye” by Jan van de Kraats University Medical Centre Utrecht. Defended October 16, 2007. This thesis is on the modeling of the optical reflection of the human fovea, and on the three instruments build for

  1. Primary school teachers' use of digital technology in mathematics: the complexities

    Science.gov (United States)

    Loong, Esther Yook-Kin; Herbert, Sandra

    2018-02-01

    This paper seeks to theorise primary teachers' degree of integration of digital technology in the mathematics classroom. In an age where digital technology use is ubiquitous, the issues surrounding teachers' choice, and ultimately their uptake of digital technologies in the classroom, is an area that need to be further unpacked. Cross-case analysis of the two teachers' uptake of digital technologies in their classroom, their pedagogical approaches and the reason for their choices provide insight into teachers' technological, pedagogical and content knowledge (TPACK). Differences in the way the teachers use digital technology in their classroom seem to be connected to their TPACK developmental stage.

  2. [The cell phones as devices for the ocular fundus documentation].

    Science.gov (United States)

    Němčanský, J; Kopecký, A; Timkovič, J; Mašek, P

    2014-12-01

    To present our experience with "smart phones" when examining and documenting human eyes. From September to October 2013 fifteen patients (8 men, 7 women) eye fundus was examined, an average age during the examination was 58 year (ranging from 20-65 years). The photo-documentation was performed with dilated pupils (tropicamid hydrochloridum 1% eye drops) with mobile phone Samsung Galaxy Nexus with the operating system Android 4.3 (Google Inc., Mountain View, CA, USA) and iPhone 4 with the operating system 7.0.4 (Apple Inc., Loop Cupertino, CA, USA), and with 20D lens (Volk Optical Inc., Mentor, OH, USA). The images of the retina taken with a mobile phone and the spherical lens are of a very good quality, precise and reproducible. Learning this technique is easy and fast, the learning curve is steep. Photo-documentation of retina with a mobile phone is a safe, time-saving, easy-to-learn technique, which may be used in a routine ophthalmologic practice. The main advantage of this technique is availability, small size and easy portability of the devices.

  3. 360-degrees profilometry using strip-light projection coupled to Fourier phase-demodulation.

    Science.gov (United States)

    Servin, Manuel; Padilla, Moises; Garnica, Guillermo

    2016-01-11

    360 degrees (360°) digitalization of three dimensional (3D) solids using a projected light-strip is a well-established technique in academic and commercial profilometers. These profilometers project a light-strip over the digitizing solid while the solid is rotated a full revolution or 360-degrees. Then, a computer program typically extracts the centroid of this light-strip, and by triangulation one obtains the shape of the solid. Here instead of using intensity-based light-strip centroid estimation, we propose to use Fourier phase-demodulation for 360° solid digitalization. The advantage of Fourier demodulation over strip-centroid estimation is that the accuracy of phase-demodulation linearly-increases with the fringe density, while in strip-light the centroid-estimation errors are independent. Here we proposed first to construct a carrier-frequency fringe-pattern by closely adding the individual light-strip images recorded while the solid is being rotated. Next, this high-density fringe-pattern is phase-demodulated using the standard Fourier technique. To test the feasibility of this Fourier demodulation approach, we have digitized two solids with increasing topographic complexity: a Rubik's cube and a plastic model of a human-skull. According to our results, phase demodulation based on the Fourier technique is less noisy than triangulation based on centroid light-strip estimation. Moreover, Fourier demodulation also provides the amplitude of the analytic signal which is a valuable information for the visualization of surface details.

  4. Accuracy of ultra-wide-field fundus ophthalmoscopy-assisted deep learning, a machine-learning technology, for detecting age-related macular degeneration.

    Science.gov (United States)

    Matsuba, Shinji; Tabuchi, Hitoshi; Ohsugi, Hideharu; Enno, Hiroki; Ishitobi, Naofumi; Masumoto, Hiroki; Kiuchi, Yoshiaki

    2018-05-09

    To predict exudative age-related macular degeneration (AMD), we combined a deep convolutional neural network (DCNN), a machine-learning algorithm, with Optos, an ultra-wide-field fundus imaging system. First, to evaluate the diagnostic accuracy of DCNN, 364 photographic images (AMD: 137) were amplified and the area under the curve (AUC), sensitivity and specificity were examined. Furthermore, in order to compare the diagnostic abilities between DCNN and six ophthalmologists, we prepared yield 84 sheets comprising 50% of normal and wet-AMD data each, and calculated the correct answer rate, specificity, sensitivity, and response times. DCNN exhibited 100% sensitivity and 97.31% specificity for wet-AMD images, with an average AUC of 99.76%. Moreover, comparing the diagnostic abilities of DCNN versus six ophthalmologists, the average accuracy of the DCNN was 100%. On the other hand, the accuracy of ophthalmologists, determined only by Optos images without a fundus examination, was 81.9%. A combination of DCNN with Optos images is not better than a medical examination; however, it can identify exudative AMD with a high level of accuracy. Our system is considered useful for screening and telemedicine.

  5. A Comparative Study of Digital Library Use: Factors, Perceived Influences, and Satisfaction

    Science.gov (United States)

    Liu, Ziming; Luo, Lili

    2011-01-01

    This study explores the extent to which undergraduate and graduate students in China differ in their digital library use. Unlike the factors promoting digital library use, non-use factors, perceived influences, and degree of satisfaction are quite different between undergraduate and graduate students due to their differing emphases and…

  6. COMPARISON OF MANUAL AND SEMIAUTOMATED FUNDUS AUTOFLUORESCENCE ANALYSIS OF MACULAR ATROPHY IN STARGARDT DISEASE PHENOTYPE.

    Science.gov (United States)

    Kuehlewein, Laura; Hariri, Amir H; Ho, Alexander; Dustin, Laurie; Wolfson, Yulia; Strauss, Rupert W; Scholl, Hendrik P N; Sadda, SriniVas R

    2016-06-01

    To evaluate manual and semiautomated grading techniques for assessing decreased fundus autofluorescence (DAF) in patients with Stargardt disease phenotype. Certified reading center graders performed manual and semiautomated (region finder-based) grading of confocal scanning laser ophthalmoscopy (cSLO) fundus autofluorescence (FAF) images for 41 eyes of 22 patients. Lesion types were defined based on the black level and sharpness of the border: definite decreased autofluorescence (DDAF), well, and poorly demarcated questionably decreased autofluorescence (WDQDAF, PDQDAF). Agreement in grading between the two methods and inter- and intra-grader agreement was assessed by kappa coefficients (κ) and intraclass correlation coefficients (ICC). The mean ± standard deviation (SD) area was 3.07 ± 3.02 mm for DDAF (n = 31), 1.53 ± 1.52 mm for WDQDAF (n = 9), and 6.94 ± 10.06 mm for PDQDAF (n = 17). The mean ± SD absolute difference in area between manual and semiautomated grading was 0.26 ± 0.28 mm for DDAF, 0.20 ± 0.26 mm for WDQDAF, and 4.05 ± 8.32 mm for PDQDAF. The ICC (95% confidence interval) for method comparison was 0.992 (0.984-0.996) for DDAF, 0.976 (0.922-0.993) for WDQDAF, and 0.648 (0.306-0.842) for PDQDAF. Inter- and intra-grader agreement in manual and semiautomated quantitative grading was better for DDAF (0.981-0.996) and WDQDAF (0.995-0.999) than for PDQDAF (0.715-0.993). Manual and semiautomated grading methods showed similar levels of reproducibility for assessing areas of decreased autofluorescence in patients with Stargardt disease phenotype. Excellent agreement and reproducibility were observed for well demarcated lesions.

  7. Measurement Invariance of the Digital Natives Assessment Scale across Gender in a Sample of Turkish University Students

    Science.gov (United States)

    Ursavas, Ömer Faruk; Kabakçi Yurdakul, Isil; Türk, Mesut; Mcilroy, David

    2016-01-01

    With reference to the digital natives' debate, there is a gap on digital natives' characteristics. To fill this gap, the Digital Natives Assessment Scale was developed to measure students' assessment of the degree to which they perceived themselves to possess the attributes of digital natives. The scale was developed within the Turkish language…

  8. Digital Game-Based Learning: A Didactic Experience in the Pre-Degree Nursing Career.

    Science.gov (United States)

    Solís de Ovando, A; Rodríguez, A; Hullin, C

    2018-01-01

    Nowadays we are faced with a society immersed in globalization and native technology, causing a great challenge in the university teaching staff. The gamification, as teaching-learning didactic methodology, gathers the characteristics that allow to motivate and achieve an active and significant learning. The objective of this work is to show the experience of the nursing career, which combines the learning based on games and the use of digital applications.

  9. Fundus fluorescence Angiography in diagnosing diabetic retinopathy.

    Science.gov (United States)

    Wang, Shuhui; Zuo, Yuqin; Wang, Ning; Tong, Bin

    2017-01-01

    To investigate the manifestation characteristics of fundus fluorescence angiography (FFA) and its values in diagnosing diabetic retinopathy through comparing direct ophthalmoscopy. Two hundred fifty patients (500 eyes) who were suspected as diabetic retinopathy and admitted to the hospital between February 2015 and December 2016 were selected. They underwent direct ophthalmoscopy and FFA. The manifestation characteristics of FFA in the diagnosis of diabetic retinopathy were summarized. The two examination methods were compared. In the diagnosis with direct ophthalmoscopy, 375 eyes out of 500 eyes were diagnosed as diabetic retinopathy (75%); there were 74 eyes at stage I, 88 eyes at stage II, 92 eyes at stage III, 83 eyes of stage IV, 28 eyes of stage V and 10 eyes of stage VI. In the diagnosis with FFA, 465 eyes out of 500 eyes were diagnosed as diabetic retinopathy (93%); there were 94 eyes at stage I, 110 eyes at stage II, 112 at stage III, 92 eyes at stage IV, 41 eyes at stage V and 16 eyes at stage VI. The detection rate of diabetic retinopathy using FFA was significantly higher than that using direct ophthalmoscopy (Pretinopathy (67.96%), 75 eyes had pre-proliferative lesions (16.13%), 149 eyes had proliferative lesions (32.04%), 135 eyes had diabetic maculopathy (29.03%) and 31 eyes had diabetic optic disc lesions (6.67%). The detection rate of diabetic retinopathy using FFA is higher than that using direct ophthalmoscopy. FFA could accurately determine clinical stage. Therefore, it is an important approach in treatment efficacy evaluation and treatment guidance, suggesting a significant application value.

  10. The role of the teacher degree and his involvement with the digital humanities

    Directory of Open Access Journals (Sweden)

    Daniel Rodrigo-Cano

    2018-05-01

    Full Text Available The technological convergence is leading to rapid change in the communicative context and, above all, education. In this sense, the present investigation tries to analyze a twofold: on the one hand, identify the skills of university professors to the digital humanities for social learning and, on the other hand, recognize the good university practices, to identify the most widely used tools, as well as the motivations that lead to success in the collaborative methodologies in Web 2.0. Following this, the research is focused through a qualitative-quantitative methodology with the collection of 537 questionnaires made up of students and the development of a focus groups with a total of 20 teachers belonging to the University of Cadiz, Seville and Huelva. In this sense, it can be noted, among the most outstanding results, that the use of new technologies in the classroom is taking a visible role, both from the point of view of the student and the professor for teaching in a collaborative manner and to develop a critical attitude to the current context. Therefore, it is important to establish that, in times of digital humanities teachers must seek to empower the university students so that they acquire skills how to enter critical discourses.

  11. Emotional reactions of different interface formats: Comparing digital and traditional board games

    Directory of Open Access Journals (Sweden)

    Yu-Min Fang

    2016-03-01

    Full Text Available Some games provide both traditional board games and digital versions at the same time in the market. Why the rise of virtual games has not forced traditional physical board games to disappear? Do traditional physical games evoke different emotional reactions and interpersonal relationships? This article explored the subjects’ preferences toward traditional and digital versions of the same game and investigated social interaction while playing games. Based on Norman’s three emotional design levels—visceral, behavioral, and reflective levels—this study examined players’ satisfaction degree. This study also applied Positive and Negative Affect Schedule to measure subjects’ emotional reactions. Monopoly and Jenga games were selected as stimuli. A total of 77 subjects received tests of three different interface formats (physical, desktop, and tablet and then filled out the questionnaire. The findings successfully evidenced the significant differences between digital and traditional board games. The statistical results indicated that satisfaction degrees of digital games declined in visceral, behavioral, and reflective levels. Traditional games not only evoked users’ stronger emotional reactions but also received higher preferences. Traditional games could improve interpersonal relationships as well.

  12. Digital Blood Flow In Systemic Lupus Erythematosus By Photoplethysmography

    Directory of Open Access Journals (Sweden)

    Ghosh Sanjay

    2002-01-01

    Full Text Available Digital vascular status in 10 patients of systemic lupus erythematous (SLE suffering for 1 to 5 years and 5 control (normal subjects was assessed by a highly sensitive, non-invasive technique called photoplethysmography (PPG. Six patients (Group A showed clinical sign. PPG recordings were done by applying the PPG probe serially to the distal phalanges of all the digits of four limbs with Velcro-strap at an ambient temperature of 27 to 31C and humidity 60 to 65% Diminished capillary flow. On average, 12 digits (60% in Group A and 8 digits (40% in group B patients showed reduced blood circulation. Degree of vascular impairment had no bearing upon the duration of the disease. The PPG has objectively shown digital vascular impairment in all SLE patients having no correlation with the extent of clinical manifestations and the duration of the disease.

  13. Dental practitioners and a digital future: an initial exploration of barriers and incentives to adopting digital technologies.

    Science.gov (United States)

    van der Zande, M M; Gorter, R C; Wismeijer, D

    2013-12-01

    Digital technologies are proliferating into dental practices. While their technical attributes have often been studied, it remains unclear why some dentists adopt and use these technologies more than others. AIM To explore the incentives for and barriers against accepting and using digital dental technologies. Eleven semi-structured qualitative interviews were conducted with experts in dentistry, dental technology and dental education in the Netherlands. Dentists' acceptance and use of digital technologies are to varying degrees driven by the perceived advantages over analogue methods, perceived influence on treatment quality, dentists' personal and professional orientation, and social influence from peers and external groups. These effects are complemented by personal and dental-practice characteristics. The findings suggest that there are large differences in motivation to adopt and use digital technologies between early adopters, late adopters and non-adopters, which should be examined in greater detail. We recommend that educators, dentists, and representatives of the dental industry who deal with the diffusion of these technologies take account of dentists' widely different attitudes to digitalisation.

  14. #DigitalHealth: Exploring Users' Perspectives through Social Media Analysis.

    Science.gov (United States)

    Afyouni, Soroosh; Fetit, Ahmed E; Arvanitis, Theodoros N

    2015-01-01

    In order to explore the role of social media in forming an understanding of digital healthcare, we conducted a study involving sentiment and network analysis of Twitter contents. In doing this, we gathered 20,400 tweets that mentioned the key term #DigitalHealth for 55 hours, over a three-day period. In addition to examining users' opinions through sentiment analysis, we calculated in-degree centralities of nodes to identify the hubs in the network of interactions. The results suggest that the overall opinion about digital healthcare is generally positive. Additionally, our findings indicate that the most prevalent keywords, associated with digital health, widely range from mobile health to wearable technologies and big data. Surprisingly, the results show that the newly announced wearable technologies could occupy the majority of discussions.

  15. Assessing diabetic retinopathy using two-field digital photography and the influence of JPEG-comoression

    NARCIS (Netherlands)

    Stellingwerf, C; Hardus, PLLJ; Hooymans, JMM

    Objective: To study the effectiveness of two digital 50degrees photographic fields per eye, stored compressed or integrally, in the grading of diabetic retinopathy, in comparison to 35-mm colour slides. Subjects and methods: Two-field digital non-stereoscopic retinal photographs and two-field 35-mm

  16. Classification of Diabetic Macular Edema and Its Stages Using Color Fundus Image

    Institute of Scientific and Technical Information of China (English)

    Muhammad Zubair; Shoab A. Khan; Ubaid Ullah Yasin

    2014-01-01

    Diabetic macular edema (DME) is a retinal thickening involving the center of the macula. It is one of the serious eye diseases which affects the central vision and can lead to partial or even complete visual loss. The only cure is timely diagnosis, prevention, and treatment of the disease. This paper presents an automated system for the diagnosis and classification of DME using color fundus image. In the proposed technique, first the optic disc is removed by applying some preprocessing steps. The preprocessed image is then passed through a classifier for segmentation of the image to detect exudates. The classifier uses dynamic thresholding technique by using some input parameters of the image. The stage classification is done on the basis of anearly treatment diabetic retinopathy study (ETDRS) given criteria to assess the severity of disease. The proposed technique gives a sensitivity, specificity, and accuracy of 98.27%, 96.58%, and 96.54%, respectively on publically available database.

  17. Year 2000: status of picture archiving and digital imaging in European hospitals

    International Nuclear Information System (INIS)

    Foord, K.

    2001-01-01

    The aim of this study was to compare the degrees of implementations of full and departmental Picture Archiving and Communication Systems (PACS), the usage of mini-PACS and to compare digital image equipment implementation rates in the countries of the European Union plus the Czech Republic, Cyprus, Malta, Norway, Poland and Switzerland. The degree to which Digital Image Communications in Medicine version 3.0 (DICOM 3.0) protocols are available for data exchange by different digital image equipment is surveyed, to assess underlying PACS preparedness. A questionnaire with an addressed reply envelope was posted to the heads of radiology of 1594 hospitals in 19 countries in early 2000. Data returns were obtained from 17 countries. This indicates considerable variation in PACS implementation and preparedness between European nations. Possible reasons for this are discussed. The highest rates of PACS implementations have been in Austria, Norway and Sweden. (orig.)

  18. Degree-degree correlations in random graphs with heavy-tailed degrees

    NARCIS (Netherlands)

    Hofstad, van der R.W.; Litvak, N.

    2014-01-01

    Mixing patterns in large self-organizing networks, such as the Internet, the World Wide Web, social, and biological networks are often characterized by degree-degree dependencies between neighboring nodes. In assortative networks, the degree-degree dependencies are positive (nodes with similar

  19. Degree-Degree Dependencies in Random Graphs with Heavy-Tailed Degrees

    NARCIS (Netherlands)

    van der Hofstad, Remco; Litvak, Nelly

    2014-01-01

    Mixing patterns in large self-organizing networks, such as the Internet, the World Wide Web, social, and biological networks are often characterized by degree-degree dependencies between neighboring nodes. In assortative networks, the degree-degree dependencies are positive (nodes with similar

  20. Deep Convolutional Neural Network-Based Early Automated Detection of Diabetic Retinopathy Using Fundus Image.

    Science.gov (United States)

    Xu, Kele; Feng, Dawei; Mi, Haibo

    2017-11-23

    The automatic detection of diabetic retinopathy is of vital importance, as it is the main cause of irreversible vision loss in the working-age population in the developed world. The early detection of diabetic retinopathy occurrence can be very helpful for clinical treatment; although several different feature extraction approaches have been proposed, the classification task for retinal images is still tedious even for those trained clinicians. Recently, deep convolutional neural networks have manifested superior performance in image classification compared to previous handcrafted feature-based image classification methods. Thus, in this paper, we explored the use of deep convolutional neural network methodology for the automatic classification of diabetic retinopathy using color fundus image, and obtained an accuracy of 94.5% on our dataset, outperforming the results obtained by using classical approaches.

  1. Electronic Referrals and Digital Imaging Systems in Ophthalmology: A Global Perspective.

    Science.gov (United States)

    Jeganathan, V Swetha E; Hall, H Nikki; Sanders, Roshini

    2017-01-01

    Ophthalmology departments face intensifying pressure to expedite sight-saving treatments and reduce the global burden of disease. The use of electronic communication systems, digital imaging, and redesigned service care models is imperative for addressing such demands. The recently developed Scottish Eyecare Integration Project involves an electronic referral system from community optometry to the hospital ophthalmology department using National Health Service (NHS) email with digital ophthalmic images attached, via a virtual private network connection. The benefits over the previous system include reduced waiting times, improved triage, e-diagnosis in 20% without the need for hospital attendance, and rapid electronic feedback to referrers. We draw on the experience of the Scottish Eyecare Integration Project and discuss the global applications of this and other advances in teleophthalmology. We focus particularly on the implications for management and screening of chronic disease, such as glaucoma and diabetic eye disease, and ophthalmic disease, such as retinopathy of prematurity where diagnosis is almost entirely and critically dependent on fundus appearance. Currently in Scotland, approximately 75% of all referrals are electronic from community to hospital. The Scottish Eyecare Integration Project is globally the first of its kind and unique in a national health service. Such speedy, safe, and efficient models of communication are geographically sensitive to service provision, especially in remote and rural regions. Along with advances in teleophthalmology, such systems promote the earlier detection of sight-threatening disease and safe follow-up of non-sight-threatening disease in the community. Copyright© 2017 Asia-Pacific Academy of Ophthalmology.

  2. 360-degree interactive video application for Cultural Heritage Education

    OpenAIRE

    Argyriou, L.; Economou, D.; Bouki, V.

    2017-01-01

    There is a growing interest nowadays of using immersive technologies to promote Cultural Heritage (CH), engage and educate visitors, tourists and citizens. Such examples refer mainly to the use of Virtual Reality (VR) technology or focus on the enhancement of the real world by superimposing digital artefacts, so called Augmented Reality (AR) applications. A new medium that has been introduced lately as an innovative form of experiencing immersion is the 360-degree video, imposing further rese...

  3. Oral-facial-digital syndrome type 1: Report of a case

    Directory of Open Access Journals (Sweden)

    Peter W Duda

    2014-01-01

    Full Text Available Oral-facial-digital syndrome (OFD is a collective term describing thirteen distinctive, rare genetic disorders based on inheritance pattern and phenotypic expression. OFD is characterized by malformations of the oral cavity, the maxillofacial region and the arms and legs. Central nervous system anomalies, include intracerebral cysts, agenesis of the corpus callosum, hydrocephalus, cerebral/cerebellar atrophy, and berry aneurysms. Some degree of compromised intellectual ability and speech are present in affected individuals that correlate with the degree of central nervous system involvement. Furthermore, renal involvement in the form of polycystic kidney disease is evident in affected individuals in adulthood. In this article, we present a 37-year-old female patient that presented to the Rutgers School of Dental Medicine with oral-facial-digital syndrome, type 1.

  4. A new IPQAM modulator with high integrated degree for digital TV

    Science.gov (United States)

    He, Yejun; Liu, Deming; Zhu, Guangxi; Jiang, Tao; Sun, Gongxian

    2008-12-01

    As video on demand (VOD) services are deployed, cable operators will experience a fundamental shift in their business, moving from broadcast to unicast content delivery. Another significant change is the introduction of Gigabit Ethernet into their network, which is providing an unprecedented opportunity to turn the cable operator's infrastructure into a sustainable competitive advantage. However, Gigabit Ethernet is more than just transport; it's the foundation of the Next-Generation Digital Video Network. IPQAM modulator, which is a main equipment, aren't made in China so far. It is the first time that we did design IPQAM modulator and will apply it to interactive TV based on DWDM (dense wavelength-division multiplexing). This paper introduces the principle of IPQAM modulator and transmission approach. The differences between IPQAM and conventional QAM are analysed. Some key techniques such as scrambling, statistical multiplexing, Data over Cable Service Interface Specification (DOCSIS) 3.0, software defined radio as well as DVB simulcrypt are also studied.

  5. Digital Culture and Digital Library

    Directory of Open Access Journals (Sweden)

    Yalçın Yalçınkaya

    2016-12-01

    Full Text Available In this study; digital culture and digital library which have a vital connection with each other are examined together. The content of the research consists of the interaction of culture, information, digital culture, intellectual technologies, and digital library concepts. The study is an entry work to integrity of digital culture and digital library theories and aims to expand the symmetry. The purpose of the study is to emphasize the relation between the digital culture and digital library theories acting intersection of the subjects that are examined. Also the perspective of the study is based on examining the literature and analytical evaluation in both studies (digital culture and digital library. Within this context, the methodology of the study is essentially descriptive and has an attribute for the transmission and synthesis of distributed findings produced in the field of the research. According to the findings of the study results, digital culture is an inclusive term that describes the effects of intellectual technologies in the field of information and communication. Information becomes energy and the spectrum of the information is expanding in the vertical rise through the digital culture. In this context, the digital library appears as a new living space of a new environment. In essence, the digital library is information-oriented; has intellectual technology support and digital platform; is in a digital format; combines information resources and tools in relationship/communication/cooperation by connectedness, and also it is the dynamic face of the digital culture in time and space independence. Resolved with the study is that the digital libraries are active and effective in the formation of global knowing and/or mass wisdom in the process of digital culture.

  6. 3D Reconstruction of the Retinal Arterial Tree Using Subject-Specific Fundus Images

    Science.gov (United States)

    Liu, D.; Wood, N. B.; Xu, X. Y.; Witt, N.; Hughes, A. D.; Samcg, Thom

    Systemic diseases, such as hypertension and diabetes, are associated with changes in the retinal microvasculature. Although a number of studies have been performed on the quantitative assessment of the geometrical patterns of the retinal vasculature, previous work has been confined to 2 dimensional (2D) analyses. In this paper, we present an approach to obtain a 3D reconstruction of the retinal arteries from a pair of 2D retinal images acquired in vivo. A simple essential matrix based self-calibration approach was employed for the "fundus camera-eye" system. Vessel segmentation was performed using a semi-automatic approach and correspondence between points from different images was calculated. The results of 3D reconstruction show the centreline of retinal vessels and their 3D curvature clearly. Three-dimensional reconstruction of the retinal vessels is feasible and may be useful in future studies of the retinal vasculature in disease.

  7. Digital laminography assessment of the damage in concrete exposed to freezing temperatures

    KAUST Repository

    Wakimoto, Kentaro

    2008-10-01

    The research explores the possibility of using digital laminography as a non-destructive inspection X-ray method to image the damage existing in concrete exposed to low temperatures. Freezing-thawing and scaling tests were performed and digital laminography was used to determine the degree of damage existing inside the concrete samples. First, digital laminography was performed on the concrete sample and then a visual inspection was done by slicing the sample after it was vacuum-impregnated with epoxy in order to compare the differences in crack width. © 2008 Elsevier Ltd. All rights reserved.

  8. Digital laminography assessment of the damage in concrete exposed to freezing temperatures

    KAUST Repository

    Wakimoto, Kentaro; Blunt, Joshua; Carlos, Cruz; Monteiro, Paulo J.M.; Ostertag, Claudia P.; Albert, Richard

    2008-01-01

    The research explores the possibility of using digital laminography as a non-destructive inspection X-ray method to image the damage existing in concrete exposed to low temperatures. Freezing-thawing and scaling tests were performed and digital laminography was used to determine the degree of damage existing inside the concrete samples. First, digital laminography was performed on the concrete sample and then a visual inspection was done by slicing the sample after it was vacuum-impregnated with epoxy in order to compare the differences in crack width. © 2008 Elsevier Ltd. All rights reserved.

  9. Immediate and long-term changes of fundus autofluorescence in continuous wave laser lesions of the retina.

    Science.gov (United States)

    Framme, Carsten; Roider, Johann

    2004-01-01

    To determine whether fundus autofluorescence imaging is able to show changes in retinal pigment epithelium (RPE) fluorescence after thermal laser photocoagulation. In vivo imaging of fundus autofluorescence was performed with a scanning laser ophthalmoscope. A laser with a wavelength of 488 nm was used for excitation of the tissue and autofluorescence was detected above 500 nm using a barrier filter. One hundred eight eyes of 87 patients who had had previous laser treatment were monitored. The appearance and size of the laser lesions were documented and correlated to the time of treatment. Immediate changes were observed prospectively in 13 eyes; long-term follow-up was studied retrospectively in 95 eyes. In all patients but one, autofluorescence was decreased in the area of laser lesions 1 hour after laser treatment. After 1 month, previously decreased autofluorescence in all lesions changed to significantly increased autofluorescence, which was stable up to 6 months after treatment. Mixed forms were present approximately 6 to 12 months after treatment, showing a central island of increased autofluorescence surrounded by a ring of decreased autofluorescence. After 1 to 2 years, lesions again changed to complete dark spots, enlarging later on. RPE destruction and subsequent proliferation after continuous wave laser photocoagulation can be visualized noninvasively by autofluorescence imaging. Immediate decreased autofluorescence may indicate acute damage of the RPE, subsequent increased autofluorescence seems to indicate proliferative behavior of the RPE, and final dark spots can indicate RPE atrophy secondary to a denaturation of neurosensory retinal tissue. Thus, autofluorescence can be used in the long-term monitoring of RPE changes after laser treatment. The enlargement of the laser atrophy zone demonstrates the potential risk of visual loss after central laser photocoagulation even years after treatment.

  10. Correlation between peripapillary retinal nerve fiber layer thickness and fundus autofluorescence in primary open-angle glaucoma

    Directory of Open Access Journals (Sweden)

    Reznicek L

    2013-09-01

    Full Text Available Lukas Reznicek,* Florian Seidensticker,* Thomas Mann, Irene Hübert, Alexandra Buerger, Christos Haritoglou, Aljoscha S Neubauer, Anselm Kampik, Christoph Hirneiss, Marcus Kernt Department of Ophthalmology, Ludwig-Maximilians-University, Munich, Germany *These authors contributed equally to this work Purpose: To investigate the relationship between retinal nerve fiber layer (RNFL thickness and retinal pigment epithelium alterations in patients with advanced glaucomatous visual field defects. Methods: A consecutive, prospective series of 82 study eyes with primary open-angle glaucoma and advanced glaucomatous visual field defects were included in this study. All study participants underwent a full ophthalmic examination followed by visual field testing with standard automated perimetry as well as spectral-domain optical coherence tomography (SD-OCT for peripapillary RNFL thickness and Optos wide-field fundus autofluorescence (FAF images. A pattern grid with corresponding locations between functional visual field sectors and structural peripapillary RNFL thickness was aligned to the FAF images at corresponding location. Mean FAF intensity (range: 0 = black and 255 = white of each evaluated sector (superotemporal, temporal, inferotemporal, inferonasal, nasal, superonasal was correlated with the corresponding peripapillary RNFL thickness obtained with SD-OCT. Results: Correlation analyses between sectoral RNFL thickness and standardized FAF intensity in the corresponding topographic retina segments revealed partly significant correlations with correlation coefficients ranging between 0.004 and 0.376 and were statistically significant in the temporal inferior central field (r = 0.324, P = 0.036 and the nasal field (r = 0.376, P = 0.014. Conclusion: Retinal pigment epithelium abnormalities correlate with corresponding peripapillary RNFL damage, especially in the temporal inferior sector of patients with advanced glaucomatous visual field defects. A

  11. Summary of: dental practitioners and a digital future: an initial exploration of barriers and incentives to adopting digital technologies.

    Science.gov (United States)

    Addy, Liam

    2013-12-01

    Digital technologies are proliferating into dental practices. While their technical attributes have often been studied, it remains unclear why some dentists adopt and use these technologies more than others. AIM To explore the incentives for and barriers against accepting and using digital dental technologies. Eleven semi-structured qualitative interviews were conducted with experts in dentistry, dental technology and dental education in the Netherlands. Dentists' acceptance and use of digital technologies are to varying degrees driven by the perceived advantages over analogue methods, perceived influence on treatment quality, dentists' personal and professional orientation, and social influence from peers and external groups. These effects are complemented by personal and dental-practice characteristics. The findings suggest that there are large differences in motivation to adopt and use digital technologies between early adopters, late adopters and non-adopters, which should be examined in greater detail. We recommend that educators, dentists, and representatives of the dental industry who deal with the diffusion of these technologies take account of dentists' widely different attitudes to digitalisation.

  12. MACULAR ATROPHY FINDINGS BY OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY COMPARED WITH FUNDUS AUTOFLUORESCENCE IN TREATED EXUDATIVE AGE-RELATED MACULAR DEGENERATION.

    Science.gov (United States)

    Takasago, Yukari; Shiragami, Chieko; Kobayashi, Mamoru; Osaka, Rie; Ono, Aoi; Yamashita, Ayana; Tsujikawa, Akitaka; Hirooka, Kazuyuki

    2017-11-28

    To compare the areas of choriocapillaris (CC) nonperfusion and macular atrophy (MA) in treated exudative age-related macular degeneration. This was a prospective, observational, cross-sectional study. Forty-four eyes exhibiting MA (42 patients with age-related macular degeneration), with a dry macula, underwent fundus autofluorescence and optical coherence tomography angiography. The area of MA detected by fundus autofluorescence and CC nonperfusion detected by optical coherence tomography angiography was measured using image analysis software. The rates of concordance between the MA and CC nonperfusion areas were calculated. We qualitatively and quantitatively compared the areas of MA and CC nonperfusion in age-related macular degeneration eyes. The mean areas of MA and CC nonperfusion were 5.95 ± 4.50 mm and 10.66 ± 7.05 mm, respectively (paired t-test, P autofluorescence matching optical coherence tomography angiography showed that the CC nonperfusion area was almost included in the MA area. The mean concordance rate for the MA area inside the CC nonperfusion area was 87.7 ± 13.9%. The MA and CC nonperfusion areas markedly overlapped. The area of CC nonperfusion correlated with the MA area. Choroidal ischemia might be involved in the pathogenesis of MA in treated age-related macular degeneration.This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  13. Inferior oblique weakening surgery on ocular torsion in congenital superior oblique palsy

    Directory of Open Access Journals (Sweden)

    Jinho Lee

    2015-06-01

    Full Text Available AIM:To investigate changes in fundus excyclotorsion after inferior oblique myectomy or myotomy.METHODS:The records of 21 patients undergoing strabismus surgery by a single surgeon between 2009 and 2012 were examined. Only patients who had undergone an inferior oblique myectomy or myotomy, with or without horizontal rectus muscle surgery, were evaluated. Digital fundus photographs were obtained, and the angle formed by a horizontal line passing through the optic disc center and a reference line connecting the foveola and optic disc center was measured. Associated clinical factors examined include age at the time of surgery, presence or absence of a head tilt, degree of preoperative vertical deviation, torsional angle, inferior oblique muscle overaction/superior oblique muscle underaction, and surgery laterality. Whether the procedure was performed alone or in combination with a horizontal rectus muscle surgery was also examined.RESULTS:Mean preoperative torsional angle was 12.0±6.4°, which decreased to 6.9±5.7° after surgery (P<0.001, paired t-test. Torsional angle also decreased from 15.1±7.0° to 6.2±4.3° in the myectomy group (P<0.001, paired t-test but there were no significant changes in the myotomy group (P=0.093, Wilcoxon signed rank test. Multivariable linear regression analysis showed that preoperative torsional angle, degree of inferior oblique overaction, and age at surgery independently and significantly affected postoperative torsional angle.CONCLUSION:Mean torsional angle decreased after inferior oblique myectomy. Degree of preoperative torsional angle, inferior oblique overaction, and age at surgery influence postoperative torsional angle.

  14. A Probabilistic Framework for Content-Based Diagnosis of Retinal Disease

    Energy Technology Data Exchange (ETDEWEB)

    Tobin Jr, Kenneth William [ORNL; Abdelrahman, Mohamed A [ORNL; Chaum, Edward [ORNL; Muthusamy Govindasamy, Vijaya Priya [ORNL; Karnowski, Thomas Paul [ORNL

    2007-01-01

    Diabetic retinopathy is the leading cause of blindness in the working age population around the world. Computer assisted analysis has the potential to assist in the early detection of diabetes by regular screening of large populations. The widespread availability of digital fundus cameras today is resulting in the accumulation of large image archives of diagnosed patient data that captures historical knowledge of retinal pathology. Through this research we are developing a content-based image retrieval method to verify our hypothesis that retinal pathology can be identified and quantified from visually similar retinal images in an image archive. We will present diagnostic results for specificity and sensitivity on a population of 395 fundus images representing the normal fundus and 14 stratified disease states.

  15. Clinical relevance of quantified fundus autofluorescence in diabetic macular oedema.

    Science.gov (United States)

    Yoshitake, S; Murakami, T; Uji, A; Unoki, N; Dodo, Y; Horii, T; Yoshimura, N

    2015-05-01

    To quantify the signal intensity of fundus autofluorescence (FAF) and evaluate its association with visual function and optical coherence tomography (OCT) findings in diabetic macular oedema (DMO). We reviewed 103 eyes of 78 patients with DMO and 30 eyes of 22 patients without DMO. FAF images were acquired using Heidelberg Retina Angiograph 2, and the signal levels of FAF in the individual subfields of the Early Treatment Diabetic Retinopathy Study grid were measured. We evaluated the association between quantified FAF and the logMAR VA and OCT findings. One hundred and three eyes with DMO had lower FAF signal intensity levels in the parafoveal subfields compared with 30 eyes without DMO. The autofluorescence intensity in the parafoveal subfields was associated negatively with logMAR VA and the retinal thickness in the corresponding subfields. The autofluorescence levels in the parafoveal subfield, except the nasal subfield, were lower in eyes with autofluorescent cystoid spaces in the corresponding subfield than in those without autofluorescent cystoid spaces. The autofluorescence level in the central subfield was related to foveal cystoid spaces but not logMAR VA or retinal thickness in the corresponding area. Quantified FAF in the parafovea has diagnostic significance and is clinically relevant in DMO.

  16. Fundus Autofluorescence and Spectral Domain OCT in Central Serous Chorioretinopathy

    Directory of Open Access Journals (Sweden)

    Luiz Roisman

    2011-01-01

    Full Text Available Background. To describe the standard autofluorescence (FAF, the near infrared autofluorescence (NIA and optical coherence tomography (OCT patterns in central serous chorioretinopathy, correlating them with fluorescein angiography. Methods. Cross-sectional observational study, in which patients with at least seven months of CSC underwent ophthalmologic examination, fundus photography, FAF, NIA, fluorescein angiography (FA, and spectral-domain OCT. Results. Seventeen eyes of thirteen patients were included. The presentation features were a mottled hyperFAF in the detached area and areas with pigment mottling. NIA images showed areas of hyperNIA similar to FAF and localized areas of hypoNIA, which correlated with the points of leakage in the FA. OCT showed pigment epithelium detachment at the location of these hypoNIA spots. Discussion. FAF showed increased presence of fluorophores in the area of retinal detachment, which is believed to appear secondary to lipofuscin accumulation in the RPE or the presence of debris in the subretinal fluid. NIA has been related to the choroidal melanin content and there were areas of both increased and decreased NIA, which could be explained by damage ahead the retina, basically RPE and choroid. These findings, along with the PEDs found in the areas of hypoNIA, support the notion of a primary choroidal disease in CSC.

  17. Digital Collections, Digital Libraries & the Digitization of Cultural Heritage Information.

    Science.gov (United States)

    Lynch, Clifford

    2002-01-01

    Discusses digital collections and digital libraries. Topics include broadband availability; digital rights protection; content, both non-profit and commercial; digitization of cultural content; sustainability; metadata harvesting protocol; infrastructure; authorship; linking multiple resources; data mining; digitization of reference works;…

  18. H. Sapiens Digital: From Digital Immigrants and Digital Natives to Digital Wisdom

    Science.gov (United States)

    Prensky, Marc

    2009-01-01

    As we move further into the 21st century, the digital native/digital immigrant paradigm created by Marc Prensky in 2001 is becoming less relevant. In this article, Prensky suggests that we should focus instead on the development of what he calls "digital wisdom." Arguing that digital technology can make us not just smarter but truly wiser, Prensky…

  19. Digital photogrammetry and histomorphometric assessment of the effect of non-coherent light (light-emitting diode) therapy (λ640 ± 20 nm) on the repair of third-degree burns in rats.

    Science.gov (United States)

    Neves, Silvana Maria Véras; Nicolau, Renata Amadei; Filho, Antônio Luiz Martins Maia; Mendes, Lianna Martha Soares; Veloso, Ana Maria

    2014-01-01

    Recent studies have demonstrated the efficacy of coherent light therapy from the red region of the electromagnetic spectrum on the tissue-healing process. This study analysed the effect of non-coherent light therapy (light-emitting diode-LED) with or without silver sulfadiazine (sulpha) on the healing process of third-degree burns. In this study, 72 rats with third-degree burns were randomly divided into six groups (n = 12): Gr1 (control), Gr2 (non-contact LED), Gr3 (contact LED), Gr4 (sulfadiazine), Gr5 (sulfadiazine + non-contact LED) and Gr6 (sulfadiazine + contact LED). The groups treated with LED therapy received treatment every 48 h (λ = 640 ± 20 nm, 110 mW, 16 J/cm(2); 41 s with contact and 680 s without contact). The digital photometric and histomorphometric analyses were conducted after the burn occurred. The combination of sulpha and LED (contact or non-contact) improved the healing of burn wounds. These results demonstrate that the combination of silver sulfadiazine with LED therapy (λ = 640 ± 20 nm, 4 J/cm(2), without contact) improves healing of third-degree burn wounds, significantly reduces the lesion area and increases the granulation tissue, increases the number of fibroblasts, promotes collagen synthesis and prevents burn infections by accelerating recovery.

  20. Digital Collections, Digital Libraries and the Digitization of Cultural Heritage Information.

    Science.gov (United States)

    Lynch, Clifford

    2002-01-01

    Discusses the development of digital collections and digital libraries. Topics include digitization of cultural heritage information; broadband issues; lack of compelling content; training issues; types of materials being digitized; sustainability; digital preservation; infrastructure; digital images; data mining; and future possibilities for…

  1. Multimodal Ultrawide-Field Imaging Features in Waardenburg Syndrome.

    Science.gov (United States)

    Choudhry, Netan; Rao, Rajesh C

    2015-06-01

    A 45-year-old woman was referred for bilateral irregular fundus pigmentation. Dilated fundus examination revealed irregular hypopigmentation posterior to the equator in both eyes, confirmed by fundus autofluorescence. A thickened choroid was seen on enhanced-depth imaging spectral-domain optical coherence tomography (EDI SD-OCT). Systemic evaluation revealed sensorineural deafness, telecanthus, and a white forelock. Further investigation revealed a first-degree relative with Waardenburg syndrome. Waardenburg syndrome is characterized by a group of features including telecanthus, a broad nasal root, synophrys of the eyebrows, piedbaldism, heterochromia irides, and deafness. Choroidal hypopigmentation is a unique feature that can be visualized with ultrawide-field fundus autofluorescence. The choroid may also be thickened and its thickness measured with EDI SD-OCT. Copyright 2015, SLACK Incorporated.

  2. 眼底荧光造影检查对筛检糖尿病眼底病变的临床价值%Fundus Fluorescence Angiography Revealed the Clinical Value of Screening Diabetic Retinal Pathological Changes

    Institute of Scientific and Technical Information of China (English)

    王克

    2016-01-01

    Objective To explore the application value of fundus fluorescein angiography in screening of diabetic retinopa-thy. Methods Convenient selection who were admitted to our hospital in January 2013 to January 2016 By ophthalmoscopy and fundus fluorescence angiography 78 cases (156 eyes) in patients with diabetes mellitus retinopathy screening, according to Dr staging criteria for diagnosis of diabetic retinopathy staging, and thus as the foundation to give guidance of treatment. Results The detection rate of fundus fluorescein angiography in diabetic retinopathy (82.50%) was higher than that in the fundus examination (67.31%). The difference was statistically significant (P< 0.05). DR stage I period of 47 eyes (30.1%). II phase 29 eyes(18.6%), III phase 25 eyes(16%), IV phase 17 eyes(10.9%), V phase 7 eyes(4.5%), VI phase 3 eyes (1.9%). Conclusion The detection rate of fundus fluorescein angiography in diabetic retinopathy is high, which can be used as an important reference index to guide the treatment of ocular fundus diseases.%目的:探讨眼底荧光造影检查在糖尿病眼底病变筛查中的应用价值。方法方便选取2013年1月—2016年1月以眼底镜和眼底荧光造影检查该院收治的78例(156眼)糖尿病患者进行眼底病变筛查,依DR分期标准对筛查出的糖尿病视网膜病变进行分期,并以此为基础给予患者治疗指导。结果眼底荧光造影对糖尿病眼底病变的检出率显(82.50%)著高于眼底镜下检查(67.31%)。比较差异有统计学意义(P﹤0.05)。 DR分期I期47眼(30.1%)。 II期29眼(18.6%),III期25眼(16.0%),IV期17眼(10.9%),V期7眼(4.5%),VI期3眼(1.9%)。结论以眼底荧光造影筛查糖尿病眼底病变检出率高,可作为指导眼底病变治疗的重要参考指标在临床推广使用。

  3. Automated digital magnetofluidics

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, J; Garcia, A A; Marquez, M [Harrington Department of Bioengineering Arizona State University, Tempe AZ 85287-9709 (United States)], E-mail: tony.garcia@asu.edu

    2008-08-15

    Drops can be moved in complex patterns on superhydrophobic surfaces using a reconfigured computer-controlled x-y metrology stage with a high degree of accuracy, flexibility, and reconfigurability. The stage employs a DMC-4030 controller which has a RISC-based, clock multiplying processor with DSP functions, accepting encoder inputs up to 22 MHz, provides servo update rates as high as 32 kHz, and processes commands at rates as fast as 40 milliseconds. A 6.35 mm diameter cylindrical NdFeB magnet is translated by the stage causing water drops to move by the action of induced magnetization of coated iron microspheres that remain in the drop and are attracted to the rare earth magnet through digital magnetofluidics. Water drops are easily moved in complex patterns in automated digital magnetofluidics at an average speed of 2.8 cm/s over a superhydrophobic polyethylene surface created by solvent casting. With additional components, some potential uses for this automated microfluidic system include characterization of superhydrophobic surfaces, water quality analysis, and medical diagnostics.

  4. Automated digital magnetofluidics

    Science.gov (United States)

    Schneider, J.; Garcia, A. A.; Marquez, M.

    2008-08-01

    Drops can be moved in complex patterns on superhydrophobic surfaces using a reconfigured computer-controlled x-y metrology stage with a high degree of accuracy, flexibility, and reconfigurability. The stage employs a DMC-4030 controller which has a RISC-based, clock multiplying processor with DSP functions, accepting encoder inputs up to 22 MHz, provides servo update rates as high as 32 kHz, and processes commands at rates as fast as 40 milliseconds. A 6.35 mm diameter cylindrical NdFeB magnet is translated by the stage causing water drops to move by the action of induced magnetization of coated iron microspheres that remain in the drop and are attracted to the rare earth magnet through digital magnetofluidics. Water drops are easily moved in complex patterns in automated digital magnetofluidics at an average speed of 2.8 cm/s over a superhydrophobic polyethylene surface created by solvent casting. With additional components, some potential uses for this automated microfluidic system include characterization of superhydrophobic surfaces, water quality analysis, and medical diagnostics.

  5. Digital image processing for radiography in nuclear power plants

    International Nuclear Information System (INIS)

    Heidt, H.; Rose, P.; Raabe, P.; Daum, W.

    1985-01-01

    With the help of digital processing of radiographic images from reactor-components it is possible to increase the security and objectiveness of the evaluation. Several examples of image processing procedures (contrast enhancement, density profiles, shading correction, digital filtering, superposition of images etc.) show the advantages for the visualization and evaluation of radiographs. Digital image processing can reduce some of the restrictions of radiography in nuclear power plants. In addition a higher degree of automation can be cost-saving and increase the quality of radiographic evaluation. The aim of the work performed was to to improve the readability of radiographs for the human observer. The main problem is lack of contrast and the presence of disturbing structures like weld seams. Digital image processing of film radiographs starts with the digitization of the image. Conventional systems use TV-cameras or scanners and provide a dynamic range of 1.5. to 3 density units, which are digitized to 256 grey levels. For the enhancement process it is necessary that the grey level range covers the density range of the important regions of the presented film. On the other hand the grey level coverage should not be wider than necessary to minimize the width of digitization steps. Poor digitization makes flaws and cracks invisible and spoils all further image processing

  6. EVALUATION OF DIABETIC MACULAR OEDEMA WITH SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY AND FUNDUS FLUORESCEIN ANGIOGRAPHY

    Directory of Open Access Journals (Sweden)

    Mallika Venkitasubramanian

    2017-02-01

    Full Text Available BACKGROUND Macular oedema is an important cause of visual morbidity in Diabetic Retinopathy. It can be assessed by both Fundus Fluorescein Angiography (FFA and Optical Coherence Tomography (OCT. The aims of this study were to evaluate the agreement between morphological features on spectral domain Optical Coherence Tomography and Fluorescein Angiographic leakage patterns in Diabetic Macular Oedema, and to study the correlation between the best corrected visual acuity and central foveal thickness measured by Optical Coherence Tomography. MATERIALS AND METHODS This was an observational study. All patients with Diabetic Macular Oedema underwent complete ophthalmic examination and subjected to FFA and OCT. Presence or absence of macular oedema by FFA and OCT was noted and agreement between two modalities of imaging was assessed. Sensitivity of these modalities were also found out using appropriate statistical methods. Best Corrected Visual Acuity (BCVA measured were converted to LogMAR scale and Central foveal thickness measured by OCT. Linear regression analysis was done with central foveal thickness and LogMAR visual acuity. RESULTS A total of 69 eyes of 39 patients were studied. OCT revealed Diabetic Macular Oedema in 97.5% of eyes. Fundus Fluorescein Angiography performed in these patients identified leakage in 95.6% of eyes. Sensitivity and specificity of FFA and OCT were calculated keeping one as the gold standard for sensitivity and specificity of the other. FFA and OCT had almost equal sensitivity (95.46 for OCT and 96.92 for FFA for detection of DME. Specificity of OCT was found to be slightly higher (33.33% compared to FFA (25%. Our results suggest that there is minimal agreement between these two imaging modalities in evaluating DME. Statistically, Kappa value was 0.248. Linear regression analysis showed that central foveal thickness had a significant correlation with visual acuity, with Pearson correlation coefficient r=0.442, p=0

  7. Automatic Diabetic Macular Edema Detection in Fundus Images Using Publicly Available Datasets

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Meriaudeau, Fabrice [ORNL; Karnowski, Thomas Paul [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK); Garg, Seema [University of North Carolina; Tobin Jr, Kenneth William [ORNL; Chaum, Edward [University of Tennessee, Knoxville (UTK)

    2011-01-01

    Diabetic macular edema (DME) is a common vision threatening complication of diabetic retinopathy. In a large scale screening environment DME can be assessed by detecting exudates (a type of bright lesions) in fundus images. In this work, we introduce a new methodology for diagnosis of DME using a novel set of features based on colour, wavelet decomposition and automatic lesion segmentation. These features are employed to train a classifier able to automatically diagnose DME. We present a new publicly available dataset with ground-truth data containing 169 patients from various ethnic groups and levels of DME. This and other two publicly available datasets are employed to evaluate our algorithm. We are able to achieve diagnosis performance comparable to retina experts on the MESSIDOR (an independently labelled dataset with 1200 images) with cross-dataset testing. Our algorithm is robust to segmentation uncertainties, does not need ground truth at lesion level, and is very fast, generating a diagnosis on an average of 4.4 seconds per image on an 2.6 GHz platform with an unoptimised Matlab implementation.

  8. Transforming students into digital academics

    DEFF Research Database (Denmark)

    Thorell, Maria; Fridorff-Jens, Peter Kindt; Lassen, Pia

    2015-01-01

    BACKGROUND: Little is known of students' Information and Communication Technology (ICT) readiness in a learning context. Information about students' capabilities and resources is an important prerequisite for designing meaningful teaching and learning activities that engage and motivate students....... To learn about health science students' usage of digital equipment, familiarity with software, online behavior and communication with the university, we have conducted a survey focusing on these areas. METHODS: A digital questionnaire was sent to 9134 health science students, of whom 1165 responded (12...... of chat users was 23.8 (Standard deviation 3.7) years, SMS users, 25 (Standard deviation 4.2) years and email users, 27.9 (Standard deviation 6.5) years. Over half of the students (53.4%) found that the degree of ICT incorporated in the teaching and learning activities was insufficient to provide them...

  9. Robustness of digital artist authentication

    DEFF Research Database (Denmark)

    Jacobsen, Robert; Nielsen, Morten

    In many cases it is possible to determine the authenticity of a painting from digital reproductions of the paintings; this has been demonstrated for a variety of artists and with different approaches. Common to all these methods in digital artist authentication is that the potential of the method...... is in focus, while the robustness has not been considered, i.e. the degree to which the data collection process influences the decision of the method. However, in order for an authentication method to be successful in practice, it needs to be robust to plausible error sources from the data collection....... In this paper we investigate the robustness of the newly proposed authenticity method introduced by the authors based on second generation multiresolution analysis. This is done by modelling a number of realistic factors that can occur in the data collection....

  10. Digital Humanities and networked digital media

    DEFF Research Database (Denmark)

    Finnemann, Niels Ole

    2014-01-01

    This article discusses digital humanities and the growing diversity of digital media, digital materials and digital methods. The first section describes the humanities computing tradition formed around the interpretation of computation as a rule-based process connected to a concept of digital...... materials centred on the digitisation of non-digital, finite works, corpora and oeuvres. The second section discusses “the big tent” of contemporary digital humanities. It is argued that there can be no unifying interpretation of digital humanities above the level of studying digital materials with the help...... of software-supported methods. This is so, in part, because of the complexity of the world and, in part, because digital media remain open to the projection of new epistemologies onto the functional architecture of these media. The third section discusses the heterogeneous character of digital materials...

  11. Kopernik : modeling business processes for digital customers

    OpenAIRE

    Estañol Lamarca, Montserrat; Castro, Manuel; Díaz-Montenegro, Sylvia; Teniente López, Ernest

    2016-01-01

    This paper presents the Kopernik methodology for modeling business processes for digital customers. These processes require a high degree of flexibility in the execution of their tasks or actions. We achieve this by using the artifact-centric approach to process modeling and the use of condition-action rules. The processes modeled following Kopernik can then be implemented in an existing commercial tool, Balandra.

  12. Optimization of multiwire coil ends having 45 degree bends

    International Nuclear Information System (INIS)

    Morgan, G.H.

    1989-01-01

    Multiwire is the name of a proprietary process for affixing small diameter wires to a flat substrate using digitally controlled machinery. It is currently being used to wind trim coils for the SSC dipoles on a flexible substrate which is wrapped around the beam tube. It is proposed for making multipole coils for the Corrector, a regular arc magnet in each half-cell of the Relativistic Heavy Ion Collider (RHIC). The current Multiwire process does not permit a change in direction of the wire other than 45 degree. The present paper answers the question of whether the 45 degree bends in the flattened coil can be located along straight lines in such a way as to eliminate or reduce higher harmonics in the ends. The more general question of bends located along curves is not addressed

  13. Optimization of multiwire coil ends having 45 degree bends

    International Nuclear Information System (INIS)

    Morgan, G.H.

    1988-01-01

    Multiwire is the name of a proprietary process for affixing small diameter wires to a flat substrate using digitally controlled machinery. It is currently being used to wind trim coils for the SSC dipoles on a flexible substrate which is wrapped around the beam tube. It is proposed for making multipole coils for the Corrector, a regular arc magnet in each half-cell of the Relativistic Heavy Ion Collider (RHIC). The current Multiwire process does not permit a change in direction of the wire other than 45 degree. The present paper answers the question of whether the 45 degree bends in the flattened coil can be located along straight lines in such a way as to eliminate or reduce higher harmonics in the ends. The more general question of bends located along curves is not addressed. 3 refs., 3 figs., 2 tabs

  14. Preferred retinal locus in macular disease: characteristics and clinical implications.

    Science.gov (United States)

    Greenstein, Vivienne C; Santos, Rodrigo A V; Tsang, Stephen H; Smith, R Theodore; Barile, Gaetano R; Seiple, William

    2008-10-01

    To investigate the location and fixation stability of preferred retinal locations (PRLs) in patients with macular disease, and the relationship among areas of abnormal fundus autofluorescence, the PRL and visual sensitivity. Fifteen patients (15 eyes) were studied. Seven had Stargardt disease, 1 bull's eye maculopathy, 5 age-related macular degeneration, 1 Best disease, and 1 pattern dystrophy. All tested eyes had areas of abnormal fundus autofluorescence. The PRL was evaluated with fundus photography and the Nidek microperimeter. Visual field sensitivity was measured with the Nidek microperimeter. Of the 15 eyes, 4 had foveal and 11 had eccentric fixation. Eccentric PRLs were above the atrophic lesion and their stability did not depend on the degree of eccentricity from the fovea. Visual sensitivity was markedly decreased in locations corresponding to hypofluorescent areas. Sensitivity was not decreased in hyperfluorescent areas corresponding to flecks but was decreased if hyperfluorescence was in the form of dense annuli. Eccentric PRLs were in the superior retina in regions of normal fundus autofluorescence. Fixation stability was not correlated with the degree of eccentricity from the fovea. To assess the outcomes of treatment trials it is important to use methods that relate retinal morphology to visual function.

  15. Measurement of digital blood pressure after local cooling

    DEFF Research Database (Denmark)

    Nielsen, S L; Lassen, N A

    1977-01-01

    A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between...... the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women...

  16. Spectrally resolved digital holography using a white light LED

    Science.gov (United States)

    Claus, D.; Pedrini, G.; Buchta, D.; Osten, W.

    2017-06-01

    This paper introduces the concept of spectrally resolved digital holography. The measurement principle and the analysis of the data will be discussed in detail. The usefulness of spectrally resolved digital holography is demonstrated for colour imaging and optical metrology with regards to the recovery of modulus information and phase information, respectively. The phase information will be used to measure the shape of an object via the application of the dual wavelength method. Based on the large degree of data available, multiple speckle de-correlated dual wavelength phase maps can be obtained, which when averaged result in a signal to noise ratio improvement.

  17. Exploration of the Visual System: Part 2: In Vivo Analysis Methods: Virtual-Reality Optomotor System, Fundus Examination, and Fluorescent Angiography.

    Science.gov (United States)

    Marcelli, Fabienne; Escher, Pascal; Schorderet, Daniel F

    2012-09-01

    The mouse has emerged as an animal model for many diseases. At IRO, we have used this animal to understand the development of many eye diseases and treatment of some of them. Precise evaluation of vision is a prerequisite for both these approaches. In this unit we describe three ways to measure vision: testing the optokinetic response, and evaluating the fundus by direct observation and by fluorescent angiography. Curr. Protoc. Mouse Biol. 2:207-218 © 2012 by John Wiley & Sons, Inc. Copyright © 2012 John Wiley & Sons, Inc.

  18. Mycophenolate mofetil combined with systemic corticosteroids prevents progression to chronic recurrent inflammation and development of 'sunset glow fundus' in initial-onset acute uveitis associated with Vogt-Koyanagi-Harada disease.

    Science.gov (United States)

    Abu El-Asrar, Ahmed M; Dosari, Mona; Hemachandran, Suhail; Gikandi, Priscilla W; Al-Muammar, Abdulrahman

    2017-02-01

    To evaluate the effectiveness and safety of mycophenolate mofetil (MMF) as first-line therapy combined with systemic corticosteroids in initial-onset acute uveitis associated with Vogt-Koyanagi-Harada (VKH) disease. This prospective study included 38 patients (76 eyes). The main outcome measures were final visual acuity, corticosteroid-sparing effect, progression to chronic recurrent granulomatous uveitis and development of complications, particularly 'sunset glow fundus'. The mean follow-up period was 37.0 ± 29.3 (range 9-120 months). Visual acuity of 20/20 was achieved by 93.4% of the eyes. Corticosteroid-sparing effect was achieved in all patients. The mean interval between starting treatment and tapering to 10 mg or less daily was 3.8 ± 1.3 months (range 3-7 months). Twenty-two patients (57.9%) discontinued treatment without relapse of inflammation. The mean time observed off of treatment was 28.1 ± 19.6 months (range 1-60 months). None of the eyes progressed to chronic recurrent granulomatous uveitis. The ocular complications encountered were glaucoma in two eyes (2.6%) and cataract in five eyes (6.6%). None of the eyes developed 'sunset glow fundus', and none of the patients developed any systemic adverse events associated with the treatment. Use of MMF as first-line therapy combined with systemic corticosteroids in patients with initial-onset acute VKH disease prevents progression to chronic recurrent granulomatous inflammation and development of 'sunset glow fundus'. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  19. Building Multi-Discipline, Multi-Format Digital Libraries Using Clusters and Buckets. Degree rewarded by Old Dominion Univ. on Aug. 1997

    Science.gov (United States)

    Nelson, Michael L.

    1997-01-01

    Our objective was to study the feasibility of extending the Dienst protocol to enable a multi-discipline, multi-format digital library. We implemented two new technologies: cluster functionality and publishing buckets. We have designed a possible implementation of clusters and buckets, and have prototyped some aspects of the resultant digital library. Currently, digital libraries are segregated by the disciplines they serve (computer science, aeronautics, etc.), and by the format of their holdings (reports, software, datasets, etc.). NCSTRL+ is a multi-discipline, multi-format digital library (DL) prototype created to explore the feasibility of the design and implementation issues involved with created a unified, canonical scientific and technical information (STI) DL. NCSTRL+ is based on the Networked Computer Science Technical Report Library (NCSTRL), a World Wide Web (WWW) accessible DL that provides access to over 80 university departments and laboratories. We have extended the Dienst protocol (version 4.1.8), the protocol underlying NCSTRL, to provide the ability to cluster independent collections into a logically centralized DL based upon subject category classification, type of organization, and genre of material. The concept of buckets provides a mechanism for publishing and managing logically linked entities with multiple data formats.

  20. Digital broadcasting

    International Nuclear Information System (INIS)

    Park, Ji Hyeong

    1999-06-01

    This book contains twelve chapters, which deals with digitization of broadcast signal such as digital open, digitization of video signal and sound signal digitization of broadcasting equipment like DTPP and digital VTR, digitization of equipment to transmit such as digital STL, digital FPU and digital SNG, digitization of transmit about digital TV transmit and radio transmit, digital broadcasting system on necessity and advantage, digital broadcasting system abroad and Korea, digital broadcasting of outline, advantage of digital TV, ripple effect of digital broadcasting and consideration of digital broadcasting, ground wave digital broadcasting of DVB-T in Europe DTV in U.S.A and ISDB-T in Japan, HDTV broadcasting, satellite broadcasting, digital TV broadcasting in Korea, digital radio broadcasting and new broadcasting service.

  1. Microaneurysms detection with the radon cliff operator in retinal fundus images

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Meriaudeau, Fabrice [ORNL; Karnowski, Thomas Paul [ORNL; Tobin Jr, Kenneth William [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK); Chaum, Edward [University of Tennessee, Knoxville (UTK)

    2010-01-01

    Diabetic Retinopathy (DR) is one of the leading causes of blindness in the industrialized world. Early detection is the key in providing effective treatment. However, the current number of trained eye care specialists is inadequate to screen the increasing number of diabetic patients. In recent years, automated and semi-automated systems to detect DR with color fundus images have been developed with encouraging, but not fully satisfactory results. In this study we present the initial results of a new technique for the detection and localization of microaneurysms, an early sign of DR. The algorithm is based on three steps: candidates selection, the actual microaneurysms detection and a final probability evaluation. We introduce the new Radon Cliff operator which is our main contribution to the field. Making use of the Radon transform, the operator is able to detect single noisy Gaussian-like circular structures regardless of their size or strength. The advantages over existing microaneurysms detectors are manifold: the size of the lesions can be unknown, it automatically distinguishes lesions from the vasculature and it provides a fair approach to microaneurysm localization even without post-processing the candidates with machine learning techniques, facilitating the training phase. The algorithm is evaluated on a publicly available dataset from the Retinopathy Online Challenge.

  2. Microaneurysms detection with the radon cliff operator in retinal fundus images

    Science.gov (United States)

    Giancardo, Luca; Mériaudeau, Fabrice; Karnowski, Thomas P.; Tobin, Kenneth W.; Li, Yaqin; Chaum, Edward

    2010-03-01

    Diabetic Retinopathy (DR) is one of the leading causes of blindness in the industrialized world. Early detection is the key in providing effective treatment. However, the current number of trained eye care specialists is inadequate to screen the increasing number of diabetic patients. In recent years, automated and semi-automated systems to detect DR with color fundus images have been developed with encouraging, but not fully satisfactory results. In this study we present the initial results of a new technique for the detection and localization of microaneurysms, an early sign of DR. The algorithm is based on three steps: candidates selection, the actual microaneurysms detection and a final probability evaluation. We introduce the new Radon Cliff operator which is our main contribution to the field. Making use of the Radon transform, the operator is able to detect single noisy Gaussian-like circular structures regardless of their size or strength. The advantages over existing microaneurysms detectors are manifold: the size of the lesions can be unknown, it automatically distinguishes lesions from the vasculature and it provides a fair approach to microaneurysm localization even without post-processing the candidates with machine learning techniques, facilitating the training phase. The algorithm is evaluated on a publicly available dataset from the Retinopathy Online Challenge.

  3. Effect of chronic aspirin ingestion on epithelial proliferation in rat fundus, antrum, and duodenum

    International Nuclear Information System (INIS)

    Eastwood, G.L.; Quimby, G.F.

    1972-01-01

    We studied the effect of chronic aspirin ingestion on gastroduodenal epithelial proliferation by feeding rats aspirin in the drinking water. A control group of rats received plain water. At the end of 4 wk, [3H]-thymidine was given intravenously to label proliferating cells, and the rats were killed 1 h later. Sections of fundus, antrum, and proximal duodenum were processed for light autoradiography. We found that chronic aspirin ingestion stimulated epithelial proliferation in fundic mucosa but had no effect in the antrum. In the duodenum, aspirin increased proliferation in the lowest four crypt-cell positions, which most likely indicates an increase in stem-cell production. None of the tissues contained evidence of inflammation or ulceration. The proliferative effects of aspirin may help explain the previously observed phenomenon of mucosal adaptation in the rat after repeated exposure to aspirin. Further, if human gastroduodenal epithelium responds in a similar manner to chronic aspirin exposure, the effects on proliferation may explain in part the distribution of aspirin-associated ulcers

  4. Fundus Autofluorescence and Optical Coherence Tomography Findings in Branch Retinal Vein Occlusion

    Directory of Open Access Journals (Sweden)

    Tetsuju Sekiryu

    2012-01-01

    Full Text Available Purpose. To describe the findings of fundus autofluorescence (FAF and optical coherence tomography (OCT in patients with branch retinal vein occlusion (BRVO. Methods. In this institutional, retrospective, observational case series, FAF was evaluated in 65 eyes with BRVO in 64 consecutive patients and compared with visual acuity, OCT findings, and other clinical observations. Results. Five types of autofluorescence appeared during the course of BRVO: (1 petaloid-shaped hyperautofluorescence in the area of macular edema and (2 hyperautofluorescence coincident with yellow subretinal deposits. (3 Diffuse hyperautofluorescence appeared within the area of serous retinal detachment (SRD and OCT showed precipitates on the undersurface of the retina in 5/5 of these eyes (100%. (4 The area of vein occlusion showed diffuse hyperautofluorescence after resolution of the retinal bleeding. (5 Hard exudates exhibited hyper- or hypoautofluorescence. OCT indicated that most of the hard exudates with hyperautofluorescence were located on the retinal pigment epithelium. Conclusions. Hyperautofluorescence associated with subretinal fluid or hard exudate appeared in the subretinal space. This type of hyperautofluorescence may be attributed to blood cell or macrophages. FAF and OCT are noninvasive modalities that provide additional information regarding macular edema due to BRVO.

  5. [The digital reprocessing of under- and overexposed x-ray films with a personal computer].

    Science.gov (United States)

    Fuhrmann, R; Diedrich, P

    1993-02-01

    An image processing work station for digitalizing and interactively manipulating under- and overexposed X-rays was set up by adding modules to an IBM compatible personal computer. Overexposed X-rays can be qualitatively enhanced by means of controlled manipulation of contrast and brightness and by means of the use of various digital filtering techniques. With underexposed X-rays an equalized grey scale can be achieved by means of regulating contrast and brightness. Digital filtering is not required. To assure a high degree of anatomical detail (periodontal ligament) in the digitalized image a maximum pixel of 0.1 mm was defined as a qualitative norm. Since in every digitalization process resolution is diminished, it proved best to select for interactive manipulation out of the total image only the section of interest.

  6. Automatic Detection of Diabetic Retinopathy in Digital Fundus Photographs

    NARCIS (Netherlands)

    Niemeijer, M.

    2006-01-01

    Diabetic retinopathy is a common ocular complication of diabetes. It is the most frequent cause of blindness in the working population of the United States and the European Union. Early diagnosis, and treatment can prevent vision loss in the majority of cases. Yet only approximately 50% of people

  7. Development of a digital impression procedure using photogrammetry for complete denture fabrication.

    Science.gov (United States)

    Matsuda, Takashi; Goto, Takaharu; Kurahashi, Kosuke; Kashiwabara, Toshiya; Ichikawa, Tetsuo

    We developed an innovative procedure for digitizing maxillary edentulous residual ridges with a photogrammetric system capable of estimating three-dimensional (3D) digital forms from multiple two-dimensional (2D) digital images. The aim of this study was to validate the effectiveness of the photogrammetric system. Impressions of the maxillary residual ridges of five edentulous patients were taken with four kinds of procedures: three conventional impression procedures and the photogrammetric system. Plaster models were fabricated from conventional impressions and digitized with a 3D scanner. Two 3D forms out of four forms were superimposed with 3D inspection software, and differences were evaluated using a least squares best fit algorithm. The in vitro experiment suggested that better imaging conditions were in the horizontal range of ± 15 degrees and at a vertical angle of 45 degrees. The mean difference between the photogrammetric image (Form A) and the image taken from conventional preliminarily impression (Form C) was 0.52 ± 0.22 mm. The mean difference between the image taken of final impression through a special tray (Form B) and Form C was 0.26 ± 0.06 mm. The mean difference between the image taken from conventional final impression (Form D) and Form C was 0.25 ± 0.07 mm. The difference between Forms A and C was significantly larger than the differences between Forms B and C and between Forms D and C. The results of this study suggest that obtaining digital impressions of edentulous residual ridges using a photogrammetric system is feasible and available for clinical use.

  8. Configurable Analog-Digital Conversion Using the Neural EngineeringFramework

    Directory of Open Access Journals (Sweden)

    Christian G Mayr

    2014-07-01

    Full Text Available Efficient Analog-Digital Converters (ADC are one of the mainstays of mixed-signal integrated circuit design. Besides the conventional ADCs used in mainstream ICs, there have been various attempts in the past to utilize neuromorphic networks to accomplish an efficient crossing between analog and digital domains, i.e. to build neurally inspired ADCs. Generally, these have suffered from the same problems as conventional ADCs, that is they require high-precision, handcrafted analog circuits and are thus not technology portable. In this paper, we present an ADC based on the Neural Engineering Framework (NEF. It carries out a large fraction of the overall ADC process in the digital domain, i.e. it is easily portable across technologies. The analog-digital conversion takes full advantage of the high degree of parallelism inherent in neuromorphic networks, making for a very scalable ADC. In addition, it has a number of features not commonly found in conventional ADCs, such as a runtime reconfigurability of the ADC sampling rate, resolution and transfer characteristic.

  9. Comparative study between fundus autofluorescence and red reflectance imaging of choroidal nevi using ultra-wide-field scanning laser ophthalmoscopy.

    Science.gov (United States)

    Zapata, Miguel Angel; Leila, Mahmoud; Teixidor, Teresa; Garcia-Arumi, Jose

    2015-06-01

    To explore the utility of fundus autofluorescence (FAF) and red reflectance (RR) imaging using ultra-wide-field scanning laser ophthalmoscope in choroidal nevi. Retrospective observational case study reviewing clinical data, color, FAF, and RR images of patients with choroidal nevi and comparing the findings. The ultra-wide-field scanning laser ophthalmoscope uses green laser 532 nm and red laser 633 nm that enabled FAF and RR imaging, respectively in separate channels. Superimposition of both images yielded a composite color image. The study included 46 eyes of 45 patients. Nevi were unilateral in 44 patients (98%). Forty-one nevi (89.1%) were located temporally between the macula and the equator. All nevi (100%) were deeply pigmented. The most frequent surface changes were lipofuscin pigments, zones of retinal pigment epithelium atrophy, and retinal pigment epithelium pigment clumps in 31 (67.3%), 18 (39.1%), and 8 eyes (17.3%), respectively. Color photographs were superior to FAF in detecting nevus boundaries and surface changes. Red reflectance correlated strongly with color images, although the nevus boundaries and surface changes were better delineated in RR mode. Red reflectance was superior to FAF in delineating the boundaries and surface changes of the nevus; clear visibility (3+) for RR versus no or poor visibility (0/1+) for FAF. Nevertheless, the areas of retinal pigment epithelium atrophy were better delineated in FAF mode; clear visibility (3+) for FAF versus poor visibility (1+) for FAF. Red reflectance imaging is more sensitive than conventional photography for follow-up of choroidal nevi. Fundus autofluorescence should be considered only as a complementary tool to RR imaging.

  10. Standard digital reference images for inspection of aluminum castings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These digital reference images illustrate the types and degrees of discontinuities that may be found in aluminum-alloy castings. The castings illustrated are in thicknesses of 1/ 4 in. [6.35 mm] and 3/4 in. [19.1mm]. 1.2 All areas of this standard may be open to agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizant engineering organization. These items should be addressed in the purchase order or the contract. 1.3 The values stated in inch-pound units are to be regarded as standard. 1.4 These digital reference images are not intended to illustrate the types and degrees of discontinuities found in aluminum-alloy castings when performing film radiography. If performing film radiography of aluminum-alloy castings, refer to Reference Radiographs E 155. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and he...

  11. Diabetic Retinopathy Screening Using Telemedicine Tools: Pilot Study in Hungary

    Directory of Open Access Journals (Sweden)

    Dóra J. Eszes

    2016-01-01

    Full Text Available Introduction. Diabetic retinopathy (DR is a sight-threatening complication of diabetes. Telemedicine tools can prevent blindness. We aimed to investigate the patients’ satisfaction when using such tools (fundus camera examination and the effect of demographic and socioeconomic factors on participation in screening. Methods. Pilot study involving fundus camera screening and self-administered questionnaire on participants’ experience during fundus examination (comfort, reliability, and future interest in participation, as well as demographic and socioeconomic factors was performed on 89 patients with known diabetes in Csongrád County, a southeastern region of Hungary. Results. Thirty percent of the patients had never participated in any ophthalmological screening, while 25.7% had DR of some grade based upon a standard fundus camera examination and UK-based DR grading protocol (Spectra™ software. Large majority of the patients were satisfied with the screening and found it reliable and acceptable to undertake examination under pupil dilation; 67.3% were willing to undergo nonmydriatic fundus camera examination again. There was a statistically significant relationship between economic activity, education and marital status, and future interest in participation. Discussion. Participants found digital retinal screening to be reliable and satisfactory. Telemedicine can be a strong tool, supporting eye care professionals and allowing for faster and more comfortable DR screening.

  12. Sub-picosecond Resolution Time-to-Digital Converter

    Energy Technology Data Exchange (ETDEWEB)

    Bratov, Vladimir [Advanced Science and Novel Technology Company, Rancho Palos Verdes, CA (United States); Katzman, Vladimir [Advanced Science and Novel Technology Company, Rancho Palos Verdes, CA (United States); Binkley, Jeb [Advanced Science and Novel Technology Company, Rancho Palos Verdes, CA (United States)

    2006-03-30

    Time-to-digital converters with sub-picosecond resolutions are needed to satisfy the requirements of time-on-flight measurements of the next generation of high energy and nuclear physics experiments. The converters must be highly integrated, power effective, low cost, and feature plug-and-play capabilities to handle the increasing number of channels (up to hundreds of millions) in future Department of Energy experiments. Current state-off-the-art time-to-digital converter integrated circuits do not have the sufficient degree of integration and flexibility to fulfill all the described requirements. During Phase I, the Advanced Science and Novel Technology Company in cooperation with the nuclear physics division of the Oak Ridge National Laboratory has developed the architecture of a novel time-to-digital converter with multiple channels connected to an external processor through a special interfacing block and synchronized by clock signals generated by an internal phase-locked loop. The critical blocks of the system including signal delay lines and delay-locked loops with proprietary differential delay cells, as well as the required digital code converter and the clock period counter have been designed and simulated using the advanced SiGe120 BiCMOS technological process. The results of investigations demonstrate a possibility to achieve the digitization accuracy within 1ps. ADSANTEC has demonstrated the feasibility of the proposed concept in computer simulations. The proposed system will be a critical component for the next generation of NEP experiments.

  13. PERSEPSI GURU TENTANG DIGITAL NATIVES, SUMBER BELAJAR DIGITAL DAN MOTIVASI MEMANFAATKAN SUMBER BELAJAR DIGITAL

    Directory of Open Access Journals (Sweden)

    Ferdinandus Bate Dopo

    2016-06-01

    TEACHER’S PERCEPTION OF DIGITAL NATIVES, DIGITAL LEARNING RESOURCES AND MOTIVATION TO UTILIZE DIGITAL LEARNING RESOURCES Abstract This study aims to reveal (1 the influence of teacher's perception of digital natives toward teacher’s motivation to utilize digital learning resources. (2 the influence of teacher's perception of digital learning resources toward teacher’s motivation to utilize digital learning resources and (3 the influence both of teacher's perception of digital natives and digital learning resources toward teacher’s motivation to utilize digital learning resources. This study used the descriptive-correlational quantitative approach. The Population and sample were high school teachers of Regina Pacis Bajawa, SMA Seminari Mataloko and SMA Negeri 1 Golewa. Sampling technique in this research was proportional random sampling. A questionnaire was used to obtain the data. The data were analyzed using the Likert scale. The instrument was developed based on lattice theory of assessment instruments relevant to the study variables. The analysis technique used is a regression followed by statistic technique of t test and F test with the significance level of 0.05. The results are as follows. (1 There is a positive and significant influence of teacher's perception of digital natives toward teacher’s motivation to utilize digital learning resources. (2 There is a positive and significant influence of teacher's perception of digital learning resources and teacher’s motivation to utilize digital learning resources. (3 There is a positive and significant influence both of teacher's perception of digital learning resources and teacher’s motivation to utilize digital learning resources. Keywords: perception, digital natives, digital learning resources, motivation

  14. The Diabetic Retinopathy Screening Workflow

    Science.gov (United States)

    Bolster, Nigel M.; Giardini, Mario E.; Bastawrous, Andrew

    2015-01-01

    Complications of diabetes mellitus, namely diabetic retinopathy and diabetic maculopathy, are the leading cause of blindness in working aged people. Sufferers can avoid blindness if identified early via retinal imaging. Systematic screening of the diabetic population has been shown to greatly reduce the prevalence and incidence of blindness within the population. Many national screening programs have digital fundus photography as their basis. In the past 5 years several techniques and adapters have been developed that allow digital fundus photography to be performed using smartphones. We review recent progress in smartphone-based fundus imaging and discuss its potential for integration into national systematic diabetic retinopathy screening programs. Some systems have produced promising initial results with respect to their agreement with reference standards. However further multisite trialling of such systems’ use within implementable screening workflows is required if an evidence base strong enough to affect policy change is to be established. If this were to occur national diabetic retinopathy screening would, for the first time, become possible in low- and middle-income settings where cost and availability of trained eye care personnel are currently key barriers to implementation. As diabetes prevalence and incidence is increasing sharply in these settings, the impact on global blindness could be profound. PMID:26596630

  15. The Diabetic Retinopathy Screening Workflow: Potential for Smartphone Imaging.

    Science.gov (United States)

    Bolster, Nigel M; Giardini, Mario E; Bastawrous, Andrew

    2015-11-23

    Complications of diabetes mellitus, namely diabetic retinopathy and diabetic maculopathy, are the leading cause of blindness in working aged people. Sufferers can avoid blindness if identified early via retinal imaging. Systematic screening of the diabetic population has been shown to greatly reduce the prevalence and incidence of blindness within the population. Many national screening programs have digital fundus photography as their basis. In the past 5 years several techniques and adapters have been developed that allow digital fundus photography to be performed using smartphones. We review recent progress in smartphone-based fundus imaging and discuss its potential for integration into national systematic diabetic retinopathy screening programs. Some systems have produced promising initial results with respect to their agreement with reference standards. However further multisite trialling of such systems' use within implementable screening workflows is required if an evidence base strong enough to affect policy change is to be established. If this were to occur national diabetic retinopathy screening would, for the first time, become possible in low- and middle-income settings where cost and availability of trained eye care personnel are currently key barriers to implementation. As diabetes prevalence and incidence is increasing sharply in these settings, the impact on global blindness could be profound. © 2015 Diabetes Technology Society.

  16. The Relationship Between Digit Independence and Digital Sesamoids in Humans and a Proposal of a New Digital Sesamoid Evolutionary Hypothesis.

    Science.gov (United States)

    Yammine, Kaissar

    2018-01-03

    Digital sesamoids are found in the metapodial-phalangeal joints of most mammals and quadrupedal tetrapods, yet their functional significance is still unclear. During primate evolution, a slight decline in their frequency has been associated with brachiation in gibbons, followed by a quasi-complete absence in orangutans then a slight resurgence occurred in gorillas and chimpanzees. Simultaneously, forearm muscles showed a progressive division in hominoid evolution towards a more "individualistic" musculature yielding more mobility and independence to some fingers. In humans, sesamoids are consistently observed in thumbs and big toes and frequently in other hypermobile digits such as the index and little fingers. Using a simple mathematical equation, this paper attempted to quantify a presumed association between hypermobile fingers and sesamoid frequency and distribution in humans. To this, an anatomic definition of digital independence has been formulated which includes three variables; (1) number and (2) frequency of independent flexor/extensor forearm muscles destined to a single finger, (3) and number of free/absent webspace. Results of previous meta-analyses and means of big sample studies were used to evaluate the frequency of such muscles. The expected values obtained via this model were found to be very close to the observed (published) values of the ossified sesamoids in human hands, and that in terms of frequency and distribution. The findings in humans showed a quasi-linear association between the degree of mobility and sesamoid frequency. The more the number of independent muscles destined to a finger, the more its metacarpo-phalangeal joint is likely to bear sesamoids. Based on our results and on a new analysis of primates' forearm/hand muscles and sesamoid evolution, a new hypothesis is proposed to answer two questions; the evolution of digital sesamoid frequency in primates and its sesamoid distribution in human digits. It claims that the number

  17. Magnitude and determinants of diabetic retinopathy among persons with diabetes registered at employee health department of a tertiary Eye Hospital of central Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Rajiv Khandekar

    2015-01-01

    Conclusions: Low coverage for eye screening and laser treatment to diabetics among the staff of an eye hospital is a matter of concern. The underlying causes of low coverage of screening, digital fundus photography as a screening tool and management should be addressed.

  18. Interaction domains in die-upset NdFeB magnets in dependence on the degree of deformation

    International Nuclear Information System (INIS)

    Khlopkov, K.; Gutfleisch, O.; Schaefer, R.; Hinz, D.; Mueller, K.-H.; Schultz, L.

    2004-01-01

    The magnetic domain structure of NdFeB magnets has been studied using high resolution, digitally enhanced Kerr-microscopy. Melt-spun NdFeB powder (MQU-F TM ) was hot pressed into fully dense samples and then hot deformed to axially textured magnets. Various degrees of deformation (height reduction) up to 76% have been realized. Pronounced interaction domains have been observed only in magnets, which were deformed to a degree of deformation of at least 52%. With increasing alignment of the grains the interaction domains become more and more visible and their size increases

  19. Issues for bringing digital libraries into public use

    Science.gov (United States)

    Flater, David W.; Yesha, Yelena

    1993-01-01

    In much the same way that the field of artificial intelligence produced a cult which fervently believed that computers would soon think like human beings, the existence of electronic books has resurrected the paperless society as a utopian vision to some, an apocalyptic horror to others. In this essay we have attempted to provide realistic notions of what digital libraries are likely to become if they are a popular success. E-books are capable of subsuming most of the media we use today and have the potential for added functionality by being interactive. The environmental impact of having millions more computers will be offset to some degree, perhaps even exceeded, by the fact that televisions, stereos, VCR's, CD players, newspapers, magazines, and books will become part of the computer system or be made redundant. On the whole, large-scale use of digital libraries is likely to be a winning proposition. Whether or not this comes to pass depends on the directions taken by today's researchers and software developers. By involving the public, the effort being put into digital libraries can be leveraged into something which is big enough to make a real change for the better. If digital libraries remain the exclusive property of government, universities, and large research firms, then large parts of the world will remain without digital libraries for years to come, just as they have remained without digital phone service for far too long. If software companies try to scuttle the project by patenting crucial algorithms and using proprietary data formats, all of us will suffer. Let us reverse the errors of the past and create a truly open digital library system.

  20. Accessible Geoscience - Digital Fieldwork

    Science.gov (United States)

    Meara, Rhian

    2017-04-01

    Accessible Geoscience is a developing field of pedagogic research aimed at widening participation in Geography, Earth and Environmental Science (GEES) subjects. These subjects are often less commonly associated with disabilities, ethnic minorities, low income socio-economic groups and females. While advancements and improvements have been made in the inclusivity of these subject areas in recent years, access and participation of disabled students remains low. While universities are legally obligated to provide reasonable adjustments to ensure accessibility, the assumed incompatibility of GEES subjects and disability often deters students from applying to study these courses at a university level. Instead of making reasonable adjustments if and when they are needed, universities should be aiming to develop teaching materials, spaces and opportunities which are accessible to all, which in turn will allow all groups to participate in the GEES subjects. With this in mind, the Swansea Geography Department wish to enhance the accessibility of our undergraduate degree by developing digital field work opportunities. In the first instance, we intend to digitise three afternoon excursions which are run as part of a 1st year undergraduate module. Each of the field trips will be digitized into English- and Welsh-medium formats. In addition, each field trip will be digitized into British Sign Language (BSL) to allow for accessibility for D/deaf and hard of hearing students. Subtitles will also be made available in each version. While the main focus of this work is to provide accessible fieldwork opportunities for students with disabilities, this work also has additional benefits. Students within the Geography Department will be able to revisit the field trips, to revise and complete associated coursework. The use of digitized field work should not replace opportunities for real field work, but its use by the full cohort of students will begin to "normalize" accessible field

  1. Agreement between image grading of conventional (45°) and ultra wide-angle (200°) digital images in the macula in the Reykjavik eye study.

    Science.gov (United States)

    Csutak, A; Lengyel, I; Jonasson, F; Leung, I; Geirsdottir, A; Xing, W; Peto, T

    2010-10-01

    To establish the agreement between image grading of conventional (45°) and ultra wide-angle (200°) digital images in the macula. In 2008, the 12-year follow-up was conducted on 573 participants of the Reykjavik Eye Study. This study included the use of the Optos P200C AF ultra wide-angle laser scanning ophthalmoscope alongside Zeiss FF 450 conventional digital fundus camera on 121 eyes with or without age-related macular degeneration using the International Classification System. Of these eyes, detailed grading was carried out on five cases each with hard drusen, geographic atrophy and chorioretinal neovascularisation, and six cases of soft drusen. Exact agreement and κ-statistics were calculated. Comparison of the conventional and ultra wide-angle images in the macula showed an overall 96.43% agreement (κ=0.93) with no disagreement at end-stage disease; although in one eye chorioretinal neovascularisation was graded as drusenoid pigment epithelial detachment. Of patients with drusen only, the exact agreement was 96.1%. The detailed grading showed no clinically significant disagreement between the conventional 45° and 200° images. On the basis of our results, there is a good agreement between grading conventional and ultra wide-angle images in the macula.

  2. Degree-degree correlations in directed networks with heavy-tailed degrees

    NARCIS (Netherlands)

    van der Hoorn, W.L.F.; Litvak, Nelli

    2013-01-01

    In network theory, Pearson's correlation coefficients are most commonly used to measure the degree assortativity of a network. We investigate the behavior of these coefficients in the setting of directed networks with heavy-tailed degree sequences. We prove that for graphs where the in- and

  3. Digital Natives or Digital Tribes?

    Science.gov (United States)

    Watson, Ian Robert

    2013-01-01

    This research builds upon the discourse surrounding digital natives. A literature review into the digital native phenomena was undertaken and found that researchers are beginning to identify the digital native as not one cohesive group but of individuals influenced by other factors. Primary research by means of questionnaire survey of technologies…

  4. Photon level chemical classification using digital compressive detection

    International Nuclear Information System (INIS)

    Wilcox, David S.; Buzzard, Gregery T.; Lucier, Bradley J.; Wang Ping; Ben-Amotz, Dor

    2012-01-01

    Highlights: ► A new digital compressive detection strategy is developed. ► Chemical classification demonstrated using as few as ∼10 photons. ► Binary filters are optimal when taking few measurements. - Abstract: A key bottleneck to high-speed chemical analysis, including hyperspectral imaging and monitoring of dynamic chemical processes, is the time required to collect and analyze hyperspectral data. Here we describe, both theoretically and experimentally, a means of greatly speeding up the collection of such data using a new digital compressive detection strategy. Our results demonstrate that detecting as few as ∼10 Raman scattered photons (in as little time as ∼30 μs) can be sufficient to positively distinguish chemical species. This is achieved by measuring the Raman scattered light intensity transmitted through programmable binary optical filters designed to minimize the error in the chemical classification (or concentration) variables of interest. The theoretical results are implemented and validated using a digital compressive detection instrument that incorporates a 785 nm diode excitation laser, digital micromirror spatial light modulator, and photon counting photodiode detector. Samples consisting of pairs of liquids with different degrees of spectral overlap (including benzene/acetone and n-heptane/n-octane) are used to illustrate how the accuracy of the present digital compressive detection method depends on the correlation coefficients of the corresponding spectra. Comparisons of measured and predicted chemical classification score plots, as well as linear and non-linear discriminant analyses, demonstrate that this digital compressive detection strategy is Poisson photon noise limited and outperforms total least squares-based compressive detection with analog filters.

  5. Degree-degree dependencies in directed networks with heavy-tailed degrees

    NARCIS (Netherlands)

    van der Hoorn, W.L.F.; Litvak, Nelly

    2015-01-01

    In network theory, Pearson’s correlation coefficients are most commonly used to measure the degree assortativity of a network. We investigate the behavior of these coefficients in the setting of directed networks with heavy-tailed degree sequences. We prove that for graphs where the in- and

  6. Development of digital photogrammetry for measurements of displacements in underground excavation

    International Nuclear Information System (INIS)

    Ohnishi, Yuzo; Ohtsu, Hiroyasu; Nishiyama, Satoshi; Ono, Tetsu; Matsui, Hiroya

    2002-03-01

    Because deformations are important indicators of the degree of stability during construction of rock structures, monitoring of deformation is a key element of construction of tunnels and structures for the underground research laboratory. Especially in the construction and maintenance of underground excavation, monitoring of deformations is needed for obtaining useful information to control its stability. We have been developing the application of digital photogrammetry to monitoring techniques in rock structures. Photogrammetric process has undergone a remarkable evolution with its transformation into digital photogrammetry. Photogrammetry has the advantage of measuring deformation of an object by some photos with easy measurements and excellent cost performance. In this paper, we present that the digital photogrammetry can monitor the displacements of the underground excavation accurately along with a capability of real-time measurement. (author)

  7. Avaliação ocular multimodal em doenças heredodistróficas e degenerativas da retina Multimodal fundus imaging in heredodystrophic and degenerative diseases of the retina

    Directory of Open Access Journals (Sweden)

    Daniela Cavalcanti Ferrara

    2009-10-01

    Full Text Available A tomografia de coerência óptica incorporou-se gradativamente ao contemporâneo arsenal diagnóstico em Oftalmologia, passando a exercer papel fundamental na investigação e condução de doenças oculares, particularmente na especialidade de Retina e Vítreo. A disponibilização comercial da nova geração de aparelhos, chamada de tomografia de coerência óptica "espectral", baseada em conceito físico distinto que permite a aquisição de imagens em alta velocidade, marcou o início de uma nova era desta tecnologia de investigação auxiliar. Adicionalmente, sua recente combinação com o oftalmoscópio de varredura a laser confocal (confocal scanning laser ophthalmoscope vem propiciando a aquisição de imagens tomográficas guiadas em tempo real pelos diferentes modos de imagem (autofluorescência de fundo, reflectância com luz "infravermelha" e angiografia com fluoresceína ou indocianina verde. A avaliação ocular multimodal (multimodal fundus imaging permite a correlação real e minuciosa de achados da morfologia retiniana e do epitélio pigmentar com dados de estudos angiográficos e de autofluorescência ou reflectância, propiciando assim inferências valiosas sobre a fisiologia do tecido. Neste artigo, discutimos brevemente as possíveis implicações da avaliação ocular multimodal na prática da especialidade de Retina e Vítreo.Optical coherence tomography was progressively incorporated to the contemporary diagnostic arsenal in Ophthalmology, playing a crucial role in the diagnosis and management of eye diseases, particularly in the specialty of retina and vitreous. The commercial availability of the new generation of devices, coined "spectral" optical coherence tomography, which is based in a distinct physical concept that permits high-speed image acquisition, launched a new era for this investigative ancillary tool. In addition, the recent combination of this new technology with a confocal scanning laser ophthalmoscope

  8. Digital platforms as enablers for digital transformation

    DEFF Research Database (Denmark)

    Hossain, Mokter; Lassen, Astrid Heidemann

    transformation is crucial. This study aims at exploring how organizations are driven towards transformation in various ways to embrace digital platforms for ideas, technologies, and knowledge. It shows the opportunities and challenges digital platforms bring in organizations. It also highlights underlying......Digital platforms offer new ways for organizations to collaborate with the external environment for ideas, technologies, and knowledge. They provide new possibilities and competence but they also bring new challenges for organizations. Understanding the role of these platforms in digital...... mechanisms and potential outcomes of various digital platforms. The contribution of the submission is valuable for scholars to understand and further explore this area. It provides insight for practitioners to capture value through digital platforms and accelerate the pace of organizations’ digital...

  9. Digital terrain data base - new possibilities of 3D terrain modeling

    Directory of Open Access Journals (Sweden)

    Mateja Rihtaršič

    1992-12-01

    Full Text Available GISs has brought new dimensions in the field of digital terrain modelling, too. Modem DTMs must be real (relational databases with high degree of "intelligence". This paper presents some of the demands, ivhich have to be solved in modern digital terrain databases, together with main steps of their's generation. Problems, connected to regional level, multi-pur pose use, new possibilities and direct integration into GIS are presented. The practical model was created across smaller test area, so few lines with practical experiences can be droped, too.

  10. Automated retinal nerve fiber layer defect detection using fundus imaging in glaucoma.

    Science.gov (United States)

    Panda, Rashmi; Puhan, N B; Rao, Aparna; Padhy, Debananda; Panda, Ganapati

    2018-06-01

    Retinal nerve fiber layer defect (RNFLD) provides an early objective evidence of structural changes in glaucoma. RNFLD detection is currently carried out using imaging modalities like OCT and GDx which are expensive for routine practice. In this regard, we propose a novel automatic method for RNFLD detection and angular width quantification using cost effective redfree fundus images to be practically useful for computer-assisted glaucoma risk assessment. After blood vessel inpainting and CLAHE based contrast enhancement, the initial boundary pixels are identified by local minima analysis of the 1-D intensity profiles on concentric circles. The true boundary pixels are classified using random forest trained by newly proposed cumulative zero count local binary pattern (CZC-LBP) and directional differential energy (DDE) along with Shannon, Tsallis entropy and intensity features. Finally, the RNFLD angular width is obtained by random sample consensus (RANSAC) line fitting on the detected set of boundary pixels. The proposed method is found to achieve high RNFLD detection performance on a newly created dataset with sensitivity (SN) of 0.7821 at 0.2727 false positives per image (FPI) and the area under curve (AUC) value is obtained as 0.8733. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Digital citizens Digital nations: the next agenda

    NARCIS (Netherlands)

    A.W. (Bert) Mulder; M.W. (Martijn) Hartog

    2015-01-01

    DIGITAL CITIZENS CREATE A DIGITAL NATION Citizens will play the lead role as they – in the next phase of the information society – collectively create a digital nation. Personal adoption of information and communication technology will create a digital infrastructure that supports individual and

  12. Going digital: a checklist in preparing for hospital-wide electronic medical record implementation and digital transformation.

    Science.gov (United States)

    Scott, Ian A; Sullivan, Clair; Staib, Andrew

    2018-05-24

    to implement, hospital wide electronic medical records (EMRs) with varying degrees of functionality. Few hospitals have implemented a complete end-to-end digital system with the ability to bring about major transformation in clinical care. Although the many challenges in implementing EMRs have been well documented, they have not been incorporated into an evidence-based, field-tested checklist that can practically assist hospitals in preparing for EMR implementation as both a technical innovation and a vehicle for major digital transformation of care. What does this paper add? This paper outlines a 19-question checklist that was developed using a formal methodological framework comprising literature review of relevant issues, proceedings from an interactive workshop involving a multidisciplinary group of digital leads from hospitals throughout Queensland, including three hospitals undertaking EMR implementation and one hospital with complete end-to-end EMR, and review of a draft checklist by senior clinical leads within a statewide digital healthcare improvement network. The checklist distinguishes between issues pertaining to EMR as a technical innovation and EMR as a vehicle for digital transformation of patient care. What are the implications for practitioners? Successful implementation of a hospital-wide EMR requires senior managers, clinical leads, information technology teams and project management teams to fully address key operational and strategic issues. Using an issues checklist may help prevent any one issue being inadvertently overlooked or underemphasised in the planning and implementation stages, and ensure the EMR is fully adopted and optimally used by clinician users in an ongoing digital transformation of care.

  13. Automatic detection of the macula in retinal fundus images using seeded mode tracking approach.

    Science.gov (United States)

    Wong, Damon W K; Liu, Jiang; Tan, Ngan-Meng; Yin, Fengshou; Cheng, Xiangang; Cheng, Ching-Yu; Cheung, Gemmy C M; Wong, Tien Yin

    2012-01-01

    The macula is the part of the eye responsible for central high acuity vision. Detection of the macula is an important task in retinal image processing as a landmark for subsequent disease assessment, such as for age-related macula degeneration. In this paper, we have presented an approach to automatically determine the macula centre in retinal fundus images. First contextual information on the image is combined with a statistical model to obtain an approximate macula region of interest localization. Subsequently, we propose the use of a seeded mode tracking technique to locate the macula centre. The proposed approach is tested on a large dataset composed of 482 normal images and 162 glaucoma images from the ORIGA database and an additional 96 AMD images. The results show a ROI detection of 97.5%, and 90.5% correct detection of the macula within 1/3DD from a manual reference, which outperforms other current methods. The results are promising for the use of the proposed approach to locate the macula for the detection of macula diseases from retinal images.

  14. Vogt-小柳-原田综合征的眼底荧光血管造影分析%Study and analysis of Vogt-Koyanagi-Harada syndrome by fundus fluorescein angiography

    Institute of Scientific and Technical Information of China (English)

    曹芳

    2014-01-01

    目的:探讨 Vogt-小柳-原田综合征( Vogt-Koyanagi-Harada syndrome, VKHS )的眼底荧光血管造影( fundus fluorescein angiography,FFA)的表现及其临床意义。  方法:对VKHS患者16例30眼进行眼部详细检查,并行眼底彩色照相和FFA等检查。  结果:Vogt-小柳-原田综合征葡萄膜炎期的眼底表现为3种类型,脉络膜炎性渗出及渗出性视网膜脱离是视力损害的主要原因,而视盘水肿充血对视力损害较轻,且恢复较好。  结论:FFA的特征性表现对该病早期具有重要诊断意义。%AIM:To study cilncial features and significance of Vogt-Koyanagi - Harada syndrome ( VKHS ) by fundus fluorescein angiography ( FFA) . METHODS: All 16 cases ( 30 eyes ) of VKHS were underwent by detailed paysical examination. Then took colour photographs and examined by FFA. RESULTS:Uveitis stage of VKHS could be classified into three kinds of fundus appearances. The vision damage was mainly associated to exudation of choroidal vessel and exsudative retinal detachment rather than edema of optic disc which could achieve a better recovery. CONCLUSION: FFA is an important and valuable examination to diagnose the VKHS forepart.

  15. Factors enhancing learning possibilities in digital workshops

    Directory of Open Access Journals (Sweden)

    Christian Kobbernagel

    2014-05-01

    Full Text Available This article presents a study of processes supporting student learning possibilities in digital workshops planned and held at art museums in Denmark. The investigation aims to provide insights into factors enhancing learning possibilities, including the educator’s dialogic performance, experiences of art, and perceived qualities of digital content creation processes in art museum education workshops. To address the research question of what conditional and processual factors can be said to support learning possibilities, a model was developed on the basis of fieldwork and theories of media education, art pedagogy and motivation. The model was then analyzed using structural equation modelling (SEM on data collected (N= 502 after workshops in two museums. The results suggest that the dialogic performance of museum educators, a positive art experience and positive perceptions of working with digital media are factors that strongly support student participation and reflection – although to various degrees. The findings also show that, in cases in which students are disinterested and see little value in participating during the workshop, this amotivation is likely to be lower when their art experiences and their perceptions of the media production process are positive. 

  16. Factors enhancing learning possibilities in digital workshops

    Directory of Open Access Journals (Sweden)

    Christian Kobbernagel

    2014-06-01

    Full Text Available This article presents a study of processes supporting student learning possibilities in digital workshops planned and held at art museums in Denmark. The investigation aims to provide insights into factors enhancing learning possibilities, including the educator’s dialogic performance, experiences of art, and perceived qualities of digital content creation processes in art museum education workshops. To address the research question of what conditional and processual factors can be said to support learning possibilities, a model was developed on the basis of fieldwork and theories of media education, art pedagogy and motivation. The model was then analyzed using structural equation modelling (SEM on data collected (N= 502 after workshops in two museums. The results suggest that the dialogic performance of museum educators, a positive art experience and positive perceptions of working with digital media are factors that strongly support student participation and reflection – although to various degrees. The findings also show that, in cases in which students are disinterested and see little value in participating during the workshop, this amotivation is likely to be lower when their art experiences and their perceptions of the media production process are positive.

  17. Digital case-based learning system in school.

    Science.gov (United States)

    Gu, Peipei; Guo, Jiayang

    2017-01-01

    With the continuing growth of multi-media learning resources, it is important to offer methods helping learners to explore and acquire relevant learning information effectively. As services that organize multi-media learning materials together to support programming learning, the digital case-based learning system is needed. In order to create a case-oriented e-learning system, this paper concentrates on the digital case study of multi-media resources and learning processes with an integrated framework. An integration of multi-media resources, testing and learning strategies recommendation as the learning unit is proposed in the digital case-based learning framework. The learning mechanism of learning guidance, multi-media materials learning and testing feedback is supported in our project. An improved personalized genetic algorithm which incorporates preference information and usage degree into the crossover and mutation process is proposed to assemble the personalized test sheet for each learner. A learning strategies recommendation solution is proposed to recommend learning strategies for learners to help them to learn. The experiments are conducted to prove that the proposed approaches are capable of constructing personalized sheets and the effectiveness of the framework.

  18. Digital case-based learning system in school.

    Directory of Open Access Journals (Sweden)

    Peipei Gu

    Full Text Available With the continuing growth of multi-media learning resources, it is important to offer methods helping learners to explore and acquire relevant learning information effectively. As services that organize multi-media learning materials together to support programming learning, the digital case-based learning system is needed. In order to create a case-oriented e-learning system, this paper concentrates on the digital case study of multi-media resources and learning processes with an integrated framework. An integration of multi-media resources, testing and learning strategies recommendation as the learning unit is proposed in the digital case-based learning framework. The learning mechanism of learning guidance, multi-media materials learning and testing feedback is supported in our project. An improved personalized genetic algorithm which incorporates preference information and usage degree into the crossover and mutation process is proposed to assemble the personalized test sheet for each learner. A learning strategies recommendation solution is proposed to recommend learning strategies for learners to help them to learn. The experiments are conducted to prove that the proposed approaches are capable of constructing personalized sheets and the effectiveness of the framework.

  19. The Curriculum Planning Process for Undergraduate Game Degree Programs in the United Kingdom and United States

    Science.gov (United States)

    McGill, Monica M.

    2012-01-01

    Digital games are marketed, mass-produced, and consumed by an increasing number of people and the game industry is only expected to grow. In response, postsecondary institutions in the UK and the U.S. have started to create game degree programs. Though curriculum theorists provide insight into the process of creating a new program, no formal…

  20. Ultra-widefield fundus autofluorescence in age-related macular degeneration.

    Directory of Open Access Journals (Sweden)

    Abhilash Guduru

    Full Text Available Establish accuracy and reproducibility of subjective grading in ultra-widefield fundus autofluorescence (FAF imaging in patients with age-related macular degeneration (AMD, and determine if an association exists between peripheral FAF abnormalities and AMD.This was a prospective, single-blinded case-control study. Patients were consecutively recruited for the study. Patients were excluded if there was a history of prior or active ocular pathology other than AMD or image quality was insufficient for analysis as determined by two independent graders. Control patients were those without any evidence of AMD or other ophthalmic disease apart from cataract. Using the Optos 200Tx (Optos, Marlborough, MA, USA, a ResMax central macula and an ultra-widefield peripheral retina image was taken for each eye in both normal color and short wavelength FAF. Ultra-widefield photographs were modified to mask the macula. Each ResMax and ultra-widefield image was independently graded by two blinded investigators.There were 28 AMD patients and 11 controls. There was a significant difference in the average age between AMD patients and control groups (80 versus 64, respectively P<0.001. There was moderate, statistically significant agreement between observers regarding image interpretation (78.4%, K = 0.524, P<0.001, and 69.0% (K = 0.49, P<0.001 agreement between graders for FAF abnormality patterns. Patients with AMD were at greater risk for peripheral FAF abnormalities (OR: 3.43, P = 0.019 and patients with FAF abnormalities on central macular ResMax images were at greater risk of peripheral FAF findings (OR: 5.19, P = 0.017.Subjective interpretation of FAF images has moderate reproducibility and validity in assessment of peripheral FAF abnormalities. Peripheral FAF abnormalities are seen in both AMD and control patients. Those with AMD, poor visual acuity, and macular FAF abnormalities are at greater risk.

  1. Digital Records Forensics: A New Science and Academic Program for Forensic Readiness

    Directory of Open Access Journals (Sweden)

    Luciana Duranti

    2010-06-01

    Full Text Available This paper introduces the Digital Records Forensics project, a research endeavour located at the University of British Columbia in Canada and aimed at the development of a new science resulting from the integration of digital forensics with diplomatics, archival science, information science and the law of evidence, and of an interdisciplinary graduate degree program, called Digital Records Forensics Studies, directed to professionals working for law enforcement agencies, legal firms, courts, and all kind of institutions and business that require their services. The program anticipates the need for organizations to become “forensically ready,” defined by John Tan as “maximizing the ability of an environment to collect credible digital evidence while minimizing the cost of an incident response (Tan, 2001.” The paper argues the need for such a program, describes its nature and content, and proposes ways of delivering it.

  2. Diagnostic image quality of video-digitized chest images

    International Nuclear Information System (INIS)

    Winter, L.H.; Butler, R.B.; Becking, W.B.; Warnars, G.A.O.; Haar Romeny, B. ter; Ottes, F.P.; Valk, J.-P.J. de

    1989-01-01

    The diagnostic accuracy obtained with the Philips picture archiving and communications subsystem was investigated by means of an observer performance study using receiver operating characteristic (ROC) analysis. The image qualities of conventional films and video digitized images were compared. The scanner had a 1024 x 1024 x 8 bit memory. The digitized images were displayed on a 60 Hz interlaced display monitor 1024 lines. Posteroanterior (AP) roetgenograms of a chest phantom with superimposed simulated interstitial pattern disease (IPD) were produced; there were 28 normal and 40 abnormal films. Normal films were produced by the chest phantom alone. Abnormal films were taken of the chest phantom with varying degrees of superimposed simulated intersitial disease (PND) for an observer performance study, because the results of a simulated interstitial pattern disease study are less likely to be influenced by perceptual capabilities. The conventional films and the video digitized images were viewed by five experienced observers during four separate sessions. Conventional films were presented on a viewing box, the digital images were displayed on the monitor described above. The presence of simulated intersitial disease was indicated on a 5-point ROC certainty scale by each observer. We analyzed the differences between ROC curves derived from correlated data statistically. The mean time required to evaluate 68 digitized images is approximately four times the mean time needed to read the convential films. The diagnostic quality of the video digitized images was significantly lower (at the 5% level) than that of the conventional films (median area under the curve (AUC) of 0.71 and 0.94, respectively). (author). 25 refs.; 2 figs.; 4 tabs

  3. Digital Materials - Evaluation of the Possibilities of using Selected Hyperelastic Models to Describe Constitutive Relations

    Science.gov (United States)

    Mańkowski, J.; Lipnicki, J.

    2017-08-01

    The authors tried to identify the parameters of numerical models of digital materials, which are a kind of composite resulting from the manufacture of the product in 3D printers. With the arrangement of several heads of the printer, the new material can result from mixing of materials with radically different properties, during the process of producing single layer of the product. The new material has properties dependent on the base materials properties and their proportions. Digital materials tensile characteristics are often non-linear and qualify to be described by hyperelastic materials models. The identification was conducted based on the results of tensile tests models, its various degrees coefficients of the polynomials to various degrees coefficients of the polynomials. The Drucker's stability criterion was also examined. Fourteen different materials were analyzed.

  4. Digital forensics digital evidence in criminal investigations

    CERN Document Server

    Marshall, Angus McKenzie

    2009-01-01

    The vast majority of modern criminal investigations involve some element of digital evidence, from mobile phones, computers, CCTV and other devices. Digital Forensics: Digital Evidence in Criminal Investigations provides the reader with a better understanding of how digital evidence complements "traditional" scientific evidence and examines how it can be used more effectively and efficiently in a range of investigations. Taking a new approach to the topic, this book presents digital evidence as an adjunct to other types of evidence and discusses how it can be deployed effectively in s

  5. Minimization In Digital Design As A Meta-Planning Problem

    Science.gov (United States)

    Ho, William P. C.; Wu, Jung-Gen

    1987-05-01

    In our model-based expert system for automatic digital system design, we formalize the design process into three sub-processes - compiling high-level behavioral specifications into primitive behavioral operations, grouping primitive operations into behavioral functions, and grouping functions into modules. Consideration of design minimization explicitly controls decision-making in the last two subprocesses. Design minimization, a key task in the automatic design of digital systems, is complicated by the high degree of interaction among the time sequence and content of design decisions. In this paper, we present an AI approach which directly addresses these interactions and their consequences by modeling the minimization prob-lem as a planning problem, and the management of design decision-making as a meta-planning problem.

  6. Pitfalls in colour photography of choroidal tumours

    Science.gov (United States)

    Schalenbourg, A; Zografos, L

    2013-01-01

    Colour imaging of fundus tumours has been transformed by the development of digital and confocal scanning laser photography. These advances provide numerous benefits, such as panoramic images, increased contrast, non-contact wide-angle imaging, non-mydriatic photography, and simultaneous angiography. False tumour colour representation can, however, cause serious diagnostic errors. Large choroidal tumours can be totally invisible on angiography. Pseudogrowth can occur because of artefacts caused by different methods of fundus illumination, movement of reference blood vessels, and flattening of Bruch's membrane and sclera when tumour regression occurs. Awareness of these pitfalls should prevent the clinician from misdiagnosing tumours and wrongfully concluding that a tumour has grown. PMID:23238442

  7. Pitfalls in colour photography of choroidal tumours.

    Science.gov (United States)

    Schalenbourg, A; Zografos, L

    2013-02-01

    Colour imaging of fundus tumours has been transformed by the development of digital and confocal scanning laser photography. These advances provide numerous benefits, such as panoramic images, increased contrast, non-contact wide-angle imaging, non-mydriatic photography, and simultaneous angiography. False tumour colour representation can, however, cause serious diagnostic errors. Large choroidal tumours can be totally invisible on angiography. Pseudogrowth can occur because of artefacts caused by different methods of fundus illumination, movement of reference blood vessels, and flattening of Bruch's membrane and sclera when tumour regression occurs. Awareness of these pitfalls should prevent the clinician from misdiagnosing tumours and wrongfully concluding that a tumour has grown.

  8. Digital radiology and digitally formatted image management systems

    International Nuclear Information System (INIS)

    Cox, G.G.; Dwyer, S.J. III; Templeton, A.W.

    1987-01-01

    The number of diagnostic examinations performed with digitally formatted imaging equipment is increasing. Digital general-purpose and fluoroscopic radiology systems are being clinically evaluated. Digitizing conventional x-ray films, such as mammograms, frequently improves the diagnostic quality of the images. The digitizing process with laser has also afforded the opportunity to document required spatial resolution for digital imaging and network systems. The use of digitally formatted image instrumentation imposes new requirements on the acquisition, display and manipulation, transmission, hard copy image recording, and archiving of diagnostic data. Networking of digitally formatted image data offers many advantages for managing digital information. This paper identifies and describes digital radiographic systems. Parameters required for designing and implementing a digital image management system are outlined. Spatial and contrast resolution requirements are identified. The key parameters include the amount of image data generated each working day, the retrieval rate of the generated data, the display hardware and software needed for interactive diagnosis display stations, the requirements for analog hard copy generation, and on-line and long-term archiving requirements. These image management systems are often called PACS (Picture Archiving and Communication Systems)

  9. 5 Meter Alaska Digital Elevation Models (DEMs) - USGS National Map 3DEP Downloadable Data Collection

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This dataset is comprised of 5-meter ifsar-derived Digital Elevation Models (DEMs) over Alaska only. It is distributed as one-degree blocks with overedge. Horizontal...

  10. A digital signal processor based rf control system for the TRIUMF ISAC RFQ prototype

    International Nuclear Information System (INIS)

    Fong, K.; Fang, S.; Laverty, M.

    1996-01-01

    A stand alone digital signal processor is used to control the RFQ prototype in the TRIUMF ISAC development program. The advantage of a digital control system over the traditional analogue system is that it offers the higher degree of flexibility necessary for a development system. For this application the system is designed to have the outward appearance of an analogue system, and uses dials, knobs, and switches as the operator interface. The digital signal processor is used as a feedback controller during CW rf operation, with the feedback gain parameters continually adjustable. It is also able to perform the same regulation during pulsed operation, with additional feedforward compensation for initial pulse on duration. Using a low cost analogue-to-digital converter with a sample rate of 100 kHz, a regulation bandwidth of 10 kHz is achieved. (author)

  11. Digital citizenship and neoliberalization: governing digital citizens in Denmark

    DEFF Research Database (Denmark)

    Schou, Jannick; Hjelholt, Morten

    2018-01-01

    Digital citizenship is becoming increasingly normalized within advanced democratic states. As society and governmental institutions become reliant on digital technologies, citizens are expected to be and act digitally. This article examines the governance of digital citizens through a case study...... this case study, the article contributes to current critical perspectives on the digital citizen as a new political figure. It adds new insights into digital citizenship by connecting this figure to wider processes of neoliberalization and state restructuring, pushing for a more pronounced focus...... of digitalization efforts in Denmark. Drawing on multiple forms of data, the article showcases how digital citizens are governed through a combination of discursive, legal and institutional means. The article highlights the political, but also institutional work that goes into making citizens digital. Providing...

  12. A COMPREHENSIVE MODEL FOR THE POWER TRANSFORMER DIGITAL DIFFERENTIAL PROTECTION FUNCTIONING RESEARCH

    Directory of Open Access Journals (Sweden)

    Yu. V. Rumiantsev

    2016-01-01

    Full Text Available This article presents a comprehensive model for the two-winding power transformer digital differential protection functioning research. Considered comprehensive model is developed in MatLab-Simulink dynamic simulation environment with the help of SimPowerSystems component library and includes the following elements: power supply, three-phase power transformer, wye-connected current transformers and two-winding power transformer digital differential protection model. Each element of the presented model is described in the degree sufficient for its implementation in the dynamic simulation environment. Particular attention is paid to the digital signal processing principles and to the ways of differential and restraining currents forming of the considered comprehensive model main element – power transformer digital differential protection. With the help of this model the power transformer digital differential protection functioning was researched during internal and external faults: internal short-circuit, external short-circuit with and without current transformers saturation on the power transformer low-voltage side. Each experiment is illustrated with differential and restraining currents waveforms of the digital differential protection under research. Particular attention was paid to the digital protection functioning analysis during power transformer abnormal modes: overexcitation and inrush current condition. Typical current waveforms during these modes were showed and their harmonic content was investigated. The causes of these modes were analyzed in details. Digital differential protection blocking algorithms based on the harmonic content were considered. Drawbacks of theses algorithms were observed and the need of their further technical improvement was marked.

  13. Satisfaction and Dissatisfaction: Formulating Digital Marketing Strategy for Online Faith-Based Education

    Science.gov (United States)

    Price, Kelly; Price, Julia

    2016-01-01

    When digitally marketing an online educational program, degree or course, an institution must realize the target market which it is trying to reach. However, the demographics of the online student is extremely diverse, making marketing efforts difficult. With such a demographically diverse online student population to attract, it is important to…

  14. Digital radiography

    International Nuclear Information System (INIS)

    Brody, W.R.

    1984-01-01

    Digital Radiography begins with an orderly introduction to the fundamental concepts of digital imaging. The entire X-ray digital imagining system is described, from an overall characterization of image quality to specific components required for a digital radiographic system. Because subtraction is central to digital radiographic systems, the author details the use of various subtraction methods for image enhancement. Complex concepts are illustrated with numerous examples and presented in terms that can readily be understood by physicians without an advanced mathematics background. The second part of the book discusses implementations and applications of digital imagining systems based on area and scanned detector technologies. This section includes thorough coverage of digital fluoroscopy, scanned projection radiography, and film-based digital imaging systems, and features a state-of-the-art synopsis of the applications of digital subtraction angiography. The book concludes with a timely assessment of anticipated technological advances

  15. Licensing of digital Instrumentation and Control in Radioisotope Production Facility

    International Nuclear Information System (INIS)

    Abdel-Aziz, L.Kh.; Lashin, R.; Mostafa, W.

    2012-01-01

    In spite of the rapid development of digital I and C systems in all major industries, it has for several reasons been slower in nuclear power plants. The most important reason is that only a few new plants have been ordered worldwide during the last ten years. A second reason is connected to the efforts needed in providing adequate evidence that the digital I and C system can be used in safety and safety related applications. This issue is connected to the effort needed in obtaining adequate assurance that the digital I and C will fulfill its intended function and contain no unintended function in all possible operational states during its entire life cycle. This paper presents an acceptance criteria for licensing a digital instrumentation and control system in a Radioisotope Production Facility(1), which is under commissioning. The acceptance criteria ensure that the I and C systems are designed to reach the highest degree of reliability with respect to the function they perform, operators will have clear and accessible availability to data on every plant parameter, and also ensure that the safety objectives have been covered

  16. Endoscopically Assisted Drilling, Exposure of the Fundus through a Presigmoid Retrolabyrinthine Approach: A Cadaveric Feasibility Study.

    Science.gov (United States)

    Muelleman, Thomas; Shew, Matthew; Alvi, Sameer; Shah, Kushal; Staecker, Hinrich; Chamoun, Roukouz; Lin, James

    2018-01-01

    The presigmoid retrolabyrinthine approach to the cerebellopontine angle is traditionally described to not provide access to the internal auditory canal (IAC). We aimed to evaluate the extent of the IAC that could be exposed with endoscopically assisted drilling and to measure the percentage of the IAC that could be visualized with the microscope and various endoscopes after drilling had been completed. Presigmoid retrolabyrinthine approaches were performed bilaterally on 4 fresh cadaveric heads. We performed endoscopically assisted drilling to expose the fundus of the IAC, which resulted in exposure of the entire IAC in 8 of 8 temporal bone specimens. The microscope afforded a mean view of 83% (n = 8) of the IAC. The 0°, 30°, 45°, and 70° endoscope each afforded a view of 100% of the IAC in 8 of 8 temporal bone specimens. In conclusion, endoscopic drilling of the IAC of can provide an extradural means of exposing the entire length of the IAC while preserving the labyrinth.

  17. En Face Optical Coherence Tomography Angiography Imaging Versus Fundus Photography in the Measurement of Choroidal Nevi.

    Science.gov (United States)

    Lee, Michele D; Kaidonis, Georgia; Kim, Alice Y; Shields, Ryan A; Leng, Theodore

    2017-09-01

    Choroidal nevi are common benign intraocular tumors with a small risk of malignant transformation. This retrospective study investigates the use of en face spectral-domain optical coherence tomography angiography (SD-OCTA) in determining the clinical features and measurement of choroidal nevi. Patients with choroidal nevi were imaged with both OCTA and a fundus photography device. Greatest longitudinal dimension (GLD), perpendicular dimension (PD), and the GLD/PD ratio were assessed on each device. Inter-device variation and intra- and inter-rater reliability analyses were performed. Fourteen patients with choroidal nevi were included. No significant difference between the GLD/PD ratio as measured by all three devices was found (Chi-square = 2.8, 2 df, P = .247). Intraclass correlation coefficients were greater than 0.7 for repeated measures on all devices, suggesting good repeatability and reproducibility. This study demonstrated inter-device consistency and high intra- and inter-rater reliability when measuring choroidal nevi. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:741-747.]. Copyright 2017, SLACK Incorporated.

  18. Automated analysis of retinal imaging using machine learning techniques for computer vision [version 2; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Jeffrey De Fauw

    2017-06-01

    Full Text Available There are almost two million people in the United Kingdom living with sight loss, including around 360,000 people who are registered as blind or partially sighted. Sight threatening diseases, such as diabetic retinopathy and age related macular degeneration have contributed to the 40% increase in outpatient attendances in the last decade but are amenable to early detection and monitoring. With early and appropriate intervention, blindness may be prevented in many cases. Ophthalmic imaging provides a way to diagnose and objectively assess the progression of a number of pathologies including neovascular (“wet” age-related macular degeneration (wet AMD and diabetic retinopathy. Two methods of imaging are commonly used: digital photographs of the fundus (the ‘back’ of the eye and Optical Coherence Tomography (OCT, a modality that uses light waves in a similar way to how ultrasound uses sound waves. Changes in population demographics and expectations and the changing pattern of chronic diseases creates a rising demand for such imaging. Meanwhile, interrogation of such images is time consuming, costly, and prone to human error. The application of novel analysis methods may provide a solution to these challenges. This research will focus on applying novel machine learning algorithms to automatic analysis of both digital fundus photographs and OCT in Moorfields Eye Hospital NHS Foundation Trust patients. Through analysis of the images used in ophthalmology, along with relevant clinical and demographic information, DeepMind Health will investigate the feasibility of automated grading of digital fundus photographs and OCT and provide novel quantitative measures for specific disease features and for monitoring the therapeutic success.

  19. Automated analysis of retinal imaging using machine learning techniques for computer vision [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Jeffrey De Fauw

    2016-07-01

    Full Text Available There are almost two million people in the United Kingdom living with sight loss, including around 360,000 people who are registered as blind or partially sighted. Sight threatening diseases, such as diabetic retinopathy and age related macular degeneration have contributed to the 40% increase in outpatient attendances in the last decade but are amenable to early detection and monitoring. With early and appropriate intervention, blindness may be prevented in many cases.   Ophthalmic imaging provides a way to diagnose and objectively assess the progression of a number of pathologies including neovascular (“wet” age-related macular degeneration (wet AMD and diabetic retinopathy. Two methods of imaging are commonly used: digital photographs of the fundus (the ‘back’ of the eye and Optical Coherence Tomography (OCT, a modality that uses light waves in a similar way to how ultrasound uses sound waves. Changes in population demographics and expectations and the changing pattern of chronic diseases creates a rising demand for such imaging. Meanwhile, interrogation of such images is time consuming, costly, and prone to human error. The application of novel analysis methods may provide a solution to these challenges.   This research will focus on applying novel machine learning algorithms to automatic analysis of both digital fundus photographs and OCT in Moorfields Eye Hospital NHS Foundation Trust patients.   Through analysis of the images used in ophthalmology, along with relevant clinical and demographic information, Google DeepMind Health will investigate the feasibility of automated grading of digital fundus photographs and OCT and provide novel quantitative measures for specific disease features and for monitoring the therapeutic success.

  20. Magnetic field control of 90 Degree-Sign , 180 Degree-Sign , and 360 Degree-Sign domain wall resistance

    Energy Technology Data Exchange (ETDEWEB)

    Majidi, Roya, E-mail: royamajidi@gmail.com [Department of Physics, Shahid Rajaee Teacher Training University, Lavizan, 16788-15811 Tehran (Iran, Islamic Republic of)

    2012-10-01

    In the present work, we have compared the resistance of the 90 Degree-Sign , 180 Degree-Sign , and 360 Degree-Sign domain walls in the presence of external magnetic field. The calculations are based on the Boltzmann transport equation within the relaxation time approximation. One-dimensional Neel-type domain walls between two domains whose magnetization differs by angle of 90 Degree-Sign , 180 Degree-Sign , and 360 Degree-Sign are considered. The results indicate that the resistance of the 360 Degree-Sign DW is more considerable than that of the 90 Degree-Sign and 180 Degree-Sign DWs. It is also found that the domain wall resistance can be controlled by applying transverse magnetic field. Increasing the strength of the external magnetic field enhances the domain wall resistance. In providing spintronic devices based on magnetic nanomaterials, considering and controlling the effect of domain wall on resistivity are essential.

  1. Automated Detection of Microaneurysms Using Scale-Adapted Blob Analysis and Semi-Supervised Learning

    Energy Technology Data Exchange (ETDEWEB)

    Adal, Kedir M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sidebe, Desire [Univ. of Burgundy, Dijon (France); Ali, Sharib [Univ. of Burgundy, Dijon (France); Chaum, Edward [Univ. of Tennessee, Knoxville, TN (United States); Karnowski, Thomas Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Meriaudeau, Fabrice [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-01-07

    Despite several attempts, automated detection of microaneurysm (MA) from digital fundus images still remains to be an open issue. This is due to the subtle nature of MAs against the surrounding tissues. In this paper, the microaneurysm detection problem is modeled as finding interest regions or blobs from an image and an automatic local-scale selection technique is presented. Several scale-adapted region descriptors are then introduced to characterize these blob regions. A semi-supervised based learning approach, which requires few manually annotated learning examples, is also proposed to train a classifier to detect true MAs. The developed system is built using only few manually labeled and a large number of unlabeled retinal color fundus images. The performance of the overall system is evaluated on Retinopathy Online Challenge (ROC) competition database. A competition performance measure (CPM) of 0.364 shows the competitiveness of the proposed system against state-of-the art techniques as well as the applicability of the proposed features to analyze fundus images.

  2. Learning Analytics and Digital Badges: Potential Impact on Student Retention in Higher Education

    Science.gov (United States)

    Mah, Dana-Kristin

    2016-01-01

    Learning analytics and digital badges are emerging research fields in educational science. They both show promise for enhancing student retention in higher education, where withdrawals prior to degree completion remain at about 30% in Organisation for Economic Cooperation and Development member countries. This integrative review provides an…

  3. Digitization

    DEFF Research Database (Denmark)

    Finnemann, Niels Ole

    2014-01-01

    what a concept of digital media might add to the understanding of processes of mediatization and what the concept of mediatization might add to the understanding of digital media. It is argued that digital media open an array of new trajectories in human communication, trajectories which were...

  4. The New Digital Divide For Digital BioMarkers.

    Science.gov (United States)

    Torous, John; Rodriguez, Jorge; Powell, Adam

    2017-09-01

    As smartphone and sensors continue to become more ubiquitous across the world, digital biomarkers have emerged as a scalable and practical tool to explore disease states and advance health. But as the digital divide of access and ownership begins to fade, a new digital divide is emerging. Who are the types of people that own smartphones or smart watches, who are the types of people that download health apps or partake in digital biomarker studies, and who are the types of people that are actually active with digital biomarkers apps and sensors - the people providing the high quality and longitudinal data that this field is being founded upon? Understanding the people behind digital biomarkers, the very people this emerging field aims to help, may actually be the real challenge as well as opportunity for digital biomarkers.

  5. Digital Materials – Evaluation of the Possibilities of using Selected Hyperelastic Models to Describe Constitutive Relations

    Directory of Open Access Journals (Sweden)

    Mańkowski J.

    2017-08-01

    Full Text Available The authors tried to identify the parameters of numerical models of digital materials, which are a kind of composite resulting from the manufacture of the product in 3D printers. With the arrangement of several heads of the printer, the new material can result from mixing of materials with radically different properties, during the process of producing single layer of the product. The new material has properties dependent on the base materials properties and their proportions. Digital materials tensile characteristics are often non-linear and qualify to be described by hyperelastic materials models. The identification was conducted based on the results of tensile tests models, its various degrees coefficients of the polynomials to various degrees coefficients of the polynomials. The Drucker’s stability criterion was also examined. Fourteen different materials were analyzed.

  6. Decision support system for the detection and grading of hard exudates from color fundus photographs

    Science.gov (United States)

    Jaafar, Hussain F.; Nandi, Asoke K.; Al-Nuaimy, Waleed

    2011-11-01

    Diabetic retinopathy is a major cause of blindness, and its earliest signs include damage to the blood vessels and the formation of lesions in the retina. Automated detection and grading of hard exudates from the color fundus image is a critical step in the automated screening system for diabetic retinopathy. We propose novel methods for the detection and grading of hard exudates and the main retinal structures. For exudate detection, a novel approach based on coarse-to-fine strategy and a new image-splitting method are proposed with overall sensitivity of 93.2% and positive predictive value of 83.7% at the pixel level. The average sensitivity of the blood vessel detection is 85%, and the success rate of fovea localization is 100%. For exudate grading, a polar fovea coordinate system is adopted in accordance with medical criteria. Because of its competitive performance and ability to deal efficiently with images of variable quality, the proposed technique offers promising and efficient performance as part of an automated screening system for diabetic retinopathy.

  7. Automated segmentation of geographic atrophy in fundus autofluorescence images using supervised pixel classification.

    Science.gov (United States)

    Hu, Zhihong; Medioni, Gerard G; Hernandez, Matthias; Sadda, Srinivas R

    2015-01-01

    Geographic atrophy (GA) is a manifestation of the advanced or late stage of age-related macular degeneration (AMD). AMD is the leading cause of blindness in people over the age of 65 in the western world. The purpose of this study is to develop a fully automated supervised pixel classification approach for segmenting GA, including uni- and multifocal patches in fundus autofluorescene (FAF) images. The image features include region-wise intensity measures, gray-level co-occurrence matrix measures, and Gaussian filter banks. A [Formula: see text]-nearest-neighbor pixel classifier is applied to obtain a GA probability map, representing the likelihood that the image pixel belongs to GA. Sixteen randomly chosen FAF images were obtained from 16 subjects with GA. The algorithm-defined GA regions are compared with manual delineation performed by a certified image reading center grader. Eight-fold cross-validation is applied to evaluate the algorithm performance. The mean overlap ratio (OR), area correlation (Pearson's [Formula: see text]), accuracy (ACC), true positive rate (TPR), specificity (SPC), positive predictive value (PPV), and false discovery rate (FDR) between the algorithm- and manually defined GA regions are [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], and [Formula: see text], respectively.

  8. Research on Digital Product Modeling Key Technologies of Digital Manufacturing

    Institute of Scientific and Technical Information of China (English)

    DING Guoping; ZHOU Zude; HU Yefa; ZHAO Liang

    2006-01-01

    With the globalization and diversification of the market and the rapid development of Information Technology (IT) and Artificial Intelligence (AI), the digital revolution of manufacturing is coming. One of the key technologies in digital manufacturing is product digital modeling. This paper firstly analyzes the information and features of the product digital model during each stage in the product whole lifecycle, then researches on the three critical technologies of digital modeling in digital manufacturing-product modeling, standard for the exchange of product model data and digital product data management. And the potential signification of the product digital model during the process of digital manufacturing is concluded-product digital model integrates primary features of each stage during the product whole lifecycle based on graphic features, applies STEP as data exchange mechanism, and establishes PDM system to manage the large amount, complicated and dynamic product data to implement the product digital model data exchange, sharing and integration.

  9. Undergraduate Game Degree Programs in the United Kingdom and United States: A Comparison of the Curriculum Planning Process

    Science.gov (United States)

    McGill, Monica M.

    2010-01-01

    Digital games are marketed, mass-produced, and consumed by an increasing number of people and the game industry is only expected to grow. In response, post-secondary institutions in the United Kingdom (UK) and the United States (US) have started to create game degree programs. Though curriculum theorists provide insight into the process of…

  10. Digital discrimination of neutrons and γ-rays in liquid scintillators using pulse gradient analysis

    International Nuclear Information System (INIS)

    D'Mellow, B.; Aspinall, M.D.; Mackin, R.O.; Joyce, M.J.; Peyton, A.J.

    2007-01-01

    A method for the digital discrimination of neutrons and γ-rays in mixed radiation fields is described. Pulses in the time domain, arising from the interaction of photons and neutrons in a liquid scintillator, have been produced using an accepted empirical model and from experimental measurements with an americium-beryllium source. Neutrons and γ-rays have been successfully discriminated in both of these data sets in the digital domain. The digital discrimination method described in this paper is simple and exploits samples early in the life of the pulse. It is thus compatible with current embedded system technologies, offers a degree of immunity to pulse pile-up and heralds a real-time means for neutron/γ discrimination that is fundamental to many potential industrial applications

  11. Digital Pulser for Characterization and Diagnostic of Digital Spectrometers

    International Nuclear Information System (INIS)

    Jordanov, V.T.

    2013-01-01

    The concept and the realization of the digital pulser are presented. The digital pulser is implemented as a functional block of a digital spectrometer. The digital pulser provides noise free and distortion free measurement of the inherent electronic noise of the entire spectroscopy system. The digital pulser is introduced at the end of the signal processing chain and allows separate evaluation of the individual spectroscopy blocks. It offers the ability to characterize and diagnose problems of the digital pulse height analysers by grounding their inputs. The digital pulser does not interfere with the processing of the detector signals and does not contribute to the dead time and the pulse pile-up of the system. The digital pulser peaks are not affected by the presence of detector pulses and are stored in a separate histogram memory leaving the detector spectrum undistorted. (author)

  12. Digital Ethics/Going Digital.

    Science.gov (United States)

    Wilson, Bradley

    1996-01-01

    Finds that the recent National Press Photographers Association code of ethics can serve as a model for any photography staff. Discusses how digital imaging is becoming commonplace in classrooms, due to decreasing costs and easier software. Explains digital terminology. Concludes that time saved in the darkroom and at the printer is now spent on…

  13. Digital mapping in extreme and remote environments

    Science.gov (United States)

    Andersson, Joel; Bauer, Tobias; Sarlus, Zimer; Zainy, Maher; Brethes, Anais

    2017-04-01

    During the last few years, Luleå University of Technology has performed a series of research projects in remote areas with extreme climatic conditions using digital mapping technologies. The majority of past and ongoing research projects focus on the arctic regions of the Fennoscandian Shield and Greenland but also on the Zagros fold-and-thrust belt in northern Iraq. Currently, we use the Midland Valley application FieldMove on iPad mini devices with ruggedized casings. As all projects have a strong focus on geological field work, harsh climatic conditions are a challenge not only for the geologists but also for the digital mapping hardware. In the arctic regions especially cold temperatures affect battery lifetime and performance of the screens. But also high temperatures are restricting digital mapping. From experience, a typical temperature range where digital mapping, using iPad tablets, is possible lies between -20 and +40 degrees. Furthermore, the remote character of field areas complicates access but also availability of electricity. By a combination of robust solar chargers and ruggedized batteries we are able to work entirely autarkical. Additionally, we are currently installing a drone system that allows us to map outcrops normally inaccessible because of safety reasons or time deficiency. The produced data will subsequently be taken into our Virtual Reality studio for interpretation and processing. There we will be able to work also with high resolution DEM data from Lidar scanning allowing us to interpret structural features such as post-glacial faults in areas that are otherwise only accessible by helicopter. By combining digital field mapping with drone technique and a Virtual Reality studio we are able to work in hardly accessible areas, improve safety during field work and increase efficiency substantially.

  14. Can We Teach Digital Natives Digital Literacy?

    Science.gov (United States)

    Ng, Wan

    2012-01-01

    In recent years, there has been much debate about the concept of digital natives, in particular the differences between the digital natives' knowledge and adoption of digital technologies in informal versus formal educational contexts. This paper investigates the knowledge about educational technologies of a group of undergraduate students…

  15. The system Cu-Rh-S at 900 degrees, 700 degrees, 540 degrees and 500 degrees C

    DEFF Research Database (Denmark)

    Karup-Møller, Sven; Makovicky, E.

    2007-01-01

    Phase relations in the dry condensed system Cu-Rh-S were determined at 900, 700, 540 and 500 degrees C. At 900 degrees C, the system contains digenite, four rhodium sulfides (Rh17S15, Rh3S4, Rh2S3 and RhS similar to 3), three ternary sulfides (CuRh2S4, CuxRhS3+x and a fibrous sulfide in the range...

  16. FERMI: a digital Front End and Readout MIcrosystem for high resolution calorimetry

    International Nuclear Information System (INIS)

    Alexanian, H.; Appelquist, G.; Bailly, P.

    1995-01-01

    We present a digital solution for the front-end electronics of high resolution calorimeters at future colliders. It is based on analogue signal compression, high speed A/D converters, a fully programmable pipeline and a digital signal processing (DSP) chain with local intelligence and system supervision. This digital solution is aimed at providing maximal front-end processing power by performing waveform analysis using DSP methods. For the system integration of the multichannel device a multi-chip, silicon-on-silicon multi-chip module (MCM) has been adopted. This solution allows a high level of integration of complex analogue and digital functions, with excellent flexibility in mixing technologies for the different functional blocks. This type of multichip integration provides a high degree of reliability and programmability at both the function and the system level, with the additional possibility of customising the microsystem to detector-specific requirements. For enhanced reliability in high radiation environments, fault tolerance strategies, i.e. redundancy, reconfigurability, majority voting and coding for error detection and correction, are integrated into the design. ((orig.))

  17. Principle Research on a Single Mass Piezoelectric Six-Degrees-of-Freedom Accelerometer

    Directory of Open Access Journals (Sweden)

    Jingcheng Liu

    2013-08-01

    Full Text Available A signal mass piezoelectric six-degrees-of-freedom (six-DOF accelerometer is put forward in response to the need for health monitoring of the dynamic vibration characteristics of high grade digitally controlled machine tools. The operating principle of the piezoelectric six-degrees-of-freedom accelerometer is analyzed, and its structure model is constructed. The numerical simulation model (finite element model of the six axis accelerometer is established. Piezoelectric quartz is chosen for the acceleration sensing element and conversion element, and its static sensitivity, static coupling interference and dynamic natural frequency, dynamic cross coupling are analyzed by ANSYS software. Research results show that the piezoelectric six-DOF accelerometer has advantages of simple and rational structure, correct sensing principle and mathematic model, good linearity, high rigidity, and theoretical natural frequency is more than 25 kHz, no nonlinear cross coupling and no complex decoupling work.

  18. The life cycle of the Book of the Dead as a Digital Humanities resource

    Directory of Open Access Journals (Sweden)

    Ulrike Henny

    2017-11-01

    Full Text Available This contribution tracks and analyzes the life cycle of the Book of the Dead as a digital project and a rather complex research resource. It gives an account of how the digital archive “Das altägyptische Totenbuch – Ein digitales Textzeugenarchiv” was constructed in the context of the digitization efforts of the Academy for Science of North Rhine-Westphalia. From the beginning, the design of the archive has factored in a life of the digital archive beyond its funding period and has sighted to create a sustainable information resource. The main issues to be discussed here are what experiences have been made with sustainability, use and reuse of the Book of the Dead archive since the official end of the project in December 2012, with a focus on conceptual, technical and organizational aspects. The lessons learned can be of interest for future undertakings in the creation of XML and web-based digital platforms in Digital Classics and beyond. In a nutshell, they are: (a the importance of wary technological choices in an initial phase cannot be underestimated, (b the application and presentation layers of a digital resource, if present, are an essential part of it, (c a certain degree of commitment from the research community and funding bodies alike is indispensable for maintaining a web-based complex Digital Humanities resource.

  19. Variable self-powered light detection CMOS chip with real-time adaptive tracking digital output based on a novel on-chip sensor.

    Science.gov (United States)

    Wang, HongYi; Fan, Youyou; Lu, Zhijian; Luo, Tao; Fu, Houqiang; Song, Hongjiang; Zhao, Yuji; Christen, Jennifer Blain

    2017-10-02

    This paper provides a solution for a self-powered light direction detection with digitized output. Light direction sensors, energy harvesting photodiodes, real-time adaptive tracking digital output unit and other necessary circuits are integrated on a single chip based on a standard 0.18 µm CMOS process. Light direction sensors proposed have an accuracy of 1.8 degree over a 120 degree range. In order to improve the accuracy, a compensation circuit is presented for photodiodes' forward currents. The actual measurement precision of output is approximately 7 ENOB. Besides that, an adaptive under voltage protection circuit is designed for variable supply power which may undulate with temperature and process.

  20. When Graduate Degrees Prostitute the Educational Process: Degrees Gone Wild

    Science.gov (United States)

    Lumadue, Richard T.

    2006-01-01

    Graduate degrees prostitute the educational process when they are sold to consumers by unaccredited degree/diploma mills as being equivalent to legitimate, bona-fide degrees awarded by accredited graduate schools. This article carefully analyzes the serious problems of bogus degrees and their association with the religious higher education…

  1. Advanced Digitization Techniques in Retrieval of Mechanism and Machine Science Resources

    Science.gov (United States)

    Lovasz, E.-Ch.; Gruescu, C. M.; Ciupe, V.; Carabas, I.; Margineanu, D.; Maniu, I.; Dehelean, N.

    The European project thinkMOTION works on the purpose of retrieving all-times content regarding mechanisms and machine science by means of creating a digital library, accessible to a broad public through the portal Europeana. DMG-Lib is intended to display the development in the field, from its very beginning up to now days. There is a large range of significant objects available, physically very heterogeneous and needing all to be digitized. The paper presents the workflow, the equipments and specific techniques used in digitization of documents featuring very different characteristics (size, texture, color, degree of preservation, resolution and so on). Once the workflow established on very detailed steps, the development of the workstation is treated. Special equipments designed and assembled at Universitatea "Politehnica" Timisoara are presented. A large series of software applications, including original programs, work for digitization itself, processing of images, management of files, automatic optoelectronic control of capture, storage of information in different stages of processing. An illustrating example is explained, showing the steps followed in order to obtain a clear, high-resolution image from an old original document (very valuable as a historical proof but very poor in quality regarding clarity, contrast and resolution).

  2. Digitization and digital archiving a practical guide for librarians

    CERN Document Server

    Leggett, Elizabeth R

    2014-01-01

    Modern library patrons are embracing the ease with which information can be accessed digitally, and so many librarians are currently working toward making information available electronically. Digitization and Digital Archiving: A Practical Guide for Librarians is a comprehensive guide with step-by-step instructions for forming digital archives.

  3. Digital disruption ?syndromes.

    Science.gov (United States)

    Sullivan, Clair; Staib, Andrew

    2017-05-18

    The digital transformation of hospitals in Australia is occurring rapidly in order to facilitate innovation and improve efficiency. Rapid transformation can cause temporary disruption of hospital workflows and staff as processes are adapted to the new digital workflows. The aim of this paper is to outline various types of digital disruption and some strategies for effective management. A large tertiary university hospital recently underwent a rapid, successful roll-out of an integrated electronic medical record (EMR). We observed this transformation and propose several digital disruption "syndromes" to assist with understanding and management during digital transformation: digital deceleration, digital transparency, digital hypervigilance, data discordance, digital churn and post-digital 'depression'. These 'syndromes' are defined and discussed in detail. Successful management of this temporary digital disruption is important to ensure a successful transition to a digital platform. What is known about this topic? Digital disruption is defined as the changes facilitated by digital technologies that occur at a pace and magnitude that disrupt established ways of value creation, social interactions, doing business and more generally our thinking. Increasing numbers of Australian hospitals are implementing digital solutions to replace traditional paper-based systems for patient care in order to create opportunities for improved care and efficiencies. Such large scale change has the potential to create transient disruption to workflows and staff. Managing this temporary disruption effectively is an important factor in the successful implementation of an EMR. What does this paper add? A large tertiary university hospital recently underwent a successful rapid roll-out of an integrated electronic medical record (EMR) to become Australia's largest digital hospital over a 3-week period. We observed and assisted with the management of several cultural, behavioural and

  4. The First Data Release of the Sloan Digital Sky Survey

    CERN Document Server

    Abazajian, Kevork; Agüeros, Marcel A.; Allam, Sahar S.; Anderson, Scott F.; Annis, James; Bahcall, Neta A.; Baldry, Ivan K.; Bastian, Steven; AndreasBerlind; Bernardi, Mariangela; Blanton, Michael R.; Blythe, Norman; Bochanski, John J.; Boroski, William N.; Brewington, Howard; Briggs, John W.; Brinkmann, J.; Brunner, Robert J.; Budavari, Tamas; Carey, Larry N.; Carr, Michael A.; Castander, Francisco J.; Chiu, Kuenley; Collinge, Matthew J.; Connolly, A. J.; Covey, Kevin R.; Csabai, István; J.Dalcanton, Julianne; Dodelson, Scott; Doi, Mamoru; Dong, Feng; Eisenstein, Daniel J.; L.Evans, Michael; Fan, Xiaohui; Feldman, Paul D.; Finkbeiner, Douglas P.; Friedman, Scott D.; Frieman, JoshuaA.; Fukugita, Masataka; Gal, Roy R.; Gillespie, Bruce; Glazebrook, Karl; F.Gonzalez, Carlos; Gray, Jim; Grebel, Eva K.; Grodnicki, Lauren; Gunn, James E.; K.Gurbani, Vijay; Hall, Patrick B.; Hao, Lei; Harbeck, Daniel; Harris, Frederick H.; C.Harris, Hugh; Harvanek, Michael; Hawley, Suzanne L.; Heckman, Timothy M.; Helmboldt, J. F.; Hendry, John S.; Hennessy, Gregory S.; Hindsley, Robert B.; Hogg, David W.; J.Holmgren, Donald; Holtzman, Jon A.; Homer, Lee; Hui, Lam; Ichikawa, Shin-ichi; Ichikawa, Takashi; Inkmann, John P.; ˇ, Zeljko Ivezíc; Jester, Sebastian; Johnston, David E.; Jordan, Beatrice; Jordan, Wendell P.; Jorgensen, Anders M.; Juríc, Mario; Kauffmann, Guinevere; M.Kent, Stephen; Kleinman, S. J.; Knapp, G. R.; Kniazev, Alexei Yu.; Kron, Richard G.; JurekKrzesinski; Kunszt, Peter Z.; Kuropatkin, Nickolai; Lamb, Donald Q.; Lampeitl, Hubert; Laubscher, Bryan E.; Lee, Brian C.; Leger, R. French; Li, Nolan; Lidz, Adam; Lin, Huan; Loh, Yeong-Shang; Long, Daniel C.; Loveday, Jon; Lupton, Robert H.; Malik, Tanu; BruceMargon; McGehee, Peregrine M.; McKay, Timothy A.; Meiksin, Avery; A.Miknaitis, Gajus; Moorthy, Bhasker K.; Munn, Jeffrey A.; Murphy, Tara; Nakajima, Reiko; Narayanan, VijayK.; Nash, Thomas; Neilsen, Eric H. Jr.; Newberg, Heidi Jo; Newman, Peter R.; Nichol, Robert C.; Nicinski, Tom; Nieto-Santisteban, Maria; Nitta, Atsuko; MichaelOdenkirchen; Okamura, Sadanori; Ostriker, Jeremiah P.; Owen, Russell; NikhilPadmanabhan; Peoples, John; Pier, Jeffrey R.; Pindor, Bartosz; Pope, Adrian C.; R.Quinn, Thomas; Rafikov, R. R.; Raymond, Sean N.; Richards, Gordon T.; Richmond, Michael W.; Rix, Hans-Walter; Rockosi, Constance M.; Schaye, Joop; Schlegel, David J.; P.Schneider, Donald; Schroeder, Joshua; Scranton, Ryan; Sekiguchi, Maki; Seljak, Uros; Sergey, Gary; Sesar, Branimir; Sheldon, Erin; Shimasaku, Kazu; Siegmund, Walter A.; Silvestri, Nicole M.; Sinisgalli, Allan J.; Sirko, Edwin; Smith, J. Allyn; Smolčíc, Vernesa; Snedden, Stephanie A.; Stebbins, Albert; Steinhardt, Charles; Stinson, Gregory; Stoughton, Chris; Strateva, Iskra V.; Strauss, Michael A.; SubbaRao, Mark; Szalay, Alexander S.; Szapudi, István; Szkody, Paula; Tasca, Lidia; Tegmark, Max; Thakar, Aniruddha R.; Tremonti, Christy; Tucker, Douglas L.; Uomoto, Alan; Vanden Berk, Daniel E.; Vandenberg, Jan; Vogeley, Michael S.; WolfgangVoges; Vogt, Nicole P.; Walkowicz, Lucianne M.; Weinberg, David H.; West, Andrew A.; White, Simon D.M.; Wilhite, Brian C.; Willman, Beth; Xu, Yongzhong; Yanny, Brian; JeanYarger; Yasuda, Naoki; Yip, Ching-Wa; Yocum, D. R.; York, Donald G.; L.Zakamska, Nadia; Zehavi, Idit; Zheng, Wei; Zibetti, Stefano; Zucker, Daniel B.

    2003-01-01

    The Sloan Digital Sky Survey has validated and made publicly available its First Data Release. This consists of 2099 square degrees of five-band (u, g, r, i, z) imaging data, 186,240 spectra of galaxies, quasars, stars and calibrating blank sky patches selected over 1360 square degrees of this area, and tables of measured parameters from these data. The imaging data go to a depth of r ~ 22.6 and are photometrically and astrometrically calibrated to 2% rms and 100 milli-arcsec rms per coordinate, respectively. The spectra cover the range 3800--9200 A, with a resolution of 1800--2100. Further characteristics of the data are described, as are the data products themselves.

  5. Digital Natives and Digital Divide: Analysing Perspective for Emerging Pedagogy

    Science.gov (United States)

    Onye, Uriel U.; Du, Yunfei

    2016-01-01

    This paper addresses the concepts of digital natives and digital divide from the perspective of the digital outsiders (part of digital natives). It takes a critical look at the implications of available ICT in both developed and underdeveloped countries in the fight against digital divide. The major contribution to literature is by drawing…

  6. Digital subtraktion

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder

    2004-01-01

    Digital subtraktion er en metode til at fjerne uønskede oplysninger i et røntgenbillede. Subtraktionsteknikken bruges primært i forbindelse med angiografi hvor man kun er interesseret i at se selve karret. Derfor er digital subtraktion i daglig tale synonymt med DSA eller DVI – hhv. Digital...... Subtraction Angiography eller Digital Vascular Imaging. Benævnelserne er to røntgenfirmaers navn for den samme teknik. Digital subtraktion kræver speciel software, samt at apparaturet kan eksponere i serier....

  7. REVIEW OF NRC APPROVED DIGITAL CONTROL SYSTEMS ANALYSIS

    International Nuclear Information System (INIS)

    Markman, D.W.

    1999-01-01

    Preliminary design concepts for the proposed Subsurface Repository at Yucca Mountain indicate extensive reliance on modern, computer-based, digital control technologies. The purpose of this analysis is to investigate the degree to which the U. S. Nuclear Regulatory Commission (NRC) has accepted and approved the use of digital control technology for safety-related applications within the nuclear power industry. This analysis reviews cases of existing digitally-based control systems that have been approved by the NRC. These cases can serve as precedence for using similar types of digitally-based control technologies within the Subsurface Repository. While it is anticipated that the Yucca Mountain Project (YMP) will not contain control systems as complex as those required for a nuclear power plant, the review of these existing NRC approved applications will provide the YMP with valuable insight into the NRCs review process and design expectations for safety-related digital control systems. According to the YMP Compliance Program Guidance, portions of various NUREGS, Regulatory Guidelines, and nuclear IEEE standards the nuclear power plant safety related concept would be applied to some of the designs on a case-by-case basis. This analysis will consider key design methods, capabilities, successes, and important limitations or problems of selected control systems that have been approved for use in the Nuclear Power industry. An additional purpose of this analysis is to provide background information in support of further development of design criteria for the YMP. The scope and primary objectives of this analysis are to: (1) Identify and research the extent and precedence of digital control and remotely operated systems approved by the NRC for the nuclear power industry. Help provide a basis for using and relying on digital technologies for nuclear related safety critical applications. (2) Identify the basic control architecture and methods of key digital control

  8. Optical design considerations when imaging the fundus with an adaptive optics correction

    Science.gov (United States)

    Wang, Weiwei; Campbell, Melanie C. W.; Kisilak, Marsha L.; Boyd, Shelley R.

    2008-06-01

    Adaptive Optics (AO) technology has been used in confocal scanning laser ophthalmoscopes (CSLO) which are analogous to confocal scanning laser microscopes (CSLM) with advantages of real-time imaging, increased image contrast, a resistance to image degradation by scattered light, and improved optical sectioning. With AO, the instrumenteye system can have low enough aberrations for the optical quality to be limited primarily by diffraction. Diffraction-limited, high resolution imaging would be beneficial in the understanding and early detection of eye diseases such as diabetic retinopathy. However, to maintain diffraction-limited imaging, sufficient pixel sampling over the field of view is required, resulting in the need for increased data acquisition rates for larger fields. Imaging over smaller fields may be a disadvantage with clinical subjects because of fixation instability and the need to examine larger areas of the retina. Reduction in field size also reduces the amount of light sampled per pixel, increasing photon noise. For these reasons, we considered an instrument design with a larger field of view. When choosing scanners to be used in an AOCSLO, the ideal frame rate should be above the flicker fusion rate for the human observer and would also allow user control of targets projected onto the retina. In our AOCSLO design, we have studied the tradeoffs between field size, frame rate and factors affecting resolution. We will outline optical approaches to overcome some of these tradeoffs and still allow detection of the earliest changes in the fundus in diabetic retinopathy.

  9. Digital Citizenship Means Character Education for the Digital Age

    Science.gov (United States)

    Ohler, Jason

    2012-01-01

    The reality of students' cyber lives has thrust upon educators a new approach: creating character education programs tuned to digital youth that are proactive and aggressive. This will help integrate students' digital activities within the context of the communities in which they live, both local and digital. The digital age beckons a new era of…

  10. Retinal pigment epithelial detachments and tears, and progressive retinal degeneration in light chain deposition disease.

    Science.gov (United States)

    Spielberg, Leigh H; Heckenlively, John R; Leys, Anita M

    2013-05-01

    Light-chain deposition disease (LCDD) is a rare condition characterised by deposition of monoclonal immunoglobulin light chains (LCs) in tissues, resulting in varying degrees of organ dysfunction. This study reports the characteristic clinical ocular findings seen in advanced LCDD upon development of ocular fundus changes. This is the first report to describe this entity in vivo in a series of patients. A case series of ocular fundus changes in three patients with kidney biopsy-proven LCDD. All patients underwent best corrected visual acuity (BCVA) exam, perimetry, colour fundus photography and fluorescein angiography; two patients underwent indocyanine green angiography, optical coherence tomography, ultrasound and electroretinography; and one patient underwent fundus autofluorescence. Three patients, 53-60 years old at initial presentation, were studied. All three presented with night blindness, poor dark adaptation, metamorphopsia and visual loss. Examination revealed serous and serohaemorrhagic detachments, multiple retinal pigment epithelial (RPE) tears, diffuse RPE degeneration and progressive fibrotic changes. Neither choroidal neovascularisation nor other vascular abnormalities were present. Final best corrected visual acuity (BCVA) ranged from 20/40 to 20/300. Progressive LC deposition in the fundus seems to damage RPE pump function with flow disturbance between choroid and retina. This pathogenesis can explain the evolution to RPE detachments and subsequent rips and progressive retinal malfunction.

  11. Digital surfaces and hydrogeologic data for the Floridan aquifer system in Florida and in parts of Georgia, Alabama, and South Carolina

    Science.gov (United States)

    Bellino, Jason C.

    2011-01-01

    A digital dataset for the Floridan aquifer system in Florida and in parts of Georgia, Alabama, and South Carolina was developed from selected reports published as part of the Regional Aquifer-System Analysis (RASA) Program of the U.S. Geological Survey (USGS) in the 1980s. These reports contain maps and data depicting the extent and elevation of both time-stratigraphic and hydrogeologic units of which the aquifer system is composed, as well as data on hydrology, meteorology, and aquifer properties. The three primary reports used for this dataset compilation were USGS Professional Paper 1403-B (Miller, 1986), Professional Paper 1403-C (Bush and Johnston, 1988), and USGS Open-File Report 88-86 (Miller, 1988). Paper maps from Professional Papers 1403-B and 1403-C were scanned and georeferenced to the North American Datum of 1927 (NAD27) using the Lambert Conformal Conic projection (standard parallels 33 and 45 degrees, central longitude -96 degrees, central latitude 39 degrees). Once georeferenced, tracing of pertinent line features contained in each image (for example, contours and faults) was facilitated by specialized software using algorithms that automated much of the process. Resulting digital line features were then processed using standard geographic information system (GIS) software to remove artifacts from the digitization process and to verify and update attribute tables. The digitization process for polygonal features (for example, outcrop areas and unit extents) was completed by hand using GIS software.

  12. Digital Insights

    DEFF Research Database (Denmark)

    Knudsen, Gry Høngsmark

    , by incorporating media as both channel, frame, and apparatus for advertising response, the dissertation brings into attention that more aspects than the text-reader relationship influence ad response. Finally, the dissertation proposes the assemblage approach for exploring big data in consumer culture research...... and practices with digital media, when they meet and interpret advertising. Through studies of advertising response on YouTube and experiments with consumers’ response to digitally manipulated images, the dissertation shows how digital media practices facilitate polysemic and socially embedded advertising......This dissertation forwards the theory of digital consumer-response as a perspective to examine how digital media practices influence consumers’ response to advertising. Digital consumer-response is a development of advertising theory that encompasses how consumers employ their knowledge...

  13. Second-degree discrete Painleve equations conceal first-degree ones

    International Nuclear Information System (INIS)

    Ramani, A; Grammaticos, B; Joshi, N

    2010-01-01

    We examine various second-degree difference equations which have been proposed over the years and according to their authors' claims should be integrable. This study is motivated by the fact that we consider that second-degree discrete systems cannot be integrable due to the proliferation of the images (and pre-images) of the initial point. We show that in the present cases no contradiction exists. In all cases examined, we show that there exists an underlying integrable first-degree mapping which allows us to obtain an appropriate solution of the second-degree one.

  14. Digital information culture the individual and society in the digital age

    CERN Document Server

    Tredinnick, Luke

    2008-01-01

    Digital Information Culture is an introduction to the cultural, social and political impact of digital information and digital resources. The book is organised around themes, rather than theories and is arranged into three sections: culture, society and the individual. Each explores key elements of the social, cultural and political impact of digital information. The culture section outlines the origins of cyber culture in fifties pulp-fiction through to the modern day. It explores the issues of information overload, the threat of a digital dark age, and the criminal underbelly of digital culture. Section two, society, explores the economic and social impact of digital information, outlining key theories of the Information Age. Section three explores the impact of digital information and digital resources on the individual, exploring the changing nature of identity in a digital world. Written by a leading author in the field Focuses on digital information and its social, cultural and political impact is uniqu...

  15. Digital printing

    Science.gov (United States)

    Sobotka, Werner K.

    1997-02-01

    Digital printing is described as a tool to replace conventional printing machines completely. Still this goal was not reached until now with any of the digital printing technologies to be described in the paper. Productivity and costs are still the main parameters and are not really solved until now. Quality in digital printing is no problem anymore. Definition of digital printing is to transfer digital datas directly on the paper surface. This step can be carried out directly or with the use of an intermediate image carrier. Keywords in digital printing are: computer- to-press; erasable image carrier; image carrier with memory. Digital printing is also the logical development of the new digital area as it is pointed out in Nicholas Negropotes book 'Being Digital' and also the answer to networking and Internet technologies. Creating images text and color in one country and publishing the datas in another country or continent is the main advantage. Printing on demand another big advantage and last but not least personalization the last big advantage. Costs and being able to coop with this new world of prepress technology is the biggest disadvantage. Therefore the very optimistic growth rates for the next few years are really nonexistent. The development of complete new markets is too slow and the replacing of old markets is too small.

  16. Digital squares

    DEFF Research Database (Denmark)

    Forchhammer, Søren; Kim, Chul E

    1988-01-01

    Digital squares are defined and their geometric properties characterized. A linear time algorithm is presented that considers a convex digital region and determines whether or not it is a digital square. The algorithm also determines the range of the values of the parameter set of its preimages....... The analysis involves transforming the boundary of a digital region into parameter space of slope and y-intercept...

  17. Digital skrivedidaktik

    DEFF Research Database (Denmark)

    Digital skrivedidaktik består af to dele. Første del præsenterer teori om skrivekompetence og digital skrivning. Digital skrivning er karakteriseret ved at tekster skrives på computer og med digitale værktøjer, hvilket ændrer skrivningens traditionelle praksis, produkt og processer. Hvad er digital...... om elevens skriveproces) og Blogskrivning (der styrker eleverne i at bruge blogs i undervisningen)....

  18. Cost Model for Digital Curation: Cost of Digital Migration

    DEFF Research Database (Denmark)

    Kejser, Ulla Bøgvad; Nielsen, Anders Bo; Thirifays, Alex

    2009-01-01

    The Danish Ministry of Culture is currently funding a project to set up a model for costing preservation of digital materials held by national cultural heritage institutions. The overall objective of the project is to provide a basis for comparing and estimating future financial requirements...... for digital preservation and to increase cost effectiveness of digital preservation activities. In this study we describe an activity based costing methodology for digital preservation based on the OAIS Reference Model. In order to estimate the cost of digital migrations we have identified cost critical...

  19. Digital preservation

    CERN Document Server

    Deegan, Marilyn

    2013-01-01

    Digital preservation is an issue of huge importance to the library and information profession right now. With the widescale adoption of the internet and the rise of the world wide web, the world has been overwhelmed by digital information. Digital data is being produced on a massive scale by individuals and institutions: some of it is born, lives and dies only in digital form, and it is the potential death of this data, with its impact on the preservation of culture, that is the concern of this book. So how can information professionals try to remedy this? Digital preservation is a complex iss

  20. Effect of green tea on the second degree burn wounds in rats

    Directory of Open Access Journals (Sweden)

    Mohammad Javad Fatemi

    2014-01-01

    Full Text Available Background: Various studies indicate that the green tea has anti-inflammatory and anti-oxidative properties. Moreover, a few studies have been carried out that demonstrate beneficial effects of green tea on burned patients. Materials and Methods: In this study, green tea, Vaseline, and silver sulfadiazine dressings were used as first-aid treatment to deep dermal contact burns in rats, compared with a control of nothing. After creating second-degree burn on the dorsum of rats, the treatments were applied for 15 min in four groups. Wound dressing changes were daily. Macroscopic study was performed on days 1, 3, 7, and 14 by using a digital camera and software processing of photos. Microscopic examination was done by pathologic evaluation of skin specimens on day 14. Results: We observed that green tea usage significantly decreased burn size in comparison to the control group (P = 0.004. Conclusion: Green tea is effective on healing process of second degree burn wounds.

  1. Exudate-based diabetic macular edema detection in fundus images using publicly available datasets

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Meriaudeau, Fabrice [ORNL; Karnowski, Thomas Paul [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK); Garg, Seema [University of North Carolina; Tobin Jr, Kenneth William [ORNL; Chaum, Edward [University of Tennessee, Knoxville (UTK)

    2011-01-01

    Diabetic macular edema (DME) is a common vision threatening complication of diabetic retinopathy. In a large scale screening environment DME can be assessed by detecting exudates (a type of bright lesions) in fundus images. In this work, we introduce a new methodology for diagnosis of DME using a novel set of features based on colour, wavelet decomposition and automatic lesion segmentation. These features are employed to train a classifier able to automatically diagnose DME through the presence of exudation. We present a new publicly available dataset with ground-truth data containing 169 patients from various ethnic groups and levels of DME. This and other two publicly available datasets are employed to evaluate our algorithm. We are able to achieve diagnosis performance comparable to retina experts on the MESSIDOR (an independently labelled dataset with 1200 images) with cross-dataset testing (e.g., the classifier was trained on an independent dataset and tested on MESSIDOR). Our algorithm obtained an AUC between 0.88 and 0.94 depending on the dataset/features used. Additionally, it does not need ground truth at lesion level to reject false positives and is computationally efficient, as it generates a diagnosis on an average of 4.4 s (9.3 s, considering the optic nerve localization) per image on an 2.6 GHz platform with an unoptimized Matlab implementation.

  2. Digital academia: How higher education is affected by digital technology

    OpenAIRE

    Eriksmo, Anton; Sundberg, Johan

    2016-01-01

    Digital technology in higher education is constantly evolving. Understanding the effects of digital technology is important for higher education institutions in order to make good investments of digital technology. Previous research has focused on learning, teaching or the organization and the relation between one of these aspects and digital technology, thereby missing a broader understanding of how materiality in digital technology affects higher education. In this study themed interviews w...

  3. Digital rights management for digital cinema

    Science.gov (United States)

    Kirovski, Darko; Peinado, Marcus; Petitcolas, Fabien A. P.

    2001-12-01

    There is a wide consensus among the feature film production studios that the Internet era brings a new paradigm for film distribution to cinemas worldwide. The benefits of digital cinema to both producers and cinemas are numerous: significantly lower distribution and maintenance costs, immediate access to film libraries, higher presentation quality, and strong potential for developing new business models. Despite these advantages, the studios are still reluctant to jump into the digital age. The main showstopper for digital cinema is the danger of widespread piracy. Piracy already costs Hollywood an estimated two billion dollars annually and digital cinema without proper copyright enforcement could increase this number. In this paper, we present a copyright management system that aims at providing the set of necessary security tools: standard cryptographic primitives and copyright protection mechanisms that enable a reliable and secure feature film delivery system.

  4. Cognitive Hacking and Digital Government: Digital Identity

    Directory of Open Access Journals (Sweden)

    Paul Thompson

    2004-04-01

    Full Text Available Recently the National Center for Digital Government held a workshop on "The Virtual Citizen: Identity, Autonomy, and Accountability: A Civic Scenario Exploration of the Role of Identity in On-Line. Discussions at the workshop focused on five scenarios for future authentication policies with respect to digital identity. The underlying technologies considered for authentication were: biometrics: cryptography, with a focus on digital signatures; secure processing/computation; and reputation systems. Most discussion at the workshop focused on issues related to authentication of users of digital government, but, as implied by the inclusion of a scenario related to ubiquitous identity theft, there was also discussion of problems related to misinformation, including cognitive hacking. Cognitive hacking refers to a computer or information system attack that relies on changing human users' perceptions and corresponding behaviors in order to succeed. This paper describes cognitive hacking, suggests countermeasures, and discusses the implications of cognitive hacking for identity in digital government. In particular, spoofing of government websites and insider misuse are considered.

  5. Refocusing criterion via sparsity measurements in digital holography.

    Science.gov (United States)

    Memmolo, Pasquale; Paturzo, Melania; Javidi, Bahram; Netti, Paolo A; Ferraro, Pietro

    2014-08-15

    Several automatic approaches have been proposed in the past to compute the refocus distance in digital holography (DH). However most of them are based on a maximization or minimization of a suitable amplitude image contrast measure, regarded as a function of the reconstruction distance parameter. Here we show that, by using the sparsity measure coefficient regarded as a refocusing criterion in the holographic reconstruction, it is possible to recover the focus plane and, at the same time, establish the degree of sparsity of digital holograms, when samples of the diffraction Fresnel propagation integral are used as a sparse signal representation. We employ a sparsity measurement coefficient known as Gini's index thus showing for the first time, to the best of our knowledge, its application in DH, as an effective refocusing criterion. Demonstration is provided for different holographic configurations (i.e., lens and lensless apparatus) and for completely different objects (i.e., a thin pure phase microscopic object as an in vitro cell, and macroscopic puppets) preparation.

  6. Optical coherence tomography and fundus autofluorescence findings in presumed congenital simple retinal pigment epithelium hamartoma

    Directory of Open Access Journals (Sweden)

    Baskaran, Prabu

    2017-10-01

    Full Text Available Aim: Presumed congenital simple retinal pigment epithelium hamartoma is a rare benign lesion of the macula that mimics congenital hypertrophy of the retinal pigment epithelium (RPE and combined hamartoma of the retina and the RPE; newer imaging modalities can help in diagnosis. We report three patients with presumed congenital simple RPE hamartoma, and describe the enhanced-depth imaging optical coherence tomography (EDI-OCT and fundus autofluorescence (FAF findings. Methods: Two patients were asymptomatic; one had an intraocular foreign body in addition to the hamartoma. All had a similar jet black, elevated lesion in the macula, sparing the fovea. EDI-OCT showed a characteristic hyperreflective layer with complete optical shadowing of the deeper layers; FAF showed pronounced hypoautofluorescence of the lesion. Conclusion: Multimodal imaging with FAF and EDI-OCT can help to differentiate simple RPE hamartoma from similar RPE lesions, and may serve as a useful adjunct to clinical diagnosis of this rare tumor. We present the second largest series of presumed congenital simple RPE hamartoma, and – to the best of our knowledge – the first report of FAF findings of this tumor.

  7. Cognitive Hacking and Digital Government: Digital Identity

    OpenAIRE

    Paul Thompson

    2004-01-01

    Recently the National Center for Digital Government held a workshop on "The Virtual Citizen: Identity, Autonomy, and Accountability: A Civic Scenario Exploration of the Role of Identity in On-Line. Discussions at the workshop focused on five scenarios for future authentication policies with respect to digital identity. The underlying technologies considered for authentication were: biometrics: cryptography, with a focus on digital signatures; secure processing/computation; and reputation syst...

  8. Digital Natives and Digital Immigrants: Teaching with Technology

    Science.gov (United States)

    Martin, Ellen Marie Peterson

    2011-01-01

    Education is witnessing an increasing demand for technology use in the classroom. At the same time, new teachers are entering the profession in high numbers, some being labeled as "Digital Natives" while others are labeled "Digital Immigrants". This qualitative case study investigated the technology practices of Digital Native and Digital…

  9. [Constructing 3-dimensional colorized digital dental model assisted by digital photography].

    Science.gov (United States)

    Ye, Hong-qiang; Liu, Yu-shu; Liu, Yun-song; Ning, Jing; Zhao, Yi-jiao; Zhou, Yong-sheng

    2016-02-18

    To explore a method of constructing universal 3-dimensional (3D) colorized digital dental model which can be displayed and edited in common 3D software (such as Geomagic series), in order to improve the visual effect of digital dental model in 3D software. The morphological data of teeth and gingivae were obtained by intra-oral scanning system (3Shape TRIOS), constructing 3D digital dental models. The 3D digital dental models were exported as STL files. Meanwhile, referring to the accredited photography guide of American Academy of Cosmetic Dentistry (AACD), five selected digital photographs of patients'teeth and gingivae were taken by digital single lens reflex camera (DSLR) with the same exposure parameters (except occlusal views) to capture the color data. In Geomagic Studio 2013, after STL file of 3D digital dental model being imported, digital photographs were projected on 3D digital dental model with corresponding position and angle. The junctions of different photos were carefully trimmed to get continuous and natural color transitions. Then the 3D colorized digital dental model was constructed, which was exported as OBJ file or WRP file which was a special file for software of Geomagic series. For the purpose of evaluating the visual effect of the 3D colorized digital model, a rating scale on color simulation effect in views of patients'evaluation was used. Sixteen patients were recruited and their scores on colored and non-colored digital dental models were recorded. The data were analyzed using McNemar-Bowker test in SPSS 20. Universal 3D colorized digital dental model with better color simulation was constructed based on intra-oral scanning and digital photography. For clinical application, the 3D colorized digital dental models, combined with 3D face images, were introduced into 3D smile design of aesthetic rehabilitation, which could improve the patients' cognition for the esthetic digital design and virtual prosthetic effect. Universal 3D colorized

  10. Object-Oriented Wavelet-Layered Digital Watermarking Technique

    Institute of Scientific and Technical Information of China (English)

    LIU Xiao-yun; YU Jue-bang; LI Ming-yu

    2005-01-01

    In this paper, an object-oriented digital watermarking technique is proposed in the wavelet domain for still images. According to the difference of recognition degree of the human eye to the different region of the image, the image is divided into the interested region and uninterested region of human eye vision in this scheme. Using the relativity of position and the difference to ocular sensitivity of the multiresolution wavelet among each subband, the image is processed with layered watermarking append technique. Experimental results show that the proposed technique successfully survives image processing operations, additive noise and JPEG compression.

  11. ALL-Digital Baseband 65nm PLL/FPLL Clock Multiplier Using 10-Cell Library

    Science.gov (United States)

    Schuler, Robert L., Jr.; Wu, Qiong; Liu, Rui; Chen, Li; Madala, Shridhar

    2014-01-01

    PLLs for clock generation are essential for modern circuits, to generate specialized frequencies for many interfaces and high frequencies for chip internal operation. These circuits depend on analog circuits and careful tailoring for each new process, and making them fault tolerant is an incompletely solved problem. Until now, all digital PLLs have been restricted to sampled data DSP techniques and not available for the highest frequency baseband applications. This paper presents the design and preliminary evaluation of an all-digital baseband technique built entirely with an easily portable 10-cell digital library. The library is also described, as it aids in research and low volume design porting to new processes. The advantages of the digital approach are the wide variety of techniques available to give varying degrees of fault tolerance, and the simplicity of porting the design to new processes, even to exotic processes that may not have analog capability. The only tuning parameter is digital gate delay. An all-digital approach presents unique problems and standard analog loop stability design criteria cannot be directly used. Because of the quantization of frequency, there is effectively infinite gain for very small loop error feedback. The numerically controlled oscillator (NCO) based on a tapped delay line cannot be reliably updated while a pulse is active in the delay line, and ordinarily does not have enough frequency resolution for a low-jitter output.

  12. Developing Dynamic Digital Image Techniques with Continuous Parameters to Detect Structural Damage

    Directory of Open Access Journals (Sweden)

    Ming-Hsiang Shih

    2013-01-01

    Full Text Available Several earthquakes with strong magnitude occurred globally at various locations, especially the unforgettable tsunami disaster caused by the earthquake in Indonesia and Japan. If the characteristics of structures can be well understood to implement new technology, the damages caused by most natural disasters can be significantly alleviated. In this research, dynamic digital image correlation method for using continuous parameter is applied for developing a low-cost digital image correlation coefficient method with advanced digital cameras and high-speed computers. The experimental study using cantilever test object with defect control confirms that the vibration mode calculated using this proposed method can highly express the defect locations. This proposed method combined with the sensitivity of Inter-Story Drift Mode Shape, IDMS, can also reveal the damage degree of damage structure. These test and analysis results indicate that this proposed method is high enough for applying to achieve the object of real-time online monitoring of structure.

  13. Materialising digital collecting: An extended view of digital materiality

    OpenAIRE

    Mardon, Rebecca; Belk, Russell

    2018-01-01

    If digital objects are abundant and ubiquitous, why should consumers pay for, much less collect them? The qualities of digital code present numerous challenges for collecting, yet digital collecting can and does occur. We explore the role of companies in constructing digital consumption objects that encourage and support collecting behaviours, identifying material configuration techniques that materialise these objects as elusive and authentic. Such techniques, we argue, may facilitate those ...

  14. Ultra-wide-field imaging in diabetic retinopathy.

    Science.gov (United States)

    Ghasemi Falavarjani, Khalil; Tsui, Irena; Sadda, Srinivas R

    2017-10-01

    Since 1991, 7-field images captured with 30-50 degree cameras in the Early Treatment Diabetic Retinopathy Study were the gold standard for fundus imaging to study diabetic retinopathy. Ultra-wide-field images cover significantly more area (up to 82%) of the fundus and with ocular steering can in many cases image 100% of the fundus ("panretinal"). Recent advances in image analysis of ultra-wide-field imaging allow for precise measurements of the peripheral retinal lesions. There is a growing consensus in the literature that ultra-wide-field imaging improves detection of peripheral lesions in diabetic retinopathy and leads to more accurate classification of the disease. There is discordance among studies, however, on the correlation between peripheral diabetic lesions and diabetic macular edema and optimal management strategies to treat diabetic retinopathy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Finding Clusters of Galaxies in the Sloan Digital Sky Survey using Voronoi Tessellation

    International Nuclear Information System (INIS)

    Rita S.J., Kim

    2001-01-01

    The Sloan Digital Sky Survey has obtained 450 square degrees of photometric scan data, in five bands (u', g', r', i', z'), which the authors use to identify clusters of galaxies. They illustrate how they do star-galaxy separation, and present a simple and elegant method of detecting over-densities in the galaxy distribution, using the Voronoi Tessellation

  16. Digital Natives: Creating Emergent Exhibitions through Digital Technologies

    DEFF Research Database (Denmark)

    Smith, Rachel Charlotte; Iversen, Ole Sejer; Dindler, Christian

    2011-01-01

    . In this way, digital technology can contribute to the creation of emergent exhibitions in which the exhibition is created in dialogue between audiences and the museum. We present experiences from a current research project, the Digital Natives exhibition, in which digital technology was designed......Digital Technology can support the creation of dialogical spaces in the museum, both playful and reflective, that allow audiences to engage in the ongoing construction and reproduction of cultural heritage creating novel connections between self and others and between past, present and future...... as an integral part of the exhibition to encourage dialogue between audiences and the exhibition materials and thereby investigate how the exhibition emerge as a result of this dialogic co-construction inside the exhibition space. In short, the opportunities offered by digital technologies prompts us to consider...

  17. Enabling Digital Literacy

    DEFF Research Database (Denmark)

    Ryberg, Thomas; Georgsen, Marianne

    2010-01-01

    There are some tensions between high-level policy definitions of “digital literacy” and actual teaching practice. We need to find workable definitions of digital literacy; obtain a better understanding of what digital literacy might look like in practice; and identify pedagogical approaches, which...... support teachers in designing digital literacy learning. We suggest that frameworks such as Problem Based Learning (PBL) are approaches that enable digital literacy learning because they provide good settings for engaging with digital literacy. We illustrate this through analysis of a case. Furthermore......, these operate on a meso-level mediating between high-level concepts of digital literacy and classroom practice....

  18. Digital Preservation in Open-Source Digital Library Software

    Science.gov (United States)

    Madalli, Devika P.; Barve, Sunita; Amin, Saiful

    2012-01-01

    Digital archives and digital library projects are being initiated all over the world for materials of different formats and domains. To organize, store, and retrieve digital content, many libraries as well as archiving centers are using either proprietary or open-source software. While it is accepted that print media can survive for centuries with…

  19. Digital Density as the Driving Force of Digital Transformation Processes

    OpenAIRE

    Bush, Xavier

    2016-01-01

    Digital technologies have increased the influence of technology in business, even changing business models and strategies of organisations. This influence, called Digital Transformation of Business (DT), happens when there is an increase of the number of digital connections, information and interactions. This phenom-ena has been defined as Digital Density (DD) and aims to provide an assessment of the digitalization status of an organization. With the concept of DD we pro-pose the DD Framework, t...

  20. Reflux and Belching After 270 Degree Versus 360 Degree Laparoscopic Posterior Fundoplication

    NARCIS (Netherlands)

    Broeders, Joris A.; Bredenoord, Albert J.; Hazebroek, Eric J.; Broeders, Ivo A.; Gooszen, Hein G.; Smout, André J.

    2012-01-01

    Objective: To investigate differences in effects of 270 degrees (270 degrees LPF) and 360 degrees laparoscopic posterior fundoplication (360 degrees LPF) on reflux characteristics and belching. Background: Three hundred sixty degrees LPF greatly reduces the ability of the stomach to vent ingested