  1. Novel deflecting cavity design for eRHIC

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Q.; Belomestnykh, S.; Ben-Zvi, I.

    2011-07-25

    To prevent significant loss of the luminosity due to large crossing angle in the future ERL based Electron Ion Collider at BNL (eRHIC), there is a demand for crab cavities. In this article, we will present a novel design of the deflecting/crabbing 181 MHz superconducting RF cavity that will fulfil the requirements of eRHIC. The quarter-wave resonator structure of the new cavity possesses many advantages, such as compact size, high R{sub t}/Q, the absence of the same order mode and lower order mode, and easy higher order mode damping. We will present the properties and characteristics of the new cavity in detail. As the accelerator systems grow in complexity, developing compact and efficient deflecting cavities is of great interest. Such cavities will benefit situations where the beam line space is limited. The future linac-ring type electron-ion collider requires implementation of a crab-crossing scheme for both beams at the interaction region. The ion beam has a long bunches and high rigidity. Therefore, it requires a low frequency, large kicking angle deflector. The frequency of the deflecting mode for the current collider design is 181 MHz, and the deflecting angle is {approx}5 mrad for each beam. At such low frequency, the previous designs of the crab cavities will have very large dimensions, and also will be confronted by typical problems of damping the Lower Order Mode (LOM), the Same Order Mode (SOM), and as usual, the Higher Order Modes (HOM). In this paper we describe how one can use the concept of a quarter-wave (QW) resonator for a deflecting/crabbing cavity, and use its fundamental mode to deflect the beam. The simplicity of the cavity geometry and the large separation between its fundamental mode and the first HOM make it very attractive.

  2. Design and Development of Superconducting Parallel-Bar Deflecting/Crabbing Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Payagalage Subashini Uddi De Silva, Jean Delayen

    2012-07-01

    The superconducting parallel-bar cavity is a deflecting/crabbing cavity with attractive properties that is being considered for a number of applications. We present the designs of a 499 MHz deflecting cavity developed for the Jefferson Lab 12 GeV Upgrade and a 400 MHz crabbing cavity for the LHC High Luminosity Upgrade. Prototypes of these two cavities are now under development and fabrication.

  3. RF deflecting cavity design for Berkeley ultrafast X-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Li, Derun; Corlett, J.

    2002-05-30

    Our proposed source for production of ultra-short (less than 100 fs FWHM) x-ray pulses utilizes a scheme for manipulation of the relatively long ({approx}2 ps) electron bunch in transverse phase-space, followed by compression of the emitted x-ray pulse in crystal optics [1]. In order to compress the x-ray pulses, RF cavities operating in a dipole mode (TM{sub 110}-like) are required to deflect the head and tail of a 2.5 GeV bunch in opposite directions. For a 2 ps duration electron bunch, an 8.5 MV deflecting voltage is required at a RF frequency of 3.9 GHz. In this paper, we will present a preliminary cavity design based on numerical simulations performed by MAFIA and URMEL codes. Seven-cell superconducting {pi} mode dipole RF cavities are proposed to provide the necessary deflecting voltage. Due to the presence of beam iris, the cavities operate in a hybrid mode where TM and TE like modes co-exist. Even on the beam axis, both magnetic and electric fields contribute to the transverse kick. Lower order monopole modes (LOMs) in the cavities may cause energy spread of the electron beam and need to be damped. The effects of the LOMs on beam dynamics are estimated. Possible damping schemes will be discussed.

  4. RF deflecting cavity design for Berkeley ultrafast X-ray source

    Science.gov (United States)

    Li, D.; Corlett, J.

    2002-05-01

    Our proposed source for production of ultra-short (less than 100 fs FWHM) x-ray pulses utilizes a scheme for manipulation of the relatively long (2 ps) electron bunch in transverse phase-space, followed by compression of the emitted x-ray pulse in crystal optics. In order to compress the x-ray pulses, RF cavities operating in a dipole mode (TM110-like) are required to deflect the head and tail of a 2.5 GeV bunch in opposite directions. For a 2 ps duration electron bunch, an 8.5 MV deflecting voltage is required at a RF frequency of 3.9 GHz. In this paper, we will present a preliminary cavity design based on numerical simulations performed by MAFIA and URMEL codes. Seven-cell superconducting p mode dipole RF cavities are proposed to provide the necessary deflecting voltage. Due to the presence of beam iris, the mavities operate in a hybrid mode where TM and TE like modes co-exist. Even on mhe beam axis, both magnetic and electric fields contribute to the transverse mick. Lower order monopole modes (LOMs) in the cavities may cause energy spread of the electron beam and need to be damped. The effects of the LOMs on beam dynamics are estimated. Possible damping schemes will be discussed.

  5. Deflecting RF cavity design for a recirculating linac based facility for ultrafast X-ray science (LUX)

    Energy Technology Data Exchange (ETDEWEB)

    Li, Derun; Corlett, J.N.

    2003-05-01

    We report on superconducting deflecting RF cavity designs for a Recirculating Linac Based Facility for Ultrafast X-ray Science (LUX) at Lawrence Berkeley National Laboratory. The deflecting cavities operate in the lowest dipole mode and are required to produce a temporal correlation within flat electron bunches, as needed for x-ray compression in crystal optics. Deflecting voltage of up to 8.5-MV is required at 3.9-GHz. We present a 7-cell cavity design in this paper. Seven such cavities are required to generate the 8.5 MV deflecting voltage. Longitudinal and transverse impedance from LOM (lower order mode) and HOM (higher order mode) are simulated using the MAFIA code. Short-range and long-range wakefield excited through these impedances are calculated. Beam loading effects of the deflecting mode and LOM modes are estimated. Q values of the LOM monopole modes in the cavity may need to be damped to be below 10{sup 4}-10{sup 5} levels in order to maintain the required energy spread.

  6. SUPERCONDUCTING RF-DIPOLE DEFLECTING AND CRABBING CAVITIES

    Energy Technology Data Exchange (ETDEWEB)

    Delayen, Jean [ODU, JLAB; De Silva, Paygalage Subashini [ODU, JLAB

    2013-09-01

    Recent interests in designing compact deflecting and crabbing structures for future accelerators and colliders have initiated the development of novel rf structures. The superconducting rf-dipole cavity is one of the first compact designs with attractive properties such as higher gradients, higher shunt impedance, the absence of lower order modes and widely separated higher order modes. Two rf-dipole designs of 400 MHz and 499 MHz have been designed, fabricated and tested as proof-of-principle designs of compact deflecting and crabbing cavities for the LHC high luminosity upgrade and Jefferson Lab 12 GeV upgrade. The first rf tests have been performed on the rf-dipole geometries at 4.2 K and 2.0 K in a vertical test assembly with excellent results. The cavities have achieved high gradients with high intrinsic quality factors, and multipacting levels were easily processed.

  7. Coupler induced monopole component and its minimization in deflecting cavities

    Directory of Open Access Journals (Sweden)

    P. K. Ambattu

    2013-06-01

    Full Text Available Deflecting cavities are used in particle accelerators for the manipulation of charged particles by deflecting or crabbing (rotating them. For short deflectors, the effect of the power coupler on the deflecting field can become significant. The particular power coupler type can introduce multipole rf field components and coupler-specific wakefields. Coupler types that would normally be considered like standard on-cell coupler, waveguide coupler, or mode-launcher coupler could have one or two rf feeds. The major advantage of a dual-feed coupler is the absence of monopole and quadrupole rf field components in the deflecting structure. However, a dual-feed coupler is mechanically more complex than a typical single-feed coupler and needs a splitter. For most applications, deflecting structures are placed in regions where there is small space hence reducing the size of the structure is very desirable. This paper investigates the multipole field components of the deflecting mode in single-feed couplers and ways to overcome the effect of the monopole component on the beam. Significant advances in performance have been demonstrated. Additionally, a novel coupler design is introduced which has no monopole field component to the deflecting mode and is more compact than the conventional dual-feed coupler.

  8. Fabrication and Testing of Deflecting Cavities for APS

    Energy Technology Data Exchange (ETDEWEB)

    Mammosser, John; Wang, Haipeng; Rimmer, Robert; Jim, Henry; Katherine, Wilson; Dhakal, Pashupati; Ali, Nassiri; Jim, Kerby; Jeremiah, Holzbauer; Genfa, Wu; Joel, Fuerst; Yawei, Yang; Zenghai, Li

    2013-09-01

    Jefferson Lab (Newport News, Virginia) in collaboration with Argonne National Laboratory (Argonne, IL) has fabricated and tested four first article, 2.8 GHz, deflecting SRF cavities, for Argonne's Short-Pulse X-ray (SPX) project. These cavities are unique in many ways including the fabrication techniques in which the cavity cell and waveguides were fabricated. These cavity subcomponents were milled from bulk large grain niobium ingot material directly from 3D CAD files. No forming of sub components was used with the exception of the beam-pipes. The challenging cavity and helium vessel design and fabrication results from the stringent RF performance requirements required by the project and operation in the APS ring. Production challenges and fabrication techniques as well as testing results will be discussed in this paper.

  9. An improved equivalent circuit model of a four rod deflecting cavity

    Science.gov (United States)

    Apsimon, R.; Burt, G.

    2017-03-01

    In this paper we present an improved equivalent circuit model for a four rod deflecting cavity which calculates the frequencies of the first four modes of the cavity as well as the RT/Q for the deflecting mode. Equivalent circuit models of RF cavities give intuition and understanding about how the cavity operates and what changes can be made to modify the frequency, without the need for RF simulations, which can be time-consuming. We parameterise a generic four rod deflecting cavity into a geometry consisting of simple shapes. Equations are derived for the line impedance of the rods and the capacitance between the rods and these are used to calculate the resonant frequency of the deflecting dipole mode as well as the lower order mode and the model is bench-marked against two test cases; the CEBAF separator and the HL-LHC 4-rod LHC crab cavity. CST and the equivalent circuit model agree within 4% for both cavities with the LOM frequency and within 1% for the deflecting frequency. RT/Q differs between the model and CST by 37% for the CEBAF separator and 25% for the HL-LHC 4-rod crab cavity; however this is sufficient for understanding how to optimise the cavity design. The model has then been utilised to suggest a method of separating the modal frequencies in the HL-LHC crab cavity and to suggest design methodologies to optimise the cavity geometries.

  10. Cryogenic Test of a Proof-of-Principle Superconducting RF-Dipole Deflecting and Crabbing Cavity

    CERN Document Server

    De Silva, S U; Delayen, Jean Roger

    2013-01-01

    Recent applications in need of compact low-frequency deflecting and crabbing cavities have initiated the design and development of new superconducting structures operating at high gradients with low losses. Previously, TM$_{110}$ -type deflecting and crabbing cavities were developed and have also been operated successfully. However, these geometries are not favorable designs for low operating frequencies. The superconducting rf-dipole cavity is the first compact deflecting and crabbing geometry that has demonstrated high gradients and high shunt impedance. Since the fundamental operating mode is the lowest mode and is widely separated from the nearest higher order mode, the rf-dipole design is an attractive geometry for effective damping of the higher order modes in high current applications. A 400 MHz rf-dipole cavity was designed, fabricated, and tested as a proof-of-principle cavity. The cavity achieved high operating gradients, and the multipacting levels were easily processed and did not reoccur.

  11. Multipole Field Effects for the Superconducting Parallel-Bar Deflecting/Crabbing Cavities

    Energy Technology Data Exchange (ETDEWEB)

    De Silva, Payagalage Subashini Uddika [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States) and Old Dominion University, Norfolk, VA (United States); Delayen, Jean Roger [Old Dominion University, Norfolk, VA (United States)

    2012-09-01

    The superconducting parallel-bar deflecting/crabbing cavity is currently being considered as one of the design options in rf separation for the Jefferson Lab 12 GeV upgrade and for the crabbing cavity for the proposed LHC luminosity upgrade. Knowledge of multipole field effects is important for accurate beam dynamics study of rf structures. The multipole components can be accurately determined numerically using the electromagnetic surface field data in the rf structure. This paper discusses the detailed analysis of those components for the fundamental deflecting/crabbing mode and higher order modes in the parallel-bar deflecting/crabbing cavity.

  12. Analysis of HOM Properties of Superconducting Parallel-Bar Deflecting/Crabbing Cavities

    Energy Technology Data Exchange (ETDEWEB)

    S.U. De Silva, J.R. Delayen

    2011-07-01

    The superconducting parallel-bar cavity is currently being considered for a number of deflecting and crabbing applications due to improved properties and compact design geometries. The 499 MHz deflecting cavity proposed for the Jefferson Lab 12 GeV upgrade and the 400 MHz crab cavity for the proposed LHC luminosity upgrade are two of the major applications. For high current applications the higher order modes must be damped to acceptable levels to eliminate any beam instabilities. The frequencies and R/Q of the HOMs and mode separation are evaluated and compared for different parallel-bar cavity designs.

  13. Laser heating of a cavity versus a plane surface for metal targets utilizing photothermal deflection measurements

    Science.gov (United States)

    Jeong, S. H.; Greif, R.; Russo, R. E.

    1996-08-01

    The effects of a cylindrical cavity in a metal surface on the energy coupling of a laser beam with the solid were investigated by using a photothermal deflection technique. The photothermal deflection of a probe beam over the cavity was measured while the bottom of the cavity was heated with a Nd-YAG laser with a wavelength of 1064 nm. Cavities in three different materials and with two different aspect ratios were used for the experiment. Temperature distributions in the solid and the surrounding air were computed numerically and used to calculate photothermal deflections for cavity heating and for plane surface heating. Reflection of the heating laser beam inside the cavity increased the photothermal deflection amplitude significantly with larger increases for materials with larger thermal diffusivity. The computed photothermal deflections agreed more closely with the experimental results when reflection of the heating laser beam inside the cavity was included in the numerical model. The overall energy coupling between a heating laser and a solid is enhanced by a cavity.

  14. LIGHT SOURCE: RF deflecting cavity for bunch length measurement in Tsinghua Thomson scattering X-ray source

    Science.gov (United States)

    Shi, Jia-Ru; Chen, Huai-Bi; Tang, Chuan-Xiang; Huang, Wen-Hui; Du, Ying-Chao; Zheng, Shu-Xin; Ren, Li

    2009-06-01

    An RF deflecting cavity used for bunch length measurement has been designed and fabricated at Tsinghua University for the Thomson Scattering X-Ray Source. The cavity is a 2856 MHz, π-mode, 3-cell standing-wave cavity, to diagnose the 3.5 MeV beam produced by photocathode electron gun. With a larger power source, the same cavity will again be used to measure the accelerated beam with energy of 50 MeV before colliding with the laser pulse. The RF design using MAFIA for both the cavity shape and the power coupler is reviewed, followed by presenting the fabrication procedure and bench measurement results of two cavities.

  15. Deflection and focusing of charged particles by cavities of general shape

    Science.gov (United States)

    Hinderer, G.

    1991-04-01

    The integrated transverse momentum change of a charged particle in the rf field of a cavity can be related to the change of its voltage gain due to a virtual transverse displacement of its orbit. Formulas for the particle deflection are derived, which are a generalisation of the Panofsky-Wenzel theorem to an arbitrary cavity shape and to curved orbits through the cavity. In addition, some useful formulas for the transverse and longitudinal focusing are presented.

  16. High Power Test Of A 3.9 GHz 5-cell Deflecting-mode Cavity In A Cryogenic Operation

    CERN Document Server

    Shin, Young-Min

    2014-01-01

    A 3.9 GHz deflecting mode (pi, TM110) cavity has been long used for six-dimensional phase-space beam manipulation tests at the A0 Photo-Injector Lab (16 MeV) in Fermilab and their extended applications with vacuum cryomodules are currently planned at the Advanced Superconducting Test Accelerator (ASTA) user facility (> 50 MeV). Despite the successful test results, the cavity, however, demonstrated limited RF performance during liquid nitrogen (LN2) ambient operation that was inferior to theoretical prediction. We have been performing full analysis of the designed cavity by analytic calculation and comprehensive system simulation analysis to solve complex thermodynamics and mechanical stresses. The re-assembled cryomodule is currently under the test with a 50 kW klystron at the Fermilab A0 beamline, which will benchmark the modeling analysis. The test result will be used to design vacuum cryomodules for the 3.9 GHz deflecting mode cavity that will be employed at the ASTA facility for beam diagnostics and phase...

  17. HIGH POWER TEST OF A 3.9 GHZ 5-CELL DEFLECTING-MODE CAVITY IN A CRYOGENIC OPERATION

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Young-Min; Church, Michael

    2013-11-24

    A 3.9 GHz deflecting mode (S, TM110) cavity has been long used for six-dimensional phase-space beam manipulation tests [1-5] at the A0 Photo-Injector Lab (16 MeV) in Fermilab and their extended applications with vacuum cryomodules are currently planned at the Advanced Superconducting Test Accelerator (ASTA) user facility (> 50 MeV). Despite the successful test results, the cavity, however, demonstrated limited RF performance during liquid nitrogen (LN2) ambient operation that was inferior to theoretical prediction. We have been performing full analysis of the designed cavity by analytic calculation and comprehensive system simulation analysis to solve complex thermodynamics and mechanical stresses. The re-assembled cryomodule is currently under the test with a 50 kW klystron at the Fermilab A0 beamline, which will benchmark the modeling analysis. The test result will be used to design vacuum cryomodules for the 3.9 GHz deflecting mode cavity that will be employed at the ASTA facility for beam diagnostics and phase-space control.

  18. Deflecting cavity dynamics for time-resolved machine studies of SXFEL user facility

    CERN Document Server

    Song, Minghao; Liu, Bo; Wang, Dong

    2016-01-01

    Radio frequency deflectors are widely used for time-resolved electron beam energy, emittance and radiation profile measurements in modern free electron laser facilities. In this paper, we present the beam dynamics aspects of the deflecting cavity of SXFEL user facility, which is located at the exit of the undulator. With a targeted time resolution around 10 fs, it is expected to be an important tool for time-resolved commissioning and machine studies for SXFEL user facility.

  19. Slice emittance measurement for photocathode RF gun with solenoid scanning and RF deflecting cavity

    Science.gov (United States)

    Li, Chen; Huang, WenHui; Du, YingChao; Yan, LiXin; Tang, ChuanXiang

    2011-12-01

    The radiation of high-gain short-wavelength free-electron laser depends on the slice transverse emittance of the electron bunch. This essay introduces the method of slice emittance measurement, and shows the brief setup of this experiment using the solenoid scanning and RF deflecting cavity at Tsinghua University. The preliminary experimental results show that the slice rms emittance of the electron bunch generated by photocathode RF gun has considerable variations along the bunch and is typically less than 0.55 mm mrad for the laser rms radius of 0.4 mm.

  20. Slice emittance measurement for photocathode RF gun with solenoid scanning and RF deflecting cavity

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The radiation of high-gain short-wavelength free-electron laser depends on the slice transverse emittance of the electron bunch. This essay introduces the method of slice emittance measurement, and shows the brief setup of this experiment using the solenoid scanning and RF deflecting cavity at Tsinghua University. The preliminary experimental results show that the slice rms emittance of the electron bunch generated by photocathode RF gun has considerable variations along the bunch and is typically less than 0.55 mm mrad for the laser rms radius of 0.4 mm.

  1. Mission Design and Optimal Asteroid Deflection for Planetary Defense

    Science.gov (United States)

    Sarli, Bruno V.; Knittel, Jeremy M.; Englander, Jacob A.; Barbee, Brent W.

    2017-01-01

    Planetary defense is a topic of increasing interest for many reasons, which has been mentioned in "Vision and Voyages for Planetary Science in the Decade 2013-2022''. However, perhaps one of the most significant rationales for asteroid studies is the number of close approaches that have been documented recently. A space mission with a planetary defense objective aims to deflect the threatening body as far as possible from Earth. The design of a mission that optimally deflects an asteroid has different challenges: speed, precision, and system trade-off. This work addresses such issues and develops a fast transcription of the problem that can be implemented into an optimization tool, which allows for a broader trade study of different mission concepts with a medium fidelity. Such work is suitable for a mission?s preliminary study. It is shown, using the fictitious asteroid impact scenario 2017 PDC, that the complete tool is able to account for the orbit sensitivity to small perturbations and quickly optimize a deflection trajectory. The speed in which the tool operates allows for a trade study between the available hardware. As a result, key deflection dates and mission strategies are identified for the 2017 PDC.

  2. Mission Design and Optimal Asteroid Deflection for Planetary Defense

    Science.gov (United States)

    Sarli, Bruno V.; Knittel, Jeremy M.; Englander, Jacob A.; Barbee, Brent W.

    2017-01-01

    Planetary defense is a topic of increasing interest for many reasons, which has been mentioned in "Vision and Voyages for Planetary Science in the Decade 2013-2022". However, perhaps one of the most significant rationales for asteroid studies is the number of close approaches that have been documented recently. A space mission with a planetary defense objective aims to deflect the threatening body as far as possible from Earth. The design of a mission that optimally deflects an asteroid has different challenges: speed, precision, and system trade-off. This work addresses such issues and develops a fast transcription of the problem that can be implemented into an optimization tool, which allows for a broader trade study of different mission concepts with a medium fidelity. Such work is suitable for a mission's preliminary study. It is shown, using the fictitious asteroid impact scenario 2017 PDC, that the complete tool is able to account for the orbit sensitivity to small perturbations and quickly optimize a deflection trajectory. The speed in which the tool operates allows for a trade study between the available hardware. As a result, key deflection dates and mission strategies are identified for the 2017 PDC.

  3. JLEIC SRF cavity RF Design

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shaoheng [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Guo, Jiquan [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Wang, Haipeng [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Rimmer, Robert A. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-05-01

    The initial design of a low higher order modes (HOM) impedance superconducting RF (SRF) cavity is presented in this paper. The design of this SRF cavity is for the proposed Jefferson Lab Electron Ion Collider (JLEIC). The electron ring of JLEIC will operate with electrons of 3 to 10 GeV energy. The ion ring of JLEIC will operate with protons of up to 100 GeV energy. The bunch lengths in both rings are ~12 mm (RMS). In order to maintain the short bunch length in the ion ring, SRF cavities are adopted to provide large enough gradient. In the first phase of JLEIC, the PEP II RF cavities will be reused in the electron ring to lower the initial cost. The frequency of the SRF cavities is chosen to be the second harmonic of PEP II cavities, 952.6 MHz. In the second phase of JLEIC, the same frequency SRF cavities may replace the normal conducting PEP II cavities to achieve higher luminosity at high energy. At low energies, the synchro-tron radiation damping effect is quite weak, to avoid the coupled bunch instability caused by the intense closely-spaced electron bunches, low HOM impedance of the SRF cavities combined with longitudinal feedback sys-tem will be necessary.

  4. Design and Field Test of a Galvanometer Deflected Streak Camera

    Energy Technology Data Exchange (ETDEWEB)

    Lai, C C; Goosman, D R; Wade, J T; Avara, R

    2002-11-08

    We have developed a compact fieldable optically-deflected streak camera first reported in the 20th HSPP Congress. Using a triggerable galvanometer that scans the optical signal, the imaging and streaking function is an all-optical process without incurring any photon-electron-photon conversion or photoelectronic deflection. As such, the achievable imaging quality is limited mainly only by optical design, rather than by multiple conversions of signal carrier and high voltage electron-optics effect. All core elements of the camera are packaged into a 12 inch x 24 inch footprint box, a size similar to that of a conventional electronic streak camera. At LLNL's Site-300 Test Site, we have conducted a Fabry-Perot interferometer measurement of fast object velocity using this all-optical camera side-by-side with an intensified electronic streak camera. These two cameras are configured as two independent instruments for recording synchronously each branch of the 50/50 splits from one incoming signal. Given the same signal characteristics, the test result has undisputedly demonstrated superior imaging performance for the all-optical streak camera. It produces higher signal sensitivity, wider linear dynamic range, better spatial contrast, finer temporal resolution, and larger data capacity as compared with that of the electronic counterpart. The camera had also demonstrated its structural robustness and functional consistence to be well compatible with field environment. This paper presents the camera design and the test results in both pictorial records and post-process graphic summaries.

  5. Higher Order Mode Filter Design for Double Quarter Wave Crab Cavity for the LHC High Luminosity Upgrade

    CERN Document Server

    Xiao, B P; Ben-Zv, I; Burt, Graeme Campbell; Calaga, Rama; Capatina, Ofelia; Hall, B; Jones, T; Skaritka, J; Verdú-Andrés, S; Wu, Q

    2015-01-01

    A Double Quarter Wave Crab Cavity (DQWCC) was designed for the Large Hadron Collider (LHC) luminosity upgrade. A compact Higher Order Mode (HOM) filter with wide stop band at the deflecting mode is developed for this cavity. Multi-physics finite element simulation results are presented. The integration of this design to the cavity cryomodule is described.

  6. Higher order mode filter design for double quarter wave crab cavity for the LHC high luminosity upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Belomestnykh, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stony Brook Univ., NY (United States); Ben-Zvi, I. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stony Brook Univ., NY (United States); Burt, G. [Lancaster Univ. (United Kingdom); Calaga, R. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Capatina, O. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Hall, B. [Lancaster Univ. (United Kingdom); Jones, T. [Science and Technology Facilities Council (STFC), Daresbury (United Kingdom). Daresbury Lab.; Skaritka, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Verdu-Andres, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Wu, Q. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-05-03

    A Double Quarter Wave Crab Cavity (DQWCC) was designed for the Large Hadron Collider (LHC) luminosity upgrade. A compact Higher Order Mode (HOM) filter with wide stop band at the deflecting mode is developed for this cavity. Multiphysics finite element simulation results are presented. The integration of this design to the cavity cryomodule is described.

  7. Design Optimization of Deflection Caused After Release of Multilayer Structural Membrane of Symmetric Toggle Switch

    Directory of Open Access Journals (Sweden)

    K. Maninder

    2011-01-01

    Full Text Available This paper presents the optimization in deflection caused by the inbuilt stress generated in mechanical or movable membrane of Symmetric Toggle RF MEMS Switch (STS. The movable membrane of STS was initially fabricated with two different materials, i.e. Chrome and Gold. The simulated deflection at 70 °C was 11.9 µm, and experimental deflection was 11-12 µm. We present a study of inbuilt deflection reduction in multimetal movable layers without change in actuation voltage of the switch. The design study was initially carried out on cantilevers and then on structural membrane of STS. STS with proposed multilayer of Cr-Au-Au-Ti-Au has a simulated deflection of 0.56 µm at 70 °C.

  8. Design of Electron and Ion Crabbing Cavities for an Electron-Ion Collider

    Energy Technology Data Exchange (ETDEWEB)

    Alejandro Castilla Loeza, Geoffrey Krafft, Jean Delayen

    2012-07-01

    Beyond the 12 GeV upgrade at the Jefferson Lab a Medium Energy Electron-Ion Collider (MEIC) has been considered. In order to achieve the desired high luminosities at the Interaction Points (IP), the use of crabbing cavities is under study. In this work, we will present to-date designs of superconducting cavities, considered for crabbing both ion and electron bunches. A discussion of properties such as peak surface fields and higher-order mode separation will be presented. Keywords: super conducting, deflecting cavity, crab cavity.

  9. Study of Gain in C-Band Deflection Cavities for a Frequency-Doubling Magnicon Amplifier

    Science.gov (United States)

    1993-03-26

    surface cleanliness , and background vacuum pressure. The threshold for multipactor in the drive cavity, in the presence of the axial magnetic field, was...different degrees of surface cleanliness . In order to make an unambiguous test of the linear interaction theory, the experimental gain measurements were

  10. Design, prototyping and testing of a compact superconducting double quarter wave crab cavity

    CERN Document Server

    Xiao, Binping; Belomestnykh, Sergey; Ben-Zvi, Ilan; Calaga, Rama; Cullen, Chris; Capatina, Ofelia; Hammons, Lee; Li, Zenghai; Marques, Carlos; Skaritka, John; Verdú-Andres, Silvia; Wu, Qiong

    2015-01-01

    A novel design of superconducting Crab Cavity was proposed and designed at Brookhaven National Laboratory. The new cavity shape is a Double Quarter Wave or DQWCC. After fabrication and surface treatments, the niobium proof-of-principle cavity was cryogenically tested in a vertical cryostat. The cavity is extremely compact yet has a low frequency of 400 MHz, an essential property for service for the Large Hadron Collider luminosity upgrade. The electromagnetic properties of the cavity are also well matched for this demanding task. The demonstrated deflecting voltage of 4.6 MV is well above the requirement for a crab cavity in the future High Luminosity LHC of 3.34 MV. In this paper we present the design, prototyping and test results of the DQWCC.

  11. Time-of-flight electron energy loss spectroscopy using TM110 deflection cavities

    Directory of Open Access Journals (Sweden)

    W. Verhoeven

    2016-09-01

    Full Text Available We demonstrate the use of two TM110 resonant cavities to generate ultrashort electron pulses and subsequently measure electron energy losses in a time-of-flight type of setup. The method utilizes two synchronized microwave cavities separated by a drift space of 1.45 m. The setup has an energy resolution of 12 ± 2 eV FWHM at 30 keV, with an upper limit for the temporal resolution of 2.7 ± 0.4 ps. Both the time and energy resolution are currently limited by the brightness of the tungsten filament electron gun used. Through simulations, it is shown that an energy resolution of 0.95 eV and a temporal resolution of 110 fs can be achieved using an electron gun with a higher brightness. With this, a new method is provided for time-resolved electron spectroscopy without the need for elaborate laser setups or expensive magnetic spectrometers.

  12. Time-of-flight electron energy loss spectroscopy using TM110 deflection cavities.

    Science.gov (United States)

    Verhoeven, W; van Rens, J F M; van Ninhuijs, M A W; Toonen, W F; Kieft, E R; Mutsaers, P H A; Luiten, O J

    2016-09-01

    We demonstrate the use of two TM110 resonant cavities to generate ultrashort electron pulses and subsequently measure electron energy losses in a time-of-flight type of setup. The method utilizes two synchronized microwave cavities separated by a drift space of 1.45 m. The setup has an energy resolution of 12 ± 2 eV FWHM at 30 keV, with an upper limit for the temporal resolution of 2.7 ± 0.4 ps. Both the time and energy resolution are currently limited by the brightness of the tungsten filament electron gun used. Through simulations, it is shown that an energy resolution of 0.95 eV and a temporal resolution of 110 fs can be achieved using an electron gun with a higher brightness. With this, a new method is provided for time-resolved electron spectroscopy without the need for elaborate laser setups or expensive magnetic spectrometers.

  13. Time-of-flight electron energy loss spectroscopy using TM110 deflection cavities

    Science.gov (United States)

    Verhoeven, W.; van Rens, J. F. M.; van Ninhuijs, M. A. W.; Toonen, W. F.; Kieft, E. R.; Mutsaers, P. H. A.; Luiten, O. J.

    2016-01-01

    We demonstrate the use of two TM110 resonant cavities to generate ultrashort electron pulses and subsequently measure electron energy losses in a time-of-flight type of setup. The method utilizes two synchronized microwave cavities separated by a drift space of 1.45 m. The setup has an energy resolution of 12 ± 2 eV FWHM at 30 keV, with an upper limit for the temporal resolution of 2.7 ± 0.4 ps. Both the time and energy resolution are currently limited by the brightness of the tungsten filament electron gun used. Through simulations, it is shown that an energy resolution of 0.95 eV and a temporal resolution of 110 fs can be achieved using an electron gun with a higher brightness. With this, a new method is provided for time-resolved electron spectroscopy without the need for elaborate laser setups or expensive magnetic spectrometers. PMID:27704035

  14. Design of the ILC Crab Cavity System

    Energy Technology Data Exchange (ETDEWEB)

    Adolphsen, C.; Beard, C.; Bellantoni, L.; Burt, G.; Carter, R.; Chase, B.; Church, M.; Dexter, A.; Dykes, M.; Edwards, H.; Goudket, P; Jenkins, R.; Jones, R.M.; Kalinin,; Khabiboulline, T.; Ko, K.; Latina, A.; Li, Z.; Ma, L.; McIntosh, P.; Ng, C.; /SLAC /Daresbury /Fermilab /Cockcroft Inst. Accel. Sci. Tech. /CERN

    2007-08-15

    The International Linear Collider (ILC) has a 14 mrad crossing angle in order to aid extraction of spent bunches. As a result of the bunch shape at the interaction point, this crossing angle at the collision causes a large luminosity loss which can be recovered by rotating the bunches prior to collision using a crab cavity. The ILC baseline crab cavity is a 9-cell superconducting dipole cavity operating at a frequency of 3.9 GHz. In this paper the design of the ILC crab cavity and its phase control system, as selected for the RDR in February 2007 is described in fuller detail.

  15. Proven procedures guide cavity VCO design

    Science.gov (United States)

    Lefrak, F.

    1981-05-01

    The design of a high performance voltage-tuned cavity oscillator is discussed. The circuit is to be modeled with an equivalent inductance and capacitance. Close attention is to be given to the influence of cavity loading. Center frequency and impedance are computed on the basis of the model's L and C values. The last step is particularly important, since the size of a cavity-based oscillator, such as the Gunn/varactor version is directly related to operating frequency. Attention is given to the parallel L-C circuit representing the cavity, parameter relations concerning the height, higher-order TE modes, and effects of post inductance. The basic oscillator consists of a hollow cavity with metal walls, and diodes mounted on posts.

  16. Rationale for designing cavity preparations.

    Science.gov (United States)

    Laswell, H R; Welk, D A

    1985-04-01

    Increased resistance to caries, increased dental awareness, superior diagnostic capabilities, better illumination, optical aids that significantly enhance vision, improved and standardized materials for restoration, and a deeper understanding of the caries process enable a far more conservative approach to tooth preparation. The dentist can concentrate on preserving as much sound tooth structure as possible with less attention being devoted to resistance and retention form that previously demanded in bulk restorations and massive channels and locks that are no longer appropriate. Although caries inhibitory effects have been shown with materials such as silicate cement, glass ionomers, and resins that leach fluoride, in general, dentists should not rely on restorative materials to inhibit the development of future decay. Characteristics of the carious lesion are unique for each tooth according to many factors centering around the plaque pattern for that tooth and not according to zones of natural susceptibility or immunity strictly dictated by morphology. Therefore, no single cavity preparation duplicated from a textbook is likely to be satisfactory for an individual tooth. Furthermore, novices learning the subject of cavity preparation often leave decalcified enamel when they attempt to replicate under clinical conditions that which they have learned in technique courses. This is the major invitation to future caries reappearing adjacent to restorations. Also, failure to duplicate the exact morphology of the tooth surface that has been replaced is likely to alter the pattern of plaque accumulation and create other caries prone areas.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Crab Cavity Development

    CERN Document Server

    Calaga, R; Burt, G; Ratti, A

    2015-01-01

    The HL-LHC upgrade will use deflecting (or crab) cavities to compensate for geometric luminosity loss at low β* and non-zero crossing angle. A local scheme with crab cavity pairs across the IPs is used employing compact crab cavities at 400 MHz. Design of the cavities, the cryomodules and the RF system is well advanced. The LHC crab cavities will be validated initially with proton beam in the SPS.

  18. Multiple harmonic frequencies resonant cavity design and half-scale prototype measurements for a fast kicker

    Science.gov (United States)

    Huang, Yulu; Wang, Haipeng; Rimmer, Robert A.; Wang, Shaoheng; Guo, Jiquan

    2016-12-01

    Quarter wavelength resonator (QWR) based deflecting cavities with the capability of supporting multiple odd-harmonic modes have been developed for an ultrafast periodic kicker system in the proposed Jefferson Lab Electron Ion Collider (JLEIC, formerly MEIC). Previous work on the kicking pulse synthesis and the transverse beam dynamics tracking simulations show that a flat-top kicking pulse can be generated with minimal emittance growth during injection and circulation of the cooling electron bunches. This flat-top kicking pulse can be obtained when a DC component and 10 harmonic modes with appropriate amplitude and phase are combined together. To support 10 such harmonic modes, four QWR cavities are used with 5, 3, 1, and 1 modes, respectively. In the multiple-mode cavities, several slightly tapered segments of the inner conductor are introduced to tune the higher order deflecting modes to be harmonic, and stub tuners are used to fine tune each frequency to compensate for potential errors. In this paper, we summarize the electromagnetic design of the five-mode cavity, including the geometry optimization to get high transverse shunt impedance, the frequency tuning and sensitivity analysis, and the single loop coupler design for coupling to all of the harmonic modes. In particular we report on the design and fabrication of a half-scale copper prototype of this proof-of-principle five-odd-mode cavity, as well as the rf bench measurements. Finally, we demonstrate mode superposition in this cavity experimentally, which illustrates the kicking pulse generation concept.

  19. Design of 162 MHz RF Experimental Cavity

    Institute of Scientific and Technical Information of China (English)

    YIN; Zhi-guo; CAO; Xue-long; GUO; Juan-juan; JI; Bin; FU; Xiao-liang; WEI; Jun-yi

    2015-01-01

    In this paper,a 162MHz RF experimental cavity is designed to study the multipacting multiplier effect of the medium and the metal electrode and its relationship with the plate surface characteristics,and to find out the method for inhibiting multipacting multiplier effects.The

  20. Injector Cavities Fabrication, Vertical Test Performance and Primary Cryomodule Design

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Haipeng [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Cheng, Guangfeng [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Clemens, William [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Davis, G [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Macha, Kurt [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Overton, Roland [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Spell, D. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2015-09-01

    After the electromagnetic design and the mechanical design of a β=0.6, 2-cell elliptical SRF cavity, the cavity has been fabricated. Then both 2-cell and 7-cell cavities have been bench tuned to the target values of frequency, coupling external Q and field flatness. After buffer chemistry polishing (BCP) and high pressure rinses (HPR), Vertical 2K cavity test results have been satisfied the specifications and ready for the string assembly. We will report the cavity performance including Lorenz Force Detuning (LFD) and Higher Order Modes (HOM) damping data. Its integration with cavity tuners to the cryomodule design will be reported.

  1. Design and Prototyping of a 400 MHz RF-dipole Crabbing Cavity for the LHC High-Luminosity Upgrade

    CERN Document Server

    De Silva, S U; Delayen, J R; Li, Z; Nicol, T H

    2015-01-01

    LHC High Luminosity Upgrade is in need of two crabbing systems that deflects the beam in both horizontal and vertical planes. The 400 MHz rf-dipole crabbing cavity system is capable of crabbing the proton beam in both planes. At present we are focusing our efforts on a complete crabbing system in the horizontal plane. Prior to LHC installation the crabbing system will be installed for beam test at SPS. The crabbing system consists of two rfdipole cavities in the cryomodule. This paper discusses the electromagnetic design and mechanical properties of the rf-dipole crabbing system for SPS beam test.

  2. Design of S-band re-entrant cavity BPM

    Institute of Scientific and Technical Information of China (English)

    LUO Qing; SUN Baogen; HE Duohui

    2009-01-01

    An S-band cavity BPM is designed for a new injector for HLS (Hefei Light Source). It consists of two cavities that work on 2448 MHz: a re-entrant position cavity tuned to TM110 mode and a reference cavity tuned to TM010 mode. Cut-through waveguides are used as pickups to suppress the monopole signal. Simulations with different assumption of dimension change are performed to evaluate errors caused by mechanical error and give general tolerance. Design of electronics is given. Theoretical resolution of this design is 31 nm.

  3. Multipacting Analysis of the Superconducting Parallel-bar Cavity

    Energy Technology Data Exchange (ETDEWEB)

    S.U. De Silva, J.R. Delayen,

    2011-03-01

    The superconducting parallel-bar cavity is a deflecting/crabbing cavity with attractive properties, compared to other conventional designs, that is being considered for a number of applications. Multipacting can be a limiting factor to the performance of in any superconducting structure. In the parallel-bar cavity the main contribution to the deflection is due to the transverse deflecting voltage, between the parallel bars, making the design potentially prone to multipacting. This paper presents the results of analytical calculations and numerical simulations of multipacting in the parallel-bar cavity with resonant voltage, impact energies and corresponding particle trajectories.

  4. Cavity design for high-frequency axion dark matter detectors.

    Science.gov (United States)

    Stern, I; Chisholm, A A; Hoskins, J; Sikivie, P; Sullivan, N S; Tanner, D B; Carosi, G; van Bibber, K

    2015-12-01

    In an effort to extend the usefulness of microwave cavity detectors to higher axion masses, above ∼8 μeV (∼2 GHz), a numerical trade study of cavities was conducted to investigate the merit of using variable periodic post arrays and regulating vane designs for higher-frequency searches. The results show that both designs could be used to develop resonant cavities for high-mass axion searches. Multiple configurations of both methods obtained the scanning sensitivity equivalent to approximately 4 coherently coupled cavities with a single tuning rod.

  5. Cavity design for high-frequency axion dark matter detectors

    CERN Document Server

    Stern, I; Hoskins, J; Sikivie, P; Sullivan, N S; Tanner, D B; Carosi, G; van Bibber, K

    2016-01-01

    In an effort to extend the usefulness of microwave cavity detectors to higher axion masses, above ~8 $\\mu$eV (~2 GHz), a numerical trade study of cavities was conducted to investigate the merit of using variable periodic post arrays and regulating vane designs for higher-frequency searches. The results show that both designs could be used to develop resonant cavities for high-mass axion searches. Multiple configurations of both methods obtained the scanning sensitivity equivalent to approximately 4 coherently coupled cavities with a single tuning rod.

  6. Fundamental Research in Superconducting RF Cavity Design

    Energy Technology Data Exchange (ETDEWEB)

    Georg Hoffstaetter

    2012-11-13

    This is a 3-year SRF R&D proposal with two main goals: 1) to benefit near term high gradient SRF applications by understanding the causes of quench at high fields in present-day niobium cavities 2) to open the long-range prospects for SRF applications by experimentally verifying the recent exciting theoretical predication for new cavity materials such as Nb3Sn and MgB2. These predictions shwo that ultimately gradients of 100Mv/m to 200MV/m may become possible as material imperfections are overcome.

  7. Design and Optimization of Thermophotovoltaic System Cavity with Mirrors

    Directory of Open Access Journals (Sweden)

    Tian Zhou

    2016-09-01

    Full Text Available Thermophotovoltaic (TPV systems can convert radiant energy into electrical power. Here we explore the design of the TPV system cavity, which houses the emitter and the photovoltaic (PV cells. Mirrors are utilized in the cavity to modify the spatial and spectral distribution within. After discussing the basic concentric tubular design, two novel cavity configurations are put forward and parametrically studied. The investigated variables include the shape, number, and placement of the mirrors. The optimization objectives are the optimized efficiency and the extended range of application of the TPV system. Through numerical simulations, the relationship between the design parameters and the objectives are revealed. The results show that careful design of the cavity configuration can markedly enhance the performance of the TPV system.

  8. Design of the Advanced Virgo non-degenerate recycling cavities

    Energy Technology Data Exchange (ETDEWEB)

    Granata, M; Barsuglia, M [Laboratoire Astroparticule et Cosmologie (APC) 10 rue Alice Domon et Leonie Duquet, 75013 Paris (France); Flaminio, R [Laboratoire des Materiaux Avances (LMA), IN2P3/CNRS F-69622 Villeurbanne, Lyon (France); Freise, A [School of Physics and Astronomy, University of Birmingham Birmingham, B15 2TT (United Kingdom); Hild, S [Institute for Gravitational Research, Department of Physics and Astronomy University of Glasgow, Glasgow, G12 8QQ (United Kingdom); Marque, J, E-mail: granata@apc.univ-paris7.f [European Gravitational Observatory (EGO) I-56021 Cascina (Italy)

    2010-05-01

    Advanced Virgo is the project to upgrade the interferometric gravitational wave detector Virgo, and it foresees the implementation of power and signal non-degenerate recycling cavities. Such cavities suppress the build-up of high order modes of the resonating sidebands, with some advantage for the commissioning of the detector and the build-up of the gravitational signal. Here we present the baseline design of the Advanced Virgo non-degenerate recycling cavities, giving some preliminary results of simulations about the tolerances of this design to astigmatism, mirror figure errors and thermal lensing.

  9. Simulation and Prototype Design of Variable Step Angle Techniques Based Asteroid Deflection for Future Planetary Mission

    Science.gov (United States)

    Sathiyavel, C.

    2016-07-01

    Asteroids are minor planets, especially those of the inner Solar System. The most desirable asteroids for cross the geo-synchronous orbit are the carbonaceous C-type asteroids that are deemed by the astronomy community to have a planetary protection categorization of unrestricted Earth return. The mass of near earth Asteroids (assuming spherical asteroid) as a function of its diameter varies from 2 m to 10m, the corresponding densities from 1.9/cm3 to 3.8 g/cm3. For example, a 6.5-m diameter asteroid with a density of 2.8 g/cm3 has a mass of order 4,00,000 kg. If this Asteroid falls on earth then the earth will be destroyed at when the equally of inclination angle both of earth and Asteroid. My proposed work is how we can avert this great danger for near feature the above mass of Asteroid. The present work is Simulation and Prototype Design of a Variable Step Angle Techniques Based Asteroid Deflection for future planetary Mission. Proposed method is comparing with previous method that will be very useful to achieving hit the ion velocity to asteroid surface in several direction at static position of Asteroid deviate mission[ADM].The deviate angle α1 to α2 with help of Variable step angle techniques, it is containing Stepper Motor with attach of Ion propulsion module system.VASAT module is locating the top edge on the three axis stabilized Method in ADM.The three axis stabilized method is including the devices are like Gyroscope sensor ,Arduino Microcontroller system and ion propulsion techniques. Arduino Microcontroller system determines the orientation from gyroscope sensor. Then it uses ion Propulsion techniques modules to control the required motion like pitch, yaw and roll attitude of the ADM. The exhaust thrust value is 1500 mN and velocity is 10,000 m/s [from simulation results but experimental output results is small because low quality of Components is used in research lab] .The propulsion techniques also used as a static position of ADM Mission [both

  10. FPC and Hi-Pass Filter HOM Coupler Design for the RF Dipole Crab Cavity for the LHC HiLumi Upgrade

    CERN Document Server

    Li, Z; Delayen, Jean Roger; De Silva, S U; Park, HyeKyoung; Olave, R G

    2015-01-01

    A 400-MHz compact RF dipole (RFD) crab cavity design was jointly developed by Old Dominion University and SLAC under the support of US LARP program for the LHC HiLumi upgrade. The RFD cavity design is consisted of a rounded-square tank and two ridged deflecting poles, operating with a TE11-like dipole mode, which is the lowest mode of the cavity. A prototype RFD cavity is being manufactured and will be tested on the SPS beam line at CERN. The coaxial fundamental Power Coupler (FPC) of the prototype cavity was re-optimized to minimizing the power heating on the coupler internal antenna. A hi-pass filter HOM damping coupler was developed to achieve the required wakefield damping while maintaining a compact size to fit into the beam line space. In this paper, we will discuss the details of the RF optimization and tolerance analyses of the FPC and HOM couplers.

  11. Design Criteria for Deflection Capacity of Conventionally Reinforced Concrete Slabs. Phase II. Design and Construction Requirements.

    Science.gov (United States)

    1980-10-01

    A T DERECHO , M IGRAL N68305-79-C00 UNCLASSIFIED CEL-CR-.A07 NL .... DTIC tC’ 80-EV27 T-4 CIVIL ENGINEERING LABORATORY Naval Construction Battalion...Design and Construction Requirements by T. Takayanagi, A.T. Derecho , and M. Iqbal* 1. INTRODUCTION 1.1 Objective and Scope The primary objective of this...bars, lightweight concrete, etc., are not clearly de- fined . In addition, inconsistencies in the values of fh ob- tained by using ACI 318-77 have

  12. Design and studies on the traveling wave transverse RF deflecting structure

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jing-Ru; HOU Mi; DAI Jian-Ping; PEI Shi-Lun; PEI Guo-Xi

    2008-01-01

    With the development of free electron laser (FEL) and the international linear collider (ILC), the electron bunch length is getting smaller and smaller. The traveling-wave transverse RF deflecting structure is an important part of the RF deflecting method for bunch length measurement and phase space diagnostics.The operation mode in RF deflector is the "TM11-like" mode. Since the TM11-like mode in this structure has a pair of degenerate dipole modes, two additional holes are provided on either side of each iris to stabilize the mode. The simulation and optimization have been done. A prototype has been fabricated and tested. The cold test results have been compared with the simulations of the first three modes.

  13. A design for an 802 MHz ERL Cavity

    CERN Document Server

    Calaga, Rama

    2015-01-01

    A low to medium energy recovery linac facility from 150-450-900 MeV in several stages is under study at CERN for validating important beam dynamics aspects and superconducting RF technology. A five-cell cavity design at 802MHz is proposed as a basic structure of the accelerating module. Aspects related to the cavity shape optimization of are described along some comments on the RF power.

  14. Design of photonic crystal microcavities for cavity QED.

    Science.gov (United States)

    Vucković, Jelena; Loncar, Marko; Mabuchi, Hideo; Scherer, Axel

    2002-01-01

    We discuss the optimization of optical microcavity designs based on two-dimensional photonic crystals for the purpose of strong coupling between the cavity field and a single neutral atom trapped within a hole. We present numerical predictions for the quality factors and mode volumes of localized defect modes as a function of geometric parameters, and discuss some experimental challenges related to the coupling of a defect cavity to gas-phase atoms.

  15. RF cavity design for KIRAMS-430 superconducting cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Jung, In Su, E-mail: jis@kirams.re.kr [Korea Institute of Radiological & Medical Sciences (KIRMAS), 75 Nowon-Gil, Nowon-Gu, Seoul 139-706 (Korea, Republic of); Hong, Bong Hwan; Kang, Joonsun; Kim, Hyun Wook; Kim, Chang Hyeuk [Korea Institute of Radiological & Medical Sciences (KIRMAS), 75 Nowon-Gil, Nowon-Gu, Seoul 139-706 (Korea, Republic of); Kwon, Key Ho [School of Information and Communication Engineering, Natural Sciences Campus, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of)

    2015-03-21

    The Korea Heavy Ion Medical Accelerator (KHIMA) has developed a superconducting cyclotron for the carbon therapy, which is called KIRAMS-430. The cyclotron is designed to accelerate only {sup 12}C{sup 6+} ions up to the energy of 430 MeV/u. It uses two normal conducting RF cavities. The RF frequency is about 70.76 MHz. The nominal dee voltage is 70 kV at the center and 160 kV at the extraction. The RF cavity was designed with 4 stems by using CST microwave studio (MWS). In this paper, we represent the simulation results and the optimized design of the RF cavity for the KIRAMS-430.

  16. Design and optimization of microbolometer multilayer optical cavity

    Energy Technology Data Exchange (ETDEWEB)

    Awad, E.; Al-Khalli, N.; Debbar, N. [Electrical Engineering Department, College of Engineering, King Saud University, Riyadh 11421 (Saudi Arabia); Abdel-Rahman, M., E-mail: mabdelrahman@ksu.edu.sa [Prince Sultan Advanced Technologies Research Institute (PSATRI), College of Engineering, King Saud University, Riyadh 11421 (Saudi Arabia); Alduraibi, M. [Physics and Astronomy Department, College of Science, King Saud University, Riyadh 11451 (Saudi Arabia); National Center for Applied Physics, King Abdulaziz City for Science and Technology, KACST, P.O. Box 6086, Riyadh 11442 (Saudi Arabia)

    2015-03-30

    Microbolometers are the most widely used detectors in long-wave infrared uncooled thermal imagers. An optical cavity is required within a microbolometer structure to increase its optical absorption. In this work we present a detailed study on the design and optimization of a microbolometer optical cavity using Essential-Macleod package. In the simulations, the cavity is considered as thin film multi-layers that form cascaded Fabry-Perot optical cavities. In the design phase, the layers structures are selected including materials and initial thickness. The absorbing layers are chosen to be vanadium-pentoxide (V{sub 2}O{sub 5}) and titanium (Ti). In the optimization phase, the designed layer thicknesses are varied to maximize optical absorption within the absorbing layers. The simulations show that Ti layer absorption dominates over V{sub 2}O{sub 5} layer. Also, the optimization proves that the air-gap cavity thickness is not simply quarter-wavelength because of the complex cascaded Fabry-Perot structure. The optimized air-gap thickness here is ≈3.5 µm at 10.6µm wavelength.

  17. Ultra-high-Q nanobeam cavity design in Diamond

    CERN Document Server

    Bayn, Igal; Kalish, Rafi

    2010-01-01

    A novel nanobeam design with a triangular cross-section is proposed. This design makes possible implementing nanocavities with improved optical properties. The dependence of a diamond-based cavity quality factor Q and mode volume Vm on geometry parameter space are studied via 3D FDTD computations. An ultra-high-Q cavity with Q\\aprox 2.51 \\times 10^6 and Vm=1.06 \\times ({\\lambda}/n)^3 is predicted. The mode preferential radiation is upward. The implications on the potential applications are discussed. The proposed nanobeam enables fabrication of the cavity without relying on a pre-existing free-standing diamond membrane as required in most previous approaches.

  18. Mechanical Design and Fabrication Studies for SPL Superconducting RF Cavities

    CERN Document Server

    Atieh, S; Aviles Santillana, I; Capatina, O; Renaglia, T; Tardy, T; Valverde Alonso, N; Weingarten, W

    2011-01-01

    CERN’s R&D programme on the Superconducting Proton Linac’s (SPL) superconducting radio frequency (SRF) elliptical cavities made from niobium sheets explores new mechanical design and consequently new fabrication methods, where several opportunities for improved optimization were identified. A stainless steel helium vessel is under design rather than a titanium helium vessel using an integrated brazed transition between Nb and the SS helium vessel. Different design and fabrication aspects were proposed and the results are discussed hereafter.

  19. Cavities

    Science.gov (United States)

    ... may pass these bacteria to a child through kissing, sampling the child's food, or sharing eating utensils. ... pass decay-causing bacteria to their children through kissing or sharing eating utensils. Symptoms of Cavities Whether ...

  20. Photoinjector RF cavity design for high power CW FEL

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S. (Sergey); Schrage, D. L. (Dale L.); Wood R. L. (Richard L.); Young, L. M. (Lloyd M.); Schultheiss, T. (Thomas); Christina, V.; Rathke, J.

    2003-01-01

    The project is under way to develop a key enabling technology for highpower CW FEL: an RF photoinjector capable of producing continuous average current greater than 100 mA. The specific aim is a n-mode, normalconducting IW photoinjector, 3 nC of bunch charge, 100 mA of current (at 33.3-MHz bunch repetition rate) and emittance less than 10 mm-mad. This level of performance will enable robust 100-kW-class FEL operation with electron beam energy <100 MeV, thereby reducing the size and cost of the FEL. This design is scalable to the MW power level by increasing the electron bunch repetition rate to a higher value. The major challenges are emittance control and high heat flux within the CW 700-MHz RF cavities. Results of RF cavity design and cooling schemes are presented, including both high-velocity water and liquid-nitrogen cooling options.

  1. Design Topics for Superconducting RF Cavities and Ancillaries

    CERN Document Server

    Padamsee, H

    2014-01-01

    RF superconductivity has become a major subfield of accelerator science. There has been an explosion in the number of accelerator applications and in the number of laboratories engaged. The first lecture at this meeting of the CAS presented a review of fundamental design principles to develop cavity geometries to accelerate velocity-of-light particles (β = v/c ~ 1), moving on to the corresponding design principles for medium-velocity (medium-β) and low-velocity (low-β) structures. The lecture included mechanical design topics. The second lecture dealt with input couplers, higher-order mode extraction couplers with absorbers, and tuners of both the slow and fast varieties.

  2. BERLinPro Booster Cavity Design, Fabrication and Test Plans

    Energy Technology Data Exchange (ETDEWEB)

    Burrill, Andrew [HZB; Anders, W [HZB; Frahm, A. [HZB; Knobloch, Jens [HZB; Neumann, Axel [HZB; Ciovati, Gianluigi [JLAB; Kneisel, Peter K. [JLAB; Turlington, Larry D. [JLAB

    2014-12-01

    The bERLinPro project, a 100 mA, 50 MeV superconducting RF (SRF) Energy Recovery Linac (ERL) is under construction at Helmholtz-Zentrum Berlin for the purpose of studying the technical challenges and physics of operating a high current, c.w., 1.3 GHz ERL. This machine will utilize three unique SRF cryomodules for the injector, booster and linac module respectively. The booster cryomodule will contain three 2-cell SRF cavities, based on the original design by Cornell University, and will be equipped with twin 115 kW RF power couplers in order to provide the appropriate acceleration to the high current electron beam. This paper will review the status of the fabrication of the 4 booster cavities that have been built for this project by Jefferson Laboratory and look at the challenges presented by the incorporation of fundamental power couplers capable of delivering 115 kW. The test plan for the cavities and couplers will be given along with a brief overview of the cryomodule design.

  3. Chirped-cavity dispersion-compensation filter design

    Science.gov (United States)

    Li, Ya-Ping; Chen, Sheng-Hui; Lee, Cheng-Chung

    2006-03-01

    A new basic structure of a dispersive-compensation filter, called a chirped-cavity dispersion-compensator (CCDC) filter, was designed to offer the advantages of small ripples in both reflectance and group-delay dispersion (GDD). This filter provides a high dispersion compensation, like the Gires-Tournois interferometer (GTI) filter, and a wide working bandwidth, like the chirped mirror (CM). The structure of the CCDC is a cavity-type Fabry-Perot filter with a spacer layer (2 mH or 2 mL) and a chirped high reflector. The CCDC filter can provide a negative GDD of -50 fs2 over a bandwidth of 56 THz with half the optical thickness of the CM or the GTI.

  4. Novel Ion Trap Design for Strong Ion-Cavity Coupling

    Directory of Open Access Journals (Sweden)

    Alejandro Márquez Seco

    2016-04-01

    Full Text Available We present a novel ion trap design which facilitates the integration of an optical fiber cavity into the trap structure. The optical fibers are confined inside hollow electrodes in such a way that tight shielding and free movement of the fibers are simultaneously achievable. The latter enables in situ optimization of the overlap between the trapped ions and the cavity field. Through numerical simulations, we systematically analyze the effects of the electrode geometry on the trapping characteristics such as trap depths, secular frequencies and the optical access angle. Additionally, we simulate the effects of the presence of the fibers and confirm the robustness of the trapping potential. Based on these simulations and other technical considerations, we devise a practical trap configuration that isviable to achieve strong coupling of a single ion.

  5. Resonant cavity light-emitting diodes: modeling, design, and optimization

    Science.gov (United States)

    Dumitrescu, Mihail M.; Sipila, Pekko; Vilokkinen, Ville; Toikkanen, L.; Melanen, Petri; Saarinen, Mika J.; Orsila, Seppo; Savolainen, Pekka; Toivonen, Mika; Pessa, Markus

    2000-02-01

    Monolithic top emitting resonant cavity light-emitting diodes operating in the 650 and 880 nm ranges have been prepared using solid-source molecular beam epitaxy growth. Transfer matrix based modeling together with a self- consistent model have been sued to optimize the devices' performances. The design of the layer structure and doping profile was assisted by computer simulations that enabled many device improvements. Among the most significant ones intermediate-composition barrier-reduction layers were introduced in the DBR mirrors for improving the I-V characteristics and the cavity and mirrors were detuned aiming at maximum extraction efficiency. The fabricated devices showed line widths below 15 nm, CW light power output of 8 and 22.5 mW, and external quantum efficiencies of 3 percent and 14.1 percent in the 650 nm and 880 nm ranges, respectively - while the simulations indicate significant performance improvement possibilities.

  6. Accurate Die Design for Automotive Panel Stamping Considering the Compensation Related with Die Deflection and Blank Thinning

    Science.gov (United States)

    Chen, Jun; Xu, Dongkai; Xia, Guodong; Li, Xifeng; Chen, Jieshi; Zhang, Jian; Yan, Wei; Li, Yue

    2011-08-01

    In order to improve assembly accuracy, automotive body panels have to be fabricated with higher dimensional and surface quality requirements, therefore the die faces should be designed more accurately to consider more relevant factors. In the presented study, we proposed algorithms to realize the following functions: through forming process simulation, the thinning distribution on the deformed blank was extracted as first kind of compensation; through die structural CAE analysis which automatically mapped the boundary contact forces onto the die surfaces from process simulation results, the die deflection was calculated as second kind of compensation. These two quantitative contributions were added together to compensate the die face. The proposed methodologies were programmed and integrated with LS-Dyna and HyperWorks, and also integrated with Autoform and CATIA linear CAE functionalities separately. In addition, a software toolkit to calculate the contacting ratio was also developed to evaluate the effectiveness of die face compensation. The second toolkit developed was verified by an automotive structural part forming die design, through die compensation and geometric optimization, the predicted contact ratio between the die face and formed blank was improved a lot, and the first toolkit was testified by a fender drawing die design. It shows that the die face compensation can be realized and integrated seamlessly between CAD model, process simulation model and die structural CAE model with the help of data I/O tools developed by the authors.

  7. Optimization of Helium Vessel Design for ILC Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Fratangelo, Enrico [Univ. of Pisa (Italy)

    2009-01-01

    certify the compliance of the Helium vessel and the cavity to the ASME code standard. After briefly recalling to the main contents of the the ASME Code (Sections II and Vlll - Division ll), the procedure used for finding all relevant stresses and comparing the obtained results with the maximum values allowed are explained. This part also includes the buckling verification of the cavity. In Chapter 5 the manufacturing process of the cavity end-caps, whose function is to link the Helium vessel with the cavity, is studied. The present configuration of the dies is described and the manufacturing process is simulated in order to explain the origin of some defects fol.llld on real parts. Finally a new design of the dies is proposed and the resulting deformed piece is compared with the design requirements. Chapter 6 describes a finite elements analysis to assess the efficiency and the stiffness of the Helium vessel. Furthermore the results of the optimization of the Helium vessel (in order to increase the value of the efficiency) are reported. The same stiffness analysis is used in Chapter 7 for the Blade-Tuner study. After a description of this tuner and of its function, the preliminary analyses done to confirm the results provided by the vendor are described and then its limiting load conditions are found. Chapter 8 shows a study of the resistance of all the welds present in between the cavity and the end-cap and between the end-caps and the He vessel for a smaller superconducting cavity operating at 3.9 GHz. Finally Chapter 9 briefly describes some R&D activities in progress at INFN (Section of Pisa) and Fermilab that could produce significant cost reductions of the Helium vessel design. All the finite elements analyses contained and described in this thesis made possible the certification of the whole superconducting cavity-Helium vessel assembly at Fermilab. Furthermore they gave several useful indications to the Fermilab staff to improve the performance of the Helium

  8. Photoinjector RF cavity design for high power CW FEL

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S. (Sergey); Schrage, D. L. (Dale L.); Wood R. L. (Richard L.); Young, L. M. (Lloyd M.); Schultheiss, T. (Thomas); Christina, V.; Rathke, J. (John)

    2002-01-01

    The project is under way to develop a key enabling technology for high-power CW FEL: an RF photoinjector capable of producing continuous average current greater than 100 mA. The specific aim is a 700 MHz pi-mode, normal-conducting RF photoinjector, 3 nC of bunch charge, 100 mA of current (at 33.3-MHz bunch repetition rate) and emittance less than 10 mm-mrad. This level of performance will enable robust 100-kW-class FEL operation with electron beam energy 400 MeV, thereby reducing the size and cost of the FEL. This design is scalable to the MW power level by increasing the electron bunch repetition rate from 33.3 MHz to a higher value. The major challenges are emittance control and high heat flux within the CW 700-MHz RF cavities. Results of RF cavity design and cooling schemes are presented, including both high-velocity water and liquid nitrogen cooling options.

  9. Analysis and Design of Vertical Cavity Surface Emitting Lasers

    Science.gov (United States)

    Yu, S. F.

    2003-08-01

    A practical, hands-on guidebook for the efficient modeling of VCSELs Vertical Cavity Surface Emitting Lasers (VCSELs) are a unique type of semiconductor laser whose optical output is vertically emitted from the surface as opposed to conventional edge-emitting semiconductor lasers. Complex in design and expensive to produce, VCSELs nevertheless represent an already widely used laser technology that promises to have even more significant applications in the future. Although the research has accelerated, there have been relatively few books written on this important topic. Analysis and Design of Vertical Cavity Surface Emitting Lasers seeks to encapsulate this growing body of knowledge into a single, comprehensive reference that will be of equal value for both professionals and academics in the field. The author, a recognized expert in the field of VCSELs, attempts to clarify often conflicting assumptions in order to help readers achieve the simplest and most efficient VCSEL models for any given problem. Highlights of the text include: * A clear and comprehensive theoretical treatment of VCSELs * Detailed derivations for understanding the operational principles of VCSELs * Mathematical models for the investigation of electrical, optical, and thermal properties of VCSELs * Case studies on the mathematical modeling of VCSELs and the implementation of simulation programs

  10. Optimal design of radial Bragg cavities and lasers.

    Science.gov (United States)

    Ben-Bassat, Eyal; Scheuer, Jacob

    2015-07-01

    We present a new and optimal design approach for obtaining maximal confinement of the field in radial Bragg cavities and lasers for TM polarization. The presented approach outperforms substantially the previously employed periodic and semi-periodic design schemes of such lasers. We show that in order to obtain maximal confinement, it is essential to consider the complete reflection properties (amplitude and phase) of the propagating radial waves at the interfaces between Bragg layers. When these properties are taken into account, we find that it is necessary to introduce a wider ("half-wavelength") layer at a specific radius in the "quarter-wavelength" radial Bragg stack. It is shown that this radius corresponds to the cylindrical equivalent of Brewster's angle. The confinement and field profile are calculated numerically by means of transfer matrix method.

  11. Novel Geometries for the LHC Crab Cavity

    Energy Technology Data Exchange (ETDEWEB)

    B. Hall, G. Burt, C. Lingwood, R. Rimmer, H. Wang

    2010-05-23

    The planned luminosity upgrade to LHC is likely to necessitate a large crossing angle and a local crab crossing scheme. For this scheme crab cavities align bunches prior to collision. The scheme requires at least four such cavities, a pair on each beam line either side of the interaction point (IP). Upstream cavities initiate rotation and downstream cavities cancel rotation. Cancellation is usually done at a location where the optics has re-aligned the bunch. The beam line separation near the IP necessitates a more compact design than is possible with elliptical cavities such as those used at KEK. The reduction in size must be achieved without an increase in the operational frequency to maintain compatibility with the long bunch length of the LHC. This paper proposes a suitable superconducting variant of a four rod coaxial deflecting cavity (to be phased as a crab cavity), and presents analytical models and simulations of suitable designs.

  12. Cryogenic Test of Double Quarter Wave Crab Cavity for the LHC High Luminosity Upgrade

    CERN Document Server

    Xiao, B; Belomestnykh, S; Ben-Zvi, I; Calaga, Rama; Cullen, C; Capatina, Ofelia; Hammons, L; Li, Z; Marques, C; Skaritka, J; Verdú-Andres, S; Wu, Q

    2015-01-01

    A Proof-of-Principle (PoP) Double Quarter Wave Crab Cavity (DQWCC) was designed and fabricated for the Large Hadron Collider (LHC) luminosity upgrade. A vertical cryogenic test has been done at Brookhaven National Lab (BNL). The cavity achieved 4.5 MV deflecting voltage with a quality factor above 3×109 . We report the test results of this design.

  13. Concurrent mechatronic design approach for active control of cavity noise

    Science.gov (United States)

    de Oliveira, L. P. R.; da Silva, M. M.; Sas, P.; Van Brussel, H.; Desmet, W.

    2008-07-01

    Active control is a potential solution to many noise and vibration problems for improving the low-frequency performance. Cavity noise reduction as encountered for instance in aircraft cabins and vehicle interiors is a typical example. However, the conventional design of these active solutions may lead to suboptimal products, since the interaction between the vibro-acoustic plant dynamics and control dynamics is usually not considered. A proper way to design such active systems would be considering control and plant parameters concurrently. To cope with this approach, a methodology to derive a fully coupled mechatronic model that deals with both the vibro-acoustic plant dynamics as well as the control parameters is proposed. The inclusion of sensor and actuator models is investigated, since it contributes to the model accuracy as it can confer frequency, phase or amplitude limitations to the control performance. The proposed methodology provides a reduced state-space model derived from a fully coupled vibro-acoustic finite element model. Experimental data on a vibro-acoustic vehicle cabin mock-up are used to validate the model reduction procedure. Regarding noise reduction, optimization results are presented considering both vibro-acoustic plant features, such as thicknesses, and control parameters, such as sensor and actuator placement and control gains. A collocated sensor/actuator pair is considered in a velocity feedback control strategy. The benefits of a concurrent mechatronic design when dealing with active structural-acoustic control solutions are addressed, illustrated and experimentally validated.

  14. Cavity design and linear analysis of 225 GHz frequency-quadrupling gyroklystron

    Institute of Scientific and Technical Information of China (English)

    Liu Di-Wei; Yuan Xue-Song; Yan Yang; Liu Sheng-Gang

    2009-01-01

    This paper considers the frequency-quadrupling three-cavity gyroklystrons with successive frequency-doubling in each cavity. The cavities of 225 GHz frequency-quadrupling gyroklystron are designed with the scattering matrices method and the possible operating mode are discussed. With the point-gap theory, the starting currents of the possible operating modes and the potential parasitic modes in the output cavity are calculated. The optimal operating mode is proposed under consideration of the mode competition and the power capacity of the cavity.

  15. Decreased vibrational susceptibility of Fabry-Perot cavities via designs of geometry and structural support

    Institute of Scientific and Technical Information of China (English)

    Yang Tao; Li Wen-Bo; Zang Er-Jun; Chen Li-Sheng

    2007-01-01

    Ultra-stable optical cavities are widely used for laser frequency stabilization. In these experiments the laser performance relies on the length stability of the Fabry-Perot cavities. Vibration-induced deformation is one of the dominant factors that affect the stability of ultra-stable optical cavities. We have quantitatively analysed the elastic deformation of Fabry-Perot cavities with various shapes and mounting configurations. Our numerical result facilitates a novel approach for the design of ultra-stable cavities that are insensitive to vibrational perturbations. This approach can be applied to many experiments such as laser frequency stabilization, high-precision laser spectroscopy, and optical frequency standards.

  16. Design and prototyping of HL-LHC double quarter wave crab cavities for SPS test

    Energy Technology Data Exchange (ETDEWEB)

    Verdu-Andres, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Skaritka, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Wu, Q. [Brookhaven National Lab. (BNL), Upton, NY (United States); Xiao, B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Belomestnykh, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stony Brook Univ., NY (United States); Ben-Zvi, I. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stony Brook Univ., NY (United States); Alberty, L. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Artoos, K. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Calaga, R. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Capatina, O. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Capelli, T. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Carra, F. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Leuxe, R. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Kuder, N. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Zanoni, C. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Li, Z. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Ratti, A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-05-03

    The LHC high luminosity project envisages the use of the crabbing technique for increasing and levelling the LHC luminosity. Double Quarter Wave (DQW) resonators are compact cavities especially designed to meet the technical and performance requirements for LHC beam crabbing. Two DQW crab cavities are under fabrication and will be tested with beam in the Super Proton Synchrotron (SPS) at CERN by 2017. This paper describes the design and prototyping of the DQW crab cavities for the SPS test.

  17. Design and Prototyping of HL-LHC Double Quarter Wave Crab Cavities for SPS Test

    CERN Document Server

    Verdú-Andrés, S; Wu, Q; Xiao, B P; Belomestnykh, S; Ben-Zv, I; Alberty, L; Artoos, Kurt; Calaga, Rama; Capatina, Ofelia; Capelli, Teddy; Carra, Federico; Leuxe, Raphael; Kuder, Norbert; Zanoni, Carlo; Li, Z; Ratti, A

    2015-01-01

    The LHC high luminosity project envisages the use of the crabbing technique for increasing and levelling the LHC luminosity. Double Quarter Wave (DQW) resonators are compact cavities especially designed to meet the technical and performance requirements for LHC beam crabbing. Two DQW crab cavities are under fabrication and will be tested with beam in the Super Proton Synchrotron (SPS) at CERN by 2017. This paper describes the design and prototyping of the DQW crab cavities for the SPS test.

  18. Design of a folded, multi-pass Fabry–Perot cavity for displacement metrology

    NARCIS (Netherlands)

    Joo, K.M.; Ellis, J.D.; Spronck, J.W.; Munnig Schmidt, R.H.

    2009-01-01

    We present a folded, multi-pass cavity design for displacement measuring Fabry–Perot interferometry. The cavity length is designed to be one-quarter of the physical length needed for a typical Fabry–Perot interferometer by using a quarter-wave plate and a retroreflector. This enhances the displaceme

  19. Mechanical Design of a New Injector Cryomodule 2-Cell Cavity at CEBAF

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Guangfeng G. [JLAB; Henry, James E. [JLAB; Mammosser, John D. [JLAB; Rimmer, Robert A. [JLAB; Wang, Haipeng [JLAB; Wiseman, Mark A. [JLAB; Yang, Shuo [JLAB

    2013-12-01

    As a part of Jefferson Lab’s 12 GeV upgrade, a new injector superconducting RF cryomodule is required. This unit consists of a 2-cell and 7-cell cavity, with the latter being refurbished from an existing cavity. The new 2-cell cavity requires electromagnetic design and optimization followed by mechanical design analyses. The electromagnetic design is reported elsewhere. This paper aims to present the procedures and conclusions of the analyses on cavity tuning sensitivity, pressure sensitivity, upset condition pressure induced stresses, and structural vibration frequencies. The purposes of such analyses include: 1) provide reference data for cavity tuner design; 2) examine the structural integrity of the cavity; and 3) evaluate the 2-cell cavity’s resistance to microphonics. Design issues such as the location of stiffening rings, effect of tuner stiffness on cavity stress, choice of cavity wall thickness, etc. are investigated by conducting extensive finite element analyses. Progress in fabrication of the 2-cell cavity is also reported.

  20. Design of radio-frequency cavities and Tera-Hertz electron injectors for advanced applications

    Energy Technology Data Exchange (ETDEWEB)

    Seyedfakhari, Seyedmoein

    2016-06-15

    Design of three accelerator components including a buncher cavity for REGAE, a normal conducting cavity for arrival time stabilization at FLASH and ultra-fast guns for the AXSIS project is presented in this thesis. Using RF cavities caused a revolution in accelerators and made it possible to generate high energy particle beams. In advanced accelerators, cavities are not only used to increase the particle energy but they are also widely used to improve the beam quality and additionally for beam diagnostic purposes. In the present dissertation, such applications are discussed. First, design of a buncher cavity which compresses the bunch at the REGAE facility is presented. The design pursues improving the mode separation of the cavity. The simulation result illustrates that the difference between the operating mode and its adjacent mode has been increased from 2 MHz for the existing cavity to 9.5 MHz for the new design. In the second part, a normal conducting cavity is discussed, which will be used to regulate the arrival time ofthe bunches at FLASH and at the European XFEL. The designed cavity is able to correct the arrival time jitter of ± 150 fs in order to provide femtosecond precision synchronization between the electron beam and the external laser pulses. Thermal, wakefield and multipacting simulations have also been performed for the designed cavity in order to evaluate its operation efficiency. In advanced accelerators however RF cavities should be replaced by novel structures to accelerate the particles in shorter distances using higher operating frequency. To this end, ultra-fast guns are designed which will be discussed in the last part of this work. The designed guns accelerate the electrons from their rest mass up to 2 MeV using a single cycle THz signal with a total energy of 2 mJ.

  1. Study of Sweep and Induced Dihedral Effects in Subsonic Axial Flow Compressor Passages—Part I: Design Considerations—Changes in Incidence, Deflection, and Streamline Curvature

    Directory of Open Access Journals (Sweden)

    P. V. Ramakrishna

    2009-01-01

    Full Text Available This article presents the study of Tip Chordline Sweeping (TCS and Axial Sweeping (AXS of low-speed axial compressor rotor blades against the performance of baseline unswept rotor (UNS for different tip clearance levels. The first part of the paper discusses the changes in design parameters when the blades are swept, while the second part throws light on the effect of sweep on tip leakage flow-related phenomena. 15 domains are studied with 5 sweep configurations (0∘, 20∘ TCS, 30∘ TCS, 20∘ AXS, and 30∘ AXS and for 3 tip clearances (0.0%, 0.7%, and 2.7% of the blade chord. A commercial CFD package is employed for the flow simulations and analysis. Results are well validated with experimental data. Forward sweep reduced the flow incidences. This is true all over the span with axial sweeping while little higher incidences below the mid span are observed with tip chordline sweeping. Sweeping is observed to lessen the flow turning. AXS rotors demonstrated more efficient energy transfer among the rotors. Tip chordline sweep deflected the flow towards the hub while effective positive dihedral induced with axial sweeping resulted in outward deflection of flow streamlines. These deflections are more at lower mass flow rates.

  2. Design of a Cavity of Drift Tube Linac

    Institute of Scientific and Technical Information of China (English)

    WANG; Xiu-long; LV; Wei-xing; LI; Jin-hai; HUANG; Jun; WU; Qing-feng

    2013-01-01

    The drift tube Linac(DTL)is used as accelerating of low energy proton beam with high intensity.Its operating frequency is 325 MHz with handling power of 2.5 kW.The cavity of DTL consists of circularwaveguide,drift tube,post coupler and tuner.First,the beam parameters of the cavity of DTL is calculated by using beam dynamic codes,and then the electromagnetic field distribution and RF parameters of the cavity of DTL is calculated by using

  3. Inverse-problem approach to designing photonic crystals for cavity QED experiments.

    Science.gov (United States)

    Geremia, J M; Williams, Jon; Mabuchi, Hideo

    2002-12-01

    Photonic band gap (PBG) materials are attractive for cavity QED experiments because they provide extremely small mode volumes and are monolithic, integratable structures. As such, PBG cavities are a promising alternative to Fabry-Perot resonators. However, the cavity requirements imposed by QED experiments, such as the need for high Q (low cavity damping) and small mode volumes, present significant design challenges for photonic band gap materials. Here, we pose the PBG design problem as a mathematical inversion and provide an analytical solution for a two-dimensional (2D) crystal. We then address a planar (2D crystal with finite thickness) structure using numerical techniques.

  4. PAL-XFEL cavity beam position monitor pick-up design and beam test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sojeong, E-mail: sojung8681@postech.ac.kr; Park, Young Jung; Kim, Changbum; Kim, Seung Hwan; Shin, Dong Cheol; Han, Jang-Hui; Ko, In Soo

    2016-08-11

    As an X-ray Free Electron Laser, PAL-XFEL is about to start beam commissioning. X-band cavity beam position monitor (BPM) is used in the PAL-XFEL undulator beam line. Prototypes of cavity BPM pick-up were designed and fabricated to test the RF characteristics. Also, the beam test of a cavity BPM pick-up was done in the Injector Test Facility (ITF). In the beam test, the raw signal properties of the cavity BPM pick-up were measured at a 200 pC bunch charge. According to the RF test and beam test results, the prototype cavity BPM pick-up design was confirmed to meet the requirements of the PAL-XFEL cavity BPM system.

  5. Design of EPU oscillator cavity in femtosecond accelerator

    Institute of Scientific and Technical Information of China (English)

    BEI Hua; DENG Hai-Xiao; DAI Zhi-Min

    2009-01-01

    We adopt the groove guide as the cavity of the undulator to reduce the diffraction effect.The groove guide has the advantages of lower surface energy loss,larger power capacity,less modes,and larger structure dimension over the traditional method waveguide.The attenuation calculation is given in this paper including the cavity optimization.And the dispersive character indicates that the oscillator can work in different modes with the change of the electron beam energy.

  6. Mechanical design and fabrication processes for the ALS third-harmonic cavities

    Energy Technology Data Exchange (ETDEWEB)

    Franks, M; Henderson, T; Hernandez, K; Otting, D; Plate, D; Rimmer, R

    1999-03-25

    It is planned to install five third-harmonic (1.5 GHz) RF Cavities in May/June 1999 as an upgrade to the Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory (LBNL). This paper presents mechanical design features, their experiences in using electronic design models to expedite the manufacturing process, and the fabrication processes employed to produce these cavities for the ALS. They discuss some of the lessons learned from the PEP-II RF Cavity design and fabrication, and outline the improvements incorporated in the new design. They also report observations from the current effort.

  7. Conformal optimal design and processing of extruding die cavity

    Institute of Scientific and Technical Information of China (English)

    齐红元; 陈科山; 杜凤山

    2008-01-01

    Aimed at the optimal analysis and processing technology of die cavity of special-shaped products extrusion, by numerical analysis of trigonometric interpolation and Conformal Mapping theory, on the non-circle cross-section of special-shaped products, the conformal mapping function can be set up to translate the cross-section region into unit dish region, over numerical finite interpolation points between even and odd. Products extrusion forming can be turned into two-dimension problem, and plastic stream function can be deduced, as well as the mathematical model of the die cavity surface is established based on deferent kinds of vertical curve. By applying Upper-bound Principle, the vertical curves and related parameters of die cavity are optimized. Combining with electrical discharge machining (EDM) process and numerical control (NC) milling machine technology, the optimal processing of die cavity can be realized. Taking ellipse-shaped products as an instance, the optimal analysis and processing of die cavity including extruding experiment are carried out.

  8. Design and cold test of S-BAND cavity BPM for HLS

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    An S-band cavity BPM is designed for a new injector in National Synchrotron Radiation Laboratory. A re-entrant position cavity is tuned to the TM110 mode as position cavity. Cut-through waveguides are used as pickups to suppress the monopole signal. Theoretical resolution of this design is 31 nm. A prototype cavity BPM system is manufactured for off-line cold tests. The wire scanning method is used to calibrate the BPM and estimate the performance of the on-line BPM system. A cross-talk problem has been detected during the cold test. Racetrack cavity BPM design can be used to suppress the cross-talk. With the nonlinear effect being ignored, transform matrix can be used to correct cross-talk. Analysis of cold test results shows that the position resolution of prototype BPM is better than 3 μm.

  9. Designing and Dosimetry of a Shield for Photon Fields of Radiation Therapy in Oral Cavity Cancer

    OpenAIRE

    Jabbari, Keyvan; Senobari, Somayeh; Roayaei, Mahnaz; Rostampour, Masoumeh

    2015-01-01

    The cancer of oral cavity is related to lesions of mucous membrane of tongue and gum that can be treated with radiation therapy. A lateral photon field can be used to treat this kind of tumor, which has a side-effect on normal tissue in the opposite side of the oral cavity. In this study the dosimetric effect of the various shields in oral cavity is evaluated. In this study, a special phantom similar to the structure of oral cavity with capability of film dosimetry was designed and constructe...

  10. Novel Geometries for the LHC Crab Cavity

    Energy Technology Data Exchange (ETDEWEB)

    Hall, B. [Lancaster Univ. (United Kingdom); Burt, G. [Lancaster Univ. (United Kingdom); Smith, J. D.A. [Lancaster Univ. (United Kingdom); Rimmer, R. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Wang, H. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Delayen, J. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Calaga, R. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2009-05-01

    In 2017 the LHC is envisioned to increase its luminosity via an upgrade. This upgrade is likely to require a large crossing angle hence a crab cavity is required to align the bunches prior to collision. There are two possible schemes for crab cavity implementation, global and local. In a global crab cavity the crab cavity is far from the IP and the bunch rotates back and forward as it traverses around the accelerator in a closed orbit. For this scheme a two-cell elliptical squashed cavity at 800 MHz is preferred. To avoid any potential beam instabilities all the parasitic modes of the cavities must be damped strongly, however crab cavities have lower order and same order modes in addition to the usual higher order modes and hence a novel damping scheme must be used to provide sufficient damping of these modes. In the local scheme two crab cavities are placed at each side of the IP two start and stop rotation of the bunches. This would require crab cavities much smaller transversely than in the global scheme but the frequency cannot be increased any higher due to the long bunch length of the LHC beam. This will require a novel compact crab cavity design. A superconducting version of a two rod coaxial deflecting cavity as a suitable design is proposed in this paper.

  11. Design and Performance of a Three-Cavity Gyroklystron Amplifier,

    Science.gov (United States)

    1986-04-01

    earliest work which specifically addresses gyroklvstrons is that of Demidovich .1 He calculated the perpendicular efficiency (the efficiency with which... Demidovich , I. S. Kovalev, A. A. Kurayev, and F. G. Shevchenko, "Efficiency-Optimized Output Cavity Profiles that Provide a Higher Margin of Gyroklvstron

  12. High beta lasing in micropillar cavities with adiabatic layer design

    DEFF Research Database (Denmark)

    Lermer, M.; Gregersen, Niels; Lorke, M.;

    2013-01-01

    We report on lasing in optically pumped adiabatic micropillar cavities, based on the AlAs/GaAs material system. A detailed study of the threshold pump power and the spontaneous emission β factor in the lasing regime for different diameters dc is presented. We demonstrate a reduction of the thresh...

  13. RF Design of Normal Conducting 704 MHz and 2.1 GHz Cavities for LEReC Linac

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Binping [Brookhaven Natl. Lab.; Belomestnykh, Sergey [SUNY, Stony Brook; Ben-Zvi, Ilan [RIKEN BNL; Blaskiewicz, Michael [RIKEN BNL; Brennan, Joseph [RIKEN BNL; Brutus, Jean Clifford [RIKEN BNL; Fedotov, Alexei [RIKEN BNL; Hahn, Harald [Brookhaven; McIntyre, Gary [RIKEN BNL; Pai, Chien [RIKEN BNL; Smith, Kevin [RIKEN BNL; Tuozzolo, Joseph [RIKEN BNL; Veshcherevich, Vadim [Cornell U., CLASSE; Wu, Qiong [RIKEN BNL; Xin, Tianmu [RIKEN BNL; Xu, Wencan [RIKEN BNL; Zaltsman, Alex [RIKEN BNL

    2016-06-01

    To improve RHIC luminosity for heavy ion beam energies below 10 GeV/nucleon, the Low Energy RHIC electron Cooler (LEReC) is currently under development at BNL. Two normal conducting cavities, a single cell 704 MHz cavity and a 3 cell 2.1 GHz third harmonic cavity, will be used in LEReC for energy spread correction. Currently these two cavities are under fabrication. In this paper we report the RF design of these two cavities.

  14. A novel electromagnetic design and a new manufacturing process for the cavity BPM (Beam Position Monitor)

    Science.gov (United States)

    Dal Forno, Massimo; Craievich, Paolo; Baruzzo, Roberto; De Monte, Raffaele; Ferianis, Mario; Lamanna, Giuseppe; Vescovo, Roberto

    2012-01-01

    The Cavity Beam Position Monitor (BPM) is a beam diagnostic instrument which, in a seeded Free Electron Laser (FEL), allows the measurement of the electron beam position in a non-destructive way and with sub-micron resolution. It is composed by two resonant cavities called reference and position cavity, respectively. The measurement exploits the dipole mode that arises when the electron bunch passes off axis. In this paper we describe the Cavity BPM that has been designed and realized in the context of the FERMI@Elettra project [1]. New strategies have been adopted for the microwave design, for both the reference and the position cavities. Both cavities have been simulated by means of Ansoft HFSS [2] and CST Particle Studio [3], and have been realized using high precision lathe and wire-EDM (Electro-Discharge) machine, with a new technique that avoids the use of the sinker-EDM machine. Tuners have been used to accurately adjust the working frequencies for both cavities. The RF parameters have been estimated, and the modifications of the resonant frequencies produced by brazing and tuning have been evaluated. Finally, the Cavity BPM has been installed and tested in the presence of the electron beam.

  15. A novel electromagnetic design and a new manufacturing process for the cavity BPM (Beam Position Monitor)

    Energy Technology Data Exchange (ETDEWEB)

    Dal Forno, Massimo, E-mail: massimo.dalforno@phd.units.it [Department of Industrial Engineering and Information Technology, University of Trieste (Italy); Craievich, Paolo, E-mail: paolo.craievich@elettra.trieste.it [Sicrotrone Trieste S.C.p.A., Basovizza, Trieste (Italy); Baruzzo, Roberto [Cinel Strumenti Scientifici s.r.l., Vigonza, Padova (Italy); De Monte, Raffaele; Ferianis, Mario [Sicrotrone Trieste S.C.p.A., Basovizza, Trieste (Italy); Lamanna, Giuseppe [Cinel Strumenti Scientifici s.r.l., Vigonza, Padova (Italy); Vescovo, Roberto [Department of Industrial Engineering and Information Technology, University of Trieste (Italy)

    2012-01-11

    The Cavity Beam Position Monitor (BPM) is a beam diagnostic instrument which, in a seeded Free Electron Laser (FEL), allows the measurement of the electron beam position in a non-destructive way and with sub-micron resolution. It is composed by two resonant cavities called reference and position cavity, respectively. The measurement exploits the dipole mode that arises when the electron bunch passes off axis. In this paper we describe the Cavity BPM that has been designed and realized in the context of the FERMI-Elettra project . New strategies have been adopted for the microwave design, for both the reference and the position cavities. Both cavities have been simulated by means of Ansoft HFSS and CST Particle Studio , and have been realized using high precision lathe and wire-EDM (Electro-Discharge) machine, with a new technique that avoids the use of the sinker-EDM machine. Tuners have been used to accurately adjust the working frequencies for both cavities. The RF parameters have been estimated, and the modifications of the resonant frequencies produced by brazing and tuning have been evaluated. Finally, the Cavity BPM has been installed and tested in the presence of the electron beam.

  16. Design of a C-band relativistic extended interaction klystron with coaxial output cavity

    Institute of Scientific and Technical Information of China (English)

    WU Yang; ZHAO De-Kui; CHEN Yong-Dong

    2015-01-01

    In order to overcome the disadvantages of conventional high frequency relativistic klystron amplifiers in power capability and RF conversion efficiency,a C-band relativistic extended interaction klystron amplifier with coaxial output cavity is designed with the aid of PIC code MAGIC.In the device,disk-loaded cavities are introduced in the input and intermediate cavity to increase the beam modulation depth,and a coaxial disk-loaded cavity is employed in the output cavity to enhance the RF conversion efficiency.In PIC simulation,when the beam voltage is 680 kV and current is 4 kA,the device can generate 1.11 GW output power at 5.64 GHz with an efficiency of 40.8%.

  17. First Considerations Concerning an Optimized Cavity Design for the Main Linac of BERLinPro

    Energy Technology Data Exchange (ETDEWEB)

    B. Riemann, T. Weis, W. Anders, J. Knobloch, A. Neumann, H.-W. Glock, C. Potratz, U. van Rienen, F. Marhauser

    2011-09-01

    The Berlin Energy Recovery Linac Project (BERLinPro) is designed to develop and demonstrate CW linac technology and expertise required to drive next-generation Energy Recovery Linacs. Strongly HOM-damped multicell 1.3 GHz cavities are required for the main linac. The optimization of the cavities presented here is primarily based on the CEBAF 1.5 GHz 5-cell high-current cavity design, including HOM waveguide couplers. The cavity was scaled to 1.3 GHz and extended to 7 cells. Modifications to the end group design have also been studied. An effort was also made to reduce the ratio Epk/Eacc while still permitting HOMs to propagate.

  18. Design of a multi beam klystron cavity from its single beam parameters

    Energy Technology Data Exchange (ETDEWEB)

    Kant, Deepender, E-mail: dkc@ceeri.ernet.in; Joshi, L. M. [CSIR-Central Electronics Engineering Research Institute, Pilani (India); Janyani, Vijay [Department of ECE, MNIT, Jaipur (India)

    2016-03-09

    The klystron is a well-known microwave amplifier which uses kinetic energy of an electron beam for amplification of the RF signal. There are some limitations of conventional single beam klystron such as high operating voltage, low efficiency and bulky size at higher power levels, which are very effectively handled in Multi Beam Klystron (MBK) that uses multiple low purveyance electron beams for RF interaction. Each beam propagates along its individual transit path through a resonant cavity structure. Multi-Beam klystron cavity design is a critical task due to asymmetric cavity structure and can be simulated by 3D code only. The present paper shall discuss the design of multi beam RF cavities for klystrons operating at 2856 MHz (S-band) and 5 GHz (C-band) respectively. The design approach uses some scaling laws for finding the electron beam parameters of the multi beam device from their single beam counter parts. The scaled beam parameters are then used for finding the design parameters of the multi beam cavities. Design of the desired multi beam cavity can be optimized through iterative simulations in CST Microwave Studio.

  19. Engineering of a Superconducting 400 MHz Crabbing Cavity for the LHC HiLumi Upgrade

    CERN Document Server

    Gorelov, D; De Silva, S U; Delayen, Jean Roger

    2012-01-01

    The recently developed new simplified design for the 400 MHz LHC crabbing cavity presents attractive properties compared to conventional designs. The proposed approach can be equally compact in both transverse dimensions and allows horizontal as well as vertical deflection of the beam in the collider. The significant modification of the parallel-bar design with the bars merged to the side walls of the cavity gives improved properties, such as better mode separation and reduced surface fields*. A transverse deflecting voltage of 3 to 5 MV in a single cavity can be expected with the peak surface electric field lower then 50 MV/m and peak magnetic field below 100 mT. This paper presents engineering issues of the proof-of-concept crabbing cavity d esign and discusses the manufacturing techniques. The paper discusses present status of the project including fabrication of the niobium cavity, as well as room temperature and cryogenic testing.

  20. Base deflection and microleakage of composite restorations.

    Science.gov (United States)

    Paulillo, L A; de Goes, M F; Consani, S

    1994-06-01

    The flexural deflections of human dentin, Herculite XR, Dycal, Vidrion F, zinc phosphate base, and combinations of composite-base were determined. The influence of the flexural deflections in the marginal microleakage was also determined for the composite-base combinations. The flexural deflection test for dentin showed no statistically significant differences between the two floor cavity depths studied. There were significant differences among cements when the thickness of the base was 1 mm whereas no differences occurred at 2 mm. The composite-base combinations did not present statistical differences. There were no statistically significant differences in the microleakage levels among loaded and non-loaded specimens; however, dye penetration was visually greater in loaded samples.

  1. Design of plasmonic photonic crystal resonant cavities for polarization sensitive infrared photodetectors

    Science.gov (United States)

    Rosenberg, Jessie; Shenoi, Rajeev V.; Krishna, Sanjay; Painter, Oskar

    2010-02-01

    We design a polarization-sensitive resonator for use in midinfrared photodetectors, utilizing a photonic crystal cavity and a single or double-metal plasmonic waveguide to achieve enhanced detector efficiency due to superior optical confinement within the active region. As the cavity is highly frequency and polarization-sensitive, this resonator structure could be used in chip-based infrared spectrometers and cameras that can distinguish among different materials and temperatures to a high degree of precision.

  2. Design of optomechanical cavities and waveguides on a simultaneous bandgap phononic-photonic crystal slab.

    Science.gov (United States)

    Safavi-Naeini, Amir H; Painter, Oskar

    2010-07-05

    In this paper we study and design quasi-2D optomechanical crystals, waveguides, and resonant cavities formed from patterned slabs. Two-dimensional periodicity allows for in-plane pseudo-bandgaps in frequency where resonant optical and mechanical excitations localized to the slab are forbidden. By tailoring the unit cell geometry, we show that it is possible to have a slab crystal with simultaneous optical and mechanical pseudo-bandgaps, and for which optical waveguiding is not compromised. We then use these crystals to design optomechanical cavities in which strongly interacting, co-localized photonic-phononic resonances occur. A resonant cavity structure formed by perturbing a ;;linear defect' waveguide of optical and acoustic waves in a silicon optomechanical crystal slab is shown to support an optical resonance at wavelength lambda(0) approximately 1.5 mum and a mechanical resonance of frequency omega(m)/2pi approximately 9.5 GHz. These resonances, due to the simultaneous pseudo-bandgap of the waveguide structure, are simulated to have optical and mechanical radiation-limited Q-factors greater than 10(7). The optomechanical coupling of the optical and acousticresonances in this cavity due to radiation pressure is also studied, with a quantum conversion rate, corresponding to the scattering rate of a single cavity photon via a single cavity phonon, calculated to be g/2pi = 292 kHz.

  3. Design and simulation of a new type of 500 MHz single-cell superconducting RF cavity

    Institute of Scientific and Technical Information of China (English)

    LU Chang-Wang; ZHANG Zhi-Gang; ZHENG Xiang; WEI Ye-Long; YU Hai-Bo; LI Zheng; XU Kai; LIU Jian-Fei; HOU Hong-Tao; MA Zhen-Yu; MAO Dong-Qing; FENG Zi-Qiang; ZHAO Shen-Jie; LUO Chen; ZHAO Yu-Bin

    2012-01-01

    This paper illustrates the design and simulation of a unique 500 MHz single-cell superconducting radio frequency cavity with a fluted beam pipe and a coaxial-type fundamental power coupler.The simulation results show that the cavity has a high r/Q value,a low peak surface field and a large beam aperture,so it can be a candidate cavity for high current accelerators.With the help of a fluted beam tube,almost all the higher order modes can propagate out of the cavity,especially the first two dipole modes,TE111 and TM110,and the first higher monopole mode,TM011.The external quality factor of the coaxial fundamental power coupler is optimized to 1.2× 105,which will be useful when it is applied in the light source storage ring.

  4. Design of normal conducting 704 MHz and 2.1 GHz cavities for LEReC Linac

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Belomestnykh, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stony Brook Univ., NY (United States); Ben-Zvi, I. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stony Brook Univ., NY (United States); Brutus, J. C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Fedotov, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); McIntyre, G. [Brookhaven National Lab. (BNL), Upton, NY (United States); Smith, K. [Brookhaven National Lab. (BNL), Upton, NY (United States); Tuozzolo, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Veshcherevich, V. [Cornell Univ., Ithaca, NY (United States); Wu, Q. [Brookhaven National Lab. (BNL), Upton, NY (United States); Xu, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Zaltsman, A. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-05-03

    To improve RHIC luminosity for heavy ion beam energies below 10 GeV/nucleon, the Low Energy RHIC electron Cooler (LEReC) is currently under development at BNL. Two normal conducting cavities, a single cell 704 MHz cavity and a 3 cell 2.1 GHz third harmonic cavity, will be used in LEReC for energy spread correction. In this paper we report the design of these two cavities.

  5. Photonic crystal waveguide cavity with waist design for efficient trapping and detection of nanoparticles.

    Science.gov (United States)

    Lin, Pin-Tso; Lu, Tsan-Wen; Lee, Po-Tsung

    2014-03-24

    For manipulating nanometric particles, we propose a photonic crystal waveguide cavity design with a waist structure to enhance resonance characteristic of the cavity. For trapping a polystyrene particle of 50 nm radius on the lateral side of the waist, the optical force can reach 2308 pN/W with 24.7% signal transmission. Threshold power of only 0.32 mW is required for stable trapping. The total length of the device is relatively short with only ten photonic crystal periods, and the trapping can occur precisely and only at the waist. The designed cavity can also provide particle detection and surrounding medium sensing using the transmission spectrum with narrow linewidth. The simulated figure of merit of 110.6 is relatively high compared with those obtained from most plasmonic structures for sensing application. We anticipate this design with features of compact, efficient, and versatile in functionality will be beneficial for developing lab-on-chip in the future.

  6. Large Deflections of Elastic Rectangular Plates

    Science.gov (United States)

    Razdolsky, A. G.

    2015-11-01

    It is known that elastic large deflections of thin plates are governed by von Karman nonlinear equations. The analytical solution of these equations in the general case is unfeasible. Samuel Levy, in 1942, showed that large deflections of the rectangular plate can be expressed as a double series of sine-shaped harmonics (deflection harmonics). However, this method gave no way of creating the computer algorithm of solving the problem. The stress function expression taken in the Levy's method must be revised to find the approach that takes into account of all possible products of deflection coefficients. The algorithm of solving the problem for the rectangular plate with an arbitrary aspect ratio under the action of the lateral distributed load is reported in this paper. The approximation of the plate deflection is taken in the form of double series proposed by Samuel Levy. However, the expression for the stress function is presented in the form that incorporates products of deflection coefficients in the explicit form in distinction to the Levy's expression. The number of harmonics in the deflection expression may be arbitrary. The algorithm provides composing the system of governing cubic equations, which includes the deflection coefficients in the explicit form. Solving the equation system is based on using the principle of minimum potential energy. A method of the gradient descent is applied to find the equilibrium state of the plate as the minimum point of the potential energy. A computer program is developed on the basis of the present algorithm. Numerical examples carried out for the plate model with 16 deflection harmonics illustrate the potentialities of the program. The results of solving the examples are presented in the graphical form for the plates with a different aspect ratio and may be used under designing thin-walled elements of airplane and ship structures.

  7. Cavity Design, Fabrication and Commission Performance of a 750MHz, 4-rod Separator for CEBAF 4-Hall Beam Delivery System

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Haipeng [Jefferson Lab, Newport News, VA; Cheng, Guangfeng [Jefferson Lab, Newport News, VA; Turlington, Larry T. [Jefferson Lab, Newport News, VA; Wissmann, Mark J. [Jefferson Lab, Newport News, VA

    2015-09-01

    A short version of the original CEBAF normal conducting 4-rod separator cavity has been developed into a 750MHz one * since the concept of simultaneous 4-hall operation for CEBAF is introduced **. This work has been advanced further based on the EM design optimization, bench measurement and by conducting RF-thermal coupled simulation using CST and ANSYS to confirm the cavity tuning and thermal performance. The cavity fabrication used matured technology like copper plating and machining. The cavity flanges, couplers, tuners and cooling channels adopted consistent/compatible hardware with the existing 500MHz cavities. The electromagnetic and thermal design simulations have greatly reduced the prototyping and bench tuning time of the first prototype. Four production cavities have reached a typical 1.94MV kick voltage or 3.0kW wall loss on each cavity after a minor multipactoring or no processing, 7.5% overhead power than the design specification.

  8. Design and experiments for the waveguide to coaxial cable adapter of a cavity beam position monitor

    Institute of Scientific and Technical Information of China (English)

    LI Xiang; ZHENG Shu-Xin

    2011-01-01

    The waveguide to coaxial cable adapter is very important to the cavity beam position monitor(CBPM)because it determines how much of the energy in the cavity could be coupled outside.In this paper,the waveguide to coaxial cable adapter of a CBPM is designed and experiments are conducted.The curve shapes of experiments and simulations are very similar and the difference in reflection is less than 0.1.This progress provides a reliable method for designing the adapter.

  9. A HIGH POWER RF COUPLER DESIGN FOR MUON COOLING RF CAVITIES.

    Energy Technology Data Exchange (ETDEWEB)

    CORLETT,J.; LI,DERUN; RIMMER,R.; HOLTKAMP,N.; MORETTI,A.; KIRK,H.G.

    1999-03-29

    We present a high power RF coupler design for an interleaved {pi}/2 805 MHz standing wave accelerating structure proposed for an muon cooling experiment at FNAL. The coupler, in its simplest form, is a rectangular waveguide directly connected to an accelerating Cell through an open slot on the cavity side-wall or end-plates. Two of such couplers are needed to feed the interleaved cavities. Current high power RF test requires the coupler to be at critical coupling. Numerical simulations on the coupler designs using MAFIA will be presented.

  10. Design of Chaotic Cavities with Curved Wave Diffractors for Enhanced Low-Frequency Operation

    CERN Document Server

    Arnaut, L R

    2014-01-01

    Some numerical calculations are presented on the dependence of the average mode count and average mode density of electromagnetic cavities on their specific geometric design, based on the generalized Weyl law. The analysis focuses on a chaotic quasi-cubic cavity furnished with curved wave diffractors placed on its interior surface. The focus is on a design that increases the mode density and Q at relatively low frequencies. The results are of interest in reducing the `lowest usable frequency' and increasing the maximum field strength inside mode-stirred reverberation chambers.

  11. Methodology for the structural design of single spoke accelerating cavities at Fermilab

    Science.gov (United States)

    Passarelli, Donato; Wands, Robert H.; Merio, Margherita; Ristori, Leonardo

    2016-10-01

    Fermilab is planning to upgrade its accelerator complex to deliver a more powerful and intense proton-beam for neutrino experiments. In the framework of the so-called Proton Improvement Plan-II (PIP-II), we are designing and developing a cryomodule containing superconducting accelerating cavities, the Single Spoke Resonators of type 1 (SSR1). In this paper, we present the sequence of analysis and calculations performed for the structural design of these cavities, using the rules of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC). The lack of an accepted procedure for addressing the design, fabrication, and inspection of such unique pressure vessels makes the task demanding and challenging every time. Several factors such as exotic materials, unqualified brazing procedures, limited nondestructive examination, and the general R&D nature of these early generations of cavity design, conspire to make it impractical to obtain full compliance with all ASME BPVC requirements. However, the presented approach allowed us to validate the design of this new generation of single spoke cavities with values of maximum allowable working pressure that exceeds the safety requirements. This set of rules could be used as a starting point for the structural design and development of similar objects.

  12. Design and performance of a new induction furnace for heat treatment of superconducting radiofrequency niobium cavities

    Energy Technology Data Exchange (ETDEWEB)

    Pashupati Dhakal, Gianluigi Ciovati, Wayne Rigby, John Wallace, Ganapati Rao Myneni

    2012-06-01

    Superconducting radio frequency (SRF) cavities made of high purity niobium (Nb) are the building blocks of many modern particle accelerators. The fabrication process includes several cycles of chemical and heat treatment at low ({approx}120 deg C) and high ({approx}800 deg C) temperatures. In this contribution, we describe the design and performance of an ultra-high-vacuum furnace which uses an induction heating system to heat treat SRF cavities. Cavities are heated by radiation from the Nb susceptor. By using an all-niobium hot zone, contamination of the Nb cavity by foreign elements during heat treatment is minimized and allows avoiding subsequent chemical etching. The furnace was operated up to 1400 deg C with a maximum pressure of {approx}1 x 10{sup -5} Torr and the maximum achievable temperature is estimated to be higher than 2000 deg C. Initial results on the performance of a single cell 1.5 GHz cavity made of ingot Nb heat treated at 1200 deg C using this new induction furnace and without subsequent chemical etching showed a reduction of the RF losses by a factor of {approx}2 compared to cavities made of fine-grain Nb which underwent standard chemical and heat treatments.

  13. Cryogenic test of double quarter wave crab cavity for the LHC High luminosity upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Alberty, L. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Belomestnykh, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stony Brook Univ., NY (United States); Ben-Zvi, I. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stony Brook Univ., NY (United States); Calaga, R. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Cullen, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Capatina, O. [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Hammons, L. [Brookhaven National Lab. (BNL), Upton, NY (United States); Li, Z. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Marques, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Skaritka, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Verdu-Andres, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Wu, Q. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-05-03

    A Proof-of-Principle (PoP) Double Quarter Wave Crab Cavity (DQWCC) was designed and fabricated for the Large Hadron Collider (LHC) luminosity upgrade. A vertical cryogenic test has been done at Brookhaven National Lab (BNL). The cavity achieved 4.5 MV deflecting voltage with a quality factor above 3×109. We report the test results of this design.

  14. Development of 400- to 450-MHz RFQ resonator-cavity mechanical designs

    Energy Technology Data Exchange (ETDEWEB)

    Hansborough, L.D.

    1982-01-01

    In the development of the radio-frequency quadrupole (RFQ) linac, the resonator cavity's mechanical design may be a challenge similar in magnitude to that of the development of the accelerator structure itself. Experience with the all-copper 425-MHz RFQ proof-of-principle linac has demonstrated that the resonator cavity must be structurally stiff and easily tunable. This experience has led to development of copper-plated steel structures having vanes that may be moved within a cylinder for tuning. Design of a flexible vane-to-cylinder radio-frequency (rf) joint, the vane, and the cylinder has many constraints dictated by the small-diameter cavities in the 400-MHz-frequency region. Two types of flexible, mechanical vane-to-cylinder rf joints are being developed at Los Alamos: the C-seal and the rf clamp-joint.

  15. Design of an L-band normally conducting RF gun cavity for high peak and average RF power

    Science.gov (United States)

    Paramonov, V.; Philipp, S.; Rybakov, I.; Skassyrskaya, A.; Stephan, F.

    2017-05-01

    To provide high quality electron bunches for linear accelerators used in free electron lasers and particle colliders, RF gun cavities operate with extreme electric fields, resulting in a high pulsed RF power. The main L-band superconducting linacs of such facilities also require a long RF pulse length, resulting in a high average dissipated RF power in the gun cavity. The newly developed cavity based on the proven advantages of the existing DESY RF gun cavities, underwent significant changes. The shape of the cells is optimized to reduce the maximal surface electric field and RF loss power. Furthermore, the cavity is equipped with an RF probe to measure the field amplitude and phase. The elaborated cooling circuit design results in a lower temperature rise on the cavity RF surface and permits higher dissipated RF power. The paper presents the main solutions and results of the cavity design.

  16. Design of relief-cavity in closed-precision forging of gears

    Institute of Scientific and Technical Information of China (English)

    左斌; 王宝雨; 李智; 郑明男; 朱小星

    2015-01-01

    To reduce the difficulty of material filling into the top region of tooth in hot precision forging of gears using the alternative die designs, relief-cavity designs in different sizes were performed on the top of die tooth. The influences of the conventional process and relief-cavity designs on corner filling, workpiece stress, die stress, forming load and material utilization were examined. Finite element simulation for tooth forming, die stress and forming load using the four designs was performed. The material utilization was further considered, and the optimal design was determined. The tooth form and forming load in forging trials ensured the validity of FE simulation. Tooth accuracy was inspected by video measuring machine (VMM), which shows the hot forged accuracy achieves the level of rough machining of gear teeth. The effects of friction on mode of metal flow and strain distribution were also discussed.

  17. Vacuum System Design of Experimental Cavity for Study of Multipacting Effect with Nanosecond Resolution

    Institute of Scientific and Technical Information of China (English)

    YANG; Guang; WANG; Fei; YIN; Zhi-guo; JI; Bin; SONG; Guo-fang; XING; Jian-sheng

    2015-01-01

    To further optimize the nanosecond resolution multipacting effect experiment cavity,for checking 230MeV superconducting cyclotron RF system transmitter design,while based on overseas research for the residual gas discharge in the megahertz frequency range,at vacuum of the

  18. Rationale for designing cavity preparations in light of current knowledge and technology.

    Science.gov (United States)

    Welk, D A; Laswell, H R

    1976-04-01

    No restorative material presently available is as good as supported tooth structure and it is unlikely that a usable dental restorative material with the physical properties of enamel will ever be developed. The purpose of cavity preparation is to remove carious material and preserve sound tooth structure. Any additional removal of tooth structure is necessary for the convenience of the operator or because of limitations of the restorative materials. Presently available esthetic restorative systems for nonfunctional areas and selected anterior functional areas allow for designing cavity preparations where the only two considerations are removal of caries (and unsupported enamel) and placement of retentive features. The problem of cavity design for restoration of functional surfaces is not answered easily, but there is reasonable hope that in the near future an esthetic restorative material will be available that has the strength and other necessary properties to serve in functional areas. There should be no specific "ideal" design for cavity preparation. Each defect should be custom designed to remove the caries or defect and perform the additional steps necessitated by the limitations of the operator or restorative material. As advocated by Black in one of his later publications, it is necessary to make mouth-by-mouth and tooth-by-tooth judgements concerning the most desirable outline form to be obtained.

  19. Computer-aided design of the RF-cavity for a high-power S-band klystron

    Science.gov (United States)

    Kant, D.; Bandyopadhyay, A. K.; Pal, D.; Meena, R.; Nangru, S. C.; Joshi, L. M.

    2012-08-01

    This article describes the computer-aided design of the RF-cavity for a S-band klystron operating at 2856 MHz. State-of-the-art electromagnetic simulation tools SUPERFISH, CST Microwave studio, HFSS and MAGIC have been used for cavity design. After finalising the geometrical details of the cavity through simulation, it has been fabricated and characterised through cold testing. Detailed results of the computer-aided simulation and cold measurements are presented in this article.

  20. The Deflection Question

    Science.gov (United States)

    Greenberg, A. H.; Nesvold, E.; van Heerden, E.; Erasmus, N.; Marchis, F.

    2016-12-01

    On 15 February, 2013, a 15 m diameter asteroid entered the Earth's atmosphere over Russia. The resulting shockwave injured nearly 1500 people, and incurred 33 million (USD) in infrastructure damages. The Chelyabinsk meteor served as a forceful demonstration of the threat posed to Earth by the hundreds of potentially hazardous objects (PHOs) that pass near the Earth every year. Although no objects have yet been discovered on an impact course for Earth, an impact is virtually statistically guaranteed at some point in the future. While many impactor deflection technologies have been proposed, humanity has yet to demonstrate the ability to divert an impactor when one is found. Developing and testing any single proposed technology will require significant research time and funding. This leaves open an obvious question - towards which technologies should funding and research be directed, in order to maximize our preparedness for when an impactor is eventually found? To help answer this question, we have created a detailed framework for analyzing various deflection technologies and their effectiveness. Using an n-body integrator (REBOUND), we have simulated the attempted deflections of a population of Earth-impacting objects with a variety of velocity perturbations (∂Vs), and measured the effects that these perturbations had on impact probability. We then mapped the ∂Vs applied in the orbital simulations to the technologies capable of achieving those perturbations, and analyzed which set of technologies would be most effective at preventing a PHO from impacting the earth. As a final step, we used the results of these simulations to train a machine learning algorithm. This algorithm, combined with a simulated PHO population, can predict which technologies are most likely to be needed. The algorithm can also reveal which impactor observables (mass, spin, orbit, etc.) have the greatest effect on the choice of deflection technology. These results can be used as a tool to

  1. Design of horizontal test cryostat for testing two 650 MHz cavities: cryogenic considerations

    Science.gov (United States)

    Khare, P.; Gilankar, S.; Kush, P. K.; Lakshminarayanan, A.; Choubey, R.; Ghosh, R.; Jain, A.; Patel, H.; Gupta, P. D.; Hocker, A.; Ozelis, J. P.; Geynisman, M.; Reid, C.; Poloubotko, V.; Mitchell, D.; Peterson, T. J.; Nicol, T. H.

    2017-02-01

    Horizontal Test Cryostat has been designed for testing two 650 MHz "dressed" Superconducting Radio Frequency (SCRF) cavities in a single testing cycle at Raja Ramanna Centre for Advanced Technology, India (RRCAT) in collaboration with Fermi National Accelerator Laboratory, USA (FNAL). This cryostat will facilitate testing of two 5-cell 650 MHz SCRF cavities, in CW or pulsed regime, for upcoming High Intensity Superconducting Proton Accelerator projects at both countries. Two such HTS facilities are planned, one at RRCAT for Indian Spallation Neutron Source project (ISNS), which is on the horizon, and the other at FNAL, USA. A test cryostat, a part of horizontal test stand-2 (HTS-2) will be set up at RRCAT for Indian project. In order to maximize the utility of this facility, it can also be used to test two dressed 9-cell 1.3 GHz cavities and other similarly-sized devices. The facility assumes, as an input, the availability of liquid nitrogen at 80 K and liquid helium at 4.5 K and 2 K, with a refrigeration capacity of approximately 50 W at 2 K. Design work of cryostat has been completed and now procurement process is in progress. This paper discusses salient features of the cryostat. It also describes different design calculations and ANSYS analysis for cool down of few subsystems like cavity support system and liquid nitrogen cooled thermal radiation shield of horizontal test cryostat..

  2. Improved transoral surgical tool design by CT measurements of the oral cavity and pharynx.

    Science.gov (United States)

    Cox, Emily; Ghasemloonia, Ahmad; Nakoneshny, Steven C; Zareinia, Kourosh; Hudon, Mark; Lysack, John T; Sutherland, Garnette R; Dort, Joseph C

    2016-09-23

    The majority of head and neck cancers arise from the oral cavity and oropharynx. Many of these lesions will be amenable to surgical resection using transoral approaches including transoral robotic surgery (TORS). To develop and control TORS tools, precise dimensions of the oral cavity and pharynx are desirable. CT angiograms of 76 patients were analyzed. For the oral cavity, only the maximum length and width were measured, while for the pharynx, the width, length, and areas of the airway were all measured and the volume calculated. A prototype TORS tool was developed and tested based on the findings and dimensions. The design modification of the tool is in progress. The mean male oral cavity width and length were 93.3 ± 4.3 and 77.0 ± 7.2 mm, respectively, and the mean male pharyngeal width, length, area, and volume were 26.5 ± 7.2 mm, 16.2 ± 8.8 mm, 325 ± 149 mm(2), and 28,440 ± 14,100 mm(3), respectively, while the mean female oral cavity width and length were 84.5 ± 12.9 and 71.0 ± 6.3 mm, respectively, and the mean female pharyngeal width, length, area, and volume were 24.8 ± 5.6 mm, 13.7 ± 3.2 mm, 258 ± 98 mm(2), and 17,660 ± 7700 mm(3), respectively. The developed TORS tool was tested inside the oral cavity of an intubation mannequin. These data will also be used to develop an electronic no-go cone-shape tunnel to improve the safety of the surgical field. Reporting the oral cavity and pharyngeal dimensions is important for design of TORS tools and creating control zones for the workspace of the tool inside the oral cavity.

  3. Fractal apertures in waveguides, conducting screens and cavities analysis and design

    CERN Document Server

    Ghosh, Basudeb; Kartikeyan, M V

    2014-01-01

    This book deals with the design and analysis of fractal apertures in waveguides, conducting screens and cavities using numerical electromagnetics and field-solvers. The aim is to obtain design solutions with improved accuracy for a wide range of applications. To achieve this goal, a few diverse problems are considered. The book is organized with adequate space dedicated for the design and analysis of fractal apertures in waveguides, conducting screens, and cavities, microwave/millimeter wave applications followed by detailed case-study problems to infuse better insight and understanding of the subject. Finally, summaries and suggestions are given for future work. Fractal geometries were widely used in electromagnetics, specifically for antennas and frequency selective surfaces (FSS). The self-similarity of fractal geometry gives rise to a multiband response, whereas the  space-filling nature of the fractal geometries makes it an efficient element in antenna and FSS unit cell miniaturization. Until now, no e...

  4. Conceptual design of a high real-estate gradient cavity for a SRF ERL

    Science.gov (United States)

    Xu, Chen; Ben-Zvi, Ilan; Hao, Yue; Xin, Tianmu; Wang, Haipeng

    2017-10-01

    The term ;real-estate gradient; is used to describe the energy gain provided by an accelerating structure per actual length it takes in the accelerator. given that the length of the tunnel available for the accelerator is constrained, the real-estate gradient is an important measure of the efficiency of a given accelerator structure. When designing an accelerating cavity to be efficient in this sense, the unwanted Higher Order Mode (HOM) fields should be reduced by suitable HOM dampers. This is a particularly important consideration for high current operation. The additional RF components might take longitude space and reduce the total accelerating efficiency. We describe a new high efficiency 5-cell cavity with the dampers included. The total length of the cavity is reduced by 13% as compared to a more conventional design without compromising the cavity fundamental-mode performance. In addition, the HOM impedance is reduced for a higher Beam-Break-Up (BBU) threshold of operating current. In this paper, we consider an example, a possible application at the eRHIC Energy Recovery Linac (ERL).

  5. Deflections of Nanowires with Consideration of Surface Effects

    Institute of Scientific and Technical Information of China (English)

    LI He; YANG Zhou; ZHANG Yi-Min; WEN Bang-Chun

    2010-01-01

    @@ The elementary beam model is modified to include the surface effects and used to analyze the deflections of nanowires under different boundary conditions.The results show that compared to deflections of nanowires without consideration of surface effects,the surface effects can enlarge or reduce deflections of nanowires,and nanowire buckling occurs under certaJn conditions.This study might be helpful for design of nanowire-based nanoelectromechanical systems.

  6. Cuspal deflection and microleakage in premolar teeth restored with bulk-fill flowable resin-based composite base materials

    DEFF Research Database (Denmark)

    Moorthy, A; Hogg, C H; Dowling, A H;

    2012-01-01

    To assess the cuspal deflection and cervical microleakage of standardised Class II cavities incrementally filled with a dimethacrylate RBC or bulk-fill flowable RBC bases.......To assess the cuspal deflection and cervical microleakage of standardised Class II cavities incrementally filled with a dimethacrylate RBC or bulk-fill flowable RBC bases....

  7. Superconducting Cavity Cryomodule Designs for the Next Generation of CW Linacs: Challenges and Options

    Energy Technology Data Exchange (ETDEWEB)

    Nicol, Thomas [Fermilab; Orlov, Yuriy [Fermilab; Peterson, Thomas [Fermilab; Yakovlev, Vyacheslav [Fermilab

    2014-07-01

    The designs of nearly all superconducting RF (SRF) linacs over the last several years, with one notable exception being CEBAF at Jefferson Lab, have assumed pulsed beam operation with relatively low duty factors. These include the XFEL at DESY, the ILC, the original configuration for Project X at Fermilab, as well as several others. Recently proposed projects, on the other hand, including the LCLS-II at SLAC, the newly configured low and medium energy sections for Project X, and FRIB at Michigan State, to name a few, assume continuous wave or CW operation on quite a large scale with ambitious gradients and cavity performance requirements. This has implications in the cavity design as well as in many parts of the overall cryomodule due to higher dynamic heat loads in the cavities themselves and higher heat loads in the input and high-order-mode (HOM) couplers. Piping internal to the cryomodule, the effectiveness of thermal intercepts, the size of integrated heat exchangers, and many other aspects of the overall design are also affected. This paper will describe some of these design considerations as we move toward the next generation of accelerator projects.

  8. Impeller deflection and modal finite element analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, Nathan A.

    2013-10-01

    Deflections of an impeller due to centripetal forces are calculated using finite element analysis. The lateral, or out of plane, deflections are an important design consideration for this particular impeller because it incorporates an air bearing with critical gap tolerances. The target gap distance is approximately 10 microns at a rotational velocity of 2500 rpm. The centripetal forces acting on the impeller cause it deflect in a concave fashion, decreasing the initial gap distance as a function of radial position. This deflection is characterized for a previous and updated impeller design for comparative purposes. The impact of design options such as material selection, geometry dimensions, and operating rotational velocity are also explored, followed by a sensitivity study with these parameters bounded by specific design values. A modal analysis is also performed to calculate the impeller's natural frequencies which are desired to be avoided during operation. The finite element modeling techniques continue to be exercised by the impeller design team to address specific questions and evaluate conceptual designs, some of which are included in the Appendix.

  9. Design of a quasi-2D photonic crystal optomechanical cavity with tunable, large $x^2$-coupling

    CERN Document Server

    Kalaee, Mahmoud; Pfeifer, Hannes; Painter, Oskar

    2016-01-01

    We present the optical and mechanical design of a mechanically compliant quasi-two-dimensional photonic crystal cavity formed from thin-film silicon in which a pair of linear nanoscale slots are used to create two coupled high-$Q$ optical resonances. The optical cavity supermodes, whose frequencies are designed to lie in the $1500$~nm wavelength band, are shown to interact strongly with mechanical resonances of the structure whose frequencies range from a few MHz to a few GHz. Depending upon the symmetry of the mechanical modes and the symmetry of the slot sizes, we show that the optomechanical coupling between the optical supermodes can be either linear or quadratic in the mechanical displacement amplitude. Tuning of the nanoscale slot size is also shown to adjust the magnitude and sign of the cavity supermode splitting $2J$, enabling near-resonant motional scattering between the two optical supermodes and greatly enhancing the $x^2$-coupling strength. Specifically, for the fundamental flexural mode of the c...

  10. Design and calibration of the 34 GHz Yale microwave cavity experiment

    Energy Technology Data Exchange (ETDEWEB)

    Slocum, P.L., E-mail: penny.slocum@yale.edu [Department of Physics, Yale University, PO Box 208120, New Haven, CT 06520 (United States); Baker, O.K. [Department of Physics, Yale University, PO Box 208120, New Haven, CT 06520 (United States); Hirshfield, J.L. [Department of Physics, Yale University, PO Box 208120, New Haven, CT 06520 (United States); Omega-P, Inc., 291 Whitney Ave., Suite 401, New Haven, CT 06511 (United States); Jiang, Y.; Malagon, A.T.; Martin, A.J.; Shchelkunov, S. [Department of Physics, Yale University, PO Box 208120, New Haven, CT 06520 (United States); Szymkowiak, A. [Department of Physics, Yale University, PO Box 208120, New Haven, CT 06520 (United States); Department of Astronomy, Yale University, PO Box 208101, New Haven, CT 06520 (United States)

    2015-01-11

    Several proposed models of the cold dark matter in the universe include light neutral bosons with sub-eV masses. In many cases their detection hinges on their infrequent interactions with Standard Model photons at sub-eV energies. We describe the design and performance of an experiment to search for aberrations from the broadband noise power associated with a 5 K copper resonant cavity in the vicinity of 34 GHz (0.1 meV). The cavity, microwave receiver, and data reduction are described. Several configurations of the experiment are discussed in terms of their impact on the sensitivity of the search for axion-like particles and hidden sector photons.

  11. Design and Calibration of the 34 GHz Yale Microwave Cavity Experiment

    CERN Document Server

    Slocum, P L; Hirshfield, J L; Jiang, Y; Malagon, A T; Martin, A J; Shchelkunov, S; Szymkowiak, A

    2014-01-01

    Several proposed models of the cold dark matter in the universe include light neutral bosons with sub-eV masses. In many cases their detection hinges on their infrequent interactions with Standard Model photons at sub-eV energies. We describe the design and performance of an experiment to search for aberrations from the broadband noise power associated with a 5 K copper resonant cavity in the vicinity of 34 GHz (0.1 meV). The cavity, microwave receiver, and data reduction are described. Several configurations of the experiment are discussed in terms of their impact on the sensitivity of the search for axion-like particles and hidden sector photons.

  12. Experiments on Deflecting & Oscillating Waterjet

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    A new type jet,the oscillating & deflecting jet ,is put forward and its oscillating and deflecting characteristics are investigated.The nozzle of the self-oscillating & deflecting water jet consists of an upstream nozzle,a downstream nozzle,an oscillating chamber and two switches,It is experimentally shown that the deflective angle may reach 9.53 degeree,the generated pressure fluctuation is very regular and the jet can efficiently increase the ability for bradking and cutting by eliminating the water cushion effect associated with a continuous jet.

  13. Design and development progress of a LLRF control system for a 500 MHz superconducting cavity

    Science.gov (United States)

    Lee, Y. S.; Kim, H. W.; Song, H. S.; Lee, J. H.; Park, K. H.; Yu, I. H.; Chai, J. S.

    2012-07-01

    The LLRF (low-level radio-frequency) control system which regulates the amplitude and the phase of the accelerating voltage inside a RF cavity is essential to ensure the stable operation of charged particle accelerators. Recent advances in digital signal processors and data acquisition systems have allowed the LLRF control system to be implemented in digitally and have made it possible to meet the higher demands associated with the performance of LLRF control systems, such as stability, accuracy, etc. For this reason, many accelerator laboratories have completed or are completing the developments of digital LLRF control systems. The digital LLRF control system has advantages related with flexibility and fast reconfiguration. This paper describes the design of the FPGA (field programmable gate array) based LLRF control system and the status of development for this system. The proposed LLRF control system includes an analog front-end, a digital board (ADC (analog to digital converter), DAC (digital to analog converter), FPGA, etc.) and a RF & clock generation system. The control algorithms will be implemented by using the VHDL (VHSIC (very high speed integrated circuits) hardware description language), and the EPICS (experiment physics and industrial control system) will be ported to the host computer for the communication. In addition, the purpose of this system is to control a 500 MHz RF cavity, so the system will be applied to the superconducting cavity to be installed in the PLS storage ring, and its performance will be tested.

  14. Thermal design studies in superconducting rf cavities: Phonon peak and Kapitza conductance

    Directory of Open Access Journals (Sweden)

    A. Aizaz

    2010-09-01

    Full Text Available Thermal design studies of superconducting radio frequency (SRF cavities involve two thermal parameters, namely the temperature dependent thermal conductivity of Nb at low temperatures and the heat transfer coefficient at the Nb-He II interface, commonly known as the Kapitza conductance. During the fabrication process of the SRF cavities, Nb sheet is plastically deformed through a deep drawing process to obtain the desired shape. The effect of plastic deformation on low temperature thermal conductivity as well as Kapitza conductance has been studied experimentally. Strain induced during the plastic deformation process reduces the thermal conductivity in its phonon transmission regime (disappearance of phonon peak by 80%, which may explain the performance limitations of the defect-free SRF cavities during their high field operations. Low temperature annealing of the deformed Nb sample could not recover the phonon peak. However, moderate temperature annealing during the titanification process recovered the phonon peak in the thermal conductivity curve. Kapitza conductance measurements for the Nb-He II interface for various surface topologies have also been carried out before and after the annealing. These measurements reveal consistently increased Kapitza conductance after the annealing process was carried out in the two temperature regimes.

  15. Designing and Dosimetry of a Shield for Photon Fields of Radiation Therapy in Oral Cavity Cancer

    Science.gov (United States)

    Jabbari, Keyvan; Senobari, Somayeh; Roayaei, Mahnaz; Rostampour, Masoumeh

    2015-01-01

    The cancer of oral cavity is related to lesions of mucous membrane of tongue and gum that can be treated with radiation therapy. A lateral photon field can be used to treat this kind of tumor, which has a side-effect on normal tissue in the opposite side of the oral cavity. In this study the dosimetric effect of the various shields in oral cavity is evaluated. In this study, a special phantom similar to the structure of oral cavity with capability of film dosimetry was designed and constructed. The various shield slabs were made of five materials: Lead, Plexiglas, Acrylic resin, Silicon and Plaster. For irradiation, Cobalt 60 (60Co) and 6 MV photon beams were used. The film dosimetry before and after the shield was performed using GAFCHROMIC EBT2 films. The film before the shield measures the magnitude of backscattering radiation from the shield. The prescribed dose was 150 cGy. Results showed that 3 cm of the lead in both energies had the maximum absorption of radiation. The absorbed dose to opposite side of shield for 6 MV photon beams and 60Co were 21 and 32 cGy, respectively. The minimum attenuation on radiation was observed in silicon shield for which the dose of opposite side were 116 and 147 cGy for 6 MV and 60Co respectively. The maximum backscattered dose was measured 177 cGy and 219 cGy using 3 cm thickness of lead, which was quite considerable. The minimum backscattering where for acrylic resin 101 and 118 cGy for 6 MV and cobalt. In this study, it was concluded that the amount of backscattering for 3 cm Lead shield is quite considerable and increases the dose significantly. A composite layer of shield with 1–2 cm lead and 1 cm acrylic resin can have the protective effect and low backscattering radiation at the same time. PMID:26120570

  16. Design and modeling of a transistor vertical-cavity surface-emitting laser

    CERN Document Server

    Shi, Wei; Greenberg, Mark; Berggren, Jesper; Xiang, Yu; Hammar, Mattias; Lestrade, Michel; Li, Zhi-Qiang; Li, Z M Simon; Chrostowski, Lukas

    2011-01-01

    A multiple quantum well (MQW) transistor vertical-cavity surface-emitting laser (T-VCSEL) is designed and numerically modeled. The important physical models and parameters are discussed and validated by modeling a conventional VCSEL and comparing the results with the experiment. The quantum capture/escape process is simulated using the quantum-trap model and shows a significant effect on the electrical output of the T-VCSEL. The parameters extracted from the numerical simulation are imported into the analytic modeling to predict the frequency response and simulate the large-signal modulation up to 40 Gbps.

  17. A tunable waveguide-coupled cavity design for scalable interfaces to solid-state quantum emitters

    Directory of Open Access Journals (Sweden)

    Sara L. Mouradian

    2017-04-01

    Full Text Available Photonic nanocavities in diamond have emerged as useful structures for interfacing photons and embedded atomic color centers, such as the nitrogen vacancy center. Here, we present a hybrid nanocavity design that enables (i a loaded quality factor exceeding 50 000 (unloaded Q>106 with 75% of the enhanced emission collected into an underlying waveguide circuit, (ii MEMS-based cavity spectral tuning without straining the diamond, and (iii the use of a diamond waveguide with straight sidewalls to minimize surface defects and charge traps. This system addresses the need for scalable on-chip photonic interfaces to solid-state quantum emitters.

  18. Electric Deflection of Rotating Molecules

    CERN Document Server

    Gershnabel, E

    2010-01-01

    We provide a theory of the deflection of polar and non-polar rotating molecules by inhomogeneous static electric field. Rainbow-like features in the angular distribution of the scattered molecules are analyzed in detail. Furthermore, we demonstrate that one may efficiently control the deflection process with the help of short and strong femtosecond laser pulses. In particular the deflection process may by turned-off by a proper excitation, and the angular dispersion of the deflected molecules can be substantially reduced. We study the problem both classically and quantum mechanically, taking into account the effects of strong deflecting field on the molecular rotations. In both treatments we arrive at the same conclusions. The suggested control scheme paves the way for many applications involving molecular focusing, guiding, and trapping by inhomogeneous fields.

  19. Optical design and optimization of parabolic dish solar concentrator with a cavity hybrid receiver

    Science.gov (United States)

    Blázquez, R.; Carballo, J.; Silva, M.

    2016-05-01

    One of the main goals of the BIOSTIRLING-4SKA project, funded by the European Commission, is the development of a hybrid Dish-Stirling system based on a hybrid solar-gas receiver, which has been designed by the Swedish company Cleanergy. A ray tracing study, which is part of the design of this parabolic dish system, is presented in this paper. The study pursues the optimization of the concentrator and receiver cavity geometry according to the requirements of flux distribution on the receiver walls set by the designer of the hybrid receiver. The ray-tracing analysis has been performed with the open source software Tonatiuh, a ray-tracing tool specifically oriented to the modeling of solar concentrators.

  20. Design and Operational Experience of a Microwave Cavity Axion Detector for the 20-100 micro-eV Range

    CERN Document Server

    Kenany, S Al; Backes, K M; Brubaker, B M; Cahn, S B; Carosi, G; Gurevich, Y V; Kindel, W F; Lamoreaux, S K; Lehnert, K W; Lewis, S M; Malnou, M; Palken, D A; Rapidis, N M; Root, J R; Simanovskaia, M; Shokair, T M; Urdinaran, I; van Bibber, K A; Zhong, L

    2016-01-01

    We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the $5 - 25$ GHz range ($\\sim20-100\\: \\mu$eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently completed its first data production; it is the first microwave cavity axion search to deploy a Josephson parametric amplifier and a dilution refrigerator to achieve near-quantum limited performance.

  1. Design and operational experience of a microwave cavity axion detector for the 20 - 100 μeV range

    Science.gov (United States)

    Al Kenany, S.; Anil, M. A.; Backes, K. M.; Brubaker, B. M.; Cahn, S. B.; Carosi, G.; Gurevich, Y. V.; Kindel, W. F.; Lamoreaux, S. K.; Lehnert, K. W.; Lewis, S. M.; Malnou, M.; Palken, D. A.; Rapidis, N. M.; Root, J. R.; Simanovskaia, M.; Shokair, T. M.; Urdinaran, I.; van Bibber, K. A.; Zhong, L.

    2017-05-01

    We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the 5-25 GHz range (∼ 20 - 100 μeV) . The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently completed its first data production; it is the first microwave cavity axion search to deploy a Josephson parametric amplifier and a dilution refrigerator to achieve near-quantum limited performance.

  2. Impacts of Deflection Nose on Ballistic Trajectory Control Law

    Directory of Open Access Journals (Sweden)

    Bo Zhang

    2014-01-01

    Full Text Available The deflection of projectile nose is aimed at changing the motion of the projectile in flight with the theory of motion control and changing the exterior ballistics so as to change its range and increase its accuracy. The law of external ballistics with the deflectable nose is considered as the basis of the design of a flight control system and an important part in the process of projectile development. Based on the existing rigid external ballistic model, this paper establishes an external ballistic calculation model for deflectable nose projectile and further establishes the solving programs accordingly. Different angle of attack, velocity, coefficients of lift, resistance, and moment under the deflection can be obtained in this paper based on the previous experiments and emulation researches. In the end, the author pointed out the laws on the impaction of external ballistic trajectory by the deflection of nose of the missile.

  3. Optical Design of Dilute Nitride Quantum Wells Vertical Cavity Semiconductor Optical Amplifiers for Communication Systems

    Directory of Open Access Journals (Sweden)

    Faten A. Chaqmaqchee

    2016-04-01

    Full Text Available III-V semiconductors components such as Gallium Arsenic (GaAs, Indium Antimony (InSb, Aluminum Arsenic (AlAs and Indium Arsenic (InAs have high carrier mobilities and direct energy gaps. This is making them indispensable for today’s optoelectronic devices such as semiconductor lasers and optical amplifiers at 1.3 μm wavelength operation. In fact, these elements are led to the invention of the Gallium Indium Nitride Arsenic (GaInNAs, where the lattice is matched to GaAs for such applications. This article is aimed to design dilute nitride GaInNAs quantum wells (QWs enclosed between top and bottom of Aluminum (Gallium Arsenic Al(GaAs distributed bragg mirrors (DBRs using MATLAB® program. Vertical cavity semiconductor optical amplifiers (VCSOAs structures are based on Fabry Perot (FP method to design optical gain and bandwidth gain to be operated in reflection and transmission modes. The optical model gives access to the contact layer of epitaxial structure and the reflectivity for successive radiative modes, their lasing thresholds, emission wavelengths and optical field distributions in the laser cavity.

  4. Design verification of large time constant thermal shields for optical reference cavities.

    Science.gov (United States)

    Zhang, J; Wu, W; Shi, X H; Zeng, X Y; Deng, K; Lu, Z H

    2016-02-01

    In order to achieve high frequency stability in ultra-stable lasers, the Fabry-Pérot reference cavities shall be put inside vacuum chambers with large thermal time constants to reduce the sensitivity to external temperature fluctuations. Currently, the determination of thermal time constants of vacuum chambers is based either on theoretical calculation or time-consuming experiments. The first method can only apply to simple system, while the second method will take a lot of time to try out different designs. To overcome these limitations, we present thermal time constant simulation using finite element analysis (FEA) based on complete vacuum chamber models and verify the results with measured time constants. We measure the thermal time constants using ultrastable laser systems and a frequency comb. The thermal expansion coefficients of optical reference cavities are precisely measured to reduce the measurement error of time constants. The simulation results and the experimental results agree very well. With this knowledge, we simulate several simplified design models using FEA to obtain larger vacuum thermal time constants at room temperature, taking into account vacuum pressure, shielding layers, and support structure. We adopt the Taguchi method for shielding layer optimization and demonstrate that layer material and layer number dominate the contributions to the thermal time constant, compared with layer thickness and layer spacing.

  5. RFTech report on cavity design, LLRF & HPRF systems and design integration, & costing

    CERN Document Server

    De Conto, J M; Zimmermann, F

    2013-01-01

    This report highlights results from the EuCARD WP4.3 RFTech network, which was active from April 2009 to July 2013. The objective of RFTech was bringing together RF experts from different laboratories and communities, e.g. proton & electron accelerators, or storage rings & linacs, to exchange ideas and to promote innovation on all aspects of RF technology. RFTech organized 4 primary annual workshops and the organized or co-organized several topical workshops or dedicated sessions in larger conferences, like MIXDES, ICAP 12 etc. The present document highlights the main topics covered during this networking activity. The RFTech activities related to superconducting RF infrastructures are described in the EuCARD report “European Infrastructures for R&D and Test of Superconducting Radio-Frequency Cavities and Cryo-modules” (Wolfgang Weingarten, ISBN 978-83-7207-952-7).

  6. Generation of Picosecond X-Ray Pulses in the ALS Using RF Orbit Deflection

    CERN Document Server

    Robin, David; Fischer, Peter; Heimann, Philip; Kim, Dong-Hyun; Kwiatkowski, Slawomir; Li, Derun; Sannibale, Fernando; Steier, Christoph; Wan, Weishi; Wittmer, Walter; Zholents, Alexander

    2005-01-01

    A scheme is studied for producing ps length pulses of x-ray radiation from the Advanced Light Source (ALS) using two RF deflecting cavities. The cavities create vertical displacements of electrons correlated with their longitudinal position in the bunch. The two cavities separated by 180 degrees of vertical phase advance. This allows the vertical kick from one cavity to be compensated by the vertical kick of the other. The location of the cavities corresponds to the end of one straight section and the beginning of the following straight section. Halfway between the cavities a bending magnet source is located. The radiation from the bend can be compressed to ~1 ps in duration.

  7. Design and Analysis of the Distributed Resistor-loading GPR Antenna with Reflected Cavity

    Directory of Open Access Journals (Sweden)

    Wu Bing-heng

    2015-10-01

    Full Text Available In this study, we investigated the use of a half-ellipse dipole with distributed resistor-loading. By improving the structure of the antenna arms and using distributed resistor-loading technology, the current reflection at the end of dipole is significantly reduced, the input impedance is improved, and the operation bandwidth is widened. We decreased the backward radiation of the antenna with a cubic metal-reflective cavity and also improved the ground penetration ability. The proposed antenna was simulated and designed with electromagnetic computing software; on the basis of the design results, we fabricated the antenna sample. Measurement results of the return loss and radiation characteristics of the proposed antenna confirm the validity of the simulation. We applied the proposed antenna in a GPR system as an underground target detection experiment; on the basis of the experimental results, we conclude that the antenna is able to meet the needs of GPR systems.

  8. DTL cavity design and beam dynamics for a TAC linear proton accelerator

    Science.gov (United States)

    Caliskan, A.; Yılmaz, M.

    2012-02-01

    A 30 mA drift tube linac (DTL) accelerator has been designed using SUPERFISH code in the energy range of 3-55 MeV in the framework of the Turkish Accelerator Center (TAC) project. Optimization criteria in cavity design are effective shunt impedance (ZTT), transit-time factor and electrical breakdown limit. In geometrical optimization we have aimed to increase the energy gain in each RF gap of the DTL cells by maximizing the effective shunt impedance (ZTT) and the transit-time factor. Beam dynamics studies of the DTL accelerator have been performed using beam dynamics simulation codes of PATH and PARMILA. The results of both codes have been compared. In the beam dynamical studies, the rms values of beam emittance have been taken into account and a low emittance growth in both x and y directions has been attempted.

  9. DTL cavity design and beam dynamics for a TAC linear proton accelerator

    Institute of Scientific and Technical Information of China (English)

    A. Caliskan; M. Yi1maz

    2012-01-01

    A 30 mA drift tube linac (DTL) accelerator has been designed using SUPERFISH code in the energy range of 3-55 MeV in the framework of the Turkish Accelerator Center (TAC) project.Optimization criteria in cavity design are effective shunt impedance (ZTT),transit-time factor and electrical breakdown limit.In geometrical optimization we have aimed to increase the energy gain in each RF gap of the DTL cells by maximizing the effective shunt impedance (ZTT) and the transit-time factor.Beam dynamics studies of the DTL accelerator have been performed using beam dynamics simulation codes of PATH and PARMILA.The results of both codes have been compared.In the beam dynamical studies,the rms values of beam emittance have been taken into account and a low emittance growth in both x and y directions has been attempted.

  10. Flow channel design of a multi-cavity mold by filling simulation for thermosets. Netsu kokasei jushi ryudo kaiseki ni yoru cavity tasuko tori kanagata no ryuro sekkei

    Energy Technology Data Exchange (ETDEWEB)

    Saeki, J. (Hitachi Ltd., Tokyo (Japan)); Kaneda, A. (Hitachi Chemical Co. Ltd., Tokyo (Japan))

    1990-08-25

    A study was made on the flow channel design of a multi-cavity mold by filling simulation for thermosets. A practical analytic method was developed for the calculation of pressure losses at various locations in the channel following the estimation of viscosity change in the thermosets in the mold with optional shape. The runner and gate are designed for equal flow distribution to each cavity, and a newly developed model and a conventional type model were trially made for various evaluation using the conditions set at the time of designing. Ideal filling was achieved with the newly developed type model, and the design method of the type was confirmed to be reasonable. Characteristic values were studied which can be considered to give effect on the deformation of gold wires and void formation in molded devices. The effects on the prevention of gold wire deformation, decrease in void formation, and widening formation margin were confirmed. By the developed mold designing method, less diameter gold wire may be used without decreasing the quality of the package. 10 refs., 11 figs., 5 tabs.

  11. 3D nanoimprint for NIR Fabry-Pérot filter arrays: fabrication, characterization and comparison of different cavity designs

    Science.gov (United States)

    Nguyen, Duc Toan; Ababtain, Muath; Memon, Imran; Ullah, Anayat; Istock, André; Woidt, Carsten; Xie, Weichang; Lehmann, Peter; Hillmer, Hartmut

    2016-11-01

    We report on the fabrication of miniaturized NIR spectrometers based on arrays of multiple Fabry-Pérot (FP) filters. The various cavities of different height are fabricated via a single patterning step using high resolution 3D nanoimprint technology. Today, low-cost patterning of extended cavity heights for NIR filters using the conventional spin-coated nanoimprint methodology is not available because of insufficient coating layers and low mobility of the resist materials to fill extended cavity structures. Our investigation focuses on reducing the technological effort for fabrication of homogeneous extended cavities. We study alternative cavity designs, including a new resist and apply large-area 3D nanoimprint based on hybrid mold and UV Substrate Conformal Imprint Lithography (UV-SCIL) to overcome these limitations. We compare three different solutions, i.e. (1) applying multiple spin coating of the resist to obtain thicker initial resist layers, (2) introducing a hybrid cavity (combination of a thin oxide layer and the organic cavity) to compensate the height differences, and (3) optimizing the imprint process with a novel resist material. The imprint results based on these methods demonstrate the implementation of NIR FP filters with high transmission intensity (best single filter transmission >90 %) and small line widths (<5 nm in full width at half maximum).

  12. 3D nanoimprint for NIR Fabry-Pérot filter arrays: fabrication, characterization and comparison of different cavity designs

    Directory of Open Access Journals (Sweden)

    Duc Toan Nguyen

    2016-02-01

    Full Text Available Abstract We report on the fabrication of miniaturized NIR spectrometers based on arrays of multiple Fabry-Pérot (FP filters. The various cavities of different height are fabricated via a single patterning step using high resolution 3D nanoimprint technology. Today, low-cost patterning of extended cavity heights for NIR filters using the conventional spin-coated nanoimprint methodology is not available because of insufficient coating layers and low mobility of the resist materials to fill extended cavity structures. Our investigation focuses on reducing the technological effort for fabrication of homogeneous extended cavities. We study alternative cavity designs, including a new resist and apply large-area 3D nanoimprint based on hybrid mold and UV Substrate Conformal Imprint Lithography (UV-SCIL to overcome these limitations. We compare three different solutions, i.e. (1 applying multiple spin coating of the resist to obtain thicker initial resist layers, (2 introducing a hybrid cavity (combination of a thin oxide layer and the organic cavity to compensate the height differences, and (3 optimizing the imprint process with a novel resist material. The imprint results based on these methods demonstrate the implementation of NIR FP filters with high transmission intensity (best single filter transmission >90 % and small line widths (<5 nm in full width at half maximum.

  13. Electromagnetic Design of RF Cavities for Accelerating Low-Energy Muons

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, Sergey S. [Los Alamos National Laboratory

    2012-05-14

    A high-gradient linear accelerator for accelerating low-energy muons and pions in a strong solenoidal magnetic field has been proposed for homeland defense and industrial applications. The acceleration starts immediately after collection of pions from a target in a solenoidal magnetic field and brings decay muons, which initially have kinetic energies mostly around 15-20 MeV, to 200 MeV over a distance of {approx}10 m. At this energy, both ionization cooling and further, more conventional acceleration of the muon beam become feasible. A normal-conducting linac with external-solenoid focusing can provide the required large beam acceptances. The linac consists of independently fed zero-mode (TM{sub 010}) RF cavities with wide beam apertures closed by thin conducting edge-cooled windows. Electromagnetic design of the cavity, including its RF coupler, tuning and vacuum elements, and field probes, has been developed with the CST MicroWave Studio, and is presented.

  14. Influence of cavity preparation design on fracture resistance of posterior Leucite-reinforced ceramic restorations.

    Science.gov (United States)

    Soares, Carlos Jose; Martins, Luis Roberto Marcondes; Fonseca, Rodrigo Borges; Correr-Sobrinho, Lourenco; Fernandes Neto, Alfredo Julio

    2006-06-01

    Controversy exists concerning the preferred cavity design for posterior ceramic restorations to improve their resistance to fracture under occlusal load. The aim of this study was to assess the resistance to fracture of leucite-reinforced ceramic restorations placed on molars with different cavity preparation designs. Ninety noncarious molars were selected, stored in 0.2% thymol solution, and divided into 9 groups (n = 10): IT, intact teeth; CsI, conservative inlay; ExI, extensive inlay; CsO/mb, conservative onlay with mesio-buccal cusp coverage; ExO/mb, entensive onlay with mesio-buccal cusp coverage; CsO/b, conservative onlay with buccal cusp coverage; ExO/b, entensive onlay with buccal cusp coverage; CsO/t, conservative onlay with total cusp coverage; ExO/t, extensive onlay with total cusp coverage. Teeth were restored with a Leucite-reinforced ceramic (Cergogold). The fracture resistance (N) was assessed under compressive load in a universal testing machine. The data were analyzed with 1-way and 2-way analyses of variance, followed by the Tukey HSD test (alpha = .05). Fracture modes were recorded, based on the degree of tooth structure and restoration damage. One-way analysis showed that intact teeth had the highest fracture resistance values. Two-way analyses showed no significant differences for the isthmus extention factor, but showed a significant difference for the preparation design type of fracture (P = .03), and also for the interaction between both factors (P = .013). The fracture mode observed in all groups tended to involve only restorations. Within the limitations of this study, it was observed that cuspal coverage does not increase fracture resistance of the posterior tooth-restoration complex restored with leucite-reinforced ceramics.

  15. Load Deflection Characteristics of Nickel Titanium Initial Archwires

    Directory of Open Access Journals (Sweden)

    Hossein Aghili

    2016-05-01

    Full Text Available Objectives: The aim of this study was to assess and compare the characteristics of commonly used initial archwires by their load deflection graphs.Materials and Methods: This study tested three wire designs namely copper nickel titanium (CNT, nickel titanium (NiTi, and multi-strand NiTi (MSNT archwires engaged in passive self-ligating (PSL brackets, active self-ligating (ASL brackets or conventional brackets. To evaluate the mechanical characteristics of the specimens, a three-point bending test was performed. The testing machine vertically applied force on the midpoint of the wire between the central incisor and canine teeth to obtain 2 and 4mm of deflection. The force level at maximum deflection and characteristics of plateau (the average plateau load and the plateau length were recorded. Two-way ANOVA and Tukey’s test were used at P <0.05 level of significance.Results: Force level at maximum deflection and plateau length were significantly affected by the amount of deflection. The type of archwires and brackets had significant effects on force level at maximum deflection, and plateau length. However, the bracket type had no significant effect on the average plateau force.Conclusion: With any type of brackets in deflections of 2 and 4mm, MSNT wire exerted the lowest while NiTi wire exerted the highest force level at maximum deflection and plateau phase. The force level at maximum deflection and the plateau length increased with raising the amount of primary deflection; however the average plateau force did not change significantly.

  16. Directed energy deflection laboratory measurements

    Science.gov (United States)

    Brashears, Travis; Lubin, Phillip; Hughes, Gary B.; Meinhold, Peter; Suen, Jonathan; Batliner, Payton; Motta, Caio; Griswold, Janelle; Kangas, Miikka; Johansson, Isbella; Alnawakhtha, Yusuf; Prater, Kenyon; Lang, Alex; Madajian, Jonathan

    2015-09-01

    We report on laboratory studies of the effectiveness of directed energy planetary defense as a part of the DESTAR (Directed Energy System for Targeting of Asteroids and exploRation) program. DE-STAR [1][5][6] and DE-STARLITE [2][5][6] are directed energy "stand-off" and "stand-on" programs, respectively. These systems consist of a modular array of kilowatt-class lasers powered by photovoltaics, and are capable of heating a spot on the surface of an asteroid to the point of vaporization. Mass ejection, as a plume of evaporated material, creates a reactionary thrust capable of diverting the asteroid's orbit. In a series of papers, we have developed a theoretical basis and described numerical simulations for determining the thrust produced by material evaporating from the surface of an asteroid [1][2][3][4][5][6]. In the DE-STAR concept, the asteroid itself is used as the deflection "propellant". This study presents results of experiments designed to measure the thrust created by evaporation from a laser directed energy spot. We constructed a vacuum chamber to simulate space conditions, and installed a torsion balance that holds an "asteroid" sample. The sample is illuminated with a fiber array laser with flux levels up to 60 MW/m2 which allows us to simulate a mission level flux but on a small scale. We use a separate laser as well as a position sensitive centroid detector to readout the angular motion of the torsion balance and can thus determine the thrust. We compare the measured thrust to the models. Our theoretical models indicate a coupling coefficient well in excess of 100 μN/Woptical, though we assume a more conservative value of 80 μN/Woptical and then degrade this with an optical "encircled energy" efficiency of 0.75 to 60 μN/Woptical in our deflection modeling. Our measurements discussed here yield about 45 μN/Wabsorbed as a reasonable lower limit to the thrust per optical watt absorbed.

  17. HOM damping and multipacting analysis of the quarter-wave crab cavity

    Energy Technology Data Exchange (ETDEWEB)

    Wu Q.; Belomestnykh, S.; Ben-Zvi, I.; Calaga, R.

    2012-05-20

    The quarter-wave crab cavity design has been analyzed further to accommodate LHC requirements. The goal for the design is to provide strong deflecting voltage to the proton bunches at the IP, while keeping the effective length as short as possible. We will evaluate the higher order mode damping with two or four magnetic coupling dampers installed in different configuration. In this paper, we also show possible multipacting locations which are simulated by 2D and 3D codes.

  18. Design of cavity-enhanced absorption cell for reducing transit-time broadening.

    Science.gov (United States)

    Abe, Masashi; Iwakuni, Kana; Okubo, Sho; Sasada, Hiroyuki

    2014-09-15

    To reduce the linewidth of Lamb dips, we introduce a cavity-enhanced absorption cell (CEAC) coupled with a Gaussian beam with a 1.9-mm 1/e(2) radius at the beam waist for the reduction of transit-time broadening. We state that transit-time broadening depends only on the beam radius at the beam waist. This fact is useful for the design of the CEAC, and a pair of concave and convex mirrors is thereby employed. We have carried out sub-Doppler resolution spectroscopy of the ν(3) band of CH(4) and the ν(1) band of CH(3)D using a difference-frequency-generation source and the CEAC, and the recorded Lamb dips narrow to 80 kHz (HWHM).

  19. Conceptual Design Of An Ideal Variable Coupler For Superconducting Radiofrequency 1.3GHz Cavities

    CERN Document Server

    Xu, Chen

    2014-01-01

    Inspired by the development of over-moded RF component as an undulator, we explored another over-moded structure that could serve the variable coupling for SRF purpose. This application is to fulfill variation of S11 from 0 to -20db with CW power of 7 KW. The static heat loss in the coupler is trivial from calculation. An advantage of this coupler is that the thermal isolation between the 2K and 300K section is considerable by vacuum separation. Within this coupler, only a single propagation mode is allowed at each section, and thus, the fact that no energy is converted to high order mode bring almost full match without loss. The analytical and numerical calculation for a two window variable coupler is designed and optimized. A RF power variation is illustrated in the scattering matrix and coupling to cavity is also discussed.

  20. A Tunable Waveguide-Coupled Cavity Design for Efficient Spin-Photon Interfaces in Photonic Integrated Circuits

    CERN Document Server

    Mouradian, Sara

    2016-01-01

    A solid state emitter coupled to a photonic crystal cavity exhibits increased photon emission into a single frequency mode. However, current designs for photonic crystal cavities coupled to quantum emitters have three main problems: emitters are placed near surfaces that can degrade their optical properties, the cavity fluorescence cannot be collected into a single useful mode for further routing, and post-fabrication tuning is not currently possible in a stable and reversible manner for each node individually. In this paper, we introduce a hybrid cavity design with minimal fabrication of the host material that keeps the emitter $\\geq100\\,$nm from all surfaces. This cavity has an unloaded quality factor ($Q$) larger than $1\\times10^6$ and a loaded $Q$ of $5.5\\times10^4$ with more than 75% of the emission coupled directly into an underlying photonic integrated circuit built from a convenient material that provides low loss waveguides. Finally this design can be actively and reversibly tuned onto resonance with...

  1. 交指型腔体滤波器设计%Interdigital cavity filter design

    Institute of Scientific and Technical Information of China (English)

    陈丽艳; 刘甫坤; 单家方; 贾华; 李军

    2011-01-01

    The lower hybrid current drive system will be interferenced by jamming signal in the EAST experiment site, so a interdigital cav. ity filter with passband centered at 2.45GHz is designed to repress the jamming signal.This paper gives the particular description of a theoretical analysis and practical design for interdigital cavity filter, and the filter is simulated by HFSS-software which greatly improves the efficiency and accuracy of the design.%为抑制 EAST 装置现场的电磁信号对低杂波系统运行的干扰,设计了一个交指型腔体滤波器,其中心频率为 2.45GHz,带宽为 O.245GHz.介绍了交指型腔体滤波器的设计思路和方法,利用高频电磁仿真软件 HFSS仿真提高了设计效率和精度.

  2. Creating geometrically robust designs for highly sensitive problems using topology optimization: Acoustic cavity design

    DEFF Research Database (Denmark)

    Christiansen, Rasmus E.; Lazarov, Boyan S.; Jensen, Jakob S.;

    2015-01-01

    and limitations are discussed. In addition, a known explicit penalization approach is considered for comparison. For near-uniform spatial variations it is shown that highly robust designs can be obtained using the double filter approach. It is finally demonstrated that taking non-uniform variations into account...

  3. A self-designed instrument to evaluate cavosurface angle for class I amalgam cavity preparation: A learning aid.

    Science.gov (United States)

    Arora, Ankit; Acharya, Shashi Rashmi; Ballal, Vasudev; Sharma, Padmaja

    2012-07-01

    Fighting the controversies, amalgam, as a posterior restorative material has survived till date. The fate of amalgam restoration is determined by geometry of the cavity preparation and cavosurface angle is one integral part of the cavity, which decides the marginal characteristics of the restoration and health of the tooth. Low edge strength of amalgam highlights the importance of cavosurface angle. However, at the same time conservation of the tooth also should be considered. This article presents a self-designed instrument to evaluate and obtain a cavosurface angle close to 110°. The design of the instrument also helps in evaluating parameters, such as depth of the cavity, undercut angle, and allows finishing of the buccal or lingual walls.

  4. Benchmarking Asteroid-Deflection Experiment

    Science.gov (United States)

    Remington, Tane; Bruck Syal, Megan; Owen, John Michael; Miller, Paul L.

    2016-10-01

    An asteroid impacting Earth could have devastating consequences. In preparation to deflect or disrupt one before it reaches Earth, it is imperative to have modeling capabilities that adequately simulate the deflection actions. Code validation is key to ensuring full confidence in simulation results used in an asteroid-mitigation plan. We are benchmarking well-known impact experiments using Spheral, an adaptive smoothed-particle hydrodynamics code, to validate our modeling of asteroid deflection. We describe our simulation results, compare them with experimental data, and discuss what we have learned from our work. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. LLNL-ABS-695540

  5. RF cavity design exploiting a new derivative-free trust region optimization approach

    Directory of Open Access Journals (Sweden)

    Abdel-Karim S.O. Hassan

    2015-11-01

    Full Text Available In this article, a novel derivative-free (DF surrogate-based trust region optimization approach is proposed. In the proposed approach, quadratic surrogate models are constructed and successively updated. The generated surrogate model is then optimized instead of the underlined objective function over trust regions. Truncated conjugate gradients are employed to find the optimal point within each trust region. The approach constructs the initial quadratic surrogate model using few data points of order O(n, where n is the number of design variables. The proposed approach adopts weighted least squares fitting for updating the surrogate model instead of interpolation which is commonly used in DF optimization. This makes the approach more suitable for stochastic optimization and for functions subject to numerical error. The weights are assigned to give more emphasis to points close to the current center point. The accuracy and efficiency of the proposed approach are demonstrated by applying it to a set of classical bench-mark test problems. It is also employed to find the optimal design of RF cavity linear accelerator with a comparison analysis with a recent optimization technique.

  6. Interdigital Cavity Filter Design%交指型腔体滤波器设计

    Institute of Scientific and Technical Information of China (English)

    陈丽艳; 刘甫坤; 单家方

    2011-01-01

    It deals with the design of interdigital cavity filter with passband used in 2.45 GHz Lower Hybrid Current Drive system. The parameters of filter is obtained in according with the exact design theory of the interdigital bandpass filter. The filter is simulated by HFSS - software, which greatly improves the efficiency and accuracy . The simulation result shows good agreement with theoretical result, which proves the method is valid.%设计了一个用于2.45 GHz低杂波电流驱动系统的交指型腔体带通滤波器.根据交指型带通滤波器的准确设计理论,获得滤波器的结构尺寸.利用HFSS软件仿真,提高了设计效率和精度,最终仿真结果和理论结果一致,证明了设计方法的可行性.

  7. Geometric formula for prism deflection

    Indian Academy of Sciences (India)

    Apoorva G Wagh; Veer Chand Rakhecha

    2004-08-01

    While studying neutron deflections produced by a magnetic prism, we have stumbled upon a simple `geometric' formula. For a prism of refractive index close to unity, the deflection simply equals the product of the refractive power − 1 and the base-to-height ratio of the prism, regardless of the apex angle. The base and height of the prism are measured respectively along and perpendicular to the direction of beam propagation within the prism. The geometric formula greatly simplifies the optimisation of prism parameters to suit any specific experiment.

  8. Relativistic Stern-Gerlach Deflection

    CERN Document Server

    Talman, Richard

    2016-01-01

    Modern advances in polarized beam control should make it possible to accurately measure Stern-Gerlach (S-G) deflection of relativistic beams. Toward this end a relativistically covariant S-G formalism is developed that respects the opposite behavior under inversion of electric and magnetic fields. Not at all radical, or even new, this introduces a distinction between electric and magnetic fields that is not otherwise present in pure Maxwell theory. Experimental configurations (mainly using polarized electron beams passing through magnetic or electric quadrupoles) are described. Electron beam preparation and experimental methods needed to detect the extremely small deflections are discussed.

  9. Design and Development of an Octopus Thermometric system for the 704 MHZ Single-Cell SPL Cavity at CERN

    CERN Document Server

    Liao, K; Brunner, O; Ciapala, E; Glenat, D; Weingarten, W

    2012-01-01

    The octopus thermometric system is designed for the 704 MHz superconducting proton linac (SPL) cavity to detect hot spots and X-rays caused by normal conducting defects and the impact of emission electrons. This system features an octopus body and tentacle structure for good contact with the cavity and easy assembly, a multiplexing circuit with integrated microprocessor for efficient readout and a high density temperature sensor arrangement in order to complete a high resolution temperature and X-ray map. The first prototype is being manufactured and investigations are undergoing for further development.

  10. Design of a three-dimensional photonic band gap cavity in a diamondlike inverse woodpile photonic crystal

    Science.gov (United States)

    Woldering, Léon A.; Mosk, Allard P.; Vos, Willem L.

    2014-09-01

    We theoretically investigate the design of cavities in a three-dimensional (3D) inverse woodpile photonic crystal. This class of cubic diamondlike crystals has a very broad photonic band gap and consists of two perpendicular arrays of pores with a rectangular structure. The point defect that acts as a cavity is centered on the intersection of two intersecting perpendicular pores with a radius that differs from the ones in the bulk of the crystal. We have performed supercell band structure calculations with up to 5×5×5 unit cells. We find that up to five isolated and dispersionless bands appear within the 3D photonic band gap. For each isolated band, the electric-field energy is localized in a volume centered on the point defect, hence the point defect acts as a 3D photonic band gap cavity. The mode volume of the cavities resonances is as small as 0.8 λ3 (resonance wavelength cubed), indicating a strong confinement of the light. By varying the radius of the defect pores we found that only donorlike resonances appear for smaller defect radius, whereas no acceptorlike resonances appear for greater defect radius. From a 3D plot of the distribution of the electric-field energy density we conclude that peaks of energy are found in sharp edges situated at the point defect, similar to how electrons collect at such features. This is different from what is observed for cavities in noninverted woodpile structures. Since inverse woodpile crystals can be fabricated from silicon by CMOS-compatible means, we project that single cavities and even cavity arrays can be realized, for wavelength ranges compatible with telecommunication windows in the near infrared.

  11. Design of an efficient terahertz source using triply resonant nonlinear photonic crystal cavities.

    Science.gov (United States)

    Burgess, Ian B; Zhang, Yinan; McCutcheon, Murray W; Rodriguez, Alejandro W; Bravo-Abad, Jorge; Johnson, Steven G; Loncar, Marko

    2009-10-26

    We propose a scheme for efficient cavity-enhanced nonlinear THz generation via difference-frequency generation (DFG) processes using a triply resonant system based on photonic crystal cavities. We show that high nonlinear overlap can be achieved by coupling a THz cavity to a doubly-resonant, dual-polarization near-infrared (e.g. telecom band) photonic-crystal nanobeam cavity, allowing the mixing of three mutually orthogonal fundamental cavity modes through a chi((2)) nonlinearity. We demonstrate through coupled-mode theory that complete depletion of the pump frequency - i.e., quantum-limited conversion - is possible. We show that the output power at the point of optimal total conversion efficiency is adjustable by varying the mode quality (Q) factors.

  12. Design of N-type feedthrough for HOM coupler for cERL injector cavity

    Science.gov (United States)

    Watanabe, K.; Noguchi, S.; Kako, E.; Shishido, T.

    2014-01-01

    The injector cryomodule for the compact energy recovery linac (cERL) is under development at KEK. The cryomodule with 3L-band 2-cell cavities was built in June 2012. A prototype 2-cell cavity and three other 2-cell cavities with five higher-order-mode (HOM) couplers for actual operation were fabricated in May 2011. The vertical tests of these cavities were carried out after standard surface preparation at the KEK Superconducting accelerator Test Facility (KEK-STF) from October 2010 to March 2012. Radio-frequency feedthroughs with high thermal conductivity for the HOM coupler were also developed to achieve 12.5 MV/m CW operation in the cryomodule. A Kyocera NR-type connector was modified to connect to this target. The results of vertical tests of the 2-cell cavities to measure their feedthrough performance will be reported in this paper.

  13. Design and High Power Testing of 52.809 MHz RF Cavities for Slip Stacking in the Fermilab Recycler

    CERN Document Server

    Madrak, R

    2014-01-01

    For NOvA and future experiments requiring high intensity proton beams, Fermilab is in the process of upgrading the existing accelerator complex for increased proton production. One such improvement is to reduce the Main Injector cycle time, by performing slip stacking, previously done in the Main Injector, in the now repurposed Recycler Ring. Recycler slip stacking requires two new RF cavities operating at slightly different frequencies (df = 1260Hz). These are copper, coaxial, quarter wave cavities with R/Q =13 ohms. They operate at a peak gap voltage of 150 kV with 150 kW peak drive power (60% duty factor), and are resonant at 52.809 MHz with a 10 kHz tuning range. Two have been completed and installed. The design, high power test results, and status of the cavities are presented.

  14. Fracture strength of the remaining dental structure after different cavity preparation designs.

    Science.gov (United States)

    Teixeira, Evisabel Siqueira Simões; Rizzante, Fabio Antonio Piola; Ishikiriama, Sérgio Kiyoshi; Mondelli, José; Furuse, Adilson Yoshio; Mondelli, Rafael Francisco Lia; Bombonatti, Juliana Fraga Soares

    2016-01-01

    The aim of this in vitro study was to evaluate the loss of tooth structure after cavity preparation for direct (retentive) and indirect (nonretentive) restorations and its relationship to the fracture strength of the prepared tooth. Sound human third molars (60 maxillary and 60 mandibular) were randomly assigned into 12 groups (n = 10) according to the type of cavity preparation and the respective buccolingual width. Class II mesio-occlusodistal cavity preparations, for both indirect inlay and direct resin restorations, were prepared with standardized dimensions of one-half, one-third, or one-quarter of the occlusal intercuspal distance. Fracture resistance was lower and weight loss was greater for all nonretentive preparations. Greater losses in weight and fracture resistance occurred when the buccolingual width for both types of cavities increased, except for the weight loss of the one-quarter and one-third indirect cavity preparations in the mandibular molars, and the fracture resistance of the one-half and one-third direct cavity preparations in maxillary molars. Higher tooth structure loss and lower fracture strength were recorded after preparation of the inlay cavities.

  15. Conception design of helium ion FFAG accelerator with induction accelerating cavity

    Institute of Scientific and Technical Information of China (English)

    LUO Huan-Li; XU Yu-Cun; WANG Xiang-Qi; XU Hong-Liang

    2013-01-01

    In the recent decades of particle accelerator R&D area,the fixed field alternating gradient (FFAG) accelerator has become a highlight for some advantages of its higher beam intensity and lower cost,although there are still some technical challenges.In this paper,the FFAG accelerator is adopted to accelerate a helium ion beam on the one hand for the study of helium embrittlement on fusion reactor envelope material and on the other hand for promoting the conception research and design of the FFAG accelerator and exploring the possibility of developing high power FFAG accelerators.The conventional period focusing unit of the helium ion FFAG accelerator and threedimensional model of the large aperture combinatorial magnet by OPERA-TOSCA are given.For low energy and low revolution frequency,induction acceleration is proposed to replace conventional radio frequency (RF) acceleration for the helium ion FFAG accelerator,which avoids the potential breakdown of the acceleration field caused by the wake field and improves the acceleration repetition frequency to gain higher beam intensity.The main parameters and three-dimensional model of induction cavity are given.Two special constraint waveforms are proposed to refrain from particle accelerating time slip (AT) caused by accelerating voltage drop of flat top and energy deviation.The particle longitudinal motion in two waveforms is simulated.

  16. Design of a second cyclotron harmonic gyrotron oscillator with photonic band-gap cavity

    Energy Technology Data Exchange (ETDEWEB)

    Liu Gaofeng; Chen Xiaoan; Tang Changjian, E-mail: angelchen765@163.com [College of Physical Science and Technology of Sichuan University, Chengdu 610065 (China)

    2011-07-27

    A photonic band-gap cavity (PBGC) gyrotron with a frequency of about 98 GHz is designed. Theoretical analyses and numerical calculations are made for the PBGC operating at fundamental and second cyclotron harmonic with a TE{sub 34} waveguide mode to demonstrate the beam-wave interaction. The results show that mode competition is successfully eliminated in the PBGC using mode selectivity and choosing the appropriate operating parameters. As a result, the second harmonic PBGC gyrotron operating at TE{sub 34} mode achieves a higher output efficiency than that of the fundamental. It is also demonstrated that, in the case of the chosen parameters for TE{sub 34} waveguide mode, the use of PBG structure in the second harmonic gyrotron brings about not only a lower operating B-field but also a weaker mode competition. The results show that the high-order electromagnetic mode can be developed to interact with the high cyclotron harmonic using the selectivity of the PBGC, which gives an encouraging outlook for the development of high-harmonic gyrotrons.

  17. Systematic cavity design approach for a multi-frequency gyrotron for DEMO and study of its RF behavior

    Science.gov (United States)

    Kalaria, P. C.; Avramidis, K. A.; Franck, J.; Gantenbein, G.; Illy, S.; Pagonakis, I. Gr.; Thumm, M.; Jelonnek, J.

    2016-09-01

    High frequency (>230 GHz) megawatt-class gyrotrons are planned as RF sources for electron cyclotron resonance heating and current drive in DEMOnstration fusion power plants (DEMOs). In this paper, for the first time, a feasibility study of a 236 GHz DEMO gyrotron is presented by considering all relevant design goals and the possible technical limitations. A mode-selection procedure is proposed in order to satisfy the multi-frequency and frequency-step tunability requirements. An effective systematic design approach for the optimal design of a gradually tapered cavity is presented. The RF-behavior of the proposed cavity is verified rigorously, supporting 920 kW of stable output power with an interaction efficiency of 36% including the considerations of realistic beam parameters.

  18. Design of cavities of a standing wave accelerating tube for a 6 MeV electron linear accelerator

    Directory of Open Access Journals (Sweden)

    S Zarei

    2017-08-01

    Full Text Available Side-coupled standing wave tubes in  mode are widely used in the low-energy electron linear accelerator, due to high accelerating gradient and low sensitivity to construction tolerances. The use of various simulation software for designing these kinds of tubes is very common nowadays. In this paper, SUPERFISH code and COMSOL are used for designing the accelerating and coupling cavities for a 6 MeV electron linear accelerator. Finite difference method in SUPERFISH code and Finite element method in COMSOL are used to solve the equations. Besides, dimension of accelerating and coupling cavities and also coupling iris dimension are optimized to achieve resonance frequency of 2.9985 MHz and coupling constant of 0.0112. Considering the results of this study and designing of the RF energy injection port subsequently, the construction of 6 MeV electron tube will be provided

  19. A contribution to computer analysis of coupled-cavity traveling wave tubes. [design study for CTS satellite

    Science.gov (United States)

    Connolly, D. J.; Omalley, T. A.

    1977-01-01

    A flexible accurate large-signal computer program has been developed for the design of coupled-cavity traveling wave tubes. The program is written for a TSS-360 time sharing system. The beam is described by a disk model and the slow wave structure by a sequence of cavities or cells. The computational approach is arranged so that each cavity may have different geometrical or electrical parameters than its neighbors. This allows the program user to simulate a tube of almost arbitrary complexity. Input and output couplers, severs, complicated velocity tapers, and other features peculiar to one or a few cavities may be modeled by a correct choice of input data. The beam-wave interaction is handled by a new approach in which the RF fields are expanded in solutions to the TM wave equation retaining all significant space harmonics. The program was used to perform a design study of the TWT developed for the CTS satellite. Good agreement was obtained between the predictions of the program and the measured performance of the flight tube. The internal check on power balance was satisfied within plus or minus 0.2 per cent of input beam power.

  20. On active disturbance rejection based control design for superconducting RF cavities

    Science.gov (United States)

    Vincent, John; Morris, Dan; Usher, Nathan; Gao, Zhiqiang; Zhao, Shen; Nicoletti, Achille; Zheng, Qinling

    2011-07-01

    Superconducting RF (SRF) cavities are key components of modern linear particle accelerators. The National Superconducting Cyclotron Laboratory (NSCL) is building a 3 MeV/u re-accelerator (ReA3) using SRF cavities. Lightly loaded SRF cavities have very small bandwidths (high Q) making them very sensitive to mechanical perturbations whether external or self-induced. Additionally, some cavity types exhibit mechanical responses to perturbations that lead to high-order non-stationary transfer functions resulting in very complex control problems. A control system that can adapt to the changing perturbing conditions and transfer functions of these systems would be ideal. This paper describes the application of a control technique known as "Active Disturbance Rejection Control" (ARDC) to this problem.

  1. External-cavity solid-state organic lasers: Design rules and application perspectives (Conference Presentation)

    Science.gov (United States)

    Chénais, Sébastien; Gallinelli, Thomas; Mhibik, Oussama; Blanchard, Cédric; Forget, Sébastien

    2016-09-01

    Among various laser architectures currently used to make lasers out of organic materials (distributed feedback lasers or organic vertical cavity surface-emitting lasers, ....), vertical EXTERNAL cavities have several distinctive features that enable making lasers with a high brightness, resulting from a combination of high efficiency and good beam quality, and also offer a superior flexibility to monitor the laser spectrum. In this talk I will highlight a few recent results on external-cavity organic lasers and reveal their potential through the example of a single mode organic laser device with an ultranarrow linewidth (art). From the material point of view, I will also show how ink-jet printing can be successfully used in vertical external-cavity organic lasers to make thick and optical-quality films that have the potential to be easily produced with a high throughput.

  2. A laser feedback control design for passive ring laser gyros in a very high finesse cavity

    Science.gov (United States)

    Lorenz, M. A.

    1985-12-01

    The Frank J. Seiler Research Laboratory is currently developing a Passive Resonant Ring Laser Gyroscope (PRRLG) enclosing 58 sq m for proposed use in testing high precision rate sensors and for possibly validating the Theory of General Relativity. The sensitivities required for such experiments are in the 10 to the minus 7th power to 10 to the minus 10th power Earth Rate Unit (ERU) range. This high sensitivity necessitates the use of a large, high finesse cavity. In dealing with high finesse cavities new considerations arise. For example, the cavity linewidth is narrower than linewidths of commercially available stabilized He-Ne lasers. The stability of the laser then becomes the limiting factor in the performance of the PRRLG because of the increased signal-to-noise ratio that arises in this situation. In addition, high finesse cavities exhibit photon lifetimes on the order of 10 to the minus 3rd power to 10 to the minus 6th power seconds, which limits the bandwidth of practical controllers. In this research, a PRRLG was constructed in which a He-Ne laser was frequency locked to 25,000 finesse, 169 sq. cm. resonant cavity, as opposed to the more traditional technique of locking the resonant condition of the cavity to the laser frequency.

  3. AIDA: Asteroid Impact & Deflection Assessment

    Science.gov (United States)

    Cheng, A. F.; Galvez, A.; Carnelli, I.; Michel, P.; Rivkin, A.; Reed, C.

    2012-12-01

    To protect the Earth from a hazardous asteroid impact, various mitigation methods have been proposed, including deflection of the asteroid by a spacecraft impact. AIDA, consisting of two mission elements, the Double Asteroid Redirection Test (DART) and the Asteroid Impact Monitoring (AIM) mission, is a demonstration of asteroid deflection. To date, there has been no such demonstration, and there is major uncertainty in the result of a spacecraft impact onto an asteroid, that is, the amount of deflection produced by a given momentum input from the impact. This uncertainty is in part due to unknown physical properties of the asteroid surface, such as porosity and strength, and in part due to poorly understood impact physics such that the momentum carried off by ejecta is highly uncertain. A first mission to demonstrate asteroid deflection would not only be a major step towards gaining the capability to mitigate an asteroid hazard, but in addition it would return unique information on an asteroid's strength, other surface properties, and internal structure. This information return would be highly relevant to future human exploration of asteroids. We report initial results of the AIDA joint mission concept study undertaken by the Johns Hopkins Applied Physics Laboratory and ESA with support from NASA centers including Goddard, Johnson and Jet Propulsion Laboratory. For AIDA, the DART spacecraft impactor study is coordinated with an ESA study of the AIM mission, which would rendezvous with the same asteroid to measure effects of the impact. Unlike the previous Don Quijote mission study performed by ESA in 2005-2007, DART envisions an impactor spacecraft to intercept the secondary member of a binary near-Earth asteroid. DART includes ground-based observations to measure the deflection independently of the rendezvous spacecraft observations from AIM, which also measures deflection and provides detailed characterization of the target asteroid. The joint mission AIDA

  4. Influence of different composite materials and cavity preparation designs on the fracture resistance of mesio-occluso-distal inlay restoration.

    Science.gov (United States)

    Tekçe, Neslihan; Pala, Kansad; Demirci, Mustafa; Tuncer, Safa

    2016-01-01

    The aim of the study to evaluate the fracture resistance of a computer-aided design/computer-aided manufacturing (CAD/CAM) and three indirect composite materials for three different mesio-occluso-distal (MOD) inlay cavity designs. A total of 120 mandibular third molar were divided into three groups: (G1) non-proximal box, (G2) 2-mm proximal box, and (G3) 4-mm proximal box. Each cavity design received four composite materials: Estenia, Epricord (Kuraray, Japan), Tescera (Bisco, USA), and Cerasmart CAD/CAM blocks (GC, USA). The specimens were subjected to a compressive load at a crosshead speed of 1 mm/min. The data was analyzed using the two-way analysis of variance and Bonferroni post hoc test (p<0.05). Estenia exhibited significantly higher fracture strength than Epricord and Cerasmart in G1. In G2 and G3, there was no significant difference among the four materials. Using a non-proximal box design for the cavity can improve the fracture resistance of the inlay restoration.

  5. Elevator deflections on the icing process

    Science.gov (United States)

    Britton, Randall K.

    1990-01-01

    The effect of elevator deflection of the horizontal stabilizer for certain icing parameters is investigated. Elevator deflection can severely change the lower and upper leading-edge impingement limits, and ice can accrete on the elevator itself. Also, elevator deflection had practically no effect on the maximum local collection efficiency. It is shown that for severe icing conditions (large water droplets), elevator deflections that increase the projected height of the airfoil can significantly increase the total collection efficiency of the airfoil.

  6. Design of microcavities in diamond-based photonic crystals by Fourier- and real-space analysis of cavity fields

    CERN Document Server

    Riedrich-Möller, Janine; Becher, Christoph

    2010-01-01

    We present the design of two-dimensional photonic crystal microcavities in thin diamond membranes well suited for coupling of color centers in diamond. By comparing simulated and ideal field distributions in Fourier and real space and by according modification of air hole positions and size, we optimize the cavity structure yielding high quality factors up to Q = 320000 with a modal volume of V = 0.35 (lambda/n)^3. Using the very same approach we also improve previous designs of a small modal volume microcavity in silicon, gaining a factor of 3 in cavity Q. In view of practical realization of photonic crystals in synthetic diamond films, it is necessary to investigate the influence of material absorption on the quality factor. We show that this influence can be predicted by a simple model, replacing time consuming simulations.

  7. Mission Analysis For the Ion Beam Deflection of Fictitious Asteroid 2015PDC

    CERN Document Server

    Bombardelli, Claudio; Cano, Juan Luis

    2015-01-01

    A realistic mission scenario for the deflection of fictitious asteroid 2015PDC is investigated that makes use of the ion beam shepherd concept as primary deflection technique. The article deals with the design of a low thrust rendezvous trajectory to the asteroid, the estimation of the propagated covariance ellipsoid and the outcome of a slow-push deflection starting from three worst case scenarios (impacts in New Delhi, Dhaka and Teheran). Displacing the impact point towards very low populated areas, as opposed to full deflection, is found to be the simplest and most effective mitigation approach. Mission design, technical and political aspects are discussed.

  8. Design of a 3D photonic band gap cavity in a diamond-like inverse woodpile photonic crystal

    CERN Document Server

    Woldering, Léon A; Vos, Willem L

    2014-01-01

    We theoretically investigate the design of cavities in a three-dimensional (3D) inverse woodpile photonic crystal. This class of cubic diamond-like crystals has a very broad photonic band gap and consists of two perpendicular arrays of pores with a rectangular structure. The point defect that acts as a cavity is centred on the intersection of two intersecting perpendicular pores with a radius that differs from the ones in the bulk of the crystal. We have performed supercell bandstructure calculations with up to $5 \\times 5 \\times 5$ unit cells. We find that up to five isolated and dispersionless bands appear within the 3D photonic band gap. For each isolated band, the electric-field energy is localized in a volume centred on the point defect, hence the point defect acts as a 3D photonic band gap cavity. The mode volume of the cavities resonances is as small as 0.8 $\\lambda^{3}$ (resonance wavelength cubed), indicating a strong confinement of the light. By varying the radius of the defect pores we found that o...

  9. The cavity resonator design: stochastic optimization of the transmission line method

    Science.gov (United States)

    Jurečka, Stanislav; Müllerová, Jarmila; Dado, Milan

    2012-02-01

    Stable cavity resonators provide an ideal solution for high quality applications in telecommunications, laser sources, sensors, oscillators and filters, instrumentation and other large area of applications. For the determination of the electromagnetic field (EMF) properties in a cavity resonator several numerical methods are widely used. In our approach we used the transmission line modeling method (TLM). It is a wide-band time-domain numerical method suitable for solution of the electromagnetic field in a studied region. TLM method is based on the isomorphism between the theory of passive electrical network and the wave equation describing the properties of the EMF. TLM method offers two important advantages over the time-domain techniques such as the finite-difference time domain methods. The electric and magnetic field are resolved synchronously in time and space and TLM in implicitly stable method due to the mapping to electrical circuits. The EMF in the rectangular cavity is in our approach determined by the TLM method and the frequency spectrum is computed by the Fourier transform of the time signal. The theoretical model of the cavity EMF power spectral density function contains information about the geometrical configuration of the resonator. In our work we use the genetic algorithm for the determination of optimal dimensions of the cavity resonator expected for the proposed output resonant frequency. The stochastic modification of the theoretical model parameters is controlled by the genetic operators of mutation, crossover and selection, leading to overall improvement of the theoretical model estimation during the optimization process.

  10. Design and Analysis of Enhanced Modulation Response in Integrated Coupled Cavities DBR Lasers Using Photon-Photon Resonance

    OpenAIRE

    Paolo Bardella; Chow, Weng W.; Ivo Montrosset

    2016-01-01

    In the last few decades, various solutions have been proposed to increase the modulation bandwidth and, consequently, the transmission bit-rate of semiconductor lasers. In this manuscript, we discuss a design procedure for a recently proposed laser cavity realized with the monolithic integration of two distributed Bragg reflector (DBR) lasers allowing one to extend the modulation bandwidth. Such an extension is obtained introducing in the dynamic response a photon-photon resonance (PPR) at a ...

  11. Numerical design and model measurements for a 1.3 GHz microtron accelerating cavity

    Science.gov (United States)

    Kleeven, W. J. G. M.; Theeuwen, M. E. H. J.; Knoben, M. H. M.; Moerdijk, A. J.; Botman, J. I. M.; van der Heide, J. A.; Timmermans, C. J.; Hagedoorn, H. L.

    1992-05-01

    As part of the free electron laser project TEUFEL, a 25 MeV racetrack microtron is under construction at the Eindhoven University. The accelerating cavity of this microtron is a standing wave on axis coupled structure. It consists of three accelerating cells and two coupling cells. Numerical field calculations for this cavity were done with the computer codes SUPERFISH, URMEL-T and MAFIA. Not only the accelerating modes but also the dangerous beam breakup modes were calculated with MAFIA. An aluminium, scale 1:1 model of the structure was made in order to measure various cavity properties. Field profiles were measured with the perturbation ball method. An equivalent LC-circuit simulation of the accelerating structure was made, which serves as a model for the interpretation of the results.

  12. Thermal analysis and water-cooling design of the CSNS MEBT 324 MHz buncher cavity

    Institute of Scientific and Technical Information of China (English)

    LIU Hua-Chang; OUYANG Hua-Fu

    2008-01-01

    At least two bunchers are needed in the 3 MeV H- Medium Energy Beam Transport(MEBT)line located between RFQ and DTL for the CSNS(China Spallation Neutron Source).A nose-cone geometry has been adopted as the type of buncher cavity for its simplicity,higher impedance and lower risk of multipacting.By making use of the results got from the simulations on the buncher with two-dimension code SUPERFISH,the thermal and structural analyses have been carried out,the process and results to determine the resulting frequency shift due to thermal and structural distortion of the cavity are presented,the water-cooling channel position and the optimum cooling water temperature as well as the tuning method by adjusting the cooling water temperature when the cavity is out of resonance are also determined through the analyses.

  13. Thermal analysis and water-cooling design of the CSNS MEBT 324 MHz buncher cavity

    Science.gov (United States)

    Liu, Hua-Chang; Ouyang, Hua-Fu

    2008-04-01

    At least two bunchers are needed in the 3 MeV H- Medium Energy Beam Transport (MEBT) line located between RFQ and DTL for the CSNS (China Spallation Neutron Source). A nose-cone geometry has been adopted as the type of buncher cavity for its simplicity, higher impedance and lower risk of multipacting. By making use of the results got from the simulations on the buncher with two-dimension code SUPERFISH, the thermal and structural analyses have been carried out, the process and results to determine the resulting frequency shift due to thermal and structural distortion of the cavity are presented, the water-cooling channel position and the optimum cooling water temperature as well as the tuning method by adjusting the cooling water temperature when the cavity is out of resonance are also determined through the analyses.

  14. Recent progress in opto-mechanical design of cavity developed for the OSQAR experiment

    Science.gov (United States)

    Macúchová, Karolina; Hošek, Jan; Němcová, Šárka; &šulc, Miroslav; Zicha, Josef

    2013-05-01

    Two optical methods are used in the laser-based experiment OSQAR at CERN for the search of axions and axion-like particles. The first method looks as light shining through the wall. The second one wants to measure the ultra-fine vacuum magnetic birefringence. Both methods have reached its attainable limits of sensitivity. Present work is focused on increasing the number of photons and their endurance time within the magnetic field using a laser cavity. Presented paper covers recent state of development of a prototype of a 1 meter long laser cavity which is the prerequisite of further development of the experiment.

  15. Design of a Normal Conducting Cavity for Arrival Time Stabilization at FLASH

    CERN Document Server

    Fakhari, M.; Pfeiffer, S.; Schlarb, H.; Rossbach, J.

    2016-01-01

    The long range longitudinal wakefield calculation results are reported to investigate the cavity performance for multibeam operation up to 3 MHz bunch repetition rate. The results declare that the influence of the long range wakefield on the arrival time jitter is less than 1 fs.

  16. A Laser Feedback Control Design for Passive Ring Laser Gyros in a Very High Finesse Cavity.

    Science.gov (United States)

    1985-12-01

    14 II. Theory ....................... 16 Optical Cavities ................ 16 Laser Fundamentals ...............24 The Gaussian Beam. ...............28...c 1-(ABC 1h(.8 = (2.18) F = 1 2.19) - (RARCRD) t = = (2.20) C c[i- (RARRc%)] Laser Fundamentals A laser consists of three basic components: a gain

  17. Ferrite Characterization for the Design of an Accelerating Cavity With Perpendicular Biasing

    CERN Document Server

    Eberhardt, Johannes; Vollinger, Christine

    2016-01-01

    A perpendicular biased ferrite loaded accelerating cavity is studied for a possible upgrade of the CERN accelerator complex which could help to overcome the intensity limitations occurring at the SPS injection. The required accelerating cavity should cover a frequency range of 18 to 40 MHz with high cavity Q, which poses high demands on the ferrite material properties. A test setup is presented to measure the relative permeability and magnetic losses of full scale ferrite garnets (350 mm outer and 200 mm inner diameter) in a magnetic bias field within the frequency range of interest. An one-port reflection measurement provides adequate input to model the relative permeability of the ferrite in numerical simulations for different magnetic bias fields. A resonant measurement setup was used to cross-check simulation results with measurement data and to investigate the magnetic losses of the ferrite material. A numerical model of a simplified accelerating cavity is used to study the capability of the garnet G-510...

  18. Impact of polymer film thickness and cavity size on polymer flow during embossing : towards process design rules for nanoimprint lithography.

    Energy Technology Data Exchange (ETDEWEB)

    Schunk, Peter Randall; King, William P. (Georgia Institute of Technology, Atlanta, GA); Sun, Amy Cha-Tien; Rowland, Harry D. (Georgia Institute of Technology, Atlanta, GA)

    2006-08-01

    This paper presents continuum simulations of polymer flow during nanoimprint lithography (NIL). The simulations capture the underlying physics of polymer flow from the nanometer to millimeter length scale and examine geometry and thermophysical process quantities affecting cavity filling. Variations in embossing tool geometry and polymer film thickness during viscous flow distinguish different flow driving mechanisms. Three parameters can predict polymer deformation mode: cavity width to polymer thickness ratio, polymer supply ratio, and Capillary number. The ratio of cavity width to initial polymer film thickness determines vertically or laterally dominant deformation. The ratio of indenter width to residual film thickness measures polymer supply beneath the indenter which determines Stokes or squeeze flow. The local geometry ratios can predict a fill time based on laminar flow between plates, Stokes flow, or squeeze flow. Characteristic NIL capillary number based on geometry-dependent fill time distinguishes between capillary or viscous driven flows. The three parameters predict filling modes observed in published studies of NIL deformation over nanometer to millimeter length scales. The work seeks to establish process design rules for NIL and to provide tools for the rational design of NIL master templates, resist polymers, and process parameters.

  19. Crab cavities: Past, present, and future of a challenging device

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Q. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-05-03

    In two-ring facilities operating with a crossing-angle collision scheme, luminosity can be limited due to an incomplete overlapping of the colliding bunches. Crab cavities then are introduced to restore head-on collisions by providing the destined opposite deflection to the head and tail of the bunch. An increase in luminosity was demonstrated at KEKB with global crab-crossing, while the Large Hardron Collider (LHC) at CERN currently is designing local crab crossing for the Hi-Lumi upgrade. Future colliders may investigate both approaches. In this paper, we review the challenges in the technology, and the implementation of crab cavities, while discussing experience in earlier colliders, ongoing R&D, and proposed implementations for future facilities, such as HiLumi-LHC, CERN’s compact linear collider (CLIC), the international linear collider (ILC), and the electron-ion collider under design at BNL (eRHIC).

  20. Crab Cavities: Past, Present, and Future of a Challenging Device

    CERN Document Server

    Wu, Q

    2015-01-01

    In two-ring facilities operating with a crossing-angle collision scheme, luminosity can be limited due to an incomplete overlapping of the colliding bunches. Crab cavities then are introduced to restore head-on collisions by providing the destined opposite deflection to the head and tail of the bunch. An increase in luminosity was demonstrated at KEKB with global crab- crossing, while the Large Hardron Collider (LHC) at CERN currently is designing local crab crossing for the Hi-Lumi upgrade. Future colliders may investigate both approaches. In this paper, we review the challenges in the technology, and the implementation of crab cavities, while discussing experience in earlier colliders, ongoing R&D, and proposed implementations for future facilities, such as HiLumi-LHC, CERN’s compact linear collider (CLIC), the international linear collider (ILC), and the electronion collider under design at BNL (eRHIC).

  1. Design of a mechanism to simulate the quasi-static moment-deflection behaviour of the osteoligamentous structure of the C3-C4 cervical spine segment in the flexion-extension and lateral bending directions.

    Science.gov (United States)

    Chen, Samuel; Arsenault, Marc; Moglo, Kodjo

    2012-11-01

    The human neck is susceptible to traumatic injuries due to impacts as well as chronic injuries caused by loads such as those attributed to the wearing of heavy headgear. To facilitate the analysis of the loads that cause injuries to the cervical spine, it is possible to replicate the human neck's behaviour with mechanical devices. The goal of this work is to lay the foundation for the eventual development of a novel mechanism used to simulate the behaviour of the cervical spine during laboratory experiments. The research presented herein focuses on the design of a mechanism capable of reproducing the non-linear relationships between moments applied to the C3 vertebra and its corresponding rotations with respect to the C4 vertebra. The geometrical and mechanical properties of the mechanism are optimized based on the ability of the latter to replicate the load-deflection profile of the osteoligamentous structure of the C3-C4 vertebral pair in the flexion-extension and lateral bending directions. The results show that the proposed design concept is capable of faithfully replicating the non-linear behaviour of the motion segment within acceptable tolerances.

  2. Multiple-bunch-length operating mode design for a storage ring using hybrid low alpha and harmonic cavity method

    Science.gov (United States)

    Gao, Weiwei; Wang, Lin; Li, Heting

    2017-03-01

    In this paper we design a simultaneous three bunch length operating mode at the HLS-II (Hefei Light Source II) storage ring by installing two harmonic cavities and minimizing the momentum compaction factor. The short bunches (2.6 mm) presented in this work will meet the requirement of coherent millimeter-wave and sub-THz radiation experiments, while the long bunches (20 mm) will efficiently increase the total beam current. Therefore, this multiple-bunch-length operating mode allows present synchrotron users and coherent millimeter-wave users (or sub THz users) to carry out their experiments simultaneously. Since the relatively low energy characteristic of HLS-II we achieve the multiple-bunch-length operating mode without multicell superconducting RF cavities, which is technically feasible.

  3. Update on the CeC PoP 704 MHz 5-cell cavity cryomodule design and fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Brutus, J. C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Belomestnykh, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stony Brook Univ., NY (United States); Ben-Zvi, I. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stony Brook Univ., NY (United States); Grimm, T. [Nioware Inc., Lansing, MI (United States); Huang, Y. [Brookhaven National Lab. (BNL), Upton, NY (United States); Jecks, R. [Nioware Inc., Lansing, MI (United States); Kelly, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Litvinenko, V. [Brookhaven National Lab. (BNL), Upton, NY (United States); Stony Brook Univ., NY (United States); Pinayev, I. [Brookhaven National Lab. (BNL), Upton, NY (United States); Reid, T. [Argonne National Lab. (ANL), Argonne, IL (United States); Skaritka, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Snydstrup, L. [Brookhaven National Lab. (BNL), Upton, NY (United States); Than, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Tuozzolo, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Xu, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Yancey, J. [Nioware Inc., Lansing, MI (United States); Gerbick, S. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-05-03

    A 5-cell SRF cavity operating at 704 MHz will be used for the Coherent Electron Cooling Proof of Principle (CeC PoP) system under development for the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. The CeC PoP experiment will demonstrate the new technique of cooling proton and ion beams that may increase the beam luminosity in certain cases, by as much as tenfold. The 704 MHz cavity will accelerate 2 MeV electrons from a 112 MHz SRF gun up to 22MeV. This paper provides an overview of the design, the project status and schedule of the 704 MHz 5-cell SRF for CeC PoP experiment.

  4. Implementation of Radio-Frequency Deflecting Devices for Comprehensive High-Energy Electron Beam Diagnosis

    Science.gov (United States)

    Craievich, Paolo; Petronio, Marco; Biedron, Sandra G.; Castronovo, Davide; Dal Forno, Massimo; Di Mitri, Simone; Faure, Nicolas; La Civita, Daniele; Penco, Giuseppe; Rumiz, Luca; Sturari, Luca; Vescovo, Roberto; Wang, Defa

    2015-02-01

    In next-generation light sources, high-brightness electron beams are used in a free-electron laser configuration to produce light for use by scientists and engineers in numerous fields of research. High-brightness beams are described for such light sources as having low transverse and longitudinal emittances, high peak currents, and low slice emittance and energy spread. The optimal generation and preservation of such high-brightness electron beams during the acceleration process and propagation to and through the photon-producing element is imperative to the quality and performance of the light source. To understand the electron beam's phase space in the accelerating section of a next-generation light source machine, we employed radio-frequency cavities operating in a deflecting mode in conjunction with a magnetic spectrometer and imaging system for both low (250 MeV) and high (1.2 GeV) electron energies. This high-resolution, high-energy system is an essential diagnostic for the optimization and control of the electron beam in the FERMI light source generating fully transversely and longitudinally coherent light in the VUV to soft x-ray wavelength regimes. This device is located at the end of the linear accelerator in order to provide the longitudinal phase space nearest to the entrance of the photon-producing beam-lines. Here, we describe the design, fabrication, characterization, commissioning, and operational implementation of this transverse deflecting cavity structure diagnostic system for the high-energy (1.2 GeV) regime.

  5. Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators

    Science.gov (United States)

    Park, Yong-Lae; Black, Richard; Moslehi, Behzad; Cutkosky, Mark; Chau, Kelvin

    2012-01-01

    Force sensing is an essential requirement for dexterous robot manipulation, e.g., for extravehicular robots making vehicle repairs. Although strain gauges have been widely used, a new sensing approach is desirable for applications that require greater robustness, design flexibility including a high degree of multiplexibility, and immunity to electromagnetic noise. This invention is a force and deflection sensor a flexible shell formed with an elastomer having passageways formed by apertures in the shell, with an optical fiber having one or more Bragg gratings positioned in the passageways for the measurement of force and deflection.

  6. Laser self-mixing interferometry in VCSELs - an ultra-compact and massproduceable deflection detection system for nanomechanical polymer cantilever sensors

    DEFF Research Database (Denmark)

    Larsson, David; Yvind, Kresten; Hvam, Jørn Märcher;

    2008-01-01

    We have realised an ultra-compact deflection detection system based on laser self-mixing interferometry in a Vertical-Cavity Surface-Emitting Laser (VCSEL). The system can be used together with polymer nanomechanical cantilevers to form chemical sensors capable of detecting less than 1nm deflection....

  7. Field distribution analysis in deflecting structures

    Energy Technology Data Exchange (ETDEWEB)

    Paramonov, V.V. [Joint Inst. for Nuclear Research, Moscow (Russian Federation)

    2013-02-15

    Deflecting structures are used now manly for bunch rotation in emittance exchange concepts, bunch diagnostics and to increase the luminosity. The bunch rotation is a transformation of a particles distribution in the six dimensional phase space. Together with the expected transformations, deflecting structures introduce distortions due to particularities - aberrations - in the deflecting field distribution. The distributions of deflecting fields are considered with respect to non linear additions, which provide emittance deteriorations during a transformation. The deflecting field is treated as combination of hybrid waves HE{sub 1} and HM{sub 1}. The criteria for selection and formation of deflecting structures with minimized level of aberrations are formulated and applied to known structures. Results of the study are confirmed by comparison with results of numerical simulations.

  8. Mechanical radiation detection via sub-Brownian lever deflections

    Science.gov (United States)

    Hammig, Mark David

    2005-07-01

    A micromechanical lever that deflects in response to the impacts of charged particles is proposed as a means of improving upon the capabilities of existing radiation detection technology. When a particle strikes an object, momentum is transferred to the impacted body. The resulting body motion can be correlated to the energy of the incident particle. The momentum detector offers promise as a highly discriminating, high-resolution tool for ion sensing. Advances required to successfully realize a spectroscopic capability have been completed; specifically, techniques for reproducibly fabricating micromechanical structures have been optimized, and an instrument that measures miniscule deflections has been developed. Even absent substantial refinement efforts, the novel coupled-cavity optical detector can resolve lever motions on the order of 1--10 picometers. A method by which the Brownian motion of the lever can be stilled has been proven which elicits reductions sufficient to measure heavy-ion impact, the deflections from which may be several orders of magnitude below the thermal vibration amplitude. Using active forcing techniques, the Brownian vibration of the microlevers has been reduced from room temperature (288 K) to sub-Kelvin temperatures, for levers vibrating in air. The mechanical factors that limit the noise reduction magnitude are discussed and methods of surmounting those limitations are identified.

  9. Sagnac interferometer for photothermal deflection spectroscopy.

    Science.gov (United States)

    Shiokawa, Naoyuki; Mizuno, Yuki; Tsuchiya, Harumasa; Tokunaga, Eiji

    2012-07-01

    Photothermal deflection spectroscopy is combined with a Sagnac interferometer to enhance the sensitivity of the absorption measurement by converting the photothermal beam deflection effect into the light intensity change by the interference effect. Because of stable light interference due to the common path, the signal intensity can be amplified without increasing the noise by extending the optical path length between a sample and a photodetector. The sensitivity is further improved by the use of focusing optics and double-pass geometry. This makes photothermal deflection spectroscopy applicable to any kind of material in the whole visible region with a xenon lamp for excitation and water or air as a deflection medium.

  10. Deflection Control in Rigid Pavements

    Science.gov (United States)

    Varunkrishna, Nulu; Jayasankar, R.

    2017-07-01

    The need for modern transportation systems together with the high demand for perpetual pavements under the drastically increasing applied loads has led to a great deal of research on concrete as a pavement material worldwide. This research indeed instigated many modifications in concrete aiming for improving the concrete properties. Pavement Quality Concrete requires higher flexural strength and fewer deflections in hardened state. Fiber reinforcement and latex modification are two reliable approaches serving the required purposes. The concrete made with these two modifications is called Polymer-modified Fiber-reinforced concrete. The present study deals with the usage of polypropylene as fiber and SBR (Styrene Butadiene Rubber) Latex as polymer. M30 grade concrete was modified by replacing cement with two different percentages of fiber (0.5%, 1.0% of weight of cement) and with three different percentages of SBR latex (10%, 15% & 20% of weight of cement).

  11. Design of Transparent Anodes for Resonant Cavity Enhanced Light Harvesting in Organic Solar Cells

    KAUST Repository

    Sergeant, Nicholas P.

    2012-01-03

    The use of an ITO-free MoO 3/Ag/MoO 3 anode to control the photon harvesting in PCDTBT:PC 70BM solar cells is proposed. At first sight, the fact that these anodes possess reduced far-field transmission compared to ITO may seem to be a disadvantage. But, despite this, we show that by carefully tuning the resonant optical cavity we can enhance the external quantum efficiency close to the band edge of PCDTBT, resulting in high photocurrent and power conversion efficiency on par with ITO. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Three dimensional finite element analysis of mandibular premolar restored with fiber post and resin composite with different cavity designs

    Directory of Open Access Journals (Sweden)

    Daraporn Sae-Lee

    2016-10-01

    Full Text Available The investigation of the stress distribution and fatigue lifetime of endodontically treated mandibular premolar with various cavity designs for access opening, restored by resin composite with or without a fiber post was performed. A 3D model of a mandibular premolar with one root canal was selected. The 11 study models of tooth structure including enamel, dentine and pulp tissue were generated with different cavity designs, i.e., Class I, Class II OM, Class II MOD, Class V, Class V pulp exposure, cortical and cancellous bone, root canal configuration, as well as fiber post. A load of 150 Newtons was applied on the lingual incline plane of the buccal cusp at an angle of 45 degrees to the long axis of the tooth. The results show that the stress distributions in all models were similar, i.e., the maximum von Mises stresses were observed at the level of the cement-enamel junction (CEJ, and the stress decreased abruptly from the outer to the inner part of the tooth. The maximum von Mises stress along the tooth axis was concentrated at the load-bearing areas, and decreased gradually from the coronal region to the apex of the root. The fatigue lifetimes of the models restored with a fiber post were greater than those without a fiber post.

  13. Design and application of robust rf pulses for toroid cavity NMR spectroscopy

    CERN Document Server

    Skinner, Thomas E; Woelk, Klaus; Gershenzon, Naum I; Glaser, Steffen J

    2010-01-01

    We present robust radio frequency (rf) pulses that tolerate a factor of six inhomogeneity in the B1 field, significantly enhancing the potential of toroid cavity resonators for NMR spectroscopic applications. Both point-to-point (PP) and unitary rotation (UR) pulses were optimized for excitation, inversion, and refocusing using the gradient ascent pulse engineering (GRAPE) algorithm based on optimal control theory. In addition, the optimized parameterization (OP) algorithm applied to the adiabatic BIR-4 UR pulse scheme enabled ultra-short (50 microsec) pulses with acceptable performance compared to standard implementations. OP also discovered a new class of non-adiabatic pulse shapes with improved performance within the BIR-4 framework. However, none of the OP-BIR4 pulses are competitive with the more generally optimized UR pulses. The advantages of the new pulses are demonstrated in simulations and experiments. In particular, the DQF COSY result presented here represents the first implementation of 2D NMR sp...

  14. Beam dynamic simulations of the CLIC crab cavity and implications on the BDS

    Energy Technology Data Exchange (ETDEWEB)

    Shinton, I.R.R., E-mail: ian.shinton@stfc.ac.uk [School of Physics and Astronomy, University of Manchester, Manchester (United Kingdom); Cockcroft Institute of Accelerator Science and Technology, Daresbury (United Kingdom); Burt, G. [Engineering Department, Lancaster University, Lancaster (United Kingdom); Cockcroft Institute of Accelerator Science and Technology, Daresbury (United Kingdom); Glasman, C.J.; Jones, R.M. [School of Physics and Astronomy, University of Manchester, Manchester (United Kingdom); Cockcroft Institute of Accelerator Science and Technology, Daresbury (United Kingdom); Wolski, A. [Department of Physics, University of Liverpool, Liverpool (United Kingdom); Cockcroft Institute of Accelerator Science and Technology, Daresbury (United Kingdom)

    2011-11-21

    The Compact Linear Collider (CLIC) is a proposed electron positron linear collider design aiming to achieve a centre of mass energy of up to 3 TeV. The main accelerating structures in CLIC operate at an X-band frequency of 11.994 GHz with an accelerating gradient of 100 MV/m. The present design requires the beams to collide at a small crossing angle of 10 mrad per line giving a resultant overall crossing angle of 20 mrad. Transverse deflecting cavities, referred to as 'Crab cavities', are installed in the beam delivery system (BDS) of linear collider designs in order to ensure the final luminosity at the interaction point (IP) is comparable to that in a head on collision. We utilise the beam tracking code PLACET combined with the beam-beam code GUINEA-PIG to calculate the resulting luminosity at the IP. We follow a similar tuning procedure to that used for the design of the ILC crab cavities and anitcrab cavities. However an unexpected loss in luminosity of 10% was observed for the 20 mrad design was observed. It was discovered that the action of the crab cavities can affect the geometric aberrations resulting from the sextupoles used to correct chromatic effects in the beam delivery system. This has direct consequences regarding the design of the present CLIC BDS.

  15. Evaluation of cuspal deflection in premolar teeth restored with low shrinkable resin composite (in vitro study).

    Science.gov (United States)

    Labib, Labib Mohamed; Nabih, Sameh Mahmoud; Baroudi, Kusai

    2015-01-01

    This study evaluated cuspal deflection in premolar teeth restored with low shrinkable resin composite. A total of 40 human premolars were used for cuspal deflection evaluation in this study. Each group was divided into four equal groups according to the type of resin composite and the adhesive used as follows: group A: Using low shrinkable resin composite (silorane) with its adhesive system; group B: Using low shrinkable composite (silorane) with G-bond; group C: Using Filtek Z350 composite with G-bond; and group D: Using Filtek Z350 composite with AdheSE. Cusp deflection was detected using Universal measuring microscope and laser horizontal metroscope. This study was done to investigate the effect of polymerization shrinkage stresses of two resin composite materials (Filtek Z350 and Filtek P90) on cuspal deflection of mesio-occluso-distal restoration. For this study, the extracted non-carious maxillary second premolars were selected. Forty teeth that showed no more than 5% variation in their dimensions were used. A significant increase in cuspal deflection of cavities restored with the methacrylate-based (Filtek Z350) compared with the silorane (P90) resin-based composites was obtained. The change in the organic matrix or materials formulation of the resin composite using silorane has a positive effect on controlling the cusp deflection.

  16. Electro-optical approach to pavement deflection management

    Science.gov (United States)

    Rish, Jeff W., III; Adcock, Avery D.; Tuan, Christopher Y.; Baker, Samuel L.; Welker, Hugh W., II; Johnson, Roger F.

    1995-07-01

    A prototype continuous deflection device, referred to as a rolling weight deflectometer (RWD), has been developed as a nondestructive evaluation tool for airfield pavements. The system consists of a rigid trailer equipped with specially designed optical triangulation pavement sensors, a high-speed data acquisition system, and a high-pressure tire/load platform assembly. Pavement sensors are mounted on a rigid box beam equipped with an internal sensor system that corrects, in real time, the relative pavement height position measurements for displacements induced in the beam by mechanical vibrations, changes in temperature, or nonuniform dynamic loads at points where the beam attaches to the frame. The device produces continuous deflection profiles that show pavement response to a moving loaded wheel along the path of travel. These deflection profiles, combined with multiple passes along a lane, provide a far more detailed picture of the pavement structural integrity than has ever before been possible, because existing evaluation tools only produce response information at discrete points. Preliminary results show deflections measured by the RWD are in general agreement with the expected pavement response for various loads. A discussion of the device configuration, preliminary data, and potential as a pavement management tool is presented.

  17. Experimental and Theoretical Deflections of Hybrid Composite Sandwich Panel under Four-point Bending Load

    Directory of Open Access Journals (Sweden)

    Jauhar Fajrin

    2017-03-01

    Full Text Available This paper presents a comparison of theoretical and experimental deflection of a hybrid sandwich panel under four-point bending load. The paper initially presents few basic equations developed under three-point load, followed by development of model under four-point bending load and a comparative analysis between theoretical and experimental results. It was found that the proposed model for predicting the deflection of hybrid sandwich panels provided fair agreement with the experimental values. Most of the sandwich panels showed theoretical deflection values higher than the experimental values, which is desirable in the design. It was also noticed that the introduction of intermediate layer does not contribute much to reduce the deflection of sandwich panel as the main contributor for the total deflection was the shear deformation of the core that mostly determined by the geometric of the samples and the thickness of the core.

  18. Design considerations and experimental observations for the TAMU air-cooled reactor cavity cooling system for the VHTR

    Science.gov (United States)

    Sulaiman, S. A.; Dominguez-Ontiveros, E. E.; Alhashimi, T.; Budd, J. L.; Matos, M. D.; Hassan, Y. A.

    2015-04-01

    The Reactor Cavity Cooling System (RCCS) is a promising passive decay heat removal system for the Very High Temperature Reactor (VHTR) to ensure reliability of the transfer of the core residual and decay heat to the environment under all off-normal circumstances. A small scale experimental test facility was constructed at Texas A&M University (TAMU) to study pertinent multifaceted thermal hydraulic phenomena in the air-cooled reactor cavity cooling system (RCCS) design based on the General Atomics (GA) concept for the Modular High Temperature Gas-Cooled Reactor (MHTGR). The TAMU Air-Cooled Experimental Test Facility is ⅛ scale from the proposed GA-MHTGR design. Groundwork for experimental investigations focusing into the complex turbulence mixing flow behavior inside the upper plenum is currently underway. The following paper illustrates some of the chief design considerations used in construction of the experimental test facility, complete with an outline of the planned instrumentation and data acquisition methods. Computational Fluid Dynamics (CFD) simulations were carried out to furnish some insights on the overall behavior of the air flow in the system. CFD simulations assisted the placement of the flow measurement sensors location. Preliminary experimental observations of experiments at 120oC inlet temperature suggested the presence of flow reversal for cases involving single active riser at both 5 m/s and 2.25 m/s, respectively and four active risers at 2.25 m/s. Flow reversal may lead to thermal stratification inside the upper plenum by means of steady state temperature measurements. A Particle Image Velocimetry (PIV) experiment was carried out to furnish some insight on flow patterns and directions.

  19. Design considerations and experimental observations for the TAMU air-cooled reactor cavity cooling system for the VHTR

    Energy Technology Data Exchange (ETDEWEB)

    Sulaiman, S. A., E-mail: shamsulamri@tamu.edu; Dominguez-Ontiveros, E. E., E-mail: elvisdom@tamu.edu; Alhashimi, T., E-mail: jbudd123@tamu.edu; Budd, J. L., E-mail: dubaiboy@tamu.edu; Matos, M. D., E-mail: mailgoeshere@gmail.com; Hassan, Y. A., E-mail: yhasssan@tamu.edu [Department of Nuclear Engineering, Texas A and M University, College Station, TX, 77843-3133 (United States)

    2015-04-29

    The Reactor Cavity Cooling System (RCCS) is a promising passive decay heat removal system for the Very High Temperature Reactor (VHTR) to ensure reliability of the transfer of the core residual and decay heat to the environment under all off-normal circumstances. A small scale experimental test facility was constructed at Texas A and M University (TAMU) to study pertinent multifaceted thermal hydraulic phenomena in the air-cooled reactor cavity cooling system (RCCS) design based on the General Atomics (GA) concept for the Modular High Temperature Gas-Cooled Reactor (MHTGR). The TAMU Air-Cooled Experimental Test Facility is ⅛ scale from the proposed GA-MHTGR design. Groundwork for experimental investigations focusing into the complex turbulence mixing flow behavior inside the upper plenum is currently underway. The following paper illustrates some of the chief design considerations used in construction of the experimental test facility, complete with an outline of the planned instrumentation and data acquisition methods. Computational Fluid Dynamics (CFD) simulations were carried out to furnish some insights on the overall behavior of the air flow in the system. CFD simulations assisted the placement of the flow measurement sensors location. Preliminary experimental observations of experiments at 120oC inlet temperature suggested the presence of flow reversal for cases involving single active riser at both 5 m/s and 2.25 m/s, respectively and four active risers at 2.25 m/s. Flow reversal may lead to thermal stratification inside the upper plenum by means of steady state temperature measurements. A Particle Image Velocimetry (PIV) experiment was carried out to furnish some insight on flow patterns and directions.

  20. Cavity-Beam-Transmitter Interaction Formula Collection with Derivation

    CERN Document Server

    Tückmantel, J

    2010-01-01

    The fundamental beam-cavity-transmitter relations for accelerating and deflecting/crab cavities are presented for steady state and time-varying situations. For completeness a compact proof of the Panofsky-Wenzel theorem is given and the fundamental beam loading theorem is derived.Also the determination of relative bunch form factors is shown.

  1. Design and Analysis of Enhanced Modulation Response in Integrated Coupled Cavities DBR Lasers Using Photon-Photon Resonance

    Directory of Open Access Journals (Sweden)

    Paolo Bardella

    2016-01-01

    Full Text Available In the last few decades, various solutions have been proposed to increase the modulation bandwidth and, consequently, the transmission bit-rate of semiconductor lasers. In this manuscript, we discuss a design procedure for a recently proposed laser cavity realized with the monolithic integration of two distributed Bragg reflector (DBR lasers allowing one to extend the modulation bandwidth. Such an extension is obtained introducing in the dynamic response a photon-photon resonance (PPR at a frequency higher than the modulation bandwidth of the corresponding single-section laser. Design guidelines will be proposed, and dynamic small and large signal simulations results, calculated using a finite difference traveling wave (FDTW numerical simulator, will be discussed to confirm the design results. The effectiveness of the design procedure is verified in a structure with PPR frequency at 35 GHz allowing one to obtain an open eye diagram for a non-return-to-zero (NRZ digital signal up to 80 GHz . Furthermore, the investigation of the rich dynamics of this structure shows that with proper bias conditions, it is possible to obtain also a tunable self-pulsating signal in a frequency range related to the PPR design.

  2. Design of Three-Dimensional Guidance Law Based on Relative Velocity Deflection Angle for Ship-Air Missile%基于相对速度偏角的舰空导弹三维制导律设计

    Institute of Scientific and Technical Information of China (English)

    赵永涛; 胡云安; 耿宝亮; 戴卫祥

    2012-01-01

    Aiming at the ship-air missile intercepting the low target, the three-dimensional relative motion between missile and target was established. The high maneuverability of the target and the measurement noise of seeker measuring line of sight(LOS) angular rate were considered,and it was also considered that terminal guidance should be carried out in three-dimensional space. The relative motion model of missile intercepting target was constructed, and the relative-velocity deflection-angle was chosen as the purpose to be zeroed. A variable-structure three-dimensional terminal guidance with strong robustness was designed based on the theory of variable structure, and the model of the guidance instruction solution was presented. The simulation result not only verifies the accuracy of solution model, and it also shows that the robustness of the designed three-dimensional variable-structure terminal guidance law is much better than that of the traditional three-dimensional terminal guidance law.%针对舰空导弹拦截掠海飞行目标问题,考虑到目标具有强机动性和导引头对低空海面目标的视线角速度量测噪声,以及末制导在三维空间中进行,在建立空间导弹拦截目标相对运动模型基础上,选择空间导弹和目标的相对速度偏角作为零化目标,设计了一种具有强鲁棒性的基于零化相对速度偏角的空间变结构末制导律,给出了导引指令信息解算模型,仿真结果不仅验证了解算模型的正确性,还表明了在对抗目标大机动和低空目标视线角速度量测噪声等方面,所设计导引律比传统的空间末制导律具有更强的鲁棒性.

  3. Ion Beam Shepherd for Asteroid Deflection

    CERN Document Server

    Bombardelli, C

    2011-01-01

    We present a novel concept to impart a continuous thrust to an Earth threatening asteroid from a hovering spacecraft without need for physical attachment nor gravitational interaction with the asteroid. The concept involves an ion thruster placed at a distance of a few asteroid diameters directing a stream of quasi-neutral plasma against the asteroid surface resulting into a net transferred momentum. As the transmitted force is independent of the asteroid mass and size the method allows deflecting subkilometer asteroids with a spacecraft much lighter when compared to a gravity tractor spacecraft of equal deflection capability. The finding could make low-cost asteroid deflection missions possible in the coming years.

  4. Design concepts of monolithic metamorphic vertical-cavity surface-emitting lasers for the 1300–1550 nm spectral range

    Energy Technology Data Exchange (ETDEWEB)

    Egorov, A. Yu., E-mail: anton@beam.ioffe.ru; Karachinsky, L. Ya.; Novikov, I. I.; Babichev, A. V.; Nevedomskiy, V. N. [Russian Academy of Sciences, Ioffe Institute (Russian Federation); Bugrov, V. E. [ITMO University (Russian Federation)

    2015-11-15

    Possible design concepts for long-wavelength vertical-cavity surface-emitting lasers for the 1300–1550 nm spectral range on GaAs substrates are suggested. It is shown that a metamorphic GaAs–InGaAs heterostructure with a thin buffer layer providing rapid transition from the lattice constant of GaAs to that of In{sub x}Ga{sub 1–x}As with an indium fraction of x < 0.3 can be formed by molecular-beam epitaxy. Analysis by transmission electron microscopy demonstrated the effective localization of mismatch dislocations in the thin buffer layer and full suppression of their penetration into the overlying InGaAs metamorphic layer.

  5. Design of resonant cavity structure for efficient high-temperature operation of single-photon avalanche photodiodes.

    Science.gov (United States)

    Zavvari, Mahdi; Abedi, Kambiz; Karimi, Mohammad

    2014-05-20

    A novel design of a single-photon avalanche photodiode (SPAD) is proposed based on resonant cavity (RC) structure, and its performance is studied. In the proposed structure, InAlAs/InGaAs distributed Bragg reflectors (DBRs) are employed as top and bottom mirrors and the quantum efficiency (QE) of the absorption region is calculated considering the effect of the RC. Results show that using 12 periods of DBRs as a bottom reflector without incorporation of a top mirror can enhance the QE to about 90% at room temperature. For this RC-enhanced SPAD, a single-photon quantum efficiency (SPQE) is obtained of about 0.35 at T=300  K. For temperatures lower than T=260  K, SPQE is about 1. Results show that although the RC doesn't affect the dark current, for a given SPQE the dark count rate is lower for the RC-SPAD.

  6. Dental cavities

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001055.htm Dental cavities To use the sharing features on this page, please enable JavaScript. Dental cavities are holes (or structural damage) in the ...

  7. Test Results of the 3.9 GHz Cavity at Fermilab

    CERN Document Server

    Solyak, N

    2004-01-01

    Fermilab is developing two types of 3.9 GHz superconducting cavities to improve performances of A0 and TTF photoinjectors. In frame of this project we have built and tested two nine-cell copper models and one 3-cell niobium accelertating cavity and series of deflecting cavities. Properties of the high order modes were carefully studied in a chain of two copper cavities at room temperature. High gradient performance were tested at helium temperature. Achieved gradients and surface resistances are exceed goal parameters. In paper we discuss results of cold tests of the 3-cell accelerating and deflecting cavities.

  8. Enhanced direct-modulated bandwidth of 37 GHz by a multi-section laser with a coupled-cavity-injection-grating design

    DEFF Research Database (Denmark)

    Bach, L.; Kaiser, W.; Reithmaier, J.P.;

    2003-01-01

    Using a new multi-section laser concept based on a coupled-cavity-injection-grating design, the material related intrinsic 3 dB modulation bandwidth can be enhanced up to 37 GHz for a 1.5 mm long device.......Using a new multi-section laser concept based on a coupled-cavity-injection-grating design, the material related intrinsic 3 dB modulation bandwidth can be enhanced up to 37 GHz for a 1.5 mm long device....

  9. Highly efficient single-longitudinal-mode {beta}-BaB{sub 2}O{sub 4} optical parametric oscillator with a new cavity design

    Energy Technology Data Exchange (ETDEWEB)

    Boon-Engering, J.M. [Nederlands Centrum voor Laser Research b.v., Postbus 2662, 7500 CR Enschede (Netherlands)]|[Department of Physics and Astronomy, Laser Centre Vrije Universiteit, De Boelelaan 1081, 1081 HV Amsterdam (Netherlands); Gloster, L.A.W. [Laser Photonics Group, Department of Physics and Astronomy, University of Manchester, Manchester M13 9PL (United Kingdom); van der Veer, W.E. [Nederlands Centrum voor Laser Research b.v., Postbus 2662, 7500 CR Enschede (Netherlands)]|[Department of Physics and Astronomy, Laser Centre Vrije Universiteit, De Boelelaan 1081, 1081 HV Amsterdam (Netherlands); McKinnie, I.T. [Laser Photonics Group, Department of Physics and Astronomy, University of Manchester, Manchester M13 9PL (United Kingdom)]|[Department of Physics, University of Otago, P.O. Box 56, Dunedin (New Zealand); King, T.A. [Laser Photonics Group, Department of Physics and Astronomy, University of Manchester, Manchester M13 9PL (United Kingdom); Hogervorst, W. [Department of Physics and Astronomy, Laser Centre Vrije Universiteit, De Boelelaan 1081, 1081 HV Amsterdam (Netherlands)

    1995-10-15

    A new coupled-cavity design for single-longitudinal-mode operation of an optical parametric oscillator (OPO) is presented. The OPO is based on a {beta}-BaB{sub 2}O{sub 4} crystal and is pumped by the third harmonic of a Nd:YAG laser. With this design, we achieved single-longitudinal-mode operation of the OPO with a decrease in the threshold and an increase in external efficiency compared with those of a conventional grazing-incidence OPO. A mathematical model that describes the mode spacings for this cavity is given. {copyright} {ital 1995} {ital Optical} {ital Society} {ital of} {ital America}.

  10. Galvanometer deflection: a precision high-speed system.

    Science.gov (United States)

    Jablonowski, D P; Raamot, J

    1976-06-01

    An X-Y galvanometer deflection system capable of high precision in a random access mode of operation is described. Beam positional information in digitized form is obtained by employing a Ronchi grating with a sophisticated optical detection scheme. This information is used in a control interface to locate the beam to the required precision. The system is characterized by high accuracy at maximum speed and is designed for operation in a variable environment, with particular attention placed on thermal insensitivity.

  11. Alaska North-South Deflections (DEFLEC96)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This 2' x 4' surface deflection of the vertical grid for Alaska is the DEFLEC96 model. The computation used about 1.1 million terrestrial and marine gravity data...

  12. Mexico East-West Deflections (DMEX97)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This 2' surface deflection of the vertical grid for Mexico, and North-Central is the DMEX97 model. The computation used about one million terrestrial and marine...

  13. Alaska East-West Deflections (DEFLEC96)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This 2' x 4' surface deflection of the vertical grid for Alaska is the DEFLEC96 model. The computation used about 1.1 millionterrestrial and marine gravity data held...

  14. Mexico North-South Deflections (DMEX97)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This 2' surface deflection of the vertical grid for Mexico, and North-Central is the DMEX97 model. The computation used about one million terrestrial and marine...

  15. Cone beam computed tomographic evaluation of two access cavity designs and instrumentation on the thickness of peri-cervical dentin in mandibular anterior teeth

    Science.gov (United States)

    Varghese, Vinny Sara; George, John V.; Mathew, Sylvia; Nagaraja, Shruthi; Indiresha, H. N.; Madhu, K. S.

    2016-01-01

    Background and Objectives: The aim of the study was to determine the effect of two access cavity designs on the peri-cervical dentin thickness before and after instrumentation using cone beam computed tomography (CBCT). Materials and Methods: Sixty mandibular anterior teeth were divided into two groups of thirty teeth each: Group I: conventional access cavity preparation, where access was prepared just above the cingulum and Group II: incisal access cavity preparation, where access was prepared in proximity to the incisal edge. CBCT scans were taken preoperatively, following access cavity preparation and post instrumentation. 200 μm thick slices were obtained 4mm apical and coronal to the cemento-enamel junction. The peri-cervical dentin thickness was calculated on the facial, lingual, mesial, and distal for all the three obtained scans. Results: The analysis showed that access cavity preparation and instrumentation resulted in a significant loss of tooth structure in Group I on all surfaces, but in Group II, there was a significant loss of tooth structure only in the mesial, lingual, and distal surfaces (P < 0.05). Conclusion: Incisal access cavity preparation resulted in lesser loss of dentin in the peri-cervical region. PMID:27656065

  16. Implementation of Input Block of Minimally Buffered Deflection NoC Router

    Directory of Open Access Journals (Sweden)

    Priti M. Shahane

    2016-08-01

    Full Text Available The traditional system on chip designs employ the shared bus architecture for data transfer in highly integrated Multiprocessor system on chips(MPSoC.Network on chip (NoCis a new paradigm for on chip communication for Multiprocessor systems on chips(MPSoCs. NoCs replace the traditional shared buses system with routing switches. Heart of the NoC is the router and it consists of an input buffer, arbiter, crossbar and an output port. The NoC router uses a buffer to store the incoming packets. These buffers improve the performance but they consume more power and area. Bufferless deflection routing is the solution for improvement in energy efficiency. In this method deflections of the packets take place to overcome the contention problem. But at high network load, deflection routing degrades the performance because of unnecessary hopping of data packets. The MinBD (minimally buffered deflection router is a new router design that uses a small buffer for bufferless deflection routing. In this paper the input block of MinBD router is implemented on FPGA which shows that a small buffer will help to reduce the network deflection rate. It also improves the performance and energy efficiency while buffering only deflected data packets.

  17. AIDA: the Asteroid Impact & Deflection Assessment mission

    Science.gov (United States)

    Vincent, Jean-Baptiste

    2016-07-01

    target by AIM, the mission will be the first fully documented impact experiment at asteroid scale, which will include the characterization of the target's properties and the outcome of the impact. By comparing our in situ measurements with ground-based data from telescopes, we can calibrate better the remote observations and improve our data interpretation of other systems. Therefore, AIDA offers a unique opportunity to test and refine our understanding and models at the actual scale of an asteroid. This will allow feeding small-body collisional evolution models with more realistic parameters to draw a more reliable story of the Solar System formation and evolution. Moreover, it will offer a first check of the validity of the kinetic impactor concept to deflect a small body trajectory and lead to improved efficiency for future kinetic impactor designs.

  18. Optimization of photonic crystal cavities

    DEFF Research Database (Denmark)

    Wang, Fengwen; Sigmund, Ole

    2017-01-01

    We present optimization of photonic crystal cavities. The optimization problem is formulated to maximize the Purcell factor of a photonic crystal cavity. Both topology optimization and air-hole-based shape optimization are utilized for the design process. Numerical results demonstrate...... that the Purcell factor of the photonic crystal cavity can be significantly improved through optimization....

  19. Mode-locked Lasers Applied to Deflecting a Near Earth Object on Collision Course with Earth

    CERN Document Server

    Fork, Richard; Burgess, Luke; Bergstue, Grant

    2013-01-01

    We consider synchronized trains of sub-picosecond pulses generated by mode-locked lasers applied to deflection of near Earth objects (NEO) on collision course with Earth. Our method is designed to avoid a predicted collision of the NEO with Earth by at least the diameter of Earth. We estimate deflecting a 10,000 MT NEO, such as the asteroid which struck Earth near Chelyabinsk, Russia to be feasible within several months using average power in the ten kilowatt range. We see this deflection method as scalable to larger NEO to a degree not possible using continuous laser systems.

  20. Photonic-based laser driven electron beam deflection and focusing structures

    Directory of Open Access Journals (Sweden)

    T. Plettner

    2009-10-01

    Full Text Available We propose a dielectric photonic structure for ultrafast deflection and focusing of relativistic charged particle beams. The structure is designed to transform a free-space laser beam into a deflection force that acts on the free particles with the same optical phase over a distance of travel that is much greater than the laser wavelength. The proposed structure has a two-dimensional geometry and is compatible with existing nanofabrication methods. Deflection fields of GV/m magnitude and subfemtosecond switching speeds are expected to be possible from these dielectric structures. With these elements a submeter scale extreme ultraviolet synchrotron source seems feasible.

  1. Design and experiments for the waveguide to coaxial cable adapter of a cavity beam position monitor%Design and experiments for the waveguide to coaxial cable adapter of a cavity beam position monitor

    Institute of Scientific and Technical Information of China (English)

    李享; 郑曙昕

    2011-01-01

    The waveguide to coaxial cable adapter is very important to the cavity beam position monitor (CBPM) because it determines how much of the energy in the cavity could be coupled outside. In this paper, the waveguide to coaxial cable adapter of a CBPM is des

  2. The Influence of the Supporting Wheel Deflection of Large-scale Rotary Kiln on Maximum Contact Stress

    Institute of Scientific and Technical Information of China (English)

    Li Xuejun; Qiu Weiliang; Yuan Yincai; Li Ping

    2006-01-01

    The relation between the maximum contact stress ratio and deflection angle is derived from Hertz contact theory when the deflection of rotary kiln supporting wheel happens. According to the analysis of practical example, the maximum contact stress ratio within the deflection range of rotary kiln supporting wheel is listed. The contact stress will increase largely when rotary kiln supporting wheel deflects with little angle,which probably will result in accidents correlating to safety. This will provide theory conference for the design,the operating condition analysis and adjusting of the rotary kiln.

  3. Measurement of Large Forces and Deflections in Microstructures

    CERN Document Server

    Hals, Kai Axel; Chen, Xuyuan

    2008-01-01

    Properties of typical MEMS materials have been widely investigated. Mechanical properties of MEMS structures depend not only on the bulk material properties, but also structural factors. A measurement system has been made to measure force/deflection on microstructures to examine some of the structural properties. This is a stylus setup integrated with a load cell and a linear actuator. First, the requirements for the measurement system were established. Then the system was built up and characterized. We have successfully made measurements on a typical micromechanical structure, a cantilever accelerometer design. The stylus placement accuracy, the spring constant along the proof mass, analysis of the force/deflection curve shape and destructive tests on the cantilever have been investigated in our experiment and will be presented in this paper.

  4. Phase-shift Cavity Ring Down Spectroscopy Set-up for NO2 Sensing : Design and Fabrication

    Directory of Open Access Journals (Sweden)

    Cherry Dhiman

    2015-03-01

    Full Text Available An indigenously designed cavity ring down spectroscopy cell of 80 cm length of mild steel material was fabricated by attaching two 1″ diameter high reflecting concave mirrors with reflectivity 99.997 % at 405 nm and radius of curvature was 1 m in specially designed mirror holding assemblies to the cell at two ends. Fine alignment of the resonator is facilitated with three tip-tilt adjusting screws to the mirror-mounting plate assembly. The PS-CRDS experimental set-up is evaluated by measuring the phase shift values corresponding to the absorption of NO2 gas filled at low pressures in the cell. The limit of detection of pure NO2 using the set-up under given conditions of Ar @ 50 mbar is estimated to be 1.50 × 1011 cm-3 and @ 60 mbar as 2 × 1011 cm-3.Defence Science Journal, Vol. 65, No. 1, January 2015, pp.25-30, DOI:http://dx.doi.org/10.14429/dsj.65.7790

  5. Design of a beam position sensitive cavity as a Schottky noise detector for mass measurements in CR rate at FAIR

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xiangcheng; Huelsmann, Peter; Nolden, Fritz; Steck, Markus [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Sanjari, Shahab [ExtreMe Matter Institute, Darmstadt (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Litvinov, Yuri [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Piotrowski, Jeremi [AGH University of Science and Technology, Krakow (Poland)

    2014-07-01

    Mass is one of fundamental characteristics of a nucleus. It plays an important role in many areas of physics, as well as other science branches. Especially in nuclear astrophysics, the masses of unstable nuclei close to nucleon drip lines are of great interests, since they are indispensable quantities for modelling nucleosynthesis processes in stellar objects. The Facility for Antiproton and Ion Research (FAIR), by providing high-intensity high-energy secondary beams, will enable unprecedented opportunities to investigate such nuclei. In particular, the collector ring (CR) is designed to be operated in the isochronous ion-optical mode as a high precision mass spectrometer. In order to satisfy the stringent requirements on accuracy and sensitivity for the future mass measurements, a non-destructive detector that is sensitive to single ions is being developed. Owing to the position sensitivity, it will be possible to correct for errors originating from different orbit lengths. In this work, we present simulation results of several possible designs of a cavity-based detector and discuss their potential applications as Schottky-noise detectors.

  6. A 3D Model of the 4GLS VUV-FEL Conceptual Design Including Improved Modelling of the Optical Feedback Cavity

    NARCIS (Netherlands)

    Thompson, N.R.; Dunning, D.J.; Mcneil, B.W.J.; Boller, Klaus J.; Karssenberg, J.G.; van der Slot, Petrus J.M.

    2006-01-01

    The Conceptual Design Report for the 4th Generation Light Source (4GLS) at Daresbury Laboratory in the UK was published in Spring 2006. The proposal includes a low-Q cavity (also called a regenerative amplifier) FEL to generate variably-polarised, temporally-coherent radiation in the photon energy

  7. Comparing deflection measurements of a magnetically steerable catheter using optical imaging and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lillaney, Prasheel, E-mail: Prasheel.Lillaney@ucsf.edu; Caton, Curtis; Martin, Alastair J.; Losey, Aaron D.; Evans, Leland; Saeed, Maythem; Cooke, Daniel L.; Wilson, Mark W.; Hetts, Steven W. [Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California 94143 (United States)

    2014-02-15

    using optical data did not demonstrate a significant difference from the angles measured using MR image data when compared using the base to tip method. Conclusions: This study validates the theoretical description of the magnetically steerable catheter, while also giving insight into different methods and modalities for measuring the deflection angles of the prototype catheters. These results can be used to mechanically model future iterations of the design. Quantifying the difference between the different methods for measuring catheter deflection will be important when making deflection measurements in future studies. Finally, MR images can be used to reliably measure deflection angles since there is no significant difference between the MR and optical measurements.

  8. Influence of deflection hole angle on effusion cooling in a real combustion chamber condition

    Directory of Open Access Journals (Sweden)

    Liu Xiao

    2015-01-01

    Full Text Available Fluid-solid coupling simulation is conducted to investigate the performance of effusion cooling in the real combustion chamber condition of strong rotation and primary holes. The wall temperature and film cooling effectiveness of different deflection angle is analyzed. From the results, it is concluded that the performance of effusion is better than conventional film cooling. The wall temperature and gradient is lower, the cooling efficiency is higher and the coolant is reduced by 20%, but pressure loss is slightly increased. The cooling effectiveness decreases behind primary holes because of local combustion. Comparison with the effect of deflection angle, the cooling performance of 60 deg deflection angle is best. The coolant is better attached to the wall downstream when the deflection angle is same as the rotating mainstream. In addition, the effect of deflection angle is not so significant on the coolant flow rate, but a large negative impact on the pressure loss. Although the cooling effectiveness of 60 deg deflection angle is highest, the total pressure recovery coefficient is lower. The maximum temperature drops about 70K and the outlet temperature distribution trends more consistent. So various factors should be taken into consideration when designing of deflection angle.

  9. Design issues for compressed air energy storage in sealed underground cavities

    Directory of Open Access Journals (Sweden)

    P. Perazzelli

    2016-06-01

    Full Text Available Compressed air energy storage (CAES systems represent a new technology for storing very large amount of energy. A peculiarity of the systems is that gas must be stored under a high pressure (p = 10–30 MPa. A lined rock cavern (LRC in the form of a tunnel or shaft can be used within this pressure range. The rock mass surrounding the opening resists the internal pressure and the lining ensures gas tightness. The present paper investigates the key aspects of technical feasibility of shallow LRC tunnels or shafts under a wide range of geotechnical conditions. Results show that the safety with respect to uplift failure of the rock mass is a necessary but not a sufficient condition for assessing feasibility. The deformation of the rock mass should also be kept sufficiently small to preserve the integrity of the lining and, especially, its tightness. If the rock is not sufficiently stiff, buckling or fatigue failure of the steel lining becomes more decisive when evaluating the feasible operating air pressure. The design of the concrete plug that seals the compressed air stored in the container is another demanding task. Numerical analyses indicate that in most cases, the stability of the rock mass under the plug loading is not a decisive factor for plug design.

  10. Design and Fabrication of 1.06 μm Resonant-Cavity Enhanced Reflective Modulator with GaInAs/GaAs Quantum Wells

    Institute of Scientific and Technical Information of China (English)

    YANG Xiao-Hong; HAN Qin; NI Hai-Qiao; HUANG She-Song; DU Yun; PENG Hong-Ling; XIONG Yong-Hua; NIU Zhi-Chuan; WU Rong-Han

    2006-01-01

    A resonant-cavity enhanced reflective optical modulator is designed and fabricated, with three groups of three highly strained InGaAs/GaAs quantum wells in the cavity, for low voltage and high contrast ratio operation.The quantum wells are positioned in antinodes of the optical standing wave. The modulator is grown in a single growth step in an molecular beam epitaxy system, using GaAs/AlAs distributed Bragg reflectors as both the top and bottom mirrors. Results show that the reflection device has a modulation extinction of 3 dB at -4.5 V bias.

  11. Crab Cavities for Linear Colliders

    Energy Technology Data Exchange (ETDEWEB)

    Burt, G.; Ambattu, P.; Carter, R.; Dexter, A.; Tahir, I.; /Cockcroft Inst. Accel. Sci. Tech. /Lancaster U.; Beard, C.; Dykes, M.; Goudket, P.; Kalinin, A.; Ma, L.; McIntosh, P.; /Daresbury; Shulte, D.; /CERN; Jones, Roger M.; /Cockcroft Inst. Accel. Sci. Tech. /Manchester U.; Bellantoni, L.; Chase, B.; Church, M.; Khabouline, T.; Latina, A.; /Fermilab; Adolphsen, C.; Li, Z.; Seryi, Andrei; /SLAC

    2011-11-08

    Crab cavities have been proposed for a wide number of accelerators and interest in crab cavities has recently increased after the successful operation of a pair of crab cavities in KEK-B. In particular crab cavities are required for both the ILC and CLIC linear colliders for bunch alignment. Consideration of bunch structure and size constraints favour a 3.9 GHz superconducting, multi-cell cavity as the solution for ILC, whilst bunch structure and beam-loading considerations suggest an X-band copper travelling wave structure for CLIC. These two cavity solutions are very different in design but share complex design issues. Phase stabilisation, beam loading, wakefields and mode damping are fundamental issues for these crab cavities. Requirements and potential design solutions will be discussed for both colliders.

  12. Crab cavities for linear colliders

    CERN Document Server

    Burt, G; Carter, R; Dexter, A; Tahir, I; Beard, C; Dykes, M; Goudket, P; Kalinin, A; Ma, L; McIntosh, P; Shulte, D; Jones, Roger M; Bellantoni, L; Chase, B; Church, M; Khabouline, T; Latina, A; Adolphsen, C; Li, Z; Seryi, Andrei; Xiao, L

    2008-01-01

    Crab cavities have been proposed for a wide number of accelerators and interest in crab cavities has recently increased after the successful operation of a pair of crab cavities in KEK-B. In particular crab cavities are required for both the ILC and CLIC linear colliders for bunch alignment. Consideration of bunch structure and size constraints favour a 3.9 GHz superconducting, multi-cell cavity as the solution for ILC, whilst bunch structure and beam-loading considerations suggest an X-band copper travelling wave structure for CLIC. These two cavity solutions are very different in design but share complex design issues. Phase stabilisation, beam loading, wakefields and mode damping are fundamental issues for these crab cavities. Requirements and potential design solutions will be discussed for both colliders.

  13. Design of Optical Tunable CNOT (XOR) and XNOR Logic Gates Based on 2D-Photonic Crystal Cavity Using Electro-Optic Effect

    CERN Document Server

    Abbasian, Karim; Sadeghi, Parvin

    2016-01-01

    We have proposed optical tunable CNOT (XOR) and XNOR logic gates using two-dimensional photonic crystal (2DPhC) cavities. Where, air rods with square lattice array have been embedded in Ag-Polymer substrate with refractive index of 1.59. In this work, we have enhanced speed of logic gates by applying two input signals with a phase dif?ference at the same wavelength for 2DPhC cavities. Where, we have adjusted the phases of input and control signals equal with {\\pi}/3 and zero, respectively. The response time of the structure and quality factor of the cavities are in the range of femtosecond and 2000, respectively. Then, we have used electro-optic property of the substrate material to change the cavities resonance wavelengths. By this means, we could design the logic gates and demonstrate a tunable range of 23nm for their operation wavelength. The quality factor and the response times of cavities remain constant in the tunable range of wavelength, approximately. The evaluated least ON to OFF logic-level contras...

  14. Design, Construction, and Initial Test of High Spatial Resolution Thermometry Arrays for Detection of Surface Temperature Profiles on SRF Cavities in Super Fluid Helium

    Energy Technology Data Exchange (ETDEWEB)

    Ari Palczewski, Rongli Geng, Grigory Eremeev

    2011-07-01

    We designed and built two high resolution (0.6-0.55mm special resolution [1.1-1.2mm separation]) thermometry arrays prototypes out of the Allen Bradley 90-120 ohm 1/8 watt resistor to measure surface temperature profiles on SRF cavities. One array was designed to be physically flexible and conform to any location on a SRF cavity; the other was modeled after the common G-10/stycast 2850 thermometer and designed to fit on the equator of an ILC (Tesla 1.3GHz) SRF cavity. We will discuss the advantages and disadvantages of each array and their construction. In addition we will present a case study of the arrays performance on a real SRF cavity TB9NR001. TB9NR001 presented a unique opportunity to test the performance of each array as it contained a dual (4mm separation) cat eye defect which conventional methods such as OST (Oscillating Superleak second-sound Transducers) and full coverage thermometry mapping were unable to distinguish between. We will discuss the new arrays ability to distinguish between the two defects and their preheating performance.

  15. Influence of Cavity Margin Design and Restorative Material on Marginal Quality and Seal of Extended Class II Resin Composite Restorations In Vitro.

    Science.gov (United States)

    Soliman, Sebastian; Preidl, Reinhard; Karl, Sabine; Hofmann, Norbert; Krastl, Gabriel; Klaiber, Bernd

    2016-01-01

    To investigate the influence of three cavity designs on the marginal seal of large Class II cavities restored with low-shrinkage resin composite limited to the enamel. One hundred twenty (120) intact human molars were randomly divided into 12 groups, with three different cavity designs: 1. undermined enamel, 2. box-shaped, and 3. proximal bevel. The teeth were restored with 1. an extra-low shrinkage (ELS) composite free of diluent monomers, 2. microhybrid composite (Herculite XRV), 3. nanohybrid composite (Filtek Supreme XTE), and 4. silorane-based composite (Filtek Silorane). After artificial aging by thermocycling and storage in physiological saline, epoxy resin replicas were prepared. To determine the integrity of the restorations' approximal margins, two methods were sequentially employed: 1. replicas were made of the 120 specimens and examined using SEM, and 2. the same 120 specimens were immersed in AgNO3 solution, and the dye penetration depth was observed with a light microscope. Statistical analysis was performed using the Kruskal-Wallis and the Dunn-Bonferroni tests. After bevel preparation, SEM observations showed that restorations did not exhibit a higher percentage of continuous margin (SEM-analysis; p>0.05), but more leakage was found than with the other cavity designs (pcomposite restorations and is no longer recommended. However, undermined enamel should be removed to prevent enamel fractures.

  16. Mucoadhesive Gels Designed for the Controlled Release of Chlorhexidine in the Oral Cavity

    Directory of Open Access Journals (Sweden)

    Adamo Fini

    2011-09-01

    Full Text Available This study describes the in vitro/ex vivo buccal release of chlorhexidine (CHX from nine mucoadhesive aqueous gels, as well as their physicochemical and mucoadhesive properties: CHX was present at a constant 1% w/v concentration in the chemical form of digluconate salt. The mucoadhesive/gel forming materials were carboxymethyl- (CMC, hydroxypropylmethyl- (HPMC and hydroxypropyl- (HPC cellulose, alone (3% w/w or in binary mixtures (5% w/w; gels were tested for their mucoadhesion using the mucin method at 1, 2 and 3% w/w concentrations. CHX release from different formulations was assessed using a USP method and newly developed apparatus, combining release/permeation process in which porcine mucosa was placed in a Franz cell. The combination of HPMC or HPC with CMC showed slower drug release when compared to each of the individual polymers. All the systems proved suitable for CHX buccal delivery, being able to guarantee both prolonged release and reduced transmucosal permeation. Gels were compared for the release of previously studied tablets that contained Carbopol and HPMC, alone or in mixture. An accurate selection and combination of the materials allow the design of different pharmaceutical forms suitable for different purposes, by simply modifying the formulation compositions.

  17. Small angle electron diffraction and deflection

    Directory of Open Access Journals (Sweden)

    T. Koyama

    2012-03-01

    Full Text Available Electron optical system is constructed in order to obtain small angle diffraction and Lorentz deflection of electrons at the order of down to 10-6 radian in the reciprocal space. Long-distance camera length up to 3000 m is achieved in a conventional transmission electron microscope with LaB6 thermal emission type. The diffraction pattern at 5 × 10-6 radian is presented in a carbon replica grating with 500 nm lattice spacing while the magnetic deflection pattern at 2 × 10-5 radian is exhibited in Permalloy elements. A simultaneous recording of electron diffraction and Lorentz deflection is also demonstrated in 180 degree striped magnetic domains of La0.825Sr0.175MnO3.

  18. The influence of the cavity preparation design on marginal accuracy of laboratory-processed resin composite restorations.

    Science.gov (United States)

    Fonseca, Rodrigo Borges; Correr-Sobrinho, Lourenço; Fernandes-Neto, Alfredo Júlio; Quagliatto, Paulo Sérgio; Soares, Carlos José

    2008-03-01

    The aim of this study was to evaluate the influence of different cavity preparation designs on marginal accuracy of laboratory-processed resin composite restored teeth. Eighty mandibular human third molars were selected. There were two experimental factors, occlusal isthmus width (narrow vs wide) and cuspal coverage (inlay, one-cusp onlay, two-cusp onlay, and all-cusp onlay), resulting on eight groups (N = 10). Indirect composite restorations (SR Adoro, Ivoclar-Vivadent) were manufactured and positioned over each respective preparation. Marginal accuracy evaluation was accomplished using a stereomicroscope at three points on buccal, lingual, mesial, and distal regions with 40x magnification. The results showed significant differences (P = 0.00) with wide inlay showing the best overall marginal accuracy and narrow inlay the worst one. Two-way analysis of variance (ANOVA) showed significant differences when considering the factor occlusal isthmus width (P = 0.00). In general, preparations with wide occlusal isthmus presented better results than narrow ones, except for wide all-cusp onlays; however, the test failed to show differences when considering the cuspal coverage (P = 0.42) or the interaction between both factors (P = 0.30). The effect of occlusal width extension on marginal accuracy of indirect composite resin restorations is significant, with lower values of gaps width in wide preparations, but since in a clinical situation this would mean greater removal of sound tooth structure, less-aggressive preparations combined with other restorative procedures seem to be more feasible.

  19. The adhesive potential of dentin bonding systems assessed using cuspal deflection measurements and cervical microleakage scores.

    Science.gov (United States)

    Sultan, Ahmed; Moorthy, Advan; Fleming, Garry J P

    2014-10-01

    To assess the cuspal deflection and cervical microleakage of standardized mesio-occluso-distal (MOD) cavities restored with a dimethacrylate resin-based-composite (RBC) placed with one 3-step, one 2-step and three 1-step bonding systems and compared with the unbound condition. Forty-eight sound maxillary premolar teeth with standardized MOD cavities were randomly allocated to six groups. Restoration was performed in eight oblique increments using a quartz-tungsten-halogen (QTH) light curing unit (LCU) with the bonding condition as the dependent variable. Buccal and palatal cuspal deflections were recorded post-irradiation using a twin channel deflection measuring gauge at 0, 30, 60 and 180s. Following restoration, the teeth were thermocycled, immersed in a 0.2% basic fuchsin dye for 24h, sectioned and examined for cervical microleakage assessment. The mean total cuspal deflection measurements with the one 3-step, one 2-step and three 1-step bonding systems were 11.26 (2.56), 10.95 (2.16), 10.03 (2.05) (Futurabond(®) DC SingleDose), 6.37 (1.37) (Adper™ Prompt™ L-Pop™), 8.98 (1.34) μm (All-Bond SE(®)), respectively when compared with the unbound condition (6.46 (1.88) μm) The one-way ANOVA of the total cuspal deflection measurements identified statistical differences (pbonding system although differences between the bonding systems were evident (pbonding technologies available to practitioners for RBCs. Poorly performing adhesives can be identified which indicated the technique may be useful as a screening tool for assessing existing and new bonding technologies which offers the potential to limit complications routinely encountered with Class II RBC restorations. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  20. The influence of cavity preparation design on fracture strength and mode of fracture of laboratory-processed composite resin restorations.

    Science.gov (United States)

    Fonseca, Rodrigo Borges; Fernandes-Neto, Alfredo Julio; Correr-Sobrinho, Lourenco; Soares, Carlos Jose

    2007-10-01

    Removal of large amounts of sound tooth structure may result in a weakened restored tooth. Nevertheless, removal of tooth structure for cuspal coverage has been recommended to protect teeth restored with laboratory-processed composite resin (LPCR) from fracture. The purpose of this study was to evaluate the influence of different cavity preparation designs on fracture strength and modes of fracture of teeth restored with LPCR. Ninety anatomically similar human third mandibular molars were selected. There were 2 experimental factors, occlusal isthmus width (narrow versus wide) and cuspal coverage (inlay, 1-cusp onlay, 2-cusp onlay, and all-cusp onlay), and 1 control group that received no treatment, resulting in 9 groups (n=10). Indirect composite resin (SR Adoro) restorations were manufactured and adhesively cemented with Adper Single Bond 2 and Rely-X ARC. A compressive loading test (0.5 mm/min) was performed. The modes of fracture were classified according to 4 categories. One-way and 2-way ANOVA followed by Tukey-HSD test were used to statistically analyze the fracture load data (alpha =.05). The statistical analysis failed to show significant differences among restored groups but showed differences between these groups and the control group (P = .001). Two-way ANOVA failed to show any difference when considering the occlusal isthmus width alone (P = .98), cuspal coverage (P = .273), or the interaction between these factors (P = .972). Several teeth had fractures affecting a great amount of both restoration and tooth structure. This in vitro study showed restored teeth having similar fracture strength and fracture modes, suggesting that with the tested preparation designs, there is no advantage of cuspal coverage to protect LPCR restored teeth from fracture.

  1. Design, construction and evaluation of a 12.2 GHz, 4.0 kW-CW coupled-cavity traveling wave tube

    Science.gov (United States)

    Ayers, W. R.; Harman, W. A.

    1973-01-01

    An analytical and experimental program to study design techniques and to utilize these techniques to optimize the performance of an X-band 4 kW, CW traveling wave tube ultimately intended for satellite-borne television broadcast transmitters is described. The design is based on the coupled-cavity slow-wave circuit with velocity resynchronization to maximize the conversion efficiency. The design incorporates a collector which is demountable from the tube. This was done to facilitate multistage depressed collector experiments employing a NASA designed axisymmetric, electrostatic collector for linear beam microwave tubes after shipment of the tubes to NASA.

  2. Spent-beam refocusing analysis and multistage depressed collector design for a 75-W, 59- to 64-GHz coupled-cavity traveling-wave tube

    Science.gov (United States)

    Wilson, Jeffrey D.; Ramins, Peter; Force, Dale A.

    1990-01-01

    A computational design technique for coupled-cavity tubes (TWTs) equipped with spent-beam refocusers (SBRs) and multistage depressed collectors (MDCs) is described. A large-signal multidimensional computer program was used to analyze the TWT-SBR performance and to generate the spent-beam models used for MDC design. The results of a design involving a 75-W, 59 to 64 GHz TWT are presented. The SBR and MDC designs are shown, and the computed TWT, SBR, and MDC performances are described. Collector efficiencies in excess of 94 percent led to projected overall TWT efficiencies in the 40-percent range.

  3. Deflection unit for multi-beam mask making

    Science.gov (United States)

    Letzkus, Florian; Butschke, Joerg; Irmscher, Mathias; Jurisch, Michael; Klingler, Wolfram; Platzgummer, Elmar; Klein, Christof; Loeschner, Hans; Springer, Reinhard

    2008-10-01

    Two main challenges of future mask making are the decreasing throughput of the pattern generators and the insufficient line edge roughness of the resist structures. The increasing design complexity with smaller feature sizes combined with additional pattern elements of the Optical Proximity Correction generates huge data volumes which reduce correspondingly the throughput of conventional single e-beam pattern generators. On the other hand the achievable line edge roughness when using sensitive chemically amplified resists does not fulfill the future requirements. The application of less sensitive resists may provide an improved roughness, however on account of throughput, as well. To overcome this challenge a proton multi-beam pattern generator is developed [1]. Starting with a highly parallel broad beam, an aperture-plate is used to generate thousands of separate spot beams. These beams pass through a blanking-plate unit, based on a CMOS device for de-multiplexing the writing data and equipped with electrodes placed around the apertures switching the beams "on" or "off", dependent on the desired pattern. The beam array is demagnified by a 200x reduction optics and the exposure of the entire substrate is done by a continuous moving stage. One major challenge is the fabrication of the required high aspect deflection electrodes and their connection to the CMOS device. One approach is to combine a post-processed CMOS chip with a MEMS component containing the deflection electrodes and to realize the electrical connection of both by vertical integration techniques. For the evaluation and assessment of this considered scheme and fabrication technique, a proof-of-concept deflection unit has been realized and tested. Our design is based on the generation of the deflection electrodes in a silicon membrane by etching trenches and oxide filling afterwards. In a 5mm x 5mm area 43,000 apertures with the corresponding electrodes have been structured and wired individually or in

  4. A novel deflection shape function for rectangular capacitive micromachined ultrasonic transducer diaphragms

    Directory of Open Access Journals (Sweden)

    Zhou Zheng

    2015-09-01

    Full Text Available A highly accurate analytical deflection shape function that describes the deflection profiles of capacitive micromachined ultrasonic transducers (CMUTs with rectangular membranes under electrostatic pressure has been formulated. The rectangular diaphragms have a thickness range of 0.6–1.5 μm and a side length range of 100–1000 μm. The new deflection shape function generates deflection profiles that are in excellent agreement with finite element analysis (FEA results for a wide range of geometry dimensions and loading conditions. The deflection shape function is used to analyze membrane deformations and to calculate the capacitances between the deformed membranes and the fixed back plates. In 50 groups of random tests, compared with FEA results, the calculated capacitance values have a maximum deviation of 1.486% for rectangular membranes. The new analytical deflection function can provide designers with a simple way of gaining insight into the effects of designed parameters for CMUTs and other MEMS-based capacitive type sensors.

  5. Design of a 10 MeV normal conducting CW proton linac based on equidistant multi-gap CH cavities

    CERN Document Server

    Li, Zhihui

    2014-01-01

    The continue wave (CW) high current proton linac has wide applications as the front end of the high power proton machines. The low energy part is the most difficult one and there is no widely accepted solution yet. Based on the analysis of the focusing properties of the CW low energy proton linac, a 10 MeV low energy normal conducting proton linac based on equidistant seven-gap Cross-bar H-type (CH) cavities is proposed. The linac is composed of ten 7-gap CH cavities and the transverse focusing is maintained by the quadrupole doublets located between cavities. The total length of the linac is less than 6 meters and the average acceleration gradient is about 1.2 MeV/m. The electromagnetic properties of the cavities are investigated by Microwave Studio. At the nominal acceleration gradient the maximum surface electric field in the cavities is less than 1.3 times Kilpatrick limit, and the Ohmic loss of each cavity is less than 35 kW. The multi-particle beam dynamics simulations are performed with the help of the...

  6. Design of a 10 MeV normal conducting CW proton linac based on equidistant multi-gap CH cavities

    Science.gov (United States)

    Li, Zhi-Hui

    2015-09-01

    Continuous wave (CW) high current proton linacs have wide applications as the front end of high power proton machines. The low energy part of such a linac is the most difficult and there is currently no widely accepted solution. Based on the analysis of the focusing properties of the CW low energy proton linac, a 10 MeV low energy normal conducting proton linac based on equidistant seven-gap Cross-bar H-type (CH) cavities is proposed. The linac is composed of ten 7-gap CH cavities and the transverse focusing is maintained by quadrupole doublets located between the cavities. The total length of the linac is less than 6 meters and the average acceleration gradient is about 1.2 MeV/m. The electromagnetic properties of the cavities are investigated by Microwave Studio. At the nominal acceleration gradient the maximum surface electric field in the cavities is less than 1.3 times the Kilpatrick limit, and the Ohmic loss of each cavity is less than 35 kW. Multi-particle beam dynamics simulations are performed with Tracewin code, and the results show that the beam dynamics of the linac are quite stable, the linac has the capability to accelerate up to 30 mA beam with acceptable dynamics behavior. Supported by National Natural Science Foundation of China (11375122, 91126003)

  7. Laboratory experiments on arc deflection and instability

    Energy Technology Data Exchange (ETDEWEB)

    Zweben, S.; Karasik, M.

    2000-03-21

    This article describes experiments on arc deflection instability carried out during the past few years at the Princeton University Plasma Physics Laboratory (PPPL). The approach has been that of plasma physicists interested in arcs, but they believe these results may be useful to engineers who are responsible for controlling arc behavior in large electric steel furnaces.

  8. Design and simulation of 3½-cell superconducting gun cavity and beam dynamics studies of the SASE-FEL System at the Institute of Accelerator Technologies at Ankara University

    Science.gov (United States)

    Yildiz, H. Duran; Cakir, R.; Porsuk, D.

    2015-06-01

    Design and simulation of a superconducting gun cavity with 3½ cells have been studied in order to give the first push to the electron beam for the linear accelerating system at The Institute of Accelerator Technologies at Ankara University. Electrons are accelerated through the gun cavity with the help of the Radiofrequency power suppliers from cryogenic systems. Accelerating gradient should be as high as possible to accelerate electron beam inside the cavity. In this study, electron beam reaches to 9.17 MeV energy at the end of the gun cavity with the accelerating gradient; Ec=19.21 MV/m. 1.3 GHz gun cavity consists of three TESLA-like shaped cells while the special designed gun-cell includes a cathode plug. Optimized important beam parameters inside the gun cavity, average beam current 3 mA, transverse emittance 2.5 mm mrad, repetition rate 30 MHz and other parameters are obtained for the SASE-FEL System. The Superfish/Poisson program is used to design each cell of the superconducting cavity. Superconducting gun cavity and Radiofrequency properties are studied by utilizing 2D Superfish/Poisson, 3D Computer Simulation Technology Microwave Studio, and 3D Computer Simulation Technology Particle Studio. Superfish/Poisson is also used to optimize the geometry of the cavity cells to get the highest accelerating gradient. The behavior of the particles along the beamline is included in this study. ASTRA Code is used to track the particles.

  9. Deflection of uncooperative targets using laser ablation

    Science.gov (United States)

    Thiry, Nicolas; Vasile, Massimiliano

    2015-09-01

    Owing to their ability to move a target in space without requiring propellant, laser-based deflection methods have gained attention among the research community in the recent years. With laser ablation, the vaporized material is used to push the target itself allowing for a significant reduction in the mass requirement for a space mission. Specifically, this paper addresses two important issues which are thought to limit seriously the potential efficiency of a laser-deflection method: the impact of the tumbling motion of the target as well as the impact of the finite thickness of the material ablated in the case of a space debris. In this paper, we developed a steady-state analytical model based on energetic considerations in order to predict the efficiency range theoretically allowed by a laser deflection system in absence of the two aforementioned issues. A numerical model was then implemented to solve the transient heat equation in presence of vaporization and melting and account for the tumbling rate of the target. This model was also translated to the case where the target is a space debris by considering material properties of an aluminium 6061-T6 alloy and adapting at every time-step the size of the computational domain along with the recession speed of the interface in order to account for the finite thickness of the debris component. The comparison between the numerical results and the analytical predictions allow us to draw interesting conclusions regarding the momentum coupling achievable by a given laser deflection system both for asteroids and space debris in function of the flux, the rotation rate of the target and its material properties. In the last section of this paper, we show how a reasonably small spacecraft could deflect a 56m asteroid with a laser system requiring less than 5kW of input power.

  10. accelerating cavity

    CERN Multimedia

    On the inside of the cavity there is a layer of niobium. Operating at 4.2 degrees above absolute zero, the niobium is superconducting and carries an accelerating field of 6 million volts per metre with negligible losses. Each cavity has a surface of 6 m2. The niobium layer is only 1.2 microns thick, ten times thinner than a hair. Such a large area had never been coated to such a high accuracy. A speck of dust could ruin the performance of the whole cavity so the work had to be done in an extremely clean environment.

  11. Design and Performance of (Au,Yb)/ZnS/InSe/C Heterojunctions as Plasmon Resonators, Photodetectors and Microwave Cavities

    Science.gov (United States)

    Khusayfan, Najla M.; Khanfar, Hazem K.

    2016-12-01

    In this study, we concentrate on the design and characterization of the hybrid isotype (Au, Yb)/ZnS/InSe/C devices. The thin film devices that are prepared by using the vacuum deposition technique are characterized by means of x-ray diffraction, energy dispersive x-ray analysis, optical and dielectric spectroscopy, current-voltage characteristics and impedance spectroscopy techniques. The techniques allow determining the preferred crystallinity at the interfaces, the lattice match/mismatch ratios, the atomic compositions, the energy band gap shifts, the valence and conduction band offsets, the barrier heights at the Schottky shoulders (Au/ZnS and InSe/C) of the hybrid structure and the plasmonic interaction at the ZnS/InSe and (Au, Yb)/ZnS/InSe interfaces. The hybrid isotype device is found to exhibit photosensing features presented by a responsivity of ˜2.0 A/W, external quantum efficiencies (EQE) and internal quantum efficiencies (IQE) of 395% and 2493%, at basing voltage of 0.3 V, respectively. In addition, the dielectric spectra modeling reveals a plasmon-electron interaction of resonance frequencies in the range of 0.31-5.26 GHz and drift mobility of ˜212 cm2/Vs and 106 cm2/Vs for the Au/ZnS/InSe and Yb/ZnS/InSe, respectively. Moreover, the impedance spectroscopy studies confirm the correctness of the dielectric modeling nominating the Yb/ZnS/InSe/C devices as photodetectors, plasmon resonators and microwave cavities.

  12. Design and Performance of (Au,Yb)/ZnS/InSe/C Heterojunctions as Plasmon Resonators, Photodetectors and Microwave Cavities

    Science.gov (United States)

    Khusayfan, Najla M.; Khanfar, Hazem K.

    2017-03-01

    In this study, we concentrate on the design and characterization of the hybrid isotype (Au, Yb)/ZnS/InSe/C devices. The thin film devices that are prepared by using the vacuum deposition technique are characterized by means of x-ray diffraction, energy dispersive x-ray analysis, optical and dielectric spectroscopy, current-voltage characteristics and impedance spectroscopy techniques. The techniques allow determining the preferred crystallinity at the interfaces, the lattice match/mismatch ratios, the atomic compositions, the energy band gap shifts, the valence and conduction band offsets, the barrier heights at the Schottky shoulders (Au/ZnS and InSe/C) of the hybrid structure and the plasmonic interaction at the ZnS/InSe and (Au, Yb)/ZnS/InSe interfaces. The hybrid isotype device is found to exhibit photosensing features presented by a responsivity of ˜2.0 A/W, external quantum efficiencies (EQE) and internal quantum efficiencies (IQE) of 395% and 2493%, at basing voltage of 0.3 V, respectively. In addition, the dielectric spectra modeling reveals a plasmon-electron interaction of resonance frequencies in the range of 0.31-5.26 GHz and drift mobility of ˜212 cm2/Vs and 106 cm2/Vs for the Au/ZnS/InSe and Yb/ZnS/InSe, respectively. Moreover, the impedance spectroscopy studies confirm the correctness of the dielectric modeling nominating the Yb/ZnS/InSe/C devices as photodetectors, plasmon resonators and microwave cavities.

  13. Gain chip design, power scaling and intra-cavity frequency doubling with LBO of optically pumped red-emitting AlGaInP-VECSELs

    Science.gov (United States)

    Kahle, Hermann; Mateo, Cherry M. N.; Brauch, Uwe; Bek, Roman; Schwarzbäck, Thomas; Jetter, Michael; Graf, Thomas; Michler, Peter

    2016-03-01

    The wide range of applications in biophotonics, television or projectors, spectroscopy and lithography made the optically-pumped semiconductor (OPS) vertical external cavity surface-emitting lasers (VECSELs) an important category of power scalable lasers. The possibility of bandgap engineering, inserting frequency selective and converting elements into the open laser cavity and laser emission in the fundamental Gaussian mode leads to ongoing growth of the area of applications for tuneable laser sources. We present an AlGaInP-VECSEL system with a multi quantum well structure consisting of compressively strained GaInP quantum wells in an AlxGa1-xInP separate confinement heterostructure with an emission wavelength around 665 nm. The VECSEL chip with its n-λ cavity is pumped by a 532nm Nd:YAG laser under an angle to the normal incidence of 50°. In comparison, a gain chip design for high absorption values at pump wavelengths around 640nm with the use of quantum dot layers as active material is also presented. Frequency doubling is now realized with an antireflection coated lithium borate crystal, while a birefringent filter, placed inside the laser cavity under Brewster's angle, is used for frequency tuning. Further, power-scaling methods like in-well pumping as well as embedding the active region of a VECSEL between two transparent ic heaspreaders are under investigation.

  14. Opto-mechanical design of a buckling cavity in a novel high-performance outside-plant robust field installable single-mode fibre connector

    Science.gov (United States)

    Ebraert, Evert; Van Erps, Jürgen; Beri, Stefano; Watté, Jan; Thienpont, Hugo

    2014-05-01

    Fibre-to-the-home (FTTH) networks provide an ideal means to reach the goal the European Union has set to provide 50 % of the households with a broadband connection faster than 100 Mb/s. Deployment of FTTH networks, which is still costly today, could be significantly boosted by novel ferrule-less connectors which don't require highly skilled personnel and allow installation in the field. We propose a ferrule-less connector in which two single-mode fibres (SMFs) are aligned and maintain physical contact by ensuring that at least one fibre is in a buckled state. To this end, we design a cavity in which a fibre can buckle in a controlled way. Using finite element analysis simulations to investigate the shape of the formed buckle for various buckling cavity lengths, we show that it can be accurately approximated by a cosine function. In addition, the optical performance of a buckled SMF is investigated by bending loss calculations and simulations. We show a good agreement between the analytical and the simulated bending loss results for a G.652 fibre at a wavelength of 1550 nm. Buckling cavity lengths smaller than 20 mm should be avoided to keep the optical bending loss due to buckling below 0.1 dB. In this case the cavity height should at least be 2 mm to avoid mechanical confinement of the fibre.

  15. Deflecting Disinformation about Climate Change

    Science.gov (United States)

    Oreskes, N.

    2006-12-01

    A study by the Pew Center in the summer of 2006 showed that only 41 per cent of Americans have views consistent with the scientific facts about global warming. Nearly half of all Americans believe that there is "no solid" evidence of global warming, or that if warming is happening it can be attributed to natural variability. And an ABC/Time poll showed that two-thirds of Americans think that "there is a lot of disagreement among scientists" as to whether or not global warming is occurring. Scientists are apt to attribute such public misunderstandings to scientific illiteracy, and to think that the remedy is better communication. But public confusion over climate science is the result—at least in part--of organized campaigns designed to create confusion. The goal has been to create an impression of scientific disagreement, and thereby delay political action. This is a tactic that was previously employed in efforts to deny the reality of acid rain, the human role in ozone depletion, and the link between tobacco and cancer, in some cases by the same individuals who now deny the reality of global warming. In short, there is a pattern of which scientists need to be aware. Good faith efforts to explain the science are likely to fail in the face of bad-faith efforts to misrepresent it.

  16. Observation of Femtosecond Bunch Length Using a Transverse Deflecting Structure

    Energy Technology Data Exchange (ETDEWEB)

    Huning, M.; Bolzmann, A.; Schlarb, H.; /DESY; Frisch, J.; McCormick, D.; Ross, M.; Smith, T.; /SLAC; Rossbach, J.; /Hamburg U.

    2005-12-14

    The design of the VUV-FEL at DESY demands bunch lengths in the order of 50 fs and below. For the diagnostic of such very short bunches a transverse deflecting RF structure (LOLA) has been installed which streaks the beam according to the longitudinal distribution. Tests in the VUV-FEL yielded a rich substructure of the bunches. The most pronounced peak in the has a rms length of approximately 50 fs during FEL operation and below 20 fs FWHM at maximum compression. Depending on the transverse focusing a resolution well below 50 fs was achieved.

  17. Optofluidic Fabry-Pérot Micro-Cavities Comprising Curved Surfaces for Homogeneous Liquid Refractometry—Design, Simulation, and Experimental Performance Assessment

    OpenAIRE

    2016-01-01

    In the scope of miniaturized optical sensors for liquid refractometry, this work details the design, numerical simulation, and experimental characterization of a Fabry-Pérot resonator consisting of two deeply-etched silicon cylindrical mirrors with a micro-tube in between holding the liquid analyte under study. The curved surfaces of the tube and the cylindrical mirrors provide three-dimensional light confinement and enable achieving stability for the cavity illuminated by a Gaussian beam inp...

  18. Large deflection and rotation of Timoshenko beams with frictional end supports under three-point bending

    Science.gov (United States)

    Li, Dao-Kui; Li, Xian-Fang

    2016-08-01

    Three-point bending of a beam is studied based on the Timoshenko beam theory. Large deflection and large rotation of a beam resting on simple supports with friction are calculated for a concentrated force acting at the midspan. Using the Lagrangian kinematic relations, a system of non-linear differential equations are obtained for a prismatic shear-deformable Timoshenko beam. Exact solutions for the deflection, horizontal displacement, and rotation of cross-section are derived analytically. Two deflections of small and large scale exist under three-point bending. The solutions corresponding to linearized model coincide with the well-known solutions to the classical Timoshenko beams. Numerical calculations are carried out to show the effect of the important parameters such as shear rigidity of the beam and the coefficient of friction at the contact position between the beam and supports on the deflection. The load-deflection curves are graphically presented. A comparison of large deflections and large rotations with their classical counterparts and with experimental data is made. The obtained results are useful in safety design of linear and non-linear beams subject to three-point bending.

  19. UWB Wind Turbine Blade Deflection Sensing for Wind Energy Cost Reduction.

    Science.gov (United States)

    Zhang, Shuai; Jensen, Tobias Lindstrøm; Franek, Ondrej; Eggers, Patrick C F; Olesen, Kim; Byskov, Claus; Pedersen, Gert Frølund

    2015-08-12

    A new application of utilizing ultra-wideband (UWB) technology to sense wind turbine blade deflections is introduced in this paper for wind energy cost reduction. The lower UWB band of 3.1-5.3 GHz is applied. On each blade, there will be one UWB blade deflection sensing system, which consists of two UWB antennas at the blade root and one UWB antenna at the blade tip. The detailed topology and challenges of this deflection sensing system are addressed. Due to the complexity of the problem, this paper will first realize the on-blade UWB radio link in the simplest case, where the tip antenna is situated outside (and on the surface of) a blade tip. To investigate this case, full-blade time-domain measurements are designed and conducted under different deflections. The detailed measurement setups and results are provided. If the root and tip antenna locations are properly selected, the first pulse is always of sufficient quality for accurate estimations under different deflections. The measured results reveal that the blade tip-root distance and blade deflection can be accurately estimated in the complicated and lossy wireless channels around a wind turbine blade. Some future research topics on this application are listed finally.

  20. X-Band Crab Cavities for the CLIC Beam Delivery System

    Energy Technology Data Exchange (ETDEWEB)

    Burt, G.; Ambattu, P.K.; Dexter, A.C.; Abram, T.; /Cockcroft Inst. Accel. Sci. Tech. /Lancaster U.; Dolgashev, V.; Tantawi, S.; /SLAC; Jones, R.M.; /Cockcroft Inst. Accel. Sci. Tech. /Manchester U.

    2011-11-22

    The CLIC machine incorporates a 20 mrad crossing angle at the IP to aid the extraction of spent beams. In order to recover the luminosity lost through the crossing angle a crab cavity is proposed to rotate the bunches prior to collision. The crab cavity is chosen to have the same frequency as the main linac (11.9942 GHz) as a compromise between size, phase stability requirements and beam loading. It is proposed to use a HE11 mode travelling wave structure as the CLIC crab cavity in order to minimise beam loading and mode separation. The position of the crab cavity close to the final focus enhances the effect of transverse wake-fields so effective wake-field damping is required. A damped detuned structure is proposed to suppress and de-cohere the wake-field hence reducing their effect. Design considerations for the CLIC crab cavity will be discussed as well as the proposed high power testing of these structures at SLAC. Design of a crab cavity for CLIC is underway at the Cockcroft Institute in collaboration with SLAC. This effort draws on a large degree of synergy with the ILC crab cavity developed at the Cockcroft Institute and other deflecting structure development at SLAC. A study of phase and amplitude variations in the cavity suggests that the tolerances are very tight and require a 'beyond state of the art' LLRF control system. A study of cavity geometry and its effect on the cavity fields has been performed using Microwave studio. This study has suggested that for our cavity an iris radius between 4-5 mm is optimum with an iris thickness of 2-3 mm based on group velocity and peak fields. A study of the cavity wakefields show that the single bunch wakes are unlikely to be a problem but the short bunch spacing may cause the multi-bunch wakefields to be an issue. This will require some of the modes to be damped strongly so that the wake is damped significantly before any following bunch arrives. Various methods of damping have been investigated and

  1. X-Band Crab Cavities for the CLIC Beam Delivery System

    Energy Technology Data Exchange (ETDEWEB)

    Burt, G.; Ambattu, P.K.; Dexter, A.C.; Abram, T.; /Cockcroft Inst. Accel. Sci. Tech. /Lancaster U.; Dolgashev, V.; Tantawi, S.; /SLAC; Jones, R.M.; /Cockcroft Inst. Accel. Sci. Tech. /Manchester U.

    2011-11-22

    The CLIC machine incorporates a 20 mrad crossing angle at the IP to aid the extraction of spent beams. In order to recover the luminosity lost through the crossing angle a crab cavity is proposed to rotate the bunches prior to collision. The crab cavity is chosen to have the same frequency as the main linac (11.9942 GHz) as a compromise between size, phase stability requirements and beam loading. It is proposed to use a HE11 mode travelling wave structure as the CLIC crab cavity in order to minimise beam loading and mode separation. The position of the crab cavity close to the final focus enhances the effect of transverse wake-fields so effective wake-field damping is required. A damped detuned structure is proposed to suppress and de-cohere the wake-field hence reducing their effect. Design considerations for the CLIC crab cavity will be discussed as well as the proposed high power testing of these structures at SLAC. Design of a crab cavity for CLIC is underway at the Cockcroft Institute in collaboration with SLAC. This effort draws on a large degree of synergy with the ILC crab cavity developed at the Cockcroft Institute and other deflecting structure development at SLAC. A study of phase and amplitude variations in the cavity suggests that the tolerances are very tight and require a 'beyond state of the art' LLRF control system. A study of cavity geometry and its effect on the cavity fields has been performed using Microwave studio. This study has suggested that for our cavity an iris radius between 4-5 mm is optimum with an iris thickness of 2-3 mm based on group velocity and peak fields. A study of the cavity wakefields show that the single bunch wakes are unlikely to be a problem but the short bunch spacing may cause the multi-bunch wakefields to be an issue. This will require some of the modes to be damped strongly so that the wake is damped significantly before any following bunch arrives. Various methods of damping have been investigated and

  2. radiofrequency cavity

    CERN Multimedia

    1988-01-01

    The pulse of a particle accelerator. 128 of these radio frequency cavities were positioned around CERN's 27-kilometre LEP ring to accelerate electrons and positrons. The acceleration was produced by microwave electric oscillations at 352 MHz. The electrons and positrons were grouped into bunches, like beads on a string, and the copper sphere at the top stored the microwave energy between the passage of individual bunches. This made for valuable energy savings as it reduced the heat generated in the cavity.

  3. Effect of deflecting ring on noise generated by outdoor set of a split-unit air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Junwei; Ding, Guoliang [Institute of Refrigeration and Cryogenics, Shanghai JiaoTong University, Shanghai 200030 (China)

    2006-05-15

    In order to analyze the influence of the deflecting ring on the noise generated by the outdoor set of a split-unit air conditioner, the flow field in the outdoor set is simulated with the CFD software STAR-CD, the relative turbulent intensities are computed and the influence of the width and contoured duct of the deflecting ring on the noise generated by the outdoor set is analyzed. The results of computation and experiment show that there is an optimal width of the deflecting ring, corresponding to the minimum noise generated by the outdoor set. In addition, the influence of the contoured duct of the deflecting ring on the noise generated by the outdoor set is analyzed and a double contoured duct is designed. The results of computation and experiment verify that the deflecting ring with double contoured duct can improve the aerodynamic performance and reduce the noise generated by the outdoor set. (author)

  4. Design of a Novel Polarized Beam Splitter Based on a Two-Dimensional Photonic Crystal Resonator Cavity

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xuan; CHEN Shu-Wen; LIAO Qing-Hua; YU Tian-Bao; LIU Nian-Hua; HUANG Yong-Zhen

    2011-01-01

    @@ We propose and analyze a novel ultra-compact polarization beam splitter based on a resonator cavity in a two-dimensional photonic crystal.The two polarizations can be separated efficientlyby the strong coupling between the microcavities and the waveguides occurring around the resonant frequency of the cavities.The transmittance of two polarized light around 1.55 iim can be more than 98.6%, and the size of the device is less than 15 μm x 13μm,so these features will play an important role in future integrated optical circuits.

  5. The Effect of Cavity Design on Fracture Resistance and Failure Pattern in Monolithic Zirconia Partial Coverage Restorations - An In vitro Study

    Science.gov (United States)

    Harsha, Madhavareddy Sri; Babu, Mandava Ramesh; Leneena, Gudugunta; Krishna, Tejavath Sai; Divya, G

    2017-01-01

    Introduction Cavity preparations of posterior teeth have been frequently associated with decreased fracture strength of the teeth. Choosing the correct indirect restoration and the cavity design when restoring the posterior teeth i.e., premolars was difficult as it involves aesthetic, biomechanical and anatomical considerations. Aim To evaluate the fracture resistance and failure pattern of three different cavity designs restored with monolithic zirconia. Materials and Methods Human maxillary premolars atraumatically extracted for orthodontic reasons were chosen. A total of 40 teeth were selected and divided into four groups (n=10). Group I-Sound teeth (control with no preparation). Group II-MOD Inlay, Group III-Partial Onlay, Group IV-Complete Onlay. Restorations were fabricated with monolithic partially sintered zirconia CAD (SAGEMAX- NexxZr). All the 30 samples were cemented using Multilink Automix (Ivoclar) and subjected to fracture resistance testing using Universal Testing Machine (UTM) (Instron) with a steel ball of 3.5 mm diameter at crosshead speed of 0.5 mm/minute. Stereomicroscope was used to evaluate the modes of failure of the fractured specimen. Fracture resistance was tested using parametric one way ANOVA test, unpaired t-test and Tukey test. Fracture patterns were assessed using non-parametric Chi-square test. Results Group IV (Complete Onlay) presented highest fracture resistance and showed statistical significant difference. Group II (MOD Inlay) and Group III (Partial Onlay) showed significantly lower values than the Group I (Sound teeth). However, Groups I, II and III presented no significant difference from each other. Coming to the modes of failure, Group II (MOD Inlay) and Group III (Partial Onlay) presented mixed type of failures; Group IV (Complete Onlay) demonstrated 70% Type I failures. Conclusion Of the three cavity designs evaluated, Complete Onlay had shown a significant increase in the fracture resistance than the Sound teeth. PMID

  6. Simultaneous Optical Measurements of Axial and Tangential Steady-State Blade Deflections

    Science.gov (United States)

    Kurkov, Anatole P.; Dhadwal, Harbans S.

    1999-01-01

    Currently, the majority of fiber-optic blade instrumentation is being designed and manufactured by aircraft-engine companies for their own use. The most commonly employed probe for optical blade deflection measurements is the spot probe. One of its characteristics is that the incident spot on a blade is not fixed relative to the blade, but changes depending on the blade deformation associated with centrifugal and aerodynamic loading. While there are geometrically more complicated optical probe designs in use by different engine companies, this paper offers an alternate solution derived from a probe-mount design feature that allows one to change the probe axial position until the incident spot contacts either a leading or a trailing edge. By tracing the axial position of either blade edge one is essentially extending the deflection measurement to two dimensions, axial and tangential. The blade deflection measurements were obtained during a wind tunnel test of a fan prototype.

  7. Wakefield Damping for the CLIC Crab Cavity

    Energy Technology Data Exchange (ETDEWEB)

    Ambattu, P.K.; Burt, G.; Dexter, A.C.; Carter, R.G.; /Cockcroft Inst. Accel. Sci. Tech. /Lancaster U.; Khan, V.; Jones, R.M.; /Cockcroft Inst. Accel. Sci. Tech. /Manchester U.; Dolgashev, V.; /SLAC

    2011-12-01

    A crab cavity is required in the CLIC to allow effective head-on collision of bunches at the IP. A high operating frequency is preferred as the deflection voltage required for a given rotation angle and the RF phase tolerance for a crab cavity are inversely proportional to the operating frequency. The short bunch spacing of the CLIC scheme and the high sensitivity of the crab cavity to dipole kicks demand very high damping of the inter-bunch wakes, the major contributor to the luminosity loss of colliding bunches. This paper investigates the nature of the wakefields in the CLIC crab cavity and the possibility of using various damping schemes to suppress them effectively.

  8. Dark matter prospects in deflected mirage mediation

    Energy Technology Data Exchange (ETDEWEB)

    Holmes, Michael; Nelson, Brent D., E-mail: holmes.mi@neu.edu, E-mail: b.nelson@neu.edu [Department of Physics, Northeastern University, Boston, MA 02115 (United States)

    2009-07-01

    The recently introduced deflected mirage mediation (DMM) model is a string-motivated paradigm in which all three of the major supersymmetry-breaking transmission mechanisms are operative. We begin a systematic exploration of the parameter space of this rich model context, paying special attention to the pattern of gaugino masses which arise. In this work we focus on the dark matter phenomenology of the DMM model as such signals are the least influenced by the model-dependent scalar masses. We find that a large portion of the parameter space in which the three mediation mechanisms have a similar effective mass scale of 1 TeV or less will be probed by future direct and indirect detection experiments. Distinguishing deflected mirage mediation from the mirage model without gauge mediation will prove difficult without collider input, though we indicate how gamma ray signals may provide an opportunity for distinguishing between the two paradigms.

  9. Surface effects on large deflection of nanowires

    Institute of Scientific and Technical Information of China (English)

    杨帆

    2015-01-01

    Surface effects play an important role in the mechanical behavior of nanosized structural elements owing to the increased ratio of surface area to volume. The surface effects on the large deflection of nanowires were considered. Both geometric nonlinearity in finite deformation and surface effects at nanoscale were taken into account to analyze the bending of nanowires subjected to a concentrated force. For simply supported beams and clamped-clamped beams, the influence of surface effects and geometric nonlinearity were discussed in detail. It is found that both surface effects and geometric nonlinearity tend to decrease the deflection of bending nanowires and thus increase the effective elastic modulus of nanowires. Surface effects yield the size dependent behavior of nanowires.

  10. Optical forces through guided light deflections

    DEFF Research Database (Denmark)

    Palima, Darwin; Bañas, Andrew Rafael; Vizsnyiczai, Gaszton;

    2013-01-01

    Optical trapping and manipulation typically relies on shaping focused light to control the optical force, usually on spherical objects. However, one can also shape the object to control the light deflection arising from the light-matter interaction and, hence, achieve desired optomechanical effects....... In this work we look into the object shaping aspect and its potential for controlled optical manipulation. Using a simple bent waveguide as example, our numerical simulations show that the guided deflection of light efficiently converts incident light momentum into optical force with one order...... show that the force on the waveguide exceeds the combined forces on spherical trapping handles. Furthermore, it shows that static illumination can exert a constant force on a moving structure, unlike the position-dependent forces from harmonic potentials in conventional trapping....

  11. Deflection analysis of rectangular spatial coverage truss

    Directory of Open Access Journals (Sweden)

    M.N. Kirsanov

    2015-02-01

    Full Text Available An elastic spatial statically determinate truss of regular type, simulating the rectangular in plan coverage was considered. In the plane of the base the truss has two axes of symmetry. Four support structures (spherical hinge, cylindrical hinge and two vertical rods are located at its corners. An analytic solution was found for forces in the rods of the truss. Using the Maxwell-Mohr’s formula, the dependence of the deflection of the center was discovered in the truss under the influence of the concentrated force. There are five parameters of the problem in this formula: three linear dimensions, and the numbers of hinges on its lateral sides. To determine the desired patterns by means of the computer mathematics system Maple the recursion task by two parameters was solved. It was shown that dependence of the deflection on the number of panels and height of the truss detects a minimum, allowing optimizing the size of the structure.

  12. Deflection of proton beams by crystal miscut surface

    CERN Document Server

    Babaev, A A; Dabagov, S B

    2014-01-01

    First computer experiment results on proton beam deflection by the crystal miscut surface are presented. The phenomenology of proton channeling and quasichanneling has been applied to describe new features of the beam deflection. The analysis predicts efficient beam deflection by the acute crystal end due to repelling miscut potential.

  13. Deflection rheoevolution of lithosphere under subduction

    Institute of Scientific and Technical Information of China (English)

    韩玉英; 王维襄

    1997-01-01

    Along the continental margin, the tectonic system consisting of trench, island arc, back arc basin and outer rise is often known as a convergent transitional belt between the oceanic lithosphere and the continental litho-sphere. The occurrence, development and activity of trench and outer rise bear closely on the underthrusting process of the oceanic lithosphere. A generalized analytical theory of deflection rheoevolution of lithosphere under subduction is established, and solutions with universal significance have been obtained.

  14. Design and Applications of In-Cavity Pulse Shaping by Spectral Sculpturing in Mode-Locked Fibre Lasers

    Directory of Open Access Journals (Sweden)

    Sonia Boscolo

    2015-11-01

    Full Text Available We review our recent progress on the realisation of pulse shaping in passively-mode-locked fibre lasers by inclusion of an amplitude and/or phase spectral filter into the laser cavity. We numerically show that depending on the amplitude transfer function of the in-cavity filter, various regimes of advanced waveform generation can be achieved, including ones featuring parabolic-, flat-top- and triangular-profiled pulses. An application of this approach using a flat-top spectral filter is shown to achieve the direct generation of high-quality sinc-shaped optical Nyquist pulses with a widely tunable bandwidth from the laser oscillator. We also present the operation of an ultrafast fibre laser in which conventional soliton, dispersion-managed soliton (stretched-pulse and dissipative soliton mode-locking regimes can be selectively and reliably targeted by adaptively changing the dispersion profile and bandwidth programmed on an in-cavity programmable filter. The results demonstrate the strong potential of an in-cavity spectral pulse shaper for achieving a high degree of control over the dynamics and output of mode-locked fibre lasers.

  15. The Superconducting TESLA Cavities

    CERN Document Server

    Aune, B.; Bloess, D.; Bonin, B.; Bosotti, A.; Champion, M.; Crawford, C.; Deppe, G.; Dwersteg, B.; Edwards, D.A.; Edwards, H.T.; Ferrario, M.; Fouaidy, M.; Gall, P-D.; Gamp, A.; Gössel, A.; Graber, J.; Hubert, D.; Hüning, M.; Juillard, M.; Junquera, T.; Kaiser, H.; Kreps, G.; Kuchnir, M.; Lange, R.; Leenen, M.; Liepe, M.; Lilje, L.; Matheisen, A.; Möller, W-D.; Mosnier, A.; Padamsee, H.; Pagani, C.; Pekeler, M.; Peters, H-B.; Peters, O.; Proch, D.; Rehlich, K.; Reschke, D.; Safa, H.; Schilcher, T.; Schmüser, P.; Sekutowicz, J.; Simrock, S.; Singer, W.; Tigner, M.; Trines, D.; Twarowski, K.; Weichert, G.; Weisend, J.; Wojtkiewicz, J.; Wolff, S.; Zapfe, K.

    2000-01-01

    The conceptional design of the proposed linear electron-positron colliderTESLA is based on 9-cell 1.3 GHz superconducting niobium cavities with anaccelerating gradient of Eacc >= 25 MV/m at a quality factor Q0 > 5E+9. Thedesign goal for the cavities of the TESLA Test Facility (TTF) linac was set tothe more moderate value of Eacc >= 15 MV/m. In a first series of 27industrially produced TTF cavities the average gradient at Q0 = 5E+9 wasmeasured to be 20.1 +- 6.2 MV/m, excluding a few cavities suffering fromserious fabrication or material defects. In the second production of 24 TTFcavities additional quality control measures were introduced, in particular aneddy-current scan to eliminate niobium sheets with foreign material inclusionsand stringent prescriptions for carrying out the electron-beam welds. Theaverage gradient of these cavities at Q0 = 5E+9 amounts to 25.0 +- 3.2 MV/mwith the exception of one cavity suffering from a weld defect. Hence only amoderate improvement in production and preparation technique...

  16. [Pliability and deflection of diagnostic catheters].

    Science.gov (United States)

    Pelyhe, Liza; Bognár, Eszter

    2014-09-28

    The cardiac catheter is an intravascular catheter, which is introduced or implanted into the heart for diagnostic or therapeutic reasons. The catheters may break or king during their introduction and/or removal. The aim of the authors was to study the pliability of two catheters with the same material but different diameters according to the Food and Drug Administration's recommendation. The bending points, diameter decrease, deflection, and their correlation and dependence on the distance from the tip, as well as the influence of the initial diameter of the catheters were determined. The bending of catheters was performed on 9 bending points (120-280 mm from the tip by 20 mm) on 16 gauges with different radius (10-2.5 mm by 0.5 mm). A linear dependency between the diameter decrease and deflection was observed, which was independent from the placement of the measurement in both catheters examined. The larger initial diameter had significant (p = 0.05) greater diameter decrease than the smaller, but the curves characteristic of the diameter decrease and deflection were similar. The applied method seems to be useful for the examination of weak points of cardiac catheters.

  17. DESIGNING FEATURES OF POWER OPTICAL UNITS FOR TECHNOLOGICAL EQUIPMENT

    Directory of Open Access Journals (Sweden)

    M. Y. Afanasiev

    2016-03-01

    Full Text Available This paper considers the question of an optical unit designing for transmitting power laser radiation through an optical fiber. The aim of this work is designing a simple construction unit with minimized reflection losses. The source of radiation in the optical unit described below is an ultraviolet laser with diode pumping. We present the general functioning scheme and designing features for the three main parts: laser beam deflecting system, laser beam dump and optical unit control system. The described laser beam deflection system is composed of a moving flat mirror and a spherical scattering mirror. Comparative analysis of the production technology for such mirrors was carried out, and, as a result, the decision was made to produce both mirrors of 99.99 % pure molybdenum without coating. A moving mirror deflects laser emission from a source through a fiber or deflects it on a spherical mirror and into the laser beam dump, moreover, switching from one position to another occurs almost immediately. It is shown that a scattering mirror is necessary, otherwise, the absorbing surface of the beam dump is being worn out irregularly. The laser beam dump is an open conical cavity, in which the conical element with its spire turned to the emission source is placed. Special microgeometry of the internal surface of the beam dump is suggested for the better absorption effect. An optical unit control system consists of a laser beam deflection system, laser temperature sensor, deflection system solenoid temperature sensor, and deflection mirror position sensor. The signal processing algorithm for signals coming from the sensors to the controller is described. The optical unit will be used in special technological equipment.

  18. Design of a stacked diode array pumped Nd:YAG laser with a truncated compound parabolic concentrator and a diffusive optical cavity

    CERN Document Server

    Lee, S M; Yun, M J; Cha, B H; Lee, J M

    1999-01-01

    We designed and analyzed a new Nd:YAG laser which employs a combination of a truncated compound parabolic concentrator (CPC) and a diffusive optical pump cavity for pumping with a stacked diode array. A design code based on a ray-tracing algorithm was developed to analyze the Nd:YAG laser system. The optimum truncated CPC profile was determined from analyses of the dependences of the pump-beam distribution and the total absorbed power in the laser crystal upon the acceptance angle and the slit width of the CPC. In addition, the analyses show the importance of the acceptance angle in designing an efficient laser system with a truncated CPC. Using conservative design parameters, the design code predicted a Nd:YAG laser output of 130 W with a corresponding optical slope efficiency of 44%.

  19. 裁板锯偏转机构运动关系的反求设计与仿真%Reverse Design and Simulation of the Motion Relationship of the Deflection Mechanism of Board Cutting Saws

    Institute of Scientific and Technical Information of China (English)

    程朋乐; 谭月胜; 许亚东

    2011-01-01

    针对裁板锯锯片偏转系统运动关系复杂不易于单片机编程的问题,提出了应用反求设计开发模式求出连杆与丝杠系统的伸长量X和与之对应锯片偏转角度θ之间的函数关系。从采用Lagrange插值仿真得到的系统仿真曲线可知,四次多项式传递函数可以满足运动关系的精度要求,采用Matlab仿真最终确定二者之间的关系为一次函数。通过实验得出当偏转角为10°和35°时计算得到的直线误差最小,据此设计的裁板锯MJ6130Z已经批量生产。%In view of the problem that complicated motion relationship of the blade deflection system of board cutting saws makes MPU programming difficult,the function relation between the extension volume of the connecting rod and screw rod system and the correspo

  20. Profiling compact toroid plasma density on CTIX with laser deflection

    Science.gov (United States)

    Brockington, Samuel Joseph Erwin

    A laser deflectometer measures line-integrated plasma density gradient using laser diodes and amplified point detectors. A laser passing through an optically thin plasma is refracted by an amount proportional to the line-integrated electron density gradient. I have designed, installed, and operated a deflection diagnostic for the Compact Toroid Injection Experiment (CTIX), a plasma rail gun which can create compact toroid (CT) plasmas of controllable density and velocity. The diagnostic design and motivation are discussed, as well as three experiments performed with deflectometry. Thus, my thesis consists of the design of the deflectometer diagnostic, a comparison of its accuracy to interferometer density measurements, and finally a survey of compact toroid density profiles in two dimensions conducted with an array of detectors.

  1. High power RF system for transverse deflecting structure XFEL TDS INJ

    Science.gov (United States)

    Volobuev, E. N.; Zavadtsev, A. A.; Zavadtsev, D. A.; Smirnov, A. J.; Sobenin, N. P.; Churanov, D. V.

    2016-09-01

    The high power RF system (HPRF) is designed for RF feeding of the transverse deflecting structure of the transverse deflecting system XFEL TDS System INJ of the European X-ray Free Electron Laser. The HPRF system includes klystron, waveguide ceramic windows, directional couplers, waveguide vacuum units, spark detector and waveguide line. Operating frequency is 2997.2 MHz. Peak input power is up to 3 MW. The HPRF system has been developed, manufactured and assembled in the XFEL Injector building. The total length of the waveguide line is 55 m from the klystron at the -5 floor to the transverse deflecting structure at the -7 floor. All designed RF parameters have been obtained experimentally at low RF power level.

  2. Design of Synthesized DBRs for Long-Wavelength InP-Based Vertical-Cavity Surface-Emitting Lasers

    Institute of Scientific and Technical Information of China (English)

    HUANG Zhan-Chao; WU Hui-Zhen

    2004-01-01

    @@ We report applications of a metallic film and a phase matching layer (PML) to increase the reflectivity of the cavity mirror in a long-wavelength InP-based vertical-cavity surface-emitting laser (VCSEL). The synthesis of the InGaAsP/InP distributed-Bragg reflector (DBR) with an Au fllm and the InP PML leads to the decrease of periods of the DBR multilayer stacks from 33 to 20 while keeping the reflectivity of the structure over 99%.The reflectivity over the whole forbidden band is significantly increased and become flatter compared to the bare DBR. The use of smaller DBR periods in a long wavelength VCSEL makes the epitaxial growth well controllable,decrease of the heat resistance, and decrease of the in-series electrical resistance of the devices. This can improve the reliability of the VCSEL growth and possibly cut down the cost of VCSEL devices.

  3. Single and Coupled Nanobeam Cavities

    DEFF Research Database (Denmark)

    Ivinskaya, Aliaksandra; Lavrinenko, Andrei; Shyroki, Dzmitry M.

    2013-01-01

    for analysis and design of photonic crystal devices, such as 2D ring resonators for filters, single and coupled nanobeam cavities, birefringence in photonic crystal cavities, threshold analysis in photonic crystal lasers, gap solitons in photonic crystals, novel photonic atolls, dynamic characteristics...

  4. Design of the R.T. CH-Cavity and Perspectives for a New GSI Proton Linac

    CERN Document Server

    Li, Z

    2004-01-01

    The CH-Structure has been studied at the IAP Frankfurt and at GSI for several years. Compared with the IH structure (H110-mode), the CH structure (H210-mode) can work at higher frequency (700 MHz) and can accelerate ions to higher energy (up to 150 AMeV). Detailed Microwave Studio (MWS) simulations were performed for this structure. Since a multi-gap cavity can be approximated as a quasi-periodic structure, it is possible to analyze one βλ/2-cell at an energy corresponding to the cavity center. Additionally, a reduced copper conductivity of 85% was assumed. Geometry variations with respect to rf frequency and shunt impedance can be performed rapidly by that method in the first stage of optimization. Effective shunt impedances from 100 MΩ/m down to 25 MΩ/m were obtained for the energy range from 5 AMeV to 150 AMeV by this method. The rf frequency was 350 MHz up to 70 MeV and 700 MHz above. A systematic analysis of the influence of the cell number in long CH cavities on the...

  5. Large deflection of flexible tapered functionally graded beam

    Institute of Scientific and Technical Information of China (English)

    A.R.Davoodinik; G.H.Rahimi

    2011-01-01

    In this paper the semi-analytical analyses of the flexible cantilever tapered functionally graded beam under combined inclined end loading and intermediate loading are studied.In order to derive the fully non-linear equations governing the non-linear deformation,a curvilinear coordinate system is introduced.A general non-linear second order differential equation that governs the shape of a deflected beam is derived based on the geometric nonlinearities,infinitesimal local displacements and local rotation concepts with remarkable physical properties of functionally graded materials.The solutions obtained from semi-analytical methods are numerically compared with the existing elliptic integral solution for the case of a flexible uniform cantilever functionally graded beam.The effects of taper ratio,inclined end load angle and material property gradient on large deflection of the beam are evaluated.The Adomian decomposition method will be useful toward the design of tapered functionally graded compliant mechanisms driven by smart actuators.

  6. System for deflection measurements of floating dry docks

    Science.gov (United States)

    Gorbachev, Alexey A.; Pantyushin, Anton V.; Serikova, Mariya G.; Korotaev, Valery V.; Timofeev, Aleksandr N.

    2015-05-01

    In this paper we introduce a system for deflection measurement of floating dry docks. The system contains two measurement channels observing opposite directions of the dock. It also includes set of reference marks, an industrial computer and a display. Each channel contains CMOS camera with long focal-length lens. Reference marks are implemented as IR LED arrays with 940 nm working wavelength for better performance within bad weather conditions (e.g. fog, rain, high humidity etc.). In the paper we demonstrate results of an analysis of different optical schemes for coupling the oppositely directed channels of the measurement unit and show that the scheme with two image sensors with separated lenses is an optimal option, because it allows usage of nonequidistant location of reference marks and demonstrates the least value of parasitic shift caused by rotations of the measuring unit. The developed system was tested both on specially-designed setup and in real infrastructure of a floating dry dock. The conducted tests proved that a measuring error of the system is smaller than +/- 1.5 mm within the measurement range of +/- 150 mm when deflection of 100 m dock is measured. Obtained results showed that the system demonstrates an ability to work in a harsh environment including poor weather conditions.

  7. Characterisation of a Mechanical Deflection Sensor

    CSIR Research Space (South Africa)

    Miyambo, M

    2012-10-01

    Full Text Available ). REFERENCES Snyman, I.M. and Reinecke, J.D. 2006. Measuring the impulse from an explosive charge, Ballistics Symposium South Africa, Denel-OTB, Bredasdorp, 15?16 Aug 2006. Miyambo, M.E. and Pandelani, T. 2012. The Mechanical Deflection Sensor Test... Mechanical Defl ection Sensor M MIYAMBO AND T PANDELANI CSIR Defence, Peace, Safety and Security, PO Box 395, Pretoria, South Africa, 0001 Email: mmiyambo@csir.co.za ? www.csir.co.za INTRODUCTION The CSIR Defence, Peace, Safety and Security (DPSS...

  8. A Design of Constant Temperature Heating Circuit for a Resonant Cavity%一种谐振腔体的恒温加热电路设计

    Institute of Scientific and Technical Information of China (English)

    钦华

    2015-01-01

    For resonant cavity method is used to analyze cigarette density and humidity detection process,the stability of the resonant frequency accuracy of the test is very important.In this paper,a design scheme of con-stant temperature heating circuit for a resonant cavity in microwave density and humidity detector is presented, first introduces the measuring principle and architecture of the circuit,and then introduces the design and im-plementation,final y,experiments show that the design can meet the microwave detector testing requirements for measuring accuracy and stability.%对于利用谐振腔法对烟支进行湿密度检测过程中,谐振频率的稳定对测试精度至关重要。该文提出了一种微波密度湿度检测仪中谐振腔体恒温加热电路的设计方案,先介绍了该电路构成和原理,然后介绍了电路设计与实现,最后通过实验表明该电路可以满足微波密度湿度检测仪对测量精度和稳定性的要求。

  9. A Bridge Deflection Monitoring System Based on CCD

    Directory of Open Access Journals (Sweden)

    Baohua Shan

    2016-01-01

    Full Text Available For long-term monitoring of the midspan deflection of Songjiazhuang cloverleaf junction on 309 national roads in Zibo city, this paper proposes Zhang’s calibration-based DIC deflection monitoring method. CCD cameras are used to track the change of targets’ position, Zhang’s calibration algorithm is introduced to acquire the intrinsic and extrinsic parameters of CCD cameras, and the DIC method is combined with Zhang’s calibration algorithm to measure bridge deflection. The comparative test between Zhang’s calibration and scale calibration is conducted in lab, and experimental results indicate that the proposed method has higher precision. According to the deflection monitoring scheme, the deflection monitoring software for Songjiazhuang cloverleaf junction is developed by MATLAB, and a 4-channel CCD deflection monitoring system for Songjiazhuang cloverleaf junction is integrated in this paper. This deflection monitoring system includes functions such as image preview, simultaneous collection, camera calibration, deflection display, and data storage. In situ deflection curves show a consistent trend; this suggests that the proposed method is reliable and is suitable for the long-term monitoring of bridge deflection.

  10. Comparison between Deflection and Vibration Characteristics of Rectangular and Trapezoidal profile Microcantilevers

    Directory of Open Access Journals (Sweden)

    Booun Bang

    2009-04-01

    Full Text Available Arrays of microcantilevers are increasingly being used as physical, biological, and chemical sensors in various applications. To improve the sensitivity of microcantilever sensors, this study analyses and compares the deflection and vibration characteristics of rectangular and trapezoidal profile microcantilevers. Three models of each profile are investigated. The cantilevers are analyzed for maximum deflection, fundamental resonant frequency and maximum stress. The surface stress is modelled as in-plane tensile force applied on the top edge of the microcantilevers. A commercial finite element analysis software ANSYS is used to analyze the designs. Results show paddled trapezoidal profile microcantilevers have better sensitivity.

  11. Converse Piezoelectric Effect Induced Transverse Deflection of a Free-Standing ZnO Microbelt

    KAUST Repository

    Hu, Youfan

    2009-07-08

    We demonstrate the first electric field induced transverse deflection of a single-crystal, free-standing ZnO microbelt as a result of converse piezoelectric effect. For a microbelt growing along the c-axis, a shear stress in the a-c plane can be induced when an electric field E is applied along the a-axis of the wurtzite structure. As amplified by the large aspect ratio of the microbelt that grows along the c-axis, the strain localized near the root can be detected via the transverse deflection perpendicular to the ZnO microbelt. After an experimental approach was carefully designed and possible artifacts were ruled out, the experimentally observed degree of deflection of the microbelt agrees well with the theoretically expected result. The device demonstrated has potential applications as transverse actuators/sensors/switches and electric field induced mechanical deflectors. © 2009 American Chemical Society.

  12. Deflection and Vibration Control of Laminated Plates Using Extension and Shear Actuated Fiber Composites

    Directory of Open Access Journals (Sweden)

    S. Raja

    2011-01-01

    Full Text Available The use of surface bonded and embedded piezoelectric composite actuators is examined through a numerical study. Modelling schemes are therefore developed by applying the isoparametric finite element approach to idealise extension-bending and shear-bending couplings due to piezoelectric actuations. A modal control based linear quadratic regulator is employed to perform the active vibration control studies. Influence of shear actuation direction and its width has been examined and interesting deflection patterns are noticed. The through width SAFC develops a constant deflection beyond its length along the laminated plate length. In contrast, segmented SAFC produces a moderate to linearly varying deflection pattern. MFC actuators have shown promising features in vibration control performances. Nevertheless, closed loop damping presents the efficiency of SAFC in the vibration control application. It is therefore envisaged that optimally actuated smart laminates can be designed using MFC and SAFC to efficiently counteract the disturbance forces.

  13. Systematic characterization of optical beam deflection measurement system for micro and nanomechanical systems

    NARCIS (Netherlands)

    Herfst, R.W.; Klop, W.A.; Eschen, M.; Dool, T.C. van den; Koster, N.B.; Sadeghian Marnani, H.

    2014-01-01

    Optical beam deflection (OBD) measurement method is very popular in various types of scanning probe microscopy (SPM) and micro/nanomechanical sensors to measure a mechanical motion. This paper reports the detail design and implementation of a very low drift (2 nm over 1000 s), high bandwidth (40 MHz

  14. Systematic characterization of optical beam deflection measurement system for micro and nanomechanical systems

    NARCIS (Netherlands)

    Herfst, R.W.; Klop, W.A.; Eschen, M.; Dool, T.C. van den; Koster, N.B.; Sadeghian Marnani, H.

    2014-01-01

    Optical beam deflection (OBD) measurement method is very popular in various types of scanning probe microscopy (SPM) and micro/nanomechanical sensors to measure a mechanical motion. This paper reports the detail design and implementation of a very low drift (2 nm over 1000 s), high bandwidth (40

  15. Beam deflection induced by E×B near a linear filament cathode

    Science.gov (United States)

    Zhang, Huashun; Jiang, Jiasheng

    2017-02-01

    Beam deflection induced by E×B near a linear filament cathode in a two grid electron gun is presented theoretically and experimentally. The experimental results are consistent with the calculation based on the theoretical equations. The influences upon performance and design of electron gun with linear filament cathode, which is used broadly in electrocurtain accelerators, are discussed in detail.

  16. Quantum atomic lithography via cross-cavity optical Stern-Gerlach setup

    Science.gov (United States)

    Máximo, C. E.; Batalhão, T. B.; Bachelard, R.; de Moraes Neto, G. D.; de Ponte, M. A.; Moussa, M. H. Y.

    2014-10-01

    We present a fully quantum scheme to perform 2D atomic lithography based on a cross-cavity optical Stern-Gerlach setup: an array of two mutually orthogonal cavities crossed by an atomic beam perpendicular to their optical axes, which is made to interact with two identical modes. After deriving an analytical solution for the atomic momentum distribution, we introduce a protocol allowing us to control the atomic deflection by manipulating the amplitudes and phases of the cavity field states.

  17. Wakefield calculation for superconducting TM110 cavity without azimuthal symmetry

    Energy Technology Data Exchange (ETDEWEB)

    Bellantoni, Leo; /Fermilab; Burt, Graeme; /Lancaster U.

    2006-08-01

    The 3.9GHz TM{sub 110} mode deflecting cavity developed at FNAL has many applications, including use as a longitudinal bunch profile diagnostic, and as a crab cavity candidate for the ILC. These applications involve beams with substantial time structure. For the 13-cell version intended for the bunch profile application, long-range wakes have been evaluated in the frequency domain and short-range wakes have been evaluated in the time domain. Higher-order interactions of the main field in the cavity with the beam have also been parameterized. Pedagogic derivations are included as appendices.

  18. Power coupler for the ILC crab cavity

    Energy Technology Data Exchange (ETDEWEB)

    Burt, G.; Dexter, A.; Jenkins, R.; /Lancaster U.; Beard, C.; Goudket, P.; McIntosh, P.A.; /Daresbury; Bellantoni, Leo; /Fermilab

    2007-06-01

    The ILC crab cavity will require the design of an appropriate power coupler. The beam-loading in dipole mode cavities is considerably more variable than accelerating cavities, hence simulations have been performed to establish the required external Q. Simulations of a suitable coupler were then performed and were verified using a normal conducting prototype with variable coupler tips.

  19. A Limited Deflection Routing Algorithm Based on Burst Loss Threshold in OBS Networks

    Institute of Scientific and Technical Information of China (English)

    WANG Ru-yan; LONG Ke-ping; WU Wei; YANG Xiao-long; ZHU Wei-le

    2005-01-01

    The deflection routing protocol is an effective contention resolution in Optical Burst Switching network. However, it can worsen loss performance of non-deflected burst on the deflection route. To improve the burst loss performance, a limited deflection routing scheme based on burst loss threshold is proposed to prevent injudicious deflection routing. By using threshold check function, it restrainedly allows the deflected burst to preemptive network resource, consequently, improve the QoS performance of non-deflected burst. Simulation results show that the scheme can efficiently prevent deflected burst contending with non-deflected burst on deflection route, and effectively improve the burst loss performance of entire networks.

  20. Deflection of elastic beam with SMA wires eccentrically inserted

    Science.gov (United States)

    Jamian, S.; Nik Mohamed, N. A.; Ihsan, A. K. A. Mohd; Ismail, A. E.; Nor, M. K. Mohd; Kamarudin, K. A.; Nor, N. H. Muhd

    2017-08-01

    This research is intended to investigate the ability of shape memory alloys (SMA), through its activation, in generating loads to control beam deflection. An elastic beam is formed by sandwiching eccentrically SMA wires between two elastic plates. SMA wires are activated by electrical current from the power supply. Laser displacement meter (LDM) is used to measures deflection of sample. Results show that the deflection of the beam is dependent on the temperature change. The temperature-deflection response also shows the existence of hysteresis.

  1. Photon deflection by a Coulomb field in noncommutative QED

    Energy Technology Data Exchange (ETDEWEB)

    Pires, C A de S [Departamento de FIsica, Universidade Federal da ParaIba, Caixa Postal 5008, 58059-970, Joao Pessoa, PB (Brazil)

    2004-12-01

    In noncommutative QED photons present self-interactions in the form of triple and quartic interactions. The triple interaction implies that, even though the photon is electrically neutral, it will deflect when in the presence of an electromagnetic field. If detected, such deflection would be undoubted evidence of noncommutative space-time. In this work we derive a general expression for the deflection of a photon by any electromagnetic field. As an application we consider the case of the deflection of a photon by an external static Coulomb field. (brief report)

  2. Photon deflection by a Coulomb field in noncommutative QED

    CERN Document Server

    De Pires, C A S

    2004-01-01

    In noncommutative QED photons present self-interactions in the form of triple and quartic interactions. The triple interaction implies that, even though the photon is electrically neutral, it will deflect when in the presence of an electromagnetic field. If detected, such deflection would be an undoubted signal of noncommutative space-time. In this work we derive the general expression for the deflection of a photon by any electromagnetic field. As an application we consider the case of the deflection of a photon by an external static Coulomb field.

  3. Design and numerical simulation of a high power capacity relativistic backward wave oscillator with an electron collection cavity

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiaoze; Ye, Hu; Zhang, Yuchuan; Song, Wei; Su, Jiancang; Zhang, Ligang; Tan, Weibing; Hu, Xianggang; Zhu, Xiaoxin; Shen, Zhiyuan; Zhang, Min [Science and Technology on High Power Microwave Laboratory, Northwest Institute of Nuclear Technology, Xi' an 710024 (China)

    2016-05-15

    A high power capacity relativistic backward wave oscillator with an electron collection cavity (ECC) placed at the downstream of the slow wave structure (SWS) is presented. The breakdown threshold is increased, and the density of seed electron is suppressed by preventing the secondary electron, plasma, and powder generated from the bombardment of spent electron beam on the surface of the collector drifting to the extractor and beam-wave interaction region. The maximum longitudinal electric field in the device is reduced through extension of the span between electron beam and slow wave structure and weakening the Cerenkov radiation. The conversion efficiency reaches up to 52% owing to enhanced transit time radiation taking place at the entrance of the ECC. The maximum longitudinal electric field is 1.1 MV/cm on the surface of SWSs when the output power is 7.3 GW and the power capacity improves significantly.

  4. The CEBAF Separator Cavity Resonance Control System

    CERN Document Server

    Wissmann, Mark J; Hovater, Curt; Plawski, Tomasz

    2005-01-01

    The CEBAF energy upgrade from 6 GeV to 12GeV will increase the range of beam energies available to the experimental halls. RF deflection cavities (separators) are used to direct the electron beam to the three experimental halls. Consequently with the increase in RF separator cavity gradient needed for the higher energies, RF power will also increase requiring the cavities to have active resonance control. At the 6 GeV energy, the cavities are tuned mechanically and then stabilized with Low Conductivity Water (LCW), which is maintained at constant temperature of 95o Fahrenheit. This is no longer feasible and an active resonance control system, that controls both water temperature and flow has been built. The system uses a commercial PLC with embedded PID controls to control water temperature and flow to the cavities. The system allows the operator to remotely adjust temperature/flow and consequently cavity resonance for the full range of beam energies. Ultimately closed loop control will be maintained by monit...

  5. Cavity magnomechanics

    Science.gov (United States)

    Zou, Chang-Ling; Zhang, Xufeng; Jiang, Liang; Tang, Hong

    2016-05-01

    Recently, cavity magnonics has attracted much attention for potential applications of coherent information transduction and hybrid quantum devices. The magnon is a collective spin wave excitation in ferromagnetic material. It is magnetically tunability, with long coherence time and non-reciprocical interaction with electro-magnetic fields. We report the coherent coupling between magnon, microwave photon and phonon. First, we demonstrate strong coupling and ultrastrong coupling between the magnon in YIG sphere and microwave photon in three-dimensional cavity. Then, based on the hybridized magnon-photon modes, we observe the triply resonant magnon-mcirowave photon-phonon coupling, where the ultrahigh-Q mechanical vibration of YIG sphere is dispersively coupled with the magnon via magnetostrictive interaction. We observe interesting phenomena, including electromagnetically induced transparency/absorption and parametric amplification. In particular, benefit from the large tunability of the magnon, we demonstrate a tunable microwave amplifier with gain as high as 30 dB. The single crystal YIG also has excellent optical properties, and thus provide a unique platform bridging MHz, GHz and THz information carriers. Finally, we present the latest progress towards coherent magnon to optical photon conversion.

  6. Access cavity preparation.

    Science.gov (United States)

    Adams, N; Tomson, P L

    2014-03-01

    Each stage of root canal treatment should be carried out to the highest possible standard. The access cavity is arguably the most important technical stage, as subsequent preparation of the root canal(s) can be severely comprised if this is not well executed. Inadequate access can lead to canals being left untreated, poorly disinfected, difficult to shape and obturate, and may ultimately lead to the failure of the treatment. This paper highlights common features in root canal anatomy and outlines basic principles for locating root canals and producing a good access cavity. It also explores each phase of the preparation in detail and offers suggestions of instruments that have been specifically designed to overcome potential difficulties in the process. Good access design and preparation will result in an operative environment which will facilitate cleaning, shaping and obturation of the root canal system in order to maximise success.

  7. Dealing with Uncertainties in Asteroid Deflection Demonstration Missions: NEOTwIST

    CERN Document Server

    Eggl, Siegfried; Cano, Juan L; Avila, Javier Martin; Drube, Line; Harris, Alan W; Falke, Albert; Johann, Ulrich; Engel, Kilian; Schwartz, Stephen R; Michel, Patrick

    2016-01-01

    Deflection missions to near-Earth asteroids will encounter non-negligible uncertainties in the physical and orbital parameters of the target object. In order to reliably assess future impact threat mitigation operations such uncertainties have to be quantified and incorporated into the mission design. The implementation of deflection demonstration missions offers the great opportunity to test our current understanding of deflection relevant uncertainties and their consequences, e.g., regarding kinetic impacts on asteroid surfaces. In this contribution, we discuss the role of uncertainties in the NEOTwIST asteroid deflection demonstration concept, a low-cost kinetic impactor design elaborated in the framework of the NEOShield project. The aim of NEOTwIST is to change the spin state of a known and well characterized near-Earth object, in this case the asteroid (25143) Itokawa. Fast events such as the production of the impact crater and ejecta are studied via cube-sat chasers and a flyby vehicle. Long term chang...

  8. Design of a re-entrant double-staggered ladder circuit for V-band coupled-cavity traveling-wave tubes

    Institute of Scientific and Technical Information of China (English)

    Liu Yang; Xu Jin; Lai Jian-Qiang; Xu Xiong; Shen Fei; Wei Yan-Yu; Huang Min-Zhi; Tang Tao; Gong Yu-Bin

    2012-01-01

    The re-entrant double-staggered ladder slow-wave structure is employed in a high-power V-band coupled-cavity traveling-wave tube.This structure has a wide bandwidth,a moderate interaction impedance,and excellent thermal dissipation properties,as well as easy fabrication.A well-matched waveguide coupler is proposed for the structure.Combining the design of attenuators,a full-scale three-dimensional circuit model for the V-band coupled-cavity travelingwave tube is constructed.The electromagnetic characteristics and the beam-wave interaction of this structure are investigated.The beam current is set to be 100 mA,and the cathode voltage is tuned from 16.8 kV to 15.8 kV.The calculation results show that this tube can produce a saturated average output power over 100 W with an instantaneous bandwidth greater than 1.25 GHz in the frequency ranging from 58 GHz to 62 GHz.The corresponding gain and electronic efficiency can reach over 32 dB and 6.5%,respectively.

  9. Optofluidic Fabry-Pérot Micro-Cavities Comprising Curved Surfaces for Homogeneous Liquid Refractometry—Design, Simulation, and Experimental Performance Assessment

    Directory of Open Access Journals (Sweden)

    Noha Gaber

    2016-04-01

    Full Text Available In the scope of miniaturized optical sensors for liquid refractometry, this work details the design, numerical simulation, and experimental characterization of a Fabry-Pérot resonator consisting of two deeply-etched silicon cylindrical mirrors with a micro-tube in between holding the liquid analyte under study. The curved surfaces of the tube and the cylindrical mirrors provide three-dimensional light confinement and enable achieving stability for the cavity illuminated by a Gaussian beam input. The resonant optofluidic cavity attains a high-quality factor (Q—over 2800—which is necessary for a sensitive refractometer, not only by providing a sharp interference spectrum peak that enables accurate tracing of the peak wavelengths shifts, but also by providing steep side peaks, which enables detection of refractive index changes by power level variations when operating at a fixed wavelength. The latter method can achieve refractometry without the need for spectroscopy tools, provided certain criteria explained in the details are met. By experimentally measuring mixtures of acetone-toluene with different ratios, refractive index variations of 0.0005 < Δn < 0.0022 could be detected, with sensitivity as high as 5500 μW/RIU.

  10. 微波组件设计中的腔体效应%Cavity effects in the design of microwave modules

    Institute of Scientific and Technical Information of China (English)

    韩军

    2011-01-01

    The problems of self-excitation and worsening of S-Parameter caused by structure of microwave active module always happen in the design of microwave circuits. Up to now, there ia no complete theory to support the design of cavity. This study presented a theoretical analysis of the cavity effect of microwave module, in which microwave was transferred by microstrip lines. The microwave module with microstrip lines was simulated by High Frequency Structure Simulator(HFSS). a powerful full-wave simulation tool. A microwave module of X-band was designed according to the results of simulation and measurements of S-Parameters. The measured results agree well with the simulated resulta.%微波有源模块因为腔体的原因造成自激和传输参数的恶化一直是微波电路设计的难点之一.目前没有完整的理论来支持微波有源电路模块的腔体设计.本文从理论上分析了以微带线作为主要微波传输载体的微波组件的腔体效应,借助电磁场仿真工具HFSS对装有微带电路的微波组件进行了仿真.根据仿真结果设计X波段微波组件,并对S参数进行了测试,测试结果与仿真结果吻合,证明该方法是有效的.

  11. Cavity enhanced atomic magnetometry

    OpenAIRE

    Herbert Crepaz; Li Yuan Ley; Rainer Dumke

    2015-01-01

    Atom sensing based on Faraday rotation is an indispensable method for precision measurements, universally suitable for both hot and cold atomic systems. Here we demonstrate an all-optical magnetometer where the optical cell for Faraday rotation spectroscopy is augmented with a low finesse cavity. Unlike in previous experiments, where specifically designed multipass cells had been employed, our scheme allows to use conventional, spherical vapour cells. Spherical shaped cells have the advantage...

  12. Teach Deflection Concepts with Hacksaw Blades and Rubber Bands

    Science.gov (United States)

    Roman, Harry T.

    2013-01-01

    Technology and engineering educators can use a simple hacksaw blade to help students learn about deflection, as that which occurs in a beam. Here the beam is fixed at one end and allowed to deflect in a manner that is easy to see and measure--the hacksaw blade represents a cantilever, an overhanging structure. This simple and very inexpensive…

  13. A numerical analysis of the influence of the cavitator’s deflection angle on flow features for a free moving supercavitated vehicle

    Institute of Scientific and Technical Information of China (English)

    陈鑫; 鲁传敬; 陈瑛; 曹嘉怡

    2014-01-01

    When a high-speed cavitated weapon moves under water, the flow properties are important issues for the sake of the trajectory predication and control. In this paper, a single-fluid multiphase flow method coupled with a natural cavitation model is proposed to numerically simulate the free moving phase of an underwater supercavitated vehicle under the action of the external thrust. The influence of the cavitator’s deflection angle ranging fromo-3 to3o on the cavity pattern, the hydrodynamics and the underwater trajectory is investigated. Based on computational results, several conclusions are qualitatively drawn by an analysis. The deflection angle has very little effect on the cavity pattern. When the deflection angle increases, the variation curves of the vertical linear velocity, the lift coefficient and the pitching moment coefficient become flatter. In the phase of the second natural cavitation, at a same time, the greater the deflection angle is, the lower the drag and the lift coefficients will be and the higher the pitching moment coefficient becomes. At the finishing time of the free moving phase, when the deflection angle lies in the small range ofoo-1-1, the position of the center of mass and the pitching angle of the vehicle are more close to each other. However, when the deflection angle is less thano-1 or greater than1o, the position of the center of mass and the pitching angle change greatly. If a proper deflection angle of the cavitator is adopted, the underwater vehicle can navigate in a pseudo-fixed depth.

  14. Design, construction, and testing of a large-cavity, 1-10 GHz Flygare-Balle spectrometer

    Science.gov (United States)

    Kukolich, Stephen G.; Sarkozy, Laszlo C.

    2011-09-01

    A large pulsed-beam, Fourier transform microwave spectrometer employing 48 in. diameter mirrors and 35″ (NHS-35) diffusion pump has been constructed at the University of Arizona. The Fabry-Perot-type cavity, using the large mirrors provides Q-values in the 15 000 to 40 000 range. Test spectra were obtained using transverse and coaxial injection of the pulsed-nozzle molecular beams. The measured molecular resonance linewidths were 8 kHz for the transverse injection and 2 kHz for coaxial molecular beam injection. Good signal to noise ratios were obtained for the test signals. Strong lines for butadiene iron tricarbonyl were seen with a single beam pulse (S/N = 5/1). Transitions were measured as low as 900 MHz and some previously unresolved hyperfine structure is now resolved for the butadiene iron tricarbonyl spectra. The spectrometer is operated using a personal computer with LABVIEW programs, with provisions for automatic frequency scanning. The extended, low-frequency range of this spectrometer should make it very useful for making measurements on significantly larger molecules and complexes than have been previously studied. The improved resolution, in the coaxial beam mode, will allow better resolution of hyperfine structure. The large diffusion pump allows a higher beam pulse frequency to compensate for the generally lower sensitivity at lower frequencies.

  15. Design and Simulation of a Fused Silica Space Cell Culture and Observation Cavity with Microfluidic and Temperature Controlling

    Directory of Open Access Journals (Sweden)

    Shangchun Fan

    2013-01-01

    Full Text Available We report a principle prototype of space animal cell perfusion culture and observation. Unlike previous work, our cell culture system cannot only realize microfluidic and temperature controlling, automatic observation, and recording but also meet an increasing cell culture at large scale operation and overcome shear force for animal cells. A key component in the system is ingenious structural fused silica cell culture cavity with the wedge-shaped connection. Finite volume method (FVM is applied to calculate its multipoint flow field, pressure field, axial velocity, tangential velocity, and radial velocity. In order to provide appropriate flow rate, temperature, and shear force for space animal cell culture, a closed-loop microfluidic circuit and proportional, integrating, and differentiation (PID algorithm are employed. This paper also illustrates system architecture and operating method of the principle prototype. The dynamic culture, autofocus observation, and recording of M763 cells are performed successfully within 72 h in the laboratory environment. This research can provide a reference for space flight mission that carries an apparatus with similar functions.

  16. Study on the causes and methods of influencing concrete deflection

    Science.gov (United States)

    Zhou, Ying; Zhou, Xiang; Tang, Jinyu

    2017-09-01

    Under the long-term effect of static load on reinforced concrete beam, the stiffness decreases and the deformation increases with time. Therefore, the calculation of deflection is more complicated. According to the domestic and foreign research results by experiment the flexural deflection of reinforced concrete, creep, age, the thickness of the protective layer, the relative slip, the combination of steel yielding factors of reinforced concrete deflection are summarized, analyzed the advantages and disadvantages of the traditional direct measurement of deflection, that by increasing the beam height, increasing the moment of inertia, ncrease prestressed reinforcement ratio, arching, reduce the load, and other measures to reduce the deflection of prestressed construction, improve the reliability of structure.

  17. Modeling and Simulating Dynamics of Missiles with Deflectable Nose Control

    Institute of Scientific and Technical Information of China (English)

    Gao Yuan; Gu Liangxian; Pan Lei

    2009-01-01

    This article investigates the dynamic characteristics of deflectable nose missiles with rotary single-channel control. After introduction of effective attack and sideslip angles as well as quasi-body coordinates based on the spin characteristics of the missile's body, an integrated rigid kinetic model of missile with deflectable nose control is set up in the quasi-body coordinates considering the interaction between the missile's nose and body by using rootless multi-rigid-body system dynamics and is linearized. Then an analysis with simulation is conducted to investigate the coupling characteristics between the channels, the influences of nose deflection on the body and the dynamic characteristics of missile's body. The results indicate that various channels of missiles with deflectable nose control are coupled cross-linked; the nose deflection tends to make the body move in the opposite direction and, finally, evidences the correctness and reasonability of the kinetic model proposed by this article.

  18. Optimized frequency dependent photothermal beam deflection spectroscopy

    Science.gov (United States)

    Korte, D.; Cabrera, H.; Toro, J.; Grima, P.; Leal, C.; Villabona, A.; Franko, M.

    2016-12-01

    In the letter the optimization of the experimental setup for photothermal beam deflection spectroscopy is performed by analyzing the influence of its geometrical parameters (detector and sample position, probe beam radius and its waist position etc) on the detected signal. Furthermore, the effects of the fluid’s thermo-optical properties, for optimized geometrical configuration, on the measurement sensitivity and uncertainty determination of sample thermal properties is also studied. The examined sample is a recently developed CuFeInTe3 material. It is seen from the obtained results, that it is a complex problem to choose the proper geometrical configuration as well as sensing fluid to enhance the sensitivity of the method. A signal enhancement is observed at low modulation frequencies by placing the sample in acetonitrile (ACN), while at high modulation frequencies the sensitivity is higher for measurements made in air. For both, detection in air and acetonitrile the determination of CuFeInTe3 thermal properties is performed. The determined values of thermal diffusivity and thermal conductivity are (0.048  ±  0.002)  ×  10-4 m2 s-1 and 4.6  ±  0.2 W m-1 K-1 and (0.056  ±  0.005)  ×  10-4 m2 s-1 and 4.8  ±  0.4 W m-1 K-1 for ACN and air, respectively. It is seen, that the determined values agree well within the range of their measurement uncertainties for both cases, although the measurement uncertainty is two times lower for the measurements in ACN providing more accurate results. The analysis is performed by the use of recently developed theoretical description based on the complex geometrical optics. It is also shown, how the presented work fits into the current status of photothermal beam deflection spectroscopy.

  19. Highly stable piezoelectrically tunable optical cavities

    CERN Document Server

    Möhle, Katharina; Döringshoff, Klaus; Nagel, Moritz; Peters, Achim

    2013-01-01

    We have implemented highly stable and tunable frequency references using optical high finesse cavities which incorporate a piezo actuator. As piezo material we used ceramic PZT, crystalline quartz, or PZN-PT single crystals. Lasers locked to these cavities show a relative frequency stability better than 1 x 10^{-14}, which is most likely not limited by the piezo actuators. The piezo cavities can be electrically tuned over more than one free spectral range (> 1.5 GHz) with only a minor decrease in frequency stability. Furthermore, we present a novel cavity design, where the piezo actuator is prestressed between the cavity spacer components. This design features a hermetically sealable intra cavity volume suitable for, e.g., cavity enhanced spectroscopy.

  20. Application of artificial neural networks to predict the deflections of reinforced concrete beams

    Science.gov (United States)

    Kaczmarek, Mateusz; Szymańska, Agnieszka

    2016-06-01

    Nonlinear structural mechanics should be taken into account in the practical design of reinforced concrete structures. Cracking is one of the major sources of nonlinearity. Description of deflection of reinforced concrete elements is a computational problem, mainly because of the difficulties in modelling the nonlinear stress-strain relationship of concrete and steel. In design practise, in accordance with technical rules (e.g., Eurocode 2), a simplified approach for reinforced concrete is used, but the results of simplified calculations differ from the results of experimental studies. Artificial neural network is a versatile modelling tool capable of making predictions of values that are difficult to obtain in numerical analysis. This paper describes the creation and operation of a neural network for making predictions of deflections of reinforced concrete beams at different load levels. In order to obtain a database of results, that is necessary for training and testing the neural network, a research on measurement of deflections in reinforced concrete beams was conducted by the authors in the Certified Research Laboratory of the Building Engineering Institute at Wrocław University of Science and Technology. The use of artificial neural networks is an innovation and an alternative to traditional methods of solving the problem of calculating the deflections of reinforced concrete elements. The results show the effectiveness of using artificial neural network for predicting the deflection of reinforced concrete beams, compared with the results of calculations conducted in accordance with Eurocode 2. The neural network model presented in this paper can acquire new data and be used for further analysis, with availability of more research results.

  1. LHC crab-cavity aspects and strategy

    Energy Technology Data Exchange (ETDEWEB)

    Calaga, R.; Tomas, R.; Zimmermann, F.

    2010-05-23

    The 3rd LHC Crab Cavity workshop (LHC-CC09) took place at CERN in October 2009. It reviewed the current status and identified a clear strategy towards a future crab-cavity implementation. Following the success of crab cavities in KEK-B and the strong potential for luminosity gain and leveling, CERN will pursue crab crossing for the LHC upgrade. We present a summary and outcome of the variousworkshop sessions which have led to the LHC crab-cavity strategy, covering topics like layout, cavity design, integration, machine protection, and a potential validation test in the SPS.

  2. Large-deflection statics analysis of active cardiac catheters through co-rotational modelling.

    Science.gov (United States)

    Peng Qi; Chen Qiu; Mehndiratta, Aadarsh; I-Ming Chen; Haoyong Yu

    2016-08-01

    This paper presents a co-rotational concept for large-deflection formulation of cardiac catheters. Using this approach, the catheter is first discretized with a number of equal length beam elements and nodes, and the rigid body motions of an individual beam element are separated from its deformations. Therefore, it is adequate for modelling arbitrarily large deflections of a catheter with linear elastic analysis at the local element level. A novel design of active cardiac catheter of 9 Fr in diameter at the beginning of the paper is proposed, which is based on the contra-rotating double helix patterns and is improved from the previous prototypes. The modelling section is followed by MATLAB simulations of various deflections when the catheter is exerted different types of loads. This proves the feasibility of the presented modelling approach. To the best knowledge of the authors, it is the first to utilize this methodology for large-deflection static analysis of the catheter, which will enable more accurate control of robot-assisted cardiac catheterization procedures. Future work would include further experimental validations.

  3. A load balancing bufferless deflection router for network-on-chip

    Science.gov (United States)

    Xiaofeng, Zhou; Zhangming, Zhu; Duan, Zhou

    2016-07-01

    The bufferless router emerges as an interesting option for cost-efficient in network-on-chip (NoC) design. However, the bufferless router only works well under low network load because deflection more easily occurs as the injection rate increases. In this paper, we propose a load balancing bufferless deflection router (LBBDR) for NoC that relieves the effect of deflection in bufferless NoC. The proposed LBBDR employs a balance toggle identifier in the source router to control the initial routing direction of X or Y for a flit in the network. Based on this mechanism, the flit is routed according to XY or YX routing in the network afterward. When two or more flits contend the same one desired output port a priority policy called nearer-first is used to address output ports allocation contention. Simulation results show that the proposed LBBDR yields an improvement of routing performance over the reported bufferless routing in the flit deflection rate, average packet latency and throughput by up to 13%, 10% and 6% respectively. The layout area and power consumption compared with the reported schemes are 12% and 7% less respectively. Project supported by the National Natural Science Foundation of China (Nos. 61474087, 61322405, 61376039).

  4. Asteroid Impact and Deflection Assessment mission: the Double Asteroid Redirection Test (DART)

    Science.gov (United States)

    Cheng, A.; Michel, P.

    2015-10-01

    The Asteroid Impact & Deflection Assessment (AIDA) mission will be the first space experiment to demonstrate asteroid impact hazard mitigation by using a kinetic impactor. AIDA is a joint ESA-NASA cooperative project, which includes the ESA Asteroid Impact Mission (AIM) rendezvous spacecraft and the NASA Double Asteroid Redirection Test (DART) mission. The AIDA target is the near-Earth binary asteroid 65803 Didymos, which will make an unusually close approach to Earth in October, 2022. The ~300-kg DART spacecraft is designed to impact the Didymos secondary at 6.5 km/s and demonstrate the ability to modify its trajectory through momentum transfer. The primary goals of AIDA are (i) to investigate the binary near-Earth asteroid (65803) Didymos, (ii) to demonstrate asteroid deflection by kinetic impact and to characterize the deflection. The primary DART objectives are to demonstrate a hypervelocity impact on the Didymos moon and to determine the resulting deflection from ground-based observatories. The DART impact on the Didymos secondary will cause a measurable change in the orbital period of the binary.

  5. TESLA superconducting RF cavity development

    Energy Technology Data Exchange (ETDEWEB)

    Koepke, K. [Fermi National Accelerator Lab., Batavia, IL (United States); TESLA Collaboration

    1995-05-01

    The TESLA collaboration has made steady progress since its first official meeting at Cornell in 1990. The infrastructure necessary to assemble and test superconducting rf cavities has been installed at the TESLA Test Facility (TTF) at DESY. 5-cell, 1.3 GHz cavities have been fabricated and have reached accelerating fields of 25 MV/m. Full sized 9-cell copper cavities of TESLA geometry have been measured to verify the higher order modes present and to evaluate HOM coupling designs. The design of the TESLA 9-cell cavity has been finalized and industry has started delivery. Two prototype 9-cell niobium cavities in their first tests have reached accelerating fields of 10 MV/m and 15 MV/m in a vertical dewar after high peak power (HPP) conditioning. The first 12 m TESLA cryomodule that will house 8 9-cell cavities is scheduled to be delivered in Spring 1995. A design report for the TTF is in progress. The TTF test linac is scheduled to be commissioned in 1996/1997. (orig.).

  6. Cavities/Tooth Decay

    Science.gov (United States)

    Cavities/tooth decay Overview By Mayo Clinic Staff Cavities are permanently damaged areas in the hard surface of your teeth ... into tiny openings or holes. Cavities, also called tooth decay or caries, are caused by a combination of ...

  7. Cavity enhanced atomic magnetometry

    CERN Document Server

    Crepaz, Herbert; Dumke, Rainer

    2015-01-01

    Atom sensing based on Faraday rotation is an indispensable method for precision measurements, universally suitable for both hot and cold atomic systems. Here we demonstrate an all-optical magnetometer where the optical cell for Faraday rotation spectroscopy is augmented with a low finesse cavity. Unlike in previous experiments, where specifically designed multipass cells had been employed, our scheme allows to use conventional, spherical vapour cells. Spherical shaped cells have the advantage that they can be effectively coated inside with a spin relaxation suppressing layer providing long spin coherence times without addition of a buffer gas. Cavity enhancement shows in an increase in optical polarization rotation and sensitivity compared to single-pass configurations.

  8. Cavity enhanced atomic magnetometry.

    Science.gov (United States)

    Crepaz, Herbert; Ley, Li Yuan; Dumke, Rainer

    2015-10-20

    Atom sensing based on Faraday rotation is an indispensable method for precision measurements, universally suitable for both hot and cold atomic systems. Here we demonstrate an all-optical magnetometer where the optical cell for Faraday rotation spectroscopy is augmented with a low finesse cavity. Unlike in previous experiments, where specifically designed multipass cells had been employed, our scheme allows to use conventional, spherical vapour cells. Spherical shaped cells have the advantage that they can be effectively coated inside with a spin relaxation suppressing layer providing long spin coherence times without addition of a buffer gas. Cavity enhancement shows in an increase in optical polarization rotation and sensitivity compared to single-pass configurations.

  9. Long term dynamics of the high luminosity Large Hadron Collider with crab cavities

    Science.gov (United States)

    Barranco García, J.; De Maria, R.; Grudiev, A.; Tomás García, R.; Appleby, R. B.; Brett, D. R.

    2016-10-01

    The High Luminosity upgrade of the Large Hadron Collider (HL-LHC) aims to achieve an integrated luminosity of 200 - 300 fb-1 per year, including the contribution from the upgrade of the injector chain. For the HL-LHC the larger crossing angle together with a smaller beta function at the collision point would result in more than 70% luminosity loss due to the incomplete geometric overlap of colliding bunches. To recover head-on collisions at the high-luminosity particle-physics detectors ATLAS and CMS and benefit from the very low β* provided by the Achromatic Telescopic Squeezing (ATS) optics, a local crab cavity scheme provides transverse kicks to the proton bunches. The tight space constraints at the location of these cavities leads to designs which are axially non-symmetric, giving rise to high order multipoles components of the main deflecting mode and, since these kicks are harmonic in time, we expand them in a series of multipoles in a similar fashion as is done for static field magnets. In this work we calculate, for the first time, the higher order multipoles and their impact on beam dynamics for three different crab cavity prototypes. Different approaches to calculate the multipoles are presented. Furthermore, we perform the first calculation of their impact on the long term stability of the machine using the concept of dynamic aperture.

  10. Heavy colored SUSY partners from deflected anomaly mediation

    CERN Document Server

    Wang, Fei; Yang, Jin Min; Zhang, Yang

    2015-01-01

    We propose a deflected anomaly mediation scenario from SUSY QCD which can lead to both positive and negative deflection parameters (there is a smooth transition between these two deflection parameter regions by adjusting certain couplings). Such a scenario can naturally give a SUSY spectrum in which all the colored sparticles are heavy while the sleptons are light. As a result, the discrepancy between the Brookheaven $g_\\mu-2$ experiment and LHC data can be reconciled in this scenario. We also find that the parameter space for explaining the $g_\\mu-2$ anomaly at $1\\sigma$ level can be fully covered by the future LUX-ZEPLIN 7.2 Ton experiment.

  11. Simulations of directed energy comet deflection

    Science.gov (United States)

    Zhang, Qicheng; Lubin, Philip M.; Hughes, Gary B.

    2016-09-01

    Earth-crossing asteroids and comets pose a long-term hazard to life and property on Earth. Schemes to mitigate the impact threat have been studied extensively but tend to focus on asteroid diversion while neglecting the possibility of a comet threat. Such schemes often demand physically intercepting the target by spacecraft, a task feasible only for targets identified decades in advance in a restricted range of orbits. A threatening comet is unlikely to satisfy these criteria and so necessitates a fundamentally different approach for diversion. Comets are naturally perturbed from purely gravitational trajectories through solar heating of their surfaces which activates sublimation-driven jets. Artificial heating of a comet, such as by a high-powered laser array in Earth orbit, may supplement natural heating by the Sun to purposefully manipulate its path to avoid an impact. The effectiveness of any particular laser array for a given comet depends on the comet's heating response which varies dramatically depending on factors including nucleus size, orbit and dynamical history. These factors are incorporated into a numerical orbital model using established models of nongravitational perturbations to evaluate the effectiveness and feasibility of using high-powered laser arrays in Earth orbit or on the ground to deflect a variety of comets. Simulation results suggest that orbital arrays of 500m and 10GW operating for 10 min=d over 1 yr may be adequate for mitigating impacts by comets up to 500m in diameter. Continuously operating ground-based arrays of 100m and 10GW may be similarly effective when appropriately located.

  12. Picoradian deflection measurement with an interferometric quasi-autocollimator using weak value amplification.

    Science.gov (United States)

    Turner, Matthew D; Hagedorn, Charles A; Schlamminger, Stephan; Gundlach, Jens H

    2011-04-15

    We present an "interferometric quasi-autocollimator" that employs weak value amplification to measure angular deflections of a target mirror. The device has been designed to be insensitive to all translations of the target. We present a conceptual explanation of the amplification effect used by the device. An implementation of the device demonstrates sensitivities better than 10 picoradians per root hertz between 10 and 200 Hz.

  13. Development of Experimental Device for Compression Load Deflection of Car Door Seals

    Institute of Scientific and Technical Information of China (English)

    赵建才; 朱训生; 万德安

    2003-01-01

    A new experimental device has been developed for analyzing compression load deflection of the door seal by using stereovision theory. Precision instruments of optical grating and force sensor are also integrated in this device. Force-displacement response characteristics of compression at varied speed can be controlled. Solid foundations for characteristic and structure as well as optimization design of the car door seal are elucidated.

  14. Toward Identifying Needed Investments in Modeling and Simulation Tools for NEO Deflection Planning

    Science.gov (United States)

    Adams, Robert B.

    2009-01-01

    Its time: a) To bring planetary scientists, deflection system investigators and vehicle designers together on the characterization/mitigation problem. b) To develop a comprehensive trade space of options. c) To trade options under a common set of assumptions and see what comparisons on effectiveness can be made. d) To explore the synergy that can be had with proposed scientific and exploration architectures while interest in NEO's are at an all time high.

  15. Geoid Height and Deflection of the Vertical Models

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Office of the National Geodetic Survey has produced a series of high-resolution gravimetric geoid models, hybrid geoid models, and associated deflection of the...

  16. Deflection measurements of LABAN canister sections in horizontal attitude

    Energy Technology Data Exchange (ETDEWEB)

    Wakeman, W.

    1985-01-08

    Deflection measurements made on the LABAN canister sections indicate that the apparent stiffness of its frames, with all the diagnostics experiments installed, is not significantly different from the stiffness of the bare frames.

  17. U.S. East-West Deflections (DEFLEC96)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This 2' surface deflection of the vertical grid for the conterminous United States is the DEFLEC96 model. The computationused about 1.8 million terrestrial and...

  18. U.S. North-South Deflections (DEFLEC96)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This 2' surface deflection of the vertical grid for the conterminous United States is the DEFLEC96 model. The computationused about 1.8 million terrestrial and...

  19. Hawaiian Islands North-South Deflections (DEFLEC96)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This 2' surface deflection of the vertical grid for the Principal Hawaiian Islands is the DEFLEC96 model. The computation used about 61,000 terrestrial and marine...

  20. Hawaiian Islands East-West Deflections (DEFLEC96)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This 2' surface deflection of the vertical grid for the Principal Hawaiian Islands is the DEFLEC96 model. The computation used about 61,000 terrestrial and marine...

  1. PR/VI North-South Deflections (DEFLEC96)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This 2' surface deflection of the vertical grid for Puerto Rico and the Virgin Islands is distributed as the DEFLEC96 model. The computation used about 26,000...

  2. Possible influences on bullet trajectory deflection in ballistic gelatine.

    Science.gov (United States)

    Riva, Fabiano; Kerkhoff, Wim; Bolck, Annabel; Mattijssen, Erwin J A T

    2017-02-01

    The influence of the distance to the top and bottom of a gelatine block and to bullet tracks from previously fired shots on a bullet's trajectory, when passing through ballistic gelatine, was studied. No significant difference in deflection was found when trajectories of 9mm Luger bullets, fired at a 3.5cm distance to the top and bottom of a gelatine block and to bullet tracks from previously fired shots, were compared to trajectories of bullets fired 7cm or more away from any of the aforementioned aspects. A surprisingly consistent 6.5° absolute deflection angle was found when these bullets passed through 22.5 to 23.5cm of ballistic gelatine. The projection angle, determined by the direction of the deflection, appeared to be random. The consistent absolute angle, in combination with the random projection angle, resulted in a cone-like deflection pattern.

  3. PR/VI East-West Deflections (DEFLEC96)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This 2' surface deflection of the vertical grid for Puerto Rico and the Virgin Islands is distributed as the DEFLEC96 model. The computation used about 26,000...

  4. 75 FR 12981 - Eligibility for Commercial Flats Failing Deflection

    Science.gov (United States)

    2010-03-18

    ... and June 2010. Retain current deflection standards for six more months and enlist the assistance of a Lean Six-Sigma group. Response to Comments The prices proposed in our December 2009 proposal...

  5. A simple analytical solution for predicting deflection of a hybrid FRP-aluminum modular space truss bridge

    Institute of Scientific and Technical Information of China (English)

    李飞; 张冬冬; 赵启林; 邓安仲

    2015-01-01

    A novel hybrid FRP-aluminum space truss was employed in a two-rut modular bridge superstructure, which is composed of standard structural units. The main objective of this work was to obtain a simple analytical solution that can conveniently predict the deflection of the proposed hybrid space truss bridge. The analytical formulae are expected to possess a straightforward format and simple calculation process. A simple description of the proposed bridge was introduced. The design formulae of the deflection were derived based on a simplified analytical plane truss model, which possessed hinge nodes and was subsequently simplified as two solid web beams during the theoretical derivation process. To validate the analytical model and formulae, numerical and experimental works were conducted and compared with the theoretical solutions. The results indicate that the analytical formulae provide higher deflection magnitudes with a difference of <1.5% compared with the experiments performed and <4.5% compared with the FE model used; the simplified plane truss is thus shown to be an effective analytical model for the derivation of deflection design formulae, which can conveniently calculate the deflection of the hybrid space truss bridge with satisfactory accuracy.

  6. Deflection and Rotation of CMEs from Active Region 11158

    Science.gov (United States)

    Kay, Christina; Gopalswamy, Nat; Xie, Hong; Yashiro, Seiji

    2017-06-01

    Between 13 and 16 February 2011, a series of coronal mass ejections (CMEs) erupted from multiple polarity inversion lines within active region 11158. For seven of these CMEs we employ the graduated cylindrical shell (GCS) flux rope model to determine the CME trajectory using both Solar Terrestrial Relations Observatory (STEREO) extreme ultraviolet (EUV) and coronagraph images. We then use the model called Forecasting a CME's Altered Trajectory (ForeCAT) for nonradial CME dynamics driven by magnetic forces to simulate the deflection and rotation of the seven CMEs. We find good agreement between ForeCAT results and reconstructed CME positions and orientations. The CME deflections range in magnitude between 10^{circ } and 30^{circ}. All CMEs are deflected to the north, but we find variations in the direction of the longitudinal deflection. The rotations range between 5^{circ} and 50^{circ} with both clockwise and counterclockwise rotations. Three of the CMEs begin with initial positions within 2^{circ} from one another. These three CMEs are all deflected primarily northward, with some minor eastward deflection, and rotate counterclockwise. Their final positions and orientations, however, differ by 20^{circ} and 30^{circ}, respectively. This variation in deflection and rotation results from differences in the CME expansion and radial propagation close to the Sun, as well as from the CME mass. Ultimately, only one of these seven CMEs yielded discernible in situ signatures near Earth, although the active region faced toward Earth throughout the eruptions. We suggest that the differences in the deflection and rotation of the CMEs can explain whether each CME impacted or missed Earth.

  7. Beam Dynamics Studies and the Design, Fabrication and Testing of Superconducting Radiofrequency Cavity for High Intensity Proton Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Saini, Arun [Univ. of Delhi, New Delhi (India)

    2012-03-01

    The application horizon of particle accelerators has been widening significantly in recent decades. Where large accelerators have traditionally been the tools of the trade for high-energy nuclear and particle physics, applications in the last decade have grown to include large-scale accelerators like synchrotron light sources and spallation neutron sources. Applications like generation of rare isotopes, transmutation of nuclear reactor waste, sub-critical nuclear power, generation of neutrino beams etc. are next area of investigation for accelerator scientific community all over the world. Such applications require high beam power in the range of few mega-watts (MW). One such high intensity proton beam facility is proposed at Fermilab, Batavia, US, named as Project-X. Project-X facility is based on H- linear accelerator (linac), which will operate in continuous wave (CW) mode and accelerate H- ion beam with average current of 1 mA from kinetic energy of 2.5 MeV to 3 GeV to deliver 3MW beam power. One of the most challenging tasks of the Project-X facility is to have a robust design of the CW linac which can provide high quality beam to several experiments simultaneously. Hence a careful design of linac is important to achieve this objective.

  8. Implications of resin-based composite (RBC) restoration on cuspal deflection and microleakage score in molar teeth: Placement protocol and restorative material.

    Science.gov (United States)

    McHugh, Lauren E J; Politi, Ioanna; Al-Fodeh, Rami S; Fleming, Garry J P

    2017-09-01

    To assess the cuspal deflection of standardised large mesio-occluso-distal (MOD) cavities in third molar teeth restored using conventional resin-based composite (RBC) or their bulk fill restorative counterparts compared with the unbound condition using a twin channel deflection measuring gauge. Following thermocycling, the cervical microleakage of the restored teeth was assessed to determine marginal integrity. Standardised MOD cavities were prepared in forty-eight sound third molar teeth and randomly allocated to six groups. Restorations were placed in conjunction with (and without) a universal bonding system and resin restorative materials were irradiated with a light-emitting-diode light-curing-unit. The dependent variable was the restoration protocol, eight oblique increments for conventional RBCs or two horizontal increments for the bulk fill resin restoratives. The cumulative buccal and palatal cuspal deflections from a twin channel deflection measuring gauge were summed, the restored teeth thermally fatigued, immersed in 0.2% basic fuchsin dye for 24h, sectioned and examined for cervical microleakage score. The one-way analysis of variance (ANOVA) identified third molar teeth restored using conventional RBC materials had significantly higher mean total cuspal deflection values compared with bulk fill resin restorative restoration (all presin restored teeth had significantly the lowest microleakage scores compared with Tetric EvoCeram Bulk Fill (bonded and non-bonded) teeth (all presin restoratives behave in a similar manner when used to restore standardised MOD cavities in third molar teeth. It would appear that light irradiation of individual conventional RBCs or bulk fill resin restoratives may be problematic such that material selection is vital in the absence of clinical data. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. A real-time, nonintrusive trace gas detector based on laser photothermal deflection

    Science.gov (United States)

    de Vries, H. S. M.; Dam, N.; van Lieshout, M. R.; Sikkens, C.; Harren, F. J. M.; Reuss, J.

    1995-09-01

    We present the layout and technical details of a trace gas monitor based on photothermal deflection. The operating principle of this instrument, i.e., the deflection of a (weak) probe laser beam by the thermal refractive index gradient induced by trace gas absorption of an intense pump laser beam, allows nonintrusive measurements with good space and time resolution. An intra-cavity CO2 laser is used as the pump beam and a red HeNe laser as the probe. The latter runs perpendicular to the pump beam to optimize spatial resolution. To increase sensitivity, the probe laser is incorporated in a multipass setup. The instrument is demonstrated by the localization of ethylene emission sites on a cherry tomato and by monitoring ammonia production due to nitrogen fixation by cyanobacteria. Both C2H4 and NH3 can be detected at the 1-3 ppb level, at a spatial resolution of 2 mm (along the pump laser)×0.6 mm (perpendicular to it), and a response time of 0.1 s (without background correction) or 15 s (including background correction). Sensitivity can be increased at the expense of spatial resolution, and vice versa. In principle, this instrument is applicable to all those gases possessing a characteristic (``fingerprint'') spectrum in the CO2 laser range. The great advantage of the photothermal deflection technique with respect to other trace gas detection schemes lies in the nonintrusive character of the measurements. There is no need to enclose the sample in a vessel or to suck large volumes of air into the detector; measurements can be performed in open air and in real time. This should prove especially useful where sticky (polar) gases, like H2O, NH3, CH3OH, etc., are to be detected quantitatively. Main applications include air quality monitoring, especially concerning dry deposition rate measurements using the eddy correlation technique, and the study of volatile metabolite emission of biological samples.

  10. Design and Experimental Research of Solar Blackbody Cavity Absorber%太阳能黑腔集热器的设计及实验研究

    Institute of Scientific and Technical Information of China (English)

    张晓晖; 姜伟娜; 徐鉴鉴

    2014-01-01

    在黑体概念的基础上,设计了1种新型太阳能腔体集热器,并进行了实验。新型太阳能腔体集热器利用黑腔的高吸收率、泡沫板的良好隔热性以及玻璃板营造的温室效应,使得集热器的整体热损失明显下降,从而提高了集热效率。测试结果表明:集热器内介质为水时,平均温升为15.1℃,最大温升为21℃,热效率最低为53%。各项热损失计算结果表明:黑腔辐射造成的热损失最大,反射热损失和对流热损失很小。新型太阳能腔体集热器结构紧凑,单位体积的有效吸热面积较平板太阳能集热器和真空管太阳能集热器大。%On the basis of traditional cavity absorber,a kind of new solar cavity-heat receiver is designed.With advantage of high absorptivity and good thermal insulation,the whole heat loss gets smaller and can obtain high thermal efficiency.The result of the experiment shows that the mean temperature rise is 15.1℃ and the highest temperature rise is 21℃ when water is filled,and the thermal efficiency is 53% under present situa-tion.The result of the thermal loss calculation indicates that radiation heat loss accounts for the most,while reflection heat loss and convection heat loss is small.The compact design has bigger effective heat absorbing area per volume than flat plate solar collector and evacuated tubular collector.

  11. Directed Energy Deflection Laboratory Measurements of Asteroids and Space Debris

    Science.gov (United States)

    Brashears, T.; Lubin, P. M.

    2016-12-01

    We report on laboratory studies of the effectiveness of directed energy planetary and space defense as a part of the DE-STAR (Directed Energy System for Targeting of Asteroids and exploRation) program. DE-STAR [1][5][6] and DE-STARLITE [2][5][6] are directed energy "stand-off" and "stand-on" programs, respectively. These systems consist of a modular array of kilowatt-class lasers powered by photovoltaics, and are capable of heating a spot on the surface of an asteroid to the point of vaporization. Mass ejection, as a plume of evaporated material, creates a reactionary thrust capable of diverting the asteroid's orbit. In a series of papers, we have developed a theoretical basis and described numerical simulations for determining the thrust produced by material evaporating from the surface of an asteroid [1][2][3][4][5][6]. In the DE-STAR concept, the asteroid itself is used as the deflection "propellant". This study presents results of experiments designed to measure the thrust created by evaporation from a laser directed energy spot. We constructed a vacuum chamber to simulate space conditions, and installed a torsion balance that holds an "asteroid" or a space debris sample. The sample is illuminated with a fiber array laser with flux levels up to 60 MW/m2 which allows us to simulate a mission level flux but on a small scale. We use a separate laser as well as a position sensitive centroid detector to readout the angular motion of the torsion balance and can thus determine the thrust. We compare the measured thrust to the models. Our theoretical models indicate a coupling coefficient well in excess of 100 µN/Woptical, though we assume a more conservative value of 80 µN/Woptical and then degrade this with an optical "encircled energy" efficiency of 0.75 to 60 µN/Woptical in our deflection modeling. Our measurements discussed here yield about 60 µN/Wabsorbed as a reasonable lower limit to the thrust per optical watt absorbed.

  12. Directed energy deflection laboratory measurements of common space based targets

    Science.gov (United States)

    Brashears, Travis; Lubin, Philip; Hughes, Gary B.; Meinhold, Peter; Batliner, Payton; Motta, Caio; Madajian, Jonathan; Mercer, Whitaker; Knowles, Patrick

    2016-09-01

    We report on laboratory studies of the effectiveness of directed energy planetary defense as a part of the DE-STAR (Directed Energy System for Targeting of Asteroids and exploRation) program. DE-STAR and DE-STARLITE are directed energy "stand-off" and "stand-on" programs, respectively. These systems consist of a modular array of kilowatt-class lasers powered by photovoltaics, and are capable of heating a spot on the surface of an asteroid to the point of vaporization. Mass ejection, as a plume of evaporated material, creates a reactionary thrust capable of diverting the asteroid's orbit. In a series of papers, we have developed a theoretical basis and described numerical simulations for determining the thrust produced by material evaporating from the surface of an asteroid. In the DESTAR concept, the asteroid itself is used as the deflection "propellant". This study presents results of experiments designed to measure the thrust created by evaporation from a laser directed energy spot. We constructed a vacuum chamber to simulate space conditions, and installed a torsion balance that holds a common space target sample. The sample is illuminated with a fiber array laser with flux levels up to 60 MW/m2 , which allows us to simulate a mission level flux but on a small scale. We use a separate laser as well as a position sensitive centroid detector to readout the angular motion of the torsion balance and can thus determine the thrust. We compare the measured thrust to the models. Our theoretical models indicate a coupling coefficient well in excess of 100 μN/Woptical, though we assume a more conservative value of 80 μN/Woptical and then degrade this with an optical "encircled energy" efficiency of 0.75 to 60 μN/Woptical in our deflection modeling. Our measurements discussed here yield about 45 μN/Wabsorbed as a reasonable lower limit to the thrust per optical watt absorbed. Results vary depending on the material tested and are limited to measurements of 1 axis, so

  13. Deflection measurement system for the hybrid iii six-year-old biofidelic abdomen.

    Science.gov (United States)

    Gregory, T Stan; Howes, Meghan K; Rouhana, Stephen W; Hardy, Warren N

    2012-01-01

    Motor vehicle collisions are the leading cause of death for children ages 5 to 14. Enhancement of child occupant protection is partly dependent on the ability to accurately assess the interaction of child-size occupants with restraint systems. Booster seat design and belt fit are evaluated using child anthropomorphic test devices, such as the Hybrid III 6-year-old dummy., A biofidelic abdomen for the Hybrid III 6-year-old dummy is being developed by the Ford Motor Company to enhance the dummy’s ability to assess injury risk and further quantify submarining risk by measuring abdominal deflection. A practical measurement system for the biofidelic abdominal insert has been developed and demonstrated for three dimensional determination of abdominal deflection. Quantification of insert deflection is achieved via differential signal measurement using electrodes mounted within a conductive medium. Signal amplitude is proportional to the distance between the electrodes. A microcontroller is used to calculate distances between ventral electrodes and a dorsal electrode in three dimensions. This system has been calibrated statically, and its performance demonstrated in a series of sled tests. Deflection measurements from the instrumented abdominal insert indicate performance differences between two booster seat designs, yielding an average peak anterior to posterior displacement of the abdomen of 1.0 ± 3.4 mm and 31.2 ± 7.2 mm for the seats, respectively. Implementation of a 6-year-old abdominal insert with the ability to evaluate submarining potential will likely help safety researchers further enhance booster seat design and interaction with vehicle restraint systems , and help to further understand child occupant injury risk in automobile collisions.

  14. Design of Si/SiO2 micropillar cavities for Purcell-enhanced single photon emission at 1.55 μm from InAs/InP quantum dots.

    Science.gov (United States)

    Song, Hai-Zhi; Takemoto, Kazuya; Miyazawa, Toshiyuki; Takatsu, Motomu; Iwamoto, Satoshi; Yamamoto, Tsuyoshi; Arakawa, Yasuhiko

    2013-09-01

    Numerical simulations were carried out on micropillar cavities consisting of Si/SiO2 distributed Bragg reflectors (DBRs) with an InP spacer layer. Owing to a large refractive index contrast of ~2 in DBRs, cavities with just 4/6.5 top/bottom DBR pairs that give a low pillar height (~4.5 μm), have noticeable Purcell-enhancement effect in the 1.55-μm band. With careful designs on cavities with diameters of ~2.30 μm, a quality factor of up to 3300, a nominal Purcell factor of up to 110, and an output efficiency of ~60% are obtainable. These results ensure improvement of operation frequency and enhancement of photon indistinguishability for 1.55-μm single photon sources based on InAs/InP quantum dots.

  15. Comet deflection by directed energy: a finite element analysis

    Science.gov (United States)

    Madajian, Jonathan; Griswold, Janelle; Gandra, Anush; Hughes, Gary B.; Zhang, Qicheng; Rupert, Nic; Lubin, Philip

    2016-09-01

    Comets and Asteroids are viable threats to our planet; if these space rocks are smaller than 25 meters, they burn up in the atmosphere, but if they are wider than 25 meters they can cause damage to the impact area. Anything more than one to two kilometers can have worldwide effects, furthermore a mile-wide asteroid travelling at 30,000 miles per hour has the energy equal to a megaton bomb and is very likely to wipe out most of the life on Earth. Residents near Chelyabinsk, Russia experienced the detrimental effects of a collision with a Near-Earth Asteroid (NEA) on 15 February 2013 as a 20 m object penetrated the atmosphere above that city. The effective yield from this object was approximately 1/2 Megaton TNT equivalent (Mt), or that of a large strategic warhead. The 1908 Tunguska event, also over Russia, is estimated to have had a yield of approximately 15 Mt and had the potential to kill millions of people had it come down over a large city1. In the face of such danger a planetary defense system is necessary and this paper proposes a design for such a system. DE-STAR (Directed Energy System for Targeting of Asteroids and exploRation) is a phased array laser system that can be used to oblate, deflect and de-spin asteroids and comets.

  16. GPS deflection monitoring of the West Gate Bridge

    Science.gov (United States)

    Raziq, Noor; Collier, Philip

    2007-05-01

    The achievable precision and relatively high sampling rates of currently available GPS receivers are well suited for monitoring the movements of long-span engineering structures where the amplitude of movements is often more than a few centimetres and the frequency of vibrations is low (below 10 Hz). However, engineering structures often offer non-ideal environments for GPS data collection due to high multipath interference and obstructions causing cycle slips in the GPS observations. Also, for many engineering structures such as bridge decks, vertical movements are more pronounced and more structurally critical than horizontal movements. Accuracy of GPS determined positions in the vertical direction is typically two to three times poorer than in the horizontal component. This paper describes the results of a GPS deflection monitoring trial on the West Gate Bridge in Melbourne, Australia. The results are compared to the estimated frequencies and movements from the design of the bridge and previous accelerometer campaigns. The frequency information derived from the GPS results is also compared to frequency data extracted from an accelerometer installed close to a GPS receiver. GPS results agree closely to the historical results and recent accelerometer trials for key modal frequencies. This indicates the suitability of GPS receivers to monitor engineering structures that exhibit smaller movements due to their stiffness and in environments not ideally suited to using GPS.

  17. Principle and Feasibility of Electric or Magnetic Field Deflection-Projection Based Rapid Prototyping Technique

    Institute of Scientific and Technical Information of China (English)

    张连洪; 李双义; 张宝峰; 熊晓明

    2003-01-01

    Rapid prototype manufacturing(RPM) is a new advanced manufacturing technology, which is based on the philosophy of materials increasing of lay by lay forming. Zero adventure rapid design/manufacturing can be realized with rapid prototypes of 3D CAD of products. Rapid prototyping has been an effective tool of R&D of new products. A novel rapid prototyping and manufacturing (RP&M) technique is brought forward. The principle of the process is to form layered sections and to make the prototype or part layer-by-layer by deflection-projection of electric charged powder granules passing through electric or magnetic field and by controllable line and field scan of the powder granule beam. The feasibility issue of the process is theoretically and experimentally investigated.It shows that deflection-projection of electric charged powder granules beam passing through electric field can be significant and feasible to the rapid prototyping technique.

  18. Evaluating Loading Deflection of Distraction Osteogenic Rib in a Rabbit Model.

    Science.gov (United States)

    Shen, Weimin; Tang, Chenlu; Yang, Junyi; Kong, Liangliang; Zhang, Xiaoying

    2016-10-01

    The treatment of patients with partially atrophic rib and rib defects requires an ideal arc of the rib that has adequate bone length and width. To design and assemble a distraction device with a strain gauge, we need to establish an animal model for testing it during rib distraction osteogenesis. Osteotomies were performed at the same position in the fifth rib in 8 rabbits. Customized distraction devices attached to strain gauges were used to distract the ribs. After a month of distraction and consolidation, loading deflection gauges were used, and specimens were examined histologically to record bone formation. Distraction osteogenesis was carried out successfully in all rabbits when the device used to distract the rib up to 4 cm. The device can be used for strain testing during rib distraction osteogenesis performed in a rabbit model. There was no significant difference in the loading deflection gauges of the bone between osteogenic and contralateral ribs. This animal model of costal distraction osteogenesis is successful.

  19. Study on precision processing of L-form ZnSe deflect prism

    Science.gov (United States)

    Ye, Sizhe; Hui, Changshun; Zhang, Hao; Lu, Yongbin

    2016-10-01

    As the core component of optical system of Roll-Pitch seekers, the L-form ZnSe deflect prism is directly affecting the imaging quality of optical. For L-form defect prism's complex polyhedron plane structure and the feature of CVD ZnSe polycrystalline material, this paper propose one processing of single point diamond fly-cutting, analyze the transformation calculation method of each plane's coordinate. A kind of special clamp which ensure that all working surface of prism could be cut by once clamping is designed. Base on parameters of turning for CVD ZnSe , the deflect prisms are been processed, the measure result of angle error is below 12", the surface error (rms) reach 0.022λ, which satisfies the demand of manufacturing accuracy. It provide effective processing methods for optical parts with complex space.

  20. Multi-beamlet investigation of the deflection compensation methods of SPIDER beamlets

    Energy Technology Data Exchange (ETDEWEB)

    Baltador, C., E-mail: carlo.baltador@igi.cnr.it; Veltri, P.; Agostinetti, P.; Chitarin, G.; Serianni, G. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete S.p.A), Corso Stati Uniti, 4, 35127 Padova (Italy)

    2016-02-15

    SPIDER (Source for Production of Ions of Deuterium Extracted from a Rf plasma) is an ion source test bed designed to extract and accelerate a negative ion current up to 40 A and 100 kV whose first beam is expected by the end of 2016. Two main effects perturb beamlet optics during the acceleration stage: space charge repulsion and the deflection induced by the permanent magnets (called co-extracted electron suppression magnets) embedded in the EG. The purpose of this work is to evaluate and compare benefits, collateral effects, and limitations of electrical and magnetic compensation methods for beamlet deflection. The study of these methods has been carried out by means of numerical modeling tools: multi-beamlet simulations have been performed for the first time.

  1. A level set-based topology optimization method for simultaneous design of elastic structure and coupled acoustic cavity using a two-phase material model

    Science.gov (United States)

    Noguchi, Yuki; Yamamoto, Takashi; Yamada, Takayuki; Izui, Kazuhiro; Nishiwaki, Shinji

    2017-09-01

    This papers proposes a level set-based topology optimization method for the simultaneous design of acoustic and structural material distributions. In this study, we develop a two-phase material model that is a mixture of an elastic material and acoustic medium, to represent an elastic structure and an acoustic cavity by controlling a volume fraction parameter. In the proposed model, boundary conditions at the two-phase material boundaries are satisfied naturally, avoiding the need to express these boundaries explicitly. We formulate a topology optimization problem to minimize the sound pressure level using this two-phase material model and a level set-based method that obtains topologies free from grayscales. The topological derivative of the objective functional is approximately derived using a variational approach and the adjoint variable method and is utilized to update the level set function via a time evolutionary reaction-diffusion equation. Several numerical examples present optimal acoustic and structural topologies that minimize the sound pressure generated from a vibrating elastic structure.

  2. Deflection load characteristics of laser-welded orthodontic wires.

    Science.gov (United States)

    Watanabe, Etsuko; Stigall, Garrett; Elshahawy, Waleed; Watanabe, Ikuya

    2012-07-01

    To compare the deflection load characteristics of homogeneous and heterogeneous joints made by laser welding using various types of orthodontic wires. Four kinds of straight orthodontic rectangular wires (0.017 inch × 0.025 inch) were used: stainless-steel (SS), cobalt-chromium-nickel (Co-Cr-Ni), beta-titanium alloy (β-Ti), and nickel-titanium (Ni-Ti). Homogeneous and heterogeneous end-to-end joints (12 mm long each) were made by Nd:YAG laser welding. Two types of welding methods were used: two-point welding and four-point welding. Nonwelded wires were also used as a control. Deflection load (N) was measured by conducting the three-point bending test. The data (n  =  5) were statistically analyzed using analysis of variance/Tukey test (P welded specimens showed lower deflection loads compared to corresponding control wires and exhibited higher deflection loads compared to heterogeneously welded combinations. For homogeneous combinations, Co-Cr-Ni/Co-Cr-Ni showed a significantly (P welded groups. In heterogeneous combinations, SS/Co-Cr-Ni and β-Ti/Ni-Ti showed higher deflection loads than those of the remaining heterogeneously welded combinations (significantly higher for SS/Co-Cr-Ni). Significance (P welding method). However, no significant difference in deflection load was found between four-point and two-point welding in each homogeneous or heterogeneous combination. Heterogeneously laser-welded SS/Co-Cr-Ni and β-Ti/Ni-Ti wires provide a deflection load that is comparable to that of homogeneously welded orthodontic wires.

  3. Applicability valuation for evaluation of surface deflection in automotive outer panels

    Directory of Open Access Journals (Sweden)

    D.H. Park

    2008-12-01

    Full Text Available Purpose: Upon unloading in a forming process there is elastic recovery, which is the release of the elasticstrains and the redistribution of the residual stresses through the thickness direction, thus producing surfacedeflection. It causes changes in shape and dimensions that can create major problem in the external appearanceof outer panels. Thus surface deflection prediction is an important issue in sheet metal forming industry. Manyfactors could affect surface deflection in the process, such as material variations in mechanical properties, sheetthickness, tool geometry, processing parameters and lubricant condition.Design/methodology/approach: Numerical simulation of process was performed by the use of finite elementmethod, paying attention particularly to the thickness distribution and surface deflection of the drawn outerpanel and the outline flange during forming. Simulation procedures of automotive outer panel as large size shapeare as follows; 1 Acquisition of drawing parts 2 Laser scanning for generating CAD model 3 CAD modelgeneration 4 Simulation model operation 5 Simulation execution and analyses of simulation results.Findings: The development of automation in stamping and assembly processes of automobile manufacture willrequire an excellent surface quality of formed panels and also their accurate dimensions.Practical implications: The use of high strength steel sheets in the manufacturing of automobile outer panels hasincreased in the automotive industry over the years because of its lightweight and fuel-efficient improvement.But one of the major concerns of stamping is surface deflection in the formed outer panels. Hence, to be costeffective, accurate prediction must be made of its formability. The automotive industry places rigid constraintson final shape and dimensional tolerances as well as external appearance quality of outer panels. The numericalsimulation makes it possible to design and optimize the total process to a level

  4. Large deflection analysis of cantilever beam under end point and distributed load

    DEFF Research Database (Denmark)

    Kimiaeifar, Amin; Tolou, N; Barari, Amin;

    2014-01-01

    Although the deflection of beams has been studied for decades, the solutions were either linearized (i.e. small deflection) or based on elliptic integrals or functions (large deflection). The latter one includes the geometric nonlinearity but calculation of the deflection along the beam length re...

  5. The ESS elliptical cavity cryomodules

    Science.gov (United States)

    Darve, Christine; Bosland, Pierre; Devanz, Guillaume; Olivier, Gilles; Renard, Bertrand; Thermeau, Jean-Pierre

    2014-01-01

    The European Spallation Source (ESS) is a multi-disciplinary research centre under design and construction in Lund, Sweden. This new facility is funded by a collaboration of 17 European countries and is expected to be up to 30 times brighter than today's leading facilities and neutron sources. The ESS will enable new opportunities for researchers in the fields of life sciences, energy, environmental technology, cultural heritage and fundamental physics. A 5 MW long pulse proton accelerator is used to reach this goal. The pulsed length is 2.86 ms, the repetition frequency is 14 Hz (4 % duty cycle), and the beam current is 62.5 mA. The superconducting section of the Linac accelerates the beam from 80 MeV to 2.0 GeV. It is composed of one string of spoke cavity cryomodule and two strings of elliptical cavity cryomodules. These cryomodules contain four elliptical Niobium cavities operating at 2 K and at a frequency of 704.42 MHz. This paper introduces the thermo-mechanical design, the prototyping and the expected operation of the ESS elliptical cavity cryomodules. An Elliptical Cavity Cryomodule Technology Demonstrator (ECCTD) will be built and tested in order to validate the ESS series production.

  6. The ESS spoke cavity cryomodules

    Science.gov (United States)

    Bousson, Sebastien; Darve, Christine; Duthil, Patxi; Elias, Nuno; Molloy, Steve; Reynet, Denis; Thermeau, Jean-Pierre

    2014-01-01

    The European Spallation Source (ESS) is a multi-disciplinary research centre under design and construction in Lund, Sweden. This new facility is funded by a collaboration of 17 European countries and is expected to be up to 30 times brighter than today's leading facilities and neutron sources. The ESS will enable new opportunities for researchers in the fields of life sciences, energy, environmental technology, cultural heritage and fundamental physics. A 5 MW long pulse proton accelerator is used to reach this goal. The pulsed length is 2.86 ms, the repetition frequency is 14 Hz (4 % duty cycle), and the beam current is 62.5 mA. It is composed of one string of spoke cavity cryomodule and two strings of elliptical cavity cryomodules. This paper introduces the thermo-mechanical design and expected operation of the ESS spoke cavity cryomodules. These cryomodules contain two double spoke bulk Niobium cavities operating at 2 K and at a frequency of 352.21 MHz. The superconducting section of the Spoke Linac accelerates the beam from 90 MeV to 220 MeV. A Spoke Cavity Cryomodule Technology Demonstrator will be built and tested in order to validate the ESS series production.

  7. Mechanical Properties of Ingot Nb Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Ciovati, Gianluigi; Dhakal, Pashupati; Kneisel, Peter; Mammosser, John; Matalevich, Joseph; Rao Myneni, Ganapati

    2014-07-01

    This contribution presents the results of measurements of the resonant frequency and of strain along the contour of a single-cell cavity made of ingot Nb subjected to increasing uniform differential pressure, up to 6 atm. The data were used to infer mechanical properties of this material after cavity fabrication, by comparison with the results from simulation calculations done with ANSYS. The objective is to provide useful information about the mechanical properties of ingot Nb cavities which can be used in the design phase of SRF cavities intended to be built with this material.

  8. Experimental and theoretical analysis of DEP-based particle deflection for the separation of protein-bound particles

    Science.gov (United States)

    Kim, Min-Soo; Kim, Jong-Ho; Lee, Yoon-Sik; Lim, Geon-Gyu; Lee, Hyang-Beom; Park, Jae-Hyoung; Kim, Yong-Kweon

    2009-01-01

    We present an experimental and theoretical analysis of dielectrophoretic (DEP) particle deflection in a microfluidic channel for the separation of protein-bound particles. A 2D electrode array with widely spaced bars is designed to deflect a particle at the exit of the fluidic channel by negative DEP force. When particles pass through the channel, the particle streams are deflected differently depending on the DEP characteristics of the particles. In this paper, we propose methodologies to characterize the DEP force with the deflection distance using comparative analyses of a simulation and an experiment. The deflection distances of the particles are measured as a function of the ac voltage applied and compared with full 3D simulations. The Clausius-Mossotti (CM) factor of a protein-bound particle is analyzed, based on frequency-dependent deflection distance data measured experimentally, and protein-bound particles are separated from a mixture with nonbound particles in a real application. Two particle groups, 2.3 µm and 6.4 µm polystyrene particles, were used for the simulation and experimental study, and the 6.4 µm diameter particles were selected as an adequate protein-binding substrate for the application of biomolecular detection. Bovine serum albumin (BSA) was used as a test target protein. The particle's BSA binding is identified by the change in the particle's deflection distance. In particular, we used 1 wt% BSA as a target protein sample to investigate the deflection of 6.4 µm diameter particles as a function of protein concentration. The frequency-dependent CM factor curves for BSA-bound and nonbound particles are also calculated theoretically. Therefore, this paper shows a model analytic study on the biomolecular detection performance of a fabricated DEP-deflection microsystem. In addition, we present further significant analyses such as calculation of the electrical surface conductance of BSA around a particle, and we trace simulation errors. The

  9. Needle deflection estimation using fusion of electromagnetic trackers.

    Science.gov (United States)

    Sadjadi, H; Hashtrudi-Zaad, K; Fichtinger, G

    2012-01-01

    We present a needle deflection estimation method to compensate for needle bending during insertion into deformable tissue. We combine a kinematic needle deflection estimation model, electromagnetic (EM) trackers, and a Kalman filter (KF). We reduce the impact of error from the needle deflection estimation model by using the fusion of two EM trackers to report the approximate needle tip position in real-time. One reliable EM tracker is installed on the needle base, and estimates the needle tip position using the kinematic needle deflection model. A smaller but much less reliable EM tracker is installed on the needle tip, and estimates the needle tip position through direct noisy measurements. Using a KF, the sensory information from both EM trackers is fused to provide a reliable estimate of the needle tip position with much reduced variance in the estimation error. We then implement this method to compensate for needle deflection during simulated prostate cancer brachytherapy needle insertion. At a typical maximum insertion depth of 15 cm, needle tip mean estimation error was reduced from 2.39 mm to 0.31 mm, which demonstrates the effectiveness of our method, offering a clinically practical solution.

  10. Superconducting accelerating four-cell cavity

    CERN Multimedia

    1980-01-01

    A close view of the four-cell cavity. This was a prototype designed for LEP2 (LEP1 had warm copper cavities as accelerating elements). The first successful tests were made in December 1980 - reaching a Q = 10^6. (see photo 8012650X)

  11. Design and Operation of a Supersonic Flow Cavity for a Non-Self-Sustained Electric Discharge Pumped Oxygen-Iodine Laser

    Science.gov (United States)

    2007-02-16

    static pressure taps are shown along the bottom cavity wall. OMA V camera. The emission signal was collected using a Thor Labs 1 m long fibre optic bundle...in the supersonic cavity wall), and the opposite end of the fibre optic bundle was placed in front of the spectrometer slit. The use of the fibre ... optic link greatly improved the alignment of the optical diagnostics system. The O2(a 1) concentration in the discharge afterglow and the SDO yield were

  12. A STUDY OF FERRITE CAVITY.

    Energy Technology Data Exchange (ETDEWEB)

    ZHAO, Y.

    2002-04-19

    This note addresses the general concerns for the design of a ferrite cavity. The parameters are specified for the RCMS, for which the frequency ramp is in the range of 1.27 MHz to 6.44 MHz, or a ratio of 1:5.

  13. A micropillar for cavity optomechanics

    CERN Document Server

    Kuhn, A G; Ducloux, O; Chartier, C; Traon, O Le; Briant, T; Cohadon, P -F; Heidmann, A; Michel, C; Pinard, L; Flaminio, R

    2011-01-01

    We present a new micromechanical resonator designed for cavity optomechanics. We have used a micropillar geometry to obtain a high-frequency mechanical resonance with a low effective mass and a very high quality factor. We have coated a 60-$\\mu$m diameter low-loss dielectric mirror on top of the pillar and are planning to use this micromirror as part of a high-finesse Fabry-Perot cavity, to laser cool the resonator down to its quantum ground state and to monitor its quantum position fluctuations by quantum-limited optical interferometry.

  14. Ultrafast optical beam deflection in a pump probe configuration

    Science.gov (United States)

    Liang, Lingliang; Tian, Jinshou; Wang, Tao; Wu, Shengli; Li, Fuli; Wang, Junfeng; Gao, Guilong

    2016-09-01

    Propagation of a signal beam in an AlGaAs/GaAs waveguide multiple-prism light deflector is theoretically investigated by solving the scalar Helmholtz equation to obtain the dependences of the temporal and spatial resolvable characteristics of the ultrafast deflector on the material dispersion of GaAs including group velocity dispersion and angular dispersion, interface reflection, and interface scattering of multiple-prism deflector. Furthermore, we experimentally confirm that, in this ultrafast beam deflection device, the deflecting angle of the signal light beam is linear with the pump fluence and the temporal resolution of the ultrafast deflection is 10 ps. Our results show that the improvement of the temporal and spatial resolvable performances is possible by properly choosing the structural parameters and enhancing the quality of the device. Project supported by the National Natural Science Foundation of China (Grant Nos. 11274377 and 61176006) and the State Major Research Equipment Project, China (Grant No. ZDY2011-2).

  15. ABRUPT DEFLECTED SUPERCRITICAL WATER FLOW IN SLOPED CHANNELS

    Institute of Scientific and Technical Information of China (English)

    LIU Ya-kun; NI Han-gen

    2008-01-01

    The effect of the bottom slope on abrupt deflected supercritical water flow was experimentally and theoretically studied. Model tests were conducted in a flume of 1.2 m wide and 2.6 m long with sloped bottom at an angle 35.54o, its length of deflector was 0.2 m and the deflection angles were 15o and 30o. An approximate method for calculatjng the shock wave angle and depth ratio of the abrupt deflected supercritical water flow was suggested, and a correction coefficient for the hydrodynamic pressure was introduced to generalize the momentum equation in the direction perpendicular to the shock front. It must be noticed that in the sloped channel the shock wave angle and the depth ratio are no longer constant as those in the horizontal channels, but slowly change along the shock front. The calculated results are in good agreement with measured data.

  16. Linearizing Intra-Train Beam-Beam Deflection Feedback

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.R.; /SLAC

    2006-02-22

    Beam-beam deflection feedback acting within the crossing time of a single bunch train may be needed to keep linear collider beams colliding at high luminosity. In a short-pulse machine such as the Next Linear Collider (NLC) this feedback must converge quickly to be useful. The non-linear nature of beam-beam deflection vs. beam-beam offset in these machines precludes obtaining both rapid convergence and a stable steady-state lock to beam offsets with a linear feedback algorithm. We show that a simply realizable programmable non-linear amplifier in the feedback loop can linearize the feedback loop, approximately compensating the beam-beam deflection non-linearity. Performance of a prototype non-linear amplifier is shown. Improvement of convergence and stability of the beam-beam feedback loop is simulated.

  17. Evaluation of force released by deflection of orthodontic wires in conventional and self-ligating brackets

    Science.gov (United States)

    Higa, Rodrigo Hitoshi; Semenara, Nayara Thiago; Henriques, José Fernando Castanha; Janson, Guilherme; Sathler, Renata; Fernandes, Thais Maria Freire

    2016-01-01

    ABSTRACT Introduction: The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM), active (In-Ovation RTM) and passive (Damon 3MXTM) self-ligating brackets. Material and Methods: Two brands of stainless steel and nickel-titanium (NiTi) wires (MorelliTM and GACTM), in addition to OrmcoTM copper-nickel-titanium wires were used. Specimens were assembled in a clinical simulation device especially designed for this study and tested in an Instron universal testing machine. For the testing procedures, an acrylic structure representative of the maxillary right central incisor was lingually moved in activations of 0 to 1 mm, with readings of the force released by deflection in unloading of 0.5, 0.8 and 1 mm at a constant speed of 2 mm/min. Inter-bracket forces with stainless steel, NiTi and CuNiTi were individually compared by two-way ANOVA, followed by Tukey’s tests. Results: Results showed that there were lower forces in conventional brackets, followed by active and passive self-ligating brackets. Within the brands, only for NiTi wires, the MorelliTM brand presented higher forces than GACTM wires. Conclusions: Bracket systems provide different degrees of deflection force, with self-ligating brackets showing the highest forces. PMID:28125144

  18. Evaluation of force released by deflection of orthodontic wires in conventional and self-ligating brackets

    Directory of Open Access Journals (Sweden)

    Rodrigo Hitoshi Higa

    Full Text Available ABSTRACT Introduction: The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM, active (In-Ovation RTM and passive (Damon 3MXTM self-ligating brackets. Material and Methods: Two brands of stainless steel and nickel-titanium (NiTi wires (MorelliTM and GACTM, in addition to OrmcoTM copper-nickel-titanium wires were used. Specimens were assembled in a clinical simulation device especially designed for this study and tested in an Instron universal testing machine. For the testing procedures, an acrylic structure representative of the maxillary right central incisor was lingually moved in activations of 0 to 1 mm, with readings of the force released by deflection in unloading of 0.5, 0.8 and 1 mm at a constant speed of 2 mm/min. Inter-bracket forces with stainless steel, NiTi and CuNiTi were individually compared by two-way ANOVA, followed by Tukey’s tests. Results: Results showed that there were lower forces in conventional brackets, followed by active and passive self-ligating brackets. Within the brands, only for NiTi wires, the MorelliTM brand presented higher forces than GACTM wires. Conclusions: Bracket systems provide different degrees of deflection force, with self-ligating brackets showing the highest forces.

  19. Dynamics and control of a solar collector system for near Earth object deflection *

    Institute of Scientific and Technical Information of China (English)

    Shen-Ping Gong; Jun-Feng Li; Yun-Feng Gao

    2011-01-01

    A solar collector system is a possible method using solar energy to deflect Earth-threatening near-Earth objects. We investigate the dynamics and control of a solar collector system including a main collector (MC) and secondary collector (SC).The MC is used to collect the sunlight to its focal point, where the SC is placed and directs the collected light to an asteroid. Both the relative position and attitude of the two collectors should be accurately controlled to achieve the desired optical path. First,the dynamical equation of the relative motion of the two collectors in the vicinity of the asteroid is modeled. Secondly, the nonlinear sliding-mode method is employed to design a control law to achieve the desired configuration of the two collectors. Finally,the deflection capability of this solar collector system is compared with those of the gravitational tractor and solar sail gravitational tractor. The results show that the solar collector is much more efficient with respect to deflection capability.

  20. Smart earthquake-resistant materials: using time-released adhesives for damping, stiffening, and deflection control

    Science.gov (United States)

    Dry, Carolyn M.

    1996-04-01

    Preventing buildings and bridges from damage from severe dynamic loading events is a primary goal of civil infrastructure. Present designs attempt to control structural response by making the structures more massive, by increasing lateral stiffness through bracing, and by damping technology such as mass damping and base-isolation. These attempts affect portions of the governing equation: for an idealized building frame or bridge, the free vibrational behavior is described by Mu + cu + ku equals -mug(t) where m equals mass, c equals damping coefficient, k equals lateral stiffness, u equals deflection, and ug(t) equals ground acceleration. The use of adhesive released internally in a material based way of addressing the problem. The time release of low modulus adhesive chemicals would assist the damping characteristics of the structure, use of a stiffer adhesive would allow the damaged structure to regain some lateral stiffness (k) and adjustment of the set times of the adhesives would act to control the deflection. These can be thought of as potential new method of controlling vibration of behavior in case of a dynamic loading event. In past experiments, self-healing concrete matrices were shown to increase post-yield deflection and load carrying capability by the release and setting of adhesives. The results were promising in resisting damage of dynamic loads applied to frames. This indicates that self-healing concrete would be extremely valuable in civil engineering structures that were subjected to failure-inducing loads such as earthquakes.

  1. A New Four States High Deflection Low Actuation Voltage Electrostatic Mems Switch for RF Applications

    CERN Document Server

    Robin, Renaud; Segueni, Karim; Millet, Olivier; Buchaillot, Lionel

    2008-01-01

    This paper presents a new electrostatic MEMS (MicroElectroMechanical System) based on a single high reliability totally free flexible membrane. Using four electrodes, this structure enables four states which allowed large deflections (4$\\mu$m) with low actuation voltage (7,5V). This design presents also a good contact force and improve the restoring force of the structure. As an example of application, a Single Pole Double Throw (SPDT) for 24GHz applications, based on this design, has been simulated.

  2. Shape Tracking of a Dexterous Continuum Manipulator Utilizing Two Large Deflection Shape Sensors

    Science.gov (United States)

    Farvardin, Amirhossein; Grupp, Robert; Murphy, Ryan J.; Taylor, Russell H.; Iordachita, Iulian

    2016-01-01

    Dexterous continuum manipulators (DCMs) can largely increase the reachable region and steerability for minimally and less invasive surgery. Many such procedures require the DCM to be capable of producing large deflections. The real-time control of the DCM shape requires sensors that accurately detect and report large deflections. We propose a novel, large deflection, shape sensor to track the shape of a 35 mm DCM designed for a less invasive treatment of osteolysis. Two shape sensors, each with three fiber Bragg grating sensing nodes is embedded within the DCM, and the sensors’ distal ends fixed to the DCM. The DCM centerline is computed using the centerlines of each sensor curve. An experimental platform was built and different groups of experiments were carried out, including free bending and three cases of bending with obstacles. For each experiment, the DCM drive cable was pulled with a precise linear slide stage, the DCM centerline was calculated, and a 2D camera image was captured for verification. The reconstructed shape created with the shape sensors is compared with the ground truth generated by executing a 2D–3D registration between the camera image and 3D DCM model. Results show that the distal tip tracking accuracy is 0.40 ± 0.30 mm for the free bending and 0.61 ± 0.15 mm, 0.93 ± 0.05 mm and 0.23 ± 0.10 mm for three cases of bending with obstacles. The data suggest FBG arrays can accurately characterize the shape of large-deflection DCMs.

  3. RRR Characteristics for SRF Cavities

    CERN Document Server

    Jung, Yoochul; Joung, Mijoung

    2015-01-01

    The first heavy ion accelerator is being constructed by the rare isotope science project (RISP) launched by the Institute of Basic Science (IBS) in South Korea. Four different types of superconducting cavities were designed, and prototypes were fabricated such as a quarter wave resonator (QWR), a half wave resonator (HWR) and a single spoke resonator (SSR). One of the critical factors determining performances of the superconducting cavities is a residual resistance ratio (RRR). The RRR values essentially represent how much niobium is pure and how fast niobium can transmit heat as well. In general, the RRR degrades during electron beam welding due to the impurity incorporation. Thus it is important to maintain RRR above a certain value at which a niobium cavity shows target performance. In this study, RRR degradation related with electron beam welding conditions, for example, welding power, welding speed, and vacuum level will be discussed.

  4. Two-mode polarized traveling wave deflecting structure

    Institute of Scientific and Technical Information of China (English)

    谭建豪; 顾强; 方文程; 童德春; 赵振堂

    2015-01-01

    In this paper, we propose a two-mode polarizable deflecting structure, as a new concept for bunch measure-ment and beam control. With two modes of HEM11 and HEM12 operating in the same structure on horizontal and vertical directions, respectively, the operation status can be switched between the two polarization modes. They can be operated simultaneously with two independent input power sources. With two-mode deflecting structure, the bunch distortion caused by the geometric wake-fields in the accelerating structure can be mea-sured by one structure.

  5. Nuclear cycler: An incremental approach to the deflection of asteroids

    Science.gov (United States)

    Vasile, Massimiliano; Thiry, Nicolas

    2016-04-01

    This paper introduces a novel deflection approach based on nuclear explosions: the nuclear cycler. The idea is to combine the effectiveness of nuclear explosions with the controllability and redundancy offered by slow push methods within an incremental deflection strategy. The paper will present an extended model for single nuclear stand-off explosions in the proximity of elongated ellipsoidal asteroids, and a family of natural formation orbits that allows the spacecraft to deploy multiple bombs while being shielded by the asteroid during the detonation.

  6. Research on network failure handling technology based on deflection routing

    Institute of Scientific and Technical Information of China (English)

    Tao YU; Shanzhi CHEN; Xin LI; Zhen QIN

    2008-01-01

    A new deflection routing scheme is proposed to overcome the drawback of existing deflection routing scheme that cannot handle node failure and suffer from routing loops.A new algorithm for computing the backup shortest path tree(SPT)is proposed and a set of procedures are defined for utilizing the backup SPT in case of node or link failure.The failure can be handled swiftly and the backup routes are guaranteed to be loop-free.Experimental results show that the backup routes calculated by proposed scheme are close to the optimal routes by totally re-computing.

  7. The 1919 measurement of the deflection of light

    CERN Document Server

    Will, Clifford M

    2014-01-01

    The measurement of the deflection of starlight during a total solar eclipse on May 29, 1919 was the first verification of general relativity by an external team of scientists, brought Einstein and his theory to the attention of the general public, and left a legacy of experimental testing that continues today. The discovery of gravitational lenses turned Einstein's deflection into an important tool for astronomy and cosmology. This article reviews the history of the 1919 measurement and other eclipse measurements, describes modern measurements of the effect using radio astronomy, and of its cousin, the Shapiro time delay, and discusses gravitational lenses.

  8. Dawn of Cavity Spintronics

    OpenAIRE

    Hu, Can-Ming

    2015-01-01

    Merging the progress of spintronics with the advancement in cavity quantum electrodynamics and cavity polaritons, a new field of Cavity Spintronics is forming, which connects some of the most exciting modern physics, such as quantum information and quantum optics, with one of the oldest science on the earth, the magnetism.

  9. Absorption characteristics of anechoic coating on cavity structure and its optimization design%混合型空腔结构覆盖层吸声性能研究及其优化设计

    Institute of Scientific and Technical Information of China (English)

    商超; 张嘉钟; 曹伟; 于开平

    2011-01-01

    基于有限元法研究了以空气为背衬的混合型空腔结构覆盖层的吸声特性.建立了具有混合型空腔结构的覆盖层有限元模型,对其进行吸声特性数值仿真分析.结果表明,该空腔结构的吸声特性明显优于相同穿孔率的单腔结构.通过优化设计,进一步提升了混合型空腔结构覆盖层在全频段的吸声性能,并得到了若干覆盖层结构参数影响其吸声性能的规律.%The absorption characteristics of the mixed-cavity structure anechoic coating with air backing were studied by using finite element method. The calculation results indicate that the absorption characteristics of this kind of cavity structure are superior to those of single-cavity structure under the same perforated percentage. Then, the absorption properties of anechoic coating on mixed-cavity structure at full-frequency range were further improved by optimization design. The influence of coating structure parameters on absorption characteristics was studied.

  10. Optical fiber tips functionalized with semiconductor photonic crystal cavities

    CERN Document Server

    Shambat, Gary; Rivoire, Kelley; Sarmiento, Tomas; Harris, James; Vuckovic, Jelena

    2011-01-01

    We demonstrate a simple and rapid epoxy-based method for transferring photonic crystal cavities to the facets of optical fibers. Passive Si cavities were measured via fiber taper coupling as well as direct transmission from the fiber facet. Active quantum dot containing GaAs cavities showed photoluminescence that was collected both in free space and back through the original fiber. Cavities maintain a high quality factor (2000-4000) in both material systems. This new design architecture provides a practical mechanically stable platform for the integration of photonic crystal cavities with macroscale optics and opens the door for novel research on fiber-coupled cavity devices.

  11. Supersonic flows over cavities

    Institute of Scientific and Technical Information of China (English)

    Tianwen FANG; Meng DING; Jin ZHOU

    2008-01-01

    The characteristics of supersonic cold flows over cavities were investigated experimentally and numer-ically, and the effects of cavities of different sizes on super-sonic flow field were analyzed. The results indicate that the ratio of length to depth L/D within the range of 5-9 has little relevance to integral structures of cavity flow. The bevel angle of the rear wall does not alter the overall structure of the cavity flow within the range of 30°-60°, but it can exert obvious effect on the evolvement of shear layer and vortexes in cavities.

  12. Beam cavity interaction

    CERN Document Server

    Gamp, A

    2011-01-01

    We begin by giving a description of the rf generator-cavity-beam coupled system in terms of basic quantities. Taking beam loading and cavity detuning into account, expressions for the cavity impedance as seen by the generator and as seen by the beam are derived. Subsequently methods of beam-loading compensation by cavity detuning, rf feedback, and feed-forward are described. Examples of digital rf phase and amplitude control for the special case of superconducting cavities are also given. Finally, a dedicated phase loop for damping synchrotron oscillations is discussed.

  13. THE EFFECT OF CORRUGATED ELEMENTS THICKNESS ON THE DEFLECTED MODE OF CORRUGATED METAL STRUCTURES

    Directory of Open Access Journals (Sweden)

    V. V. Kovalchuk

    2015-06-01

    Full Text Available Purpose. The work provides research the deflected mode and calculation the relative deformation of vertical and horizontal diameters of corrugated metal structures (CMS, horizontal ellipse type, and cross section in their interaction with soil backfill depending on the thickness of corrugated metal pipe. Such studies are required for optimal design of CMS, establishing the causes of defects timely, appropriate engineering solutions to improve the bearing capacity of the CMS and reasonable use of funds for their construction or rehabilitation of existing transportation facilities using corrugated metal pipes. Methodology. Stresses and stability calculations of CMS form are conducted using the developed mathematical algorithm in program environment Mathcad 14. In these studies different thickness of corrugated metal pipe were assigned, and further calculations were carried out at the design value of backfill soil compaction degree and magnitude of dynamic loading of railway transport. Findings. From the calculations is determined that the most influence the thickness of the corrugated metal pipe has on the strength in the calculation of the normal stresses and value of the vertical pipe strains. Therefore, the calculated parameters in the design of corrugated metal structures with small filling heights (from 1.2 m to 3 m above its peak is calculation of the strength by the normal stresses and determination of the vertical deformation of the pipe. Originality. For the first time, calculations of the deflected mode and relative deformations of vertical and horizontal cross-sectional diameters of CMS, horizontal ellipse type in the interaction with soil backfill. The factors complex was taken into account the backfill soil compaction degree, the value of dynamic loading of railway transport and different thickness of corrugated metal pipe. Practical value. The results of the deflected mode of corrugated metal structures such as horizontal ellipse of

  14. Hydrodynamic Drag on Streamlined Projectiles and Cavities

    KAUST Repository

    Jetly, Aditya

    2016-04-19

    The air cavity formation resulting from the water-entry of solid objects has been the subject of extensive research due to its application in various fields such as biology, marine vehicles, sports and oil and gas industries. Recently we demonstrated that at certain conditions following the closing of the air cavity formed by the initial impact of a superhydrophobic sphere on a free water surface a stable streamlined shape air cavity can remain attached to the sphere. The formation of superhydrophobic sphere and attached air cavity reaches a steady state during the free fall. In this thesis we further explore this novel phenomenon to quantify the drag on streamlined shape cavities. The drag on the sphere-cavity formation is then compared with the drag on solid projectile which were designed to have self-similar shape to that of the cavity. The solid projectiles of adjustable weight were produced using 3D printing technique. In a set of experiments on the free fall of projectile we determined the variation of projectiles drag coefficient as a function of the projectiles length to diameter ratio and the projectiles specific weight, covering a range of intermediate Reynolds number, Re ~ 104 – 105 which are characteristic for our streamlined cavity experiments. Parallel free fall experiment with sphere attached streamlined air cavity and projectile of the same shape and effective weight clearly demonstrated the drag reduction effect due to the stress-free boundary condition at cavity liquid interface. The streamlined cavity experiments can be used as the upper bound estimate of the drag reduction by air layers naturally sustained on superhydrophobic surfaces in contact with water. In the final part of the thesis we design an experiment to test the drag reduction capacity of robust superhydrophobic coatings deposited on the surface of various model vessels.

  15. RESONANT CAVITY EXCITATION SYSTEM

    Science.gov (United States)

    Baker, W.R.; Kerns, Q.A.; Riedel, J.

    1959-01-13

    An apparatus is presented for exciting a cavity resonator with a minimum of difficulty and, more specifically describes a sub-exciter and an amplifier type pre-exciter for the high-frequency cxcitation of large cavities. Instead of applying full voltage to the main oscillator, a sub-excitation voltage is initially used to establish a base level of oscillation in the cavity. A portion of the cavity encrgy is coupled to the input of the pre-exciter where it is amplified and fed back into the cavity when the pre-exciter is energized. After the voltage in the cavity resonator has reached maximum value under excitation by the pre-exciter, full voltage is applied to the oscillator and the pre-exciter is tunned off. The cavity is then excited to the maximum high voltage value of radio frequency by the oscillator.

  16. Diffraction-limited Fabry-Perot Cavity in the Near Concentric Regime

    CERN Document Server

    Durak, Kadir; Leong, Victor; Straupe, Stanislav; Kurtsiefer, Christian

    2014-01-01

    Nearly concentric optical cavities can be used to prepare optical fields with a very small mode volume. We implement an anaclastic design of a such a cavity that significantly simplifies mode matching to the fundamental cavity mode. The cavity is shown to have diffraction-limited performance for a mode volume of $\\approx10^4\\lambda^3$. This is in sharp contrast with the behavior of cavities with plano-concave mirrors, where aberrations significantly increase the losses in the fundamental mode. We estimate the related cavity QED parameters and show that the proposed cavity design allows for strong coupling without a need for high finesse or small physical cavity volume.

  17. Comparison of Multi-field Coupling Analysis of Accelerator Cavity

    Institute of Scientific and Technical Information of China (English)

    LI; Chun-guang; LI; Jin-hai

    2013-01-01

    In the high power accelerator cavity,the joule heat produced by the electromagnetic fields causes the temperature of the cavity rising which leads to frequency changed,called frequency shift.The analysis of the effect of power to the frequency shift is an important task of accelerator cavity design.It involves heat,structure and high frequency analysis.

  18. Vector separation of particles and cells using an array of slanted open cavities

    CERN Document Server

    Bernate, Jorge A; Lagae, Liesbet; Konstantopoulo, Konstantinos; Drazer, German

    2014-01-01

    We present a microfluidic platform for the continuous separation of suspended particles based on their size and settling velocity. The separation method takes advantage of the flow field in the vicinity and inside a parallel array of slanted open cavities. These cavities induce flow along them, which deflects the suspended particles to a different degree depending on the extent to which they penetrate into the cavities. The cumulative deflection in the periodic array ultimately leads to vector chromatography, with the different species in the sample moving in different directions. We demonstrate density and size based separation over a range of flow rates by separating polystyrene and silica particles and show that purities nearing 100% can be achieved for multicomponent mixtures. We also demonstrate the potential of the platform to separate biological cells by fractionating different blood components. We discuss the presence of two regimes, which can be distinguished depending on the ratio between the settli...

  19. The effect of asteroid topography on surface ablation deflection

    Science.gov (United States)

    McMahon, Jay W.; Scheeres, Daniel J.

    2017-02-01

    Ablation techniques for deflecting hazardous asteroids deposit energy into the asteroid's surface, causing an effective thrust on the asteroid as the ablating material leaves normal to the surface. Although it has long been recognized that surface topography plays an important role in determining the deflection capabilities, most studies to date have ignored this aspect of the model. This paper focuses on understanding the topography for real asteroid shapes, and how this topography can change the deflection performance of an ablation technique. The near Earth asteroids Golevka, Bennu, and Itokawa are used as the basis for this study, as all three have high-resolution shape models available. This paper shows that naive targeting of an ablation method without accounting for the surface topography can lower the deflection performance by up to 20% in the cases studied in terms of the amount of acceleration applied in the desired direction. If the ablation thrust level is assumed to be 100 N, as used elsewhere in the literature, this misapplication of thrust translates to tens of kilometers per year in decreased semimajor axis change. However, if the ablation method can freely target any visible point on the surface of the asteroid, almost all of this performance can be recovered.

  20. Deflection of Light by Gravity: A Physical Approach.

    Science.gov (United States)

    Diamond, Joshua B.

    1982-01-01

    Einstein's equivalence principle relates effects seen by an accelerating observer to those experienced by an observer in a gravitational field, providing an explanation of bending of a light beam by gravity. Because the calculations lead to results one-half the value found experimentally, obtaining the correct light deflection is discussed.…

  1. On guided versus deflected fields in controlled-source electromagnetics

    Science.gov (United States)

    Swidinsky, Andrei

    2015-06-01

    The detection of electrically resistive targets in applied geophysics is of interest to the hydrocarbon, mining and geotechnical industries. Elongated thin resistive bodies have been extensively studied in the context of offshore hydrocarbon exploration. Such targets guide electromagnetic fields in a process which superficially resembles seismic refraction. On the other hand, compact resistive bodies deflect current in a process which has more similarities to diffraction and scattering. The response of a real geological structure is a non-trivial combination of these elements-guiding along the target and deflection around its edges. In this note the electromagnetic responses of two end-member models are compared: a resistive layer, which guides the electromagnetic signal, and a resistive cylinder, which deflects the fields. Results show that the response of a finite resistive target tends to saturate at a much lower resistivity than a resistive layer, under identical survey configurations. Furthermore, while the guided electromagnetic fields generated by a buried resistive layer contain both anomalous horizontal and vertical components, the process of electromagnetic deflection from a buried resistive cylinder creates mainly anomalous vertical fields. Finally, the transmitter orientation with respect to the position of a finite body is an important survey parameter: when the distance to the target is much less than the host skin depth, a transmitter pointing towards the resistive cylinder will produce a stronger signal than a transmitter oriented azimuthally with respect to the cylinder surface. The opposite situation is observed when the distance to the target is greater than the host skin depth.

  2. Large deflection analysis of skew plates under uniformly distributed ...

    African Journals Online (AJOL)

    user

    load-deflection plane to show the effect of skew angle, aspect ratio and boundary condition. ... by edge 1, 2, 3 and 4 on the plate boundaries in Figures 1(a)-1(d). ... one-dimensional coordinate functions along normalized coordinate are shown ...

  3. An Analytical Model of Wake Deflection Due to Shear Flow

    NARCIS (Netherlands)

    Micallef, D.; Simao Ferreira, C.J.; Sant, T.; Van Bussel, G.J.W.

    2010-01-01

    The main motivation behind this work is to create a purely analytical engineering model for wind turbine wake upward deflection due to shear flow, by developing a closed form solution of the velocity field due to an oblique vortex ring. The effectiveness of the model is evaluated by comparing the re

  4. Deflection routing scheme for GMPLS-based OBS networks

    DEFF Research Database (Denmark)

    Eid, Arafat; Mahmood, Waqar; Alomar, Anwar

    2010-01-01

    is not applicable in such an integrated solution. This is due to the existence of already established Label Switched Paths (LSPs) between edge nodes in a GMPLS-based OBS network which guide the Data Burst Headers (DBHs) through the network. In this paper we propose a novel deflection routing scheme which can...

  5. Towards a mechanistic analysis of Benkelman beam deflection measurements

    NARCIS (Netherlands)

    Visser, A.F.H.M.; Priambodo Koesrindartono, D.

    2000-01-01

    This paper introduces and describes the Benkelman beam deflection test. Furthermore Benkelman beam tests are simulated using two multi-layer programs, based on an elastic and visco-elastic material model for asphalt. The results of these two programs are compared with each other. Finally, using the

  6. Cantilever deflection measurement and actuation by an nterdigitated transducer

    NARCIS (Netherlands)

    Strambini, E.; Piazza, V.; Pingue, P.; Biasiol, G.; Sorba, L.; Beltram, F.

    2010-01-01

    A scheme that allows all-electrical high-bandwidth readout of a cantilever deflection by means of an integrated interdigitated transducer is presented. The present approach takes advantage of the piezoelectricity of the chosen cantilever substrate material to generate and detect surface-acoustic-wav

  7. Observation of Beam-beam Deflections with LHC Orbit Data

    CERN Document Server

    Kozanecki, W; Wenninger, J

    2013-01-01

    The LHC luminosity is calibrated in dedicated fills with van der Meer scans (vdM) of the beams that are performed repeatedly in both planes. During vdM scans the relative separation of the two LHC beams is scanned in a range of ±6 sigma , where sigma is the single beam size, probing the beam-beam deflection over a relatively large range. Orbit data logged parasitically during those scans were analysed and the beam-beam deflections at the IP being scanned could be reconstructed from orbit fits in the LHC arcs surrounding the IP. Despite the small size of the kicks (≤ 1μrad) the coherent beam-beam deflections are clearly resolved. The beam parameters that are extracted from the fit to the beam-beam deflection data were compared to luminosity data fits and they were found to be in good agreement. The closed orbit shift due to the beam-beam kick is also clearly observed in the beam position interpolation at the collision point.

  8. Cavity turnover and equilibrium cavity densities in a cottonwood bottomland

    Science.gov (United States)

    Sedgwick, James A.; Knopf, Fritz L.

    1992-01-01

    A fundamental factor regulating the numbers of secondary cavity nesting (SCN) birds is the number of extant cavities available for nesting. The number of available cavities may be thought of as being in an approximate equilibrium maintained by a very rough balance between recruitment and loss of cavities. Based on estimates of cavity recruitment and loss, we ascertained equilibrium cavity densities in a mature plains cottonwood (Populus sargentii) bottomland along the South Platte River in northeastern Colorado. Annual cavity recruitment, derived from density estimates of primary cavity nesting (PCN) birds and cavity excavation rates, was estimated to be 71-86 new cavities excavated/100 ha. Of 180 active cavities of 11 species of cavity-nesting birds found in 1985 and 1986, 83 were no longer usable by 1990, giving an average instantaneous rate of cavity loss of r = -0.230. From these values of cavity recruitment and cavity loss, equilibrium cavity density along the South Platte is 238-289 cavities/100 ha. This range of equilibrium cavity density is only slightly above the minimum of 205 cavities/100 ha required by SCN's and suggests that cavity availability may be limiting SCN densities along the South Platte River. We submit that snag management alone does not adequately address SCN habitat needs, and that cavity management, expressed in terms of cavity turnover and cavity densities, may be more useful.

  9. LHC Crab Cavity Coupler Test Boxes

    CERN Document Server

    Mitchell, James; Burt, Graeme; Calaga, Rama; Macpherson, Alick; Montesinos, Eric; Silva, Subashini; Tutte, Adam; Xiao, Binping

    2016-01-01

    The LHC double quarter wave (DQW) crab cavities have two different types of Higher Order Mode (HOM) couplers in addition to a fundamental power coupler (FPC). The FPC requires conditioning, so to achieve this we have designed a radio-frequency (RF) quarter wave resonator to provide high transmission between two opposing FPCs. For the HOM couplers we must ensure that the stop-band filter is positioned at the cavity frequency and that peak transmission occurs at the same frequencies as the strongest HOMs. We have designed two test boxes which preserve the cavity spectral response in order to test the couplers.

  10. Electrically Pumped Vertical-Cavity Amplifiers

    DEFF Research Database (Denmark)

    Greibe, Tine

    2007-01-01

    In this work, the design of electrically pumped vertical cavity semiconductor optical amplifiers (eVCAs) for use in a mode-locked external-cavity laser has been developed, investigated and analysed. Four different eVCAs, one top-emitting and three bottom emitting structures, have been designed...... and discussed. The thesis concludes with recommendations for further work towards the realisation of compact electrically pumped mode-locked vertical externalcavity surface emitting lasers....

  11. Installation and Commissioning of CYCIAE-100 RF Cavity

    Institute of Scientific and Technical Information of China (English)

    JI; Bin; XING; Jian-sheng; LIU; Geng-shou; YIN; Zhi-guo; ZHANG; Tian-jue; LEI; Yu; FU; Xiao-liang; LI; Peng-zhan; LV; Yin-long; ZHU; Peng-fei; FU; Li-cheng; LIU; Jie; ZHANG; De-zhi; CUI; Bai-yao; DONG; Huan-jun; WANG; Zhen-hui

    2013-01-01

    The RF cavity is used to establish electrical field for the particle acceleration in the cyclotron,the stability of the RF cavity affects the RF system directly.A RF cavity with high quality can reduce thepower consumption of the RF system and make the cooling system simple.A good design is the first step towards RF cavity with high quality.The installation and commissioning are the next important process to achieve an excellent performance.The height of the

  12. Design of novel three port optical gates scheme for the integration of large optical cavity electroabsorption modulators and evanescently-coupled photodiodes

    Institute of Scientific and Technical Information of China (English)

    Liao Zai-Yi; Yang Hua; Wang Wei

    2008-01-01

    This paper presents a novel scheme to monolithically integrate an evanescently-coupled uni-travelling carrier photodiode with a planar short multimode waveguide structure and a large optical cavity electroabsorption modulator based on a multimode waveguide structure. By simulation, both electroabsorption modulator and photodiode show excellent optical performances. The device can be fabricated with conventional photolithography, reactive ion etching, and chemical wet etching.

  13. CLASSICAL AREAS OF PHENOMENOLOGY: Design of novel three port optical gates scheme for the integration of large optical cavity electroabsorption modulators and evanescently-coupled photodiodes

    Science.gov (United States)

    Liao, Zai-Yi; Yang, Hua; Wang, Wei

    2008-07-01

    This paper presents a novel scheme to monolithically integrate an evanescently-coupled uni-travelling carrier photodiode with a planar short multimode waveguide structure and a large optical cavity electroabsorption modulator based on a multimode waveguide structure. By simulation, both electroabsorption modulator and photodiode show excellent optical performances. The device can be fabricated with conventional photolithography, reactive ion etching, and chemical wet etching.

  14. 805 MHz and 201 MHz RF cavity development for MUCOOL

    Energy Technology Data Exchange (ETDEWEB)

    Li, Derun [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Corlett, J [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Ladran, A [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); MacGill, R [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Wallig, J [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Zisman, M [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Moretti, A [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Rowe, A [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Qian, Z B [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Wu, V [Fermi National Accelerator Laboratory, Batavia, IL 60510 (United States); Rimmer, R A [Jefferson Lab, Newport News, VA 23606 (United States); Norem, J [Argonne National Laboratory, Argonne, IL 60439 (United States); Summers, D [University of Mississippi at Oxford, MS 38677 (United States); Torun, Y [Illinois Institute of Technology, Chicago, IL 60616 (United States)

    2003-08-01

    A muon cooling channel calls for very high accelerating gradient RF structures to restore the energy lost by muons in the absorbers. The RF structures have to be operated in a strong magnetic field and thus the use of superconducting RF cavities is excluded. To achieve a high shunt impedance while maintaining a large enough aperture to accommodate a large transverse emittance muon beam, the cavity design adopted is a pillbox-like geometry with thin Be foils to terminate the electromagnetic field at the cavity iris. The possibility of using grids of thin-walled metallic tubes for the termination is also being explored. Many of the RF-related issues for muon cooling channels are being studied both theoretically and experimentally using an 805 MHz cavity that has a pillbox-like geometry with thin Be windows to terminate the cavity aperture. The design and performance of this cavity are reported here. High-power RF tests of the 805 MHz cavity are in progress at Lab G in Fermilab. The cavity has exceeded its design gradient of 30 MV m{sup -1}, reaching 34 MV m{sup -1} without external magnetic field. No surface damage was observed at this gradient. The cavity is currently under conditioning at Lab G with an external magnetic field of 2.5 T. We also present here a 201 MHz cavity design for muon cooling channels. The proposed cavity design is also suitable for use in a proof-of-principle muon ionization cooling experiment.

  15. A hemispherical, high-solid-angle optical micro-cavity for cavity-QED studies

    Science.gov (United States)

    Cui, Guoqiang; Hannigan, J. M.; Loeckenhoff, R.; Matinaga, F. M.; Raymer, M. G.; Bhongale, S.; Holland, M.; Mosor, S.; Chatterjee, S.; Gibbs, H. M.; Khitrova, G.

    2006-03-01

    We report a novel hemispherical micro-cavity that is comprised of a planar integrated semiconductor distributed Bragg reflector (DBR) mirror, and an external, concave micro-mirror having a radius of curvature 50 µm. The integrated DBR mirror containing quantum dots (QD), is designed to locate the QDs at an antinode of the field in order to maximize the interaction between the QD and cavity. The concave micro-mirror, with high-reflectivity over a large solid-angle, creates a diffraction-limited (sub-micron) mode-waist at the planar mirror, leading to a large coupling constant between the cavity mode and QD. The half-monolithic design gives more spatial and spectral tuning abilities, relatively to fully monolithic structures. This unique micro-cavity design will potentially enable us to both reach the cavity quantum electrodynamics (QED) strong coupling regime and realize the deterministic generation of single photons on demand.

  16. Vertical-Cavity Surface-Emitting Lasers

    Science.gov (United States)

    Wilmsen, Carl W.; Temkin, Henryk; Coldren, Larry A.

    2002-01-01

    1. Introduction to VCSELs L. A. Coldren, C. W. Wilmsen and H. Temkin; 2. Fundamental issues in VCSEL design L. A. Coldren and Eric R. Hegblom; 3. Enhancement of spontaneous emission in microcavities E. F. Schubert and N. E. J. Hunt; 4. Epitaxy of vertical-cavity lasers R. P. Schneider Jr and Y. H. Young; 5. Fabrication and performance of vertical-cavity surface-emitting lasers Kent D. Choquette and Kent Geib; 6. Polarization related properties of vertical cavity lasers Dmitri Kuksenkov and Henryk Temkin; 7. Visible light emitting vertical cavity lasers Robert L. Thornton; 8. Long-wavelength vertical-cavity lasers Dubrakovo I. Babic, Joachim Piprek and John E. Bowers; 9. Overview of VCSEL applications Richard C. Williamson; 10. Optical interconnection applications and required characteristics Kenichi Kasahara; 11. VCSEL-based fiber-optic data communications Kenneth Hahn and Kirk Giboney; 12. VCSEL-based smart pixels for free space optoelectronic processing C. W. Wilmsen.

  17. Vertical external cavity surface emitting semiconductor lasers

    CERN Document Server

    Holm, M

    2001-01-01

    Active stabilisation showed a relative locked linewidth of approx 3 kHz. Coarse tuning over 7 nm was achieved using a 3-plate birefingent filter plate while fine-tuning using cavity length change allowed tuning over 250 MHz. Vertical external cavity semiconductor lasers have emerged as an interesting technology based on current vertical cavity semiconductor laser knowledge. High power output into a single transverse mode has attracted companies requiring good fibre coupling for telecommunications systems. The structure comprises of a grown semiconductor Bragg reflector topped with a multiple quantum well gain region. This is then included in an external cavity. This device is then optically pumped to promote laser action. Theoretical modelling of AIGaAs based VECSEL structures was undertaken, showing the effect of device design on laser characteristics. A simple 3-mirror cavity was constructed to assess the static characteristics of the structure. Up to 153 mW of output power was achieved in a single transver...

  18. Power coupler kick of the TRIUMF ICM capture cavities

    Science.gov (United States)

    Yan, Fang; E. Laxdal, R.; Zvyagintsev, V.; Yu., Chao; C., Gong; Koscielniak, S.

    2011-06-01

    The TRIUMF Injector CryoModule (ICM) adapted two superconducting single cavities as the capture section for the low injecting energy of 100 keV electrons. Coupler kick induced beam deflection and projected emittance growth are one of the prime concerns of the beam stability, especially at low energies. In low energy applications, the electron velocity changes rapidly inside the cavity, which makes the numerical analysis much more complicated. The commonly used theoretical formulas of the direct integral or the Panofsky-Wenzel theorem is not suitable for the kick calculation of β < 1 electrons. Despite that, the above mentioned kick calculation method doesn't consider injecting electron energy, the beam offset due to the coupler kick may not be negligible because of the low injection energy even if the kick is optimized. Thus the beam dynamics code TRACK is used here for the simulation of the power coupler kick perturbation. The coupler kick can be compensated for by a judicious choice of the coupler position in successive cavities from upstream to downstream. The simulation shows that because of the adiabatic damping by the following superconducting 9-cell cavity, even for the worst orbit distortion case after two capture cavities, the kick is still acceptable at the exit of the ICM after reaching 10 MeV. This paper presents the analysis of the transverse kick and the projected emittance growth induced by the coupler for β < 1 electrons. The simulated results of the TRIUMF ICM capture cavities are described and presented.

  19. Power coupler kick of the TRIUMF ICM capture cavities

    Institute of Scientific and Technical Information of China (English)

    YAN Fang; R.E. Laxdal; V. Zvyagintsev; Yu. Chao; C. Gong; S. Koscielniak

    2011-01-01

    The TRIUMF Injector CryoModule (ICM) adapted two superconducting single cavities as the capture section for the low injecting energy of 100 keV electrons. Coupler kick induced beam deflection and projected emittance growth are one of the prime concerns of the beam stability, especially at low energies. In low energy applications, the electron velocity changes rapidly inside the cavity, which makes the numerical analysis much more complicated. The commonly used theoretical formulas of the direct integral or the Panofsky- Wenzel theorem is not suitable for the kick calculation of β <1 electrons. Despite that, the above mentioned kick calculation method doesn't consider injecting electron energy, the beam offset due to the coupler kick may not be negligible because of the low injection energy even if the kick is optimized. Thus the beam dynamics code TRACK is used here for the simulation of the power coupler kick perturbation. The coupler kick can be compensated for by a judicious choice of the coupler position in successive cavities from upstream to downstream. The simulation shows that because of the adiabatic damping by the following superconducting 9-cell cavity, even for the worst orbit distortion case after two capture cavities, the kick is still acceptable at the exit of the ICM after reaching 10 MeV. This paper presents the analysis of the transverse kick and the projected emittance growth induced by the coupler for β <1 electrons. The simulated results of the TRIUMF ICM capture cavities are described and presented.

  20. LEP copper accelerating cavities

    CERN Multimedia

    Laurent Guiraud

    1999-01-01

    These copper cavities were used to generate the radio frequency electric field that was used to accelerate electrons and positrons around the 27-km Large Electron-Positron (LEP) collider at CERN, which ran from 1989 to 2000. The copper cavities were gradually replaced from 1996 with new superconducting cavities allowing the collision energy to rise from 90 GeV to 200 GeV by mid-1999.

  1. Cavity length below chute aerators

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    It is proved that air entrainment is one of the efficient measures dealing with cavi-tation control for the release works of hydropower projects. There are many factors to be considered in designing a chute aerator. One of the most important factors concerns the cavity length below the aerator,which has outstanding effects on air entrainment against cavitation damage. It is crucial to determine reasonable emergence angle for the calculation of the cavity length. In the present paper the overall effects of structural and hydraulic parameters on the emergence angle of the flow from the aerator were analyzed. Four improved expressions of the emer-gence angle with weight coefficient were investigated through experimental data of 68 points observed from 12 aerators of 6 hydropower projects,of both model and prototype,on the basis of error theory. A method to calculate the cavity length be-low aerators was suggested,which considers overall effects of the above men-tioned parameters. Comparison between the method in this paper and the other five methods of calculating the cavity length showed that the present method is much more reliable than the existing methods while the mean error of the method is less than others.

  2. Cavity length below chute aerators

    Institute of Scientific and Technical Information of China (English)

    WU JianHua; RUAN ShiPing

    2008-01-01

    It is proved that air entrainment is one of the efficient measures dealing with cavitation control for the release works of hydropower projects. There are many factors to be considered in designing a chute aerator. One of the most important factors concerns the cavity length below the aerator, which has outstanding effects on air entrainment against cavitation damage. It is crucial to determine reasonable emergence angle for the calculation of the cavity length. In the present paper the overall effects of structural and hydraulic parameters on the emergence angle of the flow from the aerator were analyzed. Four improved expressions of the emergence angle with weight coefficient were investigated through experimental data of 68 points observed from 12 aerators of 6 hydropower projects, of both model and prototype, on the basis of error theory. A method to calculate the cavity length below aerators was suggested, which considers overall effects of the above mentioned parameters. Comparison between the method in this paper and the other five methods of calculating the cavity length showed that the present method is much more reliable than the existing methods while the mean error of the method is less than others.

  3. Superconducting spoke cavities for high-velocity applications

    Energy Technology Data Exchange (ETDEWEB)

    Hopper, Christopher S. [Old Dominion U.; Delayen, Jean R. [Old Dominion U., JLAB

    2013-10-01

    To date, superconducting spoke cavities have been designed, developed, and tested for particle velocities up to {beta}{sub 0}~0.6, but there is a growing interest in possible applications of multispoke cavities for high-velocity applications. We have explored the design parameter space for low-frequency, high-velocity, double-spoke superconducting cavities in order to determine how each design parameter affects the electromagnetic properties, in particular the surface electromagnetic fields and the shunt impedance. We present detailed design for cavities operating at 325 and 352 MHz and optimized for {beta}{sub 0}~=0.82 and 1.

  4. Accoustic Localization of Breakdown in Radio Frequency Accelerating Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Lane, Peter Gwin [IIT, Chicago

    2016-07-01

    Current designs for muon accelerators require high-gradient radio frequency (RF) cavities to be placed in solenoidal magnetic fields. These fields help contain and efficiently reduce the phase space volume of source muons in order to create a usable muon beam for collider and neutrino experiments. In this context and in general, the use of RF cavities in strong magnetic fields has its challenges. It has been found that placing normal conducting RF cavities in strong magnetic fields reduces the threshold at which RF cavity breakdown occurs. To aid the effort to study RF cavity breakdown in magnetic fields, it would be helpful to have a diagnostic tool which can localize the source of breakdown sparks inside the cavity. These sparks generate thermal shocks to small regions of the inner cavity wall that can be detected and localized using microphones attached to the outer cavity surface. Details on RF cavity sound sources as well as the hardware, software, and algorithms used to localize the source of sound emitted from breakdown thermal shocks are presented. In addition, results from simulations and experiments on three RF cavities, namely the Aluminum Mock Cavity, the High-Pressure Cavity, and the Modular Cavity, are also given. These results demonstrate the validity and effectiveness of the described technique for acoustic localization of breakdown.

  5. Capture cavity cryomodule for quantum beam experiment at KEK superconducting RF test facility

    Science.gov (United States)

    Tsuchiya, K.; Hara, K.; Hayano, H.; Kako, E.; Kojima, Y.; Kondo, Y.; Nakai, H.; Noguchi, S.; Ohuchi, N.; Terashima, A.; Horikoshi, A.; Semba, T.

    2014-01-01

    A capture cavity cryomodule was fabricated and used in a beam line for quantum beam experiments at the Superconducting RF Test Facility (STF) of the High Energy Accelerator Research Organization in Japan. The cryomodule is about 4 m long and contains two nine-cell cavities. The cross section is almost the same as that of the STF cryomodules that were fabricated to develop superconducting RF cavities for the International Linear Collider. An attempt was made to reduce the large deflection of the helium gas return pipe (GRP) that was observed in the STF cryomodules during cool-down and warm-up. This paper briefly describes the structure and cryogenic performance of the captures cavity cryomodule, and also reports the measured displacement of the GRP and the cavity-containing helium vessels during regular operation.

  6. Capture cavity cryomodule for quantum beam experiment at KEK superconducting RF test facility

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, K.; Hara, K.; Hayano, H.; Kako, E.; Kojima, Y.; Kondo, Y.; Nakai, H.; Noguchi, S.; Ohuchi, N.; Terashima, A. [High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki 305-0801 (Japan); Horikoshi, A.; Semba, T. [Hitachi, Ltd., Hitachi Works, Hitachi, Ibaraki 317-8511 (Japan)

    2014-01-29

    A capture cavity cryomodule was fabricated and used in a beam line for quantum beam experiments at the Superconducting RF Test Facility (STF) of the High Energy Accelerator Research Organization in Japan. The cryomodule is about 4 m long and contains two nine-cell cavities. The cross section is almost the same as that of the STF cryomodules that were fabricated to develop superconducting RF cavities for the International Linear Collider. An attempt was made to reduce the large deflection of the helium gas return pipe (GRP) that was observed in the STF cryomodules during cool-down and warm-up. This paper briefly describes the structure and cryogenic performance of the captures cavity cryomodule, and also reports the measured displacement of the GRP and the cavity-containing helium vessels during regular operation.

  7. Free Vibration Analysis of Rectangular Orthotropic Membranes in Large Deflection

    Directory of Open Access Journals (Sweden)

    Zheng Zhou-Lian

    2009-01-01

    Full Text Available This paper reviewed the research on the vibration of orthotropic membrane, which commonly applied in the membrane structural engineering. We applied the large deflection theory of membrane to derive the governing vibration equations of orthotropic membrane, solved it, and obtained the power series formula of nonlinear vibration frequency of rectangular membrane with four edges fixed. The paper gave the computational example and compared the two results from the large deflection theory and the small one, respectively. Results obtained from this paper provide some theoretical foundation for the measurement of pretension by frequency method; meanwhile, the results provide some theoretical foundation for the research of nonlinear vibration of membrane structures and the response solving of membrane structures under dynamic loads.

  8. Jet deflection by very weak guide fields during magnetic reconnection.

    Science.gov (United States)

    Goldman, M V; Lapenta, G; Newman, D L; Markidis, S; Che, H

    2011-09-23

    Previous 2D simulations of reconnection using a standard model of initially antiparallel magnetic fields have detected electron jets outflowing from the x point into the ion outflow exhausts. Associated with these jets are extended "outer electron diffusion regions." New PIC simulations with an ion to electron mass ratio as large as 1836 (an H(+) plasma) now show that the jets are strongly deflected and the outer electron diffusion region is broken up by a very weak out-of-plane magnetic guide field, even though the diffusion rate itself is unchanged. Jet outflow and deflection are interpreted in terms of electron dynamics and are compared to recent measurements of jets in the presence of a small guide field in Earth's magnetosheath.

  9. Estimation of the deflection of the vertical using gravity measurements

    Science.gov (United States)

    Manoussakis, Gerassimos; Korakitis, Romylos; Milas, Paraskevas

    2017-04-01

    We present a method to estimate the deflection of the vertical at a point P on the Earth's physical surface by forming a small network of three points around point P, with known geodetic coordinates (φ, λ, h) and by obtaining gravity measurements at all points. In the first step, the gravity values are used to form the Eötvös matrix of the actual gravity potential W at point P. In the second step, the gravity differences and the components of the Eötvös matrix are used to form a linear system of three algebraic equations with three unknowns, which are the first order partial derivatives of the actual potential W. The solution of the system enables us to determine the components ξ and η of the deflection of the vertical at the chosen point P. Finally, we present a numerical simulation, using several points scattered on a wide area of the Earth's surface.

  10. Deflection of Rotating Symmetric Molecules by Inhomogeneous Fields

    CERN Document Server

    Gershnabel, Erez

    2011-01-01

    We consider deflection of rotating symmetric molecules by inhomogeneous optical and static electric fields, compare results with the case of linear molecules, and find new singularities in the distribution of the scattering angle. Scattering of the prolate/oblate molecules is analyzed in detail, and it is shown that the process can be efficiently controlled by means of short and strong femtosecond laser pulses. In particular, the angular dispersion of the deflected molecules may be dramatically reduced by laser-induced molecular pre-alignment. We first study the problem by using a simple classical model, and then find similar results by means of more sophisticated methods, including the formalism of adiabatic invariants and direct numerical simulation of the Euler-Lagrange equations of motion. The suggested control scheme opens new ways for many applications involving molecular focusing, guiding, and trapping by optical and static fields.

  11. Strong deflection gravitational lensing by a modified Hayward black hole

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Shan-Shan; Xie, Yi [Nanjing University, School of Astronomy and Space Science, Nanjing (China); Nanjing University, Ministry of Education, Key Laboratory of Modern Astronomy and Astrophysics, Nanjing (China)

    2017-05-15

    A modified Hayward black hole is a nonsingular black hole. It is proposed that it would form when the pressure generated by quantum gravity can stop matter's collapse as the matter reaches the Planck density. Strong deflection gravitational lensing occurring nearby its event horizon might provide some clues of these quantum effects in its central core. We investigate observables of the strong deflection lensing, including angular separations, brightness differences and time delays between its relativistic images, and we estimate their values for the supermassive black hole in the Galactic center. We find that it is possible to distinguish the modified Hayward black hole from a Schwarzschild one, but it demands a very high resolution, beyond current stage. (orig.)

  12. A map of UHECRs deflections through the turbulent GMF

    Energy Technology Data Exchange (ETDEWEB)

    Pshirkov, M.S. [Sternberg Astronomical Institute, Lomonosov Moscow State University, Universitetsky Prospekt 13, 119992 Moscow (Russian Federation); Pushchino Radio Astronomy Observatory, 142290 Pushchino (Russian Federation); Institute for Nuclear Research of the Russian Academy of Sciences, 117312 Moscow (Russian Federation); Tinyakov, P.G. [Institute for Nuclear Research of the Russian Academy of Sciences, 117312 Moscow (Russian Federation); Université Libre de Bruxelles, Service de Physique Théorique, CP225, 1050 Brussels (Belgium); Urban, F.R. [Université Libre de Bruxelles, Service de Physique Théorique, CP225, 1050 Brussels (Belgium)

    2014-04-01

    We study the effect of the random part of the Galactic Magnetic Field (GMF) on the propagation of ultra high-energy cosmic rays. We are able to derive a clear and direct relation between the observed variance of rotation measures and the predicted cosmic ray deflections, which puts a solid upper limit of the experimentally observed displacements. Remarkably, this is obtained bypassing entirely the detailed knowledge of the magnetic properties of the turbulent plasma, and that of the electron density variance. Over most of the sky the random deflections for 40 EeV protons do not exceed 1–2°, and can be as large as 5° close to the Galactic plane.

  13. Prediction of Double Layer Grids' Maximum Deflection Using Neural Networks

    Directory of Open Access Journals (Sweden)

    Reza K. Moghadas

    2008-01-01

    Full Text Available Efficient neural networks models are trained to predict the maximum deflection of two-way on two-way grids with variable geometrical parameters (span and height as well as cross-sectional areas of the element groups. Backpropagation (BP and Radial Basis Function (RBF neural networks are employed for the mentioned purpose. The inputs of the neural networks are the length of the spans, L, the height, h and cross-sectional areas of the all groups, A and the outputs are maximum deflections of the corresponding double layer grids, respectively. The numerical results indicate that the RBF neural network is better than BP in terms of training time and performance generality.

  14. Effect of layer length on deflection in sandwich beams

    Science.gov (United States)

    Abbu, Muthanna A.; AL-Ameri, Riyadh

    2017-09-01

    A theoretical study has been carried out on sandwich beams strengthened mechanically by two external steel plates attached to their tension and compression sides with so-called "shear connectors ". This study is based on the individual behaviour of each component of the composite sandwich section (i.e. reinforced concrete beam and upper steel plate and lower steel plate). The approach has been developed to simulate the behaviour of such beams, and is based on neglecting the separation between the three layers; i.e., the deflections are equal in each element through the same section. The differential equations reached were solved analytically. Deflection was calculated by using the approach for several beams, tested in two series, and close agreements were obtained with the experimental values. Furthermore, the interaction efficiency between the three elements in a composite sandwich beam has been considered thoroughly, from which the effect of some parameters, such as plate length upon the behaviour of such beams, were studied.

  15. Design and Numerical Simulation of Two Dimensional Ultra Compact Combustor Model Sections for Experimental Observation of Cavity-Vane Flow Interactions

    Science.gov (United States)

    2005-09-01

    component UHC Unburned hydrocarbons xviii Symbol V Cavity volume y* Wall unit yυ Viscous sub-layer thickness YM Term for contribution of...Emissions. Pollutant species of interest at the combustor exhaust plane include CO, CO2, NOx, and unburned hydrocarbons ( UHC ), while the exhaust level...fraction, and are reported in the form of part-per-million (ppm) for CO, NOx, UHC or percentage of total for CO2, O2. The combustion modeling in FLUENT

  16. Deflection of Resilient Materials for Reduction of Floor Impact Sound

    OpenAIRE

    Jung-Yoon Lee; Jong-Mun Kim

    2014-01-01

    Recently, many residents living in apartment buildings in Korea have been bothered by noise coming from the houses above. In order to reduce noise pollution, communities are increasingly imposing bylaws, including the limitation of floor impact sound, minimum thickness of floors, and floor soundproofing solutions. This research effort focused specifically on the deflection of resilient materials in the floor sound insulation systems of apartment houses. The experimental program involved condu...

  17. A New Possibility for Production of Sub-picosecond X-ray Pulses using a Time Dependent Radio Frequency Orbit Deflection

    Energy Technology Data Exchange (ETDEWEB)

    Zholents, A. A. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-05-01

    It is shown that two radio frequency deflecting cavities with slightly different frequencies can be used to produce time-dependent orbit deflection to a few special electron bunches while keeping the majority of the electron bunches unaffected. These special bunches produce an x-ray pulse in which transverse position or angle, or both, are correlated with time. The x-ray pulses are then shortened, either with an asymmetrically cut crystal that acts as a pulse compressor, or with an angular aperture such as a narrow slit positioned downstream. The implementation of this technique creates a highly flexible environment for synchrotrons in which users of most beamlines will be able to easily select between the x-rays originated by the standard electron bunches and the short x-ray pulses originated by the special electron bunches carrying a time-dependent transverse correlation.

  18. Stiffness and Angular Deflection analysis of Revolute Manipulator

    Directory of Open Access Journals (Sweden)

    Pundru Srinivasa Rao

    2014-03-01

    Full Text Available This paper proposed to determine the Cartesian stiffness matrix and angular deflection analysis of revolute manipulator. The selected manipulator has rigid fixed link, two movable links and two rotary joints with joint stiffness coefficients are taken into account. The kinematic model of revolute joint manipulator has considered as a planar kinematic chain, which is composed by rigid fixed link and two revolute joints with clearance and deformable elements. The calculation of stiffness matrix depends on Jacobian matrix and change of configuration. The rotational joints are modeled as torsion springs with the same stiffness constant. The relative angular deflections are proportional to the actuated torques taken into account. The subject of this paper has to describe a method for stiffness analysis of serial manipulator. In the present work is to derive the stiffness matrix and angular deflection equations in the Robotic manipulator under the consideration of two-link optimum geometry model for rotary joint manipulator. The stiffness values are measured by displacements of its revolute links loaded by force.

  19. Application of photothermal deflection spectroscopy to electrochemical interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Rudnicki, J.D.; McLarnon, F.R.; Cairns, E.J.

    1992-03-01

    This dissertation discusses the theory and practice of Photothermal Deflection Spectroscopy (PDS, which is also known as probe beam deflection spectroscopy, PBDS, probe deflection technique, and mirage effect spectroscopy) with respect to electrochemical systems. Much of the discussion is also relevant to non-electrochemical systems. PDS can measure the optical absorption spectrum of interfaces and concentration gradients in the electrolyte adjacent to the electrode. These measurements can be made on a wide variety of electrode surfaces and can be performed under dynamic conditions. The first three chapters discuss the theory of the phenomena that can be detected by PDS, and the equipment used in a PDS system. A ``secondary gradient technique`` is proposed, which places the probe beam on the back of an electrode. The results of a numerical model yield a method for determining the offset of the probe beam from the electrode surface based on the frequency response of the PDS signal. The origin and control of noise in the PDS signal are discussed. A majority of the signal noise appears to be acoustic in origin. The electrochemical oxidation of platinum is used to demonstrate that PDS has sub-monolayer sensitivity necessary to study interfacial chemistry. The results allow us to propose a two-reaction oxidation mechanism: the platinum is electrochemically oxidized to form platinum dihydroxide and dehydrated by a non-electrochemical second-order reaction. The final chapter discusses the relation of PDS to similar and competing techniques, and considers possibilities for the future of the technique.

  20. Three cavities dielectric wall proton accelerator timing optimization simulation and design%三腔介质壁质子加速器时序优化模拟及设计

    Institute of Scientific and Technical Information of China (English)

    杨超; 夏连胜; 王卫; 刘毅; 谌怡; 叶茂; 张篁; 邓建军

    2016-01-01

    The three cavities dielectric wall proton accelerator is systemically simulated by the self-developed 3D particle simulation software.On this basis,the transit time of protons in three cavities shall be calculated and the timing optimization de-sign between cavities shall be achieved.The impressed voltage peak value is 100 kV.The width at top is 1ns and it is 10 ns at half maximum.The thickness of insulation micro reactor is 2.0 cm.The proton initial energy is 40 keV.The tungsten mesh is added to accelerating electrode.The simulation results are the following:When the voltage lasts 6.5 ns,the H+ which goes into high insulation gradient material shall get a maximum 90.84% acceleration efficiency while passing the first cavity,and the corre-sponding transit time is 5.668 ns.When the voltage triggers in the second cavity 4.5 ns behinds the first cavity,the H+ shall get a maximum 94.77% acceleration efficiency while passing the third cavity,and the corresponding transit time is 3.545 ns.When the voltage triggers in the third cavity 3.0 ns behinds the second cavity,the H+ shall get a maximum 97.30% acceleration effi-ciency while passing the second cavity,and the corresponding transit time is 3.018 ns.The total time of the maximum energy H+transiting the three cavities is 12.231 ns.The acceleration efficiency of total H+ is 94.31%.When the proton beam center enters the first cavity and falls behind the pulse voltage trigger in 6.5 ns,with the delay time between first and second cavities,the sec-ond and third cavities are 4.5 ns and 3.0 ns respectively.The H+ of proton beams whose lengths are 2.5 ns and 4.0 ns shall be accelerated above 90% and 80% respectively.%采用自主研发的三维粒子模拟软件对三腔介质壁加速器进行系统仿真,在此基础上,计算三个腔质子的渡越时间并实现腔体间的时序优化设计.外加电压峰值100 kV,顶宽1 ns,半高宽10 ns,绝缘微堆厚度2.0 cm,质子初始束能40 keV,加速电极添加钨网,模

  1. Development of rebunching cavities at IAP

    CERN Document Server

    Welsch, C P; Schempp, A

    2000-01-01

    A focus of work at IAP has been the development and optimization of spiral loaded cavities since the 1970s [A. Schempp et al, NIM 135, 409 (1976)]. These cavities feature a high efficiency, a compact design and a big variety of possible fields of application. They find use both as bunchers and post accelerators to vary the final energy of the beam. In comparison to other available designs, the advantage of these structures lies in their small size. Furthermore they can easily be tuned to the required resonance frequency by varying the length of the spiral. Due to the small size of the cavities the required budget can also be kept low. Here, two slightly different types of spiral loaded cavities, which were built for the REX-ISOLDE project at CERN and the intensity upgrade program at GSI are being discussed.

  2. Cavity spin optodynamics

    CERN Document Server

    Brahms, N

    2010-01-01

    The dynamics of a large quantum spin coupled parametrically to an optical resonator is treated in analogy with the motion of a cantilever in cavity optomechanics. New spin optodynamic phenonmena are predicted, such as cavity-spin bistability, optodynamic spin-precession frequency shifts, coherent amplification and damping of spin, and the spin optodynamic squeezing of light.

  3. SPS accelerating cavity

    CERN Multimedia

    1980-01-01

    One of the SPS acceleration cavities (200 MHz, travelling wave structure). On the ceiling one sees the coaxial transmission line which feeds the power from the amplifier, located in a surface building above, to the upstream end of the cavity. See 7603195 for more details, 7411032 for the travelling wave structure, and also 8104138, 8302397.

  4. Superconducting cavities for LEP

    CERN Multimedia

    1983-01-01

    Above: a 350 MHz superconducting accelerating cavity in niobium of the type envisaged for accelerating electrons and positrons in later phases of LEP. Below: a small 1 GHz cavity used for investigating the surface problems of superconducting niobium. Albert Insomby stays on the right. See Annual Report 1983 p. 51.

  5. SPS accelerating cavity

    CERN Multimedia

    CERN PhotoLab

    1981-01-01

    One of the SPS accelerating cavities (200 MHz, travelling wave structure). The power that is fed into the upstream end of the cavity is extracted at the downstream end and sent into a dump load. See 7603195 for more details, 7411032 for the travelling wave structure, and also 8011289, 8302397.

  6. An improved small-deflection electromechanical model for piezoelectric bending beam actuators and energy harvesters

    Science.gov (United States)

    Tabesh, Ahmadreza; Fréchette, Luc G.

    2008-10-01

    The analytical model presented in this paper describes the energy conversion mechanism of a piezoelectric beam (bimorph) under small-deflection static and vibrating conditions. The model provides an improved approach to design and analyze the performance of piezoelectric actuators and energy harvesters (sensors). Conventional models assume a linear voltage distribution over the piezoelectric beam thickness, which is shown here to be invalid. The proposed modeling method improves accuracy by using a quadratic voltage distribution. The equivalent capacitance of a beam shows a 40% discrepancy between a conventional model and the proposed model for PZT5A material. This inaccuracy level is not negligible, especially when the design of micro-power electrical energy harvesting is concerned. The method solves simultaneously the solid mechanics and Maxwell's equations with the constitutive equations for piezoelectric materials. The paper also proposes a phasor-based procedure for measuring the damping of a piezoelectric beam. An experimental setup is developed to verify the validity of the model. The experimental results confirm the accuracy of the improved model and also reveal limitations in using models for small deflections.

  7. Comparison Between Two Solutions Based on the Relationship of Load-deflection Character of a Large Deflection Rubber Circular Plate

    Institute of Scientific and Technical Information of China (English)

    段浩; 胡宗武; 杨赪石; 黎佑铭

    2003-01-01

    The rubber circular plate is considered as a kind of membrane. Based on the character that there existsno bending-moment inside a membrane, the geometric behavior of the rubber circular plate in expanding state wasdescribed with the aid of a group of mathematic method. The relationship between deflection and load was attainedby means of calculating stress and strain inside the curved-surface of rubber plate. Meantime, based on Henckymethod, the relationship between deflection and load was attained and considered as the Hencky solution. The dif-ferent results given rise by the two different resolving methods were compared. The deviation results from theHencky method was discussed, and a kind of correcting method was put forward.

  8. The Finite Elements Method (FEM versus traditional Methods (TM, in the estimation of settlement and modulus of soil reaction for foundation slabs design on soils with natural or man-made cavities

    Directory of Open Access Journals (Sweden)

    Escolano-Sánchez, F.

    2015-03-01

    Full Text Available Direct foundations with continuous elements, such as slabs, provide more advantages than direct foundations with isolated elements, such as footings, and deep foundations, such as piles, in the case of soil with natural or man-made cavities. The slabs are usually designed by two-dimensional models which show their shape on the plant, on a lineal elastic support, represented by a modulus of soil reaction. Regarding the settlement estimation, the following article compares the Finite Elements Method (FEM versus the classical Method (CM to select the modulus of soil reaction used to design foundations slabs in sensitive soils and sites with possible cavities or collapses. This analysis includes one of these cavities in the design to evaluate the risk of fail.Las cimentaciones directas con elementos continuos «losas», tienen ventajas sobre las cimentaciones directas con elementos aislados «zapatas» y sobre las cimentaciones profundas «pilotes», frente a la presencia de terrenos problemáticos. Las losas se diseñan de forma habitual con modelos bidimensionales que representan su forma en planta, apoyada en un medio elástico y lineal, representado por un módulo de balasto. En el presente artículo se realiza un análisis comparativo, para la estimación de asientos, entre el Método de Elementos Finitos (FEM y el Método Clásico (MC, para la elección de los módulos de balasto que se utilizan en el diseño de losas de cimentación en terrenos con blandones y cavidades naturales o antrópicas. Este análisis considera el peligro de la presencia de una de estas cavidades dentro de su diseño, de esta forma, el riesgo de fallo puede ser valorado por ambos métodos.

  9. Cavity-enhanced optical detection of carbon nanotube Brownian motion

    CERN Document Server

    Stapfner, S; Hunger, D; Weig, E M; Reichel, J; Favero, I

    2012-01-01

    Optical cavities with small mode volume are well-suited to detect the vibration of sub-wavelength sized objects. Here we employ a fiber-based, high-finesse optical microcavity to detect the Brownian motion of a freely suspended carbon nanotube at room temperature under vacuum. The optical detection resolves deflections of the oscillating tube down to 50pm/Hz^1/2. A full vibrational spectrum of the carbon nanotube is obtained and confirmed by characterization of the same device in a scanning electron microscope. Our work successfully extends the principles of high-sensitivity optomechanical detection to molecular scale nanomechanical systems.

  10. Rapid cavity prototyping using mode matching and globalised scattering matrix

    CERN Document Server

    Shinton, I

    2009-01-01

    Cavity design using traditional mesh based numerical means (such as the finite element or finite difference methods) require large mesh calculations in order to obtain accurate values and cavity optimisation is often not achieved. Here we present a mode matching scheme which utilises a globalised scattering matrix approach that allows cavities with curved surfaces (i.e. cavities with elliptical irises and or equators) to be accurately simulated allowing rapid cavity prototyping and optimisation to be achieved. Results on structures in the CLIC main

  11. Prototype 350 MHz niobium spoke-loaded cavities.

    Energy Technology Data Exchange (ETDEWEB)

    Delayen, J. R.; Kedzie, M.; Mammosser, J.; Piller, C.; Shepard, K. W.

    1999-05-10

    This paper reports the development of 350 MHz superconducting cavities of a spoke-loaded geometry, intended for the velocity range 0.2 < v/c < 0.6. Two prototype single-cell cavities have been designed, one optimized for velocity v/c = 0.4, and the other for v/c = 0.29. Construction of the prototype niobium cavities is nearly complete. Details of the design and construction are discussed, along with the results of cold tests.

  12. Modeling of Electromagnetic Heating in RF Copper Accelerating Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Awida, M. H. [Fermilab; Gonin, I. [Fermilab; Romanov, Romanov [Fermilab; Khabiboulline, T. [Fermilab; Yakovlev, V. [Fermilab

    2016-01-17

    Electromagnetic heating is a critical issue in normal conducting copper RF cavities that are employed in particle accelerators. With several tens to hundreds of kilowatts dissipated RF power, there must be an effective cooling scheme whether it is water or air based or even a combination of both. In this paper we investigate the electromagnetic heating in multiple cavities that were designed at Fermilab exploring how the electromagnetic and thermal analyses are coupled together to properly design the cooling of such cavities.

  13. Design of Hot Runner System of the 144 Cavity PET Bottle Preform Mould Based on Moldflow%基于Moldflow的144腔PET瓶坯模具热流道系统设计

    Institute of Scientific and Technical Information of China (English)

    胡青春; 纪仁敏; 姜晓平

    2013-01-01

    According to the structure requirements for the 144 cavity PET bottle preform mould, this paper designed gating system by the natural balance method and calculated all levels of structure size through the rheological theory in the hot runner gating system, which met production requirements. Designed results were simulated and analyzed by the Moldflow and guaranteed the plastic melt to reach each cavity at the same time. The analysis results showed that the designed hot runner system met the requirements.%针对144腔PET瓶坯模具的结构要求,采用自然平衡法设计浇注系统,运用流变学理论计算出符合生产要求的各级流道结构尺寸,用Moldflow软件对设计结果进行模拟分析,保证塑料熔体同时到达每一个型腔,分析结果表明所设计热流道系统满足要求.

  14. Dissipative structures in optomechanical cavities

    Science.gov (United States)

    Ruiz-Rivas, Joaquín; Navarrete-Benlloch, Carlos; Patera, Giuseppe; Roldán, Eugenio; de Valcárcel, Germán J.

    2016-03-01

    Motivated by the increasing interest in the properties of multimode optomechanical devices, here we study a system in which a driven longitudinal mode of a large-area optical cavity is dispersively coupled to a deformable mechanical element. Two different models naturally appear in such scenario, for which we predict the formation of periodic patterns, localized structures (cavity solitons), and domain walls, among other complex nonlinear phenomena. Further, we propose a realistic design based on intracavity membranes where our models can be studied experimentally. Apart from its relevance to the field of nonlinear optics, the results put forward here are a necessary step towards understanding the quantum properties of optomechanical systems in the multimode regime of both the optical and the mechanical degrees of freedom.

  15. SPS RF Accelerating Cavity

    CERN Multimedia

    1979-01-01

    This picture shows one of the 2 new cavities installed in 1978-1979. The main RF-system of the SPS comprises four cavities: two of 20 m length and two of 16.5 m length. They are all installed in one long straight section (LSS 3). These cavities are of the travelling-wave type operating at a centre frequency of 200.2 MHz. They are wideband, filling time about 700 ns and untuned. The power amplifiers, using tetrodes are installed in a surface building 200 m from the cavities. Initially only two cavities were installed, a third cavity was installed in 1978 and a forth one in 1979. The number of power amplifiers was also increased: to the first 2 MW plant a second 2 MW plant was added and by end 1979 there were 8 500 kW units combined in pairs to feed each of the 4 cavities with up to about 1 MW RF power, resulting in a total accelerating voltage of about 8 MV. See also 7412016X, 7412017X, 7411048X

  16. SPS RF Cavity

    CERN Multimedia

    1975-01-01

    The picture shows one of the two initially installed cavities. The main RF-system of the SPS comprises four cavities: two of 20 m length and two of 16.5 m length. They are all installed in one long straight section (LSS 3). These cavities are of the travelling-wave type operating at a centre frequency of 200.2 MHz. They are wideband, filling time about 700 ns and untuned. The power amplifiers, using tetrodes are installed in a surface building 200 m from the cavities. Initially only two cavities were installed, a third cavity was installed in 1978 and a forth one in 1979. The number of power amplifiers was also gradually increased: by end 1980 there were 8 500 kW units combined in pairs to feed each of the 4 cavities with up to about 1 MW RF power, resulting in a total accelerating voltage of about 8 MV. See also 7412017X, 7411048X, 7505074.

  17. Cusp deflection, infraction and fracture in endodontically treated teeth filled with three temporary filling materials (in vitro

    Directory of Open Access Journals (Sweden)

    Ali Eskandarizade

    2015-12-01

    Full Text Available Aim: the aim of this study was to compare cusp deflection, infraction and fracture in teeth filled with three temporary filling materials. Materials & method: Forty five extracted human premolar teeth were chosen. After root canal therapy and mesio-occluso-distal cavity preparation, samples were randomly divided into three groups , each contained 15 teeth and filled with three temporary filling materials: Cavisol (Golchai-Iran, Coltosol F (Coltene,Swiss and Coltene (Ariadent,Iran. Teeth were kept in normal saline at room temperature and every day the intercuspal distance was measured under stereomicroscope for 20 days. Infractions as well as fractures were also noted. Data were analyzed in SPSS 17 using Repeated measurement ANOVA test to evaluate the intercuspal distance and expansion of each sample every day. Results: Intercuspal distance increased in all three groups but was significantly more in Coltosol F group. On the days 10 and 16 two teeth filled with Coltosol F had cusp fracture. Conclusion: Temporary filling materials have hygroscopic expansion and cause cusp deflection which may lead to cusp fracture, so it is recommended to use them in short period of time.

  18. Cavity-enhanced spectroscopies

    CERN Document Server

    van Zee, Roger

    2003-01-01

    ""Cavity-Enhanced Spectroscopy"" discusses the use of optical resonators and lasers to make sensitive spectroscopic measurements. This volume is written by the researcchers who pioneered these methods. The book reviews both the theory and practice behind these spectroscopic tools and discusses the scientific discoveries uncovered by these techniques. It begins with a chapter on the use of optical resonators for frequency stabilization of lasers, which is followed by in-depth chapters discussing cavity ring-down spectroscopy, frequency-modulated, cavity-enhanced spectroscopy, intracavity spectr

  19. Tuned optical cavity magnetometer

    Science.gov (United States)

    Okandan, Murat; Schwindt, Peter

    2010-11-02

    An atomic magnetometer is disclosed which utilizes an optical cavity formed from a grating and a mirror, with a vapor cell containing an alkali metal vapor located inside the optical cavity. Lasers are used to magnetically polarize the alkali metal vapor and to probe the vapor and generate a diffracted laser beam which can be used to sense a magnetic field. Electrostatic actuators can be used in the magnetometer for positioning of the mirror, or for modulation thereof. Another optical cavity can also be formed from the mirror and a second grating for sensing, adjusting, or stabilizing the position of the mirror.

  20. SPS RF cavity

    CERN Multimedia

    1974-01-01

    The main RF-system of the SPS comprises four cavities: two of 20 m length and two of 16.5 m length. They are all installed in one long straight section (LSS 3). These cavities are of the travelling-wave type operating at a centre frequency of 200.2 MHz. They are wideband, filling time about 700 ns and untuned. A power of up to 790 kW can be supplied to each giving a total accelerating voltage of about 8 MV. The power amplifiers, using tetrodes are installed in a surface building 200 m from the cavities.

  1. An examination of the rheological and mucoadhesive properties of poly(acrylic acid) organogels designed as platforms for local drug delivery to the oral cavity.

    Science.gov (United States)

    Jones, David S; Muldoon, Brendan C O; Woolfson, A David; Sanderson, F Dominic

    2007-10-01

    This study examined the rheological/mucoadhesive properties of poly(acrylic acid) PAA organogels as platforms for drug delivery to the oral cavity. Organogels were prepared using PAA (3%, 5%, 10% w/w) dissolved in ethylene glycol (EG), propylene glycol (PG), 1,3-propylene glycol (1,3-PG), 1,5-propanediol (1,5-PD), polyethylene glycol 400 (PEG 400), or glycerol. All organogels exhibited pseudoplastic flow. The increase in storage (G') and loss (G'') moduli of organogels as a function of frequency was minimal, G'' was greater than G'' (at all frequencies), and the loss tangent properties. Enhanced rheological structuring was associated with organogels prepared using glycerol (in particular) and PEG 400 due to their interaction with adjacent carboxylic acid groups on each chain and on adjacent chains. All organogels (with the exception of 1,5-PD) exhibited greater network structure than aqueous PAA gels. Organogel mucoadhesion increased with polymer concentration. Greatest mucoadhesion was associated with glycerol-based formulations, whereas aqueous PAA gels exhibited the lowest mucoadhesion. The enhanced network structure and the excellent mucoadhesive properties of these organogels, both of which may be engineered through choice of polymer concentration/solvent type, may be clinically useful for the delivery of drugs to the oral cavity.

  2. A model to predict deflection of bevel-tipped active needle advancing in soft tissue.

    Science.gov (United States)

    Datla, Naresh V; Konh, Bardia; Honarvar, Mohammad; Podder, Tarun K; Dicker, Adam P; Yu, Yan; Hutapea, Parsaoran

    2014-03-01

    Active needles are recently being developed to improve steerability and placement accuracy for various medical applications. These active needles can bend during insertion by actuators attached to their bodies. The bending of active needles enables them to be steered away from the critical organs on the way to target and accurately reach target locations previously unachievable with conventional rigid needles. These active needles combined with an asymmetric bevel-tip can further improve their steerability. To optimize the design and to develop accurate path planning and control algorithms, there is a need to develop a tissue-needle interaction model. This work presents an energy-based model that predicts needle deflection of active bevel-tipped needles when inserted into the tissue. This current model was based on an existing energy-based model for bevel-tipped needles, to which work of actuation was included in calculating the system energy. The developed model was validated with needle insertion experiments with a phantom material. The model predicts needle deflection reasonably for higher diameter needles (11.6% error), whereas largest error was observed for the smallest needle diameter (24.7% error).

  3. Effects of varying the through silicon via liners thickness on their hoop stresses and deflections

    Directory of Open Access Journals (Sweden)

    Juma Mary Atieno

    2017-03-01

    Full Text Available Through silicon via (TSV interconnect reliability is a problem in electronic packaging. The authors address the insertion losses, deflections which can result to separation of TSV layers and hoop stresses. These problems are due to different coefficient of thermal expansion between materials. The authors propose a robust methodology for (TSV liners in this paper which in turn solves the reliability problem in (TSV. Silicon dioxide material is used in their paper as a TSV liner. First, they modelled the equivalent TSV circuit in advanced design systems (ADS. The authors then simulated it to obtain the TSV characterisation from which they obtained the S-parameter S21 which represents the insertion losses. Insertion losses have been described with changes in frequencies from 0 to 20 GHz with changes in TSV thickness from 7 to 8 µm. Later two different shapes of the TSV liner; the disc- and rod-shaped are modelled in analysis system 14 software. The two shapes with a radius of 5 µm each and a fixed pressure of 100 µPa developed changes in hoop stresses and deflections when the liners thicknesses are varied from 2 to 3 µm. The disc shape experienced least reliability problems so the authors propose its use in via structures.

  4. Deflection by kinetic impact: Sensitivity to asteroid properties

    Science.gov (United States)

    Bruck Syal, Megan; Michael Owen, J.; Miller, Paul L.

    2016-05-01

    Impacting an asteroid with a spacecraft traveling at high speed delivers an impulsive change in velocity to the body. In certain circumstances, this strategy could be used to deflect a hazardous asteroid, moving its orbital path off of an Earth-impacting course. However, the efficacy of momentum delivery to asteroids by hypervelocity impact is sensitive to both the impact conditions (particularly velocity) and specific characteristics of the target asteroid. Here we numerically model asteroid response to kinetic impactors under a wide range of initial conditions, using an Adaptive Smoothed Particle Hydrodynamics code. Impact velocities spanning 1-30 km/s were investigated, yielding, for a particular set of assumptions about the modeled target material, a power-law dependence consistent with a velocity-scaling exponent of μ = 0.44. Target characteristics including equation of state, strength model, porosity, rotational state, and shape were varied, and corresponding changes in asteroid response were documented. The kinetic-impact momentum-multiplication factor, β, decreases with increasing asteroid cohesion and increasing porosity. Although increased porosity lowers β, larger porosities result in greater deflection velocities, as a consequence of reduced target masses for asteroids of fixed size. Porosity also lowers disruption risk for kinetic impacts near the threshold of disruption. Including fast (P = 2.5 h) and very fast (P = 100 s) rotation did not significantly alter β but did affect the risk of disruption by the impact event. Asteroid shape is found to influence the efficiency of momentum delivery, as local slope conditions can change the orientation of the crater ejecta momentum vector. These results emphasize the need for asteroid characterization studies to bracket the range of target conditions expected at near-Earth asteroids while also highlighting some of the principal uncertainties associated with the kinetic-impact deflection strategy.

  5. Application of photothermal deflection spectroscopy to electrochemical interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Rudnicki, J.D.; McLarnon, F.R.; Cairns, E.J.

    1992-03-01

    This dissertation discusses the theory and practice of Photothermal Deflection Spectroscopy (PDS, which is also known as probe beam deflection spectroscopy, PBDS, probe deflection technique, and mirage effect spectroscopy) with respect to electrochemical systems. Much of the discussion is also relevant to non-electrochemical systems. PDS can measure the optical absorption spectrum of interfaces and concentration gradients in the electrolyte adjacent to the electrode. These measurements can be made on a wide variety of electrode surfaces and can be performed under dynamic conditions. The first three chapters discuss the theory of the phenomena that can be detected by PDS, and the equipment used in a PDS system. A secondary gradient technique'' is proposed, which places the probe beam on the back of an electrode. The results of a numerical model yield a method for determining the offset of the probe beam from the electrode surface based on the frequency response of the PDS signal. The origin and control of noise in the PDS signal are discussed. A majority of the signal noise appears to be acoustic in origin. The electrochemical oxidation of platinum is used to demonstrate that PDS has sub-monolayer sensitivity necessary to study interfacial chemistry. The results allow us to propose a two-reaction oxidation mechanism: the platinum is electrochemically oxidized to form platinum dihydroxide and dehydrated by a non-electrochemical second-order reaction. The final chapter discusses the relation of PDS to similar and competing techniques, and considers possibilities for the future of the technique.

  6. The 2017 Eclipse: Centenary of the Einstein Light Deflection Experiment

    Science.gov (United States)

    Kennefick, Daniel

    2017-01-01

    August 21st, 2017 will see a total eclipse of the Sun visible in many parts of the United States. Coincidentally this date marks the centenary of the first observational attempt to test Einstein's General Theory of Relativity by measuring gravitational deflection of light by the Sun. This was attempted by the Kodaikanal Observatory in India during the conjunction of Regulus with the Sun in daylight on August 21st, 1917. The observation was attempted at the urging of the amateur German-British astronomer A. F. Lindemann, with his son, F. A. Lindemann, a well-known physicist, who later played a significant role as Churchill's science advisor during World War II. A century later Regulus will once again be in conjunction with the Sun, but by a remarkable coincidence, this will occur during a solar eclipse! Efforts will be made to measure the star deflection during the eclipse and the experiment is contrasted with the famous expeditions of 1919 which were the first to actually measure the light deflection, since the 1917 effort did not meet with success. Although in recent decades there have been efforts made to suggest that the 1919 eclipse team, led by Arthur Stanley Eddington and Sir Frank Watson Dyson, over-interpreted their results in favor of Einstein this talk will argue that such claims are wrong-headed. A close study of their data analysis reveals that they had good grounds for the decisions they made and this conclusion is reinforced by comparison with a modern re-analysis of the plates by the Greenwich Observatory conducted in 1977.

  7. Static deflection control of flexible beams by piezo-electric actuators

    Science.gov (United States)

    Baz, A. M.

    1986-01-01

    This study deals with the utilization of piezo-electric actuators in controlling the static deformation of flexible beams. An optimum design procedure is presented to enable the selection of the optimal location, thickness and excitation voltage of the piezo-electric actuators in a way that would minimize the deflection of the beam to which these actuators are bonded. Numerical examples are presented to illustrate the application of the developed optimization procedure in minimizing the structural deformation of beams of different materials when subjected to different loading and end conditions using ceramic or polymeric piezo-electric actuators. The results obtained emphasize the importance of the devised rational procedure in designing beam-actuator systems with minimal elastic distortions.

  8. Circuit QED with 3D cavities

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Edwar; Baust, Alexander; Zhong, Ling; Gross, Rudolf [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany); Physik-Department, TU Muenchen, Garching (Germany); Nanosystems Initiative Munich (NIM), Muenchen (Germany); Anderson, Gustav; Wang, Lujun; Eder, Peter; Fischer, Michael; Goetz, Jan; Haeberlein, Max; Schwarz, Manuel; Wulschner, Karl Friedrich; Deppe, Frank; Fedorov, Kirill; Huebl, Hans; Menzel, Edwin [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany); Physik-Department, TU Muenchen, Garching (Germany); Marx, Achim [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany)

    2015-07-01

    In typical circuit QED systems on-chip superconducting qubits are coupled to integrated coplanar microwave resonators. Due to the planar geometry, the resonators are often a limiting factor regarding the total coherence of the system. Alternatively, similar hybrid systems can be realized using 3D microwave cavities. Here, we present design considerations for the 3D microwave cavity as well as the superconducting transmon qubit. Moreover, we show experimental data of a high purity aluminum cavity demonstrating quality factors above 1.4 .10{sup 6} at the single photon level and a temperature of 50 mK. Our experiments also demonstrate that the quality factor is less dependent on the power compared to planar resonator geometries. Furthermore, we present strategies for tuning both the cavity and the qubit individually.

  9. Spin Rate and Deflection Ratio of a Ping Pong Ball

    Directory of Open Access Journals (Sweden)

    Byung Joon Ahn

    2013-01-01

    Full Text Available To investigate the effects of a spherical object’s spin rate on the curvature of its flight, Ping Pong balls, of varying spin rates, were hit horizontally and recorded from above with a high-speed camera. It was shown that there was a proportional relationship between the ball’s spin rate and deflection ratio. Additionally, using the results of the analyzed data, a coefficient of skin friction of the Ping Pong ball was found to be approximately 0.2 under the specific conditions of this investigation.

  10. Online Estimation of wind turbine blade deflection with UWB signals

    DEFF Research Database (Denmark)

    Jensen, Tobias Lindstrøm; Jakobsen, Morten Lomholt; Østergaard, Jan;

    2015-01-01

    In this paper we use ultra-wideband (UWB) signals for the localization of blade tips on wind turbines. Our approach is to acquire two separate distances to each tip via time-delay estimation, and each tip is then localized by triangulation. We derive an approximate maximum a posteriori (MAP) delay...... estimator exploiting i) contextual prior information and ii) a direct-path approximation. The resulting deflection estimation algorithm is computationally feasible for online usage. Simulation studies are conducted to assess the overall triangulation uncertainty and it is observed that negative correlation...

  11. Direct measurement of Vorticella contraction force by micropipette deflection.

    Science.gov (United States)

    France, Danielle; Tejada, Jonathan; Matsudaira, Paul

    2017-02-01

    The ciliated protozoan Vorticella convallaria is noted for its exceptionally fast adenosine triphosphate-independent cellular contraction, but direct measurements of contractile force have proven difficult given the length scale, speed, and forces involved. We used high-speed video microscopy to image live Vorticella stalled in midcontraction by deflection of an attached micropipette. Stall forces correlate with both distance contracted and the resting stalk length. Estimated isometric forces range from 95 to 177 nanonewtons (nN), or 1.12 nN·μm(-1) of the stalk. Maximum velocity and work are also proportional to distance contracted. These parameters constrain proposed biochemical/physical models of the contractile mechanism.

  12. Angular Dispersion and Deflection Function for Heavy Ion Elastic Scattering

    Institute of Scientific and Technical Information of China (English)

    BAI Zhen; MAO Rui-Shi; YUAN Xiao-Hua; Xu Zhi-Guo; ZHANG Hong-Bin; XU Hua-Gen; QI Hui-Rong; WANG Yue; JIA Fei; WU Li-Jie; DING Xian-Li; WANG Qi; GAO Qi; GAO Hui; LI Song-Lin; LI Jun-Qing; ZHANG Ya-Peng; XIAO Guo-Qing; JIN Gen-Ming; REN Zhong-Zhou; ZHOU Shan-Gui; XU Wang; HAN Jian-Long; Fan Gong-Tao; ZHANG Shuang-Quan; PANG Dan-Yang; SERGEY Yu-Kun; XIAO Zhi-Gang; XU Hu-Shan; SUN Zhi-Yu; HU Zheng-Guo; ZHANG Xue-Ying; WANG Hong-Wei

    2007-01-01

    The differential cross sections for elastic scattering products of17 F on 208 Pb have been measured.The angular dispersion plots of In(dσ/dθ)versus θ2 are obtained from the angular distribution of the elastic scattering differential cross sections.Systematical analysis on the angular dispersion for the available experimental data indicates that there is an angular dispersion turning angle at forward angular range within the grazing angle.This turning angle can be clarified as nuclear rainbow in classical deflection function.The exotic behaviour of the nuclear rainbow angle offers a new probe to investigate the halo and skin phenomena.

  13. The Deflection of Charged Particles in an Electric Dodecapole Field

    Energy Technology Data Exchange (ETDEWEB)

    Seely, D. G.; Chalut, K.; Thompson, J. S.; Kvale, T. J.

    1997-10-10

    The properties of an ion-optical device consisting of twelve long parallel rods placed equidistantly on a circle are briefly reviewed. The use of this device in its dodecapole configuration to deflect ions in a plane perpendicular to the axis of the dodecapole is discussed. Results of trajectory computations made with the SIMION ion-optics computer program demonstrate that the device works remarkably well in separating the constituents of a multiply-charged ion beam. The use of this device to merge an ion beam with an optical beam is proposed.

  14. Wind Turbine Blade Deflection Sensing System Based on UWB Technology

    DEFF Research Database (Denmark)

    Franek, Ondrej; Zhang, Shuai; Jensen, Tobias Lindstrøm

    2016-01-01

    by triangulation. An experimental setup with corner reflector antenna mounted at the tip and horn antennas at the root of a 37.3 m long blade is described. Analyzing the data from the experiment, special attention is given to the propagation aspects of the UWB links, with focus on the multipath effects caused...... by the blade. It is demonstrated that despite the adverse effects of the multipath propagation the ranging accuracy of the system amounts to 1.5 cm, leading to maximum error of deflection 4.5 %....

  15. Evaluating and Minimizing Distributed Cavity Phase Errors in Atomic Clocks

    CERN Document Server

    Li, Ruoxin

    2010-01-01

    We perform 3D finite element calculations of the fields in microwave cavities and analyze the distributed cavity phase errors of atomic clocks that they produce. The fields of cylindrical cavities are treated as an azimuthal Fourier series. Each of the lowest components produces clock errors with unique characteristics that must be assessed to establish a clock's accuracy. We describe the errors and how to evaluate them. We prove that sharp structures in the cavity do not produce large frequency errors, even at moderately high powers, provided the atomic density varies slowly. We model the amplitude and phase imbalances of the feeds. For larger couplings, these can lead to increased phase errors. We show that phase imbalances produce a novel distributed cavity phase error that depends on the cavity detuning. We also design improved cavities by optimizing the geometry and tuning the mode spectrum so that there are negligible phase variations, allowing this source of systematic error to be dramatically reduced.

  16. SPS accelerating cavity

    CERN Multimedia

    1976-01-01

    The SPS started up with 2 accelerating cavities (each consisting of 5 tank sections) in LSS3. They have a 200 MHz travelling wave structure (see 7411032 and 7802190) and 750 kW of power is fed to each of the cavities from a 1 MW tetrode power amplifier, located in a surface building above, via a coaxial transmission line. Clemens Zettler, builder of the SPS RF system, is standing at the side of one of the cavities. In 1978 and 1979 another 2 cavities were added and entered service in 1980. These were part of the intensity improvement programme and served well for the new role of the SPS as proton-antiproton collider. See also 7411032, 8011289, 8104138, 8302397.

  17. accelerating cavity from LEP

    CERN Multimedia

    This is an accelerating cavity from LEP, with a layer of niobium on the inside. Operating at 4.2 degrees above absolute zero, the niobium is superconducting and carries an accelerating field of 6 million volts per metre with negligible losses. Each cavity has a surface of 6 m2. The niobium layer is only 1.2 microns thick, ten times thinner than a hair. Such a large area had never been coated to such a high accuracy. A speck of dust could ruin the performance of the whole cavity so the work had to be done in an extremely clean environment. These challenging requirements pushed European industry to new achievements. 256 of these cavities are now used in LEP to double the energy of the particle beams.

  18. Dental Sealants Prevent Cavities

    Science.gov (United States)

    ... MMWR RSS VitalSigns RSS Error processing SSI file Dental Sealants Prevent Cavities Effective protection for children Language: ... more use of sealants and reimbursement of services. Dental care providers can Apply sealants to children at ...

  19. Hybrid vertical cavity laser

    DEFF Research Database (Denmark)

    Chung, Il-Sug; Mørk, Jesper

    2010-01-01

    A new hybrid vertical cavity laser structure for silicon photonics is suggested and numerically investigated. It incorporates a silicon subwavelength grating as a mirror and a lateral output coupler to a silicon ridge waveguide.......A new hybrid vertical cavity laser structure for silicon photonics is suggested and numerically investigated. It incorporates a silicon subwavelength grating as a mirror and a lateral output coupler to a silicon ridge waveguide....

  20. Effects of Electric and Magnetic Fields on the Performance of a Superconducting Cavity

    Energy Technology Data Exchange (ETDEWEB)

    Gianluigi Ciovati; Peter Kneisel; Jacek Sekutowicz; Waldemar Singer

    2005-05-01

    A special two-cell cavity was designed to obtain surface field distributions suitable for investigation of electric and magnetic field effects on cavity performance. The cavity design and preliminary results were presented in a previous contribution. The bulk niobium cavity was heat-treated in a vacuum furnace at 1250 C to improve thermal conductivity. Three seamless hydroformed Nb/Cu cavities of the same design were fabricated to investigate the role of the electron beam welds located in high field areas. This paper will present RF test results at 2 K for the bulk niobium and one of the seamless cavities.