  1. Non-pharmacological treatment of heart failure: Implantable cardioverter defibrillator (ICD) and cardiac resynchronisation therapy

    NARCIS (Netherlands)

    Van Gelder, I.C.; Smit, M.D.; Nieuwland, W; Van Veldhuisen, D.J.

    2006-01-01

    The non-pharmacological therapy of heart failure, in particular an implantable cardioverter defibrillator (ICD) and cardiac resynchronisation therapy or biventricular stimulation, improves symptoms and survival in patients with heart failure. - An ICD is indicated in many patients with heart failure

  2. Optimizing defibrillation waveforms for ICDs.

    Science.gov (United States)

    Kroll, Mark W; Swerdlow, Charles D

    2007-04-01

    While no simple electrical descriptor provides a good measure of defibrillation efficacy, the waveform parameters that most directly influence defibrillation are voltage and duration. Voltage is a critical parameter for defibrillation because its spatial derivative defines the electrical field that interacts with the heart. Similarly, waveform duration is a critical parameter because the shock interacts with the heart for the duration of the waveform. Shock energy is the most often cited metric of shock strength and an ICD's capacity to defibrillate, but it is not a direct measure of shock effectiveness. Despite the physiological complexities of defibrillation, a simple approach in which the heart is modeled as passive resistor-capacitor (RC) network has proved useful for predicting efficient defibrillation waveforms. The model makes two assumptions: (1) The goal of both a monophasic shock and the first phase of a biphasic shock is to maximize the voltage change in the membrane at the end of the shock for a given stored energy. (2) The goal of the second phase of a biphasic shock is to discharge the membrane back to the zero potential, removing the charge deposited by the first phase. This model predicts that the optimal waveform rises in an exponential upward curve, but such an ascending waveform is difficult to generate efficiently. ICDs use electronically efficient capacitive-discharge waveforms, which require truncation for effective defibrillation. Even with optimal truncation, capacitive-discharge waveforms require more voltage and energy to achieve the same membrane voltage than do square waves and ascending waveforms. In ICDs, the value of the shock output capacitance is a key intermediary in establishing the relationship between stored energy-the key determinant of ICD size-and waveform voltage as a function of time, the key determinant of defibrillation efficacy. The RC model predicts that, for capacitive-discharge waveforms, stored energy is minimized

  3. Cognitive behavioral therapy (CBT) in a Patient with Implantable Cardioverter Defibrillator (ICD) and Posttraumatic stress disorder(PTSD).

    Science.gov (United States)

    Ansari, Sahar; Arbabi, Mohammad

    2014-07-01

    The implantable cardioverter defibrillator (ICD) has currently become the standard treatment for preventing sudden cardiac death. There are some psychological consequences in patients with ICD such as posttraumatic stress disorder (PTSD) after the shocks induced by ICD. This report aimed to present the case of a 54-year-old man with ICD who had developed PTSD; his PTSD was treated, using cognitive-behavioral psychotherapy consisting of relaxation, mindfulness and problem solving techniques. In patients with ICD who are experiencing PTSD using cognitive behavioral interventions may be helpful to reduce their psychological sufferings.

  4. Cognitive behavioral therapy (CBT in a Patient with Implantable Cardioverter Defibrillator (ICD and Posttraumatic stress disorder(PTSD.

    Directory of Open Access Journals (Sweden)

    Sahar Ansari

    2014-09-01

    Full Text Available The implantable cardioverter defibrillator (ICD has currently become the standard treatment for preventing sudden cardiac death. There are some psychological consequences in patients with ICD such as posttraumatic stress disorder (PTSD after the shocks induced by ICD. This report aimed to present the case of a 54-year-old man with ICD who had developed PTSD; his PTSD was treated, using cognitive-behavioral psychotherapy consisting of relaxation, mindfulness and problem solving techniques. In patients with ICD who are experiencing PTSD using cognitive behavioral interventions may be helpful to reduce their psychological sufferings.

  5. Results of ENHANCED Implantable Cardioverter Defibrillator Programming to Reduce Therapies and Improve Quality of Life (from the ENHANCED-ICD Study).

    Science.gov (United States)

    Mastenbroek, Mirjam H; Pedersen, Susanne S; van der Tweel, Ingeborg; Doevendans, Pieter A; Meine, Mathias

    2016-02-15

    Novel implantable cardioverter defibrillator (ICD) discrimination algorithms and programming strategies have significantly reduced the incidence of inappropriate shocks, but there are still gains to be made with respect to reducing appropriate but unnecessary antitachycardia pacing (ATP) and shocks. We examined whether programming a number of intervals to detect (NID) of 60/80 for ventricular tachyarrhythmia (VT)/ventricular fibrillation (VF) detection was safe and the impact of this strategy on (1) adverse events related to ICD shocks and syncopal events; (2) ATPs/shocks; and (3) patient-reported outcomes. The "ENHANCED Implantable Cardioverter Defibrillator programming to reduce therapies and improve quality of life" study (ENHANCED-ICD study) was a prospective, safety-monitoring study enrolling 60 primary and secondary prevention patients at the University Medical Center Utrecht. Patients implanted with any type of ICD with SmartShock technology and aged 18 to 80 years were eligible to participate. In all patients, a prolonged NID 60/80 was programmed. The cycle length for VT/fast VT/VF was 360/330/240 ms, respectively. Programming a NID 60/80 proved safe for ICD patients. Because of the new programming strategy, unnecessary ICD therapy was prevented in 10% of ENHANCED-ICD patients during a median follow-up period of 1.3 years. With respect to patient-reported outcomes, levels of distress were highest and perceived health status lowest at the time of implantation, which both gradually improved during follow-up. In conclusion, the ENHANCED-ICD study demonstrates that programming a NID 60/80 for VT/VF detection is safe for ICD patients and does not negatively impact their quality of life.

  6. The Screen-ICD trial. Screening for anxiety and cognitive therapy intervention for patients with implanted cardioverter defibrillator (ICD)

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Herning, Margrethe; Svendsen, Jesper Hastrup

    2016-01-01

    by Structured Clinical Interview for DSM Disorders (SCID). (3) Investigator-initiated randomised clinical superiority trial with blinded outcome assessment, with 1:1 randomisation to cognitive–behavioural therapy (CBT) performed by a cardiac nurse with CBT training, plus usual care or usual care alone...

  7. The Screen-ICD trial. Screening for anxiety and cognitive therapy intervention for patients with implanted cardioverter defibrillator (ICD)

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Herning, Margrethe; Svendsen, Jesper Hastrup;

    2016-01-01

    by Structured Clinical Interview for DSM Disorders (SCID). (3) Investigator-initiated randomised clinical superiority trial with blinded outcome assessment, with 1:1 randomisation to cognitive–behavioural therapy (CBT) performed by a cardiac nurse with CBT training, plus usual care or usual care alone...

  8. Implantable defibrillator therapy: more than defibrillation...

    NARCIS (Netherlands)

    D.A.M.J. Theuns (Dominic)

    2005-01-01

    textabstractDuring the past 25 years, the implantable cardioverter-defibrillator (ICD) has evolved from the treatment of last resort to the gold standard for patients at high risk for life­threatening ventricular tachyarrhythmias. Patients at high risk include those who survived life-threatening ven

  9. Implantable defibrillator therapy: more than defibrillation...

    NARCIS (Netherlands)

    D.A.M.J. Theuns (Dominic)

    2005-01-01

    textabstractDuring the past 25 years, the implantable cardioverter-defibrillator (ICD) has evolved from the treatment of last resort to the gold standard for patients at high risk for life­threatening ventricular tachyarrhythmias. Patients at high risk include those who survived life-threatening

  10. Living with Your Implantable Cardioverter Defibrillator (ICD)

    Science.gov (United States)

    ... you take and when. Download a printable medication tracker . Learn more about arrhythmia medications in general. Understanding ... and dentists that you have an ICD. Follow activity instructions Follow the restrictions on activity and any ...

  11. Frequent Home Monitoring of ICD Is Effective to Prevent Inappropriate Defibrillator Shock Delivery

    Directory of Open Access Journals (Sweden)

    Paolo Bifulco

    2014-01-01

    Full Text Available Recently, in the context of telemedicine, telemonitoring services are gaining attention. They are offered, for example, to patients with implantable cardioverter defibrillators (ICDs. A major problem associated with ICD therapy is the occurrence of inappropriate shocks which impair patients’ quality of life and may also be arrhythmogenic. The telemonitoring can provide a valid support to intensify followup visits, in order to improve the prevention of inappropriate defibrillator shock, thus enhancing patient safety. Inappropriate shock generally depends on atrial fibrillation, supraventricular tachycardia, and abnormal sensing (such as those caused by electromagnetic interferences. As a practical example, an unusual case of an ICD patient who risked an inappropriate shock while taking a shower is reported. Continuous remote telemonitoring was able to timely warn cardiologist via GSM-SMS, who were able to detect improper sensing examining the intracardiac electrogram via Web. Patient was promptly contacted and warned to not further come in contact with the hydraulic system and any electrical appliance to prevent an inappropriate defibrillator shock. This demonstrates the effectiveness and usefulness of continuous remote telemonitoring in supporting ICD patients.

  12. Influence of diabetes mellitus on inappropriate and appropriate implantable cardioverter-defibrillator therapy and mortality in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) Trial

    DEFF Research Database (Denmark)

    Ruwald, Martin H.; Zareba, Wojciech; Jons, Christian;

    2013-01-01

    The relationship between diabetes mellitus and risk of inappropriate or appropriate therapy in patients receiving an implantable cardioverter-defibrillator (ICD) and resynchronization therapy has not been investigated thoroughly. The effect of innovative ICD programming on therapy delivery in the...

  13. Implantable cardioverter-defibrillator programming and electrical storm: Results of the OBSERVational registry On long-term outcome of ICD patients (OBSERVO-ICD).

    Science.gov (United States)

    Guerra, Federico; Palmisano, Pietro; Dell'Era, Gabriele; Ziacchi, Matteo; Ammendola, Ernesto; Bonelli, Paolo; Patani, Francesca; Cupido, Claudio; Devecchi, Chiara; Accogli, Michele; Occhetta, Eraldo; Santangelo, Lucio; Biffi, Mauro; Boriani, Giuseppe; Capucci, Alessandro

    2016-10-01

    Electrical storm (ES) is defined as 3 or more episodes of ventricular fibrillation (VF) or ventricular tachycardia (VT) within 24 hours and is associated with increased cardiac and all-cause mortality. The purpose of this study was to test whether aggressive implantable cardioverter-defibrillator (ICD) programming can be associated with ES. The OBSERVational registry On long-term outcome of ICD patients (OBSERVO-ICD) is a multicenter, retrospective registry enrolling all consecutive patients undergoing ICD implantation from 2010 to 2012 in 5 Italian high-volume arrhythmia centers. Clinical history and risk factors were collected for all patients, as were ICD therapy-related variables such as detection zones and delays. The total number of arrhythmic episodes and therapies delivered by the ICD were collected through out-of-hospital visits and remote monitoring. The registry enrolled 1319 consecutive patients, of whom 62 (4.7%) experienced at least 1 ES during follow-up (median 39 months). Patients who experienced ES had a significantly lower VF detection zone (P = .002), more frequently had antitachycardia pacing therapies programmed off during capacitor charge (P = .001), and less frequently had an ICD set with delayed therapies for VT zones (P = .042) and VF zone (P = .036). Patients who experienced ES had a significantly higher incidence of death and heart failure-related death compared to patients with no ventricular arrhythmias and patients with unclustered VTs/VFs (P = .025 and P <.001, respectively). Patients with ES had a more aggressive ICD programming setup, including lower VF detection rates, shorter detection times, and no antitachycardia pacing therapies during capacitor charge. This kind of ICD programming potentially could increase the likelihood of ES and the related risk of death. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  14. The dilemma of implantable cardioverter-defibrillator therapy in the geriatric population

    Institute of Scientific and Technical Information of China (English)

    Diana Revenco; James P Morgan; Lana Tsao

    2011-01-01

    Current guidelines for implantable cardioverter-defibrillator(ICD)therapy in heart failure patients were established by multiple device trials;however,very few geriatric patients(patients≥65 years old)were included in these studies.This article explores the controversies of ICD implantation in the geriatric population,management of delivered ICD therapy in this age group,and the end of life care in patients with ICD.

  15. Worldwide experience with a totally subcutaneous implantable defibrillator: Early results from the EFFORTLESS S-ICD registry

    NARCIS (Netherlands)

    P.D. Lambiase (Pier); C.S. Barr (Craig); D.A.M.J. Theuns (Dominic); R.E. Knops (Reinoud); P. Neuzil (Petr); J.B. Johansen (Jens); A.M. Hood (Margaret); S.S. Pedersen (Susanne); S. Kääb (Stefan); F.D. Murgatroyd (Francis); H.L. Reeve (Helen); N. Carter (Nathan); L. Boersma (Lucas)

    2014-01-01

    textabstractAims The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large inte

  16. Worldwide experience with a totally subcutaneous implantable defibrillator: Early results from the EFFORTLESS S-ICD registry

    NARCIS (Netherlands)

    P.D. Lambiase (Pier); C.S. Barr (Craig); D.A.M.J. Theuns (Dominic); R.E. Knops (Reinoud); P. Neuzil (Petr); J.B. Johansen (Jens); A.M. Hood (Margaret); S.S. Pedersen (Susanne); S. Kääb (Stefan); F.D. Murgatroyd (Francis); H.L. Reeve (Helen); N. Carter (Nathan); L. Boersma (Lucas)

    2014-01-01

    textabstractAims The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large

  17. Statins Decrease Oxidative Stress and ICD Therapies

    Directory of Open Access Journals (Sweden)

    Heather L. Bloom

    2010-01-01

    Full Text Available Recent studies demonstrate that statins decrease ventricular arrhythmias in internal cardioverter defibrillator (ICD patients. The mechanism is unknown, but evidence links increased inflammatory and oxidative states with increased arrhythmias. We hypothesized that statin use decreases oxidation. Methods. 304 subjects with ICDs were surveyed for ventricular arrhythmia. Blood was analyzed for derivatives of reactive oxygen species (DROMs and interleukin-6 (IL-6. Results. Subjects included 252 (83% men, 58% on statins, 20% had ventricular arrhythmias. Average age was 63 years and ejection fraction (EF 20%. ICD implant duration was 29 ± 27 months. Use of statins correlated with lower ICD events (r=0.12, P=.02. Subjects on statins had lower hsCRP (5.2 versus 6.3; P=.05 and DROM levels (373 versus 397; P=.03. Other factors, including IL-6 and EF did not differ between statin and nonstatin use, nor did beta-blocker or antiarrhythmic use. Multivariate cross-correlation analysis demonstrated that DROMs, statins, IL-6 and EF were strongly associated with ICD events. Multivariate regression shows DROMs to be the dominant predictor. Conclusion. ICD event rate correlates with DROMs, a measure of lipid peroxides. Use of statins is associated with reduced DROMs and fewer ICD events, suggesting that statins exert their effect through reducing oxidation.

  18. Rationale and design of the PRAETORIAN trial: A Prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter- defibrillator therapy

    OpenAIRE

    Olde Nordkamp, Louise R.A.; Knops, Reinoud; Bardy, Gust; Blaauw, Yuri; Boersma, Lucas; Bos, Johannes; Delnoy, Peter Paul; Pascal, P.F.H.M.; Driessen, Antoine; Groot, Joris; Herrman, J.P.R.; Jordaens, Luc; Kooiman, Kirsten; Maass, Alexander; Meine, Mathias

    2012-01-01

    textabstractBackground: Implantable cardioverter-defibrillators (ICDs) are widely used to prevent fatal outcomes associated with life-threatening arrhythmic episodes in a variety of cardiac diseases. These ICDs rely on transvenous leads for cardiac sensing and defibrillation. A new entirely subcutaneous ICD overcomes problems associated with transvenous leads. However, the role of the subcutaneous ICD as an adjunctive or primary therapy in patients at risk for sudden cardiac death is unclear....

  19. Monitoring treatment expectations in patients with an implantable cardioverter-defibrillator using the EXPECT-ICD scale

    NARCIS (Netherlands)

    Habibovic, M.; Pedersen, S.S.; van den Broek, K.C.; Denollet, J.

    2014-01-01

    Aims Patient treatment expectations may affect cardiac outcomes; however, till date, no validated instruments have been developed to monitor treatment expectations in patients with an implantable cardioverter-defibrillator (ICD). This study evaluates the predictive value of the newly developed

  20. Impact of new X-ray technology on patient dose in pacemaker and implantable cardioverter defibrillator (ICD) implantations.

    Science.gov (United States)

    van Dijk, Joris D; Ottervanger, Jan Paul; Delnoy, Peter Paul H M; Lagerweij, Martine C M; Knollema, Siert; Slump, Cornelis H; Jager, Pieter L

    2017-01-01

    New X-ray technology providing new image processing techniques may reduce radiation exposure. The aim of this study was to quantify this radiation exposure reduction for patients during pacemaker and implantable cardioverter defibrillator (ICD) implantation. In this retrospective study, 1185 consecutive patients who had undergone de novo pacemaker or ICD implantation during a 2-year period were included. All implantations in the first year were performed using the reference technology (Allura Xper), whereas in the second year, the new X-ray technology (AlluraClarity) was used. Radiation exposure, expressed as the dose area product (DAP), was compared between the two time periods to determine the radiation exposure reduction for pacemaker and ICD implantations without cardiac resynchronization therapy (CRT) and with CRT. Procedure duration and contrast volume were used as measures to compare complexity and image quality. The study population consisted of 591 patients who had undergone an implantation using the reference technology, and 594 patients with the new X-ray technology. The two groups did not differ in age, gender, or body mass index. The DAP decreased with 69 % from 16.4 ± 18.5 to 5.2 ± 6.6 Gy cm(2) for the non-CRT implantations (p pacemaker and ICD implantation while image quality was unaffected.

  1. Outcomes in African-Americans Undergoing Cardioverter Defibrillators Implantation for Primary Prevention of Sudden Cardiac Death: Findings from The Prospective Observational Study of Implantable Cardioverter-Defibrillators (PROSE-ICD)

    Science.gov (United States)

    Zhang, Yiyi; Kennedy, Robert; Blasco-Colmenares, Elena; Butcher, Barbara; Norgard, Sanaz; Eldadah, Zayd; Dickfeld, Timm; Ellenbogen, Kenneth A.; Marine, Joseph E.; Guallar, Eliseo; Tomaselli, Gordon F.; Cheng, Alan

    2014-01-01

    Background Implantable cardioverter defibrillators (ICDs) reduce the risk of death in patients with left ventricular dysfunction. Little is known regarding the benefit of this therapy in African-Americans (AA). Objective To determine the association between African-American race and outcomes in a cohort of primary prevention cardioverter defibrillators (ICD) patients. Methods We conducted a prospective cohort study of patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary endpoint was appropriate ICD shock defined as a shock for rapid ventricular tachyarrhythmias. The secondary endpoint was all-cause mortality. Results There were 1,189 patients (447 AAs and 712 non-AAs) enrolled. Over a median follow-up of 5.1 years, a total of 137 patients experienced an appropriate ICD shock, and 343 died (294 of whom died without receiving an appropriate ICD shock). The multivariate adjusted hazard ratios (95% CI) comparing AAs vs. non-AAs were 1.24 (0.96 to 1.59) for all-cause mortality, 1.33 (1.02, 1.74) for all-cause mortality without receiving appropriate ICD shock, and 0.78 (0.51, 1.19) for appropriate ICD shock. Ejection fraction, diabetes, and hypertension appeared to explain 24.1% (10.1 to 69.5%), 18.7% (5.3 to 58.0%), and 13.6% (3.8 to 53.6%) of the excess risk of mortality in AAs, with a large proportion of the mortality difference remains unexplained. Conclusions In patients with primary prevention ICDs, AAs had an increased risk of dying without receiving an appropriate ICD shock compared to non-AAs. PMID:24793459

  2. Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators.

    Science.gov (United States)

    Alam, Mian Bilal; Munir, Muhammad Bilal; Rattan, Rohit; Flanigan, Susan; Adelstein, Evan; Jain, Sandeep; Saba, Samir

    2014-02-01

    Cardiac resynchronization therapy (CRT) implantable cardioverter defibrillators (ICDs) deliver high burden ventricular pacing to heart failure patients, which has a significant effect on battery longevity. The aim of this study was to investigate whether battery longevity is comparable for CRT-ICDs from different manufacturers in a contemporary cohort of patients. All the CRT-ICDs implanted at our institution from 1 January 2008 to 31 December 2010 were included in this analysis. Baseline demographic and clinical data were collected on all patients using the electronic medical record. Detailed device information was collected on all patients from scanned device printouts obtained during routine follow-up. The primary endpoint was device replacement for battery reaching the elective replacement indicator (ERI). A total of 646 patients (age 69 ± 13 years), implanted with CRT-ICDs (Boston Scientific 173, Medtronic 416, and St Jude Medical 57) were included in this analysis. During 2.7 ± 1.5 years follow-up, 113 (17%) devices had reached ERI (Boston scientific 4%, Medtronic 25%, and St Jude Medical 7%, P battery was significantly worse for Medtronic devices compared with devices from other manufacturers (94% for Boston scientific, 67% for Medtronic, and 92% for St Jude Medical, P battery longevity by manufacturer was independent of pacing burden, lead parameters, and burden of ICD therapy. There are significant discrepancies in CRT-ICD battery longevity by manufacturer. These data have important implications on clinical practice and patient outcomes.

  3. Inappropriate implantable cardioverter defibrillator shock from a transcutaneous muscle stimulation device therapy.

    Science.gov (United States)

    Siu, Chung-Wah; Tse, Hung-Fat; Lau, Chu-Pak

    2005-06-01

    Inappropriate shock from implantable cardioverter defibrillator (ICD) may result from external electromagnetic interference (EMI), especially for unipolar ventricle sensing. Previous case reports and small in-vitro safety study suggested that endocardial bipolar lead system may be immune from EMI resulting from transcutaneous electrical neuromuscle stimulation (TENS) therapy. This report presents an unusual case of inappropriate discharge in a patient with ICD of endocardial bipolar lead system, receiving TENS from a commercially available device.

  4. Attitudes towards implantable cardioverter-defibrillator therapy: a national survey in Danish health-care professionals

    DEFF Research Database (Denmark)

    Johansen, Jens B; Mortensen, Peter T; Videbæk, Regitze

    2011-01-01

    Aims The aim of this study was to examine health-care professionals attitudes towards implantable cardioverter-defibrillator (ICD) therapy and issues discussed with patients. Methods and results Survey of 209 health-care professionals providing specialized treatment and care of ICD patients......-physicians. Physicians were less likely to believe that their personal attitude towards ICD treatment has no influence on how they deal professionally with patients (27.8 vs. 43.6%; P = 0.04). Physicians and non-physicians were equally positive towards ICD therapy as primary prophylaxis in ischaemic cardiomyopathy (87...... discussing ICD treatment with candidate patients. At the same time, physicians are more aware that their attitude towards ICD treatment may influence how they deal professionally with patients compared with non-physicians....

  5. The Effect of ICD Programming on Inappropriate and Appropriate ICD Therapies in Ischemic and Nonischemic Cardiomyopathy

    DEFF Research Database (Denmark)

    Sedláček, Kamil; Ruwald, Anne-Christine; Kutyifa, Valentina;

    2015-01-01

    INTRODUCTION: The MADIT-RIT trial demonstrated reduction of inappropriate and appropriate ICD therapies and mortality by high-rate cut-off and 60-second-delayed VT therapy ICD programming in patients with a primary prophylactic ICD indication. The aim of this analysis was to study effects of MADIT......-RIT ICD programming in patients with ischemic and nonischemic cardiomyopathy. METHODS AND RESULTS: First and total occurrences of both inappropriate and appropriate ICD therapies were analyzed by multivariate Cox models in 791 (53%) patients with ischemic and 707 (47%) patients with nonischemic......-rate cut-off (arm B) and delayed VT therapy ICD programming (arm C) compared with conventional (arm A) ICD programming were associated with a significant risk reduction of first inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy (HR range 0.11-0.34, P

  6. Optimal Implantable Cardioverter Defibrillator Programming.

    Science.gov (United States)

    Shah, Bindi K

    Optimal programming of implantable cardioverter defibrillators (ICDs) is essential to appropriately treat ventricular tachyarrhythmias and to avoid unnecessary and inappropriate shocks. There have been a series of large clinical trials evaluating tailored programming of ICDs. We reviewed the clinical trials evaluating ICD therapies and detection, and the consensus statement on ICD programming. In doing so, we found that prolonged ICD detection times, higher rate cutoffs, and antitachycardia pacing (ATP) programming decreases inappropriate and painful therapies in a primary prevention population. The use of supraventricular tachyarrhythmia discriminators can also decrease inappropriate shocks. Tailored ICD programming using the knowledge gained from recent ICD trials can decrease inappropriate and unnecessary ICD therapies and decrease mortality.

  7. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients - Results from the PREPARE (Primary Prevention Parameters Evaluation) study

    NARCIS (Netherlands)

    Wilkoff, Bruce L.; Williamson, Brian D.; Stern, Richard S.; Moore, Stephen L.; Lu, Fei; Lee, Sung W.; Birgersdotter-Green, Ulrika M.; Wathen, Mark S.; Van Gelder, Isabelle C.; Heubner, Brooke M.; Brown, Mark L.; Holloman, Keith K.

    2008-01-01

    Objectives Our purpose was to demonstrate that strategically chosen implantable cardioverter-defibrillator (ICD) ventricular tachycardia (VT) or ventricular fibrillation (VF) detection and therapy parameters can reduce the combined incidence of device-delivered shocks, arrhythmic syncope, and untrea

  8. The use of guideline recommended beta-blocker therapy in primary prevention implantable cardioverter defibrillator patients

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine; Gislason, Gunnar Hilmar; Vinther, Michael

    2017-01-01

    Aims: We aimed to examine the use of guideline recommended beta-blocker therapy prior to and after primary prevention implantable cardioverter defibrillator (ICD) implantation in a 'real-life' setting. Methods and results: From the Danish Pacemaker and ICD Registry we identified all 1st-time prim......Aims: We aimed to examine the use of guideline recommended beta-blocker therapy prior to and after primary prevention implantable cardioverter defibrillator (ICD) implantation in a 'real-life' setting. Methods and results: From the Danish Pacemaker and ICD Registry we identified all 1st......-time primary prevention ICD and cardiac resynchronization therapy defibrillator (CRT-D) implantations in Denmark from 2007-12 (n = 2935). Use of beta-blocker, type and dose was acquired through the Danish Prescription Registry. According to guideline recommendations, we defined target daily doses as ≥50 mg...... carvedilol and ≥200 mg metoprolol. Prior to implantation 2427 of 2935 (83%) patients received beta-blocker therapy, with 2166 patients (89%) having initiated treatment 3 months or more prior to implantation. The majority of patients was prescribed carvedilol (52%) or metoprolol (41%). Patients on carvedilol...

  9. The effect of intermittent atrial tachyarrhythmia on heart failure or death in cardiac resynchronization therapy with defibrillator versus implantable cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine; Pietrasik, Grzegorz; Goldenberg, Ilan;

    2014-01-01

    OBJECTIVES: This study aimed to investigate the effect of both history of intermittent atrial tachyarrhythmias (IAT) and in-trial IAT on the risk of heart failure (HF) or death comparing cardiac resynchronization therapy with defibrillator (CRT-D) to implantable cardioverter-defibrillator (ICD......, respectively, a history of IAT at baseline and time-dependent development of in-trial IAT during follow-up in 1,264 patients with LBBB enrolled in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study. RESULTS: The overall beneficial effect of CRT...... of in-trial atrial tachyarrhythmias. (MADIT-CRT: Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy; NCT00180271)....

  10. Methodological limitations of psychosocial interventions in patients with an implantable cardioverter-defibrillator (ICD A systematic review

    Directory of Open Access Journals (Sweden)

    Ockene Ira S

    2009-12-01

    Full Text Available Abstract Background Despite the potentially life-saving benefits of the implantable cardioverter-defibrillator (ICD, a significant group of patients experiences emotional distress after ICD implantation. Different psychosocial interventions have been employed to improve this condition, but previous reviews have suggested that methodological issues may limit the validity of such interventions. Aim: To review the methodology of previously published studies of psychosocial interventions in ICD patients, according to CONSORT statement guidelines for non-pharmacological interventions, and provide recommendations for future research. Methods We electronically searched the PubMed, PsycInfo and Cochrane databases. To be included, studies needed to be published in a peer-reviewed journal between 1980 and 2008, to involve a human population aged 18+ years and to have an experimental design. Results Twelve studies met the eligibility criteria. Samples were generally small. Interventions were very heterogeneous; most studies used cognitive behavioural therapy (CBT and exercise programs either as unique interventions or as part of a multi-component program. Overall, studies showed a favourable effect on anxiety (6/9 and depression (4/8. CBT appeared to be the most effective intervention. There was no effect on the number of shocks and arrhythmic events, probably because studies were not powered to detect such an effect. Physical functioning improved in the three studies evaluating this outcome. Lack of information about the indication for ICD implantation (primary vs. secondary prevention, limited or no information regarding use of anti-arrhythmic (9/12 and psychotropic (10/12 treatment, lack of assessments of providers' treatment fidelity (12/12 and patients' adherence to the intervention (11/12 were the most common methodological limitations. Conclusions Overall, this review supports preliminary evidence of a positive effect of psychosocial interventions

  11. Cost-Effectiveness of Adding Cardiac Resynchronization Therapy to an Implantable Cardioverter-Defibrillator Among Patients With Mild Heart Failure

    DEFF Research Database (Denmark)

    Woo, Christopher Y; Strandberg, Erika J; Schmiegelow, Michelle D;

    2015-01-01

    BACKGROUND: Cardiac resynchronization therapy (CRT) reduces mortality and heart failure hospitalizations in patients with mild heart failure. OBJECTIVE: To estimate the cost-effectiveness of adding CRT to an implantable cardioverter-defibrillator (CRT-D) compared with implantable cardioverter......-defibrillator (ICD) alone among patients with left ventricular systolic dysfunction, prolonged intraventricular conduction, and mild heart failure. DESIGN: Markov decision model. DATA SOURCES: Clinical trials, clinical registries, claims data from Centers for Medicare & Medicaid Services, and Centers for Disease...

  12. Single-coil and dual-coil defibrillator leads and association with clinical outcomes in a complete Danish nationwide ICD cohort

    DEFF Research Database (Denmark)

    Larsen, Jacob M; Hjortshøj, Søren P; Nielsen, Jens C;

    2016-01-01

    BACKGROUND: The best choice of defibrillator lead in patients with routine implantable cardioverter-defibrillator (ICD) is not settled. Traditionally, most physicians prefer dual-coil leads but the use of single-coil leads is increasing. OBJECTIVE: The purpose of this study was to compare clinical...... outcomes in patients with single- and dual-coil leads. METHODS: All 4769 Danish patients 18 years or older with first-time ICD implants from 2007 to 2011 were included from the Danish Pacemaker and ICD Register. Defibrillator leads were 38.9% single-coil leads and 61.1% dual-coil leads. The primary end...... point was all-cause mortality. Secondary end points were lowest successful energy at implant defibrillation testing, first shock failure in spontaneous arrhythmias, structural lead failure, and lead extraction outcomes. RESULTS: Single-coil leads were associated with lower all-cause mortality...

  13. Implantable defibrillators versus medical therapy for cardiac channelopathies.

    Science.gov (United States)

    McNamara, David A; Goldberger, Jeffrey J; Berendsen, Mark A; Huffman, Mark D

    2015-10-07

    Sudden cardiac death is a significant cause of mortality in both the US and globally. However, 5% to 15% of people with sudden cardiac death have no structural abnormalities, and most of these events are attributed to underlying cardiac ion channelopathies. Rates of cardiac ion channelopathy diagnosis are increasing. However, the optimal treatment for such people is poorly understood and current guidelines rely primarily on expert opinion. To compare the effect of implantable cardioverter defibrillators (ICD) with antiarrhythmic drugs or usual care in reducing the risk of all-cause mortality, fatal and non-fatal cardiovascular events, and adverse events in people with cardiac ion channelopathies. We searched the Cochrane Central Register of Controlled Trials (CENTRAL, 2015, Issue 6), EMBASE, MEDLINE, Conference Proceedings Citation Index - Science (CPCI-S), ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) in July 2015. We applied no language restrictions. We included all randomized controlled trials of people aged 18 years and older with ion channelopathies, including congenital long QT syndrome, congenital short QT syndrome, Brugada syndrome, or catecholaminergic polymorphic ventricular tachycardia. Participants must have been randomized to ICD implantation and compared to antiarrhythmic drug therapy or usual care. Two authors independently selected studies for inclusion and extracted the data. We included all-cause mortality, fatal and non-fatal cardiovascular events, and adverse events for our primary outcome analyses and non-fatal cardiovascular events, rates of inappropriate ICD firing, quality of life, and cost for our secondary outcome analyses. We calculated risk ratios (RR) and associated 95% confidence intervals (CIs) for dichotomous outcomes, both for independent and pooled study analyses. From the 468 references identified after removing duplicates, we found two trials comprising 86

  14. Canadian Registry of ICD Implant Testing procedures (CREDIT): current practice, risks, and costs of intraoperative defibrillation testing.

    Science.gov (United States)

    Healey, Jeff S; Dorian, Paul; Mitchell, L Brent; Talajic, Mario; Philippon, Francois; Simpson, Chris; Yee, Raymond; Morillo, Carlos A; Lamy, Andre; Basta, Magdy; Birnie, David H; Wang, Xiaoyin; Nair, Girish M; Crystal, Eugene; Kerr, Charles R; Connolly, Stuart J

    2010-02-01

    There is uncertainty about the proper role of defibrillation testing (DT) at the time of implantable cardioverter defibrillator (ICD) insertion. A prospective registry was conducted at 13 sites in Canada between January 2006 and October 2007. To document the details of DT, the reasons for not conducting DT, and the costs and complications associated with DT. DT was conducted at implantation in 230 of 361 patients (64%). DT was more likely to be conducted for new implants compared with impulse generator replacements (71% vs 32%, P = 0.0001), but was similar for primary and secondary prevention indications (64% vs 63%, P = NS). Among patients not having DT, the reason(s) given were: considered unnecessary (44%); considered unsafe, mainly due to persistent atrial fibrillation (37%); lack of an anesthetist (20%); and, patient or physician preference (6%). When performed, DT consisted of a single successful shock > or = 10J below maximum device output in 65% of cases. A 10J safety-margin was met by 97% of patients, requiring system modification in 2.3%. Major perioperative complications occurred in 4.4% of patients having DT versus 6.6% of patients not having DT (P = NS). ICD insertion was $844 more expensive for patients having DT (P = 0.16), largely due to increased costs ($28,017 vs $24,545) among patients having impulse generator replacement (P = 0.02). DT was not performed in a third of ICD implants, usually due to a perceived lack of need or relative contraindication.

  15. Mechanical dispersion and global longitudinal strain by speckle tracking echocardiography: Predictors of appropriate implantable cardioverter defibrillator therapy in hypertrophic cardiomyopathy.

    Science.gov (United States)

    Candan, Ozkan; Gecmen, Cetin; Bayam, Emrah; Guner, Ahmet; Celik, Mehmet; Doğan, Cem

    2017-06-01

    In this study, we investigated whether mechanical dispersion which reflects electrical abnormality and other echocardiographic and clinic parameters predict appropriate ICD shock in patients undergone ICD implantation for hypertrophic cardiomyopathy. Sixty-three patients who received ICD implantation for primary or secondary prevention were included in the study. Patients' clinical, electrocardiographic, 2D classic, and speckle tracking echocardiographic data were collected. Mechanical dispersion was defined as the standard deviation of time to peak negative strain in 18 left ventricular segments. Appropriate ICD therapy was defined as cardioversion or defibrillation due to ventricular tachycardia or fibrillation. Patients were divided into two groups as occurrence or the absence of appropriate ICD therapy. A total of 17 (26.9%) patients were observed to have an appropriate ICD therapy during follow-up periods. In patients who performed appropriate ICD therapy, a larger left atrial volume index, higher sudden cardiac death (SCD)-Risk Score, longer mechanical dispersion, and decreased global longitudinal peak strain (GLPS) were observed. In multivariate logistic regression analysis, including (GLPS, mechanical dispersion, LAVi, and SCD-Risk Score) was used to determine independent predictors of occurrence of appropriate ICD therapy during the follow-up. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be independent predictors of occurrence of appropriate ICD therapy. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be predictive for appropriate ICD therapy in patients receiving ICD implantation. Readily measurable mechanical dispersion and GLPS could be helpful to distinguish patients at high risk who could optimally benefit from ICD therapy. © 2017, Wiley Periodicals, Inc.

  16. Erfahrung mit der Extraktion von transvenösen Kardioverter-Defibrillator (ICD Sonden

    Directory of Open Access Journals (Sweden)

    Dörnberger V

    1999-01-01

    Full Text Available Die ICD-Therapie ist ein bewährtes Verfahren zur Behandlung lebensbedrohlicher ventrikulärer Herzrhythmusstörungen. Defekte der komplex aufgebauten transvenösen Sondensysteme sind beschrieben. Meist ist eine komplette Entfernung defekter Sonden sinnvoll. Wir berichten über unsere Erfahrung mit der Entfernung von 13 transvenösen Elektrodensystemen. In 7 Fällen handelt es sich um eine Endotak C 0072 Sonde (CPI/Guidant und in 6 Fällen um eine Medtronic Transvene 6936 Elektrode. Das Sondenalter zum Zeitpunkt der Extraktion lag zwischen 1,5 und 77,6 Monaten (Mittelwert 36,3 ± 18. Als Extraktionshilfen wurden das VascoExtor Stylet S (Vascomed in 6 Fällen und das Byrd Locking-Stylet 0.017 (0.018 inches (Cook in 4 Fällen verwendet. Alle Extraktionen erfolgten unter transösophagealem Echokardiographie-Monitoring (TEE und Herz-Lungenmaschinen-Bereitschaft (HLM. Ohne Dilatations-Sheath war eine Extraktion nur innerhalb der ersten 3 Monate nach Implantation möglich (n = 3. Ein besonderes Problem stellt der im Vergleich zum Sondenkörper größere Durchmesser der Schockwendel dar, da die Sonde im Verlauf von einem Bindegewebsmantel fest umschlossen und mit der Venenwand verwachsen ist. Mit dem Byrd Dilatator-Schleusenset 10,0 Fr, 11,5 Fr und 13,0 Fr war in allen Fällen eine Lösung von der Venenwand möglich. Eine Extraktion einer Sonde (Medtronic Transvene war nach auswärtigen Vorversuchen mit Zerstörung der inneren Wendel nicht mehr möglich. In einem weiteren Fall konnten zwar die venösen Wandadhäsionen gelöst werden, die distale Schockwendel war jedoch in voller Länge mit dem Endokard verwachsen und konnte nur in einer offenen Herzoperation entfernt werden. In keinem Fall kam es zu einem bedeutsamen Perikarderguß. Kein Patient verstarb in Folge der Sondenextraktion. Zusammenfassend ist die Extraktion von ICD Sonden auch lange nach Implantation möglich. Trotz unserer relativ guten Erfahrung mit der Extraktion von ICD Sonden sollte

  17. Economic impact of longer battery life of cardiac resynchronization therapy defibrillators in Sweden

    Directory of Open Access Journals (Sweden)

    Gadler F

    2016-10-01

    Full Text Available Fredrik Gadler,1 Yao Ding,2 Nathalie Verin,3 Martin Bergius,4 Jeffrey D Miller,5 Gregory M Lenhart,5 Mason W Russell5 1Department of Cardiology, Karolinska University Hospital, Stockholm, Sweden; 2Truven Health Analytics, an IBM Company, Bethesda, MD, USA; 3Boston Scientific Corporation, Hemel Hempstead, Hertfordshire, UK; 4Boston Scientific Nordic AB, Helsingborg, Sweden; 5Truven Health Analytics, an IBM Company, Cambridge, MA, USA Objective: The objective of this study was to quantify the impact that longer battery life of cardiac resynchronization therapy defibrillator (CRT-D devices has on reducing the number of device replacements and associated costs of these replacements from a Swedish health care system perspective.Methods: An economic model based on real-world published data was developed to estimate cost savings and avoided device replacements for CRT-Ds with longer battery life compared with devices with industry-standard battery life expectancy. Base-case comparisons were performed among CRT-Ds of three manufacturers – Boston Scientific Corporation, St. Jude Medical, and Medtronic – over a 6-year time horizon, as per the available clinical data. As a sensitivity analysis, we evaluated CRT-Ds as well as single-chamber implantable cardioverter defibrillator (ICD-VR and dual-chamber implantable cardioverter defibrillator (ICD-DR devices over a longer 10-year period. All costs were in 2015 Swedish Krona (SEK discounted at 3% per annum.Results: Base-case analysis results show that up to 603 replacements and up to SEK 60.4 million cumulative-associated costs could be avoided over 6 years by using devices with extended ­battery life. The pattern of savings over time suggests that savings are modest initially but increase rapidly beginning in the third year of follow-up with each year’s cumulative savings two to three times the previous year. Evaluating CRT-D, ICD-VR, and ICD-DR devices together over a longer 10-year period, the

  18. OVERSENSING AS A CAUSE OF INAPPROPRIATE IMPLANTABLE CARDIOVERTER- DEFIBRILLATOR THERAPY - CASE REPORT

    Directory of Open Access Journals (Sweden)

    Tomislav Kostić

    2013-12-01

    Full Text Available Technology development in the recent years has enabled that both prevention and treatment of life-threatening heart rhythm disorders are managed by implantable cardioverter-defibrillators. Clinical studies have confirmed the advantage of this type of therapy in the prevention of sudden cardiac death in the recent years, so the use of ICDs has became a clinical routine. Rarely functional disturbances of those devices could be seen as undetected malignant arrhythmias (undersensing or false detection of a normal heart rhythm (oversensing. Patient N.S. aged 67 years was admitted to Cardiology Clinic, Clinical Center Niš because of inappropriate sequential therapy of implantable cardioverter-defibrillator (ICD (12 shocks were delivered within 48 hours before admission. ICD pacemaker was implanted four years before the admission due to dilated cardiomyopathy (LVEF 25%. Based on a detailed analysis of the device’s parameters the rapid increase in ventricular lead impedance was established (it was > 3000Ω; and the normal range is 250-2000 Ω. It was found that oversensing was the cause of sequential shocks delivery with energy of 35 J. The damaged lead of the ICD detected false signals as VF (ventricular fibrillation and applied therapy. On the third day of hospitalization, the patient received an ICD Medtronic Maximo II device with the active electrode Medtronic Sprint Quattro 6947 but the left atrial electrode was not displaced. Prophylactic antibiotic therapy was given and patient was discharged 5 days after implantation. After one month at the control visit device parameters were satisfactory, the sensing function was appropriate with good impedance of the lead. Special feature of these devices is the need for individual programming, tailored to each patient, so it is necessary for a center that performs the implantation to have a medical team that has experience in the application of this type of therapy.

  19. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J

    2012-01-01

    Beta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress. We...... investigated the association between beta-blocker therapy, including type and dosage, and symptoms of anxiety and depression in a consecutive cohort of patients receiving an ICD....

  20. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    OpenAIRE

    Hoogwegt, Madelein; Kupper, Nina; Theuns, Dominic; Jordaens, Luc; Pedersen, Susanne

    2012-01-01

    textabstractBeta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress. We investigated the association between beta-blocker therapy, including type and dosage, and symptoms of anxiety and depression in a consecutive cohort of patients receiving an ICD. Between 2003 a...

  1. Incidence and causes of inappropriate detection and therapy by implantable defibrillators of cardioversion in patients with ventricular tachyarrhythmia

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Background Implantable cardioverter defibrillator (ICD) is the only effective therapy in patients with life threatening ventricular arrhythmias. Inappropriate detection and therapy by ICDs are the most common causes of side effects that affect the quality of life in ICD recipients. This study evaluated the incidence and causes of inappropriate detection and therapy by ICDs in patients in our hospital.Methods From January 2000 to December 2005, fifty patients who received ICD implantation for ventricular arrhythmias for prevention of sudden cardiac death were evaluated in this study. Each ICD was programmed using clinical arrhythmic and cardiac data of the patient before discharge. Patients were followed up by standard schedule after implantation and all data retrieved from each device were collected and saved for further analysis. Results No arrhythmic event was detected in 12/50 (24%) patients during the period of follow-up. Among the remaining patients, 11 (22%) experienced inappropriate detections and therapies during follow-up in this study. ICD detected 383 ventricular tachyarrhythmia (VT) and 108 ventricular fibrillation (VF) episodes and delivered 678 therapies. In VT group, ICD delivered 413 antitachycardiac pacings (ATPs) and 118 shocks, among which 78 ATPs and 9 shocks were initiated by 55/383 (14.3%) inappropriate detections. In VF group ICD delivered 147 shocks, among which 56 shocks were initiated by 28/108 (26.9%) inappropriate detections. Overall, more than 50% of these episodes were caused by atrial fibrillation (AF) with rapid ventricular response, followed by electromagnetic or myopotential interference. In addition, most inappropriate therapies occurred within one year after ICD implantation.Conclusions About one fifth of patients experienced ICD inappropriate detection and therapy after implantation. The main cause was AF with rapid ventricular response, followed by electromagnetic or myopotential interference.

  2. Relation of statin therapy to psychological functioning in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Theuns, Dominic A M J; Kupper, Nina

    2013-01-01

    Statin therapy is an important secondary prevention measure in cardiovascular disease. However, the side effects associated with statin use could potentially affect patients' quality of life. Little is known about the influence of statin therapy on the well-being and health status of cardiac...... patients, in general, and patients with an implantable cardioverter defibrillator (ICD), in particular. We investigated the association between statin therapy and symptoms of anxiety and depression and patients' health status during the 12 months after implantation, reckoning with statin type and dosage....... Consecutively implanted ICD patients (n = 409; 78.2% men) completed the Hospital Anxiety and Depression Scale and the Medical Outcomes Study Short Form 36-item Health Survey at baseline and 3, 6, and 12 months after implantation. The data were analyzed using general linear mixed modeling repeated measures...

  3. Right ventricular stimulation threshold at ICD implant predicts device therapy in primary prevention patients with ischaemic heart disease.

    Science.gov (United States)

    Atary, Jael Z; Borleffs, C Jan Willem; van der Bom, Johanna G; Trines, Serge A I P; Bootsma, Marianne; Zeppenfeld, Katja; van Erven, Lieselot; Schalij, Martin J

    2010-11-01

    Myocardial excitability is known (amongst other reasons) to be related to the degree of ischaemia, contractile dysfunction and heart failure. It was hypothesized that the right ventricular (RV) stimulation threshold has prognostic value with respect to the occurrence of ventricular arrhythmias (VAs) and patient survival in recipients of an implantable cardioverter defibrillator (ICD). Ischaemic heart disease patients receiving an ICD at Leiden University Medical Center as primary prevention for sudden cardiac death were included in this study. Right ventricular thresholds were determined at ICD implant. Data were collected on VAs triggering ICD therapy and on all-cause mortality. A total of 689 consecutive patients were included (87% male, age 63 ± 11 years, left ventricular ejection fraction (LVEF) 29 ± 11%) and followed for a median of 28 months. Post-implant RV-threshold was 0.7 ± 0.5 volt (V) at 0.5 ms pulse duration. Best dichotomous separation was reached at a cut-off of 1 V. During follow-up, 167 (24%) patients received appropriate ICD therapy, 88 (13%) had appropriate shocks and 134 (19%) died. Cumulative appropriate shock incidence for patients with RV threshold ≥ 1 V (n = 166) was 16% at 1 year, 24% at 3 years and 34% at 5 years compared with 4, 11 and 17% for patients with an RV-threshold implant has a strong independent prognostic value for the occurrence of VAs triggering appropriate ICD therapy, appropriate shocks and mortality.

  4. A Comparison of the Quality of Life of Patients With an Entirely Subcutaneous Implantable Defibrillator System Versus a Transvenous System (from the EFFORTLESS S-ICD Quality of Life Substudy)

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Mastenbroek, Mirjam H; Carter, Nathan;

    2016-01-01

    The first clinical results from the Evaluation of Factors Impacting Clinical Outcome and Cost Effectiveness of the subcutaneous implantable cardioverter defibrillator (EFFORTLESS S-ICD) Registry on the entirely S-ICD system are promising, but the impact of the S-ICD system on patients' quality of...

  5. Beta-blocker therapy is not associated with symptoms of depression and anxiety in patients receiving an implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    M.T. Hoogwegt (Madelein); N. Kupper (Nina); D.A.M.J. Theuns (Dominic); L.J.L.M. Jordaens (Luc); S.S. Pedersen (Susanne)

    2012-01-01

    textabstractBeta-blockers are frequently prescribed to implantable cardioverter-defibrillator (ICD) patients. Beta-blocker therapy has been proposed to induce emotional distress such as depression and anxiety, but a paucity of studies has examined the relationship between beta-blockers and distress.

  6. Implantable cardioverter defibrillator therapy in young patients with cardiomyopathies and channelopathies: a single Italian centre experience.

    Science.gov (United States)

    Migliore, Federico; Silvano, Maria; Zorzi, Alessandro; Bertaglia, Emanuele; Siciliano, Mariachiara; Leoni, Loira; De Franceschi, Pietro; Iliceto, Sabino; Corrado, Domenico

    2016-07-01

    This study was designed to prospectively evaluate the risk-benefit ratio of implantable cardioverter defibrillator (ICD) therapy in young patients with cardiomyopathies and channelopathies. The study population included 96 consecutive patients [68 men, median age 27 (22-32) years] with cardiomyopathies, such as arrhythmogenic right ventricular cardiomyopathy (n = 35), dilated cardiomyopathy (n = 17), hypertrophic cardiomyopathy (n = 15), Brugada syndrome (n = 14), idiopathic ventricular fibrillation (n = 5), left ventricular noncompaction (n = 4), long-QT syndrome (n = 4) and short-QT syndrome (n = 2), who were 18-35 years old at the time of ICD implantation. During a mean follow-up of 72.6 ± 53.3 months, one patient with end-stage hypertrophic cardiomyopathy died because of acute heart failure, and 11 patients underwent orthotopic heart transplantation. Twenty patients (20.8%) had a total of 38 appropriate ICD interventions (4%/year), and 26 patients (27.1%) experienced a total of 49 adverse ICD-related events (5.4%/year), including 23 inappropriate ICD interventions occurring in nine patients (9.4%) and 26 device-related complications requiring surgical revision occurring in 20 patients (20.8%). Lead failure/fracture requiring lead extraction was the most common complication (n = 9). A threshold for ICD therapy less than 300 ms was associated with a borderline significant lower probability of inappropriate ICD interventions (hazard ratio = 0.2; 95% confidence interval 0.02-1.2; P = 0.07), whereas underweight status was an independent predictor of device-related complications (hazard ratio = 5.4; 95% confidence interval 1.5-19.4; P = 0.01). In young patients with cardiomyopathies and channelopathies, ICD therapy provided life-saving protection by effectively terminating life-threatening ventricular arrhythmias. However, because ICD-related adverse events are common, the risk/benefit ratio should be

  7. Programmed Ventricular Stimulation to Risk Stratify for Early Cardioverter-Defibrillator Implantation to Prevent Tachyarrhythmias following Acute Myocardial Infarction (PROTECT-ICD): Trial Protocol, Background and Significance.

    Science.gov (United States)

    Zaman, Sarah; Taylor, Andrew J; Stiles, Martin; Chow, Clara; Kovoor, Pramesh

    2016-11-01

    The 'Programmed Ventricular Stimulation to Risk Stratify for Early Cardioverter-Defibrillator Implantation to Prevent Tachyarrhythmias following Acute Myocardial Infarction' (PROTECT-ICD) trial is an Australian-led multicentre randomised controlled trial targeting prevention of sudden cardiac death in patients who have at least moderately reduced cardiac function following a myocardial infarct (MI). The primary objective of the trial is to assess whether electrophysiological study to guide prophylactic implantation of an implantable cardioverter-defibrillator (ICD) early following MI (first 40 days) will lead to a significant reduction in sudden cardiac death and non-fatal arrhythmia. The secondary objective is to assess the utility of cardiac MRI (CMR) in assessing early myocardial characteristics, and its predictive value for both inducible ventricular tachycardia (VT) at EPS and SCD/ non-fatal arrhythmia at follow-up.

  8. Impact of carvedilol and metoprolol on inappropriate implantable cardioverter-defibrillator therapy

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Abu-Zeitone, Abeer; Jons, Christian;

    2013-01-01

    The goal of this study was to evaluate the effects of carvedilol and metoprolol on the endpoint of inappropriate implantable cardioverter-defibrillator therapy in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy) study.......The goal of this study was to evaluate the effects of carvedilol and metoprolol on the endpoint of inappropriate implantable cardioverter-defibrillator therapy in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy) study....

  9. Implantable cardioverter defibrillator therapy in pediatric and congenital heart disease patients: a single tertiary center experience in Korea

    Directory of Open Access Journals (Sweden)

    Bo Kyung Jin

    2013-03-01

    Full Text Available Purpose: The use of implantable cardioverter defibrillators (ICDs to prevent sudden cardiac death is increasing in children and adolescents. This study investigated the use of ICDs in children with congenital heart disease. Methods: This retrospective study was conducted on the clinical characteristics and effectiveness of ICD implantation at the department of pediatrics of a single tertiary center between 2007 and 2011. Results: Fifteen patients underwent ICD implantation. Their mean age at the time of implantation was 14.5±5.4 years (range, 2 to 22 years. The follow-up duration was 28.9±20.4 months. The cause of ICD implantation was cardiac arrest in 7, sustained ventricular tachycardia in 6, and syncope in 2 patients. The underlying disorders were as follows: ionic channelopathy in 6 patients (long QT type 3 in 4, catecholaminergic polymorphic ventricular tachycardia [CPVT] in 1, and J wave syndrome in 1, cardiomyopathy in 5 patients, and postoperative congenital heart disease in 4 patients. ICD coils were implanted in the pericardial space in 2 children (ages 2 and 6 years. Five patients received appropriate ICD shock therapy, and 2 patients received inappropriate shocks due to supraventricular tachycardia.During follow-up, 2 patients required lead dysfunction-related revision. One patient with CPVT suffered from an ICD storm that was resolved using sympathetic denervation surgery. Conclusion: The overall ICD outcome was acceptable in most pediatric patients. Early diagnosis and timely ICD implantation are recommended for preventing sudden death in high-risk children and patients with congenital heart disease.

  10. Psychological wellbeing and posttraumatic stress associated with implantable cardioverter defibrillator therapy in young adults with genetic heart disease.

    Science.gov (United States)

    Ingles, Jodie; Sarina, Tanya; Kasparian, Nadine; Semsarian, Christopher

    2013-10-09

    Sudden cardiac death is a tragic complication of a number of genetic heart diseases. Implantable cardioverter defibrillator (ICD) therapy plays an important role in prevention of sudden death. The psychological consequences of ICD therapy in young people with genetic heart disease are poorly understood. This study sought to better understand psychological wellbeing and identify symptoms of posttraumatic stress in young people who had experienced an ICD shock. Eligible patients (ICD implanted over 12 months prior) with an inherited cardiomyopathy or primary arrhythmogenic disorder, enrolled in the Australian Genetic Heart Disease Registry were included. Ninety patients completed the Hospital Anxiety and Depression Scale (HADS). Those patients who had an ICD shock (n=31) also completed the Impact of Events Scale-Revised (IES-R). While the mean HADS-Anxiety and IES-R scores were within the normal range in the total group (n=90), a significant subgroup reported symptoms of anxiety (38%), depression (17%) and posttraumatic stress (31%) indicative of the potential need for referral to clinical care. Overall, greater psychological distress in ICD patients was associated with female gender, a history of syncope, other comorbid medical conditions, and reporting of other distressing events (i.e., ICD complications). In those with an ICD shock, higher posttraumatic stress scores were associated with female gender and longer time to first shock. Patients with genetic heart diseases can experience psychological difficulties, including anxiety, depression and posttraumatic stress, related to ICD implantation and subsequent shocks. This signals the importance of offering patients access to targeted interventions, including psychological care and support. © 2013.

  11. Impact of programming strategies aimed at reducing nonessential implantable cardioverter defibrillator therapies on mortality: a systematic review and meta-analysis.

    Science.gov (United States)

    Tan, Vern Hsen; Wilton, Stephen B; Kuriachan, Vikas; Sumner, Glen L; Exner, Derek V

    2014-02-01

    Patients who receive implantable cardioverter defibrillator therapies are at higher risk of death versus those who do not. Programmed settings to reduce nonessential implantable cardioverter defibrillator therapies (therapy reduction programming) have been developed but may have adverse effects. This systematic review and meta-analysis assessed the relationship between therapy reduction programming with the risks of death from any cause, implantable cardioverter defibrillator shocks, and syncope. MEDLINE, EMBASE, and clinicaltrials.gov databases were searched to identify relevant studies. Those that followed patients for ≥6 months and reported mortality were included. Six met the inclusion criteria; 4 randomized (Comparison of Empiric to Physician-Tailored Programming of ICDs [EMPIRIC], Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy [MADIT-RIT], Avoid Delivering Therapies for Non-sustained Arrhythmias in ICD Patients III [ADVANCE III], and Programming Implantable Cardioverter-Defibrillators in Patients with Primary Prevention Indication to Prolong Time to First Shock [PROVIDE]) and 2 prospective studies (Role of Long Detection Window Programming in Patients With Left Ventricular Dysfunction, Non-ischemic Etiology in Primary Prevention Treated with a Biventricular ICD [RELEVANT] and Primary Prevention Parameters Evaluation [PREPARE]). These 6 studies included 7687 (3598 conventional and 4089 therapy reduction programming) patients. Most (77%) participants were men, had a history of ischemic heart disease (56%), and were prescribed β-blockers (84%). Therapy reduction programming was associated with a 30% relative reduction in mortality (95% confidence interval, 16%-41%; Pprogramming (P=0.5). Therapy reduction programming results in a large, significant, and consistent reduction in mortality, with no apparent increase in the risk of syncope.

  12. The role of EP-guided therapy in ventricular arrhythmias: beta-blockers, sotalol, and ICD's.

    Science.gov (United States)

    Capucci, A; Aschieri, D; Villani, G Q

    2000-01-01

    Arrhythmic death can be reduced by antiarrhythmic drugs to a range of 24%. Electrophysiologic study by testing noninducibility of ventricular arrhythmia represents the classic method for evaluating the effectiveness of drug therapy. Several clinical studies have shown thaat sotalol suppresses VT induction and prevents arrhythmias recurrences at long term follow-up in 23% to 67% of patients. The efficacy of sotalol EP guided therapy in preventing VT/VF is not necessarily related to prevention of sudden death. In the ESVEM study the superiority of d,l-sotalol to other antiarrhythmic drugs was confirmed. The response to programmed ventricular stimulation was found to be strongly predictive for arrhythmia free state while the failure of sotalol therapy to suppress VT at the EP study was associated with an high recurrence rate (40%). However, EP study failes to predict freedom from sudden death. The beta-blocking activity of racemic sotalol may account for some of the observed survival benefit.Beta-blockers therapy reduces mortality in patients after myocardial infarction primarily by a reduction of sudden death. A reduction of death, worsening heart failure and life threatening ventricular arrhythmias was shown in a recent study on carvedilol. In the prospective study of Steinbeck the EP guided-therapy did not improve the overall outcome when compared to metoprolol. Suppression of inducible arrhythmias by antiarrhythmic drugs was associated with a better outcome. The effectiveness of defibrillator therapy in reducing overall mortality, has been uncertain since great clinical trials have been concluded. MADIT, AVID and CASH trials confirmed the superiority of ICD therapy over antiarrhythmic drugs therapy: ICD should be considered the first choice therapy in post-cardiac arrest patients. The ongoing BEST Trial will give us further responses about the interaction between EP study and metoprolol effect compared to ICD in patients post myocardial infarction also focusing on

  13. Successful intermuscular implantation of subcutaneous implantable cardioverter defibrillator in a Japanese patient with pectus excavatum.

    Science.gov (United States)

    Kondo, Yusuke; Ueda, Marehiko; Winter, Joachim; Nakano, Miyo; Nakano, Masahiro; Ishimura, Masayuki; Miyazawa, Kazuo; Tateno, Kaoru; Kobayashi, Yoshio

    2017-02-01

    The entirely subcutaneous implantable cardioverter-defibrillator (ICD) system was developed to provide a life-saving defibrillation therapy that does not affect the heart and vasculature. The subcutaneous ICD is preferred over the transvenous ICD for patients with a history of recurrent infection presenting major life-threatening rhythms. In this case report, we describe the first successful intermuscular implantation of a completely subcutaneous ICD in a Japanese patient with pectus excavatum. There were no associated complications with the device implantation or lead positioning. Further, the defibrillation threshold testing did not pose any problem with the abnormal anatomy of the patient.

  14. The dilemma of ICD implant testing.

    Science.gov (United States)

    Swerdlow, Charles D; Russo, Andrea M; Degroot, Paul J

    2007-05-01

    Ventricular fibrillation (VF) has been induced at implantable cardioverter defibrillator (ICD) implant to ensure reliable sensing, detection, and defibrillation. Despite its risks, the value was self-evident for early ICDs: failure of defibrillation was common, recipients had a high risk of ventricular tachycardia (VT) or VF, and the only therapy for rapid VT or VF was a shock. Today, failure of defibrillation is rare, the risk of VT/VF is lower in some recipients, antitachycardia pacing is applied for fast VT, and vulnerability testing permits assessment of defibrillation efficacy without inducing VF in most patients. This review reappraises ICD implant testing. At implant, defibrillation success is influenced by both predictable and unpredictable factors, including those related to the patient, ICD system, drugs, and complications. For left pectoral implants of high-output ICDs, the probability of passing a 10 J safety margin is approximately 95%, the probability that a maximum output shock will defibrillate is approximately 99%, and the incidence of system revision based on testing is < or = 5%. Bayes' Theorem predicts that implant testing identifies < or = 50% of patients at high risk for unsuccessful defibrillation. Most patients who fail implant criteria have false negative tests and may undergo unnecessary revision of their ICD systems. The first-shock success rate for spontaneous VT/VF ranges from 83% to 93%, lower than that for induced VF. Thus, shocks for spontaneous VT/VF fail for reasons that are not evaluated at implant. Whether system revision based on implant testing improves this success rate is unknown. The risks of implant testing include those related to VF and those related to shocks alone. The former may be due to circulatory arrest alone or the combination of circulatory arrest and shocks. Vulnerability testing reduces risks related to VF, but not those related to shocks. Mortality from implant testing probably is 0.1-0.2%. Overall, VF should

  15. The effect of ICD programming on inappropriate and appropriate ICD Therapies in ischemic and nonischemic cardiomyopathy: the MADIT-RIT trial.

    Science.gov (United States)

    Sedláček, Kamil; Ruwald, Anne-Christine; Kutyifa, Valentina; McNitt, Scott; Thomsen, Poul Erik Bloch; Klein, Helmut; Stockburger, Martin; Wichterle, Dan; Merkely, Bela; DE LA Concha, Joaquin Fernandez; Swissa, Moshe; Zareba, Wojciech; Moss, Arthur J; Kautzner, Josef; Ruwald, Martin H

    2015-04-01

    The MADIT-RIT trial demonstrated reduction of inappropriate and appropriate ICD therapies and mortality by high-rate cut-off and 60-second-delayed VT therapy ICD programming in patients with a primary prophylactic ICD indication. The aim of this analysis was to study effects of MADIT-RIT ICD programming in patients with ischemic and nonischemic cardiomyopathy. First and total occurrences of both inappropriate and appropriate ICD therapies were analyzed by multivariate Cox models in 791 (53%) patients with ischemic and 707 (47%) patients with nonischemic cardiomyopathy. Patients with ischemic and nonischemic cardiomyopathy had similar incidence of first inappropriate (9% and 11%, P = 0.21) and first appropriate ICD therapy (11.6% and 14.1%, P = 0.15). Patients with ischemic cardiomyopathy had higher mortality rate (6.1% vs. 3.3%, P = 0.01). MADIT-RIT high-rate cut-off (arm B) and delayed VT therapy ICD programming (arm C) compared with conventional (arm A) ICD programming were associated with a significant risk reduction of first inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy (HR range 0.11-0.34, P programming and delayed VT therapy ICD programming in both ischemic and nonischemic cardiomyopathy patients. High-rate cut-off and delayed VT therapy ICD programming are associated with significant reduction in first and total inappropriate and appropriate ICD therapy in patients with ischemic and nonischemic cardiomyopathy. © 2014 Wiley Periodicals, Inc.

  16. First inappropriate implantable cardioverter defibrillator therapy is often due to inaccurate device programming: analysis of the French OPERA registry.

    Science.gov (United States)

    Leenhardt, Antoine; Defaye, Pascal; Mouton, Elisabeth; Delay, Marc; Delarche, Nicolas; Dupuis, Jean-Marc; Bizeau, Olivier; Mabo, Philippe; Cheggour, Saida; Babuty, Dominique

    2012-10-01

    Inappropriate therapy delivered by implantable cardioverter defibrillators (ICDs) remains a challenge. The OPERA registry measured the times to, and studied the determinants of, first appropriate (FAT) and inappropriate (FIT) therapies delivered by single-, dual- and triple-chamber [cardiac resynchronization therapy defibrillator (CRT-D)] ICD. We entered 636 patients (mean age = 62.0 ± 13.5 years; 88% men) in the registry, of whom 251 received single-, 238 dual-, and 147 triple-chamber ICD, for primary (30.5%) or secondary (69.5%) indications. We measured times to FAT and FIT as a function of multiple clinical characteristics, examined the effects of various algorithm components on the likelihood of FAT and FIT delivery, and searched for predictors of FAT and FIT. Over 22.8 ± 8.8 months of observation, 184 patients (28.9%) received FAT and 70 (11.0%) received FIT. Ventricular tachycardia (VT) was the trigger of 88% of FAT, and supraventricular tachycardia was the trigger of 91% of FIT. The median times to FIT (90 days; range 49-258) and FAT (171 days; 50-363) were similar. The rate of FAT was higher (P <0.001) in patients treated for secondary than primary indications, while that of FIT were similar in both groups. Out of 57 analysable FIT, 27 (47.4%) could have been prevented by fine tuning the device programming like the sustained rate duration or the VT discrimination algorithm. First inappropriate therapy occurred in 11% of 636 ICD recipients followed for ∼2 years. Nearly 50% of FIT could have been prevented by improving device programming.

  17. Management of radiation therapy patients with cardiac defibrillator or pacemaker.

    Science.gov (United States)

    Salerno, Francesca; Gomellini, Sara; Caruso, Cristina; Barbara, Raffaele; Musio, Daniela; Coppi, Tamara; Cardinale, Mario; Tombolini, Vincenzo; de Paula, Ugo

    2016-06-01

    The increasing growth of population with cardiac implantable electronic devices (CIEDs) such as Pacemaker (PM) and Implantable Cardiac Defibrillators (ICD), requires particular attention in management of patients needing radiation treatment. This paper updates and summarizes some recommendations from different international guidelines. Ionizing radiation and/or electromagnetic interferences could cause device failure. Current approaches to treatment in patients who have these devices vary among radiation oncology centres. We refer to the German Society of Radiation Oncology and Cardiology guidelines (ed. 2015); to the Society of Cardiology Australia and New Zealand Statement (ed. 2015); to the guidelines in force in the Netherlands (ed. 2012) and to the Italian Association of Radiation Oncology recommendations (ed. 2013) as reported in the guidelines for the treatment of breast cancer in patients with CIED. Although there is not a clear cut-off point, risk of device failure increases with increasing doses. Cumulative dose and pacing dependency have been combined to categorize patients into low-, medium- and high-risk groups. Measures to secure patient safety are described for each category. The use of energy ≤6MV is preferable and it's strongly recommended not to exceed a total dose of 2 Gy to the PM and 1 Gy for ICD. Given the dangers of device malfunction, radiation oncology departments should adopt all the measures designed to minimize the risk to patients. For this reason, a close collaboration between cardiologist, radiotherapist and physicist is necessary.

  18. A prospective study of anxiety in ICD patients with a pilot randomized controlled trial of cognitive behavioral therapy for patients with moderate to severe anxiety

    DEFF Research Database (Denmark)

    Qintar, Mohammed; George, Jason J; Panko, Melanie

    2015-01-01

    consisted of two parts: part 1 (N = 690) was a prospective cross-sectional observational study of consecutive ICD patients. Patients completed the Beck Anxiety Inventory (BAI), Generalized Anxiety Disorder Scale (GAD-7), Florida Shock Anxiety Scale (FSAS), and Florida Patient Acceptance Survey (FPAS......PURPOSE: Stress and anxiety are potential consequences from arrhythmias and implantable cardioverter defibrillator (ICD) shocks that can contribute to substantial morbidity. We assessed anxiety associated with an ICD and whether cognitive behavioral therapy (CBT) reduces anxiety. METHODS: The study......) psychometric tests. Part 2 (N = 29) was a pilot randomized controlled trial of CBT (three sessions in 3 months) vs. usual care (UC) in patients with BAI ≥ 19 from part 1. RESULTS: The median BAI and GAD-7 scores were 5 and 2, respectively. By BAI scores, 64.5 % had minimal and 3.9 % had severe anxiety. By GAD...

  19. Sex-Based Differences in Cardiac Arrhythmias, ICD Utilisation and Cardiac Resynchronisation Therapy.

    Science.gov (United States)

    Ghani, A; Maas, A H E M; Delnoy, P P H M; Ramdat Misier, A R; Ottervanger, J P; Elvan, A

    2011-01-01

    Many important differences in the presentation and clinical course of cardiac arrhythmias are present between men and women that should be accounted for in clinical practice. In this paper, we review published data on gender differences in cardiac excitable properties, supraventricular tachycardias, ventricular tachycardias, sudden cardiac death, and the utilisation of implantable defibrillators and cardiac resynchronisation therapy. Women have a higher heart rate at rest, and a longer QT interval than men. They further have a narrower QRS complex and lower QRS voltages on the 12-lead ECG with more often non-specific repolarisation abnormalities at rest. Supraventricular tachycardias, such as AV nodal reentrant tachycardia, are twice as frequent in women compared with men. Atrial fibrillation, however, has a 1.5-fold higher prevalence in men. The triggers for idiopathic right ventricular outflow tract tachycardia (VT) initiation are gender specific, i.e. hormonal changes play an important role in the occurrence of these VTs in women. There are clear-cut gender differences in acquired and congenital LQTS. Brugada syndrome affects men more commonly and severely than women. Sudden cardiac death is less prevalent in women at all ages and occurs 10 years later in women than in men. This may be related to the later onset of clinically manifest coronary heart disease in women. Among patients who receive ICDs and CRT devices, women appear to be under-represented, while they may benefit even more from these novel therapies.

  20. Temporal Influence of Heart Failure Hospitalizations Prior to Implantable Cardioverter Defibrillator or Cardiac Resynchronization Therapy With Defibrillator on Subsequent Outcome in Mild Heart Failure Patients (from MADIT-CRT)

    DEFF Research Database (Denmark)

    Lee, Andy Y; Moss, Arthur J; Ruwald, Martin H;

    2015-01-01

    The temporal effect of heart failure (HF) hospitalization occurring at different time periods before implantation has not yet been studied in detail. The aim of the present study was to investigate the potential association between time from last HF hospitalization to device implantation and effe......The temporal effect of heart failure (HF) hospitalization occurring at different time periods before implantation has not yet been studied in detail. The aim of the present study was to investigate the potential association between time from last HF hospitalization to device implantation...... and effects on subsequent outcomes and benefit from cardiac resynchronization therapy with a defibrillator (CRT-D). Multivariate Cox models were used to determine the temporal influence of previous HF hospitalization on the end point of HF or death within all left bundle branch block implantable cardioverter......-defibrillator (ICD) and CRT-D patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) trial (n = 1,250) and to evaluate the clinical benefit of CRT-D implantation, comparing CRT-D patients with ICD patients within each previous HF hospitalization...

  1. Statin therapy reduces inappropriate shock in non-ischemic patients with mild heart failure

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine H.; Zareba, Wojciech; Jons, Christian

    2013-01-01

    BACKGROUND: The relationship between diabetes mellitus and risk of inappropriate or appropriate therapy in patients receiving an implantable cardioverter-defibrillator (ICD) and resynchronization therapy has not been investigated thoroughly. The effect of innovative ICD programming on therapy...... delivery in these patients is unknown. METHODS AND RESULTS: The Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) randomized patients with a primary prophylactic ICD indication to 3 different types of ICD programming: conventional programming with a ventricular...

  2. Relevance of guideline-based ICD indications to clinical practice.

    Science.gov (United States)

    Al-Jefairi, Nora; Burri, Haran

    2014-01-01

    The implantable cardioverter-defibrillator (ICD) has established itself as life-saving therapy in patients at risk for sudden cardiac death. Remarkable technological advances have made ICDs easier and safer to implant, with improved therapeutic and diagnostic functions and reduced morbidity. Guidelines on ICD indications have been proposed by American and European scientific societies since a number of years, based upon trials and expert opinion. In the context of variable economic and political constraints, it is questionable whether these guidelines may be applied to all settings. This review discusses the guideline-based indications, critically examines their applicability to clinical practice, and discusses alternatives to ICD therapy.

  3. Cardiovascular Magnetic Resonance to Predict Appropriate Implantable Cardioverter Defibrillator Therapy in Ischemic and Nonischemic Cardiomyopathy Patients Using Late Gadolinium Enhancement Border Zone: Comparison of Four Analysis Methods.

    Science.gov (United States)

    Jablonowski, Robert; Chaudhry, Uzma; van der Pals, Jesper; Engblom, Henrik; Arheden, Håkan; Heiberg, Einar; Wu, Katherine C; Borgquist, Rasmus; Carlsson, Marcus

    2017-09-01

    Late gadolinium enhancement (LGE) border zone on cardiac magnetic resonance imaging has been proposed as an independent predictor of ventricular arrhythmias. The purpose was to determine whether size and heterogeneity of LGE predict appropriate implantable cardioverter defibrillator (ICD) therapy in ischemic cardiomyopathy (ICM) and nonischemic cardiomyopathy (NICM) patients and to evaluate 4 LGE border-zone algorithms. ICM and NICM patients who underwent LGE cardiac magnetic resonance imaging prior to ICD implantation were retrospectively included. Two semiautomatic algorithms, expectation maximization, weighted intensity, a priori information and a weighted border zone algorithm, were compared with a modified full-width half-maximum and a 2-3SD threshold-based algorithm (2-3SD). Hazard ratios were calculated per 1% increase in LGE. A total of 74 ICM and 34 NICM were followed for 63 months (1-140) and 52 months (0-133), respectively. ICM patients had 27 appropriate ICD events, and NICM patients had 7 ICD events. In ICM patients with primary prophylactic ICD, LGE border zone predicted ICD therapy in univariable and multivariable analysis measured by the expectation maximization, weighted intensity, a priori information, weighted border zone, and modified full-width half-maximum algorithms (hazard ratios 1.23, 1.22, and 1.05, respectively; P<0.05; negative predictive value 92%). For NICM, total LGE by all 4 methods was the strongest predictor (hazard ratios, 1.03-1.04; P<0.05), though the number of events was small. Appropriate ICD therapy can be predicted in ICM patients with primary prevention ICD by quantifying the LGE border zone. In NICM patients, total LGE but not LGE border zone had predictive value for ICD therapy. However, the algorithms used affects the predictive value of these measures. © 2017 American Heart Association, Inc.

  4. Rationale and design of the PRAETORIAN trial: A Prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter- defibrillator therapy

    NARCIS (Netherlands)

    L.R.A. Olde Nordkamp (Louise R.A.); R.E. Knops (Reinoud); G.H. Bardy (Gust); Y. Blaauw (Yuri); L. Boersma (Lucas); J.S. Bos (Johannes); P.P.H.M. Delnoy (Peter Paul); P.F.H.M. van Pascal; A.H.G. Driessen (Antoine); J.R. de Groot (Joris); J.P.R. Herrman; L.J.L.M. Jordaens (Luc); K.M. Kooiman (Kirsten); A.H. Maass (Alexander); M. Meine (Mathias); Y. Mizusawa (Yuka); S.G. Molhoek (Sander); J. van Opstal (Jurjen); J.G.P. Tijssen (Jan); A.A.M. Wilde (Arthur)

    2012-01-01

    textabstractBackground: Implantable cardioverter-defibrillators (ICDs) are widely used to prevent fatal outcomes associated with life-threatening arrhythmic episodes in a variety of cardiac diseases. These ICDs rely on transvenous leads for cardiac sensing and defibrillation. A new entirely subcutan

  5. Magnets and implantable cardioverter defibrillators: What′s the problem?

    Directory of Open Access Journals (Sweden)

    Yiliam F Rodriguez-Blanco

    2013-01-01

    Full Text Available A growing number of surgical patients present to the operating room with implantable cardioverter defibrillators (ICD. Peri-operative care of these patients dictates that ICD function be suspended for many surgical procedures to avoid inappropriate, and possibly harmful, ICD therapy triggered by electromagnetic interference (EMI. An alternative to reprogramming the ICD is the use of a magnet to temporarily suspend its function. However, this approach is not without complications. We report a case where magnet use failed to inhibit ICD sensing of EMI, and a shock was delivered to the patient. Measures to decrease EMI, controversies regarding magnet use, and expert recommendations are discussed.

  6. Magnets and implantable cardioverter defibrillators: what's the problem?

    Science.gov (United States)

    Rodriguez-Blanco, Yiliam F; Souki, Fouad; Tamayo, Evelyn; Candiotti, Keith

    2013-01-01

    A growing number of surgical patients present to the operating room with implantable cardioverter defibrillators (ICD). Peri-operative care of these patients dictates that ICD function be suspended for many surgical procedures to avoid inappropriate, and possibly harmful, ICD therapy triggered by electromagnetic interference (EMI). An alternative to reprogramming the ICD is the use of a magnet to temporarily suspend its function. However, this approach is not without complications. We report a case where magnet use failed to inhibit ICD sensing of EMI, and a shock was delivered to the patient. Measures to decrease EMI, controversies regarding magnet use, and expert recommendations are discussed.

  7. The mismatch between patient life expectancy and the service life of implantable devices in current cardioverter-defibrillator therapy: a call for larger device batteries.

    Science.gov (United States)

    Neuzner, Jörg

    2015-06-01

    In 2005, Bob Hauser published a paper in the Journal of the American College of Cardiology entitled "The growing mismatch between patient longevity and the service life of Implantable Cardioverter-Defibrillators". Now, nearly a decade later, I would like to perform a second look on the problem of a mismatching between ICD device service life and the survival of ICD recipients. Since 2005, the demographics of the ICD population has changed significantly. Primary prevention has become the dominant indication in defibrillator therapy and device implantation is indicated more and more in earlier stages of cardiac diseases. In former larger scale ICD trials, the patient average 5-year survival probability was in a range of 68-71%; in newer CRT-D trials in a range of 72-88%. Due to a progressively widened ICD indication and implantation preferentially performed in patients with better life expectancy, the problem of inadequate device service life is of growing importance. The early days of defibrillator therapy started with a generator volume of 145 ccm and a device service life life were similar challenges for the technicians. Today, we have reached a formerly unexpected extent of device miniaturization. However, technologic improvements were often preferentially translated in further device miniaturization and not in prolonging device service life. In his analysis, Bob Hauser reported a prolonged device service life of 2.3 years in ICD models with a larger battery capacity of 0.54 up to 0.69 Ah. Between 2008 and 2014, several studies had been published on the problem of ICD longevity in clinical scenarios. These analyses included "older" and currently used single chamber, dual chamber and CRT devices. The reported average 5-year device service life ranged from 0 to 75%. Assuming today technology, larger battery capacities will only result in minimal increase in device volume. Selected ICD patients may further benefit from device miniaturization-but the vast majority

  8. State of the art of ICD programming

    DEFF Research Database (Denmark)

    Mastenbroek, M H; Pedersen, Susanne S.; Versteeg, H

    2014-01-01

    The lifesaving benefits of implantable cardioverter defibrillator (ICD) therapy are more and more weighted against possible harm (e.g. unnecessary device therapy, procedural complications, device malfunction etc.) which might have adverse effects on patients' perceived health status and quality...... of life. Hence, there has been an increasing interest in the optimisation of ICD programming to prevent inappropriate and appropriate but unnecessary device therapy. The purpose of the current report is to give an overview of research into the optimisation of ICD programming and present the design......, were eligible to participate. In all patients a prolonged detection of 60/80 intervals was programmed. The primary objective of the study is to investigate whether enhanced programming to further reduce ICD therapies is safe. The secondary objective is to examine the impact of enhanced programming...

  9. Implantable cardioverter-defibrillator oversensing due to electric shock

    Directory of Open Access Journals (Sweden)

    Jurčević Ružica

    2010-01-01

    Full Text Available Introduction. We described the first case of oversensing due to electric shock in Serbia, in a 54-year-old man who had implantable cardioverter-defibrillator (ICD. Case Outline. In July 2002, the patient had acute anteroseptal myocardial infarction and ventricular fibrillation (VF which was terminated with six defibrillation shocks of 360 J. Coronary angiography revealed 30% stenosis of circumflex artery, the left anterior descending coronary artery was recanalized and the right coronary artery was without stenosis. Left ventricular ejection fraction was 20%. In December 2003, an electrophysiology study was performed and ventricular tachycardia (VT was induced and terminated with 200 J defibrillation shock. Single chamber ICD Medtronic Gem III VR was implanted in January 2004 and defibrillation threshold was 12 J. The patient was followed up during three years every three months and there were no VT/VF episodes and VT/VF therapies. In December 2007, the patient experienced electric shock through the fork while he was making barbecue on the electric grill. ICD recognized this event in VF zone (oversensing and delivered defibrillation shock of 18 J. The electrogram of the episode showed ventricular sensing - intrinsic sinus rhythm with electric shock potentials which were misidentified as VF. After charge time of 3.16 seconds, ICD delivered defibrillation shock and sinus rhythm was still present. Conclusion. Oversensing of ICD has different aetiology and the most common cause is supraventricular tachyarrhythmia.

  10. Part 6: electrical therapies: automated external defibrillators, defibrillation, cardioversion, and pacing: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care.

    Science.gov (United States)

    Link, Mark S; Atkins, Dianne L; Passman, Rod S; Halperin, Henry R; Samson, Ricardo A; White, Roger D; Cudnik, Michael T; Berg, Marc D; Kudenchuk, Peter J; Kerber, Richard E

    2010-11-02

    The recommendations for electrical therapies described in this section are designed to improve survival from SCA and life-threatening arrhythmias. Whenever defibrillation is attempted, rescuers must coordinate high-quality CPR with defibrillation to minimize interruptions in chest compressions and to ensure immediate resumption of chest compressions after shock delivery. The high first-shock efficacy of newer biphasic defibrillators led to the recommendation of single shocks plus immediate CPR instead of 3-shock sequences that were recommended prior to 2005 to treat VF. Further data are needed to refine recommendations for energy levels for defibrillation and cardioversion using biphasic waveforms.

  11. Rationale and design of the PRAETORIAN trial : A Prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter-defibrillator therapy

    NARCIS (Netherlands)

    Nordkamp, Louise R. A. Olde; Knops, Reinoud E.; Bardy, Gust H.; Blaauw, Yuri; Boersma, Lucas V. A.; Bos, Johannes S.; Delnoy, Peter Paul H. M.; van Dessel, Pascal F. H. M.; Driessen, Antoine H. G.; de Groot, Joris R.; Herrman, Jean Paul R.; Jordaens, Luc J. L. M.; Kooiman, Kirsten M.; Maass, Alexander H.; Meine, Mathias; Mizusawa, Yuka; Molhoek, Sander G.; van Opstal, Jurjen; Tijssen, Jan G. P.; Wilde, Arthur A. M.

    2012-01-01

    Background Implantable cardioverter-defibrillators (ICDs) are widely used to prevent fatal outcomes associated with life-threatening arrhythmic episodes in a variety of cardiac diseases. These ICDs rely on transvenous leads for cardiac sensing and defibrillation. A new entirely subcutaneous ICD over

  12. Behandling med implanterbar defibrillator

    DEFF Research Database (Denmark)

    Roseva-Nielsen, Natasha G; Svendsen, Jesper Hastrup

    2003-01-01

    About 20 years ago the first patient received an implantable cardioverter defibrillator (ICD), and since then the number of implants have increased dramatically. The ICD can terminate ventricular fibrillation and ventricular tachycardia. Studies of secondary prophylaxis show that ICD treatment can...

  13. Identifying patients with less potential to benefit from implantable cardioverter-defibrillator therapy: comparison of the performance of four risk scoring systems.

    Science.gov (United States)

    Kaura, Amit; Sunderland, Nicholas; Kamdar, Ravi; Petzer, Edward; McDonagh, Theresa; Murgatroyd, Francis; Dhillon, Para; Scott, Paul

    2017-08-01

    Patients at high non-sudden cardiac death risk may gain no significant benefit from implantable cardioverter-defibrillator (ICD) therapy. A number of approaches have been proposed to identify these patients, including single clinical markers and more complex scoring systems. The aims of this study were to use the proposed scoring systems to (1) establish how many current ICD recipients may be too high risk to derive significant benefit from ICD therapy and (2) evaluate how well the scoring systems predict short-term mortality in an unselected ICD cohort. We performed a single-centre retrospective observational study of all new ICD implants over 5 years (2009-2013). We used four published scoring systems (Bilchick, Goldenberg, Kramer and Parkash) and serum urea to identify new ICD recipients whose short-term predicted mortality risk was high. We evaluated how well the scoring systems predicted death. Over 5 years, there were 406 new implants (79% male, mean age 70 (60-76), 58% primary prevention). During a follow-up of 936 ± 560 days, 96 patients died. Using the scoring systems, the proportion of ICD recipients predicted to be at high short-term mortality risk were 5.9% (Bilchick), 34.7% (Goldenberg), 7.4% (Kramer), 21.4% (Parkash) and 25% (urea, cut-off of >9.28 mM). All four risk scores predicted mortality (P systems, a significant proportion of current ICD recipients are at high short-term mortality risk. Although all four scoring systems predicted mortality during follow-up, none significantly outperformed serum urea.

  14. Effect of supplemented intake of omega-3 fatty acids on arrhythmias in patients with ICD: fish oil therapy may reduce ventricular arrhythmia.

    Science.gov (United States)

    Weisman, Dalit; Beinart, Roy; Erez, Aharon; Koren-Morag, Nira; Goldenberg, Ilan; Eldar, Michael; Glikson, Michael; Luria, David

    2017-09-01

    The aim of this study was to evaluate the effects of fish oils, including eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA), on ventricular tachyarrhythmic episodes (VTEs) in implantable cardioverter defibrillator (ICD) recipients with ischemic cardiomyopathy. One hundred five ICD recipients with ischemic cardiomyopathy received 3.6 g of EPA and DHA and placebo for 6 months, each at a random order, with a 4-month washout period between treatments. Eighty-seven patients completed the 16-month study protocol. The primary end point was any VTE (including sustained and non-sustained ventricular tachycardias at a rate of >150 bpm) as recorded by the ICDs. Secondary end points included device therapy (anti-tachycardia pacing (ATP) or shocks). During treatment with fish oils, there was a significant increase in EPA and DHA concentrations in red blood cells (RBCs) and subcutaneous fat tissue. Among 87 patients who completed the study protocol, the mean number of VTEs was significantly lower during treatment with fish oil (1.7) vs. placebo (5.6; p = 0.035). Appropriate device therapy for VTE occurred in 18 (21%) patients. Fish oil therapy was associated with a trend toward fewer VTEs terminated with ATP (2.8 ± 13.7 vs. 0.5 ± 2.1, respectively; p = 0.077). VTE terminated by ICD shocks, however, was rare, and rates were similar between both groups (0.11 ± 0.6 vs. 0.10 ± 0.4, p = not significant, respectively). Our data suggest that fish oil therapy may be associated with a reduction in the frequency of VTE in ICD recipients with ischemic cardiomyopathy.

  15. Implantable defibrillators improve survival in patients with mildly symptomatic heart failure receiving cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Gold, Michael R; Daubert, Jean-Claude; Abraham, William T;

    2013-01-01

    Cardiac resynchronization therapy (CRT) decreases mortality, improves functional status, and induces reverse left ventricular remodeling in selected populations with heart failure. These benefits have been noted with both CRT-pacemakers as well as those devices with defibrillator backup (CRT...

  16. Reduction of the inappropriate ICD therapies by implementing a new fuzzy logic-based diagnostic algorithm.

    Science.gov (United States)

    Lewandowski, Michał; Przybylski, Andrzej; Kuźmicz, Wiesław; Szwed, Hanna

    2013-09-01

    The aim of the study was to analyze the value of a completely new fuzzy logic-based detection algorithm (FA) in comparison with arrhythmia classification algorithms used in existing ICDs in order to demonstrate whether the rate of inappropriate therapies can be reduced. On the basis of the RR intervals database containing arrhythmia events and controls recordings from the ICD memory a diagnostic algorithm was developed and tested by a computer program. This algorithm uses the same input signals as existing ICDs: RR interval as the primary input variable and two variables derived from it, onset and stability. However, it uses 15 fuzzy rules instead of fixed thresholds used in existing devices. The algorithm considers 6 diagnostic categories: (1) VF (ventricular fibrillation), (2) VT (ventricular tachycardia), (3) ST (sinus tachycardia), (4) DAI (artifacts and heart rhythm irregularities including extrasystoles and T-wave oversensing-TWOS), (5) ATF (atrial and supraventricular tachycardia or fibrillation), and 96) NT (sinus rhythm). This algorithm was tested on 172 RR recordings from different ICDs in the follow-up of 135 patients. All diagnostic categories of the algorithm were present in the analyzed recordings: VF (n = 35), VT (n = 48), ST (n = 14), DAI (n = 32), ATF (n = 18), NT (n = 25). Thirty-eight patients (31.4%) in the studied group received inappropriate ICD therapies. In all these cases the final diagnosis of the algorithm was correct (19 cases of artifacts, 11 of atrial fibrillation and 8 of ST) and fuzzy rules algorithm implementation would have withheld unnecessary therapies. Incidence of inappropriate therapies: 3 vs. 38 (the proposed algorithm vs. ICD diagnosis, respectively) differed significantly (p fuzzy logic based algorithm seems to be promising and its implementation could diminish ICDs inappropriate therapies. We found FA usefulness in correct diagnosis of sinus tachycardia, atrial fibrillation and artifacts in comparison with tested ICDs.

  17. Cardiac Resynchronization Therapy Reduces Ventricular Arrhythmias in Primary but Not Secondary Prophylactic Implantable Cardioverter Defibrillator Patients: Insight From the Resynchronization in Ambulatory Heart Failure Trial.

    Science.gov (United States)

    Sapp, John L; Parkash, Ratika; Wells, George A; Yetisir, Elizabeth; Gardner, Martin J; Healey, Jeffrey S; Thibault, Bernard; Sterns, Laurence D; Birnie, David; Nery, Pablo B; Sivakumaran, Soori; Essebag, Vidal; Dorian, Paul; Tang, Anthony S L

    2017-03-01

    The RAFT (Resynchronization in Ambulatory Heart Failure Trial) demonstrated that cardiac resynchronization therapy (CRT) reduced both mortality and heart failure hospitalizations in patients with functional class II or III heart failure and widened QRS. We examined the influence of CRT on ventricular arrhythmias in patients with primary versus secondary prophylaxis defibrillator indications. All ventricular arrhythmias among RAFT study participants were downloaded and adjudicated by 2 blinded reviewers with an overreader for disagreements and committee review for remaining discrepancies. Incidence of ventricular arrhythmias among patients randomized to CRT-D versus implantable cardioverter defibrillator (ICD) were compared within the groups of patients treated for primary prophylaxis and for secondary prophylaxis. Of 1798 enrolled patients, 1764 had data available for adjudication and were included. Of these, 1531 patients were implanted for primary prophylaxis, while 233 patients were implanted for secondary prophylaxis; 884 patients were randomized to ICD and 880 to CRT-D. During 5953.6 patient-years of follow-up, there were 11 278 appropriate ICD detections of ventricular arrhythmias. In the primary prophylaxis group, CRT-D significantly reduced incidence ventricular arrhythmias in comparison to ICD (hazard ratio, 0.86; 95% confidence interval, 0.74-0.99; P=0.044). This effect was not seen in the secondary prophylaxis group (hazard ratio, 1.14; 95% confidence interval, 0.82-1.58; P=0.45). CRT-D was not associated with significant differences in overall ventricular arrhythmia burden in either group. CRT reduced the rate of onset of new ventricular arrhythmias detected by ICDs in patients without a history of prior ventricular arrhythmias. This effect was not observed among patients who had prior ventricular arrhythmias. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00251251. © 2017 American Heart Association, Inc.

  18. Living with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Knudsen, Charlotte; Dilling, Karen;

    2017-01-01

    Hospital were asked to complete a purpose-designed and standardized set of questionnaires. The level of satisfaction with information provision was high; only 13.1% were dissatisfied. Psychological support for patients (39.9%), their relatives (43.1%), and deactivation of the ICD towards end of life (47......AIMS: The clinical management and care of patients with an implantable cardioverter defibrillator (ICD) has shifted from face-to-face in-clinic visits to remote monitoring. Reduced interactions between patients and healthcare professionals may impede patients' transition to adapting post......-implant. We examined patients' needs and preferences for information provision and care options and overall satisfaction with treatment. METHODS AND RESULTS: Patients implanted with a first-time ICD or defibrillator with cardiac resynchronization therapy (n = 389) within the last 2 years at Odense University...

  19. Efficacy of cognitive behavioral therapy in reducing psychiatric symptoms in patients with implantable cardioverter defibrillator: an integrative review.

    Science.gov (United States)

    Maia, A C C O; Braga, A A; Soares-Filho, G; Pereira, V; Nardi, A E; Silva, A C

    2014-04-01

    This article is a systematic review of the available literature on the benefits that cognitive behavioral therapy (CBT) offers patients with implanted cardioverter defibrillators (ICDs) and confirms its effectiveness. After receiving the device, some patients fear that it will malfunction, or they remain in a constant state of tension due to sudden electrical discharges and develop symptoms of anxiety and depression. A search with the key words "anxiety", "depression", "implantable cardioverter", "cognitive behavioral therapy" and "psychotherapy" was carried out. The search was conducted in early January 2013. Sources for the search were ISI Web of Knowledge, PubMed, and PsycINFO. A total of 224 articles were retrieved: 155 from PubMed, 69 from ISI Web of Knowledge. Of these, 16 were written in a foreign language and 47 were duplicates, leaving 161 references for analysis of the abstracts. A total of 19 articles were eliminated after analysis of the abstracts, 13 were eliminated after full-text reading, and 11 articles were selected for the review. The collection of articles for literature review covered studies conducted over a period of 13 years (1998-2011), and, according to methodological design, there were 1 cross-sectional study, 1 prospective observational study, 2 clinical trials, 4 case-control studies, and 3 case studies. The criterion used for selection of the 11 articles was the effectiveness of the intervention of CBT to decrease anxiety and depression in patients with ICD, expressed as a ratio. The research indicated that CBT has been effective in the treatment of ICD patients with depressive and anxiety symptoms. Research also showed that young women represented a risk group, for which further study is needed. Because the number of references on this theme was small, further studies should be carried out.

  20. Influence of time between last myocardial infarction and prophylactic implantable defibrillator implant on device detections and therapies. “Routine Practice” data from the SEARCH MI registry

    Directory of Open Access Journals (Sweden)

    Boriani Giuseppe

    2012-09-01

    Full Text Available Abstract Background A multicenter European Registry, SEARCH-MI, was instituted in the year 2002 in order to assess patients’ outcomes and ICD interventions in patients with a previous MI and depressed LV function, treated with an ICD according to MADIT II results. In this analysis, we evaluate the influence of the time elapsed between last myocardial infarction (MI and prophylactic cardioverter defibrillator (ICD implant on device activations. Methods 643 patients with left ventricular dysfunction (mean LVEF 26 ± 5% and NYHA class I-III were prospectively followed for 1.8 ± 1.2 years in a multicenter registry. The population was divided into 3 groups according to the time between last MI and ICD implant: [1] from 40 days to less than 1.5 years; [2] from 1.5 to less than 7 years and [3] at least 7 years. Results The cumulative incidence of ventricular tachyarrhymias and appropriate device therapy (ATP or shock were higher in patients implanted longer time from last MI (Gray’s Test p = 0.002 and p = 0.013 respectively. No significant differences were seen in all cause mortality (Gray’s Test p = 0.618 or sudden cardiac death across the MI stratification groups (Gray’s Test p = 0.663. Conclusions Patients implanted with an ICD longer after the MI have a higher chance of presenting ventricular tachyarrhythmias and appropriate ICD therapy, while no differences were seen in overall mortality. These observations may be important for improving patient targeting in sudden death prevention.

  1. Effect of Metoprolol Versus Carvedilol on Outcomes in MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy)

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Ruwald, Anne-Christine H; Jøns, Christian;

    2013-01-01

    This study sought to compare the effects of metoprolol and carvedilol in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study.......This study sought to compare the effects of metoprolol and carvedilol in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study....

  2. Efficacy of cognitive behavioral therapy in reducing psychiatric symptoms in patients with implantable cardioverter defibrillator: an integrative review

    Directory of Open Access Journals (Sweden)

    A.C.C.O. Maia

    2014-04-01

    Full Text Available This article is a systematic review of the available literature on the benefits that cognitive behavioral therapy (CBT offers patients with implanted cardioverter defibrillators (ICDs and confirms its effectiveness. After receiving the device, some patients fear that it will malfunction, or they remain in a constant state of tension due to sudden electrical discharges and develop symptoms of anxiety and depression. A search with the key words “anxiety”, “depression”, “implantable cardioverter”, “cognitive behavioral therapy” and “psychotherapy” was carried out. The search was conducted in early January 2013. Sources for the search were ISI Web of Knowledge, PubMed, and PsycINFO. A total of 224 articles were retrieved: 155 from PubMed, 69 from ISI Web of Knowledge. Of these, 16 were written in a foreign language and 47 were duplicates, leaving 161 references for analysis of the abstracts. A total of 19 articles were eliminated after analysis of the abstracts, 13 were eliminated after full-text reading, and 11 articles were selected for the review. The collection of articles for literature review covered studies conducted over a period of 13 years (1998-2011, and, according to methodological design, there were 1 cross-sectional study, 1 prospective observational study, 2 clinical trials, 4 case-control studies, and 3 case studies. The criterion used for selection of the 11 articles was the effectiveness of the intervention of CBT to decrease anxiety and depression in patients with ICD, expressed as a ratio. The research indicated that CBT has been effective in the treatment of ICD patients with depressive and anxiety symptoms. Research also showed that young women represented a risk group, for which further study is needed. Because the number of references on this theme was small, further studies should be carried out.

  3. Response to programmed ventricular stimulation and clinical outcome in cardiac arrest survivors receiving randomised assignment to implantable cardioverter defibrillator or antiarrhythmic drug therapy.

    Science.gov (United States)

    Cappato, Riccardo; Boczor, Sigrid; Kuck, Karl-Heinz

    2004-04-01

    Using a prospective design which randomly assigned implantable cardioverter defibrillator (ICD) versus antiarrhythmic drugs (AADs), we investigated the usefulness of programmed ventricular stimulation (PVS) for prediction of outcome and therapy effectiveness in cardiac arrest (CA) survivors. We performed baseline PVS in 285 survivors of CA enrolled in the Cardiac Arrest Study Hamburg (CASH) and randomised to ICDs or AADs. Sustained ventricular arrhythmia (VA) was induced in 134 (47.0%) patients. We compared the outcomes of different subgroups based on response to baseline PVS and randomly assigned therapy. Patients were followed for a median of 55 months. The raw death rate was greater among inducible (51.3% [95% CI: 44.9-58.3%]) than non-inducible patients (28.8% [CI: 23.4-36.1%, p = 0.0003]). When challenged in a multivariate model, inducibility still had an independent power for predicting all-cause death (hazard ratio (HR), 1.5 [95% CI, 1.1-2.3], p = 0.041), but not sudden death (SD) (HR, 1.2 [95% CI, 0.7-3.6], p = 0.162). Subgroup analysis showed that, when compared to AADs, assignment to ICDs was associated with a lower risk of all-cause death (HR, 0.4 [95% CI, 0.1-0.9], p = 0.044) in patients with EF < or =0.35 and non-inducible arrhythmias, but not in other patient subgroups. In CA survivors, inducibility at baseline PVS is independently associated with an increased risk of all-cause death, but not SD. In addition, response to PVS may help to identify subgroups of patients who could most benefit from ICD.

  4. Arrhythmia detection in single- and dual-chamber implantable cardioverter defibrillators: the more leads, the better?

    Science.gov (United States)

    Francia, Pietro; Balla, Cristina; Uccellini, Arianna; Cappato, Riccardo

    2009-09-01

    The implantable cardioverter defibrillator (ICD) offers life-saving therapies for primary and secondary prevention of sudden cardiac death in high-risk patients. However, ICD detection algorithms consistently misclassify a substantial proportion of supraventricular rhythms, thus carrying the risk for inappropriate therapies. Although single-chamber ICD (Sc-ICD) discrimination tools have been reported to provide high specificity in rejecting sinus tachycardia and atrial fibrillation with a relatively low ventricular rate, accurate recognition of atrial fibrillation with faster ventricular rates, atrial tachycardias, atrial flutter, and some reentrant tachycardias is still an issue. Dual-chamber ICDs (Dc-ICDs) are supposed to overcome specificity issues by enhancing detection algorithms with information derived from the atrial and ventricular timing relationship. The initial promise of Dc-ICDs was to improve detection specificity without compromising sensitivity, and to translate this advantage over Sc-ICDs in a more selective use of aggressive therapies. Despite this solid background, superiority of Dc- over Sc-ICDs has never been convincingly demonstrated. The present review focuses on the efficacy of contemporary ICD arrhythmia discrimination tools and appraises the so far reported evidence supporting the superiority of Dc-ICDs in preventing inappropriate therapies.

  5. Implantable Cardioverter-defibrillator Therapy for Hypertrophic Cardiomyopathy: Usefulness in Primary and Secondary Prevention.

    Science.gov (United States)

    Sarrias, Axel; Galve, Enrique; Sabaté, Xavier; Moya, Àngel; Anguera, Ignacio; Núñez, Elaine; Villuendas, Roger; Alcalde, Óscar; García-Dorado, David

    2015-06-01

    Hypertrophic cardiomyopathy is a frequent cause of sudden death. Clinical practice guidelines indicate defibrillator implantation for primary prevention in patients with 1 or more risk factors and for secondary prevention in patients with a history of aborted sudden death or sustained ventricular arrhythmias. The aim of the present study was to analyze the follow-up of patients who received an implantable defibrillator following the current guidelines in nonreferral centers for this disease. This retrospective observational study included all patients who underwent defibrillator implantation between January 1996 and December 2012 in 3 centers in the province of Barcelona. The study included 69 patients (mean age [standard deviation], 44.8 [17] years; 79.3% men), 48 in primary prevention and 21 in secondary prevention. The mean number of risk factors per patient was 1.8 in the primary prevention group and 0.5 in the secondary prevention group (P=.029). The median follow-up duration was 40.5 months. The appropriate therapy rate was 32.7/100 patient-years in secondary prevention and 1.7/100 patient-years in primary prevention (P<.001). Overall mortality was 10.1%. Implant-related complications were experienced by 8.7% of patients, and 13% had inappropriate defibrillator discharges. In patients with a defibrillator for primary prevention, the appropriate therapy rate is extremely low, indicating the low predictive power of the current risk stratification criteria. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  6. Implantable cardioverter-defibrillator therapy in a 34-year-old patient with eating disorders and after the third sudden cardiac arrest.

    Science.gov (United States)

    Piotrowicz, Ewa; Orzechowski, Piotr; Bilinska, Maria; Przybylski, Andrzej; Szumowski, Lukasz; Piotrowicz, Ryszard

    2015-03-01

    Eating disorders (ED) such as anorexia nervosa and bulimia are psychiatric diseases associated with the highest mortality rate of any other psychiatric disorders. More recently, long-term outcome studies with follow-up of over 20 years report a mortality of between 15% and 18% (Casiero and Frishman, Cardiol Rev 14(5), 227, 2006). The sudden death secondary to arrhythmias is often the cause of death in these patients (Casiero and Frishman, Cardiol Rev 14(5), 227, 2006). A case of life-threatening ventricular arrhythmia (VA) in a patient with ED is presented. Clinical records (cardiologic, psychiatric), electrocardiograms, echocardiogram, coronary angiogram, cardiac magnetic resonance, and endocrine diagnostics were performed. Finally a cardioverter-defibrillator (ICD) was implanted in the patient after her third cardiac arrest. An optimal approach to antiarrhythmic therapy in such patients is a real challenge for a cardiologist.

  7. The Entirely Subcutaneous Defibrillator – A New Generation and Future Expectations

    Science.gov (United States)

    Ali, Hussam; Lupo, Pierpaolo; Cappato, Riccardo

    2015-01-01

    Although conventional implantable cardioverter-defibrillators (ICDs) have proved effective in the prevention of sudden cardiac death (SCD), they still appear to be limited by non-trivial acute and long-term complications. The recent advent of an entirely subcutaneous ICD (S-ICD) represents a further step in the evolution of defibrillation technology towards a less-invasive approach. This review highlights some historical and current issues concerning the S-ICD that may offer a viable therapeutic option in selected patients at high risk of SCD and in whom pacing is not required. After the CE Mark and US Food and Drug Administration (FDA) approvals, the S-ICD is being implanted worldwide with growing clinical data regarding its safety and efficacy (the EFFORTLESS Registry). The recently developed new generation of S-ICD (EMBLEM, Boston Scientific) demonstrates favourable features including a smaller device, longer longevity and remote-monitoring compatibility. Further innovations in the S-ICD system and potential integration with leadless pacing may play an important role in defibrillation therapy and prevention of SCD in the near future. PMID:26835112

  8. The Clinical Application and Effect of Implantable Cardioverter Defibrillator(ICD)%经静脉植入埋藏式心脏复律除颤器的临床应用及效果观察

    Institute of Scientific and Technical Information of China (English)

    江自强

    2015-01-01

    Objective:to explore the clinical application and effect of implantable cardioverter defibrillator(icd). Methods:selecting and analyzing 80 cases of malignant ventricular arrhythmia, which are randomly divided into control group (treated with amiodarone) and treatment group(treated with the icd) . then comparing the effects. Results:the overall response rate(rr) of the treatment group is 95%, much higher than the other one(85%)(P0.05);yet after treatment, the heart rate of the treatment group is signiifcantly lower than the control group (P0.05);实验组治疗后心率,显著低于对照组(P<0.05);实验组治疗后Pr间期,显著高于对照组(P<0.05)。结论恶性室性心律失常采用静脉植入埋藏式心脏复律除颤器治疗效果理想,值得推广应用。

  9. Concerns about the implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van Domburg, Ron T; Theuns, Dominic A M J

    2005-01-01

    Patients with an implantable cardioverter defibrillator (ICD) are at increased risk of anxiety disorders. In turn, anxiety has been identified as a precipitant of ventricular arrhythmias. Anxiety may in part be attributed to concerns about the ICD firing, but the relationship between ICD concerns...

  10. Defibrillator Implantation in Patients with Nonischemic Systolic Heart Failure

    DEFF Research Database (Denmark)

    Køber, Lars; Thune, Jens J; Nielsen, Jens C

    2016-01-01

    BACKGROUND: The benefit of an implantable cardioverter-defibrillator (ICD) in patients with symptomatic systolic heart failure caused by coronary artery disease has been well documented. However, the evidence for a benefit of prophylactic ICDs in patients with systolic heart failure that is not due.......6%) in the control group (P=0.29). CONCLUSIONS: In this trial, prophylactic ICD implantation in patients with symptomatic systolic heart failure not caused by coronary artery disease was not associated with a significantly lower long-term rate of death from any cause than was usual clinical care. (Funded...... to coronary artery disease has been based primarily on subgroup analyses. The management of heart failure has improved since the landmark ICD trials, and many patients now receive cardiac resynchronization therapy (CRT). METHODS: In a randomized, controlled trial, 556 patients with symptomatic systolic heart...

  11. Concomitant Use of the Subcutaneous Implantable Cardioverter Defibrillator and a Permanent Pacemaker.

    Science.gov (United States)

    Huang, Jason; Patton, Kristen K; Prutkin, Jordan M

    2016-11-01

    The subcutaneous implantable cardioverter defibrillator (S-ICD) is a novel implanted defibrillator for the prevention of sudden cardiac death that avoids intravascular access. Use of this device is limited by its inability to provide backup pacing. Combined use of the S-ICD with a permanent pacemaker may be the optimal choice in certain situations though experience with the use of both devices together remains limited. We reviewed our single-center experience with the S-ICD from March 2011 to November 2015. Four patients with concomitant use of the S-ICD and a permanent pacemaker were identified. Clinical indication for device therapy, operative details, and subsequent follow-up was reviewed. During implantation, S-ICD sensing of paced morphologies was evaluated at maximal voltage output. After S-ICD implant, if feasible, the upper rate was adjusted to ≤50% of the S-ICD tachycardia zone to minimize risk of inappropriate shocks. After a mean follow-up of over 1 year, no adverse events occurred, including no inappropriate shock, lead malfunction, or device infection. One patient had a total of eight appropriate shocks, while another individual had no inappropriate shocks despite having a unipolar pacing lead. In unique situations, combined use of the S-ICD and a permanent pacemaker may be preferable to alternative options. In our experience, this approach was successful in varying conditions including complex congenital heart disease, recurrent device infection, and limited vascular access. © 2016 Wiley Periodicals, Inc.

  12. Defibrillator implantation early after myocardial infarction.

    Science.gov (United States)

    Steinbeck, Gerhard; Andresen, Dietrich; Seidl, Karlheinz; Brachmann, Johannes; Hoffmann, Ellen; Wojciechowski, Dariusz; Kornacewicz-Jach, Zdzisława; Sredniawa, Beata; Lupkovics, Géza; Hofgärtner, Franz; Lubinski, Andrzej; Rosenqvist, Mårten; Habets, Alphonsus; Wegscheider, Karl; Senges, Jochen

    2009-10-08

    The rate of death, including sudden cardiac death, is highest early after a myocardial infarction. Yet current guidelines do not recommend the use of an implantable cardioverter-defibrillator (ICD) within 40 days after a myocardial infarction for the prevention of sudden cardiac death. We tested the hypothesis that patients at increased risk who are treated early with an ICD will live longer than those who receive optimal medical therapy alone. This randomized, prospective, open-label, investigator-initiated, multicenter trial registered 62,944 unselected patients with myocardial infarction. Of this total, 898 patients were enrolled 5 to 31 days after the event if they met certain clinical criteria: a reduced left ventricular ejection fraction ( or = 150 beats per minute) during Holter monitoring (criterion 2: 208 patients), or both criteria (88 patients). Of the 898 patients, 445 were randomly assigned to treatment with an ICD and 453 to medical therapy alone. During a mean follow-up of 37 months, 233 patients died: 116 patients in the ICD group and 117 patients in the control group. Overall mortality was not reduced in the ICD group (hazard ratio, 1.04; 95% confidence interval [CI], 0.81 to 1.35; P=0.78). There were fewer sudden cardiac deaths in the ICD group than in the control group (27 vs. 60; hazard ratio, 0.55; 95% CI, 0.31 to 1.00; P=0.049), but the number of nonsudden cardiac deaths was higher (68 vs. 39; hazard ratio, 1.92; 95% CI, 1.29 to 2.84; P=0.001). Hazard ratios were similar among the three groups of patients categorized according to the enrollment criteria they met (criterion 1, criterion 2, or both). Prophylactic ICD therapy did not reduce overall mortality among patients with acute myocardial infarction and clinical features that placed them at increased risk. (ClinicalTrials.gov number, NCT00157768.) 2009 Massachusetts Medical Society

  13. The effects of nifekalant hydrochloride on the spatial dispersion of repolarization after direct current defibrillation in patients with oral amiodarone and β-blocker therapy

    Directory of Open Access Journals (Sweden)

    Keiko Maeda

    2014-06-01

    Conclusions: NIF suppressed the deterioration of the SDR after ICD shock. This might be one of the mechanisms by which NIF suppresses recurrence of ventricular tachyarrhythmia just after ICD shock in patients with oral amiodarone and β-blocker therapy.

  14. Persistence of ICD indication at the time of replacement in patients with initial implant for primary prevention indication: Effect on subsequent ICD therapies

    Directory of Open Access Journals (Sweden)

    Gabriele Dell’Era

    2017-03-01

    Conclusion: In heart failure with reduced LVEF, ICD indication persisted at the time of GR in 69% of patients. However, even in the absence of persistent ICD indication at GR, the risk of recurrence of arrhythmic events was not null.

  15. Longevity of the Subcutaneous Implantable Defibrillator Long-Term Follow-Up of the European Regulatory Trial Cohort

    NARCIS (Netherlands)

    Theuns, Dominic A. M. J.; Crozier, Ian G.; Barr, Craig S.; Hood, Margaret A.; Cappato, Riccardo; Knops, Reinoud E.; Maass, Alexander H.; Boersma, Lucas V. A.; Jordaens, Luc

    2015-01-01

    Background The recent advent of subcutaneous implantable cardioverter defibrillators (S-ICDs) has provided investigators with a safe and effective new therapy in patients at risk of sudden cardiac death. At present, no data are available with regard to the longevity of these new devices. This study

  16. Impact of left ventricular ejection fraction on occurrence of ventricular events in defibrillator patients with coronary artery disease

    NARCIS (Netherlands)

    B. Schaer (Beat); C. Sticherling (Christian); T. Szili-Torok (Tamas); S. Osswald (Stefan); L.J.L.M. Jordaens (Luc); D.A.M.J. Theuns (Dominic)

    2011-01-01

    textabstractAims Primary preventive implantable cardioverter defibrillator (ICD) therapy is indicated in patients with coronary artery disease (CAD) and left ventricular ejection fraction (LVEF) of ≤35, but some patients in the major trials had LVEF in the range of 3035. We hypothesized that these

  17. Longevity of implantable cardioverter-defibrillators for cardiac resynchronization therapy in current clinical practice: an analysis according to influencing factors, device generation, and manufacturer.

    Science.gov (United States)

    Landolina, Maurizio; Curnis, Antonio; Morani, Giovanni; Vado, Antonello; Ammendola, Ernesto; D'onofrio, Antonio; Stabile, Giuseppe; Crosato, Martino; Petracci, Barbara; Ceriotti, Carlo; Bontempi, Luca; Morosato, Martina; Ballari, Gian Paolo; Gasparini, Maurizio

    2015-08-01

    Device replacement at the time of battery depletion of implantable cardioverter-defibrillators (ICDs) may carry a considerable risk of complications and engenders costs for healthcare systems. Therefore, ICD device longevity is extremely important both from a clinical and economic standpoint. Cardiac resynchronization therapy defibrillators (CRT-D) battery longevity is shorter than ICDs. We determined the rate of replacements for battery depletion and we identified possible determinants of early depletion in a series of patients who had undergone implantation of CRT-D devices. We retrieved data on 1726 consecutive CRT-D systems implanted from January 2008 to March 2010 in nine centres. Five years after a successful CRT-D implantation procedure, 46% of devices were replaced due to battery depletion. The time to device replacement for battery depletion differed considerably among currently available CRT-D systems from different manufacturers, with rates of batteries still in service at 5 years ranging from 52 to 88% (log-rank test, P < 0.001). Left ventricular lead output and unipolar pacing configuration were independent determinants of early depletion [hazard ratio (HR): 1.96; 95% 95% confidence interval (CI): 1.57-2.46; P < 0.001 and HR: 1.58, 95% CI: 1.25-2.01; P < 0.001, respectively]. The implantation of a recent-generation device (HR: 0.57; 95% CI: 0.45-0.72; P < 0.001), the battery chemistry and the CRT-D manufacturer (HR: 0.64; 95% CI: 0.47-0.89; P = 0.008) were additional factors associated with replacement for battery depletion. The device longevity at 5 years was 54%. High left ventricular lead output and unipolar pacing configuration were associated with early battery depletion, while recent-generation CRT-Ds displayed better longevity. Significant differences emerged among currently available CRT-D systems from different manufacturers. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  18. Implantable cardioverter defibrillator specific rehabilitation improves health cost outcomes

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Zwisler, Ann-Dorthe; Koch, Mette Bjerrum;

    2015-01-01

    ) were randomized (1:1) to comprehensive cardiac rehabilitation or usual care. Outcomes were measured by implantable cardioverter defibrillator therapy history from patient records and national register follow-up on mortality, hospital admissions and costs. RESULTS: No significant differences were found...... was -6,789 USD/-5,593 Euro in favour of rehabilitation. CONCLUSION: No long-term health outcome benefits were found for the rehabilitation programme. However, the rehabilitation programme resulted in a reduction in total attributable direct costs.......OBJECTIVE: The Copenhagen Outpatient ProgrammE - implantable cardioverter defibrillator (COPE-ICD) trial included patients with implantable cardioverter defibrillators in a randomized controlled trial of rehabilitation. After 6-12 months significant differences were found in favour...

  19. Long-term efficacy of implantable cardiac resynchronization therapy plus defibrillator for primary prevention of sudden cardiac death in patients with mild heart failure: an updated meta-analysis.

    Science.gov (United States)

    Sun, Wei-Ping; Li, Chun-Lei; Guo, Jin-Cheng; Zhang, Li-Xin; Liu, Ran; Zhang, Hai-Bin; Zhang, Ling

    2016-07-01

    Previous studies of implantable cardiac resynchronization therapy plus defibrillator (CRT-D) therapy used for primary prevention of sudden cardiac death have suggested that CRT-D therapy is less effective in patients with mild heart failure and a wide QRS complex. However, the long-term benefits are variable. We performed a meta-analysis of randomized trials identified in systematic searches of MEDLINE, EMBASE, and the Cochrane Database. Three studies (3858 patients) with a mean follow-up of 66 months were included. Overall, CRT-D therapy was associated with significantly lower all-cause mortality than was implantable cardioverter defibrillator (ICD) therapy (OR, 0.78; 95 % CI, 0.63-0.96; P = 0.02; I (2) = 19 %). However, the risk of cardiac mortality was comparable between two groups (OR, 0.74; 95 % CI, 0.53-1.01; P = 0.06). CRT-D treatment was associated with a significantly lower risk of hospitalization for heart failure (OR, 0.67; 95 % CI, 0.50-0.89; P = 0.005; I (2) = 55 %). The composite outcome of all-cause mortality and hospitalization for heart failure was also markedly lower with CRT-D therapy than with ICD treatment alone (OR, 0.67; 95 % CI, 0.57-0.77; P failure events in patients with mild heart failure with a wide QRS complex. However, long-term risk of cardiac mortality was similar between two groups. More randomized studies are needed to confirm these findings, especially in patients with NYHA class I heart failure or patients without LBBB.

  20. A review of economic evaluation models for cardiac resynchronization therapy with implantable cardioverter defibrillators in patients with heart failure

    NARCIS (Netherlands)

    Tomini, F.; van Asselt, A. D.

    2012-01-01

    OBJECTIVES: Cardiac resynchronization therapy with biventricular pacemaker (CRT-P) is considered an effective treatment for heart failure (HF). Adding implantable cardioverter defibrillators (CRT-D) may further reduce the risk of sudden cardiac death (SCD). However, economic evaluations have shown t

  1. Reliability of clinical ICD-10 diagnoses among electroconvulsive therapy patients with chronic affective disorders

    Directory of Open Access Journals (Sweden)

    Klaus Damgaard Jakobsen

    2008-09-01

    Full Text Available Background and Objectives: Diagnostic reliability is of major concern both to clinicians and researchers. The aim has been to investigate the trustworthiness of clinical ICD-10 affective disorder diagnoses for research purpose. Methods: 150 ECT patients with chronic affective disorders were investigated. A standardized schema for basic anamnesis and the Operational Criteria Checklist for Psychotic and Affective Illness (OPCRIT were used. The sensitivity, specificity, positive and negative predictive values of clinical affective disorder ICD-10 diagnoses and the formal agreement between clinical ICD-10, OPCRIT ICD-10 and DSM-IV diagnoses were determined using unweighted κ-statistics. Results: The sensitivity, specificity, positive and negative predictive values of the clinical bipolar diagnoses was 0.55, 0.75, 0.42 and 0.84, respectively. The sensitivity, specificity, positive and negative predictive values of the clinical unipolar diagnoses was 0.79, 0.55, 0.77 and 0.58, respectively. The agreement between clinical ICD-10 and OPCRIT ICD-10 bipolar vs. non-bipolar diagnoses was low, κ = 0.28. The agreement between clinical ICD-10 and OPCRIT ICD-10 unipolar vs. non-unipolar diagnoses was low, κ = 0.35. The agreement between OPCRIT ICD-10 and DSM-IV diagnoses on bipolar vs. non-bipolar disorders was high, κ = 0.91, and the agreement on unipolar vs. non-unipolar disorders was fairly high, κ = 0.78. Conclusions: This study demonstrates that the reliability of clinical ICD-10 diagnoses of affective disorders from chronic subjects with a history of ECT is problematic despite sample homogeneity on basic clinical, demographic and epidemiological parameters.

  2. Optimal tachycardia programming in ICDs : Recommendations in the post-MADIT-RIT era.

    Science.gov (United States)

    Israel, Carsten W; Burmistrava, Tatsiana

    2016-09-01

    Optimal implantable cardioverter-defibrillator (ICD) programming can reduce the incidence of inappropriate shock therapy and improve prognosis in patients with an ICD. Only after results from randomized trials became available was the "safety first" feeling overcome that mandated early shock therapy, waived the use of antitachycardia pacing and forced shock therapy after a time of 30 s expired, even if tachycardia discriminators would have withheld the therapy. The strong evidence to limit ICD therapy to longer ventricular tachycardia (VT) should not result in individually dangerous ICD programming, particularly in patients with a high risk of slow VT (known monomorphic VT, post VT ablation, during treatment with amiodarone, very dilated left ventricle). Monitoring zones may aid to detect unexpected slow VT and to explain symptoms such as presyncope without exposing the patient to an unnecessary risk of inappropriate therapy. This review summarizes our current knowledge on optimal ICD programming and explains exactly how we should program device parameters in practice in single- or dual-chamber ICDs by different manufacturers and in different groups of patients.

  3. Dental management of a patient fitted with subcutaneous Implantable Cardioverter Defibrillator device and concomitant warfarin treatment.

    Science.gov (United States)

    Shah, Altaf Hussain; Khalil, Hesham Saleh; Kola, Mohammed Zaheer

    2015-07-01

    Automated Implantable Cardioverter Defibrillators (AICD), simply known as an Implantable Cardioverter Defibrillator (ICD), has been used in patients for more than 30 years. An Implantable Cardioverter Defibrillator (ICD) is a small battery-powered electrical impulse generator that is implanted in patients who are at a risk of sudden cardiac death due to ventricular fibrillation, ventricular tachycardia or any such related event. Typically, patients with these types of occurrences are on anticoagulant therapy. The desired International Normalized Ratio (INR) for these patients is in the range of 2-3 to prevent any subsequent cardiac event. These patients possess a challenge to the dentist in many ways, especially during oral surgical procedures, and these challenges include risk of sudden death, control of post-operative bleeding and pain. This article presents the dental management of a 60 year-old person with an ICD and concomitant anticoagulant therapy. The patient was on multiple medications and was treated for a grossly neglected mouth with multiple carious root stumps. This case report outlines the important issues in managing patients fitted with an ICD device and at a risk of sudden cardiac death.

  4. Covering sleeves can shield the high-voltage coils from lead chatter in an integrated bipolar ICD lead.

    Science.gov (United States)

    Cooper, Joshua M; Sauer, William H; Garcia, Fermin C; Krautkramer, Michael J; Verdino, Ralph J

    2007-02-01

    Integrated bipolar implantable cardioverter-defibrillator (ICD) leads use the distal high-voltage coil as both the ventricular sensing anode and the distal shocking electrode. Mechanical interactions between the distal ICD coil and other intracardiac leads have been reported to result in electrical oversensing and inappropriate ICD therapies. We sought to determine whether covering sleeves over the high-voltage coils of an integrated bipolar ICD lead could prevent sensed artefact from mechanical lead interactions. Endotak Reliance 0157 and Endotak Reliance-G 0185 leads, the latter with expanded polytetrafluoroethylene (ePTFE) sleeves covering the high-voltage coils, were connected to ICD generators and the leads were submerged in saline. Device programmers were used to communicate with the ICD generators, providing real-time electrogram recording throughout testing. A series of mechanical interactions were performed with the ICD leads, including sliding and striking each distal coil against metal and non-metal components of other ICD and pacemaker leads. All direct metal-metal interactions resulted in sensed electrical artefact, including interactions between the bare ICD coil and another bare ICD coil or metal pacemaker ring. Identical mechanical interactions where metal-metal contact was prevented due to an interposed ePTFE covering sleeve were electrically silent with no sensed artefact. A covering sleeve over the distal high-voltage coil of an integrated bipolar ICD lead can mechanically shield the lead from metal-metal interactions, which might otherwise result in sensed artefact and inappropriate ICD therapies or withholding of pacing output. This finding has implications for lead selection when a new ICD lead is to be implanted adjacent to abandoned intracardiac leads or lead fragments.

  5. Inappropriate shocks in the subcutaneous ICD

    DEFF Research Database (Denmark)

    Olde Nordkamp, Louise R A; Brouwer, Tom F; Barr, Craig

    2015-01-01

    shocks have been reported. METHODS: We analyzed the incidence, predictors and management of inappropriate shocks in the EFFORTLESS S-ICD Registry, which collects S-ICD implantation information and follow-up data from clinical centers in Europe and New Zealand. RESULTS: During a follow-up of 21 ± 13......BACKGROUND: The entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) eliminates the need for transvenous leads, and therefore has the potential to improve lead-longevity and reduce lead-related complications. The S-ICD has a morphology-based sensing algorithm of which inappropriate...

  6. An Entirely Subcutaneous Implantable Cardioverter-Defibrillator

    NARCIS (Netherlands)

    Bardy, Gust H.; Smith, Warren M.; Hood, Margaret A.; Crozier, Ian G.; Melton, Iain C.; Jordaens, Luc; Theuns, Dominic; Park, Robert E.; Wright, David J.; Connelly, Derek T.; Fynn, Simon P.; Murgatroyd, Francis D.; Sperzel, Johannes; Neuzner, Joerg; Spitzer, Stefan G.; Ardashev, Andrey V.; Oduro, Amo; Boersma, Lucas; Maass, Alexander H.; Van Gelder, Isabelle C.; Wilde, Arthur A.; van Dessel, Pascal F.; Knops, Reinoud E.; Barr, Craig S.; Lupo, Pierpaolo; Cappato, Riccardo; Grace, Andrew A.

    2010-01-01

    BACKGROUND Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS First, we conducted tw

  7. An entirely subcutaneous implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    G.H. Bardy (Gust); W.M. Smith (Warren); A.M. Hood (Margaret); I.G. Crozier (Ian); I.C. Melton (Iain Craig); L.J.L.M. Jordaens (Luc); D.A.M.J. Theuns (Dominic); E. Park (Robert); D.J. Wright (David Justin); D.T. Connelly (Derek); S.P. Fynn (Simon Patrick); F.D. Murgatroyd (Francis); J. Sperzel (Johannes); J. Neuzner (Jörg); S.G. Spitzer (Stefan); A.V. Ardashev (Andrey); A. Oduro (Amo); L. Boersma (Lucas); A.H. Maass (Alexander); I.C. van Gelder (Isabelle); A.A.M. Wilde (Arthur); P.F.H.M. van Pascal; R.E. Knops (Reinoud); C.S. Barr (Craig); P. Lupo (Pierpaolo); R. Cappato (Riccardo); A.A. Grace (Andrew)

    2010-01-01

    textabstractBACKGROUND: Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS: First, w

  8. An entirely subcutaneous implantable cardioverter-defibrillator

    NARCIS (Netherlands)

    G.H. Bardy (Gust); W.M. Smith (Warren); A.M. Hood (Margaret); I.G. Crozier (Ian); I.C. Melton (Iain Craig); L.J.L.M. Jordaens (Luc); D.A.M.J. Theuns (Dominic); E. Park (Robert); D.J. Wright (David Justin); D.T. Connelly (Derek); S.P. Fynn (Simon Patrick); F.D. Murgatroyd (Francis); J. Sperzel (Johannes); J. Neuzner (Jörg); S.G. Spitzer (Stefan); A.V. Ardashev (Andrey); A. Oduro (Amo); L. Boersma (Lucas); A.H. Maass (Alexander); I.C. van Gelder (Isabelle); A.A.M. Wilde (Arthur); P.F.H.M. van Pascal; R.E. Knops (Reinoud); C.S. Barr (Craig); P. Lupo (Pierpaolo); R. Cappato (Riccardo); A.A. Grace (Andrew)

    2010-01-01

    textabstractBACKGROUND: Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS: First,

  9. An Entirely Subcutaneous Implantable Cardioverter-Defibrillator

    NARCIS (Netherlands)

    Bardy, Gust H.; Smith, Warren M.; Hood, Margaret A.; Crozier, Ian G.; Melton, Iain C.; Jordaens, Luc; Theuns, Dominic; Park, Robert E.; Wright, David J.; Connelly, Derek T.; Fynn, Simon P.; Murgatroyd, Francis D.; Sperzel, Johannes; Neuzner, Joerg; Spitzer, Stefan G.; Ardashev, Andrey V.; Oduro, Amo; Boersma, Lucas; Maass, Alexander H.; Van Gelder, Isabelle C.; Wilde, Arthur A.; van Dessel, Pascal F.; Knops, Reinoud E.; Barr, Craig S.; Lupo, Pierpaolo; Cappato, Riccardo; Grace, Andrew A.

    2010-01-01

    BACKGROUND Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS First, we conducted

  10. [The implantable cardioverter-defibrillator: sometimes necessary

    NARCIS (Netherlands)

    Smeets, J.L.R.M.

    2004-01-01

    The implantable cardioverter-defibrillator (ICD) is used in patients who are at risk for ventricular fibrillation after having suffered from a myocardial infarction. Initially, patient selection was limited to survivors of impending sudden death with coronary artery disease. Later, ICD implantation

  11. Pre-implantation implantable cardioverter defibrillator concerns and Type D personality increase the risk of mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Erdman, Ruud A M;

    2010-01-01

    Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients.......Little is known about the influence of psychological factors on prognosis in implantable cardioverter defibrillator (ICD) patients. We examined the influence of the distressed personality (Type D) and pre-implantation device concerns on short-term mortality in ICD patients....

  12. Shock whilst gardening--implantable defibrillators & lawn mowers.

    Science.gov (United States)

    Von Olshausen, G; Lennerz, C; Grebmer, C; Pavaci, H; Kolb, C

    2014-02-01

    Electromagnetic interference with implantable cardioverter defibrillators (ICDs) can cause inappropriate shock delivery or temporary inhibition of ICD functions. We present a case of electromagnetic interference between a lawn mower and an ICD resulting in an inappropriate discharge of the device due to erroneous detection of ventricular fibrillation.

  13. Additional coronary sinus shocking lead as rescue therapy after multiple internal and external defibrillation failures.

    Science.gov (United States)

    Chauveau, Samuel; Dulac, Arnaud; Sebbag, Laurent; Morel, Elodie; Chevalier, Philippe

    2017-06-01

    High defibrillation threshold (DFT) and defibrillation failure can lead to intractable ventricular arrhythmias. Additional coronary sinus coil is an effective strategy to achieve marked reduction in DFT. However, physicians should retain this might prevent future coronary sinus lead placement in case the patient would develop complete left bundle branch block.

  14. [Clinical development of the automatic implantable defibrillator over 35 years: A success story].

    Science.gov (United States)

    Steinbeck, G

    2015-06-01

    After 12 years of development and experimental evaluation, the first automatic implantable cardioverter-defibrillator (ICD) was implanted in man on February 4, 1980. This overview describes the technical and functional developments over 35 years from a simple shock-box, weighing 292 g, to the sophisticated 80 g device of today, delivering graded therapy to sustained ventricular arrhythmias and biventricular stimulation to treat heart failure. Finally, a special tribute is given to Michel Mirowski, one of the inventors of the ICD, as scientist and physician dedicated to patient care.

  15. Somatosensory amplification mediates sex differences in psychological distress among cardioverter-defibrillator patients

    DEFF Research Database (Denmark)

    Versteeg, Henneke; Baumert, Jens; Kolb, Christof

    2010-01-01

    The present study examined whether female patients with an implantable cardioverter defibrillator (ICD) report more psychological distress than male patients, and whether somatosensory amplification mediates this relationship. Design: Consecutive ICD patients (N = 241; 33% women) participating in...

  16. Prognostic importance of distressed (Type D) personality and shocks in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Denollet, Johan; Tekle, Fetene B; Pedersen, Susanne S.;

    2013-01-01

    Clinical trials have shown the benefit of implantable cardioverter defibrillator (ICD) treatment. In this study, we examined the importance of chronic psychological distress and device shocks among ICD patients seen in clinical practice....

  17. Association of psychiatric history and type D personality with symptoms of anxiety, depression, and health status prior to ICD implantation

    DEFF Research Database (Denmark)

    Starrenburg, Annemieke H; Kraaier, Karin; Pedersen, Susanne S.

    2013-01-01

    Personality factors and psychiatric history may help explain individual differences in risk of psychological morbidity and poor health outcomes in patients with an implantable cardioverter defibrillator (ICD)....

  18. Low Energy Multi-Stage Atrial Defibrillation Therapy Terminates Atrial Fibrillation with Less Energy than a Single Shock

    Science.gov (United States)

    Li, Wenwen; Janardhan, Ajit H.; Fedorov, Vadim V.; Sha, Qun; Schuessler, Richard B.; Efimov, Igor R.

    2011-01-01

    Background Implantable device therapy of atrial fibrillation (AF) is limited by pain from high-energy shocks. We developed a low-energy multi-stage defibrillation therapy and tested it in a canine model of AF. Methods and Results AF was induced by burst pacing during vagus nerve stimulation. Our novel defibrillation therapy consisted of three stages: ST1 (1-4 low energy biphasic shocks), ST2 (6-10 ultra-low energy monophasic shocks), and ST3 (anti-tachycardia pacing). Firstly, ST1 testing compared single or multiple monophasic (MP) and biphasic (BP) shocks. Secondly, several multi-stage therapies were tested: ST1 versus ST1+ST3 versus ST1+ST2+ST3. Thirdly, three shock vectors were compared: superior vena cava to distal coronary sinus (SVC>CSd), proximal coronary sinus to left atrial appendage (CSp>LAA) and right atrial appendage to left atrial appendage (RAA>LAA). The atrial defibrillation threshold (DFT) of 1BP shock was less than 1MP shock (0.55 ± 0.1 versus 1.38 ± 0.31 J; p =0.003). 2-3 BP shocks terminated AF with lower peak voltage than 1BP or 1MP shock and with lower atrial DFT than 4 BP shocks. Compared to ST1 therapy alone, ST1+ST3 lowered the atrial DFT moderately (0.51 ± 0.46 versus 0.95 ± 0.32 J; p = 0.036) while a three-stage therapy, ST1+ST2+ST3, dramatically lowered the atrial DFT (0.19 ± 0.12 J versus 0.95 ± 0.32 J for ST1 alone, p=0.0012). Finally, the three-stage therapy ST1+ST2+ST3 was equally effective for all studied vectors. Conclusions Three-stage electrotherapy significantly reduces the AF defibrillation threshold and opens the door to low energy atrial defibrillation at or below the pain threshold. PMID:21980076

  19. Anxiety and risk of ventricular arrhythmias or mortality in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Pedersen, Susanne S.; van den Broek, Krista C;

    2013-01-01

    A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences anxiety after device implantation. The purpose of the present study was to evaluate whether anxiety is predictive of ventricular arrhythmias and all-cause mortality 1 year post ICD implantation.......A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences anxiety after device implantation. The purpose of the present study was to evaluate whether anxiety is predictive of ventricular arrhythmias and all-cause mortality 1 year post ICD implantation....

  20. Reliability of clinical ICD-10 diagnoses among electroconvulsive therapy patients with chronic affective disorders

    DEFF Research Database (Denmark)

    Jakobsen, Klaus Damgaard; Hansen, Thomas Folkmann; Dam, Henrik

    2008-01-01

    Background and Objectives: Diagnostic reliability is of major concern both to clinicians and researchers. The aim has been to investigate the trustworthiness of clinical ICD-10 affective disorder diagnoses for research purpose. Methods: 150 ECT patients with chronic affective disorders were inves...

  1. Importance of ventricular tachycardia storms not terminated by implantable cardioverter defibrillators shocks in patients with CASQ2 associated catecholaminergic polymorphic ventricular tachycardia.

    Science.gov (United States)

    Marai, Ibrahim; Khoury, Asaad; Suleiman, Mahmoud; Gepstein, Lior; Blich, Miri; Lorber, Abraham; Boulos, Monther

    2012-07-01

    In this study, the clinical and implantable cardioverter-defibrillator (ICD)-related follow-up of patients with catecholaminergic polymorphic ventricular tachycardia (CPVT) with homogenous missense mutations in CASQ2 was summarized. Patients were followed in a pediatric cardiology clinic and an ICD clinic. All patients were treated with high-dose β blockers. ICDs were recommended for patients who remained symptomatic despite medical treatment. Twenty-seven patients were followed for 1 to 15 years (median 9). Twenty patients (74%) were symptomatic at diagnosis; 13 (65%) remained symptomatic after treatment with high-dose β blockers and thus were advised to receive ICDs. Eight of these patients refused ICDs, and eventually 6 (75%) died suddenly. Four of the 5 patients who received ICDs had ventricular tachycardia storms treated but not terminated by recurrent ICD shocks. These ventricular tachycardia storms (2 episodes in 2 patients and 1 episode in 2 patient) terminated spontaneously after finishing the programmed ICD shocks, without degeneration to ventricular fibrillation. None of the patients who received ICDs died. In conclusion, patients with CASQ2-associated CPVT should be recommended to receive ICDs to prevent sudden death when medical therapy is not effective. These patients may have recurrent ventricular tachycardia storms treated but not terminated by recurrent ICD shocks, without degeneration to ventricular fibrillation. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Role of implantable cardioverter defibrillator therapy in patients with long QT syndrome%植入型心律转复除颤器在长QT综合征患者中的应用

    Institute of Scientific and Technical Information of China (English)

    孙奇; 陈柯萍; 陈若菡; 华伟; 浦介麟; 张澍

    2008-01-01

    Objective To observe the role of implantable cardioverter defibrillator (ICD) therapy in patients with long QT syndrome. Methods ICD were planted in eight patients [4 men,4 women, mean age (27.3±25.9) years] with long QT syndrome. In the follow-up,the parameters of ICD were adjusted according to ICD therapy. Result During the follow-up of (27.3±25.9)months, ICD recorded 101 VT/VF episodes in 3 patients. With the traditional ICD programming,44 VF episodes were recorded. After the device parameters were adjusted according the VF episodes,57 VT and 2 VF episodes were recorded,most of them serf-terminated or terminated by low-energy shock. Electrical storm was presented in a patient,and we terminated it by increas-ing the base pacing rate. Inappropriate shocks due to T-wave oversensing were found in two patients,and it was avoided through adjusting the post-sensed Decay Delay. Conclusion Optimal device programming according to ICD therapy significantly decreases inappropriate ICD shocks and fewer unnecessary battery depletion and un-necessary shocks.%目的 总结阜外心血管病医院应用植入型心律转复除颤器(ICD)治疗长QT综合征(LQTS)患者的经验.方法 8例LQTS患者接受了ICD治疗,平均年龄(38.9±16.7)岁.在随访期间,根据具体情况,调整ICD的各项程控参数.结果 平均随访(27.3±25.9)个月,有3例患者出现了101次室性心动过速/心室颤动(VT/VF)事件.在出厂程控参数下,共记录到44次VF事件.重新设置VT/VF的识别及治疗参数后,共记录到57次VT事件,2次VF事件,大部分自行终止或经低能量转复成功.1例患者术后出现了电风暴,通过快速心室起搏,终止了尖端扭转性室性心动过速(Tdp)的反复发作.2例患者发生了因T波误感知导致的ICD误放电,通过延长感知灵敏度自动调整延迟,从而避免了T波误感知.结论 针对LQTS患者的发病特点,调整ICD的程控参数,可以提高疗效并减少ICD误放电.

  3. Effect of Cardiac Rehabilitation in Patients with ICD

    DEFF Research Database (Denmark)

    Christensen, Anne Vinggaard; Zwisler, Ann-Dorthe; Svendsen, Jesper Hastrup

    2015-01-01

    BACKGROUND: The COPE-ICD (Copenhagen Outpatient ProgrammE-implantable cardioverter defibrillator) trial studied comprehensive cardiac rehabilitation for patients with ICDs. The purpose of this paper was to explore: (1) gender differences in self-rated health and quality of life (QoL) at hospital ...

  4. Worldwide experience with a totally subcutaneous implantable defibrillator

    DEFF Research Database (Denmark)

    Lambiase, Pier D; Barr, Craig; Theuns, Dominic A M J

    2014-01-01

    AIMS: The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large internationa...... event rates and inappropriate shock rates comparable with those reported for conventional ICDs. Clinical trial registration URL: http://www.clinicaltrials.gov. Unique identifier NCT01085435....

  5. Sensing and detection in Medtronic implantable cardioverter defibrillators.

    Science.gov (United States)

    Brown, Mark L; Swerdlow, Charles D

    2016-09-01

    Ensuring sensing and detection of ventricular tachycardia (VT) and ventricular fibrillation (VF) was a prerequisite for the clinical trials that established the survival benefit of implantable cardioverter defibrillators (ICDs). However, for decades, a high incidence of unnecessary shocks limited patients' and physicians' acceptance of ICD therapy. Oversensing, misclassification of supraventricular tachycardia (SVT) as VT, and self-terminating VT accounted for the vast majority of unnecessary shocks. Medtronic ICDs utilize sensitive baseline settings with minimal blanking periods to ensure accurate sensing of VF, VT, and SVT electrograms. Programmable algorithms reject oversensing caused by far-field R waves, T waves, and non-physiologic signals caused by lead failure. A robust hierarchy of SVT-VT discriminators minimize misclassification of SVT as VT. These features, combined with evidence-based programming, have reduced the 1‑year inappropriate shock rate to 1.5 % for dual-/triple-chamber ICDs and to 2.5 % for single-chamber ICDs.

  6. Referring patients for consideration of device treatment of sudden cardiac death and heart failure: incorporating evidence-based therapies within the Canadian health care system.

    Science.gov (United States)

    Gillis, Anne M

    2005-05-01

    The growing use of the implantable cardioverter defibrillator (ICD) in Canada reflects the impact that primary and secondary prevention trials have had in demonstrating the superiority of the ICD over medical therapy in the prevention of sudden cardiac death in high-risk populations. Currently, there are significant regional disparities in ICD implantation in Canada. These disparities may reflect a lack of regional ICD implant and follow-up programs, and capping of funding for ICDs. In addition to increased funding for ICD systems, more resources are required to perform device implantations and follow patients over the long-term. Potentially eligible patients should be referred to an electrophysiologist for consideration of ICD therapy for the prevention of sudden cardiac death or to an electrophysiologist/ heart failure specialist for the consideration of combination cardiac resynchronization and ICD therapy for the management of refractory heart failure.

  7. Sexual Health for Patients with an Implantable Cardioverter Defibrillator

    Science.gov (United States)

    ... of the American Heart Association Cardiology Patient Page Sexual Health for Patients With an Implantable Cardioverter Defibrillator ... possible strategies for effective management. Barriers to Healthy Sexual Functioning in ICD Patients Despite limited research regarding ...

  8. Adding the implantable cardioverter-defibrillator to cardiac resynchronization therapy is associated with improved long-term survival in ischaemic, but not in non-ischaemic cardiomyopathy

    DEFF Research Database (Denmark)

    Witt, Christoffer Tobias; Kronborg, Mads Brix; Nohr, Ellen Aagaard;

    2015-01-01

    Hospital, Denmark from 2000 to 2010 were included. Baseline characteristics were retrieved from patient files and survival data were obtained from the Danish Civil Registration System. The primary outcome was all-cause mortality. The effect of ICD backup was estimated using Cox proportional hazards model...... to ischaemic cardiomyopathy (ICM) or non-ischaemic cardiomyopathy (NICM) treated with a CRT device with or without defibrillator backup. METHODS AND RESULTS: In this observational study, consecutive patients with an ejection fraction ≤35% and QRS width ≥120 ms receiving a CRT device at Aarhus University...

  9. Implantable cardioverter defibrillator therapy for primary prevention of sudden cardiac death in patients with heart failure%植入型心律转复除颤器在心力衰竭心脏性猝死一级预防中的作用初步观察

    Institute of Scientific and Technical Information of China (English)

    陈太波; 程康安; 高鹏; 刘博江; 范静波; 方全

    2010-01-01

    目的 总结我院应用植入型心律转复除颤器(ICD)进行心力衰竭心脏性猝死(SCD)一级预防的初步经验.方法 入选我院近3年因严重心力衰竭植入ICD进行SCD一级预防的患者,术后3个月进行ICD常规随访,以后每6个月随访1次.结果 入选患者22例,其中单腔ICD 15台,双腔ICD7台.22例患者随访时间3~28个月.记录ICD治疗事件21次,包括12次抗心动过速起搏(ATP)治疗和9次放电,只有1次ATP治疗患者具自觉症状.其中正确治疗(appropriate therapy)11次(52%)包括8次ATP治疗和3次放电,误治疗(inappropriate therapy)10次(48%).发生误治疗患者均为植入单腔ICD.结论 ICD可以安全有效地应用于心力衰竭SCD的一级预防,ICD误治疗事件是值得重视的临床问题,合理的ATP治疗可以提高患者的生活质量.%Objective To evaluate the effectiveness of implantable cardioverter defibrillator (ICD) therapy for primary prevention of sudden cardiac death (SCD) in patients with heart failure. Methods Twen-ty-two consecutive heart failure patients implanted with ICD for primary prevention of SCD in last 3 years were enrolled and followed up 3 months after implantation and every 6 months afterwards. Results Totally 22 cases were enrolled, including 15 with single-chamber ICD and 7 with dual-chamber ICD. Twenty-one ICD therapy events were documented during 3~28 months follow-up period, including 12 anti-tachycardia pacing (ATP) therapies and 9 shocks, and only one had symptoms. Eleven therapies (52%, 8 ATP therapies and 3 shocks) were classified as appropriate, and 10 (48%) as inappropriate. All inappropriate therapies were occurred in pa-tients implanted with single-chamber ICD. Conclusion In heart failure patients ICD for primary prevention of SCD was effective and appropriate. Relatively high incidence of inappropriate therapies remains a challenge. ATP therapy may improve the quality of life in ICD patients.

  10. Appropriate evaluation and treatment of heart failure patients after implantable cardioverter-defibrillator discharge: time to go beyond the initial shock.

    Science.gov (United States)

    Mishkin, Joseph D; Saxonhouse, Sherry J; Woo, Gregory W; Burkart, Thomas A; Miles, William M; Conti, Jamie B; Schofield, Richard S; Sears, Samuel F; Aranda, Juan M

    2009-11-24

    Multiple clinical trials support the use of implantable cardioverter-defibrillators (ICDs) for prevention of sudden cardiac death in patients with heart failure (HF). Unfortunately, several complicating issues have arisen from the universal use of ICDs in HF patients. An estimated 20% to 35% of HF patients who receive an ICD for primary prevention will experience an appropriate shock within 1 to 3 years of implant, and one-third of patients will experience an inappropriate shock. An ICD shock is associated with a 2- to 5-fold increase in mortality, with the most common cause being progressive HF. The median time from initial ICD shock to death ranges from 168 to 294 days depending on HF etiology and the appropriateness of the ICD therapy. Despite this prognosis, current guidelines do not provide a clear stepwise approach to managing these high-risk patients. An ICD shock increases HF event risk and should trigger a thorough evaluation to determine the etiology of the shock and guide subsequent therapeutic interventions. Several combinations of pharmacologic and device-based interventions such as adding amiodarone to baseline beta-blocker therapy, adjusting ICD sensitivity, and employing antitachycardia pacing may reduce future appropriate and inappropriate shocks. Aggressive HF surveillance and management is required after an ICD shock, as the risk of sudden cardiac death is transformed to an increased HF event risk.

  11. Dental management of a patient fitted with subcutaneous Implantable Cardioverter Defibrillator device and concomitant warfarin treatment

    OpenAIRE

    Altaf Hussain Shah; Hesham Saleh Khalil; Mohammed Zaheer Kola

    2015-01-01

    Automated Implantable Cardioverter Defibrillators (AICD), simply known as an Implantable Cardioverter Defibrillator (ICD), has been used in patients for more than 30 years. An Implantable Cardioverter Defibrillator (ICD) is a small battery-powered electrical impulse generator that is implanted in patients who are at a risk of sudden cardiac death due to ventricular fibrillation, ventricular tachycardia or any such related event. Typically, patients with these types of occurrences are on antic...

  12. Implantable cardioverter-defibrillators for treatment of sustained ventricular arrhythmias in patients with Chagas' heart disease: comparison with a control group treated with amiodarone alone.

    Science.gov (United States)

    Gali, Wagner L; Sarabanda, Alvaro V; Baggio, José M; Ferreira, Luís G; Gomes, Gustavo G; Marin-Neto, J Antônio; Junqueira, Luiz F

    2014-05-01

    Evidence is inconclusive concerning the benefit of implantable cardioverter-defibrillators (ICDs) for secondary prevention of mortality in patients with Chagas' heart disease (ChHD). The aim of this study was to compare the outcomes of ChHD patients with life-threatening ventricular arrhythmias (VAs), who were treated either with ICD implantation plus amiodarone or with amiodarone alone. The ICD group [76 patients; 48 men; age, 57 ± 11 years; left ventricular ejection fraction (LVEF), 39 ± 12%] and the historical control group treated with amiodarone alone (28 patients; 18 men; age, 54 ± 10 years; LVEF, 41 ± 10%) had comparable baseline characteristics, except for a higher use of beta-blockers in the ICD group (P < 0.0001). Amiodarone was also used in 90% of the ICD group. Therapy with ICD plus amiodarone resulted in a 72% reduced risk of all-cause mortality (P = 0.007) and a 95% reduced risk of sudden death (P = 0.006) compared with amiodarone-only therapy. The survival benefit of ICD was greatest in patients with LVEF < 40% (P = 0.01) and was not significant in those with LVEF ≥ 40% (P = 0.15). Appropriate ICD therapies occurred in 72% of patients and the rates of interventions were similar across patients with LVEF < 40% and ≥40%. Compared with amiodarone-only therapy, ICD implantation plus amiodarone reduced the risk of all-cause mortality and sudden death in ChHD patients with life-threatening VAs. Patients with LVEF < 40% derived significantly more survival benefit from ICD therapy. The majority of ICD-treated patients received appropriate therapies regardless of the LV systolic function.

  13. Comprehensive cardiac rehabilitation improves outcome for patients with implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Pedersen, Preben Ulrich; Zwisler, Ann-Dorthe

    2015-01-01

    Aims:The aim of this randomised clinical trial was to assess a comprehensive cardiac rehabilitation intervention including exercise training and psycho-education vs 'treatment as usual' in patients treated with an implantable cardioverter defibrillator (ICD).Methods:In this study 196 patients...... with first time ICD implantation (mean age 57.2 (standard deviation (SD)=13.2); 79% men) were randomised (1:1) to comprehensive cardiac rehabilitation vs 'treatment as usual'. Altogether 144 participants completed the 12 month follow-up. The intervention consisted of twelve weeks of exercise training and one...... year of psycho-educational follow-up focusing on modifiable factors associated with poor outcomes. Two primary outcomes, general health score (Short Form-36 (SF-36)) and peak oxygen uptake (VO2), were used. Post-hoc analyses included SF-36 and ICD therapy history.Results:Comprehensive cardiac...

  14. Psychological intervention following implantation of an implantable defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F

    2007-01-01

    The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current...... evidence on the efficacy of psychological intervention in ICD patients and recommendations for future research....

  15. Defibrillator Implantation in Patients with Nonischemic Systolic Heart Failure

    DEFF Research Database (Denmark)

    Køber, Lars; Thune, Jens J; Nielsen, Jens C

    2016-01-01

    BACKGROUND: The benefit of an implantable cardioverter-defibrillator (ICD) in patients with symptomatic systolic heart failure caused by coronary artery disease has been well documented. However, the evidence for a benefit of prophylactic ICDs in patients with systolic heart failure that is not d...... by Medtronic and others; DANISH ClinicalTrials.gov number, NCT00542945 .)....

  16. Arrhythmia Management in the Elderly-Implanted Cardioverter Defibrillators and Prevention of Sudden Death.

    Science.gov (United States)

    Manian, Usha; Gula, Lorne J

    2016-09-01

    We present an overview of arrhythmia management in elderly patients as it pertains to implantable cardioverter defibrillator (ICD) therapy and prevention of sudden death. Treatment of arrhythmia in elderly patients is fraught with challenges pertaining to goals of care and patient frailty. With an ever increasing amount of technology available, realistic expectations of therapy need to balance quality and quantity of life. The ICD is an important treatment option for selected patients at risk of ventricular arrhythmia and sudden cardiac death. However, the incidence of sudden death as a percentage of all-cause mortality decreases with age. Studies have reported that 20% of elderly patients might die within 1 year of an episode of life-threatening ventricular arrhythmia, but most because of nonarrhythmic causes. This illustrates the 'sudden cardiac death paradox,' with a great proportion of death in elderly patients, even those at risk for ventricular arrhythmias, attributable to medical conditions that cannot be addressed by an ICD. We discuss current practices in ICD therapy in elderly patients, existing evidence from registries and clinical trials, approaches to risk stratification, and important ethical considerations. Although the decision on whether ICD insertion is appropriate in the elderly population remains an area of uncertainty from an evidence-based and ethical perspective, we offer insight on potential clinical and research strategies for this growing population.

  17. Clinical efficacy and safety of an implantable cardioverter-defibrillator lead with a floating atrial sensing dipole

    DEFF Research Database (Denmark)

    Safak, Erdal; Schmitz, Dietmar; Konorza, Thomas;

    2013-01-01

    The concept of a single-lead implantable cardioverter-defibrillator (ICD), with a floating dipole, has been proven safe and functional.......The concept of a single-lead implantable cardioverter-defibrillator (ICD), with a floating dipole, has been proven safe and functional....

  18. Clinical experience with a novel subcutaneous implantable defibrillator system in a single center

    NARCIS (Netherlands)

    L. Dabiri Abkenari (Lara); D.A.M.J. Theuns (Dominic); S.D.A. Valk (Suzanne); Y. van Belle (Yves); N. de Groot (Natasja); D. Haitsma (David); A. Muskens-Heemskerk (Agnes); T. Szili-Torok (Tamas); L.J.L.M. Jordaens (Luc)

    2011-01-01

    textabstractBackground: Implantable cardioverter-defibrillators (ICDs) reduce mortality in both primary and secondary prevention, but are associated with substantial short- and long-term morbidity. A totally subcutaneous ICD (S-ICD) system has been developed. We report the initial clinical

  19. Defibrillation for Ventricular Fibrillation: A Shocking Update.

    Science.gov (United States)

    Nichol, Graham; Sayre, Michael R; Guerra, Federico; Poole, Jeanne

    2017-09-19

    Cardiac arrest is defined as the termination of cardiac activity associated with loss of consciousness, of spontaneous breathing, and of circulation. Sudden cardiac arrest and sudden cardiac death (SCD) are terms often used interchangeably. Most patients with out-of-hospital cardiac arrest have shown coronary artery disease or symptoms during the hour before the event. Cardiac arrest is potentially reversible by cardiopulmonary resuscitation, defibrillation, cardioversion, cardiac pacing, or treatments targeted at the underlying disease (e.g., acute coronary occlusion). We restrict SCD hereafter to cardiac arrest due to ventricular fibrillation, including rhythms shockable by an automatic external defibrillator (AED), implantable cardioverter-defibrillator (ICD), or wearable cardioverter-defibrillator (WCD). We summarize the state of the art related to defibrillation in treating SCD, including a brief history of the evolution of defibrillation, technical characteristics of modern AEDs, strategies to improve AED access and increase survival, ancillary treatments, and use of ICDs or WCDs. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Painless Implanted Cardioverter Defibrillator Therapy: Have We Taken It Seriously?%植入式心脏复律除颤器的无痛性治疗:我们重视了吗?

    Institute of Scientific and Technical Information of China (English)

    宿燕岗

    2011-01-01

    Shocking therapy of implanted cardioverter defibrillator (ICD) has been criticized for its causing myocardium damage and inducing electrical storm. Instead the anti-tachycardia pacing (ATP) function has been introduced as the main pain-free therapy of ICD, which could terminate about 3/4 ventricular tachycardia ( VT) events, without raising the risk of syncope or accelerated VT. The main concerns of ATP include differential identification of supraventricular tachycardia, re-confirmation of charging, settings of fast VT zone, strategies for optimization, and ATP while or before charging etc. , and the parameters should be adjusted individually during follow up. More concern should be paid to pain-free ICD therapy in clinical practice.%电击治疗可导致包括心肌损伤及诱发植入式心脏复律除颤器电风暴等弊端.植入式心脏复律除颤器的无痛性治疗主要是指其抗心动过速起搏功能.抗心动过速起搏能成功终止约3/4的室性心动过速事件,不增加晕厥或加速室性心动过速.无痛性治疗的主要策略包括室上性心动过速的鉴别程序、充电时的再确认、设定快速室性心动过速区、抗心动过速起搏策略优化、充电中和充电前抗心动过速起搏等.这些参数设置应个体化并在随访中进行调整.应重视植入式心脏复律除颤器无痛性治疗在临床上的应用.

  1. Lack of current implantable cardioverter defibrillator guidelines application for primary prevention of sudden cardiac death in Latin American patients with heart failure: a cross-sectional study.

    Science.gov (United States)

    Gonzalez-Zuelgaray, Jorge; Pellizon, Oscar; Muratore, Claudio A; Oropeza, Elsa Silva; Rabinovich, Rafael; Ramos, José Luis; Tentori, Maria Cristina; Reyes, Nicolás; Aguayo, Rubén; Marin, Jorge; Peterson, Brett J

    2013-02-01

    This cross-sectional study evaluated the application of accepted international implantable cardioverter defibrillator (ICD) guidelines for primary prevention of sudden cardiac death in patients with heart failure. The PLASMA (Probabilidad de Sufrir Muerte Arritmica) study was designed to characterize management of cardiac patients in Latin America. Twelve centres included 1958 consecutively admitted patients in cardiology units in 2008 and 2009. Discharged patients were evaluated for primary prevention, ICD indication and prescription by general cardiologists. Of 1711 discharged patients, 1525 (89%) had data available for evaluating indication status. Class I indications for ICD therapy were met for 153 (10%) patients based on collected data. Only 20 (13%, 95% confidence interval: 7.7-18.4%) patients with indication were prescribed an ICD. Patients prescribed an ICD were younger than patients who were not prescribed an ICD (62 vs. 68 years, P < 0.01). The reasons given by cardiologists for not prescribing an ICD for 133 patients with an indication were: indication criteria not met (75%), life expectancy <1 year (9.7%), rejection by the patient (5.2%), no medical coverage paying for the device (3.7%), psychiatric patient (2.2%), and other reasons (4.2%). In Latin America, international guidelines for primary prevention ICD implantation are not well followed. The main reason is that cardiologists believe that patients do not meet indication criteria, even though study data confirm that criteria are met. This poses a significant challenge and underlines the importance of continuous and improved medical education.

  2. Hospitalization rates and associated cost analysis of cardiac resynchronization therapy with an implantable defibrillator and quadripolar vs. bipolar left ventricular leads: a comparative effectiveness study.

    Science.gov (United States)

    Forleo, Giovanni B; Di Biase, Luigi; Bharmi, Rupinder; Dalal, Nirav; Panattoni, Germana; Pollastrelli, Annalisa; Tesauro, Manfredi; Santini, Luca; Natale, Andrea; Romeo, Francesco

    2015-01-01

    This study compares, from a prospective, observational, non-randomized registry, the post-implant hospitalization rates and associated healthcare resource utilization of cardiac resynchronization therapy-defibrillator (CRT-D) patients with quadripolar (QUAD) vs. bipolar (BIP) left ventricular (LV) leads. Between January 2009 and December 2012, 193 consecutive patients receiving de novo CRT-D implants with either a QUAD (n = 116) or a BIP (n = 77) LV lead were enrolled at implant and followed until July 2013 at a single-centre, university hospital. Post-implant hospitalizations related to heart failure (HF) or LV lead surgical revision and associated payer costs were identified using ICD-9-CM diagnosis and procedure codes. Italian national reimbursement rates were determined. Propensity scores were estimated using a logistic regression model based upon 11 pre-implant baseline characteristics and were used to derive a 1 : 1 matched cohort of QUAD (n = 77) and BIP (n = 77) patients. Hospitalization rates for the two groups were compared using negative binomial regression and associated payer costs were compared using non-parametric bootstrapping (×10 000) and one-sided hypothesis test. Hospitalization rates of the QUAD group [0.15/ patient (pt)-year] were lower than those of the BIP group (0.32/ pt-year); the incidence rate ratio was 0.46, P = 0.04. The hospitalization costs for the QUAD group (434 ± 128 €/pt-year) were lower than those for the BIP group (1136 ± 362 €/pt-year). The average difference was 718 €/pt-year, P = 0.016. In this comparative effectiveness assessment of well-matched groups of CRT-D patients with quadripolar and bipolar LV leads, QUAD patients experienced a lower rate of hospitalizations for HF and LV lead surgical revision, and a lower cost burden. This has important implications for LV pacing lead choice. © The Author 2014. Published by Oxford University Press on behalf of the European Society of Cardiology.

  3. The association between biventricular pacing and cardiac resynchronization therapy-defibrillator efficacy when compared with implantable cardioverter defibrillator on outcomes and reverse remodelling

    DEFF Research Database (Denmark)

    Ruwald, Anne-Christine; Kutyifa, Valentina; Ruwald, Martin H;

    2015-01-01

    : Using Kaplan-Meier plots, we estimated the threshold of BIV pacing percentage needed for CRT-D to be superior to ICD on the end-point of heart failure (HF) or death in 1219 left bundle branch block (LBBB) patients in the MADIT-CRT trial. Patients were censored at the time of crossover. In multivariable...

  4. Rationale, design, and baseline characteristics of the DANish randomized, controlled, multicenter study to assess the efficacy of Implantable cardioverter defibrillators in patients with non-ischemic Systolic Heart failure on mortality (DANISH)

    DEFF Research Database (Denmark)

    Thune, Jens Jakob; Pehrson, Steen; Nielsen, Jens Cosedis;

    2016-01-01

    BACKGROUND: The effect of an implantable cardioverter defibrillator (ICD) in patients with symptomatic systolic heart failure (HF) caused by coronary artery disease is well documented. However, the effect of primary prophylactic ICDs in patients with systolic HF not due to coronary artery disease...... by coronary artery disease have been randomized to receive an ICD or not, in addition to contemporary standard therapy. The primary outcome of the trial is time to all-cause death. Follow-up will continue until June 2016 with a median follow-up period of 5 years. Baseline characteristics show that enrolled...... (range, 21-84 years) at baseline, and 28% were women. CONCLUSION: DANISH will provide pertinent information about the effect on all-cause mortality of a primary prophylactic ICD in patients with symptomatic systolic HF not caused by coronary artery disease on contemporary standard therapy including CRT....

  5. Role of implantable cardioverter defibrillator in non-ischemic cardiomyopathy: a systematic review and meta-analysis of prospective randomized clinical trials.

    Science.gov (United States)

    Romero, Jorge; Chaudhary, Rahul; Garg, Jalaj; Lupercio, Florentino; Shah, Neeraj; Gupta, Rahul; Nazir, Talha; Bozorgnia, Babak; Natale, Andrea; Di Biase, Luigi

    2017-09-01

    A mortality benefit in patients with implantable cardioverter defibrillator (ICD) in ischemic cardiomyopathy is well established. However, the benefit of ICD implantation in non-ischemic cardiomyopathy (NICM) on total mortality remains uncertain. We performed a systematic review and meta-analysis of randomized controlled trials (RCT) evaluating the role of primary prevention ICD in NICM patients. We performed a systematic review on PubMed, The Cochrane Library, EMBASE, EBSCO, Web of Science, and CINAHL databases from the inception through February 2017 to identify RCT evaluating the role of ICD in NICM patients. Mantel-Haenszel risk ratio (RR) fixed effects model was used to summarize data across treatment arms. If heterogeneity (I (2)) ≥25, random effects model was used instead. We analyzed a total of 2573 patients from five RCTs comparing ICD with medical therapy in patients with NICM. The mean follow up for the trials was 48 ± 22 months. There was a significant reduction in (a) all-cause mortality (RR 0.84, 95% CI 0.71-0.99, p = 0.03) and (b) sudden cardiac death (RR 0.47, 95% CI 0.30-0.73, p < 0.001) in ICD group versus medical therapy. Our analysis demonstrates that the use of ICD for primary prevention is associated with a reduction in all-cause mortality and SCD in patients with NICM.

  6. Venous Obstruction Following Pacemaker or Implantable Cardioverter-Defibrillator Implantation, Mini Review

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Akbarzadeh

    2016-08-01

    Full Text Available Venous obstruction is relatively frequent following permanent pacemaker or implantable cardioverter-defibrillator (ICD implantation. However, most of them are asymptomatic. Although the exact risk factor for this complication is not known, number of leads, heart failure and infection may prone the patient to this complication. The goal standard for detection of vein stenosis is venography; however, ultrasound sonography has an acceptable accuracy. Anticoagulant therapy may be considered for symptomatic patients. For device upgrading, non-functional leads removal, venoplasty and rarely surgical treatment may be indicated.

  7. Ventricular Tachycardia with ICD Shocks: When to Medicate and When to Ablate.

    Science.gov (United States)

    AbdelWahab, Amir; Sapp, John

    2017-09-13

    Ventricular tachycardia occurrence in implantable cardioverter defibrillator (ICD) patients may result in shock delivery and is associated with increased morbidity and mortality. In addition, shocks may have deleterious mechanical and psychological effects. Prevention of ventricular tachycardia (VT) recurrence with the use of antiarrhythmic drugs or catheter ablation may be warranted. Antiarrhythmic drugs are limited by incomplete efficacy and an unfavorable adverse effect profile. Catheter ablation can be effective but acute complications and long-term VT recurrence risk necessitating repeat ablation should be recognized. A shared clinical decision process accounting for patients' cardiac status, comorbidities, and goals of care is often required. There are four published randomized trials of catheter ablation for sustained monomorphic VT (SMVT) in the setting of ischemic heart disease; there are no randomized studies for non-ischemic ventricular substrates. The most recent trial is the VANISH trial which randomly allocated patients with ICD, prior infarction, and SMVT despite first-line antiarrhythmic drug therapy to catheter ablation or more aggressive antiarrhythmic drug therapy. During 28 months of follow-up, catheter ablation resulted in a 28% relative risk reduction in the composite endpoint of death, VT storm, and appropriate ICD shock (p = 0.04). In a subgroup analysis, patients having VT despite amiodarone had better outcomes with ablation as compared to increasing amiodarone dose or adding mexiletine. There is evidence for the effectiveness of both catheter ablation and antiarrhythmic drug therapy for patients with myocardial infarction, an implantable defibrillator, and VT. If sotalol is ineffective in suppressing VT, either catheter ablation or initiation of amiodarone is a reasonable option. If VT occurs despite amiodarone therapy, there is evidence that catheter ablation is superior to administration of more aggressive antiarrhythmic drug therapy

  8. Sexual concerns and practices after ICD implantation

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Elleman-Jensen, Line; Zwisler, Ann-Dorthe;

    2013-01-01

    given about sexual activity, (b) the areas of patient concerns related to sexual function and the ICD, and (c) changes in sexual behavior.Methods:A randomized controlled trial including 196 patients (1:1) was designed, including 12 weeks of exercise training and 1 year of psycho-educational follow......Background:Studies show that patients with implantable cardioverter defibrillators (ICD) frequently experience sexual dysfunction. These experiences are often linked to exercise intolerance, side-effects of medication, and psychological problems.Objective:To describe (a) the level of information......-up focusing on modifiable factors associated with poor outcomes, including sexual functioning. The Sex After ICD Survey was administered 6 months after the randomization as part of the planned explorative outcomes. 141 patients responded.Results:The analyses showed that 37 of the 69 (55.2%) patients...

  9. Reuse of pacemakers, defibrillators and cardiac resynchronisation devices

    Science.gov (United States)

    Sakthivel, R; Satheesh, Santhosh; Ananthakrishna Pillai, Ajith; Sagnol, Pascal; Jouven, Xavier; Dodinot, Bernard; Balachander, Jayaraman

    2017-01-01

    Objective Access to pacemakers remains poor among many patients in low/middle-income countries. Reuse of explanted pacemakers is a possible solution, but is still not widespread because of concerns regarding outcomes, especially infection. Our objective was to study early outcomes with implants using reused devices and compare them with those with implants using new devices. Methods We studied all patients who underwent implantation of a new or reused pacemaker, cardiac resynchronisation therapy (CRT) device or implantable cardioverter defibrillator (ICD) in the last 5 years at a single institution. We analysed outcomes related to infection, device malfunction and device-related death within 6 months after initial implantation. Results During the study period, 887 patients underwent device implant, including 127 CRT devices or ICDs. Of these, 260 devices (29.3%) were reused and the others were new. At 6 months, there were three device-related infections in implants using a new device. There were no infections among patients receiving a reused device. There were no device malfunctions or device-related deaths in either group. Conclusions We found no difference in rate of infection or device malfunction among patients getting a reused device as compared with those with a new device. This study reinforces the safety of reusing devices for implant including CRT and ICDs. PMID:28176981

  10. In Rhythm : the Impact of an ICD on Quality of Life

    NARCIS (Netherlands)

    Kamphuis, Helena Christina Margien

    2005-01-01

    The main purpose of this study was to investigate quality of life in patients' who had survived a cardiac arrest and were treated with an implantable Cardioverter Defibrillator (ICD). Two groups were compared, those that had received an ICD with those that were treated otherwise. This thesis compris

  11. To implant or not to implant: Better risk stratification in ICD candidates

    NARCIS (Netherlands)

    Kraaier, K.

    2014-01-01

    This thesis is part of the ongoing search for better risk stratification in implantable cardioverter defibrillator (ICD) candidates. ICD implantation is the treatment of choice to prevent sudden cardiac death (SCD) in patients with life-threatening ventricular arrhythmias (secondary prevention) and

  12. Uniform pacemaker and ICD information system in the Netherlands

    NARCIS (Netherlands)

    Hooijschuur, CAM; Dijk, WA; van der Velde, W; Sanon, B; Ammeraal, C; Dassen, WRM; Spruijt, HJ; Murray, A

    2002-01-01

    In the Netherlands the Central Pacemaker Patient Registry (CPPR) collects information of pacemaker and ICD (Implantable Cardio Defibrillator) patients from all 109 Dutch hospitals. Many pacemaker clinics are using a computer to store their implant and follow-up data in a database. Because the device

  13. Influence of left ventricular function on survival and mode of death after implantable defibrillator therapy (Cleveland Clinic Foundation and Montefiore Medical Center experience).

    Science.gov (United States)

    Kim, S G; Maloney, J D; Pinski, S L; Choue, C W; Ferrick, K J; Roth, J A; Gross, J; Brodman, R; Furman, S; Fisher, J D

    1993-12-01

    To determine the influence of left ventricular (LV) function on survival and mode of death in patients with an implantable cardioverter-defibrillator (ICD), sudden death, surgical mortality, total arrhythmia-related death, total cardiac death and total death were retrospectively evaluated in 377 consecutive patients. The outcomes were also compared between patients with an LV ejection fraction > or = 30% (214 patients, group 1) and < 30% (148 patients, group 2). Surgical mortality was 3.9% (1.8% in group 1, 7% in group 2). During the follow-up of 25 +/- 20 months, actuarial survival rates of all patients at 3 years were 96% for sudden deaths, 81% for total cardiac deaths and 74% for total mortality. When the 2 groups were compared, survival rates of groups 1 and 2 at 3 years, respectively, were 99 and 90% for sudden death (p < 0.05), 97 and 84% for sudden death and surgical mortality (p < 0.01), 94 and 80% for the total arrhythmia-related death (p < 0.001), 88 and 68% for total cardiac death (p < 0.0001), and 81 and 62% for total mortality (p < 0.002). In group 2, 73% of total cardiac deaths within 1 year were causally related to the arrhythmia. Thus, in patients with an ICD, sudden death rates were very low. However, total cardiac death and total death rates were relatively higher. The outcomes of patients with an ICD were strongly influenced by the degree of LV dysfunction.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Clinical practice of defibrillator implantation after myocardial infarction: impact of implant time: results from the PreSCD II Registry†

    Science.gov (United States)

    Völler, Heinz; Kamke, Wolfram; Klein, Helmut U.; Block, Michael; Reibis, Rona; Treusch, Sven; Contzen, Klaus; Wegscheider, Karl

    2011-01-01

    Aims Current guidelines recommend implantable cardioverter-defibrillator (ICD) therapy for primary prevention of sudden cardiac death in patients with the reduced left ventricular function (LVEF ≤30%) not earlier than 40 days after myocardial infarction (MI). The aim of the prospective Prevention of Sudden Cardiac Death II (PreSCD II) registry was to investigate the clinical practice of ICD therapy in post-MI patients and to assess the impact on survival. Methods and results 10 612 consecutive patients (61 ± 12 years, 76% male) were enrolled 4 weeks or later after MI in 19 cardiac rehabilitation centres in Germany from December 2002 to May 2005. All patients with left ventricular ejection fraction (LVEF) ≤40% (n = 952) together with a randomly selected group of patients with preserved left ventricular function (n = 1106) were followed for 36 months. Cox proportional hazard models were used to correlate ICD implantation and survival with baseline characteristics. Of all patients studied, 75.9% were enrolled within 4–8 weeks, 10.7% more than 1 year after MI. Pre-specified Group 1 with an LVEF ≤30% consisted of 269 patients (2.5%), Group 2 with LVEF 31–40% of 727 patients (6.9%), and Group 3 with LVEF >40% of 1148 randomly selected patients from the cohort of 9616 patients with preserved LV function. After 36 months, only 142 patients (6.9%) had received an ICD; 82 (31.7%) of Group 1, 49 (7%) of Group 2, and 11 (1%) in Group 3. The ICD was implanted in 47% of all patients within 1 year after their index MI. Implantable cardioverter-defibrillator patients were predominantly characterized by low ejection fraction, but also by several other independent risk factors. Patients who received an ICD had an adjusted 44% lower mortality (hazard ratio 0.56, 95% confidence intervals 0.32–1.01; P = 0.053) than comparable patients without ICD therapy. All cause mortality of ICD recipients was significantly lower if the ICD was implanted later than 11 months after acute

  15. Long-term benefit of first-line peri-implantable cardioverter-defibrillator implant ventricular tachycardia-substrate ablation in secondary prevention patients.

    Science.gov (United States)

    Acosta, Juan; Cabanelas, Nuno; Penela, Diego; Fernández-Armenta, Juan; Andreu, David; Borràs, Roger; Korshunov, Viatcheslav; Cabrera, Mario; Vasanelli, Francesca; Arbelo, Elena; Guasch, Eduard; Martínez, Mikel; Tolosana, Jose M; Mont, Lluis; Berruezo, Antonio

    2017-06-01

    This study assessed the benefit of peri-implantable cardioverter-defibrillator implant ventricular tachycardia (VT)-substrate ablation in patients with structural heart disease (SHD). Patients with SHD and indication for secondary prevention ICD implant were prospectively included. Patients presenting with incessant and/or slow VT or frequent (≥2) VT episodes who underwent peri-ICD VT-substrate ablation (the scar dechannelling technique) were compared with those who received ICD alone and did not meet ablation criteria. The primary endpoint was any sustained VT/ICD therapy during follow-up. Of 206 patients included (43.2% non-ischaemic), 70 were assigned to ablation and 136 received ICD implant alone. During a mean follow-up of 45.6 ± 24.7 months, the primary endpoint was more frequent in the non-ablation group (47.1 vs. 22.9%; Pimplant VT-substrate ablation was associated with decreased VT recurrence and ICD shocks during long-term follow-up in patients with SHD and indication for secondary prevention ICD implant, especially in ischaemic patients. In patients with LVEF <35%, no benefit was observed in terms of VT recurrence-free survival, although VT burden during follow-up was lower in the ablation group.

  16. E-Health to Manage Distress in Patients With an Implantable Cardioverter-Defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Denollet, Johan; Cuijpers, Pim

    2014-01-01

    for anxiety (β = 0.35; p = .32), depression (β = -0.01; p = .98) or health-related quality of life (Mental Component Scale: β = 0.19; p = .86; Physical Component Scale: β = 0.58; p = .60) at 3 months, with effect sizes (Cohen d) being small (range, 0.06-0.13). There were also no significant group differences...... based on the problem-solving principles of cognitive behavioral therapy. RESULTS: Two hundred eighty-nine patients (85% response rate) were randomized. The prevalence of anxiety and depression ranged between 11% and 30% and 13% and 21%, respectively. No significant intervention effects were observed......UNLABELLED: The Web-based distress management program for patients with an implantable cardioverter-defibrillator (ICD; WEBCARE) was developed to mitigate distress and enhance health-related quality of life in ICD patients. This study investigated the treatment effectiveness at 3-month follow...

  17. Left ventricular ejection fraction normalization in cardiac resynchronization therapy and risk of ventricular arrhythmias and clinical outcomes

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Solomon, Scott D; Foster, Elyse

    2014-01-01

    within 2.2 years of follow-up. Risk of inappropriate ICD therapy is still present, and these patients could be considered for downgrade from CRT-defibrillator to CRT-pacemaker at the time of battery depletion if no VTAs have occurred. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique...

  18. Use of Guideline-Directed Medications for Heart Failure Before Cardioverter-Defibrillator Implantation.

    Science.gov (United States)

    Roth, Gregory A; Poole, Jeanne E; Zaha, Rebecca; Zhou, Weiping; Skinner, Jonathan; Morden, Nancy E

    2016-03-08

    Guideline-directed medical therapy (GDMT) for heart failure with reduced ejection fraction (HFrEF) is recommended before primary prevention implantable cardioverter-defibrillator (ICD) placement. Adherence to this recommendation and associated outcomes are unknown. This study examined the use of GDMT (≥1 prescription filled for both a renin-angiotensin inhibitor [RAI] and a heart failure-approved beta-blocker [HFBB]) within 90 days before primary prevention ICD placement in patients with HFrEF. Data from the National Cardiovascular Data Registry ICD Registry were merged with a 40% random sample of Medicare administrative data. Prescription fills for recipients of primary prevention ICD between 2007 and 2011 were examined, analyzing GDMT overall and for each U.S. hospital referral region. We identified characteristics associated with GDMT and the association with 1-year mortality. Among 19,733 patients with HFrEF and primary prevention ICD, 61.1% filled any GDMT before implantation. Across hospital referral regions, GDMT was applied in 51% to 71%. The strongest predictors of any GDMT included absence of chronic renal disease or nonsustained ventricular tachycardia, low-income prescription benefits subsidy, and less recent left ventricular ejection fraction evaluation. Patients receiving GDMT versus those without had a lower 1-year mortality rate after ICD implantation (11.1% vs. 16.2%), even after adjustment for comorbidities, left ventricular ejection fraction, and functional heart failure class. Rates of GDMT for HFrEF before primary prevention ICD implantation were low, and failure to achieve GDMT was associated with significantly decreased 1-year survival. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Association of Psychiatric History and Type D Personality with Symptoms of Anxiety, Depression, and Health Status Prior to ICD Implantation

    NARCIS (Netherlands)

    Starrenburg, Annemieke H.; Kraaier, Karin; Pedersen, Susanne S.; Hout, Moniek; Scholten, Marcoen; Palen, van der Job

    2013-01-01

    BACKGROUND: Personality factors and psychiatric history may help explain individual differences in risk of psychological morbidity and poor health outcomes in patients with an implantable cardioverter defibrillator (ICD). PURPOSE: We examined associations between previous anxiety and depressive diso

  20. Battery longevity from cardiac resynchronization therapy defibrillators: differences between manufacturers and discrepancies with published product performance reports.

    Science.gov (United States)

    Alam, Mian Bilal; Munir, Muhammad Bilal; Rattan, Rohit; Adelstein, Evan; Jain, Sandeep; Saba, Samir

    2017-03-01

    Cardiac resynchronization therapy (CRT) is an important treatment for heart failure that requires constant ventricular pacing, placing a high energy burden on CRT defibrillators (CRT-D). Longer battery life reduces the need for device changes and associated complications, thereby affecting patient outcomes and cost of care. We therefore investigated the time to battery depletion of CRT-D from different manufacturers and compared these results with manufacturers' published product performance reports (PPRs). All CRT-D recipients at our institution between January 2008 and December 2010 were included in this study cohort. The patients were followed up to the endpoint of battery depletion and were otherwise censored at the time of death, last follow-up, or device removal for any reason other than battery depletion. A total of 621 patients [173 Boston Scientific (BSC), 391 Medtronic (MDT), and 57 St. Jude Medical (SJM)] were followed up for a median of 3.7 (IQR 1.6-5.0) years, during which time 253 (41%) devices were replaced for battery depletion. Compared with MDT devices, battery depletion was 85 and 54% less likely to happen with BSC and SJM devices, respectively (P battery longevity by more than 20% 6 years after device implantation. Large differences in CRT-D battery longevity exist between manufacturers. Industry-published PPRs significantly overestimate device longevity. These data have important implications to patients, healthcare professionals, hospitals, and third-party payers.

  1. Electromagnetic Interference in Implantable Defibrillators in Single-Engine Fixed-Wing Aircraft.

    Science.gov (United States)

    de Rotte, Alexandra A J; van der Kemp, Peter; Mundy, Peter A; Rienks, Rienk; de Rotte, August A

    2017-01-01

    Little is known about the possible electromagnetic interferences (EMI) in the single-engine fixed-wing aircraft environment with implantable cardio-defibrillators (ICDs). Our hypothesis is that EMI in the cockpit of a single-engine fixed-wing aircraft does not result in erroneous detection of arrhythmias and the subsequent delivery of an inappropriate device therapy. ICD devices of four different manufacturers, incorporated in a thorax phantom, were transported in a Piper Dakota Aircraft with ICAO type designator P28B during several flights. The devices under test were programmed to the most sensitive settings for detection of electromagnetic signals from their environment. After the final flight the devices under test were interrogated with the dedicated programmers in order to analyze the number of tachycardias detected. Cumulative registration time of the devices under test was 11,392 min, with a mean of 2848 min per device. The registration from each one of the devices did not show any detectable "tachycardia" or subsequent inappropriate device therapy. This indicates that no external signals, which could be originating from electromagnetic fields from the aircraft's avionics, were detected by the devices under test. During transport in the cockpit of a single-engine fixed-wing aircraft, the tested ICDs did not show any signs of being affected by electromagnetic fields originating from the avionics of the aircraft. This current study indicates that EMI is not a potential safety issue for transportation of passengers with an ICD implanted in a single-engine fixed-wing aircraft.de Rotte AAJ, van der Kemp P, Mundy PA, Rienks R, de Rotte AA. Electromagnetic interference in implantable defibrillators in single-engine fixed-wing aircraft. Aerosp Med Hum Perform. 2017; 88(1):52-55.

  2. Infarct size and recurrence of ventricular arrhythmias after defibrillator implantation

    Energy Technology Data Exchange (ETDEWEB)

    Sutter, J. de; Tavernier, R.; Kazmierckzak, J.; Buyzere, M. de; Clement, D.L. [Department of Cardiology, University Hospital Gent, Gent (Belgium); Wiele, C. van de; Dierckx, R.A. [Department of Nuclear Medicine, University Hospital Gent (Belgium); Jordaens, L. [Thoraxcenter, University Hospital Rotterdam-Dijkzigt (Netherlands)

    2000-07-01

    Infarct size as determined by perfusion imaging is an independent predictor of mortality after implantable cardioverter defibrillator (ICD) implantation in patients with coronary artery disease (CAD) and life-threatening ventricular arrhythmias (VA). However, its value as a predictor of VA recurrence and hospitalisation after ICD implantation is unknown. Therefore, the objective of this study was to evaluate whether infarct size as determined by perfusion imaging can help to identify patients who are at high risk for recurrence of VA and hospitalisation after ICD implantation. We studied 56 patients with CAD and life-threatening VA. Before ICD implantation, all patients underwent a uniform study protocol including a thallium-201 stress-redistribution perfusion study. A defect score as a measurement of infarct size was calculated using a 17-segment 5-point scoring system. Study endpoints during follow-up were documented episodes of appropriate anti-tachycardia pacing and/or shocks for VA and cardiac hospitalisation for electrical storm (defined as three or more appropriate ICD interventions within 24 h), heart failure or angina. After a mean follow-up of 470{+-}308 days, 22 patients (39%) had recurrences of VA. In univariate analysis, predictors for recurrence were: (a) ventricular tachycardia (VT) as the initial presenting arrhythmia (86% vs 59% for patients without ICD therapy, P=0.04), (b) treatment with {beta}-blockers (36% vs 68%, P=0.03) and (c) a defect score (DS) {>=}20 (64% vs 32%, P=0.03). In multivariate analysis, VT as the presenting arrhythmia ({chi}2=5.51, P=0.02) and a DS {>=}20 ({chi}2=4.22, P=0.04) remained independent predictors. Cardiac hospitalisation was more frequent in patients with a DS {>=}20 (44% vs 13% for patients with DS <20, P=0.015) and this was particularly due to more frequent hospitalisations for electrical storm (24% vs 3% for patients with DS<20, P=0.037). The extent of scarring determined by perfusion imaging can separate

  3. [Remarks on the guideline recommendations for cardioverter-defibrillator implantation for primary prevention of sudden cardiac Death in patients with severe ventricular dysfunction. Consensus Document of the Italian Association of Hospital Cardiologists (ANMCO)/Italian Society of Cardiology (SIC)/Italian Association of Arrhythmology and Cardiac Pacing (AIAC)].

    Science.gov (United States)

    Berisso, Massimo Zoni; Bongiorni, Maria Grazia; Curnis, Antonio; Calvi, Valeria; Catanzariti, Domenico; Gaita, Fiorenzo; Gulizia, Michele Massimo; Inama, Giuseppe; Landolina, Maurizio E; La Rovere, Maria Teresa; Mantovan, Roberto; Mascioli, Giosuè; Occhetta, Eraldo; Padeletti, Luigi; Salerno-Uriarte, Jorge A; Santini, Massimo; Sassone, Biagio; Senni, Michele; Zecchin, Massimo

    2013-11-01

    The indications for implantable cardioverter-defibrillator (ICD) therapy for the prevention of sudden cardiac death in patients with severe left ventricular dysfunction have rapidly expanded over the last 10 years on the basis of the very satisfying results of the numerous randomized clinical trials that have provided the framework for guidelines. However, the analysis of clinical practice in the real world has highlighted some important criticisms in the complex process of selection-management of those patients candidates for ICD therapy: 1) approximately one fourth of all ICD implantations is not justified by clinical evidence, 2) approximately one half of patients with an indication for ICD therapy do not undergo implantation, 3) the benefits from ICD therapy do not apply uniformly to all patients, 4) the relationship between the lifesaving benefit and the potential for harm of ICD therapy is still scarcely known. The main reason for this clinical scenario can be ascribed to the guideline recommendations that are based only on few standard cut-off criteria and therefore too generic and insufficiently detailed. This does not help cardiologists in their decision-making process, and results in fear, uncertainty, and sometimes emotional choices. The aim of this consensus document is to discuss current guideline recommendations and to provide the Italian cardiologists with the most updated information to optimize the selection of patients with severe left ventricular dysfunction who should receive ICD therapy.

  4. 植入型心律转复除颤器在致心律失常性右心室心肌病患者中的应用%Implantable cardioverter defibrillator therapy in patients with arrhythmogenic right ventricular cardiomyopathy

    Institute of Scientific and Technical Information of China (English)

    孙奇; 陈柯萍; 陈若菡; 戴研; 华伟; 张澍

    2013-01-01

    Objective To evaluate the role of implantable cardioverter defibrillator(ICD) therapy in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC).Methods From Mar.2004 to Mar.2012,ARVC patients received ICD were enrolled in this study,and the clinical characteristics were collected.In the follow-up,we assessed the incidence,feature and ICD therapy in these patients.Results Eighteen patients were enrolled [12 men,6 women,mean age (46.4 ± 13.8) years].During the (46.6 ± 30.5) months followup period,ICD recorded 111 ventricular tachycardia (VT)/ventricular fibrillation (VF) episodes (1 VF,110 VT) in 6 patients.Among these,3 patients experienced 7 electrical storms(ES).Compare to patients without ICD therapy,C-reactive protein(CRP) level was higher in ICD therapy group.Among VT/VF episodes,12 episodes were terminated by shocks,99 episodes were terminated by anti-tachycardia pacing(ATP).Conclusions VT episodes were very common in ARVC patients,most of them could terminated by ATP.Repeated episodes of malignant arrhythmias in ARVC patients with ES were common.CRP level might be a significant predictor of appropriate ICD therapy in ARVC patients.%目的 总结阜外心血管病医院应用植入型心律转复除颤器(ICD)治疗致心律失常性右心室心肌病(ARVC)的经验.方法 入选我院2004年3月至2012年3月确诊并植入ICD的ARVC患者,收集临床资料,进行常规电话及门诊随诊.结果 共18例患者[男12例,女6例,平均年龄(46.4±13.8)岁]入选,平均随访(46.6±30.5)个月,有6例患者出现了111次室性心动过速(VT)/心室颤动(VF)事件,其中仅1次VF事件,其余均为VT事件,其中3例患者术后共出现了7次电风暴.ICD治疗组中的C反应蛋白(CRP)明显高于ICD未治疗组.111次VT/VF事件中,12次经电除颤终止心动过速,其余均通过抗心动过速起搏(ATP)终止了心动过速.结论 ARVC患者ICD植入后的VT/VF事件以VT为主,多数可经ATP终止;出现电风暴的ARVC患者

  5. 全自动远程家庭监测系统在植入心律转复除颤器患者中的应用%Home monitoring in patients with implantable cardioverter defibrillator or cardiac resynchronization therapy defibrillator

    Institute of Scientific and Technical Information of China (English)

    王凤梅; 李述峰; 王帆; 张烁

    2014-01-01

    目的 评价全自动远程家庭监测(HM)在植入心律转复除颤器(ICD)/心脏再同步治疗除颤器(CRT-D)患者中的应用.方法 随访23例植入了带有HM功能的ICD及CRT-D患者,分析HM所获得的日常信息和报警数据,观察其对系统相关事件、心律失常和心力衰竭(心衰)监测在内的临床相关事件的早期监测及临床干预的疗效.结果 对23例患者随访122~937(452.1±262.2)d,共接收报警信息1 991次,发现异常事件1 481次,其中96.4%是临床相关事件,1.5%为系统相关事件,无信息传输事件占2.1%.系统相关事件多为感知异常,其中发现左心室导线脱位1例.临床相关事件中心律失常报警事件占84.7%[室上性心律失常和心房颤动(房颤)事件较多],心衰报警事件占15.3%,以静息时心率升高及心脏再同步治疗心室起搏百分比降低为主.根据HM系统报警信息,电话联络患者65例次,优化参数11例次,指导调整药物治疗方案18例次,4例患者入院治疗.结论 对于植入ICD/CRT-D的患者,HM系统是一项必要的、安全可靠的远程监测方法,可以及时识别起搏系统相关异常、发现临床相关事件,可指导对患者进行早期临床干预,优化随访管理,提高患者生活质量.%Objective To evaluate the benefit of Home monitoring (HM) system in patients with implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillator(CRT-D).Methods Twentythree patients undergoing implantation of ICD or CRT-D with HM were enrolled,data automatically collected on a daily basis and alerts by HM were analyzed.Early detection and intervention effect of HM included arrhythmias or heart failure to clinical events and system related events.Results The mean follow-up duration was 122-937 (452.1±262.2) d,a total of 1 991 remote transmissions were received.Among these transmissions,1 481 abnormal events were reported,96.4% of events were clinical-related,and 1.5

  6. Validation of defibrillator lead performance registry data

    DEFF Research Database (Denmark)

    Kristensen, Anders Elgaard; Larsen, Jacob Moesgaard; Nielsen, Jens Cosedis

    2016-01-01

    AIMS: The validity of registry data on defibrillator lead performance is described only sparsely, despite its clinical importance. This study investigated the validity of defibrillator lead performance registry data in a nationwide and population-based registry. METHODS AND RESULTS: We identified...... all reported surgical interventions due to defibrillator lead events in the Danish Pacemaker and ICD Register (DPIR) from 2000 to 2013. Medical records of all patients (n = 753) were examined blinded for 5 predefined intervention types and 18 reasons for lead intervention. The overall level...... of agreement for the types of lead intervention had a positive predictive value (PPV) of 89.4% [95% confidence interval (CI): 87.0-91.5%] and an adjusted agreement (κ value) of 0.81 (95% CI: 0.77-0.85) representing an almost perfect match. Regarding the reasons for lead intervention, the overall PPV was 63...

  7. Current Indications for Implantable Cardioverter Defibrillators in Non-Ischemic Cardiomyopathies and Channelopathies.

    Science.gov (United States)

    González-Torrecilla, Esteban; Arenal, Angel; Atienza, Felipe; Datino, Tomás; Bravo, Loreto; Ruiz, Pablo; Ávila, Pablo; Fernández-Avilés, Francisco

    2015-01-01

    Current indications for implantable cardioverter defibrillators (ICDs) in patients with channelopathies and cardiomyopathies of non-ischemic origin are mainly based on non-randomized evidence. In patients with nonischemic dilated cardiomyopathy (NIDCM), there is a tendency towards a beneficial effect on total mortality of ICD therapy in patients with significant left ventricular (LV) dysfunction. Although an important reduction in sudden cardiac death (SCD) seems to be clearly demonstrated in these patients, a net beneficial effect on total mortality is unclear mostly in cases with good functional status. Risk stratification has been changing over the last two decades in patients with hypertrophic cardiomyopathy (HCM). Its risk profile has been delineated in parallel with the beneficial effect of ICD in high risk patients. Observational results based on "appropriate" ICD interventions do support its usefulness both in primary and secondary SCD prevention in these patients. Novel risk models quantify the rate of sudden cardiac death in these patients on individual basis. Less clear risk stratification is available for cases of arrhythmogenic right ventricular cardiomyopathy (ARVC) and in other uncommon familiar cardiomyopathies. Main features of risk stratification vary among the different channelopathies (long QT syndrome -LQTS-, Brugada syndrome, etc) with great debate on the management of asymptomatic patients. For most familiar cardiomyopathies, ICD therapy is the only accepted strategy in the prevention of SCD. So far, genetic testing has a limited role in risk evaluation and management of the individual patient. This review aims to summarize these criticisms and to refine the current indications of ICD implantation in patients with cardiomyopathies and major channelopathies.

  8. Protein Biomarkers Identify Patients Unlikely to Benefit from Primary Prevention ICDs: Findings from the PROSE-ICD Study

    Science.gov (United States)

    Cheng, Alan; Zhang, Yiyi; Blasco-Colmenares, Elena; Dalal, Darshan; Butcher, Barbara; Norgard, Sanaz; Eldadah, Zayd; Ellenbogen, Kenneth A.; Dickfeld, Timm; Spragg, David D.; Marine, Joseph E.; Guallar, Eliseo; Tomaselli, Gordon F.

    2015-01-01

    Background Primary prevention implantable cardioverter defibrillators (ICDs) reduce all-cause mortality but the benefits are heterogeneous. Current risk stratification based on left ventricular ejection fraction has limited discrimination power. We hypothesize that biomarkers for inflammation, neurohumoral activation and cardiac injury can predict appropriate shocks and all-cause mortality in patients with primary prevention ICDs. Methods and Results The Prospective Observational Study of Implantable Cardioverter Defibrillators (PROSe-ICD) enrolled 1,189 patients with systolic heart failure who underwent ICD implantation for primary prevention of sudden cardiac death. The primary endpoint was an ICD shock for adjudicated ventricular tachyarrhythmia. The secondary endpoint was all-cause mortality. After a median follow-up of 4.0 years, 137 subjects experienced an appropriate ICD shock and 343 participants died (incidence rates of 3.2 and 5.8 per 100 person-years, respectively). In multivariable adjusted models, higher interleukin-6 (IL-6) levels increased the risk of appropriate ICD shocks. In contrast, C-reactive protein, IL-6, tumor necrosis factor-α receptor II, pro-brain natriuretic peptide, and cardiac troponin T showed significant linear trends for increased risk of all-cause mortality across quartiles. A score combining these 5 biomarkers identified patients who were much more likely to die than to receive an appropriate shock from the ICD. Conclusions An increase in serum biomarkers of inflammation, neurohumoral activation and myocardial injury increased the risk for death but poorly predicted the likelihood of an ICD shock. These findings highlight the potential importance of serum-based biomarkers in identifying patients who are unlikely to benefit from primary prevention ICDs. PMID:25273351

  9. Making post-mortem implantable cardioverter defibrillator explantation safe

    OpenAIRE

    Räder, Sune B.E.W.; Zeijlemaker, Volkert; Pehrson, Steen; Svendsen, Jesper H

    2009-01-01

    Aims The aim of this study is to investigate whether protection with rubber or plastic gloves during post-mortem explantation of an implantable cardioverter defibrillator (ICD) offers enough protection for the explanting operator during a worst-case scenario (i.e. ICD shock). Methods and results We investigated the insulating properties of rubber and plastic gloves (double layer) within the first 60 min exposure (mimicking the maximum time of an explantation procedure) to saline (simulating t...

  10. Behavioral interventions in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Burg, Matthew M; Pedersen, Susanne S.

    2013-01-01

    The implantable cardioverter defibrillator (ICD) is the first-line treatment for primary and secondary prevention of sudden cardiac death. A subgroup of patients experience psychological distress postimplant, and no clear evidence base exists regarding how best to address patients' needs. The aim...... of this critical review is to provide an overview of behavioral interventions in ICD patients to date, and to delineate directions for future research using lessons learned from the ongoing RISTA and WEBCARE trials....

  11. Indications for implantable cardioverter-defibrillators based on evidence and judgment.

    Science.gov (United States)

    Myerburg, Robert J; Reddy, Vivek; Castellanos, Agustin

    2009-08-25

    Implantable cardioverter-defibrillators (ICDs) are generally reliable medical devices that have the potential to add quality years of life for appropriate candidates. Indications for ICDs have emerged from a series of randomized clinical trials, observational data from cohorts of high-risk patients with less common diseases, and expert opinion based on limited data in uncommon disorders. The randomized trials are limited by inadequate stratification designs that resulted from insufficient funding availability. The result was outcomes that led to uneven applications, based in part on post-implant experience of device utilization. In this document, we explore the basis for the features of the evidence available to support ICD use, the role of clinical judgment in circumstances in which data are limited or lacking, and the need for additional research to improve the specificity of indications. Directions for new research initiatives are considered. In addition, a general overview of a clinical research paradigm is presented, in which the research and health care delivery arms of the health care enterprise combine in research design and funding, as the latter bears the impact of the outcomes of the former. Impact estimates during the design of trials, considering reasonable contingencies for outcomes, are suggested as a means of justifying the size, scope, and appropriate costs of studies. If we who are involved in clinical research and health care delivery do not resolve this problem, for both ICDs and other new therapies that appear in the future, society will do it for us.

  12. Outcome of implantable cardioverter defibrillators in adults with congenital heart disease : a multi-centre study

    NARCIS (Netherlands)

    Yap, Sing-Chien; Roos-Hesselink, Jolien W.; Hoendermis, Elke S.; Budts, Werner; Vliegen, Hubert W.; Mulder, Barbara J. M.; van Dijk, Arie P. J.; Schalij, Martin J.; Drenthen, Willem

    2007-01-01

    Aims To investigate outcome and complications of implantable cardioverter defibrillators (ICDs) in adults with congenital heart disease (CHD) and to identify predictors of (in-) appropriate shocks. Methods and results Sixty-four CHD patients >= 18 years at first ICD implantation [63% tetralogy of Fa

  13. Emotional distress in partners of patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Van Den Broek, Krista C; Habibović, Mirela; Pedersen, Susanne S.

    2010-01-01

    Both patients with an implantable cardioverter defibrillator (ICD) and their partners face challenges when adapting to the ICD. Distress is a burden on its own for partners but may also affect well being and health of patients. This review provides a systematic overview of the literature on psych...

  14. Increased anxiety in partners of patients with a cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; VAN DEN Berg, Martha; Erdman, Ruud A M

    2009-01-01

    The partner of the implantable cardioverter-defibrillator (ICD) patient serves as an important source of support for the patient, which may be hampered if the partner experiences increased distress. We examined (1) potential differences in anxiety and depressive symptoms in ICD patients compared...

  15. Fuzzy logic-based diagnostic algorithm for implantable cardioverter defibrillators.

    Science.gov (United States)

    Bárdossy, András; Blinowska, Aleksandra; Kuzmicz, Wieslaw; Ollitrault, Jacky; Lewandowski, Michał; Przybylski, Andrzej; Jaworski, Zbigniew

    2014-02-01

    The paper presents a diagnostic algorithm for classifying cardiac tachyarrhythmias for implantable cardioverter defibrillators (ICDs). The main aim was to develop an algorithm that could reduce the rate of occurrence of inappropriate therapies, which are often observed in existing ICDs. To achieve low energy consumption, which is a critical factor for implantable medical devices, very low computational complexity of the algorithm was crucial. The study describes and validates such an algorithm and estimates its clinical value. The algorithm was based on the heart rate variability (HRV) analysis. The input data for our algorithm were: RR-interval (I), as extracted from raw intracardiac electrogram (EGM), and in addition two other features of HRV called here onset (ONS) and instability (INST). 6 diagnostic categories were considered: ventricular fibrillation (VF), ventricular tachycardia (VT), sinus tachycardia (ST), detection artifacts and irregularities (including extrasystoles) (DAI), atrial tachyarrhythmias (ATF) and no tachycardia (i.e. normal sinus rhythm) (NT). The initial set of fuzzy rules based on the distributions of I, ONS and INST in the 6 categories was optimized by means of a software tool for automatic rule assessment using simulated annealing. A training data set with 74 EGM recordings was used during optimization, and the algorithm was validated with a validation data set with 58 EGM recordings. Real life recordings stored in defibrillator memories were used. Additionally the algorithm was tested on 2 sets of recordings from the PhysioBank databases: MIT-BIH Arrhythmia Database and MIT-BIH Supraventricular Arrhythmia Database. A custom CMOS integrated circuit implementing the diagnostic algorithm was designed in order to estimate the power consumption. A dedicated Web site, which provides public online access to the algorithm, has been created and is available for testing it. The total number of events in our training and validation sets was 132. In

  16. Anxiety Predicts Mortality in ICD Patients

    DEFF Research Database (Denmark)

    Kikkenborg Berg, Selina; Caspar Thygesen, Lau; Hastrup Svendsen, Jesper

    2014-01-01

    BACKGROUND: Although highly effective in preventing arrhythmic death, patients receiving an implantable cardioverter defibrillator (ICD) may still experience psychological difficulties such as anxiety, depression, and reduced quality of life. The objectives of this study were to describe patient...... receiving ICD between January 1, 2011 and June 30, 2011 (n = 499). The following instruments were used: SF-36, Hospital Anxiety and Depression Scale, HeartQoL, EQ-5D, and the Multidimensional Fatigue Inventory. RESULTS: The response rate was 72%. Mean age was 65.5 years and 82% patients were males. Fifty...... of perceived health, quality of life, and fatigue; for example, physical health 39.8 versus 44.3 points, compared to secondary prevention indication. Anxiety, poor perceived health, fatigue, and low quality of life were all predictors of mortality, anxiety being the strongest with an adjusted odds ratio of 4...

  17. Interference of electronic apex locators with implantable cardioverter defibrillators

    NARCIS (Netherlands)

    Idzahi, K.; de Cock, C.C.; Shemesh, H.; Brand, H.S.

    2014-01-01

    Introduction The purpose of this in vitro study was to evaluate the potential electromagnetic interference of electronic apex locators (EALs) on implantable cardioverter defibrillators (ICDs). Methods Four different EALs were tested for their ability to interfere with the correct function of 3 diffe

  18. Risk of chronic anxiety in implantable defibrillator patients

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; den Broek, Krista C van; Theuns, Dominic A M J

    2011-01-01

    Little is known about the prevalence of chronic anxiety in patients with an implantable cardioverter defibrillator (ICD). In a multi-center, prospective study, we examined 1) the prevalence of chronic anxiety (i.e., patients anxious at implantation and 12 months), and 2) predictors of chronic...... anxiety....

  19. Phantom shocks in patients with implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Moons, Philip; Zwisler, Ann-Dorthe

    2013-01-01

    The aim of this trial was to assess a combined rehabilitation intervention including an exercise training component and a psycho-educational component in patients treated with implantable cardioverter defibrillator (ICD). The hypothesis was that the intervention would reduce the occurrence...

  20. Psychological effects of implantable cardioverter defibrillator shocks. A review of study methods

    OpenAIRE

    Manzoni, Gian Mauro; Castelnuovo, Gianluca; Compare, Angelo; Pagnini, Francesco; Essebag, Vidal; Proietti, Riccardo

    2015-01-01

    Background: The implantable cardioverter defibrillator (ICD) saves lives but clinical experience suggests that it may have detrimental effects on mental health. The ICD shock has been largely blamed as the main offender but empirical evidence is not consistent, perhaps because of methodological differences across studies. Objective: To appraise methodologies of studies that assessed the psychological effects of ICD shock and explore associations between methods and results. Data Sources...

  1. Psychological effects of implantable cardioverter defibrillator shocks. A review of study methods.

    OpenAIRE

    Gian Mauro eManzoni; Gianluca eCastelnuovo; Angelo eCompare; Francesco ePagnini; Vidal eEssebag; Riccardo eProietti

    2015-01-01

    BackgroundThe implantable cardioverter defibrillator (ICD) saves lives but clinical experience suggests that it may have detrimental effects on mental health. The ICD shock has been largely blamed as the main offender but empirical evidence is not consistent, perhaps because of methodological differences across studies. ObjectiveTo appraise methodologies of studies that assessed the psychological effects of ICD shock and explore associations between methods and results. Data Sources A compreh...

  2. Making post-mortem implantable cardioverter defibrillator explantation safe

    DEFF Research Database (Denmark)

    Räder, Sune B E W; Zeijlemaker, Volkert; Pehrson, Steen;

    2009-01-01

    AIMS: The aim of this study is to investigate whether protection with rubber or plastic gloves during post-mortem explantation of an implantable cardioverter defibrillator (ICD) offers enough protection for the explanting operator during a worst-case scenario (i.e. ICD shock). METHODS AND RESULTS...... that the resting voltage over the operating person would not exceed 50 V. CONCLUSION: The use of intact medical gloves made of latex, neoprene, or plastic eliminates the potential electrical risk during explantation of an ICD. Two gloves on each hand offer sufficient protection. We will recommend the use...

  3. [The Wearable Cardioverter Defibrillator (WCD) for the prevention of sudden cardiac death -- a single center experience].

    Science.gov (United States)

    Reek, S; Meltendorf, U; Geller, J C; Wollbrück, A; Grund, S; Klein, H U

    2002-12-01

    The Wearable Cardioverter Defibrillator (WCD) is an external defibrillator that automatically detects and treats ventricular tachyarrhythmias without the need for assistance from a bystander while at the same time allowing the patient to ambulate freely. The main components of the system are the defibrillator unit and a chest belt with electrodes for arrhythmia detection and therapy delivery. Between December 1998 and October 2001, 84 patients used the device at our institution. The majority of patients had a history of acute myocardial infarction or coronary artery bypass surgery with an increased risk for sudden cardiac death or were awaiting heart transplantation. During a mean follow-up of 116+/-90 days, 7 episodes of ventricular tachyarrhythmias were detected and terminated successfully by the WCD in 5 patients. In 9720 days, there was one inappropriate shock due to oversensing of electrical noise. Four patients died during follow-up; none of them had a cardiac arrest while wearing the device. Five patients were excluded because of irregularities in device use. An ICD was implanted in 24 patients at the end of the follow-up period. The WCD is effective in detecting and treating ventricular tachyarrhythmias in patients with an intermittently increased risk for sudden cardiac death. Further use of the system in larger patient populations is needed to confirm its safety and cost effectiveness.

  4. Increased incidence of life-threatening ventricular arrhythmias in implantable defibrillator patients after the World Trade Center attack.

    Science.gov (United States)

    Steinberg, Jonathan S; Arshad, Aysha; Kowalski, Marcin; Kukar, Atul; Suma, Valentin; Vloka, Margot; Ehlert, Frederick; Herweg, Bengt; Donnelly, Jacqueline; Philip, Julie; Reed, George; Rozanski, Alan

    2004-09-15

    This study was designed to evaluate whether the destruction of the World Trade Center (WTC) on September 11, 2001 (9/11), led to an increased frequency of ventricular arrhythmias among patients fitted with an implantable cardioverter-defibrillator (ICD). The WTC attack induced psychological distress. Because ICDs store all serious arrhythmias for months, the attack provided a unique opportunity to compare pre- and post-9/11 frequencies of potentially lethal arrhythmias among ICD patients. Two hundred consecutive ICD patients who presented for regularly scheduled follow-up to six affiliated clinics were recruited into this observational study. The electrograms stored in the ICDs for the three months before 9/11 and 13 months thereafter were scrutinized in a blinded manner (relative to date) for all ventricular tachyarrhythmias (tachycardia or fibrillation) triggering ICD therapy. The frequency of tachyarrhythmias increased significantly for the 30 days post-9/11 (p = 0.004) relative to all other months between May 2001 and October 2002. In the 30 days post-9/11, 16 patients (8%) demonstrated tachyarrhythmias, compared with only seven (3.5%) in the preceding 30 days, representing a 2.3-fold increase in risk (95% confidence interval 1.1 to 4.9; p = 0.03). The first arrhythmic event did not occur for three days following 9/11, with events accumulating in a progressive non-clustered pattern. Ventricular arrhythmias increased by more than twofold among ICD patients following the WTC attack. The delay in onset and the non-clustered pattern of these events differ sharply from effects following other disasters, suggesting that subacute stress may have served to promote this arrhythmogenesis.

  5. Cognitive-Behavioral Treatment of Posttraumatic Stress in Patients With Implantable Cardioverter Defibrillators: Results From a Randomized Controlled Trial.

    Science.gov (United States)

    Ford, Jessica; Rosman, Lindsey; Wuensch, Karl; Irvine, Jane; Sears, Samuel F

    2016-08-01

    Approximately 20% of patients with implantable cardioverter defibrillators (ICDs) suffer from posttraumatic stress disorder (PTSD) due to a history of cardiac arrest, device implantation, and ICD shock. There has been very little examination of treatment of PTSD symptoms in these patients. This study evaluated the effect of a specific cognitive-behavioral therapy (CBT) intervention for ICD patients with high levels of PTSD symptoms: a manualized program consisting of 8 telephone sessions with a trained counselor, a patient education book, and a stress management procedure on compact disc. Participants were 193 ICD patients, who were randomized to CBT or usual cardiac care (UCC) who completed self-report surveys at the time of recruitment and 6 and 12 months after initial measurement. Previous publication on the primary research evaluation questions reported that the CBT condition resulted in greater improvement on PTSD and depression symptoms than the UCC for the general population of ICD patients, but did not evaluate the effect on those with elevated symptoms of PTSD. The authors conducted secondary analyses of the effect of treatment on high and low PTSD symptom groups based on a cutoff for the Impact of Event Scale-Revised (Weiss & Marmar, 1997). Participants in the CBT group who had high symptoms experienced significantly greater symptom reduction from baseline to 12 months (d = 2.44, p = .021) than the UCC group (d = 1.12). Participants with low symptoms had small reductions regardless of group assignment (d = 0.16, p = .031). ICD-focused CBT was sufficient to produce a large, statistically significant reduction in PTSD symptoms in ICD patients with indications for treatment.

  6. Attrition and Adherence in a Web-Based Distress Management Program for Implantable Cardioverter Defibrillator Patients (WEBCARE): Randomized Controlled Trial

    DEFF Research Database (Denmark)

    Habibovic, M.; Cuijpers, P.; Alings, M.;

    2014-01-01

    Background: WEB-Based Distress Management Program for Implantable CARdioverter defibrillator Patients (WEBCARE) is a Web-based randomized controlled trial, designed to improve psychological well-being in patients with an implantable cardioverter defibrillator (ICD). As in other Web-based trials, ...

  7. Clinical Course After Cardioverter-Defibrillator Implantation: Chagasic Versus Ischemic Patients

    Science.gov (United States)

    Pereira, Francisca Tatiana Moreira; Rocha, Eduardo Arrais; Monteiro, Marcelo de Paula Martins; Lima, Neiberg de Alcantara; Rodrigues Sobrinho, Carlos Roberto Martins; Pires Neto, Roberto da Justa

    2016-01-01

    Background: The outcome of Chagas disease patients after receiving implantable cardioverter defibrillator (ICD) is still controversial. Objective: To compare clinical outcomes after ICD implantation in patients with chronic Chagas cardiomyopathy (CCC) and ischemic heart disease (IHD). Methods: Prospective study of a population of 153 patients receiving ICD (65 with CCC and 88 with IHD). The devices were implanted between 2003 and 2011. Survival rates and event-free survival were compared. Results: The groups were similar regarding sex, functional class and ejection fraction. Ischemic patients were, on average, 10 years older than CCC patients (p < 0.05). Patients with CCC had lower schooling and monthly income than IHD patients (p < 0.05). The number of appropriate therapies was 2.07 higher in CCC patients, who had a greater incidence of appropriate shock (p < 0.05). Annual mortality rate and electrical storm incidence were similar in both groups. There was no sudden death in CCC patients, and only one in IHD patients. Neither survival time (p = 0.720) nor event-free survival (p = 0.143) significantly differed between the groups. Conclusion: CCC doubles the risk of receiving appropriate therapies as compared to IHD, showing the greater complexity of arrhythmias in Chagas patients. PMID:27411097

  8. Cardiac sympathetic activity in chronic heart failure: cardiac (123)I-mIBG scintigraphy to improve patient selection for ICD implantation.

    Science.gov (United States)

    Verschure, D O; van Eck-Smit, B L F; Somsen, G A; Knol, R J J; Verberne, H J

    2016-12-01

    Heart failure is a life-threatening disease with a growing incidence in the Netherlands. This growing incidence is related to increased life expectancy, improvement of survival after myocardial infarction and better treatment options for heart failure. As a consequence, the costs related to heart failure care will increase. Despite huge improvements in treatment, the prognosis remains unfavourable with high one-year mortality rates. The introduction of implantable devices such as implantable cardioverter defibrillators (ICD) and cardiac resynchronisation therapy (CRT) has improved the overall survival of patients with chronic heart failure. However, after ICD implantation for primary prevention in heart failure a high percentage of patients never have appropriate ICD discharges. In addition 25-50 % of CRT patients have no therapeutic effect. Moreover, both ICDs and CRTs are associated with malfunction and complications (e. g. inappropriate shocks, infection). Last but not least is the relatively high cost of these devices. Therefore, it is essential, not only from a clinical but also from a socioeconomic point of view, to optimise the current selection criteria for ICD and CRT. This review focusses on the role of cardiac sympathetic hyperactivity in optimising ICD selection criteria. Cardiac sympathetic hyperactivity is related to fatal arrhythmias and can be non-invasively assessed with (123)I-meta-iodobenzylguanide ((123)I-mIBG) scintigraphy. We conclude that cardiac sympathetic activity assessed with (123)I-mIBG scintigraphy is a promising tool to better identify patients who will benefit from ICD implantation.

  9. [Implantation of a biventricular ICD in a patient with dextrocardia with situs inversus].

    Science.gov (United States)

    Vurgun, Veysel Kutay; Gerede, Menekşe; Altın, Ali Timuçin; Candemir, Başar; Akyürek, Ömer

    2015-01-01

    In order to reduce sudden cardiac death and heart failure symptoms, biventricular implantable cardioverter defibrillator (ICD) implantation is a treatment method commonly used in selected patients with cardiomyopathy. The frequency of dextrocardia in congenital heart defects is approximately 0.4/10000. In this group, the frequency of cardiomyopathy development is rare. In this case report we present a patient with dextrocardia undergoing implantation of biventricular ICD.

  10. Clinical benefit of cardiac resynchronization therapy with a defibrillator in patients with an ejection fraction > 35% estimated by cardiac magnetic resonance.

    Science.gov (United States)

    Fabregat-Andrés, Oscar; García-González, Pilar; Valle-Muñoz, Alfonso; Estornell-Erill, Jordi; Pérez-Boscá, Leandro; Palanca-Gil, Victor; Payá-Serrano, Rafael; Quesada-Dorador, Aurelio; Morell, Salvador; Ridocci-Soriano, Francisco

    2014-02-01

    Cardiac resynchronization therapy with a defibrillator prolongs survival and improves quality of life in advanced heart failure. Traditionally, patients with ejection fraction > 35 estimated by echocardiography have been excluded. We assessed the prognostic impact of this therapy in a group of patients with severely depressed systolic function as assessed by echocardiography but with an ejection fraction > 35% as assessed by cardiac magnetic resonance. We analyzed consecutive patients admitted for decompensated heart failure between 2004 and 2011. The patients were in functional class II-IV, with a QRS ≥ to 120 ms, ejection fraction ≤ 35% estimated by echocardiography, and a cardiac magnetic resonance study. We included all patients (n=103) who underwent device implantation for primary prevention. Ventricular arrhythmia, all-cause mortality and readmission for heart failure were considered major cardiac events. The patients were divided into 2 groups according to systolic function assessed by magnetic resonance. The 2 groups showed similar improvements in functional class and ejection fraction at 6 months. We found a nonsignificant trend toward a higher risk of all-cause mortality in patients with systolic function ≤ 35% at long-term follow-up. The presence of a pattern of necrosis identified patients with a worse prognosis for ventricular arrhythmias and mortality in both groups. We conclude that cardiac resynchronization therapy with a defibrillator leads to a similar clinical benefit in patients with an ejection fraction ≤ 35% or > 35% estimated by cardiac magnetic resonance. Analysis of the pattern of late gadolinium enhancement provides additional information on arrhythmic risk and long-term prognosis. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  11. Modulatory effects of cognitive behavior therapy on depression and anxiety in patients with implantable cardioverter defibrillator%认知行为疗法对心律转复除颤器植入患者抑郁焦虑症状的调节作用

    Institute of Scientific and Technical Information of China (English)

    祁述善; 方臻飞; 刘启明; 周胜华

    2005-01-01

    BACKGROUND: 60% of the patients receiving implantable cardioverter defibrillator(ICD) believe their quality of life has been improved. However,about 30% to 50% of the patients suffer from postoperative depression and anxiety; especially those patients receive electroconvulsive therapy (ECT).OBJECTIVE: To probe into the modulatory effects of cognitive behavior therapy(CBT) on depression and anxiety in patients with ICD.DESIGN: A retrospective case analysis based on ICD patients SETTING: Room of Cardiac Catheterization, Department of Cardiology, Xiangya Second Hospital PARTICIPANTS: The study was conducted in the Room of Cardiac Catheterization of the Department of Cardiology, Xiangya Second Hospital,Central South University from October 2000 to August 2001. Inclusive criteria: ICD patients that had ineffective medicine therapy for paroxysmal ventricular tachycardia and/or ventricular fibrillation complicated with cardiac syncope. Exclusive criteria: incoorperative patients or patients who unable to receive periodical follow up. A total of 6 patients were involved including 4 male and 2 female patients aged from 45 to 71 years old with an average age of (57.3 ± 2.4) years old. All of the patients received Micro Jewell Ⅱ 7223 ICD made by Medtronic Company. Diagnoses of basic disease:2 cases of coronary heart disease, 2 cases of right ventricular myocardial disease, 1 case of paroxysmal ventricular tachycardia due to unknown reason,and 1 case of Brugada syndrome.METHODS: "Morita therapy" technique was used. Patients were asked to transfer their spirit energies into feasible objectives of their real life, which would be helpful to the rapid improvement of their symptoms. symptom checklist-90(SCL-90) scale was used to evaluate the psychological symptoms before and after the therapy.MAIN OUTCOME MEASURES: Comparison of the scores gained in SCL-90 between before and after CBT.RESULTS: There were significant differences in the items of somatization,compulsion, sensitive

  12. Risk factors and the effect of cardiac resynchronization therapy on cardiac and non-cardiac mortality in MADIT-CRT

    DEFF Research Database (Denmark)

    Perkiomaki, Juha S; Ruwald, Anne-Christine; Kutyifa, Valentina;

    2015-01-01

    causes, 108 (63.9%) deemed cardiac, and 61 (36.1%) non-cardiac. In multivariate analysis, increased baseline creatinine was significantly associated with both cardiac and non-cardiac deaths [hazard ratio (HR) 2.97, P ...AIMS: To understand modes of death and factors associated with the risk for cardiac and non-cardiac deaths in patients with cardiac resynchronization therapy with implantable cardioverter-defibrillator (CRT-D) vs. implantable cardioverter-defibrillator (ICD) therapy, which may help clarify...... the action and limitations of cardiac resynchronization therapy (CRT) in relieving myocardial dysfunction. METHODS AND RESULTS: In Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT), during 4 years of follow-up, 169 (9.3%) of 1820 patients died of known...

  13. The use of automated external defibrillators and public access defibrillators in the mountains: official guidelines of the international commission for mountain emergency medicine ICAR-MEDCOM.

    Science.gov (United States)

    Elsensohn, Fidel; Agazzi, Giancelso; Syme, David; Swangard, Michael; Facchetti, Gianluca; Brugger, Hermann

    2006-01-01

    In this article we propose guidelines for rational use of automated external defibrillators and public access defibrillators in the mountains. In cases of ventricular fibrillation and pulseless ventricular tachycardia, early defibrillation is the most effective therapy. Easy access to mountainous areas permits visitation by persons with high risks for sudden cardiac death, and medical trials show the benefit of exercising in moderate altitude. The introduction of public access defibrillators in popular areas in the mountains may lead to a reduction of fatal outcome of cardiac arrest. Public access defibrillators should be placed with priority in popular ski areas, in busy mountain huts and restaurants, at mass-participation events, and in remote but often-visited locations that do not have medical coverage. Automated external defibrillators should be available to first-responder groups and mountain-rescue teams. It is important that people know how to perform cardiopulmonary resuscitation and how to use public access defibrillators and automated external defibrillators.

  14. Wrong detection of ventricular fibrillation in an implantable cardioverter defibrillator caused by the movement near the MRI scanner bore.

    Science.gov (United States)

    Mattei, Eugenio; Censi, Federica; Triventi, Michele; Mancini, Matteo; Napolitano, Antonio; Genovese, Elisabetta; Cannata, Vittorio; Falsaperla, Rosaria; Calcagnini, Giovanni

    2015-01-01

    The static magnetic field generated by MRI systems is highly non-homogenous and rapidly decreases when moving away from the bore of the scanner. Consequently, the movement around the MRI scanner is equivalent to an exposure to a time-varying magnetic field at very low frequency (few Hz). For patients with an implanted cardiac stimulators, such as an implantable cardioverter/defibrillator (ICD), the movements inside the MRI environment may thus induce voltages on the loop formed by the leads of the device, with the potential to affect the behavior of the stimulator. In particular, the ICD's detection algorithms may be affected by the induced voltage and may cause inappropriate sensing, arrhythmia detections, and eventually inappropriate ICD therapy.We performed in-vitro measurements on a saline-filled humanshaped phantom (male, 170 cm height), equipped with an MRconditional ICD able to transmit in real-time the detected cardiac activity (electrograms). A biventricular implant was reproduced and the ICD was programmed in standard operating conditions, but with the shock delivery disabled. The electrograms recorded in the atrial, left and right ventricle channels were monitored during rotational movements along the vertical axis, in close proximity of the bore. The phantom was also equipped with an accelerometer and a magnetic field probe to measure the angular velocity and the magnetic field variation during the experiment. Pacing inhibition, inappropriate detection of tachyarrhythmias and of ventricular fibrillation were observed. Pacing inhibition began at an angular velocity of about 7 rad/s, (dB/dt of about 2 T/s). Inappropriate detection of ventricular fibrillation occurred at about 8 rad/s (dB/dt of about 3 T/s). These findings highlight the need for a specific risk assessment of workers with MR-conditional ICDs, which takes into account also effects that are generally not considered relevant for patients, such as the movement around the scanner bore.

  15. Prophylactic implantable defibrillator in patients with arrhythmogenic right ventricular cardiomyopathy/dysplasia and no prior ventricular fibrillation or sustained ventricular tachycardia.

    LENUS (Irish Health Repository)

    Corrado, Domenico

    2010-09-21

    The role of implantable cardioverter-defibrillator (ICD) in patients with arrhythmogenic right ventricular cardiomyopathy\\/dysplasia and no prior ventricular fibrillation (VF) or sustained ventricular tachycardia is an unsolved issue.

  16. Performance of the subcutaneous implantable cardioverter-defibrillator in patients with a primary prevention indication with and without a reduced ejection fraction versus patients with a secondary prevention indication

    NARCIS (Netherlands)

    L. Boersma (Lucas); C.S. Barr (Craig); M.C. Burke (Martin); A. Leon (Angel); D.A.M.J. Theuns (Dominic); J.M. Herre (John M.); R. Weiss (Ram); Kremers, M.S. (Mark S.); P. Neuzil (Petr); M. Husby (Michael); N. Carter (Nathan); T. Stivland (Timothy); M.R. Gold (Michael)

    2017-01-01

    textabstractBackground: The subcutaneous implantable defibrillator (S-ICD) provides an alternative to the transvenous ICD for the prevention of sudden cardiac death, but has not been well studied in the most commonly treated transvenous ICD patient population, namely, primary prevention (PP) patient

  17. Performance of the subcutaneous implantable cardioverter-defibrillator in patients with a primary prevention indication with and without a reduced ejection fraction versus patients with a secondary prevention indication

    NARCIS (Netherlands)

    L. Boersma (Lucas); C.S. Barr (Craig); M.C. Burke (Martin); A. Leon (Angel); D.A.M.J. Theuns (Dominic); J.M. Herre (John M.); R. Weiss (Ram); Kremers, M.S. (Mark S.); P. Neuzil (Petr); M. Husby (Michael); N. Carter (Nathan); T. Stivland (Timothy); M.R. Gold (Michael)

    2017-01-01

    textabstractBackground: The subcutaneous implantable defibrillator (S-ICD) provides an alternative to the transvenous ICD for the prevention of sudden cardiac death, but has not been well studied in the most commonly treated transvenous ICD patient population, namely, primary prevention (PP)

  18. Type D personality is associated with increased anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator and their partners

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; van Domburg, Ron T; Theuns, Dominic A M J;

    2014-01-01

    We investigated the prevalence of anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator (ICD) and their partners, and the role of personality factors and social support as determinants of distress.......We investigated the prevalence of anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator (ICD) and their partners, and the role of personality factors and social support as determinants of distress....

  19. TASER conducted electrical weapons and implanted pacemakers and defibrillators.

    Science.gov (United States)

    Vanga, Subba R; Bommana, Sudharani; Kroll, Mark W; Swerdlow, Charles; Lakkireddy, Dhanunjaya

    2009-01-01

    Conducted electrical weapons (CEW) have generated controversy in recent years regarding their effect on heart rhythm and on their suspected interaction with implanted devices such as the pacemakers and ICDs (implantable cardioverter defibrillators). We review the current evidence available on device interactions and pre-sent a new case series of 6 patients. We used the available case reports and animal studies on TASER or CEW related publications in PubMed. Oversensing of TASER CEW discharges may cause noise reversion pacing in pacemakers and inappropriate detection of VF in ICDs. The nominal 5-second discharge is sufficiently short that neither clinically significant inhibition of bradycardia pacing nor inappropriate ICD shocks have been reported. Current evidence indicates that CEW discharges do not have adverse effects on pacemakers and ICDs.

  20. Spinal cord stimulation for refractory angina in patients implanted with cardioverter defibrillators: five case reports

    DEFF Research Database (Denmark)

    Enggaard, Thomas P; Andersen, Claus; Scherer, Christian

    2010-01-01

    successful long-term treatment with SCS in five patients implanted with cardioverter defibrillators. The combined treatments with ICD and thoracic epidural electrical stimulation were used in five patients with refractory angina pectoris. During the procedure of the implantation, testing with the maximal...... tolerable level of stimulation was carried out to exclude inference with the ICD. The following treatment with SCS has in all cases been successful, with significant pain relief and improved quality of life. There were no incidences of inappropriate defibrillator shocks. Spinal cord stimulation...

  1. The economic impact of battery longevity in implantable cardioverter-defibrillators for cardiac resynchronization therapy: the hospital and healthcare system perspectives.

    Science.gov (United States)

    Landolina, Maurizio; Morani, Giovanni; Curnis, Antonio; Vado, Antonello; D'Onofrio, Antonio; Bianchi, Valter; Stabile, Giuseppe; Crosato, Martino; Petracci, Barbara; Ceriotti, Carlo; Bontempi, Luca; Morosato, Martina; Ballari, Gian Paolo; Gasparini, Maurizio

    2017-08-01

    Patients receiving cardiac resynchronization therapy defibrillators (CRT-Ds) are likely to undergo one or more device replacements, mainly for battery depletion. We assessed the economic impact of battery depletion on the overall cost of CRT-D treatment from the perspectives of the healthcare system and the hospital. We also compared devices of different generations and from different manufacturers in terms of therapy cost. We analysed data on 1792 CRT-Ds implanted in 1399 patients in 9 Italian centres. We calculated the replacement probability and the total therapy cost over 6 years, stratified by device generation and manufacturer. Public tariffs from diagnosis-related groups were used together with device prices and hospitalization costs. Generators were from 3 manufacturers: Boston Scientific (667, 37%), Medtronic (973, 54%), and St Jude Medical (152, 9%). The replacement probability at 6 years was 83 and 68% for earlier- and recent-generation devices, respectively. The need for replacement increased total therapy costs by more than 50% over the initial implantation cost for hospitals and by more than 30% for healthcare system. The improved longevity of recent-generation CRT-Ds reduced the therapy cost by ∼6% in both perspectives. Among recent-generation CRT-Ds, the replacement probability of devices from different manufacturers ranged from 12 to 70%. Consequently, the maximum difference in therapy cost between manufacturers was 40% for hospitals and 19% for the healthcare system. Differences in CRT-D longevity strongly affect the overall therapy cost. While the use of recent-generation devices has reduced the cost, significant differences exist among currently available systems.

  2. Clinical and Serum-Based Markers Are Associated with Death within 1 year of de novo Implant in Primary Prevention ICD Recipients

    Science.gov (United States)

    Zhang, Yiyi; Guallar, Eliseo; Blasco-Colmenares, Elena; Dalal, Darshan; Butcher, Barbara; Norgard, Sanaz; Tjong, Fleur V. Y.; Eldadah, Zayd; Dickfeld, Timm; Ellenbogen, Kenneth A.; Marine, Joseph E.; Tomaselli, Gordon F.; Cheng, Alan

    2014-01-01

    Background Implantable cardioverter defibrillator (ICD) implantation is contraindicated in those with <1 year life expectancy. Objective To develop a risk prediction score for 1-year mortality in patients with primary prevention ICDs and to determine the incremental improvement in discrimination when incorporating serum-based biomarkers to traditional clinical variables. Methods We analyzed data from the PROSE-ICD study, a large prospective observational study of patients undergoing primary prevention ICD implantation who were extensively phenotyped for clinical and serum markers. We identified variables predicting 1-year mortality and synthesized them into a comprehensive risk scoring construct using backward selection. Results Among 1,189 patients deemed by their treating physicians as having reasonable 1 year life expectancy, 62 patients died within 1 year of ICD implantation. The risk score, comprised of 6 clinical factors (age ≥75 years, New York Heart Association class III/IV, atrial fibrillation, eGFR <30mL/min/1.73m2, diabetes, and use of diuretics), had good discrimination (AUC=0.77) for 1-year mortality. Addition of 3 biomarkers (TNF-αRII, pro-BNP, and cTnT) further improved model discrimination to 0.82. Patients with 0-1, 2-3, 4-6, or 7-9 risk factors had 1-year mortality rates of 0.8%, 2.7%, 16.1% and 46.2%, respectively. Conclusions Individuals with more co-morbidities and elevations of specific serum biomarkers were at increased risk for all-cause mortality despite being deemed as having reasonable 1 year life expectancy. A simple risk score comprised of readily available clinical data and serum biomarkers may better identify patients at high risk of early mortality and improve patient selection and counseling for primary prevention ICD therapy. PMID:25446153

  3. Defibrillation in children

    Directory of Open Access Journals (Sweden)

    Haskell Sarah

    2010-01-01

    Full Text Available Defibrillation is the only effective treatment for ventricular fibrillation (VF. Optimal methods for defibrillation in children are derived and extrapolated from adult data. VF occurs as the initial rhythm in 8-20% of pediatric cardiac arrests. This has fostered a new interest in determining the optimal technique for pediatric defibrillation. This review will provide a brief background of the history of defibrillation and a review of the current literature on pediatric defibrillation. The literature search was performed through PubMed, using the MeSH headings of cardiopulmonary resuscitation, defibrillation and electric countershock. The authors′ personal bibliographic files were also searched. Only published articles were chosen. The recommended energy dose has been 2 J/kg for 30 years, but recent reports may indicate that higher dosages may be more effective and safe. In 2005, the European Resuscitation Council recommended 4 J/kg as the initial dose, without escalation for subsequent shocks. Automated external defibrillators are increasingly used for pediatric cardiac arrest, and available reports indicate high success rates. Additional research on pediatric defibrillation is critical in order to be able to provide an equivalent standard of care for children in cardiac arrest and improve outcomes.

  4. Implantable cardioverter-defibrillator infection caused by Tsukamurella.

    Science.gov (United States)

    Almehmi, Ammar; Pfister, Alfred K; McCowan, Ronald; Matulis, Susie

    2004-01-01

    Human infections with Tsukamurella are very rare with only 13 reported cases in the literature. Certain conditions, such as immunosuppression, an indwelling foreign body, and postoperative wounds predispose humans to Tsukamurella infections. The rarity of Tsukamurella infection in humans makes its diagnosis and treatment very difficult. This article describes the first case of implantable cardioverter-defibrillator (ICD) infection related to Tsukamurella in the literature.

  5. The occupational routine of patients implanted with cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Juliana Mannini

    2015-03-01

    Full Text Available Implantable cardioverter-defibrillators (ICD have become a reference as to the standard of care for patients with potentially lethal ventricular arrhythmias. The ICD treats the symptoms of the disease with no impact on its cause; however, the electrical discharge originating from the operating mechanism of this device has been the source of many studies addressing the quality of life of this population. The specific literature points to limitations of patients implanted with cardioverter-defibrillators regarding activities such as working and driving, but little has been discussed whether other areas of occupational performance are also limited. The purpose of this prospective exploratory research, which uses a case study design of quantitative nature, is to know the routine of patients implanted with cardioverter-defibrillator. Fifteen subjects with ICD participated in the study; they were outpatients in the arrhythmia sector of the ‘Clementino Fraga Filho’ University Hospital - HUCFF. The instruments for data collection included an initial interview, SF36 inventory, Role Checklist, and an open question. The results showed interference in the routine occupational performance and occupational roles evaluated, as well as in the fields of mental health and vitality, with greater focus on influences arising from the pathology than the mechanism of the device.

  6. Shoulder joint dislocation as an unusual complication of defibrillation threshold testing following subcutaneous implantable cardioverter-defibrillator implantation.

    Science.gov (United States)

    Noheria, Amit; Cha, Yong-Mei; Asirvatham, Samuel J; Friedman, Paul A

    2014-01-01

    A 53-year-old man underwent implantation of a totally subcutaneous ICD (S-ICD; Boston Scientific). He was positioned supine, with the left arm abducted, externally rotated (i.e. palm up) and strapped to the arm extender. The generator was placed in the left mid-axillary line along the 5th-6th intercostal spaces and the defibrillation coil was tunneled anterior to the sternum. Defibrillation threshold (DFT) testing with 65 Jcaused a forceful pectoralis twitch. The patient woke up with a painful anteriorly dislocated left shoulder. Glenohumeral dislocation due to DFT testing has not been previously reported. It is likely that this complication is specific to the S-ICD implantation, and is related to positioning with the arm abducted, externally rotated, and immobilized, and use of greater defibrillation energy with current pathway through the bulk of the pectoralis muscle.Precautions may include extending the arm palm down, strapping the arm loosely, and adduction of the arm for DFT testing.

  7. Pre-clinical detection of amiodarone-induced acute fibrosing alveolitis by intra-thoracic impedance monitor of an implantable cardioverter-defibrillator.

    Science.gov (United States)

    Hsieh, Yu-Cheng; Huang, Jin-Long; Chin, Chun-Shih; Lin, Tung-Chao; Liao, Ying-Chieh; Ting, Chih-Tai; Wu, Tsu-Juey

    2011-01-01

    A 66-year-old male received an implant of a dual-chamber implantable cardioverter-defibrillator (ICD) and was prescribed amiodarone (400 mg/day). The intra-thoracic impedance monitor in the ICD antecedently detected amiodarone-induced acute fibrosing alveolitis >3 months prior to clinical symptoms.

  8. Antitachycardia pacing programming in implantable cardioverter defibrillator: A systematic review.

    Science.gov (United States)

    De Maria, Elia; Giacopelli, Daniele; Borghi, Ambra; Modonesi, Letizia; Cappelli, Stefano

    2017-05-26

    Implantable cardioverter defibrillator (ICD) programming involves several parameters. In recent years antitachycardia pacing (ATP) has gained an increasing importance in the treatment of ventricular arrhythmias, whether slow or fast. It reduces the number of unnecessary and inappropriate shocks and improves both patient's quality of life and device longevity. There is no clear indication regarding the type of ATP to be used, except for the treatment of fast ventricular tachycardias (188 bpm-250 bpm) where it has been shown a greater efficacy and safety of burst compared to ramp; 8 impulses in each sequence of ATP appears to be the best programming option in this setting. Beyond ATP use, excellent clinical results were obtained with programming standardization following these principles: extended detection time in ventricular fibrillation (VF) zone; supraventricular discrimination criteria up to 200 bpm; first shock in VF zone at the maximum energy in order to reduce the risk of multiple shocks. The MADIT-RIT trial and some observational registries have also recently demonstrated that programming with a widespread use of ATP, higher cut-off rates or delayed intervention reduces the number of inappropriate and unnecessary therapies and improves the survival of patients during mid-term follow-up.

  9. Pacemakers, defibrillators, and direct current cardioversion.

    Science.gov (United States)

    Sgarbossa, E B; Black, I W; Maloney, J D

    1993-01-01

    Technology for pacemakers and automatic implantable defibrillators continues to evolve. Emphasis is placed not only on preventing cardiac death, but also on improving symptoms and quality of life. The basic antibradycardia function of pacemakers is complemented by highly sophisticated rate-responsive capabilities. The search for the perfect physiologic sensor has not ended; potential limitations of the systems currently available are considered in this review. Reports on outcome with pacing in different populations are also discussed. There have been two important advances in automatic implantable defibrillators. One is the introduction of the third generation defibrillator in clinical investigation. A tiered therapy (including antitachycardia pacing, cardioversion, and defibrillation) can now be programmed in the same device, with the protection of back-up antibradycardia pacing. The other remarkable innovation is the expanding use of nonthoracotomy techniques for implantable cardioverter-defibrillator placement. This approach permits the avoidance of a subcutaneous patch electrode in some cases, the system being entirely transvenous. Finally, recent insights on external cardioversion for atrial arrhythmias are briefly reviewed.

  10. The NO Regular Defibrillation testing In Cardioverter Defibrillator Implantation (NORDIC ICD) trial

    DEFF Research Database (Denmark)

    Bänsch, Dietmar; Bonnemeier, Hendrik; Brandt, Johan

    2015-01-01

    was standardized across all participating centres. After inducing a fast ventricular tachycardia (VT) with a heart rate ≥240 b.p.m. or ventricular fibrillation (VF) with a low-energy T-wave shock, DF was attempted with an initial 15 J shock. If the shock reversed the VT or VF, DF testing was considered successful...

  11. Single lead catheter of implantable cardioverter-defibrillator with floating atrial sensing dipole implanted via persistent left superior vena cava.

    Science.gov (United States)

    Malagù, Michele; Toselli, Tiziano; Bertini, Matteo

    2016-04-26

    Persistent left superior vena cava (LSVC) is a congenital anomaly with 0.3%-1% prevalence in the general population. It is usually asymptomatic but in case of transvenous lead positioning, i.e., for pacemaker or implantable cardioverter defibrillator (ICD), may be a cause for significant complications or unsuccessful implantation. Single lead ICD with atrial sensing dipole (ICD DX) is a safe and functional technology in patients without congenital abnormalities. We provide a review of the literature and a case report of successful implantation of an ICD DX in a patient with LSVC and its efficacy in treating ventricular arrhythmias.

  12. Psychometric analysis of the Patient Health Questionnaire in Danish patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Mathiasen, Kim; Christensen, Karl Bang

    2016-01-01

    OBJECTIVE: To assess the psychometric properties of the Patient Health Questionnaire (PHQ-9), a measure of depressive symptoms, in a large Danish national cohort of patients with heart disease, implanted with an implantable cardioverter defibrillator (ICD), using item response theory. METHODS...

  13. Effects of an alert system on implantable cardioverter defibrillator-related anxiety

    DEFF Research Database (Denmark)

    Duru, Firat; Dorian, Paul; Favale, Stefano

    2010-01-01

    Implantable cardioverter defibrillators (ICD) can prevent sudden cardiac death by delivering high-energy shocks in patients at risk of life-threatening ventricular tachyarrhythmias. Patients may be anxious about receiving inappropriate shocks in case of device or lead system malfunction, or about...

  14. Monitoring device acceptance in implantable cardioverter defibrillator patients using the Florida Patient Acceptance Survey

    DEFF Research Database (Denmark)

    Versteeg, Henneke; Starrenburg, Annemieke; Denollet, Johan

    2012-01-01

    Patient device acceptance might be essential in identifying patients at risk for adverse patient-reported outcomes following implantation of an implantable cardioverter defibrillator (ICD). We examined the validity and reliability of the Florida Patient Acceptance Scale (FPAS) and identified corr...

  15. Gender disparities in anxiety and quality of life in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; van den Broek, Krista C; Theuns, Dominic A M J

    2011-01-01

    A paucity of studies in implantable cardioverter-defibrillator (ICD) patients has examined gender disparities in patient-reported outcomes, such as anxiety and quality of life (QoL). We investigated (i) gender disparities in anxiety and QoL and (ii) the magnitude of the effect of gender vs. New...

  16. Experiences of patients with implantable cardioverter defibrillator in Turkey: A qualitative study

    Directory of Open Access Journals (Sweden)

    Özgür Aslan

    2012-01-01

    Full Text Available Background. There has been an increase in the number of patients with implantable cardioverter defibrillator (ICD. It isimportant to understand ICD patients’ experiences with it.Aim. The aim of this study was to describe experiences of patients with implantable cardioverter defibrillator (ICD.Methodology. A qualitative approach was used. Focus group interviews were used to obtain data from 19 patients whowere implanted cardioverter defibrillator at two centers in Izmir, Turkey. The patients were assigned into four groups. Thedata was analyzed using qualitative content analysis.Results. The analysis revealed six main themes: activities of daily living, social life, familial relationships, emotionalchanges, implantable cardioverter defibrillator shocks and experiences with receiving information and counselling fromhealth care providers.Conclusions. It can be concluded that patients with ICD experience physical and psychological problems and are not offeredthe education they need. To reduce the fears of the patients and their families and to prepare them for possible life stylechanges, comprehensive training programs that start in the pre-implantation period and continue into the post-implantationperiod should be organized.

  17. Undertreatment of anxiety and depression in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Theuns, Dominic A M J

    2012-01-01

    Twenty-five to 33% of patients with an implantable cardioverter-defibrillator (ICD) experience anxiety and depression, but it is not known whether their symptoms are adequately treated. We investigated (a) whether patients with clinically relevant symptoms of distress received appropriate treatment...

  18. SUDDEN CARDIAC DEATH AND THE USE OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS IN PEDIATRIC-PATIENTS

    NARCIS (Netherlands)

    SILKA, MJ; KRON, J; DUNNIGAN, A; DICK, M; BINKBOELKENS, M; ERICKSON, CC; JEDEIKIN, R; WETZEL, GT; VANHARE, GF; CAMPBELL, R; WALSH, E; SAUL, JP; SCHAFFER, MS; KARPAWICH, P; VOGEL, RL; BENSON, DW; DEAL, B; SCAGLIOTTI, D; STERBA, R; HORDOF, AJ; KRONGRAD, E; KANTER, RJ; EPSTEIN, M; COHEN, M; BEDER, S; HAMILTON, R; FOURNIER, A; HUBBARD, J; CHRISTIANSEN, JL; JENNINGS, J; VILLAFANE, J; PORTER, CBJ; CASE, C; GILLETTE, PC; BELAND, M; KUGLER, JD; OCONNOR, BK; ALLENDER, H; HERNDON, SP; SMITH, RT; BURTON, D; KURER, CC; BYRUM, C; GUAM, WE; FRIEDMAN, R; PERRY, JC; SCOTT, W; MEHTA, AV; PICKHOFF, AS; FISH, F; YEAGER, S; KAWABORI, [No Value; TRIPPLE, M; ROSENFELD, LE

    Background. During the past decade. the implantable cardioverter-defibrillator (ICD) has emerged as the primary therapeutic option for survivors of sudden cardiac death (SCD). Investigation of the clinical efficacy of these devices has primarily assessed outcome in adults with coronary artery

  19. Very high rate programming in primary prevention patients with reduced ejection fraction implanted with a defibrillator: Results from a large multicenter controlled study.

    Science.gov (United States)

    Clementy, Nicolas; Challal, Farid; Marijon, Eloi; Boveda, Serge; Defaye, Pascal; Leclercq, Christophe; Deharo, Jean-Claude; Sadoul, Nicolas; Klug, Didier; Piot, Olivier; Gras, Daniel; Bordachar, Pierre; Algalarrondo, Vincent; Fauchier, Laurent; Babuty, Dominique

    2017-02-01

    Programming implantable cardioverter-defibrillators (ICDs) with a high-rate therapy strategy has proven to be effective in reducing shocks and is associated with a reduced mortality. We sought to determine the impact of a very high rate cutoff programming strategy on outcomes in patients with a primary indication for an ICD due to reduced left ventricular ejection fraction. Using data from the multicenter French DAI-PP registry, this cohort-controlled study compared outcomes in 500 patients programmed with a very high rate cutoff (VH-RATE group: monitor zone 170-219 beats/min; ventricular fibrillation zone ≥220 beats/min with 13 ± 4 detection intervals) with 1500 matched control patients programmed with 1 or 2 therapy zone. All ICDs were implanted for primary prevention in patients with systolic dysfunction. Risks of events were compared after propensity score matching of sex, age, ejection fraction, New York Heart Association class, cardiomyopathy, atrial fibrillation, and type of device. After a mean follow-up of 3.6 ± 2.3 years, VH-RATE programming was associated with a reduction of appropriate therapy risk (hazard ratio [HR] 0.40; 95% confidence interval [CI] 0.31-0.51; P programmed with 2 therapy zones. There was no significant difference in overall survival between the groups. In patients implanted with an ICD in primary prevention with left ventricular dysfunction, very high rate cutoff programming (single therapy zone ≥220 beats/min) was associated with a 60% reduction of appropriate therapies as well as inappropriate shocks, without affecting mortality. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  20. Arrhythmia Diagnosis Following an ICD Shock: Reply

    Directory of Open Access Journals (Sweden)

    Roy M. John

    2002-01-01

    Full Text Available Dr. Levine's comments1 are greatly appreciated. Most modern ICDs have arrhythmia discrimination algorithms that have variable success in withholding inappropriate therapy. It must be borne in mind that enhancing specificity for ventricular arrhythmia detection can entail a loss of sensitivity. Accordingly, all algorithms necessarily err on the side of safety and will withhold therapy for only brief period of time. A persistent high rate will eventually be treated as a ventricular arrhythmia and can result in unnecessary and repetetive shocks. Hence the importance of aggressive management of supraventricular arrhythmias in these patients cannot be overemphasized. The patient presented in the case study2 had an older generation single chamber ICD. Although, the provocation of ventricular tachycardia by anti-tachycardia pacing led to an ICD shock and termination of the atrial arrhythmia in this particular instance, atrial arrhythmias are often not terminated by ICD shocks delivered between an RV lead and the generator can. Further therapies with repeated induction of VT could have resulted. In patients with severe LV dysfunction or ischemia, such arrhythmias have a potential for progression to intractable ventricular fibrillation and death. The modern dual chamber detection algorithms have significantly improved specificity for ventricular arrhythmia detection. I am in total agreement with Dr. Levine regarding the programming of monitoring zones in the early post implant period. When done correctly, such programming can provide a great deal of information on arrhythmia characteristics and accuracy of discrimination algorithms.

  1. Employment Status and Sick Leave After First-Time Implantable Cardioverter Defibrillator Implantation

    DEFF Research Database (Denmark)

    Christensen, Anne Vinggaard; Øhlers, Anne Alexandrine; Zwisler, Ann Dorthe

    2017-01-01

    BACKGROUND:: In the Copenhagen Outpatient Programme–Implantable Cardioverter Defibrillator (COPE-ICD) Trial, a positive effect from a cost-saving, comprehensive cardiac rehabilitation program was found on physical and mental health in patients with ICDs. OBJECTIVE:: In the context of the COPE...... of employment status and sick leave were tested using logistic regression and linear regression models. RESULT:: A total of 196 patients were randomized. The questionnaire was completed by 138 patients (70%). In total, 47% had worked before ICD implantation. After 1 year, 81% were still working and their mean...

  2. Ventricular Arrhythmias in Apparently Normal Hearts: Who Needs an Implantable Cardiac Defibrillator?

    Science.gov (United States)

    Tan, Alex Y; Ellenbogen, Kenneth

    2016-09-01

    Idiopathic ventricular tachycardia is often considered a benign form of ventricular arrhythmia in patients without apparent structural heart disease. However, a subset of patients may develop malignant ventricular arrhythmias and present with syncope and sudden cardiac arrest. Survivors of cardiac arrest are candidates for implantable cardiac defibrillators (ICDs). The indications for ICDs in patients with less than a full-blown cardiac arrest presentation but with electrocardiographically high-risk ectopy features remain uncertain. This article addresses some of the uncertainties and pitfalls in ICD risk stratification in this patient group and explores potential mechanisms for malignant conversion of benign premature ventricular complexes to sustained arrhythmia.

  3. Patient-tailored implantable cardioverter defibrillator testing using the upper limit of vulnerability: the TULIP protocol.

    Science.gov (United States)

    Lemke, Bernd; Lawo, Thomas; Zarse, Markus; Lubinski, Andrzej; Kreutzer, Ulrich; Mueller, Johannes; Schuchert, Andreas; Mitzenheim, Sabine; Danilovic, Dejan; Deneke, Thomas

    2008-08-01

    We evaluated the feasibility of the TULIP (Threshold test using Upper Limit during ImPlantation) protocol, which was designed to provide a confirmed, low defibrillation energy value during implantable cardioverter defibrillator (ICD) implantation with only two induced ventricular fibrillation (VF) episodes. Ninety-eight patients (62 +/- 12 years, 86 male) from 13 clinical centres underwent an active can ICD implantation. A single coupling interval derived from electrocardiogram lead II during ventricular pacing was used for VF induction shocks at 13, 11, 9, and 6 J in a step-down manner until the upper limit of VF induction (ULVI) was determined. If ULVI >or=9 J, a defibrillation energy of ULVI + 4 J was tested. For ULVI <9 J, the defibrillation test energy was 9 J. In 79/98 patients (80.6%), two induced VF episodes were sufficient to obtain confirmed defibrillation energy of 11.1 +/- 3.3 J. The mean strength of the successful VF induction shock was 6.8 +/- 4.3 J, the coupling interval was 303 +/- 35 ms, and the number of delivered induction shocks until the first VF induction was 3.9 +/- 1.6. TULIP is a safe and simple device testing procedure allowing the determination of confirmed, low defibrillation energy in most patients with two VF episodes induced at a single coupling interval.

  4. Complex PTSD as Proposed for ICD-11: Validation of a New Disorder in Children and Adolescents and Their Response to Trauma-Focused Cognitive Behavioral Therapy

    Science.gov (United States)

    Sachser, Cedric; Keller, Ferdinand; Goldbeck, Lutz

    2017-01-01

    Background: To evaluate whether the symptoms of children and adolescents with clinically significant posttraumatic stress symptoms (PTSS) form classes consistent with the diagnostic criteria of complex PTSD (CPTSD) as proposed for the ICD-11, and to relate the emerging classes with treatment outcome of Trauma-Focused Cognitive Behavioral Therapy…

  5. Complex PTSD as Proposed for ICD-11: Validation of a New Disorder in Children and Adolescents and Their Response to Trauma-Focused Cognitive Behavioral Therapy

    Science.gov (United States)

    Sachser, Cedric; Keller, Ferdinand; Goldbeck, Lutz

    2017-01-01

    Background: To evaluate whether the symptoms of children and adolescents with clinically significant posttraumatic stress symptoms (PTSS) form classes consistent with the diagnostic criteria of complex PTSD (CPTSD) as proposed for the ICD-11, and to relate the emerging classes with treatment outcome of Trauma-Focused Cognitive Behavioral Therapy…

  6. A computer modeling tool for comparing novel ICD electrode orientations in children and adults.

    Science.gov (United States)

    Jolley, Matthew; Stinstra, Jeroen; Pieper, Steve; Macleod, Rob; Brooks, Dana H; Cecchin, Frank; Triedman, John K

    2008-04-01

    Use of implantable cardiac defibrillators (ICDs) in children and patients with congenital heart disease is complicated by body size and anatomy. A variety of creative implantation techniques has been used empirically in these groups on an ad hoc basis. To rationalize ICD placement in special populations, we used subject-specific, image-based finite element models (FEMs) to compare electric fields and expected defibrillation thresholds (DFTs) using standard and novel electrode configurations. FEMs were created by segmenting normal torso computed tomography scans of subjects ages 2, 10, and 29 years and 1 adult with congenital heart disease into tissue compartments, meshing, and assigning tissue conductivities. The FEMs were modified by interactive placement of ICD electrode models in clinically relevant electrode configurations, and metrics of relative defibrillation safety and efficacy were calculated. Predicted DFTs for standard transvenous configurations were comparable with published results. Although transvenous systems generally predicted lower DFTs, a variety of extracardiac orientations were also predicted to be comparably effective in children and adults. Significant trend effects on DFTs were associated with body size and electrode length. In many situations, small alterations in electrode placement and patient anatomy resulted in significant variation of predicted DFT. We also show patient-specific use of this technique for optimization of electrode placement. Image-based FEMs allow predictive modeling of defibrillation scenarios and predict large changes in DFTs with clinically relevant variations of electrode placement. Extracardiac ICDs are predicted to be effective in both children and adults. This approach may aid both ICD development and patient-specific optimization of electrode placement. Further development and validation are needed for clinical or industrial utilization.

  7. Changes in psychosocial distress in outpatients with heart failure with implantable cardioverter defibrillators.

    Science.gov (United States)

    Thomas, Sue A; Friedmann, Erika; Gottlieb, Stephen S; Liu, Fang; Morton, Patricia G; Chapa, Deborah W; Lee, Hyeon-Joo; Nahm, Eun-Shim

    2009-01-01

    Patients given implantable cardioverter defibrillators (ICDs) after arrhythmic events or sudden cardiac arrest (SCA) experience psychosocial distress. ICDs now are inserted for the primary prevention of SCA in patients with heart failure; the psychosocial impact of ICDs on patients with heart failure is unknown. Changes in psychosocial status in these ICD recipients were examined. ICD recipients (n = 57) completed depression, anxiety, and social support inventories every 6 months for up to 2 years. Initially, 35% of recipients were depressed and 45% of recipients were anxious. In linear mixed models, depression decreased over time overall but increased in those who experienced ICD shocks. Anxiety decreased in New York Heart Association class III ICD recipients but not in class II ICD recipients. Decreases in social support were related to age: the younger the patient the greater the decrease. A significant proportion of ICD recipients were depressed or anxious, or had diminished social support even after 2 years. Investigation of strategies to improve ICD recipients' psychosocial status is warranted.

  8. Implantable cardioverter defibrillator - discharge

    Science.gov (United States)

    ... hair dryer, stove, CD player, remote controls, and microwave. There are several devices you should keep at ... Tell your provider about every shock you feel from your ICD. The settings of your ICD may need to be adjusted, or your medicines may need to ...

  9. Prophylactic left thoracic sympathectomy to prevent electrical storms in CPVT patients needing ICD placement.

    Science.gov (United States)

    Moray, Amol; Kirk, Edwin P; Grant, Peter; Camphausen, Christoph

    2011-11-01

    Catecholaminergic Polymorphic Ventricular Tachycardia (CPVT), a life threatening arrhythmia induced by sympathetic stimulation in susceptible individuals is often refractory to antiarrhythmic agents. First line of treatment, beta-blockers can be ineffective in up to 50% with implantable cardioverter-defibrillator (ICD) placement for refractory cases. Paradoxically ICD can be arryhthmogenic from shock-associated sympathetic stimulation, initiating more shocks and "electrical storms". This has led to the use of more effective beta blockade offered by left sympathectomy, now performed by minimally invasive video assisted thoracoscopic surgery (VATS). Sympathectomy has been traditionally performed long after ICD placement, after the patient has experienced multiple shocks, thus necessitating two procedures. We report simultaneous ICD insertion and thoracoscopic sympathectomy in a 10 year-old boy with CPVT, and suggest it as a better approach than sequential procedures. To our knowledge this is first such reported case.

  10. Bilateral Subclavian Vein Occlusion in a SAPHO Syndrome Patient Who Needed an Implantable Cardioverter Defibrillator.

    Science.gov (United States)

    Ishizuka, Masato; Yamamoto, Yuko; Yamada, Shintaro; Maemura, Sonoko; Nakata, Ryo; Motozawa, Yoshihiro; Yamamoto, Keisuke; Takizawa, Masataka; Uozumi, Hiroki; Ikenouchi, Hiroshi

    2016-05-25

    A 79-year-old Asian man was hospitalized because of progressive exertional dyspnea with decreasing left ventricular ejection fraction and frequent non-sustained ventricular tachycardia. Pre-procedure venography for implantable cardioverter defibrillator (ICD) implantation showed occlusion of the bilateral subclavian veins. In consideration of subcutaneous humps in the sterno-clavicular area and palmoplantar pustulosis, we diagnosed him as having synovitis, acne, pustulosis, hyperostosis, osteitis (SAPHO) syndrome and speculated that it induced peri-osteal chronic inflammation in the sterno-clavicular area, resulting in occlusion of the adjacent bilateral subclavian veins. An automatic external defibrillator (AED) was installed in the patient's house and total subcutaneous ICD was considered. Venous thrombosis in SAPHO syndrome is not frequent but has been reported. To the best of our knowledge, this is the first case of bilateral subclavian vein occlusion in a SAPHO syndrome patient who needs ICD implantation.

  11. Randomized Clinical evaluatiON of wireless fluid monitoriNg and rEmote ICD managemenT using OptiVol alert-based predefined management to reduce cardiac decompensation and health care utilization: the CONNECT-OptiVol study.

    Science.gov (United States)

    Zabel, Markus; Vollmann, Dirk; Lüthje, Lars; Seegers, Joachim; Sohns, Christian; Zenker, Dieter; Hasenfuss, Gerd

    2013-01-01

    The CONNECT-OptiVol study is designed to investigate whether wireless fluid monitoring using OptiVol alerts as well as implantable cardioverter-defibrillator (ICD) remote monitoring (RM) reduces cardiac decompensations and health care utilization in ICD patients, as compared to standard clinical care. Patients undergoing implantation of wireless telemetry-enabled dual chamber (ICD-DR) or cardiac resynchronization therapy/defibrillator (CRT-D) devices with the OptiVol feature are eligible for the study. In a randomized fashion, OptiVol function, its audible alert as well as its remote alert, and other ICD RM alerts are switched ON or OFF. The primary study objective is to estimate an improvement of heart failure status. The primary endpoint is measured as a prolongation of the time to first hospitalization due to worsened heart failure. The secondary objectives are to estimate: a reduction of the time from event to clinical decision, a reduction of the rate of health care utilization, and improved quality of life (QoL) measures (secondary endpoints). The study is designed as a single center pilot study with 180 patients randomized 1:1 to the two study arms. The CONNECT-OptiVol study aims to answer whether wireless fluid monitoring integrated into RM may reduce cardiac decompensations and health care utilization in ICD patients. The results can be used to adequately power future studies evaluating the benefit of these features. Study enrollment has been completed, and follow-up is expected to be finished in September 2012. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Initial experience with the subcutaneous implantable cardioverter-defibrillator in a single Japanese center

    Directory of Open Access Journals (Sweden)

    Nobuhiro Nishii, MD

    2017-08-01

    Conclusions: S-ICD implantation appears to provide a viable alternative to transvenous ICD implantation for some Japanese patients. However, we should perform careful follow-up of patients to eliminate inappropriate therapy.

  13. Strategies for ICD-10 implementation.

    Science.gov (United States)

    Zeisset, Ann; Bowman, Sue

    2012-09-01

    Hospitals and health systems should consider seven strategies for preparing for the conversion from ICD-9-CM to ICD-10-CM/PCS: Form a project planning team. Assess the range of impact on each department and on productivity, revenue, and resources. Perform a gap analysis. Analyze data. Develop a training strategy specific to coding professionals and heavy data users. Work to improve documentation. Communicate with vendors regarding their plans for the transition to ICD-10.

  14. Cardiac resynchronization therapy improves psycho-cognitive performance in patients with heart failure.

    Science.gov (United States)

    Duncker, David; Friedel, Katrin; König, Thorben; Schreyer, Hendrik; Lüsebrink, Ulrich; Duncker, Mareke; Oswald, Hanno; Klein, Gunnar; Gardiwal, Ajmal

    2015-09-01

    Reduced cognitive performance and high prevalence of depression have been reported in patients with congestive heart failure (CHF) and severe left ventricular dysfunction. However, effects of contemporary device therapy on cognitive performance and depression symptoms have not been studied thoroughly. Seventy-four consecutive CHF patients-45 receiving a biventricular defibrillator (CRT-D) and 29 receiving an implantable single or dual-chamber defibrillator (ICD) as a control group-were enrolled in this investigator-initiated, prospective, controlled, and investigator-blinded study. A set of neuropsychological tests (mini-mental state examination, DemTect, age-concentration test, and Beck depression inventory) was performed before, at 3 and at 6 months after device implantation. DemTect-score improved significantly (F = 7.8; P = 0.007) after CRT-D-implantation compared with ICD. Age-concentration test revealed better concentration ability after CRT-D-implantation (F = 8.3; P = 0.005) compared with ICD. Under CRT-D mini-mental state examination showed a significant improvement (F = 4.2; P = 0.043). CRT with defibrillator therapy also improved depression revealed by beck depression inventory (F = 14.7; Pcognitive improvement by resynchronization therapy in CHF patients with severe left ventricular dysfunction. In contrast to ICD therapy, the beneficial effect of CRT-D on psycho-cognitive performance might be attributed to improved cardiac function and haemodynamics. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  15. Implantable cardioverter-defibrillator

    Science.gov (United States)

    ... the heart to beat in a more coordinated fashion. Why the Procedure is Performed An ICD is ... Controlling your high blood pressure Dietary fats explained Fast food tips Heart attack - discharge Heart disease - risk ...

  16. [Treatment manual for psychotherapy of acute and posttraumatic stress disorders after multiple ICD shocks].

    Science.gov (United States)

    Jordan, J; Titscher, G; Kirsch, H

    2011-09-01

    In view of the inceasing number of implanted defibrillators in all industrial nations, the number of people who have suffered so-called multiple shocks (electrical storm, ES) also increases. Common complaints are severe and continuously recurrent massive anxiety, panic attacks, fear of death, helplessness and hopelessness, depression, nervosity and irritability as well as reclusive and uncontrollable avoidance behaviour, intrusions, nightmares, flashbacks, sleeplessness and the inability to show feelings and limitation of future perspectives. Because people with an ICD are often physically (very) ill and after multiple ICD shocks are additionally very insecure, it would seem logical if the inpatient treatment would be carried out in an institution which has close connections and is also spatially close to a cardiology department. The basis of the diagnostics is the clinical anamnesis and a systematic exploration of the trauma situation and the resulting complaints. As an additional diagnostic element psychological test procedures should be implemented to determine the core symptomatic (anxiety, depression, trauma symptoms). Psychological test procedures should be included in the diagnostics so that at the end of treatment it is obvious even to the patient which alterations have occurred. The core element of inpatient treatment is daily intensive psychotherapy and includes deep psychologically well-founded psychotherapy and behavioral therapeutic-oriented anxiety therapy as well as cognitive restructuring and elements of eye movement desensitization and reprocessing (EMDR). A follow-up examination within 4 months of the multiple shocks episode is recommended because symptoms of posttraumatic stress disorder often occur after a long latent time period.

  17. Patient-reported outcomes in Danish implantable cardioverter defibrillator patients with a Sprint Fidelis lead advisory notification

    DEFF Research Database (Denmark)

    Pedersen, Susanne S; Versteeg, Henneke; Nielsen, Jens Cosedis;

    2011-01-01

    Few studies have investigated the association between implantable cardioverter defibrillators (ICDs) and lead advisory notifications and patient-reported outcomes (PROs). We examined (i) whether the mode used to inform patients about a device advisory is associated with PROs, and (ii) whether pat...

  18. Morphology discrimination in implantable cardioverter-defibrillators: Consistency of template match percentage during atrial tachyarrhythmias at different heart rates

    NARCIS (Netherlands)

    D.A.M.J. Theuns (Dominic); M. Rivero-Ayerza (Maximo); D. Goedhart (Dick); M. Miltenburg (Max); L.J.L.M. Jordaens (Luc)

    2008-01-01

    textabstractBackground: Morphology discrimination (MD) in implantable cardioverter-defibrillators (ICDs) is based on the comparison of the ventricular electrogram during tachycardia with a stored reference template obtained during baseline rhythm. However, the effect of heart rate on the template ma

  19. Psychological Functioning and Disease-Related Quality of Life in Pediatric Patients With an Implantable Cardioverter Defibrillator

    NARCIS (Netherlands)

    Koopman, H. M.; Vrijmoet-Wiersma, C. M. J.; Langius, J. N. D.; van den Heuvel, F.; Clur, S. A.; Blank, C. A.; Blom, N. A.; ten Harkel, A. D. J.

    2012-01-01

    The objective of this multicenter study was to evaluate psychological functioning and disease-related quality of life (DRQoL) in pediatric patients with an implantable cardioverter defibrillator (ICD) in The Netherlands. Thirty patients were investigated; the mean age was 16.3 years, and the mean du

  20. Shock and patient preimplantation type D personality are associated with poor health status in patients with implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Tekle, Fetene B; Hoogwegt, Madelein T

    2012-01-01

    Implantable cardioverter-defibrillator (ICD) shock is a critical event to patients associated with well-being after implantation, although other factors may play an equally important role. We compared the association of shock and the patient's preimplantation personality with health status, using...

  1. Contact dermatitis after implantable cardiac defibrillator implantation for ventricular tachycardia.

    Science.gov (United States)

    Dogan, Pinar; Inci, Sinan; Kuyumcu, Mevlut Serdar; Kus, Ozgur

    2016-02-01

    Pacemaker contact sensitivity is a rare condition. Less than 30 reports of pacemaker skin reactions have been described. We report a 57-year-old woman who underwent an implantable cardiac defibrillator (ICD) implantation for ventricular tachycardia. A skin patch test was positive on almost all components of the pacemaker system. She was treated with topical corticosteroids and skin lesions resolved within 2 weeks. Because of widespread use of various devices, we will see this more often and therefore it is important to recognize this problem and its effective management.

  2. Age and Outcomes of Primary Prevention Implantable Cardioverter Defibrillators in Patients with Non-Ischemic Systolic Heart Failure

    DEFF Research Database (Denmark)

    Elming, Marie Bayer; Nielsen, Jens C; Haarbo, Jens

    2017-01-01

    Background -The Danish Study to Assess the Efficacy of Implantable Cardioverter Defibrillators (ICD) in Patients with Non-ischemic Systolic Heart Failure on Mortality (DANISH) did not demonstrate an overall effect on all-cause mortality with ICD implantation. However, the pre-specified subgroup...... investigation. Methods -All 1116 patients from the DANISH study were included in this pre-specified subgroup analysis. We assessed the relationship between the ICD and mortality by age, and an optimal age cut-off was estimated non-parametrically using selection impact curves. Modes of death were divided...

  3. Postimplantation ventricular ectopic burden and clinical outcomes in cardiac resynchronization therapy-defibrillator patients: a MADIT-CRT substudy.

    Science.gov (United States)

    Ruwald, Anne-Christine; Aktas, Mehmet K; Ruwald, Martin H; Kutyifa, Valentina; McNitt, Scott; Jons, Christian; Mittal, Suneet; Steinberg, Jonathan S; Daubert, James P; Moss, Arthur J; Zareba, Wojciech

    2017-09-20

    Frequent ventricular ectopy on preimplantation Holter has been associated with attenuated benefit from cardiac resynchronization therapy (CRT). However, it is unclear whether ectopic burden measured post-CRT implantation can be utilized to evaluate long-term prognosis. We aimed to describe the association between post-CRT implantation ectopic burden and subsequent risk of clinical outcomes. At the 12-month follow-up visit, 24-hour Holter recordings were performed in 698 CRT-D patients from the MADIT-CRT study. The mean number of ventricular premature complexes (VPCs/hour) was calculated. High ectopic burden was defined as >10 VPCs/hour and low burden as ≤10 VPCs/hour. Multivariate Cox proportional hazards models were utilized to assess the association between 12-month ectopic burden and the risk of the end points of heart failure (HF) or death and ventricular tachyarrhythmias (VT/VF). At 12 months, 282 (40%) patients presented with low ectopic burden and 416 (60%) patients presented with high ectopic burden. The 3-year risk of HF/death and VT/VF was lower in patients with a low burden (7% and 8%) and significantly higher (25% and 24%) in patients with high burden. In multivariate analyses, patients with a high ectopic burden had approximately threefold increased risk of both HF/death (HR=2.76 [1.62-4.70], p ectopic burden at 12-month follow-up was associated with a high 3-year risk of HF/death and VT/VF and threefold increased risk as compared to patients with low burden. Ectopic burden at 12 months may be a valuable approach for evaluating long-term prognosis. © 2017 Wiley Periodicals, Inc.

  4. The gulf implantable cardioverter-defibrillator registry: Rationale, methodology, and implementation

    Directory of Open Access Journals (Sweden)

    Alawi A Alsheikh-Ali

    2015-01-01

    Conclusions: Gulf ICD is the first prospective, observational, multi-center, and multinational study of the characteristics and, the outcomes of patients receiving ICDs in the Arab Gulf region. The study will provide valuable insights into the utilization of and outcomes related to ICD therapy in the Gulf region.

  5. The Cause Analysis and Countermeasures of Frequent Shocks in Patients with Implantable Cardioverter Defibrillator%埋藏式心脏除颤器患者频繁电击原因分析及对策

    Institute of Scientific and Technical Information of China (English)

    吴冬燕; 邢彩耐; 卢凤民; 付乃宽; 许静

    2014-01-01

    Objective To investigate the cause and countermeasures of frequent shocks in patients with implantable cardioverter defibrillators (ICD). Methods Eighty ICD patients with heart failure and malignant ventricular arrhythmias were followed up, including sixty-two male and eighteen female patients. There were 35 patients with single-chamber ICD, 23 with dual-chamber ICD and 22 with three-chamber ICD. Patients in this study were followed up for 1-6 years to analyze the reasons for ICD discharge. According to the specific circumstances, patients were treated. Results Twenty-three pa-tients in 80 patients suffered from shock treatment. Ten patients (12.5%) experienced frequent shocks. The causes of fre-quent shock included repeated episodes of ventricular tachycardia, invalid shock due to increased defibrillation threshold (DF) and false identification of the frequent episodes of paroxysmal ventricular tachycardia or arrhythmias. The management included the identification process adjustment of ventricular tachycardia and supraventricular tachycardia, increased num-bers of beats of ventricular tachycardia judgment and increase the basic pacing rate. The anti-arrhythmic drugs should be combinedly used, especially metoprolol and amiodarone. The ICD shock was significantly reduced after parameter optimiza-tion and anti-arrhythmic therapy. Conclusion The ICD shocks were effectively reduced with rational use of anti-arrhyth-mic drugs and valid ICD programming.%目的:探讨植入埋藏式心脏除颤器(ICD)的患者出现频繁放电的原因及处理方法。方法随访80例因心力衰竭或恶性室性心律失常植入ICD的患者,男62例,女18例,其中单腔ICD 35例,双腔ICD 23例,三腔ICD (CRTD)22例,随访1~6年,了解ICD的放电原因,并根据具体情况进行治疗。结果80例患者中有23例患者遭受电击,其中10例为频繁电击(24 h内电击≥3次或1年内电击≥5次),均为心脏猝死二级预防患者。

  6. Predictive Modeling of Defibrillation utilizing Hexahedral and Tetrahedral Finite Element Models: Recent Advances

    Science.gov (United States)

    Triedman, John K.; Jolley, Matthew; Stinstra, Jeroen; Brooks, Dana H.; MacLeod, Rob

    2008-01-01

    ICD implants may be complicated by body size and anatomy. One approach to this problem has been the adoption of creative, extracardiac implant strategies using standard ICD components. Because data on safety or efficacy of such ad hoc implant strategies is lacking, we have developed image-based finite element models (FEMs) to compare electric fields and expected defibrillation thresholds (DFTs) using standard and novel electrode locations. In this paper, we review recently published studies by our group using such models, and progress in meshing strategies to improve efficiency and visualization. Our preliminary observations predict that they may be large changes in DFTs with clinically relevant variations of electrode placement. Extracardiac ICDs of various lead configurations are predicted to be effective in both children and adults. This approach may aid both ICD development and patient-specific optimization of electrode placement, but the simplified nature of current models dictates further development and validation prior to clinical or industrial utilization. PMID:18817926

  7. Epileptic seizure in a patient with an implantable cardioverter-defibrillator: Quo vadis right ventricular lead?

    Science.gov (United States)

    Wedekind, Horst; Rozhnev, Andrey; Kleine-Katthöfer, Peter; Kranig, Wolfgang

    2016-03-01

    The case of a 77-year-old man admitted for suspected epileptic seizure is reported. Patient history showed implantation of a single-chamber implantable cardioverter-defibrillator (ICD) after cardiac arrest in 2007 with replacement in 2012 due to battery depletion; the patient reported no previous syncope, unconsciousness or seizures. Interrogation records of the ICD showed five ventricular tachyarrhythmia episodes that corresponded to the "seizure". Further examination revealed incorrect position of the RV-lead. Diagnosis was a provoked epileptic seizure due to undersensing of ventricular tachycardia because of improper ICD lead implantation in the coronary sinus. Treatment consisted of implantation of a new device with an additional ICD lead into the right ventricle.

  8. Gender disparities in psychological distress and quality of life among patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; van den Broek, Krista C; Denollet, Johan

    2011-01-01

    disparities in psychological distress and QoL in ICD patients by means of a systematic review, and (2) provide recommendations for future research and clinical implications. A systematic search of the literature identified 18 studies with a sample size ≥ 100 that examined gender disparities in anxiety......A subset of patients with an implantable cardioverter defibrillator (ICD) reports psychological distress and poor quality of life (QoL). Gender is one of the factors that has been proposed to explain individual differences in these outcomes. In this viewpoint, we (1) review the evidence for gender....../depression and QoL in ICD patients (mean prevalence of women = 21%; mean age = 62 years). Our review shows that there is insufficient evidence to conclude that gender per se is a major autonomous predictor for disparities in psychological distress and QoL in ICD patients. Women had a higher prevalence of anxiety...

  9. Towards Low Energy Atrial Defibrillation

    Directory of Open Access Journals (Sweden)

    Philip Walsh

    2015-09-01

    Full Text Available A wireless powered implantable atrial defibrillator consisting of a battery driven hand-held radio frequency (RF power transmitter (ex vivo and a passive (battery free implantable power receiver (in vivo that enables measurement of the intracardiac impedance (ICI during internal atrial defibrillation is reported. The architecture is designed to operate in two modes: Cardiac sense mode (power-up, measure the impedance of the cardiac substrate and communicate data to the ex vivo power transmitter and cardiac shock mode (delivery of a synchronised very low tilt rectilinear electrical shock waveform. An initial prototype was implemented and tested. In low-power (sense mode, >5 W was delivered across a 2.5 cm air-skin gap to facilitate measurement of the impedance of the cardiac substrate. In high-power (shock mode, >180 W (delivered as a 12 ms monophasic very-low-tilt-rectilinear (M-VLTR or as a 12 ms biphasic very-low-tilt-rectilinear (B-VLTR chronosymmetric (6ms/6ms amplitude asymmetric (negative phase at 50% magnitude shock was reliably and repeatedly delivered across the same interface; with >47% DC-to-DC (direct current to direct current power transfer efficiency at a switching frequency of 185 kHz achieved. In an initial trial of the RF architecture developed, 30 patients with AF were randomised to therapy with an RF generated M-VLTR or B-VLTR shock using a step-up voltage protocol (50–300 V. Mean energy for successful cardioversion was 8.51 J ± 3.16 J. Subsequent analysis revealed that all patients who cardioverted exhibited a significant decrease in ICI between the first and third shocks (5.00 Ω (SD(σ = 1.62 Ω, p < 0.01 while spectral analysis across frequency also revealed a significant variation in the impedance-amplitude-spectrum-area (IAMSA within the same patient group (|∆(IAMSAS1-IAMSAS3[1 Hz − 20 kHz] = 20.82 Ω-Hz (SD(σ = 10.77 Ω-Hz, p < 0.01; both trends being absent in all patients that failed to cardiovert

  10. [Magnets, pacemaker and defibrillator: fatal attraction?].

    Science.gov (United States)

    Bergamin, C; Graf, D

    2015-05-27

    This article aims at clarifying the effects of a clinical magnet on pacemakers and Implantable Cardioverter Defibrillators. The effects of electromagnetic interferences on such devices, including interferences linked to electrosurgery and magnetic resonance imaging are also discussed. In general, a magnet provokes a distinctive effect on a pacemaker by converting it into an asynchronous mode of pacing, and on an Implantable Cardioverter Defibrillator by suspending its own antitachyarythmia therapies without affecting the pacing. In the operating room, the magnet has to be used cautiously with precisely defined protocols which respect the type of the device used, the type of intervention planned, the presence or absence of EMI and the pacing-dependency of the patient.

  11. The National Survey of Cardiac Pacemakers and Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Gholamrerza Shafieian

    2006-07-01

    Full Text Available Background: Permanent pacemakers provide effective relief of symptoms and are life-saving in patients with symptomatic heart block. Implantable cardioverter defibrillators (ICD are also increasingly recognized as life-saving tools in various groups of patients with malignant ventricular tachyarrhythmias. Methods: As part of the “world survey on pacemaker and ICD implantations”, a survey of all device implantations in Iran during the year 2001 was performed. Data was collected and cross-checked through three sources i.e. direct contact with implanting physicians, pacemaker companies and the governmental pacemaker distributing body.Results: During the year studied, 1635 patients received permanent pacemakers. 88% were new implants at an estimated rate of 24 per million population. The mean age of patients was 65 years and 56.2% were male. 40 cardiologists and 19 surgeons implanted the pacemakers at 27 centers throughout the country. Complete heart block was consistently the most common indication at all centers (mean 56.1%, sick sinus syndrome being the next most common one (mean 20.8%. 69% of the pacemakers were single chamber pacemakers. Transvenous insertion of bipolar steroid-eluting passive fixation leads was the predominant practice at most centers. A total of 60 ICDs were implanted at 7 centers by 9 cardiologists. 45% of ICD implants were dual chamber devices.Conclusion: The survey is the only one available right now and provides useful information about the prevailing pacemaker and defibrillator implantation practice in Iran. Future surveys would be facilitated if a standardized implant registry such as that used in Europe were established in this country.

  12. [Implantable cardioverter-defibrillator deactivation at the end of life: ethical, clinical and communication issues].

    Science.gov (United States)

    Romanò, Massimo; Piga, Maria Antonella; Bertona, Roberta; Negro, Roberto; Ruggeri, Chiara; Zorzoli, Federica; Villani, Rosvaldo

    2017-02-01

    The number of cardioverter-defibrillator implants is increasing worldwide, with the main indication being primary prevention of sudden cardiac death. During the follow-up, patients may die from progression of their underlying heart disease or from nonarrhythmic causes, such as malignancies, dementia and lung disease, without receiving appropriate shocks until the last few days or weeks of their life. These events occur roughly in 30% of patients, mainly in the last 24 hours before death. In this case, inappropriate and even appropriate shock deliveries can no longer prolong life and may simply lead to pain and reduced quality of life. Therefore, it appears important to discuss early with the patients and their relatives about deactivation of the implantable cardioverter-defibrillator (ICD) at the end of life.The goal of this review is to provide an overview of the ethical, clinical and communication issues of ICD deactivation, with a special focus on patients' wishes. It is outlined that patients are not adequately informed about risks and benefits of ICD and the option of ICD deactivation; the doctors are not used to discuss with the patients the topics of end-of-life decisions. Complete information must be part of current informed consent before ICD implantation and should be updated during the follow-up, with special attention to patients with heart failure in relation to their prognosis and advance directives, as suggested by international guidelines.

  13. A comparison of the health status and psychological distress of partners of patients with a left ventricular assist device versus an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; Caliskan, Kadir; de Jonge, Nicolaas;

    2014-01-01

    OBJECTIVE: To examine if the caregiving for patients with a left ventricular assist device (LVAD) is related to a poorer health status and more distress compared to patients with an implantable cardioverter defibrillator (ICD). BACKGROUND: Partners distress may influence patient outcomes and is t......OBJECTIVE: To examine if the caregiving for patients with a left ventricular assist device (LVAD) is related to a poorer health status and more distress compared to patients with an implantable cardioverter defibrillator (ICD). BACKGROUND: Partners distress may influence patient outcomes...... (F = 10.71, p = .001) but poorer mental health status (F = 14.82, p compared to ICD partners (F = 3.68, p = .05) at 6 months follow-up, also in adjusted analyses. There was no significant difference between groups on anxiety. CONCLUSION: Caregivers of LVAD...... patients show higher distress levels compared to caregivers of ICD patients. LVAD partners may have a need for support beyond what is offered currently in clinical practice....

  14. Implantable cardioverter defibrillator specific rehabilitation improves health cost outcomes

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Zwisler, Ann-Dorthe; Koch, Mette Bjerrum

    2015-01-01

    of the rehabilitation group for exercise capacity, general and mental health. The aim of this paper is to explore the long-term health effects and cost implications associated with the rehabilitation programme; more specifically, (i) to compare implantable cardioverter defibrillator therapy history and mortality...... between rehabilitation and usual care groups; (ii) to examine the difference between rehabilitation and usual care groups in terms of time to first admission; and (iii) to determine attributable direct costs. METHODS: Patients with first-time implantable cardioverter defibrillator implantation (n = 196......) were randomized (1:1) to comprehensive cardiac rehabilitation or usual care. Outcomes were measured by implantable cardioverter defibrillator therapy history from patient records and national register follow-up on mortality, hospital admissions and costs. RESULTS: No significant differences were found...

  15. Web-Based Distress Management for Implantable Cardioverter Defibrillator Patients

    DEFF Research Database (Denmark)

    Habibović, Mirela; Denollet, Johan; Cuijpers, Pim

    2017-01-01

    distress post-ICD implantation. The WEB-based distress management program for ICD patients (WEBCARE) was developed to mitigate anxiety and depression and enhance health-related quality of life in ICD patients. This study investigates the 6- and 12-months outcomes. METHOD: A total of 289 consecutive ICD...... patients from 6 referral hospitals in the Netherlands were randomized to either the WEBCARE (n = 146) or usual care (n = 143) group. Patients in the WEBCARE group received an online, 12-weeks fixed, 6 lesson behavioral treatment based on problem solving therapy. Patients in the usual care group receive...... care as usual. RESULTS: Current findings show no significant difference on anxiety, depression or quality of life between the WEBCARE and Usual Care group at 6- and 12-months postimplantation. CONCLUSIONS: In this clinical trial of a Web-based behavioral intervention for ICD patients, the Web...

  16. Prophylactic use of implantable cardioverter-defibrillators in the elderly population

    Institute of Scientific and Technical Information of China (English)

    Yuchuan LIU; Hue-Teh Shih

    2005-01-01

    @@ Introduction Sudden cardiac death (SCD) accounts for approximately 300,000 deaths each year in the United States. Ventricular fibrillation, as the initial event, had been reported in 65%-85% of these patients.1 An implantable cardioverterdefibrillator (ICD) is the single most effective life saving device to date. The advances in medicine and technology have led to wide spread utilization of defibrillators in developed countries.

  17. Longitudinal changes in intracardiac repolarization lability in patients with implantable cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Abhilash eGuduru

    2013-08-01

    Full Text Available Background─While it is known that elevated baseline intracardiac repolarization lability is associated with the risk of fast ventricular tachycardia (FVT /ventricular fibrillation (VF, the effect of its longitudinal changes on the risk of FVT/VF is unknown. Methods and Results─Near-field (NF right ventricular (RV intracardiac electrograms (EGMs were recorded every 3-6 months at rest in 248 patients with structural heart disease (mean age 61.2±13.3; 185[75%] male; 162[65.3%] ischemic cardiomyopathy and implanted cardioverter-defibrillator (ICD or cardiac resynchronization therapy defibrillator (CRT-D [201 (81% primary prevention]. Intracardiac beat-to-beat QT variability index (QTVINF was measured on NF RV EGM. During the first study phase (median 18 months, participants made on average 2.4 visits. Then remote follow-up was continued for an additional median period of 3 years. Average QTVINF did not change during the first year after ICD implantation (-0.342±0.603 at baseline vs. -0.262±0.552 at 6 months vs. -0.334±0.603 at 12 months; however, it decreased thereafter (-0.510±0.603 at 18 months; P=0.042. Adjusted population-averaged GEE model showed that the odds of developing FVT/VF increased by 75% for each 1 unit increase in QTVINF. (OR 1.75 [95%CI 1.05-2.92]; P=0.031. However, individual patient–specific QTVINF trends (increasing, decreasing, flat varied from patient to patient. For a given patient, the odds of developing FVT/VF were not associated with increasing or decreasing QTVINF over time (OR 1.27; [95%CI 0.05–30.10]; P = 0.881.Conclusion─While on average the odds of FVT/VF increased with an increase in QTVINF, patient-specific longitudinal trends in QTVINF did not affect the odds of FVT/VF.

  18. Implantable defibrillator lead extraction with optimized standard extraction techniques

    Institute of Scientific and Technical Information of China (English)

    Xian-Ming Chu; Xue-Bin Li; Ping Zhang; Yi An; Jiang-Bo Duan; Long Wang; Ding Li; Bing Li; Ji-Hong Guo

    2013-01-01

    Background Implantable cardioverter-defibrillator (ICD) leads might not be extracted especially in developing countries because of the high cost and lack of specialized tools. We aimed to evaluate transvenous extraction of ICD leads using optimized standard techniques. Methods We prospectively analyzed clinical characteristics, optimized extraction techniques and the feasibility of extraction for 40 patients (33 males; mean age 47.9 ± 16.1 years) with 42 ICD leads. Results Complete procedural success rate was 95.2% (40/42), and the clinical success rate was 97.6% (41/42). One ICD lead required cardiothoracic surgery. Minor complications occurred in three cases (7.5%), and no major complications or death occurred. Locking stylets were used to extract most leads (34, 81.0%) and almost half of the leads (20, 47.6%) required mechanical dilatation to free fibrotic adhesions; these leads had been implanted for a longer period of time than the others (43.7 ± 18.2 vs. 18.4 ± 13.4 months, P < 0.05). Three-quarters of the leads (30, 71.4%) were extracted with locking stylets plus manual traction (12, 28.6%), or mechanical dilatation with counter-traction (18, 42.8%) by the superior vena cava approach and one-quarter of the leads (11, per lead. Linear regression analysis showed that the extraction time was significantly correlated with implant duration (r = 0.70, P < 0.001). optimized procedure for transvenous extraction of ICD leads provides a practical and low-cost method for standard procedures.

  19. Desfibrilador cardioversor automático implantável: experiência inicial Implantable cardioverter defibrillator: initial experience

    Directory of Open Access Journals (Sweden)

    Victor BAUER JÚNIOR

    1999-04-01

    Full Text Available Este estudo tem por objetivo demonstrar o protocolo de implante, técnica utilizada, avaliação dos parâmetros iniciais do implante de desfibrilador cardioversor automático implantável (DCAI e seguimento precoce dos 15 pacientes operados em nosso Serviço. O implante transvenoso nessa série de pacientes obteve sucesso em 14 casos. O limiar de desfibrilação teve média de 8,05 ± 4,60 Joules, onda R 16,00 ± 4,32 mV, "slew rate" 1,25 ± 0,29 V/s, limiar de comando de 0,65 ± 0,80 Volts e resistência de 620,00 ± 102,77 Ohms. O tempo médio de implante foi de 164,17 ± 71,15 minutos. Não ocorreu morte operatória, nem episódios de rejeição ou infecção. A média de seguimento foi de 18,79 ± 13,81 meses sendo que 9 pacientes receberam choques apropriados com reversão das arritmias. Choques inapropriados ocorreram em uma paciente devido à perda do limiar de sensibilidade do cardioversor. Observamos a facilidade técnica do implante utilizando o modelo Phylax 06 na região infraclavicular esquerda com eletrodo único, sendo o DCAI capaz de reconhecer e realizar a terapia de cardioversão ou desfibrilação com sucesso, sugerindo ser um método importante e eficaz para o tratamento dos pacientes que desenvolvem arritmias com alto risco de mortalidade em ambulatório.The implantable cardioverter-defibrillator (ICD is gaining increasing significance in therapy of life-threatening ventricular arrhythmias. Mirowski started to develop experimental automatic implantable defibrillators in the seventies. In 1980, the first human implant of an automatic implantable defibrillator was done by the team of Mirowski in Baltimore, USA. The purpose of this report is to examine 15 implantation at our Institution. Adequate defibrillation thresholds with were obrtained mean 8.0 Joules, slew rate 1.25 V/s and impedance of 620 Ohms. All implants were performed with non-thoracotomy lead, two abdominal implantations and three left pectoral implantations

  20. Cardiopulmonary resuscitation (CPR) plus delayed defibrillation versus immediate defibrillation for out-of-hospital cardiac arrest.

    Science.gov (United States)

    Huang, Yu; He, Qing; Yang, Li J; Liu, Guan J; Jones, Alexander

    2014-09-12

    lists of relevant International Liaison Committee on Resuscitation (ILCOR) evidence worksheets. Our participant group consisted of adults over 18 years of age presenting with OHCA who were in VF or pulseless VT at the time of emergency medical service (EMS) paramedic arrival. We included randomized controlled trials (RCTs) and quasi-randomized controlled trials that evaluated the effects of one and one-half to three minutes of CPR versus defibrillation as initial therapy on survival and neurological outcomes of these participants. We excluded observational and cross-over design studies. Two review authors independently extracted the data. We contacted study authors to ask for additional data when required. The risk ratio (RR) for each outcome was calculated and summarized in the meta-analysis after heterogeneity was considered. We used Review Manager software for all analyses. We included four RCTs with a total of 3090 enrolled participants (one study used a cluster-randomized design). Three trials were considered to have a relatively low risk of bias, and one trial was considered to have a relatively high risk. When survival to hospital discharge was compared, 38 of 320 (11.88%) participants survived to discharge in the initial CPR plus delayed defibrillation group compared with 39 of 338 participants (11.54%) in the immediate defibrillation group (RR 1.09, 95% CI 0.54 to 2.20, Chi(2) = 10.78, degrees of freedom (df) = 5, P value 0.06, I(2) = 54%, low-quality evidence).When we compared the neurological outcome at hospital discharge (RR 1.12, 95% CI 0.65 to 1.93, low-quality evidence), the rate of return of spontaneous circulation (ROSC) (RR 0.94, 95% CI 0.77 to 1.15,low-quality evidence) and survival at one year (RR 0.77, 95% CI 0.24 to 2.49, low-quality evidence), we could not rule out the superiority of either treatment.Adverse effects were not associated with either treatment. Owing to the low quality of available evidence, we have been unable to determine

  1. Awareness among resident doctors with regards to cardiac defibrillators

    Directory of Open Access Journals (Sweden)

    Garg Rakesh

    2010-01-01

    Full Text Available Background and Aims: Electrical defibrillation is the most important therapy for patients in cardiac arrest. The audit was aimed to assess awareness among residents with respect to routine preuse checking of cardiac defibrillators. Materials and Methods: The audit was conducted at a multispeciality tertiary care referral and teaching center by means of a printed questionnaire from anaesthesiology residents. A database was prepared and responses were analyzed. Results: Eighty resident doctors participated in the audit. Most (97.8% of the residents were sure of the presence of a defibrillator in the operation room (OR; 70% of postgraduates (PGs were aware of the location of the defibrillator in the OR as compared to 83.7% of the senior resident (SRs. Also, 32.1% residents routinely check the availability of a defibrillator. The working condition of the defibrillator was checked by 21.7% of the residents; 25.3% ensured delivery of the set charge. Further, 8.2% of residents ensured availability of both adult and paediatric paddles. About 27.8% of residents ensured the availability of appropriate conducting gel and 53.8% residents were of the opinion that the responsibility of checking the functioning and maintenance of the defibrillators lies with themselves. Some 22% thought that both doctors and technical staff should share the responsibility, while 19.5% opined that it should be the responsibility of the technical staff. Conclusion: All medical equipment is to be tested prior to initial use and periodically thereafter. An extensive, recurring training program, and continued attention to the training of clinical personnel is required to ensure that they are proficient in the operation and testing of specific defibrillator models in their work area. We conclude that apart from awareness of the use of the equipment we are using, its preuse testing is must. All resident doctors should be aware of the presence and adequate functioning of the

  2. Comorbidity burden is associated with poor psychological well-being and physical health status in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Kupper, Nina; Jordaens, Luc;

    2013-01-01

    Comorbidity burden has been linked to survival in patients with an implantable cardioverter-defibrillator (ICD), but no study has examined the influence on psychological well-being and health status. We examined the relationship between comorbidity burden and anxiety, depression, and health status...

  3. The distressed (Type D) personality in both patients and partners enhances the risk of emotional distress in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    van den Broek, Krista C; Versteeg, Henneke; Erdman, Ruud A M

    2011-01-01

    A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences emotional distress. This may be related to partner factors. We examined the impact of the personality of the partner (i.e., the distressed (Type D) personality) in combination with that of the patient on anxiety...

  4. Electrostriction Effects During Defibrillation

    CERN Document Server

    Fritz, Michelle M; Roth, Bradley J

    2011-01-01

    Background-The electric field applied to the heart during defibrillation causes mechanical forces (electrostriction), and as a result the heart deforms. This paper analyses the physical origin of the deformation, and how significant it is. Methods-We represent the heart as an anisotropic cylinder. This simple geometry allows us to obtain analytical solutions for the potential, current density, charge, stress, and strain. Results-Charge induced on the heart surface in the presence of the electric field results in forces that deform the heart. In addition, the anisotropy of cardiac tissue creates a charge density throughout the tissue volume, leading to body forces. These two forces cause the tissue to deform in a complicated manner, with the anisotropy suppressing radial displacements in favor of tangential ones. Quantitatively, the deformation of the tissue is small, although it may be significant when using some imaging techniques that require the measurement of small displacements. Conclusions-The anisotrop...

  5. [ICD diagnoses in university polyclinic naturopathy consultation].

    Science.gov (United States)

    Hentschel, C; Lindner, M; Brinkhaus, B; Nagel, M R; Hahn, E G; Kohnen, R

    1996-08-01

    In a special consulting office for complementary medicine, ambulatory patients interested in receiving adjuvant treatment with complementary medicine can obtain a relevant advice and critical information regarding non-evaluated therapies. Within the framework of a retrospective statistical analysis, the diagnosis documented over a period of 24 months in accordance with the 4-digit ICD code were evaluated. In particular patients with chronic and/or functional illnesses had additional treatment needs. The exponential growth in the numbers of patients during the course of the observation period illustrates the increasing importance of complementary medical measures. However, in view of the considerable political significance of the cost factor and the possible risks of the treatment, only properly evaluated complementary medical therapies should be employed.

  6. Interference of cardiac pacemaker and implantable cardioverter-defibrillator activity during electronic dental device use.

    Science.gov (United States)

    Roedig, Jason J; Shah, Jignesh; Elayi, Claude Samy; Miller, Craig S

    2010-05-01

    The authors conducted a study to determine if electromagnetic interference of cardiac pacemaker and implantable cardioverter-defibrillator (ICD) activity occurs during the operation of electronic dental devices. The authors tested nine electronic dental devices in vitro to assess their ability to interfere with the function of two pacemakers and two ICDs as determined by electrocardiographic telemetry. The pacing activity of both pacemakers and the dual-chamber ICD were inhibited during operation of the battery-operated composite curing light at between 2 and 10 centimeters from the generator or leads. The use of the ultrasonic scaler interfered with the pacing activity of the dual-chamber pacemaker at between 17 and 23 cm from the generator or leads, the single-chamber pacemaker at 15 cm from the generator or leads and both ICDs at 7 cm from the leads. The operation of the ultrasonic cleaning system interfered with the activity of the dual-chamber pacemaker at between 15 and 23 cm from the generator or leads, and of the single-chamber pacemaker at 12 cm. Operation of the electric toothbrush, electrosurgical unit, electric pulp tester, high- and low-speed handpieces, and an amalgamator did not alter pacing function. Select electronic dental devices interfere with pacemakers' and ICDs' sensing and pacing activity in vitro. Use of the ultrasonic scaler, ultrasonic cleaning system and battery-operated composite curing light may produce deleterious effects in patients who have pacemakers or ICDs.

  7. Specific and social phobias in ICD-11

    NARCIS (Netherlands)

    Emmelkamp, P.M.G.

    2012-01-01

    The purpose of this article is to discuss the current status of research with respect to specific phobias and social phobia as defined in the ICD-10 and DSM-IV, and to provide op- tions for their classification in the ICD-11. Both ICD-10 and DSM-IV identify three main classes of phobias: specific

  8. Specific and social phobias in ICD-11

    NARCIS (Netherlands)

    Emmelkamp, P.M.G.

    2012-01-01

    The purpose of this article is to discuss the current status of research with respect to specific phobias and social phobia as defined in the ICD-10 and DSM-IV, and to provide op- tions for their classification in the ICD-11. Both ICD-10 and DSM-IV identify three main classes of phobias: specific ph

  9. Safety and interaction of patients with implantable cardiac defibrillators driving a hybrid vehicle.

    Science.gov (United States)

    Tondato, Fernando; Bazzell, Jane; Schwartz, Linda; Mc Donald, Bruce W; Fisher, Robert; Anderson, S Shawn; Galindo, Arcenio; Dueck, Amylou C; Scott, Luis R

    2017-01-15

    Electromagnetic interference (EMI) can affect the function of implantable cardioverter defibrillators (ICD). Hybrid electric vehicles (HEV) have increased popularity and are a potential source of EMI. Little is known about the in vivo effects of EMI generated by HEV on ICD. This study evaluated the in vivo interaction between EMI generated by HEV with ICD. Thirty patients (73±9 y/o; 80% male) with stable ICD function were exposed to EMI generated by a Toyota Prius Hybrid®. The vehicle was lifted above the ground, allowing safe changes in engine rotation and consequent variations in electromagnetic emission. EMI was measured (NARDA STS® model EHP-50C) and expressed in A/m (magnetic), Volts/m (electrical), and Hertz (frequency). Six positions were evaluated: driver, front passenger, right and left back seats, outside, at the back and front of the car. Each position was evaluated at idle, 30 mph, 60 mph and variable speeds (acceleration-deceleration-brake). All ICD devices were continuously monitored during the study. The levels of EMI generated were low (highest mean levels: 2.09A/m at right back seat at 30 mph; and 3.5V/m at driver seat at variable speeds). No episode of oversensing or inadvertent change in ICD programming was observed. It is safe for patients with ICD to interact with HEV. This is the first study to address this issue using an in vivo model. Further studies are necessary to evaluate the interaction of different models of HEV or electric engine with ICD or unipolar pacemakers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Electromagnetic Interference from Swimming Pool Generator Current Causing Inappropriate ICD Discharges

    Directory of Open Access Journals (Sweden)

    Edward Samuel Roberto

    2017-01-01

    Full Text Available Electromagnetic interference (EMI includes any electromagnetic field signal that can be detected by device circuitry, with potentially serious consequences: incorrect sensing, pacing, device mode switching, and defibrillation. This is a unique case of extracardiac EMI by alternating current leakage from a submerged motor used to recycle chlorinated water, resulting in false rhythm detection and inappropriate ICD discharge. A 31-year-old female with arrhythmogenic right ventricular cardiomyopathy and Medtronic dual-chamber ICD placement presented after several inappropriate ICD shocks at the public swimming pool. Patient had never received prior shocks and device was appropriate at all regular follow-ups. Intracardiac electrograms revealed unique, high-frequency signals at exactly 120 msec suggestive of EMI from a strong external source of alternating current. Electrical artifact was incorrectly sensed as a ventricular arrhythmia which resulted in discharge. ICD parameters including sensing, pacing thresholds, and impedance were all normal suggesting against device malfunction. With device failure and intracardiac sources excluded, EMI was therefore strongly suspected. Avoidance of EMI source brought complete resolution with no further inappropriate shocks. After exclusion of intracardiac interference, device malfunction, and abnormal settings, extracardiac etiologies such as EMI must be thoughtfully considered and excluded. Elimination of inappropriate shocks is to “first, do no harm.”

  11. Impact of shocks on mortality in patients with ischemic or dilated cardiomyopathy and defibrillators implanted for primary prevention.

    Directory of Open Access Journals (Sweden)

    Florian Streitner

    Full Text Available BACKGROUND: Emerging interest is seen in the paradox of defibrillator shocks for ventricular tachyarrhythmia and increased mortality risk. Particularly in patients with dilated cardiomyopathy (DCM, the prognostic importance of shocks is unclear. The purpose of this study was to compare the outcome after shocks in patients with ischemic cardiomyopathy (ICM or DCM and defibrillators (ICD implanted for primary prevention. METHODS AND RESULTS: Data of 561 patients were analyzed (mean age 68.6±10.6 years, mean left ventricular ejection fraction 28.6±7.3%. During a median follow-up of 49.3 months, occurrence of device therapies and all-cause mortality were recorded. 74 out of 561 patients (13.2% experienced ≥1 appropriate and 51 out of 561 patients (9.1% ≥1 inappropriate shock. All-cause mortality was 24.2% (136 out of 561 subjects. Appropriate shock was associated with a trend to higher mortality in the overall patient population (HR 1.48, 95% CI 0.96-2.28, log rank p = 0.072. The effect was significant in ICM patients (HR 1.61, 95% CI 1.00-2.59, log rank p = 0.049 but not in DCM patients (HR 1.03, 95% CI 0.36-2.96, log rank p = 0.96. Appropriate shocks occurring before the median follow-up revealed a much stronger impact on mortality (HR for the overall patient population 2.12, 95% CI 1.24-3.63, p = 0.005. The effect was driven by ICM patients (HR 2.48, 95% CI 1.41-4.37, p = 0.001, as appropriate shocks again did not influence survival of DCM patients (HR 0.63, 95% CI 0.083-4.75, p = 0.65. Appropriate shocks occurring after the median follow-up and inappropriate shocks occurring at any time revealed no impact on survival in any of the groups (p = ns. CONCLUSION: Appropriate shocks are associated with reduced survival in patients with ICM but not in patients with DCM and ICDs implanted for primary prevention. Furthermore, the negative effect of appropriate shocks on survival in ICM patients is only evident within the

  12. Conducting Retrospective Ontological Clinical Trials in ICD-9-CM in the Age of ICD-10-CM

    Science.gov (United States)

    Venepalli, Neeta K; Shergill, Ardaman; Dorestani, Parvaneh; Boyd, Andrew D

    2014-01-01

    OBJECTIVE To quantify the impact of International Classification of Disease 10th Revision Clinical Modification (ICD-10-CM) transition in cancer clinical trials by comparing coding accuracy and data discontinuity in backward ICD-10-CM to ICD-9-CM mapping via two tools, and to develop a standard ICD-9-CM and ICD-10-CM bridging methodology for retrospective analyses. BACKGROUND While the transition to ICD-10-CM has been delayed until October 2015, its impact on cancer-related studies utilizing ICD-9-CM diagnoses has been inadequately explored. MATERIALS AND METHODS Three high impact journals with broad national and international readerships were reviewed for cancer-related studies utilizing ICD-9-CM diagnoses codes in study design, methods, or results. Forward ICD-9-CM to ICD-10-CM mapping was performing using a translational methodology with the Motif web portal ICD-9-CM conversion tool. Backward mapping from ICD-10-CM to ICD-9-CM was performed using both Centers for Medicare and Medicaid Services (CMS) general equivalence mappings (GEMs) files and the Motif web portal tool. Generated ICD-9-CM codes were compared with the original ICD-9-CM codes to assess data accuracy and discontinuity. RESULTS While both methods yielded additional ICD-9-CM codes, the CMS GEMs method provided incomplete coverage with 16 of the original ICD-9-CM codes missing, whereas the Motif web portal method provided complete coverage. Of these 16 codes, 12 ICD-9-CM codes were present in 2010 Illinois Medicaid data, and accounted for 0.52% of patient encounters and 0.35% of total Medicaid reimbursements. Extraneous ICD-9-CM codes from both methods (Centers for Medicare and Medicaid Services general equivalent mapping [CMS GEMs, n = 161; Motif web portal, n = 246]) in excess of original ICD-9-CM codes accounted for 2.1% and 2.3% of total patient encounters and 3.4% and 4.1% of total Medicaid reimbursements from the 2010 Illinois Medicare database. DISCUSSION Longitudinal data analyses post-ICD-10

  13. Educational and psychological interventions to improve outcomes for recipients of implantable cardioverter defibrillators and their families: a scientific statement from the American Heart Association.

    Science.gov (United States)

    Dunbar, Sandra B; Dougherty, Cynthia M; Sears, Samuel F; Carroll, Diane L; Goldstein, Nathan E; Mark, Daniel B; McDaniel, George; Pressler, Susan J; Schron, Eleanor; Wang, Paul; Zeigler, Vicki L

    2012-10-23

    Significant mortality benefits have been documented in recipients of implantable cardioverter defibrillators (ICDs); however, the psychosocial distress created by the underlying arrhythmia and its potential treatments in patients and family members may be underappreciated by clinical care teams. The disentanglement of cardiac disease and device-related concerns is difficult. The majority of ICD patients and families successfully adjust to the ICD, but optimal care pathways may require additional psychosocial attention to all ICD patients and particularly those experiencing psychosocial distress. This state-of-the-science report was developed on the basis of an analysis and critique of existing science to (1) describe the psychological and quality-of-life outcomes after receipt of an ICD and describe related factors, such as patient characteristics; (2) describe the concerns and educational/informational needs of ICD patients and their family members; (3) outline the evidence that supports interventions for improving educational and psychological outcomes for ICD patients; (4) provide recommendations for clinical approaches for improving patient outcomes; and (5) identify priorities for future research in this area. The ultimate goal of this statement is to improve the precision of identification and care of psychosocial distress in ICD patients to maximize the derived benefit of the ICD.

  14. Psychological effects of implantable cardioverter defibrillator shocks. A review of study methods

    Science.gov (United States)

    Manzoni, Gian Mauro; Castelnuovo, Gianluca; Compare, Angelo; Pagnini, Francesco; Essebag, Vidal; Proietti, Riccardo

    2015-01-01

    Background: The implantable cardioverter defibrillator (ICD) saves lives but clinical experience suggests that it may have detrimental effects on mental health. The ICD shock has been largely blamed as the main offender but empirical evidence is not consistent, perhaps because of methodological differences across studies. Objective: To appraise methodologies of studies that assessed the psychological effects of ICD shock and explore associations between methods and results. Data Sources: A comprehensive search of English articles that were published between 1980 and 30 June 2013 was applied to the following electronic databases: PubMed, EMBASE, NHS HTA database, PsycINFO, Sciencedirect and CINAHL. Review Methods: Only studies testing the effects of ICD shock on psychological and quality of life outcomes were included. Data were extracted according to a PICOS pre-defined sheet including methods and study quality indicators. Results: Fifty-four observational studies and six randomized controlled trials met the inclusion criteria. Multiple differences in methods that were used to test the psychological effects of ICD shock were found across them. No significant association with results was observed. Conclusions: Methodological heterogeneity of study methods is too wide and limits any quantitative attempt to account for the mixed findings. Well-built and standardized research is urgently needed. PMID:25698991

  15. Position paper for management of elderly patients with pacemakers and implantable cardiac defibrillators Groupe de rythmologie et stimulation cardiaque de la Société française de cardiologie et Société française de gériatrie et gérontologie.

    Science.gov (United States)

    Fauchier, Laurent; Alonso, Christine; Anselme, Frédéric; Blangy, Hugues; Bordachar, Pierre; Boveda, Serge; Clementy, Nicolas; Defaye, Pascal; Deharo, Jean-Claude; Friocourt, Patrick; Gras, Daniel; Halimi, Franck; Klug, Didier; Mansourati, Jacques; Obadia, Benjamin; Pasquié, Jean-Luc; Pavin, Dominique; Sadoul, Nicolas; Taieb, Jérôme; Piot, Olivier; Hanon, Olivier

    2016-09-01

    Despite the increasingly high rate of implantation of pacemakers (PM) and cardioverter-defibrillators (ICD) in elderly patients, data supporting their clinical and cost-effectiveness in this age stratum are ambiguous and contradictory. We reviewed the data regarding the applicability, safety, and effectiveness of the conventional pacing, ICD and cardiac resynchronization therapy (CRT) in elderly patients. Although peri-procedural risk may be slightly higher in the elderly, the procedure of implantation of PMs and ICDs is still relatively safe in this age group. In older patients with sinus node disease, a general consensus is that dual chamber pacing, along with the programming of an algorithm to minimise ventricular pacing is preferred. In very old patients presenting with intermittent or suspected AV block, VVI pacing may be appropriate. In terms of correcting potentially life-threatening arrhythmias, the effectiveness of ICD therapy is comparable in older and younger individuals. However, the assumption of persistent ICD benefit in the elderly population is questionable, as any advantage of the device on arrhythmic death may be attenuated by a higher total non-arrhythmic mortality. While septuagenarians and octogenarians have higher annual all-cause mortality rates, ICD therapy may remain effective in selected patients at high risk of arrhythmic death and with minimum comorbidities despite advanced age. ICD implantation among the elderly, as a group, may not be cost-effective, but the procedure may reach cost-effectiveness in those expected to live >5-7 years after implantation. The elderly patients usually experience a significant functional improvement after CRT, similar to that observed in middle-aged patients. Management of CRT non responders remains globally the same, while considering a less aggressive approach in terms of re interventions (revision of LV lead placement, addition of a RV or LV lead, LV endocardial pacing configuration). Overall, age

  16. Position paper for management of elderly patients with pacemakers and implantable cardiac defibrillators: Groupe de Rythmologie et Stimulation Cardiaque de la Société Française de Cardiologie and Société Française de Gériatrie et Gérontologie.

    Science.gov (United States)

    Fauchier, Laurent; Alonso, Christine; Anselme, Frederic; Blangy, Hugues; Bordachar, Pierre; Boveda, Serge; Clementy, Nicolas; Defaye, Pascal; Deharo, Jean-Claude; Friocourt, Patrick; Gras, Daniel; Halimi, Franck; Klug, Didier; Mansourati, Jacques; Obadia, Benjamin; Pasquié, Jean-Luc; Pavin, Dominique; Sadoul, Nicolas; Taieb, Jerome; Piot, Olivier; Hanon, Olivier

    2016-10-01

    Despite the increasingly high rate of implantation of pacemakers (PMs) and implantable cardioverter defibrillators (ICDs) in elderly patients, data supporting their clinical and cost-effectiveness in this age stratum are ambiguous and contradictory. We reviewed the data regarding the applicability, safety and effectiveness of conventional pacing, ICDs and cardiac resynchronization therapy (CRT) in elderly patients. Although periprocedural risk may be slightly higher in the elderly, the implantation procedure for PMs and ICDs is still relatively safe in this age group. In older patients with sinus node disease, the general consensus is that DDD pacing with the programming of an algorithm to minimize ventricular pacing is preferred. In very old patients presenting with intermittent or suspected atrioventricular block, VVI pacing may be appropriate. In terms of correcting potentially life-threatening arrhythmias, the effectiveness of ICD therapy is similar in older and younger individuals. However, the assumption of persistent ICD benefit in the elderly population is questionable, as any advantageous effect of the device on arrhythmic death may be attenuated by higher total non-arrhythmic mortality. While septuagenarians and octogenarians have higher annual all-cause mortality rates, ICD therapy may remain effective in selected patients at high risk of arrhythmic death and with minimum comorbidities despite advanced age. ICD implantation among the elderly, as a group, may not be cost-effective, but the procedure may reach cost-effectiveness in those expected to live more than 5-7years after implantation. Elderly patients usually experience significant functional improvement after CRT, similar to that observed in middle-aged patients. Management of CRT non-responders remains globally the same, while considering a less aggressive approach in terms of reinterventions (revision of left ventricular [LV] lead placement, addition of a right ventricular or LV lead, LV

  17. DDD-ICD: discrimination of supraventricular tachyarrhythmias Discriminação de taquiarritmias supraventriculares

    Directory of Open Access Journals (Sweden)

    Amiran R. REVISHVILI

    1999-01-01

    Full Text Available Background: Dual Chamber Implantable Cardioverter Defibrillator (ICD in addition to providing hemodynamically improved bradycardia support can also reduce the incidence of inappropriate ventricular shocks owing to episodes of Supraventricular Tachycardia (SVT, with reported incidence of up to 41% of patients. An atrio-ventricular (AV discrimination algorithm is needed in dual chamber implantable cardioverter-defibrillators (ICD to avoid these inappropriate shocks. Methods: An AV discrimination algorithm, SMART DetectionTM, has been developed to differentiate between episodes of ventricular tachycardia (VT and SVT. It relies on the concept that the chamber with the higher rate is the origin of the tachycardia. The ventricular rate stability criterion is also used to detect concurrent VT during an episode of SVT. Other parameters used in the discrimination algorithm are: atrial and ventricular rhythm multiplicity, P-R regularity, sudden onset. The SMART DetectionTM algorithm has been implemented in the Biotronik Phylax® AV dual chamber ICD. The original SMART DetectionTM has been improved recently with the addition of active detection in the case of 1:1 AV conduction. Results: 10 patients were implanted with Phylax® AV's at the Bakoulev Institute. Analyses of stored dual chamber intracardiac electrogram (IEGM indicate that all episodes of VTs and Ventricular Fibrillations (VF were terminated following appropriate therapies. No episode of Atrial Flutter (Afl or Atrial Fibrillation (AF was treated even though the majority of patients have a history of SVTs. In one patient, an episode of Sinus Tachycardia (ST was inappropriately treated. Increasing the sudden onset criterion, which is used only in the case of stable 1:1 rhythms, was sufficient to prevent recurrence of inappropriate therapy. To avoid the necessity of setting the, not very reliable, sudden onset criterion an active detection procedure was developed. Isolated Premature Ventricular

  18. Dental management of a patient fitted with subcutaneous Implantable Cardioverter Defibrillator device and concomitant warfarin treatment

    Directory of Open Access Journals (Sweden)

    Altaf Hussain Shah

    2015-07-01

    This article presents the dental management of a 60 year-old person with an ICD and concomitant anticoagulant therapy. The patient was on multiple medications and was treated for a grossly neglected mouth with multiple carious root stumps. This case report outlines the important issues in managing patients fitted with an ICD device and at a risk of sudden cardiac death.

  19. Depression and Associated Factors in Patients with Implantable Cardioverter-Defibrillators

    Directory of Open Access Journals (Sweden)

    Maryam Moshkani Farahani

    2017-01-01

    Full Text Available  Background: Psychological problems such as depression constitute a dilemma that patients with the implantable cardioverter-defibrillator (ICD usually encounter and may impact their quality of life. The purpose of this study was to evaluate the prevalence of depression among adults with the ICD and the relationship between depression and associated factors.   Methods: Totally, 115 individuals with the ICD participated in this cross-sectional study in Tehran, Iran, and depression and other related risk factors were evaluated in them. Two questionnaires, one for demographic characteristics and the Beck Depression Inventory, were applied for data acquisition. The data were analyzed, and the factors associated with depression in the patients with the ICD were assessed.    Results: The mean age of the study population was 59.85 ± 11.46 years. Males comprised 88 (76.5% and females 27 (23.5% of the patients. The multivariate analysis on the 115 patients revealed that frequency of ICD shocks (OR = 1.08, 95%CI: 1.02 - 1.10, male sex (OR = 2.28, 95%CI: 1.027 - 5.07, more hospital admissions (OR = 1.19, 95%CI: 1.11 - 1.25, smoking cessation (OR = 9.8, 95%CI: 4.48 - 20.07, presence of ICD shocks (OR = 4.5, 95%CI: 2.45 - 7.38, dyslipidemia (OR = 2.8, 95%CI: 1.22 - 4.95, and family history of depression (OR = 6.4, 95%CI: 3.0 - 13.46 were significantly and independently associated with the Beck score classifications.    Conclusion: These findings suggest that a poor psychosocial outcome in patients with the ICD may occur as a result of a variety of associated factors, most of which are predictable and preventable. 

  20. Use of Automated External Defibrillators

    Energy Technology Data Exchange (ETDEWEB)

    Gregory K Christensen

    2009-02-01

    In an effort to improve survival from cardiac arrest, the American Heart Association (AHA) has promoted the Chain of Survival concept, describing a sequence of prehospital steps that result in improved survival after sudden cardiac arrest. These interventions include immediate deployment of emergency medical services, prompt cardiopulmonary resuscitation, early defibrillation when indicated, and early initiation of advanced medical care. Early defibrillation has emerged as the most important intervention with survival decreasing by 10% with each minute of delay in defibrillation. Ventricular Fibrillation (VF) is a condition in which there is uncoordinated contraction of the heart cardiac muscle of the ventricles in the heart, making them tremble rather than contract properly. VF is a medical emergency and if the arrhythmia continues for more than a few seconds, blood circulation will cease, and death can occur in a matter of minutes. During VF, contractions of the heart are not synchronized, blood flow ceases, organs begin to fail from oxygen deprivation and within 10 minutes, death will occur. When VF occurs, the victim must be defibrillated in order to establish the heart’s normal rhythm. On average, the wait for an ambulance in populated areas of the United States is about 11 minutes. In view of these facts, the EFCOG Electrical Safety Task Group initiated this review to evaluate the potential value of deployment and use of automated external defibrillators (AEDs) for treatment of SCA victims. This evaluation indicates the long term survival benefit to victims of SCA is high if treated with CPR plus defibrillation within the first 3-5 minutes after collapse. According to the American Heart Association (AHA), survival rates as high as 74% are possible if treatment and defibrillation is performed in the first 3 minutes. In contrast survival rates are only 5% where no AED programs have been established to provide prompt CPR and defibrillation. ["CPR statistics

  1. Relation between emotional distress and heart rate variability in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Pedersen, Susanne S.; Theuns, Dominic A M J

    2014-01-01

    We investigated the relationship between Type D personality, depression, and anxiety, and heart rate variability (HRV) in 64 patients with an implantable cardioverter-defibrillator (ICD). HRV was obtained via 24-h Holter monitoring, and 24-h, 30-min daytime rest and 30-min nighttime sleep HRV were...... for depression (lower RMSSD: p = .10; lower pNN50: p = .09). During daytime rest, similar results were found for anxiety and depression. During sleep, only noteworthy adjusted associations were found for depression (lower root mean square of successive differences in NN intervals [RMSSD]: p = .06; lower pNN50: p...

  2. SU-E-T-169: Characterization of Pacemaker/ICD Dose in SAVI HDR Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kalavagunta, C; Lasio, G; Yi, B; Zhou, J; Lin, M [Univ. of Maryland School Of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: It is important to estimate dose to pacemaker (PM)/Implantable Cardioverter Defibrillator (ICD) before undertaking Accelerated Partial Breast Treatment using High Dose Rate (HDR) brachytherapy. Kim et al. have reported HDR PM/ICD dose using a single-source balloon applicator. To the authors knowledge, there have so far not been any published PM/ICD dosimetry literature for the Strut Adjusted Volume Implant (SAVI, Cianna Medical, Aliso Viejo, CA). This study aims to fill this gap by generating a dose look up table (LUT) to predict maximum dose to the PM/ICD in SAVI HDR brachytherapy. Methods: CT scans for 3D dosimetric planning were acquired for four SAVI applicators (6−1-mini, 6−1, 8−1 and 10−1) expanded to their maximum diameter in air. The CT datasets were imported into the Elekta Oncentra TPS for planning and each applicator was digitized in a multiplanar reconstruction window. A dose of 340 cGy was prescribed to the surface of a 1 cm expansion of the SAVI applicator cavity. Cartesian coordinates of the digitized applicator were determined in the treatment leading to the generation of a dose distribution and corresponding distance-dose prediction look up table (LUT) for distances from 2 to 15 cm (6-mini) and 2 to 20 cm (10–1).The deviation between the LUT doses and the dose to the cardiac device in a clinical case was evaluated. Results: Distance-dose look up table were compared to clinical SAVI plan and the discrepancy between the max dose predicted by the LUT and the clinical plan was found to be in the range (−0.44%, 0.74%) of the prescription dose. Conclusion: The distance-dose look up tables for SAVI applicators can be used to estimate the maximum dose to the ICD/PM, with a potential usefulness for quick assessment of dose to the cardiac device prior to applicator placement.

  3. Conventional and right-sided screening for subcutaneous ICD in a population with congenital heart disease at high risk of sudden cardiac death.

    Science.gov (United States)

    Alonso, Pau; Osca, Joaquín; Rueda, Joaquín; Cano, Oscar; Pimenta, Pedro; Andres, Ana; Sancho, María José; Martinez, Luis

    2017-05-15

    Information regarding suitability for subcutaneous defibrillator (sICD) implantation in tetralogy of Fallot (ToF) and systemic right ventricle is scarce and needs to be further explored. The main objective of our study was to determine the proportion of patients with ToF and systemic right ventricle eligible for sICD with both, standard and right-sided screening methods. Secondary objectives were: (i) to study sICD eligibility specifically in patients at high risk of sudden cardiac death, (ii) to identify independent predictors for sICD eligibility, and (iii) to compare the proportion of eligible patients in a nonselected ICD population. We recruited 102 patients with ToF, 33 with systemic right ventricle, and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left-arm and right-arm electrodes 1 cm right lateral of the xiphoid midline. The Boston Scientific ECG screening tool was utilized. In high-risk patients with ToF, eligibility was higher with right-sided screening in comparison with standard screening (61% vs. 44%; p = .018). Eligibility in high-risk right ventricle population was identical with both screening methods (77%, p = ns). The only independent predictor for sICD eligibility was QRS duration. In high-risk patients with ToF, right-sided implantation of the sICD could be an alternative to a conventional ICD. In patients with a systemic right ventricle, implantation of a sICD is an alternative to a conventional sICD. © 2017 Wiley Periodicals, Inc.

  4. [The development of the ICD-11].

    Science.gov (United States)

    2011-01-01

    The ICD-10 will have been used for approximately twenty years by the time the new revision of the ICD (ICD-11) is completed, and the revision process is being implemented. Accordingly, the WHO has organized groups of experts designated to deal with issues in each field, and the International Advisory Group for the Revision of ICD-10 Mental and Behavioral Disorders has been launched for the field of psychiatry. Regarding the revision, this group is responsible for ultimate decision-making in establishing a framework for the new version. We reported processes of the ICD-11 by the above mentioned group and its coordinating groups and working groups. In addition, we reported the WHO-WPA Survey which was distributed to 500 members of the Japanese Society for Psychiatry and Neurology.

  5. Slow ventricular tachycardia in a 91-year-old man with implantable cardioverter-defibrillator and acute respiratory failure.

    Science.gov (United States)

    Vargas, Nicola; Tibullo, Loredana; Landi, Cesare A E; Carifi, Giovanni; Landi, Emanuela; Salsano, Elisa; Di Grezia, Francesco; Candelmo, Fiore

    2017-08-01

    Slow ventricular tachycardia (VT) in patients with devices such as an implantable cardioverter - defibrillator (ICD) is more common than in the rest of the population. The incidence in elderly patients with an ICD remains largely unknown. In younger patients, slow VT is generally asymptomatic or associated with limited clinical relevance. It may be efficiently and safely terminated by anti-tachycardia pacing. We present a case of slow VT in a 91-year-old man with ICD with type 1 acute respiratory failure and drowsiness. Very elderly patients who have poor cardiac reserve and minor deterioration in cardiac function can face serious consequences such as ventricular fibrillation, cardiac arrest, and sudden cardiac death. The persistent ventricular rhythm may have a deleterious effect on their haemodynamic status, with potential aggravation of symptoms of heart failure and further impairment of ventricular function. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Venous thromboembolism in patients with implantable cardioverter-defibrillators

    DEFF Research Database (Denmark)

    Pedersen, Susanne Bendesgaard; Hjortshøj, Søren Pihlkjær; Bøtker, Hans Erik;

    2016-01-01

    , overall and according to gender, age, Charlson Comorbidity Index score (no, moderate, or severe comorbidity), prior pacemaker or cardiac resynchronization therapy (CRT-D) implantation, and ICD type (single-chamber, dual-chamber, or CRT-D). We computed the risk of VTE within 3 months and 5 years...

  7. The Power of Exercise-Induced T-wave Alternans to Predict Ventricular Arrhythmias in Patients with Implanted Cardiac Defibrillator

    Directory of Open Access Journals (Sweden)

    Laura Burattini

    2013-01-01

    Full Text Available The power of exercise-induced T-wave alternans (TWA to predict the occurrence of ventricular arrhythmias was evaluated in 67 patients with an implanted cardiac defibrillator (ICD. During the 4-year follow-up, electrocardiographic (ECG tracings were recorded in a bicycle ergometer test with increasing workload ranging from zero (NoWL to the patient's maximal capacity (MaxWL. After the follow-up, patients were classified as either ICD_Cases (n = 29, if developed ventricular tachycardia/fibrillation, or ICD_Controls (n = 38. TWA was quantified using our heart-rate adaptive match filter. Compared to NoWL, MaxWL was characterized by faster heart rates and higher TWA in both ICD_Cases (12-18 μ V vs. 20-39 μ V; P < 0.05 and ICD_Controls (9-15 μ V vs. 20-32 μ V; P < 0.05. Still, TWA was able to discriminate the two ICD groups during NoWL (sensitivity = 59-83%, specificity = 53-84% but not MaxWL (sensitivity = 55-69%, specificity = 39-74%. Thus, this retrospective observational case-control study suggests that TWA's predictive power for the occurrence of ventricular arrhythmias could increase at low heart rates.

  8. Pacemakers and implantable cardioverter defibrillators, unknown to chest radiography: Review, complications and systematic reading

    Energy Technology Data Exchange (ETDEWEB)

    Alandete Germán, Salvador Pascual, E-mail: salaiger@gmail.com; Isarria Vidal, Santiago, E-mail: isarria@comv.es; Domingo Montañana, María Luisa, E-mail: domingo.luimon@gmail.com; De la vía Oraá, Esperanza, E-mail: esviao82@gmail.com; Vilar Samper, José, E-mail: vilarsamper@gmail.com

    2015-03-15

    Highlights: •Radiologists have an important function in the evaluation of these devices. •We revise their radiological appearances and possible complications. •The knowledge in normal aspects and complications is important for radiologist. •To ensure an accurate reading of the chest x-ray, we present a systematic approach. -- Abstract: Chest X-ray is the imaging technique of choice for an initial study of pacemakers and implantable cardio-defibrillators (ICD). Radiologists have an important role in the evaluation of its initial placement and in the assessment during its follow-up. For this reason, it is necessary to know not only the different existing devices and its components but also the reasons of malfunction or possible complications. The purpose of this article is to do a systematic review of the different types of pacemakers and ICD. We review their usual radiological appearances, the possible complications which might take place and its causes of malfunctioning.

  9. Successful use of wearable cardioverter defibrillator in a patient with dextrocardia and persistent left superior vena cava.

    Science.gov (United States)

    Wan, Chingping; Oren, Jess W; Szymkiewicz, Steven J

    2013-09-01

    Congenital disorders, such as dextrocardia and persistent left superior vena cava, are rare. However, their presence is often associated with other cardiac anomalies, and may lead to lethal ventricular tachyarrhythmias, which result in sudden cardiac death. Treating patients with these disorders can present a challenge to clinicians, as it may cause technical difficulties during interventional procedures, and more often, altered defibrillation techniques in a setting of prehospital sudden cardiac arrest. This report describes the first case of successful defibrillation therapy delivered by the wearable cardioverter defibrillator to a patient with dextrocardia and persistent left superior vena cava during a ventricular tachycardia arrest.

  10. Poor perceived social support in implantable cardioverter defibrillator (ICD) patients and their partners

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Spinder, Helle; Erdman, Ruud A M;

    2009-01-01

    Social support is a known buffer of psychological distress and has also been shown to influence adverse medical outcomes.......Social support is a known buffer of psychological distress and has also been shown to influence adverse medical outcomes....

  11. Preventing tomorrow's sudden cardiac death today: dissemination of effective therapies for sudden cardiac death prevention.

    Science.gov (United States)

    Al-Khatib, Sana M; Sanders, Gillian D; Carlson, Mark; Cicic, Aida; Curtis, Anne; Fonarow, Gregg C; Groeneveld, Peter W; Hayes, David; Heidenreich, Paul; Mark, Daniel; Peterson, Eric; Prystowsky, Eric N; Sager, Philip; Salive, Marcel E; Thomas, Kevin; Yancy, Clyde W; Zareba, Wojciech; Zipes, Douglas

    2008-10-01

    Because the burden of sudden cardiac death (SCD) is substantial, it is important to use all guideline-driven therapies to prevent SCD. Among those therapies is the implantable cardioverter defibrillator (ICD). When indicated, ICD use is beneficial and cost-effective. Unfortunately, studies suggest that most patients who have indications for this therapy for primary or secondary prevention of SCD are not receiving it. To explore potential reasons for this underuse and to propose potential facilitators for ICD dissemination, the Duke Center for the Prevention of SCD at the Duke Clinical Research Institute (Durham, NC) organized a think tank meeting of experts on this issue. The meeting took place on December 12 and 13, 2007, and it included representatives of clinical cardiology, cardiac electrophysiology, general internal medicine, economics, health policy, the US Food and Drug Administration, the Centers for Medicare and Medicaid Services, the Agency for Health care Research and Quality, and the device and pharmaceutical industry. Although the meeting was funded by industry participants, this article summarizing the presentations and discussions that occurred at the meeting presents the expert opinion of the authors.

  12. Investigation of the Utility of the Audible Alert in Recent Generation Medtronic Implantable Cardioverter Defibrillators.

    Science.gov (United States)

    Manandhar, Meryna; Nemirovsky, Dmitry; Feigenblum, David Y; Simons, Grant R

    2016-12-01

    Medtronic implantable cardioverter defibrillators (ICDs; Medtronic Inc., Mounds View, MN, USA) are equipped with Patient Alert™, a feature in which the ICD generator emits a series of audible tones to notify patients of possible system malfunction. A prior study of this issue revealed that only 50% of patients with older Medtronic devices were able to hear alerts. More recently, Medtronic has incorporated modifications to the alert. Therefore, we studied how frequently alert tones emitted by the current generation of Medtronic ICDs are audible by patients. A series of patients were evaluated in an outpatient ICD clinic. Alert tones were demonstrated using a device programmer in a quiet room and in the presence of low-level background noise. Patients reported whether they heard the tones, and they completed questionnaires regarding the tones. The total sample size was 100 patients, 81 male, who ranged from 29 years to 94 years of age (mean age 72.1 ± 11.8). Among the study subjects, 46% were older than 75 years, 41% were between 55 years and 75 years, and 13% were younger than 55 years. In the absence of background noise, 94% of patients were able to hear both alerts, 1% heard only one alert, and 5% heard neither. In the presence of background noise, 88% of patients heard both the alerts, 7% heard only one alert, and 5% heard neither alerts. Our results demonstrate that alert tones in recent generation Medtronic ICDs have improved audibility, compared to prior published data, among a large outpatient ICD population. © 2016 Wiley Periodicals, Inc.

  13. Management of radiation oncology patients with a pacemaker or ICD: A new comprehensive practical guideline in The Netherlands

    Directory of Open Access Journals (Sweden)

    Hurkmans Coen W

    2012-11-01

    Full Text Available Abstract Current clinical guidelines for the management of radiotherapy patients having either a pacemaker or implantable cardioverter defibrillator (both CIEDs: Cardiac Implantable Electronic Devices do not cover modern radiotherapy techniques and do not take the patient’s perspective into account. Available data on the frequency and cause of CIED failure during radiation therapy are limited and do not converge. The Dutch Society of Radiotherapy and Oncology (NVRO initiated a multidisciplinary task group consisting of clinical physicists, cardiologists, radiation oncologists, pacemaker and ICD technologists to develop evidence based consensus guidelines for the management of CIED patients. CIED patients receiving radiotherapy should be categorised based on the chance of device failure and the clinical consequences in case of failure. Although there is no clear cut-off point nor a clear linear relationship, in general, chances of device failure increase with increasing doses. Clinical consequences of device failures like loss of pacing, carry the most risks in pacing dependent patients. Cumulative dose and pacing dependency have been combined to categorise patients into low, medium and high risk groups. Patients receiving a dose of less than 2 Gy to their CIED are categorised as low risk, unless pacing dependent since then they are medium risk. Between 2 and 10 Gy, all patients are categorised as medium risk, while above 10 Gy every patient is categorised as high risk. Measures to secure patient safety are described for each category. This guideline for the management of CIED patients receiving radiotherapy takes into account modern radiotherapy techniques, CIED technology, the patients’ perspective and the practical aspects necessary for the safe management of these patients. The guideline is implemented in The Netherlands in 2012 and is expected to find clinical acceptance outside The Netherlands as well.

  14. Reliability of clinical ICD-10 schizophrenia diagnoses

    DEFF Research Database (Denmark)

    Jakobsen, Klaus D; Frederiksen, Julie N; Hansen, Thomas

    2005-01-01

    Concern has been expressed as to the reliability of clinical ICD-10 diagnosis of schizophrenia. This study was designed to assess the diagnostic reliability of the clinical ICD-10 diagnosis of schizophrenia in a random sample of Danish in- and outpatients with a history of psychosis. A sample...... value (87%) of ICD-10 schizophrenia and an overall good agreement between clinical and OPCRIT-derived diagnoses (kappa=0.60). An even higher positive predictive value was obtained when diagnoses were amalgamated into a diagnostic entity of schizophrenia-spectrum disorders (98%). Near perfect agreement...... was seen between OPCRIT-derived ICD-10 and DSM-IV diagnoses (kappa=0.87). Thus, this study demonstrates high reliability of the clinical diagnosis of schizophrenia and even more so of the diagnosis of schizophrenia-spectrum disorder....

  15. Enhanced risk profiling of implanted defibrillator shocks with circulating SCN5A mRNA splicing variants: a pilot trial.

    Science.gov (United States)

    Gao, Ge; Brahmanandam, Vikram; Raicu, Mihai; Gu, Lianzhi; Zhou, Li; Kasturirangan, Srinivasan; Shah, Anish; Negi, Smita I; Wood, Melissa R; Desai, Ankit A; Tatooles, Antone; Schwartz, Alan; Dudley, Samuel C

    2014-06-03

    The aim of this study was to determine the association of SCN5A cardiac sodium (Na(+)) channel mRNA splice variants in white blood cells (WBCs) with risk of arrhythmias in heart failure (HF). HF is associated with upregulation of two cardiac SCN5A mRNA splice variants that encode prematurely truncated, nonfunctional Na(+) channels. Because circulating WBCs demonstrate similar SCN5A splicing patterns, we hypothesized that these WBC-derived splice variants might further stratify patients with HF who are at risk for arrhythmias. Simultaneously obtained myocardial core samples and WBCs were compared for SCN5A variants C (VC) and D (VD). Circulating variant levels were compared among patients with HF, divided into three groups: HF without an implantable cardioverter-defibrillator (ICD), HF with an ICD without appropriate intervention, and HF with an ICD with appropriate intervention. Myocardial tissue-derived SCN5A variant expression levels strongly correlated with circulating WBC samples for both VC and VD variants (r = 0.78 and 0.75, respectively). After controlling for covariates, patients with HF who had received an appropriate ICD intervention had higher expression levels of both WBC-derived SCN5A variants compared with patients with HF with ICDs who had not received appropriate ICD intervention (odds ratio, 3.25; 95% CI, 1.64-6.45; p = 0.001). Receiver operating characteristic analysis revealed that circulating SCN5A variant levels were highly associated with the risk for appropriate ICD intervention (area under the curve ≥0.97). Circulating expression levels of SCN5A variants were strongly associated with myocardial tissue levels. Furthermore, circulating variant levels were correlative with arrhythmic risk as measured by ICD events in an HF population within 1 year. (Sodium Channel Splicing in Heart Failure Trial [SOCS-HEFT]; NCT01185587). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  16. A second defibrillator chest patch electrode will increase implantation rates for nonthoracotomy defibrillators.

    Science.gov (United States)

    Solomon, A J; Swartz, J F; Rodak, D J; Moore, H J; Hannan, R L; Tracy, C M; Fletcher, R D

    1996-09-01

    Nonthoracotomy defibrillator systems can be implanted with a lower morbidity and mortality, compared to epicardial systems. However, implantation may be unsuccessful in up to 15% of patients, using a monophasic waveform. It was the purpose of this study to prospectively examine the efficacy of a second chest patch electrode in a nonthoracotomy defibrillator system. Fourteen patients (mean age 62 +/- 11 years, ejection fraction = 0.29 +/- 0.12) with elevated defibrillation thresholds, defined as > or = 24 J, were studied. The initial lead system consisted of a right ventricular electrode (cathode), a left innominate vein, and subscapular chest patch electrode (anodes). If the initial defibrillation threshold was > or = 24 J, a second chest patch electrode was added. This was placed subcutaneously in the anterior chest (8 cases), or submuscularly in the subscapular space (6 cases). This resulted in a decrease in the system impedance at the defibrillation threshold, from 72.3 +/- 13.3 omega to 52.2 +/- 8.6 omega. Additionally, the defibrillation threshold decreased from > or = 24 J, with a single patch, to 16.6 +/- 2.8 J with two patches. These changes were associated with successful implantation of a nonthoracotomy defibrillator system in all cases. In conclusion, the addition of a second chest patch electrode (using a subscapular approach) will result in lower defibrillation thresholds in patients with high defibrillation thresholds, and will subsequently increase implantation rates for nonthoracotomy defibrillators.

  17. Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads

    Directory of Open Access Journals (Sweden)

    Stylianos Paraskevaidis

    2014-01-01

    Full Text Available Background. Widespread use of cardiovascular implantable electronic devices has inevitably increased the need for lead revision/replacement. We report our experience in percutaneous extraction of transvenous permanent pacemaker/defibrillator leads. Methods. Thirty-six patients admitted to our centre from September 2005 through October 2012 for percutaneous lead extraction were included. Lead removal was attempted using Spectranetics traction-type system (Spectranetics Corp., Colorado, CO, USA and VascoExtor countertraction-type system (Vascomed GmbH, Weil am Rhein, Germany. Results. Lead extraction was attempted in 59 leads from 36 patients (27 men, mean ± SD age 61±5 years, with permanent pacemaker (n=25, defibrillator (n=8, or cardiac resynchronisation therapy (n=3 with a mean ± SD implant duration of 50±23 months. The indications for lead removal included pocket infection (n=23, endocarditis (n=2, and ventricular (n=10 and atrial lead dysfunction (n=1. Traction device was used for 33 leads and countertraction device for 26 leads. Mean ± SD fluoroscopy time was 4±2 minutes/lead for leads implanted 48 months (n=21, P=0.03. Complete procedural success rate was 91.7% and clinical procedural success rate was 100%, while lead procedural success rate was 95%. Conclusions. In conclusion, percutaneous extraction of transvenous permanent pacemaker/defibrillator leads using dedicated removal tools is both feasible and safe.

  18. Questionnaire in patients and doctors with ICD indication%植入型心律转复除颤器适应证患者及主管医生的问卷调查

    Institute of Scientific and Technical Information of China (English)

    宿燕岗; 吴妍; 柏瑾; 王蔚; 葛均波

    2010-01-01

    Objective Aim to understand the extraordinary low application of implantable cardioverter defibrillator(ICD) in China. Methods patients with ICD indication,their families and the attending doctors in Zhongshan Hospital of Fudan University were investigated by questionnaire from the period of June ,2007 to Janu-ary 2008. In addition, the basic information, examination results and treatment state were collected. Results There were 122 patients enrolled in this study,including 89 patients(73.0%)with the indication of primary pre-vention for SCD,which is 2.7 times compared with the patients of the secondary prevention. Non-ischemic heart diseases are the most common underlying cause in both primary and secondary SCD prevention. 42.4% of sec-ondary prevention patients accepted ICD/CRT-D implantation,while only 2.2% of primary prevention patients re-ceived device-based therapy. Age and education has no effect on the attitude of accepting ICD treatment. In the aspect of the recognition of suffered heart diseases, sudden cardiac death (SCD)and the acceptance of ICD,patients of secondary prevention are much better than the primary prevention ones(P<0.001). When come along with mak-ing the decision of whether accepted ICD implantation, the suggestion of physicians plays the most important role. The state of illness don't need ICD treatment other than economic issue is the main reason of the patients rejecting ICD implantation. The most physicians(93.3%)never introduced ICD to their primary prevention patients due to the same reason,which is much higher(21.1%)than the secondary prevention(P<0.001). Conclusions The clinical applications of ICD are far below its indication range at present,especial in the primary prevention. The lack of un-derstanding SCD and ICD in both physician and patient is the main reason for the low implantation of ICD in China.%目的 通过对植入型心律转复除颤器(ICD)适应证患者及主管医生的问卷调查探讨国内ICD

  19. Effect of cardiac resynchronization therapy-defibrillator implantation on health status in patients with mild versus moderate symptoms of heart failure

    DEFF Research Database (Denmark)

    Versteeg, Henneke; van den Broek, Krista C; Theuns, Dominic A M J;

    2011-01-01

    class III; n = 115) symptomatic CHF patients showed improved health status in several SF-36 domains at 12 months after CRT-D. When adjusting for baseline health status, the groups did not differ with respect to their health status improvement over time, but after adjustment for demographic and clinical...... status compared to NYHA functional class III patients at 12 months after CRT-D. Hence, CRT not only prevents clinical adverse events in patients with mild CHF symptoms but also improves health status.......Indications for cardiac resynchronization therapy (CRT) have expanded to include patients with mild congestive heart failure (CHF) symptoms (New York Heart Association [NYHA] functional class II) because of a demonstrated morbidity reduction in this subset of patients. However, little is known...

  20. The Role of Conventional and Right-Sided ECG Screening for Subcutaneous ICD in a Tetralogy of Fallot Population.

    Science.gov (United States)

    Alonso, Pau; Osca, Joaquín; Cano, Oscar; Pimenta, Pedro; Andrés, Ana; Yagüe, Jaime; Millet, José; Rueda, Joaquín; Sancho-Tello, María José

    2017-02-01

    Information regarding suitability for subcutaneous implantable cardioverter-defibrillator (S-ICD) implant in tetralogy of Fallot (ToF) population is scarce and needs to be further explored. (1) to determine the proportion of patients with ToF eligible for S-ICD, (2) to identify the optimal sensing vector in ToF patients, (3) to test specifically the eligibility for S-ICD with right-sided screening, and (4) to compare with the proportion of eligible patients in a nonselected ICD population. We recruited 60 consecutive patients with ToF and 40 consecutive nonselected patients. Conventional electrocardiographic screening was performed as usual. Right-sided alternative screening was studied by positioning the left arm and right arm electrodes 1 cm right lateral to the xiphoid midline. The Boston Scientific electrocardiogram (ECG) screening tool was utilized. We found a higher proportion of patients with right-sided positive screening in comparison with standard screening (77 ± 0.4% vs. 67 ± 0.4%; P right-sided screening (1.3 ± 1 vs. 1.1 ± 1 ms; P = 0.07). Patients who failed the screening had a longer QRS duration and longer QT interval. Standard and right-sided screening showed a higher percent of positive patients in the control group compared to ToF patients (P Right-sided screening was associated with a significant 10% increase in S-ICD eligibility in ToF patients. When comparing with an acquired cardiomyopathies group, ToF showed a lower eligibility for S-ICD. The most appropriate ECG vector was the alternate vector in contrast to what is observed in the general population. © 2017 Wiley Periodicals, Inc.

  1. Safety Profile of Liver FibroScan in Patients with Cardiac Pacemakers or Implantable Cardioverter-Defibrillators

    Science.gov (United States)

    Pranke, Stephanie; Rashidi, Farid; Nosib, Shravan; Worobetz, Lawrence

    2017-01-01

    Background. Emerging evidence suggests that nonalcoholic fatty liver disease (NAFLD) is associated with coronary artery diseases and arrhythmias. The FibroScan (Echosens, France), a widely available, noninvasive device, is able to detect liver fibrosis and steatosis within this patient population. However, the FibroScan is currently contraindicated in patients with cardiac pacemakers (PM) or implantable cardioverter-defibrillators (ICD). Objective. To determine the safety profile of FibroScan testing in patients with PM or ICD. Methods. Consecutive outpatients undergoing routine device interrogations at a tertiary level teaching hospital underwent simultaneous liver stiffness measurements. PM or ICD performance data, device types, patient demographics, medical history, and previous laboratory and conventional liver imaging results were collected. Results. Analysis of 107 subjects with 33 different types of implanted cardiac devices, from 5 different companies (Medtronic, Sorin, ELA Medical, Boston Scientific, and St. Jude), did not demonstrate any adverse events as defined by abnormal device sensing/pacing or ICD firing. This population included high risk subjects undergoing active pacing (n = 53) and with right pectoral PM placement (n = 1). None of the subjects had any clinical signs of decompensated congestive heart failure or cirrhosis during the exam. Conclusion. TE with FibroScan can be safely performed in patients with PM or ICD.

  2. Relationship between right and left ventricular function in candidates for implantable cardioverter defibrillator with low left ventricular ejection fraction.

    Science.gov (United States)

    Jimenez-Juan, Laura; Karur, Gauri R; Connelly, Kim A; Deva, Djeven; Yan, Raymond T; Wald, Rachel M; Singh, Sheldon; Leung, General; Oikonomou, Anastasia; Dorian, Paul; Angaran, Paul; Yan, Andrew T

    2017-04-01

    Indications for the primary prevention of sudden death using an implantable cardioverter defibrillator (ICD) are based predominantly on left ventricular ejection fraction (LVEF). However, right ventricular ejection fraction (RVEF) is also a known prognostic factor in a variety of structural heart diseases that predispose to sudden cardiac death. We sought to investigate the relationship between right and left ventricular parameters (function and volume) measured by cardiovascular magnetic resonance (CMR) among a broad spectrum of patients considered for an ICD. In this retrospective, single tertiary-care center study, consecutive patients considered for ICD implantation who were referred for LVEF assessment by CMR were included. Right and left ventricular function and volumes were measured. In total, 102 patients (age 62±14 years; 23% women) had a mean LVEF of 28±11% and RVEF of 44±12%. The left ventricular and right ventricular end diastolic volume index was 140±42 mL/m(2) and 81±27 mL/m(2), respectively. Eighty-six (84%) patients had a LVEF right ventricular systolic dysfunction. Although there was a significant and moderate correlation between LVEF and RVEF (r=0.40, pright ventricular systolic dysfunction (Kappa=0.041). Among patients being considered for an ICD, there is a positive but moderate correlation between LVEF and RVEF. A considerable proportion of patients who qualify for an ICD based on low LVEF have preserved RVEF, and vice versa.

  3. Electrical Heart Defibrillation with Ion Channel Blockers

    Science.gov (United States)

    Feeney, Erin; Clark, Courtney; Puwal, Steffan

    Heart disease is the leading cause of mortality in the United States. Rotary electrical waves within heart muscle underlie electrical disorders of the heart termed fibrillation; their propagation and breakup leads to a complex distribution of electrical activation of the tissue (and of the ensuing mechanical contraction that comes from electrical activation). Successful heart defibrillation has, thus far, been limited to delivering large electrical shocks to activate the entire heart and reset its electrical activity. In theory, defibrillation of a system this nonlinear should be possible with small electrical perturbations (stimulations). A successful algorithm for such a low-energy defibrillator continues to elude researchers. We propose to examine in silica whether low-energy electrical stimulations can be combined with antiarrhythmic, ion channel-blocking drugs to achieve a higher rate of defibrillation and whether the antiarrhythmic drugs should be delivered before or after electrical stimulation has commenced. Progress toward a more successful, low-energy defibrillator will greatly minimize the adverse effects noted in defibrillation and will assist in the development of pediatric defibrillators.

  4. From syncope to ICD: clinical paths of the Brugada syndrome

    Directory of Open Access Journals (Sweden)

    Ivan Comelli

    2010-09-01

    Full Text Available This review summarizes the evidences in the literature on the management of the Brugada syndrome (BS, an arrhythmogenic disease caused by genetic channelopathies, predisposing to syncope and sudden cardiac death in young, apparently healthy, typically male subjects, in the third and fourth decade of their life. Sudden cardiac death (SCD is defined as natural death from cardiac causes, heralded by abrupt loss of consciousness within one hour of the onset of symptoms. It ranks among the main causes of death in the western world, with an incidence ranging from 0.36 and 1.28‰ inhabitants per year, equal to 300,000 cases a year in the USA. In the majority of the cases it is due to the onset of arrhythmia in subjects with structural cardiac diseases, especially ischemic heart disease. However, in a non-negligible percentage of the cases, about 5-10%, the SCD arises in relatively young individuals in whom cardiac anomalies cannot be detected using traditional diagnostic techniques. About 20% of these cases can be attributed to SB. In spite of the many efforts produced to identify an effective pharmacological treatment, to date the only aid to reduce the mortality rate in subjects with SB is an implantable cardio-defibrillator (ICD. Since this approach often entails complications, the efforts of the scientific community is now focused on the assessment of the arrhythmic risk. The identification of high-risk subjects is one of the chief objectives in the therapeutic decision-making process. ABSTRACT clinica e terapia emergency

  5. Study of Cardiac Defibrillation Through Numerical Simulations

    Science.gov (United States)

    Bragard, J.; Marin, S.; Cherry, E. M.; Fenton, F. H.

    Three-dimensional numerical simulations of the defibrillation problem are presented. In particular, in this study we use the rabbit ventricular geometry as a realistic model system for evaluating the efficacy of defibrillatory shocks. Statistical data obtained from the simulations were analyzed in term of a dose-response curve. Good quantitative agreement between our numerical results and clinically relevant values is obtained. An electric field strength of about 6.6 V/cm indicates a fifty percent probability of successful defibrillation for a 12-ms monophasic shock. Our validated model will be useful for optimizing defibrillation protocols.

  6. Experiences of Young Adults With Pacemakers and/or Implantable Cardioverter Defibrillators.

    Science.gov (United States)

    Larimer, Karen; Durmus, Julie; Florez, Elizabeth

    The number of implanted devices (pacemakers [PMs] and implantable cardioverter defibrillators [ICDs]) is increasing. Because of technological advances, these devices are used in greater numbers in children and adolescents. Challenges of having these devices have been well studied in adults, but little is known about the lived experiences from the perspective of young adults. This study explored the lived experiences, coping behaviors, and challenges of young adults who had cardiac devices implanted during childhood. A descriptive qualitative study design was used. Purposive sampling was used to identify young adults aged 18 to 29 years, living with a PM and/or ICD. Participants were interviewed about their experiences and challenges related to living with a PM or ICD, with common themes identified and analyzed. A total of 6 participants were interviewed for this study. The challenges of living with a PM and/or ICD included insecurity about physical appearance, device compliance, physical sensations of the device, future uncertainty, and limited support. The identified coping behaviors utilized by the participants were confrontation, acceptance, educating others, spreading awareness, avoidance, and humor. The overall lived experiences described were appreciation for device benefits, fear of device malfunction, and attracting attention. The lived experiences of young recipients often mirror that of older adults; however, it is clear that there are challenges and coping behaviors unique to young adults living with a PM and/or ICD. It is important to educate healthcare providers about the unique challenges that young adults may face so they can provide the appropriate support to this population.

  7. Pulmonary fluid overload monitoring in heart failure patients with single and dual chamber defibrillators.

    Science.gov (United States)

    Molon, Giulio; Zanotto, Gabriele; Rahue, Werner; Facchin, Domenico; Leoni, Loira; Morani, Giovanni; Calvi, Valeria; Catanzariti, Domenico; Costa, Alessandro; Zago, Lara; Comisso, Jennifer; Varbaro, Annamaria; Santini, Massimo

    2014-04-01

    Heart failure has a relevant healthcare impact. Monitoring of pulmonary fluid overload (PFO), measured by intrathoracic impedance, has been proposed to alert to heart failure worsening before symptoms become patent. The aim of our research was to evaluate whether PFO diagnostics reduce heart failure hospitalizations in heart failure patients receiving single-chamber or dual-chamber implantable cardioverter-defibrillator (ICD) for primary prevention of sudden death. Twenty-five Italian cardiological centers prospectively followed 221 ICD patients (86% men, 66 ± 11 years, 79% New York Heart Association II and left ventricular ejection fraction 28 ± 5%), of whom 123 received an ICD with PFO monitoring (diagnostics group) and 98 an ICD without such a diagnostics (control group). The association of each patient to a group was assigned a priori, independently of patients' characteristics but based on regional device allocation policies. Patient clinical characteristics and observation period were similar between groups. In a mean follow-up of 17 ± 11 months, heart failure hospitalizations or emergency-room admissions occurred in eight (7%) patients of the diagnostics group and in 16 of the control group (16%; P = 0.02), with an incidence, measured by Kaplan-Meier analysis, of 23% at 2 years and 34% at 3 years in patients of the control group compared with 8% at 2 and 3 years in patients of the diagnostics group (Log rank test P = 0.044). Our data show that in heart failure patients receiving single-chamber or dual-chamber ICD, the use of intrathoracic impedance monitoring is associated with a significant reduction of heart failure hospitalizations. Our results support the hypothesis that PFO diagnostics improve the likelihood of timely detection of heart failure worsening.

  8. Consequences of the Diagnostic Criteria Proposed for the ICD-11 on the Prevalence of PTSD in Children and Adolescents.

    Science.gov (United States)

    Sachser, Cedric; Goldbeck, Lutz

    2016-04-01

    In 2013, a working group of the World Health Organization (WHO) proposed a reformulation of the posttraumatic stress disorder (PTSD) diagnostic criteria for the upcoming 11(th) edition of the International Classification of Diseases (ICD-11; Maercker, Brewin, Bryant, Cloitre, van Ommeren, et al., 2013). This study investigated the consequences of the proposed ICD-11 PTSD symptom reduction on the prevalence of PTSD in children and adolescents. Prevalence rates of PTSD in a clinical sample of 159 traumatized children and adolescents were compared applying criteria according to the 4(th) edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-IV; American Psychiatric Association, 1994), the ICD-10 (WHO, 1992), and the ICD-11. The prevalence rate was 76.1% using DSM-IV, 88.1% using ICD-10, and 61.0% using ICD-11. The use of the criteria proposed for ICD-11 resulted in 27.1% less positive cases compared with ICD-10 and 15.1% less positive cases compared with DSM-IV. Our results showed that in a clinical sample of children and adolescents the prevalence of PTSD was significantly affected by the use of different diagnostic systems. This will constitute a major challenge for research and practice because, depending on the algorithm used, different groups of patients will be included in studies and different groups of individuals will be able to access medical care and therapy.

  9. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005

    DEFF Research Database (Denmark)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt

    2017-01-01

    BACKGROUND AND PURPOSE: To examine the risk of cardiac conduction abnormalities or severe ventricular arrhythmias requiring implantation of a cardiac implantable electronic device (CIED), either a pacemaker or an implantable cardioverter-defibrillator, subsequent to breast cancer (BC) radiotherapy...... (RT). MATERIAL AND METHODS: All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence...

  10. MR Imaging in patients with cardiac pacemakers and implantable cardioverter defibrillators. Consensus paper of the German Cardiac Society and the German Roentgen Society; MR-Untersuchungen bei Patienten mit Herzschrittmachern und implantierbaren Kardioverter-Defibrillatoren. Konsensuspapier der Deutschen Gesellschaft fuer Kardiologie (DGK) und der Deutschen Roentgengesellschaft (DRG)

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Torsten [DRK Krankenhaus, Neuwied (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Bauer, Wolfgang [Deutsches Zentrum fuer Herzinsuffizienz Univ. Wuerzburg (Germany). Med. Klinik und Poliklinik I Univ. Klinikum Wuerzburg; Fischbach, Katharina [Universitaetsklinikum Magdeburg (Germany). Klinik fuer Radiologie und Nuklearmedizin; and others

    2017-03-15

    This joint consensus paper of the German Roentgen Society and the German Cardiac Society provides physical and electrophysiological background information and specific recommendations for the procedural management of patients with cardiac pacemakers (PM) and implantable cardioverter defibrillators (ICD) undergoing magnetic resonance (MR) imaging. The paper outlines the responsibilities of radiologists and cardiologists regarding patient education, indications, and monitoring with modification of MR sequences and PM/ICD reprogramming strategies being discussed in particular. The aim is to optimize patient safety and to improve legal clarity in order to facilitate the access of SM/ICD patients to MR imaging.

  11. Impact of the implantable cardioverter defibrillator on confidence to undertake physical activity in inherited heart disease: A cross-sectional study.

    Science.gov (United States)

    Sweeting, Joanna; Ball, Kylie; McGaughran, Julie; Atherton, John; Semsarian, Christopher; Ingles, Jodie

    2017-06-01

    Physical activity is associated with improved quality of life. Patients with an implantable cardioverter defibrillator (ICD) face unique clinical and psychological challenges. Factors such as fear of ICD shock may negatively impact on physical activity, while a sense of protection gained from the ICD may instil confidence to be active. We aimed to examine the impact of an ICD on physical activity levels and factors associated with amount of activity. Two cross-sectional studies were conducted. Accelerometer data (seven-day) was collected in March-November 2015 for 63 consecutively recruited hypertrophic cardiomyopathy patients, with or without an ICD, aged ⩾18 years. A survey study was conducted in July-August 2016 of 155 individuals aged ⩾18 years with an inherited heart disease and an ICD in situ. Based on the International Physical Activity Questionnaire, mean leisure time physical activity was 239 ± 300 min/week with 51% meeting physical activity guidelines. Accelerometry showed that mean moderate-vigorous physical activity was the same for patients with and without an ICD (254 ± 139 min/week versus 300 ± 150 min/week, p=0.23). Nearly half of survey participants ( n=73) said their device made them more confident to exercise. Being anxious about ICD shocks was the only factor associated with not meeting physical activity guidelines. Patients with inherited heart disease adjust differently to their ICD device, and for many it has no impact on physical activity. Discussion regarding the appropriate level of physical activity and potential barriers will ensure best possible outcomes in this unique patient group.

  12. Remote monitoring of implantable cardioverter-defibrillators. Problems and implications using a telemonitoring system.

    Science.gov (United States)

    Siebermair, J; Clauss, S; Martens, E; Schuessler, F; Oversohl, N; Haserueck, N; Estner, H L; Kääb, S; Wakili, R

    2015-04-01

    The rising number of implantable devices has led to an increase in device-related workload, e.g., regular interrogation follow-up visits. Telemonitoring systems for implantable cardioverter-defibrillators (ICDs) seem to be a promising tool for reducing workload and costs, and they have the potential of optimizing patient care. However, issues such as practical functionality of ICD telemonitoring in daily routine may affect its broad implementation. The objective of this study was to evaluate potential problems during the implementation of a telemonitoring system, Medtronic CareLink™ (CL™) with respect to the installation and data transmission process. A total of 159 patients with ICDs who were equipped with the CL™ system were evaluated and followed up for 16 months regarding the success rate of the first data transmission via the telemonitoring system. In this cohort, a high rate of nontransmission of 23.9 % was observed after the 16-month follow-up. A detailed interview of these patients (no transmission) revealed that the main reasons for failed transmissions were due to the patients' loss of interest in the concept (approximately 50 %) as well as technical problems (approximately 25 %) with setting up the system. These results indicate that telemonitoring systems bear potential problems and that the evaluation of patient motivation and technical support options seems to play an important role in establishing the functionality of these systems.

  13. [Guidelines on the management of implantable cardioverter defibrillators at the end of life].

    Science.gov (United States)

    Datino, T; Rexach, L; Vidán, M T; Alonso, A; Gándara, Á; Ruiz-García, J; Fontecha, B; Martínez-Sellés, M

    2014-01-01

    This article is a joint document of the Spanish Society of Geriatrics and Gerontology, the Spanish Society of Palliative Care and the Section of Geriatric Cardiology of the Spanish Society of Cardiology. Its aim is to address the huge gap that exists in Spain with regard to the management of implantable cardioverter defibrillators (ICDs) in the final stages of life. It is increasingly common to find patients carrying these devices that are in the terminal stage of an advanced disease. This occurs in patients with advanced heart disease and subsequent heart failure refractory to treatment but also in a patient with an ICD who develops cancer disease, organ failure or other neurodegenerative diseases with poor short-term prognosis. The vast majority of these patients are over 65, so the paper focuses particularly on the elderly who are in this situation, but the decision-making process is similar in younger patients with ICDs who are in the final phase of their life. Copyright © 2013 SEGG. Published by Elsevier Espana. All rights reserved.

  14. Guidelines on the management of implantable cardioverter defibrillators at the end of life.

    Science.gov (United States)

    Datino, T; Rexach, L; Vidán, M T; Alonso, A; Gándara, Á; Ruiz-García, J; Fontecha, B; Martínez-Sellés, M

    2014-01-01

    This article is a joint document of the Spanish Society of Geriatrics and Gerontology, the Spanish Society of Palliative Care and the Section of Geriatric Cardiology of the Spanish Society of Cardiology. Its aim is to address the huge gap that exists in Spain with regard to the management of implantable cardioverter defibrillators (ICDs) in the final stages of life. It is increasingly common to find patients carrying these devices that are in the terminal stage of an advanced disease. This occurs in patients with advanced heart disease and subsequent heart failure refractory to treatment but also in a patient with an ICD who develops cancer disease, organ failure or other neurodegenerative diseases with poor short-term prognosis. The vast majority of these patients are over 65, so the paper focuses particularly on the elderly who are in this situation, but the decision-making process is similar in younger patients with ICDs who are in the final phase of their life. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  15. Long-term mortality risk in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Theuns, Dominic A M J; Pedersen, Susanne S.

    2014-01-01

    risk in first-time ICD patients, adjusting also for measures of emotional distress. METHODS: Resting heart rate and QRS duration were assessed prior to ICD implantation in 448 patients. Primary study endpoint was all-cause mortality (up to 6.0 year follow-up, median follow-up of 5.6 years (IQR: 1......BACKGROUND: A paucity of studies has investigated the role of autonomic cardiac regulation as well as cardiac conduction in relation to prognosis in implantable cardioverter-defibrillator (ICD) patients. Therefore, we examined the association of heart rate and QRS duration with long-term mortality.......9)). The impact of heart rate and QRS duration on time to all-cause mortality was separately assessed with Cox proportional hazard regression analysis, adjusting for clinical factors and symptoms of depression and anxiety. RESULTS: Mean (SD) heart rate was 68.0 ± 13.3 bpm and mean QRS duration was 130.9 ± 36.9 ms...

  16. Reliability of clinical ICD-10 schizophrenia diagnoses

    DEFF Research Database (Denmark)

    Jakobsen, Klaus D; Frederiksen, Julie N; Hansen, Thomas;

    2005-01-01

    value (87%) of ICD-10 schizophrenia and an overall good agreement between clinical and OPCRIT-derived diagnoses (kappa=0.60). An even higher positive predictive value was obtained when diagnoses were amalgamated into a diagnostic entity of schizophrenia-spectrum disorders (98%). Near perfect agreement...

  17. Relation of symptomatic heart failure and psychological status to persistent depression in patients with implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Pedersen, Susanne S.; Hoogwegt, Madelein T; Jordaens, Luc

    2011-01-01

    Association class III-IV (OR 2.95; 95% CI 1.47 to 5.89), Type D personality (OR 7.98; 95% CI 3.98 to 16.04), and the use of psychotropic medication (OR 2.73; 95% CI 1.27 to 5.84) were independent correlates of persistent depression. In conclusion, symptomatic heart failure, psychological status......Studies on psychological morbidity in patients with an implantable cardioverter-defibrillator (ICD) have focused on mean differences rather than intraindividual differences. Such an approach masks the chronicity of symptoms in individual patients and the potential differences in cardiac outcomes....... We examined the prevalence and correlates of persistent depression using an intraindividual approach. Consecutive patients who had undergone ICD implantation (n = 386; 79.3% men) completed a set of validated questionnaires, including the Hospital Anxiety and Depression Scale (HADS), at baseline and 3...

  18. COPE-ICD: Patient experience of participation in an ICD specific rehabilitation programme

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Pedersen, Birthe Dagmar; Svendsen, Jesper Hastrup

    2012-01-01

    PURPOSE: Evaluating rehabilitation programmes from the patient's perspective is much needed, as the patients are the most important stakeholders in the health care system. A comprehensive rehabilitation programme, COPE-ICD programme, consists of exercise training and nursing consultations during...... a one year period post ICD implantation. The purpose of this paper is to describe the experience and meaning of participating in a comprehensive ICD-specific rehabilitation programme. METHODS: Qualitative interviews were conducted with 10 patients representing the participating population, and later...... transcribed. The analysis was inspired by Ricoeur's theory of interpretation, which consists of three levels: naive reading, structured analysis and critical interpretation and discussion. RESULTS: The overall concept was that participating in the COPE-ICD programme meant feeling inspired and secure through...

  19. Desfibrilador automático implantado en pacientes con miocardiopatía hipertrófica: criterios de selección, evolución y predictores de terapia apropiada Automatic defibrillator implanted in patients with hypertrophic myocardiopathy: selection criteria, evolution and appropriate therapy predictors

    Directory of Open Access Journals (Sweden)

    Guillermo Mora

    Full Text Available Introducción y objetivos: la miocardiopatía hipertrófica es una enfermedad de origen genético con prevalencia de 1% al 2%. La mitad de los pacientes fallecen por muerte súbita cardiaca, la mayoría por arritmias ventriculares. Todavía no está claro a qué pacientes se les debe implantar un desfibrilador automático. El objetivo de este trabajo es describir una serie de pacientes con implante, los criterios empleados y los resultados obtenidos, así como analizar los predictores de terapia apropiada por el desfibrilador. Métodos: se incluyeron 20 pacientes que recibieron un desfibrilador de tercera generación. En todos se realizó estudio electrofisiológico y seguimiento prospectivo con registro de eventos. En 18 (90% se hizo estudio genético. Resultados: el 55% eran hombres con edad promedio de 40 [11-78] años. Seis (30% recibieron implantante por prevención secundaria y 14 (70% por prevención primaria; los últimos por presentar varios factores de riesgo. Se indujo una arritmia sostenida en 15 (75% y en 3 (15% taquicardia ventricular monomórfica sostenida. A 22 meses de seguimiento 4 (20% sufrieron terapia apropiada y 2 (10% fallecieron. La taquicardia ventricular monomórfica clínica (p=0,03 y la inducida (pIntroduction and objectives: hypertrophic myocardiopathy is a genetic entity with 1% to 2% prevalence. Half patients die of sudden cardiac death, most due to ventricular arrhythmias. There is still no clarity with regard to the patients to whom an automatic defibrillator has to be implanted. The objective of this work is to describe a series of patients with implant, the criteria used and the results obtained, as well as to analyze the predictors of appropriate therapy with the defibrillator. Methods: 20 patients that received a third generation defibrillator were included. Electrophysiological study and prospective follow-up with register of events was performed in all. Genetic study was done in 18 (90%. Results: 55% were

  20. Entirely subcutaneous defibrillator and complex congenital heart disease: Data on long-term clinical follow-up

    Science.gov (United States)

    Ferrero, Paolo; Ali, Hussam; Barman, Palash; Foresti, Sara; Lupo, Pierpaolo; D’Elia, Emilia; Cappato, Riccardo; Stuart, Alan Graham

    2017-01-01

    AIM To describe the long-term follow-up of patients with complex congenital heart disease who underwent subcutaneous implantable cardiac defibrillator (S-ICD), focusing on local complications, appropriate and inappropriate shocks. METHODS Patients with complex congenital heart disease underwent S-ICD implant in two centers with the conventional technique. Data at follow-up were retrieved from clinical notes and institutional database. RESULTS Eight patients were implanted in two centres between 2010 and 2016. Median age at implant was 37.5 years (range 13-57). All patients who were deemed suitable for S-ICD implant passed the pre-procedural screening. Three patients were previously implanted with a anti-bradycardia device, one of whom with CRT. In one patient the device was explanted due to local infection. During the total median follow-up of 874 d, one patient had an appropriate and one inappropriate shock triggered by fast atrial tachycardia. None of the patients had inappropriate shocks secondary to T wave oversensing or electrical interference with anti- bradycardia devices. CONCLUSION S-ICD appears to be effective and safe in patients with complex congenital heart disease. PMID:28706590

  1. Arrhythmia Diagnosis Following an ICD Shock: Part II

    Directory of Open Access Journals (Sweden)

    Roy M. John

    2002-07-01

    Full Text Available In ICD systems that incorporate biventricular pacing, lack of univentricular sensing capability, as in this case, will lead to double counting and ICD shocks for slow ventricular arrhythmias. The newer generation cardiac resynchronization ICDs will overcome this issue by limiting sensing to the right ventricular channel.

  2. Comparison of ICD-10 and Gillberg's Criteria for Asperger Syndrome.

    Science.gov (United States)

    Leekam, Susan; Libby, Sarah; Wing, Lorna; Gould, Judith; Gillberg, Christopher

    2000-01-01

    This study compared the ICD-10 criteria for Asperger syndrome with those suggested by Gillberg with 200 children and adults who met ICD-10 criteria for autism. Comparison indicated only three subjects met ICD-10 criteria for Asperger syndrome whereas 91 met Gillberg's criteria. The discrepancy appeared due to the specific "normal development"…

  3. Potential clinical impact of cardiovascular magnetic resonance assessment of ejection fraction on eligibility for cardioverter defibrillator implantation

    Directory of Open Access Journals (Sweden)

    Joshi Subodh B

    2012-10-01

    Full Text Available Abstract Background For the primary prevention of sudden cardiac death, guidelines provide left ventricular ejection fraction (EF criteria for implantable cardioverter defibrillator (ICD placement without specifying the technique by which it should be measured. We sought to investigate the potential impact of performing cardiovascular magnetic resonance (CMR for EF on ICD eligibility. Methods The study population consisted of patients being considered for ICD implantation who were referred for EF assessment by CMR. Patients who underwent CMR within 30 days of echocardiography were included. Echocardiographic EF was determined by Simpson’s biplane method and CMR EF was measured by Simpson’s summation of discs method. Results Fifty-two patients (age 62±15 years, 81% male had a mean EF of 38 ± 14% by echocardiography and 35 ± 14% by CMR. CMR had greater reproducibility than echocardiography for both intra-observer (ICC, 0.98 vs 0.94 and inter-observer comparisons (ICC 0.99 vs 0.93. The limits of agreement comparing CMR and echocardiographic EF were – 16 to +10 percentage points. CMR resulted in 11 of 52 (21% and 5 of 52 (10% of patients being reclassified regarding ICD eligibility at the EF thresholds of 35 and 30% respectively. Among patients with an echocardiographic EF of between 25 and 40%, 9 of 22 (41% were reclassified by CMR at either the 35 or 30% threshold. Echocardiography identified only 1 of the 6 patients with left ventricular thrombus noted incidentally on CMR. Conclusions CMR resulted in 21% of patients being reclassified regarding ICD eligibility when strict EF criteria were used. In addition, CMR detected unexpected left ventricular thrombus in almost 10% of patients. Our findings suggest that the use of CMR for EF assessment may have a substantial impact on management in patients being considered for ICD implantation.

  4. Costs of remote monitoring vs. ambulatory follow-ups of implanted cardioverter defibrillators in the randomized ECOST study

    Science.gov (United States)

    Guédon-Moreau, Laurence; Lacroix, Dominique; Sadoul, Nicolas; Clémenty, Jacques; Kouakam, Claude; Hermida, Jean-Sylvain; Aliot, Etienne; Kacet, Salem

    2014-01-01

    Aims The Effectiveness and Cost of ICD follow-up Schedule with Telecardiology (ECOST) trial evaluated prospectively the economic impact of long-term remote monitoring (RM) of implantable cardioverter defibrillators (ICDs). Methods and results The analysis included 310 patients randomly assigned to RM (active group) vs. ambulatory follow-ups (control group). Patients in the active group were seen once a year unless the system reported an event mandating an ambulatory visit, while patients in the control group were seen in the ambulatory department every 6 months. The costs of each follow-up strategy were compared, using the actual billing documents issued by the French health insurance system, including costs of (i) (a) ICD-related ambulatory visits and transportation, (b) other ambulatory visits, (c) cardiovascular treatments and procedures, and (ii) hospitalizations for the management of cardiovascular events. The ICD and RM system costs were calculated on the basis of the device remaining longevity at the end of the study. The characteristics of the study groups were similar. Over a follow-up of 27 months, the mean non-hospital costs per patient-year were €1695 ± 1131 in the active, vs. €1952 ± 1023 in the control group (P = 0.04), a €257 difference mainly due to device management. The hospitalization costs per patient-year were €2829 ± 6382 and €3549 ± 9714 in the active and control groups, respectively (P = 0.46). Adding the ICD to the non-hospital costs, the savings were €494 (P = 0.005) or, when the monitoring system was included, €315 (P = 0.05) per patient-year. Conclusion From the French health insurance perspective, the remote management of ICD patients is cost saving. Clinical trials registration NCT00989417, www.clinicaltrials.gov PMID:24614572

  5. PTSD in ICD-10 and proposed ICD-11 in elderly with childhood trauma: prevalence, factor structure, and symptom profiles

    OpenAIRE

    Glück, Tobias M.; Knefel, Matthias; Tran, Ulrich S.; Lueger-Schuster, Brigitte

    2016-01-01

    Background: The proposal for ICD-11 postulates major changes for posttraumatic stress disorder (PTSD) diagnosis, which needs investigation in different samples.Aims: To investigate differences of PTSD prevalence and diagnostic agreement between ICD-10 and ICD-11, factor structure of proposed ICD-11 PTSD, and diagnostic value of PTSD symptom severity classes.Method: Confirmatory factor analysis and latent profile analysis were used on data of elderly survivors of childhood trauma (>60 years...

  6. The ERα coactivator, HER4/4ICD, regulates progesterone receptor expression in normal and malignant breast epithelium

    Directory of Open Access Journals (Sweden)

    Howard Beatrice A

    2010-06-01

    Full Text Available Abstract The HER4 intracellular domain (4ICD is a potent estrogen receptor (ERα coactivator with activities in breast cancer and the developing mammary gland that appear to overlap with progesterone receptor (PgR. In fact, 4ICD has recently emerged as an important regulator and predictor of tamoxifen response, a role previously thought to be fulfilled by PgR. Here we investigated the possibility that the 4ICD coactivator regulates PgR expression thereby providing a mechanistic explanation for their partially overlapping activities in breast cancer. We show that 4ICD is both sufficient and necessary to potentiate estrogen stimulation of gene expression. Suppression of HER4/4ICD expression in the MCF-7 breast tumor cell line completely eliminated estrogen stimulated expression of PgR. In addition, the HER4/4ICD negative MCF-7 variant, TamR, failed to express PgR in response to estrogen. Reintroduction of wild-type HER4 but not the γ-secretase processing mutant HER4V673I into the TamR cell line restored PgR expression indicating that 4ICD is an essential PgR coactivator in breast tumor cells. These results were substantiated in vivo using two different physiologically relevant experimental systems. In the mouse mammary gland estrogen regulates expression of PgR-A whereas expression of PgR-B is estrogen independent. Consistent with a role for 4ICD in estrogen regulated PgR expression in vivo, PgR-A, but not PgR-B, expression was abolished in HER4-null mouse mammary glands during pregnancy. Coexpression of PgR and 4ICD is also commonly observed in ERα positive breast carcinomas. Using quantitative AQUA IHC technology we found that 4ICD potentiated PgR expression in primary breast tumors and the highest levels of PgR expression required coexpression of ERα and the 4ICD coactivator. In summary, our results provide compelling evidence that 4ICD is a physiologically important ERα coactivator and 4ICD cooperates with ERα to potentiate PgR expression

  7. Stereotyped movement disorder in ICD-11.

    Science.gov (United States)

    Stein, Dan J; Woods, Douglas W

    2014-01-01

    According to current proposals for ICD-11, stereotyped movement disorder will be classified in the grouping of neurodevelopmental disorders, with a qualifier to indicate whether self-injury is present, similar to the classification of stereotypic movement disorder in DSM-5. At the same time, the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders has proposed a grouping of body-focused repetitive behavior disorders within the obsessive-compulsive and related disorders (OCRD) cluster to include trichotillomania and skin-picking disorder. DSM-5 has taken a slightly different approach: trichotillomania and excoriation (skin picking) disorder are included in the OCRD grouping, while body-focused repetitive behavior disorder is listed under other specified forms of OCRD. DSM-5 also includes a separate category of nonsuicidal self-injury in the section on "conditions for further study." There are a number of unresolved nosological questions regarding the relationships among stereotyped movement disorder, body-focused repetitive behavior disorders, and nonsuicidal self-injury. In this article, we attempt to provide preliminary answers to some of these questions as they relate to the ICD-11 classification of mental and behavioral disorders.

  8. [Research on automatic external defibrillator based on DSP].

    Science.gov (United States)

    Jing, Jun; Ding, Jingyan; Zhang, Wei; Hong, Wenxue

    2012-10-01

    Electrical defibrillation is the most effective way to treat the ventricular tachycardia (VT) and ventricular fibrillation (VF). An automatic external defibrillator based on DSP is introduced in this paper. The whole design consists of the signal collection module, the microprocessor controlingl module, the display module, the defibrillation module and the automatic recognition algorithm for VF and non VF, etc. This automatic external defibrillator has achieved goals such as ECG signal real-time acquisition, ECG wave synchronous display, data delivering to U disk and automatic defibrillate when shockable rhythm appears, etc.

  9. Posttraumatic stress and anxiety in patients with an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Habibović, Mirela; Denollet, J; Pedersen, S S

    2017-01-01

    the trajectories of symptoms of posttraumatic stress disorder (PTSD) and anxiety in patients with an ICD and the vulnerability factors associated with an increased risk of symptoms of PTSD and anxiety. METHODS: A total of 249 patients were included as part of the WEB-based distress program for implantable...... CARdioverter dEfibrillator patients (WEBCARE) study. Data were analyzed using Latent class analyses, with trajectories of PTSD symptomatology and anxiety examined between baseline and 12 months follow-up. RESULTS: The mean age of the sample was 58.9±9.8, with the majority being male (82%). Latent Class...... analyses (LatentGOLD) revealed four classes with respect to PTSD symptomatology, and three classes of patients with respect to anxiety. Younger age, increased depression score at baseline, and Type D personality were all associated with increased vulnerability for posttraumatic stress and anxiety symptoms...

  10. Imaging of Ventricular Fibrillation and Defibrillation: The Virtual Electrode Hypothesis.

    Science.gov (United States)

    Boukens, Bastiaan J; Gutbrod, Sarah R; Efimov, Igor R

    2015-01-01

    Ventricular fibrillation is the major underlying cause of sudden cardiac death. Understanding the complex activation patterns that give rise to ventricular fibrillation requires high resolution mapping of localized activation. The use of multi-electrode mapping unraveled re-entrant activation patterns that underlie ventricular fibrillation. However, optical mapping contributed critically to understanding the mechanism of defibrillation, where multi-electrode recordings could not measure activation patterns during and immediately after a shock. In addition, optical mapping visualizes the virtual electrodes that are generated during stimulation and defibrillation pulses, which contributed to the formulation of the virtual electrode hypothesis. The generation of virtual electrode induced phase singularities during defibrillation is arrhythmogenic and may lead to the induction of fibrillation subsequent to defibrillation. Defibrillating with low energy may circumvent this problem. Therefore, the current challenge is to use the knowledge provided by optical mapping to develop a low energy approach of defibrillation, which may lead to more successful defibrillation.

  11. [Chronic transvenous pacemaker/implantable cardioverter defibrillator leads implantation induced pathological changes].

    Science.gov (United States)

    Li, Yanhui; Dykoski, Richard; Li, Jianming

    2015-05-01

    Widely pacemaker/implantable cardioverter defibrillator (ICD) implantation is also related to an increasing need for transvenous lead extraction. Understanding the location and extent of pathological changes, including adhesions and fibrous tissue formation along the course of chronic pacemaker/ICD leads, are essential for operators performing lead extraction operations in order to reduce the potential life threatening complications. Three parts are included in the research, pathological examination on 83 extracted pacemaker/ICD leads using excimer laser technique from March 2008 to March 2011, autopsy examination of one died patient during lead extraction for lead-related infective endocarditis, and anatomical analysis on pacemaker/ICD leads from 10 patients died of other non-cardiac causes. Extensive encapsulated fibrous tissue around the leads and extensive adhesion/fibrosis along the course of the leads from venous entry site to the lead/myocardial interface could be detected on transvenous pacemaker/ICD leads. Since the tissue at the junction between superior vena cava (SVC) and right atrium (RA) is very thin, free of pericardium, thus, this is a common place for extensive adhesion/fibrosis and myocardial perforation/tear during lead extraction, which accounted for one death during extraction in our cohort. Extensive adhesion and fibrosis were also observed at the tricuspid valve and subvalvular structures. Leads implanted to the right ventricular apex were close to the epicardial surface and prone to perforation through myocardium. It is common to observe thrombus on the leads or at the interface between leads and myocardial tissue, especially at right atrial appendage (RAA) at the site of lead insertion. Extensive adhesions and fibrosis can be commonly seen along the course of pacemaker/ICD leads, and at SVC to RA junction, the tricuspid valve/subvalvular structures, and RA/RV lead interface. The tissue at SVC to RA junction is very thin, making it

  12. Complications after cardiac implantable electronic device implantations

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard;

    2014-01-01

    Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...

  13. A study to improve communication between clinicians and patients with advanced heart failure: methods and challenges behind the working to improve discussions about defibrillator management trial.

    Science.gov (United States)

    Goldstein, Nathan E; Kalman, Jill; Kutner, Jean S; Fromme, Erik K; Hutchinson, Mathew D; Lipman, Hannah I; Matlock, Daniel D; Swetz, Keith M; Lampert, Rachel; Herasme, Omarys; Morrison, R Sean

    2014-12-01

    We report the challenges of the Working to Improve Discussions About Defibrillator Management trial, our novel, multicenter trial aimed at improving communication between cardiology clinicians and their patients with advanced heart failure (HF) who have implantable cardioverter defibrillators (ICDs). The study objectives are (1) to increase ICD deactivation conversations, (2) to increase the number of ICDs deactivated, and (3) to improve psychological outcomes in bereaved caregivers. The unit of randomization is the hospital, the intervention is aimed at HF clinicians, and the patient and caregiver are the units of analysis. Three hospitals were randomized to usual care and three to intervention. The intervention consists of an interactive educational session, clinician reminders, and individualized feedback. We enroll patients with advanced HF and their caregivers, and then we regularly survey them to evaluate whether the intervention has improved communication between them and their HF providers. We encountered three implementation barriers. First, there were institutional review board concerns at two sites because of the palliative nature of the study. Second, we had difficulty in creating entry criteria that accurately identified an HF population at high risk of dying. Third, we had to adapt our entry criteria to the changing landscape of ventricular assist devices and cardiac transplant eligibility. Here we present our novel solutions to the difficulties we encountered. Our work has the ability to enhance conduct of future studies focusing on improving care for patients with advanced illness.

  14. Effect of psycho-educational interventions on quality of life in patients with implantable cardioverter defibrillators: a meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Kao, Chi-Wen; Chen, Miao-Yi; Chen, Ting-Yu; Lin, Pai-Hui

    2016-09-30

    Implantable cardioverter defibrillators (ICD) were developed for primary and secondary prevention of sudden cardiac death. However, ICD recipients' mortality is significantly predicted by their quality of life (QOL). The aim of this meta-analysis was to evaluate the effects of psycho-educational interventions on QOL in patients with ICDs. We systematically searched PubMed, Medline, Cochrane Library, and CINAHL through April 2015 and references of relevant articles. Studies were reviewed if they met following criteria: (1) randomized controlled trial, (2) participants were adults with an ICD, and (3) data were sufficient to evaluate the effect of psychological or educational interventions on QOL measured by the SF-36 or SF-12. Studies were independently selected and their data were extracted by two reviewers. Study quality was evaluated using a modified Jadad scale. The meta-analysis was conducted using the Cochrane Collaboration's Review Manager Software Package (RevMan 5). Study heterogeneity was assessed by Q statistics and I (2) statistic. Depending on heterogeneity, data were pooled across trials using fixed-effect or random-effect modeling. Seven randomized controlled trials fulfilled the inclusion and exclusion criteria, and included 1017 participants. The psycho-educational interventions improved physical component summary (PCS) scores in the intervention groups more than in control groups (mean difference 2.08, 95 % CI 0.86 to 3.29, p educational interventions improved the physical component, but not the mental component of QOL in patients with ICDs.

  15. Technologic advances and program initiatives in public access defibrillation using automated external defibrillators.

    Science.gov (United States)

    White, R D

    2001-06-01

    Widespread provision of early defibrillation following cardiac arrest holds major promise for improved survival from ventricular fibrillation. The critical element in predicting a successful outcome is the rapidity with which defibrillation is achieved. A worldwide awareness of this potential and its advocacy by such organizations as the American Heart Association have been pivotal in the evolution of initiatives to make defibrillation more widely and more rapidly available. The feasibility of this initiative, known as public access defibrillation, is in large measure a direct consequence of major technologic advances in automated external defibrillators (AEDs). New low-energy waveforms with biphasic morphology have been shown to be more effective in terminating ventricular fibrillation and may do so with less myocardial injury. Placement of AEDs in a variety of nontraditional settings such as police cars, aircraft and airport terminals, and gambling casinos has been shown to yield an impressive number of survivors of cardiac arrest in ventricular fibrillation. Questions yet to be answered center on the appropriate disposition of AEDs in public access defibrillation settings, training and retraining issues, device maintenance, and collection of accurate data to document benefit and to identify areas of needed improvement or expansion of AED availability.

  16. Changes in Follow-up Left Ventricular Ejection Fraction Associated with Outcomes in Primary Prevention ICD and CRT-D Recipients

    Science.gov (United States)

    Zhang, Yiyi; Guallar, Eliseo; Blasco-Colmenares, Elena; Butcher, Barbara; Norgard, Sanaz; Nauffal, Victor; Marine, Joseph E.; Eldadah, Zayd; Dickfeld, Timm; Ellenbogen, Kenneth A.; Tomaselli, Gordon F.; Cheng, Alan

    2015-01-01

    BACKGROUND Heart failure patients with primary prevention implantable cardioverter-defibrillators (ICD) may experience an improvement in left ventricular ejection fraction (LVEF) over time. However, it is unclear how LVEF improvement affects subsequent risk for mortality and sudden cardiac death (SCD). OBJECTIVES We sought to assess changes in LVEF after ICD implantation and the implication of these changes on subsequent mortality and ICD shocks. METHODS We conducted a prospective cohort study of 538 patients with repeated LVEF assessments after ICD implantation for primary prevention of SCD. The primary endpoint was appropriate ICD shock, defined as a shock for ventricular tachyarrhythmias. The secondary endpoint was all-cause mortality. RESULTS Over a mean follow-up of 4.9 years, LVEF decreased in 13.0%, improved in 40.0%, and was unchanged in 47.0% of the patients. In the multivariate Cox models comparing patients with an improved LVEF to those with an unchanged LVEF, the hazard ratios were 0.33 (95% confidence interval [CI]: 0.18 to 0.59) for mortality and 0.29 (95% CI: 0.11 to 0.78) for appropriate shock, respectively. During follow-up, 25% of patients showed an improvement in LVEF to >35% and their risk of appropriate shock decreased but was not eliminated. CONCLUSION Among primary prevention ICD patients, 40.0% had an improved LVEF during follow-up and 25% had LVEF improved to >35%. Changes in LVEF were inversely associated with all-cause mortality and appropriate shock for ventricular tachyarrhythmia. In patients whose follow-up LVEF improved to >35%, the risk of an appropriate shock remained but was markedly decreased. PMID:26227190

  17. 75 FR 70015 - External Defibrillators; Public Workshop

    Science.gov (United States)

    2010-11-16

    ... of innovative AED features such as automated integration into local 9-1-1 systems. FDA will work with... consumers, to share perspectives. II. Topics for Discussion at the Public Workshop The public workshop will... signals, or enhance the use of external defibrillators? III. Transcripts Please be advised that as soon...

  18. [Cardiac Pacemakers, implantable defibrillators and IRM].

    Science.gov (United States)

    Frank, R; Hidden-Lucet, F; Himbert, C; Petitot, J C; Fontaine, G

    2003-04-01

    The IRM is formally contraindicated to the pacemaker and cardiac defibrillator wearers because of the risk of inhibition or inappropriate stimulations during the examination. However if the examination is essential, suitable programming of the apparatus and a constant monitoring of the heartbeat rate by a qualified doctor in cardiac stimulation must make it possible to avoid any accident.

  19. Ventricular Tachyarrhythmias and Mortality in Patients With an Implantable Cardioverter Defibrillator

    DEFF Research Database (Denmark)

    Mastenbroek, Mirjam H; Versteeg, Henneke; Jordaens, Luc

    2014-01-01

    .1] years) completed the Hospital Anxiety and Depression Scale 1 day before implantation. During follow-up, the ICD was interrogated at 3-month intervals. Cox proportional hazard regression analyses were used to examine the impact of depression on time to first appropriate ICD therapy and all-cause...... with an increased risk for all-cause mortality (unadjusted HR = 2.18, 95% CI = 1.36-3.49). Depression remained independently associated with all-cause mortality (HR = 1.94, 95% CI = 1.06-3.54, p = .031), after adjusting for demographic and clinical characteristics. Patients who remained depressed during the first 3...... months after implantation were at greatest risk for dying (HR = 2.88, 95% CI = 1.29-6.45, p = .010). Conclusions The current study showed that depression at the time of implant is not associated with time to first appropriate ICD therapy but almost doubled the risk for all-cause mortality in patients...

  20. Cardioverter-defibrillator implantation to treat cardiac fibroma-induced ventricular tachycardia in a 70-year-old woman.

    Science.gov (United States)

    Hakim, Fayaz Ahmad; Pandit, Anil; Mookadam, Farouk; Mamby, Sylvia

    2014-06-01

    Benign cardiac fibroma is rarely reported in adults. Its clinical symptoms are related to outflow obstruction or dysrhythmias. We present the case of a 70-year-old woman who had a syncopal episode from ventricular tachycardia caused by cardiac fibroma. Because of unfavorable tumor anatomy, the patient was not a candidate for surgical excision, and she declined orthotopic heart transplantation. To prevent sudden cardiac death, we placed an implantable cardioverter-defibrillator, and the patient remained well throughout the 2-year follow-up period. To our knowledge, this is the first report of implantable cardioverter-defibrillator therapy to treat an adult patient's unresectable cardiac fibroma.

  1. PTSD in ICD-10 and proposed ICD-11 in elderly with childhood trauma: prevalence, factor structure, and symptom profiles

    Directory of Open Access Journals (Sweden)

    Tobias M. Glück

    2016-01-01

    Full Text Available Background: The proposal for ICD-11 postulates major changes for posttraumatic stress disorder (PTSD diagnosis, which needs investigation in different samples. Aims: To investigate differences of PTSD prevalence and diagnostic agreement between ICD-10 and ICD-11, factor structure of proposed ICD-11 PTSD, and diagnostic value of PTSD symptom severity classes. Method: Confirmatory factor analysis and latent profile analysis were used on data of elderly survivors of childhood trauma (>60 years, N=399. Results: PTSD rates differed significantly between ICD-10 (15.0% and ICD-11 (10.3%, z=2.02, p=0.04. Unlike previous research, a one-factor solution of ICD-11 PTSD had the best fit in this sample. High symptom profiles were associated with PTSD in ICD-11. Conclusions: ICD-11 concentrates on PTSD's core symptoms and furthers clinical utility. Questions remain regarding the tendency of ICD-11 to diagnose mainly cases with severe symptoms and the influence of trauma type and participant age on the factor structure.

  2. [Positive microvolt T-wave alternans as a marker of ventricular arrhythmia trigering during cardioverter-defibrillator implantation].

    Science.gov (United States)

    Wierzbowski, Robert; Michałkiewicz, Dariusz; Cholewa, Marian; Jacewicz, Katarzyna; Gniłka, Anna; Adamus, Jerzy

    2006-10-01

    Microvolt T-wave alternans (MTWA) is promising method for noninvasive assessment of arrhythmic risk, but its role hasn't established yet. The aim of this study was to establish the MTWA potency to predict the ventricular arrhythmia triggering during implantable cordioverter-defibrillator (ICD) implantation. Material and metods. The study group consisted of 21 patients, aged 63.0+/-8.0 years; EF was 38.0+/-12.8%. Seventeen of them had a history of myocardial infarction and 4 had non-ischemic cardiomyopathy. The reason for ICD implantation were secondary prevention due to nonfatal cardiac arrest caused by VF/VT in nineteen patients and in two patients ICD was implanted because of unexplained syncope and low EF (protocol of 50 Hz BURST and T SHOCK was applied. After ICD implantation the following tests were performed: ECG with HR, QRS and QTc evaluation, 24-hour ECG Holter monitoring with HRV assessment and MTWA evaluation during treadmill exercise test. Results. In the group with VT/VF induced by less aggressive protocol (EPS), group I (n = 10) MTWA was present in nine patients, in one the result of MTWA was indeterminate. In the group with VT/VF induced by more aggressive protocol, group II (n = 11) MTWA was present in four patients, indeterminate in four and absent in three. There was a significant (p = 0.017) difference between group I and II in the frequency of positive result of MTWA. There were no differences between the two groups according to time domain parameters of HRV such as SDNN, RMSSD and PNN50 and QTc. There was a significant difference between the two groups in time duration of QRS complexes, 118.9+/-14.7 vs. 105.6+/-11.5 accordingly (p more easily inducible by electrophysiologic study during ICD implantation. It is easier to induce ventricular arrhythmia when QRS complexes are wider, irrelevant to left ventricular dysfunction and autonomic function of the heart.

  3. [Rehabilitation of patients with cardiac pacemakers and implanted cardioverter-defibrillators: recommendations for training, physiotherapeutic procedures and re-employment].

    Science.gov (United States)

    Reibis, R K; Kamke, W; Langheim, E; Völler, H

    2010-04-01

    Rehabilitation of patients with cardiac pacemakers (CP) or implantable cardioverter defibrillators (ICD) comprises secondary prevention of underlying cardiac disease, conditioning training activities and psychological education and includes furthermore the assessment of aggregate function, detection of any device malfunction as well as the return to work efforts. The extent to which the physical activities can be permitted is determined by both cardiopulmonary capacity and the primary arrhythmic indication. Under consideration of upper frequency limit, left ventricular dysfunction and the avoidance of mechanical exposure on device can and leads, an individually designed training programme is acceptable even on a high load level. Likewise, electrotherapeutic procedures due to musculoskeletal pain syndrome are not generally contraindicated, if differentiated limitations are respected. Beside the assessment of aggregate function and, if necessary, parameter optimization, psychologic intervention programs play an important role particularly in ICD-patients and can be utilized as an additive therapeutic module. Personalized recommendations for driving with an ICD are determined by the time interval since idex arrhythmia and the rhythmological risk profile as well as by the motor vehicle class. The return to work rate of CP and ICD patients is resumably influenced by the underlying cardiac disease and to a lesser extend by the implanted device. Except industrial jobs the risk of electromagnetic interference during the working process is low and can be objected by working place analysis including noise field measurement. Thus cardiac of CP and ICD patients should be used to a large extend for the recovery of individual physical and psychological integrity as well as for the organisation of reemployment.

  4. Prevalence, correlates, and temporal trends in antiarrhythmic drug use at discharge after implantable cardioverter defibrillator placement (from the National Cardiovascular Data Registry [NCDR]).

    Science.gov (United States)

    Dev, Sandesh; Peterson, Pamela N; Wang, Yongfei; Curtis, Jeptha P; Varosy, Paul D; Masoudi, Frederick A

    2014-01-15

    Patients with implantable cardioverter defibrillators (ICDs) can require antiarrhythmic drugs to manage arrhythmias and prevent device shocks. We sought to determine the prevalence, clinical correlates, and institutional variation in the use of antiarrhythmic drugs over time after ICD implantation. From the ICD Registry (2006 to 2011), we analyzed the trends in the use of antiarrhythmic agents prescribed at hospital discharge for patients undergoing first-time ICD placement. The patient, provider, and facility level variables associated with antiarrhythmic use were determined using multivariate logistic regression models. A median odds ratio was calculated to assess the hospital-level variation in the use of antiarrhythmic drugs. Of the cohort (n = 500,995), 15% had received an antiarrhythmic drug at discharge. The use of class III agents increased modestly (13.9% to 14.9%, p <0.01). Amiodarone was the most commonly prescribed drug (82%) followed by sotalol (10%). Among the subgroups, the greatest increase in prescribing was for patients who had received a secondary prevention ICD (26% in 2006% and 30% in 2011, p <0.01) or with a history of ventricular tachycardia (23% to 27%, p <0.01). The median odds ratio for antiarrhythmic prescription was 1.45, indicating that 2 randomly selected hospitals would have had a 45% difference in the odds of treating identical patients with an antiarrhythmic drug. In conclusion, antiarrhythmic drug use, particularly class III antiarrhythmic drugs, is common among ICD recipients at hospital discharge and varies by hospital, suggesting an influence from local treatment patterns. The observed hospital variation suggests a role for augmentation of clinical guidelines regarding the use of antiarrhythmic drugs for patients undergoing implantation of an ICD. Published by Elsevier Inc.

  5. Preparing for ICD-10 and conforming your documentation.

    Science.gov (United States)

    Buckholtz, Rhonda

    2013-01-01

    There are many unknowns right now with the implementation of ICD-10-CM. However, tackling a few obstacles early on along with a keen sense of ICD-10 awareness will put you ahead of the game and able to continue on after October 1, 2014. Waiting until the last minute in hopes of delays will surely hinder the financial stability of your practice. This article will take you through what is needed for ICD-10 implementation and help you jumpstart your efforts.

  6. Neurodevelopmental Disorders (ASD and ADHD): DSM-5, ICD-10, and ICD-11.

    Science.gov (United States)

    Doernberg, Ellen; Hollander, Eric

    2016-08-01

    Neurodevelopmental disorders, specifically autism spectrum disorder (ASD) and attention-deficit/hyperactivity disorder (ADHD) have undergone considerable diagnostic evolution in the past decade. In the United States, the current system in place is the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5), whereas worldwide, the International Statistical Classification of Diseases and Related Health Problems, Tenth Revision (ICD-10) serves as a general medical system. This review will examine the differences in neurodevelopmental disorders between these two systems. First, we will review the important revisions made from the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) to the DSM-5, with respect to ASD and ADHD. Next, we will cover the similarities and differences between ASD and ADHD classification in the DSM-5 and the ICD-10, and how these differences may have an effect on neurodevelopmental disorder diagnostics and classification. By examining the changes made for the DSM-5 in 2013, and critiquing the current ICD-10 system, we can help to anticipate and advise on the upcoming ICD-11, due to come online in 2017. Overall, this review serves to highlight the importance of progress towards complementary diagnostic classification systems, keeping in mind the difference in tradition and purpose of the DSM and the ICD, and that these systems are dynamic and changing as more is learned about neurodevelopmental disorders and their underlying etiology. Finally this review will discuss alternative diagnostic approaches, such as the Research Domain Criteria (RDoC) initiative, which links symptom domains to underlying biological and neurological mechanisms. The incorporation of new diagnostic directions could have a great effect on treatment development and insurance coverage for neurodevelopmental disorders worldwide.

  7. ICDS database: interrupted CoDing sequences in prokaryotic genomes.

    Science.gov (United States)

    Perrodou, Emmanuel; Deshayes, Caroline; Muller, Jean; Schaeffer, Christine; Van Dorsselaer, Alain; Ripp, Raymond; Poch, Olivier; Reyrat, Jean-Marc; Lecompte, Odile

    2006-01-01

    Unrecognized frameshifts, in-frame stop codons and sequencing errors lead to Interrupted CoDing Sequence (ICDS) that can seriously affect all subsequent steps of functional characterization, from in silico analysis to high-throughput proteomic projects. Here, we describe the Interrupted CoDing Sequence database containing ICDS detected by a similarity-based approach in 80 complete prokaryotic genomes. ICDS can be retrieved by species browsing or similarity searches via a web interface (http://www-bio3d-igbmc.u-strasbg.fr/ICDS/). The definition of each interrupted gene is provided as well as the ICDS genomic localization with the surrounding sequence. Furthermore, to facilitate the experimental characterization of ICDS, we propose optimized primers for re-sequencing purposes. The database will be regularly updated with additional data from ongoing sequenced genomes. Our strategy has been validated by three independent tests: (i) ICDS prediction on a benchmark of artificially created frameshifts, (ii) comparison of predicted ICDS and results obtained from the comparison of the two genomic sequences of Bacillus licheniformis strain ATCC 14580 and (iii) re-sequencing of 25 predicted ICDS of the recently sequenced genome of Mycobacterium smegmatis. This allows us to estimate the specificity and sensitivity (95 and 82%, respectively) of our program and the efficiency of primer determination.

  8. Dollars and sense: Mitigating budget risk for ICD-10.

    Science.gov (United States)

    Newell, Lucy Mancini; DeSilva, Joseph J

    2013-02-01

    The extended deadline for ICD-10 implementation is time that should not be wasted. Healthcare leaders should keep three things in mind: CFOs should approach the effort knowing the costs of ICD-10 implementation will be high and spread over multiple budget years. Training, productivity, and contractual issues are among key areas that will be challenged by ICD-10 implementation. Healthcare finance leaders should work to improve cash-on-hand and cash reserves prior to the ICD-10 deadline to ensure liquidity post-compliance.

  9. A shocking past: a walk through generations of defibrillation development.

    Science.gov (United States)

    Gutbrod, Sarah R; Efimov, Igor R

    2014-05-01

    Defibrillation is one of the most successful and widely recognized applications of electrotherapy. Yet the historical road to its first successful application in a patient and the innovative adaptation to an implantable device is marred with unexpected turns, political and personal setbacks, and public and scientific condemnation at each new idea. Driven by dedicated scientists and ever-advancing creative applications of new technologies, from electrocardiography to high density mapping and computational simulations, the field of defibrillation persevered and continued to evolve to the life-saving tool it is today. In addition to critical technological advances, the history of defibrillation is also marked by the plasticity of the theory of defibrillation. The advancing theories of success have propelled the campaign for reducing the defibrillation energy requirement, instilling hope in the development of a painless and harmless electrical defibrillation strategy.

  10. Serum-Based Oxylipins Are Associated with Outcomes in Primary Prevention Implantable Cardioverter Defibrillator Patients

    Science.gov (United States)

    Zhang, Yiyi; Guallar, Eliseo; Blasco-Colmenares, Elena; Harms, Amy C.; Vreeken, Rob J.; Hankemeier, Thomas; Tomaselli, Gordon F.; Cheng, Alan

    2016-01-01

    Introduction Individuals with systolic heart failure are at risk of ventricular arrhythmias and all-cause mortality. Little is known regarding the mechanisms underlying these events. We sought to better understand if oxylipins, a diverse class of lipid metabolites derived from the oxidation of polyunsaturated fatty acids, were associated with these outcomes in recipients of primary prevention implantable cardioverter defibrillators (ICDs). Methods Among 479 individuals from the PROSE-ICD study, baseline serum were analyzed and quantitatively profiled for 35 known biologically relevant oxylipin metabolites. Associations with ICD shocks for ventricular arrhythmias and all-cause mortality were evaluated using Cox proportional hazards models. Results Six oxylipins, 17,18-DiHETE (HR = 0.83, 95% CI 0.70 to 0.99 per SD change in oxylipin level), 19,20-DiHDPA (HR = 0.79, 95% CI 0.63 to 0.98), 5,6-DiHETrE (HR = 0.73, 95% CI 0.58 to 0.91), 8,9-DiHETrE (HR = 0.76, 95% CI 0.62 to 0.95), 9,10-DiHOME (HR = 0.81, 95% CI 0.65 to 1.00), and PGF1α (HR = 1.33, 95% CI 1.04 to 1.71) were associated with the risk of appropriate ICD shock after multivariate adjustment for clinical factors. Additionally, 4 oxylipin-to-precursor ratios, 15S-HEPE / FA (20:5-ω3), 17,18-DiHETE / FA (20:5-ω3), 19,20-DiHDPA / FA (20:5-ω3), and 5S-HEPE / FA (20:5-ω3) were positively associated with the risk of all-cause mortality. Conclusion In a prospective cohort of patients with primary prevention ICDs, we identified several novel oxylipin markers that were associated with appropriate shock and mortality using metabolic profiling techniques. These findings may provide new insight into the potential biologic pathways leading to adverse events in this patient population. PMID:27281224

  11. Association of air pollution with increased incidence of ventricular tachyarrhythmias recorded by implantable cardioverter defibrillators: Vulnerable patients to air pollution.

    Science.gov (United States)

    Kim, In-Soo; Sohn, Jungwoo; Lee, Seung-Jun; Park, Jin-Kyu; Uhm, Jae-Sun; Pak, Hui-Nam; Lee, Moon-Hyoung; Kim, Changsoo; Joung, Boyoung

    2017-08-01

    This study investigated the acute effects of exposure to air pollution on ventricular tachyarrhythmias (VTAs) in an East Asian population. The association between air pollution and VTA has not yet been studied in an East Asian country affected by the Asian dust phenomenon, which worsens air quality. The study cohort consisted of 160patients with implantable cardioverter defibrillator (ICD) devices in the Seoul metropolitan area who were followed for 5.5±3.8years. We used ICD records of VTAs and matched these with hourly measurements of air pollutant concentrations and meteorological data. Fine particle mass and gaseous air pollution plus temperature and relative humidity were measured hourly during the study period. During the study period, 1064 VTA events including 204 instances of ventricular fibrillation (VF) were observed. We found a statistically significant association between overall VTA events and SO2 (lag 24h; OR 1.49, 95%CI 1.16-1.92, p=0.002), PM10 (lag 2h; OR 2.56, 95%CI 2.03-3.23, pair pollution and VTA were observed in a metropolitan area of an East Asian country. Exposures to SO2, PM10, NO2, and CO were significantly associated with VTAs in ICD patients with SHD. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. A pilot study of a mindfulness based stress reduction program in adolescents with implantable cardioverter defibrillators or pacemakers.

    Science.gov (United States)

    Freedenberg, Vicki A; Thomas, Sue A; Friedmann, Erika

    2015-04-01

    Adolescents with implantable cardioverter defibrillators (ICDs) or pacemakers (PMs) face unique challenges that can cause psychosocial distress. Psychosocial interventions are effective for adults with cardiac devices and could potentially impact adolescents' adjustment to these devices. Mindfulness Based Stress Reduction (MBSR) is a structured psycho-educational program that includes meditation, yoga, and group support and has been studied extensively among adults. This study examined the feasibility of the MBSR program for adolescents with ICDs/PMs, a population previously unexamined in the research literature. The participants completed measures of anxiety and depression (Hospital Anxiety and Depression Scale) and coping (Responses to Stress Questionnaire) at baseline and after the six-session MBSR intervention. Mean age of the cohort (n = 10) was 15 ± 3 years, 6 were male, 6 had a PM, and 4 had an ICD. Feasibility was demonstrated by successful recruitment of 10 participants, 100 % participation and completion. Anxiety decreased significantly following the intervention, with a large effect size, t[9] = 3.67, p MBSR interventions in adolescents with high-risk cardiac diagnoses.

  13. Gender differences in appropriate shocks and mortality among patients with primary prophylactic implantable cardioverter-defibrillators: Systematic review and meta-analysis

    CERN Document Server

    Conen, David; Röver, Christian; Bergau, Leonard; Muñoz, Pascal; Wijers, Sofieke; Sticherling, Christian; Zabel, Markus; Friede, Tim

    2016-01-01

    BACKGROUND: Some but not all prior studies have shown that women receiving a primary prophylactic implantable cardioverter defibrillator (ICD) have a lower risk of death and appropriate shocks than men. PURPOSE: To evaluate the effect of gender on the risk of appropriate shock, all-cause mortality and inappropriate shock in contemporary studies of patients receiving a primary prophylactic ICD. DATA SOURCE: PubMed, LIVIVO, Cochrane CENTRAL between 2010 and 2016. STUDY SELECTION: Studies providing at least 1 gender-specific risk estimate for the outcomes of interest. DATA EXTRACTION: Abstracts were screened independently for potentially eligible studies for inclusion. Thereby each abstract was reviewed by at least two authors. DATA SYNTHESIS: Out of 680 abstracts retained by our search strategy, 20 studies including 46'657 patients had gender-specific information on at least one of the relevant endpoints. Mean age across the individual studies varied between 58 and 69 years. The proportion of women enrolled ran...

  14. Extended detection time to reduce shocks is safe in secondary prevention patients : The secondary prevention substudy of PainFree SST

    NARCIS (Netherlands)

    Sterns, Laurence D; Meine, Mathias; Kurita, Takashi; Meijer, Albert; Auricchio, Angelo; Ando, Kenji; Leng, Charles T; Okumura, Ken; Sapp, John L; Brown, Mark L; Lexcen, Daniel R; Gerritse, Bart; Schloss, Edward J

    2016-01-01

    BACKGROUND: Prolonged ventricular fibrillation (VF) detection has been shown to reduce implantable cardioverter-defibrillator (ICD) therapies and improve prognosis in primary prevention ICD patients. Data in secondary prevention patients are limited. OBJECTIVE: The PainFree SST secondary prevention

  15. Fast Electrocardiogram Amplifier Recovery after Defibrillation Shock

    Directory of Open Access Journals (Sweden)

    Ivan Dotsinsky

    2005-04-01

    Full Text Available A procedure for fast ECG amplifier recovery after defibrillation shocks was developed and simulated in the MATLAB environment. Exponentially decaying post-shock voltages have been recorded. Signals from the AHA database are taken and mixed with the recorded exponential disturbances. The algorithm applies moving averaging (comb filter on the compound input signal, thereby obtaining the samples of the disturbance. They are currently subtracted from the input signal. The results obtained show that its recovery is practically instantaneous.

  16. Legal aspects in implantable defibrillator extraction.

    Science.gov (United States)

    D'Ovidio, C; Costantini, S; Vellante, P; Carnevale, A

    2013-10-01

    At the Institute of Legal Medicine in Chieti, a case of iatrogenic superior vena cava perforation was observed during laser extraction of an infected biventricular implantable cardiac defibrillator. The presentation of this particular case represented a starting point for studying the occurrence of similar complications in literature, since their knowledge and understanding should induce resolution of any organisation problems, aid in increasing physicians' training and impose the availability of cardiac surgeons during such operations.

  17. Athletic participation in the young patient with an implantable cardioverter-defibrillator.

    Science.gov (United States)

    Lampert, Rachel; Law, Ian

    2017-01-01

    The decision of whether to allow a young patient with an implantable cardioverter-defibrillator to continue to participate in sports is complex and multi-factorial. The positive physical and psychosocial impact of sports participation must be weighed against the potential adverse events associated with implantable cardioverter-defibrillators. Arrhythmias appear to be more prevalent in athletes and occur more frequently during physical activity or competition/practice, but there is growing evidence that device therapy is effective in athletes across a wide range of competitive sports. Failure of a device to convert a life-threatening arrhythmia, major injury from a shock, and increased lead failure have thus far not been reported in the prospective Implantable Cardioverter-Defibrillator Sports Registry, but follow-up remains relatively short. Thoughtful consideration of disease state, arrhythmia risk, and the potential dangers of device therapy during the desired sports is imperative before allowing participation. Frank discussion with children and families regarding the possibility of shocks during sports, as well as at other times, is imperative. Ongoing and future studies will help guide these decisions.

  18. Impact of the Transition to ICD-10 on Medicare Payment

    Data.gov (United States)

    U.S. Department of Health & Human Services — Although the transition from the ICD-9-CM to the ICD-10 version of MS-DRGs resulted in 1.68 percent of the patients being assigned to a different MS-DRG, payment...

  19. Identification of ICD Codes Suggestive of Child Maltreatment

    Science.gov (United States)

    Schnitzer, Patricia G.; Slusher, Paula L.; Kruse, Robin L.; Tarleton, Molly M.

    2011-01-01

    Objective: In order to be reimbursed for the care they provide, hospitals in the United States are required to use a standard system to code all discharge diagnoses: the International Classification of Disease, 9th Revision, Clinical Modification (ICD-9). Although ICD-9 codes specific for child maltreatment exist, they do not identify all…

  20. Deriving ICD-11 personality disorder domains from DSM-5 traits

    DEFF Research Database (Denmark)

    Bach, Bo; Sellbom, Martin; Kongerslev, Mickey

    2017-01-01

    OBJECTIVE: The personality disorder domains proposed for the ICD-11 comprise Negative Affectivity, Detachment, Dissociality, Disinhibition, and Anankastia, which are reasonably concordant with the higher-order trait domains in the Alternative DSM-5 Model for Personality Disorders. METHOD: We...... in the proposed ICD-11 five-domain structure as well as other recognizable higher-order models of personality and psychopathology. Model fits revealed that the five proposed ICD-11 personality disorder domains were satisfactorily resembled, and replicated in the independent US sample. CONCLUSION: The proposed ICD......-11 personality disorder domains can be accurately described using designated traits from the DSM-5 personality trait system. A scoring algorithm for the ICD-11 personality disorder domains is provided in appendix....

  1. Selective left ventricular sensing lead implantation to overcome undersensing of ventricular fibrillation during implantable cardioverter defibrillator implantation.

    Science.gov (United States)

    Steinberg, Christian; Philippon, François; O'Hara, Gilles; Molin, Franck

    2013-06-01

    Accurate sensing of malignant arrhythmia is critical for the appropriate delivery of therapy from implantable cardioverter defibrillators, and undersensing of ventricular tachyarrhythmias can have catastrophic consequences. Here, we present an unusual case of ventricular fibrillation undersensing from the right ventricular lead at multiple different implantation sites because of very low amplitude voltage signals during induced ventricular fibrillation. A left ventricular sensing electrode was implanted to allow correct sensing and therapy delivery.

  2. Predictive value of programmed ventricular stimulation in patients with ischaemic cardiomyopathy: implications for the selection of candidates for an implantable defibrillator.

    Science.gov (United States)

    De Ferrari, Gaetano M; Rordorf, Roberto; Frattini, Folco; Petracci, Barbara; De Filippo, Paolo; Landolina, Maurizio

    2007-12-01

    The present study assessed the role of programmed ventricular stimulation (PVS) in risk stratification of patients with ischaemic cardiomyopathy (ICM), candidates for implantable cardioverter-defibrillator (ICD). Consecutive patients with ICM and LVEF < or = 40% (n = 106, age 61 +/- 7 years, LVEF 27 +/- 7%) underwent PVS. This was considered positive in case of inducibility of monomorphic ventricular tachycardia (VT) with < or =3 extrastimuli; polymorphic VT, ventricular fibrillation (VF), and fast monomorphic VT (CL < or = 230 ms) with < or =2 extrastimuli. Primary end-point was the combination of arrhythmic death and VF requiring ICD shock. Forty-nine patients (46%) were inducible at PVS; 74 (70%) were implanted with ICD. During a 24-month follow-up, the primary end-point occurred more frequently in positive PVS patients among the overall population, among patients with LVEF < or = 30% (n = 80) and among patients with an ICD. The negative predictive value of PVS was 96% in each group. In the overall population, both PVS (HR 7.32, 95% CI 1.6-32) and LVEF (HR 4.59, 95% CI 1.6-13) predicted the primary end-point. PVS may still have a role in predicting the arrhythmic risk in patients with ICM. A negative PVS identifies a subgroup with a very low risk of arrhythmic events even in patients with LVEF < or = 30%.

  3. Genoplivning med automatisk ekstern defibrillator på hospital

    DEFF Research Database (Denmark)

    Løfgren, Bo; Wahlgreen, Claus; Hoffmann, Anne Mette;

    2009-01-01

    Early defibrillation is a determinant of survival in cardiac arrest. We report a Danish case of successful in-hospital resuscitation using an automated external defibrillator (AED). This case illustrates important aspects of implementation of in-hospital use of an AED, i.e. location of the AED, e...

  4. Leveraging the NLM map from SNOMED CT to ICD-10-CM to facilitate adoption of ICD-10-CM.

    Science.gov (United States)

    Cartagena, F Phil; Schaeffer, Molly; Rifai, Dorothy; Doroshenko, Victoria; Goldberg, Howard S

    2015-05-01

    Develop and test web services to retrieve and identify the most precise ICD-10-CM code(s) for a given clinical encounter. Facilitate creation of user interfaces that 1) provide an initial shortlist of candidate codes, ideally visible on a single screen; and 2) enable code refinement. To satisfy our high-level use cases, the analysis and design process involved reviewing available maps and crosswalks, designing the rule adjudication framework, determining necessary metadata, retrieving related codes, and iteratively improving the code refinement algorithm. The Partners ICD-10-CM Search and Mapping Services (PI-10 Services) are SOAP web services written using Microsoft's.NET 4.0 Framework, Windows Communications Framework, and SQL Server 2012. The services cover 96% of the Partners problem list subset of SNOMED CT codes that map to ICD-10-CM codes and can return up to 76% of the 69,823 billable ICD-10-CM codes prior to creation of custom mapping rules. We consider ways to increase 1) the coverage ratio of the Partners problem list subset of SNOMED CT codes and 2) the upper bound of returnable ICD-10-CM codes by creating custom mapping rules. Future work will investigate the utility of the transitive closure of SNOMED CT codes and other methods to assist in custom rule creation and, ultimately, to provide more complete coverage of ICD-10-CM codes. ICD-10-CM will be easier for clinicians to manage if applications display short lists of candidate codes from which clinicians can subsequently select a code for further refinement. The PI-10 Services support ICD-10 migration by implementing this paradigm and enabling users to consistently and accurately find the best ICD-10-CM code(s) without translation from ICD-9-CM. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Remote monitoring of ICDs and CRTs

    Directory of Open Access Journals (Sweden)

    Niraj Varma

    2013-06-01

    Full Text Available Cardiac implantable electronic devices are increasing in prevalence and functionality. Post-implant follow-up is important for monitoring both device function and patient condition. However, practice is inconsistent. For example, ICD follow-up schedules vary from 3 months to yearly according to facility and physician preference and availability of resources. Recommended follow-up schedules impose significant burden. Importantly, no surveillance occurs between follow-up visits. In contrast, implantable devices with automatic remote monitoring capability provide a means for performing constant surveillance, with the ability to identify salient problems rapidly. Results from large randomized prospective trials of all types of CIEDs from different manufacturers, and conducted in different countries, consistently indicate superior performance to conventional care for achieving the current follow-up goals of patient retention and early problem discovery, improving patient safety and convenience, yet promoting clinic efficiencies. Thus, automatic remote home monitoring is a transforming technology in the evolution of CIEDs, and is poised for remarkable gains in disease management.

  6. Closing the ICD-l0 revenue gap.

    Science.gov (United States)

    Carr, Kimberly Janet

    2013-06-01

    Hospitals can improve clinical documentation under ICD-10 by implementing three strategies: Bring clinical documentation improvement (CDI) specialists and coders together for daily or weekly communications to improve documentation quality, processes, and outcomes. Encourage CDI specialists to engage in direct, one-on-one conversations with physicians or generate queries, whether paper or EHR-based, to clarify missing or unclear documentation to promote better overall clinical documentation outcomes. Assess ICD-10 hot spots for documentation gaps to mitigate risk of lost revenue under ICD-10.

  7. Clinical and psychological impact of prophylactic implantable cardioverter-defibrillators in a community heart failure population.

    LENUS (Irish Health Repository)

    Arnous, S

    2012-02-01

    AIMS: ICD implantation for primary prevention of sudden cardiac death in patients with left ventricular systolic dysfunction (ejection fraction <\\/= 35%) has increased since the publication of the SCD-HEFT and MADIT-II data. The aim of this study is to examine the effectiveness and safety of prophylactic ICD use in a community heart failure population and to assess the impact on patient\\'s quality of life. METHODS AND RESULTS: Seventy-one ICDs were inserted between the years 2002 and 2006. The mean follow-up from time of insertion was 24 +\\/- 11 months. Eighteen patients (25%) had potentially life-saving therapy. Seven (10%) patients received inappropriate shocks. Complications were encountered in five patients (7%). CONCLUSION: In a community heart failure population, prophylactic ICD implantation is associated with a high incidence of life-saving therapy, a low complication rate and a high level of tolerability. These data indicate translation of clinical trial benefits to the general heart failure population.

  8. Cardiac embolism after implantable cardiac defibrillator shock in non-anticoagulated atrial fibrillation: The role of left atrial appendage occlusion.

    Science.gov (United States)

    Freixa, Xavier; Andrea, Rut; Martín-Yuste, Victoria; Fernández-Rodríguez, Diego; Brugaletta, Salvatore; Masotti, Mónica; Sabaté, Manel

    2014-04-26

    Cardioembolic events are one of the most feared complications in patients with non-valvular atrial fibrillation (NVAF) and a formal contraindication to oral anticoagulation (OAC). The present case report describes a case of massive peripheral embolism after an implantable cardiac defibrillator (ICD) shock in a patient with NVAF and a formal contraindication to OAC due to previous intracranial hemorrhage. In order to reduce the risk of future cardioembolic events, the patient underwent percutaneous left atrial appendage (LAA) occlusion. A 25 mm Amplatzer™ Amulet was implanted and the patient was discharged the following day without complications. The potential risk of thrombus dislodgement after an electrical shock in patients with NVAF and no anticoagulation constitutes a particular scenario that might be associated with an additional cardioembolic risk. Although LAA occlusion is a relatively new technique, its usage is rapidly expanding worldwide and constitutes a very valid alternative for patients with NVAF and a formal contraindication to OAC.

  9. Estudo clínico de um sistema cardioversor-desfibrilador implantável que apresenta limiares de desfibrilação baixos usando eletrodos de estrutura fractal Clinical studies of an implantable cardioversor - defibrillators system providing low defibrillation thresholds as well as high signal amplitudes due to fractal coated electrodes

    Directory of Open Access Journals (Sweden)

    Fernando A. LUCCHESE

    1999-01-01

    Full Text Available Em função do contínuo desenvolvimento tecnológico, a geração atual de cardioversores-desfibriladores implantáveis (CDI garante um alto grau de segurança e eficiência na detecção e reversão de taquiarritmias ventriculares. O presente trabalho sumariza os resultados clínicos obtidos com 1058 CDI de câmara única (Phylax 6, Phylax XM, Biotronik utilizando eletrodo único e tecnologia de carcaça ativa, SPS e Kainox RV (com uma mola intracavitária de choque, SL-ICD e Kainox SL (com duas molas intracavitárias de choque, Biotronik. Na quase totalidade dos pacientes, com exceção de 3 (> 99%, foram obtidos limiares de desfibrilação com baixa energia usando apenas um eletrodo transvenoso. Isto tem permitido substituir o teste de limiar de desfibrilação usual por um teste simples durante o implante, afim de minimizar os riscos associados com repetidas induções de fibrilação e conseqüente extensão do período de anestesia.Due to continuously improved technologies, the present generation of implantable cardioverter-defibrillators (ICD guarantees a high degree of safety and efficacy for detecting and terminating ventricular tachyarrhythmias. This paper summarizes the clinical results obtained with 1058 single-chamber ICD (Phylax 6, Phylax XM, Biotronik employing single-lead and active housing technology (SPS and Kainox RV (single coil, SL-ICD and Kainox SL (double coil, Biotronik. In all but 3 patients (> 99%, reliable low-energy defibrillation was achieved using transvenous leads only. This has led to the trend to replace DFT testing by a short function test during implantation in order to minimize the risks associated with repeated induction of fibrillation and extended anesthesia.

  10. Defibrillation lead placement using a transthoracic transatrial approach in a case without transvenous access due to lack of the right superior vena cava.

    Science.gov (United States)

    Otsuka, Yosuke; Okamura, Hideo; Sato, Syunsuke; Nakajima, Ikutaro; Ishibashi, Kohei; Miyamoto, Kouji; Noda, Takashi; Aiba, Takeshi; Kamakura, Shiro; Kobayashi, Junjiro; Yasuda, Satoshi; Ogawa, Hisao; Kusano, Kengo

    2015-06-01

    A 65-year-old woman with a history of syncope was diagnosed with hypertrophic cardiomyopathy. She had previously undergone mastectomy of the left breast owing to breast cancer. Holter electrocardiogram (ECG) and monitor ECG revealed sick sinus syndrome (Type II) and non-sustained ventricular tachycardia. Sustained ventricular tachycardia and ventricular fibrillation were induced in an electrophysiological study. Although the patient was eligible for treatment with a dual chamber implantable cardioverter defibrillator (ICD), venography revealed lack of the right superior vena cava (R-SVC). Lead placement from the left subclavian vein would have increased the risk of lymphedema owing to the patient׳s mastectomy history. Consequently, the defibrillation lead was placed in the right ventricle by direct puncture of the right auricle through the tricuspid valve. The atrial lead was sutured to the atrial wall, and the postoperative course was unremarkable. Defibrillation lead placement using a transthoracic transatrial approach can be an alternative method in cases where a transvenous approach for lead placement is not feasible.

  11. Development of Pacing, Electrophysiology and Defibrillation in India

    Directory of Open Access Journals (Sweden)

    Mohan Nair

    2002-04-01

    rheumatic heart disease is generally of long duration and affects a younger population. Control of Rate versus Rhythm in Rheumatic Atrial Fibrillation Trial -‘CRRAFT’ conducted at Mumbai has documented the effectiveness of amiodarone in the treatment of rheumatic atrial fibrillation. Surgical RF pulmonary vein isolation using Thermaline Multi-Electrode Catheter [EP Technologies] has been done in 27 patients with rheumatic atrial fibrillation of more than one year duration. Lesions were as follows: bilateral pulmonary vein isolation, isolation of the left atrial appendage and connection lesion between left atrial appendage and pulmonary veins.Prof. K.K. Talwar, AIIMS, New Delhi and Dr. T.S. Kler, Escorts Heart Institute & Research Centre, New Delhi were the first to implant Implantable Cardioverter Defibrillators (ICD in India. Current annual ICD implantation rates stand at 60 per year.

  12. Patient satisfaction and suggestions for improvement of remote ICD monitoring

    DEFF Research Database (Denmark)

    Petersen, Helen Høgh; Larsen, Mie Christa Jensen; Nielsen, Olav Wendelboe

    2012-01-01

    -up clinic at Rigshospitalet using CareLink® (Medtronic) remote follow-up, who had made =2 transmissions, received a questionnaire. RESULTS: Three hundred eighty-five patients (81.2%) answered. Mean time with ICD was 56¿±¿45 months and mean age was 62¿±¿13 years; 80% was male. Diagnosis related to ICD...

  13. Design of the evolution of management strategies of heart failure patients with implantable defibrillators (EVOLVO study to assess the ability of remote monitoring to treat and triage patients more effectively

    Directory of Open Access Journals (Sweden)

    Campana Carlo

    2009-06-01

    Full Text Available Abstract Background Heart failure patients with implantable defibrillators (ICD frequently visit the clinic for routine device monitoring. Moreover, in the case of clinical events, such as ICD shocks or alert notifications for changes in cardiac status or safety issues, they often visit the emergency department or the clinic for an unscheduled visit. These planned and unplanned visits place a great burden on healthcare providers. Internet-based remote device interrogation systems, which give physicians remote access to patients' data, are being proposed in order to reduce routine and interim visits and to detect and notify alert conditions earlier. Methods The EVOLVO study is a prospective, randomized, parallel, unblinded, multicenter clinical trial designed to compare remote ICD management with the current standard of care, in order to assess its ability to treat and triage patients more effectively. Two-hundred patients implanted with wireless-transmission-enabled ICD will be enrolled and randomized to receive either the Medtronic CareLink® monitor for remote transmission or the conventional method of in-person evaluations. The purpose of this manuscript is to describe the design of the trial. The results, which are to be presented separately, will characterize healthcare utilizations as a result of ICD follow-up by means of remote monitoring instead of conventional in-person evaluations. Trial registration ClinicalTrials.gov: NCT00873899

  14. Improving Defibrillation Efficiency in Area Schools.

    Science.gov (United States)

    Thomas, Vincent C; Shen, Jay J; Stanley, Ramona; Dahlke, Jeffrey; McPartlin, Sheri; Row, Lynn

    2016-07-01

    Sudden cardiac arrest (SCA) in the young is a rare event but the effects can be devastating. We sought to identify variables that would lead to an improvement in time to defibrillation (TDFB), a previously noted factor significantly influencing survival from cardiac arrest. During the 2013-2014 academic year, the Clark county school district performed quarterly drills to practice the coordinated automated external defibrillator (AED) response. Variables including school, AED carrier, and drill characteristics were measured to determine influence on TDFB. Schools were grouped by TDFB at a cutoff of three minutes. Characteristics were sought for schools with TDFB below three minutes. A mixed regression model taking into account repeated measures was created to determine which variables influenced TDFB. Time to overhead announcement, distance of AED from drill site, and time to setup AED were the variables influencing TDFB with statistical significance (P <.01). This study supports the notion of early recognition, announcement, and close proximity to an AED during a SCA to ensure an early TDFB. These results are consistent with basic life support and the chain of survival tenets of the American Heart Association. © 2016 Wiley Periodicals, Inc.

  15. Genoplivning med automatisk ekstern defibrillator på hospital

    DEFF Research Database (Denmark)

    Løfgren, Bo; Wahlgreen, Claus; Hoffmann, Anne Mette

    2009-01-01

    Early defibrillation is a determinant of survival in cardiac arrest. We report a Danish case of successful in-hospital resuscitation using an automated external defibrillator (AED). This case illustrates important aspects of implementation of in-hospital use of an AED, i.e. location of the AED......, education of the staff, systematic registration and data collection and technical aspects of AED use. If in-hospital AED implementation is carefully executed, its use may provide a safe and effective way of obtaining early defibrillation. Udgivelsesdato: 2009-Jan-26...

  16. [ILCOR recommendation on signage of automated external defibrillators (AEDs)].

    Science.gov (United States)

    Truhlár, A

    2010-05-01

    Early defibrillation is a determinant of survival in both out-of-hospital and in-hospital cardiac arrests from ventricular fibrillation and pulseless ventricular tachycardia. The review summarizes importance of early defibrillation with automated external defibrillators (AED) and presents the International Liaison Committee on Resuscitation (ILCOR) recommendation for universal AED sign. The aim of the recommendation is to unify the AED signs worldwide and to spread the knowledge of this. The public in general, but healthcare professionals particularly, should be able to recognize AED location and use the device immediately in case of cardiac arrest.

  17. The wearable cardioverter-defibrillator: current technology and evolving indications.

    Science.gov (United States)

    Reek, Sven; Burri, Haran; Roberts, Paul R; Perings, Christian; Epstein, Andrew E; Klein, Helmut U

    2016-10-04

    The wearable cardioverter-defibrillator has been available for over a decade and now is frequently prescribed for patients deemed at high arrhythmic risk in whom the underlying pathology is potentially reversible or who are awaiting an implantable cardioverter-defibrillator. The use of the wearable cardioverter-defibrillator is included in the new 2015 ESC guidelines for the management of ventricular arrhythmias and prevention of sudden cardiac death. The present review provides insight into the current technology and an overview of this approach.

  18. Performance of a radiation protection cabin during implantation of pacemakers or cardioverter defibrillators.

    Science.gov (United States)

    Ploux, Sylvain; Ritter, Philippe; Haïssaguerre, Michel; Clementy, Jacques; Bordachar, Pierre

    2010-04-01

    Pacemaker implants are associated with a high cumulative exposure of the operators to radiation. Standard radiation protection with lead aprons is incomplete and the cause of spine disorders. A radiation protection cabin offers complete protection by surrounding the operator, without requiring a lead apron. We randomly and evenly assigned 60 patients undergoing implantations of permanent pacemakers or cardioverter defibrillators (ICD) with (a) a radiation protection cabin (cabin group, n = 30) versus (b) standard protection with a 0.5 mm lead-equivalent apron (control group, n = 30). Radiation exposure was measured using personal electronic dosimeters placed on the thorax, back, and head of the operator. The patient, procedural, and device characteristics of the 2 study groups were similar. All procedures in the cabin group were performed as planned without increase in duration or complication rate compared with the control group. The mean radiation dose to the head, normalized for fluoroscopy duration, was significantly lower in the cabin (0.040 +/- 0.032 microSv/min) than in the control (1.138 +/- 0.560 microSv/min) group (p < 0.0001). The radiation doses to the thorax (0.043 +/- 0.027 vs 0.041 +/- 0.040 microSv/min) and back (0.038 +/- 0.029 vs 0.033 +/- 0.018 microSv/min) in the cabin versus control group (under the apron) were similar. The use of a radiation protection cabin markedly decreased the exposure of the operator to radiation, and eliminated the need to wear a lead apron, without increasing the procedural time or complication rate during implantation of pacemaker and ICD.

  19. Magnetic Resonance Imaging in Nondependent Pacemaker Patients with Pacemakers and Defibrillators with a Nearly Depleted Battery.

    Science.gov (United States)

    Okamura, Hideo; Padmanabhan, Deepak; Watson, Robert E; Dalzell, Connie; Acker, Nancy; Jondal, Mary; Romme, Abby L; Cha, Yong-Mei; Asirvatham, Samuel J; Felmlee, Joel P; Friedman, Paul A

    2017-05-01

    Magnetic resonance imaging (MRI) in patients with non-MRI-conditional cardiac implantable electronic devices (CIEDs) has been shown to be safe when performed under closely monitored protocols. However, the safety of MRI in patients with devices with a nearly depleted battery has not been reported. Prospective data were collected between January 2008 and May 2015 in patients with non-MRI-conditional CIEDs undergoing clinically indicated MRI under institutional protocol. Patients who were pacemaker dependent were excluded. Patients whose devices were at elective replacement indicator (ERI) at the time of MRI or close to ERI (ERI or replacement for battery depletion within 3 months of scan) were identified through database review and analyzed for clinical events. MRI scans (n = 569) were performed in 442 patients. Of these, we identified 13 scans performed with a nearly depleted battery in nine patients. All scans with implantable cardioverter defibrillators (ICDs, n = 9) were uneventful. However, two scans with pacemakers close to ERI resulted in a power-on-reset (PoR) event. One scan with a pacemaker close to ERI that was programmed to DOO mode reached ERI during MRI and automatically changed to VVI mode. Additionally, one scan with a pacemaker at ERI did not allow programming. All pacemakers with events were implanted before 2005. Patients with pacemakers and ICDs with a nearly depleted battery can safely undergo MRI when patients are not pacemaker dependent. Attention should be paid because old devices can result in PoR or ERI during MRI, which may lead to oversensing and inhibition of pacing. © 2017 Wiley Periodicals, Inc.

  20. Evaluation and Management of Patients After Implantable Cardioverter-Defibrillator Shock%植入型心律转复除颤器放电后患者的诊治

    Institute of Scientific and Technical Information of China (English)

    Anil K. Gehi; Davendra Mehta; J. Anthony Gomes; 樊颖婕

    2007-01-01

    背景:多项大规模临床试验表明,植入型心律转复除颤器(implantable cardioverterdefibrillator,ICD)能够有效降低部分心脏病患者的死亡率.此后,ICD的植入量大幅增加,非电生理专科医生也因此经常会遇到实施ICD电转复除颤的患者.目的:在接受ICD电转复除颤的患者中评估诊疗策略.证据获取:采用下列医学主题词在PubMed和MEDLINE数据库中检索1990年1月至2006年9月发表的文献:defibrillators,implantable(除颤器,植入型);defibrillators,implantable/adverse effects(除颤器,植入型/不良反应);抗心律失常药物(anti-arrhythmic agents);电除颤(electric countershock);生活质量(quality of life);心动过速治疗(tachycardia therapy);运算法则(algorithm);室性心动过速/诊断(ventricular tachycardia/diagnosis);室上性心动过速/诊断(supraventricular tachycardia/diagnosis).排除病例报告,仅纳入英文文献.参考美国心脏病学会(American College of Cardiology)、美国心脏协会(American Heart Association)、心脏节律学会(Heart Rhythm Society)发布的建议、指南及所附参考文献,获得其他相关文献.证据综合:ICD恰当放电和误放电均有诸多原因.误放电可严重影响患者的生活质量.目前有多种ICD程控技术可有效控制ICD恰当放电和误放电的发生.采用抗心律失常药也能有效减少放电频率.结论:采用有效的ICD程控和抗心律失常药物可在保障ICD急救功能的同时减少ICD放电.对现有各种治疗手段有一个基本的了解是诊治接受ICD放电者的基础.

  1. Circadian variations in the occurrence of ventricular tachyarrhythmias in patients with implantable cardioverter defibrillators.

    Science.gov (United States)

    Kozák, Milan; Krivan, Lubomír; Semrád, Borivoj

    2003-03-01

    A circadian distribution has been demonstrated in episodes of sudden cardiac death, acute myocardial infarction, ventricular premature complexes, heart rate variability, and ventricular tachyarrhythmias. The aim of this study was to evaluate the circadian distribution of ventricular tachyarrhythmia episodes in a population of ICD patients. Data were gathered from 72 patients (55 men, 17 women; mean age 62.7 +/- 12.2 years, mean LVEF 0.0037 +/- 0.0011) with ICDs implanted for standard indications. Patients were followed every 3 months over a mean period of 21 +/- 12.8 months. At each examination, symptoms at arrhythmia onset and perception of ICD therapy were recorded, and the ICD memory was interrogated. During follow-up, 1,023 episodes' of malignant ventricular arrhythmias were detected and effectively terminated, 506 of which were fully analyzed. A morning peak in ventricular tachyarrhythmias was demonstrated between 7:00 and 11:00 AM, and an afternoon peak between 6:00 and 7:00 PM. A significantly lower occurrence of VT was observed at 1:00 AM and between 4:00 and 6:00 AM. A circadian distribution in the occurrence of ventricular tachycardias was found. The three striking features of the data are: the early morning peak (about three hours after waking up), relatively stable incidence throughout waking hours, and decline in incidence in the previous period.

  2. Implementation and impact of ICD-10 (Part II).

    Science.gov (United States)

    Rahmathulla, Gazanfar; Deen, H Gordon; Dokken, Judith A; Pirris, Stephen M; Pichelmann, Mark A; Nottmeier, Eric W; Reimer, Ronald; Wharen, Robert E

    2014-01-01

    The transition from the International Classification of Disease-9(th) clinical modification to the new ICD-10 was all set to occur on 1 October 2015. The American Medical Association has previously been successful in delaying the transition by over 10 years and has been able to further postpone its introduction to 2015. The new system will overcome many of the limitations present in the older version, thus paving the way to more accurate capture of clinical information. The benefits of the new ICD-10 system include improved quality of care, potential cost savings, reduction of unpaid claims, and improved tracking of healthcare data. The areas where challenges will be evident include planning and implementation, the cost to transition, a shortage of qualified coders, training and education of the healthcare workforce, and a loss of productivity when this occurs. The impacts include substantial costs to the healthcare system, but the projected long-term savings and benefits will be significant. Improved fraud detection, accurate data entry, ability to analyze cost benefits with procedures, and enhanced quality outcome measures are the most significant beneficial factors with this change. The present Current Procedural Terminology and Healthcare Common Procedure Coding System code sets will be used for reporting ambulatory procedures in the same manner as they have been. ICD-10-PCS will replace ICD-9 procedure codes for inpatient hospital services. The ICD-10-CM will replace the clinical code sets. Our article will focus on the challenges to execution of an ICD change and strategies to minimize risk while transitioning to the new system. With the implementation deadline gradually approaching, spine surgery practices that include multidisciplinary health specialists have to anticipate and prepare for the ICD change in order to mitigate risk. Education and communication is the key to this process in spine practices.

  3. Implementation and impact of ICD-10 (Part II

    Directory of Open Access Journals (Sweden)

    Gazanfar Rahmathulla

    2014-01-01

    Full Text Available Background: The transition from the International Classification of Disease-9 th clinical modification to the new ICD-10 was all set to occur on 1 October 2015. The American Medical Association has previously been successful in delaying the transition by over 10 years and has been able to further postpone its introduction to 2015. The new system will overcome many of the limitations present in the older version, thus paving the way to more accurate capture of clinical information. Methods: The benefits of the new ICD-10 system include improved quality of care, potential cost savings, reduction of unpaid claims, and improved tracking of healthcare data. The areas where challenges will be evident include planning and implementation, the cost to transition, a shortage of qualified coders, training and education of the healthcare workforce, and a loss of productivity when this occurs. The impacts include substantial costs to the healthcare system, but the projected long-term savings and benefits will be significant. Improved fraud detection, accurate data entry, ability to analyze cost benefits with procedures, and enhanced quality outcome measures are the most significant beneficial factors with this change. Results: The present Current Procedural Terminology and Healthcare Common Procedure Coding System code sets will be used for reporting ambulatory procedures in the same manner as they have been. ICD-10-PCS will replace ICD-9 procedure codes for inpatient hospital services. The ICD-10-CM will replace the clinical code sets. Our article will focus on the challenges to execution of an ICD change and strategies to minimize risk while transitioning to the new system. Conclusion: With the implementation deadline gradually approaching, spine surgery practices that include multidisciplinary health specialists have to anticipate and prepare for the ICD change in order to mitigate risk. Education and communication is the key to this process in spine

  4. Disease-specific quality of life-patient acceptance: racial and gender differences in patients with implantable cardioverter defibrillators.

    Science.gov (United States)

    Wilson, Mary H; Engelke, Martha K; Sears, Samuel F; Swanson, Melvin; Neil, Janice A

    2013-01-01

    Despite its established effectiveness, living with an implantable cardioverter defibrillator (ICD) is associated with ongoing physical and psychosocial distress. Little is known about which factors impact the patients' adjustment to living with the device and whether there are racial or gender differences related to these factors. The purpose of this study was to investigate factors (demographic, clinical, psychosocial, and religiosity) related to patients' ICD acceptance and to examine racial and gender differences in ICD acceptance. A total of 101 ICD patients (mean age, 65 ± 12.8 years, 34% female, 42% African American [AA]) seen in a cardiology clinic between January and August 2010 completed the Florida Patient Acceptance Survey (FPAS), Florida shock anxiety scale, ENRICHD social support instrument, hospital anxiety and depression scale, Hoge Religiosity Scale, and a demographic sheet during their clinic visit. All multiple-item scales demonstrated good internal consistency reliability, with Cronbach α values ranging from .77 to .89. Overall patient acceptance of the ICD was high, with an average FPAS acceptance score of 80.9 on the 0-to-100 point scale. The FPAS subscale scores indicated that the group was very positive about the benefits of having the device (mean, 90.3) and had few body image concerns (mean, 10.6), low device-related distress (mean, 15.6), and moderate return to function scores (mean, 63.0). White ICD participants were more accepting of their device than AA ICD patients were, scoring statistically significantly higher than AA patients on total patient acceptance and return to function and significantly lower than AA patients on device-related distress and shock anxiety. Controlling for ethnicity (β = .10, P = .15), age (β = .01, P = .90), and number of comorbidities (β = .19, P = .003) in a hierarchical multiple regression, shock anxiety (β = .31, P < .001), knowledge of the device (β = .23, P = .001), social support (β = .13, P

  5. A patch in the pectoral position lowers defibrillation threshold.

    Science.gov (United States)

    Karasik, P; Solomon, A; Verdino, R; Moore, H; Rodak, D; Hannan, R; Fletcher, R

    1997-06-01

    Implantable pacemaker cardioverter defibrillators are now available with biphasic waveforms, which have been shown to markedly improve defibrillation thresholds (DFTs). However, in a number of patients the DFT remains high. Also, DFT may increase after implantation, especially if antiarrhythmic drugs are added. We report on the use of a subcutaneous patch in the pectoral position in 15 patients receiving a transvenous defibrillator as a method of easily reducing the DFT. A 660-mm2 patch electrode was placed beneath the generator in a pocket created on the pectoral fascia. The energy required for defibrillation was lowered by 56% on average, and the system impedance was lowered by a mean of 25%. This maneuver allowed all patients to undergo a successful implant with adequate safety margin.

  6. Development of a current-controlled defibrillator for clinical tests.

    Science.gov (United States)

    Fischer, M; Schönegg, M; Schöchlin, J; Bolz, A

    2002-01-01

    The work presented here is only a part of the development for a new current-controlled defibrillator. In the diploma thesis "Development and construction of a current-controlled defibrillator for clinical tests" the most important part was the control and safety of the defibrillator. To ensure a safe circuit design, a risk-analysis and a Failure Mode and Effects Analysis (FMEA) were necessary. Another major part was the programming of a microcontroller in embedded C and a programmable logic device in Very High Speed Integrated Circuit Description Language (VHDL). The circuit had to be constructed, and the defibrillator was optically decoupled from the laptop for safety reasons. The waveform-data can be transmitted to the microcontroller from the laptop, and the logged data is then transmitted back.

  7. Diet Survey Of Icds Children In Pune City

    Directory of Open Access Journals (Sweden)

    Pratinidhi A.K

    1998-01-01

    Full Text Available Research question: What is the protein & calorie intake of children getting supplementary nutrition under ICDS? Objectives: I To study the protein and calorie intake of children covered under ICDS. ii To study the protein & caloric content of supplementary nutrition. Study design: Cross- sectional. Setting: ICDS project of Pune city. Participants: Children aged 1-6 years, receiving supplementary nutrition from anganwadis. Sample size: 165 children aged 1-<6 tears. Study variables: Knowledge and perception of ICDS, Protein and calorie intake of children, nutritive value of ICDS supplementary foods. Results: There was a gross deficiency of proteins and calories in majority of the children. The protein and calorie intake was less than 50% of recommended daily allowance in 38.2% and 35.7% children respectively. Only 13.9% of children had a protein intake of ³90% of RDA while 12.7% had a calorie consumption of ³90% of RDA. 71.6% of children aged 3-<6 years took the food to their homes and shared with other family members thus depriving them the total benefit of supplementary nutrition. 46.1% mothers perceived the supplementary nutrition to be a substitude. The supplement given at anganwadi had an average nutritive value of 213 calories and 5.1 gm protein as compared to recommended values of 300 calories & 10 gms protein.

  8. Automated external defibrillators: technical considerations and clinical promise.

    Science.gov (United States)

    Takata, T S; Page, R L; Joglar, J A

    2001-12-04

    Early defibrillation is the most important determinant of survival for victims of cardiac arrest due to ventricular fibrillation. The automated external defibrillator (AED) was developed as the result of the American Heart Association's Public Access Defibrillation initiative. The goal of this initiative is to place AEDs in strategic locations so that laypersons with minimal training could promptly defibrillate victims of cardiac arrest. Because of changes in design and the use of alternative waveforms for defibrillation, the modern AED is compact and portable, simple to use, and highly efficacious; in addition, it requires little maintenance. Automated external defibrillators have been used successfully by traditional and nontraditional responders as well as laypersons. In special environments, such as casinos and commercial aircraft, AEDs have performed particularly well. State and federal legislation has eased concerns about AED use by extending legal protection to AED users under Good Samaritan laws. Since the experience continues to be positive, AEDs are being used in increasingly diverse community locations, and public awareness is growing. The American Heart Association's initiative is progressing rapidly.

  9. Nurse- and peer-led self-management programme for patients with an implantable cardioverter defibrillator; a feasibility study

    Directory of Open Access Journals (Sweden)

    van Eijk Jacques

    2007-09-01

    Full Text Available Abstract Background The prevalence of cardiovascular disease is increasing. Improved treatment options increase survival after an acute myocardial infarction or sudden cardiac arrest, although patients often have difficulty adjusting and regaining control in daily life. In particular, patients who received an implantable cardioverter defibrillator (ICD experience physical and psychological problems. Interventions to enhance perceived control and acceptance of the device are therefore necessary. This paper describes a small-scale study to explore the feasibility and the possible benefits of a structured nurse- and peer-led self-management programme ('Chronic Disease Self-Management Program' – CDSMP among ICD patients. Methods Ten male ICD patients (mean age = 65.5 years participated in a group programme, consisting of six sessions, led by a team consisting of a nurse specialist and a patient with cardiovascular disease. Programme feasibility was evaluated among patients and leaders by measuring performance of the intervention according to protocol, attendance and adherence of the participating ICD patients, and patients' and leaders' opinions about the programme. In addition, before and directly after attending the intervention, programme benefits (e.g. perceived control, symptoms of anxiety and depression, and quality of life were assessed. Results The programme was conducted largely according to protocol. Eight patients attended at least four sessions, and adherence ranged from good to very good. On average, the patients reported to have benefited very much from the programme, which they gave an overall report mark of 8.4. The leaders considered the programme feasible as well. Furthermore, improvements were identified for general self-efficacy expectancies, symptoms of anxiety, physical functioning, social functioning, role limitations due to physical problems, and pain. Conclusion This study suggests that a self-management programme led by a

  10. Att leva med implanterad defibrillator : En intervjustudie

    OpenAIRE

    Lindner, Lili; Eliasson, Alexandra

    2012-01-01

                                      The study aimed to explore how patients with ICDs experience their quality of life with a focus on everyday life, electric shocks, and how support from the health service is perceived. The studydesign is descriptive with a qualitative approach. Semi-structured interviews were conducted with seven patients. Data collection lasted for three weeks and interviews were conducted in the participant´s homes, at the participants’ workplaces or over the phone. The st...

  11. Failure of implantable cardioverter-defibrillator leads: a matter of lead size?

    Science.gov (United States)

    Rordorf, Roberto; Poggio, Luca; Savastano, Simone; Vicentini, Alessandro; Petracci, Barbara; Chieffo, Enrico; Klersy, Catherine; Landolina, Maurizio

    2013-02-01

    Small-diameter implantable cardioverter-defibrillator (ICD) Sprint Fidelis and Riata leads have been recalled owing to an increased risk of lead failure, thus arousing the suspicion that lead size might be a critical issue. To compare the incidence of failure of small-diameter (≤8 F) and standard-diameter (>8 F) ICD leads implanted in a single center. From January 2003 to December 2010, 190 Sprint Fidelis, 182 Riata/Riata ST, 99 Optim (Riata Optim/Durata), and 419 standard-diameter leads were implanted in our center. During a median follow-up of 33 months, the overall failure rate was 6.3%. Follow-up duration was similar for Sprint Fidelis, Riata, and standard-diameter leads but shorter for the Optim group. The failure rate was significantly higher in Sprint Fidelis leads than in both standard-diameter (4.8%/year vs 0.8%/year; P<.001) and Riata/Riata ST (4.8%/year vs 2.6%/year; P = .03) leads. The incidence of lead failure in Riata/Riata ST leads proved significantly higher than in standard-diameter leads (2.6%/year vs 0.8%/year; P = .001). No cases of lead failure were recorded in the Optim group. On multivariable analyses, small-diameter (hazard ratio [HR] 5.03, 2.53-10.01, P<.001), Sprint Fidelis (HR 6.3, 3.1-13.3, P<.001), or Riata/Riata ST (HR 4.5, 1.9-10.5, P = .001) leads and age<60 years (HR 2.3, 1.3-4.3, P = .005) were found to independently increase the risk of lead failure. Compared with standard-diameter leads, both Sprint Fidelis and Riata/Riata ST small-diameter ICD leads are at an increased risk of failure, although the incidence of events is significantly lower in the Riata than in the Sprint Fidelis group. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  12. The current state of ICD-10 & preparing for it.

    Science.gov (United States)

    Barbe, David O; Savickis, Mari; Spector, Nancy

    2013-01-01

    The AMA continues to harbor serious concerns and reservations with the significant burden of the ICD-10 mandate and continues to convey these points to policymakers in Washington. The AMA is well aware of the concerns of physicians related to the growing number of burdens being placed on their practices, of which ICD-10 is a large one, and continues to advocate for overall regulatory relief. While the AMA has been working for many years to hold back the implementation of ICD-10, at this time, it does remain a regulatory mandate. Because of this, it is important that physicians prepare for its implementation in order to avoid the rejection of claims and cash flow interruptions.

  13. Body-focused repetitive behavior disorders in ICD-11

    Directory of Open Access Journals (Sweden)

    Jon E. Grant

    2014-01-01

    Full Text Available This article addresses the question of how body-focused repetitive behavior disorders (e.g., trichotillomania and skin-picking disorder should be characterized in ICD-11. The article reviews the historical nosology of the two disorders and the current approaches in DSM-5 and ICD-10. Although data are limited and mixed regarding the optimal relationship between body-focused repetitive behavior disorders and nosological categories, these conditions should be included within the obsessive-compulsive and related disorders category, as this is how most clinicians see these behaviors, and as this may optimize clinical utility. The descriptions of these disorders should largely mirror those in DSM-5, given the evidence from recent field surveys. The recommendations regarding ICD-11 and body-focused repetitive behavior disorders should promote the global identification and treatment of these conditions in primary care settings.

  14. [Functional dysphonia: relation with personality and ICD-10 criteria].

    Science.gov (United States)

    Carvajal, C; Sanfuentes, M T; Eva, P; Jara, C; Lolas Stepke, F

    1992-03-01

    The International Classification of Diseases, 10th. revision (ICD-10) in the category F45 defines the somatoform disorder as a mental disease characterized by the reiterative presentation of somatic symptoms in absence of an organic disease, or the somatic pathology being insufficient to explain the intensity of the symptoms as well as the discomfort and preoccupation of the patient. Fifteen female teachers with functional dysphonia were studied by means of a semistructured interview and psychometric evaluations. Considering dysphonia as the principal symptom, the most frequent diagnosis, in accordance with ICD-10 was "Other somatoform disorder" (F-45.8)(9/15). Five patients were diagnosed as motor dissociative disorder (F-44.4). All the patients had some abnormality of personality (5 with personality disorder and 10 with exacerbation of personality traits). The criteria of ICD-10 to classify the functional dysphonia as Somatoform disorder are discussed. It is suggested that certain personality traits are facilitators for somatization.

  15. Illness perceptions in patients with heart failure and an implantable cardioverter defibrillatorDimensional structure, validity, and correlates of the brief illness perception questionnaire in Dutch, French and German patients

    DEFF Research Database (Denmark)

    Timmermans, I.; Versteeg, H.; Meine, Mathias M

    2017-01-01

    and clinical and psychological correlates of the B-IPQ in Dutch, French and German patients with heart failure and an implantable cardioverter defibrillator (ICD). Method European heart failure patients (n=585) participating in the REMOTE-CIED study completed a set of questionnaires 1–2weeks post ICD.......69, with the ‘Consequences’ subscale being more internally consistent (α=0.80). Both the B-IPQ and its ‘Consequences’ subscale were significantly correlated with a number of psychological characteristics, but not with clinical characteristics. Multivariable logistic regression analysis indicated that threatening illness......-IPQ demonstrated good psychometric properties in Dutch, French and German patients with heart failure. Psychological factors were the most important correlates of patients' perceptions of heart failure, emphasizing the importance of targeting maladaptive illness perceptions in this population, due to their impact...

  16. ICD-10 coding algorithms for defining comorbidities of acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Evans Dewey

    2006-12-01

    Full Text Available Background With the introduction of ICD-10 throughout Canada, it is important to ensure that Acute Myocardial Infarction (AMI comorbidities employed in risk adjustment methods remain valid and robust. Therefore, we developed ICD-10 coding algorithms for nine AMI comorbidities, examined the validity of the ICD-10 and ICD-9 coding algorithms in detection of these comorbidities, and assessed their performance in predicting mortality. The nine comorbidities that we examined were shock, diabetes with complications, congestive heart failure, cancer, cerebrovascular disease, pulmonary edema, acute renal failure, chronic renal failure, and cardiac dysrhythmias. Methods Coders generated a comprehensive list of ICD-10 codes corresponding to each AMI comorbidity. Physicians independently reviewed and determined the clinical relevance of each item on the list. To ensure that the newly developed ICD-10 coding algorithms were valid in recording comorbidities, medical charts were reviewed. After assessing ICD-10 algorithms' validity, both ICD-10 and ICD-9 algorithms were applied to a Canadian provincial hospital discharge database to predict in-hospital, 30-day, and 1-year mortality. Results Compared to chart review data as a 'criterion standard', ICD-9 and ICD-10 data had similar sensitivities (ranging from 7.1 – 100%, and specificities (above 93.6% for each of the nine AMI comorbidities studied. The frequencies for the comorbidities were similar between ICD-9 and ICD-10 coding algorithms for 49,861 AMI patients in a Canadian province during 1994 – 2004. The C-statistics for predicting 30-day and 1 year mortality were the same for ICD-9 (0.82 and for ICD-10 data (0.81. Conclusion The ICD-10 coding algorithms developed in this study to define AMI comorbidities performed similarly as past ICD-9 coding algorithms in detecting conditions and risk-adjustment in our sample. However, the ICD-10 coding algorithms should be further validated in external databases.

  17. The development, evolution, and modifications of ICD-10: challenges to the international comparability of morbidity data.

    Science.gov (United States)

    Jetté, Nathalie; Quan, Hude; Hemmelgarn, Brenda; Drosler, Saskia; Maass, Christina; Moskal, Lori; Paoin, Wansa; Sundararajan, Vijaya; Gao, Song; Jakob, Robert; Ustün, Bedihran; Ghali, William A

    2010-12-01

    The United States is about to make a major nationwide transition from ICD-9-CM coding of hospital discharges to ICD-10-CM, a country-specific modification of the World Health Organization's ICD-10. As this transition occurs, the WHO is already in the midst of developing ICD-11. Given this context, we undertook this review to discuss: (1) the history of the International Classification of Diseases (a core information "building block" for health systems everywhere) from its introduction to the current era of ICD-11 development; (2) differences across country-specific ICD-10 clinical modifications and the challenges that these differences pose to the international comparability of morbidity data; (3) potential strategic approaches to achieving better international ICD-11 comparability. A literature review and stakeholder consultation was carried out. The various ICD-10 clinical modifications (ICD-10-AM [Australia], ICD-10-CA [Canada], ICD-10-GM [Germany], ICD-10-TM [Thailand], ICD-10-CM [United States]) were compared. These ICD-10 modifications differ in their number of codes, chapters, and subcategories. Specific conditions are present in some but not all of the modifications. ICD-11, with a similar structure to ICD-10, will function in an electronic health records environment and also provide disease descriptive characteristics (eg, causal properties, functional impact, and treatment). The threat to the comparability of international clinical morbidity is growing with the development of many country-specific ICD-10 versions. One solution to this threat is to develop a meta-database including all country-specific modifications to ensure more efficient use of people and resources, decrease omissions and errors but most importantly provide a platform for future ICD updates.

  18. Time to choose – DSM-5, ICD-11 or both?

    Directory of Open Access Journals (Sweden)

    Tyrer, Peter

    2014-09-01

    Full Text Available DSM-5 was published in May 2013, and ICD 11 is not due to be published until the end of 2015 at the earliest. Nevertheless, it is possible to make a comparison at this early stage as much of the main decisions have been made with both classifications. DSM-5 aimed to make a paradigm shift by providing objective, independent measures of classification, but in this respect it clearly failed. It did respond to previous criticisms that there were too many diagnoses in the classification and that eliminated some conditions in favour of larger groupings (eg, autism spectrum disorder, but it has still come in for heavy criticism. ICD 11 deviates from DSM-5 in radically different classifications of personality and stress disorders and in general has pursued a different pathway, concentrating on clinical utility as the main guide to the classification. It is up to practitioners to choose which they prefer, but ICD 11 will be in a much stronger position than ICD 10 was when it was published in 1999.

  19. Psychotic disorders in DSM-5 and ICD-11.

    Science.gov (United States)

    Biedermann, Falko; Fleischhacker, W Wolfgang

    2016-08-01

    The Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) was published by the American Psychiatric Association (APA) in 2013, and the Work Group on the Classification of Psychotic disorders (WGPD), installed by the World Health Organization (WHO), is expected to publish the new chapter about schizophrenia and other primary psychotic disorders in 2017. We reviewed the available literature to summarize the major changes, innovations, and developments of both manuals. If available and possible, we outline the theoretical background behind these changes. Due to the fact that the development of ICD-11 has not yet been completed, the details about ICD-11 are still proposals under ongoing revision. In this ongoing process, they may be revised and therefore have to be seen as proposals. DSM-5 has eliminated schizophrenia subtypes and replaced them with a dimensional approach based on symptom assessments. ICD-11 will most likely go in a similar direction, as both manuals are planned to be more harmonized, although some differences will remain in details and the conceptual orientation. Next to these modifications, ICD-11 will provide a transsectional diagnostic criterion for schizoaffective disorders and a reorganization of acute and transient psychotic and delusional disorders. In this manuscript, we will compare the 2 classification systems.

  20. Case study: developing product lines using ICD-9-CM codes.

    Science.gov (United States)

    Benz, P D; Burnham, J

    1985-12-01

    In this marketing case study, Thomas Jefferson University Hospital used a product line approach to maximize the use of its resources. The method used, based on ICD-9-CM codes, fulfilled the demands of increased efficiency by encouraging customer-oriented thinking, enhancing communication with physicians and patients, and helping the institution to compete more effectively.

  1. Prevention of sudden death in hypertrophic cardiomyopathy (HCM):implanted defibrillators in HCM%肥厚型心肌病猝死预防:肥厚型心肌病患者除颤器置入

    Institute of Scientific and Technical Information of China (English)

    Barry J Maron; Paolo Spirito

    2009-01-01

    Hypertrophic cardiomyopathy (HCM) is the most common cause of sudden cardiac death in young people. The implantable cardioverter-defibrillator (ICD), has recently proved to be a safe and effective therapeutic intervention in patients with HCM, both for the primary and secondary prevention of sudden death. Based on recent substantial experience, the ICD intervenes appropriately to termiante ventricular tachycardia/fibrillation (VT/VF), at a rate of 5.5%/year. ICD discharge rate is 4%/year in those patients implanted prophylactically due to one or more major risk markers, but often with considerable delays of up to 10 years before the device is required to intervene appropriately to terminate potentially letal ventricular tachyarrhythmias. Primary prevention of VT/VF occurs with similar frequency in high-risk patients having either 1,2 or ≥ 3 noninvasive risk markers, and about one-third of patients with appropriate device interventions had been implanted for only one risk factor. The ICD has proved reliable in HCM despite the extreme and complex phenotypes often present with massive degrees of left vcntricular hypertrophy, microvascular ischemia, diastolic dysfunction, or dynamic left ventricular outflow tract obstruction. Failure to convert life-threatening ventrieular tachyarrhythmias to normal rhythm is extraordinarily rare. In conclusion, in high-risk HCM patients, ICDs perform in a highly effective fashion,frequently preventing sudden death by aborting primary life-threatening ventricular tachyarrhythmias. A single marker of high risk can be sufficient evidence to justify the recommendation for a prophylactic ICD in selected patients with HCM.

  2. Pacemakers and implantable cardioverter defibrillators - general and anesthetic considerations

    Directory of Open Access Journals (Sweden)

    Amy G. Rapsang

    2014-06-01

    Full Text Available A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia, special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary.

  3. Use a defibrillator, save a life

    CERN Multimedia

    Joannah Caborn Wengler

    2012-01-01

    With the work for Long Shutdown 1 looming on the horizon, the CERN Fire Brigade is anticipating a heavy workload: more people working at CERN means more call-outs. So the more trained first-aiders around to help out before the paramedics arrive, the better. Would you know what to do in a medical emergency?   It could happen at any time: two colleagues are having a coffee at work, when one suddenly clutches his or her chest and falls to the floor unconscious. What would you do? Run to find a first-aider? Call the ambulance and wait, finishing your coffee? Neither response is entirely correct. On Monday 11 June in Building 40 the CMS safety group, in collaboration with the Fire Brigade and the Medical Service, demonstrated the recommended, potentially life-saving response to cardiac arrest (see the video), including the correct use of a defibrillator, ten of which were recently installed in key CERN locations (the Bulletin reported).     “In countries where...

  4. Slow ventricular tachycardia in patients with implantable cardioverter defibrillator%植入植入型心律转复除颤器后慢频率室性心动过速的治疗策略

    Institute of Scientific and Technical Information of China (English)

    孙国建; 何浪; 陈宇宁; 欣明花; 付蕾; 钟诚; 沈法荣

    2016-01-01

    Objective This study aims to assess the incidence of slow ventricular tachycardia ( VT ) and its treatment strategies in implantable cardioverter defibrillator( ICD) patients. Methods All 353 patients with including single and dual-chamber ICD or cardiac resyncronization therapy defibrillator( CRT-D) were en-rolled in this study in Zhejiang Greentown Cardiovascular Hospital from January 2008 to December 2014. Pa-tients had a 3-zone detection configuration: monitoring non treatment(ventricular rate 120 to 180 bpm),anti-tachyarrhythmia pacing(ATP)-low energy shock zone(ventricular rate 180 to 200 bpm),and a ventricular fi-brillation zone.When VT burden was more than 10% and the ventricular rate was less than 160 bpm it needed to optimize the parameters to treat the slow VT. Patients were divided into group A ATP-low energy cardioverter groups(ATP1time-5 J-10 J-maximum energy shock);group B ATP-high energy(ATP 3 times-20 J-the largest energy). Results VT occurred in 102(29%)patients,slow VT occurred in 46(13.1%)patients.Parameters optimization was carried for slow VTs in 27(7. 6%)patients.One time ATP therapy success rate was 67% in group A,ATP+5 J success rate was 79%,ATP+5 J+10 J was 92%. Group B 3 times ATP success rate was 71%,ATP 3 times+20 J was 89%. Conclusion The slow VT had a high incidence in patients with ICD,espe-cially in patients who took up large doses of amiodarone andβreceptor blockers.For patients with heavier bur-den of slow VTs,ATP and small energy electric shock therapy may have greater benefit.%目的:探讨慢频率室性心动过速(室速)在植入植入型心律转复除颤器( ICD)患者中的发生率及治疗策略。方法入选浙江绿城心血管病医院心内科自2008年1月至2014年12月植入的除颤器[单、双腔ICD及心脏再同步治疗除颤器( CRT-D)]患者353例。所有一级预防和二级预防患者按既定不同方案设置参数。术后室速发作负荷≥10%且频率<160次/min定义为需优化参数治

  5. Interest of PET/CT with {sup 18}F-F.D.G. in the diagnosis of endocarditis on pacemaker or defibrillator to be implanted; Interet de la TEP-TDM au 18FDG dans le diagnostic d'endocardite sur pacemaker ou defibrillateur implantable

    Energy Technology Data Exchange (ETDEWEB)

    Bensimhon, L.; Hugonnet, F.; Maunoury, C.; Faraggi, M. [Hopital europeen Georges-Pompidou, Service de medecine nucleaire, 75 - Paris (France); Lavergne, T.; Leheuzey, J.Y. [Hopital europeen Georges-Pompidou, Service de cardiologie, 75 - Paris (France); Mainardi, J.L. [Hopital europeen Georges-Pompidou, Service de microbiologie, 75 - Paris (France); Latremouille, C. [Hopital europeen Georges-Pompidou, Service de chirurgie cardiovasculaire, 75 - Paris (France)

    2010-07-01

    Purpose: Infection of pacemaker device or implantable defibrillators are rare (<5%) but serious and sometimes difficult, we evaluated the interest of PET / CT with {sup 18}F-F.D.G. in the diagnosis. conclusion: PET can be useful to diagnose infection on pacemaker and implantable defibrillators. A prolonged antibiotic therapy may cause false negatives. In our series, the management could have been altered by the examination in 6 out of 21. (N.C.)

  6. Effect of angiotensin-converting enzyme inhibitors and receptor blockers on appropriate implantable cardiac defibrillator shock in patients with severe systolic heart failure (from the GRADE Multicenter Study).

    Science.gov (United States)

    AlJaroudi, Wael A; Refaat, Marwan M; Habib, Robert H; Al-Shaar, Laila; Singh, Madhurmeet; Gutmann, Rebecca; Bloom, Heather L; Dudley, Samuel C; Ellinor, Patrick T; Saba, Samir F; Shalaby, Alaa A; Weiss, Raul; McNamara, Dennis M; Halder, Indrani; London, Barry

    2015-04-01

    Sudden cardiac death (SCD) is a leading cause of mortality in patients with cardiomyopathy. Although angiotensin-converting enzyme inhibitors (ACEi) and angiotensin receptor blockers (ARBs) decrease cardiac mortality in these cohorts, their role in preventing SCD has not been well established. We sought to determine whether the use of ACEi or ARB in patients with cardiomyopathy is associated with a lower incidence of appropriate implantable cardiac defibrillator (ICD) shocks in the Genetic Risk Assessment of Defibrillator Events study that included subjects with an ejection fraction of ≤30% and ICDs. Treatment with ACEi/ARB versus no-ACEi/ARB was physician dependent. There were 1,509 patients (mean age [SD] 63 [12] years, 80% men, mean [SD] EF 21% [6%]) with 1,213 (80%) on ACEi/ARB and 296 (20%) not on ACEi/ARB. We identified 574 propensity-matched patients (287 in each group). After a mean (SD) of 2.5 (1.9) years, there were 334 (22%) appropriate shocks in the entire cohort. The use of ACEi/ARB was associated with lower incidence of shocks at 1, 3, and 5 years in the matched cohort (7.7%, 16.7%, and 18.5% vs 13.2%, 27.5%, and 32.0%; RR = 0.61 [0.43 to 0.86]; p = 0.005). Among patients with glomerular filtration rate (GFR) >60 and 30 to 60 ml/min/1.73 m(2), those on no-ACEi/ARB were at 45% and 77% increased risk of ICD shock compared with those on ACEi/ARB, respectively. ACEi/ARB were associated with significant lower incidence of appropriate ICD shock in patients with cardiomyopathy and GFR ≥30 ml/min/1.73 m(2) and with neutral effect in those with GFR <30 ml/min/1.73 m(2).

  7. Decalogue of electric defibrillation Decálogo de la desfibrilación eléctrica

    Directory of Open Access Journals (Sweden)

    Elkín Ferdinand Cardona Duque

    2001-03-01

    Full Text Available Defibrillation is an emergency procedure and the only effective therapy for ventricular fibrillation. Electrical defibrillation delivers large amounts of current to the myocardium and thus depolarizes it, terminating ventricular fibrillation and other arrhythmias. A defibrillator is a device that administers a controlled electrical shock, allowing the operator to select a variable current at the precise moment, according to patient‘s condition. Understanding defibrillator‘s operation leads to more effective resuscitation rates and more therapeutic alternatives in patients with any cardiac electric disturbance. La desfibrilación es un procedimiento de emergencia y es la única terapia efectiva para el manejo de la fibrilación ventricular. La desfibrilación eléctrica libera corriente en gran cantidad al miocardio, despolarizándolo y terminando la fibrilación ventricular y otras arritmias. Un desfibrilador es un aparato que suministra un choque eléctrico en forma controlada, permitiendo al operador seleccionar una corriente variable en el momento oportuno, de acuerdo con la condición del paciente. El entendimiento del manejo del desfibrilador permite tasas de resucitación más efectivas y más alternativas terapéuticas en pacientes con trastornos del ritmo cardíaco.

  8. [Ethics in intensive care and euthanasia : With respect to inactivating defibrillators at the end of life in terminally ill patients].

    Science.gov (United States)

    Trappe, H-J

    2017-04-01

    In critically ill patients, intensive care medical procedures allow diseases to be cured or controlled that were considered incurable many years ago. For patients with terminal heart failure or heart disease with other severe comorbidities (cancer, stroke), the questions whether the deactivation of defibrillators is appropriate or must be regarded as active euthanasia may arise. Notable cases from the author's hospital are analyzed. The literature on the topic euthanasia and basic literature regarding defibrillator therapy are discussed. It is undisputed that patients as part of their self-determination have the right to renounce treatment. Active euthanasia and the thereby deliberate induction of death is prohibited by law in Germany and will be prosecuted. Passive euthanasia is the omission or reduction of possibly life-prolonging treatment measures. Passive euthanasia requires the patient's consent and is legally and ethically permissible. Indirect euthanasia takes into account acceleration of death as a side effect of a medication. Unpunishable assisted suicide ("assisted suicide") is the mere assistance of self-controlled and self-determined death. Assisted suicide is fundamentally not a criminal offense in Germany. Deactivation of a defibrillator is a treatment discontinuation, which is only permitted in accordance with the wishes of the patient. It is not a question of passive or active euthanasia. Involvement of a local ethics committee and/or legal consultation is certainly useful and sometimes also allows previously unrecognized questions to be answered.

  9. 77 FR 8877 - ICD-9-CM Coordination and Maintenance (C&M) Committee Meeting

    Science.gov (United States)

    2012-02-15

    ... HUMAN SERVICES Centers for Disease Control and Prevention ICD-9-CM Coordination and Maintenance (C&M... Standards Staff, announces the following meeting. Name: ICD-9-CM Coordination and Maintenance (C&M... ), for questions about the registration process. Purpose: The ICD-9-CM Coordination and...

  10. Marketing defibrillation training programs and bystander intervention support.

    Science.gov (United States)

    Sneath, Julie Z; Lacey, Russell

    2009-01-01

    This exploratory study identifies perceptions of and participation in resuscitation training programs, and bystanders' willingness to resuscitate cardiac arrest victims. While most of the study's participants greatly appreciate the importance of saving someone's life, many indicated that they did not feel comfortable assuming this role. The findings also demonstrate there is a relationship between type of victim and bystanders' willingness to intervene. Yet, bystander intervention discomfort can be overcome with cardiopulmonary resuscitation and defibrillation training, particularly when the victim is a coworker or stranger. Further implications of these findings are discussed and modifications to public access defibrillation (PAD) training programs' strategy and communications are proposed.

  11. A Clinical Review of Implantable Cardioverter Defibrillators and Bi-Ventricular Pacemakers at one Institute

    Directory of Open Access Journals (Sweden)

    Ahmad Nasir

    2010-01-01

    Full Text Available Background: ICD/BVP indications are expanding. They areexpensive devices and historically, morbidities associated withtheir use were high. The starting experience at the Gold CoastHospital is being reviewed.Methods: A retrospective chart review of all the ICD/BVPsimplanted in the Gold Coast Hospital from 06/07/2007 –17/06/2008, with special emphasis on device indications andcomplications.Results: Devices implanted were (31. Primary preventiondevices (67%, secondary prevention devices (33%.Indications were; Non-ischemic Dilated Cardiomyopathy(35%, Out-of-hospital Cardiac Arrest (26%, Conscious VT(13%, Ischemic Dilated Cardiomyopathy (10%, In-hospitalCardiac Arrest (6%, Long-QT Syndrome (6% andCatecholamine-related Polymorphic VT (3%. Majorcomplications reported; lung contusion (1, left haemothorax(1, failed coronary sinus lead positioning (2, lead repositioning(2, atrial lead removal (1, left subclavian veinthrombosis (1, lead malfunction leading to VT under sensingand syncope (1. Device-administered therapies were eight;Inappropriate discharges (5, Appropriate discharges (1,successful Anti-tachycardia Pacing (2.Conclusions: We believe that ICDs are very effective lifesavingdevices but unfortunately they still are very expensiveand their use can be associated with significant morbiditiesespecially during the learning curve.

  12. Prediction of Appropriate Shocks Using 24-Hour Holter Variables and T-Wave Alternans After First Implantable Cardioverter-Defibrillator Implantation in Patients With Ischemic or Nonischemic Cardiomyopathy.

    Science.gov (United States)

    Seegers, Joachim; Bergau, Leonard; Expósito, Pascal Muñoz; Bauer, Axel; Fischer, Thomas H; Lüthje, Lars; Hasenfuß, Gerd; Friede, Tim; Zabel, Markus

    2016-07-01

    In patients treated with implantable cardioverter defibrillator (ICD), prediction of both overall survival and occurrence of shocks is important if improved patient selection is desired. We prospectively studied the predictive value of biomarkers and indexes of cardiac and renal function and spectral microvolt T-wave alternans testing and 24-hour Holter variables in a population who underwent first ICD implantation. Consecutive patients in sinus rhythm with ischemic or dilated cardiomyopathy scheduled for primary or secondary prophylactic ICD implantation were enrolled. Exercise microvolt T-wave alternans and 24-hour Holter for number of ventricular premature contractions (VPCs), deceleration capacity, heart rate variability, and heart rate turbulence were done. Death of any cause and first appropriate ICD shock were defined as end points. Over 33 ± 15 months of follow-up, 36 of 253 patients (14%) received appropriate shocks and 39 of 253 patients (15%) died. Only 3 of 253 patients (1%) died after receiving at least 1 appropriate shock. In univariate analyses, New York Heart Association class, ejection fraction, N-terminal pro brain-type natriuretic peptide (NT-proBNP), renal function, ICD indication, deceleration capacity, heart rate variability, and heart rate turbulence were predictive of all-cause mortality and VPC number and deceleration capacity predicted first appropriate shock. NT-proBNP (≥1,600 pg/ml) was identified as the only independent predictor of all-cause mortality (hazard ratio 3.0, confidence interval 1.3 to 7.3, p = 0.014). In contrast, VPC number predicted appropriate shocks (hazard ratio 2.3, confidence interval 1.0 to 5.5, p = 0.047) as the only independent risk marker. In conclusion, NT-proBNP is a strong independent predictor of mortality in a typical prospective cohort of newly implanted patients with ICD, among many electrocardiographic and clinical variables studied. Number of VPCs was identified as a predictor of appropriate shocks

  13. Alternative models of disorders of traumatic stress based on the new ICD-11 proposals.

    Science.gov (United States)

    Shevlin, M; Hyland, P; Karatzias, T; Fyvie, C; Roberts, N; Bisson, J I; Brewin, C R; Cloitre, M

    2017-05-01

    Although there is emerging evidence for the factorial validity of the distinction between post-traumatic stress disorder (PTSD) and complex PTSD (CPTSD) proposed in ICD-11, such evidence has been predominantly based on using selected items from individual scales that describe these factors. We have attempted to address this gap in the literature by testing a range of alternative models of disorders of traumatic stress using a broader range of symptoms and standardized measures. Participants in this cross-sectional study were a sample of individuals who were referred for psychological therapy to a National Health Service (NHS) trauma centre in Scotland (N = 195). Participants were recruited over a period of 18 months and completed measures of stressful life events, DSM-5 PTSD, emotion dysregulation, self-esteem and interpersonal difficulties. Overall, results indicate that a structural model incorporating six first-order factors (re-experiencing, avoidance of traumatic reminders, sense of threat, affective dysregulation, negative self-concept and disturbances in relationships) and two second-order factors (PTSD and disturbances in self-organization [DSO]) was the best fitting. The model presented with good concurrent validity. Childhood trauma was found to be more strongly associated with DSO than with PTSD. Our results are in support of the ICD-11 proposals for PTSD and CPTSD. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Preliminary studies of the ICD-11 classification of personality disorder in practice.

    Science.gov (United States)

    Tyrer, Peter; Crawford, Mike; Sanatinia, Rahil; Tyrer, Helen; Cooper, Sylvia; Muller-Pollard, Chris; Christodoulou, Polyxeni; Zauter-Tutt, Maria; Miloseska-Reid, Katerina; Loebenberg, Gemma; Guo, Boliang; Yang, Min; Wang, Duolao; Weich, Scott

    2014-10-01

    This study aims to compare ICD-10 and putative ICD-11 classifications of personality disorder in different clinical populations. Prospective recording of ICD-10 and ICD-11 personality disorder classifications was carried out in (1) an anxious medical population, (2) an acute psychiatric in-patient population and (3) a retrospective recording of a mixed anxiety depression cohort in which all baseline data were scored from baseline information using the ICD-11 classification and compared with the original ICD-10 assessments. Comparison of ICD-10 and ICD-11 prevalence of personality disorder in each population was carried out. Data from 722 patients were recorded. Using the ICD-10 criteria, the prevalence of generic personality disorder was 33.8% compared with 40.4% using the ICD-11 ones (χ2  = 6.7; P personality difficulty. Severity level varied greatly by population; severe personality disorder was five times more common in the inpatient group. The four domain traits originally denoted as qualifying severity in ICD-11, negative affective, dissocial, anankastic and detached, were linked to anxious, borderline, dissocial, anankastic and schizoid personality disorders in ICD-10. Many patients had pathology in two or more domains. The ICD-11 classification of personality disorder yields somewhat higher levels of personality dysfunction than ICD-10, possibly because the age range for the onset of diagnosis is now flexible. The range of severity levels make the classification more useful than ICD-10 in clinical practice as it identifies the greater pathology necessary for intervention. Copyright © 2014 John Wiley & Sons, Ltd.

  15. [Automatic external defibrillator--mode of operation and clinical use].

    Science.gov (United States)

    Wieneke, H; Konorza, T; Breuckmann, F; Reinsch, N; Erbel, R

    2008-10-01

    Every year about 100,000 persons die from sudden cardiac death (SCD) in Germany. Although many efforts have been undertaken, mortality remains high. Only 2 - 10% of patients with out-off hospital SCD can finally be discharged from hospital after resuscitation. Observational studies show that ventricular fibrillation and ventricular tachycardia are the primary arrhythmias underlying SCD. For both arrhythmias the main determinant for survival is the time between onset and termination by defibrillation. The chance of survival declines by 10% for every minute of delay. These findings prompted the concept of early defibrillation by first responders. Many studies have shown that non-medical professionals, like police men, firemen or security officers, often arrive at the patient more early than emergency medical service. Thus, "smart" automated external defibrillators (AEDs), designed to identify VT/VF and prompt the user when to deliver a shock were introduced. These devices allow lay rescuers to terminate ventricular arrhythmias before the arrival of medical professionals. By this approach the time to defibrillation could be reduced and a significant reduction in mortality could be documented in selected situation. These encouraging results initialled the installation of AED at public places like aircrafts, airports, underground stations and shopping males. Due to the success of this approach doctors are more and more confronted with questions about technical details, reliability and cost effectiveness of these devices. The present review should give an overview about the current studies and guidelines.

  16. Advantage of four-electrode over two-electrode defibrillators

    Science.gov (United States)

    Bragard, J.; Šimić, A.; Laroze, D.; Elorza, J.

    2015-12-01

    Defibrillation is the standard clinical treatment used to stop ventricular fibrillation. An electrical device delivers a controlled amount of electrical energy via a pair of electrodes in order to reestablish a normal heart rate. We propose a technique that is a combination of biphasic shocks applied with a four-electrode system rather than the standard two-electrode system. We use a numerical model of a one-dimensional ring of cardiac tissue in order to test and evaluate the benefit of this technique. We compare three different shock protocols, namely a monophasic and two types of biphasic shocks. The results obtained by using a four-electrode system are compared quantitatively with those obtained with the standard two-electrode system. We find that a huge reduction in defibrillation threshold is achieved with the four-electrode system. For the most efficient protocol (asymmetric biphasic), we obtain a reduction in excess of 80% in the energy required for a defibrillation success rate of 90%. The mechanisms of successful defibrillation are also analyzed. This reveals that the advantage of asymmetric biphasic shocks with four electrodes lies in the duration of the cathodal and anodal phase of the shock.

  17. 21 CFR 870.5310 - Automated external defibrillator.

    Science.gov (United States)

    2010-04-01

    ... device with a rhythm recognition detection system that delivers into a 50 ohm test load an electrical shock of a maximum of 360 joules of energy used for defibrillating (restoring normal heart rhythm) the atria or ventricles of the heart. An AED analyzes the patient's electrocardiogram, interprets...

  18. [Full dental rehabilitation of a patient with implantable cardioverter defibrillator].

    Science.gov (United States)

    Imre, Ildikó; Tóth, Zsuzsanna

    2012-06-01

    During dental rehabilitation of a patient with ICD, an upper telescope retained overdenture with acrylic baseplate and lower cantilever bridges were constructed. In the consultation following the anamnesis and the clinical examination, the cardiologist did not believe antibiotic profilaxis to be necessary, adding that it is advisable to avoid the use of ultrasonic depurator and electrocauter. Nowadays after saving the life the improving of patient's better quality of life is an important aspect. The risk of ICD-implantation is minimal however, not negligible, the patient can pursue a way of life free of limitation. According to the latest trends, the number of ICD-implantations will increase exponentially in the near future, due to the aging of the population, the simplification and safeness of implantation and the increase of patients who can be treated with the device. In case of arritmia or putative dysfunction, the latest ICD-s are able to send emergency alert to the arritmia centre with the help of an outer transmitter. Probably the system will completely change the follow-up of patients with ICD within the next few years, clinical researches of its efficiency are going on at present.

  19. Greater Prevalence of Proposed ICD-11 Alcohol and Cannabis Dependence Compared to ICD-10, DSM-IV, and DSM-5 in Treated Adolescents.

    Science.gov (United States)

    Chung, Tammy; Cornelius, Jack; Clark, Duncan; Martin, Christopher

    2017-09-01

    Proposed International Classification of Diseases, 11th edition (ICD-11), criteria for substance use disorder (SUD) radically simplify the algorithm used to diagnose substance dependence. Major differences in case identification across DSM and ICD impact determinations of treatment need and conceptualizations of substance dependence. This study compared the draft algorithm for ICD-11 SUD against DSM-IV, DSM-5, and ICD-10, for alcohol and cannabis. Adolescents (n = 339, ages 14 to 18) admitted to intensive outpatient addictions treatment completed, as part of a research study, a Structured Clinical Interview for DSM SUDs adapted for use with adolescents and which has been used to assess DSM and ICD SUD diagnoses. Analyses examined prevalence across classification systems, diagnostic concordance, and sources of diagnostic disagreement. Prevalence of any past-year proposed ICD-11 alcohol or cannabis use disorder was significantly lower compared to DSM-IV and DSM-5 (ps DSM-5, and ICD-10 (ps DSM-5 SUD diagnoses showed only moderate concordance. For both alcohol and cannabis, youth typically met criteria for an ICD-11 dependence diagnosis by reporting tolerance and much time spent using or recovering from the substance, rather than symptoms indicating impaired control over use. The proposed ICD-11 dependence algorithm appears to "overdiagnose" dependence on alcohol and cannabis relative to DSM-IV and ICD-10 dependence, and DSM-5 moderate/severe use disorder, generating potential "false-positive" cases of dependence. Among youth who met criteria for proposed ICD-11 dependence, few reported impaired control over substance use, highlighting ongoing issues in the conceptualization and diagnosis of SUD. Copyright © 2017 by the Research Society on Alcoholism.

  20. A Self-Report Measure for the ICD-11 Dimensional Trait Model Proposal: The Personality Inventory for ICD-11.

    Science.gov (United States)

    Oltmanns, Joshua R; Widiger, Thomas A

    2017-02-23

    Proposed for the 11th edition of the World Health Organization's International Classification of Diseases (ICD-11) is a dimensional trait model for the classification of personality disorder (Tyrer, Reed, & Crawford, 2015). The ICD-11 proposal consists of 5 broad domains: negative affective, detachment, dissocial, disinhibition, and anankastic (Mulder, Horwood, Tyrer, Carter, & Joyce, 2016). Several field trials have examined this proposal, yet none has included a direct measure of the trait model. The purpose of the current study was to develop and provide initial validation for the Personality Inventory for ICD-11 (PiCD), a self-report measure of this proposed 5-domain maladaptive trait model. Item selection and scale construction proceeded through 3 initial data collections assessing potential item performance. Two subsequent studies were conducted for scale validation. In Study 1, the PiCD was evaluated in a sample of 259 MTurk participants (who were or had been receiving mental health treatment) with respect to 2 measures of general personality structure: The Eysenck Personality Questionnaire-Revised and the 5-Dimensional Personality Test. In Study 2, the PiCD was evaluated in an additional sample of 285 participants with respect to 2 measures of maladaptive personality traits: The Personality Inventory for DSM-5 and the Computerized Adaptive Test for Personality Disorders. Study 3 provides an item-level exploratory structural equation model with the combined samples from Studies 1 and 2. The results are discussed with respect to the validity of the measure and the potential benefits for future research in having a direct, self-report measure of the ICD-11 trait proposal. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  1. Electrical storm: Incidence, Prognosis and Therapy

    Science.gov (United States)

    Proietti, Riccardo; Sagone, Antonio

    2011-01-01

    Implantable defibrillators are lifesavers and have improved mortality rates in patients at risk of sudden death, both in primary and secondary prevention. However, they are unable to modify the myocardial substrate, which remains susceptible to life-threatening ventricular arrhythmias. Electrical storm is a clinical entity characterized the recurrence of hemodynamically unstable ventricular tachycardia and/or ventricular fibrillation, twice or more in 24 hours, requiring electrical cardioversion or defibrillation. With the arrival of the implantable cardioverter-defibrillator, this definition was broadened, and electrical storm is now defined as the occurrence of three or more distinct episodes of ventricular tachycardia or ventricular fibrillation in 24 hours, requiring the intervention of the defibrillator (anti-tachycardia pacing or shock). Clinical presentation can be very dramatic, with multiple defibrillator shocks and hemodynamic instability. Managing its acute presentation is a challenge, and mortality is high both in the acute phase and in the long term. In large clinical trials involving patients implanted with a defibrillator both for primary and secondary prevention, electrical storm appears to be a harbinger of cardiac death, with notably high mortality soon after the event. In most cases, the storm can be interrupted by medical therapy, though transcatheter radiofrequency ablation of ventricular arrhythmias may be an effective treatment for refractory cases. This narrative literature review outlines the main clinical characteristics of electrical storm and emphasises critical points in approaching and managing this peculiar clinical entity. Finally focus is given to studies that consider transcatheter ablation therapy in cases refractory to medical treatment. PMID:21468247

  2. Longitudinal changes in quality of life following ICD implant and the impact of age, gender, and ICD shocks: observations from the INTRINSIC RV trial.

    Science.gov (United States)

    Gopinathannair, Rakesh; Lerew, Darin R; Cross, Natalie J; Sears, Samuel F; Brown, Scott; Olshansky, Brian

    2017-04-01

    ICDs can improve survival in at-risk patients but no consensus exists with respect to their impact on health-related quality of life (QOL). Moreover, the data are unclear on QOL benefits in specific patient subgroups. We sought to analyze, in the INTRINSIC RV ICD trial population, health-related QOL longitudinally following ICD implant and consider impact of age, gender, and ICD shocks on QOL by employing a global measure of health-related QOL. One thousand five hundred thirty patients had an ICD implanted. One week after implant (n = 1461), 988 patients were randomized to DDDR with AV search hysteresis (n = 502) or VVI (n = 486) programming. QOL data, using the SF-36 short form, were obtained for the 1461 patient cohort, irrespective of randomization status, at baseline and prospectively for 1 year following ICD implant. Longitudinal mixed-effect analyses revealed significant improvements from baseline across all SF-36 subscales and component scores for the overall study cohort. Women had a substantially lower QOL at baseline, although their improvement after implant was similar to men. Patients implant and suggest that benefits associated with ICD implantation go beyond the direct treatment of arrhythmias, with benefits seen across genders and different age groups. These results further highlight that ICD implantation, in and of itself, does not reduce QOL.

  3. Impulse control disorders and related behaviours (ICD-RBs in Parkinson′s disease patients: Assessment using “Questionnaire for impulsive-compulsive disorders in Parkinson′s disease” (QUIP

    Directory of Open Access Journals (Sweden)

    Ashish Sharma

    2015-01-01

    Full Text Available Background: There is limited data on the prevalence of impulse control disorder and related behaviors (ICD-RBs in Indian patients with Parkinson′s Disease (PD. In the context of potential genetic and environmental factors affecting the expression of ICD-RBs, studying other multiethnic populations may bring in-sights into the mechanisms of these disorders. Objectives: To ascertain point prevalence estimate of ICD-RBs in Indian PD patients, using the validated “Questionnaire for Impulsive-Compulsive Disorders in Parkinson′s disease (QUIP” and to examine their association with Dopamine replacement therapy (DRT. Materials and Methods: This was a hospital based observational cross-sectional study. After taking informed consent, patients and their informants (spouse, or primary caregiver were made to complete the QUIP, and were instructed to answer questions based on behaviors that occurred anytime during PD that lasted at least four consecutive weeks. Results: Total of 299 patients participated in the study. At least one ICD-RB was present in 128 (42.8%, at least one Impulse control disorder (ICD was present in 74 (24.75% and at least one Impulse control related compulsive behaviour (ICRB was present in 93 (31.1% patients. Punding was the most frequent (12.4% followed by hyper sexuality (11.04%, compulsive hobbyism (9.4%, compulsive shopping (8.4%, compulsive medication use (7.7%, compulsive eating (5.35%, walkabout (4% and pathological gambling (3.3%. ≥ 2 ICD-RBs were observed in 15.7% of patients. After multivariate analysis, younger age of onset, being unmarried were specifically associated with presence of ICD. Longer disease duration was specifically associated with presence of ICRB. Whereas smoking and higher dopamine levodopa equivalent daily doses (DA LEDD were associated with both presence of ICD and ICRB. Higher LD LEDD was specifically associated with presence of ICD-RB. Conclusions: Our study revealed a relatively higher

  4. Preliminary Development of an Informational Media Use Measure for Patients with Implanted Defibrillators: Toward a Model of Social-Ecological Assessment of Patient Education and Support.

    Science.gov (United States)

    Knoepke, Christopher E; Matlock, Daniel D

    2017-05-31

    Social work interventions in health care, particularly those that involve working with people being treated for chronic and life-threatening conditions, frequently involve efforts to educate patients about their disease, treatment options, safety planning, medical adherence, and other associated issues. Despite an intuitive notion that patients access information about all of these issues through a variety of media-both inside and outside the clinical encounter, created by professionals and by others-there currently exists no validated means of assessing patients' use of these forms of information. To address this gap, authors first created candidate item measures with input from both physicians and a small group of diverse patients who currently have an implantable cardioverter defibrillator (ICD), a sophisticated cardiac device for which a trajectory model of social work intervention was recently outlined. Authors then surveyed a group of 205 individuals who have these devices, assessing their use of various media to learn about ICDs. They then conducted factor and item analysis to refine and remove poorly performing items while delineating forms of media use by type. The resultant preliminary measure of informational media use can be further refined and adapted for use with any clinical population. © 2017 National Association of Social Workers.

  5. [Automatic, implantible cardioverter-defibrillator in a patient with chronic Chagas cardiopathy and sustained ventricular tachycardia].

    Science.gov (United States)

    Rodríguez, H; Muñoz, M; Llamas, G; Iturralde, P; Medeiros, A; Delgado, L; Mar, R; Rucinque, F; Bayram, E

    1998-01-01

    We studied a 48 years old woman, with chronic Chagasic cardiopathy, manifested with cardiomegaly, heart failure and syncope, due to a sustained ventricular tachycardia (SVT) of two different configurations (left bundle branch block and right bundle branch block). During electrophysiological testing, both types of ventricular tachycardia were reproduced. Successful ablation therapy of the right branch of His was performed due to suspicion of the bundle branch reentrant tachycardia, with a left bundle branch block. The patient continued to show SVT episodes, now with right bundle branch block pattern. Cardioverter Defibrillator was implanted. We report this case due to the rare frequency of Chagas' disease, where it could be a cause of heart disease, since the existence of the parasite (trypanosoma cruzi) and its vector (Triatoma) has been identified in some rural and suburban zones in the state of Aguascalientes, Mexico.

  6. ICD-11 for quality and safety: overview of the WHO Quality and Safety Topic Advisory Group.

    Science.gov (United States)

    Ghali, William A; Pincus, Harold A; Southern, Danielle A; Brien, Susan E; Romano, Patrick S; Burnand, Bernard; Drösler, Saskia E; Sundararajan, Vijaya; Moskal, Lori; Forster, Alan J; Gurevich, Yana; Quan, Hude; Colin, Cyrille; Munier, William B; Harrison, James; Spaeth-Rublee, Brigitta; Kostanjsek, Nenad; Ustün, T Bedirhan

    2013-12-01

    This paper outlines the approach that the WHO's Family of International Classifications (WHO-FIC) network is undertaking to create ICD-11. We also outline the more focused work of the Quality and Safety Topic Advisory Group, whose activities include the following: (i) cataloguing existing ICD-9 and ICD-10 quality and safety indicators; (ii) reviewing ICD morbidity coding rules for main condition, diagnosis timing, numbers of diagnosis fields and diagnosis clustering; (iii) substantial restructuring of the health-care related injury concepts coded in the ICD-10 chapters 19/20, (iv) mapping of ICD-11 quality and safety concepts to the information model of the WHO's International Classification for Patient Safety and the AHRQ Common Formats; (v) the review of vertical chapter content in all chapters of the ICD-11 beta version and (vi) downstream field testing of ICD-11 prior to its official 2015 release. The transition from ICD-10 to ICD-11 promises to produce an enhanced classification that will have better potential to capture important concepts relevant to measuring health system safety and quality-an important use case for the classification.

  7. Bystander Defibrillation for Out-of-Hospital Cardiac Arrest in Public vs Residential Locations

    DEFF Research Database (Denmark)

    Hansen, Steen Møller; Hansen, Carolina Malta; Folke, Fredrik

    2017-01-01

    Importance: Bystander-delivered defibrillation (hereinafter referred to as bystander defibrillation) of patients with out-of-hospital cardiac arrests (OHCAs) remains limited despite the widespread dissemination of automated external defibrillators (AEDs). Objective: To examine calendar changes...... in bystander defibrillation and subsequent survival according to a public or a residential location of the cardiac arrest after nationwide initiatives in Denmark to facilitate bystander-mediated resuscitative efforts, including bystander defibrillation. Design, Setting, and Participants: This nationwide study......, 2016. Exposures: Nationwide initiatives to facilitate bystander resuscitative efforts, including bystander defibrillation, consisted of resuscitation training of Danish citizens, dissemination of on-site AEDs, foundation of an AED registry linked to emergency medical dispatch centers, and dispatcher...

  8. Custo-efetividade de cardiodesfibriladores implantáveis no Brasil nos setores público e privado Cost-effectiveness of implantable cardioverter defibrillators in Brazil in the public and private sectors

    Directory of Open Access Journals (Sweden)

    Rodrigo Antonini Ribeiro

    2010-10-01

    Full Text Available FUNDAMENTO: Vários ensaios clínicos randomizados demonstraram a efetividade do cardiodesfibrilador implantável (CDI na redução de morte de pacientes com insuficiência cardíaca congestiva (ICC. Estudos de países desenvolvidos já avaliaram a custo-efetividade do CDI, porém as informações não são transferíveis para o Brasil. OBJETIVO: Avaliar a custo-efetividade do CDI em pacientes com ICC sob duas perspectivas: pública e saúde suplementar. MÉTODOS: Um modelo de Markov foi criado para analisar a relação de custo-efetividade incremental (RCEI do CDI, comparado à terapia convencional, em pacientes com ICC. Efetividade foi medida em anos de vida ajustados para qualidade (QALY. Na literatura, buscaram-se dados de efetividade e complicações. Custos foram extraídos das tabelas do SUS e de valores praticados pelos convênios, assim como médias de internações hospitalares. Análises de sensibilidade univariadas foram feitas em todas as variáveis do modelo. RESULTADOS: A RCEI foi de R$ 68.318/QALY no cenário público e R$ 90.942/QALY no privado. Esses valores são superiores aos sugeridos como pontos de corte pela Organização Mundial da Saúde, de três vezes o PIB per capita (R$ 40.545 no Brasil. Variáveis mais influentes na análise de sensibilidade foram: custo do CDI, intervalo de troca do gerador e efetividade do CDI. Em simulação de cenário semelhante ao MADIT-I, as relações foram de R$ 23.739/QALY no cenário público e R$ 33.592/QALY no privado. CONCLUSÃO: Para a população em geral com ICC, a relação de RCEI do CDI, tanto na perspectiva pública como na privada, é elevada. Resultados mais favoráveis ocorrem em pacientes com alto risco de morte súbita.BACKGROUND: Many randomized clinical trials have demonstrated the effectiveness of the implantable cardioverter-defibrillator (ICDs in death reduction of chronic heart failure (CHF patients. Some developed countries studies have evaluated its cost

  9. ICD-10: are you ready for a brave new world?

    Science.gov (United States)

    Cannon, Barbara A; Strubler, Diana L

    2014-09-01

    The ICD-10 transition will be an evolutionary process. Relying on the EHR or certified coding staff alone will not be sufficient. The EHR can facilitate easy search tools that assist the provider in selecting a diagnosis. Billing staff are an invaluable resource to help validate that coding and documentation are in sync but the burden will clearly rest on the provider. The provider will be juggling a new code structure, drilling down to new levels of complexity and ensuring their documentation supports the specificity of the new codes selected, all while managing a full patient schedule. Education for the provider will be of paramount importance as they navigate this brave new world.

  10. Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

    Energy Technology Data Exchange (ETDEWEB)

    Ghafarian, Pardis [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Aghamiri, S.M.R. [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Ay, Mohammad R. [Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Research Institute for Nuclear Medicine, Tehran (Iran, Islamic Republic of); Rahmim, Arman [Johns Hopkins University, Department of Radiology, Baltimore, MD (United States); Schindler, Thomas H. [Geneva University, Cardiovascular Center, Nuclear Cardiology, Geneva (Switzerland); Ratib, Osman [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland)

    2011-02-15

    Cardiac PET/CT imaging is often performed in patients with pacemakers and implantable cardioverter defibrillator (ICD) leads. However, metallic implants usually produce artefacts on CT images which might propagate to CT-based attenuation-corrected (CTAC) PET images. The impact of metal artefact reduction (MAR) for CTAC of cardiac PET/CT images in the presence of pacemaker, ICD and ECG leads was investigated using both qualitative and quantitative analysis in phantom and clinical studies. The study included 14 patients with various leads undergoing perfusion and viability examinations using dedicated cardiac PET/CT protocols. The PET data were corrected for attenuation using both artefactual CT images and CT images corrected using the MAR algorithm. The severity and magnitude of metallic artefacts arising from these leads were assessed on both linear attenuation coefficient maps ({mu}-maps) and attenuation-corrected PET images. CT and PET emission data were obtained using an anthropomorphic thorax phantom and a dedicated heart phantom made in-house incorporating pacemaker and ICD leads attached at the right ventricle of the heart. Volume of interest-based analysis and regression plots were performed for regions related to the lead locations. Bull's eye view analysis was also performed on PET images corrected for attenuation with and without the MAR algorithm. In clinical studies, the visual assessment of PET images by experienced physicians and quantitative analysis did not reveal erroneous interpretation of the tracer distribution or significant differences when PET images were corrected for attenuation with and without MAR. In phantom studies, the mean differences between tracer uptake obtained without and with MAR were 10.16{+-}2.1% and 6.86{+-}2.1% in the segments of the heart in the vicinity of metallic ICD or pacemaker leads, and were 4.43{+-}0.5% and 2.98{+-}0.5% in segments far from the leads. Although the MAR algorithm was able to effectively improve

  11. Risk of pacemaker or implantable cardioverter defibrillator after radiotherapy for early-stage breast cancer in Denmark, 1982-2005.

    Science.gov (United States)

    Rehammar, Jens Christian; Johansen, Jens Brock; Jensen, Maj-Britt; Videbæk, Lars; Jørgensen, Ole Dan; Lorenzen, Ebbe; Ewertz, Marianne

    2017-01-01

    To examine the risk of cardiac conduction abnormalities or severe ventricular arrhythmias requiring implantation of a cardiac implantable electronic device (CIED), either a pacemaker or an implantable cardioverter-defibrillator, subsequent to breast cancer (BC) radiotherapy (RT). All women treated for early-stage BC in Denmark from 1982 to 2005 were identified from the Danish Breast Cancer Cooperative Group. By record linkage to the Danish Pacemaker and ICD Registry information was retrieved on CIED implants subsequent to RT. Standardized incidence ratios (SIR) of CIED implantation were estimated for women receiving RT and compared to women not receiving RT for BC. Uni- and multivariate Poisson regression models were used to estimate incidence rate ratios (IRR) among irradiated women compared to non-irradiated. Of 44,423 BC patients, 179 had a CIED implanted among 18,251 women who received RT, and 401 had a CIED in 26,172 who did not receive RT. The unadjusted IRR was 1.09 (0.91-1.30 95% CI) for CIED implants among women receiving RT compared to non-irradiated women and the IRR was 1.13 (0.93-1.38 95% CI) when adjustments were made. BC RT as practiced in Denmark in 1982-2005 did not increase the risk of CIED implants. This indicates that RT for BC does not increase the risk of severe ventricular arrhythmias or cardiac conduction abnormalities. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Is modification of the VVI backup mode in implantable cardioverter-defibrillators from St Jude medical required due to increased risk of inappropriate shocks?

    DEFF Research Database (Denmark)

    Philbert, Berit T; Tfelt-Hansen, Jacob; Jacobsen, Peter K

    2017-01-01

    a ventricular fibrillation (VF) zone starting at 146 b.p.m., with shock therapy only and changes in sensitivity settings making the ICD more sensitive. In all cases, the reason for the multiple inappropriate shocks was that the VF zone was reached due to exercise-induced sinus tachycardia or due to oversensing...

  13. Cardiac sympathetic innervation assessed with (123)I-MIBG retains prognostic utility in diabetic patients with severe left ventricular dysfunction evaluated for primary prevention implantable cardioverter-defibrillator.

    Science.gov (United States)

    García-González, P; Fabregat-Andrés, Ó; Cozar-Santiago, P; Sánchez-Jurado, R; Estornell-Erill, J; Valle-Muñoz, A; Quesada-Dorador, A; Payá-Serrano, R; Ferrer-Rebolleda, J; Ridocci-Soriano, F

    2016-01-01

    Scintigraphy with iodine-123-metaiodobenzylguanidine ((123)I-MIBG) is a non-invasive tool for the assessment of cardiac sympathetic innervation (CSI) that has proven to be an independent predictor of survival. Recent studies have shown that diabetic patients with heart failure (HF) have a higher deterioration in CSI. It is unknown if (123)I-MIBG has the same predictive value for diabetic and non-diabetic patients with advanced HF. An analysis is performed to determine whether CSI with (123)I-MIBG retains prognostic utility in diabetic patients with HF, evaluated for a primary prevention implantable cardioverter-defibrillator (ICD). Seventy-eight consecutive HF patients (48 diabetic) evaluated for primary prevention ICD implantation were prospectively enrolled and underwent (123)I-MIBG to assess CSI (heart-to-mediastinum ratio - HMR). A Cox proportional hazards multivariate analysis was used to determine the influence of (123)I-MIBG images for prediction of cardiac events in both diabetic and non-diabetic patients. The primary end-point was a composite of arrhythmic event, cardiac death, or admission due to HF. During a mean follow-up of 19.5 [9.3-29.3] months, the primary end-point occurred in 24 (31%) patients. Late HMR was significantly lower in diabetic patients (1.30 vs. 1.41, p=0.014). Late HMR≤1.30 was an independent predictor of cardiac events in diabetic (hazard ratio 4.53; p=0.012) and non-diabetic patients (hazard ratio 12.31; p=0.023). Diabetic patients with HF evaluated for primary prevention ICD show a higher deterioration in CSI than non-diabetics; nevertheless (123)I-MIBG imaging retained prognostic utility for both diabetic and non-diabetic patients. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  14. International Database events common cause failure (ICDE); Banco de datos internacional de sucesos de fallo de causa comun (ICDE)

    Energy Technology Data Exchange (ETDEWEB)

    Morales, M. R.; Fernandez Andujar, B.; Pereira, M. B.

    2013-09-01

    A Common Cause Failure (CCF) is a dependent event in which two or more components fail simultaneously or short space of time as a direct result of a shared common cause. The shared cause may be functional or physical. Due to the low frequency of this type of events, some Member States of the Agency of Nuclear Energy (NEA) of the Organization for Cooperation and Economic Development (OECD) decided to create the project International Common-Cause Failure Data Exchange (ICDE) in order to encourage multilateral cooperation in the collection and analysis of data relating to CCF events. (Author)

  15. Anatomy of the ICDS series: A bibliometric analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cardona, Manuel [Max Planck Institute for Solid State Research, Heisenbergstrasse 1, D-70569 Stuttgart (Germany)], E-mail: m.cardona@fkf.mpg.de; Marx, Werner [Max Planck Institute for Solid State Research, Heisenbergstrasse 1, D-70569 Stuttgart (Germany)

    2007-12-15

    In this article, the proceedings of the International Conferences on Defects in Semiconductors (ICDS) have been analyzed by bibliometric methods. The papers of these conferences have been published as articles in regular journals or special proceedings journals and in books with diverse publishers. The conference name/title changed several times. Many of the proceedings did not appear in the so-called 'source journals' covered by the Thomson/ISI citation databases, in particular by the Science Citation Index (SCI). But the number of citations within these source journals can be determined using the Cited Reference Search mode under the Web of Science (WoS) and the SCI offered by the host STN International. The search functions of both systems were needed to select the papers published as different document types and to cover the full time span of the series. The most cited ICDS papers were identified, and the overall numbers of citations as well as the time-dependent impact of these papers, of single conferences, and of the complete series, was established. The complete of citing papers was analyzed with respect to the countries of the citing authors, the citing journals, and the ISI subject categories.

  16. ICD 10 Based Medical Expert System Using Fuzzy Temporal Logic

    Directory of Open Access Journals (Sweden)

    P.Chinniah

    2009-12-01

    Full Text Available Medical diagnosis process involves many levels and considerable amount of time and money are invariably spent for the first level of diagnosis usually made by the physician for all the patients every time. Hence there is a need for a computer based system which not only asks relevant questions to the patients but also aids the physician by giving a set of possible diseases from the symptoms obtained using logic at inference. In this work, an ICD10 based Medical Expert System that provides advice, information and recommendation to the physician using fuzzy temporal logic. The knowledge base used in this system consists of facts of symptoms and rules on diseases. It also provides fuzzy severity scale and weight factor for symptom and disease and can vary with respect to time. The system generates the possible disease conditions based on modified Euclidean metric using Elder’s algorithm for effective clustering. The minimum similarity value is used as the decision parameter to identify a disease. Keywords -Fuzzy clustering, symptoms, fuzzy severity scale, weight factor, Minkowski distance, ICD, WHO, Rules Base, TSQL

  17. Anatomy of the ICDS series: A bibliometric analysis

    Science.gov (United States)

    Cardona, Manuel; Marxa, Werner

    2007-12-01

    In this article, the proceedings of the International Conferences on Defects in Semiconductors (ICDS) have been analyzed by bibliometric methods. The papers of these conferences have been published as articles in regular journals or special proceedings journals and in books with diverse publishers. The conference name/title changed several times. Many of the proceedings did not appear in the so-called “source journals” covered by the Thomson/ISI citation databases, in particular by the Science Citation Index (SCI). But the number of citations within these source journals can be determined using the Cited Reference Search mode under the Web of Science (WoS) and the SCI offered by the host STN International. The search functions of both systems were needed to select the papers published as different document types and to cover the full time span of the series. The most cited ICDS papers were identified, and the overall numbers of citations as well as the time-dependent impact of these papers, of single conferences, and of the complete series, was established. The complete of citing papers was analyzed with respect to the countries of the citing authors, the citing journals, and the ISI subject categories.

  18. Disorders related to sexuality and gender identity in the ICD-11: revising the ICD-10 classification based on current scientific evidence, best clinical practices, and human rights considerations.

    Science.gov (United States)

    Reed, Geoffrey M; Drescher, Jack; Krueger, Richard B; Atalla, Elham; Cochran, Susan D; First, Michael B; Cohen-Kettenis, Peggy T; Arango-de Montis, Iván; Parish, Sharon J; Cottler, Sara; Briken, Peer; Saxena, Shekhar

    2016-10-01

    In the World Health Organization's forthcoming eleventh revision of the International Classification of Diseases and Related Health Problems (ICD-11), substantial changes have been proposed to the ICD-10 classification of mental and behavioural disorders related to sexuality and gender identity. These concern the following ICD-10 disorder groupings: F52 Sexual dysfunctions, not caused by organic disorder or disease; F64 Gender identity disorders; F65 Disorders of sexual preference; and F66 Psychological and behavioural disorders associated with sexual development and orientation. Changes have been proposed based on advances in research and clinical practice, and major shifts in social attitudes and in relevant policies, laws, and human rights standards. This paper describes the main recommended changes, the rationale and evidence considered, and important differences from the DSM-5. An integrated classification of sexual dysfunctions has been proposed for a new chapter on Conditions Related to Sexual Health, overcoming the mind/body separation that is inherent in ICD-10. Gender identity disorders in ICD-10 have been reconceptualized as Gender incongruence, and also proposed to be moved to the new chapter on sexual health. The proposed classification of Paraphilic disorders distinguishes between conditions that are relevant to public health and clinical psychopathology and those that merely reflect private behaviour. ICD-10 categories related to sexual orientation have been recommended for deletion from the ICD-11.

  19. In situ simulation comparing in-hospital first responder sudden cardiac arrest resuscitation using semiautomated defibrillators and automated external defibrillators.

    Science.gov (United States)

    Kobayashi, Leo; Dunbar-Viveiros, Jennifer A; Sheahan, Bethany A; Rezendes, Megan H; Devine, Jeffrey; Cooper, Mary R; Martin, Peggy B; Jay, Gregory D

    2010-04-01

    Multifaceted approaches using simulation and human factors methods may optimize in-hospital sudden cardiac arrest (SCA) response. The Arrhythmia Simulation/Cardiac Event Nursing Training-Automated External Defibrillator phase (ASCENT-AED) study used in situ medical simulation to compare traditional and AED-supplemented SCA first-responder models. The study was conducted at an academic 719-bed hospital with institutional review board approval. Two simulation scenarios were developed and featured either respiratory arrest with perfusing bradycardia or ventricular fibrillation (VF) arrest. Study floors were equipped with either a semiautomated defibrillator (SD) only (control) or with both SD and AED (experimental); subjects functioned as solitary first responders and did not receive resuscitation training. Fifty nurses were enrolled on control (n=25) and experimental (n=25) floors. The groups' nonblinded performances exhibited the following differences during VF scenario: slower calls for help by the control group [mean time to completion of 25+/-17 seconds versus 18+/-11 seconds for the experimental group (P<0.05)] and fewer subjects in the control group performing chest compressions [44.0% versus experimental group's 95.8% (P<0.001)]. Eighty-eight percent of the control group defibrillated the manikin at an average of 155+/-59 seconds, with 32.0% of those subjects using semiautomated rhythm analysis; 100% (not significant [NS]) of experimental group defibrillated at 154+/-72 seconds (NS) with 100% AED analysis (P<0.001). Fewer control group subjects (28.0%) were observed during the bradycardia scenarios to perform inappropriate chest compressions than the AED-supplemented subjects [69.6% (P=0.01)]; nonindicated defibrillation was delivered during these scenarios by a single subject in the control group. Twenty-eight percent and 72% of VF scenarios were managed appropriately by control and experimental groups, respectively; bradycardia scenarios were managed without

  20. 76 FR 51985 - ICD-9-CM Coordination and Maintenance Committee Meeting

    Science.gov (United States)

    2011-08-19

    ... Implantable meshes. ICD-10-CM Diagnosis Topics Aggressive periodontitis. Chronic Fatigue Syndrome. Chronic periodontitis. Gingival recession. Agenda items are subject to change as priorities dictate. Note: CMS and...

  1. 77 FR 48985 - Notice of Meeting of the ICD-9-CM Coordination and Maintenance Committee

    Science.gov (United States)

    2012-08-15

    ... ICD-10-CM Diagnosis Topics: Age related macular degeneration Bilateral mononeuropathy Bilateral option for cerebrovascular codes Chronic Fatigue Syndrome Complications of urinary devices Diabetic...

  2. [Uterine defibrillation in uterine inertia. Report of 2 cases].

    Science.gov (United States)

    Viñals, F; Correa, G; Quiroz, V

    1993-01-01

    The uterine atony are the most common cause of postpartum hemorrhage. Manual compression and pharmacologic methods are usually used with a successful result. When pharmacologic methods fail to control hemorrhage from atony, surgical measures should be undertaken to arrest the bleeding before it becomes life-threatening. We presents the utilization of electrical uterine defibrillation in two cases with acute hemorrhage confirming the effectivity of the proceeding.

  3. The Cause and Mechanism of Cardiac Electrical Instability. Defibrillation Mechanism

    Directory of Open Access Journals (Sweden)

    Rustam G. Habchabov

    2012-06-01

    Full Text Available The reason for the ominous arrhythmias pathway, causing sudden somatic death from cardiovascular diseases is still not clear, cardiological examinations of this phenomenon are conducted throughout the world. Laceration of connective insulating tissue membrane of heart pathway with ectopic nodes oxidation may cause ominous arrhythmias; nobody has considered this cause as a cardiac electrical instability before. Defibrillator electric discharges cannot penetrate into myocardium due to the connective insulating tissue membrane, nobody has considered nervous system, transmitting electricity.

  4. Lingular pneumonia obscured by implanted cardioverter-defibrillator: Lateral thinking.

    Science.gov (United States)

    Sewell, Laura; Harries, Ivan; Chandrasekaran, Barinathan

    2015-01-01

    A 56-year-old female with an implanted cardioverter-defibrillator was admitted with a short history suggestive of a diagnosis of pneumonia. An AP radiograph did not identify an area of consolidation. A subsequent lateral radiograph highlighted an extensive left-lingular-lobe consolidation that had been obscured by the cardiac device. This case highlights the fact that large devices can obscure significant pathology, and that lateral or cross-sectional imaging may be helpful in reaching a diagnosis.

  5. Lingular pneumonia obscured by implanted cardioverter-defibrillator: Lateral thinking

    OpenAIRE

    Laura Sewell, MD; Ivan Harries, MD; Barinathan Chandrasekaran, MD

    2015-01-01

    A 56-year-old female with an implanted cardioverter-defibrillator was admitted with a short history suggestive of a diagnosis of pneumonia. An AP radiograph did not identify an area of consolidation. A subsequent lateral radiograph highlighted an extensive left-lingular-lobe consolidation that had been obscured by the cardiac device. This case highlights the fact that large devices can obscure significant pathology, and that lateral or cross-sectional imaging may be helpful in reaching a diag...

  6. Normativity under change: Older persons with implantable cardioverter defibrillator.

    Science.gov (United States)

    Svanholm, Jette Rolf; Nielsen, Jens Cosedis; Mortensen, Peter Thomas; Christensen, Charlotte Fuglesang; Birkelund, Regner

    2016-05-01

    In modern society, death has become 'forbidden' fed by the medical technology to conquer death. The technological paradigm is challenged by a social-liberal political ideology in postmodern Western societies. The question raised in this study was as follows: Which arguments, attitudes, values and paradoxes between modern and postmodern tendencies concerning treatment and care of older persons with an implantable cardioverter defibrillator appear in the literature? The aim of this study was to describe and interpret how the field of tension concerning older persons with an implantable cardioverter defibrillator - especially end-of-life issues - has been expressed in the literature throughout the last decade. Paul Ricoeur's reflexive interpretive approach was used to extract the meaningful content of the literature involving qualitative, quantitative and normative literature. Analysis and interpretation involved naive reading, structural analysis and critical interpretation. The investigation complied with the principles outlined in the Declaration of Helsinki. The unifying theme was 'Normativity under change'. The sub-themes were 'Death has become legitimate', 'The technological imperative is challenged' and 'Patients and healthcare professionals need to talk about end-of-life issues'. There seems to be a considerable distance between the normative approach of how practice ought to be and findings in empirical studies. Modern as well as postmodern attitudes and perceptions illustrate contradictory tendencies regarding deactivation of the implantable cardioverter defibrillator and replacement of the implantable cardioverter defibrillator in older persons nearing the end of life. The tendencies challenge each other in a struggle to gain position. On the other hand, they can also complement each other because professionalism and health professional expertise cannot stand alone when the patient's life is at stake but must be unfolded in an alliance with the patient who

  7. The role of automated external defibrillators in dental practice.

    Science.gov (United States)

    Boyd, Barry C; Fantuzzo, Joseph J; Votta, Timothy

    2006-01-01

    Dental practices are seeing an increasing number of elderly and medically compromised patients, making it likely that staff will be called upon to respond to medical emergencies in the office, including cardiac arrest. Out-of-hospital cardiac arrests account for nearly half of all cardiovascular deaths in the United States. In adult cardiac arrest victims, the most frequent cause of sudden cardiac arrest is ventricular dysrhythmia, either ventricular tachycardia or ventricular fibrillation. The survival rate for sufferers of out-of-hospital cardiac arrests is a dismal 1% to 5% to hospital discharge. A majority of people who survive to discharge sustain significant morbidity. Untreated ventricular fibrillation degenerates into asystole, which is often refractory to resuscitative efforts and represents a terminal event. The development and availability of the automated external defibrillator (AED) represents a promising advance in the pre-hospital early defibrillation of victims of sudden cardiac arrest in a variety of settings, often remote from hospitals or EMS personnel. Given the medically compromised segment of the population treated in many dental practices today, it is imperative that dental practitioners and allied health providers become trained in the recognition and prompt initiation of emergency care, including basic life support with early defibrillation. The AED is becoming more accessible, with increasingly widespread availability, training in its use and relative ease of operation, making the goal of increased survival one in which dental health professionals can play a part.

  8. Estimation of current density distribution under electrodes for external defibrillation

    Directory of Open Access Journals (Sweden)

    Papazov Sava P

    2002-12-01

    Full Text Available Abstract Background Transthoracic defibrillation is the most common life-saving technique for the restoration of the heart rhythm of cardiac arrest victims. The procedure requires adequate application of large electrodes on the patient chest, to ensure low-resistance electrical contact. The current density distribution under the electrodes is non-uniform, leading to muscle contraction and pain, or risks of burning. The recent introduction of automatic external defibrillators and even wearable defibrillators, presents new demanding requirements for the structure of electrodes. Method and Results Using the pseudo-elliptic differential equation of Laplace type with appropriate boundary conditions and applying finite element method modeling, electrodes of various shapes and structure were studied. The non-uniformity of the current density distribution was shown to be moderately improved by adding a low resistivity layer between the metal and tissue and by a ring around the electrode perimeter. The inclusion of openings in long-term wearable electrodes additionally disturbs the current density profile. However, a number of small-size perforations may result in acceptable current density distribution. Conclusion The current density distribution non-uniformity of circular electrodes is about 30% less than that of square-shaped electrodes. The use of an interface layer of intermediate resistivity, comparable to that of the underlying tissues, and a high-resistivity perimeter ring, can further improve the distribution. The inclusion of skin aeration openings disturbs the current paths, but an appropriate selection of number and size provides a reasonable compromise.

  9. ICD-10在中国的引进和推广%Introduction and Promotion of ICD-10 in China

    Institute of Scientific and Technical Information of China (English)

    于欣

    2009-01-01

    在1948年世界卫生组织出版的《国际疾病分类第六版》中,精神障碍被首次纳入。在1975年颁布ICD-9后,WHO着手开始ICD-10的筹备工作。筹备工作是以几项重大的科研计划开展为标志的:①编制了“复合性国际诊断交谈检查(CIDI)”,适用于在不同国家的一般人群中进行精神障碍的流行病学研究,目前CIDI的版本已经更新到3.0;②编制了适用于临床工作者使用的评定工具“神经精神病学临床评定表(SCAN)”,用于专业人员临床评估病人;③编制了适用于不同国家的人格障碍评定工具“国际人格障碍检查”(International Personality Disorder Examination,IPDE)。

  10. Therapeutic options in chronic heart failure. Findings on chest X-ray; Nicht medikamentoese Therapieoptionen der chronischen Herzinsuffizienz. Befunde in der Projektionsradiografie des Thorax

    Energy Technology Data Exchange (ETDEWEB)

    Granitz, M.R.; Meissnitzer, T.; Meissnitzer, M.W.; Hergan, K.; Altenberger, J.; Granitz, C. [Uniklinikum Salzburg - Landeskrankenhaus (Austria)

    2016-05-15

    The contribution covers drugless therapeutic options for chronic heart failure: the implantable cardioverter/defibrillator (ICD), the cardiac resynchronization therapy (CRT), the interventional catheter treatment of functional mitral insufficiency, and mechanical heart supporting systems and heart transplantation.

  11. Estimation of the Alpha Factor Parameters Using the ICDE Database

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dae Il; Hwang, M. J.; Han, S. H

    2007-04-15

    Detailed common cause failure (CCF) analysis generally need for the data for CCF events of other nuclear power plants because the CCF events rarely occur. KAERI has been participated at the international common cause failure data exchange (ICDE) project to get the data for the CCF events. The operation office of the ICDE project sent the CCF event data for EDG to the KAERI at December 2006. As a pilot study, we performed the detailed CCF analysis of EDGs for Yonggwang Units 3 and 4 and Ulchin Units 3 and 4 using the ICDE database. There are two onsite EDGs for each NPP. When an offsite power and the two onsite EDGs are not available, one alternate AC (AAC) diesel generator (hereafter AAC) is provided. Two onsite EDGs and the AAC are manufactured by the same company, but they are designed differently. We estimated the Alpha Factor and the CCF probability for the cases where three EDGs were assumed to be identically designed, and for those were assumed to be not identically designed. For the cases where three EDGs were assumed to be identically designed, double CCF probabilities of Yonggwang Units 3/4 and Ulchin Units 3/4 for 'fails to start' were estimated as 2.20E-4 and 2.10E-4, respectively. Triple CCF probabilities of those were estimated as 2.39E-4 and 2.42E-4, respectively. As each NPP has no experience for 'fails to run', Yonggwang Units 3/4 and Ulchin Units 3/4 have the same CCF probability. The estimated double and triple CCF probabilities for 'fails to run' are 4.21E-4 and 4.61E-4, respectively. Quantification results show that the system unavailability for the cases where the three EDGs are identical is higher than that where the three EDGs are different. The estimated system unavailability of the former case was increased by 3.4% comparing with that of the latter. As a future study, a computerization work for the estimations of the CCF parameters will be performed.

  12. Preparing for ICD-10-CM/PCS implementation: impact on productivity and quality.

    Science.gov (United States)

    Stanfill, Mary H; Hsieh, Kang Lin; Beal, Kathleen; Fenton, Susan H

    2014-01-01

    Coding productivity is expected to drop significantly during the lead-up to and in the initial stages of ICD-10-CM/PCS implementation, now expected to be delayed until October 1, 2015. This study examined the differences in coding productivity between ICD-9-CM and ICD-10-CM/PCS for hospital inpatient cases matched for complexity and severity. Additionally, interrater reliability was calculated to determine the quality of the coding. On average, coding of an inpatient record took 17.71 minutes (69 percent) longer with ICD-10-CM/PCS than with ICD-9-CM. A two-tailed T-test for statistical validity for independent samples was significant (p = .001). No coder characteristics such as years of experience or educational level were found to be a significant factor in coder productivity. Coders who had received more extensive training were faster than coders who had received only basic training. Though this difference was not statistically significant, it provides a strong indication of significant return on investment for staff training time. Coder interrater reliability was substantial for ICD-9-CM but only moderate for ICD-10-CM/PCS, though some ICD-10-CM/PCS cases had complete interrater (coder) agreement. Time spent coding a case was negatively correlated with interrater reliability (-0.425 for ICD-10-CM and -0.349 for ICD-10-PCS). This finding signals that increased time per case does not necessarily translate to higher quality. Adequate training for coders, as well as guidance regarding time invested per record, is important. Additionally, these findings indicate that previous estimates of initial coder productivity loss with ICD-10-CM/PCS may have been understated.

  13. Trends in Gastroenteritis-associated Mortality in the United States 1985-2005: Variations by ICD-9 and ICD-10 Codes

    Science.gov (United States)

    BackgroundTrends in gastroenteritis-associated mortality are changing over time with development of antibiotic resistant strains of certain pathogens, improved diagnostic methods, and changing healthcare. In 1999, ICD-10 coding was introduced for mortality records which can also ...

  14. ICD 10 Based Medical Expert System Using Fuzzy Temporal Logic

    CERN Document Server

    Chinniah, P

    2010-01-01

    Medical diagnosis process involves many levels and considerable amount of time and money are invariably spent for the first level of diagnosis usually made by the physician for all the patients every time. Hence there is a need for a computer based system which not only asks relevant questions to the patients but also aids the physician by giving a set of possible diseases from the symptoms obtained using logic at inference. In this work, an ICD10 based Medical Expert System that provides advice, information and recommendation to the physician using fuzzy temporal logic. The knowledge base used in this system consists of facts of symptoms and rules on diseases. It also provides fuzzy severity scale and weight factor for symptom and disease and can vary with respect to time. The system generates the possible disease conditions based on modified Euclidean metric using Elders algorithm for effective clustering. The minimum similarity value is used as the decision parameter to identify a disease.

  15. Effects of n-3 polyunsaturated fatty acids on malignant ventricular arrhythmias in patients with chronic heart failure and implantable cardioverter-defibrillators: A substudy of the Gruppo Italiano per lo Studio della Sopravvivenza nell'Insufficienza Cardiaca (GISSI-HF) trial.

    Science.gov (United States)

    Finzi, Andrea A; Latini, Roberto; Barlera, Simona; Rossi, Maria G; Ruggeri, Albarosa; Mezzani, Alessandro; Favero, Chiara; Franzosi, Maria G; Serra, Domenico; Lucci, Donata; Bianchini, Francesca; Bernasconi, Roberto; Maggioni, Aldo P; Nicolosi, Gianluigi; Porcu, Maurizio; Tognoni, Gianni; Tavazzi, Luigi; Marchioli, Roberto

    2011-02-01

    The antiarrhythmic effects of n-3 polyunsaturated fatty acids (n-3PUFA) in ischemic heart disease have been demonstrated; however, studies in patients surviving malignant ventricular arrhythmias of different etiologies treated with an implantable cardioverter-defibrillator (ICD) have given conflicting results. The purpose of this study was to assess the antiarrhythmic effect of n-3PUFA versus placebo in 566 patients with heart failure enrolled in the GISSI-HF trial who received an ICD for secondary or primary prevention of ventricular fibrillation (VF) or tachycardia (VT). Clinical data and arrhythmic event recordings extracted from the device memory were obtained. We tested the treatment effect by a multivariate Cox model adjusting for all clinical parameters associated with the primary end point defined as time to first appropriate ICD discharge for VT/VF. In the 566 patients with at least one recorded follow-up visit, 1363 VT and 316 VF episodes were terminated by ICD pacing or shock over a median follow-up of 928 days. The incidence of the primary end point event was 27.3% in the n-3PUFA group and 34.0% in the placebo group (adjusted hazard rate = 0.80, 95% CI 0.59-1.09, P = .152). Patients who received 1, 2 to 3, or >3 ICD discharges were 8.9%, 7.1%, and 11.1% in the n-3PUFA group, compared with slightly higher rates of 11.1%, 10.7%, and 12.1% in the placebo group (overall P = .30). Patients with the highest 3-month increase in plasma n-3PUFA had a somewhat lower incidence of arrhythmic events. The results of this study, though not statistically significant, support prior evidences of an antiarrhythmic effect of n-3PUFA in patients with ICD, although they leave open the issue of whether this effect leads to a survival benefit. Copyright © 2011 Mosby, Inc. All rights reserved.

  16. 应用 ICD 编码提高入出院诊断符合率%Improve the Accuracy of Diagnosis Coincidence Rate by ICD

    Institute of Scientific and Technical Information of China (English)

    王志国; 朱佳怀; 邹郢; 黄丽丽; 朱智明

    2015-01-01

    Objective The aim is to improve the accuracy of diagnosis coincidence rate with ICD assis -tance judgment.Methods The data of diagnosis were extracted from Hospital Information System .The difference between physician judgment and ICD code judgment was compared , the inconsistent cases were analyzed .Results The coincidence rate judged by ICD code was higher than that judged by physician (99.21% vs.54.31%,P <0.0001).Of all the 2145 cases, 70 cases judged by physician were wrong .Conclusion With the assistance judg-ment of ICD can improve the accuracy of diagnosis coincidence rate .%目的:以国际疾病分类编码(ICD10)辅助判定提高患者出入院诊断符合率的准确性。方法从“军字一号”数据库中提取诊断符合相关数据,比较医师判定和 ICD10判定入院诊断符合的一致性,并对两种判定不一致的病例进行分析。结果2145例次出院患者的 ICD 编码诊断符合率判定(99.21%)明显高于医师判定(54.31%,P <0.0001),有70例为医师判定错误。结论以 ICD 编码进行辅助判定,有助于提高患者入出院诊断符合率的准确性,提高诊断质量。

  17. On the road to DSM-V and ICD-11.

    Science.gov (United States)

    Kupfer, David J; Regier, Darrel A; Kuhl, Emily A

    2008-11-01

    Development of the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-V) has been ongoing since 1994, though official release will not occur for another 4 years. Potential revisions are being derived from multiple sources, including building on perceived limitations of DSM-IV; broad-based literature reviews; secondary and primary data analyses; and discussions between global members of the mental health community. The current focus on aligning DSM with the International Classification of Diseases-11 (ICD-11) speaks to the importance of creating a unified text that embraces cross-cutting issues of diagnostics, such as developmental, age-related, and cultural phenomena. International discourse is vital to this process and has been fostered by a National Institutes of Health-sponsored conference series on diagnosis-specific topics. From this series, the DSM-V Task Force developed the following set of revision principals to guide the efforts of the DSM-V Work Groups: grounding recommendations in empirical evidence; maintaining continuity with previous editions of DSM; removing a priori limitations on the amount of changes DSM-V may incur; and maintaining DSM's status as a living document. With work group formation complete, members are currently carrying out the research and revision recommendations proposed during the conference series. Ongoing activities include adding specialized advisors to each work group; completing literature reviews and planning data analyses; and forming study groups to discuss integration of cross-cutting issues (e.g., developmental lifespan factors; formation of diagnostic spectra). The road to DSM-V and ICD-11 has been challenging, but members continue to work diligently in their goal of constructing the most harmonious, scientifically sound, and clinically relevant DSM to date.

  18. Phantom shocks in patients with implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Berg, Selina Kikkenborg; Moons, Philip; Zwisler, Ann-Dorthe;

    2013-01-01

    of phantom shocks.METHODS AND RESULTS: The design was secondary explorative analyses of data from a randomized controlled trial. One hundred and ninety-six patients with first-time ICD implantation (79% male, mean age 58 years) were randomized (1 : 1) to either combined rehabilitation or a control group...

  19. Spinal cord stimulation for refractory angina in a patient implanted with a cardioverter defibrillator.

    Science.gov (United States)

    Ferrero, Paolo; Grimaldi, Roberto; Massa, Riccardo; Chiribiri, Amedeo; De Luca, Anna; Castellano, Maddalena; Cardano, Paola; Trevi, Gian Paolo

    2007-01-01

    Spinal cord stimulation is currently used to treat refractory angina. Some concerns may arise about the possible interaction concerning the spinal cord stimulator in patients already implanted with a pacemaker or a cardioverter defibrillator. We are going to describe the successful implantation of a spinal cord stimulator in a patient previously implanted with a cardioverter defibrillator.

  20. [First responder defibrillation in the USA, Europe and Germany--prerequisites, experiences, perspectives].

    Science.gov (United States)

    Trappe, H-J

    2005-06-01

    Sudden out-of-hospital cardiac arrest is a leading cause of death and only 5-8% of patients survive such event. Defibrillation is the mose effective treatment and should performed within 5 minutes; however, its effectiveness diminishes with each passing minute. "Early defibrillation" is the use of automated external defibrillators (AEDs) by trained public-safety personnal ("first responder"), whereas "public access" defibrillation describes AED use by persons who have no specific AED training. Several studies in the US and in Europe show that first responder defibrillation will increase the number of survivors of out-of-hospital cardiac arrest compared to paramedics. This is caused by a shorter "call-to-arrival-time" in first responders compared to paramedics. In Europe, programs for the use of automated external defibrillators exist only occasionally. Reasons for this are the lack of open-mindedness, logistic and legal problems. In Germany, there are only few AED programs with promising results. At the present time, placement of automated external defibrillators in public places frequented by a large number of susceptible people will increase overall survival. However, placement of AEDs in all public places is still debatable and further studies are necessary to estimate the potential impact of publicc access defibrillators.

  1. Systematic review of validated case definitions for diabetes in ICD-9-coded and ICD-10-coded data in adult populations.

    Science.gov (United States)

    Khokhar, Bushra; Jette, Nathalie; Metcalfe, Amy; Cunningham, Ceara Tess; Quan, Hude; Kaplan, Gilaad G; Butalia, Sonia; Rabi, Doreen

    2016-08-05

    With steady increases in 'big data' and data analytics over the past two decades, administrative health databases have become more accessible and are now used regularly for diabetes surveillance. The objective of this study is to systematically review validated International Classification of Diseases (ICD)-based case definitions for diabetes in the adult population. Electronic databases, MEDLINE and Embase, were searched for validation studies where an administrative case definition (using ICD codes) for diabetes in adults was validated against a reference and statistical measures of the performance reported. The search yielded 2895 abstracts, and of the 193 potentially relevant studies, 16 met criteria. Diabetes definition for adults varied by data source, including physician claims (sensitivity ranged from 26.9% to 97%, specificity ranged from 94.3% to 99.4%, positive predictive value (PPV) ranged from 71.4% to 96.2%, negative predictive value (NPV) ranged from 95% to 99.6% and κ ranged from 0.8 to 0.9), hospital discharge data (sensitivity ranged from 59.1% to 92.6%, specificity ranged from 95.5% to 99%, PPV ranged from 62.5% to 96%, NPV ranged from 90.8% to 99% and κ ranged from 0.6 to 0.9) and a combination of both (sensitivity ranged from 57% to 95.6%, specificity ranged from 88% to 98.5%, PPV ranged from 54% to 80%, NPV ranged from 98% to 99.6% and κ ranged from 0.7 to 0.8). Overall, administrative health databases are useful for undertaking diabetes surveillance, but an awareness of the variation in performance being affected by case definition is essential. The performance characteristics of these case definitions depend on the variations in the definition of primary diagnosis in ICD-coded discharge data and/or the methodology adopted by the healthcare facility to extract information from patient records. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. Systematic review of validated case definitions for diabetes in ICD-9-coded and ICD-10-coded data in adult populations

    Science.gov (United States)

    Khokhar, Bushra; Jette, Nathalie; Metcalfe, Amy; Cunningham, Ceara Tess; Kaplan, Gilaad G; Butalia, Sonia; Rabi, Doreen

    2016-01-01

    Objectives With steady increases in ‘big data’ and data analytics over the past two decades, administrative health databases have become more accessible and are now used regularly for diabetes surveillance. The objective of this study is to systematically review validated International Classification of Diseases (ICD)-based case definitions for diabetes in the adult population. Setting, participants and outcome measures Electronic databases, MEDLINE and Embase, were searched for validation studies where an administrative case definition (using ICD codes) for diabetes in adults was validated against a reference and statistical measures of the performance reported. Results The search yielded 2895 abstracts, and of the 193 potentially relevant studies, 16 met criteria. Diabetes definition for adults varied by data source, including physician claims (sensitivity ranged from 26.9% to 97%, specificity ranged from 94.3% to 99.4%, positive predictive value (PPV) ranged from 71.4% to 96.2%, negative predictive value (NPV) ranged from 95% to 99.6% and κ ranged from 0.8 to 0.9), hospital discharge data (sensitivity ranged from 59.1% to 92.6%, specificity ranged from 95.5% to 99%, PPV ranged from 62.5% to 96%, NPV ranged from 90.8% to 99% and κ ranged from 0.6 to 0.9) and a combination of both (sensitivity ranged from 57% to 95.6%, specificity ranged from 88% to 98.5%, PPV ranged from 54% to 80%, NPV ranged from 98% to 99.6% and κ ranged from 0.7 to 0.8). Conclusions Overall, administrative health databases are useful for undertaking diabetes surveillance, but an awareness of the variation in performance being affected by case definition is essential. The performance characteristics of these case definitions depend on the variations in the definition of primary diagnosis in ICD-coded discharge data and/or the methodology adopted by the healthcare facility to extract information from patient records. PMID:27496226

  3. What happened to harmonization of the PTSD diagnosis? The divergence of ICD11 and DSM5.

    Science.gov (United States)

    Bisson, J I

    2013-09-01

    The development of ICD11 and DSM5 was seen as an opportunity to harmonize the two major classification systems for mental disorders. The proposed ICD11 and DSM5 diagnostic criteria for PTSD are markedly different. The implications of this remain to be seen, but have the potential to cause confusion to PTSD sufferers, clinicians, researchers and others impacted on by the condition.

  4. The Capacity of ICD-10-CM/PCS to Characterize Surgical Care.

    Science.gov (United States)

    Utter, Garth H; Schuster, Kevin M; Miller, Preston R; Mowery, Nathan T; Agarwal, Suresh K; Winchell, Robert J; Crandall, Marie L

    2017-05-22

    The International Classification of Diseases, 10th edition, Clinical Modification and Procedure Coding System (ICD-10-CM/PCS) have been in effect since October 1, 2015 and offer much greater capacity than previous classifications to characterize the nature and treatment of surgical conditions. However, the diagnosis codes of ICD-10-CM are unevenly specific across the spectrum of surgical conditions and currently do not adequately allow description of important distinctions in disease severity for many common surgical conditions. Through our work on the Patient Assessment Committee of the American Association for the Surgery of Trauma, we sought changes to ICD-10-CM to allow for better characterization of the severity of several common emergency general surgical conditions, such as acute appendicitis and acute pancreatitis. The ICD Coordination and Maintenance Committee periodically entertains requests to improve ICD-10-CM/PCS through a formal process with public input; the Centers for Medicare and Medicaid services, in coordination with other agencies and organizations, issue annual updates to these classifications. We describe some potential improvements to ICD-10-CM/PCS as well as how individuals and organizations can propose and effect such changes. With the next parent classification for mortality reporting (ICD-11) currently in development by the World Health Organization, now is also an opportune time to request changes that eventually would be incorporated into the future U.S. version of ICD-11 for morbidity reporting.

  5. Wavelength sensitive detector based on ICD in two coupled quantum wells

    Science.gov (United States)

    Goldzak, Tamar; Gilary, Ido; Moiseyev, Nimrod

    2014-05-01

    We design a wavelength sensitive detector based on inter coulombic decay (ICD) mechanism in a two-quantum well nano-structure. The two coupled quantum wells are designed to satisfy the specific conditions which allow the ICD to occur. In this setup, by absorbing light an electron in one well is excited. Its relaxation back to the ground state is a non-radiative process which transfers the excess energy to the ionization of the electron in the neighboring well into the continuum. Only radiation with a specific wavelength will be absorbed, when the wavelength matches the excitation energy in the quantum well. By applying a weak bias a current is obtained even when light with a very low intensity is absorbed. For the ICD to be dominant decay mechanism it must prevail over all other possible competitive decay processes. We have found that the lifetime of the ICD is on the timescale of picoseconds. Control over the ICD lifetime can be achieved by variation of different parameters in the two quantum well nano-structure. The most useful parameter is the distance between the two quantum wells. We show that as the distance decreases the decay rate of the ICD increases. Furthermore the distance can be tuned such that the emitted electron would be in a metastable state in the continuum (a resonance state); this causes the life time of the ICD to be an order of magnitude smaller, and improves the efficiency of the ICD.

  6. A proposal for a standard communication protocol for pacemaker/ICD programmers

    NARCIS (Netherlands)

    Dijk, WA; Hooijschuur, CAM; van der Velde, W; Dassen, WRM

    2005-01-01

    The information generated by pacemakers and ICD's to support the cardiologist and technician for installing the optimal settings for the patient is increasing rapidly. In this paper a proposal is described for electronic data exchange between the pacemaker/ICD programmers and electronic information

  7. Patient perceptions of implantable cardioverter-defibrillator deactivation discussions: A qualitative study

    Directory of Open Access Journals (Sweden)

    Jane MacIver

    2016-04-01

    Full Text Available Background: There is a class I recommendation for implantable cardioverter-defibrillator deactivation discussions to occur between physicians and heart failure patients. Few studies have reported the patient’s perspective on the timing of implantable cardioverter-defibrillator deactivation discussions. Aim: To determine patient awareness, preferences and timing of implantable cardioverter-defibrillator deactivation discussions. Design: Grounded theory was used to collect and analyze interview data from 25 heart failure patients with an implantable cardioverter-defibrillator. Setting and participants: Patients with an implantable cardioverter-defibrillator, from the Heart Function Clinic at University Health Network (Toronto, Canada. Results: The sample (n = 25 was predominately male (76% with an average age of 62 years. Patients identified three stages where they felt implantable cardioverter-defibrillator deactivation should be discussed: (1 prior to implantation, (2 with any significant deterioration but while they were of sound mind to engage in and communicate their preferences and (3 at end of life, where patients wished further review of their previously established preferences and decisions about implantable cardioverter-defibrillator deactivation. Most patients (n = 17, 68% said they would consider deactivation, six (24% were undecided and two (8% were adamant they would never turn it off. Conclusion: The patient preferences identified in this study support the need to include information on implantable cardioverter-defibrillator deactivation at implant, with change in clinical status and within broader discussions about end-of-life treatment preferences. Using this process to help patients determine and communicate their implantable cardioverter-defibrillator deactivation preferences may reduce the number of patients experiencing distressing implantable cardioverter-defibrillator shocks at end of life.

  8. Acompanhamento clínico de pacientes portadores de cardioversor-desfibrilador implantável Clinical follow-up of patients with implantable cardioverter-defibrillator

    Directory of Open Access Journals (Sweden)

    Silvia Martelo Souza da Fonseca

    2007-01-01

    Full Text Available OBJETIVO: Relatar o perfil de terapias apropriadas (TA e inapropriadas (TI do cardioversores-desfibriladores implantáveis (CDI em portadores de cardiopatia isquêmica e não-isquêmica e as complicações precoces e tardias do procedimento. MÉTODOS: Foram analisados 155 pacientes (119 homens e 36 mulheres, idade média de 47 (21-88 anos, submetidos ao implante de CDI. Foram divididos em grupos I - pacientes pós-infarto agudo do miocárdio (IAM (n = 80, grupo II - cardiopatia não-isquêmica e fração de ejeção de ventrículo esquerdo (FEVE OBJECTIVE: To report appropriate (AT and inappropriate (IT ICD therapies in patients with ischemic and nonischemic heart disease, as well as early and late procedure-related complications. METHODS: One hundred and fifty-five patients (119 male and 36 female, mean age 47 years (21-88, who underwent ICD implantation between 1994 and March 2003 were analyzed. Patients were divided into the following groups: Group I - Post-AMI patients (n = 80; Group II - Patients with nonischemic heart disease and LV ejection fraction < 40% (n = 45, Chagas disease (n = 18, idiopathic dilated cardiomyopathy (n= 12, hypertensive disease (n = 8, hypertrophic cardiomyopathy (n = 4 and valvular heart disease (n = 3; Group III - Patients with arrhythmogenic right ventricular dysplasia (n = 13; and Group IV - Patients with channelopathies: Brugada Syndrome (n = 8 and idiopathic ventricular arrhythmias (n = 9. All patients underwent electrophysiological study (EPS with induction of sustained ventricular arrhythmia ICD implantation. RESULTS: During the 26-month mean follow up, a high rate of appropriate ICD therapies (antitachycardia pacing and/or shock was observed (46% in the four groups, with no statistically significant difference. The four groups did not differ in either overall (8.4% or arrhythmic mortality (1.3%. There was no correlation between appropriate ICD therapies and initial clinical presentation or inducible

  9. Pacemaker, implanted cardiac defibrillator and irradiation: Management proposal in 2010 depending on the type of cardiac stimulator and prognosis and location of cancer; Pacemaker, defibrillateur et radiotherapie: propositions de conduite a tenir en 2010 en fonction du type de stimulateur cardiaque, du pronostic et du site du cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, P. [Service d' anesthesie reanimation, hopital Nord, centre hospitalier universitaire de Saint-etienne, 42055 Saint-etienne cedex 2 (France); Da Costa, A. [Service de cardiologie, hopital Nord, centre hospitalier universitaire de Saint-etienne, 42055 Saint-etienne cedex 2 (France); Marcy, P.Y. [Departement de radiologie, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Kreps, S. [Service de radiotherapie Corad, centre regional universitaire de cancerologie Henry-S.-Kaplan, hopital Bretonneau-2, CHU de Tours, boulevard Tonnelle, 37000 Tours (France); Angellier, G.; Marcie, S.; Bondiau, P.Y. [Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Departement de radiotherapie oncologie, centre CyberKnife, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Briand-Amoros, C. [Service de radiotherapie, hopital europeen Georges-Pompidou, 20, rue Leblanc, 75015 Paris (France); Thariat, J. [Universite Nice Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); Departement de radiotherapie oncologie, centre CyberKnife, centre Antoine-Lacassagne, 33, avenue de Valombrose, 06189 Nice cedex 2 (France); IBDC CNRS UMR 6543, centre Antoine-Lacassagne, universite Sophia-Antipolis, 33, avenue de Valombrose, 06189 Nice cedex 2 (France)

    2011-06-15

    Ionizing radiation may interfere with electric components of pacemakers or implantable cardioverter defibrillators. The type, severity and extent of radiation damage to pacemakers, have previously been shown to depend on the total dose and dose rate. Over 300,000 new cancer cases are treated yearly in France, among which 60% are irradiated in the course of their disease. One among 400 of these patients has an implanted pacemaker or defibrillator. The incidence of pacemaker and implanted cardioverter defibrillator increases in an ageing population. The oncologic prognosis must be weighted against the cardiologic prognosis in a multidisciplinary and transversal setting. Innovative irradiation techniques and technological sophistications of pacemakers and implantable cardioverter-defibrillators (with the introduction of more radiosensitive complementary metal-oxide-semiconductors since 1970) have potentially changed the tolerance profiles. This review of the literature studied the geometric, dosimetric and radiobiological characteristics of the radiation beams for high energy photons, stereotactic irradiation, proton-therapy. Standardized protocols and radiotherapy optimization (particle, treatment fields, energy) are advisable in order to improve patient management during radiotherapy and prolonged monitoring is necessary following radiation therapy. The dose received at the pacemaker/heart should be calculated. The threshold for the cumulated dose to the pacemaker/implantable cardioverter-defibrillator (2 to 5 Gy depending on the brand), the necessity to remove/displace the device based on the dose-volume histogram on dosimetry, as well as the use of lead shielding and magnet are discussed. (authors)

  10. High-dose lidocaine does not affect defibrillation efficacy: implications for defibrillation mechanisms.

    Science.gov (United States)

    Ujhelyi, M R; Sims, J J; Miller, A W

    1998-04-01

    This study assessed the effect of low (10 mg.kg-1.h-1) and very high (18 mg.kg-1.h-1) doses of lidocaine on defibrillation energy requirements (DER) to relate changes in indexes of sodium-channel blockade with changes in DER values using a dose-response study design. In group 1 (control; n = 6 pigs), DER values were determined at baseline and during treatment with 5% dextrose in water (D5W) and with D5W added to D5W. In group 2 (n = 7), DER values were determined at baseline and during treatment with low-dose lidocaine followed by high-dose lidocaine. In group 3 (n = 3), DER values were determined at baseline and high-dose lidocaine. Group 3 controlled for the order of lidocaine treatment with the addition of high-dose lidocaine after baseline. DER values in group 1 did not change during D5W. In group 2, low-dose lidocaine increased DER values by 51% (P = 0.01), whereas high-dose lidocaine added to low-dose lidocaine reduced DER values back to within 6% of baseline values (P = 0.02, low dose vs. high dose). DER values during high-dose lidocaine in group 3 also remained near baseline values (16.2 +/- 2.7 to 12.9 +/- 2.7 J), demonstrating that treatment order had no impact on group 2. Progressive sodium-channel blockade was evident as incremental reduction in ventricular conduction velocity as the lidocaine dose increased. Lidocaine also significantly increased ventricular fibrillation cycle length as the lidocaine dose increased. However, the greatest increase in DER occurred when ventricular fibrillation cycle length was minimally affected, demonstrating a negative correlation (P = 0.04). In summary, lidocaine has an inverted U-shaped DER dose-response curve. At very high lidocaine doses, DER values are similar to baseline and tend to decrease rather than increase. Increased refractoriness during ventricular fibrillation may be the electrophysiological mechanism by which high-dose lidocaine limits the adverse effects that low-dose lidocaine has on DER values

  11. 双硫仑样反应ICD-10编码探讨%Discussion of Disulfiram Like Reaction of ICD-10 Code

    Institute of Scientific and Technical Information of China (English)

    江俊

    2015-01-01

    Objective To summary the key points of coding for disulfiram-like reaction in ICD-10. Methods On the base of introducing pharmacological ef ect of disulfirm and pathogenesis of disulfiram-like reaction,the ways of Coding for Disulfiram-like Reaction in ICD-10 were analyzed. Results The coding are:disulfiram poisoning T50.6,ethanol combined with antibacterial agents or disulfiram T52.8、T65.8.Conclusion It was very important for coding clerks to master the ICD-10 searching methods,learn relevant knowledge about the disease,and careful y read medical records,so as to manage accurately ICD-10 ecoding of disulfiram-like reaction.%目的总结双硫仑样反应ICD-10编码的要点。方法介绍双硫仑的药理作用及双硫仑样反应的发病机制,分析不同原因引起的双硫仑样反应ICD-10编码的方法。结果双硫仑中毒T50.6,抗生素或双硫仑与酒精联用T52.8。结论掌握ICD-10的查找方法,理解双硫仑样反应相关知识,仔细阅读分析病案,是正确编码双硫仑样反应的关键。

  12. Bystander Defibrillation for Out-of-Hospital Cardiac Arrest in Public vs Residential Locations.

    Science.gov (United States)

    Hansen, Steen Møller; Hansen, Carolina Malta; Folke, Fredrik; Rajan, Shahzleen; Kragholm, Kristian; Ejlskov, Linda; Gislason, Gunnar; Køber, Lars; Gerds, Thomas A; Hjortshøj, Søren; Lippert, Freddy; Torp-Pedersen, Christian; Wissenberg, Mads

    2017-05-01

    Bystander-delivered defibrillation (hereinafter referred to as bystander defibrillation) of patients with out-of-hospital cardiac arrests (OHCAs) remains limited despite the widespread dissemination of automated external defibrillators (AEDs). To examine calendar changes in bystander defibrillation and subsequent survival according to a public or a residential location of the cardiac arrest after nationwide initiatives in Denmark to facilitate bystander-mediated resuscitative efforts, including bystander defibrillation. This nationwide study identified 18 688 patients in Denmark with first-time OHCA from June 1, 2001, to December 31, 2012, using the Danish Cardiac Arrest Registry. Patients had a presumed cardiac cause of arrest that was not witnessed by emergency medical services personnel. Data were analyzed from April 1, 2015, to December 10, 2016. Nationwide initiatives to facilitate bystander resuscitative efforts, including bystander defibrillation, consisted of resuscitation training of Danish citizens, dissemination of on-site AEDs, foundation of an AED registry linked to emergency medical dispatch centers, and dispatcher-assisted guidance of bystander resuscitation efforts. The proportion of patients who received bystander defibrillation according to the location of the cardiac arrest and their subsequent 30-day survival. Of the 18 688 patients with OHCAs (67.8% men and 32.2% women; median [interquartile range] age, 72 [62-80] years), 4783 (25.6%) had a cardiac arrest in a public location and 13 905 (74.4%) in a residential location. The number of registered AEDs increased from 141 in 2007 to 7800 in 2012. The distribution of AED location was consistently skewed in favor of public locations. Bystander defibrillation increased in public locations from 3 of 245 (1.2%; 95% CI, 0.4%-3.5%) in 2001 to 78 of 510 (15.3%; 95% CI, 12.4%-18.7%) in 2012 (P bystander defibrillation increased in public locations from 8.3% (95% CI, 1.5%-35.4%) in 2001/2002 to 57

  13. Lingular pneumonia obscured by implanted cardioverter-defibrillator: Lateral thinking

    Directory of Open Access Journals (Sweden)

    Laura Sewell, MD

    2015-01-01

    Full Text Available A 56-year-old female with an implanted cardioverter-defibrillator was admitted with a short history suggestive of a diagnosis of pneumonia. An AP radiograph did not identify an area of consolidation. A subsequent lateral radiograph highlighted an extensive left-lingular-lobe consolidation that had been obscured by the cardiac device. This case highlights the fact that large devices can obscure significant pathology, and that lateral or cross-sectional imaging may be helpful in reaching a diagnosis.

  14. The emergence of devastating impulse control disorders during dopamine agonist therapy of the restless legs syndrome.

    Science.gov (United States)

    Dang, Dien; Cunnington, David; Swieca, John

    2011-01-01

    The Restless Legs Syndrome is a common sensorimotor disorder, typically amenable to treatment with dopamine agonist therapy. Dopamine agonists have been associated with emergent impulse control disorders (ICDs) when used in patients with Parkinson disease, and ICDs have now been reported in individuals with RLS on dopamine agonist therapy. Our aim was to characterize cases of emergent ICDs in Australian patients with focus on the dopamine agonists implicated and the social significance of ICDs. A series of RLS patients on dopamine agonist therapy were identified with ICDs over a 2-year period. Additional cases of ICDs were found using a mailout questionnaire designed to capture those with high impulsivity. These patients were assessed using the Barratt Impulsiveness Scale, Version 11, and a modified Minnesota Impulse Disorders Interview. Case records and medication schedules were evaluated. Twelve cases of patients with de novo ICDs were found with a range of impulsive behaviors including pathological gambling, kleptomania, compulsive shopping, and hypersexuality. Criminality, suicidality, and marital discord also were featured. These occurred over a wide range of latencies and l-dopa exposures. This group of Australian RLS patients with ICDs display high levels of impulsivity and is the first to use the BIS-11 questionnaire in this setting. Impulse control disorders can occur over a wide range of dopamine agonist therapy types and dose exposures. Impulse control disorder tendencies may persist, despite withdrawal of dopamine agonists. The emergence of ICDs needs careful consideration in light of their potentially devastating financial, social, and marital consequences.

  15. The Utility and Challenges of Using ICD Codes in Child Maltreatment Research: A Review of Existing Literature

    Science.gov (United States)

    Scott, Debbie; Tonmyr, Lil; Fraser, Jenny; Walker, Sue; McKenzie, Kirsten

    2009-01-01

    Objective: The objectives of this article are to explore the extent to which the International Statistical Classification of Diseases and Related Health Problems (ICD) has been used in child abuse research, to describe how the ICD system has been applied, and to assess factors affecting the reliability of ICD coded data in child abuse research.…

  16. Body dysmorphic disorder and olfactory reference disorder: proposals for ICD-11

    Directory of Open Access Journals (Sweden)

    David Veale

    2014-01-01

    Full Text Available The article reviews the historical background and symptoms of body dysmorphic disorder (BDD and olfactory reference disorder, and describes the proposals of the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders related to these categories. This paper examines the possible classification of BDD symptoms in ICD-10. Four different possible diagnoses are found (hypochondriacal disorder, schizotypal disorder, delusional disorder, or other persistent delusional disorder. This has led to significant confusion and lack of clear identification in ICD-10. Olfactory reference disorder can also be classified as a delusional disorder in ICD-10, but there is no diagnosis for non-delusional cases. The Working Group reviewed the classification and diagnostic criteria of BDD in DSM-5, as well as cultural variations of BDD and olfactory reference disorder that include Taijin Kyofusho. The Working Group has proposed the inclusion of both BDD and olfactory reference disorder in ICD-11, and has provided diagnostic guidelines and guidance on differential diagnosis. The Working Group's proposals for ICD-11 related to BDD and olfactory reference disorder are consistent with available global evidence and current understanding of common mechanisms in obsessive-compulsive and related disorders, and resolve considerable confusion inherent in ICD-10. The proposals explicitly recognize cultural factors. They are intended to improve clinical utility related to appropriate identification, treatment, and resource allocation related to these disorders.

  17. The impact of proposed changes to ICD-11 on estimates of PTSD prevalence and comorbidity.

    Science.gov (United States)

    Wisco, Blair E; Miller, Mark W; Wolf, Erika J; Kilpatrick, Dean; Resnick, Heidi S; Badour, Christal L; Marx, Brian P; Keane, Terence M; Rosen, Raymond C; Friedman, Matthew J

    2016-06-30

    The World Health Organization's posttraumatic stress disorder (PTSD) work group has published a proposal for the forthcoming edition of the International Classification of Diseases (ICD-11) that would yield a very different diagnosis relative to DSM-5. This study examined the impact of the proposed ICD-11 changes on PTSD prevalence relative to the ICD-10 and DSM-5 definitions and also evaluated the extent to which these changes would accomplish the stated aim of reducing the comorbidity associated with PTSD. Diagnostic prevalence estimates were compared using a U.S. national community sample and two U.S. Department of Veterans Affairs clinical samples. The ICD-11 definition yielded prevalence estimates 10-30% lower than DSM-5 and 25% and 50% lower than ICD-10 with no reduction in the prevalence of common comorbidities. Findings suggest that by constraining the diagnosis to a narrower set of symptoms, the proposed ICD-11 criteria set would substantially reduce the number of individuals with the disorder. These findings raise doubt about the extent to which the ICD-11 proposal would achieve the aim of reducing comorbidity associated with PTSD and highlight the public health and policy implications of such a redefinition.

  18. Obsessive-compulsive disorder for ICD-11: proposed changes to the diagnostic guidelines and specifiers

    Directory of Open Access Journals (Sweden)

    Helen Blair Simpson

    2014-01-01

    Full Text Available Since the approval of the ICD-10 by the World Health Organization (WHO in 1990, global research on obsessive-compulsive disorder (OCD has expanded dramatically. This article evaluates what changes may be needed to enhance the scientific validity, clinical utility, and global applicability of OCD diagnostic guidelines in preparation for ICD-11. Existing diagnostic guidelines for OCD were compared. Key issues pertaining to clinical description, differential diagnosis, and specifiers were identified and critically reviewed on the basis of the current literature. Specific modifications to ICD guidelines are recommended, including: clarifying the definition of obsessions (i.e., that obsessions can be thoughts, images, or impulses/urges and compulsions (i.e., clarifying that these can be behaviors or mental acts and not calling these “stereotyped”; stating that compulsions are often associated with obsessions; and removing the ICD-10 duration requirement of at least 2 weeks. In addition, a diagnosis of OCD should no longer be excluded if comorbid with Tourette syndrome, schizophrenia, or depressive disorders. Moreover, the ICD-10 specifiers (i.e., predominantly obsessional thoughts, compulsive acts, or mixed should be replaced with a specifier for insight. Based on new research, modifications to the ICD-10 diagnostic guidelines for OCD are recommended for ICD-11.

  19. Evaluation of inpatient clinical documentation readiness for ICD-10-CM.

    Science.gov (United States)

    DeAlmeida, Dilhari R; Watzlaf, Valerie J; Anania-Firouzan, Patti; Salguero, Otto; Rubinstein, Elaine; Abdelhak, Mervat; Parmanto, Bambang

    2014-01-01

    This research study examined the gaps in documentation that occur when coding in ICD-10-CM. More than 4,000 diagnoses from all chapters were coded from 656 electronic documents obtained from a large integrated healthcare facility at the time the study was conducted (2012). After the documents were coded, areas for documentation improvement were identified for chapters that resulted in deficiencies in documentation, and a quick reference guide was developed. The overall absent documentation percentage was 15.4 percent. The 10 chapters with the highest percentage of absent documentation were chapter 7 (Diseases of Eye and Adnexa), with 67.65 percent (p Diseases of Ear and Mastoid Process), with 63.64 percent (p Diseases of the Musculoskeletal System and Connective Tissue), with 46.05 percent (p Diseases of the Genitourinary System), with 40.29 percent (p Diseases of Respiratory System), with 35.52 percent (p Parasitic Diseases), with 32.88 percent (p Diseases of the Skin and Subcutaneous Tissue), with 32.35 percent (p Diseases), with 14.58 percent (p < .001); and chapter 17 (Congenital Malformations, Deformations, and Chromosomal Abnormalities), with 12.50 percent. We addressed the deficient areas in the quick reference guide developed for clinicians and technology vendors. Having complete and accurate documentation would benefit both the clinician and the patient in providing the highest quality of care.

  20. Intracellular fragment of NLRR3 (NLRR3-ICD) stimulates ATRA-dependent neuroblastoma differentiation

    Energy Technology Data Exchange (ETDEWEB)

    Akter, Jesmin [Laboratory of Innovative Cancer Therapeutics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Takatori, Atsushi, E-mail: atakatori@chiba-cc.jp [Laboratory of Cancer Genetics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Islam, Md. Sazzadul [Laboratory of Innovative Cancer Therapeutics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Nakazawa, Atsuko [Department of Pathology, National Center for Child Health and Development, Tokyo (Japan); Ozaki, Toshinori, E-mail: tozaki@chiba-cc.jp [Laboratory of DNA Damage Signaling, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Nagase, Hiroki [Laboratory of Cancer Genetics, Chiba Cancer Center Research Institute, Chiba 260-8717 (Japan); Nakagawara, Akira [Saga Medical Centre, 840-8571 (Japan)

    2014-10-10

    Highlights: • NLRR3 is a membrane protein highly expressed in favorable neuroblastoma. • NLRR3-ICD was produced through proteolytic processing by secretases. • NLRR3-ICD was induced to be translocated into cell nucleus following ATRA exposure. • NLRR3-ICD plays a pivotal role in ATRA-mediated neuroblastoma differentiation. - Abstract: We have previously identified neuronal leucine-rich repeat protein-3 (NLRR3) gene which is preferentially expressed in favorable human neuroblastomas as compared with unfavorable ones. In this study, we have found for the first time that NLRR3 is proteolytically processed by secretases and its intracellular domain (NLRR3-ICD) is then released to translocate into cell nucleus during ATRA-mediated neuroblastoma differentiation. According to our present observations, NLRR3-ICD was induced to accumulate in cell nucleus of neuroblastoma SH-SY5Y cells following ATRA treatment. Since the proteolytic cleavage of NLRR3 was blocked by α- or γ-secretase inhibitor, it is likely that NLRR3-ICD is produced through the secretase-mediated processing of NLRR3. Intriguingly, forced expression of NLRR3-ICD in neuroblastoma SK-N-BE cells significantly suppressed their proliferation as examined by a live-cell imaging system and colony formation assay. Similar results were also obtained in neuroblastoma TGW cells. Furthermore, overexpression of NLRR3-ICD stimulated ATRA-dependent neurite elongation in SK-N-BE cells. Together, our present results strongly suggest that NLRR3-ICD produced by the secretase-mediated proteolytic processing of NLRR3 plays a crucial role in ATRA-mediated neuronal differentiation, and provide a clue to develop a novel therapeutic strategy against aggressive neuroblastomas.

  1. How well do the DSM-5 alcohol use disorder designations map to the ICD-10 disorders?

    Science.gov (United States)

    Hoffmann, Norman G; Kopak, Albert M

    2015-04-01

    The Diagnostic and Statistical Manual of Mental Disorders, 5th edition (DSM-5), and the International Statistical Classification of Diseases and Related Health Problems, 10th edition (ICD-10), both establish diagnostic criteria for alcohol use disorders. The dimensional severity perspective provided by the DSM-5 may overlap in important ways but also may diverge from the categorical harmful use versus dependence designations presented by the ICD-10. It is especially important to consider the convergence of these 2 diagnostic approaches as the DSM is widely used by clinicians, but the U.S. Centers for Medicare and Medicaid Services has recently required that providers bill for services using the ICD-10 designations. Data from 6,871 male and 801 female admissions to a state prison system were used to compare the DSM-5 severity index for alcohol use disorder to the ICD-10 clinical and research formulations for harmful use and dependence. The DSM-5 and the ICD-10 were highly convergent for the most severe alcohol use disorders and also for those who did not receive a diagnosis. Most DSM-5 moderate alcohol use disorder cases were classified as dependence cases under both the clinical and research ICD criteria. In contrast, there was much more variation in the DSM mild cases. These were divided into categories of harmful use or misuse, depending on whether the clinical or research ICD criteria were applied. Results were similar among male and female inmates. The DSM-5 and ICD-10 exhibit a high level of agreement for cases that would not receive a diagnosis as well as the most severe cases. However, there are important distinctions to be made between the 2 approaches for mild and moderate DSM disorders in addition to harmful use/misuse cases in the ICD. The cases influenced by these discrepancies are most likely to be affected by recently implemented service provider billing practices. Copyright © 2015 by the Research Society on Alcoholism.

  2. Diagnostic Concordance between DSM-5 and ICD-10 Cannabis Use Disorders.

    Science.gov (United States)

    Proctor, Steven L; Williams, Daniel C; Kopak, Albert M; Voluse, Andrew C; Connolly, Kevin M; Hoffmann, Norman G

    2016-07-01

    With the recent federal mandate that all U.S. health care settings transition to ICD-10 billing codes, empirical evidence is necessary to determine if the DSM-5 designations map to their respective ICD-10 diagnostic categories/billing codes. The present study examined the concordance between DSM-5 and ICD-10 cannabis use disorder diagnoses. Data were derived from routine clinical assessments of 6871 male and 801 female inmates recently admitted to a state prison system from 2000 to 2003. DSM-5 and ICD-10 diagnostic determinations were made from algorithms corresponding to the respective diagnostic formulations. Past 12-month prevalence rates of cannabis use disorders were comparable across classification systems. The vast majority of inmates with no DSM-5 diagnosis continued to have no diagnosis per the ICD-10, and a similar proportion with a DSM-5 severe diagnosis received an ICD-10 dependence diagnosis. Most of the variation in diagnostic classifications was accounted for by those with a DSM-5 moderate diagnosis in that approximately half of these cases received an ICD-10 dependence diagnosis while the remaining cases received a harmful use diagnosis. Although there appears to be a generally high level of agreement between diagnostic classification systems for those with no diagnosis or those evincing symptoms of a more severe condition, concordance between DSM-5 moderate and ICD-10 dependence diagnoses was poor. Additional research is warranted to determine the appropriateness and implications of the current DSM-5 coding guidelines regarding the assignment of an ICD-10 dependence code for those with a DSM-5 moderate diagnosis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Effect of digital cellular phones on tachyarrhythmia analysis of automated external defibrillators.

    Science.gov (United States)

    Kanz, Karl-Georg; Kay, Mike V; Biberthaler, Peter; Russ, Walter; Lackner, Christian K; Mutschler, Wolf

    2004-04-01

    Emergency services personnel, family members, laypersons or patients often carry and use mobile phones on sites of emergencies. As there are reported effects on implanted pacemakers and cardioverter defibrillators, the influence of digital cellular phones on automated external defibrillators was studied. Twelve automated external defibrillator models were bench tested for their correct decision to or not to advise a shock, while being exposed to electromagnetic interference from a handheld cellular phone with 2 W or a portable cellular phone with 8 W transmitting power. The phones were programmed by a special subscriber identity module card to maximum output power with a carrier frequency of 906.2 MHz. The tests were conducted with a burst frequency of 217 Hz in speech mode and 2-8 Hz in discontinuous transmitting exchange mode. The sensitivity and specificity of electrocardiogram analysis systems were tested, with shockable and non-shockable rhythms provided by an electrocardiogram simulator and on two human subjects with normal sinus rhythm. A total of 8640 tests were recorded, each automated external defibrillator was tested a total of 720 times. The automated external defibrillators demonstrated a sensitivity of 100% and a specificity of 100%, representing a positive likelihood ratio of 8641 and a negative likelihood ratio of 0.000. In this setting all automated external defibrillators analysed correctly even under worst-case testing conditions, and performed excellently without any single failure. In some devices, voice prompts were distorted beyond comprehension, as the coil of the automated external defibrillator speaker received the pulsed signals. Shock advisory systems of automated external defibrillators are not susceptible to electromagnetic interference of 900 MHz cellular phones. Voice prompts, however, could be distorted by the operation of nearby digital mobile phones. During automated external defibrillator training this issue needs to be addressed.

  4. Automated external defibrillators in the Australian fitness industry.

    Science.gov (United States)

    Norton, Kevin I; Norton, Lynda H

    2008-04-01

    Sudden cardiac arrest (SCA) occurs in many thousands of Australians each year. Scientific evidence shows an increased survival rate for individuals who receive electrical defibrillation in the first few minutes after SCA. In the last decade automated (rhythm-detecting) external defibrillators (AEDs) have become available that are portable and affordable. Although still relatively rare, there is still the potential that SCA may occur when a person undertakes physical activity. Consequently, health/fitness centres are increasingly recognised as higher risk sites that may benefit from placement of AEDs. There are no laws in Australia requiring health/fitness centres to install AEDs. However, several international and professional organisations have "strongly encouraged" larger centres to install AEDs. Guidelines and algorithms are presented to help estimate the risk of SCA in fitness centres. Fitness centre placement is particularly important if the clientele is older or has a 'high-risk' profile, for example, clients with cardiovascular, respiratory or metabolic disease. International negligence case law and duty of care principles suggests the standard of care required in health/fitness centres may be increasing. Therefore, it may be prudent to install AEDs in larger centres and those in which higher risk groups are physically active.

  5. Programming implantable cardioverter-defibrillators in primary prevention: higher or later.

    Science.gov (United States)

    Clementy, Nicolas; Pierre, Bertrand; Simeon, Edouard; Lallemand, Bénédicte; Fauchier, Laurent; Babuty, Dominique

    2014-05-01

    Defibrillator shocks, appropriate or not, are associated with significant morbidity, as they decrease quality of life, can be involved in depression and anxiety, and are known to be proarrhythmic. Most recent data have even shown an association between shocks and overall mortality. As opposed to other defibrillator-related complications, the rate of inappropriate and unnecessary shocks can (and should) be decreased with adequate programming. This review focuses on the different programming strategies and tips available to reduce the rate of shocks in primary prevention patients with left ventricular dysfunction implanted with a defibrillator, as well as some of the manufacturers' device specificities.

  6. Defibrillation beliefs of rural nurses: focus group discussions guided by the Theory of Planned Behaviour.

    Science.gov (United States)

    Dwyer, T A; Mosel Williams, L; Mummery, K

    2005-01-01

    The endorsement of the chain of survival concept and early defibrillation has challenged health professionals to reconsider their beliefs about how they respond to in-hospital resuscitation. In the rural context, where 24 hour coverage is not available nurse-initiated defibrillation is expected. Despite literature and policy change in Australia to allow nurses to initiate defibrillation, there is no current research that uses a systemic theoretical approach to investigate the specific beliefs of nurses and their use of defibrillators. The purpose of this study was to elicit a beginning understanding of the defibrillation beliefs of rural nurses. This research used focus groups within the framework of the Theory of Planned Behavior to describe the defibrillation beliefs of rural registered nurses. The sites selected for this study were two acute care hospitals in rural Australia (RRMA Classification). Each of these hospitals was in located 'other rural areas' (RRMA Classification) in separate towns and had 25 and 30 beds. The study sample consisted of 10 females and two males. Focus group questions were designed to elicit salient beliefs within the theoretical framework. Three constructs of behavioral, normative and control beliefs guided the development of the question and analysis of the discussions. In accordance with the authors of the theoretical framework, content analysis was used to analyse the data from the study. Two behavioral beliefs, four control beliefs and four normative belief categories were elicited. Two behavioral beliefs categories emerged from the open-ended question: 'What, if any are the advantages of you being able to use a defibrillator?' Participants were congruent when discussing the advantages of nurses initiating defibrillation. The two categories were 'quicker response times' (15 responses) and 'increased success with resuscitation' (8 responses). Participants were asked to identify any events that might influence their decision to use

  7. Discussion on Bone Cement Implantation Syndrome ICD-10 Coding%骨水泥植入综合征ICD-10编码的探讨

    Institute of Scientific and Technical Information of China (English)

    刘颖

    2016-01-01

    Clinical syndrome is a variety of clinical manifestations characterized diagnosis name caused by different causes of unknown etiology. As an independent disease diagnosis, it brings certain difficulty of ICD coding. In this paper, we take bone cement implantation syndrome for example. We had not been found the corresponding code after looking for the main word "Syndrome", "disease" and "disorder" in ICD-10 book Ⅲ index table. Through referring to the relevant medical information, and timely communicating with the clinician, we had the further understanding for its etiology, pathogenesis, clinical manifestations, etc, stripping external representation and dig the nature of the disease, find out the most main pathogenesis of bone cement implantation syndrome, follow the ICD coding rules, eventually give correct classification of diseases T88.7. This article discussed ICD-10 code process of bone cement implantation syndrome, in order to communicate with peers, and improve the quality of diagnostic codes.%临床综合征是以病因不明或不同病因并存而引起的多种临床表现为特征的诊断名称,作为非独立的疾病诊断,给 ICD 编码的查找工作带来一定难度.本文以骨水泥植入综合征为例,在 ICD-10 卷三索引表中对主导词"综合征"、"病"、"疾患"等查询,均未查到与之对应的编码.通过查阅相关医学资料,并及时与临床医师沟通,对其病因、发病机制、临床表现等方面有了进一步了解,剥去外在表象探索疾病的本质,找出引起骨水泥植入综合征最主要的发病机制,遵循 ICD 编码规则,最终给予正确疾病分类 T88.7.通过对骨水泥植入综合征的 ICD-10 编码过程加以阐述,以期与同行交流,提高疾病诊断编码质量.

  8. The Effect of Compressor-Administered Defibrillation on Peri-shock Pauses in a Simulated Cardiac Arrest Scenario

    Directory of Open Access Journals (Sweden)

    Joshua Glick

    2014-03-01

    Full Text Available Introduction: Coordination of the tasks of performing chest compressions and defibrillation can lead to communication challenges that may prolong time spent off the chest. The purpose of this study was to determine whether defibrillation provided by the provider performing chest compressions led to a decrease in peri-shock pauses as compared to defibrillation administered by a second provider, in a simulated cardiac arrest scenario. Methods: This was a randomized, controlled study measuring pauses in chest compressions for defibrillation in a simulated cardiac arrest model. We approached hospital providers with current CPR certification for participation between July, 2011 and October, 2011. Volunteers were randomized to control (facilitator-administered defibrillation or experimental (compressor-administered defibrillation groups. All participants completed one minute of chest compressions on a mannequin in a shockable rhythm prior to administration of defibrillation. We measured and compared pauses for defibrillation in both groups. Results: Out of 200 total participants, we analyzed data from 197 defibrillations. Compressor-initiated defibrillation resulted in a significantly lower pre-shock hands-off time (0.57 s; 95% CI: 0.47-0.67 compared to facilitator-initiated defibrillation (1.49 s; 95% CI: 1.35-1.64. Furthermore, compressor-initiated defibrillation resulted in a significantly lower peri-shock hands-off time (2.77 s; 95% CI: 2.58-2.95 compared to facilitator-initiated defibrillation (4.25 s; 95% CI: 4.08-4.43. Conclusion: Assigning the responsibility for shock delivery to the provider performing compressions encourages continuous compressions throughout the charging period and decreases total time spent off the chest. However, as this was a simulation-based study, clinical implementation is necessary to further evaluate these potential benefits. [West J Emerg Med. 2014;15(2:246–250.

  9. Changes needed in the classification of anxiety disorders in childhood: Options for ICD-11

    Directory of Open Access Journals (Sweden)

    Stanković Miodrag

    2015-01-01

    Full Text Available Considering the intensive preparation of the 11th revision of the International Classification of Diseases (ICD-11, we discussed the justification of the existing classification of emotional disorders with onset specific to childhood. This paper presents the citations from the ICD-10 (F93 block and the authors’ comments as a critical review of the justification of further existence of emotional disorders with onset specific to childhood as a separate block in ICD-11 classification. We concluded that the block F93 is insufficiently defined and should be completely changed or removed from the ICD-11 classification. Additionally, the specificities of the clinical picture of anxiety disorders in children should be adequately described within the future category of anxiety and phobic disorders by giving an explicit set of instructions for identifying clinical manifestations which vary by age.

  10. Epidemiology, course and outcome of acute polymorphic psychotic disorder: implications for ICD-11

    DEFF Research Database (Denmark)

    Castagnini, Augusto; Foldager, Leslie

    2014-01-01

    Background: The proposed revision of the ICD-10 category of ‘acute and transient psychotic disorders' (ATPDs), subsuming polymorphic, schizophrenic or predominantly delusional syndromes, would restrict their classification to acute polymorphic psychotic disorder, reminiscent of the clinical conce...

  11. Nuclear Ep-ICD expression is a predictor of poor prognosis in "low risk" prostate adenocarcinomas.

    Directory of Open Access Journals (Sweden)

    Jasmeet Assi

    Full Text Available Molecular markers for predicting prostate cancer (PCa that would have poor prognosis are urgently needed for a more personalized treatment for patients. Regulated intramembrane proteolysis of Epithelial cell adhesion molecule results in shedding of the extracellular domain (EpEx and release of its intracellular domain (Ep-ICD which triggers oncogenic signaling and might correlate to tumor aggressiveness. This study aimed to explore the potential of Ep-ICD and EpEx to identify PCa that have poor prognosis.Immunohistochemical analysis of Ep-ICD and EpEx was carried out in normal prostate tissues (n = 100, benign prostate hyperplasia (BPH, n = 83, and prostate cancer (n = 249 using domain specific antibodies. The expression of Ep-ICD and EpEx was correlated with clinico- pathological parameters and disease free survival (DFS.Reduced expression of nuclear Ep-ICD and membrane EpEx was observed in PCa in comparison with BPH and normal prostate tissues (p = 0.006, p < 0.001 respectively. For patients who had PCa with Gleason Score less than 7, preserved nuclear Ep-ICD emerged as the most significant marker in multivariate analysis for prolonged DFS, where these patients did not have recurrence during follow up of up to 12 years (p = 0.001.Reduced expression of nuclear Ep-ICD was associated with shorter disease free survival in patients with a Gleason Score less than 7 and may be useful in identifying patients likely to have aggressive tumors with poor prognosis. Furthermore, nuclear Ep-ICD can differentiate between normal and prostate cancer tissues for ambiguous cases.

  12. Training and support to improve ICD coding quality: A controlled before-and-after impact evaluation

    Directory of Open Access Journals (Sweden)

    Robin Dyers

    2017-06-01

    Full Text Available Background. The proposed National Health Insurance policy for South Africa (SA requires hospitals to maintain high-quality International Statistical Classification of Diseases (ICD codes for patient records. While considerable strides had been made to improve ICD coding coverage by digitising the discharge process in the Western Cape Province, further intervention was required to improve data quality. The aim of this controlled before-and-after study was to evaluate the impact of a clinician training and support initiative to improve ICD coding quality. Objective. To compare ICD coding quality between two central hospitals in the Western Cape before and after the implementation of a training and support initiative for clinicians at one of the sites. Methods. The difference in differences in data quality between the intervention site and the control site was calculated. Multiple logistic regression was also used to determine the odds of data quality improvement after the intervention and to adjust for potential differences between the groups. Results. The intervention had a positive impact of 38.0% on ICD coding completeness over and above changes that occurred at the control site. Relative to the baseline, patient records at the intervention site had a 6.6 (95% confidence interval 3.5 - 16.2 adjusted odds ratio of having a complete set of ICD codes for an admission episode after the introduction of the training and support package. The findings on impact on ICD coding accuracy were not significant. Conclusion. There is sufficient pragmatic evidence that a training and support package will have a considerable positive impact on ICD coding completeness in the SA setting.

  13. Time-resolved study of ICD in Ne dimers using FEL radiation

    Energy Technology Data Exchange (ETDEWEB)

    Schnorr, K., E-mail: kirsten.schnorr@mpi-hd.mpg.de [Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Senftleben, A. [Universität Kassel, 34132 Kassel (Germany); Schmid, G.; Augustin, S.; Kurka, M. [Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Rudenko, A. [J.R. Macdonald Laboratory, Kansas State University, Manhattan, KS 66506 (United States); Foucar, L. [Max-Planck-Institut für medizinische Forschung, 69120 Heidelberg (Germany); Broska, A.; Meyer, K. [Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg (Germany); Anielski, D.; Boll, R. [Deutsches Elektronen-Synchrotron, 22607 Hamburg (Germany); Rolles, D. [J.R. Macdonald Laboratory, Kansas State University, Manhattan, KS 66506 (United States); Kübel, M.; Kling, M.F. [Physics Department, Ludwig-Maximilians-Universität München, 85748 Garching (Germany); Jiang, Y.H. [Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210 (China); Mondal, S.; Tachibana, T.; Ueda, K. [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai 980-8577 (Japan); Marchenko, T.; Simon, M. [Laboratoire de Chimie Physique-Matière et Rayonnement, UPMC and CNRS, 75231 Paris (France); and others

    2015-10-15

    Interatomic Coulombic Decay (ICD) is a relaxation phenomenon, which takes place in weakly bound atomic and molecular systems, typically within a few to hundreds of femtoseconds depending on the system and the particular decay mechanism. The creation of ICD-active states requires the production of highly excited systems, usually populated by innershell ionization or excitation. To this end, XUV and X-ray radiation from synchrotrons was conventionally applied for the majority of experiments due to the desired state-selective ionization of certain sub-shells. The advent of Free-Electron Lasers (FELs) has enabled an entirely new class of experiments, which finally allow to trace ICD directly in the time domain due to the femtosecond pulse duration. Within this paper, the first time-resolved ICD measurement using an XUV-pump–XUV-probe scheme will be discussed in detail. The experiment was performed on neon dimers and ICD was triggered by removing a 2s electron from one of the neon atoms using a 58 eV pulse from the FEL in Hamburg (FLASH). The onset of ICD was probed with a delayed copy of the trigger pulse that further ionized one of the two Ne{sup +} ions emerging after ICD. Thus, the delay-dependent yield of coincident Ne{sup +} + Ne{sup 2+} ion pairs contains the lifetime of the 2s-innershell vacancy decaying via ICD. The result of 150 fs ± 50 fs is in good agreement with theory but only for those calculations that explicitly take nuclear motion into account.

  14. Translating ICD-11 into French using lexical-based approach: a preliminary study.

    Science.gov (United States)

    Merabti, Tayeb; Grosjean, Julien; Rodrigues, Jean-Marie; Darmoni, Stefan Jacques

    2015-01-01

    To translate the 11th edition of the International Classification of Diseases (ICD-11) into French, we proposed a lexical approach using Natural Language Processing techniques. This method relies on the 56 biomedical terminologies and ontologies included in the Cross-lingual Health Multiple Terminologies and Ontologies Portal. From a sample of 336 ICD-11 terms, the algorithm translated 164 (49%) terms into at least one French term each.

  15. Intracellular fragment of NLRR3 (NLRR3-ICD) stimulates ATRA-dependent neuroblastoma differentiation.

    Science.gov (United States)

    Akter, Jesmin; Takatori, Atsushi; Islam, Md Sazzadul; Nakazawa, Atsuko; Ozaki, Toshinori; Nagase, Hiroki; Nakagawara, Akira

    2014-10-10

    We have previously identified neuronal leucine-rich repeat protein-3 (NLRR3) gene which is preferentially expressed in favorable human neuroblastomas as compared with unfavorable ones. In this study, we have found for the first time that NLRR3 is proteolytically processed by secretases and its intracellular domain (NLRR3-ICD) is then released to translocate into cell nucleus during ATRA-mediated neuroblastoma differentiation. According to our present observations, NLRR3-ICD was induced to accumulate in cell nucleus of neuroblastoma SH-SY5Y cells following ATRA treatment. Since the proteolytic cleavage of NLRR3 was blocked by α- or γ-secretase inhibitor, it is likely that NLRR3-ICD is produced through the secretase-mediated processing of NLRR3. Intriguingly, forced expression of NLRR3-ICD in neuroblastoma SK-N-BE cells significantly suppressed their proliferation as examined by a live-cell imaging system and colony formation assay. Similar results were also obtained in neuroblastoma TGW cells. Furthermore, overexpression of NLRR3-ICD stimulated ATRA-dependent neurite elongation in SK-N-BE cells. Together, our present results strongly suggest that NLRR3-ICD produced by the secretase-mediated proteolytic processing of NLRR3 plays a crucial role in ATRA-mediated neuronal differentiation, and provide a clue to develop a novel therapeutic strategy against aggressive neuroblastomas.

  16. Piloting a Collaborative Web-Based System for Testing ICD-11.

    Science.gov (United States)

    Donada, Marc; Kostanjsek, Nenad; Della Mea, Vincenzo; Celik, Can; Jakob, Robert

    2017-01-01

    The 11th revision of the International Classification of Diseases (ICD-11), for the first time in ICD history, deployed web-based collaboration of experts and ICT tools. To ensure that ICD-11 is working well, it needs to be systematically field tested in different settings, across the world. This will be done by means of a number of experiments. In order to support its implementation, a web-based system (ICDfit) has been designed and developed. The present paper illustrates the current prototype of the system and its technical testing. the system has been designed according to WHO requirements, and implemented using PHP and MySQL. Then, a preliminary technical test has been designed and run in January 2016, involving 8 users. They had to carry out double coding, that is, coding case summaries with both ICD-10 and ICD-11, and answering quick questions on the coding difficulty. the 8 users coded 632 cases each, spending an average of 163 seconds per case. While we found an issue in the mechanism used to record coding times, no further issues were found. the proposed system seems to be technically adequate for supporting future ICD-11 testing.

  17. Validity of ICD-9-CM codes for the identification of complications related to central venous catheterization.

    Science.gov (United States)

    Tukey, Melissa H; Borzecki, Ann M; Wiener, Renda Soylemez

    2015-01-01

    Two complications of central venous catheterization (CVC), iatrogenic pneumothorax and central line-associated bloodstream infection (CLABSI), have dedicated International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes. Despite increasing use of ICD-9-CM codes for research and pay-for-performance purposes, their validity for detecting complications of CVC has not been established. Complications of CVCs placed between July 2010 and December 2011 were identified by ICD-9-CM codes in discharge records from a single hospital and compared with those revealed by medical record abstraction. The ICD-9-CM code for iatrogenic pneumothorax had a sensitivity of 66.7%, specificity of 100%, positive predictive value (PPV) of 100%, and negative predictive value (NPV) of 99.5%. The ICD-9-CM codes for CLABSI had a sensitivity of 33.3%, specificity of