Sample records for dedicated pet siemens

  1. Progress on dedicated animal PET

    International Nuclear Information System (INIS)

    Liu Wei

    2002-01-01

    Positron emission tomography, as the leading technology providing molecular imaging of biological processes, is widely used on living laboratory animals. High-resolution dedicated animal PET scanners have been developed. Although the dedicated animal PET faces obstacles and challenges, this advanced technology would play an important role in molecular biomedicine researches, such as diseases study, medicine development, and gene therapy

  2. SIEMENS

    International Nuclear Information System (INIS)

    2001-01-01

    This CD is multimedia presentation of programme safety upgrading of Bohunice V1 NPP. This chapter contains information about Siemens and it participation on reconstruction of Bohunice V1 and V1 NPPs. It consists of next parts: (1) FRAMATOME ANP - worldwide activities of the FRAMATOME are presented; (2) Nuclear power engineering - present activities focus on: Upgrading and Backfitting (Siemens WWER activities since 1971); Electrical instrumentation and control systems; Fuel assemblies and related services; Reactor development and construction of new plants; (3) Safety improvement; (4) Siemens in Slovakia (activities of Siemens in Slovakia during 1993-2000 are presented); (5) More than 150-year history

  3. Effect of filters and reconstruction algorithms on I-124 PET in Siemens Inveon PET scanner

    Science.gov (United States)

    Ram Yu, A.; Kim, Jin Su

    2015-10-01

    Purpose: To assess the effects of filtering and reconstruction on Siemens I-124 PET data. Methods: A Siemens Inveon PET was used. Spatial resolution of I-124 was measured to a transverse offset of 50 mm from the center FBP, 2D ordered subset expectation maximization (OSEM2D), 3D re-projection algorithm (3DRP), and maximum a posteriori (MAP) methods were tested. Non-uniformity (NU), recovery coefficient (RC), and spillover ratio (SOR) parameterized image quality. Mini deluxe phantom data of I-124 was also assessed. Results: Volumetric resolution was 7.3 mm3 from the transverse FOV center when FBP reconstruction algorithms with ramp filter was used. MAP yielded minimal NU with β =1.5. OSEM2D yielded maximal RC. SOR was below 4% for FBP with ramp, Hamming, Hanning, or Shepp-Logan filters. Based on the mini deluxe phantom results, an FBP with Hanning or Parzen filters, or a 3DRP with Hanning filter yielded feasible I-124 PET data.Conclusions: Reconstruction algorithms and filters were compared. FBP with Hanning or Parzen filters, or 3DRP with Hanning filter yielded feasible data for quantifying I-124 PET.

  4. The continual innovation of commercial PET/CT solutions in nuclear cardiology: Siemens Healthineers.

    Science.gov (United States)

    Bendriem, Bernard; Reed, Jessie; McCullough, Kathryn; Khan, Mohammad Raza; Smith, Anne M; Thomas, Damita; Long, Misty

    2018-04-10

    Cardiac PET/CT is an evolving, non-invasive imaging modality that impacts patient management in many clinical scenarios. Beyond offering the capability to assess myocardial perfusion, inflammatory cardiac pathologies, and myocardial viability, cardiac PET/CT also allows for the non-invasive quantitative assessment of myocardial blood flow (MBF) and myocardial flow reserve (MFR). Recognizing the need for an enhanced comprehension of coronary physiology, Siemens Healthineers implemented a sophisticated solution for the calculation of MBF and MFR in 2009. As a result, each aspect of their innovative scanner and image-processing technology seamlessly integrates into an efficient, easy-to-use workflow for everyday clinical use that maximizes the number of patients who potentially benefit from this imaging modality.

  5. Quantitative comparison of PET performance—Siemens Biograph mCT and mMR

    Energy Technology Data Exchange (ETDEWEB)

    Karlberg, Anna M.; Sæther, Oddbjørn [Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Olav Kyrres gt 17, 7006 Trondheim (Norway); Eikenes, Live [Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Postbox 8905, 7491 Trondheim (Norway); Goa, Pål Erik [Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Olav Kyrres gt 17, 7006 Trondheim (Norway); Department of Physics, Norwegian University of Science and Technology, Trondheim (Norway)

    2016-02-25

    Integrated clinical whole-body PET/MR systems were introduced in 2010. In order to bring this technology into clinical usage, it is of great importance to compare the performance with the well-established PET/CT. The aim of this study was to evaluate PET performance, with focus on image quality, on Siemens Biograph mMR (PET/MR) and Siemens Biograph mCT (PET/CT). A direct quantitative comparison of the performance characteristics between the mMR and mCT system was performed according to National Electrical Manufacturers Association (NEMA) NU 2-2007 protocol. Spatial resolution, sensitivity, count rate and image quality were evaluated. The evaluation was supplemented with additional standardized uptake value (SUV) measurements. The spatial resolution was similar for the two systems. Average sensitivity was higher for the mMR (13.3 kcps/MBq) compared to the mCT system (10.0 kcps/MBq). Peak noise equivalent count rate (NECR) was slightly higher for the mMR (196 kcps @ 24.4 kBq/mL) compared to the mCT (186 kcps @ 30.1 kBq/mL). Scatter fractions in the clinical activity concentration range yielded lower values for the mCT (34.9 %) compared to those for the mMR (37.0 %). Best image quality of the systems resulted in approximately the same mean hot sphere contrast and a difference of 19 percentage points (pp) in mean cold contrast, in favour of the mCT. In general, point spread function (PSF) increased hot contrast and time of flight (TOF) increased both hot and cold contrast. Highest hot contrast for the smallest sphere (10 mm) was achieved with the combination of TOF and PSF on the mCT. Lung residual error was higher for the mMR (22 %) than that for the mCT (17 %), with no effect of PSF. With TOF, lung residual error was reduced to 8 % (mCT). SUV was accurate for both systems, but PSF caused overestimations for the 13-, 17- and 22-mm spheres. Both systems proved good performance characteristics, and the PET image quality of the mMR was close to that of the m

  6. A PET imaging system dedicated to mammography

    CERN Document Server

    Varela, J

    2007-01-01

    The imaging system Clear-PEM for positron emission mammography, under development within the framework of the Crystal Clear Collaboration at CERN, is presented. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes (APD) and readout by a fast low-noise electronic system. A dedicated digital trigger and data acquisition system is used for on-line selection of coincidence events with high efficiency, large bandwidth and negligible dead-time. The detector module performance was characterized in detail.

  7. Ultra fast, accurate PET image reconstruction for the Siemens hybrid MR/BrainPET scanner using raw LOR data

    International Nuclear Information System (INIS)

    Scheins, Juergen; Lerche, Christoph; Shah, Jon

    2015-01-01

    Fast PET image reconstruction algorithms usually use a Line-of-Response (LOR) preprocessing step where the detected raw LOR data are interpolated either to evenly spaced sinogram projection bins or alternatively to a generic projection space as for example proposed by the PET Reconstruction Software Toolkit (PRESTO) [1]. In this way, speed-optimised, versatile geometrical projectors can be implemented for iterative image reconstruction independent of the underlying scanner geometry. However, all strategies of projection data interpolation unavoidably lead to a loss of original information and result in some degradation of image quality. Here, direct LOR reconstructions overcome this evident drawback at cost of a massively enhanced computational burden. Therefore, computational optimisation techniques are essential to make such demanding approaches attractive and economical for widespread usage in the clinical environment. In this paper, we demonstrate for the Siemens Hybrid MR/BrainPET with 240 million physical LORs that a very fast quantitative direct LOR reconstruction can be realized using a modified version of PRESTO. Now, PRESTO is also capable to directly use sets of symmetric physical LORs instead of interpolating LORs to a generic projection space. Exploiting basic scanner symmetries together with the technique of Single Instruction Multipe Data (SIMD) and Simultaneous Multi-Threading (SMT) results in an overall calculation time of 2-3 minutes per frame on a single multi-core machine, i.e. neither requiring a cluster of mutliple machines nor Graphics Processing Units (GPUs).

  8. Ultra fast, accurate PET image reconstruction for the Siemens hybrid MR/BrainPET scanner using raw LOR data

    Energy Technology Data Exchange (ETDEWEB)

    Scheins, Juergen; Lerche, Christoph; Shah, Jon [Forschungszentrum Jülich GmbH, Jülich (Germany)

    2015-05-18

    Fast PET image reconstruction algorithms usually use a Line-of-Response (LOR) preprocessing step where the detected raw LOR data are interpolated either to evenly spaced sinogram projection bins or alternatively to a generic projection space as for example proposed by the PET Reconstruction Software Toolkit (PRESTO) [1]. In this way, speed-optimised, versatile geometrical projectors can be implemented for iterative image reconstruction independent of the underlying scanner geometry. However, all strategies of projection data interpolation unavoidably lead to a loss of original information and result in some degradation of image quality. Here, direct LOR reconstructions overcome this evident drawback at cost of a massively enhanced computational burden. Therefore, computational optimisation techniques are essential to make such demanding approaches attractive and economical for widespread usage in the clinical environment. In this paper, we demonstrate for the Siemens Hybrid MR/BrainPET with 240 million physical LORs that a very fast quantitative direct LOR reconstruction can be realized using a modified version of PRESTO. Now, PRESTO is also capable to directly use sets of symmetric physical LORs instead of interpolating LORs to a generic projection space. Exploiting basic scanner symmetries together with the technique of Single Instruction Multipe Data (SIMD) and Simultaneous Multi-Threading (SMT) results in an overall calculation time of 2-3 minutes per frame on a single multi-core machine, i.e. neither requiring a cluster of mutliple machines nor Graphics Processing Units (GPUs).

  9. Performance evaluation of a high resolution dedicated breast PET scanner

    Energy Technology Data Exchange (ETDEWEB)

    García Hernández, Trinitat, E-mail: mtrinitat@eresa.com; Vicedo González, Aurora; Brualla González, Luis; Granero Cabañero, Domingo [Department of Medical Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Ferrer Rebolleda, Jose; Sánchez Jurado, Raúl; Puig Cozar Santiago, Maria del [Department of Nuclear Medicine, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Roselló Ferrando, Joan [Department of Medical Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Department of Physiology, University of Valencia, Valencia 46010 (Spain)

    2016-05-15

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ({sup 18}F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good

  10. Performance evaluation of a high resolution dedicated breast PET scanner

    International Nuclear Information System (INIS)

    García Hernández, Trinitat; Vicedo González, Aurora; Brualla González, Luis; Granero Cabañero, Domingo; Ferrer Rebolleda, Jose; Sánchez Jurado, Raúl; Puig Cozar Santiago, Maria del; Roselló Ferrando, Joan

    2016-01-01

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ("1"8F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good performance

  11. Molecular Imaging in Breast Cancer: From Whole-Body PET/CT to Dedicated Breast PET

    Directory of Open Access Journals (Sweden)

    B. B. Koolen

    2012-01-01

    Full Text Available Positron emission tomography (PET, with or without integrated computed tomography (CT, using 18F-fluorodeoxyglucose (FDG is based on the principle of elevated glucose metabolism in malignant tumors, and its use in breast cancer patients is frequently being investigated. It has been shown useful for classification, staging, and response monitoring, both in primary and recurrent disease. However, because of the partial volume effect and limited resolution of most whole-body PET scanners, sensitivity for the visualization of small tumors is generally low. To improve the detection and quantification of primary breast tumors with FDG PET, several dedicated breast PET devices have been developed. In this nonsystematic review, we shortly summarize the value of whole-body PET/CT in breast cancer and provide an overview of currently available dedicated breast PETs.

  12. Design and evaluation of the MAMMI dedicated breast PET

    International Nuclear Information System (INIS)

    Moliner, L.; González, A. J.; Soriano, A.; Sánchez, F.; Correcher, C.; Orero, A.; Carles, M.; Vidal, L. F.; Barberá, J.; Caballero, L.; Seimetz, M.; Vázquez, C.; Benlloch, J. M.

    2012-01-01

    Purpose: A breast dedicated positron emission tomography (PET) scanner has been developed based on monolithic LYSO crystals coupled to position sensitive photomultiplier tubes (PSPMTs). In this study, we describe the design of the PET system and report on its performance evaluation. Methods: MAMMI is a breast PET scanner based on monolithic LYSO crystals. It consists of 12 compact modules with a transaxial field of view (FOV) of 170 mm in diameter and 40 mm axial FOV that translates to cover up to 170 mm. The patient lies down in a prone position that facilitates maximum breast elongation. Quantitative performance analysis of the calculated method for the attenuation correction specifically developed for MAMMI, and based on PET image segmentation, has also been conducted in this evaluation. In order to fully determine the MAMMI prototype's performance, we have adapted the measurements suggested for National Electrical Manufacturers Association (NEMA) NU 2-2007 and NU 4-2008 protocol tests, as they are defined for whole-body and small animal PET scanners, respectively. Results: Spatial resolutions of 1.6, 1.8, and 1.9 mm were measured in the axial, radial, and tangential directions, respectively. A scatter fraction of 20.8% was obtained and the maximum NEC was determined to be 25 kcps at 44 MBq. The average sensitivity of the system was observed to be 1% for an energy window of (250 keV–750 keV) and a maximum absolute sensitivity of 1.8% was measured at the FOV center. Conclusions: The overall performance of the MAMMI reported on this evaluation quantifies its ability to produce high quality PET images. Spatial resolution values below 3 mm were measured in most of the FOV. Only the radial component of spatial resolution exceeds the 3 mm at radial positions larger than 60 mm. This study emphasizes the need for standardized testing methodologies for dedicated breast PET systems similar to NEMA standards for whole-body and small animal PET scanners.

  13. A dedicated tool for PET scanner simulations using FLUKA

    International Nuclear Information System (INIS)

    Ortega, P.G.; Boehlen, T.T.; Cerutti, F.; Chin, M.P.W.; Ferrari, A.; Mancini, C.; Vlachoudis, V.; Mairani, A.; Sala, Paola R.

    2013-06-01

    Positron emission tomography (PET) is a well-established medical imaging technique. It is based on the detection of pairs of annihilation gamma rays from a beta+-emitting radionuclide, usually inoculated in the body via a biologically active molecule. Apart from its wide-spread use for clinical diagnosis, new applications are proposed. This includes notably the usage of PET for treatment monitoring of radiation therapy with protons and ions. PET is currently the only available technique for non-invasive monitoring of ion beam dose delivery, which was tested in several clinical pilot studies. For hadrontherapy, the distribution of positron emitters, produced by the ion beam, can be analyzed to verify the correct treatment delivery. The adaptation of previous PET scanners to new environments and the necessity of more precise diagnostics by better image quality triggered the development of new PET scanner designs. The use of Monte Carlo (MC) codes is essential in the early stages of the scanner design to simulate the transport of particles and nuclear interactions from therapeutic ion beams or radioisotopes and to predict radiation fields in tissues and radiation emerging from the patient. In particular, range verification using PET is based on the comparison of detected and simulated activity distributions. The accuracy of the MC code for the relevant physics processes is obviously essential for such applications. In this work we present new developments of the physics models with importance for PET monitoring and integrated tools for PET scanner simulations for FLUKA, a fully-integrated MC particle-transport code, which is widely used for an extended range of applications (accelerator shielding, detector and target design, calorimetry, activation, dosimetry, medical physics, radiobiology, ...). The developed tools include a PET scanner geometry builder and a dedicated scoring routine for coincident event determination. The geometry builder allows the efficient

  14. [F-18]FDG imaging of head and neck tumors: comparison of hybrid PET, dedicated PET and CT

    International Nuclear Information System (INIS)

    Dresel, S.; Brinkbaeumer, K.; Schmid, R.; Poepperl, G.; Hahn, K.; Szeimies, U.

    2001-01-01

    Aim: Aim of the study was to evaluate [F-18]FDG imaging of head and neck tumors using a Hybrid-PET device of the 2nd or 3rd generation. Examinations were compared to dedicated PET and Spiral-CT. Methods: 54 patients suffering from head and neck tumors were examined using dedicated PET and Hybrid-PET after injection of 185-350 MBq [F-18]FDG. Examinations were carried out on the dedicated PET first followed by a scan on the Hybrid-PET. Dedicated PET was acquired in 3D mode, Hybrid-PET was performed in list mode using an axial filter. Reconstruction of data was performed iteratively on both, dedicated PET and Hybrid-PET. All patients received a CT scan in multislice technique. All finding have been verified by the goldstandard histology or in case of negative histology by follow up. Results: Using dedicated PET the primary or recurrent lesion was correctly diagnosed in 47/48 patients, using Hybrid-PET in 46/48 patients and using CT in 25/48 patients. Metastatic disease in cervical lymph nodes was diagnosed in 17/18 patients with dedicated PET, in 16/18 patients with Hybrid-PET and in 15/18 with CT. False positive results with regard to lymph node metastasis were seen with one patient for dedicated PET and Hybrid-PET, respectively, and with 18 patients for CT. In a total of 11 patients unknown metastastic lesions were seen with dedicated PET and with Hybrid-PET elsewhere in the body. Additional malignant disease other than the head and neck tumor was found in 4 patients. Conclusion: Using Hybrid-PET for [F-18]FDG imaging reveals a loss of sensitivity and specificity of about 1-5% as compared to dedicated PET in head and neck tumors. [F-18]FDG PET with both, dedicated PET and Hybrid-PET is superior to CT in the diagnosis of primary or recurrent lesions as well as in the assessment of lymph node involvement. (orig.) [de

  15. Dedicated brain PET system of PET/MR for brain research

    International Nuclear Information System (INIS)

    Cheng, Li; Liu, Yaqiang; Ma, Tianyu; Wang, Shi; Wei, Qingyang; Xu, Tianpeng

    2015-01-01

    This work is to replace PET ring in human brain PET/MR system with a dedicated wearable PET insert, aimed at improving both patient feasibility and system performance for brain imaging. The designed PET/MR system includes two parts: the inside parts, including a radio frequency (RF) coil and PET ring, are mounted on patient’s head, and the outside part, a MR imager, is dependent of patient. The RF coil is the innermost layer, surrounded by an outer PET-ring layer. They are supported by a MRcompatible structure. And both RF coil and PET detectors are placed inside a standard clinical 3-T MR imager. From the design of the system we can infer that some advantages can be achieved. First, high sensitivity will be achieved with the same amount crystals as the PET ring is more close to region-of-interest area, at a reduced cost. Second, by using a 2-layer depth of interaction (DOI) detector, the parallax effect can be minimized. The resolution will benefit from short positron range caused by magnetic field and smaller ring diameter will also reduce the effect of non-collinearity. Thirdly, as the PET ring is mounted on head, impact of patient motion will be reduced.

  16. Dedicated brain PET system of PET/MR for brain research

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Li; Liu, Yaqiang; Ma, Tianyu; Wang, Shi; Wei, Qingyang; Xu, Tianpeng [Institute of Medical Physics, Department of Engineering Physics, Tsinghua University, Beijing (China)

    2015-05-18

    This work is to replace PET ring in human brain PET/MR system with a dedicated wearable PET insert, aimed at improving both patient feasibility and system performance for brain imaging. The designed PET/MR system includes two parts: the inside parts, including a radio frequency (RF) coil and PET ring, are mounted on patient’s head, and the outside part, a MR imager, is dependent of patient. The RF coil is the innermost layer, surrounded by an outer PET-ring layer. They are supported by a MRcompatible structure. And both RF coil and PET detectors are placed inside a standard clinical 3-T MR imager. From the design of the system we can infer that some advantages can be achieved. First, high sensitivity will be achieved with the same amount crystals as the PET ring is more close to region-of-interest area, at a reduced cost. Second, by using a 2-layer depth of interaction (DOI) detector, the parallax effect can be minimized. The resolution will benefit from short positron range caused by magnetic field and smaller ring diameter will also reduce the effect of non-collinearity. Thirdly, as the PET ring is mounted on head, impact of patient motion will be reduced.

  17. Cross calibration of the Siemens mMR: easily acquired accurate PET phantom measurements, long term stability and reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Sune H [Rigshospitalet, University of Copenhagen, Copenhagen (Denmark); Jakoby, Bjorn [University of Surrey, Guildford (United Kingdom); Hansen, Adam Espe; Svalling, Susanne; Klausen, Thomas L [Rigshospitalet, University of Copenhagen, Copenhagen (Denmark)

    2015-05-18

    We present a quick and easy method to perform quantitatively accurate PET scans of typical water-filled PET plastic shell phantoms on the Siemens mMR PET/MR scanner. We perform regular cross calibrations (Xcals) of our PET scanners, including the Siemens mMR PET/MR, with a Siemens mCT water phantom. We evaluate the mMR cross calibration stability over a 3-year period. Recently, the mMR software (VB20P) offered the option of using predefined μ-maps. We evaluated this option by using either the predefined μ-map of the long mMR water phantom or a system-integrated user defined CT-based μ-map of the mCT water phantom used for Xcal. On 54 cross calibrations that were acquired over 3 years, the mMR on average underestimated the concentration by 16% due to the use of MR-based μ-maps. The mMR produced the narrowest range and lowest standard deviation of the Xcal ratios, implying it and is the most stable of the 6 scanners included in this study over a 3 year period. With correctly segmented μ-maps, the mMR produced Xcal ratios of 1.00-1.02, well within the acceptance range [0.95-1.05]. Measuring the concentration in a centrally placed cylindrical VOI allows for some robustness against misregistration of the μ-maps but it should be no more than a few millimeters in the x-y plane, while the tolerance is larger on the z-axis (when, as always with PET, keeping clear of the axial edges of the FOV). The mMR is the most stable scanner in this study and the mean underestimation is no longer an issue with the easily accessible μ-map, which in all 7 tests resulted in correct Xcal ratios. We will share the user defined μ-map of the mCT phantom and the protocol with interested mMR users.

  18. Cross calibration of the Siemens mMR: easily acquired accurate PET phantom measurements, long term stability and reproducibility

    International Nuclear Information System (INIS)

    Keller, Sune H; Jakoby, Bjorn; Hansen, Adam Espe; Svalling, Susanne; Klausen, Thomas L

    2015-01-01

    We present a quick and easy method to perform quantitatively accurate PET scans of typical water-filled PET plastic shell phantoms on the Siemens mMR PET/MR scanner. We perform regular cross calibrations (Xcals) of our PET scanners, including the Siemens mMR PET/MR, with a Siemens mCT water phantom. We evaluate the mMR cross calibration stability over a 3-year period. Recently, the mMR software (VB20P) offered the option of using predefined μ-maps. We evaluated this option by using either the predefined μ-map of the long mMR water phantom or a system-integrated user defined CT-based μ-map of the mCT water phantom used for Xcal. On 54 cross calibrations that were acquired over 3 years, the mMR on average underestimated the concentration by 16% due to the use of MR-based μ-maps. The mMR produced the narrowest range and lowest standard deviation of the Xcal ratios, implying it and is the most stable of the 6 scanners included in this study over a 3 year period. With correctly segmented μ-maps, the mMR produced Xcal ratios of 1.00-1.02, well within the acceptance range [0.95-1.05]. Measuring the concentration in a centrally placed cylindrical VOI allows for some robustness against misregistration of the μ-maps but it should be no more than a few millimeters in the x-y plane, while the tolerance is larger on the z-axis (when, as always with PET, keeping clear of the axial edges of the FOV). The mMR is the most stable scanner in this study and the mean underestimation is no longer an issue with the easily accessible μ-map, which in all 7 tests resulted in correct Xcal ratios. We will share the user defined μ-map of the mCT phantom and the protocol with interested mMR users.

  19. Performance measurement of PSF modeling reconstruction (True X) on Siemens Biograph TruePoint TrueV PET/CT.

    Science.gov (United States)

    Lee, Young Sub; Kim, Jin Su; Kim, Kyeong Min; Kang, Joo Hyun; Lim, Sang Moo; Kim, Hee-Joung

    2014-05-01

    The Siemens Biograph TruePoint TrueV (B-TPTV) positron emission tomography (PET) scanner performs 3D PET reconstruction using a system matrix with point spread function (PSF) modeling (called the True X reconstruction). PET resolution was dramatically improved with the True X method. In this study, we assessed the spatial resolution and image quality on a B-TPTV PET scanner. In addition, we assessed the feasibility of animal imaging with a B-TPTV PET and compared it with a microPET R4 scanner. Spatial resolution was measured at center and at 8 cm offset from the center in transverse plane with warm background activity. True X, ordered subset expectation maximization (OSEM) without PSF modeling, and filtered back-projection (FBP) reconstruction methods were used. Percent contrast (% contrast) and percent background variability (% BV) were assessed according to NEMA NU2-2007. The recovery coefficient (RC), non-uniformity, spill-over ratio (SOR), and PET imaging of the Micro Deluxe Phantom were assessed to compare image quality of B-TPTV PET with that of the microPET R4. When True X reconstruction was used, spatial resolution was RC with True X reconstruction was higher than that with the FBP method and the OSEM without PSF modeling method on the microPET R4. The non-uniformity with True X reconstruction was higher than that with FBP and OSEM without PSF modeling on microPET R4. SOR with True X reconstruction was better than that with FBP or OSEM without PSF modeling on the microPET R4. This study assessed the performance of the True X reconstruction. Spatial resolution with True X reconstruction was improved by 45 % and its % contrast was significantly improved compared to those with the conventional OSEM without PSF modeling reconstruction algorithm. The noise level was higher than that with the other reconstruction algorithm. Therefore, True X reconstruction should be used with caution when quantifying PET data.

  20. Comparison of Imaging Characteristics of 124I PET for Determination of Optimal Energy Window on the Siemens Inveon PET

    Directory of Open Access Journals (Sweden)

    A Ram Yu

    2016-01-01

    Full Text Available Purpose.124I has a half-life of 4.2 days, which makes it suitable for imaging over several days over its uptake and washout phases. However, it has a low positron branching ratio (23%, because of prompt gamma coincidence due to high-energy γ-photons (602 to 1,691 keV, which are emitted in cascade with positrons. Methods. In this study, we investigated the optimal PET energy window for 124I PET based on image characteristics of reconstructed PET. Image characteristics such as nonuniformities, recovery coefficients (RCs, and the spillover ratios (SORs of 124I were measured as described in NEMA NU 4-2008 standards. Results. The maximum and minimum prompt gamma coincidence fraction (PGF were 33% and 2% in 350~800 and 400~590 keV, respectively. The difference between best and worst uniformity in the various energy windows was less than 1%. The lowest SORs of 124I were obtained at 350~750 keV in nonradioactive water compartment. Conclusion. Optimal energy window should be determined based on image characteristics. Our developed correction method would be useful for the correction of high-energy prompt gamma photon in 124I PET. In terms of the image quality of 124I PET, our findings indicate that an energy window of 350~750 keV would be optimal.

  1. Molecular imaging of small animals with dedicated PET tomographs

    International Nuclear Information System (INIS)

    Chatziioannou, A.F.

    2002-01-01

    Biological discovery has moved at an accelerated pace in recent years, with a considerable focus on the transition from in vitro to in vivo models. As a result, there has been a significant increase in the need to adapt clinical imaging methods, as well as for novel imaging technologies for biological research. Positron emission tomography (PET) is a clinical imaging modality that permits the use of positron-labeled molecular imaging probes for non-invasive assays of biochemical processes. The imaging procedure can be repeatedly performed before and after interventions, thereby allowing each animal to be used as its own control. Positron-labeled compounds that target a range of molecular targets have been and continue to be synthesized, with examples of biological processes ranging from receptors and synthesis of transmitters in cell communication, to metabolic processes and gene expression. In animal research, PET has been used extensively in the past for studies of non-human primates and other larger animals. New detector technology has improved spatial resolution, and has made possible PET scanning for the study of the most important modern molecular biology model, the laboratory mouse. This paper presents the challenges facing PET technology as applied to small animal imaging, provides a historical overview of the development of small animal PET systems, and discusses the current state of the art in small animal PET technology. (orig.)

  2. ClearPEM: prototype PET device dedicated to breast imaging

    CERN Multimedia

    Joao Varela

    2009-01-01

    Clinical trials have begun in Portugal on a new breast imaging system (ClearPEM) using positron emission tomography (PET). The system, developed by a Portuguese consortium in collaboration with CERN and laboratories participating in the Crystal Clear collaboration, will detect even the smallest tumours and thus help avoid unnecessary biopsies.

  3. Gamma-camera 18F-FDG PET in diagnosis and staging of patients presenting with suspected lung cancer and comparison with dedicated PET

    DEFF Research Database (Denmark)

    Oturai, Peter S; Mortensen, Jann; Enevoldsen, Henriette

    2004-01-01

    It is not clear whether high-quality coincidence gamma-PET (gPET) cameras can provide clinical data comparable with data obtained with dedicated PET (dPET) cameras in the primary diagnostic work-up of patients with suspected lung cancer. This study focuses on 2 main issues: direct comparison...

  4. Clear-PEM, a dedicated PET camera for mammography

    CERN Document Server

    Lecoq, P

    2002-01-01

    Preliminary results suggest that Positron Emission Mammography (PEM) can offer a noninvasive method for the diagnosis of breast cancer. Metabolic images from PEM contain unique information not available from conventional morphologic imaging techniques and aid in expeditiously establishing the diagnosis of cancer. A dedicated machine seems to offer better perspectives in terms of position resolution and sensitivity. This paper describes the concept of Clear-PEM, the system presently developed by the Crystal Clear Collaboration at CERN for an evaluation of this approach. This device is based on new crystals introduced by the Crystal Clear as well as on modern data acquisition techniques developed for the large experiments in high energy physics experiments.

  5. Dedication

    OpenAIRE

    2013-01-01

    This work is dedicated, to my mom, Bridget, and my dad, (the late) Daniel Enwerem, who taught me to respect people but not fear them; and to those who are engaged or have been victims in the struggle for an egalitarian society in Nigeria.

  6. Cross-calibration of the Siemens mMR

    DEFF Research Database (Denmark)

    Keller, Sune H; Jakoby, Björn; Svalling, Susanne

    2016-01-01

    BACKGROUND: We present a quick and easy method to perform quantitatively accurate PET scans of typical water-filled PET plastic shell phantoms on the Siemens Biograph mMR PET/MR system. We perform regular cross-calibrations (Xcal) of our PET systems, including the PET/MR, using a Siemens mCT water...

  7. Evaluation of a video-based head motion tracking system for dedicated brain PET

    Science.gov (United States)

    Anishchenko, S.; Beylin, D.; Stepanov, P.; Stepanov, A.; Weinberg, I. N.; Schaeffer, S.; Zavarzin, V.; Shaposhnikov, D.; Smith, M. F.

    2015-03-01

    Unintentional head motion during Positron Emission Tomography (PET) data acquisition can degrade PET image quality and lead to artifacts. Poor patient compliance, head tremor, and coughing are examples of movement sources. Head motion due to patient non-compliance can be an issue with the rise of amyloid brain PET in dementia patients. To preserve PET image resolution and quantitative accuracy, head motion can be tracked and corrected in the image reconstruction algorithm. While fiducial markers can be used, a contactless approach is preferable. A video-based head motion tracking system for a dedicated portable brain PET scanner was developed. Four wide-angle cameras organized in two stereo pairs are used for capturing video of the patient's head during the PET data acquisition. Facial points are automatically tracked and used to determine the six degree of freedom head pose as a function of time. The presented work evaluated the newly designed tracking system using a head phantom and a moving American College of Radiology (ACR) phantom. The mean video-tracking error was 0.99±0.90 mm relative to the magnetic tracking device used as ground truth. Qualitative evaluation with the ACR phantom shows the advantage of the motion tracking application. The developed system is able to perform tracking with accuracy close to millimeter and can help to preserve resolution of brain PET images in presence of movements.

  8. PET/CT and dedicated PET in breast cancer: Implications for classification, staging, and response monitoring

    NARCIS (Netherlands)

    Koolen, B.B.

    2013-01-01

    De PET-CT, een scan die gebruik maakt van radioactiviteit om tumoren in beeld te brengen, is een zinvol instrument voor beeldvorming van patiënten met borstkanker, met name van patiënten met een tumor groter dan drie centimeter of tumor-positieve lymfeklieren. De PET-CT is vooral van waarde voor de

  9. A dedicated breast-PET/CT scanner: Evaluation of basic performance characteristics.

    Science.gov (United States)

    Raylman, Raymond R; Van Kampen, Will; Stolin, Alexander V; Gong, Wenbo; Jaliparthi, Gangadhar; Martone, Peter F; Smith, Mark F; Sarment, David; Clinthorne, Neal H; Perna, Mark

    2018-04-01

    Application of advanced imaging techniques, such as PET and x ray CT, can potentially improve detection of breast cancer. Unfortunately, both modalities have challenges in the detection of some lesions. The combination of the two techniques, however, could potentially lead to an overall improvement in diagnostic breast imaging. The purpose of this investigation is to test the basic performance of a new dedicated breast-PET/CT. The PET component consists of a rotating pair of detectors. Its performance was evaluated using the NEMA NU4-2008 protocols. The CT component utilizes a pulsed x ray source and flat panel detector mounted on the same gantry as the PET scanner. Its performance was assessed using specialized phantoms. The radiation dose to a breast during CT imaging was explored by the measurement of free-in-air kerma and air kerma measured at the center of a 16 cm-diameter PMMA cylinder. Finally, the combined capabilities of the system were demonstrated by imaging of a micro-hot-rod phantom. Overall, performance of the PET component is comparable to many pre-clinical and other dedicated breast-PET scanners. Its spatial resolution is 2.2 mm, 5 mm from the center of the scanner using images created with the single-sliced-filtered-backprojection algorithm. Peak NECR is 24.6 kcps; peak sensitivity is 1.36%; the scatter fraction is 27%. Spatial resolution of the CT scanner is 1.1 lp/mm at 10% MTF. The free-in-air kerma is 2.33 mGy, while the PMMA-air kerma is 1.24 mGy. Finally, combined imaging of a micro-hot-rod phantom illustrated the potential utility of the dual-modality images produced by the system. The basic performance characteristics of a new dedicated breast-PET/CT scanner are good, demonstrating that its performance is similar to current dedicated PET and CT scanners. The potential value of this system is the capability to produce combined duality-modality images that could improve detection of breast disease. The next stage in development of this system

  10. Study of the personal radiation dose received by nuclear medicine technologists working in a dedicated PET centre

    International Nuclear Information System (INIS)

    Robinson, C.N.; Wallace, A.B.; Young, A.B.; Ibbetson, V.J.

    2005-01-01

    The use of dedicated PET scanners is becoming more widespread throughout Australia and the world. PET imaging utilises short-lived (-108 min), high-energy (511 keV) gamma-ray emitters, that could result in a high radiation dose being received by staff. As part of a larger staff and area monitoring project, this paper discusses the personal dose equivalent, H p (10), received by PET staff working in a dedicated PET centre. The typical H (10) received by staff was approximately 31 μSv. The average daily administered activity to patients at Austin Health was 1280 MBq

  11. 18F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters.

    Science.gov (United States)

    Mhlanga, Joyce C; Carrino, John A; Lodge, Martin; Wang, Hao; Wahl, Richard L

    2014-12-01

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with (18)F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological (18)F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p = 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted.

  12. 18F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters

    International Nuclear Information System (INIS)

    Mhlanga, Joyce C.; Lodge, Martin; Carrino, John A.; Wang, Hao; Wahl, Richard L.

    2014-01-01

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with 18 F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological 18 F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p= 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted. (orig.)

  13. Clinical evaluation of 2D versus 3D whole-body PET image quality using a dedicated BGO PET scanner

    International Nuclear Information System (INIS)

    Visvikis, D.; Griffiths, D.; Costa, D.C.; Bomanji, J.; Ell, P.J.

    2005-01-01

    Three-dimensional positron emission tomography (3D PET) results in higher system sensitivity, with an associated increase in the detection of scatter and random coincidences. The objective of this work was to compare, from a clinical perspective, 3D and two-dimensional (2D) acquisitions in terms of whole-body (WB) PET image quality with a dedicated BGO PET system. 2D and 3D WB emission acquisitions were carried out in 70 patients. Variable acquisition parameters in terms of time of emission acquisition per axial field of view (aFOV) and slice overlap between sequential aFOVs were used during the 3D acquisitions. 3D and 2D images were reconstructed using FORE+WLS and OSEM respectively. Scatter correction was performed by convolution subtraction and a model-based scatter correction in 2D and 3D respectively. All WB images were attenuation corrected using segmented transmission scans. Images were blindly assessed by three observers for the presence of artefacts, confidence in lesion detection and overall image quality using a scoring system. Statistically significant differences between 2D and 3D image quality were only obtained for 3D emission acquisitions of 3 min. No statistically significant differences were observed for image artefacts or lesion detectability scores. Image quality correlated significantly with patient weight for both modes of operation. Finally, no differences were seen in image artefact scores for the different axial slice overlaps considered, suggesting the use of five slice overlaps in 3D WB acquisitions. 3D WB imaging using a dedicated BGO-based PET scanner offers similar image quality to that obtained in 2D considering similar overall times of acquisitions. (orig.)

  14. PET with a dual-head coincidence gamma camera in head and neck cancer: A comparison with computed tomography and dedicated PET

    International Nuclear Information System (INIS)

    Zimny, M.

    2001-01-01

    Positron emission tomography with 18 F-fluoro-deoxyglucose (FDG PET) is a promising imaging tool for detecting and staging of primary or recurrent head and neck cancer. The aim of this study was to evaluate a dual-head gamma camera modified for coincidence detection (KGK-PET) in comparison to computed tomography (CT) and dedicated PET (dPET). 50 patients with known or suspected primary or recurrent head and neck cancer were enrolled. 32 patients underwent KGK-PET and dPET using a one-day protocol. The sensitivity for the detection of primary/ recurrent head and neck cancer for KGK-PET and CT was 80% and 54%, respectively, specificity was 73% and 82%, respectively. The sensitivity and specificity for the detection of lymph node metastases based on neck sides with KGK-PET was 71% (CT: 65%) and 88% (CT: 89%) respectively. In comparison to dPET, KGK-PET revealed concordant results in 32/32 patients with respect to primary tumor/recurrent disease and in 55/60 evaluated neck sides. All involved neck sides that were missed by KGK-PET were also negative with dPET. These results indicate that in patients with head and neck cancer KGK-PET reveals information, that are similar to dPET and complementary to CT. (orig.) [de

  15. Time of flight measurements based on FPGA using a breast dedicated PET

    International Nuclear Information System (INIS)

    Aguilar, A; García-Olcina, R; Martos, J; Soret, J; Torres, J; Benlloch, J M; González, A J; Sánchez, F

    2014-01-01

    In this work the implementation of a Time-to-Digital Converter (TDC) using a Nutt delay line FPGA-based and applied on a Positron Emission Tomography (PET) device is going to be presented in order to check the system's suitability for Time of Flight (TOF) measurements. In recent years, FPGAs have shown great advantages for precise time measurements in PET. The architecture employed for these measurements is described in detail. The system developed was tested on a dedicated breast PET prototype, composed of LYSO crystals and Positive Sensitive Photomultipliers (PSPMTs). Two distinct experiments were carried out for this purpose. In the first test, system linearity was evaluated in order to calibrate the time measurements, providing a linearity error of less than 2% and an average time resolution of 1.4 ns FWHM. The second set of measurements tested system resolution, resulting in a FWHM as good as 1.35 ns. The results suggest that the coincidence window for the current PET can be reduced in order to minimize the random events and thus, achieve better image quality

  16. Dedicated mobile high resolution prostate PET imager with an insertable transrectal probe

    Science.gov (United States)

    Majewski, Stanislaw; Proffitt, James

    2010-12-28

    A dedicated mobile PET imaging system to image the prostate and surrounding organs. The imaging system includes an outside high resolution PET imager placed close to the patient's torso and an insertable and compact transrectal probe that is placed in close proximity to the prostate and operates in conjunction with the outside imager. The two detector systems are spatially co-registered to each other. The outside imager is mounted on an open rotating gantry to provide torso-wide 3D images of the prostate and surrounding tissue and organs. The insertable probe provides closer imaging, high sensitivity, and very high resolution predominately 2D view of the prostate and immediate surroundings. The probe is operated in conjunction with the outside imager and a fast data acquisition system to provide very high resolution reconstruction of the prostate and surrounding tissue and organs.

  17. Feasibility of a brain-dedicated PET-MRI system using four-layer DOI detectors integrated with an RF head coil

    International Nuclear Information System (INIS)

    Nishikido, F.; Obata, T.; Shimizu, K.; Suga, M.; Inadama, N.; Tachibana, A.; Yoshida, E.; Ito, H.; Yamaya, T.

    2014-01-01

    We are developing a PET-MRI system which consists of PET detectors integrated with the head coil of the MRI in order to realize high spatial resolution and high sensitivity in simultaneous measurements. In the PET-MRI system, the PET detectors which consist of a scintillator block, photo-detectors and front-end circuits with four-layer depth-of-interaction (DOI) encoding capability are placed close to the measured object. Therefore, the proposed system can achieve high sensitivity without degradation of spatial resolution at the edge of the field-of-view due to parallax error thanks to the four-layer DOI capability. In this paper, we fabricated a prototype system which consists of a prototype four-layer DOI-PET detector, a dummy PET detector and a prototype birdcage type head coil. Then we used the prototype system to evaluate the performance of the four-layer DOI-PET detector and the reciprocal influence between the PET detectors and MRI images. The prototype DOI-PET detector consists of six monolithic multi-pixel photon counter (MPPC) arrays (S11064-050P), a readout circuit board, two scintillator blocks and a copper shielding box. Each scintillator block consists of four layers of Lu 1.8 Gd 0.2 SiO 5 :Ce (LGSO) scintillators and reflectors are inserted between the scintillation crystals. The dummy detector has all these components except the two scintillator blocks. The head coil is dedicated to a 3.0 T MRI (MAGNETOM Verio, Siemens) and the two detectors are mounted in gaps between head coil elements. Energy resolution and crystal identification performance of the prototype four-layer DOI-PET detector were evaluated with and without MRI measurements by the gradient echo and spin echo methods. We identified crystal elements in all four layers from a 2D flood histogram and energy resolution of 15–18% was obtained for single crystal elements in simultaneous measurements. The difference between the average energy resolutions and photo-peak positions with and

  18. Study and development of a PET device dedicated to cancer monitoring

    International Nuclear Information System (INIS)

    Vandenbussche, Vincent

    2014-01-01

    Medical imaging first began at the end of the 19. century with the discover of X-rays by Roentgen. Then, numerous imaging modalities have been developed and are used now for a wide range of cases. Positron Emission Tomography (PET) has a high sensitivity, is functional and quantitative, thus being of high interest in cancer monitoring. Nevertheless, PET is not as much spread in hospitals as magnetic resonance imaging and scanner. In this context, this work aims to prove the feasibility of PET dedicated for cancer monitoring. Thanks to instrumental developments such as light sharing in scintillating crystals, use of Silicon Photomultipliers, and an original geometry, cost is expected to be reduced while having same performances as commercial devices. An extensive study of light sharing within scintillating barrels has been made, through many parameters (crystal length, coating, data analysis...). An intrinsic spatial resolution of 4 mm has been measured over a 75 mm long crystal of LYSO, coated with teflon. From such a configuration, a first image has been reconstructed using two modules in coincidence. A spatial resolution of 5 mm has been measured in the image. Finally, Monte Carlo simulations has been made with experimental data as input, in order to measure the performances of the final PET device. Thanks to NEMA standard protocol, performances has been measured and compared to other systems. A spatial resolution of 4 mm has been reached, for a sensitivity of 2.5 cps/kBq. Quantification problem has been assessed, providing results similar to existing devices. (author) [fr

  19. Doses to nuclear technicians in a dedicated PET/CT centre utilising 18F fluorodeoxyglucose (FDG)

    International Nuclear Information System (INIS)

    Seierstad, T.; Stranden, E.; Bjering, K.; Evensen, M.; Holt, A.; Michalsen, H. M.; Wetteland, O.

    2007-01-01

    The first dedicated PET/CT centre in Norway was established at the Norwegian Radiumhospital in Oslo in 2005. Knowing that the introductions of PET-isotopes in nuclear medicine give increased occupational radiation dose to the technicians, a study was carried out in order to map the doses to staff members during different working operations and to see if any dose reducing measures were needed. The results of the study are in good agreement with other studies, and a technician dose of 20-25 nSv per injected MBq of 18 F seems to be representative for such centres. For an average injected activity of 350 MBq per patient, the dose limit is reached after handling around 3000 patients annually. For an annual number of less than 500 patients at the centre and rotation of the staff, an annual individual dose for the technicians would realistically be less than 2-3 mSv. Even a major increase in the number of patients will not result in individual doses near the ICRP dose limit. (authors)

  20. A comparison of dedicated and hybrid PET imaging in detection of recurrences of colorectal cancer with [18]-FDG

    International Nuclear Information System (INIS)

    Montravers, F.; Grahek, D.; Kerrou, K.; Younsi, N.; Petegnief, Y.; Talbot, J.N.

    2002-01-01

    Full text: The aim of this study was to assess the clinical performances of FDG using a CDET system (hybrid dual-head MARCONI gamma camera with sodium iodine crystal 19 mm flick) or a dedicated PET system (C-PET, ADAC) for the detection of colorectal cancer recurrences. We report an experience of 4 years with CDET (July 1997 - July 2001) and of 1.5 years with PET (January 2000 - July 2001). After fasting for 6h or more, 3-5 MBq/kg (for 2D - CDET) or 2 MBq/kg (for 3D - PET) of [18F]-FDG were injected i.v. and imaging (whole-body scan and at least one tomoscintigram for CDET or scanning of the torso for PET) was started one hour later. Reconstruction was performed by an iterative algorithm. Attenuation correction by an external source was only available for PET. 304 examinations (ex) were performed with CDET and 164 with PET. 230 CDET cases and 73 PET cases are currently available according to histology or to follow-up. These examinations were performed for suspicion of recurrence (157 CDET cases, 39 PET cases), in search for other localization when one or more resectable lesion(s) was (were) known (48 CDET cases, 24 CDET cases) or for evaluation of the therapeutic efficacy (25 CDET cases, 10 PET cases). Globally, sensitivity was 89 % with CDET and 92 % with PET, specificity was 93 % with CDET and 100 % with PET and accuracy was 90 % with CDET and 93 % with PET. These results confirmed that FDG is a powerful tool for the detection of colorectal recurrences and showed that no significative difference in accuracy (chi2 = .75 ; p = .4) was detectable between the two modalities interpreted by the same team and both performed 1 hour after injection. (author)

  1. The Siemens vision

    CSIR Research Space (South Africa)

    Van Dijk, B

    2017-10-01

    Full Text Available engagement Siemens Centre of Knowledge Interchange (CKI) • Partnership and collaboration with Universities • Industry specific • Multi-million investment, annually Siemens mentors • All Siemens employees actively encouraged to engage with schools.... Siemens is an engineering company. Vision 2020 “we make what matters” including the next generation of engineers make a difference, change the world. > €20M annual donations to education. Siemens ownership culture 348,000 employees...

  2. Incremental clinical value of a dedicated RT planning FDG PET-CT over staging PET-CT in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Lin, P.; Som, S.; Vinod, S.; Lin, M.; Shon, I. H.

    2009-01-01

    Full text:Objectives: To evaluate whether FDG-PET performed for radiotherapy planning can detect disease progression, compared with staging PET. Methods: Thirteen patients underwent a planning PET-CT for curative RT ( R T-PET ) within eight weeks of a staging PET-CT for newly diagnosed NSCLC between 10/2007 and 1/2009. All studies were acquired on a Philips GXL PET-CT using the same protocols, except RT-PET is acquired on a RT flat bed. The images were interpreted by consensus readings of two physicians: location/number, visual grading (0-4:3> liver, 4>brain), max transverse diameter ( M ax D ) (tumour margin is delineated by a SUV threshold of 2.5) and max SUV of each lesion. Progressive disease (PD) is defined as >10% increase in max D. Results: RT-PET detected PD (primary or nodal) or new metastases in 8 pts (61%) (mean interval:30.2±14 days, range:7-54 days). For primary tumour, RT-PET detected PD in 5 pts (range: 12-32% increase in max D and 12-39% increase in SUV) and RT-CT detected PD in 3 pts (11-21% increase in max D, paired t test: p = 0.19). Stage-PET detected 28 mediastinal/hilar nodal sites. RT-PET detected PD in 11 of these lesions in 4 pts (31%) and CT detected similar progression in 8 lesions in 2 pts. RT-PET detected 10 new lesions in 3 pts (23%) resulting in upstaging to N3 in 2 pts (supraclavicular and hilar nodes) and M1 in 1 pt (bone). Conclusion: A dedicated RT PET-CT has the potential to detect disease progression and impact on RT planning in a large number of patients.

  3. PET/MRI for Oncologic Brain Imaging: A Comparison of Standard MR-Based Attenuation Corrections with a Model-Based Approach for the Siemens mMR PET/MR System.

    Science.gov (United States)

    Rausch, Ivo; Rischka, Lucas; Ladefoged, Claes N; Furtner, Julia; Fenchel, Matthias; Hahn, Andreas; Lanzenberger, Rupert; Mayerhoefer, Marius E; Traub-Weidinger, Tatjana; Beyer, Thomas

    2017-09-01

    The aim of this study was to compare attenuation-correction (AC) approaches for PET/MRI in clinical neurooncology. Methods: Forty-nine PET/MRI brain scans were included: brain tumor studies using 18 F-fluoro-ethyl-tyrosine ( 18 F-FET) ( n = 31) and 68 Ga-DOTANOC ( n = 7) and studies of healthy subjects using 18 F-FDG ( n = 11). For each subject, MR-based AC maps (MR-AC) were acquired using the standard DIXON- and ultrashort echo time (UTE)-based approaches. A third MR-AC was calculated using a model-based, postprocessing approach to account for bone attenuation values (BD, noncommercial prototype software by Siemens Healthcare). As a reference, AC maps were derived from patient-specific CT images (CTref). PET data were reconstructed using standard settings after AC with all 4 AC methods. We report changes in diagnosis for all brain tumor patients and the following relative differences values (RDs [%]), with regards to AC-CTref: for 18 F-FET (A)-SUVs as well as volumes of interest (VOIs) defined by a 70% threshold of all segmented lesions and lesion-to-background ratios; for 68 Ga-DOTANOC (B)-SUVs as well as VOIs defined by a 50% threshold for all lesions and the pituitary gland; and for 18 F-FDG (C)-RD of SUVs of the whole brain and 10 anatomic regions segmented on MR images. Results: For brain tumor imaging (A and B), the standard PET-based diagnosis was not affected by any of the 3 MR-AC methods. For A, the average RDs of SUV mean were -10%, -4%, and -3% and of the VOIs 1%, 2%, and 7% for DIXON, UTE, and BD, respectively. Lesion-to-background ratios for all MR-AC methods were similar to that of CTref. For B, average RDs of SUV mean were -11%, -11%, and -3% and of the VOIs 1%, -4%, and -3%, respectively. In the case of 18 F-FDG PET/MRI (C), RDs for the whole brain were -11%, -8%, and -5% for DIXON, UTE, and BD, respectively. Conclusion: The diagnostic reading of PET/MR patients with brain tumors did not change with the chosen AC method. Quantitative accuracy of

  4. Development of a circular shape Si-PM-based detector ring for breast-dedicated PET system

    Science.gov (United States)

    Nakanishi, Kouhei; Yamamoto, Seiichi; Watabe, Hiroshi; Abe, Shinji; Fujita, Naotoshi; Kato, Katsuhiko

    2018-02-01

    In clinical situations, various breast-dedicated positron emission tomography (PET) systems have been used. However, clinical breast-dedicated PET systems have polygonal detector ring. Polygonal detector ring sometimes causes image artifact, so complicated reconstruction algorithm is needed to reduce artifact. Consequently, we developed a circular detector ring for breast-dedicated PET to obtain images without artifact using a simple reconstruction algorithm. We used Lu1.9Gd0.1SiO5 (LGSO) scintillator block which was made of 1.5 x 1.9 x 15 mm pixels that were arranged in an 8 x 24 matrix. As photodetectors, we used silicon photomultiplier (Si-PM) arrays whose channel size was 3 x 3 mm. A detector unit was composed of four scintillator blocks, 16 Si-PM arrays and a light guide. The developed detector unit had angled configuration since the light guide was bending. A detector unit had three gaps with an angle of 5.625° between scintillator blocks. With these configurations, we could arrange 64 scintillator blocks in nearly circular shape (regular 64-sided polygon) using 16 detector units. The use of the smaller number of detector units could reduce the size of the front-end electronics circuits. The inner diameter of the developed detector ring was 260 mm. This size was similar to those of brain PET systems, so our breast-dedicated PET detector ring can measure not only breast but also brain. Measured radial, tangential and axial spatial resolution of the detector ring reconstructed by the filtered back-projection (FBP) algorithm were 2.1 mm FWHM, 2.0 mm FWHM and 1.7 mm FWHM at center of field of view (FOV), respectively. The sensitivity was 2.0% at center of the axial FOV. With the developed detector ring, we could obtain high resolution image of the breast phantom and the brain phantom. We conclude that our developed Si-PM-based detector ring is promising for a high resolution breast-dedicated PET system that can also be used for brain PET system.

  5. Monte Carlo modeling of a clinical PET scanner by using the GATE dedicated computer code

    International Nuclear Information System (INIS)

    Vieira, Igor Fagner; Lima, Fernando Roberto de Andrade

    2011-01-01

    This paper demonstrates more possible detailed the GATE simulated architecture involved in the 4D modeling of a General Electric PET scanner, the Advance. So, it were used data present in the literature on the configuration of GE modelled PET. The obtained results which were the 3D components of PET creation, and the simulation of 4D phenomena as the source decay and the gantry whirl, exhibit the potential of tool in emission tomograph modelling

  6. Value of coincidence gamma camera PET for diagnosing head and neck tumors: functional imaging and image coregistration

    International Nuclear Information System (INIS)

    Dresel, S.; Brinkbaeumer, K.; Schmid, R.; Hahn, K.

    2001-01-01

    54 patients suffering from head and neck tumors (30 m, 24 f, age: 32-67 years) were examined using dedicated PET and coincidence gamma camera PET after injection of 185-350 MBq [ 18 F]FDG. Examinations were carried out on the dedicated PET first (Siemens ECAT Exact HR+) followed by a scan on the coincidence gamma camera PET (Picker Prism 2000 XP-PCD, Marconi Axis g-PET 2 AZ). Dedicated PET was acquired in 3D mode, coincidence gamma camera PET was performed in list mode using an axial filter. Reconstruction of data was performed iteratively on both, dedicated PET and coincidence gamma camera PET. All patients received a CT scan in multislice technique (Siemens Somatom Plus 4, Marconi MX 8000). Image coregistration was performed on an Odyssey workstation (Marconi). All findings have been verified by the gold standard histology or in case of negative histology by follow-up. Results: Using dedicated PET the primary or recurrent lesion was correctly diagnosed in 47/48 patients, using coincidence gamma camera PET in 46/48 patients and using CT in 25/48 patients. Metastatic disease in cervical lymph nodes was diagnosed in 17/18 patients with dedicated PET, in 16/18 patients with coincidence gamma camera PET and in 15/18 with CT. False-positive results with regard to lymph node metastasis were seen with one patient for dedicated PET and hybrid PET, respectively, and with 18 patients for CT. In a total of 11 patients unknown metastatic lesions were seen with dedicated PET and with coincidence gamma camera PET elsewhere in the body (lung: n = 7, bone: n = 3, liver: n = 1). Additional malignant disease other than the head and neck tumor was found in 4 patients. (orig.) [de

  7. {sup 18}F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters

    Energy Technology Data Exchange (ETDEWEB)

    Mhlanga, Joyce C.; Lodge, Martin [Johns Hopkins University School of Medicine, Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Carrino, John A. [Johns Hopkins University School of Medicine, Division of Musculoskeletal Radiology, The Russell H. Morgan Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Wang, Hao [Johns Hopkins University School of Medicine, Department of Oncology Biostatistics Division, Baltimore, MD (United States); Wahl, Richard L. [Johns Hopkins University School of Medicine, Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Johns Hopkins University Hospitals, Division of Nuclear Medicine, Baltimore, MD (United States)

    2014-12-15

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with {sup 18}F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological {sup 18}F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p= 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted. (orig.)

  8. First full-beam PET acquisitions in proton therapy with a modular dual-head dedicated system

    Science.gov (United States)

    Sportelli, G.; Belcari, N.; Camarlinghi, N.; Cirrone, G. A. P.; Cuttone, G.; Ferretti, S.; Kraan, A.; Ortuño, J. E.; Romano, F.; Santos, A.; Straub, K.; Tramontana, A.; Del Guerra, A.; Rosso, V.

    2014-01-01

    During particle therapy irradiation, positron emitters with half-lives ranging from 2 to 20 min are generated from nuclear processes. The half-lives are such that it is possible either to detect the positron signal in the treatment room using an in-beam positron emission tomography (PET) system, right after the irradiation, or to quickly transfer the patient to a close PET/CT scanner. Since the activity distribution is spatially correlated with the dose, it is possible to use PET imaging as an indirect method to assure the quality of the dose delivery. In this work, we present a new dedicated PET system able to operate in-beam. The PET apparatus consists in two 10 cm × 10 cm detector heads. Each detector is composed of four scintillating matrices of 23 × 23 LYSO crystals. The crystal size is 1.9 mm × 1.9 mm × 16 mm. Each scintillation matrix is read out independently with a modularized acquisition system. The distance between the two opposing detector heads was set to 20 cm. The system has very low dead time per detector area and a 3 ns coincidence window, which is capable to sustain high single count rates and to keep the random counts relatively low. This allows a new full-beam monitoring modality that includes data acquisition also while the beam is on. The PET system was tested during the irradiation at the CATANA (INFN, Catania, Italy) cyclotron-based proton therapy facility. Four acquisitions with different doses and dose rates were analysed. In all cases the random to total coincidences ratio was equal or less than 25%. For each measurement we estimated the accuracy and precision of the activity range on a set of voxel lines within an irradiated PMMA phantom. Results show that the inclusion of data acquired during the irradiation, referred to as beam-on data, improves both the precision and accuracy of the range measurement with respect to data acquired only after irradiation. Beam-on data alone are enough to give precisions better than 1 mm

  9. First full-beam PET acquisitions in proton therapy with a modular dual-head dedicated system

    International Nuclear Information System (INIS)

    Sportelli, G; Belcari, N; Camarlinghi, N; Ferretti, S; Kraan, A; Straub, K; Guerra, A Del; Rosso, V; Cirrone, G A P; Cuttone, G; Romano, F; Tramontana, A; Ortuño, J E; Santos, A

    2014-01-01

    During particle therapy irradiation, positron emitters with half-lives ranging from 2 to 20 min are generated from nuclear processes. The half-lives are such that it is possible either to detect the positron signal in the treatment room using an in-beam positron emission tomography (PET) system, right after the irradiation, or to quickly transfer the patient to a close PET/CT scanner. Since the activity distribution is spatially correlated with the dose, it is possible to use PET imaging as an indirect method to assure the quality of the dose delivery. In this work, we present a new dedicated PET system able to operate in-beam. The PET apparatus consists in two 10 cm × 10 cm detector heads. Each detector is composed of four scintillating matrices of 23 × 23 LYSO crystals. The crystal size is 1.9 mm × 1.9 mm × 16 mm. Each scintillation matrix is read out independently with a modularized acquisition system. The distance between the two opposing detector heads was set to 20 cm. The system has very low dead time per detector area and a 3 ns coincidence window, which is capable to sustain high single count rates and to keep the random counts relatively low. This allows a new full-beam monitoring modality that includes data acquisition also while the beam is on. The PET system was tested during the irradiation at the CATANA (INFN, Catania, Italy) cyclotron-based proton therapy facility. Four acquisitions with different doses and dose rates were analysed. In all cases the random to total coincidences ratio was equal or less than 25%. For each measurement we estimated the accuracy and precision of the activity range on a set of voxel lines within an irradiated PMMA phantom. Results show that the inclusion of data acquired during the irradiation, referred to as beam-on data, improves both the precision and accuracy of the range measurement with respect to data acquired only after irradiation. Beam-on data alone are enough to give precisions better than 1

  10. Image-quality assessment for several positron emitters using the nema nu 4-2009 standards in the siemens inveon small-animal pet scanner

    NARCIS (Netherlands)

    Disselhorst, J.A.; Brom, M.; Laverman, P.; Slump, Cornelis H.; Boerman, O.C.; Oyen, W.J.G.; Gotthardt, M.; Visser, E.P.

    2010-01-01

    The positron emitters 18F, 68Ga, 124I, and 89Zr are all relevant in small-animal PET. Each of these radionuclides has different positron energies and ranges and a different fraction of single photons emitted. Average positron ranges larger than the intrinsic spatial resolution of the scanner (for

  11. Image-quality assessment for several positron emitters using the NEMA NU 4-2008 standards in the Siemens Inveon small-animal PET scanner.

    NARCIS (Netherlands)

    Disselhorst, J.A.; Brom, M.; Laverman, P.; Slump, C.H.; Boerman, O.C.; Oyen, W.J.G.; Gotthardt, M.; Visser, E.P.

    2010-01-01

    The positron emitters (18)F, (68)Ga, (124)I, and (89)Zr are all relevant in small-animal PET. Each of these radionuclides has different positron energies and ranges and a different fraction of single photons emitted. Average positron ranges larger than the intrinsic spatial resolution of the scanner

  12. Clear-PEM: A dedicated PET camera for improved breast cancer detection

    International Nuclear Information System (INIS)

    Abreu, M. C.; Almeida, P.; Balau, F.; Ferreira, N. C.; Fetal, S.; Fraga, F.; Martins, M.; Matela, N.; Moura, R.; Ortigao, C.; Peralta, L.; Rato, P.; Ribeiro, R.; Rodrigues, P.; Santos, A. I.; Trindade, A.; Varela, J.

    2005-01-01

    Positron emission mammography (PEM) can offer a non-invasive method for the diagnosis of breast cancer. Metabolic images from PEM using 18 F-fluoro-deoxy-glucose, contain unique information not available from conventional morphologic imaging techniques like X-ray radiography. In this work, the concept of Clear-PEM, the system presently developed in the frame of the Crystal Clear Collaboration at CERN, is described. Clear-PEM will be a dedicated scanner, offering better perspectives in terms of position resolution and detection sensitivity. (authors)

  13. Clear-PEM: A PET imaging system dedicated to breast cancer diagnostics

    CERN Document Server

    Abreu, M C; Albuquerque, E; Almeida, F G; Almeida, P; Amaral, P; Auffray, Etiennette; Bento, P; Bruyndonckx, P; Bugalho, R; Carriço, B; Cordeiro, H; Ferreira, M; Ferreira, N C; Gonçalves, F; Lecoq, Paul; Leong, C; Lopes, F; Lousã, P; Luyten, J; Martins, M V; Matela, N; Rato-Mendes, P; Moura, R; Nobre, J; Oliveira, N; Ortigão, C; Peralta, L; Rego, J; Ribeiro, R; Rodrigues, P; Santos, A I; Silva, J C; Silva, M M; Tavernier, Stefaan; Teixeira, I C; Texeira, J P; Trindade, A; Trummer, Julia; Varela, J

    2007-01-01

    The Clear-PEM scanner for positron emission mammography under development is described. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes and readout by a fast low-noise electronic system. A dedicated digital trigger (TGR) and data acquisition (DAQ) system is used for on-line selection of coincidence events with high efficiency, large bandwidth and small dead-time. A specialized gantry allows to perform exams of the breast and of the axilla. In this paper we present results of the measurement of detector modules that integrate the system under construction as well as the imaging performance estimated from Monte Carlo simulated data.

  14. A prototype PET/SPECT/X-rays scanner dedicated for whole body small animal studies.

    Science.gov (United States)

    Rouchota, Maritina; Georgiou, Maria; Fysikopoulos, Eleftherios; Fragogeorgi, Eirini; Mikropoulos, Konstantinos; Papadimitroulas, Panagiotis; Kagadis, George; Loudos, George

    2017-01-01

    To present a prototype tri-modal imaging system, consisting of a single photon emission computed tomography (SPET), a positron emission tomography (PET), and a computed tomography (CT) subsystem, evaluated in planar mode. The subsystems are mounted on a rotating gantry, so as to be able to allow tomographic imaging in the future. The system, designed and constructed by our group, allows whole body mouse imaging of competent performance and is currently, to the best of our knowledge, unequaled in a national and regional level. The SPET camera is based on two Position Sensitive Photomultiplier Tubes (PSPMT), coupled to a pixilated Sodium Iodide activated with Thallium (NaI(Tl)) scintillator, having an active area of 5x10cm 2 . The dual head PET camera is also based on two pairs of PSPMT, coupled to pixelated berillium germanium oxide (BGO) scintillators, having an active area of 5x10cm 2 . The X-rays system consists of a micro focus X-rays tube and a complementary metal-oxide-semiconductor (CMOS) detector, having an active area of 12x12cm 2 . The scintigraphic mode has a spatial resolution of 1.88mm full width at half maximum (FWHM) and a sensitivity of 107.5cpm/0.037MBq at the collimator surface. The coincidence PET mode has an average spatial resolution of 3.5mm (FWHM) and a peak sensitivity of 29.9cpm/0.037MBq. The X-rays spatial resolution is 3.5lp/mm and the contrast discrimination function value is lower than 2%. A compact tri-modal system was successfully built and evaluated for planar mode operation. The system has an efficient performance, allowing accurate and informative anatomical and functional imaging, as well as semi-quantitative results. Compared to other available systems, it provides a moderate but comparable performance, at a fraction of the cost and complexity. It is fully open, scalable and its main purpose is to support groups on a national and regional level and provide an open technological platform to study different detector components and

  15. Design study of a high-resolution breast-dedicated PET system built from cadmium zinc telluride detectors

    International Nuclear Information System (INIS)

    Peng Hao; Levin, Craig S

    2010-01-01

    We studied the performance of a dual-panel positron emission tomography (PET) camera dedicated to breast cancer imaging using Monte Carlo simulation. The proposed system consists of two 4 cm thick 12 x 15 cm 2 area cadmium zinc telluride (CZT) panels with adjustable separation, which can be put in close proximity to the breast and/or axillary nodes. Unique characteristics distinguishing the proposed system from previous efforts in breast-dedicated PET instrumentation are the deployment of CZT detectors with superior spatial and energy resolution, using a cross-strip electrode readout scheme to enable 3D positioning of individual photon interaction coordinates in the CZT, which includes directly measured photon depth-of-interaction (DOI), and arranging the detector slabs edge-on with respect to incoming 511 keV photons for high photon sensitivity. The simulation results show that the proposed CZT dual-panel PET system is able to achieve superior performance in terms of photon sensitivity, noise equivalent count rate, spatial resolution and lesion visualization. The proposed system is expected to achieve ∼32% photon sensitivity for a point source at the center and a 4 cm panel separation. For a simplified breast phantom adjacent to heart and torso compartments, the peak noise equivalent count (NEC) rate is predicted to be ∼94.2 kcts s -1 (breast volume: 720 cm 3 and activity concentration: 3.7 kBq cm -3 ) for a ∼10% energy window around 511 keV and ∼8 ns coincidence time window. The system achieves 1 mm intrinsic spatial resolution anywhere between the two panels with a 4 cm panel separation if the detectors have DOI resolution less than 2 mm. For a 3 mm DOI resolution, the system exhibits excellent sphere resolution uniformity (σ rms /mean) ≤ 10%) across a 4 cm width FOV. Simulation results indicate that the system exhibits superior hot sphere visualization and is expected to visualize 2 mm diameter spheres with a 5:1 activity concentration ratio within

  16. The Siemens graduate program

    International Nuclear Information System (INIS)

    Schaeffler, I.

    2000-01-01

    Siemens is an international company acting in different domains: power generation, communication and information, traffic, health, etc. To be more flexible and active in a world in constant evolution, the company proposes a graduate program where young people with a special background have the possibility to start an international career in all the domains of activity. This graduate program is especially important in the domain of nuclear energy, where the know-how transfer between the previous generation and the new one is a constant point of interest. This article presents the conditions to be accepted in this graduate program, and the supplementary training supporting this program. The Siemens graduate program (Sg) proposes a global concept with a main emphasis being international. (authors)

  17. ROKCY-12 (KCCH PET-dedicated cyclotron): main features and improvements

    International Nuclear Information System (INIS)

    Chai, J. S.; Kim, Y. S.; Yang, Y. T.; Jung, I. S.; Hong, S. S.; Lee, M. Y.; Jang, H. S.; Kim, J. H.

    2002-01-01

    In this paper, we describe the development of 13 MeV cyclotron (ROKCY-12) that can be used for a Position Emission Tomography(PET) purpose. This cyclotron with a maximum beam energy of 13 MeV can produce radio isotopes especially 18 F which has a relatively short half lifetime of 110 minutes. First, we show the beam characteristics can be used to carry out the operation of ROCKY-12. Based on this, a computer program has been developed to determine main cyclotron parameters such as cyclotron magnet, RF system, ion source, vacuum system and other cyclotron operation parameters. And then we show the result of design and manufacturing feature of ROKCY-12. By using this design program, one can determines magnet yoke geometry and the average magnetic fields etc. And then the three-dimensional computer program OPERA-3D has been invoked to determine magnet pole tips. Validity of the design can be seen by investigating magnetic fields, radial and vertical focusing frequencies as a function of the beam energy. In this paper, we show the results of cyclotron beam by ROCKY-12. We designed 77.3 MHz RF system and ion source system. We tested RF resonance each coupling methods. We show the result of RF design and prototype operation. Developed ion source is PIG type. We described our design methods and implementation. We report the result of getting negative hydrogen ion. Cyclotron controller asks inputs of every sensor and output of every instrument for notifying current condition to operator. It has independent controllers, for example DC power supply, vacuum system, beam profile system, beam extraction system, RF system, ion source, cooling unit and so on. Basically, each control system uses RS-485 for communication to main control computer. Consumers reward products and services that feature quality, originality, a distinct personality and charm. The International Standardization Organization (ISO) requires, as its mission, that we achieve competitive superiority by

  18. Characterization and performance of monolithic detector blocks with a dedicated ASIC front-end readout for PET imaging of the human brain

    International Nuclear Information System (INIS)

    Rato Mendes, Pedro; Sarasola Martin, Iciar; Canadas, Mario; Garcia de Acilu, Paz; Cuypers, Robin; Perez, Jose Manuel; Willmott, Carlos

    2011-01-01

    We are developing a human brain PET scanner prototype compatible with MRI based on monolithic scintillator crystals, APD matrices and a dedicated ASIC front-end readout. In this work we report on the performance of individual detector modules and on the operation of such modules in PET coincidence. Results will be presented on the individual characterization of detector blocks and its ASIC front-end readout, with measured energy resolutions of 13% full-width half-maximum (FWHM) at 511 keV and spatial resolutions of the order of 2 mm FWHM. First results on PET coincidence performance indicate spatial resolutions as good as 2.1 mm FWHM for SSRB/FBP reconstruction of tomographic data obtained using a simple PET demonstrator based on a pair of monolithic detector blocks with ASIC readout.

  19. Spatial resolution of the HRRT PET scanner using 3D-OSEM PSF reconstruction

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Sibomana, Merence; Keller, Sune Høgild

    2009-01-01

    The spatial resolution of the Siemens High Resolution Research Tomograph (HRRT) dedicated brain PET scanner installed at Copenhagen University Hospital (Rigshospitalet) was measured using a point-source phantom with high statistics. Further, it was demonstrated how the newly developed 3D-OSEM PSF...

  20. The Siemens graduate program

    International Nuclear Information System (INIS)

    Schaffler, I.

    2001-01-01

    SIEMENS is an international company acting in various domains: power generation, communication and information, traffic, health...etc. To increase flexibility and activity in a world in constant evolution, the company proposes a graduate program where young people with a special background have the possibility to start an international career in one of the different business areas. This graduate program is also very important in the domain of nuclear energy, where the know-how transfer between the previous generation and the new one is a constant point of interest. (author)

  1. Texture analysis of high-resolution dedicated breast {sup 18}F-FDG PET images correlates with immunohistochemical factors and subtype of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Moscoso, Alexis; Dominguez-Prado, Ines; Herranz, Michel; Argibay, Sonia; Silva-Rodriguez, Jesus [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); Ruibal, Alvaro [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); University of Santiago de Compostela (USC), Molecular Imaging Group, Department of Radiology, Faculty of Medicine, Santiago de Compostela (Spain); Fundacion Tejerina, Madrid (Spain); Fernandez-Ferreiro, Anxo [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Pharmacy Department and Pharmacology Group, Santiago de Compostela (Spain); Albaina, Luis [University Hospital A Coruna (SERGAS), Department of General Surgery, A Coruna (Spain); Pardo-Montero, Juan [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); Complexo Hospitalario Universitario de Santiago de Compostela (CHUS), Medical Physics Department, Santiago de Compostela (Spain); Aguiar, Pablo [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); University of Santiago de Compostela (USC), Molecular Imaging Group, Department of Radiology, Faculty of Medicine, Santiago de Compostela (Spain)

    2018-02-15

    This study aims to determine whether PET textural features measured with a new dedicated breast PET scanner reflect biological characteristics of breast tumors. One hundred and thirty-nine breast tumors from 127 consecutive patients were included in this analysis. All of them underwent a {sup 18}F-FDG PET scan before treatment. Well-known PET quantitative parameters such as SUV{sub m} {sub a} {sub x}, SUV{sub m} {sub e} {sub a} {sub n}, metabolically active tumor volume (MATV) and total lesion glycolysis (TLG) were extracted. Together with these parameters, local, regional, and global heterogeneity descriptors, which included five textural features (TF), were computed. Immunohistochemical classification of breast cancer considered five subtypes: luminal A like (LA), luminal B like/HER2 - (LB -), luminal B like/HER2+ (LB+), HER2-positive-non-luminal (HER2pnl), and triple negative (TN). Associations between PET features and tumor characteristics were assessed using non-parametric hypothesis tests. Along with well-established associations, new correlations were found. HER2-positive tumors had significantly higher uptake (p < 0.001, AUCs > 0.70) and presented different global and regional heterogeneity (p = 0.002, p = 0.016, respectively, AUCs < 0.70). Nine out of ten analyzed features were significantly associated with immunohistochemical subtype. Uptake was lower for LA tumors (p < 0.001) with AUCs ranging from 0.71 to 0.88 for each subgroup comparison. Heterogeneity metrics were significantly associated when comparing LA and LB - (p < 0.01), being regional heterogeneity metrics more discriminative than any other parameter (AUC = 0.80 compared to AUC = 0.71 for SUV). LB+ and HER2pnl tumors also showed more regional heterogeneity than LA tumors (AUCs = 0.79 and 0.84, respectively). After comparison with whole-body PET studies, we observed an overall improvement in the classification ability of both non-heterogeneity metrics and textural features. PET parameters

  2. Monte Carlo modeling of a clinical PET scanner by using the GATE dedicated computer code; Modelagem Monte Carlo de um PET Scanner clinico utilizando o codigo dedicado GATE

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Igor Fagner; Lima, Fernando Roberto de Andrade, E-mail: falima@cnen.gov.b [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Universidade de Pernambuco (UPE), Recife, PE (Brazil). Escola Politecnica; Vieira, Jose Wilson [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2011-10-26

    This paper demonstrates more possible detailed the GATE simulated architecture involved in the 4D modeling of a General Electric PET scanner, the Advance. So, it were used data present in the literature on the configuration of GE modelled PET. The obtained results which were the 3D components of PET creation, and the simulation of 4D phenomena as the source decay and the gantry whirl, exhibit the potential of tool in emission tomograph modelling

  3. Incremental clinical value of a dedicated RT planning FDG PET-CT over staging PET-CT in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Lin, P.; Som, S.; Vinod, S.; Lin, M.; Shon, I. H.

    2009-01-01

    Full text:Objectives: To evaluate whether FDG-PET performed for radiotherapy planning can detect disease progression, compared with staging PET. Methods: Thirteen patients underwent a planning PET-CT for curative RT ( R T-PET ) within eight weeks of a staging PET-CT for newly diagnosed NSCLC between 10/2007 and 1/2009. All studies were acquired on a Philips GXL PET-CT using the same protocols, except RT-PET is acquired on a RT flat bed. The images were interpreted by consensus readings of two physicians: location/number, visual grading (0-4:3> liver, 4>brain), max transverse diameter ( M ax D ) (tumour margin is delineated by a SUV threshold of 2.5) and max SUV of each lesion. Progressive disease (PD) is defined as >10% increase in max D. Results: RT-PET detected PD (primary or nodal) or new metastases in 8 pts (61%) (mean interval:30.2±14 days, range:7-54 days). For primary tumour, RT-PET detected PD in 5

  4. Added value of dedicated axillary hybrid 18F-FDG PET/MRI for improved axillary nodal staging in clinically node-positive breast cancer patients. A feasibility study

    International Nuclear Information System (INIS)

    Nijnatten, Thiemo J.A. van; Goorts, B.; Voeoe, S.; Wildberger, J.E.; Boer, M. de; Kooreman, L.F.S.; Heuts, E.M.; Mottaghy, F.M.; Lobbes, M.B.I.; Smidt, M.L.

    2018-01-01

    To investigate the feasibility and potential added value of dedicated axillary 18F-FDG hybrid PET/MRI, compared to standard imaging modalities (i.e. ultrasound [US], MRI and PET/CT), for axillary nodal staging in clinically node-positive breast cancer. Twelve patients with clinically node-positive breast cancer underwent axillary US and dedicated axillary hybrid 18F-FDG PET/MRI. Nine of the 12 patients also underwent whole-body PET/CT. Maximum standardized uptake values (SUVmax) were measured for the primary breast tumor and the most FDG-avid axillary lymph node. A positive axillary lymph node on dedicated axillary hybrid PET/MRI was defined as a moderate to very intense FDG-avid lymph node. The diagnostic performance of dedicated axillary hybrid PET/MRI was calculated by comparing quantitative and its qualitative measurements to results of axillary US, MRI and PET/CT. The number of suspicious axillary lymph nodes was subdivided as follows: N0 (0 nodes), N1 (1-3 nodes), N2 (4-9 nodes) and N3 (≥ 10 nodes). According to dedicated axillary hybrid PET/MRI findings, seven patients were diagnosed with N1, four with N2 and one with N3. With regard to mean SUVmax, there was no significant difference in the primary tumor (9.0 [±5.0] vs. 8.6 [±5.7], p = 0.678) or the most FDG-avid axillary lymph node (7.8 [±5.3] vs. 7.7 [±4.3], p = 0.767) between dedicated axillary PET/MRI and PET/CT. Compared to standard imaging modalities, dedicated axillary hybrid PET/MRI resulted in changes in nodal status as follows: 40% compared to US, 75% compared to T2-weighted MRI, 40% compared to contrast-enhanced MRI, and 22% compared to PET/CT. Adding dedicated axillary 18F-FDG hybrid PET/MRI to diagnostic work-up may improve the diagnostic performance of axillary nodal staging in clinically node-positive breast cancer patients. (orig.)

  5. Added value of dedicated axillary hybrid 18F-FDG PET/MRI for improved axillary nodal staging in clinically node-positive breast cancer patients. A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Nijnatten, Thiemo J.A. van; Goorts, B. [Maastricht University Medical Center+, Department of Radiology and Nuclear Medicine (Netherlands); Maastricht University Medical Center+, Department of Surgery, Maastricht (Netherlands); Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Voeoe, S.; Wildberger, J.E. [Maastricht University Medical Center+, Department of Radiology and Nuclear Medicine (Netherlands); Boer, M. de [Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Maastricht University Medical Center+, Division of Internal Medicine, Department of Medical Oncology, Maastricht (Netherlands); Kooreman, L.F.S. [Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Maastricht University Medical Center+, Department of Pathology, Maastricht (Netherlands); Heuts, E.M. [Maastricht University Medical Center+, Department of Surgery, Maastricht (Netherlands); Mottaghy, F.M. [Maastricht University Medical Center+, Department of Radiology and Nuclear Medicine (Netherlands); RWTH Aachen University, Department of Nuclear Medicine, University Hospital, Aachen (Germany); Lobbes, M.B.I. [Maastricht University Medical Center+, Department of Radiology and Nuclear Medicine (Netherlands); Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Smidt, M.L. [Maastricht University Medical Center+, Department of Surgery, Maastricht (Netherlands); Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands)

    2018-02-15

    To investigate the feasibility and potential added value of dedicated axillary 18F-FDG hybrid PET/MRI, compared to standard imaging modalities (i.e. ultrasound [US], MRI and PET/CT), for axillary nodal staging in clinically node-positive breast cancer. Twelve patients with clinically node-positive breast cancer underwent axillary US and dedicated axillary hybrid 18F-FDG PET/MRI. Nine of the 12 patients also underwent whole-body PET/CT. Maximum standardized uptake values (SUVmax) were measured for the primary breast tumor and the most FDG-avid axillary lymph node. A positive axillary lymph node on dedicated axillary hybrid PET/MRI was defined as a moderate to very intense FDG-avid lymph node. The diagnostic performance of dedicated axillary hybrid PET/MRI was calculated by comparing quantitative and its qualitative measurements to results of axillary US, MRI and PET/CT. The number of suspicious axillary lymph nodes was subdivided as follows: N0 (0 nodes), N1 (1-3 nodes), N2 (4-9 nodes) and N3 (≥ 10 nodes). According to dedicated axillary hybrid PET/MRI findings, seven patients were diagnosed with N1, four with N2 and one with N3. With regard to mean SUVmax, there was no significant difference in the primary tumor (9.0 [±5.0] vs. 8.6 [±5.7], p = 0.678) or the most FDG-avid axillary lymph node (7.8 [±5.3] vs. 7.7 [±4.3], p = 0.767) between dedicated axillary PET/MRI and PET/CT. Compared to standard imaging modalities, dedicated axillary hybrid PET/MRI resulted in changes in nodal status as follows: 40% compared to US, 75% compared to T2-weighted MRI, 40% compared to contrast-enhanced MRI, and 22% compared to PET/CT. Adding dedicated axillary 18F-FDG hybrid PET/MRI to diagnostic work-up may improve the diagnostic performance of axillary nodal staging in clinically node-positive breast cancer patients. (orig.)

  6. Strategy: Siemens sees green - Siemens after the atom

    International Nuclear Information System (INIS)

    Moragues, M.; Dupin, L.; Scherer, M.

    2011-01-01

    This article discusses the new strategy implemented by Peter Loescher, the Siemens' CEO, who has just announced that Siemens decided to stop working directly for the nuclear sector, and to be a pioneer in sustainable development. This means a reorganisation of this group which, beside its energy department, its industry department and health department, comprises an infrastructures and cities' department which gathers rail, electricity distribution, building technologies. It also means important investments in the renewable energy sector, and phasing out of the automotive, telecommunications and data processing hardware sectors. The challenges, opportunities, strengths and weaknesses of Siemens four pillars (energy, industry, health, and infrastructures) are discussed. An article also evokes the relationship of Siemens with the French nuclear industry

  7. Performance Evaluation of a Dedicated Preclinical PET/CT System for the Assessment of Mineralization Process in a Mouse Model of Atherosclerosis.

    Science.gov (United States)

    Rucher, Guillaume; Cameliere, Lucie; Fendri, Jihene; Abbas, Ahmed; Dupont, Kevin; Kamel, Said; Delcroix, Nicolas; Dupont, Axel; Berger, Ludovic; Manrique, Alain

    2018-04-30

    The purpose of this study was to assess the impact of positron emission tomography/X-ray computed tomography (PET/CT) acquisition and reconstruction parameters on the assessment of mineralization process in a mouse model of atherosclerosis. All experiments were performed on a dedicated preclinical PET/CT system. CT was evaluated using five acquisition configurations using both a tungsten wire phantom for in-plane resolution assessment and a bar pattern phantom for cross-plane resolution. Furthermore, the radiation dose of these acquisition configurations was calculated. The PET system was assessed using longitudinal line sources to determine the optimal reconstruction parameters by measuring central resolution and its coefficient of variation. An in vivo PET study was performed using uremic ApoE -/- , non-uremic ApoE -/- , and control mice to evaluate optimal PET reconstruction parameters for the detection of sodium [ 18 F]fluoride (Na[ 18 F]F) aortic uptake and for quantitative measurement of Na[ 18 F]F bone influx (Ki) with a Patlak analysis. For CT, the use of 1 × 1 and 2 × 2 binning detector mode increased both in-plane and cross-plane resolution. However, resolution improvement (163 to 62 μm for in-plane resolution) was associated with an important radiation dose increase (1.67 to 32.78 Gy). With PET, 3D-ordered subset expectation maximization (3D-OSEM) algorithm increased the central resolution compared to filtered back projection (1.42 ± 0.35 mm vs. 1.91 ± 0.08, p PET resolution for preclinical study (FWHM = 0.98 mm). These PET reconstruction parameters allowed the detection of Na[ 18 F]F aortic uptake in 3/14 ApoE -/- mice and demonstrated a decreased Ki in uremic ApoE -/- compared to non-uremic ApoE -/- and control mice (p PET. In addition, improving the CT resolution was associated with a dramatic radiation dose increase.

  8. BNFL/Siemens to merge?

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    Negotiations are being conducted on the creation of a joint venture between British Nuclear Fuels Limited (BNFL) and the German company Siemens. The venture would merge Siemens' nuclear fuel, engineering and construction services businesses with BNFL's Magnox and AGR fuel fabrication business which is based at Springfields in Lancashire. It would incorporate Siemens' share of Nuclear Power International, a joint venture with the French company Framatone which is developing the European Pressurised Water Reactor project, and its US subsidiary Siemens' Power Corp. BNFL's mixed oxide (MOX) fuel fabrication business, its stake in the Dutch-German-UK uranium enrichment company Urenco and its nuclear waste reprocessing business would not be involved. There is already speculation that Siemens' greater input will lead to it taking a majority stake in what will be the world's second largest nuclear fuel manufacturer. Reaction to the news is reported. This has been muted in the United Kingdom, mixed in Germany and adverse in France because of the implications for the Siemens' Framatone collaboration. (UK)

  9. Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET

    Science.gov (United States)

    Moliner, L.; Correcher, C.; González, A. J.; Conde, P.; Hernández, L.; Orero, A.; Rodríguez-Álvarez, M. J.; Sánchez, F.; Soriano, A.; Vidal, L. F.; Benlloch, J. M.

    2013-02-01

    In this work we present an innovative algorithm for the reconstruction of PET images based on the List-Mode (LM) technique which improves their spatial resolution compared to results obtained with current MLEM algorithms. This study appears as a part of a large project with the aim of improving diagnosis in early Alzheimer disease stages by means of a newly developed hybrid PET-MR insert. At the present, Alzheimer is the most relevant neurodegenerative disease and the best way to apply an effective treatment is its early diagnosis. The PET device will consist of several monolithic LYSO crystals coupled to SiPM detectors. Monolithic crystals can reduce scanner costs with the advantage to enable implementation of very small virtual pixels in their geometry. This is especially useful for LM reconstruction algorithms, since they do not need a pre-calculated system matrix. We have developed an LM algorithm which has been initially tested with a large aperture (186 mm) breast PET system. Such an algorithm instead of using the common lines of response, incorporates a novel calculation of tubes of response. The new approach improves the volumetric spatial resolution about a factor 2 at the border of the field of view when compared with traditionally used MLEM algorithm. Moreover, it has also shown to decrease the image noise, thus increasing the image quality.

  10. Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET

    International Nuclear Information System (INIS)

    Moliner, L.; Correcher, C.; González, A.J.; Conde, P.; Hernández, L.; Orero, A.; Rodríguez-Álvarez, M.J.; Sánchez, F.; Soriano, A.; Vidal, L.F.; Benlloch, J.M.

    2013-01-01

    In this work we present an innovative algorithm for the reconstruction of PET images based on the List-Mode (LM) technique which improves their spatial resolution compared to results obtained with current MLEM algorithms. This study appears as a part of a large project with the aim of improving diagnosis in early Alzheimer disease stages by means of a newly developed hybrid PET-MR insert. At the present, Alzheimer is the most relevant neurodegenerative disease and the best way to apply an effective treatment is its early diagnosis. The PET device will consist of several monolithic LYSO crystals coupled to SiPM detectors. Monolithic crystals can reduce scanner costs with the advantage to enable implementation of very small virtual pixels in their geometry. This is especially useful for LM reconstruction algorithms, since they do not need a pre-calculated system matrix. We have developed an LM algorithm which has been initially tested with a large aperture (186 mm) breast PET system. Such an algorithm instead of using the common lines of response, incorporates a novel calculation of tubes of response. The new approach improves the volumetric spatial resolution about a factor 2 at the border of the field of view when compared with traditionally used MLEM algorithm. Moreover, it has also shown to decrease the image noise, thus increasing the image quality

  11. Sub-millimetre DOI detector based on monolithic LYSO and digital SiPM for a dedicated small-animal PET system

    International Nuclear Information System (INIS)

    Marcinkowski, Radosław; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan

    2016-01-01

    The mouse model is widely used in a vast range of biomedical and preclinical studies. Thanks to the ability to detect and quantify biological processes at the molecular level in vivo, PET has become a well-established tool in these investigations. However, the need to visualize and quantify radiopharmaceuticals in anatomic structures of millimetre or less requires good spatial resolution and sensitivity from small-animal PET imaging systems. In previous work we have presented a proof-of-concept of a dedicated high-resolution small-animal PET scanner based on thin monolithic scintillator crystals and Digital Photon Counter photosensor. The combination of thin monolithic crystals and MLE positioning algorithm resulted in an excellent spatial resolution of 0.7 mm uniform in the entire field of view (FOV). However, the limitation of the scanner was its low sensitivity due to small thickness of the lutetium-yttrium oxyorthosilicate (LYSO) crystals (2 mm). Here we present an improved detector design for a small-animal PET system that simultaneously achieves higher sensitivity and sustains a sub-millimetre spatial resolution. The proposed detector consists of a 5 mm thick monolithic LYSO crystal optically coupled to a Digital Photon Counter. Mean nearest neighbour (MNN) positioning combined with depth of interaction (DOI) decoding was employed to achieve sub-millimetre spatial resolution. To evaluate detector performance the intrinsic spatial resolution, energy resolution and coincidence resolving time (CRT) were measured. The average intrinsic spatial resolution of the detector was 0.60 mm full-width-at-half-maximum (FWHM). A DOI resolution of 1.66 mm was achieved. The energy resolution was 23% FWHM at 511 keV and CRT of 529 ps were measured. The improved detector design overcomes the sensitivity limitation of the previous design by increasing the nominal sensitivity of the detector block and retains an excellent intrinsic spatial resolution. (paper)

  12. Feasibility of a novel design of high resolution parallax-free Compton enhanced PET scanner dedicated to brain research

    CERN Document Server

    Braem, André; Chesi, Enrico Guido; Correia, J G; Garibaldi, F; Joram, C; Mathot, S; Nappi, E; Ribeiro da Silva, M; Schoenahl, F; Séguinot, Jacques; Weilhammer, P; Zaidi, H

    2004-01-01

    A novel concept for a positron emission tomography (PET) camera module is proposed, which provides full 3D reconstruction with high resolution over the total detector volume, free of parallax errors. The key components are a matrix of long scintillator crystals and hybrid photon detectors (HPDs) with matched segmentation and integrated readout electronics. The HPDs read out the two ends of the scintillator package. Both excellent spatial (x, y, z) and energy resolution are obtained. The concept allows enhancing the detection efficiency by reconstructing a significant fraction of events which underwent Compton scattering in the crystals. The proof of concept will first be demonstrated with yttrium orthoaluminate perovskite (YAP):Ce crystals, but the final design will rely on other scintillators more adequate for PET applications (e.g. LSO:Ce or LaBr /sub 3/:Ce). A promising application of the proposed camera module, which is currently under development, is a high resolution 3D brain PET camera with an axial fi...

  13. SENSROC4: An Multichannel Low-Noise Front-End Readout ASIC Dedicated to CZT Detectors for PET Imaging

    International Nuclear Information System (INIS)

    Gao, W.; Liu, H.; Gao, D.; Gan, B.; Wei, T.; Hu, Y.

    2013-06-01

    In this paper, we present the design of a novel low-noise front-end readout application-specific integrated circuit (ASIC) for our small animal PET systems which objective is to achieve the following performances, the spatial resolution of 1 mm 3 , the detection efficiency of 15 % and the time resolution of 1 ns. A cascade amplifier based on the PMOS input transistor is selected to realize the charge-sensitive amplifier (CSA) for the sake of good noise performances. The output of the CSA is split into two branches. One is connected to a slow shaper for energy measurements. The other is connected to a fast shaper for time acquisition. A novel monostable circuit is designed to adjust the time delay of the trigger signals so that the peak value of the shaped voltages can be sampled and stored. Based on the above techniques, an eight-channel front-end readout prototype chip is designed and implemented in 0.35 μm CMOS process. The die size is 2.286 mm x 2.282 mm. The input range of the ASIC is from 2000 e- to 180000 e-, reflecting to the energy of the gamma ray from 11.2 keV to 1 MeV. The gain of the readout channel is 65 V/pC. The best test result of ENC is 86.5 e- at zero farad plus 9.3 e- per pico-farad. The nonlinearity is less than 3 %. The crosstalk is less than 2 %. The power dissipation is about 9 mW/channel (authors)

  14. Physical effects of mechanical design parameters on photon sensitivity and spatial resolution performance of a breast-dedicated PET system.

    Science.gov (United States)

    Spanoudaki, V C; Lau, F W Y; Vandenbroucke, A; Levin, C S

    2010-11-01

    This study aims to address design considerations of a high resolution, high sensitivity positron emission tomography scanner dedicated to breast imaging. The methodology uses a detailed Monte Carlo model of the system structures to obtain a quantitative evaluation of several performance parameters. Special focus was given to the effect of dense mechanical structures designed to provide mechanical robustness and thermal regulation to the minuscule and temperature sensitive detectors. For the energies of interest around the photopeak (450-700 keV energy window), the simulation results predict a 6.5% reduction in the single photon detection efficiency and a 12.5% reduction in the coincidence photon detection efficiency in the case that the mechanical structures are interspersed between the detectors. However for lower energies, a substantial increase in the number of detected events (approximately 14% and 7% for singles at a 100-200 keV energy window and coincidences at a lower energy threshold of 100 keV, respectively) was observed with the presence of these structures due to backscatter. The number of photon events that involve multiple interactions in various crystal elements is also affected by the presence of the structures. For photon events involving multiple interactions among various crystal elements, the coincidence photon sensitivity is reduced by as much as 20% for a point source at the center of the field of view. There is no observable effect on the intrinsic and the reconstructed spatial resolution and spatial resolution uniformity. Mechanical structures can have a considerable effect on system sensitivity, especially for systems processing multi-interaction photon events. This effect, however, does not impact the spatial resolution. Various mechanical structure designs are currently under evaluation in order to achieve optimum trade-off between temperature stability, accurate detector positioning, and minimum influence on system performance.

  15. 76 FR 59167 - Siemens Medical Solutions USA, Inc., Oncology Care Systems Division, Concord, CA; Siemens Medical...

    Science.gov (United States)

    2011-09-23

    ... Medical Solutions USA, Inc., Oncology Care Systems Division, Concord, CA; Siemens Medical Solutions USA... Solutions USA, Inc. (Siemens), Oncology Care Systems Division, Concord, California (subject firm). The...., Oncology Care Systems Division, Concord, California (TA-W-73,158) and Siemens Medical Solutions USA, Inc...

  16. PET

    DEFF Research Database (Denmark)

    Mariager, Rasmus Mølgaard; Schmidt, Regin; Heiberg, Morten Rievers

    PET handler om den hemmelige tjenestes arbejde under den kolde krig 1945-1989. Her fortæller Regin Schmidt, Rasmus Mariager og Morten Heiberg om de mest dramatiske og interessante sager fra PET's arkiv. PET er på flere måder en udemokratisk institution, der er sat til at vogte over demokratiet....... Dens virksomhed er skjult for offentligheden, den overvåger borgernes aktiviteter, og den registrerer følsomme personoplysninger. Historien om PET rejser spørgsmålet om, hvad man skal gøre, når befolkningen i et demokrati er kritisk indstillet over for overvågningen af lovlige politiske aktiviteter......, mens myndighederne mener, at det er nødvendigt for at beskytte demokratiet. PET er på en gang en fortælling om konkrete aktioner og begivenheder i PET's arbejde og et stykke Danmarkshistorie. Det handler om overvågning, spioner, politisk ekstremisme og international terrorisme.  ...

  17. Do carotid MR surface coils affect PET quantification in PET/MR imaging?

    International Nuclear Information System (INIS)

    Willemink, Martin J; Eldib, Mootaz; Leiner, Tim; Fayad, Zahi A; Mani, Venkatesh

    2015-01-01

    To evaluate the effect of surface coils for carotid MR imaging on PET quantification in a clinical simultaneous whole-body PET/MR scanner. A cylindrical phantom was filled with a homogeneous 2L water-FDG mixture at a starting dose of 301.2MBq. Clinical PET/MR and PET/CT systems were used to acquire PET-data without a coil (reference standard) and with two carotid MRI coils (Siemens Special Purpose 8-Channel and Machnet 4-Channel Phased Array). PET-signal attenuation was evaluated with Osirix using 51 (PET/MR) and 37 (PET/CT) circular ROIs. Mean and maximum standardized uptake values (SUVs) were quantified for each ROI. Furthermore, SUVs of PET/MR and PET/CT were compared. For validation, a patient was scanned with an injected dose of 407.7MBq on both a PET/CT and a PET/MR system without a coil and with both coils. PET/MR underestimations were -2.2% (Siemens) and -7.8% (Machnet) for SUVmean, and -1.2% (Siemens) and -3.3% (Machnet) for SUVmax, respectively. For PET/CT, underestimations were -1.3% (Siemens) and -1.4% (Machnet) for SUVmean and -0.5% (both Siemens and Machnet) for SUVmax, respectively using no coil data as reference. Except for PET/CT SUVmax values all differences were significant. SUVs differed significantly between PET/MR and PET/CT with SUVmean values of 0.51-0.55 for PET/MR and 0.68-0.69 for PET/CT, respectively. The patient examination showed that median SUVmean values measured in the carotid arteries decreased from 0.97 without a coil to 0.96 (Siemens) and 0.88 (Machnet). Carotid surface coils do affect attenuation correction in both PET/MR and PET/CT imaging. Furthermore, SUVs differed significantly between PET/MR and PET/CT.

  18. Automated radiochemical processing for clinical PET

    International Nuclear Information System (INIS)

    Padgett, H.C.; Schmidt, D.G.; Bida, G.T.; Wieland, B.W.; Pekrul, E.; Kingsbury, W.G.

    1991-01-01

    With the recent emergence of positron emission tomography (PET) as a viable clinical tool, there is a need for a convenient, cost-effective source of the positron emitter-labeled radiotracers labeled with carbon-11, nitrogen-13, oxygen-15, and fluorine-18. These short-lived radioisotopes are accelerator produced and thus, require a cyclotron and radiochemistry processing instrumentation that can be operated 3 in a clinical environment by competant technicians. The basic goal is to ensure safety and reliability while setting new standards for economy and ease of operation. The Siemens Radioisotope Delivery System (RDS 112) is a fully automated system dedicated to the production and delivery of positron-emitter labeled precursors and radiochemicals required to support a clinical PET imaging program. Thus, the entire RDS can be thought of as an automated radiochemical processing apparatus

  19. A basic study on lesion detectability for hot spot imaging of positron emitters with dedicated PET and positron coincidence gamma camera

    International Nuclear Information System (INIS)

    Zhang, Hong; Inoue, Tomio; Tian, Mei; Alyafei, Saleh; Oriuchi, Noboru; Khan, Nasim; Endo, Keigo; Li Sijin

    2001-01-01

    The aim of this study was to explore the correlations of detectability and the semi-quantification for hot spot imaging with positron emitters in positron emission tomography (PET) and with a positron coincidence detection system (PCD). Phantom study results for the measurement of the lesion-to-background (L/B) ratio ranged from 2.0 to 30.3, and detectability for hot spot lesion of PET and PCD were performed to correspond to clinical conditions. The detectability and semi-quantitative evaluation of hot spots from 4.4 mm to 36.9 mm in diameter were performed from the PET and PCD images. There were strong correlations between the L/B ratios derived from PET and PCD hot spot images and actual L/B ratios; but the L/B ratio derived from PET was higher than that from PCD with a significant difference of 10% to 54.8%. The detectability of hot spot imaging of PCD was lower than that of PET at 64.8% (PCD) versus 77.8% (PET). Even the actual L/B ratio was 8.0, hot spots more than 10.6 mm in diameter could be clearly identified with PCD imaging. The same identification could be achieved with PET imaging even when the actual L/B ratio was 4.0. This detailed investigation indicated that FDG PCD yielded results comparable to FDG PET on visual analysis and semi-quantitative analysis in detecting hot spots in phantoms, but semi-quantitative analysis of the L/B ratio with FDG PCD was inferior to that with FDG PET and the detectability of PCD in smaller hot spots was significantly poor. (author)

  20. Hybrid imaging for detection of carcinoma of unknown primary: A preliminary comparison trial of whole-body PET/MRI versus PET/CT

    International Nuclear Information System (INIS)

    Ruhlmann, Verena; Ruhlmann, Marcus; Bellendorf, Alexander; Grueneisen, Johannes; Sawicki, Lino M.; Grafe, Hong; Forsting, Michael; Bockisch, Andreas; Umutlu, Lale

    2016-01-01

    Highlights: • Both 18F-FDG PET/CT and 18F-FDG PET/MRI provide a comparable diagnostic ability for detection of primary cancer and metastases in CUP-syndrome. • Both imaging methods showed comparably high lesion conspicuity and diagnostic confidence (superior assessment of cervical lesions in PET/MRI). • PET/MRI may serve as a powerful alternative, particularly for therapy monitoring or surveillance considering the long-term cumulative dose. - Abstract: Purpose: The aim of this study is to evaluate and compare the diagnostic potential of integrated whole-body [18F]FDG-PET/MRI to [18F]FDG-PET/CT for detection of a potential primary cancer and metastases in patients suspected for cancer of unknown primary (CUP). Methods: A total of 20 patients (15 male, 5 female, age 53 ± 13 years) suspect for CUP underwent a dedicated head and neck & whole-body [18F]FDG-PET/CT (Biograph mCT 128, Siemens Healthcare) and a subsequent simultaneous [18F]FDG-PET/MRI examination (Biograph mMR, Siemens Healthcare). Two readers rated the datasets (PET/CT; PET/MRI) regarding the detection of the primary cancer and metastases, lesion conspicuity (4-point ordinal scale) and diagnostic confidence (3-point ordinal scale). PET analysis comprised the assessment of maximum standardized uptake values (SUVmax) of all PET-positive lesions using volume of interest (VOI) analysis derived from the PET/CT and PET/MR datasets. All available data considering histology and imaging including prior and clinical follow-up examinations served as reference standard. Statistical analysis included comparison of mean values using Mann-Whitney U test and correlation of SUVmax using Pearson‘s correlation. Results: In 14 out of 20 patients 49 malignant lesions were present. The primary cancer could be correctly identified in 11/20 patients with both PET/CT and PET/MRI. PET/CT enabled the detection of a total 38 metastases, PET/MR respectively of 37 metastases (one lung metastasis <5mm was missed). PET/CT and

  1. Hybrid imaging for detection of carcinoma of unknown primary: A preliminary comparison trial of whole-body PET/MRI versus PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Ruhlmann, Verena; Ruhlmann, Marcus; Bellendorf, Alexander [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Grueneisen, Johannes [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Sawicki, Lino M. [Department of Diagnostic and Interventional Radiology, University of Dusseldorf, Moorenstraße 5, 40225 Dusseldorf (Germany); Grafe, Hong [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Forsting, Michael [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Bockisch, Andreas [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Umutlu, Lale, E-mail: verena.ruhlmann@uk-essen.de [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany)

    2016-11-15

    Highlights: • Both 18F-FDG PET/CT and 18F-FDG PET/MRI provide a comparable diagnostic ability for detection of primary cancer and metastases in CUP-syndrome. • Both imaging methods showed comparably high lesion conspicuity and diagnostic confidence (superior assessment of cervical lesions in PET/MRI). • PET/MRI may serve as a powerful alternative, particularly for therapy monitoring or surveillance considering the long-term cumulative dose. - Abstract: Purpose: The aim of this study is to evaluate and compare the diagnostic potential of integrated whole-body [18F]FDG-PET/MRI to [18F]FDG-PET/CT for detection of a potential primary cancer and metastases in patients suspected for cancer of unknown primary (CUP). Methods: A total of 20 patients (15 male, 5 female, age 53 ± 13 years) suspect for CUP underwent a dedicated head and neck & whole-body [18F]FDG-PET/CT (Biograph mCT 128, Siemens Healthcare) and a subsequent simultaneous [18F]FDG-PET/MRI examination (Biograph mMR, Siemens Healthcare). Two readers rated the datasets (PET/CT; PET/MRI) regarding the detection of the primary cancer and metastases, lesion conspicuity (4-point ordinal scale) and diagnostic confidence (3-point ordinal scale). PET analysis comprised the assessment of maximum standardized uptake values (SUVmax) of all PET-positive lesions using volume of interest (VOI) analysis derived from the PET/CT and PET/MR datasets. All available data considering histology and imaging including prior and clinical follow-up examinations served as reference standard. Statistical analysis included comparison of mean values using Mann-Whitney U test and correlation of SUVmax using Pearson‘s correlation. Results: In 14 out of 20 patients 49 malignant lesions were present. The primary cancer could be correctly identified in 11/20 patients with both PET/CT and PET/MRI. PET/CT enabled the detection of a total 38 metastases, PET/MR respectively of 37 metastases (one lung metastasis <5mm was missed). PET/CT and

  2. 68Ga-PSMA and 11C-Choline comparison using a tri-modality PET/CT-MRI (3.0 T) system with a dedicated shuttle.

    Science.gov (United States)

    Alonso, Omar; Dos Santos, Gerardo; García Fontes, Margarita; Balter, Henia; Engler, Henry

    2018-01-01

    The aim of this study was to prospectively compare the detection rate of 68 Ga-PSMA versus 11 C-Choline in men with prostate cancer with biochemical recurrence and to demonstrate the added value of a tri-modality PET/CT-MRI system. We analysed 36 patients who underwent both 11 C-Choline PET/CT and 68 Ga-PSMA PET/CT scanning within a time window of 1-2 weeks. Additionally, for the 68 Ga-PSMA scan, we used a PET/CT-MRI (3.0 T) system with a dedicated shuttle, acquiring MRI images of the pelvis. Both scans were positive in 18 patients (50%) and negative in 8 patients (22%). Nine patients were positive with 68 Ga-PSMA alone (25%) and one with 11 C-Choline only (3%). The median detected lesion per patient was 2 for 68 Ga-PSMA (range 0-93) and 1 for 11 C-Choline (range 0-57). Tumour to background ratios in all concordant lesions ( n  = 96) were higher for 68 Ga-PSMA than for 11 C-Choline (110.3 ± 107.8 and 27.5 ± 17.1, mean ± S.D., for each tracer, respectively P  = 0.0001). The number of detected lesions per patient was higher for 11 C-Choline in those with PSA ≥ 3.3 ng/mL, while the number of detected lesions was independent of PSA levels for 68 Ga-PSMA using the same PSA cut-off value. Metastatic pelvic lesions were found in 25 patients (69%) with 68 Ga-PSMA PET/CT, in 18 (50%) with 11 C-Choline PET/CT and in 21 (58%) with MRI (3.0 T). MRI was very useful in detecting recurrence in cases classified as indeterminate by means of PET/CT alone at prostate bed. In patients with prostate cancer with biochemical recurrence 68 Ga-PSMA detected more lesions per patient than 11 C-Choline, regardless of PSA levels. PET/CT-MRI (3.0 T) system is a feasible imaging modality that potentially adds useful relevant information with increased accuracy of diagnosis.

  3. Nobel prize winners from Siemens company

    International Nuclear Information System (INIS)

    Anon

    2007-01-01

    This paper deals with the history of discoveries and scientists which worked in the Siemens company. First Nobel prize winners from Siemens company was Gustav Ludwig Hertz from Hamburg. In his doctoral dissertation he deals with the study of collisions of electrons with molecules of gases. In the physics this experiment is known as 'Franc and Hertz experiment', which confirmed state of energy in Bohr theory and in 1925 he obtained Nobel prize. In 1945, as a director of the Department of physics in the research laboratories of Siemens, he constructed cyclotron kernel - magnet with mass of 80 tonnes. The second Nobel prize winner was Dennis Gabor worked in the Laboratory for measurement and medicinal technology in Siemensstadt (Berlin). When he tried to increase the resolution of electron microscopy he discovered the holography (method of 3-dimensional imaging). In 1971 he obtained the Nobel prize. The third scientist - Ernst Ruska discovered electron microscope. At Siemens, he was involved in developing the first commercially-produced electron microscope in 1939. In 1986, Ernst Ruska was awarded half of the Nobel Prize in Physics for his many achievements in electron optics.

  4. Siemens tasks and activities during gradual upgrading

    International Nuclear Information System (INIS)

    Kuehne, B.

    2001-01-01

    The gradual upgrading of NPP V1 Bohunice constitutes the most extensive reconstruction project to be performed in an operational WWER plant to date. It constitutes a milestone in Siemens co-operation on projects for WWERs to date and is an encouraging example for the successful combination of western and eastern safety cultures. During the runtime of this project Siemens learnt very much about the 'complete function' as well as the details of this WWER plant type. In contrast the Slovakian partners really gained a much better understanding for the western approach to ensure safety, for the most modern safety technology, in particular for instrumentation and control, and last but not least or advanced project management. (author)

  5. First PET scans in Estonia

    International Nuclear Information System (INIS)

    Nazarenko, Sergei

    2003-01-01

    First PET scans in Estonia were performed on 25th November 2002 in North Estonia Regional Hospital, Tallinn. Six patients with melanoma underwent scanning with FDG. This event was a result of thorough extensive preparations first started in 2000 during the European Association of Nuclear Medicine congress in Paris. During the congress first contacts were made with providers of mobile PET units. At the same time negotiations were begun with potential FDG suppliers. For the introduction of PET in Estonia mobile truckmounted scanning technology was chosen due to low level of initial investments. Of particular importance was also availability of maintenance personnel from the device providers. A significant prerequisite was potential availability of FDG from the neighbourhood - Finland and Sweden. The latter avoided the necessity for investments into local cyclotrons and local FDG production. For the first scanning experience the dedicated truckmounted PET-camera Accel, Siemens was brought by the International Hospital Group (IHG, Amersfoort, Netherlands). The device arrived by ferry from Stockholm to Tallinn harbour at 10 o'clock in the morning and left by ferry for Helsinki at 23 o'clock. The team-on-truck consisted of one technician for device operation, two drivers and two company representatives. North Estonia Regional Hospital provided three additional technicians for patient preparation and FDG injection, one nuclear medicine doctor and one specialist of biomedical engineering and medical physics. The FDG was provided by MAP Medical Technologies, Schering, Helsinki, Finland. The shipments were made by air. This was possible due to small distance between Tallinn and Helsinki of approximately 80 km due to the regular flight connections between the two cities. The FDG was shipped in two lots with a time interval of 4 hours. The patient selection was based on clinical and histopathology data. In all six patients the exam was justified for detailied staging and

  6. Status of SOFC development at Siemens

    Energy Technology Data Exchange (ETDEWEB)

    Drenckhahn, W.; Blum, L.; Greiner, H. [Siemens AG, Erlangen (Germany)

    1996-12-31

    The Siemens SOFC development programme reached an important milestone in June 1995. A stack operating with hydrogen and oxygen produced a peak power of 10.7 kW at a current density of 0.7 A/cm{sup 2} and was running for more than 1400 hours. The SOFC configuration is based on a flat metal separator plate using the multiple cell array design. Improved PENs, functional layer and joining technique were implemented. Based on this concept, a 100 kW plant was designed The SOFC development at Siemens has been started in 1990 after a two years preparation phase. The first period with the goal of the demonstration of a 1 kW SOFC stack operation ended in 1993. This important milestone was finally reached in the begin of 1994. The second project phase with the final milestone of a 20 kW module operation will terminate at the end of 1996. This result will form a basis for the next phase in which a 50 to 100 kW pilot plant will be built and tested.

  7. IMPLEMENTATION DRIVERS FOR BPR AT SIEMENS TELECOMMUNICATIONS

    Directory of Open Access Journals (Sweden)

    C.C. Koorts

    2012-01-01

    Full Text Available

    ENGLISH ABSTRACT: With the embracing of neV'( management philosophies or redesigned processes, it is becoming a popular opinion that often the practical problem lies with the implementation of the new concept, rather than with the concept itself. By focussing on certain generic critical actions, chances of successful implementation increases for any new philosophy or re-engineered process. This article discusses such critical success actions, or implementation drivers as experience in a BPR project at Siemens Telecommunications.

    AFRIKAANSE OPSOMMING: 'n Gewilde siening ten opsigte van die bekendstelling van nuwe bestuursfilosofiee, of implementering van herontwerpde prosesse, is dat die probleem gewoonlik Ie by die implementering daarvan, eerder as by die beginsels van die bestuursfilosofie wat geimplementeer word . Deur op generies kritieke faktore te konsentreer, kan die kanse op suksesvolle implementering van bykans enige bestuursfilosofie of herontwerpde proses verbeter word. Hierdie artikel bespreek sulke kritieke sukses aksies, of implementeringsdrywers, aan die hand van 'n gevallestudie soos ervaar in 'n BPR projek by Siemens Telecommunications.

  8. Siemens: Smart Technologies for Large Control Systems

    CERN Multimedia

    CERN. Geneva; BAKANY, Elisabeth

    2015-01-01

    The CERN Large Hadron Collider (LHC) is known to be one of the most complex scientific machines ever built by mankind. Its correct functioning relies on the integration of a multitude of interdependent industrial control systems, which provide different and essential services to run and protect the accelerators and experiments. These systems have to deal with several millions of data points (e.g. sensors, actuators, configuration parameters, etc…) which need to be acquired, processed, archived and analysed. Since more than 20 years, CERN and Siemens have developed a strong collaboration to deal with the challenges for these large systems. The presentation will cover the current work on the SCADA (Supervisory Control and Data Acquisition) systems and Data Analytics Frameworks.

  9. Assessment of Siemens plessey electronic personal dosimeter

    International Nuclear Information System (INIS)

    Hirning, C.R.; Lopez, S.; Yuen, P.S.

    1994-01-01

    This report presents the results of a laboratory assessment of the performance of a new type of personal dosimeter. The Electronic Personal Dosimeter, or EPD, was developed jointly by the National Radiological Protection Board and Siemens Plessey Controls Limited, both of the United Kingdom. Twenty pre-production units of the EPD and a reader were purchased by Ontario Hydro for the assessment. The tests were conducted jointly by Ontario Hydro's Health and Safety Division and AECL Research's Chalk River Laboratories (CRL), with funding from the Candu Owner's Group. A total of 26 tests were conducted, divided between Ontario Hydro and AECL. The test results were compared with the relevant requirements of three standards. In general, the performance of the EPD was found to be quite acceptable. It met most of the relevant requirements of the three standards and most of the design specifications. However, the following deficiencies were found: slow response time; sensitivity to high-frequency EMF; poor resistance to dropping; and an alarm that is not loud enough. In addition, the response of the EPD to low-energy beta rays may be too low for some applications. There were serious problems with the reliability of operation of the pre production EPDs used in these tests. 9 refs., 34 tabs., 20 figs

  10. Assessment of Siemens plessey electronic personal dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Hirning, C R; Lopez, S [Ontario Hydro, Toronto, ON (Canada); Yuen, P S [Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.

    1994-01-01

    This report presents the results of a laboratory assessment of the performance of a new type of personal dosimeter. The Electronic Personal Dosimeter, or EPD, was developed jointly by the National Radiological Protection Board and Siemens Plessey Controls Limited, both of the United Kingdom. Twenty pre-production units of the EPD and a reader were purchased by Ontario Hydro for the assessment. The tests were conducted jointly by Ontario Hydro`s Health and Safety Division and AECL Research`s Chalk River Laboratories (CRL), with funding from the Candu Owner`s Group. A total of 26 tests were conducted, divided between Ontario Hydro and AECL. The test results were compared with the relevant requirements of three standards. In general, the performance of the EPD was found to be quite acceptable. It met most of the relevant requirements of the three standards and most of the design specifications. However, the following deficiencies were found: slow response time; sensitivity to high-frequency EMF; poor resistance to dropping; and an alarm that is not loud enough. In addition, the response of the EPD to low-energy beta rays may be too low for some applications. There were serious problems with the reliability of operation of the pre production EPDs used in these tests. 9 refs., 34 tabs., 20 figs.

  11. Siemens fuel gasification technology - solutions and developments

    Energy Technology Data Exchange (ETDEWEB)

    Hannemann, F.; Schingnitz, M.; Schmid, C. [Siemens Fuel Gasification Technology GmbH, Freiberg (Germany)

    2007-07-01

    In 2006, Siemens Power Generation Group acquired the GSP Gasification technology, and renamed it SFGT. The presentation reviews the technology and provides an update on current projects. The future plans for the development of the technology based on extensive experience and comprehensive development work gathered over many years and proven in a number of gasification plants is covered. SFGT operates, at its Freiberg facility, a 5 MWth pilot plant which was built to test prototype designs and to determine process conditions for various feed streams. An overview is given of the results of tests completed on a wide range of carbonaceous materials including all types of solid fuels from lignite to anthracite, as well as brown coal, oil, sludge or biomass, and low-temperature coke or petcoke. The technical focus of the paper is on the unique design features such as the cooling screen and alternative refractory lining, as well as the dense flow feeding system that allows the preferable use of lignite applications.

  12. Siemens IT solutions for power sector

    International Nuclear Information System (INIS)

    Lunter, P.

    2004-01-01

    The cost reduction, flexibility and revenue increase, potential exploitation, productivity increase, and business opportunities exploitation - that is all what can be required in the races for the promonent positioning on the electricity power market. These requirements can be realized by the sophisticated IT solutions hand-tailored to the special requirements of the electric power producers and tradesmen. This approach makes it possible to achieve greater profit. Our solutions 'PROFIT Solutions', that are symbiosis of the most progressive information technologies and the power plant techniques of the company Siemens, satisfy submitted specifications in substantial measure. The system solutions 'PROFIT Solutions' comprise three solution groups: process, operation a business. The solutions of the group 'IT Process Solutions' increase flexibility and manoeuvrability of equipment, improve the efficiency and contribute to more economical operation of the power generation. Solutions 'IT Process Solutions' simplify and shorten the period of power cycles and conduce to higher labour productivity. Solutions group 'IT Process Solutions' approaches equipment to the market - supports the profit strategies, helps quickly and expertly to determine and predict hazards. The extension PROFIT Cockpit means the nuance to the solutions world 'PROFIT Solutions'. The survey about the whole installation is within reach at the simple touch of a button. It is possible to compile the total system part by part from single solutions 'PROFIT Solutions'. As a matter of fact all single parts can be interconnected with already existing solutions. Routines 'PROFIT Solutions' cooperate with all modern control systems. (author)

  13. New Siemens applications for designing bevel gears

    Science.gov (United States)

    Goanta, A. M.; Dumitrache, P.

    2017-08-01

    The current situation in the design of gearings is different from software to software and in some cases requires specialized settings with or without additional costs. There are two ways of generating evolving tooting: one is based on the designer’s solid knowledge of geometry and gearing and the other is based on a series of automation subprograms for 3D modelling of gears. The first method is a general one, applicable to all design software that is based on generating a curve evolving specific to a tooth flank, continued with the construction of the symmetrical flank, the pattern multiplication of circular type around the center of the gear and finally generation of the three-dimensional characteristic of each individual tooth. The second method is much faster and requires only general knowledge about the gear but sufficiently advanced to allow permanent dialogue with the subprogram for generating cone gears. Absolute novelty items are brought about by the new NX design applications that lead to getting gears with curved teeth. In conclusion the paper shows how different variants of bevel gears are generated using various subprograms or performance settings, installed over the SIEMENS NX. An essential component of the paper is highlighting generation capacity of gears and gearing intended for predefined types of gear cutting machines such as those for Gleason and Oerlikon teeth.

  14. Cogeneration steam turbines from Siemens: New solutions

    Science.gov (United States)

    Kasilov, V. F.; Kholodkov, S. V.

    2017-03-01

    The Enhanced Platform system intended for the design and manufacture of Siemens AG turbines is presented. It combines organizational and production measures allowing the production of various types of steam-turbine units with a power of up to 250 MWel from standard components. The Enhanced Platform designs feature higher efficiency, improved reliability, better flexibility, longer overhaul intervals, and lower production costs. The design features of SST-700 and SST-900 steam turbines are outlined. The SST-700 turbine is used in backpressure steam-turbine units (STU) or as a high-pressure cylinder in a two-cylinder condensing turbine with steam reheat. The design of an SST-700 single-cylinder turbine with a casing without horizontal split featuring better flexibility of the turbine unit is presented. An SST-900 turbine can be used as a combined IP and LP cylinder (IPLPC) in steam-turbine or combined-cycle power units with steam reheat. The arrangements of a turbine unit based on a combination of SST-700 and SST-900 turbines or SST-500 and SST-800 turbines are presented. Examples of this combination include, respectively, PGU-410 combinedcycle units (CCU) with a condensing turbine and PGU-420 CCUs with a cogeneration turbine. The main equipment items of a PGU-410 CCU comprise an SGT5-4000F gas-turbine unit (GTU) and STU consisting of SST-700 and SST-900RH steam turbines. The steam-turbine section of a PGU-420 cogeneration power unit has a single-shaft turbine unit with two SST-800 turbines and one SST-500 turbine giving a power output of N el. STU = 150 MW under condensing conditions.

  15. Siemens technology transfer and cooperation in the nuclear fuel area

    International Nuclear Information System (INIS)

    Holley, H.-P.; Fuchs, J. H.; Rothenbuecher, R. A.

    1997-01-01

    Siemens is a full-range supplier in the area of nuclear power generation with broad experience and activities in the field of nuclear fuel. Siemens has developed advanced fuel technology for all types fuel assemblies used throughout the world and has significant experience worldwide in technology transfer in the field of nuclear fuel. Technology transfer and cooperation has ranged between the provision of mechanical design advice for a specific fuel design and the erection of complete fabrication plants for commercial operation in 3 countries. In the following the wide range of Siemens' technology transfer activities for both fuel design and fuel fabrication technologies are shown

  16. PET motion correction using PRESTO with ITK motion estimation

    Energy Technology Data Exchange (ETDEWEB)

    Botelho, Melissa [Institute of Biophysics and Biomedical Engineering, Science Faculty of University of Lisbon (Portugal); Caldeira, Liliana; Scheins, Juergen [Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich (Germany); Matela, Nuno [Institute of Biophysics and Biomedical Engineering, Science Faculty of University of Lisbon (Portugal); Kops, Elena Rota; Shah, N Jon [Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich (Germany)

    2014-07-29

    The Siemens BrainPET scanner is a hybrid MRI/PET system. PET images are prone to motion artefacts which degrade the image quality. Therefore, motion correction is essential. The library PRESTO converts motion-corrected LORs into highly accurate generic projection data [1], providing high-resolution PET images. ITK is an open-source software used for registering multidimensional data []. ITK provides motion estimation necessary to PRESTO.

  17. PET motion correction using PRESTO with ITK motion estimation

    International Nuclear Information System (INIS)

    Botelho, Melissa; Caldeira, Liliana; Scheins, Juergen; Matela, Nuno; Kops, Elena Rota; Shah, N Jon

    2014-01-01

    The Siemens BrainPET scanner is a hybrid MRI/PET system. PET images are prone to motion artefacts which degrade the image quality. Therefore, motion correction is essential. The library PRESTO converts motion-corrected LORs into highly accurate generic projection data [1], providing high-resolution PET images. ITK is an open-source software used for registering multidimensional data []. ITK provides motion estimation necessary to PRESTO.

  18. Siemens advance PWR fuel assemblies (HTP) and cladding

    International Nuclear Information System (INIS)

    Stout, R. B.; Woods, K. N.

    1997-01-01

    This paper describes the key features of the Siemens HTP (High Thermal Performance) fuel design, the current in-reactor performance of this advanced fuel assembly design, and the advanced cladding types available

  19. The Siemens pyrolysis-combustion process; Das Siemens Schwel-Brenn-Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, D. [Siemens - KWU, Offenbach (Germany)

    1996-12-31

    The market introduction fo the SIEMENS pyrolysis-combustion process is a technical and ecological milestone in thermal waste processing. It bridges the gap between conventional incineration and recycling and is ideally suited for the modern waste management philosophy. The innovative combination of pyrolysis followed by high-temperature combustion produces energy and reusable materials nearly without emissions. (orig/sr) [Deutsch] Die Markteinfuehrung des Schwel-Brenn-Verfahrens hat im Bereich der thermischen Muellentsorgung eine technologische und oekologische Zeitenwende eingeleitet. Es fuegt sich als Bruecke zwischen herkoemmlicher Muellverbrennung und stofflichem Muell-Recyling ideal in das Konzept einer oekologischen Kreislaufwirtschaft. Die innovative Kombination von Muellverschwelung (Pyrolyse) und anschliessender Hochtemperaturverbrennung wandelt den unvermeidbaren Restmuell nahezu rueckstandsfrei in Wertstoffe und Energie um. (orig/SR)

  20. The Siemens pyrolysis-combustion process; Das Siemens Schwel-Brenn-Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, D [Siemens - KWU, Offenbach (Germany)

    1997-12-31

    The market introduction fo the SIEMENS pyrolysis-combustion process is a technical and ecological milestone in thermal waste processing. It bridges the gap between conventional incineration and recycling and is ideally suited for the modern waste management philosophy. The innovative combination of pyrolysis followed by high-temperature combustion produces energy and reusable materials nearly without emissions. (orig/sr) [Deutsch] Die Markteinfuehrung des Schwel-Brenn-Verfahrens hat im Bereich der thermischen Muellentsorgung eine technologische und oekologische Zeitenwende eingeleitet. Es fuegt sich als Bruecke zwischen herkoemmlicher Muellverbrennung und stofflichem Muell-Recyling ideal in das Konzept einer oekologischen Kreislaufwirtschaft. Die innovative Kombination von Muellverschwelung (Pyrolyse) und anschliessender Hochtemperaturverbrennung wandelt den unvermeidbaren Restmuell nahezu rueckstandsfrei in Wertstoffe und Energie um. (orig/SR)

  1. Neuronal pathology in deep grey matter structures: a multimodal imaging analysis combining PET and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Bosque-Freeman, L.; Leroy, C.; Galanaud, D.; Sureau, F.; Assouad, R.; Tourbah, A.; Papeix, C.; Comtat, C.; Trebossen, R.; Lubetzki, C.; Delforge, J.; Bottlaender, M.; Stankoff, B. [Serv. Hosp. Frederic Joliot, Orsay (France)

    2009-07-01

    Objective: To assess neuronal damage in deep gray matter structures by positron emission tomography (PET) using [{sup 11}C]-flumazenil (FMZ), a specific central benzodiazepine receptor antagonist, and [{sup 18}F]-fluorodeoxyglucose (FDG), which reflects neuronal metabolism. To compare results obtained by PET and those with multimodal magnetic resonance imaging (MRI). Background: It is now accepted that neuronal injury plays a crucial role in the occurrence and progression of neurological disability in multiple sclerosis (MS). To date, available MRI techniques do not specifically assess neuronal damage, but early abnormalities, such as iron deposition or atrophy, have been described in deep gray matter structures. Whether those MRI modifications correspond to neuronal damage remains to be further investigated. Materials and methods: Nine healthy volunteers were compared to 10 progressive and 9 relapsing remitting (RR) MS patients. Each subject performed two PET examinations with [{sup 11}C]-FMZ and [{sup 18}F]-FDG, on a high resolution research tomograph dedicated to brain imaging (Siemens Medical Solution, spatial resolution of 2.5 mm). Deep gray matter regions were manually segmented on T1-weighted MR images with the mutual information algorithm (www.brainvisa.info), and co-registered with PET images. A multimodal MRI including T1 pre and post gadolinium, T2-proton density sequences, magnetization transfer, diffusion tensor, and protonic spectroscopy was also performed for each subject. Results: On PET with [{sup 11}C]-FMZ, there was a pronounced decrease in receptor density for RR patients in all deep gray matter structures investigated, whereas the density was unchanged or even increased in the same regions for progressive patients. Whether the different patterns between RR and progressive patients reflect distinct pathogenic mechanisms is currently investigated by comparing PET and multimodal MRI results. Conclusion: Combination of PET and multimodal MR imaging

  2. Siemens's spectrum of deliveries and services for nuclear power plants

    International Nuclear Information System (INIS)

    2011-01-01

    In 2001, Siemens and Framatome merged their nuclear activities in the present Areva NP joint venture. Siemens has since focused on the construction and further development of conventional power plants and on the so-called conventional island (CI), the non-nuclear part of a nuclear power plant, i.e. the steam turbine, generator, and plant I and C systems, and also on service for the conventional part of nuclear power plants. Its role as a minority shareholder in Areva NP constrained Siemens. For this reason, the company in January 2009 decided to terminate its interest in Areva NP effective January 30, 2012. By January 2012 at the latest, Siemens will transfer to the majority shareholder Areva, holding 66 percent of the shares, its interest in the joint venture. For the time being, the joint venture still entails certain limitations to Siemens's activities in the nuclear field. Its delivery of the conventional island for the Olkiluoto 3 (OL3) nuclear power plant in Finland confirms the company's know-how in power plant construction. When commissioned, its 1,720 MW power will make OL3 the world's largest nuclear generating unit. The turbo-generator of the CI comprises a double-flow HP turbine and a 6-flow LP turbine. The driven 4-pole generator with a power of up to 2,200 MVA consists of a water-cooled stator and a hydrogen-cooled rotor. (orig.)

  3. Experience with PET FDG - Preliminary analysis

    International Nuclear Information System (INIS)

    Massardo, Teresa; Jofre, Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Galaz, Rodrigo; Miranda, Karina

    2004-01-01

    Full text: The objective of this preliminary communication was to analyse the indications and data in initial group of patients studied with first dedicated PET scanner in the country at Hospital Militar in Santiago Chile. The main application of positron emission tomography (PET) with 18-Fluoro deoxyglucose (FDG) is related with oncological patients management. We studied 136 patients, 131 (97%) with known or suspected malignant disease and remaining 5 for cardiological or neuropsychiatric disease. Ten patients were controlled diabetics (1 insulin dependent). Their mean age was 51.6±18 years ranging from 6 to 84 years and 65% were females. A total of 177 scans were acquired using a dedicated PET (Siemens HR + with 4mm resolution) system. Mean F18-FDG injected dose was 477±107 MBq (12.9±2.9 mCi). Mean blood glucose levels, performed prior the injection, were 94±17mg/dl (range 62-161). F18-FDG was obtained from the cyclotron IBA Cyclone 18/9 installed in the Chilean Agency of Nuclear Energy, distant about 15 miles away from the clinical PET facility. PET studies were analyzed by at least 4 independent observers visually. Standardized uptake value (SUV) was calculated in some cases. Image fusion of FDG images with recent anatomical (CT, MRI) studies was performed where available. Data acquisition protocol consisted in 7-8 beds/study from head to mid-thighs, with 6-7-min/bed acquisitions, 36% transmission with germanium 68 rods. Data was reconstructed with standard OSEM protocol. The main indications included pulmonary lesions in 31%, gastrointestinal cancers in 21%, melanoma in 13% and lymphoma in 9% patients. The remaining were of breast, thyroid, testes, ovary, musculoskeletal (soft tissue and bone), brain tumour etc. Abnormal focal tracer uptake was observed in 83/131 oncological patients, 54% corroborating with clinical diagnosis of primary tumor or recurrence while 46% showed new metastatic localization. FDG scans were normal 36/131 patients. In 9 patients

  4. Experience with PET FDG - Preliminary analysis

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa; Jofre, Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Galaz, Rodrigo; Miranda, Karina [Centro PET de Imagenes Moleculares, Hospital Militar de Santiago, Santiago (Chile)

    2004-01-01

    Full text: The objective of this preliminary communication was to analyse the indications and data in initial group of patients studied with first dedicated PET scanner in the country at Hospital Militar in Santiago Chile. The main application of positron emission tomography (PET) with 18-Fluoro deoxyglucose (FDG) is related with oncological patients management. We studied 136 patients, 131 (97%) with known or suspected malignant disease and remaining 5 for cardiological or neuropsychiatric disease. Ten patients were controlled diabetics (1 insulin dependent). Their mean age was 51.6{+-}18 years ranging from 6 to 84 years and 65% were females. A total of 177 scans were acquired using a dedicated PET (Siemens HR + with 4mm resolution) system. Mean F18-FDG injected dose was 477{+-}107 MBq (12.9{+-}2.9 mCi). Mean blood glucose levels, performed prior the injection, were 94{+-}17mg/dl (range 62-161). F18-FDG was obtained from the cyclotron IBA Cyclone 18/9 installed in the Chilean Agency of Nuclear Energy, distant about 15 miles away from the clinical PET facility. PET studies were analyzed by at least 4 independent observers visually. Standardized uptake value (SUV) was calculated in some cases. Image fusion of FDG images with recent anatomical (CT, MRI) studies was performed where available. Data acquisition protocol consisted in 7-8 beds/study from head to mid-thighs, with 6-7-min/bed acquisitions, 36% transmission with germanium 68 rods. Data was reconstructed with standard OSEM protocol. The main indications included pulmonary lesions in 31%, gastrointestinal cancers in 21%, melanoma in 13% and lymphoma in 9% patients. The remaining were of breast, thyroid, testes, ovary, musculoskeletal (soft tissue and bone), brain tumour etc. Abnormal focal tracer uptake was observed in 83/131 oncological patients, 54% corroborating with clinical diagnosis of primary tumor or recurrence while 46% showed new metastatic localization. FDG scans were normal 36/131 patients. In 9

  5. Christ-Siemens-Touraine syndrome with cleft palate, absent nipples ...

    African Journals Online (AJOL)

    We report a 6 year old child, second in order of birth of non consanguineous Egyptian parents with typical characteristics of Christ-Siemens-Touraine syndrome. The patient had sparse light hair over the scalp, scanty eyebrows and eyelashes, a high arched cleft palate, decayed oligodontic teeth, hyperpigmentation all over ...

  6. 18FDG PET scanning of benign and malignant musculoskeletal lesions

    International Nuclear Information System (INIS)

    Feldman, Frieda; Heertum, Ronald van; Manos, Chitra

    2003-01-01

    To describe the technique, applications and advantages of 18 FDG PET scanning in detection, analysis and management of musculoskeletal lesions.Design and patients Forty-five patients (19 males,26 females) aged 9 to 81 years had radiographs, routine radionuclide scans, CT and/or MRI of clinically suspected active benign or malignant musculoskeletal lesions. 18 FDG scans with a Siemens ECAT EXACT 921 dedicated PET unit (Knoxville, Tenn.) and FWH=6 mm images acquired as a 5-6 bed examination (6 min emission and 4 min transmission) used OSEM iterative reconstruction with segmented transmission attenuation correction and a Gaussian filter (cutoff 6.7 mm). Region of interest (ROI) 3 x 3 pixel image analysis based on transverse whole body images (slice thickness 3.37 mm) generated Maximum Standard Uptake Values (Max SUV) with a cutoff of 2.0 used to distinguish benign and malignant lesions. Thirty-nine studies were available for SUV ROI analysis. Overall sensitivity for differentiating malignant from benign osseous and non-osseous lesions was 91.7% (22/24), overall specificity was 100% (11/11) with an accuracy of 91.7%. All aggressive lesions had a Max SUV >2.0. Data separating benign from malignant lesions and aggressive from benign lesions were statistically significant (P 18 FDG PET contributes unique information regarding metabolism of musculoskeletal lesions. By supplying a physiologic basis for more informed treatment and management, it influences prognosis and survival. Moreover, since residual, recurrent or metastatic tumors can be simultaneously documented on a single whole body scan, PET may theoretically prove to be cost-effective. (orig.)

  7. 18-FDG-PET in pretherapeutical determination of extra medullary involvement prior to Re-188-antibody guided myeloablative therapy

    International Nuclear Information System (INIS)

    Hofmann, M.; Boerner, A.R.; Otto, D.; Knapp, W.H.; Hertenstein, B.

    2002-01-01

    Full text: In relapsed or refractory leukemia it is highly desirable to intensify the conditioning prior to allogenic bone mamarrow transplantation (BMT). Application of the 188-Re-labelled antibody BW 250/183 has proved to be feasible for internal radiation therapy of the bone marrow. Because the number of granulocytes (which express the CD66b antigen targeted) in extramedullary manifestations are usually low, the treatment of extramkedullary lesions will be not effective. This study deals with the pretherapeutical identification of patients with extramedullary involvement via 18-F-FDG-PET. 1-2 weeks prior scheduled 188-Re-therapy 12 patients underwent 18-F-FDG PET (dedicated PET scanner Siemens ECAT EXACT 47). Non physiological tracer accumulations were evaluated by means of SUV and consecutive morphological imaging (CT/MRI). 3 of 11 patients did show non physiological enrichment. 1 patient had enrichment in the upper mediastine, which was confirmed as extramedullary leukemia involvement by cytology. In CT scan these lesions had been identified as small lymphnodes (1-2 cm diameter). 2 Patients did show small lesions in the lung. In one patient they were confirmed to be active fungous infection (pos. sputum culture) and in the other patient they were regarded as regenerative residuals of previous known pneumonic infection not active now (neg. sputum cultures and neg. inflammation markers). 18-F-FDG PET is helpful of identifying extramedullary involvement and gives in addition information on the inflammatory status of patients prior to BMT. (author)

  8. Musculoskeletal MRI: dedicated systems

    International Nuclear Information System (INIS)

    Masciocchi, C.; Barile, A.; Satragno, L.

    2000-01-01

    The ''dedicated'' MRI units have characteristics of high diagnostic accuracy and lower installation and management costs as compared with whole-body systems. The dedicated MRI units are easy to install. The low weight allows their installation also under unfavorable circumstances. In a dedicated system cost-effectiveness and ease of installation must be accompanied by the capability of providing high-quality images. In our experience, the high number of examinations performed, the most part of which provided with the surgical controls, allowed an accurate evaluation of the diagnostic potentialities of the dedicated magnet. We were not able to perform the examinations in only 3 % of cases due to the physical shape of the patient and the clinical condition of the patient which may hinder the correct positioning of the limb. The overlapping of the diagnostic accuracy of the E-scan and Artoscan units in the study of the lower limbs, compared with whole-body units and surgery, prompted us to exploit the potentialities of the E-Scan in the study of the shoulder. We had a good correlation between E-Scan, whole-body units, and surgical findings, which confirmed the high diagnostic accuracy of the dedicated system. In conclusion, in our experience carried out in the musculoskeletal system, the dedicated magnets showed promising results. Their diagnostic reliability and utility was comparable to that obtained from conventional units operating at higher magnetic fields. (orig.)

  9. Intraindividual comparison of F-18-FLT PET and F-18 FET PET in brain tumor patients

    International Nuclear Information System (INIS)

    Kim, Sung Eun; Cheon, G. J.; Cho, Y. S.; Kwak, H. S.; Lee, C. H.; Choi, C. W.; Lim, S. M.

    2003-01-01

    To compare findings on FLT PET with FET PET, we prospectively undertaken FLT, FET and FDG PET in same patient with suspected primary/metastatic and recurrent brain tumors. Seventeen studies in 16 patients (47 8.3 years, M: F 10: 6) with brain tumor (3 for initial diagnosis, 6 for therapeutic response, 6 for detecting recurrence, 1 for diagnosis and recurrence both) were included. Brain tumors were 14 gliomas (6 high- grade 9 low-grade by the WHO classification), 2 metastatic brain tumors and 1 CNS lymphoma. 18F-FDG, FLT and FET PET were performed within two weeks. Attenuation-corrected brain images were acquired 30 minutes after injection of 370-555 MBq FDG, FLT and FET with a dedicated PET scanner (ECAT HR scanner, Siemens-CTI). Maximum SUV (max SUV) and relative uptake defined by FLT and FET accumulation within the tumor in relation to a contralateral control region (max SUV for tumor/ mean SUV for contralateral normal gray matter) were calculated. 26 tumor foci were analyzed. Relative FLT uptake (4.17 2.4, 0.58 to 7.45) was grater than than FET uptake (2.03 1.17, 0.92 to 4.53 (p<0.0006)) and FDG uptake (1.16 0.34, 0.76 to 2.08). Among FLT, FET and FDG uptakes in 20 tumor foci, correlation were poor. the relative FLT uptake of high-grade glioma was higher than low-glioma (6.070.76 vs 3.11 2.15, p=0.002), however, relative FET uptake was not different significantly (2.68 1.51, high-grade vs 1.970.78, low-grade). The correlation between tumor grade (high vs low grade) and relative uptake (FLT and FET) was shown only with relative FLT uptake (r=0.62, p=0.002). The best cut off value of relative FLT uptake between high-grade and low-grade glioma was 4.54 (AUC: 0.89 sensitivity: 100 specificity: 86.7%). Compared with FET uptake, FLT uptake showed much higher contrast and associated with tumor grade. Further study, evaluation of proliferative index of Ki-67 and its relationship with FLT and FET uptake, are ongoing

  10. Performance characteristics of ZLC 37 Siemens gamma camera

    International Nuclear Information System (INIS)

    Abdelgadir, Wafaa Abdelrahman

    1994-04-01

    The relationships between the ZLC 37 Siemens γ camera parameters (energy resolution, plane sensitivity, intrinsic uniformity, intrinsic resolution, system uniformity and system resolution) and diagnostic imaging performance was investigated. These parameters when computers when compared with internationally published data showed that the ZLC 37 Siemens γ cameras is in good operative conditions. The effect of the scattering media and WW on the spatial resolution, when the distance is kept fixed were investigated. Comparison of resolution for the media (air, water, water + radioactivity when using WW (10, 15,20%) showed that the resolution is best for air, better for water and worse for water + radioactivity up to a concentration of 8% for a 10% WW. (Author)

  11. Performance characteristics of ZLC 37 Siemens gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Abdelgadir, Wafaa Abdelrahman [Department of Physics, Faculty of Science, University of Khartoum, Khartoum (Sudan)

    1994-04-01

    The relationships between the ZLC 37 Siemens {gamma} camera parameters (energy resolution, plane sensitivity, intrinsic uniformity, intrinsic resolution, system uniformity and system resolution) and diagnostic imaging performance was investigated. These parameters when computers when compared with internationally published data showed that the ZLC 37 Siemens {gamma} cameras is in good operative conditions. The effect of the scattering media and WW on the spatial resolution, when the distance is kept fixed were investigated. Comparison of resolution for the media (air, water, water + radioactivity) when using WW (10, 15,20%) showed that the resolution is best for air, better for water and worse for water + radioactivity up to a concentration of 8% for a 10% WW. (Author) 28 refs. , 10 tabs. , 22 figs. Also available from the Department of Physics, Faculty of Science, University of Khartoum, Khartoum (SD)

  12. Siemens capabilities to perform detailed fuel inspections during short outages

    International Nuclear Information System (INIS)

    Knecht, K.; Reparaz, A.

    1999-01-01

    Fuel inspection data are used to support development activities such as corrosion resistant cladding and advanced fuel assembly designs that will reach higher burnups. Increased inspection efforts are necessary to optimize fuel management and performance strategies. Additionally, there is an increasing trend to reduce outage time in Germany and abroad. Siemens has recently developed several timesaving systems for rapid inspection of fuel assemblies and core components. Siemens' focus in developing these systems has been to obtain data in reduced reactor outage time while increasing both the volume and the quality of the measured data. Mast sipping for PWRs is used for identifying leaking fuel assemblies and allows early detection of leaks during downloading of the fuel assemblies from the reactor. An In-Core sipping system for BWRs based on a hood technique to allow testing a full core within 16 hours is under development. (authors)

  13. Implementation of Siemens USS protocol into LabVIEW.

    Science.gov (United States)

    Hosek, P; Diblik, M

    2011-10-01

    This article gives basic overview of the USS protocol as a communication interface to drive Siemens frequency inverters. It presents our implementation of this protocol into LabVIEW, as there was permanent demand from the community of the users to have native LabVIEW implementation of the USS protocol. It also states encountered problems and their solutions. Copyright © 2011 Society for Laboratory Automation and Screening. Published by Elsevier Inc. All rights reserved.

  14. Quality assurance for MR stereotactic imaging for three Siemens scanners

    International Nuclear Information System (INIS)

    Kozubikova, P.; Novotny, J. Jr.; Kulhova, K.; Mihalova, P.; Tamasova, J.; Veselsk, T.

    2014-01-01

    Quality assurance of stereotactic imaging, especially with MRI (magnetic resonance imaging), is a complex issue. It can be divided in the basic verification and commissioning of a particular new scanner or a new scanning MRI protocol that is being implemented into a clinical practice and the routine quality assurance performed for each single radiosurgical case. The aim of this study was geometric distortion assessment in MRI with a special PTGR (Physikalisch-Technische Gesellschaft fuer Radiologie - GmbH, Tuebingen, Germany) target phantom. PTGR phantom consists of 21 three-dimensional cross-hairs filled with contrast medium. Cross hairs are positioned at known Leksell coordinates with a precision of better than 0.1 mm and covering the whole stereotactic space. The phantom can be fixed in the Leksell stereotactic frame and thus stereotactic imaging procedures can be reproduced following exactly the same steps as for a real patient, including also the stereotactic image definition in the Leksell GammaPlan. Since the geometric position (stereotactic coordinates) of each cross-hair is known based on the construction of the phantom, it can be compared with the actual measured Leksell coordinates based on the stereotactic MRI. Deviations between expected and actual coordinates provide information about the level of distortion. The measured distortions proved satisfactory accuracy precision for stereotactic localization at 1.5 T Siemens Magnetom Avanto scanner, Siemens Magnetom Symphony scanner and 3T Siemens Magnetom Skyra scanner (Na Homolce Hospital, Prague). The mean distortion for these MR scanners for standard imaging protocol (T1 weighted 3D images) were 0.8 mm, 1.1 mm and 1.1 mm and maximum distortions were 1.3 mm, 1.9 mm and 2.2 mm, respectively.There was detected dependence of the distortions on the slice orientation and the type of imaging protocol. Image distortions are also property of each particular scanner, the worst distortion were observed for 3T

  15. Combined PET/MRI

    DEFF Research Database (Denmark)

    Bailey, D. L.; Pichler, B. J.; Gückel, B.

    2015-01-01

    This paper summarises key themes and discussions from the 4th international workshop dedicated to the advancement of the technical, scientific and clinical applications of combined positron emission tomography (PET)/magnetic resonance imaging (MRI) systems that was held in Tübingen, Germany, from...

  16. Hyperbolic projections of siemens 3d-mlc leaf paths

    International Nuclear Information System (INIS)

    Menzies, N.

    2004-01-01

    Full text: The Siemens Primus linear accelerator has the option of being fitted with a multi-leaf collimator (3D-MLC) that is marketed as having 'double focus', to achieve a constant dose penumbra for all leaf settings. This is achieved by moving the leaves through arcs (similar to some conventional collimator jaws), as well as shaping the leaf side-faces as divergent planes from the x-ray source. One consequence of the mechanical design of the 3D-MLC is that as individual leaves are moved, their projections from the light / x-ray source to the treatment plane follow paths that are hyperbolic, as shown in the figure below. (The eccentricity of the hyperbola is a function of leaf number / distance from centre.) The trajectories of the MLC leaves were modelled (in a spreadsheet) using geometrical projections of the MLC leaves to the treatment plane, with construction details provided in Siemens documentation. The results were checked against the image of the leaf in the linac light field. This problem belongs to the class of conic sections in mathematics, where the intersection of a plane with both nappes of a double right circular cone results in a hyperbola. The good agreement between the model and the light field image provided confirmation of the MLC construction details. AS/NZS 4434.1:1996 (reproduced from IEC 976:1989) provides specifications for maximum deviation from orthogonality of adjacent edges, which can be interpreted for MLC collimators to parallelism of the direction of leaf travel and the adjacent collimator edge (e.g. Elekta ATS). However for the Siemens 'double focused' MLC, it is demonstrated that the geometrical construction of the MLC militates against the leaf image being used for this kind of test. It is also demonstrated that at last one commercial treatment planning system models the Siemens leaf trajectories linearly. The clinical significance of the error in this model is shown to be negligible. Copyright (2004) Australasian College of

  17. NPI one year on [Framatome-Siemens common product

    International Nuclear Information System (INIS)

    Ruess, F.; Lebreton, G.

    1990-01-01

    Nuclear Power International (NPI), a joint subsidiary of Framatome and Siemens was established in April 1989 to coordinate the development and marketing of a common PWR technology for the world market. Both parent companies command well proven PWR technology and can rely on experience gained with over 100 000MWe of nuclear capacity in operation, under construction or on order. The technology from each is being offered through NPI until the joint PWR technology which is under development, becomes available. NPI's experience to date is reviewed. (author)

  18. Dedicated bifurcation stents

    Directory of Open Access Journals (Sweden)

    Ajith Ananthakrishna Pillai

    2012-03-01

    Full Text Available Bifurcation percutaneous coronary intervention (PCI is still a difficult call for the interventionist despite advancements in the instrumentation, technical skill and the imaging modalities. With major cardiac events relate to the side-branch (SB compromise, the concept and practice of dedicated bifurcation stents seems exciting. Several designs of such dedicated stents are currently undergoing trials. This novel concept and pristine technology offers new hope notwithstanding the fact that we need to go a long way in widespread acceptance and practice of these gadgets. Some of these designs even though looks enterprising, the mere complex delivering technique and the demanding knowledge of the exact coronary anatomy makes their routine use challenging.

  19. Dedicating Fermilab's Collider

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1986-01-15

    It was a bold move to have a fullscale dedication ceremony for the new proton-antiproton Collider at the Fermilab Tevatron on 13 October, two days before the first collisions were seen. However the particles dutifully behaved as required, and over the following weekend the Collider delivered its goods at a total energy of 1600 GeV, significantly boosting the world record for laboratory collisions.

  20. PET/MRI for Preoperative Planning in Patients with Soft Tissue Sarcoma

    DEFF Research Database (Denmark)

    Loft Jakobsen, Annika; Jensen, Karl Erik; L�fgren, Johan

    2013-01-01

    Clinical positron emission tomography (PET)/magnetic resonance imaging (MRI) acquisition protocols may improve the evaluation of soft tissue sarcomas (STS) prior to surgical planning. We examined two patients with lower extremity STS using a Siemens Biograph mMR PET/MRI scanner and the glucose...

  1. The usefulness of the combined PET-CT scanner

    International Nuclear Information System (INIS)

    Yoshikawa, Kyosan

    2003-01-01

    Recently, combined PET-CT scanners that simultaneously reveal both anatomical and metabolic images within the body have been developed. The Siemens Biograph was the first PET-CT used in Japan and was installed at National Institute of Radiological Sciences (NIRS) at the end of March 2002. The Biograph system integrates Siemens PET (HR+) and spiral CT (SOMATOM Emotion Duo) technologies with a multimodality computer platform. The CT data obtained with PET-CT is also used for attenuation corrections of the PET images. The advantages of PET-CT for clinical use are much shorter study time for each patient, easy and precise alignment of the patient's lesion within the PET field of view, an increase in PET image quality due to the CT attenuation correction system which gives a higher spatial resolution and produces much less noise in the attenuation correction data, and an improvement in diagnostic accuracy provided by both functional and anatomic imaging. The Japanese government has not yet approved the marketing of PET-CT. We are continuing to investigate its usefulness. We expect that PET-CT will be a major diagnostic tool for oncology imaging in the near future. (authors)

  2. Activities of the KWU training centre of SIEMENS at Karlstein

    International Nuclear Information System (INIS)

    Gronau, D.; Guettner, K.

    1996-01-01

    Siemens as turnkey supplier of nuclear and fossil power plants recognized at an early stage that besides commissioning of the plants, also the instruction and good training of the operational and the maintenance personnel is a necessary condition for safe operation of all systems and a high plant availability. Therefore it was decided to provide a KWU Training Centre of the Siemens AG being located at Karlstein/Main near the historical town Seligenstadt, about 45 km from Frankfurt airport. The advantage of this location is connected with the other activities in this place for example: central base for reactor service, including a training area with a steam generator mock-up for optimizing corresponding maintenance and repair work; technological centre for radioactive waste and contaminated components; manufacturing activities, especially in-core instrumentation; component test laboratory, especially large valve test facility; post-irradiation investigations in materials and chemical laboratories; simulator design and development. All these activities have connections to the plant operation and maintenance and can therefore reasonably be integrated in practically oriented training measures for different categories of plant personnel. 7 figs

  3. Siemens fuel gasification technology for the Canadian oil sands industry

    Energy Technology Data Exchange (ETDEWEB)

    Morehead, H. [Siemens Energy Inc., Orlando, FL (United States). IGCC and Gasification Sales and Marketing

    2010-07-01

    The Siemens fuel gasification (SFG) technology can be used to gasify a range of feedstocks, including petcoke, hard coal, lignite, and low-ranking fuels such as biomass and refinery residuals. The technology has recently been applied to a number of projects over the last 3 years. This paper discussed some of the issues related to the technology and it's use at a start-up facility in China. Five entrained-flow gasifiers with a thermal capacity of 500 MW are being installed at a coal gasification plant in northwestern China. The technology's use in hydrogen, steam and power production applications for the oil sands industry was also discussed. Issues related to feedstock quality, process characteristics, and equipment requirements for commercial gasifier systems were reviewed. The paper concluded by observing that improvements in gasification technology will make coal and petcoke gasification feasible options for power generation. IGCC is the most advanced and cost-effective technology for reducing emissions from coal-fired power plants. Gasification-based plants are also able to capture carbon dioxide (CO{sub 2}) for storage and sequestration. Details of the Siemens gasification test center in Germany were also included. 1 tab., 4 figs.

  4. Ichthyosis bullosa of Siemens: Response to topical tazarotene

    Directory of Open Access Journals (Sweden)

    Rajiv S

    2006-01-01

    Full Text Available In 1937, Siemens described a Dutch family with superficial blistering, flexural hyperkeratosis, and characteristic mauserung appearance. Since then, less than 20 kindreds with this condition have been described in the English dermatologic literature. A 14-year-old boy presented with history of recurrent blistering and peeling of skin since the age of 1 month, predominantly seen over limbs and trunk, often associated with secondary infection. His mother also had similar symptoms from childhood. On examination, the child had typical mauserung peeling of the skin and dirty gray hyperkeratosis in a rippled pattern over flexures. Skin biopsy from the boy showed intracorneal blistering with epidermolytic hyperkeratosis in the upper spinous layers. The typical history and clinical features along with characteristic histological findings confirmed our diagnosis of ichthyosis bullosa of Siemens. It must be differentiated from other conditions with epidermolytic hyperkeratosis and skin peeling, such as bullous ichthyosiform erythroderma of Brocq and peeling skin syndrome. Our patient responded well to 0.05% topical tazarotene gel over four weeks.

  5. Checking the virtual treatment modality Wedge from Siemens; Verificacion de la modalidad de tratamiento virtual WEDGE de SIEMENS

    Energy Technology Data Exchange (ETDEWEB)

    Suero Rodrigo, M. A.; Marques Fraguela, E.

    2011-07-01

    The treatment modality Virtual Wedge (VW) or implemented by Siemens virtual wedge in electron linear accelerators achieved dose distributions are similar but not identical, to those obtained with physical wedges. Among the advantages against the latter is the greater ease of use, wedge factor close to one, and lower peripheral dose. However, these benefits are to be effective requires a through quality control dependence because a larger number of parameters that control the generation of the beam, the dose monitor system and the movement of the jaws of the collimator. We performed a study of the wedge taking into account different configurations that can affect their behavior from the dosimetric point of view.

  6. Whole-body PET/MRI: The effect of bone attenuation during MR-based attenuation correction in oncology imaging

    Energy Technology Data Exchange (ETDEWEB)

    Aznar, M.C., E-mail: marianne.aznar@regionh.dk [Department of Oncology, Section of Radiotherapy 3994, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen (Denmark); Sersar, R., E-mail: rachidadk@hotmail.com [DTU Informatics, Technical University of Denmark, Kongens Lyngby (Denmark); Saabye, J., E-mail: julie_saa@hotmail.com [DTU Informatics, Technical University of Denmark, Kongens Lyngby (Denmark); Ladefoged, C.N., E-mail: claesnl@gmail.com [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Andersen, F.L., E-mail: Flemming.Andersen@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Rasmussen, J.H., E-mail: jacobrasmu@gmail.com [Department of Oncology, Section of Radiotherapy 3994, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen (Denmark); Löfgren, J., E-mail: Johan.Loefgren@regionh.dk [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Beyer, T., E-mail: thomas.beyer@meduniwien.ac.at [Centre for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna (Austria)

    2014-07-15

    Purpose: In combined PET/MRI standard PET attenuation correction (AC) is based on tissue segmentation following dedicated MR sequencing and, typically, bone tissue is not represented. We evaluate PET quantification in whole-body (WB)-PET/MRI following MR-AC without considering bone attenuation and then investigate different strategies to account for bone tissue in clinical PET/MR imaging. To this purpose, bone tissue representation was extracted from separate CT images, and different bone representations were simulated from hypothetically derived MR-based bone classifications. Methods: Twenty oncology patients referred for a PET/CT were injected with either [18F]-FDG or [18F]-NaF and imaged on PET/CT (Biograph TruePoint/mCT, Siemens) and PET/MRI (mMR, Siemens) following a standard single-injection, dual-imaging clinical WB-protocol. Routine MR-AC was based on in-/opposed-phase MR imaging (orgMR-AC). PET(/MRI) images were reconstructed (AW-OSEM, 3 iterations, 21 subsets, 4 mm Gaussian) following routine MR-AC and MR-AC based on four modified attenuation maps. These modified attenuation maps were created for each patient by non-linear co-registration of the CT images to the orgMR-AC images, and adding CT bone mask values representing cortical bone: 1200 HU (cortCT), spongiosa bone: 350 HU (spongCT), average CT value (meanCT) and original CT values (orgCT). Relative difference images of the PET following AC using the modified attenuation maps were compared. SUVmean was calculated in anatomical reference regions and for PET-positive lesions. Results: The relative differences in SUVmean across patients following orgMR-AC and orgCT in soft tissue lesions and in bone lesions were similar (range: 0.0% to −22.5%), with an average underestimation of SUVmean of 7.2% and 10.0%, respectively when using orgMR-AC. In bone lesions, spongCT values were closest to orgCT (median bias of 1.3%, range: –9.0% to 13.5%) while the overestimation of SUVmean with respect to orgCT was

  7. Editors note, and Dedication

    Directory of Open Access Journals (Sweden)

    Laura Mugnai

    2011-12-01

    Full Text Available This Supplement to volume 50 of Phytopathologia Mediterranea contains original, peer reviewed research papers, prepared from presentations at the 7th International Workshop on Grapevine Trunk Diseases (IWGTD. This Workshop was held in Santa Cruz, Chile, 17–21 January 2010, and was organized by the International Council on Grapevine Trunk Diseases (ICGTD.  Publication of this Supplement has been financially assisted by the International Society for Plant Pathology (ISPP.This Supplementary Issue of Phytopathologia Mediterranea is dedicated to the memory of Dr Luigi Chiarappa, the founder and inspiration of the ICGTD.  

  8. Effect of MR contrast agents on quantitative accuracy of PET in combined whole-body PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lois, Cristina [University of Santiago de Compostela, Department of Particle Physics, Santiago de Compostela (Spain); Health Research Institute of Santiago de Compostela (IDIS), Santiago de Compostela (Spain); Imaging Science Institute, Tuebingen (Germany); Bezrukov, Ilja [Eberhard Karls University, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens Foundation, Department of Preclinical Imaging and Radiopharmacy, Tuebingen (Germany); Max Plank Institute for Intelligent Systems, Department of Empirical Inference, Tuebingen (Germany); Schmidt, Holger [Eberhard Karls University, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens Foundation, Department of Preclinical Imaging and Radiopharmacy, Tuebingen (Germany); Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Schwenzer, Nina; Werner, Matthias K. [Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Kupferschlaeger, Juergen [Eberhard Karls University, Nuclear Medicine, Department of Radiology, Tuebingen (Germany); Beyer, Thomas [Imaging Science Institute, Tuebingen (Germany); cmi-experts GmbH, Zuerich (Switzerland)

    2012-11-15

    Clinical PET/MR acquisition protocols entail the use of MR contrast agents (MRCA) that could potentially affect PET quantification following MR-based attenuation correction (AC). We assessed the effect of oral and intravenous (IV) MRCA on PET quantification in PET/MR imaging. We employed two MRCA: Lumirem {sup registered} (oral) and Gadovist {sup registered} (IV). First, we determined their reference PET attenuation values using a PET transmission scan (ECAT-EXACT HR+, Siemens) and a CT scan (PET/CT Biograph 16 HI-REZ, Siemens). Second, we evaluated the attenuation of PET signals in the presence of MRCA. Phantoms were filled with clinically relevant concentrations of MRCA in a background of water and {sup 18}F-fluoride, and imaged using a PET/CT scanner (Biograph 16 HI-REZ, Siemens) and a PET/MR scanner (Biograph mMR, Siemens). Third, we investigated the effect of clinically relevant volumes of MRCA on MR-based AC using human pilot data: a patient study employing Gadovist {sup registered} (IV) and a volunteer study employing two different oral MRCA (Lumirem {sup registered} and pineapple juice). MR-based attenuation maps were calculated following Dixon-based fat-water segmentation and an external atlas-based and pattern recognition (AT and PR) algorithm. IV and oral MRCA in clinically relevant concentrations were found to have PET attenuation values similar to those of water. The phantom experiments showed that under clinical conditions IV and oral MRCA did not yield additional attenuation of PET emission signals. Patient scans showed that PET attenuation maps are not biased after the administration of IV MRCA but may be biased, however, after ingestion of iron oxide-based oral MRCA when segmentation-based AC algorithms are used. Alternative AC algorithms, such as AT and PR, or alternative oral contrast agents, such as pineapple juice, can yield unbiased attenuation maps. In clinical PET/MR scenarios MRCA are not expected to lead to markedly increased attenuation

  9. Investigation of the mechanical performance of Siemens linacs components during arc

    DEFF Research Database (Denmark)

    Rowshanfarzad, Pejman; Häring, Peter; Lynggaard Riis, Hans

    2015-01-01

    to linac rotation were separately investigated by acquisition of 37 EPID images of a simple phantom with five ball bearings at various gantry angles. A fast and robust software package was developed for automated analysis of image data. Three Siemens linacs were investigated. RESULTS: The average EPID sag...... for effective investigation of the behavior of Siemens linac components with gantry rotation. Such a comprehensive study has been performed for the first time on Siemens machines....

  10. Dedicated accelerator and microprobe line

    International Nuclear Information System (INIS)

    Malmqvist, K.G.; Hylten, G.; Hult, M.; Haakansson, K.; Knox, J.M.; Larsson, N.P.O.; Nilsson, C.; Pallon, J.; Schofield, R.; Swietlicki, E.; Tapper, U.A.S.; Yang Changyi

    1993-01-01

    The development of a dedicated facility for nuclear microprobe analysis and the experiences from using it are discussed. The general properties of the present Lund nuclear microprobe will be described and the advantages of using a dedicated accelerator discussed. (orig.)

  11. Christ siemens touraine syndrome: A rare case report

    Directory of Open Access Journals (Sweden)

    N Retnakumari

    2016-01-01

    Full Text Available Christ-Siemens-Touraine (CST is a rare hereditary disorder of X-linked recessive trait, characterized by abnormal development of two or more structures or tissues of ectodermal origin. The common clinical findings include hypodontia, hypohydrosis, hypotrichosis, and onychodysplasia. Although hypodontia is common, anodontia is a rare feature. Most of the patients are suffering from social rejection and consequent psychological trauma because of the facial dysmorphism and absence of multiple teeth. Oral rehabilitation is of prime importance for such patients. This article presents a case in a 5½-year-old boy presenting with altered manifestations affecting almost all the ectodermal structures like skin, hair, nails, teeth, sebaceous glands, sweat glands, salivary glands, mammary glands, and tear glands. He also had complete anodontia and dry mouth. A multidisciplinary treatment was given to the patient with the collaboration of various health professionals. The child gained confidence and was relieved from the psychological impact following the prosthetic rehabilitation.

  12. Siemens Nuclear Power Corporation experience with BWR and PWR fuels

    International Nuclear Information System (INIS)

    Reparaz, A.; Smith, M.H.; Stephens, L.G.

    1992-01-01

    The large data base of fuel performance parameters available to Siemens Nuclear Power Corporation (SNP), and the excellent track record of innovation and fuel reliability accumulated over the last twenty-three years, allows SNP to have a clear insight on the characteristics of future developments in the area of fuel design. Following is a description of some of SNP's recent design innovations to prevent failures and to extend burnup capabilities. A goal paramount to the design and manufacture of BWR and PWR fuel is that of zero defects from any case during its operation in the reactor. Progress has already been made in achieving this goal. This paper summarized the cumulative failure rate of SNP fuel rod through January 1992

  13. Siemens' innovative role in mining technology

    Energy Technology Data Exchange (ETDEWEB)

    1990-07-01

    The growth of the mining industry in South Africa has played a decisive role in the industrial development of the country. As mining activities expanded, the need for energy production increased and as of late mining is becoming more mechanised and the need for more energy as well as automation is growing. The origins of Siemens operations in South Africa date back to the humble beginnings of the mining era, when the company provided the first generator and floodlights to illuminate the famous 'Big Hole' of the diamond mine at Kimberley as well as hydro-electric plants in 1895 on the Crocodile River and Blyde River respectively to supply the newly established mines in the Lydenburg district with electric power. 7 figs.

  14. Christ Siemens Touraine syndrome: A rare case report.

    Science.gov (United States)

    Retnakumari, N; Varghese, Manuja; Kannan, V P

    2016-01-01

    Christ-Siemens-Touraine (CST) is a rare hereditary disorder of X-linked recessive trait, characterized by abnormal development of two or more structures or tissues of ectodermal origin. The common clinical findings include hypodontia, hypohydrosis, hypotrichosis, and onychodysplasia. Although hypodontia is common, anodontia is a rare feature. Most of the patients are suffering from social rejection and consequent psychological trauma because of the facial dysmorphism and absence of multiple teeth. Oral rehabilitation is of prime importance for such patients. This article presents a case in a 5½-year-old boy presenting with altered manifestations affecting almost all the ectodermal structures like skin, hair, nails, teeth, sebaceous glands, sweat glands, salivary glands, mammary glands, and tear glands. He also had complete anodontia and dry mouth. A multidisciplinary treatment was given to the patient with the collaboration of various health professionals. The child gained confidence and was relieved from the psychological impact following the prosthetic rehabilitation.

  15. Analysis of the initial experience with first PET scanner and in Chile

    International Nuclear Information System (INIS)

    Massardo, Teresa; Jofre, Maria Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Valdebenito, Robert; Galaz, Rodrigo

    2005-01-01

    The main application of positron emission tomography (PET) with Fluorine 18- deoxyglucose (FDG) is in the management of cancer patients due to the high correlation between cellular glucidic activity and malignancy. Objective: To analyze the initial group of cases performed with the first dedicated PET scanner in Chile. Method: We present the first 500 patients studied with a Siemens HR+ system using FDG produced at the Chilean Atomic Energy Commission facilities. Results: Most of the referrals were from oncology (96%). Four percent were studied due to neurological or psychiatric disorders and only 1% for myocardial viability. Lung lesions, gastrointestinal and breast carcinomas, melanoma and lymphoma corresponded to the most frequent diagnosis. Lung and lymphoma patients had clinical follow-up. There was good concordance with anatomical images and histology in those cases with available data. Fusion of FDG images with computed tomography or magnetic resonance was helpful. In a significant number of patients new tumoral sites were detected Conclusion: We confirm that in clinical practice, metabolic imaging with F18-FDG is helpful for cancer evaluation and management (au)

  16. Analysis of the initial experience with first PET scanner and in Chile

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa; Jofre, Maria Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Valdebenito, Robert; Galaz, Rodrigo [Centro PET de Imagenes Moleculares, Hospital Militar da Santiago, Santiago (Chile)

    2005-07-01

    The main application of positron emission tomography (PET) with Fluorine 18- deoxyglucose (FDG) is in the management of cancer patients due to the high correlation between cellular glucidic activity and malignancy. Objective: To analyze the initial group of cases performed with the first dedicated PET scanner in Chile. Method: We present the first 500 patients studied with a Siemens HR+ system using FDG produced at the Chilean Atomic Energy Commission facilities. Results: Most of the referrals were from oncology (96%). Four percent were studied due to neurological or psychiatric disorders and only 1% for myocardial viability. Lung lesions, gastrointestinal and breast carcinomas, melanoma and lymphoma corresponded to the most frequent diagnosis. Lung and lymphoma patients had clinical follow-up. There was good concordance with anatomical images and histology in those cases with available data. Fusion of FDG images with computed tomography or magnetic resonance was helpful. In a significant number of patients new tumoral sites were detected Conclusion: We confirm that in clinical practice, metabolic imaging with F18-FDG is helpful for cancer evaluation and management (au)

  17. Validation of a simultaneous PET/MR system model for PET simulation using GATE

    International Nuclear Information System (INIS)

    Monnier, Florian; Fayad, Hadi; Bert, Julien; Schmidt, Holger; Visvikis, Dimitris

    2015-01-01

    Simultaneous PET/MR acquisition shows promise in a range of applications. Simulation using GATE is an essential tool that allows obtaining the ground truth for such acquisitions and therefore helping in the development and the validation of innovative processing methods such as PET image reconstruction, attenuation correction and motion correction. The purpose of this work is to validate the GATE simulation of the Siemens Biograph mMR PET/MR system. A model of the Siemens Biograph mMR was developed. This model includes the geometry and spatial positioning of the crystals inside the scanner and the characteristics of the detection process. The accuracy of the model was tested by comparing, on a real physical phantom study, GATE simulated results to reconstructed PET images using measured results obtained from a Siemens Biograph mMR system. The same parameters such as the acquisition time and phantom position inside the scanner were fixed for our simulations. List-mode outputs were recovered in both cases and reconstructed using the OPL-EM algorithm. Several parameters were used to compare the two reconstructed images such as profile comparison, signal-to-noise ratio and activity contrast analysis. Finally patient acquired MR images were segmented and used for the simulation of corresponding PET images. The simulated and acquired sets of reconstructed phantom images showed close emission values in regions of interest with relative differences lower than 5%. The scatter fraction was within a <3% agreement. Close matching of profiles and contrast indices were obtained between simulated and corresponding acquired PET images. Our results indicate that the GATE developed Biograph mMR model is accurate in comparison to the real scanner performance and can be used for evaluating innovative processing methods for applications in clinical PET/MR protocols.

  18. Performance evaluation of siemens CTI ECAT EXACT 47 scanner using NEMA NU2-2001

    International Nuclear Information System (INIS)

    Kim, Jin Su; Lee, Jae Sung; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul

    2004-01-01

    NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. In this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: 250 ∼ 650 keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post-processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by 1∼5 aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity were estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates were measured for 7 half-lives to obtain noise equivalent count rate (NECR) and scatter fraction. We confirmed that dead time loss of the last frame were below 1%. Scatter fraction was estimated by averaging the true to background (scatter + random) ratios of last 3 frames in which the fractions of random rate are negligibly small. Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D

  19. Christ Siemens Touraine syndrome: Two case reports and felicitous approaches to prosthetic management

    Directory of Open Access Journals (Sweden)

    Navanith Renahan

    2015-01-01

    Full Text Available Ectodermal dysplasia is a heterogeneous group of inherited disorders, which exhibit a classic triad of hypohydrosis, hypotrichosis, and hypodontia. Hypohidrotic or anhidrotic ectodermal dysplasia or Christ Siemens Touraine syndrome is the most common condition among ectodermal dysplasia patients. This is a case report on two Christ Siemens Touraine syndrome cases and two different approaches to prosthetic management.

  20. Siemens meelitab Eestisse 150 töökohta / Raigo Neudorf

    Index Scriptorium Estoniae

    Neudorf, Raigo

    2002-01-01

    Saksamaa elektroonikafirma Siemens tütarfirma Eestis võistleb selle eest, et tuua Eestisse emafirma 150 pakutavat töökohta majandustarkvara koostavatele spetsialistidele. Tabelid: Siemens Grupp Eesti tähtsamad majandusnäitajad. Siemensi kontsern

  1. Usefulness of FDG-PET in the evaluation of patients with colon and rectal cancer in a PET center in Chile

    Energy Technology Data Exchange (ETDEWEB)

    Jofre, M J; Massardo, L T; Canessa, J; Sierralta, P; Gonzalez, P [Molecular Imaging PET Center, Nuclear Medicine Department, Military Hospital, Santiago (Chile)

    2007-11-15

    Introduction: FDG, PET is a useful imaging technique in the management of patients with gastrointestinal tumours, mainly in oesophageal and colorectal cancer. In Chile, colorectal cancer is a prevalent disease, representing the 7th cause of death in men and 6th in women. The aim of the study was to assess FDG-PET value in the management of colorectal cancer in the first PET center in Chile. Material and Methods: Population: In a retrospective analysis, we studied 130 patients with 159 PET scans, 56% corresponded to women. Group A rectal cancer: 42 patients (55 studies), mean age 61 {+-} 11 y.o. (range 39-80) Group B colon cancer: 88 patients (104 studies), mean age 61 {+-} 11 y.o. (range 39-80). Referral: In the whole population, 53% were studied by recurrence suspicion (31% with increased CEA levels with negative anatomical imaging), 33% for re-staging, 8% for therapy control and 6% for staging. Eighty-five % was submitted to surgery (range: lm -7y) and 42% presented local or distance dissemination; 70% have received chemotherapy and 23% associated radiotherapy. Technique: Whole-body images were acquired with a dedicated high resolution PET Siemens Ecat Exact HR+ camera 60 minutes after injection of intravenous F18-FDG, produced at the Chilean Nuclear Energy Commission (mean dose: 12 mCi). Visual analysis and semi-quantitative standardized uptake value (SUV) were performed by a consensus of 5 nuclear medicine physicians. Results: 65% of the PET studies were positive, showing hypermetabolic tumoral uptake (63% studies in colon cancer and 69% in rectal cancer). In 30% from the positive cases liver lesions were found, 52% of them without other lesions. In 75% from positive studies there was extrahepatic involvement. In the group B, local recurrence was found in 37%. In 48% cases there was good correlation between anatomical images available and FDG and in 42% new unknown lesions were found with PET. CEA levels: they were available in 62% of the cases (71% of them

  2. Siemens IT solutions for power sector. PROFIT solutions

    International Nuclear Information System (INIS)

    Lunter, P.

    2004-01-01

    The cost reduction, flexibility and revenue increase, potential exploitation, productivity increase, and business opportunities exploitation - that is all what can be required in the races for the promonent positioning on the electricity power market. These requirements can be realized by the sophisticated IT solutions hand-tailored to the special requirements of the electric power producers and tradesmen. This approach makes it possible to achieve greater profit. Our solutions 'PROFIT Solutions', that are symbiosis of the most progressive information technologies and the power plant techniques of the company Siemens, satisfy submitted specifications in substantial measure. The system solutions 'PROFIT Solutions' comprise three solution groups: process, operation a business. The solutions of the group 'IT Process Solutions' increase flexibility and manoeuvrability of equipment, improve the efficiency and contribute to more economical operation of the power generation. Solutions 'IT Process Solutions' simplify and shorten the period of power cycles and conduce to higher labour productivity. Solutions group 'IT Process Solutions' approaches equipment to the market - supports the profit strategies, helps quickly and expertly to determine and predict hazards. The extension PROFIT Cockpit means the nuance to the solutions world 'PROFIT Solutions'. The survey about the whole installation is within reach at the simple touch of a button. It is possible to compile the total system part by part from single solutions 'PROFIT Solutions'. As a matter of fact all single parts can be interconnected with already existing solutions. Routines 'PROFIT Solutions' cooperate with all modern control systems. (author)

  3. Type testing of the Siemens Plessey electronic personal dosemeter.

    Science.gov (United States)

    Hirning, C R; Yuen, P S

    1995-07-01

    This paper presents the results of a laboratory assessment of the performance of a new type of personal dosimeter, the Electronic Personal Dosemeter made by Siemens Plessey Controls Limited. Twenty pre-production dosimeters and a reader were purchased by Ontario Hydro for the assessment. Tests were performed on radiological performance, including reproducibility, accuracy, linearity, detection threshold, energy response, angular response, neutron response, and response time. There were also tests on the effects of a variety of environmental factors, such as temperature, humidity, pulsed magnetic and electric fields, low- and high-frequency electromagnetic fields, light exposure, drop impact, vibration, and splashing. Other characteristics that were tested were alarm volume, clip force, and battery life. The test results were compared with the relevant requirements of three standards: an Ontario Hydro standard for personal alarming dosimeters, an International Electrotechnical Commission draft standard for direct reading personal dose monitors, and an International Electrotechnical Commission standard for thermoluminescence dosimetry systems for personal monitoring. In general, the performance of the Electronic Personal Dosemeter was found to be quite acceptable: it met most of the relevant requirements of the three standards. However, the following deficiencies were found: slow response time; sensitivity to high-frequency electromagnetic fields; poor resistance to dropping; and an alarm that was not loud enough. In addition, the response of the electronic personal dosimeter to low-energy beta rays may be too low for some applications. Problems were experienced with the reliability of operation of the pre-production dosimeters used in these tests.

  4. Implementing Open Innovation: The Case of Natura, IBM and Siemens

    Directory of Open Access Journals (Sweden)

    Cely Ades

    2013-05-01

    Full Text Available This paper analyses three case firms whose innovation management processes have been consolidated. The companies Natura, IBM (Brazilian Subsidiary and Siemens (ChemTech/Brazil were studied with the purpose of analysing the implementation of OI, particularly in terms of: (a its alignment with existing corporate strategy; (b its requirements such as culture, skill and motivation; (c the strategy and the implementation process; (d the results achieved (e the present barriers and enablers. The research is qualitative in nature and employs a descriptive approach. The main results of this study, obtained using a method called ‘Collective Subject Speech’ , show that the implementation of OI, both structured and non-structured, is mainly challenged by cultural issues. It has been observed that the implementation of OI process is at its embryonic stage in all case firms and that this occurs along with investments in closed innovation, meaning that OI results cannot be explored at this stage of the implementation, as there is a long way to consolidate these practices in the case firms studied.

  5. PET/MR Imaging in Gynecologic Oncology.

    Science.gov (United States)

    Ohliger, Michael A; Hope, Thomas A; Chapman, Jocelyn S; Chen, Lee-May; Behr, Spencer C; Poder, Liina

    2017-08-01

    MR imaging and PET using 2-Deoxy-2-[ 18 F]fluoroglucose (FDG) are both useful in the evaluation of gynecologic malignancies. MR imaging is superior for local staging of disease whereas fludeoxyglucose FDG PET is superior for detecting distant metastases. Integrated PET/MR imaging scanners have great promise for gynecologic malignancies by combining the advantages of each modality into a single scan. This article reviews the technology behind PET/MR imaging acquisitions and technical challenges relevant to imaging the pelvis. A dedicated PET/MR imaging protocol; the roles of PET and MR imaging in cervical, endometrial, and ovarian cancers; and future directions for PET/MR imaging are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Gas Nozzle Effect on the Deposition of Polysilicon by Monosilane Siemens Reactor

    Directory of Open Access Journals (Sweden)

    Seung Oh Kang

    2012-01-01

    Full Text Available Deposition of polysilicon (poly-Si was tried to increase productivity of poly-Si by using two different types of gas nozzle in a monosilane Bell-jar Siemens (MS-Siemens reactor. In a mass production of poly-Si, deposition rate and energy consumption are very important factors because they are main performance indicators of Siemens reactor and they are directly related with the production cost of poly-Si. Type A and B nozzles were used for investigating gas nozzle effect on the deposition of poly-Si in a MS-Siemens reactor. Nozzle design was analyzed by computation cluid dynamics (CFD. Deposition rate and energy consumption of poly-Si were increased when the type B nozzle was used. The highest deposition rate was 1 mm/h, and the lowest energy consumption was 72 kWh⋅kg-1 in this study.

  7. Analysing the Outbound logistics process enhancements in Nokia-Siemens Networks Global Distribution Center

    OpenAIRE

    Marjeta, Katri

    2011-01-01

    Marjeta, Katri. 2011. Analysing the outbound logistics process enhancements in Nokia-Siemens Networks Global Distribution Center. Master´s thesis. Kemi-Tornio University of Applied Sciences. Business and Culture. Pages 57. Due to confidentiality issues, this work has been modified from its original form. The aim of this Master Thesis work is to describe and analyze the outbound logistics process enhancement projects executed in Nokia-Siemens Networks Global Distribution Center after the N...

  8. Lung PET scan

    Science.gov (United States)

    ... Chest PET scan; Lung positron emission tomography; PET - chest; PET - lung; PET - tumor imaging; ... Grainger & Allison's Diagnostic Radiology: A Textbook of Medical Imaging . 6th ed. Philadelphia, ...

  9. Dedication

    NARCIS (Netherlands)

    Hoek, van den C.

    1967-01-01

    Joséphine Th. Koster entered her service at the Rijksherbarium as an assistant, April 1930, in the midst of the economic crisis. She was engaged as an, unsalaried collaborator, the then current type of position the Netherlands’ State could offer its scientific offspring. When Prof. Dr. H. J. Lam,

  10. Dedication

    NARCIS (Netherlands)

    NN,

    1948-01-01

    It is not without some pride and much satisfaction that the present volume, fourth planned in the series, second in sequence of publication, is brought to a successful end. Satisfaction I feel through the fact that the scheme and aim of this work is not only understood by the scientific-botanical

  11. Dedication

    NARCIS (Netherlands)

    Holttum, R.E.

    1959-01-01

    CARL FREDRICK ALBERT CHRISTENSEN (1872-1942) was the founder of modern fern taxonomy. To appreciate the scope of his work, it is necessary to understand the confusions of thought on the subject which persisted through the 19th century and were still evident in the summary prepared (by DIELS) for

  12. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  13. Automatic extraction of forward stroke volume using dynamic PET/CT

    DEFF Research Database (Denmark)

    Harms, Hans; Tolbod, Lars Poulsen; Hansson, Nils Henrik Stubkjær

    2015-01-01

    Background The aim of this study was to develop and validate an automated method for extracting forward stroke volume (FSV) using indicator dilution theory directly from dynamic positron emission tomography (PET) studies for two different tracers and scanners. Methods 35 subjects underwent...... a dynamic 11 C-acetate PET scan on a Siemens Biograph TruePoint-64 PET/CT (scanner I). In addition, 10 subjects underwent both dynamic 15 O-water PET and 11 C-acetate PET scans on a GE Discovery-ST PET/CT (scanner II). The left ventricular (LV)-aortic time-activity curve (TAC) was extracted automatically...... from PET data using cluster analysis. The first-pass peak was isolated by automatic extrapolation of the downslope of the TAC. FSV was calculated as the injected dose divided by the product of heart rate and the area under the curve of the first-pass peak. Gold standard FSV was measured using phase...

  14. Scalable cloud without dedicated storage

    Science.gov (United States)

    Batkovich, D. V.; Kompaniets, M. V.; Zarochentsev, A. K.

    2015-05-01

    We present a prototype of a scalable computing cloud. It is intended to be deployed on the basis of a cluster without the separate dedicated storage. The dedicated storage is replaced by the distributed software storage. In addition, all cluster nodes are used both as computing nodes and as storage nodes. This solution increases utilization of the cluster resources as well as improves fault tolerance and performance of the distributed storage. Another advantage of this solution is high scalability with a relatively low initial and maintenance cost. The solution is built on the basis of the open source components like OpenStack, CEPH, etc.

  15. The role of nuclear power in external and internal communications at Siemens

    International Nuclear Information System (INIS)

    Breyer, Wolfgang

    1999-01-01

    'Der Spiegel', quotes Siemens CEO as saying that the nuclear business accounts for 2 percent of the business but for 95 percent of his troubles. The communications organization at Siemens is rather complex. As a consequence of the political relevance of energy technology, KWU has a public relations department addressing a broad spectrum of stake holders, runs a quarterly magazine on energy and environmental policy called Standpunkt, (Viewpoint) and has, the largest press office of all Siemens Groups. These entities also contribute to the corporate media for internal and external communications. When the nuclear controversy in Germany reached its first culmination in the mid-1970s, Kraftwerk Union, the forerunner of what is now the Siemens Power Generation Group (KWU), automatically became a leading voice on the pro-nuclear side because, as turnkey contractor for most of Germany's NPPs, it had the deepest knowledge of the technology whereas the owner/operator side was and is organized in several utilities. From the German experience with anti-nuke campaign one could draw the following conclusions: (1) A political,, technology like nuclear necessarily leads to a high profile in the public. As the No. nuclear supplier in Germany Siemens doesn't have the option of a low profile; (2) As a consequence, the nuclear business gets unproportional attention in the public. Siemens has to take this into account in order to assure its other business areas enough visibility; (3) For public relations on nuclear power, the internal audience is as important as the external one. Because of the large work-force of Siemens, internal communications have a significant multiplication effect for the external audience; (4) A broad spectrum of non-nuclear activities doesn't make a company like Siemens more vulnerable to public pressure than a mono-structured company. On the contrary: The high prestige gained in its other business fields makes it easier to defend the nuclear business as

  16. The PHWR of Siemens as appropriate type of the SMPR-class

    International Nuclear Information System (INIS)

    Herzog, G.; Doerfler, U.; Loos, F.

    1988-01-01

    Siemens started its NPP-activities with the development and construction of a number of small and medium size power reactor (SMPR) plants, using different reactor types (PHWRs, PWRs and BWRs). Siemens applied its proven technological modules successfully to all types of nuclear power plants as it is demonstrated by the high availability figures published every year. Based on the experience gained from Atucha I and II, the Argentinian engineering company ENACE (of which KWU holds 25% of the shares) has developed the ARGOS 380, a NPP in the SMPR-class, as an advanced continuation of the KWU PHWR series. The technology transfer provided by Siemens in the course of NPP construction includes all activities in the engineering, construction, manufacturing and erection/commissioning field. Additionally Siemens is prepared to assist in the transfer of manufacturing know-how. On the basis of its successful activities in this field for years, Siemens disposes of all instruments for an efficient know-how transfer. (orig.)

  17. Evaluation of pulmonary nodules and lung cancer with one-inch crystal gamma coincidence positron emission tomography/CT versus dedicated positron emission tomography/CT

    International Nuclear Information System (INIS)

    Moodie, K.; Lau, E.; Hicks, R. J.; Cherk, M. H.; Turlakow, A.; Skinner, S.; Kelly, M. J.; Kalff, V.

    2009-01-01

    Full text: Dedicated positron emission tomography (PET)/CT scanners using BGO and related detectors (d-PET) have become standard imaging instruments in many malignancies. Hybrid gamma camera systems using Nal detectors in coincidence mode (g-PET) have been compared to d-PET but reported usefulness has been variable when gamma cameras with half-inch to three-fourth-inch thick crystals have been used without CT. Our aim was to compare g-PET with a 1-in.-thick crystal and inbuilt CT for lesion localization and attenuation correction (g-PET/CT) and d-PET/CT in patients presenting with potential and confirmed lung malignancies. One hour after 18F-fluorodeoxyglucose (FDG), patients underwent BGO d-PET/CT from jaw to proximal thigh. This was followed by one to two bed position g-PET/CT 194 + 27 min after FDG. Each study pair was independently analysed with concurrent CT. d-PET/CT was interpreted by a radiologist experienced in both PET and CT, and g-PET/CT by consensus reading of an experienced PET physician and an experienced CT radiologist, A TNM score was assigned and studies were then unblinded and compared. Fifty-seven patients underwent 58 scan pairs over 2 years. Eighty-nine percent concordance was shown between g-PET/CT and d-PET/CT for the assessment of I intrapulmonary lesions, with 100% concordance for intrapulmonary lesions I >10 mm (36 of 36). Eighty-eight per cent (51 of 58) concordance was shown between g-PET/CTand d-PET/CTforTNM staging. Coincidence imaging usingan optimized dual-head 1-in.-thick crystal gamma camera with inbuilt CT compares reasonably well with dedicated PET/CT for evaluation of indeterminate pulmonary lesions and staging of pulmonary malignancies and may be of some] value when d-PET/CT is not readily available.

  18. CyberPET: a PET service distributed over a wide area

    International Nuclear Information System (INIS)

    Pilloy, W.J.; Hellwig, D.; Schaeffer, A.; Hoffmann, P.; Lens, V.

    2002-01-01

    Aim: Demonstration of bi-directional PET data transmission, interactive display and co-registration, for the purpose of correlative imaging, treatment planning and teaching. Material and Method: In the year 2000, the initial problem to attend was to provide an effective PET service to a hospital (in Luxemburg) which lies 150 km away from a PET center (in another country). Once this solved, the procedure was expanded (in 2001) to co-registration with CT/MRI scans performed locally, and with radiotherapy simulation CT performed in another center 25 km away (in 2002). Equipment from various vendors was used (Siemens, Adac, GE, Hermes). With preliminary agreement of the national medical aid, patients are sent from the Nuclear Medicine Dept of the Centre Hospitalier in Luxemburg (CHL) to the Dept NM of the Saarland University Medical Center for PET examination. The digital data are then sent from the Siemens PET camera to a PC connected to the LAN, and then to a FTP server (Healthnet). The data are similarly collected by a PC of the hospital network in Luxemburg, and transferred to a Hermes NM station. The Dicom PET data are converted on the fly to Interfile, displayed interactively as any other tomographic data, printed and available on the NM image server. Since 2001, the PET data are co-registered with whole-body CT data recorded at CHL according to a specific protocol (see other paper of this group). Now in 2002, we are busy implementing the co-registration of PET data and simulation CT data obtained from the Centre Baclesse (CFB, 25 km from CHL) for the treatment planning of brain tumours (input into an ADAC system). Furthermore, we plan to send the data (after deletion of their digital ID) to a (South African) university which does not yet dispose of a PET camera, to allow the training of their registrars. Results: For the end-user clinician at CHL and CFB , the PET data have the quality of 'live data', which can be examined interactively, along with other imaging

  19. Results from Operational Testing of the Siemens Smart Grid-Capable Electric Vehicle Supply Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, Brion [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-05-01

    The Idaho National Laboratory conducted testing and analysis of the Siemens smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from Siemens for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the Siemens smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormal conditions testing, and charging of a plug-in vehicle.

  20. Introducing life cycle thinking in product development – A case from Siemens Wind Power

    DEFF Research Database (Denmark)

    Bonou, Alexandra; Olsen, Stig Irving; Hauschild, Michael Zwicky

    2015-01-01

    How can use of LCA improve the environmental sustainability of wind industry products? An analysis of a case study from Siemens Wind Power identifies the knowledge offered by LCA that is relevant to each step of the product development process (PDP). The study illustrates the difference that this......How can use of LCA improve the environmental sustainability of wind industry products? An analysis of a case study from Siemens Wind Power identifies the knowledge offered by LCA that is relevant to each step of the product development process (PDP). The study illustrates the difference...

  1. GOING GLOBAL — ACTING LOCAL: SIEMENS IN THE CHINESE ELECTRICAL MARKET, 1904-1937

    Directory of Open Access Journals (Sweden)

    Mathias Mutz

    2011-01-01

    Full Text Available The German electrical manufacturer Siemens has been active in the Chinese market since the 1870s and established its first office in Shanghai in 1904. Focusing on marketing, the paper analyzes Siemens' business activities in China in the period from 1904 to 1937, and argues that the company exemplified a strategy of "glocalization," i.e. combining global business objectives and local adjustments. At the same time, the growing importance of international markets affected the development of the company as a whole. Referring to the contributions of "product," "price, "place" and "promotion" to the enterprise's development, this paper emphasizes the close connection between marketing and internationalization.

  2. The role of passive and inherent safety properties in Siemens/KWU nuclear power plants

    International Nuclear Information System (INIS)

    Gremm, O.

    1990-01-01

    In Siemens/KWU Nuclear Power Plants the applied safety concept consist of a well balanced combination of active, passive use well is inherent safety measures. In principle it is not possible to realise a safety concept exclusively with inherent and/or passive safety properties. The respective measures and arguments will be explained in detail in the presentation. In addition the Siemens/KWU safety concept with examples of the role of inherent and passive safety measures will be illustrated. (author). 9 refs, 9 figs

  3. Current status and future perspective of PET

    International Nuclear Information System (INIS)

    Lee, Myung Chul

    2002-01-01

    Positron Emission Tomography (PET) is a nuclear medicine imaging modality that consists of systemic administration to a subject of a radiopharmaceutical labeled with a positron-emitting radionuclide. Following administration, its distribution in the organ or structure under study can be assessed as a function of time and space by (1) detecting the annihilation radiation resulting from the interaction of the positrons with matter, and (2) reconstructing the distribution of the radioactivity from a series of that used in computed tomography (CT). The nuclides most generally exhibit chemical properties that render them particularly desirable in physiological studies. The radionuclides most widely used in PET are F-18, C-11, O-15 and N-13. Regarding to the number of the current PET Centers worldwide (based on ICP data), more than 300 PET Centers were in operation in 2000. The use of PET technology grew rapidly compared to that in 1992 and 1996, particularly in the USA, which demonstrates a three-fold rise in PET installations. In 2001, 194 PET Centers were operating in the USA. In 1994, two clinical and research-oriented PET Centers at Seoul National University Hospital and Samsung Medical Center, was established as the first dedicated PET and Cyclotron machines in Korea, followed by two more PET facilities at the Korea Cancer Center Hospital, Ajou Medical Center, Yonsei University Medical Center, National Cancer Center and established their PET Center. Catholic Medical School and Pusan National University Hospital have finalized a plan to install PET machine in 2002, which results in total of nine PET Centers in Korea. Considering annual trends of PET application in four major PET centers in Korea in Asan Medical Center recent six years (from 1995 to 2000), a total of 11,564 patients have been studied every year and the number of PET studies has shown steep growth year upon year. We had, 1,020 PET patients in 1995. This number increased to 1,196, 1,756, 2,379, 3

  4. PET and SPECT in neurology

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium). Dept. of Radiology and Nuclear Medicine; Vries, Erik F.J. de; Waarde, Aren van [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Otte, Andreas (ed.) [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology

    2014-07-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  5. PET and SPECT in neurology

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Ghent Univ.; Vries, Erik F.J. de; Waarde, Aren van; Otte, Andreas

    2014-01-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  6. Extraction of left ventricular myocardial mass from dynamic 11C-acetate PET

    DEFF Research Database (Denmark)

    Harms, Hans; Tolbod, Lars Poulsen; Hansson, Nils Henrik

    Background: Dynamic 11C-acetate PET is used to quantify oxygen metabolism, which is used to calculate left ventricular (LV) myocardial efficiency, an early marker of heart failure. This requires estimation of LV myocardial mass and is typically derived from a separate cardiovascular magnetic...... resonance (CMR) scan. The aim of this study was to explore the feasibility of estimating myocardial mass directly from a dynamic 11C-acetate PET scan. Methods: 21 subjects underwent a 27-min 11C-acetate PET scan on a Siemens Biograph TruePoint 64 PET/CT scanner. In addition, 10 subjects underwent a dynamic...... 11C-acetate 27-min PET scan on a GE Discovery ST PET/CT scanner. Parametric images of uptake rate K1 and both arterial (VA) and venous (VV) spillover fractions were generated using a basis function implementation of the standard single tissue compartment model using non-gated dynamic data. The LV...

  7. Performance evaluation of Siemens E.Cam® Spect System at Korle ...

    African Journals Online (AJOL)

    Performance evaluation of Siemens E.Cam® Spect System at Korle-Bu Teaching Hospital (Ghana. ... The tests were performed according to National Electrical Manufac-turers Association protocols, and different measuring instruments and phantoms containing 99m-Tc were used. Extrinsic uniformity, System energy ...

  8. Kinetic data bank for Ramona of the Siemens 9x9-IX

    International Nuclear Information System (INIS)

    Alonso V, G.

    1993-12-01

    With the purpose of making the transitory analyses of the Laguna Verde Nuclear Power station when Siemens fuel of the type 9x9-IX is used, proposed for the cycle 2 of the Unit 2, the kinetic data bank in hot condition for the Ramona code has been generated. (Author)

  9. Siemens Wind Power 3.6 MW wind turbines for large offshore wind farms

    Energy Technology Data Exchange (ETDEWEB)

    Akhmatov, Vladislav; Nygaard Nielsen, Joergen; Thisted, Jan; Groendahl, Erik; Egedal, Per; Noertoft Frydensbjerg, Michael; Jensen, Kim Hoej [Siemens Wind Power A/S, Brande (Denmark)

    2008-07-01

    Siemens Wind power A/S is the key player on the offshore wind power market. The Siemens Wind Power 3.6 MW variable-speed wind turbine is among the word's largest, most advanced and competitive wind turbines with a solid portfolio of large offshore wind farms. Transmission system operators and developers require dynamic wind turbine models for evaluation of fault-ride-through capability and investigations of power system stability. The even larger size of the on- and offshore wind farms has entailed that the grid impact of the voltage and frequency control capability of the wind farm can be appropriated modelled and evaluated. Siemens Wind Power has developed a dynamic model of the 3.6 MW variable-speed wind turbine with the fault-ride-through sequences and models of the voltage and frequency controllers to be applied for large offshore wind farms. The dynamic models have been implemented in the commercially available simulation tools such as DIgSILENT PowerFactory and Siemens PTI PSS/E and successfully validated from measurements. (orig.)

  10. 78 FR 25304 - Siemens Medical Solutions, USA, Inc., Oncology Care Systems (Radiation Oncology), Including On...

    Science.gov (United States)

    2013-04-30

    ..., USA, Inc., Oncology Care Systems (Radiation Oncology), Including On-Site Leased Workers From Source... Medical Solutions, USA, Inc., Oncology Care Systems (Radiation Oncology), including on- site leased... of February 2013, Siemens Medical Solutions, USA, Inc., Oncology Care Systems (Radiation Oncology...

  11. Image reconstruction of mMR PET data using the open source software STIR

    Energy Technology Data Exchange (ETDEWEB)

    Markiewicz, Pawel [Centre for Medical Image Computing, University College London, London (United Kingdom); Thielemans, Kris [Institute of Nuclear Medicine, University College London, London (United Kingdom); Burgos, Ninon [Centre for Medical Image Computing, University College London, London (United Kingdom); Manber, Richard [Institute of Nuclear Medicine, University College London, London (United Kingdom); Jiao, Jieqing [Centre for Medical Image Computing, University College London, London (United Kingdom); Barnes, Anna [Institute of Nuclear Medicine, University College London, London (United Kingdom); Atkinson, David [Centre for Medical Imaging, University College London, London (United Kingdom); Arridge, Simon R [Centre for Medical Image Computing, University College London, London (United Kingdom); Hutton, Brian F [Institute of Nuclear Medicine, University College London, London (United Kingdom); Ourselin, Sébastien [Centre for Medical Image Computing, University College London, London (United Kingdom); Dementia Research Centre, University College London, London (United Kingdom)

    2014-07-29

    Simultaneous PET and MR acquisitions have now become possible with the new hybrid Biograph Molecular MR (mMR) scanner from Siemens. The purpose of this work is to create a platform for mMR 3D and 4D PET image reconstruction which would be freely accessible to the community as well as fully adjustable in order to obtain optimal images for a given research task in PET imaging. The proposed platform is envisaged to prove useful in developing novel and robust image bio-markers which could then be adapted for use on the mMR scanner.

  12. Image reconstruction of mMR PET data using the open source software STIR

    International Nuclear Information System (INIS)

    Markiewicz, Pawel; Thielemans, Kris; Burgos, Ninon; Manber, Richard; Jiao, Jieqing; Barnes, Anna; Atkinson, David; Arridge, Simon R; Hutton, Brian F; Ourselin, Sébastien

    2014-01-01

    Simultaneous PET and MR acquisitions have now become possible with the new hybrid Biograph Molecular MR (mMR) scanner from Siemens. The purpose of this work is to create a platform for mMR 3D and 4D PET image reconstruction which would be freely accessible to the community as well as fully adjustable in order to obtain optimal images for a given research task in PET imaging. The proposed platform is envisaged to prove useful in developing novel and robust image bio-markers which could then be adapted for use on the mMR scanner.

  13. 77 FR 34935 - Foreign-Trade Zone 161; Temporary/Interim Manufacturing Authority; Siemens Energy, Inc., (Wind...

    Science.gov (United States)

    2012-06-12

    ... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [Docket T-4-2012] Foreign-Trade Zone 161; Temporary/Interim Manufacturing Authority; Siemens Energy, Inc., (Wind Turbine Nacelles and Hubs); Notice of... temporary/interim manufacturing (T/IM) authority, on behalf of Siemens Energy, Inc., to manufacture wind...

  14. Five years of experience with external laundry service for alpha-contaminated protective clothing in the decommissioning period Siemens PG formerly Siemens fuel rod factory Hanau

    International Nuclear Information System (INIS)

    Raabe, E.; Hadders, R.; Wilke, M.

    2003-01-01

    The external decontamination of protective clothing is a new concept in Europe in the past, companies ran their own laundries and decontaminated their clothing themselves. Running a laundry within a nuclear facility bears a great deal of complicated problems. Firstly the operator must find suitable staffs, which has to pass the strict vetting and still not be overqualified for the job. In addition to the problem of finding and employing suitable, reliable staff the workload varies very much. Although this is not the main problem for the decommissioning project Siemens PG fuel rod factory. Nuclear power plants have to employ additional staff for their laundries during outages. (orig.)

  15. Pet Health

    Science.gov (United States)

    ... companionship and a feeling of safety to your life. Before getting a pet, think carefully about which ... Gaining or losing a lot of weight quickly Strange behavior Being sluggish and tired Trouble getting up ...

  16. Radiation monitoring of PET staff

    International Nuclear Information System (INIS)

    Trang, A.

    2004-01-01

    Full text: Positron emission tomography (PET) is becoming a common diagnostic tool in hospitals, often located in and employing staff from the Nuclear Medicine or Radiology departments. Although similar in some ways, staff in PET departments are commonly found to have the highest radiation doses in the hospital environment due to unique challenges which PET tracers present in administration as well as production. The establishment of a PET centre with a dedicated cyclotron has raised concerns of radiation protection to the staff at the WA PET Centre and the Radiopharmaceutical Production and Development (RAPID) team. Since every PET centre has differing designs and practices, it was considered important to closely monitor the radiation dose to our staff so that improvements to practices and design could be made to reduce radiation dose. Electronic dosimeters (MGP DMC 2000XB), which have a facility to log time and dose at 10 second intervals, were provided to three PET technologists and three PET nurses. These were worn in the top pocket of their lab coats throughout a whole day. Each staff member was then asked to note down their duties throughout the day and also note the time they performed each duty. The duties would then correlate with the dose with which the electronic monitor recorded and an estimate of radiation dose per duty could be given. Also an estimate of the dose per day to each staff member could be made. PET nurses averaged approximately 20 μ8v per day getting their largest dose from caring for occasional problematic patients. Smaller doses of a 1-2 μ8v were recorded for injections and removing cannulas. PET technologists averaged approximately 15 μ8v per day getting their largest dose of 1-5μ8v mainly from positioning of patients and sometimes larger doses due to problematic patients. Smaller doses of 1-2 μ5v were again recorded for injections and removal of cannulas. Following a presentation given to staff, all WA PET Centre and RAPID staff

  17. Activity concentration measurements using a conjugate gradient (Siemens xSPECT) reconstruction algorithm in SPECT/CT.

    Science.gov (United States)

    Armstrong, Ian S; Hoffmann, Sandra A

    2016-11-01

    The interest in quantitative single photon emission computer tomography (SPECT) shows potential in a number of clinical applications and now several vendors are providing software and hardware solutions to allow 'SUV-SPECT' to mirror metrics used in PET imaging. This brief technical report assesses the accuracy of activity concentration measurements using a new algorithm 'xSPECT' from Siemens Healthcare. SPECT/CT data were acquired from a uniform cylinder with 5, 10, 15 and 20 s/projection and NEMA image quality phantom with 25 s/projection. The NEMA phantom had hot spheres filled with an 8 : 1 activity concentration relative to the background compartment. Reconstructions were performed using parameters defined by manufacturer presets available with the algorithm. The accuracy of activity concentration measurements was assessed. A dose calibrator-camera cross-calibration factor (CCF) was derived from the uniform phantom data. In uniform phantom images, a positive bias was observed, ranging from ∼6% in the lower count images to ∼4% in the higher-count images. On the basis of the higher-count data, a CCF of 0.96 was derived. As expected, considerable negative bias was measured in the NEMA spheres using region mean values whereas positive bias was measured in the four largest NEMA spheres. Nonmonotonically increasing recovery curves for the hot spheres suggested the presence of Gibbs edge enhancement from resolution modelling. Sufficiently accurate activity concentration measurements can easily be measured on images reconstructed with the xSPECT algorithm without a CCF. However, the use of a CCF is likely to improve accuracy further. A manual conversion of voxel values into SUV should be possible, provided that the patient weight, injected activity and time between injection and imaging are all known accurately.

  18. A Monte Carlo simulation study of the impact of novel scintillation crystals on performance characteristics of PET scanners

    DEFF Research Database (Denmark)

    Ghabrial, Amir; Franklin, Daniel; Zaidi, Habib

    2018-01-01

    Objective: The purpose of this study is to validate a Monte Carlo simulation model for the clinical Siemens Biograph mCT PET scanner using the GATE simulation toolkit, and to evaluate the performance of six different scintillation materials in this model using the National Electrical Manufactures...

  19. Pet Allergy Quiz

    Science.gov (United States)

    ... Treatments ▸ Allergies ▸ Pet Allergy ▸ Pet Allergy Quiz Share | Pet Allergy Quiz More than half of U.S. households ... cat family. Yet, millions of people suffer from pet allergies. Take this quiz to test your knowledge ...

  20. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs

  1. Positron Emission Tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  2. Positron Emission Tomography (PET)

    Science.gov (United States)

    Welch, M. J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.

  3. Dedicated education unit: student perspectives.

    Science.gov (United States)

    Nishioka, Vicki M; Coe, Michael T; Hanita, Makoto; Moscato, Susan R

    2014-01-01

    The study compared students' perceptions of their clinical learning experiences in a dedicated education unit (DEU) with their experiences in traditional clinical education. Unlike traditional academic-instructor models, expert nurses in the DEU provide clinical education to students with faculty support. This repeated measures design used student surveys, supplemented by focus group data. Students were more likely to agree that their clinical learning experience was high quality and they had a consistent mentoring relationship during DEU rotations. Students also reported the quality of the unit's learning environment, the leadership style of the nurse manager, and the nursing care on the unit was more favorable in DEUs than traditional units. Consistent with their changed role in DEUs, faculty members were less active in helping students integrate theory and practice. These findings provide additional evidence of the value that the DEU model contributes to high-quality clinical education.

  4. Siemens HELICON

    International Nuclear Information System (INIS)

    Reichert, T.; Bittner, G.; Heinzelmann, K.G.; Solner, L.; Vetter, J.

    1988-01-01

    A new superconducting 2 tesla magnet for whole-body magnetic resonance imaging and spectroscopy has been developed as a serial product. The HELICON magnet has the following features: Cryogen losses including ramping losses are eliminated due to helium refrigerator cooling. The magnet size is moderate despite of a large warm bore. The magnet can be ramped in 25 min from zero field to 2 Tesla. The field stability is 5 ppm/hour immediately after ramping and settles to 1 ppm/hour within 1 hour. Shimmed homogeneity band width is less than +- 5 ppm on a 50 cm diameter spherical volume using an 11-plane field plot. The magnet can be combined with a specially designed iron-yoke shield which reduces the extension of the 0.5 tesla stray field line at 2 tesla operating field to 7.4 m axially and 5.6 m radially. Cold shipment of the magnet is possible without special precautions

  5. PET/MRI for Oncologic Brain Imaging

    DEFF Research Database (Denmark)

    Rausch, Ivo; Rischka, Lucas; Ladefoged, Claes N

    2017-01-01

    The aim of this study was to compare attenuation-correction (AC) approaches for PET/MRI in clinical neurooncology.Methods:Forty-nine PET/MRI brain scans were included: brain tumor studies using18F-fluoro-ethyl-tyrosine (18F-FET) (n= 31) and68Ga-DOTANOC (n= 7) and studies of healthy subjects using18...... by Siemens Healthcare). As a reference, AC maps were derived from patient-specific CT images (CTref). PET data were reconstructed using standard settings after AC with all 4 AC methods. We report changes in diagnosis for all brain tumor patients and the following relative differences values (RDs...... of the whole brain and 10 anatomic regions segmented on MR images.Results:For brain tumor imaging (A and B), the standard PET-based diagnosis was not affected by any of the 3 MR-AC methods. For A, the average RDs of SUVmeanwere -10%, -4%, and -3% and of the VOIs 1%, 2%, and 7% for DIXON, UTE, and BD...

  6. Pushing forward IGCC and CO{sub 2}-free power plant technology at Siemens

    Energy Technology Data Exchange (ETDEWEB)

    Hannemann, E.; Vortmeyer, N.; Zimmermann, G. [Siemens AG, Erlangen (Germany). Power Generation

    2004-07-01

    Siemens Power Generation has entered into several R & D projects within the European Commissions' 5th and 6th Framework Programs. One objective of those projects is to develop advanced modular IGCC concepts for in-refinery energy and hydrogen supply. Additional projects are dealing with pre- and post-combustion decarbonisation technologies, which should achieve high carbon dioxide capture at low costs. In parallel, the development of advanced combustion systems including enhanced fuel flexibility and application of low BTU gases in the highly efficient Siemens V94.3A gas turbine are in progress. In further step the technology for burning hydrogen enriched gases resulting from decarbonisation in CO{sub 2} free power plants will be provided. This report documents the current status of these activities. 9 refs., 12 figs.

  7. Siemens sees a future for IGCC - and now it has the technology

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, C.; Hannemann, F. [Siemens Fuel Gasification Technology, Freiberg (Germany)

    2007-10-15

    About 18 months ago Siemens became a key player in the gasification business through its acquisition of Freiberg based Future Energy and its GSP entrained flow technology, now called SFG (Siemens Fuel Gasification). Developed at Schwarze Pumpe in Eastern Germany over many years, a particular attraction of the process is its ability to use low rank fuels such as lignite, with a robust gasifier wall concept a 'cooling screen' that avoids the use of troublesome refractories. The article explains the SFG gasifier technology. It is ideally suited for coal-fueled IGCC power plants with integrated CO{sub 2} capture, especially for low-rank fuels. SFG has been ordered or pre-selected for a number of projects in China, North America and elsewhere. 5 figs.

  8. Steam generators secondary side chemical cleaning at Point Lepreau using the Siemen's high temperature process

    International Nuclear Information System (INIS)

    Verma, K.; MacNeil, C.; Odar, S.

    1996-01-01

    The secondary sides of all four steam generators at the Point Lepreau Nuclear Generating Stations were cleaned during the 1995 annual outage run-down using the Siemens high temperature chemical cleaning process. Traditionally all secondary side chemical cleaning exercises in CANDU as well as the other nuclear power stations in North America have been conducted using a process developed in conjunction with the Electric Power Research Institute (EPRI). The Siemens high temperature process was applied for the first time in North America at the Point Lepreau Nuclear Generating Station (PLGS). The paper discusses experiences related to the pre and post award chemical cleaning activities, chemical cleaning application, post cleaning inspection results and waste handling activities. (author)

  9. Reproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System

    Directory of Open Access Journals (Sweden)

    Martin L. Lassen

    2017-07-01

    Full Text Available The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic parameters as a function of PET system choice have been investigated. Five healthy volunteers underwent dynamic (R-[11C]verapamil imaging on the same day using a GE-Advance (PET-only and a Siemens Biograph mMR system (PET/MR. PET-emission data were reconstructed using a transmission-based attenuation correction (AC map (PET-only, whereas a standard MR-DIXON as well as a low-dose CT AC map was applied to PET/MR emission data. Kinetic modeling based on arterial blood sampling was performed using a 1-tissue-2-rate constant compartment model, yielding kinetic parameters (K1 and k2 and distribution volume (VT. Differences for parametric values obtained in the PET-only and the PET/MR systems were analyzed using a 2-way Analysis of Variance (ANOVA. Comparison of DIXON-based AC (PET/MR with emission data derived from the PET-only system revealed average inter-system differences of −33 ± 14% (p < 0.05 for the K1 parameter and −19 ± 9% (p < 0.05 for k2. Using a CT-based AC for PET/MR resulted in slightly lower systematic differences of −16 ± 18% for K1 and −9 ± 10% for k2. The average differences in VT were −18 ± 10% (p < 0.05 for DIXON- and −8 ± 13% for CT-based AC. Significant systematic differences were observed for kinetic parameters derived from emission data obtained from PET/MR and PET-only imaging due to different standard AC methods employed. Therefore, a transfer of imaging protocols from PET-only to PET/MR systems is not straightforward without application of proper correction methods.Clinical Trial Registration:www.clinicaltrialsregister.eu, identifier 2013-001724-19

  10. Agile working as a key for diversity: the Siemens office project

    OpenAIRE

    S. Cuomo; A. Mapelli

    2014-01-01

    Following directives from corporate headquarters in 2011, the Real Estate Division of Siemens Italia faced the challenge of implementing significant changes in work organisation, which arose from the need to consolidate all the Milan-based offices into a single location; a Green Building, characterised by a reduction of the available floor space, compared to the sum of the local offices. However, this reorganisation was perceived as stimulus to think of this change, not only in relation to sp...

  11. 3D Surface Realignment Tracking for Medical Imaging: A Phantom Study with PET Motion Correction

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Paulsen, Rasmus Reinhold; Jensen, Rasmus Ramsbøl

    2011-01-01

    We present a complete system for motion correction in high resolution brain positron emission tomography (PET) imaging. It is based on a compact structured light scanner mounted above the patient tunnel of the Siemens High Resolution Research Tomograph PET brain scanner. The structured light system...... is equipped with a near infrared diode and uses phase-shift interferometry to compute 3D representations of the forehead of the patient. These 3D point clouds are progressively aligned to a reference surface and thereby giving the head pose changes. The estimated pose changes are used to reposition a sequence...... of recon- structed PET frames. To align the structured light system with the PET coordinate system a novel registration algorithm based on the PET trans- mission scan and an initial surface has been developed. The performance of the complete setup has been evaluated using a custom made phantom based...

  12. Automatic extraction of forward stroke volume using dynamic 11C-acetate PET/CT

    DEFF Research Database (Denmark)

    Harms, Hans; Tolbod, Lars Poulsen; Hansson, Nils Henrik

    Objectives: Dynamic PET with 11C-acetate can be used to quantify myocardial blood flow and oxidative metabolism, the latter of which is used to calculate myocardial external efficiency (MEE). Calculation of MEE requires forward stroke volume (FSV) data. FSV is affected by cardiac loading conditions......, potentially introducing bias if measured with a separate modality. The aim of this study was to develop and validate methods for automatically extracting FSV directly from the dynamic PET used for measuring oxidative metabolism. Methods: 16 subjects underwent a dynamic 27 min PET scan on a Siemens Biograph...... TruePoint 64 PET/CT scanner after bolus injection of 399±27 MBq of 11C-acetate. The LV-aortic time-activity curve (TAC) was extracted automatically from dynamic PET data using cluster analysis. The first-pass peak was derived by automatic extrapolation of the down-slope of the TAC. FSV...

  13. Innovative maintenance concept 0f Siemens Energy Service. Turbine documentation in an online catalogue; Innovatives Instandhaltungskonzept bei Siemens Energy Service. Turbinendokumentation als Onlinekatalog

    Energy Technology Data Exchange (ETDEWEB)

    Bitzer, Gerd [Wessendorf Software and Consulting, Berlin (Germany); Stass, Georg [Tema Technologie Marketing AG, Berlin (Germany)

    2010-10-04

    For optimization of its maintenance services, Siemens Energy Services has drawn up an online catalogue as a standardized solution for turbine documentation for customers and service technicians. The new catalogue offers power plant operators internet access to the current documentation of service-relevant replacement parts for machinery. The catalogues are based on SAP data using the Linkone software; each of them has up to 3,000 material items and 1,000 illustrations of replacement parts depending on the type of turbine. The project partner was the Berlin consulting service Wessendorf Software + Consulting (WSC) who have vast experience in the implementation of international catalogue and documentation projects with SAP software. After a project period of 15 months, the innovative solution was implemented in April 2010 and then launched in the market. (orig.)

  14. 3rd August 2010 - CEO Siemens Healthcare Sector, Chief Technology Officer, Head of Corporate Technology, Member of Siemens AG Managing Board, Germany, H. Requardt, signing the guest book with CERN Director-General R. Heuer

    CERN Multimedia

    Maximilien Brice

    2010-01-01

    CERN-HI-1008148 11: H. von Dewitz in the ATLAS Visitor centre with Collaboration member M. Hauschild (left) and Former IT Department Head W. von Rüden (right) CERN-HI-1008148 18 : Head of Innovation and Systems Projects, Siemens Healthcare Sector O. Heid (left) in the ATLAS Visitor centre with Collaboration member M. Hauschild. CERN-HI-1008148: in the ATLAS visitor centre, from left to right: Former IT Department Head W. von Rüden; ATLAS Collaboration P. Mättig; CEO Siemens Healthcare Sector, Chief Technology Officer, Head of Corporate Technology, Member of Siemens AG Managing Board, Germany, H. Requardt; Head of Innovation and Systems Projects, Siemens Healthcare Sector O. Heid; H. von Dewitz; ATLAS Collaboration member M. Hauschild.

  15. Hyperpolarized 13C-MRSI and PET (hyperPET) in an Osteomyelitis Pig Model

    DEFF Research Database (Denmark)

    Rahbek, Sofie; Gutte, Henrik; Johannesen, Helle H

    2017-01-01

    -PET for imaging of infection. METHODS: Three pigs were inoculated with S. aureusbacteria in the right tibia and saline in the left tibial bone. FDG-PET, 1H-MRI and 13C-MRSI was performed using a clinical whole-body PET/MR system (Siemens Biograph mMR, Erlangen, Germany). Hyperpolarized13C-pyruvate was prepared...... was observed outside the right (infected bone) on 1H-MRI and confirmed by histopathology. In the abscess the 13C-lactate to 13C-pyruvate ratio was increased as compared to the inflammatory region of the control leg. 18F-FDG uptake showed no clear trend when comparing abscess versus inflammation, but showed...

  16. SIEMENS ADVANCED QUANTRA FTICR MASS SPECTROMETER FOR ULTRA HIGH RESOLUTION AT LOW MASS

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, W; Laura Tovo, L

    2008-07-08

    The Siemens Advanced Quantra Fourier Transform Ion Cyclotron Resonance (FTICR) mass spectrometer was evaluated as an alternative instrument to large double focusing mass spectrometers for gas analysis. High resolution mass spectrometers capable of resolving the common mass isomers of the hydrogen isotopes are used to provide data for accurate loading of reservoirs and to monitor separation of tritium, deuterium, and helium. Conventional double focusing magnetic sector instruments have a resolution that is limited to about 5000. The Siemens FTICR instrument achieves resolution beyond 400,000 and could possibly resolve the tritium ion from the helium-3 ion, which differ by the weight of an electron, 0.00549 amu. Working with Y-12 and LANL, SRNL requested Siemens to modify their commercial Quantra system for low mass analysis. To achieve the required performance, Siemens had to increase the available waveform operating frequency from 5 MHz to 40 MHz and completely redesign the control electronics and software. However, they were able to use the previous ion trap, magnet, passive pump, and piezo-electric pulsed inlet valve design. NNSA invested $1M in this project and acquired four systems, two for Y-12 and one each for SRNL and LANL. Siemens claimed a $10M investment in the Quantra systems. The new Siemens Advanced Quantra demonstrated phenomenal resolution in the low mass range. Resolution greater than 400,000 was achieved for mass 2. The new spectrometer had a useful working mass range to 500 Daltons. However, experiments found that a continuous single scan from low mass to high was not possible. Two useful working ranges were established covering masses 1 to 6 and masses 12 to 500 for our studies. A compromise performance condition enabled masses 1 to 45 to be surveyed. The instrument was found to have a dynamic range of about three orders of magnitude and quantitative analysis is expected to be limited to around 5 percent without using complex fitting algorithms

  17. Value of integrated PET/CT in clinical staging of patients with lung cancer

    International Nuclear Information System (INIS)

    Zhao Jun; Guan Yihui; Zuo Chuantao; Hua Fengchun; Lin Xiangtong

    2004-01-01

    Objectives: The purpose of this study was to evaluate the value of combined fluorine-18 fluorodeoxyglucose positron emission tomography and computed tomography (FDG PET/CT) in patients with lung cancer, and to compare the results of PET/CT with those of FDG PET and CT alone. Methods: Forty-two patients were studied in this group. 3D whole body images were acquired using Siemens Biograph Sensetionl6 PET/CT scanner. Attenuation corrected PET images, CT and fusion images were interpreted. Reports were compared for each patient including identified the number of lesions, their anatomical localization and certainty of diagnosis. Results: PET/CT increased the number of lesions reported as being definitely abnormal or normal (+22%). In 12 patients (28.6%), the PET/CT report positively impacted surgical management when compared to the PET report alone. 6 patients were correctly downstaged negating further treatment or imaging, 3 patient was upstaged to inoperable and in another 3 ones improved localization by PET/CT led to an altered surgical incision with decreased morbidity. Lesion-based evaluation showed sensitivity for regional lymph node involvement of 61% for CT alone, 88% for FDG PET alone, and 96% for integrated PET/CT imaging respectively. In addition, PET/CT could identify some benign disease, including lung tuberculosis, cyst of liver and kidney, calculus etc. Conclusion: PET/CT improves anatomical localization and increases the certainty in reporting abnormal and normal lesions. PET/CT imaging is superior to CT alone and has additional benefit over FDG PET alone, and is accurate in clinical staging for lung cancer. (authors)

  18. Value of {sup 11}C-choline PET and PET/CT in patients with suspected prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Scher, Bernhard; Albinger, Wolfram; Tiling, Reinhold; Gildehaus, Franz-Josef; Dresel, Stefan [University of Munich, Department of Nuclear Medicine, Munich (Germany); Seitz, Michael [University of Munich, Department of Urology, Munich (Germany); Scherr, Michael; Becker, Hans-Christoph [University of Munich, Department of Radiology, Munich (Germany); Souvatzogluou, Michael; Wester, Hans-Juergen [Technical University of Munich, Department of Nuclear Medicine, Munich (Germany)

    2007-01-15

    The value and limitations of {sup 11}C-choline PET and PET/CT for the detection of prostate cancer remain controversial. The aim of this study was to investigate the diagnostic efficacy of {sup 11}C-choline PET and PET/CT in a large group of patients with suspected prostate cancer. Fifty-eight patients with clinical suspicion of prostate cancer underwent {sup 11}C-choline PET (25/58, Siemens ECAT Exact HR+) or PET/CT (33/58, Philips Gemini) scanning. On average, 500 MBq of {sup 11}C-choline was administered intravenously. Studies were interpreted by raters blinded to clinical information and other diagnostic procedures. Qualitative image analysis as well as semiquantitative SUV measurement was carried out. The reference standard was histopathological examination of resection specimens or biopsy. Prevalence of prostate cancer in this selected patient population was 63.8% (37/58). {sup 11}C-choline PET and PET/CT showed a sensitivity of 86.5% (32/37) and a specificity of 61.9% (13/21) in the detection of the primary malignancy. With regard to metastatic spread, PET showed a per-patient sensitivity of 81.8% (9/11) and produced no false positive findings. Based on our findings, differentiation between benign prostatic changes, such as benign prostatic hyperplasia or prostatitis, and prostate cancer is feasible in the majority of cases when image interpretation is primarily based on qualitative characteristics. SUV{sub max} may serve as guidance. False positive findings may occur due to an overlap of {sup 11}C-choline uptake between benign and malignant processes. By providing functional information regarding both the primary malignancy and its metastases, {sup 11}C-choline PET may prove to be a useful method for staging prostate cancer. (orig.)

  19. Monte Carlo simulations in small animal PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Branco, Susana [Universidade de Lisboa, Faculdade de Ciencias, Instituto de Biofisica e Engenharia Biomedica, Lisbon (Portugal)], E-mail: susana.silva@fc.ul.pt; Jan, Sebastien [Service Hospitalier Frederic Joliot, CEA/DSV/DRM, Orsay (France); Almeida, Pedro [Universidade de Lisboa, Faculdade de Ciencias, Instituto de Biofisica e Engenharia Biomedica, Lisbon (Portugal)

    2007-10-01

    This work is based on the use of an implemented Positron Emission Tomography (PET) simulation system dedicated for small animal PET imaging. Geant4 Application for Tomographic Emission (GATE), a Monte Carlo simulation platform based on the Geant4 libraries, is well suited for modeling the microPET FOCUS system and to implement realistic phantoms, such as the MOBY phantom, and data maps from real examinations. The use of a microPET FOCUS simulation model with GATE has been validated for spatial resolution, counting rates performances, imaging contrast recovery and quantitative analysis. Results from realistic studies of the mouse body using {sup -}F and [{sup 18}F]FDG imaging protocols are presented. These simulations include the injection of realistic doses into the animal and realistic time framing. The results have shown that it is possible to simulate small animal PET acquisitions under realistic conditions, and are expected to be useful to improve the quantitative analysis in PET mouse body studies.

  20. PET and SPECT in psychiatry

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Otte, Andreas; Vries, Erik F.J. de; Waarde, Aren van

    2014-01-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  1. PET and SPECT in psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium); Otte, Andreas [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-09-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  2. Generating and distributing electricity economically and in large amounts for generations. Siemens - a synonym of electrical industry

    International Nuclear Information System (INIS)

    Feldenkirchen, W.

    1997-01-01

    The development of electrical engineering and the history of the Siemens company have been closely interrelated since their beginnings. Since the late 19th century, the electrical industry, by constantly extending its range of products, has turned into a sector of economy with an international reputation. Under the paradigm of assuming technological leadership, or co-leadership, in the development of electrical engineering world-wide, Siemens has had its share in this process. (orig.) [de

  3. Intra-individual comparison of F-18-FLT PET and F-18 FET PET in brain tumor patients

    International Nuclear Information System (INIS)

    Kim, S.; Cheon, G.J.; Cho, Y.S.; Kwak, H.S.; Lee, C.H.; Choi, C.W.; Lim, S.M.

    2004-01-01

    Full text: The nucleoside analogue 18F-3'-deoxy-3'-fluorothymidine (FLT) for cellular proliferation and the amino acid analogue O- (2'18F-fluoroethyl)-L-tyrosine (FET) are recently developed PET-tracer for tumor imaging. Previous studies have demonstrated that the diagnostic ability of FET PET better than FDG PET in patient with newly diagnosed or recurrent brain tumors after radiation therapy. To compare findings on FLT PET with FET PET, we prospectively undertook FLT, FET and FDG PET in same patient with suspected primary/metastatic and recurrent brain tumors. Seventeen studies (FLT +FET + FDG: 13, FLT+FDG: 3, FLT +FET: 1) in 16 consecutive patients (47 ± 8.3 years, M: F 10: 6) with brain tumor (3 for initial diagnosis, 6 for therapeutic response, 6 for detecting recurrence, 1 for diagnosis and recurrence both) were included. Brain tumors were 14 gliomas (6 high-grade, 9 low-grade by the WHO classification), 2 metastatic brain tumors and 1 CNS lymphoma. 18F-FDG, FLT and FET PET were performed within two weeks. Attenuation-corrected brain images were acquired 30 minutes after injection of 370-555 MBq FDG, FLT and FET with a dedicated PET scanner (ECAT HR+ scanner, Siemens-CTI, Knoxville, Tenn., USA). Maximum SUV (max SUV) and relative uptake defined by FLT and FET accumulation within the tumor in relation to a contra lateral control region (max SUV for tumor/mean SUV for contra lateral normal gray matter) were calculated. A total of 26 tumor foci (26 on FLT and FDG, 22 on FET) in 17 studies were analysed. In most of tumor foci (20 of 22) FLT and FET PET images showed a similar extent of tumor activity. In 2 tumor foci discrepant findings were noticed; intense FLT uptake with negative FLT uptake in primary CNS lymphoma and negative FLT uptake with mild FET uptake in low-grade astrocytoma. Overall positive FLT, FET and FDG uptakes were 85 % (22/26), 90 % (18/ 20) and 58 % (15/26) respectively. Max SUV and relative FLT/FET uptake: The mean max SUV of FLT (0.97 ± 0

  4. Small animal PET: aspects of performance assessment

    International Nuclear Information System (INIS)

    Weber, Simone; Bauer, Andreas

    2004-01-01

    Dedicated small animal positron emission tomography (PET) systems are increasingly prevalent in industry (e.g. for preclinical drug development) and biological research. Such systems permit researchers to perform animal studies of a longitudinal design characterised by repeated measurements in single animals. With the advent of commercial systems, scanners have become readily available and increasingly popular. As a consequence, technical specifications are becoming more diverse, making scanner systems less broadly applicable. The investigator has, therefore, to make a decision regarding which type of scanner is most suitable for the intended experiments. This decision should be based on gantry characteristics and the physical performance. The first few steps have been taken towards standardisation of the assessment of performance characteristics of dedicated animal PET systems, though such assessment is not yet routinely implemented. In this review, we describe current methods of evaluation of physical performance parameters of small animal PET scanners. Effects of methodologically different approaches on the results are assessed. It is underscored that particular attention has to be paid to spatial resolution, sensitivity, scatter fraction and count rate performance. Differences in performance measurement methods are described with regard to commercially available systems, namely the Concorde MicroPET systems P4 and R4 and the quad-HIDAC. Lastly, consequences of differences in scanner performance parameters are rated with respect to applications of small animal PET. (orig.)

  5. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  6. PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation

    Energy Technology Data Exchange (ETDEWEB)

    Espana, S; Herraiz, J L; Vicente, E; Udias, J M [Grupo de Fisica Nuclear, Departmento de Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid, Madrid (Spain); Vaquero, J J; Desco, M [Unidad de Medicina y CirugIa Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain)], E-mail: jose@nuc2.fis.ucm.es

    2009-03-21

    Monte Carlo simulations play an important role in positron emission tomography (PET) imaging, as an essential tool for the research and development of new scanners and for advanced image reconstruction. PeneloPET, a PET-dedicated Monte Carlo tool, is presented and validated in this work. PeneloPET is based on PENELOPE, a Monte Carlo code for the simulation of the transport in matter of electrons, positrons and photons, with energies from a few hundred eV to 1 GeV. PENELOPE is robust, fast and very accurate, but it may be unfriendly to people not acquainted with the FORTRAN programming language. PeneloPET is an easy-to-use application which allows comprehensive simulations of PET systems within PENELOPE. Complex and realistic simulations can be set by modifying a few simple input text files. Different levels of output data are available for analysis, from sinogram and lines-of-response (LORs) histogramming to fully detailed list mode. These data can be further exploited with the preferred programming language, including ROOT. PeneloPET simulates PET systems based on crystal array blocks coupled to photodetectors and allows the user to define radioactive sources, detectors, shielding and other parts of the scanner. The acquisition chain is simulated in high level detail; for instance, the electronic processing can include pile-up rejection mechanisms and time stamping of events, if desired. This paper describes PeneloPET and shows the results of extensive validations and comparisons of simulations against real measurements from commercial acquisition systems. PeneloPET is being extensively employed to improve the image quality of commercial PET systems and for the development of new ones.

  7. PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation

    International Nuclear Information System (INIS)

    Espana, S; Herraiz, J L; Vicente, E; Udias, J M; Vaquero, J J; Desco, M

    2009-01-01

    Monte Carlo simulations play an important role in positron emission tomography (PET) imaging, as an essential tool for the research and development of new scanners and for advanced image reconstruction. PeneloPET, a PET-dedicated Monte Carlo tool, is presented and validated in this work. PeneloPET is based on PENELOPE, a Monte Carlo code for the simulation of the transport in matter of electrons, positrons and photons, with energies from a few hundred eV to 1 GeV. PENELOPE is robust, fast and very accurate, but it may be unfriendly to people not acquainted with the FORTRAN programming language. PeneloPET is an easy-to-use application which allows comprehensive simulations of PET systems within PENELOPE. Complex and realistic simulations can be set by modifying a few simple input text files. Different levels of output data are available for analysis, from sinogram and lines-of-response (LORs) histogramming to fully detailed list mode. These data can be further exploited with the preferred programming language, including ROOT. PeneloPET simulates PET systems based on crystal array blocks coupled to photodetectors and allows the user to define radioactive sources, detectors, shielding and other parts of the scanner. The acquisition chain is simulated in high level detail; for instance, the electronic processing can include pile-up rejection mechanisms and time stamping of events, if desired. This paper describes PeneloPET and shows the results of extensive validations and comparisons of simulations against real measurements from commercial acquisition systems. PeneloPET is being extensively employed to improve the image quality of commercial PET systems and for the development of new ones.

  8. Christ-Siemens-Touraine Syndrome: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Sepideh Mokhtari

    2012-01-01

    Full Text Available Ectodermal dysplasia is a rare disorder with defects in two or more of the following structures: the teeth and the skin and its appendages including hair, nails, eccrine, and sebaceous glands. Anhidrotic ectodermal dysplasia is the most common type of disease. This rare disorder, also known as Christ-Siemens-Touraine syndrome, manifests as a triad of hypotrichosis, asteatosis, and anhidrosis. In view of the rarity of this entity, a classical case of anhidrotic ectodermal dysplasia is reported. We have also provided a review of recent investigations in the area of dental abnormalities in this syndrome.

  9. Adequate engineering for lowering the frequency of initiating events at Siemens/KWU

    International Nuclear Information System (INIS)

    Gremm, O.

    1988-01-01

    The analysis of TMI and Chernobyl events shows weak points and deficits in the field of preventive safety features. This should not be forgotten during the ongoing discussion on severe accidents. Therefore the paper explains special preventive safety features which were the results of the development of Siemens/KWU reactor technology. With respect to the present discussion on new reactor concepts special attention is given to the inherent and passive safety features and the engineering which results in low core melt frequency. Such an analysis leads to knowledge modules which are based on experience during licensing procedures and plant operation and should be the starting points for reactor technology of the future

  10. Sustainable cities: A research by McKinsey and Siemens on sustainable development in London

    Energy Technology Data Exchange (ETDEWEB)

    Denig, Stefan

    2010-09-15

    The research Sustainable Urban Infrastructure conducted by McKinsey and Company and Siemens assesses technological levers of varying effectiveness, and with different cost implications, which can all contribute to greater environmental sustainability in cities, drawing in particular on the example of London. It's the first comprehensive research focusing on technological and economic implications of a city's infrastructure management in the fields of energy, buildings and transportation. The encouraging message is that many of the levers to reduce energy consumption and CO2 emissions in urban agglomerations not only help protect the environment, but also pay back from an economic point of view.

  11. Advances in and prospects for development of high-temperature superconductor rotating machines at Siemens

    International Nuclear Information System (INIS)

    Neumueller, H W; Nick, W; Wacker, B; Frank, M; Nerowski, G; Frauenhofer, J; Rzadki, W; Hartig, R

    2006-01-01

    We report on the successful manufacture and testing of the Siemens 400 kVA HTS synchronous motor, which has been in operation for over 3 years, and on the progress of the 4 MVA synchronous motor/generator, which has been manufactured and is now in a phase of extended testing. Furthermore, the benefits of HTS machines will be discussed with emphasis on applications in ships. The development of future marketable products will be strongly dependent on the progress of secondary technologies, such as wire performance and efficient cost-effective refrigerators

  12. Application of NX Siemens PLM software in educational process in preparing students of engineering branch

    Science.gov (United States)

    Sadchikova, G. M.

    2017-01-01

    This article discusses the results of the introduction of computer-aided design NX by Siemens Plm Software to the classes of a higher education institution. The necessity of application of modern information technologies in teaching students of engineering profile and selection of a software product is substantiated. The author describes stages of the software module study in relation to some specific courses, considers the features of NX software, which require the creation of standard and unified product databases. The article also gives examples of research carried out by the students with the various software modules.

  13. Whole-body PET/MRI: The effect of bone attenuation during MR-based attenuation correction in oncology imaging

    DEFF Research Database (Denmark)

    Aznar, M.C.; Sersar, Rachida; Saabye, J.

    2014-01-01

    patients referred for a PET/CT were injected with either [18F]-FDG or [18F]-NaF and imaged on PET/CT (Biograph TruePoint/mCT, Siemens) and PET/MRI (mMR, Siemens) following a standard single-injection, dual-imaging clinical WB-protocol. Routine MR-AC was based on in-/opposed-phase MR imaging (orgMR-AC). PET...... and then investigate different strategies to account for bone tissue in clinical PET/MR imaging. To this purpose, bone tissue representation was extracted from separate CT images, and different bone representations were simulated from hypothetically derived MR-based bone classifications. Methods: Twenty oncology.......3%) and lowest for spongCT (–2.2%, range: 0.0% to –13.7%). Conclusions: In PET/MR imaging using standard MR-AC PET uptake values in soft lesions and bone lesions are underestimated by about 10%. In individual patients this bias can be as high as 22%, which is significant during clinical follow-up exams. If bone...

  14. Healthy Pets and People

    Science.gov (United States)

    ... prevent the spread of germs between pets and people. Keep pets and their supplies out of the kitchen, and ... a local wildlife rehabilitation facility. More Information Healthy Pets Healthy People Clean Hands Save Lives! Stay Healthy at Animal ...

  15. Automatic extraction of forward stroke volume using dynamic PET/CT

    DEFF Research Database (Denmark)

    Harms, Hans; Tolbod, Lars Poulsen; Hansson, Nils Henrik

    Background: Dynamic PET can be used to extract forward stroke volume (FSV) by the indicator dilution principle. The technique employed can be automated and is in theory independent on the tracer used and may therefore be added to any dynamic cardiac PET protocol. The aim of this study...... was to validate automated methods for extracting FSV directly from dynamic PET studies for two different tracers and to examine potential scanner hardware bias. Methods: 21 subjects underwent a dynamic 27 min 11C-acetate PET scan on a Siemens Biograph TruePoint 64 PET/CT scanner (scanner I). In addition, 8...... subjects underwent a dynamic 6 min 15O-water PET scan followed by a 27 min 11C-acetate PET scan on a GE Discovery ST PET/CT scanner (scanner II). The LV-aortic time-activity curve (TAC) was extracted automatically from dynamic PET data using cluster analysis. The first-pass peak was isolated by automatic...

  16. Usefulness of Integrated PET/MRI in Head and Neck Cancer: A Preliminary Study

    International Nuclear Information System (INIS)

    Lee, Soo Jin; Seo, Hyo Jung; Cheon, Gi Jeong; Kim, Ji Hoon; Kim, E. Edmund; Kang, Keon Wook; Paeng, Jin Chul; Chung, Junekey; Lee, Dong Soo

    2014-01-01

    The new modality of an integrated positron emission tomography/magnetic resonance imaging (PET/MRI) has recently been introduced but not validated. Our objective was to evaluate clinical performance of 18 F-fluoro-2-deoxyglucose ( 18 F-FDG) PET/MRI in patients with head and neck cancer. This retrospective study was conducted between January 2013 and February 2013. Ten patients (eight men, two women; mean age, 61.4±13.4 years) with histologically proven head and neck tumors were enrolled.Whole-body PET/MRI and regional positron emission tomography (PET) with dedicated MRI were sequentially obtained. Maximum standardized uptake value (SUVmax), SUVmean, metabolic tumor volume, total lesion glycolysis and contrast enhancement were analyzed. A total of ten whole-body positron emission tomography (PET), ten regional positron emission tomography (PET), ten dedicated MRI and ten regional PET/gadolinium-enhanced T1-weighted (Gd)-MRI images were analyzed for initial staging. Two nuclear medicine physicians analyzed positron emission tomography (PET) and PET/MRI with a consensus. One radiologist analyzed dedicated MRI. The primary lesions and number of metastatic lymph nodes analyzed from each image were compared. Eight patients were diagnosed with head and neck cancer (one tongue cancer, four tonsillar cancers, one nasopharyngeal cancer and two hypopharyngeal cancers) by histological diagnosis. Two benign tumors (pleomorphic adenoma and Warthin tumor) were diagnosed with surgical operation. Whole-body positron emission tomography (PET) and regional positron emission tomography (PET) attenuated by MRI showed good image quality for the lesion detection. Whole-body positron emission tomography (PET) and regional positron emission tomography (PET) detected ten primary sites and compensated for a missed lesion on dedicated MRI. A discordant number of suspicious lymph node metastases was noted according to the different images; 22, 16, 39 and 40 in the whole-body positron

  17. Geometric calibration between PET scanner and structured light scanner

    DEFF Research Database (Denmark)

    Kjer, Hans Martin; Olesen, Oline Vinter; Paulsen, Rasmus Reinhold

    2011-01-01

    Head movements degrade the image quality of high resolution Positron Emission Tomography (PET) brain studies through blurring and artifacts. Manny image reconstruction methods allows for motion correction if the head position is tracked continuously during the study. Our method for motion tracking...... is a structured light scanner placed just above the patient tunnel on the High Resolution Research Tomograph (HRRT, Siemens). It continuously registers point clouds of a part of the patient's face. The relative motion is estimated as the rigid transformation between frames. A geometric calibration between...

  18. Climate Change Mitigation Technologies: the Siemens Roadmap to Carbon Capture and Storage

    Energy Technology Data Exchange (ETDEWEB)

    Voges, K.

    2007-07-01

    A full range of technology options will have to be deployed until 2025 to get the global CO{sub 2} emissions on a 550 ppm stabilization track. The focus of the paper will be on Carbon Capture and Storage (CCS) as an indispensable part of a carbon constrained energy infrastructure. In CCS our main long term focus is clearly on coal based processes. For Greenfield applications Siemens is prioritizing IGCC based pre-combustion capture. Post-combustion capture is pursued for steam power plant retrofit. (a) IGCC with pre-combustion capture: A first F-class based demonstration plant could be available until 2014. The roadmap addresses gasifier scale up, hydrogen burner and turbine development and integration issues. Beyond that a bundle of further efficiency improvement measures will further enhance efficiency and economic competitiveness. (b) Post-combustion capture: The development aims at optimizing existing solvents or developing new ones and integrating the complete unit with its mass and heat interchange system into the power plant. (c) CO{sub 2} Compressors: For efficiency and operating flexibility reasons Siemens Power Generation prefers gear-type compressors instead of single shaft compressors. The improvement of maintainability and the reduced number of stages or corrosion protection are issues addressed in current R and D activities. (auth)

  19. Leakage of the Siemens 160 MLC multileaf collimator on a dual energy linear accelerator

    International Nuclear Information System (INIS)

    Klueter, Sebastian; Sroka-Perez, Gabriele; Schubert, Kai; Debus, Juergen

    2011-01-01

    Multileaf collimators (MLCs) have been in clinical use for many years and meanwhile are commonly used to deliver intensity-modulated radiotherapy (IMRT) beams. For this purpose it is important to know their dosimetric properties precisely, one of them being inter- and intraleaf leakage. The Siemens 160 MLC features a single focus design with flat-sided and tilted leaves instead of tongue-and-groove. The leakage performance of the 160 MLC was investigated on a dual energy linear accelerator Siemens ARTISTE with 6 MV and 18 MV photon energies. While the intraleaf leakage amounted to nearly the same dose for 6 and for 18 MV, a much higher interleaf leakage for 6 MV was measured. It could be reduced by simply rotating the collimator, and also by changing the voltage applied to the beam steering coils. The leakage of the 160 MLC is shown to be sensitive to beam alignment. This is of special interest for dual energy accelerators, as the two focal spots of both energies, neither in position nor in shape, do not necessarily always coincide. As a consequence of that, a higher leakage can be expected for one out of two energies for the 160 MLC. (note)

  20. Study and evaluation of the Siemens virtual wedge factor: dosimetric monitor system and variable field effects

    Energy Technology Data Exchange (ETDEWEB)

    Sendon Rio, J R Sendon; Martinez, C Otero; GarcIa, M Sanchez; Busto, R Lobato; Vega, V Luna; Sueiro, J Mosquera; Camean, M Pombar [Servizo de Radiofisica e Proteccion Radioloxica, Complexo Hospitalario Universitario de Santiago de Compostela (CHUS), Santiago de Compostela (Spain)], E-mail: jose.ramon.sendon.del.rio@sergas.es

    2008-03-07

    In the year 1997 Siemens introduced the virtual wedge in its accelerators. The idea was that a dose profile similar to that of a physical wedge can be obtained by moving one of the accelerator jaws at a constant speed while the dose rate is changing. This work explores the observed behaviour of virtual wedge factors. A model is suggested which takes into account that at any point in time, when the jaw moves, the dose at a point of interest in the phantom is not only due to the direct beam. It also depends on the scattered radiation in the phantom, the head scatter and the behaviour of the monitoring system of the accelerator. Measurements are performed in a Siemens Primus accelerator and compared to the model predictions. It is shown that the model agrees reasonably well with measurements spanning a wide range of conditions. A strong dependence of virtual wedge factors on the dosimetric board has been confirmed and an explanation has been given on how the balance between different contributions is responsible for virtual wedge factors values.

  1. F-FDG PET/CT (PET/CT) influences management in patients with known or suspected pancreatic cancer

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Kalff, Victor; Cherk, Martin H.; Yap, Kenneth SK.; Evans, Peter; Kelly, Michael J.

    2009-01-01

    Full text: Objective: To assess the impact on clinical management of PET/CT in patients with known or suspected pancreatic cancer. Methods: Between April 2006 and September 2008,25 PET/CT scans were performed using a dedicated PET/CT (22 scans) or a coincidence hybrid PET/CT camera (3 scans) in 23 patients with known or suspected pancreatic cancer. 17 scans were performed for initial evaluation and 8 for restaging of disease. The pre-PET/CT management plan and for intent were prospectively recorded in all cases. The post-PET/CT management plan was determined from the medical record and for discussions with treating clinicians. The impact of PET/CT on management was classified as High, Medium, Low or None, defined using ANZAPNM PET data collection project criteria. Follow-up was used to reconcile any discordance between PET/CT and conventional imaging. Results: Overall, PET/CT management impact was classified as high (n equal 7), medium (n equal 4), low (n equal 10) or none (n equal 4). Impact was either high or medium in l l/25 patients (44%) (95% confidence interval; 24 - 64%). Impact was high in 4/17 patients imaged for initial evaluation, predominantly by clarifying equivocal lesions on conventional imaging. In restaged patients, PET/CT impact was high in 3/8, and it correctly modified disease extent in 5/8. In the 16 discordant studies, PET/CT assessment was correct in 10, conventional imaging in 4 and there was insufficient information in 2. Conclusion: PET/CT has high or medium management impact in 44% of patients imaged for known or suspected pancreatic cancer, more commonly during restaging. Discordant PET/CT results were usually correct.

  2. SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Y; Bowsher, J; Yan, S; Cai, J; Das, S; Yin, F [Duke University Medical Center, Durham, NC (United States)

    2014-06-01

    Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with {sup 18}F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medical Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy.

  3. SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

    International Nuclear Information System (INIS)

    Cui, Y; Bowsher, J; Yan, S; Cai, J; Das, S; Yin, F

    2014-01-01

    Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with 18 F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medical Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy

  4. Pet Problems at Home: Pet Problems in the Community.

    Science.gov (United States)

    Soltow, Willow

    1984-01-01

    Discusses problems of pets in the community, examining the community's role related to disruptive pets and pet overpopulation. Also discusses pet problems at home, offering advice on selecting a pet, meeting a pet's needs, and disciplining pets. Includes a list of books, films/filmstrips, teaching materials, and various instructional strategies.…

  5. MR-guided PET motion correction in LOR space using generic projection data for image reconstruction with PRESTO

    International Nuclear Information System (INIS)

    Scheins, J.; Ullisch, M.; Tellmann, L.; Weirich, C.; Rota Kops, E.; Herzog, H.; Shah, N.J.

    2013-01-01

    The BrainPET scanner from Siemens, designed as hybrid MR/PET system for simultaneous acquisition of both modalities, provides high-resolution PET images with an optimum resolution of 3 mm. However, significant head motion often compromises the achievable image quality, e.g. in neuroreceptor studies of human brain. This limitation can be omitted when tracking the head motion and accurately correcting measured Lines-of-Response (LORs). For this purpose, we present a novel method, which advantageously combines MR-guided motion tracking with the capabilities of the reconstruction software PRESTO (PET Reconstruction Software Toolkit) to convert motion-corrected LORs into highly accurate generic projection data. In this way, the high-resolution PET images achievable with PRESTO can also be obtained in presence of severe head motion

  6. Simultaneous evaluation of brain tumour metabolism, structure and blood volume using [18F]-fluoroethyltyrosine (FET) PET/MRI

    DEFF Research Database (Denmark)

    Henriksen, Otto M.; Larsen, Vibeke A; Muhic, Aida

    2016-01-01

    PURPOSE: Both [(18)F]-fluoroethyltyrosine (FET) PET and blood volume (BV) MRI supplement routine T1-weighted contrast-enhanced MRI in gliomas, but whether the two modalities provide identical or complementary information is unresolved. The aims of the study were to investigate the feasibility...... of simultaneous structural MRI, BV MRI and FET PET of gliomas using an integrated PET/MRI scanner and to assess the spatial and quantitative agreement in tumour imaging between BV MRI and FET PET. METHODS: A total of 32 glioma patients underwent a 20-min static simultaneous PET/MRI acquisition on a Siemens m......MR system 20 min after injection of 200 MBq FET. The MRI protocol included standard structural MRI and dynamic susceptibility contrast (DSC) imaging for BV measurements. Maximal relative tumour FET uptake (TBRmax) and BV (rBVmax), and Dice coefficients were calculated to assess the quantitative and spatial...

  7. PET attenuation correction for rigid MR Tx/Rx coils from 176Lu background activity

    Science.gov (United States)

    Lerche, Christoph W.; Kaltsas, Theodoris; Caldeira, Liliana; Scheins, Jürgen; Rota Kops, Elena; Tellmann, Lutz; Pietrzyk, Uwe; Herzog, Hans; Shah, N. Jon

    2018-02-01

    One challenge for PET-MR hybrid imaging is the correction for attenuation of the 511 keV annihilation radiation by the required RF transmit and/or RF receive coils. Although there are strategies for building PET transparent Tx/Rx coils, such optimised coils still cause significant attenuation of the annihilation radiation leading to artefacts and biases in the reconstructed activity concentrations. We present a straightforward method to measure the attenuation of Tx/Rx coils in simultaneous MR-PET imaging based on the natural 176Lu background contained in the scintillator of the PET detector without the requirement of an external CT scanner or PET scanner with transmission source. The method was evaluated on a prototype 3T MR-BrainPET produced by Siemens Healthcare GmbH, both with phantom studies and with true emission images from patient/volunteer examinations. Furthermore, the count rate stability of the PET scanner and the x-ray properties of the Tx/Rx head coil were investigated. Even without energy extrapolation from the two dominant γ energies of 176Lu to 511 keV, the presented method for attenuation correction, based on the measurement of 176Lu background attenuation, shows slightly better performance than the coil attenuation correction currently used. The coil attenuation correction currently used is based on an external transmission scan with rotating 68Ge sources acquired on a Siemens ECAT HR  +  PET scanner. However, the main advantage of the presented approach is its straightforwardness and ready availability without the need for additional accessories.

  8. Technology challenges in small animal PET imaging

    International Nuclear Information System (INIS)

    Lecomte, Roger

    2004-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging modality allowing biochemical processes to be investigated in vivo with sensitivity in the picomolar range. For this reason, PET has the potential to play a major role in the emerging field of molecular imaging by enabling the study of molecular pathways and genetic processes in living animals non-invasively. The challenge is to obtain a spatial resolution that is appropriate for rat and mouse imaging, the preferred animal models for research in biology, while achieving a sensitivity adequate for real-time measurement of rapid dynamic processes in vivo without violating tracer kinetic principles. An overview of the current state of development of dedicated small animal PET scanners is given, and selected applications are reported and discussed with respect to performance and significance to research in biology

  9. A Very High Spatial Resolution Detector for Small Animal PET

    International Nuclear Information System (INIS)

    Kanai Shah, M.S.

    2007-01-01

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated

  10. Brain PET scan

    Science.gov (United States)

    ... results on a PET scan. Blood sugar or insulin levels may affect the test results in people with diabetes . PET scans may be done along with a CT scan. This combination scan is called a PET/CT. Alternative Names Brain positron emission tomography; PET scan - brain References Chernecky ...

  11. The power control system of the Siemens-KWU nuclear power station of the PWR [pressurized water reactors] type

    International Nuclear Information System (INIS)

    Huber, Horacio

    1989-01-01

    Starting with the first nuclear power plant constructed by Siemens AG of the pressurized light water reactor line (PWR), the Obrigheim Nuclear Power Plant (340 MWe net), until the recently constructed plants of 1300 MWe (named 'Konvoi'), the design of the power control system of the plant was continuously improved and optimized using the experience gained in the operation of the earlier generations of plants. The reactor power control system of the Siemens - KWU nuclear power plants is described. The features of this design and of the Siemens designed heavy water power plants (PHWR) Atucha I and Atucha II are mentioned. Curves showing the behaviour of the controlled variables during load changes obtained from plant tests are also shown. (Author) [es

  12. Direct comparison of 18F-FDG and 11C-methionine PET in suspected recurrence of glioma: sensitivity, inter-observer variability and prognostic value

    International Nuclear Information System (INIS)

    Laere, Koen Van; Ceyssens, Sarah; Mortelmans, Luc; Calenbergh, Frank Van; Groot, Tjibbe de; Bormans, Guy; Menten, Johan; Flamen, Patrick

    2005-01-01

    18 F-fluorodeoxyglucose (FDG) and 11 C-methionine (MET) PET imaging studies allow the investigation of metabolism and amino acid transport in brain tumours. Their (relative) usefulness and prognostic value in suspected recurrence or progression of primary brain tumours after previous therapy is an issue of debate. The aim of this study was to compare directly both radioligands in this setting. Cerebral uptake of FDG and MET was determined sequentially on the same day in 30 patients (21 males, nine females; age 40.4±15.6 years), on average 4.0 years (range 0.1-18) after therapy for a primary brain tumour (23 grade II-IV astrocytomas, four oligodendrogliomas and three mixed oligo-astrocytomas). Images were acquired on a Siemens HR+ dedicated PET camera. Two observers scored FDG and MET scans independently. Semi-quantitative indices defined by the tumour (maximum)-to-background ratio were calculated based on manual ROI delineation and by using MET ROIs for FDG after automated co-registration. Patient follow-up was conducted until the last contact with inconspicuous clinical findings (average 41 months, range 12-62 months after PET) [(n=10)] or until death (n=20). Overall median survival was 15.0 months. MET showed pathologically increased uptake in 28/30 scans, and FDG in 17/30. The inter-observer agreement was 100% for MET and 73% for FDG. Using Kaplan-Meier survival analysis, significant differences were found for both FDG (cut-off 0.8, log-rank p=0.007) and MET (cut-off 2.2, log-rank p=0.014). The combination of FDG and MET information resulted in the highest prognostic accuracy (p=0.003), while MET alone was the best prognostic predictor in the subgroup of patients with primary astrocytoma (n=23). FDG and MET PET studies provide complementary prognostic information in patients with suspected brain tumour recurrence or progression after primary therapy. MET is considered the single agent of choice in the evaluation of these patients because of its sensitivity and

  13. Direct comparison of {sup 18}F-FDG and {sup 11}C-methionine PET in suspected recurrence of glioma: sensitivity, inter-observer variability and prognostic value

    Energy Technology Data Exchange (ETDEWEB)

    Laere, Koen Van; Ceyssens, Sarah; Mortelmans, Luc [University Hospital Leuven, Division of Nuclear Medicine, Leuven (Belgium); Calenbergh, Frank Van [University Hospital Leuven, Department of Neurosurgery, Leuven (Belgium); Groot, Tjibbe de; Bormans, Guy [University Hospital Leuven, Laboratory of Radiopharmaceutical Chemistry, Leuven (Belgium); Menten, Johan [University Hospital Leuven, Division of Radiotherapy, Leuven (Belgium); Flamen, Patrick [University Hospital Leuven, Division of Nuclear Medicine, Leuven (Belgium); Bordet Hospital, Division of Nuclear Medicine, Brussels (Belgium)

    2005-01-01

    {sup 18}F-fluorodeoxyglucose (FDG) and {sup 11}C-methionine (MET) PET imaging studies allow the investigation of metabolism and amino acid transport in brain tumours. Their (relative) usefulness and prognostic value in suspected recurrence or progression of primary brain tumours after previous therapy is an issue of debate. The aim of this study was to compare directly both radioligands in this setting. Cerebral uptake of FDG and MET was determined sequentially on the same day in 30 patients (21 males, nine females; age 40.4{+-}15.6 years), on average 4.0 years (range 0.1-18) after therapy for a primary brain tumour (23 grade II-IV astrocytomas, four oligodendrogliomas and three mixed oligo-astrocytomas). Images were acquired on a Siemens HR+ dedicated PET camera. Two observers scored FDG and MET scans independently. Semi-quantitative indices defined by the tumour (maximum)-to-background ratio were calculated based on manual ROI delineation and by using MET ROIs for FDG after automated co-registration. Patient follow-up was conducted until the last contact with inconspicuous clinical findings (average 41 months, range 12-62 months after PET) [(n=10)] or until death (n=20). Overall median survival was 15.0 months. MET showed pathologically increased uptake in 28/30 scans, and FDG in 17/30. The inter-observer agreement was 100% for MET and 73% for FDG. Using Kaplan-Meier survival analysis, significant differences were found for both FDG (cut-off 0.8, log-rank p=0.007) and MET (cut-off 2.2, log-rank p=0.014). The combination of FDG and MET information resulted in the highest prognostic accuracy (p=0.003), while MET alone was the best prognostic predictor in the subgroup of patients with primary astrocytoma (n=23). FDG and MET PET studies provide complementary prognostic information in patients with suspected brain tumour recurrence or progression after primary therapy. MET is considered the single agent of choice in the evaluation of these patients because of its

  14. Development of system design in recent Siemens/KWU PWR influenced by PSA results

    International Nuclear Information System (INIS)

    Feigel, A.; Fabian, H.

    1989-01-01

    This paper reports on the design of the latest Siemens/KWU PWRs (Convoy plants) which is checked by a PSA, performed as a Δ-analysis to the German Risk Study (GPRA), which used a PWR 1300 MW in commercial operation since 1977 as a reference plant. The 10 years difference in the design between the reference plant and the Convoy plants, led to design changes, due to operational experience and findings from GPRA, Phase A. These are evaluated quantitatively by a PSA with respect to plat safety level and balance of the safety concept. The results gained from the Convoy PSA showed the importance and appropriateness of these modifications. Even if the latest results from GPRA, Phase B are considered with respect to additional accident sequences, it can be demonstrated that the new design is balanced with respect to these additional sequences. So no need exists to improve the new design any more

  15. Siemens solar CIS photovoltaic module and system performance at the National Renewable Energy Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Strand, T.; Kroposki, B.; Hansen, R. [National Renewable Energy Lab., Golden, CO (United States); Willett, D. [Siemens Solar Industries, Camarillo, CA (United States)

    1996-05-01

    This paper evaluates the individual module and array performance of Siemens Solar Industries copper indium diselenide (CIS) polycrystalline thin-film technology. This is accomplished by studying module and array performance over time. Preliminary temperature coefficients for maximum power, maximum-power voltage, maximum-power current, open-circuit voltage, short-circuit current, and fill factor are determined at both the module and array level. These coefficients are used to correct module/array performance to 25{degrees}C to evaluate stability. The authors show that CIS exhibits a strong inverse correlation between array power and back-of-module temperature. This is due mainly to the narrow bandgap of the CIS material, which results in a strong inverse correlation between voltage and temperature. They also show that the temperature-corrected module and array performance has been relatively stable over the evaluation interval ({approx}2 years).

  16. Siemens Nuclear Power Corporation methods development for BWR/PWR reactor licensing

    International Nuclear Information System (INIS)

    Pruitt, D.W.

    1992-01-01

    This presentation addresses the Siemens Nuclear Power Corporation (SNP) perspective on the primary forces driving methods development in the nuclear industry. These forces are fuel design, computational environment and industry requirement evolution. The first segment of the discussion presents the SNP experience base. SNP develops, manufactures and licenses both BWR and PWR reload fuel. A review of this experience base highlights the accelerating rate at which new fuel designs are being introduced into the nuclear industry. The application of advanced BWR lattice geometries provides an example of fuel design trends. The second aspect of the presentation is the rapid evolution of the computing environment. The final subject in the presentation is the impact of industry requirements on code or methods development

  17. Accurate Modeling of The Siemens S7 SCADA Protocol For Intrusion Detection And Digital Forensic

    Directory of Open Access Journals (Sweden)

    Amit Kleinmann

    2014-09-01

    Full Text Available The Siemens S7 protocol is commonly used in SCADA systems for communications between a Human Machine Interface (HMI and the Programmable Logic Controllers (PLCs. This paper presents a model-based Intrusion Detection Systems (IDS designed for S7 networks. The approach is based on the key observation that S7 traffic to and from a specific PLC is highly periodic; as a result, each HMI-PLC channel can be modeled using its own unique Deterministic Finite Automaton (DFA. The resulting DFA-based IDS is very sensitive and is able to flag anomalies such as a message appearing out of its position in the normal sequence or a message referring to a single unexpected bit. The intrusion detection approach was evaluated on traffic from two production systems. Despite its high sensitivity, the system had a very low false positive rate - over 99.82% of the traffic was identified as normal.

  18. Siemens experience on linear and nonlinear analyses of out-of-phase BWR instabilities

    International Nuclear Information System (INIS)

    Kreuter, D.; Wehle, F.

    1995-01-01

    The Siemens design code STAIF has been applied extensively for linear analysis of BWR instabilities. The comparison between measurements and STAIF calculations for different plants under various conditions has shown good agreement for core-wide and regional instabilities. Based on the high quality of STAIF, the North German TUeV has decided to replace the licensing requirement of extensive stability measurements by predictive analyses with the code STAIF. Nonlinear stability analysis for beyond design boundary conditions with RAMONA has shown dryout during temporarily reversed flow at core inlet in case of core-wide oscillations. For large out-of-phase oscillations, dryout occurs already for small, still positive channel inlet flow. (orig.)

  19. Advanced PWR Core Design with Siemens High-Plutonium-Content MOX Fuel Assemblies

    International Nuclear Information System (INIS)

    Dieter Porsch; Gerhard Schlosser; Hans-Dieter Berger

    2000-01-01

    The Siemens experience with plutonium recycling dates back to the late 1960s. Over the years, extensive research and development programs were performed for the qualification of mixed-oxide (MOX) technology and design methods. Today's typical reload enrichments for uranium and MOX fuel assemblies and modern core designs have become more demanding with respect to accuracy and reliability of design codes. This paper presents the status of plutonium recycling in operating high-burnup pressurized water reactor (PWR) cores. Based on actual examples, it describes the validation status of the design methods and stresses current and future needs for fuel assembly and core design including those related to the disposition of weapons-grade plutonium

  20. Ghosting effect in Siemens electronic portal imaging devices (EPIDs) for step and shoot IMRT dosimetry

    International Nuclear Information System (INIS)

    Deshpande, S.; Vial, P.; Goozee, G.; Holloway, L.

    2010-01-01

    Full text: To assess the ghosting effect of a Siemens EPID (Optivue 1000: while acquiring IMRT fluence with step and shoot delivery. Six sets of segmented fields with 1,2,3,5, J( and 20 monitor units (MU) per segment were designed. Each set consisted of ten segments of equal MU and field size (J 0 x 10 cm 2 ) Standard single fields (non-segmented) of the same total MU as the segmented fields were also created (10-200 MU). EPID images for these fields were acquired with multi-frame acquisition mode. The integrated EPID response was determined as the mean central 20 x 21 pixel readout multiplied by the number of frames. The same fields wen measured with an ionization chamber at a depth of dose maximum in, solid water phantom. The total signal measured from the segmented fields was compared to the corresponding non-segmented fields. The ratio of EPID response between segmented and non-segmented delivery indicates an under-response for segmented fields by 5, 4, 2.5 and 2% for 1,2,3, and 5 MU per segment exposures respectively compared to ionisation chamber response (se Fig. I). The ratio was within 2% for 5 MU per segment and above. Th error bar in Fig. I indicate the intra-segment response variation. The Siemens EPID exhibited significant ghosting effect and variation in response for small M U segments. EPID dosimetry ( IMRT fields with less than 5 MU per segment requires corrections t maintain dose calibration accuracy to within 2%. (author)

  1. Overview, practical tips and potential pitfalls of using automatic exposure control in CT: Siemens care dose 4D

    International Nuclear Information System (INIS)

    Soederberg, Marcus

    2016-01-01

    Today, computed tomography (CT) systems routinely use automatic exposure control (AEC), which modulates the tube current. However, for optimal use, there are several aspects of an AEC system that need to be considered. The purpose of this study was to provide an overview of the Siemens CARE Dose 4D AEC system, discuss practical tips and demonstrate potential pitfalls. Two adult anthropomorphic phantoms were examined using two different Siemens CT systems. When optimising the CT radiation dose and image quality, the projection angle of the localiser, patient centring, protocol selection, scanning direction and the use of protective devices requires special attention. (authors)

  2. Analisis Studi Komperatif Perbandingan Key Performance Index Swap Huawei dengan Nokia Siemens Network pada Operator Telkomsel (Sto Tebas)

    OpenAIRE

    Jimmy

    2015-01-01

    – The need for telecommunications is very important and makes the mobile operators including Telkomsel are trying ways to improvise their network system, by optimizing the BTSs one of way is to maintain and even increase the success call rate by optimizing the device by swapping Huawei BTS to Nokia Siemens Network (NSN) BTS. The results of the KPI comparison between the Huawei's BTS with Nokia Siemens Network's on the SDSR on Huawei BTS percentage of success rate is 99.59% raised calls is hig...

  3. An Austrian framework for PET quality control

    International Nuclear Information System (INIS)

    Nicoletti, R.; Dobrozemsky, G.; Minear, G.; Bergmann, H.

    2002-01-01

    Full text: The European patient protection directive (97/43 EURATOM) requires regular routine quality control (QC) of PET imaging devices. Since no standards were available covering this area and in order to comply with the directive a joint working party of the Austrian societies of nuclear medicine and of medical physics have developed a set of procedures suitable for both dedicated PET scanners and gamma cameras operating in coincidence mode (GCPET). The routine procedures proposed include both manufacturer recommended procedures and tests for specific parameters and calibration procedures. Wherever possible, procedures adapted or derived from NEMA standards publication NU 2-2001 were used to permit direct comparison with specified parameters of image quality. For dedicated PET scanners the most important procedures are the checking of detector sensitivities and the attenuation calibration scan. With full ring scanners the attenuation calibration scan is a blank scan, with partial ring devices a special attenuation calibration phantom has to be used. Test protocols are specific to manufacturer and scanner type. They are usually performed automatically overnight. In addition, some instruments require special calibrations, e.g. gain adjustments or coincidence timing calibration. GCPET procedures include the frequent assessment in coincidence mode of detector uniformity, energy resolution and system sensitivity. Common to both dedicated PET and GCPET are the regular quarterly assessment of tomographic spatial resolution and the calibration of the system for quantitative measurements. As a total performance test for both systems assessment of image quality following NU 2-2001 was included, to be carried out after major system changes or repairs. The suite of QC procedures was tested on several dedicated PET and GCPET systems including all major manufacturers' systems. Due to missing hardware or software not all tests could be performed on all systems. Some of the

  4. PET reconstruction

    International Nuclear Information System (INIS)

    O'Sullivan, F.; Pawitan, Y.; Harrison, R.L.; Lewellen, T.K.

    1990-01-01

    In statistical terms, filtered backprojection can be viewed as smoothed Least Squares (LS). In this paper, the authors report on improvement in LS resolution by: incorporating locally adaptive smoothers, imposing positivity and using statistical methods for optimal selection of the resolution parameter. The resulting algorithm has high computational efficiency relative to more elaborate Maximum Likelihood (ML) type techniques (i.e. EM with sieves). Practical aspects of the procedure are discussed in the context of PET and illustrations with computer simulated and real tomograph data are presented. The relative recovery coefficients for a 9mm sphere in a computer simulated hot-spot phantom range from .3 to .6 when the number of counts ranges from 10,000 to 640,000 respectively. The authors will also present results illustrating the relative efficacy of ML and LS reconstruction techniques

  5. Imaging and PET - PET/CT imaging

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Hany, Th.F.

    2008-01-01

    PET/CT has grown because the lack of anatomic landmarks in PET makes 'hardware-fusion' to anatomic cross-sectional data extremely useful. Addition of CT to PET improves specificity, but also sensitivity, and adding PET to CT adds sensitivity and specificity in tumor imaging. The synergistic advantage of adding CT is that the attenuation correction needed for PET data can also be derived from the CT data. This makes PET-CT 25-30% faster than PET alone, leading to higher patient throughput and a more comfortable examination for patients typically lasting 20 minutes or less. FDG-PET-CT appears to provide relevant information in the staging and therapy monitoring of many tumors, such as lung carcinoma, colorectal cancer, lymphoma, gynaecological cancers, melanoma and many others, with the notable exception of prostatic cancer. for this cancer, choline derivatives may possibly become useful radiopharmaceuticals. The published literature on the applications of FDG-PET-CT in oncology is still limited but several designed studies have demonstrated the benefits of PET-CT. (authors)

  6. VARIABILITY OF FORCED OSCILLATION (SIEMENS SIREGNOST FD-5) MEASUREMENTS OF TOTAL RESPIRATORY RESISTANCE IN PATIENTS AND HEALTHY-SUBJECTS

    NARCIS (Netherlands)

    GIMENO, F; VANDERWEELE, LT; KOETER, GH; DEMONCHY, JGR; VANALTENA, R

    The reproducibility of total respiratory resistance (R(rs)) measured with a simplified forced oscillatory method (Siemens Siregnost FD 5) was measured and compared with that of slow inspiratory vital capacity (IVC) and forced expiratory volume in one second (FEV1). The former technique has the

  7. En undersøgelse af de 253 første nyrestensbehandlinger med 3. generations Siemens Lithoskop™

    DEFF Research Database (Denmark)

    Kruckow, Line; Eldrup, Jesper

    Introduktion: Kandidatspecialets formål er at undersøge et års behandlinger af nyresten ved ny stenknuser, Siemens Lithoskop. Undersøgelsen fokuserer på hvorvidt stenstørrelse, BMI og stenplacering har indflydelse på stenfrihedsraten. Metode: Mellem 6/12-11 og 11/12-12 blev 253 behandlinger og...

  8. Multimodal imaging: Simultaneous EEG in a 3T Hybrid MR–PET system

    Energy Technology Data Exchange (ETDEWEB)

    Neuner, I., E-mail: i.neuner@fz-juelich.de [Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH (Germany); Department of Psychiatry, Psychotherapy and Psychosomatics, RWTH Aachen University (Germany); JARA BRAIN—Translational Medicine (Germany); Warbrick, T.; Tellmann, L.; Rota Kops, E.; Arrubla, J.; Boers, F.; Herzog, H. [Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH (Germany); Shah, N.J. [Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH (Germany); Department of Neurology, RWTH Aachen University (Germany); JARA BRAIN—Translational Medicine (Germany)

    2013-02-21

    The new generation of integrated MR–PET systems allows the simultaneous acquisition of MR and PET data. While MR delivers structural data with an excellent spatial resolution, the advantage of PET is its information on a molecular level. However, both modalities have a low temporal resolution. Thus, for pharmacological studies or patients who suffer from treatment resistant epilepsy the combination of yet another modality such as EEG could be desirable. We tested the feasibility of evoked visual potentials in a 3T Hybrid MR–PET system (Siemens Germany) in comparison to a standalone 3T Trio System (Siemens Germany). A T2⁎-weighted EPI sequence was used: TR: 2.2 s, TE: 30 ms, FOV: 200 mm, slice thickness 3, 36 slices in a healthy volunteer (male, 27 years old) using an MR-compatible 32-channel EEG system (Brainproducts, Munich, Germany). We applied 200 trials of visual stimulation from a white and black checkerboard. Visual evoked potentials were analyzed using Brain Vision Analyzer (Brainproducts, Munich, Germany). Gradient correction and cardioballistic artefact correction were performed as implemented in Vision Analyzer. Visual event related potentials were successfully recorded at the 3T Hybrid MR–PET system. Both curves differ slightly in shape and latency due to the following factors: the distance from the screen varies slightly and the size of the field of view of the subjects is smaller in the 3T MR–PET system in comparison to the 3T stand alone system. Extending the 3T MR–PET Hybrid system to 3T Hybrid MR–PET–EEG is feasible and adds another tool to clinical neuroimaging and research.

  9. Trends in PET imaging

    International Nuclear Information System (INIS)

    Moses, William W.

    2000-01-01

    Positron Emission Tomography (PET) imaging is a well established method for obtaining information on the status of certain organs within the human body or in animals. This paper presents an overview of recent trends PET instrumentation. Significant effort is being expended to develop new PET detector modules, especially those capable of measuring depth of interaction. This is aided by recent advances in scintillator and pixellated photodetector technology. The other significant area of effort is development of special purpose PET cameras (such as for imaging breast cancer or small animals) or cameras that have the ability to image in more than one modality (such as PET / SPECT or PET / X-Ray CT)

  10. 6 MV dosimetric characterization of the 160 MLC, the new Siemens multileaf collimator

    International Nuclear Information System (INIS)

    Tacke, Martin B.; Nill, Simeon; Haering, Peter; Oelfke, Uwe

    2008-01-01

    New technical developments constantly aim at improving the outcome of radiation therapy. With the use of a computer-controlled multileaf collimator (MLC), the quality of the treatment and the efficiency in patient throughput is significantly increased. New MLC designs aim to further enhance the advantages. In this article, we present the first detailed experimental investigation of the new 160 MLC TM , Siemens Medical Solutions. The assessment included the experimental investigation of typical MLC characteristics such as leakage, tongue-and-groove effect, penumbra, leaf speed, and leaf positioning accuracy with a 6 MV treatment beam. The leakage is remarkably low with an average of 0.37% due to a new design principle of slightly tilted leaves instead of the common tongue-and-groove design. But due to the tilt, the triangular tongue-and-groove effect occurs. Its magnitude of approximately 19% is similar to the dose defect measured for MLCs with the common tongue-and-groove design. The average longitudinal penumbra measured at depth d max =15 mm with standard 100x100 mm 2 fields is 4.1±0.5 mm for the central range and increases to 4.9±1.3 mm for the entire field range of 400x400 mm 2 . The increase is partly due to the single-focusing design and the large distance between the MLC and the isocenter enabling a large patient clearance. Regarding the leaf speed, different velocity tests were performed. The positions of the moving leaves were continuously recorded with the kilovoltage-imaging panel. The maximum leaf velocities measured were 42.9±0.6 mm/s. In addition, several typical intensity-modulated radiation therapy treatments were performed and the delivery times compared to the Siemens OPTIFOCUS MLC. An average decrease of 11% in delivery time was observed. The experimental results presented in this article indicate that the dosimetric characteristics of the 160 MLC are capable of improving the quality of dose delivery with respect to precision and dose

  11. PET / MRI vs. PET / CT. Indications Oncology

    International Nuclear Information System (INIS)

    Oliva González, Juan P.

    2016-01-01

    Hybrid techniques in Nuclear Medicine is currently a field in full development for diagnosis and treatment of various medical conditions. With the recent advent of PET / MRI much it speculated about whether or not it is superior to PET / CT especially in oncology. The Conference seeks to clarify this situation by dealing issues such as: State of the art technology PET / MRI; Indications Oncology; Some clinical cases. It concludes by explaining the oncological indications of both the real and current situation of the PET / MRI. (author)

  12. FDG PET/CT findings in a clinically diagnosed case of childhood autism

    International Nuclear Information System (INIS)

    Manglunia, Ashmi S.; Puranik, Ameya D.

    2016-01-01

    Autism is a neurodevelopmental disorder with multifactorial etiology and varied presentation, in which early diagnosis is crucial to the implementation of early treatment. A 6-year-old child clinically diagnosed with autism, and a normal magnetic resonance imaging underwent dedicated 18F-fluorodeoxyglucose brain positron emission tomography (PET) as an ancillary investigation. PET image showed diffuse bilateral temporal hypometabolism. Although PET imaging is currently not indicated in the evaluation of autism, characteristic imaging patterns on PET can provide corroborative information and increase the diagnostic confidence for the same

  13. DARE: a dedicated aerosols retrieval instrument

    NARCIS (Netherlands)

    Court, A.J.; Smorenburg, K.; Courrèges-Lacoste, G.B.; Visser, H.; Leeuw, G. de; Decae, R.

    2004-01-01

    Satellite remote sensing of aerosols is a largely unresolved problem. A dedicated instrument aimed at aerosols would be able to reduce the large uncertainties connected to this kind of remote sensing. TNO is performing a study of a space based instrument for aerosol measurements, together with the

  14. FDG-PET identification of intraperitoneal metastases

    International Nuclear Information System (INIS)

    Gamez, C.; Jimenez-Hoyuelam, J.M.; Rebollo, A.C.; Gonzalez, P.; Rico, J.M.; Alba, E.; Sacchetti, A.; Lopez-Rueda, B.

    2002-01-01

    Aim: Peritoneal metastases (PM) are usually from intra-abdominal primary neoplasms, such as carcinoma of the stomach, colon, ovary, and pancreas, or from intra-abdominal lymphoma. Metastases disseminate throughout the peritoneum in four ways: 1) direct spread along peritoneal ligaments, mesenteries and omenta; 2) via the flow of ascitis fluid. 3) lymphatic extension, and 4) embolic hematogenous spread. Although CT is quite specific in identifying PM it is not very sensitive, and peritoneal lavage or biopsy can be very useful but have sampling errors. This study assessed the clinical value of FDG-PET for the detection of PM of malignant diseases. Materials and Methods: 15 FDG-PET scans of patients referred for recurrence (mean age = 54 y/o, sex = 6M, 9F), with metabolic abnormalities suspicious findings of PM from carcinoma of the colon (7), ovary (3), lymphoma (2), pancreas (1), gastrointestinal stromal tumor (1) and melanoma (1) were reviewed. The whole-body studies were performed 50 min following the intravenous administration of 370 MBq of 18F-FDG, in a high resolution dedicated PET scanner (Advance, GEMS), with images reconstructed using a iterative algorithm with segmented attenuation correction. Visual interpretation and SUV values were correlated with CT/MRI findings and biopsy/follow-up. Results: Of the 15 patients, 7 showed <3 sites of focal uptake and 8 presented multiple foci or a diffuse hypermetabolism in the abdomen (SUVmax3.04-18.83 g/ml). 6 patients had biopsy confirmation by PET-directed surgery (6 proven PM, 0 negative biopsies). 11 FDG-PET scans had correspondence with the CT/MRI findings and 4 showed discrepancies (PET positive-CT/MRI negative in patients with isolated raising tumor markers levels or unsuspected PM). FDG-PET influenced the therapeutic management in 2 patients as presented multiple metastases leading them from surgery to chemotherapy. Conclusion: When used as a complementary imaging tool to the conventional work up, FDG-PET is

  15. Pets and Parasites

    Science.gov (United States)

    ... good news is that this rarely happens. Most pet-to-people diseases can be avoided by following a few ... your doctor Can a parasite cause death in people and pets? Can human disease from a parasite be treated ...

  16. Heart PET scan

    Science.gov (United States)

    ... nuclear medicine scan; Heart positron emission tomography; Myocardial PET scan ... A PET scan requires a small amount of radioactive material (tracer). This tracer is given through a vein (IV), ...

  17. [Principles of PET].

    Science.gov (United States)

    Beuthien-Baumann, B

    2018-05-01

    Positron emission tomography (PET) is a procedure in nuclear medicine, which is applied predominantly in oncological diagnostics. In the form of modern hybrid machines, such as PET computed tomography (PET/CT) and PET magnetic resonance imaging (PET/MRI) it has found wide acceptance and availability. The PET procedure is more than just another imaging technique, but a functional method with the capability for quantification in addition to the distribution pattern of the radiopharmaceutical, the results of which are used for therapeutic decisions. A profound knowledge of the principles of PET including the correct indications, patient preparation, and possible artifacts is mandatory for the correct interpretation of PET results.

  18. Application of self-assessment in the nuclear fuel supply activities of Siemens AG

    International Nuclear Information System (INIS)

    Nilson, F.; Schaule, B.

    2000-01-01

    The quality of fuel assemblies supplied to our customers is defined by more than just their expected functionality (performance) during reactor operation and beyond but also by their cost (price) and the timeliness of their supply (including related services). This perspective implies a comprehensive view of the quality of business, - the same focus that the IAEA Code, Basic Requirement 9, addresses regarding management self-assessment. Siemens has adopted a comprehensive management philosophy in the Nuclear Fuels Business in the early Nineties under the header of 'TQM' that is similar to the one mentioned above. For this approach we found valuable guidance in the Business Excellence model of the European Foundation for Quality Management (EFQM) which is comparable to the self-assessment criteria listed by IAEA. In this contribution we are presenting examples and experiences of how such system of self-assessment and continuous improvement was implemented by senior management. Our experience of more than 6 years of TQM and 4 years of self-assessment yielded an increasing alignment and focus of our organization and all its members on the continuous improvement of our processes (business, management and support) - on the way to a learning organization. (author)

  19. Acceptance testing of Siemens e.cam SPECT system at the Korle-Bu Teaching Hospital

    International Nuclear Information System (INIS)

    Sosu, K. E.

    2006-01-01

    Acceptance testing has been performed on the Siemens e.cam Signature Series (Single Head) Single Photon Emission Computed Tomography (SPECT) system; the first of its kind, at the Nuclear Medicine Department, Korle-Bu Teaching Hospital, Accra. The various tests were performed according to NEMA NU 1 (2001) specifications as far as possible. The most important parameters that characterized the performance of the camera, gantry system, patient bed, collimators, computer system and fundamental software were evaluated based on visual inspection techniques. Various measuring instruments, different kinds of phantoms, point and flood sources containing 99m-Tc were also used for quantitative studies. Tests performed were divided into Physical inspection, intrinsic measurements (without collimator), extrinsic measurements (with collimator) and Single Photon Emission Computed Tomography (SPECT) system measurement. Some results obtained were better than factory specifications, others were within specifications. Other results obtained from this study which did not have factory specifications for comparison can serve as baseline for future measurements and quality control. Although not all the tests originally planned for could be done due to the non-availability of certain phantoms and radionuclide, it had been possible to perform sufficient and relevant tests to ensure that the system had no serious problems and that it can be used for clinical nuclear medicine imaging. (au)

  20. Comparison of dosimetric characteristics of Siemens virtual and physical wedges for ONCOR linear accelerator

    Directory of Open Access Journals (Sweden)

    Attalla Ehab

    2010-01-01

    Full Text Available Dosimetric properties of virtual wedge (VW and physical wedge (PW in 6- and 10-MV photon beams from a Siemens ONCOR linear accelerator, including wedge factors, depth doses, dose profiles, peripheral doses, are compared. While there is a great difference in absolute values of wedge factors, VW factors (VWFs and PW factors (PWFs have a similar trend as a function of field size. PWFs have stronger depth dependence than VWF due to beam hardening in PW fields. VW dose profiles in the wedge direction, in general, match very well with those of PW, except in the toe area of large wedge angles with large field sizes. Dose profiles in the nonwedge direction show a significant reduction in PW fields due to off-axis beam softening and oblique filtration. PW fields have significantly higher peripheral doses than open and VW fields. VW fields have similar surface doses as the open fields, while PW fields have lower surface doses. Surface doses for both VW and PW increase with field size and slightly with wedge angle. For VW fields with wedge angles 45° and less, the initial gap up to 3 cm is dosimetrically acceptable when compared to dose profiles of PW. VW fields in general use less monitor units than PW fields.

  1. Status of Siemens steam generator design and measures to assure continuous long-term reliable operation

    International Nuclear Information System (INIS)

    Hoch, G.

    1999-01-01

    Operating pressurized water reactors with U-tube steam generators have encountered difficulties with either one or a combination of inadequate material selection, poor design or manufacturing and an insufficient water chemistry control which resulted in excessive tube degradation. In contrast to the above mentioned problems, steam generators from Siemens/KWU are proving by operating experience that all measures undertaken at the design stage as well as during the operating and maintenance phase were effective enough to counteract any tube corrosion phenomena or other steam generator related problem. An Integrated Service Concept has been developed, applied and wherever necessary improved in order to ensure reliable steam generator operation. The performance of the steam generators is updated continuously, evaluated and implemented in lifetime databases. The main indicator for steam generator integrity are the results of the eddy current testing of the steam generator tubes. Tubes with indications are rated with lifetime threshold values and if necessary plugged, based on individual assessment criteria.(author)

  2. PET/CT diagnostic of colo-rectal cancers

    International Nuclear Information System (INIS)

    Straciuc, O.

    2012-01-01

    Full text: Objective: Presenting the advantages of Positron Emission Tomography/Computed Tomography (PET/ CT) examination, using the radiotracer fluorure 18-deoxyglucose (FDG) in colo-rectal cancer diagnostic. Basics of the method will be also presented. Introduction: FDG PET/CT is recognized as the most efficient diagnostic imaging weapon in colorectal cancer, enable too comprehend all the 3 targets needed for staging of colo-rectal cancers: 1)Detection and evaluation of primary tumor (T) and recurrence; 2) Lymphadenopathy (N); 3)Metastatic disease (M). Assessment of treatment response during and after therapy, follow up and radiotherapy planning are also indications for PET/CT. There are two essential advantages of the method: 1)The whole body examination; 2)The complementary morphological information offered by CT and functional information offered by PET. Material and methods: Study of a total of 394 patients diagnosed with colo-rectal cancer of the total of 4125 investigated by PET/CT in Diagnosztika Pozitron center of Oradea, between 01.06.2008 - 06.06.2012. All cases had documented preoperative or postoperative histopathologic evaluation. We used a Siemens Biograph 16 device and only FDG as radiotracer, injected intravenously at a dose of 0.1-0.15 mCi /kg. Standard protocol of examination was performed at 60 minutes after FDG injection. CT acquisition consists of 'low dose' from vertex to thighs, followed by PET acquisition in 7 to 8 beds. Results: We followed the performance of PET/CT diagnostic in staging and restaging of colorectal cancer compared with other imaging methods. 141 patients had negative examinations. 107 patients were diagnosed with locally recurrent lesions, lymphadenopathy and/ or metastases. Compared with the results of previous imaging new metabolically active lesions were detected in 87 patients by PET/CT and suspected lesions were denied in 48 patients. Significant clinically cases are presented. Conclusions: The data obtained by PET

  3. A 16-channel MR coil for simultaneous PET/MR imaging in breast cancer

    International Nuclear Information System (INIS)

    Dregely, Isabel; Lanz, Titus; Mueller, Matthias F.; Metz, Stephan; Kuschan, Marika; Nimbalkar, Manoj; Ziegler, Sibylle I.; Nekolla, Stephan G.; Schwaiger, Markus; Bundschuh, Ralph A.; Haase, Axel

    2015-01-01

    To implement and evaluate a dedicated receiver array coil for simultaneous positron emission tomography/magnetic resonance (PET/MR) imaging in breast cancer. A 16-channel receiver coil design was optimized for simultaneous PET/MR imaging. To assess MR performance, the signal-to-noise ratio, parallel imaging capability and image quality was evaluated in phantoms, volunteers and patients and compared to clinical standard protocols. For PET evaluation, quantitative 18 F-FDG PET images of phantoms and seven patients (14 lesions) were compared to images without the coil. In PET image reconstruction, a CT-based template of the coil was combined with the MR-acquired attenuation correction (AC) map of the phantom/patient. MR image quality was comparable to clinical MR-only examinations. PET evaluation in phantoms showed regionally varying underestimation of the standardised uptake value (SUV; mean 22 %) due to attenuation caused by the coil. This was improved by implementing the CT-based coil template in the AC (<2 % SUV underestimation). Patient data indicated that including the coil in the AC increased the SUV values in the lesions (21 ± 9 %). Using a dedicated PET/MR breast coil, state-of-the-art MRI was possible. In PET, accurate quantification and image homogeneity could be achieved if a CT-template of this coil was included in the AC for PET image reconstruction. (orig.)

  4. Not the market allowing to quickly pocket money. Siemens/KWU and their commitments in Central and Eastern Europe; ``Kein Markt fuer schnelles Geld``. Das Engagement von Siemens/KWU in Mittel- und Osteuropa

    Energy Technology Data Exchange (ETDEWEB)

    Schwegmann, P.

    1997-05-01

    After the break-up of the Eastern Bloc, Siemens very soon concluded strategic alliances with the big and most qualified Russian power plant manufacturers, busy activities currently focusing on the nuclear sector with retrofitting and safety engineering work in a number of NPPs. Points of main interest are systems analysis, recurrent inspection of primary loop components, and the installation of diagnostic systems for operational monitoring, as well as the instrumentation and control systems. (Orig./RHM) [Deutsch] In Russland ist es Siemens nach der politischen Wende gelungen, mit den groessten und qualifiziertesten Kraftwerksherstellern Russlands strategisch bedeutsame Allianzen einzugehen. Sehr ruehrig ist man auf dem Nuklear-Sektor. So werden gegenwaertig die Sicherheitseinrichtungen einer Reihe von Kernkraftwerken nachgebessert. Schwerpunkte sind dabei Analysen, wiederkehrende Pruefungen an Komponenten der Primaerkreislaeufe sowie die Installation von Diagnosesystemen, Betriebs- und Leittechnik. (orig.)

  5. Detection of recurrent colorectal carcinoma with 18F-FDG positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Scott, A.M.; Berlangieri, S.U.; Zalcberg, J.; Fox, R.; Cebon, J.; McLeish, A.; Thomas, D.; Chan, G.; Tochon-Danguy, H.; Egan, G.F.; McKay, W.J.

    1998-01-01

    Full text: The appropriate surgical management of recurrent colorectal carcinoma is dependent on the accurate detection of possible primary site recurrence and distant spread of disease. The aim of this study was therefore to evaluate the clinical accuracy of 18 F-FDG PET in detecting recurrent colorectal carcinoma. Over a 12-month period we have performed 21 studies in 17 patients (12 M: 5 F, age range 52-73 y) with known or suspected recurrent colorectal carcinoma. All patients underwent PET imaging of the abdomen and pelvis, or whole body imaging, with a whole body PET scanner (Siemens 951/R) following injection of 400 MBq of 18 F-FDG. All PET studies were interpreted with full knowledge of CT findings, and results were compared to subsequent surgical findings, biopsy or follow-up by conventional imaging methods (e.g. CT scan). Of the 21 studies performed, 18 (86%) had abnormal sites of 18 F-FDG uptake; all sites were subsequently confirmed as recurrent colorectal carcinoma. PET identified a total of 30 sites of disease in the pelvis (n = 4), abdomen (n =10), liver (n = 6), thorax (n = 9) and abdominal surgical scar (n 1), and was false negative in one lung lesion. CT scan correctly identified 14 sites as recurrent tumour; 9/12 patients (pts) with equivocal changes on CT scan had recurrent disease identified by PET. In 10 pts with elevated serum CEA but negative or equivocal CT scans, PET correctly identified 8 pts with proven recurrent disease. Previously unsuspected disease was found at six sites by PET. Lesions as small as 1.2 cm proven at surgery were identified with PET. In conclusion, this study shows 18 F-FDG PET to be a promising method for accurate detection of recurrent colorectal carcinoma

  6. The AMFEC: a tool for dedications

    International Nuclear Information System (INIS)

    Pastor Escobar, H.; Gomar Vidal, J.

    2014-01-01

    The process of dedication, consists of a series of activities intended to ensure that a component of commercial grade can be used in applications related with the Security at nuclear facilities. However, in one of the steps of essential dedication, is often the problem defined with certain accuracy the most relevant characteristics or critical acceptance of the component characteristics, which through its verification, give by valid the commercial component for security-related use. Due to lack of information, they can sometimes not be identified clearly, and therefore it is necessary to resort to some alternative method that will allow us to define them, the AMFEC (analysis of failure modes, effects and criticality. (Author)

  7. Dedication of Fermilab's LHC Remote Operations Center

    CERN Multimedia

    Claudia Marcelloni

    2007-01-01

    Fermilab's Remote Operations Center will be dedicated simultaneously at Fermilab in the U.S. and from CMS (Point 5) in Cessy, France. Speakers will include: from the U.S. DOE Undersecretary for Science Raymond Orbach and Fermilab Director Pier Oddone (U.S.); and from CERN Director General Robert Aymar, CMS Spokesperson Jim Virdee, LHC Project Leader Lyn Evans and US CMS Project Manager Joel Butler.

  8. Dedicating Fermilab's Collider

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    It was a bold move to have a fullscale dedication ceremony for the new proton-antiproton Collider at the Fermilab Tevatron on 13 October, two days before the first collisions were seen. However the particles dutifully behaved as required, and over the following weekend the Collider delivered its goods at a total energy of 1600 GeV, significantly boosting the world record for laboratory collisions

  9. Assessing the role of {sup 18}F-FDG PET and {sup 18}F-FDG PET/CT in the diagnosis of soft tissue musculoskeletal malignancies: a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Etchebehere, Elba C. [The University of Texas MD Anderson Cancer Center, Department of Nuclear Medicine, Houston, TX (United States); Sirio Libanes Hospital, Department of Nuclear Medicine, Sao Paulo (Brazil); Hobbs, Brian P.; Milton, Denai R. [The University of Texas MD Anderson Cancer Center, Department of Biostatistics, Houston, TX (United States); Malawi, Osama [The University of Texas MD Anderson Cancer Center, Department of Imaging Physics, Houston, TX (United States); Patel, Shreyaskumar; Benjamin, Robert S. [The University of Texas MD Anderson Cancer Center, Department of Sarcoma Medical Oncology, Houston, TX (United States); Macapinlac, Homer A. [The University of Texas MD Anderson Cancer Center, Department of Nuclear Medicine, Houston, TX (United States)

    2016-05-15

    Twelve years ago a meta-analysis evaluated the diagnostic performance of {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in assessing musculoskeletal soft tissue lesions (MsSTL). Currently, PET/CT has substituted PET imaging; however, there has not been any published meta-analysis on the use of PET/CT or a comparison of PET/CT with PET in the diagnosis of MsSTL. Therefore, we conducted a meta-analysis to identify the current diagnostic performance of {sup 18}F-FDG PET/CT and determine if there is added value when compared to PET. A systematic review of English articles was conducted, and MEDLINE PubMed, the Cochrane Library, and Embase were searched from 1996 to March 2015. Studies exploring the diagnostic accuracy of {sup 18}F-FDG PET/CT (or dedicated PET) compared to histopathology in patients with MsSTL undergoing investigation for malignancy were included. Our meta-analysis included 14 articles composed of 755 patients with 757 soft tissue lesions. There were 451 (60 %) malignant tumors and 306 benign lesions. The {sup 18}F-FDG PET/CT (and dedicated PET) mean sensitivity, specificity, accuracy, positive predictive value, and negative predictive value for diagnosing MsSTL were 0.96 (0.90, 1.00), 0.77 (0.67, 0.86), 0.88 (0.85, 0.91), 0.86 (0.78, 0.94), and 0.91 (0.83, 0.99), respectively. The posterior mean (95 % highest posterior density interval) for the AUC was 0.92 (0.88, 0.96). PET/CT had higher specificity, accuracy, and positive predictive value when compared to a dedicated PET (0.85, 0.89, and 0.91 vs 0.71, 0.85, and 0.82, respectively). {sup 18}F-FDG PET/CT and dedicated PET are both highly accurate in the diagnosis of MsSTL. PET/CT is more accurate and specific and has a higher positive predictive value than PET. (orig.)

  10. An automation of design and modelling tasks in NX Siemens environment with original software - generator module

    Science.gov (United States)

    Zbiciak, M.; Grabowik, C.; Janik, W.

    2015-11-01

    Nowadays the design constructional process is almost exclusively aided with CAD/CAE/CAM systems. It is evaluated that nearly 80% of design activities have a routine nature. These design routine tasks are highly susceptible to automation. Design automation is usually made with API tools which allow building original software responsible for adding different engineering activities. In this paper the original software worked out in order to automate engineering tasks at the stage of a product geometrical shape design is presented. The elaborated software works exclusively in NX Siemens CAD/CAM/CAE environment and was prepared in Microsoft Visual Studio with application of the .NET technology and NX SNAP library. The software functionality allows designing and modelling of spur and helicoidal involute gears. Moreover, it is possible to estimate relative manufacturing costs. With the Generator module it is possible to design and model both standard and non-standard gear wheels. The main advantage of the model generated in such a way is its better representation of an involute curve in comparison to those which are drawn in specialized standard CAD systems tools. It comes from fact that usually in CAD systems an involute curve is drawn by 3 points that respond to points located on the addendum circle, the reference diameter of a gear and the base circle respectively. In the Generator module the involute curve is drawn by 11 involute points which are located on and upper the base and the addendum circles therefore 3D gear wheels models are highly accurate. Application of the Generator module makes the modelling process very rapid so that the gear wheel modelling time is reduced to several seconds. During the conducted research the analysis of differences between standard 3 points and 11 points involutes was made. The results and conclusions drawn upon analysis are shown in details.

  11. Duplex-cladding: Siemens answer to the requirements of extended burnup in PWRs

    International Nuclear Information System (INIS)

    Van Swam, L.F.; Sell, H.J.; Eberle, R.; Seibold, A.

    1994-01-01

    One important goal of nuclear fuel development is to increase the cost-effectiveness of the nuclear fuel cycle by burnup extension. A prerequisite for this goal is a cladding tube with high resistance to corrosion under the operating conditions of modern PWRs. Therefore, in the early eighties Siemens started to investigate the material behaviour of Zirconium based alloys also outside the composition range of Zry-4. The examination included out-of-pile corrosion testing in water and steam, with and without chemical addition, such as LiOH, in-pile testing of path finder fuel rods in a hot PWR up to 80 MWd/kgU and the investigation of mechanical behaviour, growth and creep under normal and the postulated conditions of a loss-of-coolant accident (LOCA). The evaluation of in-pile and out-of-pile experiments on alternative Zr-alloys revealed that improvements in corrosion resistance are frequently accompanied by undesirable changes in material properties which affect mechanical design and LOCA behaviour. To fulfill all requirements - the mechanical and corrosion related ones - and to retain the large experience base with Zry-4, a DUPLEX cladding was selected. The selected ELS DUPLEX cladding consists of a Zircaloy-4 tubing with a thin outer layer of an Extra Low tin (Sn) Zr-alloy. The ELS layer improves the stability against LiOH and allows operation with voided coolant. This advanced product has been engineered for use in highly enriched fuel assemblies in high efficiency plants operating with low neutron leakage core management and high coolant temperatures. It has become the accepted fuel rod cladding for many plants in Germany, Spain and Switzerland. (authors). 6 figs., 2 refs

  12. Dosimetry verifications of the physical parameters of virtual wedge on a Siemens accelerator

    International Nuclear Information System (INIS)

    Zhong Heli; Li Xiaodong; Li Longxing

    2002-01-01

    Objective: To verify the wedge angle of virtual wedge and the relation between wedge factor and beam energy, field size, wedge angle and to study the difference in percent depth dose (PDD) of virtual wedge field, hard wedge field and open field. Methods: Using wedge angle and wedge factor of 15 degree, 30 degree, 45 degree and 60 degree virtual wedge of Siemens Mevatron 6 MV and Primus 8 MV, 18 MV X rays were measured by RFA-plus 3D water phantom and RK finger chamber the PDD of the virtual wedge field, hard wedge field and open field were measured by Kodak XV-2 verifying film and FDM-300 film dosimeter. These PDDs were normalized to Dmax then compared. Results: There was good conformation between virtual wedge measured by four point method and set value. The virtual wedge was almost equal to 1, with a maximal variation of 0.031 no matter what the value of beam energy, field size or wedge angle was. Generally, for certain energy and field size, the wedge factor of larger wedge angle was slightly larger than smaller wedge angle. For certain energy and wedge angle, the wedge factor of larger field was also a little larger than smaller field. The PDD of virtual wedge field was similar to that of open field. Conclusions: The four point method measurement for virtual wedge angle is good for daily QA. Radiotherapy of virtual wedge field is not only simpler than hard wedge field, but also spares the beam output. The PDD conferment between virtual field and open field simplifies radiation treatment planning and increases the accuracy of wedge field therapy

  13. Modelling the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner

    International Nuclear Information System (INIS)

    Amin, A T Mohd; Rahni, A A Abd

    2017-01-01

    Reconstructing large volumetric 3D images with minimal radiation dosage exposure with reduced scanning time has been one of the main objectives in the advancement of CT development. One of its advancement is the introduction of multi-slice arc detector geometry from a cone-beam source in third generation scanners. In solving this complex geometry, apart from the known vast computations in CT image reconstruction due to large CT images, iterative reconstruction methods are preferred compared to analytic methods due to its flexibility in image reconstruction. A scanner of interest that has this type of geometry is the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner , which has a total of 32 slices with 672 detector elements on each slice. In this paper, the scanner projection is modelled via the intersecting lengths between each ray (exhibited from the source to the detector elements) with the scanned image voxels, which are evaluated using the classical Siddon’s algorithm to generate the system matrix, H . This is a prerequisite to perform various iterative reconstruction methods, which involves solving the inverse problem arising from the linear equation: S = H· I; where S is the projections produced from the image, I. Due to the ‘cone-beam geometry’ along the z -axis, the effective field-of-view (FOV) with voxel dimensions (0.4×0.4×0.4) mm 3 is 512×512×32 voxels. The scanner model is demonstrated by reconstructing an image from simulated projections using the analytic Feldkamp-Davis-Kress (FDK) method against basic iterative image reconstruction methods. (paper)

  14. Not the market allowing to quickly pocket money. Siemens/KWU and their commitments in Central and Eastern Europe

    International Nuclear Information System (INIS)

    Schwegmann, P.

    1997-01-01

    After the break-up of the Eastern Bloc, Siemens very soon concluded strategic alliances with the big and most qualified Russian power plant manufacturers, busy activities currently focusing on the nuclear sector with retrofitting and safety engineering work in a number of NPPs. Points of main interest are systems analysis, recurrent inspection of primary loop components, and the installation of diagnostic systems for operational monitoring, as well as the instrumentation and control systems. (Orig./RHM) [de

  15. Solar energy: Shell buys up the shares of Siemens and E.ON in their joint-venture

    International Nuclear Information System (INIS)

    Anon.

    2002-01-01

    The anglo-Dutch petroleum firm Royal Dutch/Shell has announced its intention to buy up the shares of its German partners Siemens and E.ON in their joint-venture specialized in the solar energy. If the buying up is authorized by the proper authorities, the firm will be held at 100% by Shell. Shell intends indeed to invest 500 millions to 1 milliard of dollars on 5 years in the development of renewable energies. (O.M.)

  16. Investigation of the mechanical performance of Siemens linacs components during arc: gantry, MLC, and electronic portal imaging device

    Directory of Open Access Journals (Sweden)

    Rowshanfarzad P

    2015-11-01

    Full Text Available Pejman Rowshanfarzad,1 Peter Häring,2 Hans L Riis,3 Sune J Zimmermann,3 Martin A Ebert1,4 1School of Physics, The University of Western Australia, Crawley, WA, Australia; 2German Cancer Research Center (DKFZ, Medical Physics in Radiation Oncology, Heidelberg, Germany; 3Radiofysisk Laboratorium, Odense University Hospital, Odense C, Denmark; 4Department of Radiation Oncology, Sir Charles Gairdner Hospital, Nedlands, WA, Australia Background: In radiotherapy treatments, it is crucial to monitor the performance of linac components including gantry, collimation system, and electronic portal imaging device (EPID during arc deliveries. In this study, a simple EPID-based measurement method is suggested in conjunction with an algorithm to investigate the stability of these systems at various gantry angles with the aim of evaluating machine-related errors in treatments. Methods: The EPID sag, gantry sag, changes in source-to-detector distance (SDD, EPID and collimator skewness, EPID tilt, and the sag in leaf bank assembly due to linac rotation were separately investigated by acquisition of 37 EPID images of a simple phantom with five ball bearings at various gantry angles. A fast and robust software package was developed for automated analysis of image data. Three Siemens linacs were investigated. Results: The average EPID sag was within 1 mm for all tested linacs. Two machines showed >1 mm gantry sag. Changes in the SDD values were within 7.5 mm. EPID skewness and tilt values were <1° in all machines. The maximum sag in leaf bank assembly was <1 mm. Conclusion: The method and software developed in this study provide a simple tool for effective investigation of the behavior of Siemens linac components with gantry rotation. Such a comprehensive study has been performed for the first time on Siemens machines. Keywords: linac, Siemens, arc, sag, EPID, gantry

  17. Automatic attenuator upgrade for a Siemens D500 diffractometer via a generic software library to overcome hardware limitations

    International Nuclear Information System (INIS)

    Mayr, Sina; Randau, Christian; Kreuzpaintner, Wolfgang

    2017-01-01

    A proxy software was developed which allows the Siemens D500 x-ray diffractometer to be upgraded with add-ons that have never been officially available for it. For demonstration, we designed and integrated an automatic attenuator option and demonstrated the feasibility of our upgrade path by typical comparative x-ray measurements, which would usually saturate the x-ray detector, if no attenuator is used.

  18. Automatic attenuator upgrade for a Siemens D500 diffractometer via a generic software library to overcome hardware limitations

    Energy Technology Data Exchange (ETDEWEB)

    Mayr, Sina, E-mail: sina.mayr@frm2.tum.de [Technische Universität München, Physik-Department E21, James-Franck-Str. 1, 85748 Garching (Germany); Randau, Christian [Georg-August-Universität Göttingen, Fakultät für Geowissenschaften und Geologie, Abteilung Isotopengeologie Außenstelle MLZ (FRM II), Lichtenbergstr. 1, 85748 Garching (Germany); Kreuzpaintner, Wolfgang [Technische Universität München, Physik-Department E21, James-Franck-Str. 1, 85748 Garching (Germany)

    2017-05-21

    A proxy software was developed which allows the Siemens D500 x-ray diffractometer to be upgraded with add-ons that have never been officially available for it. For demonstration, we designed and integrated an automatic attenuator option and demonstrated the feasibility of our upgrade path by typical comparative x-ray measurements, which would usually saturate the x-ray detector, if no attenuator is used.

  19. Value of FDG-PET vs MRI/CT in detection and staging of early uterine cervical cancer

    International Nuclear Information System (INIS)

    Kluge, P.; Kratzsch, A.; Horn, L.; Schmidt, F.; Einkel, J.; Sabri, O.

    2003-01-01

    This prospective study was performed to define the efficiency of FDG-PET in detecting primaries and in preoperatively assessing lymph node metastases of cervical cancer. Forty one patients with cervical cancer were investigated with PET (370 MBq F-18-FDG, Siemens ECAT EXACT HR+, visual evaluation) and MRI prior radical hysterectomy with pelvic, and additionally 12 cases paraortal, lymphadenectomies. Histopathological evaluation verified in all cases the evidence of cervical cancer except in one case, where the tumor was completely removed by conisation procedure. Sensitivity of PET and MRI were 95% and 85%, respectively. In 16/82 pelvic lymph node sites metastases were histologically detected (7 x micrometastases). Sensitivity, specificity, positive positive and negative predictive value were 50%, 85%, 44% and 88% for PET and 31%, 90%, 40% and 86% for MRI. Out of the 12 cases with dissection of paraortal lymph nodes, metastases were found histologically in 3 cases. PET detected 2/3 truly with no false positive result while CT detected 0/3 cases with no false positive findings. It is concluded that PET can detect cervical cancer with high accuracy. The accuracy of PET and MRI was similar for detection of pelvic metastases. Both methods have limited sensitivity due to the high incidence of micrometastases. PET was more accurate than CT in detection of paraortal metastases

  20. Thoracic staging in lung cancer: prospective comparison of 18F-FDG PET/MR imaging and 18F-FDG PET/CT.

    Science.gov (United States)

    Heusch, Philipp; Buchbender, Christian; Köhler, Jens; Nensa, Felix; Gauler, Thomas; Gomez, Benedikt; Reis, Henning; Stamatis, Georgios; Kühl, Hilmar; Hartung, Verena; Heusner, Till A

    2014-03-01

    Therapeutic decisions in non-small cell lung cancer (NSCLC) patients depend on the tumor stage. PET/CT with (18)F-FDG is widely accepted as the diagnostic standard of care. The purpose of this study was to compare a dedicated pulmonary (18)F-FDG PET/MR imaging protocol with (18)F-FDG PET/CT for primary and locoregional lymph node staging in NSCLC patients using histopathology as the reference. Twenty-two patients (12 men, 10 women; mean age ± SD, 65.1 ± 9.1 y) with histopathologically confirmed NSCLC underwent (18)F-FDG PET/CT, followed by (18)F-FDG PET/MR imaging, including a dedicated pulmonary MR imaging protocol. T and N staging according to the seventh edition of the American Joint Committee on Cancer staging manual was performed by 2 readers in separate sessions for (18)F-FDG PET/CT and PET/MR imaging, respectively. Results from histopathology were used as the standard of reference. The mean and maximum standardized uptake value (SUV(mean) and SUV(max), respectively) and maximum diameter of the primary tumor was measured and compared in (18)F-FDG PET/CT and PET/MR imaging. PET/MR imaging and (18)F-FDG PET/CT agreed on T stages in 16 of 16 of patients (100%). All patients were correctly staged by (18)F-FDG PET/CT and PET/MR (100%), compared with histopathology. There was no statistically significant difference between (18)F-FDG PET/CT and (18)F-FDG PET/MR imaging for lymph node metastases detection (P = 0.48). For definition of thoracic N stages, PET/MR imaging and (18)F-FDG PET/CT were concordant in 20 of 22 patients (91%). PET/MR imaging determined the N stage correctly in 20 of 22 patients (91%). (18)F-FDG PET/CT determined the N stage correctly in 18 of 22 patients (82%). The mean differences for SUV(mean) and SUV(max) of NSCLC in (18)F-FDG PET/MR imaging and (18)F-FDG PET/CT were 0.21 and -5.06. These differences were not statistically significant (P > 0.05). The SUV(mean) and SUV(max) measurements derived from (18)F-FDG PET/CT and (18)F-FDG PET

  1. Investigation of the mechanical performance of Siemens linacs components during arc: gantry, MLC, and electronic portal imaging device.

    Science.gov (United States)

    Rowshanfarzad, Pejman; Häring, Peter; Riis, Hans L; Zimmermann, Sune J; Ebert, Martin A

    2015-01-01

    In radiotherapy treatments, it is crucial to monitor the performance of linac components including gantry, collimation system, and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method is suggested in conjunction with an algorithm to investigate the stability of these systems at various gantry angles with the aim of evaluating machine-related errors in treatments. The EPID sag, gantry sag, changes in source-to-detector distance (SDD), EPID and collimator skewness, EPID tilt, and the sag in leaf bank assembly due to linac rotation were separately investigated by acquisition of 37 EPID images of a simple phantom with five ball bearings at various gantry angles. A fast and robust software package was developed for automated analysis of image data. Three Siemens linacs were investigated. The average EPID sag was within 1 mm for all tested linacs. Two machines showed >1 mm gantry sag. Changes in the SDD values were within 7.5 mm. EPID skewness and tilt values were <1° in all machines. The maximum sag in leaf bank assembly was <1 mm. The method and software developed in this study provide a simple tool for effective investigation of the behavior of Siemens linac components with gantry rotation. Such a comprehensive study has been performed for the first time on Siemens machines.

  2. Implementation and application of simulation platform of PET based on GATE

    International Nuclear Information System (INIS)

    Zhang Bin; Zhao Shujun; Zhang Shixun; Liu Haojia

    2010-01-01

    Positron emission tomography (PET) is a tool for obtaining functional image in vivo and GATE is a dedicated software for PET/SPECT simulation based on Mentor Carlo Method. It encapsulates the Geant4 libraries to achieve a modular and provides a number of new characteristics. In practice, a simulation platform of PET has been builded employing GATE based on Ubuntu operating system, including many keys and skills in the process. We have exploited benchmark PET, a testing example in GATE, and implemented PET scanner simulation in the end. Through analyzing the simulation data, the result demonstrate that predictive goal has been reached. The work provides the foundation for investigating PET scanner and optimizing the algorithm of tomograph image reconstruction. (authors)

  3. Simulation study comparing the helmet-chin PET with a cylindrical PET of the same number of detectors

    Science.gov (United States)

    Ahmed, Abdella M.; Tashima, Hideaki; Yoshida, Eiji; Nishikido, Fumihiko; Yamaya, Taiga

    2017-06-01

    There is a growing interest in developing brain PET scanners with high sensitivity and high spatial resolution for early diagnosis of neurodegenerative diseases and studies of brain functions. Sensitivity of the PET scanner can be improved by increasing the solid angle. However, conventional PET scanners are designed based on a cylindrical geometry, which may not be the most efficient design for brain imaging in terms of the balance between sensitivity and cost. We proposed a dedicated brain PET scanner based on a hemispheric shape detector and a chin detector (referred to as the helmet-chin PET), which is designed to maximize the solid angle by increasing the number of lines-of-response in the hemisphere. The parallax error, which PET scanners with a large solid angle tend to have, can be suppressed by the use of depth-of-interaction detectors. In this study, we carry out a realistic evaluation of the helmet-chin PET using Monte Carlo simulation based on the 4-layer GSO detector which consists of a 16  ×  16  ×  4 array of crystals with dimensions of 2.8  ×  2.8  ×  7.5 mm3. The purpose of this simulation is to show the gain in imaging performance of the helmet-chin PET compared with the cylindrical PET using the same number of detectors in each configuration. The sensitivity of the helmet-chin PET evaluated with a cylindrical phantom has a significant increase, especially at the top of the (field-of-view) FOV. The peak-NECR of the helmet-chin PET is 1.4 times higher compared to the cylindrical PET. The helmet-chin PET provides relatively low noise images throughout the FOV compared to the cylindrical PET which exhibits enhanced noise at the peripheral regions. The results show the helmet-chin PET can significantly improve the sensitivity and reduce the noise in the reconstructed images.

  4. Solitary pulmonary nodules: accuracy and cost-effectiveness of sodium iodide FDG-PET using Australian data

    International Nuclear Information System (INIS)

    Keith, C.J.; Miles, K.A.; Griffiths, M.R.; Wong, D.; Pitman, A.G.; Hicks, R.J.

    2002-01-01

    This study uses Australian data to confirm the accuracy of dedicated sodium iodide (NaI) fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) in evaluating indeterminate solitary pulmonary nodules (SPNs) and to determine the conditions under which PET could play a cost-effective role in this evaluation. Ninety-two patients from two Australian hospitals in different states underwent FDG-PET for evaluation of an SPN. Observed values for prior probability of malignancy and diagnostic accuracy of PET were applied to previously published decision tree models using published Australian health care costs. The accuracy of FDG-PET was 93% with a sensitivity of 92% and a specificity of 95%. The prior probability of malignancy (0.54), PET sensitivity and PET specificity indicated cost savings per patient of up to EUR 455 (A$ 774) based on a PET cost of EUR 706 (A$ 1,200). PET would remain cost-effective for levels of prior probability up to 0.8-0.9 and a PET cost of EUR 736-1,161 (A$ 1,252-A$ 1,974). It is concluded that NaI PET is accurate, cost saving and cost-effective for the characterisation of indeterminate pulmonary nodules in Australia. Comparison with previous reports from the United States confirms that FDG-PET can remain cost-effective despite population differences in medical costs, disease prevalence and PET diagnostic performance. (orig.)

  5. PET and SPECT of neurobiological systems

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Gent Univ. (Belgium). Dept. of Nuclear Medicine; Otte, Andreas [Univ. of Applied Sciences, Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-04-01

    Addresses a variety of aspects of neurotransmission in the brain. Details the latest results in probe development. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT of Neurobiological Systems combines the expertise of renowned authors whose dedication to the development of novel probes and techniques for the investigation of neurobiological systems has achieved international recognition. Various aspects of neurotransmission in the brain are discussed, such as visualization and quantification of (more than 20 different) neuroreceptors, neuroinflammatory markers, transporters, and enzymes as well as neurotransmitter synthesis, ?-amyloid deposition, cerebral blood flow, and the metabolic rate of glucose. The latest results in probe development are also detailed. Most chapters are written jointly by radiochemists and nuclear medicine specialists to ensure a multidisciplinary approach. This state of the art compendium will be valuable to anyone in the field of clinical or preclinical neuroscience, from the radiochemist and radiologist/nuclear medicine specialist to the interested neurobiologist and general practitioner. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences. Other volumes focus on PET and SPECT in psychiatry and PET and SPECT in neurology''.

  6. PET radiation exposure control for nurses

    International Nuclear Information System (INIS)

    Kawabata, Yumiko; Kikuta, Daisuke; Anzai, Taku

    2005-01-01

    Recently, the number of clinical PET centers is increasing all over Japan. For this reason, the monitoring and control of radiation exposure of employees, especially nurses, in PET-dedicated clinics and institutions are becoming very important issues for their health. We measured the radiation exposure doses of the nurses working at Nishidai Diagnostic Imaging Center, and analyzed the exposure data obtained from them. The exposure doses of the nurses were found to be 4.8 to 7.1 mSv between April 2003 and March 2004. We found that the nurses were mostly exposed to radiation when they had to have contact with patients received an FDG injection or they had trouble with the FDG automatic injection system. To keep radiation exposure of nurses to a minimum we reconfirmed that a proper application of the three principles of protection against radiation exposure was vital. (author)

  7. Development of compact DOI-measurable PET detectors for simultaneous PET/MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Yiping; Sun, Xishan [University of Texas MD Anderson Cancer Center (United States); Lou, Kai [Rice University (United States)

    2015-05-18

    It is critically needed yet challenging to develop compact PET detectors with high sensitivity and uniform, high imaging resolution for improving the performance of simultaneous PET/MR imaging, particularly for an integrated/inserted small-bore system. Using the latest “edge-less” SiPM arrays for DOI measurement using the design of dual-ended-scintillator readout, we developed several compact PET detectors suited for PET/MR imaging. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together along all sides to form a large detector panel. Detectors with 1.5x1.5 and 2.0x2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or capacitor-based signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables to dedicated ASIC frontend electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition positioned outside the MRI scanner for coincidence event selection. Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ~18% and 2.8 ns energy and timing resolutions, and around 2-3 mm DOI resolution. A large size detector panel can be scaled up with these modular detectors and different PET systems can be flexibly configured with the scalable readout electronics and data acquisition, providing an important design advantage for different system and application requirements. It is expected that standard shielding of detectors, electronics and signal transfer lines can be applied for simultaneous PET/MR imaging applications, with desired DOI measurement capability to enhance the PET performance and image quality.

  8. Development of compact DOI-measurable PET detectors for simultaneous PET/MR Imaging

    International Nuclear Information System (INIS)

    Shao, Yiping; Sun, Xishan; Lou, Kai

    2015-01-01

    It is critically needed yet challenging to develop compact PET detectors with high sensitivity and uniform, high imaging resolution for improving the performance of simultaneous PET/MR imaging, particularly for an integrated/inserted small-bore system. Using the latest “edge-less” SiPM arrays for DOI measurement using the design of dual-ended-scintillator readout, we developed several compact PET detectors suited for PET/MR imaging. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together along all sides to form a large detector panel. Detectors with 1.5x1.5 and 2.0x2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or capacitor-based signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables to dedicated ASIC frontend electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition positioned outside the MRI scanner for coincidence event selection. Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ~18% and 2.8 ns energy and timing resolutions, and around 2-3 mm DOI resolution. A large size detector panel can be scaled up with these modular detectors and different PET systems can be flexibly configured with the scalable readout electronics and data acquisition, providing an important design advantage for different system and application requirements. It is expected that standard shielding of detectors, electronics and signal transfer lines can be applied for simultaneous PET/MR imaging applications, with desired DOI measurement capability to enhance the PET performance and image quality.

  9. Selecting Safe Pets (For Parents)

    Science.gov (United States)

    ... supplies (pet bowls, pet bed, leash, etc.) as gifts, then selecting the pet as a family. That way, everyone has time to really think about whether your family is ready for a pet. Key Questions Before adopting or purchasing any pet, talk to all family members, discuss ...

  10. Pet-Related Infections.

    Science.gov (United States)

    Day, Michael J

    2016-11-15

    Physicians and veterinarians have many opportunities to partner in promoting the well-being of people and their pets, especially by addressing zoonotic diseases that may be transmitted between a pet and a human family member. Common cutaneous pet-acquired zoonoses are dermatophytosis (ringworm) and sarcoptic mange (scabies), which are both readily treated. Toxoplasmosis can be acquired from exposure to cat feces, but appropriate hygienic measures can minimize the risk to pregnant women. Persons who work with animals are at increased risk of acquiring bartonellosis (e.g., cat-scratch disease); control of cat fleas is essential to minimize the risk of these infections. People and their pets share a range of tick-borne diseases, and exposure risk can be minimized with use of tick repellent, prompt tick removal, and appropriate tick control measures for pets. Pets such as reptiles, amphibians, and backyard poultry pose a risk of transmitting Salmonella species and are becoming more popular. Personal hygiene after interacting with these pets is crucial to prevent Salmonella infections. Leptospirosis is more often acquired from wildlife than infected dogs, but at-risk dogs can be protected with vaccination. The clinical history in the primary care office should routinely include questions about pets and occupational or other exposure to pet animals. Control and prevention of zoonoses are best achieved by enhancing communication between physicians and veterinarians to ensure patients know the risks of and how to prevent zoonoses in themselves, their pets, and other people.

  11. Ford F250 Dedicated CNG Pickup

    International Nuclear Information System (INIS)

    Eudy, Leslie

    1999-01-01

    The U.S. Department of Energy (DOE) is encouraging the use of alternative fuels and alternative fuel vehicles (AFVs). To support this activity, DOE has directed the National Renewable Energy Laboratory (NREL) to conduct projects to evaluate the performance and acceptability of light-duty AFVs. In this study, we tested a pair of 1998 Ford F-250 pickups: one dedicated compressed natural gas (CNG) model and a gasoline model as closely matched as possible. Each vehicle was run through a series of tests to evaluate acceleration, fuel economy, braking, and cold-start capabilities, as well as more subjective performance indicators such as handling, climate control, and noise

  12. Introduction of the new process and quality control methods in fuel fabrication at Siemens/ANF

    International Nuclear Information System (INIS)

    Rogge, K.T.; Fickers, H.H.; Doerr, W.

    2000-01-01

    system and efforts assure products of high quality and contribute herewith to the safe and economical performance of the fuel supplied by Siemens/ANF. (author)

  13. A method of computer aided design with self-generative models in NX Siemens environment

    Science.gov (United States)

    Grabowik, C.; Kalinowski, K.; Kempa, W.; Paprocka, I.

    2015-11-01

    Currently in CAD/CAE/CAM systems it is possible to create 3D design virtual models which are able to capture certain amount of knowledge. These models are especially useful in an automation of routine design tasks. These models are known as self-generative or auto generative and they can behave in an intelligent way. The main difference between the auto generative and fully parametric models consists in the auto generative models ability to self-organizing. In this case design model self-organizing means that aside from the possibility of making of automatic changes of model quantitative features these models possess knowledge how these changes should be made. Moreover they are able to change quality features according to specific knowledge. In spite of undoubted good points of self-generative models they are not so often used in design constructional process which is mainly caused by usually great complexity of these models. This complexity makes the process of self-generative time and labour consuming. It also needs a quite great investment outlays. The creation process of self-generative model consists of the three stages it is knowledge and information acquisition, model type selection and model implementation. In this paper methods of the computer aided design with self-generative models in NX Siemens CAD/CAE/CAM software are presented. There are the five methods of self-generative models preparation in NX with: parametric relations model, part families, GRIP language application, knowledge fusion and OPEN API mechanism. In the paper examples of each type of the self-generative model are presented. These methods make the constructional design process much faster. It is suggested to prepare this kind of self-generative models when there is a need of design variants creation. The conducted research on assessing the usefulness of elaborated models showed that they are highly recommended in case of routine tasks automation. But it is still difficult to distinguish

  14. Dedicated Filter for Robust Occupancy Grid Mapping

    Directory of Open Access Journals (Sweden)

    KS Nagla

    2015-03-01

    Full Text Available Sensor based perception of the environment is an emerging area of the mobile robot research where sensors play a pivotal role. For autonomous mobile robots, the fundamental requirement is the convergent of the range information in to high level internal representation. Internal representation in the form of occupancy grid is commonly used in autonomous mobile robots due to its various advantages. There are several sensors such as vision sensor, laser rage finder, and ultrasonic and infrared sensors etc. play roles in mapping. However the sensor information failure, sensor inaccuracies, noise, and slow response are the major causes of an error in the mapping. To improve the reliability of the mobile robot mapping multisensory data fusion is considered as an optimal solution. This paper presents a novel architecture of sensor fusion frame work in which a dedicated filter (DF is proposed to increase the robustness of the occupancy grid for indoor environment. The technique has been experimentally verified for different indoor test environments. The proposed configuration shows improvement in the occupancy grid with the implementation of dedicated filters.

  15. Dedicated low-field MRI in mice

    International Nuclear Information System (INIS)

    Choquet, P; Breton, E; Goetz, C; Constantinesco, A; Marin, C

    2009-01-01

    The rationale of this work is to point out the relevance of in vivo MR images of mice obtained using a dedicated low-field system. For this purpose a small 0.1 T water-cooled electro-magnet and solenoidal radio frequency (RF) transmit-receive coils were used. All MR images were acquired in three-dimensional (3D) mode. An isolation cell was designed allowing easy placement of the RF coils and simple delivery of gaseous anesthesia as well as warming of the animal. Images with and without contrast agent were obtained in total acquisition times on the order of half an hour to four hours on normal mice as well as on animals bearing tumors. Typical in plane pixel dimensions range from 200 x 200 to 500 x 500 μm 2 with slice thicknesses ranging between 0.65 and 1.50 mm. This work shows that, besides light installation and low cost, dedicated low-field MR systems are suitable for small rodents imaging, opening this technique even to small research units.

  16. Dedicated low-field MRI in mice

    Science.gov (United States)

    Choquet, P.; Breton, E.; Goetz, C.; Marin, C.; Constantinesco, A.

    2009-09-01

    The rationale of this work is to point out the relevance of in vivo MR images of mice obtained using a dedicated low-field system. For this purpose a small 0.1 T water-cooled electro-magnet and solenoidal radio frequency (RF) transmit-receive coils were used. All MR images were acquired in three-dimensional (3D) mode. An isolation cell was designed allowing easy placement of the RF coils and simple delivery of gaseous anesthesia as well as warming of the animal. Images with and without contrast agent were obtained in total acquisition times on the order of half an hour to four hours on normal mice as well as on animals bearing tumors. Typical in plane pixel dimensions range from 200 × 200 to 500 × 500 µm2 with slice thicknesses ranging between 0.65 and 1.50 mm. This work shows that, besides light installation and low cost, dedicated low-field MR systems are suitable for small rodents imaging, opening this technique even to small research units.

  17. Pets and the immunocompromised person

    Science.gov (United States)

    ... marrow transplant patients and pets; Chemotherapy patients and pets ... Centers for Disease Control and Prevention website. Healthy pets healthy people. www.cdc.gov/healthypets . Updated July 19, 2016. ...

  18. Sensory analysis of pet foods.

    Science.gov (United States)

    Koppel, Kadri

    2014-08-01

    Pet food palatability depends first and foremost on the pet and is related to the pet food sensory properties such as aroma, texture and flavor. Sensory analysis of pet foods may be conducted by humans via descriptive or hedonic analysis, pets via acceptance or preference tests, and through a number of instrumental analysis methods. Sensory analysis of pet foods provides additional information on reasons behind palatable and unpalatable foods as pets lack linguistic capabilities. Furthermore, sensory analysis may be combined with other types of information such as personality and environment factors to increase understanding of acceptable pet foods. Most pet food flavor research is proprietary and, thus, there are a limited number of publications available. Funding opportunities for pet food studies would increase research and publications and this would help raise public awareness of pet food related issues. This mini-review addresses current pet food sensory analysis literature and discusses future challenges and possibilities. © 2014 Society of Chemical Industry.

  19. The establishment of the method of three dimension volumetric fusion of emission and transmission images for PET imaging

    International Nuclear Information System (INIS)

    Zhang Xiangsong; He Zuoxiang

    2004-01-01

    Objective: To establish the method of three dimension volumetric fusion of emission and transmission images for PET imaging. Methods: The volume data of emission and transmission images acquired with Siemens ECAT HR + PET scanner were transferred to PC computer by local area network. The PET volume data were converted into 8 bit byte type, and scaled to the range of 0-255. The data coordinates of emission and transmission images were normalized by three-dimensional coordinate conversion in the same way. The images were fused with the mode of alpha-blending. The accuracy of image fusion was confirmed by its clinical application in 13 cases. Results: The three dimension volumetric fusion of emission and transmission images clearly displayed the silhouette and anatomic configuration in chest, including chest wall, lung, heart, mediastinum, et al. Forty-eight lesions in chest in 13 cases were accurately located by the image fusion. Conclusions: The volume data of emission and transmission images acquired with Siemens ECAT HR + PET scanner have the same data coordinate. The three dimension fusion software can conveniently used for the three dimension volumetric fusion of emission and transmission images, and also can correctly locate the lesions in chest

  20. Iterative reconstruction using a Monte Carlo based system transfer matrix for dedicated breast positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Krishnendu [Ohio Medical Physics Consulting, Dublin, Ohio 43017 (United States); Straus, Kenneth J.; Glick, Stephen J. [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States); Chen, Yu. [Department of Radiation Oncology, Columbia University, New York, New York 10032 (United States)

    2014-08-28

    To maximize sensitivity, it is desirable that ring Positron Emission Tomography (PET) systems dedicated for imaging the breast have a small bore. Unfortunately, due to parallax error this causes substantial degradation in spatial resolution for objects near the periphery of the breast. In this work, a framework for computing and incorporating an accurate system matrix into iterative reconstruction is presented in an effort to reduce spatial resolution degradation towards the periphery of the breast. The GATE Monte Carlo Simulation software was utilized to accurately model the system matrix for a breast PET system. A strategy for increasing the count statistics in the system matrix computation and for reducing the system element storage space was used by calculating only a subset of matrix elements and then estimating the rest of the elements by using the geometric symmetry of the cylindrical scanner. To implement this strategy, polar voxel basis functions were used to represent the object, resulting in a block-circulant system matrix. Simulation studies using a breast PET scanner model with ring geometry demonstrated improved contrast at 45% reduced noise level and 1.5 to 3 times resolution performance improvement when compared to MLEM reconstruction using a simple line-integral model. The GATE based system matrix reconstruction technique promises to improve resolution and noise performance and reduce image distortion at FOV periphery compared to line-integral based system matrix reconstruction.

  1. Development of a liquid xenon Compton telescope dedicated to functional medical imaging

    International Nuclear Information System (INIS)

    Grignon, C.

    2007-12-01

    Functional imaging is a technique used to locate in three dimensions the position of a radiotracer previously injected in a patient. The two main modalities used for a clinical application to detect tumors, the SPECT and the PET, use solid scintillators as a detection medium. The objective of this thesis was to investigate the possibility of using liquid xenon in order to benefit from the intrinsic properties of this medium in functional imaging. The feasibility study of such a device has been performed by taking into account the technical difficulties specific to the liquid xenon. First of all, simulations of a liquid xenon PET has been performed using Monte-Carlo methods. The results obtained with a large liquid xenon volume are promising : we can expect a reduction of the injected activity of radiotracer, an improvement of the spatial resolution of the image and a parallax free camera. The second part of the thesis was focused on the development of a new concept of medical imaging, the three gamma imaging, based on the use of a new emitter: the 44 scandium. Associated to a classical PET camera, the Compton telescope is used to infer the incoming direction of the third gamma ray by triangulation. Therefore, it is possible to reconstruct the position of each emitter in three dimensions. This work convinced the scientific community to support the construction and characterization of a liquid xenon Compton telescope. The first camera dedicated to small animal imaging should then be operational in 2009. (author)

  2. Quality control in PET/CT systems. Experiences and requirements

    International Nuclear Information System (INIS)

    Geworski, Lilli; Fitz, Eduard; Knoop, Bernd; Karwarth, Cornelia; Plotkin, Michail

    2010-01-01

    Today, in most cases PET examinations are performed using PET/CT hybrid systems. While acceptance testing and routine control of the basic modalities PET and CT, respectively, are described by appropriate regulations, corresponding instructions with regard to the interface connecting both are still missing. This interface includes the adjustment of gantries and patient bed to each other as well as the energy scaling of attenuation coefficients from CT energy to 511 keV. Measurements checking the mechanical adjustment (determination of off-set parameters) are performed following manufacturer's recommendation, with a typical frequency twice a year. On a Biograph 16 (Siemens, Inc.), these measurements were systematically extended to a weekly frequency over an observation period of 10 months, supplemented by measurements with additional load to the patient bed (up to 135 kg), and different vertical bed positions. The results show, that for the construction tested additional off-set measurements for routine control extending well beyond manufacturer's recommendation are not necessary. The energy scaling of attenuation coefficients is depending on methodological aspects and software implementation, and therefore is not part of routine control. On the contrary, the development of appropriate methods for acceptance testing to assess and to determine the mechanical adjustment in all its degrees of freedom as well as the accuracy of attenuation corrected emission data is urgently needed. (orig.)

  3. Multiparametric evaluation by simultaneous PET-MRI examination in patients with histologically proven laryngeal cancer.

    Science.gov (United States)

    Cavaliere, Carlo; Romeo, Valeria; Aiello, Marco; Mesolella, Massimo; Iorio, Brigida; Barbuto, Luigi; Cantone, Elena; Nicolai, Emanuele; Covello, Mario

    2017-03-01

    To evaluate the relationship between metabolic 18Fluoro-Deoxyglucose-Positron Emission Tomography (18FDG/PET) and morpho-functional parameters derived by Magnetic Resonance Imaging (MRI) in patients with histologically proven laryngeal cancer. To assess the clinical impact of PET/MRI examination on patient's staging and treatment planning. 16 patients with histologically proven laryngeal cancer were enrolled and underwent whole body PET/CT followed by a dedicated PET/MRI of the head/neck region. Data were separately evaluated by two blinded groups: metabolic (SUV and MTV), diffusion (ADC) and perfusion (K trans , V e , k ep and iAUC) maps were obtained by positioning regions of interest (ROIs). Tumoral local extension assessed on PET/MRI was compared to endoscopic findings. A good inter-observer agreement was found in anatomical location and local extension of PET/MRI lesions (Cohen's kappa 0.9). PET/CT SUV measures highly correlate with ones derived by PET/MRI (e.g., p=0.96 for measures on VOI). Significant correlations among metabolic, diffusion and perfusion parameters have been detected. PET/MRI had a relevant clinical impact, confirming endoscopic findings (6 cases), helping treatment planning (9 cases), and modifying endoscopic primary staging (1 case). PET/MRI is useful for primary staging of laryngeal cancer, allowing simultaneous collection of metabolic and functional data and conditioning the therapeutic strategies. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Clinical PET application

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Moo; Hong, Song W.; Choi, Chang W.; Yang, Seong Dae [Korea Cancer Center Hospital, Seoul (Korea)

    1997-12-01

    PET gives various methabolic images, and is very important, new diagnostic modality in clinical oncology. In Korea Cancer Center Hospital, PET is installed as a research tool of long-mid-term atomic research project. For the efficient use of PET for clinical and research projects, income from the patients should be managed to get the raw material, equipment, manpower, and also for the clinical PET research. 1. Support the clinical application of PET in oncology. 2. Budgetary management of income, costs for raw material, equipment, manpower, and the clinical PET research project. In this year, 250 cases of PET images were obtained, which resulted total income of 180,000,000 won. 50,000,000 won was deposited for the 1998 PET clinical research. Second year PET clinical research should be managed under unified project. Increased demand for {sup 18}FDG in and outside KCCH need more than 2 times production of {sup 18}FDG in a day purchase of HPLC pump and {sup 68}Ga pin source which was delayed due to economic crisis, should be done early in 1998. (author). 2 figs., 3 tabs.

  5. Imaging with PET system

    International Nuclear Information System (INIS)

    Das, B.K.; Noreen Norfaraheen Lee Abdullah

    2012-01-01

    PET deals with biochemistry and metabolic changes that occur at molecular level. Hence, PET differs fundamentally from other imaging modalities. CT imaging is based on tissue density, whereas MRI conveys anatomic information based on proton density and proton relaxation dynamics. CT and MRI are useful in clinical diagnosis only when disease process has caused significant anatomic alterations. However, in most disease conditions chemical changes precede anatomic changes, that can be detected by PET technology. Thus, PET can provide earliest and unique information about ongoing disease process long before anatomic or structural changes take place. There is no other modality available at present that can replace PET technology. Although PET produces cross-sectional images like that obtained in MRI or CT, they represent circulation, function and metabolism, and not anatomic structure. PET is extremely sensitive measuring quantitatively concentration of tracers in nano to pico-molar range. Thus, PET enables merger of biochemistry and biology in medicine giving birth to molecular medicine that focuses on identifying the molecular errors of disease leading to developing molecular corrections including gene therapy. Molecular imaging with PET has been playing a role in examining the biological nature of a disease condition and its characterization to guide selection and evaluation of treatment. (author)

  6. A survey of PET activity in Germany during 1999

    International Nuclear Information System (INIS)

    Brix, Gunnar; Nosske, Dietmar; Minkov, Vladimir; Glatting, Gerhard; Reske, Sven N.

    2002-01-01

    Positron emission tomography (PET) is the most powerful molecular imaging technique currently available for clinical use. The aim of this study was to provide public health information on PET procedures carried out in Germany - a country with a very high number of PET installations. To this end, all facilities that in 1999 were running at least one dedicated PET system were contacted and requested to provide information in a questionnaire on the radiopharmaceuticals applied, the total number and age distribution of patients and volunteers examined, the main diagnostic applications and the range of administered activities. Based on the information provided by 48 of the 60 PET facilities in Germany, an annual frequency of about 0.34 PET procedures per 1,000 inhabitants was estimated, associated with an annual per capita effective dose of about 1.9 μSv. Averaged over all PET procedures, the mean effective dose to patients was 5.6 mSv. The age distribution of patients and volunteers was skewed markedly towards higher ages; only a very small fraction ( 18 F]fluoro-2-deoxy-D-glucose (FDG), which was utilised in more than 84% of all PET procedures. For this tracer, the median value for activities applied for examinations in the three-dimensional (3D) acquisition mode was only half of that used for two-dimensional (2D) measurements. Based on a statistical analysis of the distribution of mean FDG activities administered to patients in the 48 PET facilities who responded to our inquiry, diagnostic reference levels of 370 and 200 MBq are proposed for the 2D and the 3D mode, respectively. (orig.)

  7. Attenuation correction for the HRRT PET-scanner using transmission scatter correction and total variation regularization

    DEFF Research Database (Denmark)

    Keller, Sune H; Svarer, Claus; Sibomana, Merence

    2013-01-01

    scatter correction in the μ-map reconstruction and total variation filtering to the transmission processing. Results: Comparing MAP-TR and the new TXTV with gold standard CT-based attenuation correction, we found that TXTV has less bias as compared to MAP-TR. We also compared images acquired at the HRRT......In the standard software for the Siemens high-resolution research tomograph (HRRT) positron emission tomography (PET) scanner the most commonly used segmentation in the μ -map reconstruction for human brain scans is maximum a posteriori for transmission (MAP-TR). Bias in the lower cerebellum...

  8. PET-CT in the evaluation of metastatic breast cancer

    International Nuclear Information System (INIS)

    Sullivan, A.M.; Fulham, M.J.

    2005-01-01

    A 44-year-old woman underwent two PET-CT scans for the evaluation of metastatic breast cancer. A radical left mastectomy with axillary dissection (1 of 43 nodes positive) followed by chemotherapy, was performed in 1998. She represented in October 2003 with a left supraclavicular fossa mass. This was confirmed to be recurrent breast cancer on FNAB. She was considered for a radical neck dissection and the surgeon requested a PET scan. Other imaging at this time included a normal bone scan and CT brain. CT neck/chest/abdomen/pelvis showed soft tissue thickening in the left lower neck. The PET-CT scan showed multiple glucose avid lesions in the sternum, mediastinum and neck lymph nodes as well as a small lesion in the proximal left femur consistent with extensive metastatic disease. Surgery was cancelled and Femara chemotherapy commenced. Femara was stopped in March 2004 and the patient began alternative therapies. In October 2004 she presented to her surgeon with new back and chest pain. CT of the neck/chest/abdomen/pelvis showed a soft tissue mass in the upper sternum and a lymph node at the base of the neck highly suspicious for metastatic disease. There were also 2 suspicious lung nodules and a lesion in the proximal left femur reported as an osteoid osteoma. Wholebody PET-CT scans were performed on a Siemens LSO Biograph, 60mins after the injection of 350Mbq of Fl 8-Fag, with arms at the patient's side and head in the field-of-view. On both occasions the patient had to pay for the scan. On the 2004 PET-CT scan, the CT brain revealed multiple hyperdense lesions consistent with hemorrhagic metastases. In addition, there were innumerable glucose avid foci involving viscera, nodes and skeleton consistent with disseminated disease. Our case illustrates: (i) the value of PET in the management of metastatic breast cancer; (ii) the improved accuracy of PET-CT in delineating sites of disease; (iii) the issues of head movement in PET-CT and. (iv) the problem with lack of

  9. Commercial Grade Item (CGI) dedication - on complex electronic equipment

    International Nuclear Information System (INIS)

    Sohn, Kwang Young; Kim, Joong Han; Koo, In Soo; Lee, Sang Yong

    2008-01-01

    In future more complicated IT-based hardware and software is supposed to used in the safety-grade systems in nuclear power plants. Also there are the efforts to establish the criteria for CGI dedications in NRC and CEC dedication in other standard organizations. The highly complicated components, i.e. CEC should be dedication plans. Thus work to be done in later is to prepare the strategies, plans, guide and procedures that is more specific for CEC dedication

  10. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

    OpenAIRE

    Mustafa Demir; Türkay Toklu; Mohammad Abuqbeitah; Hüseyin Çetin; H. Sezer Sezgin; Nami Yeyin; Kerim Sönmezoğlu

    2018-01-01

    Objective: The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. Methods: According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated...

  11. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

    OpenAIRE

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H. Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-01-01

    Objective: The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. Methods: According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated asp...

  12. A dedicated fund supports technological innovation

    CERN Document Server

    Katarina Anthony

    2010-01-01

    The Knowledge and Technology Transfer (KTT) Group is calling on CERN Departments to take their technology out of the confines of the laboratory and make it ready for dissemination. For the first time, projects can apply for financial support from the newly established KTT Fund.   Scientific inquiry can lead to unexpected developments for society when researchers apply their expertise for public use. CERN actively encourages this transfer of knowledge and technology and, for the first time, has created a dedicated fund to provide financial support to projects aiming at disseminating their technologies to external audiences. CERN’s technology transfer schemes were formalised in the recent Policy on the Management of Intellectual Property in Technology Transfer, approved in March. Revenues generated by commercial exploitation will be distributed between the members of the team that developed the technology, their Department, and the KTT Fund for reinvestment in further KTT projects. &qu...

  13. Optical Design Using Small Dedicated Computers

    Science.gov (United States)

    Sinclair, Douglas C.

    1980-09-01

    Since the time of the 1975 International Lens Design Conference, we have developed a series of optical design programs for Hewlett-Packard desktop computers. The latest programs in the series, OSLO-25G and OSLO-45G, have most of the capabilities of general-purpose optical design programs, including optimization based on exact ray-trace data. The computational techniques used in the programs are similar to ones used in other programs, but the creative environment experienced by a designer working directly with these small dedicated systems is typically much different from that obtained with shared-computer systems. Some of the differences are due to the psychological factors associated with using a system having zero running cost, while others are due to the design of the program, which emphasizes graphical output and ease of use, as opposed to computational speed.

  14. [18F]FDG PET/MRI vs. PET/CT for whole-body staging in patients with recurrent malignancies of the female pelvis: initial results

    International Nuclear Information System (INIS)

    Beiderwellen, Karsten; Grueneisen, Johannes; Forsting, Michael; Lauenstein, Thomas C.; Umutlu, Lale; Ruhlmann, Verena; Buderath, Paul; Aktas, Bahriye; Heusch, Philipp; Kraff, Oliver

    2015-01-01

    To evaluate the diagnostic potential of PET/MRI with [ 18 F]FDG in recurrent ovarian and cervical cancer in comparison to PET/CT. A group of 19 patients with suspected recurrence of pelvic malignancies (ovarian cancer, 11 patients; cervical cancer, 8 patients) scheduled for an [ 18 F]FDG PET/CT were subsequently enrolled for a PET/MRI. The scan protocol comprised: (1) a T1-W axial VIBE after contrast agent adminstration, (2) an axial T2-W HASTE, (3) a coronal TIRM, (4) an axial DWI, and dedicated MR sequences of the female pelvis including (5) a T1-W VIBE before contrast agent adminstration, (6) a sagittal T2-W TSE, and (7) a sagittal T1-W dynamic VIBE. The datasets (PET/CT, PET/MRI) were rated separately by two readers regarding lesion count, lesion localization, lesion conspicuity (four-point scale), lesion characterization (benign/malignant/indeterminate) and diagnostic confidence (three-point scale). All available data (histology, prior examinations, PET/CT, PET/MRI, follow-up examinations) served as standard of reference. Median values were compared using the Wilcoxon rank sum test. Metastatic lesions were present in 16 of the 19 patients. A total of 78 lesions (malignant, 58; benign, 20) were described. Both PET/CT and PET/MRI allowed correct identification of all malignant lesions and provided equivalent conspicuity (3.86 ± 0.35 for PET/CT, 3.91 ± 0.28 for PET/MRI; p > 0.05). Diagnostic confidence was significantly higher for PET/MRI in malignant (p < 0.01) and benign lesions (p < 0.05). Both PET/CT and PET/MRI offer an equivalently high diagnostic value for recurrent pelvic malignancies. PET/MRI offers higher diagnostic confidence in the discrimination of benign and malignant lesions. Considering the reduced radiation dose and superior lesion discrimination, PET/MRI may serve as a powerful alternative to PET/CT in the future. (orig.)

  15. [{sup 18}F]FDG PET/MRI vs. PET/CT for whole-body staging in patients with recurrent malignancies of the female pelvis: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Beiderwellen, Karsten; Grueneisen, Johannes; Forsting, Michael; Lauenstein, Thomas C.; Umutlu, Lale [University Hospital Essen, University of Duisburg-Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Ruhlmann, Verena [University Hospital Essen, University of Duisburg-Essen, Clinic for Nuclear Medicine, Essen (Germany); Buderath, Paul; Aktas, Bahriye [University Hospital Essen, University of Duisburg-Essen, Clinic for Obstetrics and Gynecology, Essen (Germany); Heusch, Philipp [University of Dusseldorf, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Kraff, Oliver [University of Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany)

    2015-01-15

    To evaluate the diagnostic potential of PET/MRI with [{sup 18}F]FDG in recurrent ovarian and cervical cancer in comparison to PET/CT. A group of 19 patients with suspected recurrence of pelvic malignancies (ovarian cancer, 11 patients; cervical cancer, 8 patients) scheduled for an [{sup 18}F]FDG PET/CT were subsequently enrolled for a PET/MRI. The scan protocol comprised: (1) a T1-W axial VIBE after contrast agent adminstration, (2) an axial T2-W HASTE, (3) a coronal TIRM, (4) an axial DWI, and dedicated MR sequences of the female pelvis including (5) a T1-W VIBE before contrast agent adminstration, (6) a sagittal T2-W TSE, and (7) a sagittal T1-W dynamic VIBE. The datasets (PET/CT, PET/MRI) were rated separately by two readers regarding lesion count, lesion localization, lesion conspicuity (four-point scale), lesion characterization (benign/malignant/indeterminate) and diagnostic confidence (three-point scale). All available data (histology, prior examinations, PET/CT, PET/MRI, follow-up examinations) served as standard of reference. Median values were compared using the Wilcoxon rank sum test. Metastatic lesions were present in 16 of the 19 patients. A total of 78 lesions (malignant, 58; benign, 20) were described. Both PET/CT and PET/MRI allowed correct identification of all malignant lesions and provided equivalent conspicuity (3.86 ± 0.35 for PET/CT, 3.91 ± 0.28 for PET/MRI; p > 0.05). Diagnostic confidence was significantly higher for PET/MRI in malignant (p < 0.01) and benign lesions (p < 0.05). Both PET/CT and PET/MRI offer an equivalently high diagnostic value for recurrent pelvic malignancies. PET/MRI offers higher diagnostic confidence in the discrimination of benign and malignant lesions. Considering the reduced radiation dose and superior lesion discrimination, PET/MRI may serve as a powerful alternative to PET/CT in the future. (orig.)

  16. 47 CFR 69.125 - Dedicated signalling transport.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Dedicated signalling transport. 69.125 Section... (CONTINUED) ACCESS CHARGES Computation of Charges § 69.125 Dedicated signalling transport. (a) Dedicated signalling transport shall consist of two elements, a signalling link charge and a signalling transfer point...

  17. Fusion of PET and MRI for Hybrid Imaging

    Science.gov (United States)

    Cho, Zang-Hee; Son, Young-Don; Kim, Young-Bo; Yoo, Seung-Schik

    Recently, the development of the fusion PET-MRI system has been actively studied to meet the increasing demand for integrated molecular and anatomical imaging. MRI can provide detailed anatomical information on the brain, such as the locations of gray and white matter, blood vessels, axonal tracts with high resolution, while PET can measure molecular and genetic information, such as glucose metabolism, neurotransmitter-neuroreceptor binding and affinity, protein-protein interactions, and gene trafficking among biological tissues. State-of-the-art MRI systems, such as the 7.0 T whole-body MRI, now can visualize super-fine structures including neuronal bundles in the pons, fine blood vessels (such as lenticulostriate arteries) without invasive contrast agents, in vivo hippocampal substructures, and substantia nigra with excellent image contrast. High-resolution PET, known as High-Resolution Research Tomograph (HRRT), is a brain-dedicated system capable of imaging minute changes of chemicals, such as neurotransmitters and -receptors, with high spatial resolution and sensitivity. The synergistic power of the two, i.e., ultra high-resolution anatomical information offered by a 7.0 T MRI system combined with the high-sensitivity molecular information offered by HRRT-PET, will significantly elevate the level of our current understanding of the human brain, one of the most delicate, complex, and mysterious biological organs. This chapter introduces MRI, PET, and PET-MRI fusion system, and its algorithms are discussed in detail.

  18. Birds Kept as Pets

    Science.gov (United States)

    ... your pet’s health Visit a veterinarian who has experience with pet birds for routine check-ups to keep your bird healthy and prevent infectious diseases. If your bird becomes sick or dies within a month after purchase or adoption: Contact your veterinarian. Inform the pet ...

  19. Model PET Scan Activity

    Science.gov (United States)

    Strunk, Amber; Gazdovich, Jennifer; Redouté, Oriane; Reverte, Juan Manuel; Shelley, Samantha; Todorova, Vesela

    2018-05-01

    This paper provides a brief introduction to antimatter and how it, along with other modern physics topics, is utilized in positron emission tomography (PET) scans. It further describes a hands-on activity for students to help them gain an understanding of how PET scans assist in detecting cancer. Modern physics topics provide an exciting way to introduce students to current applications of physics.

  20. Design Optimization of a TOF, Breast PET Scanner

    OpenAIRE

    Lee, Eunsin; Werner, Matthew E.; Karp, Joel S.; Surti, Suleman

    2013-01-01

    A dedicated breast positron emission tomography (PET) scanner with limited angle geometry can provide flexibility in detector placement around the patient as well as the ability to combine it with other imaging modalities. A primary challenge of a stationary limited angle scanner is the reduced image quality due to artifacts present in the reconstructed image leading to a loss in quantitative information. Previously it has been shown that using time-of-flight (TOF) information in image recons...

  1. AX-PET: A novel PET concept with G-APD readout

    CERN Document Server

    Heller, M; Casella, C; Chesi, E; De Leo, R; Dissertori, G; Fanti, V; Gillam, J E; Joram, C; Lustermann, W; Nappi, E; Oliver, J F; Pauss, F; Rafecas, M; Rudge, A; Ruotsalainen, U; Schinzel, D; Schneider, T; Seguinot, J; Solevi, P; Stapnes, S; Tuna, U; Weilhammer, P

    2012-01-01

    The AX-PET collaboration has developed a novel concept for high resolution PET imaging to overcome some of the performance limitations of classical PET cameras, in particular the compromise between spatial resolution and sensitivity introduced by the parallax error. The detector consists of an arrangement of long LYSO scintillating crystals axially oriented around the field of view together with arrays of wave length shifter strips orthogonal to the crystals. This matrix allows a precise 3D measurement of the photon interaction point. This is valid both for photoelectric absorption at 511 key and for Compton scattering down to deposited energies of about 100 keV. Crystals and WLS strips are individually read out using Geiger-mode Avalanche Photo Diodes (G-APDs). The sensitivity of such a detector can be adjusted by changing the number of layers and the resolution is defined by the crystal and strip dimensions. Two AX-PET modules were built and fully characterized in dedicated test set-ups at CERN, with point-...

  2. Fluorine-18-Fluorodeoxyglucose PET in the mediastinal nodal staging of bronchogenic carcinoma.

    Energy Technology Data Exchange (ETDEWEB)

    Berlangieri, S.U.; Scott, A.M.; Knight, S.; Pointon, O.; Thomas, D.L.; O``Keefe, G.; Chan, J.G.; Egen, G.F.; Tochon-Danguy, H.J.; Clarke, C.P.; McKay, W.J. [Austin Hospital, Melbourne, VIC (Australia). Centre for Positron Emission Tomography and the Departments of Nuclear Medicine and Thoracic Surgery

    1998-03-01

    Full text: Non-invasive methods of pre-operative staging of non-small cell bronchogenic carcinoma are inaccurate. To determine the clinical role of positron emission tomography (PET) in the mediastinal staging of lung carcinoma, {sup 18}F-fluorodeoxyglucose (FDG) studies were performed in 25 patients with suspected non-small cell bronchogenic carcinoma and correlated with pathology. The patients comprised 20 men and 5 women (mean age 63; range 43-78 y). All patients had proven non-small cell lung carcinoma, except two, one patient with benign inflammatory disease and the other with small cell carcinoma. The FDG PET studies were acquired on a Siemens 951131R body tomography over 2-3 bed positions to include the thorax and mediastinum. The PET images were interpreted for tumour involvement of mediastinal nodes according to the American Thoracic Society classification and scored for confidence of tumour presence on a 5 point scale. The intensity of glucose metabolism was compared to mediastinal blood pool activity and graded on a 4 point scale. FDG PET correctly excluded ipsilateral mediastinal nodal (N2) disease in 16 of 16 patients. Six of nine patients with N2 disease were correctly identified by FDG PET. Of the three patients with N2 nodal involvement not detected by PET, each had single station nodal disease, and in two patients the primary lesions abutted the involved nodal group. A total of 104 nodal stations were sampled or examined at surgery. FDG PET correctly excluded disease in 83/83 (100% specificity) negative nodal stations. FDG PET is a promising non-invasive functional imaging modality for the mediastinal staging of bronchogenic carcinoma.

  3. Dynamic respiratory gated 18FDG-PET of lung tumors - a feasibility study

    International Nuclear Information System (INIS)

    Skjei Knudtsen, Ingerid; Skretting, Arne; Roedal, Jan; Brustugun, Odd Terje; Helland, Aaslaug; Malinen, Eirik

    2011-01-01

    Background. 18 FDG-PET/CT imaging is well established for diagnosis and staging of lung tumors. However, more detailed information regarding the distribution of FDG within the tumor, also as a function of time after injection may be relevant. In this study we explore the feasibility of a combined dynamic and respiratory gated (DR) PET protocol. Material and methods. A DR FDG-PET protocol for a Siemens Biograph 16 PET/CT scanner was set up, allowing data acquisition from the time of FDG injection. Breath-hold (BH) respiratory gating was performed at four intervals over a total acquisition time of 50 minutes. Thus, the PET protocol provides both motion-free images and a spatiotemporal characterization of the glucose distribution in lung tumors. Software tools were developed in-house for tentative tumor segmentation and for extracting standard uptake values (SUVs) voxel by voxel, tumor volumes and SUV gradients in all directions. Results. Four pilot patients have been investigated with the DR PET protocol. The procedure was well tolerated by the patients. The BH images appeared sharper, and SUV max /SUV mean was higher, compared to free breathing (FB) images. Also, SUV gradients in the periphery of the tumor in the BH images were in general greater than or equal to the gradients in the FB PET images. Conclusion. The DR FDG-PET protocol is feasible and the BH images have a superior quality compared to the FB images. The protocol may also provide information of relevance for radiotherapy planning and follow-up. A patient trial is needed for assessing the clinical value of the imaging protocol

  4. Usage of Recycled Pet

    Directory of Open Access Journals (Sweden)

    A. Ebru Tayyar

    2010-01-01

    Full Text Available The increasing industrialization, urbanization and the technological development have caused to increase depletion of the natural resources and environmental pollution's problem. Especially, for the countries which have not enough space recycling of the waste eliminating waste on regular basis or decreasing the amount and volume of waste have provided the important advantages. There are lots of studies and projects to develop both protect resources and prevent environmental pollution. PET bottles are commonly used in beverage industry and can be reused after physical and chemical recycling processes. Usage areas of recycled PET have been developed rapidly. Although recycled PET is used in plastic industry, composite industry also provides usage alternatives of recycled PET. Textile is a suitable sector for recycling of some plastics made of polymers too. In this study, the recycling technologies and applications of waste PET bottles have been investigated and scientific works in this area have been summarized.

  5. Oncology PET imaging

    International Nuclear Information System (INIS)

    Inubushi, Masayuki

    2014-01-01

    At the beginning of this article, likening medical images to 'Where is Waldo?' I indicate the concept of diagnostic process of PET/CT imaging, so that medical physics specialists could understand the role of each imaging modality and infer our distress for image diagnosis. Then, I state the present situation of PET imaging and the basics (e.g. health insurance coverage, clinical significance, principle, protocol, and pitfall) of oncology FDG-PET imaging which accounts for more than 99% of all clinical PET examinations in Japan. Finally, I would like to give a wishful prospect of oncology PET that will expand to be more cancer-specific in order to assess therapeutic effects of emerging molecular targeted drugs targeting the 'hallmarks of cancer'. (author)

  6. Multiparametric evaluation by simultaneous PET-MRI examination in patients with histologically proven laryngeal cancer

    International Nuclear Information System (INIS)

    Cavaliere, Carlo; Romeo, Valeria; Aiello, Marco; Mesolella, Massimo; Iorio, Brigida; Barbuto, Luigi; Cantone, Elena; Nicolai, Emanuele; Covello, Mario

    2017-01-01

    Highlights: • PET/MRI is feasible and useful for primary staging of laryngeal cancer. • PET/MRI simultaneously provides morphological, metabolic and functional parameters of tumoral laryngeal lesions. • PET/MRI allows an appropriate tumoral staging in terms of lesion extension with significant impact on therapeutic strategies. - Abstract: Objectives: To evaluate the relationship between metabolic 18Fluoro-Deoxyglucose-Positron Emission Tomography (18FDG/PET) and morpho-functional parameters derived by Magnetic Resonance Imaging (MRI) in patients with histologically proven laryngeal cancer. To assess the clinical impact of PET/MRI examination on patient’s staging and treatment planning. Methods: 16 patients with histologically proven laryngeal cancer were enrolled and underwent whole body PET/CT followed by a dedicated PET/MRI of the head/neck region. Data were separately evaluated by two blinded groups: metabolic (SUV and MTV), diffusion (ADC) and perfusion (K trans , V e , k ep and iAUC) maps were obtained by positioning regions of interest (ROIs). Tumoral local extension assessed on PET/MRI was compared to endoscopic findings. Results: A good inter-observer agreement was found in anatomical location and local extension of PET/MRI lesions (Cohen’s kappa 0.9). PET/CT SUV measures highly correlate with ones derived by PET/MRI (e.g., p = 0.96 for measures on VOI). Significant correlations among metabolic, diffusion and perfusion parameters have been detected. PET/MRI had a relevant clinical impact, confirming endoscopic findings (6 cases), helping treatment planning (9 cases), and modifying endoscopic primary staging (1 case). Conclusions: PET/MRI is useful for primary staging of laryngeal cancer, allowing simultaneous collection of metabolic and functional data and conditioning the therapeutic strategies.

  7. Multiparametric evaluation by simultaneous PET-MRI examination in patients with histologically proven laryngeal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Cavaliere, Carlo [IRCCS SDN, Via E. Gianturco, 113-80143, Naples (Italy); Romeo, Valeria, E-mail: valeria.romeo@unina.it [Department of Advanced Biomedical Sciences, Federico II University, Naples (Italy); Aiello, Marco [IRCCS SDN, Via E. Gianturco, 113-80143, Naples (Italy); Mesolella, Massimo; Iorio, Brigida [Department of Neuroscience, Reproductive and Odontostomatologic Science, ENT Section, Federico II University, Naples (Italy); Barbuto, Luigi [Department of Advanced Biomedical Sciences, Federico II University, Naples (Italy); Cantone, Elena [Department of Neuroscience, Reproductive and Odontostomatologic Science, ENT Section, Federico II University, Naples (Italy); Nicolai, Emanuele; Covello, Mario [IRCCS SDN, Via E. Gianturco, 113-80143, Naples (Italy)

    2017-03-15

    Highlights: • PET/MRI is feasible and useful for primary staging of laryngeal cancer. • PET/MRI simultaneously provides morphological, metabolic and functional parameters of tumoral laryngeal lesions. • PET/MRI allows an appropriate tumoral staging in terms of lesion extension with significant impact on therapeutic strategies. - Abstract: Objectives: To evaluate the relationship between metabolic 18Fluoro-Deoxyglucose-Positron Emission Tomography (18FDG/PET) and morpho-functional parameters derived by Magnetic Resonance Imaging (MRI) in patients with histologically proven laryngeal cancer. To assess the clinical impact of PET/MRI examination on patient’s staging and treatment planning. Methods: 16 patients with histologically proven laryngeal cancer were enrolled and underwent whole body PET/CT followed by a dedicated PET/MRI of the head/neck region. Data were separately evaluated by two blinded groups: metabolic (SUV and MTV), diffusion (ADC) and perfusion (K{sub trans}, V{sub e}, k{sub ep} and iAUC) maps were obtained by positioning regions of interest (ROIs). Tumoral local extension assessed on PET/MRI was compared to endoscopic findings. Results: A good inter-observer agreement was found in anatomical location and local extension of PET/MRI lesions (Cohen’s kappa 0.9). PET/CT SUV measures highly correlate with ones derived by PET/MRI (e.g., p = 0.96 for measures on VOI). Significant correlations among metabolic, diffusion and perfusion parameters have been detected. PET/MRI had a relevant clinical impact, confirming endoscopic findings (6 cases), helping treatment planning (9 cases), and modifying endoscopic primary staging (1 case). Conclusions: PET/MRI is useful for primary staging of laryngeal cancer, allowing simultaneous collection of metabolic and functional data and conditioning the therapeutic strategies.

  8. Development of baby cyclotron for PET in Korea

    International Nuclear Information System (INIS)

    Chai, J.S.; Kim, Y.S.; Hu, J.Y.; Shin, Y.C.; Yoon, M.H.

    2001-01-01

    Development of a 13 MeV cyclotron for Positron Emission Tomography (PET) has been in progress since April 1999 at the Korea Cancer Center Hospital (KCCH). The study has been carried out in a joint collaboration between KCCH and the Pohang University of Science and Technology (POSTECH). Increasing desire for an uninterrupted, reliable and timely supply of the isotopes to customers has prompted obtaining a dedicated 5-13 MeV cyclotron for PET applications and pursuing the purchase of another 30MeV medical cyclotron in the very near future. A decision has been made to design the PET cyclotron in Korea. This will not only ease the problems associated with maintenance during operation but also keep the door open for continuous upgrading of the machine in the future

  9. The effect of different adaptation strengths on image quality and radiation dose using Siemens care dose 4D

    International Nuclear Information System (INIS)

    Soederberg, M.; Gunnarsson, M.

    2010-01-01

    The purpose of this study was to evaluate the effect of different choices of adaptation strengths on image quality and radiation exposure to the patient with Siemens automatic exposure control system called CARE Dose 4D. An anthropomorphic chest phantom was used to simulate the patient and computed tomography scans were performed with a Siemens SOMATOM Sensation 16 and 64. Owing to adaptation strengths, a considerable reduction (26.6-51.5 % and 27.5-49.5% for Sensation 16 and Sensation 64, respectively) in the radiation dose was found when compared with using a fixed tube current. There was a substantial difference in the image quality (image noise) between the adaptation strengths. Independent of selected adaptation strengths, the level of image noise throughout the chest phantom increased when CARE Dose 4D was used (p < 0.0001). We conclude that the adaptation strengths can be used to obtain user-specified modifications to image quality or radiation exposure to the patient. (authors)

  10. 18F-FDG PET in children with lymphomas

    International Nuclear Information System (INIS)

    Depas, Gisele; Barsy, Caroline De; Foidart, Jacqueline; Rigo, Pierre; Hustinx, Roland; Jerusalem, Guy; Hoyoux, Claire; Dresse, Marie-Francoise; Fassotte, Marie-France; Paquet, Nancy

    2005-01-01

    The aim of this study was to retrospectively evaluate the performance of positron emission tomography (PET) with 18 F-fluorodeoxyglucose ( 18 F-FDG) in children with lymphomas, at various stages of their disease. Twenty-eight children (mean age 12.5 years, 14 girls, 14 boys) with Hodgkin's disease (HD, n=17) or non-Hodgkin's lymphoma (NHL, n=11) were evaluated. Patients were investigated at initial staging (n=19), early in the course of treatment (n=19), at the end of treatment (n=16) and during long-term follow-up (n=19). A total of 113 whole-body PET studies were performed on dedicated scanners. PET results were compared with the results of conventional methods (CMs) such as physical examination, laboratory studies, chest X-rays, computed tomography, magnetic resonance imaging, ultrasonography and bone scan when available. At initial evaluation (group 1), PET changed the disease stage and treatment in 10.5% of the cases. In early evaluation of the response to treatment (group 2), PET failed to predict two relapses and one incomplete response to treatment. In this group, however, PET did not show any false positive results. There were only 4/75 false positive results for PET among patients studied at the end of treatment (group 3, specificity 94%) or during the systematic follow-up (group 4, specificity 95%), as compared with 27/75 for CMs (specificity 54% and 66%, respectively). 18 F-FDG-PET is a useful tool for evaluating children with lymphomas. Large prospective studies are needed to appreciate its real impact on patient management. (orig.)

  11. Cost effective nuclear commercial grade dedication

    International Nuclear Information System (INIS)

    Maletz, J.J.; Marston, M.J.

    1991-01-01

    This paper describes a new computerized database method to create/edit/view specification technical data sheets (mini-specifications) for procurement of spare parts for nuclear facility maintenance and to develop information that could support possible future facility life extension efforts. This method may reduce cost when compared with current manual methods. The use of standardized technical data sheets (mini-specifications) for items of the same category improves efficiency. This method can be used for a variety of tasks, including: Nuclear safety-related procurement; Non-safety related procurement; Commercial grade item procurement/dedication; Evaluation of replacement items. This program will assist the nuclear facility in upgrading its procurement activities consistent with the recent NUMARC Procurement Initiative. Proper utilization of the program will assist the user in assuring that the procured items are correct for the applications, provide data to assist in detecting fraudulent materials, minimize human error in withdrawing database information, improve data retrievability, improve traceability, and reduce long-term procurement costs

  12. Virtual Machine Scheduling in Dedicated Computing Clusters

    CERN Document Server

    Boettger, Stefan; Zicari, V Roberto

    2014-01-08

    Time-critical applications process a continuous stream of input data and have to meet specific timing constraints. A common approach to ensure that such an application satisfies its constraints is over-provisioning: The application is deployed in a dedicated cluster environment with enough processing power to achieve the target performance for every specified data input rate. This approach comes with a drawback: At times of decreased data input rates, the cluster resources are not fully utilized. A typical use case is the HLT-Chain application that processes physics data at runtime of the ALICE experiment at CERN. From a perspective of cost and efficiency it is desirable to exploit temporarily unused cluster resources. Existing approaches aim for that goal by running additional applications. These approaches, however, a) lack in flexibility to dynamically grant the time-critical application the resources it needs, b) are insufficient for isolating the time-critical application from harmful side-effects i...

  13. A subjective scheduler for subjective dedicated networks

    Science.gov (United States)

    Suherman; Fakhrizal, Said Reza; Al-Akaidi, Marwan

    2017-09-01

    Multiple access technique is one of important techniques within medium access layer in TCP/IP protocol stack. Each network technology implements the selected access method. Priority can be implemented in those methods to differentiate services. Some internet networks are dedicated for specific purpose. Education browsing or tutorial video accesses are preferred in a library hotspot, while entertainment and sport contents could be subjects of limitation. Current solution may use IP address filter or access list. This paper proposes subjective properties of users or applications are used for priority determination in multiple access techniques. The NS-2 simulator is employed to evaluate the method. A video surveillance network using WiMAX is chosen as the object. Subjective priority is implemented on WiMAX scheduler based on traffic properties. Three different traffic sources from monitoring video: palace, park, and market are evaluated. The proposed subjective scheduler prioritizes palace monitoring video that results better quality, xx dB than the later monitoring spots.

  14. Conception of comics dedicated to optics learning

    Science.gov (United States)

    Machemy, Jacques; Bousquet, Bruno

    2015-10-01

    Optics' teaching is commonly based on the use of lessons including several mathematical tools. For example, ray tracing can be described through matrix algebra, and interference and polarization can be supported by the use of complex numbers. Thus, the numerous mathematical descriptions included in the optics' lessons represent a real difficulty for students having insufficient skills in mathematics. Moreover, despite of very impressive optical effects one can observe in real life, e.g. rainbows, their description in optics' courses is often considered as too academic and boring, and finally not really exciting. In this context, we have invented a new type of comics dedicated to optics' learning. Based on a dialogue between two imaginary characters, one considered as the young student and the other one as the old teacher, we have chosen to reduce the role of mathematics and to mix realistic and unrealistic elements in the drawing to complete the explanations faster. Starting from reflection and refraction, the Snell's laws then allow for describing natural phenomena such as mirage and rainbow as well as technical points such as light propagation into an optical fiber and the measurement of the refraction index. The first volume presented here will be evaluated during the fall semester 2015 in different high schools and at university through a linked survey and the students will also get access to an online version while the following parts are in preparation.

  15. Feasibility and acceptance of simultaneous amyloid PET/MRI

    International Nuclear Information System (INIS)

    Schuetz, Lisa; Tiepolt, Solveig; Werner, Peter; Jochimsen, Thies; Rullmann, Michael; Sattler, Bernhard; Patt, Marianne; Barthel, Henryk; Lobsien, Donald; Fritzsch, Dominik; Hoffmann, Karl-Titus; Schroeter, Matthias L.; Villringer, Arno; Berrouschot, Joerg; Saur, Dorothee; Classen, Joseph; Hesse, Swen; Sabri, Osama; Gertz, Hermann-Josef

    2016-01-01

    Established Alzheimer's disease (AD) biomarker concepts classify into amyloid pathology and neuronal injury biomarkers, while recent alternative concepts classify into diagnostic and progression AD biomarkers. However, combined amyloid positron emission tomography/magnetic resonance imaging (PET/MRI) offers the chance to obtain both biomarker category read-outs within one imaging session, with increased patient as well as referrer convenience. The aim of this pilot study was to investigate this matter for the first time. 100 subjects (age 70 ± 10 yrs, 46 female), n = 51 with clinically defined mild cognitive impairment (MCI), n = 44 with possible/probable AD dementia, and n = 5 with frontotemporal lobe degeneration, underwent simultaneous [ 18 F]florbetaben or [ 11 C]PIB PET/MRI (3 Tesla Siemens mMR). Brain amyloid load, mesial temporal lobe atrophy (MTLA) by means of the Scheltens scale, and other morphological brain pathologies were scored by respective experts. The patients/caregivers as well as the referrers were asked to assess on a five-point scale the convenience related to the one-stop-shop PET and MRI approach. In three subjects, MRI revealed temporal lobe abnormalities other than MTLA. According to the National Institute on Aging-Alzheimer's Association classification, the combined amyloid-beta PET/MRI evaluation resulted in 31 %, 45 %, and 24 % of the MCI subjects being categorized as ''MCI-unlikely due to AD'', ''MCI due to AD-intermediate likelihood'', and ''MCI due to AD-high likelihood'', respectively. 50 % of the probable AD dementia patients were categorized as ''High level of evidence of AD pathophysiological process'', and 56 % of the possible AD dementia patients as ''Possible AD dementia - with evidence of AD pathophysiological process''. With regard to the International Working Group 2 classification, 36 subjects had both positive

  16. Markerless PET motion correction: tracking in narrow gantries through optical fibers

    DEFF Research Database (Denmark)

    Jensen, Rasmus Ramsbøl; Olesen, Oline Vinter; Benjaminsen, Claus

    2015-01-01

    be accurate while only adding minimal complexity to the workflow. We present: Tracoline 2.0, a surface scanner prototype, which allows for markerless tracking in the clinic. The system uses structured light through optical fibre bundles, which easily fit in narrow gantries. The optical fibres also makes...... the system compatible with magnetic resonance (MR) imaging since all the electronics are moved away from the scanner. We demonstrate the system in a positron emission tomography (PET) study using the Siemens high resolution research tomography (HRRT). With two Ge/Ga-68 line sources fitted in a mannequin head...... for rotations up to ±25º. Based on the tracking results the PET frames were also successfully corrected for motion by aligning 10 s frames without motion for the stepwise experiment and aligning 1 s frames for the experiment with continuous motion. We have demonstrated and evaluated a system for markerless...

  17. Initial clinical results of simultaneous {sup 18}F-FDG PET/MRI in comparison to {sup 18}F-FDG PET/CT in patients with head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kubiessa, K.; Gawlitza, M.; Kuehn, A.; Fuchs, J.; Kahn, T.; Stumpp, P. [University Hospital of Leipzig, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Purz, S.; Steinhoff, K.G.; Sabri, O.; Kluge, R. [University Hospital of Leipzig, Department of Nuclear Medicine, Leipzig (Germany); Boehm, A. [University Hospital of Leipzig, ENT Department, Leipzig (Germany)

    2014-04-15

    The aim of this study was to evaluate the diagnostic capability of simultaneous {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/MRI compared to {sup 18}F-FDG PET/CT as well as their single components in head and neck cancer patients. In a prospective study 17 patients underwent {sup 18}F-FDG PET/CT for staging or follow-up and an additional {sup 18}F-FDG PET/MRI scan with whole-body imaging and dedicated examination of the neck. MRI, CT and PET images as well as PET/MRI and PET/CT examinations were evaluated independently and in a blinded fashion by two reader groups. Results were compared with the reference standard (final diagnosis determined in consensus using all available data including histology and follow-up). Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. A total of 23 malignant tumours were found with the reference standard. PET/CT showed a sensitivity of 82.7 %, a specificity of 87.3 %, a PPV of 73.2 % and a NPV of 92.4 %. Corresponding values for PET/MRI were 80.5, 88.2, 75.6 and 92.5 %. No statistically significant difference in diagnostic capability could be found between PET/CT and PET/MRI. Evaluation of the PET part from PET/CT revealed highest sensitivity of 95.7 %, and MRI showed best specificity of 96.4 %. There was a high inter-rater agreement in all modalities (Cohen's kappa 0.61-0.82). PET/MRI of patients with head and neck cancer yielded good diagnostic capability, similar to PET/CT. Further studies on larger cohorts to prove these first results seem justified. (orig.)

  18. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.

    Science.gov (United States)

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-02-01

    The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  19. Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Paulus, Daniel H.; Thorwath, Daniela; Schmidt, Holger; Quick, Harald H.

    2014-01-01

    Purpose: Multimodality imaging has become an important adjunct of state-of-the-art radiation therapy (RT) treatment planning. Recently, simultaneous PET/MR hybrid imaging has become clinically available and may also contribute to target volume delineation and biological individualization in RT planning. For integration of PET/MR hybrid imaging into RT treatment planning, compatible dedicated RT devices are required for accurate patient positioning. In this study, prototype RT positioning devices intended for PET/MR hybrid imaging are introduced and tested toward PET/MR compatibility and image quality. Methods: A prototype flat RT table overlay and two radiofrequency (RF) coil holders that each fix one flexible body matrix RF coil for RT head/neck imaging have been evaluated within this study. MR image quality with the RT head setup was compared to the actual PET/MR setup with a dedicated head RF coil. PET photon attenuation and CT-based attenuation correction (AC) of the hardware components has been quantitatively evaluated by phantom scans. Clinical application of the new RT setup in PET/MR imaging was evaluated in anin vivo study. Results: The RT table overlay and RF coil holders are fully PET/MR compatible. MR phantom and volunteer imaging with the RT head setup revealed high image quality, comparable to images acquired with the dedicated PET/MR head RF coil, albeit with 25% reduced SNR. Repositioning accuracy of the RF coil holders was below 1 mm. PET photon attenuation of the RT table overlay was calculated to be 3.8% and 13.8% for the RF coil holders. With CT-based AC of the devices, the underestimation error was reduced to 0.6% and 0.8%, respectively. Comparable results were found within the patient study. Conclusions: The newly designed RT devices for hybrid PET/MR imaging are PET and MR compatible. The mechanically rigid design and the reproducible positioning allow for straightforward CT-based AC. The systematic evaluation within this study provides the

  20. Hybrid PET/MRI insert: B0 field optimization by applying active and passive shimming on PET detector level

    Energy Technology Data Exchange (ETDEWEB)

    Wehner, Jakob [Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen (Germany); Weissler, Bjoern [Philips Research Europe, Aachen (Germany); Schulz, Volkmar [Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen (Germany); Philips Research Europe, Aachen (Germany)

    2014-07-29

    Combining PET and MRI into a hybrid device is challenging since both systems might influence each other. A typical interference problem of such a combined device is the distortion of the MRI’s B{sub 0} field distribution due to the material brought inside the MRI’s FOV which is in particular challenging for small-bore PET-systems. High field homogeneity is needed for a good MRI acquisition in general as well as in certain applications. Typically, active shimming using dedicated coils is applied to improve the field homogeneity. However, these techniques are limited especially for localized distortion profiles with higher-order characteristics caused by PET/MRI inserts. As a consequence, we are exploring the potential application of shimming on PET detector level (for the Hyperion-II{sup D} PET/MRI insert), meaning that the distortion profile caused by PET modules is compensated using additional magnetic materials (passive shimming) and DC coils (active shimming). To explore the technique, B{sub 0} field measurements have been performed using a whole-body phantom in combination with the MRI body coil. An FFE sequence was used to measure distortion maps of DC loops and small magnetic objects (capacitors, ferrites). These distortion maps served as input for a software framework which has been written to perform the field optimization. The implementation was verified by measurements and fits were performed to extract characteristic parameters of the tested objects. Finally, the implemented software framework was used to homogenize a measured distortion map produced by a single PET module by superimposing distortion corrections from additional simulated materials. The resulting superimposed distortion map showed a significantly improved B{sub 0} field map quality (reduced spectral width and improved homogeneity). The simulated susceptibility distribution will be applied on PET module level and tested in experiments. Results and details about this study will be

  1. Multi institutional quantitative phantom study of yttrium-90 PET in PET/MRI: the MR-QUEST study.

    Science.gov (United States)

    Maughan, Nichole M; Eldib, Mootaz; Faul, David; Conti, Maurizio; Elschot, Mattijs; Knešaurek, Karin; Leek, Francesca; Townsend, David; DiFilippo, Frank P; Jackson, Kimberly; Nekolla, Stephan G; Lukas, Mathias; Tapner, Michael; Parikh, Parag J; Laforest, Richard

    2018-04-04

    Yttrium-90 ( 90 Y) radioembolization involves the intra-arterial delivery of radioactive microspheres to treat hepatic malignancies. Though this therapy involves careful pre-treatment planning and imaging, little is known about the precise location of the microspheres once they are administered. Recently, there has been growing interest post-radioembolization imaging using positron-emission tomography (PET) for quantitative dosimetry and identifying lesions that may benefit from additional salvage therapy. In this study, we aim to measure the inter-center variability of 90 Y PET measurements as measured on PET/MRI in preparation for a multi-institutional prospective phase I/II clinical trial. Eight institutions participated in this study and followed a standardized phantom filling and imaging protocol. The NEMA NU2-2012 body phantom was filled with 3 GBq of 90 Y chloride solution. The phantom was imaged for 30 min in listmode on a Siemens Biograph mMR non-TOF PET/MRI scanner at five time points across 10 days (0.3-3.0 GBq). Raw PET data were sent to a central site for image reconstruction and data analysis. Images were reconstructed with optimal parameters determined from a previous study. Volumes of interest (VOIs) matching the known sphere diameters were drawn on the vendor-provided attenuation map and propagated to the PET images. Recovery coefficients (RCs) and coefficient of variation of the RCs (COV) were calculated from these VOIs for each sphere size and activity level. Mean RCs ranged from 14.5 to 75.4%, with the lowest mean RC coming from the smallest sphere (10 mm) on the last day of imaging (0.16 MBq/ml) and the highest mean RC coming from the largest sphere (37 mm) on the first day of imaging (2.16 MBq/ml). The smaller spheres tended to exhibit higher COVs. In contrast, the larger spheres tended to exhibit lower COVs. COVs from the 37 mm sphere were  25%. Post-radioembolization dosimetry of lesions or other VOIs ≥ 22 mm in diameter can

  2. PET/MRI in the Presence of Metal Implants: Completion of the Attenuation Map from PET Emission Data.

    Science.gov (United States)

    Fuin, Niccolo; Pedemonte, Stefano; Catalano, Onofrio A; Izquierdo-Garcia, David; Soricelli, Andrea; Salvatore, Marco; Heberlein, Keith; Hooker, Jacob M; Van Leemput, Koen; Catana, Ciprian

    2017-05-01

    We present a novel technique for accurate whole-body attenuation correction in the presence of metallic endoprosthesis, on integrated non-time-of-flight (non-TOF) PET/MRI scanners. The proposed implant PET-based attenuation map completion (IPAC) method performs a joint reconstruction of radioactivity and attenuation from the emission data to determine the position, shape, and linear attenuation coefficient (LAC) of metallic implants. Methods: The initial estimate of the attenuation map was obtained using the MR Dixon method currently available on the Siemens Biograph mMR scanner. The attenuation coefficients in the area of the MR image subjected to metal susceptibility artifacts are then reconstructed from the PET emission data using the IPAC algorithm. The method was tested on 11 subjects presenting 13 different metallic implants, who underwent CT and PET/MR scans. Relative mean LACs and Dice similarity coefficients were calculated to determine the accuracy of the reconstructed attenuation values and the shape of the metal implant, respectively. The reconstructed PET images were compared with those obtained using the reference CT-based approach and the Dixon-based method. Absolute relative change (aRC) images were generated in each case, and voxel-based analyses were performed. Results: The error in implant LAC estimation, using the proposed IPAC algorithm, was 15.7% ± 7.8%, which was significantly smaller than the Dixon- (100%) and CT- (39%) derived values. A mean Dice similarity coefficient of 73% ± 9% was obtained when comparing the IPAC- with the CT-derived implant shape. The voxel-based analysis of the reconstructed PET images revealed quantification errors (aRC) of 13.2% ± 22.1% for the IPAC- with respect to CT-corrected images. The Dixon-based method performed substantially worse, with a mean aRC of 23.1% ± 38.4%. Conclusion: We have presented a non-TOF emission-based approach for estimating the attenuation map in the presence of metallic implants, to

  3. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Rollo, F.D.; Hines, H.

    2001-01-01

    ADAC Laboratories has two main imaging strengths: PET and Gamma Cameras. PET's three-dimensional imaging of metabolic function is used in oncology, with emerging opportunties in cardiology, genetic mapping and pharmaceuticals research. In oncology, PET imaging can provide comprehensive and accurate staging information which is not available from CT or MRI. In some cases, this information can lead to modification of treatment, for example from an aggressive approach to one of palliation. The SKYLight is the world's first and only gantry-free camera. It is a dual-detector variable angle camera designed for high throughput, with unsurpassed openness and patient access. (orig.)

  4. Initial Experience With Simultaneous 18F-FDG PET/MRI in the Evaluation of Cardiac Sarcoidosis and Myocarditis.

    Science.gov (United States)

    Hanneman, Kate; Kadoch, Michael; Guo, Henry H; Jamali, Mehran; Quon, Andrew; Iagaru, Andrei; Herfkens, Robert

    2017-07-01

    The purpose of this study was to compare combined PET/MRI with PET/CT and cardiac MRI in the evaluation of cardiac sarcoidosis and myocarditis. Ten patients (4 men and 6 women; 56.1 ± 9.6 years old) were prospectively enrolled for evaluation of suspected cardiac sarcoidosis or myocarditis. Written informed consent was obtained. Following administration of 9.9 ± 0.9 mCi F-FDG, patients underwent standard cardiac PET/CT followed by combined PET/MRI using a simultaneous 3-T scanner. Cardiac MRI sequences included ECG-triggered cine SSFP, T2-weighted, and late gadolinium-enhanced imaging. Myocardial involvement was assessed with separate analysis of combined PET/MRI, PET/CT, and cardiac MRI data using dedicated postprocessing software. Estimates of radiation dose were derived from the applied doses of F-FDG and CT protocol parameters. Imaging was acquired with a delay from F-FDG injection of 90.2 ± 27.4 minutes for PET/CT and 207.7 ± 40.3 minutes for PET/MRI. Total scan time for PET/MRI was significantly longer than for PET/CT (81.4 ± 14.8 vs 12.0 minutes, P PET/MRI compared with PET/CT (6.9 ± 0.6 vs 8.2 ± 1.1 mSv, P = 0.007). There was no significant difference in the number of positive cases identified between combined PET/MRI (n = 10 [100%]), PET/CT (n = 6 [60%]), and cardiac MRI (n = 8 [80%]), P = 0.091. Simultaneous cardiac PET/MRI is feasible in the evaluation of cardiac sarcoidosis and myocarditis achieving diagnostic image quality.

  5. Special Issue Dedication to Stephen H. Schneider

    Directory of Open Access Journals (Sweden)

    Paul Baer

    2011-12-01

    Full Text Available It is with both pleasure and sadness that we dedicate this special climate change issue of Portal to the late Dr. Stephen H. Schneider. Steve, as he was known to his friends and colleagues, was as rare a bird as any he sought out in his passion as a birdwatcher. A brilliant climate scientist, author of countless books and papers, path breaking inter-disciplinarian, eminent public communicator, mentor to dozens of young scholars; the list of roles and adulatory adjectives could fill an IPCC special report. Steve would have appreciated this special issue, with its multidisciplinary approach, and its quest for solutions based on analytical scholarship. He understood better than most the inseparability of normative and descriptive concerns, the need for academics and scientists of all kinds to be involved with public processes of communication, policy design and deliberation. While his last book was called “Science as a Contact Sport,” the unspoken title of his career might have been “Science as a Public Service.” He was endlessly testifying, consulting and giving interviews, and encouraged others to learn to do the same. Notwithstanding a battle with lymphoma in the last decade (chronicled in the wonderful book The Patient from Hell, Steve maintained a frenetic level of activity and was still going strong when he was felled by a pulmonary embolism in July of 2010 at age 65. He leaves behind a legacy embodied in his publications, institutions like the IPCC and the journal Climatic Change, and in the hearts and minds of the countless persons he interacted with, mentored, and loved. Exuberant, passionate, full of warmth and good humor, Steve was a mensch among mensches. He will be sorely missed. Paul Baer, with the assistance of Terry Root and Ian McGregor.

  6. Multimodality Registration without a Dedicated Multimodality Scanner

    Directory of Open Access Journals (Sweden)

    Bradley J. Beattie

    2007-03-01

    Full Text Available Multimodality scanners that allow the acquisition of both functional and structural image sets on a single system have recently become available for animal research use. Although the resultant registered functional/structural image sets can greatly enhance the interpretability of the functional data, the cost of multimodality systems can be prohibitive, and they are often limited to two modalities, which generally do not include magnetic resonance imaging. Using a thin plastic wrap to immobilize and fix a mouse or other small animal atop a removable bed, we are able to calculate registrations between all combinations of four different small animal imaging scanners (positron emission tomography, single-photon emission computed tomography, magnetic resonance, and computed tomography [CT] at our disposal, effectively equivalent to a quadruple-modality scanner. A comparison of serially acquired CT images, with intervening acquisitions on other scanners, demonstrates the ability of the proposed procedures to maintain the rigidity of an anesthetized mouse during transport between scanners. Movement of the bony structures of the mouse was estimated to be 0.62 mm. Soft tissue movement was predominantly the result of the filling (or emptying of the urinary bladder and thus largely constrained to this region. Phantom studies estimate the registration errors for all registration types to be less than 0.5 mm. Functional images using tracers targeted to known structures verify the accuracy of the functional to structural registrations. The procedures are easy to perform and produce robust and accurate results that rival those of dedicated multimodality scanners, but with more flexible registration combinations and while avoiding the expense and redundancy of multimodality systems.

  7. A new methodological approach for PET implementation in radiotherapy treatment planning.

    Science.gov (United States)

    Bellan, Elena; Ferretti, Alice; Capirci, Carlo; Grassetto, Gaia; Gava, Marcello; Chondrogiannis, Sotirios; Virdis, Graziella; Marzola, Maria Cristina; Massaro, Arianna; Rubello, Domenico; Nibale, Otello

    2012-05-01

    In this paper, a new methodological approach to using PET information in radiotherapy treatment planning has been discussed. Computed tomography (CT) represents the primary modality to plan personalized radiation treatment, because it provides the basic electron density map for correct dose calculation. If PET scanning is also performed it is typically coregistered with the CT study. This operation can be executed automatically by a hybrid PET/CT scanner or, if the PET and CT imaging sets have been acquired through different equipment, by a dedicated module of the radiotherapy treatment planning system. Both approaches have some disadvantages: in the first case, the bore of a PET/CT system generally used in clinical practice often does not allow the use of certain bulky devices for patient immobilization in radiotherapy, whereas in the second case the result could be affected by limitations in window/level visualization of two different image modalities, and the displayed PET volumes can appear not to be related to the actual uptake into the patient. To overcome these problems, at our centre a specific procedure has been studied and tested in 30 patients, allowing good results of precision in the target contouring to be obtained. The process consists of segmentation of the biological target volume by a dedicated PET/CT console and its export to a dedicated radiotherapy system, where an image registration between the CT images acquired by the PET/CT scanner and a large-bore CT is performed. The planning target volume is contoured only on the large-bore CT and is used for virtual simulation, to individuate permanent skin markers on the patient.

  8. Report on the interpretation of critical experiments in the Siemens-Argonaut-Reactor Graz to study water ingress into spherical elements. Ergebnisbericht zur Auslegung kritischer Experimente am Siemens-Argonaut-Reaktor Graz zum Studium des Wassereinbruches im Kugelhaufen

    Energy Technology Data Exchange (ETDEWEB)

    Schuerrer, F [Technische Univ., Graz (Austria). Inst. fuer Theoretische Physik und Reaktorphysik; Neef, R D [Kernforschungsanlage Juelich G.m.b.H. (Germany, F.R.). Inst. fuer Reaktorentwicklung

    1979-04-15

    The experiments described are of interest in the study of water contamination in HTR fuel elements. The Siemens Argonaut Reactor (SAR) has been considered as a research tool for a simulation experiment. Following a brief description of the SAR, planned programs are discussed in 'dry' and 'wet' cores. Detector foil types and locations are noted. A theoretical model is developed and nuclide concentrations estimated in the various spectral zones. Reactivity calculations have been made and are summarised for various H{sub 2}O percentage concentrations. The discussion is supported by simplified core layout diagrams and graphs of core flux distributions. Neutron diffusion and spectra calculations are referenced to computer programs used by KFA-Juelich, published elsewhere, and include GAM, THERMOS, MUPO and EXTERMINATOR-2. (G.C.)

  9. The usefulness of F-18 FDG whole body PET in the evaluation of postoperative recurrence of cancer

    International Nuclear Information System (INIS)

    Kang, Won Jun; So, Young; Jeong, Jae Min

    1997-01-01

    The purpose of this study was to evaluate the usefulness of whole body F-18 FDG PET scan for detecting postoperative recurrence of cancer. One hundred four cancer patients after operation were enrolled (14 brain tumor, 15 head and neck cancer, 23 gynecologic cancer, 16 gastrointestinal cancer, 16 thyroid cancer, and 20 other cancers). Besides conventional images (CI) including CT and MRI, F-18 FDG PET scan was obtained on ECAT EXACT 47 scanner (Siemens- CTI), beginning 60 minutes after injection of 370MBq(10mCi) of F-18 FDG. Regional scan was also obtained with emission image. Transmission images using Ge-68 were carried out for attenuation correction in both whole body and regional images. Findings of PET and CI were confirmed by pathology or clinical follow up. The sensitivity and specificity of PET for detecting recurrence were 94% and 92%, respectively. Contrarily, the sensitivity and specificity of CI were 78% and 68%. CI results were negative and PET results were positive in 11 cases. The biopsy or clinical follow-up of those cases confirmed recurrence of tumor. False negative cases of CI were frequent in patients with gynecologic cancers. Also we measured the serum concentration of tumor markers in patients with gynecologic cancer (CA125), thyroid cancer (thyroglobulin), and colorectal cancer (CEA). The sensitivity and specificity of tumor markers were 71% and 84%, respectively. We conclude that F-18 FDG PET can be used valuably in detecting recurrent foci of a wide variety of malignancy compared to conventional diagnostic methods

  10. A fast preamplifier concept for SiPM-based time-of-flight PET detectors

    NARCIS (Netherlands)

    Huizenga, J.; Seifert, S.; Schreuder, F.; Dendooven, P.; Löhner, H.; Vinke, R.; Schaart, D. R.; van Dam, H.T.

    2012-01-01

    Silicon photomultipliers (SiPMs) offer high gain and fast response to light, making them interesting for fast timing applications such as time-of-flight (TOF) PET. To fully exploit the potential of these photosensors, dedicated preamplifiers that do not deteriorate the rise time and signal-to-noise

  11. PET studies in epilepsy

    Science.gov (United States)

    Sarikaya, Ismet

    2015-01-01

    Various PET studies, such as measurements of glucose, serotonin and oxygen metabolism, cerebral blood flow and receptor bindings are availabe for epilepsy. 18Fluoro-2-deoxyglucose (18F-FDG) PET imaging of brain glucose metabolism is a well established and widely available technique. Studies have demonstrated that the sensitivity of interictal FDG-PET is higher than interictal SPECT and similar to ictal SPECT for the lateralization and localization of epileptogenic foci in presurgical patients refractory to medical treatments who have noncontributory EEG and MRI. In addition to localizing epileptogenic focus, FDG-PET provide additional important information on the functional status of the rest of the brain. The main limitation of interictal FDG-PET is that it cannot precisely define the surgical margin as the area of hypometabolism usually extends beyond the epileptogenic zone. Various neurotransmitters (GABA, glutamate, opiates, serotonin, dopamine, acethylcholine, and adenosine) and receptor subtypes are involved in epilepsy. PET receptor imaging studies performed in limited centers help to understand the role of neurotransmitters in epileptogenesis, identify epileptic foci and investigate new treatment approaches. PET receptor imaging studies have demonstrated reduced 11C-flumazenil (GABAA-cBDZ) and 18F-MPPF (5-HT1A serotonin) and increased 11C-cerfentanil (mu opiate) and 11C-MeNTI (delta opiate) bindings in the area of seizure. 11C-flumazenil has been reported to be more sensitive than FDG-PET for identifying epileptic foci. The area of abnormality on GABAAcBDZ and opiate receptor images is usually smaller and more circumscribed than the area of hypometabolism on FDG images. Studies have demonstrated that 11C-alpha-methyl-L-tryptophan PET (to study synthesis of serotonin) can detect the epileptic focus within malformations of cortical development and helps in differentiating epileptogenic from non-epileptogenic tubers in patients with tuberous sclerosis complex

  12. Use of commercial grade item dedication to reduce procurement costs

    International Nuclear Information System (INIS)

    Rosch, F.

    1995-01-01

    In the mid-1980s, the Nuclear Regulatory Industry (NRC) began inspecting utility practices of procuring and dedicating commercial grade items intended for plant safety-related applications. As a result of the industry efforts to address NRC concerns, nuclear utilities have enhanced existing programs and procedures for dedication of commercial grade items. Though these programs were originally enhanced to meet NRC concerns, utilities have discovered that the dedication of commercial grade items can also reduce overall procurement costs. This paper will discuss the enhancement of utility dedication programs and demonstrates how utilities have utilized them to reduce procurement costs

  13. PET and Recycling

    OpenAIRE

    Funda Sevencan; Songul A. Vaizoglu

    2007-01-01

    This review aims to clarify the need of decreasing the environmental effects caused by human and draw attention to the increasing environmental effects of plastics wastes. Plastics consist of organic molecules with high density molecules or polymers. Main resources of plastics are the residue of oil rafineries. Several advantages of plastics, have increased the usage continuously. Polyethylene Terephthalate (PET) is the most commonly used plastics. PET is used to protect food, drinking water,...

  14. Towards Implementing an MR-based PET Attenuation Correction Method for Neurological Studies on the MR-PET Brain Prototype

    Science.gov (United States)

    Catana, Ciprian; van der Kouwe, Andre; Benner, Thomas; Michel, Christian J.; Hamm, Michael; Fenchel, Matthias; Fischl, Bruce; Rosen, Bruce; Schmand, Matthias; Sorensen, A. Gregory

    2013-01-01

    A number of factors have to be considered for implementing an accurate attenuation correction (AC) in a combined MR-PET scanner. In this work, some of these challenges were investigated and an AC method based entirely on the MR data obtained with a single dedicated sequence was developed and used for neurological studies performed with the MR-PET human brain scanner prototype. Methods The focus was on the bone/air segmentation problem, the bone linear attenuation coefficient selection and the RF coil positioning. The impact of these factors on the PET data quantification was studied in simulations and experimental measurements performed on the combined MR-PET scanner. A novel dual-echo ultra-short echo time (DUTE) MR sequence was proposed for head imaging. Simultaneous MR-PET data were acquired and the PET images reconstructed using the proposed MR-DUTE-based AC method were compared with the PET images reconstructed using a CT-based AC. Results Our data suggest that incorrectly accounting for the bone tissue attenuation can lead to large underestimations (>20%) of the radiotracer concentration in the cortex. Assigning a linear attenuation coefficient of 0.143 or 0.151 cm−1 to bone tissue appears to give the best trade-off between bias and variability in the resulting images. Not identifying the internal air cavities introduces large overestimations (>20%) in adjacent structures. Based on these results, the segmented CT AC method was established as the “silver standard” for the segmented MR-based AC method. Particular to an integrated MR-PET scanner, ignoring the RF coil attenuation can cause large underestimations (i.e. up to 50%) in the reconstructed images. Furthermore, the coil location in the PET field of view has to be accurately known. Good quality bone/air segmentation can be performed using the DUTE data. The PET images obtained using the MR-DUTE- and CT-based AC methods compare favorably in most of the brain structures. Conclusion An MR-DUTE-based AC

  15. Accuracy evaluation of distance inverse square law in determining virtual electron source location in Siemens Primus linac.

    Science.gov (United States)

    Douk, Hamid Shafaei; Aghamiri, Mahmoud Reza; Ghorbani, Mahdi; Farhood, Bagher; Bakhshandeh, Mohsen; Hemmati, Hamid Reza

    2018-01-01

    The aim of this study is to evaluate the accuracy of the inverse square law (ISL) method for determining location of virtual electron source ( S Vir ) in Siemens Primus linac. So far, different experimental methods have presented for determining virtual and effective electron source location such as Full Width at Half Maximum (FWHM), Multiple Coulomb Scattering (MCS), and Multi Pinhole Camera (MPC) and Inverse Square Law (ISL) methods. Among these methods, Inverse Square Law is the most common used method. Firstly, Siemens Primus linac was simulated using MCNPX Monte Carlo code. Then, by using dose profiles obtained from the Monte Carlo simulations, the location of S Vir was calculated for 5, 7, 8, 10, 12 and 14 MeV electron energies and 10 cm × 10 cm, 15 cm × 15 cm, 20 cm × 20 cm and 25 cm × 25 cm field sizes. Additionally, the location of S Vir was obtained by the ISL method for the mentioned electron energies and field sizes. Finally, the values obtained by the ISL method were compared to the values resulted from Monte Carlo simulation. The findings indicate that the calculated S Vir values depend on beam energy and field size. For a specific energy, with increase of field size, the distance of S Vir increases for most cases. Furthermore, for a special applicator, with increase of electron energy, the distance of S Vir increases for most cases. The variation of S Vir values versus change of field size in a certain energy is more than the variation of S Vir values versus change of electron energy in a certain field size. According to the results, it is concluded that the ISL method can be considered as a good method for calculation of S Vir location in higher electron energies (14 MeV).

  16. Guide to clinical PET in oncology: Improving clinical management of cancer patients

    International Nuclear Information System (INIS)

    2008-10-01

    information on clinical PET in oncology for nuclear medicine physicians, radiologists and clinical practitioners. Possible ideas for cost effectiveness of clinical PET in oncology are mentioned. The information is also intended to be useful in decision making to improve clinical management of cancer patients when allocating resources dedicated to the health care system. This is a critical issue that is important for the development of both clinical oncology and nuclear medicine in IAEA member states. The IAEA can be instrumental in the advancement of programmes which focus on the IAEA's coordinated research projects and technical cooperation project

  17. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    Science.gov (United States)

    Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Aarsvold, John N.; Raghunath, Nivedita; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.; Votaw, John R.

    2012-01-01

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [11C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET

  18. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Fei, Baowei, E-mail: bfei@emory.edu [Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1841 Clifton Road Northeast, Atlanta, Georgia 30329 (United States); Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia 30322 (United States); Department of Mathematics and Computer Sciences, Emory University, Atlanta, Georgia 30322 (United States); Yang, Xiaofeng; Nye, Jonathon A.; Raghunath, Nivedita; Votaw, John R. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Aarsvold, John N. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Nuclear Medicine Service, Atlanta Veterans Affairs Medical Center, Atlanta, Georgia 30033 (United States); Cervo, Morgan; Stark, Rebecca [The Medical Physics Graduate Program in the George W. Woodruff School, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Meltzer, Carolyn C. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Department of Neurology and Department of Psychiatry and Behavior Sciences, Emory University School of Medicine, Atlanta, Georgia 30322 (United States)

    2012-10-15

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [{sup 11}C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

  19. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    International Nuclear Information System (INIS)

    Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Raghunath, Nivedita; Votaw, John R.; Aarsvold, John N.; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.

    2012-01-01

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with ["1"1C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

  20. In-beam PET at high-energy photon beams: a feasibility study

    Science.gov (United States)

    Müller, H.; Enghardt, W.

    2006-04-01

    For radiation therapy with carbon ion beams, either for the stable isotope 12C or for the radioactive one 11C, it has been demonstrated that the β+-activity distribution created or deposited, respectively, within the irradiated volume can be visualized by means of positron emission tomography (PET). The PET images provide valuable information for quality assurance and precision improvement of ion therapy. Dedicated PET scanners have been integrated into treatment sites at the Heavy Ion Medical Accelerator at Chiba (HIMAC), Japan, and the Gesellschaft für Schwerionenforschung (GSI), Germany, to make PET imaging feasible during therapeutic irradiation (in-beam PET). A similar technique may be worthwhile for radiotherapy with high-energy bremsstrahlung. In addition to monitoring the dose delivery process which in-beam PET has been primarily developed for, it may be expected that radiation response of tissue can be detected by means of in-beam PET. We investigate the applicability of PET for treatment control in the case of using bremsstrahlung spectra produced by 15-50 MeV electrons. Target volume activation due to (γ, n) reactions at energies above 20 MeV yields moderate β+-activity levels, which can be employed for imaging. The radiation from positrons produced by pair production is not presently usable because the detectors are overloaded due to the low duty factor of medical electron linear accelerators. However, the degradation of images caused by positron motion between creation and annihilation seems to be tolerable.

  1. Energy Secretary Dedicates ESIF at NREL | News | NREL

    Science.gov (United States)

    3 » Energy Secretary Dedicates ESIF at NREL Energy Secretary Dedicates ESIF at NREL September 18 prey. Enlarge image Energy Secretary Ernest Moniz (center) joins NREL Director Dan Arvizu (left) and newest Energy Department supercomputer. The high performance computer inside NREL's new Energy Systems

  2. Dedicated auxiliary power units for Hybrid Electric Vehicles

    NARCIS (Netherlands)

    Mourad, S.; Weijer, C.J.T. van de

    1998-01-01

    The use of a dedicated auxiliary power unit is essential to utilize the potential that hybrid vehicles offer for efficient and ultra-clean transportation. An example of a hybrid project at the TNO Road-Vehicles Research Institute shows the development and the results of a dedicated auxiliary power

  3. Coherence in Professional Education: Does It Foster Dedication and Identification?

    Science.gov (United States)

    Heggen, Kåre; Terum, Lars Inge

    2013-01-01

    This article examines the impact of professional education on students' dedication to and identification with a profession. The premise is that professional education is not only about knowledge acquisition and reasoning but also about attitudes and aspirations. In fostering dedication and identification, students' experiences of relevance seem to…

  4. Detector design issues for compact nuclear emission cameras dedicated to breast imaging

    International Nuclear Information System (INIS)

    Levin, Craig S.

    2003-01-01

    Certain gamma ray and positron emitting radiotracers have shown great promise for use in the detection, diagnosis and staging of breast cancer. Unfortunately, standard nuclear emission cameras (SPECT, PET) found in the clinic are not practical for breast imaging of these emissions due to inadequate spatial and energy resolutions and sensitivity, large and awkward size, and relatively high cost per study. High spatial and energy resolutions and sensitivity are needed for good lesion detectability. Due to these limitations of standard cameras, there has been recent research into the development of small, compact nuclear emission imagers dedicated for close-proximity breast imaging. The small detector head size means a variety of exotic detectors or collimators may be implemented to improve spatial and energy resolution and sensitivity performances at a reasonable cost. In this paper, we will present some of the compact gamma ray and annihilation photon imaging detector designs that have been proposed and/or developed for dedicated breast imaging. We will review the physics and discuss the advantages and disadvantages of various detector configurations. Finally we will estimate the fundamental spatial resolution potential available with close-proximity nuclear emission imaging and discuss how one may approach those limits through proper detector design

  5. Decreased occipital lobe metabolism by FDG-PET/CT

    Science.gov (United States)

    Solnes, Lilja; Nalluri, Abhinav; Cohen, Jesse; Jones, Krystyna M.; Zan, Elcin; Javadi, Mehrbod S.; Venkatesan, Arun

    2017-01-01

    Objective: To compare brain metabolism patterns on fluorodeoxyglucose (FDG)-PET/CT in anti–NMDA receptor and other definite autoimmune encephalitis (AE) and to assess how these patterns differ between anti–NMDA receptor neurologic disability groups. Methods: Retrospective review of clinical data and initial dedicated brain FDG-PET/CT studies for neurology inpatients with definite AE, per published consensus criteria, treated at a single academic medical center over a 10-year period. Z-score maps of FDG-PET/CT were made using 3-dimensional stereotactic surface projections in comparison to age group–matched controls. Brain region mean Z scores with magnitudes ≥2.00 were interpreted as significant. Comparisons were made between anti–NMDA receptor and other definite AE patients as well as among patients with anti–NMDA receptor based on modified Rankin Scale (mRS) scores at the time of FDG-PET/CT. Results: The medial occipital lobes were markedly hypometabolic in 6 of 8 patients with anti–NMDA receptor encephalitis and as a group (Z = −4.02, interquartile range [IQR] 2.14) relative to those with definite AE (Z = −2.32, 1.46; p = 0.004). Among patients with anti–NMDA receptor encephalitis, the lateral and medial occipital lobes were markedly hypometabolic for patients with mRS 4–5 (lateral occipital lobe Z = −3.69, IQR 1; medial occipital lobe Z = −4.08, 1) compared with those with mRS 0–3 (lateral occipital lobe Z = −0.83, 2; p occipital lobe Z = −1.07, 2; p = 0.001). Conclusions: Marked medial occipital lobe hypometabolism by dedicated brain FDG-PET/CT may serve as an early biomarker for discriminating anti–NMDA receptor encephalitis from other AE. Resolution of lateral and medial occipital hypometabolism may correlate with improved neurologic status in anti–NMDA receptor encephalitis. PMID:29159205

  6. Medical application of PET technology

    International Nuclear Information System (INIS)

    Lim, Sang Moo; Choi, C. W.; An, S. H.; Woo, K. S.; Chung, W. S.; Yang, S. D.; Jun, G. S. and others

    1999-04-01

    We performed following studies using PET technology: 1. Clinical usefulness of [ 18 F]FDG whole body PET in malignant disease 2. Clinical usefulness of quantitative evaluation of F-18-FDG 3. Pilot study of C-11 methionine PET in brain tumor 4. PET study in patients with Parkinson's disease 5. A study on the clinical myocardial PET image. PET gives various metabolic information for the living human body, and is very important, new diagnostic modality. The PET study will give us the information of cancer patients such as early detection of cancer, staging, recurrence detection and characterization of cancer. The quantitative analysis using PET could be applied to evaluate the pathophysiology of various diseases and develop new drugs and develop new radiopharmaceuticals

  7. PET in neuro-oncology

    NARCIS (Netherlands)

    Roelcke, U; Leenders, K.L.

    This article reviews possible clinical applications of positron emission tomography (PET) in brain tumor patients. PET allows quantitative assessment of brain tumor pathophysiology and biochemistry. It therefore provides different information about tumors when compared to histological or

  8. Take Care with Pet Reptiles

    Science.gov (United States)

    ... young children. [775 KB] Animals and Health Healthy Pets Healthy People : CDC website with helpful resources and information on health benefits of pets and disease risks Safe Handling Tips for Reptiles ...

  9. Medical application of PET technology

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Moo; Choi, C. W.; An, S. H.; Woo, K. S.; Chung, W. S.; Yang, S. D.; Jun, G. S. and others

    1999-04-01

    We performed following studies using PET technology: 1. Clinical usefulness of [{sup 18}F]FDG whole body PET in malignant disease 2. Clinical usefulness of quantitative evaluation of F-18-FDG 3. Pilot study of C-11 methionine PET in brain tumor 4. PET study in patients with Parkinson's disease 5. A study on the clinical myocardial PET image. PET gives various metabolic information for the living human body, and is very important, new diagnostic modality. The PET study will give us the information of cancer patients such as early detection of cancer, staging, recurrence detection and characterization of cancer. The quantitative analysis using PET could be applied to evaluate the pathophysiology of various diseases and develop new drugs and develop new radiopharmaceuticals.

  10. PET applications in pediatrics

    Energy Technology Data Exchange (ETDEWEB)

    Shulkin, B. L. [Ann Arbor, Univ. of Michigan Medical Center (United States). Pediatric Nuclear Medicine Section

    1997-12-01

    This article summarizes the major PET studies which have been performed in pediatric patients to elucidate and characterize diseases and normal development. Issues special for the application of the technique in children, such as dosimetry, patient preparation, and image acquisition are discussed. Studies of central nervous system (CNS) development and pathology, including epilepsy, intraventricular hemorrhage, neonatal asphyxia, tumors, and effects on the CNS from treatment of other tumors are reviewed. These have contributed information fundamental to their understanding of CNS development and pathology. PET investigations into the pathophysiology of congenital heart disease have begun and hold great promise to aid their understanding of these conditions. The second major area in which PET has been applied is the study of non CNS neoplasms. Neuroblastoma has been investigated with tracers which explore basic biochemical features which characterize this tumor, as well as with tracers which explore biochemical events relatively specific for this malignancy. Other common and uncommon tumors of childhood are discussed. The PET technique has been shown useful for answering questions of clinical relevance for the management of these uncommon neoplasms. PET is likely to continue to aid their understanding of many pediatric diseases and may gain more widespread clinical acceptance as the technology continues to disseminate rapidly.

  11. Combined PET/MRI

    DEFF Research Database (Denmark)

    Bailey, D L; Pichler, B J; Gückel, B

    2018-01-01

    The 6th annual meeting to address key issues in positron emission tomography (PET)/magnetic resonance imaging (MRI) was held again in Tübingen, Germany, from March 27 to 29, 2017. Over three days of invited plenary lectures, round table discussions and dialogue board deliberations, participants c...... of response to pharmacological interventions and therapies. As such, PET/MRI is a key to advancing medicine and patient care.......The 6th annual meeting to address key issues in positron emission tomography (PET)/magnetic resonance imaging (MRI) was held again in Tübingen, Germany, from March 27 to 29, 2017. Over three days of invited plenary lectures, round table discussions and dialogue board deliberations, participants...... critically assessed the current state of PET/MRI, both clinically and as a research tool, and attempted to chart future directions. The meeting addressed the use of PET/MRI and workflows in oncology, neurosciences, infection, inflammation and chronic pain syndromes, as well as deeper discussions about how...

  12. Comprehensive Approach to Energy and Environment in the EcoCare Program for Design, Engineering and Operation of Siemens Industry Solutions

    DEFF Research Database (Denmark)

    Wegener, Dieter; Finkbeiner, Matthias; Geiger, Dieter

    2009-01-01

    This paper intends to describe the outline of the Eco Care Program (ECP) at the Siemens-Division Industry Solutions and its implementation. ECP aims to embrace and to coordinate main activities within the product lifecycle management (PLM) process considering both economic targets in terms...

  13. Specific recommendations for accurate and direct use of PET-CT in PET guided radiotherapy for head and neck sites

    International Nuclear Information System (INIS)

    Thomas, C. M.; Convery, D. J.; Greener, A. G.; Pike, L. C.; Baker, S.; Woods, E.; Hartill, C. E.

    2014-01-01

    techniques, laser positioning may affect setup accuracy and couch deflection may be greater than scanners dedicated to radiotherapy. The full set of departmental commissioning and routine quality assurance tests applied to radiotherapy CT simulators must be carried out on the PET-CT scanner. CT image quality must be optimized for radiotherapy planning whilst understanding that the appearance will differ between scanners and may affect delineation. PET-CT quality assurance schedules will need to be added to and modified to incorporate radiotherapy quality assurance. Methods of working for radiotherapy and PET staff will change to take into account considerations of both parties. PET to CT alignment must be subject to quality control on a loaded and unloaded couch preferably using a suitable emission phantom, and tested throughout the whole data pathway. Data integrity must be tested throughout the whole pathway and a system included to verify that delineated structures are transferred correctly. Excellent multidisciplinary team communication and working is vital, and key staff members on both sides should be specifically dedicated to the project. Patient pathway should be clearly devised to optimize patient care and the resources of all departments. Recruitment of a cohort of patients into a methodology study is valuable to test the quality assurance methods and pathway

  14. Specific recommendations for accurate and direct use of PET-CT in PET guided radiotherapy for head and neck sites

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, C. M., E-mail: christopher.thomas@gstt.nhs.uk; Convery, D. J.; Greener, A. G. [Guy' s and St. Thomas’ NHS Foundation Trust, Medical Physics Department, St. Thomas’ Hospital, London SE1 7EH (United Kingdom); Pike, L. C.; Baker, S.; Woods, E. [Division of Imaging Sciences and Biomedical Engineering, King' s College London, King' s Health Partners, St. Thomas’ Hospital, London SE1 7EH (United Kingdom); Hartill, C. E. [Guy' s and St. Thomas’ NHS Foundation Trust, Radiotherapy, Clinical Outpatients Clinic, St. Thomas’ Hospital, London SE1 7EH (United Kingdom)

    2014-04-15

    techniques, laser positioning may affect setup accuracy and couch deflection may be greater than scanners dedicated to radiotherapy. The full set of departmental commissioning and routine quality assurance tests applied to radiotherapy CT simulators must be carried out on the PET-CT scanner. CT image quality must be optimized for radiotherapy planning whilst understanding that the appearance will differ between scanners and may affect delineation. PET-CT quality assurance schedules will need to be added to and modified to incorporate radiotherapy quality assurance. Methods of working for radiotherapy and PET staff will change to take into account considerations of both parties. PET to CT alignment must be subject to quality control on a loaded and unloaded couch preferably using a suitable emission phantom, and tested throughout the whole data pathway. Data integrity must be tested throughout the whole pathway and a system included to verify that delineated structures are transferred correctly. Excellent multidisciplinary team communication and working is vital, and key staff members on both sides should be specifically dedicated to the project. Patient pathway should be clearly devised to optimize patient care and the resources of all departments. Recruitment of a cohort of patients into a methodology study is valuable to test the quality assurance methods and pathway.

  15. Combined FDG PET/CT imaging for restaging of colorectal cancer patients: impact of image fusion on staging accuracy

    International Nuclear Information System (INIS)

    Strunk, H.; Jaeger, U.; Flacke, S.; Hortling, N.; Bucerius, J.; Joe, A.; Reinhardt, M.; Palmedo, H.

    2005-01-01

    Purpose: To evaluate the diagnostic impact of positron emission tomography (PET) with fluorine-18-labeled deoxy-D-glucose (FDG) combined with non-contrast computed tomography (CT) as PET-CT modality in restaging colorectal cancer patients. Material and methods: In this retrospective study, 29 consecutive patients with histologically proven colorectal cancer (17 female, 12 male, aged 51-76 years) underwent whole body scans in one session on a dual modality PET-CT system (Siemens Biograph) 90 min. after i.v. administration of 370 MBq 18 F-FDG. The CT imaging was performed with 40 mAs, 130 kV, slice-thickness 5 mm and without i.v. contrast administration. PET and CT images were reconstructed with a slice-thickness of 5 mm in coronal, sagittal and transverse planes. During a first step of analysis, PET and CT images were scored blinded and independently by a group of two nuclear medicine physicians and a group of two radiologists, respectively. For this purpose, a five-point-scale was used. The second step of data-analysis consisted of a consensus reading by both groups. During the consensus reading, first a virtual (meaning mental) fusion of PET and CT images and afterwards the 'real' fusion (meaning coregistered) PET-CT images were also scored with the same scale. The imaging results were compared with histopathology findings and the course of disease during further follow-up. Results: The total number of malignant lesions detected with the combined PET/CT were 86. For FDG-PET alone it was n=68, and for CT alone n=65. Comparing PET-CT and PET, concordance was found in 81 of 104 lesions. Discrepancies predominantly occurred in the lung, where PET alone often showed true positive results in lymph nodes and soft tissue masses, where CT often was false negative. Comparing mental fusion and 'real' co-registered images, concordance was found in 94 of 104 lesions. In 13 lesions or, respectively, in 7 of 29 patients, a relevant information was gathered using fused images

  16. PET imaging in multiple sclerosis

    NARCIS (Netherlands)

    Faria, Daniele de Paula; Copray, Sjef; Buchpiguel, Carlos; Dierckx, Rudi; de Vries, Erik

    Positron emission tomography (PET) is a non-invasive technique for quantitative imaging of biochemical and physiological processes in animals and humans. PET uses probes labeled with a radioactive isotope, called PET tracers, which can bind to or be converted by a specific biological target and thus

  17. 18FFDG PET in evaluating malignancies compared with CT, MRI and pathology in 58 cases

    International Nuclear Information System (INIS)

    Li, L.

    2000-01-01

    This article discussed the practical application of 18 F-FDG PET imaging techniques to depict, state, or define recurrences for five important malignancies: lung cancer, colorectal and head-and-neck cancer, intracranial malignant glioma and primary or secondary hepatic malignant diseases. And comparisons of 18 F-FDG PET with CT, MRI imaging were addressed specifically. We reviewed our initial experience with 48 malignant and ten non-malignant cases. Among malignant group, 36 cases were confirmed by operation or biopsy, Other ten non-malignant diseases, including brain infarction, post-radiotherapy necrosis or scar and lung abscesses were followed with CT or MRI at least 6 months. All patients received intravenous administration of 18 F-FDG 10-15 mCi, followed by a 40 minutes uptake phase, and subsequent imaged using a Siemens ECAT 931 whole-body scanner with resolution of 4 mm FWHM in the center of the field of view. Filtered back projection reconstruction was used to display attenuated or non-attenuated corrected images. The result of 18 F-FDG PET was retrospectively evaluated to assess the degree of uptake of 18 F-FDG PET in the tumor tissues and compared with CT, MRI and pathology. CT and MRI exam were taken before or after PET study in two weeks. 18 F-FDG PET scans showed a significantly increased FDG metabolism in 47 malignant lesions, The tumor / normal tissue FDG uptake rate were 4.16 ±2.11. In 47 cases with neoplasm, 18 F-FDG PET findings were constant with or further confirmed the CT or MRI diagnosis in 35/47 (74.5%) and 12/47 (253%) cases. Another one small intracranial metastasis ( 18 F-FDG PET imaging in oncology has demonstrated powerful advantage in characterizing tumor lesions, differentiating recurrent disease from treatment effects, staging tumors, evaluating the extent of disease, and monitoring therapy. But 18 F-FDG PET still cant replace CT or MRI in malignance diagnosis. It will be used to approach and hopefully answer the difficult diagnosis

  18. Clinical value of FDG-PET in cutaneous malignant melanoma: First experience in Estonia

    International Nuclear Information System (INIS)

    Nazarenko, S.; Niin, M.; Paats, A.; Tonnov, A.

    2004-01-01

    Full text: In November 2002 first 18F-FDG-PET was performed in Estonia using a mobile truck-mounted scanning technology (Accel, Siemens) provided by the International Healthcare Group (IHG, Amersfoort, Netherlands). The FDG was provided by MAP Medical Technologies, Schering, (Helsinki, Finland). In 2003 this scheme was repeated for further scanning sessions. Evaluation of cutaneous malignant melanoma (CMM) using nuclear technique is of particular interest in Estonia as its incidence is on the rise. F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) in CMM has a well-documented high diagnostic accuracy, especially in staging of the disease. The aim of the current study was to assess the impact of 18F-FDG-PET on detailed staging and clinical management in CMM. 30 patients of CMM, 16 males and 14 females, all non-diabetic, in the age range of 26 to 69 years were studied. Of these 30 patients, 12 were of high risk primary CMM, 7 had regional lymph node metastases and 11 had distant metastases. Patients were asked to consume a low-carbohydrate diet 3 days prior to the FDG-PET scan. 194 to 410 MBq (average 335 MBq) 18F-FDG was administered to the patients who were asked to come fasting for a minimum of 6 hours. Whole body scan was performed 40 to 65 minutes after the administration of FDG on the mobile PET. In 13 of the 30 patients (43%) 18F-FDG-PET changed the staging. In remaining 17 patients (57%) 18F-FDG-PET increased confidence level for the chosen treatment. Lymphadenectomy was planned in 2 patients showing lymph node involvement on FDG-PET. In other 2 patients, one with small pulmonary and other with a liver lesions found on PET but negative on radiological examination 'wait-and-watch' strategy was chosen. An unexpected hypermetabolic lesion seen in 1 case turned out to be a benign focus of connective tissue. One patient shown to have multiple distant metastases was started on chemotherapy. Finally in 8 of the 30 (27%) patients an immediate positive

  19. PET imaging of inflammation

    International Nuclear Information System (INIS)

    Buscombe, J. R.

    2014-01-01

    Inflammatory diseases are common place and often chronic. Most inflammatory cells have increased uptake of glucose which is enhanced in the presence of local cytokines. Therefore, imaging glucose metabolism by the means of 18F-fluoro-deoxy-glucose (FDG) positron emission tomography (PET) holds significant promise in imaging focal inflammation. Most of the work published involved small series of patients with either vasculitis, sarcoid or rheumatoid arthritis. It would appear that FDG PET is a simple and effective technique to identify inflammatory tissue in these conditions. There is even some work to suggest that by comparing baseline and early post therapy scans clinical outcome can be predicted. This would appear to be true with vasculitis as well as retroperitoneal fibrosis. The number of patients in each study is small but the evidence is compelling enough to recommend FDG PET imaging in the routine care of these patients.

  20. Pet in Clinical oncology

    International Nuclear Information System (INIS)

    Hunsche, A.; Grossman, G.; Santana, M.; Santana, C.; Halkar, R.; Garcia, E.

    2003-01-01

    The utility of the PET (positron emission tomography in clinical oncology has been recognized for more than two decades, locating it as a sensible technique for the diagnosis and the prognosis stratification of the oncology patients. The sensitivity and specificity of the PET in comparation to other image studies have demonstrated to be greater. For some years, there was a restriction of PET because of the high cost of the equipment and the cyclotrons. Nevertheless, the relation of cost/benefits is considered as a priority as this technique offers important clinical information. In this article the results observed when using it in diverse types of cancer, as well as the effectiveness shown in the pre-operating evaluation, the evaluation of residual disease, diagnosis of recurrences, pursuit and prognosis stratification of the patients with cancer. (The author)

  1. Metabolic imaging using PET

    International Nuclear Information System (INIS)

    Kudo, Takashi

    2007-01-01

    There is growing evidence that myocardial metabolism plays a key role not only in ischaemic heart disease but also in a variety of diseases which involve myocardium globally, such as heart failure and diabetes mellitus. Understanding myocardial metabolism in such diseases helps to elucidate the pathophysiology and assists in making therapeutic decisions. As well as providing information on regional changes, PET can deliver quantitative information about both regional and global changes in metabolism. This capability of quantitative measurement is one of the major advantages of PET along with physiological positron tracers, especially relevant in evaluating diseases which involve the whole myocardium. This review discusses major PET tracers for metabolic imaging and their clinical applications and contributions to research regarding ischaemic heart disease and other diseases such as heart failure and diabetic heart disease. Future applications of positron metabolic tracers for the detection of vulnerable plaque are also highlighted briefly. (orig.)

  2. PET functional volume delineation: a robustness and repeatability study

    International Nuclear Information System (INIS)

    Hatt, Mathieu; Cheze-le Rest, Catherine; Albarghach, Nidal; Pradier, Olivier; Visvikis, Dimitris

    2011-01-01

    Current state-of-the-art algorithms for functional uptake volume segmentation in PET imaging consist of threshold-based approaches, whose parameters often require specific optimization for a given scanner and associated reconstruction algorithms. Different advanced image segmentation approaches previously proposed and extensively validated, such as among others fuzzy C-means (FCM) clustering, or fuzzy locally adaptive bayesian (FLAB) algorithm have the potential to improve the robustness of functional uptake volume measurements. The objective of this study was to investigate robustness and repeatability with respect to various scanner models, reconstruction algorithms and acquisition conditions. Robustness was evaluated using a series of IEC phantom acquisitions carried out on different PET/CT scanners (Philips Gemini and Gemini Time-of-Flight, Siemens Biograph and GE Discovery LS) with their associated reconstruction algorithms (RAMLA, TF MLEM, OSEM). A range of acquisition parameters (contrast, duration) and reconstruction parameters (voxel size) were considered for each scanner model, and the repeatability of each method was evaluated on simulated and clinical tumours and compared to manual delineation. For all the scanner models, acquisition parameters and reconstruction algorithms considered, the FLAB algorithm demonstrated higher robustness in delineation of the spheres with low mean errors (10%) and variability (5%), with respect to threshold-based methodologies and FCM. The repeatability provided by all segmentation algorithms considered was very high with a negligible variability of <5% in comparison to that associated with manual delineation (5-35%). The use of advanced image segmentation algorithms may not only allow high accuracy as previously demonstrated, but also provide a robust and repeatable tool to aid physicians as an initial guess in determining functional volumes in PET. (orig.)

  3. Novel PET sensors

    International Nuclear Information System (INIS)

    Cooper, C.R.

    2001-03-01

    This thesis describes the design, synthesis and evaluation of novel molecular sensors that utilize the phenomena of Photoinduced Electron Transfer (PET). PET design can be incorporated into molecules to allow them to selectively bind certain guest molecules. PET works by the modulation of electron potentials within a molecule. Binding events between a host and guest can, if designed suitably, change these potentials enough to cause a transfer of electronic charge within the molecular sensor. This event can be accurately and sensitively monitored by the use of ultra violet or fluorescence spectroscopy. A sensor molecule can be constructed by matching the guest to a suitable receptor site and incorporating this into a molecule containing a fluorophore with the correct electron potential characteristics. By using existing synthetic routes as well as exploiting new pathways these sensor molecules C n be constructed to contain a fluorophore separated from a guest receptor(s) by suitable spacers units. When put together these facets go to creating molecules that by design are sensitive and selective for certain guest molecules or functional groups. This methodology allows the synthetic chemist to rationally design and synthesise PET sensors, tailored to the needs of the guest. In this thesis the synthesis and evaluation of a novel PET sensors for D-glucosamine, disaccharides and fluoride is presented. It is believed that the novel sensors using the PET phenomenon presented in this thesis are a worthwhile extension of previous works undertaken by other groups around the world and shows new pathways to increasingly complex and sophisticated sensor molecular design. (author)

  4. Correcting for respiratory motion in liver PET/MRI: preliminary evaluation of the utility of bellows and navigated hepatobiliary phase imaging

    International Nuclear Information System (INIS)

    Hope, Thomas A.; Verdin, Emily F.; Bergsland, Emily K.; Ohliger, Michael A.; Corvera, Carlos University; Nakakura, Eric K.

    2015-01-01

    The purpose of this study was to evaluate the utility of bellows-based respiratory compensation and navigated hepatobiliary phase imaging to correct for respiratory motion in the setting of dedicated liver PET/MRI. Institutional review board approval and informed consent were obtained. Six patients with metastatic neuroendocrine tumor were imaged using Ga-68 DOTA-TOC PET/MRI. Whole body imaging and a dedicated 15-min liver PET acquisition was performed, in addition to navigated and breath-held hepatobiliary phase (HBP) MRI. Liver PET data was reconstructed three ways: the entire data set (liver PET), gated using respiratory bellows (RC-liver PET), and a non-gated data set reconstructed using the same amount of data used in the RC-liver PET (shortened liver PET). Liver lesions were evaluated using SUV max , SUV peak , SUV mean , and Vol isocontour . Additionally, the displacement of each lesion between the RC-liver PET images and the navigated and breath-held HBP images was calculated. Respiratory compensation resulted in a 43 % increase in SUVs compared to ungated data (liver vs RC-liver PET SUV max 26.0 vs 37.3, p < 0.001) and a 25 % increase compared to a non-gated reconstruction using the same amount of data (RC-liver vs shortened liver PET SUV max 26.0 vs 32.6, p < 0.001). Lesion displacement was minimized using navigated HBP MRI (1.3 ± 1.0 mm) compared to breath-held HBP MRI (23.3 ± 1.0 mm). Respiratory bellows can provide accurate respiratory compensation when imaging liver lesions using PET/MRI, and results in increased SUVs due to a combination of increased image noise and reduced respiratory blurring. Additionally, navigated HBP MRI accurately aligns with respiratory compensated PET data.

  5. Correcting for respiratory motion in liver PET/MRI: preliminary evaluation of the utility of bellows and navigated hepatobiliary phase imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hope, Thomas A. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Department of Radiology, San Francisco VA Medical Center, San Francisco, CA (United States); Verdin, Emily F. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Bergsland, Emily K. [Division of Hematology/Oncology, Department of Medicine, University of California, San Francisco, San Francisco, CA (United States); Ohliger, Michael A. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Department of Radiology, San Francisco General Hospital, San Francisco, CA (United States); Corvera, Carlos University; Nakakura, Eric K. [Division of Surgical Oncology, Department of Surgery, University of California, San Francisco, San Francisco, CA (United States)

    2015-09-18

    The purpose of this study was to evaluate the utility of bellows-based respiratory compensation and navigated hepatobiliary phase imaging to correct for respiratory motion in the setting of dedicated liver PET/MRI. Institutional review board approval and informed consent were obtained. Six patients with metastatic neuroendocrine tumor were imaged using Ga-68 DOTA-TOC PET/MRI. Whole body imaging and a dedicated 15-min liver PET acquisition was performed, in addition to navigated and breath-held hepatobiliary phase (HBP) MRI. Liver PET data was reconstructed three ways: the entire data set (liver PET), gated using respiratory bellows (RC-liver PET), and a non-gated data set reconstructed using the same amount of data used in the RC-liver PET (shortened liver PET). Liver lesions were evaluated using SUV{sub max}, SUV{sub peak}, SUV{sub mean}, and Vol{sub isocontour}. Additionally, the displacement of each lesion between the RC-liver PET images and the navigated and breath-held HBP images was calculated. Respiratory compensation resulted in a 43 % increase in SUVs compared to ungated data (liver vs RC-liver PET SUV{sub max} 26.0 vs 37.3, p < 0.001) and a 25 % increase compared to a non-gated reconstruction using the same amount of data (RC-liver vs shortened liver PET SUV{sub max} 26.0 vs 32.6, p < 0.001). Lesion displacement was minimized using navigated HBP MRI (1.3 ± 1.0 mm) compared to breath-held HBP MRI (23.3 ± 1.0 mm). Respiratory bellows can provide accurate respiratory compensation when imaging liver lesions using PET/MRI, and results in increased SUVs due to a combination of increased image noise and reduced respiratory blurring. Additionally, navigated HBP MRI accurately aligns with respiratory compensated PET data.

  6. Markerless 3D Head Tracking for Motion Correction in High Resolution PET Brain Imaging

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter

    relying on markers. Data-driven motion correction is problematic due to the physiological dynamics. Marker-based tracking is potentially unreliable, and it is extremely hard to validate when the tracking information is correct. The motion estimation is essential for proper motion correction of the PET......This thesis concerns application specific 3D head tracking. The purpose is to improve motion correction in position emission tomography (PET) brain imaging through development of markerless tracking. Currently, motion correction strategies are based on either the PET data itself or tracking devices...... images. Incorrect motion correction can in the worst cases result in wrong diagnosis or treatment. The evolution of a markerless custom-made structured light 3D surface tracking system is presented. The system is targeted at state-of-the-art high resolution dedicated brain PET scanners with a resolution...

  7. PET and endocrine tumors

    International Nuclear Information System (INIS)

    Rigo, P.; Belhocine, T.; Hustinx, R.; Foidart-Willems, J.

    2000-01-01

    The authors review the main indications of PET examination, and specifically of 18 FDG, in the assessment of endocrine tumors: of the thyroid, of the parathyroid, of the adrenal and of the pituitary glands. Neuroendocrine tumors, gastro-entero-pancreatic or carcinoid tumors are also under the scope. Usually, the most differentiated tumors show only poor uptake of the FDG as they have a weak metabolic and proliferative activity. In the assessment of endocrine tumors, FDG-PET should be used only after most specific nuclear examinations been performed. (author)

  8. The Quality Control of Intensity Modulated Radiation Therapy (IMRT for ONCOR Siemens Linear Accelerators Using Film Dosimetry

    Directory of Open Access Journals (Sweden)

    Keyvan Jabbari

    2012-03-01

    Full Text Available Introduction Intensity Modulated Radiation Therapy (IMRT has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various steps of planning and quality control of Siemens linear accelerators for IMRT, using film dosimetry. This article in addition to review of the techniques, discusses the details of experiments and possible sources of errors which are not mentioned in the protocols and other references. Materials and Methods This project was carried out in Isfahan Milad hospital which has two Siemens ONCOR linear accelerators. Both accelerators are equipped with Multi-Leaf Collimators (MLC which enables us to perform IMRT delivery in the step-and-shoot method. The quality control consists of various experiments related to the sections of radiation therapy. In these experiments, the accuracy of some components such as treatment planning system, imaging device (CT, MLC, control system of accelerator, and stability of the output are evaluated. The dose verification is performed using film dosimetry method. The films were KODAK-EDR2, which were calibrated before the experiments. One of the important steps is the comparison of the calculated dose with planning system and the measured dose in experiments. Results The results of the experiments in various steps have been acceptable according to the standard protocols. The calibration of MLC and evaluation of the leakage through the leaves of MLC was performed by using the film dosimetry and visual check. In comparison with calculated and measured dose, more that 80% of the points have to be in agreement within 3% of the value. In our experiments, between 85 and 90% of the points had such an agreement with IMRT delivery. Conclusion

  9. Editorial: A dedication to Professor Jan Evetts

    Science.gov (United States)

    Weber, Harald; Dew-Hughes, David; Campbell, Archie; Barber, Zoe; Somekh, Rob; Glowacki, Bartek

    2006-03-01

    A few days before the beginning of the 7th European Conference on Applied Superconductivity we learned that Professor Jan Evetts, a pioneer of superconductor research, a brilliant scientist, a wonderful person and a great personal friend, had passed away. We therefore decided to dedicate the 7th European Conference on Applied Superconductivity to the memory of Jan Evetts. The following citation is based on material provided by his former supervisor (D Dew-Hughes) and his closest co-workers in Cambridge. Professor Jan Edgar Evetts (1939-2005) Professor Jan Edgar Evetts (1939-2005) Jan Evetts passed away after losing his second battle with cancer on 24th August 2005. He made an outstanding series of contributions to the science of superconductivity and to the understanding of superconducting materials and was an indefatigable champion of the development of applications of superconductivity. The loss to the superconductivity community is incalculable, as attested by the many communications received from colleagues throughout the world. Jan was born on 31 March 1939, and attended the Dragon School in Oxford, and later Haileybury. He was awarded an exhibition to read Natural Sciences at Pembroke College, Cambridge. He entered the college in 1958 and took his BA degree in 1961. He then undertook a Certificate of Postgraduate Study in Physics under the supervision of Professor Neville Mott. He was the first student to undertake this newly-instituted course; the title of his thesis was `The Resistance of Transition Metals'. In 1962 he joined David Dew-Hughes' superconducting materials research group, along with Archie Campbell and Anant Narlikar. In fact it was Jan's enthusiasm for the proposed course of research that helped convince David that he should follow Professor Alan Cottrell's suggestion to apply metallurgical methodology to the study of the factors that controlled critical current density in the type II superconductors that were then under development for

  10. Determination of position and shape of flexible mri surface coils using the Microsoft Kinect for attenuation correction in PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Frohwein, Lynn; He, Mirco; Buther, Florian; Safers, Klaus [European Institute for Molecular Imaging, University of Muenster (Germany)

    2015-05-18

    Due to the varying position and shape of flexible MRI RF surface coils, the creation of attenuation maps for these coils is a challenging task. Nevertheless, coil material (metal, plastic, rubber) attenuates the PET signal to a considerable amount. Thus, including a coil μ-map into the human μ-map is essential. In this work, we present a method to determine the position and shape of flexible coils with the help of the Microsoft Kinect depth camera. Phantom PET/MRI (Siemens Biograph mMR) and CT scans (Siemens Biograph mCT) were performed with and without the flexible 32-channel coil equipped with 15 markers visible in CT and Kinect. Prior to the PET/MRI acquisition, Kinect data is acquired of the phantom with the coil on top. The manually extracted marker positions from CT and Kinect are used to non-rigidly transform the template CT according to the Kinect marker positions describing the shape of the coil during PET/MRI acquisition. An appropriate μ-map can then be calculated from the transformed CT dataset. Subsequently, the μ-map is placed in relation to the patient table according to the Kinect-derived marker positions. First results show that the coil shape can be determined with the help of the Kinect camera. The transformation of the template CT dataset according to Kinect marker positions during PET/MRI leads to appropriate results. Furthermore, the position of the coil can also be determined for an accurate placement of the μ-map in relation to the patient table. The determination of position and shape of flexible surface coils using the Kinect camera can be a way to include the CT-based coil μ-map in PET/MRI acquisitions without the need for additional MRI scans. Accuracy and practicability of the method have to be tested in further experiments.

  11. Determination of position and shape of flexible mri surface coils using the Microsoft Kinect for attenuation correction in PET/MRI

    International Nuclear Information System (INIS)

    Frohwein, Lynn; He, Mirco; Buther, Florian; Safers, Klaus

    2015-01-01

    Due to the varying position and shape of flexible MRI RF surface coils, the creation of attenuation maps for these coils is a challenging task. Nevertheless, coil material (metal, plastic, rubber) attenuates the PET signal to a considerable amount. Thus, including a coil μ-map into the human μ-map is essential. In this work, we present a method to determine the position and shape of flexible coils with the help of the Microsoft Kinect depth camera. Phantom PET/MRI (Siemens Biograph mMR) and CT scans (Siemens Biograph mCT) were performed with and without the flexible 32-channel coil equipped with 15 markers visible in CT and Kinect. Prior to the PET/MRI acquisition, Kinect data is acquired of the phantom with the coil on top. The manually extracted marker positions from CT and Kinect are used to non-rigidly transform the template CT according to the Kinect marker positions describing the shape of the coil during PET/MRI acquisition. An appropriate μ-map can then be calculated from the transformed CT dataset. Subsequently, the μ-map is placed in relation to the patient table according to the Kinect-derived marker positions. First results show that the coil shape can be determined with the help of the Kinect camera. The transformation of the template CT dataset according to Kinect marker positions during PET/MRI leads to appropriate results. Furthermore, the position of the coil can also be determined for an accurate placement of the μ-map in relation to the patient table. The determination of position and shape of flexible surface coils using the Kinect camera can be a way to include the CT-based coil μ-map in PET/MRI acquisitions without the need for additional MRI scans. Accuracy and practicability of the method have to be tested in further experiments.

  12. PET/MR in oncology

    DEFF Research Database (Denmark)

    Balyasnikova, Svetlana; Löfgren, Johan; de Nijs, Robin

    2012-01-01

    of the challenges inherent in this new technology, but focus on potential applications for simultaneous PET/MR in the field of oncology. Methods and tracers for use with the PET technology will be familiar to most readers of this journal; thus this paper aims to provide a short and basic introduction to a number...... be applied together with PET increasing the amount of information about the tissues of interest. The potential clinical benefit of applying PET/MR in staging, radiotherapy planning and treatment evaluation in oncology, as well as the research perspectives for the use of PET/MR in the development of new...

  13. Simultaneous PET and MR imaging

    International Nuclear Information System (INIS)

    Yiping Shao; Cherry, Simon R.; Meadors, Ken; Siegel, Stefan; Silverman, Robert W.; Farahani, Keyvan; Marsden, Paul K.

    1997-01-01

    We have developed a prototype PET detector which is compatible with a clinical MRI system to provide simultaneous PET and MR imaging. This single-slice PET system consists of 48 2x2x10mm 3 LSO crystals in a 38 mm diameter ring configuration that can be placed inside the receiver coil of the MRI system, coupled to three multi-channel photomultipliers housed outside the main magnetic field via 4 m long and 2 mm diameter optical fibres. The PET system exhibits 2 mm spatial resolution, 41% energy resolution at 511 keV and 20 ns timing resolution. Simultaneous PET and MR phantom images were successfully acquired. (author)

  14. Limits of Tumor Detectability in Nuclear Medicine and PET

    Directory of Open Access Journals (Sweden)

    Yusuf Emre Erdi

    2012-04-01

    Full Text Available Objective: Nuclear medicine is becoming increasingly important in the early detection of malignancy. The advantage of nuclear medicine over other imaging modalities is the high sensitivity of the gamma camera. Nuclear medicine counting equipment has the capability of detecting levels of radioactivity which exceed background levels by as little as 2.4 to 1. This translates to only a few hundred counts per minute on a regular gamma camera or as few as 3 counts per minute when using coincidence detection on a positron emission tomography (PET camera. Material and Methods: We have experimentally measured the limits of detectability using a set of hollow spheres in a Jaszczak phantom at various tumor-to-background ratios. Imaging modalities for this work were (1 planar, (2 SPECT, (3 PET, and (4 planar camera with coincidence detection capability (MCD. Results: When there is no background (infinite contrast activity present, the detectability of tumors is similar for PET and planar imaging. With the presence of the background activity , PET can detect objects in an order of magnitude smaller in size than that can be seen by conventional planar imaging especially in the typical clinical low (3:1 T/B ratios. The detection capability of the MCD camera lies between a conventional nuclear medicine (planar / SPECT scans and the detection capability of a dedicated PET scanner Conclusion: Among nuclear medicine’s armamentarium, PET is the closest modality to CT or MR imaging in terms of limits of detection. Modern clinical PET scanners have a resolution limit of 4 mm, corresponding to the detection of tumors with a volume of 0.2 ml (7 mm diameter in 5:1 T/B ratio. It is also possible to obtain better resolution limits with dedicated brain and animal scanners. The future holds promise in development of new detector materials, improved camera design, and new reconstruction algorithms which will improve sensitivity, resolution, contrast, and thereby further

  15. Detection of prostate cancer by an FDG-PET cancer screening program: results from a Japanese nationwide survey

    International Nuclear Information System (INIS)

    Minamimoto, Ryogo; Senda, Michio; Jinnouchi, Seishi; Terauchi, Takashi; Inoue, Tomio

    2014-01-01

    The aim of this study was to analyze detection rates and effectiveness of 18 F-fluorodeoxyglucose positron emission tomography (FDG-PET) cancer screening program for prostate cancer in Japan, which is defined as a cancer-screening program for subjects without known cancer. It contains FDG-PET aimed at detection of cancer at an early stage with or without additional screening tests such as prostate-specific antigen (PSA) and magnetic resonance imaging (MRI). A total of 92,255 asymptomatic men underwent the FDG-PET cancer screening program. Of these, 504 cases with findings of possible prostate cancer in any screening method were analyzed. Of the 504 cases, 165 were verified as having prostate cancer. Of these, only 61 cases were detected by FDG-PET, which result in 37.0% relative sensitivity and 32.8% positive predictive value (PPV). The sensitivity of PET/computed tomography (CT) scanner was higher than that of dedicated PET (44.0% vs. 20.4%). However, the sensitivity of FDG-PET was lower than that of PSA and pelvic MRI. FDG-PET did not contribute to improving the sensitivity and PPV when performed as combined screening. PSA should be included in FDG-PET cancer screening programs to screen for prostate cancer

  16. President Roosevelt's 1940 Dedication of the First NCI Building

    Science.gov (United States)

    Watch this video excerpt of the dedication of the National Institute of Health, October 31, 1940. President Roosevelt spoke of the importance of the National Cancer Institute, which would be located in Building 6.

  17. Evaluating the use of dedicated swab for rapid antigen detection ...

    African Journals Online (AJOL)

    Evaluating the use of dedicated swab for rapid antigen detection testing in group a ... African Journal of Clinical and Experimental Microbiology ... Several generations of rapid antigen detection tests (RADTs) have been developed to facilitate ...

  18. Don't Forget About Dedicated Sea Mine Countermeasures

    National Research Council Canada - National Science Library

    Potts, Malcolm H

    2005-01-01

    .... Struggling through the Korean Conflict, the U.S. Navy began a slow improvement of MCM forces leading up to the first Gulf War where experiences led to the conclusion that a well equipped dedicated MCM force structure is essential...

  19. Minimizing Warehouse Space with a Dedicated Storage Policy

    Directory of Open Access Journals (Sweden)

    Andrea Fumi

    2013-07-01

    inevitably be supported by warehouse management system software. On the contrary, the proposed methodology relies upon a dedicated storage policy, which is easily implementable by companies of all sizes without the need for investing in expensive IT tools.

  20. Atlas of PET/MR imaging in oncology

    International Nuclear Information System (INIS)

    Ratib, Osman; Schwaiger, Markus; Beyer, Thomas

    2013-01-01

    Numerous illustrated clinical cases in different oncology domains. Includes digital interactive software matching the cases in the book. Interactive version based on the latest web standard, HTML5, ensuring the widest compatibility. Edited by three international opinion leaders/imaging experts in the field. This new project on PET/MR imaging in oncology includes digital interactive software matching the cases in the book. The interactive version of the atlas is based on the latest web standard, HTML5, ensuring compatibility with any computer operating system as well as a dedicated version for Apple iPad and iPhone. The book opens with an introduction to the principles of hybrid imaging that pays particular attention to PET/MR imaging and standard PET/MR acquisition protocols. A wide range of illustrated clinical case reports are then presented. Each case study includes a short clinical history, findings, and teaching points, followed by illustrations, legends, and comments. The multimedia version of the book includes dynamic movies that allow the reader to browse through series of rotating 3D images (MIP or volume rendered), display blending between PET and MR, and dynamic visualization of 3D image volumes. The movies can be played either continuously or sequentially for better exploration of sets of images. The editors of this state-of-the-art publication are key opinion leaders in the field of multimodality imaging. Professor Osman Ratib (Geneva) and Professor Markus Schwaiger (Munich) were the first in Europe to initiate the clinical adoption of PET/MR imaging. Professor Thomas Beyer (Zurich) is an internationally renowned pioneering physicist in the field of hybrid imaging. Individual clinical cases presented in this book are co-authored by leading international radiologists and nuclear physicians experts in the use of PET and MRI.

  1. FDG PET in the diagnosis of giant cell arteritis

    International Nuclear Information System (INIS)

    Turlakow, A.; Yeung, H.W.D.; Pui, J.; Macapinlac, H.; Liebovitz, E.; Rusch, V.; Goy, A.; Larson, S.M.

    2003-01-01

    Full text: To evaluate the role of PET in the diagnosis of vasculitis. Methods: We report a case of giant cell arteritis diagnosed by FDG-PET in a 75-year-old woman with a fever of unknown origin. The patient presented with a 3 month history of fatigue, fevers, headaches, visual disturbance and jaw claudication. Diagnosis of temporal arteritis was initially excluded because of a normal ESR. CT scan showed an anterior mediastinal mass, suspicious for malignancy. An FDG-PET scan for pre-operative evaluation was acquired 45 minutes after intravenous injection of 10 mCi F18-FDG, on a dedicated PET scanner. Image reconstruction was performed using an iterative algorithm with segmented attenuation correction. The study identified striking localisation of FDG to the entire aorta, left main coronary artery, and subclavian, carotid and common iliac arteries bilaterally (SUV max range 4-4.5 g/ml), suggestive of large vessel arteritis. Subsequent excisional biopsy of the mediastinal mass confirmed giant cell vasculitis of a large muscular artery in thymic tissue. No malignancy was detected. A repeat ESR was 129 mm/hr. The patient was commenced on oral Prednisone, with prompt improvement of symptoms, ESR and anaemia and complete normalisation of the FDG-PET scan within two weeks. This case suggests a potential role of FDG-PET in the non-invasive diagnosis, classification and follow-up of giant cell arteritis, and possibly other vasculitides, so far notoriously difficult to diagnose, relying usually on a constellation of non-specific symptoms, laboratory investigations or invasive pathologic and angiographic means. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  2. Atlas of PET/MR imaging in oncology

    Energy Technology Data Exchange (ETDEWEB)

    Ratib, Osman [University Hospital of Geneva (Switzerland). Nuclear Medicine Division; Schwaiger, Markus [Technische Univ. Muenchen (Germany). Nuklearmedizinische Klinik und Poliklinik; Beyer, Thomas (eds.) [General Hospital Vienna (Austria). Center for Medical Physics and Biomedical Engineering

    2013-08-01

    Numerous illustrated clinical cases in different oncology domains. Includes digital interactive software matching the cases in the book. Interactive version based on the latest web standard, HTML5, ensuring the widest compatibility. Edited by three international opinion leaders/imaging experts in the field. This new project on PET/MR imaging in oncology includes digital interactive software matching the cases in the book. The interactive version of the atlas is based on the latest web standard, HTML5, ensuring compatibility with any computer operating system as well as a dedicated version for Apple iPad and iPhone. The book opens with an introduction to the principles of hybrid imaging that pays particular attention to PET/MR imaging and standard PET/MR acquisition protocols. A wide range of illustrated clinical case reports are then presented. Each case study includes a short clinical history, findings, and teaching points, followed by illustrations, legends, and comments. The multimedia version of the book includes dynamic movies that allow the reader to browse through series of rotating 3D images (MIP or volume rendered), display blending between PET and MR, and dynamic visualization of 3D image volumes. The movies can be played either continuously or sequentially for better exploration of sets of images. The editors of this state-of-the-art publication are key opinion leaders in the field of multimodality imaging. Professor Osman Ratib (Geneva) and Professor Markus Schwaiger (Munich) were the first in Europe to initiate the clinical adoption of PET/MR imaging. Professor Thomas Beyer (Zurich) is an internationally renowned pioneering physicist in the field of hybrid imaging. Individual clinical cases presented in this book are co-authored by leading international radiologists and nuclear physicians experts in the use of PET and MRI.

  3. A new tool fixation for external 3D head tracking using the Polaris Vicra system with the HRRT PET scanner

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Andersen, Flemming; Holm, Søren

    -water studies for up to 75 min (3-8 injections) were registered by the Polaris system in 4 volunteers. The tracking tool was fixed. Scans were divided into subframes based on the registered movements and reconstructed using the 3D-OSEM PSF method. The reconstructed subframes were repositioned to a reference......Objectives: The Polaris Vicra system (Northern Digital Inc.) is used for external 3D head registration with the Siemens HRRT brain PET. Our new tool fixation using a standard bandaid with a velcro-strap implies an improved frame repositioning. Methods: Head movements during serial PET 15O...... position and pairwise similarity of subframes was evaluated before and after the repositioning. Results: Registered movements during scans were less than 4.3mm with. Images were compared before/after motion correction. Conclusions: Our new velcro band-aid fixation is suitable for clinical use: easy to use...

  4. Automated calculation of myocardial external efficiency from a single 11C-acetate PET/CT scan

    DEFF Research Database (Denmark)

    Harms, Hans; Tolbod, Lars Poulsen; Hansson, Nils Henrik

    of this study was to develop and validate an automated method of calculating MEE from a single dynamic 11C-acetate PETscan. Methods: 21 subjects underwent a dynamic 27 min 11C-acetate PETscan on a Siemens Biograph TruePoint 64 PET/CTscanner. Using cluster analysis, the LV-aortic time-activity curve (TACLV......). Conclusion: Myocardial efficiencycanbe derived directly andautomatically froma single dynamic 11C-acetate PET scan. This eliminates the need for a separate CMR scan and eliminates any potential errors due to different loading conditions between CMR and PETscans.......Background: Dynamic PETwith 11C-acetate can be used to assess myocardial oxygen use which in turn is usedto calculate myocardial external efficiency (MEE), anearly marker of heart failure. MEE is defined as the ratio of total work (TW) and total energy use (TE). Calculation of TW and TE requires...

  5. Performance evaluation of Siemens E.CAM(R) SPECT system at Korle-Bu Teaching Hospital (Ghana)

    International Nuclear Information System (INIS)

    Sosu, E.K.; Hasford, F.; Amuasi, J.H.

    2011-01-01

    Performance evaluation tests on Siemens e.cam(R) Signature Series Single Photon Emission Computed Tomography (SPECT)System at Korle-Bu Teaching Hospital (Ghana) were conducted for compliance with Manufacturer's specifications and user's requirements. The tests were performed according to National Electrical Manufacturer's Association protocols, and different measuring instruments and phantoms containing 99m-Tc were used. Extrinsic uniformity, system energy resolution, system spatial resolution (without scattering), detector shield leakage and system planar sensitivity were evaluated. The system energy resolution measured was 9.38 % as against manufacturer's specification of ≤ 9.9 %, Planar sensitivity value measured was 232.92 c/min/mCi while manufacturers' specification was 202 c/min/mCi, and detector shield leakage values measured were 0.001 %, 0.002 % and 0.025 % against an accepted value of < 1 %. The performance evaluation confirmed that the system met requirements for clinical nuclear medicine imaging, and the values could be used as database for future quality control measurements. (au)

  6. Thermalhydraulic assessment of the Pickering NGS 'B' feed and bleed system for the hot boiler chemical clean (Siemens Process)

    International Nuclear Information System (INIS)

    Lorencez, Carlos M.

    2000-01-01

    The Hot Boiler Chemical Clean (HBCC) process from Siemens, to be used in PNGS, requires that the Heat Transport System (HTS) temperature be maintained in the range 160 to 170 o C for several days. To achieve these thermalhydraulic condition, the core decay power and the pump power of the main circulating pumps in a 3-3 configuration are employed to warm up the HTS from approximately 38 o C to 170 o C. At this point, high Bleed bias is applied to the signal of the HTS pressure controller to provide high Feed and Bleed flows, which are used to control the HTS temperature by means of the Bleed Cooler. To address any concern posed by these infrequently used HTS thermalhydraulic conditions, a detailed thermalhydraulic model of the Feed and Bleed System, that also includes the Gland Supply, Gland Return and Purification systems, was developed for the TUF code to determine the suitability of the Feed and Bleed System to conduct the HBCC. The model was then used to estimate the parameters such as Feed and Bleed flows, valve openings, pressure and temperature distributions throughout the Feed and Bleed System required for the application of HBCC. (author)

  7. Photo neutron dose equivalent rate in 15 MV X-ray beam from a Siemens Primus Linac

    Directory of Open Access Journals (Sweden)

    A Ghasemi

    2015-01-01

    Full Text Available Fast and thermal neutron fluence rates from a 15 MV X-ray beams of a Siemens Primus Linac were measured using bare and moderated BF 3 proportional counter inside the treatment room at different locations. Fluence rate values were converted to dose equivalent rate (DER utilizing conversion factors of American Association of Physicist in Medicine′s (AAPM report number 19. For thermal neutrons, maximum and minimum DERs were 3.46 × 10 -6 (3 m from isocenter in +Y direction, 0 × 0 field size and 8.36 × 10 -8 Sv/min (in maze, 40 × 40 field size, respectively. For fast neutrons, maximum DERs using 9" and 3" moderators were 1.6 × 10 -5 and 1.74 × 10 -5 Sv/min (2 m from isocenter in +Y direction, 0 × 0 field size, respectively. By changing the field size, the variation in thermal neutron DER was more than the fast neutron DER and the changes in fast neutron DER were not significant in the bunker except inside the radiation field. This study showed that at all points and distances, by decreasing field size of the beam, thermal and fast neutron DER increases and the number of thermal neutrons is more than fast neutrons.

  8. Deposition reactors for solar grade silicon: A comparative thermal analysis of a Siemens reactor and a fluidized bed reactor

    Science.gov (United States)

    Ramos, A.; Filtvedt, W. O.; Lindholm, D.; Ramachandran, P. A.; Rodríguez, A.; del Cañizo, C.

    2015-12-01

    Polysilicon production costs contribute approximately to 25-33% of the overall cost of the solar panels and a similar fraction of the total energy invested in their fabrication. Understanding the energy losses and the behaviour of process temperature is an essential requirement as one moves forward to design and build large scale polysilicon manufacturing plants. In this paper we present thermal models for two processes for poly production, viz., the Siemens process using trichlorosilane (TCS) as precursor and the fluid bed process using silane (monosilane, MS). We validate the models with some experimental measurements on prototype laboratory reactors relating the temperature profiles to product quality. A model sensitivity analysis is also performed, and the effects of some key parameters such as reactor wall emissivity and gas distributor temperature, on temperature distribution and product quality are examined. The information presented in this paper is useful for further understanding of the strengths and weaknesses of both deposition technologies, and will help in optimal temperature profiling of these systems aiming at lowering production costs without compromising the solar cell quality.

  9. New cardiac cameras: single-photon emission CT and PET.

    Science.gov (United States)

    Slomka, Piotr J; Berman, Daniel S; Germano, Guido

    2014-07-01

    Nuclear cardiology instrumentation has evolved significantly in the recent years. Concerns about radiation dose and long acquisition times have propelled developments of dedicated high-efficiency cardiac SPECT scanners. Novel collimator designs, such as multipinhole or locally focusing collimators arranged in geometries that are optimized for cardiac imaging, have been implemented to enhance photon-detection sensitivity. Some of these new SPECT scanners use solid-state photon detectors instead of photomultipliers to improve image quality and to reduce the scanner footprint. These new SPECT devices allow dramatic up to 7-fold reduction in acquisition times or similar reduction in radiation dose. In addition, new hardware for photon attenuation correction allowing ultralow radiation doses has been offered by some vendors. To mitigate photon attenuation artifacts for the new SPECT scanners not equipped with attenuation correction hardware, 2-position (upright-supine or prone-supine) imaging has been proposed. PET hardware developments have been primarily driven by the requirements of oncologic imaging, but cardiac imaging can benefit from improved PET image quality and improved sensitivity of 3D systems. The time-of-flight reconstruction combined with resolution recovery techniques is now implemented by all major PET vendors. These new methods improve image contrast and image resolution and reduce image noise. High-sensitivity 3D PET without interplane septa allows reduced radiation dose for cardiac perfusion imaging. Simultaneous PET/MR hybrid system has been developed. Solid-state PET detectors with avalanche photodiodes or digital silicon photomultipliers have been introduced, and they offer improved imaging characteristics and reduced sensitivity to electromagnetic MR fields. Higher maximum count rate of the new PET detectors allows routine first-pass Rb-82 imaging, with 3D PET acquisition enabling clinical utilization of dynamic imaging with myocardial flow

  10. PET-CT imaging fusion in the assessment of head and neck carcinoma

    International Nuclear Information System (INIS)

    Santos, Denise Takehana dos; Chojniak, Rubens; Lima, Eduardo Nobrega Pereira; Cavalcanti, Marcelo Gusmao Paraiso

    2006-01-01

    Objective: The authors have established a methodological approach to evaluate head and neck squamous cell carcinoma aiming at identifying and distinguishing high metabolic activity inside the lesion, combining in a single examination, functional, metabolic and morphological data simultaneously acquired by means of different non-dedicated positron emission tomography (PET)-computed tomography (CT) device. Materials and Methods: The study population included 17 patients with head and neck squamous cell carcinoma submitted to a non-dedicated 18 F-FDG-PET imaging at Department of Diagnostic Imaging of Hospital do Cancer, Sao Paulo, SP, Brazil. CT and 18 F-FDG-PET images were simultaneously acquired in a non-dedicated device. The original data were transferred to an independent workstation by means of the Entegra 2 NT software to generate PET-CT imaging fusion. Results: The findings were defined as positive in the presence of a well defined focal area of increased radiopharmaceutical uptake in regions not related with the normal biodistribution of the tracer. Conclusion: The fusion of simultaneously acquired images in a single examination ( 18 F-FDGPET and CT) has allowed the topographic-metabolic mapping of the lesion as well as the localization of high metabolic activity areas inside the tumor, indicating recidivation or metastasis and widening the array of alternatives for radiotherapy or surgical planning. (author)

  11. PET and PET/CT in malignant melanoma; PET y PET/CT en melanoma maligno

    Energy Technology Data Exchange (ETDEWEB)

    Garcia O, J R [Nuclear Medicine and Molecular Imaging PET/CT, Centro Medico ABC, Mexico D.F. (Mexico)

    2007-07-01

    The advantages that it has the PET/CT are: 1. It diminishes mainly positive false lesions. It identifies physiologic accumulate places. 2. It diminishes in smaller grade false negative. Small injuries. Injuries with low grade concentration. Injure on intense activity areas. 3. Precise anatomical localization of accumulate places. 4. Reduction of the acquisition time. (Author)

  12. I Love Petting Zoos!

    Centers for Disease Control (CDC) Podcasts

    2010-03-23

    This Kidtastics podcast helps children learn about how to stay safe and healthy when visiting petting zoos and other animal exhibits.  Created: 3/23/2010 by Centers for Disease Control and Prevention (CDC).   Date Released: 3/23/2010.

  13. PET's indsats under lup

    DEFF Research Database (Denmark)

    Hansen, Peer Henrik

    2006-01-01

    En undersøgelseskommission nedsat i 1999. Fem medlemmer skal undersøge PET's efterretningsvirksomhed i forhold til politiske partier, faglige konflikter og politisk ideologiske bevægelser i Danmark under den kolde krig. Kommissionens rapport forventes færdig næste år. Udgivelsesdato: 2. juli 2006...

  14. Choosing a Pet

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    THE capital boasts countless markets of all kinds,but some of its insect,bird and pet markets immortalize Beijing culture and folkloric traditions.Don’t miss it! The Huasheng Tianqiao Market,south of the famous Panjiayuan Antique Market, was moved a few years ago and rebuilt in the

  15. PET CT and lymphomas

    International Nuclear Information System (INIS)

    Castro, R.

    2012-01-01

    This presentation is about Tc and lymphomas. Classification and clinical cases of various cancer such as gastro duodenal or ulcer, mama, medullary, lymph and neck, leukemia, nodular sclerosis. Metabolic information, anatomical nature of lymphoma and its clinical presentation determine the extent that PET should be used in the patient.

  16. Effects of ferumoxytol on quantitative PET measurements in simultaneous PET/MR whole-body imaging: a pilot study in a baboon model.

    Science.gov (United States)

    Borra, Ronald Jh; Cho, Hoon-Sung; Bowen, Spencer L; Attenberger, Ulrike; Arabasz, Grae; Catana, Ciprian; Josephson, Lee; Rosen, Bruce R; Guimaraes, Alexander R; Hooker, Jacob M

    2015-12-01

    Simultaneous PET/MR imaging depends on MR-derived attenuation maps (mu-maps) for accurate attenuation correction of PET data. Currently, these maps are derived from gradient-echo-based MR sequences, which are sensitive to susceptibility changes. Iron oxide magnetic nanoparticles have been used in the measurement of blood volume, tumor microvasculature, tumor-associated macrophages, and characterizing lymph nodes. Our aim in this study was to assess whether the susceptibility effects associated with iron oxide nanoparticles can potentially affect measured (18)F-FDG PET standardized uptake values (SUV) through effects on MR-derived attenuation maps. The study protocol was approved by the Institutional Animal Care and Use Committee. Using a Siemens Biograph mMR PET/MR scanner, we evaluated the effects of increasing concentrations of ferumoxytol and ferumoxytol aggregates on MR-derived mu-maps using an agarose phantom. In addition, we performed a baboon experiment evaluating the effects of a single i.v. ferumoxytol dose (10 mg/kg) on the liver, spleen, and pancreas (18)F-FDG SUV at baseline (ferumoxytol-naïve), within the first hour and at 1, 3, 5, and 11 weeks. Phantom experiments showed mu-map artifacts starting at ferumoxytol aggregate concentrations of 10 to 20 mg/kg. The in vivo baboon data demonstrated a 53% decrease of observed (18)F-FDG SUV compared to baseline within the first hour in the liver, persisting at least 11 weeks. A single ferumoxytol dose can affect measured SUV for at least 3 months, which should be taken into account when administrating ferumoxytol in patients needing sequential PET/MR scans. Advances in knowledge 1. Ferumoxytol aggregates, but not ferumoxytol alone, produce significant artifacts in MR-derived attenuation correction maps at approximate clinical dose levels of 10 mg/kg. 2. When performing simultaneous whole-body (18)F-FDG PET/MR, a single dose of ferumoxytol can result in observed SUV decreases up to 53%, depending on the

  17. Poster - 01: LabPET II Pixelated APD-Based PET Scanner for High-Resolution Preclinical Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lecomte, Roger; Arpin, Louis; Beaudoin, Jean-François; Bergeron, Mélanie; Bouchard, Jonathan; Bouziri, Haithem; Cadorette, Jules; Gaudin, Émilie; Jürgensen, Nadia; Koua, Konin Calliste; Trépanier, Pierre-Yves Lauzier; Leroux, Jean-Daniel; Loignon-Houle, Francis; Njejimana, Larissa; Paillé, Maxime; Paulin, Caroline; Pepin, Catherine; Pratte, Jean-François; Samson, Arnaud; Thibaudeau, Christian [Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, Université de Sherbrooke, Université de Sherbrooke, 3IT, Université de Sherbrooke, Novalgo Inc., Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, 3IT, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, 3IT, Université de Sherbrooke (Canada); and others

    2016-08-15

    Purpose: LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using truly pixelated detectors and highly integrated parallel front-end processing electronics. Methods: The basic element uses a 4×8 array of 1.12×1.12 mm{sup 2} Lu{sub 1.9}Y{sub 0.1}SiO{sub 5}:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4×8 pixelated monolithic APD array mounted on a ceramic carrier. Four detector arrays are mounted on a daughter board carrying two flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was implemented in silico by encoding time and energy information using a dual-threshold Time-over-Threshold (ToT) scheme. The self-contained 128-channel detector module was designed as a generic component for ultra-high resolution PET imaging of small to medium-size animals. Results: Energy and timing performance were optimized by carefully setting ToT thresholds to minimize the noise/slope ratio. ToT spectra clearly show resolved 511 keV photopeak and Compton edge with ToT resolution well below 10%. After correction for nonlinear ToT response, energy resolution is typically 24±2% FWHM. Coincidence time resolution between opposing 128-channel modules is below 4 ns FWHM. Initial imaging results demonstrate that 0.8 mm hot spots of a Derenzo phantom can be resolved. Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed and shown to achieve a spatial resolution approaching the physical limit of PET. Future plans are to integrate a small-bore dedicated mouse version of the scanner within a PET/CT platform.

  18. SU-E-J-86: Lobar Lung Function Quantification by PET Galligas and CT Ventilation Imaging in Lung Cancer Patients

    International Nuclear Information System (INIS)

    Eslick, E; Kipritidis, J; Keall, P; Bailey, D; Bailey, E

    2014-01-01

    Purpose: The purpose of this study was to quantify the lobar lung function using the novel PET Galligas ([68Ga]-carbon nanoparticle) ventilation imaging and the investigational CT ventilation imaging in lung cancer patients pre-treatment. Methods: We present results on our first three lung cancer patients (2 male, mean age 78 years) as part of an ongoing ethics approved study. For each patient a PET Galligas ventilation (PET-V) image and a pair of breath hold CT images (end-exhale and end-inhale tidal volumes) were acquired using a Siemens Biograph PET CT. CT-ventilation (CT-V) images were created from the pair of CT images using deformable image registration (DIR) algorithms and the Hounsfield Unit (HU) ventilation metric. A comparison of ventilation quantification from each modality was done on the lobar level and the voxel level. A Bland-Altman plot was used to assess the difference in mean percentage contribution of each lobe to the total lung function between the two modalities. For each patient, a voxel-wise Spearmans correlation was calculated for the whole lungs between the two modalities. Results: The Bland-Altman plot demonstrated strong agreement between PET-V and CT-V for assessment of lobar function (r=0.99, p<0.001; range mean difference: −5.5 to 3.0). The correlation between PET-V and CT-V at the voxel level was moderate(r=0.60, p<0.001). Conclusion: This preliminary study on the three patients data sets demonstrated strong agreement between PET and CT ventilation imaging for the assessment of pre-treatment lung function at the lobar level. Agreement was only moderate at the level of voxel correlations. These results indicate that CT ventilation imaging has potential for assessing pre-treatment lobar lung function in lung cancer patients

  19. Whole-Body Single-Bed Time-of-Flight RPC-PET: Simulation of Axial and Planar Sensitivities With NEMA and Anthropomorphic Phantoms

    Science.gov (United States)

    Crespo, Paulo; Reis, João; Couceiro, Miguel; Blanco, Alberto; Ferreira, Nuno C.; Marques, Rui Ferreira; Martins, Paulo; Fonte, Paulo

    2012-06-01

    A single-bed, whole-body positron emission tomograph based on resistive plate chambers has been proposed (RPC-PET). An RPC-PET system with an axial field-of-view (AFOV) of 2.4 m has been shown in simulation to have higher system sensitivity using the NEMA NU2-1994 protocol than commercial PET scanners. However, that protocol does not correlate directly with lesion detectability. The latter is better correlated with the planar (slice) sensitivity, obtained with a NEMA NU2-2001 line-source phantom. After validation with published data for the GE Advance, Siemens TruePoint and TrueV, we study by simulation their axial sensitivity profiles, comparing results with RPC-PET. Planar sensitivities indicate that RPC-PET is expected to outperform 16-cm (22-cm) AFOV scanners by a factor 5.8 (3.0) for 70-cm-long scans. For 1.5-m scans (head to mid-legs), the sensitivity gain increases to 11.7 (6.7). Yet, PET systems with large AFOV provide larger coverage but also larger attenuation in the object. We studied these competing effects with both spherical- and line-sources immersed in a 27-cm-diameter water cylinder. For 1.5-m-long scans, the planar sensitivity drops one order of magnitude in all scanners, with RPC-PET outperforming 16-cm (22-cm) AFOV scanners by a factor 9.2 (5.3) without considering the TOF benefit. A gain in the effective sensitivity is expected with TOF iterative reconstruction. Finally, object scatter in an anthropomorphic phantom is similar for RPC-PET and modern, scintillator-based scanners, although RPC-PET benefits further if its TOF information is utilized to exclude scatter events occurring outside the anthropomorphic phantom.

  20. Three steam generator replacement projects in 1995: Consortium Siemens Framatome is well prepared to contribute its experience to the SGR at the Krsko NPP

    International Nuclear Information System (INIS)

    Holz, R.; Clavier, G.

    1996-01-01

    Since the companies Siemens AG and Framatome S.A. joined their experience and efforts in the field of steam generators replacements and formed a consortium in 1991, the following projects were performed in 1995: Ringhals 3, Tihange 3 and Asco 2. Further projects will follow in 1996, i.e., Doel 4 and Asco 2. Currently, this European consortium is bidding for the contract to replace the steam generators at the Krsko NPP and hopes to be awarded in 1996. An overview of the way the Consortium Siemens and Framatome approaches SG replacement projects is given based on the projects performed in 1995. Various aspects of project planning, management, licensing, personnel qualification and techniques used on site will be discussed. (author)

  1. PET or PET-CT with cancer screening

    International Nuclear Information System (INIS)

    Wang Taisong; Zhao Jinhua; Song Jianhua

    2007-01-01

    At present, cancer screening remains a lot of debate in contemporary medical practice. Many constitutes have done a lot of experiments in cancer screening. The same version is that recommendations and decisions regarding cancer screening should be based on reliable data, not self- approbation. Now, some institutes advocate 18 F-FDG PET or 18 F-FDG PET-CT for cancer screening, here, discussed status quo, potential financial, radiation safety and statistical data in 18 F-FDG PET or 18 F-FDG PET- CT cancer screening. (authors)

  2. Simultaneous whole-body 18F-FDG PET-MRI in primary staging of breast cancer: A pilot study

    International Nuclear Information System (INIS)

    Taneja, Sangeeta; Jena, Amarnath; Goel, Reema; Sarin, Ramesh; Kaul, Sumaid

    2014-01-01

    Highlights: • Initial staging of breast cancer important in treatment planning and prognostication. • We assessed role of simultaneous 18 F-FDG PET-MRI in initial staging of breast cancer. • Primary, nodes and metastases on PET, MRI and PET-MRI for count and diagnostic confidence. • High diagnostic accuracy and confidence in detecting index and satellite lesions. • Comprehensive nodal and distant metastases staging with altered management (12 cases). - Abstract: Purpose: Accurate initial staging in breast carcinoma is important for treatment planning and for establishing the likely prognosis. The purpose of this study was to assess the utility of whole body simultaneous 18 F-FDG PET-MRI in initial staging of breast carcinoma. Methods: 36 patients with histologically confirmed invasive ductal carcinoma underwent simultaneous whole body 18 F-FDG PET-MRI on integrated 3 T PET-MR scanner (Siemens Biograph mMR) for primary staging. Primary lesion, nodes and metastases were evaluated on PET, MRI and PET-MRI for lesion count and diagnostic confidence (DC). Kappa co relation analysis was done to assess agreement between the satellite, nodal and metastatic lesions detected by PET and MRI. Histopathology, clinical/imaging follow-up served as the reference standard. Results: 36 patients with 37 histopathologically proven index breast cancer were retrospectively studied. Of 36 patients, 25 patients underwent surgery and 11 patients received systemic therapy. All index cancers were seen on PET and MR. Fused PET-MRI showed highest diagnostic confidence score of 5 as compared to PET (median 4; range 3–5) and MRI (median 4; range 4–5) alone. 2/36 (5.5%) patients were detected to have unsuspected contralateral synchronous cancer. 47 satellite lesions were detected on DCE MRI of which 23 were FDG avid with multifocality and multicentricity in 21 (58%) patients. Kappa co relation analysis revealed fair agreement for satellite lesion detection by the two modalities (κ

  3. Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus

    Directory of Open Access Journals (Sweden)

    Jennifer L. Johns

    2018-02-01

    Full Text Available Clinical pathology testing of rodents is often challenging due to insufficient sample volume. One solution in clinical veterinary and exploratory research environments is dilution of samples prior to analysis. However, published information on the impact of preanalytical sample dilution on rodent biochemical data is incomplete. The objective of this study was to evaluate the effects of preanalytical sample dilution on biochemical analysis of mouse and rat serum samples utilizing the Siemens Dimension Xpand Plus. Rats were obtained from end of study research projects. Mice were obtained from sentinel testing programs. For both, whole blood was collected via terminal cardiocentesis into empty tubes and serum was harvested. Biochemical parameters were measured on fresh and thawed frozen samples run straight and at dilution factors 2–10. Dilutions were performed manually, utilizing either ultrapure water or enzyme diluent per manufacturer recommendations. All diluted samples were generated directly from the undiluted sample. Preanalytical dilution caused clinically unacceptable bias in most analytes at dilution factors four and above. Dilution-induced bias in total calcium, creatinine, total bilirubin, and uric acid was considered unacceptable with any degree of dilution, based on the more conservative of two definitions of acceptability. Dilution often caused electrolyte values to fall below assay range precluding evaluation of bias. Dilution-induced bias occurred in most biochemical parameters to varying degrees and may render dilution unacceptable in the exploratory research and clinical veterinary environments. Additionally, differences between results obtained at different dilution factors may confound statistical comparisons in research settings. Comparison of data obtained at a single dilution factor is highly recommended.

  4. Comprehensive approach to energy and environment in the Eco Care Program for design, engineering and operation of Siemens Industry Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Wegener, D. (Siemens AG, Erlangen (Germany)); Finkbeiner, M. (Technische Univ. Berlin (TUB), Systemumwelttechnik (SUT), Berlin (Germany)); Geiger, D. (Siemens AG, Munich (Germany)); Olsen, S.I. (Danish Technical Univ. (DTU), Management Engineering, Lyngby (Denmark)); Walachowicz, F. (Siemens AG, Berlin (Germany))

    2009-09-15

    This paper intends to describe the outline of the Eco Care Program (ECP) at the Siemens-Division Industry Solutions and its implementation. ECP aims to embrace and to coordinate main activities within the product lifecycle management (PLM) process considering both economic targets in terms of overall lifecycle costs as well as energy efficiency and other important environmental issues in the innovation management for industrial solutions. ECP consists of adapted methods for assessing the environmental and financial impacts of industrial solutions (plants, processes, single technologies or even services) and tools which helps to derive reliable assessment results. Life Cycle Assessment (LCA) is a suitable method for assessing environmental impacts of products and solutions over their entire lifecycle focusing on those lifecycle phases which may contribute significantly to environmental burdens or benefits. To meet these requirements the main challenge is to simplify the assessment methodology as far as reliability and accuracy of results is preserved. To present results in both dimensions of economical performance and environmental impact the paper introduces the concept of the 'eco care matrix' (ECM). Environmental sound industrial solutions have advantages in both 'eco' dimensions (eco-nomical + eco-logical). The analytical approach presented is further on implemented in two complementary and independent industrial application fields: in order to exemplify usability of the approach in quite complex process technology different hot metal producing technologies (blast furnace route vs. smelting reduction routes COREX / FINEX). The second pilot application is targeted on the assessment of infrastructure solutions especially focusing on the comparison of environmental and financial effects of different technologies and payment schemes of electronic city tolling systems for London and Copenhagen. Experienced results derived from these two pilot

  5. Read the Label First: Protect Your Pets

    Science.gov (United States)

    Learn about the importance of reading pet products labels before purchasing and using any product to insure the safety of your pets. Find tips for ways to reduce the changes of pets accessing potentially dangerous products.

  6. Cyclotron/PET project in Uruguay

    International Nuclear Information System (INIS)

    Engler, H.

    2006-01-01

    The Positron Computed Tomography (PET) is a tri dimensional image technique which shows biochemical information. PET is used in neurology and cardiology diseases. The National Center Cyclotron PET has been found to research, development and health science applications.

  7. Dedication increases productivity: an analysis of the implementation of a dedicated medical team in the emergency department.

    Science.gov (United States)

    Ramos, Pedro; Paiva, José Artur

    2017-12-01

    In several European countries, emergency departments (EDs) now employ a dedicated team of full-time emergency medicine (EM) physicians, with a distinct leadership and bed-side emergency training, in all similar to other hospital departments. In Portugal, however, there are still two very different models for staffing EDs: a classic model, where EDs are mostly staffed with young inexperienced physicians from different medical departments who take turns in the ED in 12-h shifts and a dedicated model, recently implemented in some hospitals, where the ED is staffed by a team of doctors with specific medical competencies in emergency medicine that work full-time in the ED. Our study assesses the effect of an intervention in a large academic hospital ED in Portugal in 2002, and it is the first to test the hypothesis that implementing a dedicated team of doctors with EM expertise increases the productivity and reduces costs in the ED, maintaining the quality of care provided to patients. A pre-post design was used for comparing the change on the organisational model of delivering care in our medical ED. All emergency medical admissions were tracked in 2002 (classic model with 12-h shift in the ED) and 2005/2006 (dedicated team with full-time EM physicians), and productivity, costs with medical human resources and quality of care measures were compared. We found that medical productivity (number of patients treated per hour of medical work) increased dramatically after the creation of the dedicated team (X 2 KW = 31.135; N = 36; p work reduced both in regular hours and overtime. Moreover, hospitalisation rates decreased and the length of stay in the ED increased significantly after the creation of the dedicated team. Implementing a dedicated team of doctors increased the medical productivity and reduced costs in our ED. Our findings have straightforward implication for Portuguese policymakers aiming at reducing hospital costs while coping with increased ED demand.

  8. Simultaneous trimodal MR-PET-EEG imaging for the investigation of resting state networks in humans

    Energy Technology Data Exchange (ETDEWEB)

    Neuner, Irene [RWTH Aachen (Germany); Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich GmbH (Germany); Mauler, Joerg; Arrubla, Jorge; Kops, Elena Rota; Tellmann, Lutz; Scheins, Jurgen; Herzog, Hans [Institute of Neuroscience and Medicine - 4, Forschungszentrum Juelich GmbH (Germany); Langen, Karl Josef; Shah, Jon [RWTH Aachen (Germany)

    2015-05-18

    Glucose is the principal source of energy for the brain and its relationship to neuronal activity are poorly understood. The human brain uses 80% of its energy for ongoing neural activity that occurs in isolation from any particular stimulus. A promising tool for the investigation of glucose metabolism and its relationship to neuronal activity is simultaneous trimodal MR-PET-EEG data imaging. We here demonstrate the first in vivo human trimodal data at 3T. In one session MR, FDG-PET and EEG data were recorded simultaneously at a 3T hybrid MR-BrainPET scanner (Siemens, Germany) equipped with a 32 channel MR-compatible EEG system (Brain Products, Germany) in 11 healthy volunteers (11 males, mean age: 25.2 years SD: 1.2). MR and EEG data acquisition MP-RAGE (TR = 2250 ms, TE= 3.03 ms, 176 sagittal slices. 1 mm, GRAPPA factor 2. MR-based attenuation correction of PET data via UTE: flip angle=15. Two different echo times TE1=0.07 and TE2=2.46 ms, TR=200 ms. EPI sequence (TR: 2.2 s, TE: 30 ms, FOV: 200 mm, 165 volumes, The subjects were requested to close their eyes and relax EEG data were recorded using a 32-channel MR compatible EEG system. App. 200 MBq/μmol FDG were injected, data were acquired in list mode and iteratively reconstructed with all necessary corrections into 153 slices with 256 x 256 voxels sized 1.25 mm{sup 3}. The trimodal approach, recording PET data, MR data and EEG data simultaneously was successful. The high neuronal activity of the structures within the default mode network occurs on the basis of a high glucose consumption rate within the default node network. The activity of the default mode is not tied to a special EEG frequency band.

  9. 18F-FDG PET demonstrates previously unvisualised bony metastases in a lung cancer patient

    International Nuclear Information System (INIS)

    Bradley, J.; Rowe, C.; Scott, A.M.

    2002-01-01

    Full text: A 59-year-old male, presented to his local doctor with the trivial complaint of a persistent dry cough. On clinical examination he was found to have an enlarged right supraclavicular lymph node. He was investigated with chest X-ray, Computerised Tomography (CT) and Fine Needle Aspiration Cytology (FNAC) of the palpable node CT showed a right lung mass, bulky hilar, mediastinal, supraclavicular and cervical lymph nodes FNAC was inconclusive due to an insufficient tissue sample, but suggestive of non-Hodgkin's Lymphoma. Hence excisional node biopsy was required which revealed non-small cell lung cancer (NSCLC). Subsequent CT scans of the abdomen and pelvis for staging revealed no distant involvement. Therefore radical radiotherapy was planned to treat the locally advanced disease. Prior to treatment a Positron Emission Tomography (PET) scan was organised by his specialist as a baseline study to monitor therapy progress. Non-Attenuation corrected images of the chest, abdomen and pelvis were obtained 40 minutes post administration of 394 MBq 18 F-FDG, on a Siemens 951/3IR PET scanner. The images were reconstructed using both Filtered Back Projection (FBP) and Ordered Subsets-Expectation Maximization (OSEM) algorithms. The images revealed extensive metastases particularly in the spine and pelvis, besides the known locally advanced thoracic disease A 99m Tc MDP bone scan and plain film radiographs aimed at confirming bony metastases were negative, even though the bone scan noted a slight focus in the right fourth rib. The appearance suggested trauma, but a solitary bone metastasis could not be ruled out MRI of the spine confirmed the PET scan findings. Mr RD was to have curative radical radiotherapy, but after the PET results, it was decided to treat him palliatively. The value of 18 F-FDG PET in staging some cancers such as NSCLC is widely accepted, in this case it was pivotal in altering the patient's management. Copyright (2002) The Australian and New

  10. Simultaneous trimodal MR-PET-EEG imaging for the investigation of resting state networks in humans

    International Nuclear Information System (INIS)

    Neuner, Irene; Mauler, Joerg; Arrubla, Jorge; Kops, Elena Rota; Tellmann, Lutz; Scheins, Jurgen; Herzog, Hans; Langen, Karl Josef; Shah, Jon

    2015-01-01

    Glucose is the principal source of energy for the brain and its relationship to neuronal activity are poorly understood. The human brain uses 80% of its energy for ongoing neural activity that occurs in isolation from any particular stimulus. A promising tool for the investigation of glucose metabolism and its relationship to neuronal activity is simultaneous trimodal MR-PET-EEG data imaging. We here demonstrate the first in vivo human trimodal data at 3T. In one session MR, FDG-PET and EEG data were recorded simultaneously at a 3T hybrid MR-BrainPET scanner (Siemens, Germany) equipped with a 32 channel MR-compatible EEG system (Brain Products, Germany) in 11 healthy volunteers (11 males, mean age: 25.2 years SD: 1.2). MR and EEG data acquisition MP-RAGE (TR = 2250 ms, TE= 3.03 ms, 176 sagittal slices. 1 mm, GRAPPA factor 2. MR-based attenuation correction of PET data via UTE: flip angle=15. Two different echo times TE1=0.07 and TE2=2.46 ms, TR=200 ms. EPI sequence (TR: 2.2 s, TE: 30 ms, FOV: 200 mm, 165 volumes, The subjects were requested to close their eyes and relax EEG data were recorded using a 32-channel MR compatible EEG system. App. 200 MBq/μmol FDG were injected, data were acquired in list mode and iteratively reconstructed with all necessary corrections into 153 slices with 256 x 256 voxels sized 1.25 mm 3 . The trimodal approach, recording PET data, MR data and EEG data simultaneously was successful. The high neuronal activity of the structures within the default mode network occurs on the basis of a high glucose consumption rate within the default node network. The activity of the default mode is not tied to a special EEG frequency band.

  11. Development of a Measurement and Control System for a 40l/h Helium Liquefier based on Siemens PLC S7-300

    Science.gov (United States)

    Li, J.; Liu, L. Q.; Xu, X. D.; Liu, T.; Li, Q.; Hu, Z. J.; Wang, B. M.; Xiong, L. Y.; Dong, B.; Yan, T.

    A 40l/h Helium Liquefier has been commissioned by the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. A measurement and control system based on Siemens PLC S7-300 for this Helium Liquefier is developed. Proper sensors are selected, for example, three types of transmitters are adopted respectively according to detailed temperature measurement requirements. Siemens S7-300 PLC CPU315-2PN/DP operates as a master station and three sets of ET200 M DP remote expand I/O operate asslave stations. Profibus-DP field communication is used between the master station and the slave stations. The upper computer HMI(Human Machine Interface) is compiled using Siemens configuration software WinCC V7.0. The upper computer communicates with PLC by means of industrial Ethernet. A specific control logic for this Helium Liquefier is developed. The control of the suction and discharge pressures of the compressor and the control of the turbo-expanders loop are being discussed in this paper. Following the commissioning phase, the outlet temperature of the second stage turbine has reached 8.6K and the temperature before the throttle valve has reached 13.1K.

  12. Measurement and control system for cryogenic helium gas bearing turbo-expander experimental platform based on Siemens PLC S7-300

    Science.gov (United States)

    Li, J.; Xiong, L. Y.; Peng, N.; Dong, B.; Wang, P.; Liu, L. Q.

    2014-01-01

    An experimental platform for cryogenic Helium gas bearing turbo-expanders is established at the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. This turbo-expander experimental platform is designed for performance testing and experimental research on Helium turbo-expanders with different sizes from the liquid hydrogen temperature to the room temperature region. A measurement and control system based on Siemens PLC S7-300 for this turbo-expander experimental platform is developed. Proper sensors are selected to measure such parameters as temperature, pressure, rotation speed and air flow rate. All the collected data to be processed are transformed and transmitted to S7-300 CPU. Siemens S7-300 series PLC CPU315-2PN/DP is as master station and two sets of ET200M DP remote expand I/O is as slave station. Profibus-DP field communication is established between master station and slave stations. The upper computer Human Machine Interface (HMI) is compiled using Siemens configuration software WinCC V6.2. The upper computer communicates with PLC by means of industrial Ethernet. Centralized monitoring and distributed control is achieved. Experimental results show that this measurement and control system has fulfilled the test requirement for the turbo-expander experimental platform.

  13. Development of a measurement and control system for a 10 kW@20 K refrigerator based on Siemens PLC S7-300

    Science.gov (United States)

    Li, J.; Liu, L. Q.; Liu, T.; Xu, X. D.; Dong, B.; Lu, W. H.; Pan, W.; Wu, J. H.; Xiong, L. Y.

    2017-02-01

    A 10 kW@20 K refrigerator has been established by the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. A measurement and control system based on Siemens PLC S7-300 for this 10 kW@20 K refrigerator is developed. According to the detailed measurement requirements, proper sensors and transmitters are adopted. Siemens S7-300 PLC CPU315-2 PN/DP operates as a master station. Two sets of ET200M DP remote expand I/O, one power meter, two compressors and one vacuum gauge operate as slave stations. Profibus-DP field communication and Modbus communication are used between the master station and the slave stations in this control system. The upper computer HMI (Human Machine Interface) is compiled using Siemens configuration software WinCC V7.0. The upper computer communicates with PLC by means of industrial Ethernet. After commissioning, this refrigerator has been operating with a 10 kW of cooling power at 20 K for more than 72 hours.

  14. Measurement and control system for cryogenic helium gas bearing turbo-expander experimental platform based on Siemens PLC S7-300

    Energy Technology Data Exchange (ETDEWEB)

    Li, J.; Xiong, L. Y.; Peng, N.; Dong, B.; Liu, L. Q. [Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190 (China); Wang, P. [Beijing Sciample Technology Co., Ltd., Beijing, 100190 (China)

    2014-01-29

    An experimental platform for cryogenic Helium gas bearing turbo-expanders is established at the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. This turbo-expander experimental platform is designed for performance testing and experimental research on Helium turbo-expanders with different sizes from the liquid hydrogen temperature to the room temperature region. A measurement and control system based on Siemens PLC S7-300 for this turbo-expander experimental platform is developed. Proper sensors are selected to measure such parameters as temperature, pressure, rotation speed and air flow rate. All the collected data to be processed are transformed and transmitted to S7-300 CPU. Siemens S7-300 series PLC CPU315-2PN/DP is as master station and two sets of ET200M DP remote expand I/O is as slave station. Profibus-DP field communication is established between master station and slave stations. The upper computer Human Machine Interface (HMI) is compiled using Siemens configuration software WinCC V6.2. The upper computer communicates with PLC by means of industrial Ethernet. Centralized monitoring and distributed control is achieved. Experimental results show that this measurement and control system has fulfilled the test requirement for the turbo-expander experimental platform.

  15. PET studies in dementia

    International Nuclear Information System (INIS)

    Herholz, K.

    2003-01-01

    Measurement of local cerebral glucose metabolism (lCMRGlc) by positron emission tomography (PET) and 18 F-2-fluoro-2-deoxy-D-glucose (FDG) has become a standard technique during the past 20 years and is now available at many university hospitals in all highly developed countries. Many studies have documented a close relation between lCMRGlc and localized cognitive functions, such as language and visuoconstructive abilities. Alzheimer's disease (AD) is characterized by regional impairment of cerebral glucose metabolism in neocortical association areas (posterior cingulate, temporoparietal and frontal multimodal association cortex), whereas primary visual and sensorimotor cortex, basal ganglia, and cerebellum are relatively well preserved. In a multicenter study comprising 10 PET centers (Network for Efficiency and Standardization of Dementia Diagnosis, NEST-DD) that employed an automated voxel-based analysis of FDG PET images, the distinction between controls and AD patients was 93% sensitive and 93% specific, and even in very mild dementia (at Mini Mental Status Examination (MMSE) 24 or higher) sensitivity was still 84% at 93% specificity. Significantly abnormal metabolism in mild cognitive deficit (MCI) indicates a high risk to develop dementia within the next two years. Reduced neocortical glucose metabolism can probably be detected with FDG PET in AD on average one year before onset of subjective cognitive impairment. In addition to glucose metabolism, specific tracers for dopamine synthesis ( 18 F-F-DOPA) and for ( 11 C-MP4A) are of interest for differentiation among dementia subtypes. Cortical acetylcholine esterase activity (AChE) activity is significantly lower in patients with AD or with dementia with Lewy bodies (DLB) than in age-matched normal controls. In LBD there is also impairment of dopamine synthesis, similar to Parkinson disease. (author) 115 refs

  16. PET studies in dementia

    Energy Technology Data Exchange (ETDEWEB)

    Herholz, K. [Neurologische Universitaetsklinik and Max-Planck-Inst. fuer neurologische Forschung, Koeln (Germany)

    2003-04-01

    Measurement of local cerebral glucose metabolism (lCMRGlc) by positron emission tomography (PET) and {sup 18}F-2-fluoro-2-deoxy-D-glucose (FDG) has become a standard technique during the past 20 years and is now available at many university hospitals in all highly developed countries. Many studies have documented a close relation between lCMRGlc and localized cognitive functions, such as language and visuoconstructive abilities. Alzheimer's disease (AD) is characterized by regional impairment of cerebral glucose metabolism in neocortical association areas (posterior cingulate, temporoparietal and frontal multimodal association cortex), whereas primary visual and sensorimotor cortex, basal ganglia, and cerebellum are relatively well preserved. In a multicenter study comprising 10 PET centers (Network for Efficiency and Standardization of Dementia Diagnosis, NEST-DD) that employed an automated voxel-based analysis of FDG PET images, the distinction between controls and AD patients was 93% sensitive and 93% specific, and even in very mild dementia (at Mini Mental Status Examination (MMSE) 24 or higher) sensitivity was still 84% at 93% specificity. Significantly abnormal metabolism in mild cognitive deficit (MCI) indicates a high risk to develop dementia within the next two years. Reduced neocortical glucose metabolism can probably be detected with FDG PET in AD on average one year before onset of subjective cognitive impairment. In addition to glucose metabolism, specific tracers for dopamine synthesis ({sup 18}F-F-DOPA) and for ({sup 11}C-MP4A) are of interest for differentiation among dementia subtypes. Cortical acetylcholine esterase activity (AChE) activity is significantly lower in patients with AD or with dementia with Lewy bodies (DLB) than in age-matched normal controls. In LBD there is also impairment of dopamine synthesis, similar to Parkinson disease. (author) 115 refs.

  17. Pet Overpopulation: An Economic Analysis

    OpenAIRE

    Stephen Coate; Brian Knight

    2009-01-01

    This paper considers the problem of pet overpopulation. It develops a tractable dynamic model whose positive predictions square well with key features of the current U.S. market for pets. The model is used to understand, from a welfare economic perspective, the sense in which there is \\overpopulation" of pets and the underlying causes of the problem. The paper also employs the model to consider what policies might be implemented to deal with the problem. A calibrated example is developed to i...

  18. Click synthesis of PET radiopharmaceuticals

    International Nuclear Information System (INIS)

    Xu Mei; Kuang Chunxiang

    2009-01-01

    Increasing attention has been focused on synthesis radiopharmaceuticals for positron emission tomography (PET). The recent years witnessed applications of click chemistry to PET radiopharmaceutical synthesis,because of its distinctive advantages including high speed,yield and stereospecificity under mild conditions. Synthesis of 18 F-labeled and 11 C-labeled radiopharmaceuticals and intermediates via click chemistry are reviewed. The future trend of click chemistry for the synthesis of PET radiopharmaceutical is prospected. (authors)

  19. Initial reconstruction results from a simulated adaptive small animal C shaped PET/MR insert

    Energy Technology Data Exchange (ETDEWEB)

    Efthimiou, Nikos [Technological Educational Institute of Athens (Greece); Kostou, Theodora; Papadimitroulas, Panagiotis [Technological Educational Institute of Athens (Greece); Department of Medical Physics, School of Medicine, University of Patras (Greece); Charalampos, Tsoumpas [Division of Biomedical Imaging, University of Leeds, Leeds (United Kingdom); Loudos, George [Technological Educational Institute of Athens (Greece)

    2015-05-18

    Traditionally, most clinical and preclinical PET scanners, rely on full cylindrical geometry for whole body as well as dedicated organ scans, which is not optimized with regards to sensitivity and resolution. Several groups proposed the construction of dedicated PET inserts for MR scanners, rather than the construction of new integrated PET/MR scanners. The space inside an MR scanner is a limiting factor which can be reduced further with the use of extra coils, and render the use of non-flexible cylindrical PET scanners difficult if not impossible. The incorporation of small SiPM arrays, can provide the means to design adaptive PET scanners to fit in tight locations, which, makes imaging possible and improve the sensitivity, due to the closer approximation to the organ of interest. In order to assess the performance of such a device we simulated the geometry of a C shaped PET, using GATE. The design of the C-PET was based on a realistic SiPM-BGO scenario. In order reconstruct the simulated data, with STIR, we had to calculate system probability matrix which corresponds to this non standard geometry. For this purpose we developed an efficient multi threaded ray tracing technique to calculate the line integral paths in voxel arrays. One of the major features is the ability to automatically adjust the size of FOV according to the geometry of the detectors. The initial results showed that the sensitivity improved as the angle between the detector arrays increases, thus better angular sampling the scanner's field of view (FOV). The more complete angular coverage helped in improving the shape of the source in the reconstructed images, as well. Furthermore, by adapting the FOV to the closer to the size of the source, the sensitivity per voxel is improved.

  20. Initial reconstruction results from a simulated adaptive small animal C shaped PET/MR insert

    International Nuclear Information System (INIS)

    Efthimiou, Nikos; Kostou, Theodora; Papadimitroulas, Panagiotis; Charalampos, Tsoumpas; Loudos, George

    2015-01-01

    Traditionally, most clinical and preclinical PET scanners, rely on full cylindrical geometry for whole body as well as dedicated organ scans, which is not optimized with regards to sensitivity and resolution. Several groups proposed the construction of dedicated PET inserts for MR scanners, rather than the construction of new integrated PET/MR scanners. The space inside an MR scanner is a limiting factor which can be reduced further with the use of extra coils, and render the use of non-flexible cylindrical PET scanners difficult if not impossible. The incorporation of small SiPM arrays, can provide the means to design adaptive PET scanners to fit in tight locations, which, makes imaging possible and improve the sensitivity, due to the closer approximation to the organ of interest. In order to assess the performance of such a device we simulated the geometry of a C shaped PET, using GATE. The design of the C-PET was based on a realistic SiPM-BGO scenario. In order reconstruct the simulated data, with STIR, we had to calculate system probability matrix which corresponds to this non standard geometry. For this purpose we developed an efficient multi threaded ray tracing technique to calculate the line integral paths in voxel arrays. One of the major features is the ability to automatically adjust the size of FOV according to the geometry of the detectors. The initial results showed that the sensitivity improved as the angle between the detector arrays increases, thus better angular sampling the scanner's field of view (FOV). The more complete angular coverage helped in improving the shape of the source in the reconstructed images, as well. Furthermore, by adapting the FOV to the closer to the size of the source, the sensitivity per voxel is improved.

  1. The diagnostic value of 13N-ammonia PET in ischemic cerebrovascular disorders

    International Nuclear Information System (INIS)

    Qiao Shuixian; Tang Anwu; Wang Lijuan; Liu Xintong; Yuan Yanbo; Chen Liguang; Luo Yaowu; Zhang Xiangsong; Wang Shuxia; Liu Bin; Xu Weiping

    2002-01-01

    Objective: To evaluate the feasibility of 13 N-ammonia PET in diagnosing ischemic cerebrovascular disorders. Methods: A total of 25 subjects were investigated. Five healthy volunteers served as normal control. Twenty patients included 13 with transient ischemic attack (TIA), 6 with brain infarction and 1 with moyamoya disease. 740-925 MBq of 13 N-ammonia was injected intravenously, 3-5 min later, PET imaging was performed with T + E 2D acquisition with Siemens ECAT EXACT HR + PET scanner. Image analysis was done by visual and semiquantitative estimating. Standardized uptake value (SUV) was measured in mirror regions of cerebrum with autocopy methods. Nine patients underwent drug stress with oral acetazolamide (ACZ). Images were compared before and after oral ACZ intervention. Results: Physiological brain uptake with SUV ratio of 0.99 +- 0.15 (n=5, left/right) was observed in healthy volunteers. L/N 13 N-ammonia as radioactive tracer was a safe and noninvasive, sensitive and accurate functional imaging modality for brain perfusion. The oral ACZ stress is a safe, simple and reliable diagnostic method for ischemic cerebrovascular disorders. It is of important uses in detecting the potential reserve of cerebral blood flow

  2. Compton scatter and randoms corrections for origin ensembles 3D PET reconstructions

    Energy Technology Data Exchange (ETDEWEB)

    Sitek, Arkadiusz [Harvard Medical School, Boston, MA (United States). Dept. of Radiology; Brigham and Women' s Hospital, Boston, MA (United States); Kadrmas, Dan J. [Utah Univ., Salt Lake City, UT (United States). Utah Center for Advanced Imaging Research (UCAIR)

    2011-07-01

    In this work we develop a novel approach to correction for scatter and randoms in reconstruction of data acquired by 3D positron emission tomography (PET) applicable to tomographic reconstruction done by the origin ensemble (OE) approach. The statistical image reconstruction using OE is based on calculation of expectations of the numbers of emitted events per voxel based on complete-data space. Since the OE estimation is fundamentally different than regular statistical estimators such those based on the maximum likelihoods, the standard methods of implementation of scatter and randoms corrections cannot be used. Based on prompts, scatter, and random rates, each detected event is graded in terms of a probability of being a true event. These grades are utilized by the Markov Chain Monte Carlo (MCMC) algorithm used in OE approach for calculation of the expectation over the complete-data space of the number of emitted events per voxel (OE estimator). We show that the results obtained with the OE are almost identical to results obtained by the maximum likelihood-expectation maximization (ML-EM) algorithm for reconstruction for experimental phantom data acquired using Siemens Biograph mCT 3D PET/CT scanner. The developed correction removes artifacts due to scatter and randoms in investigated 3D PET datasets. (orig.)

  3. PET and Recycling

    Directory of Open Access Journals (Sweden)

    Funda Sevencan

    2007-08-01

    Full Text Available This review aims to clarify the need of decreasing the environmental effects caused by human and draw attention to the increasing environmental effects of plastics wastes. Plastics consist of organic molecules with high density molecules or polymers. Main resources of plastics are the residue of oil rafineries. Several advantages of plastics, have increased the usage continuously. Polyethylene Terephthalate (PET is the most commonly used plastics. PET is used to protect food, drinking water, fruit juice, alcoholic beverage, and food packing films. By the increasing interest on the environmental effects of plastic wastes, concerns on the recyclable packing materials also grew up. Also the daily use of recyclable containers consisting PET have increased. There are five steps for recycling of plastics. These steps are; using large amounts of plastics, collecting them in a big center, classifying and sorting the plastics, reproducing the polymers and obtaining new products with melted plastics. Providing a healthy recycling of plastics, the consumers should have knowledge and responsibility. The consumer should know what he/she has to do before putting the plastics in the recycling containers. Recycling containers and bags should be placed near the sources of plastic wastes. Consequently, the plastic wastes and environmental problems they cause will be on the agenda in future. [TAF Prev Med Bull. 2007; 6(4: 307-312

  4. PET and Recycling

    Directory of Open Access Journals (Sweden)

    Funda Sevencan

    2007-08-01

    Full Text Available This review aims to clarify the need of decreasing the environmental effects caused by human and draw attention to the increasing environmental effects of plastics wastes. Plastics consist of organic molecules with high density molecules or polymers. Main resources of plastics are the residue of oil rafineries. Several advantages of plastics, have increased the usage continuously. Polyethylene Terephthalate (PET is the most commonly used plastics. PET is used to protect food, drinking water, fruit juice, alcoholic beverage, and food packing films. By the increasing interest on the environmental effects of plastic wastes, concerns on the recyclable packing materials also grew up. Also the daily use of recyclable containers consisting PET have increased. There are five steps for recycling of plastics. These steps are; using large amounts of plastics, collecting them in a big center, classifying and sorting the plastics, reproducing the polymers and obtaining new products with melted plastics. Providing a healthy recycling of plastics, the consumers should have knowledge and responsibility. The consumer should know what he/she has to do before putting the plastics in the recycling containers. Recycling containers and bags should be placed near the sources of plastic wastes. Consequently, the plastic wastes and environmental problems they cause will be on the agenda in future. [TAF Prev Med Bull 2007; 6(4.000: 307-312

  5. A prospective multi-centre study of the value of FDG-PET as part of a structured diagnostic protocol in patients with fever of unknown origin

    International Nuclear Information System (INIS)

    Bleeker-Rovers, Chantal P.; Vos, Fidel J.; Meer, Jos W.M. van der; Mudde, Aart H.; Dofferhoff, Anton S.M.; Geus-Oei, Lioe-Fee de; Rijnders, Anton J.; Krabbe, Paul F.M.; Corstens, Frans H.M.; Oyen, Wim J.G.

    2007-01-01

    Since 18 F-fluorodeoxyglucose (FDG) accumulates in neoplastic cells and in activated inflammatory cells, positron emission tomography (PET) with FDG could be valuable in diagnosing patients with fever of unknown origin (FUO). The aim of this study was to validate the use of FDG-PET as part of a structured diagnostic protocol in the general patient population with FUO. From December 2003 to July 2005, 70 patients with FUO were recruited from one university hospital (n=38) and five community hospitals (n=32). A structured diagnostic protocol including FDG-PET was used. A dedicated, full-ring PET scanner was used for data acquisition. FDG-PET scans were interpreted by two staff members of the department of nuclear medicine without further clinical information. The final clinical diagnosis was used for comparison with the FDG-PET results. Of all scans, 33% were clinically helpful. The contribution of FDG-PET to the final diagnosis did not differ significantly between patients diagnosed in the university hospital and patients diagnosed in the community hospitals. FDG-PET contributed significantly more often to the final diagnosis in patients with continuous fever than in patients with periodic fever. FDG-PET was not helpful in any of the patients with normal erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP). FDG-PET is a valuable imaging technique as part of a diagnostic protocol in the general patient population with FUO and a raised ESR or CRP. (orig.)

  6. Extended suicide with a pet.

    Science.gov (United States)

    Cooke, Brian K

    2013-01-01

    The combination of the killing of a pet and a suicide is a perplexing scenario that is largely unexplored in the literature. Many forensic psychiatrists and psychologists may be unaccustomed to considering the significance of the killing of a pet. The subject is important, however, because many people regard their pets as members of their family. A case is presented of a woman who killed her pet dog and herself by carbon monoxide poisoning. The purpose of this article is to provide an initial exploration of the topic of extended suicide with a pet. Forensic mental health evaluations may have a role in understanding the etiology of this event and in opining as to the culpability of individuals who attempt to or successfully kill a pet and then commit suicide. Because the scientific literature is lacking, there is a need to understand this act from a variety of perspectives. First, a social and anthropological perspective will be presented that summarizes the history of the practice of killing of one's pet, with a focus on the ancient Egyptians. A clinical context will examine what relationship animals have to mental illness. A vast body of existing scientific data showing the relevance of human attachment to pets suggests that conclusions from the phenomena of homicide-suicide and filicide-suicide are applicable to extended suicide with a pet. Finally, recommendations will be proposed for both clinical and forensic psychiatrists faced with similar cases.

  7. PET/CT and radiotherapy

    International Nuclear Information System (INIS)

    Messa, C.; CNR, Milano; S. Gerardo Hospital, Monza; Di Muzio, N.; Picchio, M.; Bettinardi, V.; Gilardi, M.C.; CNR, Milano; San Raffaele Scientific Institute, Milano; Fazio, F.; CNR, Milano; San Raffaele Scientific Institute, Milano; San Raffaele Scientific Institute, Milano

    2006-01-01

    This article reviews the state of the art of PET/CT applications in radiotherapy, specifically its use in disease staging, patient selection, treatment planning and treatment evaluation. Diseases for which radiotherapy with radical intent is indicated will be considered, as well as those in which PET/CT may actually change the course of disease. The methodological and technological aspects of PET/CT in radiotherapy are discussed, focusing on the problem of target volume definition with CT and PET functional imaging and the problem of tumor motion with respect to imaging and dose delivery

  8. Thoracic cavity definition for 3D PET/CT analysis and visualization.

    Science.gov (United States)

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W; Higgins, William E

    2015-07-01

    X-ray computed tomography (CT) and positron emission tomography (PET) serve as the standard imaging modalities for lung-cancer management. CT gives anatomical details on diagnostic regions of interest (ROIs), while PET gives highly specific functional information. During the lung-cancer management process, a patient receives a co-registered whole-body PET/CT scan pair and a dedicated high-resolution chest CT scan. With these data, multimodal PET/CT ROI information can be gleaned to facilitate disease management. Effective image segmentation of the thoracic cavity, however, is needed to focus attention on the central chest. We present an automatic method for thoracic cavity segmentation from 3D CT scans. We then demonstrate how the method facilitates 3D ROI localization and visualization in patient multimodal imaging studies. Our segmentation method draws upon digital topological and morphological operations, active-contour analysis, and key organ landmarks. Using a large patient database, the method showed high agreement to ground-truth regions, with a mean coverage=99.2% and leakage=0.52%. Furthermore, it enabled extremely fast computation. For PET/CT lesion analysis, the segmentation method reduced ROI search space by 97.7% for a whole-body scan, or nearly 3 times greater than that achieved by a lung mask. Despite this reduction, we achieved 100% true-positive ROI detection, while also reducing the false-positive (FP) detection rate by >5 times over that achieved with a lung mask. Finally, the method greatly improved PET/CT visualization by eliminating false PET-avid obscurations arising from the heart, bones, and liver. In particular, PET MIP views and fused PET/CT renderings depicted unprecedented clarity of the lesions and neighboring anatomical structures truly relevant to lung-cancer assessment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Operating dedicated data centers – is it cost-effective?

    International Nuclear Information System (INIS)

    Ernst, M; Hogue, R; Hollowell, C; Strecker-Kellog, W; Wong, A; Zaytsev, A

    2014-01-01

    The advent of cloud computing centres such as Amazon's EC2 and Google's Computing Engine has elicited comparisons with dedicated computing clusters. Discussions on appropriate usage of cloud resources (both academic and commercial) and costs have ensued. This presentation discusses a detailed analysis of the costs of operating and maintaining the RACF (RHIC and ATLAS Computing Facility) compute cluster at Brookhaven National Lab and compares them with the cost of cloud computing resources under various usage scenarios. An extrapolation of likely future cost effectiveness of dedicated computing resources is also presented.

  10. Operating Dedicated Data Centers - Is It Cost-Effective?

    Science.gov (United States)

    Ernst, M.; Hogue, R.; Hollowell, C.; Strecker-Kellog, W.; Wong, A.; Zaytsev, A.

    2014-06-01

    The advent of cloud computing centres such as Amazon's EC2 and Google's Computing Engine has elicited comparisons with dedicated computing clusters. Discussions on appropriate usage of cloud resources (both academic and commercial) and costs have ensued. This presentation discusses a detailed analysis of the costs of operating and maintaining the RACF (RHIC and ATLAS Computing Facility) compute cluster at Brookhaven National Lab and compares them with the cost of cloud computing resources under various usage scenarios. An extrapolation of likely future cost effectiveness of dedicated computing resources is also presented.

  11. PET/MR brain imaging: evaluation of clinical UTE-based attenuation correction

    International Nuclear Information System (INIS)

    Aasheim, Lars Birger; Karlberg, Anna; Goa, Paal Erik; Haaberg, Asta; Soerhaug, Sveinung; Fagerli, Unn-Merete; Eikenes, Live

    2015-01-01

    One of the greatest challenges in PET/MR imaging is that of accurate MR-based attenuation correction (AC) of the acquired PET data, which must be solved if the PET/MR modality is to reach its full potential. The aim of this study was to investigate the performance of Siemens' most recent version (VB20P) of MR-based AC of head PET data, by comparing it to CT-based AC. Methods: 18 F-FDG PET data from seven lymphoma and twelve lung cancer patients examined with a Biograph mMR PET/MR system were reconstructed with both CT-based and MR-based AC, avoiding sources of error arising when comparing PET data from different systems. The resulting images were compared quantitatively by measuring changes in mean SUV in ten different brain regions in both hemispheres, as well as the brainstem. In addition, the attenuation maps (μ maps) were compared regarding volume and localization of cranial bone. The UTE μ maps clearly overestimate the amount of bone in the neck, while slightly underestimating the amount of bone in the cranium, and the localization of bone in the cranial region also differ from the CT μ maps. In air/tissue interfaces in the sinuses and ears, the MRAC method struggles to correctly classify the different tissues. The misclassification of tissue is most likely caused by a combination of artefacts and the insufficiency of the UTE method to accurately separate bone. Quantitatively, this results in a combination of overestimation (0.5-3.6 %) and underestimation (2.7-5.2 %) of PET activity throughout the brain, depending on the proximity to the inaccurate regions. Our results indicate that the performance of the UTE method as implemented in VB20P is close to the theoretical maximum of such an MRAC method in the brain, while it does not perform satisfactorily in the neck or face/nasal area. Further improvement of the UTE MRAC or other available methods for more accurate segmentation of bone should be incorporated. (orig.)

  12. Cost-effectiveness of PET and PET/Computed Tomography

    DEFF Research Database (Denmark)

    Gerke, Oke; Hermansson, Ronnie; Hess, Søren

    2015-01-01

    measure by means of incremental cost-effectiveness ratios when considering the replacement of the standard regimen by a new diagnostic procedure. This article discusses economic assessments of PET and PET/computed tomography reported until mid-July 2014. Forty-seven studies on cancer and noncancer...

  13. Usefulness of FDG PET for nodal staging using a dual head coincidence camera in patients with lung cancer

    International Nuclear Information System (INIS)

    Yoon, Seok Nam; Park, Chan H.; Lee, Myoung Hoon; Hwang, Kyung Hoon; Hwang, Kyung Hoon

    2001-01-01

    Staging of lung cancer requires an accurate evaluation of the mediastinum. Positron imaging with dual head cameras may be not as sensitive as dedicated PET. Therefore, the purpose of the study was to evaluated the usefulness of F-18 FDG coincidence (CoDe) PET using a dual-head gamma camera in the nodal staging of the lung cancer. CoDe-PET studies were performed in 51 patients with histologically proven non small cell lung cancer. CoDe-PET began 60 minutes after the injection of 111-185 MBq of F-18 FDG. CoDe-PET was performed using a dual-head gamma camera equipped with coincidence detection circuitry (Elscints Varicam, Haifa, lsrael). There was no attenuation correction made and reconstruction was done using a filtered back-projection. Surgery was performed in 49 patients CoDe-PET studies were evaluated visually. Any focal increased uptake was considered abnormal. The nodal stating of CoDe-PET studies were evaluated visually. Any focal increased uptake was considered abnormal. The nodal staging of CoDe-PET and of CT were compared with the nodal stating of surgical (49) and mediastinoscopical (2) pathology. All primary lung lesions were hypermetabolic and easily visualized. Compared with surgical nodal staging as a gold standard, false positives occurred in 13 CoDe PET and 17 CT studies and false negative occurred in 5 CoDe-PET and 4 CT studies. Assessment of lymph node involvement by CoDe-PET depicted a sensitivity of 67%, specificity of 64% and accuracy of 65%. CT revealed a sensitivity of 73%, specificity of 53% and accuracy of 59% in the assessment of lymph node involvement. The detection of primary lesions were 100% but nodal staging was suboptimal for routine clinical use. This is mainly due to limited resolution of our system

  14. Quantification and reduction of peripheral dose from leakage radiation on Siemens Primus accelerators in electron therapy mode.

    Science.gov (United States)

    Yeboah, Collins; Karotki, Alex; Hunt, Dylan; Holly, Rick

    2010-06-15

    In this work, leakage radiation from EA200 series electron applicators on Siemens Primus accelerators is quantified, and its penetration ability in water and/or the shielding material Xenolite-NL established. Initially, measurement of leakage from 10 x 10 - 25 x 25 cm2 applicators was performed as a function of height along applicator and of lateral distance from applicator body. Relative to central-axis ionization maximum in solid water, the maximum leakage in air observed with a cylindrical ion chamber with 1 cm solid water buildup cap at a lateral distance of 2 cm from the front and right sidewalls of applicators were 17% and 14%, respectively; these maxima were recorded for 18 MeV electron beams and applicator sizes of >or=20 x 20 cm2. In the patient plane, the applicator leakage gave rise to a broad peripheral dose off-axis distance peak that shifted closer to the field edge as the electron energy increases. The maximum peripheral dose from normally incident primary electron beams at a depth of 1 cm in a water phantom was observed to be equal to 5% of the central-axis dose maximum and as high as 9% for obliquely incident beams with angles of obliquity dose curves showed that the "practical range" of the leakage electrons in water varies from approximately 1.4 to 5.7 cm as the primary electron beam energy is raised from 6 to 18 MeV. Next, transmission measurements of leakage radiation through the shielding material Xenolite-NL showed a 4 mm thick sheet of this material is required to attenuate the leakage from 9 MeV beams by two-thirds, and that for every additional 3 MeV increase in the primary electron beam energy, an additional Xenolite-NL thickness of roughly 2 mm is needed to achieve the aforementioned attenuation level. Finally, attachment of a 1 mm thick sheet of lead to the outer surface of applicator sidewalls resulted in a reduction of the peripheral dose by up to 80% and 74% for 9 and 18MeV beams, respectively. This sidewall modification had an

  15. SU-C-201-07: Validation of a GATE Gamma Camera Model for the Siemens Symbia

    International Nuclear Information System (INIS)

    Mikell, J; Siman, W; Kappadath, S; Mourtada, F

    2015-01-01

    Purpose: To develop a simulation model of a clinical gamma camera/SPECT system and to validate the model using experimental and published measurements from the clinical system. Methods: Geant4 Application for Tomographic Emission (GATE) was used to create a model of the Siemens Symbia gamma camera. A modular model was implemented that allows specifying combinations of crystal thickness (3/8”, 5/8”) and collimator (LEHR, MELP, HE). Shielding, energy resolution, intrinsic resolution, crystal thickness, and collimator properties were set based on manufacturer specifications. Validation of the model was performed by simulating NEMA 2007 gamma camera tests including spatial resolution and sensitivity for Tc99; these were compared with experimental and published data for the scanner. The simulated energy spectra of a Tc99 line source in acrylic blocks was visually compared with the corresponding experimental acquisition. For a 4 cm diameter sphere filled with Tc99, the attenuation maps were generated from simulation data, and the photopeak and scatter window were extracted from GATE output using ROOT to create DICOM files to use in the clinical reconstruction. Results: Simulated spatial resolutions for LEHR 3/8” crystal at 0, 10 cm, 10 cm (with scatter), and 30 cm were 4, 6.7, 7.9, and 14.5 mm FWHM; these were 9% less than published data. For 5/8” crystal the spatial resolutions were 4.5, 7.0, 8.5, and 14.7 mm FWHM; these were 4% to 10% less than published data. Simulated sensitivity was within 3.5% of published data for both LEHR 3/8” and 5/8”. The simulated energy spectra matched the photopeak and scatter window well, but did overestimate the counts below 90 keV. The simulated attenuation map and projection data were successfully reconstructed with the clinical software, and the passed visual inspection. Conclusions: Validation of a specific clinical scanner allows future studies of quantification accuracy for both planar and SPECT imaging. Research

  16. SU-C-201-07: Validation of a GATE Gamma Camera Model for the Siemens Symbia

    Energy Technology Data Exchange (ETDEWEB)

    Mikell, J; Siman, W; Kappadath, S [Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, TX (United States); University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX (United States); Mourtada, F [Christiana Care Hospital, Newark, DE (United States); Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston TX (United States); Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, PA (United States)

    2015-06-15

    Purpose: To develop a simulation model of a clinical gamma camera/SPECT system and to validate the model using experimental and published measurements from the clinical system. Methods: Geant4 Application for Tomographic Emission (GATE) was used to create a model of the Siemens Symbia gamma camera. A modular model was implemented that allows specifying combinations of crystal thickness (3/8”, 5/8”) and collimator (LEHR, MELP, HE). Shielding, energy resolution, intrinsic resolution, crystal thickness, and collimator properties were set based on manufacturer specifications. Validation of the model was performed by simulating NEMA 2007 gamma camera tests including spatial resolution and sensitivity for Tc99; these were compared with experimental and published data for the scanner. The simulated energy spectra of a Tc99 line source in acrylic blocks was visually compared with the corresponding experimental acquisition. For a 4 cm diameter sphere filled with Tc99, the attenuation maps were generated from simulation data, and the photopeak and scatter window were extracted from GATE output using ROOT to create DICOM files to use in the clinical reconstruction. Results: Simulated spatial resolutions for LEHR 3/8” crystal at 0, 10 cm, 10 cm (with scatter), and 30 cm were 4, 6.7, 7.9, and 14.5 mm FWHM; these were 9% less than published data. For 5/8” crystal the spatial resolutions were 4.5, 7.0, 8.5, and 14.7 mm FWHM; these were 4% to 10% less than published data. Simulated sensitivity was within 3.5% of published data for both LEHR 3/8” and 5/8”. The simulated energy spectra matched the photopeak and scatter window well, but did overestimate the counts below 90 keV. The simulated attenuation map and projection data were successfully reconstructed with the clinical software, and the passed visual inspection. Conclusions: Validation of a specific clinical scanner allows future studies of quantification accuracy for both planar and SPECT imaging. Research

  17. Feasibility and acceptance of simultaneous amyloid PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Schuetz, Lisa; Tiepolt, Solveig; Werner, Peter; Jochimsen, Thies; Rullmann, Michael; Sattler, Bernhard; Patt, Marianne; Barthel, Henryk [Leipzig University Hospital, Department of Nuclear Medicine, Leipzig (Germany); Lobsien, Donald; Fritzsch, Dominik; Hoffmann, Karl-Titus [Leipzig University Hospital, Department of Neuroradiology, Leipzig (Germany); Schroeter, Matthias L.; Villringer, Arno [Leipzig University Hospital and Max Planck Institute for Human Cognitive and Brain Sciences, Day Clinic for Cognitive Neurology, Leipzig (Germany); Leipzig University Hospital, IFB Adiposity Diseases, Leipzig (Germany); Berrouschot, Joerg [Clinical Centre Altenburger Land, Altenburg (Germany); Saur, Dorothee; Classen, Joseph [Leipzig University Hospital, Department of Neurology, Leipzig (Germany); Hesse, Swen; Sabri, Osama [Leipzig University Hospital, Department of Nuclear Medicine, Leipzig (Germany); Leipzig University Hospital, IFB Adiposity Diseases, Leipzig (Germany); Gertz, Hermann-Josef [Leipzig University Hospital, Department of Psychiatry, Leipzig (Germany)

    2016-11-15

    Established Alzheimer's disease (AD) biomarker concepts classify into amyloid pathology and neuronal injury biomarkers, while recent alternative concepts classify into diagnostic and progression AD biomarkers. However, combined amyloid positron emission tomography/magnetic resonance imaging (PET/MRI) offers the chance to obtain both biomarker category read-outs within one imaging session, with increased patient as well as referrer convenience. The aim of this pilot study was to investigate this matter for the first time. 100 subjects (age 70 ± 10 yrs, 46 female), n = 51 with clinically defined mild cognitive impairment (MCI), n = 44 with possible/probable AD dementia, and n = 5 with frontotemporal lobe degeneration, underwent simultaneous [{sup 18}F]florbetaben or [{sup 11}C]PIB PET/MRI (3 Tesla Siemens mMR). Brain amyloid load, mesial temporal lobe atrophy (MTLA) by means of the Scheltens scale, and other morphological brain pathologies were scored by respective experts. The patients/caregivers as well as the referrers were asked to assess on a five-point scale the convenience related to the one-stop-shop PET and MRI approach. In three subjects, MRI revealed temporal lobe abnormalities other than MTLA. According to the National Institute on Aging-Alzheimer's Association classification, the combined amyloid-beta PET/MRI evaluation resulted in 31 %, 45 %, and 24 % of the MCI subjects being categorized as ''MCI-unlikely due to AD'', ''MCI due to AD-intermediate likelihood'', and ''MCI due to AD-high likelihood'', respectively. 50 % of the probable AD dementia patients were categorized as ''High level of evidence of AD pathophysiological process'', and 56 % of the possible AD dementia patients as ''Possible AD dementia - with evidence of AD pathophysiological process''. With regard to the International Working Group 2 classification, 36 subjects had both

  18. Pseudomonas aeruginosa burn wound infection in a dedicated ...

    African Journals Online (AJOL)

    Background. Pseudomonas aeruginosa infection is a major cause of morbidity in burns patients. There is a paucity of publications dealing with this infection in the paediatric population. We describe the incidence, microbiology and impact of P. aeruginosa infection in a dedicated paediatric burns unit. Methods.

  19. Dedicating time to volunteering : Values, engagement, and commitment to beneficiaries

    NARCIS (Netherlands)

    Shantz, A.; Saksida, T.; Alfes, K.

    2014-01-01

    A moderated mediation model was developed to explain the variation in the amount of time volunteers dedicate to their chosen voluntary cause. Data from 534 volunteers of an international aid and development agency in the United Kingdom revealed a positive relationship between prosocial values and

  20. Commercial Grade Item (CGI) Dedication for Leak Detection Relays

    International Nuclear Information System (INIS)

    KOCH, M.R.; JOHNS, B.R.

    1999-01-01

    This Test Plan provides a test method to dedicate the leak detection relays used on the new Pumping and Instrumentation Control (PIC) skids. The new skids are fabricated on-site. The leak detection system is a safety class system per the Authorization Basis

  1. Spectrograph dedicated to measuring tropospheric trace gas constituents from space

    NARCIS (Netherlands)

    Vries, J. de; Laan, E.C.; Deutz, A.F.; Escudero-Sanz, I.; Bokhove, H.; Hoegee, J.; Aben, I.; Jongma, R.; Landgraf, J.; Hasekamp, O.P.; Houweling, S.; Weele, M. van; Oss, R. van; Oord, G. van den; Levelt, P.

    2005-01-01

    Several organizations in the Netherlands are cooperating to develop user requirements and instrument concepts in the line of SCIAMACHY and OMI but with an increased focus on measuring tropospheric constituents from space. The concepts use passive spectroscopy in dedicated wavelength sections in the

  2. Performance of TCP over UMTS common and dedicated channels

    NARCIS (Netherlands)

    Lo, Anthony; Heijenk, Geert; Bruma, Cezar; Gameiro, A.

    2003-01-01

    Universal Mobile Telecommunications System (UMTS) is a third-generation cellular network that enables high-speed wireless Internet access. This paper investigates the performance of Transmission Control Protocol (TCP) over UMTS utilizing a common and four dedicated transport channels with bit rates

  3. [Advanced online search techniques and dedicated search engines for physicians].

    Science.gov (United States)

    Nahum, Yoav

    2008-02-01

    In recent years search engines have become an essential tool in the work of physicians. This article will review advanced search techniques from the world of information specialists, as well as some advanced search engine operators that may help physicians improve their online search capabilities, and maximize the yield of their searches. This article also reviews popular dedicated scientific and biomedical literature search engines.

  4. Virginia Tech's College Of Natural Resources Dedicates Cheatham Hall Expansion

    OpenAIRE

    Davis, Lynn

    2003-01-01

    Thanks to funding by private donors, Alyce Cheatham and her family of Portland, Oregon, Virginia Tech's College of Natural Resources will dedicate a much-needed, three-story addition to its current Cheatham Hall on Wednesday, March 19, at 2:30 p.m.

  5. Cost of a dedicated ART clinic | Harling | South African Medical ...

    African Journals Online (AJOL)

    Abstract. Background. The provision of antiretroviral therapy (ART) is being rolled out across South Africa. Little evidence exists on the cost of running clinics for ART provision. Objectives. To determine the cost per patient-month enrolled in an ART programme and per patient-visit for a dedicated, public-sector ART clinic in a ...

  6. Service differentiation in spare parts supply through dedicated stocks

    NARCIS (Netherlands)

    Alvarez, Elisa; van der Heijden, Matthijs C.; Zijm, Willem H.M.

    2012-01-01

    We investigate keeping dedicated stocks at customer sites in addition to stock kept at some central location as a tool for applying service differentiation in spare parts supply. We study the resulting two-echelon system in a multi-item setting, both under backordering and under emergency shipments

  7. Towards Effective Non-Invasive Brain-Computer Interfaces Dedicated to Gait Rehabilitation Systems

    Directory of Open Access Journals (Sweden)

    Thierry Castermans

    2013-12-01

    Full Text Available In the last few years, significant progress has been made in the field of walk rehabilitation. Motor cortex signals in bipedal monkeys have been interpreted to predict walk kinematics. Epidural electrical stimulation in rats and in one young paraplegic has been realized to partially restore motor control after spinal cord injury. However, these experimental trials are far from being applicable to all patients suffering from motor impairments. Therefore, it is thought that more simple rehabilitation systems are desirable in the meanwhile. The goal of this review is to describe and summarize the progress made in the development of non-invasive brain-computer interfaces dedicated to motor rehabilitation systems. In the first part, the main principles of human locomotion control are presented. The paper then focuses on the mechanisms of supra-spinal centers active during gait, including results from electroencephalography, functional brain imaging technologies [near-infrared spectroscopy (NIRS, functional magnetic resonance imaging (fMRI, positron-emission tomography (PET, single-photon emission-computed tomography (SPECT] and invasive studies. The first brain-computer interface (BCI applications to gait rehabilitation are then presented, with a discussion about the different strategies developed in the field. The challenges to raise for future systems are identified and discussed. Finally, we present some proposals to address these challenges, in order to contribute to the improvement of BCI for gait rehabilitation.

  8. Computed tomography automatic exposure control techniques in 18F-FDG oncology PET-CT scanning.

    Science.gov (United States)

    Iball, Gareth R; Tout, Deborah

    2014-04-01

    Computed tomography (CT) automatic exposure control (AEC) systems are now used in all modern PET-CT scanners. A collaborative study was undertaken to compare AEC techniques of the three major PET-CT manufacturers for fluorine-18 fluorodeoxyglucose half-body oncology imaging. An audit of 70 patients was performed for half-body CT scans taken on a GE Discovery 690, Philips Gemini TF and Siemens Biograph mCT (all 64-slice CT). Patient demographic and dose information was recorded and image noise was calculated as the SD of Hounsfield units in the liver. A direct comparison of the AEC systems was made by scanning a Rando phantom on all three systems for a range of AEC settings. The variation in dose and image quality with patient weight was significantly different for all three systems, with the GE system showing the largest variation in dose with weight and Philips the least. Image noise varied with patient weight in Philips and Siemens systems but was constant for all weights in GE. The z-axis mA profiles from the Rando phantom demonstrate that these differences are caused by the nature of the tube current modulation techniques applied. The mA profiles varied considerably according to the AEC settings used. CT AEC techniques from the three manufacturers yield significantly different tube current modulation patterns and hence deliver different doses and levels of image quality across a range of patient weights. Users should be aware of how their system works and of steps that could be taken to optimize imaging protocols.

  9. Small Molecule PET-Radiopharmaceuticals

    NARCIS (Netherlands)

    Elsinga, Philip H.; Dierckx, Rudi A. J. O.

    This review describes several aspects required for the development of small molecule PET-tracers. Design and selection criteria are important to consider before starting to develop novel PET-tracers. Principles and latest trends in C-11 and F-18-radiochemistry are summarized. In addition an update

  10. Welfare assessment in pet rabbits

    NARCIS (Netherlands)

    Schepers, F.; Koene, P.; Beerda, B.

    2009-01-01

    One million pet rabbits are kept in The Netherlands, but there are no data available on their behaviour and welfare. This study seeks to assess the welfare of pet rabbits in Dutch households and is a first step in the development of a welfare assessment system. In an internet survey, housing

  11. Selected PET radiomic features remain the same.

    Science.gov (United States)

    Tsujikawa, Tetsuya; Tsuyoshi, Hideaki; Kanno, Masafumi; Yamada, Shizuka; Kobayashi, Masato; Narita, Norihiko; Kimura, Hirohiko; Fujieda, Shigeharu; Yoshida, Yoshio; Okazawa, Hidehiko

    2018-04-17

    We investigated whether PET radiomic features are affected by differences in the scanner, scan protocol, and lesion location using 18 F-FDG PET/CT and PET/MR scans. SUV, TMR, skewness, kurtosis, entropy, and homogeneity strongly correlated between PET/CT and PET/MR images. SUVs were significantly higher on PET/MR 0-2 min and PET/MR 0-10 min than on PET/CT in gynecological cancer ( p = 0.008 and 0.008, respectively), whereas no significant difference was observed between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images in oral cavity/oropharyngeal cancer. TMRs on PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min increased in this order in gynecological cancer and oral cavity/oropharyngeal cancer. In contrast to conventional and histogram indices, 4 textural features (entropy, homogeneity, SRE, and LRE) were not significantly different between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images. 18 F-FDG PET radiomic features strongly correlated between PET/CT and PET/MR images. Dixon-based attenuation correction on PET/MR images underestimated tumor tracer uptake more significantly in oral cavity/oropharyngeal cancer than in gynecological cancer. 18 F-FDG PET textural features were affected less by differences in the scanner and scan protocol than conventional and histogram features, possibly due to the resampling process using a medium bin width. Eight patients with gynecological cancer and 7 with oral cavity/oropharyngeal cancer underwent a whole-body 18 F-FDG PET/CT scan and regional PET/MR scan in one day. PET/MR scans were performed for 10 minutes in the list mode, and PET/CT and 0-2 min and 0-10 min PET/MR images were reconstructed. The standardized uptake value (SUV), tumor-to-muscle SUV ratio (TMR), skewness, kurtosis, entropy, homogeneity, short-run emphasis (SRE), and long-run emphasis (LRE) were compared between PET/CT, PET/MR 0-2 min , and PET/MR 0-10 min images.

  12. Neurotransmission imaging by PET

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Akihiro; Suhara, Tetsuya [National Inst. of Radiological Sciences, Chiba (Japan)

    2001-08-01

    PET studies on neurotransmission in psychological disorders to evaluate abnormal neurotransmission and therapeutic effects are thoroughly reviewed by type of major neurotransmitters. Studies on dopaminergic neurotransmission have focused on the function of dopamine D{sub 2} receptors, receptor subtypes, such as the D{sub 1} receptor, and ligands, such as transporters. PET studies of dopamine D{sub 2} receptor, which began in the early 1980s, have predominantly been performed in schizophrenia, and most have failed to detect any statistically significant differences between schizophrenia patients and controls. The studies in the early 1980s were performed by using [{sup 11}C]N-methyl-spiperone (NMSP) and [{sup 11}C]raclopride, ligands for striatal dopamine D{sub 2} receptors. [{sup 11}C]FLB457, which has much higher affinity for D{sub 2} receptors than raclopride, began to be used in the 1990s. Dopamine D{sub 2} occupancy after drug ingestion has also been investigated to clarify the mechanisms and effects of antipsychotic drugs, and there have also been studies on the effect of aging and personality traits on dopamine D{sub 2} receptor levels in healthy subjects. In studies on dopamine receptor subtypes other than D{sub 2}, dopamine D{sub 1} receptors have been studied in connection with assessments of cognitive functions. Most studies on dopamine transporters have been related to drug dependence. Serotonin 5-HT{sub 2A} receptors have been studied with [{sup 11}C]NMSP in schizophrenia patients, while studies of another serotonin receptor subtype, 5-HT{sub 1A} receptors, have been mainly conducted in patients with depression. [{sup 11}C]NMSP PET showed no difference between schizophrenia patients who had not undergone phamacotherapy and normal subjects. Because serotonin selective reuptake inhibitors (SSRIs) affect serotonin transporters, and abnormalities in serotonin transporters detected in mood disorders, PET ligands for serotonin transporters have increasingly

  13. Neurotransmission imaging by PET

    International Nuclear Information System (INIS)

    Takano, Akihiro; Suhara, Tetsuya

    2001-01-01

    PET studies on neurotransmission in psychological disorders to evaluate abnormal neurotransmission and therapeutic effects are thoroughly reviewed by type of major neurotransmitters. Studies on dopaminergic neurotransmission have focused on the function of dopamine D 2 receptors, receptor subtypes, such as the D 1 receptor, and ligands, such as transporters. PET studies of dopamine D 2 receptor, which began in the early 1980s, have predominantly been performed in schizophrenia, and most have failed to detect any statistically significant differences between schizophrenia patients and controls. The studies in the early 1980s were performed by using [ 11 C]N-methyl-spiperone (NMSP) and [ 11 C]raclopride, ligands for striatal dopamine D 2 receptors. [ 11 C]FLB457, which has much higher affinity for D 2 receptors than raclopride, began to be used in the 1990s. Dopamine D 2 occupancy after drug ingestion has also been investigated to clarify the mechanisms and effects of antipsychotic drugs, and there have also been studies on the effect of aging and personality traits on dopamine D 2 receptor levels in healthy subjects. In studies on dopamine receptor subtypes other than D 2 , dopamine D 1 receptors have been studied in connection with assessments of cognitive functions. Most studies on dopamine transporters have been related to drug dependence. Serotonin 5-HT 2A receptors have been studied with [ 11 C]NMSP in schizophrenia patients, while studies of another serotonin receptor subtype, 5-HT 1A receptors, have been mainly conducted in patients with depression. [ 11 C]NMSP PET showed no difference between schizophrenia patients who had not undergone phamacotherapy and normal subjects. Because serotonin selective reuptake inhibitors (SSRIs) affect serotonin transporters, and abnormalities in serotonin transporters detected in mood disorders, PET ligands for serotonin transporters have increasingly been developed, and serotonin transporters have recently begun to be

  14. Automatic extraction of forward stroke volume using dynamic PET/CT: a dual-tracer and dual-scanner validation in patients with heart valve disease.

    Science.gov (United States)

    Harms, Hendrik Johannes; Tolbod, Lars Poulsen; Hansson, Nils Henrik Stubkjær; Kero, Tanja; Orndahl, Lovisa Holm; Kim, Won Yong; Bjerner, Tomas; Bouchelouche, Kirsten; Wiggers, Henrik; Frøkiær, Jørgen; Sörensen, Jens

    2015-12-01

    The aim of this study was to develop and validate an automated method for extracting forward stroke volume (FSV) using indicator dilution theory directly from dynamic positron emission tomography (PET) studies for two different tracers and scanners. 35 subjects underwent a dynamic (11)C-acetate PET scan on a Siemens Biograph TruePoint-64 PET/CT (scanner I). In addition, 10 subjects underwent both dynamic (15)O-water PET and (11)C-acetate PET scans on a GE Discovery-ST PET/CT (scanner II). The left ventricular (LV)-aortic time-activity curve (TAC) was extracted automatically from PET data using cluster analysis. The first-pass peak was isolated by automatic extrapolation of the downslope of the TAC. FSV was calculated as the injected dose divided by the product of heart rate and the area under the curve of the first-pass peak. Gold standard FSV was measured using phase-contrast cardiovascular magnetic resonance (CMR). FSVPET correlated highly with FSVCMR (r = 0.87, slope = 0.90 for scanner I, r = 0.87, slope = 1.65, and r = 0.85, slope = 1.69 for scanner II for (15)O-water and (11)C-acetate, respectively) although a systematic bias was observed for both scanners (p dynamic PET/CT and cluster analysis. Results are almost identical for (11)C-acetate and (15)O-water. A scanner-dependent bias was observed, and a scanner calibration factor is required for multi-scanner studies. Generalization of the method to other tracers and scanners requires further validation.

  15. Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype.

    Science.gov (United States)

    Catana, Ciprian; van der Kouwe, Andre; Benner, Thomas; Michel, Christian J; Hamm, Michael; Fenchel, Matthias; Fischl, Bruce; Rosen, Bruce; Schmand, Matthias; Sorensen, A Gregory

    2010-09-01

    Several factors have to be considered for implementing an accurate attenuation-correction (AC) method in a combined MR-PET scanner. In this work, some of these challenges were investigated, and an AC method based entirely on the MRI data obtained with a single dedicated sequence was developed and used for neurologic studies performed with the MR-PET human brain scanner prototype. The focus was on the problem of bone-air segmentation, selection of the linear attenuation coefficient for bone, and positioning of the radiofrequency coil. The impact of these factors on PET data quantification was studied in simulations and experimental measurements performed on the combined MR-PET scanner. A novel dual-echo ultrashort echo time (DUTE) MRI sequence was proposed for head imaging. Simultaneous MR-PET data were acquired, and the PET images reconstructed using the proposed DUTE MRI-based AC method were compared with the PET images that had been reconstructed using a CT-based AC method. Our data suggest that incorrectly accounting for the bone tissue attenuation can lead to large underestimations (>20%) of the radiotracer concentration in the cortex. Assigning a linear attenuation coefficient of 0.143 or 0.151 cm(-1) to bone tissue appears to give the best trade-off between bias and variability in the resulting images. Not identifying the internal air cavities introduces large overestimations (>20%) in adjacent structures. On the basis of these results, the segmented CT AC method was established as the silver standard for the segmented MRI-based AC method. For an integrated MR-PET scanner, in particular, ignoring the radiofrequency coil attenuation can cause large underestimations (i.e., PET field of view has to be accurately known. High-quality bone-air segmentation can be performed using the DUTE data. The PET images obtained using the DUTE MRI- and CT-based AC methods compare favorably in most of

  16. The Dedicated Aerosol Retrieval Experiment (DARE): scientific requirements for a dedicated satellite instrument to measure atmospheric aerosols

    NARCIS (Netherlands)

    Decae, R.; Courrèges-Lacoste, G.B.; Leeuw, G. de

    2004-01-01

    DARE (Dedicated Aerosol Retrieval Experiment) is a study to design an instrument for accurate remote sensing of aerosol properties from space. DARE combines useful properties of several existing instruments like TOMS, GOME, ATSR and POLDER. It has a large wavelength range, 330 to 1000 nm, to

  17. Comparison between a dual-head and a brain-dedicated SPECT system in the measurement of the loss of dopamine transporters with [123I]FP-CIT

    International Nuclear Information System (INIS)

    Varrone, Andrea; Sansone, Valeria; Pappata, Sabina; Salvatore, Marco; Pellecchia, Maria T.; Salvatore, Elena; de Michele, Giuseppe; Filla, Alessandro; Barone, Paolo; Amboni, Marianna

    2008-01-01

    Dual-head SPECT systems are used by many clinical departments for [ 123 I]FP-CIT SPECT imaging, while triple-head or brain-dedicated systems with better imaging performance are more commonly used by research institutions. There are limited data comparing the capability of the two types of system to measure dopamine transporter (DAT) loss in vivo. The aim of this study was to compare the ability of a dual-head and a brain-dedicated SPECT system to estimate the degree of DAT loss in different movement disorders with variable nigrostriatal impairment, with [ 123 I]FP-CIT. Four patients with essential tremor, 24 with Parkinson's disease (PD), six with spinocerebellar ataxia type 2 and six controls were studied with [ 123 I]FP-CIT. SPECT scans were performed on a dual-head (E.CAM - Siemens) and subsequently on a brain-dedicated system (Ceraspect - DSI). Striatal DAT outcome measures on the E.CAM and the Ceraspect were strongly correlated and the putamen-to-caudate ratios were almost identical. Although the measured values were lower by 52 ± 25% in caudate and by 51 ± 31% in putamen on the E.CAM (p < 0.0001), the average striatal DAT decrease in each patient group compared with controls was similar for both systems. In PD patients, similar correlations (p < 0.05) were found between motor UPDRS or Hoehn and Yahr stage and striatal DAT density. Despite underestimation of striatal DAT outcome measures, the E.CAM showed similar capability as the Ceraspect in measuring the degree of nigrostriatal dopaminergic deficit and assessing the correlation between DAT outcome measures and clinical variables of PD severity and stage. (orig.)

  18. Positron range in PET imaging: an alternative approach for assessing and correcting the blurring

    DEFF Research Database (Denmark)

    Jødal, Lars; Le Loirec, Cindy; Champion, Christophe

    2012-01-01

    Background: Positron range impairs resolution in PET imaging, especially for high-energy emitters and for small-animal PET. De-blurring in image reconstruction is possible if the blurring distribution is known. Further, the percentage of annihilation events within a given distance from the point...... on allowed-decay isotopes. Methods: It is argued that blurring at the detection level should not be described by positron range r, but instead the 2D-projected distance δ (equal to the closest distance between decay and line-of-response). To determine these 2D distributions, results from a dedicated positron...... is important for improved resolution in PET imaging. Relevant distributions for positron range have been derived for seven isotopes. Distributions for other allowed-decay isotopes may be estimated with the above formulas....

  19. Gamma camera based FDG PET in oncology

    International Nuclear Information System (INIS)

    Park, C. H.

    2002-01-01

    Positron Emission Tomography(PET) was introduced as a research tool in the 1970s and it took about 20 years before PET became an useful clinical imaging modality. In the USA, insurance coverage for PET procedures in the 1990s was the turning point, I believe, for this progress. Initially PET was used in neurology but recently more than 80% of PET procedures are in oncological applications. I firmly believe, in the 21st century, one can not manage cancer patients properly without PET and PET is very important medical imaging modality in basic and clinical sciences. PET is grouped into 2 categories; conventional (c) and gamma camera based ( CB ) PET. CB PET is more readily available utilizing dual-head gamma cameras and commercially available FDG to many medical centers at low cost to patients. In fact there are more CB PET in operation than cPET in the USA. CB PET is inferior to cPET in its performance but clinical studies in oncology is feasible without expensive infrastructures such as staffing, rooms and equipments. At Ajou university Hospital, CBPET was installed in late 1997 for the first time in Korea as well as in Asia and the system has been used successfully and effectively in oncological applications. Our was the fourth PET operation in Korea and I believe this may have been instrumental for other institutions got interested in clinical PET. The following is a brief description of our clinical experience of FDG CBPET in oncology

  20. Demonstration of an Axial PET concept for brain and small animal imaging

    CERN Document Server

    Beltrame, P; Clinthorne, N; Meddi, F; Kagan, H; Braem, A; Pauss, F; Djambazov, L; Lustermann, W; Weilhammer, P; Nessi-Tedaldi, F; Dissertori, G; Renker, D; Schneider, T; Schinzel, D; De Leo, R; Bolle, E; Fanti, V; Rafecas, M; Rudge, A; Stapnes, S; Casella, C; Chesi, E; Seguinot, J; Solevi, P; Joram, C; Oliver, J F

    2011-01-01

    Standard Positron Emission Tomography (PET) cameras need to reach a compromise between spatial resolution and sensitivity. To overcome this limitation we developed a novel concept of PET. Our AX-PET demonstrator is made of LYSO crystals aligned along the z coordinate (patient's axis) and WLS strips orthogonally placed with respect to the crystals. This concept offers full 3D localization of the photon interaction inside the camera. Thus the spatial resolution and the sensitivity can be simultaneously improved and the reconstruction of Compton interactions inside the detector is also possible. Moreover, by means of G-APDs for reading out the photons, both from LYSO and WLS, the detector is insensitive to magnetic fields and it is then suitable to be used in a combined PET/MRI apparatus. A complete Monte Carlo simulation and dedicated reconstruction software have been developed. The two final modules, each composed of 48 crystals and 156 WLS strips, have been built and fully characterized in a dedicated test se...

  1. A small animal PET prototype based on Silicon Photomultipliers

    International Nuclear Information System (INIS)

    Marcatili, S; Belcari, N.; Bisogni, M.G.; Del Guerra, A.; Collazuol, G.; Pedreschi, E.; Spinella, F.; Sportelli, G.; Marzocca, C.

    2011-01-01

    Next generation PET scanners should full fill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultiplier (Si P M) matrices is proposed for the construction of a small animal PET system consisting of two detector heads based on Lyso continuos crystals. The use of large area multi-pixel Silicon Photomultiplier (Si P M) detectors requires the development of a multichannel Digital Acquisition system (DAQ) as well as of a dedicated front-end in order not to degrade the intrinsic detector capabilities. At the University of Pisa and INFN Pisa we developed a DAQ board for the read-out of 2 64-pixel Si P M matrices in time coincidence for Positron Emission Tomography (PET) applications. The proof of principles is based on 64-pixel detectors, but the whole system has been conceived to be easily scalable to a higher number of channels. Here we describe the Group-V INFN DASi P M 2 (Development and Application of Si P M) project and related results.

  2. Silicon Photomultipliers (SiPM) as novel photodetectors for PET

    International Nuclear Information System (INIS)

    Del Guerra, Alberto; Belcari, Nicola; Giuseppina Bisogni, Maria; Corsi, Francesco; Foresta, Maurizio; Guerra, Pedro; Marcatili, Sara; Santos, Andres; Sportelli, Giancarlo

    2011-01-01

    Next generation PET scanners should fulfill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultipliers (SiPMs) is proposed for the construction of a 4D-PET module of 4.8x4.8 cm 2 aimed to replace the standard PMT based PET block detector. The module will be based on a LYSO continuous crystal read on two faces by Silicon Photomultipliers. A high granularity detection surface made by SiPM matrices of 1.5 mm pitch will be used for the x-y photon hit position determination with submillimetric accuracy, while a low granularity surface constituted by 16 mm 2 SiPM pixels will provide the fast timing information (t) that will be used to implement the Time of Flight technique (TOF). The spatial information collected by the two detector layers will be combined in order to measure the Depth of Interaction (DOI) of each event (z). The use of large area multi-pixel Silicon Photomultiplier (SiPM) detectors requires the development of a multichannel Data Acquisition system (DAQ) as well as of a dedicated front-end in order not to degrade the intrinsic detector capabilities and to manage many channels. The paper describes the progress made on the development of the proof of principle module under construction at the University of Pisa.

  3. External radioactive markers for PET data-driven respiratory gating in positron emission tomography.

    Science.gov (United States)

    Büther, Florian; Ernst, Iris; Hamill, James; Eich, Hans T; Schober, Otmar; Schäfers, Michael; Schäfers, Klaus P

    2013-04-01

    Respiratory gating is an established approach to overcoming respiration-induced image artefacts in PET. Of special interest in this respect are raw PET data-driven gating methods which do not require additional hardware to acquire respiratory signals during the scan. However, these methods rely heavily on the quality of the acquired PET data (statistical properties, data contrast, etc.). We therefore combined external radioactive markers with data-driven respiratory gating in PET/CT. The feasibility and accuracy of this approach was studied for [(18)F]FDG PET/CT imaging in patients with malignant liver and lung lesions. PET data from 30 patients with abdominal or thoracic [(18)F]FDG-positive lesions (primary tumours or metastases) were included in this prospective study. The patients underwent a 10-min list-mode PET scan with a single bed position following a standard clinical whole-body [(18)F]FDG PET/CT scan. During this scan, one to three radioactive point sources (either (22)Na or (18)F, 50-100 kBq) in a dedicated holder were attached the patient's abdomen. The list mode data acquired were retrospectively analysed for respiratory signals using established data-driven gating approaches and additionally by tracking the motion of the point sources in sinogram space. Gated reconstructions were examined qualitatively, in terms of the amount of respiratory displacement and in respect of changes in local image intensity in the gated images. The presence of the external markers did not affect whole-body PET/CT image quality. Tracking of the markers led to characteristic respiratory curves in all patients. Applying these curves for gated reconstructions resulted in images in which motion was well resolved. Quantitatively, the performance of the external marker-based approach was similar to that of the best intrinsic data-driven methods. Overall, the gain in measured tumour uptake from the nongated to the gated images indicating successful removal of respiratory motion

  4. Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

    Energy Technology Data Exchange (ETDEWEB)

    Oehmigen, Mark, E-mail: mark.oehmigen@uni-due.de; Lindemann, Maike E. [High Field and Hybrid MR Imaging, University Hospital Essen, Essen 45147 (Germany); Lanz, Titus [Rapid Biomedical GmbH, Rimpar 97222 (Germany); Kinner, Sonja [Institute for Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen 45147 (Germany); Quick, Harald H. [High Field and Hybrid MR Imaging, University Hospital Essen, Essen 45147, Germany and Erwin L. Hahn Institute for MR Imaging, University Duisburg-Essen, Essen 45141 (Germany)

    2016-08-15

    Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating and applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at

  5. Neuropsychiatry: PET and SPECT

    International Nuclear Information System (INIS)

    Quintana F, Juan Carlos

    2002-01-01

    Functional brain imaging with PET and SPECT have a definitive and well established role in the investigation of a variety of conditions such as dementia, epilepsy and drug addiction. With these methods it is possible to detect early rCBF (regional Cerebral Blood Flow) changes seen in dementia (even before clinical symptoms) and differentiate Alzheimer's disease from other dementias by means of the rCBF pattern change. 18-F-FDG PET imaging is a useful tool in partial epilepsy because both rCBF and brain metabolism are compromised at the epileptogenic focus. During the seizure, rCBF dramatically increases locally. Using SPECT it is possible to locate such foci with 97% accuracy. In drug addiction, particularly with cocaine, functional imaging has proven to be very sensitive to detect brain flow and metabolism derangement early in the course of this condition. These findings are important in many ways: prognostic value, they are used as a powerful reinforcement tool and to monitor functional recovery with rehabilitation. There are many other conditions in which functional brain imaging is of importance such as acute stroke treatment assessment, trauma rehabilitation and in psychiatric and abnormal movement diseases specially with the development of receptor imaging (au)