WorldWideScience

Sample records for dedicated pet camera

  1. Gamma-camera 18F-FDG PET in diagnosis and staging of patients presenting with suspected lung cancer and comparison with dedicated PET

    DEFF Research Database (Denmark)

    Oturai, Peter S; Mortensen, Jann; Enevoldsen, Henriette

    2004-01-01

    It is not clear whether high-quality coincidence gamma-PET (gPET) cameras can provide clinical data comparable with data obtained with dedicated PET (dPET) cameras in the primary diagnostic work-up of patients with suspected lung cancer. This study focuses on 2 main issues: direct comparison...

  2. Value of coincidence gamma camera PET for diagnosing head and neck tumors: functional imaging and image coregistration

    International Nuclear Information System (INIS)

    Dresel, S.; Brinkbaeumer, K.; Schmid, R.; Hahn, K.

    2001-01-01

    54 patients suffering from head and neck tumors (30 m, 24 f, age: 32-67 years) were examined using dedicated PET and coincidence gamma camera PET after injection of 185-350 MBq [ 18 F]FDG. Examinations were carried out on the dedicated PET first (Siemens ECAT Exact HR+) followed by a scan on the coincidence gamma camera PET (Picker Prism 2000 XP-PCD, Marconi Axis g-PET 2 AZ). Dedicated PET was acquired in 3D mode, coincidence gamma camera PET was performed in list mode using an axial filter. Reconstruction of data was performed iteratively on both, dedicated PET and coincidence gamma camera PET. All patients received a CT scan in multislice technique (Siemens Somatom Plus 4, Marconi MX 8000). Image coregistration was performed on an Odyssey workstation (Marconi). All findings have been verified by the gold standard histology or in case of negative histology by follow-up. Results: Using dedicated PET the primary or recurrent lesion was correctly diagnosed in 47/48 patients, using coincidence gamma camera PET in 46/48 patients and using CT in 25/48 patients. Metastatic disease in cervical lymph nodes was diagnosed in 17/18 patients with dedicated PET, in 16/18 patients with coincidence gamma camera PET and in 15/18 with CT. False-positive results with regard to lymph node metastasis were seen with one patient for dedicated PET and hybrid PET, respectively, and with 18 patients for CT. In a total of 11 patients unknown metastatic lesions were seen with dedicated PET and with coincidence gamma camera PET elsewhere in the body (lung: n = 7, bone: n = 3, liver: n = 1). Additional malignant disease other than the head and neck tumor was found in 4 patients. (orig.) [de

  3. PET with a dual-head coincidence gamma camera in head and neck cancer: A comparison with computed tomography and dedicated PET

    International Nuclear Information System (INIS)

    Zimny, M.

    2001-01-01

    Positron emission tomography with 18 F-fluoro-deoxyglucose (FDG PET) is a promising imaging tool for detecting and staging of primary or recurrent head and neck cancer. The aim of this study was to evaluate a dual-head gamma camera modified for coincidence detection (KGK-PET) in comparison to computed tomography (CT) and dedicated PET (dPET). 50 patients with known or suspected primary or recurrent head and neck cancer were enrolled. 32 patients underwent KGK-PET and dPET using a one-day protocol. The sensitivity for the detection of primary/ recurrent head and neck cancer for KGK-PET and CT was 80% and 54%, respectively, specificity was 73% and 82%, respectively. The sensitivity and specificity for the detection of lymph node metastases based on neck sides with KGK-PET was 71% (CT: 65%) and 88% (CT: 89%) respectively. In comparison to dPET, KGK-PET revealed concordant results in 32/32 patients with respect to primary tumor/recurrent disease and in 55/60 evaluated neck sides. All involved neck sides that were missed by KGK-PET were also negative with dPET. These results indicate that in patients with head and neck cancer KGK-PET reveals information, that are similar to dPET and complementary to CT. (orig.) [de

  4. Performance evaluation of a high resolution dedicated breast PET scanner

    Energy Technology Data Exchange (ETDEWEB)

    García Hernández, Trinitat, E-mail: mtrinitat@eresa.com; Vicedo González, Aurora; Brualla González, Luis; Granero Cabañero, Domingo [Department of Medical Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Ferrer Rebolleda, Jose; Sánchez Jurado, Raúl; Puig Cozar Santiago, Maria del [Department of Nuclear Medicine, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Roselló Ferrando, Joan [Department of Medical Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Department of Physiology, University of Valencia, Valencia 46010 (Spain)

    2016-05-15

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ({sup 18}F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good

  5. Performance evaluation of a high resolution dedicated breast PET scanner

    International Nuclear Information System (INIS)

    García Hernández, Trinitat; Vicedo González, Aurora; Brualla González, Luis; Granero Cabañero, Domingo; Ferrer Rebolleda, Jose; Sánchez Jurado, Raúl; Puig Cozar Santiago, Maria del; Roselló Ferrando, Joan

    2016-01-01

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ("1"8F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good performance

  6. Progress on dedicated animal PET

    International Nuclear Information System (INIS)

    Liu Wei

    2002-01-01

    Positron emission tomography, as the leading technology providing molecular imaging of biological processes, is widely used on living laboratory animals. High-resolution dedicated animal PET scanners have been developed. Although the dedicated animal PET faces obstacles and challenges, this advanced technology would play an important role in molecular biomedicine researches, such as diseases study, medicine development, and gene therapy

  7. [F-18]FDG imaging of head and neck tumors: comparison of hybrid PET, dedicated PET and CT

    International Nuclear Information System (INIS)

    Dresel, S.; Brinkbaeumer, K.; Schmid, R.; Poepperl, G.; Hahn, K.; Szeimies, U.

    2001-01-01

    Aim: Aim of the study was to evaluate [F-18]FDG imaging of head and neck tumors using a Hybrid-PET device of the 2nd or 3rd generation. Examinations were compared to dedicated PET and Spiral-CT. Methods: 54 patients suffering from head and neck tumors were examined using dedicated PET and Hybrid-PET after injection of 185-350 MBq [F-18]FDG. Examinations were carried out on the dedicated PET first followed by a scan on the Hybrid-PET. Dedicated PET was acquired in 3D mode, Hybrid-PET was performed in list mode using an axial filter. Reconstruction of data was performed iteratively on both, dedicated PET and Hybrid-PET. All patients received a CT scan in multislice technique. All finding have been verified by the goldstandard histology or in case of negative histology by follow up. Results: Using dedicated PET the primary or recurrent lesion was correctly diagnosed in 47/48 patients, using Hybrid-PET in 46/48 patients and using CT in 25/48 patients. Metastatic disease in cervical lymph nodes was diagnosed in 17/18 patients with dedicated PET, in 16/18 patients with Hybrid-PET and in 15/18 with CT. False positive results with regard to lymph node metastasis were seen with one patient for dedicated PET and Hybrid-PET, respectively, and with 18 patients for CT. In a total of 11 patients unknown metastastic lesions were seen with dedicated PET and with Hybrid-PET elsewhere in the body. Additional malignant disease other than the head and neck tumor was found in 4 patients. Conclusion: Using Hybrid-PET for [F-18]FDG imaging reveals a loss of sensitivity and specificity of about 1-5% as compared to dedicated PET in head and neck tumors. [F-18]FDG PET with both, dedicated PET and Hybrid-PET is superior to CT in the diagnosis of primary or recurrent lesions as well as in the assessment of lymph node involvement. (orig.) [de

  8. Molecular Imaging in Breast Cancer: From Whole-Body PET/CT to Dedicated Breast PET

    Directory of Open Access Journals (Sweden)

    B. B. Koolen

    2012-01-01

    Full Text Available Positron emission tomography (PET, with or without integrated computed tomography (CT, using 18F-fluorodeoxyglucose (FDG is based on the principle of elevated glucose metabolism in malignant tumors, and its use in breast cancer patients is frequently being investigated. It has been shown useful for classification, staging, and response monitoring, both in primary and recurrent disease. However, because of the partial volume effect and limited resolution of most whole-body PET scanners, sensitivity for the visualization of small tumors is generally low. To improve the detection and quantification of primary breast tumors with FDG PET, several dedicated breast PET devices have been developed. In this nonsystematic review, we shortly summarize the value of whole-body PET/CT in breast cancer and provide an overview of currently available dedicated breast PETs.

  9. Characterization of a PET Camera Optimized for Prostate Imaging

    International Nuclear Information System (INIS)

    Huber, Jennifer S.; Choong, Woon-Seng; Moses, William W.; Qi, Jinyi; Hu, Jicun; Wang, G.C.; Wilson, David; Oh, Sang; Huesman, RonaldH.; Derenzo, Stephen E.

    2005-01-01

    We present the characterization of a positron emission tomograph for prostate imaging that centers a patient between a pair of external curved detector banks (ellipse: 45 cm minor, 70 cm major axis). The distance between detector banks adjusts to allow patient access and to position the detectors as closely as possible for maximum sensitivity with patients of various sizes. Each bank is composed of two axial rows of 20 HR+ block detectors for a total of 80 detectors in the camera. The individual detectors are angled in the transaxial plane to point towards the prostate to reduce resolution degradation in that region. The detectors are read out by modified HRRT data acquisition electronics. Compared to a standard whole-body PET camera, our dedicated-prostate camera has the same sensitivity and resolution, less background (less randoms and lower scatter fraction) and a lower cost. We have completed construction of the camera. Characterization data and reconstructed images of several phantoms are shown. Sensitivity of a point source in the center is 946 cps/mu Ci. Spatial resolution is 4 mm FWHM in the central region

  10. Detector design issues for compact nuclear emission cameras dedicated to breast imaging

    International Nuclear Information System (INIS)

    Levin, Craig S.

    2003-01-01

    Certain gamma ray and positron emitting radiotracers have shown great promise for use in the detection, diagnosis and staging of breast cancer. Unfortunately, standard nuclear emission cameras (SPECT, PET) found in the clinic are not practical for breast imaging of these emissions due to inadequate spatial and energy resolutions and sensitivity, large and awkward size, and relatively high cost per study. High spatial and energy resolutions and sensitivity are needed for good lesion detectability. Due to these limitations of standard cameras, there has been recent research into the development of small, compact nuclear emission imagers dedicated for close-proximity breast imaging. The small detector head size means a variety of exotic detectors or collimators may be implemented to improve spatial and energy resolution and sensitivity performances at a reasonable cost. In this paper, we will present some of the compact gamma ray and annihilation photon imaging detector designs that have been proposed and/or developed for dedicated breast imaging. We will review the physics and discuss the advantages and disadvantages of various detector configurations. Finally we will estimate the fundamental spatial resolution potential available with close-proximity nuclear emission imaging and discuss how one may approach those limits through proper detector design

  11. Evaluation of a video-based head motion tracking system for dedicated brain PET

    Science.gov (United States)

    Anishchenko, S.; Beylin, D.; Stepanov, P.; Stepanov, A.; Weinberg, I. N.; Schaeffer, S.; Zavarzin, V.; Shaposhnikov, D.; Smith, M. F.

    2015-03-01

    Unintentional head motion during Positron Emission Tomography (PET) data acquisition can degrade PET image quality and lead to artifacts. Poor patient compliance, head tremor, and coughing are examples of movement sources. Head motion due to patient non-compliance can be an issue with the rise of amyloid brain PET in dementia patients. To preserve PET image resolution and quantitative accuracy, head motion can be tracked and corrected in the image reconstruction algorithm. While fiducial markers can be used, a contactless approach is preferable. A video-based head motion tracking system for a dedicated portable brain PET scanner was developed. Four wide-angle cameras organized in two stereo pairs are used for capturing video of the patient's head during the PET data acquisition. Facial points are automatically tracked and used to determine the six degree of freedom head pose as a function of time. The presented work evaluated the newly designed tracking system using a head phantom and a moving American College of Radiology (ACR) phantom. The mean video-tracking error was 0.99±0.90 mm relative to the magnetic tracking device used as ground truth. Qualitative evaluation with the ACR phantom shows the advantage of the motion tracking application. The developed system is able to perform tracking with accuracy close to millimeter and can help to preserve resolution of brain PET images in presence of movements.

  12. Dedicated brain PET system of PET/MR for brain research

    International Nuclear Information System (INIS)

    Cheng, Li; Liu, Yaqiang; Ma, Tianyu; Wang, Shi; Wei, Qingyang; Xu, Tianpeng

    2015-01-01

    This work is to replace PET ring in human brain PET/MR system with a dedicated wearable PET insert, aimed at improving both patient feasibility and system performance for brain imaging. The designed PET/MR system includes two parts: the inside parts, including a radio frequency (RF) coil and PET ring, are mounted on patient’s head, and the outside part, a MR imager, is dependent of patient. The RF coil is the innermost layer, surrounded by an outer PET-ring layer. They are supported by a MRcompatible structure. And both RF coil and PET detectors are placed inside a standard clinical 3-T MR imager. From the design of the system we can infer that some advantages can be achieved. First, high sensitivity will be achieved with the same amount crystals as the PET ring is more close to region-of-interest area, at a reduced cost. Second, by using a 2-layer depth of interaction (DOI) detector, the parallax effect can be minimized. The resolution will benefit from short positron range caused by magnetic field and smaller ring diameter will also reduce the effect of non-collinearity. Thirdly, as the PET ring is mounted on head, impact of patient motion will be reduced.

  13. Dedicated brain PET system of PET/MR for brain research

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Li; Liu, Yaqiang; Ma, Tianyu; Wang, Shi; Wei, Qingyang; Xu, Tianpeng [Institute of Medical Physics, Department of Engineering Physics, Tsinghua University, Beijing (China)

    2015-05-18

    This work is to replace PET ring in human brain PET/MR system with a dedicated wearable PET insert, aimed at improving both patient feasibility and system performance for brain imaging. The designed PET/MR system includes two parts: the inside parts, including a radio frequency (RF) coil and PET ring, are mounted on patient’s head, and the outside part, a MR imager, is dependent of patient. The RF coil is the innermost layer, surrounded by an outer PET-ring layer. They are supported by a MRcompatible structure. And both RF coil and PET detectors are placed inside a standard clinical 3-T MR imager. From the design of the system we can infer that some advantages can be achieved. First, high sensitivity will be achieved with the same amount crystals as the PET ring is more close to region-of-interest area, at a reduced cost. Second, by using a 2-layer depth of interaction (DOI) detector, the parallax effect can be minimized. The resolution will benefit from short positron range caused by magnetic field and smaller ring diameter will also reduce the effect of non-collinearity. Thirdly, as the PET ring is mounted on head, impact of patient motion will be reduced.

  14. Positron emission tomography with gamma camera in coincidence mode

    International Nuclear Information System (INIS)

    Hertel, A.; Hoer, G.

    1999-01-01

    Positron emission tomography using F-18 FDG has been estbalished in clinical diagnostics with first indications especially in oncology. To install a conventional PET tomography (dedicated PET) is financially costly and restricted to PET examinations only. Increasing demand for PET diagnostics on one hand and restricted financial resources in the health system on the other hand led industry to develop SPECT cameras to be operated in coincidence mode (camera PET) in order to offer nuclear medicine physicians cost-effective devices for PET diagnostic. At the same time camera PET is inferior to conventional PET regarding sensitivity and detection-efficiency for 511 keV photons. Does camera-PET offer a reliable alternative to conventional PET? The first larger comparative studies are now available, so a first apraisal about the technical clinical performance of camera-PET can be done. (orig.) [de

  15. Gamma camera based FDG PET in oncology

    International Nuclear Information System (INIS)

    Park, C. H.

    2002-01-01

    Positron Emission Tomography(PET) was introduced as a research tool in the 1970s and it took about 20 years before PET became an useful clinical imaging modality. In the USA, insurance coverage for PET procedures in the 1990s was the turning point, I believe, for this progress. Initially PET was used in neurology but recently more than 80% of PET procedures are in oncological applications. I firmly believe, in the 21st century, one can not manage cancer patients properly without PET and PET is very important medical imaging modality in basic and clinical sciences. PET is grouped into 2 categories; conventional (c) and gamma camera based ( CB ) PET. CB PET is more readily available utilizing dual-head gamma cameras and commercially available FDG to many medical centers at low cost to patients. In fact there are more CB PET in operation than cPET in the USA. CB PET is inferior to cPET in its performance but clinical studies in oncology is feasible without expensive infrastructures such as staffing, rooms and equipments. At Ajou university Hospital, CBPET was installed in late 1997 for the first time in Korea as well as in Asia and the system has been used successfully and effectively in oncological applications. Our was the fourth PET operation in Korea and I believe this may have been instrumental for other institutions got interested in clinical PET. The following is a brief description of our clinical experience of FDG CBPET in oncology

  16. Usefulness of FDG PET for nodal staging using a dual head coincidence camera in patients with lung cancer

    International Nuclear Information System (INIS)

    Yoon, Seok Nam; Park, Chan H.; Lee, Myoung Hoon; Hwang, Kyung Hoon; Hwang, Kyung Hoon

    2001-01-01

    Staging of lung cancer requires an accurate evaluation of the mediastinum. Positron imaging with dual head cameras may be not as sensitive as dedicated PET. Therefore, the purpose of the study was to evaluated the usefulness of F-18 FDG coincidence (CoDe) PET using a dual-head gamma camera in the nodal staging of the lung cancer. CoDe-PET studies were performed in 51 patients with histologically proven non small cell lung cancer. CoDe-PET began 60 minutes after the injection of 111-185 MBq of F-18 FDG. CoDe-PET was performed using a dual-head gamma camera equipped with coincidence detection circuitry (Elscints Varicam, Haifa, lsrael). There was no attenuation correction made and reconstruction was done using a filtered back-projection. Surgery was performed in 49 patients CoDe-PET studies were evaluated visually. Any focal increased uptake was considered abnormal. The nodal stating of CoDe-PET studies were evaluated visually. Any focal increased uptake was considered abnormal. The nodal staging of CoDe-PET and of CT were compared with the nodal stating of surgical (49) and mediastinoscopical (2) pathology. All primary lung lesions were hypermetabolic and easily visualized. Compared with surgical nodal staging as a gold standard, false positives occurred in 13 CoDe PET and 17 CT studies and false negative occurred in 5 CoDe-PET and 4 CT studies. Assessment of lymph node involvement by CoDe-PET depicted a sensitivity of 67%, specificity of 64% and accuracy of 65%. CT revealed a sensitivity of 73%, specificity of 53% and accuracy of 59% in the assessment of lymph node involvement. The detection of primary lesions were 100% but nodal staging was suboptimal for routine clinical use. This is mainly due to limited resolution of our system

  17. A dedicated breast-PET/CT scanner: Evaluation of basic performance characteristics.

    Science.gov (United States)

    Raylman, Raymond R; Van Kampen, Will; Stolin, Alexander V; Gong, Wenbo; Jaliparthi, Gangadhar; Martone, Peter F; Smith, Mark F; Sarment, David; Clinthorne, Neal H; Perna, Mark

    2018-04-01

    Application of advanced imaging techniques, such as PET and x ray CT, can potentially improve detection of breast cancer. Unfortunately, both modalities have challenges in the detection of some lesions. The combination of the two techniques, however, could potentially lead to an overall improvement in diagnostic breast imaging. The purpose of this investigation is to test the basic performance of a new dedicated breast-PET/CT. The PET component consists of a rotating pair of detectors. Its performance was evaluated using the NEMA NU4-2008 protocols. The CT component utilizes a pulsed x ray source and flat panel detector mounted on the same gantry as the PET scanner. Its performance was assessed using specialized phantoms. The radiation dose to a breast during CT imaging was explored by the measurement of free-in-air kerma and air kerma measured at the center of a 16 cm-diameter PMMA cylinder. Finally, the combined capabilities of the system were demonstrated by imaging of a micro-hot-rod phantom. Overall, performance of the PET component is comparable to many pre-clinical and other dedicated breast-PET scanners. Its spatial resolution is 2.2 mm, 5 mm from the center of the scanner using images created with the single-sliced-filtered-backprojection algorithm. Peak NECR is 24.6 kcps; peak sensitivity is 1.36%; the scatter fraction is 27%. Spatial resolution of the CT scanner is 1.1 lp/mm at 10% MTF. The free-in-air kerma is 2.33 mGy, while the PMMA-air kerma is 1.24 mGy. Finally, combined imaging of a micro-hot-rod phantom illustrated the potential utility of the dual-modality images produced by the system. The basic performance characteristics of a new dedicated breast-PET/CT scanner are good, demonstrating that its performance is similar to current dedicated PET and CT scanners. The potential value of this system is the capability to produce combined duality-modality images that could improve detection of breast disease. The next stage in development of this system

  18. Design and evaluation of the MAMMI dedicated breast PET

    International Nuclear Information System (INIS)

    Moliner, L.; González, A. J.; Soriano, A.; Sánchez, F.; Correcher, C.; Orero, A.; Carles, M.; Vidal, L. F.; Barberá, J.; Caballero, L.; Seimetz, M.; Vázquez, C.; Benlloch, J. M.

    2012-01-01

    Purpose: A breast dedicated positron emission tomography (PET) scanner has been developed based on monolithic LYSO crystals coupled to position sensitive photomultiplier tubes (PSPMTs). In this study, we describe the design of the PET system and report on its performance evaluation. Methods: MAMMI is a breast PET scanner based on monolithic LYSO crystals. It consists of 12 compact modules with a transaxial field of view (FOV) of 170 mm in diameter and 40 mm axial FOV that translates to cover up to 170 mm. The patient lies down in a prone position that facilitates maximum breast elongation. Quantitative performance analysis of the calculated method for the attenuation correction specifically developed for MAMMI, and based on PET image segmentation, has also been conducted in this evaluation. In order to fully determine the MAMMI prototype's performance, we have adapted the measurements suggested for National Electrical Manufacturers Association (NEMA) NU 2-2007 and NU 4-2008 protocol tests, as they are defined for whole-body and small animal PET scanners, respectively. Results: Spatial resolutions of 1.6, 1.8, and 1.9 mm were measured in the axial, radial, and tangential directions, respectively. A scatter fraction of 20.8% was obtained and the maximum NEC was determined to be 25 kcps at 44 MBq. The average sensitivity of the system was observed to be 1% for an energy window of (250 keV–750 keV) and a maximum absolute sensitivity of 1.8% was measured at the FOV center. Conclusions: The overall performance of the MAMMI reported on this evaluation quantifies its ability to produce high quality PET images. Spatial resolution values below 3 mm were measured in most of the FOV. Only the radial component of spatial resolution exceeds the 3 mm at radial positions larger than 60 mm. This study emphasizes the need for standardized testing methodologies for dedicated breast PET systems similar to NEMA standards for whole-body and small animal PET scanners.

  19. Clear-PEM, a dedicated PET camera for mammography

    CERN Document Server

    Lecoq, P

    2002-01-01

    Preliminary results suggest that Positron Emission Mammography (PEM) can offer a noninvasive method for the diagnosis of breast cancer. Metabolic images from PEM contain unique information not available from conventional morphologic imaging techniques and aid in expeditiously establishing the diagnosis of cancer. A dedicated machine seems to offer better perspectives in terms of position resolution and sensitivity. This paper describes the concept of Clear-PEM, the system presently developed by the Crystal Clear Collaboration at CERN for an evaluation of this approach. This device is based on new crystals introduced by the Crystal Clear as well as on modern data acquisition techniques developed for the large experiments in high energy physics experiments.

  20. F-18 FDG PET with coincidence detection, dual-head gamma camera, initial experience in oncology

    Energy Technology Data Exchange (ETDEWEB)

    Chu, J.M.G.; Pocock, N.; Quach, T.; Camden, B.M.C. [Liverpool Health Services, Liverpool, NSW (Australia). Department of Nuclear Medicine and Clinical Ultrasound

    1998-06-01

    Full text: The development of Co-incidence Detection (CD) in gamma camera technology has allowed the use of positron radiopharmaceuticals in clinical practice without dedicated PET facilities. We report our initial experience of this technology in Oncological applications. All patients were administered 200 MBq of F- 18 FDG intravenously in a fasting state, with serum glucose below 8.9 mmol/L., and hydration well maintained. Tomography was performed using an ADAC Solus Molecular Co-incidence Detection (MCD) dual-head gamma camera, 60 minutes after administration and immediately after voiding. Tomography of the torso required up to three collections depending on the length of the patient, with each collection requiring 32 steps of 40 second duration, and a 50% overlap. Tomography of the brain required a single collection with 32 steps of 80 seconds. Patients were scanned in the supine position. An iterative reconstruction algorithm was employed without attenuation correction. All patients had histologically confirmed malignancy. Scan findings were correlated with results of all conventional diagnostic imaging procedures that were pertinent to the evaluation and management of each individual patient`s disease. Correlation with tumour type and treatment status was also undertaken. F-18 FDG uptake as demonstrated by CD-PET was increased in tumour bearing sites. The degree of increased uptake varied with tumour type and with treatment status. Our initial experience with CD-PET has been very encouraging, and has led us to undertake prospective short and long term studies to define its role in oncology

  1. A comparison of dedicated and hybrid PET imaging in detection of recurrences of colorectal cancer with [18]-FDG

    International Nuclear Information System (INIS)

    Montravers, F.; Grahek, D.; Kerrou, K.; Younsi, N.; Petegnief, Y.; Talbot, J.N.

    2002-01-01

    Full text: The aim of this study was to assess the clinical performances of FDG using a CDET system (hybrid dual-head MARCONI gamma camera with sodium iodine crystal 19 mm flick) or a dedicated PET system (C-PET, ADAC) for the detection of colorectal cancer recurrences. We report an experience of 4 years with CDET (July 1997 - July 2001) and of 1.5 years with PET (January 2000 - July 2001). After fasting for 6h or more, 3-5 MBq/kg (for 2D - CDET) or 2 MBq/kg (for 3D - PET) of [18F]-FDG were injected i.v. and imaging (whole-body scan and at least one tomoscintigram for CDET or scanning of the torso for PET) was started one hour later. Reconstruction was performed by an iterative algorithm. Attenuation correction by an external source was only available for PET. 304 examinations (ex) were performed with CDET and 164 with PET. 230 CDET cases and 73 PET cases are currently available according to histology or to follow-up. These examinations were performed for suspicion of recurrence (157 CDET cases, 39 PET cases), in search for other localization when one or more resectable lesion(s) was (were) known (48 CDET cases, 24 CDET cases) or for evaluation of the therapeutic efficacy (25 CDET cases, 10 PET cases). Globally, sensitivity was 89 % with CDET and 92 % with PET, specificity was 93 % with CDET and 100 % with PET and accuracy was 90 % with CDET and 93 % with PET. These results confirmed that FDG is a powerful tool for the detection of colorectal recurrences and showed that no significative difference in accuracy (chi2 = .75 ; p = .4) was detectable between the two modalities interpreted by the same team and both performed 1 hour after injection. (author)

  2. Development of a circular shape Si-PM-based detector ring for breast-dedicated PET system

    Science.gov (United States)

    Nakanishi, Kouhei; Yamamoto, Seiichi; Watabe, Hiroshi; Abe, Shinji; Fujita, Naotoshi; Kato, Katsuhiko

    2018-02-01

    In clinical situations, various breast-dedicated positron emission tomography (PET) systems have been used. However, clinical breast-dedicated PET systems have polygonal detector ring. Polygonal detector ring sometimes causes image artifact, so complicated reconstruction algorithm is needed to reduce artifact. Consequently, we developed a circular detector ring for breast-dedicated PET to obtain images without artifact using a simple reconstruction algorithm. We used Lu1.9Gd0.1SiO5 (LGSO) scintillator block which was made of 1.5 x 1.9 x 15 mm pixels that were arranged in an 8 x 24 matrix. As photodetectors, we used silicon photomultiplier (Si-PM) arrays whose channel size was 3 x 3 mm. A detector unit was composed of four scintillator blocks, 16 Si-PM arrays and a light guide. The developed detector unit had angled configuration since the light guide was bending. A detector unit had three gaps with an angle of 5.625° between scintillator blocks. With these configurations, we could arrange 64 scintillator blocks in nearly circular shape (regular 64-sided polygon) using 16 detector units. The use of the smaller number of detector units could reduce the size of the front-end electronics circuits. The inner diameter of the developed detector ring was 260 mm. This size was similar to those of brain PET systems, so our breast-dedicated PET detector ring can measure not only breast but also brain. Measured radial, tangential and axial spatial resolution of the detector ring reconstructed by the filtered back-projection (FBP) algorithm were 2.1 mm FWHM, 2.0 mm FWHM and 1.7 mm FWHM at center of field of view (FOV), respectively. The sensitivity was 2.0% at center of the axial FOV. With the developed detector ring, we could obtain high resolution image of the breast phantom and the brain phantom. We conclude that our developed Si-PM-based detector ring is promising for a high resolution breast-dedicated PET system that can also be used for brain PET system.

  3. Study of the personal radiation dose received by nuclear medicine technologists working in a dedicated PET centre

    International Nuclear Information System (INIS)

    Robinson, C.N.; Wallace, A.B.; Young, A.B.; Ibbetson, V.J.

    2005-01-01

    The use of dedicated PET scanners is becoming more widespread throughout Australia and the world. PET imaging utilises short-lived (-108 min), high-energy (511 keV) gamma-ray emitters, that could result in a high radiation dose being received by staff. As part of a larger staff and area monitoring project, this paper discusses the personal dose equivalent, H p (10), received by PET staff working in a dedicated PET centre. The typical H (10) received by staff was approximately 31 μSv. The average daily administered activity to patients at Austin Health was 1280 MBq

  4. PET with a coincidence gamma camera: results in selected oncological questions

    International Nuclear Information System (INIS)

    Lauer, I.; Haase, A; Adam, S.; Prueter, I.; Richter, E.; Baehre, M.

    2001-01-01

    Since early 1997, about 1660 investigations with coincidence gamma camera PET (CGC-PET) have been performed in our department, mostly undertaken for oncological questions. Based on these data, several retrospective and prospective studies were performed. In the following, the results in CUP (cancer of unknown primary) syndrome, melanoma and malignant lymphoma are presented. Methods: CGC-PET was performed after application of 250-350 MBq [ 18 F]FDG using a coincidence double head gamma camera with 19 mm Nal cristal. CUP-Syndrome: After completing conventional diagnostic procedures, 32 patients have been examined in a prospective study, including 25 patients with recently detected CUP and 7 patients undergoing restaging after therapy. Localization of the primary tumor was successful in 12 (38%) cases. Melanoma: We evaluated 50 studies in 41 patients suffering from melanoma, retrospectively. CGC-PET showed a sensitivity of 76%, and a specificity of 94%. In comparison to conventional diagnostic methods, CGC-PET delineated important additional information in 16%. CGC-PET was superior to morphological diagnostic tools in the differentiation between residual scar tissue and active tumor following immunochemotherapy. Malignant lymphoma: 29 CGC-PET in 29 patients were performed for staging of malignant lymphoma, sensitivity was 86% versus 88% for CT. Overall CGC-PET showed additional information to conventional diagnostic methods, but revealed problems in detecting small infiltrations of organs. In restaging malignant melanoma (26 patients, 33 studies), specificity of CGC-PET was superior to conventional diagnostics (92% versus 35%). (orig.) [de

  5. F-18-FDG-hybrid-camera-PET in patients with postoperative fever

    International Nuclear Information System (INIS)

    Meller, J.; Lehmann, K.; Siefker, U.; Meyer, I.; Altenvoerde, G.; Becker, W.; Sahlmann, C.O.; Schreiber, K.

    2002-01-01

    Aim: Evaluation of F-18-FDG-hybrid-camera-PET imaging in patients with undetermined postoperative fever (POF). Methods: Prospective study of 18 patients (9 women, 9 men; age 23-85 years) suffering from POF with 2-fluoro-2'-deoxyglucose (F-18-FDG) using a dual headed coincidence camera (DHCC). Surgery had been performed 5-94 days prior to our investigation. 13 of the 18 patients received antibiotic therapy during the time of evaluation. Ten (55%) had an infectious and eight (45%) a norr infectious cause of fever. Results: Increased F-18-FDG-uptake outside the surgical wound occurred in 13 regions (infection n = 11, malignancy n = 2). The sensitivity of F-18-FDG-hybrid-camera-PET in imaging infection in areas outside the surgical wound was 86% and the specificity 100%, respectively. Antibiotic therapy did not negatively influence the results of F-18-FDG-scanning. Increased F-18-FDG-uptake within the surgical wound was seen in 8 of 18 patients. The sensitivity of F-18-FDG-hybrid-camera-PET in imaging infection within the surgical wound was 100% and the specificty 56%, respectively. The interval between surgery and F-18-FDG-scanning was significantly shorter in patients with false positive results compared with patients showing true negative results (median 34 vs. 54 days; p = 0,038). Conclusion: In POF-Patients, F-18-FDG transaxial tomography performed with a F-18-FDG-hybrid-camera-PET is sensitive in the diagnosis of inflammation and malignant disease within and outside the surgical wound. Because of the accumulation of the tracer both in granulation tissue and infection, the specificity in detecting the focus of fever within the surgical wound is poor. (orig.) [de

  6. Limits of Tumor Detectability in Nuclear Medicine and PET

    Directory of Open Access Journals (Sweden)

    Yusuf Emre Erdi

    2012-04-01

    Full Text Available Objective: Nuclear medicine is becoming increasingly important in the early detection of malignancy. The advantage of nuclear medicine over other imaging modalities is the high sensitivity of the gamma camera. Nuclear medicine counting equipment has the capability of detecting levels of radioactivity which exceed background levels by as little as 2.4 to 1. This translates to only a few hundred counts per minute on a regular gamma camera or as few as 3 counts per minute when using coincidence detection on a positron emission tomography (PET camera. Material and Methods: We have experimentally measured the limits of detectability using a set of hollow spheres in a Jaszczak phantom at various tumor-to-background ratios. Imaging modalities for this work were (1 planar, (2 SPECT, (3 PET, and (4 planar camera with coincidence detection capability (MCD. Results: When there is no background (infinite contrast activity present, the detectability of tumors is similar for PET and planar imaging. With the presence of the background activity , PET can detect objects in an order of magnitude smaller in size than that can be seen by conventional planar imaging especially in the typical clinical low (3:1 T/B ratios. The detection capability of the MCD camera lies between a conventional nuclear medicine (planar / SPECT scans and the detection capability of a dedicated PET scanner Conclusion: Among nuclear medicine’s armamentarium, PET is the closest modality to CT or MR imaging in terms of limits of detection. Modern clinical PET scanners have a resolution limit of 4 mm, corresponding to the detection of tumors with a volume of 0.2 ml (7 mm diameter in 5:1 T/B ratio. It is also possible to obtain better resolution limits with dedicated brain and animal scanners. The future holds promise in development of new detector materials, improved camera design, and new reconstruction algorithms which will improve sensitivity, resolution, contrast, and thereby further

  7. [F18]-FDG imaging of experimental animal tumours using a hybrid gamma-camera

    International Nuclear Information System (INIS)

    Lausson, S.; Maurel, G.; Kerrou, K.; Montravers, F.; Petegnief, Y.; Talbot, J.N.; Fredelizi, D.

    2001-01-01

    Positron emission tomography (PET) has been widely used in clinical studies. This technology permits detection of compounds labelled with positron emitting radionuclides and in particular, [F18]-fluorodeoxyglucose ([F18]-FDG).[F18]-FDG uptake and accumulation is generally related to malignancy; some recent works have suggested the usefulness of PET camera dedicated to small laboratory animals (micro-PET). Our study dealt with the feasibility of [F18]-FDG imaging of malignant tumours in animal models by means of an hybrid camera dedicated for human scintigraphy. We evaluated the ability of coincidence detection emission tomography (CDET) using this hybrid camera to visualize in vivo subcutaneous tumours grafted to mice or rats. P815 murine mastocytoma grafted in syngeneic DBA/2 mice resulted with foci of very high FDG uptake. Tumours with a diameter of only 3 mm were clearly visualized. Medullary thyroid cancer provoked by rMTC 6/23 and CA77 lines in syngeneic Wag/Rij rat was also detected. The differentiated CA77 tumours exhibited avidity for [F18]-FDG and a tumour, which was just palpable (diameter lower than 2 mm), was identified. In conclusion, CDET-FDG is a non-invasive imaging tool which can be used to follow grafted tumours in the small laboratory animal, even when their size is smaller than 1 cm. It has the potential to evaluate experimental anticancer treatments in small series of animals by individual follow-up. It offers the opportunity to develop experimental PET research within a nuclear medicine or biophysics department, the shift to a dedicated micro-PET device being subsequently necessary. It is indeed compulsory to strictly follow the rules for non contamination and disinfection of the hybrid camera. (authors)

  8. Demonstration of an Axial PET concept for brain and small animal imaging

    CERN Document Server

    Beltrame, P; Clinthorne, N; Meddi, F; Kagan, H; Braem, A; Pauss, F; Djambazov, L; Lustermann, W; Weilhammer, P; Nessi-Tedaldi, F; Dissertori, G; Renker, D; Schneider, T; Schinzel, D; De Leo, R; Bolle, E; Fanti, V; Rafecas, M; Rudge, A; Stapnes, S; Casella, C; Chesi, E; Seguinot, J; Solevi, P; Joram, C; Oliver, J F

    2011-01-01

    Standard Positron Emission Tomography (PET) cameras need to reach a compromise between spatial resolution and sensitivity. To overcome this limitation we developed a novel concept of PET. Our AX-PET demonstrator is made of LYSO crystals aligned along the z coordinate (patient's axis) and WLS strips orthogonally placed with respect to the crystals. This concept offers full 3D localization of the photon interaction inside the camera. Thus the spatial resolution and the sensitivity can be simultaneously improved and the reconstruction of Compton interactions inside the detector is also possible. Moreover, by means of G-APDs for reading out the photons, both from LYSO and WLS, the detector is insensitive to magnetic fields and it is then suitable to be used in a combined PET/MRI apparatus. A complete Monte Carlo simulation and dedicated reconstruction software have been developed. The two final modules, each composed of 48 crystals and 156 WLS strips, have been built and fully characterized in a dedicated test se...

  9. A dedicated tool for PET scanner simulations using FLUKA

    International Nuclear Information System (INIS)

    Ortega, P.G.; Boehlen, T.T.; Cerutti, F.; Chin, M.P.W.; Ferrari, A.; Mancini, C.; Vlachoudis, V.; Mairani, A.; Sala, Paola R.

    2013-06-01

    Positron emission tomography (PET) is a well-established medical imaging technique. It is based on the detection of pairs of annihilation gamma rays from a beta+-emitting radionuclide, usually inoculated in the body via a biologically active molecule. Apart from its wide-spread use for clinical diagnosis, new applications are proposed. This includes notably the usage of PET for treatment monitoring of radiation therapy with protons and ions. PET is currently the only available technique for non-invasive monitoring of ion beam dose delivery, which was tested in several clinical pilot studies. For hadrontherapy, the distribution of positron emitters, produced by the ion beam, can be analyzed to verify the correct treatment delivery. The adaptation of previous PET scanners to new environments and the necessity of more precise diagnostics by better image quality triggered the development of new PET scanner designs. The use of Monte Carlo (MC) codes is essential in the early stages of the scanner design to simulate the transport of particles and nuclear interactions from therapeutic ion beams or radioisotopes and to predict radiation fields in tissues and radiation emerging from the patient. In particular, range verification using PET is based on the comparison of detected and simulated activity distributions. The accuracy of the MC code for the relevant physics processes is obviously essential for such applications. In this work we present new developments of the physics models with importance for PET monitoring and integrated tools for PET scanner simulations for FLUKA, a fully-integrated MC particle-transport code, which is widely used for an extended range of applications (accelerator shielding, detector and target design, calorimetry, activation, dosimetry, medical physics, radiobiology, ...). The developed tools include a PET scanner geometry builder and a dedicated scoring routine for coincident event determination. The geometry builder allows the efficient

  10. Evaluation of pulmonary nodules and lung cancer with one-inch crystal gamma coincidence positron emission tomography/CT versus dedicated positron emission tomography/CT

    International Nuclear Information System (INIS)

    Moodie, K.; Lau, E.; Hicks, R. J.; Cherk, M. H.; Turlakow, A.; Skinner, S.; Kelly, M. J.; Kalff, V.

    2009-01-01

    Full text: Dedicated positron emission tomography (PET)/CT scanners using BGO and related detectors (d-PET) have become standard imaging instruments in many malignancies. Hybrid gamma camera systems using Nal detectors in coincidence mode (g-PET) have been compared to d-PET but reported usefulness has been variable when gamma cameras with half-inch to three-fourth-inch thick crystals have been used without CT. Our aim was to compare g-PET with a 1-in.-thick crystal and inbuilt CT for lesion localization and attenuation correction (g-PET/CT) and d-PET/CT in patients presenting with potential and confirmed lung malignancies. One hour after 18F-fluorodeoxyglucose (FDG), patients underwent BGO d-PET/CT from jaw to proximal thigh. This was followed by one to two bed position g-PET/CT 194 + 27 min after FDG. Each study pair was independently analysed with concurrent CT. d-PET/CT was interpreted by a radiologist experienced in both PET and CT, and g-PET/CT by consensus reading of an experienced PET physician and an experienced CT radiologist, A TNM score was assigned and studies were then unblinded and compared. Fifty-seven patients underwent 58 scan pairs over 2 years. Eighty-nine percent concordance was shown between g-PET/CT and d-PET/CT for the assessment of I intrapulmonary lesions, with 100% concordance for intrapulmonary lesions I >10 mm (36 of 36). Eighty-eight per cent (51 of 58) concordance was shown between g-PET/CTand d-PET/CTforTNM staging. Coincidence imaging usingan optimized dual-head 1-in.-thick crystal gamma camera with inbuilt CT compares reasonably well with dedicated PET/CT for evaluation of indeterminate pulmonary lesions and staging of pulmonary malignancies and may be of some] value when d-PET/CT is not readily available.

  11. A practical block detector for a depth-encoding PET camera

    International Nuclear Information System (INIS)

    Rogers, J.G.; Moisan, C.; Hoskinson, E.M.; Andreaco, M.S.; Williams, C.W.; Nutt, R.

    1996-01-01

    The depth-of-interaction effect in block detectors degrades the image resolution in commercial PET cameras and impedes the natural evolution of smaller, less expensive cameras. A method for correcting the measured position of each detected gamma ray by measuring its depth-of-interaction was tested and found to recover 38% of the lost resolution at 7.5 cm radius in a tabletop, 50-cm-diameter camera. To obtain the desired depth sensitivity, standard commercial detectors were modified by a simple and practical process that is suitable for mass production of the detectors. The impact of the detector modifications on central image resolution and on the ability of the camera to correct for object scatter were also measured

  12. A practical block detector for a depth encoding PET camera

    International Nuclear Information System (INIS)

    Rogers, J.G.; Moisan, C.; Hoskinson, E.M.

    1995-10-01

    The depth-of-interaction effect in block detectors degrades the image resolution in commercial PET cameras and impedes the natural evolution of smaller, less expensive cameras. A method for correcting the measured position of each detected gamma ray by measuring its depth-of-interaction was tested and found to recover 38% of the lost resolution in a table-top 50 cm diameter camera. To obtain the desired depth sensitivity, standard commercial detectors were modified by a simple and practical process, which is suitable for mass production of the detectors. The impact of the detectors modifications on central image resolution and on the ability of the camera to correct for object scatter were also measured. (authors)

  13. Added value of dedicated axillary hybrid 18F-FDG PET/MRI for improved axillary nodal staging in clinically node-positive breast cancer patients. A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Nijnatten, Thiemo J.A. van; Goorts, B. [Maastricht University Medical Center+, Department of Radiology and Nuclear Medicine (Netherlands); Maastricht University Medical Center+, Department of Surgery, Maastricht (Netherlands); Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Voeoe, S.; Wildberger, J.E. [Maastricht University Medical Center+, Department of Radiology and Nuclear Medicine (Netherlands); Boer, M. de [Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Maastricht University Medical Center+, Division of Internal Medicine, Department of Medical Oncology, Maastricht (Netherlands); Kooreman, L.F.S. [Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Maastricht University Medical Center+, Department of Pathology, Maastricht (Netherlands); Heuts, E.M. [Maastricht University Medical Center+, Department of Surgery, Maastricht (Netherlands); Mottaghy, F.M. [Maastricht University Medical Center+, Department of Radiology and Nuclear Medicine (Netherlands); RWTH Aachen University, Department of Nuclear Medicine, University Hospital, Aachen (Germany); Lobbes, M.B.I. [Maastricht University Medical Center+, Department of Radiology and Nuclear Medicine (Netherlands); Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Smidt, M.L. [Maastricht University Medical Center+, Department of Surgery, Maastricht (Netherlands); Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands)

    2018-02-15

    To investigate the feasibility and potential added value of dedicated axillary 18F-FDG hybrid PET/MRI, compared to standard imaging modalities (i.e. ultrasound [US], MRI and PET/CT), for axillary nodal staging in clinically node-positive breast cancer. Twelve patients with clinically node-positive breast cancer underwent axillary US and dedicated axillary hybrid 18F-FDG PET/MRI. Nine of the 12 patients also underwent whole-body PET/CT. Maximum standardized uptake values (SUVmax) were measured for the primary breast tumor and the most FDG-avid axillary lymph node. A positive axillary lymph node on dedicated axillary hybrid PET/MRI was defined as a moderate to very intense FDG-avid lymph node. The diagnostic performance of dedicated axillary hybrid PET/MRI was calculated by comparing quantitative and its qualitative measurements to results of axillary US, MRI and PET/CT. The number of suspicious axillary lymph nodes was subdivided as follows: N0 (0 nodes), N1 (1-3 nodes), N2 (4-9 nodes) and N3 (≥ 10 nodes). According to dedicated axillary hybrid PET/MRI findings, seven patients were diagnosed with N1, four with N2 and one with N3. With regard to mean SUVmax, there was no significant difference in the primary tumor (9.0 [±5.0] vs. 8.6 [±5.7], p = 0.678) or the most FDG-avid axillary lymph node (7.8 [±5.3] vs. 7.7 [±4.3], p = 0.767) between dedicated axillary PET/MRI and PET/CT. Compared to standard imaging modalities, dedicated axillary hybrid PET/MRI resulted in changes in nodal status as follows: 40% compared to US, 75% compared to T2-weighted MRI, 40% compared to contrast-enhanced MRI, and 22% compared to PET/CT. Adding dedicated axillary 18F-FDG hybrid PET/MRI to diagnostic work-up may improve the diagnostic performance of axillary nodal staging in clinically node-positive breast cancer patients. (orig.)

  14. Added value of dedicated axillary hybrid 18F-FDG PET/MRI for improved axillary nodal staging in clinically node-positive breast cancer patients. A feasibility study

    International Nuclear Information System (INIS)

    Nijnatten, Thiemo J.A. van; Goorts, B.; Voeoe, S.; Wildberger, J.E.; Boer, M. de; Kooreman, L.F.S.; Heuts, E.M.; Mottaghy, F.M.; Lobbes, M.B.I.; Smidt, M.L.

    2018-01-01

    To investigate the feasibility and potential added value of dedicated axillary 18F-FDG hybrid PET/MRI, compared to standard imaging modalities (i.e. ultrasound [US], MRI and PET/CT), for axillary nodal staging in clinically node-positive breast cancer. Twelve patients with clinically node-positive breast cancer underwent axillary US and dedicated axillary hybrid 18F-FDG PET/MRI. Nine of the 12 patients also underwent whole-body PET/CT. Maximum standardized uptake values (SUVmax) were measured for the primary breast tumor and the most FDG-avid axillary lymph node. A positive axillary lymph node on dedicated axillary hybrid PET/MRI was defined as a moderate to very intense FDG-avid lymph node. The diagnostic performance of dedicated axillary hybrid PET/MRI was calculated by comparing quantitative and its qualitative measurements to results of axillary US, MRI and PET/CT. The number of suspicious axillary lymph nodes was subdivided as follows: N0 (0 nodes), N1 (1-3 nodes), N2 (4-9 nodes) and N3 (≥ 10 nodes). According to dedicated axillary hybrid PET/MRI findings, seven patients were diagnosed with N1, four with N2 and one with N3. With regard to mean SUVmax, there was no significant difference in the primary tumor (9.0 [±5.0] vs. 8.6 [±5.7], p = 0.678) or the most FDG-avid axillary lymph node (7.8 [±5.3] vs. 7.7 [±4.3], p = 0.767) between dedicated axillary PET/MRI and PET/CT. Compared to standard imaging modalities, dedicated axillary hybrid PET/MRI resulted in changes in nodal status as follows: 40% compared to US, 75% compared to T2-weighted MRI, 40% compared to contrast-enhanced MRI, and 22% compared to PET/CT. Adding dedicated axillary 18F-FDG hybrid PET/MRI to diagnostic work-up may improve the diagnostic performance of axillary nodal staging in clinically node-positive breast cancer patients. (orig.)

  15. Clear-PEM: A dedicated PET camera for improved breast cancer detection

    International Nuclear Information System (INIS)

    Abreu, M. C.; Almeida, P.; Balau, F.; Ferreira, N. C.; Fetal, S.; Fraga, F.; Martins, M.; Matela, N.; Moura, R.; Ortigao, C.; Peralta, L.; Rato, P.; Ribeiro, R.; Rodrigues, P.; Santos, A. I.; Trindade, A.; Varela, J.

    2005-01-01

    Positron emission mammography (PEM) can offer a non-invasive method for the diagnosis of breast cancer. Metabolic images from PEM using 18 F-fluoro-deoxy-glucose, contain unique information not available from conventional morphologic imaging techniques like X-ray radiography. In this work, the concept of Clear-PEM, the system presently developed in the frame of the Crystal Clear Collaboration at CERN, is described. Clear-PEM will be a dedicated scanner, offering better perspectives in terms of position resolution and detection sensitivity. (authors)

  16. A novel PET camera calibration method

    International Nuclear Information System (INIS)

    Yerian, K.; Hartz, R.K.; Gaeta, J.M.; Marani, S.; Wong, W.H.; Bristow, D.; Mullani, N.A.

    1985-01-01

    Reconstructed time-of-flight PET images must be corrected for differences in the sensitivity of detector pairs, variations in the TOF gain between groups of detector pairs, and for shifts in the detector-pair timing windows. These calibration values are measured for each detector-pair coincidence line using a positron emitting ring source. The quality of the measured value for a detector pair depends on its statistics. To improve statistics, algorithms are developed which derive individual detector calibration values for efficiency, TOF offsets, and TOF fwhm from the raw detector-pair measurements. For the author's current TOFPET system there are 162,000 detector pairs which are reduced to 720 individual detector values. The data for individual detectors are subsequently recombined, improving the statistical quality of the resultant detector-pair values. In addition, storage requirements are significantly reduced by saving the individual detector values. These parameters are automatically evaluated on a routine basis and problem detectors reported for adjustment or replacement. Decomposing the detector-pair measurements into individual detector values significantly improves the calibration values used to correct camera artifacts in PET imaging

  17. Time of flight measurements based on FPGA using a breast dedicated PET

    International Nuclear Information System (INIS)

    Aguilar, A; García-Olcina, R; Martos, J; Soret, J; Torres, J; Benlloch, J M; González, A J; Sánchez, F

    2014-01-01

    In this work the implementation of a Time-to-Digital Converter (TDC) using a Nutt delay line FPGA-based and applied on a Positron Emission Tomography (PET) device is going to be presented in order to check the system's suitability for Time of Flight (TOF) measurements. In recent years, FPGAs have shown great advantages for precise time measurements in PET. The architecture employed for these measurements is described in detail. The system developed was tested on a dedicated breast PET prototype, composed of LYSO crystals and Positive Sensitive Photomultipliers (PSPMTs). Two distinct experiments were carried out for this purpose. In the first test, system linearity was evaluated in order to calibrate the time measurements, providing a linearity error of less than 2% and an average time resolution of 1.4 ns FWHM. The second set of measurements tested system resolution, resulting in a FWHM as good as 1.35 ns. The results suggest that the coincidence window for the current PET can be reduced in order to minimize the random events and thus, achieve better image quality

  18. Feasibility of a novel design of high resolution parallax-free Compton enhanced PET scanner dedicated to brain research

    CERN Document Server

    Braem, André; Chesi, Enrico Guido; Correia, J G; Garibaldi, F; Joram, C; Mathot, S; Nappi, E; Ribeiro da Silva, M; Schoenahl, F; Séguinot, Jacques; Weilhammer, P; Zaidi, H

    2004-01-01

    A novel concept for a positron emission tomography (PET) camera module is proposed, which provides full 3D reconstruction with high resolution over the total detector volume, free of parallax errors. The key components are a matrix of long scintillator crystals and hybrid photon detectors (HPDs) with matched segmentation and integrated readout electronics. The HPDs read out the two ends of the scintillator package. Both excellent spatial (x, y, z) and energy resolution are obtained. The concept allows enhancing the detection efficiency by reconstructing a significant fraction of events which underwent Compton scattering in the crystals. The proof of concept will first be demonstrated with yttrium orthoaluminate perovskite (YAP):Ce crystals, but the final design will rely on other scintillators more adequate for PET applications (e.g. LSO:Ce or LaBr /sub 3/:Ce). A promising application of the proposed camera module, which is currently under development, is a high resolution 3D brain PET camera with an axial fi...

  19. Clinical evaluation of 2D versus 3D whole-body PET image quality using a dedicated BGO PET scanner

    International Nuclear Information System (INIS)

    Visvikis, D.; Griffiths, D.; Costa, D.C.; Bomanji, J.; Ell, P.J.

    2005-01-01

    Three-dimensional positron emission tomography (3D PET) results in higher system sensitivity, with an associated increase in the detection of scatter and random coincidences. The objective of this work was to compare, from a clinical perspective, 3D and two-dimensional (2D) acquisitions in terms of whole-body (WB) PET image quality with a dedicated BGO PET system. 2D and 3D WB emission acquisitions were carried out in 70 patients. Variable acquisition parameters in terms of time of emission acquisition per axial field of view (aFOV) and slice overlap between sequential aFOVs were used during the 3D acquisitions. 3D and 2D images were reconstructed using FORE+WLS and OSEM respectively. Scatter correction was performed by convolution subtraction and a model-based scatter correction in 2D and 3D respectively. All WB images were attenuation corrected using segmented transmission scans. Images were blindly assessed by three observers for the presence of artefacts, confidence in lesion detection and overall image quality using a scoring system. Statistically significant differences between 2D and 3D image quality were only obtained for 3D emission acquisitions of 3 min. No statistically significant differences were observed for image artefacts or lesion detectability scores. Image quality correlated significantly with patient weight for both modes of operation. Finally, no differences were seen in image artefact scores for the different axial slice overlaps considered, suggesting the use of five slice overlaps in 3D WB acquisitions. 3D WB imaging using a dedicated BGO-based PET scanner offers similar image quality to that obtained in 2D considering similar overall times of acquisitions. (orig.)

  20. Experience with dedicated ultra fast solid state cardiac gamma camera: technologist perspective

    International Nuclear Information System (INIS)

    Parab, Anil; Gaikar, Anil; Patil, Kashinath; Lele, V.

    2010-01-01

    Full text: To describe technologist perspective of working with ultra fast solid state gamma camera and comparison with conventional dual head gamma camera. Material and Methods: 900 Myocardial Perfusion scan were carried out on dedicated solid state detector cardiac camera between 1st February 2010 till 29th August 2010. 27 studies were done back to back on a conventional dual head gamma camera. In 2 cases dual head isotope imaging was done (Thallium+ 99m Tc-tetrofosmin). Rest stress protocol was used in 600 patients and stress - rest protocol was used in 300. 1:3 ratio of injected activity was maintained for both protocols (5 mCi for 1st study and 15 mCi for second study). For Rest - Stress protocol, 5 mCi of 99m Tc - Tetrofosmin was injected at rest, 40 minutes later, 5 min image was acquired on the solid state detector. Patient was then stressed. 15 mCi 99m Tc - Tetrofosmin was injected at peak stress. Images were acquired 20 minutes later for 3 minutes (total duration of study 90-100 min). For stress rest protocol, 5 mCi 99m Tc - Tetrofosmin was injected at peak stress. 5 mCi images were acquired 20 minutes later. Rest injection of 15 mCi was given 1 hour post stress injection. Rest images were acquired 40 minutes after rest injection (total duration of study 110-120 min). Results: We observed even with lesser amount activity and acquisition time of 5 min/cardiac scan it showed high sensitivity count rate over 2.2-4.7 kcps (10 times more counts than standard gamma camera). System gives better energy resolution < 7%. Better image contrast. Dual isotope imaging can be possible. Spatial resolution 4.3-4.9 mm. Excellent quality images were obtained using low activities (5 mCi/15 mCi) using 1/3rd the acquisition time compared to conventional dual head gamma camera Even in obese patients 7 mCi/21 mCi activity yielded excellent images at 1/3 rd acquisition time Quick acquisition resulted in greater patient comfort and no motion artifact also due to non rotation of

  1. AX-PET: A novel PET concept with G-APD readout

    CERN Document Server

    Heller, M; Casella, C; Chesi, E; De Leo, R; Dissertori, G; Fanti, V; Gillam, J E; Joram, C; Lustermann, W; Nappi, E; Oliver, J F; Pauss, F; Rafecas, M; Rudge, A; Ruotsalainen, U; Schinzel, D; Schneider, T; Seguinot, J; Solevi, P; Stapnes, S; Tuna, U; Weilhammer, P

    2012-01-01

    The AX-PET collaboration has developed a novel concept for high resolution PET imaging to overcome some of the performance limitations of classical PET cameras, in particular the compromise between spatial resolution and sensitivity introduced by the parallax error. The detector consists of an arrangement of long LYSO scintillating crystals axially oriented around the field of view together with arrays of wave length shifter strips orthogonal to the crystals. This matrix allows a precise 3D measurement of the photon interaction point. This is valid both for photoelectric absorption at 511 key and for Compton scattering down to deposited energies of about 100 keV. Crystals and WLS strips are individually read out using Geiger-mode Avalanche Photo Diodes (G-APDs). The sensitivity of such a detector can be adjusted by changing the number of layers and the resolution is defined by the crystal and strip dimensions. Two AX-PET modules were built and fully characterized in dedicated test set-ups at CERN, with point-...

  2. 18F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters.

    Science.gov (United States)

    Mhlanga, Joyce C; Carrino, John A; Lodge, Martin; Wang, Hao; Wahl, Richard L

    2014-12-01

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with (18)F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological (18)F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p = 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted.

  3. The findings of F-18 FDG camera-based coincidence PET in acute leukemia

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, S. N.; Joh, C. W.; Lee, M. H. [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2002-07-01

    We evaluated the usefulness of F-18 FDG coincidence PET (CoDe-PET) using a dual-head gamma camera in the assessment of patients with acute leukemia. F-18 FDG CoDE-PET studies were performed in 5 patients with acute leukemia (6 ALL and 2 AML) before or after treatment. CoDe-PET was performed utilizing a dual-head gamma camera equipped with 5/8 inch NaI(Tl) crystal. Image acquisition began 60 minutes after the injection of F-18 FDG in the fasting state. A whole trunk from cervical to inguinal regions or selected region were scanned. No attenuation correction was made and image reconstruction was done using filtered back-projection. CoDe-PET studies were evaluated visually. F-18 FDG image performed in 5 patients with ALL before therapy depicted multiple lymph node involvement and diffuse increased uptake involving axial skeleton, pelvis and femurs. F-18 FDG image done in 2 AML after chemotherapy showed only diffuse increased uptake in sternum, ribs, spine, pelvis and proximal femur and these may be due to G-CSF stimulation effect in view of drug history. But bone marrow histology showed scattered blast cell suggesting incomplete remission in one and completer remission in another. F-18 image done in 1 ALL after therapy showed no abnormal uptake. CoDe-PET with F-18 FDG in acute lymphoblastic lymphoma showed multiple lymphnode and bone marrow involvement in whole body. Therefore we conclude that CoDe-PET with F-18 FDG usefulness for evaluation of extent in acute lymphoblastic leukemia. But there was a limitation to assess therapy effectiveness during therapy due to reactive bone marrow.

  4. Design study of a high-resolution breast-dedicated PET system built from cadmium zinc telluride detectors

    International Nuclear Information System (INIS)

    Peng Hao; Levin, Craig S

    2010-01-01

    We studied the performance of a dual-panel positron emission tomography (PET) camera dedicated to breast cancer imaging using Monte Carlo simulation. The proposed system consists of two 4 cm thick 12 x 15 cm 2 area cadmium zinc telluride (CZT) panels with adjustable separation, which can be put in close proximity to the breast and/or axillary nodes. Unique characteristics distinguishing the proposed system from previous efforts in breast-dedicated PET instrumentation are the deployment of CZT detectors with superior spatial and energy resolution, using a cross-strip electrode readout scheme to enable 3D positioning of individual photon interaction coordinates in the CZT, which includes directly measured photon depth-of-interaction (DOI), and arranging the detector slabs edge-on with respect to incoming 511 keV photons for high photon sensitivity. The simulation results show that the proposed CZT dual-panel PET system is able to achieve superior performance in terms of photon sensitivity, noise equivalent count rate, spatial resolution and lesion visualization. The proposed system is expected to achieve ∼32% photon sensitivity for a point source at the center and a 4 cm panel separation. For a simplified breast phantom adjacent to heart and torso compartments, the peak noise equivalent count (NEC) rate is predicted to be ∼94.2 kcts s -1 (breast volume: 720 cm 3 and activity concentration: 3.7 kBq cm -3 ) for a ∼10% energy window around 511 keV and ∼8 ns coincidence time window. The system achieves 1 mm intrinsic spatial resolution anywhere between the two panels with a 4 cm panel separation if the detectors have DOI resolution less than 2 mm. For a 3 mm DOI resolution, the system exhibits excellent sphere resolution uniformity (σ rms /mean) ≤ 10%) across a 4 cm width FOV. Simulation results indicate that the system exhibits superior hot sphere visualization and is expected to visualize 2 mm diameter spheres with a 5:1 activity concentration ratio within

  5. Performance characteristics of a small animal PET camera for molecular imaging

    International Nuclear Information System (INIS)

    Hastings, D.L.; Reader, A.J.; Julyan, P.J.; Zweit, J.; Jeavons, A.P.; Jones, T.

    2007-01-01

    The performance of a novel type of animal PET camera, the quad High-Density Avalanche Chamber (HIDAC) was assessed for a non-rotating 16-module system. Spatial resolution was 1.0 mm, and invariant within a standard deviation ≤5%. Absolute sensitivity was 0.95%, and the scatter-background corrected sensitivity was 0.75%. The count rate capability was linear at typical activities used in animal imaging, with a 20% loss at 11.5 MBq. The camera demonstrates small regions of radiotracer uptake with excellent detail in the mouse

  6. PET with coincidence gamma cameras - clinical benefit from the radiooncologists' point of view

    International Nuclear Information System (INIS)

    Richter, E.; Feyerabend, T.; Stallmann, C.; Lauer, I.; Baehre, M.

    2001-01-01

    Positron emission tomography with FDG (FDG-PET) is a new technique, which displays the cellular metabolic activity. Since tumors exhibit an increased metabolic activity when compared to normal tissue, this imaging modality has a particularly high importance. FDG-PET is not only useful for localizing and staging of malignant tumors, but also to evaluate therapy response. In this context, PET is superior to morphologically orientated modalities, because therapeutically induced changes in glucose metabolism precede morphologic alterations. Numerous studies indicate, that PET will play an important role in radiooncology concerning therapy planning and monitoring the effects of therapy during and after treatment. Further clinical studies are necessary to evaluate the information provided by FDG-PET more precisely. Coincidence gamma cameras with adequate imaging characteristics will gain enhanced importance to meet these increasing demands. (orig.) [de

  7. New cardiac cameras: single-photon emission CT and PET.

    Science.gov (United States)

    Slomka, Piotr J; Berman, Daniel S; Germano, Guido

    2014-07-01

    Nuclear cardiology instrumentation has evolved significantly in the recent years. Concerns about radiation dose and long acquisition times have propelled developments of dedicated high-efficiency cardiac SPECT scanners. Novel collimator designs, such as multipinhole or locally focusing collimators arranged in geometries that are optimized for cardiac imaging, have been implemented to enhance photon-detection sensitivity. Some of these new SPECT scanners use solid-state photon detectors instead of photomultipliers to improve image quality and to reduce the scanner footprint. These new SPECT devices allow dramatic up to 7-fold reduction in acquisition times or similar reduction in radiation dose. In addition, new hardware for photon attenuation correction allowing ultralow radiation doses has been offered by some vendors. To mitigate photon attenuation artifacts for the new SPECT scanners not equipped with attenuation correction hardware, 2-position (upright-supine or prone-supine) imaging has been proposed. PET hardware developments have been primarily driven by the requirements of oncologic imaging, but cardiac imaging can benefit from improved PET image quality and improved sensitivity of 3D systems. The time-of-flight reconstruction combined with resolution recovery techniques is now implemented by all major PET vendors. These new methods improve image contrast and image resolution and reduce image noise. High-sensitivity 3D PET without interplane septa allows reduced radiation dose for cardiac perfusion imaging. Simultaneous PET/MR hybrid system has been developed. Solid-state PET detectors with avalanche photodiodes or digital silicon photomultipliers have been introduced, and they offer improved imaging characteristics and reduced sensitivity to electromagnetic MR fields. Higher maximum count rate of the new PET detectors allows routine first-pass Rb-82 imaging, with 3D PET acquisition enabling clinical utilization of dynamic imaging with myocardial flow

  8. Evaluation of 3D reconstruction algorithms for a small animal PET camera

    International Nuclear Information System (INIS)

    Johnson, C.A.; Gandler, W.R.; Seidel, J.

    1996-01-01

    The use of paired, opposing position-sensitive phototube scintillation cameras (SCs) operating in coincidence for small animal imaging with positron emitters is currently under study. Because of the low sensitivity of the system even in 3D mode and the need to produce images with high resolution, it was postulated that a 3D expectation maximization (EM) reconstruction algorithm might be well suited for this application. We investigated four reconstruction algorithms for the 3D SC PET camera: 2D filtered back-projection (FBP), 2D ordered subset EM (OSEM), 3D reprojection (3DRP), and 3D OSEM. Noise was assessed for all slices by the coefficient of variation in a simulated uniform cylinder. Resolution was assessed from a simulation of 15 point sources in the warm background of the uniform cylinder. At comparable noise levels, the resolution achieved with OSEM (0.9-mm to 1.2-mm) is significantly better than that obtained with FBP or 3DRP (1.5-mm to 2.0-mm.) Images of a rat skull labeled with 18 F-fluoride suggest that 3D OSEM can improve image quality of a small animal PET camera

  9. Septa design for a prostate specific PET camera

    International Nuclear Information System (INIS)

    Qi, Jinyi; Huber, Jennifer S.; Huesman, Ronald H.; Moses, William W.; Derenzo, Stephen E.; Budinger, Thomas F.

    2003-01-01

    The recent development of new prostate tracers has motivated us to build a low cost PET camera optimized to image the prostate. Coincidence imaging of positron emitters is achieved using a pair of external curved detector banks. The bottom bank is fixed below the patient bed, and the top bank moves upward for patient access and downward for maximum sensitivity. In this paper, we study the design of septa for the prostate camera using Monte Carlo simulations. The system performance is measured by the detectability of a prostate lesion. We have studied 17 septa configurations. The results show that the design of septa has a large impact on the lesion detection at a given activity concentration. Significant differences are also observed between the lesion detectability and the conventional noise equivalent count (NEC) performance, indicating that the NEC is not appropriate for the detection task

  10. 18F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters

    International Nuclear Information System (INIS)

    Mhlanga, Joyce C.; Lodge, Martin; Carrino, John A.; Wang, Hao; Wahl, Richard L.

    2014-01-01

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with 18 F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological 18 F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p= 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted. (orig.)

  11. D-SPECT, a semiconductor camera: Technical aspects and clinical applications

    International Nuclear Information System (INIS)

    Merlin, C.; Bertrand, S.; Kelly, A.; Veyre, A.; Mestas, D.; Cachin, F.; Motreff, P.; Levesque, S.; Cachin, F.; Askienazy, S.

    2010-01-01

    Clinical practice in nuclear medicine has largely changed in the last decade, particularly with the arrival of PET/CT and SPECT/CT. New semiconductor cameras could represent the next evolution in our nuclear medicine practice. Due to the resolution and sensitivity improvement, this technology authorizes fast speed acquisitions, high contrast and resolution images performed with low activity injection. The dedicated cardiology D-SPECT camera (Spectrum Dynamics, Israel) is based on semiconductor technology and provides an original system for collimation and images reconstruction. We describe here our clinical experience in using the D-SPECT with a preliminary study comparing D-D.P.E.C.T. and conventional gamma camera. (authors)

  12. Incremental clinical value of a dedicated RT planning FDG PET-CT over staging PET-CT in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Lin, P.; Som, S.; Vinod, S.; Lin, M.; Shon, I. H.

    2009-01-01

    Full text:Objectives: To evaluate whether FDG-PET performed for radiotherapy planning can detect disease progression, compared with staging PET. Methods: Thirteen patients underwent a planning PET-CT for curative RT ( R T-PET ) within eight weeks of a staging PET-CT for newly diagnosed NSCLC between 10/2007 and 1/2009. All studies were acquired on a Philips GXL PET-CT using the same protocols, except RT-PET is acquired on a RT flat bed. The images were interpreted by consensus readings of two physicians: location/number, visual grading (0-4:3> liver, 4>brain), max transverse diameter ( M ax D ) (tumour margin is delineated by a SUV threshold of 2.5) and max SUV of each lesion. Progressive disease (PD) is defined as >10% increase in max D. Results: RT-PET detected PD (primary or nodal) or new metastases in 8 pts (61%) (mean interval:30.2±14 days, range:7-54 days). For primary tumour, RT-PET detected PD in 5 pts (range: 12-32% increase in max D and 12-39% increase in SUV) and RT-CT detected PD in 3 pts (11-21% increase in max D, paired t test: p = 0.19). Stage-PET detected 28 mediastinal/hilar nodal sites. RT-PET detected PD in 11 of these lesions in 4 pts (31%) and CT detected similar progression in 8 lesions in 2 pts. RT-PET detected 10 new lesions in 3 pts (23%) resulting in upstaging to N3 in 2 pts (supraclavicular and hilar nodes) and M1 in 1 pt (bone). Conclusion: A dedicated RT PET-CT has the potential to detect disease progression and impact on RT planning in a large number of patients.

  13. Dedicated mobile high resolution prostate PET imager with an insertable transrectal probe

    Science.gov (United States)

    Majewski, Stanislaw; Proffitt, James

    2010-12-28

    A dedicated mobile PET imaging system to image the prostate and surrounding organs. The imaging system includes an outside high resolution PET imager placed close to the patient's torso and an insertable and compact transrectal probe that is placed in close proximity to the prostate and operates in conjunction with the outside imager. The two detector systems are spatially co-registered to each other. The outside imager is mounted on an open rotating gantry to provide torso-wide 3D images of the prostate and surrounding tissue and organs. The insertable probe provides closer imaging, high sensitivity, and very high resolution predominately 2D view of the prostate and immediate surroundings. The probe is operated in conjunction with the outside imager and a fast data acquisition system to provide very high resolution reconstruction of the prostate and surrounding tissue and organs.

  14. {sup 18}F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters

    Energy Technology Data Exchange (ETDEWEB)

    Mhlanga, Joyce C.; Lodge, Martin [Johns Hopkins University School of Medicine, Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Carrino, John A. [Johns Hopkins University School of Medicine, Division of Musculoskeletal Radiology, The Russell H. Morgan Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Wang, Hao [Johns Hopkins University School of Medicine, Department of Oncology Biostatistics Division, Baltimore, MD (United States); Wahl, Richard L. [Johns Hopkins University School of Medicine, Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Johns Hopkins University Hospitals, Division of Nuclear Medicine, Baltimore, MD (United States)

    2014-12-15

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with {sup 18}F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological {sup 18}F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p= 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted. (orig.)

  15. Study and development of a PET device dedicated to cancer monitoring

    International Nuclear Information System (INIS)

    Vandenbussche, Vincent

    2014-01-01

    Medical imaging first began at the end of the 19. century with the discover of X-rays by Roentgen. Then, numerous imaging modalities have been developed and are used now for a wide range of cases. Positron Emission Tomography (PET) has a high sensitivity, is functional and quantitative, thus being of high interest in cancer monitoring. Nevertheless, PET is not as much spread in hospitals as magnetic resonance imaging and scanner. In this context, this work aims to prove the feasibility of PET dedicated for cancer monitoring. Thanks to instrumental developments such as light sharing in scintillating crystals, use of Silicon Photomultipliers, and an original geometry, cost is expected to be reduced while having same performances as commercial devices. An extensive study of light sharing within scintillating barrels has been made, through many parameters (crystal length, coating, data analysis...). An intrinsic spatial resolution of 4 mm has been measured over a 75 mm long crystal of LYSO, coated with teflon. From such a configuration, a first image has been reconstructed using two modules in coincidence. A spatial resolution of 5 mm has been measured in the image. Finally, Monte Carlo simulations has been made with experimental data as input, in order to measure the performances of the final PET device. Thanks to NEMA standard protocol, performances has been measured and compared to other systems. A spatial resolution of 4 mm has been reached, for a sensitivity of 2.5 cps/kBq. Quantification problem has been assessed, providing results similar to existing devices. (author) [fr

  16. Comparison of benzodiazepine receptor SPECT and 18F-FDG PET using a coincidence detection camera in patients with temporal lobe epilepsy: preliminary results

    International Nuclear Information System (INIS)

    Wissmeyer, M.; Geiger, L.; Luescher, D.; Krause, T.; Loevblad, K.; Donati, F.; Wielepp, J.P.

    2002-01-01

    significant. 18 F-FDG PET using a coincidence detection camera system shows slightly but not statistically significant higher subjective values of asymmetry in patients with medically intractable TLE than BDR SPECT. Thus, in institutions without a dedicated PET scanner, both methods provide useful additional functional information in the detection of epileptogenic foci, especially when combined with an additional interictal CBF SPECT. (author)

  17. A method for correcting the depth-of-interaction blurring in PET cameras

    International Nuclear Information System (INIS)

    Rogers, J.G.

    1993-11-01

    A method is presented for the purpose of correcting PET images for the blurring caused by variations in the depth-of-interaction in position-sensitive gamma ray detectors. In the case of a fine-cut 50x50x30 mm BGO block detector, the method is shown to improve the detector resolution by about 25%, measured in the geometry corresponding to detection at the edge of the field-of-view. Strengths and weaknesses of the method are discussed and its potential usefulness for improving the images of future PET cameras is assessed. (author). 8 refs., 3 figs

  18. Quantitatively accurate activity measurements with a dedicated cardiac SPECT camera: Physical phantom experiments

    Energy Technology Data Exchange (ETDEWEB)

    Pourmoghaddas, Amir, E-mail: apour@ottawaheart.ca; Wells, R. Glenn [Physics Department, Carleton University, Ottawa, Ontario K1S 5B6, Canada and Cardiology, The University of Ottawa Heart Institute, Ottawa, Ontario K1Y4W7 (Canada)

    2016-01-15

    Purpose: Recently, there has been increased interest in dedicated cardiac single photon emission computed tomography (SPECT) scanners with pinhole collimation and improved detector technology due to their improved count sensitivity and resolution over traditional parallel-hole cameras. With traditional cameras, energy-based approaches are often used in the clinic for scatter compensation because they are fast and easily implemented. Some of the cardiac cameras use cadmium-zinc-telluride (CZT) detectors which can complicate the use of energy-based scatter correction (SC) due to the low-energy tail—an increased number of unscattered photons detected with reduced energy. Modified energy-based scatter correction methods can be implemented, but their level of accuracy is unclear. In this study, the authors validated by physical phantom experiments the quantitative accuracy and reproducibility of easily implemented correction techniques applied to {sup 99m}Tc myocardial imaging with a CZT-detector-based gamma camera with multiple heads, each with a single-pinhole collimator. Methods: Activity in the cardiac compartment of an Anthropomorphic Torso phantom (Data Spectrum Corporation) was measured through 15 {sup 99m}Tc-SPECT acquisitions. The ratio of activity concentrations in organ compartments resembled a clinical {sup 99m}Tc-sestamibi scan and was kept consistent across all experiments (1.2:1 heart to liver and 1.5:1 heart to lung). Two background activity levels were considered: no activity (cold) and an activity concentration 1/10th of the heart (hot). A plastic “lesion” was placed inside of the septal wall of the myocardial insert to simulate the presence of a region without tracer uptake and contrast in this lesion was calculated for all images. The true net activity in each compartment was measured with a dose calibrator (CRC-25R, Capintec, Inc.). A 10 min SPECT image was acquired using a dedicated cardiac camera with CZT detectors (Discovery NM530c, GE

  19. Initial clinical experience with dedicated ultra fast solid state cardiac gamma camera

    International Nuclear Information System (INIS)

    Aland, Nusrat; Lele, V.

    2010-01-01

    Full text: To analyze the imaging and diagnostic performance of new dedicated ultra fast solid state detector gamma camera and compare it with standard dual detector gamma camera in myocardial perfusion imaging. Material and Methods: In total 900 patients underwent myocardial perfusion imaging between 1st February 2010 and 29th August 2010 either stress/rest or rest/stress protocol. There was no age or gender bias (there were 630 males and 270 females). 5 and 15 mCi of 99m Tc - Tetrofosmin/MIBI was injected for 1st and 2nd part of the study respectively. Waiting period after injection was 20 min for regular stress and 40 min for pharmacological stress and 40 min after rest injection. Acquisition was performed on solid state detector gamma camera for a duration of 5 min and 3 min for 1st and 2nd part respectively. Interpretation of myocardial perfusion was done and QGS/QPS protocol was used for EF analysis. Out of these, 20 random patients underwent back to back myocardial perfusion SPECT imaging on standard dual detector gamma camera on same day. There was no age or gender bias (there were 9 males, 11 females). Acquisition time was 20 min for each part of the study. Interpretation was done using Autocard and EF analyses with 4 DM SPECT. Images obtained were then compared with those of solid state detector gamma camera. Result: Good quality and high count myocardial perfusion images were obtained with lesser amount of tracer activity on solid state detector gamma camera. Obese patients also showed good quality images with less tracer activity. As compared to conventional dual detector gamma camera images were brighter and showed better contrast with solid state gamma camera. Right ventricular imaging was better seen. Analyses of diastolic dysfunction was possible with 16 frame gated studies with solid state gamma camera. Shorter acquisition time with comfortable position reduced possibility of patient motion. All cardiac views were obtained with no movement of the

  20. Design studies of a depth encoding large aperture PET camera

    International Nuclear Information System (INIS)

    Moisan, C.; Rogers, J.G.; Buckley, K.R.; Ruth, T.J.; Stazyk, M.W.; Tsang, G.

    1994-10-01

    The feasibility of a wholebody PET tomograph with the capacity to correct for the parallax error induced by the Depth-Of-Interaction of γ-rays is assessed through simulation. The experimental energy, depth, and transverse position resolutions of BGO block detector candidates are the main inputs to a simulation that predicts the point source resolution of the Depth Encoding Large Aperture Camera (DELAC). The results indicate that a measured depth resolution of 7 mm (FWHM) is sufficient to correct a substantial part of the parallax error for a point source at the edge of the Field-Of-View. A search for the block specifications and camera ring radius that would optimize the spatial resolution and its uniformity across the Field-Of-View is also presented. (author). 10 refs., 1 tab., 5 figs

  1. Gamma camera based Positron Emission Tomography: a study of the viability on quantification; Tomografia por emissao de positrons com sistemas PET/SPECT: um estudo da viabilidade de quantifizacao

    Energy Technology Data Exchange (ETDEWEB)

    Pozzo, Lorena

    2005-07-01

    Positron Emission Tomography (PET) is a Nuclear Medicine imaging modality for diagnostic purposes. Pharmaceuticals labeled with positron emitters are used and images which represent the in vivo biochemical process within tissues can be obtained. The positron/electron annihilation photons are detected in coincidence and this information is used for object reconstruction. Presently, there are two types of systems available for this imaging modality: the dedicated systems and those based on gamma camera technology. In this work, we utilized PET/SPECT systems, which also allows for the traditional Nuclear Medicine studies based on single photon emitters. There are inherent difficulties which affect quantification of activity and other indices. They are related to the Poisson nature of radioactivity, to radiation interactions with patient body and detector, noise due to statistical nature of these interactions and to all the detection processes, as well as the patient acquisition protocols. Corrections are described in the literature and not all of them are implemented by the manufacturers: scatter, attenuation, random, decay, dead time, spatial resolution, and others related to the properties of each equipment. The goal of this work was to assess these methods adopted by two manufacturers, as well as the influence of some technical characteristics of PET/SPECT systems on the estimation of SUV. Data from a set of phantoms were collected in 3D mode by one camera and 2D, by the other. We concluded that quantification is viable in PET/SPECT systems, including the estimation of SUVs. This is only possible if, apart from the above mentioned corrections, the camera is well tuned and coefficients for sensitivity normalization and partial volume corrections are applied. We also verified that the shapes of the sources used for obtaining these factors play a role on the final results and should be delt with carefully in clinical quantification. Finally, the choice of the region

  2. Development of a liquid xenon Compton telescope dedicated to functional medical imaging

    International Nuclear Information System (INIS)

    Grignon, C.

    2007-12-01

    Functional imaging is a technique used to locate in three dimensions the position of a radiotracer previously injected in a patient. The two main modalities used for a clinical application to detect tumors, the SPECT and the PET, use solid scintillators as a detection medium. The objective of this thesis was to investigate the possibility of using liquid xenon in order to benefit from the intrinsic properties of this medium in functional imaging. The feasibility study of such a device has been performed by taking into account the technical difficulties specific to the liquid xenon. First of all, simulations of a liquid xenon PET has been performed using Monte-Carlo methods. The results obtained with a large liquid xenon volume are promising : we can expect a reduction of the injected activity of radiotracer, an improvement of the spatial resolution of the image and a parallax free camera. The second part of the thesis was focused on the development of a new concept of medical imaging, the three gamma imaging, based on the use of a new emitter: the 44 scandium. Associated to a classical PET camera, the Compton telescope is used to infer the incoming direction of the third gamma ray by triangulation. Therefore, it is possible to reconstruct the position of each emitter in three dimensions. This work convinced the scientific community to support the construction and characterization of a liquid xenon Compton telescope. The first camera dedicated to small animal imaging should then be operational in 2009. (author)

  3. A basic study on lesion detectability for hot spot imaging of positron emitters with dedicated PET and positron coincidence gamma camera

    International Nuclear Information System (INIS)

    Zhang, Hong; Inoue, Tomio; Tian, Mei; Alyafei, Saleh; Oriuchi, Noboru; Khan, Nasim; Endo, Keigo; Li Sijin

    2001-01-01

    The aim of this study was to explore the correlations of detectability and the semi-quantification for hot spot imaging with positron emitters in positron emission tomography (PET) and with a positron coincidence detection system (PCD). Phantom study results for the measurement of the lesion-to-background (L/B) ratio ranged from 2.0 to 30.3, and detectability for hot spot lesion of PET and PCD were performed to correspond to clinical conditions. The detectability and semi-quantitative evaluation of hot spots from 4.4 mm to 36.9 mm in diameter were performed from the PET and PCD images. There were strong correlations between the L/B ratios derived from PET and PCD hot spot images and actual L/B ratios; but the L/B ratio derived from PET was higher than that from PCD with a significant difference of 10% to 54.8%. The detectability of hot spot imaging of PCD was lower than that of PET at 64.8% (PCD) versus 77.8% (PET). Even the actual L/B ratio was 8.0, hot spots more than 10.6 mm in diameter could be clearly identified with PCD imaging. The same identification could be achieved with PET imaging even when the actual L/B ratio was 4.0. This detailed investigation indicated that FDG PCD yielded results comparable to FDG PET on visual analysis and semi-quantitative analysis in detecting hot spots in phantoms, but semi-quantitative analysis of the L/B ratio with FDG PCD was inferior to that with FDG PET and the detectability of PCD in smaller hot spots was significantly poor. (author)

  4. An Austrian framework for PET quality control

    International Nuclear Information System (INIS)

    Nicoletti, R.; Dobrozemsky, G.; Minear, G.; Bergmann, H.

    2002-01-01

    Full text: The European patient protection directive (97/43 EURATOM) requires regular routine quality control (QC) of PET imaging devices. Since no standards were available covering this area and in order to comply with the directive a joint working party of the Austrian societies of nuclear medicine and of medical physics have developed a set of procedures suitable for both dedicated PET scanners and gamma cameras operating in coincidence mode (GCPET). The routine procedures proposed include both manufacturer recommended procedures and tests for specific parameters and calibration procedures. Wherever possible, procedures adapted or derived from NEMA standards publication NU 2-2001 were used to permit direct comparison with specified parameters of image quality. For dedicated PET scanners the most important procedures are the checking of detector sensitivities and the attenuation calibration scan. With full ring scanners the attenuation calibration scan is a blank scan, with partial ring devices a special attenuation calibration phantom has to be used. Test protocols are specific to manufacturer and scanner type. They are usually performed automatically overnight. In addition, some instruments require special calibrations, e.g. gain adjustments or coincidence timing calibration. GCPET procedures include the frequent assessment in coincidence mode of detector uniformity, energy resolution and system sensitivity. Common to both dedicated PET and GCPET are the regular quarterly assessment of tomographic spatial resolution and the calibration of the system for quantitative measurements. As a total performance test for both systems assessment of image quality following NU 2-2001 was included, to be carried out after major system changes or repairs. The suite of QC procedures was tested on several dedicated PET and GCPET systems including all major manufacturers' systems. Due to missing hardware or software not all tests could be performed on all systems. Some of the

  5. Preliminary report on the development of a high resolution PET camera using semiconductor detectors

    International Nuclear Information System (INIS)

    Kikuchi, Yohei; Ishii, Keizo; Yamazaki, Hiromichi; Matsuyama, Shigeo; Yamaguchi, Takashi; Yamamoto, Yusuke; Sato, Takemi; Aoki, Yasushi; Aoki, Kenichi

    2005-01-01

    We are developing a PET camera using small semiconductor detectors, whose resolution is equivalent to the physical limit of spatial resolution. First, a coincidence system of 16 Schottky CdTe detectors of 0.5 mm width obtained a resolution of <1 mm and it was confirmed that the Schottky CdTe detector is suitable for high resolution PET. Next, the performance of a pair of 32 channel CdTe arrays (1.2 mm width per channel) was investigated for the development of the prototype of high resolution PET. The time resolution between opposing detector pair was 13 ns (FWHM) when high voltage (700 V) was applied. The image of a 0.6 mm diameter point source was obtained in an experiment with opposing detector arrays using four channels, indicating that, a higher resolution can be achieved with the 32 channel CdTe array

  6. Clinical utility of scintimammography: From the Anger-camera to new dedicated devices

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy)]. E-mail: oschil@tiscali.it; Danieli, Roberta [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy); Romano, Pasquale [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy); Cossu, Elsa [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy); Simonetti, Giovanni [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy)

    2006-12-20

    Scintimammography is a functional imaging technique which uses a radiation detection camera to detect radionuclide tracers in the patient's breasts. Tracers are designed to accumulate in tumours more than in healthy tissue: the most used are Tc-99 m sestamibi and Tc-99 m tetrofosmin. Scintimammography is useful in some clinical indications as an adjunct to mammography: it is recommended for those lesions where additional information is required to reach a definitive diagnosis. Patients with dubious mammograms may benefit from this test, as well as women with dense breasts or with implants. Scintimammography is a valuable diagnostic tool also in patients with locally advanced breast cancer for monitoring and predicting response to neoadjuvant chemotherapy. Nevertheless, using an Anger-camera this technique shows a high sensitivity only for cancers >1 cm. Since other modalities are increasingly employed for the early identification of small abnormalities, the issue of detecting small cancers is critical for the future development and clinical utility of breast imaging with radiopharmaceuticals. The use of high-resolution cameras dedicated for breast imaging is the best option to improve the detection of small cancers: they allow higher flexibility in patient positioning, and the availability of mammography-like projections. Moreover, the detector can be placed directly in contact with the breast allowing a mild compression with reduction of the breast's thickness, thus increasing the target-to-background ratio and the sensitivity. These new devices have the potential of increasing the total number of breast scintigraphies performed thereby enhancing the role of nuclear medicine in breast cancer imaging.

  7. Characterization and performance of monolithic detector blocks with a dedicated ASIC front-end readout for PET imaging of the human brain

    International Nuclear Information System (INIS)

    Rato Mendes, Pedro; Sarasola Martin, Iciar; Canadas, Mario; Garcia de Acilu, Paz; Cuypers, Robin; Perez, Jose Manuel; Willmott, Carlos

    2011-01-01

    We are developing a human brain PET scanner prototype compatible with MRI based on monolithic scintillator crystals, APD matrices and a dedicated ASIC front-end readout. In this work we report on the performance of individual detector modules and on the operation of such modules in PET coincidence. Results will be presented on the individual characterization of detector blocks and its ASIC front-end readout, with measured energy resolutions of 13% full-width half-maximum (FWHM) at 511 keV and spatial resolutions of the order of 2 mm FWHM. First results on PET coincidence performance indicate spatial resolutions as good as 2.1 mm FWHM for SSRB/FBP reconstruction of tomographic data obtained using a simple PET demonstrator based on a pair of monolithic detector blocks with ASIC readout.

  8. F-FDG PET/CT (PET/CT) influences management in patients with known or suspected pancreatic cancer

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Kalff, Victor; Cherk, Martin H.; Yap, Kenneth SK.; Evans, Peter; Kelly, Michael J.

    2009-01-01

    Full text: Objective: To assess the impact on clinical management of PET/CT in patients with known or suspected pancreatic cancer. Methods: Between April 2006 and September 2008,25 PET/CT scans were performed using a dedicated PET/CT (22 scans) or a coincidence hybrid PET/CT camera (3 scans) in 23 patients with known or suspected pancreatic cancer. 17 scans were performed for initial evaluation and 8 for restaging of disease. The pre-PET/CT management plan and for intent were prospectively recorded in all cases. The post-PET/CT management plan was determined from the medical record and for discussions with treating clinicians. The impact of PET/CT on management was classified as High, Medium, Low or None, defined using ANZAPNM PET data collection project criteria. Follow-up was used to reconcile any discordance between PET/CT and conventional imaging. Results: Overall, PET/CT management impact was classified as high (n equal 7), medium (n equal 4), low (n equal 10) or none (n equal 4). Impact was either high or medium in l l/25 patients (44%) (95% confidence interval; 24 - 64%). Impact was high in 4/17 patients imaged for initial evaluation, predominantly by clarifying equivocal lesions on conventional imaging. In restaged patients, PET/CT impact was high in 3/8, and it correctly modified disease extent in 5/8. In the 16 discordant studies, PET/CT assessment was correct in 10, conventional imaging in 4 and there was insufficient information in 2. Conclusion: PET/CT has high or medium management impact in 44% of patients imaged for known or suspected pancreatic cancer, more commonly during restaging. Discordant PET/CT results were usually correct.

  9. Texture analysis of high-resolution dedicated breast {sup 18}F-FDG PET images correlates with immunohistochemical factors and subtype of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Moscoso, Alexis; Dominguez-Prado, Ines; Herranz, Michel; Argibay, Sonia; Silva-Rodriguez, Jesus [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); Ruibal, Alvaro [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); University of Santiago de Compostela (USC), Molecular Imaging Group, Department of Radiology, Faculty of Medicine, Santiago de Compostela (Spain); Fundacion Tejerina, Madrid (Spain); Fernandez-Ferreiro, Anxo [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Pharmacy Department and Pharmacology Group, Santiago de Compostela (Spain); Albaina, Luis [University Hospital A Coruna (SERGAS), Department of General Surgery, A Coruna (Spain); Pardo-Montero, Juan [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); Complexo Hospitalario Universitario de Santiago de Compostela (CHUS), Medical Physics Department, Santiago de Compostela (Spain); Aguiar, Pablo [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); University of Santiago de Compostela (USC), Molecular Imaging Group, Department of Radiology, Faculty of Medicine, Santiago de Compostela (Spain)

    2018-02-15

    This study aims to determine whether PET textural features measured with a new dedicated breast PET scanner reflect biological characteristics of breast tumors. One hundred and thirty-nine breast tumors from 127 consecutive patients were included in this analysis. All of them underwent a {sup 18}F-FDG PET scan before treatment. Well-known PET quantitative parameters such as SUV{sub m} {sub a} {sub x}, SUV{sub m} {sub e} {sub a} {sub n}, metabolically active tumor volume (MATV) and total lesion glycolysis (TLG) were extracted. Together with these parameters, local, regional, and global heterogeneity descriptors, which included five textural features (TF), were computed. Immunohistochemical classification of breast cancer considered five subtypes: luminal A like (LA), luminal B like/HER2 - (LB -), luminal B like/HER2+ (LB+), HER2-positive-non-luminal (HER2pnl), and triple negative (TN). Associations between PET features and tumor characteristics were assessed using non-parametric hypothesis tests. Along with well-established associations, new correlations were found. HER2-positive tumors had significantly higher uptake (p < 0.001, AUCs > 0.70) and presented different global and regional heterogeneity (p = 0.002, p = 0.016, respectively, AUCs < 0.70). Nine out of ten analyzed features were significantly associated with immunohistochemical subtype. Uptake was lower for LA tumors (p < 0.001) with AUCs ranging from 0.71 to 0.88 for each subgroup comparison. Heterogeneity metrics were significantly associated when comparing LA and LB - (p < 0.01), being regional heterogeneity metrics more discriminative than any other parameter (AUC = 0.80 compared to AUC = 0.71 for SUV). LB+ and HER2pnl tumors also showed more regional heterogeneity than LA tumors (AUCs = 0.79 and 0.84, respectively). After comparison with whole-body PET studies, we observed an overall improvement in the classification ability of both non-heterogeneity metrics and textural features. PET parameters

  10. A prototype PET/SPECT/X-rays scanner dedicated for whole body small animal studies.

    Science.gov (United States)

    Rouchota, Maritina; Georgiou, Maria; Fysikopoulos, Eleftherios; Fragogeorgi, Eirini; Mikropoulos, Konstantinos; Papadimitroulas, Panagiotis; Kagadis, George; Loudos, George

    2017-01-01

    To present a prototype tri-modal imaging system, consisting of a single photon emission computed tomography (SPET), a positron emission tomography (PET), and a computed tomography (CT) subsystem, evaluated in planar mode. The subsystems are mounted on a rotating gantry, so as to be able to allow tomographic imaging in the future. The system, designed and constructed by our group, allows whole body mouse imaging of competent performance and is currently, to the best of our knowledge, unequaled in a national and regional level. The SPET camera is based on two Position Sensitive Photomultiplier Tubes (PSPMT), coupled to a pixilated Sodium Iodide activated with Thallium (NaI(Tl)) scintillator, having an active area of 5x10cm 2 . The dual head PET camera is also based on two pairs of PSPMT, coupled to pixelated berillium germanium oxide (BGO) scintillators, having an active area of 5x10cm 2 . The X-rays system consists of a micro focus X-rays tube and a complementary metal-oxide-semiconductor (CMOS) detector, having an active area of 12x12cm 2 . The scintigraphic mode has a spatial resolution of 1.88mm full width at half maximum (FWHM) and a sensitivity of 107.5cpm/0.037MBq at the collimator surface. The coincidence PET mode has an average spatial resolution of 3.5mm (FWHM) and a peak sensitivity of 29.9cpm/0.037MBq. The X-rays spatial resolution is 3.5lp/mm and the contrast discrimination function value is lower than 2%. A compact tri-modal system was successfully built and evaluated for planar mode operation. The system has an efficient performance, allowing accurate and informative anatomical and functional imaging, as well as semi-quantitative results. Compared to other available systems, it provides a moderate but comparable performance, at a fraction of the cost and complexity. It is fully open, scalable and its main purpose is to support groups on a national and regional level and provide an open technological platform to study different detector components and

  11. [Diagnostic use of positron emission tomography in France: from the coincidence gamma-camera to mobile hybrid PET/CT devices].

    Science.gov (United States)

    Talbot, Jean-Noël

    2010-11-01

    Positron emission tomography (PET) is a well-established medical imaging method. PET is increasingly used for diagnostic purposes, especially in oncology. The most widely used radiopharmaceutical is FDG, a glucose analogue. Other radiopharmaceuticals have recently been registered or are in development. We outline technical improvements of PET machines during more than a decade of clinical use in France. Even though image quality has improved considerably and PET-CT hybrid machines have emerged, spending per examination has remained remarkably constant. Replacement and maintenance costs have remained in the range of 170-190 Euros per examination since 1997, whether early CDET gamma cameras or the latest time-of-flight PET/CT devices are used. This is mainly due to shorter acquisition times and more efficient use of FDG New reimbursement rates for PET/CT are needed in France in order to favor regular acquisition of state-of-the-art devices. One major development is the coupling of PET and MR imaging.

  12. Trends in PET imaging

    International Nuclear Information System (INIS)

    Moses, William W.

    2000-01-01

    Positron Emission Tomography (PET) imaging is a well established method for obtaining information on the status of certain organs within the human body or in animals. This paper presents an overview of recent trends PET instrumentation. Significant effort is being expended to develop new PET detector modules, especially those capable of measuring depth of interaction. This is aided by recent advances in scintillator and pixellated photodetector technology. The other significant area of effort is development of special purpose PET cameras (such as for imaging breast cancer or small animals) or cameras that have the ability to image in more than one modality (such as PET / SPECT or PET / X-Ray CT)

  13. Novel geometrical concept of a high-performance brain PET scanner. Principle, design and performance estimates

    International Nuclear Information System (INIS)

    Seguinot, J.; Braem, A.; Chesi, E.

    2006-01-01

    We present the principle, a possible implementation and performance estimates of a novel geometrical concept for a high-resolution positron emission tomograph. The concept, which can be for example implemented in a brain PET device, promises to lead to an essentially parallax-free 3D image reconstruction with excellent spatial resolution and contrast, uniform over the complete field of view. The key components are matrices of long axially oriented scintillator crystals which are read out at both extremities by segmented Hybrid Photon Detectors. We discuss the relevant design considerations for a 3D axial PET camera module, motivate parameter and material choices, and estimate its performance in terms of spatial and energy resolution. We support these estimates by Monte Carlo simulations and in some cases by first experimental results. From the performance of a camera module, we extrapolate to the reconstruction resolution of a 3D axial PET scanner in a semi-analytical way and compare it to an existing state-of-the art brain PET device. We finally describe a dedicated data acquisition system, capable to fully exploit the advantages of the proposed concept

  14. A 3D HIDAC-PET camera with sub-millimeter resolution for imaging small animals

    International Nuclear Information System (INIS)

    Jeavons, A.P.; Chandler, R.A.; Dettmar, C.A.R.

    1999-01-01

    A HIDAC-PET camera consisting essentially of 5 million 0.5 mm gas avalanching detectors has been constructed for small-animal imaging. The particular HIDAC advantage--a high 3D spatial resolution--has been improved to 0.95 mm fwhm and to 0.7 mm fwhm when reconstructing with 3D-OSEM methods incorporating resolution recovery. A depth-of-interaction resolution of 2.5 mm is implicit, due to the laminar construction. Scatter-corrected sensitivity, at 8.9 cps/kBq (i.e. 0.9%) from a central point source, or 7.2 cps/kBq (543 cps/kBq/cm 3 ) from a distributed (40 mm diameter, 60 mm long) source is now much higher than previous, and other, work. A field-of-view of 100 mm (adjustable to 200 mm) diameter by 210 mm axially permits whole-body imaging of small animals, containing typically 4MBqs of activity, at 40 kcps of which 16% are random coincidences, with a typical scatter fraction of 44%. Throughout the field-of-view there are no positional distortions and relative quantitation is uniform to ± 3.5%, but some variation of spatial resolution is found. The performance demonstrates that HIDAC technology is quite appropriate for small-animal PET cameras

  15. PET with coincidence gamma cameras - clinical benefit from the radiooncologists' point of view; PET mit Koinzidenz-Gammakameras - klinischer Nutzen aus der Sicht des Radioonkologen

    Energy Technology Data Exchange (ETDEWEB)

    Richter, E; Feyerabend, T; Stallmann, C; Lauer, I; Baehre, M [Universitaetsklinikum Luebeck (Germany). Klinik fuer Strahlentherapie und Nuklearmedizin

    2001-11-01

    Positron emission tomography with FDG (FDG-PET) is a new technique, which displays the cellular metabolic activity. Since tumors exhibit an increased metabolic activity when compared to normal tissue, this imaging modality has a particularly high importance. FDG-PET is not only useful for localizing and staging of malignant tumors, but also to evaluate therapy response. In this context, PET is superior to morphologically orientated modalities, because therapeutically induced changes in glucose metabolism precede morphologic alterations. Numerous studies indicate, that PET will play an important role in radiooncology concerning therapy planning and monitoring the effects of therapy during and after treatment. Further clinical studies are necessary to evaluate the information provided by FDG-PET more precisely. Coincidence gamma cameras with adequate imaging characteristics will gain enhanced importance to meet these increasing demands. (orig.) [German] Die Positronenemissionstomographie mit FDG (FDG-PET) ist ein neues Verfahren, das die Stoffwechselaktivitaet von Zellen bildlich wiedergibt. Da Tumorgewebe im Vergleich zu normalem Gewebe einen erhoehten Stoffwechsel aufweist, hat dieses Untersuchungsverfahren in der Onkologie einen besonders hohen Stellenwert. Neben der Lokalisations- und Ausbreitungsdiagnostik eignet sich die FDG-PET zur Erfolgsbeurteilung. Die PET ist hierin den anderen morphologischen Verfahren ueberlegen, da die Veraenderungen des Glukosemetabolismus durch therapeutische Massnahmen morphologischen Veraenderungen vorausgehen. Zahlreiche Untersuchungen lassen erkennen, dass die PET fuer die Radioonkologie einen wichtigen Stellenwert einnehmen wird. Dies betrifft die Bestrahlungsplanung und das Therapiemonitoring waehrend und nach einer Behandlung. Weitere klinische Studien sind notwendig, um die Aussagekraft der FDG-PET besser zu evaluieren. Den Koinzidenz-Gammakameras mit adaequaten Bildgebungseigenschaften kommt eine zunehmende Bedeutung zu, um

  16. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Rollo, F.D.; Hines, H.

    2001-01-01

    ADAC Laboratories has two main imaging strengths: PET and Gamma Cameras. PET's three-dimensional imaging of metabolic function is used in oncology, with emerging opportunties in cardiology, genetic mapping and pharmaceuticals research. In oncology, PET imaging can provide comprehensive and accurate staging information which is not available from CT or MRI. In some cases, this information can lead to modification of treatment, for example from an aggressive approach to one of palliation. The SKYLight is the world's first and only gantry-free camera. It is a dual-detector variable angle camera designed for high throughput, with unsurpassed openness and patient access. (orig.)

  17. Doses to nuclear technicians in a dedicated PET/CT centre utilising 18F fluorodeoxyglucose (FDG)

    International Nuclear Information System (INIS)

    Seierstad, T.; Stranden, E.; Bjering, K.; Evensen, M.; Holt, A.; Michalsen, H. M.; Wetteland, O.

    2007-01-01

    The first dedicated PET/CT centre in Norway was established at the Norwegian Radiumhospital in Oslo in 2005. Knowing that the introductions of PET-isotopes in nuclear medicine give increased occupational radiation dose to the technicians, a study was carried out in order to map the doses to staff members during different working operations and to see if any dose reducing measures were needed. The results of the study are in good agreement with other studies, and a technician dose of 20-25 nSv per injected MBq of 18 F seems to be representative for such centres. For an average injected activity of 350 MBq per patient, the dose limit is reached after handling around 3000 patients annually. For an annual number of less than 500 patients at the centre and rotation of the staff, an annual individual dose for the technicians would realistically be less than 2-3 mSv. Even a major increase in the number of patients will not result in individual doses near the ICRP dose limit. (authors)

  18. Diagnosis of myocardial viability by dual-head coincidence gamma camera fluorine-18 fluorodeoxyglucose positron emission tomography with and without non-uniform attenuation correction

    International Nuclear Information System (INIS)

    Nowak, B.; Zimmy, M.; Kaiser, H.-J.; Schaefer, W.; Reinartz, P.; Buell, U.; Schwarz, E.R.; Dahl, J. vom

    2000-01-01

    This study assessed a dual-head coincidence gamma camera (hybrid PET) equipped with single-photon transmission for myocardial fluorine-18 fluorodeoxyglucose (FDG) imaging by comparing this technique with conventional positron emission tomography (PET) using a dedicated ring PET scanner. Twenty-one patients were studied with dedicated FDG ring PET and FDG hybrid PET for evaluation of myocardial glucose metabolism, as well as technetium-99 m tetrofosmin single-photon emission tomography (SPET) to estimate myocardial perfusion. All patients underwent transmitted attenuation correction using germanium-68 rod sources for ring PET and caesium-137 point sources for hybrid PET. Ring PET and hybrid PET emission scans were started 61±12 and 98±15 min, respectively, after administration of 154±31 MBq FDG. Attenuation-corrected images were reconstructed iteratively for ring PET and hybrid PET (ac-hybrid PET), and non-attenuation-corrected images for hybrid PET (non-ac-hybrid PET) only. Tracer distribution was analysed semiquantitatively using a volumetric vector sampling method dividing the left ventricular wall into 13 segments. FDG distribution in non-ac-hybrid PET and ring PET correlated with r=0.36 (P<0.0001), and in ac-hybrid PET and ring PET with r=0.79 (P<0.0001). Non-ac-hybrid PET significantly overestimated FDG uptake in the apical and supra-apical segments, and underestimated FDG uptake in the remaining segments, with the exception of one lateral segment. Ac-hybrid PET significantly overestimated FDG uptake in the apical segment, and underestimated FDG uptake in only three posteroseptal segments. A three-grade score was used to classify diagnosis of viability by FDG PET in 136 segments with reduced perfusion as assessed by SPET. Compared with ring PET, non-ac-hybrid PET showed concordant diagnoses in 80 segments (59%) and ac-hybrid PET in 101 segments (74%) (P<0.001). Agreement between ring PET and non-ac-hybrid PET was best in the basal lateral wall and in the

  19. A Monte Carlo study of the acceptance to scattered events in a depth encoding PET camera

    International Nuclear Information System (INIS)

    Moisan, C.; Tupper, P.; Rogers, J.G.; DeJong, J.K.

    1995-10-01

    We present a Monte Carlo study of acceptance to scattered events in a Depth Encoding Large Aperture Camera (DELAC), a hypothetical PET scanner with the capacity to encode the depth-of-interaction (DOI) of incident γ-rays. The simulation is initially validated against the measured energy resolution and scatter fraction of the ECAT-953B scanner. It is then used to assess the response to scattered events in a PET camera made of position encoding blocks of the EXACT HR PLUS type, modified to have DOI resolution through a variation in the photopeak pulse height. The detection efficiency for 511 keV γ-rays, as well as for those that scattered in the object or left only part of their energy in the block, is studied for several combinations of DOI sensitivities and block thicknesses. The scatter fraction predicted by the simulation for DELACs of various ring radii is compared to that of the ECAT-953B as a function of the energy threshold. The results indicate that the poorer discrimination of object scatters with depth sensitive blocks does not lead to a dramatic increase of the scatter fraction. (author). 10 refs., 1 tab., 5 figs

  20. First full-beam PET acquisitions in proton therapy with a modular dual-head dedicated system

    Science.gov (United States)

    Sportelli, G.; Belcari, N.; Camarlinghi, N.; Cirrone, G. A. P.; Cuttone, G.; Ferretti, S.; Kraan, A.; Ortuño, J. E.; Romano, F.; Santos, A.; Straub, K.; Tramontana, A.; Del Guerra, A.; Rosso, V.

    2014-01-01

    During particle therapy irradiation, positron emitters with half-lives ranging from 2 to 20 min are generated from nuclear processes. The half-lives are such that it is possible either to detect the positron signal in the treatment room using an in-beam positron emission tomography (PET) system, right after the irradiation, or to quickly transfer the patient to a close PET/CT scanner. Since the activity distribution is spatially correlated with the dose, it is possible to use PET imaging as an indirect method to assure the quality of the dose delivery. In this work, we present a new dedicated PET system able to operate in-beam. The PET apparatus consists in two 10 cm × 10 cm detector heads. Each detector is composed of four scintillating matrices of 23 × 23 LYSO crystals. The crystal size is 1.9 mm × 1.9 mm × 16 mm. Each scintillation matrix is read out independently with a modularized acquisition system. The distance between the two opposing detector heads was set to 20 cm. The system has very low dead time per detector area and a 3 ns coincidence window, which is capable to sustain high single count rates and to keep the random counts relatively low. This allows a new full-beam monitoring modality that includes data acquisition also while the beam is on. The PET system was tested during the irradiation at the CATANA (INFN, Catania, Italy) cyclotron-based proton therapy facility. Four acquisitions with different doses and dose rates were analysed. In all cases the random to total coincidences ratio was equal or less than 25%. For each measurement we estimated the accuracy and precision of the activity range on a set of voxel lines within an irradiated PMMA phantom. Results show that the inclusion of data acquired during the irradiation, referred to as beam-on data, improves both the precision and accuracy of the range measurement with respect to data acquired only after irradiation. Beam-on data alone are enough to give precisions better than 1 mm

  1. First full-beam PET acquisitions in proton therapy with a modular dual-head dedicated system

    International Nuclear Information System (INIS)

    Sportelli, G; Belcari, N; Camarlinghi, N; Ferretti, S; Kraan, A; Straub, K; Guerra, A Del; Rosso, V; Cirrone, G A P; Cuttone, G; Romano, F; Tramontana, A; Ortuño, J E; Santos, A

    2014-01-01

    During particle therapy irradiation, positron emitters with half-lives ranging from 2 to 20 min are generated from nuclear processes. The half-lives are such that it is possible either to detect the positron signal in the treatment room using an in-beam positron emission tomography (PET) system, right after the irradiation, or to quickly transfer the patient to a close PET/CT scanner. Since the activity distribution is spatially correlated with the dose, it is possible to use PET imaging as an indirect method to assure the quality of the dose delivery. In this work, we present a new dedicated PET system able to operate in-beam. The PET apparatus consists in two 10 cm × 10 cm detector heads. Each detector is composed of four scintillating matrices of 23 × 23 LYSO crystals. The crystal size is 1.9 mm × 1.9 mm × 16 mm. Each scintillation matrix is read out independently with a modularized acquisition system. The distance between the two opposing detector heads was set to 20 cm. The system has very low dead time per detector area and a 3 ns coincidence window, which is capable to sustain high single count rates and to keep the random counts relatively low. This allows a new full-beam monitoring modality that includes data acquisition also while the beam is on. The PET system was tested during the irradiation at the CATANA (INFN, Catania, Italy) cyclotron-based proton therapy facility. Four acquisitions with different doses and dose rates were analysed. In all cases the random to total coincidences ratio was equal or less than 25%. For each measurement we estimated the accuracy and precision of the activity range on a set of voxel lines within an irradiated PMMA phantom. Results show that the inclusion of data acquired during the irradiation, referred to as beam-on data, improves both the precision and accuracy of the range measurement with respect to data acquired only after irradiation. Beam-on data alone are enough to give precisions better than 1

  2. Molecular imaging of small animals with dedicated PET tomographs

    International Nuclear Information System (INIS)

    Chatziioannou, A.F.

    2002-01-01

    Biological discovery has moved at an accelerated pace in recent years, with a considerable focus on the transition from in vitro to in vivo models. As a result, there has been a significant increase in the need to adapt clinical imaging methods, as well as for novel imaging technologies for biological research. Positron emission tomography (PET) is a clinical imaging modality that permits the use of positron-labeled molecular imaging probes for non-invasive assays of biochemical processes. The imaging procedure can be repeatedly performed before and after interventions, thereby allowing each animal to be used as its own control. Positron-labeled compounds that target a range of molecular targets have been and continue to be synthesized, with examples of biological processes ranging from receptors and synthesis of transmitters in cell communication, to metabolic processes and gene expression. In animal research, PET has been used extensively in the past for studies of non-human primates and other larger animals. New detector technology has improved spatial resolution, and has made possible PET scanning for the study of the most important modern molecular biology model, the laboratory mouse. This paper presents the challenges facing PET technology as applied to small animal imaging, provides a historical overview of the development of small animal PET systems, and discusses the current state of the art in small animal PET technology. (orig.)

  3. Value of F-18 FDG hybrid camera PET and MRI in early takayasu aortitis

    Energy Technology Data Exchange (ETDEWEB)

    Meller, J.; Becker, W. [Department of Nuclear Medicine, Georg August University, Robert Koch Strasse 40, 37075 Goettingen (Germany); Grabbe, E.; Vosshenrich, R. [Department of Radiology, Georg August University, Robert Koch Strasse 40, 37075 Goettingen (Germany)

    2003-02-01

    Takayasu aortitis (TA) is a chronic inflammatory and fibrotic vasculitis of large- and medium-sized arteries. Early stages of the disease show a panarteritis and inflammatory wall thickening of the aorta and its branches, whereas advanced (fibrotic) stages comprise stenosis, aneurismatic transformation and occlusion. Magnetic resonance imaging visualises early-stage disease with high accuracy and is considered to be the method of choice in the diagnosis of TA. The aim of this article is the detailed comparison of FDG-PET performed with a hybrid camera and MR imaging in five patients with early TA. Five patients (median age 60 years) were enrolled during an ongoing prospective study on [18F]2'-deoxy-2-fluoro-D-glucose (FDG) hybrid camera PET in patients with fever of unknown origin (FUO). These patients underwent MR imaging after establishing the diagnosis of TA. Abnormal FDG uptake in the wall of the aorta was noted in all patients. The bracheocephalic artery and the common carotid arteries were visualized in 3 cases. Increased uptake of the subclavian artery was found in 3 patients and in 4 patients pathological uptake was noted in the ilio-femoral vessels. Of 34 vascular regions studied, 26 (76%) showed elevated FDG uptake. On transversal MR images vessel wall thickening and contrast enhancement of the thoracic aorta was found in 4 patients (ascending aorta/aortic arch: n=2; descending aorta: n=3; abdominal aorta: n=1). Additionally, vessel wall pathologies of the subclavian and the common carotid arteries could be shown in 1 patient and in another patient in the ilio-femoral arteries. No abnormalities were found using contrast-enhanced MR angiography. Of 28 vascular regions studied, 9 (32%) showed vasculitis on MRI. The FDG-PET is a suitable whole-body screening method in the primary diagnosis of early TA, especially in those cases with early disease that present with uncharacteristic symptoms such as FUO. Both MRI and MRA remain indispensable in the exact

  4. Value of F-18 FDG hybrid camera PET and MRI in early takayasu aortitis

    International Nuclear Information System (INIS)

    Meller, J.; Becker, W.; Grabbe, E.; Vosshenrich, R.

    2003-01-01

    Takayasu aortitis (TA) is a chronic inflammatory and fibrotic vasculitis of large- and medium-sized arteries. Early stages of the disease show a panarteritis and inflammatory wall thickening of the aorta and its branches, whereas advanced (fibrotic) stages comprise stenosis, aneurismatic transformation and occlusion. Magnetic resonance imaging visualises early-stage disease with high accuracy and is considered to be the method of choice in the diagnosis of TA. The aim of this article is the detailed comparison of FDG-PET performed with a hybrid camera and MR imaging in five patients with early TA. Five patients (median age 60 years) were enrolled during an ongoing prospective study on [18F]2'-deoxy-2-fluoro-D-glucose (FDG) hybrid camera PET in patients with fever of unknown origin (FUO). These patients underwent MR imaging after establishing the diagnosis of TA. Abnormal FDG uptake in the wall of the aorta was noted in all patients. The bracheocephalic artery and the common carotid arteries were visualized in 3 cases. Increased uptake of the subclavian artery was found in 3 patients and in 4 patients pathological uptake was noted in the ilio-femoral vessels. Of 34 vascular regions studied, 26 (76%) showed elevated FDG uptake. On transversal MR images vessel wall thickening and contrast enhancement of the thoracic aorta was found in 4 patients (ascending aorta/aortic arch: n=2; descending aorta: n=3; abdominal aorta: n=1). Additionally, vessel wall pathologies of the subclavian and the common carotid arteries could be shown in 1 patient and in another patient in the ilio-femoral arteries. No abnormalities were found using contrast-enhanced MR angiography. Of 28 vascular regions studied, 9 (32%) showed vasculitis on MRI. The FDG-PET is a suitable whole-body screening method in the primary diagnosis of early TA, especially in those cases with early disease that present with uncharacteristic symptoms such as FUO. Both MRI and MRA remain indispensable in the exact

  5. Reconstruction in PET cameras with irregular sampling and depth of interaction capability

    International Nuclear Information System (INIS)

    Virador, P.R.G.; Moses, W.W.; Huesman, R.H.

    1998-01-01

    The authors present 2D reconstruction algorithms for a rectangular PET camera capable of measuring depth of interaction (DOI). The camera geometry leads to irregular radial and angular sampling of the tomographic data. DOI information increases sampling density, allowing the use of evenly spaced quarter-crystal width radial bins with minimal interpolation of irregularly spaced data. In the regions where DOI does not increase sampling density (chords normal to crystal faces), fine radial sinogram binning leads to zero efficiency bins if uniform angular binning is used. These zero efficiency sinogram bins lead to streak artifacts if not corrected. To minimize these unnormalizable sinogram bins the authors use two angular binning schemes: Fixed Width and Natural Width. Fixed Width uses a fixed angular width except in the problem regions where appropriately chosen widths are applied. Natural Width uses angle widths which are derived from intrinsic detector sampling. Using a modified filtered-backprojection algorithm to accommodate these angular binning schemes, the authors reconstruct artifact free images with nearly isotropic and position independent spatial resolution. Results from Monte Carlo data indicate that they have nearly eliminated image degradation due to crystal penetration

  6. Integration of gamma cameras and PET devices of multiple vendors in several locations

    International Nuclear Information System (INIS)

    Dresel, S.; Vollmar, C.; Sengupta, S.; Hahn, K.

    2002-01-01

    Full text: The Department of Nuclear Medicine of the University of Munich consists of four independently operated locations with a total of 18 gamma cameras (of three vendors), one PET scanner and one coincidence gamma camera. Recent hardware improvements, the installation and development of fast networks and new technologies for storage of large data volumes all contribute to the propagation of digital reading and reporting of nuclear medicine studies. Thus, the vision of a fully digitized nuclear medicine department becomes reality. In 1997 the department started with a strategy to fully integrate the entire number of imaging devices into one network for filmless reading, archiving and distributing nuclear medicine studies throughout the hospitals. The decision was made to use HERMES workstations (Nuclear Diagnostics, Sweden) to connect all primary imaging modalities. The purpose of the workstations located in the Nuclear Medicine departments is threefold: postprocessing, reading and archiving of all data. The workstations are networked throughout the different hospitals and are able to read the proprietary or DICOM data of the vendors of the gamma camera and PET equipment. The HERMES system is connected via DICOM interface to a long term storage device (AGFA, Germany). Additionally a JAVA (SUN Microsystems, USA) based software (JARVIS, Nuclear Diagnostics) is available to view all data from any computer using a web browser. Furthermore all data is linked to the hospital information system and selected imaging data are distributed throughout the hospitals. After commencement of full service of the network in 2000 the department is over 95 % filmfree. The high costs of purchasing hardware- and software-components are compensated for by saving costs of films and by the improvement of the work flow. Independently from these issues, filmless reporting proves to be advantageous over conventional film reading in many facts that justify to switch to a digital department

  7. Feasibility of a brain-dedicated PET-MRI system using four-layer DOI detectors integrated with an RF head coil

    International Nuclear Information System (INIS)

    Nishikido, F.; Obata, T.; Shimizu, K.; Suga, M.; Inadama, N.; Tachibana, A.; Yoshida, E.; Ito, H.; Yamaya, T.

    2014-01-01

    We are developing a PET-MRI system which consists of PET detectors integrated with the head coil of the MRI in order to realize high spatial resolution and high sensitivity in simultaneous measurements. In the PET-MRI system, the PET detectors which consist of a scintillator block, photo-detectors and front-end circuits with four-layer depth-of-interaction (DOI) encoding capability are placed close to the measured object. Therefore, the proposed system can achieve high sensitivity without degradation of spatial resolution at the edge of the field-of-view due to parallax error thanks to the four-layer DOI capability. In this paper, we fabricated a prototype system which consists of a prototype four-layer DOI-PET detector, a dummy PET detector and a prototype birdcage type head coil. Then we used the prototype system to evaluate the performance of the four-layer DOI-PET detector and the reciprocal influence between the PET detectors and MRI images. The prototype DOI-PET detector consists of six monolithic multi-pixel photon counter (MPPC) arrays (S11064-050P), a readout circuit board, two scintillator blocks and a copper shielding box. Each scintillator block consists of four layers of Lu 1.8 Gd 0.2 SiO 5 :Ce (LGSO) scintillators and reflectors are inserted between the scintillation crystals. The dummy detector has all these components except the two scintillator blocks. The head coil is dedicated to a 3.0 T MRI (MAGNETOM Verio, Siemens) and the two detectors are mounted in gaps between head coil elements. Energy resolution and crystal identification performance of the prototype four-layer DOI-PET detector were evaluated with and without MRI measurements by the gradient echo and spin echo methods. We identified crystal elements in all four layers from a 2D flood histogram and energy resolution of 15–18% was obtained for single crystal elements in simultaneous measurements. The difference between the average energy resolutions and photo-peak positions with and

  8. Microeconomics of introduction of a PET system based on the revised Japanese national insurance reimbursement system

    International Nuclear Information System (INIS)

    Abe, Katsumi; Kosuda, Shigeru; Kusano, Shoichi; Nagata, Masayoshi

    2003-01-01

    It is crucial to evaluate an annual balance beforehand when an institution installs a PET system because the revised Japanese national insurance reimbursement system set the cost of a FDG PET study as 75,000 yen. A break-even point was calculated in an 8-hour or a 24-hour operation of a PET system, based on the total costs reported. The break-even points were as follows: 13.4, 17.7, 22.1 studies per day for the 1 cyclotron-1 PET camera, 1 cyclotron-2 PET cameras, 1 cyclotron-3 PET cameras system, respectively, in an ordinary PET system operation of 8 hours. The break-even points were 19.9, 25.5, 31.2 studies per day for the 1 cyclotron-1 PET camera, 1 cyclotron-2 PET cameras, 1 cyclotron-3 PET cameras system, respectively, in a full PET system operation of 24 hours. The results indicate no profit would accrue in an ordinary PET system operation of 8 hours. The annual profit and break-even point for the total cost including the initial investment would be respectively 530 million yen and 2.8 years in a 24-hour operation with 1 cyclotron-3 PET cameras system. (author)

  9. [Microeconomics of introduction of a PET system based on the revised Japanese National Insurance reimbursement system].

    Science.gov (United States)

    Abe, Katsumi; Kosuda, Shigeru; Kusano, Shoichi; Nagata, Masayoshi

    2003-11-01

    It is crucial to evaluate an annual balance before-hand when an institution installs a PET system because the revised Japanese national insurance reimbursement system set the cost of a FDG PET study as 75,000 yen. A break-even point was calculated in an 8-hour or a 24-hour operation of a PET system, based on the total costs reported. The break-even points were as follows: 13.4, 17.7, 22.1 studies per day for the 1 cyclotron-1 PET camera, 1 cyclotron-2 PET cameras, 1 cyclotron-3 PET cameras system, respectively, in an ordinary PET system operation of 8 hours. The break-even points were 19.9, 25.5, 31.2 studies per day for the 1 cyclotron-1 PET camera, 1 cyclotron-2 PET cameras, 1 cyclotron-3 PET cameras system, respectively, in a full PET system operation of 24 hours. The results indicate no profit would accrue in an ordinary PET system operation of 8 hours. The annual profit and break-even point for the total cost including the initial investment would be respectively 530 million yen and 2.8 years in a 24-hour operation with 1 cyclotron-3 PET cameras system.

  10. Evaluation of pulmonary lesions with 18FDG CoDo PET: comparison with CT, MRI and clinical findings

    International Nuclear Information System (INIS)

    Kim, Su Zy; Park, Chan Hee; Han, Myung Ho; Hwang, Sung Chul; Lee, Chul Joo; Pai, Moon Sun

    1998-01-01

    Dual-head gamma camera coincidence (PET) is one of the recent approaches to overcome the problems of the dedicated PET scans such as high cost and limited availability. The purpose of this study was to evaluate the accuracy of 18 FDG coincidence detection (CoDe) PET in differentiating benign from malignant lesions and staging malignancy. Thirty-one patients with pulmonary lesions underwent 18 FDG CoDe PET. Patients were prepared for the study by overnight fasting. The images were acquired at about 1 hr postinjection of 3-10 mCi 18 FDG intravenously using dual head gamma camera (Elscint, Varicam) equipped with 5/8 inch thick NaI crystal. The images were analyzed visually. Pathologic proof of diagnosis was obtained by aspiration biopsy in 24 patients and by operation in 7 patients. Among 25 patients with pathologically proven malignant lesions ( 11 adenocarcinoma, 3 non-small cell lung cancer, 5 squamous cell cancer, 4 small cell lung cancer, 1 invasive thymoma and 1 adenosquamous cell cancer), 18 FDG CoDe PET could not detect only 1 lesion which was adenocarcinoma of less than 1 cm in size. In seven patients underwent lobectomy, 6 CoDe PET studies agreed with pathologic results. Whereas only 3 of 7 patients CT findings agreed with pathologic findings. However, 6 patients with benign lesions also showed positive FDG uptake. The false positive pathologies were due to tuberculosis, pneumonia, and granulomatous changes due to silicosis. 18 FDG CoDe PET was sensitive in the evaluation of lung lesions but was not specific for malignancy. 18 FDG CoDe PET was more sensitive than CT in nodal staging in limited number of patients studied thus far

  11. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  12. The use of a Micromegas as a detector for gamma camera

    International Nuclear Information System (INIS)

    Barbouchi, Asma; Trabelsi, Adel

    2008-01-01

    The micromegas (Micro Mesh Gaseaous) is a gas detector; it was developed by I.Giomattaris and G.Charpak for application in the field of experimental particle physics. But the polyvalence of this detector makes it to be used in several areas such as medical imaging. This detector has an X-Y readout capability of resolution less than 100μm, an energy resolution down to 14% for energy range 1-10 keV and an overall efficiency of 70%. Monte carlo simulation is widely used in nuclear medicine. It allows predicting the behaviour of system. Gate (Geant4 for Application Tomography Emission) is a platform for monte carlo simulation. It is dedicated to PET/SPECT (Position Emission Tomography / single Photon Emission Tomography) applications. Our goal is to model a gamma camera that use a Micromegas as a detector and to compare their performances (energy resolution, point spread function...) with those of a scintillated gamma camera by using Gate

  13. Gamma camera based Positron Emission Tomography: a study of the viability on quantification

    International Nuclear Information System (INIS)

    Pozzo, Lorena

    2005-01-01

    Positron Emission Tomography (PET) is a Nuclear Medicine imaging modality for diagnostic purposes. Pharmaceuticals labeled with positron emitters are used and images which represent the in vivo biochemical process within tissues can be obtained. The positron/electron annihilation photons are detected in coincidence and this information is used for object reconstruction. Presently, there are two types of systems available for this imaging modality: the dedicated systems and those based on gamma camera technology. In this work, we utilized PET/SPECT systems, which also allows for the traditional Nuclear Medicine studies based on single photon emitters. There are inherent difficulties which affect quantification of activity and other indices. They are related to the Poisson nature of radioactivity, to radiation interactions with patient body and detector, noise due to statistical nature of these interactions and to all the detection processes, as well as the patient acquisition protocols. Corrections are described in the literature and not all of them are implemented by the manufacturers: scatter, attenuation, random, decay, dead time, spatial resolution, and others related to the properties of each equipment. The goal of this work was to assess these methods adopted by two manufacturers, as well as the influence of some technical characteristics of PET/SPECT systems on the estimation of SUV. Data from a set of phantoms were collected in 3D mode by one camera and 2D, by the other. We concluded that quantification is viable in PET/SPECT systems, including the estimation of SUVs. This is only possible if, apart from the above mentioned corrections, the camera is well tuned and coefficients for sensitivity normalization and partial volume corrections are applied. We also verified that the shapes of the sources used for obtaining these factors play a role on the final results and should be delt with carefully in clinical quantification. Finally, the choice of the region

  14. Breast Imaging Utilizing Dedicated Gamma Camera and (99m)Tc-MIBI: Experience at the Tel Aviv Medical Center and Review of the Literature Breast Imaging.

    Science.gov (United States)

    Even-Sapir, Einat; Golan, Orit; Menes, Tehillah; Weinstein, Yuliana; Lerman, Hedva

    2016-07-01

    The scope of the current article is the clinical role of gamma cameras dedicated for breast imaging and (99m)Tc-MIBI tumor-seeking tracer, as both a screening modality among a healthy population and as a diagnostic modality in patients with breast cancer. Such cameras are now commercially available. The technology utilizing a camera composed of a NaI (Tl) detector is termed breast-specific gamma imaging. The technology of dual-headed camera composed of semiconductor cadmium zinc telluride detectors that directly converts gamma-ray energy into electronic signals is termed molecular breast imaging. Molecular breast imaging system has been installed at the Department of Nuclear medicine at the Tel Aviv Sourasky Medical Center, Tel Aviv in 2009. The article reviews the literature well as our own experience. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Validation of a Multimodality Flow Phantom and Its Application for Assessment of Dynamic SPECT and PET Technologies.

    Science.gov (United States)

    Gabrani-Juma, Hanif; Clarkin, Owen J; Pourmoghaddas, Amir; Driscoll, Brandon; Wells, R Glenn; deKemp, Robert A; Klein, Ran

    2017-01-01

    Simple and robust techniques are lacking to assess performance of flow quantification using dynamic imaging. We therefore developed a method to qualify flow quantification technologies using a physical compartment exchange phantom and image analysis tool. We validate and demonstrate utility of this method using dynamic PET and SPECT. Dynamic image sequences were acquired on two PET/CT and a cardiac dedicated SPECT (with and without attenuation and scatter corrections) systems. A two-compartment exchange model was fit to image derived time-activity curves to quantify flow rates. Flowmeter measured flow rates (20-300 mL/min) were set prior to imaging and were used as reference truth to which image derived flow rates were compared. Both PET cameras had excellent agreement with truth ( [Formula: see text]). High-end PET had no significant bias (p > 0.05) while lower-end PET had minimal slope bias (wash-in and wash-out slopes were 1.02 and 1.01) but no significant reduction in precision relative to high-end PET ( 0.3). SPECT (without scatter and attenuation corrections) slope biases were noted (0.85 and 1.32) and attributed to camera saturation in early time frames. Analysis of wash-out rates from non-saturated, late time frames resulted in excellent agreement with truth ( [Formula: see text], slope = 0.97). Attenuation and scatter corrections did not significantly impact SPECT performance. The proposed phantom, software and quality assurance paradigm can be used to qualify imaging instrumentation and protocols for quantification of kinetic rate parameters using dynamic imaging.

  16. Performance Evaluation of a Dedicated Preclinical PET/CT System for the Assessment of Mineralization Process in a Mouse Model of Atherosclerosis.

    Science.gov (United States)

    Rucher, Guillaume; Cameliere, Lucie; Fendri, Jihene; Abbas, Ahmed; Dupont, Kevin; Kamel, Said; Delcroix, Nicolas; Dupont, Axel; Berger, Ludovic; Manrique, Alain

    2018-04-30

    The purpose of this study was to assess the impact of positron emission tomography/X-ray computed tomography (PET/CT) acquisition and reconstruction parameters on the assessment of mineralization process in a mouse model of atherosclerosis. All experiments were performed on a dedicated preclinical PET/CT system. CT was evaluated using five acquisition configurations using both a tungsten wire phantom for in-plane resolution assessment and a bar pattern phantom for cross-plane resolution. Furthermore, the radiation dose of these acquisition configurations was calculated. The PET system was assessed using longitudinal line sources to determine the optimal reconstruction parameters by measuring central resolution and its coefficient of variation. An in vivo PET study was performed using uremic ApoE -/- , non-uremic ApoE -/- , and control mice to evaluate optimal PET reconstruction parameters for the detection of sodium [ 18 F]fluoride (Na[ 18 F]F) aortic uptake and for quantitative measurement of Na[ 18 F]F bone influx (Ki) with a Patlak analysis. For CT, the use of 1 × 1 and 2 × 2 binning detector mode increased both in-plane and cross-plane resolution. However, resolution improvement (163 to 62 μm for in-plane resolution) was associated with an important radiation dose increase (1.67 to 32.78 Gy). With PET, 3D-ordered subset expectation maximization (3D-OSEM) algorithm increased the central resolution compared to filtered back projection (1.42 ± 0.35 mm vs. 1.91 ± 0.08, p PET resolution for preclinical study (FWHM = 0.98 mm). These PET reconstruction parameters allowed the detection of Na[ 18 F]F aortic uptake in 3/14 ApoE -/- mice and demonstrated a decreased Ki in uremic ApoE -/- compared to non-uremic ApoE -/- and control mice (p PET. In addition, improving the CT resolution was associated with a dramatic radiation dose increase.

  17. PET/CT and dedicated PET in breast cancer: Implications for classification, staging, and response monitoring

    NARCIS (Netherlands)

    Koolen, B.B.

    2013-01-01

    De PET-CT, een scan die gebruik maakt van radioactiviteit om tumoren in beeld te brengen, is een zinvol instrument voor beeldvorming van patiënten met borstkanker, met name van patiënten met een tumor groter dan drie centimeter of tumor-positieve lymfeklieren. De PET-CT is vooral van waarde voor de

  18. Methodology for predicting the characteristics and performance of different PET camera designs: The choice of figures of merit

    International Nuclear Information System (INIS)

    Deconinck, F.; Defrise, M.; Kuyk, S.; Bossuyt, A.

    1985-01-01

    In order to compare different PET camera designs (ring and planar geometry), this paper proposes ''figures of merit which allow questions such as ''Is it better, given an particular design, to achieve a coincidence rate of 10 kHz with 5% randoms, or a 20 kHz rate with 10% randoms?'' to be answered. The authors propose a methodology based on information theory. The image is the three dimensional distribution which conveys the information to the human or electronic observer. The image is supposed to consist of discrete image elements (voxels) of uniform size, and each characterized by a coincidence density. The performance of a non-ideal imager can be studied by evaluating the effect on the visibility surface: the number of events per image element will be affected by the limited efficiency, geometrical acceptance angle, temporal resolution, energy resolution. The authors show that the effect of the degradations can be introduced in the formula by replacing the number of true coincidences by an effective number of coincidences. The non-ideal imager will distort the visibility surface, so the authors compare the performance of different PET cameras by comparing the different distortions which they induce and hence their ability to detect the information present in study objects

  19. SmartPET: Applying HPGe and pulse shape analysis to small-animal PET

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.J. [Department of Physics, University of Liverpool (United Kingdom)], E-mail: rjc@ns.ph.liv.ac.uk; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Grint, A.N.; Mather, A.R.; Nolan, P.J.; Scraggs, D.P.; Turk, G. [Department of Physics, University of Liverpool (United Kingdom); Hall, C.J.; Lazarus, I. [CCLRC Daresbury Laboratory, Warrington, Cheshire (United Kingdom); Berry, A.; Beveridge, T.; Gillam, J.; Lewis, R.A. [School of Physics and Materials Engineering, Monash University, Melbourne (Australia)

    2007-08-21

    The SmartPET project is the development of a prototype small-animal imaging system based on the use of Hyperpure Germanium (HPGe) detectors. The use of digital electronics and application of Pulse Shape Analysis (PSA) techniques provide fine spatial resolution, while the excellent intrinsic energy resolution of HPGe detectors makes the system ideal for multi-nuclide imaging. As a result, the SmartPET system has the potential to function as a dual modality imager, operating as a dual-head Positron Emission Tomography (PET) camera or in a Compton Camera configuration for Single Photon Emission Computed Tomography (SPECT) imaging. In this paper, we discuss how the use of simple PSA techniques greatly improves the position sensitivity of the detector yielding improved spatial resolution in reconstructed images. The PSA methods presented have been validated by comparison to data from high-precision scanning of the detectors. Results from this analysis are presented along with initial images from the SmartPET system, which demonstrates the impact of these techniques on PET images.

  20. Present and future aspects of PET examinations

    International Nuclear Information System (INIS)

    Inoue, Tomio

    2003-01-01

    The PET examination gives the body distribution image of a compound labeled with the positron emitter manufactured by cyclotron. Recently, PET with F18-deoxyglucose (FDG) attracts considerable attention because the imaging is particularly useful for cancer detection. Since the technique was authorized by the United States (US) official health insurance in 1998, the number of the examination is increasing, which is also under similar situation in Japan due to the latest partial authorization for some malignant tumors. In Japan, about 30,000 examinations per year are carried out, half of which, in private hospitals. Their purpose is increasingly for cancer detection. For future PET examination, awaited are improvement of PET camera and development of a novel imaging agent. PET/CT imaging is for the former and F18-α-methyltyrosine, for the latter. Miniaturization of cyclotron, FDG delivery system, improved FDG synthetic method, popularization of PET/CT, development of PET camera for health examination, clinical trial of a novel imaging agent, and spread of PET health examination and operation of PET Center, are expected for future progress of PET technique. (N.I.)

  1. Evaluation of pulmonary lesions with {sup 18}FDG CoDo PET: comparison with CT, MRI and clinical findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Su Zy; Park, Chan Hee; Han, Myung Ho; Hwang, Sung Chul; Lee, Chul Joo; Pai, Moon Sun [College of Medicine, Ajou Univ., Suwon (Korea, Republic of)

    1998-07-01

    Dual-head gamma camera coincidence (PET) is one of the recent approaches to overcome the problems of the dedicated PET scans such as high cost and limited availability. The purpose of this study was to evaluate the accuracy of {sup 18}FDG coincidence detection (CoDe) PET in differentiating benign from malignant lesions and staging malignancy. Thirty-one patients with pulmonary lesions underwent {sup 18}FDG CoDe PET. Patients were prepared for the study by overnight fasting. The images were acquired at about 1 hr postinjection of 3-10 mCi {sup 18}FDG intravenously using dual head gamma camera (Elscint, Varicam) equipped with 5/8 inch thick NaI crystal. The images were analyzed visually. Pathologic proof of diagnosis was obtained by aspiration biopsy in 24 patients and by operation in 7 patients. Among 25 patients with pathologically proven malignant lesions ( 11 adenocarcinoma, 3 non-small cell lung cancer, 5 squamous cell cancer, 4 small cell lung cancer, 1 invasive thymoma and 1 adenosquamous cell cancer), {sup 18}FDG CoDe PET could not detect only 1 lesion which was adenocarcinoma of less than 1 cm in size. In seven patients underwent lobectomy, 6 CoDe PET studies agreed with pathologic results. Whereas only 3 of 7 patients CT findings agreed with pathologic findings. However, 6 patients with benign lesions also showed positive FDG uptake. The false positive pathologies were due to tuberculosis, pneumonia, and granulomatous changes due to silicosis. {sup 18}FDG CoDe PET was sensitive in the evaluation of lung lesions but was not specific for malignancy. {sup 18}FDG CoDe PET was more sensitive than CT in nodal staging in limited number of patients studied thus far.

  2. Performances evaluation of the coincidence detection on a gamma-camera

    International Nuclear Information System (INIS)

    Dreuille, O. de; Gaillard, J.F.; Brasse, D.; Bendriem, B.; Groiselle, C.; Rocchisani, J.M.; Moretti, J.L.

    2000-01-01

    The performance of the VERTEX gamma-camera (ADAC) working in coincidence mode are investigated using a protocol derived from the NEMA and IEC recommendations. With a field of view determined by two rectangular detectors (50.8 cm x 40 cm) composed of NaI crystal, this camera allows a 3-D acquisition with different energy window configurations: photopeak-photopeak only (PP) and photopeak-photopeak + photopeak-Compton (PC). An energy resolution of 11% and a scatter fraction of 27% and 33% for the 3D-PP and 3D-PC mode respectively are the main significant results of our study. The spatial resolution equals 5.9 mm and the limit of the detectability ranges from 16 mm to 13 mm for a contrast of 2.5: as a function of the random estimation, the maximum of the Noise Equivalent Count rate varies from 3 kcps to 4.5 kcps for the PP mode and from 3.85 kcps to 6.1 kcps for the PC mode. These maxima are reached for a concentration of 8 kBq/ml for the PP mode and 5 kBq/ml for the PC mode. These values are compared with the results obtained by other groups for the VERTEX gamma camera and several dedicated PET systems. (authors)

  3. Usefulness of Integrated PET/MRI in Head and Neck Cancer: A Preliminary Study

    International Nuclear Information System (INIS)

    Lee, Soo Jin; Seo, Hyo Jung; Cheon, Gi Jeong; Kim, Ji Hoon; Kim, E. Edmund; Kang, Keon Wook; Paeng, Jin Chul; Chung, Junekey; Lee, Dong Soo

    2014-01-01

    The new modality of an integrated positron emission tomography/magnetic resonance imaging (PET/MRI) has recently been introduced but not validated. Our objective was to evaluate clinical performance of 18 F-fluoro-2-deoxyglucose ( 18 F-FDG) PET/MRI in patients with head and neck cancer. This retrospective study was conducted between January 2013 and February 2013. Ten patients (eight men, two women; mean age, 61.4±13.4 years) with histologically proven head and neck tumors were enrolled.Whole-body PET/MRI and regional positron emission tomography (PET) with dedicated MRI were sequentially obtained. Maximum standardized uptake value (SUVmax), SUVmean, metabolic tumor volume, total lesion glycolysis and contrast enhancement were analyzed. A total of ten whole-body positron emission tomography (PET), ten regional positron emission tomography (PET), ten dedicated MRI and ten regional PET/gadolinium-enhanced T1-weighted (Gd)-MRI images were analyzed for initial staging. Two nuclear medicine physicians analyzed positron emission tomography (PET) and PET/MRI with a consensus. One radiologist analyzed dedicated MRI. The primary lesions and number of metastatic lymph nodes analyzed from each image were compared. Eight patients were diagnosed with head and neck cancer (one tongue cancer, four tonsillar cancers, one nasopharyngeal cancer and two hypopharyngeal cancers) by histological diagnosis. Two benign tumors (pleomorphic adenoma and Warthin tumor) were diagnosed with surgical operation. Whole-body positron emission tomography (PET) and regional positron emission tomography (PET) attenuated by MRI showed good image quality for the lesion detection. Whole-body positron emission tomography (PET) and regional positron emission tomography (PET) detected ten primary sites and compensated for a missed lesion on dedicated MRI. A discordant number of suspicious lymph node metastases was noted according to the different images; 22, 16, 39 and 40 in the whole-body positron

  4. Thermal regulation of tightly packed solid-state photodetectors in a 1 mm{sup 3} resolution clinical PET system

    Energy Technology Data Exchange (ETDEWEB)

    Freese, D. L.; Vandenbroucke, A.; Innes, D.; Lau, F. W. Y.; Hsu, D. F. C.; Reynolds, P. D.; Levin, Craig S., E-mail: cslevin@stanford.edu [Departments of Electrical Engineering, Radiology, Physics, and BioEngineering, Stanford University, Stanford, California 94305-5128 (United States)

    2015-01-15

    Purpose: Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. PET system designs with high photodetector density suffer both increased thermal density and constrained options for thermally regulating the devices. This paper proposes a method of thermally regulating densely packed silicon photodetectors in the context of a 1 mm{sup 3} resolution, high-sensitivity PET camera dedicated to breast imaging. Methods: The PET camera under construction consists of 2304 units, each containing two 8 × 8 arrays of 1 mm{sup 3} LYSO crystals coupled to two position sensitive avalanche photodiodes (PSAPD). A subsection of the proposed camera with 512 PSAPDs has been constructed. The proposed thermal regulation design uses water-cooled heat sinks, thermoelectric elements, and thermistors to measure and regulate the temperature of the PSAPDs in a novel manner. Active cooling elements, placed at the edge of the detector stack due to limited access, are controlled based on collective leakage current and temperature measurements in order to keep all the PSAPDs at a consistent temperature. This thermal regulation design is characterized for the temperature profile across the camera and for the time required for cooling changes to propagate across the camera. These properties guide the implementation of a software-based, cascaded proportional-integral-derivative control loop that controls the current through the Peltier elements by monitoring thermistor temperature and leakage current. The stability of leakage current, temperature within the system using this control loop is tested over a period of 14 h. The energy resolution is then measured over a period of 8.66 h. Finally, the consistency of PSAPD gain between independent

  5. Validation of the GATE Monte Carlo simulation platform for modelling a CsI(Tl) scintillation camera dedicated to small-animal imaging

    International Nuclear Information System (INIS)

    Lazaro, D; Buvat, I; Loudos, G; Strul, D; Santin, G; Giokaris, N; Donnarieix, D; Maigne, L; Spanoudaki, V; Styliaris, S; Staelens, S; Breton, V

    2004-01-01

    Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT4 application for tomographic emission) is a new Monte Carlo simulation platform based on GEANT4 dedicated to nuclear imaging applications. This paper describes the GATE simulation of a prototype of scintillation camera dedicated to small-animal imaging and consisting of a CsI(Tl) crystal array coupled to a position-sensitive photomultiplier tube. The relevance of GATE to model the camera prototype was assessed by comparing simulated 99m Tc point spread functions, energy spectra, sensitivities, scatter fractions and image of a capillary phantom with the corresponding experimental measurements. Results showed an excellent agreement between simulated and experimental data: experimental spatial resolutions were predicted with an error less than 100 μm. The difference between experimental and simulated system sensitivities for different source-to-collimator distances was within 2%. Simulated and experimental scatter fractions in a [98-82 keV] energy window differed by less than 2% for sources located in water. Simulated and experimental energy spectra agreed very well between 40 and 180 keV. These results demonstrate the ability and flexibility of GATE for simulating original detector designs. The main weakness of GATE concerns the long computation time it requires: this issue is currently under investigation by the GEANT4 and the GATE collaborations

  6. Development of a liquid xenon Compton telescope dedicated to functional medical imaging; Etude et developpement d'un telescope compton au xenon liquide dedie a l'imagerie medicale fonctionnelle

    Energy Technology Data Exchange (ETDEWEB)

    Grignon, C

    2007-12-15

    Functional imaging is a technique used to locate in three dimensions the position of a radiotracer previously injected in a patient. The two main modalities used for a clinical application to detect tumors, the SPECT and the PET, use solid scintillators as a detection medium. The objective of this thesis was to investigate the possibility of using liquid xenon in order to benefit from the intrinsic properties of this medium in functional imaging. The feasibility study of such a device has been performed by taking into account the technical difficulties specific to the liquid xenon. First of all, simulations of a liquid xenon PET has been performed using Monte-Carlo methods. The results obtained with a large liquid xenon volume are promising : we can expect a reduction of the injected activity of radiotracer, an improvement of the spatial resolution of the image and a parallax free camera. The second part of the thesis was focused on the development of a new concept of medical imaging, the three gamma imaging, based on the use of a new emitter: the 44 scandium. Associated to a classical PET camera, the Compton telescope is used to infer the incoming direction of the third gamma ray by triangulation. Therefore, it is possible to reconstruct the position of each emitter in three dimensions. This work convinced the scientific community to support the construction and characterization of a liquid xenon Compton telescope. The first camera dedicated to small animal imaging should then be operational in 2009. (author)

  7. Thoracic staging in lung cancer: prospective comparison of 18F-FDG PET/MR imaging and 18F-FDG PET/CT.

    Science.gov (United States)

    Heusch, Philipp; Buchbender, Christian; Köhler, Jens; Nensa, Felix; Gauler, Thomas; Gomez, Benedikt; Reis, Henning; Stamatis, Georgios; Kühl, Hilmar; Hartung, Verena; Heusner, Till A

    2014-03-01

    Therapeutic decisions in non-small cell lung cancer (NSCLC) patients depend on the tumor stage. PET/CT with (18)F-FDG is widely accepted as the diagnostic standard of care. The purpose of this study was to compare a dedicated pulmonary (18)F-FDG PET/MR imaging protocol with (18)F-FDG PET/CT for primary and locoregional lymph node staging in NSCLC patients using histopathology as the reference. Twenty-two patients (12 men, 10 women; mean age ± SD, 65.1 ± 9.1 y) with histopathologically confirmed NSCLC underwent (18)F-FDG PET/CT, followed by (18)F-FDG PET/MR imaging, including a dedicated pulmonary MR imaging protocol. T and N staging according to the seventh edition of the American Joint Committee on Cancer staging manual was performed by 2 readers in separate sessions for (18)F-FDG PET/CT and PET/MR imaging, respectively. Results from histopathology were used as the standard of reference. The mean and maximum standardized uptake value (SUV(mean) and SUV(max), respectively) and maximum diameter of the primary tumor was measured and compared in (18)F-FDG PET/CT and PET/MR imaging. PET/MR imaging and (18)F-FDG PET/CT agreed on T stages in 16 of 16 of patients (100%). All patients were correctly staged by (18)F-FDG PET/CT and PET/MR (100%), compared with histopathology. There was no statistically significant difference between (18)F-FDG PET/CT and (18)F-FDG PET/MR imaging for lymph node metastases detection (P = 0.48). For definition of thoracic N stages, PET/MR imaging and (18)F-FDG PET/CT were concordant in 20 of 22 patients (91%). PET/MR imaging determined the N stage correctly in 20 of 22 patients (91%). (18)F-FDG PET/CT determined the N stage correctly in 18 of 22 patients (82%). The mean differences for SUV(mean) and SUV(max) of NSCLC in (18)F-FDG PET/MR imaging and (18)F-FDG PET/CT were 0.21 and -5.06. These differences were not statistically significant (P > 0.05). The SUV(mean) and SUV(max) measurements derived from (18)F-FDG PET/CT and (18)F-FDG PET

  8. Sub-millimetre DOI detector based on monolithic LYSO and digital SiPM for a dedicated small-animal PET system

    International Nuclear Information System (INIS)

    Marcinkowski, Radosław; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan

    2016-01-01

    The mouse model is widely used in a vast range of biomedical and preclinical studies. Thanks to the ability to detect and quantify biological processes at the molecular level in vivo, PET has become a well-established tool in these investigations. However, the need to visualize and quantify radiopharmaceuticals in anatomic structures of millimetre or less requires good spatial resolution and sensitivity from small-animal PET imaging systems. In previous work we have presented a proof-of-concept of a dedicated high-resolution small-animal PET scanner based on thin monolithic scintillator crystals and Digital Photon Counter photosensor. The combination of thin monolithic crystals and MLE positioning algorithm resulted in an excellent spatial resolution of 0.7 mm uniform in the entire field of view (FOV). However, the limitation of the scanner was its low sensitivity due to small thickness of the lutetium-yttrium oxyorthosilicate (LYSO) crystals (2 mm). Here we present an improved detector design for a small-animal PET system that simultaneously achieves higher sensitivity and sustains a sub-millimetre spatial resolution. The proposed detector consists of a 5 mm thick monolithic LYSO crystal optically coupled to a Digital Photon Counter. Mean nearest neighbour (MNN) positioning combined with depth of interaction (DOI) decoding was employed to achieve sub-millimetre spatial resolution. To evaluate detector performance the intrinsic spatial resolution, energy resolution and coincidence resolving time (CRT) were measured. The average intrinsic spatial resolution of the detector was 0.60 mm full-width-at-half-maximum (FWHM). A DOI resolution of 1.66 mm was achieved. The energy resolution was 23% FWHM at 511 keV and CRT of 529 ps were measured. The improved detector design overcomes the sensitivity limitation of the previous design by increasing the nominal sensitivity of the detector block and retains an excellent intrinsic spatial resolution. (paper)

  9. 'PET -Compton' system. Comparative evaluation with PET system using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Diaz Garcia, Angelina; Arista Romeu, Eduardo; Abreu Alfonso, Yamiel; Leyva Fabelo, Antonio; Pinnera Hernandez, Ibrahin; Bolannos Perez, Lourdes; Rubio Rodriguez, Juan A; Perez Morales, Jose M.; Arce Dubois, Pedro; Vela Morales, Oscar; Willmott Zappacosta, Carlos

    2011-01-01

    Positron Emission Tomography (PET) in small animals has actually achieved spatial resolution round about 1 mm and currently there are under study different approaches to improve this spatial resolution. One of them combines PET technology with Compton Cameras. This paper presents the idea of the so called 'PET-Compton' systems and includes comparative evaluation of spatial resolution and global efficiency in both PET and PET-Compton system by means of Monte Carlo simulations using Geant4 code. Simulation is done on a PET-Compton system consisting of LYSO-LuYAP scintillating detectors of particular small animal PET scanner named 'Clear-PET' and for Compton detectors based on CdZnTe semiconductor. A group of radionuclides that emits a positron (e + ) and γ quantum almost simultaneously and fulfills some selection criteria for their possible use in PET-Compton systems for medical and biological applications were studied under simulation conditions. (Author)

  10. MO-AB-206-01: PET Physics

    Energy Technology Data Exchange (ETDEWEB)

    Turkington, T. [Duke University Medical Center (United States)

    2016-06-15

    This education session will cover the physics and operation principles of gamma cameras and PET scanners. The first talk will focus on PET imaging. An overview of the principles of PET imaging will be provided, including positron decay physics, and the transition from 2D to 3D imaging. More recent advances in hardware and software will be discussed, such as time-of-flight imaging, and improvements in reconstruction algorithms that provide for options such as depth-of-interaction corrections. Quantitative applications of PET will be discussed, as well as the requirements for doing accurate quantitation. Relevant performance tests will also be described. Learning Objectives: Be able to describe basic physics principles of PET and operation of PET scanners. Learn about recent advances in PET scanner hardware technology. Be able to describe advances in reconstruction techniques and improvements Be able to list relevant performance tests. The second talk will focus on gamma cameras. The Nuclear Medicine subcommittee has charged a task group (TG177) to develop a report on the current state of physics testing of gamma cameras, SPECT, and SPECT/CT systems. The report makes recommendations for performance tests to be done for routine quality assurance, annual physics testing, and acceptance tests, and identifies those needed satisfy the ACR accreditation program and The Joint Commission imaging standards. The report is also intended to be used as a manual with detailed instructions on how to perform tests under widely varying conditions. Learning Objectives: At the end of the presentation members of the audience will: Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of gamma cameras for planar imaging. Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of SPECT systems. Be familiar with the tests of a SPECT/CT system that include the CT images

  11. MO-AB-206-01: PET Physics

    International Nuclear Information System (INIS)

    Turkington, T.

    2016-01-01

    This education session will cover the physics and operation principles of gamma cameras and PET scanners. The first talk will focus on PET imaging. An overview of the principles of PET imaging will be provided, including positron decay physics, and the transition from 2D to 3D imaging. More recent advances in hardware and software will be discussed, such as time-of-flight imaging, and improvements in reconstruction algorithms that provide for options such as depth-of-interaction corrections. Quantitative applications of PET will be discussed, as well as the requirements for doing accurate quantitation. Relevant performance tests will also be described. Learning Objectives: Be able to describe basic physics principles of PET and operation of PET scanners. Learn about recent advances in PET scanner hardware technology. Be able to describe advances in reconstruction techniques and improvements Be able to list relevant performance tests. The second talk will focus on gamma cameras. The Nuclear Medicine subcommittee has charged a task group (TG177) to develop a report on the current state of physics testing of gamma cameras, SPECT, and SPECT/CT systems. The report makes recommendations for performance tests to be done for routine quality assurance, annual physics testing, and acceptance tests, and identifies those needed satisfy the ACR accreditation program and The Joint Commission imaging standards. The report is also intended to be used as a manual with detailed instructions on how to perform tests under widely varying conditions. Learning Objectives: At the end of the presentation members of the audience will: Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of gamma cameras for planar imaging. Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of SPECT systems. Be familiar with the tests of a SPECT/CT system that include the CT images

  12. Incremental clinical value of a dedicated RT planning FDG PET-CT over staging PET-CT in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Lin, P.; Som, S.; Vinod, S.; Lin, M.; Shon, I. H.

    2009-01-01

    Full text:Objectives: To evaluate whether FDG-PET performed for radiotherapy planning can detect disease progression, compared with staging PET. Methods: Thirteen patients underwent a planning PET-CT for curative RT ( R T-PET ) within eight weeks of a staging PET-CT for newly diagnosed NSCLC between 10/2007 and 1/2009. All studies were acquired on a Philips GXL PET-CT using the same protocols, except RT-PET is acquired on a RT flat bed. The images were interpreted by consensus readings of two physicians: location/number, visual grading (0-4:3> liver, 4>brain), max transverse diameter ( M ax D ) (tumour margin is delineated by a SUV threshold of 2.5) and max SUV of each lesion. Progressive disease (PD) is defined as >10% increase in max D. Results: RT-PET detected PD (primary or nodal) or new metastases in 8 pts (61%) (mean interval:30.2±14 days, range:7-54 days). For primary tumour, RT-PET detected PD in 5

  13. Assessing the role of {sup 18}F-FDG PET and {sup 18}F-FDG PET/CT in the diagnosis of soft tissue musculoskeletal malignancies: a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Etchebehere, Elba C. [The University of Texas MD Anderson Cancer Center, Department of Nuclear Medicine, Houston, TX (United States); Sirio Libanes Hospital, Department of Nuclear Medicine, Sao Paulo (Brazil); Hobbs, Brian P.; Milton, Denai R. [The University of Texas MD Anderson Cancer Center, Department of Biostatistics, Houston, TX (United States); Malawi, Osama [The University of Texas MD Anderson Cancer Center, Department of Imaging Physics, Houston, TX (United States); Patel, Shreyaskumar; Benjamin, Robert S. [The University of Texas MD Anderson Cancer Center, Department of Sarcoma Medical Oncology, Houston, TX (United States); Macapinlac, Homer A. [The University of Texas MD Anderson Cancer Center, Department of Nuclear Medicine, Houston, TX (United States)

    2016-05-15

    Twelve years ago a meta-analysis evaluated the diagnostic performance of {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in assessing musculoskeletal soft tissue lesions (MsSTL). Currently, PET/CT has substituted PET imaging; however, there has not been any published meta-analysis on the use of PET/CT or a comparison of PET/CT with PET in the diagnosis of MsSTL. Therefore, we conducted a meta-analysis to identify the current diagnostic performance of {sup 18}F-FDG PET/CT and determine if there is added value when compared to PET. A systematic review of English articles was conducted, and MEDLINE PubMed, the Cochrane Library, and Embase were searched from 1996 to March 2015. Studies exploring the diagnostic accuracy of {sup 18}F-FDG PET/CT (or dedicated PET) compared to histopathology in patients with MsSTL undergoing investigation for malignancy were included. Our meta-analysis included 14 articles composed of 755 patients with 757 soft tissue lesions. There were 451 (60 %) malignant tumors and 306 benign lesions. The {sup 18}F-FDG PET/CT (and dedicated PET) mean sensitivity, specificity, accuracy, positive predictive value, and negative predictive value for diagnosing MsSTL were 0.96 (0.90, 1.00), 0.77 (0.67, 0.86), 0.88 (0.85, 0.91), 0.86 (0.78, 0.94), and 0.91 (0.83, 0.99), respectively. The posterior mean (95 % highest posterior density interval) for the AUC was 0.92 (0.88, 0.96). PET/CT had higher specificity, accuracy, and positive predictive value when compared to a dedicated PET (0.85, 0.89, and 0.91 vs 0.71, 0.85, and 0.82, respectively). {sup 18}F-FDG PET/CT and dedicated PET are both highly accurate in the diagnosis of MsSTL. PET/CT is more accurate and specific and has a higher positive predictive value than PET. (orig.)

  14. First PET scans in Estonia

    International Nuclear Information System (INIS)

    Nazarenko, Sergei

    2003-01-01

    First PET scans in Estonia were performed on 25th November 2002 in North Estonia Regional Hospital, Tallinn. Six patients with melanoma underwent scanning with FDG. This event was a result of thorough extensive preparations first started in 2000 during the European Association of Nuclear Medicine congress in Paris. During the congress first contacts were made with providers of mobile PET units. At the same time negotiations were begun with potential FDG suppliers. For the introduction of PET in Estonia mobile truckmounted scanning technology was chosen due to low level of initial investments. Of particular importance was also availability of maintenance personnel from the device providers. A significant prerequisite was potential availability of FDG from the neighbourhood - Finland and Sweden. The latter avoided the necessity for investments into local cyclotrons and local FDG production. For the first scanning experience the dedicated truckmounted PET-camera Accel, Siemens was brought by the International Hospital Group (IHG, Amersfoort, Netherlands). The device arrived by ferry from Stockholm to Tallinn harbour at 10 o'clock in the morning and left by ferry for Helsinki at 23 o'clock. The team-on-truck consisted of one technician for device operation, two drivers and two company representatives. North Estonia Regional Hospital provided three additional technicians for patient preparation and FDG injection, one nuclear medicine doctor and one specialist of biomedical engineering and medical physics. The FDG was provided by MAP Medical Technologies, Schering, Helsinki, Finland. The shipments were made by air. This was possible due to small distance between Tallinn and Helsinki of approximately 80 km due to the regular flight connections between the two cities. The FDG was shipped in two lots with a time interval of 4 hours. The patient selection was based on clinical and histopathology data. In all six patients the exam was justified for detailied staging and

  15. Development of a liquid xenon Compton telescope dedicated to functional medical imaging; Etude et developpement d'un telescope compton au xenon liquide dedie a l'imagerie medicale fonctionnelle

    Energy Technology Data Exchange (ETDEWEB)

    Grignon, C

    2007-12-15

    Functional imaging is a technique used to locate in three dimensions the position of a radiotracer previously injected in a patient. The two main modalities used for a clinical application to detect tumors, the SPECT and the PET, use solid scintillators as a detection medium. The objective of this thesis was to investigate the possibility of using liquid xenon in order to benefit from the intrinsic properties of this medium in functional imaging. The feasibility study of such a device has been performed by taking into account the technical difficulties specific to the liquid xenon. First of all, simulations of a liquid xenon PET has been performed using Monte-Carlo methods. The results obtained with a large liquid xenon volume are promising : we can expect a reduction of the injected activity of radiotracer, an improvement of the spatial resolution of the image and a parallax free camera. The second part of the thesis was focused on the development of a new concept of medical imaging, the three gamma imaging, based on the use of a new emitter: the 44 scandium. Associated to a classical PET camera, the Compton telescope is used to infer the incoming direction of the third gamma ray by triangulation. Therefore, it is possible to reconstruct the position of each emitter in three dimensions. This work convinced the scientific community to support the construction and characterization of a liquid xenon Compton telescope. The first camera dedicated to small animal imaging should then be operational in 2009. (author)

  16. Scanner calibration of a small animal PET camera based on continuous LSO crystals and flat panel PSPMTs

    International Nuclear Information System (INIS)

    Benlloch, J.M.; Carrilero, V.; Gonzalez, A.J.; Catret, J.; Lerche, Ch.W.; Abellan, D.; Garcia de Quiros, F.; Gimenez, M.; Modia, J.; Sanchez, F.; Pavon, N.; Ros, A.; Martinez, J.; Sebastia, A.

    2007-01-01

    We have constructed a small animal PET with four identical detector modules, each consisting of a continuous LYSO crystal attached to a Position Sensitive Photomultiplier Tube (PSPMT). The dimensions of the continuous crystal are 50x50 mm 2 and 10 mm thickness. The modules are separated 11 cm between each other in the scanner. In this paper we discuss the method used for the calibration of the camera for this special system with continuous detectors. We also present the preliminary values for the main performance parameters such as spatial and energy resolution, and sensitivity of the system

  17. PET/MR Imaging in Gynecologic Oncology.

    Science.gov (United States)

    Ohliger, Michael A; Hope, Thomas A; Chapman, Jocelyn S; Chen, Lee-May; Behr, Spencer C; Poder, Liina

    2017-08-01

    MR imaging and PET using 2-Deoxy-2-[ 18 F]fluoroglucose (FDG) are both useful in the evaluation of gynecologic malignancies. MR imaging is superior for local staging of disease whereas fludeoxyglucose FDG PET is superior for detecting distant metastases. Integrated PET/MR imaging scanners have great promise for gynecologic malignancies by combining the advantages of each modality into a single scan. This article reviews the technology behind PET/MR imaging acquisitions and technical challenges relevant to imaging the pelvis. A dedicated PET/MR imaging protocol; the roles of PET and MR imaging in cervical, endometrial, and ovarian cancers; and future directions for PET/MR imaging are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. A PET imaging system dedicated to mammography

    CERN Document Server

    Varela, J

    2007-01-01

    The imaging system Clear-PEM for positron emission mammography, under development within the framework of the Crystal Clear Collaboration at CERN, is presented. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes (APD) and readout by a fast low-noise electronic system. A dedicated digital trigger and data acquisition system is used for on-line selection of coincidence events with high efficiency, large bandwidth and negligible dead-time. The detector module performance was characterized in detail.

  19. Gamma camera image acquisition, display, and processing with the personal microcomputer

    International Nuclear Information System (INIS)

    Lear, J.L.; Pratt, J.P.; Roberts, D.R.; Johnson, T.; Feyerabend, A.

    1990-01-01

    The authors evaluated the potential of a microcomputer for direct acquisition, display, and processing of gamma camera images. Boards for analog-to-digital conversion and image zooming were designed, constructed, and interfaced to the Macintosh II (Apple Computer, Cupertino, Calif). Software was written for processing of single, gated, and time series images. The system was connected to gamma cameras, and its performance was compared with that of dedicated nuclear medicine computers. Data could be acquired from gamma cameras at rates exceeding 200,000 counts per second, with spatial resolution exceeding intrinsic camera resolution. Clinical analysis could be rapidly performed. This system performed better than most dedicated nuclear medicine computers with respect to speed of data acquisition and spatial resolution of images while maintaining full compatibility with the standard image display, hard-copy, and networking formats. It could replace such dedicated systems in the near future as software is refined

  20. Combined PET/MRI

    DEFF Research Database (Denmark)

    Bailey, D. L.; Pichler, B. J.; Gückel, B.

    2015-01-01

    This paper summarises key themes and discussions from the 4th international workshop dedicated to the advancement of the technical, scientific and clinical applications of combined positron emission tomography (PET)/magnetic resonance imaging (MRI) systems that was held in Tübingen, Germany, from...

  1. 18F-FDG imaging with a coincidence dual-headed gamma camera (Co-PET) in the diagnosis, staging and management of lung cancer

    International Nuclear Information System (INIS)

    Lin, P.; Chu, J.; Pocock, N.; Quach, T.; Sorensen, B.

    1999-01-01

    Full text: FDG-PET has an established role in the management of lung cancer, while the experience with FDG-Co-PET is limited. Our study aims to demonstrate the feasibility of Co-PET in staging and management of lung cancer. Thirty-nine Co-PET studies were performed on our first 36 patients (pts) with primary lung cancer between November 1997 and October 1998. Tomography of brain and torso with an ADAC Solus MCD gamma camera was performed (60 min after 200 MBq of 18 FFDG and > 6 h fasting). Histology subgroups included squamous (14 pts), small cell (1), adeno-carcinoma (11), broncho-alveolar (1), large cell (8), carcinoid (1). CT/clinical staging subgroups included 18 pts in stage 1, 4 in stage 2, 7 in stage 3a, 2 in stage 3b, 8 in stage 4. Compared with CT/clinical staging, FDG upstaged 5 pts (14%) with regional nodal metastases (mets) and 8 pts (22%) with distant mets (cervical = 2, lung = 1, brain = 3, bone = 3, abdomen = 4). FDG under-staged 2 pts in 3 sites (all < 15 mm). Surgical nodal staging was performed in 14 pts: false-positives occurred in 3 CT and 1 Co-PET studies, and false-negatives in one CT/Co-PET. Site sensitivities for primary (smallest 7 mm) and regional lymph nodes are 100% and 88% respectively. Specificities for primary and regional nodes are 100% and 96% respectively. Co-PET also has impact on management: treatment intent (6 pts), radiotherapy fields (1), diagnosis of lung mets (2) and radiation pneumonitis (1). In conclusion, our initial data demonstrate FDG-Co-PET scanning could provide a valuable addition to conventional imaging studies in diagnosis, staging and management of lung cancer

  2. ClearPEM: prototype PET device dedicated to breast imaging

    CERN Multimedia

    Joao Varela

    2009-01-01

    Clinical trials have begun in Portugal on a new breast imaging system (ClearPEM) using positron emission tomography (PET). The system, developed by a Portuguese consortium in collaboration with CERN and laboratories participating in the Crystal Clear collaboration, will detect even the smallest tumours and thus help avoid unnecessary biopsies.

  3. CyberPET: a PET service distributed over a wide area

    International Nuclear Information System (INIS)

    Pilloy, W.J.; Hellwig, D.; Schaeffer, A.; Hoffmann, P.; Lens, V.

    2002-01-01

    Aim: Demonstration of bi-directional PET data transmission, interactive display and co-registration, for the purpose of correlative imaging, treatment planning and teaching. Material and Method: In the year 2000, the initial problem to attend was to provide an effective PET service to a hospital (in Luxemburg) which lies 150 km away from a PET center (in another country). Once this solved, the procedure was expanded (in 2001) to co-registration with CT/MRI scans performed locally, and with radiotherapy simulation CT performed in another center 25 km away (in 2002). Equipment from various vendors was used (Siemens, Adac, GE, Hermes). With preliminary agreement of the national medical aid, patients are sent from the Nuclear Medicine Dept of the Centre Hospitalier in Luxemburg (CHL) to the Dept NM of the Saarland University Medical Center for PET examination. The digital data are then sent from the Siemens PET camera to a PC connected to the LAN, and then to a FTP server (Healthnet). The data are similarly collected by a PC of the hospital network in Luxemburg, and transferred to a Hermes NM station. The Dicom PET data are converted on the fly to Interfile, displayed interactively as any other tomographic data, printed and available on the NM image server. Since 2001, the PET data are co-registered with whole-body CT data recorded at CHL according to a specific protocol (see other paper of this group). Now in 2002, we are busy implementing the co-registration of PET data and simulation CT data obtained from the Centre Baclesse (CFB, 25 km from CHL) for the treatment planning of brain tumours (input into an ADAC system). Furthermore, we plan to send the data (after deletion of their digital ID) to a (South African) university which does not yet dispose of a PET camera, to allow the training of their registrars. Results: For the end-user clinician at CHL and CFB , the PET data have the quality of 'live data', which can be examined interactively, along with other imaging

  4. Dual-Modality PET/Ultrasound imaging of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Jennifer S.; Moses, William W.; Pouliot, Jean; Hsu, I.C.

    2005-11-11

    Functional imaging with positron emission tomography (PET)will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor ''aggressiveness''. However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should help provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate.Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems.

  5. Dual-Modality PET/Ultrasound imaging of the Prostate

    International Nuclear Information System (INIS)

    Huber, Jennifer S.; Moses, William W.; Pouliot, Jean; Hsu, I.C.

    2005-01-01

    Functional imaging with positron emission tomography (PET)will detect malignant tumors in the prostate and/or prostate bed, as well as possibly help determine tumor ''aggressiveness''. However, the relative uptake in a prostate tumor can be so great that few other anatomical landmarks are visible in a PET image. Ultrasound imaging with a transrectal probe provides anatomical detail in the prostate region that can be co-registered with the sensitive functional information from the PET imaging. Imaging the prostate with both PET and transrectal ultrasound (TRUS) will help determine the location of any cancer within the prostate region. This dual-modality imaging should help provide better detection and treatment of prostate cancer. LBNL has built a high performance positron emission tomograph optimized to image the prostate.Compared to a standard whole-body PET camera, our prostate-optimized PET camera has the same sensitivity and resolution, less backgrounds and lower cost. We plan to develop the hardware and software tools needed for a validated dual PET/TRUS prostate imaging system. We also plan to develop dual prostate imaging with PET and external transabdominal ultrasound, in case the TRUS system is too uncomfortable for some patients. We present the design and intended clinical uses for these dual imaging systems

  6. 68Ga-PSMA and 11C-Choline comparison using a tri-modality PET/CT-MRI (3.0 T) system with a dedicated shuttle.

    Science.gov (United States)

    Alonso, Omar; Dos Santos, Gerardo; García Fontes, Margarita; Balter, Henia; Engler, Henry

    2018-01-01

    The aim of this study was to prospectively compare the detection rate of 68 Ga-PSMA versus 11 C-Choline in men with prostate cancer with biochemical recurrence and to demonstrate the added value of a tri-modality PET/CT-MRI system. We analysed 36 patients who underwent both 11 C-Choline PET/CT and 68 Ga-PSMA PET/CT scanning within a time window of 1-2 weeks. Additionally, for the 68 Ga-PSMA scan, we used a PET/CT-MRI (3.0 T) system with a dedicated shuttle, acquiring MRI images of the pelvis. Both scans were positive in 18 patients (50%) and negative in 8 patients (22%). Nine patients were positive with 68 Ga-PSMA alone (25%) and one with 11 C-Choline only (3%). The median detected lesion per patient was 2 for 68 Ga-PSMA (range 0-93) and 1 for 11 C-Choline (range 0-57). Tumour to background ratios in all concordant lesions ( n  = 96) were higher for 68 Ga-PSMA than for 11 C-Choline (110.3 ± 107.8 and 27.5 ± 17.1, mean ± S.D., for each tracer, respectively P  = 0.0001). The number of detected lesions per patient was higher for 11 C-Choline in those with PSA ≥ 3.3 ng/mL, while the number of detected lesions was independent of PSA levels for 68 Ga-PSMA using the same PSA cut-off value. Metastatic pelvic lesions were found in 25 patients (69%) with 68 Ga-PSMA PET/CT, in 18 (50%) with 11 C-Choline PET/CT and in 21 (58%) with MRI (3.0 T). MRI was very useful in detecting recurrence in cases classified as indeterminate by means of PET/CT alone at prostate bed. In patients with prostate cancer with biochemical recurrence 68 Ga-PSMA detected more lesions per patient than 11 C-Choline, regardless of PSA levels. PET/CT-MRI (3.0 T) system is a feasible imaging modality that potentially adds useful relevant information with increased accuracy of diagnosis.

  7. Evaluation of pulmonary nodules: comparison of a prototype dual crystal (LSO/NAI) dual head coincidence camera and full ring positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Joshi, U.; Raijmakers, P.G.H.M.; Lingen, A. van; Comans, E.F.I.; Pijpers, R.; Teule, G.J.J.; Hoekstra, O.S.

    2005-01-01

    Purpose: To determine the concordance of a prototype dual head coincidence camera (LSO-PS) and full ring PET (BGO-PET) using 18 F-fluorodeoxyglucose (FDG) in the evaluation of pulmonary nodules (PNs). Materials and methods: Patients referred for evaluation of ≤3 PNs (≤3 cm diameter) were prospectively studied on the same day with both BGO-PET and LSO-PS. Imaging was performed at 60 and 120 min after injection of 370 MBq FDG, respectively. Images were independently interpreted by four observers with each observer blinded to the other modality for the same patient. Lesions were scored in terms of relative intensity versus background. Non-attenuation corrected (nonAC) BGO-PET was used as the reference test. Results: Forty-seven patients with 54 PNs (mean diameter 1.7 cm, S.D. 0.7) were included. Twelve nodules were in the ≤1.0 cm - 27 in the 1.1-2.0 cm - and 15 in the 2.1-3.0 cm range. Interobserver agreement was similar for both FDG imaging modalities. Using a sensitive assessment strategy with LSO-PS (≥ faint intensity deemed positive), there was a 97% (38/39, 95%CI 87-100%) concordance with BGO-PET and one false positive case with LSO-PS. Conservative reading (moderate or intense intensity deemed positive) resulted in a 92% (36/39, 95%CI 80-97%) concordance with BGO-PET, without false positives. The only lesion missed by LSO-PS using both assessment strategies involved a nodule 1.5 cm diameter that demonstrated moderate increased FDG uptake on BGO-PET. Conclusion: Depending on the test positivity criteria, LSO-PS demonstrates a high concordance (92-97%) with nonAC BGO-PET for the characterization of pulmonary nodules

  8. PET-COMPTON System. Comparative evaluation with PET System using Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Diaz Garcia, Angelina; Arista Romeu, Eduardo; Abreu Alfonso, Yamiel; Leyva Fabelo, Antonio; Pinnera HernAndez, Ibrahin; Bolannos Perez, Lourdes; Rubio Rodriguez, Juan A.; Perez Morales, Jose M.; Arce Dubois, Pedro; Vela Morales, Oscar; Willmott Zappacosta, Carlos

    2012-01-01

    Positron Emission Tomography (PET) in small animals has actually achieved spatial resolution round about 1 mm and currently there are under study different approaches to improve this spatial resolution. One of them combines PET technology with Compton Cameras. This paper presents the idea of the so called PET-Compton systems and has included comparative evaluation of spatial resolution and global efficiency in both PET and PET-Compton system by means of Monte Carlo simulations using Geant4 code. Simulation was done on a PET-Compton system made-up of LYSO-LuYAP scintillating detectors of particular small animal PET scanner named Clear-PET and for Compton detectors based on CdZnTe semiconductor. A group of radionuclides that emits a positron (e+) and quantum almost simultaneously and fulfills some selection criteria for their possible use in PET-Compton systems for medical and biological applications were studied under simulation conditions. By means of analytical reconstruction using SSRB (Single Slide Rebinning) method were obtained superior spatial resolution in PET-Compton system for all tested radionuclides (reaching sub-millimeter values of for 22Na source). However this analysis done by simulation have shown limited global efficiency values in PET-Compton system (in the order of 10 -5 -10 -6 %) instead of values around 5*10 -1 % that have been achieved in PET system. (author)

  9. A new methodological approach for PET implementation in radiotherapy treatment planning.

    Science.gov (United States)

    Bellan, Elena; Ferretti, Alice; Capirci, Carlo; Grassetto, Gaia; Gava, Marcello; Chondrogiannis, Sotirios; Virdis, Graziella; Marzola, Maria Cristina; Massaro, Arianna; Rubello, Domenico; Nibale, Otello

    2012-05-01

    In this paper, a new methodological approach to using PET information in radiotherapy treatment planning has been discussed. Computed tomography (CT) represents the primary modality to plan personalized radiation treatment, because it provides the basic electron density map for correct dose calculation. If PET scanning is also performed it is typically coregistered with the CT study. This operation can be executed automatically by a hybrid PET/CT scanner or, if the PET and CT imaging sets have been acquired through different equipment, by a dedicated module of the radiotherapy treatment planning system. Both approaches have some disadvantages: in the first case, the bore of a PET/CT system generally used in clinical practice often does not allow the use of certain bulky devices for patient immobilization in radiotherapy, whereas in the second case the result could be affected by limitations in window/level visualization of two different image modalities, and the displayed PET volumes can appear not to be related to the actual uptake into the patient. To overcome these problems, at our centre a specific procedure has been studied and tested in 30 patients, allowing good results of precision in the target contouring to be obtained. The process consists of segmentation of the biological target volume by a dedicated PET/CT console and its export to a dedicated radiotherapy system, where an image registration between the CT images acquired by the PET/CT scanner and a large-bore CT is performed. The planning target volume is contoured only on the large-bore CT and is used for virtual simulation, to individuate permanent skin markers on the patient.

  10. Thermal regulation for APDs in a 1 mm3 resolution clinical PET camera: design, simulation and experimental verification

    International Nuclear Information System (INIS)

    Zhai, Jinjian; Vandenbroucke, Arne; Levin, Craig S

    2014-01-01

    We are developing a 1 mm 3 resolution positron emission tomography camera dedicated to breast imaging. The camera collects high energy photons emitted from radioactively labeled agents introduced in the patients in order to detect molecular signatures of breast cancer. The camera comprises many layers of lutetium yttrium oxyorthosilicate (LYSO) scintillation crystals coupled to position sensitive avalanche photodiodes (PSAPDs). The main objectives of the studies presented in this paper are to investigate the temperature profile of the layers of LYSO–PSAPD detectors (a.k.a. ‘fins’) residing in the camera and to use these results to present the design of the thermal regulation system for the front end of the camera. The study was performed using both experimental methods and simulation. We investigated a design with a heat-dissipating fin. Three fin configurations are tested: fin with Al windows (FwW), fin without Al windows (FwoW) and fin with alumina windows (FwAW). A Fluent® simulation was conducted to study the experimentally inaccessible temperature of the PSAPDs. For the best configuration (FwW), the temperature difference from the center to a point near the edge is 1.0 K when 1.5 A current was applied to the Peltier elements. Those of FwoW and FwAW are 2.6 K and 1.7 K, respectively. We conclude that the design of a heat-dissipating fin configuration with ‘aluminum windows’ (FwW) that borders the scintillation crystal arrays of 16 adjacent detector modules has better heat dissipation capabilities than the design without ‘aluminum windows' (FwoW) and the design with ‘alumina windows’ (FwAW), respectively. (paper)

  11. Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Paulus, Daniel H.; Thorwath, Daniela; Schmidt, Holger; Quick, Harald H.

    2014-01-01

    Purpose: Multimodality imaging has become an important adjunct of state-of-the-art radiation therapy (RT) treatment planning. Recently, simultaneous PET/MR hybrid imaging has become clinically available and may also contribute to target volume delineation and biological individualization in RT planning. For integration of PET/MR hybrid imaging into RT treatment planning, compatible dedicated RT devices are required for accurate patient positioning. In this study, prototype RT positioning devices intended for PET/MR hybrid imaging are introduced and tested toward PET/MR compatibility and image quality. Methods: A prototype flat RT table overlay and two radiofrequency (RF) coil holders that each fix one flexible body matrix RF coil for RT head/neck imaging have been evaluated within this study. MR image quality with the RT head setup was compared to the actual PET/MR setup with a dedicated head RF coil. PET photon attenuation and CT-based attenuation correction (AC) of the hardware components has been quantitatively evaluated by phantom scans. Clinical application of the new RT setup in PET/MR imaging was evaluated in anin vivo study. Results: The RT table overlay and RF coil holders are fully PET/MR compatible. MR phantom and volunteer imaging with the RT head setup revealed high image quality, comparable to images acquired with the dedicated PET/MR head RF coil, albeit with 25% reduced SNR. Repositioning accuracy of the RF coil holders was below 1 mm. PET photon attenuation of the RT table overlay was calculated to be 3.8% and 13.8% for the RF coil holders. With CT-based AC of the devices, the underestimation error was reduced to 0.6% and 0.8%, respectively. Comparable results were found within the patient study. Conclusions: The newly designed RT devices for hybrid PET/MR imaging are PET and MR compatible. The mechanically rigid design and the reproducible positioning allow for straightforward CT-based AC. The systematic evaluation within this study provides the

  12. Clinical utility of 18-FDG-PET with a modified SPECT-camera using molecular coincidence detection in oncology

    International Nuclear Information System (INIS)

    Gabriel, M. F.

    1998-09-01

    Malignant diseases are belonging to one of the most frequent reasons for mortality and morbidity of people in industrialized countries. In order to avoid inadequate therapy such as unnecessary operations etc. accurate diagnostic techniques are needed to assess malignancy of proven lesions, for staging of cancer or to assess success of therapy. Many studies have reported the value of PET in such cases. Because of limited financial resources we started PET with a Dual-head-SPECT-camera modified with a MCD-module in February 1997 in order to obtain quick access to clinical 18-FDG studies. The aim of this work was to compare the results of our system with reports of the so called 'state of the art'-PET and with other diagnostic techniques used in clinical oncology. So far 124 studies were performed with the MCD-mode using a standardized investigation protocol between February 1997 and May 1998. The applied dose of 18-FDG for oncological studies was about 185 MBq. The tracer was supplied from the radio-pharmaceutical unit of the Department of Nuclear Medicine, Klinikum Rechts der Isar, Technische Universitaet Muenchen. The obtained results were carefully compared with CT, MRI and conventional radiology. In addition, the final diagnosis (based on histology, surgical reports, autopsy and follow up) was also considered. Oncological studies were done either to assess malignancy in certain lesions (n = 25), for staging cancer (n = 77), or to assess success of therapy (n = 22). Sensitivity and specificity for all oncological cases were 99 % and 89 % respectively. One false negative scan was a pretreated CNS-lymphoma, where false positive studies were due to inflammation. (author)

  13. MO-AB-206-02: Testing Gamma Cameras Based On TG177 WG Report

    Energy Technology Data Exchange (ETDEWEB)

    Halama, J. [Loyola Univ. Medical Center (United States)

    2016-06-15

    This education session will cover the physics and operation principles of gamma cameras and PET scanners. The first talk will focus on PET imaging. An overview of the principles of PET imaging will be provided, including positron decay physics, and the transition from 2D to 3D imaging. More recent advances in hardware and software will be discussed, such as time-of-flight imaging, and improvements in reconstruction algorithms that provide for options such as depth-of-interaction corrections. Quantitative applications of PET will be discussed, as well as the requirements for doing accurate quantitation. Relevant performance tests will also be described. Learning Objectives: Be able to describe basic physics principles of PET and operation of PET scanners. Learn about recent advances in PET scanner hardware technology. Be able to describe advances in reconstruction techniques and improvements Be able to list relevant performance tests. The second talk will focus on gamma cameras. The Nuclear Medicine subcommittee has charged a task group (TG177) to develop a report on the current state of physics testing of gamma cameras, SPECT, and SPECT/CT systems. The report makes recommendations for performance tests to be done for routine quality assurance, annual physics testing, and acceptance tests, and identifies those needed satisfy the ACR accreditation program and The Joint Commission imaging standards. The report is also intended to be used as a manual with detailed instructions on how to perform tests under widely varying conditions. Learning Objectives: At the end of the presentation members of the audience will: Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of gamma cameras for planar imaging. Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of SPECT systems. Be familiar with the tests of a SPECT/CT system that include the CT images

  14. MO-AB-206-02: Testing Gamma Cameras Based On TG177 WG Report

    International Nuclear Information System (INIS)

    Halama, J.

    2016-01-01

    This education session will cover the physics and operation principles of gamma cameras and PET scanners. The first talk will focus on PET imaging. An overview of the principles of PET imaging will be provided, including positron decay physics, and the transition from 2D to 3D imaging. More recent advances in hardware and software will be discussed, such as time-of-flight imaging, and improvements in reconstruction algorithms that provide for options such as depth-of-interaction corrections. Quantitative applications of PET will be discussed, as well as the requirements for doing accurate quantitation. Relevant performance tests will also be described. Learning Objectives: Be able to describe basic physics principles of PET and operation of PET scanners. Learn about recent advances in PET scanner hardware technology. Be able to describe advances in reconstruction techniques and improvements Be able to list relevant performance tests. The second talk will focus on gamma cameras. The Nuclear Medicine subcommittee has charged a task group (TG177) to develop a report on the current state of physics testing of gamma cameras, SPECT, and SPECT/CT systems. The report makes recommendations for performance tests to be done for routine quality assurance, annual physics testing, and acceptance tests, and identifies those needed satisfy the ACR accreditation program and The Joint Commission imaging standards. The report is also intended to be used as a manual with detailed instructions on how to perform tests under widely varying conditions. Learning Objectives: At the end of the presentation members of the audience will: Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of gamma cameras for planar imaging. Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of SPECT systems. Be familiar with the tests of a SPECT/CT system that include the CT images

  15. Modeling and analysis of all the positron emitters simulation steps generated during the treatment phase in proton-therapy - from the beam to the PET camera - for the follow-up of the irradiations

    International Nuclear Information System (INIS)

    Ty, C.V.N.

    2012-01-01

    Carlo modeling of the proton range using the GEANT4 software (versions 9.2 and 9.4) relying and using cross-sections; 3) A simulation of the PET acquisition using a simplified modeling and a Monte Carlo modeling. Our results show that a simplified modeling of the beam does not affect the estimation of the proton range. Besides, the Monte Carlo modeling of the PET camera enables modeling the noise present in the PET signal measured in a homogeneous area. Preliminary results of the PET camera modeling are presented in a head model (inhomogeneous). Finally, a simplified modeling of the PET camera enables evaluate the proton range in a homogeneous area with a 1 mm-precision, which is equivalent to the reproducibility of the PET offline measure as described in (Knopf et al., 2008). (author) [fr

  16. Small animal PET: aspects of performance assessment

    International Nuclear Information System (INIS)

    Weber, Simone; Bauer, Andreas

    2004-01-01

    Dedicated small animal positron emission tomography (PET) systems are increasingly prevalent in industry (e.g. for preclinical drug development) and biological research. Such systems permit researchers to perform animal studies of a longitudinal design characterised by repeated measurements in single animals. With the advent of commercial systems, scanners have become readily available and increasingly popular. As a consequence, technical specifications are becoming more diverse, making scanner systems less broadly applicable. The investigator has, therefore, to make a decision regarding which type of scanner is most suitable for the intended experiments. This decision should be based on gantry characteristics and the physical performance. The first few steps have been taken towards standardisation of the assessment of performance characteristics of dedicated animal PET systems, though such assessment is not yet routinely implemented. In this review, we describe current methods of evaluation of physical performance parameters of small animal PET scanners. Effects of methodologically different approaches on the results are assessed. It is underscored that particular attention has to be paid to spatial resolution, sensitivity, scatter fraction and count rate performance. Differences in performance measurement methods are described with regard to commercially available systems, namely the Concorde MicroPET systems P4 and R4 and the quad-HIDAC. Lastly, consequences of differences in scanner performance parameters are rated with respect to applications of small animal PET. (orig.)

  17. Usefulness of FDG-PET in the evaluation of patients with colon and rectal cancer in a PET center in Chile

    Energy Technology Data Exchange (ETDEWEB)

    Jofre, M J; Massardo, L T; Canessa, J; Sierralta, P; Gonzalez, P [Molecular Imaging PET Center, Nuclear Medicine Department, Military Hospital, Santiago (Chile)

    2007-11-15

    Introduction: FDG, PET is a useful imaging technique in the management of patients with gastrointestinal tumours, mainly in oesophageal and colorectal cancer. In Chile, colorectal cancer is a prevalent disease, representing the 7th cause of death in men and 6th in women. The aim of the study was to assess FDG-PET value in the management of colorectal cancer in the first PET center in Chile. Material and Methods: Population: In a retrospective analysis, we studied 130 patients with 159 PET scans, 56% corresponded to women. Group A rectal cancer: 42 patients (55 studies), mean age 61 {+-} 11 y.o. (range 39-80) Group B colon cancer: 88 patients (104 studies), mean age 61 {+-} 11 y.o. (range 39-80). Referral: In the whole population, 53% were studied by recurrence suspicion (31% with increased CEA levels with negative anatomical imaging), 33% for re-staging, 8% for therapy control and 6% for staging. Eighty-five % was submitted to surgery (range: lm -7y) and 42% presented local or distance dissemination; 70% have received chemotherapy and 23% associated radiotherapy. Technique: Whole-body images were acquired with a dedicated high resolution PET Siemens Ecat Exact HR+ camera 60 minutes after injection of intravenous F18-FDG, produced at the Chilean Nuclear Energy Commission (mean dose: 12 mCi). Visual analysis and semi-quantitative standardized uptake value (SUV) were performed by a consensus of 5 nuclear medicine physicians. Results: 65% of the PET studies were positive, showing hypermetabolic tumoral uptake (63% studies in colon cancer and 69% in rectal cancer). In 30% from the positive cases liver lesions were found, 52% of them without other lesions. In 75% from positive studies there was extrahepatic involvement. In the group B, local recurrence was found in 37%. In 48% cases there was good correlation between anatomical images available and FDG and in 42% new unknown lesions were found with PET. CEA levels: they were available in 62% of the cases (71% of them

  18. [Indications and instructions to patients for a positron emission tomography-PET scan. The importance of the hybridic PET/CT-computerised tomography scan and which specialty should be responsible for its function].

    Science.gov (United States)

    Grammaticos, Philip; Datseris, Ioannis; Gerali, Sofia; Papantoniou, Vassilios; Valsamaki, Pipitsa; Boundas, Dimitrios

    2007-01-01

    Indications and instructions to patients for performing a positron emission tomography - PET scan are mentioned. Although PET camera was developed in 1970 its clinical indications were established in about 1998. The hybridic PET/CT- computerized tomography scanner appeared in 2001 and its clinical indications are still under discussion. These discussions refer to both the use of PET/CT as an acquisition correction and anatomic localization device for PET images (AC/A) and to its use as a diagnostic CT scan (dCT). Most of the patients submitted for a PET scan have already done a dCT scan. This was the case in 286 out of the first 300 patients referred to "Evangelismos" hospital in Athens for a PET scan. These two scans can be matched electronically. Extra cost, space, personnel and radiation absorption dose especially in children, are additional factors to be considered in using the PET/CT scanner. The specialty of Nuclear Medicine is now based on the PET camera, its best part and main equipment for molecular imaging. It is very much easier and faster for a Nuclear Medicine physician who routinely reports tomographic PET and SPET images, to be familiar with the CT images than for a Radiologist to get to "know how" about the PET camera and the whole Nuclear Medicine Department. Nuclear Medicine is about open radiation sources, molecular imaging, specific radio-pharmacology, radiobiology, radiation protection etc, while on the other hand in some countries, Nuclear Physicians have already spent, as part of their official training, six months in a Radiology Department whose function is considered to be at least 25% about the CT scanner. We come to the conclusion that the PET/CT scanner should be under the responsibility of the Nuclear Medicine Department and the Radiologist should act as an advisor.

  19. single photon emission tomography and positron emission tomography - Part 1 (October 2012), Part 2 (October 2010)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2010-10-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) and the positron emission tomography (PET) imaging techniques. Part 1 Content: 1 - Introduction: anatomic, functional and molecular imaging; 2 - Radiotracers: chemical and physical constraints, gamma photon emitters, positon emitters, radioisotopes production, emitters type and imaging techniques; 3 - Gamma cameras; 4 - Quantification in emission tomography: attenuation, scattering, un-stationary spatial resolution; 5 - Synthesis and conclusion. Part 2 content: 1 - Positon emitters; 2 - Positons detection: Coincidence detection (electronic collimation, PET detectors with gamma cameras, dedicated PET detectors, spectrometry); PET detectors type; time-of-flight PET; 2D PET; 3D PET; 3 - Quantification in emission tomography: detected events, attenuation, scattering, fortuitous coincidences, standardisation; 4 - Common SPECT and PET problems: partial volume effect, movement, tomographic reconstruction, calibration, dead time; 5 - Synthesis and conclusion

  20. Neutron cameras for ITER

    International Nuclear Information System (INIS)

    Johnson, L.C.; Barnes, C.W.; Batistoni, P.

    1998-01-01

    Neutron cameras with horizontal and vertical views have been designed for ITER, based on systems used on JET and TFTR. The cameras consist of fan-shaped arrays of collimated flight tubes, with suitably chosen detectors situated outside the biological shield. The sight lines view the ITER plasma through slots in the shield blanket and penetrate the vacuum vessel, cryostat, and biological shield through stainless steel windows. This paper analyzes the expected performance of several neutron camera arrangements for ITER. In addition to the reference designs, the authors examine proposed compact cameras, in which neutron fluxes are inferred from 16 N decay gammas in dedicated flowing water loops, and conventional cameras with fewer sight lines and more limited fields of view than in the reference designs. It is shown that the spatial sampling provided by the reference designs is sufficient to satisfy target measurement requirements and that some reduction in field of view may be permissible. The accuracy of measurements with 16 N-based compact cameras is not yet established, and they fail to satisfy requirements for parameter range and time resolution by large margins

  1. Dynamic imaging with coincidence gamma camera

    International Nuclear Information System (INIS)

    Elhmassi, Ahmed

    2008-01-01

    In this paper we develop a technique to calculate dynamic parameters from data acquired using gamma-camera PET (gc PET). Our method is based on an algorithm development for dynamic SPECT, which processes all decency projection data simultaneously instead of reconstructing a series of static images individually. The algorithm was modified to account for the extra data that is obtained with gc PET (compared with SPEC). The method was tested using simulated projection data for both a SPECT and a gc PET geometry. These studies showed the ability of the code to reconstruct simulated data with a varying range of half-lives. The accuracy of the algorithm was measured in terms of the reconstructed half-life and initial activity for the simulated object. The reconstruction of gc PET data showed improvement in half-life and activity compared to SPECT data of 23% and 20%, respectively (at 50 iterations). The gc PET algorithm was also tested using data from an experimental phantom and finally, applied to a clinical dataset, where the algorithm was further modified to deal with the situation where the activity in certain pixels decreases and then increases during the acquisition. (author)

  2. Japanese guideline for the oncology FDG-PET/CT data acquisition protocol. Synopsis of Version 2.0

    International Nuclear Information System (INIS)

    Fukukita, Hiroyoshi; Suzuki, Kazufumi; Matsumoto, Keiichi; Terauchi, Takashi; Shimada, Naoki; Daisaki, Hiromitsu; Ikari, Yasuhiko; Senda, Michio

    2014-01-01

    This synopsis outlines the Japanese guideline Version 2.0 for the data acquisition protocol of oncology FDG-PET/CT scans that was created by a joint task force of the Japanese Society of Nuclear Medicine Technology, the Japanese Society of Nuclear Medicine and the Japanese Council of PET Imaging, and was published in Kakuigaku-Gijutsu 2013; 33:377-420 in Japanese. The guideline aims at standardizing the PET image quality among PET centers and different PET camera models by providing criteria for the IEC body phantom image quality as well as for the patient PET image quality based on the noise equivalent count (NEC), NEC density and liver signal-to-noise ratio, so that the appropriate scanning parameters can be determined for each PET camera. This Version 2.0 covers issues that were not focused on in Version 1.0, including the accuracy of the standardized uptake value (SUV), effect of body size together with adjustment of scanning duration, and time-of-flight (TOF) reconstruction technique. Version 2.0 also presents data acquired with new PET camera models that were not tested in Version 1.0. Reference values for physical indicators of phantom image quality have been updated as well. (author)

  3. Robust real-time extraction of respiratory signals from PET list-mode data.

    Science.gov (United States)

    Salomon, Andre; Zhang, Bin; Olivier, Patrick; Goedicke, Andreas

    2018-05-01

    Respiratory motion, which typically cannot simply be suspended during PET image acquisition, affects lesions' detection and quantitative accuracy inside or in close vicinity to the lungs. Some motion compensation techniques address this issue via pre-sorting ("binning") of the acquired PET data into a set of temporal gates, where each gate is assumed to be minimally affected by respiratory motion. Tracking respiratory motion is typically realized using dedicated hardware (e.g. using respiratory belts and digital cameras). Extracting respiratory signalsdirectly from the acquired PET data simplifies the clinical workflow as it avoids to handle additional signal measurement equipment. We introduce a new data-driven method "Combined Local Motion Detection" (CLMD). It uses the Time-of-Flight (TOF) information provided by state-of-the-art PET scanners in order to enable real-time respiratory signal extraction without additional hardware resources. CLMD applies center-of-mass detection in overlapping regions based on simple back-positioned TOF event sets acquired in short time frames. Following a signal filtering and quality-based pre-selection step, the remaining extracted individual position information over time is then combined to generate a global respiratory signal. The method is evaluated using 7 measured FDG studies from single and multiple scan positions of the thorax region, and it is compared to other software-based methods regarding quantitative accuracy and statistical noise stability. Correlation coefficients around 90% between the reference and the extracted signal have been found for those PET scans where motion affected features such as tumors or hot regions were present in the PET field-of-view. For PET scans with a quarter of typically applied radiotracer doses, the CLMD method still provides similar high correlation coefficients which indicates its robustness to noise. Each CLMD processing needed less than 0.4s in total on a standard multi-core CPU

  4. Robust real-time extraction of respiratory signals from PET list-mode data

    Science.gov (United States)

    Salomon, André; Zhang, Bin; Olivier, Patrick; Goedicke, Andreas

    2018-06-01

    Respiratory motion, which typically cannot simply be suspended during PET image acquisition, affects lesions’ detection and quantitative accuracy inside or in close vicinity to the lungs. Some motion compensation techniques address this issue via pre-sorting (‘binning’) of the acquired PET data into a set of temporal gates, where each gate is assumed to be minimally affected by respiratory motion. Tracking respiratory motion is typically realized using dedicated hardware (e.g. using respiratory belts and digital cameras). Extracting respiratory signals directly from the acquired PET data simplifies the clinical workflow as it avoids handling additional signal measurement equipment. We introduce a new data-driven method ‘combined local motion detection’ (CLMD). It uses the time-of-flight (TOF) information provided by state-of-the-art PET scanners in order to enable real-time respiratory signal extraction without additional hardware resources. CLMD applies center-of-mass detection in overlapping regions based on simple back-positioned TOF event sets acquired in short time frames. Following a signal filtering and quality-based pre-selection step, the remaining extracted individual position information over time is then combined to generate a global respiratory signal. The method is evaluated using seven measured FDG studies from single and multiple scan positions of the thorax region, and it is compared to other software-based methods regarding quantitative accuracy and statistical noise stability. Correlation coefficients around 90% between the reference and the extracted signal have been found for those PET scans where motion affected features such as tumors or hot regions were present in the PET field-of-view. For PET scans with a quarter of typically applied radiotracer doses, the CLMD method still provides similar high correlation coefficients which indicates its robustness to noise. Each CLMD processing needed less than 0.4 s in total on a standard

  5. Monte Carlo modeling of a clinical PET scanner by using the GATE dedicated computer code

    International Nuclear Information System (INIS)

    Vieira, Igor Fagner; Lima, Fernando Roberto de Andrade

    2011-01-01

    This paper demonstrates more possible detailed the GATE simulated architecture involved in the 4D modeling of a General Electric PET scanner, the Advance. So, it were used data present in the literature on the configuration of GE modelled PET. The obtained results which were the 3D components of PET creation, and the simulation of 4D phenomena as the source decay and the gantry whirl, exhibit the potential of tool in emission tomograph modelling

  6. GePEToS: A Geant4 Monte Carlo simulation package for positron emission tomography

    International Nuclear Information System (INIS)

    Jan, Sebastien; Collot, Johann; Gallin-Martel, Marie-Laure; Martin, Philippe; Mayet, Frederic; Tournefier, Edwige

    2003-01-01

    GePEToS is a simulation framework developed over the last few years for assessing the instrumental performance of future PET scanners. It is based on Geant4, written in Object- Oriented C++ and runs on Linux platforms. The validity of GePEToS has been tested on the well-known Siemens ECAT EXACT HR+ camera. The results of two application examples are presented: the design optimization of a liquid Xe μPET camera dedicated to small animal imaging as well as the evaluation of the effect of a strong axial magnetic field on the image resolution of a Concorde P4 μPET camera. Index Terms-Positron Emission Tomography, Monte Carlo Simulation, Geant 4. (authors)

  7. A Very High Spatial Resolution Detector for Small Animal PET

    International Nuclear Information System (INIS)

    Kanai Shah, M.S.

    2007-01-01

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated

  8. Development of a hardware-based registration system for the multimodal medical images by USB cameras

    International Nuclear Information System (INIS)

    Iwata, Michiaki; Minato, Kotaro; Watabe, Hiroshi; Koshino, Kazuhiro; Yamamoto, Akihide; Iida, Hidehiro

    2009-01-01

    There are several medical imaging scanners and each modality has different aspect for visualizing inside of human body. By combining these images, diagnostic accuracy could be improved, and therefore, several attempts for multimodal image registration have been implemented. One popular approach is to use hybrid image scanners such as positron emission tomography (PET)/CT and single photon emission computed tomography (SPECT)/CT. However, these hybrid scanners are expensive and not fully available. We developed multimodal image registration system with universal serial bus (USB) cameras, which is inexpensive and applicable to any combinations of existed conventional imaging scanners. The multiple USB cameras will determine the three dimensional positions of a patient while scanning. Using information of these positions and rigid body transformation, the acquired image is registered to the common coordinate which is shared with another scanner. For each scanner, reference marker is attached on gantry of the scanner. For observing the reference marker's position by the USB cameras, the location of the USB cameras can be arbitrary. In order to validate the system, we scanned a cardiac phantom with different positions by PET and MRI scanners. Using this system, images from PET and MRI were visually aligned, and good correlations between PET and MRI images were obtained after the registration. The results suggest this system can be inexpensively used for multimodal image registrations. (author)

  9. Development of a PET/Cerenkov-light hybrid imaging system

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Hamamura, Fuka; Kato, Katsuhiko; Ogata, Yoshimune; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Hatazawa, Jun; Watabe, Hiroshi

    2014-01-01

    Purpose: Cerenkov-light imaging is a new molecular imaging technology that detects visible photons from high-speed electrons using a high sensitivity optical camera. However, the merit of Cerenkov-light imaging remains unclear. If a PET/Cerenkov-light hybrid imaging system were developed, the merit of Cerenkov-light imaging would be clarified by directly comparing these two imaging modalities. Methods: The authors developed and tested a PET/Cerenkov-light hybrid imaging system that consists of a dual-head PET system, a reflection mirror located above the subject, and a high sensitivity charge coupled device (CCD) camera. The authors installed these systems inside a black box for imaging the Cerenkov-light. The dual-head PET system employed a 1.2 × 1.2 × 10 mm 3 GSO arranged in a 33 × 33 matrix that was optically coupled to a position sensitive photomultiplier tube to form a GSO block detector. The authors arranged two GSO block detectors 10 cm apart and positioned the subject between them. The Cerenkov-light above the subject is reflected by the mirror and changes its direction to the side of the PET system and is imaged by the high sensitivity CCD camera. Results: The dual-head PET system had a spatial resolution of ∼1.2 mm FWHM and sensitivity of ∼0.31% at the center of the FOV. The Cerenkov-light imaging system's spatial resolution was ∼275μm for a 22 Na point source. Using the combined PET/Cerenkov-light hybrid imaging system, the authors successfully obtained fused images from simultaneously acquired images. The image distributions are sometimes different due to the light transmission and absorption in the body of the subject in the Cerenkov-light images. In simultaneous imaging of rat, the authors found that 18 F-FDG accumulation was observed mainly in the Harderian gland on the PET image, while the distribution of Cerenkov-light was observed in the eyes. Conclusions: The authors conclude that their developed PET/Cerenkov-light hybrid imaging

  10. ECAT ART - a continuously rotating PET camera: performance characteristics, initial clinical studies, and installation considerations in a nuclear medicine department

    International Nuclear Information System (INIS)

    Bailey, D.L.; Young, H.; Bloomfield, P.M.; Meikle, S.R.; Glass, D.; Myers, M.J.; Spinks, T.J.; Watson, C.C.; Luk, P.; Peters, A.M.; Jones, T.

    1997-01-01

    Advances in image reconstruction techniques have permitted the development of a commercial, rotating, partial ring, fully 3D scanner, the ECAT ART. The system has less than one-half the number of bismuth germanate detectors compared with a full ring scanner with the equivalent field of view, resulting in reduced capital cost. The performance characteristics, implications for installation in a nuclear medicine department, and clinical utility of the scanner are presented in this report. The sensitivity (20 cm diameter x 20 cm long cylindrical phantom, no scatter correction) is 11400 cps.kBq -1 .ml -1 . This compares with 5800 and 40500 cps.kBq -1 .ml -1 in 2D and 3D respectively for the equivalent full ring scanner (ECAT EXACT). With an energy window of 350-650 keV the maximum noise equivalent count (NEC) rate was 27 kcps at a radioactivity concentration of ∝15 kBq .ml -1 in the cylinder. Spatial resolution is ∝6 mm full width at half maximum on axis degrading to just under 8 mm at a distance of 20 cm off axis. Installation and use within the nuclear medicine department does not appreciably increase background levels of radiation on gamma cameras in adjacent rooms and the dose rate to an operator in the same room is 2 μSv .h -1 for a typical fluorine-18 fluorodeoxyglucose ( 18 F-FDG) study with an initial injected activity of 370 MBq. The scanner has been used for clinical imaging with 18 F-FDG for neurological and oncological applications. Its novel use for imaging iron-52 transferrin for localising erythropoietic activity demonstrates its sensitivity and resolution advantages over a conventional dual-headed gamma camera. The ECAT ART provides a viable alternative to conventional full ring PET scanners without compromising the performance required for clinical PET imaging. (orig.). With 9 figs., 3 tabs

  11. PET-CT imaging fusion in the assessment of head and neck carcinoma

    International Nuclear Information System (INIS)

    Santos, Denise Takehana dos; Chojniak, Rubens; Lima, Eduardo Nobrega Pereira; Cavalcanti, Marcelo Gusmao Paraiso

    2006-01-01

    Objective: The authors have established a methodological approach to evaluate head and neck squamous cell carcinoma aiming at identifying and distinguishing high metabolic activity inside the lesion, combining in a single examination, functional, metabolic and morphological data simultaneously acquired by means of different non-dedicated positron emission tomography (PET)-computed tomography (CT) device. Materials and Methods: The study population included 17 patients with head and neck squamous cell carcinoma submitted to a non-dedicated 18 F-FDG-PET imaging at Department of Diagnostic Imaging of Hospital do Cancer, Sao Paulo, SP, Brazil. CT and 18 F-FDG-PET images were simultaneously acquired in a non-dedicated device. The original data were transferred to an independent workstation by means of the Entegra 2 NT software to generate PET-CT imaging fusion. Results: The findings were defined as positive in the presence of a well defined focal area of increased radiopharmaceutical uptake in regions not related with the normal biodistribution of the tracer. Conclusion: The fusion of simultaneously acquired images in a single examination ( 18 F-FDGPET and CT) has allowed the topographic-metabolic mapping of the lesion as well as the localization of high metabolic activity areas inside the tumor, indicating recidivation or metastasis and widening the array of alternatives for radiotherapy or surgical planning. (author)

  12. New findings on cerebral ammonia uptake in HE using functional (13)N-ammonia PET

    DEFF Research Database (Denmark)

    Sørensen, Michael; Keiding, Susanne

    2007-01-01

    PET is a functional imaging technique suitable for studies of brain ammonia metabolism. Dynamic (13)N-ammonia PET yields time-courses of radioactivity concentrations in brain (PET camera) and blood (samples). Ahl et al. (Hepatology 40:73-79, 2004) and Keiding et al. (Hepatology 43:42-50, 2006...

  13. A 16-channel MR coil for simultaneous PET/MR imaging in breast cancer

    International Nuclear Information System (INIS)

    Dregely, Isabel; Lanz, Titus; Mueller, Matthias F.; Metz, Stephan; Kuschan, Marika; Nimbalkar, Manoj; Ziegler, Sibylle I.; Nekolla, Stephan G.; Schwaiger, Markus; Bundschuh, Ralph A.; Haase, Axel

    2015-01-01

    To implement and evaluate a dedicated receiver array coil for simultaneous positron emission tomography/magnetic resonance (PET/MR) imaging in breast cancer. A 16-channel receiver coil design was optimized for simultaneous PET/MR imaging. To assess MR performance, the signal-to-noise ratio, parallel imaging capability and image quality was evaluated in phantoms, volunteers and patients and compared to clinical standard protocols. For PET evaluation, quantitative 18 F-FDG PET images of phantoms and seven patients (14 lesions) were compared to images without the coil. In PET image reconstruction, a CT-based template of the coil was combined with the MR-acquired attenuation correction (AC) map of the phantom/patient. MR image quality was comparable to clinical MR-only examinations. PET evaluation in phantoms showed regionally varying underestimation of the standardised uptake value (SUV; mean 22 %) due to attenuation caused by the coil. This was improved by implementing the CT-based coil template in the AC (<2 % SUV underestimation). Patient data indicated that including the coil in the AC increased the SUV values in the lesions (21 ± 9 %). Using a dedicated PET/MR breast coil, state-of-the-art MRI was possible. In PET, accurate quantification and image homogeneity could be achieved if a CT-template of this coil was included in the AC for PET image reconstruction. (orig.)

  14. An emerging indication of FDG-PET: pleural tumours

    International Nuclear Information System (INIS)

    Balogova, S.; Kerrou, K.; Montravers, F.; Grahek, D.; Aide, N.; Jacob, T.; Younsi, N.; Cailleux, N.; Talbot, J.N.

    2003-01-01

    The diagnosis and staging of malignant pleural tumours is difficult by means of radiology and also histology. Nevertheless an early diagnose, in particular in those people exposed to asbestos, and an accurate staging are key factors for a better survival. There is thus a potential role for FD G imaging in these relatively rare cancers. In our series, were are currently able to evaluate 22 FD G examinations performed in 16 patients referred for apparently isolated pleural lesions. Twelve FD G examinations were performed with a dedicated PET machine (C-PET, Adac) and ten with a coincidence detection gamma camera (Irix, Picker). The precise clinical settings were the following: characterisation of pleural masses or search for the unknown primary tumour in case of adenocarcinoma (6 cases), staging of a mesothelioma (5 cases), suspicion of recurrence and/or residual lesions (11 cases). The pleural lesions took-up FD G in all cases. By adding our results to data of the five previously published studies, the sensitivity for detecting malignant pleural lesions that are not yet characterised as primary pleural cancer is 99% and the specificity 79%. There was in our series one false positive result due to an inflammatory lesion. False negative results for the detection of lymph node invasion occurred in three patients and were in relation with an infra-centimetric size and the difficulty to distinguish, on FD G images, mediastinal lymph nodes from a widespread pleural and pulmonary extension of cancer. A change in patient management was induced by the FD G examination in 4 patients (25%) and the evolution confirmed that the choice was appropriate. Unknown lesions that could have modified the management were discovered in two other patients. This study highlights the fact that FD G imaging has an impact on the management of patients with solitary pleural lesions and can detect recurrences, in some cases even more accurately than invasive procedures with histology. From our

  15. Head and neck imaging with PET and PET/CT: artefacts from dental metallic implants

    International Nuclear Information System (INIS)

    Goerres, Gerhard W.; Hany, Thomas F.; Kamel, Ehab; Schulthess von, Gustav K.; Buck, Alfred

    2002-01-01

    Germanium-68 based attenuation correction (PET Ge68 ) is performed in positron emission tomography (PET) imaging for quantitative measurements. With the recent introduction of combined in-line PET/CT scanners, CT data can be used for attenuation correction. Since dental implants can cause artefacts in CT images, CT-based attenuation correction (PET CT ) may induce artefacts in PET images. The purpose of this study was to evaluate the influence of dental metallic artwork on the quality of PET images by comparing non-corrected images and images attenuation corrected by PET Ge68 and PET CT . Imaging was performed on a novel in-line PET/CT system using a 40-mAs scan for PET CT in 41 consecutive patients with high suspicion of malignant or inflammatory disease. In 17 patients, additional PET Ge68 images were acquired in the same imaging session. Visual analysis of fluorine-18 fluorodeoxyglucose (FDG) distribution in several regions of the head and neck was scored on a 4-point scale in comparison with normal grey matter of the brain in the corresponding PET images. In addition, artefacts adjacent to dental metallic artwork were evaluated. A significant difference in image quality scoring was found only for the lips and the tip of the nose, which appeared darker on non-corrected than on corrected PET images. In 33 patients, artefacts were seen on CT, and in 28 of these patients, artefacts were also seen on PET imaging. In eight patients without implants, artefacts were seen neither on CT nor on PET images. Direct comparison of PET Ge68 and PET CT images showed a different appearance of artefacts in 3 of 17 patients. Malignant lesions were equally well visible using both transmission correction methods. Dental implants, non-removable bridgework etc. can cause artefacts in attenuation-corrected images using either a conventional 68 Ge transmission source or the CT scan obtained with a combined PET/CT camera. We recommend that the non-attenuation-corrected PET images also be

  16. PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation

    Energy Technology Data Exchange (ETDEWEB)

    Espana, S; Herraiz, J L; Vicente, E; Udias, J M [Grupo de Fisica Nuclear, Departmento de Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid, Madrid (Spain); Vaquero, J J; Desco, M [Unidad de Medicina y CirugIa Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain)], E-mail: jose@nuc2.fis.ucm.es

    2009-03-21

    Monte Carlo simulations play an important role in positron emission tomography (PET) imaging, as an essential tool for the research and development of new scanners and for advanced image reconstruction. PeneloPET, a PET-dedicated Monte Carlo tool, is presented and validated in this work. PeneloPET is based on PENELOPE, a Monte Carlo code for the simulation of the transport in matter of electrons, positrons and photons, with energies from a few hundred eV to 1 GeV. PENELOPE is robust, fast and very accurate, but it may be unfriendly to people not acquainted with the FORTRAN programming language. PeneloPET is an easy-to-use application which allows comprehensive simulations of PET systems within PENELOPE. Complex and realistic simulations can be set by modifying a few simple input text files. Different levels of output data are available for analysis, from sinogram and lines-of-response (LORs) histogramming to fully detailed list mode. These data can be further exploited with the preferred programming language, including ROOT. PeneloPET simulates PET systems based on crystal array blocks coupled to photodetectors and allows the user to define radioactive sources, detectors, shielding and other parts of the scanner. The acquisition chain is simulated in high level detail; for instance, the electronic processing can include pile-up rejection mechanisms and time stamping of events, if desired. This paper describes PeneloPET and shows the results of extensive validations and comparisons of simulations against real measurements from commercial acquisition systems. PeneloPET is being extensively employed to improve the image quality of commercial PET systems and for the development of new ones.

  17. PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation

    International Nuclear Information System (INIS)

    Espana, S; Herraiz, J L; Vicente, E; Udias, J M; Vaquero, J J; Desco, M

    2009-01-01

    Monte Carlo simulations play an important role in positron emission tomography (PET) imaging, as an essential tool for the research and development of new scanners and for advanced image reconstruction. PeneloPET, a PET-dedicated Monte Carlo tool, is presented and validated in this work. PeneloPET is based on PENELOPE, a Monte Carlo code for the simulation of the transport in matter of electrons, positrons and photons, with energies from a few hundred eV to 1 GeV. PENELOPE is robust, fast and very accurate, but it may be unfriendly to people not acquainted with the FORTRAN programming language. PeneloPET is an easy-to-use application which allows comprehensive simulations of PET systems within PENELOPE. Complex and realistic simulations can be set by modifying a few simple input text files. Different levels of output data are available for analysis, from sinogram and lines-of-response (LORs) histogramming to fully detailed list mode. These data can be further exploited with the preferred programming language, including ROOT. PeneloPET simulates PET systems based on crystal array blocks coupled to photodetectors and allows the user to define radioactive sources, detectors, shielding and other parts of the scanner. The acquisition chain is simulated in high level detail; for instance, the electronic processing can include pile-up rejection mechanisms and time stamping of events, if desired. This paper describes PeneloPET and shows the results of extensive validations and comparisons of simulations against real measurements from commercial acquisition systems. PeneloPET is being extensively employed to improve the image quality of commercial PET systems and for the development of new ones.

  18. FDG PET/CT findings in a clinically diagnosed case of childhood autism

    International Nuclear Information System (INIS)

    Manglunia, Ashmi S.; Puranik, Ameya D.

    2016-01-01

    Autism is a neurodevelopmental disorder with multifactorial etiology and varied presentation, in which early diagnosis is crucial to the implementation of early treatment. A 6-year-old child clinically diagnosed with autism, and a normal magnetic resonance imaging underwent dedicated 18F-fluorodeoxyglucose brain positron emission tomography (PET) as an ancillary investigation. PET image showed diffuse bilateral temporal hypometabolism. Although PET imaging is currently not indicated in the evaluation of autism, characteristic imaging patterns on PET can provide corroborative information and increase the diagnostic confidence for the same

  19. Monte Carlo simulations in small animal PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Branco, Susana [Universidade de Lisboa, Faculdade de Ciencias, Instituto de Biofisica e Engenharia Biomedica, Lisbon (Portugal)], E-mail: susana.silva@fc.ul.pt; Jan, Sebastien [Service Hospitalier Frederic Joliot, CEA/DSV/DRM, Orsay (France); Almeida, Pedro [Universidade de Lisboa, Faculdade de Ciencias, Instituto de Biofisica e Engenharia Biomedica, Lisbon (Portugal)

    2007-10-01

    This work is based on the use of an implemented Positron Emission Tomography (PET) simulation system dedicated for small animal PET imaging. Geant4 Application for Tomographic Emission (GATE), a Monte Carlo simulation platform based on the Geant4 libraries, is well suited for modeling the microPET FOCUS system and to implement realistic phantoms, such as the MOBY phantom, and data maps from real examinations. The use of a microPET FOCUS simulation model with GATE has been validated for spatial resolution, counting rates performances, imaging contrast recovery and quantitative analysis. Results from realistic studies of the mouse body using {sup -}F and [{sup 18}F]FDG imaging protocols are presented. These simulations include the injection of realistic doses into the animal and realistic time framing. The results have shown that it is possible to simulate small animal PET acquisitions under realistic conditions, and are expected to be useful to improve the quantitative analysis in PET mouse body studies.

  20. Implementation and application of simulation platform of PET based on GATE

    International Nuclear Information System (INIS)

    Zhang Bin; Zhao Shujun; Zhang Shixun; Liu Haojia

    2010-01-01

    Positron emission tomography (PET) is a tool for obtaining functional image in vivo and GATE is a dedicated software for PET/SPECT simulation based on Mentor Carlo Method. It encapsulates the Geant4 libraries to achieve a modular and provides a number of new characteristics. In practice, a simulation platform of PET has been builded employing GATE based on Ubuntu operating system, including many keys and skills in the process. We have exploited benchmark PET, a testing example in GATE, and implemented PET scanner simulation in the end. Through analyzing the simulation data, the result demonstrate that predictive goal has been reached. The work provides the foundation for investigating PET scanner and optimizing the algorithm of tomograph image reconstruction. (authors)

  1. PET and SPECT in neurology

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium). Dept. of Radiology and Nuclear Medicine; Vries, Erik F.J. de; Waarde, Aren van [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Otte, Andreas (ed.) [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology

    2014-07-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  2. PET and SPECT in neurology

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Ghent Univ.; Vries, Erik F.J. de; Waarde, Aren van; Otte, Andreas

    2014-01-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  3. “Calibration-on-the-spot”: How to calibrate an EMCCD camera from its images

    DEFF Research Database (Denmark)

    Mortensen, Kim; Flyvbjerg, Henrik

    2016-01-01

    In order to count photons with a camera, the camera must be calibrated. Photon counting is necessary, e.g., to determine the precision of localization-based super-resolution microscopy. Here we present a protocol that calibrates an EMCCD camera from information contained in isolated, diffraction-......-limited spots in any image taken by the camera, thus making dedicated calibration procedures redundant by enabling calibration post festum, from images filed without calibration information....

  4. PET and SPECT in psychiatry

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Otte, Andreas; Vries, Erik F.J. de; Waarde, Aren van

    2014-01-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  5. PET and SPECT in psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium); Otte, Andreas [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-09-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  6. Readout and characterisation of new silicon pixel photodiode array for use in PET

    International Nuclear Information System (INIS)

    Hooper, P.; Ward, G.; Lerch, R.; Rozenfeld, A.

    2002-01-01

    Full text: Positron emission tomography (PET) is a functional imaging tool, which is able to quantify physiological, and biochemical processes in vivo using short-lived cyclotron-produced radiotracers. The main physical principle of PET is the simultaneous measurement of two 511 keV photons which are emitted in opposite directions following the annihilation of a positron in tissue. The accuracy of tracking these photons determines the accuracy of localising the radiotracer in the body, which is referred to as the spatial resolution of the system. Compared with conventional single photon imaging with gamma cameras, PET provides superior spatial resolution and sensitivity. However, compared with anatomical imaging techniques, the spatial resolution remains relatively poor at approximately 4-6 mm full width at half maximum (FWHM), compared with 1 mm FWHM for MRI. The Centre for Medical Radiation Physics at the University of Wollongong is developing a new Positron Emission Tomography (PET) detection sub-module that will significantly improve the spatial resolution of PET. The new sub-module design is simple and robust to minimise module assembly complications and is completely independent of photomultiplier tubes. The new sub-module has also been designed to maximise its flexibility for easy sub-module coupling so as to form a complete, customised, detection module to be used in PET scanners dedicated to human brain and breast, and small animal studies. A new computer controlled gantry allows the system to be used for PET and SPECT applications. Silicon 8x8 detector arrays have been developed by CMRP and will be optically coupled scintillation crystals and readout using the VIKING tM hybrid preamplifier chip to form the basis of the new module Characterisation of the pixel photodiode array has been performed to check the uniformity of the response of the array. This characterisation has been done using a pulsed, near infra-red laser diode system and alpha particles

  7. Gate Simulation of a Gamma Camera

    International Nuclear Information System (INIS)

    Abidi, Sana; Mlaouhi, Zohra

    2008-01-01

    Medical imaging is a very important diagnostic because it allows for an exploration of the internal human body. The nuclear imaging is an imaging technique used in the nuclear medicine. It is to determine the distribution in the body of a radiotracers by detecting the radiation it emits using a detection device. Two methods are commonly used: Single Photon Emission Computed Tomography (SPECT) and the Positrons Emission Tomography (PET). In this work we are interested on modelling of a gamma camera. This simulation is based on Monte-Carlo language and in particular Gate simulator (Geant4 Application Tomographic Emission). We have simulated a clinical gamma camera called GAEDE (GKS-1) and then we validate these simulations by experiments. The purpose of this work is to monitor the performance of these gamma camera and the optimization of the detector performance and the the improvement of the images quality. (Author)

  8. PET/CT cardiology: an area whose boundaries are still out of sight

    Energy Technology Data Exchange (ETDEWEB)

    Lucignani, Giovanni [University of Milan and Unit of Molecular Imaging, Institute of Radiological Sciences, Division of Radiation Therapy, European Institute of Oncology, Milan (Italy)

    2006-05-15

    Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.

  9. Real-time vehicle matching for multi-camera tunnel surveillance

    Science.gov (United States)

    Jelača, Vedran; Niño Castañeda, Jorge Oswaldo; Frías-Velázquez, Andrés; Pižurica, Aleksandra; Philips, Wilfried

    2011-03-01

    Tracking multiple vehicles with multiple cameras is a challenging problem of great importance in tunnel surveillance. One of the main challenges is accurate vehicle matching across the cameras with non-overlapping fields of view. Since systems dedicated to this task can contain hundreds of cameras which observe dozens of vehicles each, for a real-time performance computational efficiency is essential. In this paper, we propose a low complexity, yet highly accurate method for vehicle matching using vehicle signatures composed of Radon transform like projection profiles of the vehicle image. The proposed signatures can be calculated by a simple scan-line algorithm, by the camera software itself and transmitted to the central server or to the other cameras in a smart camera environment. The amount of data is drastically reduced compared to the whole image, which relaxes the data link capacity requirements. Experiments on real vehicle images, extracted from video sequences recorded in a tunnel by two distant security cameras, validate our approach.

  10. ePix: a class of architectures for second generation LCLS cameras

    International Nuclear Information System (INIS)

    Dragone, A; Caragiulo, P; Markovic, B; Herbst, R; Reese, B; Herrmann, S C; Hart, P A; Segal, J; Carini, G A; Kenney, C J; Haller, G

    2014-01-01

    ePix is a novel class of ASIC architectures, based on a common platform, optimized to build modular scalable detectors for LCLS. The platform architecture is composed of a random access analog matrix of pixel with global shutter, fast parallel column readout, and dedicated sigma-delta analog-to-digital converters per column. It also implements a dedicated control interface and all the required support electronics to perform configuration, calibration and readout of the matrix. Based on this platform a class of front-end ASICs and several camera modules, meeting different requirements, can be developed by designing specific pixel architectures. This approach reduces development time and expands the possibility of integration of detector modules with different size, shape or functionality in the same camera. The ePix platform is currently under development together with the first two integrating pixel architectures: ePix100 dedicated to ultra low noise applications and ePix10k for high dynamic range applications.

  11. High-Speed Data Acquisition and Digital Signal Processing System for PET Imaging Techniques Applied to Mammography

    Science.gov (United States)

    Martinez, J. D.; Benlloch, J. M.; Cerda, J.; Lerche, Ch. W.; Pavon, N.; Sebastia, A.

    2004-06-01

    This paper is framed into the Positron Emission Mammography (PEM) project, whose aim is to develop an innovative gamma ray sensor for early breast cancer diagnosis. Currently, breast cancer is detected using low-energy X-ray screening. However, functional imaging techniques such as PET/FDG could be employed to detect breast cancer and track disease changes with greater sensitivity. Furthermore, a small and less expensive PET camera can be utilized minimizing main problems of whole body PET. To accomplish these objectives, we are developing a new gamma ray sensor based on a newly released photodetector. However, a dedicated PEM detector requires an adequate data acquisition (DAQ) and processing system. The characterization of gamma events needs a free-running analog-to-digital converter (ADC) with sampling rates of more than 50 Ms/s and must achieve event count rates up to 10 MHz. Moreover, comprehensive data processing must be carried out to obtain event parameters necessary for performing the image reconstruction. A new generation digital signal processor (DSP) has been used to comply with these requirements. This device enables us to manage the DAQ system at up to 80 Ms/s and to execute intensive calculi over the detector signals. This paper describes our designed DAQ and processing architecture whose main features are: very high-speed data conversion, multichannel synchronized acquisition with zero dead time, a digital triggering scheme, and high throughput of data with an extensive optimization of the signal processing algorithms.

  12. High-performance electronics for time-of-flight PET systems

    International Nuclear Information System (INIS)

    Choong, W-S; Peng, Q; Vu, C Q; Turko, B T; Moses, W W

    2013-01-01

    We have designed and built a high-performance readout electronics system for time-of-flight positron emission tomography (TOF PET) cameras. The electronics architecture is based on the electronics for a commercial whole-body PET camera (Siemens/CPS Cardinal electronics), modified to improve the timing performance. The fundamental contributions in the electronics that can limit the timing resolution include the constant fraction discriminator (CFD), which converts the analog electrical signal from the photo-detector to a digital signal whose leading edge is time-correlated with the input signal, and the time-to-digital converter (TDC), which provides a time stamp for the CFD output. Coincident events are identified by digitally comparing the values of the time stamps. In the Cardinal electronics, the front-end processing electronics are performed by an Analog subsection board, which has two application-specific integrated circuits (ASICs), each servicing a PET block detector module. The ASIC has a built-in CFD and TDC. We found that a significant degradation in the timing resolution comes from the ASIC's CFD and TDC. Therefore, we have designed and built an improved Analog subsection board that replaces the ASIC's CFD and TDC with a high-performance CFD (made with discrete components) and TDC (using the CERN high-performance TDC ASIC). The improved Analog subsection board is used in a custom single-ring LSO-based TOF PET camera. The electronics system achieves a timing resolution of 60 ps FWHM. Prototype TOF detector modules are read out with the electronics system and give coincidence timing resolutions of 259 ps FWHM and 156 ps FWHM for detector modules coupled to LSO and LaBr 3 crystals respectively.

  13. Multi Camera Multi Object Tracking using Block Search over Epipolar Geometry

    Directory of Open Access Journals (Sweden)

    Saman Sargolzaei

    2000-01-01

    Full Text Available We present strategy for multi-objects tracking in multi camera environment for the surveillance and security application where tracking multitude subjects are of utmost importance in a crowded scene. Our technique assumes partially overlapped multi-camera setup where cameras share common view from different angle to assess positions and activities of subjects under suspicion. To establish spatial correspondence between camera views we employ an epipolar geometry technique. We propose an overlapped block search method to find the interested pattern (target in new frames. Color pattern update scheme has been considered to further optimize the efficiency of the object tracking when object pattern changes due to object motion in the field of views of the cameras. Evaluation of our approach is presented with the results on PETS2007 dataset..

  14. Pharmacological studies of the lung with PET

    International Nuclear Information System (INIS)

    Syrota, A.

    1986-10-01

    Positron emission tomography (PET), known to be used for lung ventilation and perfusion studies, can also be used in pharmacology to obtain information that is otherwise not available. The lung takes up biologically active substances which can be inactivated or activated, and synthesises and releases others. Such information in man has been obtained from samples of human lungs, or from in vivo first-pass studies, invasive or not, as well as from in vivo kinetic studies using external detection methods with scintillation cameras. PET provides now quantitative regional data in the human lung

  15. Development of continuous detectors for a high resolution animal PET system

    International Nuclear Information System (INIS)

    Siegel, S.; Cherry, S.R.; Ricci, A.R.; Shao, Y.; Phelps, M.E.

    1995-01-01

    The authors propose a design for a high resolution, gamma-camera style detector that is suitable for use in a positron emission tomograph dedicated to small animal research. Through Monte Carlo simulation the authors modeled the performance of a detector composed of one 76.2 x 76.2 x 8 mm thick LSO crystal coupled to a 3 in. square position sensitive photomultiplier tube (PS-PMT). The authors investigated the effect of optical coupling compounds, surface treatment and dept of interaction on the quantity (efficiency) and distribution (spread) of scintillation photons reaching the photocathode. They also investigated linearization of the position response. The authors propose a PET system consisting of fourteen of these detectors in 2 rings, yielding a 16 cm diameter by 15 cm long tomograph. It would operate in 3-D mode subtending a 68% solid angle to the center. The expected spatial resolution is (≤2 mm), with a system efficiency of ∼ 10% at the center (200 keV lower threshold) and a singles count rate capability of approximately 10 6 cps per detector

  16. Development of compact DOI-measurable PET detectors for simultaneous PET/MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Yiping; Sun, Xishan [University of Texas MD Anderson Cancer Center (United States); Lou, Kai [Rice University (United States)

    2015-05-18

    It is critically needed yet challenging to develop compact PET detectors with high sensitivity and uniform, high imaging resolution for improving the performance of simultaneous PET/MR imaging, particularly for an integrated/inserted small-bore system. Using the latest “edge-less” SiPM arrays for DOI measurement using the design of dual-ended-scintillator readout, we developed several compact PET detectors suited for PET/MR imaging. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together along all sides to form a large detector panel. Detectors with 1.5x1.5 and 2.0x2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or capacitor-based signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables to dedicated ASIC frontend electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition positioned outside the MRI scanner for coincidence event selection. Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ~18% and 2.8 ns energy and timing resolutions, and around 2-3 mm DOI resolution. A large size detector panel can be scaled up with these modular detectors and different PET systems can be flexibly configured with the scalable readout electronics and data acquisition, providing an important design advantage for different system and application requirements. It is expected that standard shielding of detectors, electronics and signal transfer lines can be applied for simultaneous PET/MR imaging applications, with desired DOI measurement capability to enhance the PET performance and image quality.

  17. Development of compact DOI-measurable PET detectors for simultaneous PET/MR Imaging

    International Nuclear Information System (INIS)

    Shao, Yiping; Sun, Xishan; Lou, Kai

    2015-01-01

    It is critically needed yet challenging to develop compact PET detectors with high sensitivity and uniform, high imaging resolution for improving the performance of simultaneous PET/MR imaging, particularly for an integrated/inserted small-bore system. Using the latest “edge-less” SiPM arrays for DOI measurement using the design of dual-ended-scintillator readout, we developed several compact PET detectors suited for PET/MR imaging. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together along all sides to form a large detector panel. Detectors with 1.5x1.5 and 2.0x2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or capacitor-based signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables to dedicated ASIC frontend electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition positioned outside the MRI scanner for coincidence event selection. Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ~18% and 2.8 ns energy and timing resolutions, and around 2-3 mm DOI resolution. A large size detector panel can be scaled up with these modular detectors and different PET systems can be flexibly configured with the scalable readout electronics and data acquisition, providing an important design advantage for different system and application requirements. It is expected that standard shielding of detectors, electronics and signal transfer lines can be applied for simultaneous PET/MR imaging applications, with desired DOI measurement capability to enhance the PET performance and image quality.

  18. Simulation study comparing the helmet-chin PET with a cylindrical PET of the same number of detectors

    Science.gov (United States)

    Ahmed, Abdella M.; Tashima, Hideaki; Yoshida, Eiji; Nishikido, Fumihiko; Yamaya, Taiga

    2017-06-01

    There is a growing interest in developing brain PET scanners with high sensitivity and high spatial resolution for early diagnosis of neurodegenerative diseases and studies of brain functions. Sensitivity of the PET scanner can be improved by increasing the solid angle. However, conventional PET scanners are designed based on a cylindrical geometry, which may not be the most efficient design for brain imaging in terms of the balance between sensitivity and cost. We proposed a dedicated brain PET scanner based on a hemispheric shape detector and a chin detector (referred to as the helmet-chin PET), which is designed to maximize the solid angle by increasing the number of lines-of-response in the hemisphere. The parallax error, which PET scanners with a large solid angle tend to have, can be suppressed by the use of depth-of-interaction detectors. In this study, we carry out a realistic evaluation of the helmet-chin PET using Monte Carlo simulation based on the 4-layer GSO detector which consists of a 16  ×  16  ×  4 array of crystals with dimensions of 2.8  ×  2.8  ×  7.5 mm3. The purpose of this simulation is to show the gain in imaging performance of the helmet-chin PET compared with the cylindrical PET using the same number of detectors in each configuration. The sensitivity of the helmet-chin PET evaluated with a cylindrical phantom has a significant increase, especially at the top of the (field-of-view) FOV. The peak-NECR of the helmet-chin PET is 1.4 times higher compared to the cylindrical PET. The helmet-chin PET provides relatively low noise images throughout the FOV compared to the cylindrical PET which exhibits enhanced noise at the peripheral regions. The results show the helmet-chin PET can significantly improve the sensitivity and reduce the noise in the reconstructed images.

  19. Validation of GEANT3 simulation studies with a dual-head PMT ClearPET TM prototype

    CERN Document Server

    Ziemons, K; Streun, M; Pietrzyk, U

    2004-01-01

    The ClearPET TM project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2/sup nd/ generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET TM camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (...

  20. Preliminary Experience with Small Animal SPECT Imaging on Clinical Gamma Cameras

    Directory of Open Access Journals (Sweden)

    P. Aguiar

    2014-01-01

    Full Text Available The traditional lack of techniques suitable for in vivo imaging has induced a great interest in molecular imaging for preclinical research. Nevertheless, its use spreads slowly due to the difficulties in justifying the high cost of the current dedicated preclinical scanners. An alternative for lowering the costs is to repurpose old clinical gamma cameras to be used for preclinical imaging. In this paper we assess the performance of a portable device, that is, working coupled to a single-head clinical gamma camera, and we present our preliminary experience in several small animal applications. Our findings, based on phantom experiments and animal studies, provided an image quality, in terms of contrast-noise trade-off, comparable to dedicated preclinical pinhole-based scanners. We feel that our portable device offers an opportunity for recycling the widespread availability of clinical gamma cameras in nuclear medicine departments to be used in small animal SPECT imaging and we hope that it can contribute to spreading the use of preclinical imaging within institutions on tight budgets.

  1. Temporal lobe dysfunction in childhood autism: a PET study

    International Nuclear Information System (INIS)

    Boddaert, N.; Poline, J.B.; Brunelle, F.; Zilbovicius, M.; Boddaert, N.; Brunelle, F.; Chabane, N.; Barthelemy, C.; Zilbovicius, M.; Bourgeois, M.; Samson, Y.

    2002-01-01

    Childhood autism is a severe developmental disorder that impairs the acquisition of some of the most important skills in human life. Progress in understanding the neural basis of childhood autism requires clear and reliable data indicating specific neuro-anatomical or neuro-physiological abnormalities. The purpose of the present study was to research localized brain dysfunction in autistic children using functional brain imaging. Regional cerebral blood flow (rCBF) was measured with positron emission tomography (PET) in 21 primary autistic children and 10 age-matched non autistic children. A statistical parametric analysis of rCBF images revealed significant bilateral temporal hypoperfusion in the associative auditory cortex (superior temporal gyrus) and in the multimodal cortex (superior temporal sulcus) in the autistic group (p<0.001). In addition, temporal hypoperfusion was detected individually in 77% of autistic children. These findings provide robust evidence of well localized functional abnormalities in autistic children located in the superior temporal lobe. Such localized abnormalities were not detected with the low resolution PET camera (14-22). This study suggests that high resolution PET camera combined with statistical parametric mapping is useful to understand developmental disorders. (authors)

  2. Decreased occipital lobe metabolism by FDG-PET/CT

    Science.gov (United States)

    Solnes, Lilja; Nalluri, Abhinav; Cohen, Jesse; Jones, Krystyna M.; Zan, Elcin; Javadi, Mehrbod S.; Venkatesan, Arun

    2017-01-01

    Objective: To compare brain metabolism patterns on fluorodeoxyglucose (FDG)-PET/CT in anti–NMDA receptor and other definite autoimmune encephalitis (AE) and to assess how these patterns differ between anti–NMDA receptor neurologic disability groups. Methods: Retrospective review of clinical data and initial dedicated brain FDG-PET/CT studies for neurology inpatients with definite AE, per published consensus criteria, treated at a single academic medical center over a 10-year period. Z-score maps of FDG-PET/CT were made using 3-dimensional stereotactic surface projections in comparison to age group–matched controls. Brain region mean Z scores with magnitudes ≥2.00 were interpreted as significant. Comparisons were made between anti–NMDA receptor and other definite AE patients as well as among patients with anti–NMDA receptor based on modified Rankin Scale (mRS) scores at the time of FDG-PET/CT. Results: The medial occipital lobes were markedly hypometabolic in 6 of 8 patients with anti–NMDA receptor encephalitis and as a group (Z = −4.02, interquartile range [IQR] 2.14) relative to those with definite AE (Z = −2.32, 1.46; p = 0.004). Among patients with anti–NMDA receptor encephalitis, the lateral and medial occipital lobes were markedly hypometabolic for patients with mRS 4–5 (lateral occipital lobe Z = −3.69, IQR 1; medial occipital lobe Z = −4.08, 1) compared with those with mRS 0–3 (lateral occipital lobe Z = −0.83, 2; p occipital lobe Z = −1.07, 2; p = 0.001). Conclusions: Marked medial occipital lobe hypometabolism by dedicated brain FDG-PET/CT may serve as an early biomarker for discriminating anti–NMDA receptor encephalitis from other AE. Resolution of lateral and medial occipital hypometabolism may correlate with improved neurologic status in anti–NMDA receptor encephalitis. PMID:29159205

  3. Technology challenges in small animal PET imaging

    International Nuclear Information System (INIS)

    Lecomte, Roger

    2004-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging modality allowing biochemical processes to be investigated in vivo with sensitivity in the picomolar range. For this reason, PET has the potential to play a major role in the emerging field of molecular imaging by enabling the study of molecular pathways and genetic processes in living animals non-invasively. The challenge is to obtain a spatial resolution that is appropriate for rat and mouse imaging, the preferred animal models for research in biology, while achieving a sensitivity adequate for real-time measurement of rapid dynamic processes in vivo without violating tracer kinetic principles. An overview of the current state of development of dedicated small animal PET scanners is given, and selected applications are reported and discussed with respect to performance and significance to research in biology

  4. Development of baby cyclotron for PET in Korea

    International Nuclear Information System (INIS)

    Chai, J.S.; Kim, Y.S.; Hu, J.Y.; Shin, Y.C.; Yoon, M.H.

    2001-01-01

    Development of a 13 MeV cyclotron for Positron Emission Tomography (PET) has been in progress since April 1999 at the Korea Cancer Center Hospital (KCCH). The study has been carried out in a joint collaboration between KCCH and the Pohang University of Science and Technology (POSTECH). Increasing desire for an uninterrupted, reliable and timely supply of the isotopes to customers has prompted obtaining a dedicated 5-13 MeV cyclotron for PET applications and pursuing the purchase of another 30MeV medical cyclotron in the very near future. A decision has been made to design the PET cyclotron in Korea. This will not only ease the problems associated with maintenance during operation but also keep the door open for continuous upgrading of the machine in the future

  5. Images to visualize the brain. PET: Positron Emission Tomography

    International Nuclear Information System (INIS)

    1992-01-01

    Diagnosis instrument and research tool, Positron Emission Tomography permits advanced technological developments on positron camera, on molecule labelling and principally on very complex 3D image processing. Cyceron Centre in Caen-France works on brain diseases and try to understand the mechanism of observed troubles and to assess the treatment efficiency with PET. Service Hospitalier Frederic Joliot of CEA-France establishes a mapping of cognitive functions in PET as vision areas, anxiety regions, brain organization of language, different attention forms, voluntary actions and motor functions

  6. PET and SPECT of neurobiological systems

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Gent Univ. (Belgium). Dept. of Nuclear Medicine; Otte, Andreas [Univ. of Applied Sciences, Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-04-01

    Addresses a variety of aspects of neurotransmission in the brain. Details the latest results in probe development. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT of Neurobiological Systems combines the expertise of renowned authors whose dedication to the development of novel probes and techniques for the investigation of neurobiological systems has achieved international recognition. Various aspects of neurotransmission in the brain are discussed, such as visualization and quantification of (more than 20 different) neuroreceptors, neuroinflammatory markers, transporters, and enzymes as well as neurotransmitter synthesis, ?-amyloid deposition, cerebral blood flow, and the metabolic rate of glucose. The latest results in probe development are also detailed. Most chapters are written jointly by radiochemists and nuclear medicine specialists to ensure a multidisciplinary approach. This state of the art compendium will be valuable to anyone in the field of clinical or preclinical neuroscience, from the radiochemist and radiologist/nuclear medicine specialist to the interested neurobiologist and general practitioner. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences. Other volumes focus on PET and SPECT in psychiatry and PET and SPECT in neurology''.

  7. Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding

    Energy Technology Data Exchange (ETDEWEB)

    Kolb, A., E-mail: armin.kolb@med.uni-tuebingen.de; Parl, C.; Liu, C. C.; Pichler, B. J. [Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University, 72076 Tübingen (Germany); Mantlik, F. [Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University, 72076 Tübingen, Germany and Department of Empirical Inference, Max Planck Institute for Intelligent Systems, 72076 Tübingen (Germany); Lorenz, E. [Max Planck Institute for Physics, Föhringer Ring 6, 80805 München (Germany); Renker, D. [Department of Physics, Technische Universität München, 85748 Garching (Germany)

    2014-08-15

    Purpose: The aim of this study was to develop a prototype PET detector module for a combined small animal positron emission tomography and magnetic resonance imaging (PET/MRI) system. The most important factor for small animal imaging applications is the detection sensitivity of the PET camera, which can be optimized by utilizing longer scintillation crystals. At the same time, small animal PET systems must yield a high spatial resolution. The measured object is very close to the PET detector because the bore diameter of a high field animal MR scanner is limited. When used in combination with long scintillation crystals, these small-bore PET systems generate parallax errors that ultimately lead to a decreased spatial resolution. Thus, we developed a depth of interaction (DoI) encoding PET detector module that has a uniform spatial resolution across the whole field of view (FOV), high detection sensitivity, compactness, and insensitivity to magnetic fields. Methods: The approach was based on Geiger mode avalanche photodiode (G-APD) detectors with cross-strip encoding. The number of readout channels was reduced by a factor of 36 for the chosen block elements. Two 12 × 2 G-APD strip arrays (25μm cells) were placed perpendicular on each face of a 12 × 12 lutetium oxyorthosilicate crystal block with a crystal size of 1.55 × 1.55 × 20 mm. The strip arrays were multiplexed into two channels and used to calculate the x, y coordinates for each array and the deposited energy. The DoI was measured in step sizes of 1.8 mm by a collimated {sup 18}F source. The coincident resolved time (CRT) was analyzed at all DoI positions by acquiring the waveform for each event and applying a digital leading edge discriminator. Results: All 144 crystals were well resolved in the crystal flood map. The average full width half maximum (FWHM) energy resolution of the detector was 12.8% ± 1.5% with a FWHM CRT of 1.14 ± 0.02 ns. The average FWHM DoI resolution over 12 crystals was 2.90

  8. Optimisation of a dual head semiconductor Compton camera using Geant4

    Energy Technology Data Exchange (ETDEWEB)

    Harkness, L.J. [Department of Physics, University of Liverpool, Oliver Lodge Laboratory, Liverpool L697ZE (United Kingdom)], E-mail: ljh@ns.ph.liv.ac.uk; Boston, A.J.; Boston, H.C.; Cooper, R.J.; Cresswell, J.R.; Grint, A.N.; Nolan, P.J.; Oxley, D.C.; Scraggs, D.P. [Department of Physics, University of Liverpool, Oliver Lodge Laboratory, Liverpool L697ZE (United Kingdom); Beveridge, T.; Gillam, J. [School of Physics and Materials Engineering, Monash University, Melbourne (Australia); Lazarus, I. [STFC Daresbury Laboratory, Warrington, Cheshire (United Kingdom)

    2009-06-01

    Conventional medical gamma-ray camera systems utilise mechanical collimation to provide information on the position of an incident gamma-ray photon. Systems that use electronic collimation utilising Compton image reconstruction techniques have the potential to offer huge improvements in sensitivity. Position sensitive high purity germanium (HPGe) detector systems are being evaluated as part of a single photon emission computed tomography (SPECT) Compton camera system. Data have been acquired from the orthogonally segmented planar SmartPET detectors, operated in Compton camera mode. The minimum gamma-ray energy which can be imaged by the current system in Compton camera configuration is 244 keV due to the 20 mm thickness of the first scatter detector which causes large gamma-ray absorption. A simulation package for the optimisation of a new semiconductor Compton camera has been developed using the Geant4 toolkit. This paper will show results of preliminary analysis of the validated Geant4 simulation for gamma-ray energies of SPECT, 141 keV.

  9. Specific recommendations for accurate and direct use of PET-CT in PET guided radiotherapy for head and neck sites

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, C. M., E-mail: christopher.thomas@gstt.nhs.uk; Convery, D. J.; Greener, A. G. [Guy' s and St. Thomas’ NHS Foundation Trust, Medical Physics Department, St. Thomas’ Hospital, London SE1 7EH (United Kingdom); Pike, L. C.; Baker, S.; Woods, E. [Division of Imaging Sciences and Biomedical Engineering, King' s College London, King' s Health Partners, St. Thomas’ Hospital, London SE1 7EH (United Kingdom); Hartill, C. E. [Guy' s and St. Thomas’ NHS Foundation Trust, Radiotherapy, Clinical Outpatients Clinic, St. Thomas’ Hospital, London SE1 7EH (United Kingdom)

    2014-04-15

    techniques, laser positioning may affect setup accuracy and couch deflection may be greater than scanners dedicated to radiotherapy. The full set of departmental commissioning and routine quality assurance tests applied to radiotherapy CT simulators must be carried out on the PET-CT scanner. CT image quality must be optimized for radiotherapy planning whilst understanding that the appearance will differ between scanners and may affect delineation. PET-CT quality assurance schedules will need to be added to and modified to incorporate radiotherapy quality assurance. Methods of working for radiotherapy and PET staff will change to take into account considerations of both parties. PET to CT alignment must be subject to quality control on a loaded and unloaded couch preferably using a suitable emission phantom, and tested throughout the whole data pathway. Data integrity must be tested throughout the whole pathway and a system included to verify that delineated structures are transferred correctly. Excellent multidisciplinary team communication and working is vital, and key staff members on both sides should be specifically dedicated to the project. Patient pathway should be clearly devised to optimize patient care and the resources of all departments. Recruitment of a cohort of patients into a methodology study is valuable to test the quality assurance methods and pathway.

  10. Specific recommendations for accurate and direct use of PET-CT in PET guided radiotherapy for head and neck sites

    International Nuclear Information System (INIS)

    Thomas, C. M.; Convery, D. J.; Greener, A. G.; Pike, L. C.; Baker, S.; Woods, E.; Hartill, C. E.

    2014-01-01

    techniques, laser positioning may affect setup accuracy and couch deflection may be greater than scanners dedicated to radiotherapy. The full set of departmental commissioning and routine quality assurance tests applied to radiotherapy CT simulators must be carried out on the PET-CT scanner. CT image quality must be optimized for radiotherapy planning whilst understanding that the appearance will differ between scanners and may affect delineation. PET-CT quality assurance schedules will need to be added to and modified to incorporate radiotherapy quality assurance. Methods of working for radiotherapy and PET staff will change to take into account considerations of both parties. PET to CT alignment must be subject to quality control on a loaded and unloaded couch preferably using a suitable emission phantom, and tested throughout the whole data pathway. Data integrity must be tested throughout the whole pathway and a system included to verify that delineated structures are transferred correctly. Excellent multidisciplinary team communication and working is vital, and key staff members on both sides should be specifically dedicated to the project. Patient pathway should be clearly devised to optimize patient care and the resources of all departments. Recruitment of a cohort of patients into a methodology study is valuable to test the quality assurance methods and pathway

  11. Monte Carlo modeling of a clinical PET scanner by using the GATE dedicated computer code; Modelagem Monte Carlo de um PET Scanner clinico utilizando o codigo dedicado GATE

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Igor Fagner; Lima, Fernando Roberto de Andrade, E-mail: falima@cnen.gov.b [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Universidade de Pernambuco (UPE), Recife, PE (Brazil). Escola Politecnica; Vieira, Jose Wilson [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2011-10-26

    This paper demonstrates more possible detailed the GATE simulated architecture involved in the 4D modeling of a General Electric PET scanner, the Advance. So, it were used data present in the literature on the configuration of GE modelled PET. The obtained results which were the 3D components of PET creation, and the simulation of 4D phenomena as the source decay and the gantry whirl, exhibit the potential of tool in emission tomograph modelling

  12. Cheetah: A high frame rate, high resolution SWIR image camera

    Science.gov (United States)

    Neys, Joel; Bentell, Jonas; O'Grady, Matt; Vermeiren, Jan; Colin, Thierry; Hooylaerts, Peter; Grietens, Bob

    2008-10-01

    A high resolution, high frame rate InGaAs based image sensor and associated camera has been developed. The sensor and the camera are capable of recording and delivering more than 1700 full 640x512pixel frames per second. The FPA utilizes a low lag CTIA current integrator in each pixel, enabling integration times shorter than one microsecond. On-chip logics allows for four different sub windows to be read out simultaneously at even higher rates. The spectral sensitivity of the FPA is situated in the SWIR range [0.9-1.7 μm] and can be further extended into the Visible and NIR range. The Cheetah camera has max 16 GB of on-board memory to store the acquired images and transfer the data over a Gigabit Ethernet connection to the PC. The camera is also equipped with a full CameralinkTM interface to directly stream the data to a frame grabber or dedicated image processing unit. The Cheetah camera is completely under software control.

  13. Current status and future perspective of PET

    International Nuclear Information System (INIS)

    Lee, Myung Chul

    2002-01-01

    Positron Emission Tomography (PET) is a nuclear medicine imaging modality that consists of systemic administration to a subject of a radiopharmaceutical labeled with a positron-emitting radionuclide. Following administration, its distribution in the organ or structure under study can be assessed as a function of time and space by (1) detecting the annihilation radiation resulting from the interaction of the positrons with matter, and (2) reconstructing the distribution of the radioactivity from a series of that used in computed tomography (CT). The nuclides most generally exhibit chemical properties that render them particularly desirable in physiological studies. The radionuclides most widely used in PET are F-18, C-11, O-15 and N-13. Regarding to the number of the current PET Centers worldwide (based on ICP data), more than 300 PET Centers were in operation in 2000. The use of PET technology grew rapidly compared to that in 1992 and 1996, particularly in the USA, which demonstrates a three-fold rise in PET installations. In 2001, 194 PET Centers were operating in the USA. In 1994, two clinical and research-oriented PET Centers at Seoul National University Hospital and Samsung Medical Center, was established as the first dedicated PET and Cyclotron machines in Korea, followed by two more PET facilities at the Korea Cancer Center Hospital, Ajou Medical Center, Yonsei University Medical Center, National Cancer Center and established their PET Center. Catholic Medical School and Pusan National University Hospital have finalized a plan to install PET machine in 2002, which results in total of nine PET Centers in Korea. Considering annual trends of PET application in four major PET centers in Korea in Asan Medical Center recent six years (from 1995 to 2000), a total of 11,564 patients have been studied every year and the number of PET studies has shown steep growth year upon year. We had, 1,020 PET patients in 1995. This number increased to 1,196, 1,756, 2,379, 3

  14. Brain {sup 18}F-FDG PET-MRI co registration: iconographic essay;PET-RM neurologico com FDG-{sup 18}F: ensaio iconografico

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcanti Filho, Jose Leite Gondim; Machado Neto, Luiz de Souza, E-mail: leite_jose@yahoo.co [Multi Imagem PET, Rio de Janeiro, RJ (Brazil); Fonseca, Lea Mirian Barbosa da; Gasparetto, Emerson Leandro [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Domingues, Romeu Cortes; Domingues, Roberto Cortes [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil)

    2010-05-15

    The combination of positron emission tomography (PET) with magnetic resonance imaging (MRI) has been the subject of several studies in recent years. Positron emission tomography is the most sensitive and specific imaging modality in the detection of metabolic changes, but presents limited spatial resolution. On the other hand, MRI presents a significant spatial resolution, besides evaluating soft tissues signal intensity with excellent contrast resolution. The present iconographic essay is aimed at demonstrating the potential clinical application of PET/MRI co registration. The studies were performed in a dedicated PET unit with {sup 18}F-fluorodeoxyglucose (FDG) as radiopharmaceutical and co registered with 1.5 T or 3 T brain MRI. The brain images fusion software presents an already well-established accuracy, so a significant synergy between a functional PET study and an excellent MRI anatomical detail is achieved. The most attractive clinical applications of this approach are the following: epileptogenic zone assessment in patients refractory to drug therapy, identification of patients with cognitive impairment at higher risk for progression to dementia and differentiation of dementias and Parkinsonian syndromes. (author)

  15. Automated radiochemical processing for clinical PET

    International Nuclear Information System (INIS)

    Padgett, H.C.; Schmidt, D.G.; Bida, G.T.; Wieland, B.W.; Pekrul, E.; Kingsbury, W.G.

    1991-01-01

    With the recent emergence of positron emission tomography (PET) as a viable clinical tool, there is a need for a convenient, cost-effective source of the positron emitter-labeled radiotracers labeled with carbon-11, nitrogen-13, oxygen-15, and fluorine-18. These short-lived radioisotopes are accelerator produced and thus, require a cyclotron and radiochemistry processing instrumentation that can be operated 3 in a clinical environment by competant technicians. The basic goal is to ensure safety and reliability while setting new standards for economy and ease of operation. The Siemens Radioisotope Delivery System (RDS 112) is a fully automated system dedicated to the production and delivery of positron-emitter labeled precursors and radiochemicals required to support a clinical PET imaging program. Thus, the entire RDS can be thought of as an automated radiochemical processing apparatus

  16. Fully integrated digital GAMMA camera-computer system

    International Nuclear Information System (INIS)

    Berger, H.J.; Eisner, R.L.; Gober, A.; Plankey, M.; Fajman, W.

    1985-01-01

    Although most of the new non-nuclear imaging techniques are fully digital, there has been a reluctance in nuclear medicine to abandon traditional analog planar imaging in favor of digital acquisition and display. The authors evaluated a prototype digital camera system (GE STARCAM) in which all of the analog acquisition components are replaced by microprocessor controls and digital circuitry. To compare the relative effects of acquisition matrix size on image quality and to ascertain whether digital techniques could be used in place of analog imaging, Tc-99m bone scans were obtained on this digital system and on a comparable analog camera in 10 patients. The dedicated computer is used for camera setup including definition of the energy window, spatial energy correction, and spatial distortion correction. The display monitor, which is used for patient positioning and image analysis, is 512/sup 2/ non-interlaced, allowing high resolution imaging. Data acquisition and processing can be performed simultaneously. Thus, the development of a fully integrated digital camera-computer system with optimized display should allow routine utilization of non-analog studies in nuclear medicine and the ultimate establishment of fully digital nuclear imaging laboratories

  17. [18F]FDG PET/MRI vs. PET/CT for whole-body staging in patients with recurrent malignancies of the female pelvis: initial results

    International Nuclear Information System (INIS)

    Beiderwellen, Karsten; Grueneisen, Johannes; Forsting, Michael; Lauenstein, Thomas C.; Umutlu, Lale; Ruhlmann, Verena; Buderath, Paul; Aktas, Bahriye; Heusch, Philipp; Kraff, Oliver

    2015-01-01

    To evaluate the diagnostic potential of PET/MRI with [ 18 F]FDG in recurrent ovarian and cervical cancer in comparison to PET/CT. A group of 19 patients with suspected recurrence of pelvic malignancies (ovarian cancer, 11 patients; cervical cancer, 8 patients) scheduled for an [ 18 F]FDG PET/CT were subsequently enrolled for a PET/MRI. The scan protocol comprised: (1) a T1-W axial VIBE after contrast agent adminstration, (2) an axial T2-W HASTE, (3) a coronal TIRM, (4) an axial DWI, and dedicated MR sequences of the female pelvis including (5) a T1-W VIBE before contrast agent adminstration, (6) a sagittal T2-W TSE, and (7) a sagittal T1-W dynamic VIBE. The datasets (PET/CT, PET/MRI) were rated separately by two readers regarding lesion count, lesion localization, lesion conspicuity (four-point scale), lesion characterization (benign/malignant/indeterminate) and diagnostic confidence (three-point scale). All available data (histology, prior examinations, PET/CT, PET/MRI, follow-up examinations) served as standard of reference. Median values were compared using the Wilcoxon rank sum test. Metastatic lesions were present in 16 of the 19 patients. A total of 78 lesions (malignant, 58; benign, 20) were described. Both PET/CT and PET/MRI allowed correct identification of all malignant lesions and provided equivalent conspicuity (3.86 ± 0.35 for PET/CT, 3.91 ± 0.28 for PET/MRI; p > 0.05). Diagnostic confidence was significantly higher for PET/MRI in malignant (p < 0.01) and benign lesions (p < 0.05). Both PET/CT and PET/MRI offer an equivalently high diagnostic value for recurrent pelvic malignancies. PET/MRI offers higher diagnostic confidence in the discrimination of benign and malignant lesions. Considering the reduced radiation dose and superior lesion discrimination, PET/MRI may serve as a powerful alternative to PET/CT in the future. (orig.)

  18. Novel Geometrical Concept of a High Performance Brain PET Scanner Principle, Design and Performance Estimates

    CERN Document Server

    Séguinot, Jacques; Chesi, Enrico Guido; Joram, C; Mathot, S; Weilhammer, P; Chamizo-Llatas, M; Correia, J G; Ribeiro da Silva, M; Garibaldi, F; De Leo, R; Nappi, E; Corsi, F; Dragone, A; Schoenahl, F; Zaidi, H

    2006-01-01

    We present the principle, a possible implementation and performance estimates of a novel geometrical concept for a high resolution positron emission tomograph. The concept, which can for example be implemented in a brain PET device, promisses to lead to an essentially parallax free 3D image reconstruction with excellent spatial resolution and constrast, uniform over the complete field of view. The key components are matrices of long axially oriented scintillator crystals which are read out at both extremities by segmented Hybrid Photon Detectors. We discuss the relevant design considerations for a 3D axial PET camera module, motivate parameter and material choices, and estimate its performance in terms of spatial and energy resolution. We support these estimates by Monte Carlo simulations and in some cases by first experimental results. From the performance of a camera module, we extrapolate to the reconstruction resolution of a 3D axial PET scanner in a semi-analytical way and compare it to an existing state...

  19. 18F-FDG PET in children with lymphomas

    International Nuclear Information System (INIS)

    Depas, Gisele; Barsy, Caroline De; Foidart, Jacqueline; Rigo, Pierre; Hustinx, Roland; Jerusalem, Guy; Hoyoux, Claire; Dresse, Marie-Francoise; Fassotte, Marie-France; Paquet, Nancy

    2005-01-01

    The aim of this study was to retrospectively evaluate the performance of positron emission tomography (PET) with 18 F-fluorodeoxyglucose ( 18 F-FDG) in children with lymphomas, at various stages of their disease. Twenty-eight children (mean age 12.5 years, 14 girls, 14 boys) with Hodgkin's disease (HD, n=17) or non-Hodgkin's lymphoma (NHL, n=11) were evaluated. Patients were investigated at initial staging (n=19), early in the course of treatment (n=19), at the end of treatment (n=16) and during long-term follow-up (n=19). A total of 113 whole-body PET studies were performed on dedicated scanners. PET results were compared with the results of conventional methods (CMs) such as physical examination, laboratory studies, chest X-rays, computed tomography, magnetic resonance imaging, ultrasonography and bone scan when available. At initial evaluation (group 1), PET changed the disease stage and treatment in 10.5% of the cases. In early evaluation of the response to treatment (group 2), PET failed to predict two relapses and one incomplete response to treatment. In this group, however, PET did not show any false positive results. There were only 4/75 false positive results for PET among patients studied at the end of treatment (group 3, specificity 94%) or during the systematic follow-up (group 4, specificity 95%), as compared with 27/75 for CMs (specificity 54% and 66%, respectively). 18 F-FDG-PET is a useful tool for evaluating children with lymphomas. Large prospective studies are needed to appreciate its real impact on patient management. (orig.)

  20. Fusion of PET and MRI for Hybrid Imaging

    Science.gov (United States)

    Cho, Zang-Hee; Son, Young-Don; Kim, Young-Bo; Yoo, Seung-Schik

    Recently, the development of the fusion PET-MRI system has been actively studied to meet the increasing demand for integrated molecular and anatomical imaging. MRI can provide detailed anatomical information on the brain, such as the locations of gray and white matter, blood vessels, axonal tracts with high resolution, while PET can measure molecular and genetic information, such as glucose metabolism, neurotransmitter-neuroreceptor binding and affinity, protein-protein interactions, and gene trafficking among biological tissues. State-of-the-art MRI systems, such as the 7.0 T whole-body MRI, now can visualize super-fine structures including neuronal bundles in the pons, fine blood vessels (such as lenticulostriate arteries) without invasive contrast agents, in vivo hippocampal substructures, and substantia nigra with excellent image contrast. High-resolution PET, known as High-Resolution Research Tomograph (HRRT), is a brain-dedicated system capable of imaging minute changes of chemicals, such as neurotransmitters and -receptors, with high spatial resolution and sensitivity. The synergistic power of the two, i.e., ultra high-resolution anatomical information offered by a 7.0 T MRI system combined with the high-sensitivity molecular information offered by HRRT-PET, will significantly elevate the level of our current understanding of the human brain, one of the most delicate, complex, and mysterious biological organs. This chapter introduces MRI, PET, and PET-MRI fusion system, and its algorithms are discussed in detail.

  1. Development of PET in Latin America. Experience of the first PET-Cyclotron Center

    International Nuclear Information System (INIS)

    Tutor, C.A.; Frias, L.

    2002-01-01

    Mendoza's government. This local economic condition allowed our institution to install the cyclotron and the PET camera in 1997. A staff trained abroad made possible the first 18 FDG studies in 1999 and despite the efforts to run the center, 18 FDG-PET images have shown us an improvement in cost-effectiveness of the patient's treatment, making the effort worthy. Even knowing about the risk and benefits of running a PET -Cyclotron Center, we encourage installing other centers in Latin America in the near future

  2. Performance of a YSO/LSO detector block for use in a PET/SPECT system

    International Nuclear Information System (INIS)

    Dahlbom, M.; MacDonald, L.R.; Eriksson, L.

    1996-01-01

    In recent years, there has been an increased interest in using conventional SPECT scintillation cameras for PET imaging, however, the count rate performance is a limiting factor. The modular block detectors used in modem PET systems do not have this limitation. In this work, the performance of a detector block design which would have high resolution and high count rate capabilities in both detection modes is studied. The high light output of LSO (∼5-6 times BGO) would allow the construction of a detector block that would have similar intrinsic resolution characteristics at 140 keV as a conventional high resolution BGO block detector at 511 keV (∼4 mm FWHM). However, the intrinsic radioactivity of LSO prevents the use of this scintillator in single photon counting mode. YSO is a scintillator with higher light output than LSO but worse absorption characteristics than LSO. YSO and LSO could be combined in a phoswich detector block, where YSO is placed in a front layer and is used for low energy (SPECT) imaging and LSO in a second layer is used for PET imaging. Events in the two detector materials can be separated by pulse shape discrimination, since the decay times of the light in YSO and LSO are different (70 and 40 ns, respectively). Although the intrinsic resolution of the block detector with discrete elements is worse than for a NaI camera, this would not be a limiting factor. Simulations of a 20 cm diameter hot spot phantom imaged at different collimator distances using a high resolution collimator and scintillation camera system was compared to a block detector camera. No appreciable difference in resolution was seen in the reconstructed images between the two camera systems, including the ideal situation of zero distance between collimator and phantom

  3. Radiation monitoring of PET staff

    International Nuclear Information System (INIS)

    Trang, A.

    2004-01-01

    Full text: Positron emission tomography (PET) is becoming a common diagnostic tool in hospitals, often located in and employing staff from the Nuclear Medicine or Radiology departments. Although similar in some ways, staff in PET departments are commonly found to have the highest radiation doses in the hospital environment due to unique challenges which PET tracers present in administration as well as production. The establishment of a PET centre with a dedicated cyclotron has raised concerns of radiation protection to the staff at the WA PET Centre and the Radiopharmaceutical Production and Development (RAPID) team. Since every PET centre has differing designs and practices, it was considered important to closely monitor the radiation dose to our staff so that improvements to practices and design could be made to reduce radiation dose. Electronic dosimeters (MGP DMC 2000XB), which have a facility to log time and dose at 10 second intervals, were provided to three PET technologists and three PET nurses. These were worn in the top pocket of their lab coats throughout a whole day. Each staff member was then asked to note down their duties throughout the day and also note the time they performed each duty. The duties would then correlate with the dose with which the electronic monitor recorded and an estimate of radiation dose per duty could be given. Also an estimate of the dose per day to each staff member could be made. PET nurses averaged approximately 20 μ8v per day getting their largest dose from caring for occasional problematic patients. Smaller doses of a 1-2 μ8v were recorded for injections and removing cannulas. PET technologists averaged approximately 15 μ8v per day getting their largest dose of 1-5μ8v mainly from positioning of patients and sometimes larger doses due to problematic patients. Smaller doses of 1-2 μ5v were again recorded for injections and removal of cannulas. Following a presentation given to staff, all WA PET Centre and RAPID staff

  4. Hybrid PET/MRI insert: B0 field optimization by applying active and passive shimming on PET detector level

    Energy Technology Data Exchange (ETDEWEB)

    Wehner, Jakob [Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen (Germany); Weissler, Bjoern [Philips Research Europe, Aachen (Germany); Schulz, Volkmar [Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen (Germany); Philips Research Europe, Aachen (Germany)

    2014-07-29

    Combining PET and MRI into a hybrid device is challenging since both systems might influence each other. A typical interference problem of such a combined device is the distortion of the MRI’s B{sub 0} field distribution due to the material brought inside the MRI’s FOV which is in particular challenging for small-bore PET-systems. High field homogeneity is needed for a good MRI acquisition in general as well as in certain applications. Typically, active shimming using dedicated coils is applied to improve the field homogeneity. However, these techniques are limited especially for localized distortion profiles with higher-order characteristics caused by PET/MRI inserts. As a consequence, we are exploring the potential application of shimming on PET detector level (for the Hyperion-II{sup D} PET/MRI insert), meaning that the distortion profile caused by PET modules is compensated using additional magnetic materials (passive shimming) and DC coils (active shimming). To explore the technique, B{sub 0} field measurements have been performed using a whole-body phantom in combination with the MRI body coil. An FFE sequence was used to measure distortion maps of DC loops and small magnetic objects (capacitors, ferrites). These distortion maps served as input for a software framework which has been written to perform the field optimization. The implementation was verified by measurements and fits were performed to extract characteristic parameters of the tested objects. Finally, the implemented software framework was used to homogenize a measured distortion map produced by a single PET module by superimposing distortion corrections from additional simulated materials. The resulting superimposed distortion map showed a significantly improved B{sub 0} field map quality (reduced spectral width and improved homogeneity). The simulated susceptibility distribution will be applied on PET module level and tested in experiments. Results and details about this study will be

  5. Clear-PEM: A PET imaging system dedicated to breast cancer diagnostics

    CERN Document Server

    Abreu, M C; Albuquerque, E; Almeida, F G; Almeida, P; Amaral, P; Auffray, Etiennette; Bento, P; Bruyndonckx, P; Bugalho, R; Carriço, B; Cordeiro, H; Ferreira, M; Ferreira, N C; Gonçalves, F; Lecoq, Paul; Leong, C; Lopes, F; Lousã, P; Luyten, J; Martins, M V; Matela, N; Rato-Mendes, P; Moura, R; Nobre, J; Oliveira, N; Ortigão, C; Peralta, L; Rego, J; Ribeiro, R; Rodrigues, P; Santos, A I; Silva, J C; Silva, M M; Tavernier, Stefaan; Teixeira, I C; Texeira, J P; Trindade, A; Trummer, Julia; Varela, J

    2007-01-01

    The Clear-PEM scanner for positron emission mammography under development is described. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes and readout by a fast low-noise electronic system. A dedicated digital trigger (TGR) and data acquisition (DAQ) system is used for on-line selection of coincidence events with high efficiency, large bandwidth and small dead-time. A specialized gantry allows to perform exams of the breast and of the axilla. In this paper we present results of the measurement of detector modules that integrate the system under construction as well as the imaging performance estimated from Monte Carlo simulated data.

  6. Correcting for respiratory motion in liver PET/MRI: preliminary evaluation of the utility of bellows and navigated hepatobiliary phase imaging

    International Nuclear Information System (INIS)

    Hope, Thomas A.; Verdin, Emily F.; Bergsland, Emily K.; Ohliger, Michael A.; Corvera, Carlos University; Nakakura, Eric K.

    2015-01-01

    The purpose of this study was to evaluate the utility of bellows-based respiratory compensation and navigated hepatobiliary phase imaging to correct for respiratory motion in the setting of dedicated liver PET/MRI. Institutional review board approval and informed consent were obtained. Six patients with metastatic neuroendocrine tumor were imaged using Ga-68 DOTA-TOC PET/MRI. Whole body imaging and a dedicated 15-min liver PET acquisition was performed, in addition to navigated and breath-held hepatobiliary phase (HBP) MRI. Liver PET data was reconstructed three ways: the entire data set (liver PET), gated using respiratory bellows (RC-liver PET), and a non-gated data set reconstructed using the same amount of data used in the RC-liver PET (shortened liver PET). Liver lesions were evaluated using SUV max , SUV peak , SUV mean , and Vol isocontour . Additionally, the displacement of each lesion between the RC-liver PET images and the navigated and breath-held HBP images was calculated. Respiratory compensation resulted in a 43 % increase in SUVs compared to ungated data (liver vs RC-liver PET SUV max 26.0 vs 37.3, p < 0.001) and a 25 % increase compared to a non-gated reconstruction using the same amount of data (RC-liver vs shortened liver PET SUV max 26.0 vs 32.6, p < 0.001). Lesion displacement was minimized using navigated HBP MRI (1.3 ± 1.0 mm) compared to breath-held HBP MRI (23.3 ± 1.0 mm). Respiratory bellows can provide accurate respiratory compensation when imaging liver lesions using PET/MRI, and results in increased SUVs due to a combination of increased image noise and reduced respiratory blurring. Additionally, navigated HBP MRI accurately aligns with respiratory compensated PET data.

  7. Correcting for respiratory motion in liver PET/MRI: preliminary evaluation of the utility of bellows and navigated hepatobiliary phase imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hope, Thomas A. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Department of Radiology, San Francisco VA Medical Center, San Francisco, CA (United States); Verdin, Emily F. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Bergsland, Emily K. [Division of Hematology/Oncology, Department of Medicine, University of California, San Francisco, San Francisco, CA (United States); Ohliger, Michael A. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Department of Radiology, San Francisco General Hospital, San Francisco, CA (United States); Corvera, Carlos University; Nakakura, Eric K. [Division of Surgical Oncology, Department of Surgery, University of California, San Francisco, San Francisco, CA (United States)

    2015-09-18

    The purpose of this study was to evaluate the utility of bellows-based respiratory compensation and navigated hepatobiliary phase imaging to correct for respiratory motion in the setting of dedicated liver PET/MRI. Institutional review board approval and informed consent were obtained. Six patients with metastatic neuroendocrine tumor were imaged using Ga-68 DOTA-TOC PET/MRI. Whole body imaging and a dedicated 15-min liver PET acquisition was performed, in addition to navigated and breath-held hepatobiliary phase (HBP) MRI. Liver PET data was reconstructed three ways: the entire data set (liver PET), gated using respiratory bellows (RC-liver PET), and a non-gated data set reconstructed using the same amount of data used in the RC-liver PET (shortened liver PET). Liver lesions were evaluated using SUV{sub max}, SUV{sub peak}, SUV{sub mean}, and Vol{sub isocontour}. Additionally, the displacement of each lesion between the RC-liver PET images and the navigated and breath-held HBP images was calculated. Respiratory compensation resulted in a 43 % increase in SUVs compared to ungated data (liver vs RC-liver PET SUV{sub max} 26.0 vs 37.3, p < 0.001) and a 25 % increase compared to a non-gated reconstruction using the same amount of data (RC-liver vs shortened liver PET SUV{sub max} 26.0 vs 32.6, p < 0.001). Lesion displacement was minimized using navigated HBP MRI (1.3 ± 1.0 mm) compared to breath-held HBP MRI (23.3 ± 1.0 mm). Respiratory bellows can provide accurate respiratory compensation when imaging liver lesions using PET/MRI, and results in increased SUVs due to a combination of increased image noise and reduced respiratory blurring. Additionally, navigated HBP MRI accurately aligns with respiratory compensated PET data.

  8. Initial reconstruction results from a simulated adaptive small animal C shaped PET/MR insert

    Energy Technology Data Exchange (ETDEWEB)

    Efthimiou, Nikos [Technological Educational Institute of Athens (Greece); Kostou, Theodora; Papadimitroulas, Panagiotis [Technological Educational Institute of Athens (Greece); Department of Medical Physics, School of Medicine, University of Patras (Greece); Charalampos, Tsoumpas [Division of Biomedical Imaging, University of Leeds, Leeds (United Kingdom); Loudos, George [Technological Educational Institute of Athens (Greece)

    2015-05-18

    Traditionally, most clinical and preclinical PET scanners, rely on full cylindrical geometry for whole body as well as dedicated organ scans, which is not optimized with regards to sensitivity and resolution. Several groups proposed the construction of dedicated PET inserts for MR scanners, rather than the construction of new integrated PET/MR scanners. The space inside an MR scanner is a limiting factor which can be reduced further with the use of extra coils, and render the use of non-flexible cylindrical PET scanners difficult if not impossible. The incorporation of small SiPM arrays, can provide the means to design adaptive PET scanners to fit in tight locations, which, makes imaging possible and improve the sensitivity, due to the closer approximation to the organ of interest. In order to assess the performance of such a device we simulated the geometry of a C shaped PET, using GATE. The design of the C-PET was based on a realistic SiPM-BGO scenario. In order reconstruct the simulated data, with STIR, we had to calculate system probability matrix which corresponds to this non standard geometry. For this purpose we developed an efficient multi threaded ray tracing technique to calculate the line integral paths in voxel arrays. One of the major features is the ability to automatically adjust the size of FOV according to the geometry of the detectors. The initial results showed that the sensitivity improved as the angle between the detector arrays increases, thus better angular sampling the scanner's field of view (FOV). The more complete angular coverage helped in improving the shape of the source in the reconstructed images, as well. Furthermore, by adapting the FOV to the closer to the size of the source, the sensitivity per voxel is improved.

  9. Initial reconstruction results from a simulated adaptive small animal C shaped PET/MR insert

    International Nuclear Information System (INIS)

    Efthimiou, Nikos; Kostou, Theodora; Papadimitroulas, Panagiotis; Charalampos, Tsoumpas; Loudos, George

    2015-01-01

    Traditionally, most clinical and preclinical PET scanners, rely on full cylindrical geometry for whole body as well as dedicated organ scans, which is not optimized with regards to sensitivity and resolution. Several groups proposed the construction of dedicated PET inserts for MR scanners, rather than the construction of new integrated PET/MR scanners. The space inside an MR scanner is a limiting factor which can be reduced further with the use of extra coils, and render the use of non-flexible cylindrical PET scanners difficult if not impossible. The incorporation of small SiPM arrays, can provide the means to design adaptive PET scanners to fit in tight locations, which, makes imaging possible and improve the sensitivity, due to the closer approximation to the organ of interest. In order to assess the performance of such a device we simulated the geometry of a C shaped PET, using GATE. The design of the C-PET was based on a realistic SiPM-BGO scenario. In order reconstruct the simulated data, with STIR, we had to calculate system probability matrix which corresponds to this non standard geometry. For this purpose we developed an efficient multi threaded ray tracing technique to calculate the line integral paths in voxel arrays. One of the major features is the ability to automatically adjust the size of FOV according to the geometry of the detectors. The initial results showed that the sensitivity improved as the angle between the detector arrays increases, thus better angular sampling the scanner's field of view (FOV). The more complete angular coverage helped in improving the shape of the source in the reconstructed images, as well. Furthermore, by adapting the FOV to the closer to the size of the source, the sensitivity per voxel is improved.

  10. [{sup 18}F]FDG PET/MRI vs. PET/CT for whole-body staging in patients with recurrent malignancies of the female pelvis: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Beiderwellen, Karsten; Grueneisen, Johannes; Forsting, Michael; Lauenstein, Thomas C.; Umutlu, Lale [University Hospital Essen, University of Duisburg-Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Ruhlmann, Verena [University Hospital Essen, University of Duisburg-Essen, Clinic for Nuclear Medicine, Essen (Germany); Buderath, Paul; Aktas, Bahriye [University Hospital Essen, University of Duisburg-Essen, Clinic for Obstetrics and Gynecology, Essen (Germany); Heusch, Philipp [University of Dusseldorf, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Kraff, Oliver [University of Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany)

    2015-01-15

    To evaluate the diagnostic potential of PET/MRI with [{sup 18}F]FDG in recurrent ovarian and cervical cancer in comparison to PET/CT. A group of 19 patients with suspected recurrence of pelvic malignancies (ovarian cancer, 11 patients; cervical cancer, 8 patients) scheduled for an [{sup 18}F]FDG PET/CT were subsequently enrolled for a PET/MRI. The scan protocol comprised: (1) a T1-W axial VIBE after contrast agent adminstration, (2) an axial T2-W HASTE, (3) a coronal TIRM, (4) an axial DWI, and dedicated MR sequences of the female pelvis including (5) a T1-W VIBE before contrast agent adminstration, (6) a sagittal T2-W TSE, and (7) a sagittal T1-W dynamic VIBE. The datasets (PET/CT, PET/MRI) were rated separately by two readers regarding lesion count, lesion localization, lesion conspicuity (four-point scale), lesion characterization (benign/malignant/indeterminate) and diagnostic confidence (three-point scale). All available data (histology, prior examinations, PET/CT, PET/MRI, follow-up examinations) served as standard of reference. Median values were compared using the Wilcoxon rank sum test. Metastatic lesions were present in 16 of the 19 patients. A total of 78 lesions (malignant, 58; benign, 20) were described. Both PET/CT and PET/MRI allowed correct identification of all malignant lesions and provided equivalent conspicuity (3.86 ± 0.35 for PET/CT, 3.91 ± 0.28 for PET/MRI; p > 0.05). Diagnostic confidence was significantly higher for PET/MRI in malignant (p < 0.01) and benign lesions (p < 0.05). Both PET/CT and PET/MRI offer an equivalently high diagnostic value for recurrent pelvic malignancies. PET/MRI offers higher diagnostic confidence in the discrimination of benign and malignant lesions. Considering the reduced radiation dose and superior lesion discrimination, PET/MRI may serve as a powerful alternative to PET/CT in the future. (orig.)

  11. Computer vision camera with embedded FPGA processing

    Science.gov (United States)

    Lecerf, Antoine; Ouellet, Denis; Arias-Estrada, Miguel

    2000-03-01

    Traditional computer vision is based on a camera-computer system in which the image understanding algorithms are embedded in the computer. To circumvent the computational load of vision algorithms, low-level processing and imaging hardware can be integrated in a single compact module where a dedicated architecture is implemented. This paper presents a Computer Vision Camera based on an open architecture implemented in an FPGA. The system is targeted to real-time computer vision tasks where low level processing and feature extraction tasks can be implemented in the FPGA device. The camera integrates a CMOS image sensor, an FPGA device, two memory banks, and an embedded PC for communication and control tasks. The FPGA device is a medium size one equivalent to 25,000 logic gates. The device is connected to two high speed memory banks, an IS interface, and an imager interface. The camera can be accessed for architecture programming, data transfer, and control through an Ethernet link from a remote computer. A hardware architecture can be defined in a Hardware Description Language (like VHDL), simulated and synthesized into digital structures that can be programmed into the FPGA and tested on the camera. The architecture of a classical multi-scale edge detection algorithm based on a Laplacian of Gaussian convolution has been developed to show the capabilities of the system.

  12. Initial clinical results of simultaneous {sup 18}F-FDG PET/MRI in comparison to {sup 18}F-FDG PET/CT in patients with head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kubiessa, K.; Gawlitza, M.; Kuehn, A.; Fuchs, J.; Kahn, T.; Stumpp, P. [University Hospital of Leipzig, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Purz, S.; Steinhoff, K.G.; Sabri, O.; Kluge, R. [University Hospital of Leipzig, Department of Nuclear Medicine, Leipzig (Germany); Boehm, A. [University Hospital of Leipzig, ENT Department, Leipzig (Germany)

    2014-04-15

    The aim of this study was to evaluate the diagnostic capability of simultaneous {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/MRI compared to {sup 18}F-FDG PET/CT as well as their single components in head and neck cancer patients. In a prospective study 17 patients underwent {sup 18}F-FDG PET/CT for staging or follow-up and an additional {sup 18}F-FDG PET/MRI scan with whole-body imaging and dedicated examination of the neck. MRI, CT and PET images as well as PET/MRI and PET/CT examinations were evaluated independently and in a blinded fashion by two reader groups. Results were compared with the reference standard (final diagnosis determined in consensus using all available data including histology and follow-up). Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. A total of 23 malignant tumours were found with the reference standard. PET/CT showed a sensitivity of 82.7 %, a specificity of 87.3 %, a PPV of 73.2 % and a NPV of 92.4 %. Corresponding values for PET/MRI were 80.5, 88.2, 75.6 and 92.5 %. No statistically significant difference in diagnostic capability could be found between PET/CT and PET/MRI. Evaluation of the PET part from PET/CT revealed highest sensitivity of 95.7 %, and MRI showed best specificity of 96.4 %. There was a high inter-rater agreement in all modalities (Cohen's kappa 0.61-0.82). PET/MRI of patients with head and neck cancer yielded good diagnostic capability, similar to PET/CT. Further studies on larger cohorts to prove these first results seem justified. (orig.)

  13. Poster - 01: LabPET II Pixelated APD-Based PET Scanner for High-Resolution Preclinical Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lecomte, Roger; Arpin, Louis; Beaudoin, Jean-François; Bergeron, Mélanie; Bouchard, Jonathan; Bouziri, Haithem; Cadorette, Jules; Gaudin, Émilie; Jürgensen, Nadia; Koua, Konin Calliste; Trépanier, Pierre-Yves Lauzier; Leroux, Jean-Daniel; Loignon-Houle, Francis; Njejimana, Larissa; Paillé, Maxime; Paulin, Caroline; Pepin, Catherine; Pratte, Jean-François; Samson, Arnaud; Thibaudeau, Christian [Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, Université de Sherbrooke, Université de Sherbrooke, 3IT, Université de Sherbrooke, Novalgo Inc., Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, 3IT, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, 3IT, Université de Sherbrooke (Canada); and others

    2016-08-15

    Purpose: LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using truly pixelated detectors and highly integrated parallel front-end processing electronics. Methods: The basic element uses a 4×8 array of 1.12×1.12 mm{sup 2} Lu{sub 1.9}Y{sub 0.1}SiO{sub 5}:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4×8 pixelated monolithic APD array mounted on a ceramic carrier. Four detector arrays are mounted on a daughter board carrying two flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was implemented in silico by encoding time and energy information using a dual-threshold Time-over-Threshold (ToT) scheme. The self-contained 128-channel detector module was designed as a generic component for ultra-high resolution PET imaging of small to medium-size animals. Results: Energy and timing performance were optimized by carefully setting ToT thresholds to minimize the noise/slope ratio. ToT spectra clearly show resolved 511 keV photopeak and Compton edge with ToT resolution well below 10%. After correction for nonlinear ToT response, energy resolution is typically 24±2% FWHM. Coincidence time resolution between opposing 128-channel modules is below 4 ns FWHM. Initial imaging results demonstrate that 0.8 mm hot spots of a Derenzo phantom can be resolved. Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed and shown to achieve a spatial resolution approaching the physical limit of PET. Future plans are to integrate a small-bore dedicated mouse version of the scanner within a PET/CT platform.

  14. Health Examination by PET. (1) Cancer Examination

    International Nuclear Information System (INIS)

    Uno, Koichi

    2006-01-01

    Cancer examination by positron emission tomography (PET) started in Japan in 1994 and has been rapidly popularized. This paper describes author's experience of the examination in his hospital along the recent Japanese guideline for the PET cancer examination. Fluorodeoxyglucose (FDG) is intravenously injected at 3.7 (or 4.6, for diabetic patients) MBq/kg after 4-5 hr fasting and 40 min later, imaging is conducted with additional delayed scan at 2 hr to reduce the possible false positive. Image is taken by the equipment with PET-specific camera, of which quality assurance (QA) is maintained according to the guideline, and 3D image is constructed by the ordered subset expectation maximization method. Number of examinees during 4.5 years are 18,210 (M/F=9,735/8,475), and 236 (1.3%), together with use of other test measures like ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), biochemical marker and occult blood as well, are found to have cancer of thyroid, large bowel, lung, breast and others. The false negative rate by PET alone is 78/236 (33%) for cancer. PET examination has problems of image reading and specificity of organs, and tasks of informed consent, test cost, increased exchange of information and radiation exposure. However, PET cancer examination will be established as a routine diagnostic tool when the accumulated evidence of early cancer detection is shown useful for improving the survival rate and for reducing the medicare cost. (T.I.)

  15. Fast and Practical Head Tracking in Brain Imaging with Time-of-Flight Camera

    DEFF Research Database (Denmark)

    Wilm, Jakob; Olesen, Oline Vinter; Jensen, Rasmus Ramsbøl

    2013-01-01

    scanners. Particularly in MRI and PET, the newest generation of TOF cameras could become a method of tracking small and large scale patient movement in a fast and user friendly way required in clinical environments. We present a novel methodology for fast tracking from TOF point clouds without the need...

  16. Motion and Emotional Behavior Design for Pet Robot Dog

    Science.gov (United States)

    Cheng, Chi-Tai; Yang, Yu-Ting; Miao, Shih-Heng; Wong, Ching-Chang

    A pet robot dog with two ears, one mouth, one facial expression plane, and one vision system is designed and implemented so that it can do some emotional behaviors. Three processors (Inter® Pentium® M 1.0 GHz, an 8-bit processer 8051, and embedded soft-core processer NIOS) are used to control the robot. One camera, one power detector, four touch sensors, and one temperature detector are used to obtain the information of the environment. The designed robot with 20 DOF (degrees of freedom) is able to accomplish the walking motion. A behavior system is built on the implemented pet robot so that it is able to choose a suitable behavior for different environmental situation. From the practical test, we can see that the implemented pet robot dog can do some emotional interaction with the human.

  17. Spatial resolution of the HRRT PET scanner using 3D-OSEM PSF reconstruction

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Sibomana, Merence; Keller, Sune Høgild

    2009-01-01

    The spatial resolution of the Siemens High Resolution Research Tomograph (HRRT) dedicated brain PET scanner installed at Copenhagen University Hospital (Rigshospitalet) was measured using a point-source phantom with high statistics. Further, it was demonstrated how the newly developed 3D-OSEM PSF...

  18. Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET

    Science.gov (United States)

    Moliner, L.; Correcher, C.; González, A. J.; Conde, P.; Hernández, L.; Orero, A.; Rodríguez-Álvarez, M. J.; Sánchez, F.; Soriano, A.; Vidal, L. F.; Benlloch, J. M.

    2013-02-01

    In this work we present an innovative algorithm for the reconstruction of PET images based on the List-Mode (LM) technique which improves their spatial resolution compared to results obtained with current MLEM algorithms. This study appears as a part of a large project with the aim of improving diagnosis in early Alzheimer disease stages by means of a newly developed hybrid PET-MR insert. At the present, Alzheimer is the most relevant neurodegenerative disease and the best way to apply an effective treatment is its early diagnosis. The PET device will consist of several monolithic LYSO crystals coupled to SiPM detectors. Monolithic crystals can reduce scanner costs with the advantage to enable implementation of very small virtual pixels in their geometry. This is especially useful for LM reconstruction algorithms, since they do not need a pre-calculated system matrix. We have developed an LM algorithm which has been initially tested with a large aperture (186 mm) breast PET system. Such an algorithm instead of using the common lines of response, incorporates a novel calculation of tubes of response. The new approach improves the volumetric spatial resolution about a factor 2 at the border of the field of view when compared with traditionally used MLEM algorithm. Moreover, it has also shown to decrease the image noise, thus increasing the image quality.

  19. Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET

    International Nuclear Information System (INIS)

    Moliner, L.; Correcher, C.; González, A.J.; Conde, P.; Hernández, L.; Orero, A.; Rodríguez-Álvarez, M.J.; Sánchez, F.; Soriano, A.; Vidal, L.F.; Benlloch, J.M.

    2013-01-01

    In this work we present an innovative algorithm for the reconstruction of PET images based on the List-Mode (LM) technique which improves their spatial resolution compared to results obtained with current MLEM algorithms. This study appears as a part of a large project with the aim of improving diagnosis in early Alzheimer disease stages by means of a newly developed hybrid PET-MR insert. At the present, Alzheimer is the most relevant neurodegenerative disease and the best way to apply an effective treatment is its early diagnosis. The PET device will consist of several monolithic LYSO crystals coupled to SiPM detectors. Monolithic crystals can reduce scanner costs with the advantage to enable implementation of very small virtual pixels in their geometry. This is especially useful for LM reconstruction algorithms, since they do not need a pre-calculated system matrix. We have developed an LM algorithm which has been initially tested with a large aperture (186 mm) breast PET system. Such an algorithm instead of using the common lines of response, incorporates a novel calculation of tubes of response. The new approach improves the volumetric spatial resolution about a factor 2 at the border of the field of view when compared with traditionally used MLEM algorithm. Moreover, it has also shown to decrease the image noise, thus increasing the image quality

  20. Towards Implementing an MR-based PET Attenuation Correction Method for Neurological Studies on the MR-PET Brain Prototype

    Science.gov (United States)

    Catana, Ciprian; van der Kouwe, Andre; Benner, Thomas; Michel, Christian J.; Hamm, Michael; Fenchel, Matthias; Fischl, Bruce; Rosen, Bruce; Schmand, Matthias; Sorensen, A. Gregory

    2013-01-01

    A number of factors have to be considered for implementing an accurate attenuation correction (AC) in a combined MR-PET scanner. In this work, some of these challenges were investigated and an AC method based entirely on the MR data obtained with a single dedicated sequence was developed and used for neurological studies performed with the MR-PET human brain scanner prototype. Methods The focus was on the bone/air segmentation problem, the bone linear attenuation coefficient selection and the RF coil positioning. The impact of these factors on the PET data quantification was studied in simulations and experimental measurements performed on the combined MR-PET scanner. A novel dual-echo ultra-short echo time (DUTE) MR sequence was proposed for head imaging. Simultaneous MR-PET data were acquired and the PET images reconstructed using the proposed MR-DUTE-based AC method were compared with the PET images reconstructed using a CT-based AC. Results Our data suggest that incorrectly accounting for the bone tissue attenuation can lead to large underestimations (>20%) of the radiotracer concentration in the cortex. Assigning a linear attenuation coefficient of 0.143 or 0.151 cm−1 to bone tissue appears to give the best trade-off between bias and variability in the resulting images. Not identifying the internal air cavities introduces large overestimations (>20%) in adjacent structures. Based on these results, the segmented CT AC method was established as the “silver standard” for the segmented MR-based AC method. Particular to an integrated MR-PET scanner, ignoring the RF coil attenuation can cause large underestimations (i.e. up to 50%) in the reconstructed images. Furthermore, the coil location in the PET field of view has to be accurately known. Good quality bone/air segmentation can be performed using the DUTE data. The PET images obtained using the MR-DUTE- and CT-based AC methods compare favorably in most of the brain structures. Conclusion An MR-DUTE-based AC

  1. Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype.

    Science.gov (United States)

    Catana, Ciprian; van der Kouwe, Andre; Benner, Thomas; Michel, Christian J; Hamm, Michael; Fenchel, Matthias; Fischl, Bruce; Rosen, Bruce; Schmand, Matthias; Sorensen, A Gregory

    2010-09-01

    Several factors have to be considered for implementing an accurate attenuation-correction (AC) method in a combined MR-PET scanner. In this work, some of these challenges were investigated, and an AC method based entirely on the MRI data obtained with a single dedicated sequence was developed and used for neurologic studies performed with the MR-PET human brain scanner prototype. The focus was on the problem of bone-air segmentation, selection of the linear attenuation coefficient for bone, and positioning of the radiofrequency coil. The impact of these factors on PET data quantification was studied in simulations and experimental measurements performed on the combined MR-PET scanner. A novel dual-echo ultrashort echo time (DUTE) MRI sequence was proposed for head imaging. Simultaneous MR-PET data were acquired, and the PET images reconstructed using the proposed DUTE MRI-based AC method were compared with the PET images that had been reconstructed using a CT-based AC method. Our data suggest that incorrectly accounting for the bone tissue attenuation can lead to large underestimations (>20%) of the radiotracer concentration in the cortex. Assigning a linear attenuation coefficient of 0.143 or 0.151 cm(-1) to bone tissue appears to give the best trade-off between bias and variability in the resulting images. Not identifying the internal air cavities introduces large overestimations (>20%) in adjacent structures. On the basis of these results, the segmented CT AC method was established as the silver standard for the segmented MRI-based AC method. For an integrated MR-PET scanner, in particular, ignoring the radiofrequency coil attenuation can cause large underestimations (i.e., PET field of view has to be accurately known. High-quality bone-air segmentation can be performed using the DUTE data. The PET images obtained using the DUTE MRI- and CT-based AC methods compare favorably in most of

  2. Clinical value of FDG hybrid-PET in staging and restaging of malignant lymphoma. Compared with conventional diagnostic methods

    International Nuclear Information System (INIS)

    Pichler, R.; Maschek, W.; Hatzl-Griesenhofer, M.; Huber, H.; Wimmer, G.; Wahl, G.; Fridrik, M.

    2000-01-01

    Aim of the present retrospective study was to validate the clinical value of F-18-FDG PET imaging in lymphoma patients with a dual head camera modified for coincidence detection. Staging before and after oncological treatment was compared with a conservative diagnostic approach. Methods: 48 patients (28 non-Hodgkin lymphoma, 20 Hodgkin's disease) received FDG-Hybrid-PET scans. Pretherapeutic staging was realized in 28 patients, 9 of them had control studies after they had completed therapy. Totally 29 persons were examined for posttherapeutic restaging. Computed tomography imaging and lymph node sonography was performed in all cases. Results were validated by clinical follow-up, in three cases a recidive was proven by biopsy. Results: CT and ultrasound detected 77 lesions in 28 patients compared with 100 visualized by PET, but this difference in pretherapeutic staging did not reach significance at p>0.05 by Fisher's t-test. Hybrid-PET obtained a sensitivity of 93%, a specifity of 79%, a positive of 82% and a negative predictive value of 92% for detection of residual disease. The values for CT+US were 87%, 64%, 72% and 88% respectively. Conclusion: FDG Hybrid-PET is as or even more accurate than standard morphologic diagnostic methods for prestaging in malignant lymphoma. Additionally, there is a substancial benefit for therapy monitoring of residual disease using coincidence detection PET with a 3/4-inch crystal gamma camera. (orig.) [de

  3. Cervical SPECT Camera for Parathyroid Imaging

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2012-08-31

    Primary hyperparathyroidism characterized by one or more enlarged parathyroid glands has become one of the most common endocrine diseases in the world affecting about 1 per 1000 in the United States. Standard treatment is highly invasive exploratory neck surgery called Parathyroidectomy. The surgery has a notable mortality rate because of the close proximity to vital structures. The move to minimally invasive parathyroidectomy is hampered by the lack of high resolution pre-surgical imaging techniques that can accurately localize the parathyroid with respect to surrounding structures. We propose to develop a dedicated ultra-high resolution (~ 1 mm) and high sensitivity (10x conventional camera) cervical scintigraphic imaging device. It will be based on a multiple pinhole-camera SPECT system comprising a novel solid state CZT detector that offers the required performance. The overall system will be configured to fit around the neck and comfortably image a patient.

  4. A survey of PET activity in Germany during 1999

    International Nuclear Information System (INIS)

    Brix, Gunnar; Nosske, Dietmar; Minkov, Vladimir; Glatting, Gerhard; Reske, Sven N.

    2002-01-01

    Positron emission tomography (PET) is the most powerful molecular imaging technique currently available for clinical use. The aim of this study was to provide public health information on PET procedures carried out in Germany - a country with a very high number of PET installations. To this end, all facilities that in 1999 were running at least one dedicated PET system were contacted and requested to provide information in a questionnaire on the radiopharmaceuticals applied, the total number and age distribution of patients and volunteers examined, the main diagnostic applications and the range of administered activities. Based on the information provided by 48 of the 60 PET facilities in Germany, an annual frequency of about 0.34 PET procedures per 1,000 inhabitants was estimated, associated with an annual per capita effective dose of about 1.9 μSv. Averaged over all PET procedures, the mean effective dose to patients was 5.6 mSv. The age distribution of patients and volunteers was skewed markedly towards higher ages; only a very small fraction ( 18 F]fluoro-2-deoxy-D-glucose (FDG), which was utilised in more than 84% of all PET procedures. For this tracer, the median value for activities applied for examinations in the three-dimensional (3D) acquisition mode was only half of that used for two-dimensional (2D) measurements. Based on a statistical analysis of the distribution of mean FDG activities administered to patients in the 48 PET facilities who responded to our inquiry, diagnostic reference levels of 370 and 200 MBq are proposed for the 2D and the 3D mode, respectively. (orig.)

  5. Electronics for a prototype variable field of view PET camera using the PMT-quadrant-sharing detector array

    Science.gov (United States)

    Li, H.; Wong, Wai-Hoi; Zhang, N.; Wang, J.; Uribe, J.; Baghaei, H.; Yokoyama, S.

    1999-06-01

    Electronics for a prototype high-resolution PET camera with eight position-sensitive detector modules has been developed. Each module has 16 BGO (Bi/sub 4/Ge/sub 3/O/sub 12/) blocks (each block is composed of 49 crystals). The design goals are component and space reduction. The electronics is composed of five parts: front-end analog processing, digital position decoding, fast timing, coincidence processing and master data acquisition. The front-end analog circuit is a zone-based structure (each zone has 3/spl times/3 PMTs). Nine ADCs digitize integration signals of an active zone identified by eight trigger clusters; each cluster is composed of six photomultiplier tubes (PMTs). A trigger corresponding to a gamma ray is sent to a fast timing board to obtain a time-mark, and the nine digitized signals are passed to the position decoding board, where a real block (four PMTs) can be picked out from the zone for position decoding. Lookup tables are used for energy discrimination and to identify the gamma-hit crystal location. The coincidence board opens a 70-ns initial timing window, followed by two 20-ns true/accidental time-mark lookup table windows. The data output from the coincidence board can be acquired either in sinogram mode or in list mode with a Motorola/IRONICS VME-based system.

  6. The guideline for in-hospital manufactured FDG for PET examinations

    International Nuclear Information System (INIS)

    2001-01-01

    The guideline made by the three working groups of Japan Society of Nuclear Medicine, of subcommittee on Medical Application of Cyclotron-Produced Radionuclides in Medical and Pharmaceutical Science Committee of Japan Radioisotope Association (JRA) and of Radiopharmaceuticals Committee of JRA, deals with working environment and management system of FDG ( 18 F-2-deoxy-2-fluoro-D-glucose) manufacturing, standards for FDG synthetic equipment and its installation, quality and methods of synthesis and assay, PET apparatus and clinical application, for the purpose of safe and effective use of the FDG made in-hospital for its future application into public health insurance. FDG is synthesized in-hospital from 18 F generated from either 20 Ne irradiated by deuteron or 18 O, by proton. For the confirmation in the quality standard, the peaks only at 511 and 1022 keV should be observed by gamma-spectrometry with the half life of 105-115 min. The PET apparatus usable must be a defined one in the Pharmaceutical Affairs Law like that for positron CT, positron camera and PET camera. In clinical application, FDG is formulated for injection and used for examinations of brain/myocardium and cerebral/myocardial glucose consumption, of tumor and tumor FDG uptake and so on. Precautions involve general contraindications and usage in pregnancy, aged people and infants. (K.H.)

  7. A triple GEM gamma camera for medical application

    Energy Technology Data Exchange (ETDEWEB)

    Anulli, F. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Balla, A. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Bencivenni, G. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Corradi, G. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); D' Ambrosio, C. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Domenici, D. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Felici, G. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Gatta, M. [Laboratori Nazionali di Frascati INFN, Frascati (Italy); Morone, M.C. [Dipartimento di Biopatologia e Diagnostica per immagini, Universita di Roma Tor Vergata (Italy); INFN - Sezione di Roma Tor Vergata (Italy); Murtas, F. [Laboratori Nazionali di Frascati INFN, Frascati (Italy)]. E-mail: fabrizio.murtas@lnf.infn.it; Schillaci, O. [Dipartimento di Biopatologia e Diagnostica per immagini, Universita di Roma Tor Vergata (Italy)

    2007-03-01

    A Gamma Camera for medical applications 10x10cm{sup 2} has been built using a triple GEM chamber prototype. The photon converters placed in front of the three GEM foils, has been realized with different technologies. The chamber, High Voltage supplied with a new active divider made in Frascati, is readout through 64 pads, 1mm{sup 2} wide, organized in a row of 8cm long, with LHCb ASDQ chip. This Gamma Camera can be used both for X-ray movie and PET-SPECT imaging; this chamber prototype is placed in a scanner system, creating images of 8x8cm{sup 2}. Several measurements have been performed using phantom and radioactive sources of Tc99m(140keV) and Na22(511keV). Results on spatial resolution and image reconstruction are presented.

  8. Evaluation of list-mode ordered subset expectation maximization image reconstruction for pixelated solid-state compton gamma camera with large number of channels

    Science.gov (United States)

    Kolstein, M.; De Lorenzo, G.; Chmeissani, M.

    2014-04-01

    The Voxel Imaging PET (VIP) Pathfinder project intends to show the advantages of using pixelated solid-state technology for nuclear medicine applications. It proposes designs for Positron Emission Tomography (PET), Positron Emission Mammography (PEM) and Compton gamma camera detectors with a large number of signal channels (of the order of 106). For Compton camera, especially with a large number of readout channels, image reconstruction presents a big challenge. In this work, results are presented for the List-Mode Ordered Subset Expectation Maximization (LM-OSEM) image reconstruction algorithm on simulated data with the VIP Compton camera design. For the simulation, all realistic contributions to the spatial resolution are taken into account, including the Doppler broadening effect. The results show that even with a straightforward implementation of LM-OSEM, good images can be obtained for the proposed Compton camera design. Results are shown for various phantoms, including extended sources and with a distance between the field of view and the first detector plane equal to 100 mm which corresponds to a realistic nuclear medicine environment.

  9. SiPM arrays and miniaturized readout electronics for compact gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Dinu, N., E-mail: dinu@lal.in2p3.fr [Laboratory of Linear Accelerator, IN2P3, CNRS, Orsay (France); Imando, T. Ait; Nagai, A. [Laboratory of Linear Accelerator, IN2P3, CNRS, Orsay (France); Pinot, L. [Laboratory of Imaging and Modelisation in Neurobiology and Cancerology, IN2P3, CNRS, Orsay (France); Puill, V. [Laboratory of Linear Accelerator, IN2P3, CNRS, Orsay (France); Callier, S. [Omega Microelectronics Group, CNRS, Palaiseau (France); Janvier, B.; Esnault, C.; Verdier, M.-A. [Laboratory of Imaging and Modelisation in Neurobiology and Cancerology, IN2P3, CNRS, Orsay (France); Raux, L. [Omega Microelectronics Group, CNRS, Palaiseau (France); Vandenbussche, V.; Charon, Y.; Menard, L. [Laboratory of Imaging and Modelisation in Neurobiology and Cancerology, IN2P3, CNRS, Orsay (France)

    2015-07-01

    This article reports on the design and features of a very compact and light gamma camera based on SiPM arrays and miniaturized readout electronics dedicated to tumor localization during radio-guided cancer surgery. This gamma camera, called MAGICS, is composed of four (2×2) photo-detection elementary modules coupled to an inorganic scintillator. The 256 channels photo-detection system covers a sensitive area of 54×53 m{sup 2}. Each elementary module is based on four (2×2) SiPM monolithic arrays, each array consisting of 16 SiPM photo-sensors (4×4) with 3×3 mm{sup 2} sensitive area, coupled to a miniaturized readout electronics and a dedicated ASIC. The overall dimensions of the electronics fit the size of the detector, enabling to assemble side-by-side several elementary modules in a close-packed arrangement. The preliminary performances of the system are very encouraging, showing an energy resolution of 9.8% and a spatial resolution of less than 1 mm at 122 keV.

  10. Experience with PET FDG - Preliminary analysis

    International Nuclear Information System (INIS)

    Massardo, Teresa; Jofre, Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Galaz, Rodrigo; Miranda, Karina

    2004-01-01

    Full text: The objective of this preliminary communication was to analyse the indications and data in initial group of patients studied with first dedicated PET scanner in the country at Hospital Militar in Santiago Chile. The main application of positron emission tomography (PET) with 18-Fluoro deoxyglucose (FDG) is related with oncological patients management. We studied 136 patients, 131 (97%) with known or suspected malignant disease and remaining 5 for cardiological or neuropsychiatric disease. Ten patients were controlled diabetics (1 insulin dependent). Their mean age was 51.6±18 years ranging from 6 to 84 years and 65% were females. A total of 177 scans were acquired using a dedicated PET (Siemens HR + with 4mm resolution) system. Mean F18-FDG injected dose was 477±107 MBq (12.9±2.9 mCi). Mean blood glucose levels, performed prior the injection, were 94±17mg/dl (range 62-161). F18-FDG was obtained from the cyclotron IBA Cyclone 18/9 installed in the Chilean Agency of Nuclear Energy, distant about 15 miles away from the clinical PET facility. PET studies were analyzed by at least 4 independent observers visually. Standardized uptake value (SUV) was calculated in some cases. Image fusion of FDG images with recent anatomical (CT, MRI) studies was performed where available. Data acquisition protocol consisted in 7-8 beds/study from head to mid-thighs, with 6-7-min/bed acquisitions, 36% transmission with germanium 68 rods. Data was reconstructed with standard OSEM protocol. The main indications included pulmonary lesions in 31%, gastrointestinal cancers in 21%, melanoma in 13% and lymphoma in 9% patients. The remaining were of breast, thyroid, testes, ovary, musculoskeletal (soft tissue and bone), brain tumour etc. Abnormal focal tracer uptake was observed in 83/131 oncological patients, 54% corroborating with clinical diagnosis of primary tumor or recurrence while 46% showed new metastatic localization. FDG scans were normal 36/131 patients. In 9 patients

  11. Experience with PET FDG - Preliminary analysis

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa; Jofre, Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Galaz, Rodrigo; Miranda, Karina [Centro PET de Imagenes Moleculares, Hospital Militar de Santiago, Santiago (Chile)

    2004-01-01

    Full text: The objective of this preliminary communication was to analyse the indications and data in initial group of patients studied with first dedicated PET scanner in the country at Hospital Militar in Santiago Chile. The main application of positron emission tomography (PET) with 18-Fluoro deoxyglucose (FDG) is related with oncological patients management. We studied 136 patients, 131 (97%) with known or suspected malignant disease and remaining 5 for cardiological or neuropsychiatric disease. Ten patients were controlled diabetics (1 insulin dependent). Their mean age was 51.6{+-}18 years ranging from 6 to 84 years and 65% were females. A total of 177 scans were acquired using a dedicated PET (Siemens HR + with 4mm resolution) system. Mean F18-FDG injected dose was 477{+-}107 MBq (12.9{+-}2.9 mCi). Mean blood glucose levels, performed prior the injection, were 94{+-}17mg/dl (range 62-161). F18-FDG was obtained from the cyclotron IBA Cyclone 18/9 installed in the Chilean Agency of Nuclear Energy, distant about 15 miles away from the clinical PET facility. PET studies were analyzed by at least 4 independent observers visually. Standardized uptake value (SUV) was calculated in some cases. Image fusion of FDG images with recent anatomical (CT, MRI) studies was performed where available. Data acquisition protocol consisted in 7-8 beds/study from head to mid-thighs, with 6-7-min/bed acquisitions, 36% transmission with germanium 68 rods. Data was reconstructed with standard OSEM protocol. The main indications included pulmonary lesions in 31%, gastrointestinal cancers in 21%, melanoma in 13% and lymphoma in 9% patients. The remaining were of breast, thyroid, testes, ovary, musculoskeletal (soft tissue and bone), brain tumour etc. Abnormal focal tracer uptake was observed in 83/131 oncological patients, 54% corroborating with clinical diagnosis of primary tumor or recurrence while 46% showed new metastatic localization. FDG scans were normal 36/131 patients. In 9

  12. A real-time monitoring study of the personal dose received by a nuclear medicine technologist (NMT)administering FDG in a high patient throughout PET centre

    International Nuclear Information System (INIS)

    Wallace, A.; Hickson, K.; Bradley, J.

    2007-01-01

    Full text: With the increasing success and developing applications of PET-CT, especially in relation to Oncology I Staging, il is possible thai the number of PET scans may overtake traditional gamma camera scanning as the major scanning I procedure. This rapid growth in PET studies has already resulted in an increasing radiation exposure cost to NMT'. Previous I personnel dosimetry surveys by our group have established the increasing dose impacts of PET and PET-CT investigations Bo staff (7, 2).

  13. PET radiation exposure control for nurses

    International Nuclear Information System (INIS)

    Kawabata, Yumiko; Kikuta, Daisuke; Anzai, Taku

    2005-01-01

    Recently, the number of clinical PET centers is increasing all over Japan. For this reason, the monitoring and control of radiation exposure of employees, especially nurses, in PET-dedicated clinics and institutions are becoming very important issues for their health. We measured the radiation exposure doses of the nurses working at Nishidai Diagnostic Imaging Center, and analyzed the exposure data obtained from them. The exposure doses of the nurses were found to be 4.8 to 7.1 mSv between April 2003 and March 2004. We found that the nurses were mostly exposed to radiation when they had to have contact with patients received an FDG injection or they had trouble with the FDG automatic injection system. To keep radiation exposure of nurses to a minimum we reconfirmed that a proper application of the three principles of protection against radiation exposure was vital. (author)

  14. Hybrid imaging for detection of carcinoma of unknown primary: A preliminary comparison trial of whole-body PET/MRI versus PET/CT

    International Nuclear Information System (INIS)

    Ruhlmann, Verena; Ruhlmann, Marcus; Bellendorf, Alexander; Grueneisen, Johannes; Sawicki, Lino M.; Grafe, Hong; Forsting, Michael; Bockisch, Andreas; Umutlu, Lale

    2016-01-01

    Highlights: • Both 18F-FDG PET/CT and 18F-FDG PET/MRI provide a comparable diagnostic ability for detection of primary cancer and metastases in CUP-syndrome. • Both imaging methods showed comparably high lesion conspicuity and diagnostic confidence (superior assessment of cervical lesions in PET/MRI). • PET/MRI may serve as a powerful alternative, particularly for therapy monitoring or surveillance considering the long-term cumulative dose. - Abstract: Purpose: The aim of this study is to evaluate and compare the diagnostic potential of integrated whole-body [18F]FDG-PET/MRI to [18F]FDG-PET/CT for detection of a potential primary cancer and metastases in patients suspected for cancer of unknown primary (CUP). Methods: A total of 20 patients (15 male, 5 female, age 53 ± 13 years) suspect for CUP underwent a dedicated head and neck & whole-body [18F]FDG-PET/CT (Biograph mCT 128, Siemens Healthcare) and a subsequent simultaneous [18F]FDG-PET/MRI examination (Biograph mMR, Siemens Healthcare). Two readers rated the datasets (PET/CT; PET/MRI) regarding the detection of the primary cancer and metastases, lesion conspicuity (4-point ordinal scale) and diagnostic confidence (3-point ordinal scale). PET analysis comprised the assessment of maximum standardized uptake values (SUVmax) of all PET-positive lesions using volume of interest (VOI) analysis derived from the PET/CT and PET/MR datasets. All available data considering histology and imaging including prior and clinical follow-up examinations served as reference standard. Statistical analysis included comparison of mean values using Mann-Whitney U test and correlation of SUVmax using Pearson‘s correlation. Results: In 14 out of 20 patients 49 malignant lesions were present. The primary cancer could be correctly identified in 11/20 patients with both PET/CT and PET/MRI. PET/CT enabled the detection of a total 38 metastases, PET/MR respectively of 37 metastases (one lung metastasis <5mm was missed). PET/CT and

  15. Hybrid imaging for detection of carcinoma of unknown primary: A preliminary comparison trial of whole-body PET/MRI versus PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Ruhlmann, Verena; Ruhlmann, Marcus; Bellendorf, Alexander [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Grueneisen, Johannes [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Sawicki, Lino M. [Department of Diagnostic and Interventional Radiology, University of Dusseldorf, Moorenstraße 5, 40225 Dusseldorf (Germany); Grafe, Hong [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Forsting, Michael [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Bockisch, Andreas [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Umutlu, Lale, E-mail: verena.ruhlmann@uk-essen.de [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany)

    2016-11-15

    Highlights: • Both 18F-FDG PET/CT and 18F-FDG PET/MRI provide a comparable diagnostic ability for detection of primary cancer and metastases in CUP-syndrome. • Both imaging methods showed comparably high lesion conspicuity and diagnostic confidence (superior assessment of cervical lesions in PET/MRI). • PET/MRI may serve as a powerful alternative, particularly for therapy monitoring or surveillance considering the long-term cumulative dose. - Abstract: Purpose: The aim of this study is to evaluate and compare the diagnostic potential of integrated whole-body [18F]FDG-PET/MRI to [18F]FDG-PET/CT for detection of a potential primary cancer and metastases in patients suspected for cancer of unknown primary (CUP). Methods: A total of 20 patients (15 male, 5 female, age 53 ± 13 years) suspect for CUP underwent a dedicated head and neck & whole-body [18F]FDG-PET/CT (Biograph mCT 128, Siemens Healthcare) and a subsequent simultaneous [18F]FDG-PET/MRI examination (Biograph mMR, Siemens Healthcare). Two readers rated the datasets (PET/CT; PET/MRI) regarding the detection of the primary cancer and metastases, lesion conspicuity (4-point ordinal scale) and diagnostic confidence (3-point ordinal scale). PET analysis comprised the assessment of maximum standardized uptake values (SUVmax) of all PET-positive lesions using volume of interest (VOI) analysis derived from the PET/CT and PET/MR datasets. All available data considering histology and imaging including prior and clinical follow-up examinations served as reference standard. Statistical analysis included comparison of mean values using Mann-Whitney U test and correlation of SUVmax using Pearson‘s correlation. Results: In 14 out of 20 patients 49 malignant lesions were present. The primary cancer could be correctly identified in 11/20 patients with both PET/CT and PET/MRI. PET/CT enabled the detection of a total 38 metastases, PET/MR respectively of 37 metastases (one lung metastasis <5mm was missed). PET/CT and

  16. A fast preamplifier concept for SiPM-based time-of-flight PET detectors

    NARCIS (Netherlands)

    Huizenga, J.; Seifert, S.; Schreuder, F.; Dendooven, P.; Löhner, H.; Vinke, R.; Schaart, D. R.; van Dam, H.T.

    2012-01-01

    Silicon photomultipliers (SiPMs) offer high gain and fast response to light, making them interesting for fast timing applications such as time-of-flight (TOF) PET. To fully exploit the potential of these photosensors, dedicated preamplifiers that do not deteriorate the rise time and signal-to-noise

  17. Development of a simple photon emission computed tomography dedicated to the small animal

    International Nuclear Information System (INIS)

    Bekaert, V.

    2006-11-01

    The development of in vivo small animal imaging becomes essential to study human pathologies. The ImaBio project of Institut Pluridisciplinaire Hubert Curien (IPHC) fits in the process of developing new instruments for biomedical applications with the development of a multimodality imaging platform dedicated to small animal imaging (AMISSA). This thesis presents the study, the design and the development of a Single Photon Emission Computed Tomography (SPECT) which will be integrated to the AMISSA platform. The result of these developments is the possibility to obtain the spatial distribution of an injected molecule into the animal. The SPECT technical solutions are based on the acquired knowledge of the institute allowing the conception of a device with cameras adapted to the gamma detection produced by the radiotracers used in single photon imaging. In order to cover the entire of the transverse field of view, four gamma cameras are arranged in a ring around the volume of interest. Each camera consists of 5 individual modules based on a YAP:Ce crystal array, a multi-anode photomultiplier and a dedicated multichannel electronic device. Finally, 20 detection modules were calibrated to give the same result for an identical energy deposit. The data are acquired then process to extract the positions and the energies deposited by gamma photons in the crystals. This last information is then gathered to build the projections. The 3D reconstructed image from the projections is carried out by the sequence of two algorithms, analytical and iterative OS-EM, both modified to take into account the singular geometry of our detection system. Finally, the obtained image is fused with the anatomical information given by the micro Computed Tomography system. (author)

  18. Solitary pulmonary nodules: accuracy and cost-effectiveness of sodium iodide FDG-PET using Australian data

    International Nuclear Information System (INIS)

    Keith, C.J.; Miles, K.A.; Griffiths, M.R.; Wong, D.; Pitman, A.G.; Hicks, R.J.

    2002-01-01

    This study uses Australian data to confirm the accuracy of dedicated sodium iodide (NaI) fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) in evaluating indeterminate solitary pulmonary nodules (SPNs) and to determine the conditions under which PET could play a cost-effective role in this evaluation. Ninety-two patients from two Australian hospitals in different states underwent FDG-PET for evaluation of an SPN. Observed values for prior probability of malignancy and diagnostic accuracy of PET were applied to previously published decision tree models using published Australian health care costs. The accuracy of FDG-PET was 93% with a sensitivity of 92% and a specificity of 95%. The prior probability of malignancy (0.54), PET sensitivity and PET specificity indicated cost savings per patient of up to EUR 455 (A$ 774) based on a PET cost of EUR 706 (A$ 1,200). PET would remain cost-effective for levels of prior probability up to 0.8-0.9 and a PET cost of EUR 736-1,161 (A$ 1,252-A$ 1,974). It is concluded that NaI PET is accurate, cost saving and cost-effective for the characterisation of indeterminate pulmonary nodules in Australia. Comparison with previous reports from the United States confirms that FDG-PET can remain cost-effective despite population differences in medical costs, disease prevalence and PET diagnostic performance. (orig.)

  19. Determination of position and shape of flexible mri surface coils using the Microsoft Kinect for attenuation correction in PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Frohwein, Lynn; He, Mirco; Buther, Florian; Safers, Klaus [European Institute for Molecular Imaging, University of Muenster (Germany)

    2015-05-18

    Due to the varying position and shape of flexible MRI RF surface coils, the creation of attenuation maps for these coils is a challenging task. Nevertheless, coil material (metal, plastic, rubber) attenuates the PET signal to a considerable amount. Thus, including a coil μ-map into the human μ-map is essential. In this work, we present a method to determine the position and shape of flexible coils with the help of the Microsoft Kinect depth camera. Phantom PET/MRI (Siemens Biograph mMR) and CT scans (Siemens Biograph mCT) were performed with and without the flexible 32-channel coil equipped with 15 markers visible in CT and Kinect. Prior to the PET/MRI acquisition, Kinect data is acquired of the phantom with the coil on top. The manually extracted marker positions from CT and Kinect are used to non-rigidly transform the template CT according to the Kinect marker positions describing the shape of the coil during PET/MRI acquisition. An appropriate μ-map can then be calculated from the transformed CT dataset. Subsequently, the μ-map is placed in relation to the patient table according to the Kinect-derived marker positions. First results show that the coil shape can be determined with the help of the Kinect camera. The transformation of the template CT dataset according to Kinect marker positions during PET/MRI leads to appropriate results. Furthermore, the position of the coil can also be determined for an accurate placement of the μ-map in relation to the patient table. The determination of position and shape of flexible surface coils using the Kinect camera can be a way to include the CT-based coil μ-map in PET/MRI acquisitions without the need for additional MRI scans. Accuracy and practicability of the method have to be tested in further experiments.

  20. Determination of position and shape of flexible mri surface coils using the Microsoft Kinect for attenuation correction in PET/MRI

    International Nuclear Information System (INIS)

    Frohwein, Lynn; He, Mirco; Buther, Florian; Safers, Klaus

    2015-01-01

    Due to the varying position and shape of flexible MRI RF surface coils, the creation of attenuation maps for these coils is a challenging task. Nevertheless, coil material (metal, plastic, rubber) attenuates the PET signal to a considerable amount. Thus, including a coil μ-map into the human μ-map is essential. In this work, we present a method to determine the position and shape of flexible coils with the help of the Microsoft Kinect depth camera. Phantom PET/MRI (Siemens Biograph mMR) and CT scans (Siemens Biograph mCT) were performed with and without the flexible 32-channel coil equipped with 15 markers visible in CT and Kinect. Prior to the PET/MRI acquisition, Kinect data is acquired of the phantom with the coil on top. The manually extracted marker positions from CT and Kinect are used to non-rigidly transform the template CT according to the Kinect marker positions describing the shape of the coil during PET/MRI acquisition. An appropriate μ-map can then be calculated from the transformed CT dataset. Subsequently, the μ-map is placed in relation to the patient table according to the Kinect-derived marker positions. First results show that the coil shape can be determined with the help of the Kinect camera. The transformation of the template CT dataset according to Kinect marker positions during PET/MRI leads to appropriate results. Furthermore, the position of the coil can also be determined for an accurate placement of the μ-map in relation to the patient table. The determination of position and shape of flexible surface coils using the Kinect camera can be a way to include the CT-based coil μ-map in PET/MRI acquisitions without the need for additional MRI scans. Accuracy and practicability of the method have to be tested in further experiments.

  1. A PET Prototype for “In-Beam” Monitoring of Proton Therapy

    Science.gov (United States)

    Vecchio, Sara; Attanasi, Francesca; Belcari, Nicola; Camarda, Manuela; Cirrone, G. A. Pablo; Cuttone, Giacomo; Di Rosa, Francesco; Lanconelli, Nico; Moehrs, Sascha; Rosso, Valeria; Russo, Giorgio; Del Guerra, Alberto

    2009-02-01

    The in-beam PET is a novel PET application to image the beta+ activity induced in biological tissues by hadronic therapeutic beams. Thanks to the correlation existing between beam-delivered dose profiles and beam-induced activity profiles, in vivo information about the effective ion paths can be extracted from the in-beam pet image. in situ measurements, immediately after patient irradiation, are recommended in order to exploit the maximum statistics, by also detecting the contribution provided by the very short lived isotopes, e.g. 15O. A compact, dedicated tomograph should then be developed for such an application, so as to be used in the treatment room. We developed a small PET prototype in order to demonstrate the feasibility of such a technique for the monitoring of proton therapy of ocular tumors at the CATANA facility (Catania, Italy). The prototype consists of two planar heads with an active area of about 5 cm times 5 cm. Each head is made up of a square position sensitive photomultiplier (Hamamatsu H8500) coupled to a matrix of the same size of LYSO scintillating crystals (2 mm times 2 mm times 18 mm pixel dimensions). Dedicated, compact electronic boards are used for the signal multiplexing, amplification and digitization. The distance between the pair can be varied from 10 cm up to a maximum of about 20 cm. The validation of the prototype was performed on plastic phantoms using 62 MeV protons at the CATANA beam line. Different dose distributions were delivered and a good correlation between the distal fall-off of the activity profiles and of the dose profiles was found, i.e., better than 2 mm along the beam direction.

  2. Combined PET/MR: The Real Work Has Just Started. Summary Report of the Third International Workshop on PET/MR Imaging; February 17-21, 2014, Tübingen, Germany.

    Science.gov (United States)

    Bailey, D L; Antoch, G; Bartenstein, P; Barthel, H; Beer, A J; Bisdas, S; Bluemke, D A; Boellaard, R; Claussen, C D; Franzius, C; Hacker, M; Hricak, H; la Fougère, C; Gückel, B; Nekolla, S G; Pichler, B J; Purz, S; Quick, H H; Sabri, O; Sattler, B; Schäfer, J; Schmidt, H; van den Hoff, J; Voss, S; Weber, W; Wehrl, H F; Beyer, T

    2015-06-01

    This paper summarises the proceedings and discussions at the third annual workshop held in Tübingen, Germany, dedicated to the advancement of the technical, scientific and clinical applications of combined PET/MRI systems in humans. Two days of basic scientific and technical instructions with "hands-on" tutorials were followed by 3 days of invited presentations from active researchers in this and associated fields augmented by round-table discussions and dialogue boards with specific themes. These included the use of PET/MRI in paediatric oncology and in adult neurology, oncology and cardiology, the development of multi-parametric analyses, and efforts to standardise PET/MRI examinations to allow pooling of data for evaluating the technology. A poll taken on the final day demonstrated that over 50 % of those present felt that while PET/MRI technology underwent an inevitable slump after its much-anticipated initial launch, it was now entering a period of slow, progressive development, with new key applications emerging. In particular, researchers are focusing on exploiting the complementary nature of the physiological (PET) and biochemical (MRI/MRS) data within the morphological framework (MRI) that these devices can provide. Much of the discussion was summed up on the final day when one speaker commented on the state of PET/MRI: "the real work has just started".

  3. Markerless 3D Head Tracking for Motion Correction in High Resolution PET Brain Imaging

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter

    relying on markers. Data-driven motion correction is problematic due to the physiological dynamics. Marker-based tracking is potentially unreliable, and it is extremely hard to validate when the tracking information is correct. The motion estimation is essential for proper motion correction of the PET......This thesis concerns application specific 3D head tracking. The purpose is to improve motion correction in position emission tomography (PET) brain imaging through development of markerless tracking. Currently, motion correction strategies are based on either the PET data itself or tracking devices...... images. Incorrect motion correction can in the worst cases result in wrong diagnosis or treatment. The evolution of a markerless custom-made structured light 3D surface tracking system is presented. The system is targeted at state-of-the-art high resolution dedicated brain PET scanners with a resolution...

  4. In-beam PET at high-energy photon beams: a feasibility study

    Science.gov (United States)

    Müller, H.; Enghardt, W.

    2006-04-01

    For radiation therapy with carbon ion beams, either for the stable isotope 12C or for the radioactive one 11C, it has been demonstrated that the β+-activity distribution created or deposited, respectively, within the irradiated volume can be visualized by means of positron emission tomography (PET). The PET images provide valuable information for quality assurance and precision improvement of ion therapy. Dedicated PET scanners have been integrated into treatment sites at the Heavy Ion Medical Accelerator at Chiba (HIMAC), Japan, and the Gesellschaft für Schwerionenforschung (GSI), Germany, to make PET imaging feasible during therapeutic irradiation (in-beam PET). A similar technique may be worthwhile for radiotherapy with high-energy bremsstrahlung. In addition to monitoring the dose delivery process which in-beam PET has been primarily developed for, it may be expected that radiation response of tissue can be detected by means of in-beam PET. We investigate the applicability of PET for treatment control in the case of using bremsstrahlung spectra produced by 15-50 MeV electrons. Target volume activation due to (γ, n) reactions at energies above 20 MeV yields moderate β+-activity levels, which can be employed for imaging. The radiation from positrons produced by pair production is not presently usable because the detectors are overloaded due to the low duty factor of medical electron linear accelerators. However, the degradation of images caused by positron motion between creation and annihilation seems to be tolerable.

  5. A simple data loss model for positron camera systems

    International Nuclear Information System (INIS)

    Eriksson, L.; Dahlbom, M.

    1994-01-01

    A simple model to describe data losses in PET cameras is presented. The model is not intended to be used primarily for dead time corrections in existing scanners, although this is possible. Instead the model is intended to be used for data simulations in order to determine the figures of merit of future camera systems, based on data handling state-of-art solutions. The model assumes the data loss to be factorized into two components, one describing the detector or block-detector performance and the other the remaining data handling such as coincidence determinations, data transfer and data storage. Two modern positron camera systems have been investigated in terms of this model. These are the Siemens-CTI ECAT EXACT and ECAT EXACT HR systems, which both have an axial field-of-view (FOV) of about 15 cm. They both have retractable septa and can acquire data from the whole volume within the FOV and can reconstruct volume image data. An example is given how to use the model for live time calculation in a futuristic large axial FOV cylindrical system

  6. Digitized video subject positioning and surveillance system for PET

    International Nuclear Information System (INIS)

    Picard, Y.; Thompson, C.J.

    1995-01-01

    Head motion is a significant contribution to the degradation of image quality of Positron Emission Tomography (PET) studies. Images from different studies must also be realigned digitally to be correlated when the subject position has changed. These constraints could be eliminated if the subject's head position could be monitored accurately. The authors have developed a video camera-based surveillance system to monitor the head position and motion of subjects undergoing PET studies. The system consists of two CCD (charge-coupled device) cameras placed orthogonally such that both face and profile views of the subject's head are displayed side by side on an RGB video monitor. Digitized images overlay the live images in contrasting colors on the monitor. Such a system can be used to (1) position the subject in the field of view (FOV) by displaying the position of the scanner's slices on the monitor along with the current subject position, (2) monitor head motion and alert the operator of any motion during the study and (3) reposition the subject accurately for subsequent studies by displaying the previous position along with the current position in a contrasting color

  7. Study of a new architecture of gamma cameras with Cd/ZnTe/CdTe semiconductors; Etude d'une nouvelle architecture de gamma camera a base de semi-conducteurs CdZnTe /CdTe

    Energy Technology Data Exchange (ETDEWEB)

    Guerin, L

    2007-11-15

    This thesis studies new semi conductors for gammas cameras in order to improve the quality of image in nuclear medicine. The chapter 1 reminds the general principle of the imaging gamma, by describing the radiotracers, the channel of detection and the types of Anger gamma cameras acquisition. The physiological, physical and technological limits of the camera are then highlighted, to better identify the needs of future gamma cameras. The chapter 2 is dedicated to a bibliographical study. At first, semi-conductors used in imaging gamma are presented, and more particularly semi-conductors CDTE and CdZnTe, by distinguishing planar detectors and monolithic pixelated detectors. Secondly, the classic collimators of the gamma cameras, used in clinical routine for the most part of between them, are described. Their geometry is presented, as well as their characteristics, their advantages and their inconveniences. The chapter 3 is dedicated to a state of art of the simulation codes dedicated to the medical imaging and the methods of reconstruction in imaging gamma. These states of art allow to introduce the software of simulation and the methods of reconstruction used within the framework of this thesis. The chapter 4 presents the new architecture of gamma camera proposed during this work of thesis. It is structured in three parts. The first part justifies the use of semiconducting detectors CdZnTe, in particular the monolithic pixelated detectors, by bringing to light their advantages with regard to the detection modules based on scintillator. The second part presents gamma cameras to base of detectors CdZnTe (prototypes or commercial products) and their associated collimators, as well as the interest of an association of detectors CdZnTe in the classic collimators. Finally, the third part presents in detail the HiSens architecture. The chapter 5 describes both software of simulation used within the framework of this thesis to estimate the performances of the Hi

  8. FDG-PET identification of intraperitoneal metastases

    International Nuclear Information System (INIS)

    Gamez, C.; Jimenez-Hoyuelam, J.M.; Rebollo, A.C.; Gonzalez, P.; Rico, J.M.; Alba, E.; Sacchetti, A.; Lopez-Rueda, B.

    2002-01-01

    Aim: Peritoneal metastases (PM) are usually from intra-abdominal primary neoplasms, such as carcinoma of the stomach, colon, ovary, and pancreas, or from intra-abdominal lymphoma. Metastases disseminate throughout the peritoneum in four ways: 1) direct spread along peritoneal ligaments, mesenteries and omenta; 2) via the flow of ascitis fluid. 3) lymphatic extension, and 4) embolic hematogenous spread. Although CT is quite specific in identifying PM it is not very sensitive, and peritoneal lavage or biopsy can be very useful but have sampling errors. This study assessed the clinical value of FDG-PET for the detection of PM of malignant diseases. Materials and Methods: 15 FDG-PET scans of patients referred for recurrence (mean age = 54 y/o, sex = 6M, 9F), with metabolic abnormalities suspicious findings of PM from carcinoma of the colon (7), ovary (3), lymphoma (2), pancreas (1), gastrointestinal stromal tumor (1) and melanoma (1) were reviewed. The whole-body studies were performed 50 min following the intravenous administration of 370 MBq of 18F-FDG, in a high resolution dedicated PET scanner (Advance, GEMS), with images reconstructed using a iterative algorithm with segmented attenuation correction. Visual interpretation and SUV values were correlated with CT/MRI findings and biopsy/follow-up. Results: Of the 15 patients, 7 showed <3 sites of focal uptake and 8 presented multiple foci or a diffuse hypermetabolism in the abdomen (SUVmax3.04-18.83 g/ml). 6 patients had biopsy confirmation by PET-directed surgery (6 proven PM, 0 negative biopsies). 11 FDG-PET scans had correspondence with the CT/MRI findings and 4 showed discrepancies (PET positive-CT/MRI negative in patients with isolated raising tumor markers levels or unsuspected PM). FDG-PET influenced the therapeutic management in 2 patients as presented multiple metastases leading them from surgery to chemotherapy. Conclusion: When used as a complementary imaging tool to the conventional work up, FDG-PET is

  9. WE-AB-204-03: A Novel 3D Printed Phantom for 4D PET/CT Imaging and SIB Radiotherapy Verification

    International Nuclear Information System (INIS)

    Soultan, D; Murphy, J; Moiseenko, V; Cervino, L; Gill, B

    2015-01-01

    Purpose: To construct and test a 3D printed phantom designed to mimic variable PET tracer uptake seen in lung tumor volumes. To assess segmentation accuracy of sub-volumes of the phantom following 4D PET/CT scanning with ideal and patient-specific respiratory motion. To plan, deliver and verify delivery of PET-driven, gated, simultaneous integrated boost (SIB) radiotherapy plans. Methods: A set of phantoms and inserts were designed and manufactured for a realistic representation of lung cancer gated radiotherapy steps from 4D PET/CT scanning to dose delivery. A cylindrical phantom (40x 120 mm) holds inserts for PET/CT scanning. The novel 3D printed insert dedicated to 4D PET/CT mimics high PET tracer uptake in the core and lower uptake in the periphery. This insert is a variable density porous cylinder (22.12×70 mm), ABS-P430 thermoplastic, 3D printed by uPrint SE Plus with inner void volume (5.5×42 mm). The square pores (1.8×1.8 mm2 each) fill 50% of outer volume, resulting in a 2:1 SUV ratio of PET-tracer in the void volume with respect to porous volume. A matching in size cylindrical phantom is dedicated to validate gated radiotherapy. It contains eight peripheral holes matching the location of the porous part of the 3D printed insert, and one central hole. These holes accommodate adaptors for Farmer-type ion chamber and cells vials. Results: End-to-end test were performed from 4D PET/CT scanning to transferring data to the planning system and target volume delineation. 4D PET/CT scans were acquired of the phantom with different respiratory motion patterns and gating windows. A measured 2:1 18F-FDG SUV ratio between inner void and outer volume matched the 3D printed design. Conclusion: The novel 3D printed phantom mimics variable PET tracer uptake typical of tumors. Obtained 4D PET/CT scans are suitable for segmentation, treatment planning and delivery in SIB gated treatments of NSCLC

  10. Prototype of high resolution PET using resistive electrode position sensitive CdTe detectors

    International Nuclear Information System (INIS)

    Kikuchi, Yohei; Ishii, Keizo; Matsuyama, Shigeo; Yamazaki, Hiromichi

    2008-01-01

    Downsizing detector elements makes it possible that spatial resolutions of positron emission tomography (PET) cameras are improved very much. From this point of view, semiconductor detectors are preferable. To obtain high resolution, the pixel type or the multi strip type of semiconductor detectors can be used. However, in this case, there is a low packing ratio problem, because a dead area between detector arrays cannot be neglected. Here, we propose the use of position sensitive semiconductor detectors with resistive electrode. The CdTe detector is promising as a detector for PET camera because of its high sensitivity. In this paper, we report development of prototype of high resolution PET using resistive electrode position sensitive CdTe detectors. We made 1-dimensional position sensitive CdTe detectors experimentally by changing the electrode thickness. We obtained 750 A as an appropriate thickness of position sensitive detectors, and evaluated the performance of the detector using a collimated 241 Am source. A good position resolution of 1.2 mm full width half maximum (FWHM) was obtained. On the basis of the fundamental development of resistive electrode position sensitive detectors, we constructed a prototype of high resolution PET which was a dual head type and was consisted of thirty-two 1-dimensional position sensitive detectors. In conclusion, we obtained high resolutions which are 0.75 mm (FWHM) in transaxial, and 1.5 mm (FWHM) in axial. (author)

  11. Multiparametric evaluation by simultaneous PET-MRI examination in patients with histologically proven laryngeal cancer.

    Science.gov (United States)

    Cavaliere, Carlo; Romeo, Valeria; Aiello, Marco; Mesolella, Massimo; Iorio, Brigida; Barbuto, Luigi; Cantone, Elena; Nicolai, Emanuele; Covello, Mario

    2017-03-01

    To evaluate the relationship between metabolic 18Fluoro-Deoxyglucose-Positron Emission Tomography (18FDG/PET) and morpho-functional parameters derived by Magnetic Resonance Imaging (MRI) in patients with histologically proven laryngeal cancer. To assess the clinical impact of PET/MRI examination on patient's staging and treatment planning. 16 patients with histologically proven laryngeal cancer were enrolled and underwent whole body PET/CT followed by a dedicated PET/MRI of the head/neck region. Data were separately evaluated by two blinded groups: metabolic (SUV and MTV), diffusion (ADC) and perfusion (K trans , V e , k ep and iAUC) maps were obtained by positioning regions of interest (ROIs). Tumoral local extension assessed on PET/MRI was compared to endoscopic findings. A good inter-observer agreement was found in anatomical location and local extension of PET/MRI lesions (Cohen's kappa 0.9). PET/CT SUV measures highly correlate with ones derived by PET/MRI (e.g., p=0.96 for measures on VOI). Significant correlations among metabolic, diffusion and perfusion parameters have been detected. PET/MRI had a relevant clinical impact, confirming endoscopic findings (6 cases), helping treatment planning (9 cases), and modifying endoscopic primary staging (1 case). PET/MRI is useful for primary staging of laryngeal cancer, allowing simultaneous collection of metabolic and functional data and conditioning the therapeutic strategies. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. A scanning point source for quality control of FOV uniformity in GC-PET imaging

    International Nuclear Information System (INIS)

    Bergmann, H.; Minear, G.; Dobrozemsky, G.; Nowotny, R.; Koenig, B.

    2002-01-01

    Aim: PET imaging with coincidence cameras (GC-PET) requires additional quality control procedures to check the function of coincidence circuitry and detector zoning. In particular, the uniformity response over the field of view needs special attention since it is known that coincidence counting mode may suffer from non-uniformity effects not present in single photon mode. Materials and methods: An inexpensive linear scanner with a stepper motor and a digital interface to a PC with software allowing versatile scanning modes was developed. The scanner is used with a source holder containing a Sodium-22 point source. While moving the source along the axis of rotation of the GC-PET system, a tomographic acquisition takes place. The scan covers the full axial field of view of the 2-D or 3-D scatter frame. Depending on the acquisition software, point source scanning takes place continuously while only one projection is acquired or is done in step-and-shoot mode with the number of positions equal to the number of gantry steps. Special software was developed to analyse the resulting list mode acquisition files and to produce an image of the recorded coincidence events of each head. Results: Uniformity images of coincidence events were obtained after further correction for systematic sensitivity variations caused by acquisition geometry. The resulting images are analysed visually and by calculating NEMA uniformity indices as for a planar flood field. The method has been applied successfully to two different brands of GC-PET capable gamma cameras. Conclusion: Uniformity of GC-PET can be tested quickly and accurately with a routine QC procedure, using a Sodium-22 scanning point source and an inexpensive mechanical scanning device. The method can be used for both 2-D and 3-D acquisition modes and fills an important gap in the quality control system for GC-PET

  13. Perfusion CT compared to H{sub 2}{sup 15}O/O{sup 15}O PET in patients with chronic cervical carotid artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Kamath, Amita; Chien, Jeffrey D.; Dillon, William P.; Wintermark, Max [University of California, San Francisco, Department of Radiology, Neuroradiology Section, San Francisco, CA (United States); Smith, Wade S. [University of California, Department of Neurology, San Francisco, CA (United States); Powers, William J. [University of North Carolina, Department of Neurology, Chapel Hill, NC (United States); Cianfoni, Alessandro [Catholic University of Sacred Heart, Department of Bioimages and Radiological Sciences, Rome (Italy); Videen, Tom [Washington University School of Medicine, Departments of Neurology and Radiology, St. Louis, MO (United States); Lawton, Michael T. [University of California, San Francisco, CA (United States). Department of Neurosurgery; Finley, Bruce [Northern California PET Imaging Center, Sacramento, CA (United States)

    2008-09-15

    The purpose of this study was to compare the results of perfusion computed tomography (PCT) with those of {sup 15}O{sub 2}/H{sub 2}{sup 15}O positron emission tomography (PET) in a subset of Carotid Occlusion Surgery Study (COSS) patients. Six patients enrolled in the COSS underwent a standard-of-care PCT in addition to the {sup 15}O{sub 2}/H{sub 2}{sup 15}O PET study used for selection for extracranial-intracranial bypass surgery. PCT and PET studies were coregistered and then processed separately by different radiologists. Relative measurement of cerebral blood flow (CBF) and oxygen extraction fraction (OEF) were calculated from PET. PCT datasets were processed using different arterial input functions (AIF). Relative PCT and PET CBF values from matching regions of interest were compared using linear regression model to determine the most appropriate arterial input function for PCT. Also, PCT measurements using the most accurate AIF were evaluated for linear regression with respect to relative PET OEF values. The most accurate PCT relative CBF maps with respect to the gold standard PET CBF were obtained when CBF values for each arterial territory are calculated using a dedicated AIF for each territory (R{sup 2}=0.796, p<0.001). PCT mean transit time (MTT) is the parameter that showed the best correlation with the count-based PET OEF ratios (R{sup 2}=0.590, p<0.001). PCT relative CBF compares favorably to PET relative CBF in patients with chronic carotid occlusion when processed using a dedicated AIF for each territory. The PCT MTT parameter correlated best with PET relative OEF. (orig.)

  14. Detection and compensation of organ/lesion motion using 4D-PET/CT respiratory gated acquisition techniques

    International Nuclear Information System (INIS)

    Bettinardi, Valentino; Picchio, Maria; Di Muzio, Nadia; Gianolli, Luigi; Gilardi, Maria Carla; Messa, Cristina

    2010-01-01

    Purpose: To describe the degradation effects produced by respiratory organ and lesion motion on PET/CT images and to define the role of respiratory gated (RG) 4D-PET/CT techniques to compensate for such effects. Methods: Based on the literature and on our own experience, technical recommendations and clinical indications for the use of RG 4D PET/CT have been outlined. Results: RG 4D-PET/CT techniques require a state of the art PET/CT scanner, a respiratory monitoring system and dedicated acquisition and processing protocols. Patient training is particularly important to obtain a regular breathing pattern. An adequate number of phases has to be selected to balance motion compensation and statistical noise. RG 4D PET/CT motion free images may be clinically useful for tumour tissue characterization, monitoring patient treatment and target definition in radiation therapy planning. Conclusions: RG 4D PET/CT is a valuable tool to improve image quality and quantitative accuracy and to assess and measure organ and lesion motion for radiotherapy planning.

  15. A contactless approach for respiratory gating in PET using continuous-wave radar.

    Science.gov (United States)

    Ersepke, Thomas; Büther, Florian; Heß, Mirco; Schäfers, Klaus P

    2015-08-01

    Respiratory gating is commonly used to reduce motion artifacts in positron emission tomography (PET). Clinically established methods for respiratory gating in PET require contact to the patient or a direct optical line between the sensor and the patient's torso and time consuming preparation. In this work, a contactless method for capturing a respiratory signal during PET is presented based on continuous-wave radar. The proposed method relies on the principle of emitting an electromagnetic wave and detecting the phase shift of the reflected wave, modulated due to the respiratory movement of the patient's torso. A 24 GHz carrier frequency was chosen allowing wave propagation through plastic and clothing with high reflections at the skin surface. A detector module and signal processing algorithms were developed to extract a quantitative respiratory signal. The sensor was validated using a high precision linear table. During volunteer measurements and [(18)F] FDG PET scans, the radar sensor was positioned inside the scanner bore of a PET/computed tomography scanner. As reference, pressure belt (one volunteer), depth camera-based (two volunteers, two patients), and PET data-driven (six patients) signals were acquired simultaneously and the signal correlation was quantified. The developed system demonstrated a high measurement accuracy for movement detection within the submillimeter range. With the proposed method, small displacements of 25 μm could be detected, not considerably influenced by clothing or blankets. From the patient studies, the extracted respiratory radar signals revealed high correlation (Pearson correlation coefficient) to those derived from the external pressure belt and depth camera signals (r = 0.69-0.99) and moderate correlation to those of the internal data-driven signals (r = 0.53-0.70). In some cases, a cardiac signal could be visualized, due to the representation of the mechanical heart motion on the skin. Accurate respiratory signals were

  16. Construction and tests of an in-beam PET-like demonstrator for hadrontherapy beam ballistic control

    Energy Technology Data Exchange (ETDEWEB)

    Montarou, G., E-mail: montarou@clermont.in2p3.fr [Clermont University, Blaise Pascal University, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, Clermont-Ferrand F-63000 (France); Bony, M.; Busato, E.; Chadelas, R. [Clermont University, Blaise Pascal University, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, Clermont-Ferrand F-63000 (France); Donnarieix, D. [Centre Jean Perrin, Service de Physique Médicale, Clermont-Ferrand F-63000 (France); Force, P.; Guicheney, C.; Insa, C.; Lambert, D.; Lestand, L.; Magne, M.; Martin, F. [Clermont University, Blaise Pascal University, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, Clermont-Ferrand F-63000 (France); Millardet, C. [Centre Jean Perrin, Service de Physique Médicale, Clermont-Ferrand F-63000 (France); Nivoix, M.; Podlyski, F.; Rozes, A. [Clermont University, Blaise Pascal University, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, Clermont-Ferrand F-63000 (France)

    2017-02-11

    We present the first results obtained with a detector, called Large Area Pixelized Detector (LAPD), dedicated to the study the ballistic control of the beam delivered to the patient by in-beam and real time detection of secondary particles, emitted during its irradiation in the context of hadrontherapy. These particles are 511 keV γ from the annihilation of a positron issued from the β{sup +} emitters induced in the patient tissues along the beam path. The LAPD basic concepts are similar to a conventional PET camera. The 511 keV γ are detected and the reconstructed lines of response allow to measure the β{sup +} activity distribution. Nevertheless, when trying to use γ from positron annihilation for the ballistic control in hadrontherapy, the large prompt γ background should be taken into account and properly rejected. First reconstruction results, obtained with a phantom filled with a high intensity FDG source at the cancer research centre of Clermont-Ferrand are shown. We also report results of measurements performed at the Heidelberg Ion-Beam Therapy Centre with one third of the detector, using proton and carbon ion beams.

  17. Design Optimization of a TOF, Breast PET Scanner

    OpenAIRE

    Lee, Eunsin; Werner, Matthew E.; Karp, Joel S.; Surti, Suleman

    2013-01-01

    A dedicated breast positron emission tomography (PET) scanner with limited angle geometry can provide flexibility in detector placement around the patient as well as the ability to combine it with other imaging modalities. A primary challenge of a stationary limited angle scanner is the reduced image quality due to artifacts present in the reconstructed image leading to a loss in quantitative information. Previously it has been shown that using time-of-flight (TOF) information in image recons...

  18. The value of gamma camera and computed tomography data set coregistration to assess Lewis Y antigen targeting in small cell lung cancer by 111Indium-labeled humanized monoclonal antibody 3S193

    International Nuclear Information System (INIS)

    Quaia, Emilio; Krug, Lee M.; Pandit-Taskar, Neeta; Nagel, Andrew; Reuter, Victor E.; Humm, John; Divgi, Chaitanya

    2008-01-01

    Aim: To assess the value of data set coregistration of gamma camera and computed tomography (CT) in the assessment of targeting of humanized monoclonal antibody 3S193 labeled with indium-111 ( 111 In-hu3S193) to small cell lung cancer (SCLC). Methods and materials: Ten patients (6 male and 4 female; mean age ± S.D., 60 ± 4 years), from an overall population of 20 patients with SCLCs expressing Lewis Y antigen at immunohistochemical analysis, completed a four weekly injections of 111 In-hu3S193 and underwent gamma camera imaging. All had had, as part of their baseline evaluation, Fluorine18 fluoro-2-deoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT). Two readers in consensus retrospectively coregistered the gamma camera images with the CT component of the FDG PET/CT by automatic or manual alignment. The resulting image sets were visually examined and SCLC lesions targeting at coregistered gamma camera and CT was correlated side-by-side with the 18 F-FDG uptake. Results: A total number of 31 lesions from SCLC with a thoracic (n = 13) or extrathoracic location (n = 18) were all positive on FDG PET/CT. Coregistration of the gamma camera to the CT demonstrated targeting of antibody to all lesions >2 cm (n = 20) and in a few lesions ≤2 cm (n = 2), with no visualization of most lesions ≤2 cm (n = 9). No 111 In-hu3S193 uptake in normal tissues was observed. Conclusion: Coregistration of antibody gamma camera imaging to FDG PET/CT is feasible and allows valuable assessment of 111 In-hu3S193 antibody targeting to SCLC lesions >2 cm, while lesions ≤2 cm reveal a limited targeting

  19. Automated analysis of PET based in-vivo monitoring in ion beam therapy

    International Nuclear Information System (INIS)

    Kuess, P.

    2014-01-01

    experimental data two dedicated phantoms were irradiated with 12C-beams and subsequently monitored with the in-beam PET prototype at GSI. Additionally these experimental data were used to compare the PCC based algorithm with a range comparison algorithm developed at the TUD Dresden. The lower limit of detecting range uncertainties for H&N patients was 4 mm. The same value was found for the detection of setup uncertainties for H&N cases. Regarding smaller lesions in heterogeneous tissue (e.g. lung) a detection down to 2 mm was possible. A deviation detection in homogeneous tissue (e.g. pelvic area) remained challenging, especially due to very similar tissue components the PT-PET images for such anatomic regions are too much alike. The testing of the PCC based algorithm in dedicated phantoms revealed that a range deviation of 2 mm and more could be detected automatically. Filled cavities could be successfully detected if their diameter was at least 5 mm. The obtained results demonstrated that the automated comparison of BADs provides similar results as visual inspections. The capability of automatically detecting patient setup errors using PT-PET demonstrates the wide applicability of this technique. The investigations performed in different anatomic regions with different tissue compositions demonstrated both the potential and the limitations of PT-PET in general and of the automated evaluation tool in particular. With the design of dedicated phantoms and the subsequent acquired experimental PT-PET data an objective measure is given to test the evaluation software. In conclusion the developed software tool has the potential to reduce the clinical workload essentially so that the implementation of PT-PET in the clinical routine becomes a promising verification option for future PT treatments. Further development of the software tool has to be performed in a clinical environment with the possibility to test the automated comparison for larger cohorts with similar patient

  20. Business administration of PET facilities. A cost analysis of three facilities utilizing delivery FDG

    International Nuclear Information System (INIS)

    Mitsutake, Naohiro; Oku, Shinya; Fujii, Ryo; Furui, Yuji; Yasunaga, Hideo

    2008-01-01

    PET (positron emission tomography) has been proved to be a powerful imaging tool in clinical oncology. The number of PET facilities in Japan has remarkably increased over the last decade. Furthermore, the approval of delivery fluorodeoxyglucose (FDG) in 2005 resulted in a tremendous expansion of the PET institutions without a cyclotron facility. The aim of this study was to conduct a cost analysis of PET institutions that utilized delivery FDG. Three PET facilities using delivery FDG were investigated about the costs for PET service. Fixed costs included depreciation costs for construction and medical equipments such as positron camera. Variable costs consisted of costs for medical materials including delivery FDG. The break-even point was analyzed in each of three institutions. In the three hospitals (A, B and C), the annual number of PET scan was 1,591, 1,637 and 914, while cost per scan was accounted as 110,262 yen, 111,091 yen, and 134,192 yen, respectively. The break-even point was calculated to be 2,583, 2,679 and 2,081, respectively. PET facilities utilizing delivery FDG seemed to have difficulty in business administration. Such a situation suggests the possibility that the current supply of PET facilities might exceed actual demand for the service. The efficiency of resource allocation should be taken into consideration in the future health service researches on PET. (author)

  1. Atlas of PET/MR imaging in oncology

    International Nuclear Information System (INIS)

    Ratib, Osman; Schwaiger, Markus; Beyer, Thomas

    2013-01-01

    Numerous illustrated clinical cases in different oncology domains. Includes digital interactive software matching the cases in the book. Interactive version based on the latest web standard, HTML5, ensuring the widest compatibility. Edited by three international opinion leaders/imaging experts in the field. This new project on PET/MR imaging in oncology includes digital interactive software matching the cases in the book. The interactive version of the atlas is based on the latest web standard, HTML5, ensuring compatibility with any computer operating system as well as a dedicated version for Apple iPad and iPhone. The book opens with an introduction to the principles of hybrid imaging that pays particular attention to PET/MR imaging and standard PET/MR acquisition protocols. A wide range of illustrated clinical case reports are then presented. Each case study includes a short clinical history, findings, and teaching points, followed by illustrations, legends, and comments. The multimedia version of the book includes dynamic movies that allow the reader to browse through series of rotating 3D images (MIP or volume rendered), display blending between PET and MR, and dynamic visualization of 3D image volumes. The movies can be played either continuously or sequentially for better exploration of sets of images. The editors of this state-of-the-art publication are key opinion leaders in the field of multimodality imaging. Professor Osman Ratib (Geneva) and Professor Markus Schwaiger (Munich) were the first in Europe to initiate the clinical adoption of PET/MR imaging. Professor Thomas Beyer (Zurich) is an internationally renowned pioneering physicist in the field of hybrid imaging. Individual clinical cases presented in this book are co-authored by leading international radiologists and nuclear physicians experts in the use of PET and MRI.

  2. Atlas of PET/MR imaging in oncology

    Energy Technology Data Exchange (ETDEWEB)

    Ratib, Osman [University Hospital of Geneva (Switzerland). Nuclear Medicine Division; Schwaiger, Markus [Technische Univ. Muenchen (Germany). Nuklearmedizinische Klinik und Poliklinik; Beyer, Thomas (eds.) [General Hospital Vienna (Austria). Center for Medical Physics and Biomedical Engineering

    2013-08-01

    Numerous illustrated clinical cases in different oncology domains. Includes digital interactive software matching the cases in the book. Interactive version based on the latest web standard, HTML5, ensuring the widest compatibility. Edited by three international opinion leaders/imaging experts in the field. This new project on PET/MR imaging in oncology includes digital interactive software matching the cases in the book. The interactive version of the atlas is based on the latest web standard, HTML5, ensuring compatibility with any computer operating system as well as a dedicated version for Apple iPad and iPhone. The book opens with an introduction to the principles of hybrid imaging that pays particular attention to PET/MR imaging and standard PET/MR acquisition protocols. A wide range of illustrated clinical case reports are then presented. Each case study includes a short clinical history, findings, and teaching points, followed by illustrations, legends, and comments. The multimedia version of the book includes dynamic movies that allow the reader to browse through series of rotating 3D images (MIP or volume rendered), display blending between PET and MR, and dynamic visualization of 3D image volumes. The movies can be played either continuously or sequentially for better exploration of sets of images. The editors of this state-of-the-art publication are key opinion leaders in the field of multimodality imaging. Professor Osman Ratib (Geneva) and Professor Markus Schwaiger (Munich) were the first in Europe to initiate the clinical adoption of PET/MR imaging. Professor Thomas Beyer (Zurich) is an internationally renowned pioneering physicist in the field of hybrid imaging. Individual clinical cases presented in this book are co-authored by leading international radiologists and nuclear physicians experts in the use of PET and MRI.

  3. Small Orbital Stereo Tracking Camera Technology Development

    Science.gov (United States)

    Gagliano, L.; Bryan, T.; MacLeod, T.

    On-Orbit Small Debris Tracking and Characterization is a technical gap in the current National Space Situational Awareness necessary to safeguard orbital assets and crew. This poses a major risk of MOD damage to ISS and Exploration vehicles. In 2015 this technology was added to NASAs Office of Chief Technologist roadmap. For missions flying in or assembled in or staging from LEO, the physical threat to vehicle and crew is needed in order to properly design the proper level of MOD impact shielding and proper mission design restrictions. Need to verify debris flux and size population versus ground RADAR tracking. Use of ISS for In-Situ Orbital Debris Tracking development provides attitude, power, data and orbital access without a dedicated spacecraft or restricted operations on-board a host vehicle as a secondary payload. Sensor Applicable to in-situ measuring orbital debris in flux and population in other orbits or on other vehicles. Could enhance safety on and around ISS. Some technologies extensible to monitoring of extraterrestrial debris as well To help accomplish this, new technologies must be developed quickly. The Small Orbital Stereo Tracking Camera is one such up and coming technology. It consists of flying a pair of intensified megapixel telephoto cameras to evaluate Orbital Debris (OD) monitoring in proximity of International Space Station. It will demonstrate on-orbit optical tracking (in situ) of various sized objects versus ground RADAR tracking and small OD models. The cameras are based on Flight Proven Advanced Video Guidance Sensor pixel to spot algorithms (Orbital Express) and military targeting cameras. And by using twin cameras we can provide Stereo images for ranging & mission redundancy. When pointed into the orbital velocity vector (RAM), objects approaching or near the stereo camera set can be differentiated from the stars moving upward in background.

  4. Multi-modality image reconstruction for dual-head small-animal PET

    International Nuclear Information System (INIS)

    Huang, Chang-Han; Chou, Cheng-Ying

    2015-01-01

    The hybrid positron emission tomography/computed tomography (PET/CT) or positron emission tomography/magnetic resonance imaging (PET/MRI) has become routine practice in clinics. The applications of multi-modality imaging can also benefit research advances. Consequently, dedicated small-imaging system like dual-head small-animal PET (DHAPET) that possesses the advantages of high detection sensitivity and high resolution can exploit the structural information from CT or MRI. It should be noted that the special detector arrangement in DHAPET leads to severe data truncation, thereby degrading the image quality. We proposed to take advantage of anatomical priors and total variation (TV) minimization methods to reconstruct PET activity distribution form incomplete measurement data. The objective is to solve the penalized least-squares function consisted of data fidelity term, TV norm and medium root priors. In this work, we employed the splitting-based fast iterative shrinkage/thresholding algorithm to split smooth and non-smooth functions in the convex optimization problems. Our simulations studies validated that the images reconstructed by use of the proposed method can outperform those obtained by use of conventional expectation maximization algorithms or that without considering the anatomical prior information. Additionally, the convergence rate is also accelerated.

  5. Regional cerebral blood flow measurement using a scintillation camera

    International Nuclear Information System (INIS)

    Heiss, W.D.

    1979-01-01

    A scintillation camera connected to auxillary equipment with off-line data processing or connected to an on-line dedicated computer system permits measurement of hemispheric and regional cerebral blood flow. Reliable flow values are obtained from regions limited in size by spatial resolution and the count rates achieved. Flow measurements obtained with the camera are able to resolve inhomogeneities of cerebral circulation in normal subjects. In a variety of clinical conditions, the localization, severity and extent of flow alterations are shown. Results of flow measurements in individual cases elucidate the pathogenesis of neurologic deficits, quantify the damage to the brain, indicate therapeutic measures of potential value and permit an estimation of the further clinical course. With restricted spatial resolution, flow measurements after intravenous 133 Xe injection are also feasible

  6. Initial experience with a prototype dual-crystal (LSO/NaI) dual-head coincidence camera in oncology

    International Nuclear Information System (INIS)

    Joshi, Urvi; Boellaard, Ronald; Comans, Emile F.I.; Raijmakers, Pieter G.H.M.; Pijpers, Rik J.; Teule, Gerrit J.J.; Lingen, Arthur van; Hoekstra, Otto S.; Miller, Steven D.

    2004-01-01

    The aim of this study was to evaluate the in vivo performance of a prototype dual-crystal [lutetium oxyorthosilicate (LSO)/sodium iodide (NaI)] dual-head coincidence camera (DHC) for PET and SPET (LSO-PS), in comparison to BGO-PET with fluorine-18 fluorodeoxyglucose (FDG) in oncology. This follows earlier reports that LSO-PS has noise-equivalent counting (NEC) rates comparable to partial ring BGO-PET, i.e. clearly higher than standard NaI DHCs. Twenty-four randomly selected oncological patients referred for whole-body FDG-PET underwent BGO-PET followed by LSO-PS. Four nuclear medicine physicians were randomised to read a single scan modality, in terms of lesion intensity, location and likelihood of malignancy. BGO-PET was considered the gold standard. Forty-eight lesions were classified as positive with BGO-PET, of which LSO-PS identified 73% (95% CI 60-86%). There was good observer agreement for both modalities in terms of intensity, location and interpretation. Lesions were missed by LSO-PS in 13 patients in the chest (n=6), neck (n=3) and abdomen (n=4). The diameter of these lesions was estimated to be 0.5-1 cm. Initial results justify further evaluation of LSO-PS in specific clinical situations, especially if a role as an instrument of triage for PET is foreseen. (orig.)

  7. High-Resolution PET Detector. Final report

    International Nuclear Information System (INIS)

    Karp, Joel

    2014-01-01

    The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface

  8. Decreased occipital lobe metabolism by FDG-PET/CT: An anti-NMDA receptor encephalitis biomarker.

    Science.gov (United States)

    Probasco, John C; Solnes, Lilja; Nalluri, Abhinav; Cohen, Jesse; Jones, Krystyna M; Zan, Elcin; Javadi, Mehrbod S; Venkatesan, Arun

    2018-01-01

    To compare brain metabolism patterns on fluorodeoxyglucose (FDG)-PET/CT in anti-NMDA receptor and other definite autoimmune encephalitis (AE) and to assess how these patterns differ between anti-NMDA receptor neurologic disability groups. Retrospective review of clinical data and initial dedicated brain FDG-PET/CT studies for neurology inpatients with definite AE, per published consensus criteria, treated at a single academic medical center over a 10-year period. Z-score maps of FDG-PET/CT were made using 3-dimensional stereotactic surface projections in comparison to age group-matched controls. Brain region mean Z scores with magnitudes ≥2.00 were interpreted as significant. Comparisons were made between anti-NMDA receptor and other definite AE patients as well as among patients with anti-NMDA receptor based on modified Rankin Scale (mRS) scores at the time of FDG-PET/CT. The medial occipital lobes were markedly hypometabolic in 6 of 8 patients with anti-NMDA receptor encephalitis and as a group (Z = -4.02, interquartile range [IQR] 2.14) relative to those with definite AE (Z = -2.32, 1.46; p = 0.004). Among patients with anti-NMDA receptor encephalitis, the lateral and medial occipital lobes were markedly hypometabolic for patients with mRS 4-5 (lateral occipital lobe Z = -3.69, IQR 1; medial occipital lobe Z = -4.08, 1) compared with those with mRS 0-3 (lateral occipital lobe Z = -0.83, 2; p occipital lobe Z = -1.07, 2; p = 0.001). Marked medial occipital lobe hypometabolism by dedicated brain FDG-PET/CT may serve as an early biomarker for discriminating anti-NMDA receptor encephalitis from other AE. Resolution of lateral and medial occipital hypometabolism may correlate with improved neurologic status in anti-NMDA receptor encephalitis.

  9. Multiparametric evaluation by simultaneous PET-MRI examination in patients with histologically proven laryngeal cancer

    International Nuclear Information System (INIS)

    Cavaliere, Carlo; Romeo, Valeria; Aiello, Marco; Mesolella, Massimo; Iorio, Brigida; Barbuto, Luigi; Cantone, Elena; Nicolai, Emanuele; Covello, Mario

    2017-01-01

    Highlights: • PET/MRI is feasible and useful for primary staging of laryngeal cancer. • PET/MRI simultaneously provides morphological, metabolic and functional parameters of tumoral laryngeal lesions. • PET/MRI allows an appropriate tumoral staging in terms of lesion extension with significant impact on therapeutic strategies. - Abstract: Objectives: To evaluate the relationship between metabolic 18Fluoro-Deoxyglucose-Positron Emission Tomography (18FDG/PET) and morpho-functional parameters derived by Magnetic Resonance Imaging (MRI) in patients with histologically proven laryngeal cancer. To assess the clinical impact of PET/MRI examination on patient’s staging and treatment planning. Methods: 16 patients with histologically proven laryngeal cancer were enrolled and underwent whole body PET/CT followed by a dedicated PET/MRI of the head/neck region. Data were separately evaluated by two blinded groups: metabolic (SUV and MTV), diffusion (ADC) and perfusion (K trans , V e , k ep and iAUC) maps were obtained by positioning regions of interest (ROIs). Tumoral local extension assessed on PET/MRI was compared to endoscopic findings. Results: A good inter-observer agreement was found in anatomical location and local extension of PET/MRI lesions (Cohen’s kappa 0.9). PET/CT SUV measures highly correlate with ones derived by PET/MRI (e.g., p = 0.96 for measures on VOI). Significant correlations among metabolic, diffusion and perfusion parameters have been detected. PET/MRI had a relevant clinical impact, confirming endoscopic findings (6 cases), helping treatment planning (9 cases), and modifying endoscopic primary staging (1 case). Conclusions: PET/MRI is useful for primary staging of laryngeal cancer, allowing simultaneous collection of metabolic and functional data and conditioning the therapeutic strategies.

  10. Multiparametric evaluation by simultaneous PET-MRI examination in patients with histologically proven laryngeal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Cavaliere, Carlo [IRCCS SDN, Via E. Gianturco, 113-80143, Naples (Italy); Romeo, Valeria, E-mail: valeria.romeo@unina.it [Department of Advanced Biomedical Sciences, Federico II University, Naples (Italy); Aiello, Marco [IRCCS SDN, Via E. Gianturco, 113-80143, Naples (Italy); Mesolella, Massimo; Iorio, Brigida [Department of Neuroscience, Reproductive and Odontostomatologic Science, ENT Section, Federico II University, Naples (Italy); Barbuto, Luigi [Department of Advanced Biomedical Sciences, Federico II University, Naples (Italy); Cantone, Elena [Department of Neuroscience, Reproductive and Odontostomatologic Science, ENT Section, Federico II University, Naples (Italy); Nicolai, Emanuele; Covello, Mario [IRCCS SDN, Via E. Gianturco, 113-80143, Naples (Italy)

    2017-03-15

    Highlights: • PET/MRI is feasible and useful for primary staging of laryngeal cancer. • PET/MRI simultaneously provides morphological, metabolic and functional parameters of tumoral laryngeal lesions. • PET/MRI allows an appropriate tumoral staging in terms of lesion extension with significant impact on therapeutic strategies. - Abstract: Objectives: To evaluate the relationship between metabolic 18Fluoro-Deoxyglucose-Positron Emission Tomography (18FDG/PET) and morpho-functional parameters derived by Magnetic Resonance Imaging (MRI) in patients with histologically proven laryngeal cancer. To assess the clinical impact of PET/MRI examination on patient’s staging and treatment planning. Methods: 16 patients with histologically proven laryngeal cancer were enrolled and underwent whole body PET/CT followed by a dedicated PET/MRI of the head/neck region. Data were separately evaluated by two blinded groups: metabolic (SUV and MTV), diffusion (ADC) and perfusion (K{sub trans}, V{sub e}, k{sub ep} and iAUC) maps were obtained by positioning regions of interest (ROIs). Tumoral local extension assessed on PET/MRI was compared to endoscopic findings. Results: A good inter-observer agreement was found in anatomical location and local extension of PET/MRI lesions (Cohen’s kappa 0.9). PET/CT SUV measures highly correlate with ones derived by PET/MRI (e.g., p = 0.96 for measures on VOI). Significant correlations among metabolic, diffusion and perfusion parameters have been detected. PET/MRI had a relevant clinical impact, confirming endoscopic findings (6 cases), helping treatment planning (9 cases), and modifying endoscopic primary staging (1 case). Conclusions: PET/MRI is useful for primary staging of laryngeal cancer, allowing simultaneous collection of metabolic and functional data and conditioning the therapeutic strategies.

  11. ITEM-QM solutions for EM problems in image reconstruction exemplary for the Compton Camera

    CERN Document Server

    Pauli, Josef; Anton, G

    2002-01-01

    Imaginary time expectation maximation (ITEM), a new algorithm for expectation maximization problems based on the quantum mechanics energy minimalization via imaginary (euclidian) time evolution is presented. Both (the algorithm as well as the implementation (http://www.johannes-pauli.de/item/index.html) are published under the terms of General GNU public License (http://www.gnu.org/copyleft/gpl.html). Due to its generality ITEM is applicable to various image reconstruction problems like CT, PET, SPECT, NMR, Compton Camera, tomosynthesis as well as any other energy minimization problem. The choice of the optimal ITEM Hamiltonian is discussed and numerical results are presented for the Compton Camera.

  12. Upgrading of analogue cameras using modern PC based computer

    International Nuclear Information System (INIS)

    Pardom, M.F.; Matos, L.

    2002-01-01

    Aim: The use of computers along with analogue cameras enables them to perform tasks involving time-activity parameters. The INFORMENU system converts a modern PC computer into a dedicated nuclear medicine computer system with a total cost affordable to emerging economic countries, and easily adaptable to all existing cameras. Materials and Methods: In collaboration with nuclear medicine physicians, an application including hardware and software was developed by a private firm. The system runs smoothly on Windows 98 and its operation is very easy. The main features are comparable to the brand commercial computer systems; such as image resolution until 1024 x 1024, low count loss at high count rate, uniformity correction, integrated graphical and text reporting, and user defined clinical protocols. Results: The system is used in more than 20 private and public institutions. The count loss is less than 1% in all the routine work, improvement of uniformity correction of 3-5 times, improved utility of the analogue cameras. Conclusion: The INFORMENU system improves the utility of analogue cameras permitting the inclusion of dynamic clinical protocols and quantifications, helping the development of the nuclear medicine practice. The operation and maintenance costs were lowered. The end users improve their knowledge of modern nuclear medicine

  13. A novel fully integrated handheld gamma camera

    International Nuclear Information System (INIS)

    Massari, R.; Ucci, A.; Campisi, C.; Scopinaro, F.; Soluri, A.

    2016-01-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  14. A novel fully integrated handheld gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Massari, R.; Ucci, A.; Campisi, C. [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy); Scopinaro, F. [University of Rome “La Sapienza”, S. Andrea Hospital, Rome (Italy); Soluri, A., E-mail: alessandro.soluri@ibb.cnr.it [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy)

    2016-10-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  15. Positron range in PET imaging: an alternative approach for assessing and correcting the blurring

    DEFF Research Database (Denmark)

    Jødal, Lars; Le Loirec, Cindy; Champion, Christophe

    2012-01-01

    Background: Positron range impairs resolution in PET imaging, especially for high-energy emitters and for small-animal PET. De-blurring in image reconstruction is possible if the blurring distribution is known. Further, the percentage of annihilation events within a given distance from the point...... on allowed-decay isotopes. Methods: It is argued that blurring at the detection level should not be described by positron range r, but instead the 2D-projected distance δ (equal to the closest distance between decay and line-of-response). To determine these 2D distributions, results from a dedicated positron...... is important for improved resolution in PET imaging. Relevant distributions for positron range have been derived for seven isotopes. Distributions for other allowed-decay isotopes may be estimated with the above formulas....

  16. Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera

    International Nuclear Information System (INIS)

    Ben-Haim, Simona; Kacperski, Krzysztof; Hain, Sharon; Van Gramberg, Dean; Hutton, Brian F.; Erlandsson, Kjell; Waddington, Wendy A.; Ell, Peter J.; Sharir, Tali; Roth, Nathaniel; Berman, Daniel S.

    2010-01-01

    We compared simultaneous dual-radionuclide (DR) stress and rest myocardial perfusion imaging (MPI) with a novel solid-state cardiac camera and a conventional SPECT camera with separate stress and rest acquisitions. Of 27 consecutive patients recruited, 24 (64.5±11.8 years of age, 16 men) were injected with 74 MBq of 201 Tl (rest) and 250 MBq 99m Tc-MIBI (stress). Conventional MPI acquisition times for stress and rest are 21 min and 16 min, respectively. Rest 201 Tl for 6 min and simultaneous DR 15-min list mode gated scans were performed on a D-SPECT cardiac scanner. In 11 patients DR D-SPECT was performed first and in 13 patients conventional stress 99m Tc-MIBI SPECT imaging was performed followed by DR D-SPECT. The DR D-SPECT data were processed using a spill-over and scatter correction method. DR D-SPECT images were compared with rest 201 Tl D-SPECT and with conventional SPECT images by visual analysis employing the 17-segment model and a five-point scale (0 normal, 4 absent) to calculate the summed stress and rest scores. Image quality was assessed on a four-point scale (1 poor, 4 very good) and gut activity was assessed on a four-point scale (0 none, 3 high). Conventional MPI studies were abnormal at stress in 17 patients and at rest in 9 patients. In the 17 abnormal stress studies DR D-SPECT MPI showed 113 abnormal segments and conventional MPI showed 93 abnormal segments. In the nine abnormal rest studies DR D-SPECT showed 45 abnormal segments and conventional MPI showed 48 abnormal segments. The summed stress and rest scores on conventional SPECT and DR D-SPECT were highly correlated (r=0.9790 and 0.9694, respectively). The summed scores of rest 201 Tl D-SPECT and DR-DSPECT were also highly correlated (r=0.9968, p 201 Tl D-SPECT acquisition. (orig.)

  17. Detection of prostate cancer by an FDG-PET cancer screening program: results from a Japanese nationwide survey

    International Nuclear Information System (INIS)

    Minamimoto, Ryogo; Senda, Michio; Jinnouchi, Seishi; Terauchi, Takashi; Inoue, Tomio

    2014-01-01

    The aim of this study was to analyze detection rates and effectiveness of 18 F-fluorodeoxyglucose positron emission tomography (FDG-PET) cancer screening program for prostate cancer in Japan, which is defined as a cancer-screening program for subjects without known cancer. It contains FDG-PET aimed at detection of cancer at an early stage with or without additional screening tests such as prostate-specific antigen (PSA) and magnetic resonance imaging (MRI). A total of 92,255 asymptomatic men underwent the FDG-PET cancer screening program. Of these, 504 cases with findings of possible prostate cancer in any screening method were analyzed. Of the 504 cases, 165 were verified as having prostate cancer. Of these, only 61 cases were detected by FDG-PET, which result in 37.0% relative sensitivity and 32.8% positive predictive value (PPV). The sensitivity of PET/computed tomography (CT) scanner was higher than that of dedicated PET (44.0% vs. 20.4%). However, the sensitivity of FDG-PET was lower than that of PSA and pelvic MRI. FDG-PET did not contribute to improving the sensitivity and PPV when performed as combined screening. PSA should be included in FDG-PET cancer screening programs to screen for prostate cancer

  18. Value of PET/CT 3D visualization of head and neck squamous cell carcinoma extended to mandible.

    Science.gov (United States)

    Lopez, R; Gantet, P; Julian, A; Hitzel, A; Herbault-Barres, B; Alshehri, S; Payoux, P

    2018-05-01

    To study an original 3D visualization of head and neck squamous cell carcinoma extending to the mandible by using [18F]-NaF PET/CT and [18F]-FDG PET/CT imaging along with a new innovative FDG and NaF image analysis using dedicated software. The main interest of the 3D evaluation is to have a better visualization of bone extension in such cancers and that could also avoid unsatisfying surgical treatment later on. A prospective study was carried out from November 2016 to September 2017. Twenty patients with head and neck squamous cell carcinoma extending to the mandible (stage 4 in the UICC classification) underwent [18F]-NaF and [18F]-FDG PET/CT. We compared the delineation of 3D quantification obtained with [18F]-NaF and [18F]-FDG PET/CT. In order to carry out this comparison, a method of visualisation and quantification of PET images was developed. This new approach was based on a process of quantification of radioactive activity within the mandibular bone that objectively defined the significant limits of this activity on PET images and on a 3D visualization. Furthermore, the spatial limits obtained by analysis of the PET/CT 3D images were compared to those obtained by histopathological examination of mandibular resection which confirmed intraosseous extension to the mandible. The [18F]-NaF PET/CT imaging confirmed the mandibular extension in 85% of cases and was not shown in [18F]-FDG PET/CT imaging. The [18F]-NaF PET/CT was significantly more accurate than [18F]-FDG PET/CT in 3D assessment of intraosseous extension of head and neck squamous cell carcinoma. This new 3D information shows the importance in the imaging approach of cancers. All cases of mandibular extension suspected on [18F]-NaF PET/CT imaging were confirmed based on histopathological results as a reference. The [18F]-NaF PET/CT 3D visualization should be included in the pre-treatment workups of head and neck cancers. With the use of a dedicated software which enables objective delineation of

  19. Thoracic cavity definition for 3D PET/CT analysis and visualization.

    Science.gov (United States)

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W; Higgins, William E

    2015-07-01

    X-ray computed tomography (CT) and positron emission tomography (PET) serve as the standard imaging modalities for lung-cancer management. CT gives anatomical details on diagnostic regions of interest (ROIs), while PET gives highly specific functional information. During the lung-cancer management process, a patient receives a co-registered whole-body PET/CT scan pair and a dedicated high-resolution chest CT scan. With these data, multimodal PET/CT ROI information can be gleaned to facilitate disease management. Effective image segmentation of the thoracic cavity, however, is needed to focus attention on the central chest. We present an automatic method for thoracic cavity segmentation from 3D CT scans. We then demonstrate how the method facilitates 3D ROI localization and visualization in patient multimodal imaging studies. Our segmentation method draws upon digital topological and morphological operations, active-contour analysis, and key organ landmarks. Using a large patient database, the method showed high agreement to ground-truth regions, with a mean coverage=99.2% and leakage=0.52%. Furthermore, it enabled extremely fast computation. For PET/CT lesion analysis, the segmentation method reduced ROI search space by 97.7% for a whole-body scan, or nearly 3 times greater than that achieved by a lung mask. Despite this reduction, we achieved 100% true-positive ROI detection, while also reducing the false-positive (FP) detection rate by >5 times over that achieved with a lung mask. Finally, the method greatly improved PET/CT visualization by eliminating false PET-avid obscurations arising from the heart, bones, and liver. In particular, PET MIP views and fused PET/CT renderings depicted unprecedented clarity of the lesions and neighboring anatomical structures truly relevant to lung-cancer assessment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Dynamic Human Body Modeling Using a Single RGB Camera.

    Science.gov (United States)

    Zhu, Haiyu; Yu, Yao; Zhou, Yu; Du, Sidan

    2016-03-18

    In this paper, we present a novel automatic pipeline to build personalized parametric models of dynamic people using a single RGB camera. Compared to previous approaches that use monocular RGB images, our system can model a 3D human body automatically and incrementally, taking advantage of human motion. Based on coarse 2D and 3D poses estimated from image sequences, we first perform a kinematic classification of human body parts to refine the poses and obtain reconstructed body parts. Next, a personalized parametric human model is generated by driving a general template to fit the body parts and calculating the non-rigid deformation. Experimental results show that our shape estimation method achieves comparable accuracy with reconstructed models using depth cameras, yet requires neither user interaction nor any dedicated devices, leading to the feasibility of using this method on widely available smart phones.

  1. First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study.

    Science.gov (United States)

    Agostini, Denis; Roule, Vincent; Nganoa, Catherine; Roth, Nathaniel; Baavour, Raphael; Parienti, Jean-Jacques; Beygui, Farzin; Manrique, Alain

    2018-07-01

    We assessed the feasibility of myocardial blood flow (MBF) and flow reserve (MFR) estimation using dynamic SPECT with a novel CZT camera in patients with stable CAD, in comparison with 15 O-water PET and fractional flow reserve (FFR). Thirty patients were prospectively included and underwent FFR measurements in the main coronary arteries (LAD, LCx, RCA). A stenosis ≥50% was considered obstructive and a FFR abnormal if ≤0.8. All patients underwent a dynamic rest/stress 99m Tc-sestamibi CZT-SPECT and 15 O-water PET for MBF and MFR calculation. Net retention kinetic modeling was applied to SPECT data to estimate global uptake values, and MBF was derived using Leppo correction. Ischemia by PET and CZT-SPECT was considered present if MFR was lower than 2 and 2.1, respectively. CZT-SPECT yielded higher stress and rest MBF compared to PET for global and LAD and LCx territories, but not in RCA territory. MFR was similar in global and each vessel territory for both modalities. The sensitivity, specificity, accuracy, positive and negative predictive value of CZT-SPECT were, respectively, 83.3, 95.8, 93.3, 100 and 85.7% for the detection of ischemia and 58.3, 84.6, 81.1, 36.8 and 93% for the detection of hemodynamically significant stenosis (FFR ≤ 0.8). Dynamic 99m Tc-sestamibi CZT-SPECT was technically feasible and provided similar MFR compared to 15 O-water PET and high diagnostic value for detecting impaired MFR and abnormal FFR in patients with stable CAD.

  2. FDG PET in the diagnosis of giant cell arteritis

    International Nuclear Information System (INIS)

    Turlakow, A.; Yeung, H.W.D.; Pui, J.; Macapinlac, H.; Liebovitz, E.; Rusch, V.; Goy, A.; Larson, S.M.

    2003-01-01

    Full text: To evaluate the role of PET in the diagnosis of vasculitis. Methods: We report a case of giant cell arteritis diagnosed by FDG-PET in a 75-year-old woman with a fever of unknown origin. The patient presented with a 3 month history of fatigue, fevers, headaches, visual disturbance and jaw claudication. Diagnosis of temporal arteritis was initially excluded because of a normal ESR. CT scan showed an anterior mediastinal mass, suspicious for malignancy. An FDG-PET scan for pre-operative evaluation was acquired 45 minutes after intravenous injection of 10 mCi F18-FDG, on a dedicated PET scanner. Image reconstruction was performed using an iterative algorithm with segmented attenuation correction. The study identified striking localisation of FDG to the entire aorta, left main coronary artery, and subclavian, carotid and common iliac arteries bilaterally (SUV max range 4-4.5 g/ml), suggestive of large vessel arteritis. Subsequent excisional biopsy of the mediastinal mass confirmed giant cell vasculitis of a large muscular artery in thymic tissue. No malignancy was detected. A repeat ESR was 129 mm/hr. The patient was commenced on oral Prednisone, with prompt improvement of symptoms, ESR and anaemia and complete normalisation of the FDG-PET scan within two weeks. This case suggests a potential role of FDG-PET in the non-invasive diagnosis, classification and follow-up of giant cell arteritis, and possibly other vasculitides, so far notoriously difficult to diagnose, relying usually on a constellation of non-specific symptoms, laboratory investigations or invasive pathologic and angiographic means. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  3. Monte Carlo simulation for dual head gamma camera

    International Nuclear Information System (INIS)

    Osman, Yousif Bashir Soliman

    2015-12-01

    Monte Carlo (MC) simulation technique was used widely in medical physics applications. In nuclear medicine MC was used to design new medical imaging devices such as positron emission tomography (PET), gamma camera and single photon emission computed tomography (SPECT). Also it can be used to study the factors affecting image quality and internal dosimetry, Gate is on of monte Carlo code that has a number of advantages for simulation of SPECT and PET. There is a limit accessibilities in machines which are used in clinics because of the work load of machines. This makes it hard to evaluate some factors effecting machine performance which must be evaluated routinely. Also because of difficulties of carrying out scientific research and training of students, MC model can be optimum solution for the problem. The aim of this study was to use gate monte Carlo code to model Nucline spirit, medico dual head gamma camera hosted in radiation and isotopes center of Khartoum which is equipped with low energy general purpose LEGP collimators. This was used model to evaluate spatial resolution and sensitivity which is important factor affecting image quality and to demonstrate the validity of gate by comparing experimental results with simulation results on spatial resolution. The gate model of Nuclide spirit, medico dual head gamma camera was developed by applying manufacturer specifications. Then simulation was run. In evaluation of spatial resolution the FWHM was calculated from image profile of line source of Tc 99m gammas emitter of energy 140 KeV at different distances from modeled camera head at 5,10,15,20,22,27,32,37 cm and for these distances the spatial resolution was founded to be 5.76, 7.73, 10.7, 13.8, 14.01,16.91, 19.75 and 21.9 mm, respectively. These results showed a decrement of spatial resolution with increase of the distance between object (line source) and collimator in linear manner. FWHM calculated at 10 cm was compared with experimental results. The

  4. Imaging and PET - PET/CT imaging

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Hany, Th.F.

    2008-01-01

    PET/CT has grown because the lack of anatomic landmarks in PET makes 'hardware-fusion' to anatomic cross-sectional data extremely useful. Addition of CT to PET improves specificity, but also sensitivity, and adding PET to CT adds sensitivity and specificity in tumor imaging. The synergistic advantage of adding CT is that the attenuation correction needed for PET data can also be derived from the CT data. This makes PET-CT 25-30% faster than PET alone, leading to higher patient throughput and a more comfortable examination for patients typically lasting 20 minutes or less. FDG-PET-CT appears to provide relevant information in the staging and therapy monitoring of many tumors, such as lung carcinoma, colorectal cancer, lymphoma, gynaecological cancers, melanoma and many others, with the notable exception of prostatic cancer. for this cancer, choline derivatives may possibly become useful radiopharmaceuticals. The published literature on the applications of FDG-PET-CT in oncology is still limited but several designed studies have demonstrated the benefits of PET-CT. (authors)

  5. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.

    Science.gov (United States)

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-02-01

    The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  6. The role of the US Army Veterinary Corps in military family pet health.

    Science.gov (United States)

    Vincent-Johnson, Nancy A

    2013-01-01

    Even though privately-owned pet care is a lower priority mission than military working dog care, food inspection,and the public health mission, it is still very important,and the one that many Veterinary Corps officers, civil-ian veterinarians, and technicians enjoy the most. The vast majority of veterinarians and technicians went into veterinary medicine because of a love for animals. It is fulfilling to offer guidance to a client with a new puppy or kitten, see a sick pet improve after treatment, and interact with dozens of animals and clients in a day. The services provided by the Army Veterinary Corps in car-ing for pets has expanded over the years and the standard of care has improved as well. It is truly a privilege to serve those who dedicate themselves to the protection of our Nation. The Army Veterinary Corps is indeed proud to provide care to the pets of Warfighters of the Army,Navy, Marine Corps, Air Force, and Coast Guard; their family members; and our military retirees.

  7. A contactless approach for respiratory gating in PET using continuous-wave radar

    Energy Technology Data Exchange (ETDEWEB)

    Ersepke, Thomas, E-mail: Thomas.Ersepke@rub.de; Büther, Florian; Heß, Mirco [European Institute for Molecular Imaging, University of Münster, Münster 48149 (Germany); Schäfers, Klaus P. [European Institute for Molecular Imaging, University of Münster, Münster 48149, Germany and DFG EXC 1003, Cluster of Excellence ‘Cells in Motion,’ Münster 48149 (Germany)

    2015-08-15

    Purpose: Respiratory gating is commonly used to reduce motion artifacts in positron emission tomography (PET). Clinically established methods for respiratory gating in PET require contact to the patient or a direct optical line between the sensor and the patient’s torso and time consuming preparation. In this work, a contactless method for capturing a respiratory signal during PET is presented based on continuous-wave radar. Methods: The proposed method relies on the principle of emitting an electromagnetic wave and detecting the phase shift of the reflected wave, modulated due to the respiratory movement of the patient’s torso. A 24 GHz carrier frequency was chosen allowing wave propagation through plastic and clothing with high reflections at the skin surface. A detector module and signal processing algorithms were developed to extract a quantitative respiratory signal. The sensor was validated using a high precision linear table. During volunteer measurements and [{sup 18}F] FDG PET scans, the radar sensor was positioned inside the scanner bore of a PET/computed tomography scanner. As reference, pressure belt (one volunteer), depth camera-based (two volunteers, two patients), and PET data-driven (six patients) signals were acquired simultaneously and the signal correlation was quantified. Results: The developed system demonstrated a high measurement accuracy for movement detection within the submillimeter range. With the proposed method, small displacements of 25 μm could be detected, not considerably influenced by clothing or blankets. From the patient studies, the extracted respiratory radar signals revealed high correlation (Pearson correlation coefficient) to those derived from the external pressure belt and depth camera signals (r = 0.69–0.99) and moderate correlation to those of the internal data-driven signals (r = 0.53–0.70). In some cases, a cardiac signal could be visualized, due to the representation of the mechanical heart motion on the skin

  8. FDG-PET/CT brain findings in a patient with macrophagic myofascilitis

    Energy Technology Data Exchange (ETDEWEB)

    Der Gucht, Axel Van; Itti, Emmanuel; Aoun-Sebaliti, Mehdi; Kauv, Paul; Aouizerate, Jessie; Gherardi, Romain K.; Bachoud-Levi, Anne-Catherine; Authier, Francois-Jerome [Paris/Paris-Est University, Paris (France); Verger, Antoine [CHU Nancy, Nuclear Medecine and Nancyclotep Experimental Imaging Platform, Nancy (France); Guedj, Eric [Assistance Publique des Hircumflex, Marseille (France)

    2016-03-15

    Brain Positron Emission Tomography/Computed Tomography with {sup 18}F-fluorodeoxyglucose (FDG PET/CT) was performed in a 44-year-old woman with marked cognitive impairment, diffuse myalgias, sensory, memory and visual disorders, and chronic fatigue, presenting with histopathological features of macrophagic myofasciitis (MMF) at deltoid muscle biopsy. Cerebromedullary Magnetic Resonance Imaging (MRI), electromyography, ophthalmic examination, and cerebrospinal fluid analysis were normal. Visual analysis of FDG PET/CT images showed an atypical pattern of hypometabolism, involving symmetrically the occipital cortex, temporal lobes, and limbic system (including in particular amygdalo-hippocampal complexes), and the cerebellum. Posterior cingulate cortex and parietal areas were preserved. This pattern was confirmed by a voxel-based procedure using Statistical Parametric Mapping (SPM12) that compared a patient's images to normal reference samples from six healthy subjects with adjustment to age obtained using the same PET/CT camera. These results provide a glucose metabolism substrate for cognitive complaints in patients with long-lasting aluminium hydroxide-induced MMF.

  9. FDG-PET/CT brain findings in a patient with macrophagic myofascilitis

    International Nuclear Information System (INIS)

    Der Gucht, Axel Van; Itti, Emmanuel; Aoun-Sebaliti, Mehdi; Kauv, Paul; Aouizerate, Jessie; Gherardi, Romain K.; Bachoud-Levi, Anne-Catherine; Authier, Francois-Jerome; Verger, Antoine; Guedj, Eric

    2016-01-01

    Brain Positron Emission Tomography/Computed Tomography with 18 F-fluorodeoxyglucose (FDG PET/CT) was performed in a 44-year-old woman with marked cognitive impairment, diffuse myalgias, sensory, memory and visual disorders, and chronic fatigue, presenting with histopathological features of macrophagic myofasciitis (MMF) at deltoid muscle biopsy. Cerebromedullary Magnetic Resonance Imaging (MRI), electromyography, ophthalmic examination, and cerebrospinal fluid analysis were normal. Visual analysis of FDG PET/CT images showed an atypical pattern of hypometabolism, involving symmetrically the occipital cortex, temporal lobes, and limbic system (including in particular amygdalo-hippocampal complexes), and the cerebellum. Posterior cingulate cortex and parietal areas were preserved. This pattern was confirmed by a voxel-based procedure using Statistical Parametric Mapping (SPM12) that compared a patient's images to normal reference samples from six healthy subjects with adjustment to age obtained using the same PET/CT camera. These results provide a glucose metabolism substrate for cognitive complaints in patients with long-lasting aluminium hydroxide-induced MMF

  10. Simulating effects of brain atrophy in longitudinal PET imaging with an anthropomorphic brain phantom

    DEFF Research Database (Denmark)

    Jonasson, L S; Axelsson, J; Riklund, K

    2017-01-01

    In longitudinal positron emission tomography (PET), the presence of volumetric changes over time can lead to an overestimation or underestimation of the true changes in the quantified PET signal due to the partial volume effect (PVE) introduced by the limited spatial resolution of existing PET...... cameras and reconstruction algorithms. Here, a 3D-printed anthropomorphic brain phantom with attachable striata in three sizes was designed to enable controlled volumetric changes. Using a method to eliminate the non-radioactive plastic wall, and manipulating BP levels by adding different number of events...... from list-mode acquisitions, we investigated the artificial volume dependence of BP due to PVE, and potential bias arising from varying BP. Comparing multiple reconstruction algorithms we found that a high-resolution ordered-subsets maximization algorithm with spatially variant point-spread function...

  11. The PETRRA positron camera: design, characterization and results of a physical evaluation

    International Nuclear Information System (INIS)

    Divoli, A; Flower, M A; Erlandsson, K; Reader, A J; Evans, N; Meriaux, S; Ott, R J; Stephenson, R; Bateman, J E; Duxbury, D M; Spill, E J

    2005-01-01

    The PETRRA positron camera is a large-area (600 mm x 400 mm sensitive area) prototype system that has been developed through a collaboration between the Rutherford Appleton Laboratory and the Institute of Cancer Research/Royal Marsden Hospital. The camera uses novel technology involving the coupling of 10 mm thick barium fluoride scintillating crystals to multi-wire proportional chambers filled with a photosensitive gas. The performance of the camera is reported here and shows that the present system has a 3D spatial resolution of ∼7.5 mm full-width-half-maximum (FWHM), a timing resolution of ∼3.5 ns (FWHM), a total coincidence count-rate performance of at least 80-90 kcps and a randoms-corrected sensitivity of ∼8-10 kcps kBq -1 ml. For an average concentration of 3 kBq ml -1 as expected in a patient it is shown that, for the present prototype, ∼20% of the data would be true events. The count-rate performance is presently limited by the obsolete off-camera read-out electronics and computer system and the sensitivity by the use of thin (10 mm thick) crystals. The prototype camera has limited scatter rejection and no intrinsic shielding and is, therefore, susceptible to high levels of scatter and out-of-field activity when imaging patients. All these factors are being addressed to improve the performance of the camera. The large axial field-of-view of 400 mm makes the camera ideally suited to whole-body PET imaging. We present examples of preliminary clinical images taken with the prototype camera. Overall, the results show the potential for this alternative technology justifying further development

  12. Improved scintimammography using a high-resolution camera mounted on an upright mammography gantry

    Energy Technology Data Exchange (ETDEWEB)

    Itti, Emmanuel; Patt, Bradley E.; Diggles, Linda E.; MacDonald, Lawrence; Iwanczyk, Jan S.; Mishkin, Fred S.; Khalkhali, Iraj E-mail: nephrad@aol.com

    2003-01-21

    {sup 99m}Tc-sestamibi scintimammography (SMM) is a useful adjunct to conventional X-ray mammography (XMM) for the assessment of breast cancer. An increasing number of studies has emphasized fair sensitivity values for the detection of tumors >1 cm, compared to XMM, particularly in situations where high glandular breast densities make mammographic interpretation difficult. In addition, SMM has demonstrated high specificity for cancer, compared to various functional and anatomic imaging modalities. However, large field-of-view (FOV) gamma cameras are difficult to position close to the breasts, which decreases spatial resolution and subsequently, the sensitivity of detection for tumors <1 cm. New dedicated detectors featuring small FOV and increased spatial resolution have recently been developed. In this setting, improvement in tumor detection sensitivity, particularly with regard to small cancers is expected. At Division of Nuclear Medicine, Harbor-UCLA Medical Center, we have performed over 2000 SMM within the last 9 years. We have recently used a dedicated breast camera (LumaGEM) featuring a 12.8x12.8 cm{sup 2} FOV and an array of 2x2x6 mm{sup 3} discrete crystals coupled to a photon-sensitive photomultiplier tube readout. This camera is mounted on a mammography gantry allowing upright imaging, medial positioning and use of breast compression. Preliminary data indicates significant enhancement of spatial resolution by comparison with standard imaging in the first 10 patients. Larger series will be needed to conclude on sensitivity/specificity issues.

  13. Initial validation of 4D-model for a clinical PET scanner using the Monte Carlo code gate

    International Nuclear Information System (INIS)

    Vieira, Igor F.; Lima, Fernando R.A.; Gomes, Marcelo S.; Vieira, Jose W.; Pacheco, Ludimila M.; Chaves, Rosa M.

    2011-01-01

    Building exposure computational models (ECM) of emission tomography (PET and SPECT) currently has several dedicated computing tools based on Monte Carlo techniques (SimSET, SORTEO, SIMIND, GATE). This paper is divided into two steps: (1) using the dedicated code GATE (Geant4 Application for Tomographic Emission) to build a 4D model (where the fourth dimension is the time) of a clinical PET scanner from General Electric, GE ADVANCE, simulating the geometric and electronic structures suitable for this scanner, as well as some phenomena 4D, for example, rotating gantry; (2) the next step is to evaluate the performance of the model built here in the reproduction of test noise equivalent count rate (NEC) based on the NEMA Standards Publication NU protocols 2-2007 for this tomography. The results for steps (1) and (2) will be compared with experimental and theoretical values of the literature showing actual state of art of validation. (author)

  14. Initial validation of 4D-model for a clinical PET scanner using the Monte Carlo code gate

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Igor F.; Lima, Fernando R.A.; Gomes, Marcelo S., E-mail: falima@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Vieira, Jose W.; Pacheco, Ludimila M. [Instituto Federal de Educacao, Ciencia e Tecnologia (IFPE), Recife, PE (Brazil); Chaves, Rosa M. [Instituto de Radium e Supervoltagem Ivo Roesler, Recife, PE (Brazil)

    2011-07-01

    Building exposure computational models (ECM) of emission tomography (PET and SPECT) currently has several dedicated computing tools based on Monte Carlo techniques (SimSET, SORTEO, SIMIND, GATE). This paper is divided into two steps: (1) using the dedicated code GATE (Geant4 Application for Tomographic Emission) to build a 4D model (where the fourth dimension is the time) of a clinical PET scanner from General Electric, GE ADVANCE, simulating the geometric and electronic structures suitable for this scanner, as well as some phenomena 4D, for example, rotating gantry; (2) the next step is to evaluate the performance of the model built here in the reproduction of test noise equivalent count rate (NEC) based on the NEMA Standards Publication NU protocols 2-2007 for this tomography. The results for steps (1) and (2) will be compared with experimental and theoretical values of the literature showing actual state of art of validation. (author)

  15. Cost-effectiveness of FDG-PET for the management of potentially operable non-small cell lung cancer: priority for a PET-based strategy after nodal-negative CT results

    International Nuclear Information System (INIS)

    Dietlein, M.; Weber, K.; Moka, D.; Theissen, P.; Schicha, H.

    2000-01-01

    Decision analysis is used here to establish the most cost-effective strategy for management of potentially operable non-small cell lung cancers (NSCLCs). The strategies compared were conventional staging (strategy A), dedicated systems of positron emission tomography (PET) using fluorine-18 fluorodeoxyglucose (FDG) in patients with normal-sized (strategy B) or in patients with enlarged mediastinal lymph nodes (part of strategy C), and FDG-PET followed by exclusion from surgical procedures when both computed tomography (CT) and PET were positive for mediastinal lymph nodes (strategy D) or when PET alone was positive (strategy E). Based on published data, the sensitivity and specificity of FDG-PET were estimated at 0.74 and 0.96 for detecting metastasis in normal-sized mediastinal lymph nodes, and at 0.95 and 0.76 when these lymph nodes were enlarged. The calculated probability of up-staging to M1 by using PET was 0.05. The costs quoted correspond to the cost reimbursed in 1999 by the public health provider in Germany. The incremental cost-effectiveness ratio (ICER) of strategy B was much more favourable (143 EUR/LYS; LYS = life year saved) than the ICER of strategy C (36,667 EUR/LYS). In strategy B, the use of PET did not raise the overall costs because the costs of PET were almost balanced by a better selection of patients for beneficial cancer resection. The exclusion from biopsy confirmation in strategies D and E led to cost savings that did not justify the expected reduction in life expectancy. In sensitivity analyses, the ICERs of strategy B were robust to the pretest likelihood of N2/N3, to penalized test parameters of PET and to reimbursement of PET. However, the ICER of strategy B would be raised to 28,000 EUR/LYS through use of thoracic PET without whole-body scanning. To conclude, the implementation of whole-body PET with a full ring of detectors in the preoperative staging of patients with NSCLC and normal-sized lymph nodes is clearly cost

  16. A small animal PET prototype based on Silicon Photomultipliers

    International Nuclear Information System (INIS)

    Marcatili, S; Belcari, N.; Bisogni, M.G.; Del Guerra, A.; Collazuol, G.; Pedreschi, E.; Spinella, F.; Sportelli, G.; Marzocca, C.

    2011-01-01

    Next generation PET scanners should full fill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultiplier (Si P M) matrices is proposed for the construction of a small animal PET system consisting of two detector heads based on Lyso continuos crystals. The use of large area multi-pixel Silicon Photomultiplier (Si P M) detectors requires the development of a multichannel Digital Acquisition system (DAQ) as well as of a dedicated front-end in order not to degrade the intrinsic detector capabilities. At the University of Pisa and INFN Pisa we developed a DAQ board for the read-out of 2 64-pixel Si P M matrices in time coincidence for Positron Emission Tomography (PET) applications. The proof of principles is based on 64-pixel detectors, but the whole system has been conceived to be easily scalable to a higher number of channels. Here we describe the Group-V INFN DASi P M 2 (Development and Application of Si P M) project and related results.

  17. Methodology for creating dedicated machine and algorithm on sunflower counting

    Science.gov (United States)

    Muracciole, Vincent; Plainchault, Patrick; Mannino, Maria-Rosaria; Bertrand, Dominique; Vigouroux, Bertrand

    2007-09-01

    In order to sell grain lots in European countries, seed industries need a government certification. This certification requests purity testing, seed counting in order to quantify specified seed species and other impurities in lots, and germination testing. These analyses are carried out within the framework of international trade according to the methods of the International Seed Testing Association. Presently these different analyses are still achieved manually by skilled operators. Previous works have already shown that seeds can be characterized by around 110 visual features (morphology, colour, texture), and thus have presented several identification algorithms. Until now, most of the works in this domain are computer based. The approach presented in this article is based on the design of dedicated electronic vision machine aimed to identify and sort seeds. This machine is composed of a FPGA (Field Programmable Gate Array), a DSP (Digital Signal Processor) and a PC bearing the GUI (Human Machine Interface) of the system. Its operation relies on the stroboscopic image acquisition of a seed falling in front of a camera. A first machine was designed according to this approach, in order to simulate all the vision chain (image acquisition, feature extraction, identification) under the Matlab environment. In order to perform this task into dedicated hardware, all these algorithms were developed without the use of the Matlab toolbox. The objective of this article is to present a design methodology for a special purpose identification algorithm based on distance between groups into dedicated hardware machine for seed counting.

  18. Initial Experience With Simultaneous 18F-FDG PET/MRI in the Evaluation of Cardiac Sarcoidosis and Myocarditis.

    Science.gov (United States)

    Hanneman, Kate; Kadoch, Michael; Guo, Henry H; Jamali, Mehran; Quon, Andrew; Iagaru, Andrei; Herfkens, Robert

    2017-07-01

    The purpose of this study was to compare combined PET/MRI with PET/CT and cardiac MRI in the evaluation of cardiac sarcoidosis and myocarditis. Ten patients (4 men and 6 women; 56.1 ± 9.6 years old) were prospectively enrolled for evaluation of suspected cardiac sarcoidosis or myocarditis. Written informed consent was obtained. Following administration of 9.9 ± 0.9 mCi F-FDG, patients underwent standard cardiac PET/CT followed by combined PET/MRI using a simultaneous 3-T scanner. Cardiac MRI sequences included ECG-triggered cine SSFP, T2-weighted, and late gadolinium-enhanced imaging. Myocardial involvement was assessed with separate analysis of combined PET/MRI, PET/CT, and cardiac MRI data using dedicated postprocessing software. Estimates of radiation dose were derived from the applied doses of F-FDG and CT protocol parameters. Imaging was acquired with a delay from F-FDG injection of 90.2 ± 27.4 minutes for PET/CT and 207.7 ± 40.3 minutes for PET/MRI. Total scan time for PET/MRI was significantly longer than for PET/CT (81.4 ± 14.8 vs 12.0 minutes, P PET/MRI compared with PET/CT (6.9 ± 0.6 vs 8.2 ± 1.1 mSv, P = 0.007). There was no significant difference in the number of positive cases identified between combined PET/MRI (n = 10 [100%]), PET/CT (n = 6 [60%]), and cardiac MRI (n = 8 [80%]), P = 0.091. Simultaneous cardiac PET/MRI is feasible in the evaluation of cardiac sarcoidosis and myocarditis achieving diagnostic image quality.

  19. Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

    Energy Technology Data Exchange (ETDEWEB)

    Oehmigen, Mark, E-mail: mark.oehmigen@uni-due.de; Lindemann, Maike E. [High Field and Hybrid MR Imaging, University Hospital Essen, Essen 45147 (Germany); Lanz, Titus [Rapid Biomedical GmbH, Rimpar 97222 (Germany); Kinner, Sonja [Institute for Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen 45147 (Germany); Quick, Harald H. [High Field and Hybrid MR Imaging, University Hospital Essen, Essen 45147, Germany and Erwin L. Hahn Institute for MR Imaging, University Duisburg-Essen, Essen 45141 (Germany)

    2016-08-15

    Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating and applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at

  20. FDG-PET imaging for chronic expanding hematoma in pelvis with massive bone destruction

    Energy Technology Data Exchange (ETDEWEB)

    Hamada, Kenichiro [Osaka University Graduate School of Medicine, Department of Nuclear Medicine and Tracer Kinetics, Suita, Osaka (Japan); Osaka University Graduate School of Medicine, Department of Orthopaedic Surgery, Suita, Osaka (Japan); Myoui, Akira; Ueda, Takafumi; Tamai, Noriyuki; Yoshikawa, Hideki [Osaka University Graduate School of Medicine, Department of Orthopaedic Surgery, Suita, Osaka (Japan); Higuchi, Ichiro; Hatazawa, Jun [Osaka University Graduate School of Medicine, Department of Nuclear Medicine and Tracer Kinetics, Suita, Osaka (Japan); Inoue, Atsuo [Osaka University Graduate School of Medicine, Department of Radiology, Suita, Osaka (Japan)

    2005-12-01

    Chronic expanding hematoma is a rare presentation of a hematoma characterized by a persistent increase in size for more than a month after the initial hemorrhage. We present a 65-year-old man with a chronic expanding hematoma in his ilium who was receiving anticoagulant treatment. The patient had a delayed manifestation of a femoral neuropathy with massive bone destruction. 2-Deoxy-[{sup 18}F]fluoro-d-glucose (FDG) positron emission tomography (PET) imaging revealed an increased uptake in the rim of the mass in images acquired 1 h after FDG injection. FDG-PET scans were performed using a dedicated PET scanner (HeadtomeV/SET2400 W, Shimadzu, Kyoto, Japan), and the PET data for the most metabolically active region of interest (ROI) were analyzed. The maximum standardized uptake value (SUVmax) was set to a cut-off point of 3.0 to distinguish between benign and malignant lesions. The SUVmax of the patient's lesion was 3.10, suggesting a malignant lesion. The characteristics of FDG-PET images of chronic expanding hematomas, including the uptake of FDG in the peripheral rim of the mass as a result of inflammation, should be recognized as a potential interpretive pitfall in mimicking a sarcoma. (orig.)

  1. Direct comparison of 18F-FDG and 11C-methionine PET in suspected recurrence of glioma: sensitivity, inter-observer variability and prognostic value

    International Nuclear Information System (INIS)

    Laere, Koen Van; Ceyssens, Sarah; Mortelmans, Luc; Calenbergh, Frank Van; Groot, Tjibbe de; Bormans, Guy; Menten, Johan; Flamen, Patrick

    2005-01-01

    18 F-fluorodeoxyglucose (FDG) and 11 C-methionine (MET) PET imaging studies allow the investigation of metabolism and amino acid transport in brain tumours. Their (relative) usefulness and prognostic value in suspected recurrence or progression of primary brain tumours after previous therapy is an issue of debate. The aim of this study was to compare directly both radioligands in this setting. Cerebral uptake of FDG and MET was determined sequentially on the same day in 30 patients (21 males, nine females; age 40.4±15.6 years), on average 4.0 years (range 0.1-18) after therapy for a primary brain tumour (23 grade II-IV astrocytomas, four oligodendrogliomas and three mixed oligo-astrocytomas). Images were acquired on a Siemens HR+ dedicated PET camera. Two observers scored FDG and MET scans independently. Semi-quantitative indices defined by the tumour (maximum)-to-background ratio were calculated based on manual ROI delineation and by using MET ROIs for FDG after automated co-registration. Patient follow-up was conducted until the last contact with inconspicuous clinical findings (average 41 months, range 12-62 months after PET) [(n=10)] or until death (n=20). Overall median survival was 15.0 months. MET showed pathologically increased uptake in 28/30 scans, and FDG in 17/30. The inter-observer agreement was 100% for MET and 73% for FDG. Using Kaplan-Meier survival analysis, significant differences were found for both FDG (cut-off 0.8, log-rank p=0.007) and MET (cut-off 2.2, log-rank p=0.014). The combination of FDG and MET information resulted in the highest prognostic accuracy (p=0.003), while MET alone was the best prognostic predictor in the subgroup of patients with primary astrocytoma (n=23). FDG and MET PET studies provide complementary prognostic information in patients with suspected brain tumour recurrence or progression after primary therapy. MET is considered the single agent of choice in the evaluation of these patients because of its sensitivity and

  2. Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

    Energy Technology Data Exchange (ETDEWEB)

    Ghafarian, Pardis [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Aghamiri, S.M.R. [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Ay, Mohammad R. [Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Research Institute for Nuclear Medicine, Tehran (Iran, Islamic Republic of); Rahmim, Arman [Johns Hopkins University, Department of Radiology, Baltimore, MD (United States); Schindler, Thomas H. [Geneva University, Cardiovascular Center, Nuclear Cardiology, Geneva (Switzerland); Ratib, Osman [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland)

    2011-02-15

    Cardiac PET/CT imaging is often performed in patients with pacemakers and implantable cardioverter defibrillator (ICD) leads. However, metallic implants usually produce artefacts on CT images which might propagate to CT-based attenuation-corrected (CTAC) PET images. The impact of metal artefact reduction (MAR) for CTAC of cardiac PET/CT images in the presence of pacemaker, ICD and ECG leads was investigated using both qualitative and quantitative analysis in phantom and clinical studies. The study included 14 patients with various leads undergoing perfusion and viability examinations using dedicated cardiac PET/CT protocols. The PET data were corrected for attenuation using both artefactual CT images and CT images corrected using the MAR algorithm. The severity and magnitude of metallic artefacts arising from these leads were assessed on both linear attenuation coefficient maps ({mu}-maps) and attenuation-corrected PET images. CT and PET emission data were obtained using an anthropomorphic thorax phantom and a dedicated heart phantom made in-house incorporating pacemaker and ICD leads attached at the right ventricle of the heart. Volume of interest-based analysis and regression plots were performed for regions related to the lead locations. Bull's eye view analysis was also performed on PET images corrected for attenuation with and without the MAR algorithm. In clinical studies, the visual assessment of PET images by experienced physicians and quantitative analysis did not reveal erroneous interpretation of the tracer distribution or significant differences when PET images were corrected for attenuation with and without MAR. In phantom studies, the mean differences between tracer uptake obtained without and with MAR were 10.16{+-}2.1% and 6.86{+-}2.1% in the segments of the heart in the vicinity of metallic ICD or pacemaker leads, and were 4.43{+-}0.5% and 2.98{+-}0.5% in segments far from the leads. Although the MAR algorithm was able to effectively improve

  3. A High Resolution Clinical PET with Breast and Whole Body Transfigurations

    Science.gov (United States)

    2006-08-01

    random (acci- dental ) coincidence events were measured using a second de- layed coincidence window and then subtracted from the sino- grams measured in the...limits the coincidence timing resolution. For a PET camera with bismuth germinate crystals (BGO), like our HOTPET, the relatively wide timing gate is... germinate crystal) and a new synchronization process must also be set up between the delayed trigger and the energy/position signals before being passed

  4. Positron flight in human tissues and its influence on PET image spatial resolution

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Crespo, Alejandro; Larsson, Stig A. [Section of Nuclear Medicine, Department of Hospital Physics, Karolinska Hospital, 176 76, Stockholm (Sweden); Medical Radiation Physics, Department of Oncology-Pathology, Stockholm University and Karolinska Institute, Stockholm (Sweden); Andreo, Pedro [Medical Radiation Physics, Department of Oncology-Pathology, Stockholm University and Karolinska Institute, Stockholm (Sweden)

    2004-01-01

    The influence of the positron distance of flight in various human tissues on the spatial resolution in positron emission tomography (PET) was assessed for positrons from carbon-11, nitrogen-13, oxygen-15, fluorine-18, gallium-68 and rubidium-82. The investigation was performed using the Monte Carlo code PENELOPE to simulate the transport of positrons within human compact bone, adipose, soft and lung tissue. The simulations yielded 3D distributions of annihilation origins that were projected on the image plane in order to assess their impact on PET spatial resolution. The distributions obtained were cusp-shaped with long tails rather than Gaussian shaped, thus making conventional full width at half maximum (FWHM) measures uncertain. The full width at 20% of the maximum amplitude (FW20M) of the annihilation distributions yielded more appropriate values for root mean square addition of spatial resolution loss components. Large differences in spatial resolution losses due to the positron flight in various human tissues were found for the selected radionuclides. The contribution to image blur was found to be up to three times larger in lung tissue than in soft tissue or fat and five times larger than in bone tissue. For {sup 18}F, the spatial resolution losses were 0.54 mm in soft tissue and 1.52 mm in lung tissue, compared with 4.10 and 10.5 mm, respectively, for {sup 82}Rb. With lung tissue as a possible exception, the image blur due to the positron flight in all human tissues has a minor impact as long as PET cameras with a spatial resolution of 5-7 mm are used in combination with {sup 18}F-labelled radiopharmaceuticals. However, when ultra-high spatial resolution PET cameras, with 3-4 mm spatial resolution, are applied, especially in combination with other radionuclides, the positron flight may enter as a limiting factor for the total PET spatial resolution - particularly in lung tissue. (orig.)

  5. Positron flight in human tissues and its influence on PET image spatial resolution

    International Nuclear Information System (INIS)

    Sanchez-Crespo, Alejandro; Larsson, Stig A.; Andreo, Pedro

    2004-01-01

    The influence of the positron distance of flight in various human tissues on the spatial resolution in positron emission tomography (PET) was assessed for positrons from carbon-11, nitrogen-13, oxygen-15, fluorine-18, gallium-68 and rubidium-82. The investigation was performed using the Monte Carlo code PENELOPE to simulate the transport of positrons within human compact bone, adipose, soft and lung tissue. The simulations yielded 3D distributions of annihilation origins that were projected on the image plane in order to assess their impact on PET spatial resolution. The distributions obtained were cusp-shaped with long tails rather than Gaussian shaped, thus making conventional full width at half maximum (FWHM) measures uncertain. The full width at 20% of the maximum amplitude (FW20M) of the annihilation distributions yielded more appropriate values for root mean square addition of spatial resolution loss components. Large differences in spatial resolution losses due to the positron flight in various human tissues were found for the selected radionuclides. The contribution to image blur was found to be up to three times larger in lung tissue than in soft tissue or fat and five times larger than in bone tissue. For 18 F, the spatial resolution losses were 0.54 mm in soft tissue and 1.52 mm in lung tissue, compared with 4.10 and 10.5 mm, respectively, for 82 Rb. With lung tissue as a possible exception, the image blur due to the positron flight in all human tissues has a minor impact as long as PET cameras with a spatial resolution of 5-7 mm are used in combination with 18 F-labelled radiopharmaceuticals. However, when ultra-high spatial resolution PET cameras, with 3-4 mm spatial resolution, are applied, especially in combination with other radionuclides, the positron flight may enter as a limiting factor for the total PET spatial resolution - particularly in lung tissue. (orig.)

  6. Guide to clinical PET in oncology: Improving clinical management of cancer patients

    International Nuclear Information System (INIS)

    2008-10-01

    information on clinical PET in oncology for nuclear medicine physicians, radiologists and clinical practitioners. Possible ideas for cost effectiveness of clinical PET in oncology are mentioned. The information is also intended to be useful in decision making to improve clinical management of cancer patients when allocating resources dedicated to the health care system. This is a critical issue that is important for the development of both clinical oncology and nuclear medicine in IAEA member states. The IAEA can be instrumental in the advancement of programmes which focus on the IAEA's coordinated research projects and technical cooperation project

  7. Performance study of a PET scanner based on monolithic scintillators for different DoI-dependent methods

    International Nuclear Information System (INIS)

    Preziosi, E.; Sánchez, S.; González, A.J.; Rodriguez-Alvarez, M.J.; González-Montoro, A.; Moliner, L.; Benlloch, J.M.; Pani, R.; Borrazzo, C.; Bettiol, M.

    2016-01-01

    One of the technical objectives of the MindView project is developing a brain-dedicated PET insert based on monolithic scintillation crystals. It will be inserted in MRI systems with the purpose to obtain simultaneous PET and MRI brain images. High sensitivity, high image quality performance and accurate detection of the Depth-of-Interaction (DoI) of the 511keV photons are required. We have developed a DoI estimation method, dedicated to monolithic scintillators, allowing continuous DoI estimation and a DoI-dependent algorithm for the estimation of the photon planar impact position, able to improve the single module imaging capabilities. In this work, through experimental measurements, the proposed methods have been used for the estimation of the impact positions within the monolithic crystal block. We have evaluated the PET system performance following the NEMA NU 4-2008 protocol by reconstructing the images using the STIR 3D platform. The results obtained with two different methods, providing discrete and continuous DoI information, are compared with those obtained from an algorithm without DoI capabilities and with the ideal response of the detector. The proposed DoI-dependent imaging methods show clear improvements in the spatial resolution (FWHM) of reconstructed images, allowing to obtain values from 2mm (at the center FoV) to 3mm (at the FoV edges).

  8. Comparison of PET/CT with Sequential PET/MRI Using an MR-Compatible Mobile PET System.

    Science.gov (United States)

    Nakamoto, Ryusuke; Nakamoto, Yuji; Ishimori, Takayoshi; Fushimi, Yasutaka; Kido, Aki; Togashi, Kaori

    2018-05-01

    The current study tested a newly developed flexible PET (fxPET) scanner prototype. This fxPET system involves dual arc-shaped detectors based on silicon photomultipliers that are designed to fit existing MRI devices, allowing us to obtain fused PET and MR images by sequential PET and MR scanning. This prospective study sought to evaluate the image quality, lesion detection rate, and quantitative values of fxPET in comparison with conventional whole-body (WB) PET and to assess the accuracy of registration. Methods: Seventeen patients with suspected or known malignant tumors were analyzed. Approximately 1 h after intravenous injection of 18 F-FDG, WB PET/CT was performed, followed by fxPET and MRI. For reconstruction of fxPET images, MRI-based attenuation correction was applied. The quality of fxPET images was visually assessed, and the number of detected lesions was compared between the 2 imaging methods. SUV max and maximum average SUV within a 1 cm 3 spheric volume (SUV peak ) of lesions were also compared. In addition, the magnitude of misregistration between fxPET and MR images was evaluated. Results: The image quality of fxPET was acceptable for diagnosis of malignant tumors. There was no significant difference in detectability of malignant lesions between fxPET and WB PET ( P > 0.05). However, the fxPET system did not exhibit superior performance to the WB PET system. There were strong positive correlations between the 2 imaging modalities in SUV max (ρ = 0.88) and SUV peak (ρ = 0.81). SUV max and SUV peak measured with fxPET were approximately 1.1-fold greater than measured with WB PET. The average misregistration between fxPET and MR images was 5.5 ± 3.4 mm. Conclusion: Our preliminary data indicate that running an fxPET scanner near an existing MRI system provides visually and quantitatively acceptable fused PET/MR images for diagnosis of malignant lesions. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  9. Comparison between PET/MR and PET/CT in evaluation of oncological patients%PET/MR与PET/CT的对比研究

    Institute of Scientific and Technical Information of China (English)

    徐白萱; 富丽萍; 关志伟; 尹大一; 刘家金; 杨晖; 张锦明; 陈英茂; 安宁豫

    2014-01-01

    Objective To verify the feasibility of the integrated PET/MR for oncological applications by comparing PET/MR with PET/CT in terms of lesion detection and quantitative measurement.Methods A total of 277 patients (165 males,112 females,average age (52.9± 12.6) years) voluntarily participated in this same-day PET/CT and PET/MR comparative study.The time interval between the two studies was 15-35 min.PET/CT images were acquired and reconstructed following standard protocols.PET/MR covered the body trunk with a sequence combination of transverse T1 weighted imaging (WI) 3D-volumetric interpolated breath-hold,T2WI turbo spin echo with fat saturation,diffusion-weighted imaging,and simultaneous PET acquisition.PET images were reconstructed by vender-provided attenuation correction methods.The results of PET/CT and PET/MR were regarded as positive if any modality (CT,PET or MRI) was positive.SUVmax was obtained by the manually drawn ROI.Detection rates were compared with x2 test and SUVmax from the two modalities was analyzed with Spearman correlation analysis.Results A total of 353 lesions were detected in 220 patients.Compared to PET/CT,PET/MR revealed 30 additional true-positive lesions,while missed 6.The detection rates between PET/CT and PET/MR were significantly different (P<0.05).The lesion-based and patient-based consistency was 89.8% (317/353) and 85.9% (189/220),respectively.There were significant correlations of SUVmax between PET/MR and PET/CT for lesions(rs =0.91,P<0.01) and for normal tissues(rs =0.62-0.76,all P<0.01).Conclusions With reference to PET/CT,integrated PET/MR may provide comparable semi-quantitative measurements of pathological lesions as well as normal tissues.Integrated PET/MR may be more effective to detect lesions in abdomen and pelvis.%目的 通过与PET/CT在病灶检测及定量分析方面的比较,论证PET/MR一体机应用于临床的可行性.方法 2012年5月至2013年2月共300例患者同天间隔15 ~ 35 min行PET/CT和PET

  10. High dynamic range adaptive real-time smart camera: an overview of the HDR-ARTiST project

    Science.gov (United States)

    Lapray, Pierre-Jean; Heyrman, Barthélémy; Ginhac, Dominique

    2015-04-01

    Standard cameras capture only a fraction of the information that is visible to the human visual system. This is specifically true for natural scenes including areas of low and high illumination due to transitions between sunlit and shaded areas. When capturing such a scene, many cameras are unable to store the full Dynamic Range (DR) resulting in low quality video where details are concealed in shadows or washed out by sunlight. The imaging technique that can overcome this problem is called HDR (High Dynamic Range) imaging. This paper describes a complete smart camera built around a standard off-the-shelf LDR (Low Dynamic Range) sensor and a Virtex-6 FPGA board. This smart camera called HDR-ARtiSt (High Dynamic Range Adaptive Real-time Smart camera) is able to produce a real-time HDR live video color stream by recording and combining multiple acquisitions of the same scene while varying the exposure time. This technique appears as one of the most appropriate and cheapest solution to enhance the dynamic range of real-life environments. HDR-ARtiSt embeds real-time multiple captures, HDR processing, data display and transfer of a HDR color video for a full sensor resolution (1280 1024 pixels) at 60 frames per second. The main contributions of this work are: (1) Multiple Exposure Control (MEC) dedicated to the smart image capture with alternating three exposure times that are dynamically evaluated from frame to frame, (2) Multi-streaming Memory Management Unit (MMMU) dedicated to the memory read/write operations of the three parallel video streams, corresponding to the different exposure times, (3) HRD creating by combining the video streams using a specific hardware version of the Devebecs technique, and (4) Global Tone Mapping (GTM) of the HDR scene for display on a standard LCD monitor.

  11. Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera.

    Science.gov (United States)

    Ben-Haim, Simona; Kacperski, Krzysztof; Hain, Sharon; Van Gramberg, Dean; Hutton, Brian F; Erlandsson, Kjell; Sharir, Tali; Roth, Nathaniel; Waddington, Wendy A; Berman, Daniel S; Ell, Peter J

    2010-08-01

    We compared simultaneous dual-radionuclide (DR) stress and rest myocardial perfusion imaging (MPI) with a novel solid-state cardiac camera and a conventional SPECT camera with separate stress and rest acquisitions. Of 27 consecutive patients recruited, 24 (64.5+/-11.8 years of age, 16 men) were injected with 74 MBq of (201)Tl (rest) and 250 MBq (99m)Tc-MIBI (stress). Conventional MPI acquisition times for stress and rest are 21 min and 16 min, respectively. Rest (201)Tl for 6 min and simultaneous DR 15-min list mode gated scans were performed on a D-SPECT cardiac scanner. In 11 patients DR D-SPECT was performed first and in 13 patients conventional stress (99m)Tc-MIBI SPECT imaging was performed followed by DR D-SPECT. The DR D-SPECT data were processed using a spill-over and scatter correction method. DR D-SPECT images were compared with rest (201)Tl D-SPECT and with conventional SPECT images by visual analysis employing the 17-segment model and a five-point scale (0 normal, 4 absent) to calculate the summed stress and rest scores. Image quality was assessed on a four-point scale (1 poor, 4 very good) and gut activity was assessed on a four-point scale (0 none, 3 high). Conventional MPI studies were abnormal at stress in 17 patients and at rest in 9 patients. In the 17 abnormal stress studies DR D-SPECT MPI showed 113 abnormal segments and conventional MPI showed 93 abnormal segments. In the nine abnormal rest studies DR D-SPECT showed 45 abnormal segments and conventional MPI showed 48 abnormal segments. The summed stress and rest scores on conventional SPECT and DR D-SPECT were highly correlated (r=0.9790 and 0.9694, respectively). The summed scores of rest (201)Tl D-SPECT and DR-DSPECT were also highly correlated (r=0.9968, pstress perfusion defects were significantly larger on stress DR D-SPECT images, and five of these patients were imaged earlier by D-SPECT than by conventional SPECT. Fast and high-quality simultaneous DR MPI is feasible with D-SPECT in a

  12. Pet Problems at Home: Pet Problems in the Community.

    Science.gov (United States)

    Soltow, Willow

    1984-01-01

    Discusses problems of pets in the community, examining the community's role related to disruptive pets and pet overpopulation. Also discusses pet problems at home, offering advice on selecting a pet, meeting a pet's needs, and disciplining pets. Includes a list of books, films/filmstrips, teaching materials, and various instructional strategies.…

  13. A fast algorithm for computer aided collimation gamma camera (CACAO)

    Science.gov (United States)

    Jeanguillaume, C.; Begot, S.; Quartuccio, M.; Douiri, A.; Franck, D.; Pihet, P.; Ballongue, P.

    2000-08-01

    The computer aided collimation gamma camera is aimed at breaking down the resolution sensitivity trade-off of the conventional parallel hole collimator. It uses larger and longer holes, having an added linear movement at the acquisition sequence. A dedicated algorithm including shift and sum, deconvolution, parabolic filtering and rotation is described. Examples of reconstruction are given. This work shows that a simple and fast algorithm, based on a diagonal dominant approximation of the problem can be derived. Its gives a practical solution to the CACAO reconstruction problem.

  14. The electronics system for the LBNL positron emission mammography (PEM) camera

    CERN Document Server

    Moses, W W; Baker, K; Jones, W; Lenox, M; Ho, M H; Weng, M

    2001-01-01

    Describes the electronics for a high-performance positron emission mammography (PEM) camera. It is based on the electronics for a human brain positron emission tomography (PET) camera (the Siemens/CTI HRRT), modified to use a detector module that incorporates a photodiode (PD) array. An application-specified integrated circuit (ASIC) services the photodetector (PD) array, amplifying its signal and identifying the crystal of interaction. Another ASIC services the photomultiplier tube (PMT), measuring its output and providing a timing signal. Field-programmable gate arrays (FPGAs) and lookup RAMs are used to apply crystal-by-crystal correction factors and measure the energy deposit and the interaction depth (based on the PD/PMT ratio). Additional FPGAs provide event multiplexing, derandomization, coincidence detection, and real-time rebinning. Embedded PC/104 microprocessors provide communication, real-time control, and configure the system. Extensive use of FPGAs make the overall design extremely flexible, all...

  15. F-18 FDG PET finding in autonomous thyroid nodules

    International Nuclear Information System (INIS)

    Park, Chan H.; Lee, Myoung Hoon; Yoon, Seek Nam; Hwang, Kyung Hoon

    2001-01-01

    F-18 FDG PET has become an important diagnostic imaging modality of various malignancies including thyroid cancer. Focal hypermetabolic lesion in the thyroid gland is usually considered malignant (Fig.1), although some benign lesions are also hypermetabolic. The aim of our poster presentation is to demonstrate F-18- FDG PET finding in autonomous thyroid nodules (ATN) and to avoid confusion in the interpretation of F-18-FDG PET performed for the evaluation of thyroid malignancy. Two patients with ATN (one with toxic and the other with nontoxic) underwent F-18-PET. ATN was proven by Tc-99m pertechnate thyroid scan (TS) and thyroid function tests (TFTs) were performed. First patient with ATN was asymptomatic and had a long history of thyroid nodule. Second patient was suffering from acute myelogenous leukemia (AML) and he was mildly thyrotoxic clinically and chemically. Gamma camera based F-18 FDG PET was performed utilizing Elscints Varicam (Haifa, Israel) one hour after IV administration of 111 MBq (3mCi) F-18 FDG. Patients were fasting more than 6 hours prior ot FDG injection. First patients was scanned the neck and second patient had scan of the whole trunk including neck for the evaluation of AML. Both nontoxic and toxic ATNs were hypermetabolic and it was impossible to differentiate benign from malignancy. Biopsy of nodule of the first patient and surgical removal of the nodule in the second patient was benign. Benign nontoxic and toxic ATNs are F-18 FDG avid. The reason for this is that ATN has increased glycolysis and iodide metabolism. Therefore, focal increased FDG uptake within the thyroid gland should be interpreted with TS and TFTs for an accurate diagnosis when F-18 FDG PET is used in the evaluation of thyroid malignancy

  16. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

    OpenAIRE

    Mustafa Demir; Türkay Toklu; Mohammad Abuqbeitah; Hüseyin Çetin; H. Sezer Sezgin; Nami Yeyin; Kerim Sönmezoğlu

    2018-01-01

    Objective: The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. Methods: According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated...

  17. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

    OpenAIRE

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H. Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-01-01

    Objective: The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. Methods: According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated asp...

  18. The impact of 18F-FDG PET/CT in patients with liver metastases

    International Nuclear Information System (INIS)

    Chua, Siew C.; Groves, Ashley M.; Kayani, Irfan; Menezes, Leon; Gacinovic, Svetislav; Du, Yong; Bomanji, Jamshed B.; Ell, Peter J.

    2007-01-01

    The aim of this study was to assess the performance of 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) versus dedicated contrast-enhanced CT (CECT) in the detection of metastatic liver disease. All patients that presented to our Institution with suspected metastatic liver disease who underwent 18 F-FDG PET/CT and CECT within 6 weeks of each other, were retrospectively analyzed, covering a 5-year period. One hundred and thirty-one patients (67 men, 64 women; mean age 62) were identified. Seventy-five had colorectal carcinoma and 56 had other malignancies. The performance of CECT and that of 18 F-FDG-PET/CT in detecting liver metastases were compared. The ability of each to detect local recurrence, extrahepatic metastases and to alter patient management was recorded. The final diagnosis was based on histology, clinical and radiological follow-up (mean 23 months). In detecting hepatic metastases, 18 F-FDG-PET/CT yielded 96% sensitivity and 75% specificity, whilst CECT showed 88% sensitivity and 25% specificity. 18 F-FDG-PET/CT and CECT were concordant in 102 out of 131 patients (78%). In the colorectal group 18 F-FDG-PET/CT showed 94% sensitivity and 75% specificity, whilst CECT had 91% sensitivity and 25% specificity. In the noncolorectal group 18 F-FDG-PET/CT showed 98% sensitivity and 75% specificity whilst CECT had 85% sensitivity and 25% specificity. Overall, 18 F-FDG-PET/CT altered patient management over CECT in 25% of patients. CECT did not alter patient management over 18 F-FDG-PET/CT alone in any patients. 18 F-FDG-PET/CT performed better in detecting metastatic liver disease than CECT in both colorectal and noncolorectal malignancies, and frequently altered patient management. The future role of CECT in these patients may need to be re-evaluated to avoid potentially unnecessary duplication of investigation where 18 F-PET/CT is readily available. (orig.)

  19. Direct comparison of {sup 18}F-FDG and {sup 11}C-methionine PET in suspected recurrence of glioma: sensitivity, inter-observer variability and prognostic value

    Energy Technology Data Exchange (ETDEWEB)

    Laere, Koen Van; Ceyssens, Sarah; Mortelmans, Luc [University Hospital Leuven, Division of Nuclear Medicine, Leuven (Belgium); Calenbergh, Frank Van [University Hospital Leuven, Department of Neurosurgery, Leuven (Belgium); Groot, Tjibbe de; Bormans, Guy [University Hospital Leuven, Laboratory of Radiopharmaceutical Chemistry, Leuven (Belgium); Menten, Johan [University Hospital Leuven, Division of Radiotherapy, Leuven (Belgium); Flamen, Patrick [University Hospital Leuven, Division of Nuclear Medicine, Leuven (Belgium); Bordet Hospital, Division of Nuclear Medicine, Brussels (Belgium)

    2005-01-01

    {sup 18}F-fluorodeoxyglucose (FDG) and {sup 11}C-methionine (MET) PET imaging studies allow the investigation of metabolism and amino acid transport in brain tumours. Their (relative) usefulness and prognostic value in suspected recurrence or progression of primary brain tumours after previous therapy is an issue of debate. The aim of this study was to compare directly both radioligands in this setting. Cerebral uptake of FDG and MET was determined sequentially on the same day in 30 patients (21 males, nine females; age 40.4{+-}15.6 years), on average 4.0 years (range 0.1-18) after therapy for a primary brain tumour (23 grade II-IV astrocytomas, four oligodendrogliomas and three mixed oligo-astrocytomas). Images were acquired on a Siemens HR+ dedicated PET camera. Two observers scored FDG and MET scans independently. Semi-quantitative indices defined by the tumour (maximum)-to-background ratio were calculated based on manual ROI delineation and by using MET ROIs for FDG after automated co-registration. Patient follow-up was conducted until the last contact with inconspicuous clinical findings (average 41 months, range 12-62 months after PET) [(n=10)] or until death (n=20). Overall median survival was 15.0 months. MET showed pathologically increased uptake in 28/30 scans, and FDG in 17/30. The inter-observer agreement was 100% for MET and 73% for FDG. Using Kaplan-Meier survival analysis, significant differences were found for both FDG (cut-off 0.8, log-rank p=0.007) and MET (cut-off 2.2, log-rank p=0.014). The combination of FDG and MET information resulted in the highest prognostic accuracy (p=0.003), while MET alone was the best prognostic predictor in the subgroup of patients with primary astrocytoma (n=23). FDG and MET PET studies provide complementary prognostic information in patients with suspected brain tumour recurrence or progression after primary therapy. MET is considered the single agent of choice in the evaluation of these patients because of its

  20. High-resolution dynamic imaging and quantitative analysis of lung cancer xenografts in nude mice using clinical PET/CT.

    Science.gov (United States)

    Wang, Ying Yi; Wang, Kai; Xu, Zuo Yu; Song, Yan; Wang, Chu Nan; Zhang, Chong Qing; Sun, Xi Lin; Shen, Bao Zhong

    2017-08-08

    Considering the general application of dedicated small-animal positron emission tomography/computed tomography is limited, an acceptable alternative in many situations might be clinical PET/CT. To estimate the feasibility of using clinical PET/CT with [F-18]-fluoro-2-deoxy-D-glucose for high-resolution dynamic imaging and quantitative analysis of cancer xenografts in nude mice. Dynamic clinical PET/CT scans were performed on xenografts for 60 min after injection with [F-18]-fluoro-2-deoxy-D-glucose. Scans were reconstructed with or without SharpIR method in two phases. And mice were sacrificed to extracting major organs and tumors, using ex vivo γ-counting as a reference. Strikingly, we observed that the image quality and the correlation between the all quantitive data from clinical PET/CT and the ex vivo counting was better with the SharpIR reconstructions than without. Our data demonstrate that clinical PET/CT scanner with SharpIR reconstruction is a valuable tool for imaging small animals in preclinical cancer research, offering dynamic imaging parameters, good image quality and accurate data quatification.

  1. Accuracy Potential and Applications of MIDAS Aerial Oblique Camera System

    Science.gov (United States)

    Madani, M.

    2012-07-01

    Airborne oblique cameras such as Fairchild T-3A were initially used for military reconnaissance in 30s. A modern professional digital oblique camera such as MIDAS (Multi-camera Integrated Digital Acquisition System) is used to generate lifelike three dimensional to the users for visualizations, GIS applications, architectural modeling, city modeling, games, simulators, etc. Oblique imagery provide the best vantage for accessing and reviewing changes to the local government tax base, property valuation assessment, buying & selling of residential/commercial for better decisions in a more timely manner. Oblique imagery is also used for infrastructure monitoring making sure safe operations of transportation, utilities, and facilities. Sanborn Mapping Company acquired one MIDAS from TrackAir in 2011. This system consists of four tilted (45 degrees) cameras and one vertical camera connected to a dedicated data acquisition computer system. The 5 digital cameras are based on the Canon EOS 1DS Mark3 with Zeiss lenses. The CCD size is 5,616 by 3,744 (21 MPixels) with the pixel size of 6.4 microns. Multiple flights using different camera configurations (nadir/oblique (28 mm/50 mm) and (50 mm/50 mm)) were flown over downtown Colorado Springs, Colorado. Boresight fights for 28 mm nadir camera were flown at 600 m and 1,200 m and for 50 mm nadir camera at 750 m and 1500 m. Cameras were calibrated by using a 3D cage and multiple convergent images utilizing Australis model. In this paper, the MIDAS system is described, a number of real data sets collected during the aforementioned flights are presented together with their associated flight configurations, data processing workflow, system calibration and quality control workflows are highlighted and the achievable accuracy is presented in some detail. This study revealed that the expected accuracy of about 1 to 1.5 GSD (Ground Sample Distance) for planimetry and about 2 to 2.5 GSD for vertical can be achieved. Remaining systematic

  2. ACCURACY POTENTIAL AND APPLICATIONS OF MIDAS AERIAL OBLIQUE CAMERA SYSTEM

    Directory of Open Access Journals (Sweden)

    M. Madani

    2012-07-01

    Full Text Available Airborne oblique cameras such as Fairchild T-3A were initially used for military reconnaissance in 30s. A modern professional digital oblique camera such as MIDAS (Multi-camera Integrated Digital Acquisition System is used to generate lifelike three dimensional to the users for visualizations, GIS applications, architectural modeling, city modeling, games, simulators, etc. Oblique imagery provide the best vantage for accessing and reviewing changes to the local government tax base, property valuation assessment, buying & selling of residential/commercial for better decisions in a more timely manner. Oblique imagery is also used for infrastructure monitoring making sure safe operations of transportation, utilities, and facilities. Sanborn Mapping Company acquired one MIDAS from TrackAir in 2011. This system consists of four tilted (45 degrees cameras and one vertical camera connected to a dedicated data acquisition computer system. The 5 digital cameras are based on the Canon EOS 1DS Mark3 with Zeiss lenses. The CCD size is 5,616 by 3,744 (21 MPixels with the pixel size of 6.4 microns. Multiple flights using different camera configurations (nadir/oblique (28 mm/50 mm and (50 mm/50 mm were flown over downtown Colorado Springs, Colorado. Boresight fights for 28 mm nadir camera were flown at 600 m and 1,200 m and for 50 mm nadir camera at 750 m and 1500 m. Cameras were calibrated by using a 3D cage and multiple convergent images utilizing Australis model. In this paper, the MIDAS system is described, a number of real data sets collected during the aforementioned flights are presented together with their associated flight configurations, data processing workflow, system calibration and quality control workflows are highlighted and the achievable accuracy is presented in some detail. This study revealed that the expected accuracy of about 1 to 1.5 GSD (Ground Sample Distance for planimetry and about 2 to 2.5 GSD for vertical can be achieved. Remaining

  3. PET/SPECT/CT multimodal imaging in a transgenic mouse model of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Boisgard, R.; Alberini, J.L.; Jego, B.; Siquier, K.; Theze, B.; Guillermet, S.; Tavitian, B. [Service Hospitalier Frederic Joliot, Institut d' Imagerie BioMedicale, CEA, 91 - Orsay (France); Inserm, U803, 91 - Orsay (France)

    2008-02-15

    Background. - In the therapy monitoring of breast cancer, conventional imaging methods include ultrasound, mammography, CT and MRI, which are essentially based on tumor size modifications. However these modifications represent a late consequence of the biological response and fail to differentiate scar or necrotic tissue from residual viable tumoral tissue. Therefore, a current objective is to develop tools able to predict early response to treatment. Positron Emission Tomography (PET) and Single Photon Emission Computerized Tomography (SPECT) are imaging modalities able to provide extremely sensitive quantitative molecular data and are widely used in humans and animals. Results. - Mammary epithelial cells of female transgenic mice expressing the polyoma middle T onco-protein (Py M.T.), undergo four distinct stages of tumour progression, from pre malignant to malignant stages. Stages are identifiable in the mammary tissue and can lead to the development of distant metastases Longitudinal studies by dynamic whole body acquisitions by multimodal imaging including PET, SPECT and Computed Tomography (CT) allow following the tumoral evolution in Py M.T. mice in comparison with the histopathological analysis. At four weeks of age, mammary hyperplasia was identified by histopathology, but no abnormalities were found by palpation or detected by PET with 2-deoxy-2-[{sup 18}F]fluoro-D-glucose. Such as in some human mammary cancers, the sodium iodide sym-porter (N.I.S.) in tumoral mammary epithelial cells is expressed in this mouse model. In order to investigate the expression of N.I.S. in the Py M.T. mice mammary tumours, [{sup 99m}Tc]TcO{sub 4} imaging was performed with a dedicated SPECT/CT system camera (B.I.O.S.P.A.C.E. Gamma Imager/CT). Local uptake of [{sup 99m}Tc]TcO{sub 4} was detected as early as four weeks of age. The efficacy of chemotherapy was evaluated in this mouse model using a conventional regimen (Doxorubicine, 100 mg/ kg) administered weekly from nine to

  4. 18F-FDG PET/CT for early detection of embolism and metastatic infection in patients with infective endocarditis

    International Nuclear Information System (INIS)

    Riet, Jelle van; Gheysens, Olivier; Mortelmans, Luc; Hill, Evelyn E.; Herregods, Marie-Christine; Dymarkowski, Steven; Herijgers, Paul; Peetermans, Willy E.

    2010-01-01

    In the acute setting of endocarditis it is very important to assess both the vegetation itself, as well as potential life-threatening complications, in order to decide whether antibiotic therapy will be sufficient or urgent surgery is indicated. A single whole-body scan investigating inflammatory changes could be very helpful to achieve a swift and efficient assessment. In this study we assessed whether 18 F-FDG can be used to detect and localize peripheral embolism or distant infection. Twenty-four patients with 25 episodes of endocarditis, enrolled between March 2006 and February 2008, underwent 18 F-FDG PET/CT imaging on a dedicated PET/CT scanner. PET/CT imaging revealed a focus of peripheral embolization and/or metastatic infection in 11 episodes (44%). One episode had a positive PET/CT scan result for both embolism and metastatic infection. PET/CT detected seven positive cases (28%) in which there was no clinical suspicion. Valve involvement of endocarditis was seen only in three patients (12%). PET/CT may be an important diagnostic tool for tracing peripheral embolism and metastatic infection in the acute setting of infective endocarditis, since a PET/CT scan detected a clinically occult focus in nearly one third of episodes. (orig.)

  5. Iterative reconstruction using a Monte Carlo based system transfer matrix for dedicated breast positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Krishnendu [Ohio Medical Physics Consulting, Dublin, Ohio 43017 (United States); Straus, Kenneth J.; Glick, Stephen J. [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States); Chen, Yu. [Department of Radiation Oncology, Columbia University, New York, New York 10032 (United States)

    2014-08-28

    To maximize sensitivity, it is desirable that ring Positron Emission Tomography (PET) systems dedicated for imaging the breast have a small bore. Unfortunately, due to parallax error this causes substantial degradation in spatial resolution for objects near the periphery of the breast. In this work, a framework for computing and incorporating an accurate system matrix into iterative reconstruction is presented in an effort to reduce spatial resolution degradation towards the periphery of the breast. The GATE Monte Carlo Simulation software was utilized to accurately model the system matrix for a breast PET system. A strategy for increasing the count statistics in the system matrix computation and for reducing the system element storage space was used by calculating only a subset of matrix elements and then estimating the rest of the elements by using the geometric symmetry of the cylindrical scanner. To implement this strategy, polar voxel basis functions were used to represent the object, resulting in a block-circulant system matrix. Simulation studies using a breast PET scanner model with ring geometry demonstrated improved contrast at 45% reduced noise level and 1.5 to 3 times resolution performance improvement when compared to MLEM reconstruction using a simple line-integral model. The GATE based system matrix reconstruction technique promises to improve resolution and noise performance and reduce image distortion at FOV periphery compared to line-integral based system matrix reconstruction.

  6. A PET system based on 2-18FDG production with a low energy electrostatic proton accelerator and a dual headed PET scanner.

    Science.gov (United States)

    Sandell, A; Ohlsson, T; Erlandsson, K; Hellborg, R; Strand, S E

    1992-01-01

    We have developed a comparatively inexpensive PET system, based on a rotating scanner with two scintillation camera heads, and a nearby low energy electrostatic proton accelerator for production of short-lived radionuclides. Using a 6 MeV proton beam of 5 microA, and by optimization of the target geometry for the 18O(p,n)18F reaction, 750 MBq of 2-18FDG can be obtained. The PET scanner shows a spatial resolution of 6 mm (FWHM) and a sensitivity of 80 s-1kBq-1ml-1 (3 kcps/microCi/ml). Various corrections are included in the imaging process, to compensate for spatial and temporal response variations in the detector system. Both filtered backprojection and iterative reconstruction methods are employed. Clinical studies have been performed with acquisition times of 30-40 min. The system will be used for clinical experimental research with short- as well as long-lived positron emitters. Also the possibility of true 3D reconstruction is under evaluation.

  7. Intraindividual comparison of F-18-FLT PET and F-18 FET PET in brain tumor patients

    International Nuclear Information System (INIS)

    Kim, Sung Eun; Cheon, G. J.; Cho, Y. S.; Kwak, H. S.; Lee, C. H.; Choi, C. W.; Lim, S. M.

    2003-01-01

    To compare findings on FLT PET with FET PET, we prospectively undertaken FLT, FET and FDG PET in same patient with suspected primary/metastatic and recurrent brain tumors. Seventeen studies in 16 patients (47 8.3 years, M: F 10: 6) with brain tumor (3 for initial diagnosis, 6 for therapeutic response, 6 for detecting recurrence, 1 for diagnosis and recurrence both) were included. Brain tumors were 14 gliomas (6 high- grade 9 low-grade by the WHO classification), 2 metastatic brain tumors and 1 CNS lymphoma. 18F-FDG, FLT and FET PET were performed within two weeks. Attenuation-corrected brain images were acquired 30 minutes after injection of 370-555 MBq FDG, FLT and FET with a dedicated PET scanner (ECAT HR scanner, Siemens-CTI). Maximum SUV (max SUV) and relative uptake defined by FLT and FET accumulation within the tumor in relation to a contralateral control region (max SUV for tumor/ mean SUV for contralateral normal gray matter) were calculated. 26 tumor foci were analyzed. Relative FLT uptake (4.17 2.4, 0.58 to 7.45) was grater than than FET uptake (2.03 1.17, 0.92 to 4.53 (p<0.0006)) and FDG uptake (1.16 0.34, 0.76 to 2.08). Among FLT, FET and FDG uptakes in 20 tumor foci, correlation were poor. the relative FLT uptake of high-grade glioma was higher than low-glioma (6.070.76 vs 3.11 2.15, p=0.002), however, relative FET uptake was not different significantly (2.68 1.51, high-grade vs 1.970.78, low-grade). The correlation between tumor grade (high vs low grade) and relative uptake (FLT and FET) was shown only with relative FLT uptake (r=0.62, p=0.002). The best cut off value of relative FLT uptake between high-grade and low-grade glioma was 4.54 (AUC: 0.89 sensitivity: 100 specificity: 86.7%). Compared with FET uptake, FLT uptake showed much higher contrast and associated with tumor grade. Further study, evaluation of proliferative index of Ki-67 and its relationship with FLT and FET uptake, are ongoing

  8. Musculoskeletal MRI: dedicated systems

    International Nuclear Information System (INIS)

    Masciocchi, C.; Barile, A.; Satragno, L.

    2000-01-01

    The ''dedicated'' MRI units have characteristics of high diagnostic accuracy and lower installation and management costs as compared with whole-body systems. The dedicated MRI units are easy to install. The low weight allows their installation also under unfavorable circumstances. In a dedicated system cost-effectiveness and ease of installation must be accompanied by the capability of providing high-quality images. In our experience, the high number of examinations performed, the most part of which provided with the surgical controls, allowed an accurate evaluation of the diagnostic potentialities of the dedicated magnet. We were not able to perform the examinations in only 3 % of cases due to the physical shape of the patient and the clinical condition of the patient which may hinder the correct positioning of the limb. The overlapping of the diagnostic accuracy of the E-scan and Artoscan units in the study of the lower limbs, compared with whole-body units and surgery, prompted us to exploit the potentialities of the E-Scan in the study of the shoulder. We had a good correlation between E-Scan, whole-body units, and surgical findings, which confirmed the high diagnostic accuracy of the dedicated system. In conclusion, in our experience carried out in the musculoskeletal system, the dedicated magnets showed promising results. Their diagnostic reliability and utility was comparable to that obtained from conventional units operating at higher magnetic fields. (orig.)

  9. Strategies of statistical windows in PET image reconstruction to improve the user’s real time experience

    Science.gov (United States)

    Moliner, L.; Correcher, C.; Gimenez-Alventosa, V.; Ilisie, V.; Alvarez, J.; Sanchez, S.; Rodríguez-Alvarez, M. J.

    2017-11-01

    Nowadays, with the increase of the computational power of modern computers together with the state-of-the-art reconstruction algorithms, it is possible to obtain Positron Emission Tomography (PET) images in practically real time. These facts open the door to new applications such as radio-pharmaceuticals tracking inside the body or the use of PET for image-guided procedures, such as biopsy interventions, among others. This work is a proof of concept that aims to improve the user experience with real time PET images. Fixed, incremental, overlapping, sliding and hybrid windows are the different statistical combinations of data blocks used to generate intermediate images in order to follow the path of the activity in the Field Of View (FOV). To evaluate these different combinations, a point source is placed in a dedicated breast PET device and moved along the FOV. These acquisitions are reconstructed according to the different statistical windows, resulting in a smoother transition of positions for the image reconstructions that use the sliding and hybrid window.

  10. PET/CT-guided biopsies of metabolically active bone lesions: applications and clinical impact

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, Bernd; Wartenberg, Jan; Weitzel, Thilo; Krause, Thomas [Bern University Hospital and University of Bern, Department of Nuclear Medicine, Inselspital, Bern (Switzerland); Wiskirchen, Jakub [Bern University Hospital and University of Bern, Department of Nuclear Medicine, Inselspital, Bern (Switzerland); University Hospital Tuebingen, Department of Radiology, Neuroradiology, and Nuclear Medicine, Tuebingen (Germany); Schmid, Ralph A. [Bern University Hospital and University of Bern, Department of Thoracic Surgery, Inselspital, Bern (Switzerland); Mueller, Michel D. [Bern University Hospital and University of Bern, Department of Obstetrics and Gynaecology, Inselspital, Bern (Switzerland)

    2010-11-15

    In a minority of cases a definite diagnosis and stage grouping in cancer patients is not possible based on the imaging information of PET/CT. We report our experience with percutaneous PET/CT-guided bone biopsies to histologically verify the aetiology of hypermetabolic bone lesions. We retrospectively reviewed the data of 20 consecutive patients who underwent multimodal image-guided bone biopsies using a dedicated PET/CT system in a step-by-step technique. Technical and clinical success rates of PET/CT-guided biopsies were evaluated. Questionnaires were sent to the referring physicians to assess the impact of biopsies on patient management and to check the clinical need for PET/CT-guided biopsies. Clinical indications for biopsy were to histologically verify the aetiology of metabolically active bone lesions without a morphological correlate confirming the suspicion of metastases in 15 patients, to determine the origin of suspected metastases in 3 patients and to evaluate the appropriateness of targeted therapy options in 2 patients. Biopsies were technically successful in all patients. In 19 of 20 patients a definite histological diagnosis was possible. No complications or adverse effects occurred. The result of PET/CT-guided bone biopsies determined a change of the planned treatment in overall 56% of patients, with intramodality changes, e.g. chemotherapy with palliative instead of curative intent, and intermodality changes, e.g. systemic therapy instead of surgery, in 22 and 50%, respectively. PET/CT-guided bone biopsies are a promising alternative to conventional techniques to make metabolically active bone lesions - especially without a distinctive morphological correlate - accessible for histological verification. PET/CT-guided biopsies had a major clinical impact in patients who otherwise cannot be reliably stage grouped at the time of treatment decisions. (orig.)

  11. The motivations and methodology for high-throughput PET imaging of small animals in cancer research

    Energy Technology Data Exchange (ETDEWEB)

    Aide, Nicolas [Francois Baclesse Cancer Centre, Nuclear Medicine Department, Caen Cedex (France); Caen University, BioTICLA team, EA 4656, IFR 146, Caen (France); Visser, Eric P. [Radboud University Nijmegen Medical Center, Nuclear Medicine Department, Nijmegen (Netherlands); Lheureux, Stephanie [Caen University, BioTICLA team, EA 4656, IFR 146, Caen (France); Francois Baclesse Cancer Centre, Clinical Research Unit, Caen (France); Heutte, Natacha [Francois Baclesse Cancer Centre, Clinical Research Unit, Caen (France); Szanda, Istvan [King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom); Hicks, Rodney J. [Peter MacCallum Cancer Centre, Centre for Molecular Imaging, East Melbourne (Australia)

    2012-09-15

    Over the last decade, small-animal PET imaging has become a vital platform technology in cancer research. With the development of molecularly targeted therapies and drug combinations requiring evaluation of different schedules, the number of animals to be imaged within a PET experiment has increased. This paper describes experimental design requirements to reach statistical significance, based on the expected change in tracer uptake in treated animals as compared to the control group, the number of groups that will be imaged, and the expected intra-animal variability for a given tracer. We also review how high-throughput studies can be performed in dedicated small-animal PET, high-resolution clinical PET systems and planar positron imaging systems by imaging more than one animal simultaneously. Customized beds designed to image more than one animal in large-bore small-animal PET scanners are described. Physics issues related to the presence of several rodents within the field of view (i.e. deterioration of spatial resolution and sensitivity as the radial and the axial offsets increase, respectively, as well as a larger effect of attenuation and the number of scatter events), which can be assessed by using the NEMA NU 4 image quality phantom, are detailed. (orig.)

  12. Automatic inference of geometric camera parameters and inter-camera topology in uncalibrated disjoint surveillance cameras

    Science.gov (United States)

    den Hollander, Richard J. M.; Bouma, Henri; Baan, Jan; Eendebak, Pieter T.; van Rest, Jeroen H. C.

    2015-10-01

    Person tracking across non-overlapping cameras and other types of video analytics benefit from spatial calibration information that allows an estimation of the distance between cameras and a relation between pixel coordinates and world coordinates within a camera. In a large environment with many cameras, or for frequent ad-hoc deployments of cameras, the cost of this calibration is high. This creates a barrier for the use of video analytics. Automating the calibration allows for a short configuration time, and the use of video analytics in a wider range of scenarios, including ad-hoc crisis situations and large scale surveillance systems. We show an autocalibration method entirely based on pedestrian detections in surveillance video in multiple non-overlapping cameras. In this paper, we show the two main components of automatic calibration. The first shows the intra-camera geometry estimation that leads to an estimate of the tilt angle, focal length and camera height, which is important for the conversion from pixels to meters and vice versa. The second component shows the inter-camera topology inference that leads to an estimate of the distance between cameras, which is important for spatio-temporal analysis of multi-camera tracking. This paper describes each of these methods and provides results on realistic video data.

  13. Dedication

    OpenAIRE

    2013-01-01

    This work is dedicated, to my mom, Bridget, and my dad, (the late) Daniel Enwerem, who taught me to respect people but not fear them; and to those who are engaged or have been victims in the struggle for an egalitarian society in Nigeria.

  14. {sup 18}F-FDG PET/CT for early detection of embolism and metastatic infection in patients with infective endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Riet, Jelle van; Gheysens, Olivier; Mortelmans, Luc [University Hospital KU Leuven, Department of Nuclear Medicine, Leuven (Belgium); Hill, Evelyn E.; Herregods, Marie-Christine [University Hospital KU Leuven, Department of Cardiology, Leuven (Belgium); Dymarkowski, Steven [University Hospital KU Leuven, Department of Radiology, Leuven (Belgium); Herijgers, Paul [University Hospital KU Leuven, Department of Cardiac Surgery, Leuven (Belgium); Peetermans, Willy E. [University Hospital KU Leuven, Department of Internal Medicine, Leuven (Belgium)

    2010-06-15

    In the acute setting of endocarditis it is very important to assess both the vegetation itself, as well as potential life-threatening complications, in order to decide whether antibiotic therapy will be sufficient or urgent surgery is indicated. A single whole-body scan investigating inflammatory changes could be very helpful to achieve a swift and efficient assessment. In this study we assessed whether {sup 18}F-FDG can be used to detect and localize peripheral embolism or distant infection. Twenty-four patients with 25 episodes of endocarditis, enrolled between March 2006 and February 2008, underwent {sup 18}F-FDG PET/CT imaging on a dedicated PET/CT scanner. PET/CT imaging revealed a focus of peripheral embolization and/or metastatic infection in 11 episodes (44%). One episode had a positive PET/CT scan result for both embolism and metastatic infection. PET/CT detected seven positive cases (28%) in which there was no clinical suspicion. Valve involvement of endocarditis was seen only in three patients (12%). PET/CT may be an important diagnostic tool for tracing peripheral embolism and metastatic infection in the acute setting of infective endocarditis, since a PET/CT scan detected a clinically occult focus in nearly one third of episodes. (orig.)

  15. The MINDView brain PET detector, feasibility study based on SiPM arrays

    Energy Technology Data Exchange (ETDEWEB)

    González, Antonio J., E-mail: agonzalez@i3m.upv.es [Institute for Instrumentation in Molecular Imaging (I3M), 46022 Valencia (Spain); Majewski, Stan [Radiology Research, Department of Radiology, University of Virginia, VA 22903 (United States); Sánchez, Filomeno [Institute for Instrumentation in Molecular Imaging (I3M), 46022 Valencia (Spain); Aussenhofer, Sebastian [NORAS MRI products GmbH, Hochberg (Germany); Aguilar, Albert; Conde, Pablo; Hernández, Liczandro; Vidal, Luis F. [Institute for Instrumentation in Molecular Imaging (I3M), 46022 Valencia (Spain); Pani, Roberto; Bettiol, Marco; Fabbri, Andrea [Department of Molecular Medicine, Sapienza University of Rome (Italy); Bert, Julien; Visvikis, Dimitris [Université de Bretagne Occidentale, Brest (France); Jackson, Carl; Murphy, John; O’Neill, Kevin [SensL Technologies, Cork (Ireland); Benlloch, Jose M. [Institute for Instrumentation in Molecular Imaging (I3M), 46022 Valencia (Spain)

    2016-05-11

    The Multimodal Imaging of Neurological Disorders (MINDView) project aims to develop a dedicated brain Positron Emission Tomography (PET) scanner with sufficient resolution and sensitivity to visualize neurotransmitter pathways and their disruptions in mental disorders for diagnosis and follow-up treatment. The PET system should be compact and fully compatible with a Magnetic Resonance Imaging (MRI) device in order to allow its operation as a PET brain insert in a hybrid imaging setup with most MRI scanners. The proposed design will enable the currently-installed MRI base to be easily upgraded to PET/MRI systems. The current design for the PET insert consists of a 3-ring configuration with 20 modules per ring and an axial field of view of ~15 cm and a geometrical aperture of ~33 cm in diameter. When coupled to the new head Radio Frequency (RF) coil, the inner usable diameter of the complete PET-RF coil insert is reduced to 26 cm. Two scintillator configurations have been tested, namely a 3-layer staggered array of LYSO with 1.5 mm pixel size, with 35×35 elements (6 mm thickness each) and a black-painted monolithic LYSO block also covering about 50×50 mm{sup 2} active area with 20 mm thickness. Laboratory test results associated with the current MINDView PET module concept are presented in terms of key parameters' optimization, such as spatial and energy resolution, sensitivity and Depth of Interaction (DOI) capability. It was possible to resolve all pixel elements from the three scintillator layers with energy resolutions as good as 10%. The monolithic scintillator showed average detector resolutions varying from 3.5 mm in the entrance layer to better than 1.5 mm near the photosensor, with average energy resolutions of about 17%.

  16. Hybrid imaging (SPECT/CT, PET/CT) in differentiated thyroid cancer; Imagerie hybride (TEMP/TDM, TEP/TDM) et cancer differencie de la thyroide

    Energy Technology Data Exchange (ETDEWEB)

    Bardet, S.; Ciappuccini, R.; Aide, N. [Unite de concertation pluridisciplinaire thyroide, service de medecine nucleaire, centre Francois-Baclesse, 14 - Caen (France); Barraux, V. [Unite de radiophysique, centre Francois-Baclesse, 14 - Caen (France); Rame, J.P. [Chirurgie ORL, centre Francois-Baclesse, 14 - Caen (France)

    2010-08-15

    Differentiated thyroid cancer (DTC) is generally associated with a good prognosis. Local recurrences, mainly lymph-node involvement, account for 15-20% of cases and are surgically treated. Distant metastases, mostly in lungs and more rarely in bones, are present in 5% of patients. When iodine uptake is sufficient (in approximately 60% of patients), distant metastases can be destroyed by iterative activities of iodine 131. Serum thyroglobulin (Tg), which can be assessed either on hormonal treatment or on TSH stimulation is considered as the tumour marker in DTC. Functional (iodine 131 scintigraphy, FDG PET, bone scintigraphy) or anatomical (neck ultrasound, thoracic CT, bone MRI) imaging methods can be performed when Tg increases in order to show residual/recurrent disease. In recent years, new hybrid equipments integrating both a gamma camera and CT scan (SPECT/CT) have been commercialized while positron emission tomography cameras associated with CT (PET/CT) have been installed on the whole French territory. These equipments, which allow us to directly correlate functional and anatomical images, greatly improve the interpretation of planar scintigraphy or that of PET alone. Hybrid imaging enables us to precisely localize scintigraphic foci and most often, to immediately verify whether they correspond to tumour lesions. The aim of this article is to review the role of SPECT/CT and PET/CT in the management of patients with DTC in 2010. (authors)

  17. Fast image reconstruction for Compton camera using stochastic origin ensemble approach.

    Science.gov (United States)

    Andreyev, Andriy; Sitek, Arkadiusz; Celler, Anna

    2011-01-01

    Compton camera has been proposed as a potential imaging tool in astronomy, industry, homeland security, and medical diagnostics. Due to the inherent geometrical complexity of Compton camera data, image reconstruction of distributed sources can be ineffective and/or time-consuming when using standard techniques such as filtered backprojection or maximum likelihood-expectation maximization (ML-EM). In this article, the authors demonstrate a fast reconstruction of Compton camera data using a novel stochastic origin ensembles (SOE) approach based on Markov chains. During image reconstruction, the origins of the measured events are randomly assigned to locations on conical surfaces, which are the Compton camera analogs of lines-of-responses in PET. Therefore, the image is defined as an ensemble of origin locations of all possible event origins. During the course of reconstruction, the origins of events are stochastically moved and the acceptance of the new event origin is determined by the predefined acceptance probability, which is proportional to the change in event density. For example, if the event density at the new location is higher than in the previous location, the new position is always accepted. After several iterations, the reconstructed distribution of origins converges to a quasistationary state which can be voxelized and displayed. Comparison with the list-mode ML-EM reveals that the postfiltered SOE algorithm has similar performance in terms of image quality while clearly outperforming ML-EM in relation to reconstruction time. In this study, the authors have implemented and tested a new image reconstruction algorithm for the Compton camera based on the stochastic origin ensembles with Markov chains. The algorithm uses list-mode data, is parallelizable, and can be used for any Compton camera geometry. SOE algorithm clearly outperforms list-mode ML-EM for simple Compton camera geometry in terms of reconstruction time. The difference in computational time

  18. Comparison of lesion detection and quantitation of tracer uptake between PET from a simultaneously acquiring whole-body PET/MR hybrid scanner and PET from PET/CT

    International Nuclear Information System (INIS)

    Wiesmueller, Marco; Schmidt, Daniela; Beck, Michael; Kuwert, Torsten; Gall, Carl C. von; Quick, Harald H.; Navalpakkam, Bharath; Lell, Michael M.; Uder, Michael; Ritt, Philipp

    2013-01-01

    PET/MR hybrid scanners have recently been introduced, but not yet validated. The aim of this study was to compare the PET components of a PET/CT hybrid system and of a simultaneous whole-body PET/MR hybrid system with regard to reproducibility of lesion detection and quantitation of tracer uptake. A total of 46 patients underwent a whole-body PET/CT scan 1 h after injection and an average of 88 min later a second scan using a hybrid PET/MR system. The radioactive tracers used were 18 F-deoxyglucose (FDG), 18 F-ethylcholine (FEC) and 68 Ga-DOTATATE (Ga-DOTATATE). The PET images from PET/CT (PET CT ) and from PET/MR (PET MR ) were analysed for tracer-positive lesions. Regional tracer uptake in these foci was quantified using volumes of interest, and maximal and average standardized uptake values (SUV max and SUV avg , respectively) were calculated. Of the 46 patients, 43 were eligible for comparison and statistical analysis. All lesions except one identified by PET CT were identified by PET MR (99.2 %). In 38 patients (88.4 %), the same number of foci were identified by PET CT and by PET MR . In four patients, more lesions were identified by PET MR than by PET CT , in one patient PET CT revealed an additional focus compared to PET MR . The mean SUV max and SUV avg of all lesions determined by PET MR were by 21 % and 11 % lower, respectively, than the values determined by PET CT (p CT and PET MR were minor, but statistically significant. Nevertheless, a more detailed study of the quantitative accuracy of PET MR and the factors governing it is needed to ultimately assess its accuracy in measuring tissue tracer concentrations. (orig.)

  19. Design and performance of an acquisition and control system for a positron camera with novel detectors

    International Nuclear Information System (INIS)

    Symonds-Tayler, J.R.N.; Reader, A.J.; Flower, M.A.

    1996-01-01

    A Sun-based data acquisition and control (DAQ) system has been designed for PETRRA, a whole-body positron camera using large-area BaF 2 -TMAE detectors. The DAQ system uses a high-speed digital I/O card (S16D) installed on the S-bus of a SPARC10 and a specially-designed Positron Camera Interface (PCI), which also controls both the gantry and horizontal couch motion. Data in the form of different types of 6-byte packets are acquired in list mode. Tests with a signal generator show that the DAQ system should be able to cater for coincidence count-rates up to 100 kcps. The predicted count loss due to the DAQ system is ∼13% at this count rate, provided asynchronous-read based software is used. The list-mode data acquisition system designed for PETRRA could be adapted for other 3D PET cameras with similar data rates

  20. Simulation Study of PET System Using GATE%基于GATE的PET系统仿真研究

    Institute of Scientific and Technical Information of China (English)

    刘豪佳; 张斌

    2014-01-01

    PET and SPECT is the most advanced nuclear medical imaging technology .GATE is a dedicated Monte Carlo simulation platform for PET and SPECT .This study validates two GATE models of Simens ECAT EXACT HR+PET scanner and Simens PET/CT Biograph 2.After the simulation of PET systems completed , testing and performance evaluation of simulation systems were proceeded according to NEMA 2001 performance protocols , including spatial resolution , scatter fraction and sensitivity .Test results show that , performances of GATE simulation systems agree well with the experimental values .%PET和SPECT是现代核医学最高水平的影像技术,GATE是专用于PET和SPECT的蒙特卡罗仿真工具。研究以西门子公司的PET扫描仪 ECAT EXACT HR+和PET/CT Biograph2为原型,分别使用GATE实现其系统的完整仿真。依据NEMA 2001标准,对仿真系统的空间分辨率、散射分数和灵敏度分别进行测试与评估。测试结果表明,仿真系统性能参数和实验结果之间具有良好的一致性。

  1. Temporal lobe dysfunction in childhood autism: a PET study; Dysfonctionnement bitemporal dans l'autisme infantile: etude en tomographie par emission de positons

    Energy Technology Data Exchange (ETDEWEB)

    Boddaert, N; Poline, J B; Brunelle, F; Zilbovicius, M [Service Hospitalier Frederic Joliot, ER-M INSERM 0205, DSV, DRM CEA, 91 - Orsay (France); Brunelle, F [Centre Hospitalier Universitaire Necker-Enfants-Malades, Service de Radiologie Pediatrique, 75 - Paris (France); Chabane, N [Hopital Robert-Debre, Service de Pedopsychiatrie, 75 - Paris (France); Barthelemy, C; Zilbovicius, M [Centre Hospitalier Universitaire Bretonneau, INSERM Unite 316, 37 - Tours (France); Bourgeois, M [Centre Hospitalier Universitaire Necker-Enfants-Malades, Dept. de Pediatrie, 75 - Paris (France); Samson, Y [Centre Hospitalier Universitaire Pitie-Salpetriere, Service des Urgences Cerebraux Vasculaires, 75 - Paris (France)

    2002-12-01

    Childhood autism is a severe developmental disorder that impairs the acquisition of some of the most important skills in human life. Progress in understanding the neural basis of childhood autism requires clear and reliable data indicating specific neuro-anatomical or neuro-physiological abnormalities. The purpose of the present study was to research localized brain dysfunction in autistic children using functional brain imaging. Regional cerebral blood flow (rCBF) was measured with positron emission tomography (PET) in 21 primary autistic children and 10 age-matched non autistic children. A statistical parametric analysis of rCBF images revealed significant bilateral temporal hypoperfusion in the associative auditory cortex (superior temporal gyrus) and in the multimodal cortex (superior temporal sulcus) in the autistic group (p<0.001). In addition, temporal hypoperfusion was detected individually in 77% of autistic children. These findings provide robust evidence of well localized functional abnormalities in autistic children located in the superior temporal lobe. Such localized abnormalities were not detected with the low resolution PET camera (14-22). This study suggests that high resolution PET camera combined with statistical parametric mapping is useful to understand developmental disorders. (authors)

  2. Single software platform used for high speed data transfer implementation in a 65k pixel camera working in single photon counting mode

    International Nuclear Information System (INIS)

    Maj, P.; Kasiński, K.; Gryboś, P.; Szczygieł, R.; Kozioł, A.

    2015-01-01

    Integrated circuits designed for specific applications generally use non-standard communication methods. Hybrid pixel detector readout electronics produces a huge amount of data as a result of number of frames per seconds. The data needs to be transmitted to a higher level system without limiting the ASIC's capabilities. Nowadays, the Camera Link interface is still one of the fastest communication methods, allowing transmission speeds up to 800 MB/s. In order to communicate between a higher level system and the ASIC with a dedicated protocol, an FPGA with dedicated code is required. The configuration data is received from the PC and written to the ASIC. At the same time, the same FPGA should be able to transmit the data from the ASIC to the PC at the very high speed. The camera should be an embedded system enabling autonomous operation and self-monitoring. In the presented solution, at least three different hardware platforms are used—FPGA, microprocessor with real-time operating system and the PC with end-user software. We present the use of a single software platform for high speed data transfer from 65k pixel camera to the personal computer

  3. Single software platform used for high speed data transfer implementation in a 65k pixel camera working in single photon counting mode

    Science.gov (United States)

    Maj, P.; Kasiński, K.; Gryboś, P.; Szczygieł, R.; Kozioł, A.

    2015-12-01

    Integrated circuits designed for specific applications generally use non-standard communication methods. Hybrid pixel detector readout electronics produces a huge amount of data as a result of number of frames per seconds. The data needs to be transmitted to a higher level system without limiting the ASIC's capabilities. Nowadays, the Camera Link interface is still one of the fastest communication methods, allowing transmission speeds up to 800 MB/s. In order to communicate between a higher level system and the ASIC with a dedicated protocol, an FPGA with dedicated code is required. The configuration data is received from the PC and written to the ASIC. At the same time, the same FPGA should be able to transmit the data from the ASIC to the PC at the very high speed. The camera should be an embedded system enabling autonomous operation and self-monitoring. In the presented solution, at least three different hardware platforms are used—FPGA, microprocessor with real-time operating system and the PC with end-user software. We present the use of a single software platform for high speed data transfer from 65k pixel camera to the personal computer.

  4. Clinical value of FDG hybrid-PET in staging and restaging of malignant lymphoma. Compared with conventional diagnostic methods; Klinische Wertigkeit der Befunde von FDG-PET mittels Koinzidenz-Gammakamera beim Staging und Restaging maligner Lymphome. Ein Vergleich zu konventioneller Diagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Pichler, R.; Maschek, W.; Hatzl-Griesenhofer, M.; Huber, H. [Allgemeines Krankenhaus Linz (Austria). Inst. fuer Nuklearmedizin; Wimmer, G.; Wahl, G.; Fridrik, M. [Allgemeines Krankenhaus Linz (Austria). I. Medizinische Abt.

    2000-09-01

    Aim of the present retrospective study was to validate the clinical value of F-18-FDG PET imaging in lymphoma patients with a dual head camera modified for coincidence detection. Staging before and after oncological treatment was compared with a conservative diagnostic approach. Methods: 48 patients (28 non-Hodgkin lymphoma, 20 Hodgkin's disease) received FDG-Hybrid-PET scans. Pretherapeutic staging was realized in 28 patients, 9 of them had control studies after they had completed therapy. Totally 29 persons were examined for posttherapeutic restaging. Computed tomography imaging and lymph node sonography was performed in all cases. Results were validated by clinical follow-up, in three cases a recidive was proven by biopsy. Results: CT and ultrasound detected 77 lesions in 28 patients compared with 100 visualized by PET, but this difference in pretherapeutic staging did not reach significance at p>0.05 by Fisher's t-test. Hybrid-PET obtained a sensitivity of 93%, a specifity of 79%, a positive of 82% and a negative predictive value of 92% for detection of residual disease. The values for CT+US were 87%, 64%, 72% and 88% respectively. Conclusion: FDG Hybrid-PET is as or even more accurate than standard morphologic diagnostic methods for prestaging in malignant lymphoma. Additionally, there is a substancial benefit for therapy monitoring of residual disease using coincidence detection PET with a 3/4-inch crystal gamma camera. (orig.) [German] Ziel der vorliegenden retrospektiven Studie war die Validierung der klinischen Wertigkeit von F-18-FDG-PET mittels Doppelkopf-Koinzidenz-Gammakamera bei Lymphompatienten. Die Ergebnisse von prae- und post-therapeutischem Staging wurden mit dem konservativ bildgebender Verfahren verglichen. Methoden: 48 Patienten (28 NHL, 20 Morbus Hodgkin) erhielten FDG-DK-PET-Untersuchungen. Ein praetherapeutisches Staging wurde bei 28 Patienten durchgefuehrt, 9 von diesen hatten weitere Kontrollstudien nach abgeschlossenem

  5. Development of a small prototype for a proof-of-concept of OpenPET imaging

    International Nuclear Information System (INIS)

    Yamaya, Taiga; Yoshida, Eiji; Wakizaka, Hidekatsu; Kokuryo, Daisuke; Tsuji, Atsushi; Mitsuhashi, Takayuki; Tashima, Hideaki; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo; Kinouchi, Shoko; Inaniwa, Taku; Sato, Shinji; Nakajima, Yasunori; Kawai, Hideyuki; Haneishi, Hideaki; Suga, Mikio

    2011-01-01

    The OpenPET geometry is our new idea to visualize a physically opened space between two detector rings. In this paper, we developed the first small prototype to show a proof-of-concept of OpenPET imaging. Two detector rings of 110 mm diameter and 42 mm axial length were placed with a gap of 42 mm. The basic imaging performance was confirmed through phantom studies; the open imaging was realized at the cost of slight loss of axial resolution and 24% loss of sensitivity. For a proof-of-concept of PET image-guided radiation therapy, we carried out the in-beam tests with 11 C radioactive beam irradiation in the heavy ion medical accelerator in Chiba to visualize in situ distribution of primary particles stopped in a phantom. We showed that PET images corresponding to dose distribution were obtained. For an initial proof-of-concept of real-time multimodal imaging, we measured a tumor-inoculated mouse with 18 F-FDG, and an optical image of the mouse body surface was taken during the PET measurement by inserting a digital camera in the ring gap. We confirmed that the tumor in the gap was clearly visualized. The result also showed the extension effect of an axial field-of-view (FOV); a large axial FOV of 126 mm was obtained with the detectors that originally covered only an 84 mm axial FOV. In conclusion, our initial imaging studies showed promising performance of the OpenPET.

  6. Development of a small prototype for a proof-of-concept of OpenPET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yamaya, Taiga; Yoshida, Eiji; Wakizaka, Hidekatsu; Kokuryo, Daisuke; Tsuji, Atsushi; Mitsuhashi, Takayuki; Tashima, Hideaki; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo; Kinouchi, Shoko [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Inaniwa, Taku; Sato, Shinji [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Nakajima, Yasunori [Interdisciplinary Graduate School of Science and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama, Kanagawa 226-8503 (Japan); Kawai, Hideyuki; Haneishi, Hideaki; Suga, Mikio, E-mail: taiga@nirs.go.jp [Chiba University, 1-33 Yayoicho, Inage-ku, Chiba 263-8522 (Japan)

    2011-02-21

    The OpenPET geometry is our new idea to visualize a physically opened space between two detector rings. In this paper, we developed the first small prototype to show a proof-of-concept of OpenPET imaging. Two detector rings of 110 mm diameter and 42 mm axial length were placed with a gap of 42 mm. The basic imaging performance was confirmed through phantom studies; the open imaging was realized at the cost of slight loss of axial resolution and 24% loss of sensitivity. For a proof-of-concept of PET image-guided radiation therapy, we carried out the in-beam tests with {sup 11}C radioactive beam irradiation in the heavy ion medical accelerator in Chiba to visualize in situ distribution of primary particles stopped in a phantom. We showed that PET images corresponding to dose distribution were obtained. For an initial proof-of-concept of real-time multimodal imaging, we measured a tumor-inoculated mouse with {sup 18}F-FDG, and an optical image of the mouse body surface was taken during the PET measurement by inserting a digital camera in the ring gap. We confirmed that the tumor in the gap was clearly visualized. The result also showed the extension effect of an axial field-of-view (FOV); a large axial FOV of 126 mm was obtained with the detectors that originally covered only an 84 mm axial FOV. In conclusion, our initial imaging studies showed promising performance of the OpenPET.

  7. Integrated PET/MRI for whole-body staging of patients with primary cervical cancer: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Grueneisen, Johannes; Kinner, Sonja; Forsting, Michael; Lauenstein, Thomas; Umutlu, Lale [University Hospital Essen, University of Duisburg-Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Schaarschmidt, Benedikt Michael [University Hospital Dusseldorf, University of Dusseldorf, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Heubner, Martin; Aktas, Bahriye [University Hospital Essen, University of Duisburg-Essen, Department of Obstetrics and Gynecology, Essen (Germany); Ruhlmann, Verena [University Hospital Essen, University of Duisburg-Essen, Department of Nuclear Medicine, Essen (Germany)

    2015-11-15

    To assess the diagnostic value of integrated PET/MRI for whole-body staging of cervical cancer patients, as well as to investigate a potential association between PET/MRI derived functional parameters and prognostic factors of cervical cancer. The present study was approved by the local institutional review board. Twenty-seven patients with histopathologically confirmed cervical cancer were prospectively enrolled in our study. All patients underwent a whole-body PET/MRI examination after written informed consent was obtained. Two radiologists separately evaluated the PET/MRI data sets regarding the determination of local tumor extent of primary cervical cancer lesions, as well as detection of nodal and distant metastases. Furthermore, SUV and ADC values of primary tumor lesions were analyzed and correlated with dedicated prognostic factors of cervical cancer. Results based on histopathology and cross-sectional imaging follow-up served as the reference standard. PET/MRI enabled the detection of all 27 primary tumor lesions of the uterine cervix and allowed for the correct determination of the T-stage in 23 (85 %) out of the 27 patients. Furthermore, the calculated sensitivity, specificity and diagnostic accuracy for the detection of nodal positive patients (n = 11) were 91 %, 94 % and 93 %, respectively. PET/MRI correctly identified regional metastatic disease (N1-stage) in 8/10 (80 %) patients and non-regional lymph node metastases in 5/5 (100 %) patients. In addition, quantitative analysis of PET and MRI derived functional parameters (SUV; ADC values) revealed a significant correlation with pathological grade and tumor size (p < 0.05). The present study demonstrates the high potential of integrated PET/MRI for the assessment of primary tumor and the detection of lymph node metastases in patients with cervical cancer. Providing additional prognostic information, PET/MRI may serve as a valuable diagnostic tool for cervical cancer patients in a pretreatment setting

  8. Integrated PET/MRI for whole-body staging of patients with primary cervical cancer: preliminary results

    International Nuclear Information System (INIS)

    Grueneisen, Johannes; Kinner, Sonja; Forsting, Michael; Lauenstein, Thomas; Umutlu, Lale; Schaarschmidt, Benedikt Michael; Heubner, Martin; Aktas, Bahriye; Ruhlmann, Verena

    2015-01-01

    To assess the diagnostic value of integrated PET/MRI for whole-body staging of cervical cancer patients, as well as to investigate a potential association between PET/MRI derived functional parameters and prognostic factors of cervical cancer. The present study was approved by the local institutional review board. Twenty-seven patients with histopathologically confirmed cervical cancer were prospectively enrolled in our study. All patients underwent a whole-body PET/MRI examination after written informed consent was obtained. Two radiologists separately evaluated the PET/MRI data sets regarding the determination of local tumor extent of primary cervical cancer lesions, as well as detection of nodal and distant metastases. Furthermore, SUV and ADC values of primary tumor lesions were analyzed and correlated with dedicated prognostic factors of cervical cancer. Results based on histopathology and cross-sectional imaging follow-up served as the reference standard. PET/MRI enabled the detection of all 27 primary tumor lesions of the uterine cervix and allowed for the correct determination of the T-stage in 23 (85 %) out of the 27 patients. Furthermore, the calculated sensitivity, specificity and diagnostic accuracy for the detection of nodal positive patients (n = 11) were 91 %, 94 % and 93 %, respectively. PET/MRI correctly identified regional metastatic disease (N1-stage) in 8/10 (80 %) patients and non-regional lymph node metastases in 5/5 (100 %) patients. In addition, quantitative analysis of PET and MRI derived functional parameters (SUV; ADC values) revealed a significant correlation with pathological grade and tumor size (p < 0.05). The present study demonstrates the high potential of integrated PET/MRI for the assessment of primary tumor and the detection of lymph node metastases in patients with cervical cancer. Providing additional prognostic information, PET/MRI may serve as a valuable diagnostic tool for cervical cancer patients in a pretreatment setting

  9. Simulation studies for the in-vivo dose verification of particle therapy

    International Nuclear Information System (INIS)

    Rohling, Heide

    2015-01-01

    An increasing number of cancer patients is treated with proton beams or other light ion beams which allow to deliver dose precisely to the tumor. However, the depth dose distribution of these particles, which enables this precision, is sensitive to deviations from the treatment plan, as e.g. anatomical changes. Thus, to assure the quality of the treatment, a non-invasive in-vivo dose verification is highly desired. This monitoring of particle therapy relies on the detection of secondary radiation which is produced by interactions between the beam particles and the nuclei of the patient's tissue. Up to now, the only clinically applied method for in-vivo dosimetry is Positron Emission Tomography which makes use of the β + -activity produced during the irradiation (PT-PET). Since from a PT-PET measurement the applied dose cannot be directly deduced, the simulated distribution of β + -emitting nuclei is used as a basis for the analysis of the measured PT-PET data. Therefore, the reliable modeling of the production rates and the spatial distribution of the β + -emitters is required. PT-PET applied during instead of after the treatment is referred to as in-beam PET. A challenge concerning in-beam PET is the design of the PET camera, because a standard full-ring scanner is not feasible. Thus, for in-beam PET and PGI dedicated detection systems and, moreover, profound knowledge about the corresponding radiation fields are required. Using various simulation codes, this thesis contributes to the modelling of the β + -emitters and photons produced during particle irradiation, as well as to the evaluation and optimization of hardware for both techniques. Concerning the modeling of the production of the relevant β + -emitters, the abilities of the Monte Carlo simulation code PHITS and of the deterministic, one-dimensional code HIBRAC were assessed. HIBRAC was substantially extended to enable the modeling of the depth-dependent yields of specific nuclides. For proton

  10. Detection of Cancer with PET and PET/CT in Asymptomatic Volunteers

    International Nuclear Information System (INIS)

    Chung, Ji In; Choi, Joon Young; Lee, Kyung Han; Kim, Byung Tae; Choi, Yoon Ho; Cho, Han Byoul; Shim, Jae Yong

    2009-01-01

    We retrospectively investigated the diagnostic performance of 18 F-fluorodeoxyglucose positron emission tomography (PET) and PET/CT for cancer detection in asymptomatic health-check examinees. This study consisted of 5091 PET or PET/CT conducted as part of annual health examination at one hospital from March 1998 to February 2008. To find the incidence of cancers, medical records of the subjects were thoroughly reviewed for a follow-up period of one year. The patterns of formal readings of PET and PET/CT were analyzed to assess the sensitivity and specificity for cancer detection. The histopathology and stage of the cancers were evaluated in relation to the results of PET. Eighty-six cancers (1.7%) were diagnosed within one year after PET or PET/CT. When PET and PET/CT results were combined, the sensitivity was 48.8% and specificity was 81.1% for cancer detection. PET only had a sensitivity of 46.2% and a specificity of 81.4%, and PET/CT only had a sensitivity of 75.0% and a specificity of 78.5% respectively. There were no significant differences in cancer site, stage and histopathology between PET positive and PET negative cancers. In 19.3% of formal readings of PET and PET/CT, further evaluation to exclude malignancy or significant disease was recommended. Head and neck area and upper gastrointestinal tract were commonly recommended sites for further evaluation. PET and PET/CT showed moderate performance for detecting cancers in asymptomatic adults in this study. More experience and further investigation are needed to overcome limitations of PET and PET/CT for cancer screening

  11. Dual cameras acquisition and display system of retina-like sensor camera and rectangular sensor camera

    Science.gov (United States)

    Cao, Nan; Cao, Fengmei; Lin, Yabin; Bai, Tingzhu; Song, Shengyu

    2015-04-01

    For a new kind of retina-like senor camera and a traditional rectangular sensor camera, dual cameras acquisition and display system need to be built. We introduce the principle and the development of retina-like senor. Image coordinates transformation and interpolation based on sub-pixel interpolation need to be realized for our retina-like sensor's special pixels distribution. The hardware platform is composed of retina-like senor camera, rectangular sensor camera, image grabber and PC. Combined the MIL and OpenCV library, the software program is composed in VC++ on VS 2010. Experience results show that the system can realizes two cameras' acquisition and display.

  12. FDG-PET imaging of lower extremity muscular activity during level walking

    International Nuclear Information System (INIS)

    Oi, Naoyuki; Iwaya, Tsutomu; Tobimatsu, Yoshiko; Fujimoto, Toshihiko; Itoh, Masatoshi; Yamaguchi, Keiichiro

    2003-01-01

    We analyzed muscular activity of the lower extremities during level walking using positron emission tomography (PET) with 18 F-fluorodeoxyglucose ( 18 F-FDG). We examined 17 healthy male subjects; 11 were assigned to a walking group and 6 to a resting group. After 18 F-FDG injection, the walking group subjects walked at a free speed for 15 min. A whole-body image was then obtained by a PET camera, and the standardized uptake ratio (SUR) was computed for each muscle. The SUR for each muscle of the walking group was compared with that for the corresponding muscles in the resting group. The level of muscular activity of all the muscles we examined were higher during level walking than when resting. The activity of the lower leg muscles was higher than that of the thigh muscles during level walking. The muscular activity of the soleus was highest among all the muscles examined. Among the gluteal muscles, the muscular activity of the gluteus minimus was higher than that of the gluteus maximus and gluteus medius. The concurrent validity of measuring muscular activity of the lower extremity during level walking by the PET method using 18 F-FDG was demonstrated. (author)

  13. PET

    DEFF Research Database (Denmark)

    Mariager, Rasmus Mølgaard; Schmidt, Regin; Heiberg, Morten Rievers

    PET handler om den hemmelige tjenestes arbejde under den kolde krig 1945-1989. Her fortæller Regin Schmidt, Rasmus Mariager og Morten Heiberg om de mest dramatiske og interessante sager fra PET's arkiv. PET er på flere måder en udemokratisk institution, der er sat til at vogte over demokratiet....... Dens virksomhed er skjult for offentligheden, den overvåger borgernes aktiviteter, og den registrerer følsomme personoplysninger. Historien om PET rejser spørgsmålet om, hvad man skal gøre, når befolkningen i et demokrati er kritisk indstillet over for overvågningen af lovlige politiske aktiviteter......, mens myndighederne mener, at det er nødvendigt for at beskytte demokratiet. PET er på en gang en fortælling om konkrete aktioner og begivenheder i PET's arbejde og et stykke Danmarkshistorie. Det handler om overvågning, spioner, politisk ekstremisme og international terrorisme.  ...

  14. Clinical usefulness of PET in the management of oral cancer. Comparison between FDG-PET and MET-PET

    International Nuclear Information System (INIS)

    Kitagawa, Yoshimasa; Saitoh, Masaaki; Nakamura, Mikiko

    2007-01-01

    Inductive chemoradiotherapy has played an important role in preserving organs and functions in patients with oral squamous cell carcinoma (SCC). To determine whether a reduced form of surgery should be performed after chemoradiotherapy, accurate evaluation of residual tumor cells is essential. We investigated the clinical value of positron emission tomography with 18 F labeled fluorodeoxyglucose (FDG-PET) in the management of oral SCCs. Forty-five patients underwent two FDG-PET studies, one prior to and one at 6 weeks after the chemoradiotherapy. Pretreatment FDG-PET was useful in predicting the response to treatment. Posttreatment FDG-PET could evaluate residual viable cells and prognosis. Organ preservation may be feasible based on PET evaluation. Hence FDG-PET is a valuable tool in the treatment of oral cancer. 11 C-Methionine (MET) is another promising tracer for PET that can be used to assess metabolic demand for amino acids in cancer cells. A MET-PET and FDG-PET study was performed during the same period to investigate diagnostic accuracy in 40 oral malignancies. Sensitivity and positive predictive value of MET-PET were 95% and 100%, respectively, and were comparable with those of FDG-PET. Further study is required to determine the diagnostic significance of MET-PET in evaluating response to chemoradiotherapy. (author)

  15. Observations of the Perseids 2012 using SPOSH cameras

    Science.gov (United States)

    Margonis, A.; Flohrer, J.; Christou, A.; Elgner, S.; Oberst, J.

    2012-09-01

    The Perseids are one of the most prominent annual meteor showers occurring every summer when the stream of dust particles, originating from Halley-type comet 109P/Swift-Tuttle, intersects the orbital path of the Earth. The dense core of this stream passes Earth's orbit on the 12th of August producing the maximum number of meteors. The Technical University of Berlin (TUB) and the German Aerospace Center (DLR) organize observing campaigns every summer monitoring the Perseids activity. The observations are carried out using the Smart Panoramic Optical Sensor Head (SPOSH) camera system [0]. The SPOSH camera has been developed by DLR and Jena-Optronik GmbH under an ESA/ESTEC contract and it is designed to image faint, short-lived phenomena on dark planetary hemispheres. The camera features a highly sensitive backilluminated 1024x1024 CCD chip and a high dynamic range of 14 bits. The custom-made fish-eye lens offers a 120°x120° field-of-view (168° over the diagonal). Figure 1: A meteor captured by the SPOSH cameras simultaneously during the last 2011 observing campaign in Greece. The horizon including surrounding mountains can be seen in the image corners as a result of the large FOV of the camera. The observations will be made on the Greek Peloponnese peninsula monitoring the post-peak activity of the Perseids during a one-week period around the August New Moon (14th to 21st). Two SPOSH cameras will be deployed in two remote sites in high altitudes for the triangulation of meteor trajectories captured at both stations simultaneously. The observations during this time interval will give us the possibility to study the poorly-observed postmaximum branch of the Perseid stream and compare the results with datasets from previous campaigns which covered different periods of this long-lived meteor shower. The acquired data will be processed using dedicated software for meteor data reduction developed at TUB and DLR. Assuming a successful campaign, statistics, trajectories

  16. Temporal lobe dysfunction in childhood autism: a PET study; Dysfonctionnement bitemporal dans l'autisme infantile: etude en tomographie par emission de positons

    Energy Technology Data Exchange (ETDEWEB)

    Boddaert, N.; Poline, J.B.; Brunelle, F.; Zilbovicius, M. [Service Hospitalier Frederic Joliot, ER-M INSERM 0205, DSV, DRM CEA, 91 - Orsay (France); Brunelle, F. [Centre Hospitalier Universitaire Necker-Enfants-Malades, Service de Radiologie Pediatrique, 75 - Paris (France); Chabane, N. [Hopital Robert-Debre, Service de Pedopsychiatrie, 75 - Paris (France); Barthelemy, C.; Zilbovicius, M. [Centre Hospitalier Universitaire Bretonneau, INSERM Unite 316, 37 - Tours (France); Bourgeois, M. [Centre Hospitalier Universitaire Necker-Enfants-Malades, Dept. de Pediatrie, 75 - Paris (France); Samson, Y. [Centre Hospitalier Universitaire Pitie-Salpetriere, Service des Urgences Cerebraux Vasculaires, 75 - Paris (France)

    2002-12-01

    Childhood autism is a severe developmental disorder that impairs the acquisition of some of the most important skills in human life. Progress in understanding the neural basis of childhood autism requires clear and reliable data indicating specific neuro-anatomical or neuro-physiological abnormalities. The purpose of the present study was to research localized brain dysfunction in autistic children using functional brain imaging. Regional cerebral blood flow (rCBF) was measured with positron emission tomography (PET) in 21 primary autistic children and 10 age-matched non autistic children. A statistical parametric analysis of rCBF images revealed significant bilateral temporal hypoperfusion in the associative auditory cortex (superior temporal gyrus) and in the multimodal cortex (superior temporal sulcus) in the autistic group (p<0.001). In addition, temporal hypoperfusion was detected individually in 77% of autistic children. These findings provide robust evidence of well localized functional abnormalities in autistic children located in the superior temporal lobe. Such localized abnormalities were not detected with the low resolution PET camera (14-22). This study suggests that high resolution PET camera combined with statistical parametric mapping is useful to understand developmental disorders. (authors)

  17. The Kinetics and Reproducibility of 18F-Sodium Fluoride for Oncology Using Current PET Camera Technology

    Science.gov (United States)

    Kurdziel, Karen A.; Shih, Joanna H.; Apolo, Andrea B.; Lindenberg, Liza; Mena, Esther; McKinney, Yolanda; Adler, Stephen S.; Turkbey, Baris; Dahut, William; Gulley, James L.; Madan, Ravi A.; Landgren, Ola; Choyke, Peter L.

    2012-01-01

    We evaluated the kinetics of 18F-sodium fluoride (NaF) and reassessed the recommended dose, optimal uptake period, and reproducibility using a current-generation PET/CT scanner. Methods In this prospective study, 73 patients (31 patients with multiple myeloma or myeloma precursor disease and 42 with prostate cancer) were injected with a mean administered dose of 141 MBq of 18F-NaF. Sixty patients underwent 3 sequential sessions of 3-dimensional PET/CT of the torso beginning ~15 min after 18F-NaF injection, followed by a whole-body 3-dimensional PET/CT at 2 h. The remaining 13 prostate cancer patients were imaged only at 2 and 3 h after injection. Twenty-one prostate cancer patients underwent repeat baseline studies (mean interval, 5.9 d) to evaluate reproducibility. Results The measured effective dose was 0.017 mSv/MBq, with the urinary bladder, osteogenic cells, and red marrow receiving the highest doses at 0.080, 0.077, and 0.028 mGy/MBq, respectively. Visual analysis showed that uptake in both normal and abnormal bone increased with time; however, the rate of increase decreased with time. A semiautomated workflow provided objective uptake parameters, including the mean standardized uptake value of all pixels within bone with SUVs greater than 10 and the average of the mean SUV of all malignant lesions identified by the algorithm. The values of these parameters for the images beginning at ~15 min and ~35 min were significantly different (0.3% change/minute). Differences between the later imaging time points were not significant (P 0.9) and relatively low critical percent change (the value above which a change can be considered real) for these parameters. The tumor-to-normal bone ratio, based on the SUVmax of identified malignant lesions, decreased with time; however, this difference was small, estimated at ~0.16%/min in the first hour. Conclusion 18F-NaF PET/CT images obtained with modest radiation exposures can result in highly reproducible imaging parameters

  18. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain

    International Nuclear Information System (INIS)

    Jung, Jin Ho; Choi, Yong; Jung, Jiwoong; Kim, Sangsu; Lim, Hyun Keong; Im, Ki Chun; Oh, Chang Hyun; Park, Hyun-wook; Kim, Kyung Min; Kim, Jong Guk

    2015-01-01

    Purpose: The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. Methods: The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. The PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. Results: No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was

  19. Development of PET/MRI with insertable PET for simultaneous PET and MR imaging of human brain

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jin Ho; Choi, Yong, E-mail: ychoi.image@gmail.com; Jung, Jiwoong; Kim, Sangsu; Lim, Hyun Keong; Im, Ki Chun [Department of Electronic Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul 121-742 (Korea, Republic of); Oh, Chang Hyun; Park, Hyun-wook [Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 305-701 (Korea, Republic of); Kim, Kyung Min; Kim, Jong Guk [Korea Institute of Radiological and Medical Science, 75 Nowon-ro, Nowon-gu, Seoul 139-709 (Korea, Republic of)

    2015-05-15

    Purpose: The purpose of this study was to develop a dual-modality positron emission tomography (PET)/magnetic resonance imaging (MRI) with insertable PET for simultaneous PET and MR imaging of the human brain. Methods: The PET detector block was composed of a 4 × 4 matrix of detector modules, each consisting of a 4 × 4 array LYSO coupled to a 4 × 4 Geiger-mode avalanche photodiode (GAPD) array. The PET insert consisted of 18 detector blocks, circularly mounted on a custom-made plastic base to form a ring with an inner diameter of 390 mm and axial length of 60 mm. The PET gantry was shielded with gold-plated conductive fabric tapes with a thickness of 0.1 mm. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuit. The flat cables were shielded with a mesh-type aluminum sheet with a thickness of 0.24 mm. The position decoder circuit and field programmable gate array-embedded DAQ modules were enclosed in an aluminum box with a thickness of 10 mm and located at the rear of the MR bore inside the MRI room. A 3-T human MRI system with a Larmor frequency of 123.7 MHz and inner bore diameter of 60 cm was used as the PET/MRI hybrid system. A custom-made radio frequency (RF) coil with an inner diameter of 25 cm was fabricated. The PET was positioned between gradient and the RF coils. PET performance was measured outside and inside the MRI scanner using echo planar imaging, spin echo, turbo spin echo, and gradient echo sequences. MRI performance was also evaluated with and without the PET insert. The stability of the newly developed PET insert was evaluated and simultaneous PET and MR images of a brain phantom were acquired. Results: No significant degradation of the PET performance caused by MR was observed when the PET was operated using various MR imaging sequences. The signal-to-noise ratio of MR images was slightly degraded due to the PET insert installed inside the MR bore while the homogeneity was

  20. Evaluation of attenuation correction in cardiac PET using PET/MR.

    Science.gov (United States)

    Lau, Jeffrey M C; Laforest, R; Sotoudeh, H; Nie, X; Sharma, S; McConathy, J; Novak, E; Priatna, A; Gropler, R J; Woodard, P K

    2017-06-01

    Simultaneous acquisition Positron emission tomography/magnetic resonance (PET/MR) is a new technology that has potential as a tool both in research and clinical diagnosis. However, cardiac PET acquisition has not yet been validated using MR imaging for attenuation correction (AC). The goal of this study is to evaluate the feasibility of PET imaging using a standard 2-point Dixon volume interpolated breathhold examination (VIBE) MR sequence for AC. Evaluation was performed in both phantom and patient data. A chest phantom containing heart, lungs, and a lesion insert was scanned by both PET/MR and PET/CT. In addition, 30 patients underwent whole-body 18 F-fluorodeoxyglucose PET/CT followed by simultaneous cardiac PET/MR. Phantom study showed 3% reduction of activity values in the myocardium due to the non-inclusion of the phased array coil in the AC. In patient scans, average standardized uptake values (SUVs) obtained by PET/CT and PET/MR showed no significant difference (n = 30, 4.6 ± 3.5 vs 4.7 ± 2.8, P = 0.47). There was excellent per patient correlation between the values acquired by PET/CT and PET/MR (R 2  = 0.97). Myocardial SUVs PET imaging using MR for AC shows excellent correlation with myocardial SUVs obtained by standard PET/CT imaging. The 2-point Dixon VIBE MR technique can be used for AC in simultaneous PET/MR data acquisition.

  1. Single photon detection and localization accuracy with an ebCMOS camera

    Energy Technology Data Exchange (ETDEWEB)

    Cajgfinger, T. [CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, Villeurbanne F-69622 (France); Dominjon, A., E-mail: agnes.dominjon@nao.ac.jp [Université de Lyon, Université de Lyon 1, Lyon 69003 France. (France); Barbier, R. [CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, Villeurbanne F-69622 (France); Université de Lyon, Université de Lyon 1, Lyon 69003 France. (France)

    2015-07-01

    The CMOS sensor technologies evolve very fast and offer today very promising solutions to existing issues facing by imaging camera systems. CMOS sensors are very attractive for fast and sensitive imaging thanks to their low pixel noise (1e-) and their possibility of backside illumination. The ebCMOS group of IPNL has produced a camera system dedicated to Low Light Level detection and based on a 640 kPixels ebCMOS with its acquisition system. After reminding the principle of detection of an ebCMOS and the characteristics of our prototype, we confront our camera to other imaging systems. We compare the identification efficiency and the localization accuracy of a point source by four different photo-detection devices: the scientific CMOS (sCMOS), the Charge Coupled Device (CDD), the Electron Multiplying CCD (emCCD) and the Electron Bombarded CMOS (ebCMOS). Our ebCMOS camera is able to identify a single photon source in less than 10 ms with a localization accuracy better than 1 µm. We report as well efficiency measurement and the false positive identification of the ebCMOS camera by identifying more than hundreds of single photon sources in parallel. About 700 spots are identified with a detection efficiency higher than 90% and a false positive percentage lower than 5. With these measurements, we show that our target tracking algorithm can be implemented in real time at 500 frames per second under a photon flux of the order of 8000 photons per frame. These results demonstrate that the ebCMOS camera concept with its single photon detection and target tracking algorithm is one of the best devices for low light and fast applications such as bioluminescence imaging, quantum dots tracking or adaptive optics.

  2. 18F FDG PET/CT in differential diagnosis of Parkinsonian disorders

    International Nuclear Information System (INIS)

    Deepa; Moon, S.; Mahajan, S.; Thapa, P.; Gupta, P.; Sahana; Tripathi, M.; Sharma, R.; Mondal, A.; Batla, A.; Nehru, R.; Kushwaha, S.; Mishra, A.K.

    2010-01-01

    Full text: Differential diagnosis of Parkinsonian disorders can be challenging in the early phase of disease course. Positron Emission Tomography (PET) imaging with 18 F Fluorodeoxyglucose (FDG) has been used to identify characteristic patterns of glucose metabolism in patients with idiopathic Parkinson's Disease (PD) as well as variant forms of Parkinsonism such as Multisystem Atrophy (MSA), Progressive Supranuclear Palsy (PSP) and cortico basal ganglionic degeneration (CBGD). In this study we assessed the utility of 18 F FDG PET/CT in the differential diagnosis Parkinsonian syndromes. 66 Parkinsonian patients with a mean age of 59.6 ± 11.50 years, male: female ratio of 3.12:1, age range of 35-84 years with a disease duration of 2.6 ± .68 years were referred for FDG PET to determine whether their scan patterns could distinguish idiopathic Parkinsons from the Parkinson plus syndromes. Approximately 60 minutes following intravenous injection of 370 MBq of 18 F-FDG, PET/CT scan of the brain was acquired in a whole-body Full Ring PET/CT scanner (Discovery STE16 camera). A low dose CT was obtained on the same area without IV contrast for attenuation correction and coregistration. Images were reconstructed using a 3D VUE algorithm and slices were reformatted into transaxial, coronal and sagittal views. Subsequently the images were processed and visually analyzed on Xeleris workstation. Images were classified by visual analysis into the various subgroups, those with normal to increased basal ganglia uptake were classified into Idiopathic Parkinson's (40/45) and when basal ganglia uptake was decreased they were Parkinsons Plus (19/21). The study demonstrates that 18 F FDG PET performed at the time of initial referral for parkinsonism could accurately classify patients into Parkinson's disease and Parkinson plus subtypes

  3. Evaluating the purity of a (57)Co flood source by PET.

    Science.gov (United States)

    DiFilippo, Frank P

    2014-11-01

    Flood sources of (57)Co are commonly used for quality control of gamma cameras. Flood uniformity may be affected by the contaminants (56)Co and (58)Co, which emit higher energy photons. Although vendors specify a maximum combined (56)Co and (58)Co activity, a convenient test for flood source purity that is feasible in a clinical environment would be desirable. Both (56)Co and (58)Co emit positrons with branching 19.6% and 14.9%, respectively. As is known from (90)Y imaging, a positron emission tomography (PET) scanner is capable of quantitatively imaging very weak positron emission in a high single-photon background. To evaluate this approach, two (57)Co flood sources were scanned with a clinical PET/CT multiple times over a period of months. The (56)Co and (58)Co activity was clearly visible in the reconstructed PET images. Total impurity activity was quantified from the PET images after background subtraction of prompt gamma coincidences. Time-of-flight PET reconstruction was highly beneficial for accurate image quantification. Repeated measurements of the positron-emitting impurities showed excellent agreement with an exponential decay model. For both flood sources studied, the fit parameters indicated a zero intercept and a decay half-life consistent with a mixture of (56)Co and (58)Co. The total impurity activity at the reference date was estimated to be 0.06% and 0.07% for the two sources, which was consistent with the vendor's specification of <0.12%. The robustness of the repeated measurements and a thorough analysis of the detector corrections and physics suggest that the accuracy is acceptable and that the technique is feasible. Further work is needed to validate the accuracy of this technique with a calibrated high resolution gamma spectrometer as a gold standard, which was not available for this study, and for other PET detector models.

  4. MRI fused with prone FDG PET/CT improves the primary tumour staging of patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Velloso, Maria J.; Ribelles, Maria J.; Rodriguez, Macarena; Sancho, Lidia; Prieto, Elena [Clinica Universidad de Navarra, Department of Nuclear Medicine, Pamplona (Spain); Fernandez-Montero, Alejandro [Clinica Universidad de Navarra, Department of Occupational Medicine, Pamplona (Spain); Santisteban, Marta [Clinica Universidad de Navarra, Department of Oncology, Pamplona (Spain); Rodriguez-Spiteri, Natalia; Martinez-Regueira, Fernando [Clinica Universidad de Navarra, Department of Surgery, Pamplona (Spain); Idoate, Miguel A. [Clinica Universidad de Navarra, Department of Pathology, Pamplona (Spain); Elizalde, Arlette; Pina, Luis J. [Clinica Universidad de Navarra, Department of Radiology, Pamplona (Spain)

    2017-08-15

    Our aim was to evaluate the diagnostic accuracy of magnetic resonance imaging (MRI) fused with prone 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) in primary tumour staging of patients with breast cancer. This retrospective study evaluated 45 women with 49 pathologically proven breast carcinomas. MRI and prone PET-CT scans with time-of-flight and point-spread-function reconstruction were performed with the same dedicated breast coil. The studies were assessed by a radiologist and a nuclear medicine physician, and evaluation of fused images was made by consensus. The final diagnosis was based on pathology (90 lesions) or follow-up ≥ 24 months (17 lesions). The study assessed 72 malignant and 35 benign lesions with a median size of 1.8 cm (range 0.3-8.4 cm): 31 focal, nine multifocal and nine multicentric cases. In lesion-by-lesion analysis, sensitivity, specificity, positive and negative predictive values were 97%, 80%, 91% and 93% for MRI, 96%, 71%, 87%, and 89% for prone PET, and 97%. 94%, 97% and 94% for MRI fused with PET. Areas under the curve (AUC) were 0.953, 0.850, and 0.983, respectively (p < 0.01). MRI fused with FDG-PET is more accurate than FDG-PET in primary tumour staging of breast cancer patients and increases the specificity of MRI. (orig.)

  5. Basic concepts on positron emission tomography in oncology and pediatric peculiarities

    International Nuclear Information System (INIS)

    Giammarile, F.; Pellet, O.

    2002-01-01

    (Positron Emission Tomography (PET) is an old functional imaging method, pertaining to the nuclear medicine field, based on the utilisation of positrons emitting nuclei, fixed on targeted molecules. Available since the Seventies, the clinical impact of PET grows daily, particularly in oncology. This method rests on the coincidence detection of the photons issued by the annihilation of the positron. It can be carried out on dedicated scans, equipped with a crown of detectors (PET camera) or on classical cameras whose crystal and electronic system has been adapted CDET camera). The 2-deoxy-2 fluoro-D-glucose marked with fluorine 18 [18FDG or FDG is a glucose analogue. Its cellular uptake uses the facilitated transport of glucose but its metabolism is partial because, contrary to this one, it remains within the cell. This allows functional studies (evaluation of glucose metabolism) on the cell. FDG uptake is thus increased under the pathological conditions comprising an increase in the consumption of glucose either by increase in glycolysis (malignant tumoral tissue) or by increase in the only anaerobic cycle (ischaemia). Consequently, this diagnostic method identifies in vivo the hyper-metabolism of malignant cells and provides a quantification of the tumoral glycolysis, during and after treatment. In Paediatrics, its diffusion and its use in clinical routine, are currently limited, because of the limited availability of the equipment. It is probable that with the awaited rise of PET in France, the paediatric applications will also see their place increasing in the diagnostic strategy of cancer. (authors)

  6. 4D offline PET-based treatment verification in ion beam therapy. Experimental and clinical evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kurz, Christopher

    2014-06-12

    consideration, particularly for patients exhibiting motion amplitudes of above 1cm and a sufficiently large number of detected true coincidences during their post-irradiation PET scan. Despite the application of an optimised PET image reconstruction scheme, as retrieved from a dedicated phantom imaging study in the scope of this work, the small number of counts and the resulting high level of image noise were identified as a major limiting factor for the detection of motion-induced dose inhomogeneities within the patient. Moreover, the biological washout modelling of the irradiation-induced isotopes proved to be not sufficiently accurate and thereby impede a quantitative analysis of measured and simulated data under consideration of target motion. In future, improvements are particularly foreseen through dedicated noise-robust time-resolved (4D) image reconstruction algorithms, an improved tracking of the organ motion, e.g., by ultrasound (US) imaging, as implemented for the first time in 4D PET imaging in the scope of this work, as well as by patient-specific washout models.

  7. 4D offline PET-based treatment verification in ion beam therapy. Experimental and clinical evaluation

    International Nuclear Information System (INIS)

    Kurz, Christopher

    2014-01-01

    consideration, particularly for patients exhibiting motion amplitudes of above 1cm and a sufficiently large number of detected true coincidences during their post-irradiation PET scan. Despite the application of an optimised PET image reconstruction scheme, as retrieved from a dedicated phantom imaging study in the scope of this work, the small number of counts and the resulting high level of image noise were identified as a major limiting factor for the detection of motion-induced dose inhomogeneities within the patient. Moreover, the biological washout modelling of the irradiation-induced isotopes proved to be not sufficiently accurate and thereby impede a quantitative analysis of measured and simulated data under consideration of target motion. In future, improvements are particularly foreseen through dedicated noise-robust time-resolved (4D) image reconstruction algorithms, an improved tracking of the organ motion, e.g., by ultrasound (US) imaging, as implemented for the first time in 4D PET imaging in the scope of this work, as well as by patient-specific washout models.

  8. 18F-FDG PET and PET/CT in Burkitt's lymphoma

    International Nuclear Information System (INIS)

    Karantanis, Dimitrios; Durski, Jolanta M.; Lowe, Val J.; Nathan, Mark A.; Mullan, Brian P.; Georgiou, Evangelos; Johnston, Patrick B.; Wiseman, Gregory A.

    2010-01-01

    Objective: To explore the value of 18 F fluorodeoxy-glucose (FDG) positron emission tomography (PET) in Burkitt's lymphoma. Methods: All Burkitt's lymphoma patients referred for FDG PET or FDG PET/computed tomography (CT) exams at our institution from June 2003 to June 2006 were included. Selected patients were followed and clinical information was reviewed retrospectively. Results from FDG PET-PET/CT, as blindly reviewed by a consensus of two experienced readers, were compared with the status of the disease as determined by other laboratory, clinical and imaging exams and clinical follow-up. FDG PET-PET/CT results were classified as true positive or negative and false positive or negative. The degree of FDG uptake in the positive lesions was semiquantified as maximum standard uptake value (SUVmax). Results: Fifty-seven FDG PET-PET/CT exams were done in 15 patients. Seven exams were done for initial staging, 8 during and 14 after the completion of therapy, and 28 for disease surveillance. For nodal disease FDG PET-PET/CT was true positive in 8, true negative in 47 and false positive in 2 exams (sensitivity 100%, specificity 96%). For extranodal disease FDG PET-PET/CT was true positive in 6, true negative in 48 and false positive in 3 exams (sensitivity 100%, specificity 94%). The mean SUVmax for the positive nodal lesions was 15.7 (range 6.9-21.7, median 18.5) and for extranodal lesions was 14.2 (range 6.2-24.3, median 12.4). Conclusions: FDG PET-PET/CT is sensitive for the detection of viable disease in Burkitt's lymphoma. Affected areas demonstrated high degree of uptake that was reversible upon successful implementation of treatment.

  9. Spatial resolution recovery utilizing multi-ray tracing and graphic processing unit in PET image reconstruction

    International Nuclear Information System (INIS)

    Liang, Yicheng; Peng, Hao

    2015-01-01

    Depth-of-interaction (DOI) poses a major challenge for a PET system to achieve uniform spatial resolution across the field-of-view, particularly for small animal and organ-dedicated PET systems. In this work, we implemented an analytical method to model system matrix for resolution recovery, which was then incorporated in PET image reconstruction on a graphical processing unit platform, due to its parallel processing capacity. The method utilizes the concepts of virtual DOI layers and multi-ray tracing to calculate the coincidence detection response function for a given line-of-response. The accuracy of the proposed method was validated for a small-bore PET insert to be used for simultaneous PET/MR breast imaging. In addition, the performance comparisons were studied among the following three cases: 1) no physical DOI and no resolution modeling; 2) two physical DOI layers and no resolution modeling; and 3) no physical DOI design but with a different number of virtual DOI layers. The image quality was quantitatively evaluated in terms of spatial resolution (full-width-half-maximum and position offset), contrast recovery coefficient and noise. The results indicate that the proposed method has the potential to be used as an alternative to other physical DOI designs and achieve comparable imaging performances, while reducing detector/system design cost and complexity. (paper)

  10. Contribution of co-registered PET/CT for patients with suspected recurrence of colo-rectal cancer

    International Nuclear Information System (INIS)

    Garin, E.; Devillers, A.; Prigent, F.; Girault, S.; Herry, J.Y.; Bourguet, P.; Bouriel, C.; Boudjema, K.; Campion, J.P.; Meunier, B.; Boucher, E.; Raoul, J.L.

    2003-01-01

    Positron emission tomography using 18 F fluorodeoxyglucose (PET) has proved to offer advantages for patients presenting with suspected recurrence of colo-rectal cancer. However; this examination is confronted with two disadvantages: the lack of anatomical reference marks and the presence of physiological uptake that can be difficult to locate. We carried out a retrospective study on 30 patients with suspected recurrence of Colo-rectal cancer in order to evaluate the diagnostic and therapeutic impact of PET/CT fusion images compared with PET alone. PET/CT acquisitions were performed on a prototype Positrace or on a double-detection head gamma camera in coincidence Hawkeye. PET/CT fusion images had a formal diagnostic impact for 6 patients out of 30 (20%), including 5 patients out of 12 (41%) having a suspected pelvic recurrence. In five cases, it allowed us to resolve ambiguities about whether the site of recurrence was located in the bone or the soft tissues. Furthermore, in one case we were able to locate an intra-abdominal uptake focus at the level of the liver. The PET/CT fusion images had a probable diagnostic impact for three additional patients. For two patients, the PET/CT fusion images allowed us to identify an ambiguous uptake focus as being related to physiological renal uptake. For 4 patients out of 30 (13%), the PET/CT fusion images had a clear additional therapeutic impact, including 4/12 (33%) for whom a pelvic recurrence could be suspected. The present study shows that PET/CT fusion images have an important diagnostic and therapeutic impact for patients with suspected recurrence of colorectal cancer; the impact becoming major for the subgroup of patients having a suspected pelvic recurrence. (author)

  11. PET or PET-CT with cancer screening

    International Nuclear Information System (INIS)

    Wang Taisong; Zhao Jinhua; Song Jianhua

    2007-01-01

    At present, cancer screening remains a lot of debate in contemporary medical practice. Many constitutes have done a lot of experiments in cancer screening. The same version is that recommendations and decisions regarding cancer screening should be based on reliable data, not self- approbation. Now, some institutes advocate 18 F-FDG PET or 18 F-FDG PET-CT for cancer screening, here, discussed status quo, potential financial, radiation safety and statistical data in 18 F-FDG PET or 18 F-FDG PET- CT cancer screening. (authors)

  12. PET / MRI vs. PET / CT. Indications Oncology

    International Nuclear Information System (INIS)

    Oliva González, Juan P.

    2016-01-01

    Hybrid techniques in Nuclear Medicine is currently a field in full development for diagnosis and treatment of various medical conditions. With the recent advent of PET / MRI much it speculated about whether or not it is superior to PET / CT especially in oncology. The Conference seeks to clarify this situation by dealing issues such as: State of the art technology PET / MRI; Indications Oncology; Some clinical cases. It concludes by explaining the oncological indications of both the real and current situation of the PET / MRI. (author)

  13. Application of the compress sensing theory for improvement of the TOF resolution in a novel J-PET instrument

    Directory of Open Access Journals (Sweden)

    Raczyński Lech

    2016-03-01

    Full Text Available Nowadays, in positron emission tomography (PET systems, a time of flight (TOF information is used to improve the image reconstruction process. In TOF-PET, fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten significantly a range along the line-of-response (LOR where the annihilation occurred. In the new concept, called J-PET scanner, gamma rays are detected in plastic scintillators. In a single strip of J-PET system, time values are obtained by probing signals in the amplitude domain. Owing to compressive sensing (CS theory, information about the shape and amplitude of the signals is recovered. In this paper, we demonstrate that based on the acquired signals parameters, a better signal normalization may be provided in order to improve the TOF resolution. The procedure was tested using large sample of data registered by a dedicated detection setup enabling sampling of signals with 50-ps intervals. Experimental setup provided irradiation of a chosen position in the plastic scintillator strip with annihilation gamma quanta.

  14. Application of PET and PET/CT imaging for cancer screening

    International Nuclear Information System (INIS)

    Chen Yenkung; Hu Fenglan; Shen Yehyou; Liao, A.C.; Hung, T.Z.; Su, Chentau; Chen Liangkuang

    2004-01-01

    The aim of this study was to evaluate the potential application of 18F-fluorodeoxyglucose (FDG) Positron Emission Tomography (PET) and PET/CT for cancer screening in asymptomatic individuals. Methods: The subjects consisted of 3631 physical check up examinees (1947 men, 1684 women; mean age ±SD, 52.1±8.2 y) with non-specific medical histories. Whole-body FDG PET (or PET/CT), ultrasound and tumor markers were performed on all patients. Focal hypermetabolic areas with intensities equal to or exceeding the level of FDG uptake in the brain and bladder were considered abnormal and interpreted as neoplasia. Follow-up periods were longer than one year. Results: Among the 3631 FDG PET (including 1687 PET/CT), ultrasound and tumor markers examinations, malignant tumors were discovered in 47 examinees (1.29%). PET findings were true-positive in 38 of the 47 cancers (80.9%). In addition, 32 of the 47 cancers were performed with the PET-CT scan. PET detected cancer lesions in 28 of the 32 examinees. However, the CT detected cancer lesions in only 15 of 32 examinees. Conclusion: The sensitivity of FDG PET in the detection of a wide variety of cancers is high. Most cancer can be detected with FDG PET in a resectable stage. CT of the PET/CT for localization and characteristics of the lesion shows an increased specificity of the PET scan. Using ultrasound and tumor markers may complement the PET scan in cancer screening for hepatic and urologic neoplasms. (authors)

  15. Studies on a silicon-photomultiplier-based camera for Imaging Atmospheric Cherenkov Telescopes

    Science.gov (United States)

    Arcaro, C.; Corti, D.; De Angelis, A.; Doro, M.; Manea, C.; Mariotti, M.; Rando, R.; Reichardt, I.; Tescaro, D.

    2017-12-01

    Imaging Atmospheric Cherenkov Telescopes (IACTs) represent a class of instruments which are dedicated to the ground-based observation of cosmic VHE gamma ray emission based on the detection of the Cherenkov radiation produced in the interaction of gamma rays with the Earth atmosphere. One of the key elements of such instruments is a pixelized focal-plane camera consisting of photodetectors. To date, photomultiplier tubes (PMTs) have been the common choice given their high photon detection efficiency (PDE) and fast time response. Recently, silicon photomultipliers (SiPMs) are emerging as an alternative. This rapidly evolving technology has strong potential to become superior to that based on PMTs in terms of PDE, which would further improve the sensitivity of IACTs, and see a price reduction per square millimeter of detector area. We are working to develop a SiPM-based module for the focal-plane cameras of the MAGIC telescopes to probe this technology for IACTs with large focal plane cameras of an area of few square meters. We will describe the solutions we are exploring in order to balance a competitive performance with a minimal impact on the overall MAGIC camera design using ray tracing simulations. We further present a comparative study of the overall light throughput based on Monte Carlo simulations and considering the properties of the major hardware elements of an IACT.

  16. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  17. 18FDG PET scanning of benign and malignant musculoskeletal lesions

    International Nuclear Information System (INIS)

    Feldman, Frieda; Heertum, Ronald van; Manos, Chitra

    2003-01-01

    To describe the technique, applications and advantages of 18 FDG PET scanning in detection, analysis and management of musculoskeletal lesions.Design and patients Forty-five patients (19 males,26 females) aged 9 to 81 years had radiographs, routine radionuclide scans, CT and/or MRI of clinically suspected active benign or malignant musculoskeletal lesions. 18 FDG scans with a Siemens ECAT EXACT 921 dedicated PET unit (Knoxville, Tenn.) and FWH=6 mm images acquired as a 5-6 bed examination (6 min emission and 4 min transmission) used OSEM iterative reconstruction with segmented transmission attenuation correction and a Gaussian filter (cutoff 6.7 mm). Region of interest (ROI) 3 x 3 pixel image analysis based on transverse whole body images (slice thickness 3.37 mm) generated Maximum Standard Uptake Values (Max SUV) with a cutoff of 2.0 used to distinguish benign and malignant lesions. Thirty-nine studies were available for SUV ROI analysis. Overall sensitivity for differentiating malignant from benign osseous and non-osseous lesions was 91.7% (22/24), overall specificity was 100% (11/11) with an accuracy of 91.7%. All aggressive lesions had a Max SUV >2.0. Data separating benign from malignant lesions and aggressive from benign lesions were statistically significant (P 18 FDG PET contributes unique information regarding metabolism of musculoskeletal lesions. By supplying a physiologic basis for more informed treatment and management, it influences prognosis and survival. Moreover, since residual, recurrent or metastatic tumors can be simultaneously documented on a single whole body scan, PET may theoretically prove to be cost-effective. (orig.)

  18. Authentically radiolabelled Mn(II) complexes as bimodal PET/MR tracers

    Energy Technology Data Exchange (ETDEWEB)

    Vanasschen, Christian; Brandt, Marie; Ermert, Johannes [Institute of Neuroscience and Medicine, INM-5 - Nuclear Chemistry, Forschungszentrum Jülich (Germany); Neumaier, Bernd [Institute for Radiochemistry and Experimental Molecular Imaging, Medical Clinics, University of Cologne (Germany); Coenen, Heinz H [Institute of Neuroscience and Medicine, INM-5 - Nuclear Chemistry, Forschungszentrum Jülich (Germany)

    2015-05-18

    The development of small molecule bimodal PET/MR tracers is mainly hampered by the lack of dedicated preparation methods. Authentic radiolabelling of MR contrast agents ensures easy access to such probes: a ligand, chelating a paramagnetic metal ion (e.g. Mn2+) and the corresponding PET isotope (e.g. 52gMn), leads to a “cocktail mixture” where both imaging reporters exhibit the same pharmacokinetics. Paramagnetic [55Mn(CDTA)]2- shows an excellent compromise between thermodynamic stability, kinetic inertness and MR contrast enhancement. Therefore, the aim of this study was to develop new PET/MR tracers by labelling CDTA ligands with paramagnetic manganese and the β+-emitter 52gMn. N.c.a. 52gMn (t1/2: 5.6 d; Eβ+: 575.8 keV (29.6%)) was produced by proton irradiation of a natCr target followed by cation-exchange chromatography. CDTA was radiolabelled with n.c.a. 52gMn2+ in NaOAc buffer (pH 6) at RT. The complex was purified by RP-HPLC and its stability tested in PBS and blood plasma at 37°C. The redox stability was assessed by monitoring the T1 relaxation (20 MHz) in HEPES buffer (pH 7.4). A functionalized CDTA ligand was synthesized in 5 steps. [52gMn(CDTA)]2- was quantitatively formed within 30 min at RT. The complex was stable for at least 6 days in PBS and blood plasma at 37°C and no oxidation occurred within 7 months storage at RT. Labelling CDTA with an isotopic 52g/55Mn2+ mixture led to the corresponding bimodal PET/MR tracer. Furthermore, a functionalized CDTA ligand was synthesized with an overall yield of 18-25%. [52g/55Mn(CDTA)]2-, the first manganese-based bimodal PET/MR tracer prepared, exhibits excellent stability towards decomplexation and oxidation. This makes the functionalized CDTA ligand highly suitable for designing PET/MR tracers with high relaxivity or targeting properties.

  19. Authentically radiolabelled Mn(II) complexes as bimodal PET/MR tracers

    International Nuclear Information System (INIS)

    Vanasschen, Christian; Brandt, Marie; Ermert, Johannes; Neumaier, Bernd; Coenen, Heinz H

    2015-01-01

    The development of small molecule bimodal PET/MR tracers is mainly hampered by the lack of dedicated preparation methods. Authentic radiolabelling of MR contrast agents ensures easy access to such probes: a ligand, chelating a paramagnetic metal ion (e.g. Mn2+) and the corresponding PET isotope (e.g. 52gMn), leads to a “cocktail mixture” where both imaging reporters exhibit the same pharmacokinetics. Paramagnetic [55Mn(CDTA)]2- shows an excellent compromise between thermodynamic stability, kinetic inertness and MR contrast enhancement. Therefore, the aim of this study was to develop new PET/MR tracers by labelling CDTA ligands with paramagnetic manganese and the β+-emitter 52gMn. N.c.a. 52gMn (t1/2: 5.6 d; Eβ+: 575.8 keV (29.6%)) was produced by proton irradiation of a natCr target followed by cation-exchange chromatography. CDTA was radiolabelled with n.c.a. 52gMn2+ in NaOAc buffer (pH 6) at RT. The complex was purified by RP-HPLC and its stability tested in PBS and blood plasma at 37°C. The redox stability was assessed by monitoring the T1 relaxation (20 MHz) in HEPES buffer (pH 7.4). A functionalized CDTA ligand was synthesized in 5 steps. [52gMn(CDTA)]2- was quantitatively formed within 30 min at RT. The complex was stable for at least 6 days in PBS and blood plasma at 37°C and no oxidation occurred within 7 months storage at RT. Labelling CDTA with an isotopic 52g/55Mn2+ mixture led to the corresponding bimodal PET/MR tracer. Furthermore, a functionalized CDTA ligand was synthesized with an overall yield of 18-25%. [52g/55Mn(CDTA)]2-, the first manganese-based bimodal PET/MR tracer prepared, exhibits excellent stability towards decomplexation and oxidation. This makes the functionalized CDTA ligand highly suitable for designing PET/MR tracers with high relaxivity or targeting properties.

  20. Heart imaging by cadmium telluride gamma camera European Program 'BIOMED' consortium

    CERN Document Server

    Scheiber, C; Chambron, J; Prat, V; Kazandjan, A; Jahnke, A; Matz, R; Thomas, S; Warren, S; Hage-Hali, M; Regal, R; Siffert, P; Karman, M

    1999-01-01

    Cadmium telluride semiconductor detectors (CdTe) operating at room temperature are attractive for medical imaging because of their good energy resolution providing excellent spatial and contrast resolution. The compactness of the detection system allows the building of small light camera heads which can be used for bedside imaging. A mobile pixellated gamma camera based on 2304 CdTe (pixel size: 3x3 mm, field of view: 15 cmx15 cm) has been designed for cardiac imaging. A dedicated 16-channel integrated circuit has also been designed. The acquisition hardware is fully programmable (DSP card, personal computer-based system). Analytical calculations have shown that a commercial parallel hole collimator will fit the efficiency/resolution requirements for cardiac applications. Monte-Carlo simulations predict that the Moire effect can be reduced by a 15 deg. tilt of the collimator with respect to the detector grid. A 16x16 CdTe module has been built for the preliminary physical tests. The energy resolution was 6.16...

  1. Do carotid MR surface coils affect PET quantification in PET/MR imaging?

    International Nuclear Information System (INIS)

    Willemink, Martin J; Eldib, Mootaz; Leiner, Tim; Fayad, Zahi A; Mani, Venkatesh

    2015-01-01

    To evaluate the effect of surface coils for carotid MR imaging on PET quantification in a clinical simultaneous whole-body PET/MR scanner. A cylindrical phantom was filled with a homogeneous 2L water-FDG mixture at a starting dose of 301.2MBq. Clinical PET/MR and PET/CT systems were used to acquire PET-data without a coil (reference standard) and with two carotid MRI coils (Siemens Special Purpose 8-Channel and Machnet 4-Channel Phased Array). PET-signal attenuation was evaluated with Osirix using 51 (PET/MR) and 37 (PET/CT) circular ROIs. Mean and maximum standardized uptake values (SUVs) were quantified for each ROI. Furthermore, SUVs of PET/MR and PET/CT were compared. For validation, a patient was scanned with an injected dose of 407.7MBq on both a PET/CT and a PET/MR system without a coil and with both coils. PET/MR underestimations were -2.2% (Siemens) and -7.8% (Machnet) for SUVmean, and -1.2% (Siemens) and -3.3% (Machnet) for SUVmax, respectively. For PET/CT, underestimations were -1.3% (Siemens) and -1.4% (Machnet) for SUVmean and -0.5% (both Siemens and Machnet) for SUVmax, respectively using no coil data as reference. Except for PET/CT SUVmax values all differences were significant. SUVs differed significantly between PET/MR and PET/CT with SUVmean values of 0.51-0.55 for PET/MR and 0.68-0.69 for PET/CT, respectively. The patient examination showed that median SUVmean values measured in the carotid arteries decreased from 0.97 without a coil to 0.96 (Siemens) and 0.88 (Machnet). Carotid surface coils do affect attenuation correction in both PET/MR and PET/CT imaging. Furthermore, SUVs differed significantly between PET/MR and PET/CT.

  2. 18F-FDG PET/CT diagnosis of unexpected extracardiac septic embolisms in patients with suspected cardiac endocarditis

    International Nuclear Information System (INIS)

    Bonfiglioli, Rachele; Nanni, Cristina; Morigi, Joshua James; Ambrosini, Valentina; Fanti, Stefano; Graziosi, Maddalena; Rapezzi, Claudio; Trapani, Filippo; Bartoletti, Michele; Tumietto, Fabio; Viale, Pier Luigi; Ferretti, Alice; Rubello, Domenico

    2013-01-01

    Acute infective endocarditis is a potentially life-threatening disease. Its outcome strongly depends on systemic embolization and extracardiac infections. When present, these conditions usually lead to a more aggressive therapeutic approach. However, the diagnosis of peripheral septic embolism is very challenging. 18 F-Fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT has proven to be accurate for the detection of inflammatory diseases and occult infections. The aim of this study was to assess the added value of 18 F-FDG PET/CT in the detection of extracardiac embolisms in the evaluation of patients with suspected valvular endocarditis (VE). Seventy-one patients with suspected infective endocarditis, enrolled between June 2010 and December 2012, underwent 18 F-FDG PET/CT with the standard procedure on a dedicated PET/CT scanner. Extracardiac findings were subsequently evaluated with other imaging procedures. Of the 71 patients with suspicion of infective endocarditis, we found unexpected extracardiac findings in 17 patients (24 %) without any clinical suspicion. Extracardiac findings were subsequently evaluated with other imaging procedures. PET/CT detected unexpected extra sites of infection in 24 % of cases, leading to changes in therapeutic management in a very relevant percentage of patients. These findings may have important therapeutic implications. (orig.)

  3. Evaluation of the PET component of simultaneous [18F]choline PET/MRI in prostate cancer: comparison with [18F]choline PET/CT

    International Nuclear Information System (INIS)

    Wetter, Axel; Lipponer, Christine; Nensa, Felix; Altenbernd, Jens-Christian; Schlosser, Thomas; Lauenstein, Thomas; Heusch, Philipp; Ruebben, Herbert; Bockisch, Andreas; Poeppel, Thorsten; Nagarajah, James

    2014-01-01

    The aim of this study was to evaluate the positron emission tomography (PET) component of [ 18 F]choline PET/MRI and compare it with the PET component of [ 18 F]choline PET/CT in patients with histologically proven prostate cancer and suspected recurrent prostate cancer. Thirty-six patients were examined with simultaneous [ 18 F]choline PET/MRI following combined [ 18 F]choline PET/CT. Fifty-eight PET-positive lesions in PET/CT and PET/MRI were evaluated by measuring the maximum and mean standardized uptake values (SUV max and SUV mean ) using volume of interest (VOI) analysis. A scoring system was applied to determine the quality of the PET images of both PET/CT and PET/MRI. Agreement between PET/CT and PET/MRI regarding SUV max and SUV mean was tested using Pearson's product-moment correlation and Bland-Altman analysis. All PET-positive lesions that were visible on PET/CT were also detectable on PET/MRI. The quality of the PET images was comparable in both groups. Median SUV max and SUV mean of all lesions were significantly lower in PET/MRI than in PET/CT (5.2 vs 6.1, p max of PET/CT and PET/MRI (R = 0.86, p mean of PET/CT and PET/MRI (R = 0.81, p max of PET/CT vs PET/MRI and -1.12 to +2.23 between SUV mean of PET/CT vs PET/MRI. PET image quality of PET/MRI was comparable to that of PET/CT. A highly significant correlation between SUV max and SUV mean was found. Both SUV max and SUV mean were significantly lower in [ 18 F]choline PET/MRI than in [ 18 F]choline PET/CT. Differences of SUV max and SUV mean might be caused by different techniques of attenuation correction. Furthermore, differences in biodistribution and biokinetics of [ 18 F]choline between the subsequent examinations and in the respective organ systems have to be taken into account. (orig.)

  4. Y-90 PET imaging for radiation theragnosis using bootstrap event re sampling

    International Nuclear Information System (INIS)

    Nam, Taewon; Woo, Sangkeun; Min, Gyungju; Kim, Jimin; Kang, Joohyun; Lim, Sangmoo; Kim, Kyeongmin

    2013-01-01

    Surgical resection is the most effective method to recover the liver function. However, Yttrium-90 (Y-90) has been used as a new treatment due to the fact that it can be delivered to the tumors and results in greater radiation exposure to the tumors than using external radiation nowadays since most treatment is palliative in case of unresectable stage of hepatocellular carcinoma (HCC). Recently, Y-90 has been received much interest and studied by many researchers. Imaging of Y-90 has been conducted using most commonly gamma camera but PET imaging is required due to low sensitivity and resolution. The purpose of this study was to assess statistical characteristics and to improve count rate of image for enhancing image quality by using nonparametric bootstrap method. PET data was able to be improved using non-parametric bootstrap method and it was verified with showing improved uniformity and SNR. Uniformity showed more improvement under the condition of low count rate, i.e. Y-90, in case of phantom and also uniformity and SNR showed improvement of 15.6% and 33.8% in case of mouse, respectively. Bootstrap method performed in this study for PET data increased count rate of PET image and consequentially time for acquisition time can be reduced. It will be expected to improve performance for diagnosis

  5. Design and construction of a small animal PET/CT scanner combining scintillation Phoswich modules and hybrid pixels detectors

    International Nuclear Information System (INIS)

    Nicol, St.

    2010-07-01

    The pathway that has been followed by the imXgam team at CPPM was to combine on a single rotating device the detector modules of the small animal PET scanner ClearPET with a photon counting X-ray detector in order to perform simultaneous acquisition of images from the anatomy (X-ray CT) and from the metabolic function (PET) of the common field-of-view. A preliminary study of the hybrid imaging system ClearPET/XPAD3 carried out using Gate led us to form a new PET detection assembly based on 21 Phoswich modules, to fix the design of the PET/CT device, as well as to study and solve the difficulties arising from simultaneous hybrid imaging. Last but not least, the simulation tool also allowed us for thinking how well such a system could judiciously use the spatial and temporal correlations between anatomic and functional information. From an instrumentation point of view, we succeeded to set up the ClearPET/XPAD3 prototype. Once both imaging systems were operational individually, we demonstrated on one side that the ClearPET prototype was perfectly capable of performing correctly in simultaneous acquisition conditions, providing that the detector modules were appropriately shielded. On the other side, the new generation of the hybrid pixel camera using the XPAD3-S chip proved to be quite promising given the good quality of the first reconstructed images. Finally, the proof of concept of simultaneous PET/CT data acquisition was made using a sealed positron source and an X-ray tube. (author)

  6. External radioactive markers for PET data-driven respiratory gating in positron emission tomography.

    Science.gov (United States)

    Büther, Florian; Ernst, Iris; Hamill, James; Eich, Hans T; Schober, Otmar; Schäfers, Michael; Schäfers, Klaus P

    2013-04-01

    Respiratory gating is an established approach to overcoming respiration-induced image artefacts in PET. Of special interest in this respect are raw PET data-driven gating methods which do not require additional hardware to acquire respiratory signals during the scan. However, these methods rely heavily on the quality of the acquired PET data (statistical properties, data contrast, etc.). We therefore combined external radioactive markers with data-driven respiratory gating in PET/CT. The feasibility and accuracy of this approach was studied for [(18)F]FDG PET/CT imaging in patients with malignant liver and lung lesions. PET data from 30 patients with abdominal or thoracic [(18)F]FDG-positive lesions (primary tumours or metastases) were included in this prospective study. The patients underwent a 10-min list-mode PET scan with a single bed position following a standard clinical whole-body [(18)F]FDG PET/CT scan. During this scan, one to three radioactive point sources (either (22)Na or (18)F, 50-100 kBq) in a dedicated holder were attached the patient's abdomen. The list mode data acquired were retrospectively analysed for respiratory signals using established data-driven gating approaches and additionally by tracking the motion of the point sources in sinogram space. Gated reconstructions were examined qualitatively, in terms of the amount of respiratory displacement and in respect of changes in local image intensity in the gated images. The presence of the external markers did not affect whole-body PET/CT image quality. Tracking of the markers led to characteristic respiratory curves in all patients. Applying these curves for gated reconstructions resulted in images in which motion was well resolved. Quantitatively, the performance of the external marker-based approach was similar to that of the best intrinsic data-driven methods. Overall, the gain in measured tumour uptake from the nongated to the gated images indicating successful removal of respiratory motion

  7. One year report from the T.R.P. A.P.-H.P. center; Impact of the PET with [18F] - FDG on the medical decision in oncology

    International Nuclear Information System (INIS)

    Talbot, J.N.; Montravers, F.; Grahek, D.; Kerrou, K.; Younsi, N.; Cailleux, N.; Vaylet, C.; Nguyen, C.; Zanotti, P.; Itti, E.; Malek, Z.; Peker, C.; Toubert, M.E.; Benelhadj, S.; Duet, M.

    2001-01-01

    The clinical usefulness of FDG-PET has been recognised by the French Medicine Agency since 1998. A PET centre equipped with a dedicated camera suited for oncological routine examination has been opened at the beginning of the year 2000, associating 5 hospitals and their network of oncologists. The present article has several aims. It reports quantitatively, monthly and indication by indication on the number of examinations performed during the opening year, to give possibly helpful information to the future PET centres in France. During the year 2000, 656 FDG-PET examination has been performed in 605 patients, who dwelt in Paris for 28% of them, in the rest of Ile de France region for 47 %, in other French regions or even abroad for 25%. 83% of the patients came has out-patients. The article also briefly enumerates the clinical study protocols that have been designed and approved by the Scientific Committee and started during the year 2000, the inclusions being still underway. Finally, the article includes the main results of our study on the clinical impact of FDG-PET. Such results have been already published outside France: in a meta-analysis involving more than 5000 patients, the modification rate of patients' management was calculated to be 30%. However, the evaluation of this impact from the referring clinician's perspective that seems more impartial has only been performed recently by two Californian teams by means of a questionnaire retrospective survey. We used the same questionnaire (translated into French language) and the same methodology. One questionnaire was sent to the referring physician for each of the 476 who underwent a routine FDG-PET study for a registered clinical indication during the year 2000. 348 responses (73%) were received and included in the study. Globally, the disease was upstaged in 26% of the cases and down-staged in 9%. Inter-modality management changes (change from a scheduled therapeutic modality for a different one) were

  8. [Principles of PET].

    Science.gov (United States)

    Beuthien-Baumann, B

    2018-05-01

    Positron emission tomography (PET) is a procedure in nuclear medicine, which is applied predominantly in oncological diagnostics. In the form of modern hybrid machines, such as PET computed tomography (PET/CT) and PET magnetic resonance imaging (PET/MRI) it has found wide acceptance and availability. The PET procedure is more than just another imaging technique, but a functional method with the capability for quantification in addition to the distribution pattern of the radiopharmaceutical, the results of which are used for therapeutic decisions. A profound knowledge of the principles of PET including the correct indications, patient preparation, and possible artifacts is mandatory for the correct interpretation of PET results.

  9. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    International Nuclear Information System (INIS)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah

    2014-01-01

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after 18 F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast-enhanced PET

  10. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah [Yeungnam Univ. Hospital, Daegu (Korea, Republic of)

    2014-03-15

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after {sup 18}F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast

  11. Translocator Protein-18 kDa (TSPO Positron Emission Tomography (PET Imaging and Its Clinical Impact in Neurodegenerative Diseases

    Directory of Open Access Journals (Sweden)

    Anne-Claire Dupont

    2017-04-01

    Full Text Available In vivo exploration of activated microglia in neurodegenerative diseases is achievable by Positron Emission Tomography (PET imaging, using dedicated radiopharmaceuticals targeting the translocator protein-18 kDa (TSPO. In this review, we emphasized the major advances made over the last 20 years, thanks to TSPO PET imaging, to define the pathophysiological implication of microglia activation and neuroinflammation in neurodegenerative diseases, including Parkinson’s disease, Huntington’s disease, dementia, amyotrophic lateral sclerosis, multiple sclerosis, and also in psychiatric disorders. The extent and upregulation of TSPO as a molecular biomarker of activated microglia in the human brain is now widely documented in these pathologies, but its significance, and especially its protective or deleterious action regarding the disease’s stage, remains under debate. Thus, we exposed new and plausible suggestions to enhance the contribution of TSPO PET imaging for biomedical research by exploring microglia’s role and interactions with other cells in brain parenchyma. Multiplex approaches, associating TSPO PET radiopharmaceuticals with other biomarkers (PET imaging of cellular metabolism, neurotransmission or abnormal protein aggregates, but also other imaging modalities, and peripheral cytokine levels measurement and/or metabolomics analysis was considered. Finally, the actual clinical impact of TSPO PET imaging as a routine biomarker of neuroinflammation was put into perspective regarding the current development of diagnostic and therapeutic strategies for neurodegenerative diseases.

  12. Lung PET scan

    Science.gov (United States)

    ... Chest PET scan; Lung positron emission tomography; PET - chest; PET - lung; PET - tumor imaging; ... Grainger & Allison's Diagnostic Radiology: A Textbook of Medical Imaging . 6th ed. Philadelphia, ...

  13. Dedicated accelerator and microprobe line

    International Nuclear Information System (INIS)

    Malmqvist, K.G.; Hylten, G.; Hult, M.; Haakansson, K.; Knox, J.M.; Larsson, N.P.O.; Nilsson, C.; Pallon, J.; Schofield, R.; Swietlicki, E.; Tapper, U.A.S.; Yang Changyi

    1993-01-01

    The development of a dedicated facility for nuclear microprobe analysis and the experiences from using it are discussed. The general properties of the present Lund nuclear microprobe will be described and the advantages of using a dedicated accelerator discussed. (orig.)

  14. Simultaneous PET/MRI with 13C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification

    DEFF Research Database (Denmark)

    Hansen, Adam E.; Andersen, Flemming L.; Henriksen, Sarah T.

    2016-01-01

    Background: Integrated PET/MRI with hyperpolarized 13C magnetic resonance spectroscopic imaging (13C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented...... for a clinical whole-body system using simultaneous 1 H-MRI and PET but never for 13C-MRSI and PET. Here, the feasibility of simultaneous PET and 13C-MRSI as well as hyperpolarized 13C-MRSI in an integrated whole-body PET/MRI hybrid scanner is evaluated using phantom experiments. Methods: Combined PET and 13C......-MRSI phantoms including a NEMA [18F]-FDG phantom, 13C-acetate and 13C-urea sources, and hyperpolarized 13C-pyruvate were imaged repeatedly with PET and/or 13C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET...

  15. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs

  16. Positron Emission Tomography (PET)

    Science.gov (United States)

    Welch, M. J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.

  17. Positron Emission Tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  18. {sup 18}F-FDG PET/CT diagnosis of unexpected extracardiac septic embolisms in patients with suspected cardiac endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Bonfiglioli, Rachele; Nanni, Cristina; Morigi, Joshua James; Ambrosini, Valentina; Fanti, Stefano [Azienda Ospedaliero-Universitaria di Bologna, Policlinico S. Orsola-Malpighi, Nuclear Medicine, Bologna (Italy); Graziosi, Maddalena; Rapezzi, Claudio [Azienda Ospedaliero-Universitaria di Bologna, Policlinico S. Orsola-Malpighi, Cardiology, Bologna (Italy); Trapani, Filippo; Bartoletti, Michele; Tumietto, Fabio; Viale, Pier Luigi [Azienda Ospedaliero-Universitaria di Bologna, Policlinico S. Orsola-Malpighi, Infective Diseases, Bologna (Italy); Ferretti, Alice; Rubello, Domenico [Azienda Ospedaliera S. Maria della Misericordia, Nuclear Medicine, Radiology, Neuroradiology, Medical Physics, Rovigo (Italy)

    2013-08-15

    Acute infective endocarditis is a potentially life-threatening disease. Its outcome strongly depends on systemic embolization and extracardiac infections. When present, these conditions usually lead to a more aggressive therapeutic approach. However, the diagnosis of peripheral septic embolism is very challenging. {sup 18}F-Fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT has proven to be accurate for the detection of inflammatory diseases and occult infections. The aim of this study was to assess the added value of {sup 18}F-FDG PET/CT in the detection of extracardiac embolisms in the evaluation of patients with suspected valvular endocarditis (VE). Seventy-one patients with suspected infective endocarditis, enrolled between June 2010 and December 2012, underwent {sup 18}F-FDG PET/CT with the standard procedure on a dedicated PET/CT scanner. Extracardiac findings were subsequently evaluated with other imaging procedures. Of the 71 patients with suspicion of infective endocarditis, we found unexpected extracardiac findings in 17 patients (24 %) without any clinical suspicion. Extracardiac findings were subsequently evaluated with other imaging procedures. PET/CT detected unexpected extra sites of infection in 24 % of cases, leading to changes in therapeutic management in a very relevant percentage of patients. These findings may have important therapeutic implications. (orig.)

  19. Indeterminate findings on oncologic PET/CT: What difference dose PET/MRI make?

    Energy Technology Data Exchange (ETDEWEB)

    Fraum, Tyler J.; Fowler, Kathryn J.; McConathy, Jonathan; Dehdashti, Farokh [Mallinckrodt Institute of Radiology, Washington University School of Medicine, Saint Louis (United States)

    2016-12-15

    Positron emission tomography/computed tomography (PET/CT) with 2-deoxy-2-[{sup 18}F]fluoro-D-glucose (FDG) has become the standard of care for the initial staging and subsequent treatment response assessment of many different malignancies. Despite this success, PET/CT is often supplemented by MRI to improve assessment of local tumor invasion and to facilitate detection of lesions in organs with high background FDG uptake. Consequently, PET/MRI has the potential to expand the clinical value of PET examinations by increasing reader certainty and reducing the need for subsequent imaging. This study evaluates the ability of FDG-PET/MRI to clarify findings initially deemed indeterminate on clinical FDG-PET/CT studies. A total of 190 oncology patients underwent whole-body PET/CT, immediately followed by PET/MRI utilizing the same FDG administration. Each PET/CT was interpreted by our institution's nuclear medicine service as a standard-of-care clinical examination. Review of these PET/CT reports identified 31 patients (16 %) with indeterminate findings. Two readers evaluated all 31 PET/CT studies, followed by the corresponding PET/MRI studies. A consensus was reached for each case, and changes in interpretation directly resulting from PET/MRI review were recorded. Interpretations were then correlated with follow-up imaging, pathology results, and other diagnostic studies. In 18 of 31 cases with indeterminate findings on PET/CT, PET/MRI resulted in a more definitive interpretation by facilitating the differentiation of infection/inflammation from malignancy (15/18), the accurate localization of FDG-avid lesions (2/18), and the characterization of incidental non-FDG-avid solid organ lesions (1/18). Explanations for improved reader certainty with PET/MRI included the superior soft tissue contrast of MRI and the ability to assess cellular density with diffusion-weighted imaging. The majority (12/18) of such cases had an appropriate standard of reference; in all 12 cases

  20. Indeterminate findings on oncologic PET/CT: What difference dose PET/MRI make?

    International Nuclear Information System (INIS)

    Fraum, Tyler J.; Fowler, Kathryn J.; McConathy, Jonathan; Dehdashti, Farokh

    2016-01-01

    Positron emission tomography/computed tomography (PET/CT) with 2-deoxy-2-["1"8F]fluoro-D-glucose (FDG) has become the standard of care for the initial staging and subsequent treatment response assessment of many different malignancies. Despite this success, PET/CT is often supplemented by MRI to improve assessment of local tumor invasion and to facilitate detection of lesions in organs with high background FDG uptake. Consequently, PET/MRI has the potential to expand the clinical value of PET examinations by increasing reader certainty and reducing the need for subsequent imaging. This study evaluates the ability of FDG-PET/MRI to clarify findings initially deemed indeterminate on clinical FDG-PET/CT studies. A total of 190 oncology patients underwent whole-body PET/CT, immediately followed by PET/MRI utilizing the same FDG administration. Each PET/CT was interpreted by our institution's nuclear medicine service as a standard-of-care clinical examination. Review of these PET/CT reports identified 31 patients (16 %) with indeterminate findings. Two readers evaluated all 31 PET/CT studies, followed by the corresponding PET/MRI studies. A consensus was reached for each case, and changes in interpretation directly resulting from PET/MRI review were recorded. Interpretations were then correlated with follow-up imaging, pathology results, and other diagnostic studies. In 18 of 31 cases with indeterminate findings on PET/CT, PET/MRI resulted in a more definitive interpretation by facilitating the differentiation of infection/inflammation from malignancy (15/18), the accurate localization of FDG-avid lesions (2/18), and the characterization of incidental non-FDG-avid solid organ lesions (1/18). Explanations for improved reader certainty with PET/MRI included the superior soft tissue contrast of MRI and the ability to assess cellular density with diffusion-weighted imaging. The majority (12/18) of such cases had an appropriate standard of reference; in all 12 cases, the

  1. The use of low cost compact cameras with focus stacking functionality in entomological digitization projects

    Directory of Open Access Journals (Sweden)

    Jan Mertens

    2017-10-01

    Full Text Available Digitization of specimen collections has become a key priority of many natural history museums. The camera systems built for this purpose are expensive, providing a barrier in institutes with limited funding, and therefore hampering progress. An assessment is made on whether a low cost compact camera with image stacking functionality can help expedite the digitization process in large museums or provide smaller institutes and amateur entomologists with the means to digitize their collections. Images of a professional setup were compared with the Olympus Stylus TG-4 Tough, a low-cost compact camera with internal focus stacking functions. Parameters considered include image quality, digitization speed, price, and ease-of-use. The compact camera’s image quality, although inferior to the professional setup, is exceptional considering its fourfold lower price point. Producing the image slices in the compact camera is a matter of seconds and when optimal image quality is less of a priority, the internal stacking function omits the need for dedicated stacking software altogether, further decreasing the cost and speeding up the process. In general, it is found that, aware of its limitations, this compact camera is capable of digitizing entomological collections with sufficient quality. As technology advances, more institutes and amateur entomologists will be able to easily and affordably catalogue their specimens.

  2. PET and PET/CT in tumour of undetermined origin; PET y PET/CT en tumor de origen indeterminado

    Energy Technology Data Exchange (ETDEWEB)

    Garcia O, J R [Nuclear Medicine and Molecular Imaging, PET/CT, Centro Medico ABC, Mexico D.F. (Mexico)

    2007-07-01

    In this presentation the following conclusions were obtained regarding the use of PET and PET/CT in patient with cancer of unknown primary: 1. Detection of the primary one in 1/3 at 1/2 of patient. 2. It detects metastases in other places in 50%. 3. It changes the initial therapy planned in 1/3 at 1/2 of patient. 4. Useful in initial phases of protocol study to limit the other procedures. After standard evaluation. Before advanced protocol. 5. PET/CT study increases the % of primary detection, although in a non significant way vs. PET. 6. They are required more studies to value their utility to a more objective manner. (Author)

  3. Simultaneous PET/MRI with (13)C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification.

    Science.gov (United States)

    Hansen, Adam E; Andersen, Flemming L; Henriksen, Sarah T; Vignaud, Alexandre; Ardenkjaer-Larsen, Jan H; Højgaard, Liselotte; Kjaer, Andreas; Klausen, Thomas L

    2016-12-01

    Integrated PET/MRI with hyperpolarized (13)C magnetic resonance spectroscopic imaging ((13)C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented for a clinical whole-body system using simultaneous (1)H-MRI and PET but never for (13)C-MRSI and PET. Here, the feasibility of simultaneous PET and (13)C-MRSI as well as hyperpolarized (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is evaluated using phantom experiments. Combined PET and (13)C-MRSI phantoms including a NEMA [(18)F]-FDG phantom, (13)C-acetate and (13)C-urea sources, and hyperpolarized (13)C-pyruvate were imaged repeatedly with PET and/or (13)C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET trues; and (13)C-MRSI signal-to-noise ratio (SNR) for urea and acetate phantoms. Differences between measurement conditions were evaluated using t tests. PET and (13)C-MRSI data acquisition could be performed simultaneously without any discernible artifacts. The average difference in PET activity between acquisitions with and without simultaneous (13)C-MRSI was 0.83 (largest sphere) and -0.76 % (background). The average difference in net trues was -0.01 %. The average difference in (13)C-MRSI SNR between acquisitions with and without simultaneous PET ranged from -2.28 to 1.21 % for all phantoms and measurement conditions. No differences were significant. The system was capable of (13)C-MRSI of hyperpolarized (13)C-pyruvate. Simultaneous PET and (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is feasible. Phantom experiments showed that possible interference effects introduced by acquiring data from the two modalities simultaneously are small and non-significant. Further experiments can now investigate the benefits of simultaneous PET and

  4. Silicon Photomultipliers (SiPM) as novel photodetectors for PET

    International Nuclear Information System (INIS)

    Del Guerra, Alberto; Belcari, Nicola; Giuseppina Bisogni, Maria; Corsi, Francesco; Foresta, Maurizio; Guerra, Pedro; Marcatili, Sara; Santos, Andres; Sportelli, Giancarlo

    2011-01-01

    Next generation PET scanners should fulfill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultipliers (SiPMs) is proposed for the construction of a 4D-PET module of 4.8x4.8 cm 2 aimed to replace the standard PMT based PET block detector. The module will be based on a LYSO continuous crystal read on two faces by Silicon Photomultipliers. A high granularity detection surface made by SiPM matrices of 1.5 mm pitch will be used for the x-y photon hit position determination with submillimetric accuracy, while a low granularity surface constituted by 16 mm 2 SiPM pixels will provide the fast timing information (t) that will be used to implement the Time of Flight technique (TOF). The spatial information collected by the two detector layers will be combined in order to measure the Depth of Interaction (DOI) of each event (z). The use of large area multi-pixel Silicon Photomultiplier (SiPM) detectors requires the development of a multichannel Data Acquisition system (DAQ) as well as of a dedicated front-end in order not to degrade the intrinsic detector capabilities and to manage many channels. The paper describes the progress made on the development of the proof of principle module under construction at the University of Pisa.

  5. PET imaging approaches for inflammatory lung diseases: Current concepts and future directions

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Delphine L., E-mail: chend@wustl.edu [Divisions of Radiological Sciences and Nuclear Medicine, Mallinckrodt Institute of Radiology, Campus Box 8225, 510S, Kingshighway Blvd, St. Louis, MO (United States); Schiebler, Mark L. [Department of Radiology, UW-Madison School of Medicine and Public Heath, Madison, WI (United States); Goo, Jin Mo [Department of Radiology, Seoul National University, Seoul (Korea, Republic of); Beek, Edwin J.R. van [Clinical Research Imaging Centre, Queen’s Medical Research Institute, University of Edinburgh, Edinburgh (United Kingdom)

    2017-01-15

    Highlights: • Positron emission tomography can provide molecular information inflammatory lung disease mechanisms and assess targeted treatment responses. • {sup 18}F-Fluorodeoxyglucose, {sup 18}F-(+/−)NOS, and {sup 18}F-fluciclatide have potential for serving as biomarkers of inflammation and fibrosis. • PET can complement computed tomography and magnetic resonance imaging to improve our understanding of inflammatory lung disease mechanisms. - Abstract: Inflammatory lung disease is one of the most common clinical scenarios, and yet, it is often poorly understood. Inflammatory lung disorders, such as chronic obstructive pulmonary diseases, which are causing significant mortality and morbidity, have limited therapeutic options. Recently, new treatments have become available for pulmonary fibrosis. This review article will describe the new insights that are starting to be gained from positron emission tomography (PET) methods, by targeting molecular processes using dedicated radiotracers. Ultimately, this should aid in deriving better pathophysiological classification of these disorders, which will ultimately result in better evaluation of novel therapies.

  6. 18F-FDG hybrid PET in patients with suspected spondylitis

    International Nuclear Information System (INIS)

    Gratz, S.; Behr, T.M.; Behe, M.; Doerner, J.; Fischer, U.; Grabbe, E.; Altenvoerde, G.; Meller, J.; Becker, W.

    2002-01-01

    This study investigated the value of fluorine-18 2'-deoxy-2-fluoro-D-glucose (FDG) imaging with a double-headed gamma camera operated in coincidence (hybrid PET) detection mode in patients with suspected spondylitis. Comparison was made with conventional nuclear medicine imaging modalities and magnetic resonance imaging (MRI). Sixteen patients with suspected spondylitis (nine male, seven female, mean age 59 years) prospectively underwent FDG hybrid PET (296 MBq) and MRI. For intra-individual comparison, the patients were also imaged with technetium-99m methylene diphosphonate (MDP) (555 MBq) (n=13) and/or gallium-67 citrate (185 MBq) (n=11). For FDG hybrid PET, two or three transverse scans were performed. Ratios of infected (target) to non-infected (background) (T/B) vertebral bodies were calculated. MR images were obtained of the region of interest. Patients found positive for spondylitis with MRI and/or FDG hybrid PET underwent surgical intervention and histological grading of the individual infected foci. Twelve out of 16 patients were found to be positive for spondylitis. Independent of the grade of infection and the location in the spine, all known infected vertebrae (n=23, 9 thoracic, 12 lumbar, 2 sacral) were detected by FDG hybrid PET. T/B ratios higher than 1.45±0.05 (at 1 h p.i.) were indicative of infectious disease, whereas ratios below this value were found in cases of degenerative change. FDG hybrid PET was superior to MRI in patients who had a history of surgery and suffered from a high-grade infection in combination with paravertebral abscess formation (n=2; further computed tomography was needed) and in those with low-grade spondylitis (n=2, no oedema) or discitis (n=2, mild oedema). False-positive 67 Ga citrate images (n=5: 2 spondylodiscitis, 1 aortitis, 1 pleuritis, 1 pulmonary tuberculosis) and 99m Tc-MDP SPET (n=4: 1 osteoporosis, 2 spondylodiscitis, 1 fracture) were equally well detected by FDG hybrid PET and MRI. No diagnostic problems

  7. High throughput static and dynamic small animal imaging using clinical PET/CT: potential preclinical applications

    International Nuclear Information System (INIS)

    Aide, Nicolas; Desmonts, Cedric; Agostini, Denis; Bardet, Stephane; Bouvard, Gerard; Beauregard, Jean-Mathieu; Roselt, Peter; Neels, Oliver; Beyer, Thomas; Kinross, Kathryn; Hicks, Rodney J.

    2010-01-01

    The objective of the study was to evaluate state-of-the-art clinical PET/CT technology in performing static and dynamic imaging of several mice simultaneously. A mouse-sized phantom was imaged mimicking simultaneous imaging of three mice with computation of recovery coefficients (RCs) and spillover ratios (SORs). Fifteen mice harbouring abdominal or subcutaneous tumours were imaged on clinical PET/CT with point spread function (PSF) reconstruction after injection of [18F]fluorodeoxyglucose or [18F]fluorothymidine. Three of these mice were imaged alone and simultaneously at radial positions -5, 0 and 5 cm. The remaining 12 tumour-bearing mice were imaged in groups of 3 to establish the quantitative accuracy of PET data using ex vivo gamma counting as the reference. Finally, a dynamic scan was performed in three mice simultaneously after the injection of 68 Ga-ethylenediaminetetraacetic acid (EDTA). For typical lesion sizes of 7-8 mm phantom experiments indicated RCs of 0.42 and 0.76 for ordered subsets expectation maximization (OSEM) and PSF reconstruction, respectively. For PSF reconstruction, SOR air and SOR water were 5.3 and 7.5%, respectively. A strong correlation (r 2 = 0.97, p 2 = 0.98; slope = 0.89, p 2 = 0.96; slope = 0.62, p 68 Ga-EDTA dynamic acquisition. New generation clinical PET/CT can be used for simultaneous imaging of multiple small animals in experiments requiring high throughput and where a dedicated small animal PET system is not available. (orig.)

  8. Dual cardiac-respiratory gated PET: implementation and results from a feasibility study

    International Nuclear Information System (INIS)

    Martinez-Moeller, Axel; Zikic, Darko; Navab, Nassir; Botnar, Rene M.; Bundschuh, Ralph A.; Ziegler, Sibylle I.; Schwaiger, Markus; Nekolla, Stephan G.; Howe, William

    2007-01-01

    significant elastic component and was of the same magnitude as the spatial resolution of current PET cameras. (orig.)

  9. Pet Allergy Quiz

    Science.gov (United States)

    ... Treatments ▸ Allergies ▸ Pet Allergy ▸ Pet Allergy Quiz Share | Pet Allergy Quiz More than half of U.S. households ... cat family. Yet, millions of people suffer from pet allergies. Take this quiz to test your knowledge ...

  10. Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR.

    Science.gov (United States)

    Catalano, Onofrio A; Coutinho, Artur M; Sahani, Dushyant V; Vangel, Mark G; Gee, Michael S; Hahn, Peter F; Witzel, Thomas; Soricelli, Andrea; Salvatore, Marco; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce R; Gervais, Debra

    2017-04-01

    Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.

  11. ROKCY-12 (KCCH PET-dedicated cyclotron): main features and improvements

    International Nuclear Information System (INIS)

    Chai, J. S.; Kim, Y. S.; Yang, Y. T.; Jung, I. S.; Hong, S. S.; Lee, M. Y.; Jang, H. S.; Kim, J. H.

    2002-01-01

    In this paper, we describe the development of 13 MeV cyclotron (ROKCY-12) that can be used for a Position Emission Tomography(PET) purpose. This cyclotron with a maximum beam energy of 13 MeV can produce radio isotopes especially 18 F which has a relatively short half lifetime of 110 minutes. First, we show the beam characteristics can be used to carry out the operation of ROCKY-12. Based on this, a computer program has been developed to determine main cyclotron parameters such as cyclotron magnet, RF system, ion source, vacuum system and other cyclotron operation parameters. And then we show the result of design and manufacturing feature of ROKCY-12. By using this design program, one can determines magnet yoke geometry and the average magnetic fields etc. And then the three-dimensional computer program OPERA-3D has been invoked to determine magnet pole tips. Validity of the design can be seen by investigating magnetic fields, radial and vertical focusing frequencies as a function of the beam energy. In this paper, we show the results of cyclotron beam by ROCKY-12. We designed 77.3 MHz RF system and ion source system. We tested RF resonance each coupling methods. We show the result of RF design and prototype operation. Developed ion source is PIG type. We described our design methods and implementation. We report the result of getting negative hydrogen ion. Cyclotron controller asks inputs of every sensor and output of every instrument for notifying current condition to operator. It has independent controllers, for example DC power supply, vacuum system, beam profile system, beam extraction system, RF system, ion source, cooling unit and so on. Basically, each control system uses RS-485 for communication to main control computer. Consumers reward products and services that feature quality, originality, a distinct personality and charm. The International Standardization Organization (ISO) requires, as its mission, that we achieve competitive superiority by

  12. A robotic system for 18F-FMISO PET-guided intratumoral pO2 measurements.

    Science.gov (United States)

    Chang, Jenghwa; Wen, Bixiu; Kazanzides, Peter; Zanzonico, Pat; Finn, Ronald D; Fichtinger, Gabor; Ling, C Clifton

    2009-11-01

    An image-guided robotic system was used to measure the oxygen tension (pO2) in rodent tumor xenografts using interstitial probes guided by tumor hypoxia PET images. Rats with approximately 1 cm diameter tumors were anesthetized and immobilized in a custom-fabricated whole-body mold. Imaging was performed using a dedicated small-animal PET scanner (R4 or Focus 120 microPET) approximately 2 h after the injection of the hypoxia tracer 18F-fluoromisonidazole (18F-FMISO). The coordinate systems of the robot and PET were registered based on fiducial markers in the rodent bed visible on the PET images. Guided by the 3D microPET image set, measurements were performed at various locations in the tumor and compared to the corresponding 18F-FMISO image intensity at the respective measurement points. Experiments were performed on four tumor-bearing rats with 4 (86), 3 (80), 7 (162), and 8 (235) measurement tracks (points) for each experiment. The 18F-FMISO image intensities were inversely correlated with the measured pO2, with a Pearson coefficient ranging from -0.14 to -0.97 for the 22 measurement tracks. The cumulative scatterplots of pO2 versus image intensity yielded a hyperbolic relationship, with correlation coefficients of 0.52, 0.48, 0.64, and 0.73, respectively, for the four tumors. In conclusion, PET image-guided pO2 measurement is feasible with this robot system and, more generally, this system will permit point-by-point comparison of physiological probe measurements and image voxel values as a means of validating molecularly targeted radiotracers. Although the overall data fitting suggested that 18F-FMISO may be an effective hypoxia marker, the use of static 18F-FMISO PET postinjection scans to guide radiotherapy might be problematic due to the observed high variation in some individual data pairs from the fitted curve, indicating potential temporal fluctuation of oxygen tension in individual voxels or possible suboptimal imaging time postadministration of hypoxia

  13. TOF-PET/MR和TOF-PET/CT在体部恶性肿瘤SUVmax值的比较%Comparision of SUVmax of TOF-PET/MR and TOF-PET/CT in body malignant tumor

    Institute of Scientific and Technical Information of China (English)

    宋天彬; 卢洁; 崔碧霄; 马杰; 杨宏伟; 马蕾; 梁志刚

    2017-01-01

    目的 探讨时间飞行(TOF)技术PET/CT和PET/MR检查体部恶性病变SUVmax值的一致性.方法 回顾性分析接受TOF-PET/CT和TOF-PET/MR检查的体部恶性肿瘤患者20例,分为先PET/CT后PET/MR组和先PET/MR后PET/CT组,每组10例.采用Bland-Altma图评价两次检查病灶SUVmax值的一致性,采用多因素方差分析评价扫描顺序和机器类型对病灶的SUVmax测量值的影响.结果 TOF-PET/CT与TOF-PET/MR检查病灶的SUVmax值有较好的一致性[先PET/CT后PET/MR组:均值差为3.06,95%CI(-7.5,13.6),先PET/MR后PET/CT组:均值差3.0,95%CI(-2.4,8.3)].扫描顺序对于恶性病灶的SUVmax有影响(F=46.00,P<0.001),而机器类型对恶性病灶的SUVmax值无影响(F=0.005,P=0.95).结论 TOF-PET/MR和TOF-PET/CT在体部恶性病变SUVmax值测量方面具有相当的诊断价值,且延迟显像SUVmax的增加与采集时间有关,而与检查机器类型无关.%Objective To explore the consistency of time-of-flight (TOF) technology of PET/MRI and PET/CT for max standardized uptake value (SUVmax) of body malignant tumors.Methods A retrospective analysis of TOF-PET/CT and TOF-PET/MR imaging data about twenty patients with body malignant tumors was performed.Patients were divided into two groups (each n=10),including PET/CT first and sequentially PET/MR group and PET/MR first and sequentially PET/CT group.Bland-Altman figure was used to evaluate consistency of SUVmax of malignant lesions between TOF-PET/CT and TOF-PET/MR.Multi-way ANOVA was used to analysis effect of machine type and exam order on SUVmaxof malignant lesions in TOF-PET/CT and TOF-PET/MR.Results SUVmax of malignant lesions in TOF-PET/CT and TOF-PET/MR had good consistency in two groups (PET/CT first and sequentially PET/MR group:Mean difference was 3.06,95%CI was [-7.5,13.6];PET/MR first and sequentially PET/CT group:Mean difference was 3.0,95%CI was [-2.4,8.3]).SUVmax was not influenced by machine type (F=0.005,P=0.95),but exam order (F=46.00,P<0

  14. Neuronal pathology in deep grey matter structures: a multimodal imaging analysis combining PET and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Bosque-Freeman, L.; Leroy, C.; Galanaud, D.; Sureau, F.; Assouad, R.; Tourbah, A.; Papeix, C.; Comtat, C.; Trebossen, R.; Lubetzki, C.; Delforge, J.; Bottlaender, M.; Stankoff, B. [Serv. Hosp. Frederic Joliot, Orsay (France)

    2009-07-01

    Objective: To assess neuronal damage in deep gray matter structures by positron emission tomography (PET) using [{sup 11}C]-flumazenil (FMZ), a specific central benzodiazepine receptor antagonist, and [{sup 18}F]-fluorodeoxyglucose (FDG), which reflects neuronal metabolism. To compare results obtained by PET and those with multimodal magnetic resonance imaging (MRI). Background: It is now accepted that neuronal injury plays a crucial role in the occurrence and progression of neurological disability in multiple sclerosis (MS). To date, available MRI techniques do not specifically assess neuronal damage, but early abnormalities, such as iron deposition or atrophy, have been described in deep gray matter structures. Whether those MRI modifications correspond to neuronal damage remains to be further investigated. Materials and methods: Nine healthy volunteers were compared to 10 progressive and 9 relapsing remitting (RR) MS patients. Each subject performed two PET examinations with [{sup 11}C]-FMZ and [{sup 18}F]-FDG, on a high resolution research tomograph dedicated to brain imaging (Siemens Medical Solution, spatial resolution of 2.5 mm). Deep gray matter regions were manually segmented on T1-weighted MR images with the mutual information algorithm (www.brainvisa.info), and co-registered with PET images. A multimodal MRI including T1 pre and post gadolinium, T2-proton density sequences, magnetization transfer, diffusion tensor, and protonic spectroscopy was also performed for each subject. Results: On PET with [{sup 11}C]-FMZ, there was a pronounced decrease in receptor density for RR patients in all deep gray matter structures investigated, whereas the density was unchanged or even increased in the same regions for progressive patients. Whether the different patterns between RR and progressive patients reflect distinct pathogenic mechanisms is currently investigated by comparing PET and multimodal MRI results. Conclusion: Combination of PET and multimodal MR imaging

  15. Usefulness of 18FDG-PET in epilepsy. Methods and indications

    International Nuclear Information System (INIS)

    Chassoux, F.

    2009-01-01

    Positron emission tomography (PET) using 18-fluorodeoxyglucose ( 18 FDG) is currently used in pre surgical work-up for drug-resistant partial epilepsies in children as in adults, in addition to MRI. Recent cameras with less than 5 mm spatial resolution allow to obtain thin slices (about 2 mm thickness) in 3D planes. 18 FDG is intravenously injected at the mean dose of 3 MBq/kg of body weight in inter-ictal and resting state, in a quiet, dimly lit environment and careful monitoring for head movements and ictal events. In children, sedation may be necessary. Image acquisition starts 30 min after injection and ended 15 to 20 min later. Semiquantitative analysis is visually assessed in clinical practice using colour scales. PET sensibility is improved by superimposition of metabolic imaging on MRI. Statistical analysis with S.P.M. may be useful but comparison with health subjects database is required. In medial temporal lobe epilepsy associated with hippocampal sclerosis, hypo metabolism ipsilateral to the epileptogenic focus is found in 70 to 90% of the cases and is predictive of surgical outcome. In other types of temporal and extra temporal epilepsy with negative MRI, focal hypo metabolism can be detected, allowing identification of minor gyral abnormalities corresponding to focal cortical dysplasia. In such MRI negative cases, PET findings may improve surgical outcome. (author)

  16. Current evaluation of the clinical utility of fluoromethyl choline-(18F) PET/CT in prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Talbot, Jean-Noel [Hopital Tenon AP-HP, Paris (France); Universite Pierre et Marie Curie, Paris (France); E-mail: jean-noel.talbot@tnn.ap-hop-paris.fr; Chevalme, Yanna-Marina [Agence Francaise de Securite Sanitaire des Produits de Sante (AFSSAPS), St Denis (France)

    2008-12-15

    This short review is dedicated to the current status of the assessment of a new PET radiopharmaceutical, fluoromethylcholine-(18F) or FCH, which is taken-up by prostate cancer tissue, in contrary to fluorodeoxyglucose- (18F) or FDG. It seems that FCH could become 'the FDG of prostate cancer', with the same type of achievements (detection of distant metastases and of occult recurrences, restaging prior to invasive treatments), and the same drawbacks (false negative results in case of small lesions, in particular lymph nodes metastases, and false positive results in case of infection/inflammation, in particular prostatitis). Current evidence is summarised and discussed for each of the potential settings of FCH PET/CT imaging in prostate cancer. The perspectives for granting a marketing authorisation to a FCH preparation are briefly analysed. (author)

  17. Development of underwater camera using high-definition camera

    International Nuclear Information System (INIS)

    Tsuji, Kenji; Watanabe, Masato; Takashima, Masanobu; Kawamura, Shingo; Tanaka, Hiroyuki

    2012-01-01

    In order to reduce the time for core verification or visual inspection of BWR fuels, the underwater camera using a High-Definition camera has been developed. As a result of this development, the underwater camera has 2 lights and 370 x 400 x 328mm dimensions and 20.5kg weight. Using the camera, 6 or so spent-fuel IDs are identified at 1 or 1.5m distance at a time, and 0.3mmφ pin-hole is recognized at 1.5m distance and 20 times zoom-up. Noises caused by radiation less than 15 Gy/h are not affected the images. (author)

  18. Camera System MTF: combining optic with detector

    Science.gov (United States)

    Andersen, Torben B.; Granger, Zachary A.

    2017-08-01

    MTF is one of the most common metrics used to quantify the resolving power of an optical component. Extensive literature is dedicated to describing methods to calculate the Modulation Transfer Function (MTF) for stand-alone optical components such as a camera lens or telescope, and some literature addresses approaches to determine an MTF for combination of an optic with a detector. The formulations pertaining to a combined electro-optical system MTF are mostly based on theory, and assumptions that detector MTF is described only by the pixel pitch which does not account for wavelength dependencies. When working with real hardware, detectors are often characterized by testing MTF at discrete wavelengths. This paper presents a method to simplify the calculation of a polychromatic system MTF when it is permissible to consider the detector MTF to be independent of wavelength.

  19. Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPECT in Coronary Artery Disease

    International Nuclear Information System (INIS)

    Kong, Eun Jung; Cho, Ihn Ho; Chun, Kyung Ah; Won, Kyu Chang; Lee, Hyung Woo; Park, Jeong Sun; Shin, Dong Gu; Kim, Young Jo; Shim, Bong Seop

    2008-01-01

    N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Seventeen patients (male 13 : 63±11 years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/ 89% vs MPS: 65%/ 82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversible by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability

  20. Effect of Attenuation Correction on Regional Quantification Between PET/MR and PET/CT

    DEFF Research Database (Denmark)

    Teuho, Jarmo; Johansson, Jarkko; Linden, Jani

    2016-01-01

    UNLABELLED: A spatial bias in brain PET/MR exists compared with PET/CT, because of MR-based attenuation correction. We performed an evaluation among 4 institutions, 3 PET/MR systems, and 4 PET/CT systems using an anthropomorphic brain phantom, hypothesizing that the spatial bias would be minimized....../MR systems, CTAC was applied as the reference method for attenuation correction. RESULTS: With CTAC, visual and quantitative differences between PET/MR and PET/CT systems were minimized. Intersystem variation between institutions was +3.42% to -3.29% in all VOIs for PET/CT and +2.15% to -4.50% in all VOIs...... for PET/MR. PET/MR systems differed by +2.34% to -2.21%, +2.04% to -2.08%, and -1.77% to -5.37% when compared with a PET/CT system at each institution, and these differences were not significant (P ≥ 0.05). CONCLUSION: Visual and quantitative differences between PET/MR and PET/CT systems can be minimized...

  1. Dedicated bifurcation stents

    Directory of Open Access Journals (Sweden)

    Ajith Ananthakrishna Pillai

    2012-03-01

    Full Text Available Bifurcation percutaneous coronary intervention (PCI is still a difficult call for the interventionist despite advancements in the instrumentation, technical skill and the imaging modalities. With major cardiac events relate to the side-branch (SB compromise, the concept and practice of dedicated bifurcation stents seems exciting. Several designs of such dedicated stents are currently undergoing trials. This novel concept and pristine technology offers new hope notwithstanding the fact that we need to go a long way in widespread acceptance and practice of these gadgets. Some of these designs even though looks enterprising, the mere complex delivering technique and the demanding knowledge of the exact coronary anatomy makes their routine use challenging.

  2. Quantitative PET imaging with the 3T MR-BrainPET

    International Nuclear Information System (INIS)

    Weirich, C.; Scheins, J.; Lohmann, P.; Tellmann, L.; Byars, L.; Michel, C.; Rota Kops, E.; Brenner, D.; Herzog, H.; Shah, N.J.

    2013-01-01

    The new hybrid imaging technology of MR-PET allows for simultaneous acquisition of versatile MRI contrasts and the quantitative metabolic imaging with PET. In order to achieve the quantification of PET images with minimal residual error the application of several corrections is crucial. In this work we present our results on quantification with the 3T MR BrainPET scanner

  3. Brain PET scan

    Science.gov (United States)

    ... results on a PET scan. Blood sugar or insulin levels may affect the test results in people with diabetes . PET scans may be done along with a CT scan. This combination scan is called a PET/CT. Alternative Names Brain positron emission tomography; PET scan - brain References Chernecky ...

  4. Upgrade of the JET gamma-ray cameras

    International Nuclear Information System (INIS)

    Soare, S.; Curuia, M.; Anghel, M.; Constantin, M.; David, E.; Craciunescu, T.; Falie, D.; Pantea, A.; Tiseanu, I.; Kiptily, V.; Prior, P.; Edlington, T.; Griph, S.; Krivchenkov, Y.; Loughlin, M.; Popovichev, S.; Riccardo, V; Syme, B.; Thompson, V.; Lengar, I.; Murari, A.; Bonheure, G.; Le Guern, F.

    2007-01-01

    Full text: The JET gamma-ray camera diagnostics have already provided valuable information on the gamma-ray imaging of fast ion in JET plasmas. The applicability of gamma-ray imaging to high performance deuterium and deuterium-tritium JET discharges is strongly dependent on the fulfilment of rather strict requirements for the characterisation of the neutron and gamma-ray radiation fields. These requirements have to be satisfied within very stringent boundary conditions for the design, such as the requirement of minimum impact on the co-existing neutron camera diagnostics. The JET Gamma-Ray Cameras (GRC) upgrade project deals with these issues with particular emphasis on the design of appropriate neutron/gamma-ray filters ('neutron attenuators'). Several design versions have been developed and evaluated for the JET GRC neutron attenuators at the conceptual design level. The main design parameter was the neutron attenuation factor. The two design solutions, that have been finally chosen and developed at the level of scheme design, consist of: a) one quasi-crescent shaped neutron attenuator (for the horizontal camera) and b) two quasi-trapezoid shaped neutron attenuators (for the vertical one). The second design solution has different attenuation lengths: a short version, to be used together with the horizontal attenuator for deuterium discharges, and a long version to be used for high performance deuterium and DT discharges. Various neutron-attenuating materials have been considered (lithium hydride with natural isotopic composition and 6 Li enriched, light and heavy water, polyethylene). Pure light water was finally chosen as the attenuating material for the JET gamma-ray cameras. The neutron attenuators will be steered in and out of the detector line-of-sight by means of an electro-pneumatic steering and control system. The MCNP code was used for neutron and gamma ray transport in order to evaluate the effect of the neutron attenuators on the neutron field of the

  5. Clinical PET application

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Moo; Hong, Song W.; Choi, Chang W.; Yang, Seong Dae [Korea Cancer Center Hospital, Seoul (Korea)

    1997-12-01

    PET gives various methabolic images, and is very important, new diagnostic modality in clinical oncology. In Korea Cancer Center Hospital, PET is installed as a research tool of long-mid-term atomic research project. For the efficient use of PET for clinical and research projects, income from the patients should be managed to get the raw material, equipment, manpower, and also for the clinical PET research. 1. Support the clinical application of PET in oncology. 2. Budgetary management of income, costs for raw material, equipment, manpower, and the clinical PET research project. In this year, 250 cases of PET images were obtained, which resulted total income of 180,000,000 won. 50,000,000 won was deposited for the 1998 PET clinical research. Second year PET clinical research should be managed under unified project. Increased demand for {sup 18}FDG in and outside KCCH need more than 2 times production of {sup 18}FDG in a day purchase of HPLC pump and {sup 68}Ga pin source which was delayed due to economic crisis, should be done early in 1998. (author). 2 figs., 3 tabs.

  6. Sub-Camera Calibration of a Penta-Camera

    Science.gov (United States)

    Jacobsen, K.; Gerke, M.

    2016-03-01

    Penta cameras consisting of a nadir and four inclined cameras are becoming more and more popular, having the advantage of imaging also facades in built up areas from four directions. Such system cameras require a boresight calibration of the geometric relation of the cameras to each other, but also a calibration of the sub-cameras. Based on data sets of the ISPRS/EuroSDR benchmark for multi platform photogrammetry the inner orientation of the used IGI Penta DigiCAM has been analyzed. The required image coordinates of the blocks Dortmund and Zeche Zollern have been determined by Pix4Dmapper and have been independently adjusted and analyzed by program system BLUH. With 4.1 million image points in 314 images respectively 3.9 million image points in 248 images a dense matching was provided by Pix4Dmapper. With up to 19 respectively 29 images per object point the images are well connected, nevertheless the high number of images per object point are concentrated to the block centres while the inclined images outside the block centre are satisfying but not very strongly connected. This leads to very high values for the Student test (T-test) of the finally used additional parameters or in other words, additional parameters are highly significant. The estimated radial symmetric distortion of the nadir sub-camera corresponds to the laboratory calibration of IGI, but there are still radial symmetric distortions also for the inclined cameras with a size exceeding 5μm even if mentioned as negligible based on the laboratory calibration. Radial and tangential effects of the image corners are limited but still available. Remarkable angular affine systematic image errors can be seen especially in the block Zeche Zollern. Such deformations are unusual for digital matrix cameras, but it can be caused by the correlation between inner and exterior orientation if only parallel flight lines are used. With exception of the angular affinity the systematic image errors for corresponding

  7. 47 CFR 69.125 - Dedicated signalling transport.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Dedicated signalling transport. 69.125 Section... (CONTINUED) ACCESS CHARGES Computation of Charges § 69.125 Dedicated signalling transport. (a) Dedicated signalling transport shall consist of two elements, a signalling link charge and a signalling transfer point...

  8. Relative camera localisation in non-overlapping camera networks using multiple trajectories

    NARCIS (Netherlands)

    John, V.; Englebienne, G.; Kröse, B.J.A.

    2012-01-01

    In this article we present an automatic camera calibration algorithm using multiple trajectories in a multiple camera network with non-overlapping field-of-views (FOV). Visible trajectories within a camera FOV are assumed to be measured with respect to the camera local co-ordinate system.

  9. Quantitative assessment of regional myocardial flow reserve using Tc-99m-sestamibi imaging. Comparison with results of O-15 water PET

    International Nuclear Information System (INIS)

    Tsukamoto, Takahiro; Ito, Yoshinori; Noriyasu, Kazuyuki; Morita, Koichi; Katoh, Chietsugu; Okamoto, Hiroshi; Tamaki, Nagara

    2005-01-01

    The aims of this study were to develop a method for quantitative estimation of the myocardial blood flow index (MBFI) and myocardial flow reserve (MFR) of the whole left ventricle using 99m technetium (Tc-99m)-sestamibi imaging. Twenty-two patients with suspected coronary artery disease and 7 controls underwent both Tc-99m-sestamibi imaging and O-15 water positron emission tomography (PET). The global MBFI was calculated on the basis of the microsphere model from the ratio of the myocardial count to the area under the time-activity curve on the aortic arch. The regional MBFI was calculated from the relative distributions of Tc-99m-sestamibi uptake values. The regional MBFI and MFR (Tc-MFR) obtained using single-photon emission computed tomography were compared with the myocardial blood flow (MBF) and MFR (PET-MFR) obtained using PET as the gold standard. Regional MBFI significantly correlated with the MBF obtained using PET. Regional Tc-MFR also correlated with the regional PET-MER, with some underestimation. These results indicate that regional MBF and MFR may be estimated by dynamic Tc-99m-sestamibi imaging and can be used for the early detection and estimation of the functional severity of coronary lesions without the need for a PET camera. (author)

  10. PET and PET/CT in oncology: the key of diagnostic challenge

    International Nuclear Information System (INIS)

    Mortelmans, L.; Stroobants, S.; Spaepen, K.

    2004-01-01

    In this presentation authors present use of positron emission tomography (PET) in oncology. This lecture is divided to the following parts: (1) Assessment of treatment response; (2) Treatment monitoring by PET: clinical examples; (3) PET for early response assessment; (4) Use of PET in Radiotherapy planning

  11. A prospective multi-centre study of the value of FDG-PET as part of a structured diagnostic protocol in patients with fever of unknown origin

    International Nuclear Information System (INIS)

    Bleeker-Rovers, Chantal P.; Vos, Fidel J.; Meer, Jos W.M. van der; Mudde, Aart H.; Dofferhoff, Anton S.M.; Geus-Oei, Lioe-Fee de; Rijnders, Anton J.; Krabbe, Paul F.M.; Corstens, Frans H.M.; Oyen, Wim J.G.

    2007-01-01

    Since 18 F-fluorodeoxyglucose (FDG) accumulates in neoplastic cells and in activated inflammatory cells, positron emission tomography (PET) with FDG could be valuable in diagnosing patients with fever of unknown origin (FUO). The aim of this study was to validate the use of FDG-PET as part of a structured diagnostic protocol in the general patient population with FUO. From December 2003 to July 2005, 70 patients with FUO were recruited from one university hospital (n=38) and five community hospitals (n=32). A structured diagnostic protocol including FDG-PET was used. A dedicated, full-ring PET scanner was used for data acquisition. FDG-PET scans were interpreted by two staff members of the department of nuclear medicine without further clinical information. The final clinical diagnosis was used for comparison with the FDG-PET results. Of all scans, 33% were clinically helpful. The contribution of FDG-PET to the final diagnosis did not differ significantly between patients diagnosed in the university hospital and patients diagnosed in the community hospitals. FDG-PET contributed significantly more often to the final diagnosis in patients with continuous fever than in patients with periodic fever. FDG-PET was not helpful in any of the patients with normal erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP). FDG-PET is a valuable imaging technique as part of a diagnostic protocol in the general patient population with FUO and a raised ESR or CRP. (orig.)

  12. Various dedicated imaging systems for routine nuclear medical applications

    International Nuclear Information System (INIS)

    Bela Kari; Tamas Gyorke; Erno Mako; Laszlo Nagy; Jozsef Turak; Oszkar Partos

    2004-01-01

    The most essential problems of nuclear medical imaging are resolution, signal/noise ratio (S/N) and sensitivity. Nowadays, the vast majority of the Anger system gamma cameras in clinical application are using parallel projection. The main problem of this projection method is the highly dependence of the image quality on the distance from the collimator surface as well as any improvement in the resolution with the distance -i.e. reduction of image blur- significantly reduces sensitivity. The aim of our research and development work was to create imaging geometry, collimator and detector constructions optimized to particular organs (brain, heart, thyroid), where it is simultaneously possible to increase the resolution and sensitivity. Main concept of the imaging geometry construction is based on the size, location and shape of a particular organ. In case of brain SPECT imaging a multiple head (4 heads in cylinder symmetric approximation) arrangement with extra high intrinsic resolution (<2.5 mm) dedicated detector design provide feasible solution for routine clinical application. The imaging system was essentially designed for Tc-99m and I-123 isotopes. The application field can be easily extended for functional small animal research and new born baby studies. Very positive feedbacks were received from both technical (stability and reproducibility of the technical parameters) and clinical sides in the past 2 years routine applications. A unique, novel conception ultra compact dedicated dual head SPECT system has been created only for 2D, 3D nuclear cardiac applications for Tc-99m and T1-201 labeled radio-pharmaceuticals. The two rectangular detectors (with <2.6 mm intrinsic resolution) are mounted fix in 90 degree geometry and move inside the special formed gantry arrangement. The unique and unusual gantry is designed to keep the detector heads as close as possible to the patient, while the patient is not exposed by any moving part. This special construction also

  13. The Rutherford Appleton Laboratory's Mark I Multiwire Proportional Counter positron camera

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Tappern, G.J.; Flesher, A.C.

    1983-01-01

    A small model of a proposed large aperture positron camera has been developed at Rutherford Appleton Laboratory. Based on Multiwire Proportional Counter technology it uses lead foil cathodes which function simultaneously as converters for the 511 keV gamma rays and readout electrodes for a delay line readout system. The detectors have been built up into a portable imaging system complete with a dedicated computer for data taking, processing and display. A complete hardware system and sufficient software was provided to permit hospital based colleagues to generate useful images easily. A complete description of the system is given with performance figures and some of the images obtained are presented. (author)

  14. The effect of 18F-FDG-PET image reconstruction algorithms on the expression of characteristic metabolic brain network in Parkinson's disease.

    Science.gov (United States)

    Tomše, Petra; Jensterle, Luka; Rep, Sebastijan; Grmek, Marko; Zaletel, Katja; Eidelberg, David; Dhawan, Vijay; Ma, Yilong; Trošt, Maja

    2017-09-01

    To evaluate the reproducibility of the expression of Parkinson's Disease Related Pattern (PDRP) across multiple sets of 18F-FDG-PET brain images reconstructed with different reconstruction algorithms. 18F-FDG-PET brain imaging was performed in two independent cohorts of Parkinson's disease (PD) patients and normal controls (NC). Slovenian cohort (20 PD patients, 20 NC) was scanned with Siemens Biograph mCT camera and reconstructed using FBP, FBP+TOF, OSEM, OSEM+TOF, OSEM+PSF and OSEM+PSF+TOF. American Cohort (20 PD patients, 7 NC) was scanned with GE Advance camera and reconstructed using 3DRP, FORE-FBP and FORE-Iterative. Expressions of two previously-validated PDRP patterns (PDRP-Slovenia and PDRP-USA) were calculated. We compared the ability of PDRP to discriminate PD patients from NC, differences and correlation between the corresponding subject scores and ROC analysis results across the different reconstruction algorithms. The expression of PDRP-Slovenia and PDRP-USA networks was significantly elevated in PD patients compared to NC (palgorithms. PDRP expression strongly correlated between all studied algorithms and the reference algorithm (r⩾0.993, palgorithms varied within 0.73 and 0.08 of the reference value for PDRP-Slovenia and PDRP-USA, respectively. ROC analysis confirmed high similarity in sensitivity, specificity and AUC among all studied reconstruction algorithms. These results show that the expression of PDRP is reproducible across a variety of reconstruction algorithms of 18F-FDG-PET brain images. PDRP is capable of providing a robust metabolic biomarker of PD for multicenter 18F-FDG-PET images acquired in the context of differential diagnosis or clinical trials. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. Comparison of dosimetry between PET/CT and PET alone using 11C-ITMM

    International Nuclear Information System (INIS)

    Ito, Kimiteru; Sakata, Muneyuki; Wagarsuma, Kei; Toyohara, Jun; Ishibashi, Kenji; Ishii, Kenji; Ishiwata, Kiichi; Oda, Keiichi

    2016-01-01

    We used a new tracer, N-[4-[6-(isopropylamino) pyrimidin-4-yl]-1,3-thiazol-2-yl]-4- 11 C-methoxy-N-methylbenzamide ( 11 C-ITMM), to compare radiation doses from positron emission tomography (PET)/computed tomography (CT) with previously published doses from PET alone. Twelve healthy volunteers [six males (mean age ± SD, 27.7 ± 6.7 years) and six females (31.8 ± 14.5 years)] in 12 examinations were recruited. Dose estimations from PET/CT were compared with those from PET alone. Regions of interest (ROIs) in PET/CT were delineated on the basis of low-dose CT (LD-CT) images acquired during PET/CT. Internal and external radiation doses were estimated using OLINDA/EXM 1.0 and CT-Expo software. The effective dose (ED) for 11 C-ITMM calculated from PET/CT was estimated to be 4.7 ± 0.5 μSv/MBq for the male subjects and 4.1 ± 0.7 μSv/MBq for the female subjects. The mean ED for 11 C-ITMM calculated from PET alone in a previous report was estimated to be 4.6 ± 0.3 μSv/MBq (males, n = 3). The ED values for 11 C-ITMM calculated from PET/CT in the male subjects were almost identical to those from PET alone. The absorbed doses (ADs) of the gallbladder, stomach, red bone marrow, and spleen calculated from PET/CT were significantly different from those calculated from PET alone. The EDs of 11 C-ITMM calculated from PET/CT were almost identical to those calculated from PET alone. The ADs in several organs calculated from PET/CT differed from those from PET alone. LD-CT images acquired during PET/CT may facilitate organ identification.

  16. A pixellated gamma-camera based on CdTe detectors clinical interests and performances

    CERN Document Server

    Chambron, J; Eclancher, B; Scheiber, C; Siffert, P; Hage-Ali, M; Regal, R; Kazandjian, A; Prat, V; Thomas, S; Warren, S; Matz, R; Jahnke, A; Karman, M; Pszota, A; Németh, L

    2000-01-01

    A mobile gamma camera dedicated to nuclear cardiology, based on a 15 cmx15 cm detection matrix of 2304 CdTe detector elements, 2.83 mmx2.83 mmx2 mm, has been developed with a European Community support to academic and industrial research centres. The intrinsic properties of the semiconductor crystals - low-ionisation energy, high-energy resolution, high attenuation coefficient - are potentially attractive to improve the gamma-camera performances. But their use as gamma detectors for medical imaging at high resolution requires production of high-grade materials and large quantities of sophisticated read-out electronics. The decision was taken to use CdTe rather than CdZnTe, because the manufacturer (Eurorad, France) has a large experience for producing high-grade materials, with a good homogeneity and stability and whose transport properties, characterised by the mobility-lifetime product, are at least 5 times greater than that of CdZnTe. The detector matrix is divided in 9 square units, each unit is composed ...

  17. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  18. Pet-Related Infections.

    Science.gov (United States)

    Day, Michael J

    2016-11-15

    Physicians and veterinarians have many opportunities to partner in promoting the well-being of people and their pets, especially by addressing zoonotic diseases that may be transmitted between a pet and a human family member. Common cutaneous pet-acquired zoonoses are dermatophytosis (ringworm) and sarcoptic mange (scabies), which are both readily treated. Toxoplasmosis can be acquired from exposure to cat feces, but appropriate hygienic measures can minimize the risk to pregnant women. Persons who work with animals are at increased risk of acquiring bartonellosis (e.g., cat-scratch disease); control of cat fleas is essential to minimize the risk of these infections. People and their pets share a range of tick-borne diseases, and exposure risk can be minimized with use of tick repellent, prompt tick removal, and appropriate tick control measures for pets. Pets such as reptiles, amphibians, and backyard poultry pose a risk of transmitting Salmonella species and are becoming more popular. Personal hygiene after interacting with these pets is crucial to prevent Salmonella infections. Leptospirosis is more often acquired from wildlife than infected dogs, but at-risk dogs can be protected with vaccination. The clinical history in the primary care office should routinely include questions about pets and occupational or other exposure to pet animals. Control and prevention of zoonoses are best achieved by enhancing communication between physicians and veterinarians to ensure patients know the risks of and how to prevent zoonoses in themselves, their pets, and other people.

  19. Simulation of a MR–PET protocol for staging of head-and-neck cancer including Dixon MR for attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Eiber, Matthias, E-mail: matthias.eiber@tum.de [Department of Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); Souvatzoglou, Michael, E-mail: msouvatz@yahoo.de [Department of Nuclear Medicine, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); Pickhard, Anja, E-mail: a.pickhard@lrz.tum.de [Department of Otorhinolaryngology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); Loeffelbein, Denys J., E-mail: denys.loeffelbein@gmx.de [Department of Maxillofacial Surgery, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); Knopf, Andreas, E-mail: andreas.knopf@tum.de [Department of Otorhinolaryngology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); Holzapfel, Konstantin, E-mail: holzapfel@roe.med.tum.de [Department of Radiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); Martinez-Möller, Axel, E-mail: a.martinez-moller@lrz.tu-muenchen.de [Department of Nuclear Medicine, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675 Munich (Germany); and others

    2012-10-15

    Purpose: To simulate and optimize a MR protocol for squamous cell cancer of the head and neck (HNSCC) patients for potential future use in an integrated whole-body MR–PET scanner. Materials and methods: On a clinical 3T scanner, which is the basis for a recently introduced fully integrated whole-body MR–PET, 20 patients with untreated HNSCC routinely staged with 18F-FDG PET/CT underwent a dedicated MR protocol for the neck. Moreover, a whole-body Dixon MR-sequence was applied, which is used for attenuation correction on a recently introduced hybrid MR–PET scanner. In a subset of patients volume-interpolated-breathhold (VIBE) T1w-sequences for lungs and liver were added. Total imaging time was analyzed for both groups. The quality of the delineation of the primary tumor (scale 0–3) and the presence or absence of lymph node metastases (scale 1–5) was evaluated for CT, MR, PET/CT and a combination of MR and PET to ensure that the MR–PET fusion does not cause a loss of diagnostic capability. PET was used to identify distant metastases. The PET dataset for simulated MR/PET was based on a segmentation of the CT data into 4 classes according to the approach of the Dixon MR-sequence for MR–PET. Standard of reference was histopathology in 19 cases. In one case no histopathological confirmation of a primary tumor could be achieved. Results: Mean imaging time was 35:17 min (range: 31:08–42:42 min) for the protocol including sequences for local staging and attenuation correction and 44:17 min (range: 35:44–54:58) for the extended protocol. Although not statistically significant a combination of MR and PET performed better in the delineation of the primary tumor (mean 2.20) compared to CT (mean 1.40), MR (1.95) and PET/CT (2.15) especially in patients with dental implants. PET/CT and combining MR and PET performed slightly better than CT and MR for the assessment of lymph node metastases. Two patients with distant metastases were only identified by PET

  20. PET and PET-CT. State of the art and future prospects

    International Nuclear Information System (INIS)

    Fanti, Stefano; Franchi, Roberto; Battista, Giuseppe; Monetti, Nino; Canini, Romeo

    2005-01-01

    Fluoro-deoxyglucose positron emission tomography (FDG PET) enables the in vivo study of tissue metabolism, and thus is able to identify malignant tumours as hypermetabolic lesions by an increase in tracer uptake. Many papers have demonstrated both the relevant impact of FDG PET on staging of many cancers and the superior accuracy of the technique compared with conventional diagnostic methods for pre-treatment evaluation, therapy response evaluation and relapse identification. In particular PET was found useful in identifying lymph nodal and metastatic spread. thus altering patient management in more than 30% of cases. PET images, however, provide limited anatomical data, which in regions such as the head and neck, mediastinum and pelvic cavity is a significant drawback. The exact localization of lesions may also be difficult in some cases, on the basis of PET images alone. The introduction of combined PET-computed tomography (PET-CT) scanners enables the almost simultaneous acquisition of transmission and emission images, thus obtaining optimal fusion images in a very short time. PET-CT fusion images enable lesions to be located, reducing false positive studies and increasing accuracy; the overall duration of examination may also be reduced. On the basis of both literature data and our experience we established the clinical indications when PET-CT may be particularly useful, in comparison with PET alone. It should also be underlined that the use of PET-CT is almost mandatory for new traces such as C-choline and C-methionine; these new tracers may be applied for studying tumours not assessable with FDG, such as prostate cancer. In conclusion PET-CT is at present the most advanced method for metabolic imaging, and is capable of precisely localizing and assessing tumours; fusion images reduce false positive and inconclusive studies, thus increasing diagnostic accuracy [it

  1. Development of PET insert for simultaneous PET/MR imaging of human brain

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jiwoong; Choi, Yong; Jung, Jin Ho; Kim, Sangsu; Im, Ki Chun; Lim, Hyun Keong [Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul (Korea, Republic of); Oh, Changheun; Park, HyunWook; Cho, Gyuseong [Departments of Electrical Engineering and Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon (Korea, Republic of)

    2014-07-29

    Recently, there has been great interest on the development of combined PET/MR, which is a useful tool for both functional and anatomic imaging. The purpose of this study was to develop a MR compatible PET insert for simultaneous PET and MR imaging of human brain and to evaluate the performance of the hybrid PET-MRI. The PET insert consisted of 18 detector blocks arranged in a ring of 390 mm diameter with 60 mm axial FOV. Each detector block was composed of 4 × 4 matrix of detector modules, each of which consisted of a 4 × 4 array LYSO coupled to a 4 × 4 GAPD array. The PET gantry was shielded with gold-plated conductive fabric tapes. The charge signals of PET detector transferred via 4 m long flat cables were fed into the position decoder circuits (PDCs) and then transferred to FPGA-embedded DAQ modules. The PDCs and DAQ modules were enclosed in an aluminum box and located at the rear of the MR bore inside MRI room. 3-T human MRIs of two different vendors were used to evaluate the MR compatibility of developed PET insert. No significant changes of the PET performance and the homogeneity of MR images caused by the non-compatibility of PET-MRI were observed with the 2 different MRIs. The signal intensities of MR images were slightly degraded (<3.6%) with the both MRI systems. The difference between independently and simultaneously acquired PET images of brain phantom was negligibly small (<4.3%). High quality simultaneous brain PET and MRI of 3 normal volunteers were successfully acquired. Experimental results indicate that the high performance compact and lightweight PET insert for hybrid PET/MRI, which could be utilized with the MRI from various manufactures, can be developed using GAPD arrays and charge signal transmission method proposed in this study.

  2. Physics and instrumentation of emission computed tomography

    International Nuclear Information System (INIS)

    Links, J.M.

    1986-01-01

    Transverse emission computed tomography can be divided into two distinct classes: single photon emission computed tomography (SPECT) and positron emission tomography (PET). SPECT is usually accomplished with specially-adapted scintillation cameras, although dedicated SPECT scanners are available. The special SPECT cameras are standard cameras which are mounted on gantries that allow 360 degree rotation around the long axis of the head or body. The camera stops at a number of angles around the body (usually 64-128), acquiring a ''projection'' image at each stop. The data from these projections are used to reconstruct transverse images with a standard ''filtered back-projection'' algorithm, identical to that used in transmission CT. Because the scintillation camera acquires two-dimensional images, a simple 360 degree rotation around the patient results in the acquisition of data for a number of contiguous transverse slices. These slices, once reconstructed, can be ''stacked'' in computer memory, and orthogonal coronal and sagittal slices produced. Additionally, reorienting algorithms allow the generation of slices that are oblique to the long axis of the body

  3. PET/MRI and PET/CT in advanced gynaecological tumours: initial experience and comparison

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Marcelo A.; Schulthess, Gustav von; Veit-Haibach, Patrick [University Hospital Zurich, Department Medical Radiology, Nuclear Medicine, Zurich (Switzerland); University Hospital Zurich, Department Medical Radiology, Diagnostic and Interventional Radiology, Zurich (Switzerland); University of Zurich, Zurich (Switzerland); Kubik-Huch, Rahel A.; Freiwald-Chilla, Bianka [Kantonsspital Baden AG, Department of Radiology, Baden (Switzerland); Hauser, Nik [Kantonsspital Baden AG, Department of Gynaecology, Baden (Switzerland); Froehlich, Johannes M. [Guerbet AG, Zurich (Switzerland)

    2015-08-15

    To compare the diagnostic accuracy of PET/MRI and PET/CT for staging and re-staging advanced gynaecological cancer patients as well as identify the potential benefits of each method in such a population. Twenty-six patients with suspicious or proven advanced gynaecological cancer (12 ovarian, seven cervical, one vulvar and four endometrial tumours, one uterine metastasis, and one primary peritoneal cancer) underwent whole-body imaging with a sequential trimodality PET/CT/MR system. Images were analysed regarding primary tumour detection and delineation, loco-regional lymph node staging, and abdominal/extra-abdominal distant metastasis detection (last only by PET/CT). Eighteen (69.2 %) patients underwent PET/MRI for primary staging and eight patients (30.8 %) for re-staging their gynaecological malignancies. For primary tumour delineation, PET/MRI accuracy was statistically superior to PET/CT (p < 0.001). Among the different types of cancer, PET/MRI presented better tumour delineation mainly for cervical (6/7) and endometrial (2/3) cancers. PET/MRI for local evaluation as well as PET/CT for extra-abdominal metastases had therapeutic consequences in three and one patients, respectively. PET/CT detected 12 extra-abdominal distant metastases in 26 patients. PET/MRI is superior to PET/CT for primary tumour delineation. No differences were found in detection of regional lymph node involvement and abdominal metastases detection. (orig.)

  4. Comparative analysis of PET/CT and PET/MR image characteristics of head and neck squamous cell carcinoma%对比分析头颈部鳞状细胞癌PET/CT与PET/MR特征

    Institute of Scientific and Technical Information of China (English)

    白乐; 程勇; 唐勇进; 凌雪英

    2017-01-01

    Objective To investigate PET/CT and PET/MR characteristics of head and neck squamous cell carcinoma (HNSCC).Methods Totally 40 patients with HNSCC underwent whole body 18F-FDG PET/CT and MR scans of head and neck before anti-tumor treatment.PET positive lesions of HNSCC,including primary lesions and lymph nodes were evaluated by 2 radiologists independently.Then the imaging quality,fusion quality,lesion conspicuity and lesion characteristics were assessed based on PET/CT,PET/MR T1WI and PET/MR T2WI.Results Ninety PET positive lesions in all 40patients were evaluated,including 40 primary lesions and 50 lymph nodes.Similar imaging quality and fusion quality of PET/CT,PET/MR T1WI and PET/MR T2WI were obtained without statistical difference (both P>0.05).For the lesion conspicuity,PET/MR T1WI and PET/MR T2WI demonstrated significantly better than PET/CT in positive primary lesions and lymph nodes (all P<0.05).For the characteristics of positive primary lesions,PET/MR T2WI provided more information than PET/CT in 29 lesions,equal to PET/CT in 4 lesions,and less than PET/CT in 7 lesions.Conclusion The application of PET/MR in HNSCC is feasible,being superior to PET/CT in indication of lesions in head and neck area.%目的 探讨头颈部鳞状细胞癌(HNSCC)的PET/CT及PET/MR特征.方法 纳入未经抗肿瘤治疗的头颈部鳞状细胞癌患者40例,所有患者均接受PET/CT及头颈部MR检查.由2名观察者独立观察PET阳性病灶,包括阳性原发灶及阳性淋巴结;并对PET/CT、PET/MR T1WI及PET/MR T2WI的图像质量、融合准确度、病灶清晰度、病灶特征等进行评分.分析2名观察者间的一致性.结果 40例患者共90个PET阳性病灶,包括阳性原发灶40个、阳性淋巴结50个.PET/CT、PET/MR T1WI及PET/MR T2WI在图像质量及融合准确度方面差异均无统计学意义(P均>0.05);在显示阳性原发灶及阳性淋巴结的清晰度方面,PET/MR T1WI及PET/MR T2WI均优于PET/CT(P均<0.05).40个阳性原发灶中,PET

  5. Present and future of PET and PET/CT in gynaecologic malignancies

    International Nuclear Information System (INIS)

    Musto, Alessandra; Rampin, Lucia; Nanni, Cristina; Marzola, Maria Cristina; Fanti, Stefano; Rubello, Domenico

    2011-01-01

    Objectives: To review the published data in literature on patients affected by gynaecological malignancies to establish the role of 18 F-FDG positron emission tomography (PET) and PET/CT in comparison to conventional imaging (CI). Materials and methods: All papers specifically addressed to the role of 18 F-FDG PET and PET/CT in gynaecological malignancies published on PubMed/Medline, in abstracts from the principal international congresses, in the guidelines from national Societies that had appeared in literature until November 2009 were considered for the purpose of the present study. Results and conclusions: The use of 18 F-FDG PET, and even more of 18 F-FDG PET/CT, is increasing in the follow up of patients with gynaecologic malignancies and suspected recurrent disease: there is evidence in the literature that 18 F-FDG PET/CT has a higher sensitivity than CI in depicting occult metastatic spread. An interesting issue is represented by patients with ovarian cancer with an increase of the specific biomarker, CA-125, and negative/inconclusive findings at CI. The use of 18 F-FDG PET in differential diagnosis and staging is more controversial, but there is some evidence that a baseline PET examination performed before commencing therapy, for staging purpose, is also useful to evaluate the response to chemoradiation treatment. In several papers it has been suggested a relevant role of 18 F-FDG PET/CT in evaluating the entity of response to treatment and therefore to plan the subsequent therapeutic strategy.

  6. Role of FDG-PET scans in staging, response assessment, and follow-up care for non-small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Cuaron, John [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Dunphy, Mark [Department of Nuclear Medicine, Memorial Sloan-Kettering Cancer Center, New York, NY (United States); Rimner, Andreas, E-mail: rimnera@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2013-01-03

    The integral role of positron-emission tomography (PET) using the glucose analog tracer fluorine-18 fluorodeoxyglucose (FDG) in the staging of non-small cell lung cancer (NSCLC) is well established. Evidence is emerging for the role of PET in response assessment to neoadjuvant therapy, combined-modality therapy, and early detection of recurrence. Here, we review the current literature on these aspects of PET in the management of NSCLC. FDG-PET, particularly integrated {sup 18}F-FDG-PET/CT, scans have become a standard test in the staging of local tumor extent, mediastinal lymph node involvement, and distant metastatic disease in NSCLC. {sup 18}F-FDG-PET sensitivity is generally superior to computed tomography (CT) scans alone. Local tumor extent and T stage can be more accurately determined with FDG-PET in certain cases, especially in areas of post-obstructive atelectasis or low CT density variation. FDG-PET sensitivity is decreased in tumors <1 cm, at least in part due to respiratory motion. False-negative results can occur in areas of low tumor burden, e.g., small lymph nodes or ground-glass opacities. {sup 18}F-FDG-PET-CT nodal staging is more accurate than CT alone, as hilar and mediastinal involvement is often detected first on {sup 18}F-FDG-PET scan when CT criteria for malignant involvement are not met. {sup 18}F-FDG-PET scans have widely replaced bone scintography for assessing distant metastases, except for the brain, which still warrants dedicated brain imaging. {sup 18}F-FDG uptake has also been shown to vary between histologies, with adenocarcinomas generally being less FDG avid than squamous cell carcinomas. {sup 18}F-FDG-PET scans are useful to detect recurrences, but are currently not recommended for routine follow-up. Typically, patients are followed with chest CT scans every 3–6 months, using {sup 18}F-FDG-PET to evaluate equivocal CT findings. As high {sup 18}F-FDG uptake can occur in infectious, inflammatory, and other non-neoplastic conditions

  7. Molecular Targets for PET Imaging of Activated Microglia: The Current Situation and Future Expectations.

    Science.gov (United States)

    Tronel, Claire; Largeau, Bérenger; Santiago Ribeiro, Maria Joao; Guilloteau, Denis; Dupont, Anne-Claire; Arlicot, Nicolas

    2017-04-11

    Microglia, as cellular mediators of neuroinflammation, are implicated in the pathogenesis of a wide range of neurodegenerative diseases. Positron emission tomography (PET) imaging of microglia has matured over the last 20 years, through the development of radiopharmaceuticals targeting several molecular biomarkers of microglial activation and, among these, mainly the translocator protein-18 kDa (TSPO). Nevertheless, current limitations of TSPO as a PET microglial biomarker exist, such as low brain density, even in a neurodegenerative setting, expression by other cells than the microglia (astrocytes, peripheral macrophages in the case of blood brain barrier breakdown), genetic polymorphism, inducing a variation for most of TSPO PET radiopharmaceuticals' binding affinity, or similar expression in activated microglia regardless of its polarization (pro- or anti-inflammatory state), and these limitations narrow its potential interest. We overview alternative molecular targets, for which dedicated radiopharmaceuticals have been proposed, including receptors (purinergic receptors P2X7, cannabinoid receptors, α7 and α4β2 nicotinic acetylcholine receptors, adenosine 2A receptor, folate receptor β) and enzymes (cyclooxygenase, nitric oxide synthase, matrix metalloproteinase, β-glucuronidase, and enzymes of the kynurenine pathway), with a particular focus on their respective contribution for the understanding of microglial involvement in neurodegenerative diseases. We discuss opportunities for these potential molecular targets for PET imaging regarding their selectivity for microglia expression and polarization, in relation to the mechanisms by which microglia actively participate in both toxic and neuroprotective actions in brain diseases, and then take into account current clinicians' expectations.

  8. Mobile phone camera benchmarking: combination of camera speed and image quality

    Science.gov (United States)

    Peltoketo, Veli-Tapani

    2014-01-01

    When a mobile phone camera is tested and benchmarked, the significance of quality metrics is widely acknowledged. There are also existing methods to evaluate the camera speed. For example, ISO 15781 defines several measurements to evaluate various camera system delays. However, the speed or rapidity metrics of the mobile phone's camera system have not been used with the quality metrics even if the camera speed has become more and more important camera performance feature. There are several tasks in this work. Firstly, the most important image quality metrics are collected from the standards and papers. Secondly, the speed related metrics of a mobile phone's camera system are collected from the standards and papers and also novel speed metrics are identified. Thirdly, combinations of the quality and speed metrics are validated using mobile phones in the market. The measurements are done towards application programming interface of different operating system. Finally, the results are evaluated and conclusions are made. The result of this work gives detailed benchmarking results of mobile phone camera systems in the market. The paper defines also a proposal of combined benchmarking metrics, which includes both quality and speed parameters.

  9. Performance of the prototype LaBr{sub 3} spectrometer developed for the JET gamma-ray camera upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Rigamonti, D., E-mail: davide.rigamonti@mib.infn.it; Nocente, M.; Gorini, G. [Dipartimento di Fisica “G. Occhialini,” Università degli Studi di Milano-Bicocca, Milano (Italy); Istituto di Fisica del Plasma “P. Caldirola,” CNR, Milano (Italy); Muraro, A.; Giacomelli, L.; Cippo, E. P.; Tardocchi, M. [Istituto di Fisica del Plasma “P. Caldirola,” CNR, Milano (Italy); Perseo, V. [Dipartimento di Fisica “G. Occhialini,” Università degli Studi di Milano-Bicocca, Milano (Italy); Boltruczyk, G.; Gosk, M.; Korolczuk, S.; Mianowski, S.; Zychor, I. [Narodowe Centrum Badań Jądrowych (NCBJ), 05-400 Otwock-Swierk (Poland); Fernandes, A.; Pereira, R. C. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Lisboa (Portugal); Figueiredo, J. [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Lisboa (Portugal); EUROfusion Programme Management Unit, Culham Science Centre, OX14 3DB Abingdon (United Kingdom); Kiptily, V. [Culham Science Centre for Fusion Energy, Culham (United Kingdom); Murari, A. [EUROfusion Programme Management Unit, Culham Science Centre, OX14 3DB Abingdon (United Kingdom); Consorzio RFX (CNR, ENEA, INFN, Universita’ di Padova, Acciaierie Venete SpA), Padova (Italy); Collaboration: EUROfusion Consortium, JET, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)

    2016-11-15

    In this work, we describe the solution developed by the gamma ray camera upgrade enhancement project to improve the spectroscopic properties of the existing JET γ-ray camera. Aim of the project is to enable gamma-ray spectroscopy in JET deuterium-tritium plasmas. A dedicated pilot spectrometer based on a LaBr{sub 3} crystal coupled to a silicon photo-multiplier has been developed. A proper pole zero cancellation network able to shorten the output signal to a length of 120 ns has been implemented allowing for spectroscopy at MHz count rates. The system has been characterized in the laboratory and shows an energy resolution of 5.5% at E{sub γ} = 0.662 MeV, which extrapolates favorably in the energy range of interest for gamma-ray emission from fast ions in fusion plasmas.

  10. {sup 18}F-FDG PET and PET/CT in Burkitt's lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Karantanis, Dimitrios, E-mail: dkarantanis@nuclmed.ne [Division of Nuclear Medicine, Department of Radiology, Mayo Clinic, Rochester, MN (United States); Durski, Jolanta M.; Lowe, Val J.; Nathan, Mark A.; Mullan, Brian P. [Division of Nuclear Medicine, Department of Radiology, Mayo Clinic, Rochester, MN (United States); Georgiou, Evangelos [Medical Physics Department, Medical School, University of Athens (Greece); Johnston, Patrick B. [Division of Hematology, Department of Medicine, Mayo Clinic, Rochester, MN (United States); Wiseman, Gregory A. [Division of Nuclear Medicine, Department of Radiology, Mayo Clinic, Rochester, MN (United States)

    2010-07-15

    Objective: To explore the value of {sup 18}F fluorodeoxy-glucose (FDG) positron emission tomography (PET) in Burkitt's lymphoma. Methods: All Burkitt's lymphoma patients referred for FDG PET or FDG PET/computed tomography (CT) exams at our institution from June 2003 to June 2006 were included. Selected patients were followed and clinical information was reviewed retrospectively. Results from FDG PET-PET/CT, as blindly reviewed by a consensus of two experienced readers, were compared with the status of the disease as determined by other laboratory, clinical and imaging exams and clinical follow-up. FDG PET-PET/CT results were classified as true positive or negative and false positive or negative. The degree of FDG uptake in the positive lesions was semiquantified as maximum standard uptake value (SUVmax). Results: Fifty-seven FDG PET-PET/CT exams were done in 15 patients. Seven exams were done for initial staging, 8 during and 14 after the completion of therapy, and 28 for disease surveillance. For nodal disease FDG PET-PET/CT was true positive in 8, true negative in 47 and false positive in 2 exams (sensitivity 100%, specificity 96%). For extranodal disease FDG PET-PET/CT was true positive in 6, true negative in 48 and false positive in 3 exams (sensitivity 100%, specificity 94%). The mean SUVmax for the positive nodal lesions was 15.7 (range 6.9-21.7, median 18.5) and for extranodal lesions was 14.2 (range 6.2-24.3, median 12.4). Conclusions: FDG PET-PET/CT is sensitive for the detection of viable disease in Burkitt's lymphoma. Affected areas demonstrated high degree of uptake that was reversible upon successful implementation of treatment.

  11. Standardised uptake values from PET/CT images: comparison with conventional attenuation-corrected PET

    International Nuclear Information System (INIS)

    Souvatzoglou, M.; Ziegler, S.I.; Martinez, M.J.; Dzewas, G.; Schwaiger, M.; Bengel, F.; Busch, R.

    2007-01-01

    In PET/CT, CT-derived attenuation factors may influence standardised uptake values (SUVs) in tumour lesions and organs when compared with stand-alone PET. Therefore, we compared PET/CT-derived SUVs intra-individually in various organs and tumour lesions with stand-alone PET-derived SUVs. Thirty-five patients with known or suspected cancer were prospectively included. Sixteen patients underwent FDG PET using an ECAT HR+scanner, and subsequently a second scan using a Biograph Sensation 16PET/CT scanner. Nineteen patients were scanned in the reverse order. All images were reconstructed with an iterative algorithm (OSEM). Suspected lesions were grouped as paradiaphragmatic versus distant from the diaphragm. Mean and maximum SUVs were also calculated for brain, lung, liver, spleen and vertebral bone. The attenuation coefficients (μ values) used for correction of emission data (bone, soft tissue, lung) in the two data sets were determined. A body phantom containing six hot spheres and one cold cylinder was measured using the same protocol as in patients. Forty-six lesions were identified. There was a significant correlation of maximum and mean SUVs derived from PET and PET/CT for 14 paradiaphragmatic lesions (r=0.97 respectively; p<0.001 respectively) and for 32 lesions located distant from the diaphragm (r=0.87 and r=0.89 respectively; p<0.001 respectively). No significant differences were observed in the SUVs calculated with PET and PET/CT in the lesions or in the organs. In the phantom, radioactivity concentration in spheres calculated from PET and from PET/CT correlated significantly (r=0.99; p<0.001). SUVs of cancer lesions and normal organs were comparable between PET and PET/CT, supporting the usefulness of PET/CT-derived SUVs for quantification of tumour metabolism. (orig.)

  12. Statistical parametric maps of 18F-FDG PET and 3-D autoradiography in the rat brain: a cross-validation study

    International Nuclear Information System (INIS)

    Prieto, Elena; Marti-Climent, Josep M.; Collantes, Maria; Molinet, Francisco; Delgado, Mercedes; Garcia-Garcia, Luis; Pozo, Miguel A.; Juri, Carlos; Fernandez-Valle, Maria E.; Gago, Belen; Obeso, Jose A.; Penuelas, Ivan

    2011-01-01

    Although specific positron emission tomography (PET) scanners have been developed for small animals, spatial resolution remains one of the most critical technical limitations, particularly in the evaluation of the rodent brain. The purpose of the present study was to examine the reliability of voxel-based statistical analysis (Statistical Parametric Mapping, SPM) applied to 18 F-fluorodeoxyglucose (FDG) PET images of the rat brain, acquired on a small animal PET not specifically designed for rodents. The gold standard for the validation of the PET results was the autoradiography of the same animals acquired under the same physiological conditions, reconstructed as a 3-D volume and analysed using SPM. Eleven rats were studied under two different conditions: conscious or under inhalatory anaesthesia during 18 F-FDG uptake. All animals were studied in vivo under both conditions in a dedicated small animal Philips MOSAIC PET scanner and magnetic resonance images were obtained for subsequent spatial processing. Then, rats were randomly assigned to a conscious or anaesthetized group for postmortem autoradiography, and slices from each animal were aligned and stacked to create a 3-D autoradiographic volume. Finally, differences in 18 F-FDG uptake between conscious and anaesthetized states were assessed from PET and autoradiography data by SPM analysis and results were compared. SPM results of PET and 3-D autoradiography are in good agreement and led to the detection of consistent cortical differences between the conscious and anaesthetized groups, particularly in the bilateral somatosensory cortices. However, SPM analysis of 3-D autoradiography also highlighted differences in the thalamus that were not detected with PET. This study demonstrates that any difference detected with SPM analysis of MOSAIC PET images of rat brain is detected also by the gold standard autoradiographic technique, confirming that this methodology provides reliable results, although partial volume

  13. Present and future of PET and PET/CT in gynaecologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Musto, Alessandra [Department of Nuclear Medicine, PET Center, Policlinico Sant' Orsola Malpighi, Bologna University, Bologna (Italy); Rampin, Lucia [Department of Nuclear Medicine, PET Center, Radiology, Medical Physics, Santa Maria della Misericordia Hospital, viale tre martiri 140, 45100 Rovigo (Italy); Nanni, Cristina [Department of Nuclear Medicine, PET Center, Policlinico Sant' Orsola Malpighi, Bologna University, Bologna (Italy); Marzola, Maria Cristina [Department of Nuclear Medicine, PET Center, Radiology, Medical Physics, Santa Maria della Misericordia Hospital, viale tre martiri 140, 45100 Rovigo (Italy); Fanti, Stefano [Department of Nuclear Medicine, PET Center, Policlinico Sant' Orsola Malpighi, Bologna University, Bologna (Italy); Rubello, Domenico, E-mail: domenico.rubello@libero.it [Department of Nuclear Medicine, PET Center, Radiology, Medical Physics, Santa Maria della Misericordia Hospital, viale tre martiri 140, 45100 Rovigo (Italy)

    2011-04-15

    Objectives: To review the published data in literature on patients affected by gynaecological malignancies to establish the role of {sup 18}F-FDG positron emission tomography (PET) and PET/CT in comparison to conventional imaging (CI). Materials and methods: All papers specifically addressed to the role of {sup 18}F-FDG PET and PET/CT in gynaecological malignancies published on PubMed/Medline, in abstracts from the principal international congresses, in the guidelines from national Societies that had appeared in literature until November 2009 were considered for the purpose of the present study. Results and conclusions: The use of {sup 18}F-FDG PET, and even more of {sup 18}F-FDG PET/CT, is increasing in the follow up of patients with gynaecologic malignancies and suspected recurrent disease: there is evidence in the literature that {sup 18}F-FDG PET/CT has a higher sensitivity than CI in depicting occult metastatic spread. An interesting issue is represented by patients with ovarian cancer with an increase of the specific biomarker, CA-125, and negative/inconclusive findings at CI. The use of {sup 18}F-FDG PET in differential diagnosis and staging is more controversial, but there is some evidence that a baseline PET examination performed before commencing therapy, for staging purpose, is also useful to evaluate the response to chemoradiation treatment. In several papers it has been suggested a relevant role of {sup 18}F-FDG PET/CT in evaluating the entity of response to treatment and therefore to plan the subsequent therapeutic strategy.

  14. Quantitative and Visual Assessments toward Potential Sub-mSv or Ultrafast FDG PET Using High-Sensitivity TOF PET in PET/MRI.

    Science.gov (United States)

    Behr, Spencer C; Bahroos, Emma; Hawkins, Randall A; Nardo, Lorenzo; Ravanfar, Vahid; Capbarat, Emily V; Seo, Youngho

    2018-06-01

    Newer high-performance time-of-flight (TOF) positron emission tomography (PET) systems have the capability to preserve diagnostic image quality with low count density, while maintaining a high raw photon detection sensitivity that would allow for a reduction in injected dose or rapid data acquisition. To assess this, we performed quantitative and visual assessments of the PET images acquired using a highly sensitive (23.3 cps/kBq) large field of view (25-cm axial) silicon photomultiplier (SiPM)-based TOF PET (400-ps timing resolution) integrated with 3 T-MRI in comparison to PET images acquired on non-TOF PET/x-ray computed tomography (CT) systems. Whole-body 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]FDG) PET/CT was acquired for 15 patients followed by whole body PET/magnetic resonance imaging (MRI) with an average injected dose of 325 ± 84 MBq. The PET list mode data from PET/MRI were reconstructed using full datasets (4 min/bed) and reduced datasets (2, 1, 0.5, and 0.25 min/bed). Qualitative assessment between PET/CT and PET/MR images were made. A Likert-type scale between 1 and 5, 1 for non-diagnostic, 3 equivalent to PET/CT, and 5 superior quality, was used. Maximum and mean standardized uptake values (SUV max and SUV mean ) of normal tissues and lesions detected were measured and compared. Mean visual assessment scores were 3.54 ± 0.32, 3.62 ± 0.38, and 3.69 ± 0.35 for the brain and 3.05 ± 0.49, 3.71 ± 0.45, and 4.14 ± 0.44 for the whole-body maximum intensity projections (MIPs) for 1, 2, and 4 min/bed PET/MR images, respectively. The SUV mean values for normal tissues were lower and statistically significant for images acquired at 4, 2, 1, 0.5, and 0.25 min/bed on the PET/MR, with values of - 18 ± 28 % (p PET/MR datasets. High-sensitivity TOF PET showed comparable but still better visual image quality even at a much reduced activity in comparison to lower-sensitivity non-TOF PET. Our data translates to a seven times

  15. Imaging with 124I in differentiated thyroid carcinoma: is PET/MRI superior to PET/CT?

    International Nuclear Information System (INIS)

    Binse, I.; Poeppel, T.D.; Ruhlmann, M.; Gomez, B.; Bockisch, A.; Rosenbaum-Krumme, S.J.; Umutlu, L.

    2016-01-01

    The aim of this study was to compare integrated PET/CT and PET/MRI for their usefulness in detecting and categorizing cervical iodine-positive lesions in patients with differentiated thyroid cancer using 124 I as tracer. The study group comprised 65 patients at high risk of iodine-positive metastasis who underwent PET/CT (low-dose CT scan, PET acquisition time 2 min; PET/CT 2 ) followed by PET/MRI of the neck 24 h after 124 I administration. PET images from both modalities were analysed for the numbers of tracer-positive lesions. Two different acquisition times were used for the comparisons, one matching the PET/CT 2 acquisition time (2 min, PET/MRI 2 ) and the other covering the whole MRI scan time (30 min, PET/MRI 30 ). Iodine-positive lesions were categorized as metastasis, thyroid remnant or inconclusive according to their location on the PET/CT images. Morphological information provided by MRI was considered for evaluation of lesions on PET/MRI and for volume information. PET/MRI 2 detected significantly more iodine-positive metastases and thyroid remnants than PET/CT 2 (72 vs. 60, p = 0.002, and 100 vs. 80, p = 0.001, respectively), but the numbers of patients with at least one tumour lesion identified were not significantly different (21/65 vs. 17/65 patients). PET/MRI 30 tended to detect more PET-positive metastases than PET/MRI 2 (88 vs. 72), but the difference was not significant (p = 0.07). Of 21 lesions classified as inconclusive on PET/CT, 5 were assigned to metastasis or thyroid remnant when evaluated by PET/MRI. Volume information was available in 34 % of iodine-positive metastases and 2 % of thyroid remnants on PET/MRI. PET/MRI of the neck was found to be superior to PET/CT in detecting iodine-positive lesions. This was attributed to the higher sensitivity of the PET component, Although helpful in some cases, we found no substantial advantage of PET/MRI over PET/CT in categorizing iodine-positive lesions as either metastasis or thyroid remnant

  16. Improved UTE-based attenuation correction for cranial PET-MR using dynamic magnetic field monitoring

    International Nuclear Information System (INIS)

    Aitken, A. P.; Giese, D.; Tsoumpas, C.; Schleyer, P.; Kozerke, S.; Prieto, C.; Schaeffter, T.

    2014-01-01

    Purpose: Ultrashort echo time (UTE) MRI has been proposed as a way to produce segmented attenuation maps for PET, as it provides contrast between bone, air, and soft tissue. However, UTE sequences require samples to be acquired during rapidly changing gradient fields, which makes the resulting images prone to eddy current artifacts. In this work it is demonstrated that this can lead to misclassification of tissues in segmented attenuation maps (AC maps) and that these effects can be corrected for by measuring the true k-space trajectories using a magnetic field camera. Methods: The k-space trajectories during a dual echo UTE sequence were measured using a dynamic magnetic field camera. UTE images were reconstructed using nominal trajectories and again using the measured trajectories. A numerical phantom was used to demonstrate the effect of reconstructing with incorrect trajectories. Images of an ovine leg phantom were reconstructed and segmented and the resulting attenuation maps were compared to a segmented map derived from a CT scan of the same phantom, using the Dice similarity measure. The feasibility of the proposed method was demonstrated inin vivo cranial imaging in five healthy volunteers. Simulated PET data were generated for one volunteer to show the impact of misclassifications on the PET reconstruction. Results: Images of the numerical phantom exhibited blurring and edge artifacts on the bone–tissue and air–tissue interfaces when nominal k-space trajectories were used, leading to misclassification of soft tissue as bone and misclassification of bone as air. Images of the tissue phantom and thein vivo cranial images exhibited the same artifacts. The artifacts were greatly reduced when the measured trajectories were used. For the tissue phantom, the Dice coefficient for bone in MR relative to CT was 0.616 using the nominal trajectories and 0.814 using the measured trajectories. The Dice coefficients for soft tissue were 0.933 and 0.934 for the

  17. Acquiring additional delayed PET images improves sensitivity and specificity in oncology cases

    International Nuclear Information System (INIS)

    Lamki, L.M.; Barron, B.J.; Mullani, N.; Joseph, U.; Ehert, E.

    2002-01-01

    Aim: This study looked into utility of acquiring PET images at 2-3 hours in addition to the standard whole body PET done at 1-hour after FDG injection in certain oncology cases. The objective is to evaluate whether the delayed additional images can decipher equivocal foci of FDG accumulation commonly seen in oncology patients. Typical example is the bowel activity that moves with time. Materials and Methods: PET protocol at our Institution in patients with colon Cancer, Pancreas Ca, Ovarian Ca and Breast Ca include a whole body PET (6-7 bed positions) done at 1-hour after 15 mCi F-18-FDG followed by select limited area PET scan (typically 2 bed stops over the area of interest) at 2-3 hours. Acquisition was undertaken on Siemens ECAT-EXACT Camera - 2-D acquisition and 8 mins. per bed position (5 mins. Emission and 3 mins. Transmission), 16.3 cm FOV and then Iterative Reconstruction. Results: Analysis of the first 115 patients who had additional delayed images resulted in 80% of patients where delayed images helped in interpretation. In 70% of these, delayed images helped in identifying physiological structures, e.g., ureters, bowel, blood vessels and muscles versus pathology. In 25%, they actually helped in identifying malignancy, e.g. more definite FDG accumulation. Almost all helped to boost the confidence of the reader. The contribution was mainly in differentiating bowel and ureter activity from cancer in the abdomen, as these change position with time. In case of pancreas and breast cancer, delayed images contributed in clarifying tumor metabolic activity as well. Inflammation and motion artifacts could also be better defined and so was muscle uptake. Conclusion: (1) Additional delayed PET imaging is very helpful in certain cancers in identifying more lesions and avoiding pitfalls. (2) They can yield higher sensitivity and specificity for colon, ovarian, breast and pancreas cancers. (3) Identification of physiologic structures and differentiation of these from

  18. Exploring the feasibility of iris recognition for visible spectrum iris images obtained using smartphone camera

    Science.gov (United States)

    Trokielewicz, Mateusz; Bartuzi, Ewelina; Michowska, Katarzyna; Andrzejewska, Antonina; Selegrat, Monika

    2015-09-01

    In the age of modern, hyperconnected society that increasingly relies on mobile devices and solutions, implementing a reliable and accurate biometric system employing iris recognition presents new challenges. Typical biometric systems employing iris analysis require expensive and complicated hardware. We therefore explore an alternative way using visible spectrum iris imaging. This paper aims at answering several questions related to applying iris biometrics for images obtained in the visible spectrum using smartphone camera. Can irides be successfully and effortlessly imaged using a smartphone's built-in camera? Can existing iris recognition methods perform well when presented with such images? The main advantage of using near-infrared (NIR) illumination in dedicated iris recognition cameras is good performance almost independent of the iris color and pigmentation. Are the images obtained from smartphone's camera of sufficient quality even for the dark irides? We present experiments incorporating simple image preprocessing to find the best visibility of iris texture, followed by a performance study to assess whether iris recognition methods originally aimed at NIR iris images perform well with visible light images. To our best knowledge this is the first comprehensive analysis of iris recognition performance using a database of high-quality images collected in visible light using the smartphones flashlight together with the application of commercial off-the-shelf (COTS) iris recognition methods.

  19. Magnetic Resonance-based Motion Correction for Quantitative PET in Simultaneous PET-MR Imaging.

    Science.gov (United States)

    Rakvongthai, Yothin; El Fakhri, Georges

    2017-07-01

    Motion degrades image quality and quantitation of PET images, and is an obstacle to quantitative PET imaging. Simultaneous PET-MR offers a tool that can be used for correcting the motion in PET images by using anatomic information from MR imaging acquired concurrently. Motion correction can be performed by transforming a set of reconstructed PET images into the same frame or by incorporating the transformation into the system model and reconstructing the motion-corrected image. Several phantom and patient studies have validated that MR-based motion correction strategies have great promise for quantitative PET imaging in simultaneous PET-MR. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Analysis of the initial experience with first PET scanner and in Chile

    International Nuclear Information System (INIS)

    Massardo, Teresa; Jofre, Maria Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Valdebenito, Robert; Galaz, Rodrigo

    2005-01-01

    The main application of positron emission tomography (PET) with Fluorine 18- deoxyglucose (FDG) is in the management of cancer patients due to the high correlation between cellular glucidic activity and malignancy. Objective: To analyze the initial group of cases performed with the first dedicated PET scanner in Chile. Method: We present the first 500 patients studied with a Siemens HR+ system using FDG produced at the Chilean Atomic Energy Commission facilities. Results: Most of the referrals were from oncology (96%). Four percent were studied due to neurological or psychiatric disorders and only 1% for myocardial viability. Lung lesions, gastrointestinal and breast carcinomas, melanoma and lymphoma corresponded to the most frequent diagnosis. Lung and lymphoma patients had clinical follow-up. There was good concordance with anatomical images and histology in those cases with available data. Fusion of FDG images with computed tomography or magnetic resonance was helpful. In a significant number of patients new tumoral sites were detected Conclusion: We confirm that in clinical practice, metabolic imaging with F18-FDG is helpful for cancer evaluation and management (au)

  1. Analysis of the initial experience with first PET scanner and in Chile

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa; Jofre, Maria Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Valdebenito, Robert; Galaz, Rodrigo [Centro PET de Imagenes Moleculares, Hospital Militar da Santiago, Santiago (Chile)

    2005-07-01

    The main application of positron emission tomography (PET) with Fluorine 18- deoxyglucose (FDG) is in the management of cancer patients due to the high correlation between cellular glucidic activity and malignancy. Objective: To analyze the initial group of cases performed with the first dedicated PET scanner in Chile. Method: We present the first 500 patients studied with a Siemens HR+ system using FDG produced at the Chilean Atomic Energy Commission facilities. Results: Most of the referrals were from oncology (96%). Four percent were studied due to neurological or psychiatric disorders and only 1% for myocardial viability. Lung lesions, gastrointestinal and breast carcinomas, melanoma and lymphoma corresponded to the most frequent diagnosis. Lung and lymphoma patients had clinical follow-up. There was good concordance with anatomical images and histology in those cases with available data. Fusion of FDG images with computed tomography or magnetic resonance was helpful. In a significant number of patients new tumoral sites were detected Conclusion: We confirm that in clinical practice, metabolic imaging with F18-FDG is helpful for cancer evaluation and management (au)

  2. Sensory analysis of pet foods.

    Science.gov (United States)

    Koppel, Kadri

    2014-08-01

    Pet food palatability depends first and foremost on the pet and is related to the pet food sensory properties such as aroma, texture and flavor. Sensory analysis of pet foods may be conducted by humans via descriptive or hedonic analysis, pets via acceptance or preference tests, and through a number of instrumental analysis methods. Sensory analysis of pet foods provides additional information on reasons behind palatable and unpalatable foods as pets lack linguistic capabilities. Furthermore, sensory analysis may be combined with other types of information such as personality and environment factors to increase understanding of acceptable pet foods. Most pet food flavor research is proprietary and, thus, there are a limited number of publications available. Funding opportunities for pet food studies would increase research and publications and this would help raise public awareness of pet food related issues. This mini-review addresses current pet food sensory analysis literature and discusses future challenges and possibilities. © 2014 Society of Chemical Industry.

  3. Use of a clinical PET/MR scanner for preclinical research with first results

    International Nuclear Information System (INIS)

    Chary, Karthik; Teuho, Jarmo; Virta, Jenni; Sipilä, Hannu; Saunavaara, Virva; Roivainen, Anne; Teräs, Mika

    2014-01-01

    This study was performed to evaluate the feasibility of preclinical imaging in a clinical PET/MR system. Preliminary sequences were evaluated for establishing preclinical protocols for rat brain and rabbit knee. Rats were placed in a stereotactic holder, allowing a 30 minute scan time before re-administration of anesthesia. In-house developed warm-water heating system was used to maintain the body temperature at 37.5°C, monitored using an MR-compatible rectal probe. Brain imaging was performed with a dedicated 4 channel phased array receive coil (RAPID Biomedical GmbH, Germany). High resolution coronal images were acquired using conventional T1-SE (0.30x0.30x1.2mm) and T2-TSE (0.23x0.23x0.7mm) with a total scan time of 30 min. PET/MR imaging was performed on two white rabbits. The rabbits were imaged in a custom wooden holder. PET/MR protocol had a total duration of 45 minutes. No external heating was used. MR protocol consisted of anatomical T1, T2 and PDW of the knees, using a SENSE Flex-S coil. MR attenuation correction (MRAC) was acquired with 3D T1-FFE using three-class segmentation. A dynamic 30 minute PET acquisition was started on injection of 33.8MBq of Ga-68. Animal coils enabled high resolution images to be acquired in reasonable acquisition time with regards to animal handling and anesthesia. T1 and T2 images provided good differentiation of anatomy in the rat brain with high contrast. T1, T2 and PDW images of the rabbit knee had high resolution and differentiation of anatomical structures. MRAC was able to distinguish the knees and the body contour. Image fusion of PET and MR was able to localize the infection, which was confirmed by a physician. Pre-clinical imaging with the Ingenuity TF was deemed feasible, although PET imaging is limited by the resolution of the scanner. The preliminary sequences were successfully implemented for future studies on the Ingenuity TF.

  4. Use of a clinical PET/MR scanner for preclinical research with first results

    Energy Technology Data Exchange (ETDEWEB)

    Chary, Karthik; Teuho, Jarmo; Virta, Jenni; Sipilä, Hannu; Saunavaara, Virva; Roivainen, Anne; Teräs, Mika [Turku PET Centre, Turku University Hospital, Turku (Finland)

    2014-07-29

    This study was performed to evaluate the feasibility of preclinical imaging in a clinical PET/MR system. Preliminary sequences were evaluated for establishing preclinical protocols for rat brain and rabbit knee. Rats were placed in a stereotactic holder, allowing a 30 minute scan time before re-administration of anesthesia. In-house developed warm-water heating system was used to maintain the body temperature at 37.5°C, monitored using an MR-compatible rectal probe. Brain imaging was performed with a dedicated 4 channel phased array receive coil (RAPID Biomedical GmbH, Germany). High resolution coronal images were acquired using conventional T1-SE (0.30x0.30x1.2mm) and T2-TSE (0.23x0.23x0.7mm) with a total scan time of 30 min. PET/MR imaging was performed on two white rabbits. The rabbits were imaged in a custom wooden holder. PET/MR protocol had a total duration of 45 minutes. No external heating was used. MR protocol consisted of anatomical T1, T2 and PDW of the knees, using a SENSE Flex-S coil. MR attenuation correction (MRAC) was acquired with 3D T1-FFE using three-class segmentation. A dynamic 30 minute PET acquisition was started on injection of 33.8MBq of Ga-68. Animal coils enabled high resolution images to be acquired in reasonable acquisition time with regards to animal handling and anesthesia. T1 and T2 images provided good differentiation of anatomy in the rat brain with high contrast. T1, T2 and PDW images of the rabbit knee had high resolution and differentiation of anatomical structures. MRAC was able to distinguish the knees and the body contour. Image fusion of PET and MR was able to localize the infection, which was confirmed by a physician. Pre-clinical imaging with the Ingenuity TF was deemed feasible, although PET imaging is limited by the resolution of the scanner. The preliminary sequences were successfully implemented for future studies on the Ingenuity TF.

  5. The application of PET and PET-CT in cervical cancer

    International Nuclear Information System (INIS)

    Huang Jianmin; Pan Liping; Li Dongxue

    2007-01-01

    Cervical cancer is the common malignancies in woman, 18 F-fluorodeoxyglucose ( 18 F-FDG) PET is a well-established method for detecting, staging, cancer recurrence, therapeutic response and prognosis of cervical cancer. PET-CT can accurately locate the anatomical sites of tracer uptake and improve the diagnostic accuraccy of PET. (authors)

  6. Development and evaluation of a practical method to measure the Depth of Interaction function for a single side readout PET detector

    CERN Document Server

    Stringhini, G.; Ghezzi, A.; Stojkovic, A.; Paganoni, M.; Auffray, E.

    2016-01-01

    In small animal and organ dedicated PET scanners, the knowledge of depth of interaction (DOI) of the gamma ray along the main axis of the scintillator is a fundamental information in order to avoid parallax error and to achieve high performances in terms of spatial resolution. Recently we developed a new method to obtain the DOI function for a single side readout PET module, recirculating the scintillation light in the matrix by means of a mirror placed on top of the module. In a complete PET scanner, periodical DOI calibrations have to be performed to prevent time dependent miscalibrations and performance degradations. The current DOI calibration relies on a coincidence system between the module and an external scintillator to provide a priori the DOI information and it is clearly not feasible in a real system without unpractical disassemblies of the scanner. In this paper we develop instead a fast and precise calibration method based on uniform irradiation of the scintillators. Three irradiation modalities ...

  7. Utility of 18F sodium fluoride PET/CT imaging in the evaluation of postoperative pain following surgical spine fusion.

    Science.gov (United States)

    Pouldar, D; Bakshian, S; Matthews, R; Rao, V; Manzano, M; Dardashti, S

    2017-08-01

    A retrospective case review of patients who underwent 18F sodium fluoride PET/CT imaging of the spine with postoperative pain following vertebral fusion. To determine the benefit of 18F sodium fluoride PET/CT imaging in the diagnosis of persistent pain in the postoperative spine. The diagnosis of pain generators in the postoperative spine has proven to be a diagnostic challenge. The conventional radiologic evaluation of persistent pain after spine surgery with the use of plain radiographs, MRI, and CT can often fall short of diagnosis in the complex patient. 18F sodium fluoride PET/CT imaging is an alternative tool to accurately identify a patient's source of pain in the difficult patient. This retrospective study looked at 25 adult patients who had undergone 18F sodium fluoride PET/CT imaging. All patients had persistent or recurrent back pain over the course of a 15-month period after having undergone spinal fusion surgery. All patients had inconclusive dedicated MRI. The clinical accuracy of PET/CT in identifying the pain generator and contribution to altering the decision making process was compared to the use of CT scan alone. Of the 25 patients studied, 17 patients had increased uptake on the 18F sodium fluoride PET/CT fusion images. There was a high-level correlation of radiotracer uptake to the patients' pain generator. Overall 88% of the studies were considered beneficial with either PET/CT altering the clinical diagnosis and treatment plan of the patient or confirming unnecessary surgery. 18F sodium fluoride PET/CT proves to be a useful tool in the diagnosis of complex spine pathology of the postoperative patients. In varied cases, a high correlation of metabolic activity to the source of the patient's pain was observed.

  8. The petit rat (pet/pet), a new semilethal mutant dwarf rat with thymic and testicular anomalies.

    Science.gov (United States)

    Chiba, Junko; Suzuki, Katsushi; Suzuki, Hiroetsu

    2008-12-01

    The petit rat (pet/pet) is a recently discovered semilethal mutant dwarf. The neonatal pet/pet rats had a low body weight and small thymus and testis. During the first 3 d after birth, 50% of the male and 80% of the female pet/pet pups were lost or found dead. Surviving pet/pet rats showed marked retardation of postnatal growth, and their body weights were 41% (female rats) and 32% (male rats) of those of normal rats at the adult stage. The pet/pet rats exhibited proportional dwarfism, and their longitudinal bones were shorter than those of controls without skeletal malformations. Most organs of male pet/pet rats, especially the thymus, testis, adipose tissue surrounding the kidney, and accessory sex organs, weighed markedly less at 140 d of age than did those of their normal counterparts. The thymus of pet/pet rats was small with abnormal thymic follicles. Testes from pet/pet rats exhibited 2 patterns of abnormal histology. Spermatogenesis was present in testes that were only slightly anomalous, but the seminiferous tubules were reduced in diameter. In severely affected testes, most of the seminiferous tubules showed degeneration, and interstitial tissue was increased. Plasma growth hormone concentrations did not differ between pet/pet and normal male rats. The dwarf phenotype of pet/pet rats was inherited as an autosomal recessive trait. These results indicate that the pet/pet rat has a semilethal growth-hormone-independent dwarf phenotype that is accompanied by thymic and testicular anomalies and low birth weight.

  9. Value of PET and PET-CT for monitoring tumor therapy

    International Nuclear Information System (INIS)

    Chen Xiang; Zhao Jinhua

    2007-01-01

    18 F-fluorodeoxyglucose ( 18 F-FDG) PET or PET-CT is an accurate test for differentiating residual viable tumor tissue from therapy-induced changes in tumor. Furthermore, quantitative assessment of therapy-induced changes in tumor 18 F-FDG uptake may allow the prediction of tumor response. Treatment may be adjusted according to tumor response. So it is increasingly used to monitor tumor response in patients undergoing chemotherapy and chemoradiotherapy. Here we focused on practical aspects of 18 F-FDG PET or PET-CT for treatment monitoring and on the existing advantages and challenges. (authors)

  10. Comparative evaluation of consumer grade cameras and mobile phone cameras for close range photogrammetry

    Science.gov (United States)

    Chikatsu, Hirofumi; Takahashi, Yoji

    2009-08-01

    The authors have been concentrating on developing convenient 3D measurement methods using consumer grade digital cameras, and it was concluded that consumer grade digital cameras are expected to become a useful photogrammetric device for the various close range application fields. On the other hand, mobile phone cameras which have 10 mega pixels were appeared on the market in Japan. In these circumstances, we are faced with alternative epoch-making problem whether mobile phone cameras are able to take the place of consumer grade digital cameras in close range photogrammetric applications. In order to evaluate potentials of mobile phone cameras in close range photogrammetry, comparative evaluation between mobile phone cameras and consumer grade digital cameras are investigated in this paper with respect to lens distortion, reliability, stability and robustness. The calibration tests for 16 mobile phone cameras and 50 consumer grade digital cameras were conducted indoors using test target. Furthermore, practability of mobile phone camera for close range photogrammetry was evaluated outdoors. This paper presents that mobile phone cameras have ability to take the place of consumer grade digital cameras, and develop the market in digital photogrammetric fields.

  11. Processing and characterization of extruded PET and its r-PET and ...

    Indian Academy of Sciences (India)

    of r-PET and r-PET+ MWCNT fillers was obtained by the precipitation method using TFA as a solvent and acetone ... crystallinity in r-PET and decrease in chain entanglements. ..... insufficient to supply the complete information of the surface.

  12. Gamma camera

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.; Baer, U.; Heinz, L.

    1978-01-01

    A gamma camera has a plurality of exchangeable collimators, one of which is mounted in the ray inlet opening of the camera, while the others are placed on separate supports. The supports are swingably mounted upon a column one above the other through about 90 0 to a collimator exchange position. Each of the separate supports is swingable to a vertically aligned position, with limiting of the swinging movement and positioning of the support at the desired exchange position. The collimators are carried on the supports by means of a series of vertically disposed coil springs. Projections on the camera are movable from above into grooves of the collimator at the exchange position, whereupon the collimator is turned so that it is securely prevented from falling out of the camera head

  13. Characterization and commissioning of the SST-1M camera for the Cherenkov Telescope Array

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar, J.A. [Université Libre Bruxelles, Faculté des Sciences, Avenue Franklin Roosevelt 50, 1050 Brussels (Belgium); DPNC - Université de Genéve, 24 Quai Ernest Ansermet, Genéve (Switzerland); Department of Information Technologies, Jagiellonian University, ul. prof. Stanisława Łojasiewicza 11, 30–348 Kraków (Poland); Bilnik, W. [AGH University of Science and Technology, al.Mickiewicza 30, Kraków (Poland); Department of Information Technologies, Jagiellonian University, ul. prof. Stanisława Łojasiewicza 11, 30–348 Kraków (Poland); Błocki, J. [Instytut Fizyki Jadrowej im. H. Niewodniczańskiego Polskiej Akademii Nauk, ul. Radzikowskiego 152, 31–342 Kraków (Poland); Department of Information Technologies, Jagiellonian University, ul. prof. Stanisława Łojasiewicza 11, 30–348 Kraków (Poland); Bogacz, L. [Astronomical Observatory, Jagiellonian University, ul. Orla 171, 30–244 Kraków (Poland); Department of Information Technologies, Jagiellonian University, ul. prof. Stanisława Łojasiewicza 11, 30–348 Kraków (Poland); and others

    2017-02-11

    The Cherenkov Telescope Array (CTA), the next generation very high energy gamma-rays observatory, will consist of three types of telescopes: large (LST), medium (MST) and small (SST) size telescopes. The SSTs are dedicated to the observation of gamma-rays with energy between a few TeV and a few hundreds of TeV. The SST array is expected to have 70 telescopes of different designs. The single-mirror small size telescope (SST-1 M) is one of the proposed telescope designs under consideration for the SST array. It will be equipped with a 4 m diameter segmented mirror dish and with an innovative camera based on silicon photomultipliers (SiPMs). The challenge is not only to build a telescope with exceptional performance but to do it foreseeing its mass production. To address both of these challenges, the camera adopts innovative solutions both for the optical system and readout. The Photo-Detection Plane (PDP) of the camera is composed of 1296 pixels, each made of a hollow, hexagonal light guide coupled to a hexagonal SiPM designed by the University of Geneva and Hamamatsu. As no commercial ASIC would satisfy the CTA requirements when coupled to such a large sensor, dedicated preamplifier electronics have been designed. The readout electronics also use an innovative approach in gamma-ray astronomy by adopting a fully digital approach. All signals coming from the PDP are digitized in a 250 MHz Fast ADC and stored in ring buffers waiting for a trigger decision to send them to the pre-processing server where calibration and higher level triggers will decide whether the data are stored. The latest generation of FPGAs is used to achieve high data rates and also to exploit all the flexibility of the system. As an example each event can be flagged according to its trigger pattern. All of these features have been demonstrated in laboratory measurements on realistic elements and the results of these measurements will be presented in this contribution.

  14. PET and PET/CT in tumour of undetermined origin

    International Nuclear Information System (INIS)

    Garcia O, J.R.

    2007-01-01

    In this presentation the following conclusions were obtained regarding the use of PET and PET/CT in patient with cancer of unknown primary: 1. Detection of the primary one in 1/3 at 1/2 of patient. 2. It detects metastases in other places in 50%. 3. It changes the initial therapy planned in 1/3 at 1/2 of patient. 4. Useful in initial phases of protocol study to limit the other procedures. After standard evaluation. Before advanced protocol. 5. PET/CT study increases the % of primary detection, although in a non significant way vs. PET. 6. They are required more studies to value their utility to a more objective manner. (Author)

  15. Clinical applications of PET/CT

    International Nuclear Information System (INIS)

    Le Ngoc Ha

    2011-01-01

    The purpose of this article is to review the evolution of PET, PET/CT focusing on the technical aspects, PET radiopharmaceutical developments and current clinical applications as well. The newest technologic advances have been reviewed, including improved crystal design, acquisition modes, reconstruction algorithms, etc. These advancements will continue to improve contrast, decrease noise, and increase resolution. Combined PET/CT system provides faster attenuation correction and useful anatomic correlation to PET functional information. A number of new radiopharmaceuticals used for PET imaging have been developed, however, FDG have been considered as the principal PET radiotracer. The current clinical applications of PET and PET/CT are widespread and include oncology, cardiology and neurology. (author)

  16. Development of the LBNL positron emission mammography camera

    International Nuclear Information System (INIS)

    Huber, Jennifer S.; Choong, Woon-Seng; Wang, Jimmy; Maltz, Jonathon S.; Qi, Jinyi; Mandelli, Emanuele; Moses, William W.

    2002-01-01

    We present the construction status of the LBNL Positron Emission Mammography (PEM) camera, which utilizes a PET detector module with depth of interaction measurement consisting of 64 LSO crystals (3x3x30 mm3) coupled on one end to a single photomultiplier tube (PMT) and on the opposite end to a 64 pixel array of silicon photodiodes (PDs). The PMT provides an accurate timing pulse, the PDs identify the crystal of interaction, the sum provides a total energy signal, and the PD/(PD+PMT) ratio determines the depth of interaction. We have completed construction of all 42 PEM detector modules. All data acquisition electronics have been completed, fully tested and loaded onto the gantry. We have demonstrated that all functions of the custom IC work using the production rigid-flex boards and data acquisition system. Preliminary detector module characterization and coincidence data have been taken using the production system, including initial images

  17. A new gamma camera for positron emission tomography

    International Nuclear Information System (INIS)

    Schotanus, P.

    1988-01-01

    This thesis describes the detection of annihiliation radiation employing a new principle: radiation is absorbed in a barium fluoride (BaF 2) crystal and the resulting scintillation light is detected in a multiwire proportional chamber filled with a photsensitive vapour. The application of such a detector for PET is new; the use of a high density fast scintillator in combination with a low pressure wire chamber offers a good detection efficiency and permits high count rates because of the small dead time. In this work, the physical background of the above detection mechanism is explored and the performance parameters of a gamma camera using this new principle, are determined. Furthermore, a comprehensive research on the scintillation mechanism and physical characteristics of the increasingly popular BaF 2 scintillator is presented. Also, a new class of ultraviolet (UV) scintillation materials, consisting of rare earth doped fluorides, is introduced. (author). 211 refs.; 30 figs.; 17 tabs

  18. SENSITIVITY TEMPERATURE DEPENDENCE RESEARCH OF TV-CAMERAS BASED ON SILICON MATRIXES

    Directory of Open Access Journals (Sweden)

    Alexey N. Starchenko

    2017-07-01

    Full Text Available Subject of Research. The research is dedicated to the analysis of sensitivity change patterns of the cameras based on silicon CMOS-matrixes in various ambient temperatures. This information is necessary for the correct camera application for photometric measurements in-situ. The paper deals with studies of sensitivity variations of two digital cameras with different silicon CMOS matrixes in visible and near IR regions of the spectrum at temperature change. Method. Due to practical restrictions the temperature changes were recorded in separate spectral intervals important for practical use of the cameras. The experiments were carried out with the use of a climatic chamber, providing change and keeping the temperature range from minus 40 to plus 50 °C at a pitch of 10 о С. Two cameras were chosen for research: VAC-135-IP with OmniVision OV9121 matrix and VAC-248-IP with OnSemiconductor VITA2000 matrix. The two tested devices were placed in a climatic chamber at the same time and illuminated by one radiation source with a color temperature about 3000 K in order to eliminate a number of methodological errors. Main Results. The temperature dependence of the signals was shown to be linear and the matrixes sensitivities were determined. The results obtained are consistent with theoretical views, in general. The coefficients of thermal sensitivity were computed by these dependencies. It is shown that the greatest affect of temperature on the sensitivity occurs in the area (0.7–1.1 mkm. Temperature coefficients of sensitivity increase with the downward radiation wavelength increase. The experiments carried out have shown that it is necessary to take into account the changes in temperature sensitivity of silicon matrixes in the red and near in IR regions of the spectrum. The effect reveals itself in a clearly negative way in cameras with an amplitude resolution of 10-12 bits used for aerospace and space spectrozonal photography. Practical Relevance

  19. Joint project of the international network of agencies for health technology assessment--Part 1: Survey results on diffusion, assessment, and clinical use of positron emission tomography.

    Science.gov (United States)

    Hastings, John; Adams, Elizabeth J

    2006-01-01

    The International Network of Agencies for Health Technology Assessment (INAHTA) has been tracking activities associated with the clinical use of positron emission tomography (PET) in its members' healthcare systems since 1997 and published its first Joint Project report on PET in 1999. Part 1 of this Joint Project report presents survey results on diffusion, assessment activities, and policy for clinical use related to PET among INAHTA members since 1999. INAHTA members were surveyed in 2003-2004. Twenty-seven INAHTA agencies (69 percent response rate) from nineteen countries responded to the survey. Dedicated PET systems are the most universally installed systems to date. Mobile scanners and modified gamma cameras are used occasionally as lower cost alternatives, and interest in PET-computed tomography hybrid models is rising despite limited assessment of impact on service planning. PET was used and assessed most commonly for managing patients with cancer. All respondents reported having some form of public funding for clinical PET frequently linked to data collection for the purpose of gathering evidence to refine clinical use and guide resource allocation toward indications that maximize clinical and cost-effectiveness. The use of HTA within a continuous quality improvement framework can help optimize scarce resources for evaluation and use of high cost diagnostic technologies such as PET, particularly where potential clinical or cost-effectiveness is considerable but conclusive evidence is lacking.

  20. Dedication increases productivity: an analysis of the implementation of a dedicated medical team in the emergency department.

    Science.gov (United States)

    Ramos, Pedro; Paiva, José Artur

    2017-12-01

    In several European countries, emergency departments (EDs) now employ a dedicated team of full-time emergency medicine (EM) physicians, with a distinct leadership and bed-side emergency training, in all similar to other hospital departments. In Portugal, however, there are still two very different models for staffing EDs: a classic model, where EDs are mostly staffed with young inexperienced physicians from different medical departments who take turns in the ED in 12-h shifts and a dedicated model, recently implemented in some hospitals, where the ED is staffed by a team of doctors with specific medical competencies in emergency medicine that work full-time in the ED. Our study assesses the effect of an intervention in a large academic hospital ED in Portugal in 2002, and it is the first to test the hypothesis that implementing a dedicated team of doctors with EM expertise increases the productivity and reduces costs in the ED, maintaining the quality of care provided to patients. A pre-post design was used for comparing the change on the organisational model of delivering care in our medical ED. All emergency medical admissions were tracked in 2002 (classic model with 12-h shift in the ED) and 2005/2006 (dedicated team with full-time EM physicians), and productivity, costs with medical human resources and quality of care measures were compared. We found that medical productivity (number of patients treated per hour of medical work) increased dramatically after the creation of the dedicated team (X 2 KW = 31.135; N = 36; p work reduced both in regular hours and overtime. Moreover, hospitalisation rates decreased and the length of stay in the ED increased significantly after the creation of the dedicated team. Implementing a dedicated team of doctors increased the medical productivity and reduced costs in our ED. Our findings have straightforward implication for Portuguese policymakers aiming at reducing hospital costs while coping with increased ED demand.

  1. Diagnosis and dosimetry in differentiated thyroid carcinoma using 124I PET: comparison of PET/MRI vs PET/CT of the neck

    International Nuclear Information System (INIS)

    Nagarajah, James; Jentzen, Walter; Hartung, Verena; Rosenbaum-Krumme, Sandra; Bockisch, Andreas; Stahl, Alexander; Mikat, Christian; Heusner, Till Alexander; Antoch, Gerald

    2011-01-01

    This study compares intrinsically coregistered 124 I positron emission tomography (PET) and CT (PET/CT) and software coregistered 124 I PET and MRI (PET/MRI) images for the diagnosis and dosimetry of thyroid remnant tissues and lymph node metastases in patients with differentiated thyroid carcinoma (DTC). After thyroidectomy, 33 high-risk DTC patients (stage III or higher) received 124 I PET/CT dosimetry prior to radioiodine therapy to estimate the absorbed dose to lesions and subsequently underwent a contrast-enhanced MRI examination of the neck. Images were evaluated by two experienced nuclear medicine physicians and two radiologists to identify the lesions and to categorize their presumable provenience, i.e. thyroid remnant tissue (TT), lymph node metastasis (LN) and inconclusive tissue. The categorization and dosimetry of lesions was initially performed with PET images alone (PET only). Subsequently lesions were reassessed including the CT and MRI data. The analyses were performed on a patient and on a lesion basis. Patient-based analyses showed that 26 of 33 (79%) patients had at least one lesion categorized as TT on PET only. Of these patients, 11 (42%) and 16 (62%) had a morphological correlate on CT and MRI, respectively, in at least one TT PET lesion. Twelve patients (36%) had at least one lesion classified as LN on PET only. Nine (75%) of these patients had a morphological correlate on both CT and MRI in at least one LN PET lesion. Ten patients (30%) showed at least one lesion on PET only classified as inconclusive. The classification was changed to a clear classification in two patients (two LN) by CT and in four (two TT, two LN) patients by MRI. Lesion-based analyses (n = 105 PET positive lesions) resulted in categorization as TT in 61 cases (58%), 16 (26%) of which had a morphological correlate on CT and 33 (54%) on MRI. A total of 29 lesions (27%) were classified as LN on PET, 18 (62%) of which had a morphological correlate on CT and 24 (83%) on MRI

  2. Clinical Application of F-18 FDG PET (PET/CT) in Colo-rectal and Anal Cancer

    International Nuclear Information System (INIS)

    Kim, Byung Il

    2008-01-01

    In the management of colo-retal and anal cancer, accurate staging, treatment evaluation, early detection of recurrence are main clinical problems. F-18 FDG PET (PET/CT) has been reported as useful in the management of colo-rectal and anal cancer because that PET has high diagnostic performance comparing to conventional studies. In case of liver metastases, for confirmation of no extrahepatic metastases, in case of high risk of metastasis, for avoiding unnecessary operation, PET (PET/CT) is expected more useful. In anal cancer, PET is expected useful in lymph node staging. For the early prediction of chemotherapy or radiation therapy effect PET has been reported as useful, also. In early detection of recurrence by PET, cost-benefit advantages has been suggested, also. PET/CT is expected to have higher diagnostic performance than PET alone

  3. PET and SPECT in medically non-refractory complex partial seizures. Temporal asymmetries of glucose consumption, Benzodiazepine receptor density

    International Nuclear Information System (INIS)

    Matheja, P.; Kuwert, T.; Wolf, K.; Schober, O.; Stodieck, S.R.G.; Diehl, B.; Ringelstein, E.B.; Schuierer, G.

    1998-01-01

    Aim: In contrast to medically refractory complex partial seizures (CPS), only limited knowledge exists on cerebral perfusion and metabolism in medically non-refractory CPS. The aim of this study was to investigate the frequency of temporal asymmetries in regional cerebral glucose consumption (rCMRGlc), regional cerebral blood flow (rCBF), and regional cerebral benzodiazepine receptor density (BRD) in this group of patients. Methods: The study included 49 patients with medically non-refractory cryptogenic CPS (age: 36.0±16.1 years). rCMRGlc was studied with F-18-FDG-PET (FDG), rCBF with Tc-99m-ECD-SPECT (ECD), and BRD with I-123-iomazenil-SPECT (IMZ). All studies were performed interictally and within four weeks in each patient. Duration of epilepsy ranged from 0.1 to 42 years (median 4.0 years). SPECT was performed with the triple-headed SPECT camera Multispect 3, PET with the PET camera ECAT EXACT 47. Using linear profiles, glucose consumption, as well as uptake of ECD and IMZ, were measured in four temporal regions of interest (ROIs), and asymmetry indices were calculated (ASY). The results were compared to 95% confidence intervals determined in control subjects. Results: Thirty-five of the 49 (71%) patients had at least one significantly elevated ASY; temporal rCMRGlc was asymmetrical in 41% of the patients, temporal BRD in 29%, and temporal rCBF in 24%. One patient had an asymmetry of all three variables, two of temporal rCMRGlc and BRD, three of temporal rCMRGlc and rCBF, and another four of rCBF and BRD. Fourteen patients had an isolated temporal asymmetry in rCMRGlc, seven in BRD, and four in rCBF. A discrepancy in lateralization between the three modalities was not observed. Conclusion: The majority of patients with medically non-refractory CPS have focal abnormalities of blood flow and metabolism in their temporal lobe. In this group of patients, FDG-PET demonstrates abnormalities with the highest frequency of the three modalities studied, followed by IMZ

  4. Data-driven gating in PET: Influence of respiratory signal noise on motion resolution.

    Science.gov (United States)

    Büther, Florian; Ernst, Iris; Frohwein, Lynn Johann; Pouw, Joost; Schäfers, Klaus Peter; Stegger, Lars

    2018-05-21

    Data-driven gating (DDG) approaches for positron emission tomography (PET) are interesting alternatives to conventional hardware-based gating methods. In DDG, the measured PET data themselves are utilized to calculate a respiratory signal, that is, subsequently used for gating purposes. The success of gating is then highly dependent on the statistical quality of the PET data. In this study, we investigate how this quality determines signal noise and thus motion resolution in clinical PET scans using a center-of-mass-based (COM) DDG approach, specifically with regard to motion management of target structures in future radiotherapy planning applications. PET list mode datasets acquired in one bed position of 19 different radiotherapy patients undergoing pretreatment [ 18 F]FDG PET/CT or [ 18 F]FDG PET/MRI were included into this retrospective study. All scans were performed over a region with organs (myocardium, kidneys) or tumor lesions of high tracer uptake and under free breathing. Aside from the original list mode data, datasets with progressively decreasing PET statistics were generated. From these, COM DDG signals were derived for subsequent amplitude-based gating of the original list mode file. The apparent respiratory shift d from end-expiration to end-inspiration was determined from the gated images and expressed as a function of signal-to-noise ratio SNR of the determined gating signals. This relation was tested against additional 25 [ 18 F]FDG PET/MRI list mode datasets where high-precision MR navigator-like respiratory signals were available as reference signal for respiratory gating of PET data, and data from a dedicated thorax phantom scan. All original 19 high-quality list mode datasets demonstrated the same behavior in terms of motion resolution when reducing the amount of list mode events for DDG signal generation. Ratios and directions of respiratory shifts between end-respiratory gates and the respective nongated image were constant over all

  5. Clinical Application of F-18 FDG PET (PET/CT) in Malignancy of Unknown Origin

    International Nuclear Information System (INIS)

    Kim, Byung Il

    2008-01-01

    Diagnosis of primary origin site in the management of malignancy of unknown origin (MUO) is the most important issue. According to the histopathologic subtype of primary lesion, specialized treatment can be given and survival gain is expected. F-18 FDG PET (PET/CT) has been estimated as useful in detection of primary lesion with high sensitivity and moderate specificity. F-18 FDG PET (PET/CT) study before conventional studies is also recommended because it has high diagnostic performance compared to conventional studies. Although there has few data, F-18 FDG PET (PET/CT) is expected to be useful in diagnosis of recurrence, restaging, evaluation of treatment effect, considering that PET (PET/CT) has been reported as useful in other malignancies

  6. Basic study of entire whole-body PET scanners based on the OpenPET geometry

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Eiji, E-mail: rush@nirs.go.j [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan); Yamaya, Taiga; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan)

    2010-09-21

    A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But single data loss at the grouping circuits and multiple coincidences are limited to the peak noise equivalent count rate (NECR) for the entire whole-body PET scanner.

  7. The Rutherford Appleton Laboratory's Mark I multiwire proportional counter positron camera

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Tappern, G.J.; Flesher, A.C.

    1984-01-01

    A small (30 cmx30 cm) model of a proposed large aperture positron camera has been developed at Rutherford Appleton Laboratory. Based on multiwire proportional counter technology, it uses lead foil cathodes which function simultaneously as converters for the 511 keV gamma rays and readout electrodes for a delay line readout system. The detectors have been built up into a portable imaging system complete with a dedicated computer for data taking, processing and display. This has permitted evaluation of this type of positron imaging system in the clinical environment using both cyclotron generated isotopes ( 15 O, 11 C, 18 F, 124 I) and available isotopic generator systems ( 82 Rb, 68 Ga). AT RAL we provided a complete hardware system and sufficient software to permit our hospital based colleagues to generate useful images with the minimum of effort. A complete description of the system is given with performance figures and some of the images obtained in three hospital visits are presented. Some detailed studies of the imaging performance of the positron camera are reported which have bearing on the design of future, improved systems. (orig.)

  8. Characterization of highly multiplexed monolithic PET / gamma camera detector modules

    Science.gov (United States)

    Pierce, L. A.; Pedemonte, S.; DeWitt, D.; MacDonald, L.; Hunter, W. C. J.; Van Leemput, K.; Miyaoka, R.

    2018-04-01

    PET detectors use signal multiplexing to reduce the total number of electronics channels needed to cover a given area. Using measured thin-beam calibration data, we tested a principal component based multiplexing scheme for scintillation detectors. The highly-multiplexed detector signal is no longer amenable to standard calibration methodologies. In this study we report results of a prototype multiplexing circuit, and present a new method for calibrating the detector module with multiplexed data. A 50 × 50 × 10 mm3 LYSO scintillation crystal was affixed to a position-sensitive photomultiplier tube with 8 × 8 position-outputs and one channel that is the sum of the other 64. The 65-channel signal was multiplexed in a resistive circuit, with 65:5 or 65:7 multiplexing. A 0.9 mm beam of 511 keV photons was scanned across the face of the crystal in a 1.52 mm grid pattern in order to characterize the detector response. New methods are developed to reject scattered events and perform depth-estimation to characterize the detector response of the calibration data. Photon interaction position estimation of the testing data was performed using a Gaussian Maximum Likelihood estimator and the resolution and scatter-rejection capabilities of the detector were analyzed. We found that using a 7-channel multiplexing scheme (65:7 compression ratio) with 1.67 mm depth bins had the best performance with a beam-contour of 1.2 mm FWHM (from the 0.9 mm beam) near the center of the crystal and 1.9 mm FWHM near the edge of the crystal. The positioned events followed the expected Beer–Lambert depth distribution. The proposed calibration and positioning method exhibited a scattered photon rejection rate that was a 55% improvement over the summed signal energy-windowing method.

  9. Imaging with {sup 124}I in differentiated thyroid carcinoma: is PET/MRI superior to PET/CT?

    Energy Technology Data Exchange (ETDEWEB)

    Binse, I.; Poeppel, T.D.; Ruhlmann, M.; Gomez, B.; Bockisch, A.; Rosenbaum-Krumme, S.J. [University of Duisburg-Essen, Medical Faculty, Department of Nuclear Medicine, Essen (Germany); Umutlu, L. [University of Duisburg-Essen, Medical Faculty, Department of Radiology, Essen (Germany)

    2016-06-15

    The aim of this study was to compare integrated PET/CT and PET/MRI for their usefulness in detecting and categorizing cervical iodine-positive lesions in patients with differentiated thyroid cancer using {sup 124}I as tracer. The study group comprised 65 patients at high risk of iodine-positive metastasis who underwent PET/CT (low-dose CT scan, PET acquisition time 2 min; PET/CT{sub 2}) followed by PET/MRI of the neck 24 h after {sup 124}I administration. PET images from both modalities were analysed for the numbers of tracer-positive lesions. Two different acquisition times were used for the comparisons, one matching the PET/CT{sub 2} acquisition time (2 min, PET/MRI{sub 2}) and the other covering the whole MRI scan time (30 min, PET/MRI{sub 30}). Iodine-positive lesions were categorized as metastasis, thyroid remnant or inconclusive according to their location on the PET/CT images. Morphological information provided by MRI was considered for evaluation of lesions on PET/MRI and for volume information. PET/MRI{sub 2} detected significantly more iodine-positive metastases and thyroid remnants than PET/CT{sub 2} (72 vs. 60, p = 0.002, and 100 vs. 80, p = 0.001, respectively), but the numbers of patients with at least one tumour lesion identified were not significantly different (21/65 vs. 17/65 patients). PET/MRI{sub 30} tended to detect more PET-positive metastases than PET/MRI{sub 2} (88 vs. 72), but the difference was not significant (p = 0.07). Of 21 lesions classified as inconclusive on PET/CT, 5 were assigned to metastasis or thyroid remnant when evaluated by PET/MRI. Volume information was available in 34 % of iodine-positive metastases and 2 % of thyroid remnants on PET/MRI. PET/MRI of the neck was found to be superior to PET/CT in detecting iodine-positive lesions. This was attributed to the higher sensitivity of the PET component, Although helpful in some cases, we found no substantial advantage of PET/MRI over PET/CT in categorizing iodine

  10. Imaging corn plants with PhytoPET, a modular PET system for plant biology

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.; Kross, B.; McKisson, J.; McKisson, J. E.; Weisenberger, A. G.; Xi, W.; Zorn, C.; Bonito, G.; Howell, C. R.; Reid, C. D.; Crowell, A.; Cumberbatch, L. C.; Topp, C.; Smith, M. F.

    2013-11-01

    PhytoPET is a modular positron emission tomography (PET) system designed specifically for plant imaging. The PhytoPET design allows flexible arrangements of PET detectors based on individual standalone detector modules built from single Hamamatsu H8500 position sensitive photomultiplier tubes and pixelated LYSO arrays. We have used the PhytoPET system to perform preliminary corn plant imaging studies at the Duke University Biology Department Phytotron. Initial evaluation of the PhytoPET system to image the biodistribution of the positron emitting tracer {sup 11}C in corn plants is presented. {sup 11}CO{sub 2} is loaded into corn seedlings by a leaf-labeling cuvette and translocation of {sup 11}C-sugars is imaged by a flexible arrangement of PhytoPET modules on each side. The PhytoPET system successfully images {sup 11}C within corn plants and allows for the dynamic measurement of {sup 11}C-sugar translocation from the leaf to the roots.

  11. Oncology PET imaging

    International Nuclear Information System (INIS)

    Inubushi, Masayuki

    2014-01-01

    At the beginning of this article, likening medical images to 'Where is Waldo?' I indicate the concept of diagnostic process of PET/CT imaging, so that medical physics specialists could understand the role of each imaging modality and infer our distress for image diagnosis. Then, I state the present situation of PET imaging and the basics (e.g. health insurance coverage, clinical significance, principle, protocol, and pitfall) of oncology FDG-PET imaging which accounts for more than 99% of all clinical PET examinations in Japan. Finally, I would like to give a wishful prospect of oncology PET that will expand to be more cancer-specific in order to assess therapeutic effects of emerging molecular targeted drugs targeting the 'hallmarks of cancer'. (author)

  12. [18F]FDG PET/CT outperforms [18F]FDG PET/MRI in differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Vrachimis, Alexis; Wenning, Christian; Weckesser, Matthias; Stegger, Lars; Burg, Matthias Christian; Allkemper, Thomas; Schaefers, Michael

    2016-01-01

    To evaluate the diagnostic potential of PET/MRI with [ 18 F]FDG in comparison to PET/CT in patients with differentiated thyroid cancer suspected or known to have dedifferentiated. The study included 31 thyroidectomized and remnant-ablated patients who underwent a scheduled [ 18 F]FDG PET/CT scan and were then enrolled for a PET/MRI scan of the neck and thorax. The datasets (PET/CT, PET/MRI) were rated regarding lesion count, conspicuity, diameter and characterization. Standardized uptake values were determined for all [ 18 F]FDG-positive lesions. Histology, cytology, and examinations before and after treatment served as the standards of reference. Of 26 patients with a dedifferentiated tumour burden, 25 were correctly identified by both [ 18 F]FDG PET/CT and PET/MRI. Detection rates by PET/CT and PET/MRI were 97 % (113 of 116 lesions) and 85 % (99 of 113 lesions) for malignant lesions, and 100 % (48 of 48 lesions) and 77 % (37 of 48 lesions) for benign lesions, respectively. Lesion conspicuity was higher on PET/CT for both malignant and benign pulmonary lesions and in the overall rating for malignant lesions (p < 0.001). There was a difference between PET/CT and PET/MRI in overall evaluation of malignant lesions (p < 0.01) and detection of pulmonary metastases (p < 0.001). Surgical evaluation revealed three malignant lesions missed by both modalities. PET/MRI additionally failed to detect 14 pulmonary metastases and 11 benign lesions. In patients with thyroid cancer and suspected or known dedifferentiation, [ 18 F]FDG PET/MRI was inferior to low-dose [ 18 F]FDG PET/CT for the assessment of pulmonary status. However, for the assessment of cervical status, [ 18 F]FDG PET/MRI was equal to contrast-enhanced neck [ 18 F]FDG PET/CT. Therefore, [ 18 F]FDG PET/MRI combined with a low-dose CT scan of the thorax may provide an imaging solution when high-quality imaging is needed and high-energy CT is undesirable or the use of a contrast agent is contraindicated. (orig.)

  13. Childhood Attachment to Pets: Associations between Pet Attachment, Attitudes to Animals, Compassion, and Humane Behaviour

    Directory of Open Access Journals (Sweden)

    Roxanne D. Hawkins

    2017-05-01

    Full Text Available Attachment to pets has an important role in children’s social, emotional, and cognitive development, mental health, well-being, and quality of life. This study examined associations between childhood attachment to pets and caring and friendship behaviour, compassion, and attitudes towards animals. This study also examined socio-demographic differences, particularly pet ownership and pet type. A self-report survey of over one thousand 7 to 12 year-olds in Scotland, UK, revealed that the majority of children are strongly attached to their pets, but attachment scores differ depending on pet type and child gender. Analysis revealed that attachment to pets is facilitated by compassion and caring and pet-directed friendship behaviours and that attachment to pets significantly predicts positive attitudes towards animals. The findings have implications for the promotion of prosocial and humane behaviour. Encouraging children to participate in pet care behaviour may promote attachment between children and their pet, which in turn may have a range of positive outcomes for both children (such as reduced aggression, better well-being, and quality of life and pets (such as humane treatment. This study enhances our understanding of childhood pet attachment and has implications for humane education and promoting secure emotional attachments in childhood.

  14. Selecting Safe Pets (For Parents)

    Science.gov (United States)

    ... supplies (pet bowls, pet bed, leash, etc.) as gifts, then selecting the pet as a family. That way, everyone has time to really think about whether your family is ready for a pet. Key Questions Before adopting or purchasing any pet, talk to all family members, discuss ...

  15. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis

    International Nuclear Information System (INIS)

    Jin, H.; Yuan, L.; Li, C.; Kan, Y.; Yang, J.; Hao, R.

    2014-01-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  16. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis.

    Science.gov (United States)

    Jin, H; Yuan, L; Li, C; Kan, Y; Hao, R; Yang, J

    2014-03-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  17. Clinical Applications of FDG PET and PET/CT in Head and Neck Cancer

    Directory of Open Access Journals (Sweden)

    Akram Al-Ibraheem

    2009-01-01

    Full Text Available 18F-FDG PET plays an increasing role in diagnosis and management planning of head and neck cancer. Hybrid PET/CT has promoted the field of molecular imaging in head and neck cancer. This modality is particular relevant in the head and neck region, given the complex anatomy and variable physiologic FDG uptake patterns. The vast majority of 18F-FDG PET and PET/CT applications in head and neck cancer related to head and neck squamous cell carcinoma. Clinical applications of 18F-FDG PET and PET/CT in head and neck cancer include diagnosis of distant metastases, identification of synchronous 2nd primaries, detection of carcinoma of unknown primary and detection of residual or recurrent disease. Emerging applications are precise delineation of the tumor volume for radiation treatment planning, monitoring treatment, and providing prognostic information. The clinical role of 18F-FDG PET/CT in N0 disease is limited which is in line with findings of other imaging modalities. MRI is usually used for T staging with an intense discussion concerning the preferable imaging modality for regional lymph node staging as PET/CT, MRI, and multi-slice spiral CT are all improving rapidly. Is this review, we summarize recent literature on 18F-FDG PET and PET/CT imaging of head and neck cancer.

  18. PET/CT imaging of human somatostatin receptor 2 (hsstr2) as reporter gene for gene therapy

    International Nuclear Information System (INIS)

    Hofmann, M.; Gazdhar, A.; Weitzel, T.; Schmid, R.; Krause, T.

    2006-01-01

    Localized information on region-selective gene expression in small animals is widely obtained by use of reporter genes inducing light emission. Using these reporter genes for imaging deep inside the human body fluorescent probes are hindered by attenuation, scattering and possible fluorescence quenching. This can be overcome by use of radio-peptide receptors as reporter genes. Therefore, the feasibility of the somatostatin receptor 2 expression vector system for expression imaging was checked against a control vector containing luciferase gene. For in vivo transduction of vector DNA into the rat forelimb muscles the in vivo electroporation technique was chosen because of its high regio-selectivity. The gene expression was imaged by high-sensitive CCD camera (luciferase activity) and by PET/CT using a Ga-68-DOTATOC as radio peptide probe. The relative sstr2 expression was enhanced by gene transduction at maximum to a factor of 15. The PET/CT images could be fully quantified. The above demonstrated feasibility of radio-peptide PET/CT reporter gene imaging may serve in the future as a tool for full quantitative understanding of regional gene expression, especially in large animals and humans

  19. PET/CT imaging of human somatostatin receptor 2 (hsstr2) as reporter gene for gene therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, M. [Molecular Imaging and Therapy Group (MIT-Bern), Clinic of Nuclear Medicine, Inselspital, Medical School Bern (Switzerland)]. E-mail: Michael.Hofmann@insel.ch; Gazdhar, A. [Division of Pulmonary Medicine, University Hospital Bern (Switzerland); Weitzel, T. [Molecular Imaging and Therapy Group (MIT-Bern), Clinic of Nuclear Medicine, Inselspital, Medical School Bern (Switzerland); Schmid, R. [Division of Thoracic Surgery, University Hospital Bern (Switzerland); Krause, T. [Molecular Imaging and Therapy Group (MIT-Bern), Clinic of Nuclear Medicine, Inselspital, Medical School Bern (Switzerland)

    2006-12-20

    Localized information on region-selective gene expression in small animals is widely obtained by use of reporter genes inducing light emission. Using these reporter genes for imaging deep inside the human body fluorescent probes are hindered by attenuation, scattering and possible fluorescence quenching. This can be overcome by use of radio-peptide receptors as reporter genes. Therefore, the feasibility of the somatostatin receptor 2 expression vector system for expression imaging was checked against a control vector containing luciferase gene. For in vivo transduction of vector DNA into the rat forelimb muscles the in vivo electroporation technique was chosen because of its high regio-selectivity. The gene expression was imaged by high-sensitive CCD camera (luciferase activity) and by PET/CT using a Ga-68-DOTATOC as radio peptide probe. The relative sstr2 expression was enhanced by gene transduction at maximum to a factor of 15. The PET/CT images could be fully quantified. The above demonstrated feasibility of radio-peptide PET/CT reporter gene imaging may serve in the future as a tool for full quantitative understanding of regional gene expression, especially in large animals and human000.

  20. Routes for the production of isotopes for PET with high intensity deuteron accelerators

    Science.gov (United States)

    Arias de Saavedra, F.; Porras, I.; Praena, J.

    2018-04-01

    Recent advances in accelerator science are opening new possibilities in different fields of physics. In particular, the development of compact linear accelerators that can provide charged particles of low-medium energy (few MeV) with high current (above mA) allows for the study of new possibilities in neutron production and for new routes for the production of radioisotopes. Keeping in mind how radioisotopes are actually produced in dedicated facilities, we have performed a study of alternative reactions to produce PET isotopes induced by low-energy deuterons. We have fitted the EXFOR cross sections data, used the fitted values of the stopping power by Andersen and Ziegler and calculated by numerical integration the production rate of isotopes for charged particles up to 20 MeV. The results for deuterons up to 3 MeV are compared with the ones from cyclotrons, which are able to provide higher energies to the charged projectiles but with lower intensities. Our results indicate that using linear accelerators may be a good alternative for producing PET isotopes, reducing the problem of neutron activation.